WorldWideScience

Sample records for transient absorption spectrometer

  1. Electro-Optical Multichannel Spectrometer for Transient Resonance Raman and Absorption Spectroscopy

    DEFF Research Database (Denmark)

    Hansen, Karina Benthin; Wilbrandt, Robert Walter; Pagsberg, Palle Bjørn

    1979-01-01

    An optical multichannel system is described, used for time‐dependent absorption measurements in the gas phase and the liquid phase and for resonance Raman spectroscopy of short‐lived transient species in the liquid phase in pulse radiolysis. It consists of either an image converter streak unit or...

  2. A transient absorption study of allophycocyanin

    Indian Academy of Sciences (India)

    Transient dynamics of allophycocyanin trimers and monomers are observed by using the pump-probe, transient absorption technique. The origin of spectral components of the transient absorption spectra is discussed in terms of both kinetics and spectroscopy. We find that the energy gap between the ground and excited ...

  3. Full-absorption scintillation spectrometer for neutrons

    International Nuclear Information System (INIS)

    Dzhelepov, V.P.; Filchenkov, V.V.; Konin, A.D.; Rudenko, A.I.; Solovieva, G.M.; Zinov, V.G.

    1988-01-01

    A full-absorption scintillation spectrometer for neutrons (volume of scintillator = 24 l) has been developed and employed in investigations of muon catalysed processes. Its application allows: (a) Considerably increasing the rate of accummulation of events; (b) efficiently using muon catalysis multiplicity for fuller and more reliable determination of its parameters; (c) significantly reducing uncertainty in the calculated and experimentally found values of neutron detection efficiency. The device combines good spectrometric properties for neutron energies E n = 1-6 MeV and reliable n-γ separation (the degree of separation for a Pu-Be source 3 starting from an electron energy of 50 keV). (orig.)

  4. Combined "dual" absorption and fluorescence smartphone spectrometers.

    Science.gov (United States)

    Arafat Hossain, Md; Canning, John; Ast, Sandra; Cook, Kevin; Rutledge, Peter J; Jamalipour, Abbas

    2015-04-15

    A combined "dual" absorption and fluorescence smartphone spectrometer is demonstrated. The optical sources used in the system are the white flash LED of the smartphone and an orthogonally positioned and interchangeable UV (λex=370  nm) and blue (λex=450  nm) LED. The dispersive element is a low-cost, nano-imprinted diffraction grating coated with Au. Detection over a 300 nm span with 0.42 nm/pixel resolution was carried out with the camera CMOS chip. By integrating the blue and UV excitation sources into the white LED circuitry, the entire system is self-contained within a 3D printed case and powered from the smartphone battery; the design can be scaled to add further excitation sources. Using a customized app, acquisition of absorption and fluorescence spectra are demonstrated using a blue-absorbing and green-emitting pH-sensitive amino-naphthalimide-based fluorescent probe and a UV-absorbing and blue-emitting Zn2+-sensitive fluoro-ionophore.

  5. A transient absorption study of allophycocyanin

    Indian Academy of Sciences (India)

    Unknown

    Experimental setup. The transient absorption (TA) experimental arrangement is shown in figure 1, and the ultrashort laser system is the same as used in our previous work.5 The pump energy is provided by the output of an OPA laser and attenuated to 30 nJ per pulse with a pulse duration time of 100 femtoseconds (fs) with ...

  6. Microwave spectrometer for the detection of transient gaseous species

    Energy Technology Data Exchange (ETDEWEB)

    Kolbe, W.F.; Zoellner, W.D.; Leskovar, B.

    1979-06-01

    A microwave spectrometer and associated apparatus for the detectin of unstable free radical species is described. The spectrometer, which operates over a frequency range from 66 to 73 GHz, consists of a tunable Fabry-Perot resonator followed by superhetrodyne detection for high sensitivity at low power levels. The resonator tuning is accomplished by means of a computer controlled stepping motor and by a piezoelectric transducer which also permits the use of source modulation and phase sensitive detection at 100 Hz. The sensitivity of the spectrometer is adequate to permit the detection of rotational transitions with absorption coefficients as small as 2 x 10/sup -9/ cm/sup -1/. The operation of the spectrometer is demonstrated by the detection of the two free radical species OH and SO. In the case of OH, a number of ..lambda..-doubling transitions, previously unobserved, are reported.

  7. Theory of strong-field attosecond transient absorption

    International Nuclear Information System (INIS)

    Wu, Mengxi; Chen, Shaohao; Camp, Seth; Schafer, Kenneth J; Gaarde, Mette B

    2016-01-01

    Attosecond transient absorption is one of the promising new techniques being developed to exploit the availability of sub-femtosecond extreme ultraviolet (XUV) pulses to study the dynamics of the electron on its natural time scale. The temporal resolution in a transient absorption setup comes from the control of the relative delay and coherence between pump and probe pulses, while the spectral resolution comes from the characteristic width of the features that are being probed. In this review we focus on transient absorption scenarios where an attosecond pulse of XUV radiation creates a broadband excitation that is subsequently probed by a few cycle infrared (IR) laser. Because the attosecond XUV pulses are locked to the IR field cycle, the exchange of energy in the laser–matter interaction can be studied with unprecedented precision. We focus on the transient absorption by helium atoms of XUV radiation around the first ionization threshold, where we can simultaneoulsy solve the time-dependent Schrödinger equation for the single atom response and the Maxwell wave equation for the collective response of the nonlinear medium. We use a time-domain method that allows us to treat on an equal footing all the different linear and nonlinear processes by which the medium can exchange energy with the fields. We present several simple models, based on a few-level system interacting with a strong IR field, to explain many of the novel features found in attosecond transient absorption spectrograms. These include the presence of light-induced states, which demonstrate the ability to probe the dressed states of the atom. We also present a time-domain interpretation of the resonant pulse propagation features that appear in absorption spectra in dense, macroscopic media. We close by reviewing several recent experimental results that can be explained in terms of the models we discuss. Our aim is to present a road map for understanding future attosecond transient absorption

  8. A novel multiplex absorption spectrometer for time-resolved studies

    Science.gov (United States)

    Lewis, Thomas; Heard, Dwayne E.; Blitz, Mark A.

    2018-02-01

    A Time-Resolved Ultraviolet/Visible (UV/Vis) Absorption Spectrometer (TRUVAS) has been developed that can simultaneously monitor absorption at all wavelengths between 200 and 800 nm with millisecond time resolution. A pulsed photolysis laser (KrF 248 nm) is used to initiate chemical reactions that create the target species. The absorption signals from these species evolve as the composition of the gas in the photolysis region changes over time. The instrument can operate at pressures over the range ˜10-800 Torr and can measure time-resolved absorbances systems (in particular the Herriott cell), there are fundamental differences, most notably the ability to adjust each mirror to maximise the overlap between the probe beam and the photolysis laser. Another feature which aids the sensitivity and versatility of the system is the use of 2 high-throughput spectrographs coupled with sensitive line-array CCDs, which can measure absorbance from ˜200 to 800 nm simultaneously. The capability of the instrument is demonstrated via measurements of the absorption spectrum of the peroxy radical, HOCH2CH2O2, and its self-reaction kinetics.

  9. Ultrafast transient-absorption of the solvated electron in water

    International Nuclear Information System (INIS)

    Kimura, Y.; Alfano, J.C.; Walhout, P.K.; Barbara, P.F.

    1994-01-01

    Ultrafast near infrared (NIR)-pump/variable wavelength probe transient-absorption spectroscopy has been performed on the aqueous solvated electron. The photodynamics of the solvated electron excited to its p-state are qualitatively similar to previous measurements of the dynamics of photoinjected electrons at high energy. This result confirms the previous interpretation of photoinjected electron dynamics as having a rate-limiting bottleneck at low energies presumably involving the p-state

  10. Transient Infrared Measurement of Laser Absorption Properties of Porous Materials

    Directory of Open Access Journals (Sweden)

    Marynowicz Andrzej

    2016-06-01

    Full Text Available The infrared thermography measurements of porous building materials have become more frequent in recent years. Many accompanying techniques for the thermal field generation have been developed, including one based on laser radiation. This work presents a simple optimization technique for estimation of the laser beam absorption for selected porous building materials, namely clinker brick and cement mortar. The transient temperature measurements were performed with the use of infrared camera during laser-induced heating-up of the samples’ surfaces. As the results, the absorbed fractions of the incident laser beam together with its shape parameter are reported.

  11. Developing quantum dot absorptive filter array based miniaturized spectrometer for space applications

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal is to developing a miniaturized shortwave infrared (SWIR) spectrometer that is based on quantum dot absorptive filter array. The important features of the...

  12. Femtosecond transient absorption spectroscopy of silanized silicon quantum dots

    Science.gov (United States)

    Kuntermann, Volker; Cimpean, Carla; Brehm, Georg; Sauer, Guido; Kryschi, Carola; Wiggers, Hartmut

    2008-03-01

    Excitonic properties of colloidal silicon quantum dots (Si qdots) with mean sizes of 4nm were examined using stationary and time-resolved optical spectroscopy. Chemically stable silicon oxide shells were prepared by controlled surface oxidation and silanization of HF-etched Si qdots. The ultrafast relaxation dynamics of photogenerated excitons in Si qdot colloids were studied on the picosecond time scale from 0.3psto2.3ns using femtosecond-resolved transient absorption spectroscopy. The time evolution of the transient absorption spectra of the Si qdots excited with a 150fs pump pulse at 390nm was observed to consist of decays of various absorption transitions of photoexcited electrons in the conduction band which overlap with both the photoluminescence and the photobleaching of the valence band population density. Gaussian deconvolution of the spectroscopic data allowed for disentangling various carrier relaxation processes involving electron-phonon and phonon-phonon scatterings or arising from surface-state trapping. The initial energy and momentum relaxation of hot carriers was observed to take place via scattering by optical phonons within 0.6ps . Exciton capturing by surface states forming shallow traps in the amorphous SiOx shell was found to occur with a time constant of 4ps , whereas deeper traps presumably localized in the Si-SiOx interface gave rise to exciton trapping processes with time constants of 110 and 180ps . Electron transfer from initially populated, higher-lying surface states to the conduction band of Si qdots (>2nm) was observed to take place within 400 or 700fs .

  13. Photoisomerization of ethyl ferulate: A solution phase transient absorption study

    Science.gov (United States)

    Horbury, Michael D.; Baker, Lewis A.; Rodrigues, Natércia D. N.; Quan, Wen-Dong; Stavros, Vasilios G.

    2017-04-01

    Ethyl ferulate (ethyl 4-hydroxy-3-methoxycinnamate) is currently used as a sunscreening agent in commercial sunscreen blends. Recent time-resolved gas-phase measurements have demonstrated that it possesses long-lived (>ns) electronic excited states, counterintuitive to what one might anticipate for an effective sunscreening agent. In the present work, the photodynamics of ethyl ferulate in cyclohexane, are explored using time-resolved transient electronic absorption spectroscopy, upon photoexcitation to the 11ππ∗ and 21ππ∗ states. We demonstrate that ethyl ferulate undergoes efficient non-radiative decay to repopulate the electronic ground state, mediated by trans-cis isomerization. These results strongly suggest that even mild perturbations induced by a non-polar solvent, as may be found in a closer-to-market sunscreen blend, may contribute to our understanding of ethyl ferulate's role as a sunscreening agent.

  14. DUVAS (derivative uv-absorption spectrometer): instrument description and operating manual

    International Nuclear Information System (INIS)

    Hawthorne, A.R.; Dougherty, J.M.; Metcalfe, C.E.

    1980-11-01

    DUVAS is a real-time, field-portable spectrometer capable of monitoring a variety of aromatic organic vapors and inorganic gases at sub-ppM concentrations. The instrument is a prototype, microcomputer-controlled, derivative ultraviolet (UV) absorption spectrometer (DUVAS) developed primarily for area monitoring at coal conversion facilities, although other important occupational and environmental monitoring applications for compounds such as SO 2 , NO/sub x/, NH 3 , and HCHO are also being pursued

  15. DUVAS (derivative uv-absorption spectrometer): instrument description and operating manual

    Energy Technology Data Exchange (ETDEWEB)

    Hawthorne, A.R.; Dougherty, J.M.; Metcalfe, C.E.

    1980-11-01

    DUVAS is a real-time, field-portable spectrometer capable of monitoring a variety of aromatic organic vapors and inorganic gases at sub-ppM concentrations. The instrument is a prototype, microcomputer-controlled, derivative ultraviolet (UV) absorption spectrometer (DUVAS) developed primarily for area monitoring at coal conversion facilities, although other important occupational and environmental monitoring applications for compounds such as SO/sub 2/, NO/sub x/, NH/sub 3/, and HCHO are also being pursued.

  16. A Fourier transform spectrometer for visible and near ultra-violet measurements of atmospheric absorption

    Science.gov (United States)

    Parsons, C. L.; Gerlach, J. C.; Whitehurst, M.

    1982-01-01

    The development of a prototype, ground-based, Sun-pointed Michelson interferometric spectrometer is described. Its intended use is to measure the atmospheric amount of various gases which absorb in the near-infrared, visible, and near-ultraviolet portions of the electromagnetic spectrum. Preliminary spectra which contain the alpha, 0.8 micrometer, and rho sigma tau water vapor absorption bands in the near-infrared are presented to indicate the present capability of the system. Ultimately, the spectrometer can be used to explore the feasible applications of Fourier transform spectroscopy in the ultraviolet where grating spectrometers were used exclusively.

  17. A high resolution x-ray fluorescence spectrometer for near edge absorption studies

    International Nuclear Information System (INIS)

    Stojanoff, V.; Hamalainen, K.; Siddons, D.P.; Hastings, J.B.; Berman, L.E.; Cramer, S.; Smith, G.

    1991-01-01

    A high resolution fluorescence spectrometer using a Johann geometry in a back scattering arrangement was developed. The spectrometer, with a resolution of 0.3 eV at 6.5 keV, combined with an incident beam, with a resolution of 0.7 eV, form the basis of a high resolution instrument for measuring x-ray absorption spectra. The advantages of the instrument are illustrated with the near edge absorption spectrum of dysprosium nitrate. 10 refs., 4 figs

  18. Generation dependent singlet–singlet annihilation within multichromophoric dendrimers studied by polychromatic transient absorption

    NARCIS (Netherlands)

    Jordens, Sven; Belder, Gino De; Lor, Marc; Schweitzer, Gerd; Auweraer, Mark Van der; Weil, Tanja; Herrmann, Andreas; Wiesler, Uwe-M.; Müllen, Klaus; Schryver, Frans C. De

    2003-01-01

    Intramolecular kinetic processes in a series of shape-persistent meta- and para-substituted polyphenylene dendrimers bearing different peryleneimide chromophores at the rim have been investigated using time-resolved polychromatic transient absorption measurements. The influence of the generation

  19. Characterization of a new modular decay total absorption gamma-ray spectrometer (DTAS) for FAIR

    International Nuclear Information System (INIS)

    Montaner Pizá, A.; Taín, J. L.; Agramunt, J.; Algora, A.; Guadilla, V.; Marín, E.; Rice, S.; Rubio, B.

    2013-01-01

    Beta-decay studies are one of the main goals of the DEcay SPECtroscopy experiment (DESPEC) to be installed at the future Facility for Antiproton and Ion Research (FAIR). DESPEC aims at the study of nuclear structure of exotic nuclei. A new modular Decay Total Absorption gamma-ray Spectrometer (DTAS) is being built at IFIC and is specially adapted to studies at fragmentation facilities such as the Super Fragment Separator (Super-FRS) at FAIR. The designed spectrometer is composed of 16 identical NaI(Tl) scintillation crystals. This work focuses on the characterization of these independent modules, as an initial step for the characterization of the full spectrometer. Monte Carlo simulations have been performed in order to understand the detector response.

  20. Characterization of a new modular decay total absorption gamma-ray spectrometer (DTAS) for FAIR

    Energy Technology Data Exchange (ETDEWEB)

    Montaner Piza, A.; Tain, J. L.; Agramunt, J.; Algora, A.; Guadilla, V.; Marin, E.; Rice, S.; Rubio, B. [Instituto de Fisica Corpuscular, CSIC-Univ. de Valencia, Apdo. Correos 22085, E-46071 Valencia (Spain)

    2013-06-10

    Beta-decay studies are one of the main goals of the DEcay SPECtroscopy experiment (DESPEC) to be installed at the future Facility for Antiproton and Ion Research (FAIR). DESPEC aims at the study of nuclear structure of exotic nuclei. A new modular Decay Total Absorption gamma-ray Spectrometer (DTAS) is being built at IFIC and is specially adapted to studies at fragmentation facilities such as the Super Fragment Separator (Super-FRS) at FAIR. The designed spectrometer is composed of 16 identical NaI(Tl) scintillation crystals. This work focuses on the characterization of these independent modules, as an initial step for the characterization of the full spectrometer. Monte Carlo simulations have been performed in order to understand the detector response.

  1. Characterization of a new modular decay total absorption gamma-ray spectrometer (DTAS) for FAIR

    Science.gov (United States)

    Pizá, A. Montaner; Taín, J. L.; Agramunt, J.; Algora, A.; Guadilla, V.; Marín, E.; Rice, S.; Rubio, B.

    2013-06-01

    Beta-decay studies are one of the main goals of the DEcay SPECtroscopy experiment (DESPEC) to be installed at the future Facility for Antiproton and Ion Research (FAIR). DESPEC aims at the study of nuclear structure of exotic nuclei. A new modular Decay Total Absorption gamma-ray Spectrometer (DTAS) is being built at IFIC and is specially adapted to studies at fragmentation facilities such as the Super Fragment Separator (Super-FRS) at FAIR. The designed spectrometer is composed of 16 identical NaI(Tl) scintillation crystals. This work focuses on the characterization of these independent modules, as an initial step for the characterization of the full spectrometer. Monte Carlo simulations have been performed in order to understand the detector response.

  2. Transient C IV broad absorption lines in radio-detected QSOs

    Science.gov (United States)

    Vivek, M.; Srianand, R.; Gupta, N.

    2016-01-01

    We study the transient (I.e. emerging or disappearing) C IV broad absorption line (BAL) components in 50 radio-detected QSOs using multi-epoch spectra available in Sloan Digital Sky Survey Data Release-10. We report the detection of six BALQSOs having at least one distinct transient C IV absorption component. Based on the structure function analysis of optical light curves, we suggest that the transient absorption is unlikely to be triggered by continuum variations. Transient absorption components usually have low C IV equivalent widths (10 000 km s-1) and typically occur over rest-frame time-scales >800 d. The detection rate of transient C IV absorption seen in our sample is higher than that reported in the literature. Using a control sample of QSOs, we show that this difference is most likely due to the longer monitoring time-scale of sources in our sample while the effect of small number statistics cannot be ignored. Thus, in order to establish the role played by radio jets in driving the BAL outflows, we need a larger sample of radio-detected BALs monitored over more than 3 yr in the QSO's rest frame. We also find that the transient phenomenon in radio-detected and radio-quiet BALs does not depend on any of the QSO properties, I.e. the Eddington ratio, black hole mass, bolometric luminosity and optical-to-IR colours. All this suggests that transient BAL phenomenon is simply the extreme case of BAL variability.

  3. Scanning Imaging Absorption Spectrometer for Atmospheric Chartography carbon monoxide total columns: Statistical evaluation and comparison with chemistry transport model results

    NARCIS (Netherlands)

    Laat, de A.T.J.; Gloudemans, A.M.S.; Aben, I.; Krol, M.C.; Meirink, J.F.; Werf, van der G.R.; Schrijver, H.

    2007-01-01

    This paper presents a detailed statistical analysis of one year (September 2003 to August 2004) of global Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY) carbon monoxide (CO) total column retrievals from the Iterative Maximum Likelihood Method (IMLM) algorithm,

  4. [Determination of sulfur in plant using a high-resolution continuum source atomic absorption spectrometer].

    Science.gov (United States)

    Wang, Yu; Li, Jia-xi

    2009-05-01

    A method for the analysis of sulfur (S) in plant by molecular absorption of carbon monosulfide (CS) using a high-resolution continuum source atomic absorption spectrometer (CS AAS) with a fuel-rich air/acetylene flame has been devised. The strong CS absorption band was found around 258 nm. The half-widths of some absorption bands were of the order of picometers, the same as the common atomic absorption lines. The experimental procedure in this study provided optimized instrumental conditions (the ratio of acetylene to air, the burner height) and parameters, and researched the spectral interferences and chemical interferences. The influence of the organic solvents on the CS absorption signals and the different digestion procedures for the determination of sulfur were also investigated. The limit of detection achieved for sulfur was 14 mg x L(-1), using the CS wavelength of 257. 961 nm and a measurement time of 3 s. The accuracy and precision were verified by analysis of two plant standard reference materials. The major applications of this method have been used for the determination of sulfur in plant materials, such as leaves. Compared to the others, this method for the analysis of sulfur is rapid, easy and simple for sulfur determination in plant.

  5. Beta strength distributions in neutron-deficient Kr and Sr isotopes using a total absorption spectrometer

    CERN Document Server

    Maréchal, F

    2003-01-01

    Far from the line of stability, beta -decay studies are often a primary source of information on nuclear structure. The measured beta -strength distribution for a given decay can be used to verify the accuracy of our theoretical description of the parent nucleus ground state and the states populated in the daughter nucleus. Total absorption spectrometers based on large NaI crystals are well suited tools to determine the beta -strength distribution over the whole Q /sub EC/ decay window. The newly built spectrometer TAgS, dedicated to such studies, is presented and its performances and possibilities are discussed in the light of experiments performed at the ISOLDE /CERN mass separator. The resulting information on ground state deformations for the /sup 74/Kr and /sup 76/Sr isotopes are discussed. (22 refs).

  6. Ultrafast time-resolved transient structures of solids and liquids by means of extended X-ray absorption fine structure.

    Science.gov (United States)

    Tomov, Ivan V; Rentzepis, Peter M

    2004-01-23

    Detection of ultrafast transient structures and the evolution of ultrafast structural intermediates during the course of reactions has been a long standing goal of chemists and biologists. This article will be restricted to nanosecond, picosecond and shorter time-resolved extended X-ray absorption fine structure (EXAFS) studies, its aim being to present the progress and problems encounter in measurements and understanding the structure of transients. The recent advances in source technology has stimulated a wide variety of novel experiments using both synchrotrons and smaller laboratory size systems. With more efficient X-ray lenses and detectors many of the previously difficult experiments to perform, because of the exposure time required and weak signals, will now be easily performed. The experimental system for the detection of ultrafast, time-resolved EXAFS spectra of molecules in liquids is described and the method for the analysis of EXAFS spectra to yield transient structures is given. We believe that utilizing our table-top ultrafast X-ray source and the polycapillary optics in conjunction with dispersive spectrometer and charge coupled devices (CCD) we will be able to determine the structure of many reaction intermediates and excited states of chemical and biological molecules in solid and liquid state.

  7. Excited-State Dynamics of Carotenoids Studied by Femtosecond Transient Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Lee, Ingu; Pang, Yoonsoo; Lee, Sebok

    2014-01-01

    Carotenoids, natural antenna pigments in photosynthesis share a symmetric backbone of conjugated polyenes. Contrary to the symmetric and almost planar geometries of carotenoids, excited state structure and dynamics of carotenoids are exceedingly complex. In this paper, recent infrared and visible transient absorption measurements and excitation dependent dynamics of 8'-apo-β-caroten-8'-al and 7',7'-dicyano-7'-apo-β-carotene will be reviewed. The recent visible transient absorption measurements of 8'-apo-β-caroten-8'-al in polar and nonpolar solvents will also be introduced to emphasize the complex excited-state dynamics and unsolved problems in the S 2 and S 1 excited states

  8. Predicting dermal absorption of gas-phase chemicals: transient model development, evaluation, and application

    DEFF Research Database (Denmark)

    Gong, M.; Zhang, Y.; Weschler, Charles J.

    2014-01-01

    A transient model is developed to predict dermal absorption of gas-phase chemicals via direct air-to-skin-to-blood transport under non-steady-state conditions. It differs from published models in that it considers convective mass-transfer resistance in the boundary layer of air adjacent to the skin....... Results calculated with this transient model are in good agreement with the limited experimental results that are available for comparison. The sensitivity of the modeled estimates to key parameters is examined. The model is then used to estimate air-to-skin-to-blood absorption of six phthalate esters...

  9. Recent Results From, and Future Plans for the JPL Carbon Dioxide Laser Absorption Spectrometer

    Science.gov (United States)

    Spiers, G. D.; Menzies, R.; Geier, S.; Phillips, M.

    2009-12-01

    The Carbon Dioxide Laser Absorption Spectrometer (CO2LAS) is an aircraft based Integrated Path Differential Absorption (IPDA) Spectrometer operating in the 2 micron wavelength range that we have been developing at JPL to evaluate the measurement of the column integrated carbon dioxide concentration beneath the aircraft. The IPDA measurement technique is based on an approach first used for the measurement of ozone in the 1970s. This past year the instrument has flown on two sets of flights aboard a Twin Otter, DH-6 aircraft. The initial pair of flights, conducted in April, were flown over the El Mirage dry lake bed in the Mojave desert as an engineering checkout flight. The second set of four flights were flown over the Southern Great Plains Atmospheric Research Monitoring Site during early August and were part of a larger coordinated field experiment conducted jointly with aircraft instruments from NASA LaRC and NASA GSFC in support of the development of the ASCENDS mission as called for by the NRC Earth Science Decadal Survey. We will present a brief overview of the instrument and measurement concept, review and discuss the results of our experiments and conclude with an outline of our plans for the future.

  10. Ultrafast terahertz conductivity and transient optical absorption spectroscopy of silicon nanocrystal thin films

    DEFF Research Database (Denmark)

    Titova, Lyubov V.; Harthy, Rahma Al; Cooke, David

    We use time-resolved THz spectroscopy and transient optical absorption spectroscopy as two complementary techniques to study ultrafast carrier dynamics in silicon nanocrystal thin films. We find that the photoconductive dynamics in these materials is dominated by interface trapping, and we observ...

  11. Optical imaging of non-fluorescent nanodiamonds in live cells using transient absorption microscopy.

    Science.gov (United States)

    Chen, Tao; Lu, Feng; Streets, Aaron M; Fei, Peng; Quan, Junmin; Huang, Yanyi

    2013-06-07

    We directly observe non-fluorescent nanodiamonds in living cells using transient absorption microscopy. This label-free technology provides a novel modality to study the dynamic behavior of nanodiamonds inside the cells with intrinsic three-dimensional imaging capability. We apply this method to capture the cellular uptake of nanodiamonds under various conditions, confirming the endocytosis mechanism.

  12. Estimation of damped oscillation associated spectra from ultrafast transient absorption spectra

    NARCIS (Netherlands)

    van Stokkum, Ivo; Jumper, Chanelle C.; Snellenburg, J.; Scholes, Gregory D.; van Grondelle, R.; Malý, P.

    2016-01-01

    When exciting a complex molecular system with a short optical pulse, all chromophores present in the system can be excited. The resulting superposition of electronically and vibrationally excited states evolves in time, which is monitored with transient absorption spectroscopy. We present a

  13. The photochemical ring opening reaction of chromene as seen by transient absorption and fluorescence spectroscopy

    NARCIS (Netherlands)

    Herzog, Teja T.; Ryseck, Gerald; Ploetz, Evelyn; Cordes, Thorben

    2013-01-01

    In this paper we investigate the photochromic ring-opening reaction of 2,2-diphenyl-5,6-benzo(2H)-chromene. In particular, we study the uncertainties and contradictions in various published reaction models using a combination of transient absorption and fluorescence spectroscopy with femtosecond

  14. spectrometer

    Directory of Open Access Journals (Sweden)

    J. K. Hedelius

    2016-08-01

    Full Text Available Bruker™ EM27/SUN instruments are commercial mobile solar-viewing near-IR spectrometers. They show promise for expanding the global density of atmospheric column measurements of greenhouse gases and are being marketed for such applications. They have been shown to measure the same variations of atmospheric gases within a day as the high-resolution spectrometers of the Total Carbon Column Observing Network (TCCON. However, there is little known about the long-term precision and uncertainty budgets of EM27/SUN measurements. In this study, which includes a comparison of 186 measurement days spanning 11 months, we note that atmospheric variations of Xgas within a single day are well captured by these low-resolution instruments, but over several months, the measurements drift noticeably. We present comparisons between EM27/SUN instruments and the TCCON using GGG as the retrieval algorithm. In addition, we perform several tests to evaluate the robustness of the performance and determine the largest sources of errors from these spectrometers. We include comparisons of XCO2, XCH4, XCO, and XN2O. Specifically we note EM27/SUN biases for January 2015 of 0.03, 0.75, –0.12, and 2.43 % for XCO2, XCH4, XCO, and XN2O respectively, with 1σ running precisions of 0.08 and 0.06 % for XCO2 and XCH4 from measurements in Pasadena. We also identify significant error caused by nonlinear sensitivity when using an extended spectral range detector used to measure CO and N2O.

  15. The nonlinear light output of NaI(Tl) detectors in the Modular Total Absorption Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Rasco, B.C., E-mail: crasco@lsu.edu [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Fijałkowska, A.; Karny, M. [Faculty of Physics, University of Warsaw, Pasteura 5, PL-02093 Warszawa (Poland); Rykaczewski, K.P. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Wolińska-Cichocka, M. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Oak Ridge Associated Universities, Oak Ridge, TN 37831 (United States); Heavy Ion Laboratory, University of Warsaw, Warsaw PL-02-093 (Poland); Grzywacz, R.; Goetz, K.C. [Department of Physics and Astronomy, University of Tennessee, Knoxville, TN 37966 (United States)

    2015-07-11

    A new detector array, the Modular Total Absorption Spectrometer (MTAS), was commissioned at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab (ORNL). Total absorption gamma spectra measured with MTAS are expected to improve beta-feeding patterns and beta strength functions in fission products. MTAS is constructed out of hexagonal NaI(Tl) detectors with a unique central module surrounded by 18 identical crystals assembled in three rings. The total NaI(Tl) mass of MTAS is over 1000 kg. The response of the central and other 18 MTAS modules to γ-radiation was simulated using the GEANT4 toolkit modified to analyze the nonlinear light output of NaI(Tl). A detailed description of the GEANT4 modifications made is discussed. Simulated energy resolution of MTAS modules is found to agree well with the measurements for single γ transitions of 662 keV ({sup 137}Cs) with 8.2% full width half maximum (FWHM), 835 keV ({sup 54}Mn) with FWHM of 7.5% FWHM, and 1115 keV ({sup 65}Zn) with FWHM of 6.5%. Simulations of single and multiple γ-rays from {sup 60}Co are also discussed.

  16. Dynamic Optoelectronic Properties in Perovskite Oxide Thin Films Measured with Ultrafast Transient Absorption & Reflectance Spectroscopy

    Science.gov (United States)

    Smolin, Sergey Y.

    Ultrafast transient absorption and reflectance spectroscopy are foundational techniques for studying photoexcited carrier recombination mechanisms, lifetimes, and charge transfer rates. Because quantifying photoexcited carrier dynamics is central to the intelligent design and improvement of many solid state devices, these transient optical techniques have been applied to a wide range of semiconductors. However, despite their promise, interpretation of transient absorption and reflectance data is not always straightforward and often relies on assumptions of physical processes, especially with respect to the influence of heating. Studying the material space of perovskite oxides, the careful collection, interpretation, and analysis of ultrafast data is presented here as a guide for future research into novel semiconductors. Perovskite oxides are a class of transition metal oxides with the chemical structure ABO3. Although traditionally studied for their diverse physical, electronic, and magnetic properties, perovskite oxides have gained recent research attention as novel candidates for light harvesting applications. Indeed, strong tunable absorption, unique interfacial properties, and vast chemical flexibility make perovskite oxides a promising photoactive material system. However, there is limited research characterizing dynamic optoelectronic properties, such as recombination lifetimes, which are critical to know in the design of any light-harvesting device. In this thesis, ultrafast transient absorption and reflectance spectroscopy was used to understand these dynamic optoelectronic properties in highquality, thin (gap of LFO at 2.4 eV and at the higher energy absorption edge at 3.5 eV. Using a combination of temperature-dependent, variable-angle spectroscopic ellipsometry and time-resolved ultrafast optical spectroscopy on a type I heterostructure, we clarify thermal and electronic contributions to spectral transients in LaFeO3. Upon comparison to thermally

  17. Excited-State Dynamics of Carotenoids Studied by Femtosecond Transient Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ingu; Pang, Yoonsoo [Department of Physics and Photon Science, Gwangju (Korea, Republic of); Lee, Sebok [Gwangju Institute of Science and Technology, Gwangju (Korea, Republic of)

    2014-03-15

    Carotenoids, natural antenna pigments in photosynthesis share a symmetric backbone of conjugated polyenes. Contrary to the symmetric and almost planar geometries of carotenoids, excited state structure and dynamics of carotenoids are exceedingly complex. In this paper, recent infrared and visible transient absorption measurements and excitation dependent dynamics of 8'-apo-β-caroten-8'-al and 7',7'-dicyano-7'-apo-β-carotene will be reviewed. The recent visible transient absorption measurements of 8'-apo-β-caroten-8'-al in polar and nonpolar solvents will also be introduced to emphasize the complex excited-state dynamics and unsolved problems in the S{sub 2} and S{sub 1} excited states.

  18. Charge Carrier Dynamics in Transition Metal Oxides Studied by Femtosecond Transient Extreme Ultraviolet Absorption Spectroscopy

    OpenAIRE

    Jiang, Chang-Ming

    2015-01-01

    With the ability to disentangle electronic transitions that occur on different elements and local electronic structures, time-resolved extreme ultraviolet (XUV) spectroscopy has emerged as a powerful tool for studying ultrafast dynamics in condensed phase systems. In this dissertation, a visible-pump/XUV-probe transient absorption apparatus with femtosecond resolution was constructed to investigate the carrier relaxation dynamics in semiconductors after photo-excitation. This includes timesca...

  19. Ultrafast transient absorption revisited: Phase-flips, spectral fingers, and other dynamical features

    Energy Technology Data Exchange (ETDEWEB)

    Cina, Jeffrey A., E-mail: cina@uoregon.edu; Kovac, Philip A. [Department of Chemistry and Biochemistry, and Oregon Center for Optical, Molecular, and Quantum Science, University of Oregon, Eugene, Oregon 97403 (United States); Jumper, Chanelle C. [Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6 (Canada); Dean, Jacob C.; Scholes, Gregory D., E-mail: gscholes@princeton.edu [Department of Chemistry, Princeton University, Princeton, New Jersey 08544 (United States)

    2016-05-07

    We rebuild the theory of ultrafast transient-absorption/transmission spectroscopy starting from the optical response of an individual molecule to incident femtosecond pump and probe pulses. The resulting description makes use of pulse propagators and free molecular evolution operators to arrive at compact expressions for the several contributions to a transient-absorption signal. In this alternative description, which is physically equivalent to the conventional response-function formalism, these signal contributions are conveniently expressed as quantum mechanical overlaps between nuclear wave packets that have undergone different sequences of pulse-driven optical transitions and time-evolution on different electronic potential-energy surfaces. Using this setup in application to a simple, multimode model of the light-harvesting chromophores of PC577, we develop wave-packet pictures of certain generic features of ultrafast transient-absorption signals related to the probed-frequency dependence of vibrational quantum beats. These include a Stokes-shifting node at the time-evolving peak emission frequency, antiphasing between vibrational oscillations on opposite sides (i.e., to the red or blue) of this node, and spectral fingering due to vibrational overtones and combinations. Our calculations make a vibrationally abrupt approximation for the incident pump and probe pulses, but properly account for temporal pulse overlap and signal turn-on, rather than neglecting pulse overlap or assuming delta-function excitations, as are sometimes done.

  20. First experiment with the NUSTAR/FAIR Decay Total Absorption γ -Ray Spectrometer (DTAS) at the IGISOL IV facility

    Science.gov (United States)

    Guadilla, V.; Algora, A.; Tain, J. L.; Agramunt, J.; Äystö, J.; Briz, J. A.; Cano-Ott, D.; Cucoanes, A.; Eronen, T.; Estienne, M.; Fallot, M.; Fraile, L. M.; Ganioglu, E.; Gelletly, W.; Gorelov, D.; Hakala, J.; Jokinen, A.; Jordan, D.; Kankainen, A.; Kolhinen, V.; Koponen, J.; Lebois, M.; Martinez, T.; Monserrate, M.; Montaner-Pizá, A.; Moore, I.; Nácher, E.; Orrigo, S.; Penttilä, H.; Podolyak, Zs.; Pohjalainen, I.; Porta, A.; Regan, P.; Reinikainen, J.; Reponen, M.; Rinta-Antila, S.; Rubio, B.; Rytkönen, K.; Shiba, T.; Sonnenschein, V.; Sonzogni, A. A.; Valencia, E.; Vedia, V.; Voss, A.; Wilson, J. N.; Zakari-Issoufou, A.-A.

    2016-06-01

    The new Decay Total Absorption Spectrometer (DTAS) has been commissioned with low energy radioactive beams at the upgraded IGISOL IV facility. The DTAS is a segmented detector composed of up to 18 NaI(Tl) crystals and it will be a key instrument in the DESPEC experiment at FAIR. In this document we report on the experimental setup and the first measurements performed with DTAS at IGISOL. The detector was characterized by means of MC simulations, and this allowed us to calculate the response function of the spectrometer and analyse the first cases of interest.

  1. Toxic metals distribution in different components of Pakistani and imported cigarettes by electrothermal atomic absorption spectrometer

    International Nuclear Information System (INIS)

    Kazi, T.G.; Jalbani, N.; Arain, M.B.; Jamali, M.K.; Afridi, H.I.; Sarfraz, R.A.; Shah, A.Q.

    2009-01-01

    It was extensively investigated that a significant flux of toxic metals, along with other toxins, reaches the lungs through smoking. In present study toxic metals (TMs) (Al, Cd, Ni and Pb) were determined in different components of Pakistani local branded and imported cigarettes, including filler tobacco (FT), filter (before and after normal smoking by a single volunteer) and ash by electrothermal atomic absorption spectrometer (ETAAS). Microwave-assisted digestion method was employed. The validity and accuracy of methodology were checked by using certified sample of Virginia tobacco leaves (ICHTJ-cta-VTL-2). The percentages (%) of TMs in different components of cigarette were calculated with respect to their total contents in FT of all branded cigarettes before smoking, while smoke concentration has been calculated by subtracting the filter and ash contents from the filler tobacco content of each branded cigarette. The highest percentage (%) of Al was observed in ash of all cigarettes, with range 97.3-99.0%, while in the case of Cd, a reverse behaviour was observed, as a range of 15.0-31.3% of total contents were left in the ash of all branded cigarettes understudy

  2. Toxic metals distribution in different components of Pakistani and imported cigarettes by electrothermal atomic absorption spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Kazi, T.G. [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: tgkazi@yahoo.com; Jalbani, N. [PCSIR Laboratories Karachi (Pakistan)], E-mail: nusratjalbani_21@yahoo.com; Arain, M.B. [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: bilal_KU2004@yahoo.com; Jamali, M.K. [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: mkhanjamali@yahoo.com; Afridi, H.I. [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: hassanimranafridi@yahoo.com; Sarfraz, R.A. [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: rajaadilsarfraz@gmail.com; Shah, A.Q. [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: aqshah07@yahoo.com

    2009-04-15

    It was extensively investigated that a significant flux of toxic metals, along with other toxins, reaches the lungs through smoking. In present study toxic metals (TMs) (Al, Cd, Ni and Pb) were determined in different components of Pakistani local branded and imported cigarettes, including filler tobacco (FT), filter (before and after normal smoking by a single volunteer) and ash by electrothermal atomic absorption spectrometer (ETAAS). Microwave-assisted digestion method was employed. The validity and accuracy of methodology were checked by using certified sample of Virginia tobacco leaves (ICHTJ-cta-VTL-2). The percentages (%) of TMs in different components of cigarette were calculated with respect to their total contents in FT of all branded cigarettes before smoking, while smoke concentration has been calculated by subtracting the filter and ash contents from the filler tobacco content of each branded cigarette. The highest percentage (%) of Al was observed in ash of all cigarettes, with range 97.3-99.0%, while in the case of Cd, a reverse behaviour was observed, as a range of 15.0-31.3% of total contents were left in the ash of all branded cigarettes understudy.

  3. Measurement of the Spectral Absorption of Liquid Water in Melting Snow With an Imaging Spectrometer

    Science.gov (United States)

    Green, Robert O.; Dozier, Jeff

    1995-01-01

    Melting of the snowpack is a critical parameter that drives aspects of the hydrology in regions of the Earth where snow accumulates seasonally. New techniques for measurement of snow melt over regional scales offer the potential to improve monitoring and modeling of snow-driven hydrological processes. In this paper we present the results of measuring the spectral absorption of liquid water in a melting snowpack with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). AVIRIS data were acquired over Mammoth Mountain, in east central California on 21 May 1994 at 18:35 UTC. The air temperature at 2926 m on Mammoth Mountain at site A was measured at 15-minute intervals during the day preceding the AVIRIS data acquisition. At this elevation. the air temperature did not drop below freezing the night of the May 20 and had risen to 6 degrees Celsius by the time of the overflight on May 21. These temperature conditions support the presence of melting snow at the surface as the AVIRIS data were acquired.

  4. Transient Photoinduced Absorption in Ultrathin As-grown Nanocrystalline Silicon Films

    Directory of Open Access Journals (Sweden)

    Lioutas Ch

    2007-01-01

    Full Text Available AbstractWe have studied ultrafast carrier dynamics in nanocrystalline silicon films with thickness of a few nanometers where boundary-related states and quantum confinement play an important role. Transient non-degenerated photoinduced absorption measurements have been employed to investigate the effects of grain boundaries and quantum confinement on the relaxation dynamics of photogenerated carriers. An observed long initial rise of the photoinduced absorption for the thicker films agrees well with the existence of boundary-related states acting as fast traps. With decreasing the thickness of material, the relaxation dynamics become faster since the density of boundary-related states increases. Furthermore, probing with longer wavelengths we are able to time-resolve optical paths with faster relaxations. This fact is strongly correlated with probing in different points of the first Brillouin zone of the band structure of these materials.

  5. Use of ruthenium dyes for subnanosecond detector fidelity testing in real time transient absorption

    Energy Technology Data Exchange (ETDEWEB)

    Byrdin, Martin; Thiagarajan, Viruthachalam; Villette, Sandrine; Espagne, Agathe; Brettel, Klaus [CEA, IBITECS, Laboratoire de Photocatalyse et Biohydrogene, F-91191 Gif-sur-Yvette, France and CNRS, URA 2096, F-91191 Gif-sur-Yvette (France)

    2009-04-15

    Transient absorption spectroscopy is a powerful tool for the study of photoreactions on time scales from femtoseconds to seconds. Typically, reactions slower than {approx}1 ns are recorded by the ''classical'' technique; the reaction is triggered by an excitation flash, and absorption changes accompanying the reaction are recorded in real time using a continuous monitoring light beam and a detection system with sufficiently fast response. The pico- and femtosecond region can be accessed by the more recent ''pump-probe'' technique, which circumvents the difficulties of real time detection on a subnanosecond time scale. This is paid for by accumulation of an excessively large number of shots to sample the reaction kinetics. Hence, it is of interest to extend the classical real time technique as far as possible to the subnanosecond range. In order to identify and minimize detection artifacts common on a subnanosecond scale, like overshoot, ringing, and signal reflections, rigorous testing is required of how the detection system responds to fast changes of the monitoring light intensity. Here, we introduce a novel method to create standard signals for detector fidelity testing on a time scale from a few picoseconds to tens of nanoseconds. The signals result from polarized measurements of absorption changes upon excitation of ruthenium complexes {l_brace}[Ru(bpy){sub 3}]{sup 2+} and a less symmetric derivative{r_brace} by a short laser flash. Two types of signals can be created depending on the polarization of the monitoring light with respect to that of the excitation flash: a fast steplike bleaching at magic angle and a monoexponentially decaying bleaching for parallel polarizations. The lifetime of the decay can be easily varied via temperature and viscosity of the solvent. The method is applied to test the performance of a newly developed real time transient absorption setup with 300 ps time resolution and high sensitivity.

  6. Fusion of Ultraviolet-Visible and Infrared Transient Absorption Spectroscopy Data to Model Ultrafast Photoisomerization.

    Science.gov (United States)

    Debus, Bruno; Orio, Maylis; Rehault, Julien; Burdzinski, Gotard; Ruckebusch, Cyril; Sliwa, Michel

    2017-08-03

    Ultrafast photoisomerization reactions generally start at a higher excited state with excess of internal vibrational energy and occur via conical intersections. This leads to ultrafast dynamics which are difficult to investigate with a single transient absorption spectroscopy technique, be it in the ultraviolet-visible (UV-vis) or infrared (IR) domain. On one hand, the information available in the UV-vis domain is limited as only slight spectral changes are observed for different isomers. On the other hand, the interpretation of vibrational spectra is strongly hindered by intramolecular relaxation and vibrational cooling. These limitations can be circumvented by fusing UV-vis and IR transient absorption spectroscopy data in a multiset multivariate curve resolution analysis. We apply this approach to describe the spectrodynamics of the ultrafast cis-trans photoisomerization around the C-N double bond observed for aromatic Schiff bases. Twisted intermediate states could be elucidated, and isomerization was shown to occur through a continuous complete rotation. More broadly, data fusion can be used to rationalize a vast range of ultrafast photoisomerization processes of interest in photochemistry.

  7. Use of interfacial layers to prolong hole lifetimes in hematite probed by ultrafast transient absorption spectroscopy

    Science.gov (United States)

    Paradzah, Alexander T.; Diale, Mmantsae; Maabong, Kelebogile; Krüger, Tjaart P. J.

    2018-04-01

    Hematite is a widely investigated material for applications in solar water oxidation due primarily to its small bandgap. However, full realization of the material continues to be hampered by fast electron-hole recombination rates among other weaknesses such as low hole mobility, short hole diffusion length and low conductivity. To address the problem of fast electron-hole recombination, researchers have resorted to growth of nano-structured hematite, doping and use of under-layers. Under-layer materials enhance the photo-current by minimising electron-hole recombination through suppressing of back electron flow from the substrate, such as fluorine-doped tin oxide (FTO), to hematite. We have carried out ultrafast transient absorption spectroscopy on hematite in which Nb2O5 and SnO2 materials were used as interfacial layers to enhance hole lifetimes. The transient absorption data was fit with four different lifetimes ranging from a few hundred femtoseconds to a few nanoseconds. We show that the electron-hole recombination is slower in samples where interfacial layers are used than in pristine hematite. We also develop a model through target analysis to illustrate the effect of under-layers on electron-hole recombination rates in hematite thin films.

  8. Carrier Formation Dynamics in Prototypical Organic Solar Cells as Investigated by Transient Absorption Spectroscopy

    Directory of Open Access Journals (Sweden)

    Yutaka Moritomo

    2016-01-01

    Full Text Available Subpicosecond transient absorption spectroscopy is a powerful tool used to clarify the exciton and carrier dynamics within the organic solar cells (OSCs. In this review article, we introduce a method to determine the absolute numbers of the excitons and carriers against delay time (t only from the photoinduced absorption (PIA and electrochemically induced absorption (EIA spectra. Application of this method to rr-P3HT-, PTB7-, and SMDPPEH-based OSCs revealed common aspects of the carrier formation dynamics. First, the temporal evolution of the numbers of the excitons and carriers indicates that the late decay component of exciton does not contribute to the carrier formation process. This is probably because the late component has not enough excess energy to separate into the electron and hole across the donor/acceptor (D/A interface. Secondly, the spectroscopy revealed that the exciton-to-carrier conversion process is insensitive to temperature. This observation, together with the fast carrier formation time in OSCs, is consistent with the hot exciton picture.

  9. Attosecond transient-absorption dynamics of xenon core-excited states in a strong driving field

    Science.gov (United States)

    Kobayashi, Yuki; Timmers, Henry; Sabbar, Mazyar; Leone, Stephen R.; Neumark, Daniel M.

    2017-03-01

    We present attosecond transient-absorption experiments on xenon 4 d-16 p core-level states resonantly driven by intense (1.6 ×1014W/cm 2 ) few-cycle near-infrared laser pulses. In this strongly driven regime, broad induced absorption features with half-cycle (1.3-fs) delay-dependent modulation are observed over the range of 58-65 eV, predicted as a signature of the breakdown of the rotating-wave approximation in strong-field driving of Autler-Townes splitting [A. N. Pfeiffer and S. R. Leone, Phys. Rev. A 85, 053422 (2012), 10.1103/PhysRevA.85.053422]. Relevant atomic states are identified by a numerical model involving three electronic states, and the mechanism behind the broad induced absorption is discussed in the Floquet formalism. These results demonstrate that a near-infrared field well into the tunneling regime can still control the optical properties of an atomic system over a several-electron-volt spectral range and with attosecond precision.

  10. Transient absorption and luminescence spectra of K9 glass at sub-damage site by ultraviolet laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Z., E-mail: namezhangzhen@126.com [Science and Technology on Plasma Physics Laboratory, Research Center of Laser Fusion (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610000 (China); Huang, J.; Geng, F.; Zhou, X.Y. [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Feng, S.Q. [Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610000 (China); Cheng, X.L., E-mail: chengxl@scu.edu.cn [Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610000 (China); Jiang, X.D. [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Wu, W.D. [Science and Technology on Plasma Physics Laboratory, Research Center of Laser Fusion (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610000 (China); Zheng, W.G.; Tang, Y.J. [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China)

    2014-01-01

    Highlights: • Transient absorption and luminescence spectra at sub-damage site of K9 glass by laser irradiation at 355 nm are presented. • As the energy density increases to 2.54 J/cm{sup 2}, the absorption intensity reaches to about 0.2. • The mechanism of two-photon ionization mainly plays a critical role at sub-damage site. • Intensity of Raman spectra is very high at low energy density and decreased with respect to high energy density. -- Abstract: Transient absorption and luminescence spectra at sub-damage site of K9 glass by laser irradiation at 355 nm are presented. The dependence of transient absorption on laser energy and number of pulses was investigated. As the energy density increases to 2.54 and 3.18 J/cm{sup 2}, the transient absorption intensity reaches to about 0.20 range from 400 to 480 nm. With the increase of number of pulses the process of residual absorption appears, which can be used to explain the fatigue effect of K9 glass. The defects in K9 glass were investigated by fluorescence and Raman spectra. The fluorescence band centered at about 410 nm is attributed to oxygen deficiency centers. The mechanism of two-photon ionization plays a critical role at sub-damage site. Compared to the Raman spectra of pristine site, intensity of Raman spectra is very high at a lower energy density, while it decreased at a higher energy density.

  11. Monolithic Chip-Integrated Absorption Spectrometer from 3-5 microns, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A monolithically integrated indium phosphide (InP) to silicon-on-sapphire (SoS) platform is being proposed for a monolithic portable or handheld spectrometer between...

  12. A Compact Tunable Diode Laser Absorption Spectrometer to Monitor CO2 at 2.7 µm Wavelength in Hypersonic Flows

    Directory of Open Access Journals (Sweden)

    Raphäel Vallon

    2010-06-01

    Full Text Available Since the beginning of the Mars planet exploration, the characterization of carbon dioxide hypersonic flows to simulate a spaceship’s Mars atmosphere entry conditions has been an important issue. We have developed a Tunable Diode Laser Absorption Spectrometer with a new room-temperature operating antimony-based distributed feedback laser (DFB diode laser to characterize the velocity, the temperature and the density of such flows. This instrument has been tested during two measurement campaigns in a free piston tunnel cold hypersonic facility and in a high enthalpy arc jet wind tunnel. These tests also demonstrate the feasibility of mid-infrared fiber optics coupling of the spectrometer to a wind tunnel for integrated or local flow characterization with an optical probe placed in the flow.

  13. Attosecond transient absorption spectrum of argon at the L2 ,3 edge

    Science.gov (United States)

    Chew, Andrew; Douguet, Nicolas; Cariker, Coleman; Li, Jie; Lindroth, Eva; Ren, Xiaoming; Yin, Yanchun; Argenti, Luca; Hill, Wendell T.; Chang, Zenghu

    2018-03-01

    Progress in high-harmonic generation has led to high-energy attosecond pulses with cutoff above the carbon 1 s edge (283.8 eV). These pulses are essential to extend time-resolved spectroscopies to the water window in order to control electron dynamics in solvated organic species. Here we report a step towards this goal: the measurement, with subcycle time resolution, of the attosecond transient absorption spectrum of argon at the 2 p-1 L2 ,3 edge (˜250 eV) in the presence of a short-wave infrared control pulse. The measurements, supported by theoretical simulations, demonstrate the concurrent role of Auger decay and tunnel ionization in the driven evolution of inner-valence holes of polyelectronic atoms.

  14. An Attosecond Transient Absorption Spectroscopy Setup with a Water Window Attosecond source

    Science.gov (United States)

    Chew, Andrew; Yin, Yanchun; Li, Jie; Ren, Xiaoming; Wang, Yang; Wu, Yi; Chang, Zenghu

    2017-04-01

    Attosecond transient absorption, or time-resolved pump-probe spectroscopy, are excellent tools that can be used to investigate fast electron dynamics for a given atomic or molecular system. Recent push for high energy long wavelength few cycle laser sources has resulted in the production of x-ray spectra that would allow the probing of electron dynamics at the carbon k-edge in molecules such as CH4 and CO2. The motion of charges can be caused by photo-dissociation and charge migration. We present here the first results from our experimental setup where we produce a broadband attosecond pulse with spectra that stretches into the water window. National Science Foundation (1068604), Army Research Oce (W911NF-14-1-0383), Air Force Oce of Scientic Research (FA9550-15-1-0037, FA9550-16-1-0013) and the DARPA PULSE program by a Grant from AMRDEC (W31P4Q1310017).

  15. Charge Carrier Dynamics of Quantum Confined Semiconductor Nanoparticles Analyzed via Transient Absorption Spectroscopy

    Science.gov (United States)

    Thibert, Arthur Joseph, III

    Semiconductor nanoparticles are tiny crystalline structures (typically range from 1 - 100 nm) whose shape in many cases can be dictated through tailored chemical synthesis with atomic scale precision. The small size of these nanoparticles often results in quantum confinement (spatial confinement of wave functions), which imparts the ability to manipulate band-gap energies thus allowing them to be optimally engineered for different applications (i.e., photovoltaics, photocatalysis, imaging). However, charge carriers excited within these nanoparticles are often involved in many different processes: trapping, trap migration, Auger recombination, non-radiative relaxation, radiative relaxation, oxidation / reduction, or multiple exciton generation. Broadband ultrafast transient absorption laser spectroscopy is used to spectrally resolve the fate of excited charge carriers in both wavelength and time, providing insight as to what synthetic developments or operating conditions will be necessary to optimize their efficiency for certain applications. This thesis outlines the effort of resolving the dynamics of excited charge carriers for several Cd and Si based nanoparticle systems using this experimental technique. The thesis is organized into five chapters and two appendices as indicated below. Chapter 1 provides a brief introduction to the photophysics of semiconductor nanoparticles. It begins by defining what nanoparticles, semiconductors, charge carriers, and quantum confinement are. From there it details how the study of charge carrier dynamics within nanoparticles can lead to increased efficiency in applications such as photocatalysis. Finally, the experimental methodology associated with ultrafast transient absorption spectroscopy is introduced and its power in mapping charge carrier dynamics is established. Chapter 2 (JPCC, 19647, 2011) introduces the first of the studied samples: water-solubilized 2D CdSe nanoribbons (NRs), which were synthesized in the Osterloh

  16. Ultrafast dynamics of two copper bis-phenanthroline complexes measured by x-ray transient absorption spectroscopy

    DEFF Research Database (Denmark)

    Kelley, Matthew S.; Shelby, Megan L.; Mara, Michael W.

    2017-01-01

    Ultrafast structural dynamics of the metal to ligand charge transfer (MLCT) states of two copper bis-phenanthroline complexes were captured by using x-ray transient absorption (XTA) spectroscopy at the Linac Coherent Light Source and further described by theoretical calculations. These complexes......(I)(dpps)2]+ possesses two bulky phenyl-sulfonate groups attached to each phen ligand that force the molecule to adopt a flattened tetrahedral geometry in the ground state. Previously, optical transient absorption (OTA) and synchrotron based XTA experiments with 100 ps time resolution have been employed...

  17. First experiment with the NUSTAR/FAIR Decay Total Absorption γ-Ray Spectrometer (DTAS) at the IGISOL IV facility

    OpenAIRE

    Guadilla, V.; Algora, A.; Tain, J.L.; Agramunt, J.; Äystö, Juha; Briz, A.; Cano-Ott, D.; Cucoanes, A.; Eronen, Tommi; Estienne, M.; Faillot, M.; Fraile, L.M.; Ganioglu, E.; Gelletly, W.; Gorelov, Dmitry

    2016-01-01

    The new Decay Total Absorption Spectrometer (DTAS) has been commissioned with low energy radioactive beams at the upgraded IGISOL IV facility. The DTAS is a segmented detector composed of up to 18 NaI(Tl) crystals and it will be a key instrument in the DESPEC experiment at FAIR. In this document we report on the experimental setup and the first measurements performed with DTAS at IGISOL. The detector was characterized by means of MC simulations, and this allowed us to calculate th...

  18. Ultrafast transient absorption studies of hematite nanoparticles: the effect of particle shape on exciton dynamics.

    Science.gov (United States)

    Fitzmorris, Bob C; Patete, Jonathan M; Smith, Jacqueline; Mascorro, Xiomara; Adams, Staci; Wong, Stanislaus S; Zhang, Jin Z

    2013-10-01

    Much progress has been made in using hematite (α-Fe2 O3 ) as a potentially practical and sustainable material for applications such as solar-energy conversion and photoelectrochemical (PEC) water splitting; however, recent studies have shown that the performance can be limited by a very short charge-carrier diffusion length or exciton lifetime. In this study, we performed ultrafast studies on hematite nanoparticles of different shapes to determine the possible influence of particle shape on the exciton dynamics. Nanorice, multifaceted spheroidal nanoparticles, faceted nanocubes, and faceted nanorhombohedra were synthesized and characterized by using SEM and XRD techniques. Their exciton dynamics were investigated by using femtosecond transient absorption (TA) spectroscopy. Although the TA spectral features differ for the four samples studied, their decay profiles are similar, which can be fitted with time constants of 1-3 ps, approximately 25 ps, and a slow nanosecond component extending beyond the experimental time window that was measured (2 ns). The results indicate that the overall exciton lifetime is weakly dependent on the shape of the hematite nanoparticles, even though the overall optical absorption and scattering are influenced by the particle shape. This study suggests that other strategies need to be developed to increase the exciton lifetime or to lengthen the exciton diffusion length in hematite nanostructures. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Microfluidic Integration on Detector Array for Absorption and Fluorescence Micro-Spectrometers

    National Research Council Canada - National Science Library

    Adam, Mark L; Enzelberger, Markus; Quake, Stephen; Scherer, Axel

    2005-01-01

    .... Elastomers are excellent transparent materials, which provide hermetic seals to silicon dioxide and allow sensitive absorption and fluorescent spectroscopy in the visible and near-UV wavelength range...

  20. Intermolecular interaction of photoexcited Cu(/TMpy-P4) with water studied by transient resonance Raman and picosecond absorption spectroscopies

    NARCIS (Netherlands)

    Kruglik, S.; Kruglik, Sergei G.; Ermolenkov, Vladimir V.; Shvedko, Alexander G.; Orlovich, Valentine A.; Galievsky, Victor A.; Chirvony, Vladimir S.; Otto, Cornelis; Turpin, Pierre-Yves

    1997-01-01

    photoinduced complex between Cu(TMpy-P4) and water molecules, reversibly axially coordinated to the central metal, was observed in picosecond transient absorption and nanosecond resonance Raman experiments. This complex is rapidly created (τ1 = 15 ± 5 ps) in the excited triplet (π, π*) state of

  1. Understanding charge carrier relaxation processes in terbium arsenide nanoparticles using transient absorption spectroscopy

    Science.gov (United States)

    Vanderhoef, Laura R.

    Erbium arsenide nanoparticles epitaxially grown within III-V semiconductors have been shown to improve the performance of devices for applications ranging from thermoelectrics to THz pulse generation. The small size of rare-earth nanoparticles suggests that interesting electronic properties might emerge as a result of both spatial confinement and surface states. However, ErAs nanoparticles do not exhibit any signs of quantum confinement or an emergent bandgap, and these experimental observations are understood from theory. The incorporation of other rare-earth monopnictide nanoparticles into III-V hosts is a likely path to engineering carrier excitation, relaxation and transport dynamics for optoelectronic device applications. However, the electronic structure of these other rare-earth monopnictide nanoparticles remains poorly understood. The objective of this research is to explore the electronic structure and optical properties of III-V materials containing novel rare-earth monopnictides. We use ultrafast pump-probe spectroscopy to investigate the electronic structure of TbAs nanoparticles in III-V hosts. We start with TbAs:GaAs, which was expected to be similar to ErAs:GaAs. We study the dynamics of carrier relaxation into the TbAs states using optical pump terahertz probe transient absorption spectroscopy. By analyzing how the carrier relaxation rates depend on pump fluence and sample temperature, we conclude that the TbAs states are saturable. Saturable traps suggest the existence of a bandgap for TbAs nanoparticles, in sharp contrast with previous results for ErAs. We then apply the same experimental technique to two samples of TbAs nanoparticles in InGaAs with different concentrations of TbAs. We observe similar relaxation dynamics associated with trap saturation, though the ability to resolve these processes is contingent upon a high enough TbAs concentration in the sample. We have also constructed an optical pump optical probe transient absorption

  2. Charge Carrier Dynamics in Transition Metal Oxides Studied by Femtosecond Transient Extreme Ultraviolet Absorption Spectroscopy

    Science.gov (United States)

    Jiang, Chang-Ming

    With the ability to disentangle electronic transitions that occur on different elements and local electronic structures, time-resolved extreme ultraviolet (XUV) spectroscopy has emerged as a powerful tool for studying ultrafast dynamics in condensed phase systems. In this dissertation, a visible-pump/XUV-probe transient absorption apparatus with femtosecond resolution was constructed to investigate the carrier relaxation dynamics in semiconductors after photo-excitation. This includes timescales for carrier thermalization by carrier-carrier and carrier-phonon scattering. The 30 -- 72 eV photon energy coverage (17 -- 40 nm wavelength) generated by a table-top XUV light source is suitable for probing the 3p-to-3d core level absorptions of various transition metal oxides (TMOs) with specificities to elements and oxidation states. In Chapter 1, a brief introduction to charge carrier dynamics in semiconductor-based materials is given. In addition, fundamentals of core-level spectroscopy and the high harmonic generation (HHG) process are also addressed in this introductory chapter. Specifications of the experimental apparatus that was constructed are summarized in Chapter 2, including the design concepts and characterization of performance. Chapter 3 presents the spectral tunability of the XUV pulses generated from a semi-infinite gas cell (SIGC), as well as the data acquisition procedures. Charge carrier relaxation dynamics in Co3O4 following the charge transfer excitation pathway at 400 nm are documented in Chapter 4. In Chapter 5, various visible pump wavelengths are used to excite Co3O4 and the differences in the carrier dynamics versus excitation wavelength are considered. After selectively photoexciting a Si/TiO2 heterojunction, the resulted electron transfer process is observed and reported in Chapter 6. The concluding remarks of the dissertation are made in Chapter 7, while several ongoing time-resolved experiments are addressed in the Appendix sections.

  3. High energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline.

    Science.gov (United States)

    Llorens, Isabelle; Lahera, Eric; Delnet, William; Proux, Olivier; Braillard, Aurélien; Hazemann, Jean-Louis; Prat, Alain; Testemale, Denis; Dermigny, Quentin; Gelebart, Frederic; Morand, Marc; Shukla, Abhay; Bardou, Nathalie; Ulrich, Olivier; Arnaud, Stéphan; Berar, Jean-François; Boudet, Nathalie; Caillot, Bernard; Chaurand, Perrine; Rose, Jérôme; Doelsch, Emmanuel; Martin, Philippe; Solari, Pier Lorenzo

    2012-06-01

    Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute systems in environmental, material and biological sciences. The spectrometer has been designed to be a mobile device for easy integration in multi-purpose hard x-ray synchrotron beamlines or even with a laboratory x-ray source. The CAS allows to collect x-ray photons from a large solid angle with five spherically bent crystals. It will cover a large energy range allowing to probe fluorescence lines characteristic of all the elements from Ca (Z = 20) to U (Z = 92). It provides an energy resolution of 1-2 eV. XAS spectroscopy is the main application of this device even if other spectroscopic techniques (RIXS, XES, XRS, etc.) can be also achieved with it. The performances of the CAS are illustrated by two experiments that are difficult or impossible to perform with SSD and the complementarity of the CAS vs SSD detectors is discussed.

  4. Ultrafast holography and transient absorption spectroscopy in charge-transfer polymers

    Energy Technology Data Exchange (ETDEWEB)

    McBranch, D.W.; Maniloff, E.S. [Los Alamos National Lab., NM (United States); Vacar, D.; Heeger, A.J. [Univ. of California, Santa Barbara, CA (United States). Institute for Polymers and Organic Solids

    1997-10-01

    Charge-transfer polymers are a new class of nonlinear optical materials which can be used for generating femtosecond holographic gratings. Using semiconducting polymers sensitized with varying concentrations of C{sub 60}, holographic gratings were recorded by individual ultrafast laser pulses; the diffraction efficiency and time decay of the gratings were measured using non-degenerate four-wave mixing. Using a figure of merit for dynamic data processing, the temporal diffraction efficiency, this new class of materials exhibits between two and 12 orders of magnitude higher response than previous reports. The charge transfer range at polymer/C{sub 60} interfaces was further studied using transient absorption spectroscopy. The fact that charge-transfer occurs in the picosecond-time scale in bilayer structures (thickness 200 {angstrom}) implies that diffusion of localized excitations to the interface is not the dominant mechanism; the charge transfer range is a significant fraction of the film thickness. From analysis of the excited state decay curves, we estimate the charge transfer range to be 80 {angstrom} and interpret that range as resulting from quantum delocalization of the photoexcitations.

  5. Ultrafast Transient Absorption Spectroscopy of Polymer-Based Organophotoredox Catalysts Mimicking Transition-Metal Complexes

    Science.gov (United States)

    Jamhawi, Abdelqader; Paul, Anam C.; Smith, Justin D.; Handa, Sachin; Liu, Jinjun

    2017-06-01

    Transition-metal complexes of rare earth metals including ruthenium and iridium are most commonly employed as visible-light photocatalysts. Despite their highly important and broad applications, they have many disadvantages including high cost associated with low abundance in earth crust, potential toxicity, requirement of specialized ligands for desired activity, and difficulty in recycling of metal contents as well as associated ligands. Polymer-based organophotoredox catalysts are promising alternatives and possess unique advantages such as easier synthesis from inexpensive starting material, longer excited state life time, broad range of activity, sustainability, and recyclability. In this research talk, time-resolved photoluminescence and femtosecond transient absorption (TA) spectroscopy measurements of three novel polymer-based organophotoredox catalysts will be presented. By our synthetic team, their catalytic activity has been proven in some highly valuable chemical transformations, that otherwise require transition metal complexes. Time-resolved spectroscopic investigations have demonstrated that photoinduced processes in these catalysts are similar to the transition metal complexes. Especially, intramolecular vibrational relaxation, internal conversion, and intersystem crossing from the S1 state to the T1 state all occur on a sub-picosecond timescale. The long lifetime of the T1 state ( 2-3 microsecond) renders these polymers potent oxidizing and reducing agents. A spectroscopic and kinetic model has been developed for global fitting of TA spectra in both the frequency and time domains. Implication of the current ultrafast spectroscopy studies of these novel molecules to their roles in photocatalysis will be discussed.

  6. Excited-State Dynamics of Melamine and Its Lysine Derivative Investigated by Femtosecond Transient Absorption Spectroscopy

    Directory of Open Access Journals (Sweden)

    Yuyuan Zhang

    2016-11-01

    Full Text Available Melamine may have been an important prebiotic information carrier, but its excited-state dynamics, which determine its stability under UV radiation, have never been characterized. The ability of melamine to withstand the strong UV radiation present on the surface of the early Earth is likely to have affected its abundance in the primordial soup. Here, we studied the excited-state dynamics of melamine (a proto-nucleobase and its lysine derivative (a proto-nucleoside using the transient absorption technique with a UV pump, and UV and infrared probe pulses. For melamine, the excited-state population decays by internal conversion with a lifetime of 13 ps without coupling significantly to any photochemical channels. The excited-state lifetime of the lysine derivative is slightly longer (18 ps, but the dominant deactivation pathway is otherwise the same as for melamine. In both cases, the vast majority of excited molecules return to the electronic ground state on the aforementioned time scales, but a minor population is trapped in a long-lived triplet state.

  7. Quantification of CO2 and CH4 megacity emissions using portable solar absorption spectrometers

    Science.gov (United States)

    Frey, Matthias; Hase, Frank; Blumenstock, Thomas; Morino, Isamu; Shiomi, Kei

    2017-04-01

    Urban areas already contribute to over 50% of the global population, additionally the percentage of the worldwide population living in Metropolitan areas is continuously growing. Thus, a precise knowledge of urban greenhouse gas (GHG) emissions is of utmost importance. Whereas, however, GHG emissions on a nationwide to continental scale can be relatively precisely estimated using satellite observations (and fossil fuel consumption statistics), reliable estimations for local to regional scale emissions pose a bigger problem due to lack of timely and spatially high resolved satellite data and possible biases of passive spectroscopic nadir observations (e.g. enhanced aerosol scattering in a city plume). Furthermore, emission inventories on the city scale might be missing contributions (e.g. methane leakage from gas pipes). Here, newly developed mobile low resolution Fourier Transform spectrometers (Bruker EM27/SUN) are utilized to quantify small scale emissions. This novel technique was successfully tested before by KIT and partners during campaigns in Berlin, Paris and Colorado for detecting emissions from various sources. We present results from a campaign carried out in February - April 2016 in the Tokyo bay area, one of the biggest Metropolitan areas worldwide. We positioned two EM27/SUN spectrometers on the outer perimeter of Tokyo along the prevailing wind axis upwind and downwind of the city source. Before and after the campaign, calibration measurements were performed in Tsukuba with a collocated high resolution FTIR spectrometer from the Total Carbon Column Observing Network (TCCON). During the campaign the observed XCO2 and XCH4 values vary significantly. Additionally, intraday variations are observed at both sites. Furthermore, an enhancement due to the Tokyo area GHG emissions is clearly visible for both XCO2 and XCH4. The observed signals are significantly higher compared to prior campaigns targeting other major cities. We perform a rough estimate of the

  8. Transient absorption and luminescence spectra of K9 glass at sub-damage site by ultraviolet laser irradiation

    Science.gov (United States)

    Zhang, Z.; Huang, J.; Geng, F.; Zhou, X. Y.; Feng, S. Q.; Cheng, X. L.; Jiang, X. D.; Wu, W. D.; Zheng, W. G.; Tang, Y. J.

    2014-01-01

    Transient absorption and luminescence spectra at sub-damage site of K9 glass by laser irradiation at 355 nm are presented. The dependence of transient absorption on laser energy and number of pulses was investigated. As the energy density increases to 2.54 and 3.18 J/cm2, the transient absorption intensity reaches to about 0.20 range from 400 to 480 nm. With the increase of number of pulses the process of residual absorption appears, which can be used to explain the fatigue effect of K9 glass. The defects in K9 glass were investigated by fluorescence and Raman spectra. The fluorescence band centered at about 410 nm is attributed to oxygen deficiency centers. The mechanism of two-photon ionization plays a critical role at sub-damage site. Compared to the Raman spectra of pristine site, intensity of Raman spectra is very high at a lower energy density, while it decreased at a higher energy density.

  9. Annihilation limit of a visible-to-UV photon upconversion composition ascertained from transient absorption kinetics.

    Science.gov (United States)

    Deng, Fan; Blumhoff, Jörg; Castellano, Felix N

    2013-05-30

    Noncoherent sensitized green-to-near-visible upconversion has been achieved utilizing palladium(II) octaethylporphyrin (PdOEP) as the triplet sensitizer and anthracene as the energy acceptor/annihilator in vacuum degassed toluene. Selective 547 nm excitation of PdOEP with incident irradiance as low as 600 μW/cm(2) results in the observation of anthryl fluorescence at higher energy. Stern-Volmer analysis of the dynamic phosphorescence quenching of PdOEP by anthracene possesses an extremely large K(SV) of 810,000 M(-1), yielding a triplet-triplet energy transfer quenching constant of 3.3 × 10(9) M(-1) s(-1). Clear evidence for the subsequent triplet-triplet annihilation (TTA) of anthracene was afforded by numerous experiments, one of the most compelling was an excitation scan illustrating that the Q-band absorption features of PdOEP are solely responsible for sensitizing the anti-Stokes fluorescence. The upconverted emission intensity with respect to the excitation power was shown to vary between quadratic and linear using either coherent or noncoherent light sources, illustrating the expected kinetic limits for the light producing photochemistry under continuous wave illumination. Time-resolved experiments directly comparing the total integrated anthracene intensity/time fluorescence data produced through upconversion (λ(ex) = 547 nm, delayed signal) and with direct excitation (λ(ex) = 355 nm, prompt signal) under conditions where the laser pulse is completely absorbed by the sample reveal annihilation efficiencies of approximately 40%. Similarly, the delayed fluorescence kinetic analysis reported by Schmidt and co-workers (J. Phys. Chem. Lett. 2010, 1, 1795-1799) was used to reveal the maximum possible efficiency from a model red-to-yellow upconverting composition and this treatment was applied to the anthryl triplet absorption decay transients of anthracene measured for the PdOEP/anthracene composition at 430 nm. From this analysis approximately 50% of the

  10. Improved Carrier Transport in Perovskite Solar Cells Probed by Femtosecond Transient Absorption Spectroscopy.

    Science.gov (United States)

    Serpetzoglou, Efthymis; Konidakis, Ioannis; Kakavelakis, George; Maksudov, Temur; Kymakis, Emmanuel; Stratakis, Emmanuel

    2017-12-20

    CH 3 NH 3 PbI 3 perovskite thin films have been deposited on glass/indium tin oxide/hole transport layer (HTL) substrates, utilizing two different materials as the HTLs. In the first configuration, the super hydrophilic polymer poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate), known as PEDOT:PSS, was employed as the HTL material, whereas in the second case, the nonwetting poly(triarylamine) semiconductor polymer, known as PTAA, was used. It was found that when PTAA is used as the HTL material, the averaged power conversion efficiency (PCE) of the perovskite solar cells (PSCs) remarkably increases from 12.60 to 15.67%. To explore the mechanism behind this enhancement, the aforementioned perovskite/HTL arrangements were investigated by time-resolved transient absorption spectroscopy (TAS) performed under inert conditions. By means of TAS, the charge transfer, carrier trapping, and hole injection dynamics from the photoexcited perovskite layers to the HTL can be directly monitored via the characteristic bleaching profile of the perovskite at ∼750 nm. TAS studies revealed faster relaxation times and decay dynamics when the PTAA polymer is employed, which potentially account for the enhanced PCE observed. The TAS results are correlated with the structure and crystalline quality of the corresponding perovskite films, investigated by scanning electron microscopy, X-ray diffraction, atomic force microscopy, micro-photoluminescence, and transmittance spectroscopy. It is concluded that TAS is a benchmark technique for the understanding of the carrier transport mechanisms in PSCs and constitutes a figure-of-merit tool toward their efficiency improvement.

  11. Femtosecond Visible Transient Absorption Spectroscopy of Chlorophyll f-Containing Photosystem I.

    Science.gov (United States)

    Kaucikas, Marius; Nürnberg, Dennis; Dorlhiac, Gabriel; Rutherford, A William; van Thor, Jasper J

    2017-01-24

    Photosystem I (PSI) from Chroococcidiopsis thermalis PCC 7203 grown under far-red light (FRL; >725 nm) contains both chlorophyll a and a small proportion of chlorophyll f. Here, we investigated excitation energy transfer and charge separation using this FRL-grown form of PSI (FRL-PSI). We compared femtosecond transient visible absorption changes of normal, white-light (WL)-grown PSI (WL-PSI) with those of FRL-PSI using excitation at 670 nm, 700 nm, and (in the case of FRL-PSI) 740 nm. The possibility that chlorophyll f participates in energy transfer or charge separation is discussed on the basis of spectral assignments. With selective pumping of chlorophyll f at 740 nm, we observe a final ∼150 ps decay assigned to trapping by charge separation, and the amplitude of the resulting P700 +• A 1 -• charge-separated state indicates that the yield is directly comparable to that of WL-PSI. The kinetics shows a rapid 2 ps time constant for almost complete transfer to chlorophyll f if chlorophyll a is pumped with a wavelength of 670 nm or 700 nm. Although the physical role of chlorophyll f is best supported as a low-energy radiative trap, the physical location should be close to or potentially within the charge-separating pigments to allow efficient transfer for charge separation on the 150 ps timescale. Target models can be developed that include a branching in the formation of the charge separation for either WL-PSI or FRL-PSI. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  12. Femtosecond coherent nuclear dynamics of excited tetraphenylethylene: Ultrafast transient absorption and ultrafast Raman loss spectroscopic studies

    Science.gov (United States)

    Kayal, Surajit; Roy, Khokan; Umapathy, Siva

    2018-01-01

    Ultrafast torsional dynamics plays an important role in the photoinduced excited state dynamics. Tetraphenylethylene (TPE), a model system for the molecular motor, executes interesting torsional dynamics upon photoexcitation. The photoreaction of TPE involves ultrafast internal conversion via a nearly planar intermediate state (relaxed state) that further leads to a twisted zwitterionic state. Here, we report the photoinduced structural dynamics of excited TPE during the course of photoisomerization in the condensed phase by ultrafast Raman loss (URLS) and femtosecond transient absorption (TA) spectroscopy. TA measurements on the S1 state reveal step-wise population relaxation from the Franck-Condon (FC) state → relaxed state → twisted state, while the URLS study provides insights on the vibrational dynamics during the course of the reaction. The TA spectral dynamics and vibrational Raman amplitudes within 1 ps reveal vibrational wave packet propagating from the FC state to the relaxed state. Fourier transformation of this oscillation leads to a ˜130 cm-1 low-frequency phenyl torsional mode. Two vibrational marker bands, Cet=Cet stretching (˜1512 cm-1) and Cph=Cph stretching (˜1584 cm-1) modes, appear immediately after photoexcitation in the URLS spectra. The initial red-shift of the Cph=Cph stretching mode with a time constant of ˜400 fs (in butyronitrile) is assigned to the rate of planarization of excited TPE. In addition, the Cet=Cet stretching mode shows initial blue-shift within 1 ps followed by frequency red-shift, suggesting that on the sub-picosecond time scale, structural relaxation is dominated by phenyl torsion rather than the central Cet=Cet twist. Furthermore, the effect of the solvent on the structural dynamics is discussed in the context of ultrafast nuclear dynamics and solute-solvent coupling.

  13. Total absorption gamma-ray spectrometer for measurement of beta-decay intensity distributions for fission product radionuclides

    International Nuclear Information System (INIS)

    Greenwood, R.C.; Helmer, R.G.; Lee, M.A.; Putnam, M.H.; Oates, M.A.; Struttmann, D.A.; Watts, K.D.

    1992-01-01

    A total absorption γ-ray spectrometer (TAGS), based on a 25.4 cm diameterx30.5 cm long NaI(Tl) well detector, has been developed at the INEL on-line isotope separator facility. A Si detector in the well of the NaI(Tl) detector allows one to collect β-particle-gated coincidence spectra as well as singles spectra. With this system, measurements of the total absorption spectra have been made for a number of fission product nuclei. The analysis of the measured spectra is based on response functions for single γ rays that are computed with a Monte Carlo code. Routines have been written to use these response functions to simulate the response to a cascade of several γ rays and by extension to a whole decay scheme. The bremsstrahlung from a ground-state β branch can also be simulated. The quality of the simulation is demonstrated for test spectra of 137 Cs, 24 Na, 60 Co, and 110m Ag. As examples of the operation of this system, the measurements and analyses of the β-decay feeding distributions are described for the decay of 141 Ba, 139 Cs and 140 Cs. (orig.)

  14. A prototype stationary Fourier transform spectrometer for near-infrared absorption spectroscopy.

    Science.gov (United States)

    Li, Jinyang; Lu, Dan-feng; Qi, Zhi-mei

    2015-09-01

    A prototype stationary Fourier transform spectrometer (FTS) was constructed with a fiber-coupled lithium niobate (LiNbO3) waveguide Mach-Zehnder interferometer (MZI) for the purpose of rapid on-site spectroscopy of biological and chemical measurands. The MZI contains push-pull electrodes for electro-optic modulation, and its interferogram as a plot of intensity against voltage was obtained by scanning the modulating voltage from -60 to +60 V in 50 ms. The power spectrum of input signal was retrieved by Fourier transform processing of the interferogram combined with the wavelength dispersion of half-wave voltage determined for the MZI used. The prototype FTS operates in the single-mode wavelength range from 1200 to 1700 nm and allows for reproducible spectroscopy. A linear concentration dependence of the absorbance at λmax = 1451 nm for water in ethanolic solution was obtained using the prototype FTS. The near-infrared spectroscopy of solid samples was also implemented, and the different spectra obtained with different materials evidenced the chemical recognition capability of the prototype FTS. To make this prototype FTS practically applicable, work on improving its spectral resolution by increasing the maximum optical path length difference is in progress.

  15. A comparison of NO2 absorption measurements from an FTIR spectrometer and the OSIRIS spectrograph

    International Nuclear Information System (INIS)

    Puckrin, E.; Evans, W.F.J.

    2007-01-01

    The optical spectrograph and infrared imager system (OSIRIS) aboard the Odin satellite was part of Canada's contribution to the international joint venture of this satellite project. OSIRIS is used for aeronomic studies, including the study of stratospheric ozone (O 3 ) depletion and transport dynamics. It collects limb-view spectra of the scattered sunlight in the ultraviolet-visible region and measures the column abundance of ozone, nitrogen dioxide (NO 2 ) and other trace constituents in the atmosphere. Vertical concentration profiles are then generated for these gases. In this study, spectral measurements of the transmission of a gas cell filled with various amounts of NO 2 were obtained with two instruments, a Fourier-transform infrared (FTIR) spectrometer and the OSIRIS spectrograph of the grating type. Five different gas-cell concentrations were examined in an effort to calibrate the OSIRIS instrument in the 400 to 700 nm region where NO 2 absorbs visible radiation. The NO 2 column amounts derived from the OSIRIS measurements ranged from 6.05 x 10 17 to 1.17 x 10 16 molecules/cm 2 , and agreed within 10 per cent of the values determined from the FTIR measurements. It was concluded that the OSIRIS spectrograph is well suited for the remote sensing of atmospheric NO 2 . 13 refs., 2 tabs., 5 figs

  16. Limiting Short-term Noise versus Optical Density in a Direct Absorption Spectrometer for Trace Gas Detection

    Science.gov (United States)

    Jervis, D.

    2016-12-01

    Field-deployable trace gas monitors are important for understanding a multitude of atmospheric processes: from forest photosynthesis and respiration [1], to fugitive methane emissions [2] and satellite measurement validation [3]. Consequently, a detailed knowledge of the performance limitations of these instruments is essential in order to establish reliable datasets. We present the short-term ( >1 Hz) performance of a long-pass direct absorption spectrometer as a function of the optical density of the absorption transition being probed. In particular, we identify fluctuations in the laser intensity as limiting the optical density uncertainty to 4x10-6/√Hz for weak transitions, and noise in the laser drive current as limiting the fractional noise in the optical density to 4x10-5/√Hz for deep transitions. We provide numerical and analytical predictions for both effects, as well as using the understanding of this phenomena to estimate how noise on neighboring strong and weak transitions couple to each other. All measurements were performed using the Aerodyne Research TILDAS Monitor, but are general to any instrument that uses direct absorption spectroscopy as a detection method. Wehr, R., et al. "Seasonality of temperate forest photosynthesis and daytime respiration." Nature 534.7609 (2016): 680-683. Conley, S., et al. "Methane emissions from the 2015 Aliso Canyon blowout in Los Angeles, CA." Science 351.6279 (2016): 1317-1320. Emmons, L. K., et al. "Validation of Measurements of Pollution in the Troposphere (MOPITT) CO retrievals with aircraft in situ profiles." Journal of Geophysical Research: Atmospheres 109.D3 (2004).

  17. XUV Transient Absorption Spectroscopy: Probing Laser-Perturbed Dipole Polarization in Single Atom, Macroscopic, and Molecular Regimes

    Directory of Open Access Journals (Sweden)

    Chen-Ting Liao

    2017-03-01

    Full Text Available We employ an extreme ultraviolet (XUV pulse to impulsively excite dipole polarization in atoms or molecules, which corresponds to coherently prepared superposition of excited states. A delayed near infrared (NIR pulse then perturbs the fast evolving polarization, and the resultant absorbance change is monitored in dilute helium, dense helium, and sulfur hexafluoride (SF6 molecules. We observe and quantify the time-dependence of various transient phenomena in helium atoms,includinglaser-inducedphase(LIP,time-varying(ACStarkshift,quantumpathinterference, and laser-induced continuum structure. In the case of dense helium targets, we discuss nonlinear macroscopic propagation effects pertaining to LIP and resonant pulse propagation, which accoun tfor the appearance of new spectral features in transient lineshapes. We then use tunable NIR photons to demonstrate the wavelength dependence of the transient laser induced effects. In the case of molecular polarization experiment in SF6, we show suppression of XUV photoabsorption corresponding to inter-valence transitions in the presence of a strong NIR field. In each case, the temporal evolution of transient absorption spectra allows us to observe and understand the transient laser induced modifications of the electronic structure of atoms and molecules.

  18. Ultraviolet part of transient absorption spectrum induced in liquid ammonia by nanosecond pulse radiolysis

    International Nuclear Information System (INIS)

    Farhataziz

    1977-01-01

    The absorption spectra induced in neat liquid ammonia and ammoniacal solution of N 2 O by nanosecond pulse radiolysis have been measured for wavelength range 250 to 325 nm. The results indicate that the absorption spectrum induced in liquid ammonia is a composite of absorption spectra of e/sub am/ - and NH 2 . The absorptions due to e/sub am/ - decrease with decreasing wavelength, and are attributed to the tail of the absorption spectrum (maximum absorption in near infrared) of e/sub am/ - . The absorption spectrum for NH 2 has a shoulder at approximately 255 nm. In liquid ammonia at 23 0 C, the extinction coefficient for NH 2 at 250 nm is 1.1 x 10 3 M -1 cm -1

  19. [Ru(bpy)(3)](2+) as a reference in transient absorption spectroscopy: differential absorption coefficients for formation of the long-lived (3)MLCT excited state.

    Science.gov (United States)

    Müller, Pavel; Brettel, Klaus

    2012-04-01

    Transient absorption spectroscopy and other time-resolved methods are commonly used to study chemical reactions and biological processes induced by absorption of light. In order to scale the signal amplitude or to compare results obtained under different conditions, it is advisable to use a reference system, a standard of convenient and well-defined properties. Finding Tris(bipyridine)ruthenium(ii), [Ru(bpy)(3)](2+), a suitable candidate for a transient-absorption spectroscopy reference due to its favourable photochemical properties, we have determined accurate relative values of differential molar absorption coefficients (Δε) for light-induced formation of the metal-to-ligand charge transfer (MLCT) excited triplet state at several relevant wavelengths (wavelengths of commercially available lasers) in the UV and visible regions. We have also attempted to determine the absolute value of Δε close to the wavelength of maximum bleaching (∼450 nm) and we propose to narrow down the interval of conceivable values for Δε(450) from the broad range of published values (-0.88 × 10(4) M(-1)cm(-1) to -1.36 × 10(4) M(-1)cm(-1)) to -1.1 × 10(4) M(-1)cm(-1)± 15%. Having ourselves successfully applied [Ru(bpy)(3)](2+) as a standard in a recent time-resolved study of enzymatic DNA repair, we would like to encourage other scientists to use this convenient tool as a reference in their future spectroscopic studies on time scales from picoseconds to hundreds of nanoseconds.

  20. Laser induced transient absorptions of the excited triplet state of 9,10-anthraquinone-2-sulfonate. A further study by 248 nm laser photolysis

    International Nuclear Information System (INIS)

    Ma Jianhua; Lin Weizheng; Wang Wenfen; Yao Side; Lin Nianyun

    1999-01-01

    Transient absorption spectrum of triplet state of 9,10-anthraquinone-2-sulfonate (AQS) in aqueous solution has been investigated using 248 nm (KrF) laser photolysis. A whole transient absorption spectrum with absorption maxim at 380 nm and 580 nm has been assigned to triple AQS from detailed kinetic analysis of decay of 380 nm and 580 nm signals, which is the neat characteristic absorption of triplet AQS reported for the first time. In addition, the difference in feature of the spectrum of triplet AQS in H 2 O and that in CH 3 CN was eliminated by further study using 248 nm laser pulses

  1. Absorption spectra of localized surface plasmon resonance observed in an inline/picoliter spectrometer cell fabricated by a near ultraviolet femtosecond laser

    Science.gov (United States)

    Shiraishi, Masahiko; Nishiyama, Michiko; Watanabe, Kazuhiro; Kubodera, Shoichi

    2018-03-01

    Absorption spectra based on localized surface plasmon resonance (LSPR) were obtained with an inline/picoliter spectrometer cell. The spectrometer cell was fabricated into an optical glass fiber by focusing a near UV (NUV) femtosecond laser pulses at a wavelength of 400 nm with an energy of 30 μJ. The laser beam was focused from two directions opposite to each other to fabricate a through-hole spectrometer cell. A diameter of the cell was approximately 3 μm, and the length was approximately 62.5 μm, which was nearly equal to the core diameter of the optical fiber. Liquid solution of gold nanoparticles (GNPs) with a diameter of 5-10 nm was injected into the spectrometer cell with its volume of 0.4 pL. The absorption peak centered at 518 nm was observed. An increase of absorption associated with the increase of the number of nanoparticles was in agreement with the numerical calculation based on the Lambert-Beer law.

  2. Studies of the $\\beta$-decay of Sr nuclei on and near the N=Z Line with a Total Absorption Gamma-ray Spectrometer

    CERN Multimedia

    Marechal, F; Caballero ontanaya, L

    2002-01-01

    In the framework of the investigation of the shapes of the ground states of the parent nucleus, we propose to carry out measurements of the complete Gamow-Teller strength distribution for the $^{76-80}$Sr isotopes, with a new Total Absorption Gamma Spectrometer installed on a new beam line. The results will be compared with theoretical calculations based on the mean field approach. A brief report on the IS370 experiment on $^{72-75}$Kr decay, which was recently performed at ISOLDE, will be given and the performance of the sum spectrometer will be presented.

  3. Wet/dry film thickness measurement of paint by absorption spectroscopy with acousto-optic tunable filter spectrometer

    Science.gov (United States)

    Sinha, Pranay G.; Xiong, Xiangchun; Jin, Feng; Trivedi, Sudhir; Prasad, Narashima S.

    2005-08-01

    Controlling/monitoring the thickness of applied paint in real time is important to many situations including painting ship and submarine hulls in dry docks for maintaining health of ships and submarines against the harshness of the sea, in automobile and aerospace industries, and in a variety of other industries as a control sensor that plays significant role in product quality, process control, and cost control. Insufficient thickness results to inadequate protection while overspray leads to waste and pollution of the environment. A rugged instrumentation for the real time non-contact accurate measurement of wet and dry paint film thickness measurement will be immensely valuable. As paint is applied with several layers of the same or different type, thickness of each newly sprayed wet layer is of most interest, but measurement on dry paint is also useful. In this study, we use acousto-optic tunable filter-based near infrared spectrometer to obtain the absorption spectrum of layers of paint sprayed on sand blasted steel surface and thus measure the thickness of coating under both wet and dry situations. NIR spectra are obtained from 1100 to 2300 nm on four sample of different thickness of paint up to 127 micron. Partial least squares model built with the spectra shows good correlation with standard error of prediction within ~ 0.7 micron. Results indicate that the spectra also respond to the amount of organic solvent in the wet paint and can be used to monitor the degree of dryness of the paint in real time.

  4. Initial investigation of the wavelength dependence of optical properties measured with a new multi-pass Aerosol Extinction Differential Optical Absorption Spectrometer (AE-DOAS

    Directory of Open Access Journals (Sweden)

    R. T. Chartier

    2012-04-01

    Full Text Available Atmospheric aerosols directly affect climate by scattering and absorbing radiation. The magnitude of the impact is dependent upon the wavelength of light, but is often estimated near 550 nm. When light scattering and absorption by aerosols is approximated, the wavelength dependence of the refractive index for specific components is lost. As a result, climate models would have inherent uncertainties for aerosol contributions to radiative forcing when considering the entire solar spectrum. An aerosol extinction differential optical absorption spectrometer has been developed to directly measure aerosol extinction at mid-ultraviolet to near infrared wavelengths. The instrument consists of a spectrometer coupled to a closed White-type multi-pass gas cell with an adjustable path length of up to approximately 20 m. Laboratory measurements of various gases are compared with known absorption cross sections. Additionally, the extinction of monodisperse samples of polystyrene latex spheres are measured and compared to Mie theory generated with refractive index values from the literature to validate the new instrument. The polystyrene experiments also emphasize the ability of the new instrument to retrieve the wavelength dependent refractive index, especially in the ultraviolet wavelength regions where variability is expected. The spectrometer will be a significant advancement for determining wavelength dependent complex refractive indices in future laboratory studies as well as provide the ability to monitor ambient aerosol light extinction.

  5. Hot Electron Photoemission from Plasmonic Nanoparticles: Role of Transient Absorption in Surface Mechanism

    DEFF Research Database (Denmark)

    Uskov, Alexander V.; Protsenko, Igor E.; Ikhsanov, Renat S.

    2014-01-01

    We analyze and compare surface- and vol ume-based internal photoelectric effects from spherical nanoparticles, obtaining analytical expression s for the photoemission rate in both cases. Similar to results for a flat metal surface, one can show that the surface mechanism preva ils, since it is un...... it is unaffected by detrimental hot electron collisions. Transient ab sorption results from dielectric permittivity discontinuity at the nanoparticle boundary and leads to a substantial (by ~5 times) increase of the photoelectron emission rate....

  6. Delayed electron relaxation in CdTe nanorods studied by spectral analysis of the ultrafast transient absorption

    Energy Technology Data Exchange (ETDEWEB)

    Kriegel, I., E-mail: ilka.kriegel@iit.it [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Scotognella, F. [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); CNST of IIT@POLIMI, Via Pascoli 70/3, 20133 Milano (Italy); Soavi, G. [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Brescia, R. [Department of Nanochemistry, Istituto Italiano di Tecnologia (IIT), via Morego 30, 16163 Genova (Italy); Rodríguez-Fernández, J.; Feldmann, J. [Photonics and Optoelectronics Group, Department of Physics and CeNS, Ludwig-Maximilians-Universität München, Amalienstr. 54, 80799 Munich (Germany); Nanosystems Initiative Munich (NIM), Schellingstr. 4, 80799 Munich (Germany); Lanzani, G., E-mail: guglielmo.lanzani@iit.it [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); CNST of IIT@POLIMI, Via Pascoli 70/3, 20133 Milano (Italy); Tassone, F. [CNST of IIT@POLIMI, Via Pascoli 70/3, 20133 Milano (Italy)

    2016-06-01

    Highlights: • We study the photophysics of CdTe nanorods by ultrafast absorption spectroscopy. • We fit photobleaching and photoinduced absorption features at all time delays. • Dynamics are extracted from superpositions of bleaches (Gaussians) and derivatives. • Fast non-radiative recombination and slower hole trapping processes are extracted. • A potential approach to unveil ultrafast non-radiative recombination processes. - Abstract: In transient absorption (TA) spectra, the bleach features originating from state filling are overlapped by their energy-shifted derivatives, arising from excited state energy level shifts. This makes the direct extraction of carrier dynamics from a single-wavelength time-trace misleading. Fitting TA spectra in time, as Gaussian functions and their derivative-like shifted Gaussians, allows to individually extract the real dynamics of both photobleached transitions, and their energy shifts. In CdTe nanorods (NRs) we found a delayed heating of holes due to the release of the large excess energy in the electron relaxation process. The slow hole-trapping process is consistent with a high number of surface trap states in these model NRs. Our results show that only a correct disentanglement of bleaching and energy shift contributions provides a reliable framework to extract the underlying carrier relaxation dynamics, including trapping, non-radiative recombination, and eventually carrier multiplication.

  7. Optimization of a solar driven absorption refrigerator in the transient regime

    International Nuclear Information System (INIS)

    Hamed, Mouna; Fellah, Ali; Ben Brahim, Ammar

    2012-01-01

    Highlights: ► Dynamic behavior of a solar absorption refrigerator endoreversible model. ► Using the principles of classical thermodynamics, mass and heat transfers. ► Minimizing heat exchange time to reach maximum performances. ► Major influence of the collector temperature on the model’s characteristics. ► Analogous effects of both the thermal load and the thermal conductance. -- Abstract: This contribution deals with the theoretical study in dynamic mode of an absorption refrigerator endoreversible model. The system is a cold generating station driven by solar energy. The main elements of the cycle are a refrigerated space, an absorption refrigerator and a solar collector form. A mathematical model is developed. It combines the classical thermodynamics and mass and heat transfers principles. The numerical simulation is made for different operating and conceptual conditions. A global minimizing time optimization is performed in view to reach maximum performances. Appropriate dimensionless groups are defined. The results are presented in normalized charts for general applications. The collector temperature presents major influence on the conceptual and functional characteristics compared to the stagnation temperature influence. On the other hand the thermal load in the refrigerated space and the thermal conductance of the walls has analogous effects, therefore important to be considered in actual design. As a result, the model is expected to be a useful tool for simulation, design, and optimization of solar collector based energy systems.

  8. Transient absorption spectroscopy studies on polythiophene-fullerene bulk heterojunction organic blend films sensitized with a low-bandgap polymer.

    Science.gov (United States)

    Löslein, Heiko; Ameri, Tayebeh; Matt, Gebhard J; Koppe, Markus; Egelhaaf, Hans J; Troeger, Anna; Sgobba, Vito; Guldi, Dirk M; Brabec, Christoph J

    2013-07-12

    Recently, the concept of near-infrared sensitization is successfully employed to increase the light harvesting in large-bandgap polymer-based solar cells. To gain deeper insights into the operation mechanism of ternary organic solar cells, a comprehensive understanding of charge transfer-charge transport in ternary blends is a necessity. Herein, P3HT:PCPDTBT:PCBM ternary blend films are investigated by transient absorption spectroscopy. Hole transfer from PCPDTBT-positive polarons to P3HT in the P3HT:PCPDTBT:PCBM 0.9:0.1:1 blend film can be visualized. This process evolves within 140 ps and is discussed with respect to the proposed charge-generation mechanisms. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Cationic effect on dye-sensitized solar cell properties using electrochemical impedance and transient absorption spectroscopy techniques

    Science.gov (United States)

    Gupta, Ravindra Kumar; Bedja, Idriss

    2017-06-01

    Redox-couple polymer electrolytes, (poly(ethylene oxide)-succinonitrile) blend/MI-I2, where M  =  Li or K, were prepared by the solution cast method. Owing to the plasticizing property of K+ ions, the K+ ion-based electrolyte exhibited better electrical conductivity than the Li+ ion-based electrolyte, which did however exhibit better photovoltaic properties. Electrochemical impedance spectroscopy revealed faster redox species diffusions and interfacial processes in the Li+ ion-based dye-sensitized solar cells than in the K+ ion-based ones. Transient absorption spectroscopy ascertained faster dye-regeneration by the Li+ ion-based electrolyte than the K+ ion-based electrolyte.

  10. Measurement of Urban Air Quality by an Open-Path Quantum Cascade Laser Absorption Spectrometer in Beijing During Summer 2008

    Science.gov (United States)

    Michel, A. P.; Liu, P. Q.; Yeung, J. K.; Zhang, Y.; Baeck, M. L.; Pan, X.; Dong, H.; Wang, Z.; Smith, J. A.; Gmachl, C. F.

    2009-05-01

    The 2008 Olympic Games focused attention on the air quality of Beijing, China and served as an important test-bed for developing, deploying, and testing new technologies for analysis of air quality and regional climate in urban environments. Poor air quality in urban locations has a significant detrimental effect on the health of residents while also impacting both regional and global climate change. As a result, there exists a great need for highly sensitive trace gas sensors for studying the atmosphere of the urban environment. Open-path remote sensors are of particular interest as they can obtain data on spatial scales similar to those used in regional climate models. Quantum cascade lasers (QCLs) can be designed for operation in the mid-infrared (mid-IR) with a central wavelength anywhere between 3 to 24 μm and made tunable over a wavelength interval of over 0.1 μm. The Quantum Cascade Laser Open-Path System (QCLOPS) is a mid-infrared laser absorption spectrometer that uses a tunable, thermoelectrically cooled, pulsed Daylight Solutions Inc. QCL for measurement of trace gases. The system is aimed at applications with path lengths ranging from approximately 0.1 to 1.0 km. The system is designed to continuously monitor multiple trace gases [water vapor (H2O), ozone (O3), ammonia (NH3), and carbon dioxide (CO2)] in the lower atmosphere. A field campaign from July to September 2008 in Beijing used QCLOPS to study trace gas concentrations before, during, and after the Olympic Games in an effort to capture changes induced by emissions reduction methods. QCLOPS was deployed at the Institute of Atmospheric Physics - Chinese Academy of Sciences on the roof of a two-story building, at an approximate distance of 2 miles from the Olympic National Stadium ("The Bird's Nest.") QCLOPS operated with an open-path round trip distance of approximately 75 m. The system ran with minimal human interference, twenty-four hours per day for the full campaign period. In order to

  11. Convergence Studies of Thermal and Electromagnetic Transient Quench Analysis of 11 GeV Super High Momentum Spectrometer Superconducting Magnets in Jefferson Lab

    International Nuclear Information System (INIS)

    Sun, Eric; Brindza, Paul; Lassiter, Steve; Fowler, Mike; Xu, E.

    2010-01-01

    This paper presents results of convergence studies of transient thermal and electromagnetic quench analysis of five Super High Momentum Spectrometer (SHMS) superconducting magnets: HB, Q1, Q2, Q3, and Dipole, using Vector Fields Quench analysis codes. The convergence of the hot spot temperature and solution solve times were used to investigate the effects of element types, mesh densities, and tolerance criteria. The comparisons between tetrahedral elements and hexahedral elements was studied, and their advantages and disadvantages were discussed. Based on the results of convergence studies, a meshing guideline for coils is presented. The impact of iteration tolerance to the hot spot temperature was also explored, and it is found that tight tolerances result in extremely long solve times with only marginal improvements in the results.

  12. A compact tunable diode laser absorption spectrometer to monitor CO2 at 2.7 μm wavelength in hypersonic flows.

    Science.gov (United States)

    Vallon, Raphäel; Soutadé, Jacques; Vérant, Jean-Luc; Meyers, Jason; Paris, Sébastien; Mohamed, Ajmal

    2010-01-01

    Since the beginning of the Mars planet exploration, the characterization of carbon dioxide hypersonic flows to simulate a spaceship's Mars atmosphere entry conditions has been an important issue. We have developed a Tunable Diode Laser Absorption Spectrometer with a new room-temperature operating antimony-based distributed feedback laser (DFB) diode laser to characterize the velocity, the temperature and the density of such flows. This instrument has been tested during two measurement campaigns in a free piston tunnel cold hypersonic facility and in a high enthalpy arc jet wind tunnel. These tests also demonstrate the feasibility of mid-infrared fiber optics coupling of the spectrometer to a wind tunnel for integrated or local flow characterization with an optical probe placed in the flow.

  13. Strong-field induced dissociation dynamics in 1,2-dibromoethane traced by femtosecond XUV transient absorption spectroscopy

    Science.gov (United States)

    Chatterley, A. S.; Lackner, F.; Neumark, D. M.; Leone, S. R.; Gessner, O.

    2016-05-01

    Strong field induced dissociation dynamics of the small haloalkane 1,2-dibromoethane (DBE) have been explored using femtosecond XUV transient absorption spectroscopy. Dynamics are initiated by a near IR pump pulse with intensities between 75 and 220 TW cm-2, and are probed by the atomic site specific XUV absorption of the Br 3d levels. Immediately upon ionization, the spectral signatures of molecular ions appear. These molecular peaks decay in tandem with the appearance of atomic Br peaks in charge states of 0, + 1 and + 2, which are all monitored simultaneously. Neutral Br atoms are eliminated in 300 fs, presumably from statistical dissociation of vibrationally hot DBE+ ions, Br+ ions are eliminated in 70 fs from a more energetic dissociative ionization pathway, and Br++ ions are eliminated within the duration of the 35 fs pump pulse. The simultaneous recording of multiple parent molecule and fragment ion traces enables new insight into predominant dissociation pathways induced by strong field ionization of organic molecules.

  14. Attosecond transient absorption instrumentation for thin film materials: Phase transitions, heat dissipation, signal stabilization, timing correction, and rapid sample rotation

    Science.gov (United States)

    Jager, Marieke F.; Ott, Christian; Kaplan, Christopher J.; Kraus, Peter M.; Neumark, Daniel M.; Leone, Stephen R.

    2018-01-01

    We present an extreme ultraviolet (XUV) transient absorption apparatus tailored to attosecond and femtosecond measurements on bulk solid-state thin-film samples, specifically when the sample dynamics are sensitive to heating effects. The setup combines methodology for stabilizing sub-femtosecond time-resolution measurements over 48 h and techniques for mitigating heat buildup in temperature-dependent samples. Single-point beam stabilization in pump and probe arms and periodic time-zero reference measurements are described for accurate timing and stabilization. A hollow-shaft motor configuration for rapid sample rotation, raster scanning capability, and additional diagnostics are described for heat mitigation. Heat transfer simulations performed using a finite element analysis allow comparison of sample rotation and traditional raster scanning techniques for 100 Hz pulsed laser measurements on vanadium dioxide, a material that undergoes an insulator-to-metal transition at a modest temperature of 340 K. Experimental results are presented confirming that the vanadium dioxide (VO2) sample cannot cool below its phase transition temperature between laser pulses without rapid rotation, in agreement with the simulations. The findings indicate the stringent conditions required to perform rigorous broadband XUV time-resolved absorption measurements on bulk solid-state samples, particularly those with temperature sensitivity, and elucidate a clear methodology to perform them.

  15. Ultrafast Transient Absorption Spectroscopy Investigation of Photoinduced Dynamics in Novel Donor-Acceptor Core-Shell Nanostructures for Organic Photovoltaics

    Science.gov (United States)

    Strain, Jacob; Jamhawi, Abdelqader; Abeywickrama, Thulitha M.; Loomis, Wendy; Rathnayake, Hemali; Liu, Jinjun

    2016-06-01

    Novel donor-acceptor nanostructures were synthesized via covalent synthesis and/or UV cross-linking method. Their photoinduced dynamics were investigated with ultrafast transient absorption (TA) spectroscopy. These new nanostructures are made with the strategy in mind to reduce manufacturing steps in the process of fabricating an organic photovoltaic cell. By imitating the heterojunction interface within a fixed particle domain, several fabrication steps can be bypassed reducing cost and giving more applicability to other film deposition methods. Such applications include aerosol deposition and ink-jet printing. The systems that were studied by TA spectroscopy include PDIB core, PDIB-P3HT core-shell, and PDIB-PANT core-shell which range in size from 60 to 130 nm. Within the experimentally accessible spectra range there resides a region of ground state bleaching, stimulated emission, and excited-state absorption of both neutrals and anions. Control experiments have been carried out to assign these features. At high pump fluences the TA spectra of PDIB core alone also indicate an intramolecular charge separation. The TA spectroscopy results thus far suggest that the core-shells resemble the photoinduced dynamics of a standard film although the particles are dispersed in solution, which indicates the desired outcome of the work.

  16. SN 2011A: A Low-luminosity Interacting Transient with a Double Plateau and Strong Sodium Absorption

    Science.gov (United States)

    de Jaeger, T.; Anderson, J. P.; Pignata, G.; Hamuy, M.; Kankare, E.; Stritzinger, M. D.; Benetti, S.; Bufano, F.; Elias-Rosa, N.; Folatelli, G.; Förster, F.; González-Gaitán, S.; Gutiérrez, C. P.; Inserra, C.; Kotak, R.; Lira, P.; Morrell, N.; Taddia, F.; Tomasella, L.

    2015-07-01

    We present optical photometry and spectroscopy of the optical transient SN 2011A. Our data span 140 days after discovery including {BVRI} u\\prime g\\prime r\\prime i\\prime z\\prime photometry and 11 epochs of optical spectroscopy. Originally classified as a type IIn supernova (SN IIn) due to the presence of narrow Hα emission, this object shows exceptional characteristics. First, the light curve shows a double plateau, a property only observed before in the impostor SN 1997bs. Second, SN 2011A has a very low luminosity ({M}V=-15.72), placing it between normal luminous SNe IIn and SN impostors. Third, SN 2011A shows low velocity and high equivalent width absorption close to the sodium doublet, which increases with time and is most likely of circumstellar origin. This evolution is also accompanied by a change in line profile; when the absorption becomes stronger, a P Cygni profile appears. We discuss SN 2011A in the context of interacting SNe IIn and SN impostors, which appears to confirm the uniqueness of this transient. While we favor an impostor origin for SN 2011A, we highlight the difficulty in differentiating between terminal and non-terminal interacting transients. This paper includes data obtained with the 6.5 m Magellan Telescopes and du Pont telescope; the Gemini-North Telescope, Mauna Kea, USA (Gemini Program GN-2010B-Q67, PI: Stritzinger); the PROMPT telescopes at Cerro Tololo Inter-American Observatory in Chile; with the Liverpool Telescope operated on the island of La Palma by Liverpool John Moores University in the Spanish Observatorio del Roque de los Muchachos of the Instituto de Astrofisica de Canarias with financial support from the UK Science and Technology Facilities Council; based on observations made with the Nordic Optical Telescope, operated by the Nordic Optical Telescope Scientific Association at the Observatorio del Roque de los Muchachos, La Palma, Spain, of the Instituto de Astrofisica de Canarias; the NTT from ESO Science Archive

  17. Ultrafast Transient Absorption Spectroscopy Investigation of Photoinduced Dynamics in POLY(3-HEXYLTHIOPHENE)-BLOCK-OLIGO(ANTHRACENE-9,10-DIYL)

    Science.gov (United States)

    Strain, Jacob; Rathnayake, Hemali; Liu, Jinjun

    2017-06-01

    Semiconducting polymer nanostructures featuring bulk heterojunction (BHJ) architecture are promising light harvesters in photovoltaic (PV) devices because they allow control of individual domain sizes, internal structure and ordering, as well as well-defined contact between the electron donor and acceptor. Power conversion efficiency (PCE) of PV devices strongly depends on photoinduced dynamics. Understanding and optimizing photoinduced charge transfer processes in BHJ's hence help improve the performance of PV devices and increase their PCE in particular. We have investigated the photoinduced dynamics of a block polymer containing moieties of poly-3-hexylthiophene (P3HT) and polyanthracene (PANT) in solution and in solid state with femtosecond transient absorption (TA) spectroscopy. The dynamics of the polymer PANT alone are also studied as a control. The TA spectra of PANT includes a strong excited state absorption centered at 610 (nm) along with a stimulated emission signal stretching past the detection limit into the UV region which is absent in the monomer's spectra in the detection window. The block polymer's TA spectra strongly resembles that of P3HT but a noticeable positive pull on P3HT's stimulated emission signal residing at 575-620 (nm) is indicative of the excited state absorption of PANT in the adjacent spectral region. The doubling of the lifetime exciton delocalization on the block polymer versus P3HT alone have alluded that the lifetime of P3HT is extended by the covalent addition of PANT. The current spectroscopic investigation represents an interesting example of photoinduced processes in systems with complex energy level structure. Studies of dependence of change generation and separation on composition, dimension, and morphology of the heterojunctions are in process.

  18. Ultrafast Time-Resolved Emission and Absorption Spectra of meso-Pyridyl Porphyrins upon Soret Band Excitation Studied by Fluorescence Up-Conversion and Transient Absorption Spectroscopy.

    Science.gov (United States)

    Venkatesh, Yeduru; Venkatesan, M; Ramakrishna, B; Bangal, Prakriti Ranjan

    2016-09-08

    A comprehensive study of ultrafast molecular relaxation processes of isomeric meso-(pyridyl) porphyrins (TpyPs) has been carried out by using femtosecond time-resolved emission and absorption spectroscopic techniques upon pumping at 400 nm, Soret band (B band or S2), in 4:1 dichloromethane (DCM) and tetrahydrofuran (THF) solvent mixture. By combined studies of fluorescence up-conversion, time-correlated single photon counting, and transient absorption spectroscopic techniques, a complete model with different microscopic rate constants associated with elementary processes involved in electronic manifolds has been reported. Besides, a distinct coherent nuclear wave packet motion in Qy state is observed at low-frequency mode, ca. 26 cm(-1) region. Fluorescence up-conversion studies constitute ultrafast time-resolved emission spectra (TRES) over the whole emission range (430-710 nm) starting from S2 state to Qx state via Qy state. Careful analysis of time profiles of up-converted signals at different emission wavelengths helps to reveal detail molecular dynamics. The observed lifetimes are as indicated: A very fast decay component with 80 ± 20 fs observed at ∼435 nm is assigned to the lifetime of S2 (B) state, whereas being a rise component in the region of between 550 and 710 nm emission wavelength pertaining to Qy and Qx states, it is attributed to very fast internal conversion (IC) occurring from B → Qy and B → Qx as well. Two distinct components of Qy emission decay with ∼200-300 fs and ∼1-1.5 ps time constants are due to intramolecular vibrational redistribution (IVR) induced by solute-solvent inelastic collisions and vibrational redistribution induced by solute-solvent elastic collision, respectively. The weighted average of these two decay components is assigned as the characteristic lifetime of Qy, and it ranges between 0.3 and 0.5 ps. An additional ∼20 ± 2 ps rise component is observed in Qx emission, and it is assigned to the formation time of

  19. A new approach for the determination of sulphur in food samples by high-resolution continuum source flame atomic absorption spectrometer.

    Science.gov (United States)

    Ozbek, N; Baysal, A

    2015-02-01

    The new approach for the determination of sulphur in foods was developed, and the sulphur concentrations of various fresh and dried food samples determined using a high-resolution continuum source flame atomic absorption spectrometer with an air/acetylene flame. The proposed method was optimised and the validated using standard reference materials, and certified values were found to be within the 95% confidence interval. The sulphur content of foods ranged from less than the LOD to 1.5mgg(-1). The method is accurate, fast, simple and sensitive. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Transient-Absorption Spectroscopy of Cis-Trans Isomerization of N,N-dimethyl-4,4'-Azodianiline with 3D-Printed Temperature-Controlled Sample Holder

    Science.gov (United States)

    Kosenkov, Dmytro; Shaw, James; Zuczek, Jennifer; Kholod, Yana

    2016-01-01

    The laboratory unit demonstrates a project based approach to teaching physical chemistry laboratory where upper-division undergraduates carry out a transient-absorption experiment investigating the kinetics of cis-trans isomerization of N,N-dimethyl-4,4'-azodianiline. Students participate in modification of a standard flash-photolysis spectrometer…

  1. Non-Destructive and Discriminating Identification of Illegal Drugs by Transient Absorption Spectroscopy in the Visible and Near-IR Wavelength Range

    Science.gov (United States)

    Sato, Chie; Furube, Akihiro; Katoh, Ryuzi; Nonaka, Hidehiko; Inoue, Hiroyuki

    2008-11-01

    We have tested the possibility of identifying illegal drugs by means of nanosecond transient absorption spectroscopy with a 10-ns UV-laser pulse for the excitation light and visible-to-near-IR light for the probe light. We measured the transient absorption spectra of acetonitrile solutions of d-methamphetamine, dl-3,4-methylenedioxymethamphetamine hydrochloride (MDMA), and dl-N-methyl-1-(1,3-benzodioxol-5-yl)-2-butanamine hydrochloride (MBDB), which are illegal drugs widely consumed in Japan. Transient absorption signals of these drugs were observed between 400 and 950 nm, a range in which they are transparent in the ground state. By analyzing the spectra in terms of exponential and Gaussian functions, we could identify the drugs and discriminate them from chemical substances having similar structures. We propose that transient absorption spectroscopy will be a useful, non-destructive method of inspecting for illegal drugs, especially when they are dissolved in liquids. Such a method may even be used for drugs packed in opaque materials if it is further extended to utilize intense femtosecond laser pulses.

  2. Direct determination of total sulfur in wine using a continuum-source atomic-absorption spectrometer and an air-acetylene flame.

    Science.gov (United States)

    Huang, Mao Dong; Becker-Ross, Helmut; Florek, Stefan; Heitmann, Uwe; Okruss, Michael

    2005-08-01

    Determination of sulfur in wine is an important analytical task, particularly with regard to food safety legislation, wine trade, and oenology. Hitherto existing methods for sulfur determination all have specific drawbacks, for example high cost and time consumption, poor precision or selectivity, or matrix effects. In this paper a new method, with low running costs, is introduced for direct, reliable, rapid, and accurate determination of the total sulfur content of wine samples. The method is based on measurement of the molecular absorption of carbon monosulfide (CS) in an ordinary air-acetylene flame by using a high-resolution continuum-source atomic-absorption spectrometer including a novel high-intensity short-arc xenon lamp. First results for total sulfur concentrations in different wine samples were compared with data from comparative ICP-MS measurements. Very good agreement within a few percent was obtained.

  3. Femtosecond transient absorption spectroscopy study of the early events of norfloxacin in aqueous solutions with varying pH values.

    Science.gov (United States)

    Su, Tao; Li, Ming-De; Ma, Jiani; Wong, Naikei; Phillips, David Lee

    2014-11-26

    The photophysics and photochemistry of norfloxacin (NF) have been investigated in aqueous solutions of different pH using femtosecond transient absorption spectroscopy (fs-TA). Resonance Raman spectroscopic experiments on NF have also been conducted in aqueous solutions of different pH to characterize the vibrational and structural information on the initial forms of NF. The experimental results in combination with density functional theory calculations of the key intermediates help us to elucidate the early events for NF after photoexcitation in aqueous solutions with varying pH values. The fs-TA results indicate that NF mainly underwent photophysical processes on the early delay time scale (before 3 ns), and no photochemical reactions occurred on this time scale. Specifically, after the irradiation of NF, the molecule reaches a higher excited singlet Sn and then decays to the lowest-lying excited singlet state S1 followed by intersystem crossing to transform into the lowest-lying triplet state T1 with a high efficiency, with an exception that there is a lower efficiency observed in basic aqueous solution due to the generation of an intramolecular electron transfer as an additional pathway to waste energy.

  4. A Combination of Chemometrics and Quantum Mechanics Methods Applied to Analysis of Femtosecond Transient Absorption Spectrum of Ortho-Nitroaniline

    Science.gov (United States)

    Yi, Jing; Xiong, Ying; Cheng, Kemei; Li, Menglong; Chu, Genbai; Pu, Xuemei; Xu, Tao

    2016-01-01

    A combination of the advanced chemometrics method with quantum mechanics calculation was for the first time applied to explore a facile yet efficient analysis strategy to thoroughly resolve femtosecond transient absorption spectroscopy of ortho-nitroaniline (ONA), served as a model compound of important nitroaromatics and explosives. The result revealed that the ONA molecule is primarily excited to S3 excited state from the ground state and then ultrafast relaxes to S2 state. The internal conversion from S2 to S1 occurs within 0.9 ps. One intermediate state S* was identified in the intersystem crossing (ISC) process, which is different from the specific upper triplet receiver state proposed in some other nitroaromatics systems. The S1 state decays to the S* one within 6.4 ps and then intersystem crossing to the lowest triplet state within 19.6 ps. T1 was estimated to have a lifetime up to 2 ns. The relatively long S* state and very long-lived T1 one should play a vital role as precursors to various nitroaromatic and explosive photoproducts.

  5. A Combination of Chemometrics and Quantum Mechanics Methods Applied to Analysis of Femtosecond Transient Absorption Spectrum of Ortho-Nitroaniline

    Science.gov (United States)

    Yi, Jing; Xiong, Ying; Cheng, Kemei; Li, Menglong; Chu, Genbai; Pu, Xuemei; Xu, Tao

    2016-01-01

    A combination of the advanced chemometrics method with quantum mechanics calculation was for the first time applied to explore a facile yet efficient analysis strategy to thoroughly resolve femtosecond transient absorption spectroscopy of ortho-nitroaniline (ONA), served as a model compound of important nitroaromatics and explosives. The result revealed that the ONA molecule is primarily excited to S3 excited state from the ground state and then ultrafast relaxes to S2 state. The internal conversion from S2 to S1 occurs within 0.9 ps. One intermediate state S* was identified in the intersystem crossing (ISC) process, which is different from the specific upper triplet receiver state proposed in some other nitroaromatics systems. The S1 state decays to the S* one within 6.4 ps and then intersystem crossing to the lowest triplet state within 19.6 ps. T1 was estimated to have a lifetime up to 2 ns. The relatively long S* state and very long-lived T1 one should play a vital role as precursors to various nitroaromatic and explosive photoproducts. PMID:26781083

  6. Transient absorption spectroscopy in biology using the Super-ACO storage ring FEL and the synchrotron radiation combination

    CERN Document Server

    Renault, E; De Ninno, G; Garzella, D; Hirsch, M; Nahon, L; Nutarelli, D

    2001-01-01

    The Super-ACO storage ring FEL, covering the UV range down to 300 nm with a high average power (300 mW at 350 nm) together with a high stability and long lifetime, is a unique tool for the performance of users applications. We present here the first pump-probe two color experiments on biological species using a storage ring FEL coupled to the synchrotron radiation. The intense UV pulse of the Super-ACO FEL is used to prepare a high initial concentration of chromophores in their first singlet electronic excited state. The nearby bending magnet synchrotron radiation provides, on the other hand a pulsed, white light continuum (UV-IR), naturally synchronized with the FEL pulses and used to probe the photochemical subsequent events and the associated transient species. We have demonstrated the feasibility with a dye molecule (POPOP) observing a two-color effect, signature of excited state absorption and a temporal signature with Acridine. Applications on various chromophores of biological interest are carried out,...

  7. Ultrafast Carrier Trapping of a Metal-Doped Titanium Dioxide Semiconductor Revealed by Femtosecond Transient Absorption Spectroscopy

    KAUST Repository

    Sun, Jingya

    2014-06-11

    We explored for the first time the ultrafast carrier trapping of a metal-doped titanium dioxide (TiO2) semiconductor using broad-band transient absorption (TA) spectroscopy with 120 fs temporal resolution. Titanium dioxide was successfully doped layer-by-layer with two metal ions, namely tungsten and cobalt. The time-resolved data demonstrate clearly that the carrier trapping time decreases progressively as the doping concentration increases. A global-fitting procedure for the carrier trapping suggests the appearance of two time components: a fast one that is directly associated with carrier trapping to the defect state in the vicinity of the conduction band and a slow one that is attributed to carrier trapping to the deep-level state from the conduction band. With a relatively long doping deposition time on the order of 30 s, a carrier lifetime of about 1 ps is obtained. To confirm that the measured ultrafast carrier dynamics are associated with electron trapping by metal doping, we explored the carrier dynamics of undoped TiO2. The findings reported here may be useful for the implementation of high-speed optoelectronic applications and fast switching devices.

  8. Probing autoionizing states of molecular oxygen with XUV transient absorption: Electronic-symmetry-dependent line shapes and laser-induced modifications

    Science.gov (United States)

    Liao, Chen-Ting; Li, Xuan; Haxton, Daniel J.; Rescigno, Thomas N.; Lucchese, Robert R.; McCurdy, C. William; Sandhu, Arvinder

    2017-04-01

    We used extreme ultraviolet (XUV) transient absorption spectroscopy to study the autoionizing Rydberg states of oxygen in an electronically- and vibrationally-resolved fashion. XUV pulse initiates molecular polarization and near-infrared pulse perturbs its evolution. Transient absorption spectra show positive optical-density (OD) change in the case of n s σg and n d πg autoionizing states of oxygen and negative OD change for n d σg states. Multiconfiguration time-dependent Hartree-Fock (MCTDHF) calculations are used to simulate the transient absorption and the resulting spectra and temporal evolution agree with experimental observations. We model the effect of near-infrared perturbation on molecular polarization and find that the laser-induced phase-shift model agrees with the experimental and MCTDHF results, while the laser-induced attenuation model does not. We relate the electronic-state-symmetry-dependent sign of the OD change to the Fano parameters of the static absorption line shapes.

  9. Application of Internal Standard Method for Several 3d-Transition Metallic Elements in Flame Atomic Absorption Spectrometry Using a Multi-wavelength High-resolution Spectrometer.

    Science.gov (United States)

    Toya, Yusuke; Itagaki, Toshiko; Wagatsuma, Kazuaki

    2017-01-01

    We investigated a simultaneous internal standard method in flame atomic absorption spectrometry (FAAS), in order to better the analytical precision of 3d-transition metals contained in steel materials. For this purpose, a new spectrometer system for FAAS, comprising a bright xenon lamp as the primary radiation source and a high-resolution Echelle monochromator, was employed to measure several absorption lines at a wavelength width of ca. 0.3 nm at the same time, which enables the absorbances of an analytical line and also an internal standard line to be estimated. In considering several criteria for selecting an internal standard element and the absorption line, it could be suggested that platinum-group elements: ruthenium, rhodium, or palladium, were suitable for an internal standard element to determine the 3d-transition metal elements, such as titanium, iron, and nickel, by measuring an appropriate pair of these absorption lines simultaneously. Several variances of the absorption signal, such as a variation in aspirated amounts of sample solution and a short-period drift of the primary light source, would be corrected and thus reduced, when the absorbance ratio of the analytical line to the internal standard line was measured. In Ti-Pd, Ni-Rh, and Fe-Ru systems chosen as typical test samples, the repeatability of the signal respnses was investigated with/without the internal standard method, resulting in better precision when the internal standard method was applied in the FAAS with a nitrous oxide-acetylene flame rather than an air-acetylene flame.

  10. Qualification of a Multi-Channel Infrared Laser Absorption Spectrometer for Monitoring CO, HCl, HCN, HF, and CO2 Aboard Manned Spacecraft

    Science.gov (United States)

    Briggs, Ryan M.; Frez, Clifford; Forouhar, Siamak; May, Randy D.; Meyer, Marit E.; Kulis, Michael J.; Berger, Gordon M.

    2015-01-01

    Monitoring of specific combustion products can provide early-warning detection of accidental fires aboard manned spacecraft and also identify the source and severity of combustion events. Furthermore, quantitative in situ measurements are important for gauging levels of exposure to hazardous gases, particularly on long-duration missions where analysis of returned samples becomes impractical. Absorption spectroscopy using tunable laser sources in the 2 to 5 micrometer wavelength range enables accurate, unambiguous detection of CO, HCl, HCN, HF, and CO2, which are produced in varying amounts through the heating of electrical components and packaging materials commonly used aboard spacecraft. Here, we report on calibration and testing of a five-channel laser absorption spectrometer designed to accurately monitor ambient gas-phase concentrations of these five compounds, with low-level detection limits based on the Spacecraft Maximum Allowable Concentrations. The instrument employs a two-pass absorption cell with a total optical pathlength of 50 cm and a dedicated infrared semiconductor laser source for each target gas. We present results from testing the five-channel sensor in the presence of trace concentrations of the target compounds that were introduced using both gas sources and oxidative pyrolysis (non-flaming combustion) of solid material mixtures.

  11. Electron and hadron separation by the system consisting of active converter, scintillation counter and total absorption spectrometer

    International Nuclear Information System (INIS)

    Astvatsaturov, R.G.; Arkhipov, V.V.; Vasil'ev, S.E.

    1988-01-01

    Hadron suppression is investigated, using 2 GeV/c momentum π - -meson beam, which contains 6% electrons, by means of detection system, including lead glass active counter, lead glass Cherenkov γ-spectrometers, 1 m length scintillation counter scanned by two photomultipliers from the ends. Selection of events by means of scintillation counter has allowed to reduce hadron contribution by one order at ≥ 90% efficiency of electron detection. Accuracy of determination of electromagnetic shower axis coordinate by time difference of light signal propagation in scintillation converter practically does not depend on converter thickness within 2-6 rad. un. thickness range and equals to 2.1 cm

  12. Probing the Impact of Solvation on Photoexcited Spin Crossover Complexes with High-Precision X-ray Transient Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Cunming; Zhang, Jianxin [State; Lawson Daku, Latévi M. [Département; Gosztola, David; Canton, Sophie E. [ELI-ALPS, ELI-HU Non-Profit Ltd., Dugonics ter 13, Szeged 6720, Hungary; Attosecond; Zhang, Xiaoyi

    2017-11-17

    Investigating the photoinduced electronic and structural response of bistable molecular building blocks incorporating transition metals in solution phase constitutes a necessary stepping stone for steering their properties towards applications and perfomance optimizations. This work presents a detailed X-ray transient absorption (XTA) spectroscopy study of a prototypical spin crossover (SCO) complex [FeII(mbpy)3]2+ (where mbpy=4,4’-dimethyl-2,2’-bipyridine) with a [FeIIN6] first coordination shell in water (H2O) and acetonitrile (CH3CN). The unprecedented data quality of the XTA spectra together with the direct fitting of the difference spectra in k space using a large number of scattering paths enables resolving the subtle difference in the photoexcited structures of an FeII complex in two solvents for the first time. Compared to the low spin (LS) 1A1 state, the average Fe-N bond elongations for the photoinduced high spin (HS) 5T2 state are found to be 0.181 . 0.003 Å in H2O and 0.199 . 0.003 Å in CH3CN. This difference in structural response is attributed to ligand-solvent interactions that are stronger in H2O than in CH3CN for the HS excited state. Our studies demonstrate that, although the metal center of [FeII(mbpy)3]2+ could have been expected to be rather shielded by the three bidentate ligands with quasi-octahedral-coordination, the ligand field strength in the HS excited state is nevertheless indirectly affected by solvation that modifies the charge distribution within the Fe-N covalent bonds. More generally, this work highlights the importance of including solvation effects in order to develop a generalized understanding of the spin-state switching at the atomic level.

  13. Photoinduced electron transfer between 2-methylanthraquinone and triethylamine in an ionic liquid: Time-resolved EPR and transient absorption spectroscopy study

    Science.gov (United States)

    Zhu, Guanglai; Wang, Yu; Fu, Haiying; Xu, Xinsheng; Cui, Zhifeng; Ji, Xuehan; Wu, Guozhong

    2015-02-01

    Photoinduced electron transfer between 2-methylanthraquinone (MeAQ) and triethylamine (TEA) in a room-temperature ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim][PF6]), was investigated by comparing the time-resolved electron paramagnetic resonance (TR-EPR) spectroscopy and the transient absorption spectroscopy. The results of TR-EPR spectroscopy, in which MeAQ was 8 mmol L-1 and TEA was 150 mmol L-1, indicated that the transient radical would exist longer time in [bmim][PF6] than in acetonitrile. At the delay time of 8 μs after laser excitation, the TR-EPR signal transformed from an emissive peak into an absorptive peak when the experiment was performed in [bmim][PF6]. The results of the transient absorption spectroscopy, in which MeAQ was 0.1 mmol L-1 and TEA was 2.2 mmol L-1, showed that the efficiency and the rate of the photoinduced electron transfer reaction in [bmim][PF6] were obviously lower than that in acetonitrile. It was concluded that various factors, such as concentration, viscosity and local structural transformation of the solution, have an influence on the process of photoinduced electron transfer in [bmim][PF6].

  14. Determination of copper and iron in the human aqueous humor by atomic absorption spectrometer with graphite furnace

    International Nuclear Information System (INIS)

    Iqbal, Z.; Mohammad, Z.; Shah, M.T.; Saeed, M.; Imdadullah

    1999-01-01

    The concentration of copper and iron was determined in human aqueous humor using atomic absorption spectrophotometer equipped with graphite furnace. The mean (+- SEM) concentrations of copper (n=16) and iron (n=14) were 0.0234 -+ 0.0045 mu g.ml/sup -1/ and 0.045 -+ 0.0092 mu.ml/sup -1/ respectively. In male and female, the concentrations of copper (p< 0.82) and iron (p<0.38) were not significantly different. (author)

  15. UV/VIS SPECTROMETER DETERMINATION OF CAFFEINE IN GREEN COFFEE BEANS FROM HARARGHE, ETHIOPIA, USING BEER-LAMBERT’S LAW AND INTEGRATED ABSORPTION COEFFICIENT TECHNIQUES

    Directory of Open Access Journals (Sweden)

    EPHREM G. DEMISSIE

    2016-07-01

    Full Text Available A total of fifteen samples of green coffee (Coffea arabica L. beans from the major producing region of Hararghe Ethiopia were studied using UV-Vis spectrometer measurement caffeine quantitative analysis from coffee beans. The number density of caffeine in green coffee beans has been reported using Beer-Lambert’s law and integrating absorption coefficient technique. Our results obtained using integrated absorption and Beer-Lambert’s law has a good agreement and we observed a maximum difference of 10.4 %. Based on their low caffeine concentrations among the samples collected were found in Jarso coffee. Coffee beans from the Harar Aboker were characterized by higher concentrations of caffeine. The determined concentration for caffeine in coffee beans (% w/w ranged 0.601 % to 0.903 %. The concentrations of the caffeine varied significantly, depending on the geographical origin of the beans. The concentrations of caffeine in coffee collected from in Hararghe region were noticeably lower than their counterpart (1.0 - 1.2 % grows in the other parts of Ethiopia.

  16. Studies of electron-hole recombination processes at deep levels in GaAs and GaP by means of transient optical absorption spectroscopy

    International Nuclear Information System (INIS)

    Sugiyama, T.; Ishikawa, Y.; Tanimura, K.; Hayashi, Y.; Itoh, N.

    1989-01-01

    Studies of recombination processes by means of transient optical absorption (TOA) spectroscopy in GaAs and GaP are reviewed. It is pointed out that the technique can reveal production of excited states having long lifetimes and of non-luminescent metastable states. Two distinct recombination processes in GaAs containing EL2 defects are discussed: one is at the metastable EL2 defects, accompanied with transformation to the EL2 defects and the other is at deep acceptors through pair recombination. (author) 11 refs., 2 figs

  17. Quantum state-resolved probing of strong-field-ionized xenon atoms using femtosecond high-order harmonic transient absorption spectroscopy.

    Science.gov (United States)

    Loh, Zhi-Heng; Khalil, Munira; Correa, Raoul E; Santra, Robin; Buth, Christian; Leone, Stephen R

    2007-04-06

    Femtosecond high-order harmonic transient absorption spectroscopy is used to resolve the complete |j,m quantum state distribution of Xe+ produced by optical strong-field ionization of Xe atoms at 800 nm. Probing at the Xe N4/5 edge yields a population distribution rhoj,|m| of rho3/2,1/2ratiorho1/2,1/2ratiorho3/2,3/2=75+/-6 :12+/-3 :13+/-6%. The result is compared to a tunnel ionization calculation with the inclusion of spin-orbit coupling, revealing nonadiabatic ionization behavior. The sub-50-fs time resolution paves the way for tabletop extreme ultraviolet absorption probing of ultrafast dynamics.

  18. Effects of excited state mixing on transient absorption spectra in dimers Application to photosynthetic light-harvesting complex II

    CERN Document Server

    Valkunas, L; Trinkunas, G; Müller, M G; Holzwarth, A R

    1999-01-01

    The excited state mixing effect is taken into account considering the difference spectra of dimers. Both the degenerate (homo) dimer as well as the nondegenerate (hetero) dimer are considered. Due to the higher excited state mixing with the two-exciton states in the homodimer, the excited state absorption (or the difference spectrum) can be strongly affected in comparison with the results obtained in the Heitler-London approximation. The difference spectrum of the heterodimer is influenced by two resonance effects (i) mixing of the ground state optical transitions of both monomers in the dimer and (ii) mixing of the excited state absorption of the excited monomer with the ground state optical transition in the nonexcited monomer. These effects have been tested by simulating the difference absorption spectra of the light-harvesting complex of photosystem II (LHC II) experimentally obtained with the 60 fs excitation pulses at zero delay times and various excitation wavelengths. The pairs of coupled chlorophylls...

  19. Global sampling of the photochemical reaction paths of bromoform by ultrafast deep-UV through near-IR transient absorption and ab initio multiconfigurational calculations.

    Science.gov (United States)

    Pal, S K; Mereshchenko, A S; Butaeva, E V; El-Khoury, P Z; Tarnovsky, A N

    2013-03-28

    Ultrafast deep-ultraviolet through near infrared (210-950 nm) transient absorption spectroscopy complemented by ab initio multiconfigurational calculations offers a global description of the photochemical reaction pathways of bromoform following 255-nm excitation in methylcyclohexane and acetonitrile solutions. Photoexcitation of CHBr3 leads to the ground-state iso-CHBr3 product in a large quantum yield (∼35%), formed through two different mechanisms: concerted excited-state isomerization and cage-induced isomerization through the recombination of the nascent radical pair. These two processes take place on different time scales of tens of femtoseconds and several picoseconds, respectively. The novel ultrafast direct isomerization pathway proposed herein is consistent with the occurrence of a conical intersection between the first excited singlet state of CHBr3 and the ground electronic state of iso-CHBr3. Complete active space self-consistent field calculations characterize this singularity in the vicinity of a second order saddle point on the ground state which connects the two isomer forms. For cage-induced isomerization, both the formation of the nascent radical pair and its subsequent collapse into ground-state iso-CHBr3 are directly monitored through the deep-ultraviolet absorption signatures of the radical species. In both mechanisms, the optically active (i.e., those with largest Franck-Condon factors) C-Br-Br bending and Br-Br stretching modes of ground-state iso-CHBr3 have the largest projection on the reaction coordinate, enabling us to trace the structural changes accompanying vibrational relaxation of the non-equilibrated isomers through transient absorption dynamics. The iso-CHBr3 photoproduct is stable in methylcyclohexane, but undergoes either facile thermal isomerization to the parent CHBr3 structure through a cyclic transition state stabilized by the polar acetonitrile medium (∼300-ps lifetime), and hydrolysis in the presence of water.

  20. Vegetation species composition and canopy architecture information expressed in leaf water absorption measured in the 1000 nm and 2200 spectral region by an imaging spectrometer

    Science.gov (United States)

    Green, Robert O.; Roberts, Dar A.

    1995-01-01

    Plant species composition and plant architectural attributes are critical parameters required for the measuring, monitoring, and modeling of terrestrial ecosystems. Remote sensing is commonly cited as an important tool for deriving vegetation properties at an appropriate scale for ecosystem studies, ranging from local to regional and even synoptic scales. Classical approaches rely on vegetation indices such as the normalized difference vegetation index (NDVI) to estimate biophysical parameters such as leaf area index or intercepted photosynthetically active radiation (IPAR). Another approach is to apply a variety of classification schemes to map vegetation and thus extrapolate fine-scale information about specific sites to larger areas of similar composition. Imaging spectrometry provides additional information that is not obtainable through broad-band sensors and that may provide improved inputs both to direct biophysical estimates as well as classification schemes. Some of this capability has been demonstrated through improved discrimination of vegetation, estimates of canopy biochemistry, and liquid water estimates from vegetation. We investigate further the potential of leaf water absorption estimated from Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data as a means for discriminating vegetation types and deriving canopy architectural information. We expand our analysis to incorporate liquid water estimates from two spectral regions, the 1000-nm region and the 2200-nm region. The study was conducted in the vicinity of Jasper Ridge, California, which is located on the San Francisco peninsula to the west of the Stanford University campus. AVIRIS data were acquired over Jasper Ridge, CA, on June 2, 1992, at 19:31 UTC. Spectra from three sites in this image were analyzed. These data are from an area of healthy grass, oak woodland, and redwood forest, respectively. For these analyses, the AVIRIS-measured upwelling radiance spectra for the entire Jasper

  1. Tailored pump-probe transient spectroscopy with time-dependent density-functional theory: controlling absorption spectra

    Science.gov (United States)

    Walkenhorst, Jessica; De Giovannini, Umberto; Castro, Alberto; Rubio, Angel

    2016-05-01

    Recent advances in laser technology allow us to follow electronic motion at its natural time-scale with ultra-fast time resolution, leading the way towards attosecond physics experiments of extreme precision. In this work, we assess the use of tailored pumps in order to enhance (or reduce) some given features of the probe absorption (for example, absorption in the visible range of otherwise transparent samples). This type of manipulation of the system response could be helpful for its full characterization, since it would allow us to visualize transitions that are dark when using unshaped pulses. In order to investigate these possibilities, we perform first a theoretical analysis of the non-equilibrium response function in this context, aided by one simple numerical model of the hydrogen atom. Then, we proceed to investigate the feasibility of using time-dependent density-functional theory as a means to implement, theoretically, this absorption-optimization idea, for more complex atoms or molecules. We conclude that the proposed idea could in principle be brought to the laboratory: tailored pump pulses can excite systems into light-absorbing states. However, we also highlight the severe numerical and theoretical difficulties posed by the problem: large-scale non-equilibrium quantum dynamics are cumbersome, even with TDDFT, and the shortcomings of state-of-the-art TDDFT functionals may still be serious for these out-of-equilibrium situations.

  2. Heat of vaporization spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, D. Jr.

    1979-03-01

    Multilayer desorption measurements of various substances adsorbed on a stainless-steel substrate are found to exhibit desorption profiles consistent with a zeroth-order desorption model. The singleness of the desorption transients together with their narrow peak widths makes the technique ideally suited for a heat of vaporization spectrometer for either substance analysis or identification.

  3. Heat of vaporization spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, D. Jr.

    1978-01-01

    Multilayer desorption measurements of various substances adsorbed on a stainless steel substrate are found to exhibit desorption profiles consistent with a zeroth order desorption model. The singleness of the desorption transients together with their narrow peak widths makes the technique ideally suited for a heat of vaporization spectrometer for either substance analysis or identification.

  4. Triplet excited electronic state switching induced by hydrogen bonding: A transient absorption spectroscopy and time-dependent DFT study

    Energy Technology Data Exchange (ETDEWEB)

    Ravi Kumar, Venkatraman; Ariese, Freek; Umapathy, Siva, E-mail: umapathy@ipc.iisc.ernet.in [Inorganic and Physical Chemistry Department, Indian Institute of Science, Bangalore 560012 (India)

    2016-03-21

    The solvent plays a decisive role in the photochemistry and photophysics of aromatic ketones. Xanthone (XT) is one such aromatic ketone and its triplet-triplet (T-T) absorption spectra show intriguing solvatochromic behavior. Also, the reactivity of XT towards H-atom abstraction shows an unprecedented decrease in protic solvents relative to aprotic solvents. Therefore, a comprehensive solvatochromic analysis of the triplet-triplet absorption spectra of XT was carried out in conjunction with time dependent density functional theory using the ad hoc explicit solvent model approach. A detailed solvatochromic analysis of the T-T absorption bands of XT suggests that the hydrogen bonding interactions are different in the corresponding triplet excited states. Furthermore, the contributions of non-specific and hydrogen bonding interactions towards differential solvation of the triplet states in protic solvents were found to be of equal magnitude. The frontier molecular orbital and electron density difference analysis of the T{sub 1} and T{sub 2} states of XT indicates that the charge redistribution in these states leads to intermolecular hydrogen bond strengthening and weakening, respectively, relative to the S{sub 0} state. This is further supported by the vertical excitation energy calculations of the XT-methanol supra-molecular complex. The intermolecular hydrogen bonding potential energy curves obtained for this complex in the S{sub 0}, T{sub 1}, and T{sub 2} states support the model. In summary, we propose that the different hydrogen bonding mechanisms exhibited by the two lowest triplet excited states of XT result in a decreasing role of the nπ{sup ∗} triplet state, and are thus responsible for its reduced reactivity towards H-atom abstraction in protic solvents.

  5. Tracking Co(I) Intermediate in operando in Photocatalytic Hydrogen Evolution by X-ray transient Absorption Spectroscopy and DFT Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhi-Jun; Zhan, Fei; Xiao, Hongyan; Zhang, Xiaoyi; Kong, Qing-Yu; Fan, Xiang-Bing; Liu, Wen-Qiang; Huang, Mao-Yong; Huang, Cheng; Gao, Yu-Ji; Li, Xu-Bing; Meng, Qing-Yuan; Feng, Ke; Chen, Bin; Tung, Chen-Ho; Zhao, Hai-Feng; Tao, Ye; Wu, Li-Zhu

    2016-12-07

    X-ray transient absorption spectroscopy (XTA) and optical transient spectroscopy (OTA) were used to probe the Co(I) intermediate generated in situ from an aqueous photocatalytic hydrogen evolution system, with [RuII(bpy)3]Cl2·6H2O as the photosensitizer, ascorbic acid/ascorbate as the electron donor, and the Co-polypyridyl complex ([CoII(DPABpy) Cl]Cl) as the pre-catalyst. Upon exposure to light, the XTA measured at Co K-edge visualizes the grow and decay of the Co(I) intermediate, and reveals its Co-N bond contraction of 0.09 ± 0.03 Å. Density functional theory (DFT) calculations support the bond contraction and illustrate that the metal-to-ligand π back-bonding greatly stabilizes the penta-coordinated Co(I) intermediate, which provides easy photon access. To the best of our knowledge, this is the first example of capturing the penta-coordinated Co(I) intermediate in operando with bond contraction by XTA, thereby providing new insights for fundamental understanding of structure– function relationship of cobalt-based molecular catalysts.

  6. First-principles simulation of transient x-ray absorption spectroscopy of photo-excited molecular systems

    Science.gov (United States)

    Pemmaraju, Das; Closser, Kristina; Prendergast, David; Simes; Molecular Foundry Collaboration Collaboration

    We explore the utility of beyond-ground-state density functional methods such as constrained density functional theory (c-DFT) and time-dependent density functional theory (TDDFT) in the interpretation of time-resolved X-ray absorption spectroscopies investigating chemical dynamics in photo-excited molecular systems. Recent results based on a methodology that combines a state-by-state self-consistent field description such as c-DFT with a frequency domain linear-response TDDFT approach to model the core-level spectroscopy of photo-excited ring-opening dynamics in small molecular systems is discussed. Illustrative case studies involving the strong-field ionization of Selenophene and resonant UV-vis excitation of 1,3-cyclohexadiene are presented.

  7. Ligand-field symmetry effects in Fe(ii) polypyridyl compounds probed by transient X-ray absorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hana; Strader, Matthew L.; Hong, Kiryong; Jamula, Lindsey; Gullikson, Eric M.; Kim, Tae Kyu; de Groot, Frank M. F.; McCusker, James K.; Schoenlein, Robert W.; Huse, Nils

    2012-01-01

    Ultrafast excited-state evolution in polypyridyl FeII complexes are of fundamental interest for understanding the origins of the sub-ps spin-state changes that occur upon photoexcitation of this class of compounds as well as for the potential impact such ultrafast dynamics have on incorporation of these compounds in solar energy conversion schemes or switchable optical storage technologies. We have demonstrated that ground-state and, more importantly, ultrafast time-resolved x-ray absorption methods can offer unique insights into the interplay between electronic and geometric structure that underpin the photo-induced dynamics of this class of compounds. The present contribution examines in greater detail how the symmetry of the ligand field surrounding the metal ion can be probed using these x-ray techniques. In particular, we show that steady-state K-edge spectroscopy of the nearest-neighbour nitrogen atoms reveals the characteristic chemical environment of the respective ligands and suggests an interesting target for future charge-transfer femtosecond and attosecond spectroscopy in the x-ray water window.

  8. Core-level attosecond transient absorption spectroscopy of laser-dressed solid films of Si and Zr

    Science.gov (United States)

    Seres, Enikoe; Seres, Jozsef; Serrat, Carles; Namba, Shinichi

    2016-10-01

    We investigated experimentally as well as theoretically the ultrafast response of the wave function of the conduction band (CB) of Si and Zr to a near-infrared laser field using extreme ultraviolet (XUV) absorption spectroscopy in the spectral range of 80-220 eV. The measured dynamics of the XUV transmission demonstrates that the wave function of the CB follows the electric field of the dressing laser pulse. In these terms, laser dressing was earlier mainly studied on gases. Measurements with two-femtosecond and 200-attosecond temporal steps were performed in the vicinity of the Si L2 ,3 edge near 100 eV, the Si L1 edge near 150 eV, and the Zr M4 ,5 edge near 180 eV. The observed changes were dependent on the core states being excited by the XUV probe pulse. At the 2 p to CB transitions of Si, the XUV transmission increased via the effect of the dressing laser pulse, while at the 2 s to CB transition of Si and the 3 d to CB transition of Zr, the XUV transmission decreased. Furthermore, beats between the transition from 2 p1 /2 and 2 p3 /2 levels of Si and from 3 d3 /2 and 3 d5 /2 levels of Zr were observed with 20.7 fs and 3.6 fs periods.

  9. Monolithic spectrometer

    Science.gov (United States)

    Rajic, Slobodan; Egert, Charles M.; Kahl, William K.; Snyder, Jr., William B.; Evans, III, Boyd M.; Marlar, Troy A.; Cunningham, Joseph P.

    1998-01-01

    A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays.

  10. On the participation of photoinduced N-H bond fission in aqueous adenine at 266 and 220 nm: a combined ultrafast transient electronic and vibrational absorption spectroscopy study.

    Science.gov (United States)

    Roberts, Gareth M; Marroux, Hugo J B; Grubb, Michael P; Ashfold, Michael N R; Orr-Ewing, Andrew J

    2014-11-26

    A combination of ultrafast transient electronic absorption spectroscopy (TEAS) and transient vibrational absorption spectroscopy (TVAS) is used to investigate whether photoinduced N–H bond fission, mediated by a dissociative 1πσ(*) state, is active in aqueous adenine (Ade) at 266 and 220 nm. In order to isolate UV/visible and IR spectral signatures of the adeninyl radical (Ade[-H]), formed as a result of N–H bond fission, TEAS and TVAS are performed on Ade in D2O under basic conditions (pD = 12.5), which forms Ade[-H](-) anions via deprotonation at the N7 or N9 sites of Ade's 7H and 9H tautomers. At 220 nm we observe one-photon detachment of an electron from Ade[-H](-), which generates solvated electrons (eaq(-)) together with Ade[-H] radicals, with clear signatures in both TEAS and TVAS. Additional wavelength dependent TEAS measurements between 240–260 nm identify a threshold of 4.9 ± 0.1 eV (∼250 nm) for this photodetachment process in D2O. Analogous TEAS experiments on aqueous Ade at pD = 7.4 generate a similar photoproduct signal together with eaq(-) after excitation at 266 and 220 nm. These eaq(-) are born from ionization of Ade, together with Ade(+) cations, which are indistinguishable from Ade[-H] radicals in TEAS. Ade(+) and Ade[-H] are found to have different signatures in TVAS and we verify that the pD = 7.4 photoproduct signal observed in TEAS following 220 nm excitation is solely due to Ade(+) cations. Based on these observations, we conclude that: (i) N–H bond fission in aqueous Ade is inactive at wavelengths ≥220 nm; and (ii) if such a channel exists in aqueous solution, its threshold is strongly blue-shifted relative to the onset of the same process in gas phase 9H-Ade (≤233 nm). In addition, we extract excited state lifetimes and vibrational cooling dynamics for 9H-Ade and Ade[-H](-). In both cases, excited state lifetimes of <500 fs are identified, while vibrational cooling occurs within a time frame of 4–5 ps. In contrast, 7H

  11. Dynamics of Charged Excitons and Biexcitons in CsPbBr3 Perovskite Nanocrystals Revealed by Femtosecond Transient-Absorption and Single-Dot Luminescence Spectroscopy.

    Science.gov (United States)

    Yarita, Naoki; Tahara, Hirokazu; Ihara, Toshiyuki; Kawawaki, Tokuhisa; Sato, Ryota; Saruyama, Masaki; Teranishi, Toshiharu; Kanemitsu, Yoshihiko

    2017-04-06

    Metal-halide perovskite nanocrystals (NCs) are promising photonic materials for use in solar cells, light-emitting diodes, and lasers. The optoelectronic properties of these devices are determined by the excitons and exciton complexes confined in their NCs. In this study, we determined the relaxation dynamics of charged excitons and biexcitons in CsPbBr 3 NCs using femtosecond transient-absorption (TA), time-resolved photoluminescence (PL), and single-dot second-order photon correlation spectroscopy. Decay times of ∼40 and ∼200 ps were obtained from the TA and PL decay curves for biexcitons and charged excitons, respectively, in NCs with an average edge length of 7.7 nm. The existence of charged excitons even under weak photoexcitation was confirmed by the second-order photon correlation measurements. We found that charged excitons play a dominant role in luminescence processes of CsPbBr 3 NCs. Combining different spectroscopic techniques enabled us to clarify the dynamical behaviors of excitons, charged excitons, and biexcitons.

  12. Development and Characterization of a High Speed Mid-IR Tunable Diode Laser Absorption Spectrometer for CO and CO2 Detection in Detonation Events

    Science.gov (United States)

    2014-03-27

    fundamental equation for absorption spectroscopy follows from the Beer - Lambert Law , ( It I0 )v = e− S PxiφνL, (2.1) where S is the line-strength of a...data in frequency space, the Beer - Lambert law was applied in order to express the data in terms of absorption coefficient. This task was accomplished...according to an intensity where no absorption occurs according to Beer’s Law . Furthermore, the plots now focus on the regions of interest. For an

  13. Correlation spectrometer

    Science.gov (United States)

    Sinclair, Michael B [Albuquerque, NM; Pfeifer, Kent B [Los Lunas, NM; Flemming, Jeb H [Albuquerque, NM; Jones, Gary D [Tijeras, NM; Tigges, Chris P [Albuquerque, NM

    2010-04-13

    A correlation spectrometer can detect a large number of gaseous compounds, or chemical species, with a species-specific mask wheel. In this mode, the spectrometer is optimized for the direct measurement of individual target compounds. Additionally, the spectrometer can measure the transmission spectrum from a given sample of gas. In this mode, infrared light is passed through a gas sample and the infrared transmission signature of the gasses present is recorded and measured using Hadamard encoding techniques. The spectrometer can detect the transmission or emission spectra in any system where multiple species are present in a generally known volume.

  14. Development of a portable cavity-enhanced absorption spectrometer for the measurement of ambient NO3 and N2O5: experimental setup, lab characterizations, and field applications in a polluted urban environment

    Science.gov (United States)

    Wang, Haichao; Chen, Jun; Lu, Keding

    2017-04-01

    A small and portable incoherent broadband cavity-enhanced absorption spectrometer (IBBCEAS) for NO3 and N2O5 measurement has been developed. The instrument features a mechanically aligned non-adjustable optical mounting system, and the novel design of the optical mounting system enables a fast setup and stable operation in field applications. To remove the influence of the strong nonlinear absorption by water vapour, a dynamic reference spectrum through NO titration is used for the spectrum analysis. The wall loss effects of the sample system were extensively studied, and the total transmission efficiencies were determined to be 85 and 55 % for N2O5 and NO3, respectively, for our experimental setup. The limit of detection (LOD) was estimated to be 2.4 pptv (1σ) and 2.7 pptv (1σ) at 1 s intervals for NO3 and N2O5, respectively. The associated uncertainty of the field measurement was estimated to be 19 % for NO3 and 22-36 % for N2O5 measurements from the uncertainties of transmission efficiency, absorption cross section, effective cavity length, and mirror reflectivity. The instrument was successfully deployed in two comprehensive field campaigns conducted in the winter and summer of 2016 in Beijing. Up to 1.0 ppb NO3+N2O5 was observed with the presence of high aerosol loadings, which indicates an active night-time chemistry in Beijing.

  15. High gas temperature furnace for species determination of organometallic compounds with a high pressure liquid chromatograph and a Zeeman atomic absorption spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Koizumi, H.; McLaughlin, R.D.; Hadeishi, T.

    1979-03-01

    A new furnace has been constructed that allows atomic absorption detection of volatile organometallic compounds. The operation of this furnace is demonstrated by analyzing the eluent of a high pressure liquid chromatograph utilizing Zeeman atomic absorption spectrometry. The content of tetraethyllead in National Bureau of Standards gasoline standards was determined. Data are presented on the ability of this furnace to suppress interference with cadmium and lead determinations by MgCl/sub 2/, CuCl/sub 2/, and CaCl/sub 2/. It was found that two orders of magnitude more interferent can be tolerated. The determination of lead in automotive exhaust is also described. 7 figures, 4 tables.

  16. Multidimensional spectrometer

    Science.gov (United States)

    Zanni, Martin Thomas; Damrauer, Niels H.

    2010-07-20

    A multidimensional spectrometer for the infrared, visible, and ultraviolet regions of the electromagnetic spectrum, and a method for making multidimensional spectroscopic measurements in the infrared, visible, and ultraviolet regions of the electromagnetic spectrum. The multidimensional spectrometer facilitates measurements of inter- and intra-molecular interactions.

  17. The Use of a Microprocessor-Controlled, Video Output Atomic Absorption Spectrometer as an Educational Tool in a Two-Year Technical Curriculum.

    Science.gov (United States)

    Kerfoot, Henry B.

    Based on instructional experiences at Charles County Community College, Maryland, this report examines the pedagogical advantage of teaching atomic absorption (AA) spectroscopy with an AA spectrophotometer that is equipped with a microprocessor and video output mechanism. The report first discusses the growing importance of AA spectroscopy in…

  18. Compton backscattering axial spectrometer

    International Nuclear Information System (INIS)

    Rad'ko, V.E.; Mokrushin, A.D.; Razumovskaya, I.V.

    1981-01-01

    Compton gamma backscattering axial spectrometer of new design with the 200 time larger aperture as compared with the known spectrometers at the equal angular resolution (at E=159 keV) is described. Collimator unit, radiation source and gamma detector are located in the central part of the spectrometer. The investigated specimen (of cylindrical form) and the so called ''black body'' used for absorption of photons, passed through the specimen are placed in the peripheric part. Both these parts have an imaginary symmetry axis that is why the spectrometer is called axial. 57 Co is used as the gamma source. The 122 keV spectral line which corresponds to the 83 keV backscattered photon serves as working line. Germanium disk detector of 10 mm diameter and 4 mm height has energy resolution not worse than 900 eV. The analysis of results of test measurements of compton water profile and their comparison with data obtained earlier show that only finity of detector resolution can essentially affect the form of Compton profile. It is concluded that the suggested variant of the spectrometer would be useful for determination of Compton profiles of chemical compounds of heavy elements [ru

  19. Mass spectrometers

    International Nuclear Information System (INIS)

    Manojlov, V.E.; Nedelin, P.N.; Lukichev, A.N.; Sapozhkov, L.K.; Turubarov, V.I.

    1980-01-01

    Mass spectrometers of different types are suggested to use for qualitative and quantitative analyses of gas. The operation principles of static and dynamic mass spectrometer are studied. In static mass spectrometers mass separation of ions is performed by changing the value of accelerating voltage in the ion source when retaining the magnetic field intensity. Such devices are stationary. The device mass is conditioned by the magnet mass. Mass separation in dynamic mass spectrometers is dependent on the degree of energy increment of ions in HF-electric fields. Radio frequency mass spectrometers are used with advantage for studying upper layers of an atmosphere and are installed on radiosondes and satellites. The main technical characteristics of the MX-1330 mass spectrometer, the basis of which is the analyzer with 180 deg deviation of an ion beam in the field of permanent magnet, are presented. The device is intended for controlling the environment and permits to analyze gases with a molecular mass up to 450 using various systems of gas filling. The error of determination of molecular substance is not greater than +-3 %; the magnetic field intensity constitutes 4.8x10 5 A/m; the supply voltage is 380/220 V; the total power is 5.0 kVA [ru

  20. Narrative absorption

    DEFF Research Database (Denmark)

    Narrative Absorption brings together research from the social sciences and Humanities to solve a number of mysteries: Most of us will have had those moments, of being totally absorbed in a book, a movie, or computer game. Typically we do not have any idea about how we ended up in such a state. Nor...... do we fully realize how we might have changed as we return for the fictional worlds we have visited. The feeling of being absorbed is one of the most illusive and transient feelings, but also one that motivates audiences to spend considerable amounts of time in narrative worlds, and one...... that is central to our understanding of the effects of narratives on beliefs and behavior. Key specialists inform the reader of this book about the nature of the peculiar state of consciousness during episodes of absorption, the perception of absorption in history, the role of absorption in meaningful experiences...

  1. A differential optical absorption spectroscopy method for retrieval from ground-based Fourier transform spectrometers measurements of the direct solar beam

    Science.gov (United States)

    Huo, Yanfeng; Duan, Minzheng; Tian, Wenshou; Min, Qilong

    2015-08-01

    A differential optical absorption spectroscopy (DOAS)-like algorithm is developed to retrieve the column-averaged dryair mole fraction of carbon dioxide from ground-based hyper-spectral measurements of the direct solar beam. Different to the spectral fitting method, which minimizes the difference between the observed and simulated spectra, the ratios of multiple channel-pairs—one weak and one strong absorption channel—are used to retrieve from measurements of the shortwave infrared (SWIR) band. Based on sensitivity tests, a super channel-pair is carefully selected to reduce the effects of solar lines, water vapor, air temperature, pressure, instrument noise, and frequency shift on retrieval errors. The new algorithm reduces computational cost and the retrievals are less sensitive to temperature and H2O uncertainty than the spectral fitting method. Multi-day Total Carbon Column Observing Network (TCCON) measurements under clear-sky conditions at two sites (Tsukuba and Bremen) are used to derive xxxx for the algorithm evaluation and validation. The DOAS-like results agree very well with those of the TCCON algorithm after correction of an airmass-dependent bias.

  2. Photo ion spectrometer

    Science.gov (United States)

    Gruen, Dieter M.; Young, Charles E.; Pellin, Michael J.

    1989-01-01

    A charged particle spectrometer for performing ultrasensitive quantitative analysis of selected atomic components removed from a sample. Significant improvements in performing energy and angular refocusing spectroscopy are accomplished by means of a two dimensional structure for generating predetermined electromagnetic field boundary conditions. Both resonance and non-resonance ionization of selected neutral atomic components allow accumulation of increased chemical information. A multiplexed operation between a SIMS mode and a neutral atomic component ionization mode with EARTOF analysis enables comparison of chemical information from secondary ions and neutral atomic components removed from the sample. An electronic system is described for switching high level signals, such as SIMS signals, directly to a transient recorder and through a charge amplifier to the transient recorder for a low level signal pulse counting mode, such as for a neutral atomic component ionization mode.

  3. Zeeman atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Loos-Vollebregt, M.T.C. de.

    1980-01-01

    A new method of background correction in atomic absorption spectroscopy has recently been introduced, based on the Zeeman splitting of spectral lines in a magnetic field. A theoretical analysis of the background correction capability observed in such instruments is presented. A Zeeman atomic absorption spectrometer utilizing a 50 Hz sine wave modulated magnetic field is described. (Auth.)

  4. High-resolution three-dimensional imaging of a depleted CMOS sensor using an edge Transient Current Technique based on the Two Photon Absorption process (TPA-eTCT)

    Energy Technology Data Exchange (ETDEWEB)

    García, Marcos Fernández; Sánchez, Javier González; Echeverría, Richard Jaramillo [Instituto de Física de Cantabria (CSIC-UC), Avda. los Castros s/n, E-39005 Santander (Spain); Moll, Michael [CERN, Organisation europénne pour la recherche nucléaire, CH-1211 Genéve 23 (Switzerland); Santos, Raúl Montero [SGIker Laser Facility, UPV/EHU, Sarriena, s/n - 48940 Leioa-Bizkaia (Spain); Moya, David [Instituto de Física de Cantabria (CSIC-UC), Avda. los Castros s/n, E-39005 Santander (Spain); Pinto, Rogelio Palomo [Departamento de Ingeniería Electrónica, Escuela Superior de Ingenieros Universidad de Sevilla (Spain); Vila, Iván [Instituto de Física de Cantabria (CSIC-UC), Avda. los Castros s/n, E-39005 Santander (Spain)

    2017-02-11

    For the first time, the deep n-well (DNW) depletion space of a High Voltage CMOS sensor has been characterized using a Transient Current Technique based on the simultaneous absorption of two photons. This novel approach has allowed to resolve the DNW implant boundaries and therefore to accurately determine the real depleted volume and the effective doping concentration of the substrate. The unprecedented spatial resolution of this new method comes from the fact that measurable free carrier generation in two photon mode only occurs in a micrometric scale voxel around the focus of the beam. Real three-dimensional spatial resolution is achieved by scanning the beam focus within the sample.

  5. High-resolution three-dimensional imaging of a depleted CMOS sensor using an edge Transient Current Technique based on the Two Photon Absorption process (TPA-eTCT)

    CERN Document Server

    García, Marcos Fernández; Echeverría, Richard Jaramillo; Moll, Michael; Santos, Raúl Montero; Moya, David; Pinto, Rogelio Palomo; Vila, Iván

    2016-01-01

    For the first time, the deep n-well (DNW) depletion space of a High Voltage CMOS sensor has been characterized using a Transient Current Technique based on the simultaneous absorption of two photons. This novel approach has allowed to resolve the DNW implant boundaries and therefore to accurately determine the real depleted volume and the effective doping concentration of the substrate. The unprecedented spatial resolution of this new method comes from the fact that measurable free carrier generation in two photon mode only occurs in a micrometric scale voxel around the focus of the beam. Real three-dimensional spatial resolution is achieved by scanning the beam focus within the sample.

  6. Spectrometer gun

    Science.gov (United States)

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  7. Long-term field performance of a tunable diode laser absorption spectrometer for analysis of carbon isotopes of CO2 in forest air

    Directory of Open Access Journals (Sweden)

    D. R. Bowling

    2008-09-01

    Full Text Available Tunable diode laser absorption spectrometry (TDLAS is gaining in popularity for measuring the mole fraction [CO2] and stable isotopic composition (δ13C of carbon dioxide (CO2 in air in studies of biosphere-atmosphere gas exchange. Here we present a detailed examination of the performance of a commercially-available TDLAS located in a high-altitude subalpine coniferous forest (the Niwot Ridge AmeriFlux site, providing the first multi-year analysis of TDLAS instrument performance for measuring CO2 isotopes in the field. Air was sampled from five to nine vertical locations in and above the forest canopy every ten minutes for 2.4 years. A variety of methods were used to assess instrument performance. Measurement of two compressed air cylinders that were in place over the entire study establish the long-term field precision of 0.2 μmol mol−1 for [CO2] and 0.35‰ for δ13C, but after fixing several problems the isotope precision improved to 0.2permil (over the last several months. The TDLAS provided detail on variability of δ13C of atmospheric CO2 that was not represented in weekly flask samples, as well as information regarding the influence of large-scale (regional seasonal cycle and local forest processes on [CO2] and δ13C of CO2. There were also clear growing season and winter differences in the relative contributions of photosynthesis and respiration on the [CO2] and δ13C of forest air.

  8. Determination of tellurium at ultra-trace levels in drinking water by on-line solid phase extraction coupled to graphite furnace atomic absorption spectrometer

    International Nuclear Information System (INIS)

    Pedro, Juana; Stripekis, Jorge; Bonivardi, Adrian; Tudino, Mabel

    2008-01-01

    In this paper, two time-based flow injection (FI) separation pre-concentration systems coupled to graphite furnace atomic absorption spectrometry (GFAAS) for tellurium determination are studied and compared. The first alternative involves the pre-concentration of the analyte onto Dowex 1X8 employed as packaging material of a micro-column inserted in the flow system. The second set-up is based on the co-precipitation of tellurium with La(OH) 3 followed by retention onto XAD resins. Both systems are compared in terms of limit of detection, linear range, RSD%, sample throughput, micro-columns lifetime and aptitude for fully automatic operation. The features of the Dowex system are: 37% efficiency of retention and an enhancement factor of 42 for a pre-concentration time of 180 seconds (sample flow rate = 3 ml min -1 ) with acetic acid elution volumes of 80 μl. The detection limit (3 s) is 7 ng l -1 and the relative standard deviation (n = 7200 ng l -1 ) is 5.8%. The analytical performance of the XAD system is: 72% efficiency of retention and an enhancement factor of 25 for a pre-concentration time of 180 s (sample flow rate = 3 ml min -1 ) with nitric acid elution volumes of 300 μl. The detection limit is 66 ng l -1 and the relative standard deviation (n = 7200 ng l -1 ) is 8.3%. Applications to the determination of tellurium in tap water and the validation of the analytical methodology employing SRM 1643e as certified reference material are shown

  9. Villin promoter-mediated transgenic expression of transient receptor potential cation channel, subfamily V, member 6 (TRPV6) increases intestinal calcium absorption in wild-type and vitamin D receptor knockout mice.

    Science.gov (United States)

    Cui, Min; Li, Qiang; Johnson, Robert; Fleet, James C

    2012-10-01

    Transient receptor potential cation channel, subfamily V, member 6 (TRPV6) is an apical membrane calcium (Ca) channel in the small intestine proposed to be essential for vitamin D-regulated intestinal Ca absorption. Recent studies have challenged the proposed role for TRPV6 in Ca absorption. We directly tested intestinal TRPV6 function in Ca and bone metabolism in wild-type (WT) and vitamin D receptor knockout (VDRKO) mice. TRPV6 transgenic mice (TG) were made with intestinal epithelium-specific expression of a 3X Flag-tagged human TRPV6 protein. TG and VDRKO mice were crossed to make TG-VDRKO mice. Ca and bone metabolism was examined in WT, TG, VDRKO, and TG-VDRKO mice. TG mice developed hypercalcemia and soft tissue calcification on a chow diet. In TG mice fed a 0.25% Ca diet, Ca absorption was more than three-fold higher and femur bone mineral density (BMD) was 26% higher than WT. Renal 1α hydroxylase (CYP27B1) mRNA and intestinal expression of the natural mouse TRPV6 gene were reduced to intestine calbindin-D(9k) expression was elevated >15 times in TG mice. TG-VDRKO mice had high Ca absorption that prevented the low serum Ca, high renal CYP27B1 mRNA, low BMD, and abnormal bone microarchitecture seen in VDRKO mice. In addition, small intestinal calbindin D(9K) mRNA and protein levels were elevated in TG-VDRKO. Transgenic TRPV6 expression in intestine is sufficient to increase Ca absorption and bone density, even in VDRKO mice. VDR-independent upregulation of intestinal calbindin D(9k) in TG-VDRKO suggests this protein may buffer intracellular Ca during Ca absorption. © 2012 American Society for Bone and Mineral Research. Copyright © 2012 American Society for Bone and Mineral Research.

  10. Imaging ultrafast excited state pathways in transition metal complexes by X-ray transient absorption and scattering using X-ray free electron laser source

    DEFF Research Database (Denmark)

    Chen, Lin X; Shelby, Megan L; Lestrange, Patrick J

    2016-01-01

    orbital energies. A strong influence of the valence orbital occupation on the inner shell orbital energies indicates that one should not use the transition energy from 1s to other orbitals to draw conclusions about the d-orbital energies. For photocatalysis, a transient electronic configuration could...

  11. The Spectrometer

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2012-01-01

    In the fall of 1999 I was shown an Ocean Optics spectrometer-in-the-computer at St. Patricks College at Maynooth, Ireland, and thought that I had seen heaven. Of course, it could not resolve the sodium D-lines (I had done that many years before with a homemade wire diffraction grating), and I began to realize that inside was some familiar old…

  12. Ultra-fast X-ray absorption spectroscopy for the study of matter in transient regime; Spectroscopie d'absorption ultra-rapide de rayonnement X pour l'etude de la matiere en regime transitoire

    Energy Technology Data Exchange (ETDEWEB)

    Lecherbourg, L

    2007-12-15

    In this work, we study the physics of dense matter, plasmas or solids, using X-ray absorption spectroscopy. Through the use of sources produced by laser-matter interaction, we have measured the absorption spectra of aluminum and bromine plasmas, as well as those of vanadium dioxide (VO{sub 2}). The measurement of absorption coefficients allows us to probe the dense matter and to study its properties. The experiments are carried out following the same principle: they use the same experimental set-up, called pump-probe. When the matter is dense, the absorption properties of an atom are modified by the surrounding environment. In a plasma, it is mainly the bound- bound transitions which are altered: the shapes of those spectral rays are modified. In a solid, the position of the neighbouring atoms in relation to the absorbing atom modify the structure of absorption levels (bound-free transition). The study of this structure allows us to measure the parameters of the material, and provides information such as the state of the electronic band or the interatomic gaps. The experiments carried out at the LULI have allowed us to probe plasmas in the relatively unknown regime of the Warm Dense Matter. One of the key parameters is that the plasma is characterised independently (FDI diagnostic). It allows for a better comparison of the measured absorption against a calculation made with the numerical model OPA-S. The experiments carried out at INRS have led to the realisation of an experimental system having the characteristics which allow the study of the dynamics of solids showing ultra-fast phase transition. For those experiments, we have used vanadium dioxide as a model system allowing us to test the feasibility of the method. (author)

  13. MASS SPECTROMETER

    Science.gov (United States)

    White, F.A.

    1960-08-23

    A mass spectrometer is designed with a first adjustable magnetic field for resolving an ion beam into beams of selected masses, a second adjustable magnetic field for further resolving the ion beam from the first field into beams of selected masses, a thin foil disposed in the path of the beam between the first and second magnets to dissociate molecular ions incident thereon, an electrostatic field for further resolving the ion beam from the second field into beams of selected masses, and a detector disposed adjacent to the electrostatic field to receive the ion beam.

  14. Axis Spectrometer

    International Nuclear Information System (INIS)

    Park, Sungil

    2006-01-01

    The Cold Neutron Research Facility (CNRF) project carried out by Korea Atomic Energy Research Institute (KAERI) is an effort to bring cold neutron instrumentation to Korea's only large scale research reactor, HANARO, located in Daejeon. As part of the CNRF project, a cold neutron triple-axis spectrometer (Cold-TAS) is being developed along with other five: 40 m long and 12 m long small angle neutron scattering instruments (40m-SANS and 12m-SANS), disk-chopper time-of-flight spectrometer (DC-ToF), Bio- Reflectometer (Bio-REF) and the reflectometer with vertical sample geometry (REF-V). For those cold neutron instruments, the performance of an individual instrument depends not only on its design but also on the guide that feeds cold neutrons to the instrument. Therefore, the quality of the neutron flux at an instrument position has to be checked with the specification of the instrument. As for the Cold-TAS, since the instrument requires a tall beam and a high flux of short wavelength neutrons, it was tentatively decided that it would use the cold guide 4 (CG4). The detailed specification of the guide is listed. Checking the neutron flux of the guide at the instrument position is the obvious next step

  15. Development of an airborne three-channel LED-based broadband cavity enhanced absorption spectrometer: towards an improved understanding of nighttime chemistry of NO3 and N2O5 in northwest Europe

    Science.gov (United States)

    Ouyang, Bin

    2015-04-01

    A three-channel cavity-enhanced absorption spectrometer capable of covering a broad UV-vis spectrum range has been developed in Cambridge for deployment on board the UK FAAM BAe-146 atmospheric research aircraft for measuring in situ concentrations of important atmospheric absorbers such as NO3, N2O5, NO2, IO and H2O and also aerosol extinction. So far this instrument has been deployed in two aircraft campaigns (the ROle of Nighttime chemistry in controlling the Oxidative Capacity of the atmOsphere, RONOCO, during July 2010 and January 2011; and the Coordinated Airborne Studies in the Tropics, CAST, during February 2014) with focuses on measuring NO2/NO3/N2O5 (for RONOCO) and IO (for CAST). In this talk, I will start by briefly presenting the working principle, design consideration, sensitivity test as well as intercomparison results of this novel aircraft instrument. I will then move on to present recent results from the analysis of the RONOCO campaign data, to illustrate the spatial and temporal variability of nighttime chemistry processes revealed by the high-resolution NO3 and N2O5 data collected. Significant improvements were made towards a better understanding of the oxidation of reactive VOCs by NO3 and O3 and the contribution of peroxy radicals (HO2 and RO2, of which only HO2 was successfully measured) to NO3 direct losses, and towards determining factors (organics and nitrate components of the aerosol particles, and relative humidity) that greatly influence the rate of N2O5 uptake by aerosol particles as well as directly probing the role of cloud, rain and ice scavenging in removing N2O5, in this typical northwest European environment.

  16. Gamow-Teller decay and nuclear deformation: implementing of a new total absorption spectrometer, study of isotopes N {approx_equal} Z krypton and strontium; Decroissance Gamow-Teller et deformation nucleaire: mise en oeuvre d'un nouveau spectrometre a absorption totale, etude d'isotopes N {approx_equal} Z de krypton et strontium

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, E

    2002-12-01

    Nuclei with A {approx} 70 along the N=Z line are known to be the scene of phenomena closely related to the nuclear deformation and are of particular interest since theoretical mean field calculations predict that a large part of the Gamow-Teller resonance might be located below the ground state of the mother nucleus and then be accessible through {beta}-decay studies. These results have shown the effect of the shape of the ground state on the intensity of the Gamow-Teller strength. Thus, the experimental determination, through {delta}-decay, of the Gamow-Teller strength distribution and the comparison to the theoretical predictions allow to pin down the quadrupolar deformation parameter of the ground state of the parent nucleus. In order to study the neutron deficient isotopes of krypton (A=72,73,74,75) and strontium (A=76,77,78) and to establish the {beta}-strength on the full energy range, a new total absorption spectrometer (TAgS) has been built in the frame of an international collaboration and installed at the (SOLDE/CERN mass separator. For the data analysis, the response function R of the spectrometer has been calculated by means of Monte-Carlo simulations, based on the GEANT4 code, and of a statistical description of the level scheme in the daughter nucleus. The {beta}-feeding distribution has been obtained from experimental spectra through a method based on Bayes theorem and then converted into Gamow-Teller strength. The results coming from the {sup 74}Kr decay analysis allow to describe the ground state of such a nucleus as the coexistence of an oblate shape and of a prolate shape. In the case of {sup 76}Sr, the experimental Gamow-Teller strength distribution strongly indicates a prolate deformation. (author)

  17. A strong steric hindrance effect on ground state, excited state, and charge separated state properties of a CuI-diimine complex captured by X-ray transient absorption spectroscopy

    DEFF Research Database (Denmark)

    Huang, J.; Mara, M.W.; Stickrath, A.B.

    2014-01-01

    Photophysical and structural properties of a CuI diimine complex with very strong steric hindrance, [CuI(dppS)2]+ (dppS = 2,9-diphenyl-1,10-phenanthroline disulfonic acid disodium salt), are investigated by optical and X-ray transient absorption (OTA and XTA) spectroscopy. The bulky phenylsulfonic...... dynamics and structures as well as those of the charge separated state resulting from the interfacial electron injection from the MLCT state to TiO2 nanoparticles (NPs). The OTA results show the absence of the sub-picosecond component previously assigned as the time constant for flattening, while the two...... of metal complex/semiconductor NP hybrids but also provide guidance for designing efficient CuI diimine complexes with optimized structures for application in solar-to-electricity conversion. This journal is...

  18. Near shot-noise limited time-resolved circular dichroism pump-probe spectrometer

    Science.gov (United States)

    Stadnytskyi, Valentyn; Orf, Gregory S.; Blankenship, Robert E.; Savikhin, Sergei

    2018-03-01

    We describe an optical near shot-noise limited time-resolved circular dichroism (TRCD) pump-probe spectrometer capable of reliably measuring circular dichroism signals in the order of μdeg with nanosecond time resolution. Such sensitivity is achieved through a modification of existing TRCD designs and introduction of a new data processing protocol that eliminates approximations that have caused substantial nonlinearities in past measurements and allows the measurement of absorption and circular dichroism transients simultaneously with a single pump pulse. The exceptional signal-to-noise ratio of the described setup makes the TRCD technique applicable to a large range of non-biological and biological systems. The spectrometer was used to record, for the first time, weak TRCD kinetics associated with the triplet state energy transfer in the photosynthetic Fenna-Matthews-Olson antenna pigment-protein complex.

  19. Quantifying ultrafast charge carrier injection from methylammonium lead iodide into the hole-transport material H101 and mesoporous TiO2using Vis-NIR transient absorption.

    Science.gov (United States)

    Klein, Johannes R; Scholz, Mirko; Oum, Kawon; Lenzer, Thomas

    2017-07-21

    Organic-inorganic hybrid lead halide perovskites already reach very high power conversion efficiencies above 22% on architectures employing mesoporous TiO 2 , but the carrier injection processes across the different interfaces are still not fully understood. Here we use ultrafast broadband transient absorption spectroscopy to determine time constants and yields for hole and electron injection. We show that hole transfer from the perovskite valence band (VB) to the hole-transport material (HTM) H101 at the perovskite/HTM interface occurs in less than 500 fs, but is limited by imperfections of the contact layer and poor infiltration of the HTM into the mesoporous structure. Electron injection from the perovskite conduction band (CB) into the CB of mesoporous TiO 2 is only a small channel (25%). Electron transport inside mesoporous MAPI/TiO 2 architectures therefore mainly occurs via the perovskite. We also show that electron injection from H101 into the perovskite is feasible for excitation at 400 nm resulting in light-harvesting of high-energy photons by the HTM. Accurate absolute NIR absorption coefficients for CB electrons in mesoporous TiO 2 are provided.

  20. Fourier Transform Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — The Fourier Transform Spectrometer project demonstrates the efficacy of a miniaturized spectrometer for flight applications.A spectrometer is an instrument used to...

  1. Extensive reduction in back electron transfer in twisted intramolecular charge-transfer (TICT) coumarin-dye-sensitized TiO(2) nanoparticles/film: a femtosecond transient absorption study.

    Science.gov (United States)

    Debnath, Tushar; Maity, Partha; Lobo, Hyacintha; Singh, Balvant; Shankarling, Ganapati S; Ghosh, Hirendra N

    2014-03-17

    We report the synthesis, characterization, and optical and electrochemical properties of two structurally similar coumarin dyes (C1 and C2). These dyes have been deployed as sensitizers in TiO2 nanoparticles and thin films, and the effect of molecular structure on interfacial electron-transfer dynamics has been studied. Steady-state optical absorption, emission, and time-resolved emission studies on both C1 and C2, varying the polarity of the solvent and the solution pH, suggest that both photoexcited dyes exist in a locally excited (LE) state in solvents of low polarity. In highly polar solvents, however, C1 exists in an intramolecular charge-transfer (ICT) state, whereas C2 exists in both ICT and twisted intramolecular charge-transfer (TICT) states, their populations depending on the degree of polarity of the solvent and the pH of the solution. We have employed femtosecond transient absorption spectroscopy to monitor the charge-transfer dynamics in C1- and C2-sensitized TiO2 nanoparticles and thin films. Electron injection has been confirmed by direct detection of electrons in the conduction band of TiO2 nanoparticles and of radical cations of the dyes in the visible and near-IR regions of the transient absorption spectra. Electron injection in both the C1/TiO2 and C2/TiO2 systems has been found to be pulse-width limited (<100 fs); however, back-electron-transfer (BET) dynamics has been found to be slower in the C2/TiO2 system than in the C1/TiO2 system. The involvement of TICT states in C2 is solely responsible for the higher electron injection yield as well as the slower BET process compared to those in the C1/TiO2 system. Further pH-dependent experiments on C1- and C2-sensitized TiO2 thin films have corroborated the participation of the TICT state in the slower BET process in the C2/TiO2 system. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Smartphone Spectrometers

    Science.gov (United States)

    Willmott, Jon R.; Mims, Forrest M.; Parisi, Alfio V.

    2018-01-01

    Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades. PMID:29342899

  3. Smartphone Spectrometers

    Directory of Open Access Journals (Sweden)

    Andrew J.S. McGonigle

    2018-01-01

    Full Text Available Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades.

  4. Smartphone Spectrometers.

    Science.gov (United States)

    McGonigle, Andrew J S; Wilkes, Thomas C; Pering, Tom D; Willmott, Jon R; Cook, Joseph M; Mims, Forrest M; Parisi, Alfio V

    2018-01-14

    Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a 'lab in a phone' capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades.

  5. Evaluating the Nature of So-Called S*-State Feature in Transient Absorption of Carotenoids in Light-Harvesting Complex 2 (LH2) from Purple Photosynthetic Bacteria.

    Science.gov (United States)

    Niedzwiedzki, Dariusz M; Hunter, C Neil; Blankenship, Robert E

    2016-11-03

    Carotenoids are a class of natural pigments present in all phototrophic organisms, mainly in their light-harvesting proteins in which they play roles of accessory light absorbers and photoprotectors. Extensive time-resolved spectroscopic studies of these pigments have revealed unexpectedly complex photophysical properties, particularly for carotenoids in light-harvesting LH2 complexes from purple bacteria. An ambiguous, optically forbidden electronic excited state designated as S* has been postulated to be involved in carotenoid excitation relaxation and in an alternative carotenoid-to-bacteriochlorophyll energy transfer pathway, as well as being a precursor of the carotenoid triplet state. However, no definitive and satisfactory origin of the carotenoid S* state in these complexes has been established, despite a wide-ranging series of studies. Here, we resolve the ambiguous origin of the carotenoid S* state in LH2 complex from Rba. sphaeroides by showing that the S* feature can be seen as a combination of ground state absorption bleaching of the carotenoid pool converted to cations and the Stark spectrum of neighbor neutral carotenoids, induced by temporal electric field brought by the carotenoid cation-bacteriochlorophyll anion pair. These findings remove the need to assign an S* state, and thereby significantly simplify the photochemistry of carotenoids in these photosynthetic antenna complexes.

  6. Ultrafast carrier dynamics unravel role of surface ligands and metal domain size on the photocatalytic hydrogen evolution efficiency of Au-tipped CdS nanorods: an ultrafast transient absorption spectroscopy study

    Science.gov (United States)

    Ben-Shahar, Yuval; Kriegel, Ilka; Scotognella, Francesco; Waiskopf, Nir; Dal Conte, Stefano; Moretti, Luca; Cerullo, Giulio; Rabani, Eran; Banin, Uri

    2017-02-01

    Semiconductor-metal hybrid nanostructures are interesting materials for photocatalysis. Their tunable properties offer a highly controllable platform to design light-induced charge separation, a key to their function in photocatalytic water splitting. Hydrogen evolution quantum yields are influenced by factors as size, shape, material and morphology of the system, additionally the surface coating or the metal domain size play a dominant role. In this paper we present a study on a well-defined model system of Au-tipped CdS nanorods. We use transient absorption spectroscopy to get insights into the charge carrier dynamics after photoexcitation of the bandgap of CdS nanorods. The study of charge transfer processes combined with the hydrogen evolution efficiency unravels the effects of surface coating and the gold tip size on the photocatalytic efficiency. Differences in efficiency with various surface ligands are primarily ascribed to the effects of surface passivation. Surface trapping of charge carriers is competing with effective charge separation, a prerequisite for photocatalysis, leading to the observed lower hydrogen production quantum yields. Interestingly, non-monotonic hydrogen evolution efficiency with size of the gold tip is observed, resulting in an optimal metal domain size for the most efficient photocatalysis. These results are explained by the sizedependent interplay of the metal domain charging and the relative band-alignments. Taken together our findings are of major importance for the potential application of hybrid nanoparticles as photocatalysts.

  7. Mid infrared MEMS FTIR spectrometer

    Science.gov (United States)

    Erfan, Mazen; Sabry, Yasser M.; Mortada, Bassem; Sharaf, Khaled; Khalil, Diaa

    2016-03-01

    In this work we report, for the first time to the best of our knowledge, a bulk-micromachined wideband MEMS-based spectrometer covering both the NIR and the MIR ranges and working from 1200 nm to 4800 nm. The core engine of the spectrometer is a scanning Michelson interferometer micro-fabricated using deep reactive ion etching (DRIE) technology. The spectrum is obtained using the Fourier Transform techniques that allows covering a very wide spectral range limited by the detector responsivity. The moving mirror of the interferometer is driven by a relatively large stroke electrostatic comb-drive actuator. Zirconium fluoride (ZrF4) multimode optical fibers are used to connect light between the white light source and the interferometer input, as well as the interferometer output to a PbSe photoconductive detector. The recorded signal-to-noise ratio is 25 dB at the wavelength of 3350 nm. The spectrometer is successfully used in measuring the absorption spectra of methylene chloride, quartz glass and polystyrene film. The presented solution provides a low cost method for producing miniaturized spectrometers in the near-/mid-infrared.

  8. Triple-axis spectrometer

    International Nuclear Information System (INIS)

    Toeroek, Gy.

    2001-01-01

    A triple-axis spectrometer has been designed for structural and dynamical studies of condensed matter. Because of the limited number of other operational equipment the triple axis spectrometer was used in a multi purpose regime, e.g. high resolution diffractometry, strain analysis, reflectometry, quasielastic and inelastic scattering. A polarization setup was also tested on this spectrometer. (R.P.)

  9. Transient analyzer

    International Nuclear Information System (INIS)

    Muir, M.D.

    1975-01-01

    The design and design philosophy of a high performance, extremely versatile transient analyzer is described. This sub-system was designed to be controlled through the data acquisition computer system which allows hands off operation. Thus it may be placed on the experiment side of the high voltage safety break between the experimental device and the control room. This analyzer provides control features which are extremely useful for data acquisition from PPPL diagnostics. These include dynamic sample rate changing, which may be intermixed with multiple post trigger operations with variable length blocks using normal, peak to peak or integrate modes. Included in the discussion are general remarks on the advantages of adding intelligence to transient analyzers, a detailed description of the characteristics of the PPPL transient analyzer, a description of the hardware, firmware, control language and operation of the PPPL transient analyzer, and general remarks on future trends in this type of instrumentation both at PPPL and in general

  10. Frequency-modulation transient absorption spectrum of the HCCl A 1A double-prime(0,0,0)left-arrow X 1A'(0,0,0) transition

    International Nuclear Information System (INIS)

    Chang, B.; Sears, T.J.

    1995-01-01

    The rotationally resolved spectrum of the HCCl A 1 A double-prime(0,0,0)left-arrow X 1 A'(0,0,0) transition between 12 230 and 12 410 cm -1 was obtained for the first time at Doppler-limited resolution using a frequency-modulation (FM) transient absorption technique. Five major subbands (K a =0 left-arrow 1, 1 left-arrow 0, 1 left-arrow 2, 2 left-arrow 1, and 2 left-arrow 3) of HC 35 Cl and one subband (K a =0 left-arrow 1) of HC 37 Cl were observed and assigned. In addition, the forbidden subband (K a =0 left-arrow 0) of HC 35 Cl was also observed. Thus far, we have assigned most (more than 70%) of the strong lines. The analysis of these subbands determines the geometry for the HCCl A(0,0,0) level: angle HCCl=134.7 degree and R C-Cl =1.623 A while R C-H is fixed at the corresponding value of CH 2 . The height of the barrier to linearity was found to be approximately 2170 cm -1 above the vibrationless level of the A state. The rotational structure of this spectrum shows irregular perturbations. Both random and J-dependent (anomalous K-type doubling) effects were observed. As in methylene, the perturbations most likely arise from Renner--Teller effect between the two singlet states in combination with spin--orbit coupling between the singlet and triplet states

  11. MASERATI: a new rocket-borne diode laser absorption spectrometer for in-situ measurement of trace gases in the middle and upper atmosphere; MASERATI: Ein neues raketengetragenes Diodenlaser-Absorptionsspektrometer zur in situ-Messung von Spurengasen in der mittleren und oberen Atmosphaere

    Energy Technology Data Exchange (ETDEWEB)

    Lucke, H. von

    1999-09-01

    MASERATI (middle atmosphere spectrometric experiment on Rockets for the analysis of trace gas influences) is the first rocket-borne tunable diode laser absorption spectrometer (TDLAS). It was developed to measure water vapor and carbon dioxide in the altitude range from 50 to 90 km and 120 km, respectively. Infrared absorption spectroscopy using two laser diodes is applied to measure both trace gases simultaneously. The laser beams are sent into an open multiple-pass absorption setup mounted on top of the sounding rocket. High sensitivity is achieved by means of frequency modulation and lock-in techniques. The results of several tests performed in the laboratory demonstrate that the instrument is capable of detecting relative absorbances down to 10{sup -4} - 10{sup -5} when integrating spectra for 1 s. Two almost identical MASERATI instruments have been built and launched on sounding rockets from the Andoeya rocket range (69 N, 16 E) in northern Norway during winter 1997/98. The results of these flights demonstrate that MASERATI is a new suitable tool for in situ studies of the mesosphere and lower thermosphere. (orig.)

  12. Spherical grating spectrometers

    Science.gov (United States)

    O'Donoghue, Darragh; Clemens, J. Christopher

    2014-07-01

    We describe designs for spectrometers employing convex dispersers. The Offner spectrometer was the first such instrument; it has almost exclusively been employed on satellite platforms, and has had little impact on ground-based instruments. We have learned how to fabricate curved Volume Phase Holographic (VPH) gratings and, in contrast to the planar gratings of traditional spectrometers, describe how such devices can be used in optical/infrared spectrometers designed specifically for curved diffraction gratings. Volume Phase Holographic gratings are highly efficient compared to conventional surface relief gratings; they have become the disperser of choice in optical / NIR spectrometers. The advantage of spectrometers with curved VPH dispersers is the very small number of optical elements used (the simplest comprising a grating and a spherical mirror), as well as illumination of mirrors off axis, resulting in greater efficiency and reduction in size. We describe a "Half Offner" spectrometer, an even simpler version of the Offner spectrometer. We present an entirely novel design, the Spherical Transmission Grating Spectrometer (STGS), and discuss exemplary applications, including a design for a double-beam spectrometer without any requirement for a dichroic. This paradigm change in spectrometer design offers an alternative to all-refractive astronomical spectrometer designs, using expensive, fragile lens elements fabricated from CaF2 or even more exotic materials. The unobscured mirror layout avoids a major drawback of the previous generation of catadioptric spectrometer designs. We describe laboratory measurements of the efficiency and image quality of a curved VPH grating in a STGS design, demonstrating, simultaneously, efficiency comparable to planar VPH gratings along with good image quality. The stage is now set for construction of a prototype instrument with impressive performance.

  13. Millimeterwave spectroscopy of transient molecules produced in a ...

    Indian Academy of Sciences (India)

    The construction of a millimeterwave spectrometer to study the pure rotational spectra of transient molecules in the gas phase is presented. The spectrometer is a source-modulated system combined with a free space glass discharge cell. Millimeterwave radiation has been produced using a frequency multiplier, the ...

  14. Spectrometer Baseline Control Via Spatial Filtering

    Science.gov (United States)

    Burleigh, M. R.; Richey, C. R.; Rinehart, S. A.; Quijada, M. A.; Wollack, E. J.

    2016-01-01

    An absorptive half-moon aperture mask is experimentally explored as a broad-bandwidth means of eliminating spurious spectral features arising from reprocessed radiation in an infrared Fourier transform spectrometer. In the presence of the spatial filter, an order of magnitude improvement in the fidelity of the spectrometer baseline is observed. The method is readily accommodated within the context of commonly employed instrument configurations and leads to a factor of two reduction in optical throughput. A detailed discussion of the underlying mechanism and limitations of the method are provided.

  15. The SPEDE spectrometer

    Science.gov (United States)

    Papadakis, P.; Cox, D. M.; O'Neill, G. G.; Borge, M. J. G.; Butler, P. A.; Gaffney, L. P.; Greenlees, P. T.; Herzberg, R.-D.; Illana, A.; Joss, D. T.; Konki, J.; Kröll, T.; Ojala, J.; Page, R. D.; Rahkila, P.; Ranttila, K.; Thornhill, J.; Tuunanen, J.; Van Duppen, P.; Warr, N.; Pakarinen, J.

    2018-03-01

    The electron spectrometer, SPEDE, has been developed and will be employed in conjunction with the Miniball spectrometer at the HIE-ISOLDE facility, CERN. SPEDE allows for direct measurement of internal conversion electrons emitted in-flight, without employing magnetic fields to transport or momentum filter the electrons. Together with the Miniball spectrometer, it enables simultaneous observation of γ rays and conversion electrons in Coulomb excitation experiments using radioactive ion beams.

  16. The Omicron Spectrometer

    CERN Document Server

    Allardyce, B W

    1976-01-01

    It is intended to build a spectrometer with a large solid angle and a large momentum acceptance at the reconstructed synchrocyclotron at CERN. This spectrometer will have an energy resolution of about 1 MeV for particles with momenta up to about 400 MeV/c.

  17. Adaptive Tunable Laser Spectrometer for Space Applications

    Science.gov (United States)

    Flesch, Gregory; Keymeulen, Didier

    2010-01-01

    An architecture and process for the rapid prototyping and subsequent development of an adaptive tunable laser absorption spectrometer (TLS) are described. Our digital hardware/firmware/software platform is both reconfigurable at design time as well as autonomously adaptive in real-time for both post-integration and post-launch situations. The design expands the range of viable target environments and enhances tunable laser spectrometer performance in extreme and even unpredictable environments. Through rapid prototyping with a commercial RTOS/FPGA platform, we have implemented a fully operational tunable laser spectrometer (using a highly sensitive second harmonic technique). With this prototype, we have demonstrated autonomous real-time adaptivity in the lab with simulated extreme environments.

  18. Probing ultrafast carrier dynamics, nonlinear absorption and ...

    Indian Academy of Sciences (India)

    diameter of about 60 nm of the core–shell silicon nanowires, (b) linear optical absorption measurement using a visible–infrared absorption spectrometer. on the nanowires and on the substrate [9]. The overall thickness of the silicon nanowire film was ∼600 nm measured independently using atomic force microscopy ...

  19. Ultrasonic absorption

    International Nuclear Information System (INIS)

    Beyer, R.T.

    1985-01-01

    The paper reviews studies of ultrasonic absorption in liquid alkali metals. The experimental methods to measure the absorption coefficients are briefly described. Experimental results reported for the liquid metals: sodium, potassium, rubidium and caesium, at medium temperatures, are presented, as well as data for liquid alloys. Absorption losses due to the presence of an external magnetic field, and the effects of viscosity on the absorption in metals, are both discussed. (U.K.)

  20. Transient behaviour of an adsorption refrigerator. Experimental study of the alcohol/activated carbon system; Comportement transitoire d`une machine frigorifique a absorption. Etude experimentale du systeme alcool / charbon actif

    Energy Technology Data Exchange (ETDEWEB)

    Luo, L. [Centre National de la Recherche Scientifique (CNRS), 54 - Nancy (France). Lab. des sciences du genie chimique; Feidt, M. [Nancy-1 Univ., 54 - Vandoeuvre-les-Nancy (France)

    1997-03-01

    The objective of this article is to present an experimental study of an adsorption refrigerator, accounting for the transient phenomena in each component of the machine, in particular in the adsorber. The couples adsorbate/adsorbent investigated (activated carbon/methanol or ethanol) have been chosen on the basis of an earlier comparative study. We have performed a full series of experiments to investigate the transient evolution of temperatures, pressures and the cycled mass, in a discontinuous cycle, and along the components of the refrigerating machine. The influence of various parameters is studies by varying one at a time: adsorbate/ adsorbent couple, alcohol load in adsorber, alcohol flowrate, heating power, initial desorption temperature. All these experimental observation are discussed and compared to transient models developed in a separate article. (authors) 12 refs.

  1. Fourier Transform Spectrometer System

    Science.gov (United States)

    Campbell, Joel F. (Inventor)

    2014-01-01

    A Fourier transform spectrometer (FTS) data acquisition system includes an FTS spectrometer that receives a spectral signal and a laser signal. The system further includes a wideband detector, which is in communication with the FTS spectrometer and receives the spectral signal and laser signal from the FTS spectrometer. The wideband detector produces a composite signal comprising the laser signal and the spectral signal. The system further comprises a converter in communication with the wideband detector to receive and digitize the composite signal. The system further includes a signal processing unit that receives the composite signal from the converter. The signal processing unit further filters the laser signal and the spectral signal from the composite signal and demodulates the laser signal, to produce velocity corrected spectral data.

  2. Improved Mass Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Improved Mass Spectrometer project will develop system requirements and analyze the path to space qualification.   The results of this project...

  3. Micro Plasma Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of this IRAD project is to develop a preliminary design elements of miniature electron and ion plasma spectrometers and supporting electronics, focusing...

  4. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  5. Neutral Kaon Spectrometer 2

    Science.gov (United States)

    Kaneta, M.; Beckford, B.; Fujii, T.; Fujii, Y.; Futatsukawa, K.; Han, Y. C.; Hashimoto, O.; Hirose, K.; Ishikawa, T.; Kanda, H.; Kimura, C.; Maeda, K.; Nakamura, S. N.; Suzuki, K.; Tsukada, K.; Yamamoto, F.; Yamazaki, H.

    2018-04-01

    A large-acceptance spectrometer, Neutral Kaon Spectrometer 2 (NKS2), was newly constructed to explore various photoproduction reactions in the gigaelectronvolt region at the Laboratory of Nuclear Science (LNS, currently ELPH), Tohoku University. The spectrometer consisted of a dipole magnet, drift chambers, and plastic scintillation counters. NKS2 was designed to separate pions and protons in a momentum range of less than 1 GeV/ c, and was placed in a tagged photon beamline. A cryogenic H2/D2 target fitted to the spectrometer were designed. The design and performance of the detectors are described. The results of the NKS2 experiment on analyzing strangeness photoproduction data using a 0.8-1.1 GeV tagged photon beam are also presented.

  6. The dilepton spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Yegneswaran, A.; Claesson, G.; Fulton, R.; Hendrie, D.L.; Krebs, G.F.; Lallier, E.; Letessier-Selvon, A.; Matis, H.S.; Mulera, T.; Naudet, C.; Nesbitt, D.; Roche, G.; Schroeder, L.S.; Seidl, P.A. (Lawrence Berkeley Lab., CA (USA)); Beedoe, S.; Bystricky, J.; Carroll, J.; Gordon, J.; Igo, G.; Oillataguerre, P. (California Univ., Los Angeles (USA)); Christo, S.; Gilot, J.F.; Kirk, P.; Wang, Z.; Xu, I. (Louisiana State Univ., Baton Rouge (USA)); Force, P.; Landaud, G. (Clermont-Ferrand-2 Univ., 63 - Aubiere (France)); Hallman, T.; Madansky, L.; Welsh, R. (Johns Hopkins Univ., Baltimore, MD (USA)); Miller, D. (Northwestern Univ., Evanston, IL (USA))

    1990-05-01

    The dilepton spectrometer (DLS) at Lawrence Berkeley Laboratory's Bevalac has been designed and constructed to investigate the production of electron-positron pairs with low mass and low transverse momentum in proton-nucleus and nucleus-nucleus collisions for incident-beam kinetic energies of 5 A GeV and less. This article briefly recalls the physics objectives of the program, discusses the methodology of the measurement, presents details of the design of the spectrometer and the detector elements, and reports on their performance. Selected experimental results are given to illustrate the capability of the DLS and to demonstrate the level to which it is possible to realize the physics objectives with the spectrometer. (orig.).

  7. Absorption studies

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Absorption studies were once quite popular but hardly anyone does them these days. It is easier to estimate the blood level of the nutrient directly by radioimmunoassay (RIA). However, the information obtained by estimating the blood levels of the nutrients is not the same that can be obtained from the absorption studies. Absorption studies are primarily done to find out whether some of the essential nutrients are absorbed from the gut or not and if they are absorbed, to determine how much is being absorbed. In the advanced countries, these tests were mostly done to detect pernicious anaemia where vitamin B 12 is not absorbed because of the lack of the intrinsic factor in the stomach. In the tropical countries, ''malabsorption syndrome'' is quire common. In this condition, several nutrients like fat, folic acid and vitamin B 12 are not absorbed. It is possible to study absorption of these nutrients by radioisotopic absorption studies

  8. Ultraviolet photoelectron spectroscopy of transient species

    International Nuclear Information System (INIS)

    Leeuw, D.M. de.

    1979-01-01

    Transient species are studied in the isolation of the gas phase using ultraviolet photoelectron spectroscopy (PES). A description of the equipment used and a discussion of some theoretical topics, which play a role in the interpretation of PE spectra, are given. Koopmans' theorem, Hartree-Fock-Slater (HFS) calculations and the sum rule are discussed. A versatile ultraviolet PE spectrometer, designed specifically for this purpose, has been built and the construction and performance of this instrument are described. (Auth.)

  9. The Omega spectrometer

    CERN Multimedia

    1972-01-01

    The Omega spectrometer which came into action during the year. An array of optical spark chambers can be seen withdrawn from the magnet aperture. In the 'igloo' above the magnet is located the Plumbicon camera system which collects information from the spark chambers.

  10. Speckle-based spectrometer

    DEFF Research Database (Denmark)

    Chakrabarti, Maumita; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2015-01-01

    A novel spectrometer concept is analyzed and experimentally verified. The method relies on probing the speckle displacement due to a change in the incident wavelength. A rough surface is illuminated at an oblique angle, and the peak position of the covariance between the speckle patterns observed...

  11. MIRI spectrometer optical design

    NARCIS (Netherlands)

    Kruizinga, B.; Visser, H.; Pel, J.W.; Moddemeijer, K.; Smorenburg, C.

    2004-01-01

    MIRI (the Mid InfraRed Instrument) is one of the focal plane instruments of the James Webb Space Telescope. The instrument comprises a camera and a spectrometer module. The instrument plays the following key roles in the JWST science program. Discovery of the "first light". Assembly of galaxies:

  12. Magnetic spectrometer Grand Raiden

    International Nuclear Information System (INIS)

    Fujiwara, M.; Akimune, H.; Daito, I.; Fujimura, H.; Fujita, Y.; Hatanaka, K.; Ikegami, H.; Katayama, I.; Nagayama, K.; Matsuoka, N.; Morinobu, S.; Noro, T.; Yoshimura, M.; Sakaguchi, H.; Sakemi, Y.; Tamii, A.; Yosoi, M.

    1999-01-01

    A high-resolution magnetic spectrometer called 'Grand Raiden' is operated at the RCNP ring cyclotron facility in Osaka for nuclear physics studies at intermediate energies. This magnetic spectrometer has excellent ion-optical properties. In the design of the spectrometer, the second-order dispersion matching condition has been taken into account, and almost all the aberration terms such as (x vertical bar θ 3 ), (x vertical bar θφ 2 ), (x vertical bar θ 2 δ) and (x vertical bar θδ 2 ) in a third-order matrix calculation are optimized. A large magnetic rigidity of the spectrometer (K = 1400 MeV) gives a great advantage to measure the charge-exchange ( 3 He, t) reactions at 450 MeV. The ability of the high-resolution measurement has been demonstrated. Various coincidence measurements are performed to study the nuclear structures of highly excited states through decay properties of nuclear levels following nuclear reactions at intermediate energies

  13. In Situ Mass Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The In Situ Mass Spectrometer projects focuses on a specific subsystem to leverage advanced research for laser-based in situ mass spectrometer development...

  14. Folate absorption

    International Nuclear Information System (INIS)

    Baker, S.J.

    1976-01-01

    Folate is the generic term given to numerous compounds of pteroic acid with glutamic acid. Knowledge of absorption is limited because of the complexities introduced by the variety of compounds and because of the inadequacy of investigational methods. Two assay methods are in use, namely microbiological and radioactive. Techniques used to study absorption include measurement of urinary excretion, serum concentration, faecal excretion, intestinal perfusion, and haematological response. It is probably necessary to test absorption of both pteroylmonoglutamic acid and one or more polyglutamates, and such tests would be facilitated by availability of synthesized compounds labelled with radioactive tracers at specifically selected sites. (author)

  15. Characterization of MEMS FTIR spectrometer

    Science.gov (United States)

    Khalil, Diaa; Sabry, Yasser; Omran, Haitham; Medhat, Mostafa; Hafez, Amr; Saadany, Bassam

    2011-03-01

    In this work we present the full characterization of an optical MEMS Fourier Transform Infra Red FTIR spectrometer fabricated by Deep Reactive Ion Etching DRIE Technology on Silicon substrate. Both electrical and optical properties of the spectrometer are measured. The presented techniques allows to build an engineering model for the spectrometer and to predict its main specifications taking into account the specificity of the MEMS technology used in the spectrometer fabrication.

  16. Wide band ENDOR spectrometer

    International Nuclear Information System (INIS)

    Mendonca Filho, C.

    1973-01-01

    The construction of an ENDOR spectrometer operating from 0,5 to 75 MHz within a single band, with ore Klystron and homodine detection, and no fundamental changes on the electron spin resonance spectrometer was described. The ENDOR signal can be detected both by amplitude modulation of the frequency field, or direct detection of the ESR output, which is taken to a signal analyser. The signal-to-noise ratio is raised by averaging rather than filtering avoiding the use of long time constants, providing natural line widths. The experimental apparatus and the spectra obtained are described. A discussion, relating the ENDOR line amplitudes with the experimental conditions is done and ENDOR mechanism, in which there is a relevant presence of cross relaxation is proposed

  17. FAST NEUTRON SPECTROMETER

    Science.gov (United States)

    Davis, F.J.; Hurst, G.S.; Reinhardt, P.W.

    1959-08-18

    An improved proton recoil spectrometer for determining the energy spectrum of a fast neutron beam is described. Instead of discriminating against and thereby"throwing away" the many recoil protons other than those traveling parallel to the neutron beam axis as do conventional spectrometers, this device utilizes protons scattered over a very wide solid angle. An ovoidal gas-filled recoil chamber is coated on the inside with a scintillator. The ovoidal shape of the sensitive portion of the wall defining the chamber conforms to the envelope of the range of the proton recoils from the radiator disposed within the chamber. A photomultiplier monitors the output of the scintillator, and a counter counts the pulses caused by protons of energy just sufficient to reach the scintillator.

  18. Mark III spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, D.; Bernstein, J.; Bunnell, K.; Burgueno, G.; Cassell, R.; Collins, B.; Coward, D.; Einsweiler, K.; Eisele, R.; Haber, B.

    1984-10-01

    This paper describes the design, construction and performance of the Mark III, a new general purpose large solid angle spectrometer at SPEAR, the SLAC 2-8 GeV e/sup +/e storage ring. The detector has been designed for the study of exclusive final states in e/sup +/e annihilation, which requires large solid angle coverage combined with charged particle momentum resolution, particle identification, and photon detection efficiency at low energies. (orig.).

  19. Mark III spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, D.; Bernstein, J.; Bunnell, K.; Burgueno, G.; Cassell, R.; Collins, B.; Coward, D.; Einsweiler, K.; Eisele, R.; Haber, B. (Stanford Linear Accelerator Center, CA (USA))

    1984-10-01

    This paper describes the design, construction and performance of the Mark III, a new general purpose large solid angle spectrometer at SPEAR, the SLAC 2-8 GeV e/sup +/e/sup -/ storage ring. The detector has been designed for the study of exclusive final states in e/sup +/e/sup -/ annihilation, which requires large solid angle coverage combined with charged particle momentum resolution, particle identification, and photon detection efficiency at low energies.

  20. Magnetic spectrometer control system

    International Nuclear Information System (INIS)

    Lecca, L.A.; Di Paolo, Hugo; Fernandez Niello, Jorge O.; Marti, Guillermo V; Pacheco, Alberto J.; Ramirez, Marcelo

    2003-01-01

    The design and implementation of a new computerized control system for the several devices of the magnetic spectrometer at TANDAR Laboratory is described. This system, as a main difference from the preexisting one, is compatible with almost any operating systems of wide spread use available in PC. This allows on-line measurement and control of all signals from any terminal of a computer network. (author)

  1. ALICE photon spectrometer crystals

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    Members of the mechanical assembly team insert the last few crystals into the first module of ALICE's photon spectrometer. These crystals are made from lead-tungstate, a crystal as clear as glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, emitting a flash of light allowing the energy of photons, electrons and positrons to be measured.

  2. Miniaturized Ion Mobility Spectrometer

    Science.gov (United States)

    Kaye, William J (Inventor); Stimac, Robert M. (Inventor)

    2017-01-01

    By utilizing the combination of a unique electronic ion injection control circuit in conjunction with a particularly designed drift cell construction, the instantly disclosed ion mobility spectrometer (IMS) achieves increased levels of sensitivity, while achieving significant reductions in size and weight. The instant IMS is of a much simpler and easy to manufacture design, rugged and hermetically sealed, capable of operation at high temperatures to at least 250 degrees Centigrade, and is uniquely sensitive, particularly to explosive chemicals.

  3. Current interruption transients calculation

    CERN Document Server

    Peelo, David F

    2014-01-01

    Provides an original, detailed and practical description of current interruption transients, origins, and the circuits involved, and how they can be calculated Current Interruption Transients Calculationis a comprehensive resource for the understanding, calculation and analysis of the transient recovery voltages (TRVs) and related re-ignition or re-striking transients associated with fault current interruption and the switching of inductive and capacitive load currents in circuits. This book provides an original, detailed and practical description of current interruption transients, origins,

  4. A spectrometer for the NSF

    International Nuclear Information System (INIS)

    Sanderson, N.E.

    1979-01-01

    It is shown that the capabilities of a magnetic spectrometer are needed to fully exploit the research programme involving charged particle detection to be carried out on the Nuclear Structure Facility (NSF) presently under construction at Daresbury. Performance requirements for such a spectrometer are examined indicating that the QMG/2 spectrometer of the Groningen type is very well suited to the high resolution work which will be possible using beams of light - heavy ions (A < 40). Consequently, and following the recommendations of the Magnetic Spectrometer Working Party, this spectrometer is to be installed at the NSF. (U.K.)

  5. Infrared absorption of gaseous ClCS detected with time-resolved Fourier-transform spectroscopy

    International Nuclear Information System (INIS)

    Chu, Li-Kang; Han, Hui-Ling; Lee, Yuan-Pern

    2007-01-01

    A transient infrared absorption spectrum of gaseous ClCS was detected with a step-scan Fourier-transform spectrometer coupled with a multipass absorption cell. ClCS was produced upon irradiating a flowing mixture of Cl 2 CS and N 2 or CO 2 with a KrF excimer laser at 248 nm. A transient band in the region of 1160-1220 cm -1 , which diminished on prolonged reaction, is assigned to the C-S stretching (ν 1 ) mode of ClCS. Calculations with density-functional theory (B3P86 and B3LYP/aug-cc-pVTZ) predict the geometry, vibrational wave numbers, and rotational parameters of ClCS. The rotational contour of the spectrum of ClCS simulated based on predicted rotational parameters agrees satisfactorily with experimental observation; from spectral simulation, the band origin is determined to be at 1194.4 cm -1 . Reaction kinetics involving ClCS, CS, and CS 2 are discussed

  6. Simultaneous Multi-Element Electrothermal Atomic Absorption ...

    African Journals Online (AJOL)

    NICO

    Simultaneous Multi-Element Electrothermal Atomic. Absorption Determination Using a Low Resolution CCD. Spectrometer and Continuum Light Source: The Concept and Methodology. Dimitri A. Katskov* and G. Eunice Khanye. Department of Chemistry and Physics, Tshwane University of Technology, Pretoria, 0001 South ...

  7. Accelerating field spectrometer for photons and electrons simultaneous measurement. Application to decay schemes study

    International Nuclear Information System (INIS)

    Busani, Jean.

    1982-09-01

    An original spectrometer was built to improve the measurement of the absolute emission intensities of radionuclides with converted low energy gamma transitions. In this spectrometer, the same Si(Li) detector simultaneously measures electrons and photons emitted by the studied radionuclide; an electrostatic field may be established between the source and the detector to modify the electrons energy. This field allows the electron and photon peaks to be separated, and the absorption and energy straggling by detector windows to be decreased. Special attention has been given to determine spectrometer efficiency calibration curves for electrons and photons. 147 Nd and 133 Ba were used to test the spectrometer improvement and the method used [fr

  8. Metrology for terahertz time-domain spectrometers

    Science.gov (United States)

    Molloy, John F.; Naftaly, Mira

    2015-12-01

    In recent years the terahertz time-domain spectrometer (THz TDS) [1] has emerged as a key measurement device for spectroscopic investigations in the frequency range of 0.1-5 THz. To date, almost every type of material has been studied using THz TDS, including semiconductors, ceramics, polymers, metal films, liquid crystals, glasses, pharmaceuticals, DNA molecules, proteins, gases, composites, foams, oils, and many others. Measurements with a TDS are made in the time domain; conversion from the time domain data to a frequency spectrum is achieved by applying the Fourier Transform, calculated numerically using the Fast Fourier Transform (FFT) algorithm. As in many other types of spectrometer, THz TDS requires that the sample data be referenced to similarly acquired data with no sample present. Unlike frequency-domain spectrometers which detect light intensity and measure absorption spectra, a TDS records both amplitude and phase information, and therefore yields both the absorption coefficient and the refractive index of the sample material. The analysis of the data from THz TDS relies on the assumptions that: a) the frequency scale is accurate; b) the measurement of THz field amplitude is linear; and c) that the presence of the sample does not affect the performance characteristics of the instrument. The frequency scale of a THz TDS is derived from the displacement of the delay line; via FFT, positioning errors may give rise to frequency errors that are difficult to quantify. The measurement of the field amplitude in a THz TDS is required to be linear with a dynamic range of the order of 10 000. And attention must be given to the sample positioning and handling in order to avoid sample-related errors.

  9. MASS SPECTROMETER LEAK

    Science.gov (United States)

    Shields, W.R.

    1960-10-18

    An improved valve is described for precisely regulating the flow of a sample fluid to be analyzed, such as in a mass spectrometer, where a gas sample is allowed to "leak" into an evacuated region at a very low, controlled rate. The flow regulating valve controls minute flow of gases by allowing the gas to diffuse between two mating surfaces. The structure of the valve is such as to prevent the corrosive feed gas from contacting the bellows which is employed in the operation of the valve, thus preventing deterioration of the bellows.

  10. Microwave absorption studies of MgB 2 superconductor

    Indian Academy of Sciences (India)

    Microwave absorption studies have been carried out on MgB2 superconductor using a standard X-band EPR spectrometer. The modulated low-field microwave absorption signals recorded for polycrystalline (grain size ∼ 10m) samples suggested the absence of weak-link character. The field dependent direct microwave ...

  11. Spectroscopy of transient neutral species via negative ion photoelectron spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, A.

    1991-12-01

    Negative ion photoelectron spectroscopy has been used to study two types of transient neutral species: bound free radicals (NO{sub 2} and NO{sub 3}) and unstable neutral species ((IHI) and (FH{sub 2})). The negative ion time-of-flight photoelectron spectrometer used for these experiments is described in detail.

  12. Spectroscopy of transient neutral species via negative ion photoelectron spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Alexandra [Univ. of California, Berkeley, CA (United States)

    1991-12-01

    Negative ion photoelectron spectroscopy has been used to study two types of transient neutral species: bound free radicals (NO2 and NO3) and unstable neutral species ([IHI] and [FH2]). The negative ion time-of-flight photoelectron spectrometer used for these experiments is described in detail.

  13. Chip scale broadly tunable laser for laser spectrometer

    Science.gov (United States)

    Chao, Tien-Hsin; Lu, Thomas; Davis, Scott R.; Anderson, Michael H.

    2016-04-01

    We are developing an innovative Tunable Laser Spectrometer (TLS) that is compact, broad tuning range (> 200 nm) enabled by an innovative chip-scale (a waveguide based architecture), non-mechanical (voltage- controlled tuning), Waveguide External-cavity Semiconductor Laser (WECSL). This WECSL based TLS, with broad tuning range, will enable the simultaneous measurement of multiple gases abundances in Martian and other planetary atmospheres, adsorbed to soil; and bound to rocks. This monolithic, robust, integrated-optic Tunable Laser Absorption Spectrometer (TLS) will operate in the near infrared and infrared spectral bands. The system architecture, principles of operation and applications of the TLS will be reported in this paper.

  14. Intramolecular charge transfer of 4-(dimethylamino)benzonitrile probed by time-resolved fluorescence and transient absorption: No evidence for two ICT states and a πσ* reaction intermediate

    International Nuclear Information System (INIS)

    Zachariasse, Klaas A.; Druzhinin, Sergey I.; Senyushkina, Tamara; Kovalenko, Sergey A.

    2009-01-01

    For the double exponential fluorescence decays of the locally excited (LE) and intramolecular charge transfer (ICT) states of 4-(dimethylamino)benzonitrile (DMABN) in acetonitrile (MeCN) the same times τ 1 and τ 2 are observed. This means that the reversible LE ICT reaction, starting from the initially excited LE state, can be adequately described by a two state mechanism. The most important factor responsible for the sometimes experimentally observed differences in the nanosecond decay time, with τ 1 (LE) 1 (ICT), is photoproduct formation. By employing a global analysis of the LE and ICT fluorescence response functions with a time resolution of 0.5 ps/channel in 1200 channels reliable kinetic and thermodynamic data can be obtained. The arguments presented in the literature in favor of a πσ* state with a bent CN group as an intermediate in the ICT reaction of DMABN are discussed. From the appearance of an excited state absorption (ESA) band in the spectral region between 700 and 800 nm in MeCN for N,N-dimethylanilines with CN, Br, F, CF 3 , and C(=O)OC 2 H 2 p-substituents, it is concluded that this ESA band cannot be attributed to a πσ * state, as only the C-C≡N group can undergo the required 120 deg. bending.

  15. The SPEDE electron spectrometer

    CERN Document Server

    O'Neill, George

    This thesis presents SPEDE (SPectrometer for Electron DEtection) and documents its construction, testing and performance during commissioning at Jyvaskyla, Finland, before deployment at the HIE-ISOLDE facility at CERN coupled with the MINIBALL array to perform in-beam electron-gamma spectroscopy using post-accelerated radioactive ion beams. Commissioning experiments took place in two two-day stints during spring 2015, coupled with several JUROGAMII gamma-detectors. This spectrometer will help aid in fully understanding exotic regions of the nuclear chart such as regions with a high degree of octupole deformation, and in those nuclei exhibiting shape coexistence. For the rst time, electron spectroscopy has been performed at the target position from states populated in accelerated nuclei via Coulomb excitation. The FWHM of SPEDE is approximately 7 keV at 320 keV, and Doppler correction was possible to improve Doppler broadened peaks. The results are intended to give the reader a full understanding of the dete...

  16. Prototype Neutron Energy Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Stephen Mitchell, Sanjoy Mukhopadhyay, Richard Maurer, Ronald Wolff

    2010-06-16

    The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production [ship effect], [a, n] reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

  17. A laboratory heterodyne emission spectrometer at submillimeter wavelengths.

    Science.gov (United States)

    Wehres, N; Maßen, J; Borisov, K; Schmidt, B; Lewen, F; Graf, U U; Honingh, C E; Higgins, D R; Schlemmer, S

    2018-02-21

    We present first results on a newly built broadband emission spectrometer for the laboratory making use of a double sideband (DSB) heterodyne receiver. The new spectrometer is perfectly suited for high-resolution emission spectroscopy of molecules of astrophysical importance. The current SIS receiver operates at RF frequencies between 270 and 390 GHz, coincident with Band 7 of the ALMA telescope. The instantaneous bandwidth is 5 GHz (DSB). In this work the full spectrometer and its components are described. Its performance, in particular its sensitivity, stability, reproducibility and systematic errors, is characterized in detail. For this purpose very broad band emission spectra of methyl cyanide have been recorded and compared to theoretical spectra. Isotopic variants are found in natural abundance and features attributed to vibrationally excited species are all recorded in the same spectrum. The performance of the new spectrometer is compared extensively to that of a traditional FM-absorption spectrometer and to recent versions of chirped-pulse spectrometers operated in the mm-wave regime. Further applications and future advancements of the current instrument are discussed.

  18. LADEE Neutral Mass Spectrometer Data

    Data.gov (United States)

    National Aeronautics and Space Administration — This bundle contains the data collected by the Neutral Mass Spectrometer (NMS) instrument aboard the Lunar Atmosphere and Dust Environment Explorer (LADEE)...

  19. PSH Transient Simulation Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-12-21

    PSH Transient Simulation Modeling presentation from the WPTO FY14 - FY16 Peer Review. Transient effects are an important consideration when designing a PSH system, yet numerical techniques for hydraulic transient analysis still need improvements for adjustable-speed (AS) reversible pump-turbine applications.

  20. Ultra-Wideband Optical Modulation Spectrometer (OMS) Development

    Science.gov (United States)

    Gardner, Jonathan (Technical Monitor); Tolls, Volker

    2004-01-01

    The optical modulation spectrometer (OMS) is a novel, highly efficient, low mass backend for heterodyne receiver systems. Current and future heterodyne receiver systems operating at frequencies up to a few THz require broadband spectrometer backends to achieve spectral resolutions of R approximately 10(exp 5) to 10(exp 6) to carry out many important astronomical investigations. Among these are observations of broad emission and absorption lines from extra-galactic objects at high redshifts, spectral line surveys, and observations of planetary atmospheres. Many of these lines are pressure or velocity broadened with either large half-widths or line wings extending over several GHz. Current backend systems can cover the needed bandwidth only by combining the output of several spectrometers, each with typically up to 1 GHz bandwidth, or by combining several frequency-shifted spectra taken with a single spectrometer. An ultra-wideband optical modulation spectrometer with 10 - 40 GHz bandwidth will enable broadband ob- servations without the limitations and disadvantages of hybrid spectrometers. Spectrometers like the OMS will be important for both ground-based observatories and future space missions like the Single Aperture Far-Infrared Telescope (SAFIR) which might carry IR/submm array heterodyne receiver systems requiring a spectrometer for each array pixel. Small size, low mass and small power consumption are extremely important for space missions. This report summarizes the specifications developed for the OMS and lists already identified commercial parts. The report starts with a review of the principle of operation, then describes the most important components and their specifications which were derived from theory, and finishes with a conclusion and outlook.

  1. Demonstration That Calibration of the Instrument Response to Polarizations Parallel and Perpendicular to the Object Space Projected Slit of an Imaging Spectrometer Enable Measurement of the Atmospheric Absorption Spectrum in Region of the Weak CO2 Band for the Case of Arbitrary Polarization: Implication for the Geocarb Mission

    Science.gov (United States)

    Kumer, J. B.; Rairden, R. L.; Polonsky, I. N.; O'Brien, D. M.

    2014-12-01

    The Tropospheric Infrared Mapping Spectrometer (TIMS) unit rebuilt to operate in a narrow spectral region, approximately 1603 to 1615 nm, of the weak CO2 band as described by Kumer et al. (2013, Proc. SPIE 8867, doi:10.1117/12.2022668) was used to conduct the demonstration. An integrating sphere (IS), linear polarizers and quarter wave plate were used to confirm that the instrument's spectral response to unpolarized light, to 45° linearly polarized light and to circular polarized light are identical. In all these cases the intensity components Ip = Is where Ip is the component parallel to the object space projected slit and Is is perpendicular to the slit. In the circular polarized case Ip = Is in the time averaged sense. The polarizer and IS were used to characterize the ratio Rθ of the instrument response to linearly polarized light at the angle θ relative to parallel from the slit, for increments of θ from 0 to 90°, to that of the unpolarized case. Spectra of diffusely reflected sunlight passed through the polarizer in increments of θ, and divided by the respective Rθ showed identical results, within the noise limit, for solar spectrum multiplied by the atmospheric transmission and convolved by the Instrument Line Shape (ILS). These measurements demonstrate that unknown polarization in the diffusely reflected sunlight on this small spectral range affect only the slow change across the narrow band in spectral response relative to that of unpolarized light and NOT the finely structured / high contrast spectral structure of the CO2 atmospheric absorption that is used to retrieve the atmospheric content of CO2. The latter is one of the geoCARB mission objectives (Kumer et al, 2013). The situation is similar for the other three narrow geoCARB bands; O2 A band 757.9 to 768.6 nm; strong CO2 band 2045.0 to 2085.0 nm; CH4 and CO region 2300.6 to 2345.6 nm. Polonsky et al have repeated the mission simulation study doi:10.5194/amt-7-959-2014 assuming no use of a geo

  2. The nanopore mass spectrometer

    Science.gov (United States)

    Bush, Joseph; Maulbetsch, William; Lepoitevin, Mathilde; Wiener, Benjamin; Mihovilovic Skanata, Mirna; Moon, Wooyoung; Pruitt, Cole; Stein, Derek

    2017-11-01

    We report the design of a mass spectrometer featuring an ion source that delivers ions directly into high vacuum from liquid inside a capillary with a sub-micrometer-diameter tip. The surface tension of water and formamide is sufficient to maintain a stable interface with high vacuum at the tip, and the gas load from the interface is negligible, even during electrospray. These conditions lifted the usual requirement of a differentially pumped system. The absence of a background gas also opened up the possibility of designing ion optics to collect and focus ions in order to achieve high overall transmission and detection efficiencies. We describe the operation and performance of the instrument and present mass spectra from solutions of salt ions and DNA bases in formamide and salt ions in water. The spectra show singly charged solute ions clustered with a small number of solvent molecules.

  3. BNL multiparticle spectrometer software

    International Nuclear Information System (INIS)

    Saulys, A.C.

    1984-01-01

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the program controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both on-line and off-line operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed

  4. A Moessbauer effect spectrometer

    International Nuclear Information System (INIS)

    Fayek, M.K.; Abbas, Y.M.; Bahgat, A.A.

    1983-01-01

    A Moessbauer effect spectrometer of Harwell type is installed and put in operation. The driving system is of a constant acceleration mode with a velocity range 40mm/sec. and associated to a 1024 multichannel analyser working in a multiscalar time mode. The gamma ray sources are 50 mCi Co 57 in Pd and 20 mCi Snsup(119m) in Ba Sn(O) 3 . Measurements are taken with the source kept at room temperature, while the absorber can be maintained at various temperatures. Gamma ray resonance spectra of different standard samples are obtained. Zero velocity and magnetic field calibration curves are deduced. Examples of some Moessbauer spectra for running investigated materials with a comprehensive general description are also given

  5. The Philippine spectrometer

    International Nuclear Information System (INIS)

    Juliano, J.O.

    1965-01-01

    A notable project for international collaboration, in which participants from Indonesia, Korea, Thailand, China and the Philippines are working together, has been launched in the Philippines with Indian assistance under the aegis of the Agency. This is a regional training and research programme using a neutron crystal spectrometer, which has been established since January 1965 at the Philippine Atomic Research Centre in Diliman, Quezon City, Philippines. It is called the IPA Project after the signatories to a five year trilateral agreement, namely, the Government of India,the Republic of the Philippines, and the International Atomic Energy Agency. The programme is administered by a Joint Committee composed of one representative each of the Philippines, India and the Agency. The objective of this cooperative venture is to establish a research centre on neutron diffraction in which scientists and technicians from any Member State of IAEA in South Asia, South-East Asia and Pacific, or Far East regions could come to participate in research and training. Studies in solid state physics, such a s the structure determination of alloys and organic crystals, studies on the orientation of magnetic moments in the lattice of magnetic substances, and other problems based on elastic and inelastic scattering of neutrons are undertaken. There are a number of research reactors in this region where neutron spectrometers can be utilized and the recent establishment of this cooperative international research and training programme has been a timely one for this area of the world. Indeed, a number of other countries have shown a strong growing interest in the development of the project

  6. Magnetic quadrupole and solenoidal spectrometers

    International Nuclear Information System (INIS)

    Laurent, H.; Schapira, J.P.

    1979-01-01

    General optical properties of magnetic quadrupole spectrometers are reviewed, together with experimental purposes for nuclear physics: background reduction, magnetic rigidity filtering for extreme forward angles measurements, light charged particle discrimination, ionic charge state separation, time of flight mass spectrometry and fast collection of radioactive nuclear reaction products. Possibility of alternative devices such as superconducting quadrupoles or solenoid spectrometers are discussed. (Auth.)

  7. The ALICE forward muon spectrometer

    Indian Academy of Sciences (India)

    ICE detector will allow to identify the quarkonium states through both the dielectron and the dimuon channels. For this purpose the apparatus is equipped with a transition radiation detector in its central part and with a forward muon spectrometer at small angles. After a brief description of the forward muon spectrometer, ...

  8. ATF beamline 1 analysis spectrometer

    International Nuclear Information System (INIS)

    Fernow, R.C.; Kirk, H.G.; Ulc, S.

    1993-01-01

    We describe the design parameters and expected performance of the analysis spectrometer for beamline 1 at the BNL Accelerator Test Facility. The spectrometer should be well suited for measuring the change in energy caused by the first generation laser acceleration experiments

  9. Development of near infrared spectrometer for gem materials study

    Science.gov (United States)

    Jindata, W.; Meesiri, W.; Wongkokua, W.

    2015-07-01

    Most of gem materials can be characterized by infrared absorption spectroscopy. Normally, mid infrared absorption technique has been applied for investigating fundamental vibrational modes. However, for some gem materials, such as tourmaline, NIR is a better choice due to differentiation. Most commercial NIR spectrometers employ complicated dispersive grating or Fourier transform techniques. In this work, we developed a filter type NIR spectrometer with the availability of high efficiency and low-cost narrow bandpass NIR interference filters to be taught in a physics laboratory. The instrument was designed for transmission-mode configuration. A 50W halogen lamp was used as NIR source. There were fourteen NIR filters mounted on a rotatory wheel for wavelength selection ranging from 1000-1650 nm with steps of 50 nm. A 1.0 mm diameter of InGaAs photodiode was used as the detector for the spectrometer. Hence, transparent gem materials can be used as samples for experiment. Student can learn vibrational absorption spectroscopy as well as Beer-Lambert law from the development of this instrument.

  10. Neutron range spectrometer

    Science.gov (United States)

    Manglos, Stephen H.

    1989-06-06

    A neutron range spectrometer and method for determining the neutron energy spectrum of a neutron emitting source are disclosed. Neutrons from the source are collimnated along a collimation axis and a position sensitive neutron counter is disposed in the path of the collimated neutron beam. The counter determines positions along the collimation axis of interactions between the neutrons in the neutron beam and a neutron-absorbing material in the counter. From the interaction positions, a computer analyzes the data and determines the neutron energy spectrum of the neutron beam. The counter is preferably shielded and a suitable neutron-absorbing material is He-3. The computer solves the following equation in the analysis: ##EQU1## where: N(x).DELTA.x=the number of neutron interactions measured between a position x and x+.DELTA.x, A.sub.i (E.sub.i).DELTA.E.sub.i =the number of incident neutrons with energy between E.sub.i and E.sub.i +.DELTA.E.sub.i, and C=C(E.sub.i)=N .sigma.(E.sub.i) where N=the number density of absorbing atoms in the position sensitive counter means and .sigma. (E.sub.i)=the average cross section of the absorbing interaction between E.sub.i and E.sub.i +.DELTA.E.sub.i.

  11. UCN gravitational spectrometer

    International Nuclear Information System (INIS)

    Kawabata, Yuji

    1988-01-01

    Concept design is carried out of two types of ultra cold neutron scallering equipment using the fall-focusing principle. One of the systems comprises a vertical gravitational spectrometer and the other includes a horizontal gravitation analyzer. A study is made of their performance and the following results are obtained. Fall-focusing type ultra cold neutron scattering equipment can achieve a high accuracy for measurement of energy and momentum. Compared with conventional neutron scattering systems, this type of equipment can use neutron very efficiently because scattered neutrons within a larger solid angle can be used. The maximum solid angle is nearly 4π and 2π for the vertical and horizontal type, respectively. Another feature is that the size of equipment can be reduced. In the present concept design, the equipment is spherical with a diameter of about 1 m, as compared with NESSIE which is 6.7 m in length and 4.85 m in height with about the same accuracy. Two horizontal analyzers and a vertical spectroscope are proposed. They are suitable for angle-dependent non-elastic scattering in the neutron velocity range of 6∼15 m/s, pure elastic scattering in the range of 4∼7 m/s, or angle-integration non-elastic scattering in the range of 4∼15 m/s. (N.K.)

  12. Respiratory mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mostert, J.W. (Pretoria Univ. (South Africa). Dept. of Anesthesiology)

    1983-06-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M/sup 2/ body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O/sub 2/ consumption of less than 50 ml O/sub 2//min/M/sup 2/) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery.

  13. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can "instantaneously"...

  14. Hyper-filter-fluorescer spectrometer for fusion x-ray diagnostics

    International Nuclear Information System (INIS)

    Wang, C.L.

    1981-01-01

    The filter-fluorescer spectrometer (FFS) is a powerful tool for measuring x-ray spectrum from high fluence x-ray sources. However, this technique is limited to energies less than 120 keV, because there are no practical absorption edges available above this energy. In this paper, we present a new method of utilizing the filter-fluorescer system for x-ray spectral measurement above 120 keV. The new apparatus is called hyper-filter-fluorescer spectrometer

  15. Elements of Tiny Plasma Spectrometers

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to advance major elements of a miniaturized plasma spectrometer for flight on future missions. This type of instrument has been developed and successfully...

  16. Moessbauer spectrometer on integrated circuits

    International Nuclear Information System (INIS)

    Tomov, T.; Spasov, A.; Kunov, B.

    1978-01-01

    Two versions of the small-size high-quality Moessbauer spectrometer for 57 Fe spectroscopy are developed. The first version includes a proportion counter, a preamplifier, a one-chennel analyzer, a timer, and a scaler. The spectrometer is intended for measuring characteristic points of the Moessbauer-spectra and operates at constant velocities. The spectrometer parameters are as follows: integral non-linearity of the entire channel about 1%, maximum load for 14 keV line 8x10 4 pulse/s. The second version uses a multichannel time analyzer as a recording device. The spectrometer operates in the saw-toothed velocity modulation, the integral nonlinearity of the modulation being at least 0.1%

  17. Miniaturized Waveguide Fourier Transform Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — To demonstrate the efficacy of a spectrometer-on-chip system for in-situ and remote monitoring of planetary atmospheric and surface chemistry, physics, and surface...

  18. Versatile central spectrometer for ISABELLE

    International Nuclear Information System (INIS)

    Cheng, D.; Goulianso, K.; Knapp, B.; Rosen, J.; Schlein, P.

    1975-01-01

    A large aperture magnetic spectrometer is proposed to study hadrons and leptons produced in the central region at Isabelle. The essential element of the spectrometer is a large double-dipole magnet system with common flux return straddling the intersection region. The air gaps provide magnetic analysis of charged particle for up to 50 percent of the azimuthal angular range. Drift chambers, Cherenkov counters and shower detectors positioned on both sides of the beam lines comprise two spectrometers for analysis of hadrons and electrons. Muons can be momentum analyzed over a large fraction at the azimuthal angle by utilizing the upper and lower sections on the magnet yoke to provide hadron filtering and magnetic deflection. Cylindrical chambers around the vacuum pipe provide multiplicity information for events of interest. The proposed magnet configuration allows unobscured coverage of smaller angle particles with the addition of septum magnet spectrometers downstream of the central magnet in both arms.

  19. Portable Remote Imaging Spectrometer (PRISM)

    Data.gov (United States)

    National Aeronautics and Space Administration — Develop an UV-NIR (350nm to 1050 nm) portable remote imaging spectrometer (PRISM) for flight on a variety of airborne platforms with high SNR and response uniformity...

  20. Electron spectrometers with internal conversion

    International Nuclear Information System (INIS)

    Suita, J.C.; Lemos Junior, O.F.; Auler, L.T.; Silva, A.G. da

    1981-01-01

    The efforts that the Department of Physics (DEFI) of Institute of Nuclear Engineering (IEN) are being made aiming at adjusting the electron spectrometers with internal conversion to its necessity, are shown. (E.G.) [pt

  1. Spectroscopic classification of transients

    DEFF Research Database (Denmark)

    Stritzinger, M. D.; Fraser, M.; Hummelmose, N. N.

    2017-01-01

    We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017.......We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017....

  2. Fluid dynamic transient analysis

    International Nuclear Information System (INIS)

    Vilhena Reigosa, R. de

    1992-01-01

    This paper describes the methodology adopted at NUCLEN for the fluid dynamic analyses for ANGRA 2. The fluid dynamic analysis allows, through computer codes to simulate and quantify the loads resulting from fluid dynamic transients caused by postulated ruptures or operational transients, in the piping of the safety systems and of the important operational systems. (author)

  3. BIS-2 spectrometer for search and for investigation of narrow resonances

    International Nuclear Information System (INIS)

    Aleev, A.N.; Aref'ev, V.A.; Balandin, V.P.

    1991-01-01

    Configuration and main characteristics of the BIS-2 filmless spectrometer designed for search and study of charmed particles and narrow resonances generated in neutron-nuclear interactions are described. The spectrometer was arranged in neutral beam of the Serpukhov accelerator. Mean neutron energy is about 40 GeV. Main parts of the spectrometer are: spectrometric magnet, system of proportional chambers, system of charged particle identification, Cherenkov total-absorption spectrometer, system of scintillation counters, electronic equipment for event selection and data recording. The calculated and measured characteristics of separate parts and the system as a whole, as well as review of main results obtained by means of the BIS-2 spectrometer are given

  4. Uric acid detection using uv-vis spectrometer

    Science.gov (United States)

    Norazmi, N.; Rasad, Z. R. Abdul; Mohamad, M.; Manap, H.

    2017-10-01

    The aim of this research is to detect uric acid (UA) concentration using Ultraviolet-Visible (UV-Vis) spectrometer in the Ultraviolet (UV) region. Absorption technique was proposed to detect different uric acid concentrations and its UV absorption wavelength. Current practices commonly take a lot of times or require complicated structures for the detection process. By this proposed spectroscopic technique, every concentration can be detected and interpreted into an absorbance value at a constant wavelength peak in the UV region. This is due to the chemical characteristics belong to the uric acid since it has a particular absorption cross-section, σ which can be calculated using Beer’s Lambert law formula. The detection performance was displayed using Spectrasuite sofware. It showed fast time response about 3 seconds. The experiment proved that the concentrations of uric acid were successfully detected using UV-Vis spectrometer at a constant absorption UV wavelength, 294.46 nm in a low time response. Even by an artificial sample of uric acid, it successfully displayed a close value as the ones reported with the use of the medical sample. It is applicable in the medical field and can be implemented in the future for earlier detection of abnormal concentration of uric acid.

  5. Coastal Research Imaging Spectrometer

    Science.gov (United States)

    Lucey, Paul G.; Williams, Timothy; Horton, Keith A.

    2004-01-01

    The Coastal Research Imaging Spectrometer (CRIS) is an airborne remote sensing system designed specifically for research on the physical, chemical, and biological characteristics of coastal waters. The CRIS includes a visible-light hyperspectral imaging subsystem for measuring the color of water, which contains information on the biota, sediment, and nutrient contents of the water. The CRIS also includes an infrared imaging subsystem, which provides information on the temperature of the water. The combination of measurements enables investigation of biological effects of both natural and artificial flows of water from land into the ocean, including diffuse and point-source flows that may contain biological and/or chemical pollutants. Temperature is an important element of such measurements because temperature contrasts can often be used to distinguish among flows from different sources: for example, a sewage outflow could manifest itself in spectral images as a local high-temperature anomaly. Both the visible and infrared subsystems scan in pushbroom mode: that is, an aircraft carrying the system moves along a ground track, the system is aimed downward, and image data are acquired in across-track linear arrays of pixels. Both subsystems operate at a frame rate of 30 Hz. The infrared and visible-light optics are adjusted so that both subsystems are aimed at the same moving swath, which has across-track angular width of 15 . Data from the infrared and visible imaging subsystems are stored in the same file along with aircraft- position data acquired by a Global Positioning System receiver. The combination of the three sets of data is used to construct infrared and hyperspectral maps of scanned areas (see figure). The visible subsystem is based on a grating spectrograph and a rapid-readout charge-coupled-device camera. Images of the swatch are acquired in 256 spectral bands at wavelengths from 400 to 800 nm. The infrared subsystem, which is sensitive in a single

  6. Infrared laser transient absorption spectroscopy of the ethyl radical

    International Nuclear Information System (INIS)

    Sears, T.J.; Johnson, P.M.; Jin, P.; Oatis, S.

    1996-01-01

    The observation and analysis of the high resolution spectrum of the CH 2 rocking fundamental of the ethyl radical, C 2 H 5 , at wavelengths close to 18.9 μm is reported. The band origin is found to be at 528.1 cm -1 . The spectrum shows evidence for a very low barrier to internal rotation, or torsion, in this species. A simple model Hamiltonian, based on an assumed structure with G 12 symmetry, qualitatively reproduces the observations and implies a torsional barrier of approximately 20 cm -1 in both the zero point and excited vibrational states. The Hamiltonian cannot reproduce the observations to the level of the experimental accuracy and the importance of several neglected terms is tested and discussed. The observed torsional splittings imply that, within the confines of the model, the a-inertial and internal rotation axes in the molecule are coincident to within 1 degree. In addition to their intrinsic interest, the spectra will be useful for future state resolved studies of the kinetics of chemical reactions involving the radical. copyright 1996 American Institute of Physics

  7. Inelastic electron scattering spectroscopy: a comparison of absorption and emission spectra

    International Nuclear Information System (INIS)

    Schnatterly, S.E.

    1984-01-01

    The operation of a high energy inelastic scattering spectrometer is briefly described. Measured absorption and emission spectra are fit to parameters in recently described models for insulators. Implications for model validity are discussed

  8. ps-TRIR covers all the bases--recent advances in the use of transient IR for the detection of short-lived species in nucleic acids.

    Science.gov (United States)

    Towrie, Michael; Doorley, Gerard W; George, Michael W; Parker, Anthony W; Quinn, Susan J; Kelly, John M

    2009-07-01

    Recent developments of the picosecond transient absorption infrared technique and its ability to elucidate the nature and kinetic behaviour of transient species formed upon pulsed laser excitation of nucleic acids are described.

  9. Summary of transient management

    International Nuclear Information System (INIS)

    Sheron, B.W.

    1984-01-01

    This chapter reviews the papers on evaluating and managing transients, as given at the American Nuclear Society Topical Meeting on Anticipated and Abnormal Plant Transients in Light Water Reactors. Transient management involves both diverse and related areas such as analysis, systems performance, human performance, procedures, and training. State-of-the-art simulators are being improved to solve the constitutive equations for two-phase fluid flow by the development of a new generation of analysis codes which are simpler and faster than earlier codes. Both the US NRC and the nuclear industry are criticized for solving problems by adding additional requirements for the reactor operator rather than by recognizing design deficiencies

  10. Gas identification field test based on FTIR imaging spectrometer

    Science.gov (United States)

    Wang, Chensheng; Liu, Xingchao; Zhang, Zhijie; Yu, Hui

    2017-10-01

    Gas detection and identification is based on the spectral absorption peak feature, which is acquired by the spectrometer. FTIR imaging spectrometer has the advantages of high spectral resolution and good sensitivity, which are both suitable for the unknown or mixture gas identification applications, such as plume pollution monitoring, chemical agents detection and leakage detection. According to the application requirement, a dual band FTIR imaging spectrometer has been developed and verified. This FTIR imaging spectrometer combines the infrared thermal imaging sensor and Michelson interferometer to form the three dimensional data cube. Based on this instrument, the theoretical analysis and algorithm is introduced, and the numerical method is explained to illuminate the basic idea in gas identification based on spectral features. After that, the field verification test is setup and completed. Firstly, the FTIR imaging spectrometer is used to detect SF6, NH3 and the mixture gas, while the gas is exhausted out from the storage vase with a specific speed. Secondly, the instrument is delivered to the industrial area to monitor the plume emission, and analyze the components in plume. Finally, the instrument is utilized to monitoring the oil spill in ocean, and the practical maritime trial is realized. Further, the gas concentration evaluation method is discussed. Quantitative issue in gas identification is an important topic. The test results show that, based on the gas identification method introduced in this paper, FTIR imaging spectrometer can be utilized to identify the unknown gas or mixture gas in real time. The instrument will play a key role in environmental emergency and monitoring application.

  11. Spectrometers for compact neutron sources

    Science.gov (United States)

    Voigt, J.; Böhm, S.; Dabruck, J. P.; Rücker, U.; Gutberlet, T.; Brückel, T.

    2018-03-01

    We discuss the potential for neutron spectrometers at novel accelerator driven compact neutron sources. Such a High Brilliance Source (HBS) relies on low energy nuclear reactions, which enable cryogenic moderators in very close proximity to the target and neutron optics at comparably short distances from the moderator compared to existing sources. While the first effect aims at increasing the phase space density of a moderator, the second allows the extraction of a large phase space volume, which is typically requested for spectrometer applications. We find that competitive spectrometers can be realized if (a) the neutron production rate can be synchronized with the experiment repetition rate and (b) the emission characteristics of the moderator can be matched to the phase space requirements of the experiment. MCNP simulations for protons or deuterons on a Beryllium target with a suitable target/moderator design yield a source brightness, from which we calculate the sample fluxes by phase space considerations for different types of spectrometers. These match closely the figures of todays spectrometers at medium flux sources. Hence we conclude that compact neutron sources might be a viable option for next generation neutron sources.

  12. Inverse-magnetron mass spectrometer

    International Nuclear Information System (INIS)

    Pakulin, V.N.

    1979-01-01

    Considered is the operation of a typical magnetron mass spectrometer with an internal ion source and that of an inverse magnetron mass spectrometer with an external ion source. It is found that for discrimination of the same mass using the inverse design of mass spectrometers it is possible to employ either r 2 /r 1 times lesser magnetic fields at equal accelerating source-collector voltages, or r 2 /r 1 higher accelerating voltages at equal magnetic fields, as compared to the typical design (r 1 and r 2 being radii of the internal and external electrodes of the analyser, respectively). The design of an inverse-magnetron mass spectrometer is described. The mass analyzer is formed by a cylindrical electrode of 3 mm diameter and a coaxial tubular cylinder of 55 mm diameter. External to the analyzer is an ionizing chamber at the pressure of up to 5x10 -6 torr. The magnetic field along the chamber axis produced by a solenoid was 300 Oe. At the accelerating voltage of 100 V and mass 28, the spectrometer has a resolution of 30 at a half-peak height

  13. Transient Ischemic Attack

    Medline Plus

    Full Text Available ... Ischemic Attack TIA , or transient ischemic attack, is a "mini stroke" that occurs when a blood clot blocks an artery for a short time. The only difference between a stroke ...

  14. Transient Ischemic Attack

    Medline Plus

    Full Text Available ... TIA , or transient ischemic attack, is a "mini stroke" that occurs when a blood clot blocks an ... a short time. The only difference between a stroke and TIA is that with TIA the blockage ...

  15. A high resolution, low background fast neutron spectrometer

    CERN Document Server

    Abdurashitov, J N; Kalikhov, A V; Matushko, V L; Shikhin, A A; Yants, V E; Zaborskaia, O S; Adams, J M; Nico, J S; Thompson, A K

    2002-01-01

    We discuss the possibility to create a spectrometer of full absorption based on liquid scintillator doped with enriched sup 6 Li. Of specific interest, the spectrometer will have energy resolution estimated to lie in the range 5-10% for 14 MeV neutrons. It will be sensitive to fluxes from 10 sup - sup 4 to 10 sup 6 cm sup - sup 2 s sup - sup 1 above a threshold of 1 MeV in a gamma-background of up to 10 sup 4 s sup - sup 1. The detector's efficiency will be determined by the volume of the scintillator only (approx 3 l) and is estimated to be 0.2-10%. The main reason for the poor resolution of an organic scintillator based spectrometer of full absorption is a non-linear light-yield of the scintillator for recoil protons. The neutron energy is occasionally distributed among recoil protons, and due to non-linear light-yield the total amount of light from all recoil protons ambiguously determines the initial neutron energy. The high-energy resolution will be achieved by compensation of the non-linear light-yield ...

  16. Evaluation of the ROTAX spectrometer

    International Nuclear Information System (INIS)

    Tietze-Jaensch, H.; Schmidt, W.; Geick, R.

    1997-01-01

    After installation of the new-type rotating crystal analyser spectrometer ROTAX at ISIS, we report on practical experience and describe its current status. The rotating analyser technique works feasibly and reliably and provides an ultimate scan flexibility on a pulsed time-of-flight neutron spectrometer. The spinning analyser achieves a mulitplex advantage factor of ca. 50 without compromising the resolution of the instrument. Despite these instrument merits its individual beam position at ISIS has only an unsatisfactorily weak flux, thus hindering this instrument yet to become fully competitive with other high-performance neutron spectrometers based at high-flux reactors. However, we strongly recommend a ROTAX-type instrument to be emphasized when the instrumentation suite of the future European spallation source ESS will come under scrutiny. (orig.)

  17. How to Design a Spectrometer.

    Science.gov (United States)

    Scheeline, Alexander

    2017-10-01

    Designing a spectrometer requires knowledge of the problem to be solved, the molecules whose properties will contribute to a solution of that problem and skill in many subfields of science and engineering. A seemingly simple problem, design of an ultraviolet, visible, and near-infrared spectrometer, is used to show the reasoning behind the trade-offs in instrument design. Rather than reporting a fully optimized instrument, the Yin and Yang of design choices, leading to decisions about financial cost, materials choice, resolution, throughput, aperture, and layout are described. To limit scope, aspects such as grating blaze, electronics design, and light sources are not presented. The review illustrates the mixture of mathematical rigor, rule of thumb, esthetics, and availability of components that contribute to the art of spectrometer design.

  18. Interfacing an aspiration ion mobility spectrometer to a triple quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Adamov, Alexey; Viidanoja, Jyrki; Kaerpaenoja, Esko; Paakkanen, Heikki; Ketola, Raimo A.; Kostiainen, Risto; Sysoev, Alexey; Kotiaho, Tapio

    2007-01-01

    This article presents the combination of an aspiration-type ion mobility spectrometer with a mass spectrometer. The interface between the aspiration ion mobility spectrometer and the mass spectrometer was designed to allow for quick mounting of the aspiration ion mobility spectrometer onto a Sciex API-300 triple quadrupole mass spectrometer. The developed instrumentation is used for gathering fundamental information on aspiration ion mobility spectrometry. Performance of the instrument is demonstrated using 2,6-di-tert-butyl pyridine and dimethyl methylphosphonate

  19. Temperature dependence of the HNO3 UV absorption cross sections

    Science.gov (United States)

    Burkholder, James B.; Talukdar, Ranajit K.; Ravishankara, A. R.; Solomon, Susan

    1993-01-01

    The temperature dependence of the HNO3 absorption cross sections between 240 and 360 K over the wavelength range 195 to 350 nm has been measured using a diode array spectrometer. Absorption cross sections were determined using both (1) absolute pressure measurements at 298 K and (2) a dual absorption cell arrangement in which the absorption spectrum at various temperatures is measured relative to the room temperature absorption spectrum. The HNO3 absorption spectrum showed a temperature dependence which is weak at short wavelengths but stronger at longer wavelengths which are important for photolysis in the lower stratosphere. The 298 K absorption cross sections were found to be larger than the values currently recommended for atmospheric modeling (DeMore et al., 1992). Our absorption cross section data are critically compared with the previous measurements of both room temperature and temperature-dependent absorption cross sections. Temperature-dependent absorption cross sections of HNO3 are recommended for use in atmospheric modeling. These temperature dependent HNO3 absorption cross sections were used in a two-dimensional dynamical-photochemical model to demonstrate the effects of the revised absorption cross sections on loss rate of HNO3 and the abundance of NO2 in the stratosphere.

  20. Microwave absorption studies of MgB2 superconductor

    Indian Academy of Sciences (India)

    band (9–. 10 GHz) spectrometer. Both polycrystalline pellet and single-grain MgB2, having nearly the same Tc (∼ 39 K) and same size (3×2×1 mm3), were used in the present investigations. Low field modulated microwave absorption signals ...

  1. Microwave absorption studies of MgB 2 superconductor

    Indian Academy of Sciences (India)

    Microwave absorption studies have been carried out on MgB2 superconductor using a standard X-band EPR spectrometer. ... Radiochemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085, India; Technical Physics and Prototype Engineering Division, Bhabha Atomic Research Centre, Mumbai 400 085, India ...

  2. Transient charging and discharging current study in pure PVF and ...

    Indian Academy of Sciences (India)

    Keywords. PVF; PVDF; polyblend; fluoropolymers; transient current. 1. Introduction. If we take a polymer and apply a step field to it, the field interacts with the bound and free charges causing current flow in the external circuit. Generally, this current, known as absorption or charging current, depends on the time elapsed.

  3. Aerosol Absorption Measurements in MILAGRO.

    Science.gov (United States)

    Gaffney, J. S.; Marley, N. A.; Arnott, W. P.; Paredes-Miranda, L.; Barnard, J. C.

    2007-12-01

    During the month of March 2006, a number of instruments were used to determine the absorption characteristics of aerosols found in the Mexico City Megacity and nearby Valley of Mexico. These measurements were taken as part of the Department of Energy's Megacity Aerosol Experiment - Mexico City (MAX-Mex) that was carried out in collaboration with the Megacity Interactions: Local and Global Research Observations (MILAGRO) campaign. MILAGRO was a joint effort between the DOE, NSF, NASA, and Mexican agencies aimed at understanding the impacts of a megacity on the urban and regional scale. A super-site was operated at the Instituto Mexicano de Petroleo in Mexico City (designated T-0) and at the Universidad Technologica de Tecamac (designated T-1) that was located about 35 km to the north east of the T-0 site in the State of Mexico. A third site was located at a private rancho in the State of Hidalgo approximately another 35 km to the northeast (designated T-2). Aerosol absorption measurements were taken in real time using a number of instruments at the T-0 and T-1 sites. These included a seven wavelength aethalometer, a multi-angle absorption photometer (MAAP), and a photo-acoustic spectrometer. Aerosol absorption was also derived from spectral radiometers including a multi-filter rotating band spectral radiometer (MFRSR). The results clearly indicate that there is significant aerosol absorption by the aerosols in the Mexico City megacity region. The absorption can lead to single scattering albedo reduction leading to values below 0.5 under some circumstances. The absorption is also found to deviate from that expected for a "well-behaved" soot anticipated from diesel engine emissions, i.e. from a simple 1/lambda wavelength dependence for absorption. Indeed, enhanced absorption is seen in the region of 300-450 nm in many cases, particularly in the afternoon periods indicating that secondary organic aerosols are contributing to the aerosol absorption. This is likely due

  4. A Simple, Student-Built Spectrometer to Explore Infrared Radiation and Greenhouse Gases

    Science.gov (United States)

    Bruce, Mitchell R. M.; Wilson, Tiffany A.; Bruce, Alice E.; Bessey, S. Max; Flood, Virginia J.

    2016-01-01

    In this experiment, students build a spectrometer to explore infrared radiation and greenhouse gases in an inquiry-based investigation to introduce climate science in a general chemistry lab course. The lab is based on the exploration of the thermal effects of molecular absorption of infrared radiation by greenhouse and non-greenhouse gases. A…

  5. Compact Spectrometers Based on Linear Variable Filters

    Data.gov (United States)

    National Aeronautics and Space Administration — Demonstrate a linear-variable spectrometer with an H2RG array. Linear Variable Filter (LVF) spectrometers provide attractive resource benefits – high optical...

  6. The transient reaction characteristic of piperonal and anthraquinone derivative: a pulse radiolytic study

    International Nuclear Information System (INIS)

    Ma Jianhua; Lin Weizhen; Wang Wenfeng; Yao Side

    2006-01-01

    Piperonal belongs to naturally organic compound and anthraquinone-2-sulfate is a important anthraquinone derivative. In this work, the transient reaction characteristic of piperonal and anthraquinone derivative has been investigated. The transient absorption spectra of the product from electron transfer reaction between piperonal and anthraquinone-2-sulfate was obtained, the electron transfer between electron donor and acceptor was observed directly. (authors)

  7. Development of a collision induced dissociation ion cyclotron resonance spectrometer

    International Nuclear Information System (INIS)

    Fan, Y.N.

    1982-01-01

    A transient analysis ion cyclotron resonance spectrometer is developed to investigate the phenomena of collision induced dissociation. The Fourier transform method and the modified maximum entropy spectral analysis or covariance least square method are implemented in measuring the mass spectrum of the ion ensemble. The Fourier transform method can be used in quantitative analysis while the maximum entropy method as developed here is useful for qualitative analysis only. The cyclotron resonance frequency, relaxation time constant, and the relative ion population are observable from the Fourier transform spectrum. These parameters are very important in investigating collision induced dissociation process and other topics in gas phase chemistry. The ion cyclotron resonance spectrometer is not only developed to study fragments and their abundance from a parent ion, but also to determine the threshold energy and reaction cross section in the collision induced dissociation process. When hard sphere model is used in the ion-molecule collision, the radius of acetone ion measured from the reactive cross section is 2.2 angstrom which is very close to the physical dimension of acetone. The threshold energy for acetone ion in collision induced dissociation process is 1.8 eV which is similar to the result obtained by the angle-resolved mass spectrometer

  8. The performance and application of laser-induced photoacoustic spectrometer

    International Nuclear Information System (INIS)

    Wang Bo; Chen Xi; Yao Jun

    2012-01-01

    Laser-induced photoacoustic spectrometer (LIPAS) is a key instrument can be used in the investigation of radionuclides migration behaviors due to its higher sensitivity for the detection and identification of radionuclides speciation in aqueous solutions. The speciation of radionuclides such as oxidation states and complexation may be determined directly by using this specific non-contact and nondestructive analytical technique, and the sensitivity of LIPAS surpasses that of conventional absorption spectroscopy by one to two orders of magnitude. In the present work, LIPAS system was established at China Institute of Atomic Energy (CIAE), and the principle, performance and preliminary application of LIPAS are also be presented. (authors)

  9. Electron spectrometer for gas-phase spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bozek, J.D.; Schlachter, A.S. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    An electron spectrometer for high-resolution spectroscopy of gaseous samples using synchrotron radiation has been designed and constructed. The spectrometer consists of a gas cell, cylindrical electrostatic lens, spherical-sector electron energy analyzer, position-sensitive detector and associated power supplies, electronics and vacuum pumps. Details of the spectrometer design are presented together with some representative spectra.

  10. Transient Heat Conduction

    DEFF Research Database (Denmark)

    Rode, Carsten

    1998-01-01

    Analytical theory of transient heat conduction.Fourier's law. General heat conducation equation. Thermal diffusivity. Biot and Fourier numbers. Lumped analysis and time constant. Semi-infinite body: fixed surface temperature, convective heat transfer at the surface, or constant surface heat flux...

  11. Airborne gamma ray spectrometer surveying

    International Nuclear Information System (INIS)

    1991-01-01

    The International Atomic Energy Agency (IAEA) in its role as collector and disseminator of information on nuclear techniques has long had an interest in gamma ray spectrometer methods and has published a number of Technical Reports on various aspects of the subject. At an Advisory Group Meeting held in Vienna in November 1986 to review appropriate activities the IAEA could take following the Chernobyl accident, it was recommended that preparation begin on a new Technical Report on airborne gamma ray spectrometer surveying, taking into account the use of the technique for environmental monitoring as well as for nuclear emergency response requirements. Shortly thereafter the IAEA became the lead organization in the Radioelement Geochemical Mapping section of the International Geological Correlation Programme/United Nations Educational, Scientific and Cultural Organization (UNESCO) Project on International Geochemical Mapping. These two factors led to the preparation of the present Technical Report. 18 figs, 4 tabs

  12. Heavy-ion-spectrometer system

    International Nuclear Information System (INIS)

    1982-05-01

    LBL safety policy (Pub 300 Appendix E) states that every research operation with a Class A risk potential (DOE 5484.1) should identify potentially hazardous procedures associated with the operation and develop methods for accomplishing the operation safely without personnel injury or property damage. The rules and practices that management deems to be minimally necessary for the safe operations of the Heavy Ion Spectrometer System (HISS) in the Bevatron Experimental Hall (51B) are set forth in this Operation Safety Procedures

  13. Heavy-ion-spectrometer system

    Energy Technology Data Exchange (ETDEWEB)

    1982-05-01

    LBL safety policy (Pub 300 Appendix E) states that every research operation with a Class A risk potential (DOE 5484.1) should identify potentially hazardous procedures associated with the operation and develop methods for accomplishing the operation safely without personnel injury or property damage. The rules and practices that management deems to be minimally necessary for the safe operations of the Heavy Ion Spectrometer System (HISS) in the Bevatron Experimental Hall (51B) are set forth in this Operation Safety Procedures (OSP).

  14. The HISS spectrometer at LBL

    International Nuclear Information System (INIS)

    Greiner, D.

    1981-01-01

    The Heavy Ion Spectrometer System at LBL is designed to be a general purpose experimental work bench able to support a wide variety of experiments. Our philosophy is to provide instruments capable of investigating, with multi-particle sensitivity, a large portion of phase space. We have not chosen a particular region such as mid-rapidity or projectile frame, but instead, have made sure that the magnet and the instrumentation allow these choices as well as many others. (orig.)

  15. Compressive Transient Imaging

    KAUST Repository

    Sun, Qilin

    2017-04-01

    High resolution transient/3D imaging technology is of high interest in both scientific research and commercial application. Nowadays, all of the transient imaging methods suffer from low resolution or time consuming mechanical scanning. We proposed a new method based on TCSPC and Compressive Sensing to achieve a high resolution transient imaging with a several seconds capturing process. Picosecond laser sends a serious of equal interval pulse while synchronized SPAD camera\\'s detecting gate window has a precise phase delay at each cycle. After capturing enough points, we are able to make up a whole signal. By inserting a DMD device into the system, we are able to modulate all the frames of data using binary random patterns to reconstruct a super resolution transient/3D image later. Because the low fill factor of SPAD sensor will make a compressive sensing scenario ill-conditioned, We designed and fabricated a diffractive microlens array. We proposed a new CS reconstruction algorithm which is able to denoise at the same time for the measurements suffering from Poisson noise. Instead of a single SPAD senor, we chose a SPAD array because it can drastically reduce the requirement for the number of measurements and its reconstruction time. Further more, it not easy to reconstruct a high resolution image with only one single sensor while for an array, it just needs to reconstruct small patches and a few measurements. In this thesis, we evaluated the reconstruction methods using both clean measurements and the version corrupted by Poisson noise. The results show how the integration over the layers influence the image quality and our algorithm works well while the measurements suffer from non-trival Poisson noise. It\\'s a breakthrough in the areas of both transient imaging and compressive sensing.

  16. The superconducting kaon spectrometer - SKS

    International Nuclear Information System (INIS)

    Fukuda, T.; Takahashi, T.; Aoki, K.; Doi, Y.; Kondo, Y.; Makida, Y.; Nomachi, M.; Noumi, H.; Sasaki, O.; Shintomi, T.; Bhang, H.; Park, H.; Youn, M.; Yu, H.; Gavrilov, Y.; Ajimura, S.; Kishimoto, T.; Ohkusu, A.; Shinkai, N.; Maeda, K.; Sawafta, R.

    1995-01-01

    A superconducting kaon spectrometer has been installed in the north experimental hall of the KEK 12-GeV proton synchrotron. The spectrometer was designed to serve for nuclear physics experiments with meson beams in the 1 GeV/c region, particular emphasis being laid on study of Λ-hypernuclei via (π + ,K + ) reactions. In order to obtain Λ-hypernuclear data with better statistics and energy resolution, it was designed to have a good momentum resolution of 0.1% FWHM and a large acceptance of 100 msr. It consists of a large superconducting dipole magnet, tracking chambers, and trigger counters that can efficiently select kaons from large background of pions and protons. The overall energy resolution for scattering is realized together with a beam-line spectrometer in the K6 beam line, the momentum resolution of which was also designed to be better than 0.1% FWHM. A good energy resolution of better than 2 MeV FWHM has been confirmed in π - - 12 C elastic scattering and in the (π + ,K + ) reaction on 12 C. (orig.)

  17. Oxford MDM-2 magnetic spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Pringle, D.M.; Catford, W.N.; Winfield, J.S.; Lewis, D.G.; Jelley, N.A.; Allen, K.W.; Coupland, J.H.

    1986-05-01

    A new high resolution magnetic spectrometer - the Oxford MDM-2 spectrometer - has been designed, installed and tested. The layout of the magnetic elements is in the order: entrance sextupole and multipole, gradient-field dipole and exit multipole. The device has a ''normal'' focal plane, and the 1.6 m radius dipole magnet has a maximum mass-energy product of 315 MeV amu. At the maximum solid angle of 8 msr, the ratio of energies that can be accepted by the spectrometer (Esub(max)/Esub(min)) is 1.31. Precise measurements have been performed on the magnetic elements. The dipole magnet has very low hysteresis and field integral errors that amount to less than 1 part in 10/sup 4/. After some in situ modifications the field distributions of the magnets closely approximated the original design specifications. On-line tests with various ion-beams have revealed the optimum setting for each element. These are close to theoretical predictions from the program RAYTRACE, incorporating the parameterised results of the magnetic measurements. An aberration limited resolution (E/..delta..E) of greater than 3000 has been observed at 8 msr solid angle.

  18. A NMR spectrometer for educational purposes

    International Nuclear Information System (INIS)

    Colnago, Luiz A.; Torre Neto, Andre

    1991-01-01

    A NMR spectrometer has been constructed for educational purposes, such as teaching of the technique basic principles and instrumentation. The spectrometer has been designed with a minimum number of components so that the students may have acquittance with both the spectrometer, through block diagrams, and the small numbers of existent components . The device was based on a 0.t Tesla magnet from the continuous wave spectrometer (E M 300 - Varian) existent at the Instituto Militar de Engenharia, and it is expected to facilitate the comprehension of the commercial spectrometers

  19. Explosive and radio-selected Transients: Transient Astronomy with ...

    Indian Academy of Sciences (India)

    40

    SKA), large samples of explosive transients are expected to be discovered. Radio wavelengths, especially in commensal survey mode, are particularly well suited for uncovering the complex transient phenomena. This is because ob- servations ...

  20. VUV Fourier-Transform absorption study of the np pi (1)Pi(-)(u) nu,N

    NARCIS (Netherlands)

    Glass-Maujean, M.; Jungen, C.; Dickenson, G.D.; Ubachs, W.M.G.; de Oliveira, N.; Joyeux, D.

    2015-01-01

    Abstract The DESIRS beamline of the SOLEIL synchrotron facility, equipped with a vacuum ultraviolet Fourier-Transform spectrometer has been used to measure Q(N″)(N-N″=0) absorption transitions of the D

  1. Multichannel emission spectrometer for high dynamic range optical pyrometry of shock-driven materials

    Science.gov (United States)

    Bassett, Will P.; Dlott, Dana D.

    2016-10-01

    An emission spectrometer (450-850 nm) using a high-throughput, high numerical aperture (N.A. = 0.3) prism spectrograph with stepped fiberoptic coupling, 32 fast photomultipliers and thirty-two 1.25 GHz digitizers is described. The spectrometer can capture single-shot events with a high dynamic range in amplitude and time (nanoseconds to milliseconds or longer). Methods to calibrate the spectrometer and verify its performance and accuracy are described. When a reference thermal source is used for calibration, the spectrometer can function as a fast optical pyrometer. Applications of the spectrometer are illustrated by using it to capture single-shot emission transients from energetic materials or reactive materials initiated by kmṡs-1 impacts with laser-driven flyer plates. A log (time) data analysis method is used to visualize multiple kinetic processes resulting from impact initiation of HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) or a Zr/CuO nanolaminate thermite. Using a gray body algorithm to interpret the spectral radiance from shocked HMX, a time history of temperature and emissivity was obtained, which could be used to investigate HMX hot spot dynamics. Finally, two examples are presented showing how the spectrometer can avoid temperature determination errors in systems where thermal emission is accompanied by atomic or molecular emission lines.

  2. Ion mobility spectrometer / mass spectrometer (IMS-MS).

    Energy Technology Data Exchange (ETDEWEB)

    Hunka Deborah Elaine; Austin, Daniel E.

    2005-07-01

    The use of Ion Mobility Spectrometry (IMS) in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400). Combining Ion Mobility Spectrometry (IMS) with Mass Spectrometry (MS) is described. The IMS-MS combination overcomes several limitations present in simple IMS systems. Ion mobility alone is insufficient to identify an unknown chemical agent. Collision cross section, upon which mobility is based, is not sufficiently unique or predictable a priori to be able to make a confident peak assignment unless the compounds present are already identified. Molecular mass, on the other hand, is much more readily interpreted and related to compounds. For a given compound, the molecular mass can be determined using a pocket calculator (or in one's head) while a reasonable value of the cross-section might require hours of computation time. Thus a mass spectrum provides chemical specificity and identity not accessible in the mobility spectrum alone. In addition, several advanced mass spectrometric methods, such as tandem MS, have been extensively developed for the purpose of molecular identification. With an appropriate mass spectrometer connected to an ion mobility spectrometer, these advanced identification methods become available, providing greater characterization capability.

  3. Ion Mobility Spectrometer / Mass Spectrometer (IMS-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Hunka, Deborah E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Austin, Daniel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2005-10-01

    The use of Ion Mobility Spectrometry (IMS)in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400).

  4. Gas Measurement Using Static Fourier Transform Infrared Spectrometers.

    Science.gov (United States)

    Köhler, Michael H; Schardt, Michael; Rauscher, Markus S; Koch, Alexander W

    2017-11-13

    Online monitoring of gases in industrial processes is an ambitious task due to adverse conditions such as mechanical vibrations and temperature fluctuations. Whereas conventional Fourier transform infrared (FTIR) spectrometers use rather complex optical and mechanical designs to ensure stable operation, static FTIR spectrometers do not require moving parts and thus offer inherent stability at comparatively low costs. Therefore, we present a novel, compact gas measurement system using a static single-mirror Fourier transform spectrometer (sSMFTS). The system works in the mid-infrared range from 650 cm - 1 to 1250 cm - 1 and can be operated with a customized White cell, yielding optical path lengths of up to 120 cm for highly sensitive quantification of gas concentrations. To validate the system, we measure different concentrations of 1,1,1,2-Tetrafluoroethane (R134a) and perform a PLS regression analysis of the acquired infrared spectra. Thereby, the measured absorption spectra show good agreement with reference data. Since the system additionally permits measurement rates of up to 200 Hz and high signal-to-noise ratios, an application in process analysis appears promising.

  5. A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science

    Science.gov (United States)

    Doriese, W. B.; Abbamonte, P.; Alpert, B. K.; Bennett, D. A.; Denison, E. V.; Fang, Y.; Fischer, D. A.; Fitzgerald, C. P.; Fowler, J. W.; Gard, J. D.; Hays-Wehle, J. P.; Hilton, G. C.; Jaye, C.; McChesney, J. L.; Miaja-Avila, L.; Morgan, K. M.; Joe, Y. I.; O'Neil, G. C.; Reintsema, C. D.; Rodolakis, F.; Schmidt, D. R.; Tatsuno, H.; Uhlig, J.; Vale, L. R.; Ullom, J. N.; Swetz, D. S.

    2017-05-01

    We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering

  6. Remote planetary geochemical exploration with the NEAR X-ray/gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Trombka, J.I.; Boynton, W.V.; Brueckner, J.; Squyres, S.; Clark, P.E.; Starr, R.; Evans, L.G.; Floyd, S.R.; McClanahan, T.P.; Goldsten, J.; Mcnutt, R.; Schweitzer, J.S.

    1999-01-01

    The X-ray/gamma-ray spectrometer (XGRS) instrument onboard the Near Earth Asteroid Rendezvous (NEAR) spacecraft will map asteroid 433 Eros in the 0.2 keV to 10 MeV energy region. Measurements of the discrete line X-ray and gamma-ray emissions in this energy domain can be used to obtain both qualitative and quantitative elemental composition maps of the asteroid surface. The NEAR X-ray/gamma-ray spectrometer (XGRS) was turned on for the first time during the week of 7 April 1996. Rendezvous with Eros 433 is expected during December 1998. Observations of solar X-ray spectra during both quiescent and active periods have been made. A gamma-ray transient detection system has been implemented and about three gamma-ray transient events a week have been observed which are associated with either gamma-ray bursts or solar flares

  7. Transient Astrophysics Probe

    Science.gov (United States)

    Camp, Jordan; Transient Astrophysics Probe Team

    2018-01-01

    The Transient Astrophysics Probe (TAP) is a wide-field multi-wavelength transient mission proposed for flight starting in the late 2020s. The mission instruments include unique “Lobster-eye” imaging soft X-ray optics that allow a ~1600 deg2 FoV; a high sensitivity, 1 deg2 FoV soft X-ray telescope; a 1 deg2 FoV Infrared telescope with bandpass 0.6-3 micron; and a set of 8 NaI gamma-ray detectors. TAP’s most exciting capability will be the observation of tens per year of X-ray and IR counterparts of GWs involving stellar mass black holes and neutron stars detected by LIGO/Virgo/KAGRA/LIGO-India, and possibly several per year X-ray counterparts of GWs from supermassive black holes, detected by LISA and Pulsar Timing Arrays. TAP will also discover hundreds of X-ray transients related to compact objects, including tidal disruption events, supernova shock breakouts, and Gamma-Ray Bursts from the epoch of reionization.

  8. Metastability of transient states

    Science.gov (United States)

    Rafailov, Michael K.

    2017-05-01

    High intensity ultrashort pulse causes dramatic perturbations in electronic structure of condensed matter. In the same time energy in high intensity single pulse may not be sufficient to disrupt sample thermal equilibrium. Interesting experimental results in ultrashort pulse photo-excited solids have been reported recently on transient athermal phenomena induced by ultrashort high intensity low energy pulse - phenomena related to both athermal phase transitions and athermal state changes. Athermal non-equilibrium of electronic system - and induced changes in magnetic and optical states, may exist only for a period of time comparable to excited carriers' relaxation time. That time is not sufficient for emerging application ranging from light induced superconductivity to infrared countermeasures. While single pulse interaction with condensed matter leading to transit state appearance is well observed, documented, and, to some extends, explained, one of the major problem is to maintain meta-stability of such transient states. Metastability of athermal non-equilibrium that could last well beyond electronic system relaxation time. The objective of this paper is to discuss some issues and approaches to meta-stability of transient states induced by ultrashort pulses in condensed matter.

  9. Transient or permanent fisheye views

    DEFF Research Database (Denmark)

    Jakobsen, Mikkel Rønne; Hornbæk, Kasper

    2012-01-01

    Transient use of information visualization may support specific tasks without permanently changing the user interface. Transient visualizations provide immediate and transient use of information visualization close to and in the context of the user’s focus of attention. Little is known, however, ...

  10. Nutrition and magnesium absorption

    OpenAIRE

    Brink, E.J.

    1992-01-01

    The influence of various nutrients present in dairy products and soybean-based products on absorption of magnesium has been investigated. The studies demonstrate that soybean protein versus casein lowers apparent magnesium absorption in rats through its phytate component. However, true magnesium absorption was neither affected by soybean protein in the diet nor by supplemental phytate. The inhibitory influence of soybean protein and phytate on apparent magnesium absorption was found ...

  11. Transient Species in Plasmas Interacting with Liquids

    Science.gov (United States)

    Reuter, S.; Schmidt-Bleker, A.; van Helden, J. H.; Jablonowski, H.; Winter, J.; Santos Sousa, J.; Gianella, M.; Ritchie, G.; Weltmann, K.-D.

    2016-09-01

    Processes of non-equilibrium plasmas at gas-liquid interfaces are determined by transient species. Quantification of these species in the plasma, gas, or liquid is intricate and requires specific diagnostics. In order to study plasma-liquid interaction processes, novel diagnostic concepts need to be developed combined with simulations that allow an insight into the chemical reaction pathways. Significantly relevant transient species in plasmas operated in ambient air include HO2 and O2(a1 Δ) , which are diagnosed in this work. The aim is to link localized transient species with longer living stable species in the gas phase and in the liquid phase. Understanding reaction pathways makes it possible to control the reactive species composition generated by the cold plasmas, and further insight into plasma induced reactivity in condensed matter systems can be gained. The work shows a combination of absorption spectroscopic methods and other diagnostic techniques as well as simple kinetics modeling as a way to control the plasma chemical reactions.

  12. Absorption and excretion tests

    International Nuclear Information System (INIS)

    Berberich, R.

    1988-01-01

    The absorption and excretion of radiopharmaceuticals is still of interest in diagnostic investigations of nuclear medicine. In this paper the most common methods of measuring absorption and excretion are described. The performance of the different tests and their standard values are discussed. More over the basic possibilities of measuring absorption and excretion including the needed measurement equipments are presented. (orig.) [de

  13. Interferometric measurement of lines shift in flames in connection with interpretation of lined absorption method in atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    L'vov, B.V.; Polzik, L.K.; Katskov, D.A.; Kruglikova, L.P.

    1975-01-01

    This paper is concerned with interferometric measuring of the line shift in flames in the view of interpretation of absorption lines in the atomic absorption spectroscopy. The newly measured line shifts were compared to the known data on Lorentz broadening of the same lines obtained by methods free of the systematic errors. The resonant lines of the alkaline earth elements (Sr, Ca, Ba) were investigated. To reduce self-absorption in the flame the solutions with minimum concentrations of the elements were used. The computation scheme includes the spectrometer apparatus width and line broadening due to the self-absorption. Formulae are given for computing the values studied. Good agreement was observed between the computed and experimental results. Error analysis was performed. It was concluded that any line shifts in the hydrocarbons were correctly taken into an account in the absolute computations of absorption

  14. The Alpha Magnetic Spectrometer (AMS)

    CERN Document Server

    Alcaraz, J; Ambrosi, G; Anderhub, H; Ao, L; Arefev, A; Azzarello, P; Babucci, E; Baldini, L; Basile, M; Barancourt, D; Barão, F; Barbier, G; Barreira, G; Battiston, R; Becker, R; Becker, U; Bellagamba, L; Bene, P; Berdugo, J; Berges, P; Bertucci, B; Biland, A; Bizzaglia, S; Blasko, S; Bölla, G; Boschini, M; Bourquin, Maurice; Brocco, L; Bruni, G; Buénerd, M; Burger, J D; Burger, W J; Cai, X D; Camps, C; Cannarsa, P; Capell, M; Casadei, D; Casaus, J; Castellini, G; Cecchi, C; Chang, Y H; Chen, H F; Chen, H S; Chen, Z G; Chernoplekov, N A; Tzi Hong Chiueh; Chuang, Y L; Cindolo, F; Commichau, V; Contin, A; Crespo, P; Cristinziani, M; Cunha, J P D; Dai, T S; Deus, J D; Dinu, N; Djambazov, L; Dantone, I; Dong, Z R; Emonet, P; Engelberg, J; Eppling, F J; Eronen, T; Esposito, G; Extermann, P; Favier, Jean; Fiandrini, E; Fisher, P H; Flügge, G; Fouque, N; Galaktionov, Yu; Gervasi, M; Giusti, P; Grandi, D; Grimm, O; Gu, W Q; Hangarter, K; Hasan, A; Hermel, V; Hofer, H; Huang, M A; Hungerford, W; Ionica, M; Ionica, R; Jongmanns, M; Karlamaa, K; Karpinski, W; Kenney, G; Kenny, J; Kim, W; Klimentov, A; Kossakowski, R; Koutsenko, V F; Kraeber, M; Laborie, G; Laitinen, T; Lamanna, G; Laurenti, G; Lebedev, A; Lee, S C; Levi, G; Levchenko, P M; Liu, C L; Liu, H T; Lopes, I; Lu, G; Lü, Y S; Lübelsmeyer, K; Luckey, D; Lustermann, W; Maña, C; Margotti, A; Mayet, F; McNeil, R R; Meillon, B; Menichelli, M; Mihul, A; Mourao, A; Mujunen, A; Palmonari, F; Papi, A; Park, I H; Pauluzzi, M; Pauss, Felicitas; Perrin, E; Pesci, A; Pevsner, A; Pimenta, M; Plyaskin, V; Pozhidaev, V; Postolache, V; Produit, N; Rancoita, P G; Rapin, D; Raupach, F; Ren, D; Ren, Z; Ribordy, M; Richeux, J P; Riihonen, E; Ritakari, J; Röser, U; Roissin, C; Sagdeev, R; Sartorelli, G; Schwering, G; Scolieri, G; Seo, E S; Shoutko, V; Shoumilov, E; Siedling, R; Son, D; Song, T; Steuer, M; Sun, G S; Suter, H; Tang, X W; Ting, Samuel C C; Ting, S M; Tornikoski, M; Torsti, J; Ulbricht, J; Urpo, S; Usoskin, I; Valtonen, E; Vandenhirtz, J; Velcea, F; Velikhov, E P; Verlaat, B; Vetlitskii, I; Vezzu, F; Vialle, J P; Viertel, Gert M; Vitè, Davide F; Gunten, H V; Wallraff, W; Wang, B C; Wang, J Z; Wang, Y H; Wiik, K; Williams, C; Wu, S X; Xia, P C; Yan, J L; Yan, L G; Yang, C G; Yang, M; Ye, S W; Yeh, P; Xu, Z Z; Zhang, H Y; Zhang, Z P; Zhao, D X; Zhu, G Y; Zhu, W Z; Zhuang, H L; Zichichi, A; Zimmermann, B

    2002-01-01

    The Alpha Magnetic Spectrometer (AMS) is a large acceptance (0.65 sr m sup 2) detector designed to operate in the International Space Station (ISS) for three years. The purposes of the experiment are to search for cosmic antimatter and dark matter and to study the composition and energy spectrum of the primary cosmic rays. A 'scaled-down' version has been flown on the Space Shuttle Discovery for 10 days in June 1998. The complete AMS is programmed for installation on the ISS in October 2003 for an operational period of 3 yr. This contribution reports on the experimental configuration that will be installed on the ISS.

  15. The Alpha Magnetic Spectrometer (ams)

    Science.gov (United States)

    Ionica, Maria

    2004-01-01

    The Alpha Magnetic Spectrometer (AMS), once installed on the International Space Station will provide precise measurements of the cosmic ray spectra up to TeV energy range, and will search for cosmological antimatter and missing matter. A prototype version of the detector was operated successfully on the space shuttle Discovery in June 1998 (STS-91). Here we briefly report on the design of the AMS apparatus and present the results of the measurements of the fluxes of proton, electron, positron and helium from the STS-91 flight.

  16. Portable neutron spectrometer and dosimeter

    Science.gov (United States)

    Waechter, D.A.; Erkkila, B.H.; Vasilik, D.G.

    The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.

  17. New spectrometer for charged particles

    International Nuclear Information System (INIS)

    Wajsfelner, Rene

    1970-02-01

    This thesis is devoted to the study and development of an electrostatic spectrometer which is not only more accurate for the determination of size distributions of electrically charged radio-active atmospheric aerosols, but which can also be used for measuring the grain-size distribution of any cloud of particles which will previously have been charged according to a known, reproducible law. An experimental study has been made of the development of this precipitator and also of its calibration. The electrical charge on spherical polystyrene latex particles suspended in air by atomization has been studied; a theoretical explanation of these results is put forward. (author) [fr

  18. The Alpha Magnetic Spectrometer (AMS)

    International Nuclear Information System (INIS)

    Alcaraz, J.; Alpat, B.; Ambrosi, G.; Anderhub, H.; Ao, L.; Arefiev, A.; Azzarello, P.; Babucci, E.; Baldini, L.; Basile, M.; Barancourt, D.; Barao, F.; Barbier, G.; Barreira, G.; Battiston, R.; Becker, R.; Becker, U.; Bellagamba, L.; Bene, P.; Berdugo, J.; Berges, P.; Bertucci, B.; Biland, A.; Bizzaglia, S.; Blasko, S.; Boella, G.; Boschini, M.; Bourquin, M.; Brocco, L.; Bruni, G.; Buenerd, M.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Camps, C.; Cannarsa, P.; Capell, M.; Casadei, D.; Casaus, J.; Castellini, G.; Cecchi, C.; Chang, Y.H.; Chen, H.F.; Chen, H.S.; Chen, Z.G.; Chernoplekov, N.A.; Chiueh, T.H.; Chuang, Y.L.; Cindolo, F.; Commichau, V.; Contin, A.; Crespo, P.; Cristinziani, M.; Cunha, J.P. da; Dai, T.S.; Deus, J.D.; Dinu, N.; Djambazov, L.; DAntone, I.; Dong, Z.R.; Emonet, P.; Engelberg, J.; Eppling, F.J.; Eronen, T.; Esposito, G.; Extermann, P.; Favier, J.; Fiandrini, E.; Fisher, P.H.; Fluegge, G.; Fouque, N.; Galaktionov, Yu.; Gervasi, M.; Giusti, P.; Grandi, D.; Grimm, O.; Gu, W.Q.; Hangarter, K.; Hasan, A.; Hermel, V.; Hofer, H.; Huang, M.A.; Hungerford, W.; Ionica, M.; Ionica, R.; Jongmanns, M.; Karlamaa, K.; Karpinski, W.; Kenney, G.; Kenny, J.; Kim, W.; Klimentov, A.; Kossakowski, R.; Koutsenko, V.; Kraeber, M.; Laborie, G.; Laitinen, T.; Lamanna, G.; Laurenti, G.; Lebedev, A.; Lee, S.C.; Levi, G.; Levtchenko, P.; Liu, C.L.; Liu, H.T.; Lopes, I.; Lu, G.; Lu, Y.S.; Luebelsmeyer, K.; Luckey, D.; Lustermann, W.; Mana, C.; Margotti, A.; Mayet, F.; McNeil, R.R.; Meillon, B.; Menichelli, M.; Mihul, A.; Mourao, A.; Mujunen, A.; Palmonari, F.; Papi, A.; Park, I.H.; Pauluzzi, M.; Pauss, F.; Perrin, E.; Pesci, A.; Pevsner, A.; Pimenta, M.; Plyaskin, V.; Pojidaev, V.; Postolache, V.; Produit, N.; Rancoita, P.G.; Rapin, D.; Raupach, F.; Ren, D.; Ren, Z.; Ribordy, M.; Richeux, J.P.; Riihonen, E.; Ritakari, J.; Roeser, U.; Roissin, C.; Sagdeev, R.; Sartorelli, G.; Schultz von Dratzig, A.; Schwering, G.; Scolieri, G.; Seo, E.S.; Shoutko, V.; Shoumilov, E.; Siedling, R.; Son, D.; Song, T.; Steuer, M.; Sun, G.S.; Suter, H.; Tang, X.W.; Ting, S.C.C.Samuel C.C.; Ting, S.M.; Tornikoski, M.; Torsti, J.; Tr umper, J.; Ulbricht, J.; Urpo, S.; Usoskin, I.; Valtonen, E.; Vandenhirtz, J.; Velcea, F.; Velikhov, E.; Verlaat, B.; Vetlitsky, I.; Vezzu, F.; Vialle, J.P.; Viertel, G.; Vite, D.; Gunten, H. Von; Wicki, S.W.S. Waldmeier; Wallraff, W.; Wang, B.C.; Wang, J.Z.; Wang, Y.H.; Wiik, K.; Williams, C.; Wu, S.X.; Xia, P.C.; Yan, J.L.; Yan, L.G.; Yang, C.G.; Yang, M.; Ye, S.W.; Yeh, P.; Xu, Z.Z.; Zhang, H.Y.; Zhang, Z.P.; Zhao, D.X.; Zhu, G.Y.; Zhu, W.Z.; Zhuang, H.L.; Zichichi, A.; Zimmermann, B.

    2002-01-01

    The Alpha Magnetic Spectrometer (AMS) is a large acceptance (0.65 sr m 2 ) detector designed to operate in the International Space Station (ISS) for three years. The purposes of the experiment are to search for cosmic antimatter and dark matter and to study the composition and energy spectrum of the primary cosmic rays. A 'scaled-down' version has been flown on the Space Shuttle Discovery for 10 days in June 1998. The complete AMS is programmed for installation on the ISS in October 2003 for an operational period of 3 yr. This contribution reports on the experimental configuration that will be installed on the ISS

  19. Ion Mobility Spectrometer Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Nicholas [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; McLain, Derek [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Steeb, Jennifer [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2017-12-20

    The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.

  20. 60 Kelvin Absorption Cell for Planetary Spectroscopic Research

    Science.gov (United States)

    Chackerian, Charles, Jr.; McGee, James; Gore, Warren I. Y. (Technical Monitor)

    1995-01-01

    We will describe a 30 cm long absorption cell which has been in operation for about two years. The cell is designed for use with sensitive-wide-spectral-coverage Fourier transform spectrometers. A helium compressor refrigerator allows temperatures to be achieved down to about 57 K. Heaters allow above-ambient temperatures as well. A unique vibration isolation system effectively quenches the transfer of vibration of the compressor unit to the spectrometer. An acid-resistant stainless steel liner in the copper body of the call permits the use of corrosive gases.

  1. Beta-spectrometer with Si-detectors for the study of 144Ce-144Pr decays

    Science.gov (United States)

    Alexeev, I. E.; Bakhlanov, S. V.; Bazlov, N. V.; Chmel, E. A.; Derbin, A. V.; Drachnev, I. S.; Kotina, I. M.; Muratova, V. N.; Pilipenko, N. V.; Semyonov, D. A.; Unzhakov, E. V.; Yeremin, V. K.

    2018-05-01

    Here we present the specifications of a newly developed beta-spectrometer, based on full absorption Si(Li) detector and thin transmission detector, allowing one to perform efficient separation beta-radiation and accompanying X-rays and gamma radiation. Our method is based on registration of coincident events from both detectors. The spectrometer can be used for precision measurements of various beta-spectra, namely for the beta-spectrum shape study of 144Pr, which is considered to be an advantageous anti-neutrino source for sterile neutrino searches.

  2. Ion cyclotron resonance spectrometer with fourier transformation

    International Nuclear Information System (INIS)

    Pikver, R.; Suurmaa, Eh.; Syugis, A.; Tammik, A.; Lippmaa, Eh.

    1983-01-01

    The ion cyclotron resonance spectrometer with Fourier transformation intended for investigating mass specta and chemical reaction kinetics in the gaseous phase is described. The mass-spectrum of CO and N 2 positive ions is shown. The spectrometer consists of an electromagnet with power supply, a vacuum system, a cell with electronic equipment and a minicomputer. In the vacuum system (5x10 -9 Torr) there is a cubic measuring cell heated up to 400 deg C. The spectrometer mass resolution is of the 10 5 order. The spectrometer is able to operate as a high-resolution analytical mass-spectrometer of positive and negative ions. The experience of the spectrometer operation confirms its effectiveness for investigating ion-molecular reactions, in particular, proton transfer reactions

  3. Calcium absorption and achlorhydria

    International Nuclear Information System (INIS)

    Recker, R.R.

    1985-01-01

    Defective absorption of calcium has been thought to exist in patients with achlorhydria. The author compared absorption of calcium in its carbonate form with that in a pH-adjusted citrate form in a group of 11 fasting patients with achlorhydria and in 9 fasting normal subjects. Fractional calcium absorption was measured by a modified double-isotope procedure with 0.25 g of calcium used as the carrier. Mean calcium absorption (+/- S.D.) in the patients with achlorhydria was 0.452 +/- 0.125 for citrate and 0.042 +/- 0.021 for carbonate (P less than 0.0001). Fractional calcium absorption in the normal subjects was 0.243 +/- 0.049 for citrate and 0.225 +/- 0.108 for carbonate (not significant). Absorption of calcium from carbonate in patients with achlorhydria was significantly lower than in the normal subjects and was lower than absorption from citrate in either group; absorption from citrate in those with achlorhydria was significantly higher than in the normal subjects, as well as higher than absorption from carbonate in either group. Administration of calcium carbonate as part of a normal breakfast resulted in completely normal absorption in the achlorhydric subjects. These results indicate that calcium absorption from carbonate is impaired in achlorhydria under fasting conditions. Since achlorhydria is common in older persons, calcium carbonate may not be the ideal dietary supplement

  4. Digital Spectrometers for Interplanetary Science Missions

    Science.gov (United States)

    Jarnot, Robert F.; Padmanabhan, Sharmila; Raffanti, Richard; Richards, Brian; Stek, Paul; Werthimer, Dan; Nikolic, Borivoje

    2010-01-01

    A fully digital polyphase spectrometer recently developed by the University of California Berkeley Wireless Research Center in conjunction with the Jet Propulsion Laboratory provides a low mass, power, and cost implementation of a spectrum channelizer for submillimeter spectrometers for future missions to the Inner and Outer Solar System. The digital polyphase filter bank spectrometer (PFB) offers broad bandwidth with high spectral resolution, minimal channel-to-channel overlap, and high out-of-band rejection.

  5. The construction of the SPEG spectrometer

    International Nuclear Information System (INIS)

    Gastebois, J.

    1979-01-01

    About two years ago, two distinct types of magnetic spectrometer were proposed. Since then for essentially financial reasons, only one type has been retained by the Scientific Council: the SPEG ('Energy loss spectrometer for GANIL'). This spectrometer is described in a technical document of April 1978. An overall view of the equipment is given here together with a survey of the means necessary for its realization [fr

  6. A computer based Moessbauer spectrometer system

    International Nuclear Information System (INIS)

    Jin Ge; Li Yuzhi; Yin Zejie; Yao Chunbo; Li Tie; Tan Yexian; Wang Jian

    1999-01-01

    A computer based Moessbauer spectrometer system with a single chip processor for online control and data acquisition is developed. The spectrometer is designed as a single-width NIM module and can be performed directly in NIM crate. Because the structure of the spectrometer is designed to be quite flexible, the system is easy to be configured with other kinds of Moessbauer driver, and can be used in other data acquisition systems

  7. Familial Transient Global Amnesia

    Directory of Open Access Journals (Sweden)

    R.Rhys Davies

    2012-12-01

    Full Text Available Following an episode of typical transient global amnesia (TGA, a female patient reported similar clinical attacks in 2 maternal aunts. Prior reports of familial TGA are few, and no previous account of affected relatives more distant than siblings or parents was discovered in a literature survey. The aetiology of familial TGA is unknown. A pathophysiological mechanism akin to that in migraine attacks, comorbidity reported in a number of the examples of familial TGA, is one possibility. The study of familial TGA cases might facilitate the understanding of TGA aetiology.

  8. Thermal transient anemometer

    Science.gov (United States)

    Bailey, James L.; Vresk, Josip

    1989-01-01

    A thermal transient anemometer having a thermocouple probe which is utilized to measure the change in temperature over a period of time to provide a measure of fluid flow velocity. The thermocouple probe is located in the fluid flow path and pulsed to heat or cool the probe. The cooling of the heated probe or the heating of the cooled probe from the fluid flow over a period of time is measured to determine the fluid flow velocity. The probe is desired to be locally heated near the tip to increase the efficiency of devices incorporating the probe.

  9. [Study on lead absorption in pumpkin by atomic absorption spectrophotometry].

    Science.gov (United States)

    Li, Zhen-Xia; Sun, Yong-Dong; Chen, Bi-Hua; Li, Xin-Zheng

    2008-07-01

    A study was carried out on the characteristic of lead absorption in pumpkin via atomic absorption spectrophotometer. The results showed that lead absorption amount in pumpkin increased with time, but the absorption rate decreased with time; And the lead absorption amount reached the peak in pH 7. Lead and cadmium have similar characteristic of absorption in pumpkin.

  10. Transient regional osteoporosis

    Directory of Open Access Journals (Sweden)

    F. Trotta

    2011-09-01

    Full Text Available Transient osteoporosis of the hip and regional migratory osteoporosis are uncommon and probably underdiagnosed bone diseases characterized by pain and functional limitation mainly affecting weight-bearing joints of the lower limbs. These conditions are usually self-limiting and symptoms tend to abate within a few months without sequelae. Routine laboratory investigations are unremarkable. Middle aged men and women during the last months of pregnancy or in the immediate post-partum period are principally affected. Osteopenia with preservation of articular space and transitory edema of the bone marrow provided by magnetic resonance imaging are common to these two conditions, so they are also known by the term regional transitory osteoporosis. The appearance of bone marrow edema is not specific to regional transitory osteoporosis but can be observed in several diseases, i.e. trauma, reflex sympathetic dystrophy, avascular osteonecrosis, infections, tumors from which it must be differentiated. The etiology of this condition is unknown. Pathogenesis is still debated in particular the relationship with reflex sympathetic dystrophy, with which regional transitory osteoporosis is often identified. The purpose of the present review is to remark on the relationship between transient osteoporosis of the hip and regional migratory osteoporosis with particular attention to the bone marrow edema pattern and relative differential diagnosis.

  11. Transient congenital hypothyroidism

    Directory of Open Access Journals (Sweden)

    Nisha Bhavani

    2011-01-01

    Full Text Available Transient thyroid function abnormalities in the new born which revert back to normal after varying periods of time are mostly identified in the neonatal screening tests for thyroid and are becoming more common because of the survival of many more premature infants. It can be due to factors primarily affecting the thyroid-like iodine deficiency or excess, maternal thyroid-stimulating hormone receptor (TSHR antibodies, maternal use of antithyroid drugs, DUOX 2 (dual oxidase 2 mutations, and prematurity or those that affect the pituitary-like untreated maternal hyperthyroidism, prematurity, and drugs. Most of these require only observation, whereas some, such as those due to maternal TSHR antibodies may last for upto three-to-six months and may necessitate treatment. Isolated hyperthyrotropinemia (normal Tetraiodothyronine (T4 and high Thyroid Stimulating hormone (TSH may persist as subclinical hypothyroidism in childhood. Transient hypothyroxinemia (low T4 and normal TSH is very common in premature babies. The recognition of these conditions will obviate the risks associated with unnecessary thyroxine supplementation in childhood and parental concerns of a life long illness in their offspring.

  12. THz Electro-absorption Effect in Quantum Dots

    DEFF Research Database (Denmark)

    Turchinovich, Dmitry; Monozon, Boris S.; Livshits, Daniil A.

    2011-01-01

    In a THz pump - optical probe experiment we demonstrate an instantaneous electro-absorption effect in InGaAs/GaAs quantum dots, induced by the electric field of a single-cycle THz pulse with 3 THz bandwidth and with free-space peak electric field reaching 220 kV/cm. The transient modulation of QD...

  13. Time-of-flight spectrometers

    International Nuclear Information System (INIS)

    Carrico, J.P.

    1976-01-01

    The flight time of an ion in an inhomogeneous, oscillatory electric field (IOFE) is an m/e-dependent property of this field and is independent of the initial position and velocity. The d.c. component of the equation of motion for an ion in the IOFE describes a harmonic oscillation of constant period. When ions oscillate for many periods with one species overtaking another the motion may no longer be truly periodic although the resulting period or 'quasi-period' still remains independent of the initial conditions. This period or 'quasi-period' is used in the time-of-flight mass spectrometer described. The principle of operation is also described and both analytical and experimental results are reported. (B.D.)

  14. The BNL multiparticle spectrometer software

    International Nuclear Information System (INIS)

    Saulys, A.C.

    1985-01-01

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the programm controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both ''on-line'' and ''off-line'' operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed. (orig.)

  15. The Geostationary Fourier Transform Spectrometer

    Science.gov (United States)

    Key, Richard; Sander, Stanley; Eldering, Annmarie; Blavier, Jean-Francois; Bekker, Dmitriy; Manatt, Ken; Rider, David; Wu, Yen-Hung

    2012-01-01

    The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for a geostationary orbit (GEO) earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. GEO allows GeoFTS to continuously stare at a region of the earth for frequent sampling to capture the variability of biogenic fluxes and anthropogenic emissions from city to continental spatial scales and temporal scales from diurnal, synoptic, seasonal to interannual. The measurement strategy provides a process based understanding of the carbon cycle from contiguous maps of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) collected many times per day at high spatial resolution (2.7kmx2.7km at nadir). The CO2/CH4/CO/CF measurement suite in the near infrared spectral region provides the information needed to disentangle natural and anthropogenic contributions to atmospheric carbon concentrations and to minimize uncertainties in the flow of carbon between the atmosphere and surface. The half meter cube size GeoFTS instrument is based on a Michelson interferometer design that uses all high TRL components in a modular configuration to reduce complexity and cost. It is self-contained and as independent of the spacecraft as possible with simple spacecraft interfaces, making it ideal to be a "hosted" payload on a commercial communications satellite mission. The hosted payload approach for measuring the major carbon-containing gases in the atmosphere from the geostationary vantage point will affordably advance the scientific understating of carbon cycle processes and climate change.

  16. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  17. Real time measurement of transient event emissions of air toxics by tomographic remote sensing in tandem with mobile monitoring

    Science.gov (United States)

    Olaguer, Eduardo P.; Stutz, Jochen; Erickson, Matthew H.; Hurlock, Stephen C.; Cheung, Ross; Tsai, Catalina; Colosimo, Santo F.; Festa, James; Wijesinghe, Asanga; Neish, Bradley S.

    2017-02-01

    During the Benzene and other Toxics Exposure (BEE-TEX) study, a remote sensing network based on long path Differential Optical Absorption Spectroscopy (DOAS) was set up in the Manchester neighborhood beside the Ship Channel of Houston, Texas in order to perform Computer Aided Tomography (CAT) scans of hazardous air pollutants. On 18-19 February 2015, the CAT scan network detected large nocturnal plumes of toluene and xylenes most likely associated with railcar loading and unloading operations at Ship Channel petrochemical facilities. The presence of such plumes during railcar operations was confirmed by a mobile laboratory equipped with a Proton Transfer Reaction-Mass Spectrometer (PTR-MS), which measured transient peaks of toluene and C2-benzenes of 50 ppb and 57 ppb respectively around 4 a.m. LST on 19 February 2015. Plume reconstruction and source attribution were performed using the 4D variational data assimilation technique and a 3D micro-scale forward and adjoint air quality model based on both tomographic and PTR-MS data. Inverse model estimates of fugitive emissions associated with railcar transfer emissions ranged from 2.0 to 8.2 kg/hr for toluene and from 2.2 to 3.5 kg/hr for xylenes in the early morning of 19 February 2015.

  18. Probing Transient Electron Dynamics Using Ultrafast X Rays

    Science.gov (United States)

    Bucksbaum, Philip

    2016-05-01

    Linear x-ray absorption in atoms or molecules creates highly excited multi-electron quantum systems, which relax rapidly by fluorescence or Auger emission. These relaxation rates are usually less than a few femtoseconds in duration, and so they can reveal transient elecronic states in molecules as they undergo photo-induced transformations. I will show recent results from femtosecond x-ray experiments that display this phenomenon. There are efforts underway to push the temporal resolving power of ultrafast x-ray pulses into the attosecond regime, using stronger fields to initiate nonlinear absorption processes such as transient stimulated electronic Raman scattering. I will discuss current progress and future prospects for research in this area. This research is supported through Stanford PULSE Institute, SLAC National Accelerator Lab by the U.S. Department of Energy, Office of Basic Energy Sciences, Atomic, Molecular, and Optical Science Program.

  19. Aerosol optical absorption measurements with photoacoustic spectroscopy

    Science.gov (United States)

    Liu, Kun; Wang, Lei; Liu, Qiang; Wang, Guishi; Tan, Tu; Zhang, Weijun; Chen, Weidong; Gao, Xiaoming

    2015-04-01

    Many parameters related to radiative forcing in climate research are known only with large uncertainties. And one of the largest uncertainties in global radiative forcing is the contribution from aerosols. Aerosols can scatter or absorb the electromagnetic radiation, thus may have negative or positive effects on the radiative forcing of the atmosphere, respectively [1]. And the magnitude of the effect is directly related to the quantity of light absorbed by aerosols [2,3]. Thus, sensitivity and precision measurement of aerosol optical absorption is crucial for climate research. Photoacoustic spectroscopy (PAS) is commonly recognized as one of the best candidates to measure the light absorption of aerosols [4]. A PAS based sensor for aerosol optical absorption measurement was developed. A 532 nm semiconductor laser with an effective power of 160 mW was used as a light source of the PAS sensor. The PAS sensor was calibrated by using known concentration NO2. The minimum detectable optical absorption coefficient (OAC) of aerosol was determined to be 1 Mm-1. 24 hours continues measurement of OAC of aerosol in the ambient air was carried out. And a novel three wavelength PAS aerosol OAC sensor is in development for analysis of aerosol wavelength-dependent absorption Angstrom coefficient. Reference [1] U. Lohmann and J. Feichter, Global indirect aerosol effects: a review, Atmos. Chem. Phys. 5, 715-737 (2005) [2] M. Z. Jacobson, Strong radiative heating due to the mixing state of black carbon in atmospheric aerosols, Nature 409, 695-697 (2001) [3] V. Ramanathan and G. Carmichae, Global and regional climate changes due to black carbon, nature geoscience 1, 221-227 (2008) [4] W.P Arnott, H. Moosmuller, C. F. Rogers, T. Jin, and R. Bruch, Photoacoustic spectrometer for measuring light absorption by aerosol: instrument description. Atmos. Environ. 33, 2845-2852 (1999).

  20. Transient osteoporosis of the hip

    International Nuclear Information System (INIS)

    McWalter, Patricia; Hassan Ahmed

    2007-01-01

    Transient osteoporosis of the hip is an uncommon cause of hip pain, mostly affecting healthy middle-aged men and also women in the third trimester of pregnancy. We present a case of transient osteoporosis of the hip in a 33-year-old non-pregnant female patient. This case highlights the importance of considering a diagnosis of transient osteoporosis of the hip in patients who present with hip pain. (author)

  1. Laboratory EXAFS Spectrometer, Principles and Applications

    NARCIS (Netherlands)

    Koningsberger, D.C.; Kampers, F.W.H.; Duivenvoorden, F.B.M.; Zon, J.B.A.D. van; Brinkgreve, P.; Viegers, M.P.A.

    1985-01-01

    In order to be independent of poor availability of synchrotron beamtime a laboratory EXAFS spectrometer has been developed. The X-ray source is a rotating anode generator (max. voltage 60 kV, max. current 300 mA). Monochromatisation and focusing is done with a linear spectrometer, based upon the

  2. The high momentum spectrometer drift chambers

    Science.gov (United States)

    Abbott, D.; Baker, O. K.; Beaufait, J.; Bennett, C.; Bryant, E.; Carlini, R.; Kross, B.; McCauley, A.; Naing, W.; Shin, T.; Vulcan, W.

    1992-12-01

    The High Momentum Spectrometer in Hall C will use planar drift chambers for charged particle track reconstruction. The chambers are constructed using well understood technology and a conventional gas mixture. Two (plus one spare) drift chambers will be constructed for this spectrometers. Each chamber will contain 6 planes of readout channels. This paper describes the chamber design and gas handling system used.

  3. The MIRI Medium Resolution Spectrometer calibration pipeline

    NARCIS (Netherlands)

    Labiano, A.; Azzollini, R.; Bailey, J.; Beard, S.; Dicken, D.; García-Marín, M.; Geers, V.; Glasse, A.; Glauser, A.; Gordon, K.; Justtanont, K.; Klaassen, P.; Lahuis, F.; Law, D.; Morrison, J.; Müller, M.; Rieke, G.; Vandenbussche, B.; Wright, G.

    2016-01-01

    The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is the only mid-IR Integral Field Spectrometer on board James Webb Space Telescope. The complexity of the MRS requires a very specialized pipeline, with some specific steps not present in other pipelines of JWST instruments,

  4. A Mass Spectrometer Simulator in Your Computer

    Science.gov (United States)

    Gagnon, Michel

    2012-01-01

    Introduced to study components of ionized gas, the mass spectrometer has evolved into a highly accurate device now used in many undergraduate and research laboratories. Unfortunately, despite their importance in the formation of future scientists, mass spectrometers remain beyond the financial reach of many high schools and colleges. As a result,…

  5. Camtracker: a new camera controlled high precision solar tracker system for FTIR-spectrometers

    Directory of Open Access Journals (Sweden)

    M. Gisi

    2011-01-01

    Full Text Available A new system to very precisely couple radiation of a moving source into a Fourier Transform Infrared (FTIR Spectrometer is presented. The Camtracker consists of a homemade altazimuthal solar tracker, a digital camera and a homemade program to process the camera data and to control the motion of the tracker. The key idea is to evaluate the image of the radiation source on the entrance field stop of the spectrometer. We prove that the system reaches tracking accuracies of about 10 arc s for a ground-based solar absorption FTIR spectrometer, which is significantly better than current solar trackers. Moreover, due to the incorporation of a camera, the new system allows to document residual pointing errors and to point onto the solar disk center even in case of variable intensity distributions across the source due to cirrus or haze.

  6. Detection of fatty product falsifications using a portable near infrared spectrometer

    Directory of Open Access Journals (Sweden)

    Kalinin A.V.

    2017-01-01

    Full Text Available Spreading sales of counterfeited fatty-oil foods leads to a development of portable and operational analyzer of typical fatty acids (FA which may be a near infrared (NIR spectrometer. In this work the calibration models for prediction of named FA were built with the spectra of FT-NIR spectrometer for different absorption bands of the FA. The best parameters were obtained for the wavelength sub-band 1.0-1.8 μ, which includes the 2nd and 3rd overtones of C-H stretching vibrations (near 1.7 and 1.2 μ and the combination band (1.42 μ. Applicability of the portable spectrometer based on linear NIR array photosensor for the quality analysis of spread, butter and fish oil by the typical FA has been tested.

  7. Modeling mini-orange electron spectrometers

    International Nuclear Information System (INIS)

    Canzian da Silva, Nelson; Dietzsch, Olacio

    1994-01-01

    A method for calculating the transmission of mini-orange electron spectrometers is presented. The method makes use of the analytical solution for the magnetic field of a plane magnet in the calculation of the spectrometer spatial field distribution by superimposing the fields of the several magnets that compose the system. Electron trajectories through the spectrometer are integrated numerically in a Monte Carlo calculation and the transmission of the spectrometer as a function of the electron energy is evaluated. A six-magnet mini-orange spectrometer was built and its transmission functions for several distances from source to detector were measured and compared to the calculations. The overall agreement is found to be good. The method is quite general and can be applied to the design of systems composed of plane magnets, predicting their performance before assembling them. ((orig.))

  8. Ultraviolet light absorption of an ophthalmic formulation with Aloe extracts.

    Science.gov (United States)

    Ji, Yimei; Jia, Jicheng

    2009-09-01

    Aloin and polysaccharide present in extracts of Aloe arborescens Miller were formulated into a binary solution to protect eyes from bacterial infection and ultraviolet radiation (UVR). The UVR absorption spectrum was recorded from 190 to 440 nm using a UV spectrometer. The physical properties of the product were examined in terms of its appearance, odor, pH, viscosity, density, refractive index, and stability. The binary solution exhibited three absorption peaks in the UVA, B and C regions, respectively. Such UV absorption capability was attributed to the phenolic chromophores pertaining to aloin. The present study suggested that the formulated binary solution has potential application as an UV absorption agent with built-in antimicrobial activity.

  9. Atmospheric water vapor absorption at 1.3 microm.

    Science.gov (United States)

    Bragg, S L; Kelley, J D

    1987-02-01

    Absolute absorption cross sections for water vapor and water vapor/air mixtures were measured in a frequency range encompassing that of the chemically pumped atomic iodine laser. Measurements were made with a temperature-controlled multipass absorption cell and a high-resolution Fourier transform spectrometer. The measurements covered a broad range of water vapor and air pressures. Several techniques of data analysis were used, and the absorption cross section of 2 kPa of water vapor in an atmosphere of air was determined to be 1.1 +/- 0.2 x 10(-24) cm(2) . In this paper, an expression is derived which allows estimation of the absorption cross section for any pressure of water vapor and air.

  10. A new on-axis multimode spectrometer for the macromolecular crystallography beamlines of the Swiss Light Source

    International Nuclear Information System (INIS)

    Owen, Robin L.; Pearson, Arwen R.; Meents, Alke; Boehler, Pirmin; Thominet, Vincent; Schulze-Briese, Clemens

    2009-01-01

    Complementary techniques greatly aid the interpretation of macromolecule structures to yield functional information, and can also help to track radiation-induced changes. A new on-axis spectrometer being integrated into the macromolecular crystallography beamlines of the Swiss Light Source is presented. X-ray crystallography at third-generation synchrotron sources permits tremendous insight into the three-dimensional structure of macromolecules. Additional information is, however, often required to aid the transition from structure to function. In situ spectroscopic methods such as UV–Vis absorption and (resonance) Raman can provide this, and can also provide a means of detecting X-ray-induced changes. Here, preliminary results are introduced from an on-axis UV–Vis absorption and Raman multimode spectrometer currently being integrated into the beamline environment at X10SA of the Swiss Light Source. The continuing development of the spectrometer is also outlined

  11. Transient Go: A Mobile App for Transient Astronomy Outreach

    Science.gov (United States)

    Crichton, D.; Mahabal, A.; Djorgovski, S. G.; Drake, A.; Early, J.; Ivezic, Z.; Jacoby, S.; Kanbur, S.

    2016-12-01

    Augmented Reality (AR) is set to revolutionize human interaction with the real world as demonstrated by the phenomenal success of `Pokemon Go'. That very technology can be used to rekindle the interest in science at the school level. We are in the process of developing a prototype app based on sky maps that will use AR to introduce different classes of astronomical transients to students as they are discovered i.e. in real-time. This will involve transient streams from surveys such as the Catalina Real-time Transient Survey (CRTS) today and the Large Synoptic Survey Telescope (LSST) in the near future. The transient streams will be combined with archival and latest image cut-outs and other auxiliary data as well as historical and statistical perspectives on each of the transient types being served. Such an app could easily be adapted to work with various NASA missions and NSF projects to enrich the student experience.

  12. Transient optical gain in germanium quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Chatterjee, Sangam; Lange, Christoph; Koester, Niko S.; Schaefer, Martin; Kira, Mackillo; Koch, Stephan W. [Faculty of Physics and Materials Sciences Center, Philipps-Universitaet Marburg (Germany); Chrastina, Daniel; Isella, Giovanni; Kaenel, Hans von [CNISM, Como (Italy); L-NESS, Dipartimento di Fisica del Politecnico di Milano, Como (Italy); Sigg, Hans [Laboratory for Micro and Nanotecnology, Paul Scherrer Institut, Villigen PSI (Switzerland)

    2010-07-01

    One of today's most-sought goals in semiconductor technology is the monolithic integration of microelectronics and photonics on Si. Optical gain is, in general, not expected for Si and Ge or its alloys due to the indirect nature of the band gap in this material system. Here, we show that Ge/SiGe QWs show transient optical gain and may thus be used as an optically-pumped amplifier at room temperature. Further, the nonequilibrium effects which govern the relaxation dynamics of the optically injected carrier distributions in this material were observed and analyzed using a microscopic many-body theory. Strong non-equilibrium gain was obtained on a sub-100 fs time scale. Long-lived gain arising from {gamma}-point transitions is overcompensated by a process bearing the character of free carrier absorption.

  13. Thermal neutron spectra measurements in IEAR-1 Reactor, by using a crystal spectrometer

    International Nuclear Information System (INIS)

    Fulfaro, R.; Figueiredo Neto, A.M.; Stasiulevicius, E.; Vinhas, L.A.

    1975-01-01

    The thermal neutron spectrum of the IEN Argonauta reactor has been measured in the wavelength from 0.7 to 1.9A, using a neutron crystal spectrometer. An aluminium single crystal, in transmission, was used as monochromator. The aluminium crystal reflectivity employed in the analysis of the data was calculated for the first five permitted orders. An effective absorption coefficient of the crystal was used to perform the calculations instead of the macroscopic cross section of the element

  14. Solar absorption surface panel

    Science.gov (United States)

    Santala, Teuvo J.

    1978-01-01

    A composite metal of aluminum and nickel is used to form an economical solar absorption surface for a collector plate wherein an intermetallic compound of the aluminum and nickel provides a surface morphology with high absorptance and relatively low infrared emittance along with good durability.

  15. Nutrition and magnesium absorption

    NARCIS (Netherlands)

    Brink, E.J.

    1992-01-01

    The influence of various nutrients present in dairy products and soybean-based products on absorption of magnesium has been investigated. The studies demonstrate that soybean protein versus casein lowers apparent magnesium absorption in rats through its phytate component. However, true

  16. Infrared absorption spectroscopy with color center lasers

    Science.gov (United States)

    Carrick, P. G.; Curl, R. F.; Tittel, F. K.; Koester, E.; Pfeiffer, J.; Kasper, J. V. V.

    Results are presented of the application of a computer controlled color center laser combined with Stark modulation and magnetic rotation effect modulation for obtaining high resolution spectra of molecular species. The lowest electronic transition of the C2H free radical, of interest in astrophysics, is observed near 3772/cm and the high resolution spectra of methanol and hydroxylamine in the OH stretching region are obtained. It is concluded that color center laser absorption spectroscopy combined with sensitivy enhancement through modulation techniques is a sensitive and versatile means of determining the spectra of free radicals and transient molecules in the infared region.

  17. Nonspecific competition underlies transient attention

    NARCIS (Netherlands)

    Wilschut, A.M.; Theeuwes, J.; Olivers, C.N.L.

    2015-01-01

    Cueing a target by abrupt visual stimuli enhances its perception in a rapid but short-lived fashion, an effect known as transient attention. Our recent study showed that when targets are cued at a constant, central location, the emergence of the transient performance pattern was dependent on the

  18. Transients by substructuring with DMAP

    Science.gov (United States)

    Butler, T. G.

    1978-01-01

    Automated substructuring in level 16 of NASTRAN was employed as a preface to the solution of a direct transient analysis. The DMAP ALTER statements written to adapt the substructuring for transient purposes are explained. Data recovery was accomplished with transfer functions. Proof of the success of the method is presented with an application to a missile structure.

  19. Ion Acceleration Inside Foreshock Transients

    Science.gov (United States)

    Liu, Terry Z.; Lu, San; Angelopoulos, Vassilis; Lin, Yu; Wang, X. Y.

    2018-01-01

    Recent observations upstream of Earth's bow shock have revealed that foreshock transients can not only accelerate solar wind ions by reflection at their upstream boundaries but may also accelerate ions inside them. Evidence for the latter comes from comparisons of ion spectra inside and outside the cores, and from evidence of leakage of suprathermal ions from the cores. However, definite evidence for, and the physics of, ion acceleration in the foreshock transients are still open questions. Using case studies of foreshock transients from Time History of Events and Macroscale Interactions during Substorms observations, we reveal an ion acceleration mechanism in foreshock transients that is applicable to 25% of the transients. The ion energy flux is enhanced between several keV to tens of keV in the cores. We show that these energetic ions are reflected at the earthward moving boundary of foreshock transients, are accelerated through partial gyration along the convection electric field, and can leak out both upstream and downstream of the foreshock transients. Using ions moving self-consistently with a generic 3-D global hybrid simulation of a foreshock transient, we confirm this physical picture of ion acceleration and leakage. These accelerated ions could be further accelerated at the local bow shock and repopulate the foreshock, increasing the efficacy of solar wind-magnetosphere interactions.

  20. Pressure transients in pipeline systems

    DEFF Research Database (Denmark)

    Voigt, Kristian

    1998-01-01

    This text is to give an overview of the necessary background to do investigation of pressure transients via simulations. It will describe briefly the Method of Characteristics which is the defacto standard for simulating pressure transients. Much of the text has been adopted from the book Pressur...

  1. [The coding correction of slit diffraction in Hadamard transform spectrometer].

    Science.gov (United States)

    Li, Bo; Wang, Shu-Rong; Huang, Yu; Wang, Jun-Bo

    2013-08-01

    According to the principles of Hadamard transform spectrometer and the slit diffraction characteristics, the influence of spectrometer entrance slit diffraction of Hadamard transform spectrometer on the measurement result was analyzed, for the diffraction case, the Hadamard transform spectrometer instrument structure matrix was studied, and the Hadamard transform spectrometer encoding/decoding method was established. The analysis of incident spectral verified the correctness of the coding/ decoding. This method is very important for the high precision measurement of Hadamard transform spectrometer.

  2. Transient Enhanced Diffusion

    Science.gov (United States)

    Gossmann, Hans-Joachim L.

    1996-03-01

    Ion implantation is the standard method for dopant introduction during integrated circuit manufacturing, determining crucial device characteristics. Implantation creates point-defects, such as Si self-interstitials and vacancies, far in excess of equilibrium concentrations. Since the diffusion of common dopants involves Si point defects, the interaction of damage and dopants during subsequent annealing steps leads to the phenomenon known as "transient enhanced diffusion" (TED): The dopant diffusivities are enhanced, possibly by many orders of magnitude. The enhancement is transient since the intrinsic defects eventually diffuse into the bulk or annihilate at the surface. The desired specific dopant profile of the device is thus the result of a complex reaction, involving the creation of damage and its spatial distribution, diffusion, and interaction of the point defects among themselves and with interfaces and other defects. As device dimensions shrink and experiments become more and more expensive, the capability to predict these kinds of non-equilibrium phenomena accurately becomes crucial to Si technology development. In our experiments to extract physical mechanisms and parameters of TED we use the method of sharp B- and Sb doping spikes to track interstitial and vacancy concentrations as a function of depth during processing. Thus we gain sensitivity to small diffusion distances (low temperatures) and separate the damaged region from the region of the interaction with dopants. In addition, our method yields directly the actual point defect diffusivity. Although an ion implant initially produces Frenkel pairs, Monte-carlo simulations show that the vacancies annihilate quickly. The excess interstitials, roughly one for each implanted ion coalesce into 311defects. The subsequent evaporation of interstitials from 311ś drives TED. Si interstitial diffusion is influenced by carbon-related traps and we will demonstrate that this finding reconciles quantitatively a

  3. Raman spectrometer with microprobe capability

    Science.gov (United States)

    Boyd, J. T.; Jackson, H. E.

    1986-01-01

    This report describes the results of this equipment grant funded as a part of the Department of Defense (DOD) University Research Instrumentation Program. This grant funded the purchase of a Raman spectrometer with microprobe capability having resolution of 1.0 micron. This report describes the equipment selecting decision, the configuration of the instrument selected, and some experimental results. The experimental results include Raman spectra used in characterization of laser recrystallized silicon and ion implanted regions in semi-insulating GaAs. The Raman microprobe can be used to characterize the effects of substrate temperature, beam power density and shape, beam scan speed and direction, deposition rate, substrate seeding, and polysilicon encapsulation schemes both near and away from grain boundaries. The frequency shift and the peak width of the Raman scattering from the triply degenerate zone center phonon in Si allow determination of the strain in the grains of laser recrystallized polysilicon. Reducing these strains will allow us to achieve large single grains of device quality.

  4. Diode laser MIR-DFG spectrometer for trace gas detection

    Science.gov (United States)

    Willer, Ulrike; Blanke, Torsten; Schade, Wolfgang

    1996-10-01

    Two cw-single mode diode-lasers with powers of 30 and 50 mW at the center wavelengths 682 and 791 nm are applied as signal and pump sources for difference frequency generation (DFG) in an AgGaS2 crystal with a length of 30 mm. For 90 degree type I phase matching tunable mid-infrared laser radiation is obtained in the spectral range between 4.9 and 5.1 micrometers , while the DFG-output power is 0.2 (mu) W. The performance of this diode-laser MIR-DFG spectrometer is shown as the absorption of CO for the P(28) rotational line around 2023 cm-1 is probed in a cell and on-line in the exhaust of an engine.

  5. An Infrared Drill Borehole Spectrometer for Mars

    Science.gov (United States)

    Smythe, W.; Foote, M.; Johnson, E.; Daly, J.; Loges, P.; Puscasu, I.; Gorevan, S.; Chu, P.; Granahan, J.

    2005-08-01

    The best clues to Mars past may be hidden below the surface of Mars. Long exposure to the sun, high winds and dust storms, large diurnal temperature excursions, and eons of space weathering combine to render a greatly modified surface, in many instances remarkable for its appearance of uniform composition. Drilling can provide access to the layers in the caps, to the permafrost and possibly, to pristine crustal material. The drilling process is complex with high demand on support resources. It is vital to make the drilling process as efficient as possible. A most promising approach is to instrument the drill string itself, thereby avoiding the complexity of sample handling, speeding and simplifying drill operations, and allowing examination of freshly exposed surfaces within the borehole. A solid-state IR spectrometer is being integrated with a blackbody source into a package to fit within an existing Mars drill design. The borehole IR spectrometer is used to monitor facies encountered throughout the drilling process. The spectrometer/IR combination is used in reflectance spectrometer mode to monitor H2O and CO2 content, as well as iron and carbonate mineralogies. Integration required adapting the existing spectrometer to fit within the drill -- including attaching the detectors directly to the spectrometer waveguide, developing the techniques required to seal the micro-thermopile detectors to the waveguide, implementing miniaturized digital conversion electronics, combining the spectrometer with the IR source and coupling them to a suitable window, implementing a suitable sealed package to fit within the drill, integrating and testing the package on a drill, and establishing the proper gain for both stimulus and spectrometer to permit reasonable range of Mars soil analogs. Tests have shown that both sapphire and diamond windows perform well in the drilling environment. Testing of the integrated spectrometer and drill will be completed in the coming year.

  6. Demonstration of a highly sensitive photoacoustic spectrometer based on a miniaturized all-optical detecting sensor.

    Science.gov (United States)

    Zhou, Sheng; Slaman, Martin; Iannuzzi, Davide

    2017-07-24

    We report on the development of a highly sensitive photoacoustic (PA) spectrometer based on a miniaturized all-optical detecting sensor. The sensor has a cell volume of less than 6 μL and relies on a cantilever-based acoustic transducer, which is equipped with an optical fiber interferometric readout. The spectrometer reaches a noise equivalent concentration of 15 ppb (300 ms time constant) for acetylene detection using a 23 mW excitation laser source, which corresponds to a normalized noise equivalent absorption coefficient of 7.7 × 10 -10 W cm -1 Hz -1/2 . The performance offered by this PA spectrometer is thus comparable to those reported for bulkier PA analyzers. Furthermore, because both the excitation and detection signals are brought to the PA cell via optical fibers, our spectrometer can be used in harsh environments, where electronic devices are prone to failure, and it is specially suitable for multiplexed remote detection applications. We believe that our study paves the way for the development of PA spectrometers that allow in-situ gas detection in space-limited circumstances.

  7. Advanced, Compact, Ultraviolet Imaging Spectrometer for Planetary Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced, Compact, Ultraviolet Imaging Spectrometer for Planetary Systems will advance the capabilities of ultraviolet imaging spectrometers by improving the...

  8. Progress report of a static Fourier transform spectrometer breadboard

    Science.gov (United States)

    Rosak, A.; Tintó, F.

    2017-11-01

    MOLI instrument -for MOtionLess Interferometer- takes advantage of the new concept of static Fourier transform spectrometer. It is a high-resolution spectrometer working over a narrow bandwidth, which is adapted to a wide range of atmospheric sounding missions and compatible with micro-satellite platform. The core of this instrument is an echelette cube. Mirrors on the classical design are replaced by stepped mirrors -integrated into that interference cube- thus suppressing any moving part. The steps' directions being set over a perpendicular axis, the overlap of both stepped mirrors creates a cluster of so-called "echelettes", each one corresponding to a different optical path difference (OPD). Hence the Fourier transform of the incoming radiance is directly imaged on a CCD array in a single acquisition. The frequency domain of the measurements is selected by an interferential filter disposed on the incoming optical path. A rotating wheel equipped with several filters allows the successive measurement of spectra around some bands of interest, i.e. O2, CO2 and CO absorption bands.

  9. First characterization of a static Fourier transform spectrometer

    Science.gov (United States)

    Lacan, A.; Bréon, F.-M.; Rosak, A.; Pierangelo, C.

    2017-11-01

    A new instrument concept for a Static Fourier Transform Spectrometer has been developed and characterized by CNES. This spectrometer is based on a Michelson interferometer concept, but a system of stepped mirrors generates all interference path differences simultaneously, without any moving parts. The instrument permits high spectral resolution measurements (≍0.1 cm-1) adapted to the sounding and the monitoring of atmospheric gases. Moreover, its overall dimensions are compatible with a micro satellite platform. The stepped mirrors are glued using a molecular bonding technique. An interference filter selects a waveband only a few nanometers wide. It limits the number of sampling points (and consequently the steps number) necessary to achieve the high resolution. The instrument concept can be optimized for the detection and the monitoring of various atmospheric constituents. CNES has developed a version whose measurements are centered on the CO2 absorption lines at 1573 nm (6357 cm-1). This model has a theoretical resolution of 40 pm (0.15 cm-1) within a 5 nm (22.5 cm-1) wide spectral window. It is aimed at the feasibility demonstration for atmospheric CO2 column measurements with a very demanding accuracy of better than 1%. Preliminary measurements indicate that, although high quality spectra are obtained, the theoretical performances are not yet achieved. We discuss the causes for the achieved performances and describe foreseen methods for their improvements.

  10. Spectrometer for cluster ion beam induced luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Ryuto, H., E-mail: ryuto@kuee.kyoto-u.ac.jp; Sakata, A.; Takeuchi, M.; Takaoka, G. H. [Photonics and Electronics Science and Engineering Center, Kyoto University, Kyoto 615-8510 (Japan); Musumeci, F. [Department of Physics and Astronomy, Catania University, Catania 95123 (Italy); INFN Laboratori Nazionali del Sud, Catania 95123 (Italy)

    2015-02-15

    A spectrometer to detect the ultra-weak luminescence originated by the collision of cluster ions on the surfaces of solid materials was constructed. This spectrometer consists of 11 photomultipliers with band-pass interference filters that can detect the luminescence within the wavelength ranging from 300 to 700 nm and of a photomultiplier without filter. The calibration of the detection system was performed using the photons emitted from a strontium aluminate fluorescent tape and from a high temperature tungsten filament. Preliminary measurements show the ability of this spectrometer to detect the cluster ion beam induced luminescence.

  11. Applied hydraulic transients

    CERN Document Server

    Chaudhry, M Hanif

    2014-01-01

    This book covers hydraulic transients in a comprehensive and systematic manner from introduction to advanced level and presents various methods of analysis for computer solution. The field of application of the book is very broad and diverse and covers areas such as hydroelectric projects, pumped storage schemes, water-supply systems, cooling-water systems, oil pipelines and industrial piping systems. Strong emphasis is given to practical applications, including several case studies, problems of applied nature, and design criteria. This will help design engineers and introduce students to real-life projects. This book also: ·         Presents modern methods of analysis suitable for computer analysis, such as the method of characteristics, explicit and implicit finite-difference methods and matrix methods ·         Includes case studies of actual projects ·         Provides extensive and complete treatment of governed hydraulic turbines ·         Presents design charts, desi...

  12. Laser method for simulating the transient radiation effects of semiconductor

    Science.gov (United States)

    Li, Mo; Sun, Peng; Tang, Ge; Wang, Xiaofeng; Wang, Jianwei; Zhang, Jian

    2017-05-01

    In this paper, we demonstrate the laser simulation adequacy both by theoretical analysis and experiments. We first explain the basic theory and physical mechanisms of laser simulation of transient radiation effect of semiconductor. Based on a simplified semiconductor structure, we describe the reflection, optical absorption and transmission of laser beam. Considering two cases of single-photon absorption when laser intensity is relatively low and two-photon absorption with higher laser intensity, we derive the laser simulation equivalent dose rate model. Then with 2 types of BJT transistors, laser simulation experiments and gamma ray radiation experiments are conducted. We found good linear relationship between laser simulation and gammy ray which depict the reliability of laser simulation.

  13. Uranium absorption study pile

    International Nuclear Information System (INIS)

    Raievski, V.; Sautiez, B.

    1959-01-01

    The report describes a pile designed to measure the absorption of fuel slugs. The pile is of graphite and comprises a central section composed of uranium rods in a regular lattice. RaBe sources and BF 3 counters are situated on either side of the center. A given uranium charge is compared with a specimen charge of about 560 kg, and the difference in absorption between the two noted. The sensitivity of the equipment will detect absorption variations of about a few ppm boron (10 -6 boron per gr. of uranium) or better. (author) [fr

  14. The VERDI fission fragment spectrometer

    International Nuclear Information System (INIS)

    Fregeau, M. O.; Brys, T.; Gamboni, T.; Geerts, W.; Oberstedt, S.; Oberstedt, A.; Borcea, R.

    2013-01-01

    The VERDI time-of-flight spectrometer is dedicated to measurements of fission product yields and of prompt neutron emission data. Pre-neutron fission-fragment masses will be determined by the double time-of-flight (TOF) technique. For this purpose an excellent time resolution is required. The time of flight of the fragments will be measured by electrostatic mirrors located near the target and the time signal coming from silicon detectors located at 50 cm on both sides of the target. This configuration, where the stop detector will provide us simultaneously with the kinetic energy of the fragment and timing information, significantly limits energy straggling in comparison to legacy experimental setup where a thin foil was usually used as a stop detector. In order to improve timing resolution, neutron transmutation doped silicon will be used. The high resistivity homogeneity of this material should significantly improve resolution in comparison to standard silicon detectors. Post-neutron fission fragment masses are obtained form the time-of-flight and the energy signal in the silicon detector. As an intermediary step a diamond detector will also be used as start detector located very close to the target. Previous tests have shown that poly-crystalline chemical vapour deposition (pCVD) diamonds provides a coincidence time resolution of 150 ps not allowing complete separation between very low-energy fission fragments, alpha particles and noise. New results from using artificial single-crystal diamonds (sCVD) show similar time resolution as from pCVD diamonds but also sufficiently good energy resolution. (authors)

  15. Progress of the BESS Superconducting Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Haino, S. E-mail: haino@icepps.s.u-tokyo.ac.jp; Abe, K.; Anraku, K.; Fuke, H.; Hams, T.; Ikeda, N.; Itasaki, A.; Izumi, K.; Kumazawa, T.; Lee, M.H.; Maeno, T.; Makida, Y.; Matsuda, S.; Matsui, N.; Matsumoto, H.; Matsumoto, K.; Mitchell, J.W.; Moiseev, A.A.; Nishimura, J.; Nozaki, M.; Omiya, H.; Orito, S.; Ormes, J.F.; Sanuki, T.; Sasaki, M.; Seo, E.S.; Shikaze, Y.; Streitmatter, R.E.; Suzuki, J.; Takasugi, Y.; Takeuchi, S.; Tanaka, K.; Taniguchi, T.; Tanizaki, K.; Yamagami, T.; Yamamoto, A.; Yamamoto, Y.; Yamato, K.; Yoshida, T.; Yoshimura, K

    2004-02-01

    Balloon-borne Experiment with a Superconducting Spectrometer (BESS) is a balloon-borne spectrometer to study elementary particle phenomena in the early Universe as well as the origin and the propagation of cosmic radiation. The instrument has a unique feature of a thin superconducting solenoid which enables a large acceptance with a cylindrical configuration. Nine balloon flights have been successfully carried out since 1993. In 2002, the detector was upgraded as the BESS-TeV spectrometer to extend primary cosmic-ray spectra up to 1 TeV. For further studies of low-energy antiprotons, a new spectrometer, BESS-Polar, with a ultra-thin superconducting solenoid is being developed for long duration balloon flights in Antarctica.

  16. Low Power FPGA Based Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to design a general purpose reconfigurable wide bandwidth spectrometer for use in NASA's passive microwave missions, deep space network and radio...

  17. Low Power Mass Spectrometer employing TOF Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A low power Mass Spectrometer employing multiple time of flight circuits for parallel processing is possible with a new innovation in design of the Time of flight...

  18. TRISP: Three axes spin echo spectrometer

    Directory of Open Access Journals (Sweden)

    Thomas Keller

    2015-12-01

    Full Text Available TRISP, operated by the Max-Planck-Institute for Solid State Research, is a high-resolution neutron spectrometer combining the three axes and neutron resonance spin echo (NRSE techniques.

  19. RITA-type triple axis spectrometers

    International Nuclear Information System (INIS)

    Roennow, H.M.

    2001-01-01

    The RITA spectrometer at Risoe National Laboratory was the first to incorporate a complete re-thinking of the neutron-path from source, through detector to analysis. Since then, other RITA-type spectrometers such as SPINS at NIST, RITA-II at PSI have been built, and several new spectrometers around the world are adapting the same philosophy. The main novelty of RITA was the introduction of a single back-end tank featuring both an analyser block with multiple individually turnable analyser blades and a 2D position sensitive detector. Several new triple-axis spectrometers are presently being built at existing and future sources, and almost all of them have learnt from the experience with RITA. (R.P.)

  20. View of the Axial Field Spectrometer

    CERN Multimedia

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  1. Computer control in a compton scattering spectrometer

    International Nuclear Information System (INIS)

    Cui Ningzhuo; Chen Tao; Gong Zhufang; Yang Baozhong; Mo Haiding; Hua Wei; Bian Zuhe

    1995-01-01

    The authors introduced the hardware and software of computer autocontrol of calibration and data acquisition in a Compton Scattering spectrometer which consists of a HPGe detector, Amplifiers and a MCA

  2. Electrostatic Spectrometer for Mars Rover Wheel

    Data.gov (United States)

    National Aeronautics and Space Administration — Develop a simple electrostatic spectrometer that can be mounted on the wheels of a Mars rover to continuously and unobtrusively determine the mineral composition and...

  3. Low Power FPGA Based Spectrometer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to design a general purpose reconfigurable wide bandwidth spectrometer for use in NASA's passive microwave missions, deep space network and radio...

  4. MGS SAMPLER THERMAL EMISSION SPECTROMETER GLOBAL TEMPERATURE

    Data.gov (United States)

    National Aeronautics and Space Administration — This archive contains Thermal Emission Spectrometer (TES) 25-micron global surface temperature data, collected during the ANS portion of the Mars Global Surveyor...

  5. Remote UV Fluorescence Lifetime Spectrometer, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this project is to develop, demonstrate, and deliver to NASA an innovative, portable, and power efficient Remote UV Fluorescence Lifetime Spectrometer...

  6. Design and construction of a NIR spectrometer

    CERN Document Server

    Barcala-Riveira, J M; Fernandez-Marron, J L; Molero-Menendez, F; Navarrete-Marin, J J; Oller-Gonzalez, J C

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs.

  7. Design and construction of a NIR spectrometer

    International Nuclear Information System (INIS)

    Barcala Riveira, J. M.; Fernandez Marron, J. L.; Alberdi Primicia, J.; Molero Menendez, F.; Navarrete Marin, J. J.; Oller Gonzalez, J. C.

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs

  8. Silicon spectrometer with a Peltier refrigerator

    International Nuclear Information System (INIS)

    Belcarz, E.; Chwaszczewska, J.; Hahn, G.; Nowicki, W.; Sawicka, B.; Skoczek, K.; Slapa, M.; Szymczak, M.

    1974-01-01

    This paper describes a spectrometer with a Si(Li) detector cooled by a Peltier refrigerator. The spectrometer is able to analyse samples of practically all most frequently encountered emitters of alpha, beta and low energy gamma radiation. The energy resolution were about 1.3-1.5 keV for 14 keV gamma radiation. The system can also operate in field conditions in the fluorescence analysis. (author)

  9. A digital control system for neutron spectrometers

    DEFF Research Database (Denmark)

    Hansen, Knud Bent; Skaarup, Per

    1968-01-01

    A description is given of the principles of a digital system used to control neutron spectrometers. The system is composed of independent functional units with the control programme stored on punched paper tape or in a computer.......A description is given of the principles of a digital system used to control neutron spectrometers. The system is composed of independent functional units with the control programme stored on punched paper tape or in a computer....

  10. Fast-response personal Moessbauer spectrometer

    International Nuclear Information System (INIS)

    Kholmetskij, A.L.; Mashlan, M.; Misevich, O.V.; Evdokimov, V.A.; Lopatik, A.R.; Zhak, D.; Fedorov, A.A.; Snashel, V.

    1995-01-01

    Spectrometer design to record transmission Moessbauer spectra is described. The spectrometer consists of PC/AT computer with 1 mb memory and 40 mb hard disk, of EPSON LX 850 printer, of color monitor with VGA graphical adapter, of data accumulation system, of speed generator, of motion system with minivibrator, of scintillation detector with YA10 3 :Ce scintillator, of single-channel amplitude analyzer, of measuring bench and of 57 Co(Rh) source. 1 ref.; 1 fig

  11. Muon momentum measurement in magnetized iron spectrometers

    International Nuclear Information System (INIS)

    Voss, R.; Zupancic, C.

    1984-01-01

    Measuring the momentum of high-energy muons with a magnetized iron spectrometer is a conventional technique employed by numerous experiments and may appear to be an old-fashioned subject. In the TeV regime, multiple scattering errors become small compared to measurement errors achieveable with large-surface particle detectors, and there are indications that new physical effects influencing the resolution properties of a muon spectrometer may become important. (orig./HSI)

  12. The BTeV main spectrometer

    International Nuclear Information System (INIS)

    Sheldon, P.D.

    2001-01-01

    BTeV is a second generation B-factory experiment that will use a double-arm, forward spectrometer in the C0 experimental hall at the Fermilab Tevatron. I will describe the motivation and design of the 'main spectrometer', consisting of a ring-imaging Cherenkov system for charged particle identification, an electromagnetic calorimeter of lead-tungstate crystals, a proportional tube muon system with magnetized filtering steel, and a straw-tube and silicon strip charged particle tracking system

  13. Ruggedized Spectrometers Are Built for Tough Jobs

    Science.gov (United States)

    2015-01-01

    The Mars Curiosity Chemistry and Camera instrument, or ChemCam, analyzes the elemental composition of materials on the Red Planet by using a spectrometer to measure the wavelengths of light they emit. Principal investigator Roger Wiens worked with Ocean Optics, out of Dunedin, Florida, to rework the company's spectrometer to operate in cold and rowdy conditions and also during the stresses of liftoff. Those improvements have been incorporated into the firm's commercial product line.

  14. Electromagnetic transients in power cables

    CERN Document Server

    da Silva, Filipe Faria

    2013-01-01

    From the more basic concepts to the most advanced ones where long and laborious simulation models are required, Electromagnetic Transients in Power Cables provides a thorough insight into the study of electromagnetic transients and underground power cables. Explanations and demonstrations of different electromagnetic transient phenomena are provided, from simple lumped-parameter circuits to complex cable-based high voltage networks, as well as instructions on how to model the cables.Supported throughout by illustrations, circuit diagrams and simulation results, each chapter contains exercises,

  15. Revisiting Absorptive Capacity

    DEFF Research Database (Denmark)

    de Araújo, Ana Luiza Lara; Ulhøi, John Parm; Lettl, Christopher

    learning processes of absorptive capacity, which comprise combinative and adaptive capabilities. Drawing on survey data (n=169), the study concludes that combinative capabilities primarily enhance transformative and exploratory learning processes, while adaptive capabilities strengthen all three learning......Absorptive capacity has mostly been perceived as a 'passive' outcome of R&D investments. Recently, however, a growing interest into its 'proactive' potentials has emerged. This paper taps into this development and proposes a dynamic model for conceptualizing the determinants of the complementary...

  16. Study of neutron spectrometers for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Kaellne, Jan

    2005-11-15

    A review is presented of the developments in the field of neutron emission spectrometry (NES) which is of relevance for identifying the role of NES diagnostics on ITER and selecting suitable instrumentation. Neutron spectrometers will be part of the ITER neutron diagnostic complement and this study makes a special effort to examine which performance characteristics the spectrometers should possess to provide the best burning plasma diagnostic information together with neutron cameras and neutron yield monitors. The performance of NES diagnostics is coupled to how much interface space can be provided which has lead to an interest to find compact instruments and their NES capabilities. This study assesses all known spectrometer types of potential interest for ITER and makes a ranking of their performance (as demonstrated or projected), which, in turn, are compared with ITER measurement requirements as a reference; the ratio of diagnostic performance to interface cost for different spectrometers is also discussed for different spectrometer types. The overall result of the study is an assessment of which diagnostic functions neutron measurements can provide in burning plasma fusion experiments on ITER and the role that NES can play depending on the category of instrument installed. Of special note is the result that much higher quality diagnostic information can be obtained from neutron measurements with total yield monitors, profile flux cameras and spectrometers when the synergy in the data is considered in the analysis and interpretation.

  17. Ion guide quadrupole mass spectrometer at Jyvaeskylae

    International Nuclear Information System (INIS)

    Iivonen, A.; Saintola, R.; Valli, K.; Morita, K.; Yoshida, A.

    1991-01-01

    A new mass analyzing device consisting of an ion guide connected to a commercial quadrupole mass spectrometer is being developed at the Department of Physics, University of Jyvaeskylae. The new spectrometer is expected to have the similar properties to the present ion guide isotope separator on-line (IGISOL): excellent stability, similar separation efficiency for all chemical elements and short separation time. This ion guide mass spectrometer (IGQMS) is schematically shown. The IGQMS differs from the IGISOL in four essential ways: a squeezer ion guide, a differential pumping section, a transport section in which an electrostatic lens system brings ions into high vacuum, and a commercial quadrupole spectrometer used in place of a magnetic separator. The entire spectrometer became operational in the summer of 1990. The tests have been done with the alpha-active Po-215 ions released from an Ac-227 source in the target chamber. The squeezer, differential pumping section, transport section and quadrupole mass spectrometer of the IGQMS are described. The results of the measured transmission yield and the total yield of Po-215 and some merits of the IGQMS are reported. (K.I.)

  18. Recent ion optics and mass spectrometers

    International Nuclear Information System (INIS)

    Matsuda, Hisashi

    1976-01-01

    The establishment of the third order approximation method for computing the orbit of the ion optical system for mass spectrometers and the completion of its computer program are reported. A feature of this orbit computation is in that the effect of the fringing field can be considered with the accuracy of third order approximation. Several new ion optical systems for mass spectrometers have been proposed by using such orbit computing programs. Brief explanation and the description on the future prospect and problems are made on the following items: the vertual image double focusing mass spectrometer, the second order double focusing mass spectrometer, the E x B superposed field mass spectrometer, and the apparatus with a cylindrical electric field and Q-lens. In the E x B superposed field with Matsuda plates, if the magnetic field is generated by an electromagnet instead of a permanent magnet, the dispersion of mass and energy can be changed at will. The Matsuda plates are known as the auxiliary electrodes positioned at the top and bottom of a cylindrical capacitor. Utilizing those characteristics, a zoom spectrometer can be made, with which only a necessary part of mass spectra can be investigated in detail, but the whole spectra are investigated roughly. In addition, the distribution of energy can be investigated simultaneously after the separation of ionic mass similarly to the parabola apparatus. (Iwakiri, K.)

  19. Moessbauer spectrometer MsAa-3

    International Nuclear Information System (INIS)

    Gornicki, R.; Blachowski, A.; Ruebenbauer, K.

    2007-01-01

    The paper is aimed at the description of the newly developed Moessbauer spectrometer MsAa-3. The spectrometer MsAa-3 consists of a high quality γ--ray spectrometer including either a proportional gas detector head or a scintillation detector head, a transducer driving system including the transducer, data storage system, and data communication system based on the TCP/IP protocol. Additionally, the Michelson-Morley interferometer is provided for precise calibration of the transducer velocity. The spectrometer is equipped with an integrated simple temperature controller. All the essential functions are remotely controlled over the TCP/IP link allowing for the spectrometer set-up as the stand-alone unit in the computer network, e.g. on the Internet. External γ-ray detectors or external complete nuclear blocks could be used as well. The spectrometer is equipped with software allowing for setting all the functions, to perform on-line control, and retrieve data. The Moessbauer data processing software MOSGRAF is enclosed as well. The latter software allows for the calculation of the variety of velocity reference functions. (authors)

  20. Absorption fluids data survey

    Science.gov (United States)

    Macriss, R. A.; Zawacki, T. S.

    Development of improved data for the thermodynamic, transport and physical properties of absorption fluids were studied. A specific objective of this phase of the study is to compile, catalog and coarse screen the available US data of known absorption fluid systems and publish it as a first edition document to be distributed to manufacturers, researchers and others active in absorption heat pump activities. The methodology and findings of the compilation, cataloguing and coarse screening of the available US data on absorption fluid properties and presents current status and future work on this project are summarized. Both in house file and literature searches were undertaken to obtain available US publications with pertinent physical, thermodynamic and transport properties data for absorption fluids. Cross checks of literature searches were also made, using available published bibliographies and literature review articles, to eliminate secondary sources for the data and include only original sources and manuscripts. The properties of these fluids relate to the liquid and/or vapor state, as encountered in normal operation of absorption equipment employing such fluids, and to the crystallization boundary of the liquid phase, where applicable. The actual data were systematically classified according to the type of fluid and property, as well as temperature, pressure and concentration ranges over which data were available. Data were sought for 14 different properties: Vapor-Liquid Equilibria, Crystallization Temperature, Corrosion Characteristics, Heat of Mixing, Liquid-Phase-Densities, Vapor-Liquid-Phase Enthalpies, Specific Heat, Stability, Viscosity, Mass Transfer Rate, Heat Transfer Rate, Thermal Conductivity, Flammability, and Toxicity.

  1. Transient measurements with an ultrafast scanning tunneling microscope on semiconductor surfaces

    DEFF Research Database (Denmark)

    Keil, Ulrich Dieter Felix; Jensen, Jacob Riis; Hvam, Jørn Märcher

    1998-01-01

    We demonstrate: the use of an ultrafast scanning tunneling microscope on a semiconductor surface. Laser-induced transient signals with 1.8 ps rise time are detected, The investigated sample is a low-temperature grown GaAs layer plated on a sapphire substrate with a thin gold layer that serves as st...... by the nonuniform carrier density created by the absorption of the light (photo Dember effect). The transient depends in sign and in shape on the direction of optical excitation. This signal is the dominating transient in tunneling mode. The signals are explained by a capacitive coupling across the tunneling gap...

  2. Absorption cooling device. Absorptions-Kuehlvorrichtung

    Energy Technology Data Exchange (ETDEWEB)

    Bourne, J.; Vardi, I.; Kimchi, Y.; Ben-Dror, J.

    1980-03-25

    The invention concerns improvements of absorption refrigerators, where a lithium chloride or lithium bromide/water cycle is used. According to the invention an inner separating or dividing structure between different functional parts of a machine of this type is provided. The structure contains two sections of wall, which are separated from one another by a suitable space, in order to achieve thermal insulation. This air space is provided with an opening in the direction towards the inside of the container and the opening is shielded to prevent the entry of liquids (in liquid or spray form).

  3. CHARACTERIZATION OF TRANSIENT PUFF EMISSIONS ...

    Science.gov (United States)

    Symposium Paper Transient puff emissions were characterized from burning carpet charges that were fed to a pilotscale rotary kiln combustor to assess the potential impact on emissions of using post-consumer carpet as an alternative fuel in cement kilns.

  4. Transient heating of moving objects

    Directory of Open Access Journals (Sweden)

    E.I. Baida

    2014-06-01

    Full Text Available A mathematical model of transient and quasistatic heating of moving objects by various heat sources is considered. The mathematical formulation of the problem is described, examples of thermal calculation given.

  5. Effects of food sample density on detecting results of HPGe γ-spectrometer

    International Nuclear Information System (INIS)

    Wan Yongliang; Tie Lieke; Zhu Xia; Liu Jinhao; Liu Mohan

    2014-01-01

    Background: According to the requirements of GB/T 16145-1995, the sample must be of the same mass density with standard source in the measurement of radiation activity with HPGe γ-ray spectrometer, but the density of the sample is hardly consistent with the standard source in laboratory. Purpose: The aim is to study the effect of the samples in different densities on measurement results. Methods: Firstly, the net count rates (n) of the six samples in various mass densities are measured using HPGe γ-ray spectrometer, and the respective self-absorption coefficients are calculated. Secondly, the sample-model is established using sourceless efficiency calibration software-Gammaclib. And then the detection efficiency and self-absorption coefficient are obtained. Results: The detection results show that with the raise of density, the self absorption coefficients are decreased. Conclusion: The results by both methods indicate that the differences of the density, between sample and standard source have obvious influences on the measurement results and need self-absorption correction. (authors)

  6. THOR Ion Mass Spectrometer (IMS)

    Science.gov (United States)

    Retinò, Alessandro

    2017-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The Ion Mass Spectrometer (IMS) onboard THOR will provide the first high-time resolution measurements of mass-resolved ions in near-Earth space, focusing on hot ions in the foreshock, shock and magnetosheath turbulent regions. These measurements are required to study how kinetic-scale turbulent fluctuations heat and accelerate different ion species. IMS will measure the full three-dimensional distribution functions of main ion species (H+, He++, O+) in the energy range 10 eV/q to 30 keV/q with energy resolution DE/E down to 10% and angular resolution down to 11.25˚ . The time resolution will be 150 ms for O+, 300 ms for He++ and ˜ 1s for O+, which correspond to ion scales in the the foreshock, shock and magnetosheath regions. Such high time resolution is achieved by mounting four identical IMS units phased by 90˚ in the spacecraft spin plane. Each IMS unit combines a top-hat electrostatic analyzer with deflectors at the entrance together with a time-of-flight section to perform mass selection. Adequate mass-per-charge resolution (M/q)/(ΔM/q) (≥ 8 for He++ and ≥ 3 for O+) is obtained through a 6 cm long Time-of-Flight (TOF) section. IMS electronics includes a fast sweeping high voltage board that is required to make measurements at high cadence. Ion detection includes Micro Channel Plates (MCPs) combined with Application-Specific Integrated Circuits (ASICs) for charge amplification and discrimination and a discrete Time-to-Amplitude Converter (TAC) to determine the ion time of flight. A processor board will be used to for ion events formatting and will interface with the Particle Processing Unit (PPU), which will perform data processing for THOR particle detectors. The IMS instrument is being designed and will be built and calibrated by an international consortium of scientific institutes from France, USA, Germany and Japan and Switzerland.

  7. Transient two-phase flow

    International Nuclear Information System (INIS)

    Hsu, Y.Y.

    1974-01-01

    The following papers related to two-phase flow are summarized: current assumptions made in two-phase flow modeling; two-phase unsteady blowdown from pipes, flow pattern in Laval nozzle and two-phase flow dynamics; dependence of radial heat and momentum diffusion; transient behavior of the liquid film around the expanding gas slug in a vertical tube; flooding phenomena in BWR fuel bundles; and transient effects in bubble two-phase flow. (U.S.)

  8. Transient stability of superconducting alternators

    International Nuclear Information System (INIS)

    Furuyama, M.; Kirtley, J.L. Jr.

    1975-01-01

    A simulation study is performed for the purpose of determining the transient stability characteristics of superconducting alternators. This simulation is compared with an equal area criterion method. It is found that superconducting machines have good transient stability characteristics, that field forcing is not particularly helpful nor necessary. It is also found that the equal area criterion is useful for computing critical clearing times, if voltage behind subtransient reactance is held constant. (U.S.)

  9. Construction of a photoelectron spectrometer of hemispherical type

    International Nuclear Information System (INIS)

    Park, C.Y.; Kim, S.K.; Lee, D.W.

    1983-01-01

    We constructed the double focusing electron spectrometer for the ultraviolet photonelectron spectroscopy(UPS). The spectrometer is hemispherical type with the high resolution power with a vaule of about 100. The efficiency of the spectrometer was examined by the thermoelectron spectroscopy and UPS of the valence band of the Pd. It is merit of the present spectrometer that is very simple and small. (Author)

  10. The LASS [Larger Aperture Superconducting Solenoid] spectrometer

    International Nuclear Information System (INIS)

    Aston, D.; Awaji, N.; Barnett, B.

    1986-04-01

    LASS is the acronym for the Large Aperture Superconducting Solenoid spectrometer which is located in an rf-separated hadron beam at the Stanford Linear Accelerator Center. This spectrometer was constructed in order to perform high statistics studies of multiparticle final states produced in hadron reactions. Such reactions are frequently characterized by events having complicated topologies and/or relatively high particle multiplicity. Their detailed study requires a spectrometer which can provide good resolution in momentum and position over almost the entire solid angle subtended by the production point. In addition, good final state particle identification must be available so that separation of the many kinematically-overlapping final states can be achieved. Precise analyses of the individual reaction channels require high statistics, so that the spectrometer must be capable of high data-taking rates in order that such samples can be acquired in a reasonable running time. Finally, the spectrometer must be complemented by a sophisticated off-line analysis package which efficiently finds tracks, recognizes and fits event topologies and correctly associates the available particle identification information. This, together with complicated programs which perform specific analysis tasks such as partial wave analysis, requires a great deal of software effort allied to a very large computing capacity. This paper describes the construction and performance of the LASS spectrometer, which is an attempt to realize the features just discussed. The configuration of the spectrometer corresponds to the data-taking on K + and K - interactions in hydrogen at 11 GeV/c which took place in 1981 and 1982. This constitutes a major upgrade of the configuration used to acquire lower statistics data on 11 GeV/c K - p interactions during 1977 and 1978, which is also described briefly

  11. The LASS (Larger Aperture Superconducting Solenoid) spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Aston, D.; Awaji, N.; Barnett, B.; Bienz, T.; Bierce, R.; Bird, F.; Bird, L.; Blockus, D.; Carnegie, R.K.; Chien, C.Y.

    1986-04-01

    LASS is the acronym for the Large Aperture Superconducting Solenoid spectrometer which is located in an rf-separated hadron beam at the Stanford Linear Accelerator Center. This spectrometer was constructed in order to perform high statistics studies of multiparticle final states produced in hadron reactions. Such reactions are frequently characterized by events having complicated topologies and/or relatively high particle multiplicity. Their detailed study requires a spectrometer which can provide good resolution in momentum and position over almost the entire solid angle subtended by the production point. In addition, good final state particle identification must be available so that separation of the many kinematically-overlapping final states can be achieved. Precise analyses of the individual reaction channels require high statistics, so that the spectrometer must be capable of high data-taking rates in order that such samples can be acquired in a reasonable running time. Finally, the spectrometer must be complemented by a sophisticated off-line analysis package which efficiently finds tracks, recognizes and fits event topologies and correctly associates the available particle identification information. This, together with complicated programs which perform specific analysis tasks such as partial wave analysis, requires a great deal of software effort allied to a very large computing capacity. This paper describes the construction and performance of the LASS spectrometer, which is an attempt to realize the features just discussed. The configuration of the spectrometer corresponds to the data-taking on K and K interactions in hydrogen at 11 GeV/c which took place in 1981 and 1982. This constitutes a major upgrade of the configuration used to acquire lower statistics data on 11 GeV/c K p interactions during 1977 and 1978, which is also described briefly.

  12. Remote laser evaporative molecular absorption spectroscopy

    Science.gov (United States)

    Hughes, Gary B.; Lubin, Philip; Cohen, Alexander; Madajian, Jonathan; Kulkarni, Neeraj; Zhang, Qicheng; Griswold, Janelle; Brashears, Travis

    2016-09-01

    We describe a novel method for probing bulk molecular and atomic composition of solid targets from a distant vantage. A laser is used to melt and vaporize a spot on the target. With sufficient flux, the spot temperature rises rapidly, and evaporation of surface materials occurs. The melted spot creates a high-temperature blackbody source, and ejected material creates a plume of surface materials in front of the spot. Molecular and atomic absorption occurs as the blackbody radiation passes through the ejected plume. Bulk molecular and atomic composition of the surface material is investigated by using a spectrometer to view the heated spot through the ejected plume. The proposed method is distinct from current stand-off approaches to composition analysis, such as Laser-Induced Breakdown Spectroscopy (LIBS), which atomizes and ionizes target material and observes emission spectra to determine bulk atomic composition. Initial simulations of absorption profiles with laser heating show great promise for Remote Laser-Evaporative Molecular Absorption (R-LEMA) spectroscopy. The method is well-suited for exploration of cold solar system targets—asteroids, comets, planets, moons—such as from a spacecraft orbiting the target. Spatial composition maps could be created by scanning the surface. Applying the beam to a single spot continuously produces a borehole or trench, and shallow subsurface composition profiling is possible. This paper describes system concepts for implementing the proposed method to probe the bulk molecular composition of an asteroid from an orbiting spacecraft, including laser array, photovoltaic power, heating and ablation, plume characteristics, absorption, spectrometry and data management.

  13. Vitamin A absorption

    International Nuclear Information System (INIS)

    Baker, S.J.

    1976-01-01

    Investigation of the absorption of vitamin A and related substances is complicated by the multiplicity of forms in which they occur in the diet and by the possibility that they may be subject to different mechanisms of absorption. Present knowledge of these mechanisms is inadequate, especially in the case of carotenoids. Numerous tests of absorption have been developed. The most common has been the biochemical measurement of the rise in plasma vitamin A after an oral dose of retinol or retinyl ester, but standardization is inadequate. Radioisotope tests based upon assay of serum or faecal activity following oral administration of tritiated vitamin A derivaties hold considerable promise, but again standardization is inadequate. From investigations hitherto performed it is known that absorption of vitamin A is influenced by several diseases, although as yet the consistency of results and the correlation with other tests of intestinal function have often been poor. However, the test of vitamin A absorption is nevertheless of clinical importance as a specialized measure of intestinal function. (author)

  14. Rapid, Time-Division Multiplexed, Direct Absorption- and Wavelength Modulation-Spectroscopy

    Directory of Open Access Journals (Sweden)

    Alexander Klein

    2014-11-01

    Full Text Available We present a tunable diode laser spectrometer with a novel, rapid time multiplexed direct absorption- and wavelength modulation-spectroscopy operation mode. The new technique allows enhancing the precision and dynamic range of a tunable diode laser absorption spectrometer without sacrificing accuracy. The spectroscopic technique combines the benefits of absolute concentration measurements using calibration-free direct tunable diode laser absorption spectroscopy (dTDLAS with the enhanced noise rejection of wavelength modulation spectroscopy (WMS. In this work we demonstrate for the first time a 125 Hz time division multiplexed (TDM-dTDLAS-WMS spectroscopic scheme by alternating the modulation of a DFB-laser between a triangle-ramp (dTDLAS and an additional 20 kHz sinusoidal modulation (WMS. The absolute concentration measurement via the dTDLAS-technique allows one to simultaneously calibrate the normalized 2f/1f-signal of the WMS-technique. A dTDLAS/WMS-spectrometer at 1.37 µm for H2O detection was built for experimental validation of the multiplexing scheme over a concentration range from 50 to 3000 ppmV (0.1 MPa, 293 K. A precision of 190 ppbV was achieved with an absorption length of 12.7 cm and an averaging time of two seconds. Our results show a five-fold improvement in precision over the entire concentration range and a significantly decreased averaging time of the spectrometer.

  15. Rapid, Time-Division Multiplexed, Direct Absorption- and Wavelength Modulation-Spectroscopy

    Science.gov (United States)

    Klein, Alexander; Witzel, Oliver; Ebert, Volker

    2014-01-01

    We present a tunable diode laser spectrometer with a novel, rapid time multiplexed direct absorption- and wavelength modulation-spectroscopy operation mode. The new technique allows enhancing the precision and dynamic range of a tunable diode laser absorption spectrometer without sacrificing accuracy. The spectroscopic technique combines the benefits of absolute concentration measurements using calibration-free direct tunable diode laser absorption spectroscopy (dTDLAS) with the enhanced noise rejection of wavelength modulation spectroscopy (WMS). In this work we demonstrate for the first time a 125 Hz time division multiplexed (TDM-dTDLAS-WMS) spectroscopic scheme by alternating the modulation of a DFB-laser between a triangle-ramp (dTDLAS) and an additional 20 kHz sinusoidal modulation (WMS). The absolute concentration measurement via the dTDLAS-technique allows one to simultaneously calibrate the normalized 2f/1f-signal of the WMS-technique. A dTDLAS/WMS-spectrometer at 1.37 μm for H2O detection was built for experimental validation of the multiplexing scheme over a concentration range from 50 to 3000 ppmV (0.1 MPa, 293 K). A precision of 190 ppbV was achieved with an absorption length of 12.7 cm and an averaging time of two seconds. Our results show a five-fold improvement in precision over the entire concentration range and a significantly decreased averaging time of the spectrometer. PMID:25405508

  16. Ice absorption features in the 5-8 mu m region toward embedded protostars

    NARCIS (Netherlands)

    Keane, JV; Tielens, AGGM; Boogert, ACA; Schutte, WA; Whittet, DCB

    We have obtained 5-8 mum spectra towards 10 embedded protostars using the Short Wavelength Spectrometer on board the Infrared Space Observatory (ISO-SWS) with the aim of studying the composition of interstellar ices. The spectra are dominated by absorption bands at 6.0 mum and 6.85 mum. The observed

  17. Time-of-flight isochronous spectrometer

    International Nuclear Information System (INIS)

    Wouters, J.M.; Vieira, D.J.; Wollnik, H.

    1985-01-01

    This report is the second in a series of progress reports describing the design and construction of the time-of-flight isochronous (TOFI) spectrometer and its associated secondary beam line. TOFI, which is being constructed jointly by INC and MP Divisions, is designed to measure in a systematic fashion the ground-state masses of the light neutron-rich nuclei with A<70 that lie far from the valley of β stability. In the past year the authors ordered all the long-lead items necessary for construction of the spectrometer and installed the first half of the secondary beam line. Furthermore, a major portion of the control system for both the spectrometer and beam line was designed and installed. This annual report briefly summarizes the current status of the spectrometer and describes in some detail the design and installation of the first half of the transport line. For a summary of the scientific goals and overall design of the TOFI spectrometer, see the 1983 Progress at LAMPF report

  18. Transient magnetoviscosity of dilute ferrofluids

    International Nuclear Information System (INIS)

    Soto-Aquino, Denisse; Rinaldi, Carlos

    2011-01-01

    The magnetic field induced change in the viscosity of a ferrofluid, commonly known as the magnetoviscous effect and parameterized through the magnetoviscosity, is one of the most interesting and practically relevant aspects of ferrofluid phenomena. Although the steady state behavior of ferrofluids under conditions of applied constant magnetic fields has received considerable attention, comparatively little attention has been given to the transient response of the magnetoviscosity to changes in the applied magnetic field or rate of shear deformation. Such transient response can provide further insight into the dynamics of ferrofluids and find practical application in the design of devices that take advantage of the magnetoviscous effect and inevitably must deal with changes in the applied magnetic field and deformation. In this contribution Brownian dynamics simulations and a simple model based on the ferrohydrodynamics equations are applied to explore the dependence of the transient magnetoviscosity for two cases: (I) a ferrofluid in a constant shear flow wherein the magnetic field is suddenly turned on, and (II) a ferrofluid in a constant magnetic field wherein the shear flow is suddenly started. Both simulations and analysis show that the transient approach to a steady state magnetoviscosity can be either monotonic or oscillatory depending on the relative magnitudes of the applied magnetic field and shear rate. - Research Highlights: →Rotational Brownian dynamics simulations were used to study the transient behavior of the magnetoviscosity of ferrofluids. →Damped and oscillatory approach to steady state magnetoviscosity was observed for step changes in shear rate and magnetic field. →A model based on the ferrohydrodynamics equations qualitatively captured the damped and oscillatory features of the transient response →The transient behavior is due to the interplay of hydrodynamic, magnetic, and Brownian torques on the suspended particles.

  19. Interpretation of Absorption Bands in Airborne Hyperspectral Radiance Data

    Directory of Open Access Journals (Sweden)

    W. David Miller

    2009-04-01

    Full Text Available It is demonstrated that hyperspectral imagery can be used, without atmospheric correction, to determine the presence of accessory phytoplankton pigments in coastal waters using derivative techniques. However, care must be taken not to confuse other absorptions for those caused by the presence of pigments. Atmospheric correction, usually the first step to making products from hyperspectral data, may not completely remove Fraunhofer lines and atmospheric absorption bands and these absorptions may interfere with identification of phytoplankton accessory pigments. Furthermore, the ability to resolve absorption bands depends on the spectral resolution of the spectrometer, which for a fixed spectral range also determines the number of observed bands. Based on this information, a study was undertaken to determine under what circumstances a hyperspectral sensor may determine the presence of pigments. As part of the study a hyperspectral imager was used to take high spectral resolution data over two different water masses. In order to avoid the problems associated with atmospheric correction this data was analyzed as radiance data without atmospheric correction. Here, the purpose was to identify spectral regions that might be diagnostic for photosynthetic pigments. Two well proven techniques were used to aid in absorption band recognition, the continuum removal of the spectra and the fourth derivative. The findings in this study suggest that interpretation of absorption bands in remote sensing data, whether atmospherically corrected or not, have to be carefully reviewed when they are interpreted in terms of photosynthetic pigments.

  20. Gastrointestinal absorption of plutonium

    International Nuclear Information System (INIS)

    Larsen, R.P.; Oldham, R.D.; Bhattacharyya, M.H.; Moretti, E.S.; Austin, D.J.

    1981-01-01

    An investigation has been made of the effect of the oxidation state of plutonium on its absorption from the gastrointestinal tract. For mice and rats that have been starved prior to gastrointestinal administration, there is no significant difference between the absorption factors for Pu(IV) and Pu(VI). The value obtained for Pu(VI) is an order of magnitude lower than that reported previously. The value obtained for Pu(IV) is two orders of magnitude higher than those reported previously for nitrate solutions and the same as those reported for citrate solutions

  1. Quantum Absorption Refrigerator

    Science.gov (United States)

    Levy, Amikam; Kosloff, Ronnie

    2012-02-01

    A quantum absorption refrigerator driven by noise is studied with the purpose of determining the limitations of cooling to absolute zero. The model consists of a working medium coupled simultaneously to hot, cold, and noise baths. Explicit expressions for the cooling power are obtained for Gaussian and Poisson white noise. The quantum model is consistent with the first and second laws of thermodynamics. The third law is quantified; the cooling power Jc vanishes as Jc∝Tcα, when Tc→0, where α=d+1 for dissipation by emission and absorption of quanta described by a linear coupling to a thermal bosonic field, where d is the dimension of the bath.

  2. Recent development of transient electronics

    Directory of Open Access Journals (Sweden)

    Huanyu Cheng

    2016-01-01

    Full Text Available Transient electronics are an emerging class of electronics with the unique characteristic to completely dissolve within a programmed period of time. Since no harmful byproducts are released, these electronics can be used in the human body as a diagnostic tool, for instance, or they can be used as environmentally friendly alternatives to existing electronics which disintegrate when exposed to water. Thus, the most crucial aspect of transient electronics is their ability to disintegrate in a practical manner and a review of the literature on this topic is essential for understanding the current capabilities of transient electronics and areas of future research. In the past, only partial dissolution of transient electronics was possible, however, total dissolution has been achieved with a recent discovery that silicon nanomembrane undergoes hydrolysis. The use of single- and multi-layered structures has also been explored as a way to extend the lifetime of the electronics. Analytical models have been developed to study the dissolution of various functional materials as well as the devices constructed from this set of functional materials and these models prove to be useful in the design of the transient electronics.

  3. Magnetic field measurements of the BLAST spectrometer

    International Nuclear Information System (INIS)

    Dow, Karen A.; Botto, Tancredi; Goodhue, Abigail; Hasell, Douglas; Loughnan, Dylan; Murphy, Kilian; Smith, Timothy Paul; Ziskin, Vitaliy

    2009-01-01

    The Bates Large Acceptance Spectrometer Toroid has been built to study nuclear physics reactions using a stored, polarized electron beam and a variety of polarized targets internal to the storage ring. The spectrometer consists of eight coils surrounding the target cell. There is a requirement of nominally zero field along the centerline of the spectrometer for proper electron beam storage. In addition, the polarized internal targets require a low field gradient in the target region. Magnetic field measurements were made near the beam centerline to guide the alignment of the coils and satisfy the field magnitude and gradient requirements. After the coils were aligned, the magnetic field was measured in the detector regions to provide information for particle tracking.

  4. SPEG: An energy loss spectrometer for GANIL

    Science.gov (United States)

    Bianchi, L.; Fernandez, B.; Gastebois, J.; Gillibert, A.; Mittig, W.; Barrette, J.

    1989-04-01

    Since July 1985, an energy loss spectrometer (SPEG) is under operation at the National Heavy Ion Laboratory (GANIL), at Caen (France). It has been designed to allow the study of quantum states populated in reactions induced by nuclei accelerated at energies up to 100 A MeV. The spectrometer has been designed by P. Birien. The optical properties and the main magnetic features have been calculated by Birien and Valero. A detailed reported of their study is given in ref. [1]. In the first part of the present paper, after recalling the specifications of the spectrometer, we shall give an overall description of the main characteristics, together with indications about the various shimming procedures which have been used to achieve the desired resolution (sections 1-4). In the second part, we shall describe various accessories and the different kinds of detectors which are used during experiments, with several illustrations of experimental results (sections 5 and 6).

  5. An EUV spectrometer for atmospheric remote sensing

    International Nuclear Information System (INIS)

    Chakrabarti, S.; Cotton, D.M.; Lampton, M.; Siegmund, O.H.W.; Link, R.

    1989-01-01

    This paper describes the Berkeley EUV Airglow Rocket Spectrometer (BEARS) experiment, designed to investigate the interactions between the solar ionizing radiation and the earth's upper atmosphere. The primary objective of this experiment is the verification the feasibility of using EUV observations as a quantitative diagnostic of the terrestrial atmosphere and its plasma environment. The expected information provided by spectroscopic measurements of EUV emission will include data on the excitation mechanisms, excitation rates, and branching ratios. The BEARS experimental package consists of a high-resolution EUV airglow spectrometer, a hydrogen Lyman-alpha photometer to measure both the solar radiations and the geocoronal emissions, and a moderate-resolution solar EUV spectrometer. In a test experiment, the instruments were carried aboard a four-stage sounding rocket to a peak altitude of about 960 km and obtained airglow spectra in the 980-1060 A range and in the 1300-1360 range. 34 refs

  6. Landsat-Swath Imaging Spectrometer Design

    Science.gov (United States)

    Mouroulis, Pantazis; Green, Robert O.; Van Gorp, Byron; Moore, Lori; Wilson, Daniel W.; Bender, Holly A.

    2015-01-01

    We describe the design of a high-throughput pushbroom imaging spectrometer and telescope system that is capable of Landsat swath and resolution while providing better than 10 nm per pixel spectral resolution. The design is based on a 3200 x 480 element x 18 µm pixel size focal plane array, two of which are utilized to cover the full swath. At an optical speed of F/1.8, the system is the fastest proposed to date to our knowledge. The utilization of only two spectrometer modules fed from the same telescope reduces system complexity while providing a solution within achievable detector technology. Predictions of complete system response are shown. Also, it is shown that detailed ghost analysis is a requirement for this type of spectrometer and forms an essential part of a complete design.

  7. A compact multichannel spectrometer for Thomson scattering.

    Science.gov (United States)

    Schoenbeck, N L; Schlossberg, D J; Dowd, A S; Fonck, R J; Winz, G R

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T(e) VPH grating and measurements T(e) > 100 eV by a 2072 l∕mm VPH grating. The spectrometer uses a fast-gated (~2 ns) ICCD camera for detection. A Gen III image intensifier provides ~45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  8. A compact multichannel spectrometer for Thomson scatteringa)

    Science.gov (United States)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R.

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of Te VPH grating and measurements Te > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated (˜2 ns) ICCD camera for detection. A Gen III image intensifier provides ˜45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  9. Prismatic analyzer concept for neutron spectrometers

    DEFF Research Database (Denmark)

    Birk, Jonas O.; Marko, M.; Freeman, P.G.

    2014-01-01

    Developments in modern neutron spectroscopy have led to typical sample sizes decreasing from few cm to several mm in diameter samples. We demonstrate how small samples together with the right choice of analyser and detector components makes distance collimation an important concept in crystal...... analyser spectrometers. We further show that this opens new possibilities where neutrons with different energies are reflected by the same analyser but counted in different detectors, thus improving both energy resolution and total count rate compared to conventional spectrometers. The technique can...... inverse geometry Time-of-flight spectrometer installed at PSI, Switzerland, and shows excellent agreement with the predictions. Typical improvements will be 2.0 times finer resolution and a factor of 1.9 in flux gain compared to a focussing Rowland geometry, or of 3.3 times finer resolution and a factor...

  10. A compact multichannel spectrometer for Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R. [Department of Engineering Physics, University of Wisconsin, Madison, Wisconsin 53706 (United States)

    2012-10-15

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T{sub e} < 100 eV are achieved by a 2971 l/mm VPH grating and measurements T{sub e} > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated ({approx}2 ns) ICCD camera for detection. A Gen III image intensifier provides {approx}45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  11. 21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer Greatly Expands Mass Spectrometry Toolbox

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, Jared B.; Lin, Tzu-Yung; Leach, Franklin E.; Tolmachev, Aleksey V.; Tolić, Nikola; Robinson, Errol W.; Koppenaal, David W.; Paša-Tolić, Ljiljana

    2016-10-12

    We provide the initial performance evaluation of a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer operating at the Environmental Molecular Sciences Laboratory at Pacific Northwest National Laboratory. The spectrometer constructed for the 21T system employs a commercial dual linear ion trap mass spectrometer coupled to a FTICR spectrometer designed and built in-house. Performance gains from moving to higher magnetic field strength are exemplified by the measurement of peptide isotopic fine structure, complex natural organic matter mixtures, and large proteins. Accurate determination of isotopic fine structure was demonstrated for doubly charged substance P with minimal spectral averaging, and 8,158 molecular formulas assigned to Suwannee River Fulvic Acid standard with RMS error of 10 ppb. We also demonstrated superior performance for intact proteins; namely, broadband isotopic resolution of the entire charge state distribution of apotransferrin (78 kDa) and facile isotopic resolution of monoclonal antibody under a variety of acquisition parameters (e.g. 6 s time-domains with absorption mode processing yielded resolution of approximately 1M at m/z =2,700).

  12. Experimental study on microlaser fluorescence spectrometer

    Science.gov (United States)

    Tian, Zhaoshuo; Wang, Ling; Zhang, Shanshan; Zhang, Yanchao; Liu, Libao; Gu, Erdan

    2018-01-01

    This paper presents a kind of miniature handheld laser fluorescence spectrometer, which integrates a laser emission system, a spectroscopic system, and a detection system into a volume of 100×50×20 mm3. A universal serial bus interface is connected to PC for data processing and spectrum display. The emitted laser wavelength is 405 nm. A spectral range is 400 to 760 nm and 2-nm optical resolution has been achieved. This spectrometer has the advantages of compact structure, small volume, high sensitivity, and low cost.

  13. Wide size range fast integrated mobility spectrometer

    Science.gov (United States)

    Wang, Jian

    2013-10-29

    A mobility spectrometer to measure a nanometer particle size distribution is disclosed. The mobility spectrometer includes a conduit and a detector. The conduit is configured to receive and provide fluid communication of a fluid stream having a charged nanometer particle mixture. The conduit includes a separator section configured to generate an electrical field of two dimensions transverse to a dimension associated with the flow of the charged nanometer particle mixture through the separator section to spatially separate charged nanometer particles of the charged nanometer particle mixture in said two dimensions. The detector is disposed downstream of the conduit to detect concentration and position of the spatially-separated nanometer particles.

  14. Upgrade of an old Raman Spectrometer

    DEFF Research Database (Denmark)

    Hansen, Susanne Brunsgaard; Berg, Rolf W.; Stenby, Erling Halfdan

    2004-01-01

    Improvement of a conventional Jeol Raman spectrometer with a single channel photo multiplier detector is described. New optical components (fibres, mirror, lens and CCD detector) have been chosen to design a high quality and easy-to-use instrument. Tests have shown that with this modified...... spectrometer Raman spectra can be acquired of a quality comparable to the spectra obtained previously, but the time needed to obtain a spectrum is markedly reduced. Selected test spectra and a simple calibration procedure to obtain the wavenumber values from the band CCD pixel position are presented....

  15. An efficient gravitational spectrometer for ultracold neutrons

    International Nuclear Information System (INIS)

    Geltenbort, P.; Goeltl, L.; Henneck, R.; Horras, M.; Kirch, K.; Knecht, A.; Lauss, B.; Meier, M.; Straumann, U.; Zsigmond, G.

    2010-01-01

    We report on the design and construction of an efficient gravitational spectrometer for ultracold neutrons. The spectrometer is suited to experiments that can greatly profit from knowledge of the neutron energy spectrum without losing available statistics, such as many of the current precision experiments that use ultracold neutrons. The description of the apparatus is complemented by the results of the first test measurements which served as a proof of principle and showed its capability of discriminating between different UCN energy ranges. The measurements showed the expected behavior and are in qualitative agreement with Monte Carlo simulations.

  16. An efficient gravitational spectrometer for ultracold neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Geltenbort, P. [Institut Laue-Langevin, Grenoble (France); Goeltl, L. [Paul Scherrer Institut, PSI, Villigen (Switzerland); ETH Zuerich, Zuerich (Switzerland); Henneck, R. [Paul Scherrer Institut, PSI, Villigen (Switzerland); Horras, M. [Paul Scherrer Institut, PSI, Villigen (Switzerland); Excellence Cluster ' Universe' , Technische Universitaet Muenchen, Garching (Germany); Kirch, K., E-mail: klaus.kirch@psi.c [Paul Scherrer Institut, PSI, Villigen (Switzerland); ETH Zuerich, Zuerich (Switzerland); Knecht, A., E-mail: a.knecht@psi.c [Paul Scherrer Institut, PSI, Villigen (Switzerland); University of Zuerich, Zuerich (Switzerland); ETH Zuerich, Zuerich (Switzerland); Lauss, B.; Meier, M. [Paul Scherrer Institut, PSI, Villigen (Switzerland); Straumann, U. [University of Zuerich, Zuerich (Switzerland); Zsigmond, G. [Paul Scherrer Institut, PSI, Villigen (Switzerland)

    2010-12-01

    We report on the design and construction of an efficient gravitational spectrometer for ultracold neutrons. The spectrometer is suited to experiments that can greatly profit from knowledge of the neutron energy spectrum without losing available statistics, such as many of the current precision experiments that use ultracold neutrons. The description of the apparatus is complemented by the results of the first test measurements which served as a proof of principle and showed its capability of discriminating between different UCN energy ranges. The measurements showed the expected behavior and are in qualitative agreement with Monte Carlo simulations.

  17. Large acceptance spectrometers for π0 mesons

    International Nuclear Information System (INIS)

    Awes, T.C.; Ferguson, R.L.; Obenshain, F.E.

    1984-01-01

    A spectrometer composed of lead-oxide loaded glass blocks has been constructed for detection of neutral pi mesons emitted in low energy heavy ion reactions. The spectrometer detects the Cerenkov radiation emitted when the high energy photons (Eγ approx. 70 MeV) resulting from π 0 decay create electron-position pairs in the glass, initiating electromagnetic showers. A geometric acceptance of better than 5% of 4π is possible; the π 0 detection efficiency varies between this value at T/sub π/ = 0 MeV and 1% for T/sub π/ approx. 100 MeV

  18. Active feedback regulation of a Michelson interferometer to achieve zero-background absorption measurements.

    Science.gov (United States)

    Lundin, Patrik; Guan, Zuguang; Svanberg, Sune

    2011-01-20

    An active phase-controlling scheme based on a proportional-integral-derivative-controlled piezoelectric transducer is presented with the purpose of stabilizing a quasi-zero-background absorption spectrometer. A fiber-based balanced Michelson interferometer is used, and absorption due to a gas sample in one of its arms results in an increased light signal to a detector, which otherwise, thanks to destructive interference, experiences a very low light level. With the presented approach, the sensitivity of already potent absorption measurement techniques, e.g., based on modulation, could be improved even further.

  19. Chemical Absorption Materials

    DEFF Research Database (Denmark)

    Thomsen, Kaj

    2011-01-01

    Chemical absorption materials that potentially can be used for post combustion carbon dioxide capture are discussed. They fall into five groups, alkanolamines, alkali carbonates, ammonia, amino acid salts, and ionic liquids. The chemistry of the materials is discussed and advantages and drawbacks...

  20. Neutron resonance absorption theory

    International Nuclear Information System (INIS)

    Reuss, P.

    1991-11-01

    After some recalls on the physics of neutron resonance absorption during their slowing down, this paper presents the main features of the theoretical developments performed by the french school of reactor physics: the effective reaction rate method so called Livolant-Jeanpierre theory, the generalizations carried out by the author, and the probability table method [fr

  1. Transient Faults in Computer Systems

    Science.gov (United States)

    Masson, Gerald M.

    1993-01-01

    A powerful technique particularly appropriate for the detection of errors caused by transient faults in computer systems was developed. The technique can be implemented in either software or hardware; the research conducted thus far primarily considered software implementations. The error detection technique developed has the distinct advantage of having provably complete coverage of all errors caused by transient faults that affect the output produced by the execution of a program. In other words, the technique does not have to be tuned to a particular error model to enhance error coverage. Also, the correctness of the technique can be formally verified. The technique uses time and software redundancy. The foundation for an effective, low-overhead, software-based certification trail approach to real-time error detection resulting from transient fault phenomena was developed.

  2. Cohabitation Duration and Transient Domesticity.

    Science.gov (United States)

    Golub, Andrew; Reid, Megan; Strickler, Jennifer; Dunlap, Eloise

    2013-01-01

    Research finds that many impoverished urban Black adults engage in a pattern of partnering and family formation involving a succession of short cohabitations yielding children, a paradigm referred to as transient domesticity. Researchers have identified socioeconomic status, cultural adaptations, and urbanicity as explanations for aspects of this pattern. We used longitudinal data from the 2001 Survey of Income and Program Participation to analyze variation in cohabitation and marriage duration by race/ethnicity, income, and urban residence. Proportional hazards regression indicated that separation risk is greater among couples that are cohabiting, below 200% of the federal poverty line, and Black but is not greater among urban dwellers. This provides empirical demographic evidence to support the emerging theory of transient domesticity and suggests that both socioeconomic status and race explain this pattern. We discuss the implications of these findings for understanding transient domesticity and make recommendations for using the Survey of Income and Program Participation to further study this family formation paradigm.

  3. Explosive and Radio-Selected Transients: Transient Astronomy with ...

    Indian Academy of Sciences (India)

    Therefore, multiwaveband observational efforts with wide fields of view will be the key to progress of transients astronomy from the middle 2020s offering unprecedented deep images and high spatial and spectral resolutions. Radio observations of Gamma Ray Bursts (GRBs) with SKA will uncover not only much fainter ...

  4. ABSORPTION MEASURE DISTRIBUTION IN Mrk 509

    Energy Technology Data Exchange (ETDEWEB)

    Adhikari, T. P.; Różańska, A.; Sobolewska, M. [Nicolaus Copernicus Astronomical Center, Polish Academy of Sciences, Bartycka 18, 00-716, Warsaw (Poland); Czerny, B., E-mail: tek@camk.edu.pl [Center for Theoretical Physics, Polish Academy of Sciences, Al. Lotnikow 32/46 02-668, Warsaw (Poland)

    2015-12-20

    In this paper we model the observed absorption measure distribution (AMD) in Mrk 509, which spans three orders of magnitude in ionization level with a single-zone absorber in pressure equilibrium. AMD is usually constructed from observations of narrow absorption lines in radio-quiet active galaxies with warm absorbers. We study the properties of the warm absorber in Mrk 509 using recently published broadband spectral energy distribution observed with different instruments. This spectrum is an input in radiative transfer computations with full photoionization treatment using the titan code. We show that the simplest way to fully reproduce the shape of AMD is to assume that the warm absorber is a single zone under constant total pressure. With this assumption, we found theoretical AMD that matches the observed AMD determined on the basis of the 600 ks reflection grating spectrometer XMM-Newton spectrum of Mrk 509. The softness of the source spectrum and the important role of the free–free emission breaks the usual degeneracy in the ionization state calculations, and the explicit dependence of the depths of AMD dips on density open a new path to the density diagnostic for the warm absorber. In Mrk 509, the implied density is of the order of 10{sup 8} cm{sup −3}.

  5. Transient analysis of multicavity klystrons

    International Nuclear Information System (INIS)

    Lavine, T.L.; Miller, R.H.; Morton, P.L.; Ruth, R.D.

    1988-09-01

    We describe a model for analytic analysis of transients in multicavity klystron output power and phase. Cavities are modeled as resonant circuits, while bunching of the beam is modeled using linear space-charge wave theory. Our analysis has been implemented in a computer program which we use in designing multicavity klystrons with stable output power and phase. We present as examples transient analysis of a relativistic klystron using a magnetic pulse compression modulator, and of a conventional klystron designed to use phase shifting techniques for RF pulse compression. 4 refs., 4 figs

  6. Hybrid plasmon photonic crystal resonance grating for integrated spectrometer biosensor.

    Science.gov (United States)

    Guo, Hong; Guo, Junpeng

    2015-01-15

    Using nanofabricated hybrid metal-dielectric nanohole array photonic crystal gratings, a hybrid plasmonic optical resonance spectrometer biosensor is demonstrated. The new spectrometer sensor technique measures plasmonic optical resonance from the first-order diffraction rather than via the traditional method of measuring optical resonance from transmission. The resonance spectra measured with the new spectrometer technique are compared with the spectra measured using a commercial optical spectrometer. It is shown that the new optical resonance spectrometer can be used to measure plasmonic optical resonance that otherwise cannot be measured with a regular optical spectrometer.

  7. Fast infrared array spectrometer with a thermoelectrically cooled 160-element PbSe detector

    International Nuclear Information System (INIS)

    Ji Jun; Gore, Jay P.; Sivathanu, Yudaya R.; Lim, Jongmook

    2004-01-01

    A fast infrared array spectrometer (FIAS) with a thermoelectrically cooled 160-element PbSe detector was demonstrated using measurements of instantaneous infrared radiation intensities simultaneously over the 1.8-4.9 μm wavelength range at a sampling rate of 390 Hz. A three-point second-degree Lagrange interpolation polynomial was constructed to calibrate the FIAS because of the nonlinear response of the infrared array detector to the incident radiation beam. This calibration method gave excellent measurements of blackbody radiation spectra except for a narrow band at wavelength of 4.3 μm due to absorption by room carbon dioxide, which is one of the two major gas radiation peaks (2.7 and 4.3 μm) from the lean premixed hydrocarbon/air combustion products in the midinfrared spectrum. Therefore, the absorption coefficient of room carbon dioxide was conveniently measured on site with the blackbody reference source, and was used in the calibration of the FIAS and also in the calculations of the radiation spectra. Blackbody tests showed that this procedure was effective in correcting for the room carbon dioxide absorption in the radiation spectra measured by the FIAS. For an example of its application, the calibrated FIAS was used to measure spectral radiation intensities from three lean premixed laminar flames and a premixed turbulent jet flame for which reference data with a grating spectrometer were available for comparison. The agreement between the FIAS measurements and the reference data was excellent

  8. Triple-axis spectrometer DruechaL

    International Nuclear Information System (INIS)

    Buehrer, W.; Keller, P.

    1996-01-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs

  9. Neutron spectrometer using NE218 liquid scintillator

    International Nuclear Information System (INIS)

    Dance, J.B.; Francois, P.E.

    1976-01-01

    A neutron spectrometer has been constructed using NE218 liquid scintillator. Discrimination against electron-gamma events was obtained usng a charge-comparison pulse shape discrimination system. The resolution obtained was about 0.25 MeV F.W.H.M. at 2.0 MeV

  10. L G Smith's RF mass spectrometer

    International Nuclear Information System (INIS)

    Koets, E.

    1981-01-01

    From 1948 on Lincoln G Smith developed mass spectrometers based on time and frequency measurements. With his last machine he obtained an accuracy of the order of 1 to 10 9 . After his untimely death in 1972 his unique instrument was moved to Delft, where its development is carried on. (author)

  11. Triple-axis spectrometer DruechaL

    Energy Technology Data Exchange (ETDEWEB)

    Buehrer, W.; Keller, P. [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland)

    1996-11-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs.

  12. Advanced Laboratory NMR Spectrometer with Applications.

    Science.gov (United States)

    Biscegli, Clovis; And Others

    1982-01-01

    A description is given of an inexpensive nuclear magnetic resonance (NMR) spectrometer suitable for use in advanced laboratory courses. Applications to the nondestructive analysis of the oil content in corn seeds and in monitoring the crystallization of polymers are presented. (SK)

  13. A 'tiny-orange' spectrometer for electrons

    International Nuclear Information System (INIS)

    Silva, N.C. da.

    1990-01-01

    An tiny-orange electron spectrometer was designed and constructed using flat permanent magnets and a surface barrier detector. The transmission functions of different system configurations were determined for energies in the 200-1100 KeV range. A mathematical model for the system was developed. (L.C.J.A.)

  14. Imaging mass spectrometer with mass tags

    Science.gov (United States)

    Felton, James S.; Wu, Kuang Jen; Knize, Mark G.; Kulp, Kristen S.; Gray, Joe W.

    2010-06-01

    A method of analyzing biological material by exposing the biological material to a recognition element, that is coupled to a mass tag element, directing an ion beam of a mass spectrometer to the biological material, interrogating at least one region of interest area from the biological material and producing data, and distributing the data in plots.

  15. Design of radial neutron spectrometer for ITER

    International Nuclear Information System (INIS)

    Nishitani, Takeo; Kasai, Satoshi; Iguchi, Tetsuo; Ebisawa, Katsuyuki; Kita, Yoshio.

    1996-09-01

    We designed the radial neutron spectrometer using a new type DT neutron spectrometer base on a recoil proton counter-telescope technique aiming ion temperature measurement for ITER. The neutron spectrometer will be installed on the well-collimated neutron beam line. A large-area recoil proton emitter is placed in parallel to the incident neutron beam and a micro-channel collimating plates are inserted between the radiator and the recoil proton detectors away from the neutron beam in order to limit the scattering angle of protons to the proton detectors. Here a very thin polyethylene film and a silicon surface barrier detector are employed as the radiator and proton detector, respectively. The energy resolution and detection efficiency are estimated to be 2.5% and 1x10 -5 counts/(n/cm 2 ), respectively for DT neutron through Monte Carlo calculations. Five units of the spectrometers will be installed just out side the bio-shield and consist a fun array using penetrations inside the bio-shield and a pre-collimator in the horizontal port. The life time of the proton detectors is estimated to be about one year in the Basic Performance Phase of ITER by neutron transport calculations using MCNP Monte Carlo code. The necessary R and D items and the design work were identified. (author)

  16. Calibration method for ion mobility spectrometer

    International Nuclear Information System (INIS)

    Vasiliev, Valery

    2011-01-01

    The new method for the calibration of the ion mobility spectrometer has been developed. This article describes the working principle, advantages and disadvantages of the calibration method operating in the mode of explosives detection. This method is most suitable for use in portable detectors, due to the small weight, small size parameters and low power consumption.

  17. A superheterodyne spectrometer for electronic paramagnetic. Resonance

    International Nuclear Information System (INIS)

    Laffon, J.L.

    1963-12-01

    After a few generalities about electron paramagnetic resonance, a consideration of different experimental techniques authorises the choice of a particular type of apparatus. An EPR superheterodyne spectrometer built in the laboratory and having a novel circuit is described in detail. With this apparatus, many experimental results have been obtained and some of these are described as example. (author) [fr

  18. Diagnosing transient plasma status: from solar atmosphere to tokamak divertor

    International Nuclear Information System (INIS)

    Giunta, A.S.; Henderson, S.; O'Mullane, M.; Summers, H.P.; Harrison, J.; Doyle, J.G.

    2016-01-01

    This work strongly exploits the interdisciplinary links between astrophysical (such as the solar upper atmosphere) and laboratory plasmas (such as tokamak devices) by sharing the development of a common modelling for time-dependent ionisation. This is applied to the interpretation of solar flare data observed by the UVSP (Ultraviolet Spectrometer and Polarimeter), on-board the Solar Maximum Mission and the IRIS (Interface Region Imaging Spectrograph), and also to data from B2-SOLPS (Scrape Off Layer Plasma Simulations) for MAST (Mega Ampère Spherical Tokamak) Super-X divertor upgrade. The derived atomic data, calculated in the framework of the ADAS (Atomic Data and Analysis Structure) project, allow equivalent prediction in non-stationary transport regimes and transients of both the solar atmosphere and tokamak divertors, except that the tokamak evolution is about one thousand times faster.

  19. Spatial mapping of greenhouse gases using laser absorption spectrometers at local scales of interest

    Energy Technology Data Exchange (ETDEWEB)

    Dobler, Jeremy

    2015-09-22

    This presentation provides and overview of the development off the GreenLITE system for spatial mapping of atmospheric CO2. The original system was developed for supporting MRV activities for ground carbon storage facilities and has since been expanded to cover larger areas and other applications.

  20. Highly efficient angularly resolving x-ray spectrometer optimized for absorption measurements with collimated sources

    Czech Academy of Sciences Publication Activity Database

    Šmíd, Michal; Gonzalez, I.G.; Ekerfelt, H.; Svensson, J.B.; Hansson, M.; Wood, I. C.; Persson, A.; Mangles, S.P.D.; Lundh, O.; Falk, Kateřina

    2017-01-01

    Roč. 88, č. 6 (2017), s. 1-8, č. článku 063102. ISSN 0034-6748 R&D Projects: GA MŠk EF15_008/0000162; GA MŠk LQ1606 EU Projects: European Commission(XE) 654148 - LASERLAB-EUROPE Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 Keywords : acceleration * measurments * x ray * high energy Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 1.515, year: 2016

  1. MOBILE ATOMIC ABSORPTION SPECTROMETER OPERATED BY PACE ENVIRONMENTAL FOR METALS-CONTAMINATED SOIL CHARACTERIZATION

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA), through the Environmental Technology Verification Program, is working to accelerate the acceptance and use of innovative technologies that improve the way the United States manages its environmental problems. This report describes ...

  2. Fuel rod behaviour during transients

    International Nuclear Information System (INIS)

    Hughes, H.; Haste, T.J.; Cameron, R.F.; Sinclair, J.E.

    1982-04-01

    The fuel pin performance code SLEUTH, the transient codes FRAP-T5 and TRAFIC and the clad deformation code CANSWEL-2 are described. It is shown how the codes treat gas release, pin cooling, cladding deformation and interaction, gap conductance etc. The materials properties used are indicated. (author)

  3. Charging transient in polyvinyl formal

    Indian Academy of Sciences (India)

    Unknown

    401–406. © Indian Academy of Sciences. 401. Charging transient in polyvinyl formal. P K KHARE*, P L JAIN† and R K PANDEY‡. Department of Postgraduate Studies & Research in Physics & Electronics, Rani Durgavati University,. Jabalpur 482 001, India. †Department of Physics, Government PG College, Damoh 470 ...

  4. Transient interactions between photosynthetic proteins

    NARCIS (Netherlands)

    Hulsker, Rinske

    2008-01-01

    The biological processes that are the basis of all life forms are mediated largely by protein-protein interactions. The protein complexes involved in these interactions can be categorised by their affinity, which results in a range from static to transient complexes. Electron transfer complexes,

  5. Simulation Model of a Transient

    DEFF Research Database (Denmark)

    Jauch, Clemens; Sørensen, Poul; Bak-Jensen, Birgitte

    2005-01-01

    This paper describes the simulation model of a controller that enables an active-stall wind turbine to ride through transient faults. The simulated wind turbine is connected to a simple model of a power system. Certain fault scenarios are specified and the turbine shall be able to sustain operati...

  6. Transient anisotropic magnetic field calculation

    International Nuclear Information System (INIS)

    Jesenik, Marko; Gorican, Viktor; Trlep, Mladen; Hamler, Anton; Stumberger, Bojan

    2006-01-01

    For anisotropic magnetic material, nonlinear magnetic characteristics of the material are described with magnetization curves for different magnetization directions. The paper presents transient finite element calculation of the magnetic field in the anisotropic magnetic material based on the measured magnetization curves for different magnetization directions. For the verification of the calculation method some results of the calculation are compared with the measurement

  7. Transient filament stretching rheometer II

    DEFF Research Database (Denmark)

    Kolte, Mette Irene; Rasmussen, Henrik K.; Hassager, Ole

    1997-01-01

    The Lagrangian sspecification is used to simulate the transient stretching filament rheometer. Simulations are performed for dilute PIB-solutions modeled as a four mode Oldroyd-B fluid and a semidilute PIB-solution modeled as a non-linear single integral equation. The simulations are compared...

  8. Laser-induced absorption and fluorescence studies of photochromic Schiff bases

    DEFF Research Database (Denmark)

    Kownacki, K.; Mordzinski, A.; Wilbrandt, R.

    1994-01-01

    Three photochromic Schiff bases: N-salicylideneaniline (SA), N-salicylidene-1-naphthylamine (SN), and N,N-bis-(salicylidene)-p-phenylenediamine (Bsp), were studied in acetonitrile by means of steady-state and time-resolved absorption and fluorescence spectroscopy, as well as semiempirical quantum...... chemical calculations. In all these molecules, the transient absorption and two-step laser-induced fluorescence spectra of long-lived transients are remarkably similar. The photochromic species is tentatively assigned to the non-hydrogen bonded form of the proton transfer reaction product...

  9. Absorptive Capacity and Diversity

    DEFF Research Database (Denmark)

    Kristinsson, Kári

    international business, organizational economics, strategic management, technology management and last but not least neo-Schumpeterian economics. The goal of this dissertation is to examine what many consider as neglected arguments from the work by Cohen and Levinthal and thereby illuminate an otherwise......One of the most influential contributions to neo-Schumpeterian economics is Cohen and Levinthal‘s papers on absorptive capacity. Since their publication in the late 1980s and early 1990s the concept absorptive capacity has had substantial impact on research in economics and management, including...... overlooked area of research. Although research based on Cohen and Levinthal‘s work has made considerable impact, there is scarcity of research on certain fundamental points argued by Cohen and Levinthal. Among these is the importance of employee diversity as well as the type and nature of interaction between...

  10. Sound absorption of snow

    OpenAIRE

    Maysenhölder, W.; Schneebeli, M.; Zhou, X.; Zhang, T.; Heggli, M.

    2008-01-01

    Recently fallen snow possesses good sound-absorbing properties. This fact is well-known and confirmed by measurements. Is the filigree structure of snowflakes decisive? In principle we know that the sound-absorbing capacity of a porous material is dependent on its structure. But until now the question as to which structural characteristics are significant has been insufficiently answered. Detailed investigations of snow are to explain this fact by precise measurements of the sound absorption,...

  11. Iron absorption studies

    International Nuclear Information System (INIS)

    Ekenved, G.

    1976-01-01

    The main objective of the present work was to study iron absorption from different iron preparations in different types of subjects and under varying therapeutic conditions. The studies were performed with different radioiron isotope techniques and with a serum iron technique. The preparations used were solutions of ferrous sulphate and rapidly-disintegrating tablets containing ferrous sulphate, ferrous fumarate and ferrous carbonate and a slow-release ferrous sulphate tablet of an insoluble matrix type (Duroferon Durules). The serum iron method was evaluated and good correlation was found between the serum iron response and the total amount of iron absorbed after an oral dose of iron given in solution or in tablet form. New technique for studying the in-vivo release properties of tablets was presented. Iron tablets labelled with a radio-isotope were given to healthy subjects. The decline of the radioactivity in the tablets was followed by a profile scanning technique applied to different types of iron tablets. The release of iron from the two types of tablets was shown to be slower in vivo than in vitro. It was found that co-administration of antacids and iron tablets led to a marked reduction in the iron absorption and that these drugs should not be administered sumultaneously. A standardized meal markedly decreased the absorbability of iron from iron tablets. The influence of the meal was more marked with rapidly-disintegrating than with slow-release ferrous sulphate tablets. The absorption from rapidly-disintegrating and slow-release ferrous sulphate tablets was compared under practical clinical conditions during an extended treatment period. The studies were performed in healthy subjects, blood donors and patients with iron deficiency anaemia and it was found that the absorption of iron from the slow-release tablets was significantly better than from the rapidly-disintegrating tablets in all three groups of subjects. (author)

  12. Total Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Rubio, B.; Gelletly, W.

    2007-01-01

    The problem of determining the distribution of beta decay strength (B(GT)) as a function of excitation energy in the daughter nucleus is discussed. Total Absorption Spectroscopy is shown to provide a way of determining the B(GT) precisely. A brief history of such measurements and a discussion of the advantages and disadvantages of this technique, is followed by examples of two recent studies using the technique. (authors)

  13. [Transient amnesia in the elderly].

    Science.gov (United States)

    Sellal, François

    2006-03-01

    The two main aetiologies of transient amnesia in the elderly are idiopathic transient global amnesia (TGA) and iatrogenic or toxic amnesia. Vascular and epileptic amnesia are less common. According to the literature, transient psychogenic amnesia, which is a frequent cause of amnesia at age 30 to 50, is very rare in the elderly. TGA is the prototypical picture of transient amnesia. It occurs more often after age 50, with no identified cause, even if some authors accept emotional stress or minor head trauma as occasional precipitants. The mechanism of TGA remains a matter of discussion. It may be the consequence of a spreading depression similar to that described in migraine with aura, but other arguments support an ischemic mechanism. Iatrogenic amnesias are mainly caused by benzodiazepines (BZs) or anticholinergics. The former may occur in a non-anxious subject, who is not a usual consumer of BZ and takes a single dose. The latter are more often due to a hypersensitivity to anticholinergic drugs, in particular in patients presenting with a covert, incipient Alzheimer's disease. A vascular origin must be considered when amnesia is accompanied by other neurological symptoms, and when the regression of the amnesic disorder is slow, lasting several days. It results from lesions involving various mechanisms and locations, mainly subcortical. Partial seizures, most often mesio-temporal, more rarely frontal, may be the cause of transient amnesia in the elderly, in the absence of a past history of epilepsy. The red flag supportive of an epileptic origin is the repetition of stereotyped amnesic episodes. EEG demonstration of seizures may be difficult and the response to antiepileptic drugs effective on partial seizures is usually good.

  14. Relic Neutrino Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Eberle, b

    2004-01-28

    Resonant annihilation of extremely high-energy cosmic neutrinos on big-bang relic anti-neutrinos (and vice versa) into Z-bosons leads to sizable absorption dips in the neutrino flux to be observed at Earth. The high-energy edges of these dips are fixed, via the resonance energies, by the neutrino masses alone. Their depths are determined by the cosmic neutrino background density, by the cosmological parameters determining the expansion rate of the universe, and by the large redshift history of the cosmic neutrino sources. We investigate the possibility of determining the existence of the cosmic neutrino background within the next decade from a measurement of these absorption dips in the neutrino flux. As a by-product, we study the prospects to infer the absolute neutrino mass scale. We find that, with the presently planned neutrino detectors (ANITA, Auger, EUSO, OWL, RICE, and SalSA) operating in the relevant energy regime above 10{sup 21} eV, relic neutrino absorption spectroscopy becomes a realistic possibility. It requires, however, the existence of extremely powerful neutrino sources, which should be opaque to nucleons and high-energy photons to evade present constraints. Furthermore, the neutrino mass spectrum must be quasi-degenerate to optimize the dip, which implies m{sub {nu}} 0.1 eV for the lightest neutrino. With a second generation of neutrino detectors, these demanding requirements can be relaxed considerably.

  15. Linear and nonlinear absorption properties of diamond-like carbon doped with cu nanoparticles

    DEFF Research Database (Denmark)

    Tamulevičius, Sigitas; Peckus, Domantas; Tamulevičius, Tomas

    2017-01-01

    Ultrafast relaxation processes in diamond-like carbon (DLC) thin films with embedded Cu nanoparticles (DLC:Cu nanocomposites) were investigated by means of transient absorption spectroscopy focusing on localized surface plasmon resonance (LSPR) of photoexcited Cu nanoparticles. Absorption spectra...... of the composite films correspond to the sum of absorption spectra of DLC matrix and Cu nanoparticles; however, Cu nanoparticles strongly dominate in the transient differential absorption. Excitations of DLC matrix and of Cu nanoparticles relax independently revealing no strong interaction. High sensitivity...... measurements enabled to obtain the hot electron relaxation dynamics in Cu nanoparticles in the low excitation intensity conditions. The relaxation time was found to be independent of the excitation intensity up to tens of microjoule per square centimeter per pulse and to increase at higher intensities...

  16. Monitoring Of The Middle Atmosphere: Grille Spectrometer Experiment Results On Board SPACELAB 1 And Scientific Program Of ATLAS 1 Mission

    Science.gov (United States)

    Papineau, N.; Camy-Peyret, C.; Ackerman, Marcel E.

    1989-10-01

    Measurements of atmospheric trace gases have been performed during the first Spacelab mission on board the Space Shuttle. The principle of the observations is infrared absorption spectroscopy using the solar occultation technique. Infrared absorption spectra of NO, CO, CO2, NO2, N20, CH4 and H2O have been recorded using the Grille spectrometer developped by ONERA and IASB. From the observed spectra, vertical profiles for these molecules have been derived. The present paper summarizes the main results and compares them with computed vertical profiles from a zonally averaged model of the middle atmosphere. The scientific objectives of the second mission, Atlas 1, planned for 1990 are also presented.

  17. SuperSpec: A Revolutionary New Spectrometer for Submillimeter Astronomy

    Data.gov (United States)

    National Aeronautics and Space Administration — SuperSpec is a new spectrometer for submm astronomy. SuperSpec stands out from other submm spectrometers in that the detectors are coupled to a series of resonant...

  18. Temperature dependence of the ClONO{sub 2} UV absorption spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Burkholder, J.B.; Talukdar, R.K.; Ravishankara, A.R. [Univ. of Colorado, Boulder, CO (United States)

    1994-04-01

    The temperature dependence of the ClONO{sub 2} absorption spectrum has been measured between 220 and 298 K and between 195 and 430 nm using a diode array spectrometer. The absorption cross sections were determined using both: (1) absolute pressure measurements at 296 K and (2) measurements at various temperatures relative to 296 K using a dual absorption cell arrangement. The temperature dependence of the ClONO{sub 2} absorption spectrum shows very broad structure. The amplitude of the temperature dependence relative to that at 296 K is weak at short wavelengths, < 2% at 215 nm and 220 K, but significant at the wavelengths important in the stratosphere, {approximately} 30% at 325 nm and 220 K. The authors ClONO{sub 2} absorption cross section data are in good general agreement with the previous measurements of Molina and Molina.

  19. Temperature dependence of the ClONO2 UV absorption spectrum

    Science.gov (United States)

    Burkholder, James B.; Talukdar, Ranajit K.; Ravishankara, A. R.

    1994-01-01

    The temperature dependence of the ClONO2 absorption spectrum has been measured between 220 and 298 K and between 195 and 430 nm using a diode array spectrometer. The absorption cross sections were determined using both: (1) absolute pressure measurements at 296 K and (2) measurements at various temperatures relative to 296 K using a dual absorption cell arrangement. The temperature dependence of the ClONO2 absorption spectrum shows very broad structure. The amplitude of the temperature dependence relative to that at 296 K is weak at short wavelengths, less than 2% at 215 nm and 220 K, but significant at the wavelengths important in the stratosphere, about 30% at 325 nm and 220 K. Our ClONO2 absorption cross section data are in good general agreement with the previous measurements of Molina and Molina (1979).

  20. High-performance dispersive Raman and absorption spectroscopy as tools for drug identification

    Science.gov (United States)

    Pawluczyk, Olga; Andrey, Sam; Nogas, Paul; Roy, Andrew; Pawluczyk, Romuald

    2009-02-01

    Due to increasing availability of pharmaceuticals from many sources, a need is growing to quickly and efficiently analyze substances in terms of the consistency and accuracy of their chemical composition. Differences in chemical composition occur at very low concentrations, so that highly sensitive analytical methods become crucial. Recent progress in dispersive spectroscopy with the use of 2-dimensional detector arrays, permits for signal integration along a long (up to 12 mm long) entrance slit of a spectrometer, thereby increasing signal to noise ratio and improving the ability to detect small concentration changes. This is achieved with a non-scanning, non-destructive system. Two different methods using P&P Optica high performance spectrometers were used. High performance optical dispersion Raman and high performance optical absorption spectroscopy were employed to differentiate various acetaminophen-containing drugs, such as Tylenol and other generic brands, which differ in their ingredients. A 785 nm excitation wavelength was used in Raman measurements and strong Raman signals were observed in the spectral range 300-1800 cm-1. Measurements with the absorption spectrometer were performed in the wavelength range 620-1020 nm. Both Raman and absorption techniques used transmission light spectrometers with volume phase holographic gratings and provided sufficient spectral differences, often structural, allowing for drug differentiation.

  1. Absorption dynamics and delay time in complex potentials

    Science.gov (United States)

    Villavicencio, Jorge; Romo, Roberto; Hernández-Maldonado, Alberto

    2018-05-01

    The dynamics of absorption is analyzed by using an exactly solvable model that deals with an analytical solution to Schrödinger’s equation for cutoff initial plane waves incident on a complex absorbing potential. A dynamical absorption coefficient which allows us to explore the dynamical loss of particles from the transient to the stationary regime is derived. We find that the absorption process is characterized by the emission of a series of damped periodic pulses in time domain, associated with damped Rabi-type oscillations with a characteristic frequency, ω = (E + ɛ)/ℏ, where E is the energy of the incident waves and ‑ɛ is energy of the quasidiscrete state of the system induced by the absorptive part of the Hamiltonian; the width γ of this resonance governs the amplitude of the pulses. The resemblance of the time-dependent absorption coefficient with a real decay process is discussed, in particular the transition from exponential to nonexponential regimes, a well-known feature of quantum decay. We have also analyzed the effect of the absorptive part of the potential on the dynamical delay time, which behaves differently from the one observed in attractive real delta potentials, exhibiting two regimes: time advance and time delay.

  2. Spectroscopic absorption measurement of a low-Z plasma

    International Nuclear Information System (INIS)

    Yang Jiamin; Ding Yaonan; Yan Jun; Zheng Zhijan; Li Jiaming; Zhang Baohan; Yang Guohong; Zhang Wenhai; Wang Yaomei

    2002-01-01

    Low-Z plasmas have been produced by x-ray radiative heating of a low-Z sample on the 'Xingguang II' laser facility. High-resolution transmission spectra of the low-Z plasma (CHO) have been measured by using a flat field grating spectrometer. Absorption lines of oxygen and carbon ions in the region from 1.6 nm to 5.0 nm have been observed clearly and identified. The unresolved transition array model (UTA) has been introduced to calculate the transmission spectra of the CHO plasma. The measured transmission spectra have been compared with the calculated ones and the results of other works

  3. The TRIUMF low energy pion spectrometer and channel

    International Nuclear Information System (INIS)

    Sobie, R.J.; Drake, T.E.; Barnett, B.M.; Erdman, K.L.; Gyles, W.; Johnson, R.R.; Roser, H.W.; Tacik, R.; Blackmore, E.W.; Gill, D.R.

    1983-08-01

    A low energy pion spectrometer has been developed for use with the TRIUMF M13 pion channel. The combined channel and spectrometer resolution is presently 1.1 MeV at T = 50 MeV. This is limited by the amount of gas and detector material in the spectrometer in addition to the inherent resolution of the channel. Improvements to both the spectrometer and channel are discussed

  4. Hardware of automation systems of isotope mass spectrometers

    International Nuclear Information System (INIS)

    Manojlov, V.V.; Meleshkin, A.S.; Novikov, L.V.; Kornil'ev, S.O.; Voronin, B.M.

    1997-01-01

    The modernized hardware of isotope mass spectrometers is described. The modern control systems for the mass spectrometers are fulfilled on the basis of IBM/PC AT. Versions of subsystems mass spectrometer control through a standard bus and through a digital-to-analog converter are considered. The characteristics of an electrometric amplifier and interface cards developed for modernized automation systems of the isotope mass spectrometers are presented

  5. Miniature anastigmatic spectrometer design with a concave toroidal mirror.

    Science.gov (United States)

    Dong, Jianing; Chen, He; Zhang, Yinchao; Chen, Siying; Guo, Pan

    2016-03-01

    An advanced optical design for a low-cost and astigmatism-corrected spectrometer with a high resolution is presented. The theory and method of astigmatism correction are determined with the use of a concave toroidal mirror. The performances of a modified spectrometer and a traditional spectrometer are compared, and the analysis is verified. Experimentally, the limiting resolution of our spectrometer is 0.1 nm full width at half-maximum, as measured for 579.1 nm.

  6. A design study of VOR: A versatile optimal resolution chopper spectrometer for the ESS

    Directory of Open Access Journals (Sweden)

    Deen P.P.

    2015-01-01

    Full Text Available VOR, the versatile optimal resolution chopper spectrometer, is designed to probe dynamic phenomena that are currently inaccessible for inelastic neutron scattering due to flux limitations. VOR is a short instrument by the standards of the European Spallation Source (ESS, 30.2 m moderator to sample, and provides instantaneous access to a broad dynamic range, 1–120 meV within each ESS period. The short instrument length combined with the long ESS pulse width enables a quadratic flux increase, even at longer wavelengths, by relaxing energy resolution from ΔE/E = 1% up to ΔE/E = 7%. This is impossible both on a long chopper spectrometer at the ESS and with instruments at short pulsed sources. In comparison to current day chopper spectrometers, VOR can offer an order of magnitude improvement in flux for equivalent energy resolutions, ΔE/E = 1–3%. Further relaxing the energy resolution enables VOR to gain an extra order of magnitude in flux. In addition, VOR has been optimised for repetition rate multiplication (RRM and is therefore able to measure, in a single ESS period, 6–14 incident wavelengths, across a wavelength band of 9 Å with a novel chopper configuration that transmits all incident wavelengths with equivalent counting statistics. The characteristics of VOR make it a unique instrument with capabilities to access small, limited-lifetime samples and transient phenomena with inelastic neutron scattering.

  7. Magneto absorption measurements of nano-size ɛ-AlxFe2-xO3 powder materials at millimeter wavelengths

    Science.gov (United States)

    Afsar, Mohammed N.; Li, Zijing; Korolev, Konstantin A.; Namai, Asuka; Ohkoshi, Shin-ichi

    2011-04-01

    Ferromagnetic absorption spectra of ɛ-AlxFe2-xO3 powders with various x parameters and densities were obtained using free space quasi-optical spectrometer. Two absorption peaks located at around 95 and 105 GHz have been found. The 95 GHz absorption corresponds to x parameter value of 0.66; while the 105 GHz absorption corresponds to x-parameter value of 0.49. The absorption peak shifts to the lower frequency with increasing value of x parameter. The change in densities resulted in change in absorption intensity. The absorption characteristics are repeatable for these specimens prepared even at eight months interval. These absorbers are composed of ɛ-AlxFe2-xO3 nanomagnets and prepared by sol-gel techniques. Free space quasi-optical spectrometer equipped with a set of tunable backward-wave oscillators as power sources is used in this work to study the transmittance and absorption property of this series of materials at millimeter wave frequencies. The transmittance and absorbance spectra of ɛ-AlxFe2-xO3 powders with different x values (x = 0.66 and 0.49) and densities are recorded using the free space spectrometer. Strong magnetic absorption centering at 95 GHz (corresponding to x = 0.66) and at 105 GHz (x = 0.49) are found for all densities.

  8. Differentially pumped dual linear quadrupole ion trap mass spectrometer

    Science.gov (United States)

    Owen, Benjamin C.; Kenttamaa, Hilkka I.

    2015-10-20

    The present disclosure provides a new tandem mass spectrometer and methods of using the same for analyzing charged particles. The differentially pumped dual linear quadrupole ion trap mass spectrometer of the present disclose includes a combination of two linear quadrupole (LQIT) mass spectrometers with differentially pumped vacuum chambers.

  9. 21 CFR 862.2860 - Mass spectrometer for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mass spectrometer for clinical use. 862.2860 Section 862.2860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Instruments § 862.2860 Mass spectrometer for clinical use. (a) Identification. A mass spectrometer for...

  10. A magnetic-lens - mini-orange coincidence spectrometer

    International Nuclear Information System (INIS)

    Bargholtz, C.; Holmberg, L.; Ruus, N.; Tegner, P.E.; Weiss, G.

    1997-04-01

    A coincidence spectrometer consisting of a Gerholm type magnetic lens and a permanent magnet mini-orange spectrometer is described. Electron-electron or electron-positron coincidences may be registered in various angular settings. The spectrometer has been developed mainly to search for anomalous contributions to Bhabha scattering or positrons and is at present used for such studies. 6 refs

  11. Measured properties of an out-of-plane spectrometer

    International Nuclear Information System (INIS)

    Mandeville, J.B.; Cardman, L.S.; Dolfini, S.M.; Kim, W.; Laszewski, R.M.; Papanicolas, C.N.; Williamson, S.E.; Alarcon, R.; Goergen, J.; Martinez, D.; Dow, K.; Farkhondeh, M.M.; Tieger, D.; Zumbro, J.; Epstein, M.; Magaziotis, D.; Bernstein, A.; Bertozzi, W.; Bhushan, V.; Gilad, S.; Holtrop, M.; Jordan, D.; McIlvain, T.; Weinstein, L.; Beck, R.; Boeglin, W.; Offermann, E.A.J.M.

    1994-01-01

    We report the results of measurements of the properties of a prototype out-of-plane magnetic spectrometer (OOPS). This spectrometer is one of four identical modules which, together with a support structure, comprise the OOPS cluster. The performance of the spectrometer was found to closely match its design characteristics. (orig.)

  12. Revised ultraviolet absorption cross sections of H2CO for the HITRAN database

    International Nuclear Information System (INIS)

    Chance, K.; Orphal, J.

    2011-01-01

    A revised set of temperature-dependent absorption cross sections for ultraviolet (UV) measurements of formaldehyde (H 2 CO) has been derived from two existing sets of laboratory cross sections, one using a Fourier transform spectrometer (FTS), and one using a grating instrument. This is conducted to satisfy the recommendation of the HITRAN Advisory Committee to provide a dataset with the spectral resolution and wavelength calibration of Fourier transform spectrometer measurements with the better intensity calibration that the grating measurements obtained. The re-scaled cross sections are now in the HITRAN database, and are recommended for use in atmospheric measurements and modeling, including photolysis calculations.

  13. Nuclear power plant transients: where are we

    International Nuclear Information System (INIS)

    Majumdar, D.

    1984-05-01

    This document is in part a postconference review and summary of the American Nuclear Society sponsored Anticipated and Abnormal Plant Transients in Light Water Reactors Conference held in Jackson, Wyoming, September 26-29, 1983, and in part a reflection upon the issues of plant transients and their impact on the viability of nuclear power. This document discusses state-of-the-art knowledge, deficiencies, and future directions in the plant transients area as seen through this conference. It describes briefly what was reported in this conference, emphasizes areas where it is felt there is confidence in the nuclear industry, and also discusses where the experts did not have a consensus. Areas covered in the document include major issues in operational transients, transient management, transient events experience base, the status of the analytical tools and their capabilities, probabilistic risk assessment applications in operational transients, and human factors impact on plant transients management

  14. Numerical solution of transient viscoelastic flow

    DEFF Research Database (Denmark)

    Hassager, Ole; Rasmussen, Henrik K.; Szabo, Peter

    1996-01-01

    A number of applications of the Lagrangina kinematic specification in the simulation of transient viscoelastic flows are shown.......A number of applications of the Lagrangina kinematic specification in the simulation of transient viscoelastic flows are shown....

  15. Frequency-domain multisource optical spectrometer and oximeter

    Science.gov (United States)

    Fantini, Sergio; Franceschini, Maria-Angela; Maier, John S.; Walker, Scott A.; Gratton, Enrico

    1995-01-01

    We have designed and constructed a near-infrared spectrometer for the non-invasive optical study of biological tissue. This instrument works in the frequency-domain and employs multiple source-detector distances to recover the absorption coefficient ((mu) (alpha )) and the reduced scattering coefficient ((mu) s') of tissue. The light sources are eight light emitting diodes (LEDs) whose intensities are modulated at a frequency of 120 MHz. Four LEDs emit light at a peak wavelength of 715 nm ((lambda) 1), while the other four LEDs emit at a peak wavelength of 850 nm ((lambda) 2). From the frequency-domain raw data of phase, dc intensity, and ac amplitude obtained from each one of the eight light sources, which are located at different distances from the detector fiber, we calculate (mu) (alpha ) and (mu) s' at the two wavelengths (lambda) 1 and (lambda) 2. The concentrations of oxy- and deoxy-hemoglobin, and hence hemoglobin saturation, are then derived from the known extinction coefficients of oxy- and deoxy-hemoglobin at (lambda) 1 and (lambda) 2. The statistical error in the measurement of the optical coefficients due to instrument noise is about 1 - 2%. The accuracy in the determination of the absolute value of the optical coefficients is within 10 - 20%. Preliminary results obtained in vivo on the forearm of a volunteer during an ischemia measurement protocol are presented.

  16. Fast thermal transients on valve

    International Nuclear Information System (INIS)

    Ferjancic, M.; Stok, B.; Halilovic, M.; Koc, P.; Mole, N.; Otrin, Z.; Kotar, A.

    2007-01-01

    One of the regulatory body methods to supervise nuclear safety of a nuclear power plant is a review of plant modifications and evaluation of their impact on plant operating experience. The Slovenian Nuclear Safety Administration (SNSA) licensed in April 2003 the use of leak-before-break (LBB) methodology in the Krsko NPP for the primary loop including surge line and connecting pipelines with minimal diameter of 6 inch. The SNSA decision based also on fracture mechanics analyses that include direct pipe failure mechanisms such as water hammer, creep damage, erosion and corrosion, fatigue and environmental conditions over the entire life of the plant. The evaluation of the operating transients pointed out, that presumed loadings, used for the LBB analysis, did not incorporate all the fast thermal transients data. For that purpose the SNSA requested Faculty of Mechanical Engineering (FS) in Ljubljana to perform additional analyses. The results of the analysis shall confirm the validity of the LBB analysis. (author)

  17. Towards traceable transient pressure metrology

    Science.gov (United States)

    Hanson, Edward; Olson, Douglas A.; Liu, Haijun; Ahmed, Zeeshan; Douglass, Kevin O.

    2018-04-01

    We describe our progress in developing the infrastructure for traceable transient measurements of pressure. Towards that end, we have built and characterized a dual diaphragm shock tube that allows us to achieve shock amplitude reproducibility of approximately 2.3% for shocks with Mach speeds ranging from 1.26–1.5. In this proof-of-concept study we use our shock tube to characterize the dynamic response of photonic sensors embedded in polydimethylsiloxane (PDMS), a material of choice for soft tissue phantoms. Our results indicate that the PDMS-embedded photonic sensors response to shock evolves over a tens to hundreds of microseconds time scale making it a useful system for studying transient pressures in soft tissue.

  18. Nonlinear Diffusion and Transient Osmosis

    International Nuclear Information System (INIS)

    Igarashi, Akira; Rondoni, Lamberto; Botrugno, Antonio; Pizzi, Marco

    2011-01-01

    We investigate both analytically and numerically the concentration dynamics of a solution in two containers connected by a narrow and short channel, in which diffusion obeys a porous medium equation. We also consider the variation of the pressure in the containers due to the flow of matter in the channel. In particular, we identify a phenomenon, which depends on the transport of matter across nano-porous membranes, which we call ''transient osmosis . We find that nonlinear diffusion of the porous medium equation type allows numerous different osmotic-like phenomena, which are not present in the case of ordinary Fickian diffusion. Experimental results suggest one possible candidate for transiently osmotic processes. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  19. Absorption heat pumps

    Science.gov (United States)

    Huhtinen, M.; Heikkilae, M.; Andersson, R.

    1987-03-01

    The aim of the study was to analyze the technical and economic feasibility of absorption heat pumps in Finland. The work was done as a case study: the technical and economic analyses have been carried out for six different cases, where in each the suitable size and type of the heat pump plant and the auxiliary components and connections were specified. The study also detailed the costs concerning the procurement, installation and test runs of the machinery, as well as the savings in energy costs incurred by the introduction of the plant. Conclusions were drawn of the economic viability of the applications studied. The following cases were analyzed: heat recovery from flue gases and productin of district heat in plants using peat, natural gas, and municipal wastes as a fuel. Heat recovery in the pulp and paper industry for the upgrading of pressure of secondary steam and for the heating of white liquor and combustion and drying the air. Heat recovery in a peat-fulled heat and power plant from flue gases that have been used for the drying of peat. According to the study, the absorption heat pump suits best to the production of district heat, when the heat source is the primary energy is steam produced by the boiler. Included in the flue as condensing is the purification of flue gases. Accordingly, benefit is gained on two levels in thick applications. In heat and power plants the use of absorption heat pumps is less economical, due to the fact that the steam used by the pump reduces the production of electricity, which is rated clearly higher than heat.

  20. V-FASTR: THE VLBA FAST RADIO TRANSIENTS EXPERIMENT

    International Nuclear Information System (INIS)

    Wayth, Randall B.; Tingay, Steven J.; Brisken, Walter F.; Deller, Adam T.; Majid, Walid A.; Thompson, David R.; Wagstaff, Kiri L.

    2011-01-01

    Recent discoveries of dispersed, non-periodic impulsive radio signals with single-dish radio telescopes have sparked significant interest in exploring the relatively uncharted space of fast transient radio signals. Here we describe V-FASTR, an experiment to perform a blind search for fast transient radio signals using the Very Long Baseline Array (VLBA). The experiment runs entirely in a commensal mode, alongside normal VLBA observations and operations. It is made possible by the features and flexibility of the DiFX software correlator that is used to process VLBA data. Using the VLBA for this type of experiment offers significant advantages over single-dish experiments, including a larger field of view, the ability to easily distinguish local radio-frequency interference from real signals, and the possibility to localize detected events on the sky to milliarcsecond accuracy. We describe our software pipeline, which accepts short integration (∼ ms) spectrometer data from each antenna in real time during correlation and performs an incoherent dedispersion separately for each antenna, over a range of trial dispersion measures. The dedispersed data are processed by a sophisticated detector and candidate events are recorded. At the end of the correlation, small snippets of the raw data at the time of the events are stored for further analysis. We present the results of our event detection pipeline from some test observations of the pulsars B0329+54 and B0531+21 (the Crab pulsar).

  1. The SeaQuest Spectrometer at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Aidala, C.A.; et al.

    2017-06-29

    The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

  2. Portable gas chromatograph-mass spectrometer

    Science.gov (United States)

    Andresen, B.D.; Eckels, J.D.; Kimmons, J.F.; Myers, D.W.

    1996-06-11

    A gas chromatograph-mass spectrometer (GC-MS) is described for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units. 4 figs.

  3. Neutron spectrometer for improved SNM search.

    Energy Technology Data Exchange (ETDEWEB)

    Vance, Andrew L.; Aigeldinger, Georg

    2007-03-01

    With the exception of large laboratory devices with very low sensitivities, a neutron spectrometer have not been built for fission neutrons such as those emitted by special nuclear materials (SNM). The goal of this work was to use a technique known as Capture Gated Neutron Spectrometry to develop a solid-state device with this functionality. This required modifications to trans-stilbene, a known solid-state scintillator. To provide a neutron capture signal we added lithium to this material. This unique triggering signal allowed identification of neutrons that lose all of their energy in the detector, eliminating uncertainties that arise due to partial energy depositions. We successfully implemented a capture gated neutron spectrometer and were able to distinguish an SNM like fission spectrum from a spectrum stemming from a benign neutron source.

  4. PAC Spectrometer for Condensed Matter Investigation

    CERN Document Server

    Brudanin, V B; Kochetov, O I; Korolev, N A; Milanov, M; Ostrovsky, I V; Pavlov, V N; Salamatin, A V; Timkin, V V; Velichkov, A I; Fomicheva, L N; Tsvyaschenko, A V; Akselrod, Z Z

    2005-01-01

    A four-detector spectrometer of perturbed angular $\\gamma \\gamma $ correlations is developed for investigation of hyperfine interactions in condensed matter. It allows measurements with practically any types of detectors. A unique circuit design involving a specially developed Master PAC unit combined with a computer allows a substantially higher efficiency, reduced setup time and simpler operation in comparison with traditional PAC spectrometers. A cryostat and a high-temperature oven allow measurements in the temperature range from 120 to 1300 K. An encased electromagnet makes it possible to generate a magnetic field up to 2 T on a sample. The measurement system includes a press with a specially designed high-pressure chamber allowing on-line PAC measurements in samples under pressure up to 60 GPa.

  5. MEMS tunable grating micro-spectrometer

    Science.gov (United States)

    Tormen, Maurizio; Lockhart, R.; Niedermann, P.; Overstolz, T.; Hoogerwerf, A.; Mayor, J.-M.; Pierer, J.; Bosshard, C.; Ischer, R.; Voirin, G.; Stanley, R. P.

    2017-11-01

    The interest in MEMS based Micro-Spectrometers is increasing due to their potential in terms of flexibility as well as cost, low mass, small volume and power savings. This interest, especially in the Near-Infrared and Mid- Infrared, ranges from planetary exploration missions to astronomy, e.g. the search for extra solar planets, as well as to many other terrestrial fields of application such as, industrial quality and surface control, chemical analysis of soil and water, detection of chemical pollutants, exhausted gas analysis, food quality control, process control in pharmaceuticals, to name a few. A compact MEMS-based Spectrometer for Near- Infrared and Mid-InfraRed operation have been conceived, designed and demonstrated. The design based on tunable MEMS blazed grating, developed in the past at CSEM [1], achieves state of the art results in terms of spectral resolution, operational wavelength range, light throughput, overall dimensions, and power consumption.

  6. Time-of-flight mass spectrometer

    International Nuclear Information System (INIS)

    Managadze, G.G.

    1991-01-01

    A time-of-flight mass spectrometer comprises an ion source consisting of a grid assembly, a drift space with a focusing system, a reflector and a detector. The grid assembly has the shape of a ring with the internal diameter equal to that of the detector, whereas the focusing system consists of two cylinders coaxially mounted in the drift space whose diameters are equal, respectively, to the internal and the external diameter of the grid assembly of the ion source. The time-of-flight mass spectrometer is intended mainly for studying the mass composition of an inert gas, of a low-energy ion flux as well as of a plasma in a vacuum. (author)

  7. Interface for liquid chromatograph-mass spectrometer

    Science.gov (United States)

    Andresen, Brian D.; Fought, Eric R.

    1989-01-01

    A moving belt interface for real-time, high-performance liquid chromatograph (HPLC)/mass spectrometer (MS) analysis which strips away the HPLC solvent as it emerges from the end of the HPLC column and leaves a residue suitable for mass-spectral analysis. The interface includes a portable, stand-alone apparatus having a plural stage vacuum station, a continuous ribbon or belt, a drive train magnetically coupled to an external drive motor, a calibrated HPLC delivery system, a heated probe tip and means located adjacent the probe tip for direct ionization of the residue on the belt. The interface is also capable of being readily adapted to fit any mass spectrometer.

  8. Feasibility studies for the Forward Spectrometer

    International Nuclear Information System (INIS)

    Biernat, Jacek

    2015-01-01

    The Forward Spectrometer designed for the P-barANDA detector will consist of many different detector systems allowing for precise track reconstruction and particle identification. Feasibility studies for Forward Spectrometer done by means of specific reactions will be presented. In the first part of the paper, results of simulations focussing on rate estimates of the tracking stations based on straw tubes will be presented. Next, the importance of the Forward Tracker will be demonstrated through the reconstruction of the ψ(4040) → DD-bar decay. Finally, results from the analysis of the experimental data collected with a straw tube prototype designed and constructed at the Research Center in Juelich will be discussed. (paper)

  9. Inelastic rotor spectrometer at the Harwell Linac

    International Nuclear Information System (INIS)

    Boland, B.C.

    1983-01-01

    The spectrometer is designed to measure energy transfer from 50 MeV to 400 MeV covering a range of Q values from 1 to 15 A - 1 . Particular emphasis has been placed on the low Q counter banks where measurements at low Q reduce multiphonon contributions in vibrational spectra, diffusional broadening in liquids and allow measurements to be made on magnetic excitations. All indications are that the energy resolution is as predicted and is certainly twice as good as that of any other spectrometer presently available to the UK users at these energy transfers. Backgrounds on the high angle banks 24 0 to 94 0 are excellent but at the low angles are too high at present for anything but hydrogenous samples. Tests have shown that much of this background comes from the main beam in the area of the collimation between the chopper and the sample, and steps are being taken to improve this area

  10. Superheated drop as a neutron spectrometer

    Science.gov (United States)

    Das, Mala; Chatterjee, B. K.; Roy, B.; Roy, S. C.

    2000-09-01

    Superheated drops are known to vaporise when exposed to energetic nuclear radiation since the discovery of bubble chamber. The application of superheated drops in neutron research especially in neutron dosimetry is a subject of intense research for quite sometime. As the degree of superheat increases in a given liquid, less and less energetic neutrons are required to cause nucleation. This property of superheated liquid makes it possible to use it as a neutron spectrometer. Neutron detection efficiency of superheated drops made of R12 exposed to Am-Be neutron source has been measured over a wide range of temperature -17-60°C and the results have been utilised to construct the energy spectrum of the neutron source. This paper demonstrates that a suitable neutron spectrometer may be constructed by using a single liquid and varying the temperature of the liquid suitably at a closer grid.

  11. Superheated drop as a neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Das, Mala; Chatterjee, B.K.; Roy, B. E-mail: biva@bosemain.boseinst.ernet.in; Roy, S.C

    2000-09-21

    Superheated drops are known to vaporise when exposed to energetic nuclear radiation since the discovery of bubble chamber. The application of superheated drops in neutron research especially in neutron dosimetry is a subject of intense research for quite sometime. As the degree of superheat increases in a given liquid, less and less energetic neutrons are required to cause nucleation. This property of superheated liquid makes it possible to use it as a neutron spectrometer. Neutron detection efficiency of superheated drops made of R12 exposed to Am-Be neutron source has been measured over a wide range of temperature -17-60 deg. C and the results have been utilised to construct the energy spectrum of the neutron source. This paper demonstrates that a suitable neutron spectrometer may be constructed by using a single liquid and varying the temperature of the liquid suitably at a closer grid.

  12. Imaging spectrometer wide field catadioptric design

    Science.gov (United States)

    Chrisp,; Michael, P [Danville, CA

    2008-08-19

    A wide field catadioptric imaging spectrometer with an immersive diffraction grating that compensates optical distortions. The catadioptric design has zero Petzval field curvature. The imaging spectrometer comprises an entrance slit for transmitting light, a system with a catadioptric lens and a dioptric lens for receiving the light and directing the light, an immersion grating, and a detector array. The entrance slit, the system for receiving the light, the immersion grating, and the detector array are positioned wherein the entrance slit transmits light to the system for receiving the light and the system for receiving the light directs the light to the immersion grating and the immersion grating receives the light and directs the light through the system for receiving the light to the detector array.

  13. Status of the LEP2 Spectrometer Project

    CERN Document Server

    Dehning, Bernd; Bovet, Claude; Coosemans, Williame; Cornuet, D; Hidalgo, A; Hilleret, Noël; Hublin, M; Kalbreier, Willi; Leclère, P; Matheson, J; Mugnai, G; Muttoni, Y; Myers, S; Occelli, B; Palacios, J; Perret, R; Placidi, Massimo; Prochnow, J; Rühl, I; Sassowsky, M; Schmickler, Hermann; Valbuena, R; Wells, P S; Wenninger, J; Wilkinson, G R; Hildreth, M D; Roncarolo, F; Torrence, E

    2000-01-01

    The LEP spectrometer has been conceived to provide a determination of the beam energy with a relative accuracy of 10-4 in the LEP2 physics region where insufficient polarisation levels prevent the application of the resonant depolarisation method. The setup consists of a steel bending magnet flanked by a triplet of Beam Position Monitors (BPM) at each side providing a measurement of changes in the bending angle when the beams are accelerated to physics energies. The goal for a 100 ppm relative precision on the beam energy involves a ± 1 micron BPM resolution and the calibration of the dipole bending strength to a 30 ppm accuracy. This paper reports on the results of the commissioning of the Spectrometer during the 1999 LEP Run and on the experience acquired on the behaviour of the several sub-systems with circulating beams.

  14. Cryogenic system for a superconducting spectrometer

    International Nuclear Information System (INIS)

    Porter, J.

    1983-03-01

    The Heavy Ion Spectrometer System (HISS) relies upon superconducting coils of cryostable, pool boiling design to provide a maximum particle bending field of 3 tesla. This paper describes the cryogenic facility including helium refrigeration, gas management, liquid nitrogen system, and the overall control strategy. The system normally operates with a 4 K heat load of 150 watts; the LN 2 circuits absorb an additional 4000 watts. 80K intercept control is by an LSI 11 computer. Total available refrigeration at 4K is 400 watts using reciprocating expanders at the 20K and 4K level. The minicomputer has the capability of optimizing overall utility input cost by varying operating points. A hybrid of pneumatic, analog, and digital control is successful in providing full time unattended operation. The 7m diameter magnet/cryostat assembly is rotatable through 180 degrees to provide a variety of spectrometer orientations

  15. Associated Particle Tagging (APT) in Magnetic Spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, David V.; Baciak, James E.; Stave, Sean C.; Chichester, David; Dale, Daniel; Kim, Yujong; Harmon, Frank

    2012-10-16

    Summary In Brief The Associated Particle Tagging (APT) project, a collaboration of Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL) and the Idaho State University (ISU)/Idaho Accelerator Center (IAC), has completed an exploratory study to assess the role of magnetic spectrometers as the linchpin technology in next-generation tagged-neutron and tagged-photon active interrogation (AI). The computational study considered two principle concepts: (1) the application of a solenoidal alpha-particle spectrometer to a next-generation, large-emittance neutron generator for use in the associated particle imaging technique, and (2) the application of tagged photon beams to the detection of fissile material via active interrogation. In both cases, a magnetic spectrometer momentum-analyzes charged particles (in the neutron case, alpha particles accompanying neutron generation in the D-T reaction; in the tagged photon case, post-bremsstrahlung electrons) to define kinematic properties of the relevant neutral interrogation probe particle (i.e. neutron or photon). The main conclusions of the study can be briefly summarized as follows: Neutron generator: • For the solenoidal spectrometer concept, magnetic field strengths of order 1 Tesla or greater are required to keep the transverse size of the spectrometer smaller than 1 meter. The notional magnetic spectrometer design evaluated in this feasibility study uses a 5-T magnetic field and a borehole radius of 18 cm. • The design shows a potential for 4.5 Sr tagged neutron solid angle, a factor of 4.5 larger than achievable with current API neutron-generator designs. • The potential angular resolution for such a tagged neutron beam can be less than 0.5o for modest Si-detector position resolution (3 mm). Further improvement in angular resolution can be made by using Si-detectors with better position resolution. • The report documents several features of a notional generator design incorporating the

  16. Transient pseudohypoparathyroidism and neonatal seizure.

    Science.gov (United States)

    Manzar, S

    2001-04-01

    The case of a neonate is presented who had late onset seizure associated with hypocalcemia, hyperphosphatemia, and raised parathyroid hormone. The infant did not have any stigmata of pseudohypoparathyroidism. The hypocalcemia was initially resistant to calcium therapy, but responded to vitamin D analog therapy. The diagnosis of 'transient neonatal pseudohypoparathyroidism' was entertained, as the infant remained stable and seizure-free with normal serum biochemistry during 8 months of follow-up.

  17. Transient cognitive changes after craniotomy.

    Science.gov (United States)

    Hannegan, L

    1989-06-01

    Little has been written on the subject of cognitive and behavioral changes that may follow craniotomy. Neuroscience nurses who care for craniotomy patients often see transient alterations in behavior, intellect and personality similar to those occurring after minor head injury or subarachnoid hemorrhage. These changes may lead to depression and alter family dynamics. Interventional strategies, including cognitive screening, family counseling and thorough discharge planning are essential for helping patients and family members anticipate potential deficits and cope with life after craniotomy.

  18. Rapidly variable relatvistic absorption

    Science.gov (United States)

    Parker, M.; Pinto, C.; Fabian, A.; Lohfink, A.; Buisson, D.; Alston, W.; Jiang, J.

    2017-10-01

    I will present results from the 1.5Ms XMM-Newton observing campaign on the most X-ray variable AGN, IRAS 13224-3809. We find a series of nine absorption lines with a velocity of 0.24c from an ultra-fast outflow. For the first time, we are able to see extremely rapid variability of the UFO features, and can link this to the X-ray variability from the inner accretion disk. We find a clear flux dependence of the outflow features, suggesting that the wind is ionized by increasing X-ray emission.

  19. Geospatial Absorption and Regional Effects

    Directory of Open Access Journals (Sweden)

    IOAN MAC

    2009-01-01

    Full Text Available The geospatial absorptions are characterized by a specific complexity both in content and in their phenomenological and spatial manifestation fields. Such processes are differentiated according to their specificity to pre-absorption, absorption or post-absorption. The mechanisms that contribute to absorption are extremely numerous: aggregation, extension, diffusion, substitution, resistivity (resilience, stratification, borrowings, etc. Between these mechanisms frequent relations are established determining an amplification of the process and of its regional effects. The installation of the geographic osmosis phenomenon in a given territory (a place for example leads to a homogenization of the geospatial state and to the installation of the regional homogeneity.

  20. Synchronized high speed scanning infrared spectrometer.

    Science.gov (United States)

    Camm, J C; Taylor, R L; Lynch, R

    1967-05-01

    A spectrometer which scans a wavelength band of 0.6 micro in 30 microsec and is useful from 2-6 micro is described. The instrument can be synchronized with a pulsed source with a minimum triggering delay of 15microsec. The instrument is basically an Ebert spectrometer equipped with an indium antimonide detector at the exit slit, an aluminum scanning mirror placed 5 cm before the exit slit, and a wavelength calibration signal generator. The scanning mirror, which is supported on pivots inside a helical coil, deflects the spectrum through an angle of approximately 90 degrees onto the exit slit. When a capacitor is discharged through the coil, the resulting magnetic field spins the aluminum mirror causing the spectrum to move across the exit slit. The wavelength calibration signal generator produces a series of electrical pulses as the scanning mirror turns, permitting wavelength calibration when the pulses are displayed below the spectrometer signal on a dual beam oscilloscope. Using this instrument on a shock tube, data have bee obtained on the absolute spectral radiation intensity of air, nitrogen, neon, and argon heated by reflected shocks to equilibrium temperatures in the range of 6000 degrees K to 10,000 degrees K. In this temperature region with these gases, an important source of continuum radiation is neutral Bremsstrahlung caused by the inelastic scattering of electrons from neutral atoms and molecules. By employing the scanning ir spectrometer it has been possible to separate the continuum radiation from contributions owing to lines and bands and determine the cross section for the neutral Bremsstrahlung.