WorldWideScience

Sample records for transient electro-osmotic flow

  1. Electro-osmotic flows inside triangular microchannels

    International Nuclear Information System (INIS)

    Vocale, P; Spiga, M; Geri, M; Morini, G L

    2014-01-01

    This work presents a numerical investigation of both pure electro-osmotic and combined electro-osmotic/pressure-driven flows inside triangular microchannels. A finite element analysis has been adopted to solve the governing equations for the electric potential and the velocity field, accounting for a finite thickness of the electric double layer. The influence of non-dimensional parameters such as the aspect ratio of the cross-section, the electrokinetic diameter and the ratio of the pressure force to the electric force on the flow behavior has been investigated. Numerical results point out that the velocity field is significantly influenced by the aspect ratio of the cross section and the electrokinetic diameter. More specifically, the aspect ratio plays an important role in determining the maximum volumetric flow rate, while the electrokinetic diameter is crucial to establishing the range of pressures that may be sustained by the electro-osmotic flow. Numerical results are also compared with two correlations available in the literature which enable to assess the volumetric flow rate and the pressure head for microchannels featuring a rectangular, a trapezoidal or an elliptical cross-section.

  2. Analytical and numerical study of the electro-osmotic annular flow of viscoelastic fluids.

    Science.gov (United States)

    Ferrás, L L; Afonso, A M; Alves, M A; Nóbrega, J M; Pinho, F T

    2014-04-15

    In this work we present semi-analytical solutions for the electro-osmotic annular flow of viscoelastic fluids modeled by the Linear and Exponential PTT models. The viscoelastic fluid flows in the axial direction between two concentric cylinders under the combined influences of electrokinetic and pressure forcings. The analysis invokes the Debye-Hückel approximation and includes the limit case of pure electro-osmotic flow. The solution is valid for both no slip and slip velocity at the walls and the chosen slip boundary condition is the linear Navier slip velocity model. The combined effects of fluid rheology, electro-osmotic and pressure gradient forcings on the fluid velocity distribution are also discussed. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Hydrodynamic dispersion of a reactive solute in Electro-Osmotic flow ...

    African Journals Online (AJOL)

    The objective of this paper is to study the effect of the dispersion coefficients and the reaction parameter on the hydrodynamic dispersion of a reactive solute in electro-osmotic flow through the method of finite elements using quadratic Lagrange polynomials. Journal of the Nigerian Association of Mathematical Physics Vol.

  4. Electro-osmotic flow of couple stress fluids in a micro-channel propagated by peristalsis

    Science.gov (United States)

    Tripathi, Dharmendra; Yadav, Ashu; Anwar Bég, O.

    2017-04-01

    A mathematical model is developed for electro-osmotic peristaltic pumping of a non-Newtonian liquid in a deformable micro-channel. Stokes' couple stress fluid model is employed to represent realistic working liquids. The Poisson-Boltzmann equation for electric potential distribution is implemented owing to the presence of an electrical double layer (EDL) in the micro-channel. Using long wavelength, lubrication theory and Debye-Huckel approximations, the linearized transformed dimensionless boundary value problem is solved analytically. The influence of electro-osmotic parameter (inversely proportional to Debye length), maximum electro-osmotic velocity (a function of external applied electrical field) and couple stress parameter on axial velocity, volumetric flow rate, pressure gradient, local wall shear stress and stream function distributions is evaluated in detail with the aid of graphs. The Newtonian fluid case is retrieved as a special case with vanishing couple stress effects. With increasing the couple stress parameter there is a significant increase in the axial pressure gradient whereas the core axial velocity is reduced. An increase in the electro-osmotic parameter both induces flow acceleration in the core region (around the channel centreline) and it also enhances the axial pressure gradient substantially. The study is relevant in the simulation of novel smart bio-inspired space pumps, chromatography and medical micro-scale devices.

  5. Separation of ions in nanofluidic channels with combined pressure-driven and electro-osmotic flow.

    Science.gov (United States)

    Gillespie, Dirk; Pennathur, Sumita

    2013-03-05

    Separation of ionic species with the same electrophoretic mobility but different valence in electrolyte systems can occur within nanometer-scale channels with finite electrical double layers (EDLs). This is because EDL thicknesses are a significant fraction of slit height in such channels and can create transverse analyte concentration profiles that allow for unique separation modalities when combined with axial fluid flow. Previous work has shown such separation to occur using either pressure-driven flow or electro-osmotic flow separately. Here, we develop a Poisson-Boltzmann model to compare the separation of such ions using the combination of both pressure-driven and electro-osmotic flow. Applying a pressure gradient in the opposite direction of electro-osmotic flow can allow for zero or infinite retention of analyte species, which we investigate using three different wall boundary conditions. Furthermore, we determine conditions in fused silica nanochannels with which to generate optimal separation between two analytes of different charge but the same mobility. We also give simple rules of thumb to achieve the best separation efficacy in nanochannel systems.

  6. Microfluidic analogy of the wheatstone bridge for systematic investigations of electro-osmotic flows.

    Science.gov (United States)

    Plecis, Adrien; Chen, Yong

    2008-05-15

    A microfluidic analogy of the electric Wheatstone Bridge has been developed for electrokinetic study of miscellaneous liquid-solid interfaces. By using an optimized glass-PDMS-glass device technology, microfluidic channels with well-controlled surface properties can be fabricated, forming an "H" shaped fluidic network. After solving a set of linear equations, the electro-osmotic flow rate in the center channel can be deduced from indirect measurement of flow rates in the lateral channels. Experimentally, we demonstrate that the electro-osmotic mobility can be monitored every 30 s with accuracy better than 3% for a large dynamic range of electric fields. The results obtained with a borosilicate glass (D-263) and several standard biological buffers are also shown to illustrate the capability of this high throughput method.

  7. A microfluidic chip for blood plasma separation using electro-osmotic flow control

    International Nuclear Information System (INIS)

    Jiang, Hai; Weng, Xuan; Chon, Chan Hee; Wu, Xudong; Li, Dongqing

    2011-01-01

    In this paper, a microfluidic-based chip with two straight microchannels and five branch microchannels was designed and tested to separate blood plasma from a small sample of fresh human blood. The electro-osmotic flow method was used to control the separation of blood plasma. Blood cell removal and blood plasma extraction were realized in experiments. The efficiency of extracting blood plasma can be as high as 26%

  8. Electro-osmotic flow through a thin channel with gradually varying wall potential and hydrodynamic slippage

    International Nuclear Information System (INIS)

    Ng Chiuon; Zhou Qi

    2012-01-01

    The lubrication approximation is applied to electro-osmotic flow through a thin parallel-plate channel under the combined effect of charge and hydrodynamic slippage modulation on the walls. The walls are periodically patterned for the charge and slip distributions, with a wavelength much longer than the channel height. It is shown that the phase of the wall patterns will play a significant role in determining the section-averaged velocity as well as the local convection pattern, both quantitatively and qualitatively. The effect of the phase on the flow will be dramatically different, depending on whether the electric field is applied along or perpendicular to the varying direction of the patterns. The possibility of generating a net flow in a direction perpendicular to the applied field is demonstrated. (paper)

  9. Non-steady electro-osmotic flow of a micropolar fluid in a microchannel

    International Nuclear Information System (INIS)

    Siddiqui, Abuzar A; Lakhtakia, Akhlesh

    2009-01-01

    We formulated the initial-boundary-value problem of non-steady electro-osmotic flow of a micropolar fluid in a rectangular microchannel of height much larger than the Debye length and length much larger the height. Solving the governing differential equations numerically when a spatially uniform electric field is applied as an impulse of finite magnitude, we found that the effect is instantaneous on the flow, just as for simple Newtonian fluids. The decay times of the fluid velocity and the microrotation, however, are smaller in micropolar fluids than in simple Newtonian fluids. The maximum magnitude of microrotation decreases as the micropolarity increases. The effect of microrotation on the stress tensor is more dominant than that of the fluid speed, and a threshold effect with respect to the magnitude of the zeta potential is evident in the spatial profile of the couple stress tensor. We expect similar trends even when the applied electric field varies over some finite interval of time.

  10. Electro-osmotic flow through nanopores in thin and ultrathin membranes

    Science.gov (United States)

    Melnikov, Dmitriy V.; Hulings, Zachery K.; Gracheva, Maria E.

    2017-06-01

    We theoretically study how the electro-osmotic fluid velocity in a charged cylindrical nanopore in a thin solid state membrane depends on the pore's geometry, membrane charge, and electrolyte concentration. We find that when the pore's length is comparable to its diameter, the velocity profile develops a concave shape with a minimum along the pore axis unlike the situation in very long nanopores with a maximum velocity along the central pore axis. This effect is attributed to the induced pressure along the nanopore axis due to the fluid flow expansion and contraction near the exit or entrance to the pore and to the reduction of electric field inside the nanopore. The induced pressure is maximal when the pore's length is about equal to its diameter while decreasing for both longer and shorter nanopores. A model for the fluid velocity incorporating these effects is developed and shown to be in a good agreement with numerically computed results.

  11. Non-isothermal electro-osmotic flow in a microchannel with charge-modulated surfaces

    Science.gov (United States)

    Bautista, Oscar; Sanchez, Salvador; Mendez, Federico

    2015-11-01

    In this work, we present an theoretical analysis of a nonisothermal electro-osmotic flow of a Newtonian fluid over charge-modulated surfaces in a microchannel. Here, the heating in the microchannel is due to the Joule effect caused by the imposition of an external electric field. The study is conducted through the use of perturbation techniques and is validated by means of numerical simulations. We consider that both, viscosity and electrical conductivity of the fluid are temperature-dependent; therefore, in order to determine the heat transfer process and the corresponding effects on the flow field, the governing equations of continuity, momentum, energy and electric potential have to be solved in a coupled manner. The principal obtained results evidence that the flow patterns are perturbed in a noticeable manner in comparison with the isothernal case. Our results may be used for increasing microfluidics mixing by conjugating thermal effects with the use of charge-modulated surfaces. This work has been supported by the research grants no. 220900 of Consejo Nacional de Ciencia y Tecnología (CONACYT) and 20150919 of SIP-IPN at Mexico. F. Méndez acknowledges also the economical support of PAPIIT-UNAM under contract number IN112215.

  12. Combining Electro-Osmotic Flow and FTA® Paper for DNA Analysis on Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ryan Wimbles

    2016-07-01

    Full Text Available FTA® paper can be used to protect a variety of biological samples prior to analysis, facilitating ease-of-transport to laboratories or long-term archive storage. The use of FTA® paper as a solid phase eradicates the need to elute the nucleic acids from the matrix prior to DNA amplification, enabling both DNA purification and polymerase chain reaction (PCR-based DNA amplification to be performed in a single chamber on the microfluidic device. A disc of FTA® paper, containing a biological sample, was placed within the microfluidic device on top of wax-encapsulated DNA amplification reagents. The disc containing the biological sample was then cleaned up using Tris-EDTA (TE buffer, which was passed over the disc, via electro-osmotic flow, in order to remove any potential inhibitors of downstream processes. DNA amplification was successfully performed (from buccal cells, whole blood and semen using a Peltier thermal cycling system, whereupon the stored PCR reagents were released during the initial denaturing step due to the wax barrier melting between the FTA® disc and PCR reagents. Such a system offers advantages in terms of a simple sample introduction interface and the ability to process archived samples in an integrated microfluidic environment with minimal risk of contamination.

  13. Effects of Micromachining Processes on Electro-Osmotic Flow Mobility of Glass Surfaces

    Directory of Open Access Journals (Sweden)

    Norihisa Miki

    2013-03-01

    Full Text Available Silica glass is frequently used as a device material for micro/nano fluidic devices due to its excellent properties, such as transparency and chemical resistance. Wet etching by hydrofluoric acid and dry etching by neutral loop discharge (NLD plasma etching are currently used to micromachine glass to form micro/nano fluidic channels. Electro-osmotic flow (EOF is one of the most effective methods to drive liquids into the channels. EOF mobility is affected by a property of the micromachined glass surfaces, which includes surface roughness that is determined by the manufacturing processes. In this paper, we investigate the effect of micromaching processes on the glass surface topography and the EOF mobility. We prepared glass surfaces by either wet etching or by NLD plasma etching, investigated the surface topography using atomic force microscopy, and attempted to correlate it with EOF generated in the micro-channels of the machined glass. Experiments revealed that the EOF mobility strongly depends on the surface roughness, and therefore upon the fabrication process used. A particularly strong dependency was observed when the surface roughness was on the order of the electric double layer thickness or below. We believe that the correlation described in this paper can be of great help in the design of micro/nano fluidic devices.

  14. Suppression of ion conductance by electro-osmotic flow in nano-channels with weakly overlapping electrical double layers

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2016-08-01

    Full Text Available This theoretical study investigates the nonlinear ionic current-voltage characteristics of nano-channels that have weakly overlapping electrical double layers. Numerical simulations as well as a 1-D mathematical model are developed to reveal that the electro-osmotic flow (EOF interplays with the concentration-polarization process and depletes the ion concentration inside the channels, thus significantly suppressing the channel conductance. The conductance may be restored at high electrical biases in the presence of recirculating vortices within the channels. As a result of the EOF-driven ion depletion, a limiting-conductance behavior is identified, which is intrinsically different from the classical limiting-current behavior.

  15. Electro-osmotic and pressure-driven flow of viscoelastic fluids in microchannels: Analytical and semi-analytical solutions

    Science.gov (United States)

    Ferrás, L. L.; Afonso, A. M.; Alves, M. A.; Nóbrega, J. M.; Pinho, F. T.

    2016-09-01

    In this work, we present a series of solutions for combined electro-osmotic and pressure-driven flows of viscoelastic fluids in microchannels. The solutions are semi-analytical, a feature made possible by the use of the Debye-Hückel approximation for the electrokinetic fields, thus restricted to cases with small electric double-layers, in which the distance between the microfluidic device walls is at least one order of magnitude larger than the electric double-layer thickness. To describe the complex fluid rheology, several viscoelastic differential constitutive models were used, namely, the simplified Phan-Thien-Tanner model with linear, quadratic or exponential kernel for the stress coefficient function, the Johnson-Segalman model, and the Giesekus model. The results obtained illustrate the effects of the Weissenberg number, the Johnson-Segalman slip parameter, the Giesekus mobility parameter, and the relative strengths of the electro-osmotic and pressure gradient-driven forcings on the dynamics of these viscoelastic flows.

  16. Electro-osmotically actuated oscillatory flow of a physiological fluid on a porous microchannel subject to an external AC electric field having dissimilar frequencies

    Science.gov (United States)

    Misra, Jagadis C.; Chandra, Sukumar

    2014-04-01

    Electro-osmotic flow of a physiological fluid with prominent micropolar characteristics, flowing over a microchannel has been analyzed for a situation, where the system is subject to the action of an external AC electric field. In order to account for the rotation of the micro-particles suspended in the physiological fluid, the fluid has been treated as a micropolar fluid. The microchannel is considered to be bounded by two porous plates executing oscillatory motion. Such motion of the plates will normally induce oscillatory flow of the fluid. The governing equations of the fluid include a second-order partial differential equation depicting Gauss's law of electrical charge distributions and two other partial differential equations of second order that arise out of the laws of conservation of linear and angular momenta. These equations have been solved under the sole influence of electrokinetic forces, by using appropriate boundary conditions. This enabled us to determine explicit analytical expressions for the electro-osmotic velocity of the fluid and the microrotation of the suspended micro-particles. These expressions have been used to obtain numerical estimates of important physical variables associated with the oscillatory electro-osmotic flow of a blood sample inside a micro-bio-fluidic device. The numerical results presented in graphical form clearly indicate that the formation of an electrical double layer near the vicinity of the wall causes linear momentum to reduce. In contrast, the angular momentum increases with the enhancement of microrotation of the suspended microparticles. The study will find important applications in the validation of results of further experimental and numerical models pertaining to flow in micro-bio-fluidic devices. It will also be useful in the improvement of the design and construction of various micro-bio-fluidic devices.

  17. Transport of magneto-nanoparticles during electro-osmotic flow in a micro-tube in the presence of magnetic field for drug delivery application

    Science.gov (United States)

    Mondal, A.; Shit, G. C.

    2017-11-01

    In this paper, we have examined the motion of magnetic-nanoparticles and the flow characteristics of biofluid in a micro-tube in the presence of externally applied magnetic field and electrokinetic effects. In the drug delivery system, the motion of the magnetic nanoparticles as carriers is important for therapeutic procedure in the treatment of tumor cells, infections and removing blood clots. The unidirectional electro-osmotic flow of biofluid is driven by the combined effects of pulsatile pressure gradient and electrokinetic force. The governing equation for unsteady electromagnetohydrodynamic flow subject to the no-slip boundary condition has been solved numerically by using Crank-Nicolson implicit finite difference scheme. We have analyzed the variation of axial velocity, velocity distribution of magnetic nanoparticles, volumetric flow rate and wall shear stress for various values of the non-dimensional parameters. The study reveals that blood flow velocity, carriers velocity and flow rate are strongly influenced by the electro-osmotic parameter as well as the Hartmann number. The particle mass parameter as well as the particle concentration parameter have efficient capturing effect on magnetic nanoparticles during blood flow through a micro-tube for drug delivery.

  18. Electro-osmotic flow of power-law fluid and heat transfer in a micro-channel with effects of Joule heating and thermal radiation

    Science.gov (United States)

    Shit, G. C.; Mondal, A.; Sinha, A.; Kundu, P. K.

    2016-11-01

    A mathematical model has been developed for studying the electro-osmotic flow and heat transfer of bio-fluids in a micro-channel in the presence of Joule heating effects. The flow of bio-fluid is governed by the non-Newtonian power-law fluid model. The effects of thermal radiation and velocity slip condition have been examined in the case of hydrophobic channel. The Poisson-Boltzmann equation governing the electrical double layer field and a body force generated by the applied electric potential field are taken into consideration. The results presented here pertain to the case where the height of the channel is much greater than the thickness of electrical double layer comprising the Stern and diffuse layers. The expressions for flow characteristics such as velocity, temperature, shear stress and Nusselt number have been derived analytically under the purview of the present model. The results estimated on the basis of the data available in the existing scientific literatures are presented graphically. The effects of thermal radiation have an important bearing on the therapeutic procedure of hyperthermia, particularly in understanding the heat transfer in micro-channel in the presence of electric potential. The dimensionless Joule heating parameter has a reducing impact on Nusselt number for both pseudo-plastic and dilatant fluids, nevertheless its impact on Nusselt number is more pronounced for dilatant fluid. Furthermore, the effect of viscous dissipation has a significant role in controlling heat transfer and should not be neglected.

  19. Influence of material transition and interfacial area changes on flow and concentration in electro-osmotic flows.

    Science.gov (United States)

    Rani, Sudheer D; You, Byoung-Hee; Soper, Steve A; Murphy, Michael C; Nikitopoulos, Dimitris E

    2013-04-03

    This paper presents a numerical study to investigate the effect of geometrical and material transition on the flow and progression of a sample plug in electrokinetic flows. Three cases were investigated: (a) effect of sudden cross-sectional area change (geometrical transition or mismatch) at the interface, (b) effect of only material transition (i.e. varying ζ-potential), and (c) effect of combined material transition and cross-sectional area change at the interface. The geometric transition was quantified based on the ratio of reduced flow area A2 at the mismatch plane to the original cross-sectional area A1. Multiple simulations were performed for varying degrees of area reduction i.e. 0-75% reduction in the available flow area, and the effect of dispersion on the sample plug was quantified by standard metrics. Simulations showed that a 13% combined material and geometrical transition can be tolerated without significant loss of sample resolution. A 6.54% reduction in the flow rates was found between 0% and 75% combined material and geometrical transition. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Analysis of metal ions migration to determine electro-osmotic flow for the in-situ cleanup of a tar-contaminated site

    KAUST Repository

    Lima, Ana T.

    2012-03-01

    An electro-osmosis experiment was set up on a former asphalt factory site, which is currently contaminated by tar, in Olst, the Netherlands. The main goal of this experiment was to remove polycyclic aromatic hydrocarbons (PAHs) from a contaminated clay layer by applying an electric gradient. But before calculating PAH removal, the direction and intensity of electro-osmosis have to be estimated. In field situations, tracers are used to get information about the water flow. In the present study, the inorganic elements concentration oscillations during electro-osmosis application are used as tracers. The experiment was set up in a clay layer, with the configuration 1m×1m×0.3m, at a depth of 4m below soil surface. Al, Ca, Cl, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, P, S, Si, Ti and Zn concentrations were determined in 28 measurements and were performed during the experimental period of 159days. Then they were used in a first evaluation where auto and cross-correlations were analyzed to aid in the geochemical interpretation and select the most conservative elements. The second part of this study is devoted to estimate the migration of water based on the concentrations development of Cl - at the anode and Na + at the cathode. Electro-osmotic flow was estimated to be intense (2.9 -10 -9-2.18 -10 -8m -s -1) during the first 10 to 50days of experiment and to cease after this period. © 2012.

  1. An analysis of electro-osmotic and magnetohydrodynamic heat pipes

    International Nuclear Information System (INIS)

    Harrison, M.A.

    1988-01-01

    Mechanically simple methods of improving heat transport in heat pipes are investigated. These methods are electro-osmotic and magnetohydrodynamic augmentation. For the electro-osmotic case, a detailed electrokinetic model is used. The electrokinetic model used includes the effects of pore surface curvature and multiple ion diffusivities. The electrokinetic model is extended to approximate the effects of elevated temperature. When the electro-osmotic model is combined with a suitable heat-pipe model, it is found that the electro-osmotic pump should be a thin membrane. Arguments are provided that support the use of a volatile electrolyte. For the magnetohydrodynamic case, a brief investigation is provided. A quasi-one-dimensional hydromagnetic duct flow model is used. This hydromagnetic model is extended to approximate flow effects unique to heat pipes. When combined with a suitable heat pipe model, it is found that there is no performance gain for the case considered. In fact, there are serious pressure-distribution problems that have not been previously recognized. Potential solutions to these pressure-distribution problems are suggested

  2. Electro-osmotic pumping of sodium chloride solutions

    CSIR Research Space (South Africa)

    Schoeman, JJ

    1997-08-20

    Full Text Available Electro-osmotic pumping (EOP) theory and its characteristics (transport numbers, brine concentration, current density, current efficiency, electro-osmotic coefficients, etc.) of Selemion AMV and CMV ion-exchange membranes were studied. The brine...

  3. Augmentation of peristaltic microflows through electro-osmotic mechanisms

    International Nuclear Information System (INIS)

    Chakraborty, Suman

    2006-01-01

    The present work aims to theoretically establish that the employment of an axial electric field can substantially augment the rate of microfluidic transport occurring in peristaltic microtubes. For theoretical analysis, shape evolution of the tube is taken to be arbitrary, except for the fact that the characteristic wavelength is assumed to be significantly greater than the average radius of cross section. First, expressions for the velocity profile within the tube are derived and are subsequently utilized to obtain variations in the net flow rate across the same, as a function of the pertinent system parameters. Subsequently, the modes of interaction between the electro-osmotic and peristaltic mechanisms are established through the variations in the time-averaged flow rates for zero pressure rise and the pressure rise for zero time-averaged flow rates, as expressed in terms of the occlusion number, characteristic electro-osmotic velocity and the peristaltic wave speed. From the simulation predictions, it is suggested that a judicious combination of peristalsis and an axial electrokinetic body force can drastically enhance the time-averaged flow rate, provided that the occlusion number is relatively small

  4. Topology and shape optimization of induced-charge electro-osmotic micropumps

    DEFF Research Database (Denmark)

    Gregersen, Misha Marie; Okkels, Fridolin; Bazant, M. Z.

    2009-01-01

    For a dielectric solid surrounded by an electrolyte and positioned inside an externally biased parallel-plate capacitor, we study numerically how the resulting induced-charge electro-osmotic (ICEO) flow depends on the topology and shape of the dielectric solid. In particular, we extend existing...... the net induced electro-osmotic flow rate through the electrolytic capacitor in the direction parallel to the capacitor plates. Once found, the performance of the topology-optimized geometries has been validated by transferring them to conventional electrokinetic models not relying on the artificial...

  5. Development of an electro-osmotic heat pump

    NARCIS (Netherlands)

    Stoel, J.P. van der; Oostendorp, P.A.

    1999-01-01

    The majority of heat pumps and refrigerators is driven by a mechanical compressor. Although they usually function very well, the search for new and in some cases better heat pumping concepts continues. One of the topics in this field is the development of an electro-osmotic heat pump. As each

  6. Intravesical electro-osmotic administration of mitomycin C.

    Science.gov (United States)

    Di Stasi, Savino M; Verri, Cristian; Celestino, Francesco; De Carlo, Francesco; Pagliarulo, Vincenzo

    2016-10-04

    Bladder cancer is very common and most cases are diagnosed as nonmuscle invasive disease, which is characterized by its propensity to recur and progress. Intravesical therapy is used to delay recurrence and progression, while cystectomy is reserved for patients who are refractory to transurethral resection and intravesical therapy. There is an increasing interest in methods to enhance the delivery of intravesical chemotherapeutic agents to improve efficacy. In vitro and in vivo studies demonstrated that electro-osmosis of mitomycin C (MMC) is more effective in delivering this drug into the urothelium, lamina propria, and superficial muscle layers of the bladder wall than is passive transport. Higher MMC tissue concentrations might have a clinical impact in the treatment of nonmuscle invasive bladder cancer (NMIBC). In randomized trials, intravesical electro-osmotic MMC was associated with superior response rate in high-risk NMIBC cancer, compared with passive diffusion MMC transport. New strategies such as intravesical Bacillus Calmette-Guerin (BCG) combined with electro-osmotic MMC as well as intravesical pre-operative electro-osmotic MMC provided promising results in terms of higher remission rates and longer remission times.Device-assisted intravesical chemotherapy may be a useful ancillary procedure in the treatment of NMIBC. Its evaluation must be planned with respect to the technical functioning of equipment and their use for a clear purpose to avoid the financial and human costs associated with incorrect therapies.

  7. Electro-Osmotic Pulse (EOP) Technology for Control of Water Seepage in Concrete Structures

    National Research Council Canada - National Science Library

    McInerney, Michael

    2002-01-01

    ..."). A commercial system that uses electro-osmotic pulse (EOP) technology within concrete structures offers an alternative to the trench-and-drain approach that can mitigate water-related problems from the interior (negative side...

  8. Zig-zag arrangement of four electrodes for ac electro-osmotic micropumps.

    Science.gov (United States)

    Hrdlička, J; Cervenka, P; Přibyl, M; Snita, D

    2011-07-01

    This paper deals with the mathematical modeling of traveling-wave ac electro-osmotic micropumps with a zig-zag arrangement of microelectrodes. A mathematical model based on the Poisson-Nernst-Planck-Navier-Stokes description is used in this study within the physically relevant ranges of the model parameters. We present an extensive set of parametrical studies concerning the dependence of the net velocity on a variety of parameters. We also demonstrate limits of the validity of the commonly used Capacitor-Resistor-Capacitor model. In order to achieve high net velocities, we found that there are the optimal values of the electrode length, the shift between the top and bottom electrode arrays, and the signal frequency. Performance of the zig-zag micropumps is evaluated by the means of back-pressure loads. The suggested zig-zag design brings two main benefits: (i) it allows an easier construction of four-phase traveling-wave micropumps without the need of spatially complicated electrode connections, and (ii) the zig-zag pumps can provide higher flow rates than those with single-sided coplanar arrangements. Another robust feature of the proposed zig-zag system is that a single flow reversal is observed at the ac frequency approximately six times higher than the reciprocal resistor-capacitor time even in low-amplitude regimes.

  9. Fabrication of a novel cascade high-pressure electro-osmotic pump.

    Science.gov (United States)

    Zhang, Feifang; Wang, Rong; Han, Tingting; Yang, Bingcheng; Liang, Xinmiao

    2011-07-07

    A novel cascade electro-osmotic pump (EOP) has been fabricated by alternately connecting a cation monolithic column and anion monolithic column in series. In this manner, the change of electric polarity between each stage of the cascade EOP is easily achieved and the pressure output of the EOP could be greatly enhanced without increase of the applied voltage.

  10. Numerical simulation of electro-osmotic consolidation coupling non-linear variation of soil parameters

    Science.gov (United States)

    Wu, Hui; Hu, Liming; Wen, Qingbo

    2017-06-01

    Electro-osmotic consolidation is an effective method for soft ground improvement. A main limitation of previous numerical models on this technique is the ignorance of the non-linear variation of soil parameters. In the present study, a multi-field numerical model is developed with the consideration of the non-linear variation of soil parameters during electro-osmotic consolidation process. The numerical simulations on an axisymmetric model indicated that the non-linear variation of soil parameters showed remarkable impact on the development of the excess pore water pressure and degree of consolidation. A field experiment with complex geometry, boundary conditions, electrode configuration and voltage application was further simulated with the developed numerical model. The comparison between field and numerical data indicated that the numerical model coupling of the non-linear variation of soil parameters gave more reasonable results. The developed numerical model is capable to analyze engineering cases with complex operating conditions.

  11. Electro-osmotic capture and ionic discrimination of peptide and protein biomarkers with FraC nanopores.

    Science.gov (United States)

    Huang, Gang; Willems, Kherim; Soskine, Misha; Wloka, Carsten; Maglia, Giovanni

    2017-10-16

    Biological nanopores are nanoscale sensors employed for high-throughput, low-cost, and long read-length DNA sequencing applications. The analysis and sequencing of proteins, however, is complicated by their folded structure and non-uniform charge. Here we show that an electro-osmotic flow through Fragaceatoxin C (FraC) nanopores can be engineered to allow the entry of polypeptides at a fixed potential regardless of the charge composition of the polypeptide. We further use the nanopore currents to discriminate peptide and protein biomarkers from 25 kDa down to 1.3 kDa including polypeptides differing by one amino acid. On the road to nanopore proteomics, our findings represent a rationale for amino-acid analysis of folded and unfolded polypeptides with nanopores.Biological nanopore-based protein sequencing and recognition is challenging due to the folded structure or non-uniform charge of peptides. Here the authors show that engineered FraC nanopores can overcome these problems and recognize biomarkers in the form of oligopeptides, polypeptides and folded proteins.

  12. Transient two-phase flow

    International Nuclear Information System (INIS)

    Hsu, Y.Y.

    1974-01-01

    The following papers related to two-phase flow are summarized: current assumptions made in two-phase flow modeling; two-phase unsteady blowdown from pipes, flow pattern in Laval nozzle and two-phase flow dynamics; dependence of radial heat and momentum diffusion; transient behavior of the liquid film around the expanding gas slug in a vertical tube; flooding phenomena in BWR fuel bundles; and transient effects in bubble two-phase flow. (U.S.)

  13. Electro-osmotic-based catholyte production by Microbial Fuel Cells for carbon capture.

    Science.gov (United States)

    Gajda, Iwona; Greenman, John; Melhuish, Chris; Santoro, Carlo; Li, Baikun; Cristiani, Pierangela; Ieropoulos, Ioannis

    2015-12-01

    In Microbial Fuel Cells (MFCs), the recovery of water can be achieved with the help of both active (electro-osmosis), and passive (osmosis) transport pathways of electrolyte through the semi-permeable selective separator. The electrical current-dependent transport, results in cations and electro-osmotically dragged water molecules reaching the cathode. The present study reports on the production of catholyte on the surface of the cathode, which was achieved as a direct result of electricity generation using MFCs fed with wastewater, and employing Pt-free carbon based cathode electrodes. The highest pH levels (>13) of produced liquid were achieved by the MFCs with the activated carbon cathodes producing the highest power (309 μW). Caustic catholyte formation is presented in the context of beneficial cathode flooding and transport mechanisms, in an attempt to understand the effects of active and passive diffusion. Active transport was dominant under closed circuit conditions and showed a linear correlation with power performance, whereas osmotic (passive) transport was governing the passive flux of liquid in open circuit conditions. Caustic catholyte was mineralised to a mixture of carbonate and bicarbonate salts (trona) thus demonstrating an active carbon capture mechanism as a result of the MFC energy-generating performance. Carbon capture would be valuable for establishing a carbon negative economy and environmental sustainability of the wastewater treatment process. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. [Magnetic Fe₃O₄Microparticles Conditioning-Pressure Electro-osmotic Dewatering (MPEOD) of Sewage Sludge].

    Science.gov (United States)

    Qian, Xu; Wang, Yi-li; Zhao, Li

    2016-05-15

    For magnetic Fe₃O₄ microparticles conditioning--pressure electro-osmotic dewatering (MPEOD) process of activated sludge (AS), the effects of operating parameters (optimal dosage of Fe₃O₄, electric field duration, mechanical pressure and voltage) on the dewatering efficiency and energy consumption were investigated, and the optimal conditions were determined. Moreover, the properties of supernatant and sludge along MPEOD process were studied as well as the interaction force between the sludge biosolids. Taking the energy consumption into consideration, the results showed that the optimal dewatering effect for AS could be achieved with a magnetic Fe₃O₄ microparticles dosage of 0.15 g · g⁻¹, an electric field duration of 2 h, a mechanical pressure of 400-600 kPa and a voltage of 30-50 V. When MPEOD was conducted at 400 kPa and 50 V for 2 h, the sludge reduction rate reached 98.30%, the percentage of water removal was 99.34% and the moisture content of AS decreased from 99.18% to 44.46%. The corresponding consumption of energy was 0.013 3 kW · h · kg⁻¹. The coagulation mechanism played a slight role in the AS conditioning with magnetic Fe₃O₄ micro-particles. In fact, magnetic Fe₃O₄micro-particles could greatly decrease the acid-base interaction (WA) between AS biosolids, cause floc growth and enlarge pores in AS aggregates, which will be beneficial to AS dewatering. Compared to DLVO theory, the extended DLVO theory could accurately describe the aggregation and dispersion behavior of sludge particles.

  15. Large scale micro-photometry for high resolution pH-characterization during electro-osmotic pumping and modular micro-swimming

    Science.gov (United States)

    Niu, Ran; Khodorov, Stanislav; Weber, Julian; Reinmüller, Alexander; Palberg, Thomas

    2017-11-01

    Micro-fluidic pumps as well as artificial micro-swimmers are conveniently realized exploiting phoretic solvent flows based on local gradients of temperature, electrolyte concentration or pH. We here present a facile micro-photometric method for monitoring pH gradients and demonstrate its performance and scope on different experimental situations including an electro-osmotic pump and modular micro-swimmers assembled from ion exchange resin beads and polystyrene colloids. In combination with the present microscope and DSLR camera our method offers a 2 μm spatial resolution at video frame rate over a field of view of 3920 × 2602 μm2. Under optimal conditions we achieve a pH-resolution of 0.05 with about equal contributions from statistical and systematical uncertainties. Our quantitative micro-photometric characterization of pH gradients which develop in time and reach out several mm is anticipated to provide valuable input for reliable modeling and simulations of a large variety of complex flow situations involving pH-gradients including artificial micro-swimmers, microfluidic pumping or even electro-convection.

  16. Numerical solution of transient viscoelastic flow

    DEFF Research Database (Denmark)

    Hassager, Ole; Rasmussen, Henrik K.; Szabo, Peter

    1996-01-01

    A number of applications of the Lagrangina kinematic specification in the simulation of transient viscoelastic flows are shown.......A number of applications of the Lagrangina kinematic specification in the simulation of transient viscoelastic flows are shown....

  17. EFFECT OF AQUEOUS PHASE PROPERTIES ON CLAY PARTICLE ZETA POTENTIAL AND ELECTRO-OSMOTIC PERMEABILITY: IMPLICATIONS FOR ELECTRO-KINETIC SOIL REMEDIATION PROCESSES

    Science.gov (United States)

    The influence of aqueous phase properties (pH, ionic strength and divalent metal ion concentration) on clay particle zeta potential and packed-bed electro-osmotic permeability was quantified. Although pH strongly altered the zeta potential of a Georgia kaolinite, it did not signi...

  18. Capillary filling under electro-osmotic effects in the presence of electromagneto-hydrodynamic effects

    Science.gov (United States)

    Desai, Nikhil; Ghosh, Uddipta; Chakraborty, Suman

    2014-06-01

    We report various regimes of capillary filling dynamics under electromagneto-hydrodynamic interactions, in the presence of electrical double layer effects. Our chosen configuration considers an axial electric field and transverse magnetic field acting on an electrolyte. We demonstrate that for positive interfacial potential, the movement of the capillary front resembles capillary rise in a vertical channel under the action of gravity. We also evaluate the time taken by the capillary front to reach the final equilibrium position for positive interfacial potential and show that the presence of a transverse magnetic field delays the time of travel of the liquid front, thereby sustaining the capillary motion for a longer time. Our scaling estimates reveal that the initial linear regime starts, as well as ends, much earlier in the presence of electrical and magnetic body forces, as compared to the corresponding transients observed under pure surface tension driven flow. We further obtain a long time solution for the capillary imbibition for positive interfacial potential, and derive a scaling estimate of the capillary stopping time as a function of the applied magnetic field and an intrinsic length scale delineating electromechanical influences of the electrical double layer. Our findings are likely to offer alternative strategies of controlling dynamical features of capillary imbibition, by modulating the interplay between electromagnetic interactions, electrical double layer phenomena, and hydrodynamics over interfacial scales.

  19. Transient burnout in flow reduction condition

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Kuroyanagi, Toshiyuki

    1981-01-01

    A transient flow reduction burnout experiment was conducted with water in a uniformly heated, vertically oriented tube. Test pressures ranged from 0.5 to 3.9 MPa. An analytical method was developed to obtain transient burnout conditions at the exit. A simple correlation to predict the deviation of the transient burnout mass velocity at the tube exit from the steady state mass velocity obtained as a function of steam-water density ratio and flow reduction rate. The correlation was also compared with the other data. (author)

  20. Transient response in granular bounded heap flows

    Science.gov (United States)

    Xiao, Hongyi; Ottino, Julio M.; Lueptow, Richard M.; Umbanhowar, Paul B.

    2017-11-01

    Heap formation, a canonical granular flow, is common in industry and is also found in nature. Here, we study the transition between steady flow states in quasi-2D bounded heaps by suddenly changing the feed rate from one fixed value to another. During the transition, in both experiments and discrete element method simulations, an additional wedge of flowing particles propagates over the rising free surface. The downstream edge of the wedge - the wedge front - moves downstream with velocity inversely proportional to the square root of time. An additional longer duration transient process continues after the wedge front reaches the downstream wall. The transient flux profile during the entire transition is well modeled by a diffusion-like equation derived from local mass balance and a local linear relation between the flux and the surface slope. Scalings for the transient kinematics during the flow transitions are developed based on the flux profiles. Funded by NSF Grant CBET-1511450.

  1. Simulation of Transient Viscoelastic Flow

    DEFF Research Database (Denmark)

    Rasmussen, Henrik Koblitz; Hassager, Ole

    1993-01-01

    The Lagrangian kinematic description is used to develop a numerical method for simulation of time-dependent flow of viscoelastic fluids described by integral models. The method is shown to converge to first order in the time step and at least second order in the spatial discretization. The method...

  2. Coupled equations for transient water flow, heat flow, and ...

    Indian Academy of Sciences (India)

    presented on coupled equations from a perspective of energy optimization. 1. Introduction. Given an appropriate time scale, all earth systems are transient. The evolution of the earth's crust ... tem, in combination with transient heat flow and three-dimensional deformation. .... hydraulic capacity by analogy with heat capacity.

  3. Transient Non-Newtonian Screw Flow

    Science.gov (United States)

    Ashrafi, Nariman

    2013-03-01

    The influence of axial flow on the transient response of the pseudoplastic rotating flow is carried out. The fluid is assumed to follow the Carreau-Bird model and mixed boundary conditions are imposed. The four-dimensional low-order dynamical system, resulted from Galerkin projection of the conservation of mass and momentum equations, includes additional nonlinear terms in the velocity components originated from the shear-dependent viscosity. In absence of axial flow the base flow loses its radial flow stability to the vortex structure at a lower critical Taylor number, as the pseudoplasticity increases. The emergence of the vortices corresponds to the onset of a supercritical bifurcation which is also seen in the flow of a linear fluid. However, unlike the Newtonian case, pseudoplastic Taylor vortices lose their stability as the Taylor number reaches a second critical number corresponding to the onset of a Hopf bifurcation. Existence of an axial flow, manifested by a pressure gradient appears to further advance each critical point on the bifurcation diagram. In addition to the simulation of spiral flow, the proposed formulation allows the axial flow to be independent of the main rotating flow. Complete transient flow field together with viscosity maps are also presented.

  4. Tackling complex turbulent flows with transient RANS

    NARCIS (Netherlands)

    Kenjeres, S.; Hanjalic, K.

    2009-01-01

    This article reviews some recent applications of the transient-Reynoldsaveraged Navier–Stokes (T-RANS) approach in simulating complex turbulent flows dominated by externally imposed body forces, primarily by thermal buoyancy and the Lorentz force. The T-RANS aims at numerical resolving unsteady

  5. Transient gas flow through layered porous media

    International Nuclear Information System (INIS)

    Morrison, F.A. Jr.

    1975-01-01

    Low Reynolds number isothermal flow of an ideal gas through layered porous material was investigated analytically. Relations governing the transient flow in one dimension are obtained. An implicit, iterative, unconditionally stable finite difference scheme is developed for calculation of such flows. A computer code, SIROCCO, employing this technique has been written and implemented on the LLL computer system. A listing of the code is included. This code may be effectively applied to the evaluation of stemming plans for underground nuclear experiments. (U.S.)

  6. Transient burnout under rapid flow reduction condition

    International Nuclear Information System (INIS)

    Iwamura, Takamichi

    1987-01-01

    Burnout characteristics were experimentally studied using uniformly heated tube and annular test sections under rapid flow reduction conditions. Observations indicated that the onset of burnout under a flow reduction transient is caused by the dryout of a liquid film on the heated surface. The decrease in burnout mass velocity at the channel inlet with increasing flow reduction rate is attributed to the fact that the vapor flow rate continues to increase and sustain the liquid film flow after the inlet flow rate reaches the steady-state burnout flow rate. This is because the movement of the boiling boundary cannot keep up with the rapid reduction of inlet flow rate. A burnout model for the local condition could be applied to the burnout phenomena with the flow reduction under pressures of 0.5 ∼ 3.9 MPa and flow reduction rates of 0.6 ∼ 35 %/s. Based on this model, a method to predict the burnout time under a flow reduction condition was presented. The calculated burnout times agreed well with experimental results obtained by some investigators. (author)

  7. Transient compressible flows in porous media

    International Nuclear Information System (INIS)

    Morrison, F.A. Jr.

    1975-09-01

    Transient compressible flow in porous media was investigated analytically. The major portion of the investigation was directed toward improving and understanding of dispersion in these flows and developing rapid accurate numerical techniques for predicting the extent of dispersion. The results are of interest in the containment of underground nuclear experiments. The transient one-dimensional transport of a trace component in a gas flow is analyzed. A conservation equation accounting for the effects of convective transport, dispersive transport, and decay, is developed. This relation, as well as a relation governing the fluid flow, is used to predict trace component concentration as a function of position and time. A detailed analysis of transport associated with the isothermal flow of an ideal gas is done. Because the governing equations are nonlinear, numerical calculations are performed. The ideal gas flow is calculated using a highly stable implicit iterative procedure with an Eulerian mesh. In order to avoid problems of anomolous dispersion associated with finite difference calculation, trace component convection and dispersion are calculated using a Lagrangian mesh. Details of the Eulerian-Lagrangian numerical technique are presented. Computer codes have been developed and implemented on the Lawrence Livermore Laboratory computer system

  8. Electroosmotically controllable multi-flow microreactor

    NARCIS (Netherlands)

    Kohlheyer, D.; Besselink, G.A.J.; Lammertink, Rob G.H.; Schlautmann, Stefan; Unnikrishnan, S.; Schasfoort, Richardus B.M.

    2005-01-01

    An adjustable diffusion-based microfluidic reactor is presented here, which is based on electro-osmotic guiding of reagent samples. The device consists of a laminar flow chamber with two separate reagent inlets. The position and the width of the two sample streams in the flow chamber can be

  9. EVENT, Explosive Transients in Flow Networks

    International Nuclear Information System (INIS)

    Andrae, R.W.; Tang, P.K.; Bolstad, J.W.; Gregory, W.S.

    1985-01-01

    1 - Description of problem or function: A major concern of the chemical, nuclear, and mining industries is the occurrence of an explosion in one part of a facility and subsequent transmission of explosive effects through the ventilation system. An explosive event can cause performance degradation of the ventilation system or even structural failures. A more serious consequence is the release of hazardous materials to the environment if vital protective devices such as air filters, are damaged. EVENT was developed to investigate the effects of explosive transients through fluid-flow networks. Using the principles of fluid mechanics and thermodynamics, governing equations for the conservation of mass, energy, and momentum are formulated. These equations are applied to the complete network subdivided into two general components: nodes and branches. The nodes represent boundaries and internal junctions where the conservation of mass and energy applies. The branches can be ducts, valves, blowers, or filters. Since in EVENT the effect of the explosion, not the characteristics of the explosion itself, is of interest, the transient is simulated in the simplest possible way. A rapid addition of mass and energy to the system at certain locations is used. This representation is adequate for all of the network except the region where the explosion actually occurs. EVENT84 is a modification of EVENT which includes a new explosion chamber model subroutine based on the NOL BLAST program developed at the Naval Ordnance Laboratory, Silver Spring, Maryland. This subroutine calculates the confined explosion near-field parameters and supplies the time functions of energy and mass injection. Solid-phase or TNT-equivalent explosions (which simulate 'point source' explosions in nuclear facilities) as well as explosions in gas-air mixtures can be simulated. The four types of explosions EVENT84 simulates are TNT, hydrogen in air, acetylene in air, and tributyl phosphate (TBP or 'red oil

  10. Analysis of the transient compressible vapor flow in heat pipe

    International Nuclear Information System (INIS)

    Jang, J.H.; Faghri, A.; Chang, W.S.

    1989-07-01

    The transient compressible one-dimensional vapor flow dynamics in a heat pipe is modeled. The numerical results are obtained by using the implicit non-iterative Beam-Warming finite difference method. The model is tested for simulated heat pipe vapor flow and actual vapor flow in cylindrical heat pipes. A good comparison of the present transient results for the simulated heat pipe vapor flow with the previous results of a two-dimensional numerical model is achieved and the steady state results are in agreement with the existing experimental data. The transient behavior of the vapor flow under subsonic, sonic, and supersonic speeds and high mass flow rates are successfully predicted. The one-dimensional model also describes the vapor flow dynamics in cylindrical heat pipes at high temperatures

  11. Molecular Dynamics of Membrane-Spanning DNA Channels: Conductance Mechanism, Electro-Osmotic Transport, and Mechanical Gating.

    Science.gov (United States)

    Yoo, Jejoong; Aksimentiev, Aleksei

    2015-12-03

    DNA self-assembly has emerged as a new paradigm for design of biomimetic membrane channels. Several experimental groups have already demonstrated assembly and insertion of DNA channels into lipid bilayer membranes; however, the structure of the channels and their conductance mechanism have remained undetermined. Here, we report the results of molecular dynamics simulations that characterized the biophysical properties of the DNA membrane channels with atomic precision. We show that, while overall remaining stable, the local structure of the channels undergoes considerable fluctuations, departing from the idealized design. The transmembrane ionic current flows both through the central pore of the channel as well as along the DNA walls and through the gaps in the DNA structure. Surprisingly, we find that the conductance of DNA channels depend on the membrane tension, making them potentially suitable for force-sensing applications. Finally, we show that electro-osmosis governs the transport of druglike molecules through the DNA channels.

  12. Solute dispersion under electric and pressure driven flows; pore scale processes

    NARCIS (Netherlands)

    Li, S.; Raoof, A.; Schotting, R.

    2014-01-01

    Solute dispersion is one of the major mixing mechanisms in transport through porous media, originating from velocity variations at different scales, starting from the pore scale. Different driving forces, such as pressure driven flow (PDF) and electro-osmotic flow (EOF), establish different velocity

  13. AC field effect flow control of EOF in complex microfluidic systems with integrated electrodes

    NARCIS (Netherlands)

    van der Wouden, E.J.; Pennathur, S.; van den Berg, Albert; Locascio, L.E.; Gaitan, M.; Paegel, B.M.; Ross, D.J.; Vreeland, W.N.

    2008-01-01

    In this work, we demonstrate that positive net flow can be induced and controlled with relatively low potential due to the parallel alignment of the integrated channel electrodes. Therefore, we present a novel method to exquisitely control Electro Osmotic Flow (EOF) by using integrated electrodes

  14. Current capabilities of transient two-phase flow instruments

    International Nuclear Information System (INIS)

    Solbrig, C.W.; Kondic, N.N.

    1979-01-01

    The measurement of two phase flow phenomena in transient conditions representative of a Loss-of-Coolant Accident requires the use of sophisticated instruments and the further development of other instruments. Measurements made in large size pipes are often flow regime dependent. The flow regimes encountered depend upon the system geometry, transient effects, heat transfer, etc. The geometries in which these measurements must be made, the instruments which are currently used, new instruments being developed, the facilities used to calibrate these instruments, and the improvements which must be made to measurement capabilities are described

  15. Transient flows of a Burgers' fluid

    International Nuclear Information System (INIS)

    Khan, M.

    2005-12-01

    An analysis is performed to develop the analytical solutions for some unsteady magnetohydrodynamic (MHD) flows of a Burgers' fluid between two plates. A uniform magnetic field is applied transversely to the fluid motion. The exact solutions are given for three problems. Results for the velocity fields are discussed and compared with the flows of Oldroyd-B, Maxwell, second grade and Newtonian fluids. (author)

  16. A new transiently chaotic flow with ellipsoid equilibria

    Science.gov (United States)

    Panahi, Shirin; Aram, Zainab; Jafari, Sajad; Pham, Viet-Thanh; Volos, Christos; Rajagopal, Karthikeyan

    2018-03-01

    In this article, a simple autonomous transiently chaotic flow with cubic nonlinearities is proposed. This system represents some unusual features such as having a surface of equilibria. We shall describe some dynamical properties and behaviours of this system in terms of eigenvalue structures, bifurcation diagrams, time series, and phase portraits. Various behaviours of this system such as periodic and transiently chaotic dynamics can be shown by setting special parameters in proper values. Our system belongs to a newly introduced category of transiently chaotic systems: systems with hidden attractors. Transiently chaotic behaviour of our proposed system has been implemented and tested by the OrCAD-PSpise software. We have found a proper qualitative similarity between circuit and simulation results.

  17. Gulping phenomena in transient countercurrent two-phase flow

    International Nuclear Information System (INIS)

    Tehrani, Ali A.K.

    2001-04-01

    Apart from previous work on countercurrent gas-liquid flow, transient tank drainage through horizontal off-take pipes is described, including experimental procedure, flow pattern on observations and countercurrent flow limitation results. A separate chapter is devoted to countercurrent two-phase flow in a pressurised water reactor hot-leg scaled model. Results concerning low head flooding, high head and loss of bowl flooding, transient draining of the steam generator and pressure variation and bubble detachment are presented. The following subjects are covered as well: draining of sealed tanks of vertical pipes, unsteady draining of closed vessel via vertical tube, unsteady filling of a closed vessel via vertical tube from a constant head reservoir. Practical significance of the results obtained is discussed

  18. Transient heat transfer for forced convection flow of helium gas

    International Nuclear Information System (INIS)

    Liu, Qiusheng; Fukuda, Katsuya; Sasaki, Kenji; Yamamoto, Manabu

    1999-01-01

    Transient heat transfer coefficients for forced convection flow of helium gas over a horizontal cylinder were measured using a forced convection test loop. The platinum heater with a diameter of 1.0 mm was heated by electric current with an exponential increase of Q 0 exp(t/τ). It was clarified that the heat transfer coefficient approaches the steady-state one for the period τ over 1 s, and it becomes higher for the period of τ shorter than 1 s. The transient heat transfer shows less dependent on the gas flowing velocity when the period becomes very shorter. Semi-empirical correlations for steady-state and transient heat transfer were developed based on the experimental data. (author)

  19. A new transiently chaotic flow with ellipsoid equilibria

    Indian Academy of Sciences (India)

    SHIRIN PANAHI

    2018-02-08

    Feb 8, 2018 ... Abstract. In this article, a simple autonomous transiently chaotic flow with cubic nonlinearities is proposed. This system represents some unusual features such as having a surface of equilibria. We shall describe some dynamical properties and behaviours of this system in terms of eigenvalue structures, ...

  20. Transient heat transfer for forced convection flow of helium gas

    International Nuclear Information System (INIS)

    Liu, Qiusheng; Fukuda, Katsuya

    2002-01-01

    The knowledge of forced convection transient heat transfer at various periods of exponential increase of heat input to a heater is important as a database for understanding the transient heat transfer process in a high temperature gas cooled reactor (HTGR) due to an accident in excess reactivity. The transient heat transfer coefficients for forced convection flow of helium gas over a horizontal cylinder were measured using a forced convection test loop. The platinum heater with a diameter of 1.0 mm was heated by electric current with an exponential increase of Q 0 exp(t/τ). It was clarified that the heat transfer coefficient approaches the quasi-steady-state one for the period τ over 1 s, and it becomes higher for the period of τ shorter than 1 s. The transient heat transfer shows less dependent on the gas flowing velocity when the period becomes very shorter. Semi-empirical correlations for quasi-steady-state and transient heat transfer were developed based on the experimental data. (author)

  1. Transient flows occurring during the accelerated crucible rotation technique

    International Nuclear Information System (INIS)

    Horowitz, Atara; Horowitz, Yigal

    1992-11-01

    The transient flows occurring after a change in the angular velocity of the cylindrical container are described. The dependence of the transient (known as spin-up or spin-down time) on experimental parameters as kinematic viscosity, cylinder dimensions and the cylinder's initial and final angular velocities are elucidates by a review of the literature. It is emphasized that with large Rossby numbers the spin-up time is longer and the amount of fluid mixing is greater than small and moderate Rossby numbers. It is also elucidated that most crystal growth crucibles cannot be considered as infinitely-long cylinders for the evaluation of the fluid dynamics (authors)

  2. Coupled equations for transient water flow, heat flow, and ...

    Indian Academy of Sciences (India)

    Hydrogeological systems are earth systems influenced by water. Their behaviors are governed by interacting processes, including flow of fluids, deformation of porous materials, chemical reactions, and transport of matter and energy. Here, coupling among three of these processes is considered: flow of water, heat, and ...

  3. Applying well flow adapted filtering to transient pumping tests

    Science.gov (United States)

    Zech, Alraune; Attinger, Sabine

    2014-05-01

    Transient pumping tests are often used to estimate porous medium characteristics like hydraulic conductivity and storativity. The interpretation of pumping test drawdowns is based on methods which are normally developed under the assumption of homogeneous porous media. However aquifer heterogeneity strongly impacts on well flow pattern, in particular in the vicinity of the pumping well. The purpose of this work is to present a method to interpret drawdowns of transient pumping tests in heterogeneous porous media. With this method we are able to describe the effects that statistical quantities like variance and correlation length have on pumping test drawdowns. Furthermore it allows inferring on the statistical parameters of aquifer heterogeneity from drawdown data by invers estimation, which is not possible using methods for homogeneous media like Theis' solution. The method is based on a representative description of hydraulic conductivity for radial flow regimes. It is derived from a well flow adapted filtering procedure (Coarse Graining), where the heterogeneity of hydraulic conductivity is assumed to be log-normal distributed with a Gaussian correlation structure. applying the up scaled hydraulic conductivity to the groundwater flow equation results in a hydraulic head which depends on the statistical parameters of the porous medium. It describes the drawdown of a transient pumping test in heterogeneous media. We used an ensemble of transient pumping test simulations to verify the up scaled drawdown solution. We generated transient pumping tests in heterogeneous media for various values of the statistical parameters variance and correlation length and evaluated their impact on the drawdown behavior as well as on the temporal evolution. We further examined the impact of several aspects like the location of an observation well or the local conductivity at the pumping well on the drawdown behavior. This work can be understood as an expansion of the work of Zech et

  4. Analysis of forced convective transient boiling by homogeneous model of two-phase flow

    International Nuclear Information System (INIS)

    Kataoka, Isao

    1985-01-01

    Transient forced convective boiling is of practical importance in relation to the accident analysis of nuclear reactor etc. For large length-to-diameter ratio, the transient boiling characteristics are predicted by transient two-phase flow calculations. Based on homogeneous model of two-phase flow, the transient forced convective boiling for power and flow transients are analysed. Analytical expressions of various parameters of transient two-phase flow have been obtained for several simple cases of power and flow transients. Based on these results, heat flux, velocity and time at transient CHF condition are predicted analytically for step and exponential power increases, and step, exponential and linear velocity decreases. The effects of various parameters on heat flux, velocity and time at transient CHF condition have been clarified. Numerical approach combined with analytical method is proposed for more complicated cases. Solution method for pressure transient are also described. (author)

  5. Transient performance of flow in PWR reactor circuits

    International Nuclear Information System (INIS)

    Hirdes, V.R.T.R.; Carajilescov, P.

    1988-12-01

    Generally, PWR's are designed with several primary loops, each one provided with a pump to circulate the coolant through the core. If one or more of these pumps fail, there would be a decrease in reactor flow rate which cause coolant phase change in the core and components overheating. The present work establishes a simulation model for pump failure in PWR's and the SARDAN-FLOW computes code was developed, considering any combination of such failures. Based on the data of Angra I, several accident and operational transient conditions were simulated. (author) [pt

  6. Transient performance of flow in circuits of PWR type reactors

    International Nuclear Information System (INIS)

    Hirdes, V.R.; Carajilescov, P.

    1988-09-01

    Generally, PWR's are designed with several primary loops, each one provided with a pump to circulate the coolant through the core. If one or more of these pumps fail, there would be a decrease in reactor flow rate which could cause coolant phase change in the core and components overheating. The present work establishes a simulation model for pump failure in PWR's and the SARDAN-FLOW computes code was developed, considering any combination of such failures. Based on the data of Angra I, several accident and operational transient conditions were simulated. (author) [pt

  7. Transient Characteristics of a Fluidic Device for Circulatory Jet Flow

    Directory of Open Access Journals (Sweden)

    Hoa Thanh Phan

    2018-03-01

    Full Text Available In this paper, we report on the design, simulation, and experimental analysis of a miniaturized device that can generate multiple circulated jet flows. The device is actuated by a lead zirconate titanate (PZT diaphragm. The flows in the device were studied using three-dimensional transient numerical simulation with the programmable open source OpenFOAM and was comparable to the experimental result. Each flow is verified by two hotwires mounted at two positions inside each consisting chamber. The experiment confirmed that the flow was successfully created, and it demonstrated good agreement with the simulation. In addition, a prospective application of the device as an angular rate sensor is also demonstrated. The device is robust, is minimal in size, and can contribute to the development of multi-axis fluidic inertial sensors, fluidic amplifiers, gas mixing, coupling, and analysis.

  8. Transient flow characteristics of a high speed rotary valve

    Science.gov (United States)

    Browning, Patrick H.

    Pressing economic and environmental concerns related to the performance of fossil fuel burning internal combustion engines have revitalized research in more efficient, cleaner burning combustion methods such as homogeneous charge compression ignition (HCCI). Although many variations of such engines now exist, several limiting factors have restrained the full potential of HCCI. A new method patented by West Virginia University (WVU) called Compression Ignition by Air Injection (CIBAI) may help broaden the range of effective HCCI operation. The CIBAI process is ideally facilitated by operating two synchronized piston-cylinders mounted head-to-head with one of the cylinders filled with a homogeneous mixture of air and fuel and the other cylinder filled with air. A specialized valve called the cylinder connecting valve (CCV) separates the two cylinders, opens just before reaching top dead center (TDC), and allows the injection air into the charge to achieve autoignition. The CCV remains open during the entire power stroke such that upon ignition the rapid pressure rise in the charge cylinder forces mass flow back through the CCV into the air-only cylinder. The limited mass transfer between the cylinders through the CCV limits the theoretical auto ignition timing capabilities and thermal efficiency of the CIBAI cycle. Research has been performed to: (1) Experimentally measure the transient behavior of a potential CCV design during valve opening between two chambers maintained at constant pressure and again at constant volume; (2) Develop a modified theoretical CCV mass flow model based upon the measured cold flow valve performance that is capable of predicting the operating conditions required for successful mixture autoignition; (3) Make recommendations for future CCV designs to maximize CIBAI combustion range. Results indicate that the modified-ball CCV design offers suitable transient flow qualities required for application to the CIBAI concept. Mass injection events

  9. Experimental investigations on transient single phase flow through perforated plates

    International Nuclear Information System (INIS)

    Casadei, F.

    1983-01-01

    The transient flow of the coolant through the perforated dip-plate during a HCDA in a LMFBR was simulated in a one-dimensional experimental model. Several experiments with water as fluid and with various perforation ratios of the dip-plate and different initial heights of the fluid head over the dip-plate were run. The pressure drop across the dip-plate and the forces acting on the dip-plate and on the upper plug of the reactor vessel were measured in a wide range of the Reynolds and Strouhal numbers. The flow pattern downstreams the perforated plate was filmed with high-speed cameras. The resistance coefficients for the transient flow of the coolant through the perforated plate were obtained as a function of the acceleration. The forces acting on the upper plug and their time integral were compared with those acting on the dip-plate. Finally, using high-speed film pictures the formation of fluid jets downstream the dip-plate was investigated. (orig.)

  10. Transient radial flow to a well in an unconfined aquifer

    Energy Technology Data Exchange (ETDEWEB)

    Narasimhan, T.N.; Zhu, Ming.

    1991-08-01

    The analytic solutions of Boulton (1954) and Neuman (1972) for transient flow to a well in an unconfined aquifer are based on the assumption that the role of the unsaturated zone can be adequately accounted for by restricting attention to the release of water from the zone through which the water table moves. Both researchers mathematically treat this released water as a time-dependent source term. The differences between the models of Boulton and Neuman are that the former neglects vertical components of flow in the aquifer, but allows for an exponential process for the release of water as a function of time, whereas the latter assumes instantaneous release from storage, but accounts for vertical components of flow. Given this set of assumptions, we examine the applicability of these two methods using a general purpose numerical model through a process of verification extension and comparison. The issues addressed include: the role of well-bore storage in masking intermediate-time behavior, combined effects of exponential release as well as vertical flow, logic for vertical averaging of drawdowns, and the sensitivity of system response to the magnitude of specific yield. The issue of how good the assumptions of Boulton and Neuman are in the context of the general theory of unsaturated flow is addressed in part 2 of this two-part series of reports.

  11. 4. Workshop - Measurement techniques of stationary and transient multiphase flow

    Energy Technology Data Exchange (ETDEWEB)

    Prasser, H.M. (ed.)

    2001-05-01

    In November 2000, the 4th Workshop on Measurement Techniques for Stationary and Transient Multiphase Flows took place in Rossendorf. Three previous workshops of this series were national meetings; this time participants from different countries took part. The programme comprised 14 oral presentations, 9 of which are included in these proceedings in full length. A special highlight of the meeting was the main lecture ''Ultrasonic doppler method for bubbly flow measurement'' of Professor Masanori Aritomi, Dr. Hiroshige Kikura and Dr. Yumiko Suzuki. The workshop again dealt with high-resolution phase distribution and phase velocity measurement techniques based on electrical conductivity, ultrasound, laser light and high-speed cinematography. A number of presentations were dedicated to the application of wire-mesh sensors developed by FZR for different applications used by the Technical Universities of Delft and Munich and the Tokyo Institute of Technology. (orig.)

  12. 4. Workshop - Measurement techniques of stationary and transient multiphase flow

    International Nuclear Information System (INIS)

    Prasser, H.M.

    2001-05-01

    In November 2000, the 4th Workshop on Measurement Techniques for Stationary and Transient Multiphase Flows took place in Rossendorf. Three previous workshops of this series were national meetings; this time participants from different countries took part. The programme comprised 14 oral presentations, 9 of which are included in these proceedings in full length. A special highlight of the meeting was the main lecture ''Ultrasonic doppler method for bubbly flow measurement'' of Professor Masanori Aritomi, Dr. Hiroshige Kikura and Dr. Yumiko Suzuki. The workshop again dealt with high-resolution phase distribution and phase velocity measurement techniques based on electrical conductivity, ultrasound, laser light and high-speed cinematography. A number of presentations were dedicated to the application of wire-mesh sensors developed by FZR for different applications used by the Technical Universities of Delft and Munich and the Tokyo Institute of Technology. (orig.)

  13. Improved Flow Modeling in Transient Reactor Safety Analysis Computer Codes

    International Nuclear Information System (INIS)

    Holowach, M.J.; Hochreiter, L.E.; Cheung, F.B.

    2002-01-01

    A method of accounting for fluid-to-fluid shear in between calculational cells over a wide range of flow conditions envisioned in reactor safety studies has been developed such that it may be easily implemented into a computer code such as COBRA-TF for more detailed subchannel analysis. At a given nodal height in the calculational model, equivalent hydraulic diameters are determined for each specific calculational cell using either laminar or turbulent velocity profiles. The velocity profile may be determined from a separate CFD (Computational Fluid Dynamics) analysis, experimental data, or existing semi-empirical relationships. The equivalent hydraulic diameter is then applied to the wall drag force calculation so as to determine the appropriate equivalent fluid-to-fluid shear caused by the wall for each cell based on the input velocity profile. This means of assigning the shear to a specific cell is independent of the actual wetted perimeter and flow area for the calculational cell. The use of this equivalent hydraulic diameter for each cell within a calculational subchannel results in a representative velocity profile which can further increase the accuracy and detail of heat transfer and fluid flow modeling within the subchannel when utilizing a thermal hydraulics systems analysis computer code such as COBRA-TF. Utilizing COBRA-TF with the flow modeling enhancement results in increased accuracy for a coarse-mesh model without the significantly greater computational and time requirements of a full-scale 3D (three-dimensional) transient CFD calculation. (authors)

  14. Exact and Approximate Solutions for Transient Squeezing Flow

    Science.gov (United States)

    Lang, Ji; Santhanam, Sridhar; Wu, Qianhong

    2017-11-01

    In this paper, we report two novel theoretical approaches to examine a fast-developing flow in a thin fluid gap, which is widely observed in industrial applications and biological systems. The problem is featured by a very small Reynolds number and Strouhal number, making the fluid convective acceleration is negligible, while its local acceleration is not. We have developed an exact solution for this problem which shows that the flow starts with an inviscid limit when the viscous effect has no time to appear, and is followed by a subsequent developing flow, in which the viscous effect continues to penetrate into the entire fluid gap. An approximate solution is also developed using a boundary layer integral method. This solution precisely captures the general behavior of the transient fluid flow process, and agrees very well with the exact solution. We also performed numerical simulation using Ansys-CFX. Excellent agreement between the analytical and the numerical solutions is obtained, indicating the validity of the analytical approaches. The study presented herein fills the gap in the literature, and will have a broad impact in industrial and biomedical applications. This work is supported by National Science Foundation CBET Fluid Dynamics Program under Award #1511096, and supported by the Seed Grant from The Villanova Center for the Advancement of Sustainability in Engineering (VCASE).

  15. Variable thickness transient groundwater flow model theory and numerical implementation

    International Nuclear Information System (INIS)

    Kipp, K.L.; Reisenauer, A.E.; Cole, C.R.; Bryan, C.A.

    1976-01-01

    Modeling of radionuclide movement in the groundwater system beneath the Hanford Reservation requires mathematical simulation of the two-dimensional flow in the unconfined aquifer. This was accomplished using the nonlinear, transient Boussinesq equation with appropriate initial and boundary conditions, including measured Columbia River stages and rates of wastewater disposal to the ground. The heterogeneous permeability (hydraulic conductivity) distribution was derived by solution of the Boussinesq equation along instantaneous streamtubes of flow employing a measured water table surface and a limited number of field-measured hydraulic conductivity values. Use of a successive line over-relaxation technique with unequal time steps resulted in a more rapid convergence of the numerical solution than with previous techniques. The model was used to simulate the water table changes for the period 1968 through 1973 using known inputs and boundary conditions. A comparison of calculated and measured water table elevations was made at specific well locations and the quality of the verification simulation was evaluated using a data retrieval and display system. Agreement between the model results and measured data was good over two-thirds of the Hanford Reservation. The capability of the model to simulate flow with time-varying boundary conditions, complex boundary shapes, and a heterogeneous distribution of aquifer properties was demonstrated

  16. Instrumentation to Monitor Transient Developing Periodic Flow in Newtonian Slurries

    Energy Technology Data Exchange (ETDEWEB)

    Bamberger, Judith A.; Enderlin, Carl W.

    2014-08-03

    This paper describes measurement techniques developed and applied to characterize solids mobilization and mixing of Newtonian slurries that are subjected to transient, periodic, developing flows. Metrics to characterize mobilization and mixing are the just suspended velocity (UJS) and the cloud height (HC). Two ultrasonic instruments to characterize pulse jet mixing of slurries were developed and deployed to measure related metrics: the thickness of the settled bed (used to determine mobilization) and the concentration within the cloud as a function of elevation [C(Z)]. A second method, continuous sample extraction, characterization, and reinsertion was successfully used to measure average density and characterize the concentration within the cloud. Testing focused on mixing vessels using intermitent jet mixers oriented vertically downward. Descriptions of the instruments and instrument performance are presented. These techniques were an effective approach to characterize mixing phenomena, determine mixing energy required to fully mobilize vessel contents, and to determine mixing times for process evaluation.

  17. Electron beam induced heat flow transient in aluminium

    International Nuclear Information System (INIS)

    Dalle Rose, L.F.D.; Brotto, R.

    1983-01-01

    On the basis of a numerically solved heat diffusion equation, the structure of the thermal transient induced in an aluminium sample by an electron beam pulse is described in terms of slush zone formation, molten depth, liquid phase duration, and melt front history. The heat flow dynamics, as determined by monochromatic (electron energy ranging between 5 and 25 keV) and ultrashort (15 ns fwhm) pulses, is contrasted with the ruby laser induced one. Accessible absorbed energy intervals for sample surface melting are given as a function of electron energy; heating of the sample interior at values higher than those attained at the surface is shown to occur only at higher electron energies, for a given pulse duration. The general dependence of the present results on the pulse duration and the effects produced by polychromatic pulses are also discussed. (author)

  18. Modeling of Transient Nectar Flow in Hummingbird Tongues

    Science.gov (United States)

    Rico-Guevara, Alejandro; Fan, Tai-Hsi; Rubega, Margaret

    2015-11-01

    We demonstrate that hummingbirds do not pick up floral nectar via capillary action. The long believed capillary rise models were mistaken and unable to predict the dynamic nectar intake process. Instead, hummingbird's tongue acts as an elastic micropump. Nectar is drawn into the tongue grooves during elastic expansion after the grooves are squeezed flat by the beak. The new model is compared with experimental data from high-speed videos of 18 species and tens of individuals of wild hummingbirds. Self-similarity and transitions of short-to-long time behaviours have been resolved for the nectar flow driven by expansive filling. The transient dynamics is characterized by the relative contributions of negative excess pressure and the apparent area modulus of the tongue grooves.

  19. Investigation of the effects of time periodic pressure and engpotential gradients on viscoelastic fluid flow in circular narrow confinements

    DEFF Research Database (Denmark)

    Nguyen, Trieu; van der Meer, Devaraj; van den Berg, Albert

    2017-01-01

    -Boltzmann equation, together with the incompressible Cauchy momentum equation under no-slip boundary conditions for viscoelastic fluid in the case of a combination of time periodic pressure-driven and electro-osmotic flow. The resulting solutions allow us to predict the electrical current and solution flow rate...... conversion applications. We also found that time periodic electro-osmotic flow in many cases is much stronger enhanced than time periodic pressure-driven flow when comparing the flow profiles of oscillating PDF and EOF in micro-and nanochannels. The findings advance our understanding of time periodic......In this paper we present an in-depth analysis and analytical solution for time periodic hydrodynamic flow (driven by a time-dependent pressure gradient and electric field) of viscoelastic fluid through cylindrical micro-and nanochannels. Particularly, we solve the linearized Poisson...

  20. Network Flow Simulation of Fluid Transients in Rocket Propulsion Systems

    Science.gov (United States)

    Bandyopadhyay, Alak; Hamill, Brian; Ramachandran, Narayanan; Majumdar, Alok

    2011-01-01

    Fluid transients, also known as water hammer, can have a significant impact on the design and operation of both spacecraft and launch vehicle propulsion systems. These transients often occur at system activation and shutdown. The pressure rise due to sudden opening and closing of valves of propulsion feed lines can cause serious damage during activation and shutdown of propulsion systems. During activation (valve opening) and shutdown (valve closing), pressure surges must be predicted accurately to ensure structural integrity of the propulsion system fluid network. In the current work, a network flow simulation software (Generalized Fluid System Simulation Program) based on Finite Volume Method has been used to predict the pressure surges in the feed line due to both valve closing and valve opening using two separate geometrical configurations. The valve opening pressure surge results are compared with experimental data available in the literature and the numerical results compared very well within reasonable accuracy (< 5%) for a wide range of inlet-to-initial pressure ratios. A Fast Fourier Transform is preformed on the pressure oscillations to predict the various modal frequencies of the pressure wave. The shutdown problem, i.e. valve closing problem, the simulation results are compared with the results of Method of Characteristics. Most rocket engines experience a longitudinal acceleration, known as "pogo" during the later stage of engine burn. In the shutdown example problem, an accumulator has been used in the feed system to demonstrate the "pogo" mitigation effects in the feed system of propellant. The simulation results using GFSSP compared very well with the results of Method of Characteristics.

  1. Transient solute transport with sorption in Poiseuille flow

    Science.gov (United States)

    Hesse, M. A.; Zhang, L.; Wang, M.

    2016-12-01

    Sorption onto the wall has been observed to both increase [Lungu and Moffatt, 1982] and decrease the average solute transport velocity [Golay, 1958], relative to the mean flow velocity. Similarly, opposite conclusion have been reached for the effect of sorption on dispersion. In this work, we study transient solute transport in Poiseuille flow with sorptive boundary and initial transversely uniform distribution (linear release) to reconcile the two different views on solute transport (figure 1) with sorption. Two-dimensional simulations in figure 2 show that there is a transition from fast transport dominated by a fast-moving pulse in the middle of the channel at early times, to slow transport at late times once desorption from the walls becomes important. A set of series solutions for zeroth, first and second longitudinal moment have been derived and we show that the zeroth-order term in the solution corresponds to the slow transport in the late regime, while the first-order term corresponds to the fast transport in the early regime (figure 3). Based on the analytical solution, the time scales for early regime and late regimes of both the velocity and the dispersion coefficient have been determined for an equilibrium sorption model and a kinetic linear sorption model. Furthermore, we give approximated analytical solution when both adsorption and desorption are slow. References M.J.E. Golay. Theory of chromatography in open and coated tubular columns iwth round and rectangular cross-sections. In D.H.Desty, editor, Gas Chromatography, pages 36-53, New York, 1958. Academic Press Inc. E.M. Lungu and H.K. Moffatt. the effect of wall conductance on heat diffusion in duct flow. Journal of Engineering Mathematics, 1692 ;121-136, 1982.

  2. Availability of electro-osmotic process for treating contaminated clays with gasoline; Viabiliadade do processo eletro-osmotico para remediacao de solo argiloso contaminado com gasolina

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Veronica E.; Neri, Katya D. [Universidade Estadual da Paraiba (UEPB), Joao Pessoa, PB (Brazil); Vilar, Eudesio O. [Universidade Federal de Campina Grande (UFCG), PB (Brazil)

    2008-07-01

    The electrochemical mobilization of organic compounds occurs through simultaneously drag with the interstitial fluid (electrosmosis). For this study of electroremediation it was used a rectangular reactor filled with 1700 g of clay mixture (47% fine sand, 48% bentonite and 5% vermiculite) previously contaminated with gasoline. DSA - electrodes were inserted directly into the soil. The results of efficiency of mobilization to several initial soil moisture content (20-50%), time of experiment (48 - 72 h) and intensity of electric field (1-3 V/Cm) were confronted with the changes of pH, resulting from electrosmosis process. It was observed that the mobilization of the contaminant increased by increasing the time and intensity of electric field, in lower initial moisture. The tests results show that the best conditions for processing are 72 hours, 20% humidity and 3V/cm. In those circumstances it was possible to mobilize 46% of the initial concentration of gasoline, percentage found near the anode. The electrolysis provided soil acidification. It was found soil pH values above 11 near the cathode and below 2 neighbour to the anode, a factor that contributed to produce an electrosmosis reverse flow (cathode-anode flow direction). It is concluded that the mobilization by electrochemistry phenomena of gasoline in clay soil is possible, its efficiency, however depends on the proper control of the conditions of the process including pH (author)

  3. Transient hydraulics and heat transfer in a turbulent flow

    International Nuclear Information System (INIS)

    Kawamura, H.

    1975-06-01

    In a reactor transient analysis, the friction factor and the heat transfer coefficient are assumed equal to the steady state values even in a transient state. This quasi-static assumption has been examined in the present paper. (orig./TK) [de

  4. Nanoscale transient porosity controls large-scale metamorphic fluid flow

    Science.gov (United States)

    Plümper, Oliver; Botan, Alexandru; Los, Catharina; Malthe-Sørenssen, Anders; Jamtveit, Bjørn

    2016-04-01

    The reaction of fluids with rocks is fundamental for Earth's dynamics as they facilitate heat/mass transfer and induce volume changes, weaknesses and instabilities in rock masses that localize deformation enabling tectonic responses to plate motion. During these fluid-rock interactions it is the ability of a rock to transmit fluid, its permeability, that controls the rates of metamorphic reactions. However, although some geological environments (e.g., sediments) are open to fluids, the majority of solid rocks (e.g., granites, elcogites, peridotites, etc.) are nearly impermeable. Surprisingly though, even in rocks that are nominally impermeable widespread fluid-rock interactions are observed leading to the question: How can fluids migrate through vast amounts of nominally impermeable rocks? Here we investigate one of the most wide-spread fluid-mediated metamorphic processes in the Earth's crust, the albitization of feldspatic rocks. We show that fluid flow and element mobilization during albitization is controlled by an interaction between grain boundary diffusion and reaction front migration through an interface-coupled dissolution-precipitation process. Using a combination of focused ion beam scanning electron microscopy (FIB-SEM)-assisted nanotomography combined with transmission electron microscopy (TEM) reveals that the porosity is dictated by pore channels with a pore diameter ranging between 10 to 100 nm. Three-dimensional visualization of the feldspar pore network reveals that the pore channels must have been connected during the replacement reaction. Analysis of the pore aspect ratios suggests that a Rayleigh-Taylor-type instability associated to surface energy minimization caused the disconnection of the pore channels. Fluid transport in nanometer-sized objects with at least one characteristic dimension below 100 nm enables the occurrence of physical phenomena that are impossible at bigger length scales. Thus, on the basis of our microstructural

  5. A flux monitoring method for easy and accurate flow rate measurement in pressure-driven flows.

    Science.gov (United States)

    Siria, Alessandro; Biance, Anne-Laure; Ybert, Christophe; Bocquet, Lydéric

    2012-03-07

    We propose a low-cost and versatile method to measure flow rate in microfluidic channels under pressure-driven flows, thereby providing a simple characterization of the hydrodynamic permeability of the system. The technique is inspired by the current monitoring method usually employed to characterize electro-osmotic flows, and makes use of the measurement of the time-dependent electric resistance inside the channel associated with a moving salt front. We have successfully tested the method in a micrometer-size channel, as well as in a complex microfluidic channel with a varying cross-section, demonstrating its ability in detecting internal shape variations.

  6. Characteristic behavior of bubbles and slugs in transient two-phase flow using image-processing method

    International Nuclear Information System (INIS)

    Goto, Shoji; Ishizaki, Yasuo; Ohashi, Hirotada; Akiyama, Mamoru

    1995-01-01

    Simulation of transient two-phase flow has been performed by solving transient hydrodynamic equations. However, constitution relations used in this simulation are primarily based on steady-state experimental results. Thus it is important to understand the transient behavior of bubbles and slugs, in particular, transient behavior of the void fraction, the interfacial area and the flow pattern, to confirm the applicability of the present simulation method and to advance two-phase flow simulation further. The present study deals with measurement of transient two-phase flow. We have measured local and instantaneous void fractions using imaging techniques, and compared the experimental data with simulation results. (author)

  7. Study on numerical methods for transient flow induced by speed-changing impeller of fluid machinery

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Dazhuan; Chen, Tao; Wang, Leqin [Zhejiang University, Hangzhou (China); Cheng, Wentao [Research Institute of Product Quality and Standard of Ministry of Water Recourse, Hangzhou (China); Sun, Youbo [Zhejiang Academy of Safety Science and Technology, Hangzhou (China)

    2013-06-15

    In order to establish a reliable numerical method for solving the transient rotating flow induced by a speed-changing impeller, two numerical methods based on finite volume method (FVM) were presented and analyzed in this study. Two-dimensional numerical simulations of incompressible transient unsteady flow induced by an impeller during starting process were carried out respectively by using DM and DSR methods. The accuracy and adaptability of the two methods were evaluated by comprehensively comparing the calculation results. Moreover, an intensive study on the application of DSR method was conducted subsequently. The results showed that transient flow structure evolution and transient characteristics of the starting impeller are obviously affected by the starting process. The transient flow can be captured by both two methods, and the DSR method shows a higher computational efficiency. As an application example, the starting process of a mixed-flow pump was simulated by using DSR method. The calculation results were analyzed by comparing with the experiment data.

  8. Study on numerical methods for transient flow induced by speed-changing impeller of fluid machinery

    International Nuclear Information System (INIS)

    Wu, Dazhuan; Chen, Tao; Wang, Leqin; Cheng, Wentao; Sun, Youbo

    2013-01-01

    In order to establish a reliable numerical method for solving the transient rotating flow induced by a speed-changing impeller, two numerical methods based on finite volume method (FVM) were presented and analyzed in this study. Two-dimensional numerical simulations of incompressible transient unsteady flow induced by an impeller during starting process were carried out respectively by using DM and DSR methods. The accuracy and adaptability of the two methods were evaluated by comprehensively comparing the calculation results. Moreover, an intensive study on the application of DSR method was conducted subsequently. The results showed that transient flow structure evolution and transient characteristics of the starting impeller are obviously affected by the starting process. The transient flow can be captured by both two methods, and the DSR method shows a higher computational efficiency. As an application example, the starting process of a mixed-flow pump was simulated by using DSR method. The calculation results were analyzed by comparing with the experiment data.

  9. Columbia University flow instability experimental program: Volume 6. Single annulus tests, transient test program

    Energy Technology Data Exchange (ETDEWEB)

    Dougherty, T.; Maciuca, C.; McAssey, E.V. Jr.; Reddy, D.G.; Yang, B.W.

    1992-09-01

    The coolant in the Savannah River Site (SRS) production nuclear reactor assemblies is circulated as a subcooled liquid under normal operating conditions. This coolant is evenly distributed throughout multiple annular flow channels with a uniform pressure profile across each coolant flow channel. During the postulated Loss of Coolant Accident (LOCA), which is initiated by a hypothetical guillotine pipe break, the coolant flow through the reactor assemblies is significantly reduced. The flow reduction and accompanying power reduction (after shutdown is initiated) occur in the first 1 to 2 seconds of the LOCA. This portion of the LOCA is referred to as the Flow Instability phase. This report presents the experimental results for the transient portion of the single annulus test program. The test program was designed to investigate the onset of flow instability in an annular geometry similar to the MARK 22 reactor. The test program involved testing of both a ribless heater and a ribbed heater under steady state as well as transient conditions. The ribbed heater testing is currently underway and will be reported separately. The steady state portion of this test program with ribless heater was completed and reported in report No. CU-HTRF-T3A. The present report presents transient test results obtained from a ribless, uniform annulus test section. A total of thirty five transients were conducted with six cases in which flow excursion occurred. No unstable conditions resulted for tests in which the steady state Q{sub ratio} OFI limit was not exceeded.

  10. Investigation of Transient Flow in a Centrifugal Charging Pump during Charging Operating Process

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    2014-06-01

    Full Text Available Centrifugal charging pumps are important components of nuclear power plants and must be operated under multioperating conditions for the requirements of the system. In order to investigate the internal flow mechanism of the centrifugal charging pump during the transient transition process of charging operating from Q = 34 m3/h to Q = 110 m3/h, numerical simulation and experiment are implemented in this study. The relationship between flow rate and time is obtained from the experiment and worked as the boundary condition to accurately accomplish the numerical simulation during the transient process. External and internal characteristics under the variable operating conditions are analyzed through the transient simulation. The results show that the liquid viscosity, large scale vortexes exist in the flow passages in the beginning of the variable operating conditions, which indicates flow separation and the sudden changes in direction of velocity. As the flow rate increases gradually, the flow angles of the fluid in inlet accelerate correspondingly and the flow along the blade is more uniform, which leads to a decrease and movements of the vortexes. The contents of the current work can provide references for the design optimization and fluid control of the pump used in the transient process of variable operating conditions.

  11. And yet it moves! Involving transient flow conditions is the logical next step for WHPA analysis

    Science.gov (United States)

    Rodriguez-Pretelin, A.; Nowak, W.

    2017-12-01

    As the first line of defense among different safety measures, Wellhead Protection Areas (WHPAs) have been broadly used to protect drinking water wells against sources of pollution. In most cases, their implementation relies on simplifications, such as assuming homogeneous or zonated aquifer conditions or considering steady-state flow scenarios. Obviously, both assumptions inevitably invoke errors. However, while uncertainty due to aquifer heterogeneity has been extensively studied in the literature, the impact of transient flow conditions have received yet very little attention. For instance, WHPA maps in the offices of water supply companies are fixed maps derived from steady-state models although the actual catchment out there are transient. To mitigate high computational costs, we approximate transiency by means of a dynamic superposition of steady-state flow solutions. Then, we analyze four transient drivers that often appear on the seasonal scale: (I) regional groundwater flow direction, (II) strength of the regional hydraulic gradient, (III) natural recharge to the groundwater and (IV) pumping rate. The integration of transiency in WHPA analysis leads to time-frequency maps. They express for each location the temporal frequency of catchment membership. Furthermore, we account for the uncertainty due to incomplete knowledge on geological and transiency conditions, solved through Monte Carlo simulations. The main contribution of this study, is to show the need of enhancing groundwater well protection by considering transient flow considerations during WHPA analysis. To support and complement our statement, we demonstrate that 1) each transient driver imprints an individual spatial pattern in the required WHPA, ranking their influence through a global sensitivity analysis. 2) We compare the influence of transient conditions compared to geological uncertainty in terms of areal WHPA demand. 3) We show that considering geological uncertainty alone is insufficient

  12. Implicit analysis of the transient water flow with dissolved air

    Directory of Open Access Journals (Sweden)

    J. Twyman

    2018-01-01

    Full Text Available The implicit finite-difference method (IFDM for solving a system that transports water with dissolved air using a fixed (or variable rectangular space-time mesh defined by the specified time step method is applied. The air content in the fluid modifies both the wave speed and the Courant number, which makes it inconvenient to apply the traditional Method of Characteristics (MOC and other explicit schemes due to their impossibility to simulate the changes in magnitude, shape and frequency of the pressures train. The conclusion is that the IFDM delivers an accurate and stable solution, with a good adjustment level with respect to a classical case reported in the literature, being a valid alternative for the transient solution in systems that transport water with dissolved air.

  13. Investigation of transient cavitating flow in viscoelastic pipes

    International Nuclear Information System (INIS)

    Keramat, A; Tijsseling, A S; Ahmadi, A

    2010-01-01

    A study on water hammer in viscoelastic pipes when the fluid pressure drops to liquid vapour pressure is performed. Two important concepts including column separation and the effects of retarded strains in the pipe wall on the fluid response have been investigated separately in recent works, but there is some curiosity as to how the results for pressure and discharge are when column separation occurs in a viscoelastic pipe. For pipes made of plastic such as polyethylene (PE) and polyvinyl chloride (PVC), viscoelasticity is a crucial mechanical property which changes the hydraulic and structural transient responses. Based on previous developments in the analysis of water hammer, a model which is capable of analysing column separation in viscoelastic pipes is presented and used for solving the selected case studies. For the column-separation modelling the Discrete Vapour Cavity Model (DVCM) is utilised and the viscoelasticity property of the pipe wall is modelled by Kelvin-Voigt elements. The effects of viscoelasticity play an important role in the column separation phenomenon because it changes the water hammer fundamental frequency and so affects the time of opening or collapse of the cavities. Verification of the implemented computer code is performed for the effects of viscoelasticity and column separation - separately and simultaneously - using experimental results from the literature. In the provided examples the focus is placed on the simultaneous effect of viscoelasticity and column separation on the hydraulic transient response. The final conclusions drawn are that if rectangular grids are utilised the DVCM gives acceptable predictions of the phenomenon and that the pipe wall material's retarded behaviour strongly dampens the pressure spikes caused by column separation.

  14. Transient critical heat flux under flow coast-down in vertical annulus with non-uniform heat flux distribution

    International Nuclear Information System (INIS)

    Moon, S.K.; Chun, S.Y.; Choi, K.Y.; Yang, S.K.

    2001-01-01

    An experimental study on transient critical heat flux (CHF) under flow coast-down has been performed for water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady state CHF. The transient CHF experiments have been performed for three kinds of flow transient modes based on the coast-down data of the Kori 3/4 nuclear power plant reactor coolant pump. Most of the CHFs occurred in the annular-mist flow regime. Thus, it means that the possible CHF mechanism might be the liquid film dryout in the annular-mist flow regime. For flow transient mode with the smallest flow reduction rate, the time-to-CHF is the largest. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to-CHF becomes large as the heat flux decreases. Usually, the critical mass flux is large for slow flow reduction. There is a pressure effect on the ratio of the transient CHF data to steady state CHF data. Some conventional correlations show relatively better CHF prediction results for high system pressure, high quality and slow transient modes than for low system pressure, low quality and fast transient modes. (author)

  15. Performance assessment of mass flow rate measurement capability in a large scale transient two-phase flow test system

    International Nuclear Information System (INIS)

    Nalezny, C.L.; Chapman, R.L.; Martinell, J.S.; Riordon, R.P.; Solbrig, C.W.

    1979-01-01

    Mass flow is an important measured variable in the Loss-of-Fluid Test (LOFT) Program. Large uncertainties in mass flow measurements in the LOFT piping during LOFT coolant experiments requires instrument testing in a transient two-phase flow loop that simulates the geometry of the LOFT piping. To satisfy this need, a transient two-phase flow loop has been designed and built. The load cell weighing system, which provides reference mass flow measurements, has been analyzed to assess its capability to provide the measurements. The analysis consisted of first performing a thermal-hydraulic analysis using RELAP4 to compute mass inventory and pressure fluctuations in the system and mass flow rate at the instrument location. RELAP4 output was used as input to a structural analysis code SAPIV which is used to determine load cell response. The computed load cell response was then smoothed and differentiated to compute mass flow rate from the system. Comparison between computed mass flow rate at the instrument location and mass flow rate from the system computed from the load cell output was used to evaluate mass flow measurement capability of the load cell weighing system. Results of the analysis indicate that the load cell weighing system will provide reference mass flows more accurately than the instruments now in LOFT

  16. Influence of Base Oil Polarity on the Transient Shear Flow of Biodegradable Lubricating Greases

    Directory of Open Access Journals (Sweden)

    Martin Fiedler

    2015-09-01

    Full Text Available The scope of this study is to elucidate the physical mechanisms influencing the transient flow behavior of lubricating greases based on biogenic oleochemicals from a polarity point of view. This includes the mutually interacting influence of base oil polarity and thickening agents on the rheologically-measured mechanical structural degradation in transient shear flow. Due to the high temperature dependence of Keesom forces in the background of polar-active bond mechanisms, the analysis of the transient flow response as a function of temperature allows to attribute the observed influences to differences in base oil polarity. In general, clay-thickened greases show a greater tendency to be rheologically influenced by base oil polarities than soap-thickened lubricating greases.

  17. Numerical Investigation of Transient Flow in a Prototype Centrifugal Pump during Startup Period

    Science.gov (United States)

    Zhang, Yu-Liang; Zhu, Zu-Chao; Dou, Hua-Shu; Cui, Bao-Ling; Li, Yi; Zhou, Zhao-Zhong

    2017-05-01

    Transient performance of pumps during transient operating periods, such as startup and stopping, has drawn more and more attentions recently due to the growing engineering needs. During the startup period of a pump, the performance parameters such as the flow rate and head would vary significantly in a broad range. Therefore, it is very difficult to accurately specify the unsteady boundary conditions for a pump alone to solve the transient flow in the absence of experimental results. The closed-loop pipe system including a centrifugal pump is built to accomplish the self-coupling calculation. The three-dimensional unsteady incompressible viscous flow inside the passage of the pump during startup period is numerically simulated using the dynamic mesh method. Simulation results show that there are tiny fluctuations in the flow rate even under stable operating conditions and this can be attributed to influence of the rotor-stator interaction. At the very beginning of the startup, the rising speed of the flow rate is lower than that of the rotational speed. It is also found that it is not suitable to predict the transient performance of pumps using the calculation method of quasi-steady flow, especially at the earlier period of the startup.

  18. Simulation of transient fluid flow in mold region during steel continuous casting

    International Nuclear Information System (INIS)

    Liu, R; Thomas, B G; Sengupta, J

    2012-01-01

    A system of models has been developed to study transient flow during continuous casting and applied to simulate an event of multiple stopper-rod movements. It includes four sub-models to incorporate different aspects in this transient event. A three-dimensional (3-D) porous-flow model of the nozzle wall calculates the rate argon gas flow into the liquid steel, and the initial mean bubble size is estimated. Transient CFD models simulate multiphase flow of steel and gas bubbles in the Submerged Entry Nozzle (SEN) and mold and have been validated with experimental data from both nail dipping and Sub-meniscus Velocity Control (SVC) measurements. To obtain the transient inlet boundary conditions for the simulation, two semi-empirical models, a stopper-rod-position based model and a metal-level-based model, predict the liquid steel flow rate through the SEN based on recorded plant data. Finally the model system was applied to study the effects of stopper rod movements on SEN/mold flow patterns. Meniscus level fluctuations were calculated using a simple pressure method and compared well with plant measurements. Insights were gained from the simulation results to explain the cause of meniscus level fluctuations and the formation of sliver defects during stopper rod movements.

  19. Transient simulation in interior flow field of lobe pump

    International Nuclear Information System (INIS)

    Li, Y B; Sang, X H; Shen, H; Jia, K; Meng, Q W

    2013-01-01

    The subject of this paper is mainly focused on the development and control of the double folium and trifolium lobe pump profiles by using the principle of involute engagement and use CAD to get an accurate involute profile. We use the standard k-ε turbulence model and PISO algorithm based on CFD software FLUENT. The dynamic mesh and UDF technology is introduced to simulate the interior flow field inside a lobe pump, and the variation of interior flow field under the condition of the lobe rotating is analyzed. We also analyse the influence produced by the difference in lobes, and then reveal which lobe is best. The results show that dynamic variation of the interior flow field is easily obtained by dynamic mesh technology and the distribution of its pressure and velocity. Because of the small gaps existing between the rotors and pump case, the higher pressure area will flow into the lower area though the small gaps which cause the working area keep with higher pressure all the time. Both of the double folium and trifolium are existing the vortex during the rotting time and its position, size and shape changes all the time. The vortexes even disappear in a circle period and there are more vortexes in double folium lobe pump. The velocity and pressure pulsation of trifolium pump are lower than that of the double folium

  20. Present status of numerical analysis on transient two-phase flow

    International Nuclear Information System (INIS)

    Akimoto, Masayuki; Hirano, Masashi; Nariai, Hideki.

    1987-01-01

    The Special Committee for Numerical Analysis of Thermal Flow has recently been established under the Japan Atomic Energy Association. Here, some methods currently used for numerical analysis of transient two-phase flow are described citing some information given in the first report of the above-mentioned committee. Many analytical models for transient two-phase flow have been proposed, each of which is designed to describe a flow by using differential equations associated with conservation of mass, momentum and energy in a continuous two-phase flow system together with constructive equations that represent transportation of mass, momentum and energy though a gas-liquid interface or between a liquid flow and the channel wall. The author has developed an analysis code, called MINCS, that serves for systematic examination of conservation equation and constructive equations for two-phase flow models. A one-dimensional, non-equilibrium two-liquid flow model that is used as the basic model for the code is described. Actual procedures for numerical analysis is shown and some problems concerning transient two-phase analysis are described. (Nogami, K.)

  1. Single-well push-pull test in transient Forchheimer flow field

    Science.gov (United States)

    Wang, Quanrong; Zhan, Hongbin; Wang, Yanxin

    2017-06-01

    Using the single-well push-pull (SWPP) test to quantify in situ aquifer characteristics associated with solute transport (dispersion coefficient, geobiochemical reaction rates), the accuracy of parameter estimation was not only dependent on the solute transport models but also the groundwater flow models. However, many previous studies on the SWPP test were based on assumptions over-simplifying the flow field, namely, groundwater flow followed Darcy's law; flow was in the steady state during the entire test duration; the wellbore storage could be negligible. In this study, we have carefully examined such assumptions by developing a new finite-difference model of the SWPP test under the transient Forchheimer flow condition, considering the wellbore storage. The SWPP test included an injection phase, a chaser phase, a rest phase, and an extraction phase. The results showed that the concentration of the steady-state flow solution was greater than that of the transient flow solution at the beginning, and its peak value was also greater than that of the transient flow solution. The difference between the breakthrough curves (BTCs) of the transient flow SWPP model and the steady-state flow SWPP model was not negligible, and such a difference increased with the decreasing specific storage. We also found that BTCs were not sensitive to the inertial force coefficient, while they were sensitive to the wellbore storage. BTCs with different radius of the wellbore (rw) were clearly different from each other, and a larger rw resulted in a greater concentration at the well during the extraction phase.

  2. Flow field topology of transient mixing driven by buoyancy

    Science.gov (United States)

    Duval, Walter M B.

    2004-01-01

    Transient mixing driven by buoyancy occurs through the birth of a symmetric Rayleigh-Taylor morphology (RTM) structure for large length scales. Beyond its critical bifurcation the RTM structure exhibits self-similarity and occurs on smaller and smaller length scales. The dynamics of the RTM structure, its nonlinear growth and internal collision, show that its genesis occurs from an explosive bifurcation which leads to the overlap of resonance regions in phase space. This event shows the coexistence of regular and chaotic regions in phase space which is corroborated with the existence of horseshoe maps. A measure of local chaos given by the topological entropy indicates that as the system evolves there is growth of uncertainty. Breakdown of the dissipative RTM structure occurs during the transition from explosive to catastrophic bifurcation; this event gives rise to annihilation of the separatrices which drives overlap of resonance regions. The global bifurcation of explosive and catastrophic events in phase space for the large length scale of the RTM structure serves as a template for which mixing occurs on smaller and smaller length scales. Copyright 2004 American Institute of Physics.

  3. Transient Taylor-Aris dispersion for time-dependent flows in straight channels

    DEFF Research Database (Denmark)

    Vedel, Søren; Bruus, Henrik

    2012-01-01

    Taylor–Aris dispersion, the shear-induced enhancement of solute diffusion in the flow direction of the solvent, has been studied intensely in the past half century for the case of steady flow and single-frequency pulsating flows. Here, combining Aris’s method of moments with Dirac’s bra–ket forma......Taylor–Aris dispersion, the shear-induced enhancement of solute diffusion in the flow direction of the solvent, has been studied intensely in the past half century for the case of steady flow and single-frequency pulsating flows. Here, combining Aris’s method of moments with Dirac’s bra......–ket formalism, we derive an expression for the effective solute diffusivity valid for transient Taylor–Aris dispersion in any given time-dependent, multi-frequency solvent flow through straight channels. Our theory shows that the solute dispersion may be greatly enhanced by the time-dependent parts of the flow...

  4. Validation of a fluid-structure interaction numerical model for predicting flow transients in arteries.

    Science.gov (United States)

    Kanyanta, V; Ivankovic, A; Karac, A

    2009-08-07

    Fluid-structure interaction (FSI) numerical models are now widely used in predicting blood flow transients. This is because of the importance of the interaction between the flowing blood and the deforming arterial wall to blood flow behaviour. Unfortunately, most of these FSI models lack rigorous validation and, thus, cannot guarantee the accuracy of their predictions. This paper presents the comprehensive validation of a two-way coupled FSI numerical model, developed to predict flow transients in compliant conduits such as arteries. The model is validated using analytical solutions and experiments conducted on polyurethane mock artery. Flow parameters such as pressure and axial stress (and precursor) wave speeds, wall deformations and oscillating frequency, fluid velocity and Poisson coupling effects, were used as the basis of this validation. Results show very good comparison between numerical predictions, analytical solutions and experimental data. The agreement between the three approaches is generally over 95%. The model also shows accurate prediction of Poisson coupling effects in unsteady flows through flexible pipes, which up to this stage have only being predicted analytically. Therefore, this numerical model can accurately predict flow transients in compliant vessels such as arteries.

  5. Fission product transport and behavior during two postulated loss of flow transients in the air

    Energy Technology Data Exchange (ETDEWEB)

    Adams, J.P.; Carboneau, M.L.

    1991-01-01

    This document discusses fission product behavior during two postulated loss-of-flow accidents (leading to high- and low-pressure core degradation, respectively) in the Advanced Test Reactor (ATR). These transients are designated ATR Transient LCPI5 (high-pressure) and LPP9 (low-pressure). Normally, transients of this nature would be easily mitigated using existing safety systems and procedures. In these analyses, failure of these safety systems was assumed so that core degradation and fission product release could be analyzed. A probabilistic risk assessment indicated that the probability of occurrence for these two transients is of the order of 10{sup {minus}5 }and 10{sup {minus}7} per reactor year for LCP15 and LPP9, respectively.

  6. Fission product transport and behavior during two postulated loss of flow transients in the air

    Energy Technology Data Exchange (ETDEWEB)

    Adams, J.P.; Carboneau, M.L.

    1991-12-31

    This document discusses fission product behavior during two postulated loss-of-flow accidents (leading to high- and low-pressure core degradation, respectively) in the Advanced Test Reactor (ATR). These transients are designated ATR Transient LCPI5 (high-pressure) and LPP9 (low-pressure). Normally, transients of this nature would be easily mitigated using existing safety systems and procedures. In these analyses, failure of these safety systems was assumed so that core degradation and fission product release could be analyzed. A probabilistic risk assessment indicated that the probability of occurrence for these two transients is of the order of 10{sup {minus}5 }and 10{sup {minus}7} per reactor year for LCP15 and LPP9, respectively.

  7. Equations for transient flow-boiling in a duct

    International Nuclear Information System (INIS)

    Mathers, W.G.; Ferch, R.L.; Hancox, W.T.; McDonald, B.H.

    1981-01-01

    In this paper we derive a separated phase model for weakly coupled flows which extends a model presented elsewhere (BANERJEE, FERCH, MATHERS and McDONALD, 1978). A hyperbolic system of seven partial differential equations results with ensemble-averaged phase velocities, enthalpies and pressures, and void fraction as dependent variables (UVUTUP model). The required constitutive equations for mass, momentum and energy transfer between phases and between the phases and the boundaries are discussed. The relationship of the UVUTUP model to other existing models is also presented

  8. Transient flow in a compressor blade row for a periodic vibration motion

    Science.gov (United States)

    Idres, Moumen; Labanie, Mohamed; Okasha, Mohamed

    2018-01-01

    The goal of this work is to conduct a transient compressor blade row flow simulation as part of blade flutter modeling. An integral step of blade flutter modeling is the calculation of the aerodynamic damping factor as a function of the possible vibration mode shapes. Using Fourier method, the number of blade passages required for transient flow analysis is kept to a minimum of two for all vibration modes. In this work, a compressor rotor blade row is considered. The vibration modes are obtained using ANSYS mechanical, then, unsteady flow is obtained for vibrating blades with a harmonic motion. Work of the flow on the blade is calculated and hence the aerodynamic damping is obtained.

  9. Analysis and computer simulation for transient flow in complex system of liquid piping

    International Nuclear Information System (INIS)

    Mitry, A.M.

    1985-01-01

    This paper is concerned with unsteady state analysis and development of a digital computer program, FLUTRAN, that performs a simulation of transient flow behavior in a complex system of liquid piping. The program calculates pressure and flow transients in the liquid filled piping system. The analytical model is based on the method of characteristics solution to the fluid hammer continuity and momentum equations. The equations are subject to wide variety of boundary conditions to take into account the effect of hydraulic devices. Water column separation is treated as a boundary condition with known head. Experimental tests are presented that exhibit transients induced by pump failure and valve closure in the McGuire Nuclear Station Low Level Intake Cooling Water System. Numerical simulation is conducted to compare theory with test data. Analytical and test data are shown to be in good agreement and provide validation of the model

  10. Investigation of transient flow behaviour in dual-scale porous media with micro particle image velocimetry

    OpenAIRE

    Lundström, Staffan; Nordlund, Markus

    2006-01-01

    Injection processing of composite materials most often includes infiltration of a thermoset resin into a multi-scale porous fabric. Controlling the fluid flow within the multiscale fabric is essential for the quality of the final composite material, since the transport of fluid between regions with different scales plays an important role in phenomena such as void formation and filtration of particle doped resins. In this work, the transient flow behaviour in dual scale porous media is invest...

  11. Transient flow and heat transfer phenomena in inclined wavy films

    Energy Technology Data Exchange (ETDEWEB)

    Serifi, Katerina; Bontozoglou, Vasilis [Department of Mechanical and Industrial Engineering, University of Thessaly, 38334, Volos (Greece); Malamataris, Nikolaos A. [Department of Mechanical Engineering, Technological Educational Institution of Western Macedonia, 50100, Kila Kozani (Greece)

    2004-08-01

    A finite-element numerical scheme is used to study rigorously the flow of an inclined liquid film and the heat transfer from the constant-temperature wall. Regular inlet disturbances are predicted to evolve into periodic or solitary waves depending on the frequency of the forcing. At very low disturbance frequencies parasitic crests appear and the regularity of the wave-train is lost. The effect of a solitary wave-train on heat transfer from the wall is studied, and it is predicted that a stationary temperature distribution develops with periodic flux variation that follows the waves. The thinning of the substrate between successive humps combines with the effect of convection at the crest and tail of the solitary humps to produce heat transfer enhancement significantly above the conduction limit. (authors)

  12. Large Eddy Simulation of Transient Flow, Solidification, and Particle Transport Processes in Continuous-Casting Mold

    Science.gov (United States)

    Liu, Zhongqiu; Li, Linmin; Li, Baokuan; Jiang, Maofa

    2014-07-01

    The current study developed a coupled computational model to simulate the transient fluid flow, solidification, and particle transport processes in a slab continuous-casting mold. Transient flow of molten steel in the mold is calculated using the large eddy simulation. An enthalpy-porosity approach is used for the analysis of solidification processes. The transport of bubble and non-metallic inclusion inside the liquid pool is calculated using the Lagrangian approach based on the transient flow field. A criterion of particle entrapment in the solidified shell is developed using the user-defined functions of FLUENT software (ANSYS, Inc., Canonsburg, PA). The predicted results of this model are compared with the measurements of the ultrasonic testing of the rolled steel plates and the water model experiments. The transient asymmetrical flow pattern inside the liquid pool exhibits quite satisfactory agreement with the corresponding measurements. The predicted complex instantaneous velocity field is composed of various small recirculation zones and multiple vortices. The transport of particles inside the liquid pool and the entrapment of particles in the solidified shell are not symmetric. The Magnus force can reduce the entrapment ratio of particles in the solidified shell, especially for smaller particles, but the effect is not obvious. The Marangoni force can play an important role in controlling the motion of particles, which increases the entrapment ratio of particles in the solidified shell obviously.

  13. Reduced-order modellin for high-pressure transient flow of hydrogen-natural gas mixture

    Science.gov (United States)

    Agaie, Baba G.; Khan, Ilyas; Alshomrani, Ali Saleh; Alqahtani, Aisha M.

    2017-05-01

    In this paper the transient flow of hydrogen compressed-natural gas (HCNG) mixture which is also referred to as hydrogen-natural gas mixture in a pipeline is numerically computed using the reduced-order modelling technique. The study on transient conditions is important because the pipeline flows are normally in the unsteady state due to the sudden opening and closure of control valves, but most of the existing studies only analyse the flow in the steady-state conditions. The mathematical model consists in a set of non-linear conservation forms of partial differential equations. The objective of this paper is to improve the accuracy in the prediction of the HCNG transient flow parameters using the Reduced-Order Modelling (ROM). The ROM technique has been successfully used in single-gas and aerodynamic flow problems, the gas mixture has not been done using the ROM. The study is based on the velocity change created by the operation of the valves upstream and downstream the pipeline. Results on the flow characteristics, namely the pressure, density, celerity and mass flux are based on variations of the mixing ratio and valve reaction and actuation time; the ROM computational time cost advantage are also presented.

  14. Analysis for transient temperature distribution two phase flow using test section QUEEN-02

    International Nuclear Information System (INIS)

    Ainur Rosidi; Joko Prasetio; Edy Sumarno; Kiswanta; Heru Bambang

    2013-01-01

    Experiments on the transient temperature distribution using a two-phase flow test facility QUEEN-02 and BETA test loop was conducted. Purpose of the experiment is to study temperature distribution during the transient cooling process. Experiments performed with the variation of the initial temperature of hot rod test section QUEEN-02 of 350 °C and 500 °C as well as the flow of cooling water temperature is 90 °C with the direction of flow from the bottom up from the BETA test loop. The analysis shows that temperature have the same downward trend in its every point thermocouple for the same initial temperature during cooling. Initial temperature of 350 °C hot rods produced when temperatures drop to 90 °C (the same as the temperature of the cooling water) for 78 seconds while the initial temperature of 500 °C produces hot rod drop time 190 seconds. (author)

  15. Transient flow assurance for determination of operational control of heavy oil pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Cabrejo, Victor [TransCanada Pipelines Ltd, (Canada); Mohitpour, Mo [Tempsys Pipeline Solutions Inc., (Canada)

    2010-07-01

    Pipeline transmission systems have been designed traditionally using steady state simulations. Steady state simulation provided sufficient values for simple systems, but is limited in dealing with surges in flow rates, loss of facilities and facility operation. A dynamic approach is required to test the capacity of a system for various fluids. This paper investigated the use of transient analysis of liquid pipelines in order to improve the design of these pipelines and to achieve operational benefits. The transient method and its use are discussed. Dynamic analysis was applied to the Keystone Pipeline Project. The purpose of the study was first to determine the system capacity and data for transportation of Heavy DilBit, and then to implement batch transportation of a volume of synthetic crude oil. It was found that the use of transient modeling in design and operational assessment of a liquid pipeline ensures system capability, control, safety and integrity.

  16. Mountain scale modeling of transient, coupled gas flow, heat transfer and carbon-14 migration

    International Nuclear Information System (INIS)

    Lu, Ning; Ross, B.

    1993-01-01

    We simulate mountain-scale coupled heat transfer and gas flow at Yucca Mountain. A coupled rock-gas flow and heat transfer model, TGIF2, is used to simulate mountain-scale two-dimensional transient heat transfer and gas flow. The model is first verified against an analytical solution for the problem of an infinite horizontal layer of fluid heated from below. Our numerical results match very well with the analytical solution. Then, we obtain transient temperature and gas flow distributions inside the mountain. These distributions are used by a transient semianalytical particle tracker to obtain carbon-14 travel times for particles starting at different locations within the repository. Assuming that the repository is filled with 30-year-old waste at an initial areal power density of 57 kw/acre, we find that repository temperatures remain above 60 degrees C for more than 10,000 years. Carbon-14 travel times to the surface are mostly less than 1000 years, for particles starting at any time within the first 10,000 years

  17. Effect of rolling motion on transient flow resistance of two-phase flow in a narrow rectangular duct

    International Nuclear Information System (INIS)

    Jin, Guangyuan; Yan, Changqi; Sun, Licheng; Xing, Dianchuan

    2014-01-01

    Highlight: • The frictional resistance in narrow rectangular channel in rolling motion is studied. • Homogeneous correlations could predict the experimental data in vertical condition. • Increasing the two-phase velocity would weaken the fluctuation of friction factor. • The frictional factor has a great similarity with the frictional pressure drop. - Abstract: As a typical ocean environment, rolling motion can induce additional forces on a flow system. Experimental study of the characteristics of air–water mixture flow resistance in narrow rectangular channel(40 × 1.41 mm 2 ) in rolling motions was carried out with the rolling periods and amplitudes of 8 s, 12 s, 16 s, and 10°, 15°, 30°, respectively. Several homogeneous and separated flow models were evaluated against the experimental data to clarify their applicability in predicting the two-phase flow resistance in vertical rectangular channels. The comparison showed that McAdams correlation for calculating the viscosity in homogeneous model is suitable for the present situation to calculate the averaged two-phase flow resistance. Transient flow resistance under rolling condition changed periodically, as a result, attempt was conducted to illustrate the effect of rolling motion. Transient frictional pressure drop strongly depends on the mass quality, Reynolds number, rolling period and amplitude. The fluctuation amplitude of the frictional pressure drop increased with increasing mass quality and rolling amplitude. It also increased with reduction of the rolling period. A new correlation for predicting the transient frictional factor was given by including the influence of rolling parameters and was validated against the experimental data

  18. Instrumentation to Monitor Transient Periodic Developing Flow in Non-Newtonian Slurries

    Energy Technology Data Exchange (ETDEWEB)

    Bamberger, Judith A.; Enderlin, Carl W.

    2013-11-15

    Staff at Pacific Northwest National Laboratory have conducted mixing and mobilization experiments with non-Newtonian slurries that exhibit Bingham plastic and shear thinning behavior and shear strength. This paper describes measurement techniques applied to identify the interface between flowing and stationary regions of non-Newtonian slurries that are subjected to transient, periodic, developing flows. Techniques were developed to identify the boundary between the flowing and stationary regions, time to mix, characteristic velocities of the flow field produced by the symmetrically spaced nozzles, and the velocity of the upwell formed in the center of the tank by the intersection of flow from four symmetrically spaced nozzles that impinge upon the tank floor. Descriptions of the instruments and instrument performance are presented. These techniques were an effective approach to characterize mixing phenomena, determine mixing energy required to fully mobilize vessel contents and to determine mixing times for process evaluation.

  19. Effect of vortex generators on the closing transient flow of bileaflet mechanical heart valves

    Science.gov (United States)

    Murphy, David; Dasi, Lakshmi; Yoganathan, Ajit; Glezer, Ari

    2006-11-01

    The time-periodic closing of bileaflet mechanical heart valves is accompanied by a strong flow transient that is associated with the formation of a counter-rotating vortex pair near the b-datum line of leaflet edges. The strong transitory shear that is generated by these vortices may be damaging to blood elements and may result in platelet activation. In the present work, these flow transients are mitigated using miniature vortex generator arrays that are embedded on the surface of the leaflets. Two vortex generator designs were investigated: one design comprised staggered rectangular fins and the other one staggered hemispheres. The closing transients in the absence and presence of the passive vortex generators are characterized using phase locked PIV measurements. The study utilizes a 25 mm St. Jude Medical valve placed in the aortic position of the Georgia Tech left heart simulator. Measurements of the velocity field in the center plane of the leaflets demonstrate that the dynamics of the transient vortices that precede the formation of the leakage jets can be significantly altered and controlled by relatively simple passive modifications of existing valve designs. Human blood experiments validated the effectiveness of miniature vortex generators in reducing thrombus formation by over 42 percent.

  20. CFD investigation of flow inversion in typical MTR research reactor undergoing thermal-hydraulic transients

    International Nuclear Information System (INIS)

    Salama, Amgad

    2011-01-01

    Highlights: → The 3D, CFD simulation of FLOFA accident in the generic IAEA 10 MW research reactor is carried out. → The different flow and heat transfer mechanisms involved in this process were elucidated. → The transition between these mechanisms during the course of FLOFA is discussed and investigated. → The interesting inversion process upon the transition from downward flow to upward flow is shown. → The temperature field and the friction coefficient during the whole transient process were shown. - Abstract: Three dimensional CFD full simulations of the fast loss of flow accident (FLOFA) of the IAEA 10 MW generic MTR research reactor are conducted. In this system the flow is initially downward. The transient scenario starts when the pump coasts down exponentially with a time constant of 1 s. As a result the temperatures of the heating element, the clad, and the coolant rise. When the flow reaches 85% of its nominal value the control rod system scrams and the power drops sharply resulting in the temperatures of the different components to drop. As the coolant flow continues to drop, the decay heat causes the temperatures to increase at a slower rate in the beginning. When the flow becomes laminar, the rate of temperature increase becomes larger and when the pumps completely stop a flow inversion occurs because of natural convection. The temperature will continue to rise at even higher rates until natural convection is established, that is when the temperatures settle off. The interesting 3D patterns of the flow during the inversion process are shown and investigated. The temperature history is also reported and is compared with those estimated by one-dimensional codes. Generally, very good agreement is achieved which provides confidence in the modeling approach.

  1. Ambiguous hydraulic heads and 14C activities in transient regional flow.

    Science.gov (United States)

    Schwartz, Franklin W; Sudicky, Edward A; McLaren, Robert G; Park, Young-Jin; Huber, Matthew; Apted, Mick

    2010-01-01

    A regional flow and transport model is used to explore the implications of significant variability in Pleistocene and Holocene climates on hydraulic heads and (14)C activity. Simulations involve a 39 km slice of the Death Valley Flow System through Yucca Mountain toward the Amargosa Desert. The long-time scale over which infiltration has changed (tens-of-thousands of years) is matched by the large physical extent of the flow system (many tens-of-kilometers). Estimated paleo-infiltration rates were estimated using a juniper pollen percentage that extends from the last interglacial (LIG) period (approximately 120 kyrbp) to present. Flow and (14)C transport simulations show that groundwater flow changes markedly as a function of paleoclimate. At the last glacial maximum (LGM, 21 kyrbp), the recharge to the flow system was about an order-of-magnitude higher than present, and water table was more than 100 m higher. With large basin time constants, flow is complicated because hydraulic heads at a given location reflect conditions of the past, but at another location the flow may reflect present conditions. This complexity is also manifested by processes that depend on flow, for example (14)C transport. Without a model that accounts for the historical transients in recharge for at least the last 20,000 years, there is no simple way to deconvolve the (14)C dates to explain patterns of flow.

  2. Analysis on accident transient of complete loss of forced reactor coolant flow in AP1000

    International Nuclear Information System (INIS)

    Jing Jianping; Zhang Chunming; Sun Wei; An Jieru; Jia Bin

    2014-01-01

    AP1OOO reactor is a typical third generation nuclear power plant at present in the world. The primary system of AP10OO nuclear power plant was modeled by using RELAP5/MOD 3.3 code, and the transient thermal hydraulic characteristics were analyzed under the accident sequence of complete loss of forced reactor coolant flow. The calculation results by RELAP5 code were compared with those of the COAST and LOFTRAN codes. The distributions by RELAP5 code were consistent with those of the COAST and LOFTRAN codes. The study results show that the RELAP5 model can accurately simulate the transient thermal hydraulic characteristics of AP1OOO under the accident of complete loss of forced reactor coolant flow. (authors)

  3. Determination of Unsaturated Soil Hydraulic Properties by Transient Flow Experiments and Parameter Estimation

    OpenAIRE

    Kohno, Iichiro; Nishigaki, Makoto; Takeshita, Yuji

    1989-01-01

    The numerical feasibility of determining soil water retention and hydraulic conductivity functions simultaneously from one-dimensional transient flow experiments in the laboratory by parameter estimation method is evaluated. Soil hydraulic properties are assumed to be represented by van Genuchten's closed-form expressions involving two unknown parameters: coefficients α and n . These parameters are evaluated by nonlinear least-squares fitting of predicted and observed pressure head with...

  4. Workshop `Measurement technology for steady state and transient multi phase flows`; Workshop `Messtechnik fuer stationaere und transiente Mehrphasenstroemungen`

    Energy Technology Data Exchange (ETDEWEB)

    Prasser, H.M. [ed.

    1997-12-01

    There is hardly another area of physics which has a comparable multiplicity of phenomena, like flow in multi-phase mixtures. The wishes of experimenters regarding measurement technique are correspondingly great: Apart from the conventional parameters of pressure, temperature and speed of flow, as great a collection with resolution of the instantaneous phase distribution is required. Also, the phases themselves frequently consists of several components, whose concentration should also be measured. The enormous progress which has recently been made with laser optics and tomographic processes, must be compared with a long list of unsolved problems, above all where non-contact measurement is concerned. The attempts at solutions are multifarious, the need for the exchange of experience is great and the comparson of measurement processes with one another must be strengthened. The workshop has set itself these targets. (orig.) [Deutsch] Es gibt kaum ein anderes Gebiet der Physik, das eine vergleichbare Vielfalt der Erscheinungen aufweist wie Stroemungen von Mehrphasengemischen. Entsprechend gross sind die Wuensche der Experimentatoren hinsichtlich der Messtechnik: Neben den klassischen Parametern Druck, Temperatur und Stroemungsgeschwindigkeit wird eine moeglichst hoch aufloesende Erfassung der momentanen Phasenverteilung benoetigt. Ausserdem bestehen die Phasen selbst haeufig aus mehreren Komponenten, deren Konzentration ebenfalls gemessen werden soll. Den enormen Fortschritten, ie mit laseroptischen und tomographischen Verfahren in letzter Zeit gemacht wurden, steht nach wie vor eine lange Liste bisher ungeloester Aufgaben gegenueber, vor allen Dingen, wenn beruehrungslos gemessen werden soll. Die Loesungsansaetze sind vielfaeltig, der Bedarf an Erfahrungsaustausch ist gross, der Vergleich der Messverfahren untereinander muss verstaerkt werden. Diesen Zielen hatte sich der Workshop ``Messtechnik fuer tationaere und transiente Mehrphasenstroemungen`` verschrieben.

  5. On the quantification and visualization of transient periodic instabilities in pulsatile flows.

    Science.gov (United States)

    Khan, Muhammad Owais; Chnafa, Christophe; Gallo, Diego; Molinari, Filippo; Morbiducci, Umberto; Steinman, David A; Valen-Sendstad, Kristian

    2017-02-08

    Turbulent-like flows without cycle-to-cycle variations are more frequently being reported in studies of cardiovascular flows. The associated stimuli might be of mechanobiological relevance, but how to quantify them objectively is not obvious. Classical Reynolds decomposition, where the flow is separated into mean and fluctuating velocity components, is not applicable as the phase-average is zero. We therefore expanded on established techniques and present the idea, analogous to Reynolds decomposition, to decompose a flow with transient instabilities into low- versus high frequency components, respectively, to discriminate flow instabilities from the underlying cardiac pulsatility. Transient wall shear stress and velocity signals derived from computational fluid dynamic simulations were transferred to the frequency domain. A high-pass filter was applied to subtract the 99% most-energy-containing frequencies, which gave a cut-off frequency of 25Hz. We introduce here the spectral power index, and compute the fluctuating kinetic energy, based on the high-pass filtered velocity components, both being frequency-based operators. The efficacy was evaluated in an aneurysm model for multiple flow rates demonstrating transition to turbulent-like flows. The frequency-based operators were found to better correlate with the qualitatively observed flow instabilities compared to conventional descriptors, like time-averaged wall shear stress or oscillatory shear index. We demonstrate how the high frequencies beyond the physiological range could be analyzed and/or transferred back to the time domain for quantification and visualization purposes. We have introduced general frequency-based operators, easily extendable to other cardiovascular territories based on a posteriori heuristic filtering that allows for separation, isolation, and quantification of cycle-invariant turbulent-like flows. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Influence of transient strain rates on material flow stress and microstructure evolution

    Science.gov (United States)

    Dierdorf, Jens; Lohmar, Johannes; Hirt, Gerhard

    2017-10-01

    A comprehensive knowledge about the material flow stress is a key parameter for a reliable design of hot forming processes using Finite Element (FE) software codes. Due to the microstructure evolution caused by the interaction of hardening and softening phenomena that take place during hot forming operations, the material flow stress is influenced by strain rate and temperature. While transient strain rates and temperatures typically characterize the industrial forming processes, the flow curves used in FE simulations are normally determined at arbitrary constant temperatures and strain rates. To calculate the flow stress evolution in between the measured strain rates, FE programs use linear interpolation. Hence, the material relaxation behavior caused by the microstructure evolution during transient strain rates is not considered. Previous investigations by various authors have shown that for a rapid strain rate change by one order of magnitude significant deviations between measured flow stress and linear interpolation appear before the flow stress approximates the flow curve obtained at the new constant strain rate again. However as mentioned before, industrial forming processes are characterized by more or less smooth than instantaneous changes in strain rate. Therefore, in this study, changing strain rates with different linear slopes are investigated. For this purpose, isothermal cylinder compression tests of an industrial case hardening steel are conducted at elevated temperatures. The resulting flow stress is compared with the linear interpolation of the flow curves determined at constant strain rates. Additionally, the grain size evolution during the strain rate change is analyzed to better understand the microstructural changes. The current investigation shows that the slope of the strain rate increase significantly influences the deviation from the linear interpolation. This observation can be explained by the time dependent microstructure evolution

  7. Colloid-facilitated transport of cesium in vadose-zone sediments: the importance of flow transients.

    Science.gov (United States)

    Cheng, Tao; Saiers, James E

    2010-10-01

    Colloid-sized particles are commonly detected in vadose-zone pore waters and are capable of binding chemicals with sorptive affinities for geologic materials. Published research demonstrates that colloids are capable of facilitating the transport of sorptive contaminants under conditions of steady pore water flow, when volumetric moisture content and pore water velocity are constant. Less is known about the role of colloids in governing contaminant mobility under transient-flow conditions, which are characteristic of natural vadose-zone environments. The objective of this study is to elucidate the influences of flow transients on the mobilization and transport of in situ colloids and colloid-associated contaminants. We conducted column experiments in which the mobilization of in situ colloids and (137)Cs was induced by transients associated with the drainage and imbibition of (137)Cs contaminated-sediments. Our results demonstrate that substantial quantities of in situ colloids and colloid-associated (137)Cs are mobilized as volumetric moisture content declines during porous-medium drainage and as volumetric moisture content increases during porous-medium imbibition. We also find that the colloid-effect on (137)Cs transport is sensitive to changes in pore water ionic strength. That is, the quantities of colloids mobilized and the capacity of the these colloids to bind (137)Cs decrease with increasing ionic strength, leading to a decrease of the mass of (137)Cs eluted from the columns during porous-medium drainage and imbibition.

  8. Transient response in granular quasi-two-dimensional bounded heap flow

    Science.gov (United States)

    Xiao, Hongyi; Ottino, Julio M.; Lueptow, Richard M.; Umbanhowar, Paul B.

    2017-10-01

    We study the transition between steady flows of noncohesive granular materials in quasi-two-dimensional bounded heaps by suddenly changing the feed rate. In both experiments and simulations, the primary feature of the transition is a wedge of flowing particles that propagates downstream over the rising free surface with a wedge front velocity inversely proportional to the square root of time. An additional longer duration transient process continues after the wedge front reaches the downstream wall. The entire transition is well modeled as a moving boundary problem with a diffusionlike equation derived from local mass balance and a local relation between the flux and the surface slope.

  9. Finite element analysis of transient viscous flow with free surface using filling pattern technique

    International Nuclear Information System (INIS)

    Kim, Ki Don; Yang, Dong Yol; Jeong, Jun Ho

    2001-01-01

    The filling pattern technique based on the finite element method and Eulerian mesh advancement approach has been developed to analyze incompressible transient viscous flow with free surfaces. The governing equation for flow analysis is Navier-Stokes equation including inertia and gravity effects. The penalty and predictor-corrector methods are used effectively for finite element formulation. The flow front surface and the volume inflow rate are calculated using the filling pattern technique to select an adequate pattern among four filling patterns at each triangular control volume. Using the proposed numerical technique, the collapse of a dam has been analyzed to predict flow phenomenon of fluid and the predicted front positions versus time have been compared with the reported experimental result

  10. Lagrangian-based investigation of the transient flow structures around a pitching hydrofoil

    Science.gov (United States)

    Wu, Qin; Huang, Biao; Wang, Guoyu

    2016-02-01

    The objective of this paper is to address the transient flow structures around a pitching hydrofoil by combining physical and numerical studies. In order to predict the dynamic behavior of the flow structure effectively, the Lagrangian coherent structures (LCS) defined by the ridges of the finite-time Lyapunov exponent (FTLE) are utilized under the framework of Navier-Stokes flow computations. In the numerical simulations, the k-ω shear stress transport (SST) turbulence model, coupled with a two-equation γ {-Re}_θ transition model, is used for the turbulence closure. Results are presented for a NACA66 hydrofoil undergoing slowly and rapidly pitching motions from 0° to 15° then back to 0° at a moderate Reynolds number Re=7.5× 105. The results reveal that the transient flow structures can be observed by the LCS method. For the slowly pitching case, it consists of five stages: quasi-steady and laminar, transition from laminar to turbulent, vortex development, large-scale vortex shedding, and reverting to laminar. The observation of LCS and Lagrangian particle tracers elucidates that the trailing edge vortex is nearly attached and stable during the vortex development stage and the interaction between the leading and trailing edge vortex caused by the adverse pressure gradient forces the vortexes to shed downstream during the large-scale vortex shedding stage, which corresponds to obvious fluctuations of the hydrodynamic response. For the rapidly pitching case, the inflection is hardly to be observed and the stall is delayed. The vortex formation, interaction, and shedding occurred once instead of being repeated three times, which is responsible for just one fluctuation in the hydrodynamic characteristics. The numerical results also show that the FTLE field has the potential to identify the transient flows, and the LCS can represent the divergence extent of infinite neighboring particles and capture the interface of the vortex region.

  11. Investigation into Transient Flow in a Centrifugal Pump with Wear Ring Clearance Variation

    Directory of Open Access Journals (Sweden)

    Houlin Liu

    2014-04-01

    Full Text Available The leakage flow paths in the sidewall gaps of centrifugal pumps are of significant importance for numbers of effects. The paper is concerned with the transient flow in the leakage flow paths with wear ring clearance variation. For this purpose, numerical simulations of the whole pump were carried out. The grid dependence and yplus check were performed first. Additionally, experimental data of performance characteristic and pressure fluctuation inside the sidewall gap was used to validate the numerical results. The transient velocity fields inside the sidewall gaps during one blade passage period were simulated. And the leakage through the wear ring gap was obtained for all operating points investigated. To have a better idea of attenuation and propagation of pressure inside the sidewall gap, the unsteady pressure distributions in the gap were calculated. Additionally, the surfaces of the impeller were divided into four parts. The fluid force on each part was expressed as a percentage of the total radial force. Through comparing the flow fields, the pressure distributions, and the radial force between the pumps with different wear ring clearances, the effects of the wear ring clearance were discussed in detail. The results can be used to guide the optimum design of the pump sidewall gaps.

  12. Transient molecular orientation and rheology in flow aligning thermotropic liquid crystalline polymers

    International Nuclear Information System (INIS)

    Ugaz, Victor M.; Burghardt, Wesley R.; Zhou, Weijun; Kornfield, Julia A.

    2001-01-01

    Quantitative measurements of molecular orientation and rheology are reported for various transient shear flows of a nematic semiflexible copolyether. Unlike the case of lyotropic liquid crystalline polymers (LCPs), whose structure and rheology in shear are dominated by director tumbling, this material exhibits flow aligning behavior. The observed behavior is quite similar to that seen in a copolyester that we have recently studied [Ugaz and Burghardt (1998)], suggesting that flow aligning dynamics may predominate in main-chain thermotropes that incorporate significant chain flexibility. Since the flow aligning regime has received little attention in previous attempts to model the rheology of textured, polydomain LCPs, we attempt to determine whether available models are capable of predicting the orientation and stress response of this class of LCP. We first examine the predictions of the polydomain Ericksen model, an adaptation of Ericksen's transversely isotropic fluid model which accounts for the polydomain distribution of director orientation while neglecting distortional elasticity. This simple model captures a number of qualitative and quantitative features associated with the evolution of orientation and stress during shear flow inception, but cannot cope with reversing flows. To consider the possible role of distortional elasticity in the re-orientation dynamics upon reversal, we evaluate the mesoscopically averaged domain theory of Larson and Doi [Larson and Doi (1991)], which incorporates a phenomenological description of distortional elastic effects. To date, their approach to account for polydomain structure has only been applied to describe tumbling LCPs. We find that it captures the qualitative transient orientation response to flow reversals, but is less successful in describing the evolution of stresses. This is linked to the decoupling approximation adopted during the model's development. Finally, a modified polydomain Ericksen model is introduced

  13. One-dimensional transient unequal velocity two-phase flow by the method of characteristics

    International Nuclear Information System (INIS)

    Rasouli, F.

    1981-01-01

    An understanding of two-phase flow is important when one is analyzing the accidental loss of coolant or when analyzing industrial processes. If a pipe in the steam generator of a nuclear reactor breaks, the flow will remain critical (or choked) for almost the entire blowdown. For this reason the knowledge of the two-phase maximum (critical) flow rate is important. A six-equation model--consisting of two continuity equations, two energy equations, a mixture momentum equation, and a constitutive relative velocity equation--is solved numerically by the method of characteristics for one-dimensional, transient, two-phase flow systems. The analysis is also extended to the special case of transient critical flow. The six-equation model is used to study the flow of a nonequilibrium sodium-argon system in a horizontal tube in which the nonequilibrium sodium-argon system in a horizontal tube in which the critical flow condition is at the entrance. A four-equation model is used to study the pressure-pulse propagation rate in an isothermal air-water system, and the results that are found are compared with the experimental data. Proper initial and boundary conditions are obtained for the blowdown problem. The energy and mass exchange relations are evaluated by comparing the model predictions with results of void-fraction and heat-transfer experiments. A simplified two-equation model is obtained for the special case of two incompressible phases. This model is used in the preliminary analysis of batch sedimentation. It is also used to predict the shock formation in the gas-solid fluidized bed

  14. Efficient geostatistical inversion of transient groundwater flow using preconditioned nonlinear conjugate gradients

    Science.gov (United States)

    Klein, Ole; Cirpka, Olaf A.; Bastian, Peter; Ippisch, Olaf

    2017-04-01

    In the geostatistical inverse problem of subsurface hydrology, continuous hydraulic parameter fields, in most cases hydraulic conductivity, are estimated from measurements of dependent variables, such as hydraulic heads, under the assumption that the parameter fields are autocorrelated random space functions. Upon discretization, the continuous fields become large parameter vectors with O (104 -107) elements. While cokriging-like inversion methods have been shown to be efficient for highly resolved parameter fields when the number of measurements is small, they require the calculation of the sensitivity of each measurement with respect to all parameters, which may become prohibitive with large sets of measured data such as those arising from transient groundwater flow. We present a Preconditioned Conjugate Gradient method for the geostatistical inverse problem, in which a single adjoint equation needs to be solved to obtain the gradient of the objective function. Using the autocovariance matrix of the parameters as preconditioning matrix, expensive multiplications with its inverse can be avoided, and the number of iterations is significantly reduced. We use a randomized spectral decomposition of the posterior covariance matrix of the parameters to perform a linearized uncertainty quantification of the parameter estimate. The feasibility of the method is tested by virtual examples of head observations in steady-state and transient groundwater flow. These synthetic tests demonstrate that transient data can reduce both parameter uncertainty and time spent conducting experiments, while the presented methods are able to handle the resulting large number of measurements.

  15. Transient flows of the solar wind associated with small-scale solar activity in solar minimum

    Science.gov (United States)

    Slemzin, Vladimir; Veselovsky, Igor; Kuzin, Sergey; Gburek, Szymon; Ulyanov, Artyom; Kirichenko, Alexey; Shugay, Yulia; Goryaev, Farid

    The data obtained by the modern high sensitive EUV-XUV telescopes and photometers such as CORONAS-Photon/TESIS and SPHINX, STEREO/EUVI, PROBA2/SWAP, SDO/AIA provide good possibilities for studying small-scale solar activity (SSA), which is supposed to play an important role in heating of the corona and producing transient flows of the solar wind. During the recent unusually weak solar minimum, a large number of SSA events, such as week solar flares, small CMEs and CME-like flows were observed and recorded in the databases of flares (STEREO, SWAP, SPHINX) and CMEs (LASCO, CACTUS). On the other hand, the solar wind data obtained in this period by ACE, Wind, STEREO contain signatures of transient ICME-like structures which have shorter duration (<10h), weaker magnetic field strength (<10 nT) and lower proton temperature than usual ICMEs. To verify the assumption that ICME-like transients may be associated with the SSA events we investigated the number of weak flares of C-class and lower detected by SPHINX in 2009 and STEREO/EUVI in 2010. The flares were classified on temperature and emission measure using the diagnostic means of SPHINX and Hinode/EIS and were confronted with the parameters of the solar wind (velocity, density, ion composition and temperature, magnetic field, pitch angle distribution of the suprathermal electrons). The outflows of plasma associated with the flares were identified by their coronal signatures - CMEs (only in few cases) and dimmings. It was found that the mean parameters of the solar wind projected to the source surface for the times of the studied flares were typical for the ICME-like transients. The results support the suggestion that weak flares can be indicators of sources of transient plasma flows contributing to the slow solar wind at solar minimum, although these flows may be too weak to be considered as separate CMEs and ICMEs. The research leading to these results has received funding from the European Union’s Seventh Programme

  16. A Guide for Using the Transient Ground-Water Flow Model of the Death Valley Regional Ground-Water Flow System, Nevada and California

    Energy Technology Data Exchange (ETDEWEB)

    Joan B. Blainey; Claudia C. Faunt, and Mary C. Hill

    2006-05-16

    This report is a guide for executing numerical simulations with the transient ground-water flow model of the Death Valley regional ground-water flow system, Nevada and California using the U.S. Geological Survey modular finite-difference ground-water flow model, MODFLOW-2000. Model inputs, including observations of hydraulic head, discharge, and boundary flows, are summarized. Modification of the DVRFS transient ground-water model is discussed for two common uses of the Death Valley regional ground-water flow system model: predictive pumping scenarios that extend beyond the end of the model simulation period (1998), and model simulations with only steady-state conditions.

  17. Numerical Simulation of Transient Flows around a 3D Pitching Hydrofoil

    Directory of Open Access Journals (Sweden)

    Qin Wu

    2015-02-01

    Full Text Available The objective of this paper is to investigate the hydrodynamic characteristics of the transient flows around a 3D pitching hydrofoil via numerical studies, where the effects of tunnel wall boundary layer and gap flows are considered. Simulations are performed using an unsteady Reynolds Average Navier-Stokes solver and the k-ω SST turbulence model, coupled with a two-equation γ-Reθ transition model. Hydrodynamic forces and flow structures are compared to the results with the equivalent 2D computations. During the upward pitching stage, the transition phenomenon is accurately captured by both the 2D and 3D simulations. The slightly lower lift and suction side loading coefficients predicted by the 3D simulation are due to the pressure effects caused by the tip gap flow. During the dynamic stall stage, the 2D case exhibits a clear overshoot on the hydrodynamic force coefficients and the 3D simulation results better agree with the experimental results. During the downward pitching stage, the flow transitions back to laminar. As for the effect of gap flow and the wall boundary condition, the gap flow causes disturbances to the formation and development of the vortex structures, resulting in the complex distribution of the three-dimensional streamlines and the particle path.

  18. Adaptive Time Stepping for Transient Network Flow Simulation in Rocket Propulsion Systems

    Science.gov (United States)

    Majumdar, Alok K.; Ravindran, S. S.

    2017-01-01

    Fluid and thermal transients found in rocket propulsion systems such as propellant feedline system is a complex process involving fast phases followed by slow phases. Therefore their time accurate computation requires use of short time step initially followed by the use of much larger time step. Yet there are instances that involve fast-slow-fast phases. In this paper, we present a feedback control based adaptive time stepping algorithm, and discuss its use in network flow simulation of fluid and thermal transients. The time step is automatically controlled during the simulation by monitoring changes in certain key variables and by feedback. In order to demonstrate the viability of time adaptivity for engineering problems, we applied it to simulate water hammer and cryogenic chill down in pipelines. Our comparison and validation demonstrate the accuracy and efficiency of this adaptive strategy.

  19. Loss-of-flow transient characterization in carbide-fueled LMFBRs

    Science.gov (United States)

    Rothrock, R. B.; Morgan, M. M.; Baars, R. E.; Elson, J. S.; Wray, M. L.

    One of the benefits derived from the use of carbide fuel in advanced liquid metal fast breeder reactors (LMFBRs) is a decreased vulnerability to certaiin accidents. This can be achieved through the combination of advanced fuel performance with the enhanced reactivity feedback effects and passive shutdown cooling systems characteristic of the current inherently safe plant concepts. The calculated core response to an unprotected loss of flow (ULOF) accident has frequently been used as a benchmark test of these designs, and the advantages of a high-conductivity fuel in relation to this type of transient have been noted in previous analyses. To evaluate this benefit in carbide-fueled LMFBRs incorporating representative current plant design features, limited calculations have been made of a ULOF transient in a small (modular) carbide-fueled LMFBR.

  20. Investigation on transient flow of a centrifugal charging pump in the process of high pressure safety injection

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Fan, E-mail: zhangfan4060@gmail.com; Yuan, Shouqi; Fu, Qiang; Tao, Yi

    2015-11-15

    Highlights: • The transient flow characteristics of the charging pump with the first stage impeller in the HPSI process have been investigated numerically by CFD. • The hydraulic performance of the charging pump during the HPSI are discussed, andthe absolute errors between the simulated and measured results are analyzed in the paper. • Pressure fluctuation in the impeller and flow pattern in the impeller were studied in the HPSI process. It is influenced little at the beginning of the HPSI process while fluctuates strongly in the end of the HPSI process. - Abstract: In order to investigate the transient flow characteristics of the centrifugal charging pump during the transient transition process of high pressure safety injection (HPSI) from Q = 148 m{sup 3}/h to Q = 160 m{sup 3}/h, numerical simulation and experiment are implemented in this study. The transient flow rate, which is the most important factor, is obtained from the experiment and works as the boundary condition to accurately accomplish the numerical simulation in the transient process. Internal characteristics under the variable operating conditions are analyzed through the transient simulation. The results shows that the absolute error between the simulated and measured heads is less than 2.26% and the absolute error between the simulated and measured efficiency is less than 2.04%. Pressure fluctuation in the impeller is less influenced by variable flow rate in the HPSI process, while flow pattern in the impeller is getting better and better with the flow rate increasing. As flow rate increases, fluid blocks on the tongue of the volute and it strikes in this area at large flow rate. Correspondingly, the pressure fluctuation is intense and vortex occurs gradually during this period, which obviously lowers the efficiency of the pump. The contents of the current work can provide references for the design optimization and fluid control of the pump used in the transient process of variable operating

  1. Multi-level adaptive simulation of transient two-phase flow in heterogeneous porous media

    KAUST Repository

    Chueh, C.C.

    2010-10-01

    An implicit pressure and explicit saturation (IMPES) finite element method (FEM) incorporating a multi-level shock-type adaptive refinement technique is presented and applied to investigate transient two-phase flow in porous media. Local adaptive mesh refinement is implemented seamlessly with state-of-the-art artificial diffusion stabilization allowing simulations that achieve both high resolution and high accuracy. Two benchmark problems, modelling a single crack and a random porous medium, are used to demonstrate the robustness of the method and illustrate the capabilities of the adaptive refinement technique in resolving the saturation field and the complex interaction (transport phenomena) between two fluids in heterogeneous media. © 2010 Elsevier Ltd.

  2. Influence of transient flow on the mobility of strontium in unsaturated sand column

    International Nuclear Information System (INIS)

    Mazet, P.

    2008-10-01

    The reactive transport of 85 Sr was studied on laboratory columns, focusing on the influence of transient unsaturated flow (cycles of infiltration and redistribution) associated with controlled geochemistry (constant concentrations of major elements and stable strontium in water). An original experimental tool (gamma attenuation system) allows us to follow at the same time the variations of humidity of the soil and the migration of radionuclide, in a non-destroying and definite way. First stage of this study concerned the implementation of the experimental tool to measure transient hydraulic events within the columns of sand. Several experiments of transport of 85 Sr were then performed with different water condition (saturated, unsaturated, permanent and transient flow). Experimental results were simulated using the computer codes HYDRUS-1D (phenomenological approach with partition coefficient K d ) and HYTEC (mechanistic geochemical/transport approach). Confrontation between experience and modelling shows that, for our operating conditions, transfer of 85 Sr can be predicted with an 'operational' approach using: 1) simplified geochemical model with partition coefficient K d concerning interactive reaction with the soil (K d value determined independently on saturated column, with the same water geochemistry), 2) permanent saturated (or unsaturated) flow, taking into account the cumulated infiltrated water during unsaturated transient hydraulic events concerning hydrodynamic. Generalization of these results (area of validity) suggests that the 'cumulated infiltrated water + K d ' approach can be use, for controlled water geochemistry, when the numerical value of K d is fairly strong (K d ≥≥1), and that it is insensitive to the value of the water content. Moreover, the presence of immobile water (∼10%) recorded with tritium transport, is undetectable with strontium. Explanation of this result is allocated to the different characteristic time residence

  3. Transient two-phase two-component water-steam-air flow

    International Nuclear Information System (INIS)

    Kolev, N.I.

    1983-01-01

    A mathematical model of a transient one-dimensional two-phase flow consisting of water, steam, and air is described. In the general case, a system of four partial differential equations of hyperbolic type was derived. The expression obtained for the velocity of sound is in good agreement with the results of the experiment. There is also good agreement with existing theories for the limiting cases of a missing phase or component. A numerical example demonstrating the application of the theory is shown

  4. Fractional governing equations of transient groundwater flow in confined aquifers with multi-fractional dimensions in fractional time

    Science.gov (United States)

    Kavvas, M. Levent; Tu, Tongbi; Ercan, Ali; Polsinelli, James

    2017-10-01

    Using fractional calculus, a dimensionally consistent governing equation of transient, saturated groundwater flow in fractional time in a multi-fractional confined aquifer is developed. First, a dimensionally consistent continuity equation for transient saturated groundwater flow in fractional time and in a multi-fractional, multidimensional confined aquifer is developed. For the equation of water flux within a multi-fractional multidimensional confined aquifer, a dimensionally consistent equation is also developed. The governing equation of transient saturated groundwater flow in a multi-fractional, multidimensional confined aquifer in fractional time is then obtained by combining the fractional continuity and water flux equations. To illustrate the capability of the proposed governing equation of groundwater flow in a confined aquifer, a numerical application of the fractional governing equation to a confined aquifer groundwater flow problem was also performed.

  5. Study of transient and permanent flow in the event of natural convection in a confined environment

    International Nuclear Information System (INIS)

    Tenchine, Denis.

    1978-01-01

    This report deals with natural convection in a confined environment, in connection with the studies on the safety of nuclear reactors of the sodium cooled breeder type (possibilities of removing the residual power of the fuel by natural convection in the liquid sodium). These natural convection exchanges develop in a confined environment between various sodium volumes separated by metallic structures. The study covered a cavity heated by the roof or by the bottom and cooled laterally. The results are compared with those achieved along heating plates, vertical or horizontal, in an infinite medium and the effect of the thermal limit conditions are highlighted by comparison with the case of bottom heated and roof cooled cavities. Placed in a bidimensional geometry situation, with water as fluid, this leads to tackling the problems of similitude between water and sodium flows. A digital code has been developed in plane bidimensional geometry with a laminar and permanent flow. A description is given of the 'BIDIM' experimental rig as well as the measuring and display devices. A permanent flow study of the two previously mentioned configurations produces references for the analysis of transient flows, particularly in the case of the heating bottom (field of medium temperatures and medium exchange coefficient). The turbulence intensity and frequency distribution determinations of the temperature changes are given. Then the determinations of the temperature changes are given. Then the determinations in transient flow are dealt with in the case of the heating bottom. The cavity being initially cold, a power rise is initiated in the heating plates and the establishment and growth of natural convection and the change in the field of medium temperatures and exchange coefficient are studied [fr

  6. The Transient Aerodynamic Forces Effected by Trailing Edge Active Flow Control

    Science.gov (United States)

    Brzozowski, Dan; Culp, John; Glezer, Ari

    2012-11-01

    The transient aerodynamic forces effected by trailing edge flow control are investigated in wind tunnel experiments using a 2-DOF traverse which enables application of time-dependent external torque and forces by servo motors. The global aerodynamic forces and moments are regulated by controlling vorticity generation and accumulation near the surface using hybrid synthetic jet actuators. The time-histories of surface pressure and aerodynamic lift and pitching moment immediately following the application of flow control are measured using simultaneous pressure, force and velocity measurements that are taken phase-locked to the commanded actuation waveform. Circulation time history that is estimated from a PIV wake survey shows that the entire flow over the airfoil readjusts within about 1 . 5TCONV , which is about two orders of magnitude shorter than the characteristic time associated with the controlled maneuver of the wind tunnel model. This illustrates that flow-control actuation can be typically effected on time scales that are commensurate with the flow's convective time scale, and that the maneuver response is primarily limited by the inertia of the platform.

  7. PIV measurement of the complex and transient cross-flow over a circular cylinder

    International Nuclear Information System (INIS)

    Kuwabara, Joji; Someya, Satoshi; Okamoto, Koji

    2007-01-01

    This paper describe about measurement for the complex and transient cross-flow over a circular cylinder with the dynamic (time resolved) PIV (particle image velocimetry) techniques. The experiment was carried out water flow tunnel with a working section of 50x50 mm, at the Reynolds number 6.7 x 10 3 to 2.7 x 10 4 . This circular cylinder constructed with MEXFLON resin, the end of circular cylinder is rigidly supported and the other is free. The MEXFLON is fluorine resin; its refractive index is almost same as the water with high transparency. Very high speed water flow among the test section had been clearly visualized and captured by high speed camera. The fluctuations of the flow structure also are clearly obtained with high spatial and high temporal resolution, 512x512pixel with 10,000fps. It corresponds to set up number of thousands LDV array at the test section. Consequently, we found there are asynchronous vibration between parallel-ward and perpendicular-ward to main flow. (author)

  8. A computer program for transient incompressible fluid flow based on quadratic finite elements

    International Nuclear Information System (INIS)

    Laval, H.

    1981-01-01

    The computer code CONVEC is a general computer program designed for the solution of transient two-dimensional incompressible fluid flow problems. The solution procedure is based on the finite element method. The class of problems treated by the present version of CONVEC are those described by the time-dependent, two-dimensional (plane or axisymmetric) form of the Navier-Stokes equations. The flow field is assumed to be laminar and the fluid Newtonian and incompressible within the Boussinesq approximation. The present report is intended to provide a description of the input data necessary to access and execute the code. In the following sections, the basic dimensions and input data of CONVEC are described. Then a test problem is solved in order to illustrate the input and output of the code

  9. Numerical simulation of multi-dimensional two-phase transient flow across bundles

    International Nuclear Information System (INIS)

    Xu Liangwang; Jia Baoshan

    2012-01-01

    A multi-dimensional two-fluid model for two-phase flow across bundles is presented. The concept of porous media and distributed resistance are applied to derive the two-fluid Navier-Stokes equation of equivalent continuum, which is discretized with full implicit scheme on multi-dimensional staggered grid and solved with direct Strong Implicit Procedure (SIP). A numerical simulation of kettle reboiler experiment is implemented for model verification. Good agreement between the numerical results and experimental data is obtained, which proves that the suggested model is able to handle with two-phase instability numerically and suitable for the simulation of multi-dimensional two-phase transient flow across bundles. (authors)

  10. Chemical Reaction Effect on Transient Free Convective Flow past an Infinite Moving Vertical Cylinder

    Directory of Open Access Journals (Sweden)

    Ashish Paul

    2013-01-01

    Full Text Available An analysis is performed to study the heat and mass transfer on the flow past an infinite moving vertical cylinder, in the presence of first-order chemical reaction. The closed-form solutions of the dimensionless governing partial differential equations are obtained in terms of Bessel's functions and modified Bessel's functions by the Laplace transform technique. The transient velocity profiles, temperature profiles, and concentration profiles are studied for various sets of physical parameters, namely, the chemical reaction parameter, Prandtl number, Schmidt number, thermal Grashof number, mass Grashof number, and time. The skin friction, Nusselt number, and Sherwood number are also obtained and presented in graphs. It is observed that in presence of as well as increase in chemical reaction the flow velocity decreases. Also, in presence of destructive chemical reaction the concentration profile and Sherwood number tend to the steady state at large time.

  11. Numerical Modeling of Water Flow and Salt Transport in Bare Saline Soil Subjected to Transient Evaporation

    Science.gov (United States)

    Geng, X.; Boufadel, M.; Saleh, F. S.

    2014-12-01

    It has been found that evaporation over bare soil plays an important role in subsurface solute transport processes. A numerical study, based on a density-dependent variably saturated groundwater flow model MARUN, was conducted to investigate subsurface flow and salt transport in bare saline aquifers subjected to transient evaporation. The bulk aerodynamic formulation was adopted to simulate transient evaporation rate at ground surface. Subsurface flow pattern, moisture distribution, and salt migration were quantified. Key factors likely affecting this process, including saturated hydraulic conductivity, capillary drive, air humidity, and surrounding water supply, were examined. The results showed that evaporation induced an upward flow pattern, which led to a high saline plume formed beneath the evaporation zone. In absence of surrounding water supply, as the humidity between the ground surface and air tended to equilibrium, evaporation-induced density gradient generated pore water circulations around the plume edge and caused the salt to migrate downwards with "finger" shapes. It was found that capillary properties and atmospheric condition had significant impacts on subsurface moisture distribution and salt migration in response to the evaporation. Larger capillary fringe and/or lower air humidity would allow evaporation to extract more water from the ground. It would induce a larger and denser saline plume formed beneath the evaporation zone. The results also suggested that the presence of the surrounding water supply (represented as a constant water table herein) could provide a steady evaporation rate at the ground surface; meanwhile, in response to the evaporation, a hydraulic gradient was formed from the water supply boundary, which induced an inclined upper saline plume with greater density far from the supply boundary.

  12. Transcranial magnetic stimulation-induced global propagation of transient phase resetting associated with directional information flow

    Directory of Open Access Journals (Sweden)

    Masahiro eKawasaki

    2014-03-01

    Full Text Available Electroencephalogram (EEG phase synchronization analyses can reveal large-scale communication between distant brain areas. However, it is not possible to identify the directional information flow between distant areas using conventional phase synchronization analyses. In the present study, we applied transcranial magnetic stimulation (TMS to the occipital area in subjects who were resting with their eyes closed, and analyzed the spatial propagation of transient TMS-induced phase resetting by using the transfer entropy (TE, to quantify the causal and directional flow of information. The time-frequency EEG analysis indicated that the theta (5 Hz phase locking factor (PLF reached its highest value at the distant area (the motor area in this study, with a time lag that followed the peak of the transient PLF enhancements of the TMS-targeted area at the TMS onset. PPI (phase-preservation index analyses demonstrated significant phase resetting at the TMS-targeted area and distant area. Moreover, the TE from the TMS-targeted area to the distant area increased clearly during the delay that followed TMS onset. Interestingly, the time lags were almost coincident between the PLF and TE results (152 vs. 165 ms, which provides strong evidence that the emergence of the delayed PLF reflects the causal information flow. Such tendencies were observed only in the higher-intensity TMS condition, and not in the lower-intensity or sham TMS conditions. Thus, TMS may manipulate large-scale causal relationships between brain areas in an intensity-dependent manner. We demonstrated that single-pulse TMS modulated global phase dynamics and directional information flow among synchronized brain networks. Therefore, our results suggest that single-pulse TMS can manipulate both incoming and outgoing information in the TMS-targeted area associated with functional changes.

  13. Maximizing flow velocities in redox-magnetohydrodynamic microfluidics using the transient faradaic current.

    Science.gov (United States)

    Weston, Melissa C; Nash, Christena K; Homesley, Jerry J; Fritsch, Ingrid

    2012-11-06

    There is a need for a microfluidic pumping technique that is simple to fabricate, yet robust, compatible with a variety of solvents, and which has easily controlled fluid flow. Redox-magnetohydrodynamics (MHD) offers these advantages. However, the presence of high concentrations of redox species, important for inducing sufficient convection at low magnetic fields for hand-held devices, can limit the use of redox-MHD pumping for analytical applications. A new method for redox-MHD pumping is investigated that takes advantage of the large amplitude of the transient portion of the faradaic current response that occurs upon stepping the potential sufficiently past the standard electrode potential, E°, of the pumping redox species at an electrode. This approach increases the velocity of the fluid for a given redox concentration. An electronic switch was implemented between the potentiostat and electrochemical cell to alternately turn on and off different electrodes along the length of the flow path to maximize this transient electronic current and, as a result, the flow speed. Velocities were determined by tracking microbeads in a solution containing electroactive potassium ferrocyanide and potassium ferricyanide, and supporting electrolyte, potassium chloride, in the presence of a magnetic field. Fluid velocities with slight pulsation were obtained with the switch that were 70% faster than the smooth velocities without the switch. This indicates that redox species concentrations can be lowered by a similar amount to achieve a given speed, thereby diminishing interference of the redox species with detection of the analyte in applications of redox-MHD microfluidics for chemical analysis.

  14. Transient Fluid Flow Modeling in Fractured Aquifer of Sechahoon Iron Mine Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Mojtaba Darabi

    2016-06-01

    Full Text Available Considering the fact that a large volume of iron reserve in the Sechahoon Iron Mine in Yazd Province has located under the water table, it is necessary to conduct a comprehensive study on water flow within the pit and its surroundings. The conceptual model of the aquifer was created using surface and underground geological information compared with water table data of the area of interest. In the data preparation stages, in order to create the numerical model, Logan and Lufran tests were studied to determine the hydrodynamic coefficients of the layers, precipitation and evaporation were investigated, and fractures and faults of the region, as a medium for flow channels in the hard formation, were also studied. The model was created in a transient state between 2000 and 2014. To validate its results, the water table was measured 4 times in the last 4 months of 2014. Considering the complexities in the heterogeneous fractured aquifer of the study area, numerical modeling results for the basin in a transient state present 90 percent correlation with field studies. Having investigated the water balance in the region, the boundary condition of the model was determined as the input water from the eastern south and the runoff water in the western north of the region. Since the general trend of faults in the area is north-south, variation in the water table is slight on north-south and intense on the east-west direction. On the other hand, due to the fact that the maximum flow is along the faults and fractures, the water table contour lines in different locations over the region are closed.

  15. Combining geoelectrical and advanced lysimeter methods to characterize heterogeneous flow and transport under unsaturated transient conditions

    Science.gov (United States)

    Wehrer, M.; Skowronski, J.; Binley, A. M.; Slater, L. D.

    2013-12-01

    driven by textural heterogeneities. As a consequence, preferential transport of the conservative tracer also occurred. However, tracer displacement is subject not only to preferential flow but also to dilution, which complicates the interpretation of the imaging results by ERT. The novelty of our approach includes spatially and temporally highly resolved measurements under transient boundary conditions in combination with a multicompartment suction plate. Through systematic variation of boundary conditions we were able to overcome interpretation bias in the ERT data resulting from simultaneous changes of water content and pore fluid conductivity. We consider this an important step towards field applications of ERT for process identification and model parameterization.

  16. CORTES, Steady-State and Transient Heat Flow and Stress Analysis in Pipe Joints

    International Nuclear Information System (INIS)

    Gantayat, A. N.; Powell, G. H.; Textor, R. E.; Bass, B. R.; Bryson, J. W.; Moore, S. E.

    1996-01-01

    1 - Description of problem or function: CORTES is a package consisting of five finite element programs developed for the stress analysis of ANSI Bl6.9 tee joints. The five programs are: SA, the stress analysis program which analyzes pipe joints for the effects of internal pressure and arbitrary combinations of bending moment, torsional moment, axial force, and sheer force on the ends of the branch and run pipes. A limited temperature stress analysis capability is provided. EP, the elasto-plastic stress analysis program which analyzes pipe joints for the effects of internal pressure and arbitrary combinations of forces (including moments) and displacements including rotations imposed on the ends of the run and branch pipes. THFA, the transient heat flow analysis program which determines the time history of temperature variations in the pipe joints. The joint is assumed initially to be at a uniform temperature. Temperature changes are then specified at the inner surface, and a heat flow analysis is performed assuming a perfectly insulated outer surface. SHFA, the steady-state heat flow analysis program which determines the steady-state temperature distribution in pipe joints. Temperatures are specified on given cross-sections of the branch and run portions of the tee joint, and the temperature distribution throughout the remainder of the joint is calculated assuming the inner and outer surfaces are perfectly insulated. TSA, accepts as input, the output data from THFA or SHFA and performs the thermal stress analysis on the pipe joints. 2 - Method of solution: The joint is idealized as a system of 8-node hexahedral finite elements. A modified Zienkiewicz-Irons iso-parametric element which has superior bending properties compared with the unmodified iso-parametric element is used. The transient heat flow (THFA) problem is solved by a step-by-step integration procedure assuming linear variation of temperature with time within a step. 3 - Restrictions on the complexity of

  17. A system of hyperbolic differential equations for the description of a transient inhomogeneous equilibrium two-phase flow

    International Nuclear Information System (INIS)

    Kolev, N.I.

    1982-01-01

    In the case of small leaks the description of a two-phase flow can be based on a change of the equilibrium state. Because of separation effects to be expected, however, it is necessary to take the inhomogeneity of the flow into account. A model of a transient inhomogeneous equilibrium two-phase flow is presented, which allows to modify already existing computer codes, describing the homogeneous two-phase flow in complex networks with distributed parameters, in such a way that they can be used for describing the inhomogeneity of the two-phase flow without changing the structure of the codes. (author)

  18. Start-Up and Transient Flow Effects From the Molecular Weight Distribution

    Science.gov (United States)

    Borg, Tommi; Pääkkönen, Esko J.

    2008-07-01

    Start-up and transient shear-stress flows are modeled here using the recently generated constitutive model for linear viscoelasticity of polymers. The relation derived from control theory and the melt calibration procedure has been developed between the relaxation modulus, dynamic viscosity, and molecular-weight distribution (MWD). This study extends the start-up, and transient effects of linear viscoelasticity on stress and viscosity from the novel viewpoint of the classical Boltzmann superposition principle. The shear viscosity measurements of well-characterized classical low-density polyethylene (LDPE IUPAC A) with a known MWD were used to obtain time-dependent stress and viscosity transitions. The developed formulas model the start-up situation with an overshoot effect and shear-stress growth coefficient. Simulations were performed for relaxation modulus measurements at different shear histories defined by the effective viscosity. As an example of practical application, injection molding for producing a cellular-phone cover were modeled to obtain the pressure loss and orientation level for every element in finite element models, which predicted the shrinking and warping of the end products.

  19. Analysis of transient flow boiling: application of the method of characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Hancox, W.T. (Atomic Energy of Canada, Ltd., Manitoba); Mathers, W.G.; Kawa, D.

    1978-01-01

    An analysis, based on the method of characteristics, was deveoped for transient flow boiling; particular emphasis was placed on blowdown from subcooled liquid conditions. The governing equations are quasilinear partial differential equations of the hyperbolic type which are derived from the conservation laws assuming one-dimensional homogeneous thermal equilibrium flow. Using a wave tracing procedure, the solution is advanced at grid points in the spacetime plane which are the intersections of the characteristic curves. The contribution of the present paper is in the application of this technique, used extensively in gas dynamics, to flow boiling dynamics. Special procedures were developed to handle discontinuities and complex wave interactions which arise owing to phase changes. Wave diagrams obtained using the wave tracing technique are discussed and compared with experimental data. The more complex forms of the one-dimensional homogeneous conservation laws and required constitutive equations, which incorporate departures from thermal equilibrium are also presented. The extension of the method of characteristics to these systems of equations is discussed.

  20. Experimental investigation on the transient one phase flow through perforated plates

    International Nuclear Information System (INIS)

    Casadei, F.; Dalle Donne, M.

    1982-01-01

    The coolant flow across the perforated dip-plate during a HCDA in a LMFBR was simulated in a one-dimensional model. Several experiments with water as fluid and with various perforation ratios of the dip-plate and different initial heights of the fluid head over the dip-plate were run. The pressure drop across the dip-plate and the forces acting on the dip-plate and on the upper plug of the reactor vessel were measured in a wide range of the Reynolds and Strouhal numbers. The flow pattern downstreams the perforated plate was filmed with high-speed cameras. The resistance coefficients for the transient flow of the coolant through the perforated plate were obtained as a function of the acceleration. The forces acting on the upper plug and their time integral were compared with those acting on the dip-plate. Finally, using high-speed film pictures the formation of fluid jets downstream the dip-plate was investigated

  1. Evaluation of Available Transfer Capability Using Transient Stability Constrained Line Flows

    Science.gov (United States)

    Uzoechi, Lazarus Okechukwu; Mahajan, Satish M.

    2014-01-01

    This paper presents a methodology to evaluate transient stability constrained available transfer capability (ATC). A linear and fast line flow-based (LFB) method was adopted to optimize the ATC values. This enabled the direct determination of the system source-sink locations. This paper formulated different market transactions considering bilateral and multilateral impacts in the stability constrained ATC. The proposed method was demonstrated on the WECC 9-bus and IEEE 39-bus systems. The critical energy performance index (CEPI) enabled the direct identification of candidates for contingency screening based on ranking. This index helped to reduce the list of credible contingencies for ATC evaluation and, therefore, the computation time. The results of the proposed ATC method are consistent with the literature and can be deployed for fast assessment of the impact of transactions in an electric power system.

  2. Safety aspects of forced flow cooldown transients in modular high temperature gas-cooled reactors

    International Nuclear Information System (INIS)

    Kroeger, P.G.

    1992-01-01

    During some of the design basis accidents in Modular High Temperature Gas Cooled Reactors (MHTGRs) the main Heat Transport System (HTS) and the Shutdown Cooling System (SCS), are assumed to have failed. Decay heat is then removed by the passive Reactor Cavity Cooling System (RCCS) only. If either forced flow cooling system becomes available during such a transient, its restart could significantly reduce the down-time. This paper uses the THATCH code to examine whether such restart, during a period of elevated core temperatures, can be accomplished within safe limits for fuel and metal component temperatures. If the reactor is scrammed, either system can apparently be restarted at any time, without exceeding any safe limits. However, under unscrammed conditions a restart of forced cooling can lead to recriticality, with fuel and metal temperatures significantly exceeding the safety limits

  3. Busy period analysis, rare events and transient behavior in fluid flow models

    Directory of Open Access Journals (Sweden)

    Søren Asmussen

    1994-01-01

    Full Text Available We consider a process {(Jt,Vt}t≥0 on E×[0,∞, such that {Jt} is a Markov process with finite state space E, and {Vt} has a linear drift ri on intervals where Jt=i and reflection at 0. Such a process arises as a fluid flow model of current interest in telecommunications engineering for the purpose of modeling ATM technology. We compute the mean of the busy period and related first passage times, show that the probability of buffer overflow within a busy cycle is approximately exponential, and give conditioned limit theorems for the busy cycle with implications for quick simulation. Further, various inequalities and approximations for transient behavior are given. Also explicit expressions for the Laplace transform of the busy period are found. Mathematically, the key tool is first passage probabilities and exponential change of measure for Markov additive processes.

  4. MaMiCo: Transient multi-instance molecular-continuum flow simulation on supercomputers

    Science.gov (United States)

    Neumann, Philipp; Bian, Xin

    2017-11-01

    We present extensions of the macro-micro-coupling tool MaMiCo, which was designed to couple continuum fluid dynamics solvers with discrete particle dynamics. To enable local extraction of smooth flow field quantities especially on rather short time scales, sampling over an ensemble of molecular dynamics simulations is introduced. We provide details on these extensions including the transient coupling algorithm, open boundary forcing, and multi-instance sampling. Furthermore, we validate the coupling in Couette flow using different particle simulation software packages and particle models, i.e. molecular dynamics and dissipative particle dynamics. Finally, we demonstrate the parallel scalability of the molecular-continuum simulations by using up to 65 536 compute cores of the supercomputer Shaheen II located at KAUST. Program Files doi:http://dx.doi.org/10.17632/w7rgdrhb85.1 Licensing provisions: BSD 3-clause Programming language: C, C++ External routines/libraries: For compiling: SCons, MPI (optional) Subprograms used: ESPResSo, LAMMPS, ls1 mardyn, waLBerla For installation procedures of the MaMiCo interfaces, see the README files in the respective code directories located in coupling/interface/impl. Journal reference of previous version: P. Neumann, H. Flohr, R. Arora, P. Jarmatz, N. Tchipev, H.-J. Bungartz. MaMiCo: Software design for parallel molecular-continuum flow simulations, Computer Physics Communications 200: 324-335, 2016 Does the new version supersede the previous version?: Yes. The functionality of the previous version is completely retained in the new version. Nature of problem: Coupled molecular-continuum simulation for multi-resolution fluid dynamics: parts of the domain are resolved by molecular dynamics or another particle-based solver whereas large parts are covered by a mesh-based CFD solver, e.g. a lattice Boltzmann automaton. Solution method: We couple existing MD and CFD solvers via MaMiCo (macro-micro coupling tool). Data exchange and

  5. Transient behavior of natural circulation for boiling two-phase flow, 2

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Chiang, Jing-Hsien; Mori, Michitugu.

    1991-01-01

    In this set of experiments, natural circulation in boiling two-phase flow has been investigated for power transients, simulating the start-up process in a natural circulation BWR. This was done in order to understand the underlying mechanism of thermo-hydraulic instability which may appear during a start-up. In this paper, geysering is dealt with especially and the driving mechanism is clarified by investigating the stability related to effects of inlet velocity, subcooling, temperature in an outlet plenum and non-heated length between heated section and the outlet plenum. Furthermore, by considering these results and the operational experience in the Dodewaard reactor, recommendations on how the thermo-hydraulic instabilities can be prevented from occurring are proposed concerning a reactor configuration and start-up procedure for natural circulation BWRs. (author)

  6. Two-dimensional computational modeling of high-speed transient flow in gun tunnel

    Science.gov (United States)

    Mohsen, A. M.; Yusoff, M. Z.; Hasini, H.; Al-Falahi, A.

    2018-03-01

    In this work, an axisymmetric numerical model was developed to investigate the transient flow inside a 7-meter-long free piston gun tunnel. The numerical solution of the gun tunnel was carried out using the commercial solver Fluent. The governing equations of mass, momentum, and energy were discretized using the finite volume method. The dynamic zone of the piston was modeled as a rigid body, and its motion was coupled with the hydrodynamic forces from the flow solution based on the six-degree-of-freedom solver. A comparison of the numerical data with the theoretical calculations and experimental measurements of a ground-based gun tunnel facility showed good agreement. The effects of parameters such as working gases and initial pressure ratio on the test conditions in the facility were examined. The pressure ratio ranged from 10 to 50, and gas combinations of air-air, helium-air, air-nitrogen, and air-CO2 were used. The results showed that steady nozzle reservoir conditions can be maintained for a longer duration when the initial conditions across the diaphragm are adjusted. It was also found that the gas combination of helium-air yielded the highest shock wave strength and speed, but a longer test time was achieved in the test section when using the CO2 test gas.

  7. Numerical Simulation of Transient Multiphase Flow in a Five-Strand Bloom Tundish during Ladle Change

    Directory of Open Access Journals (Sweden)

    Hua Zhang

    2018-02-01

    Full Text Available The steel-slag-air multiphase flow in a bloom tundish with five strands during the transient casting of the ladle change was simulated using the Volume of Fluid (VOF model, and the formation mechanisms of macro-inclusions and the behavior of the steel-slag-air interface during the filling process were investigated. Water model experiments were conducted to validate the multiphase model. The results showed that the numerical results of slag entrapment behavior and the exposed area of steel are basically consistent with the experimental results. The flow of molten steel in the tundish is weak except for the region around the stopper rods at the end of the emptying process. Strong fluctuations in liquid level were formed during the filling process, showing two wave crests in front of and behind the shroud in the impact zone, which intensified with the increase in filling time and then declined gradually. Entrapment phenomena and exposure of liquid steel could not be observed before the filling stage. While the entrapped slag droplets mostly float up and can be removed within 40 s during the filling process, the remainder enters the casting zone through the baffle. The maximum exposed area of molten steel is 252 cm2 when the filling time is 4.0 s.

  8. Visualizing the transient electroosmotic flow and measuring the zeta potential of microchannels with a micro-PIV technique.

    Science.gov (United States)

    Yan, Deguang; Nguyen, Nam-Trung; Yang, Chun; Huang, Xiaoyang

    2006-01-14

    We have demonstrated a transient micro particle image velocimetry (micro-PIV) technique to measure the temporal development of electroosmotic flow in microchannels. Synchronization of different trigger signals for the laser, the CCD camera, and the high-voltage switch makes this measurement possible with a conventional micro-PIV setup. Using the transient micro-PIV technique, we have further proposed a method on the basis of inertial decoupling between the particle electrophoretic motion and the fluid electroosmotic flow to determine the electrophoretic component in the particle velocity and the zeta potential of the channel wall. It is shown that using the measured zeta potentials, the theoretical predictions agree well with the transient response of the electroosmotic velocities measured in this work.

  9. Flow field effect transistors with polarisable interface for EOF tunable microfluidic separation devices.

    Science.gov (United States)

    Plecis, A; Tazid, J; Pallandre, A; Martinhon, P; Deslouis, C; Chen, Y; Haghiri-Gosnet, A M

    2010-05-21

    A method is proposed to control the zeta potential in microchannels using electrically polarisable interfaces in direct contact with the electrolyte. The approach is based on the use of conducting layers exhibiting minimal electrochemical reactions with aqueous electrolytes but a large potential window (typically from -2 V to +2 V) enabling tuning their zeta potential without detrimental faradic reactions. SiC, Al and CN(x) interfaces were deposited on glass surfaces and then integrated into glass-PDMS-glass devices. The effect of the zeta potential control was monitored by measuring the electro-osmotic flow using a microfluidic Wheatstone Bridge. The experimental results are in good agreement with theoretical predictions based on a one dimensional modeling. The electro-osmotic flow control obtained at high pH values suggests that it should be possible to use such devices as Polarisable Interface Flow-Field Effect Transistors (PI-FFETs) to overcome the difficulties met with conventional metal-isolator-electrolyte systems (MIE-FFETs) for electrokinetic separation applications.

  10. A Unique Facility for the Study of Transient Single-Species Annular Flow Near Total Film Evaporation

    Science.gov (United States)

    Morse, Roman; Kris Dressler Team; Brian Fehring Team; James Doherty Team; Simon Livingston-Jha Team; Arganthal Berson Team

    2017-11-01

    A new facility was built for the study of transient effects in two-phase vertical annular flow near dry out. The facility uses two water/glycol loops and two 10 kW heat pumps to vaporize and condense the working fluid in the annular flow experiment, R-245fa. The annular flow is created by mixing a steady flow of slightly superheated vapor refrigerant with a steady flow of subcooled liquid refrigerant in a junction specifically designed to minimize droplet entrainment. In a separate tank, saturated refrigerant is heated to generate additional vapor to add to the steady state vapor to create transient conditions. Trains of vapor pulses can be created with controlled amplitude and frequency. The effects of the transient flow on dry out are characterized in a test section 110 diameters downstream of the vapor-liquid mixing junction. The test section consists of 14 transparent windows, which are coated with conductive fluorine-doped tin oxide. Current is passed through each of the windows, providing up to 1.4 kW of additional heating power to create film evaporation, or dry out conditions. The transparent windows also allow for simultaneous laser-based film-thickness and wall-temperature measurements.

  11. 2D transient granular flows over obstacles: experimental and numerical work

    Science.gov (United States)

    Juez, Carmelo; Caviedes-Voullième, Daniel; Murillo, Javier; García-Navarro, Pilar

    2016-04-01

    Landslides are an ubiquitous natural hazard, and therefore human infrastructure and settlements are often at risk in mountainous regions. In order to better understand and predict landslides, systematic studies of the phenomena need to be undertaken. In particular, computational tools which allow for analysis of field problems require to be thoroughly tested, calibrated and validated under controlled conditions. And to do so, it is necessary for such controlled experiments to be fully characterized in the same terms as the numerical model requires. This work presents an experimental study of dry granular flow over a rough bed with topography which resembles a mountain valley. It has an upper region with a very high slope. The geometry of the bed describes a fourth order polynomial curve, with a low point with zero slope, and afterwards a short region with adverse slope. Obstacles are present in the lower regions which are used as model geometries of human structures. The experiments consisted of a sudden release a mass of sand on the upper region, and allowing it to flow downslope. Furthermore, it has been frequent in previous studies to measure final states of the granular mass at rest, but seldom has transient data being provided, and never for the entire field. In this work we present transient measurements of the moving granular surfaces, obtained with a consumer-grade RGB-D sensor. The sensor, developed for the videogame industry, allows to measure the moving surface of the sand, thus obtaining elevation fields. The experimental results are very consistent and repeatable. The measured surfaces clearly show the distinctive features of the granular flow around the obstacles and allow to qualitatively describe the different flow patterns. More importantly, the quantitative description of the granular surface allows for benchmarking and calibration of predictive numerical models, key in scaling the small-scale experimental knowledge into the field. In addition, as

  12. Safety analysis of loss of flow transients in a typical research reactor by RELAP5/MOD3.3

    International Nuclear Information System (INIS)

    Di Maro, B.; Pierro, F.; Adorni, M.; Bousbia Salah, A.; D'Auria, F.

    2003-01-01

    The main aim of the following study is to assess the RELAP5/MOD3.3 code capability in simulating transient dynamic behaviour in nuclear research reactors. For this purpose typical loss of flow transient in a representative MTR (Metal Test Reactor) fuel type Research Reactor is considered. The transient herein considered is a sudden pump trip followed by the opening of a safety valve in order to allow passive decay heat removal by natural convection. During such transient the coolant flow decay, originally downward, leads to a flow reversal and the cooling process of the core passes from forced, mixed and finally to natural circulation. This fact makes it suitable for evaluating the new features of RELAP5 to simulate such specific operating conditions. The instantaneous reactor power is derived through the point kinetic calculation, both protected and unprotected cases are considered (with and without Scram). The results obtained from this analysis were also compared with previous results obtained by old version RELAP5/MOD2 code. (author)

  13. Simulating water-quality trends in public-supply wells in transient flow systems

    Science.gov (United States)

    Starn, J. Jeffrey; Green, Christopher T.; Hinkle, Stephen R.; Bagtzoglou, Amvrossios C.; Stolp, Bernard J.

    2014-01-01

    Models need not be complex to be useful. An existing groundwater-flow model of Salt Lake Valley, Utah, was adapted for use with convolution-based advective particle tracking to explain broad spatial trends in dissolved solids. This model supports the hypothesis that water produced from wells is increasingly younger with higher proportions of surface sources as pumping changes in the basin over time. At individual wells, however, predicting specific water-quality changes remains challenging. The influence of pumping-induced transient groundwater flow on changes in mean age and source areas is significant. Mean age and source areas were mapped across the model domain to extend the results from observation wells to the entire aquifer to see where changes in concentrations of dissolved solids are expected to occur. The timing of these changes depends on accurate estimates of groundwater velocity. Calibration to tritium concentrations was used to estimate effective porosity and improve correlation between source area changes, age changes, and measured dissolved solids trends. Uncertainty in the model is due in part to spatial and temporal variations in tracer inputs, estimated tracer transport parameters, and in pumping stresses at sampling points. For tracers such as tritium, the presence of two-limbed input curves can be problematic because a single concentration can be associated with multiple disparate travel times. These shortcomings can be ameliorated by adding hydrologic and geologic detail to the model and by adding additional calibration data. However, the Salt Lake Valley model is useful even without such small-scale detail.

  14. Measurement of the combined heat and water-vapour flow through clothing under transient conditions

    Science.gov (United States)

    Farnworth, B.; Nordli, B.

    1982-03-01

    A sweating hot plate for the study of combined heat and water-vapor flow through clothing under Transient conditions is described. The results are in good agreement with the mathematical model reported in a previous paper for several model clothing systems. The heat loss through wool clothing was found to be smaller than that through similar polyester clothing during periods of sweating and larger during subsequent periods of drying, because of the effects of absorption of water vapor by hygroscopic materials. A comparison was made of the heat and vapor transmission of the clothing systems by incorporating a vapor-impermeable fabric or the waterproof but vapor-permeable fabric Gore-TEx. Liquid water was observed to condence on the inner surface of both fabrics during periods of sweating but the Gore-TEx dried within a few minutes of the end of the sweating period. Gore-TEx was found to be vapor permeable even at temperatures below 0 degrees C when frost was forming on its inner surface.

  15. SOLA-VOF: a solution algorithm for transient fluid flow with multiple free boundaries

    International Nuclear Information System (INIS)

    Nichols, B.D.; Hirt, C.W.; Hotchkiss, R.S.

    1980-08-01

    In this report a simple, but powerful, computer program is presented for the solution of two-dimensional transient fluid flow with free boundaries. The SOLA-VOF program, which is based on the concept of a fractional volume of fluid (VOF), is more flexible and efficient than other methods for treating arbitrary free boundaries. SOLA-VOF has a variety of user options that provide capabilities for a wide range of applications. Its basic mode of operation is for single fluid calculations having multiple free surfaces. However, SOLA-VOF can also be used for calculations involving two fluids separated by a sharp interface. In either case, the fluids may be treated as incompressible or as having limited compressibility. Surface tension forces with wall adhesion are permitted in both cases. Internal obstacles may be defined by blocking out any desired combination of cells in the mesh, which is composed of rectangular cells of variable size. SOLA-VOF is an easy-to-use program. Its logical parts are isolated in separate subroutines, and numerous special features have been included to simplify its operation, such as an automatic time-step control, a flexible mesh generator, extensive output capabilities, a variety of optional boundary conditions, and instructive internal documentation

  16. SPLOSH III. A code for calculating reactivity and flow transients in CSGHWR

    International Nuclear Information System (INIS)

    Halsall, M.J.; Course, A.F.; Sidell, J.

    1979-09-01

    SPLOSH is a time dependent, one dimensional, finite difference (in time and space) coupled neutron kinetics and thermal hydraulics code for studying pressurised faults and control transients in water reactor systems. An axial single channel model with equally spaced mesh intervals is used to represent the neutronics of the reactor core. A radial finite difference model is used for heat conduction through the fuel pin, gas gap and can. Appropriate convective, boiling or post-dryout heat transfer correlations are used at the can-coolant interface. The hydraulics model includes the important features of the SGHWR primary loop including 'slave' channels in parallel with the 'mean' channel. Standard mass, energy and momentum equations are solved explicitly. Circuit features modelled include pumps, spray cooling and the SGHWR steam drum. Perturbations to almost any feature of the circuit model may be specified by the user although blowdown calculations resulting in critical or reversed flows are not permitted. Automatic reactor trips may be defined and the ensuing actions of moderator dumping and rod firing can be specified. (UK)

  17. Transient flow conditions change how we should think about WHPA delineation: a joint frequency and probability analysis

    Science.gov (United States)

    Rodriguez Pretelin (1), Abelardo; Nowak (1), Wolfgang

    2017-04-01

    Well head protection areas (WHPAs) are frequently used as safety measures for drinking water wells, preventing them from being polluted by restricting land use activities in their proximities. Two sources of uncertainty are involved during delineation: 1) uncertainty in aquifer parameters and 2) time-varying groundwater flow scenarios and their own inherent uncertainties. The former has been studied by Enzenhoefer et al (2012 [1] and 2014 [2]) as probabilistic risk version of WHPA delineation. The latter is frequently neglected and replaced by steady-state assumptions; thereby ignoring time-variant flow conditions triggered either by anthropogenic causes or climatic conditions. In this study we analyze the influence of transient flow considerations in WHPA delineation, following annual seasonality behavior; with transiency represented by four transient conditions: (I) regional groundwater flow direction, (II) strength of the regional hydraulic gradient, (III) natural recharge to the groundwater and (IV) pumping rate. Addressing WHPA delineation in transient flow scenarios is computationally expensive. Thus, we develop an efficient method using a dynamic superposition of steady-state flow solutions coupled with a reversed formulation of advective-dispersive transport based on a Lagrangian particle tracking with continuous injection. This analysis results in a time-frequency map of pixel-wise membership to the well catchment. Additional to transient flow conditions, we recognize two sources of uncertainty, inexact knowledge of transient drivers and parameters. The uncertainties are accommodated through Monte Carlo simulation. With the help of a global sensitivity analysis, we investigate the impact of transiency in WHPA solutions. In particular, we evaluate: (1) Among all considered transients, which ones are the most influential. (2) How influential in WHPA delineation is the transience-related uncertainty compared to aquifer parameter uncertainty. Literature [1] R

  18. Time Resolved Particle Image Velocimetry Techniques with Continuous Wave Laser and their Application to Transient Flows

    Science.gov (United States)

    Esposito, Chiara

    freestream velocity of 11m/sec. In the second part of the present work, an application of the technique on transient flow with moving boundaries was attempted. This involved the investigation of the unusually high unsteady aerodynamic forces generated on a flat panel (actuator) during its impulsive deployment against the incoming turbulent boundary layer flow. The actuator is embedded in the wall and it's fully deployed when it reaches 90 degree angle. Also, experiments at different deployment speeds (1 to 20 rad/sec) and different Reynolds numbers (23,000 and 68,200) were carried out to investigate their effects on the force generation. In particular three different sets of experiments were carried out. The first one aimed at directly measuring the aerodynamic forces with the means of a force balance. In these experiments, significantly higher aerodynamic forces are seen compared to the steady state case for the actuator at full deployment. These higher aerodynamic forces increase with the increasing values of the Strouhal number. The other two sets were carried out to understand the flow dynamics during the deployment. In these sets, flow visualization and TR-PIV experiments were carried out to investigate the flow structure around the actuator. It is has been observed that at the early stages of the deployment a tip vortex is developed. This vortex carries significant strength as seen by the vorticity magnitude during the deployment. This vortex is separated from the actuator during the early stages of the deployment. However, it stays in the vicinity of the wake of the actuator during most of the deployment period, while a large increase in its strength is observed. It is believed that this strong vorticity field of the tip vortex structure is initially generated on the surface of the actuator during the early part of deployment, while the actuator is moving with high acceleration. This vortical structure, which is not observed in the steady state case, is seen to be

  19. Calculation of sample problems related to two-phase flow blowdown transients in pressure relief piping of a PWR pressurizer

    International Nuclear Information System (INIS)

    Shin, Y.W.; Wiedermann, A.H.

    1984-02-01

    A method was published, based on the integral method of characteristics, by which the junction and boundary conditions needed in computation of a flow in a piping network can be accurately formulated. The method for the junction and boundary conditions formulation together with the two-step Lax-Wendroff scheme are used in a computer program; the program in turn, is used here in calculating sample problems related to the blowdown transient of a two-phase flow in the piping network downstream of a PWR pressurizer. Independent, nearly exact analytical solutions also are obtained for the sample problems. Comparison of the results obtained by the hybrid numerical technique with the analytical solutions showed generally good agreement. The good numerical accuracy shown by the results of our scheme suggest that the hybrid numerical technique is suitable for both benchmark and design calculations of PWR pressurizer blowdown transients

  20. Preliminary analysis of selected gas dynamic problems. [space shuttle main engine main combustion transients and IUS nozzle flow

    Science.gov (United States)

    Prozan, R. J.; Farmer, R. C.

    1985-01-01

    The VAST computer code was used to analyze SSME main combustion chamber start-up transients and the IUS flow field for a damaged nozzle was investigated to better understand the gas dynamic considerations involved in vehicle problems, the effect of start transients on the nozzle flow field for the SSME, and the possibility that a damaged nozzle could account for the acceleration anomaly noted on IUS burn. The results obtained were compared with a method of characteristics prediction. Pressure solutions from both codes were in very good agreement and the Mach number solution on the nozzle centerline deviates substantially for the high expansions for the SSME. Since this deviation was unexpected, the phenomenon is being further examined.

  1. Finite element method for transient flow of homogeneous gas-liquid mixtures in rigid and quasi-rigid pipelines

    International Nuclear Information System (INIS)

    Haj Kacem, Yassine; Hadj-Taieb, Ezzedine

    2017-01-01

    A numerical solution based on the finite element method is presented to describe wave propagations in the transient flow of homogeneous gas-liquid mixtures in rigid and quasi-rigid pipes. The rigid model is deduced by neglecting the liquid compressibility and the pipe wall elasticity against the gas compressibility. But, these two parameters are taken into consideration in the quasi-rigid model. The effect of fluid compressibility on the pressure waves of transient flow is then analyzed and confronted to the pipe wall elasticity. To validate the reliability of the model presented herein, the numerical results are compared with those obtained by the finite difference method and experiment. The results show that the pressure wave propagation is significantly influenced by gas-fluid mass ratio and pipe wall elasticity. (authors)

  2. Cerebral blood flow SPET in transient global amnesia with automated ROI analysis by 3DSRT

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Ryo [Division of Nuclear Medicine, Nishi-Kobe Medical Center, Kohjidai 5-7-1, 651-2273, Nishi-ku, Kobe-City, Hyogo (Japan); Matsuda, Hiroshi [Department of Radiology, National Center Hospital for Mental, Nervous and Muscular Disorders, National Center of Neurology and Psychiatry, Tokyo (Japan); Yoshioka, Katsunori [Daiichi Radioisotope Laboratories, Ltd., Tokyo (Japan); Yonekura, Yoshiharu [Biomedical Imaging Research Center, University of Fukui, Fukui (Japan)

    2004-04-01

    The aim of this study was to determine the areas involved in episodes of transient global amnesia (TGA) by calculation of cerebral blood flow (CBF) using 3DSRT, fully automated ROI analysis software which we recently developed. Technetium-99m l,l-ethyl cysteinate dimer single-photon emission tomography ({sup 99m}Tc-ECD SPET) was performed during and after TGA attacks on eight patients (four men and four women; mean study interval, 34 days). The SPET images were anatomically standardized using SPM99 followed by quantification of 318 constant ROIs, grouped into 12 segments (callosomarginal, precentral, central, parietal, angular, temporal, posterior cerebral, pericallosal, lenticular nucleus, thalamus, hippocampus and cerebellum), in each hemisphere to calculate segmental CBF (sCBF) as the area-weighted mean value for each of the respective 12 segments based on the regional CBF in each ROI. Correlation of the intra- and post-episodic sCBF of each of the 12 segments of the eight patients was estimated by scatter-plot graphical analysis and Pearson's correlation test with Fisher's Z-transformation. For the control, {sup 99m}Tc-ECD SPET was performed on eight subjects (three men and five women) and repeated within 1 month; the correlation between the first and second sCBF values of each of the 12 segments was evaluated in the same way as for patients with TGA. Excellent reproducibility between the two sCBF values was found in all 12 segments of the control subjects. However, a significant correlation between intra- and post-episodic sCBF was not shown in the thalamus or angular segments of TGA patients. The present study was preliminary, but at least suggested that thalamus and angular regions are closely involved in the symptoms of TGA. (orig.)

  3. Cerebral blood flow SPET in transient global amnesia with automated ROI analysis by 3DSRT

    International Nuclear Information System (INIS)

    Takeuchi, Ryo; Matsuda, Hiroshi; Yoshioka, Katsunori; Yonekura, Yoshiharu

    2004-01-01

    The aim of this study was to determine the areas involved in episodes of transient global amnesia (TGA) by calculation of cerebral blood flow (CBF) using 3DSRT, fully automated ROI analysis software which we recently developed. Technetium-99m l,l-ethyl cysteinate dimer single-photon emission tomography ( 99m Tc-ECD SPET) was performed during and after TGA attacks on eight patients (four men and four women; mean study interval, 34 days). The SPET images were anatomically standardized using SPM99 followed by quantification of 318 constant ROIs, grouped into 12 segments (callosomarginal, precentral, central, parietal, angular, temporal, posterior cerebral, pericallosal, lenticular nucleus, thalamus, hippocampus and cerebellum), in each hemisphere to calculate segmental CBF (sCBF) as the area-weighted mean value for each of the respective 12 segments based on the regional CBF in each ROI. Correlation of the intra- and post-episodic sCBF of each of the 12 segments of the eight patients was estimated by scatter-plot graphical analysis and Pearson's correlation test with Fisher's Z-transformation. For the control, 99m Tc-ECD SPET was performed on eight subjects (three men and five women) and repeated within 1 month; the correlation between the first and second sCBF values of each of the 12 segments was evaluated in the same way as for patients with TGA. Excellent reproducibility between the two sCBF values was found in all 12 segments of the control subjects. However, a significant correlation between intra- and post-episodic sCBF was not shown in the thalamus or angular segments of TGA patients. The present study was preliminary, but at least suggested that thalamus and angular regions are closely involved in the symptoms of TGA. (orig.)

  4. User's guide to HEATRAN: a computer program for three-dimensional transient fluid-flow and heat-transfer analysis

    International Nuclear Information System (INIS)

    Wong, C.N.C.; Cheng, S.K.; Todreas, N.E.

    1982-01-01

    This report provides the HEATRAN user with programming and input information. HEATRAN is a computer program which is written to analyze the transient three dimensional single phase incompressible fluid flow and heat transfer problem. In this report, the programming information is given first. This information includes details concerning the code and structure. The description of the required input variables is presented next. Following the input description, the sample problems are described and HEATRAN's results are presented

  5. Evaluating the environmental consequences of groundwater contamination. IV. Obtaining and utilizing contaminant arrival distributions in transient flow systems

    International Nuclear Information System (INIS)

    Nelson, R.W.

    1978-01-01

    The versatility of the new contaminant arrival distributions for determining environmental consequences of subsurface pollution problems is demonstrated through application to a transient flow system. Though some of the four phases of the hydrologic evaluations are more complicated because of the time dependence of the flow and input contaminant concentrations, the arrival distributions still effectively summarize the data required to determine the environmental implications. These arrival distributions yield two graphs or tabular sets of data giving the consequences of the subsurface pollution problems in a simple and direct form. 4 refs

  6. Transient Flows in a Pipe System with Pump Shut-Down and the Simultaneous Closing of a Spherical Valve

    Science.gov (United States)

    Zhang, Zh.

    2016-11-01

    Because of the limited value of the wave propagation speed in water the propagation of a pressure surge in transient flows can be tracked in the time series. This enables both the pressure head and the flow velocity in pipe flows to be determined as a function of both the coordinate along the pipe and the time. The propagation of the pressure surge includes both wave transmission and reflection. The latter occurs where the flow section is changed. The wave tracking method has been demonstrated as highly accurate and subsequently was applied to much more complex hydraulic systems, in which the pump is shut off and the spherical valve is simultaneously progressively closed. A combined four-quadrant characteristic of the pump and a spherical valve has been worked out, with which the computational procedure for the transient flow in the complex system could be significantly simplified. It has been demonstrated that not only the pressure surge in the hydraulic system but also the rotational speed of the pump could be satisfactorily computed. The computational algorithm has been demonstrated as quite simple, so that all calculations could be performed simply by means of the Microsoft Excel module.

  7. Analysis of transient and hysteresis behavior of cross-flow heat exchangers under variable fluid mass flow rate for data center cooling applications

    International Nuclear Information System (INIS)

    Gao, Tianyi; Murray, Bruce; Sammakia, Bahgat

    2015-01-01

    Effective thermal management of data centers is an important aspect of reducing the energy required for the reliable operation of data processing and communications equipment. Liquid and hybrid (air/liquid) cooling approaches are becoming more widely used in today's large and complex data center facilities. Examples of these approaches include rear door heat exchangers, in-row and overhead coolers and direct liquid cooled servers. Heat exchangers are primary components of liquid and hybrid cooling systems, and the effectiveness of a heat exchanger strongly influences the thermal performance of a cooling system. Characterizing and modeling the dynamic behavior of heat exchangers is important for the design of cooling systems, especially for control strategies to improve energy efficiency. In this study, a dynamic thermal model is solved numerically in order to predict the transient response of an unmixed–unmixed crossflow heat exchanger, of the type that is widely used in data center cooling equipment. The transient response to step and ramp changes in the mass flow rate of both the hot and cold fluid is investigated. Five model parameters are varied over specific ranges to characterize the transient performance. The parameter range investigated is based on available heat exchanger data. The thermal response to the magnitude, time period and initial and final conditions of the transient input functions is studied in detail. Also, the hysteresis associated with the fluid mass flow rate variation is investigated. The modeling results and performance data are used to analyze specific dynamic performance of heat exchangers used in practical data center cooling applications. - Highlights: • The transient performance of a crossflow heat exchanger was modeled and studied. • This study provides design information for data center thermal management. • The time constant metric was used to study the impacts of many variable inputs. • The hysteresis behavior

  8. On the use of hot-sphere anemometers in a highly transient flow in a double-skin facade

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Kalyanova, Olena; Hyldgård, Carl-Erik

    2007-01-01

    measured by the anemometer. Temperature compensation is the working principle of anemometers. The ability to compensate for different temperatures when exposed to solar radiation is investigated in a controlled environment using a powerful lamp as a radiant heat source. In the double-skin façade, both...... from the measurement of air velocity in the occupied zone. The velocity is higher and the flow is more transient, the anemometer is subjected to high loads of direct solar radiation and wide temperature ranges and, finally, the direction of the flow is important. The flow in the double-skin façade......Hot-sphere anemometers are widely used for measurement of air velocity in the occupied zone. In this paper, the ability of hot-sphere anemometers to measure transient flow in a double-skin façade is investigated. When hot-spheres are used in a double-skin façade, the conditions are very different...

  9. On the Use of Hot-Sphere Anemometers in a Highly Transient Flow in a Double-Skin Facade

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Kalyanova, Olena; Hyldgård, Carl-Erik

    2007-01-01

    Hot-sphere anemometers are widely used for measurement of air velocity in the occupied zone. In this paper, the ability of hot-sphere anemometers to measure transient flow in a double-skin façade is investigated. When hot-spheres are used in a double-skin façade, the conditions are very different...... from the measurement of air velocity in the occupied zone. The velocity is higher and the flow is more transient, the anemometer is subjected to high loads of direct solar radiation and wide temperature ranges and, finally, the direction of the flow is important. The flow in the double-skin façade...... measured by the anemometer. Temperature compensation is the working principle of anemometers. The ability to compensate for different temperatures when exposed to solar radiation is investigated in a controlled environment using a powerful lamp as a radiant heat source. In the double-skin façade, both...

  10. Measurement of transient two-phase flow velocity using statistical signal analysis of impedance probe signals

    International Nuclear Information System (INIS)

    Leavell, W.H.; Mullens, J.A.

    1981-01-01

    A computational algorithm has been developed to measure transient, phase-interface velocity in two-phase, steam-water systems. The algorithm will be used to measure the transient velocity of steam-water mixture during simulated PWR reflood experiments. By utilizing signals produced by two, spatially separated impedance probes immersed in a two-phase mixture, the algorithm computes the average transit time of mixture fluctuations moving between the two probes. This transit time is computed by first, measuring the phase shift between the two probe signals after transformation to the frequency domain and then computing the phase shift slope by a weighted least-squares fitting technique. Our algorithm, which has been tested with both simulated and real data, is able to accurately track velocity transients as fast as 4 m/s/s

  11. Effects of thermal stratification on transient free convective flow of a ...

    Indian Academy of Sciences (India)

    2016-09-22

    Sep 22, 2016 ... as well as average skin friction and the rate of heat transfer of nanofluids are discussed and represented graphically. The results are found to be in good agreement with the existing results in literature. Keywords. Nanofluid; thermal stratification; transient; isothermal vertical plate. PACS Nos 44.20.+b; 47; 44.

  12. Influence of transient flow in the formation of condensate and in the calculation of steam line

    International Nuclear Information System (INIS)

    Bazzo, E.

    1989-01-01

    The piping design is analyzed in unsteady-state conditions, with the main goal of minimizing operational costs and initial investments of a plant. All heat losses are calculated by applying the control volume method. The results confirm the applicability of the method and show that the influence of the transient regime on the condensation rate and economical insulation thickness must be considered. (author)

  13. Effects of thermal stratification on transient free convective flow of a ...

    Indian Academy of Sciences (India)

    An analysis of thermal stratification in a transient free convection of nanofluids past an isothermal vertical plate is performed. Nanofluids containing nanoparticles of aluminium oxide, copper, titanium oxide and silver having volume fraction of the nanoparticles less than or equal to 0.04 with water as the base fluid are ...

  14. Estimation of the quantification uncertainty from flow injection and liquid chromatography transient signals in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Laborda, Francisco; Medrano, Jesus; Castillo, Juan R.

    2004-01-01

    The quality of the quantitative results obtained from transient signals in high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and flow injection-inductively coupled plasma mass spectrometry (FI-ICPMS) was investigated under multielement conditions. Quantification methods were based on multiple-point calibration by simple and weighted linear regression, and double-point calibration (measurement of the baseline and one standard). An uncertainty model, which includes the main sources of uncertainty from FI-ICPMS and HPLC-ICPMS (signal measurement, sample flow rate and injection volume), was developed to estimate peak area uncertainties and statistical weights used in weighted linear regression. The behaviour of the ICPMS instrument was characterized in order to be considered in the model, concluding that the instrument works as a concentration detector when it is used to monitorize transient signals from flow injection or chromatographic separations. Proper quantification by the three calibration methods was achieved when compared to reference materials, although the double-point calibration allowed to obtain results of the same quality as the multiple-point calibration, shortening the calibration time. Relative expanded uncertainties ranged from 10-20% for concentrations around the LOQ to 5% for concentrations higher than 100 times the LOQ

  15. Transient cavitating vortical flows around a hydrofoil using k-ω partially averaged Navier-Stokes model

    Science.gov (United States)

    Luo, Xianwu; Huang, Renfang; Ji, Bin

    2016-01-01

    For accurate simulations of wall-bounded turbulent cavitating flows, the present paper proposed a partially averaged Navier-Stokes (PANS) method derived from the k-ω turbulence model. Transient cavitating vortical flows around a NACA66 hydrofoil were simulated by using the k-ω PANS model with various filter parameters (fk = 0.2, 0.5 and 1, while fω = 1/fk) and a mass transfer cavitation model based on the Rayleigh-Plesset equation. Compared with the available experimental data, the k-ω PANS model with fk = 0.2 can accurately reproduce the cavitation evolution with more complicated structures due to the reduction in the predicted eddy viscosity. Further analyses, using the vorticity transport equation, indicate that the transition of cavitation structure from two dimension to three dimension is associated with strong vortex-cavitation interaction, where vortex stretching and dilation may play a major role. Therefore, the k-ω PANS model with the filter parameter of fk = 0.2 is an effective method to numerically predict the transient cavitating vortical flows around hydrofoils. The results obtained in this paper are helpful to provide a physical insight into the mechanisms of cavitation shedding dynamics.

  16. PIV Measurement of Transient 3-D (Liquid and Gas Phases) Flow Structures Created by a Spreading Flame over 1-Propanol

    Science.gov (United States)

    Hassan, M. I.; Kuwana, K.; Saito, K.

    2001-01-01

    In the past, we measured three-D flow structure in the liquid and gas phases that were created by a spreading flame over liquid fuels. In that effort, we employed several different techniques including our original laser sheet particle tracking (LSPT) technique, which is capable of measuring transient 2-D flow structures. Recently we obtained a state-of-the-art integrated particle image velocimetry (IPIV), whose function is similar to LSPT, but it has an integrated data recording and processing system. To evaluate the accuracy of our IPIV system, we conducted a series of flame spread tests using the same experimental apparatus that we used in our previous flame spread studies and obtained a series of 2-D flow profiles corresponding to our previous LSPT measurements. We confirmed that both LSPT and IPIV techniques produced similar data, but IPIV data contains more detailed flow structures than LSPT data. Here we present some of newly obtained IPIV flow structure data, and discuss the role of gravity in the flame-induced flow structures. Note that the application of IPIV to our flame spread problems is not straightforward, and it required several preliminary tests for its accuracy including this IPIV comparison to LSPT.

  17. Soil pipe flow tracer experiments: 2. Application of a transient storage zone model

    Science.gov (United States)

    Soil pipes, defined here as discrete preferential flow paths generally parallel to the slope, are important subsurface flow pathways that play a role in many soil erosion phenomena. However, limited research has been performed on quantifying and characterizing their flow and transport characteristic...

  18. Experimental data report for transient flow calibration facility tests IIIA101, IIIA102, IIIA201, and IIIA202

    International Nuclear Information System (INIS)

    Wambach, J.L.

    1980-01-01

    Thermal-hydraulic response data are presented for the transient performance tests of an ECC pitot tube rake (IIIA201, IIIA202) and both an ECC pitot tube rake and modular drag disc-turbine transducer (DTT) rake (IIIA101, IIIA102). The tests were conducted in a system which provided full scale simulation of the pressure vessel and intact loop cold leg piping of the Loss of Fluid Test Facility (LOFT). A load cell system was used to provide a reference mass flow rate measurement

  19. Modular High-Temperature Gas-Cooled Reactor short term thermal response to flow and reactivity transients

    Energy Technology Data Exchange (ETDEWEB)

    Cleveland, J.C.

    1988-01-01

    The analyses reported here have been conducted at the Oak Ridge National Laboratory (ORNL) for the US Nuclear Regulatory Commission's (NRC's) Division of Regulatory Applications of the Office of Nuclear Regulatory Research. The short-term thermal response of the Modular High-Temperature Gas-Cooled Reactor (MHTGR) is analyzed for a range of flow and reactivity transients. These include loss of forced circulation (LOFC) without scram, moisture ingress, spurious withdrawal of a control rod group, hypothetical large and rapid positive reactivity insertion, and a rapid core cooling event. The coupled heat transfer-neutron kinetics model is also described.

  20. Modular high-temperature gas-cooled reactor short-term thermal response to flow and reactivity transients

    Energy Technology Data Exchange (ETDEWEB)

    Cleveland, J.C. (Oak Ridge National Lab., TN (United States))

    1993-02-01

    The research reported here has been conducted at the Oak Ridge National Laboratory for the Nuclear Regulatory Commission's Division of Regulatory Applications of the Office of Nuclear Regulatory Research. The short-term thermal response of the Modular High-Temperature Gas-Cooled Reactor (MHTGR) is analyzed for a range of flow and reactivity transients. These transients include loss of forced circulation without scram, spurious withdrawal of a control rod group, moisture ingress, control rod and control rod group ejections, and a rapid core cooling event. For each event analyzed, an event description, a discussion of the analysis approach and assumptions, and results are presented. When possible, results of these analyses are compared with those presented by the designers in the MHTGR Preliminary Safety Information Document and in the MHTGR Probabilistic Risk Assessment. The importance of inherent safety features is illustrated, and conclusions are presented regarding the safety performance of the MHTGR. Recommendations are made for a more in-depth examination of MHTGR response for some of the analyzed transients. The coupled heat transfer-neutron kinetics model is described in detail in Appendix A.

  1. Modular high-temperature gas-cooled reactor short-term thermal response to flow and reactivity transients

    International Nuclear Information System (INIS)

    Cleveland, J.C.

    1993-02-01

    The research reported here has been conducted at the Oak Ridge National Laboratory for the Nuclear Regulatory Commission's Division of Regulatory Applications of the Office of Nuclear Regulatory Research. The short-term thermal response of the Modular High-Temperature Gas-Cooled Reactor (MHTGR) is analyzed for a range of flow and reactivity transients. These transients include loss of forced circulation without scram, spurious withdrawal of a control rod group, moisture ingress, control rod and control rod group ejections, and a rapid core cooling event. For each event analyzed, an event description, a discussion of the analysis approach and assumptions, and results are presented. When possible, results of these analyses are compared with those presented by the designers in the MHTGR Preliminary Safety Information Document and in the MHTGR Probabilistic Risk Assessment. The importance of inherent safety features is illustrated, and conclusions are presented regarding the safety performance of the MHTGR. Recommendations are made for a more in-depth examination of MHTGR response for some of the analyzed transients. The coupled heat transfer-neutron kinetics model is described in detail in Appendix A

  2. Transient radial flow to a well in an unconfined aquifer. Part 1, An evaluation of some conceptual methods

    Energy Technology Data Exchange (ETDEWEB)

    Narasimhan, T.N.; Zhu, Ming

    1991-08-01

    The analytic solutions of Boulton (1954) and Neuman (1972) for transient flow to a well in an unconfined aquifer are based on the assumption that the role of the unsaturated zone can be adequately accounted for by restricting attention to the release of water from the zone through which the water table moves. Both researchers mathematically treat this released water as a time-dependent source term. The differences between the models of Boulton and Neuman are that the former neglects vertical components of flow in the aquifer, but allows for an exponential process for the release of water as a function of time, whereas the latter assumes instantaneous release from storage, but accounts for vertical components of flow. Given this set of assumptions, we examine the applicability of these two methods using a general purpose numerical model through a process of verification extension and comparison. The issues addressed include: the role of well-bore storage in masking intermediate-time behavior, combined effects of exponential release as well as vertical flow, logic for vertical averaging of drawdowns, and the sensitivity of system response to the magnitude of specific yield. The issue of how good the assumptions of Boulton and Neuman are in the context of the general theory of unsaturated flow is addressed in part 2 of this two-part series of reports.

  3. COMPARE: a computer program for the transient calculation of a system of volumes connected by flowing vents

    International Nuclear Information System (INIS)

    Gido, R.G.; Grimes, C.I.; Lawton, R.G.; Kudrick, J.A.

    1976-09-01

    A description is given of the COMPARE computer program developed for performing transient subcompartment pressure response analyses of nuclear power plants. The subcompartments are represented as volumes (less than or equal to 100) which are connected by junctions (less than or equal to 200) and may have blowdown (less than or equal to 5 sets). The volume thermodynamics and flow equations are for a homogeneous mixture, assumed to be in thermodynamic equilibrium consisting of any one, or any combination, of the following: (a) steam, (b) two-phase water, and (c) any three perfect gases such as air, helium, etc. Flow between volumes is based on (a) the Moody equation, with an arbitrary multiplier, when the flow is critical, (b) compressible, polytropic, orifice flow of an ideal gas-like mixture when the flow is subcritical, and (c) an incompressible subelement method when inertia effects exist. A quasi-static explicit numerical solution technique is used. The program requires 40,000 words on the LASL CDC-7600 and 124,000 10 bytes on an IBM 360/370 computer. A two-volume, one-junction problem requires 0.002 s per time step on the CDC-7600 and 0.012 s on the IBM 360/370

  4. Modelling transient pipe flow with cavitation and frequency dependent friction. Part II. Friction and numerical-experimental validation

    Directory of Open Access Journals (Sweden)

    Kamil Urbanowicz

    2015-09-01

    Full Text Available Modelling of time-depended hydraulic friction is not an easy issue. As numerous studies have shown, wall shear stress in the pipe can be determined as a sum of the quasi-steady and time-dependent expressions. Time-depended expression is an convolution integral of the local acceleration of the liquid and a weighting function. The weighting function, in general, makes allowance for relation of historic velocity changes and unsteady component of wall shear stress. The original weighting function has usually a very complicated structure, and what is more it makes impossible to do an efficient simulation of dynamical runs. In this paper, in order to enable efficient calculation of unsteady component wall shear stress, new weighting functions are presented as a sum of exponential components. To aim this goal in case of turbulent flow, the scaling procedure proposed by Vitkovsky et al. is used. This method makes very easy the estimation of any new turbulent weighting function. Presented approximated weighting functions are compared with the original counterparts, known from literature in case of laminar and turbulent flows. Using the previously discussed models of cavitation flow CSM, CSMG, CSMA, and the BCM with implemented effective weighting function a series of simulation studies has been made, which showed that the introduced changes in models of unsteady flow with cavitation greatly improve the degree of simulation fit in comparison with experimental results.[b]Keywords[/b]: numerical fluid mechanics, transient flow, cavitation, frequency-dependent friction losses, pipeline, waterhammer

  5. Impact of anisotropic slip on transient three dimensional MHD flow of ferrofluid over an inclined radiate stretching surface

    Directory of Open Access Journals (Sweden)

    A.M. Rashad

    2017-04-01

    Full Text Available The present study explores the impact of anistropic slip on transient three dimensional MHD flow of Cobalt-kerosene ferrofluid over an inclined radiate stretching surface. The governing partial differential equations for this study are solved by the Thomas algorithm with finite-difference type. The impacts of several significant parameters on flow and heat transfer characteristics are exhibited graphically. The conclusion is revealed that the local Nusselt number is significantly promoted due to influence of thermal radiation whereas diminished with elevating the solid volume fraction, magnet parameter and slip factors. Further, the skin friction coefficients visualizes a considerable enhancement with boosting the magnet and radiation parameters, but a prominent reduction is recorded by elevating the solid volume fraction and slip factors.

  6. Capturing 2D transient surface data of granular flows against obstacles with an RGB-D sensor

    Science.gov (United States)

    Caviedes-Voullieme, Daniel; Juez, Carmelo; Murillo, Javier; Garcia-Navarro, Pilar

    2014-05-01

    Landslides are an ubiquitous natural hazard, and therefore human infrastructure and settlements are often at risk in mountainous regions. In order to better understand and predict landslides, systematic studies of the phenomena need to be undertaken. In particular, computational tools which allow for analysis of field problems require to be thoroughly tested, calibrated and validated under controlled conditions. And to do so, it is necessary for such controlled experiments to be fully characterized in the same terms as the numerical model requires. This work presents an experimental study of dry granular flow over a rough bed with topography which resembles a mountain valley. It has an upper region with a very high slope. The geometry of the bed describes a fourth order polynomial curve, with a low point with zero slope, and afterwards a short region with adverse slope. Obstacles are present in the lower regions which are used as model geometries of human structures. The experiments consisted of a sudden release a mass of sand on the upper region, and allowing it to flow downslope. Furthermore, it has been frequent in previous studies to measure final states of the granular mass at rest, but seldom has transient data being provided, and never for the entire field. In this work we present transient measurements of the moving granular surfaces, obtained with a consumer-grade RGB-D sensor. The sensor, developed for the videogame industry, allows to measure the moving surface of the sand, thus obtaining elevation fields. The experimental results are very consistent and repeatable. The measured surfaces clearly show the distinctive features of the granular flow around the obstacles and allow to qualitatively describe the different flow patterns. More importantly, the quantitative description of the granular surface allows for benchmarking and calibration of predictive numerical models, key in scaling the small-scale experimental knowledge into the field.

  7. Numerical investigation of transient transport and deposition of microparticles under unsteady inspiratory flow in human upper airways.

    Science.gov (United States)

    Naseri, Arash; Shaghaghian, Sana; Abouali, Omid; Ahmadi, Goodarz

    2017-10-01

    In the present study, unsteady airflow patterns and particle deposition in healthy human upper airways were simulated. A realistic 3-D computational model of the upper airways including the vestibule to the end of the trachea was developed using a series of CT scan images of a healthy human. Unsteady simulations of the inhaled and exhaled airflow fields in the upper airway passages were performed by solving the Navier-Stokes and continuity equations for low breathing rates corresponding to low and moderate activities. The Lagrangian trajectory analysis approach was utilized to investigate the transient particle transport and deposition under cyclic breathing condition. Particles were released uniformly at the nostrils' entrance during the inhalation phase, and the total and regional depositions for various micro-particle sizes were evaluated. The transient particle deposition fractions for various regions of the human upper airways were compared with those obtained from the equivalent steady flow condition. The presented results revealed that the equivalent constant airflow simulation can approximately predict the total particle deposition during cyclic breathing in human upper airways. While the trends of steady and unsteady model predictions for local deposition were similar, there were noticeable differences in the predicted amount of deposition. In addition, it was shown that a steady simulation cannot properly predict some critical parameters, such as the penetration fraction. Finally, the presented results showed that using a detached nasal cavity (commonly used in earlier studies) for evaluation of total deposition fraction of particles in the nasal cavity was reasonably accurate for the steady flow simulations. However, in transient simulation for predicting the deposition fraction in a specific region, such as the nasal cavity, using the full airway system geometry becomes necessary. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Identifying the contribution of capillary, film and vapour flow by inverse simulation of transient evaporation experiments

    Science.gov (United States)

    Iden, Sascha; Diamantopoulos, Efstathios; Durner, Wolfgang

    2017-04-01

    Evaporation from bare soil is an important component of the water cycle and the surface energy balance in arid and semi-arid regions. Modeling soil water movement in dry soil and predicting the evaporation fluxes to the atmosphere still face considerable challenges. Flow simulations rely on a proper conceptual model for water flow and an adequate parameterization of soil hydraulic properties. While the inclusion of vapor flow into variably-saturated flow models has become more widespread recently, the parametrization of the unsaturated hydraulic conductivity function in dry soil is often still based on sparse literature data from the past which do not extend into the dry range. Another shortcoming is that standard models of hydraulic conductivity do not account for water flow in incompletely-filled pores, i.e. film and corner flow. The objective of this study was to identify soil hydraulic properties by inverse modeling, with a particular focus on the medium to dry moisture range. We conducted evaporation experiments on large soil columns under laboratory conditions and used an extended instrumentation, consisting of minitensiometers and relative humidity sensors, to measure the pressure head over a wide range from saturation to -100 MPa. Evaporation rate and column-averaged water content were measured gravimetrically. The resulting data were evaluated by inverse modeling using the isothermal Richards equation as process model. Our results clearly demonstrate that classic models of soil hydraulic conductivity which are based on the assumption that water flows exclusively in water-filled capillaries, cannot describe the observed time series of pressure head and relative humidity. An adequate description of the observations was only possible by accounting for isothermal vapor flow and an additional flow of liquid water. The physical cause of the latter could be film and corner flow as proposed before based on a theoretical analysis of water flow in angular porous

  9. Effect of transient change in strain rate on plastic flow behaviour of ...

    Indian Academy of Sciences (India)

    Steels; stress–strain measurement; plastic flow; mechanical properties; metallurgy. ... Haasen plot revealed that the mobile dislocation density remained almost invariant at the juncture where there was a sudden increase in stress with a change in strain rate and the plastic flow was solely dependent on the velocity of mobile ...

  10. Blood viscoelasticity measurement using steady and transient flow controls of blood in a microfluidic analogue of Wheastone-bridge channel

    Science.gov (United States)

    Jun Kang, Yang; Lee, Sang-Joon

    2013-01-01

    Accurate measurement of blood viscoelasticity including viscosity and elasticity is essential in estimating blood flows in arteries, arterials, and capillaries and in investigating sub-lethal damage of RBCs. Furthermore, the blood viscoelasticity could be clinically used as key indices in monitoring patients with cardiovascular diseases. In this study, we propose a new method to simultaneously measure the viscosity and elasticity of blood by simply controlling the steady and transient blood flows in a microfluidic analogue of Wheastone-bridge channel, without fully integrated sensors and labelling operations. The microfluidic device is designed to have two inlets and outlets, two side channels, and one bridge channel connecting the two side channels. Blood and PBS solution are simultaneously delivered into the microfluidic device as test fluid and reference fluid, respectively. Using a fluidic-circuit model for the microfluidic device, the analytical formula is derived by applying the linear viscoelasticity model for rheological representation of blood. First, in the steady blood flow, the relationship between the viscosity of blood and that of PBS solution (μBlood/μPBS) is obtained by monitoring the reverse flows in the bridge channel at a specific flow-rate rate (QPBSSS/QBloodL). Next, in the transient blood flow, a sudden increase in the blood flow-rate induces the transient behaviors of the blood flow in the bridge channel. Here, the elasticity (or characteristic time) of blood can be quantitatively measured by analyzing the dynamic movement of blood in the bridge channel. The regression formula (ABlood (t) = Aα + Aβ exp [−(t − t0)/λBlood]) is selected based on the pressure difference (ΔP = PA − PB) at each junction (A, B) of both side channels. The characteristic time of blood (λBlood) is measured by analyzing the area (ABlood) filled with blood in the bridge channel by selecting an appropriate detection window in the

  11. Characteristics and stability analyses of transient one-dimensional two-phase flow equations and their finite difference approximations

    International Nuclear Information System (INIS)

    Lyczkowski, R.W.; Gidaspow, D.; Solbrig, C.W.; Hughes, E.D.

    1975-01-01

    Equation systems describing one-dimensional, transient, two-phase flow with separate continuity, momentum, and energy equations for each phase are classified by use of the method of characteristics. Little attempt is made to justify the physics of these equations. Many of the equation systems possess complex-valued characteristics and hence, according to well-known mathematical theorems, are not well-posed as initial-value problems (IVPs). Real-valued characteristics are necessary but not sufficient to insure well-posedness. In the absence of lower order source or sink terms (potential type flows), which can affect the well-posedness of IVPs, the complex characteristics associated with these two-phase flow equations imply unbounded exponential growth for disturbances of all wavelengths. Analytical and numerical examples show that the ill-posedness of IVPs for the two-phase flow partial differential equations which possess complex characteristics produce unstable numerical schemes. These unstable numerical schemes can produce apparently stable and even accurate results if the growth rate resulting from the complex characteristics remains small throughout the time span of the numerical experiment or if sufficient numerical damping is present for the increment size used. Other examples show that clearly nonphysical numerical instabilities resulting from the complex characteristics can be produced. These latter types of numerical instabilities are shown to be removed by the addition of physically motivated differential terms which eliminate the complex characteristics. (auth)

  12. A Mathematical Model for the Analysis of the Pressure Transient Response of Fluid Flow in Fractal Reservoir

    Directory of Open Access Journals (Sweden)

    Jin-Zhou Zhao

    2015-01-01

    Full Text Available This study uses similar construction method of solution (SCMS to solve mathematical models of fluid spherical flow in a fractal reservoir which can avoid the complicated mathematical deduction. The models are presented in three kinds of outer boundary conditions (infinite, constant pressure, and closed. The influence of wellbore storage effect, skin factor, and variable flow rate production is also involved in the inner boundary conditions. The analytical solutions are constructed in the Laplace space and presented in a pattern with one continued fraction—the similar structure of solution. The pattern can bring convenience to well test analysis programming. The mathematical beauty of fractal is that the infinite complexity is formed with relatively simple equations. So the relation of reservoir parameters (wellbore storage effect, the skin factor, fractal dimension, and conductivity index, the formation pressure, and the wellbore pressure can be learnt easily. Type curves of the wellbore pressure and pressure derivative are plotted and analyzed in real domain using the Stehfest numerical invention algorithm. The SCMS and type curves can interpret intuitively transient pressure response of fractal spherical flow reservoir. The results obtained in this study have both theoretical and practical significance in evaluating fluid flow in such a fractal reservoir and embody the convenience of the SCMS.

  13. Transient magneto-peristaltic flow of couple stress biofluids: a magneto-hydro-dynamical study on digestive transport phenomena.

    Science.gov (United States)

    Tripathi, Dharmendra; Anwar Bég, O

    2013-11-01

    Magnetic fields are increasingly being utilized in endoscopy and gastric transport control. In this regard, the present study investigates the influence of a transverse magnetic field in the transient peristaltic rheological transport. An electrically-conducting couple stress non-Newtonian model is employed to accurately simulate physiological fluids in peristaltic flow through a sinusoidally contracting channel of finite length. This model is designed for computing the intra-bolus oesophageal and intestinal pressures during the movement of food bolus in the digestive system under magneto-hydro-dynamic effects. Long wavelength and low Reynolds number approximations have been employed to reduce the governing equations from nonlinear to linear form, this being a valid approach for creeping flows which characterizes physiological dynamics. Analytical approximate solutions for axial velocity, transverse velocity, pressure gradient, local wall shear stress and volumetric flow rate are obtained for the non-dimensional conservation equations subject to appropriate boundary conditions. The effects of couple stress parameter and transverse magnetic field on the velocity profile, pressure distribution, local wall shear stress and the averaged flow rate are discussed with the aid of computational results. The comparative study of non-integral and integral number of waves propagating along the finite length channel is also presented. Magnetic field and non-Newtonian properties are found to strongly influence peristaltic transport. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. An efficient numerical approach for transient simulation of multiphase flow behavior in centrifuges

    OpenAIRE

    Hammerich, Simon; Nirschl, Hermann

    2016-01-01

    The separation process of particles and liquids in centrifuge is a widely used operation in industry. In spite of the long term usage of centrifuges, the knowledge for a detailed characterization of the interaction of the macroscopic processes due the separation is lacking. Reason for this is the complex multiphase flow and the sediment built-up within the machines. The sediment shape influences the flow behavior. The shape is dependent of the rheological behavior of the sediment. Computation...

  15. Affinity flow fractionation of cells via transient interactions with asymmetric molecular patterns

    Science.gov (United States)

    Bose, Suman; Singh, Rishi; Hanewich-Hollatz, Mikhail; Shen, Chong; Lee, Chia-Hua; Dorfman, David M.; Karp, Jeffrey M.; Karnik, Rohit

    2013-07-01

    Flow fractionation of cells using physical fields to achieve lateral displacement finds wide applications, but its extension to surface molecule-specific separation requires labeling. Here we demonstrate affinity flow fractionation (AFF) where weak, short-range interactions with asymmetric molecular patterns laterally displace cells in a continuous, label-free process. We show that AFF can directly draw neutrophils out of a continuously flowing stream of blood with an unprecedented 400,000-fold depletion of red blood cells, with the sorted cells being highly viable, unactivated, and functionally intact. The lack of background erythrocytes enabled the use of AFF for direct enumeration of neutrophils by a downstream detector, which could distinguish the activation state of neutrophils in blood. The compatibility of AFF with capillary microfluidics and its ability to directly separate cells with high purity and minimal sample preparation will facilitate the design of simple and portable devices for point-of-care diagnostics and quick, cost-effective laboratory analysis.

  16. Affinity flow fractionation of cells via transient interactions with asymmetric molecular patterns.

    Science.gov (United States)

    Bose, Suman; Singh, Rishi; Hanewich-Hollatz, Mikhail; Shen, Chong; Lee, Chia-Hua; Dorfman, David M; Karp, Jeffrey M; Karnik, Rohit

    2013-01-01

    Flow fractionation of cells using physical fields to achieve lateral displacement finds wide applications, but its extension to surface molecule-specific separation requires labeling. Here we demonstrate affinity flow fractionation (AFF) where weak, short-range interactions with asymmetric molecular patterns laterally displace cells in a continuous, label-free process. We show that AFF can directly draw neutrophils out of a continuously flowing stream of blood with an unprecedented 400,000-fold depletion of red blood cells, with the sorted cells being highly viable, unactivated, and functionally intact. The lack of background erythrocytes enabled the use of AFF for direct enumeration of neutrophils by a downstream detector, which could distinguish the activation state of neutrophils in blood. The compatibility of AFF with capillary microfluidics and its ability to directly separate cells with high purity and minimal sample preparation will facilitate the design of simple and portable devices for point-of-care diagnostics and quick, cost-effective laboratory analysis.

  17. Transient core characteristics of small molten salt reactor coupling problem between heat transfer/flow and nuclear fission reaction

    International Nuclear Information System (INIS)

    Yamamoto, Takahisa; Mitachi, Koshi

    2004-01-01

    This paper performed the transient core analysis of a small Molten Salt Reactor (MSR). The emphasis is that the numerical model employed in this paper takes into account the interaction among fuel salt flow, nuclear reaction and heat transfer. The model consists of two group diffusion equations for fast and thermal neutron fluexs, balance equations for six-group delayed neutron precursors and energy conservation equations for fuel salt and graphite moderator. The results of transient analysis are that (1) fission reaction (heat generation) rate significantly increases soon after step reactivity insertion, e.g., the peak of fission reaction rate achieves about 2.7 times larger than the rated power 350 MW when the reactivity of 0.15% Δk/k 0 is inserted to the rated state, and (2) the self-control performance of the small MSR effectively works under the step reactivity insertion of 0.56% Δk/k 0 , putting the fission reaction rate back on the rated state. (author)

  18. Molecularly based criteria for shear banding in transient flow of entangled polymeric fluids.

    Science.gov (United States)

    Mohagheghi, Mouge; Khomami, Bamin

    2016-06-01

    Dissipative particle dynamics simulations of polymeric melts in a start-up of shear flow as a function of ramp time to its steady state value is studied. Herein, we report the molecular findings showing the effect of ramp time on the formation of shear banded structures and chain relaxation behavior. Specifically, it is shown that shear banding emerges at a rapid start-up; however, homogeneous shear prevails when the deformation rate ramp time is sufficiently slow. This finding is in full consistency with prior continuum level linear stability analysis of shear banding in start-up of shear flows as well as experimental observations of entangled DNA and polymer solutions. Further, it has been revealed that the ratio of the longest chain orientation relaxation time to that of the time for the imposed deformation rate to reach its steady state value plays a central role in determining whether local strain inhomogeneities that lead to the formation of shear banded flow structures are created. In addition, we have shown that the gradient of the number of entanglements along the velocity gradient direction should reach a critical value for the creation of localized strain inhomogeneity. Moreover, the relation between the local process leading to shear banded flows and the relaxation mechanism of the chain is discussed. Overall, a molecular picture for the interrelation between the longest chain orientation and stress relaxation time, local inhomogeneities, and shear banding has been proposed and corroborated with extensive analysis.

  19. Preliminary Study on Mass Flow Rate in Passive Cooling Experimental Simulation During Transient Using NC-Queen Apparatus

    Directory of Open Access Journals (Sweden)

    M. Juarsa

    2014-12-01

    Full Text Available The research related to thermal management has been significantly inreased, especially for NPP safety. The use of passive cooling systems both during the accident and operation become reliable in the advanced reactor safety systems. Therefore it should be enhanced through experimental studies to investigate heat transfer phenomenon of the heat decay in transient cooling condition.An investigation has been performed through experiment using an NC-Queen apparatusconstructed with rectangular loop. Piping were consisting of tubes of SS316L with diameter, length, and width of 3/4 inch, 2.7 m, and 0.5 m respectively. The height between heater and cooler was 1.4 m. The experiment used initial water temperature at 70oC, 80oC, and 90oC in heater area. Transient temperature was used as experimental data to calculate water mass flow rate. The results showed that the temperature in heater area and cooler area were decreasing of about 90.6% and 95.7% at initial temperatur of 80oC, and of about 71.1% and 59.4% at initial temperature of 70oC. Those results were at higher initial temperature of 90oC compared with the initial temperature of 90oC. The average of water mass flow rate increased 81.03% from initial temperatur of 70oC. It was shown that the averages of removed heat in every second from water due to heat loss and cooler,were 3.51 watts, 5.06 watts and 6.85 watts respectively. The initial condition of heat stored in the water was quite different, but to the cooler heat removal capacity and heat loss was almost the same.

  20. Manual for operation of the multipurpose thermalhydraulic test facility TOPFLOW (Transient Two Phase Flow Test Facility); Betriebshandbuch fuer die Mehrzweck-Thermohydraulikversuchsanlage TOPFLOW

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, M.; Carl, H.; Schuetz, H.; Pietruske, H.; Lenk, S. [SAAS Systemanalyse und Automatisierungsservice GmbH, Possendorf (Germany)

    2004-07-01

    The Forschungszentrum Rossendorf (FZR) e. V. is constructing a new large-scale test facility, TOPFLOW, for thermalhydraulic single effect tests. The acronym stands for transient two phase flow test facility. It will mainly be used for the investigation of generic and applied steady state and transient two phase flow phenomena and the development and validation of models of computational fluid dynamic (CFD) codes. The manual of the test facility must always be available for the staff in the control room and is restricted condition during operation of personnel and also reconstruction of the facility. (orig./GL)

  1. K-FIX(3D), Transient 2 Phase Flow Hydrodynamic, X-Y-Z and Cylindrical Geometry, Eulerian Method

    International Nuclear Information System (INIS)

    Rivard, W.C.; Torrey, MD.

    1982-01-01

    1 - Description of problem or function: This package consists of two programs K-FIX(3D,FLX) which extend the transient, two-dimensional, two fluid program K-FIX (NESC Abstract 727) to perform three- dimensional calculations. The transient dynamics of three- dimensional, two-phase flow with interfacial exchange are calculated at all flow speeds. Each phase is described in terms of its own density, velocity, and temperature. The application is to flow in the annulus between two cylinders where the inner cylinder moves periodically perpendicular to its axis. K-FIX(3D) is easily adaptable to a variety of two phase flow problems while K-FIX(3D,FLX) combines KFIX(3D), the three- dimensional version of the KFIX code, with the three-dimensional, elastic shell code FLX for application to a very specific class of problems. KFIX(3D,FLX) was developed specifically to calculate the coupled fluid structure dynamics of a light water reactor core support barrel under accident conditions. Motion may be induced by blowdown, prescribed displacement, or seismic action. 2 - Method of solution: In the K-FIX(3D), the six field equations for the two phases couple through mass, momentum, and energy exchange. The equations are solved using an Eulerian finite-difference technique that implicitly couples the rates of phase transitions, momentum, and energy exchange to determination of the pressure, density and velocity fields. The implicit solution is accomplished iteratively without linearizing the equations, thus eliminating the need for numerous derivative terms. With the three-dimensional K-FIX code calculations in Cartesian and cylindrical geometries can be performed. Obstacles built from the computing cells can be specified within the computing volume. In cylindrical geometry, calculations can be performed in the full 360 degrees or any angular segment. To enhance computing efficiency a new cell indexing scheme has been introduced, and computing time is reduced further by deletion of

  2. First-Principles Approach to Transient Heat Flow in Quantum Systems

    Science.gov (United States)

    Walczak, Kamil; Yerkes, Kirk; Nanoscale Physics Division Team; Thermal Management Center Collaboration

    2015-03-01

    We examine heat transfer via quantum advection modes (coherently correlated quantum states) between two thermal baths of different temperatures mediated by quantum system with discrete spectrum of accessible energy levels. Nanoscale transport is treated within the first-principles method by including the superposed wave functions into the quantum expression for heat flux. Our results show the specific modifications of heat transport characteristics due to the dynamics of quantum systems under consideration. Such dynamics is captured by non-steady-state solutions to time-dependent Schrödinger wave equation or by specific solutions of interrelated Pauli rate equations. Since the applicability of Fourier's law is questionable at nanoscale and in the case of transient heat conduction, we pay particular attention to the new physics of post-Fourier heat transport and its further consequences. For instance, the non-equilibrium conditions may establish and maintain certain degree of coherence between correlated quantum states which are involved into the energy conduction process. Understanding and gaining control of coherent manipulations of qubits (two-level quantum systems) is crucial for further development of quantum informatics. This work was supported by Pace University Start-up Grant and the Air Force Office of Scientific Research (AFOSR).

  3. TRANSIENT LAMINAR SEPARATED FLOW AROUND AN IMPULSIVELY STARTED SPHERICAL PARTICLE AT 20≤RE≤1000

    Directory of Open Access Journals (Sweden)

    FARIDA BENABBAS

    2015-12-01

    Full Text Available Numerical simulations of the axisymmetric laminar flow characteristics past a rigid sphere impulsively started are presented for Reynolds numbers from 20 to 1000. The results are obtained by solving the complete time dependant Navier-Stokes equations in vorticity and stream function formulation. A fourth order compact method is used to discretize the Poisson equation of stream function while the vorticity transport equation is solved by an alternating direction implicit method. Time evolution of flow separation angle and length of the vortex behind the sphere are reported. Time variation of the axial velocity in the vortex and the wall vorticity around the sphere are also examined. Secondary vortices are seen to be initiated at Reynolds number of 610 and for dimensionless time t about 5. Comparisons with previously published simulations and experimental data for steady state conditions show very good agreement.

  4. High-flow nasal cannula: transient fashion or new method of non-invasive ventilatory assistance?

    Science.gov (United States)

    Mosca, F; Colnaghi, M; Agosti, M; Fumagalli, M

    2012-10-01

    Respiratory failure in the premature infants remains a difficult challenge. An alternative to the use of nasal continuous positive airway pressure (NCPAP) as a non-invasive modality to support respiratory distress in premature infants has been the recent introduction of high flow nasal cannula (HFNC) devices in many neonatal units. There has been increased use of HFNC presumably because of anecdotal reports and experience that it is easy to use, and well tolerated by the infants, while experiencing decreased nasal septumerosion. The paucity of evidence regarding its efficacy and safety, would support a caution approach to the use of HFNC. Particular concern has focused on the imprecise regulation and generation of pressure that may occur at higher flows especially in the smallest of infants.

  5. Identifying the Flow Physics and Modeling Transient Forces on Two-Dimensional Wings

    Science.gov (United States)

    2016-09-02

    understanding the dynamics of these unsteady flows, and uses state-of-the- art techniques, both for measuring these phenomena in experiments (using an... art techniques, both for measuring these phenomena in experiments (using an unsteady wind tunnel at IIT), and for analyzing the data and developing...domain far-field boundary conditions. Computer Methods in Applied Mechanics and Engineering, 197:2131–2146, 2008. [35] Laurent Cordier, El Majd, B

  6. Transient flow between aquifers and surface water: analytically derived field-scale hydraulic heads and fluxes

    Directory of Open Access Journals (Sweden)

    G. H. de Rooij

    2012-03-01

    Full Text Available The increasing importance of catchment-scale and basin-scale models of the hydrological cycle makes it desirable to have a simple, yet physically realistic model for lateral subsurface water flow. As a first building block towards such a model, analytical solutions are presented for horizontal groundwater flow to surface waters held at prescribed water levels for aquifers with parallel and radial flow. The solutions are valid for a wide array of initial and boundary conditions and additions or withdrawals of water, and can handle discharge into as well as lateral infiltration from the surface water. Expressions for the average hydraulic head, the flux to or from the surface water, and the aquifer-scale hydraulic conductivity are developed to provide output at the scale of the modelled system rather than just point-scale values. The upscaled conductivity is time-variant. It does not depend on the magnitude of the flux but is determined by medium properties as well as the external forcings that drive the flow. For the systems studied, with lateral travel distances not exceeding 10 m, the circular aquifers respond very differently from the infinite-strip aquifers. The modelled fluxes are sensitive to the magnitude of the storage coefficient. For phreatic aquifers a value of 0.2 is argued to be representative, but considerable variations are likely. The effect of varying distributions over the day of recharge damps out rapidly; a soil water model that can provide accurate daily totals is preferable over a less accurate model hat correctly estimates the timing of recharge peaks.

  7. Theory and numerical application of subsurface flow and transport for transient freezing conditions

    International Nuclear Information System (INIS)

    White, M.D.

    1995-04-01

    Protective barriers are being investigated for the containment of radioactive waste within subsurface environments. Predicting the effectiveness of cryogenic barriers and near-surface barriers in temperate or arctic climates requires capabilities for numerically modeling subsurface flow and transport for freezing soil conditions. A predictive numerical model is developed herein to simulate the flow and transport of radioactive solutes for three-phase (water-ice-air) systems under freezing conditions. This physically based model simulates the simultaneous flow of water, air, heat, and radioactive solutes through variably saturated and variably frozen geologic media. Expressions for ice (frozen water) and liquid water saturations as functions of temperature, interfacial pressure differences, and osmotic potential are developed from nonhysteretic versions of the Brooks and Corey and van Genuchten functions for soil moisture retention. Aqueous relative permeability functions for variably saturated and variably frozen geologic media are developed from the Mualem and Burdine theories for predicting relative permeability of unsaturated soil. Soil deformations, caused by freezing and melting transitions, are neglected. Algorithms developed for predicting ice and liquid water saturations and aqueous-phase permeabilities were incorporated into the finite-difference based numerical simulator STOMP (Subsurface Transport Over Multiple Phases). Application of the theory is demonstrated by the solution of heat and mass transport in a horizontal cylinder of partially saturated porous media with differentially cooled ends, with the colder end held below the liquid water freezing point. This problem represents an essential capability for modeling cryogenic barriers in variably saturated geologic media

  8. Transient Flow through an Unsaturated Levee Embankment during the 2011 Mississippi River Flood

    Science.gov (United States)

    Jafari, N.; Stark, T.; Vahedifard, F.; Cadigan, J.

    2017-12-01

    The Mississippi River and corresponding tributaries drain approximately 3.23 million km2 (1.25 million mi2) or the equivalent of 41% of the contiguous United States. Approximately 2,600 km ( 1,600 miles) of earthen levees presently protect major urban cities and agricultural land against the periodic Mississippi River floods within the Lower Mississippi River Valley. The 2011 flood also severely stressed the levees and highlighted the need to evaluate the behavior of levee embankments during high water levels. The performance of earthen levees is complex because of the uncertainties in construction materials, antecedent moisture contents, hydraulic properties, and lack of field monitoring. In particular, calibration of unsaturated and saturated soil properties of levee embankment and foundation layers along with the evaluation of phreatic surface during high river stage is lacking. Due to the formation of sand boils at the Duncan Point Levee in Baton Rouge, LA during the 2011 flood event, a reconnaissance survey was conducted to collect pore-water pressures in the sand foundation using piezometers and identifying the phreatic surface at the peak river level. Transient seepage analyses were performed to calibrate the foundation and levee embankment material properties using field data collected. With this calibrated levee model, numerical experiments were conducted to characterize the effects of rainfall intensity and duration, progression of phreatic surface, and seasonal climate variability prior to floods on the performance of the levee embankment. For example, elevated phreatic surface from river floods are maintained for several months and can be compounded with rainfall to lead to slope instability.

  9. Optimization of High-Resolution Continuous Flow Analysis for Transient Climate Signals in Ice Cores

    DEFF Research Database (Denmark)

    Bigler, Matthias; Svensson, Anders; Kettner, Ernesto

    2011-01-01

    Over the past two decades, continuous flow analysis (CFA) systems have been refined and widely used to measure aerosol constituents in polar and alpine ice cores in very high-depth resolution. Here we present a newly designed system consisting of sodium, ammonium, dust particles, and electrolytic...... a depth resolution in the ice of a few millimeters which is considerably better than other CFA systems. Thus, the new system can resolve ice strata down to 10 mm thickness and has the potential of identifying annual layers in both Greenland and Antarctic ice cores throughout the last glacial cycle....

  10. Uncertainty in unprotected loss-of-heat-sink, loss-of-flow, and transient-overpower accidents.

    Energy Technology Data Exchange (ETDEWEB)

    Morris, E. E.; Nuclear Engineering Division

    2007-10-08

    The sensitivities of various output parameters to selected input parameters in unprotected combined loss of heat-sink and loss-of-flow (ULOHS), loss-of-flow (ULOF), and transient-overpower (UTOP) accidents are explored in this report. This line of investigation was suggested by R. A. Wigeland. For an initial examination of potential sensitivities, the MATWS computer program has been compiled as part of a dynamic link library (DLL) so that uncertain input parameters can be sampled from their probability distributions using the GoldSim simulation software. The MATWS program combines the point-kinetics module from the SAS4A/SASSYS computer code with a simplified representation of the reactor heat removal system. Coupling with the GoldSim software by means of a DLL not only provides a convenient mechanism for sampling the stochastic input parameters but also allows the use of various tools that are available in GoldSim for analyzing the dependence of various MATWS outputs on these parameters. Should a decision be made to continue this investigation, the techniques used to couple MATWS and GoldSim could also be applied to couple the SAS4A/SASSYS computer code with GoldSim. The work described here illustrates the type of results that can be obtained from the stochastic analysis.

  11. Transient and steady state performance analysis of power flow control in a DFIG variable speed wind turbine

    Science.gov (United States)

    Nwosu, Cajethan M.; Oti, Stephen E.; Ogbuka, Cosmas U.

    2017-01-01

    This paper presents transient and steady state performance analysis of power flow control in a 5.0 kW Doubly-Fed Induction Generator (DFIG) Variable Speed Wind Turbine (VSWT) under sub synchronous speed, super synchronous speed and synchronous speed modes of operation. Stator flux orientation is used for the control of the rotor-side converter (RSC) and DFIG whereas the grid (or stator) voltage orientation is the preferred choice for the control of the grid-side converter (GSC). In each of the three speeds modes, power is always supplied to the grid through the stator of the DFIG. The magnitude of net power (stator power plus rotor power) is less than stator power during the sub synchronous speed mode; it is greater than stator power during the super synchronous speed mode while it is equal to the stator power during the synchronous speed mode. In synchronous speed mode, the rotor power is zero indicating that power is neither supplied to the grid from the rotor nor supplied to the rotor from the grid; here the magnitude of net power is equal to stator power. The simulation results thus obtained in a MATLAB/SIMULINK environment laid credence to the controllability of power flow reversal in a DFIG-VSWT through back-to-back power electronic converter.

  12. K-FIX, Transient 2 Phase Flow Hydrodynamic in 2-D Planar or Cylindrical Geometry, Eulerian Method

    International Nuclear Information System (INIS)

    Rivard, W. C.; Torrey, M. D.

    1980-01-01

    1 - Description of problem or function: The transient dynamics of two- dimensional, two-phase flow with interfacial exchange are calculated at all flow speeds. Each phase is described in terms of its own density, velocity, and temperature. Separate sets of field equations govern the gas and liquid phase dynamics. The six field equations for the two phases couple through mass, momentum, and energy exchange. 2 - Method of solution: The equations are solved using an Eulerian finite difference technique that implicitly couples the rates of phase transitions, momentum, and energy exchange to determination of the pressure, density, and velocity fields. The implicit solution is accomplished iteratively using a point relaxation technique without linearizing the equations, thus eliminating the need for numerous derivative terms. Solutions can be obtained in one and two space dimensions in plane geometry and in cylindrical geometry with axial symmetry and zero azimuthal velocity. Solutions in spherical geometry can also be obtained in one space dimension. The geometric region of interest is divided into many finite-sized, space-fixed zones called cells which form the computing mesh. In plane geometry the cells are rectangular cylinders, in cylindrical geometry they are toroids with rectangular cross section, and in spherical geometry they are spherical shells

  13. Uncertainty in unprotected loss-of-heat-sink, loss-of-flow, and transient-overpower accidents

    International Nuclear Information System (INIS)

    Morris, E.E.

    2007-01-01

    The sensitivities of various output parameters to selected input parameters in unprotected combined loss of heat-sink and loss-of-flow (ULOHS), loss-of-flow (ULOF), and transient-overpower (UTOP) accidents are explored in this report. This line of investigation was suggested by R. A. Wigeland. For an initial examination of potential sensitivities, the MATWS computer program has been compiled as part of a dynamic link library (DLL) so that uncertain input parameters can be sampled from their probability distributions using the GoldSim simulation software. The MATWS program combines the point-kinetics module from the SAS4A/SASSYS computer code with a simplified representation of the reactor heat removal system. Coupling with the GoldSim software by means of a DLL not only provides a convenient mechanism for sampling the stochastic input parameters but also allows the use of various tools that are available in GoldSim for analyzing the dependence of various MATWS outputs on these parameters. Should a decision be made to continue this investigation, the techniques used to couple MATWS and GoldSim could also be applied to couple the SAS4A/SASSYS computer code with GoldSim. The work described here illustrates the type of results that can be obtained from the stochastic analysis

  14. TRUMP, Steady-State and Transient 1-D, 2-D and 3-D Potential Flow, Temperature Distribution

    International Nuclear Information System (INIS)

    Elrod, D.C.; Turner, W.D.

    1981-01-01

    1 - Description of problem or function: TRUMP solves a general non- linear parabolic partial differential equation describing flow in various kinds of potential fields, such as fields of temperature, pressure, or electricity and magnetism; simultaneously, it will solve two additional equations representing, in thermal problems, heat production by decomposition of two reactants having rate constants with a general Arrhenius temperature dependence. Steady- state and transient flow in one, two, or three dimensions are considered in geometrical configurations having simple or complex shapes and structures. Problem parameters may vary with spatial position, time, or primary dependent variables--temperature, pressure, or field strength. Initial conditions may vary with spatial position, and among the criteria that may be specified for ending a problem are upper and lower limits on the size of the primary dependent variable, upper limits on the problem time or on the number of time-steps or on the computer time, and attainment of steady state. 2 - Method of solution: Solutions may be obtained by use of explicit- or implicit-difference equations, or by an optimized combination of both. 3 - Restrictions on the complexity of the problem: The program currently provides for maxima of: 40 materials, 5 reactants, 105 surface conditions, 20 boundary nodes, 16 entries per tabulated function (table-length)

  15. Time scales of relaxation dynamics during transient conditions in two-phase flow: RELAXATION DYNAMICS

    Energy Technology Data Exchange (ETDEWEB)

    Schlüter, Steffen [School of Chemical, Biological and Environmental Engineering, Oregon State University, Corvallis Oregon USA; Department Soil Physics, Helmholtz-Centre for Environmental Research-UFZ, Halle Germany; Berg, Steffen [Shell Global Solutions International B.V., Rijswijk Netherlands; Li, Tianyi [School of Chemical, Biological and Environmental Engineering, Oregon State University, Corvallis Oregon USA; Vogel, Hans-Jörg [Department Soil Physics, Helmholtz-Centre for Environmental Research-UFZ, Halle Germany; Institut für Agrar- und Ernährungswissenschaften, Martin-Luther-Universität Halle-Wittenberg, Halle Germany; Wildenschild, Dorthe [School of Chemical, Biological and Environmental Engineering, Oregon State University, Corvallis Oregon USA

    2017-06-01

    The relaxation dynamics toward a hydrostatic equilibrium after a change in phase saturation in porous media is governed by fluid reconfiguration at the pore scale. Little is known whether a hydrostatic equilibrium in which all interfaces come to rest is ever reached and which microscopic processes govern the time scales of relaxation. Here we apply fast synchrotron-based X-ray tomography (X-ray CT) to measure the slow relaxation dynamics of fluid interfaces in a glass bead pack after fast drainage of the sample. The relaxation of interfaces triggers internal redistribution of fluids, reduces the surface energy stored in the fluid interfaces, and relaxes the contact angle toward the equilibrium value while the fluid topology remains unchanged. The equilibration of capillary pressures occurs in two stages: (i) a quick relaxation within seconds in which most of the pressure drop that built up during drainage is dissipated, a process that is to fast to be captured with fast X-ray CT, and (ii) a slow relaxation with characteristic time scales of 1–4 h which manifests itself as a spontaneous imbibition process that is well described by the Washburn equation for capillary rise in porous media. The slow relaxation implies that a hydrostatic equilibrium is hardly ever attained in practice when conducting two-phase experiments in which a flux boundary condition is changed from flow to no-flow. Implications for experiments with pressure boundary conditions are discussed.

  16. Electromagnetic Transients on an Underground Cable due to a Lightning Current Flowing into the Metallic Sheath

    Science.gov (United States)

    Ametani, Akihiro; Nagaoka, Naoto; Miyazaki, Daisuke; Taki, Norikazu

    This paper has investigated surge propagation and overvoltages on a coaxial cable when a lightning current flows into the metallic sheath based on experiments, EMTP simulations and analytical calculations. At the instance of the current flowing into the sheath, the core voltage becomes the same as the sheath voltage, which is given as a product of the sheath surge impedance and a half the current, following the theory of electrostatic shield. Thus no voltage difference appears between the core and the sheath across the insulator. When a traveling wave arrives at a transition point, i.e. cable termination, an insulating or crossbonding joint, the voltages change suddenly and a significant voltage appears across the insulator. An EMTP simulation shows that the overvoltage across the insulator exceeds 1200kV at a crossbonded node on a 400kV underground cable when an ac source voltage is in the opposite polarity of the lightning surge voltage on the sheath and the inductance of a crossbonding lead wire is taken into account. The high overvoltage appears in a narrow region of the cable between the current injected node and the crossbonded node due to traveling wave reflection between the nodes. The phenomenon investigated may occur if there exists a pinhole or a watertree on an underground cable.

  17. Transient behavior of simultaneous flow of gas and surfactant solution in consolidated porous media

    Energy Technology Data Exchange (ETDEWEB)

    Baghdikian, S.Y.; Handy, L.L.

    1991-07-01

    The main objective of this experimental research was to investigate the mechanisms of foam generation and propagation in porous media. Results obtained give an insight into the conditions of foam generation and propagation in porous media. The rate of propagation of foam is determined by the rates of lamellae generation, destruction, and trapping. Several of the factors that contribute to foam generation have studied with Chevron Chaser SD1000 surfactant. Interfacial tension (IFT) measurements were performed using a spinning drop apparatus. The IFT of two surfactant samples of different concentrations were measured with dodecane and crude oil from the Huntington Beach Field as a function of temperature and time. Foam was used as an oil-displacing fluid. However, when displacing oil, foam was not any more effective than simultaneous brine and gas injection. A series of experiments was performed to study the conditions of foam generation in Berea sandstone cores. Results show that foam may be generated in sandstone at low flow velocities after extended incubation periods. The effect of pregenerating foam before injection into the sandstone was also studied. The pressure profiles in the core were monitored using three pressure taps along the length of the core. A systematic study of foaming with different fluid velocities and foam qualities provides extensive data for foam flow conditions. 134 refs., 57 figs., 2 tabs.

  18. An adaptive optimisation scheme for controlling air flow process with satisfactory transient performance

    Directory of Open Access Journals (Sweden)

    Sivakumar Dakshinamurthy

    2010-07-01

    Full Text Available A non-identifier-based adaptive PI controller is designed using a gradient approach to improve the performance of a control system when device aging and environmental factors degrade the efficiency of the process. The design approach is based on the model reference adaptive control technique. The controller drives the difference (error between the process response and desired model output to zero asymptotically at a rate constrained by the desired characteristics of the model. The tuning rules are designed and justified for a non-linear process with dominant dynamics of second order. The advantage of this method for tracking and regulation compared to adaptive MIT control was validated in real time by conducting experiments on a laboratory air flow control system using the dSPACE interface in the SIMULINK software. The experimental results show that the process with adaptive PI controller has better dynamic performance and robustness than that with traditional adaptive MIT controller.

  19. Numerical Simulation of Transient Free Convection Flow and Heat Transfer in a Porous Medium

    Directory of Open Access Journals (Sweden)

    Rajesh Sharma

    2013-01-01

    Full Text Available The coupled momentum and heat transfer in unsteady, incompressible flow along a semi-infinite vertical porous moving plate adjacent to an isotropic porous medium with viscous dissipation effect are investigated. The Darcy-Forchheimer nonlinear drag force model which includes the effects of inertia drag forces is employed. The governing differential equations of the problem are transformed into a system of nondimensional differential equations which are solved numerically by the finite element method (FEM. The non-dimensional velocity and temperature profiles are presented for the influence of Darcy number, Forchheimer number, Grashof number, Eckert number, Prandtl number, plate velocity, and time. The Nusselt number is also evaluated and compared with finite difference method (FDM, which shows excellent agreement.

  20. Effects of intracavitary blood flow and electrode-target distance on radiofrequency power required for transient conduction block in a Langendorff-perfused canine model

    NARCIS (Netherlands)

    Simmers, T. A.; de Bakker, J. M.; Coronel, R.; Wittkampf, F. H.; van Capelle, F. J.; Janse, M. J.; Hauer, R. N.

    1998-01-01

    OBJECTIVES: We sought to quantify the effects of electrode-target distance and intracavitary blood flow on radiofrequency (RF) power required to induce transient conduction block, using a Langendorff-perfused canine ablation model. BACKGROUND: Given the thermally mediated nature of RF catheter

  1. A new algorithm of global tightly-coupled transient heat transfer based on quasi-steady flow to the conjugate heat transfer problem

    Directory of Open Access Journals (Sweden)

    Fanchao Meng

    2016-09-01

    Full Text Available Concerning the specific demand on solving the long-term conjugate heat transfer (CHT problem, a new algorithm of the global tightly-coupled transient heat transfer based on the quasi-steady flow field is further put forward. Compared to the traditional loosely-coupled algorithm, the computational efficiency is further improved with the greatly reduced update frequency of the flow field, and moreover the update step of the flow field can be reasonably determined by using the engineering empirical formula of the Nusselt number based on the changes of the inlet and outlet boundary conditions. Taking a duct heated by inner forced air flow heating process as an example, the comparing results to the tightly-coupled transient calculation by Fluent software shows that the new algorithm can significantly improve the computational efficiency with a reasonable accuracy on the transient temperature distribution, such as the computing time is reduced to 22.8% and 40% while the duct wall temperature deviation are 7% and 5% respectively using two flow update time step of 100 s and 50 s on the variable inlet-flow rate conditions.

  2. The verification of NAMMU using HYDROCOIN Level 1 cases 1 and 7: transient flow from a borehole and saturated flow through a shallow land disposal facility

    International Nuclear Information System (INIS)

    Herbert, A.

    1985-10-01

    The numerical accuracy of the finite-element groundwater flow code NAMMU has been verified using test cases 1 and 7 from HYDROCOIN Level 1. Case 1 compares calculated results with an analytic solution to an idealised transient borehole experiment in a porous medium with a single horizontal fracture. The numerical results are in excellent agreement with the analytic solution, both for the pressure values and for the gradients. Our use of lower-dimensional elements to represent fractures is also verified in this test case, again with excellent agreement. Case 7 involves calculating flow through an idealised shallow land disposal facility in argillaceous media, and verifies a code's ability to model the spacially varying permeabilities which would be found in the vicinity of this type of facility. Since there is no analytical solution for this case, the results from independently developed codes have been intercompared. Considerable refinement of the grid was found necessary in the neighbourhood of the concrete engineered barriers, and near the outflow. With this refinement, the results from NAMMU compared well with results from other codes participating in the HYDROCOIN project. (author)

  3. Applying Hybrid Heuristic Approach to Identify Contaminant Source Information in Transient Groundwater Flow Systems

    Directory of Open Access Journals (Sweden)

    Hund-Der Yeh

    2014-01-01

    Full Text Available Simultaneous identification of the source location and release history in aquifers is complicated and time-consuming if the release of groundwater contaminant source varies in time. This paper presents an approach called SATSO-GWT to solve complicated source release problems which contain the unknowns of three location coordinates and several irregular release periods and concentrations. The SATSO-GWT combines with ordinal optimization algorithm (OOA, roulette wheel approach, and a source identification algorithm called SATS-GWT. The SATS-GWT was developed based on simulated annealing, tabu search, and three-dimensional groundwater flow and solute transport model MD2K-GWT. The OOA and roulette wheel method are utilized mainly to reduce the size of feasible solution domain and accelerate the identification of the source information. A hypothetic site with one contaminant source location and two release periods is designed to assess the applicability of the present approach. The results indicate that the performance of SATSO-GWT is superior to that of SATS-GWT. In addition, the present approach works very effectively in dealing with the cases which have different initial guesses of source location and measurement errors in the monitoring points as well as problems with large suspicious areas and several source release periods and concentrations.

  4. Characterization of the startup transient electrokinetic flow in rectangular channels of arbitrary dimensions, zeta potential distribution, and time-varying pressure gradient.

    Science.gov (United States)

    Miller, Andrew; Villegas, Arturo; Diez, F Javier

    2015-03-01

    The solution to the startup transient EOF in an arbitrary rectangular microchannel is derived analytically and validated experimentally. This full 2D transient solution describes the evolution of the flow through five distinct periods until reaching a final steady state. The derived analytical velocity solution is validated experimentally for different channel sizes and aspect ratios under time-varying pressure gradients. The experiments used a time resolved micro particle image velocimetry technique to calculate the startup transient velocity profiles. The measurements captured the effect of time-varying pressure gradient fields derived in the analytical solutions. This is tested by using small reservoirs at both ends of the channel which allowed a time-varying pressure gradient to develop with a time scale on the order of the transient EOF. Results showed that under these common conditions, the effect of the pressure build up in the reservoirs on the temporal development of the transient startup EOF in the channels cannot be neglected. The measurements also captured the analytical predictions for channel walls made of different materials (i.e., zeta potentials). This was tested in channels that had three PDMS and one quartz wall, resulting in a flow with an asymmetric velocity profile due to variations in the zeta potential between the walls. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A ‘win win’ mechanism for low-drag transients in controlled two-dimensional channel flow and its implications for sustained drag reduction

    Science.gov (United States)

    Bewley, Thomas R.; Morten Aamo, Ole

    2004-01-01

    A simple pressure-based feedback control strategy for wall-transpiration control of incompressible unsteady two-dimensional channel flow was recently investigated by Aamo, Krstic & Bewley (2003). Nonlinear two-dimensional channel flow simulations which implemented this control strategy resulted in flow transients with instantaneous drag far lower than that of the corresponding laminar flow. The present article examines the physical mechanism by which this very low level of instantaneous drag was attained. It then explores the possibility of achieving sustained drag reductions to below the laminar level by initiating such low-drag transients on a periodic basis. All attempts at sustaining the mean flow drag below the laminar level fail, perhaps providing indirect evidence in favour of the conjecture that the laminar state might provide a fundamental ‘performance limitation’ in such flows. Mathematical analysis of two-dimensional and three-dimensional channel-flow systems establishes a direct link between the average drag increase due to flow-field unsteadiness and a weighted space/time average of the Reynolds stress. Phenomenological justification of the conjecture is provided by a Reynolds analogy between convective momentum transport and convective heat transport. Proof of the conjecture remains an open problem.

  6. Unsteady MHD flow of visco-elastic Oldroydian fluid with transient pressure gradient through a rectangular channel: with a possible generalisation

    International Nuclear Information System (INIS)

    Sengupta, P.R.; Kundu, Shyamal Kumar

    2001-01-01

    In this paper, we have determined the unsteady MHD flow of visco-elastic fluid with transient pressure gradient through a rectangular channel. Here we have calculated the velocity profile of a fluid element of the titled problem theoretically and numerically. Then an empirical model of generalisation has been made as proposed by the senior author Dr P.K. Sengupta to cover a wide range of visco-elastic fluids admitting new class of generalised visco-elastic fluids. The problem of unsteady MHD flow of such visco-elastic fluids with transient pressure gradient through a rectangular channel has been calculated. From this generalisation the corresponding flow of Oldroydian first order, second order and n-th order, Maxwell first order, second order and n-th order, Rivlen-Ericksen first order, second order and n-th order fluid and first order special type of Walters fluid as well as ordinary fluids have been derived. (author)

  7. Analysis of Water Hammer with Different Closing Valve Laws on Transient Flow of Hydrogen-Natural Gas Mixture

    Directory of Open Access Journals (Sweden)

    Norazlina Subani

    2015-01-01

    Full Text Available Water hammer on transient flow of hydrogen-natural gas mixture in a horizontal pipeline is analysed to determine the relationship between pressure waves and different modes of closing and opening of valves. Four types of laws applicable to closing valve, namely, instantaneous, linear, concave, and convex laws, are considered. These closure laws describe the speed variation of the hydrogen-natural gas mixture as the valve is closing. The numerical solution is obtained using the reduced order modelling technique. The results show that changes in the pressure wave profile and amplitude depend on the type of closing laws, valve closure times, and the number of polygonal segments in the closing function. The pressure wave profile varies from square to triangular and trapezoidal shape depending on the type of closing laws, while the amplitude of pressure waves reduces as the closing time is reduced and the numbers of polygonal segments are increased. The instantaneous and convex closing laws give rise to minimum and maximum pressure, respectively.

  8. Assessment of Effectiveness of Geologic Isolation Systems. Variable thickness transient ground-water flow model. Volume 2. Users' manual

    International Nuclear Information System (INIS)

    Reisenauer, A.E.

    1979-12-01

    A system of computer codes to aid in the preparation and evaluation of ground-water model input, as well as in the computer codes and auxillary programs developed and adapted for use in modeling major ground-water aquifers is described. The ground-water model is interactive, rather than a batch-type model. Interactive models have been demonstrated to be superior to batch in the ground-water field. For example, looking through reams of numerical lists can be avoided with the much superior graphical output forms or summary type numerical output. The system of computer codes permits the flexibility to develop rapidly the model-required data files from engineering data and geologic maps, as well as efficiently manipulating the voluminous data generated. Central to these codes is the Ground-water Model, which given the boundary value problem, produces either the steady-state or transient time plane solutions. A sizeable part of the codes available provide rapid evaluation of the results. Besides contouring the new water potentials, the model allows graphical review of streamlines of flow, travel times, and detailed comparisons of surfaces or points at designated wells. Use of the graphics scopes provide immediate, but temporary displays which can be used for evaluation of input and output and which can be reproduced easily on hard copy devices, such as a line printer, Calcomp plotter and image photographs

  9. Simulating adsorption of U(VI) under transient groundwater flow and hydrochemistry: Physical versus chemical nonequilibrium model

    Science.gov (United States)

    Greskowiak, J.; Hay, M.B.; Prommer, H.; Liu, C.; Post, V.E.A.; Ma, R.; Davis, J.A.; Zheng, C.; Zachara, J.M.

    2011-01-01

    Coupled intragrain diffusional mass transfer and nonlinear surface complexation processes play an important role in the transport behavior of U(VI) in contaminated aquifers. Two alternative model approaches for simulating these coupled processes were analyzed and compared: (1) the physical nonequilibrium approach that explicitly accounts for aqueous speciation and instantaneous surface complexation reactions in the intragrain regions and approximates the diffusive mass exchange between the immobile intragrain pore water and the advective pore water as multirate first-order mass transfer and (2) the chemical nonequilibrium approach that approximates the diffusion-limited intragrain surface complexation reactions by a set of multiple first-order surface complexation reaction kinetics, thereby eliminating the explicit treatment of aqueous speciation in the intragrain pore water. A model comparison has been carried out for column and field scale scenarios, representing the highly transient hydrological and geochemical conditions in the U(VI)-contaminated aquifer at the Hanford 300A site, Washington, USA. It was found that the response of U(VI) mass transfer behavior to hydrogeochemically induced changes in U(VI) adsorption strength was more pronounced in the physical than in the chemical nonequilibrium model. The magnitude of the differences in model behavior depended particularly on the degree of disequilibrium between the advective and immobile phase U(VI) concentrations. While a clear difference in U(VI) transport behavior between the two models was noticeable for the column-scale scenarios, only minor differences were found for the Hanford 300A field scale scenarios, where the model-generated disequilibrium conditions were less pronounced as a result of frequent groundwater flow reversals. Copyright 2011 by the American Geophysical Union.

  10. Shape factors inclusion in a one‐dimensional, transient two‐fluid model for stratified and slug flow simulations in pipes

    OpenAIRE

    Bonzanini, Arianna; Picchi, Davide; Ferrari, Marco; Poesio, Pietro

    2017-01-01

    In previous works, (Ferrari et al., 2017) have shown that a onedimensional, hyperbolic, transient five equations two-fluid model is able to numerically describe stratified, wavy, and slug flow in horizontal and near-horizontal pipes. Slug statistical characteristics, such as slug velocity, frequency, and length can be numerically predicted with results in good agreement with experimental data and well-known empirical relations. In this model some approximated and simplified assumptions are ad...

  11. Numerical solution of one-dimensional transient, two-phase flows with temporal fully implicit high order schemes: Subcooled boiling in pipes

    Energy Technology Data Exchange (ETDEWEB)

    López, R., E-mail: ralope1@ing.uc3m.es; Lecuona, A., E-mail: lecuona@ing.uc3m.es; Nogueira, J., E-mail: goriba@ing.uc3m.es; Vereda, C., E-mail: cvereda@ing.uc3m.es

    2017-03-15

    Highlights: • A two-phase flows numerical algorithm with high order temporal schemes is proposed. • Transient solutions route depends on the temporal high order scheme employed. • ESDIRK scheme for two-phase flows events exhibits high computational performance. • Computational implementation of the ESDIRK scheme can be done in a very easy manner. - Abstract: An extension for 1-D transient two-phase flows of the SIMPLE-ESDIRK method, initially developed for incompressible viscous flows by Ijaz is presented. This extension is motivated by the high temporal order of accuracy demanded to cope with fast phase change events. This methodology is suitable for boiling heat exchangers, solar thermal receivers, etc. The methodology of the solution consist in a finite volume staggered grid discretization of the governing equations in which the transient terms are treated with the explicit first stage singly diagonally implicit Runge-Kutta (ESDIRK) method. It is suitable for stiff differential equations, present in instant boiling or condensation processes. It is combined with the semi-implicit pressure linked equations algorithm (SIMPLE) for the calculation of the pressure field. The case of study consists of the numerical reproduction of the Bartolomei upward boiling pipe flow experiment. The steady-state validation of the numerical algorithm is made against these experimental results and well known numerical results for that experiment. In addition, a detailed study reveals the benefits over the first order Euler Backward method when applying 3rd and 4th order schemes, making emphasis in the behaviour when the system is subjected to periodic square wave wall heat function disturbances, concluding that the use of the ESDIRK method in two-phase calculations presents remarkable accuracy and computational advantages.

  12. Transient calibration of a groundwater-flow model of Chimacum Creek Basin and vicinity, Jefferson County, Washington: a supplement to Scientific Investigations Report 2013-5160

    Science.gov (United States)

    Jones, Joseph L.; Johnson, Kenneth H.

    2013-01-01

    A steady-state groundwater-flow model described in Scientific Investigations Report 2013-5160, ”Numerical Simulation of the Groundwater-Flow System in Chimacum Creek Basin and Vicinity, Jefferson County, Washington” was developed to evaluate potential future impacts of growth and of water-management strategies on water resources in the Chimacum Creek Basin. This supplement to that report describes the unsuccessful attempt to perform a calibration to transient conditions on the model. The modeled area is about 64 square miles on the Olympic Peninsula in northeastern Jefferson County, Washington. The geologic setting for the model area is that of unconsolidated deposits of glacial and interglacial origin typical of the Puget Sound Lowlands. The hydrogeologic units representing aquifers are Upper Aquifer (UA, roughly corresponding to recessional outwash) and Lower Aquifer (LA, roughly corresponding to advance outwash). Recharge from precipitation is the dominant source of water to the aquifer system; discharge is primarily to marine waters below sea level and to Chimacum Creek and its tributaries. The model is comprised of a grid of 245 columns and 313 rows; cells are a uniform 200 feet per side. There are six model layers, each representing one hydrogeologic unit: (1) Upper Confining unit (UC); (2) Upper Aquifer unit (UA); (3) Middle Confining unit (MC); (4) Lower Aquifer unit (LA); (5) Lower Confining unit (LC); and (6) Bedrock unit (OE). The transient simulation period (October 1994–September 2009) was divided into 180 monthly stress periods to represent temporal variations in recharge, discharge, and storage. An attempt to calibrate the model to transient conditions was unsuccessful due to instabilities stemming from oscillations in groundwater discharge to and recharge from streamflow in Chimacum Creek. The model as calibrated to transient conditions has mean residuals and standard errors of 0.06 ft ±0.45 feet for groundwater levels and 0.48 ± 0.06 cubic

  13. Proceedings of the CSNI Specialist Meeting on Transient Two-Phase Flow - Current Issues in System Thermal Hydraulics

    International Nuclear Information System (INIS)

    Reocreux, M.; Rubinstein, M.C.

    1992-01-01

    The 4. Specialists' Meeting on Transient Two Phase Flow was organized by the Safety Research Department of the French Nuclear Safety and Protection Institute at the request of the OECD Committee for the Safety of Nuclear Installations. After Toronto in 1976, Paris in 1978 and Pasadena in 1981, the Aix-en-Provence meeting was in keeping with the course of studies initiated by the Thermalhydraulic Systems Behavior Task Group of the Principal Working Group No.2 for discussing the achievements and defining the needs of safety research in accident thermal-hydraulics. 60 Specialists from 14 Countries (Belgium, Canada, Finland, France, Germany, Italy, Japan, the Netherlands, the United Kingdom, the USA, Spain, Sweden, Switzerland, Taiwan) attended the meeting, representing a large spectrum of experts from National Safety Authorities, Research Laboratories, Universities, Vendors and Utilities. These specialists had to review the 15-year research period which had elapsed since the last meetings. This period had been characterized by the issuance of the large thermalhydraulic computer codes for LWR accidents, the performance of several hundreds of separate effect tests for the development and the qualification of the physical models, the carrying-out of the large experimental programmes on system loops (up to scale 1) for verifying the computer codes. Although this research was mainly characterized by remarkable success, limitations still exist. In a safety approach, there need to be well identified and handled, and the specialists were asked to exchange their views in order to determine which solutions they expected to be affordable in the future. Safety applications have already started which use these latest research achievements. They raise specific problems such as the use of validation matrices, the evaluation of uncertainties, the identification and the control of unavoidable users' effects. The specialists were required to exchange their experience of applications

  14. Particle Tracking-Based Strategies For Simulating Transport in a Transient Groundwater Flow Field at Yucca Flat, Nevada Test Site, USA

    Science.gov (United States)

    Keating, E. H.; Srinivasan, G.; Kang, Q.; Li, C.; Dash, Z.; Kwicklis, E. M.

    2009-12-01

    Developing probabilistic-based calculations of contaminant concentrations over the next 1000 years at Yucca Flat, Nevada Test site, require tremendous computational effort in this highly complex hydrogeologic surface environment. The sources of contamination, underground nuclear tests conducted between 1951 and 1992, not only released radionuclides to the subsurface but also created abrupt, significant changes in rock properties and caused large transients in the measured hydraulic gradients. To efficiently model contaminant migration from these sources we use a particle-based approach within a transient flow field. Here, we present results using two methods; first, an explicit representation of time-varying sources using large numbers of particles introduced at source-specific rates over time, each representing a unique mass of solute. This method provides good results, but is computationally expensive since sensitivity to uncertainty in source term and transport parameters can only be explored with discrete process-model runs. The second method employs a convolution method (PLUMECALC) which can efficiently consider a large number of variations in the source terms and in certain transport parameters with a single process-model run. Implementation of this second approach required extension of the existing methodology to conditions of transient flow. We find very good comparison between the two methods on small test problems and excellent computational advantages when applying the convolution method in the NTS application

  15. Fluid Structure Interaction in a Cold Flow Test and Transient CFD Analysis of Out-of-Round Nozzles

    Science.gov (United States)

    Ruf, Joseph; Brown, Andrew; McDaniels, David; Wang, Ten-See

    2010-01-01

    This viewgraph presentation describes two nozzle fluid flow interactions. They include: 1) Cold flow nozzle tests with fluid-structure interaction at nozzle separated flow; and 2) CFD analysis for nozzle flow and side loads of nozzle extensions with various out-of-round cases.

  16. Application of computational fluid dynamics and fluid structure interaction techniques for calculating the 3D transient flow of journal bearings coupled with rotor systems

    Science.gov (United States)

    Li, Qiang; Yu, Guichang; Liu, Shulian; Zheng, Shuiying

    2012-09-01

    Journal bearings are important parts to keep the high dynamic performance of rotor machinery. Some methods have already been proposed to analysis the flow field of journal bearings, and in most of these methods simplified physical model and classic Reynolds equation are always applied. While the application of the general computational fluid dynamics (CFD)-fluid structure interaction (FSI) techniques is more beneficial for analysis of the fluid field in a journal bearing when more detailed solutions are needed. This paper deals with the quasi-coupling calculation of transient fluid dynamics of oil film in journal bearings and rotor dynamics with CFD-FSI techniques. The fluid dynamics of oil film is calculated by applying the so-called "dynamic mesh" technique. A new mesh movement approach is presented while the dynamic mesh models provided by FLUENT are not suitable for the transient oil flow in journal bearings. The proposed mesh movement approach is based on the structured mesh. When the journal moves, the movement distance of every grid in the flow field of bearing can be calculated, and then the update of the volume mesh can be handled automatically by user defined function (UDF). The journal displacement at each time step is obtained by solving the moving equations of the rotor-bearing system under the known oil film force condition. A case study is carried out to calculate the locus of the journal center and pressure distribution of the journal in order to prove the feasibility of this method. The calculating results indicate that the proposed method can predict the transient flow field of a journal bearing in a rotor-bearing system where more realistic models are involved. The presented calculation method provides a basis for studying the nonlinear dynamic behavior of a general rotor-bearing system.

  17. Measurements of the effects of a wire-wrap spacer on the thermalhydraulics of heated annular upward flow of supercritical R134a in steady and transient conditions

    Energy Technology Data Exchange (ETDEWEB)

    Reinink, S.; Copping, A.; Kedare, S.; Hovell, K.; Yaras, M.I. [Carleton University, Ottawa (Canada)

    2014-07-01

    Experiments were conducted at supercritical pressures and temperatures on a vertically-oriented annular heating rod with a wire-wrap spacer using upward-flowing R134a to determine the effect of a wire-wrap spacer on heat transfer in proximity of the pseudocritical point. Measurements were taken at quasi-steady-state and pressure-transient conditions. During each instance of deteriorated heat transfer, the Nusselt number is greater than values predicted by the Dittus-Boelter correlation. Heat transfer during the pressure transients is observed to be insensitive to the time rate of change of the fluid pressure, which implies that the transience does not affect the instantaneous state of the heat-transfer process. (author)

  18. Evaluation of dynamic loads induced by transient regimes of fluid flows in the pipe systems and devices of reducing the loads and their effects

    International Nuclear Information System (INIS)

    Serban, Viorel; Chirita, Alexandru Mihai; Androne, Marian; Alexandru, Constantin; Ciuca, Camelia; Badara, Janina; Alexandru, Carmen

    1995-01-01

    The paper presents the analytic methods for estimating the dynamic effects induced in pipe systems in transient regimes. They are based on computation programs developed in order to check the behaviour of ECCS and EWS under 'water hammer effect' and the behaviour of the primary circuit system under stresses caused by pipe cracks. Computation examples are presented in order to emphasize the capabilities of the programs to model transient phenomena in complex pipe networks. The overpressure induced by the water hammer effect, as revealed by comparing several transient regimes, depends on the fluid viscosity, the initial speed, the duration of starting the transient regime, the system rigidity, etc. Values several ten times higher that the initial one could be thus reached. An overview of new types of devices designed for damping the effect of water hammer phenomenon, as well as of sustaining supports for pipe systems and equipment able to damp the vibrations produced by the transient regimes of fluid flows and seismic movements is presented. These devices have also to cope with the high shocks produced by pipe breakage as well as high static loads. The paper contains the following sections: 1. Introduction; 2. Evaluating dynamic loads associated to the water hammer phenomenon; 3. Determining loads associated to the water hammer phenomenon for the ECC system of the Cernavoda NPP Unit 1; 4. Device for reducing the water hammer effects; 5. Evaluating dynamic loads associated to pipe cracks; 6. Determining loads associated to pipe cracks in the Cernavoda NPP primary circuit; 7. Devices for absorbing and damping the dynamic loads in pipe systems and equipment; 8. Conclusions. (authors)

  19. Strategy for solving semi-analytically three-dimensional transient flow in a coupled N-layer aquifer system

    NARCIS (Netherlands)

    Veling, E.J.M.; Maas, C.

    2008-01-01

    Efficient strategies for solving semi-analytically the transient groundwater head in a coupled N-layer aquifer system phi(i)(r, z, t), i = 1, ..., N, with radial symmetry, with full z-dependency, and partially penetrating wells are presented. Aquitards are treated as aquifers with their own

  20. Transient thermal, hydraulic, and mechanical analysis of a counter flow offset strip fin intermediate heat exchanger using an effective porous media approach

    Science.gov (United States)

    Urquiza, Eugenio

    This work presents a comprehensive thermal hydraulic analysis of a compact heat exchanger using offset strip fins. The thermal hydraulics analysis in this work is followed by a finite element analysis (FEA) to predict the mechanical stresses experienced by an intermediate heat exchanger (IHX) during steady-state operation and selected flow transients. In particular, the scenario analyzed involves a gas-to-liquid IHX operating between high pressure helium and liquid or molten salt. In order to estimate the stresses in compact heat exchangers a comprehensive thermal and hydraulic analysis is needed. Compact heat exchangers require very small flow channels and fins to achieve high heat transfer rates and thermal effectiveness. However, studying such small features computationally contributes little to the understanding of component level phenomena and requires prohibitive computational effort using computational fluid dynamics (CFD). To address this issue, the analysis developed here uses an effective porous media (EPM) approach; this greatly reduces the computation time and produces results with the appropriate resolution [1]. This EPM fluid dynamics and heat transfer computational code has been named the Compact Heat Exchanger Explicit Thermal and Hydraulics (CHEETAH) code. CHEETAH solves for the two-dimensional steady-state and transient temperature and flow distributions in the IHX including the complicating effects of temperature-dependent fluid thermo-physical properties. Temperature- and pressure-dependent fluid properties are evaluated by CHEETAH and the thermal effectiveness of the IHX is also calculated. Furthermore, the temperature distribution can then be imported into a finite element analysis (FEA) code for mechanical stress analysis using the EPM methods developed earlier by the University of California, Berkeley, for global and local stress analysis [2]. These simulation tools will also allow the heat exchanger design to be improved through an

  1. Analysis of transient heat flow to thick-walled plates and cylinders. [to determine gas heat transfer coefficient

    Science.gov (United States)

    Powell, W. B.

    1973-01-01

    A methodology is described for the analysis of a transient temperature measurement made in a flat or curved plate subjected to convective heat transfer, such that the surface heat flux, the hot-gas temperture, and the gas heat transfer coefficient can be determined. It is shown that if the transient temperature measurement is made at a particular point located nearly midway in the thickness of the plate there is an important simplification in the data analysis process, in that the factor relating the surface heat flux to the measured rate of rise of temperature becomes invariant for a Fourier Number above 0.60 and for all values of the Biot Number. Parameters are derived, tabulated, and plotted which enable straightforward determination of the surface heat flux, the hot-gas temperature, of the plate, the rate of rise of temperature, the plate thickness and curvature, and the mean thermal properties of the plate material at the test temperature.

  2. Electrophoretic deposition of titania nanoparticles: Wet density of ...

    Indian Academy of Sciences (India)

    Administrator

    Electrophoretic deposition (EPD); electro-osmotic flow; titania nanoparticles; triethanolamine. (TEA); wet density. 1. .... (25 °C) and atmospheric pressure. The immersion weight ... Wet density of deposits and velocity of electro-osmotic flow against TEA concentration at (a) 60 and (b) 200 V and longer EPD times (360 s).

  3. Analysis of a high pressure ATWS [anticipated transient without scram] with very low make-up flow

    International Nuclear Information System (INIS)

    Wagner, K.C.

    1988-10-01

    A series of calculations were performed to analyze the response of General Electric Company's (GE) advanced boiling water reactor (ABWR) during an anticipated transient without scram (ATWS). This work investigated the early plant response with an assumed failure or manual inhibit of the high pressure core flooder (HPCF). Consequently, the reactor core isolation cooling (RCIC) and control rod drive (CRD) systems are the only sources of high pressure injection available to maintain core cooling. Steam leaving the reactor pressure vessel was diverted to the pressure suppression pool (PSP) via the steam line and the safety relief valves. The combination of an unscrammed core and the CRD and RCIC injection sources make this a particularly challenging transient. System energy balance calculations were performed to predict the core power and PSP heat-up rate. The amount of vessel vapor superheat and the PSP temperature were found to significantly affect the resultant core power. Consequently, detailed thermal-hydraulic calculations were performed to simulate the system response during the postulated transient. 15 refs., 15 figs., 4 tabs

  4. Summary on experimental methods for statistical transient analysis of two-phase gas-liquid flow. [BWR, PWR, and LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Delhaye, J M; Jones, Jr, O C

    1976-06-01

    Much work has been done in the study of two-phase gas-liquid flows. Although it has been recognized superficially that such flows are not homogeneous in general, little attention has been paid to the inherent discreteness of the two-phase systems. Only relatively recently have fluctuating characteristics of two-phase flows been studied in detail. As a result, new experimental devices and techniques have been developed for use in measuring quantities previously ignored. This report reviews and summarizes most of these methods in an effort to emphasize the importance of the fluctuating nature of these flows and as a guide to further research in this field.

  5. Multi-instrument mapping of the small-scale flow dynamics related to a cusp auroral transient

    Directory of Open Access Journals (Sweden)

    K. Oksavik

    2005-10-01

    Full Text Available In this paper we focus on flux transfer events (FTEs and poleward moving auroral forms (PMAFs in the cusp region, combining data from the EISCAT Svalbard radar, SuperDARN HF radars, ground-based optics, and three low-altitude polar-orbiting spacecraft. During an interval of southward interplanetary magnetic field the EISCAT Svalbard radar tracked a train of narrow flow channels drifting into the polar cap. One 30-60 km wide flow channel surrounded by flow running in the opposite direction is studied in great detail from when it formed equatorward of the cusp aurora, near magnetic noon, until it left the field-of-view and disappeared into the polar cap. Satellite data shows that the flow channel was on open field lines. The flow pattern is consistent with field-aligned currents on the sides of the flow channel; with a downward current on the equatorward side, and an upward current on the poleward side. The poleward edge of the flow channel was coincident with a PMAF that separated from the background cusp aurora and drifted into the polar cap. A passage of the DMSP F13 spacecraft confirms that the FTE flow channel was still discernable over 15 minutes after it formed, as the spacecraft revealed a 30–40 km wide region of sunward flow within the anti-sunward background convection. From the dimensions of the flow channel we estimate that the magnetic flux contained in the event was at least 1 MWb. This data set also shows that Birkeland current filaments often seen by low-altitude spacecraft in the cusp/mantle are really associated with individual FTE events or a train of FTEs in progress. As the region 0 or cusp/mantle current represents the statistical average consistent with the large-scale flow pattern, we therefore introduce a new term – FTE currents – to denote the unique pair of Birkeland current sheets that are associated with individual meso-scale FTE flow disturbances. The poleward moving auroral forms (PMAFs, often referred to in

  6. Multi-instrument mapping of the small-scale flow dynamics related to a cusp auroral transient

    Directory of Open Access Journals (Sweden)

    K. Oksavik

    2005-10-01

    Full Text Available In this paper we focus on flux transfer events (FTEs and poleward moving auroral forms (PMAFs in the cusp region, combining data from the EISCAT Svalbard radar, SuperDARN HF radars, ground-based optics, and three low-altitude polar-orbiting spacecraft. During an interval of southward interplanetary magnetic field the EISCAT Svalbard radar tracked a train of narrow flow channels drifting into the polar cap. One 30-60 km wide flow channel surrounded by flow running in the opposite direction is studied in great detail from when it formed equatorward of the cusp aurora, near magnetic noon, until it left the field-of-view and disappeared into the polar cap. Satellite data shows that the flow channel was on open field lines. The flow pattern is consistent with field-aligned currents on the sides of the flow channel; with a downward current on the equatorward side, and an upward current on the poleward side. The poleward edge of the flow channel was coincident with a PMAF that separated from the background cusp aurora and drifted into the polar cap. A passage of the DMSP F13 spacecraft confirms that the FTE flow channel was still discernable over 15 minutes after it formed, as the spacecraft revealed a 30–40 km wide region of sunward flow within the anti-sunward background convection. From the dimensions of the flow channel we estimate that the magnetic flux contained in the event was at least 1 MWb. This data set also shows that Birkeland current filaments often seen by low-altitude spacecraft in the cusp/mantle are really associated with individual FTE events or a train of FTEs in progress. As the region 0 or cusp/mantle current represents the statistical average consistent with the large-scale flow pattern, we therefore introduce a new term – FTE currents – to denote the unique pair of Birkeland current sheets that are associated with individual meso-scale FTE flow disturbances. The poleward moving auroral forms (PMAFs, often referred to in

  7. Summary of transient management

    International Nuclear Information System (INIS)

    Sheron, B.W.

    1984-01-01

    This chapter reviews the papers on evaluating and managing transients, as given at the American Nuclear Society Topical Meeting on Anticipated and Abnormal Plant Transients in Light Water Reactors. Transient management involves both diverse and related areas such as analysis, systems performance, human performance, procedures, and training. State-of-the-art simulators are being improved to solve the constitutive equations for two-phase fluid flow by the development of a new generation of analysis codes which are simpler and faster than earlier codes. Both the US NRC and the nuclear industry are criticized for solving problems by adding additional requirements for the reactor operator rather than by recognizing design deficiencies

  8. Study of microvascular non-Newtonian blood flow modulated by electroosmosis.

    Science.gov (United States)

    Tripathi, Dharmendra; Yadav, Ashu; Anwar Bég, O; Kumar, Rakesh

    2018-05-01

    An analytical study of microvascular non-Newtonian blood flow is conducted incorporating the electro-osmosis phenomenon. Blood is considered as a Bingham rheological aqueous ionic solution. An externally applied static axial electrical field is imposed on the system. The Poisson-Boltzmann equation for electrical potential distribution is implemented to accommodate the electrical double layer in the microvascular regime. With long wavelength, lubrication and Debye-Hückel approximations, the boundary value problem is rendered non-dimensional. Analytical solutions are derived for the axial velocity, volumetric flow rate, pressure gradient, volumetric flow rate, averaged volumetric flow rate along one time period, pressure rise along one wavelength and stream function. A plug swidth is featured in the solutions. Via symbolic software (Mathematica), graphical plots are generated for the influence of Bingham plug flow width parameter, electrical Debye length and Helmholtz-Smoluchowski velocity (maximum electro-osmotic velocity) on the key hydrodynamic variables. This study reveals that blood flow rate accelerates with decreasing the plug width (i.e. viscoplastic nature of fluids) and also with increasing the Debye length parameter. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. The fluid mechanics of continuous flow electrophoresis

    Science.gov (United States)

    Saville, D. A.

    1990-01-01

    The overall objective is to establish theoretically and confirm experimentally the ultimate capabilities of continuous flow electrophoresis chambers operating in an environment essentially free of particle sedimentation and buoyancy. The efforts are devoted to: (1) studying the effects of particle concentration on sample conductivity and dielectric constant. The dielectric constant and conductivity were identified as playing crucial roles in the behavior of the sample and on the resolving power and throughput of continuous flow devices; and (2) improving the extant mathematical models to predict flow fields and particle trajectories in continuous flow electrophoresis. A dielectric spectrometer was designed and built to measure the complex dielectric constant of a colloidal dispersion as a function of frequency between 500 Hz and 200 kHz. The real part of the signal can be related to the sample's conductivity and the imaginary part to its dielectric constant. Measurements of the dielectric constants of several different dispersions disclosed that the dielectric constants of dilute systems of the sort encountered in particle electrophoresis are much larger than would be expected based on the extant theory. Experiments were carried out to show that, in many cases, this behavior is due to the presence of a filamentary structure of small hairs on the particle surface. A technique for producing electrokinetically ideal synthetic latex particles by heat treating was developed. Given the ubiquitous nature of hairy surfaces with both cells and synthetic particles, it was deemed necessary to develop a theory to explain their behavior. A theory for electrophoretic mobility of hairy particles was developed. Finally, the extant computer programs for predicting the structure of electro-osmotically driven flows were extended to encompass flow channels with variable wall mobilities.

  10. Single- and two-phase flow modeling for coupled neutronics / thermal-hydraulics transient analysis of advanced sodium-cooled fast reactors

    International Nuclear Information System (INIS)

    Chenu, A.

    2011-10-01

    Nuclear power is nowadays in the front rank as regards helping to meet the growing worldwide energy demand while avoiding an excessive increase in greenhouse gas emissions. However, the operating nuclear power plants are mainly thermal-neutron reactors and, as such, can not be maintained on the basis of the currently identified uranium resources beyond one century at the present consumption rate. Sustainability of nuclear power thus involves closure of the fuel cycle through breeding. With a uranium-based fuel, breeding can only be achieved using a fast-neutron reactor. Sodium-cooled fast reactor (SFR) technology benefits from 400 reactor-years of accumulated experience and is thus a prime candidate for the implementation of so-called Generation-IV nuclear energy systems. In this context, the safety demonstration of SFRs remains a major Research and Development related issue. The current research aims at the development of a computational tool for the in-depth understanding of SFR core behaviour during accidental transients, particularly those including boiling of the coolant. An accurate modelling of the core physics during such transients requires the coupling between 3D neutron kinetics and thermal-hydraulics in the core, to account for the strong interactions between the two-phase coolant flow and power variations caused by the sodium void effect. The present study is specifically focused upon models for the representation of sodium two-phase flow. The extension of the thermal-hydraulics TRACE code, previously limited to the simulation of single-phase sodium flow, has been carried out through the implementation of equations-of-state and closure relations specific to sodium. The different correlations have then been implemented as options. From the validation study carried out, it has been possible to recommend a set of models which provide satisfactory results, while considering annular flow as the dominant regime up to dryout and a smooth breakdown of the

  11. Development of a Reduced-Order Three-Dimensional Flow Model for Thermal Mixing and Stratification Simulation during Reactor Transients

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Rui

    2017-09-03

    Mixing, thermal-stratification, and mass transport phenomena in large pools or enclosures play major roles for the safety of reactor systems. Depending on the fidelity requirement and computational resources, various modeling methods, from the 0-D perfect mixing model to 3-D Computational Fluid Dynamics (CFD) models, are available. Each is associated with its own advantages and shortcomings. It is very desirable to develop an advanced and efficient thermal mixing and stratification modeling capability embedded in a modern system analysis code to improve the accuracy of reactor safety analyses and to reduce modeling uncertainties. An advanced system analysis tool, SAM, is being developed at Argonne National Laboratory for advanced non-LWR reactor safety analysis. While SAM is being developed as a system-level modeling and simulation tool, a reduced-order three-dimensional module is under development to model the multi-dimensional flow and thermal mixing and stratification in large enclosures of reactor systems. This paper provides an overview of the three-dimensional finite element flow model in SAM, including the governing equations, stabilization scheme, and solution methods. Additionally, several verification and validation tests are presented, including lid-driven cavity flow, natural convection inside a cavity, laminar flow in a channel of parallel plates. Based on the comparisons with the analytical solutions and experimental results, it is demonstrated that the developed 3-D fluid model can perform very well for a wide range of flow problems.

  12. Conceptualization of the predevelopment groundwater flow system and transient water-level responses in Yucca Flat, Nevada National Security Site, Nevada

    Science.gov (United States)

    Fenelon, Joseph M.; Sweetkind, Donald S.; Elliott, Peggy E.; Laczniak, Randell J.

    2012-01-01

    aquifer. Flow directions in the alluvial-volcanic aquifer are variable and are controlled by localized areas where small amounts of water can drain into the regional carbonate aquifer. These areas commonly are controlled by geologic structures, such as Yucca fault. Flow in the regional carbonate aquifer generally drains to the center of the basin; from there flow is to the south-southeast out of the study area toward downgradient discharge areas. Southward flow in the regional carbonate aquifer occurs in a prominent potentiometric trough that results from a faulted zone of enhanced permeability centered about Yucca fault. Vertical hydraulic gradients between the aquifer systems are downward throughout the study area; however, flow from the alluvial-volcanic aquifer into the underlying carbonate aquifer is believed to be minor because of the intervening confining unit. Transient water levels were identified and analyzed to understand hydraulic responses to stresses in Yucca Flat. Transient responses have only a minimal influence on the general predevelopment flow directions in the aquifers. The two primary anthropogenic stresses on the groundwater system since about 1950 are nuclear testing and pumping. Most of the potentiometric response in the aquifers to pumping or past nuclear testing is interim and localized. Persistent, long-lasting changes in hydraulic head caused by nuclear testing occur only in confining units where groundwater fluxes are negligible. A third stress on the groundwater system is natural recharge, which can cause minor, short- and long-term changes in water levels. Long-term hydrographs affected by natural recharge, grouped by similar trend, cluster in distinct areas of Yucca Flat and are controlled primarily by spatial differences in local recharge patterns.

  13. Transient flow processes in pipelines. Visualisation and calculation of cavitation in pipeline systems behind fast-closing control valves; Transiente Stroemungsvorgaenge in Rohrleitungen. Visualisierung und Berechnung von Kavitation in Rohrleitungssystemen hinter schnellschliessenden Regelklappen

    Energy Technology Data Exchange (ETDEWEB)

    Dudlik, A.; Schlueter, S. [Fraunhofer-Institut fuer Umwelt-, Sicherheits- und Energietechnik UMSICHT, Oberhausen (Germany); Prasser, H.M. [Forschungszentrum Rossendorf e.V. (FZR), Dresden (Germany)

    1997-12-01

    In this article, experimental results of the current BMBF research project are introduced. The transient pressure curves when closing a control valve quickly are measured and compared with the predictions of the project software. Flow visualisation shows that the computer model of the concentrated steam cavitation can be used in the application of the characterisation process. Due to the reduction in pressure in cavitating system, there is outgassing of air, which remains as dispersed phase in condensation and dampens the sudden condensation. For long periods of time with system pressures below the saturation partial pressures of the released gases, one must expect a reduced speed of wave propagation. [Deutsch] In diesem Beitrag werden Versuchsergebnisse des laufenden BMBF-Forschungsvorhabens vorgestellt. Es werden die transienten Druckverlaeufe beim Schnellschluss einer Regelklappe gemessen und mit den Vorhersagen der Projektsoftware verglichen. Die berechneten Druckspitzen liegen im Bereich der gemessenen Werte. Stroemungsvisualisierungen zeigen, dass das Rechenmodell der konzentrierten Dampfkavitation bei Anwendung des Charakteristikenverfahrens anwendbar ist. Es kommt durch die Druckabsenkung im kavitierenden System zur Ausgasung von Luft, die bei der Kondensation als disperse Phase verbleibt und die Kondensationsschlaege daempft. Fuer laengere Zeitperioden mit Systemdruecken unterhalb der Saettigungspartialdruecke der geloesten Gase muss mit einer verminderten Wellenausbreitungsgeschwindigkeit gerechnet werden. (orig.)

  14. HVDC-System-Interaction Assessment through Line-Flow Change-Distribution Factor and Transient-Stability Analysis at Planning Stage

    Directory of Open Access Journals (Sweden)

    Sungchul Hwang

    2016-12-01

    Full Text Available Many of the recent projects for new transmission line have considered the high-voltage direct current (HVDC system, owing to the many advantages of the direct current (DC system. The most noteworthy advantage is that a cable can serve as a substitute for the overhead transmission line in residential areas; therefore, the HVDC system application is increasing, and as the number of DC systems in the power system increases, the interaction assessment regarding the HVDC system gains importance. An index named multi-infeed interaction factor (MIIF is commonly used to estimate the interaction between power converters; however, the HVDC system is composed of two converters and a transmission line. The MIIF represents the interaction between the rectifiers and inverters, but not for the whole system. In this work, a method to assess the interaction of the whole system was therefore studied. To decide on the location of the new HVDC transmission system at the planning stage, in consideration of the interaction of the existing DC system, the line flow change distribution factor, according to the HVDC-transmission capacity change, was examined. Also, a power system transient -stability analysis was performed with different HVDC system locations, depending on the distribution factor. The simulation results indicate that when the factor is higher, two HVDC systems have a stronger interaction and are less stable in the transient state.

  15. Measurement of the filling height of transient two-phase surge flows in pipelines by means of electronics; Messung der Fuellhoehe von transienten Zweiphasenschwallstroemungen in Rohrleitungen mittels Ultraschall

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, B.; Rockstroh, M. [Technische Univ. Dresden (Germany). Inst. fuer Energiemaschinen und Maschinenlabor

    1997-12-01

    The aim of the ultrasonic measurements was the determination of the time course of the level of a transient surge flow with swirl and waves in partly filled roughly horizontally laid pipelines. The running time of the ultrasonic waves from the test head to the liquid surface and back was measured for this purpose. The course of the stress was recorded digitally and was evaluated with the aid of software. Waves, swirl, turbulence of flow and introduced test bodies in the flow caused typical echoes, which had to be taken into account in the evaluation. As the test head was fitted on the outside of the pipe (clamp-on technique), the pipe wall thickness and the speed of sound in the pipe wall had to be included in the calculation of filling height by means of a correction. [Deutsch] Ziel der Ultraschallmessungen war die Bestimmung des zeitlichen Verlaufes der Fuellhoehe einer transienten, drall- und wellenbehafteten Schwallstroemung in teilgefuellten, etwa horizontal verlegten Rohrleitungen. Hierzu wurde die Laufzeit der Ultraschallwellen vom Pruefkopf zur Fluessigkeitsoberflaeche und zurueck gemessen. Die Laufzeit der Ultraschallwellen wurde auf eine quasi-analog elektrische Spannung abgebildet. Der Spannungsverlauf wurde digital aufgezeichnet und softwaregestuetzt ausgewertet. Wellen, Drall, Stroemungsturbulenzen sowie eingebrachte Pruefkoerper in der Stroemung hatten typische Echoerscheinungen zur Folge, die bei der Auswertung zu beruecksichtigen waren. Da der Pruefkopf aussen am Rohr angebracht war (clamp-on-Technik), musste die Rohrwandstaerke und die Schallgeschwindigkeit in der Rohrwandung mittels eines Korrekturgliedes in die Fuellhoehenberechnung eingezogen werden. (orig.)

  16. Onset of slugging criterion based on singular points and stability analyses of transient one-dimensional two-phase flow equations of two-fluid model

    International Nuclear Information System (INIS)

    Sung, Chang Kyung; Chun, Moon Hyun

    1996-01-01

    A two-step approach has been used to obtain a new criterion for the onset of slug formation : (1) In the first step, a more general expression than the existing models for the onset of slug flow criterion has been derived from the analysis of singular points and neutral stability conditions of the transient one-dimensional two-phase flow equations of two-fluid model. (2) In the second step, introducing simplifications and incorporating a parameter into the general expression obtained in the first step to satisfy a number of physical conditions a priori specified, a new simple criterion for the onset of slug flow has been derived. Comparisons of the present model with existing models and experimental data show that the present model agree very closely with Taitel and Dukler's model and experimental data in horizontal pipes. In an inclined pipe (θ=50 deg ), however, the difference between the predictions of the present model and those of existing models is appreciably large and the present model gives the best agreement with Ohnuki et al.'s data. 17 refs., 5 figs., 1 tab. (author)

  17. Transient Droplet Behavior and Droplet Breakup during Bulk and Confined Shear Flow in Blends with One Viscoelastic Component: Experiments, Modelling and Simulations

    Science.gov (United States)

    Cardinaels, Ruth; Verhulst, Kristof; Renardy, Yuriko; Moldenaers, Paula

    2008-07-01

    The transient droplet deformation and droplet orientation after inception of shear, the shape relaxation after cessation of shear and droplet breakup during shear, are microscopically studied, both under bulk and confined conditions. The studied blends contain one viscoelastic Boger fluid phase. A counter rotating setup, based on a Paar Physica MCR300, is used for the droplet visualisation. For bulk shear flow, it is shown that the droplet deformation during startup of shear flow and the shape relaxation after cessation of shear flow are hardly influenced by droplet viscoelasticity, even at moderate to high capillary and Deborah numbers. The effects of droplet viscoelasticity only become visible close to the critical conditions and a novel break-up mechanism is observed. Matrix viscoelasticity has a more pronounced effect, causing overshoots in the deformation and significantly inhibiting relaxation. However, different applied capillary numbers prior to cessation of shear flow, with the Deborah number fixed, still result in a single master curve for shape retraction, as in fully Newtonian systems. The long tail in the droplet relaxation can be qualitatively described with a phenomenological model for droplet deformation, when using a 5-mode Giesekus model for the fluid rheology. It is found that the shear flow history significantly affects the droplet shape evolution and the breakup process in blends with one viscoelastic component. Confining a droplet between two plates accelerates the droplet deformation kinetics, similar to fully Newtonian systems. However, the increased droplet deformation, due to wall effects, causes the steady state to be reached at a later instant in time. Droplet relaxation is less sensitive to confinement, leading to slower relaxation kinetics only for highly confined droplets. For the blend with a viscoelastic droplet, a non-monotonous trend is found for the critical capillary number as a function of the confinement ratio. Finally

  18. Transient Droplet Behavior and Droplet Breakup during Bulk and Confined Shear Flow in Blends with One Viscoelastic Component: Experiments, Modelling and Simulations

    International Nuclear Information System (INIS)

    Cardinaels, Ruth; Verhulst, Kristof; Moldenaers, Paula; Renardy, Yuriko

    2008-01-01

    The transient droplet deformation and droplet orientation after inception of shear, the shape relaxation after cessation of shear and droplet breakup during shear, are microscopically studied, both under bulk and confined conditions. The studied blends contain one viscoelastic Boger fluid phase. A counter rotating setup, based on a Paar Physica MCR300, is used for the droplet visualisation. For bulk shear flow, it is shown that the droplet deformation during startup of shear flow and the shape relaxation after cessation of shear flow are hardly influenced by droplet viscoelasticity, even at moderate to high capillary and Deborah numbers. The effects of droplet viscoelasticity only become visible close to the critical conditions and a novel break-up mechanism is observed. Matrix viscoelasticity has a more pronounced effect, causing overshoots in the deformation and significantly inhibiting relaxation. However, different applied capillary numbers prior to cessation of shear flow, with the Deborah number fixed, still result in a single master curve for shape retraction, as in fully Newtonian systems. The long tail in the droplet relaxation can be qualitatively described with a phenomenological model for droplet deformation, when using a 5-mode Giesekus model for the fluid rheology. It is found that the shear flow history significantly affects the droplet shape evolution and the breakup process in blends with one viscoelastic component. Confining a droplet between two plates accelerates the droplet deformation kinetics, similar to fully Newtonian systems. However, the increased droplet deformation, due to wall effects, causes the steady state to be reached at a later instant in time. Droplet relaxation is less sensitive to confinement, leading to slower relaxation kinetics only for highly confined droplets. For the blend with a viscoelastic droplet, a non-monotonous trend is found for the critical capillary number as a function of the confinement ratio. Finally

  19. Regional cerebral blood flow and metabolism in patients with transient global amnesia. A study using SPECT and {sup 1}H-MRS

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Tetsuya; Hirata, Koichi; Tatsumoto, Muneto; Yamazaki, Kaoru [Dokkyo Univ., Tochigi (Japan). School of Medicine; Sato, Toshihiko

    1997-06-01

    In 13 patients with transient global amnesia (TGA), we studied the clinical course and changes over time by means of imaging techniques such as SPECT. MRI, and proton MR spectroscopy ({sup 1}H-MRS). In the case of SPECT, a cerebral blood flow decrease at the time center of the temporal lobe persisted at least for more than one month. In many patients, no abnormal signs were found on MRI. Despite the presence of intracranial impairment of energy metabolism, no evidence of cerebral ischemia was obtained using {sup 1}H-MRS at the acute and subacute stages. There were thus discrepancies between the symptoms and the findings of SPECT as well as the findings of {sup 1}H-MRS. These data suggest that TGA may not necessarily be caused by cerebra1 ischemia. (author)

  20. Evolution of cerebral blood flow between the acute stage and one month after a global transient amnesia: a study of 18 patients

    International Nuclear Information System (INIS)

    Philippon, B.; Houzard, C.; Cinotti, L.; Croisile, B.

    2001-01-01

    We studied 18 patients within 24 hours of an idiopathic transient global amnesia and one month later using 133 Xe et 99m Tc-HMPAO for CBF measurements. Absolute hemispheric CBF obtained with the 133 Xe were initially: (right) = 46.9 ml/mn/100 g (s.d 6.6) and (left) = 47.9 (s.d 6.8). One month later, a significant increase of the right hemispheric CBF occurred (52.0 ± 6.9). Accordingly, absolute CBF increased bilaterally in the cerebellar and temporal regions. Local relative cerebral blood flow ( 99m Tc-HMPAO) allowed to reinforce these findings with increased resolution. They can also provide quantitative values thanks to the 133 Xe calibration. (authors)

  1. Regional cerebral blood flow and metabolism in patients with transient global amnesia. A study using SPECT and 1H-MRS

    International Nuclear Information System (INIS)

    Ishihara, Tetsuya; Hirata, Koichi; Tatsumoto, Muneto; Yamazaki, Kaoru; Sato, Toshihiko.

    1997-01-01

    In 13 patients with transient global amnesia (TGA), we studied the clinical course and changes over time by means of imaging techniques such as SPECT. MRI, and proton MR spectroscopy ( 1 H-MRS). In the case of SPECT, a cerebral blood flow decrease at the time center of the temporal lobe persisted at least for more than one month. In many patients, no abnormal signs were found on MRI. Despite the presence of intracranial impairment of energy metabolism, no evidence of cerebral ischemia was obtained using 1 H-MRS at the acute and subacute stages. There were thus discrepancies between the symptoms and the findings of SPECT as well as the findings of 1 H-MRS. These data suggest that TGA may not necessarily be caused by cerebra1 ischemia. (author)

  2. Regional cerebral blood flow before and after vascular surgery in patients with transient ischemic attacks with 133-xenon inhalation tomography

    DEFF Research Database (Denmark)

    Vorstrup, S; Hemmingsen, Ralf; Lindewald, H

    1982-01-01

    with no abnormality on the CT-scan. The abnormal blood flow pattern was found to be unchanged after clinically successful reconstructive vascular surgery. This suggests the presence of irreversible ischemic tissue damage without gross emollition (incomplete infarction). It is concluded, that TIAs are often harmful...

  3. Transient increase in nuchal translucency thickness and reversed end-diastolic ductus venosus flow in a fetus with trisomy 18

    NARCIS (Netherlands)

    Huisman, T. W.; Bilardo, C. M.

    1997-01-01

    In a twin pregnancy discordant for trisomy 18, the affected fetus at 13 weeks' gestation had an increased nuchal translucency thickness and reversed end-diastolic ductus venosus flow. At 20 weeks' gestation there was no nuchal edema and Doppler study of the central venous vessels demonstrated normal

  4. A Non-local Model for Transient Moisture Flow in Unsaturated Soils Based on the Peridynamic Theory

    Science.gov (United States)

    Jabakhanji, R.; Mohtar, R. H.

    2012-12-01

    A non-local, gradient free, formulation of the porous media flow problem in unsaturated soils was derived. It parallels the peridynamic theory, a non-local reformulation of solid mechanics presented by Silling. In the proposed model, the evolution of the state of a material point is driven by pairwise interactions with other points across finite distances. Flow and changes in moisture are the result of these interactions. Instead of featuring local gradients, the proposed model expresses the flow as a functional integral of the hydraulic potential field. The absence of spatial gradients, undefined at or on discontinuities, makes the model a good candidate for flow simulations in fractured soils. It also lends itself to coupling with peridynamic mechanical models for simulating crack formation triggered by shrinkage and swelling, and assessing their potential impact on a wide range of processes, such as infiltration, contaminant transport, slope stability and integrity of clay barriers. A description of the concept and an outline of the derivation and numerical implementation are presented. Simulation results of infiltration and drainage for 1D, single and two-layers soil columns, for three different soil types are also presented. The same simulations are repeated using HYDRUS-1D, a computer model using the classic local flow equation. We show that the proposed non-local formulation successfully reproduces the results from HYDRUS-1D. S.A. Silling, "Reformulation of Elasticity Theory for Discontinuities and Long-range Forces," Journal of the Mechanics and Physics of Solids 48, no. 1 (January 2000): 175-209. J. Simunek, M. Sejna, and M.T. Van Genuchten, "The HYDRUS-1D Software Package for Simulating the One-dimensional Movement of Water, Heat, and Multiple Solutes in Variably-saturated Media," University of California, Riverside, Research Reports 240 (2005).

  5. Electromagnetohydrodynamic flow of blood and heat transfer in a capillary with thermal radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, A. [Department of Mathematics, Jadavpur University, Kolkata 700032 (India); Shit, G.C., E-mail: gopal_iitkgp@yahoo.co.in [Department of Mathematics, Jadavpur University, Kolkata 700032 (India); Institute of Mathematical Sciences, Chennai 600113 (India)

    2015-03-15

    This paper presents a comprehensive theoretical study on heat transfer characteristics together with fully developed electromagnetohydrodynamic flow of blood through a capillary, having electrokinetic effects by considering the constant heat flux at the wall. The effect of thermal radiation and velocity slip condition have been taken into account. A rigorous mathematical model for describing Joule heating in electro-osmotic flow of blood including the Poisson–Boltzmann equation, the momentum equation and the energy equation is developed. The alterations in the thermal transport phenomenon, induced by the variation of imposed electromagnetic effects, are thoroughly explained through an elegant mathematical formalism. Results presented here pertain to the case where the height of the capillary is much greater than the thickness of electrical double layer comprising the stern and diffuse layers. The essential features of the electromagnetohydrodynamic flow of blood and associated heat transfer characteristics through capillary are clearly highlighted by the variations in the non-dimensional parameters for velocity profile, temperature profile and the Nusselt number. The study reveals that the temperature of blood can be controlled by regulating Joule heating parameter. - Highlights: • Electromagnetohydrodynamic flow of blood in capillary is studied. • Potential electric field is applied for driving elecroosmotic flow of blood. • Effect of thermal radiation, Joule heating and velocity slip is investigated. • Thermal radiation bears the significant change in the temperature field.

  6. VARR2 VARRLXSG, 2-D Transient Fluid Flow and Heat Transfer in X-Y and Cylindrical Geometry

    International Nuclear Information System (INIS)

    Cook, J. L.; Nakayama, P. I.; Andreychek, T.

    1980-01-01

    1 - Description of problem or function: VARR2 is a two-dimensional transient slightly-compressible fluid dynamics program. It solves the complete unsteady Navier-Stokes equation, the energy equation, and the continuity equation in either Cartesian or axisymmetric cylindrical geometry. Slight density variations are accounted for by use of the Boussinesq approximation, which couples the energy and momentum equations. At a cell face, the normal velocity component may be inward, outward, or zero; the tangential velocity component may specify free slip, no slip, or no slip with a turbulent velocity profile. For heat transfer problems, adiabatic or constant heat flux boundary conditions can be specified. By specifying the totality of cell-face boundary conditions in a self-consistent manner, the user can specify a wide spectrum of overall boundary conditions; for example, those called rigid, continuative, periodic, inflow/outflow, or derived. 2 - Method of solution: The governing differential equations are replaced by finite difference equations of explicit type and solved over a region of fixed rectangular cells by using the simplified marker and cell technique (SMAC) of Amsden and Harlow. The continuity equation is solved through a successive over- relaxation (SOR) iterative process on a Poisson equation for pressure. 3 - Restrictions on the complexity of the problem: With current dimensioning, the maximum number of cells is about 1600; roughly a 40 x 40 mesh. The problem geometry must be reasonably approximated by a two-dimensional net of rectangular cells, either in Cartesian geometry or transformed from axisymmetric cylindrical geometry. Interior obstacles are allowed. The working fluid may be specified as either sodium or water if the built-in material property coefficients are used. Otherwise, the properties of the working fluid may be entered as part of the problem input

  7. Transient Calibration of a Variably-Saturated Groundwater Flow Model By Iterative Ensemble Smoothering: Synthetic Case and Application to the Flow Induced During Shaft Excavation and Operation of the Bure Underground Research Laboratory

    Science.gov (United States)

    Lam, D. T.; Kerrou, J.; Benabderrahmane, H.; Perrochet, P.

    2017-12-01

    The calibration of groundwater flow models in transient state can be motivated by the expected improved characterization of the aquifer hydraulic properties, especially when supported by a rich transient dataset. In the prospect of setting up a calibration strategy for a variably-saturated transient groundwater flow model of the area around the ANDRA's Bure Underground Research Laboratory, we wish to take advantage of the long hydraulic head and flowrate time series collected near and at the access shafts in order to help inform the model hydraulic parameters. A promising inverse approach for such high-dimensional nonlinear model, and which applicability has been illustrated more extensively in other scientific fields, could be an iterative ensemble smoother algorithm initially developed for a reservoir engineering problem. Furthermore, the ensemble-based stochastic framework will allow to address to some extent the uncertainty of the calibration for a subsequent analysis of a flow process dependent prediction. By assimilating the available data in one single step, this method iteratively updates each member of an initial ensemble of stochastic realizations of parameters until the minimization of an objective function. However, as it is well known for ensemble-based Kalman methods, this correction computed from approximations of covariance matrices is most efficient when the ensemble realizations are multi-Gaussian. As shown by the comparison of the updated ensemble mean obtained for our simplified synthetic model of 2D vertical flow by using either multi-Gaussian or multipoint simulations of parameters, the ensemble smoother fails to preserve the initial connectivity of the facies and the parameter bimodal distribution. Given the geological structures depicted by the multi-layered geological model built for the real case, our goal is to find how to still best leverage the performance of the ensemble smoother while using an initial ensemble of conditional multi

  8. Thermal transient anemometer

    Science.gov (United States)

    Bailey, James L.; Vresk, Josip

    1989-01-01

    A thermal transient anemometer having a thermocouple probe which is utilized to measure the change in temperature over a period of time to provide a measure of fluid flow velocity. The thermocouple probe is located in the fluid flow path and pulsed to heat or cool the probe. The cooling of the heated probe or the heating of the cooled probe from the fluid flow over a period of time is measured to determine the fluid flow velocity. The probe is desired to be locally heated near the tip to increase the efficiency of devices incorporating the probe.

  9. Transport of solutes under transient flow conditions – A case study – Yamuna river sub basin (Kosi Kalan to Agra

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-09-01

    Full Text Available The imbalance between incoming and outgoing salt causes salinization of soils and sub-soils that result in increasing the salinity of stream-flows and agriculture land. This salinization is a serious environmental hazard particularly in semi-arid and arid lands. In order to estimate the magnitude of the hazard posed by salinity, it is important to understand and identify the processes that control salt movement from the soil surface through the root zone to the ground water and stream flows. In the present study, Yamuna sub-basin (both sides of Gokul dam site has been selected which has two distinct climatic zones, sub-humid (upstream of Mathura and semi-arid region (downstream of Mathura. In the upstream, both surface and ground waters are used for irrigation, whereas in the downstream mostly groundwater is used. Both soils and ground waters are more saline in downstream parts of the study area. In this study we characterized the soil salinity and groundwater quality in both areas. An attempt is also made to model the distribution of potassium concentration in the soil profile in response to varying irrigation conditions using the Soil-Water Infiltration and Movement (SWIM model. Fair agreement was obtained between predicted and measured results indicating the applicability of the model.

  10. Transient stability and control of wind turbine generation based on Hamiltonian surface shaping and power flow control

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, David G.; Robinett, Rush D. III [Sandia National Laboratories, Albuquerque, NM (United States). Energy, Resources and Systems Analysis Center

    2010-07-01

    The swing equations for renewable generators connected to the grid are developed and a simple wind turbine with UPFC is used as an example. The swing equations for renewable generator are formulated as a natural Hamiltonian system with externally applied non-conservative forces. A two-step process referred to as Hamiltonian Surface Shaping and Power Flow Control (HSSPFC) is used to analyze and design feedback controllers for the renewable generators system. This formulation extends previous results on the analytical verification of the Potential Energy Boundary Surface (PEBS) method to nonlinear control analysis and design and justifies the decomposition of the system into conservative and nonconservative systems to enable a two-step, serial analysis and design procedure. This paper presents the analysis and numerical simulation results for a nonlinear control design example that includes the One-Machine Infinite Bus (OMIB) system with a Unified Power Flow Control (UPEC) and applied to a simplified wind turbine generator. The needed power and energy storage/charging responses are also determined. (orig.)

  11. Transient electro-magneto-hydrodynamic two-phase blood flow and thermal transport through a capillary vessel.

    Science.gov (United States)

    Mirza, I A; Abdulhameed, M; Vieru, D; Shafie, S

    2016-12-01

    Therapies with magnetic/electromagnetic field are employed to relieve pains or, to accelerate flow of blood-particles, particularly during the surgery. In this paper, a theoretical study of the blood flow along with particles suspension through capillary was made by the electro-magneto-hydrodynamic approach. Analytical solutions to the non-dimensional blood velocity and non-dimensional particles velocity are obtained by means of the Laplace transform with respect to the time variable and the finite Hankel transform with respect to the radial coordinate. The study of thermally transfer characteristics is based on the energy equation for two-phase thermal transport of blood and particles suspension with viscous dissipation, the volumetric heat generation due to Joule heating effect and electromagnetic couple effect. The solution of the nonlinear heat transfer problem is derived by using the velocity field and the integral transform method. The influence of dimensionless system parameters like the electrokinetic width, the Hartman number, Prandtl number, the coefficient of heat generation due to Joule heating and Eckert number on the velocity and temperature fields was studied using the Mathcad software. Results are presented by graphical illustrations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Experimental and analytical study of loss-of-flow transients in EBR-II occurring at decay power levels

    International Nuclear Information System (INIS)

    Chang, L.K.; Mohr, D.; Feldman, E.E.; Betten, P.R.; Planchon, H.P.

    1986-01-01

    One of the major objectives of the EBR-II Shutdown Heat Removal Test (SHRT) program is to study the ability of natural convection to remove decay heat from the EBR-II plant under variety of conditions. This study provides additional understanding and insight relative to operational reactor reliability and safety of the EBR-II plant and is also generally applicable to the design of future fast breeder reactors. Furthermore, data obtained from natural convective tests can be used to show that unprotected (no scram) loss-of-flow (LOF) tests can be safely conducted in EBR-II and to validate simulation codes used in the design and safety analysis of reactor plants. Two well-instrumented subassemblies were installed in EBR-II core to measure temperatures and flows during the tests. One of the subassemblies, XX09, is fueled with typical EBR-II driver fuel elements, and the other, XX10, is an unfueled subassembly containing only stainless steel rods which thermal-hydraulically simulates a blanket subassembly. Both subassemblies are located in the driver region and occupy control rod positions. There is also extensive instrumentation throughout the reactor and the balance of the plant; and a data acquisition system collects data from a few hundred instruments and records the digital results on magnetic tape at 0.5 sec. interval

  13. Hot-wire air flow meter for gasoline fuel-injection system. Calculation of air mass in cylinder during transient condition; Gasoline funsha system yo no netsusenshiki kuki ryuryokei. Kato untenji no cylinder juten kukiryo no keisan

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Y. [Hitachi Car Engineering, Ltd., Tokyo (Japan); Nishimura, Y.; Osuga, M.; Yamauchi, T. [Hitachi, Ltd., Tokyo (Japan)

    1997-10-01

    Air flow characteristics of hot-wire air flow meters for gasoline fuel-injection systems with supercharging and exhaust gas recycle during transient conditions were investigated to analyze a simple method for calculating air mass in cylinder. It was clarified that the air mass in cylinder could be calculated by compensating for the change of air mass in intake system by using aerodynamic models of intake system. 3 refs., 6 figs., 1 tab.

  14. Transient methods to characterize flows and mass transfer in a packed column by tracers; Methodes transitoires de caracterisation des ecoulements et du transfert de masse dans une colonne a garnissage a l'aide de traceurs

    Energy Technology Data Exchange (ETDEWEB)

    Perrin, S.

    1998-06-11

    The aim of this study is to propose a packed column characterization method in the form of phases flows and mass transfer model, in which the parameters are estimated by transient technique. After a bibliographic study a model is performed and validated. It allows efficiency and precision in the parameters choice. Two tracer techniques have been implemented: they show interesting possibilities of flow diagnosis. (A.L.B.)

  15. Summary and evaluation of transient test data on extended fuel motion resulting from unprotected loss of flow

    Energy Technology Data Exchange (ETDEWEB)

    Dickerman, C E

    1977-06-01

    Experimental data on fuel failure and its consequences are used to provide predictions of the extended fuel motion that would occur after a hypothetical core-disruptive loss-of-flow accident without scram in the Fast Test Reactor. These data indicate the existence of fuel-dispersal mechanisms, slow collapse of fresh fuel, resistance to collapse of irradiated fuel, the absence of accelerated collapse mechanisms (such as cladding-coolant vapor ''explosions''), and the fact that real LMFBR conditions inhibit rapid sodium-vaporization events. These data indicate that severely damaged subassemblies will not be coolable in situ by returning sodium after the accident, because of steel and fuel blockages, and suggest that the severely damaged, melted fuel will eventually disperse upward under the influence of vapor generated by decay heating.

  16. A Conditionally Stable Scheme for a Transient Flow of a Non-Newtonian Fluid Saturating a Porous Medium

    KAUST Repository

    El-Amin, Mohamed

    2012-06-02

    The problem of thermal dispersion effects on unsteady free convection from an isothermal horizontal circular cylinder to a non-Newtonian fluid saturating a porous medium is examined numerically. The Darcy-Brinkman-Forchheimer model is employed to describe the flow field. The thermal diffusivity coefficient has been assumed to be the sum of the molecular diffusivity and the dynamic diffusivity due to mechanical dispersion. The simultaneous development of the momentum and thermal boundary layers are obtained by using finite difference method. The stability conditions are determined for each difference equation. Using an explicit finite difference scheme, solutions at each time-step have been found and then stepped forward in time until reaching steady state solution. Velocity and temperature profiles are shown graphically. It is found that as time approaches infinity, the values of friction factor and heat transfer coefficient approach the steady state values.

  17. Investigations for the transient behaviour of the accumulator's discharge flow in pressurized water reactors in consideration of dynamic heat and mass transfer processes. Final report

    International Nuclear Information System (INIS)

    Alt, S.; Gocht, U.; Lischke, W.; Schefter, S.

    2001-09-01

    Within the scope of German reactor safety research the thermal-hydraulic behaviour in accumulators was investigated experimentally and analytically for transient injection. The paper includes the description of two test facilities used for separate effect experiments for the discharge flow of accumulators. Results derived from experiments at a glass facility show the dependency of the nitrogen release processes in the water on the depressurization rate during negative pressure transients and a delay of release. This release delay caused oversaturated solutions and this effect has to be taken into account for the modelling of accumulators. It was not observed coalescence of nitrogen bubbles during rising but the appearance of humid nitrogen above the liquid level. At the test facility TRACEI separate effect experiments were carried out for the investigation of the heat and mass transfer to the nitrogen cushion, the release of nitrogen out of saturated pressurized water and the multidimensional distribution of the gas temperature. The measured data in the nitrogen cushion show different conditions of humid nitrogen such as unsaturated and saturated humid nitrogen, the occurrence of water droplets in terms of fog and frozen fog. Intensive distributions of temperature and humidity above the liquid level were detected during fast pressure gradients, hence high depressurization rates. Post test calculations were accomplished with the ATHLET-Code Mod. 1.2 Cycle B for selected TRACEI separate effect experiments. The comparison of calculated results and experimental data shows well calculated liquid level decreasing and a good agreement of the pressure transient even if the friction pressure loss coefficients of the connection pipe between the accumulator simulator and the venting vessel were adapted. Deviations between simulations and experiments arised in calculating the cushion gas temperature. In order to improve the simulation quality it was suggested to calculate the

  18. Numerical Investigation of 3-D Transient Combusting Flow in a 1.2MWth Pilot Power Plant

    Science.gov (United States)

    Nikolopoulos, A.; Rampldls, I.; Nlkelopoules, N.; Grammells, P.; Kakaras, E.

    As industrial Circulating Fluidized bed Combustors (CFBCs) tend to be scaled up, numerous design and operating problems emerge. At the same time uncertainties which concern hydrodynamics, combustion and pollutants formation mechanisms, come in to sight. Along with experience, CFD analysis can play crucial role providing further insight on the complex multiphase combusting flow occurring in CFBCs. This work aims to present a methodology for CFBCs comprehensive modeling, taking into consideration the coupling of hydrodynamics — heat transfer — chemical phenomena that take place in the bed. A combination of acceptable accuracy with high computational efficiency was also an objective. For this purpose, a simple combustion mechanism was integrated in an isothermal model and applied on a 1.2 MWth pilot plant. In this comprehensive model gas, inert-material and fuel are taken into consideration, as three discrete, pure eulerian phases. Solids inventory in the riser as well as temperature of the bed were predicted with satisfactory accuracy. Moreover, major chemical components as O2 and CO2 concentrations were predicted along the bed with acceptable accuracy. Concluding, the developed CFD model is capable of efficiently modeling a CFBC. However in order to further increase total accuracy, the need for improved closure equations for the set ofPartial Differential Equations solved was made obvious. Finally, the computational cost for such modeling was found extremely high but not prohibitive for large scale CFBC simulations.

  19. Transient analyzer

    International Nuclear Information System (INIS)

    Muir, M.D.

    1975-01-01

    The design and design philosophy of a high performance, extremely versatile transient analyzer is described. This sub-system was designed to be controlled through the data acquisition computer system which allows hands off operation. Thus it may be placed on the experiment side of the high voltage safety break between the experimental device and the control room. This analyzer provides control features which are extremely useful for data acquisition from PPPL diagnostics. These include dynamic sample rate changing, which may be intermixed with multiple post trigger operations with variable length blocks using normal, peak to peak or integrate modes. Included in the discussion are general remarks on the advantages of adding intelligence to transient analyzers, a detailed description of the characteristics of the PPPL transient analyzer, a description of the hardware, firmware, control language and operation of the PPPL transient analyzer, and general remarks on future trends in this type of instrumentation both at PPPL and in general

  20. Field-Effect Modulated Electro-Osmotic Pumps for High Precision Colloid Thrusters, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The ability to precisely control the position of satellites is a critical enabling technology for space missions involving interferometric arrays. One proposed...

  1. Effects of some factors on electro-osmotic dewatering of Laterite ...

    African Journals Online (AJOL)

    ... effect on the EO process. The general effects were same for the two soil samples, but the rate of the effect varied, which implied that EO dewatering was site dependent. It was concluded that EO dewatering was a viable option for dewatering of tropical laterite. Keywords: Electro-osmosis, Soil Dewatering, Tropical Laterite, ...

  2. Moisture Control Using Intelligent Single Well Electro-osmotic Dewatering Systems

    Science.gov (United States)

    2010-02-01

    Technology Demonstrations at Army Installations BUILDING STRONG® Test Site Emperor Hirohito Air Raid Bunker  National historic site  The structure...Emperor Hirohito Air Raid Bunker Emperor Hirohito Air Raid Bunker Layout BUILDING STRONG® Moisture Problem  Obvious moisture infiltration

  3. Demonstration of Electro-Osmotic Pulse Technology for Groundwater Intrusion Control in Concrete Structures

    National Research Council Canada - National Science Library

    Hock, Vincent

    1998-01-01

    ...") can cause serious damage that is expensive to correct. In older buildings, such as those common on U.S. Army installations, severe damp-basement problems call for immediate action to mitigate water damage...

  4. In situ electro-osmotic cleanup of tar contaminated soil—Removal of polycyclic aromatic hydrocarbons

    KAUST Repository

    Lima, Ana T.

    2012-12-01

    An in situ electro-osmosis experiment was set up in a tar contaminated clay soil in Olst, the Netherlands, at the site of a former asphalt factory. The main goal of this experiment was to remove polycyclic aromatic hydrocarbons (PAHs) from the contaminated clay layer by applying an electric gradient of 12 V m-1 across the soil over an electrode distance of 1 m. With the movement of water by electro-osmosis and the addition of a non-ionic surfactant (Tween 80), the non-polar PAHs were dragged along by convection and removed from the fine soil fraction. Soil samples were taken at the start and after 159 days at the end of the experiment. Water at the electrode wells was sampled regularly during the course of the experiment. The results reflect the heterogeneity of the soil characteristics and show the PAH concentrations within the experimental set up. After first having been released into the anolyte solution due to extraction by Tween 80 and subsequent diffusion, PAH concentrations increased significantly in the electrode reservoirs at the cathode side after 90 days of experiment. Although more detailed statistical analysis is necessary to quantify the efficiency of the remediation, it can be concluded that the use of electro-osmosis together with a non-ionic surfactant is a feasible technique to mobilize non-polar organic contaminants in clayey soils. Crown Copyright © 2011 Published by Elsevier Ltd. All rights reserved.

  5. Feasibility of electro-osmotic belt filter dewatering technology at pilot scale

    CSIR Research Space (South Africa)

    Snyman, HG

    2000-01-01

    Full Text Available , the feasibility of the technology was tested at pilot scale using waste activated-, anaerobically digested- and dissolved air flotation sludge. The parameters which were investigated include the applied voltage, polyelectrolyte usage and sludge feed rate. Applied...

  6. Color Doppler imaging of the ophthalmic artery blood flow spectra of patients who have had a transient ischemic attack. Correlations with generalized iris transluminance and pseudoexfoliation syndrome.

    Science.gov (United States)

    Repo, L P; Suhonen, M T; Teräsvirta, M E; Koivisto, K J

    1995-08-01

    To study the interrelations among pseudoexfoliation syndrome (PXS), abnormal iris transluminance, and ophthalmic artery blood flow in a controlled study. Ultrasonographic examination using color Doppler imaging (CDI) was performed on the ophthalmic arteries of 46 unselected patients (92 eyes) who have had at least one transient ischemic attack (TIA) and on 32 healthy subjects (64 eyes). The authors recorded the peak systolic and end diastolic velocities and determined the resistivity indices. Iris transillumination photographs were evaluated by two ophthalmologists in a blind trial to show the presence of abnormal iris transluminance of these eyes. Biomicroscopic examination was performed to show the presence of PXS. The frequency of abnormal iris transluminance in the whole group of patients who had had a TIA and in control subjects was 63% and 28%, respectively (P iris transluminance and healthy subjects without transluminance was statistically significant (P iris transluminance. The exceptionally high frequency of PXS in the eyes of patients who had had a TIA with positive iris transluminance suggests pathologic changes in the blood supply of PXS eyes. High values of resistivity indices for the ophthalmic arteries of these eyes suggest that disturbances in the ciliary circulation may be the possible cause of these changes.

  7. A three-field model of transient 3D multiphase, three-component flow for the computer code IV A3. Pt. 1

    International Nuclear Information System (INIS)

    Kolev, N.I.

    1991-12-01

    This work contains description of the physical and mathematical basis on which the IVA3 computer code relies. After describing the state of the art of the 3D modeling for transient multiphase flows, the model assumptions and the modeling technique used in IVA3 are described. Starting with the principles of conservation of mass, momentum, and energy, the non averaged conservation equations are derived for each of the velocity fields which consist of different isothermal components. Thereafter averaging is applied and the working form of the system of 21 partial differential equations is derived. Special attention is paid to the strict consistence of the modeling technique used in IVA3 with the second principle of thermodynamics. The entropy concept used is derived starting with the unaveraged conservation equations and subsequent averaging. The source terms of the entropy production are carefully defined and the final form of the averaged entropy equation is given ready for direct practical applications. The idea of strong analytical thermodynamic coupling between pressure field and changes of the other thermodynamic properties, which is used for the first time in 3D multi fluid modeling, is presented in detail. After obtaining the working form of the conservation equations, the discretization procedure and the reduction to algebraic problems is presented. The mathematical solution method together with some information about the architecture of IVA3 including the local momentum decoupling and accuracy control is presented too. (orig./GL) [de

  8. Assessment of Effectiveness of Geologic Isolation Systems. Variable thickness transient ground-water flow model. Volume 2. Users' manual

    Energy Technology Data Exchange (ETDEWEB)

    Reisenauer, A.E.

    1979-12-01

    A system of computer codes to aid in the preparation and evaluation of ground-water model input, as well as in the computer codes and auxillary programs developed and adapted for use in modeling major ground-water aquifers is described. The ground-water model is interactive, rather than a batch-type model. Interactive models have been demonstrated to be superior to batch in the ground-water field. For example, looking through reams of numerical lists can be avoided with the much superior graphical output forms or summary type numerical output. The system of computer codes permits the flexibility to develop rapidly the model-required data files from engineering data and geologic maps, as well as efficiently manipulating the voluminous data generated. Central to these codes is the Ground-water Model, which given the boundary value problem, produces either the steady-state or transient time plane solutions. A sizeable part of the codes available provide rapid evaluation of the results. Besides contouring the new water potentials, the model allows graphical review of streamlines of flow, travel times, and detailed comparisons of surfaces or points at designated wells. Use of the graphics scopes provide immediate, but temporary displays which can be used for evaluation of input and output and which can be reproduced easily on hard copy devices, such as a line printer, Calcomp plotter and image photographs.

  9. Dynamic simulations of under-rib convection-driven flow-field configurations and comparison with experiment in polymer electrolyte membrane fuel cells

    Science.gov (United States)

    Duy, Vinh Nguyen; Lee, Jungkoo; Kim, Kyungcheol; Ahn, Jiwoong; Park, Seongho; Kim, Taeeun; Kim, Hyung-Man

    2015-10-01

    The under-rib convection-driven flow-field design for the uniform distribution of reacting gas and the generation of produced water generates broad scientific interest, especially among those who study the performance of polymer electrolyte membrane fuel cells (PEMFCs). In this study, we simulate the effects of an under-rib convection-driven serpentine flow-field with sub-channel and by-pass (SFFSB) and a conventional advanced serpentine flow-field (CASFF) on single cell performance, and we compare the simulation results with experimental measurements. In the under-rib convection-driven flow-field configuration with SFFSB, the pressure drop is decreased because of the greater cross-sectional area for gas flow, and the decreased pressure drop results in the reduction of the parasitic loss. The anode liquid water mass fraction increases with increasing channel height because of increased back diffusion, while the cathode liquid water mass fraction does not depend upon the sub-channels but is ascribed mainly to the electro-osmotic drag. Simulation results verify that the maximum current and the power densities of the SFFSB are increased by 18.85% and 23.74%, respectively, due to the promotion of under-rib convection. The findings in this work may enable the optimization of the design of under-rib convection-driven flow-fields for efficient PEMFCs.

  10. Three-Dimensional Transport Modeling for Proton Exchange Membrane(PEM Fuel Cell with Micro Parallel Flow Field

    Directory of Open Access Journals (Sweden)

    Sang Soon Hwang

    2008-03-01

    Full Text Available Modeling and simulation for heat and mass transport in micro channel are beingused extensively in researches and industrial applications to gain better understanding of thefundamental processes and to optimize fuel cell designs before building a prototype forengineering application. In this study, we used a single-phase, fully three dimensionalsimulation model for PEMFC that can deal with both anode and cathode flow field forexamining the micro flow channel with electrochemical reaction. The results show thathydrogen and oxygen were solely supplied to the membrane by diffusion mechanism ratherthan convection transport, and the higher pressure drop at cathode side is thought to becaused by higher flow rate of oxygen at cathode. And it is found that the amount of water incathode channel was determined by water formation due to electrochemical reaction pluselectro-osmotic mass flux directing toward the cathode side. And it is very important tomodel the back diffusion and electro-osmotic mass flux accurately since the two flux wasclosely correlated each other and greatly influenced for determination of ionic conductivityof the membrane which directly affects the performance of fuel cell.

  11. Three-Dimensional Transport Modeling for Proton Exchange Membrane(PEM) Fuel Cell with Micro Parallel Flow Field.

    Science.gov (United States)

    Lee, Pil Hyong; Han, Sang Seok; Hwang, Sang Soon

    2008-03-03

    Modeling and simulation for heat and mass transport in micro channel are beingused extensively in researches and industrial applications to gain better understanding of thefundamental processes and to optimize fuel cell designs before building a prototype forengineering application. In this study, we used a single-phase, fully three dimensionalsimulation model for PEMFC that can deal with both anode and cathode flow field forexamining the micro flow channel with electrochemical reaction. The results show thathydrogen and oxygen were solely supplied to the membrane by diffusion mechanism ratherthan convection transport, and the higher pressure drop at cathode side is thought to becaused by higher flow rate of oxygen at cathode. And it is found that the amount of water incathode channel was determined by water formation due to electrochemical reaction pluselectro-osmotic mass flux directing toward the cathode side. And it is very important tomodel the back diffusion and electro-osmotic mass flux accurately since the two flux wasclosely correlated each other and greatly influenced for determination of ionic conductivityof the membrane which directly affects the performance of fuel cell.

  12. A Comparison of the Plastic-Flow Response of a Powder-Metallurgy Nickel-Base Superalloy Under Nominally-Isothermal and Transient-Heating Hot-Working Conditions

    Science.gov (United States)

    Semiatin, S. L.; Mahaffey, D. W.; Tung, D. J.; Zhang, W.; Senkov, O. N.

    2017-04-01

    The flow-stress behavior at hot-working temperatures and strain rates of the powder-metallurgy superalloy LSHR was determined under nominally-isothermal and transient-heating conditions. Two conventional methods, compression of right-circular cylinders and torsion of thin-walled tubes, were used for isothermal tests. A direct-resistance-heating technique utilizing torsion of round-bar specimens in a Gleeble® machine was applied for both isothermal and transient-heating conditions. When expressed in terms of effective stress and strain, baseline data determined by the two conventional methods showed good agreement. With the aid of a flow-localization analysis to assess the confounding influence of axial (and radial) temperature gradients on deformation uniformity, the flow stresses determined from nominally-isothermal Gleeble® torsion tests were shown to be broadly similar to those from the conventional tests. With regard to transient phenomena, Gleeble® tests were also useful in quantifying the effect of rapid heating and short soak time on the observed higher flow stress associated with a metastable microstructure. The present work also introduces two new test techniques using direct-resistance-heated torsion specimens. One involves continuous heating under constant-torque conditions, and the other comprises testing an individual specimen at a series of temperatures and strain rates. Using a single specimen, the former method enabled the determination of the apparent activation energy for plastic flow, which was similar to that determined from the series of isothermal tests; the latter provided a low-cost, high-throughput approach to quantify the flow behavior.

  13. Transient magnetoviscosity of dilute ferrofluids

    International Nuclear Information System (INIS)

    Soto-Aquino, Denisse; Rinaldi, Carlos

    2011-01-01

    The magnetic field induced change in the viscosity of a ferrofluid, commonly known as the magnetoviscous effect and parameterized through the magnetoviscosity, is one of the most interesting and practically relevant aspects of ferrofluid phenomena. Although the steady state behavior of ferrofluids under conditions of applied constant magnetic fields has received considerable attention, comparatively little attention has been given to the transient response of the magnetoviscosity to changes in the applied magnetic field or rate of shear deformation. Such transient response can provide further insight into the dynamics of ferrofluids and find practical application in the design of devices that take advantage of the magnetoviscous effect and inevitably must deal with changes in the applied magnetic field and deformation. In this contribution Brownian dynamics simulations and a simple model based on the ferrohydrodynamics equations are applied to explore the dependence of the transient magnetoviscosity for two cases: (I) a ferrofluid in a constant shear flow wherein the magnetic field is suddenly turned on, and (II) a ferrofluid in a constant magnetic field wherein the shear flow is suddenly started. Both simulations and analysis show that the transient approach to a steady state magnetoviscosity can be either monotonic or oscillatory depending on the relative magnitudes of the applied magnetic field and shear rate. - Research Highlights: →Rotational Brownian dynamics simulations were used to study the transient behavior of the magnetoviscosity of ferrofluids. →Damped and oscillatory approach to steady state magnetoviscosity was observed for step changes in shear rate and magnetic field. →A model based on the ferrohydrodynamics equations qualitatively captured the damped and oscillatory features of the transient response →The transient behavior is due to the interplay of hydrodynamic, magnetic, and Brownian torques on the suspended particles.

  14. Flow

    DEFF Research Database (Denmark)

    Knoop, Hans Henrik

    2006-01-01

    FLOW. Orden i hovedet på den fede måde Oplevelsesmæssigt er flow-tilstanden kendetegnet ved at man er fuldstændig involveret, fokuseret og koncentreret; at man oplever stor indre klarhed ved at vide hvad der skal gøres, og i hvilket omfang det lykkes; at man ved at det er muligt at løse opgaven...

  15. A three-field model of transient 3D multiphase, three-component flow for the computer code IV A3. Pt. 2

    International Nuclear Information System (INIS)

    Kolev, N.I.

    1991-12-01

    The second part of the IVA3 code description contains the constitutive models used for the interfacial transport phenomena and the code validation results. First 20 flow patterns are defined and the transition criteria are discussed. The dynamic fragmentation and coalescence models used in IVA3 are documented. After the description of the models for predicting the flow patterns and flow structure sizes the models for the interfacial mechanical interaction are described. Finally the models for interfacial heat and mass transfer are given with emphasis on the time averaging of the heat and mass source terms. The code validation passes several stages from simple tests on well known benchmarks trough simulation of one-, two-, and three-phase flows in simple and complicated geometries. The gradually increase of the complexity and the successful comparison of the predictions with experimental data is the main characteristic of the verification procedure. It is demonstrated by several examples that IVA3 is a powerful tool for three-fluid modelling of complicated three-phase flows in complex geometry with strong thermal and mechanical interaction between the velocity fields. (orig.) [de

  16. Current interruption transients calculation

    CERN Document Server

    Peelo, David F

    2014-01-01

    Provides an original, detailed and practical description of current interruption transients, origins, and the circuits involved, and how they can be calculated Current Interruption Transients Calculationis a comprehensive resource for the understanding, calculation and analysis of the transient recovery voltages (TRVs) and related re-ignition or re-striking transients associated with fault current interruption and the switching of inductive and capacitive load currents in circuits. This book provides an original, detailed and practical description of current interruption transients, origins,

  17. Transient myocardial ischemia during nifedipine therapy in stable angina pectoris, and its relation to coronary collateral flow and comparison with metoprolol

    DEFF Research Database (Denmark)

    Egstrup, K; Andersen, P E

    1993-01-01

    There are conflicting results concerning the anti-ischemic effect of nifedipine in patients with chronic stable angina. Therefore, the purpose of this study was to assess whether the anti-ischemic effect of nifedipine may be related to coronary collateral circulation. Forty-one patients with stable...... of collateral circulation. In 17 patients, angiographically poor or no collateral flow was observed (group 1), and 24 had good collateral flow (group 2). Nifedipine was administered to 20 patients (8 in group 1, and 12 in group 2). In group 1, nifedipine reduced the frequency of total and asymptomatic ischemic...

  18. Three dimensional calculations of the primary coolant flow in a 900 MW PWR vessel. Steady state and transients computations; Calculs tridimensionnels d`un ecoulement dans une cuve d`un reacteur a eau pressurisee 900 MWe

    Energy Technology Data Exchange (ETDEWEB)

    Martin, A.; Alvarez, D.; Cases, F.

    1996-03-01

    The paper explains the chronological account and the first results obtained in the R and D program on the mixing in the 900 MW PWR vessels. After the presentation of the plant type simulated, we define the numerical tool, the (Finite Element Modelling) FEM N3S code. Two results are presented with a comparison with the experiment results issued of the BORA BORA mock up. The first case is dealing with the isothermal steady state mixing in the vessel with the three loops mass flow rate balanced. This case identified as a validation of our numerical tool shows a good agreement. The second case is dealing with the transient mixing of a clear plug in the vessel when one primary pump starts-up. We compare the numerical and experiment results giving the mean boron concentration at the core inlet for several clear water plugs. The results show again a good agreement. (authors). 12 refs., 10 figs., 1 tab.

  19. Oral Levosimendan Increases Cerebral Blood Flow Velocities in Patients with a History of Stroke or Transient Ischemic Attack: A Pilot Safety Study

    Directory of Open Access Journals (Sweden)

    Matti Kivikko, MD, PhD

    2015-12-01

    Conclusions: Oral levosimendan increases cerebral blood flow velocities and diminishes NT-pro-BNP levels in patients with earlier ischemic cerebrovascular event. Daily doses up to 1.0 mg were well tolerated, whereas the 2.0 mg dose level induced an increase in ventricular extrasystoles. ClinicalTrials.gov identifier: NCT00698763.

  20. RELAP/SCDAPSIM/MOD4.0 modification for transient accident scenario of Test Blanket Modules in ITER involving helium flows into heavy liquid metal

    Energy Technology Data Exchange (ETDEWEB)

    Freixa, J.; Pérez, M.; Mas de les Valls, E.; Batet, L.; Sandeep, T.; Chaudhari, V.; Reventós, F.

    2015-07-01

    The Institute for Plasma Research (IPR), India, is currently involved in the design and development of its Test Blanket Module (TBM) for testing in ITER (International Thermo nuclear Experimental Reactor). The Indian TBM concept is a Lead-Lithium cooled Ceramic Breeder (LLCB), which utilizes lead-lithium eutectic alloy (LLE) as tritium breeder, neutron multiplier and coolant. The first wall facing the plasma is cooled by helium gas. In preparation of the regulatory safety files of ITER-TBM, a number of off-normal event sequences have been postulated. Thermal hydraulic safety analyses of the TBM system will be carried out with the system code RELAP/SCDAPSIM/MOD4.0 which was initially designed to predict the behavior of light water reactor systems during normal and accidental conditions. In order to analyze some of the postulated off-normal events, there is the need to simulate the mixing of Helium and Lead-Lithium fluids. The Technical University of Catalonia is cooperating with IPR to implement the necessary changes in the code to allow for the mixing of helium and liquid metal. In the present study, the RELAP/SCDAPSIM/MOD4 two-phase flow 6-equations structure has been modified to allow for the mixture of LLE in the liquid phase with dry Helium in the gas phase. Practically obtaining a two-fluid 6-equation model where each fluid is simulated with a set of energy, mass and momentum balance equations. A preliminary flow regime map for LLE and helium flow has been developed on the basis of numerical simulations with the OpenFOAM CFD toolkit. The new code modifications have been verified for vertical and horizontal configurations. (Author)

  1. Pure axial flow of viscoelastic fluids in rectangular microchannels under combined effects of electro-osmosis and hydrodynamics

    Science.gov (United States)

    Reshadi, Milad; Saidi, Mohammad Hassan; Ebrahimi, Abbas

    2017-04-01

    This paper presents an analysis of the combined electro-osmotic and pressure-driven axial flows of viscoelastic fluids in a rectangular microchannel with arbitrary aspect ratios. The rheological behavior of the fluid is described by the complete form of Phan-Thien-Tanner (PTT) model with the Gordon-Schowalter convected derivative which covers the upper convected Maxwell, Johnson-Segalman and FENE-P models. Our numerical simulation is based on the computation of 2D Poisson-Boltzmann, Cauchy momentum and PTT constitutive equations. The solution of these governing nonlinear coupled set of equations is obtained by using the second-order central finite difference method in a non-uniform grid system and is verified against 1D analytical solution of the velocity profile with less than 0.06% relative error. Also, a parametric study is carried out to investigate the effect of channel aspect ratio (width to height), wall zeta potential and the Debye-Hückel parameter on 2D velocity profile, volumetric flow rate and the Poiseuille number in the mixed EO/PD flows of viscoelastic fluids with different Weissenberg numbers. Our results show that, for low channel aspect ratios, the previous 1D analytical models underestimate the velocity profile at the channel half-width centerline in the case of favorable pressure gradients and overestimate it in the case of adverse pressure gradients. The results reveal that the inapplicability of the Debye-Hückel approximation at high zeta potentials is more significant for higher Weissenberg number fluids. Also, it is found that, under the specified values of electrokinetic parameters, there is a threshold for velocity scale ratio in which the Poiseuille number is approximately independent of channel aspect ratio.

  2. Pure axial flow of viscoelastic fluids in rectangular microchannels under combined effects of electro-osmosis and hydrodynamics

    Science.gov (United States)

    Reshadi, Milad; Saidi, Mohammad Hassan; Ebrahimi, Abbas

    2018-02-01

    This paper presents an analysis of the combined electro-osmotic and pressure-driven axial flows of viscoelastic fluids in a rectangular microchannel with arbitrary aspect ratios. The rheological behavior of the fluid is described by the complete form of Phan-Thien-Tanner (PTT) model with the Gordon-Schowalter convected derivative which covers the upper convected Maxwell, Johnson-Segalman and FENE-P models. Our numerical simulation is based on the computation of 2D Poisson-Boltzmann, Cauchy momentum and PTT constitutive equations. The solution of these governing nonlinear coupled set of equations is obtained by using the second-order central finite difference method in a non-uniform grid system and is verified against 1D analytical solution of the velocity profile with less than 0.06% relative error. Also, a parametric study is carried out to investigate the effect of channel aspect ratio (width to height), wall zeta potential and the Debye-Hückel parameter on 2D velocity profile, volumetric flow rate and the Poiseuille number in the mixed EO/PD flows of viscoelastic fluids with different Weissenberg numbers. Our results show that, for low channel aspect ratios, the previous 1D analytical models underestimate the velocity profile at the channel half-width centerline in the case of favorable pressure gradients and overestimate it in the case of adverse pressure gradients. The results reveal that the inapplicability of the Debye-Hückel approximation at high zeta potentials is more significant for higher Weissenberg number fluids. Also, it is found that, under the specified values of electrokinetic parameters, there is a threshold for velocity scale ratio in which the Poiseuille number is approximately independent of channel aspect ratio.

  3. Demonstration of Electro-Osmotic Pulse Technology in Earth-Covered Magazines at Fort A.P. Hill, VA

    Science.gov (United States)

    2009-08-01

    damage, and growth of pathogens such as mold and microorganisms. At Fort A.P. Hill, VA, large amounts of water seep through the concrete walls...to the walls using galvanized steel angles. The an- gles were held in place using screws going through the wall and base with nuts to keep them...between them at the apex of the arch and held in place using nuts . Figure C-10 shows the completed model under testing. Prior to assembling the

  4. PSH Transient Simulation Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-12-21

    PSH Transient Simulation Modeling presentation from the WPTO FY14 - FY16 Peer Review. Transient effects are an important consideration when designing a PSH system, yet numerical techniques for hydraulic transient analysis still need improvements for adjustable-speed (AS) reversible pump-turbine applications.

  5. Full-Volume, Three-Dimensional, Transient Measurements of Bubbly Flows Using Particle Tracking Velocimetry and Shadow Image Velocimetry Coupled with Pattern Recognition Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Yassin Hassan

    2001-11-30

    Develop a state-of-the-art non-intrusive diagnostic tool to perform simultaneous measurements of both the temporal and three-dimensional spatial velocity of the two phases of a bubbly flow. These measurements are required to provide a foundation for studying the constitutive closure relations needed in computational fluid dynamics and best-estimate thermal hydraulic codes employed in nuclear reactor safety analysis and severe accident simulation. Such kinds of full-field measurements are not achievable through the commonly used point-measurement techniques, such as hot wire, conductance probe, laser Doppler anemometry, etc. The results can also be used in several other applications, such as the dynamic transport of pollutants in water or studies of the dispersion of hazardous waste.

  6. Full-Volume, Three-Dimensional, Transient Measurements of Bubbly Flows Using Particle Tracking Velocimetry and Shadow Image Velocimetry Coupled with Pattern Recognition Techniques

    International Nuclear Information System (INIS)

    Yassin Hassan

    2001-01-01

    Develop a state-of-the-art non-intrusive diagnostic tool to perform simultaneous measurements of both the temporal and three-dimensional spatial velocity of the two phases of a bubbly flow. These measurements are required to provide a foundation for studying the constitutive closure relations needed in computational fluid dynamics and best-estimate thermal hydraulic codes employed in nuclear reactor safety analysis and severe accident simulation. Such kinds of full-field measurements are not achievable through the commonly used point-measurement techniques, such as hot wire, conductance probe, laser Doppler anemometry, etc. The results can also be used in several other applications, such as the dynamic transport of pollutants in water or studies of the dispersion of hazardous waste

  7. Theory and verification for the GRASP II code for adjoint-sensitivity analysis of steady-state and transient ground-water flow

    Energy Technology Data Exchange (ETDEWEB)

    RamaRao, B.S.; Reeves, M. (INTERA, Inc., Austin, TX (USA))

    1990-10-01

    Calibration of a numerical model of the regional ground-water flow in the Culebra dolomite at the Waste Isolation Pilot Plant in southeastern New Mexico, has been performed by an interative parameter-fitting procedure. Parameterization has been secured by choosing to assign the transmissivity values at a limited number of selected locations, designated as pilot points. The transmissivity distribution in the model is derived by kriging the combined pool of measured and pilot-plant transmissivities. Iterating on the twin steps of sequentially adding additional pilot point(s) and kriging leads to the model of required accuracy, as judged by a weighted least-square-error objective function. At the end of calibration, it must be ensured that the correlation structure of the measured transmissivities is broadly preserved by the pilot-plant transmissivities. Adjoint-sensitivity analysis of the model has been coupled with kriging to provide objectively the optimal location of the pilot points during an iteration. The pilot-point transmissivities have been adjusted by modeler's judgement incorporating information, where available, on local geologic conditions and large-scale hydraulic interference tests, in order to minimize the objective function. 43 refs., 5 figs., 5 tabs.

  8. Nonlinear Diffusion and Transient Osmosis

    International Nuclear Information System (INIS)

    Igarashi, Akira; Rondoni, Lamberto; Botrugno, Antonio; Pizzi, Marco

    2011-01-01

    We investigate both analytically and numerically the concentration dynamics of a solution in two containers connected by a narrow and short channel, in which diffusion obeys a porous medium equation. We also consider the variation of the pressure in the containers due to the flow of matter in the channel. In particular, we identify a phenomenon, which depends on the transport of matter across nano-porous membranes, which we call ''transient osmosis . We find that nonlinear diffusion of the porous medium equation type allows numerous different osmotic-like phenomena, which are not present in the case of ordinary Fickian diffusion. Experimental results suggest one possible candidate for transiently osmotic processes. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  9. Spectroscopic classification of transients

    DEFF Research Database (Denmark)

    Stritzinger, M. D.; Fraser, M.; Hummelmose, N. N.

    2017-01-01

    We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017.......We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017....

  10. Fluid dynamic transient analysis

    International Nuclear Information System (INIS)

    Vilhena Reigosa, R. de

    1992-01-01

    This paper describes the methodology adopted at NUCLEN for the fluid dynamic analyses for ANGRA 2. The fluid dynamic analysis allows, through computer codes to simulate and quantify the loads resulting from fluid dynamic transients caused by postulated ruptures or operational transients, in the piping of the safety systems and of the important operational systems. (author)

  11. Transient Seepage for Levee Engineering Analyses

    Science.gov (United States)

    Tracy, F. T.

    2017-12-01

    Historically, steady-state seepage analyses have been a key tool for designing levees by practicing engineers. However, with the advances in computer modeling, transient seepage analysis has become a potentially viable tool. A complication is that the levees usually have partially saturated flow, and this is significantly more complicated in transient flow. This poster illustrates four elements of our research in partially saturated flow relating to the use of transient seepage for levee design: (1) a comparison of results from SEEP2D, SEEP/W, and SLIDE for a generic levee cross section common to the southeastern United States; (2) the results of a sensitivity study of varying saturated hydraulic conductivity, the volumetric water content function (as represented by van Genuchten), and volumetric compressibility; (3) a comparison of when soils do and do not exhibit hysteresis, and (4) a description of proper and improper use of transient seepage in levee design. The variables considered for the sensitivity and hysteresis studies are pore pressure beneath the confining layer at the toe, the flow rate through the levee system, and a levee saturation coefficient varying between 0 and 1. Getting results for SEEP2D, SEEP/W, and SLIDE to match proved more difficult than expected. After some effort, the results matched reasonably well. Differences in results were caused by various factors, including bugs, different finite element meshes, different numerical formulations of the system of nonlinear equations to be solved, and differences in convergence criteria. Varying volumetric compressibility affected the above test variables the most. The levee saturation coefficient was most affected by the use of hysteresis. The improper use of pore pressures from a transient finite element seepage solution imported into a slope stability computation was found to be the most grievous mistake in using transient seepage in the design of levees.

  12. Transient flows in active porous media

    DEFF Research Database (Denmark)

    Kosmidis, Lefteris I.; Jensen, Kaare Hartvig

    2017-01-01

    . The physiochemical mechanisms that induce internal volume modifications have been widely studied. The coupling between induced volume changes and solute transport through porous materials, however, is not well understood. Here, we consider advective and diffusive transport through a small channel linking two large...

  13. Transient Ischemic Attack

    Medline Plus

    Full Text Available ... Ischemic Attack TIA , or transient ischemic attack, is a "mini stroke" that occurs when a blood clot blocks an artery for a short time. The only difference between a stroke ...

  14. Transient Ischemic Attack

    Medline Plus

    Full Text Available ... TIA , or transient ischemic attack, is a "mini stroke" that occurs when a blood clot blocks an ... a short time. The only difference between a stroke and TIA is that with TIA the blockage ...

  15. Pressure Transient Analysis of Dual Fractal Reservoir

    Directory of Open Access Journals (Sweden)

    Xiao-Hua Tan

    2013-01-01

    Full Text Available A dual fractal reservoir transient flow model was created by embedding a fracture system simulated by a tree-shaped fractal network into a matrix system simulated by fractal porous media. The dimensionless bottom hole pressure model was created using the Laplace transform and Stehfest numerical inversion methods. According to the model's solution, the bilogarithmic type curves of the dual fractal reservoirs are illustrated, and the influence of different fractal factors on pressure transient responses is discussed. This semianalytical model provides a practical and reliable method for empirical applications.

  16. Transient coupled calculations of the Molten Salt Fast Reactor using the Transient Fission Matrix approach

    Energy Technology Data Exchange (ETDEWEB)

    Laureau, A., E-mail: laureau.axel@gmail.com; Heuer, D.; Merle-Lucotte, E.; Rubiolo, P.R.; Allibert, M.; Aufiero, M.

    2017-05-15

    Highlights: • Neutronic ‘Transient Fission Matrix’ approach coupled to the CFD OpenFOAM code. • Fission Matrix interpolation model for fast spectrum homogeneous reactors. • Application for coupled calculations of the Molten Salt Fast Reactor. • Load following, over-cooling and reactivity insertion transient studies. • Validation of the reactor intrinsic stability for normal and accidental transients. - Abstract: In this paper we present transient studies of the Molten Salt Fast Reactor (MSFR). This generation IV reactor is characterized by a liquid fuel circulating in the core cavity, requiring specific simulation tools. An innovative neutronic approach called “Transient Fission Matrix” is used to perform spatial kinetic calculations with a reduced computational cost through a pre-calculation of the Monte Carlo spatial and temporal response of the system. Coupled to this neutronic approach, the Computational Fluid Dynamics code OpenFOAM is used to model the complex flow pattern in the core. An accurate interpolation model developed to take into account the thermal hydraulics feedback on the neutronics including reactivity and neutron flux variation is presented. Finally different transient studies of the reactor in normal and accidental operating conditions are detailed such as reactivity insertion and load following capacities. The results of these studies illustrate the excellent behavior of the MSFR during such transients.

  17. Mitigation of thermal transients by tube bundle inlet plenum design

    International Nuclear Information System (INIS)

    Oras, J.J.; Kasza, K.E.

    1984-06-01

    A multiphase program aimed at investigating the importance of thermal buoyancy to LMFBR steam-generator and heat-exchanger thermal hydraulics under low-flow transient conditions is being conducted in the Argonne Mixing Components Test Facility (MCTF) on a 60 0 sector shell-side flow model of the Westinghouse straight-tube steam generator being developed under the US/DOE large-component development program. A series of shell-side constant-flow thermal-downramp transient tests have been conducted focusing on the phenomenon of thermal-buoyancy-induced-flow channeling. In addition, it was discovered that a shell-inlet flow-distribution plenum can play a significant role in mitigating the severity of a thermal transient entering a steam generator or heat exchanger

  18. Transient global amnesia: current perspectives

    Directory of Open Access Journals (Sweden)

    Spiegel DR

    2017-10-01

    Full Text Available David R Spiegel, Justin Smith, Ryan R Wade, Nithya Cherukuru, Aneel Ursani, Yuliya Dobruskina, Taylor Crist, Robert F Busch, Rahim M Dhanani, Nicholas Dreyer Department of Psychiatry and Behavioral Sciences, Eastern Virginia Medical School, Norfolk, VA, USA Abstract: Transient global amnesia (TGA is a clinical syndrome characterized by the sudden onset of an extraordinarily large reduction of anterograde and a somewhat milder reduction of retrograde episodic long-term memory. Additionally, executive functions are described as diminished. Although it is suggested that various factors, such as migraine, focal ischemia, venous flow abnormalities, and epileptic phenomena, are involved in the pathophysiology and differential diagnosis of TGA, the factors triggering the emergence of these lesions are still elusive. Recent data suggest that the vulnerability of CA1 neurons to metabolic stress plays a pivotal part in the pathophysiological cascade, leading to an impairment of hippocampal function during TGA. In this review, we discuss clinical aspects, new imaging findings, and recent clinical–epidemiological data with regard to the phenotype, functional anatomy, and putative cellular mechanisms of TGA. Keywords: transient global amnesia, vascular, migraines, psychiatric

  19. Boiling and burnout phenomena under transient heat input, 1

    International Nuclear Information System (INIS)

    Aoki, Shigebumi; Kozawa, Yoshiyuki; Iwasaki, Hideaki.

    1976-01-01

    In order to simulate the thermo-hydrodynamic conditions at reactor power excursions, a test piece was placed in a forced convective channel and heated with exponential power inputs. The boiling heat transfer and the burnout heat flux under the transient heat input were measured, and pressure and water temperature changes in the test section were recorded at the same time. Following experimental results were obtained; (1) Transient boiling heat transfer characteristics at high heat flux stayed on the stationary nucleate boiling curve of each flow condition, or extrapolated line of the curves. (2) Transient burnout heat flux increased remarkably with decreasing heating-time-constant, when the flow rate was lower and the subcooling was higher. (3) Transient burnout phenomena were expressed with the relation of (q sub(max) - q sub(sBO)) tau = constant at several flow conditions. This relation was derived from the stationary burnout mechanism of pool boiling. (auth.)

  20. Analysis of transient flows in gasoline direct injection systems: effects on unsteady air entrainment by the spray; Analyse des ecoulements transitoires dans les systemes d'injection directe essence: effets sur l'entrainement d'air instationnaire du spray

    Energy Technology Data Exchange (ETDEWEB)

    Delay, G.

    2005-03-15

    The aim of this study is to determine instantaneous liquid flow rate oscillations effect on non stationary air entrainment of an injector conical spray (Gasoline Direct Injection). The tools we use are either experimental or numerical ones. An instantaneous flow rate determination method is used. It is based on pulsated flows physics and only requires the velocity at the centerline of a pipe mounted just before the injector. So, it is possible to 'rebuild' the instantaneous velocity distributions and then to get the instantaneous liquid flow rate (Laser Doppler Anemometry measurements). A mechanical and hydraulics modeling software (AMESim) is necessary to get injector outlet flow rate. Simulations are validated by both 'rebuilding' method results and common rail pressure measurements. Fluorescent Particle Image Velocimetry (FPIV), suited to dense two -phase flows, is used to measure air flow around and inside the conical spray. Velocity measurements close to the spray frontier are used to compute instantaneous air entrainment. Considering droplets momentum exchange with air and thanks to droplets diameters and liquid velocities measurements at the nozzle exit, a transient air entrainment model is proposed according to FPIV measurements. (author)

  1. Coupled equations for transient water flow, heat flow, and ...

    Indian Academy of Sciences (India)

    and deformation,each of which is represented by a diffusion-type of partial differential ... Department of Materials Science and Engineering, Department of Environmental Science, Policy and Management, 210 Hearst Memorial Mining Building, ...

  2. Transient Heat Conduction

    DEFF Research Database (Denmark)

    Rode, Carsten

    1998-01-01

    Analytical theory of transient heat conduction.Fourier's law. General heat conducation equation. Thermal diffusivity. Biot and Fourier numbers. Lumped analysis and time constant. Semi-infinite body: fixed surface temperature, convective heat transfer at the surface, or constant surface heat flux...

  3. Compressive Transient Imaging

    KAUST Repository

    Sun, Qilin

    2017-04-01

    High resolution transient/3D imaging technology is of high interest in both scientific research and commercial application. Nowadays, all of the transient imaging methods suffer from low resolution or time consuming mechanical scanning. We proposed a new method based on TCSPC and Compressive Sensing to achieve a high resolution transient imaging with a several seconds capturing process. Picosecond laser sends a serious of equal interval pulse while synchronized SPAD camera\\'s detecting gate window has a precise phase delay at each cycle. After capturing enough points, we are able to make up a whole signal. By inserting a DMD device into the system, we are able to modulate all the frames of data using binary random patterns to reconstruct a super resolution transient/3D image later. Because the low fill factor of SPAD sensor will make a compressive sensing scenario ill-conditioned, We designed and fabricated a diffractive microlens array. We proposed a new CS reconstruction algorithm which is able to denoise at the same time for the measurements suffering from Poisson noise. Instead of a single SPAD senor, we chose a SPAD array because it can drastically reduce the requirement for the number of measurements and its reconstruction time. Further more, it not easy to reconstruct a high resolution image with only one single sensor while for an array, it just needs to reconstruct small patches and a few measurements. In this thesis, we evaluated the reconstruction methods using both clean measurements and the version corrupted by Poisson noise. The results show how the integration over the layers influence the image quality and our algorithm works well while the measurements suffer from non-trival Poisson noise. It\\'s a breakthrough in the areas of both transient imaging and compressive sensing.

  4. Simultaneous transport of water and solutes under transient ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Earth System Science; Volume 117; Issue 4. Simultaneous transport of water and solutes under transient unsaturated flow conditions – A case study ... Keywords. Hydraulic conductivity; infiltration; leaching; Malaprabha; modeling; permeability; salinity; solute transport; SWIM model; water flow.

  5. Explosive and radio-selected Transients: Transient Astronomy with ...

    Indian Academy of Sciences (India)

    40

    SKA), large samples of explosive transients are expected to be discovered. Radio wavelengths, especially in commensal survey mode, are particularly well suited for uncovering the complex transient phenomena. This is because ob- servations ...

  6. Failure-mode transition in transient polymer networks with particle-based simulations

    NARCIS (Netherlands)

    Sprakel, J.H.B.; Spruijt, E.; Padding, J.T.; Briels, W.J.

    2009-01-01

    Transient polymer networks are known to undergo a wide variety of viscoelastic flow instabilities. In this paper we investigate two of these flow failure modes: shear banding and melt fracture. Using particle-based simulations we reveal a transition from gradient banding to fracture in transient

  7. Studies on an Electromagnetic Transient Model of Offshore Wind Turbines and Lightning Transient Overvoltage Considering Lightning Channel Wave Impedance

    Directory of Open Access Journals (Sweden)

    Li Zhang

    2017-12-01

    Full Text Available In recent years, with the rapid development of offshore wind turbines (WTs, the problem of lightning strikes has become more and more prominent. In order to reduce the failure rate caused by the transient overvoltage of lightning struck offshore WTs, the influencing factors and the response rules of transient overvoltage are analyzed. In this paper, a new integrated electromagnetic transient model of offshore WTs is established by using the numerical calculation method of the electromagnetic field first. Then, based on the lightning model and considering the impedance of the lightning channel, the transient overvoltage of lightning is analyzed. Last, the electromagnetic transient model of offshore WTs is simulated and analyzed by using the alternative transients program electro-magnetic transient program (ATP-EMTP software. The influence factors of lightning transient overvoltage are studied. The main influencing factors include the sea depth, the blade length, the tower height, the lightning flow parameters, the lightning strike point, and the blade rotation position. The simulation results show that the influencing factors mentioned above have different effects on the lightning transient overvoltage. The results of the study have some guiding significance for the design of the lightning protection of the engine room.

  8. Transient behaviour of small HTR for cogeneration

    International Nuclear Information System (INIS)

    Verkerk, E.C.; Van Heek, A.I.

    2000-01-01

    The Dutch market for combined generation of heat and power identifies a unit size of 40 MW thermal for the conceptual design of a nuclear cogeneration plant. The ACACIA system provides 14 MWe electricity combined with 17 t/h of high temperature steam (220 deg C, 10 bar) with a pebble-bed high temperature reactor directly coupled with a helium compressor and a helium turbine. The design of this small CHP unit that is used for industrial applications is mainly based on a pre-feasibility study in 1996, performed by a joint working group of five Dutch organisations, in which technical feasibility was shown. Thermal hydraulic and reactor physics analyses show favourable control characteristics during normal operation and a benign response to loss of helium coolant and loss of flow conditions. Throughout the response on these highly infrequent conditions, ample margin exists between the highest fuel temperatures and the temperature above which fuel degradation will occur. To come to quantitative statements about the ACACIA transient behaviour, a calculational coupling between the high temperature reactor core analysis code package PANTHER/DIREKT and the thermal hydraulic code RELAP5 for the energy conversion system has been made. This coupling offers a more realistic simulation of the entire system, since it removes the necessity of forcing boundary conditions on the simulation models at the data transfer points. In this paper, the models used for the dynamic components of the energy conversion system are described, and the results of the calculation for two operational transients in order to demonstrate the effects of the interaction between reactor core and its energy conversion system are shown. Several transient cases that are representative as operational transients for an HTR will be discussed, including one representing a load rejection case that shows the functioning of the control system, in particular the bypass valve. Another transient is a load following

  9. Transient Astrophysics Probe

    Science.gov (United States)

    Camp, Jordan; Transient Astrophysics Probe Team

    2018-01-01

    The Transient Astrophysics Probe (TAP) is a wide-field multi-wavelength transient mission proposed for flight starting in the late 2020s. The mission instruments include unique “Lobster-eye” imaging soft X-ray optics that allow a ~1600 deg2 FoV; a high sensitivity, 1 deg2 FoV soft X-ray telescope; a 1 deg2 FoV Infrared telescope with bandpass 0.6-3 micron; and a set of 8 NaI gamma-ray detectors. TAP’s most exciting capability will be the observation of tens per year of X-ray and IR counterparts of GWs involving stellar mass black holes and neutron stars detected by LIGO/Virgo/KAGRA/LIGO-India, and possibly several per year X-ray counterparts of GWs from supermassive black holes, detected by LISA and Pulsar Timing Arrays. TAP will also discover hundreds of X-ray transients related to compact objects, including tidal disruption events, supernova shock breakouts, and Gamma-Ray Bursts from the epoch of reionization.

  10. Metastability of transient states

    Science.gov (United States)

    Rafailov, Michael K.

    2017-05-01

    High intensity ultrashort pulse causes dramatic perturbations in electronic structure of condensed matter. In the same time energy in high intensity single pulse may not be sufficient to disrupt sample thermal equilibrium. Interesting experimental results in ultrashort pulse photo-excited solids have been reported recently on transient athermal phenomena induced by ultrashort high intensity low energy pulse - phenomena related to both athermal phase transitions and athermal state changes. Athermal non-equilibrium of electronic system - and induced changes in magnetic and optical states, may exist only for a period of time comparable to excited carriers' relaxation time. That time is not sufficient for emerging application ranging from light induced superconductivity to infrared countermeasures. While single pulse interaction with condensed matter leading to transit state appearance is well observed, documented, and, to some extends, explained, one of the major problem is to maintain meta-stability of such transient states. Metastability of athermal non-equilibrium that could last well beyond electronic system relaxation time. The objective of this paper is to discuss some issues and approaches to meta-stability of transient states induced by ultrashort pulses in condensed matter.

  11. Transient or permanent fisheye views

    DEFF Research Database (Denmark)

    Jakobsen, Mikkel Rønne; Hornbæk, Kasper

    2012-01-01

    Transient use of information visualization may support specific tasks without permanently changing the user interface. Transient visualizations provide immediate and transient use of information visualization close to and in the context of the user’s focus of attention. Little is known, however, ...

  12. [Chronic subdural hematoma and transient neurologic deficits].

    Science.gov (United States)

    Nicoli, F; Milandre, L; Lemarquis, P; Bazan, M; Jau, P

    1990-01-01

    Three cases of chronic subdural hematoma (CSDH) revealed by transient neurological accidents are reported. Although well-known this condition is rare: 1 to 9 p. 100 of CSDHs. Questioning may bring out a history of cranial injury and headache, even minor ones, which are unusual in transient ischemic accidents (TIA). Transient phenomena, such as motor aphasia or speech interruption, point to the diagnosis, especially in male patients over 60 years of age. The finding at electroencephalography of a delta activity more than 48 hours after a TND should exclude the diagnosis of TIA until a CT scan is performed. Since the causes of neurological deficits regressing within less than 24 hours may be ischemia as well a hemorrhage or tumour, the term of transient neurological accident (TNA) should preferably be used, and an emergency CT scan should be performed for diagnostic and therapeutic purposes. Owing to the possibility of another concomitant cause of TNA, the finding of a subdural haematoma should not deter from pursuing cardiovascular examinations. The mechanism of TNA probably involves a vascular factor, as suggested by I-123 IMP cerebral SPECT which shows an intercritical decrease in cerebral blood flow and/or an epileptic factor.

  13. Respiratory effects of transient axial acceleration.

    Science.gov (United States)

    Loring, S H; Lee, H T; Butler, J P

    2001-06-01

    Whereas gravity has an inspiratory effect in upright subjects, transient upward acceleration is reported to have an expiratory effect. To explore the respiratory effects of transient axial accelerations, we measured axial acceleration at the head and transrespiratory pressure or airflow in five subjects as they were dropped or lifted on a platform. For the first 100 ms, upward acceleration caused a decrease in mouth pressure and inspiratory flow, and downward acceleration caused the opposite. We also simulated these experimental observations by using a computational model of a passive respiratory system based on anatomical data and normal respiratory characteristics. After 100 ms, respiratory airflow in our subjects became highly variable, no longer varying with acceleration. Electromyograms of thoracic and abdominal respiratory muscles showed bursts of activity beginning 40-125 ms after acceleration, suggesting reflex responses responsible for subsequent flow variability. We conclude that, in relaxed subjects, transient upward axial acceleration causes inspiratory airflow and downward acceleration causes expiratory airflow, but that after ~100 ms, reflex activation of respiratory musculature largely determines airflow.

  14. Familial Transient Global Amnesia

    Directory of Open Access Journals (Sweden)

    R.Rhys Davies

    2012-12-01

    Full Text Available Following an episode of typical transient global amnesia (TGA, a female patient reported similar clinical attacks in 2 maternal aunts. Prior reports of familial TGA are few, and no previous account of affected relatives more distant than siblings or parents was discovered in a literature survey. The aetiology of familial TGA is unknown. A pathophysiological mechanism akin to that in migraine attacks, comorbidity reported in a number of the examples of familial TGA, is one possibility. The study of familial TGA cases might facilitate the understanding of TGA aetiology.

  15. Transient Storage in Zero-Order Channels Draining Arctic Hillslopes

    Science.gov (United States)

    Cook, C. L.; Harms, T.; Wlostowski, A. N.; Gooseff, M. N.

    2015-12-01

    Water tracks are linear regions of preferential hydrologic flow on arctic hillslopes that discharge to lakes and higher-order streams. In comparison to headwater streams, which encompass flow velocities of 0.1 - 1.0 + m/s, water velocity in water tracks ranges 0.001 - 0.1 m/s, suggesting the potential for significant interaction of water and solutes with transient storage zones in hillslopes compared to streams. Transient storage, the temporary retention of water and solutes in slow-flowing water, contributes to increased water residence time and thus the exposure of water and associated solutes to biochemically reactive substrates. Seasonal patterns in thaw depth of hillslope soils and discharge from hillslopes in the Arctic suggest that the relative contribution of transient storage zones might show predictable seasonal- and event-scale patterns. We conducted slug injections of a conservative solute (NaCl) in two water tracks in the Kuparuk River watershed, Alaska, during two summers to characterize how transient storage varied with thaw depth and discharge. The resulting break-through curves were separated into three dominant processes using an analytical advection-dispersion model: 1) salt mass primarily moved by advection and dispersion, 2) salt mass experiencing transient storage, and 3) a mass loss term. Across all tracer experiments, the mean percentage of total injected tracer mass associated with transient storage was 54%. This is comparable to a peat-bottomed stream but greater than a cobble-lined channel in a nearby catchment. However, transient storage was variable among experiments (1.3 - 72%). Discharge was also variable across experiments, ranging 0.05 - 3.5 L/s, and there was a negative correlation between transient storage and discharge. Thus, we expect significant interaction of solutes with soils in water tracks during inter-storm periods, when the majority of water moving through water tracks enters transient storage zones. We did not see a

  16. Transient regional osteoporosis

    Directory of Open Access Journals (Sweden)

    F. Trotta

    2011-09-01

    Full Text Available Transient osteoporosis of the hip and regional migratory osteoporosis are uncommon and probably underdiagnosed bone diseases characterized by pain and functional limitation mainly affecting weight-bearing joints of the lower limbs. These conditions are usually self-limiting and symptoms tend to abate within a few months without sequelae. Routine laboratory investigations are unremarkable. Middle aged men and women during the last months of pregnancy or in the immediate post-partum period are principally affected. Osteopenia with preservation of articular space and transitory edema of the bone marrow provided by magnetic resonance imaging are common to these two conditions, so they are also known by the term regional transitory osteoporosis. The appearance of bone marrow edema is not specific to regional transitory osteoporosis but can be observed in several diseases, i.e. trauma, reflex sympathetic dystrophy, avascular osteonecrosis, infections, tumors from which it must be differentiated. The etiology of this condition is unknown. Pathogenesis is still debated in particular the relationship with reflex sympathetic dystrophy, with which regional transitory osteoporosis is often identified. The purpose of the present review is to remark on the relationship between transient osteoporosis of the hip and regional migratory osteoporosis with particular attention to the bone marrow edema pattern and relative differential diagnosis.

  17. Transient congenital hypothyroidism

    Directory of Open Access Journals (Sweden)

    Nisha Bhavani

    2011-01-01

    Full Text Available Transient thyroid function abnormalities in the new born which revert back to normal after varying periods of time are mostly identified in the neonatal screening tests for thyroid and are becoming more common because of the survival of many more premature infants. It can be due to factors primarily affecting the thyroid-like iodine deficiency or excess, maternal thyroid-stimulating hormone receptor (TSHR antibodies, maternal use of antithyroid drugs, DUOX 2 (dual oxidase 2 mutations, and prematurity or those that affect the pituitary-like untreated maternal hyperthyroidism, prematurity, and drugs. Most of these require only observation, whereas some, such as those due to maternal TSHR antibodies may last for upto three-to-six months and may necessitate treatment. Isolated hyperthyrotropinemia (normal Tetraiodothyronine (T4 and high Thyroid Stimulating hormone (TSH may persist as subclinical hypothyroidism in childhood. Transient hypothyroxinemia (low T4 and normal TSH is very common in premature babies. The recognition of these conditions will obviate the risks associated with unnecessary thyroxine supplementation in childhood and parental concerns of a life long illness in their offspring.

  18. Transient osteoporosis of the hip

    International Nuclear Information System (INIS)

    McWalter, Patricia; Hassan Ahmed

    2007-01-01

    Transient osteoporosis of the hip is an uncommon cause of hip pain, mostly affecting healthy middle-aged men and also women in the third trimester of pregnancy. We present a case of transient osteoporosis of the hip in a 33-year-old non-pregnant female patient. This case highlights the importance of considering a diagnosis of transient osteoporosis of the hip in patients who present with hip pain. (author)

  19. Unraveling the physics of nanofluidic phenomena at the single-molecule level

    Energy Technology Data Exchange (ETDEWEB)

    Fornasiero, Francesco [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-10-13

    Despite groundbreaking potential in a broad application space, several nanofluidic phenomena remain poorly understood. Toward advancing the understanding of fluid behavior under nanoscale confinement, we developed a novel, ideal platform for fundamental molecular transport studies, in which the fluidic channel is a single carbon nanotube (CNT). CNTs offer the advantage of simple chemistry and structure, which can be synthetically tuned with nanometer precision and accurately modeled. With combined experimental and computational approaches, we demonstrated that CNT pores with 1-5 nm diameters conduct giant ionic currents that follow an unusual sublinear electrolyte concentration dependence. The large magnitude of the ionic conductance appears to originate from a strong electro-osmotic flow in smooth CNT pores. First-principle simulations suggest that electro-osmotic flow arises from localized negative polarization charges on carbon atoms near a potassium (K+) ion and from the strong cation-graphitic wall interactions, which drive K+ ions much closer to the wall than chlorides (Cl-). Single-molecule translocation studies reveal that charged molecules may be distinguished from neutral species on the basis of the sign of the transient current change during their passage through the nanopore. Together with shedding light on a few controversial questions in the CNT nanofluidics area, these results may benefit LLNL’s Security Mission by providing the foundation for the development of advanced single-molecule detection system for bio/chem/explosive analytes. In addition, these experimental and computational platforms can be applied to advance fundamental knowledge in other fields, from energy storage and membrane separation to superfluid physics.

  20. Transient Go: A Mobile App for Transient Astronomy Outreach

    Science.gov (United States)

    Crichton, D.; Mahabal, A.; Djorgovski, S. G.; Drake, A.; Early, J.; Ivezic, Z.; Jacoby, S.; Kanbur, S.

    2016-12-01

    Augmented Reality (AR) is set to revolutionize human interaction with the real world as demonstrated by the phenomenal success of `Pokemon Go'. That very technology can be used to rekindle the interest in science at the school level. We are in the process of developing a prototype app based on sky maps that will use AR to introduce different classes of astronomical transients to students as they are discovered i.e. in real-time. This will involve transient streams from surveys such as the Catalina Real-time Transient Survey (CRTS) today and the Large Synoptic Survey Telescope (LSST) in the near future. The transient streams will be combined with archival and latest image cut-outs and other auxiliary data as well as historical and statistical perspectives on each of the transient types being served. Such an app could easily be adapted to work with various NASA missions and NSF projects to enrich the student experience.

  1. Successive Bifurcation Conditions of a Lorenz-Type Equation for the Fluid Convection Due to the Transient Thermal Field

    Directory of Open Access Journals (Sweden)

    Xiaoling He

    2007-01-01

    Full Text Available This paper investigates the convection flow between the two parallel plates in a fluid cell subject to the transient thermal field. We use the modal approximations similar to that of the original Lorenz model to obtain a generalized Lorenz-type model for the flow induced by the transient thermal field at the bottom plate. This study examines the convection flow bifurcation conditions in relation to the transient temperature variations and the flow properties. We formulated successive bifurcation conditions and illustrated the various flow behaviors and their steady-state attractors affected by the thermal field functions and fluid properties.

  2. Nonspecific competition underlies transient attention

    NARCIS (Netherlands)

    Wilschut, A.M.; Theeuwes, J.; Olivers, C.N.L.

    2015-01-01

    Cueing a target by abrupt visual stimuli enhances its perception in a rapid but short-lived fashion, an effect known as transient attention. Our recent study showed that when targets are cued at a constant, central location, the emergence of the transient performance pattern was dependent on the

  3. Transients by substructuring with DMAP

    Science.gov (United States)

    Butler, T. G.

    1978-01-01

    Automated substructuring in level 16 of NASTRAN was employed as a preface to the solution of a direct transient analysis. The DMAP ALTER statements written to adapt the substructuring for transient purposes are explained. Data recovery was accomplished with transfer functions. Proof of the success of the method is presented with an application to a missile structure.

  4. Ion Acceleration Inside Foreshock Transients

    Science.gov (United States)

    Liu, Terry Z.; Lu, San; Angelopoulos, Vassilis; Lin, Yu; Wang, X. Y.

    2018-01-01

    Recent observations upstream of Earth's bow shock have revealed that foreshock transients can not only accelerate solar wind ions by reflection at their upstream boundaries but may also accelerate ions inside them. Evidence for the latter comes from comparisons of ion spectra inside and outside the cores, and from evidence of leakage of suprathermal ions from the cores. However, definite evidence for, and the physics of, ion acceleration in the foreshock transients are still open questions. Using case studies of foreshock transients from Time History of Events and Macroscale Interactions during Substorms observations, we reveal an ion acceleration mechanism in foreshock transients that is applicable to 25% of the transients. The ion energy flux is enhanced between several keV to tens of keV in the cores. We show that these energetic ions are reflected at the earthward moving boundary of foreshock transients, are accelerated through partial gyration along the convection electric field, and can leak out both upstream and downstream of the foreshock transients. Using ions moving self-consistently with a generic 3-D global hybrid simulation of a foreshock transient, we confirm this physical picture of ion acceleration and leakage. These accelerated ions could be further accelerated at the local bow shock and repopulate the foreshock, increasing the efficacy of solar wind-magnetosphere interactions.

  5. Pressure transients in pipeline systems

    DEFF Research Database (Denmark)

    Voigt, Kristian

    1998-01-01

    This text is to give an overview of the necessary background to do investigation of pressure transients via simulations. It will describe briefly the Method of Characteristics which is the defacto standard for simulating pressure transients. Much of the text has been adopted from the book Pressur...

  6. Evolution of cerebral blood flow between the acute stage and one month after a global transient amnesia: a study of 18 patients; Evolution des debits sanguins cerebraux entre la phase aigue et un mois apres un ictus amnesique: etude chez 18 patients

    Energy Technology Data Exchange (ETDEWEB)

    Philippon, B.; Houzard, C.; Cinotti, L. [Hopital Neuro Cardiologique, Centre de Medecine Nucleaire, 69 - Lyon (France); Croisile, B. [Hopital Neuro Cardiologique, Lab. de Neuropsychologie, Fonctions Cognitives, Langage et Memoire, 69 - Lyon (France)

    2001-03-01

    We studied 18 patients within 24 hours of an idiopathic transient global amnesia and one month later using {sup 133}Xe et {sup 99m}Tc-HMPAO for CBF measurements. Absolute hemispheric CBF obtained with the {sup 133}Xe were initially: (right) = 46.9 ml/mn/100 g (s.d 6.6) and (left) = 47.9 (s.d 6.8). One month later, a significant increase of the right hemispheric CBF occurred (52.0 {+-} 6.9). Accordingly, absolute CBF increased bilaterally in the cerebellar and temporal regions. Local relative cerebral blood flow ( {sup 99m}Tc-HMPAO) allowed to reinforce these findings with increased resolution. They can also provide quantitative values thanks to the{sup 133}Xe calibration. (authors)

  7. Transient Enhanced Diffusion

    Science.gov (United States)

    Gossmann, Hans-Joachim L.

    1996-03-01

    Ion implantation is the standard method for dopant introduction during integrated circuit manufacturing, determining crucial device characteristics. Implantation creates point-defects, such as Si self-interstitials and vacancies, far in excess of equilibrium concentrations. Since the diffusion of common dopants involves Si point defects, the interaction of damage and dopants during subsequent annealing steps leads to the phenomenon known as "transient enhanced diffusion" (TED): The dopant diffusivities are enhanced, possibly by many orders of magnitude. The enhancement is transient since the intrinsic defects eventually diffuse into the bulk or annihilate at the surface. The desired specific dopant profile of the device is thus the result of a complex reaction, involving the creation of damage and its spatial distribution, diffusion, and interaction of the point defects among themselves and with interfaces and other defects. As device dimensions shrink and experiments become more and more expensive, the capability to predict these kinds of non-equilibrium phenomena accurately becomes crucial to Si technology development. In our experiments to extract physical mechanisms and parameters of TED we use the method of sharp B- and Sb doping spikes to track interstitial and vacancy concentrations as a function of depth during processing. Thus we gain sensitivity to small diffusion distances (low temperatures) and separate the damaged region from the region of the interaction with dopants. In addition, our method yields directly the actual point defect diffusivity. Although an ion implant initially produces Frenkel pairs, Monte-carlo simulations show that the vacancies annihilate quickly. The excess interstitials, roughly one for each implanted ion coalesce into 311defects. The subsequent evaporation of interstitials from 311ś drives TED. Si interstitial diffusion is influenced by carbon-related traps and we will demonstrate that this finding reconciles quantitatively a

  8. DNA translocating through a carbon nanotube can increase ionic current

    International Nuclear Information System (INIS)

    Park, Jae Hyun; Krstić, Predrag S; He Jin; Gyarfas, Brett; Lindsay, Stuart

    2012-01-01

    Translocation of DNA through a narrow, single-walled carbon nanotube can be accompanied by large increases in ion current, recently observed in contrast to the ion current blockade. We use molecular dynamics simulations to show that large electro-osmotic flow can be turned into a large net current via ion-selective filtering by a DNA molecule inside the carbon nanotube. (paper)

  9. Author Details

    African Journals Online (AJOL)

    Dynamic analysis of a Bernoulli-Euler beam via the Laplace transformation technique. Abstract · Vol 10 (2006) - Articles Hydrodynamic dispersion of a reactive solute in Electro-Osmotic flow using quadratic polynomials. Abstract · Vol 11 (2007) - Articles Effect of viscous damping on the response of a finite beam resting on a ...

  10. Electrophoretic deposition of titania nanoparticles: Wet density of ...

    Indian Academy of Sciences (India)

    ... with time and attained the plateau at longer times. The velocity at which particles attach to the deposit, strongly influences its wet density at initial times. However, the effect of electro-osmotic flow is dominant at longer times. The coating with higher wet density had the higher corrosion resistance in Ringer's solution at 37.5 ...

  11. Numerical analysis of finite Debye-length effects in induced-charge electro-osmosis

    DEFF Research Database (Denmark)

    Gregersen, Misha Marie; Andersen, Mathias Bækbo; Soni, G.

    2009-01-01

    For a microchamber filled with a binary electrolyte and containing a flat unbiased center electrode at one wall, we employ three numerical models to study the strength of the resulting induced-charge electro-osmotic (ICEO) flow rolls: (i) a full nonlinear continuum model resolving the double laye...

  12. Phosphorus recovery from sewage sludge by an electrokinetic process

    DEFF Research Database (Denmark)

    Ribeiro, A.B.; Couto, N.; Mateus, E.P.

    be an effective technique for removing contaminants and recover P from SS and/or SSA. The application of a low-level direct current onto the sludge segment results in both electro-osmotic and electro-migration flows, which are able to induce the migration of ions. For this reason it is expected that phosphate...

  13. Forum on unsteady flow - 1985

    International Nuclear Information System (INIS)

    Rothe, P.H.

    1985-01-01

    This book presents the papers given at a conference on fluid flow and hydraulics. Topics considered at the conference included a numerical study of pressure transients in a borehole due to pipe movement, laminar fluid transients in conduits of unconventional shape, water hammer analysis needs in nuclear power plant design, modeling blockage in unsteady slurry flow in conduits, and check valve slamming in a BWR feedwater system following a postulated pipe break

  14. Languages without Borders: TESOL in a Transient World

    Science.gov (United States)

    Nero, Shondel

    2012-01-01

    In today's transient world, where a continual multidirectional flow of people, goods, and services has deterritorialized languages and their users, languages, especially English, are now without borders. In this context, English language teaching (ELT) as a profession is called to a new task. In this article, I examine this task by asking the…

  15. Transient state of matter in hadron and nucleus collisions

    OpenAIRE

    Troshin, S. M.; Tyurin, N. E.

    2006-01-01

    We discuss properties of the specific strongly interacting transient collective state of matter in hadron and nuclei reactions and emphasize similarity in their dynamics. We consider elliptic flow introduced for description of nucleus collisions and discuss its possible behavior in hadronic reactions.

  16. Numerical investigation into entropy generation in a transient ...

    Indian Academy of Sciences (India)

    2Faculty of Military Science, Stellenbosch University, Private Bag X2,. Saldanha 7395, South ... ration in a transient generalized Couette flow of water-based nanofluids containing. Copper (Cu) and Alumina ... 2074. M H Mkwizu et al devices, solar water heating, cooling of electronics, cooling of transformer oil, improving.

  17. Global instabilities and transient growth in Blasius boundary-layer ...

    Indian Academy of Sciences (India)

    We develop a hybrid of computational and theoretical approaches suited to study the fluid–structure interaction (FSI) of a compliant panel, flush between rigid upstream and downstream wall sections, with a Blasius boundary-layer flow. The ensuing linear-stability analysis is focused upon global instability and transient ...

  18. Transient charging and discharging current study in pure PVF and ...

    Indian Academy of Sciences (India)

    Keywords. PVF; PVDF; polyblend; fluoropolymers; transient current. 1. Introduction. If we take a polymer and apply a step field to it, the field interacts with the bound and free charges causing current flow in the external circuit. Generally, this current, known as absorption or charging current, depends on the time elapsed.

  19. Numerical study on transient local entropy generation in pulsating ...

    Indian Academy of Sciences (India)

    to focus on the irreversibility of heat transfer and fluid flow processes, and try to understand ... The main advantage of this approach ... for various periods by using the Fluent CFD code (Fluent 2003). 2. Mathematical model. 2.1 Pipe geometry. In this study, the numerical solution of the transient local entropy generation in ...

  20. Numerical investigation into entropy generation in a transient ...

    Indian Academy of Sciences (India)

    This work investigates the effects of convective cooling on entropy generation in a transient generalized Couette flow of water-based nanofluids containing Copper (Cu) and Alumina (Al2O3) as nanoparticles. Both First and Second Laws of thermodynamics are utilised to analyse the problem. The model partial differential ...

  1. Simultaneous transport of water and solutes under transient ...

    Indian Academy of Sciences (India)

    Simultaneous transport of water and solutes under transient unsaturated flow conditions – A case study. B K Purandara. ∗. , N Varadarajan and B Venkatesh. National Institute of Hydrology, Hard Rock Regional Center, Belgaum 590 001, Karnataka, India. ∗ e-mail: purandarabk@yahoo.com. The imbalance between ...

  2. Applied hydraulic transients

    CERN Document Server

    Chaudhry, M Hanif

    2014-01-01

    This book covers hydraulic transients in a comprehensive and systematic manner from introduction to advanced level and presents various methods of analysis for computer solution. The field of application of the book is very broad and diverse and covers areas such as hydroelectric projects, pumped storage schemes, water-supply systems, cooling-water systems, oil pipelines and industrial piping systems. Strong emphasis is given to practical applications, including several case studies, problems of applied nature, and design criteria. This will help design engineers and introduce students to real-life projects. This book also: ·         Presents modern methods of analysis suitable for computer analysis, such as the method of characteristics, explicit and implicit finite-difference methods and matrix methods ·         Includes case studies of actual projects ·         Provides extensive and complete treatment of governed hydraulic turbines ·         Presents design charts, desi...

  3. Generation of intense transient magnetic fields

    International Nuclear Information System (INIS)

    Benjamin, R.F.

    1983-01-01

    In a laser system, the return current of a laser generated plasma is conducted near a target to subject that target to a magnetic field. The target may be either a small non-fusion object for testing under the magnetic field or a laser-fusion pellet. In the laser-fusion embodiment, the laser-fusion pellet is irradiated during the return current flow and the intense transient magnetic field is used to control the hot electrons thereof to hinder them from striking and heating the core of the irradiated laser-fusion pellet. An emitter, e.g. a microballoon of glass, metal or plastics, is subjected to a laser pulse to generate the plasma from which the return current flows into a wire cage or a coil and then to earth. (author)

  4. The importance of transient flow simulation in the numerical model of the Guarani Aquifer System; Importancia de la formulacion del regimen temporal de flujo en el modelo numerico del Sistema Acuifero Guarani

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, A.; Vives, L.; Rodriguez, L.; Cota, S. D. S.

    2012-11-01

    A regional groundwater flow model under a steady-state regime has been developed within the framework of the Project for the Environmental Protection and Sustainable Development of the Guarani Aquifer System. The model has allowed the comparison of several plausible hypotheses concerning different conceptual models, mainly with regard to alternative hydraulic conductivity zoning. We assess here the influence of the flow regime, either steady-state or temporal, on the magnitude of hydraulic conductivity and the water balance. The response time to various external stresses is also analyzed. The results indicate that the effect of increasing pumping is immediately noticeable close to pumping wells whilst the effect manifests with a lag time, though less intensively, as the distance from the pumping centre increments. The effect of pumping would be imperceptible 300 km away, at least for the simulated conditions in a 100-year scenario. (Author)

  5. Measurement of transient hydrodynamic characteristics of the reactor RA primary cooling system

    International Nuclear Information System (INIS)

    Jovic, L.; Majstorovic, D.; Zeljkovic, I.

    1987-01-01

    Experimental study of transient hydrodynamic characteristics of the research nuclear reactor RA by simultaneous measurements of fluid flow and pressure on several locations of the RA primary coolant system is done. Loss of electric power transient on the main circulation pumps is simulated. measurement methodology, data processing and results of measured data analysis are given. (author)

  6. Electromagnetic transients in power cables

    CERN Document Server

    da Silva, Filipe Faria

    2013-01-01

    From the more basic concepts to the most advanced ones where long and laborious simulation models are required, Electromagnetic Transients in Power Cables provides a thorough insight into the study of electromagnetic transients and underground power cables. Explanations and demonstrations of different electromagnetic transient phenomena are provided, from simple lumped-parameter circuits to complex cable-based high voltage networks, as well as instructions on how to model the cables.Supported throughout by illustrations, circuit diagrams and simulation results, each chapter contains exercises,

  7. Verification and validation of COBRA-SFS transient analysis capability

    International Nuclear Information System (INIS)

    Rector, D.R.; Michener, T.E.; Cuta, J.M.

    1998-05-01

    This report provides documentation of the verification and validation testing of the transient capability in the COBRA-SFS code, and is organized into three main sections. The primary documentation of the code was published in September 1995, with the release of COBRA-SFS, Cycle 2. The validation and verification supporting the release and licensing of COBRA-SFS was based solely on steady-state applications, even though the appropriate transient terms have been included in the conservation equations from the first cycle. Section 2.0, COBRA-SFS Code Description, presents a capsule description of the code, and a summary of the conservation equations solved to obtain the flow and temperature fields within a cask or assembly model. This section repeats in abbreviated form the code description presented in the primary documentation (Michener et al. 1995), and is meant to serve as a quick reference, rather than independent documentation of all code features and capabilities. Section 3.0, Transient Capability Verification, presents a set of comparisons between code calculations and analytical solutions for selected heat transfer and fluid flow problems. Section 4.0, Transient Capability Validation, presents comparisons between code calculations and experimental data obtained in spent fuel storage cask tests. Based on the comparisons presented in Sections 2.0 and 3.0, conclusions and recommendations for application of COBRA-SFS to transient analysis are presented in Section 5.0

  8. Transient forced convection heat transfer in helium gas

    International Nuclear Information System (INIS)

    Liu, Qiusheng; Fukuda, Katsuya

    2002-01-01

    The knowledge of transient forced convection heat transfer at various periods of exponential increase of heat input to a heater is important as a database for understanding the transient heat transfer process in a high temperature gas cooled reactor (HTGR) due to an accident in excess reactivity. The transient heat transfer coefficients for forced convection flow of helium gas over a horizontal cylinder were measured using a forced convection test loop. The platinum heater with a diameter of 1.0 mm was heated by electric current with an exponential increase of Q 0 exp(t/τ). It was clarified that the heat transfer coefficient approaches the quasi-steady-state one for the period τ over 1 s, and it becomes higher for the period of τ shorter than 1 s. The transient heat transfer shows less dependent on the gas flowing velocity when the period becomes very shorter. Semi-empirical correlations for quasi-steady-state and transient heat transfer were developed based on the experimental data. (author)

  9. An analytical and experimental investigation of natural circulation transients in a model pressurized water reactor

    International Nuclear Information System (INIS)

    Massoud, M.

    1987-01-01

    Natural Circulation phenomena in a simulated PWR was investigated experimentally and analytically. The experimental investigation included determination of system characteristics as well as system response to the imposed transient under symmetric and asymmetric operations. System characteristics were used to obtain correlation for heat transfer coefficient in heat exchangers, system flow resistance, and system buoyancy heat. Asymmetric transients were imposed to study flow oscillation and possible instability. The analytical investigation encompassed development of mathematical model for single-phase, steady-state and transient natural circulation as well as modification of existing model for two-phase flow analysis of phenomena such as small break LOCA, high pressure coolant injection and pump coast down. The developed mathematical model for single-phase analysis was computer coded to simulate the imposed transients. The computer program, entitled ''Symmetric and Asymmetric Analysis of Single-Phase Flow (SAS),'' were employed to simulate the imposed transients. It closely emulated the system behavior throughout the transient and subsequent steady-state. Modifications for two-phase flow analysis included addition of models for once-through steam generator and electric heater rods. Both programs are faster than real time. Off-line, they can be used for prediction and training applications while on-line they serve for simulation and signal validation. The programs can also be used to determine the sensitivity of natural circulation behavior to variation of inputs such as secondary distribution and power transients

  10. An analytical and experimental investigation of natural circulation transients in a model pressurized water reactor

    Energy Technology Data Exchange (ETDEWEB)

    Massoud, M

    1987-01-01

    Natural Circulation phenomena in a simulated PWR was investigated experimentally and analytically. The experimental investigation included determination of system characteristics as well as system response to the imposed transient under symmetric and asymmetric operations. System characteristics were used to obtain correlation for heat transfer coefficient in heat exchangers, system flow resistance, and system buoyancy heat. Asymmetric transients were imposed to study flow oscillation and possible instability. The analytical investigation encompassed development of mathematical model for single-phase, steady-state and transient natural circulation as well as modification of existing model for two-phase flow analysis of phenomena such as small break LOCA, high pressure coolant injection and pump coast down. The developed mathematical model for single-phase analysis was computer coded to simulate the imposed transients. The computer program, entitled ''Symmetric and Asymmetric Analysis of Single-Phase Flow (SAS),'' were employed to simulate the imposed transients. It closely emulated the system behavior throughout the transient and subsequent steady-state. Modifications for two-phase flow analysis included addition of models for once-through steam generator and electric heater rods. Both programs are faster than real time. Off-line, they can be used for prediction and training applications while on-line they serve for simulation and signal validation. The programs can also be used to determine the sensitivity of natural circulation behavior to variation of inputs such as secondary distribution and power transients.

  11. Empirical method to calculate Clinch River Breeder Reactor (CRBR) inlet plenum transient temperatures

    International Nuclear Information System (INIS)

    Howarth, W.L.

    1976-01-01

    Sodium flow enters the CRBR inlet plenum via three loops or inlets. An empirical equation was developed to calculate transient temperatures in the CRBR inlet plenum from known loop flows and temperatures. The constants in the empirical equation were derived from 1/4 scale Inlet Plenum Model tests using water as the test fluid. The sodium temperature distribution was simulated by an electrolyte. Step electrolyte transients at 100 percent model flow were used to calculate the equation constants. Step electrolyte runs at 50 percent and 10 percent flow confirmed that the constants were independent of flow. Also, a transient was tested which varied simultaneously flow rate and electrolyte. Agreement of the test results with the empirical equation results was good which verifies the empirical equation

  12. CHARACTERIZATION OF TRANSIENT PUFF EMISSIONS ...

    Science.gov (United States)

    Symposium Paper Transient puff emissions were characterized from burning carpet charges that were fed to a pilotscale rotary kiln combustor to assess the potential impact on emissions of using post-consumer carpet as an alternative fuel in cement kilns.

  13. Transient heating of moving objects

    Directory of Open Access Journals (Sweden)

    E.I. Baida

    2014-06-01

    Full Text Available A mathematical model of transient and quasistatic heating of moving objects by various heat sources is considered. The mathematical formulation of the problem is described, examples of thermal calculation given.

  14. Transient stability of superconducting alternators

    International Nuclear Information System (INIS)

    Furuyama, M.; Kirtley, J.L. Jr.

    1975-01-01

    A simulation study is performed for the purpose of determining the transient stability characteristics of superconducting alternators. This simulation is compared with an equal area criterion method. It is found that superconducting machines have good transient stability characteristics, that field forcing is not particularly helpful nor necessary. It is also found that the equal area criterion is useful for computing critical clearing times, if voltage behind subtransient reactance is held constant. (U.S.)

  15. Transient behaviour of main coolant pump in nuclear power plants

    International Nuclear Information System (INIS)

    Delja, A.

    1986-01-01

    A basic concept of PWR reactor coolant pump thermo-hydraulic modelling in transient and accident operational condition is presented. The reactor coolant pump is a component of the nuclear steam supply system which forces the coolant through the reactor and steam generator, maintaining design heat transfer condition. The pump operating conditions have strong influence on the flow and thermal behaviour of NSSS, both in the stationary and nonstationary conditions. A mathematical model of the reactor coolant pump is formed by using dimensionless homologous relations in the four-quadrant regimes: normal pump, turbine, dissipation and reversed flow. Since in some operational regimes flow of mixture, liquid and steam may occur, the model has additional correction members for two-phase homologous relations. Modular concept has been used in developing computer program. The verification is performed on the simulation loss of offsite power transient and obtained results are presented. (author)

  16. Analysis of short-term reactor cavity transient

    International Nuclear Information System (INIS)

    Cheng, T.C.; Fischer, S.R.

    1981-01-01

    Following the transient of a hypothetical loss-of-coolant accident (LOCA) in a nuclear reactor, peak pressures are reached within the first 0.03 s at different locations inside the reactor cavity. Due to the complicated multidimensional nature of the reactor cavity, the short-term analysis of the LOCA transient cannot be performed by using traditional containment codes, such as CONTEMPT. The advanced containment code, BEACON/MOD3, developed at the Idaho National Engineering Laboratory (INEL), can be adapted for such analysis. This code provides Eulerian, one and two-dimensional, nonhomogeneous, nonequilibrium flow modeling as well as lumped parameter, homogeneous, equilibrium flow modeling for the solution of two-component, two-phase flow problems. The purpose of this paper is to demonstrate the capability of the BEACON code to analyze complex containment geometry such as a reactor cavity

  17. FFTF fuel pin design procedure verification for transient operation

    International Nuclear Information System (INIS)

    Baars, R.E.

    1975-05-01

    The FFTF design procedures for evaluating fuel pin transient performance are briefly reviewed, and data where available are compared with design procedure predictions. Specifically, burst conditions derived from Fuel Cladding Transient Tester (FCTT) tests and from ANL loss-of-flow tests are compared with burst pressures computed using the design procedure upon which the cladding integrity limit was based. Failure times are predicted using the design procedure for evaluation of rapid reactivity insertion accidents, for five unterminated TREAT experiments in which well characterized fuel failures were deliberately incurred. (U.S.)

  18. An investigation of loads generated by temperature transients in pipes

    International Nuclear Information System (INIS)

    Maneschy, C.E.

    1988-12-01

    An analysis is presented of the effect of a transient temperature on the stress distribution due to a fluid flowing through a pipe, is analytically determined using the definition of a variable called in this paper as ''shifted time''. This variable, which is related to the axial coordinate, the average fluid velocity and the real time, is defined to make the transient thermal problem one-dimensional. The stresses are then calculated from the temperature solution using the linear theory of viscoelasticity. (author) [pt

  19. Thermal-hydraulic calculation methods for transients and accidents of the reactor cooling system under special consideration of multi-dimensional flows (ATHLET, FLUBOX, CFX). Final report; Thermohydraulische Rechenmethoden zu Transienten und Stoerfaellen im Reaktorkuehlkreislauf unter besonderer Beruecksichtigung mehrdimensionaler Stroemungen (ATHLET, FLUBOX, CFX). Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Glaeser, H.; Graf, U.; Herb, J.; and others

    2012-02-15

    The project RS1184 „Thermal-hydraulic Calculation Methods for Transients and Accidents of the Reactor Cooling System Under Special Consideration of Multi-Dimensional Flows (ATHLET, FLUBOX, CFX)'' consists of four work packages: 1. Further development of the computer code ATHLET 2. Termination of FLUBOX development and development of an ATHLET-internal 3D module 3. Coupling of ATHLET and CFD code ANSYS CFX as well as CFX model development to simulate three-dimensional flows in the reactor coolant system 4. Prediction capability of computer code ATHLET. One of the superior objectives of the project is to improve the prediction capability of the thermal-hydraulic system code ATHLET, including the simulation of multi-dimensional flow in the reactor vessel. The constitutive equations in ATHLET, especially the momentum equations in ATHLET, are written in one-dimensional form. It was planned to develop the 2D/3D module FLUBOX further and couple it with ATHLET. Due to reasons given in chapter 3, the FLUBOX development was terminated. Instead, the decision was made to develop a fast running internal ATHLET-module. The 2D/3D equations for ATHLET have been derived and were implemented. That strategy allows using all ATHLET models and the ATHLET code structure. An additional advantage is that different numerical schemes of different codes, and consequently a loss of efficiency, will be avoided. A second possibility is the coupling of ATHLET with the CFD code ANSYS CFX. Such a coupled code system will be used in those cases when a part of the simulation area is needed to be calculated with high resolution. Such a detailed modelling cannot be provided by ATHLET-3D. A complete representation of the cooling system by a CFD code cannot be performed due to calculation time. In order to calculate the complete system behavior still with ATHLET, that part to be investigated in more detail, will be replaced by a CFX model. Several new models and improvements of existing

  20. Three dimensional CFD analysis of transient compressible flows around a train passing through a tunnel; Tunnel nai ressha sokoji no nagare no suchi kaiseki to jissoku kekka tono hikaku

    Energy Technology Data Exchange (ETDEWEB)

    Otsuyama, S. [West Japan Railway Company, Osaka (Japan); Yang, X. [Kanazawa University, Ishikawa (Japan); Okajima, A. [Kanazawa University, Ishikawa (Japan). Faculty of Engineering

    1999-11-25

    Three dimensional computations were performed using the KIVA-3 code to investigate the unsteady compressible turbulent flows about a practical train passing through a single-track tunnel. Both length of the train/tunnel and speed of the train were considered to investigate their effects on the train-tunnel interaction. In order to understand the whole process of the train-tunnel aerodynamic interaction, we studied the formation and propagation of the pressure waves, the reflection and radiation of the waves at the tunnel portals and the histories of aerodynamic forces on the train. The experimental results were compared well with the computational data. The code can be used to predict the aerodynamic phenomena of the train-tunnel system. (author)

  1. COBRA-WC model and predictions for a fast-reactor natural-circulation transient

    International Nuclear Information System (INIS)

    George, T.L.; Basehore, K.L.; Prather, W.A.

    1980-01-01

    The COBRA-WC (Whole Core) code has been used to predict the core-wide coolant and rod temperature distribution in a liquid metal fast reactor during the early part (first 220 seconds) of a natural circulation transient. Approximately one-sixth of the core was modeled including bypass flows and the pressure losses above and below the core region. Detailed temperature and flow distributions were obtained for the two test fuel assemblies. The COBRA-WC model, the approach, and predictions of core-wide transient coolant and rod temperatures during a natural circulation transient are presented in this paper

  2. Reactor operational transient analysis

    International Nuclear Information System (INIS)

    Shin, W.K.; Chae, S.K.; Han, K.I.; Yang, K.S.; Chung, H. D.; Kim, H.G.; Moon, H.J.; Ryu, Y.H.

    1983-01-01

    To build up efficient capability of safety review and inspection for the nuclear power plants, four area of studies have performed as follows: 1) In order to search the most optimized operating method during load follow operating schemes, automatic control and normal control, are compared each other under the CAOC condition. The analysis performed by DDID code has shown that the reactor has to be controlled by the operator manually during load follow operation. 2) Through the sensitivity analysis by COBRA code, the operating parameters, such as coolant pressure, flow rate, inlet temperature, and power distribution are shown to be important to the determination of DNBR. Expecially, inlet temperature of primary coolant system is appeared as the most senstive parameter on DNBR. 3) FRAPCON code is adapted to study the sensitivity of several operational parameters on the mechanical properties of reactor fuel rod. 4) The calculations procedure which is required to be obtained the neutron fluence at the reactor vessel and the spectrum at the surveillance capsule is established. The results of computation are conpared with those of FSAR and SWRI report and proved its applicability to reactor surveillance program. (Author)

  3. Preliminary analysis of typical transients in fusion driven subcritical system (FDS-I)

    International Nuclear Information System (INIS)

    Bai Yunqing; Ke Yan; Wu Yican

    2007-01-01

    The potential safety characteristic is expected as one of the advantages of fusion-driven subcritical system (FDS-I) for the transmutation and incineration of nuclear waste compared with the critical reactor. Transients of the FDS-I may occur due to the perturbation of external neutron source, the failure of functional device, and the occurrence of the uncontrolled event. As typical transient scenarios, the following cases were analyzed: unprotected plasma overpower (UPOP), unprotected loss of flow (ULOF), unprotected transient overpower (UTOP). The transient analyses for the FDS-I were performed with a coupled two-dimensional thermal-hydraulics and neutronics transient analysis code NTC2D. The negative feedback of reactivity is the interesting safety feature of FDS-I as temperature increase, due to the fuel form of the circulating particle. The present simulation results showed that the current FDS-I design has a resistance against severe transient scenarios. (author)

  4. A study of forced convective boiling heat transfer under power transients

    International Nuclear Information System (INIS)

    Kataoka, Isao; Serizawa, Akimi; Sakurai, Akira

    1984-01-01

    Experimental investigation has been carried out on forced convective boiling heat transfer under exponentially increasing heat generation rate using Platinum wire heater located parrallel to flow direction. Effects of inlet velocity, subcooling, pressure, exponential period and heater geometry on the transient boiling have been examined. Two types of transient boiling are observed. In one type, the transient boiling curve coincides with steady-state boiling curve and/or its extrapolation (A-type) while in the other type the transient boiling curve does not show the coincidence (B-type). Transient maximum heat flux increases with increasing velocity, subcooling, pressure and with decreasing exponential period for A-type boiling. Finally, the experimental correlation has been obtained for the transient maximum heat flux. (author)

  5. Recent development of transient electronics

    Directory of Open Access Journals (Sweden)

    Huanyu Cheng

    2016-01-01

    Full Text Available Transient electronics are an emerging class of electronics with the unique characteristic to completely dissolve within a programmed period of time. Since no harmful byproducts are released, these electronics can be used in the human body as a diagnostic tool, for instance, or they can be used as environmentally friendly alternatives to existing electronics which disintegrate when exposed to water. Thus, the most crucial aspect of transient electronics is their ability to disintegrate in a practical manner and a review of the literature on this topic is essential for understanding the current capabilities of transient electronics and areas of future research. In the past, only partial dissolution of transient electronics was possible, however, total dissolution has been achieved with a recent discovery that silicon nanomembrane undergoes hydrolysis. The use of single- and multi-layered structures has also been explored as a way to extend the lifetime of the electronics. Analytical models have been developed to study the dissolution of various functional materials as well as the devices constructed from this set of functional materials and these models prove to be useful in the design of the transient electronics.

  6. Transient Faults in Computer Systems

    Science.gov (United States)

    Masson, Gerald M.

    1993-01-01

    A powerful technique particularly appropriate for the detection of errors caused by transient faults in computer systems was developed. The technique can be implemented in either software or hardware; the research conducted thus far primarily considered software implementations. The error detection technique developed has the distinct advantage of having provably complete coverage of all errors caused by transient faults that affect the output produced by the execution of a program. In other words, the technique does not have to be tuned to a particular error model to enhance error coverage. Also, the correctness of the technique can be formally verified. The technique uses time and software redundancy. The foundation for an effective, low-overhead, software-based certification trail approach to real-time error detection resulting from transient fault phenomena was developed.

  7. Cohabitation Duration and Transient Domesticity.

    Science.gov (United States)

    Golub, Andrew; Reid, Megan; Strickler, Jennifer; Dunlap, Eloise

    2013-01-01

    Research finds that many impoverished urban Black adults engage in a pattern of partnering and family formation involving a succession of short cohabitations yielding children, a paradigm referred to as transient domesticity. Researchers have identified socioeconomic status, cultural adaptations, and urbanicity as explanations for aspects of this pattern. We used longitudinal data from the 2001 Survey of Income and Program Participation to analyze variation in cohabitation and marriage duration by race/ethnicity, income, and urban residence. Proportional hazards regression indicated that separation risk is greater among couples that are cohabiting, below 200% of the federal poverty line, and Black but is not greater among urban dwellers. This provides empirical demographic evidence to support the emerging theory of transient domesticity and suggests that both socioeconomic status and race explain this pattern. We discuss the implications of these findings for understanding transient domesticity and make recommendations for using the Survey of Income and Program Participation to further study this family formation paradigm.

  8. Explosive and Radio-Selected Transients: Transient Astronomy with ...

    Indian Academy of Sciences (India)

    Therefore, multiwaveband observational efforts with wide fields of view will be the key to progress of transients astronomy from the middle 2020s offering unprecedented deep images and high spatial and spectral resolutions. Radio observations of Gamma Ray Bursts (GRBs) with SKA will uncover not only much fainter ...

  9. Transient analysis of multicavity klystrons

    International Nuclear Information System (INIS)

    Lavine, T.L.; Miller, R.H.; Morton, P.L.; Ruth, R.D.

    1988-09-01

    We describe a model for analytic analysis of transients in multicavity klystron output power and phase. Cavities are modeled as resonant circuits, while bunching of the beam is modeled using linear space-charge wave theory. Our analysis has been implemented in a computer program which we use in designing multicavity klystrons with stable output power and phase. We present as examples transient analysis of a relativistic klystron using a magnetic pulse compression modulator, and of a conventional klystron designed to use phase shifting techniques for RF pulse compression. 4 refs., 4 figs

  10. Response of dairy cattle to transient voltages and magnetic fields

    International Nuclear Information System (INIS)

    Reinemann, D.J.; Laughlin, N.K.; Stetson, L.E.

    1995-01-01

    Stray voltages in dairy facilities have been studied since the 1970's. Previous research using steady-state ac and dc voltages has defined cow-contact voltage levels which may cause behavior and associated production problems. This research was designed to address concerns over possible effects of transient voltages and magnetic fields on dairy cows. Dairy cows response to transient voltages and magnetic fields was measured. The waveforms of the transient voltages applied were: 5 cycles of 60-Hz ac with a total pulse time of 83 ms, 1 cycle of 60-Hz ac with a total pulse time of 16 ms, and 1 cycle of an ac square wave (spiking positive and negative) of 2-ms duration. Alternating magnetic fields were produced by passing 60-Hz ac fundamental frequency with 2nd and 3rd harmonic and random noise components in metal structures around the cows. The maximum magnetic field associated with this current flow was in excess of 4 G. A wide range of sensitivity to transient voltages was observed among cows. Response levels from 24 cows to each transient exposure were normally distributed. No responses to magnetic fields were observed

  11. Structural evaluation of electrosleeved tubes under severe accident transients

    International Nuclear Information System (INIS)

    Majumdar, S.

    1999-01-01

    A flow stress model was developed for predicting failure of Electrosleeved PWR steam generator tubing under severe accident transients. The Electrosleeve, which is nanocrystalline pure nickel, loses its strength at temperatures greater than 400 C during severe accidents because of grain growth. A grain growth model and the Hall-Petch relationship were used to calculate the loss of flow stress as a function of time and temperature during the accident. Available tensile test data as well as high temperature failure tests on notched Electrosleeved tube specimens were used to derive the basic parameters of the failure model. The model was used to predict the failure temperatures of Electrosleeved tubes with axial cracks in the parent tube during postulated severe accident transients

  12. TRAWA, a transient analysis code for water reactions

    International Nuclear Information System (INIS)

    Rajamaeki, M.

    1976-06-01

    TRAWA is a transient analysis code for water reactors. It solves the two-group neutron diffusion equations simultaneously with the heat conduction equations and the two-phase hydraulic equations for one or more channels. At most one-dimensional submodels are used. Neither thermal nor hydraulic mixing appear between channels. Doppler, coolant density, coolant temperature, and soluble poison density feedbacks due to the thermohydraulics of the channels are described by using polynomial expansions for the group constants. The hydraulic circuit outside the reactor core consists of by-pass channel and risers with two-phase flow and of pump lines with incompressible flow. Nontrivial implicit methods are employed in the discretization of the equations to allow for sparse spatial mesh and flexible choice of time steps. Various transients can be calculated by applying external disturbances. The code is extensively supplied by input and output capabilities. TRAWA is written in FORTRAN V for UNIVAC 1108 computer. (author)

  13. SCORE-EVET: a computer code for the multidimensional transient thermal-hydraulic analysis of nuclear fuel rod arrays

    International Nuclear Information System (INIS)

    Benedetti, R.L.; Lords, L.V.; Kiser, D.M.

    1978-02-01

    The SCORE-EVET code was developed to study multidimensional transient fluid flow in nuclear reactor fuel rod arrays. The conservation equations used were derived by volume averaging the transient compressible three-dimensional local continuum equations in Cartesian coordinates. No assumptions associated with subchannel flow have been incorporated into the derivation of the conservation equations. In addition to the three-dimensional fluid flow equations, the SCORE-EVET code ocntains: (a) a one-dimensional steady state solution scheme to initialize the flow field, (b) steady state and transient fuel rod conduction models, and (c) comprehensive correlation packages to describe fluid-to-fuel rod interfacial energy and momentum exchange. Velocity and pressure boundary conditions can be specified as a function of time and space to model reactor transient conditions such as a hypothesized loss-of-coolant accident (LOCA) or flow blockage

  14. Transient analysis for a system with a tilted disc check valve

    International Nuclear Information System (INIS)

    Jeung, Jaesik; Lee, Kyukwang; Cho, Daegwan

    2014-01-01

    Check valves are used to prevent reverse flow conditions in a variety of systems in nuclear power plants. When a check valve is closed by a reverse flow, the transient load can jeopardize the structural integrity on the piping system and its supports. It may also damage intended function of the in-line components even though the severity of the load differs and depends strongly on types of the check valves. To incorporate the transient load in the piping system, it is very important to properly predict the system response to transients such as a check valve closure accompanied by pump trip and to evaluate the system transient. The one-dimensional transient simulation codes such as the RELAP5/MOD3.3 and TRACE were used. There has not been a single model that integrates the two codes to handle the behavior of a tilted disc check valve, which is designed to mitigate check valve slams by shorting the travel of the disc. In this paper a model is presented to predict the dynamic motion of a tilted disc check valve in the transient simulation using the RELAP5/MOD3.3 code and the model is incorporated in a system transient analysis using control variables of the code. In addition, transient analysis for Essential Service Water (ESW) system is performed using the proposed model and the associated load is evaluated for the system. (author)

  15. Fuel rod behaviour during transients

    International Nuclear Information System (INIS)

    Hughes, H.; Haste, T.J.; Cameron, R.F.; Sinclair, J.E.

    1982-04-01

    The fuel pin performance code SLEUTH, the transient codes FRAP-T5 and TRAFIC and the clad deformation code CANSWEL-2 are described. It is shown how the codes treat gas release, pin cooling, cladding deformation and interaction, gap conductance etc. The materials properties used are indicated. (author)

  16. Charging transient in polyvinyl formal

    Indian Academy of Sciences (India)

    Unknown

    401–406. © Indian Academy of Sciences. 401. Charging transient in polyvinyl formal. P K KHARE*, P L JAIN† and R K PANDEY‡. Department of Postgraduate Studies & Research in Physics & Electronics, Rani Durgavati University,. Jabalpur 482 001, India. †Department of Physics, Government PG College, Damoh 470 ...

  17. Transient interactions between photosynthetic proteins

    NARCIS (Netherlands)

    Hulsker, Rinske

    2008-01-01

    The biological processes that are the basis of all life forms are mediated largely by protein-protein interactions. The protein complexes involved in these interactions can be categorised by their affinity, which results in a range from static to transient complexes. Electron transfer complexes,

  18. Simulation Model of a Transient

    DEFF Research Database (Denmark)

    Jauch, Clemens; Sørensen, Poul; Bak-Jensen, Birgitte

    2005-01-01

    This paper describes the simulation model of a controller that enables an active-stall wind turbine to ride through transient faults. The simulated wind turbine is connected to a simple model of a power system. Certain fault scenarios are specified and the turbine shall be able to sustain operati...

  19. Transient anisotropic magnetic field calculation

    International Nuclear Information System (INIS)

    Jesenik, Marko; Gorican, Viktor; Trlep, Mladen; Hamler, Anton; Stumberger, Bojan

    2006-01-01

    For anisotropic magnetic material, nonlinear magnetic characteristics of the material are described with magnetization curves for different magnetization directions. The paper presents transient finite element calculation of the magnetic field in the anisotropic magnetic material based on the measured magnetization curves for different magnetization directions. For the verification of the calculation method some results of the calculation are compared with the measurement

  20. Transient filament stretching rheometer II

    DEFF Research Database (Denmark)

    Kolte, Mette Irene; Rasmussen, Henrik K.; Hassager, Ole

    1997-01-01

    The Lagrangian sspecification is used to simulate the transient stretching filament rheometer. Simulations are performed for dilute PIB-solutions modeled as a four mode Oldroyd-B fluid and a semidilute PIB-solution modeled as a non-linear single integral equation. The simulations are compared...

  1. Transient Euler-Lagrange/DEM simulation of stent thrombosis

    Directory of Open Access Journals (Sweden)

    Stiehm Michael

    2016-09-01

    Full Text Available Stent implantation is the treatment of choice for cardiovascular diseases. By introduction of biodegradable thick strut stents investigations of thrombosis formation is one focus of research. This study deals with a transient Euler-Lagrange/DEM approach to simulate the flow field, platelet movement and clotting. The recirculation zones prolong particle residence time. As a result, the vicinity of stent struts shown a particularly higher risk for stent thrombosis.

  2. [Transient amnesia in the elderly].

    Science.gov (United States)

    Sellal, François

    2006-03-01

    The two main aetiologies of transient amnesia in the elderly are idiopathic transient global amnesia (TGA) and iatrogenic or toxic amnesia. Vascular and epileptic amnesia are less common. According to the literature, transient psychogenic amnesia, which is a frequent cause of amnesia at age 30 to 50, is very rare in the elderly. TGA is the prototypical picture of transient amnesia. It occurs more often after age 50, with no identified cause, even if some authors accept emotional stress or minor head trauma as occasional precipitants. The mechanism of TGA remains a matter of discussion. It may be the consequence of a spreading depression similar to that described in migraine with aura, but other arguments support an ischemic mechanism. Iatrogenic amnesias are mainly caused by benzodiazepines (BZs) or anticholinergics. The former may occur in a non-anxious subject, who is not a usual consumer of BZ and takes a single dose. The latter are more often due to a hypersensitivity to anticholinergic drugs, in particular in patients presenting with a covert, incipient Alzheimer's disease. A vascular origin must be considered when amnesia is accompanied by other neurological symptoms, and when the regression of the amnesic disorder is slow, lasting several days. It results from lesions involving various mechanisms and locations, mainly subcortical. Partial seizures, most often mesio-temporal, more rarely frontal, may be the cause of transient amnesia in the elderly, in the absence of a past history of epilepsy. The red flag supportive of an epileptic origin is the repetition of stereotyped amnesic episodes. EEG demonstration of seizures may be difficult and the response to antiepileptic drugs effective on partial seizures is usually good.

  3. TRAB, a transient analysis program for BWR. Part 1

    International Nuclear Information System (INIS)

    Rajamaeki, Markku.

    1980-03-01

    TRAB is a transient analysis program for BWR. The present report describes its principles. The program has been developed from TRAWA-program. It models the interior of the pressure vessel and related subsystems of BWR viz. reactor core, recirculation loop including the upper part of the vessel, recirculation pumps, incoming and outgoing flow systems, and control and protection systems. Concerning core phenomena and all flow channel hydraulics the submodels are one-dimensional of main features. The geometry is very flexible. The program has been made particularly to simulate various reactivity transients, but it is applicable more generally to reactor incidents and accidents in which no flow reversal or no emptying of the circuit must occur below the water level. The program is extensively supplied by input and output capabilities. The user can act upon the simulation of a transient by defining external disturbances, scheduled timevariations for any system variable, by modeling new subsystems, which are representable with ordinary linear differential equations, and by defining relations of functional form between system variables. The run of the program can be saved and restarted. (author)

  4. Momentum integral network method for thermal-hydraulic transient analysis

    International Nuclear Information System (INIS)

    Van Tuyle, G.J.

    1983-01-01

    A new momentum integral network method has been developed, and tested in the MINET computer code. The method was developed in order to facilitate the transient analysis of complex fluid flow and heat transfer networks, such as those found in the balance of plant of power generating facilities. The method employed in the MINET code is a major extension of a momentum integral method reported by Meyer. Meyer integrated the momentum equation over several linked nodes, called a segment, and used a segment average pressure, evaluated from the pressures at both ends. Nodal mass and energy conservation determined nodal flows and enthalpies, accounting for fluid compression and thermal expansion

  5. Transient void fraction measurements in rod bundle geometries

    International Nuclear Information System (INIS)

    Chan, A.M.C.

    1998-01-01

    A new gamma densitometer with a Ba-133 source and a Nal(TI) scintillator operated in the count mode has been designed for transient void fraction measurements in the RD-14M heated channels containing a seven-element heater bundle. The device was calibrated dynamically in the laboratory using an air-water flow loop. The void fraction measured was found to compare well with values obtained using the trapped-water method. The device was also found to follow very well the passage of air slugs in pulsating flow with slug passing frequencies of up to about 1.5 hz. (author)

  6. PUMP: analog-hybrid reactor coolant hydraulic transient model

    International Nuclear Information System (INIS)

    Grandia, M.R.

    1976-03-01

    The PUMP hybrid computer code simulates flow and pressure distribution; it is used to determine real time response to starting and tripping all combinations of PWR reactor coolant pumps in a closed, pressurized, four-pump, two-loop primary system. The simulation includes the description of flow, pressure, speed, and torque relationships derived through pump affinity laws and from vendor-supplied pump zone maps to describe pump dynamic characteristics. The program affords great flexibility in the type of transients that can be simulated

  7. Simulation of the turbine discharge transient with the code Trace

    International Nuclear Information System (INIS)

    Mejia S, D. M.; Filio L, C.

    2014-10-01

    In this paper the results of the simulation of the turbine discharge transient are shown, occurred in Unit 1 of nuclear power plant of Laguna Verde (NPP-L V), carried out with the model of this unit for the best estimate code Trace. The results obtained by the code Trace are compared with those obtained from the Process Information Integral System (PIIS) of the NPP-L V. The reactor pressure, level behavior in the down-comer, steam flow and flow rate through the recirculation circuits are compared. The results of the simulation for the operation power of 2027 MWt, show concordance with the system PIIS. (Author)

  8. Study of transient behavior of finned coil heat exchangers

    Science.gov (United States)

    Rooke, S. P.; Elissa, M. G.

    1993-01-01

    The status of research on the transient behavior of finned coil cross-flow heat exchangers using single phase fluids is reviewed. Applications with available analytical or numerical solutions are discussed. Investigation of water-to-air type cross-flow finned tube heat exchangers is examined through the use of simplified governing equations and an up-wind finite difference scheme. The degenerate case of zero air-side capacitance rate is compared with available exact solution. Generalization of the numerical model is discussed for application to multi-row multi-circuit heat exchangers.

  9. Transient motion of hypersonic vehicles including time history effects

    Science.gov (United States)

    Hui, W. H.; Van Roessel, H. J.

    1985-01-01

    An analytic method is developed for calculating the transient pitching motion of a wedge in hypersonic flow, taking into account fully the interaction between its motion and the unsteady air flow passing it. The effects of past motion history on the present state of motion are shown to be caused by the wave reflection from the bow shock. In the Newtonian limit they are equivalent to that of an added moment of inertia. The time history effects generally tend to decrease the damping, rendering the oscillatory motion more persistent. Numerical examples are given.

  10. Nuclear power plant transients: where are we

    International Nuclear Information System (INIS)

    Majumdar, D.

    1984-05-01

    This document is in part a postconference review and summary of the American Nuclear Society sponsored Anticipated and Abnormal Plant Transients in Light Water Reactors Conference held in Jackson, Wyoming, September 26-29, 1983, and in part a reflection upon the issues of plant transients and their impact on the viability of nuclear power. This document discusses state-of-the-art knowledge, deficiencies, and future directions in the plant transients area as seen through this conference. It describes briefly what was reported in this conference, emphasizes areas where it is felt there is confidence in the nuclear industry, and also discusses where the experts did not have a consensus. Areas covered in the document include major issues in operational transients, transient management, transient events experience base, the status of the analytical tools and their capabilities, probabilistic risk assessment applications in operational transients, and human factors impact on plant transients management

  11. Comparative Calculational Study Of The Transient Behaviour Of LBE- And Gas-Cooled Experimental Accelerator-Driven Systems

    Energy Technology Data Exchange (ETDEWEB)

    Mikityuk, K.; Coddington, P.; Bubelis, E

    2005-03-01

    A comparison of transient calculations is given for two 80-MWt MOX-fuelled Experimental Accelerator-Driven Systems (XADS), one cooled by lead-bismuth eutectic and the other by helium. Results obtained with the TRAC/AAA code are presented for protected and unprotected transient overpower, spurious beam trip, loss of flow, and loss of coolant accidents. (author)

  12. Fast thermal transients on valve

    International Nuclear Information System (INIS)

    Ferjancic, M.; Stok, B.; Halilovic, M.; Koc, P.; Mole, N.; Otrin, Z.; Kotar, A.

    2007-01-01

    One of the regulatory body methods to supervise nuclear safety of a nuclear power plant is a review of plant modifications and evaluation of their impact on plant operating experience. The Slovenian Nuclear Safety Administration (SNSA) licensed in April 2003 the use of leak-before-break (LBB) methodology in the Krsko NPP for the primary loop including surge line and connecting pipelines with minimal diameter of 6 inch. The SNSA decision based also on fracture mechanics analyses that include direct pipe failure mechanisms such as water hammer, creep damage, erosion and corrosion, fatigue and environmental conditions over the entire life of the plant. The evaluation of the operating transients pointed out, that presumed loadings, used for the LBB analysis, did not incorporate all the fast thermal transients data. For that purpose the SNSA requested Faculty of Mechanical Engineering (FS) in Ljubljana to perform additional analyses. The results of the analysis shall confirm the validity of the LBB analysis. (author)

  13. Towards traceable transient pressure metrology

    Science.gov (United States)

    Hanson, Edward; Olson, Douglas A.; Liu, Haijun; Ahmed, Zeeshan; Douglass, Kevin O.

    2018-04-01

    We describe our progress in developing the infrastructure for traceable transient measurements of pressure. Towards that end, we have built and characterized a dual diaphragm shock tube that allows us to achieve shock amplitude reproducibility of approximately 2.3% for shocks with Mach speeds ranging from 1.26–1.5. In this proof-of-concept study we use our shock tube to characterize the dynamic response of photonic sensors embedded in polydimethylsiloxane (PDMS), a material of choice for soft tissue phantoms. Our results indicate that the PDMS-embedded photonic sensors response to shock evolves over a tens to hundreds of microseconds time scale making it a useful system for studying transient pressures in soft tissue.

  14. Forward and inverse modeling of near-well flow using discrete edge-based vector potentials

    NARCIS (Netherlands)

    Zijl, W.

    2007-01-01

    Homogeneous effective permeabilities in the near-well region are generally obtained using analytical solutions for transient flow. In contrast, this paper focuses on heterogeneous permeability obtained from steady flow solutions, although extensions to unsteady flow are introduced too. Exterior

  15. Steady-state and transient heat transfer through fins of complex geometry

    Directory of Open Access Journals (Sweden)

    Taler Dawid

    2014-06-01

    Full Text Available Various methods for steady-state and transient analysis of temperature distribution and efficiency of continuous-plate fins are presented. For a constant heat transfer coefficient over the fin surface, the plate fin can be divided into imaginary rectangular or hexangular fins. At first approximate methods for determining the steady-state fin efficiency like the method of equivalent circular fin and the sector method are discussed. When the fin geometry is complex, thus transient temperature distribution and fin efficiency can be determined using numerical methods. A numerical method for transient analysis of fins with complex geometry is developed. Transient temperature distributions in continuous fins attached to oval tubes is computed using the finite volume - finite element methods. The developed method can be used in the transient analysis of compact heat exchangers to calculate correctly the heat flow rate transferred from the finned tubes to the fluid.

  16. Transient Stability Improvement of IEEE 9 Bus System Using Power World Simulator

    Directory of Open Access Journals (Sweden)

    Kaur Ramandeep

    2016-01-01

    Full Text Available The improvement of transient stability of power system was one of the most challenging research areas in power engineer.The main aim of this paper was transient stability analysis and improvement of IEEE 9 bus system. These studies were computed using POWER WORLD SIMULATOR. The IEEE 9 bus system was modelled in power world simulator and load flow studies were performed to determine pre-fault conditions in the system using Newton-Raphson method. The transient stability analysis was carried out using Runga method during three-phase balanced fault. For the improvement transient stability, the general methods adopted were fast acting exciters, FACT devices and addition of parallel transmission line. These techniques play an important role in improving the transient stability, increasing transmission capacity and damping low frequency oscillations.

  17. Transient pseudohypoparathyroidism and neonatal seizure.

    Science.gov (United States)

    Manzar, S

    2001-04-01

    The case of a neonate is presented who had late onset seizure associated with hypocalcemia, hyperphosphatemia, and raised parathyroid hormone. The infant did not have any stigmata of pseudohypoparathyroidism. The hypocalcemia was initially resistant to calcium therapy, but responded to vitamin D analog therapy. The diagnosis of 'transient neonatal pseudohypoparathyroidism' was entertained, as the infant remained stable and seizure-free with normal serum biochemistry during 8 months of follow-up.

  18. Transient cognitive changes after craniotomy.

    Science.gov (United States)

    Hannegan, L

    1989-06-01

    Little has been written on the subject of cognitive and behavioral changes that may follow craniotomy. Neuroscience nurses who care for craniotomy patients often see transient alterations in behavior, intellect and personality similar to those occurring after minor head injury or subarachnoid hemorrhage. These changes may lead to depression and alter family dynamics. Interventional strategies, including cognitive screening, family counseling and thorough discharge planning are essential for helping patients and family members anticipate potential deficits and cope with life after craniotomy.

  19. Integrated, digital experiment transient control and safety protection of an in-pile test

    International Nuclear Information System (INIS)

    Thomas, R.W.; Whitacre, R.F.; Klingler, W.B.

    1982-01-01

    The Sodium Loop Safety Facility experimental program has demonstrated that in-pile loop fuel failure transient tests can be digitally controlled and protected with reliability and precision. This was done in four nuclear experiments conducted in the Engineering Test Reactor operated by EG and G Idaho, Inc., at the Idaho National Engineering Laboratory. Loop sodium flow and reactor power transients can be programmed to sponsor requirements and verified prior to the test. Each controller has redundancy, which reduces the effect of single failures occurring during test transients. Feedback and reject criteria are included in the reactor power control. Timed sequencing integrates the initiation of the controllers, programmed safety set-points, and other experiment actions (e.g., planned scram). Off-line and on-line testing is included. Loss-of-flow, loss-of-piping-integrity, boiling-window, transient-overpower, and local fault tests have been successfully run using this system

  20. Pressure transients resulting from sodium-water reaction following a large leak in LMFBR steam generator

    International Nuclear Information System (INIS)

    Rajput, A.K.

    1984-01-01

    The study of sodium water reaction, following a large leak, concerns primarily with the estimation of pressure/flow transients that are developed in the steam generator and the associated secondary circuit. This paper describes the mathematical formulations used in SWRT (Sodium Water Reaction Transients) code developed to estimate such pressure transients for FBTR plant. The results, obtained using SWRT have been presented for a leak in economiser (20m from bottom water header) and for a leak in super heater portions. A time lag of 50 m sec was considered for rupture disc takes to burst once the pressure experienced by it exceeds the set value. Also described in annexure to this paper is the mathematical formulation for two phase transient flow for the better estimation of leak rate from the ruptured end of the damaged heat transfer tube. This leak model considers slip but assumes thermal equilibrium between the liquid and vapour phases

  1. Numerical Simulation of the Transient Process of Power Failure in a Mixed Pump

    Directory of Open Access Journals (Sweden)

    Xudan Ma

    2013-01-01

    Full Text Available A hydraulic-force coupling method was used to simulate the transient process of power failure condition. Computational fluid dynamics (CFD was used to study the three-dimensional (3D, unsteady, incompressible viscous flows in a mixed flow pump in power failure accident. The dynamic mesh (DM method with nonconformal grid boundaries was applied to simulate the variation of rotational speed of the field around the impeller. User-defined function (UDF was used to obtain the rotational speed by solving the momentum conservation equation. External characteristics, such as rotational speed, head, flow rate, and hydraulic torque, were obtained during the transient process. Numerical speed and flow rate were compared with results calculated by semiempirical equation and they were in good agreement. The differences between transient and quasisteady results were also studied. Transient head and quasisteady head did not differ too much. The reason that caused this deviation was theoretically analyzed. The difference was explained to be caused by the inertia effect of the fluid contained in the pump and the pipeline. Internal flow field was also shown. Relative velocity vectors showed that the stall form and existence time in transient simulation were different from those in the quasisteady simulation. It is suspected to be one reason for head deviation.

  2. Cortical computations via transient attractors.

    Directory of Open Access Journals (Sweden)

    Oliver L C Rourke

    Full Text Available The ability of sensory networks to transiently store information on the scale of seconds can confer many advantages in processing time-varying stimuli. How a network could store information on such intermediate time scales, between typical neurophysiological time scales and those of long-term memory, is typically attributed to persistent neural activity. An alternative mechanism which might allow for such information storage is through temporary modifications to the neural connectivity which decay on the same second-long time scale as the underlying memories. Earlier work that has explored this method has done so by emphasizing one attractor from a limited, pre-defined set. Here, we describe an alternative, a Transient Attractor network, which can learn any pattern presented to it, store several simultaneously, and robustly recall them on demand using targeted probes in a manner reminiscent of Hopfield networks. We hypothesize that such functionality could be usefully embedded within sensory cortex, and allow for a flexibly-gated short-term memory, as well as conferring the ability of the network to perform automatic de-noising, and separation of input signals into distinct perceptual objects. We demonstrate that the stored information can be refreshed to extend storage time, is not sensitive to noise in the system, and can be turned on or off by simple neuromodulation. The diverse capabilities of transient attractors, as well as their resemblance to many features observed in sensory cortex, suggest the possibility that their actions might underlie neural processing in many sensory areas.

  3. A transient absorption study of allophycocyanin

    Indian Academy of Sciences (India)

    Transient dynamics of allophycocyanin trimers and monomers are observed by using the pump-probe, transient absorption technique. The origin of spectral components of the transient absorption spectra is discussed in terms of both kinetics and spectroscopy. We find that the energy gap between the ground and excited ...

  4. Prandtl number variation on transient forced convection flow in a ...

    African Journals Online (AJOL)

    user

    and average Nusselt number, mean temperature of the fluids (base fluid and nanofluid) and subdomain velocity with the variation of non-dimensional time (τ) ... where the effects of non-uniform particle diameter and temperature on thermal conductivity were shown. Up to now, all the .... is dynamic viscosity and. (. ) (. ) 2. 2. 2.

  5. A new transiently chaotic flow with ellipsoid equilibria

    Indian Academy of Sciences (India)

    Biomedical Engineering Department, Amirkabir University of Technology, Tehran 15875-4413, Iran; School of Electronics and Telecommunications, Hanoi University of Science and Technology, 01 Dai Co Viet, Hanoi, Vietnam; Physics Department, Aristotle University of Thessaloniki, 54124 Thessaloníki, Greece; Center for ...

  6. A new transiently chaotic flow with ellipsoid equilibria

    Indian Academy of Sciences (India)

    SHIRIN PANAHI

    2018-02-08

    5. 1Biomedical Engineering Department, Amirkabir University of Technology, Tehran 15875-4413, Iran. 2School of Electronics and Telecommunications, Hanoi University of Science and Technology, 01 Dai Co Viet,. Hanoi ...

  7. Transient multiphase flow modeling of gas well liquid loading

    NARCIS (Netherlands)

    Veeken, K.; Hu, B.; Schiferli, W.

    2009-01-01

    Gas well liquid loading occurs when gas production becomes insufficient to lift the associated liquids to surface. When that happens gas production first turns intermittent and eventually stops. Hence in depleting gas reservoirs the technical abandonment pressure and ultimate recovery are typically

  8. Prandtl number variation on transient forced convection flow in a ...

    African Journals Online (AJOL)

    user

    distribution of nanoparticles and uncertainties in the thermophysical properties of nanofluids. Most of ..... Grid Refinement Test. In order to determine the proper grid size for this study, a grid independence test is conducted with five types of mesh for Pr = 1.47, Re = 100 and φ = 5%. ..... concept, Int. J. Heat Mass Transfer, Vol.

  9. Steam generator transient studies using a simplified two-fluid computer code

    International Nuclear Information System (INIS)

    Munshi, P.; Bhatnagar, R.; Ram, K.S.

    1985-01-01

    A simplified two-fluid computer code has been used to simulate reactor-side (or primary-side) transients in a PWR steam generator. The disturbances are modelled as ramp inputs for pressure, internal energy and mass flow-rate for the primary fluid. The CPU time for a transient duration of 4 s is approx. 10 min on a DEC-1090 computer system. The results are thermodynamically consistent and encouraging for further studies. (author)

  10. Transient Natural Convection in Porous Square Cavity Heated and Cooled on Adjacent Walls

    OpenAIRE

    M. S. Selamat; I. Hashim; M. K. Hasan

    2012-01-01

    Transient natural convection in a square cavity filled with a porous medium is studied numerically. The cavity is assumed heated from one vertical wall and cooled at the top, while the other walls are kept adiabatic. The governing equations are solved numerically by a finite difference method. The effects of Rayleigh number on the initial transient state up to the steady state are investigated for Rayleigh number ranging from 10 to 2×102. The evolutions of flow patterns and temperature distri...

  11. Development of a computer code for Dalat research reactor transient analysis

    International Nuclear Information System (INIS)

    Le Vinh Vinh; Nguyen Thai Sinh; Huynh Ton Nghiem; Luong Ba Vien; Pham Van Lam; Nguyen Kien Cuong

    2003-01-01

    DRSIM (Dalat Reactor SIMulation) computer code has been developed for Dalat reactor transient analysis. It is basically a coupled neutronics-hydrodynamics-heat transfer code employing point kinetics, one dimensional hydrodynamics and one dimensional heat transfer. The work was financed by VAEC and DNRI in the framework of institutional R and D programme. Some transient problems related to reactivity and loss of coolant flow was carried out by DRSIM using temperature and void coefficients calculated by WIMS and HEXNOD2D codes. (author)

  12. Transient Wave Scattering and Its Influence on Transient Analysis and Leak Detection in Urban Water Supply Systems: Theoretical Analysis and Numerical Validation

    Directory of Open Access Journals (Sweden)

    Huan-Feng Duan

    2017-10-01

    Full Text Available This paper investigates the impacts of non-uniformities of pipe diameter (i.e., an inhomogeneous cross-sectional area along pipelines on transient wave behavior and propagation in water supply pipelines. The multi-scale wave perturbation method is firstly used to derive analytical solutions for the amplitude evolution of transient pressure wave propagation in pipelines, considering regular and random variations of cross-sectional area, respectively. The analytical analysis is based on the one-dimensional (1D transient wave equation for pipe flow. Both derived results show that transient waves can be attenuated and scattered significantly along the longitudinal direction of the pipeline due to the regular and random non-uniformities of pipe diameter. The obtained analytical results are then validated by extensive 1D numerical simulations under different incident wave and non-uniform pipe conditions. The comparative results indicate that the derived analytical solutions are applicable and useful to describe the wave scattering effect in complex pipeline systems. Finally, the practical implications and influence of wave scattering effects on transient flow analysis and transient-based leak detection in urban water supply systems are discussed in the paper.

  13. RETRAN operational transient analysis of the Big Rock Point plant boiling water reactor

    International Nuclear Information System (INIS)

    Sawtelle, G.R.; Atchison, J.D.; Farman, R.F.; VandeWalle, D.J.; Bazydlo, H.G.

    1983-01-01

    Energy Incorporated used the RETRAN computer code to model and calculate nine Consumers Power Company Big Rock Point Nuclear Power Plant transients. RETRAN, a best-estimate, one-dimensional, homogeneous-flow thermal-equilibrium code, is applicable to FSAR Chapter 15 transients for Conditions 1 through IV. The BWR analyses were performed in accordance with USNRC Standard Review Plan criteria and in response to the USNRC Systematic Evaluation Program. The RETRAN Big Rock Point model was verified by comparison to plant startup test data. This paper discusses the unique modeling techniques used in RETRAN to model this steam-drum-type BWR. Transient analyses results are also presented

  14. Sodium boiling and mixed oxide fuel thermal behavior in FBR undercooling transients; W-1 SLSF experiment results

    International Nuclear Information System (INIS)

    Henderson, J.M.; Wood, S.A.; Knight, D.D.

    1981-01-01

    The W-1 Sodium Loop Safety Facility (SLSF) Experiment was conducted to study fuel pin heat release characteristics during a series of LMFBR Loss-of-Piping Integrity (LOPI) transients and to investigate a regime of coolant boiling during a second series of transients at low, medium and high bundle power levels. The LOPI transients produced no coolant boiling and showed only small changes in coolant temperatures as the test fuel microstructure changed from a fresh, unrestructured to a low burnup, restructured condition. During the last of seven boiling transients, intense coolant boiling produced inlet flow reversal, cladding dryout and moderate cladding melting

  15. OPR1000 RCP Flow Coastdown Analysis using SPACE Code

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Hyuk; Kim, Seyun [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The Korean nuclear industry developed a thermal-hydraulic analysis code for the safety analysis of PWRs, named SPACE(Safety and Performance Analysis Code for Nuclear Power Plant). Current loss of flow transient analysis of OPR1000 uses COAST code to calculate transient RCS(Reactor Coolant System) flow. The COAST code calculates RCS loop flow using pump performance curves and RCP(Reactor Coolant Pump) inertia. In this paper, SPACE code is used to reproduce RCS flowrates calculated by COAST code. The loss of flow transient is transient initiated by reduction of forced reactor coolant circulation. Typical loss of flow transients are complete loss of flow(CLOF) and locked rotor(LR). OPR1000 RCP flow coastdown analysis was performed using SPACE using simplified nodalization. Complete loss of flow(4 RCP trip) was analyzed. The results show good agreement with those from COAST code, which is CE code for calculating RCS flow during loss of flow transients. Through this study, we confirmed that SPACE code can be used instead of COAST code for RCP flow coastdown analysis.

  16. Transient Splitting of Conoscopic Isogyres of a Uniaxial Nematic

    Science.gov (United States)

    Kim, Young-Ki; Senuk, Bohdan; Tortora, Luana; Sprunt, Samuel; Lehmann, Matthias; Lavrentovich, Oleg D.

    2012-02-01

    The phase identification is often based on conoscopic observations of homeotropic cells: A uniaxial nematic produces a pattern with crossed isogyres, while the biaxial nematic shows a split of isogyres. We demonstrate that the splitting of isogyres occurs even when the material remains in the uniaxial nematic phase. In particular, in the bent core material J35, splitting of isogyres is caused by change of the temperature. The effect is transient and the isogyres return to a uniaxial (crossed) configuration after a certain time that depends on sample thickness, temperature, and rate of temperature change; the time varies from a few seconds to tens of hours. The transient splitting is caused by the temperature-induced material flow that triggers a (uniaxial) director tilt in the cell. The flows and the director tilt are demonstrated by the CARS microscopy and fluorescent confocal polarizing microscopy (FCPM). This transient effect is general and can be observed even in E7 and 5CB. The effect should be considered in textural identifications of potential biaxial nematic materials.

  17. Audiovisual integration of stimulus transients

    DEFF Research Database (Denmark)

    Andersen, Tobias; Mamassian, Pascal

    2008-01-01

    A change in sound intensity can facilitate luminance change detection. We found that this effect did not depend on whether sound intensity and luminance increased or decreased. In contrast, luminance identification was strongly influenced by the congruence of luminance and sound intensity change...... leaving only unsigned stimulus transients as the basis for audiovisual integration. Facilitation of luminance detection occurred even with varying audiovisual stimulus onset asynchrony and even when the sound lagged behind the luminance change by 75 ms supporting the interpretation that perceptual...... integration rather than a reduction of temporal uncertainty or effects of attention caused the effect....

  18. Transient internal characteristic study of a centrifugal pump during startup process

    International Nuclear Information System (INIS)

    Hu, F F; Ma, X D; Wu, D Z; Wang, L Q

    2012-01-01

    The transient process of a centrifugal pump existed in a variety of occasions. There were a lot of researches in the external characteristic in startup process and stopping process, but internal characteristics were less observed and studied. Study of the internal flow field had significant meanings. The performance of a pump could be evaluated and improved by revealing the flow field. In the other hand, the prediction of external characteristic was based on the correct analysis of the internal flow. In this paper, theoretical method and numerical simulation were used to study the internal characteristic of a centrifugal pump. The theoretical study showed that the relative flow in an impeller was composed of homogeneous flow and axial vortex flow. The vortex intensity was mainly determined by angular velocity of impeller, flow channel width and blade curvature. In order to get the internal flow field and observe the evolution of transient internal flow in the impeller, Computational Fluid Dynamics(CFD) were used to study the three-dimensional unsteady incompressible viscous flows in a centrifugal pump during starting period. The Dynamic Mesh (DM) method with non-conformal grid boundaries was applied to get the external characteristic and internal flow field. The simulate model included three pumps with different blade numbers and the same blade curvature. The relative velocity vector showed that there was a big axial vortex in impeller channel. At the beginning, the vortex was raised in the pressure side of the impeller outlet and with time went on, it shifted to the middle flow channel of the impeller and the vortex intensity increased. When the speed and flow rate reached a definite value, the influence of the axial vortex began to get smaller. The vortex developed faster when the flow channel got narrower. Due to the evolution of axial vortex, the slip factor during starting period was smaller than that in quasi-steady condition. As a result, transient head was

  19. System transient response to loss of off-site power

    International Nuclear Information System (INIS)

    Sozer, A.

    1990-01-01

    A simultaneous trip of the reactor, main circulation pumps, secondary coolant pumps, and pressurizer pump due to loss of off-site power at the High Flux Isotope Reactor (HFIR) located at the Oak Ridge National Laboratory (ORNL) has been analyzed to estimate available safety margin. A computer model based on the Modular Modeling System code has been used to calculate the transient response of the system. The reactor depressurizes from 482.7 psia down to about 23 psia in about 50 seconds and remains stable thereafter. Available safety margin has been estimated in terms of the incipient boiling heat flux ratio. It is a conservative estimate due to assumed less than available primary and secondary flows and higher than normal depressurization rate. The ratio indicates no incipient boiling conditions at the hot spot. No potential damage to the fuel is likely to occur during this transient. 2 refs., 6 figs

  20. Transient analysis of space reactors

    International Nuclear Information System (INIS)

    Giap, H.Q.; Best, F.

    1985-01-01

    Nuclear reactors are being considered as the primary energy source for an increasing number of space missions including the National Aeronautics and Space Administration's space station and the Strategic Defense Initiative's SP-100. Conceptual reactor designs include fast and thermal spectrum reactors with liquid-metal or gas cooling delivering thermal energy to Brayton, Stirling, thermoelectric, thermoionic, or Rankine cycle power conversion systems. Almost all designs utilize a thermal radiator for waste heat rejection, although the radiator may assume such exotic forms as fans of liquid-metal droplets or metal filaments floating in free space. The reactor, power conversion, and heat rejection systems must operate in zero gravity, be uniformly small and lightweight, and utilize exotic materials compared with terrestrial technology. Therefore, the problems of system design and analysis are unique to space applications, and new analysis tools must be developed. With this motivation, the Transient Analysis of Space Reactors (TASR) computer code has been developed to predict system performance under steady-state and transient conditions. The SP-100 space reactor system, being designed by General Electric (GE) Company, was used as the test system for the TASR code. At full power, the SP-100 produces 110 kW(e) from 2.21 MW(t) via a thermoelectric conversion system

  1. PRISMATIC CORE COUPLED TRANSIENT BENCHMARK

    Energy Technology Data Exchange (ETDEWEB)

    J. Ortensi; M.A. Pope; G. Strydom; R.S. Sen; M.D. DeHart; H.D. Gougar; C. Ellis; A. Baxter; V. Seker; T.J. Downar; K. Vierow; K. Ivanov

    2011-06-01

    The Prismatic Modular Reactor (PMR) is one of the High Temperature Reactor (HTR) design concepts that have existed for some time. Several prismatic units have operated in the world (DRAGON, Fort St. Vrain, Peach Bottom) and one unit is still in operation (HTTR). The deterministic neutronics and thermal-fluids transient analysis tools and methods currently available for the design and analysis of PMRs have lagged behind the state of the art compared to LWR reactor technologies. This has motivated the development of more accurate and efficient tools for the design and safety evaluations of the PMR. In addition to the work invested in new methods, it is essential to develop appropriate benchmarks to verify and validate the new methods in computer codes. The purpose of this benchmark is to establish a well-defined problem, based on a common given set of data, to compare methods and tools in core simulation and thermal hydraulics analysis with a specific focus on transient events. The benchmark-working group is currently seeking OECD/NEA sponsorship. This benchmark is being pursued and is heavily based on the success of the PBMR-400 exercise.

  2. Extreme Transients in the High Energy Universe

    Science.gov (United States)

    Kouveliotou, Chryssa

    2013-01-01

    The High Energy Universe is rich in diverse populations of objects spanning the entire cosmological (time)scale, from our own present-day Milky Way to the re-ionization epoch. Several of these are associated with extreme conditions irreproducible in laboratories on Earth. Their study thus sheds light on the behavior of matter under extreme conditions, such as super-strong magnetic fields (in excess of 10^14 G), high gravitational potentials (e.g., Super Massive Black Holes), very energetic collimated explosions resulting in relativistic jet flows (e.g., Gamma Ray Bursts, exceeding 10^53 ergs). In the last thirty years, my work has been mostly focused on two apparently different but potentially linked populations of such transients: magnetars (highly magnetized neutron stars) and Gamma Ray Bursts (strongly beamed emission from relativistic jets), two populations that constitute unique astrophysical laboratories, while also giving us the tools to probe matter conditions in the Universe to redshifts beyond z=10, when the first stars and galaxies were assembled. I did not make this journey alone I have either led or participated in several international collaborations studying these phenomena in multi-wavelength observations; solitary perfection is not sufficient anymore in the world of High Energy Astrophysics. I will describe this journey, present crucial observational breakthroughs, discuss key results and muse on the future of this field.

  3. Engineered Promoters for Potent Transient Overexpression.

    Directory of Open Access Journals (Sweden)

    Dan Y Even

    Full Text Available The core promoter, which is generally defined as the region to which RNA Polymerase II is recruited to initiate transcription, plays a pivotal role in the regulation of gene expression. The core promoter consists of different combinations of several short DNA sequences, termed core promoter elements or motifs, which confer specific functional properties to each promoter. Earlier studies that examined the ability to modulate gene expression levels via the core promoter, led to the design of strong synthetic core promoters, which combine different core elements into a single core promoter. Here, we designed a new core promoter, termed super core promoter 3 (SCP3, which combines four core promoter elements (the TATA box, Inr, MTE and DPE into a single promoter that drives prolonged and potent gene expression. We analyzed the effect of core promoter architecture on the temporal dynamics of reporter gene expression by engineering EGFP expression vectors that are driven by distinct core promoters. We used live cell imaging and flow cytometric analyses in different human cell lines to demonstrate that SCPs, particularly the novel SCP3, drive unusually strong long-term EGFP expression. Importantly, this is the first demonstration of long-term expression in transiently transfected mammalian cells, indicating that engineered core promoters can provide a novel non-viral strategy for biotechnological as well as gene-therapy-related applications that require potent expression for extended time periods.

  4. A COMETHE version with transient capability

    International Nuclear Information System (INIS)

    Vliet, J. van; Lebon, G.; Mathieu, P.

    1980-01-01

    A version of the COMETHE code is under development to simulate transient situations. This paper focuses on some aspects of the transient heat transfer models. Initially the coupling between transient heat transfer and other thermomechanical models is discussed. An estimation of the thermal characteristic times shows that the cladding temperatures are often in quasi-steady state. In order to reduce the computing time, calculations are therefore switched from a transient to a quasi-static numerical procedure as soon as such a quasi-equilibrium is detected. The temperature calculation is performed by use of the Lebon-Lambermont restricted variational principle, with piecewise polynoms as trial functions. The method has been checked by comparison with some exact results and yields good agreement for transient as well as for quasi-static situations. This method therefore provides a valuable tool for the simulation of the transient behaviour of nuclear reactor fuel rods. (orig.)

  5. Investigating anomalous transport of electrolytes in charged porous media

    Science.gov (United States)

    Skjøde Bolet, Asger Johannes; Mathiesen, Joachim

    2017-04-01

    Surface charge is know to play an important role in microfluidics devices when dealing with electrolytes and their transport properties. Similarly, surface charge could play a role for transport in porous rock with submicron pore sizes. Estimates of the streaming potentials and electro osmotic are mostly considered in simple geometries both using analytic and numerical tools, however it is unclear at present how realistic complex geometries will modify the dynamics. Our work have focused on doing numerical studies of the full three-dimensional Stokes-Poisson-Nernst-Planck problem for electrolyte transport in porous rock. As the numerical implementation, we have used a finite element solver made using the FEniCS project code base, which can both solve for a steady state configuration and the full transient. In the presentation, we will show our results on anomalous transport due to electro kinetic effects such as the streaming potential or the electro osmotic effect.

  6. Transient analysis of mercury experimental loop using the RELAP5 code. 3rd report. Transient analysis using mercury properties

    International Nuclear Information System (INIS)

    Kinoshita, Hidetaka; Kaminaga, Masanori; Hino, Ryutaro

    2000-02-01

    In order to promote the Neutron Science Project of JAERI, the design of a 5MW-spallation target system is in progress with the purpose of producing a practical neutron application while at the same time adhering to the highest levels of safety. To establish the safety of the target system, it is important to understand the transient behaviors during anticipated operational events of the system, and to design the safety protection systems for the safe termination of the transients. This report presents the analytical results of transient behaviors in the mercury experimental loop using mercury properties. At first, the analytical pressure distributions were compared with experimental data measured with the mercury experimental loop. The modeling data were modified to reproduce the actual pressure distributions of the mercury experimental loop. Then a loss of forced convection and a loss of coolant accident were analyzed. In the case of the pump trip, the transient analysis was conducted using two types of mercury pumps, the mechanical type pump with moment of inertia, and the electrical-magnetic type pump without moment of inertia. The results show there was no clear difference in the two analyses, since the mercury had a large inertia, which was 13.5 times that of the water. Moreover, in the case of a pipe rupture at the pump exit, a moderate pressure decrease was confirmed when a small breakage area existed in which the coolant flowed out gradually. Based on these results, it was appeared that the transient fluctuation of pressure in the mercury loop would not become large and accidents would have to be detected by small fluctuations in pressure. Based on these analyses, we plan to conduct a simulation test to verify the RELAP5 code, and then the analysis of a full-scale mercury system will be performed. (author)

  7. Nonlinear flow model for well production in an underground formation

    Directory of Open Access Journals (Sweden)

    J. C. Guo

    2013-05-01

    Full Text Available Fluid flow in underground formations is a nonlinear process. In this article we modelled the nonlinear transient flow behaviour of well production in an underground formation. Based on Darcy's law and material balance equations, we used quadratic pressure gradients to deduce diffusion equations and discuss the origins of nonlinear flow issues. By introducing an effective-well-radius approach that considers skin factor, we established a nonlinear flow model for both gas and liquid (oil or water. The liquid flow model was solved using a semi-analytical method, while the gas flow model was solved using numerical simulations because the diffusion equation of gas flow is a stealth function of pressure. For liquid flow, a series of standard log-log type curves of pressure transients were plotted and nonlinear transient flow characteristics were analyzed. Qualitative and quantitative analyses were used to compare the solutions of the linear and nonlinear models. The effect of nonlinearity upon pressure transients should not be ignored. For gas flow, pressure transients were simulated and compared with oil flow under the same formation and well conditions, resulting in the conclusion that, under the same volume rate production, oil wells demand larger pressure drops than gas wells. Comparisons between theoretical data and field data show that nonlinear models will describe fluid flow in underground formations realistically and accurately.

  8. Instrument response during overpower transients at TREAT

    International Nuclear Information System (INIS)

    Meek, C.C.; Bauer, T.H.; Hill, D.J.; Froehle, P.H.; Klickman, A.E.; Tylka, J.P.; Doerner, R.C.; Wright, A.E.

    1982-01-01

    A program to empirically analyze data residuals or noise to determine instrument response that occurs during in-pile transient tests is out-lined. As an example, thermocouple response in the Mark III loop during a severe overpower transient in TREAT is studied both in frequency space and in real-time. Time intervals studied included both constant power and burst portions of the power transient. Thermocouple time constants were computed. Benefits and limitations of the method are discussed

  9. Custom Type-Curve Generation for Pressure Transient Analysis of Elongated Linear Flow Systems Génération de courbes caractéristiques de réponse en pression pour des systèmes linéaires longs

    Directory of Open Access Journals (Sweden)

    Wagner P. B.

    2006-11-01

    Full Text Available When the drainage area of a flowing well is long and narrow, the pressure transient behavior of the well often cannot be analyzed by conventional means. Well tests which appear to exhibit linear flow behavior for extended periods, beyond the length of time which could be attributed to flow to a fracture, have been observed for both geothermal wells and for oil and gas wells. In geothermal formations and in some of the deep low-permeability gas fields the elongated reservoir shape results from long parallel faults which appear to bound the formations. Typically such wells are also penetrating natural fractures. In other reservoirs the elongated drainage shape is due to the river delta or alluvial environment in which the reservoir sands were originally deposited. Using a recently developed scheme for custom type curve generation for a wide variety of flow geometries, the particular behavior of the well producing from an elongated linear flow system is presented in detail. Cases examined include fractured wells of variable fracture length in varions positions within the flow channel and also of variable length. The effects of partial penetration are also demonstrated. This paper illustrates the use of custom type curves in computer-aided type-curve matching. With the help of relatively inexpensive computer graphics, custom type curves are displayed which exactly represent whatever is known about a particular drainage geometry, including such variables as formation thickness and areal extent, fracture length, partial penetration, and well location. Familles of curves can be generated and displayed along with the data to help determine unknown features of the reservoir geometry. An important contribution included in this work was the development of a set of orthogonal dimensionless parameters which facilitate the generation of familles of type curves which vary one reservoir shape parameter with implied effects on other parameters. The dimensionless

  10. Transient peristaltic transport of grains in a liquid

    Science.gov (United States)

    Marconati, Marco; Rault, Sharvari; Charkhi, Farshad; Burbidge, Adam; Engmann, Jan; Ramaioli, Marco

    2017-06-01

    Pumping suspensions and pastes has always been a significant technological challenge in a number of industrial applications ranging from food processing to mining. Peristaltic pumps have become popular to pump and/or dose complex fluids, due to their robustness. During the transport of suspensions with peristaltic pumps, clogging issues may arise, particularly during transient operations. That is a matter of particular concern whenever the pumping device is used intermittently to generate flow only on demand. Further understanding of the transient dynamics of such systems and of the conditions that can lead to jamming would result in more robust peristaltic pump design. To achieve these goals, an experimental setup that simplifies the statorrotor assembly of a peristaltic hose pump was used. In this setup, a roller transfers momentum to a liquid suspension, upon application of a constant load. The evolution of the velocity of the roller was recorded for different concentrations of mono-dispersed spheres of different diameters. The flow is found not to be strongly dependent on the dispersed particle volume fraction, if the size of the suspended phase is comparable with the hose diameter. Conversely, the flow is strongly slowed down when their size is small and the particle concentration is increased. These findings could help improving the design of peristaltic pumps by a more appropriate sizing, given the diameter of the hose and that of the particles to be transported.

  11. Transient peristaltic transport of grains in a liquid

    Directory of Open Access Journals (Sweden)

    Marconati Marco

    2017-01-01

    Full Text Available Pumping suspensions and pastes has always been a significant technological challenge in a number of industrial applications ranging from food processing to mining. Peristaltic pumps have become popular to pump and/or dose complex fluids, due to their robustness. During the transport of suspensions with peristaltic pumps, clogging issues may arise, particularly during transient operations. That is a matter of particular concern whenever the pumping device is used intermittently to generate flow only on demand. Further understanding of the transient dynamics of such systems and of the conditions that can lead to jamming would result in more robust peristaltic pump design. To achieve these goals, an experimental setup that simplifies the statorrotor assembly of a peristaltic hose pump was used. In this setup, a roller transfers momentum to a liquid suspension, upon application of a constant load. The evolution of the velocity of the roller was recorded for different concentrations of mono-dispersed spheres of different diameters. The flow is found not to be strongly dependent on the dispersed particle volume fraction, if the size of the suspended phase is comparable with the hose diameter. Conversely, the flow is strongly slowed down when their size is small and the particle concentration is increased. These findings could help improving the design of peristaltic pumps by a more appropriate sizing, given the diameter of the hose and that of the particles to be transported.

  12. OPTICAL TRANSIENT DETECTOR (OTD) LIGHTNING V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Optical Transient Detector (OTD) records optical measurements of global lightning events in the daytime and nighttime. The data includes individual point...

  13. Electromagnetic Transients in Power Cables

    DEFF Research Database (Denmark)

    Silva, Filipe Faria Da; Bak, Claus Leth

    for this information in Ph.D. theses and scientific papers. To finish the chapter, we study short-circuits in cables, which can be rather different from short-circuit in OHLs, because of the current returning in the screen. The screen can also be bonded on different configurations, influencing both the magnitude...... of the short-circuit current and of the transient recovery voltage. Chapter 5, ‘‘System Modelling and Harmonics’’, starts by proposing a method that can be used when deciding how much of the network to model when doing a simulation of an energisation/restrike together with the possible limitations...... demonstrates how analytical analysis of simple systems can be made. These principles will be used in later chapters in the study of more complex scenarios. Chapter 3, ‘‘Travelling Waves and Modal Domain’’, reviews the Telegraph equations and how to calculate the loop and series impedance matrices as well...

  14. Transient ischemic attack: diagnostic evaluation.

    Science.gov (United States)

    Messé, Steven R; Jauch, Edward C

    2008-08-01

    A transient ischemic attack portends significant risk of a stroke. Consequently, the diagnostic evaluation in the emergency department is focused on identifying high-risk causes so that preventive strategies can be implemented. The evaluation consists of a facilitated evaluation of the patient's metabolic, cardiac, and neurovascular systems. At a minimum, the following tests are recommended: fingerstick glucose level, electrolyte levels, CBC count, urinalysis, and coagulation studies; noncontrast computed tomography (CT) of the head; electrocardiography; and continuous telemetry monitoring. Vascular imaging studies, such as carotid ultrasonography, CT angiography, or magnetic resonance angiography, should be performed on an urgent basis and prioritized according to the patient's risk stratification for disease. Consideration should be given for echocardiography if no large vessel abnormality is identified.

  15. Transient photoconductivity in amorphous semiconductors

    International Nuclear Information System (INIS)

    Mpawenayo, P.

    1997-07-01

    Localized states in amorphous semiconductors are divided in disorder induced shallow trap levels and dangling bonds deep states. Dangling bonds are assumed here to be either neutral or charged and their energy distribution is a single gaussian. Here, it is shown analytically that transient photocurrent in amorphous semiconductors is fully controlled by charge carriers transitions between localized states for one part and tunneling hopping carriers on the other. Localized dangling bonds deep states act as non radiative recombination centres, while hopping tunnelling is assisted by the Coulomb interaction between defects sites. The half-width of defects distribution is the disorder parameter that determines the carrier hopping time between defects sites. The macroscopic time that explains the long decay response times observed will all types of amorphous semiconductors is duly thought to be temperature dependent. Basic equations developed by Longeaud and Kleider are solved for the general case of a semiconductor after photo-generation. It turns out that the transient photoconductivity decay has two components; one with short response times from carriers trap-release transitions between shallow levels and extended states and a hopping component made of inter-dependent exponentials whose time constants span in larger ranges depending on disorder. The photoconductivity hopping component appears as an additional term to be added to photocurrents derived from existing models. The results of the present study explain and complete the power law decay derived in the multiple trapping models developed 20 years ago only in the approximation of the short response time regime. The long response time regime is described by the hopping macroscopic time. The present model is verified for all samples of amorphous semiconductors known so far. Finally, it is proposed to improved the modulated photoconductivity calculation techniques by including the long-lasting hopping dark documents

  16. Stochastic parametric resonance in shear flows

    Directory of Open Access Journals (Sweden)

    F. J. Poulin

    2005-01-01

    Full Text Available Time-periodic shear flows can give rise to Parametric Instability (PI, as in the case of the Mathieu equation (Stoker, 1950; Nayfeh and Mook, 1995. This mechanism results from a resonance between the oscillatory basic state and waves that are superimposed on it. Farrell and Ioannou (1996a, b explain that PI occurs because the snap-shots of the velocity profile are subject to transient growth. If the flows were purely steady the transient growth would subside and not have any long lasting effect. However, the coupling between transient growth and the time variation of the basic state create PI. Mathematically, transient growth, and therefore PI, are due to the nonorthogonal eigenspace in the linearized system. Poulin et al. (2003 studied a time-periodic barotropic shear flow that exhibited PI, and thereby produced mixing at the interface between Potential Vorticity (PV fronts. The instability led to the formation of vortices that were stretched. A later study of an oscillatory current in the Cape Cod Bay illustrated that PI can occur in realistic shear flows (Poulin and Flierl, 2005. These studies assumed that the basic state was periodic with a constant frequency and amplitude. In this work we study a shear flow similar to that found in Poulin et al. (2003, but now where the magnitude of vorticity is a stochastic variable. We determine that in the case of stochastic shear flows the transient growth of perturbations of the snapshots of the basic state still generate PI.

  17. Review of Transient Fuel Test Results at Sandia National Laboratories and the Potential for Future Fast Reactor Fuel Transient Testing in the Annular Core Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Steven A.; Pickard, Paul S.; Parma, Edward J.; Vernon, Milton E.; Kelly, John; Tikare, Veena [Sandia National Laboratories, Org 6872 MS-1146, PO Box 5800 Albuquerque, New Mexico 87185 (United States)

    2009-06-15

    Reactor driven transient tests of fast reactor fuels may be required to support the development and certification of new fuels for Fast Reactors. The results of the transient fuel tests will likely be needed to support licensing and to provide validation data to support the safety case for a variety of proposed fast fuel types and reactors. In general reactor driven transient tests are used to identify basic phenomenology during reactor transients and to determine the fuel performance limits and margins to failure during design basis accidents such as loss of flow, loss of heat sink, and reactivity insertion accidents. This paper provides a summary description of the previous Sandia Fuel Disruption and Transient Axial Relocation tests that were performed in the Annular Core Research Reactor (ACRR) for the U.S. Nuclear Regulatory Commission almost 25 years ago. These tests consisted of a number of capsule tests and flowing gas tests that used fission heating to disrupt fresh and irradiated MOX fuel. The behavior of the fuel disruption, the generation of aerosols and the melting and relocation of fuel and cladding was recorded on high speed cinematography. This paper will present videos of the fuel disruption that was observed in these tests which reveal stark differences in fuel behavior between fresh and irradiated fuel. Even though these tests were performed over 25 years ago, their results are still relevant to today's reactor designs. These types of transient tests are again being considered by the Advanced Fuel Cycle Initiative to support the Global Nuclear Energy Partnership because of the need to perform tests on metal fuels and transuranic fuels. Because the Annular Core Research Reactor is the only transient test facility available within the US, a brief summary of Sandia's continued capability to perform these tests in the ACRR will also be provided. (authors)

  18. The Physcomitrella patens System for Transient Gene Expression Assays.

    Science.gov (United States)

    Thévenin, Johanne; Xu, Wenjia; Vaisman, Louise; Lepiniec, Loïc; Dubreucq, Bertrand; Dubos, Christian

    2016-01-01

    Transient expression assays are valuable techniques to study in vivo the transcriptional regulation of gene expression. These methods allow to assess the transcriptional properties of a given transcription factor (TF) or a complex of regulatory proteins against specific DNA motifs, called cis-regulatory elements. Here, we describe a fast, efficient, and reliable method based on the use of Physcomitrella patens protoplasts that allows the study of gene expression in a qualitative and quantitative manner by combining the advantage of GFP (green fluorescent protein) as a marker of promoter activity with flow cytometry for accurate measurement of fluorescence in individual cells.

  19. Torque converter transient characteristics prediction using computational fluid dynamics

    International Nuclear Information System (INIS)

    Yamaguchi, T; Tanaka, K

    2012-01-01

    The objective of this research is to investigate the transient torque converter performance used in an automobile. A new technique in computational fluid dynamics is introduced, which includes the inertia of the turbine in a three dimensional simulation of the torque converter during a launch condition. The simulation results are compared to experimental test data with good agreement across the range of data. In addition, the simulated flow structure inside the torque converter is visualized and compared to results from a steady-state calculation.

  20. Characterization of an induced pressure pumping force for microfluidics

    Science.gov (United States)

    Jiang, Hai; Fan, Na; Peng, Bei; Weng, Xuan

    2017-05-01

    The electro-osmotic pumping and pressure-driven manipulation of fluids are considered as the most common strategies in microfluidic devices. However, both of them exhibit major disadvantages such as hard integration and high reagent consumption, and they are destructive methods for detection and photo bleaching. In this paper, an electric field-effect flow control approach, combining the electro-osmotic pumping force and the pressure-driven pumping force, was developed to generate the induced pressure-driven flow in a T-shaped microfluidic chip. Electro-osmotic flow between the T-intersection and two reservoirs was demonstrated, and it provided a stable, continuous, and electric field-free flow in the section of the microchannel without the electrodes. The velocity of the induced pressure-driven flow was linearly proportional to the applied voltages. Both numerical and experimental investigations were conducted to prove the concept, and the experimental results showed good agreement with the numerical simulations. In comparison to other induced pressure pumping methods, this approach can induce a high and controllable pressure drop in the electric field-free segment, subsequently causing an induced pressure-driven flow for transporting particles or biological cells. In addition, the generation of bubbles and the blocking of the microchannel are avoided.

  1. Characterizing hydraulic fractures in shale gas reservoirs using transient pressure tests

    Directory of Open Access Journals (Sweden)

    Cong Wang

    2015-06-01

    This work presents an unconventional gas reservoir simulator and its application to quantify hydraulic fractures in shale gas reservoirs using transient pressure data. The numerical model incorporates most known physical processes for gas production from unconventional reservoirs, including two-phase flow of liquid and gas, Klinkenberg effect, non-Darcy flow, and nonlinear adsorption. In addition, the model is able to handle various types and scales of fractures or heterogeneity using continuum, discrete or hybrid modeling approaches under different well production conditions of varying rate or pressure. Our modeling studies indicate that the most sensitive parameter of hydraulic fractures to early transient gas flow through extremely low permeability rock is actually the fracture-matrix contacting area, generated by fracturing stimulation. Based on this observation, it is possible to use transient pressure testing data to estimate the area of fractures generated from fracturing operations. We will conduct a series of modeling studies and present a methodology using typical transient pressure responses, simulated by the numerical model, to estimate fracture areas created or to quantity hydraulic fractures with traditional well testing technology. The type curves of pressure transients from this study can be used to quantify hydraulic fractures in field application.

  2. Simulation of the Three Mile Island transient in Semiscale

    International Nuclear Information System (INIS)

    Larson, T.K.; Loomis, G.G.; Shumway, R.W.

    1979-07-01

    This report presents the results of a preliminary review and analysis of the data obtained from eight simulations of the Three Mile Island Unit 2 Nuclear Power Generating Station transient (March 28, 1979) that have been conducted in the Semiscale Mod-3 System. The Semiscale simulations of the Three Mile Island (TMI) transient were basically conducted from the same sequence of events as those recorded in the plant. System initial conditions representative of those in the TMI system were established and the transient was initiated by terminating steam generator feedwater and steam valve flow. The steam generator secondaries were drained to control primary to secondary heat transfer. The pressurizer power operated relief valve, pressurizer code safety valve, and core power trip were operated on system pressure. High pressure safety injection was activated for about one minute during the Semiscale simulations. In addition, both primary loop coolant pumps were shut off in the Semiscale simulation at the same time that the Three Mile Island loop 2A pump was shut off

  3. Transient critical heat flux and blowdown heat-transfer studies

    Energy Technology Data Exchange (ETDEWEB)

    Leung, J.C.

    1980-05-01

    Objective of this study is to give a best-estimate prediction of transient critical heat flux (CHF) during reactor transients and hypothetical accidents. To accomplish this task, a predictional method has been developed. Basically it involves the thermal-hydraulic calculation of the heated core with boundary conditions supplied from experimental measurements. CHF predictions were based on the instantaneous ''local-conditions'' hypothesis, and eight correlations (consisting of round-tube, rod-bundle, and transient correlations) were tested against most recent blowdown heat-transfer test data obtained in major US facilities. The prediction results are summarized in a table in which both CISE and Biasi correlations are found to be capable of predicting the early CHF of approx. 1 s. The Griffith-Zuber correlation is credited for its prediction of the delay CHF that occurs in a more tranquil state with slowly decaying mass velocity. In many instances, the early CHF can be well correlated by the x = 1.0 criterion; this is certainly indicative of an annular-flow dryout-type crisis. The delay CHF occurred at near or above 80% void fraction, and the success of the modified Zuber pool-boiling correlation suggests that this CHF is caused by flooding and pool-boiling type hydrodynamic crisis.

  4. Pressure Transient Model of Water-Hydraulic Pipelines with Cavitation

    Directory of Open Access Journals (Sweden)

    Dan Jiang

    2018-03-01

    Full Text Available Transient pressure investigation of water-hydraulic pipelines is a challenge in the fluid transmission field, since the flow continuity equation and momentum equation are partial differential, and the vaporous cavitation has high dynamics; the frictional force caused by fluid viscosity is especially uncertain. In this study, due to the different transient pressure dynamics in upstream and downstream pipelines, the finite difference method (FDM is adopted to handle pressure transients with and without cavitation, as well as steady friction and frequency-dependent unsteady friction. Different from the traditional method of characteristics (MOC, the FDM is advantageous in terms of the simple and convenient computation. Furthermore, the mechanism of cavitation growth and collapse are captured both upstream and downstream of the water-hydraulic pipeline, i.e., the cavitation start time, the end time, the duration, the maximum volume, and the corresponding time points. By referring to the experimental results of two previous works, the comparative simulation results of two computation methods are verified in experimental water-hydraulic pipelines, which indicates that the finite difference method shows better data consistency than the MOC.

  5. Asiago spectroscopic classification of 3 transients

    Science.gov (United States)

    Tomasella, L.; Benetti, S.; Cappellaro, E.; Turatto, M.

    2018-01-01

    The Asiago Transient Classification Program (Tomasella et al. 2014, AN, 335, 841) reports the spectroscopic classification of AT 2018eq discovered by R. Belligoli (ISSP) in the direction of M31; PS18bq (AT2018bi) discovered by J. Grzegorzek and Pan-STARRS1 in UGC1791; and AT2018C (= Gaia18aak), a blue hostless transient discovered by Gaia.

  6. Plasma transport studies using transient techniques

    International Nuclear Information System (INIS)

    Simonen, T.C.; Brower, D.L.; Efthimion, P.

    1991-01-01

    Selected topics from the Transient Transport sessions of the Transport Task Force Workshop, held February 19-23, 1990, in Hilton Head, South Carolina are summarized. Presentations on sawtooth propagation, ECH modulation, particle modulation, and H-mode transitions are included. The research results presented indicated a growing theoretical understanding and experimental sophistication in the application of transient techniques to transport studies. (Author)

  7. The LOFAR Transients Key Science Project

    NARCIS (Netherlands)

    Stappers, B.; Fender, R.; Wijers, R.

    2009-01-01

    The Transients Key Science Project (TKP) is one of six Key Science Projects of the next generation radio telescope LOFAR. Its aim is the study of transient and variable low-frequency radio sources with an extremely broad science case ranging from relativistic jet sources to pulsars, exoplanets,

  8. Transient characteristics observed in TRACY supercritical experiments

    International Nuclear Information System (INIS)

    Yamane, Yuichi; Nakajima, Ken; Ogawa, Kazuhiko; Aizawa, Eiju; Yanagisawa, Hiroshi; Miyoshi, Yoshinori

    2003-01-01

    A series of supercritical experiments has been performed using the transient experiment criticality facility, TRACY, and some transient characteristics of low-enriched uranyl nitrate solution have been observed. The peak power and the number of fissions have been measured with three types of reactivity insertion method. The data useful for the evaluation of criticality safety for reprocessing plants were obtained. (author)

  9. High energy transients: The millisecond domain

    Indian Academy of Sciences (India)

    A. R. RAO

    2018-02-09

    Feb 9, 2018 ... The search for high energy transients in the millisecond domain has come to the focus in recent ... ulation of transients in the high energy domain with .... The ATLAS col- laboration reported a object called ATLAS17aeu: a fading optical object from the same general direction as GW170104. This object was ...

  10. Flow Rounding

    OpenAIRE

    Kang, Donggu; Payor, James

    2015-01-01

    We consider flow rounding: finding an integral flow from a fractional flow. Costed flow rounding asks that we find an integral flow with no worse cost. Randomized flow rounding requires we randomly find an integral flow such that the expected flow along each edge matches the fractional flow. Both problems are reduced to cycle canceling, for which we develop an $O(m \\log(n^2/m))$ algorithm.

  11. Machine Learning for Zwicky Transient Facility

    Science.gov (United States)

    Mahabal, Ashish; Zwicky Transient Facility, Catalina Real-Time Transient Survey

    2018-01-01

    The Zwicky Transient Facility (ZTF) will operate from 2018 to 2020 covering the accessible sky with its large 47 square degree camera. The transient detection rate is expected to be about a million per night. ZTF is thus a perfect LSST prototype. The big difference is that all of the ZTF transients can be followed up by 4- to 8-m class telescopes. Given the large numbers, using human scanners for separating the genuine transients from artifacts is out of question. For that first step as well as for classifying the transients with minimal follow-up requires machine learning. We describe the tools and plans to take on this task using follow-up facilities, and knowledge gained from archival datasets.

  12. Nuclear reactors transients identification and classification system

    International Nuclear Information System (INIS)

    Bianchi, Paulo Henrique

    2008-01-01

    This work describes the study and test of a system capable to identify and classify transients in thermo-hydraulic systems, using a neural network technique of the self-organizing maps (SOM) type, with the objective of implanting it on the new generations of nuclear reactors. The technique developed in this work consists on the use of multiple networks to do the classification and identification of the transient states, being each network a specialist at one respective transient of the system, that compete with each other using the quantization error, that is a measure given by this type of neural network. This technique showed very promising characteristics that allow the development of new functionalities in future projects. One of these characteristics consists on the potential of each network, besides responding what transient is in course, could give additional information about that transient. (author)

  13. Transient Neurological Symptoms after Spinal Anesthesia

    Directory of Open Access Journals (Sweden)

    Zehra Hatipoglu

    2013-02-01

    Full Text Available Lidocaine has been used for more than 50 years for spinal anesthesia and has a remarkable safety record. In 1993, a new adverse effect, transient neurologic toxicity was described in patients recovering from spinal anesthesia with lidocaine. Transient neurological symptoms have been defined as pain in the lower extremities (buttocks, thighs and legs after an uncomplicated spinal anesthesia and after an initial full recovery during the immediate postoperative period (less than 24 h. The incidence of transient neurological symptoms reported in prospective, randomized trials varies from 4% to 37%. The etiology of transient neurological symptoms remains unkonwn. Despite the transient nature of this syndrome, it has proven to be difficult to treat effectively. Drug or some interventional therapy may be necessary. [Archives Medical Review Journal 2013; 22(1.000: 33-44

  14. Dynamic remedial action scheme using online transient stability analysis

    Science.gov (United States)

    Shrestha, Arun

    Economic pressure and environmental factors have forced the modern power systems to operate closer to their stability limits. However, maintaining transient stability is a fundamental requirement for the operation of interconnected power systems. In North America, power systems are planned and operated to withstand the loss of any single or multiple elements without violating North American Electric Reliability Corporation (NERC) system performance criteria. For a contingency resulting in the loss of multiple elements (Category C), emergency transient stability controls may be necessary to stabilize the power system. Emergency control is designed to sense abnormal conditions and subsequently take pre-determined remedial actions to prevent instability. Commonly known as either Remedial Action Schemes (RAS) or as Special/System Protection Schemes (SPS), these emergency control approaches have been extensively adopted by utilities. RAS are designed to address specific problems, e.g. to increase power transfer, to provide reactive support, to address generator instability, to limit thermal overloads, etc. Possible remedial actions include generator tripping, load shedding, capacitor and reactor switching, static VAR control, etc. Among various RAS types, generation shedding is the most effective and widely used emergency control means for maintaining system stability. In this dissertation, an optimal power flow (OPF)-based generation-shedding RAS is proposed. This scheme uses online transient stability calculation and generator cost function to determine appropriate remedial actions. For transient stability calculation, SIngle Machine Equivalent (SIME) technique is used, which reduces the multimachine power system model to a One-Machine Infinite Bus (OMIB) equivalent and identifies critical machines. Unlike conventional RAS, which are designed using offline simulations, online stability calculations make the proposed RAS dynamic and adapting to any power system

  15. SOIL-AIR PERMEABILITY MEASUREMENT WITH A TRANSIENT PRESSURE BUILDUP METHOD

    Science.gov (United States)

    An analytical solution for transient pressure change in a single venting well was derived from mass conservation of air, Darcy's law of flow in porous media, and the ideal gas law equation of state. Slopes of plots of Pw2 against ln (t+Δt)/Δt similar to Homer's plot were used to ...

  16. Clinical applications of transient elastography

    Directory of Open Access Journals (Sweden)

    Kyu Sik Jung

    2012-06-01

    Full Text Available Chronic liver disease represents a major public health problem, accounting for significant morbidity and mortality worldwide. As prognosis and management depend mainly on the amount and progression of liver fibrosis, accurate quantification of liver fibrosis is essential for therapeutic decision-making and follow-up of chronic liver diseases. Even though liver biopsy is the gold standard for evaluation of liver fibrosis, non-invasive methods that could substitute for invasive procedures have been investigated during past decades. Transient elastography (TE, FibroScan® is a novel non-invasive method for assessment of liver fibrosis with chronic liver disease. TE can be performed in the outpatient clinic with immediate results and excellent reproducibility. Its diagnostic accuracy for assessment of liver fibrosis has been demonstrated in patients with chronic viral hepatitis; as a result, unnecessary liver biopsy could be avoided in some patients. Moreover, due to its excellent patient acceptance, TE could be used for monitoring disease progression or predicting development of liver-related complications. This review aims at discussing the usefulness of TE in clinical practice.

  17. Transient thermal performance analysis of micro heat pipes

    International Nuclear Information System (INIS)

    Liu, Xiangdong; Chen, Yongping

    2013-01-01

    A theoretical analysis of transient fluid flow and heat transfer in a triangular micro heat pipes (MHP) has been conducted to study the thermal response characteristics. By introducing the system identification theory, the quantitative evaluation of the MHP's transient thermal performance is realized. The results indicate that the evaporation and condensation processes are both extended into the adiabatic section. During the start-up process, the capillary radius along axial direction of MHP decreases drastically while the liquid velocity increases quickly at the early transient stage and an approximately linear decrease in wall temperature arises along the axial direction. The MHP behaves as a first-order LTI control system with the constant input power as the 'step input' and the evaporator wall temperature as the 'output'. Two corresponding evaluation criteria derived from the control theory, time constant and temperature constant, are able to quantitatively evaluate the thermal response speed and temperature level of MHP under start-up, which show that a larger triangular groove's hydraulic diameter within 0.18–0.42 mm is able to accelerate the start-up and decrease the start-up temperature level of MHP. Additionally, the MHP starts up fastest using the fluid of ethanol and most slowly using the working fluid of methanol, and the start-up temperature reaches maximum level for acetone and minimum level for the methanol. -- Highlights: • Transient thermal response of micro heat pipe is simulated by an improved model. • Control theory is introduced to quantify the thermal response of micro heat pipe. • Evaluation criteria are proposed to represent thermal response of micro heat pipe. • Effects of groove dimensions and working fluids on start-up of micro heat pipe are evaluated

  18. Cerebrovascular instability in a subset of patients with stroke and transient ischemic attack.

    Science.gov (United States)

    Friberg, L; Olsen, T S

    1991-10-01

    In six patients, we observed remarkably unsteady blood flow and indications of vasospasms on the arteriolar level in connection with episodes of focal cerebral ischemia. The patients originated from a prospective consecutive study of 53 patients with stroke and transient ischemic attack who had been examined by cerebral angiography and rapidly repeated regional cerebral blood flow measurements using the intracarotid xenon 133 method. In 47 patients, regional cerebral blood flow values, flow patterns, and clinical condition were stable during the repeated regional cerebral blood flow measurements. In six patients, pronounced regional hypoperfusion and hyperperfusion developed during the course of examination. In the hypoperfused regions, flow was transiently reduced to values consistent with ischemia, and in four of these patients this was accompanied by transient neurological deficits. The arteriogram and isotope angiograms ruled out spasms of large arteries or thromboembolism. A condition of cerebrovascular instability on the arteriolar level probably was induced by the examination procedure. These patients were hypersensitive to the provoking stimuli either habitually or as a consequence of previous ischemic accidents. It is suggested that in some patients with focal cerebral ischemia, the primary cause might be spasms of the smallest resistance vessels rather than thromboembolism.

  19. Transient response of Salix cuttings to changing water level regimes

    Science.gov (United States)

    Gorla, L.; Signarbieux, C.; Turberg, P.; Buttler, A.; Perona, P.

    2015-03-01

    Sustainable water management requires an understanding of the effects of flow regulation on riparian ecomorphological processes. We investigated the transient response of Salix viminalis by examining the effect of water-level regimes on its above-ground and below-ground biomass. Four sets of Salix cuttings, three juveniles (in the first growing season) and one mature (1 year old), were planted and initially grown under the same water-level regime for 1 month. We imposed three different water-level regime treatments representing natural variability, a seasonal trend with no peaks, and minimal flow (characteristic of hydropower) consisting of a constant water level and natural flood peaks. We measured sap flux, stem water potential, photosynthesis, growth parameters, and final root architecture. The mature cuttings were not affected by water table dynamics, but the juveniles displayed causal relationships between the changing water regime, plant growth, and root distribution during a 2 month transient period. For example, a 50% drop in mean sap flux corresponded with a -1.5 Mpa decrease in leaf water potential during the first day after the water regime was changed. In agreement with published field observations, the cuttings concentrated their roots close to the mean water table of the corresponding treatment, allowing survival under altered conditions and resilience to successive stress events. Juvenile development was strongly impacted by the minimum flow regime, leading to more than 60% reduction of both above-ground and below-ground biomass, with respect to the other treatments. Hence, we suggest avoiding minimum flow regimes where Salix restoration is prioritized.

  20. Flow of Tunable Elastic Microcapsules through Constrictions

    OpenAIRE

    do Nascimento, D?bora F.; Avenda?o, Jorge A.; Mehl, Ana; Moura, Maria J. B.; Carvalho, Marcio S.; Duncanson, Wynter J.

    2017-01-01

    We design and fabricate elastically tunable monodisperse microcapsules using microfluidics and cross-linkable polydimethylsiloxane (PDMS). The overall stiffness of the microcapsules is governed by both the thickness and cross-link ratio of the polymer shell. Flowing suspensions of microcapsules through constricted spaces leads to transient blockage of fluid flow, thus altering the flow behavior. The ability to tune microcapsule mechanical properties enables the design of elastic microcapsules...