WorldWideScience

Sample records for transhepatic inferior vena

  1. Bilhemia: a fatal complication following percutaneous placement of a transhepatic inferior vena cava catheter in a child

    International Nuclear Information System (INIS)

    Sierre, Sergio; Lipsich, Jose; Questa, Horacio

    2007-01-01

    A transhepatic central venous catheter was implanted in a 2-year-old child with a history of multiple venous access procedures and superior and inferior vena cava thrombosis. After 2 weeks, inadvertent dislodgement of the catheter was complicated by a biloma. The biloma was percutaneously drained, but a biliary-venous fistula led to a rapidly progressive and fatal bilhemia. We report this case as an infrequent complication of transhepatic catheterization. (orig.)

  2. Collateral circulations in inferior vena cava obstruction

    International Nuclear Information System (INIS)

    Lee, Jong Beum; Park, Jae Hyung; Han, Man Chung; Park, Soo Soung

    1985-01-01

    Obstruction of the inferior vena cava (IVC) is an uncommon condition, and the collateral pathway varies according to the level, extent, duration and the cause of obstruction. Membranous obstruction of IVC in its hepatic portion might be one of the principle cause among Korean, though not reported till now. Analytical study was performed in 26 cases of IVC obstruction with various cause. 1. The level of the obstruction showed relatively even distribution as follows, upper caval in 11 cases, middle caval in 6 cases and infrarenal in 9 cases. 2. The main cause of upper caval obstruction was membranous obstruction. 3. As a whole, the main collateral pathway was the central route (22 cases: 85%). 4. Characteristic collateral pathway unique to upper caval obstruction was transhepatic venous collateral, developed between the obstructed segment and unobstructed segment of IVC. 5. Scalloping of left cardiac border produced by pericardiophrenic venous collateral was characteristic simple chest x-ray finding in IVC obstruction

  3. Anomalies of the vena cava inferior

    International Nuclear Information System (INIS)

    Koen, F.R.; Bouwer, A.J.; Bornman, M.S.; Du Plessis, D.J.

    1986-01-01

    Two cases of anomalous inferior vena cava are presented, with the emphasis on embryology. The firts patient was investigated by venography for a clinically proven varicocele as a probable cause of infertility. A double inferior vena cava was found during venography, and was confirmed by computed tomography (CT). In the second case a left-sided inferior vena cava was an incidental finding when a CT scan was done as a diagnostic procedure in a case of Hodgkin's disease. A short summary of the embryology and the significance of the variants is presented

  4. Transhepatic approach for extracardiac inferior cavopulmonary connection stent fenestration.

    LENUS (Irish Health Repository)

    Kenny, Damien

    2012-02-01

    We report on a 3-year-old male who underwent transcatheter stent fenestration of the inferior portion of an extracardiac total cavopulmonary connection in the setting of hypoplastic left heart syndrome. Transhepatic approach, following an unsuccessful attempt from the femoral vein facilitated delivery of a diabolo-shaped stent.

  5. Total laparoscopic retrieval of inferior vena cava filter.

    Science.gov (United States)

    Benrashid, Ehsan; Adkar, Shaunak Sanjay; Bennett, Kyla Megan; Zani, Sabino; Cox, Mitchell Wayne

    2015-01-01

    While there is some local variability in the use of inferior vena cava filters and there has been some evolution in the indications for filter placement over time, inferior vena cava filters remain a standard option for pulmonary embolism prophylaxis. Indications are clear in certain subpopulations of patients, particularly those with deep venous thrombosis and absolute contraindications to anticoagulation. There are, however, a variety of reported inferior vena cava filter complications in the short and long term, making retrieval of the filter desirable in most cases. Here, we present the case of a morbidly obese patient complaining of chronic abdominal pain after inferior vena cava filter placement and malposition of the filter with extensive protrusion outside the inferior vena cava. She underwent successful laparoscopic retrieval of her malpositioned inferior vena cava filters after failure of a conventional endovascular approach.

  6. Total laparoscopic retrieval of inferior vena cava filter

    Directory of Open Access Journals (Sweden)

    Ehsan Benrashid

    2015-08-01

    Full Text Available While there is some local variability in the use of inferior vena cava filters and there has been some evolution in the indications for filter placement over time, inferior vena cava filters remain a standard option for pulmonary embolism prophylaxis. Indications are clear in certain subpopulations of patients, particularly those with deep venous thrombosis and absolute contraindications to anticoagulation. There are, however, a variety of reported inferior vena cava filter complications in the short and long term, making retrieval of the filter desirable in most cases. Here, we present the case of a morbidly obese patient complaining of chronic abdominal pain after inferior vena cava filter placement and malposition of the filter with extensive protrusion outside the inferior vena cava. She underwent successful laparoscopic retrieval of her malpositioned inferior vena cava filters after failure of a conventional endovascular approach.

  7. Retroperitoneal arteriovenous malformation extending through the inferior vena cava into the heart and causing inferior vena cava dissection

    International Nuclear Information System (INIS)

    Sung, Yon Mi; Choe, Yeon Hyeon; Park, Seung Woo; Park, Pyo Won; Sung, Chang Ohk

    2005-01-01

    We present a case of retroperitoneal arteriovenous malformation extending through the inferior vena cava into the heart, which was associated with dissection of the inferior vena cava in a 32-year-old female. Computed tomography and magnetic resonance imaging showed a double-lumen inferior vena cava and a rod-like solid component attached to a sac-like lesion in the right heart chambers. Digital subtraction angiography showed an arteriovenous malformation draining to the inner lumen of the inferior vena cava. (orig.)

  8. Endovascular management of inferior vena cava filter thrombotic occlusion.

    Science.gov (United States)

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  9. The clinical application of inferior vena caval CO2-DSA

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; Zhu Guangyu; Li Guozhao; Fang Wen; He Shicheng; Deng Tang

    2007-01-01

    Objective: To explore the feasibility and safety of inferior vena caval CO 2 -DSA and evaluate the results of inferior vena cavography using CO 2 -DSA or iodinated contrast media. Methods: 25 patients diagnosed as deep venous thrombosis of lower limb were prepared to conceive the implantation of inferior vena caval filter. The inferior vena cava and right renal vein CO 2 -DSA and iodinated contrast media DSA were carried out through jugular or femoral vein approach in all patients. Results: The inferior vena caval angiography with CO 2 -DSA or iodinated contrast media were carried out successfully in all patients. The quality of the inferior vena caval angiogram showed: with CO 2 as contrast media, 14 cases obtained excellent images and 11 cases had good images; with iodinated contrast media the images of 18 cases were excellent and 7 cases were good. No thrombus and variation of inferior vena cava were found by the two kinds of angiography. The diameter of inferior vena cava showed: (20.01 ± 0.83) mm with CO 2 contrast media and (20.15 ± 0.92) mm with iodinated contrast media, (P=0.006); having statistical significance between them. The safety of angiography with CO 2 presented only 1 case with transient slight decrease of O 2 saturation. No abnormal changes were found in blood pressure, heart rate and so on. Conclusions: Inferior vena caval CO 2 -DSA is feasible and safe, with statistical significance in the measurement of inferior vena caval diameter comparing with iodinated contrast material but with no influence on the implantation of filter. (authors)

  10. Inferior vena cava obstruction and shock

    Directory of Open Access Journals (Sweden)

    Megri Mohammed

    2018-01-01

    Full Text Available Shock is one of the most challenging life-threatening conditions with high mortality and morbidity; the outcomes are highly dependent on the early detection and management of the condition. Septic shock is the most common type of shock in the Intensive Care Unit. While not as common as other subsets of shock, obstructive shock is a significant subtype due to well defined mechanical and pathological causes, including tension pneumothorax, massive pulmonary embolism, and cardiac tamponade. We are presenting a patient with obstructive shock due to inferior vena cava obstruction secondary to extensive deep venous thrombosis. Chance of survival from obstructive shock in our patient was small; however, there was complete and immediate recovery after treatment of the obstruction on recognizing the affected vessels. This case alerts the practicing intensivist and the emergency medicine physician to consider occlusion of the great vessels other than the pulmonary artery or aorta as causes of obstructive shock.

  11. 'Pseudothrombus' of the inferior vena cava

    International Nuclear Information System (INIS)

    Takebayashi, Shigeo; Odagiri, Kunio; Matsui, Kengo; Hayano, Ikuo.

    1983-01-01

    Normal Inferior Vena Cava (IVC) of 15 cases were studies on CT with bolus injection in the foot vein.FWell dilated IVC were obtained on scan both at full-inspiration and full-expiration. As the normal findings of IVC, different opacification patterns which may be designate ''homogenous'', ''layered'' and ''pseudothrombus'' were obtained. The ''homogenous'' opacification was noted both at full-inspiration and full-expiration. In homogenous patterns as noted as ''layered'' and ''pseudothrombus'' were suspected to occur in the case of insufficient mixing of contrast agent with blood and/or insufficient amount of contrast agent. And both these patterns were observed in dilated IVC. The ''layered'' opacified IVC was shown on scan at full-inspiration at which respiratory phase the blood flow in IVC may decrease.FThe ''pseudothrombus'' pattern was generally noted at full-expiration at which the blood flow may increase.FAlthough bolus injection of contrast agent into foot vein is useful for evaluation of IVC, one shound be aware of normal opacification of IVC including ''pseudothrombus'' pattern. (author)

  12. Symplastic Leiomyoma in the Suprarenal Inferior Vena Cava

    International Nuclear Information System (INIS)

    Kahveci, Volkan; Ogur, Torel; Cipe, Gokhan; Ozdemir, Sevim; Hazinedaroglu, Selcuk

    2012-01-01

    Leiomyomas are benign tumors of the soft tissue and may develop in any location where smooth muscle is present. Leiomyoma in the inferior vena cava is a rarely seen pathology, and symplastic leiomyoma is also a rare histological variant of leiomyoma. In this case, we present a rare histological variant of symplastic leiomyoma in the inferior vena cava (IVC). This is the first radiologically reported case of a symplastic leiomyoma of the IVC

  13. Symptomatic duodenal perforation by inferior vena cava filter.

    Science.gov (United States)

    Baptista Sincos, Anna Pw; Sincos, Igor R; Labropoulos, Nicos; Donegá, Bruno C; Klepacz, Andrea; Aun, Ricardo

    2017-01-01

    Objectives Duodenal perforation by an inferior vena cava filter is rare and life threatening. Our objective is to find out number of occurrences and compare diagnosis and treatments. Method The reference list of Malgor's review in 2012 was considered as well as all new articles with eligible features. Search was conducted on specific databases: MEDLINE, Web of Sciences, and Literatura Latino-Americana e do Caribe em Ciências da Saúde. Results Most of the patients presented with upper abdominal pain and the use of radiologic studies was crucial for diagnosis. The most common treatment was laparotomy with filter or strut removal plus duodenum repair. However, clinical conditions of patients must be considered and the endovascular technique with endograft deployment into inferior vena cava may be an alternative. Conclusion Duodenal perforation by an inferior vena cava filter is uncommon and in high-risk surgical patients endovascular repair must be considered.

  14. Renal Angiomyolipoma Associated with Inferior Vena Cava Thrombus

    Directory of Open Access Journals (Sweden)

    Xavier Durand

    2009-01-01

    Full Text Available A 57-year-old woman was found to have an inferior vena cava involvement of a known sinusal angiomyolipoma incompletely resected three years beforehand. Intravascular extension into the IVC of angiomyolipoma has rarely been reported. We present a new case and reconsider the literature about this uncommon complication of a benign renal tumor.

  15. Asymptomatic Lumbar Vertebral Erosion from Inferior Vena Cava Filter Perforation

    International Nuclear Information System (INIS)

    Fang, Wayne; Hieb, Robert A.; Olson, Eric; Carrera, Guillermo F.

    2007-01-01

    In 2002, a 24-year-old female trauma patient underwent prophylactic inferior vena cava filter placement. Recurrent bouts of renal stones prompted serial CT imaging in 2004. In this brief report, we describe erosion and ossification of the L3 vertebral body by a Greenfield filter strut

  16. Injuries of the retrohepatic inferior vena cava and the liver

    Directory of Open Access Journals (Sweden)

    Koprivica Radenko

    2008-01-01

    Full Text Available Beckground. Injuries of the retrohepatic inferior vena cava, and the liver have mortality rate up to 71-78%. We presented a patient with combined injury of the retrohepatic inferior vena cava, liver, craniocerebral and thoracic traumas, inflicted in a traffic accident. Case report. Man, 20 years old has been injured in a traffic accident. At admission, 20 minutes after the injury, the patient was comatose and hypotensive. Bloody content was obtained by abdominal tracer. The patient underwent emergent laparotomy, utilizing trifurcated incision and cell saver device. Abdominal exploration revealed two liters of free blood and massive retroperitoneal hematoma. Manual compression of the liver was done, as well as perihepatic packing, complete hepatic vascular exclusion and mobilization of the right liver lobe. Due to impressive chemodynamic instability supraceliac aortic clamping was performed. Upon exposure of the retrohepatic inferior vena cava and right liver lobe, multiple lacerations of retrohepatic inferior vena cava and right hepatic vein, and right hepatic vein avulsion were found. We also identified an injury of VII and VIII segments of the liver (grade V according to the Moore's classification. Nonexpansive hepatoduodenal ligament hematoma and the injury of II and III segments of the liver group II/III according to Moore were found. Venorrhaphy of the inferior vena cava was done in the area of circumference of the right hepatic vein, a portion of which served as autologous vein patch. Continuous prolene 3/0 venorrhaphy of the distal caval laceration was done. Total caval and aorta clamping time of the inferior vena cava was 41 minutes. Atypical resection, debridment, of hepatic segments was done by using a harmonic scalpel. Hepatoduodenal ligament was declamped after 65 minutes. Fibrin glue was applied on the resectioned area of liver. The patient received 3.2 l of autologuos blood transfusion with 5 units of packed red blood cells, 6

  17. Prosthetic replacement of the infrahepatic inferior vena cava for leiomyosarcoma.

    Science.gov (United States)

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca

    2006-09-01

    Resection of the infrahepatic inferior vena cava associated with prosthetic graft replacement for caval leiomyosarcoma is an acceptable procedure to obtain prolonged and good-quality survival. A consecutive sample clinical study with a mean follow-up of 40 months. The surgical department of an academic tertiary center and an affiliated secondary care center. Eleven patients, with a mean age of 51 years, who have primary leiomyosarcoma of the infrahepatic inferior vena cava. All of the patients underwent radical resection of the tumor en bloc with the affected segment of the vena cava. Reconstruction consisted of 10 cavocaval polytetrafluoroethylene grafts and 1 cavobiliac graft. An associated right nephrectomy was performed in 2 cases. The left renal vein was reimplanted in the graft in 3 cases. Cumulative disease-specific survival, disease-free survival, and graft patency rates expressed by standard life-table analysis. No patients died in the postoperative period. The cumulative (SE) disease-specific survival rate was 53% (21%) at 5 years. The cumulative (SE) disease-free survival rate was 44% (19%) at 5 years. The cumulative (SE) graft patency rate was 67% (22%) at 5 years. Radical resection followed by prosthetic graft reconstruction is a valuable method for treating primary leiomyosarcoma of the infrahepatic inferior vena cava.

  18. Liver trauma and transection of the inferior vena cava

    International Nuclear Information System (INIS)

    Radin, D.R.

    1992-01-01

    CT of a child with severe liver trauma due to a seat belt injury demonstrated avulsion of a portion of the lateral segment of the left lobe of the liver. The location of nondependent extravasated contrast material aided in identification of the visceral fracture site (the sentinel contrast sign). Associated transection of the inferior vena cava was evidenced by hypoatenuating zones adjacent to all the major hepatic veins and vena cava (hepatic perivenous tracking). Recognition of these two signs is important so that the radiologist can help the surgeon select the optimal operative approach. (orig.)

  19. Superior and inferior vena cavae: Embryology, variants, and pathology

    International Nuclear Information System (INIS)

    Mendelson, D.S.; Mitty, H.; Janus, C.; Gendal, E.; Berson, B.

    1987-01-01

    The superior and inferior venae cavae may be involved in a host of disease processes. Knowledge of the normal anatomy and variants of these structures is valuable in interpreting plain films and the results of angiographic procedures and all cross-sectional modalities. The authors review the embryology of venae cavae and proceed to describe their normal anatomy and variants. An awareness of the variants can prevent mistaking variants for pathologic processes. Finally, the authors describe pathology involving these vessels and demonstrate the radiographic manifestations

  20. Optional inferior vena caval filters: where are we now?

    LENUS (Irish Health Repository)

    Keeling, A N

    2008-08-01

    With the advent of newer optional\\/retrievable inferior vena caval filters, there has been a rise in the number of filters inserted globally. This review article examines the currently available approved optional filter models, outlines the clinical indications for filter insertion and examines the expanding indications. Additionally, the available evidence behind the use of optional filters is reviewed, the issue of anticoagulation is discussed and possible future filter developments are considered.

  1. Spiral CT in aplasia of the pre-renal inferior vena cava as a cause of phlebothrombosis from the femoral veins to the inferior vena cava; Spiral-CT einer Aplasie der praerenalen Vena cava inferior als Ursache einer Phlebothrombose von den Oberschenkelvenen bis in die Vena cava inferior

    Energy Technology Data Exchange (ETDEWEB)

    Schweiger, U. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Schedel, H. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Thiede, U. [Deutsches Herzzentrum Berlin (Germany). Arbeitsgruppe Digitale Bildbearbeitung; Felix, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1994-12-31

    The case report focuses on the computed tomography of the thrombotic okklusion of the inferior vena cava, venae iliacae and femorales communes due to congenital interruption of the prerenal inferior vena cava. The embryology of the abnormality was discussed. (orig.) [Deutsch] Anhand einer Fallstudie wurden die Moeglichkeiten der computertomographischen Diagnostik bei einer durch Teilplasie der `praerenalen` Vena cava inferior hervorgerufenen Thrombose der Vv. femorales superficiales et profundae, der grossen Beckenvenen und der Vena cava inferior erlaeutert. In der Diskussion wurde auf die Embryologie der Missbildung eingegangen. (orig.)

  2. Recidiva en vena cava inferior de carcinoma suprarrenal

    Directory of Open Access Journals (Sweden)

    Javier Orrit

    2005-01-01

    Full Text Available Paciente de 15 meses sometido a resección de masa suprarrenal derecha. Estudio de extensión negativo e histología de tumor adrenocortical. Dos meses después presenta recidiva tumoral en vena cava inferior (VCI a nivel de venas suprahepáticas que se reseca bajo hipotermia profunda y parada circulatoria (19 min (Fig. 1. Se extrae una masa friable de 25 × 20 mm que ocluye la VCI, sin evidencia de resto tumoral, aunque se considera resección incompleta al estar infiltradas las paredes de VCI. La histología confirma carcinoma suprarrenal (Fig. 2. A los 5 meses sigue quimioterapia sin datos de nueva invasión de VCI.

  3. Detection by means of CT of inferior vena cava filters

    International Nuclear Information System (INIS)

    Zurera Tendero, L.J.; Canis Lopez, M.; Oteros Fernandez, R.; Ramos Gomez, M.; Garcia Revillo, J.; Roman Rios, G.

    1995-01-01

    Vena cava filters are an excellent tool for the prevention of pulmonary embolism (PE) in patients with deep vein thrombosis (DVT) of the lower limbs. However, these devices are not entirely free of complications as thrombi can develop inside them, threatening to occlude them completely. The objective of this report is to study the incidence of thrombosis in vena cava filters, as well as their impact on prognosis. We also mention the importance of CT as an imaging technique in the study of this complication. We present 30 patients in whom different filters were implanted and their prospective follow-up by means of CT over a mean follow-up period of 36 months. Chi-square analysis was used to determine whether there was a significant relationship among the complications encountered (p<0,05), and their course over time was studied by means of Kaplan-Meyer curves. Five cases (16%) of complete thrombosis of the filter were observed among patients in whom the Gunther model had been implanted, yielding an index of probability of complete permeability of the inferior vena cava at 13 months of 82%. Thrombi of different degrees (between 5% and 60%) were also observed inside the filter in ten patients (33%) with Gunther, Simon-Nitional and LGM models. Filter thrombosis was not significantly associated with the onset of recurrent PE or of venous disorders involving lower limbs, the relationship between PE and preimplantation presence of inferior vena cava thrombosis was significant (p<0.01). It was also observed that post implantation anti coagulation did not significantly prevent later onset of filter thrombosis. (Author)

  4. Omental flap transposition for inferior vena cava filter penetration

    Directory of Open Access Journals (Sweden)

    Junji Yamaguchi, MD

    2017-03-01

    Full Text Available A 40-year-old woman presented with uterine malignancy, deep vein thrombosis, and nonmassive pulmonary embolism in both lungs. Gunter-tulip filter was inserted, because she had severe genital bleeding, which is one of the contraindications to anticoagulation therapy. Total hysterectomy was conducted and anticoagulation therapy was started afterward. The thrombus worsened perioperatively, and the filter could not be retrieved. Since there was lymph node recurrence, the second time operation was performed. During operation, the struts were found to be penetrating the inferior vena cava. Omental flap was used to cover the struts, and no associated complications occurred after operation.

  5. Symptomatic caval penetration by a Celect inferior vena cava filter

    International Nuclear Information System (INIS)

    Bogue, Conor O.; John, Philip R.; Connolly, Bairbre L.; Rea, David J.; Amaral, Joao G.

    2009-01-01

    We report a case of penetration of the inferior vena cava (IVC) by all four primary struts of a Celect caval filter in a 17-year-old girl with Klippel-Trenaunay syndrome. The girl presented with acute lower abdominal and right leg pain 17 days after filter insertion. An abdominal radiograph demonstrated that the filter had moved caudally and that the primary struts had splayed considerably since insertion. Contrast-enhanced CT confirmed that all four primary struts had penetrated the IVC wall. There was a small amount of retroperitoneal hemorrhage. The surrounding vessels and viscera were intact. The filter was subsequently retrieved without complication. (orig.)

  6. An unusual cause of an inferior vena cava syndrome

    NARCIS (Netherlands)

    Regoort, M.; Reekers, J. A.; Kromhout, J. G.

    1989-01-01

    Two patients are presented with an occlusion of the infrarenal vena cava caused by a vena cava aneurysm. This rare congenital vena caval anomaly may mimic retroperitoneal lymphadenopathy, especially on CT- imaging without contrast enhancement

  7. Blunt injury of the infrarenal inferior vena cava — imaging and ...

    African Journals Online (AJOL)

    Blunt injury of the infrarenal inferior vena cava — imaging and conservative management. Ian C Duncan, Basil J Sher, Leslie M Fingleson. Abstract. Isolated rupture of the infrarenal segment of the inferior vena cava due to blunt trauma is relatively rare. It may be missed clinically and even diagnostic peritoneal lavage may ...

  8. Computed tomographic diagnosis of calcified inferior vena cava thrombus in a child with Wilm's tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kirks, D R; Ponzi, J W; Korobkin, M

    1980-01-01

    A calcified thrombus in the inferior vena cava of infants and children may be imaged by computed tomography. The precise location of the calcification within the inferior vena cava may be confirmed by computed tomographic scanning during injection of intravenous contrast material.

  9. Marker-Negative Pheochromocytoma Associated with Inferior Vena Cava Thrombosis

    Directory of Open Access Journals (Sweden)

    S. Poudyal

    2017-01-01

    Full Text Available Pheochromocytoma associated with inferior vena cava (IVC thrombosis is very rare. A 27-year-old female presented with right flank pain and hypertensive urgency. Contrast-enhanced CT abdomen and gadolinium-contrast MRI abdomen revealed right adrenal mass suspicious of malignancy with invasion and compression to the right IVC wall along with IVC thrombus extending from the level of renal veins to the level of confluence with hepatic veins. Her routine laboratory investigations including 24-hour urine fractionated metanephrines, vanillylmandelic acid, and cortisol were normal. Right adrenalectomy with IVC thrombectomy was done. Perioperative period was uneventful. Histopathology of the mass turned out to be pheochromocytoma with thrombus revealing fibroadipose tissue with fibrin. Pheochromocytoma may present with IVC thrombus as well as normal serum and urinary markers. Thus, clinical suspicion is imperative in perioperative management of adrenal mass.

  10. Indications, management, and complications of temporary inferior vena cava filters

    International Nuclear Information System (INIS)

    Linsenmaier, Ulrich; Rieger, Johannes; Schenk, Franz; Rock, Clemens; Mangel, Eugen; Pfeifer, Klaus Juergen

    1998-01-01

    Purpose: We describe the results of a preliminary prospective study using different recently developed temporary and retrievable inferior vena cava (IVC) filters.Methods: Fifty temporary IVC filters (Guenther, Guenther Tulip, Antheor) were inserted in 47 patients when the required period of protection against pulmonary embolism (PE) was estimated to be less than 2 weeks. The indications were documented deep vein thrombosis (DVT) and temporary contraindications for anticoagulation, a high risk for PE, and PE despite DVT prophylaxis.Results: Filters were removed 1-12 days after placement and nine (18%) had captured thrombi. Complications were one PE during and after removal of a filter, two minor filter migrations, and one IVC thrombosis.Conclusion: Temporary filters are effective in trapping clots and protecting against PE, and the complication rate does not exceed that of permanent filters. They are an alternative when protection from PE is required temporarily, and should be considered in patients with a normal life expectancy.

  11. Percutaneous placement of bird's nest inferior vena cava filter

    International Nuclear Information System (INIS)

    Lee, Seung Hoon; Sung, Kyu Bo; Yoon, Hyun Ki

    1999-01-01

    To describe clinical experiences of the use of Bird's Nest inferior vena cava(IVC) filter. Between August 1991 and August 1997, IVC filter was percutaneously inserted in 51 patients with pulmonary embolism(PE) and deep vein thrombosis of the lower extremities. Indications for the placement of this filter were contraindication to anticoagulation in 17 patients, prophylaxis of PE in 17, failed anticoagulation in 11, massive PE with residual floating thrombus in three and complications involving anticoagulation in 3. In order to delineate the location of renal vein and extension of deep vein thrombosis into the IVC, all patients under went inferior vena cavography before filter placement. Thirty filters were inserted through the right femoral vein, 19 through the right internal jugular vein and three through the left femoral vein. The patients involved were followed up for periods ranging from one week to six years (mean 10 months). A Bird's Nest IVC filter was placed in the infrarenal IVC in 44 patients and in the suprarenal IVC in 7. Certain complicatioins ensued. IVC penetration occurred in three patients(5.9%), and in seven(1.37%) the filter wire prolapsed. Except for transient pain, however, there were no serious IVC penetration-related complications and no evidence of recurrence of PE in the cases involving prolapse of the filter wire. During follow up, clinically suspected recurrent PE was noted in two patients(3.9%), but there was no evidence of newly developed occlusion of the IVC. In patients who under went follow up, Bird's Nest IVC filter effectively prevented the development and recurrence of PE, and there were no complications. To prevent of penetration of the IVC and prolapse of the filter, however, technical skill was needed

  12. Primary research on direct multi-slice spiral CT venography in inferior vena cava

    International Nuclear Information System (INIS)

    Gong Peiyou; Liu Fengli; Ma Xianying; Zhao Li; Wang Liping; Li Xuehua; Li Jian

    2010-01-01

    Objective: To investigate the superiority of direct multi-slice spiral CT venography in inferior vena cava. Methods: Twenty-eight patients performed MSCT venography in inferior vena cava, including 2 cases with both indirect and direct venography, 10 cases with indirect venography, 20 cases with direct venography through unilateral or bilateral lower extremity venous injection. The image quality and enhancement degree of the inferior vena cava were compared in double-blind method. Results: Of 10 cases with indirect venography of inferior vena cava, 1 case was failed due to mild enhancement in inferior vena cava. Image quality was good in 2 cases, poor in 7 cases, no excellent case. Of 20 cases with direct venography of inferior vena cava, the enhancement degree was scored 1, 2 degree in 16, 4 cases respectively and no case was scored 3 degree, the image quality was excellent, good in 16, 4 cases and no case was bad. The success rate was 100%. Conclusion: The image quality of direct MSCT venography in inferior vena cava is better than that of indirect method. (authors)

  13. Bilateral inferior vena cava filter insertion in a patient with duplication of the infrarenal vena cava.

    LENUS (Irish Health Repository)

    Leong, S

    2010-06-19

    BACKGROUND: Inferior vena cava (IVC) filter insertion is a commonly performed procedure for indications such as recurrent pulmonary emboli or contraindication to anticoagulation. Symptomatic duplication of the IVC is exceedingly rare with only a handful of cases being described in the literature. AIM: We report an unusual case of a patient with symptomatic duplication of the IVC. RESULT: A 53-year-old woman presented at our hospital for resection of a cerebral metastasis from a non-small cell lung cancer following a recent diagnosis of bilateral lower limb deep venous thrombosis. This required perioperative reversal of anticoagulation and IVC filter insertion. Conventional venography performed during filter insertion documented the existence of a duplicated IVC. CONCLUSION: We present a case of a symptomatic duplication of the IVC requiring filter insertion. We review the developmental anatomy of the IVC along with the diagnostic findings and management strategies available.

  14. Creation of the permanent inferior vena cava filter for prevention of pulmonary artery embolism

    Directory of Open Access Journals (Sweden)

    Yа.O. Povar

    2016-05-01

    Full Text Available The aim of the study was to create a new permanent cava filter to improve functional capacities of the construction and achieve high clinical parameters. A new geometry of the permanent inferior vena cava filter was presented which has high blood clot-capturing ability, does not cause thrombus fragmentation, makes migration impossible. The inferior vena cava filter does not injure the vessel wall and preserves integrity under long-term use. The inferior vena cava filter installation is safe and controllable, the filter self-positioning and reposition are possible, the delivery system size is 6F, the blood flow changing is minimal.

  15. Venous Thromboembolism After Removal of Retrievable Inferior Vena Cava Filters

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Tanaka, Osamu; Yoshimatsu, Rika; Miura, Hiroshi; Nishimura, Tsunehiko

    2010-01-01

    The purpose of this study was to examine the incidence of new or recurrent venous thromboembolism (VTE) after retrieval of inferior vena cava (IVC) filters and risk factors associated with such recurrence. Between March 2001 and September 2008, at our institution, implanted retrievable vena cava filters were retrieved in 76 patients. The incidence of new or recurrent VTE after retrieval was reviewed and numerous variables were analyzed to assess risk factors for redevelopment of VTE after filter retrieval. In 5 (6.6%) of the 76 patients, redevelopment or worsening of VTE was seen after retrieval of the filter. Three patients (4.0%) had recurrent deep venous thrombosis (DVT) in the lower extremities and 2 (2.6%) had development of pulmonary embolism, resulting in death. Although there was no significant difference in the incidence of new or recurrent VTE related to any risk factor investigated, a tendency for development of VTE after filter retrieval was higher in patients in whom DVT in the lower extremities had been so severe during filter implantation that interventional radiological therapies in addition to traditional anticoagulation therapies were required (40% in patients with recurrent VTE vs. 23% in those without VTE; p = 0.5866 according to Fisher's exact probability test) and in patients in whom DVT remained at the time of filter retrieval (60% in patients with recurrent VTE vs. 37% in those without VTE; p = 0.3637). In conclusion, new or recurrent VTE was rare after retrieval of IVC filters but was most likely to occur in patients who had severe DVT during filter implantation and/or in patients with a DVT that remained at the time of filter retrieval. We must point out that the fatality rate from PE after filter removal was high (2.6%).

  16. Deep Venous Thrombosis Associated With Inferior Vena Cava Abnormalities And Hypoplastic Kidney In Siblings

    Directory of Open Access Journals (Sweden)

    Duicu Carmen

    2016-06-01

    Full Text Available Congenital inferior vena cava anomalies have a reduced frequency in general population, many times being an asymptomatic finding. Patients caring such anomalies are at risk to develop deep vein thrombosis. In this paper, we present 2 siblings with deep venous thrombosis and inferior vena cava abnormalities, with a symptomatic onset at similar age. The inferior vena cava abnormality was documented by an angio-CT in each case. The thrombophilic workup was negative. Patients were treated with conservative therapy: low molecular weight heparin anticoagulants converted later to oral anticoagulant with resolution of symptoms and disappearance of the thrombus. Finally, in the absence of any risk factor in a young patient admitted with deep vein thrombosis investigations to exclude inferior vena cava anomalies are mandatory.

  17. Is there a relationship between the diameter of the inferior vena cava ...

    African Journals Online (AJOL)

    2015-04-12

    Apr 12, 2015 ... Key words: Central venous pressures, critically ill patients, inferior vena cava. Date of Acceptance: ... Regardless of the cause of the patient's status, the blood/ .... AUC=Area under ROC curve, IAP=Anteroposterior diameter of.

  18. Inferior vena cava filter penetration following Whipple surgical procedure causing ureteral injury.

    Science.gov (United States)

    Abdel-Aal, Ahmed Kamel; Ezzeldin, Islam B; Moustafa, Amr Soliman; Ertel, Nathan; Oser, Rachel

    2015-12-01

    We report a case of an indwelling inferior vena cava filter that penetrated the IVC wall after Whipple's pancreatico-duodenectomy procedure performed in a patient with ampullary carcinoma, resulting in right ureteral injury and obstruction with subsequent hydroureter and hydronephrosis. This was incidentally discovered on a computed tomography scan performed as routine follow up to evaluate the results of the surgery. We retrieved the inferior vena cava filter and placed a nephrostomy catheter to relieve the ureteral obstruction. Our case highlights the importance of careful inferior vena cava manipulation during abdominal surgery in the presence of an inferior vena cava filter, and the option of temporary removal of the filter to be placed again after surgery in order to avoid this complication, unless protection is required against clot migration during the surgical procedure.

  19. Retrocaval ureter and anomalies of inferior vena cava

    International Nuclear Information System (INIS)

    Tsubogo, Yoshitaka; Hiraoka, Hisaki; Tonariya, Yoshito; Miyamae, Tatsuya; Fujioka, Mutsumi

    1980-01-01

    We report two cases of retrocaval ureter: one with the usual hook-shaped pattern of the course of ureter (Type 1 according to Kenawi and Williams) and the other with the ureter medially displaced in a large curving fashion without kinking or obstruction. (Type 2). The second case was diagnosed on CT without resorting to any invasive procedure. It can be classified as Type 2 of Kenawi and Williams because of the absence of obstruction and kinking of ureter. The first case is associated with a complicated anomaly of inferior vena cava previously not reported which shows the duplication of infrarenal segment of cava with azygos continuation via the right persistent supracardinal vein. This anomaly is also complicated by the persistent posterior cardinal vein which is continuous with the normal prerenal segment of cava after receiving the right renal vein. This persistent posterior cardinal vein is the cause of retrocaval ureter in this case. It is also stressed that the knowledge of various caval anomalies is important in the interpretation of CT. (author)

  20. Radiological evidence of double inferior vena cava in a young adult male

    International Nuclear Information System (INIS)

    Nevruz, O.; Ural, U.; Kirici, Y.; Kilic, C.; Bozlar, U.

    2007-01-01

    The development of the inferior vena cava IVC is a complex process comprising the formation and regression of some anastomoses, so various anomalies may occur during embryogenesis. These variations can increase the difficulty of aneurysm resection as well as the risk of venous injury and subsequent excessive bleeding during retroperitoneal and thoracic surgical interventions. Here, we report a patient with double inferior vena cava by radiographically during his investigation for the etiology of pancytopenia. (author)

  1. Spontaneous tilting after placement of the gunther-tulip inferior vena caval filter: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok; Cha, In Ho; Seol, Hae Young; Park, Cheol Min [Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2006-10-15

    Tilting of a deployed filter in the inferior vena cava (IVC) is a particular kind of periprocedural complication and this can reduce the filter's clot-trapping ability and increase the occlusion of the IVC at a later period. The authors report here on a case of spontaneous tilting of an inferior vena caval filter that was associated with thrombosis in the IVC within 2 weeks of the initially successful placement of the filter without tilting.

  2. Spontaneous tilting after placement of the gunther-tulip inferior vena caval filter: a case report

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Cha, In Ho; Seol, Hae Young; Park, Cheol Min

    2006-01-01

    Tilting of a deployed filter in the inferior vena cava (IVC) is a particular kind of periprocedural complication and this can reduce the filter's clot-trapping ability and increase the occlusion of the IVC at a later period. The authors report here on a case of spontaneous tilting of an inferior vena caval filter that was associated with thrombosis in the IVC within 2 weeks of the initially successful placement of the filter without tilting

  3. CT diagnosis of tumor thrombus of the renal vein and inferior vena cava

    International Nuclear Information System (INIS)

    Masuda, Fujio; Chen, Zuicho; Oishi, Yukihiko; Machida, Toyohei

    1980-01-01

    We used computed tomography (CT) for diagnosis in 4 cases of renal tumor associated with tumor thrombus of the renal vein and inferior vana cava. The results obtained are described below: A total of 4 cases consisting of 3 cases of renal cell carcinoma and one case of squamous cell carcinoma of the renal pelvis, treated at the Jikei University Hospital during the six months period from January to June of 1979, were studied. The affected side was right in 3 cases and left in one case. In all of the former cases the tumor thrombus was extending from the renal vein to the inferior vena cava, while in the latter case it was confined in the renal vein. All these 4 cases received CT together with renal arteriography and inferior venacavography, followed by nephrectomy, and were confirmed of the presence of tumor thrombus in the renal vein and inferior vena cava operatively. CT findings revealed a pronounced enlargement of the renal vein, and tumor thrombus of the renal vein was diagnosed in all of the 4 cases. In 2 of 3 cases in which tumor thrombus extended to the inferior vena cava, the dilated renal vein was found to be connected to the slightly dilated inferior vena cava, while in the remaining one case the outline of the inferior vena cava was obscure, showing no clear dilatation. After contrast enhancement, a filling defect was seen in the inferior vena cava. CT findings of tumor thrombus in the vein indicated a dilatation of the renal vein and inferior vena cava. In addition, a filling defect was found after contrast enhancement, suggesting that CT is helpful as a diagnostic aid. (author)

  4. Retrievable Inferior Vena Cava Filters: Factors that Affect Retrieval Success

    Energy Technology Data Exchange (ETDEWEB)

    Geisbuesch, Philipp, E-mail: philippgeisbuesch@gmx.de; Benenati, James F.; Pena, Constantino S.; Couvillon, Joseph; Powell, Alex; Gandhi, Ripal; Samuels, Shaun; Uthoff, Heiko [Baptist Cardiac and Vascular Institute, Division of Vascular and Interventional Radiology (United States)

    2012-10-15

    Purpose: To report and analyze the indications, procedural success, and complications of retrievable inferior vena cava filters (rIVCF) placement and to identify parameters that influence retrieval attempt and failure. Methods: Between January 2005 and December 2010, a total of 200 patients (80 men, median age 67 years, range 11-95 years) received a rIVCF with the clinical possibility that it could be removed. All patients with rIVCF were prospectively entered into a database and followed until retrieval or a decision not to retrieve the filter was made. A retrospective analysis of this database was performed. Results: Sixty-one percent of patients had an accepted indication for filter placement; 39% of patients had a relative indication. There was a tendency toward a higher retrieval rate in patients with relative indications (40% vs. 55%, P = 0.076). Filter placement was technically successful in all patients, with no procedure-related mortality. The retrieval rate was 53%. Patient age of >80 years (odds ratio [OR] 0.056, P > 0.0001) and presence of malignancy (OR 0.303, P = 0.003) was associated with a significantly reduced probability for attempted retrieval. Retrieval failure occurred in 7% (6 of 91) of all retrieval attempts. A time interval of > 90 days between implantation and attempted retrieval was associated with retrieval failure (OR 19.8, P = 0.009). Conclusions: Patient age >80 years and a history of malignancy are predictors of a reduced probability for retrieval attempt. The rate of retrieval failure is low and seems to be associated with a time interval of >90 days between filter placement and retrieval.

  5. Retrievable Inferior Vena Cava Filters: Factors that Affect Retrieval Success

    International Nuclear Information System (INIS)

    Geisbüsch, Philipp; Benenati, James F.; Peña, Constantino S.; Couvillon, Joseph; Powell, Alex; Gandhi, Ripal; Samuels, Shaun; Uthoff, Heiko

    2012-01-01

    Purpose: To report and analyze the indications, procedural success, and complications of retrievable inferior vena cava filters (rIVCF) placement and to identify parameters that influence retrieval attempt and failure. Methods: Between January 2005 and December 2010, a total of 200 patients (80 men, median age 67 years, range 11–95 years) received a rIVCF with the clinical possibility that it could be removed. All patients with rIVCF were prospectively entered into a database and followed until retrieval or a decision not to retrieve the filter was made. A retrospective analysis of this database was performed. Results: Sixty-one percent of patients had an accepted indication for filter placement; 39% of patients had a relative indication. There was a tendency toward a higher retrieval rate in patients with relative indications (40% vs. 55%, P = 0.076). Filter placement was technically successful in all patients, with no procedure-related mortality. The retrieval rate was 53%. Patient age of >80 years (odds ratio [OR] 0.056, P > 0.0001) and presence of malignancy (OR 0.303, P = 0.003) was associated with a significantly reduced probability for attempted retrieval. Retrieval failure occurred in 7% (6 of 91) of all retrieval attempts. A time interval of > 90 days between implantation and attempted retrieval was associated with retrieval failure (OR 19.8, P = 0.009). Conclusions: Patient age >80 years and a history of malignancy are predictors of a reduced probability for retrieval attempt. The rate of retrieval failure is low and seems to be associated with a time interval of >90 days between filter placement and retrieval.

  6. Inferior vena cava segmentation with parameter propagation and graph cut.

    Science.gov (United States)

    Yan, Zixu; Chen, Feng; Wu, Fa; Kong, Dexing

    2017-09-01

    The inferior vena cava (IVC) is one of the vital veins inside the human body. Accurate segmentation of the IVC from contrast-enhanced CT images is of great importance. This extraction not only helps the physician understand its quantitative features such as blood flow and volume, but also it is helpful during the hepatic preoperative planning. However, manual delineation of the IVC is time-consuming and poorly reproducible. In this paper, we propose a novel method to segment the IVC with minimal user interaction. The proposed method performs the segmentation block by block between user-specified beginning and end masks. At each stage, the proposed method builds the segmentation model based on information from image regional appearances, image boundaries, and a prior shape. The intensity range and the prior shape for this segmentation model are estimated based on the segmentation result from the last block, or from user- specified beginning mask if at first stage. Then, the proposed method minimizes the energy function and generates the segmentation result for current block using graph cut. Finally, a backward tracking step from the end of the IVC is performed if necessary. We have tested our method on 20 clinical datasets and compared our method to three other vessel extraction approaches. The evaluation was performed using three quantitative metrics: the Dice coefficient (Dice), the mean symmetric distance (MSD), and the Hausdorff distance (MaxD). The proposed method has achieved a Dice of [Formula: see text], an MSD of [Formula: see text] mm, and a MaxD of [Formula: see text] mm, respectively, in our experiments. The proposed approach can achieve a sound performance with a relatively low computational cost and a minimal user interaction. The proposed algorithm has high potential to be applied for the clinical applications in the future.

  7. Study of 99Tcm-annexin V distribution in inferior vena cava thrombus models of rabbits

    International Nuclear Information System (INIS)

    Wu Dayong; Zhang Wenyan; Bian Yanzhu; Hu Yujing

    2013-01-01

    To study 99 Tc m -Annexin V distribution in inferior vena cava thrombus models of rabbits and uptake of 99 Tc m -Annexin V in fresh and old venous thrombus. Rabbits (n=15) were randomly grouped into 3 groups (the fresh thrombus group, old thrombus group, and control group). The rabbits of two thrombus groups developed inferior vena cava thrombus models by operations. The control group received sham operation. The fresh thrombus group and control group rabbits were injected 99 Tc m -Annexin V after operating 1 d; the old thrombus group 14 d. After 1 h all rabbits were killed by injecting overdose pentobarbital sodium. The thrombus (or the inferior vena cava about 3 cm below inferior pole of right kidney level in the control group rabbits), blood, thrombus area inferior vena cava, head lateral inferior vena cava (except the control group), thigh muscle, stomach, myocardium, pulmonary, liver, kidney, spleen, bone and small intestine were obtained from all group rabbits. The ex tissue and blood were weighed and measured by a Well-type detector. The percentage of the injected dose per gram of ex tissue (or blood) was calculated by the above data. The thrombus to blood, thrombus area inferior vena cava, head lateral inferior vena cava and thigh muscle ratios were calculated by percentage of the injected dose per gram of ex tissue (or blood). The test was used to compare the fresh thrombus group and old thrombus group by SPSS 17.0. The percentage of' the injected dose per gram of thrombi (0.01894± 0.002 16% ID/g) in the fresh thrombus group was higher than the old thrombus group (0.00473±0.001 28% ID/g), P<0.05. The thrombus to blood, thrombus area inferior vena cava, head lateral inferior vena cava and muscle ratios (3.42±1.06, 26.32±13.60, 31.23 ±16.00, 111.62±52.23) in the fresh thrombus group were higher than the old thrombus group (0.98±0.09, 5.12±2.01, 6.25±2.38, 21.82±5.93), P<0.05 for all. All the thrombi of the fresh thrombus group were confirmed

  8. Hepatic Scintigraphic Findings of Budd-Chiari Syndrome due to Inferior Vena Caval Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hoon; Chung, Soo Kyo; Byun, Jae Young; Lee, Sung Yong; Shinn, Kyung Sub; Kim, Choon Yul; Bahk, Yong Whee [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1988-03-15

    Budd-Chiari syndrome (BCS) is a rare clinical entity characterized by post-sinusoidal portal hypertension caused by the obstruction to the hepatic vein outflow. The diagnosis is suggested by hepatic scintigraphy and is usually confirmed by hepatic venography, inferior vena cavography and biopsy. The scintigraphic finding of BCS caused by the obstruction of main hepatic vein has been reported to consist typically of hypertrophy of the caudate lobe with increased radionuclide accumulation. Such a typical finding has been accounted for by the fact that the venous outflow from the caudate lobe is preserved when the main hepatic vein is obstructed. But usually, the hepatic venous outflow from the caudate lobe is also obstructed in BCS due to inferior vena caval obstruction. So hepatic scintigraphic findings of BCS due to inferior vena caval obstruction show different findings as compared with the BCS due to hepatic vein obstruction. We evaluate the hepatic scintigrams of the 13 cases of BCS due to inferior vena caval obstruction and review the literatures. The results are as follows: 1) We cannot observe the caudate lobe hypertrophy with increased uptake, which is known as a classic finding in BCS due to hepatic vein obstruction. 2) The most prominent hepatic scintigraphic findings of BCS are nonhomogenous uptake in the liver with extrahepatic uptake in the all cases. 3) We can see cold areas at the superior aspect of right hepatic lobe in 7 cases (54%). This is a useful finding suggesting BCS due to inferior vena caval obstruction.

  9. Hepatic Scintigraphic Findings of Budd-Chiari Syndrome due to Inferior Vena Caval Obstruction

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chung, Soo Kyo; Byun, Jae Young; Lee, Sung Yong; Shinn, Kyung Sub; Kim, Choon Yul; Bahk, Yong Whee

    1988-01-01

    Budd-Chiari syndrome (BCS) is a rare clinical entity characterized by post-sinusoidal portal hypertension caused by the obstruction to the hepatic vein outflow. The diagnosis is suggested by hepatic scintigraphy and is usually confirmed by hepatic venography, inferior vena cavography and biopsy. The scintigraphic finding of BCS caused by the obstruction of main hepatic vein has been reported to consist typically of hypertrophy of the caudate lobe with increased radionuclide accumulation. Such a typical finding has been accounted for by the fact that the venous outflow from the caudate lobe is preserved when the main hepatic vein is obstructed. But usually, the hepatic venous outflow from the caudate lobe is also obstructed in BCS due to inferior vena caval obstruction. So hepatic scintigraphic findings of BCS due to inferior vena caval obstruction show different findings as compared with the BCS due to hepatic vein obstruction. We evaluate the hepatic scintigrams of the 13 cases of BCS due to inferior vena caval obstruction and review the literatures. The results are as follows: 1) We cannot observe the caudate lobe hypertrophy with increased uptake, which is known as a classic finding in BCS due to hepatic vein obstruction. 2) The most prominent hepatic scintigraphic findings of BCS are nonhomogenous uptake in the liver with extrahepatic uptake in the all cases. 3) We can see cold areas at the superior aspect of right hepatic lobe in 7 cases (54%). This is a useful finding suggesting BCS due to inferior vena caval obstruction.

  10. Outcome of inferior vena cava and noncaval venous leiomyosarcomas.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Calio', Francesco; Pacilè, Maria Antonietta; Masci, Federica; Vietri, Francesco

    2016-02-01

    Leiomyosarcoma (LMS) is a rare tumor arising from the smooth muscle cells of arteries and veins. LMS may affect both the inferior vena cava (IVC) and non-IVC veins. Because of its rarity, the experience with the outcome of the disease originating from the IVC compared with that with non-IVC offspring is overall limited. In this study, we compared the clinical features and outcomes after operative resection of IVC and non-IVC LMS to detect possible significant differences that could affect treatment and prognosis. Twenty-seven patients undergoing operative resection of a venous LMS at a single tertiary care center and one secondary care hospital were reviewed retrospectively and divided into 2 groups: IVC-LMS (Group A, n = 18) and non-IVC LMS (Group B, n = 9). As primary end points, postoperative mortality and morbidity, disease-specific survival and, if applicable, patency of venous reconstruction were considered. Bivariate differences were compared with the χ(2) test. Disease-specific survival was expressed by a life-table analysis and compared using the log-rank test. No postoperative mortality was observed in either group. Postoperative morbidity was 28% in group A and 11% in group B (P = .33). The mean duration of follow-up was 60 months (range, 13-140). Disease-specific survival was 60% in group A and 75% in group B at 3 years (P = .48), and it was 54% in group A and 62% in group B at 5 years (P = .63). Seven grafts were occluded in group A (39%) and 1of 3 were occluded in group B (33%) (P = .85). IVC and non-IVC LMS exhibit similar outcomes in terms of postoperative course and survival. Operative resection associated with vascular reconstruction, if applicable, eventually followed by radiation and chemotherapy may be curative and is associated with good functional results. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Diagnosis of tricuspid insufficiency by Doppler flowmetry in the inferior vena cava

    International Nuclear Information System (INIS)

    Smith, H.J.

    1986-01-01

    Eighty-five patients subjected to routine heart catheterization were examined with duplex scanning of the inferior vena cava. Adequate Doppler recordings and a right ventricular angiography were obtained in 79 of them. Tricuspid insufficiency was found to be present in 34 patients at angiography and in 24 at duplex examination. No false positive Doppler diagnoses of tricuspid insufficiency occurred. The possibility of false positive angiographic diagnoses is discussed. A high correlation was found between percentage reversed flow in the inferior vena cava during ventricular systole and degree of angiographic tricuspid insufficiency. It is concluded that duplex scanning of the inferior vena cava seems to be a good alternative to angiography in the diagnosis and quantification of tricuspid insufficiency. (orig.)

  12. Inferior vena cava leiomyosarcoma: vascular reconstruction is not ...

    African Journals Online (AJOL)

    ... vena cava is a rare and aggressive tumor, arising from the smooth muscle cells in the vessel wall. A large complete surgical resection is the essential treatment. The need of vascular reconstruction is not always mandatory. It's above all to understand the place of the reconstruction with artificial vascular patch prosthetics of ...

  13. Hepatic Veins and Inferior Vena Cava Thrombosis in a Child Treated by Transjugular Intrahepatic Portosystemic Shunt

    International Nuclear Information System (INIS)

    Carnevale, Francisco Cesar; Santos, Aline Cristine Barbosa; Tannuri, Uenis; Cerri, Giovanni Guido

    2010-01-01

    We report the case of a 9-year-old boy with portal hypertension, due to Budd-Chiari syndrome, and retrohepatic inferior vena cava thrombosis, submitted to a transjugular intrahepatic portosystemic shunt (TIPS) by connecting the suprahepatic segment of the inferior vena cava directly to the portal vein. After 3 months, the withdrawal of anticoagulants promoted the thrombosis of the TIPS. At TIPS revision, thrombosis of the TIPS and the main portal vein and clots at the splenic and the superior mesenteric veins were found. Successful angiography treatment was performed by thrombolysis and balloon angioplasty of a severe stenosis at the distal edge of the stent.

  14. Retrievable Inferior vena cava filters in pregnancy: Risk versus benefit?

    Science.gov (United States)

    Crosby, David A; Ryan, Kevin; McEniff, Niall; Dicker, Patrick; Regan, Carmen; Lynch, Caoimhe; Byrne, Bridgette

    2018-03-01

    Venous thromboembolism remains one of the leading causes of maternal mortality in the developed world. Retrievable inferior vena cava (IVC) filters have a role in the prevention of lethal pulmonary emboli when anticoagulation is contraindicated or has failed [1]. It is unclear whether or not the physiological changes in pregnancy influence efficacy and complications of these devices. The decision to place an IVC filter in pregnancy is complex and there is limited information in terms of benefit and risk to the mother. The objective of this study was to determine the efficacy and safety of these devices in pregnancy and to compare these with rates reported in the general population. The aim of this study was report three recent cases of retrievable IVC filter use in pregnant women in our department and to perform a systematic review of the literature to identify published cases of filters in pregnancy. The efficacy and complication rates of these devices in pregnancy were estimated and compared to rates reported in the general population in a recent review [2]. Fisher's exact test was used for statistical analysis. In addition to our three cases, 16 publications were identified with retrievable IVC filter use in 40 pregnant women resulting in a total of 43 cases. There was no pulmonary embolus in the pregnant group (0/43) compared to 57/6291 (0.9%) in the general population. Thrombosis of the filter (2.3% vs. 0.9%, p = 0.33) and perforation of the IVC (7.0% vs 4.4%, p = 0.44) were more common in pregnancy compared to the general population but the difference was not statistically significant. Failure to retrieve the filter is more likely to occur in pregnancy (26% vs. 11%, p = 0.006) but this did not correlate with the type of device (p = 0.61), duration of insertion (p = 0.58) or mode of delivery (p = 0.37). Data for retrievable IVC filters in pregnancy is limited and there may be a publication bias towards complicated cases. This study

  15. Successful Percutaneous Retrieval of an Inferior Vena Cava Filter Migrating to the Right Ventricle in a Bariatric Patient

    International Nuclear Information System (INIS)

    Veerapong, Jula; Wahlgren, Carl Magnus; Jolly, Neeraj; Bassiouny, Hisham

    2008-01-01

    The use of an inferior vena cava filter has an important role in the management of patients who are at high risk for development of pulmonary embolism. Migration is a rare but known complication of inferior vena cava filter placement. We herein describe a case of a prophylactic retrievable vena cava filter migrating to the right ventricle in a bariatric patient. The filter was retrieved percutaneously by transjugular approach and the patient did well postoperatively. A review of the current literature is given.

  16. Abdominal wall phlebitis due to Prevotella bivia following renal transplantation in a patient with an occluded inferior vena cava

    NARCIS (Netherlands)

    Janssen, S.; van Donselaar-van der Pant, K. A. M. I.; van der Weerd, N. C.; Develter, W.; Bemelman, F. J.; Grobusch, M. P.; Idu, M. M.; ten Berge, I. J. M.

    2013-01-01

    Pre-existing occlusion of the inferior vena cava may complicate renal transplantation. Suppurative abdominal wall phlebitis following renal transplantation was diagnosed in a patient with pre-existing thrombosis of the inferior vena cava of unknown cause. The phlebitis developed in the subcutaneous

  17. Comparison of superior vena caval and inferior vena caval access using a radioisotope technique during normal perfusion and cardiopulmonary resuscitation

    International Nuclear Information System (INIS)

    Dalsey, W.C.; Barsan, W.G.; Joyce, S.M.; Hedges, J.R.; Lukes, S.J.; Doan, L.A.

    1984-01-01

    Recent studies of thoracic pressure changes during external cardiopulmonary resuscitation (CPR) suggest that there may be a significant difference in the rate of delivery of intravenous drugs when they are administered through the extrathoracic inferior vena cava (IVC) rather than the intrathoracic superior vena cava (SVC). Comparison of delivery of a radionuclide given using superior and inferior vena caval access sites was made during normal blood flow and during CPR. Mean times from injection to peak emission count in each ventricle were determined. There were no significant differences between mean peak times for SVC or IVC routes during normal flow or CPR. When peak times were corrected for variations in cardiac output, there were no significant differences between IVC and SVC peak times during normal flow. During CPR, however, mean left ventricular peak time, when corrected for cardiac output, was significantly shorter (P less than .05) when the SVC route was used. The mean time for the counts to reach half the ventricular peak was statistically shorter (P less than .05) in both ventricles with the SVC route during the low flow of CPR. This suggests that during CPR, increased drug dispersion may occur when drugs are infused by the IVC route and thus may modify the anticipated effect of the drug bolus. These results suggest that during CPR, both the cardiac output and the choice of venous access are important variables for drug delivery

  18. Experimental study of domestic inferior vena cava filter comparative to Antheor temporary vena cava filter in vitro

    International Nuclear Information System (INIS)

    Chen Guoping; Gu Jianping; Lou Wensheng; He Xu; Chen Liang; Su Haobo

    2007-01-01

    Objective: To evaluate clot capturing efficacy and stability of a new domestic designed inferior vena cava filter (DDIVCF) by comparing with Anthem temporary vena cava filter in vitro. Methods: (1)The DDIVCF and Antheor filter were tested in a flow model simulated the inferior vena cava (IVC) with 20 mm and 25 mm in diameter. The swine clots of four sizes were used: 3 mm x 20 mm, 3 mm x 30 mm, 6 mm x 20 mm, 6 mm x 30 mm. The clot capturing capacity was observed in horizontal position. (2) The stability was observed by measuring the comparative moving distance of 6 mm x 30 mm clots after clot trapping. Results: (1) DDIVCF capture rates were 34%, 56%, 82%, 94% and 26%, 38%, 56%, 86% for the 20 mm and 25 mm IVC models of four different sizes clots respectively, comparing with 54%, 64%, 86%, 96% and 38%, 44%, 68%, 90% respectively of Anthem temporary vena cava filter. The capture rates of DDIVCF and Antheor filter showed no significant differences of 3 mm x 30 mm, 6mm x 20 mm and 6 mm x 30 mm clots in 20 mm and 25 mm IVC models (P>0.05). (2) There was a few caudal migration with no significant difference (P>0.05). The filter migration distances were (0.6±0.3) cm and (1.0±0.1) cm respectively in the 20 mm and 25 mm IVC models with most clots of 6 mm x 30 mm were captured, comparing with (0.4±0.1) cm and (0.8 ±0.3) cm respectively for Antheor filter. Conclusions: DDIVCF is a stable and effective filter in an in-vitro model experiment but application in vivo would rather be further evaluated through more animal experiments. (authors)

  19. Patent abdominal subcutaneous veins caused by congenital absence of the inferior vena cava: a case report

    Directory of Open Access Journals (Sweden)

    Lipp Rainer W

    2010-07-01

    Full Text Available Abstract Introduction Patent paraumbilical and abdominal subcutaneous veins are found frequently as collaterals in patients due to portal hypertension mainly in liver cirrhosis. Case presentation For evaluation of portal hypertension in a 72-year-old Caucasian man without liver cirrhosis, magnetic resonance imaging with gadolinium contrast-enhancement was performed and demonstrated a missing inferior vena cava. A blood return from the lower extremities was shown through enlarged collateral veins of the abdominal wall, vena azygos and hemiazygos continuation, and multiple liver veins emptying into the right cardiac atrium. We describe a rare case of abdominal subcutaneous wall veins as collaterals caused by a congenitally absent infrarenal inferior vena cava with preservation of a hypoplastic suprarenal segment. Conclusion Knowledge of these congenital variations can be of clinical importance and it is imperative for the reporting radiologist to identify these anomalies as they can have a significant impact on the clinical management of the patient.

  20. Umbilical vein draining into the inferior vena cava via the internal iliac vein, bypassing the liver

    International Nuclear Information System (INIS)

    Currarino, G.; Stannard, M.W.; Texas Univ., Dallas, TX; Kolni, H.

    1991-01-01

    This is the third report of an anomalous umbilical vein draining ectopically in a left pelvic vein, probably the left internal iliac, and through the inferior vena cava into the right atrium. The anomaly was encountered in a newborn infant with nonimmune hydrops fetalis, hypertrophic cardiomyopathy, multiorgan failure and possibly Noonan Syndrome. (orig.)

  1. Bird's Nest Filter Causing Symptomatic Hydronephrosis Following Transmural Penetration of the Inferior Vena Cava

    International Nuclear Information System (INIS)

    Stacey, C.S.; Manhire, A.R.; Rose, D.H.; Bishop, M.C.

    2004-01-01

    We report a case of symptomatic hydronephrosis caused by transcaval penetration of a Bird's Nest filter. Perforation of the wall of the inferior vena cava (IVC) following insertion of a caval filter is a well-recognized complication. Whilst two cases of hydronephrosis have been described with Greenfield filters, no case involving a Bird's Nest filter has been reported previously

  2. Transection of the inferior vena cava from blunt thoracic trauma: case reports.

    Science.gov (United States)

    Peitzman, A B; Udekwu, A O; Pevec, W; Albrink, M

    1989-04-01

    Blunt thoracic trauma is a frequent cause of death in multiple trauma victims. Myocardial rupture may occur in up to 65% of patients who die with thoracic injuries. Two cases are presented with intrapericardial transection of the inferior vena cava, pericardial rupture, and myocardial rupture from blunt thoracic trauma. Both patients died.

  3. Umbilical vein draining into the inferior vena cava via the internal iliac vein, bypassing the liver

    Energy Technology Data Exchange (ETDEWEB)

    Currarino, G.; Stannard, M.W. (Children' s Medical Center, Dallas, TX (United States). Dept. of Radiology Texas Univ., Dallas, TX (United States). Southwestern Medical Center); Kolni, H. (Methodist Hospital, Dallas, TX (United States). Dept. of Pediatrics)

    1991-05-01

    This is the third report of an anomalous umbilical vein draining ectopically in a left pelvic vein, probably the left internal iliac, and through the inferior vena cava into the right atrium. The anomaly was encountered in a newborn infant with nonimmune hydrops fetalis, hypertrophic cardiomyopathy, multiorgan failure and possibly Noonan Syndrome. (orig.).

  4. Deep venous thrombosis and agenesis of the intrahepatic segment of inferior vena cava

    International Nuclear Information System (INIS)

    Velasco, J.; Fernandez, M.M.; Manzanares, R.; Hernando, A.

    1997-01-01

    We present a case of agenesis of the intrahepatic segment of inferior vena cava (IVC) with drainage through the azygos and hemiazygos systems. The presenting sign was deep venous thrombosis (DVT) in both lower extremities. The different imaging studies led to the diagnosis of both the congenital and acquired venous abnormalities, which are discussed. (Author) 14 refs

  5. Haematogenous tumour growth in the inferior vena cava in a patient with a nonseminomatous testicular tumour

    NARCIS (Netherlands)

    Ham, S J; Koops, H Schraffordt; Sleijfer, D T; Freling, N M; Molenaar, W M

    1991-01-01

    The case history is reported of a patient with an invasion of the inferior vena cava by metastases of a non-seminomatous testicular tumour. He was treated with combination chemotherapy, followed by laparotomy and resection of residual tumour tissue. Fourteen months after this operation he is in good

  6. Septic thrombosis of the inferior vena cava treated with percutaneous mechanical thrombectomy

    NARCIS (Netherlands)

    Burgmans, Mark C.; Rommes, Johannes H.; Spronk, Peter E.; van Nidek, Robert J. P. Brouerius; Bouma, Wim H.; Gratama, Jan Willem C.

    2006-01-01

    The present report describes a patient with septic thrombosis of the inferior vena cava (IVC) related to a subhepatic abscess adjacent to the IVC. Despite prolonged antimicrobial therapy and systemic anticoagulation, sepsis and septic embolism persisted while the size of the thrombus increased.

  7. Right-sided duplication of the inferior vena cava and the common iliac vein: hidden hinds in spiral-computed tomography; Rechtsseitige Dopplung der Vena cava inferior und Vena iliaca communis: Bildgebung mit der Spiral-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, D.R.; Friedrich, M. [Krankenhaus am Urban (Germany). Abt. fuer Roentgendiagnostik und Nuklearmedizin; Andresen, R. [Staedtisches Krankenhaus Zehlendorf, Behring (Germany). Abt. fuer Roentgendiagnostik und Nuklearmedizin

    1998-05-01

    Duplications of the inferior vena cava (IVC) are rare variants of the abdominal vessels and are normally located on both sides of the abdominal aorta. The rare case of a rightsided infrarenal duplication of the IVC with involvement of the common iliac vein is reported. Details of the embryology are presented for the understanding of this IVC variant. The spiral CT with multiplanar reconstructions makes it possible to define the vascular morphology and to differentiate it from lymphoma. (orig.) [Deutsch] Duplikaturen der Vena cava inferior (VCI) sind seltene meist bilateral der Aorta abdominalis gelegene abdominelle Gefaessvarianten. Der ungewoehnliche Fall einer rechtsseitigen infrarenalen Dopplung der VCI mit Beteiligung der Vena iliaca communis wird dargestellt. Auf der Embryologie wird, soweit fuer das Verstaendnis der vorliegenden VCI-Variante notwendig, eingegangen. Die Spiral-CT mit multiplanaren Rekonstruktionen erlaubt die morphologische Beschreibung der Gefaesssituation und die Differenzierung gegenueber Lymphomen. (orig.)

  8. The initial experience of transjugular retrieval of Geunther Tulip inferior vena cava filters

    International Nuclear Information System (INIS)

    Xiao Liang; Shen Jing; Tong Jiajie; Li Haiwei; Xu Ke

    2011-01-01

    Objective: To explore the indications and technical procedures of transjugular retrieval of Geunther Tulip inferior vena cava filters. Methods: Seventy-four patients (40 males and 34 females with a mean age of 45.8 years) with acute lower extremity deep venous thrombosis encountered in our hospital from September 2007 to Mar 2009 were involved in this study. The onset of the disease was from one day to 14 days. Clinical symptoms included swelling, pain, cyanosis or pallescence of the affected limb with higher or normal skin temperature. Thirty-one patients who complicated with pulmonary embolism suffered from dyspnoea, chest pain, hemoptysis, etc. Implantation of Geunther Tulip retrievable inferior vena cava filters through femoral or right internal jugular vein was carried out, which was followed by intravenous transcatheter thrombolysis. Vascular ultrasound and angiography showed no fresh or free thrombus in 12-80 days after initial treatment, then the Geunther Tulip filter was taken out from right internal jugular vein, and inferior vena cavography was performed again. All patients accepted anticoagulation and antibiotic treatment for 3-5 days after operation. A follow-up lasting for 4-12 months was made. Results: Successful implantation of Geunther Tulip retrievable inferior vena cava filter with only one session was obtained in all 74 patients. During implantation procedure one filter became tilted 25 degrees. Successful removal of Geunther Tulip retrievable inferior vena cava filter was achieved in 40 patients in 41.3 days (12-80 days) after the filter was delivered, and the procedure cost only 5.8 minutes (1-115 minutes) with a successful rate of 97.6% (40/41). Failure of retrieval of IVC filter due to compact adhesion of the filter to IVC wall happened in one patient. Inferior vena cavography again confirmed that there was no any sign of vascular perforation or rupture. Retrieval of IVC filter was not performed in other 33 patients and no clinical

  9. Heart block and cardiac embolization of fractured inferior vena cava filter.

    Science.gov (United States)

    Abudayyeh, Islam; Takruri, Yessar; Weiner, Justin B

    2016-01-01

    A 66-year-old man underwent a placement of an inferior vena cava filter before a gastric surgery 9 years prior, presented to the emergency room with a complete atrioventricular block. Chest x-ray and transthoracic echocardiogram showed struts migrating to right ventricle with tricuspid regurgitation. Cardiothoracic surgery was consulted and declined an open surgical intervention due to the location of the embolized fragments and the patient's overall condition. It was also felt that the fragments had migrated chronically and were adhered to the cardiac structures. The patient underwent a dual-chamber permanent pacemaker implantation. Post-implant fluoroscopy showed no displacement of the inferior vena cava filter struts due to the pacemaker leads indicating that the filter fracture had likely been a chronic process. This case highlights a rare combination of complications related to inferior vena cava filter fractures and the importance of assessing for such fractures in chronic placements. Inferior vena cava filter placement for a duration greater than 1 month can be associated with filter fractures and strut migration which may lead to, although rare, serious or fatal complications such as complete atrioventricular conduction system disruption and valvular damage including significant tricuspid regurgitation. Assessing for inferior vena cava filter fractures in chronic filter placement is important to avoid such complications. When possible, retrieval of the filter should be considered in all patients outside the acute setting in order to avoid filter-related complications. Filter retrieval rates remain low even when a retrievable filter is in place and the patient no longer has a contraindication to anticoagulation.

  10. Reconstruction of a total avulsion of the hepatic veins and the suprahepatic inferior vena cava secondary to blunt thoracoabdominal trauma.

    Science.gov (United States)

    Kaemmerer, Daniel; Daffner, Wolfgang; Niwa, Martin; Kuntze, Thomas; Hommann, Merten

    2011-02-01

    Blunt injury to the inferior vena cava is a rare but dramatic event having a high mortality up to 80%. The mortality increases after total avulsion especially in combination with secondary intra-abdominal injuries. We report on a 15-year-old boy who sustained a blunt trauma with a total, partially covered avulsion of the hepatic veins and the suprahepatic inferior vena cava. We treated the patient under internal bypassing of the retrohepatic vena cava by using the heart-lung machine and reconstructed the hepatic veins and suprahepatic vena cava with a conduit made of pericard.

  11. Roentgenologic diagnosis of pulmonary veins pathologically inflowing into vena cava inferior

    International Nuclear Information System (INIS)

    Shumskij, V.I.; Konstantinova, N.V.; Fedorovich, Yu.N.

    1986-01-01

    The authors considered the problem of X-ray semiotics of the right inferior pulmonary vein pathologically inflowing in the vena cava inferior (4 patients) and the false syndrome of the ''Turkish sabre'' (1 patients). Among the patients there were 2 adults and 3 children. It was noted that the abnormal inflowing of the right lower lobe vein in the vena cava inferior was often combined with different types of heart diseases and defects of the major vessels, mainly with the defect of the interatrial septum, the open arterial canal and hypoplasia of the right pulmonary artery. Radiodiagnosis for this group of patients should incorporate, in addition to routine X-ray methods, angiographic investigation, and its volume in each case should be determined on an individual basis

  12. Agenesia de veia cava inferior associada à trombose venosa profunda Agenesis of inferior vena cava associated with deep venous thrombosis

    Directory of Open Access Journals (Sweden)

    Clovis Luis Konopka

    2010-09-01

    Full Text Available A agenesia da veia cava inferior é uma anomalia congênita rara, que foi recentemente identificada como um importante fator de risco para o desenvolvimento e a recorrência de trombose venosa profunda de membros inferiores em jovens. O objetivo deste trabalho foi relatar o caso de uma paciente que apresentou trombose venosa profunda dois meses após a realização de cirurgia de varizes. A angiotomografia computadorizada demonstrou a presença de anomalia venosa complexa com ausência da veia cava inferior.The agenesis of the inferior vena cava is a rare congenital anomaly, which was recently identified as an important risk factor for the development and recurrence of deep venous thrombosis especially in young people. The goal of this work was to report the case of a patient who presented deep venous thrombosis approximately two months after varicose vein surgery. The computerized angiotomography demonstrated the presence of a complex venous anomaly with absence of the inferior vena cava.

  13. TrapEase inferior vena cava filter placement: use of the subclavian vein.

    Science.gov (United States)

    Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A

    2004-01-01

    The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access

  14. Atypical leiomyoma arising in a hepatic vein with extension into the inferior vena cava and right atrium

    International Nuclear Information System (INIS)

    Dunlap, H.J.; Udjus, K.

    1990-01-01

    We report an atypical leiomyoma arising in a hepatic vein and extending into the inferior vena cava and right atrium in a fourteen year old boy. US, CT and MRI facilitated diagnosis and removal of this tumor. (orig.)

  15. Percutaneous transfemoral placement of inferior vena cava filter to prevent pulmonary embolism in patients with malignant tumor

    International Nuclear Information System (INIS)

    Hu Baoshan; Li Yong; Luo Pengfei

    2005-01-01

    Objective: To evaluate the effectiveness and safety of inserting an inferior vena cava filter to prevent the pulmonary embolism (PE) due to detachment of the thrombus in the lower extremities. Methods: Inferior vena cava filter were placed in 37 patients with malignant tumor and deep venous thrombosis from 1998 to 2004. Malignancy was confirmed by pathological or cellular biological examination in all cases. The episode of pulmonary embolism was monitored during a post-intervention follow-up. Results: All the filters were placed in the inferior vena cava safely via a percutaneous femoral venous access. No serious complications such as pulmonary embolism occurred during the follow-up periods. Conclusion: The inferior vena cava filter placement is an effective and safe procedure in preventing the pulmonary embolism in patients with malignant tumor and deep venous thrombosis. (authors)

  16. Thrombosis of the ileo-caval sector: puerperal thrombosis and agenesia thrombosis of the inferior vena cava

    International Nuclear Information System (INIS)

    Garcia Egea, Jorge; Lara Guerrero, Isabel; Fustero Aznar, Jose Miguel; Hermoso Cuenca, Vicente; Velez Lomana, Abel

    2011-01-01

    The thrombosis of the inferior vena cava account for around the 15% of the cases of deep venous thrombosis. This is the case of a puerperal primigravida with a cesarean section labor presenting with a thrombosis initially in the right ovarian vein and then extension to the inferior vena cava. Treatment included low molecular weight heparin in anticoagulant doses; rest with elevation of the extremities and elastic bandage. After a satisfactory process evolution with partial lysis of the thrombus, the oral anticoagulation with Acenocumarol for 6 months was started. The second patient, a man aged 73 with backgrounds of an operated hepatic hydatidosis, had a thrombosis of the infrarenal inferior vena cava and agenesia of retrohepatic segment of the inferior vena cava. The patient remains with anticoagulant treatment including Acenocumarol, elastic bandage and hygienic care. As sequela he had a postphlebitic syndrome and reworsening of the edema leading to its admission in two occasions.(author)

  17. Bilateral Deep Vein Thrombosis Associated with Inferior Vena Cava Agenesis in a Young Patient Manifesting as Low Back Pain

    Directory of Open Access Journals (Sweden)

    Felipe Langer

    2017-04-01

    Full Text Available Congenital absence of the inferior vena cava is a rare vascular anomaly, and most cases are asymptomatic. Nevertheless, patients with inferior vena cava malformations may have increased risk of deep venous thrombosis. Particularly, cases of bilateral deep venous thrombosis may arise owing to an insufficient collateral venous drainage from the lower limbs. We hereby describe a case of a previously healthy young male patient presenting with bilateral lower limb deep venous thrombosis as the initial clinical manifestation of congenital inferior vena cava agenesis. We conclude that in young patients presenting with deep venous thrombosis, especially when thrombosis occurs spontaneously, bilaterally, or recurrently, inferior vena cava anomalies should be thoroughly investigated and ruled out as appropriate.

  18. Reversal of flow in the inferior vena cava and hepatic veins on dynamic CT

    International Nuclear Information System (INIS)

    Lelij, H. van der; Mallens, W.M.C.

    1988-01-01

    A tricuspid insufficiency may not be clinically evident and may remain unknown to the clinician. The phenomenon of a reversal of inferior vena caval blood flow and hepatic veins is known to occur in tricuspid regurgitation from right ventricular angiography and duplex scanning. Demonstration of such a reversal flow on a dynamic CT scan, as in our case, has, to our knowledge, not as yet been reported

  19. The diagnostic importance of the recognition of the inferior Vena cava abnormalities on CT-examinations

    International Nuclear Information System (INIS)

    Gouliamos, A.; Striggaris, K.; Haliasos, N.; Vlahos, N.; Pontifex, G.

    1981-01-01

    Two unusual variations of the Vena cava inferior, as shown by CT examinations, are reported and characteristic X-rays, as well as CT scans, are presented. The first case shows an IVC course to the left of the aorta and the second case absence of the intrahepatic portion of the IVC with azygos continuation. Difficulties in the differential diagnosis are analyzed and discussed, both demonstrated by plain X-rays and CT scans. (orig.) [de

  20. Diagnostic importance of the recognition of the inferior Vena cava abnormalities on CT-examinations

    Energy Technology Data Exchange (ETDEWEB)

    Gouliamos, A.; Striggaris, K.; Haliasos, N.; Vlahos, N.; Pontifex, G.

    1981-09-01

    Two unusual variations of the Vena cava inferior, as shown by CT examinations, are reported and characteristic X-rays, as well as CT scans, are presented. The first case shows an IVC course to the left of the aorta and the second case absence of the intrahepatic portion of the IVC with azygos continuation. Difficulties in the differential diagnosis are analyzed and discussed, both demonstrated by plain X-rays and CT scans.

  1. Inferior Vena Cava and Renal Vein Thrombosis Associated with Thymic Carcinoma

    Directory of Open Access Journals (Sweden)

    Vlad Teodor Berbecar

    2017-01-01

    Full Text Available Thymic tumors are rare mediastinal tumors that can present with a wide variety of symptoms. They can cause distant manifestations and are frequently associated with paraneoplastic syndromes. In our case, we describe the evolution of a 68-year-old male whose first manifestation was thrombosis of the inferior vena cava and renal veins. Thrombosis of large abdominal veins is rare, especially without being associated with any other comorbidity or risk factors.

  2. Anomalous inferior vena cava in association with omphalocele: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Antoniou, E E.H. [Dept. of Pediatrics, School of Medicine, Univ. of Tokushima (Japan); Matsuoka, S [Dept. of Pediatrics, School of Medicine, Univ. of Tokushima (Japan); Mori, K [Dept. of Pediatrics, School of Medicine, Univ. of Tokushima (Japan); Hayabuchi, Y [Dept. of Pediatrics, School of Medicine, Univ. of Tokushima (Japan); Kuroda, Y [Dept. of Pediatrics, School of Medicine, Univ. of Tokushima (Japan)

    1995-06-01

    We present the case of a 6-year-old boy who had an omphalocele repaired at day 1 of life. He had a secundum atrial septal defect and an anomalous inferior vena cava of a type which has not been previously reported. Cine-MRI was a useful noninvasive tool for diagnosing the anomalous subaortic innominate vein and four immature vessels which make up the venous drainage systems of the lumbar region. (orig.)

  3. Anomalous inferior vena cava in association with omphalocele: a case report

    International Nuclear Information System (INIS)

    Antoniou, E.E.H.; Matsuoka, S.; Mori, K.; Hayabuchi, Y.; Kuroda, Y.

    1995-01-01

    We present the case of a 6-year-old boy who had an omphalocele repaired at day 1 of life. He had a secundum atrial septal defect and an anomalous inferior vena cava of a type which has not been previously reported. Cine-MRI was a useful noninvasive tool for diagnosing the anomalous subaortic innominate vein and four immature vessels which make up the venous drainage systems of the lumbar region. (orig.)

  4. Serial repositioning of a Guenther tulip retrievable inferior vena cava filter in a pediatric patient

    International Nuclear Information System (INIS)

    Haider, Ehsan A.; Rosen, J. Choi; Torres, Carlos; Valenti, David A.

    2005-01-01

    We report an 11-year-old boy who required inferior vena cava (IVC) filtration for a prolonged period of time. A retrievable IVC filter was placed and repositioned three times, providing a total of 60 days of IVC filtration. The filter was removed when his risk of pulmonary embolus had decreased substantially. This is a relatively uncommon practice in the pediatric population. The technique is presented, and the available literature is reviewed. (orig.)

  5. [Clinical analysis of patients with lower extremity deep venous thrombosis complicated with inferior vena cava thrombus].

    Science.gov (United States)

    Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing

    2013-06-04

    To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.

  6. Leiomyosarcoma of the inferior vena cava level II involvement: curative resection and reconstruction of renal veins

    Directory of Open Access Journals (Sweden)

    Wang Quan

    2012-06-01

    Full Text Available Abstract Leiomyosarcoma of the inferior vena cava (IVCL is a rare retroperitoneal tumor. We report two cases of level II (middle level, renal veins to hepatic veins IVCL, who underwent en bloc resection with reconstruction of bilateral or left renal venous return using prosthetic grafts. In our cases, IVCL is documented to be occluded preoperatively, therefore, radical resection of tumor and/or right kidney was performed and the distal end of inferior vena cava was resected and without caval reconstruction. None of the patients developed edema or acute renal failure postoperatively. After surgical resection, adjuvant radiation therapy was administrated. The patients have been free of recurrence 2 years and 3 months, 9 months after surgery, respectively, indicating the complete surgical resection and radiotherapy contribute to the better survival. The reconstruction of inferior vena cava was not considered mandatory in level II IVCL, if the retroperitoneal venous collateral pathways have been established. In addition to the curative resection of IVCL, the renal vascular reconstruction minimized the risks of procedure-related acute renal failure, and was more physiologically preferable. This concept was reflected in the treatment of the two patients reported on.

  7. Immediate endovascular treatment of an aortoiliac aneurysm ruptured into the inferior vena cava.

    Science.gov (United States)

    Kopp, Reinhard; Weidenhagen, Rolf; Hoffmann, Ralf; Waggershauser, Tobias; Meimarakis, Georgios; Andrassy, Joachim; Clevert, Dirk; Czerner, Stephan; Jauch, Karl-Walter

    2006-07-01

    An aortocaval fistula is a severe complication of an aortoiliac aneurysm, usually associated with high perioperative morbidity and mortality during open operative repair. We describe the successful endovascular treatment of a symptomatic infrarenal aortic aneurysm ruptured into the inferior vena cava with secondary interventional coiling of a persistent type II endoleak because of retrograde perfusion of the inferior mesenteric artery. Endovascular exclusion of ruptured abdominal aneurysms seems to be a valuable treatment option for selected patients even with complicated vascular conditions like an aortocaval fistula.

  8. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Catherine Yang

    2013-07-01

    Full Text Available Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications.

  9. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yang, Catherine; Trad, Clovis Simao; Trad, Henrique Simao

    2013-01-01

    Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications. (author)

  10. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Catherine; Trad, Clovis Simao [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Trad, Henrique Simao, E-mail: hstrad@terra.com.br [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Universidade de Sao Paulo (HC-FMRPUSP), Ribeirao Preto, SP (Brazil). Fac. de Medicina. Hospital das Clinicas; Mendonca, Silvana Machado [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2013-06-15

    Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications. (author)

  11. Segmental variants of the inferior vena cava - typical findings correlated with embryological development for differential diagnosis; Segmentale Varianten der Vena cava inferior - Erscheinungsbild mit embryologischer Korrelation in Abgrenzung zum sekundaeren Vena-cava-Verschluss

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, D.R. [Abt. fuer Radiologie, Guestrower Krankenhaus, Akademisches Lehrkrankenhaus der Univ. Rostock (Germany); Inst. fuer Radiologie und Nuklearmedizin, Krankenhaus am Urban, Akademisches Lehrkrankenhaus der Freien Univ. Berlin (Germany); Huggle, H.; Hueppe, T.; Friedrich, M. [Inst. fuer Radiologie und Nuklearmedizin, Krankenhaus am Urban, Akademisches Lehrkrankenhaus der Freien Univ. Berlin (Germany); Andresen, R. [Abt. fuer Radiologie, Guestrower Krankenhaus, Akademisches Lehrkrankenhaus der Univ. Rostock (Germany)

    2001-07-01

    The vast variability of the overall rare congenital anomalies of the inferior vena cava (IVC) are mostly detected by accident through different imaging modalities. These cannot be classed as pathological findings, and should not be confused with lymphomas and has to differ from secondary collateral venous pathways. Based on 656 CT examinations 10.5% known forms of IVC anomalies were found. According to the embryological development three main groups of IVC variants could be nosologically classified: agenesis of the suprarenal IVC, anomalies of the pars renalis and anomalies of the infrarenal IVC. Additionally three unusual anomaly complexes were found. For the understanding details of the embryology based on a simplified depiction are presented. (orig.) [German] Die grosse Variabilitaet der als insgesamt selten anzusehenden angeborenen Venenanomalien der Vena cava inferior werden meist zufaellig durch verschiedene bildgebende Untersuchungsverfahren entdeckt. Diese koennen nicht als Pathologien des venoesen Systems klassifiziert werden und sollten nicht mit Lymphomen oder sekundaeren venoesen Kollateralen verwechselt werden. Basierend auf 656 CT-Untersuchungen fanden sich insgesamt 10,5% an bekannten Vena cava inferior (VCI) Anomalien. Unter Beruecksichtigung der embryologischen Entwicklung konnten drei Hauptgruppen an VCI-Varianten nosologisch differenziert werden: Agenesie der suprarenalen VCI, Anomalien der Pars renalis und Anomalien der infrarenalen VCI. Zusaetzlich fanden sich drei ungewoehnliche Anomaliekomplexe. Fuer das Verstaendnis der VCI-Varianten wird eine schematisierte Embryologie praesentiert. (orig.)

  12. Complications after the placement of domestic ZQL filter and imported inferior vena caval filter: a mid-and long-term comparative study

    International Nuclear Information System (INIS)

    Huang Kun; Zhao Yi; Xu Ke; Feng Bo; Liang Songnian

    2009-01-01

    Objective: To investigate the clinical value of domestic ZQL-type inferior vena caval filter through comparing its complications with that of imported inferior vena caval filter. Methods: Domestic ZQL-type inferior vena caval filter was placed in 62 patients (study group) and imported inferior vena caval filter in 58 patients (control group) for the treatment of deep venous thrombosis of the lower limb. Abdominal plain film, lower limb phlebography and/or pulmonary arteriography, color Doppler ultrasonography were performed after the procedure. 3D-CT scanning was carried out when pulmonary embolism was suspected. The complications were documented and analyzed. Results In all patients the inferior vena caval filter was successfully implanted in planned site. In study group, the complications included filter migration over 10 cm (n = 1), thrombus in the filter (n = 1), inferior vena cava obstruction (n = 2) and pulmonary embolism (n = 1). In control group, the complications included thrombus in the filter (n = 2), deep venous thrombus of the lower extremities (n = 2), inferior vena cava obstruction (n = 9), venous perforation by filter (n = 1) and pulmonary embolism (n = 1). The data were compared between two groups and statistic analysis showed no significant difference between two groups (P > 0.05). Conclusion: No significant difference in the occurrence of complications exists between domestic ZQL-type inferior vena caval filter and imported inferior vena caval filter, therefore, domestic ZQL-type inferior vena caval filter can safely substitute for the imported filter. (authors)

  13. Inferior vena cava filters in pulmonary embolism: A historic controversy.

    Science.gov (United States)

    Jerjes-Sanchez, Carlos; Rodriguez, David; Navarrete, Aline; Parra-Cantu, Carolina; Joya-Harrison, Jorge; Vazquez, Eduardo; Ramirez-Rivera, Alicia

    Rationale for non-routine use of inferior venous cava filters (IVCF) in pulmonary embolism (PE) patients. Thrombosis mechanisms involved with IVCF placement and removal, the blood-contacting medical device inducing clotting, and the inorganic polyphosphate in the contact activation pathway were analyzed. In addition, we analyzed clinical evidence from randomized trials, including patients with and without cancer. Furthermore, we estimated the absolute risk reduction (ARR), the relative risk reduction (RRR), and the number needed to treat (NNT) based on the results of each study using a frequency table. Finally, we analyzed the outcome of our PE patients that were submitted to thrombolysis with short and long term follow-up. IVCF induces thrombosis by several mechanisms including placement and removal, rapid protein adsorption, and simultaneous surface-induced activation via the contact activation pathway. Also, inorganic polyphosphate has an important role as a procoagulant, reversing the effect of anticoagulants. Randomized control trials included 904 cancer and non-cancer PE patients. In terms of ARR, RRR, and NNT, there is no evidence for routine use of IVCF. In 290 patients with proved PE, extensive thrombotic burden and right ventricular dysfunction under thrombolysis and oral anticoagulation, we observed a favorable outcome in a short- and long-term follow-up; additionally, IVCF was only used in 5% of these patients. Considering the complex mechanisms of thrombosis related with IVCF, the evidence from randomized control trials and ARR, RRR, and NNT obtained from venous thromboembolism patients with and without cancer, non-routine use of IVCF is recommended. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  14. Intrahepatic venous collaterals forming via the inferior right hepatic vein in 3 patients with obstruction of the inferior vena cava

    International Nuclear Information System (INIS)

    Takayasu, K.; Moriyama, N.; Muramatsu, Y.

    1985-01-01

    When the inferior vena cava is obstructed, collateral veins enlarge, connecting with the inferior (acessory) right hepatic vein (IRHV) and thence through various hepatic veins to the right atrium. Three such cases are described. In one patient, most contrast material flowed into the IRHV and from there to the left hepatic vein. The second patient had several large collaterals arising from the IRHV and flowing into the right and middle hepatic veins, while the third patient demonstrated anastomoses between the IRHV and the middle hepatic vein. All of these hepatic venous shunts eventually drained into the right atrium. There were no clinical manifestations such as ascites, edema, or dilatation of the abdominal veins. Cavography alone or combined with computed tomography proved to be diagnostic in the assessment of these intrahepatic collaterals

  15. Creating a Fontan fenestration in a child with dextrocardia and interrupted inferior vena cava

    Directory of Open Access Journals (Sweden)

    Pradeepkumar Charlagorla

    2016-01-01

    Full Text Available Plastic bronchitis is a rare life-threatening complication of the Fontan operation. Transcatheter Fontan fenestration can ameliorate symptoms by decompressing elevated venous pressures. Transcatheter creation of a fenestration can be technically challenging in cases with complex venous anatomy. We report a case of a 5-year-old boy with heterotaxy, dextrocardia with unbalanced atrioventricular canal (AVC, atrial and visceral situs inversus, left-sided superior vena cava (SVC, and left-sided interrupted inferior vena cava (IVC with azygos continuation. With few modifications to the equipment, a successful Fontan fenestration with stent implantation was performed via transjugular approach. At 2-year follow-up, his symptoms of plastic bronchitis improved significantly.

  16. Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal

    International Nuclear Information System (INIS)

    Abdel-Aal, Ahmed Kamel; Saddekni, Souheil; Hamed, Maysoon Farouk; Fitzpatrick, Farley

    2013-01-01

    Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of an IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.

  17. Endobronchial Forceps-Assisted and Excimer Laser-Assisted Inferior Vena Cava Filter Removal: The Data, Where We Are, and How It Is Done.

    Science.gov (United States)

    Chen, James X; Montgomery, Jennifer; McLennan, Gordon; Stavropoulos, S William

    2018-06-01

    The recognition of inferior vena cava filter related complications has motivated increased attentiveness in clinical follow-up of patients with inferior vena cava filters and has led to development of multiple approaches for retrieving filters that are challenging or impossible to remove using conventional techniques. Endobronchial forceps and excimer lasers are tools for designed to aid in complex inferior vena cava filter removals. This article discusses endobronchial forceps-assisted and excimer laser-assisted inferior vena cava filter retrievals. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Indications, complications and outcomes of elderly patients undergoing retrievable inferior vena cava filter placement.

    Science.gov (United States)

    Rottenstreich, Amihai; Kleinstern, Geffen; Bloom, Allan I; Klimov, Alexander; Kalish, Yosef

    2017-10-01

    The utilization of inferior vena cava filter placement for pulmonary embolism prevention in elderly patients has not been well characterized. The present study aimed to review indications, complications and follow-up data of elderly patients undergoing inferior vena cava filter placement. A retrospective review was carried out of consecutive admitted patients who underwent inferior vena cava filter insertion at a large university hospital with a level I trauma center. Overall, 455 retrievable filters were inserted between 2009 and 2014. A total of 133 patients (29.2%) were aged ≥70 years. Elderly patients were less likely to have their filter retrieved compared with non-elderly patients (5.3% vs 21.4%, P Filter-related complications occurred in 13% of non-elderly patients and 14.3% of elderly patients (P = 0.72), most of them occurring in the first 3 months after filter placement. Survival among elderly patients with no evidence of active malignancy was similar to the non-elderly patients with a 1-year survival rate of 76.3% versus 82% in non-elderly patients (P = 0.22), and a 2-year survival rate of 73.1% versus 78.6% in non-elderly patients (P = 0.27). Although decreased, survival rates among elderly patients with active cancer were still substantial, with a 1-year survival rate of 45% and 2-year survival rate of 40%. Elderly patients had significantly lower rates of filter retrieval with similar complication rate. Survival rates among elderly patients were substantial, and in elderly patients with no active cancer were even comparable with non-elderly patients. When feasible, filter retrieval should be attempted in all elderly patients in order to prevent filter-related complications. Geriatr Gerontol Int 2017; 17: 1508-1514. © 2016 Japan Geriatrics Society.

  19. Percutaneous Transluminal Angioplasty for Complete Membranous Obstruction of Suprahepatic Inferior Vena Cava: Long-Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Kucukay, Fahrettin, E-mail: fkucukay@hotmail.com [Turkiye Yuksek Ihtisas Hospital, Department of Interventional Radiology (Turkey); Akdogan, Meral, E-mail: akdmeral@yahoo.com [Turkiye Yuksek Ihtisas Hospital, Department of Gastroenterology (Turkey); Bostanci, Erdal Birol, E-mail: ebbostanci@yahoo.com [Turkiye Yuksek Ihtisas Hospital, Department of Gastrointestinal Surgery (Turkey); Ulus, Ahmet Tulga, E-mail: uluss@yahoo.com [Hacettepe University, Department of Cardiovascular Surgery (Turkey); Kucukay, Murat Bulent, E-mail: dr-mbk@hotmail.com [Lokman Hekim Hospital, Department of Internal Medicine (Turkey)

    2016-10-15

    PurposeTo determine the long-term results of percutaneous transluminal angioplasty (PTA) for a complete membranous obstruction of the suprahepatic inferior vena cava.MethodsPatients (n = 65) who were referred to the interventional unit for PTA for a complete membranous obstruction of the suprahepatic inferior vena cava between January 2006 and October 2014 were included in the study. Thirty-two patients (18 males, 14 females, mean age 35 ± 10.7, range 20–42 years) were treated. The patients presented with symptoms of ascites (88 %), pleural effusion (53 %), varicose veins (94 %), hepatomegaly (97 %), abdominal pain (84 %), and splenomegaly (40 %). Transjugular liver access set and re-entry catheter were used to puncture and traverse the obstruction from the jugular side. PTA balloon dilations were performed. The mean follow-up period was 65.6 ± 24.5 months. The objective was to evaluate technical success, complications, primary patency, and clinical improvement in the symptoms of the patients.ResultsThe technical success rate was 94 %. In two patients, obstruction could not be traversed. These patients underwent cavoatrial graft bypass surgery. There were no procedure-related complications. Clinical improvements were achieved in all patients within 3 months. The primary patency rate at 4 years was 90 %. There was no primary assisted patency. There was no need for metallic stent deployment in the cohort. The secondary patency rate at 4 years was 100 %.ConclusionsPercutaneous transluminal angioplasty for a complete membranous obstruction of the suprahepatic inferior vena cava is safe and effective, and the long-term results are excellent.

  20. Seminoma Presenting as Renal Mass, Inferior Vena Caval Thrombus, and Regressed Testicular Mass

    Directory of Open Access Journals (Sweden)

    Valary T. Raup

    2015-01-01

    Full Text Available Testicular cancer is the most common malignancy of men aged 15–40. Metastatic spread classically begins with involvement of the retroperitoneal lymph nodes, with metastases to the liver, lung, bone, and brain representing advancing disease. Treatment is based on pathologic analysis of the excised testicle and presence of elevated tumor markers. We report a case of a 34-year-old male presenting with back pain who was found to have a right renal mass with tumor extension into the inferior vena cava. Subsequent biopsy was consistent with seminoma. We review this rare case and discuss the literature regarding its diagnosis and management.

  1. Renal angiomyolipoma with inferior vena caval thrombus in a 32-year-old male

    Directory of Open Access Journals (Sweden)

    Matthew W Christian

    2009-01-01

    Full Text Available Renal angiomyolipoma (AML rarely presents with evidence of extension into the renal vein, inferior vena cava (IVC or atrium. We report a case of a renal AML with a tumor thrombus to the IVC in a 32-year-old male. The patient subsequently underwent a right radical nephrectomy with IVC tumor thrombectomy. To our knowledge, there are four published cases of renal AML presenting with tumor thrombus in males. This case report describes the management of the youngest male ever to develop a renal AML with IVC tumor thrombus.

  2. A fractured inferior vena cava filter strut migrating to the left pulmonary artery

    Directory of Open Access Journals (Sweden)

    Tamer Hudali

    2015-01-01

    Full Text Available Inferior vena cava filters are increasingly used in patients with recurrent venous thromboembolism who are contraindicated to anticoagulation. Migration of a broken strut to the pulmonary artery is a very rare complication of these filters. We report the case of an 83-year-old female who experienced this complication with the migratory strut remaining in the same position for years. This case provides evidence that such filters probably have higher rates of complications than what has been thought that remain asymptomatic. The indications and the management of complications of such devices need to be studied further.

  3. Removal of a Guenther Tulip retrievable inferior vena cava filter after 147 days in a pediatric patient

    Energy Technology Data Exchange (ETDEWEB)

    Mody, Rekha N.; Stokes, LeAnn S.; Bream, Peter R.; Spottswood, Stephanie E. [Vanderbilt University Medical Center, Department of Radiology, Nashville, TN (United States)

    2006-05-15

    A Guenther Tulip retrievable inferior vena cava filter was placed in a 9-year-old boy with T-cell ALL who had both iliofemoral deep vein thrombosis (DVT) and acute intracranial hemorrhage. The filter was removed 147 days after placement, when the patient was no longer at increased risk for DVT or pulmonary embolus. Removal of the filter did not compromise flow through the vena cava. (orig.)

  4. Removal of a Guenther Tulip retrievable inferior vena cava filter after 147 days in a pediatric patient

    International Nuclear Information System (INIS)

    Mody, Rekha N.; Stokes, LeAnn S.; Bream, Peter R.; Spottswood, Stephanie E.

    2006-01-01

    A Guenther Tulip retrievable inferior vena cava filter was placed in a 9-year-old boy with T-cell ALL who had both iliofemoral deep vein thrombosis (DVT) and acute intracranial hemorrhage. The filter was removed 147 days after placement, when the patient was no longer at increased risk for DVT or pulmonary embolus. Removal of the filter did not compromise flow through the vena cava. (orig.)

  5. Interrupted inferior vena cava with hemiazygos continuation in an adult with a persistent left superior vena cava and left single coronary artery: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeo Jin; Kwon, Se Hwan; Ahn, Sung Eun; Kim, Soo Joong; Oh, Joo Hyeong [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Shin, Jong Soo [Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of)

    2016-06-15

    A 50-year-old woman was referred to our institution for medical screening due to an incidental finding on abdominal ultrasonography. She underwent chest, abdomen and cardiac multi-detector computed tomography (MDCT). Her MDCT revealed absence of the hepatic segment of the inferior vena cava (IVC), with hemiazygos continuation and a left single coronary artery. The dilated hemiazygos vein drained directly into the persistent left superior vena cava (SVC). Herein, we reported a very rare case combining an incidentally found interrupted IVC with hemiazygos vein continuation, persistent left SVC and a left single coronary artery diagnosed by MDCT.

  6. Diagnosis of tricuspid insufficiency by Doppler flowmetry in the inferior vena cava. A comparison with right ventricular angiography

    Energy Technology Data Exchange (ETDEWEB)

    Smith, H.J.

    Eighty-five patients subjected to routine heart catheterization were examined with duplex scanning of the inferior vena cava. Adequate Doppler recordings and a right ventricular angiography were obtained in 79 of them. Tricuspid insufficiency was found to be present in 34 patients at angiography and in 24 at duplex examination. No false positive Doppler diagnoses of tricuspid insufficiency occurred. The possibility of false positive angiographic diagnoses is discussed. A high correlation was found between percentage reversed flow in the inferior vena cava during ventricular systole and degree of angiographic tricuspid insufficiency. It is concluded that duplex scanning of the inferior vena cava seems to be a good alternative to angiography in the diagnosis and quantification of tricuspid insufficiency.

  7. The clinical implications of variants of vena cava inferior and aorta on retroperitoneal surgery

    Directory of Open Access Journals (Sweden)

    S. V. Mukhtarulina

    2014-12-01

    Full Text Available Objective: to study variants of retroperitoneal vascular structure and its clinical implications on retroperitoneal surgery in patients with cervical cancer IA–IIB stage.Materials and methods. 101 patients who underwent paraaortic and bilateral pelvic lymphadenectomy were included in this study. 10 patients of the first group with anomalies of inferior vena cava, renal arteries and veins, common iliac vein and ovarian vessels were compared with 91 patients of the second group without anomalies.Results. Variants of major retroperitoneal vascular structure were present in 10 (9.9 % patients. Supernumerary renal arteries and veins observed in 5 (4.9 % patients; retroaortic left renal vein type I and II – in 3 (3.0 % patients. Double vena cava inferior detected in 1 (1.0 % patient. Patients with variants of retroperitoneal vascular structures hadn’t vessel injury. There was no difference in intraoperative hemorrhage, transfusion red blood cell, rate of intraoperative hemoglobin and removed paraaortic lymph nodes between the groups. Risk factors for intraoperative bleeding in patients with cervical cancer, depending on the presence or absence of anomalies of retroperitoneal vessels had no significant difference.Conclusion. Despite the fact that the variants of retroperitoneal vascular structures are rare (9.9 %, the success of retroperitoneal surgery is associated with the knowledge of vascular variations which decrease serious, life-threatening complications.

  8. Is it worth adding an inferior vena cava filter to anticoagulation in thromboembolic disease?

    Directory of Open Access Journals (Sweden)

    Alexandra Yunes

    2017-06-01

    Full Text Available Resumen A pesar del tratamiento anticoagulante, algunos pacientes que han presentado un episodio de enfermedad tromboembólica persisten con riesgo elevado de recurrencia. Se ha planteado que adicionar un filtro de vena cava inferior podría disminuir este riesgo, pero la real utilidad clínica no está clara. Para responder esta pregunta utilizamos la base de datos Epistemonikos, la cual es mantenida mediante búsquedas en múltiples fuentes de información. Identificamos tres revisiones sistemáticas que en conjunto incluyen cuatro ensayos aleatorizados que responden la pregunta. Extrajimos los datos, realizamos un metanálisis y preparamos tablas de resumen de los resultados utilizando el método GRADE. Concluimos que podría existir poca o nula diferencia en cuanto a la ocurrencia de trombosis venosa profunda al agregar un filtro de vena cava inferior en pacientes anticoagulados, y que no está claro si existen diferencias en cuanto a la ocurrencia de tromboembolismo pulmonar o mortalidad porque la certeza de la evidencia es muy baja.

  9. Primary Leiomyosarcoma in the Inferior Vena Cava Extended to the Right Atrium: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Shuichi Fujita

    2016-10-01

    Full Text Available A 38-year-old woman had developed an abdominal distention, lower extremity edema, and dyspnea. Imaging examination revealed a large mass in the right atrium which was connected to lesions within the inferior vena cava. Although complete resection of the mass was not possible, partial surgical tumor resection was performed to avoid pulmonary embolization and circulatory collapse. Leiomyosarcoma was diagnosed histologically, and chemotherapy (doxorubicin followed by radiotherapy was started. By reviewing papers published in the past 10 years that included 322 patients, we also discuss the clinical presentations and prognosis of leiomyosarcoma in the inferior vena cava.

  10. Abdominal wall phlebitis due to Prevotella bivia following renal transplantation in a patient with an occluded inferior vena cava.

    Science.gov (United States)

    Janssen, S; van Donselaar-van der Pant, K A M I; van der Weerd, N C; Develter, W; Bemelman, F J; Grobusch, M P; Idu, M M; Ten Berge, I J M

    2013-02-01

    Pre-existing occlusion of the inferior vena cava may complicate renal transplantation. Suppurative abdominal wall phlebitis following renal transplantation was diagnosed in a patient with pre-existing thrombosis of the inferior vena cava of unknown cause. The phlebitis developed in the subcutaneous collateral veins of the abdominal wall contra-laterally to the renal transplant. Cultures from abdominal wall micro-abscesses yielded Prevotella bivia as the causative agent. This complication has not been described before in the context of renal transplantation. The pathogenesis and management of this serious complication are discussed in this paper.

  11. Left kidney angiomyolipoma, spreading to the renal vein, inferior vena cava and involving the heart. Report of one case

    OpenAIRE

    INNOCENTI C, FRANCO; ALARCÓN C, EMILIO; ARIAS O, ESTEBAN; STOCKINS L, ALECK; SÁNCHEZ U, ROBERTO; MADARIAGA B, JAIME; TORRES-QUEVEDO Q, RODRIGO; CABRERA E, FELIPE; DÍAZ J, RAMÓN

    2008-01-01

    El angiomiolipoma renal es un tumor benigno mesenquimático. Constituyen sólo del 2 al 6% de los tumores renales. Existen alrededor de 12 casos reportados con invasión a las venas renales y la cava inferior. En menos de 5, hay extensión de trombo tumoral hasta aurícula derecha. Objetivo: Presentar el caso clínico, manejo y evolución de una paciente con un angiomiolipoma renal con extensión tumoral a vena renal y cava inferior y que compromete la cavidad auricular derecha casi en su totalidad. ...

  12. Acute iliofemoral venous thrombosis in patients with atresia of the inferior vena cava can be treated successfully with catheter-directed thrombolysis

    DEFF Research Database (Denmark)

    Broholm, Rikke; Jørgensen, Maja; Just, Sven

    2011-01-01

    To assess the effectiveness and clinical outcomes of catheter-directed thrombolysis in patients with atresia of the inferior vena cava (IVC) and acute iliofemoral deep vein thrombosis (DVT).......To assess the effectiveness and clinical outcomes of catheter-directed thrombolysis in patients with atresia of the inferior vena cava (IVC) and acute iliofemoral deep vein thrombosis (DVT)....

  13. Vascular Reconstruction Technique Using a Tubular Graft for Leiomyosarcoma of the Inferior Vena Cava: A Case Report

    Directory of Open Access Journals (Sweden)

    C. Higutchi

    Full Text Available Objective/background: This study is a case report that addresses the key aspects of vascular reconstruction, as well as the intraoperative complications, postoperative morbidity, and possibility of adjunctive therapy. Methods: This article reports the case of a 46 year old female patient with a leiomyosarcoma located in the middle segment of the inferior vena cava (between the renal and hepatic veins who underwent surgical resection with vena cava reconstruction and insertion of a tubular graft made of a synthetic material. Results: This case report reveals that surgical resection of the tumor with the insertion of a smaller-caliber tubular graft provide better patency of the vena cava reconstruction, which was maintained for a year after surgery. In addition, the patient was asymptomatic for lower limb edema, despite having a local recurrence after one year. Surgical resection is the treatment of choice for leiomyosarcoma of the inferior vena cava (LIVC and is the only therapy that offers a chance of cure. Several surgical techniques are used for this condition, especially, reconstruction with a vascular graft using natural or synthetic materials. Conclusion: Due to the aggressiveness of the disease, this study suggests that surgical intervention used may have no influence on a patient's survival outcome. However, vascular reconstruction with a smaller-caliber tubular graft may yield a better prognosis for patients in terms of postoperative symptoms, such as edema and thrombosis. Keywords: Inferior vena cava, Leiomyosarcoma, Synthetic vascular grafting

  14. Cerebral Fat Embolism in a Trauma Patient with Captured Imaging of Echogenic Emboli in the Inferior Vena Cava

    Directory of Open Access Journals (Sweden)

    Nancy N. Wang

    2016-12-01

    Full Text Available The authors present a case of fat embolism syndrome after traumatic long-bone fracture in a patient with rapid neurologic deterioration and multiple cerebral embolic events. Diagnostic workup revealed the neuroradiologic findings classically described with cerebral fat emboli. The authors present hallmark ultrasound imaging of echogenic material actively traveling through the inferior vena cava.

  15. Adult Wilms tumor with inferior vena cava thrombus and distal deep vein thrombosis - a case report and literature review.

    Science.gov (United States)

    Ratajczyk, Krzysztof; Czekaj, Adrian; Rogala, Joanna; Kowal, Pawel

    2018-02-23

    Adult Wilms tumor (WT, nephroblastoma) is a rare, but well-described renal neoplasm. Although inferior vena cava tumor thrombosis is present in up to 10% of Wilms tumors in childhood, only few cases of this clinical manifestation in adults have been reported. To the best of our knowledge, this is the first case of adult WT infiltrating into inferior vena cava (IVC) with concomitant distal deep vein thrombosis. A 28-year-old male patient with gross hematuria and right flank pain was diagnosed with right kidney tumor penetrating to IVC. Preoperatively, acute distal thrombosis in inferior vena cava and lower extremities veins occurred. Right radical nephrectomy with tumor thrombectomy via cavotomy was performed. In order to prevent pulmonary embolism, IVC was ligated below left renal vein level. Histopathological examination revealed a triphasic nephroblastoma without anaplastic features. Postoperatively, patient was diagnosed with metastatic liver disease, which was treated with two lines of chemotherapy followed by radiotherapy with achievement of complete response. Adult WT occurs usually in young patients, under 40 years of age. Neoadjuvant chemotherapy proved to be effective in children, resulting with tumor shrinkage and venous tumor thrombus regression. Therefore, percutaneous biopsy should be always considered in young patients presenting with renal tumor invading venous system. IVC ligation is a safe treatment option in the event of complete inferior vena cava occlusion due to distal thrombosis concomitant to tumor thrombus, provided collateral venous pathways are well-developed.

  16. Changes in inferior vena cava blood flow velocity and diameter during breathing movements in the human fetus

    NARCIS (Netherlands)

    T. Huisman (T.); S. van den Eijnde (Stefan); P.A. Stewart (Patricia); J.W. Wladimiroff (Juriy)

    1993-01-01

    textabstractBreathing movements in the human fetus cause distinct changes in Doppler flow velocity measurements at arterial, venous and cardiac levels. In adults, breathing movements result in a momentary inspiratory collapse of the inferior vena cava vessel wall. The study objective was to quantify

  17. Sequential Venoplasty for Treatment of Inferior Vena Cava Stenosis Following Liver Transplant

    Directory of Open Access Journals (Sweden)

    Ahmad Parvinian

    2014-01-01

    Full Text Available Obstruction of the inferior vena cava (IVC is a rare complication of liver transplantation with significant consequences including intractable ascites and hepatic dysfunction. Although venoplasty and stenting are effective in many cases, patients who fail first-line treatment may require surgical intervention or re-transplantation. Scheduled sequential balloon dilation, an approach frequently used to treat fibrotic, benign biliary strictures, but less commonly vascular lesions, may avert the need for such high-risk alternatives while achieving favorable clinical and angiographic response. Herein, we report the case of a 36-year-old woman with transplant-related, initially angioplasty-resistant IVC stenosis that was successfully treated with sequential balloon dilation.

  18. Brachytherapy for the prevention of neointimal hyperplasia in the canine inferior vena cava after stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Isota, Masayuki; Kaminou, Toshio; Sakai, Yukimasa; Nakamura, Kenji; Yamada, Ryusaku [Osaka City Univ. (Japan). Medical School

    2002-06-01

    The aim of this study was to evaluate the efficacy of brachytherapy for preventing neointimal hyperplasia in the inferior vena cava (IVC) after stent placement. Sixteen beagles underwent Z-stent placement in the IVC and the aorta. For 8 of 16 beagles, irradiation (15 Gy) was delivered endoluminally to the stented segments of each vessel immediately after stent placement using the {sup 192}Ir. All animals were sacrificed after 6 weeks for morphometric and histopathologic examination. Morphometrically, neointimal thickness in the IVC of the radiation group was significantly decreased compared with the control group as well as that in the aorta (p<0.05). Histopathologic findings showed the neointima in the IVC of the control group contained markedly organization of thrombus and neovascularization though that in the IVC of the radiation group consisted mainly of smooth muscle cells without organization of thrombus and neovascularization. From these data intravenous irradiation may prevent clinical restenosis after stent placement. (author)

  19. CT of anomalies of the inferior vena cava and left renal vein

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Oyama, Kazuyuki; Ohtomo, Kuni; Yashiro, Naobumi; Itai, Yuji; Iio, Masahiro; Masuyama, Shigeyoshi.

    1988-01-01

    Incidence of anomalies of the inferior vena cava (IVC) and left renal vein (LRV) was examined with post-contrast abdominal CT studies in the last five years and seven months retrospectively. Of the total 1100 cases, right retrocaval ureter was noted in two cases (0.2 %), left IVC was two (0.2 %) and bilateral IVC was twelve (1.1 %) about anomalies of the IVC. As to anomalies of the LRV, retroaortic LRV was four (0.4 %) and circumaortic LRV was six (0.5 %). These results did not always agree with those of previous reports on dissection cases. Particularly, incidence of anomalies of the LRV on CT was much lower than that on dissection. We speculated that racial difference was one of its causes. Clinical usefulness of CT for evaluation of anomalies of the IVC and LRV was stressed. (author)

  20. Diagnostic imagings and embolotherapy for the superior mesenteric vein-inferior vena cava shunt

    International Nuclear Information System (INIS)

    Morita, Yutaka; Yamada, Masataka; Miyata, Mutsuhiko; Kubo, Kohzo.

    1994-01-01

    Diagnostic imaging and embolization therapy for the uncommon portal and mesenteric vein-inferior vena cave shunt (PV·SMV-IVC shunt) are reported. As the frequency of clinical symptoms such as hematemesis, melena and confusion caused by gastrointestinal varices, or hepatoencephalopathy was about 40%, it was important for this disease entity to be diagnosed with noninvasive diagnostic images. The careful examination of the area around the right renal vein was able to overcome the low diagnostic rate of 20-40% obtained with US and CT images. In cases of simple PV·SMV-IVC shut without gastrointestinal varices, embolization therapy using steel coils and done by the intravenous approach is easy and noninvasive. On the other hand, in cases of complex PV-SMV-IVC shunt with gastrointestinal varices, dual balloon occluded embolization therapy using a liquid sclerosing agent and done by the intravenous and portal approaches is preferable. (author)

  1. Incidental Finding of Inferior Vena Cava Atresia Presenting with Deep Venous Thrombosis following Physical Exertion

    Directory of Open Access Journals (Sweden)

    Shalini Koppisetty

    2015-01-01

    Full Text Available Inferior vena cava atresia (IVCA is a rare but well described vascular anomaly. It is a rare risk factor for deep venous thrombosis (DVT, found in approximately 5% of cases of unprovoked lower extremity (LE DVT in patients <30 years of age. Affected population is in the early thirties, predominantly male, often with a history of major physical exertion and presents with extensive or bilateral DVTs. Patients with IVC anomalies usually develop compensatory circulation through the collateral veins with enlarged azygous/hemizygous veins. Despite the compensatory circulation, the venous drainage of the lower limbs is often insufficient leading to venous stasis and thrombosis. We describe a case of extensive and bilateral deep venous thrombosis following physical exertion in a thirty-six-year-old male patient with incidental finding of IVCA on imaging.

  2. Segmental variants of the inferior vena cava - typical findings correlated with embryological development for differential diagnosis

    International Nuclear Information System (INIS)

    Meyer, D.R.; Huggle, H.; Hueppe, T.; Friedrich, M.; Andresen, R.

    2001-01-01

    The vast variability of the overall rare congenital anomalies of the inferior vena cava (IVC) are mostly detected by accident through different imaging modalities. These cannot be classed as pathological findings, and should not be confused with lymphomas and has to differ from secondary collateral venous pathways. Based on 656 CT examinations 10.5% known forms of IVC anomalies were found. According to the embryological development three main groups of IVC variants could be nosologically classified: agenesis of the suprarenal IVC, anomalies of the pars renalis and anomalies of the infrarenal IVC. Additionally three unusual anomaly complexes were found. For the understanding details of the embryology based on a simplified depiction are presented. (orig.) [de

  3. The Need for Anticoagulation Following Inferior Vena Cava Filter Placement: Systematic Review

    International Nuclear Information System (INIS)

    Ray, Charles E.; Prochazka, Allan

    2008-01-01

    Purpose. To perform a systemic review to determine the effect of anticoagulation on the rates of venous thromboembolism (pulmonary embolus, deep venous thrombosis, inferior vena cava (IVC) filter thrombosis) following placement of an IVC filter. Methods. A comprehensive computerized literature search was performed to identify relevant articles. Data were abstracted by two reviewers. Studies were included if it could be determined whether or not subjects received anticoagulation following filter placement, and if follow-up data were presented. A meta-analysis of patients from all included studies was performed. A total of 14 articles were included in the final analysis, but the data from only nine articles could be used in the meta-analysis; five studies were excluded because they did not present raw data which could be analyzed in the meta-analysis. A total of 1,369 subjects were included in the final meta-analysis. Results. The summary odds ratio for the effect of anticoagulation on venous thromboembolism rates following filter deployment was 0.639 (95% CI 0.351 to 1.159, p = 0.141). There was significant heterogeneity in the results from different studies [Q statistic of 15.95 (p = 0.043)]. Following the meta-analysis, there was a trend toward decreased venous thromboembolism rates in patients with post-filter anticoagulation (12.3% vs. 15.8%), but the result failed to reach statistical significance. Conclusion. Inferior vena cava filters can be placed in patients who cannot receive concomitant anticoagulation without placing them at significantly higher risk of development of venous thromboembolism

  4. Atrophic inferior vena cava is a marker of chronicity of intra-filter and inferior vena cava thrombosis: based on CT findings.

    Science.gov (United States)

    Chen, Liang; Shi, Wanyin; Gu, Jianping; He, Xu; Lou, Wensheng

    2018-04-11

    A permanently indwelling filter in the inferior vena cava (IVC) may induce caval thrombosis, which could develop and evolve from an acute to a chronic phase. The differential diagnosis of acute and chronic thromboses determines the treatment strategy. The role of computed tomography (CT) in diagnosing acute and chronic intra-filter and IVC thromboses has not been well established. This retrospective study summarizes the CT signs that indicate acute and chronic phases of intra-filter and IVC thromboses. This study included eight patients who developed a lower-extremity deep venous thrombosis (DVT) and were treated with intracaval filter placement as an alternative to anticoagulation and thrombolysis. During the follow-up, all patients developed an intra-filter thrombosis in the IVC confirmed by CT and/or CT venography (CTV). Demographic and CT data of all patients during the follow-up period were collected for analysis. All patients had normal-appearing IVCs prior to filter placement, as shown on trans-femoral venography. Eight filters (five TrapEase, three OptEase) were placed in the eight IVCs, respectively. Subsequently, IVC-CT or CTV revealed acute intra-filter or IVC thrombosis in all eight patients, manifesting as an intracaval filling defect and thickened IVC wall. Filter protrusion and secondary caval atrophy seen on CT indicated a chronically occluded IVC. IVC thrombosis may result from filter placement. The chronicity of caval thrombotic occlusion is likely to be associated with filter protrusion and secondary IVC atrophy revealed on CT scans.

  5. [Symmetrical phlebothrombosis of lower extremities resulting from congenital malformation of vena cava inferior].

    Science.gov (United States)

    Halcín, A; Kovácová, E; Mikla, F; Reptová, A; Bedeová, J

    2009-12-01

    Agenesis/atresia ofvena cava inferior is a rare congenital anomaly, caused by an aberrance of embryonal venous system development. This is in most cases asymptomatic, because of well developed collateral venous circulation. However, in some cases, it can be manifested with occurence of deep thrombosis in area of pelvis and lower limbs. In this case report, we repon a 21 year old male with painful swelling of both lower limbs. Ultrasonographic examination revealed a bilateral thrombosis in deep venous system of lower limbs and pelvis. Subsequent CT angiography showed atresia ofinfrarenal segment ofvena cava inferior. According to the CT image thrombotic proces affected also collateral venous system, that joined mostly to vena azygos and hemiazygos. Examination of coagulation system didn't reveal a procuring cause ofthrombotic occurrence. We realized a systemic trombolysis with streptokinase during 5 days. Starting from the fifth day we administered a low molecular weight heparin in anticoagulant dose. This treatment showed a good clinical effect. Pacient was discharged with a long-term oral warfarin therapy in combination with acetylsalicylic acid. In next four months of taking recommended therapy no relapse of thrombotic process nor evolvement of bleeding complication was observed.

  6. Retrievable Inferior Vena Cava Filters: Indications, Indwelling Time, Removal, Success and Complication Rates.

    Science.gov (United States)

    Tashbayev, Alisher; Belenky, Alexander; Litvin, Sergey; Knizhnik, Michael; Bachar, Gil N; Atar, Eli

    2016-02-01

    Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC). To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature. During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complication rates were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature. Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18-99) and was noted to be significantly higher compared to similar studies (53-56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups. In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.

  7. Computational Modeling of Blood Flow in the TrapEase Inferior Vena Cava Filter

    Energy Technology Data Exchange (ETDEWEB)

    Singer, M A; Henshaw, W D; Wang, S L

    2008-02-04

    To evaluate the flow hemodynamics of the TrapEase vena cava filter using three dimensional computational fluid dynamics, including simulated thrombi of multiple shapes, sizes, and trapping positions. The study was performed to identify potential areas of recirculation and stagnation and areas in which trapped thrombi may influence intrafilter thrombosis. Computer models of the TrapEase filter, thrombi (volumes ranging from 0.25mL to 2mL, 3 different shapes), and a 23mm diameter cava were constructed. The hemodynamics of steady-state flow at Reynolds number 600 was examined for the unoccluded and partially occluded filter. Axial velocity contours and wall shear stresses were computed. Flow in the unoccluded TrapEase filter experienced minimal disruption, except near the superior and inferior tips where low velocity flow was observed. For spherical thrombi in the superior trapping position, stagnant and recirculating flow was observed downstream of the thrombus; the volume of stagnant flow and the peak wall shear stress increased monotonically with thrombus volume. For inferiorly trapped spherical thrombi, marked disruption to the flow was observed along the cava wall ipsilateral to the thrombus and in the interior of the filter. Spherically shaped thrombus produced a lower peak wall shear stress than conically shaped thrombus and a larger peak stress than ellipsoidal thrombus. We have designed and constructed a computer model of the flow hemodynamics of the TrapEase IVC filter with varying shapes, sizes, and positions of thrombi. The computer model offers several advantages over in vitro techniques including: improved resolution, ease of evaluating different thrombus sizes and shapes, and easy adaptation for new filter designs and flow parameters. Results from the model also support a previously reported finding from photochromic experiments that suggest the inferior trapping position of the TrapEase IVC filter leads to an intra-filter region of recirculating

  8. Implante de filtro em veia cava inferior dupla: relato de caso e revisão da literatura Filter placement in duplicated inferior vena cava: case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Rafael Demarchi Malgor

    2008-06-01

    Full Text Available Veia cava inferior dupla é uma variação anatômica rara cuja prevalência é de 0,2-3%. O implante de filtro de veia cava, quando indicado em casos com duplicidade da veia cava inferior, pode ser realizado de diferentes formas: em ambas as veias cavas; em uma delas, embolizando a anastomose entre ambas; em somente uma delas; ou por implante supra-renal. Relatamos um caso de trombose venosa profunda no pós-operatório de implante de prótese de quadril com contra-indicação para tratamento anticoagulante e cuja cavografia evidenciou duplicidade de veia cava inferior. O implante de filtro de veia cava inferior realizado em posição supra-renal mostrou-se opção adequada e segura.Double inferior vena cava is a rare anatomic variation with prevalence ranging between 0.2-3.0%. In cases of duplication, inferior vena cava filter placement options include placing it in both vena cava, coil-embolization of the intervenous segment plus placing a filter in the right inferior vena cava, or suprarenal filter placement. We report a case of deep venous thrombosis after unilateral primary total hip replacement, presenting with contraindications for anticoagulant therapy, in which cavography showed inferior vena cava duplication. Inferior vena cava filter placement was performed in the supra-renal portion and was proved to be an adequate and safe procedure.

  9. Infra-renal angles, entry into inferior vena cava and vertebral levels of renal veins.

    Science.gov (United States)

    Satyapal, K S

    1999-10-01

    Current norms for renal vasculature hold true in only half the population. Standard textbooks perpetuate old misconceptions regarding renal venous anatomy. This study is aimed to determine left and right infra-renal angles (L-IRA, R-IRA); entry level of renal veins into the inferior vena cava (IVC), and height of IVC under renal vein influence; and their vertebral level. One hundred morphologically normal en-bloc renal specimens randomly selected from post-mortem examinations were dissected and resin casted. IRA were also measured from venograms of 32 adult and 11 foetal cadavers, as were vertebral entry levels. IRA measurements (degrees) were as follows: left, 55 degrees +/- 16 degrees (20 degrees -102 degrees ); right, 60 degrees +/- 17 degrees (10 degrees -93 degrees ). Left vein entered IVC higher than right 54%, lower 36%, and opposite each other 10%. Vertical distance between lower borders of veins was 1.0 +/- 0.9 cm. Vertical distance of IVC under renal vein influence was 2.3 +/- 1.0 cm. Vertebral level of veins in adults lies between TI2-L2. In foetuses, IRA was as follows: left, 65 degrees +/- 12 degrees (45 degrees -90 degrees ); right, 58 degrees +/- 7 degrees (40 degrees -70 degrees ); vertebral level between T12 and L3. Similar IRA values from literature noted on right, 51 degrees (26 degrees -100 degrees ); differences on left, 77 degrees (43 degrees -94 degrees ), clearly differing from Williams et al. (Gray's Anatomy, 37(th) ed, 1989) statement that renal veins "open into the inferior vena cava almost at right angles." Large variations of IRA are not surprising since kidneys are considered normally "floating viscera," varying position with posture and respiratory movement as well as in live vs. cadaveric subjects. The entry level into the IVC also differs from Williams et al. This study uniquely quantitated actual height difference between lower borders of left and right veins. The data presented appears to be the first documentation of vertebral

  10. Transcatheter closure of patent ductus arteriosus and interruption of inferior vena cava with azygous continuation using an Amplatzer duct occluder II

    Directory of Open Access Journals (Sweden)

    Koh Ghee

    2009-01-01

    Full Text Available We report a case of transcatheter closure of patent ductus arteriosus using the new Amplatzer duct occluder II in an adult patient with interrupted inferior vena cava with azygous continuation via the femoral artery approach.

  11. Posterior Nutcracker Syndrome Associated with Interrupted Left Inferior Vena Cava with Azygos Continuation and Retroaortic Right Renal Vein

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Xiao Li; Zhou, Xiao Dong [Xijing Hospital, Fourth Military Medical University, Shaanxi (China); Qian, Gen Nian; Xiao, Hui; Zhao, Chun Lei [Fuzhou General Hospital, Fujian (China)

    2012-06-15

    Various anatomic anomalies have been considered the causes of nutcracker syndrome (NCS). Posterior NCS refers to the condition, in which vascular narrowing was secondary to the compression of the retroaortic left renal vein while it is crossing between the aorta and the vertebral column. Here, we report an unusual case of posterior NCS associated with a complicated malformation of the interrupted left inferior vena cava with azygos continuation and retroaortic right renal vein, diagnosed by both color Doppler ultrasonography and CT angiography.

  12. Posterior Nutcracker Syndrome Associated with Interrupted Left Inferior Vena Cava with Azygos Continuation and Retroaortic Right Renal Vein

    International Nuclear Information System (INIS)

    Luo, Xiao Li; Zhou, Xiao Dong; Qian, Gen Nian; Xiao, Hui; Zhao, Chun Lei

    2012-01-01

    Various anatomic anomalies have been considered the causes of nutcracker syndrome (NCS). Posterior NCS refers to the condition, in which vascular narrowing was secondary to the compression of the retroaortic left renal vein while it is crossing between the aorta and the vertebral column. Here, we report an unusual case of posterior NCS associated with a complicated malformation of the interrupted left inferior vena cava with azygos continuation and retroaortic right renal vein, diagnosed by both color Doppler ultrasonography and CT angiography.

  13. Fracture and embolization of a Celect inferior vena cava filter strut to the liver: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Hee; Song, Yun Gyu [Dept. of Radiology, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon (Korea, Republic of)

    2017-07-15

    Inferior vena cava (IVC) filters are typically used for prophylaxis against pulmonary embolism. A new version of the Günther Tulip filter, the Celect IVC filter was introduced in April 2007. To the best of our knowledge, there are no reports commenting on Celect IVC filter fracture and fragment embolization to liver. We report a case in which the strut of the Celect IVC filter embolized to the liver.

  14. Percutaneous closure of patent ductus arteriosus via internal jugular vein in patient with interrupted inferior vena cava

    Directory of Open Access Journals (Sweden)

    Patel Nehal

    2009-01-01

    Full Text Available Transcatheter closure of patent ductus arteriosus (PDA using various occluders and coils via femoral vein is a well established therapeutic option. However, in patients with interrupted inferior vena cava (IVC it is not feasible to close the PDA percutaneously using traditional methods. We present a nine-year-old girl with IVC interruption in whom percutaneous closure of PDA was successfully accomplished via the transjugular approach.

  15. [Value of x-ray computed tomography in the study of the inferior vena cava in urologic practice].

    Science.gov (United States)

    Barré, C; Vialle, M; Rieux, D; Caron-Poitreau, C; Soret, J Y; Rognon, M

    1985-01-01

    The CT scan provides a reliable evaluation of the inferior vena cava, especially since the development of second and third generation scanners. It can readily detect congenital malformations and obstructive anomalies complicating renal cancer and it is also able to determine the tumoral or thrombotic nature of the venous obstruction. This excellent definition of the vessel reduces the indications for caval angiography to a few exceptional cases.

  16. Fracture and embolization of a Celect inferior vena cava filter strut to the liver: A Case Report

    International Nuclear Information System (INIS)

    Kim, So Hee; Song, Yun Gyu

    2017-01-01

    Inferior vena cava (IVC) filters are typically used for prophylaxis against pulmonary embolism. A new version of the Günther Tulip filter, the Celect IVC filter was introduced in April 2007. To the best of our knowledge, there are no reports commenting on Celect IVC filter fracture and fragment embolization to liver. We report a case in which the strut of the Celect IVC filter embolized to the liver

  17. Retrieval characteristics of the Bard Denali and Argon Option inferior vena cava filters.

    Science.gov (United States)

    Dowell, Joshua D; Semaan, Dominic; Makary, Mina S; Ryu, John; Khayat, Mamdouh; Pan, Xueliang

    2017-11-01

    The purpose of this study was to compare the retrieval characteristics of the Option Elite (Argon Medical, Plano, Tex) and Denali (Bard, Tempe, Ariz) retrievable inferior vena cava filters (IVCFs), two filters that share a similar conical design. A single-center, retrospective study reviewed all Option and Denali IVCF removals during a 36-month period. Attempted retrievals were classified as advanced if the routine "snare and sheath" technique was initially unsuccessful despite multiple attempts or an alternative endovascular maneuver or access site was used. Patient and filter characteristics were documented. In our study, 63 Option and 45 Denali IVCFs were retrieved, with an average dwell time of 128.73 and 99.3 days, respectively. Significantly higher median fluoroscopy times were experienced in retrieving the Option filter compared with the Denali filter (12.18 vs 6.85 minutes; P = .046). Use of adjunctive techniques was also higher in comparing the Option filter with the Denali filter (19.0% vs 8.7%; P = .079). No significant difference was noted between these groups in regard to gender, age, or history of malignant disease. Option IVCF retrieval procedures required significantly longer retrieval fluoroscopy time compared with Denali IVCFs. Although procedure time was not analyzed in this study, as a surrogate, the increased fluoroscopy time may also have an impact on procedural direct costs and throughput. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  18. Disintegration of the 'waterfall phenomenon' in the inferior vena cava due to right heart failure.

    Science.gov (United States)

    Kira, S; Dambara, T; Mieno, T; Tamaki, S; Natori, H

    1996-03-01

    The concept of the waterfall phenomenon in Zone 2 in the pulmonary vasculature is well known from West's lung model. It is believed that the flow through this zone is determined by the pressure difference between the pulmonary artery and alveoli, and the left atrial pressure is not transmissible to the alveolar capillaries. However, it is impossible to see whether alveolar capillaries are really displaying the waterfall phenomenon or not. In this review, the interrelation between the flow and geometry of the alveolar capillaries in the waterfall phenomenon is analyzed based on physiological studies using a model system and isolated lung lobe experiments. Further, extending the concept to the analysis of ventilatory changes of the inferior vena cava (IVC) configuration, it is ascertained that the waterfall phenomenon normally occurs in the IVC during inspiration just before it enters the thorax and the waterfall phenomenon in the IVC disintegrates with elevation of the central venous pressure. Because these configurations of the IVC in normal and abnormal conditions are visible with ultrasonography, the technique is very useful as a noninvasive approach to diagnose right heart failure.

  19. A case of double inferior vena cava with renal, ovarian and iliac vein variation.

    Science.gov (United States)

    Ito, Taro; Ikeda, Yayoi

    2018-01-01

    We encountered a rare case of an anatomic variant of inferior vena cava (IVC) duplication with renal, ovarian and iliac vein variation in an 81-year-old Japanese female cadaver during a student dissection course of anatomy at Aichi Gakuin University School of Dentistry. The two IVCs ran upwards bilaterally to the abdominal aorta. The left IVC joined with the left renal vein (RV) to form a common trunk that crossed anterior to the aorta and ended at the right IVC. We detected a vein [interiliac vein (IiV)] connecting the two IVCs at the level of the aortic bifurcation. The IiV was formed by the union of two tributaries from the left IVC and a tributary from the left internal iliac vein (IIV) and ran obliquely upwards from left to right. Two right ovarian veins, arising separately from the ipsilateral pampiniform plexus, ran vertically in parallel to each other, and each one independently terminated at the right IVC and the right RV. Two right IIVs, connecting each other with small branches, ascended and separately joined the right external iliac vein. The right and left IIVs were connected to each other. These variations cause abnormal drainage, which could lead to clinical symptoms associated with the dysfunction of the vascular and urogenital systems. Here we describe the detailed anatomical features of the area and discuss the related anatomical and developmental aspects.

  20. Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type

    Science.gov (United States)

    Deso, Steven E.; Idakoji, Ibrahim A.; Kuo, William T.

    2016-01-01

    Many inferior vena cava (IVC) filter types, along with their specific risks and complications, are not recognized. The purpose of this study was to evaluate the various FDA-approved IVC filter types to determine device-specific risks, as a way to help identify patients who may benefit from ongoing follow-up versus prompt filter retrieval. An evidence-based electronic search (FDA Premarket Notification, MEDLINE, FDA MAUDE) was performed to identify all IVC filter types and device-specific complications from 1980 to 2014. Twenty-three IVC filter types (14 retrievable, 9 permanent) were identified. The devices were categorized as follows: conical (n = 14), conical with umbrella (n = 1), conical with cylindrical element (n = 2), biconical with cylindrical element (n = 2), helical (n = 1), spiral (n = 1), and complex (n = 1). Purely conical filters were associated with the highest reported risks of penetration (90–100%). Filters with cylindrical or umbrella elements were associated with the highest reported risk of IVC thrombosis (30–50%). Conical Bard filters were associated with the highest reported risks of fracture (40%). The various FDA-approved IVC filter types were evaluated for device-specific complications based on best current evidence. This information can be used to guide and optimize clinical management in patients with indwelling IVC filters. PMID:27247477

  1. Malignant inferior vena cava obstruction involving right atrium. Palliative treatment with self expandable metallic stent

    International Nuclear Information System (INIS)

    Shao Guoliang; Wang Jianhua; Zhou Kangrong; Yan Zhiping

    2001-01-01

    Objective: To investigate the safety and efficacy of placement of self-expandable metallic stent within right atrium and inferior vena cava (ICV) in patients with malignant ICV obstruction involving right atrium. Methods: There were 5 male patients with advanced hepatocellular carcinoma, aged from 42 to 65 years (mean 56.3 years). The malignancies invaded right atrium and ICV simultaneously, and caused obstruction of ICV. These patients presented symptoms and signs of obstruction of ICV such as hepatomegaly, ascites, edema of lower extremities. 'Z' type stainless steel stents (7.5-10.0 cm in length and 2.5 cm in diameter) were selected for these patients. Part (1.0-3.0 cm in length) of stent was placed in right atrium and the rest was in ICV. Results: All of stents were placed successfully and obstructed ICV reopened. The symptoms of obstruction of ICV relieved or disappeared. There were no recurrence of symptoms of obstruction of ICV and any cardiac complication related to placement of stents in follow-up period (67-188 days). Conclusion: Placement of self-expandable metallic stent within right atrium and ICV in treatment of patients with malignant ICV obstruction involving right atrium is one of the safe and effective methods

  2. Inferior vena cava collapsibility detects fluid responsiveness among spontaneously breathing critically-ill patients.

    Science.gov (United States)

    Corl, Keith A; George, Naomi R; Romanoff, Justin; Levinson, Andrew T; Chheng, Darin B; Merchant, Roland C; Levy, Mitchell M; Napoli, Anthony M

    2017-10-01

    Measurement of inferior vena cava collapsibility (cIVC) by point-of-care ultrasound (POCUS) has been proposed as a viable, non-invasive means of assessing fluid responsiveness. We aimed to determine the ability of cIVC to identify patients who will respond to additional intravenous fluid (IVF) administration among spontaneously breathing critically-ill patients. Prospective observational trial of spontaneously breathing critically-ill patients. cIVC was obtained 3cm caudal from the right atrium and IVC junction using POCUS. Fluid responsiveness was defined as a≥10% increase in cardiac index following a 500ml IVF bolus; measured using bioreactance (NICOM™, Cheetah Medical). cIVC was compared with fluid responsiveness and a cIVC optimal value was identified. Of the 124 participants, 49% were fluid responders. cIVC was able to detect fluid responsiveness: AUC=0.84 [0.76, 0.91]. The optimum cutoff point for cIVC was identified as 25% (LR+ 4.56 [2.72, 7.66], LR- 0.16 [0.08, 0.31]). A cIVC of 25% produced a lower misclassification rate (16.1%) for determining fluid responsiveness than the previous suggested cutoff values of 40% (34.7%). IVC collapsibility, as measured by POCUS, performs well in distinguishing fluid responders from non-responders, and may be used to guide IVF resuscitation among spontaneously breathing critically-ill patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Leiomyosarcomas of the inferior vena cava: diagnostic features on cross-sectional imaging

    International Nuclear Information System (INIS)

    Ganeshalingam, S.; Rajeswaran, G.; Jones, R.L.; Thway, K.; Moskovic, E.

    2011-01-01

    Aim: To evaluate the cross-sectional radiological appearances and to review the clinical presentation and outcome of patients with leiomyosarcomas of the inferior vena cava (IVC LMS). These are rare aggressive tumours that present late with non-specific symptoms and have a poor prognosis. Materials and Methods: From January 2002 to December 2008, the radiological images of 23 sequential patients with pathologically proven IVC LMS were independently reviewed by two experienced radiologists. The clinical presentation, treatment including surgical details, and outcome were recorded. Results: There were 19 females and four males with a mean age of 53 years. CT typically demonstrated a large, lobulate, non-calcified heterogeneous mass with peripheral enhancement. T1-weighted magnetic resonance imaging (MRI) images demonstrated a mass with a low signal intensity and T2-weighted MRI images demonstrated a mass with a high signal intensity. Clinical presentation included leg oedema, back and abdominal pain with almost 50% of patients presenting with metastases. Eleven patients underwent ablative surgery. The mean survival time of all patients in the study was 34 months and that of the 11 post-surgical patients was 56 months. Conclusion: There are a variety of diagnostic features on both computed tomography (CT) and MRI which aid the diagnosis of this unusual vascular neoplasm. CT is vital in determining the location of the tumour within the IVC and MRI accurately depicts its extent and the potential for surgical resectability, which offers the only chance of survival.

  4. Pelvic Venous Variations in Patients with Congenital Inferior Vena Cava Anomalies: Classification with Computed Tomography

    International Nuclear Information System (INIS)

    Morita, S.; Higuchi, M.; Saito, N.; Mitsuhashi, N.

    2007-01-01

    Background: Pelvic venous variations of congenital inferior vena cava (IVC) anomalies that have the potential to cause problems during related surgery and interventional radiology are not fully appreciated. Purpose: To classify pelvic venous variations of congenital IVC anomalies using computed tomography (CT). Material and Methods: CT images for 36 patients with congenital IVC anomalies were retrospectively reviewed. Pelvic venous variations were classified with regard to the relationship with the iliac veins and the presence of interiliac communication. Results: Pelvic venous variations were classified into eight types. One azygous continuation displayed normal connection with the bilateral common iliac veins (CIV) (type 1). Of 28 double IVCs, 11 (39.3%) displayed no interiliac communication (type 2a), five (17.9%) displayed interiliac communication from the left CIV (type 2b), one (3.6%) had communication from the right CIV (type 2c), six (21.4%) had communication from the left internal iliac vein (IIV) (type 2d), and five (17.9%) had communication from the right IIV (type 2e). Six left IVCs displayed symmetrical-to-normal connection with the bilateral CIV (type 3). One absence of infrarenal IVC displayed no connection with the CIV (type 4). Conclusion: Eight types of pelvic venous variations of congenital IVC anomalies were classified using CT

  5. Leiomyosarcomas of the inferior vena cava: diagnostic features on cross-sectional imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ganeshalingam, S., E-mail: skandadas.ganeshalingam@nhs.ne [Department of Clinical Radiology, The Royal Marsden NHS Foundation Trust, London (United Kingdom); Rajeswaran, G. [Department of Clinical Radiology, The Royal Marsden NHS Foundation Trust, London (United Kingdom); Jones, R.L. [Department of Clinical Oncology, University of Washington and Hutchinson Cancer Research Center, Seattle, WA (United States); Thway, K. [Department of Histopathology, The Royal Marsden NHS Foundation Trust, London (United Kingdom); Moskovic, E. [Department of Clinical Radiology, The Royal Marsden NHS Foundation Trust, London (United Kingdom)

    2011-01-15

    Aim: To evaluate the cross-sectional radiological appearances and to review the clinical presentation and outcome of patients with leiomyosarcomas of the inferior vena cava (IVC LMS). These are rare aggressive tumours that present late with non-specific symptoms and have a poor prognosis. Materials and Methods: From January 2002 to December 2008, the radiological images of 23 sequential patients with pathologically proven IVC LMS were independently reviewed by two experienced radiologists. The clinical presentation, treatment including surgical details, and outcome were recorded. Results: There were 19 females and four males with a mean age of 53 years. CT typically demonstrated a large, lobulate, non-calcified heterogeneous mass with peripheral enhancement. T1-weighted magnetic resonance imaging (MRI) images demonstrated a mass with a low signal intensity and T2-weighted MRI images demonstrated a mass with a high signal intensity. Clinical presentation included leg oedema, back and abdominal pain with almost 50% of patients presenting with metastases. Eleven patients underwent ablative surgery. The mean survival time of all patients in the study was 34 months and that of the 11 post-surgical patients was 56 months. Conclusion: There are a variety of diagnostic features on both computed tomography (CT) and MRI which aid the diagnosis of this unusual vascular neoplasm. CT is vital in determining the location of the tumour within the IVC and MRI accurately depicts its extent and the potential for surgical resectability, which offers the only chance of survival.

  6. Bird's nest versus the Kimray-Greenfield inferior vena cava filter: Randomized clinical study

    International Nuclear Information System (INIS)

    Athanasoulis, C.A.; Roberts, A.C.; Brown, K.; Geller, S.C.; Waltman, A.C.; Eckstein, M.R.

    1987-01-01

    A randomized clinical study was conducted comparing the percutaneously introduced bird's nest inferior vena cava (IVC) filter and the Kimray-Greenfield IVC filter. Study end points included recurrent pulmonary embolism, new or worse leg venous stasis symptoms, IVC thrombosis, and ease of filter introduction. Of the 109 patients in the study, 58 were randomly assigned to the BN and 51 to the KG filter. Demographic factors were comparable between the two groups. Follow-up entailed cavography, noninvasive assessment of the femoral veins, and standardized telephone interviews. The follow-up period was extended to 1 year after filter insertion. Results for the bird's nest versus the Kimray-Greenfield filter respectively were as follows: death due to massive pulmonary embolism, 3% versus 5%; recurrent pulmonary embolism, 1.5% versus 7.5%; filter migration, 1.1% versus 0.0%; IVC thrombosis, 6% versus 2.5%; new or worse leg edema, 28.5% versus 22%; ease of introduction (qualitative), maximal versus minimal; patient discomfort (qualitative), minimal versus maximal. The authors conclude the bird's nest filter is better than the Kimray-Greenfield filter in terms of prevention of recurrent pulmonary embolism and ease of introduction. In terms of venous stasis, the bird's nest filter is not better and may be worse than the Kimray-Greenfield filter. Filter migration is a problem with the bird's nest filter

  7. Cardiac variation of inferior vena cava: new concept in the evaluation of intravascular blood volume.

    Science.gov (United States)

    Nakamura, Kensuke; Tomida, Makoto; Ando, Takehiro; Sen, Kon; Inokuchi, Ryota; Kobayashi, Etsuko; Nakajima, Susumu; Sakuma, Ichiro; Yahagi, Naoki

    2013-07-01

    Evaluation of the intravascular blood volume is an important assessment in emergency and critical care medicine. Measurement of the inferior vena cava (IVC) respiratory variation by ultrasound echography is useful, but it entails subjective problems. We have hypothesized that IVC cardiac variation is also correlated with intravascular blood volume and analyzed it automatically using computer software of two kinds, later comparing the results. Snakes, software to track boundaries by curve line continuity, and template matching software were incorporated into a computer with an ultrasound machine to track the short-axis view of IVC automatically and analyze it with approximation by ellipse. Eight healthy volunteers with temporary mild hypovolemia underwent echography before and after passive leg raising and while wearing medical anti-shock trousers. IVC cardiac variation was visually decreased by both leg raising and medical anti-shock trousers. The collapse index (maximum - minimum/maximum) of area during three cardiac beats was decreased showing a good relationship to fluid load simulations; 0.24 ± 0.03 at baseline versus 0.11 ± 0.01 with leg raising and 0.12 ± 0.01 with medical anti-shock trousers. In conclusion, IVC cardiac variation has the potential to provide an evaluation of water volume. It presents some advantages in mechanical analysis over respiratory variation. At the very least, we need to exercise some caution with cardiac variation when evaluating respiratory variation.

  8. The Guenther temporary inferior vena cava filter for short-term protection against pulmonary embolism

    International Nuclear Information System (INIS)

    Vos, Louwerens D.; Tielbeek, Alexander V.; Bom, Ernst P.; Gooszen, Harm C.; Vroegindeweij, Dammis

    1997-01-01

    Purpose. To evaluate clinically the Guenther temporary inferior vena cava (IVC) filter. Methods. Eleven IVC filters were placed in 10 patients. Indications for filter placement were surgical pulmonary embolectomy in seven patients, pulmonary embolism in two patients, and free-floating iliofemoral thrombus in one patient. Eight filters were inserted from the right femoral approach, three filters from the left. Follow-up was by plain abdominal radiographs, cavography, and duplex ultrasound (US). Eight patients received systemic heparinization. Follow-up, during 4-60 months after filter removal was by clinical assessment, and imaging of the lungs was performed when pulmonary embolism (PE) was suspected. Patients received anticoagulation therapy for at least 6 months. Results. Ten filters were removed without complications 7-14 days (mean 10 days) after placement. One restless patient pulled the filter back into the common femoral vein, and a permanent filter was placed. In two patients a permanent filter was placed prior to removal. One patient developed sepsis, and one an infection at the insertion site. Clinically no recurrent PE developed with the filter in place or during removal. One patient had recurrent PE 7 months after filter removal. Conclusion. The Guenther temporary IVC filter can be safely placed for short-term protection against PE. The use of this filter is not appropriate in agitated or immunocompromised patients

  9. Left-sided and duplicate inferior vena cava: a case series and review.

    Science.gov (United States)

    Ang, Wee Choen; Doyle, Terry; Stringer, Mark D

    2013-11-01

    Left-sided and duplicate inferior vena cava (IVC) are two major anatomical variants within the spectrum of IVC malformations, both of which are developmental abnormalities of the supracardinal veins. Four clinical cases are described to highlight the computed tomographic appearances of these vascular malformations and provide novel data on venous dimensions. A systematic review of the recent literature (2000-2011) was conducted focusing on the anatomy, demographics, and associated pathology (congenital and acquired) of isolated left-sided and duplicate IVC. A total of 73 relevant articles were retrieved, consisting of case reports and small case series. The prevalence of left-sided IVC is about 0.1-0.4% and that for duplicate IVC about 0.3-0.4%; both anomalies show a slight male preponderance. In each condition, there are documented variations in the course and tributaries of the IVC. The clinical importance of these anomalies lies in three principal areas: the potential for misdiagnosis on imaging; technical difficulties during retroperitoneal surgery (particularly abdominal aortic aneurysm repair and live donor nephrectomy); and their significance in relation to the etiology and management of venous thromboembolism. Copyright © 2012 Wiley Periodicals, Inc.

  10. Clinical review: inferior vena cava filters in the age of patient-centered outcomes.

    Science.gov (United States)

    Wang, Stephen L; Lloyd, Allen J

    2013-11-01

    Inferior vena cava filter (IVCF) use continues to increase in the United States (US) despite questionable clinical benefit and increasing concerns over long-term complications. For this review we comprehensively examine the randomized, prospective data on IVC filter efficacy, compare relative rates of IVCF placement in the US and Europe, compare commonly considered guidelines for IVCF indications, and the current data on IVCF complications. Searches of MEDLINE and Cochrane databases were conducted for randomized prospective IVCF studies. Only three randomized prospective studies for IVCFs were identified. Commonly cited IVCF guidelines were reviewed with attention to their evolution over time. No evidence has shown a survival benefit with IVCF use. Despite this, continued rising utilization, especially for primary prophylactic indications, is concerning, given increasing evidence of long-term filter-related complications. This is particularly noted in the US where IVCF placements for 2012 are projected to be 25 times that of an equivalent population in Europe (224,700 versus 9,070). Pending much-needed randomized controlled trials that also evaluate long-term safety, we support the more stringent American College of Chest Physicians (ACCP) guidelines for IVCF placement indications and advocate a close, structured follow-up of retrievable IVCFs to improve filter retrieval rates.

  11. Assessment of Snared-Loop Technique When Standard Retrieval of Inferior Vena Cava Filters Fails

    International Nuclear Information System (INIS)

    Doody, Orla; Noe, Geertje; Given, Mark F.; Foley, Peter T.; Lyon, Stuart M.

    2009-01-01

    Purpose To identify the success and complications related to a variant technique used to retrieve inferior vena cava filters when simple snare approach has failed. Methods A retrospective review of all Cook Guenther Tulip filters and Cook Celect filters retrieved between July 2006 and February 2008 was performed. During this period, 130 filter retrievals were attempted. In 33 cases, the standard retrieval technique failed. Retrieval was subsequently attempted with our modified retrieval technique. Results The retrieval was successful in 23 cases (mean dwell time, 171.84 days; range, 5-505 days) and unsuccessful in 10 cases (mean dwell time, 162.2 days; range, 94-360 days). Our filter retrievability rates increased from 74.6% with the standard retrieval method to 92.3% when the snared-loop technique was used. Unsuccessful retrieval was due to significant endothelialization (n = 9) and caval penetration by the filter (n = 1). A single complication occurred in the group, in a patient developing pulmonary emboli after attempted retrieval. Conclusion The technique we describe increased the retrievability of the two filters studied. Hook endothelialization is the main factor resulting in failed retrieval and continues to be a limitation with these filters.

  12. Adrenocortical carcinoma with extension to the inferior vena cava and right atrium: 20-month-old girl with TP53 mutation

    Directory of Open Access Journals (Sweden)

    Terry L. Levin, MD

    2015-01-01

    Full Text Available A 20-month-old female presented with respiratory distress and a right adrenal mass extending into the inferior vena cava and right atrium. The mass was initially thought to be neuroblastoma. Pathology later revealed adrenocortical carcinoma. Inferior vena cava extension is far more common in adrenocortical carcinoma than neuroblastoma, and its presence should prompt clinical and laboratory evaluation for an adrenocortical tumor. The genetic findings in TP53 associated with this disease are discussed.

  13. Transient right-sided heart failure after percutaneous transluminal angioplasty (PTA) of Membranous obstruction of inferior vena cava: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Bin [College of Medicine, University of Ulsan, Ulsan (Korea, Republic of); Lee, Deok hee; Kim, Yeon Suk; Jung, Seung Mun; Ryu, Dae Sik; Park, Man Soo [Kangnung Hospital, Kangnung (Korea, Republic of)

    2000-09-01

    We experienced a case of transient right-sided heart failure after angioplasty of membranous obstruction of the inferior vena cava confirmed by sonography and an inferior vena cavogram. Angioplasty involved the use of a self-expandable metallic stent, but after successful recanalization of the obstruction, the patient became dyspneic. Chest radiography revealed mild cardiomegaly with pulmonary congestion, but this was resolved spontaneously. For the prevention of serious heart failure, we recommend preprocedural evaluation of cardiac function. (author)

  14. Experimental evaluation of a new retrievable inferior vena cava filter for protection from acute pulmonary embolism in canine

    International Nuclear Information System (INIS)

    Zhou Chungao; Shi Haibing; Liu Sheng; Wang Chenghu; Liu Hairi; Li Linsun

    2007-01-01

    Objective: To evaluate the validity, safety and feasibility of a new retrieval inferior vena cava filter for the prevention of pulmonary embolism in an animal model. Methods: The model of deep iliofemoral venous thrombosis was established in 12 experimental dogs. In control group(6 experimental dogs), the deep venous thrombosis was made to fall off directly. In experimental group (6 experimental dogs), the deep venous thrombosis was made to fall off with an implanted filter in inferior vena cava. The filter's thrombus-trapping efficacy was evaluated by angiography of pulmonary artery, measurement of the mean pressure of pulmonary artery and arterial oxygen saturation before and after the deep venous thrombus falling off. Results: All filters implanted in the experimental dogs could successfully capture clot coming from deep venous thrombosis. There was no case of pulmonary embolism in experimental groups. On the other hand, pulmonary embolism occurred following the fall of deep venous thrombus in all dogs of control group. Conclusion: The retrievable inferior vena cava filter can effectively prevent from the pulmonary embolism due to falling off of the emboli from deep venous thrombosis. The process of implantation and retrieval is relatively simple and easy. (authors)

  15. Pseudo interruption of the inferior vena cava complicating the device closure of patent ductus arteriosus: Case report and short review of venous system embryology

    Directory of Open Access Journals (Sweden)

    Venkateshwaran Subramanian

    2014-01-01

    Full Text Available A nineteen-month-old girl was taken up for patent ductus arteriosus (PDA device closure. A diagnostic catheter from the right femoral venous access entered the superior vena cava (SVC, through the azygos vein suggesting interruption of inferior vena caval with azygos continuity. Therefore, the PDA device was closed from the right jugular venous access. However, a postprocedure echocardiogram (echo showed a patent inferior vena caval connection into the right atrium. An angiogram from femoral veins showed communication between the iliac veins and the azygos system, in addition to normal drainage into the inferior vena cava (IVC. Congenital communication between the iliac veins and the azygos system can mimic IVC interruption. An attempt to theoretically explain the embryological origin of the communication has been made.

  16. Denali, Tulip, and Option Inferior Vena Cava Filter Retrieval: A Single Center Experience.

    Science.gov (United States)

    Ramaswamy, Raja S; Jun, Emily; van Beek, Darren; Mani, Naganathan; Salter, Amber; Kim, Seung K; Akinwande, Olaguoke

    2018-04-01

    To compare the technical success of filter retrieval in Denali, Tulip, and Option inferior vena cava filters. A retrospective analysis of Denali, Gunther Tulip, and Option IVC filters was conducted. Retrieval failure rates, fluoroscopy time, sedation time, use of advanced retrieval techniques, and filter-related complications that led to retrieval failure were recorded. There were 107 Denali, 43 Option, and 39 Tulip filters deployed and removed with average dwell times of 93.5, 86.0, and 131 days, respectively. Retrieval failure rates were 0.9% for Denali, 11.6% for Option, and 5.1% for Tulip filters (Denali vs. Option p = 0.018; Denali vs. Tulip p = 0.159; Tulip vs. Option p = 0.045). Median fluoroscopy time for filter retrieval was 3.2 min for the Denali filter, 6.75 min for the Option filter, and 4.95 min for the Tulip filter (Denali vs. Option p Option p = 0.67). Advanced retrieval techniques were used in 0.9% of Denali filters, 21.1% in Option filters, and 10.8% in Tulip filters (Denali vs. Option p Option p Option filter when compared to both the Denali and Tulip filters. Retrieval of the Denali filter required significantly less amount of fluoroscopy time and use of advanced retrieval techniques when compared to both the Option and Tulip filters. The findings of this study indicate easier retrieval of the Denali and Tulip IVC filters when compared to the Option filter.

  17. Occult Amebic Liver Abscess as Cause of Extensive Inferior Vena Cava and Hepatic Vein Thrombosis.

    Science.gov (United States)

    Martin, Leslie; Burute, Nishigandha; Haider, Ehsan; Serrano, Pablo E; O'Shea, Timothy; Siegal, Deborah

    2017-10-01

    The most common extraintestinal complication of Entamoeba histolytica is amebic liver abscess (ALA). Hepatic vein and inferior vena cava (IVC) thrombosis are rare but well-documented complications of ALA, typically attributed to mechanical compression and inflammation associated with a large abscess. We present a case of a previously healthy 43-year-old Canadian man presenting with constitutional symptoms and right upper quadrant abdominal pain. He was found to have thrombophlebitis of the IVC, accessory right hepatic vein, and bilateral iliac veins. Extensive investigations for thrombophilia were negative. Magnetic resonance imaging of the liver demonstrated a 3.2-cm focal area of parenchymal abnormality that was reported as presumptive hepatocellular carcinoma, and a 1.9-cm lesion in the caudate lobe with diffusion restriction and peripheral rim enhancement. Despite multiple biopsy attempts, a histopathological diagnosis was not achieved. Abdominal pain and fever 4 months later prompted repeat ultrasound demonstrating a 10.4- × 12.0-cm rim-enhancing fluid attenuation lesion felt to represent a liver abscess. Thick dark "chocolate brown" drainage from the lesion and positive serology for E. histolytica confirmed the diagnosis of ALA acquired from a previous trip to Cuba. The patient was started on treatment with metronidazole and paromomycin and repeat abdominal ultrasound demonstrated resolution of the abscess. This case is the first to demonstrate extensive IVC thrombosis secondary to a relatively small occult ALA and emphasizes the thrombogenic potential of ALA. Amebic infection should be considered as a rare cause of IVC thrombosis in the correct clinical context.

  18. Gunther Tulip Retrievable Inferior Vena Caval Filters: Indications, Efficacy, Retrieval, and Complications

    International Nuclear Information System (INIS)

    Looby, S.; Given, M.F.; Geoghegan, T.; McErlean, A.; Lee, M.J.

    2007-01-01

    Purpose. We evaluated the Gunther Tulip (GT) retrievable inferior vena cava (IVC) filter with regard to indications, filtration efficacy, complications, retrieval window, and use of anticoagulation. Method. A retrospective study was performed of 147 patients (64 men, 83 women; mean age 58.8 years) who underwent retrievable GT filter insertion between 2001 and 2005. The indications for placement included a diagnosis of pulmonary embolism or deep venous thrombosis with a contraindication to anticoagulation (n = 68), pulmonary embolism or deep venous thrombosis while on anticoagulation (n = 49), prophylactic filter placement for high-risk surgical patients with a past history of pulmonary embolism or deep venous thrombosis (n = 20), and a high risk of pulmonary embolism or deep venous thrombosis (n = 10). Forty-nine of the 147 patients did not receive anticoagulation (33.7%) while 96 of 147 patients did, 82 of these receiving warfarin (56.5%), 11 receiving low-molecular weight heparins (7.58%), and 3 receiving antiplatelet agents alone (2.06%). Results. Filter placement was successful in 147 patients (100%). Two patients had two filters inserted. Of the 147 patients, filter deployment was on a permanent basis in 102 and with an intention to retrieve in 45 patients. There were 36 (80%) successful retrievals and 9 (20%) failed retrievals. The mean time to retrieval was 33.6 days. The reasons for failed retrieval included filter struts tightly adherent to the IVC wall (5/9), extreme filter tilt (2/9), and extensive filter thrombus (2/9). Complications included pneumothorax (n = 4), failure of filter expansion (n = 1), and breakthrough pulmonary embolism (n = 1). No IVC thrombotic episodes were recorded. Discussion. The Gunther Tulip retrievable filter can be used as a permanent or a retrievable filter. It is safe and efficacious. GT filters can be safely retrieved at a mean time interval of 33.6 days. The newly developed Celect filter may extend the retrieval interval

  19. Differences in radial expansion force among inferior vena cava filter models support documented perforation rates.

    Science.gov (United States)

    Robins, J Eli; Ragai, Ihab; Yamaguchi, Dean J

    2018-05-01

    Inferior vena cava (IVC) filters are used in patients at risk for pulmonary embolism who cannot be anticoagulated. Unfortunately, these filters are not without risk, and complications include perforation, migration, and filter fracture. The most prevalent complication is filter perforation of the IVC, with incidence varying among filter models. To our knowledge, the mechanical properties of IVC filters have not been evaluated and are not readily available through the manufacturer. This study sought to determine whether differences in mechanical properties are similar to differences in documented perforation rates. The radial expansion forces of Greenfield (Boston Scientific, Marlborough, Mass), Cook Celect (Cook Medical, Bloomington, Ind), and Cook Platinum filters were analyzed with three replicates per group. The intrinsic force exerted by the filter on the measuring device was collected in real time during controlled expansion. Replicates were averaged and significance was determined by calculating analysis of covariance using SAS software (SAS Institute, Cary, NC). Each filter model generated a significantly different radial expansion force (P filter, followed by the Cook Celect and Greenfield filters. Radial force dispersion during expansion was greatest in the Cook Celect, followed by the Cook Platinum and Greenfield filters. Differences in radial expansion forces among IVC filter models are consistent with documented perforation rates. Cook Celect IVC filters have a higher incidence of perforation compared with Greenfield filters when they are left in place for >90 days. Evaluation of Cook Celect filters yielded a significantly higher radial expansion force at minimum caval diameter, with greater force dispersion during expansion. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  20. Retrospective analysis of outcomes following inferior vena cava (IVC) filter placement in a managed care population.

    Science.gov (United States)

    Everhart, Damian; Vaccaro, Jamieson; Worley, Karen; Rogstad, Teresa L; Seleznick, Mitchel

    2017-08-01

    The role of inferior vena cava filter (IVC) filters for prevention of pulmonary embolism (PE) is controversial. This study evaluated outcomes of IVC filter placement in a managed care population. This retrospective cohort study evaluated data for individuals with Humana healthcare coverage 2013-2014. The study population included 435 recipients of prophylactic IVC filters, 4376 recipients of therapeutic filters, and two control groups, each matched to filter recipients. Patients were followed for up to 2 years. Post-index anticoagulant use, mortality, filter removal, device-related complications, and all-cause utilization. Adjusted regression analyses showed a positive association between filter placement and anticoagulant use at 3 months: odds ratio (ORs) 3.403 (95% CI 1.912-6.059), prophylactic; OR, 1.356 (95% CI 1.164-1.58), therapeutic. Filters were removed in 15.67% of prophylactic and 5.69% of therapeutic filter cases. Complication rates were higher with prophylactic procedures than with therapeutic procedures and typically exceeded 2% in the prophylactic group. Each form of filter placement was associated with increases in all-cause hospitalization (regression coefficient 0.295 [95% CI 0.093-0.498], prophylactic; 0.673 [95% CI 0.547-0.798], therapeutic) and readmissions (OR 2.444 [95% CI 1.298-4.602], prophylactic; 2.074 [95% CI 1.644-2.616], therapeutic). IVC filter placement in this managed care population was associated with increased use of anticoagulants and greater healthcare utilization compared to controls, low rates of retrieval, and notable rates of device-related complications, with effects especially pronounced in assessments of prophylactic filters. These findings underscore the need for appropriate use of IVC filters.

  1. Inferior Vena Cava Filter Limb Fracture with Embolization to the Right Ventricle.

    Science.gov (United States)

    Jackson, Bradley S; Sepula, Mykel; Marx, Jared T; Cannon, Chad M

    2017-08-01

    Inferior vena cava (IVC) filter and filter limb embolization is a known phenomenon, with a prevalence of up to 25% for certain filter types. Most commonly, the site of embolization is to the heart. Point-of-care ultrasound is an easily accessible imaging modality that should be utilized when considering IVC filter complications. A 28-year-old woman with a history of metastatic sarcoma and IVC filter placement for deep venous thrombosis presented to the Emergency Department (ED) for chest pain. Chest radiography was reviewed and originally thought to have no abnormalities. Chest computed tomography angiography was negative for filling defects or foreign bodies. A possible foreign body in the heart was noted by a radiologist's over-read of the original chest radiograph. An echocardiogram done by Cardiology was negative for foreign bodies or other abnormalities. Next, an emergency physician performed a bedside echocardiogram, with focused attention to the right side of the heart. An echogenic foreign body was visualized in the right ventricle. The patient was subsequently taken to the cardiac catheterization laboratory, where fluoroscopic visualization of a limb wire of an IVC filter within the right ventricle was obtained. That foreign body was subsequently removed successfully, along with removal of the broken IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case report highlights the utility of point-of-care ultrasound in the work-up of a patient with an embolized IVC filter wire. Chest pain patients frequently receive point-of-care echocardiography in the ED, and these ultrasound findings should be recognized and used to guide further treatment and consultation. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Inferior Vena Cava Filter Placement and Retrieval Rates among Radiologists and Nonradiologists.

    Science.gov (United States)

    Guez, David; Hansberry, David R; Eschelman, David J; Gonsalves, Carin F; Parker, Laurence; Rao, Vijay M; Levin, David C

    2018-04-01

    To evaluate inferior vena cava (IVC) filter placement and retrieval rates among radiologists, vascular surgeons, cardiologists, other surgeons, and all other health care providers for Medicare fee-for-service beneficiaries in the years 2012-2015. The nationwide Medicare Physician/Supplier Procedure Summary Master Files were used to determine the volume and utilization rate of IVC filter placement, IVC filter repositioning, and IVC filter retrieval, which correspond to procedure codes 37191, 37192, and 37193, respectively. Procedural code 37193 was not available before 2012, so data were reviewed for the years 2012-2015. The total volume of Medicare IVC filter placement decreased from 57,785 in 2012 to 44,378 in 2015, with radiologists responsible for 60% of all filter placements. Volume of IVC filter placement declined across all specialties, including radiologists, who placed 33,744 in 2012 and 27,957 in 2015. In contrast, total retrieval of IVC filters increased from 4,060 removals in 2012 to 6,166 in 2015. Retrieval rate per 100,000 Medicare beneficiaries increased from 11 in 2012 to 16 in 2015. Radiologists removed the bulk of the filters: 64% in both 2012 and 2015. Vascular surgeons, cardiologists, and other surgeons retrieved, respectively, 20%, 10%, and 5% of all IVC filters in 2012 and 22%, 9%, and 5% in 2015. From 2012 to 2015, IVC filter placement steadily decreased across all specialties. Retrieval rate of IVC filters continued to rise over the same period. Radiologists were responsible for the majority of IVC filter placements and retrievals. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  3. Statewide Inferior Vena Cava Filter Placement, Complications, and Retrievals: Epidemiology and Recent Trends.

    Science.gov (United States)

    Charalel, Resmi A; Durack, Jeremy C; Mao, Jialin; Ross, Joseph S; Meltzer, Andrew J; Sedrakyan, Art

    2018-03-01

    Public awareness of inferior vena cava (IVC) filter-related controversies has been elevated by the Food and Drug Administration (FDA) safety communication in 2010. To examine population level trends in IVC filter utilization, complications, retrieval rates, and subsequent pulmonary embolism (PE) risk. A retrospective cohort study. Patients receiving IVC filters during 2005-2014 in New York State. IVC filter-specific complications, new PE occurrences and IVC filter retrievals were evaluated as time-to-event data using Kaplan-Meier analysis. Estimated cumulative risks were obtained at various timepoints during follow-up. There were 91,873 patients receiving IVC filters between 2005 and 2014 in New York State included in the study. The average patient age was 67 years and 46.6% were male. Age-adjusted rates of IVC filter placement increased from 48 cases/100,000 in 2005 to 52 cases/100,000 in 2009, and decreased afterwards to 36 cases/100,000 in 2014. The estimated risks of having an IVC filter-related complication and filter retrieval within 1 year was 1.5% [95% confidence interval (CI), 1.4%-1.6%] and 3.5% (95% CI, 3.4%-3.6%). One-year retrieval rate was higher post-2010 when compared with pre-2010 years (hazard ratio, 2.70; 95% CI, 2.50-2.91). Among the 58,176 patients who did not have PE events before or at the time of IVC filter placement, the estimated risk of developing subsequent PE at 1 year was 2.0% (95% CI, 1.9%-2.1%). Our findings suggest that FDA communications may be effective in modifying statewide clinical practices. Given the 2% observed PE rate following prophylactic IVC filter placement, large scale pragmatic studies are needed to determine contemporary safety and effectiveness of IVC filters.

  4. Interruption or congenital stenosis of the inferior vena cava: Prevalence, imaging, and clinical findings

    International Nuclear Information System (INIS)

    Koc, Zafer; Oguzkurt, Levent

    2007-01-01

    Objective: To present the prevalence, clinical, and imaging findings of interruption or congenital stenotic lesions of the inferior vena cava (IVC), associated malformations, and their clinical relevance. Materials and methods: Between March 2004 and March 2006, 7972 patients who had undergone consecutive routine abdominal multidetector row computed tomography were analyzed for interruption or stenotic lesion of the IVC. Results: Prevalence of interruption (n = 8) or congenital stenosis (n = 4) of the IVC occurred in 12 (0.15%) of 7972 patients. Four patients with interruption and four patients with congenital stenosis of the IVC were symptomatic with DVT (n = 4), leg swelling (n = 4), leg pain (n = 2), lower extremity varices (n = 2), hepatic vein thrombosis (n = 1), and hematochezia (n = 1). All four of the asymptomatic patients were from the interruption group, and these patients had interrupted IVC with well-developed azygos/hemiazygos continuation. Eight symptomatic patients did not have a well-developed azygos/hemiazygos continuation, and drainage of lower extremity was mainly from collateral veins. Additional findings in eight symptomatic patients were abdominal venous collaterals (n = 8), venous aneurysm (n = 2), lower extremity varices (n = 2), varicocele (n = 2), and pelvic varices (n = 1). Conclusion: Interruption or stenosis of the IVC are rare on routine abdominal CT examinations and may cause different clinical findings depending on the variant drainage patterns or collaterals. Interrupted IVC is commonly asymptomatic if associated with well-developed azygos/hemiazygos continuation, whereas commonly symptomatic if well-developed azygos/hemiazygos continuation is not present

  5. Pre-Clinical Model to Study Recurrent Venous Thrombosis in the Inferior Vena Cava.

    Science.gov (United States)

    Andraska, Elizabeth A; Luke, Catherine E; Elfline, Megan A; Henke, Samuel P; Madapoosi, Siddharth S; Metz, Allan K; Hoinville, Megan E; Wakefield, Thomas W; Henke, Peter K; Diaz, Jose A

    2018-06-01

     Patients undergoing deep vein thrombosis (VT) have over 30% recurrence, directly increasing their risk of post-thrombotic syndrome. Current murine models of inferior vena cava (IVC) VT model host one thrombosis event.  We aimed to develop a murine model to study IVC recurrent VT in mice.  An initial VT was induced using the electrolytic IVC model (EIM) with constant blood flow. This approach takes advantage of the restored vein lumen 21 days after a single VT event in the EIM demonstrated by ultrasound. We then induced a second VT 21 days later, using either EIM or an IVC ligation model for comparison. The control groups were a sham surgery and, 21 days later, either EIM or IVC ligation. IVC wall and thrombus were harvested 2 days after the second insult and analysed for IVC and thrombus size, gene expression of fibrotic markers, histology for collagen and Western blot for citrullinated histone 3 (Cit-H3) and fibrin.  Ultrasound confirmed the first VT and its progressive resolution with an anatomical channel allowing room for the second thrombus by day 21. As compared with a primary VT, recurrent VT has heavier walls with significant up-regulation of transforming growth factor-β (TGF-β), elastin, interleukin (IL)-6, matrix metallopeptidase 9 (MMP9), MMP2 and a thrombus with high citrullinated histone-3 and fibrin content.  Experimental recurrent thrombi are structurally and compositionally different from the primary VT, with a greater pro-fibrotic remodelling vein wall profile. This work provides a VT recurrence IVC model that will help to improve the current understanding of the biological mechanisms and directed treatment of recurrent VT. Schattauer GmbH Stuttgart.

  6. Improving inferior vena cava filter retrieval rates with the define, measure, analyze, improve, control methodology.

    Science.gov (United States)

    Sutphin, Patrick D; Reis, Stephen P; McKune, Angie; Ravanzo, Maria; Kalva, Sanjeeva P; Pillai, Anil K

    2015-04-01

    To design a sustainable process to improve optional inferior vena cava (IVC) filter retrieval rates based on the Define, Measure, Analyze, Improve, Control (DMAIC) methodology of the Six Sigma process improvement paradigm. DMAIC, an acronym for Define, Measure, Analyze, Improve, and Control, was employed to design and implement a quality improvement project to increase IVC filter retrieval rates at a tertiary academic hospital. Retrievable IVC filters were placed in 139 patients over a 2-year period. The baseline IVC filter retrieval rate (n = 51) was reviewed through a retrospective analysis, and two strategies were devised to improve the filter retrieval rate: (a) mailing of letters to clinicians and patients for patients who had filters placed within 8 months of implementation of the project (n = 43) and (b) a prospective automated scheduling of a clinic visit at 4 weeks after filter placement for all new patients (n = 45). The effectiveness of these strategies was assessed by measuring the filter retrieval rates and estimated increase in revenue to interventional radiology. IVC filter retrieval rates increased from a baseline of 8% to 40% with the mailing of letters and to 52% with the automated scheduling of a clinic visit 4 weeks after IVC filter placement. The estimated revenue per 100 IVC filters placed increased from $2,249 to $10,518 with the mailing of letters and to $17,022 with the automated scheduling of a clinic visit. Using the DMAIC methodology, a simple and sustainable quality improvement intervention was devised that markedly improved IVC filter retrieval rates in eligible patients. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  7. British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry

    International Nuclear Information System (INIS)

    Uberoi, Raman; Tapping, Charles Ross; Chalmers, Nicholas; Allgar, Victoria

    2013-01-01

    Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertion and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate ( 9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up

  8. Factors affecting Cook Gunther Tulip and Cook Celect inferior vena cava filter retrieval success.

    Science.gov (United States)

    Glocker, Roan J; Novak, Zdenek; Matthews, Thomas C; Patterson, Mark A; Jordan, William D; Pearce, Benjamin J; Passman, Marc A

    2014-01-01

    Success rates vary for the retrieval of inferior vena cava filters (IVCFs). The optimal retrieval time and factors influencing retrieval success remain unproven. This study aims to determine optimal time and evaluate factors related to successful IVCF retrieval. An institutional prospectively maintained database was reviewed for all IVCF retrieval attempts from 2006 to 2012. Patient demographics, comorbidities, indications for procedure, placement technique, IVCF type, presence of angulation, and time to retrieval were evaluated with respect to success or failure of retrieval. Statistical analyses (t-test, χ(2), correlations, and Kaplan-Meier plots) were performed comparing successful and unsuccessful retrievals. Of 121 attempted IVCF retrievals, 92 (76%) were successful and 29 (24%) were unsuccessful. There were no significant differences between the successful and unsuccessful attempts in terms of patient demographics, comorbidities, indications for procedure, placement technique, or IVCF type, which included 93 Celect (77%) and 28 Gunther Tulip (23%). Time since IVCF placement was significantly different (P = .025) between the successful and unsuccessful retrieval groups (medians were 105 [7-368] and 162 [43-379] days, respectively). Time since IVCF placement greater than 117 days correlated significantly with unsuccessful IVCF retrieval (R = 0.218; P = .017; odds ratio, 2.88; P = .02). Angulation greater than 20 degrees on anteroposterior radiograph was noted in seven of 29 (24%) unsuccessful retrievals compared with seven of 92 (8%) successful retrievals and was significant (P = .012). Cook Gunther Tulip and Celect IVCF retrieval is most likely to be successful within 3 to 4 months of placement. Unsuccessful retrieval attempts are more likely to occur when IVCF position is angulated. Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. Use of a Trellis Device for Endovascular Treatment of Venous Thrombosis Involving a Duplicated Inferior Vena Cava

    Energy Technology Data Exchange (ETDEWEB)

    Saettele, Megan R., E-mail: SaetteleM@umkc.edu [University of Missouri, Kansas City, Department of Radiology, Saint Luke' s Hospital (United States); Morelli, John N., E-mail: dr.john.morelli@gmail.com [Texas A and M University Health Science Center, Department of Radiology, Scott and White Clinic and Hospital (United States); Chesis, Paul; Wible, Brandt C. [University of Missouri, Kansas City, Department of Interventional Radiology, Saint Luke' s Hospital (United States)

    2013-12-15

    Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot involving the infrarenal segment of a duplicated left IVC who underwent pharmacomechanical thrombectomy and tissue plasminogen activator catheter-directed thrombolysis with complete deep venous thrombosis resolution. To our knowledge this is the first reported case in the English literature of the use of a Trellis thrombectomy catheter in the setting of duplicated IVC.

  10. Are too many inferior vena cava filters used? Controversial evidences in different clinical settings: a narrative review.

    Science.gov (United States)

    Dalla Vestra, Michele; Grolla, Elisabetta; Bonanni, Luca; Pesavento, Raffaele

    2018-03-01

    The use of inferior vena cava filters to prevent pulmonary embolism is increasing mainly because of indications that appear to be unclearly codified and recommended. The evidence supporting this approach is often heterogeneous, and mainly based on observational studies and consensus opinions, while the insertion of an IVC filter exposes patients to the risk of complications and increases health care costs. Thus, several proposed indications for an IVC filter placement remain controversial. We attempt to review the proof on the efficacy and safety of IVC filters in several "special" clinical settings, and assess the robustness of the available evidence for any specific indication to place an IVC filter.

  11. CT Findings of Intrarenal Yolk Sac Tumor with Tumor Thrombus Extending into the Inferior Vena Cava: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Shao Chun; Li, Xue Hua; Sun, Can Hui; Feng, Shi Ting; Peng, Zhen Peng; Huang, Si Yun; Li, Zi Ping [Dept. of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China)

    2014-10-15

    Yolk sac tumor (YST) is a rare germ cell neoplasm of childhood that usually arises from the testis or ovary. The rare cases of YST in various extragonadal locations have been reported, but the primary intrarenal YST is even more uncommon. Here, we report a case of a primary intrarenal YST with tumor thrombus of the inferior vena cava and left renal vein in a 2-year-old boy, with an emphasis on the CT features. To our knowledge, this is the first reported case of an intrarenal YST with intravascular involvement.

  12. British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry

    Energy Technology Data Exchange (ETDEWEB)

    Uberoi, Raman, E-mail: raman.Uberoi@orh.nhs.uk; Tapping, Charles Ross [Oxford University Hospitals, John Radcliffe Hospital, Department of Radiology (United Kingdom); Chalmers, Nicholas [Manchester Royal Infirmary, Department of Radiology (United Kingdom); Allgar, Victoria [University of York, Hull and York Medical School (United Kingdom)

    2013-12-15

    Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertion and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter

  13. Use of Retrievable Compared to Permanent Inferior Vena Cava Filters: A Single-Institution Experience

    International Nuclear Information System (INIS)

    Ha, Thuong G. Van; Chien, Andy S.; Funaki, Brian S.; Lorenz, Jonathan; Piano, Giancarlo; Shen, Maxine; Leef, Jeffrey

    2008-01-01

    The purpose of this study was to review the use, safety, and efficacy of retrievable inferior vena cava (IVC) filters in their first 5 years of availability at our institution. Comparison was made with permanent filters placed in the same period. A retrospective review of IVC filter implantations was performed from September, 1999, to September, 2004, in our department. These included both retrievable and permanent filters. The Recovery nitinol and Guenther tulip filters were used as retrievable filters. The frequency of retrievable filter used was calculated. Clinical data and technical data related to filter placement were reviewed. Outcomes, including pulmonary embolism, complications associated with placement, retrieval, or indwelling, were calculated. During the study period, 604 IVC filters were placed. Of these, 97 retrievable filters (16%) were placed in 96 patients. There were 53 Recovery filter and 44 Tulip filter insertions. Subjects were 59 women and 37 men; the mean age was 52 years, with a range of from 18 to 97 years. The placement of retrievable filters increased from 2% in year 1 to 32% in year 5 of the study period. The total implantation time for the permanent group was 145,450 days, with an average of 288 days (range, 33-1811 days). For the retrievable group, the total implantation time was 21,671 days, with an average of 226 days (range, 2-1217 days). Of 29 patients who returned for filter retrieval, the filter was successfully removed in 28. There were 14 of 14 successful Tulip filter retrievals and 14 of 15 successful Recovery filter retrievals. In one patient, after an indwelling period of 39 days, a Recovery nitinol filter could not be removed secondary to a large clot burden within the filter. For the filters that were removed, the mean dwell time was 50 days for the Tulip type and 20 days for the Recovery type. Over the follow-up period there was an overall PE incidence of 1.4% for the permanent group and 1% for the retrieval group. In

  14. Obstruction of hepatic vein or inferior vena cava after liver transplantation: the diagnosis and interventional treatment

    International Nuclear Information System (INIS)

    Zhu Kangshun; Qian Jiesheng; Meng Xiaochun; Yi Shuhong; Pang Pengfei; He Keke; Jiang Zaibo; Lu Minqiang; Shan Hong

    2010-01-01

    Objective: To investigate the diagnosis and interventional therapeutic technology for the obstruction of hepatic vein (HV) or inferior vena cava (IVC) after liver transplantation. Methods: In the 831 patients who received orthotopic liver transplantation (OLT) and 26 patients who received living donor liver transplantation (LDLT), 11 cases were confirmed with HV or IVC obstruction by venography and received interventional treatment from 2 to 111 days after liver transplantation. Of the 11 patients, five had the obstruction of HV anastomosis, five had the obstruction of IVC anastomosis, and one had the obstruction of HV and IVC anastomosis. In the eleven patients, five patients underwent OLT, four patients underwent LDLT, and two pediatric patients underwent reduced-size OLT. Before interventional treatment, 9 patients function tests, clinical sympatom, and monitoring of HV or IVC flow. Pressure gradients before and after therapeutic technology of 11 cases were retrospectively analyzed. Results: In all 11 patients, CT or MRI could clearly show congested areas of the liver, and the location and degree of HV or IVC obstruction. Of the 11 patients, four with HV obstruction and five with IVC obstruction were treated with stent placement, one with HV obstruction was treated with percutaneous transluminal angioplasty (PTA), one with HV and IVC obstruction was treated with HV PTA and IVC stent placement. Interventional technical success was achieved in all patients. The venous pressure gradient across obstruction was significantly reduced from (16.5 ± 4.1) mm Hg (1 mm Hg =0.133 kPa) before the procedure to (2.9 ± 1.7) mm Hg after the procedure (t=11.5, P<0.01). Clinical improvement was noted in 10 patients except one pediatric patient who died of multiple-organs failure at the 9 th day after the treatment. During the follow-up period of 9 to 672 days, two patients with PTA treatment had recurrent HV stenosis within one month after treatment, no patient with stent

  15. Physiologic Effect of Stent Therapy for Inferior Vena Cava Obstruction Due to Malignant Liver Tumor

    International Nuclear Information System (INIS)

    Kishi, Kazushi; Sonomura, Tetsuo; Fujimoto, Hisashi; Kimura, Masashi; Yamada, Katsuya; Sato, Morio; Juri, Masanobu

    2006-01-01

    Purpose. To understand systemic the influence of stent therapy for inferior vena cava (IVC) obstruction due to advanced liver tumor. Methods. Seven patients with symptomatic IVC obstruction due to advanced primary (n 4) or secondary (n = 3) liver tumor were subjected to stent therapy. Enrollment criteria included high IVC pressure over 15 mmHg and the presence of edema and ascites. Z-stents were deployed using coaxial sheath technique via femoral venous puncture. Physiologic and hematobiochemical parameters were analyzed. Results. All procedures were successful, and the stents remained patent until patient death. Promptly after stent placement, the IVC flow recovered, and the venous blood pressure in the IVC below the obstruction level showed a significant decrease from 20.8 ± 1.2 mmHg (mean ± SE) to 10.7 ± 0.7 mmHg (p 0.6) with the urine volume increase, and with the decreased volume of edema and ascites. The urine volume increase correlated well with the decrement of edema, but not with that of ascites. Improvements for various durations in the levels of blood urea nitrogen, serum creatinine, lactate dehydrogenase, fibrinogen, and platelet count were found (p < 0.05). These hematobiochemical changes were well correlated with each other and with the decrement of ascites. Two patients showed a low blood sodium level of 128.5 mEq/l after intensive natriuresis, and one of them died on day 21 with hepatic failure, which was interpreted as maladaptation aggravation. The mean survival time was 94.1 ± 34.1 days (mean ± SD), ranging from 21 to 140 days after stent treatment. Conclusion. The stent therapy for IVC obstruction due to malignant liver tumors was followed by a series of physiologic and hematobiochemical consequences, most of them favorable but some possibly unfavorable. Rational interpretations and predictions of sequelae based on physiologic science including cardiology, hepatology, and nephrology would facilitate the best management of stent therapy for

  16. Clinical research of the obstructive interface morphology of the inferior vena cava and the method of choice for taking the 'pierce membrane'

    International Nuclear Information System (INIS)

    Wei Ning; Zu Maoheng; Xu Hao; Gu Yuming; Li Guojun; Zhang Qingqiao; Xu Wei; Liu Hongtao

    2008-01-01

    Objective: To evaluate the relation between the morphology of the obstructive interface of the inferior vena cava (IVC)and the method of choice for taking the 'pierce membrane'. Methods: Interventional therapy was performed in 155 patients with obstruction of inferior vena cave during 2003-2005. The types of proximal part and distal end of obstruction were classified on the base of inferior vane cavography and divid[d into two groups accordingly. The principle of taking 'pierce membrane' whether as accending or descending route was decided by the morphology of the obstructive interface. The complication rates of taking 'pierce membrane' were compared between the two groups including one of 2003-2005 and another of 1990 -1997 as the control. Results: 155 cases were classified to 7 types according to morphology of inferior vena cava obstruction of the distal interface, the type of membrane with hole (32 cases), the dome type (50 cases), the taper type (17 cases), the horizontal type (13 cases), the inclination type (10 cases), the irregular type (19 eases)and the type of obstruction with communicating branches (14 cases). The morphologies of the proximal part of the obstruction were mainly divided into the type of membrane with hole, dome type, taper type and horizontal type. All the cases were successfully taken 'pierce membrane', without complication of pericardial effusion and abdominal bleeding. In control group of 150 Budd-Chiari syndrome cases with obstruction of inferior vena cava, the complications of taking 'pierce membrane' included mis puncture into pericardium (16 cases) and abdominal hemorrhage because of rupturing the inferior vena cava in 2 cases. Comparing the two groups, there was statistical significance with severe complications. Conclusions: 'Pierce membrane' interventional technique for the obstruction of inferior vena eava by coinciding the morphology of the obstructive interface with suitable piercing direction can not only raise successful

  17. Should We Remove the Retrievable Cook Celect Inferior Vena Cava Filter? Eight Years of Experience at a Single Center.

    Science.gov (United States)

    Son, Joohyung; Bae, Miju; Chung, Sung Woon; Lee, Chung Won; Huh, Up; Song, Seunghwan

    2017-12-01

    The inferior vena cava filter (IVCF) is very effective for preventing pulmonary embolism in patients who cannot undergo anticoagulation therapy. However, if a filter is placed in the body permanently, it may lead to other complications. A retrospective study was performed of 159 patients who underwent retrievable Cook Celect IVCF implantation between January 2007 and April 2015 at a single center. Baseline characteristics, indications, and complications caused by the filter were investigated. The most common underlying disease of patients receiving the filter was cancer (24.3%). Venous thrombolysis or thrombectomy was the most common indication for IVCF insertion in this study (47.2%). The most common complication was inferior vena cava penetration, the risk of which increased the longer the filter remained in the body (p=0.032, Exp(B)=1.004). If the patient is able to retry anticoagulation therapy and the filter is no longer needed, the filter should be removed, even if a long time has elapsed since implantation. If the filter cannot be removed, it is recommended that follow-up computed tomography be performed regularly to monitor the progress of venous thromboembolisms as well as any filter-related complications.

  18. Angiographic and hemodynamic evaluation of the mesoatrial shunt in patients with Budd-Chiari syndrome and inferior vena caval obstruction

    International Nuclear Information System (INIS)

    Redmond, P.L.; Kadir, S.; Cameron, J.L.; Kaufman, S.L.; White, R.I. Jr.

    1986-01-01

    Obstruction of the inferior vena cava (IVC) is not uncommon in patients with the Budd-Chiari syndrome. The caval obstruction may be due to thrombus or compression by an enlarged caudate lobe. Conventional portosystemic shunts are not possible in the presence of an obstructed IVC; the mesoatrial shunt is indicated in these patients. Between 1973 and 1986, the authors studied 13 patients (ten female, three male) with Budd-Chiari syndrome and IVC obstruction in whom mesoatrial shunts were subsequently constructed. Polycythemia rubra vera was the most common predisposing condition. Preoperative evaluation included US, scintigraphy, CT, and angiography (hepatic arteriography, hepatic venography and pressure measurements, inferior vena cavography, arterial portography). Postoperatively shunts were assessed angiographically and hemodynamically, and several patients underwent CT. The shunts were catheterized via a brachial or femoral venous approach, which allowed pressures along the shunt from the superior mesenteric vein to the right atrium to be measured. The mesoatrial shunt is a relatively new procedure which is indicated in patients with the Budd-Chiari syndrome complicated by IVC obstruction. Shunt patency may be demonstrated arteriographically or with CT, but hemodynamic evaluation with measurement of pressure gradients is required to assess shunt function

  19. Correlation of inferior vena cava (ivc) diameter and central venous pressure (cvp) for fluid monitoring in icu

    International Nuclear Information System (INIS)

    Khalil, A.; Hayat, A.

    2015-01-01

    To determine intravascular fluid status in critically ill patients using inferior vena cava diameter and correlating it with central venous pressure. Study Design: Cross sectional study. Place and Duration of Study: Intensive care department, Military Hospital Rawalpindi from Jan 2013 to Aug 2013. Material and Methods: We included 115 adult patients of both genders in age range of 18 to 87 years by consecutive sampling admitted in intensive care unit. Ultrasound guided IVC diameter was assessed in supine patients. Data was simultaneously collected from the CVP catheter. Variables included in study were age, gender, CVP, IVC diameter. Results: CVP ranged from -4 to 26 cm H/sub 2/O with mean of 8 cm H/sub 2/O (SD = 6.24). Mean IVC diameters increased with increase in CVP. Correlation between CVP and max IVC diameter was moderate and significant (r = 0.53, p < 0.001). Correlation between CVP and min IVC diameter was also moderate and significant (r = 0.58, p < 0.001). Conclusion: A simple bedside sonography of inferior vena cava diameter correlates well with extremes of CVP values and can be helpful in assessing intravascular fluid status in these patients. (author)

  20. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    International Nuclear Information System (INIS)

    Stambo, Glenn W.; Leto, John; George, Christopher; Van Epps, Kelly; Woeste, Troy; Berlet, Mathew

    2008-01-01

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus

  1. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    Energy Technology Data Exchange (ETDEWEB)

    Stambo, Glenn W. [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)], E-mail: xraydoc2@yahoo.com; Leto, John [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 3001 W. Dr. Martin Luther King Jr. Blvd., Tampa, FL 33607 (United States); George, Christopher [Department of Hematology and Oncology, St. Joseph' s Hospital and Medical Center, 4301 W. Habana Avenue, Suite 1, Tampa, FL 33607 (United States); Van Epps, Kelly; Woeste, Troy; Berlet, Mathew [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)

    2008-05-15

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus.

  2. Should We Remove the Retrievable Cook Celect Inferior Vena Cava Filter? Eight Years of Experience at a Single Center

    Directory of Open Access Journals (Sweden)

    Joohyung Son

    2017-12-01

    Full Text Available Background: The inferior vena cava filter (IVCF is very effective for preventing pulmonary embolism in pa-tients who cannot undergo anticoagulation therapy. However, if a filter is placed in the body permanently, it may lead to other complications. Methods: A retrospective study was performed of 159 patients who under-went retrievable Cook Celect IVCF implantation between January 2007 and April 2015 at a single center. Baseline characteristics, indications, and complications caused by the filter were investigated. Results: The most common underlying disease of patients receiving the filter was cancer (24.3%. Venous thrombolysis or thrombectomy was the most common indication for IVCF insertion in this study (47.2%. The most common complication was inferior vena cava penetration, the risk of which increased the longer the filter remained in the body (p=0.032, Exp(B=1.004. Conclusion: If the patient is able to retry anticoagulation therapy and the filter is no longer needed, the filter should be removed, even if a long time has elapsed since implantation. If the filter cannot be removed, it is recommended that follow-up computed tomography be performed regularly to monitor the progress of venous thromboembolisms as well as any filter-related complications.

  3. Inferior vena cava filter thrombus: A possible cause of an unanticipated finding of {sup 99m} Tc-labeled red blood cell scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hee Sung; Choi, Joon Hyouk; Kim, Young Suk [Jeju National University School of Medicine, Jeju (Korea, Republic of)

    2016-06-15

    {sup 99m}Tc-labeled red blood cell scintigraphy, a sensitive and specific diagnostic test, is useful for patients suspected of suffering from active gastrointestinal bleeding. This study follows a case of a patient who was suspected of gastrointestinal bleeding after an inferior vena cava filter was inserted due to a deep vein thrombosis of the femoral vein. To evaluate an exact focus of bleeding, {sup 99m}Tc-labeled red blood cell scintigraphy was executed. Herein, an unanticipated finding of {sup 99m}Tc-labeled red blood cell scintigraphy probably due to a thrombus on the inferior vena cava filter is reported.

  4. Congenital anomalies of the inferior vena cava: importance of multiplanar imaging methods: an iconographic essay; Anomalias congenitas da veia cava inferior: valor dos metodos multiplanares em seu diagnostico - ensaio iconografico

    Energy Technology Data Exchange (ETDEWEB)

    Viana, Sergio Lopes; Mendonca, Jose Luiz Furtado de; Freitas, Flavia Mendes Oliveira [Clinica Radiologica Vila Rica, Brasilia, DF (Brazil)] (and others). E-mail: radiolog@uol.com.br

    2006-10-15

    The inferior vena cava is the result of a complex embryologic process which takes place between 6 and 8 weeks of intra-uterine life. Several variations can occur during this process, and a defective embryogenesis of this vessel may lead to the development of anatomic variants. Although many of these variants are asymptomatic, the radiologist should be aware of them and of the potential medico-legal issues involved, especially in cases in which abdominal surgery or hemodynamic procedures are contemplated. In this paper, the major congenital anomalies involving the inferior vena cava are reviewed under the form of a pictorial essay, highlighting the role of the multiplanar imaging methods (volumetric computed tomography and magnetic resonance imaging) in their diagnosis. Keywords: Congenital variations; Inferior vena cava; Renal veins; Computed tomography; Magnetic resonance imaging. author)

  5. Experimental investigation of the effects of inserting a bovine venous valve in the inferior vena cava of Fontan circulation

    Science.gov (United States)

    Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin

    2012-11-01

    The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.

  6. Caval penetration by retrievable inferior vena cava filters: a retrospective comparison of Option and Günther Tulip filters.

    Science.gov (United States)

    Olorunsola, Olufoladare G; Kohi, Maureen P; Fidelman, Nicholas; Westphalen, Antonio C; Kolli, Pallav K; Taylor, Andrew G; Gordon, Roy L; LaBerge, Jeanne M; Kerlan, Robert K

    2013-04-01

    To compare the frequency of vena caval penetration by the struts of the Option and Günther Tulip cone filters on postplacement computed tomography (CT) imaging. All patients who had an Option or Günther Tulip inferior vena cava (IVC) filter placed between January 2010 and May 2012 were identified retrospectively from medical records. Of the 208 IVC filters placed, the positions of 58 devices (21 Option filters, 37 Günther Tulip filters [GTFs]) were documented on follow-up CT examinations obtained for reasons unrelated to filter placement. In cases when multiple CT studies were obtained after placement, each study was reviewed, for a total of 80 examinations. Images were assessed for evidence of caval wall penetration by filter components, noting the number of penetrating struts and any effect on pericaval tissues. Penetration of at least one strut was observed in 17% of all filters imaged by CT between 1 and 447 days following placement. Although there was no significant difference in the overall prevalence of penetration when comparing the Option filter and GTF (Option, 10%; GTF, 22%), only GTFs showed time-dependent penetration, with penetration becoming more likely after prolonged indwelling times. No patient had damage to pericaval tissues or documented symptoms attributed to penetration. Although the Günther Tulip and Option filters exhibit caval penetration at CT imaging, only the GTF exhibits progressive penetration over time. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  7. Ante situm liver resection with inferior vena cava replacement under hypothermic cardiopolmunary bypass for hepatoblastoma: Report of a case and review of the literature

    Directory of Open Access Journals (Sweden)

    Roberta Angelico

    2017-01-01

    Conclusions: We report for the first time a case of ante situ liver resection and inferior-vena-cava replacement associated with hypothermic cardiopulmonary bypass in a child with hepatoblastoma. Herein, we extensively review the literature for hepatoblastoma with thumoral thrombi and we describe the technical aspects of ante situm approach, which is a realistic option in otherwise unresectable hepatoblastoma.

  8. Transfemoral Filter Eversion Technique following Unsuccessful Retrieval of Option Inferior Vena Cava Filters: A Single Center Experience.

    Science.gov (United States)

    Posham, Raghuram; Fischman, Aaron M; Nowakowski, Francis S; Bishay, Vivian L; Biederman, Derek M; Virk, Jaskirat S; Kim, Edward; Patel, Rahul S; Lookstein, Robert A

    2017-06-01

    This report describes the technical feasibility of using the filter eversion technique after unsuccessful retrieval attempts of Option and Option ELITE (Argon Medical Devices, Inc, Athens, Texas) inferior vena cava (IVC) filters. This technique entails the use of endoscopic forceps to evert this specific brand of IVC filter into a sheath inserted into the common femoral vein, in the opposite direction in which the filter is designed to be removed. Filter eversion was attempted in 25 cases with a median dwell time of 134 days (range, 44-2,124 d). Retrieval success was 100% (25/25 cases), with an overall complication rate of 8%. This technique warrants further study. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  9. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    International Nuclear Information System (INIS)

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L.

    2010-01-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  10. Interventional therapy and complications after liver transplantation: the obstruction of the hepatic vein and inferior vena cava

    International Nuclear Information System (INIS)

    Li Linsun; Shi Haibing; Zhao Linbo

    2009-01-01

    The occurrence rate of the obstruction of the hepatic vein or the inferior vena cava is very low. Obstruction can develop acutely as a result of technical problems or can present itself much later after the transplantation due to intimal hyperplasia or perianastomotic fibrosis. Clinically, the common presentations include hepatic dysfunction, liver engorgement, ascites, abdominal pain, etc. Percutaneous endovascular treatment with balloon dilation or stent placement is a safe and effective alternative treatment, which can keep the vessels open for a long period of time. Angioplasty can achieve technical success in restoring anastomotic patency almost to 100% of cases, but, unfortunately, restenosis occurs frequently. For, adult patients or pediatric patients with adult-sized hepatic veins, stenting seems to be the optimal choice. (authors)

  11. Budd-chiari syndrome by membranous obstruction of inferior vena cava: comparison of sonography and computed tomography

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Lim, Jae Hoon; Ko, Young Tae; Yoon, Yup; Lim, Joo Won

    1992-01-01

    Membranous obstruction of the hepatic inferior vena cava (MOVC) is one of the common causes of Budd-Chiari syndrome. The aim of this study is to ascertain and compare the characteristic sonographic and CT findings of Budd-Chiari syndrome caused by MOVC. We studied 10 patients of Budd-Chiari syndrome caused by MOVC thorough sonography and CT. MOVC was confirmed by operation and/or inferior vena cavography. The cases included 9 men and one woman. With sonography, IVC obstruction was diagnosed in 9 cases. The cause of IVC obstruction was web in 5 cases and fibrous cord in 3 cases. The cause was unspecified in one case. Obliteration of the hepatic veins and intrahepatic collateral vessels were delineated in 9 cases. With color doppler sonography, the directions of blood flow of the hepatic veins through the intervenous communication were fairly well demonstrated in all 5 cases. With CT, IVC obstruction was diagnosed in 7 cases. The obliteration of the hepatic segment of the IVC were segmental in 6 cases and diffuse in one case. CT demonstrated communicating vessels between the hepatic veins in 3 cases. Furthermore, systemic collateral vessels (azygos and hemiazygos veins, veins along the abdominal wall, and internal mammary veins) were demonstrated in all cases. Liver cirrhosis was combined in all cases and hepatoma developed in 4 cases. Sonography is useful to detect the MOVC and to demonstrate hepatic venous obstruction and intrahepatic collateral vessels. Color doppler sonography is easily performed to show the direction of the blood flow through interconnecting vessels. CT shows the obliterated segment of the IVC clearly and multiple prominent systemic collaterals. In conclusion, Budd-Chiari syndrome caused by MOVC is accurately diagnosed by combined color doppler sonography and CT

  12. Multi-slice spiral CT multiplanar reconstruction findings of localized fat collection adjection to the subdiaphragmatic inferior vena cava

    International Nuclear Information System (INIS)

    Cao Hetao; Lu Jian; Zhao Jinli; Liu Tingting; Qin Jufeng; Xu Wen; Qin Jiangchun; Jiang Junkang

    2012-01-01

    Objective: To discusses the MSCT multiplanar reconstruction manifestation (MPR) of localized fat collection adjection to subdiaphragmatic inferior vena cava (IVC fat ). Methods: The thoracic and abdominal MSCT scan data of 8246 patients were browsed,45 patients with presumed IVC fat on axial CT scans were further studied prospectively with MSCT MPR. The predisposing position of IVC fat and its relationship with IVC were observed. It was divided into two kinds of intraluminal type and extraluminal type according to the angle of IVC fat with respect of the wall of IVC.The other 50 patients without IVC fat were randomly selected as the control group. The sagittal inclination angle (SIA) and diameter ratio (DR) between supra- and sub-diaphragmatic IVC between the two groups were compared by using t test. Results: The detection rate was 0.55% (45/8246). Of which hepatic vein lacuna 8 patients, subdiaphragmatic gap medial to IVC 28 patients and IVC groove 9 patients. The shape of IVC fat showed mainly for the round, oval and crescents on axial CT scans, of 15 patients intraluminal type, 4 showed 'target signs'. The shape of IVC fat showed mainly for 'half-moon' at MPR.The SIA and DR at IVC fat group were 21.62° ± 8.42° and 2.01 ±0.84 respectively, at control group were 16.75° ±7.82° (t=1.594, P>0.05) and 1.31 ±0.28 (t=2.341, P<0.05) respectively. Conclusion: The round, oval or half of limited fat density shadow adjection to subdiaphragmatic inferior vena cava which similar to in the lumen is the characteristic performance of IVC fat , it may be an anatomical variation. (authors)

  13. Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters

    Directory of Open Access Journals (Sweden)

    Robinson RA

    2013-05-01

    Full Text Available Ronald A Robinson, Luke H Herbertson, Srilekha Sarkar Das, Richard A Malinauskas, William F Pritchard, Laurence W GrossmanOffice of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, USAAbstract: The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm, length-to-diameter ratios (1:1, 3:1, 10:1, and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the

  14. Particle radiotherapy, a novel external radiation therapy, versus liver resection for hepatocellular carcinoma accompanied with inferior vena cava tumor thrombus: A matched-pair analysis.

    Science.gov (United States)

    Komatsu, Shohei; Kido, Masahiro; Asari, Sadaki; Toyama, Hirochika; Ajiki, Tetsuo; Demizu, Yusuke; Terashima, Kazuki; Okimoto, Tomoaki; Sasaki, Ryohei; Fukumoto, Takumi

    2017-12-01

    Hepatocellular carcinoma accompanied with inferior vena cava tumor thrombus carries a dismal prognosis, and the feasibility of local treatment has remained controversial. The present study aimed to compare the outcomes of particle radiotherapy and liver resection in patients with hepatocellular carcinoma with inferior vena cava tumor thrombus. Thirty-one and 19 patients, respectively, underwent particle radiotherapy and liver resection for hepatocellular carcinoma with inferior vena cava tumor thrombus. A matched-pair analysis was undertaken to compare the short- and long-term outcomes according to tumor stage determined using the tumor-node-metastasis classification. Both stages IIIB and IV (IVA and IVB) patients were well-matched for 12 factors, including treatment policy and patient and tumor characteristics. The median survival time of matched patients with stage IIIB tumors in the particle radiotherapy group was greater than that in the liver resection group (748 vs 272 days, P = .029), whereas no significant difference was observed in the median survival times of patients with stage IV tumors (239 vs 311 days, respectively). There were significantly fewer treatment-related complications of grade 3 or greater in the particle radiotherapy group (0%) than in the liver resection group (26%). Particle radiotherapy is potentially preferable in hepatocellular carcinoma patients with stage IIIB inferior vena cava tumor thrombus and at least equal in efficiency to liver resection in those with stage IV disease, while causing significantly fewer complications. Considering the relatively high survival and low invasiveness of particle radiotherapy when compared to liver resection, this approach may represent a novel treatment modality for hepatocellular carcinoma with inferior vena cava tumor thrombus. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Reproduction of a new inferior vena cava thrombosis model and study of the evolutionary process of thrombolysis in rats

    Directory of Open Access Journals (Sweden)

    Jian FU

    2015-10-01

    Full Text Available Objective To investigate the reproduction of a new model of thrombosis of inferior vena cava (IVC, and explore the natural process of thrombolysis and its mechanism in rats. Methods Forty-eight SD rats were randomly classified into experimental group and control group. In the experimental group, the lumen of the vena cava was blocked by about 80%-90% with a ligature of IVC below the left renal vein, and then the animals were redivided into three subgroups (n=12, each. In group A, the IVC endothelium was damaged and its tributaries were ligated. In group B, the IVC endothelium was damaged and its tributaries were not ligated. In group C, no damage was done to the endothelium of the IVC but all its tributaries were ligated. A sham-operated group served as control. The length and weight of the vinous thrombus and the percentage of the IVC luminal area were compared after operation to determine the optimum animal model of venous thrombosis. According to the best mode to establish the model, the thrombus specimens were collected and detected by HE and Masson staining, and the ED-1 expressions were examined by immunohistochemical staining after thrombus formation in 30 rats. The natural evolution of intravenous thrombolysis was analyzed dynamically and the cell types involved in this process were observed. Results Gross observation showed that the experimental group was successfully induced thrombus formation. The thrombus length and weight in group A was significantly higher than that in group B and group C, and no difference between group B and C. The thrombus area in group A was significantly higher than that in groups B and group C, which identified the group A was the optimal model group of venous thrombosis. In the group reproduced by the best mode of the model, HE and Masson staining results showed that new capillaries and the components of collagen and extracellular matrix increased gradually with the passage of time in the process of

  16. Reverse Trendelenburg position is a safer technique for lowering central venous pressure without decreasing blood pressure than clamping of the inferior vena cava below the liver.

    Science.gov (United States)

    Yoneda, Godai; Katagiri, Satoshi; Yamamoto, Masakazu

    2015-06-01

    Bleeding remains an important intraoperative complication in patients who undergo hepatectomy. It is generally believed that a reduction in central venous pressure will decrease bleeding from the hepatic venous system. To our knowledge, however, no study has compared the effectiveness of these techniques for controlling bleeding. So we compared the effectiveness of central venous pressure control techniques, such as infrahepatic inferior vena cava clamping, changes in surgical position of the patient, and hypoventilation anesthesia, for lowering central venous pressure. The study group comprised 50 patients who underwent hepatectomy in our department from 2012 through 2013. A central venous catheter was inserted into the right internal jugular vein, and the tip was placed in the superior vena cava. A transducer was placed along the mid-axillary line of the left side of the chest. After opening the abdomen, changes in central venous pressure were measured during inferior vena cava clamping, the reverse Trendelenburg position, the Trendelenburg position, and hypoventilation anesthesia. The inclination relative to the transducer, as measured with an inclinometer, was -10 degrees for the Trendelenburg position and +10 degrees for the reverse Trendelenburg position. The tidal volume was set at 10 mL/kg during conventional anesthesia and 5 mL/kg during hypoventilation anesthesia. The mean central venous pressure was 8.0 cm H(2)O in the supine position during conventional anesthesia, 5.0 cm H(2)O during inferior vena cava clamping, 5.6 cm H(2)O during reverse Trendelenburg position, 10.6 cm H(2)O during Trendelenburg position, and 7.6 cm H(2)O during hypoventilation anesthesia. The mean central venous pressure during inferior vena cava clamping and reverse Trendelenburg position was significantly lower than that during supine position (P = 0.0017 and P = 0.0231, respectively). The mean central venous pressure during hypoventilation

  17. Trombosis del sector ilio-cava: trombosis puerperal y trombosis en agenesia de la cava inferior Thrombosis of the ileo-caval sector: puerperal thrombosis and agenesia thrombosis of the inferior vena cava

    Directory of Open Access Journals (Sweden)

    Jorge García Egea

    2011-03-01

    Full Text Available La trombosis de la vena cava inferior supone alrededor del 15 % del total de los casos de trombosis venosa profunda. Se presenta un caso de una puérpera primigesta con parto por cesárea que presentó una trombosis con inicio en la vena ovárica derecha y extensión hasta la cava inferior. Fue tratada con heparina de bajo peso molecular en dosis anticoagulantes, reposo con extremidades elevadas y elastocompresión. Tras la evolución satisfactoria del proceso, con lisis parcial del trombo, se comenzó anticoagulación oral con acenocumarol durante 6 meses. El segundo paciente, un varón de 73 años, con antecedentes de hidatidosis hepática intervenida, presentó una trombosis de la cava inferior infrarrenal y agenesia del segmento retrohepático de la cava inferior. El enfermo sigue con tratamiento anticoagulante con acenocumarol, elastocompresión y cuidados higiénicos. Como secuela presentó un síndrome posflebítico con episodios de úlceras flebostásicas y reagudizaciones del edema, que han obligado a su hospitalización en dos ocasiones.The thrombosis of the inferior vena cava account for around the 15% of the cases of deep venous thrombosis. This is the case of a puerperal primigravida with a cesarean section labor presenting with a thrombosis initially in the right ovarian vein and then extension to the inferior vena cava. Treatment included low molecular weight heparin in anticoagulant doses; rest with elevation of the extremities and elastic bandage. After a satisfactory process evolution with partial lysis of the thrombus, the oral anticoagulation with Acenocumarol for 6 months was started. The second patient, a man aged 73 with backgrounds of an operated hepatic hydatidosis, had a thrombosis of the infrarenal inferior vena cava and agenesia of retrohepatic segment of the inferior vena cava. The patient remains with anticoagulant treatment including Acenocumarol, elastic bandage and hygienic care. As sequela he had a postphlebitic

  18. Malformação de veia cava inferior e trombose venosa profunda: fator de risco de trombose venosa em jovens Inferior vena cava malformation and deep venous thrombosis: a risk factor of venous thrombosis in the young

    Directory of Open Access Journals (Sweden)

    Renan Roque Onzi

    2007-06-01

    Full Text Available A ausência da veia cava inferior, alteração no processo de formação embriológica que ocorre entre a sexta e a oitava semanas de gestação, é uma rara anomalia congênita. Porém, recentemente foi confirmada como sendo um fator de risco importante para o desenvolvimento de trombose venosa profunda, especialmente em jovens. Apresentamos um caso de trombose em veias cava inferior, ilíacas, femorais e poplíteas num jovem de 16 anos com agenesia de um segmento de veia cava infra-renal e veia renal esquerda retroaórtica.Absence of inferior vena cava, caused by aberrant development within the sixth to eighth weeks of gestation, is a rare congenital anomaly. However, it has been recently confirmed as a major risk factor for the development of deep venous thrombosis, especially in young patients. We report a case of inferior vena cava, iliac, femoral and popliteal vein thrombosis in a 16-year-old patient with inferior vena cava agenesis and retroaortic left renal vein.

  19. An experimental and computational study of the inferior vena cava hemodynamics under respiratory-induced collapse of the infrarenal IVC.

    Science.gov (United States)

    Tedaldi, Elisabetta; Montanari, Chiara; Aycock, Kenneth I; Sturla, Francesco; Redaelli, Alberto; Manning, Keefe B

    2018-04-01

    Inferior vena cava (IVC) filters have been used for over five decades as an alternative to anticoagulation therapy in the treatment of venous thromboembolic disease. However, complications associated with IVC filters remain common. Though many studies have investigated blood flow in the IVC, the effects of respiration-induced IVC collapse have not been evaluated. Our hypothesis is that IVC collapse may have an influence on IVC filter performance. Therefore, we herein investigate the hemodynamics in uncollapsed and collapsed IVC configurations using in vitro flow experiments and computational simulations. Particle image velocimetry (PIV) is used to measure the hemodynamics in an idealized, compliant model of the human IVC made of silicone rubber. Flow is studied under uncollapsed and collapsed scenarios, with the minor diameter of the IVC reduced by 30% in the collapsed state. Both rest and exercise flow conditions are investigated, corresponding to suprarenal flow rates of 2 lpm and 5.5 lpm, respectively. Finite element analysis simulations are carried out in a computational model of the undeformed, idealized IVC to reproduce the 30% collapse configuration and an additional 50% collapse configuration. Computational fluid dynamics (CFD) simulations are then performed to predict the flow in the uncollapsed and collapsed scenarios, and CFD results are compared to the experimental data. The results show that the collapsed states generate a higher velocity jet at the iliac junction that propagates farther into the lumen of the vena cava in comparison to the jet generated in the uncollapsed state. Moreover, 50% collapse of the IVC causes a shift of the jet away from the IVC wall and towards the center of the vena cava lumen. The area of maximum wall shear stress occurs where the jet impacts the wall and is larger in the collapsed scenarios. Secondary flow is also more complex in the collapsed scenarios. Interestingly, this study demonstrates that a small variation in

  20. Ablación por radiofrecuencia de vía anómala en paciente con agenesia de la vena cava inferior

    Directory of Open Access Journals (Sweden)

    Carlos A. Gómez

    2015-05-01

    Full Text Available Describimos un caso de una paciente de sexo femenino de 55 años de edad a quien se le diagnosticó síndrome de Wolff-Parkinson-White, y al ser llevada al procedimiento de ablación se le encuentra agenesia de la vena cava inferior, con continuidad hacia las cavidades cardiacas derechas a través de la vena ácigos. La realización posterior del procedimiento a través de dicha vena se consideró exitosa, pero ante la recurrencia de las alteraciones electrocardiográficas y nuevos episodios de taquicardia se le realizó nuevo estudio electrofisiológico y ablación por vía yugular interna derecha con éxito. Presentamos además una revisión de la literatura sobre este tópico.

  1. Impact of an inferior vena cava filter retrieval algorithm on filter retrieval rates in a cancer population.

    Science.gov (United States)

    Litwin, Robert J; Huang, Steven Y; Sabir, Sharjeel H; Hoang, Quoc B; Ahrar, Kamran; Ahrar, Judy; Tam, Alda L; Mahvash, Armeen; Ensor, Joe E; Kroll, Michael; Gupta, Sanjay

    2017-09-01

    Our primary purpose was to assess the impact of an inferior vena cava filter retrieval algorithm in a cancer population. Because cancer patients are at persistently elevated risk for development of venous thromboembolism (VTE), our secondary purpose was to assess the incidence of recurrent VTE in patients who underwent filter retrieval. Patients with malignant disease who had retrievable filters placed at a tertiary care cancer hospital from August 2010 to July 2014 were retrospectively studied. A filter retrieval algorithm was established in August 2012. Patients and referring physicians were contacted in the postintervention period when review of the medical record indicated that filter retrieval was clinically appropriate. Patients were classified into preintervention (August 2010-July 2012) and postintervention (August 2012-July 2014) study cohorts. Retrieval rates and clinical pathologic records were reviewed. Filter retrieval was attempted in 34 (17.4%) of 195 patients in the preintervention cohort and 66 (32.8%) of 201 patients in the postintervention cohort (P filter retrieval in the preintervention and postintervention cohorts was 60 days (range, 20-428 days) and 107 days (range, 9-600 days), respectively (P = .16). In the preintervention cohort, 49 of 195 (25.1%) patients were lost to follow-up compared with 24 of 201 (11.9%) patients in the postintervention cohort (P filter placement to death, when available. The overall survival for patients whose filters were retrieved was longer compared with the overall survival for patients whose filters were not retrieved (P filter retrieval, two patients (2.5%) suffered from recurrent VTE (n = 1 nonfatal pulmonary embolism; n = 1 deep venous thrombosis). Both patients were treated with anticoagulation without filter replacement. Inferior vena cava filter retrieval rates can be significantly increased in patients with malignant disease with a low rate (2.5%) of recurrent VTE after filter retrieval

  2. SU-G-IeP4-15: Ultrasound Imaging of Absorbable Inferior Vena Cava Filters for Proper Placement

    Energy Technology Data Exchange (ETDEWEB)

    Mitcham, T; Bouchard, R; Melancon, A; Melancon, M [University of Texas MD Anderson Cancer Center, Houston, TX (United States); Eggers, M [Adient Medical Technologies, Pearland, TX (United States)

    2016-06-15

    Purpose: Inferior vena cava filters (IVCFs) are used in patients with a high risk of pulmonary embolism in situations when the use of blood thinning drugs would be inappropriate. These filters are implanted under x-ray guidance; however, this provides a dose of ionizing radiation to both patient and physician. B-mode ultrasound (US) imaging allows for localization of certain implanted devices without radiation dose concerns. The goal of this study was to investigate the feasibility of imaging the placement of absorbable IVCFs using US imaging to alleviate the dosage concern inherent to fluoroscopy. Methods: A phantom was constructed to mimic a human IVC using tissue-mimicking material with 0.5 dB/cm/MHz acoustic attenuation, while agar inclusions were used to model acoustic mismatch at the venous interface. Absorbable IVCF’s were imaged at 15 cm depth using B-mode US at 2, 3, 5, and 7 MHz transmit frequencies. Then, to determine temporal stability, the IVCF was left in the phantom for 10 weeks; during this time, the IVCF was imaged using the same techniques as above, while the integrity of the filter was analyzed by inspecting for fiber discontinuities. Results: Visualization of the inferior vena cava filter was possible at 5, 7.5, and 15 cm depth at US central frequencies of 2, 3, 5, and 7 MHz. Imaging the IVCF at 5 MHz yielded the clearest images while maintaining acceptable spatial resolution for identifying the IVCF’s, while lower frequencies provided noticeably worse image quality. No obvious degradation was observed over the course of the 10 weeks in a static phantom environment. Conclusion: Biodegradable IVCF localization was possible up to 15 cm in depth using conventional B-mode US in a tissue-mimicking phantom. This leads to the potential for using B-mode US to guide the placement of the IVCF upon deployment by the interventional radiologist. Mitch Eggers is an owner of Adient Medical Technologies. There are no other conflicts of interest to disclose.

  3. Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

    International Nuclear Information System (INIS)

    Zhang, Wen; Yan, Zhiping; Luo, Jianjun; Fang, Zhuting; Wu, Linlin; Liu, QingXin; Qu, Xudong; Liu, Lingxiao; Wang, Jianhua

    2013-01-01

    Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX 2 was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy, and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan–Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 ± 0.12 kg, 57.83 ± 8.68 days, (16.73 ± 5.18 %), (29.47 ± 7.18 %), and 2.03 ± 0.13 kg, 43.67 ± 5.28 days, (63.01 ± 2.01 %), (6.02 ± 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT in rabbit model

  4. Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wen; Yan, Zhiping; Luo, Jianjun; Fang, Zhuting; Wu, Linlin; Liu, QingXin; Qu, Xudong; Liu, Lingxiao; Wang, Jianhua [Fudan University, Department of Interventional Radiology, Zhongshan Hospital (China)

    2013-10-15

    Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX{sub 2} was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy, and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan-Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 {+-} 0.12 kg, 57.83 {+-} 8.68 days, (16.73 {+-} 5.18 %), (29.47 {+-} 7.18 %), and 2.03 {+-} 0.13 kg, 43.67 {+-} 5.28 days, (63.01 {+-} 2.01 %), (6.02 {+-} 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT

  5. Guenther Tulip Filter Retrieval from a Left-sided Inferior Vena Cava

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Kaufman, John A.; Lakin, Paul L.

    2004-01-01

    Optional (retrievable) inferior cava filters (IVC) may have advantages over permanent filters in a certain subset of patients, especially in view of recent concerns about the long-term thrombotic complications of the latter. Retrieval of the Guenther Tulip Filter (GTF), an optional filter, has been reported in a total of 76 patients. We present the first description of GTF retrieval from a left-sided IVC using the right internal jugular approach

  6. The high-risk polytrauma patient and inferior vena cava filter use.

    Science.gov (United States)

    Berber, Onur; Vasireddy, Aswin; Nzeako, Obi; Tavakkolizadeh, Adel

    2017-07-01

    The aim of this study was to assess the impact on practice of vena cava filter insertion guidelines (Eastern Association for the Surgery of Trauma: practice management guidelines). The study was performed at a level 1 trauma centre with data from the 'Trauma Audit and Research Network' cross-referenced to hospital data. A total of 1138 specific 'high-risk' major trauma patients were identified over a 6-year period. The mean age was 46 years (18-102) and the male to female ratio was 3.3:1. The average Injury Severity Score was 23.6 (4-75). The overall DVT rate was 2.6% and the PE rate was 1.8%. A retrievable IVC filter was inserted in 42 cases (3.8%). The filter retrieval rate was 23.8% at a mean of 68.5days (4-107). Only one complication was reported of a breakthrough PE despite filter. Applying the EAST guidelines to this cohort would have suggested filter insertion in 279 (24.6%) cases. The kappa concordance value between observed practice and the 'EAST filter group' was 0.103 (poor). The PE rate in the 'EAST filter group' was 2.2% vs 1.6% in the 'no filter group' (p=0.601, no statistical difference) and the observed odds ratio was 0.814 (95% CI 0.413, 1.602). The EAST guidelines are useful but may be overestimating the need for filter insertion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Renal Sinus Fat Invasion and Tumoral Thrombosis of the Inferior Vena Cava-Renal Vein: Only Confined to Renal Cell Carcinoma

    OpenAIRE

    Turker Acar; Mustafa Harman; Serkan Guneyli; Sait Sen; Nevra Elmas

    2014-01-01

    Epithelioid angiomyolipoma (E-AML), accounting for 8% of renal angiomyolipoma, is usually associated with tuberous sclerosis (TS) and demonstrates aggressive behavior. E-AML is macroscopically seen as a large infiltrative necrotic tumor with occasional extension into renal vein and/or inferior vena cava. However, without history of TS, renal sinus and venous invasion E-AML would be a challenging diagnosis, which may lead radiologists to misinterpret it as a renal cell carcinoma (RCC). In this...

  8. Practice patterns of retrievable inferior vena cava filters and predictors of filter retrieval in patients with pulmonary embolism.

    Science.gov (United States)

    Kang, Jieun; Ko, Heung-Kyu; Shin, Ji Hoon; Ko, Gi-Young; Jo, Kyung-Wook; Huh, Jin Won; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Jae Seung

    2017-12-01

    Retrievable inferior vena cava (IVC) filters are increasingly used in patients with venous thromboembolism (VTE) who have contraindications to anticoagulant therapy. However, previous studies have shown that many retrievable filters are left permanently in patients. This study aimed to identify the common indications for IVC filter insertion, the filter retrieval rate, and the predictive factors for filter retrieval attempts. To this end, a retrospective cohort study was performed at a tertiary care center in South Korea between January 2010 and May 2016. Electronic medical charts were reviewed for patients with pulmonary embolism (PE) who underwent IVC filter insertion. A total of 439 cases were reviewed. The most common indication for filter insertion was a preoperative/procedural aim, followed by extensive iliofemoral deep vein thrombosis (DVT). Retrieval of the IVC filter was attempted in 44.9% of patients. The retrieval success rate was 93.9%. History of cerebral hemorrhage, malignancy, and admission to a nonsurgical department were the significant predictive factors of a lower retrieval attempt rate in multivariate analysis. With the increased use of IVC filters, more issues should be addressed before placing a filter and physicians should attempt to improve the filter retrieval rate.

  9. Are inferior vena cava filters effective for prophylaxis of critical pulmonary embolism in patients with cancer and coexisting venous thromboembolism?

    International Nuclear Information System (INIS)

    Deguchi, Juno; Nagayoshi, Mikiko; Onozuka, Atsuko

    2008-01-01

    Cancer sometimes causes venous thromboembolisms (VTE) including pulmonary embolisms (PE), which impedes aggressive treatment such as chemotherapy. From January 2003 to March 2007, there were 120 hospitalized patients with existing VTE in The University of Tokyo Hospital. Among them we reviewed 39 patients with cancer who required aggressive chemoradiotherapy and examined whether inferior vena cava (IVC) filtration was necessary in addition to ordinary anticoagulant therapy. The clinical stage of cancer was stage I in 7, stage II in 4, stage III in 11, and stage IV in 17. Most were advanced cancer. Of the 39, 9 underwent an IVC filter placement (filter group) and 30 did not (no-filter group). All of them received regular anticoagulant therapy. In the long-term follow up averaging 16.9 months, one patient of the filter group required discontinuation of chemotherapy due to symptomatic PE, but there was no such a case in the no-filter group. Filter-related complications such as IVC occlusion or migration did not occur. Computed tomography showed VTE in the long-term course in 27 out of 39 patients, and suggested increased thrombi in cases of recurrent cancer and those with poor outcome. Seventeen died of cancer but no one died of PE during the study. This study showed that IVC filters offered no beneficial effect for the patients with existing VTE who receive aggressive chemotherapy. (author)

  10. A Retrospective Evaluation of Echocardiograms to Establish Normative Inferior Vena Cava and Aortic Measurements for Children Younger Than 6 Years.

    Science.gov (United States)

    Stenson, Erin K; Punn, Rajesh; Ramsi, Musaab; Kache, Saraswati

    2018-02-26

    The ability to plot the inferior vena cava (IVC) size on a normal curve for pediatric patients may prove beneficial. First, in patients with normal cardiac anatomy who present in shock, assessing IVC size may be valuable for evaluating the degree of dehydration. Second, in children with heart disease, understanding how a child's IVC size compares to normal could be particularly beneficial for patients with right heart disease. We sought to create normal curves for the IVC and aorta in children younger than 6 years. Data were gathered from 347 echocardiograms of healthy children younger than 6 years in a retrospective study at a quaternary care children's hospital. From the subcostal long- and short-axis images, maximum diameters in the transverse and longitudinal views were obtained for both the IVC and the aorta. Both IVC and aortic dimensions increased in a linear fashion and had excellent correlations with the body surface area, body mass, and height (IVC, r = 0.78-0.81; P pediatric patient's hydration status or right heart function in patients with congenital heart disease. © 2018 by the American Institute of Ultrasound in Medicine.

  11. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    International Nuclear Information System (INIS)

    Juszkat, Robert; Pukacki, Fryderyk; Zarzecka, Anna; Kulesza, Jerzy; Majewski, Waclaw

    2009-01-01

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

  12. Technical and financial feasibility of an inferior vena cava filter retrieval program at a level one trauma center.

    Science.gov (United States)

    Charlton-Ouw, Kristofer M; Leake, Samuel S; Sola, Cristina N; Sandhu, Harleen K; Albarado, Rondel; Holcomb, John B; Miller, Charles C; Safi, Hazim J; Azizzadeh, Ali

    2015-01-01

    Considering new guidelines for retrievable inferior vena cava filters (IVCFs), we examine our initial experience after establishing a comprehensive filter removal program in our level 1 trauma center. We evaluated the technical and financial feasibility of this program and barriers to IVCF retrieval, including insurance status and costs, in trauma patients. Trauma patients receiving IVCFs from May 2011 to 2013 were consented and prospectively enrolled in the study program. Retrieval rates were assessed for the years before study initiation. Primary outcome was IVCF retrieval. Hospital financial data for retrieval were examined and univariate analysis performed. Hospital cost-to-charge and payment-to-charge ratios were assessed. Before study initiation from April 2009 to 2011, 66 IVCFs were placed in trauma patients with only 2 retrievals in 2 years. During the study period, 247 trauma patients had IVCF placement of which 111 (45%) were enrolled. The main reason for nonenrollment was lack of referral by the implanting team. Retrieval was attempted in 100 outpatients with success in 85 (85%). Patients enrolled in the program were more likely to have their filters removed (73% vs. 18%; odds ratio, 12.6; 95% confidence interval, 6.6-24.3; P financially feasible without loss to the health care system even in regions with high rates of uninsured. A major barrier to successful filter retrieval was lack of patient referral into the program by implanting physicians. Hospital administration and physician outreach are important determinants of successful IVCF retrieval in trauma patients. Published by Elsevier Inc.

  13. Clinical application of hepatic vein percutaneous transluminal angioplasty and stent after stent placement in inferior vena cava

    International Nuclear Information System (INIS)

    Xu Hao; Zu Maoheng; Gu Yuming; Li Guojun; Zhang Qingqiao; Wei Ning; Xu Wei; Liu Hongtao

    2005-01-01

    Objective: To investigate the feasibility and effect of recanalization of hepatic vein with percutaneous transluminal angioplasty (PTA) and stent after stent placement in inferior vena cava (IVC). Methods: Eleven patients with Budd-Chiari syndrome (BCS)were once performed metal stent placement in IVC at other hospital, but ascites was not subsided in 9 patients after the stent placement and occurred again in 2 patients in 3 months after the procedure. PTA and metal stent placement were used to treat the occlusion of the hepatic vein (HV) via stent in IVC. Results: Recanalization of occlusive HV was successful in all 11 patients, and symptoms disappeared or were obviously improved. The mean blood pressure in HV dropped from pre-operation (45.12 ± 1.57) cm H 2 O (1 cm H 2 O=0.098 kPa) to post-operation (17.53 ± 0.68) cm H 2 O (P<0.01). In a period of 4-30 months (mean: 13.6 months) following-up, no patient reoccurred symptoms. Conclusion: Recanalization of HV via stent in IVC is a feasible and effective method for occlusive HV, but it is difficult. (authors)

  14. Membranous obstruction of inferior vena cava(MOIVC): treatment with percutaneous transluminal angioplasty(PTA) and self expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ki Yeol; Kim, Baek Hyun; Cha, In Ho; Lee, Nam Joon; Kim, Yun Hwan; Kim, Jung Hyuk [College of Medicine, Korea University, Seoul (Korea, Republic of)

    1994-03-15

    Percutaneous transluminal angioplasty(PTA) with a balloon catheter is a standard method of treatment for membranous obstruction of inferior vena cava(MOIVC). But, correct therapeutic approach has not been established for MOIVC patients whose lesion is associated with extensive thrombotic IVC occlusion. We tried to treat MOIVC associated with or without thrombus. We treated 13 cases of MOIVC(associated with thrombus in 7 cases, no thrombus in 6 cases) with PTA, thrombolysis and self-expandable metallic stents. PTA was successful in 8 cases, but failed in 5 cases. The recurred cases were retreated with PTA, but follow-up study revealed recoiling restenosis in 4 cases and intimal hyperplasia in 1 case at previous PTA site which could be overcome with a self-expandable metallic stent. The complication were occurred in 3 cases which were hemothorax, hemopericardium, and hemoperitoneum respectively. However, those were resolved by conservative treatment only. Recanalization and dilatation could be done in MOIVC patients with or without thrombosis for improvement of patient's symptom. Gianturco self-expandable metallic stent is useful in treatment of recurred MOIVC after balloon dilatation and preventing reocclusion of the IVC after PTA.

  15. Failed Retrieval of an Inferior Vena Cava Filter During Pregnancy Because of Filter Tilt: Report of Two Cases

    International Nuclear Information System (INIS)

    McConville, R. M.; Kennedy, P. T.; Collins, A. J.; Ellis, P. K.

    2009-01-01

    Thromboembolic disease during pregnancy is an important cause of obstetric morbidity and mortality. Pregnant patients with venous thromboembolism are usually managed by conventional anticoagulation. However, this must be discontinued during vaginal or caesarian delivery to avoid haemorrhage and to reduce the risk of possible epidural haematoma. Retrievable inferior vena cava filters (IVCFs) offer protection against pulmonary embolism during this high-risk period, when anticoagulation is discontinued, while avoiding potential long-term sequelae of a permanent IVCF. Here we report two patients who presented in the third trimester of pregnancy with floating ileofemoral deep vein thrombosis. Both patients were initially treated with standard anticoagulation; however, shortly before delivery both patients had a retrievable IVCF placed in a suprarenal position. In both patients, retrieval failed at 28 days after insertion because of filter tilt. The timing and mechanism of filter tilt remains uncertain. We believe that a number of factors could have been involved, including change in the anatomic configuration with lateral displacement of the IVCF as a result of the gravid uterus as well as forceful uterine contractions during labour, which modified the shape and diameter of the IVC. We showed that failure to retrieve the IVCF has had considerable implications for the two young patients regarding long-term anticoagulation and have highlighted the need for further clinical trials regarding the safe use of retrievable IVCFs during pregnancy.

  16. Effectiveness of stereotactic body radiotherapy for hepatocellular carcinoma with portal vein and/or inferior vena cava tumor thrombosis.

    Directory of Open Access Journals (Sweden)

    Mian Xi

    Full Text Available BACKGROUND: To report the feasibility, efficacy, and toxicity of stereotactic body radiotherapy (SBRT for the treatment of portal vein tumor thrombosis (PVTT and/or inferior vena cava tumor thrombosis (IVCTT in patients with advanced hepatocellular carcinoma (HCC. MATERIALS AND METHODS: Forty-one patients treated with SBRT using volumetric modulated arc therapy (VMAT for HCC with PVTT/IVCTT between July 2010 and May 2012 were analyzed. Of these, 33 had PVTT and 8 had IVCTT. SBRT was designed to target the tumor thrombosis and deliver a median total dose of 36 Gy (range, 30-48 Gy in six fractions during two weeks. RESULTS: The median follow-up was 10.0 months. At the time of analysis, 15 (36.6% achieved complete response, 16 (39.0% achieved partial response, 7 (17.1% patients were stable, and three (7.3% patients showed progressive disease. No treatment-related Grade 4/5 toxicity was seen within three months after SBRT. One patient had Grade 3 elevation of bilirubin. The one-year overall survival rate was 50.3%, with a median survival of 13.0 months. The only independent predictive factor associated with better survival was response to radiotherapy. CONCLUSIONS: VMAT-based SBRT is a safe and effective treatment option for PVTT/IVCTT in HCC. Prospective randomized controlled trials are warranted to validate the role of SBRT in these patients.

  17. The clinical application of inferior vena cava filters: the essential point is to use it appropriately

    International Nuclear Information System (INIS)

    Yang Zhengqiang; Li Linsun

    2011-01-01

    This paper aims to describe the history and current situation of the clinical application of inferior venal cava (IVC) filters. As there is a possible tendency for physicians to abuse the IVC filters in clinical practice, the authors think that it is necessary now to judge the advantages and disadvantages of the use of IVC filters again and to conscientiously reconsider what kind of patients are suitable for IVC filter implantation. In this article, the proper characteristics that an ideal IVC filter should possess are introduced, the indications for IVC filter implantation are discussed and the complications occurred after IVC filter implantation are analyzed. The authors believe that the retrievable filters will gradually substitute for permanent filters, for this reason, studies concerning IVC retrievable filters will become the hot spots of research in the near future. (authors)

  18. Impact of Physician Education and a Dedicated Inferior Vena Cava Filter Tracking System on Inferior Vena Cava Filter Use and Retrieval Rates Across a Large US Health Care Region.

    Science.gov (United States)

    Wang, Stephen L; Cha, Hsien-Hwa A; Lin, James R; Francis, Bolanos; Elizabeth, Wakley; Martin, Porras; Rajan, Sudhir

    2016-05-01

    To evaluate the effects of physician familiarity with current evidence and guidelines on inferior vena cava (IVC) filter use and the availability of IVC filter tracking infrastructure on retrieval rates. Fourteen continuing medical education-approved in-hospital grand rounds covering evidence-based review of the literature on IVC filter efficacy, patient-centered outcomes, guidelines for IVC filter indications, and complications were performed across a large United States (US) health care region serving more than 3.5 million members. A computer-based IVC filter tracking system was deployed simultaneously. IVC filter use, rates of attempted retrieval, and fulfillment of guidelines for IVC filter indications were retrospectively evaluated at each facility for 12 months before intervention (n = 427) and for 12 months after intervention (n = 347). After education, IVC filter use decreased 18.7%, with a member enrollment-adjusted decrease of 22.2%, despite an increasing IVC filter use trend for 4 years. Reduction in IVC filter use at each facility strongly correlated with physician attendance at grand rounds (r = -0.69; P = .007). Rates of attempted retrieval increased from 38.9% to 54.0% (P = .0006), with similar rates of successful retrieval (82.3% before education and 85.8% after education on first attempt). Improvement in IVC filter retrieval attempts correlated with physician attendance at grand rounds (r = 0.51; P = .051). IVC filter dwell times at first retrieval attempt were similar (10.2 wk before and 10.8 wk after). Physician education dramatically reduced IVC filter use across a large US health care region, and represents a learning opportunity for physicians who request and place them. Education and a novel tracking system improved rates of retrieval for IVC filter devices. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  19. Maintenance of pulmonary vasculature tone by blood derived from the inferior vena cava in a rabbit model of cavopulmonary shunt.

    Science.gov (United States)

    Ikai, Akio; Shirai, Mikiyasu; Nishimura, Kazunobu; Ikeda, Tadashi; Kameyama, Takayuki; Ueyama, Koji; Komeda, Masashi

    2005-01-01

    internal diameter of the resistance pulmonary artery of the atresia group was significantly different from those of the stenosis and sham groups. In the atresia group, the resistance pulmonary arteries did not respond to hypoxia. In contrast, significant constriction (as assessed by percentage change of internal diameter of the resistance pulmonary arteries in the acinar and lobular level arteries) was observed in the pulmonary arteries of the sham and stenosis groups (atresia vs stenosis vs sham 0.4% vs - 19.0% vs - 18.8%, P = .01). In our morphometric study, we observed vasodilation of the resistance pulmonary artery with a thinner medial layer in the atresia group, consistent with the result of microangiography. We developed a cavopulmonary shunt rabbit model in which the inferior vena caval blood was derived from the right ventricle. Hypoxic pulmonary vasoconstriction was maintained in the model with the blood flow from the right ventricle. When the blood flow was not maintained, however, hypoxic pulmonary vasoconstriction disappeared. This phenomenon strongly suggests that a substance in hepatic venous effluent partially regulates the physiological pulmonary vascular function in the rabbit lung.

  20. Predicting inferior vena cava (IVC) filter retrievability using positional parameters: A comparative study of various filter types.

    Science.gov (United States)

    Gotra, A; Doucet, C; Delli Fraine, P; Bessissow, A; Dey, C; Gallix, B; Boucher, L-M; Valenti, D

    2018-05-14

    To compare changes in inferior vena cava (IVC) filter positional parameters from insertion to removal and examine how they affect retrievability amongst various filter types. A total of 447 patients (260 men, 187 women) with a mean age of 55 years (range: 13-91 years) who underwent IVC filter retrieval between 2007-2014 were retrospectively included. Post-insertion and pre-retrieval angiographic studies were assessed for filter tilt, migration, strut wall penetration and retrieval outcomes. ANCOVA and multiple logistic regression models were used to analyze factors affecting retrieval success. Pairwise comparisons between filter types were performed. Of 488 IVC filter retrieval attempts, 94.1% were ultimately successful. The ALN filter had the highest mean absolute value of tilt (5.6 degrees), the Optease filter demonstrated the largest mean migration (-8.0mm) and the Bard G2 filter showed highest mean penetration (5.2mm). Dwell time of 0-90 days (OR, 11.1; P=0.01) or 90-180 days (OR, 2.6; P=0.02), net tilt of 10-15 degrees (OR 8.9; P=0.05), caudal migration of -10 to 0mm (OR, 3.46; P=0.03) and penetration less than 3mm (OR, 2.6; P=0.01) were positive predictors of successful retrievability. Higher odds of successful retrieval were obtained for the Bard G2X, Bard G2 and Cook Celect when compared to the ALN and Cordis Optease filters. Shorter dwell time, lower mean tilt, caudal migration and less caval wall penetration are positive predictors of successful IVC filter retrieval. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  1. Outcomes after inferior vena cava filter placement in cancer patients diagnosed with pulmonary embolism: risk for recurrent venous thromboembolism.

    Science.gov (United States)

    Coombs, Catherine; Kuk, Deborah; Devlin, Sean; Siegelbaum, Robert H; Durack, Jeremy C; Parameswaran, Rekha; Mantha, Simon; Deng, Kathy; Soff, Gerald

    2017-11-01

    Venous thromboembolism (VTE) is a common complication in cancer patients and anticoagulation (AC) remains the standard of care for treatment. Inferior vena cava (IVC) filters may also used to reduce the risk of pulmonary embolism, either alone or in addition to AC. Although widely used, data are limited on the safety and efficacy of IVC filters in cancer patients. We performed a retrospective review of outcomes after IVC filter insertion in a database of 1270 consecutive patients with cancer-associated pulmonary embolism (PE) at our institution between 2008 and 2009. Outcomes measured included rate of all recurrent VTE, recurrent PE, and overall survival within 12 months. 317 (25%) of the 1270 patients with PE had IVC filters placed within 30 days of the index PE event or prior to the index PE in the setting of prior DVT. Patients with IVC filters had markedly lower overall survival (7.3 months) than the non-IVC filter patients (13.2 months). Filter patients also had a lower rate of AC use at time of initial PE. There was a trend towards higher recurrent VTE in patients with IVC filters (11.9%) compared to non-filter patients (7.7%), but this was not significant (p = 0.086). The risk of recurrent PE was similar between the IVC filter cohort (3.5%) and non-filter group (3.5%, p = 0.99). Cancer patients receiving IVC filters had a similar risk of recurrent PE, but a trend towards more overall recurrent VTE. The filter patients had poorer overall survival, which may reflect a poorer cancer prognosis, and had greater contraindication to AC; therefore these patients likely had a higher inherent risk for recurrent VTE. A prospective study would be helpful for further clarification on the partial reduction in the recurrent PE risk by IVC filter placement in cancer patients.

  2. Safety and Efficacy of an Absorbable Filter in the Inferior Vena Cava to Prevent Pulmonary Embolism in Swine.

    Science.gov (United States)

    Huang, Steven Y; Eggers, Mitchell; McArthur, Mark J; Dixon, Katherine A; McWatters, Amanda; Dria, Stephen; Hill, Lori R; Melancon, Marites P; Steele, Joseph R; Wallace, Michael J

    2017-12-01

    Purpose To evaluate the immediate and long-term safety as well as thrombus-capturing efficacy for 5 weeks after implantation of an absorbable inferior vena cava (IVC) filter in a swine model. Materials and Methods This study was approved by the institutional animal care and use committee. Eleven absorbable IVC filters made from polydioxanone suture were deployed via a catheter in the IVC of 11 swine. Filters remained in situ for 2 weeks (n = 2), 5 weeks (n = 2), 12 weeks (n = 2), 24 weeks (n = 2), and 32 weeks (n = 3). Autologous thrombus was administered from below the filter in seven swine from 0 to 35 days after filter placement. Fluoroscopy and computed tomography follow-up was performed after filter deployment from weeks 1-6 (weekly), weeks 7-20 (biweekly), and weeks 21-32 (monthly). The infrarenal IVC, lungs, heart, liver, kidneys, and spleen were harvested at necropsy. Continuous variables were evaluated with a Student t test. Results There was no evidence of IVC thrombosis, device migration, caval penetration, or pulmonary embolism. Gross pathologic analysis showed gradual device resorption until 32 weeks after deployment. Histologic assessment demonstrated neointimal hyperplasia around the IVC filter within 2 weeks after IVC filter deployment with residual microscopic fragments of polydioxanone suture within the caval wall at 32 weeks. Each iatrogenic-administered thrombus was successfully captured by the filter until resorbed (range, 1-4 weeks). Conclusion An absorbable IVC filter can be safely deployed in swine and resorbs gradually over the 32-week testing period. The device is effective for the prevention of pulmonary embolism for at least 5 weeks after placement in swine. © RSNA, 2017.

  3. Outcomes and Direct Costs of Inferior Vena Cava Filter Placement and Retrieval within the IR and Surgical Settings.

    Science.gov (United States)

    Makary, Mina S; Kapke, Jordan; Yildiz, Vedat; Pan, Xueliang; Dowell, Joshua D

    2018-02-01

    To compare the outcomes and costs of inferior vena cava (IVC) filter placement and retrieval in the interventional radiology (IR) and surgical departments at a tertiary-care center. Retrospective review was performed of 142 sequential outpatient IVC filter placements and 244 retrievals performed in the IR suite and operating room (OR) from 2013 to 2016. Patient demographic data, procedural characteristics, outcomes, and direct costs were compared between cohorts. Technical success rates of 100% were achieved for both IR and OR filter placements, and 98% of filters were successfully retrieved by IR means, compared with 83% in the OR (P filter insertions, but IR retrievals required half the fluoroscopy time, with an average of 9 minutes vs 18 minutes in the OR (P = .02). There was no significant difference between cohorts in the incidences of complications for filter retrievals, but more postprocedural complications were observed for OR placements (8%) vs IR placements (1%; P = .05). The most severe complication occurred during an OR filter retrieval, resulting in entanglement of the snare device and conversion to an emergent open filter removal by vascular surgery. Direct costs were approximately 20% higher for OR vs IR IVC filter placements ($2,246 vs $2,671; P = .01). Filter placements are equally successfully performed in IR and OR settings, but OR patients experienced significantly higher postprocedural complication rates and incurred higher costs. In contrast, higher technical success rates and shorter fluoroscopy times were observed for IR filter retrievals compared with those performed in the OR. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  4. Social and Demographic Factors Influencing Inferior Vena Cava Filter Retrieval at a Single Institution in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S. Christian, E-mail: csmith@aemrc.arizona.edu; Shanks, Candace, E-mail: Candace.Shanks@osumc.edu; Guy, Gregory, E-mail: Gregory.Guy@osumc.edu; Yang, Xiangyu, E-mail: Xiangyu.Yang@osumc.edu; Dowell, Joshua D., E-mail: Joshua.Dowell@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States)

    2015-10-15

    PurposeRetrievable inferior vena cava filters (IVCFs) are associated with long-term adverse events that have increased interest in improving filter retrieval rates. Determining the influential patient social and demographic factors affecting IVCF retrieval is important to personalize patient management strategies and attain optimal patient care.Materials and MethodsSeven-hundred and sixty-two patients were retrospectively studied who had a filter placed at our institution between January 2011 and November 2013. Age, gender, race, cancer history, distance to residence from retrieval institution, and insurance status were identified for each patient, and those receiving retrievable IVCFs were further evaluated for retrieval rate and time to retrieval.ResultsOf the 762 filters placed, 133 were permanent filters. Of the 629 retrievable filters placed, 406 met the inclusion criteria and were eligible for retrieval. Results revealed patients with Medicare were less likely to have their filters retrieved (p = 0.031). Older age was also associated with a lower likelihood of retrieval (p < 0.001) as was living further from the medical center (p = 0.027). Patients who were white and had Medicare were more likely than similarly insured black patients to have their filters retrieved (p = 0.024).ConclusionsThe retrieval rate of IVCFs was most influenced by insurance status, distance from the medical center, and age. Race was statistically significant only when combined with insurance status. The results of this study suggest that these patient groups may need closer follow-up in order to obtain optimal IVCF retrieval rates.

  5. [Bedside implantation of a new temporary vena cava inferior filter : German results from the European ANGEL registry].

    Science.gov (United States)

    Baumann, S; Becher, T; Giannakopoulos, K; Jabbour, C; Fastner, C; El-Battrawy, I; Ansari, U; Lossnitzer, D; Behnes, M; Alonso, A; Kirschning, T; Dissmann, R; Kueck, O; Stern, D; Michels, G; Borggrefe, M; Akin, I

    2018-04-01

    Pulmonary embolism (PE) is a frequently occurring complication in critically ill patients, and the simultaneous occurrence of PE and life-threatening bleeding is a therapeutic dilemma. Inferior vena cava filters (IVCF) may represent an important therapeutic alternative in these cases. The Angel® catheter (Bio2 Medical Inc., San Antonio, TX, USA) is a novel IVCF that provides temporary protection from PE and is implanted at bedside without fluoroscopy. The European Angel® Catheter Registry is an observational, multicenter study. In our German substudy, we investigated patients from three German hospitals and four intensive care units, who underwent Angel® catheter implantation between February 2016 and December 2016. A total of 23 critically ill patients (68 ± 9 years, 43% male) were included. The main indication for implantation was a high risk for or an established PE, combined with contraindications for prophylactic or therapeutic anticoagulation due to either an increased risk of bleeding (81%) or active bleeding (13%). The Angel® catheter was successfully inserted in all patients at bedside. No PE occurred in patients with an indwelling Angel® catheter. Clots with a diameter larger the 20 mm, indicating clot migration, were detected in 5% of the patients by cavography before filter retrieval. Filter retrieval was uneventful in all of our cases, while filter dislocation occurred in 3% of the patients. The German data from the multicenter European Angel® Catheter Registry show that the Angel® catheter is a safe and effective approach for critically ill patients with a high risk for the development of PE or an established PE, when an anticoagulation therapy is contraindicated.

  6. Prophylactic Placement of an Inferior Vena Cava Filter During Aspiration Thrombectomy for Acute Deep Venous Thrombosis of the Lower Extremity.

    Science.gov (United States)

    Kwon, Se Hwan; Park, So Hyun; Oh, Joo Hyeong; Song, Myung Gyu; Seo, Tae-Seok

    2016-05-01

    To evaluate the effect of an inferior vena cava (IVC) filter during aspiration thrombectomy for acute deep vein thrombosis (DVT) in the lower extremity. From July 2004 to December 2013, a retrospective analysis of 106 patients with acute DVT was performed. All patients received an IVC filter and were treated initially with aspiration thrombectomy. Among the 106 patients, DVT extension into the IVC was noted in 27 but was not evident in 79. We evaluated the presence of trapped thrombi in the filters after the procedure. The sizes of the trapped thrombi were classified into 2 grades based on the ratio of the maximum transverse length of the trapped thrombus to the diameter of the IVC (Grades I [≤ 50%] and II [> 50%]). A trapped thrombus in the filter was detected in 46 (43%) of 106 patients on final venograms. The sizes of the trapped thrombi were grade I in 12 (26.1%) patients and grade II in 34 (73.9%). Among the 27 patients with DVT extension into the IVC, 20 (74.1%) showed a trapped thrombus in the filter, 75% (15 of 20) of which were grade II. Among the 79 patients without DVT extension into the IVC, 26 (32.9%) showed a trapped thrombus in the IVC filter, 73% (19 of 26) of which were grade II. Thrombus migration occurred frequently during aspiration thrombectomy of patients with acute DVT in the lower extremity. However, further studies are needed to establish a standard protocol for the prophylactic placement of an IVC filter during aspiration thrombectomy. © The Author(s) 2016.

  7. Efficacy of Lower-Extremity Venous Thrombolysis in the Setting of Congenital Absence or Atresia of the Inferior Vena Cava

    International Nuclear Information System (INIS)

    Ganguli, Suvranu; Kalva, Sanjeeva; Oklu, Rahmi; Walker, T. Gregory; Datta, Neil; Grabowski, Eric F.; Wicky, Stephan

    2012-01-01

    Purpose: A rare but described risk factor for deep venous thrombosis (DVT), predominately in the young, is congenital agenesis or atresia of the inferior vena cava (IVC). The optimal management for DVT in this subset of patients is unknown. We evaluated the efficacy of pharmacomechanical catheter-directed thrombolysis (PCDT) followed by systemic anticoagulation in the treatment of acute lower-extremity DVT in the setting of congenital IVC agenesis or atresia. Materials and Methods: Between November of 2005 and May of 2010, six patients (three women [average age 21 years]) were referred to our department with acute lower-extremity DVT and subsequently found to have IVC agenesis or atresia on magnetic resonance imaging. A standardized technique for PCDT (the Angiojet Rheolytic Thrombectomy System followed by the EKOS Microsonic Accelerated Thrombolysis System) was used for all subjects. Successful thrombolysis was followed by systemic heparinization with transition to Coumadin or low molecular-weight heparin and compression stockings. Subjects were followed-up at 1, 3, and then every 6 months after the procedure with clinical assessment and bilateral lower-extremity venous ultrasound. Results: All PCDT procedures were technically successful. No venous stenting or angioplasty was performed. The average thrombolysis time was 28.6 h (range 12–72). Two patients experienced heparin-induced thrombocytopenia, and one patient developed a self-limited knee hemarthrosis, No patients were lost to follow-up. The average length of follow-up was 25.8 ± 20.2 months (range 3.8–54.8). No incidence of recurrent DVT was identified. There were no manifestations of postthrombotic syndrome. Conclusions: PCDT followed by systemic anticoagulation and the use of compression stockings appears to be safe and effective in relatively long-term follow-up treatment of patients who present with acute DVT and IVC agenesis or atresia.

  8. Combination of Transarterial Chemoembolization and Three-Dimensional Conformal Radiotherapy for Hepatocellular Carcinoma With Inferior Vena Cava Tumor Thrombus

    International Nuclear Information System (INIS)

    Koo, Ja Eun; Kim, Jong Hoon; Lim, Young-Suk

    2010-01-01

    Purpose: To evaluate the effects of transarterial chemoembolization (TACE) and three-dimensional conformal radiotherapy (CRT) in patients with hepatocellular carcinoma (HCC) and inferior vena cava tumor thrombus (IVCTT). Methods and Materials: A total of 42 consecutive patients who underwent TACE and CRT (TACE+CRT group) for the treatment of HCC with IVCTT were prospectively enrolled from July 2004 to October 2006. As historical controls, 29 HCC patients with IVCTT who received TACE alone (TACE group) between July 2003 and June 2004 were included. CRT was designed to target only the IVCTT and to deliver a median total dose of 45 Gy (range, 28-50 Gy). Results: Most baseline characteristics of the two groups were similar (p > 0.05). The response and progression-free rates of IVCTT were significantly higher in the TACE+CRT group than in the TACE group (42.9% and 71.4% vs. 13.8% and 37.9%, respectively; p < 0.01 for both rates). Overall, patient survival was significantly higher in the TACE+CRT group than in the TACE group (p < 0.01), with a median survival time of 11.7 months and 4.7 months, respectively. Treatment with TACE+CRT (hazard ratio [HR] = 0.38; 95% confidence interval [CI], 0.20-0.71), progression of IVCTT (HR = 4.05; 95% CI, 2.00-8.21), Child-Pugh class B (HR = 3.44; 95% CI, 1.79-6.61), and portal vein invasion (HR = 2.31; 95% CI, 1.19-4.50) were identified as independent predictors of mortality by multivariable analysis. Conclusions: The combination of TACE and CRT is more effective in the control of IVCTT associated with HCC and improves patient survival compared with TACE alone.

  9. Inferior vena cava calibre on paediatric trauma CT may be a useful predictor for the development of shock

    International Nuclear Information System (INIS)

    Barber, J.L.; Touska, P.; Negus, A.S.

    2016-01-01

    Aim: To investigate whether inferior vena cava (IVC) calibre on paediatric trauma computed tomography (CT) can help anticipate outcomes in children. Materials and methods: The imaging and clinical records of 52 paediatric trauma admissions to the level 1 major trauma centre at St George's Hospital, London, UK, were retrospectively reviewed. The IVC dimensions, evidence of significant haemorrhage on CT, and the presence of components of the classical hypoperfusion complex, such as bowel and adrenal hyperenhancement, were recorded. Clinical data included observations at the time of admission and for the subsequent 48-hour period where available, blood gas results, length of stay, and mortality. Results: There was a significant relationship between IVC dimensions in this cohort and the development of shock during the 24-hour admission period. IVC dimensions did not, however, reflect the haemodynamic status at the time of admission, and were not predictive of a longer hospital stay. There were no mortalities among the cases. A weak correlation was also seen with serum lactate, a finding that has also been seen in adults, but is of uncertain clinical significance. Conclusions: IVC calibre was found to be a more useful predictor of shock than heart rate or blood pressure, and may, therefore, prove to be a useful predictor of impending haemodynamic instability in children as it is in adults. Although the study was carried out at a busy unit, the numbers are acknowledged to be small and a larger study would be needed to validate these findings and identify whether there is any variation in the CT appearances between different age groups. - Highlights: • Haemodynamic shock in children is a late and ominous sign. • The IVC was significantly flatter in children who developed shock after major trauma. • IVC flatness on CT was a better predictor of shock than clinical parameters.

  10. Effect of antithrombotic agents on the patency of PTFE-Covered stents in the inferior vena cava: An experimental study

    International Nuclear Information System (INIS)

    Makutani, Shiro; Kichikawa, Kimihiko; Uchida, Hideo; Maeda, Munehiro; Konishi, Noboru; Hiasa, Yoshio; Yoshikawa, Tomohiro; Kimura, Yukio

    1999-01-01

    Purpose: To evaluate the efficacy of antithrombotic agents in the prevention of stenosis of polytetrafluororethylene (PTFE)-covered stents in the venous system.Methods: Spiral Z stents covered with PTFE (PTFE-covered stents) were placed in the inferior vena cava (IVC) of 34 dogs. Nineteen dogs, used as a control group, were sacrificed at 2, 4, and 12 weeks. Fifteen dogs, previously given antithrombotic agents [cilostazol (n=5), warfarin potassium (n=5), cilostazol plus warfarin potassium (n=5)] were sacrificed at 4 weeks, and then examined angiographically and histopathologically. The effect of the antithrombotic agents was compared between groups.Results: The patency rate of the antithrombotic agent group was 93% (14/15), which was higher than the control group rate of 63% (12/19). The mean stenosis rate of the patent stent at both ends and at the midportion was lower at 4 weeks in the antithrombotic agent group than in the control group. In particular, the mean stenosis rate in the cilostazol plus warfarin potassium group was significantly lower than the control group (Tukey's test, p < 0.05). The mean neointimal thickness of the patent stent at both ends and at the midportion was thinner at 4 weeks in the antithrombotic agent group than in the control group. In particular, the thickness of the neointima in the cilostazol plus warfarin potassium group was significantly decreased when compared with the control group (Tukey's test p < 0.05). At 4 weeks, endothelialization in the antithrombotic agent group tended to be almost identical to that in the control group.Conclusion: The present study suggests that administration of an antithrombotic agent is an effective way of preventing the stenosis induced by a neointimal thickening of PTFE-covered stents in the venous system.

  11. Social and Demographic Factors Influencing Inferior Vena Cava Filter Retrieval at a Single Institution in the United States

    International Nuclear Information System (INIS)

    Smith, S. Christian; Shanks, Candace; Guy, Gregory; Yang, Xiangyu; Dowell, Joshua D.

    2015-01-01

    PurposeRetrievable inferior vena cava filters (IVCFs) are associated with long-term adverse events that have increased interest in improving filter retrieval rates. Determining the influential patient social and demographic factors affecting IVCF retrieval is important to personalize patient management strategies and attain optimal patient care.Materials and MethodsSeven-hundred and sixty-two patients were retrospectively studied who had a filter placed at our institution between January 2011 and November 2013. Age, gender, race, cancer history, distance to residence from retrieval institution, and insurance status were identified for each patient, and those receiving retrievable IVCFs were further evaluated for retrieval rate and time to retrieval.ResultsOf the 762 filters placed, 133 were permanent filters. Of the 629 retrievable filters placed, 406 met the inclusion criteria and were eligible for retrieval. Results revealed patients with Medicare were less likely to have their filters retrieved (p = 0.031). Older age was also associated with a lower likelihood of retrieval (p < 0.001) as was living further from the medical center (p = 0.027). Patients who were white and had Medicare were more likely than similarly insured black patients to have their filters retrieved (p = 0.024).ConclusionsThe retrieval rate of IVCFs was most influenced by insurance status, distance from the medical center, and age. Race was statistically significant only when combined with insurance status. The results of this study suggest that these patient groups may need closer follow-up in order to obtain optimal IVCF retrieval rates

  12. Efficacy and Safety of Endovascular Intervention for the Management of Primary Entire-Inferior Vena Cava Occlusion

    International Nuclear Information System (INIS)

    Zhang, Qingqiao; Huang, Qianxin; Shen, Bin; Sun, Jingmin; Wang, Xiaolong; Liu, Hongtao

    2015-01-01

    PurposeThis study was designed to investigate the safety and efficacy of endovascular intervention for the treatment of primary entire-inferior vena cava (IVC) occlusion.MethodsEndovascular interventions were performed in six patients for the treatment of primary entire-IVC occlusion. IVC and hepatic venography were performed via the jugular and femoral veins. Balloon angioplasty was used to revascularize the hepatic vein and IVC and a stent was placed in the IVC to maintain patency. Postoperative color Doppler ultrasonography was performed at 1, 3, 6, and 12 months, and then annually, to monitor the patency of the hepatic vein and IVC.ResultsThe IVC and one or two hepatic veins were successfully revascularized in five patients. Revascularization was successful in the right and left hepatic veins in one patient; however, IVC patency could not be established in this patient. Eleven Z-type, self-expanding stents were placed into the IVCs of five patients (three stents in two patients, two stents in two patients, and one stent in one patient). There were no instances of postoperative bleeding or mortality. Follow-up was conducted for 18–90 months (42.8 ± 26.5 months). None of the five patients suffered restenosis of the IVC or hepatic veins. However, there was one of the six cases of right hepatic vein restenosis at 18 months postprocedure that was revascularized after a second balloon dilatation.ConclusionsEndovascular intervention is safe and efficacious for the treatment of primary entire-IVC occlusion

  13. Mechanism for the tilting of Geunther Tulip inferior vena cava filter inserted via femoral vein: an experimental study in vitro

    International Nuclear Information System (INIS)

    Xiao Liang; Shen Jing; Huang Desheng; Xu Ke

    2011-01-01

    Objective: To clarify the mechanism causing the tilting of Geunther Tulip inferior Vena Cava filter (GTF) which is inserted via femoral vein access by means of the experiment in vitro. Methods: The caval model was established by placing one 25 mm × 10 cm Dacron graft and two 10 mm × 20 cm Dacron grafts into a transparent bifurcate glass tube. The study consisted of two groups: right straight group (G RS ) (n=100) and left straight group (G LS ) (n=100). The distance (D CH ) between the caval right wall and the hook was measured. The degree of tilting (DT) was classified into 5 grades and the data were recorded. Before and after the GTF was released, the angle (A CM1,2 ) between the axis of IVC and the metal mount, the distance (D CM1,2 ) between the caval right wall and the metal mount, the angle (A CF ) between the axis of IVC and the axis of the filter and the diameter of IVC (D IVC ) were measured separately. Results: The degree of GTF tilting in each group revealed a divergent tendency. In Group RS, the apex of the filter tended to be grade Ⅲ compared that in Group LS (59% vs 36%, P=0.003). The differences in most variables between G RS and G LS were considered as statistical significance. Significant positive correlation existed between A CM1 and A CF , A CM1 -A CM2 and D CH1 -D CH2 in each group, respectively, while significant negative association was also existed between D CH1 and A CF in each group. Conclusion: The tilting angle of GTF filter axis before it is released is a major cause of the occurrence of femoral GTF filter tilting. (authors)

  14. Therapeutic effect and prognostic analysis of intensity-modulated radiotherapy for primary hepatocellular carcinoma with portal vein and/or inferior vena cava tumor thrombus

    Directory of Open Access Journals (Sweden)

    HUANG Long

    2015-06-01

    Full Text Available ObjectiveTo determine the efficacy and prognostic factors of intensity-modulated radiotherapy (IMRT for primary hepatocellular carcinoma (HCC with portal vein and/or inferior vena cava tumor thrombus. MethodsTwenty-three HCC patients with portal vein and/or inferior vena cava tumor thrombus received IMRT with an 8 MV linear accelerator at the Cancer Center of General Hospital of Armed Police Forces, Anhui Medical University, from April 2008 to August 2011. A single dose of 3 to 6 Gy was delivered at five fractions per week, with a total dose of 56 to 96 Gy and a median dose of 60 Gy. Survival time was recorded, and adverse reactions were evaluated. Survival rate calculation and survival analysis were performed using the Kaplan-Meier method. Comparison of categorical between two groups was made by chi-square test. ResultsOne patient did not complete radiotherapy due to upper gastrointestinal bleeding. Of 22 patients who completed IMRT, 4 achieved complete remission and 10 achieved partial remission, with an overall response rate of 63.7%. Our analysis showed that the type of tumor thrombus and tumor size were associated with tumor response rate and were significant prognostic factors (P<0.05. The median survival time was 13.4 months. The 1-, 2-, and 3-year survival rates were 59%, 27%, and 18%, respectively. The 22 patients who completed radiotherapy did not experience acute radiation injury or late adverse outcomes such as radiation-induced liver disease. ConclusionThis study suggests IMRT is a safe and effective treatment option for HCC patients with portal vein and/or inferior vena cava tumor thrombus.

  15. Can the Right Kidney be Salvaged in the Surgical Management of Leiomyosarcoma of the Inferior Vena Cava—a Rare Case Report

    OpenAIRE

    Chakrabarti, Suvadip; Agarwal, Deepak; Desai, Sanjay M.; Mehta, Dharmendra Y.

    2015-01-01

    Primary leiomyosarcoma is rare malignant tumour arising from the smooth muscles and can appear at any site where smooth muscle is present. It is more common in the peripheral vessels and has predilection for the female sex. We here report a rare case of leiomyosarcoma involving the segment I & II of inferior vena cava with extension into the renal veins in a 70 year old male patient. Midline transperitoneal approach was taken to excise the tumour along with the vessel wall with anastomosis be...

  16. Renal Sinus Fat Invasion and Tumoral Thrombosis of the Inferior Vena Cava-Renal Vein: Only Confined to Renal Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Turker Acar

    2014-01-01

    Full Text Available Epithelioid angiomyolipoma (E-AML, accounting for 8% of renal angiomyolipoma, is usually associated with tuberous sclerosis (TS and demonstrates aggressive behavior. E-AML is macroscopically seen as a large infiltrative necrotic tumor with occasional extension into renal vein and/or inferior vena cava. However, without history of TS, renal sinus and venous invasion E-AML would be a challenging diagnosis, which may lead radiologists to misinterpret it as a renal cell carcinoma (RCC. In this case presentation, we aimed to report cross-sectional imaging findings of two cases diagnosed as E-AML and pathological correlation of these aforementioned masses mimicking RCC.

  17. Renal sinus fat invasion and tumoral thrombosis of the inferior vena cava-renal vein: only confined to renal cell carcinoma.

    Science.gov (United States)

    Acar, Turker; Harman, Mustafa; Guneyli, Serkan; Sen, Sait; Elmas, Nevra

    2014-01-01

    Epithelioid angiomyolipoma (E-AML), accounting for 8% of renal angiomyolipoma, is usually associated with tuberous sclerosis (TS) and demonstrates aggressive behavior. E-AML is macroscopically seen as a large infiltrative necrotic tumor with occasional extension into renal vein and/or inferior vena cava. However, without history of TS, renal sinus and venous invasion E-AML would be a challenging diagnosis, which may lead radiologists to misinterpret it as a renal cell carcinoma (RCC). In this case presentation, we aimed to report cross-sectional imaging findings of two cases diagnosed as E-AML and pathological correlation of these aforementioned masses mimicking RCC.

  18. Leiomyosarcoma of inferior vena cava involving bilateral renal veins: Surgical challenges and reconstruction with upfront saphenous vein interposition graft for left renal vein outflow

    Directory of Open Access Journals (Sweden)

    Rishi Nayyar

    2010-01-01

    Full Text Available Leiomyosarcoma of inferior vena cava (IVC involving bilateral renal veins presents a surgical challenge. Herein, we report the successful management of two such cases using restoration of left renal venous outflow by saphenous vein interposition graft as first step of surgery. Then radical resection of tumor and right kidney was done. IVC was lastly reconstructed using Gore-Tex graft. This report highlights the surgical challenges to ensure radical resection. Furthermore, the importance of restoring left renal outflow in presence of concomitant right nephrectomy is discussed. Both the patients were disease free at six months with no loss of left renal glomerular filtration rate.

  19. Inverted Nutcracker Syndrome: A Case of Persistent Hematuria and Pain in the Presence of a Left-Sided Inferior Vena Cava

    Directory of Open Access Journals (Sweden)

    Obi Ekwenna

    2011-01-01

    Full Text Available Nutcracker syndrome is described as the symptomatic compression of left renal vein between the aorta and the superior mesenteric artery, resulting in outflow congestion of the left kidney. We present the case of a 51-year-old male with a left-sided inferior vena cava, resulting in compression of the right renal vein by the superior mesenteric artery. Secondary to this anatomic anomaly, the patient experienced a many-year history of flank pain and intermittent gross hematuria. We have termed this unusual anatomic finding and its associated symptoms as the “inverted nutcracker syndrome”, and describe its successful management with nephrectomy and autotransplantation.

  20. Large cell non-Hodgkin's lymphoma masquerading as renal carcinoma with inferior vena cava thrombosis: a case report

    Directory of Open Access Journals (Sweden)

    Weissman Alan

    2011-06-01

    Full Text Available Abstract Introduction Many cancers are associated with inferior vena cava (IVC obstruction, but very few cancers have the ability to propagate within the lumen of the renal vein or the IVC. Renal cell carcinoma is the most common of these cancers. Renal cancer with IVC extension has a high rate of recurrence and a low five year survival rate. Case presentation A 62-year-old Caucasian woman previously in good health developed the sudden onset of severe reflux symptoms and right-sided abdominal pain that radiated around the right flank. A subsequent ultrasound and CT scan revealed a right upper pole renal mass with invasion of the right adrenal gland, liver, left renal vein and IVC. This appeared to be consistent with stage III renal cancer with IVC extension. Metastatic nodules were believed to be present in the right pericardial region; the superficial anterior abdominal wall; the left perirenal, abdominal and pelvic regions; and the left adrenal gland. The pattern of these metastases, as well as the invasion of the liver by the tumor, was thought to be atypical of renal cancer. A needle biopsy of a superficial abdominal wall mass revealed a surprising finding: The malignant cells were diagnostic of large-cell, B-cell non-Hodgkin's lymphoma. The lymphoma responded dramatically to systemic chemotherapy, which avoided the need for nephrectomy. Conclusion Lymphomas only rarely progress via intraluminal vascular extension. We have been able to identify only one other case report of renal lymphoma with renal vein and IVC extension. While renal cancer would have been treated with radical nephrectomy and tumor embolectomy, large-cell B-cell lymphomas are treated primarily with chemotherapy, and nephrectomy would have been detrimental. It is important to remember that, rarely, other types of cancer arise from the kidney which are not derived from the renal tubular epithelium. These may be suspected if an atypical pattern of metastases or unusual

  1. Endovascular Removal of Fractured Inferior Vena Cava Filter Fragments: 5-Year Registry Data with Prospective Outcomes on Retained Fragments.

    Science.gov (United States)

    Kesselman, Andrew J; Hoang, Nam Sao; Sheu, Alexander Y; Kuo, William T

    2018-06-01

    To evaluate the safety and efficacy of attempted percutaneous filter fragment removal during retrieval of fractured inferior vena cava (IVC) filters and to report outcomes associated with retained filter fragments. Over a 5-year period, 82 consecutive patients presenting with a fractured IVC filter were prospectively enrolled into an institutional review board-approved registry. There were 27 men and 55 women (mean, 47 y; range, 19-85 y). After main filter removal, percutaneous removal of fragments was attempted if they were deemed intravascular and accessible on preprocedural computed tomography (CT), cone-beam CT, and/or intravascular ultrasound; distal pulmonary artery (PA) fragments were left alone. A total of 185 fragments were identified (81 IVC, 33 PA, 16 cardiac, 2 hepatic vein, 1 renal vein, 1 aorta, 51 retroperitoneal). Mean filter dwell time was 2,183 days (range, 59-9,936 d). Eighty-seven of 185 fragments (47%) were deemed amenable to attempted removal: 65 IVC, 11 PA, 8 cardiac, 2 hepatic, and 1 aortic. Primary safety outcomes were major procedure-related complications. Fragment removal was successful in 78 of 87 cases (89.7%; 95% confidence interval [CI], 81.3-95.2). There were 6 minor complications with no consequence (6.9%; 95% CI, 2.6-14.4) involving intraprocedural fragment embolization and 1 major complication (1.1%; 95% CI, 0.0-6.2), a cardiac tamponade that was successfully treated. The complication rate from attempted cardiac fragment removal was 12.5% (1 of 8; 95% CI, 0.3-52.7). Among patients with retained cardiopulmonary fragments (n = 19), 81% remained asymptomatic during long-term clinical follow-up of 845 days (range, 386-2,071 d). Percutaneous removal of filter fragments from the IVC and proximal PAs is safe and effective overall, but attempted intracardiac fragment removal carries a higher risk of complication. Most residual filter fragments not amenable to percutaneous removal remain asymptomatic and may be monitored clinically

  2. Incidence and Outcomes of Inferior Vena Cava Filter Thrombus during Catheter-directed Thrombolysis for Proximal Deep Venous Thrombosis.

    Science.gov (United States)

    Jiang, Jianguang; Tu, Jianfei; Jia, Zhongzhi; Chen, Jiezhong; Cao, Haitao; Meng, Qingli; Fuller, Tyler A; Tian, Feng

    2017-01-01

    The aim of the study was to retrospectively evaluate the incidence and outcomes of inferior vena cava (IVC) filter thrombus during catheter-directed thrombolysis (CDT) for acute proximal deep venous thrombosis (DVT). From October 2006 to June 2015, patients diagnosed with acute proximal DVT and received CDT after a retrievable IVC filter was placed were included. The incidence, treatment, and outcomes of IVC filter thrombus during CDT were recorded and analyzed. A total of 189 patients (91 women, 98 men; mean age, 57.6 ± 9.8 years; range, 24-85 years) were included in this study. Among the 189 cases, the DVTs involved popliteal iliofemoral veins in 54 patients, iliofemoral veins in 113 patients, and iliac veins in 22 patients, of which 18 patients had thrombus extended into the IVC. Of the 189 patients, a total of 8 (4.2%, 8 of 189) patients were identified with IVC filter thrombus during CDT. The IVC filter thrombus was detected on a median of 2 days (range, 2-4 days) of CDT therapy, including small-size (n = 6) and large-size (n = 2) filter thrombus. Of the 8 patients, CDTs were performed with a mean 7.6 ± 1.1 days (range, 6-11 days) after the presence of symptoms for the treatment of proximal DVT, and all the IVC filter thrombi were lysed during CDT for the proximal DVT. All the IVC filters were removed successfully with a mean of 12.8 ± 0.93 days from placement. There were no procedure- or thrombolysis-related major complications, and no symptomatic pulmonary embolism breakthrough was seen in any of the patients after the filter placement. IVC filter thrombus during CDT for the acute proximal DVT is uncommon, and all of them did not need any additional treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. The 6-F nitinol TrapEase inferior vena cava filter: results of a prospective multicenter trial.

    Science.gov (United States)

    Rousseau, H; Perreault, P; Otal, P; Stockx, L; Golzarian, J; Oliva, V; Reynaud, P; Raat, F; Szatmari, F; Santoro, G; Emanuelli, G; Nonent, M; Hoogeveen, Y

    2001-03-01

    The authors report the first results of a new 6-F symmetrically designed permanent nitinol inferior vena cava (IVC) filter, the Cordis TrapEase, evaluated in a multicenter prospective study with 6-months of follow-up. A total of 65 patients (29 men, 36 women) who ranged in age from 37 to 96 years (mean age, 68 years) and who were at high risk of pulmonary embolism (PE) were enrolled in 12 centers in Europe and Canada. The study was approved by the institutional review boards at all centers. Study objectives were to evaluate filter effectiveness, filter stability, and caval occlusion. Indications for filter placement were deep vein thrombosis with recurrent thromboembolism and/or free-floating thrombus with contraindication to anticoagulation in 37 patients, and complications in achieving adequate anticoagulation in 28 patients. Follow-up included clinical examination, plain film, Doppler ultrasound, CT scan, and nuclear medicine. The analysis of the data revealed a technical success of 95.4% (three filter-system related implantations not at the intended site, no events of filter tilting) and a clinical success of 100% at 6 months (no cases of symptomatic PE), the study primary endpoint. There were no cases (0%) of filter migration, insertion site thrombosis, filter fracture, or vessel wall perforation. During the study period, there were two cases of filter thrombosis: one case of early symptomatic thrombosis that was successfully treated in the hospital, and one case of nonsymptomatic filter thrombosis detected at 1-month follow-up, with spontaneous recanalization at 3 months. In the latter patient, some residual thrombus was still detected at 6 months. Of the study population of 65 patients, there were 23 deaths. These deaths were not related to the device or the implantation procedure but to the underlying disease process. This study demonstrates the new nitinol permanent IVC filter to be a safe and an effective device, with a low overall complication rate, for

  4. Placement and retrieval of a Guenther tulip filter in patients with a free floating thrombus in inferior vena cava

    International Nuclear Information System (INIS)

    Seong, Min Hyun; Kim, Young Hwan; Lee, Sang Kwon; Choi, Jin Soo; Kim, Mi Jeong; Koo, Ja Hyun; Kim, Hyoung Tae; Cho, Won Hyun; Seong, Nak Kwan

    2005-01-01

    We wanted to assess the technical feasibility and clinical efficacy of the placement and retrieval of a Guenther Tulip filter for the prevention of fatal pulmonary embolism during the management of patients with a free floating thrombus in their inferior vena ca va (IVC). Six patients having a free floating thrombus in their IVC (three patients with an isolated free floating thrombus in the IVC that resulted from immobilization due to traumatic liver injury or cerebral infarction, two patients with coexisting deep vein thrombosis in the left lower extremity that was caused by May-Thurner syndrome, and one patient with coexisting deep vein thrombosis in the right lower extremity that was due to nephrotic syndrome and immobilization after hip joint replacement) underwent placement and retrieval of a Guenther Tulip filter. The placement of the filter was performed through the right internal jugular vein to prevent the risk of detachment of the thrombus during the procedure. Retrieval of filter was performed after the free floating thrombus of the IVC had disappeared on follow-up CT because of anticoagulation therapy, aspiration thrombectomy or catheter directed Urokinase thrombolysis. The Guenther Tulip filter was successfully placed in the IVC in all six patients and it was retrieved after the management of the free floating thrombus. The mean duration of the placement of the filter was 11 days (range:7-25 days). Two patients underwent placement of an iliac vein stent for the management of May-Thurner syndrome. Detachment of the free floating thrombus in the IVC and the subsequent thrombus entrapment in the filter were documented during aspiration thrombectomy or Urokinase thrombolysis in four patients. Recurrent thrombus didn't occur during the follow-up period (range:3-20 months) in five of the six patients. In one patient, a recurrent thrombus due to the discontinuance of anticoagulation therapy was identified at the filter detachment site of the IVC on the follow

  5. Role of presurgical targeted molecular therapy in renal cell carcinoma with an inferior vena cava tumor thrombus

    Directory of Open Access Journals (Sweden)

    Peng C

    2018-04-01

    Full Text Available Cheng Peng,1,* Liangyou Gu,1,* Lei Wang,2 Qingbo Huang,1 Baojun Wang,1 Gang Guo,1 Yang Fan,1 Yu Gao,1 Xin Ma,1 Xu Zhang1 1Department of Urology, State Key Laboratory of Kidney Diseases, Chinese PLA General Hospital, Chinese PLA Medical Academy, Beijing, People’s Republic of China; 2Department of Urology, Chinese PLA 534 Hospital, Luoyang, People’s Republic of China *These authors contributed equally to this work Purpose: The clinical benefit of targeted molecular therapy (TMT in renal cell carcinoma (RCC with an inferior vena cava (IVC tumor thrombus remains controversial. The aim of this study was to investigate the effects of presurgical TMT on the heights and levels of IVC thrombi, and to assess its impact on surgical strategy. Patients and methods: We retrospectively reviewed data from 18 patients with RCC involving IVC tumor thrombi who were treated at our hospital with presurgical TMT followed by an IVC thrombectomy. The changes in heights and levels of the IVC thrombi were compared using computed tomography or magnetic resonance imaging. Clinicopathological factors were also evaluated to assess their association with TMT efficacy. Results: The tumor thrombus levels before TMT were stage I in 1 patient (5.6%, II in 12 patients (66.7%, III in 4 patients (22.2%, and IV in 1 patient (5.6%. After a median of two treatment cycles (range: 1–3, the thrombus height decreased measurably in 11 patients (61.1% with an average shrinkage of 17.7%. The thrombus height remained stable in five patients (27.8% and was enlarged in two (11.1%. Downstaging of the thrombus level occurred in four patients (22.2%; the surgical strategy was modified in three patients (16.7% to avoid cardiopulmonary bypass and complicated liver mobilization under robot-assisted laparoscopy. Furthermore, a higher neutrophil count tended to be associated with a worse clinical TMT-associated outcome (P=0.056. Conclusion: Our data suggest a limited influence of presurgical TMT

  6. Vena cava filters in cancer patients: experience with 50 patients Filtros de veia cava inferior em pacientes com câncer: experiência em 50 casos

    Directory of Open Access Journals (Sweden)

    Antonio Eduardo Zerati

    2005-10-01

    Full Text Available OBJECTIVE: To study the immediate and late results obtained from the implantation of vena cava filters in cancer patients with deep vein thrombosis concomitant with neoplasia. METHODS: This was a retrospective evaluation of 50 patients with an association of cancer and deep venous thrombosis who underwent interruption of the inferior vena cava and the insertion of permanent vena cava filters. The indications for the procedure, filter implantation technique, early and late complications related to the operation, and the clinical evolution were evaluated. RESULTS: The most frequent indication for filter implantation was the contraindication for full anticoagulant treatment (80%. The femoral vein was the preferred access route (86% of the patients. There were no complications related to the surgical procedure. During the follow-up, the following complications were observed: 1 episode of nonfatal pulmonary thromboembolism, 2 cases of occlusion of the inferior vena cava, and 1 case of thrombus retained in the device. Twenty patients (40% died due to progression of the neoplasm. CONCLUSIONS: Interruption of the inferior cava vein using an endoluminal filter is a procedure with a low rate of complications. It is a safe and efficient measure for preventing pulmonary embolism in cancer patients who have deep vein thrombosis of the lower limbs.OBJETIVO: Estudar os resultados imediatos e tardios obtidos com a implantação de filtros de veia cava inferior em pacientes com trombose venosa profunda concomitante a neoplasia. MÉTODOS: Avaliamos retrospectivamente 50 pacientes com câncer e trombose venosa profunda associada submetidos a interrupção de veia cava inferior com filtros intraluminais definitivos. Foram estudados aspectos referentes à indicação do procedimento, à técnica de implante dos dispositivos, complicações precoces e tardias relacionadas à operação e à evolução dos pacientes. RESULTADOS: A indicação mais freqüente para o

  7. Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults

    Directory of Open Access Journals (Sweden)

    Kaja Durajska

    2014-09-01

    Full Text Available The assessment of the body fluid status is one the most challenging tasks in clinical practice. Although there are many methods to assess the body fluid status of patients, none of them is fully satisfactory in contemporary medical sciences. In the article below, we compare the results of measurements performed by experienced and inexperienced examiners based on the inferior vena cava/aorta diameter index in a sonographic hydration assessment. The study enrolled 50 young students at the age of 19–26 (the median age was 22.95 including 27 women and 23 men. The volunteers were examined in the supine position with GE Logiq 7 system and a convex transducer with the frequency of 2–5 MHz. The measurements were performed in the longitudinal and transverse planes by two inexperienced examiners – the authors of this paper, following a four-hour training conducted by an experienced sonographer. The longitudinal values of the inferior vena cava/aorta diameter index obtained in this study were similar to those found in the literature. The reference value for the inferior vena cava/aorta index determined by Kosiak et al., which constituted 1.2 ± 2 SD, for SD = 0.17, was similar to the values obtained by the authors of this paper which equaled 1.2286 ± 2 SD, for SD = 0.2. The article presented below proves that measuring the inferior vena cava/aorta diameter index is not a complex examination and it may be performed by physicians with no sonographic experience. Furthermore, the paper demonstrates that the inferior vena cava/aorta diameter index measured in the transverse plane is similar to the inferior vena cava/aorta diameter index determined in the longitudinal plane. Thus, both measurements may be used interchangeably to assess the hydration status of patients.

  8. Management of acute lower extremity deep venous thrombosis in a patient with duplicated inferior vena cava and contraindication to anticoagulation: case and review of the literature.

    Science.gov (United States)

    Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael

    2018-06-04

    Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon.We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Is the inferior vena cava diameter measured by bedside ultrasonography valuable in estimating the intravascular volume in patients with septic shock?

    Directory of Open Access Journals (Sweden)

    Mortaza Talebi Doluie

    2016-07-01

    Full Text Available Introduction:Resuscitation should be initiated immediately in shock. Early goal-directed therapy is an established algorithm for the resuscitation in septic shock. The first step is to maintain cardiac preload. Central venous pressure (CVP plays an important role in goal-directed therapy. Central venous catheterization is invasive and time-consuming in emergency conditions. There are some alternative and noninvasive methods for estimating the intravascular volume such as measuring the inferior vena cava (IVC diameter by ultrasonography. Methods: We searched PubMed, Google scholar, and Scopus databases with keywords (central venous pressure OR venous pressure OR CVP AND (ultrasonography OR sonography AND (sepsis OR septic shock AND (inferior vena cava OR IVC.Result: The search resulted in 2550 articles. The articles were appraised regarding the relevance, type of article, and statistical methods. Finally, 12 articles were selected. The number of patients was between 30 and 83 cases (mean age=57-67 years, intubated and non-intubated in each study. The IVC diameter was measured in respiratory cycle by bedside ultrasonography in longitudinal subxiphoid view and caval index was calculated, then they were compared with the CVP measured by central venous catheter.Discussion: CVP is an indicator of intravascular fluid status and right heart function. CVP measurement is an invasive method and of course with some complications. The IVC is the biggest vein of venous system with low-pressure; expansion of the vein reflects intravascular volume.Conclusion: It seems that IVC diameter measured by ultrasonography could be used as an alternative method for the determination of CVP in the emergency or critical patients.

  10. The application of GxA8xB9nther Tulip retrievable inferior vena cava filter in interventional treatment for acute deep venous thrombosis of lower extremity

    International Nuclear Information System (INIS)

    Xiao Liang; Xu Ke; Shen Jing; Li Haiwei; Tong Jiajie; Zhang Xitong

    2010-01-01

    Objective: To discuss the therapeutic efficacy and manipulation skill of Gunther Tulip retrievable inferior vena cava filter in interventional treatment for acute deep venous thrombosis of lower extremity. Methods: From September 2007 to April 2008, a total of 36 patients with acute deep venous thrombosis of lower extremity were treated in our hospital. The time of the onset of disease ranged from 1 day to 12 days. The precipitation causes included prolonged lying in bed due to surgery or bone fracture (n = 18) and postpartum (n = 5), while no obvious precipitation causes could be found in 13 patients. Pulmonary embolism was coexisted in 12 cases. Clinically, the affected limb was swelling and painful, the skin was cyan-purple or pale in color with higher skin temperature. The circumferential length of the affected thigh was 3-10 cm longer than that of normal side. Patients with coexisted pulmonary embolism had the clinical presentation of dyspnea, chest pain, hemoptysis, etc. Gunther Tulip retrievable inferior vena cava filter was implanted via femoral venous access or via right internal jugular venous access, which was followed by intravenous transcatheter thrombolysis. Vascular ultrasonography and angiography were performed 45-75 days after the treatment to confirm that there was no fresh or free thrombus in the veins of lower limb or in the pulmonary arteries. When it was confirmed, Gunther Tulip retrievable inferior vena cava filter was taken out via right internal jugular venous access, which was followed by inferior venacavography. After the procedure anticoagulation and antibiotic medication were employed for 3-5 days. A follow-up for 4-10 months was made. Results: A total of 36 Gunther Tulip retrievable inferior vena cava filters were successfully implanted by one procedure, the average time cost for the filter delivery was 1.5 minutes (0.5-5 minutes). During the delivery procedure, the amplitude of elastic displacement of filter was less than 2 mm. One

  11. Gunther Tulip Inferior Vena Cava Filter Placement During Treatment for Deep Venous Thrombosis of the Lower Extremity

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Iida, Shigeharu; Hirota, Tatsuya; Nishimura, Tsunehiko

    2005-01-01

    Purpose. To evaluate the efficacy and safety of Gunther tulip retrievable vena cava filter (GTF) implantation to prevent pulmonary embolism during intravenously administered thrombolytic and anticoagulation therapy and interventional radiological therapy for occlusive or nonocclusive deep venous thrombosis (DVT) of the lower extremity. Methods. We evaluated placement of 55 GTFs in 42 patients with lower extremity DVT who had undergone various treatments including those utilizing techniques of interventional radiology. Results. Worsening of pulmonary embolism in patients with existing pulmonary embolism or in those without pulmonary embolism at the time of GTF insertion was avoided in all patients. All attempts at implantation of the GTF were safely accomplished. Perforation and migration experienced by one patient was the only complication. Mean period of treatment for DVT under protection from pulmonary embolism by the GTF was 12.7 ± 8.3 days (mean ± SD, range 4-37 days). We attempted retrieval of GTFs in 18 patients in whom the venous thrombus had disappeared after therapy, and retrieval in one of these 18 cases failed. GTFs were left in the vena cava in 24 patients for permanent use when the DVT was refractory to treatment. Conclusion. The ability of the GTF to protect against pulmonary embolism during treatment of DVT was demonstrated. Safety in both placement and retrieval was clarified. Because replacement with a permanent filter was not required, use of the GTF was convenient when further protection from complicated pulmonary embolism was necessary

  12. Drenagem anômala de veia pulmonar inferior direita em veia cava inferior associada a apêndice hepático intracardíaco Anomalous drainage of the right inferior pulmonary vein into the inferior vena cava associated to intrathoracic hepatic appendix

    Directory of Open Access Journals (Sweden)

    Carlos R Moraes

    1988-08-01

    Full Text Available Descreve-se o caso de uma paciente de 61 anos de idade, com drenagem anômala de veia pulmonar inferior direita em veia cava inferior, associada a apêndice hepático intratorácico, herniado através de fenda no diafragma. A correção cirúrgica foi realizada por anastomose direta da veia anômala com o átrio esquerdo, pela redução do apêndice hepático para a cavidade abdominal e, finalmente, pelo fechamento do defeito diafragmático. O pós-operatório decorreu sem qualquer complicação. Os autores chamam a atenção para a raridade do caso.The authors present a case of a 61-year-old woman with anomalous drainage of the right inferior pulmonary vein into the inferior vena cava associated to an intrathoracic hepatic appendix herniated through a diaphragmatic defect. Surgical correction was obtained by direct anastomosis of the anomalous vein to the left atrium, reduction of the hepatic appendix to the abdominal cavity and closure of the diphragmatic defect. The postoperative course was unevenftul. The rarity of this condition is stressed.

  13. Percutaneous Transhepatic Cholangiography

    African Journals Online (AJOL)

    1974-03-30

    Mar 30, 1974 ... Percutaneous transhepatic cholangiography can play a major role in expediting the early diagnosis of surgically correctable jaundice. The need for this is emphasised by the fact that in a group of 46 patients the delay between the onset of jaundice and diagnosis ranged from 20 to 90 days. Transhepatic ...

  14. Percutaneous transhepatic biliary drainage

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Hong, Seong Mo; Han, Man Chung

    1982-01-01

    Percutaneous transhepatic biliary drainage was successfully made 20 times on 17 patients of obstructive jaundice for recent 1 year since June 1981 at Department of Radiology in Seoul National University Hospital. The causes of obstructive jaundice was CBD Ca in 13 cases, metastasis in 2 cases, pancreatic cancer in 1 case and CBD stone in 1 case. Percutaneous transhepatic biliary drainage is a relatively ease, safe and effective method which can be done after PTC by radiologist. It is expected that percutaneous transhepatic biliary drainage should be done as an essential procedure for transient permanent palliation of obstructive jaundice

  15. Real-time flow - determination of vena cava inferior on two different levels via 'RACE' pulse sequence in MR

    International Nuclear Information System (INIS)

    Helzel, M.V.; Mueller, E.

    1993-01-01

    A new and simple parameter for quantiative evaluation of liver perfusion is outlined: Post-sinusoidal quantitative measurement of the entire liver venous flow: This is a result of the differences in evaluated flow volumes at two different levels in the inferior V.cava. The first level is the height of diaphragm, and the second is situated just cranial of the renal vessels. Normal values obtained from a group of healthy volunteers are presented. A gradient-echo pulse sequence called RACE, enabling flow measurements in real-time, is outlined. (orig.) [de

  16. Detection and characterization of Budd-Chiari syndrome with inferior vena cava obstruction: Comparison of fixed and flexible delayed scan time of computed tomography venography.

    Science.gov (United States)

    Zhou, Peng-Li; Wu, Gang; Han, Xin-Wei; Bi, Yong-Hua; Zhang, Wen-Guang; Wu, Zheng-Yang

    2017-06-01

    To compare the results of computed tomography venography (CTV) with a fixed and a flexible delayed scan time for Budd-Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. A total of 209 consecutive BCS patients with IVC obstruction underwent either a CTV with a fixed delayed scan time of 180s (n=87) or a flexible delayed scan time for good image quality according to IVC blood flow in color Doppler ultrasonography (n=122). The IVC blood flow velocity was measured using a color Doppler ultrasound prior to CT scan. Image quality was classified as either good, moderate, or poor. Image quality, surrounding structures and the morphology of the IVC obstruction were compared between the two groups using a χ 2 -test or paired or unpaired t-tests as appropriate. Inter-observer agreement was assessed using Kappa statistics. There was no significant difference in IVC blood flow velocity between the two groups. Overall image quality, surrounding structures and IVC obstruction morphology delineation on the flexible delayed scan time of CTV images were rated better relative to those obtained by fixed delayed scan time of CTV images (ptime of CTV. There were no significant differences in Kappa statistics between Group A and Group B. The flexible delayed scan time of CTV was associated with better detection and more reliable characterization of BCS with IVC obstruction compared to a fixed delayed scan time. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Vascular mechanotransduction data in a rodent model of diabetes: Pressure-induced regulation of SHP2 and associated signaling in the rat inferior vena cava

    Directory of Open Access Journals (Sweden)

    Kevin M. Rice

    2017-12-01

    Full Text Available The effect of diabetes on vascular mechano-transductive response is of great concern. Given the higher rate of vein graft failures associated with diabetes, understanding the multiple cellular and molecular events associated with vascular remodeling is of vital importance. This article represents data related to a study published in Cardiovascular Diabetology [1] (Rice et al., 2006 and Open Journal of Endocrine and Metabolic Diseases [2] (Rice et al., 2015 evaluating the effect of pressurization on rat inferior venae cavae (IVC. Provided within this articles is information related to the method and processing of raw data related to our prior publish work and Data in Brief articles [3,4] (Rice et al., 2017, as well as the evaluation of alternation in SHP-2 signaling and associated proteins in response to mechanical force. IVC from lean and obese animals were exposed to a 30 min perfusion of 120 mm Hg pressure and evaluated for changes in expression of SHP2, BCL-3, BCL-XL, HSP 27, HSP 70, and PI3K p85, along with the phosphorylation of SHP-2 (Tyr 542.

  18. Estimation and tracking of AP-diameter of the inferior vena cava in ultrasound images using a novel active circle algorithm.

    Science.gov (United States)

    Karami, Ebrahim; Shehata, Mohamed S; Smith, Andrew

    2018-05-04

    Medical research suggests that the anterior-posterior (AP)-diameter of the inferior vena cava (IVC) and its associated temporal variation as imaged by bedside ultrasound is useful in guiding fluid resuscitation of the critically-ill patient. Unfortunately, indistinct edges and gaps in vessel walls are frequently present which impede accurate estimation of the IVC AP-diameter for both human operators and segmentation algorithms. The majority of research involving use of the IVC to guide fluid resuscitation involves manual measurement of the maximum and minimum AP-diameter as it varies over time. This effort proposes using a time-varying circle fitted inside the typically ellipsoid IVC as an efficient, consistent and novel approach to tracking and approximating the AP-diameter even in the context of poor image quality. In this active-circle algorithm, a novel evolution functional is proposed and shown to be a useful tool for ultrasound image processing. The proposed algorithm is compared with an expert manual measurement, and state-of-the-art relevant algorithms. It is shown that the algorithm outperforms other techniques and performs very close to manual measurement. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. The internal anatomy of the inferior vena cava with specific emphasis on the entrance of the renal, gonadal and lumbar veins.

    Science.gov (United States)

    Bubb, Kathleen; du Plessis, Maira; Hage, Robert; Tubbs, R Shane; Loukas, Marios

    2016-01-01

    Major tributaries such as the renal and adrenal veins have been studied extensively; however, tributaries of the infra-renal segment of the inferior vena cava (IVC) have not been given much attention. Accurate knowledge of the anatomy of these veins is necessary for improved efficacy of surgical interventions in the retroperitoneum. The aim of this study therefore was to provide a comprehensive picture of the internal anatomy of the tributaries of the infra-renal segment of the IVC. Dissection of the posterior abdominal wall was performed on 30 formalin-fixed cadavers. Endoscopic study was carried out followed by a midline venotomy on the anterior wall of the isolated IVC, the location and orientation of its tributaries and their ostia were observed and measurements taken. The results showed that while there was great variation in the drainage pattern of the lumbar veins, most lumbar veins had ostia located between L2 and L3 vertebrae irrespective of the location of renal and gonadal tributaries. Valves were found in 81.81 % of gonadal veins, in 56.60 % of all lumbar veins and discrete ostial valves in 14.81 % of renal veins. The location of the tributaries of the IVC was correlated with the vertebral levels. Empirical data regarding their ostio-valvular complexes were established, which put into question widely accepted concept of valveless tributaries. Our results may implicate surgical procedures in and around the retroperitoneal region.

  20. Thrombolysis for treating deep venous thrombosis by high-dose urokinase: the usefulness of preventive placement of inferior vena cava filter

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; He Shicheng; Qiu Haibo; Fang Wen; Zhu Guangyu; Deng Gang

    2002-01-01

    Objective: To investigate the feasibility and efficacy of high-dose urokinase thrombolysis for treating lower limb deep venous thrombosis (DVT) after inferior vena cava (IVC) filter placement. Methods: Thirteen patients of venographically proved DVT underwent preventive IVC filter placement for thrombolysis by high-dose urokinase. Antegrade infusion of high-dose urokinase was performed via the dorsalis pedis vein of the involved lower limb. The total dose of urokinase was 9 000 000 ∼ 16 000 000 units, and the procedure of thrombolysis was performed in ICU ward where the patients were closely monitored clinically and laboratorially. Results: A total of 13 IVC filters were successfully deployed without disposition and migration. The therapeutic effects were divided into four scales as follows: complete disappearance of the venous thrombosis and clinically asymptomatic (n = 2); remarkable recovery characterized by markedly improved clinical symptoms and venographically proved patent lumen in which the diameter was larger than 70% (n = 9); effective treatment indicating improved symptoms to some degrees and venographically proved patent lumen in which the diameter was smaller than 70% ( n = 2); and ineffective treatment (n = 0). No pulmonary embolism and hemorrhage occurred during the procedure of thrombolysis. Conclusion: High-dose urokinase for treating DVT is safe and effective after preventive placement of IVC filter

  1. Outcomes of inferior vena cava filter insertion in patients with lower extremity deep vein thrombosis for prevention of pulmonary thromboembolism: A single center retrospective analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Jin; Kim, Jae Kyu; Yim, Nam Yeol; Kim, Hyoung Ook [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Kang, Yang Jun [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2017-07-15

    To evaluate the mid- and long-term outcomes of inferior vena cava (IVC) filter insertion in patients with underlying deep vein thrombosis for prevention of pulmonary thromboembolism, based on a single center experience. A total of 166 IVC filter insertion procedures in 160 patients, between February 2004 and December 2014, were retrospectively reviewed. Severity of deep vein thrombosis, indwelling time of the IVC filter, retrieval rate, and complication rate depending on the type of IVC filter were analyzed based on the patients' radiologic findings and medical records. IVC filter insertion procedures were successfully performed in all patients. Among the 99 attempts at filter retrieval, 91 trials succeeded (91.9%, 91/99) and 8 trials failed. Indwelling time of the IVC filter showed a positive correlation with failure of filter retrieval (p = 0.01). There was no procedure-related complication after all IVC filter insertion procedures. Eight delayed complications (5.0%, 8/160 patients with IVC filter insertion) were observed [caval thrombosis below the IVC filter (n = 7) and IVC penetration (n = 1)]. Günther Tulip filter was associated with a significant incidence of complication (p = 0.036). IVC filter insertion in patients with lower extremity deep vein thrombosis for prevention of pulmonary thromboembolism can be regarded as a safe treatment modality with an acceptable complication rate.

  2. Deep Venous Thrombosis of the Leg, Associated with Agenesis of the Infrarenal Inferior Vena Cava and Hypoplastic Left Kidney (KILT Syndrome in a 14-Year-Old Child

    Directory of Open Access Journals (Sweden)

    Sakshi Bami

    2015-01-01

    Full Text Available Agenesis of the inferior vena cava (IVC is a rare anomaly which can be identified as incidental finding or can be associated with iliofemoral vein thrombosis. IVC agenesis has a known association with renal anomalies which are mainly confined to the right kidney. We describe a case of a 14-year-old male who presented with left leg swelling and pain. Ultrasonography confirmed the presence of left leg deep vein thrombosis (DVT. No underlying hematologic risk factors were identified. A CT scan was obtained which demonstrated absent infrarenal IVC and extensive thrombosis in the left deep venous system and development of collateral venous flow into the azygous/hemiazygous system, with extension of thrombus into paraspinal collaterals. An additional finding in the patient was an atrophic left kidney and stenosis of an accessory left renal artery. Agenesis of the IVC should be considered in a young patient presenting with lower extremity DVT, especially in patients with no risk factors for thrombosis. As agenesis of the IVC cannot be corrected, one should be aware that there is a lifelong risk of lower extremity DVT.

  3. Outcomes of inferior vena cava filter insertion in patients with lower extremity deep vein thrombosis for prevention of pulmonary thromboembolism: A single center retrospective analysis

    International Nuclear Information System (INIS)

    Park, Byung Jin; Kim, Jae Kyu; Yim, Nam Yeol; Kim, Hyoung Ook; Kang, Yang Jun

    2017-01-01

    To evaluate the mid- and long-term outcomes of inferior vena cava (IVC) filter insertion in patients with underlying deep vein thrombosis for prevention of pulmonary thromboembolism, based on a single center experience. A total of 166 IVC filter insertion procedures in 160 patients, between February 2004 and December 2014, were retrospectively reviewed. Severity of deep vein thrombosis, indwelling time of the IVC filter, retrieval rate, and complication rate depending on the type of IVC filter were analyzed based on the patients' radiologic findings and medical records. IVC filter insertion procedures were successfully performed in all patients. Among the 99 attempts at filter retrieval, 91 trials succeeded (91.9%, 91/99) and 8 trials failed. Indwelling time of the IVC filter showed a positive correlation with failure of filter retrieval (p = 0.01). There was no procedure-related complication after all IVC filter insertion procedures. Eight delayed complications (5.0%, 8/160 patients with IVC filter insertion) were observed [caval thrombosis below the IVC filter (n = 7) and IVC penetration (n = 1)]. Günther Tulip filter was associated with a significant incidence of complication (p = 0.036). IVC filter insertion in patients with lower extremity deep vein thrombosis for prevention of pulmonary thromboembolism can be regarded as a safe treatment modality with an acceptable complication rate

  4. Complications of Celect, Günther tulip, and Greenfield inferior vena cava filters on CT follow-up: a single-institution experience.

    Science.gov (United States)

    McLoney, Eric D; Krishnasamy, Venkatesh P; Castle, Jordan C; Yang, Xiangyu; Guy, Gregory

    2013-11-01

    To evaluate and compare the rates of complications on follow-up computed tomography (CT) studies of patients with Celect, Günther Tulip, and Greenfield inferior vena cava (IVC) filters. Retrospective review of CT studies obtained 0-1,987 days after infrarenal placement of an IVC filter identified 255 Celect, 160 Tulip, and 50 Greenfield filters. Follow-up CT studies were independently evaluated by two observers for IVC perforation, contact with adjacent organs, and filter fracture. Multivariate analysis was performed to identify factors associated with higher rates of IVC perforation, including age, IVC diameter, sex, and history of malignancy. IVC perforation was observed in 126 of 255 Celect filters (49%) with a mean follow-up of 277 days, 69 of 160 Tulip filters (43%) with a mean follow-up of 437 days, and one of 50 Greenfield filters (2%) with a mean follow-up of 286 days. A significantly higher IVC perforation rate was observed in women (45.5%) compared with men (30.8%; P = .002) and in patients with a history of malignancy (43.7%) compared with patients with no history of malignancy (29.9%; P Tulip filters (0.6%), and none of 50 Greenfield filters. No significant difference was observed in IVC perforation rate between Celect and Tulip filters. Greenfield filters had a significantly lower rate of IVC perforation than Celect and Tulip filters. Higher IVC perforation rates were observed in women and patients with a history of malignancy. © SIR, 2013.

  5. PO-38 - Young women with breast cancer and inferior vena cava thrombosis. Which is the best therapeutic option? And for how long?

    Science.gov (United States)

    Vilaseca, A B; Capmany, C L; Sabsay, F

    2016-04-01

    Thromboembolic disease (TED) is frequent, and, thromboembolic events are the second cause of death in active cancer patients Today we have knowledge of a lot of risk and predictor factors of thrombosis in cancer, although some mechanisms underlying this increased thromboembolic risk, still remains unclear. Knowing that cancer is today curable, we want to remark that not only old people but also young should be investigated about their personal burden of thromboembolic disease to improve prognosis, and at the same time remark the need to establish different therapeutic strategies in each stage of the disease to prevent or treat TED. We present the case of a young 28 old, female, with breast nodule and axillaries lymphadenopathies, highly suspicious of breast cancer. She has an acute Inferior Vena Cava Thrombosis in her Scan Tomography with a 40% occlusion clinically asymptomatic. Personal history: 2008 splenectomy by a refractory autoimmune hemolytic anemia Directed Coombs Positive (DC) to corticosteroids, 2010 hypothyroidism, 2011 anti lupus antibodies(LA) during traditional pre surgical coagulation test, that persist along time. Family history positive for breast cancer, mother and grandmother and negative for thromboembolic disease In this scenario we decide to put her in low molecular weight heparin 1mg/kg bid a day until we have the oncology diagnosis and then re evaluate our therapeutic anticoagulant decision. After breast cancer diagnosis with the axillaries biopsy she continued with LMWH at full doses to perform the surgery and complete treatment. The diagnosis after surgery was high grade intraductal carcinoma N1 Pos of 21. She performs chemotherapy with cyclophosphamide, doxorubicin and taxol and then radiotherapy. She has been controlled with doppler ultrasonography every three months, at month six shows vena cava recanalization. When she finished radiotherapy we stop HBPM one day and reevaluated for LA that persist positive. At this time we decided to

  6. Estudo da resposta tissular à endoprótese recoberta de jugular bovina em veia cava inferior de suínos Bovine jugular covered stent-graft implanted in swine inferior vena cava - a study of tissue response

    Directory of Open Access Journals (Sweden)

    Cristina Ribeiro Riguetti Pinto

    2006-06-01

    Full Text Available OBJETIVO: Avaliar a resposta tissular a uma endoprótese, com cobertura biológica heteróloga, implantada em veia cava inferior de suínos. MÉTODO: Desenvolvemos uma endoprótese auto-expansível, revestida com um segmento de jugular bovina, conservada por processo L-hydro e suturada em um stent de aço inoxidável 316L. O dispositivo introdutor utilizado foi a bainha de liberação da endoprótese aórtica Taheri-Leonhardt (Flórida, EUA. Foram implantadas endopróteses em 10 suínos, todas na veia cava infra-renal. Os animais foram submetidos à flebografia peroperatória. À necropsia, após 2 meses, cada endoprótese foi retirada em bloco e analisada macroscopicamente, visando a avaliação da perviedade, aderência aos tecidos vizinhos e incorporação à parede venosa; e, histopatologicamente, visando a resposta histológica ao enxerto. RESULTADOS: Na análise macroscópica, todas as endopróteses encontravam-se pérvias e totalmente incorporadas à parede venosa, porém seis apresentavam trabeculações grosseiras no seu interior e quatro algum grau de fibrose perivascular. Três animais desenvolveram linfocele, uma retroperitoneal e as outras na parede abdominal. No estudo histopatológico, observamos reação inflamatória granulomatosa tipo corpo estranho em todos os casos, sendo predominante na camada média (80%. CONCLUSÃO: O modelo estudado apresentou baixa trombogenicidade, corroborando com a eficácia do meio de conservação e material escolhidos; porém, baixa biocompatibilidade, provavelmente pelo obstáculo imunológico dos xenoenxertos e resposta tissular exagerada do território venoso.OBJECTIVE: To evaluate tissue response to a bovine jugular vein covered stent when implanted in the swine inferior vena cava. METHOD: We developed a self-expanding stent, using a segment of L-hydro conserved bovine jugular vein, which was trimmed and sutured to a 316L stainless steel stent. We used the Taheri-Leonhardt delivery system for

  7. Percutaneous transhepatic sphincterotomy

    International Nuclear Information System (INIS)

    Gandin, G.; Zanon, E.; Righi, D.; Fonio, P.; Ferrari, A.; Recchia, S.

    1990-01-01

    The authors describe the techique employed for percutaneous trans-hepatic sphincterotomy as performed on 3 patients with common bile duct (CBD) stones. In all patients, previous endoscopic attempt had failed for anatomical reasons (Billroth II gastric resection or partial gastric resection with brown anastomosis), and the ampulla could not be correctly incannulated with the sphincterotome. In all aptients endoscopy was useful to check the position of the diethermic loop inserted percutaneously. Conplete and immediate success was obtained in all 3 cases. No major complications occurred during transhepatic treatment. To date, 1 recurrence has been observed, and the patient has been retreated with bilioplasty. All patients were followed after 5-6 months with US, plain X-rays of the abdomen and blood tests (γGt, alkaline phosphatase, and bilirubinemia). The authors suggest that percutaneous transhepatic sphincterotomy be employed electively in patients with biliary tree diseases in case the endoscopic approach failes

  8. Creation of an iOS and Android Mobile Application for Inferior Vena Cava (IVC) Filters: A Powerful Tool to Optimize Care of Patients with IVC Filters.

    Science.gov (United States)

    Deso, Steven E; Idakoji, Ibrahim A; Muelly, Michael C; Kuo, William T

    2016-06-01

    Owing to a myriad of inferior vena cava (IVC) filter types and their potential complications, rapid and correct identification may be challenging when encountered on routine imaging. The authors aimed to develop an interactive mobile application that allows recognition of all IVC filters and related complications, to optimize the care of patients with indwelling IVC filters. The FDA Premarket Notification Database was queried from 1980 to 2014 to identify all IVC filter types in the United States. An electronic search was then performed on MEDLINE and the FDA MAUDE database to identify all reported complications associated with each device. High-resolution photos were taken of each filter type and corresponding computed tomographic and fluoroscopic images were obtained from an institutional review board-approved IVC filter registry. A wireframe and storyboard were created, and software was developed using HTML5/CSS compliant code. The software was deployed using PhoneGap (Adobe, San Jose, CA), and the prototype was tested and refined. Twenty-three IVC filter types were identified for inclusion. Safety data from FDA MAUDE and 72 relevant peer-reviewed studies were acquired, and complication rates for each filter type were highlighted in the application. Digital photos, fluoroscopic images, and CT DICOM files were seamlessly incorporated. All data were succinctly organized electronically, and the software was successfully deployed into Android (Google, Mountain View, CA) and iOS (Apple, Cupertino, CA) platforms. A powerful electronic mobile application was successfully created to allow rapid identification of all IVC filter types and related complications. This application may be used to optimize the care of patients with IVC filters.

  9. Outcome of Resection and Chemotherapy versus Chemotherapy Alone for Retroperitoneal Recurrence of Testicular Cancer Involving the Inferior Vena Cava: A Retrospective Cohort Study of 22 Consecutive Patients.

    Science.gov (United States)

    Illuminati, Giulio; Calio, Francesco G; Angelici, Alberto M; Pizzardi, Giulia; Pasqua, Rocco; Masci, Federica; Vietri, Francesco

    2016-07-01

    Optimal treatment strategy for retroperitoneal recurrence of testicular cancer involving the inferior vena cava (IVC) is uncertain. The purpose of this study was to validate the hypothesis that surgical resection, en-bloc with the involved segment of IVC and its subsequent reconstruction followed by chemotherapy, would yield better oncologic results than chemotherapy alone. Two consecutive series of patients with retroperitoneal recurrence of testicular cancer involving the IVC, treated with surgical resection plus chemotherapy (group A, n=14) or chemotherapy alone (group B, n=8) were retrospectively reviewed. The mean duration of follow-up was was 65 months (range=8-184). Operative mortality and morbidity in group A, response to chemotherapy in group B, disease-specific survival and quality adjusted life-years (QALY) for both groups, were primary end-points of the study. Postoperative mortality and morbidity (group A) were, respectively, nil and 14%. In group B, two patients (25%) fully responded to chemotherapy and remained free from disease progression. Disease-specific survival at 3 and 5 years was 81% and 54% in group A and 36% in group B both at 3 and 5 years, respectively (p=0.02). QALY was 3.92 in group A and 0.77 for both 3 and 5 years in group B, respectively, (p=0.031). En bloc resection of retroperitoneal recurrence of testicular tumors invading the IVC, followed by chemotherapy, allows a better survival rate compared to chemotherapy alone. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  10. Bed-side inferior vena cava diameter and mean arterial pressure predict long-term mortality in hospitalized patients with heart failure: 36 months of follow-up.

    Science.gov (United States)

    Torres, Daniele; Cuttitta, Francesco; Paterna, Salvatore; Garofano, Alessandro; Conti, Giosafat; Pinto, Antonio; Parrinello, Gaspare

    2016-03-01

    In discharged patients with heart failure (HF), diverse conditions can intervene to worsen outcome. We would investigate whether such factors present on hospital admission can affect long-term mortality in subjects hospitalized for acute HF. One hundred twenty-three consecutive patients hospitalized for acute HF (mean age 74.8 years; 57% female) were recruited and followed for 36 months after hospitalization. At multivariate Cox model, only inferior vena cava (IVC) diameter and mean arterial pressure (MAP) registered bed-side on admission, resulted, after correction for all confounders factors, the sole factors significantly associated with a higher risk of all-cause mortality in long-term (HR 1.06, p=0.0057; HR 0.97, p=0.0218; respectively). Study population was subdivided according to median values of IVC diameter (23 mm) and MAP (93.3 mm Hg). The Kaplan–Meier curve showed that HF patients with both IVC ≥ 23 mm and MAP b93.3 mm Hg on admission had reduced probability of survival free from all-cause death (log rank p = 0.0070 and log rank p = 0.0028, respectively). In patients hospitalized for acute HF, IVC diameter, measured by hand-carried ultrasound (HCU), and MAP detected on admission are strong predictors of long-term all-cause mortality. The data suggest the need for a careful clinical-therapeutic surveillance on these patients during the post-discharge period. IVC diameter and MAP can be utilized as parameters to stratify prognosis on admission and to be supervised during follow-up. Copyright © 2015 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  11. Inferior vena cava filter insertion through the popliteal vein: enabling the percutaneous endovenous intervention of deep vein thrombosis with a single venous access approach in a single session

    Science.gov (United States)

    Kim, Hyoung Ook; Kim, Jae Kyu; Park, Jin Gyoon; Yim, Nam Yeol; Kang, Yang Jun; Jung, Hye Doo

    2016-01-01

    PURPOSE We aimed to evaluate the efficiency of placing an inferior vena cava (IVC) filter through the same popliteal vein access site used for percutaneous endovenous intervention in patients with extensive lower extremity deep vein thrombosis. METHODS This retrospective study included 21 patients who underwent IVC filter insertion through the popliteal vein over a three-year period. Patient medical records were reviewed for the location of the deep vein thrombosis, result of filter removal, and total number of endovascular procedures needed for filter insertion and recanalization of the lower extremity venous system. Follow-up lower extremity computed tomography (CT) venography was also reviewed in each patient to assess the degree of filter tilt in the IVC. RESULTS All patients had extensive lower extremity deep vein thrombosis involving the iliac vein and/or femoral vein. Seventeen patients showed deep vein thrombosis of the calf veins. In all patients, IVC filter insertion and the recanalization procedure were performed during a single procedure through the single popliteal vein access site. In the 17 patients undergoing follow-up CT, the mean tilt angle of the filter was 7.14°±4.48° in the coronal plane and 8.77°±5.49° in the sagittal plane. Filter retrieval was successful in 16 of 17 patients (94.1%) in whom filter retrieval was attempted. CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention. PMID:27559713

  12. Use of ultrasound measurement of the inferior vena cava diameter as an objective tool in the assessment of children with clinical dehydration.

    Science.gov (United States)

    Chen, Lei; Kim, Yunie; Santucci, Karen A

    2007-10-01

    Bedside ultrasonography (US) measurement of the inferior vena cava (IVC) and aorta (Ao) may be useful in objectively assessing children with dehydration. The objectives of this study were 1) to compare the IVC and Ao diameters (IVC/Ao) ratio of dehydrated children with controls and 2) to compare the IVC/Ao ratio before and after intravenous (i.v.) rehydration in children with dehydration. This prospective observational study was performed in an urban pediatric emergency department. Children between 6 months and 16 years of age with clinical evidence of dehydration were enrolled. Bedside US measurements of the IVC and Ao were taken before and immediately after i.v. fluids were administered. An age-, gender-, and weight-matched control without dehydration was enrolled for each subject. The IVC/Ao ratios of subjects and controls were compared using Wilcoxon signed rank test, as were the ratios before and after i.v. hydration for each subject. Thirty-six pairs of subjects and matched controls were enrolled. The IVC/Ao ratios in the subjects were lower as compared with controls (mean of 0.75 vs. 1.01), with a mean difference of 0.26 (95% confidence interval = 0.18 to 0.35). In subjects, the IVC/Ao ratios were significantly lower before i.v. hydration (mean of 0.75 vs. 1.09), with a mean difference of 0.34 (95% confidence interval = 0.29 to 0.39). As measured by bedside US measurement, the IVC/Ao ratio is lower in children clinically assessed to be dehydrated. Furthermore, it increases with administration of i.v. fluid boluses.

  13. Establishment of an inferior vena cava filter database and interventional radiology led follow-up - retrieval rates and patients lost to follow-up.

    Science.gov (United States)

    Klinken, Sven; Humphries, Charlotte; Ferguson, John

    2017-10-01

    To evaluate the rates of inferior vena cava (IVC) filter retrieval and the number of patient's lost to follow-up, before and after the establishment of an IVC filter database and interventional radiology (inserting physician) led follow-up. On the 1st of June 2012, an electronic interventional radiology database was established at our Institution. In addition, the interventional radiology team took responsibility for follow-up of IVC filters. Data were prospectively collected from the database for all patients who had an IVC filter inserted between the 1st June 2012 and the 31st May 2014. Data on patients who had an IVC filter inserted between the 1st of June 2009 to the 31st of May 2012 were retrospectively reviewed. Patient demographics, insertion indications, filter types, retrieval status, documented retrieval decisions, time in situ, trackable events and complications were obtained in the pre-database (n = 136) and post-database (n = 118) cohorts. Attempted IVC filter retrieval rates were improved from 52.9% to 72.9% (P = 0.001) following the establishment of the database. The number of patients with no documented decision (lost to follow-up) regarding their IVC filter reduced from 31 of 136 (23%) to 0 of 118 patients (P = database group (113 as compared to 137 days, P = 0.129). Following the establishment of an IVC filter database and interventional radiology led follow-up, we demonstrate a significant improvement in the attempted retrieval rates of IVC filters and the number of patient's lost to follow-up. © 2017 The Royal Australian and New Zealand College of Radiologists.

  14. Axitinib for preoperative downstaging of renal cell carcinoma with sarcomatoid differentiation and direct invasion of the duodenum and inferior vena cava: a case report

    Directory of Open Access Journals (Sweden)

    Yuki H

    2014-02-01

    Full Text Available Hideo Yuki,1,* Takao Kamai,1,* Keiichi Kubota,2 Hideyuki Abe,1 Daisaku Nishihara,1 Tomoya Mizuno,1 Akinori Masuda,1 Hironori Betsunoh,1 Masahiro Yashi,1 Yoshitatsu Fukabori,1 Ken-Ichiro Yoshida1 1Department of Urology, 2Department of Gastroenterological Surgery, Dokkyo Medical University, Mibu, Tochigi, Japan *These authors contributed equally to this manuscript Background: Renal cell carcinoma (RCC with sarcomatoid differentiation is invasive, refractory to treatment, and has a higher mortality. Therefore, systemic therapy is still challenging, and the curative resection of localized or locally advanced RCC with sarcomatoid differentiation is very important. Axitinib is a potent and selective second-generation vascular endothelial growth factor receptor tyrosine kinase inhibitor with improved safety and tolerability. Axitinib is generally recommended as second-line therapy for advanced RCC because the phase III axitinib versus sorafenib in advanced RCC (AXIS trial demonstrated that it achieved longer progression-free survival than sorafenib in patients with metastatic RCC after failure of an approved first-line regimen. Methods: We present a 73-year-old man who had a large (13 cm in diameter right RCC with sarcomatoid differentiation that directly invaded the duodenum and inferior vena cava. The patient presented with gastrointestinal bleeding, was unable to eat solid food, and had become emaciated. Thus, his classification was poor risk with anemia, hypercalcemia, and poor performance status, according to the Memorial Sloan-Kettering Cancer Center criteria. He seemed unlikely to survive if radical nephrectomy, cavotomy with thrombectomy, and pancreatoduodenectomy were performed. To reduce the tumor burden and potential operative complications, we administered axitinib as first-line neoadjuvant therapy. Results: Six weeks of treatment reduced the tumor burden without causing severe toxicities. Subsequently, radical right nephrectomy, cavotomy

  15. Factors Associated with Advanced Inferior Vena Cava Filter Removals: A Single-Center Retrospective Study of 203 Patients Over 7 Years

    International Nuclear Information System (INIS)

    Dowell, Joshua D.; Wagner, Daniel; Elliott, Eric; Yildiz, Vedat O.; Pan, Xueliang

    2016-01-01

    PurposeTo identify factors associated with advanced inferior vena cava filter (IVCF) retrieval to raise awareness on technical considerations, retrieval efficiency, and patient safety.Materials and MethodsA single-center retrospective review was performed of 203 consecutive retrievable IVC filters placed between 2007 and 2014. Attempted retrievals were classified as advanced if the routine “snare and sheath” technique was initially unsuccessful after multiple attempts, or an alternate endovascular maneuver or access site was utilized. Patient and filter characteristics were recorded.Results203 attempted retrievals were reviewed (48.7 % male, 51.2 % female, mean age 52.7 years, mean dwell time 109 days). Advanced retrievals were observed in 20 patients (9.8 %) (15 females, 5 males). Fluoroscopy time (p ≤ 0.01, 34.3 ± 21.1 and 5.3 ± 4.5 min for advanced retrievals and routine retrievals respectively, same below), gender (p = 0.031), and retrieval tilt angle (p ≤ 0.01, 5.7 ± 5.10° vs. 11.9 ± 11.03°) were associated with advanced retrievals. Females were 3.16 times more likely to have an advanced retrieval performed than males with a significantly higher tilt angle in those with advanced retrieval. History of cancer (p = 0.502), dwell time (p = 0.916), retrieval caval diameter (p = 0.053), placement caval diameter (p = 0.365), filter type (p = 0.710), strut perforation (p = 0.506), placement tilt angle (p = 0.311), and age (p = 0.558) were not found significantly associated with advanced retrievals.ConclusionsWomen are at increased risk for advanced filter retrieval secondary to a significant change in filter tilt over time compared to men, independent of filter type or competing demographic or filter risks, likely placing them at increased risk for higher procedural fluoroscopy times

  16. Factors Associated with Advanced Inferior Vena Cava Filter Removals: A Single-Center Retrospective Study of 203 Patients Over 7 Years

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, Joshua D., E-mail: Joshua.Dowell@osumc.edu; Wagner, Daniel, E-mail: Daniel.Wagner@osumc.edu; Elliott, Eric, E-mail: Eric.Elliott@osumc.edu [The Ohio State University Wexner Medical Center, Department of Radiology, Division of Interventional Radiology (United States); Yildiz, Vedat O., E-mail: Vedat.Yildiz@osumc.edu; Pan, Xueliang, E-mail: Jeff.Pan@osumc.edu [The Ohio State University Wexner Medical Center, Center for Biostatistics (United States)

    2016-02-15

    PurposeTo identify factors associated with advanced inferior vena cava filter (IVCF) retrieval to raise awareness on technical considerations, retrieval efficiency, and patient safety.Materials and MethodsA single-center retrospective review was performed of 203 consecutive retrievable IVC filters placed between 2007 and 2014. Attempted retrievals were classified as advanced if the routine “snare and sheath” technique was initially unsuccessful after multiple attempts, or an alternate endovascular maneuver or access site was utilized. Patient and filter characteristics were recorded.Results203 attempted retrievals were reviewed (48.7 % male, 51.2 % female, mean age 52.7 years, mean dwell time 109 days). Advanced retrievals were observed in 20 patients (9.8 %) (15 females, 5 males). Fluoroscopy time (p ≤ 0.01, 34.3 ± 21.1 and 5.3 ± 4.5 min for advanced retrievals and routine retrievals respectively, same below), gender (p = 0.031), and retrieval tilt angle (p ≤ 0.01, 5.7 ± 5.10° vs. 11.9 ± 11.03°) were associated with advanced retrievals. Females were 3.16 times more likely to have an advanced retrieval performed than males with a significantly higher tilt angle in those with advanced retrieval. History of cancer (p = 0.502), dwell time (p = 0.916), retrieval caval diameter (p = 0.053), placement caval diameter (p = 0.365), filter type (p = 0.710), strut perforation (p = 0.506), placement tilt angle (p = 0.311), and age (p = 0.558) were not found significantly associated with advanced retrievals.ConclusionsWomen are at increased risk for advanced filter retrieval secondary to a significant change in filter tilt over time compared to men, independent of filter type or competing demographic or filter risks, likely placing them at increased risk for higher procedural fluoroscopy times.

  17. A pilot study on the randomization of inferior vena cava filter placement for venous thromboembolism prophylaxis in high-risk trauma patients.

    Science.gov (United States)

    Rajasekhar, Anita; Lottenberg, Lawrence; Lottenberg, Richard; Feezor, Robert J; Armen, Scott B; Liu, Huazhi; Efron, Philip A; Crowther, Mark; Ang, Darwin

    2011-08-01

    Placement of prophylactic inferior vena cava filters (pIVCFs) for the prevention of pulmonary embolism (PE) in high-risk trauma patients (HRTPs) are widely practiced despite the lack of Level I data supporting this use. We report the 2-year interim analysis of the Filters in Trauma pilot study. This is a single institution, prospective randomized controlled pilot feasibility study in a Level I trauma center. HRTPs were identified for pIVCF placement by the Eastern Association for the Surgery of Trauma guidelines. From November 2008 to November 2010, HRTPs were enrolled and randomized to either pIVCF or no pIVCF. All patients received pharmacologic prophylaxis when safe. Primary outcomes included feasibility objectives and secondary outcomes were incidence of PE, deep vein thrombosis (DVT), and death. Thirty-four of 38 enrolled patients were eligible for analysis. The baseline sociodemographic characteristics were balanced between the both groups. Results of the feasibility objectives included: time from admission to enrollment (mean, 47.4 hours ± 22.0 hours), time from enrollment to randomization (mean, 4.8 hours ± 9.1 hours), time from randomization to IVCF placement (mean, 16.9 hours ± 9.2 hours), adherence to weekly compression ultrasound within first month (IVCF group = 44.4%; non-IVCF group = 62.5%), and 1-month clinical follow-up (IVCF group = 83.3%; non-IVCF group = 100%). At 6-month follow-up, one PE in the nonfilter group and one DVT in the filter group had occurred. One non-PE-related death occurred in the filter group. Barriers to enrollment included inability to obtain informed consent due to patient refusal or no next of kin identified and delayed notification of eligibility status. Our pilot study demonstrates for the first time that a randomized controlled trial evaluating the efficacy of pIVCFs in trauma patients is feasible. This pilot data will be used to inform the design of a multicenter randomized controlled trial to determine the incidence

  18. Tumor thrombus of inferior vena cava in patients with renal cell carcinoma – clinical and oncological outcome of 50 patients after surgery

    Directory of Open Access Journals (Sweden)

    Kocot Arkadius

    2012-06-01

    Full Text Available Abstract Background To evaluate oncological and clinical outcome in patients with renal cell carcinoma (RCC and tumor thrombus involving inferior vena cava (IVC treated with nephrectomy and thrombectomy. Methods We identified 50 patients with a median age of 65 years, who underwent radical surgical treatment for RCC and tumor thrombus of the IVC between 1997 and 2010. The charts were reviewed for pathological and surgical parameters, as well as complications and oncological outcome. Results The median follow-up was 26 months. In 21 patients (42% distant metastases were already present at the time of surgery. All patients underwent radical nephrectomy, thrombectomy and lymph node dissection through a flank (15 patients/30%, thoracoabdominal (14 patients/28% or midline abdominal approach (21 patients/42%, depending upon surgeon preference and upon the characteristics of tumor and associated thrombus. Extracorporal circulation with cardiopulmonary bypass (CPB was performed in 10 patients (20% with supradiaphragmal thrombus of IVC. Cancer-specific survival for the whole cohort at 5 years was 33.1%. Survival for the patients without distant metastasis at 5 years was 50.7%, whereas survival rate in the metastatic group at 5 years was 7.4%. Median survival of patients with metastatic disease was 16.4 months. On multivariate analysis lymph node invasion, distant metastasis and grading were independent prognostic factors. There was no statistically significant influence of level of the tumor thrombus on survival rate. Indeed, patients with supradiaphragmal tumor thrombus (n = 10 even had a better outcome (overall survival at 5 years of 58.33% than the entire cohort. Conclusions An aggressive surgical approach is the most effective therapeutic option in patients with RCC and any level of tumor thrombus and offers a reasonable longterm survival. Due to good clinical and oncological outcome we prefer the use of CPB with extracorporal

  19. Percutaneous transhepatic biliary endoprostheses

    International Nuclear Information System (INIS)

    Lammer, J.

    1985-01-01

    Eighty biliary endoprostheses were introduced by the transhepatic route in sixty patients with obstructive jaundice. Complication rate was 21% (no mortality). Average survival time is sixteen weeks (maximum 53 weeks). In most patients, a 12 F teflon endoprosthesis was introduced four to five days after the initial catheter drainage. Patients in poor condition had a primary implant of a 9 F endoprosthesis. A combined transhepatic/transoral implantation was carried out five times. Results have shown that implantation of a prosthesis is as effective as a surgical bypass operation for palliation of obstructive jaundice and that it is better than catheter drainage. In-vitro experiments have indicated that failure of a 12 F prosthesis due to encrustation may be expected in about 23 weeks. This is in line with the survival time of patients with carcinomas. (orig.) [de

  20. Quantitative measurement of hemodynamics of inferior vena in healthy volunteers with phase-contrast MR imaging at 3.0 T

    International Nuclear Information System (INIS)

    Ruan Zhibing; Fan Guangming; Jiao Jun; Min Dingyu

    2014-01-01

    Objective: To explore the feasibility of quantitative hemodynamics measurement of inferior vena cava (IVC) in healthy volunteers with phase-contrast sequence on 3.0 T MR system (3.0 T PC-MRI), and to evaluate the relationship between IVC lumen area, blood flow, and velocity. Methods: Fifty healthy adult volunteers prospective underwent IVC PC-MRI at 3.0 T MR system. All volunteers were from our hospital for the routine chest or abdomen examinations, no heart disease and lung disease always, heart rate, blood pressure, electrocardiogram was in normal range, no abnormalities were found in clinical and abdominal imaging examinations, and IVC disease was excluded by ultrasonic examination. The area (A), mean velocity (MV), mean flux (MF), regurgitant fraction (RF) and time-flow curve of upper and middle segments of IVC during one cardiac cycle were observed. Independent samples t test was used to compare IVC lumen area and blood flow, velocity between different genders, different age groups (18 to 30 years old group, more than 30 years old group) and different phase velocity encoding value of IVC middle segment, one-way ANOVA was used to compare different phase velocity encoding value of IVC upper segment [(60, 80, 100)cm/s]. Pearson correlation coefficient and regression equation were used to evaluate the relationships between area, blood flow, and velocity. Results: Among 50 patients with successful completion of the examination, significant difference was found in A, MV, MF and RF between the different IVC segments. MF of the IVC middle segment were (37.94 ± 7.32) and (33.68 ± 6.65) ml/s in male (n=24) and female (n=26), respectively; significant difference was found in different genders (t=2.49, P=0.017). MF of upper segment and middle segments of IVC were (54.89 ± 10.98) and (38.29 ± 7.54) ml/s in 18 to 30 years old group (n=27), while MF of upper segment and the middle of IVC were (44.96 ± 8.49) and (32.65 ± 5.59) ml/s in older than 30 years old group (n=23

  1. Late endovascular removal of Günther-Tulip inferior vena cava filter and stent reconstruction of chronic post-thrombotic iliocaval obstruction after 4753 days of filter dwell time: a case report with review of literature.

    Science.gov (United States)

    Doshi, Mehul Harshad; Narayanan, Govindarajan

    2016-12-01

    Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombotic obstruction of the iliocaval junction related to Günther-Tulip IVC filter (Cook Medical Inc, Bloomington, IN) with dwell time of 4753 days, treated successfully with endovascular filter removal and stent reconstruction. Filter retrieval and stent reconstruction may be a treatment option in symptomatic patients with filter-related chronic IVC or iliocaval junction obstruction, even after prolonged dwell time.

  2. Non-retrieval of inferior vena cava filters as a patient safety concern: evaluation of a new process improvement project to increase retrieval rates in a vascular and interventional radiology clinic.

    Science.gov (United States)

    Brown, Joshua; Talbert, Jeffery; Pennington, Ryan; Han, Qiong; Raissi, Driss

    2018-01-01

    Retrieval of inferior vena cava filters (IVCFs) is important to decrease the long-term risk of complications associated with indwelling devices. Our hospital experienced low retrieval rates and implemented a low-cost intervention and evaluation for quality improvement. The working hypothesis was that a simple, mailed letter intervention could increase retrieval rates by increasing patient and primary care provider knowledge of the need for retrieval. For all prospective patients who received a retrievable IVCF during the intervention period from January 1, 2014 to February 29, 2016, patients and their primary care providers were mailed letters encouraging contact with the clinic for evaluation of eligibility for retrieval. The main outcome was retrieval of the IVCF if clinically indicated with a secondary outcome of time-to-retrieval. A pre-intervention control group from October 1, 2011 to December 31, 2013 was used to evaluate the impact of the intervention. Competing risks, time-to-event analysis was used to compare the pre- and post-intervention period retrieval rates correcting for patients who died during follow-up. Between the pre- and post-intervention periods, crude retrieval rates increased from 4.4% to 8.1% with a 12-fold change at comparable time points. The time-to-retrieval in the pre-intervention period was a mean (SD) of 503 (207) days with a median (IQR) of 505 (301-742). In the post-intervention period, time-to-retrieval was a mean (SD) of 119 (83) days and with median (IQR) of 128 (38-164) days. This low-cost intervention significantly increased retrieval rates in a single clinic. However, retrieval rates remain low and can be further improved. Ongoing interventions, including improved patient follow-up and physician education, are being implemented to further improve retrieval and use of inferior vena cava filters. Implanting clinics should implement quality improvement initiatives to improve patient care and follow-up with IVCFs to ensure

  3. Proposal for a new classification of variations in the iliac venous system based on internal iliac veins: a case series and a review of double and left inferior vena cava.

    Science.gov (United States)

    Hayashi, Shogo; Naito, Munekazu; Hirai, Shuichi; Terayama, Hayato; Miyaki, Takayoshi; Itoh, Masahiro; Fukuzawa, Yoshitaka; Nakano, Takashi

    2013-09-01

    There are many reports on variations in the inferior vena cava (IVC), particularly double IVC (DIVC) and left IVC (LIVC). However, no systematic report has recorded iliac vein (IV) flow patterns in the DIVC and LIVC. In this study, we examined IV flow patterns in both DIVC and LIVC observed during gross anatomy courses conducted for medical students and in previously reported cases. During the gross anatomy courses, three cases of DIVC and one case of LIVC were found in 618 cadavers. The IV flow pattern from these four cases and all other previously reported cases can be classified into one of the following three types according to the vein into which the internal iliac vein drained: the ipsilateral external IV; confluence of the ipsilateral external IV and IVC; and the communicating vein, which connects the IVC and the contralateral IVC or its iliac branch. This classification, which is based on the internal IV course, is considered to be useful because IV variations have the potential to cause clinical problems during related retroperitoneal surgery, venous interventional radiology, and diagnostic procedures for pelvic cancer.

  4. Psoas abscess secondary to retroperitoneal distant metastases from squamous cell carcinoma of the cervix with thrombosis of the inferior vena cava and duodenal infiltration treated by Whipple procedure: A case report and review of the literature.

    Science.gov (United States)

    Mehdorn, Matthias; Petersen, Tim-Ole; Bartels, Michael; Jansen-Winkeln, Boris; Kassahun, Woubet Tefera

    2016-08-11

    Psoas abscess is a rare clinical disease of various origins. Most common causes include hematogenous spread of bacteria from a different primary source, spondylodiscitis or perforated intestinal organs. But rarely some abscesses are related to malignant metastatic disease. In this case report we present the case of a patient with known squamous cell carcinoma of the cervix treated with radio-chemotherapy three years prior. She now presented with a psoas abscess and subsequent complete inferior vena cava thrombosis, as well as duodenal and vertebral infiltration. The abscess was drained over a prolonged period of time and later was found to be a complication caused by metastases of the cervical carcinoma. Due to the massive extent of the metastases a Whipple procedure was performed to successfully control the local progress of the metastasis. As psoas abscess is an unspecific disease which presents with non-specific symptoms adequate therapy may be delayed due to lack of early diagnostic results. This case report highlights the difficulties of managing a malignant abscess and demonstrates some diagnostic pitfalls that might be encountered. It stresses the necessity of adequate diagnostics to initiate successful therapy. Reports on psoas abscesses that are related to cervix carcinoma are scarce, probably due to the rarity of this event, and are limited to very few case reports. We are the first to report a case in which an extensive and complex abdominal procedure was needed for local control to improve quality of life.

  5. Transhepatic venous catheters for hemodialysis

    Directory of Open Access Journals (Sweden)

    Mohamed El Gharib

    2014-06-01

    Conclusion: Based on our findings, transhepatic hemodialysis catheters have proven to achieve good long-term functionality. A high level of maintenance is required to preserve patency, although this approach provides remarkably durable access for patients who have otherwise exhausted access options.

  6. Renal carcinoma infiltrating inferior vena cava and combined valvular heart disease - one-stage uro-cardiological procedure: a case report

    Directory of Open Access Journals (Sweden)

    Zapala Lukasz

    2010-07-01

    Full Text Available Abstract Standard treatment of patients with coexisting cardiac and non-cardiac diseases includes two separate operations. We report a case of 55-year-old man with combined valvular heart disease and renal carcinoma infiltrating inferior caval vein, who underwent one-stage cardio-urologic procedure. In the first step, mitral and tricuspid valvuloplasty were performed by cardiac surgeons. Then, urologists performed radical nephrectomy and thrombectomy. The postoperative course was uneventful. In twelve months follow-up the patient shows no signs of reccurrence and he had no symptoms of cardiac disease. To the best of our knowledge such a case has never been reported before in the literature.

  7. Vessel wall reaction after vena cava filter placement

    NARCIS (Netherlands)

    Hoekstra, A; Elstrodt, JM; Nikkels, PGJ; Tiebosch, ATMG

    2002-01-01

    Purpose: To evaluate the interaction between the Cordis Keeper vena caval filter and vessel wall in a porcine model. Methods: Implantation of the filter was performed in five pigs. Radiologic data concerning inferior vena cava (IVC) diameter and filter patency, filter leg span, and stability were

  8. Topography and distribution of ostia venae hepatica in the ...

    African Journals Online (AJOL)

    BACKGROUND: Openings of hepatic veins into the retrohepatic surface of the inferior vena cava. (ostia venae hepatica) play a part in controlling hepatic circulation by acting as collateral channels in obstruction. Their topography and distribution must be taken into account during catheterization and liver transplantation.

  9. The Clinical Presentation, Survival Outcomes, and Management of Patients With Renal Cell Carcinoma and Cardiac Metastasis Without Inferior Vena Cava Involvement: Results From a Pooled Clinical Trial Database and Systematic Review of Reported Cases.

    Science.gov (United States)

    Viteri Malone, Mariuxi A; Ares, Gustavo Ruiz; De Velasco, Guillermo; Brandão, Raphael; Lin, Xun; Norton, Craig; Simantov, Ronit; Moslehi, Javid; Krajewski, Katherine M; Choueiri, Toni K; McKay, Rana R

    2018-04-01

    Cardiac metastases from renal cell carcinoma (RCC) are uncommon and there are limited data regarding the presentation and outcomes of this population. The objective of this study was to evaluate the characteristics and outcomes of patients with RCC with cardiac metastasis without inferior vena cava (IVC) involvement. We conducted a pooled retrospective analysis of metastatic RCC patients treated in 4 clinical trials. Additionally, we conducted a systematic review of cases reported in the literature from 1973 to 2015. Patients with cardiac metastases from RCC without IVC involvement were included. Patient and disease characteristics were described. Additionally, treatments, response to therapy, and survival outcomes were summarized. Of 1765 metastatic RCC patients in the clinical trials database, 10 had cardiac metastases without IVC involvement. All patients received treatment with targeted therapy. There was 1 observed partial response (10%) and 6 patients showed stable disease (60%). The median progression-free survival was 6.9 months. The systematic review of reported clinical cases included 39 patients. In these patients, the most common cardiac site of involvement was the right ventricle (51%; n = 20). Patients were treated with medical (28%; n = 11) and/or surgical treatment (49%; n = 19) depending on whether disease was isolated (n = 13) or multifocal (n = 26). To our knowledge, this is the first series to report on the presentation and outcomes of patients with cardiac metastasis without IVC involvement in RCC. We highlight that although the frequency of patients with cardiac metastases without IVC involvement is low, these patients have a unique clinical presentation and warrant special multidisciplinary management. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Vena caval impalement: an unusual lawn mower injury in a child.

    Science.gov (United States)

    Muńoz-Juárez, M; Drugas, G T; Hallett, J W; Zietlow, S P

    1998-06-01

    Penetrating injury to the vena cava is a potentially life threatening condition that necessitates prompt recognition and immediate treatment. Herein we describe a unique lawn mower-related injury in a 4-year-old boy, resulting in the impalement of the inferior vena cava by a foreign body projectile. Relevant concepts in the management of children with lawn mower injuries are discussed, with emphasis on penetrating injury to the inferior vena cava.

  11. Kirurgisk radikal resektion af leiomyosarkom i retrohepatiske vena cava med intrakardial tumortrombosering

    DEFF Research Database (Denmark)

    Pedersen, Christian Ross; Larsen, Peter Nørgaard; Arendrup, Henrik C

    2005-01-01

    Sarcoma of the inferior vena cava (IVC) is a rare clinical entity. Surgical treatment of IVC is associated with improved survival. This case report describes a 42-year-old woman with biopsy-proven leiomyosarcoma of the inferior vena cava with intracardial tumour growth. The primary tumour was only...

  12. Predicting Fluid Responsiveness Using Bedside Ultrasound Measurements of the Inferior Vena Cava and Physician Gestalt in the Emergency Department of an Urban Public Hospital in Sub-Saharan Africa.

    Directory of Open Access Journals (Sweden)

    Hendry Robert Sawe

    Full Text Available Bedside inferior vena cava (IVC ultrasound has been proposed as a non-invasive measure of volume status. We compared ultrasound measurements of the caval index (CI and physician gestalt to predict blood pressure response in patients requiring intravenous fluid resuscitation.This was a prospective study of adult emergency department patients requiring fluid resuscitation. A structured data sheet was used to record serial vital signs and the treating clinician's impression of patient volume status and cause of hypotension. Bedside ultrasound CI measurements were performed at baseline and after each 500mL of fluid. Receiver operating characteristic (ROC curve analysis was performed to characterize the relationship between CI and Physician gestalt, and the change in mean arterial pressure (MAP.We enrolled 364 patients, 52% male, mean age 36 years. Indications for fluid resuscitation were haemorrhage (54%, dehydration (30%, and sepsis (17%. Receiver operating characteristic curve analysis found optimal CI cut-off values of 45%, 52% and 53% to predict a MAP rise of 5, 8 and 10 mmHg per litre of fluid, respectively. The sensitivity and specificity of CI of 50% for predicting a 10mmHg increase in MAP per litre were 88% (95%CI 81-93% and 73% (95%CI 67-79%, respectively, area under the curve (AUC = 0.85 (0.81-0.89. The sensitivity and specificity of physician gestalt estimate of volume depletion severity were 68% (95%CI 60-75% and 86% (95%CI 80-90%, respectively, AUC = 0.83 (95% CI: 0.79-0.87. Those with a baseline CI ≥ 50% (51% of patients had a 2.8-fold greater fluid responsiveness than those with a baseline CI<50% (p<0.0001.Ultrasound measurement of the CI can predict blood pressure response among patients requiring intravenous fluid resuscitation and may be useful in early identification of patients who will benefit most from volume resuscitation, and those who will likely require other interventions.

  13. Inferior Vena Cava Filter Placement and Removal

    Science.gov (United States)

    ... be positioned on your back. You may be connected to monitors that track your heart rate, blood ... avoid driving for 24 hours and lifting heavy objects and climbing stairs for 48 hours. Your physician ...

  14. Isolated inferior mesenteric portal hypertension with giant inferior mesenteric vein and anomalous inferior mesenteric vein insertion

    Directory of Open Access Journals (Sweden)

    G Raghavendra Prasad

    2013-01-01

    Full Text Available Extrahepatic portal hypertension is not an uncommon disease in childhood, but isolated inferior mesenteric portal varices and lower gastrointestinal (GI bleed have not been reported till date. A 4-year-old girl presented with lower GI bleed. Surgical exploration revealed extrahepatic portal vein obstruction with giant inferior mesenteric vein and colonic varices. Inferior mesenteric vein was joining the superior mesenteric vein. The child was treated successfully with inferior mesenteric - inferior vena caval anastomosis. The child was relieved of GI bleed during the follow-up.

  15. One-day transhepatic billary stricture dilatation

    International Nuclear Information System (INIS)

    Mueller, P.R.; Saini, S.; Hahn, P.F.; Silverman, S.G.; Ferrucci, J.T.

    1989-01-01

    To overcome technical problems in percutaneous transhepatic dilatation or biliary strictures, the authors performed the entire procedure in a single session with the patient under general anesthesia (N = 7). Six patients had a biliary-enteric anastomosis, and one patient had a traumatic mid common bile duct stricture. All bile ducts were of normal caliber or were minimally dilated by US or transhepatic cholangiography. Dilatation was performed via a fresh transhepatic drainage catheter in six patients and via an in-dwelling T-tube in one patient. High-pressure balloons (10-12 mm) were placed after catheter dilation of the tract, and balloons were inflated for 5-10 minutes three to five times. Dilation was stopped with a waist was no longer present. No strictures have recurred in patients followed up to 24 months

  16. Vena cava filter behavior and endovascular response : An experimental in vivo study

    NARCIS (Netherlands)

    Hoekstra, A; Hoogeveen, Y; Elstrodt, JM; Tiebosch, ATMG

    2003-01-01

    Purpose: To evaluate the behavior and endovascular response of a new nitinol permanent vena cava filter, the TrapEase. Methods: Percutaneous implantation of the filter was performed in six goats, with inferior vena cava (IVC) diameter close to that of man. Radiologic data concerning the IVC, filter

  17. Experience with three percutaneous vena cava filters

    International Nuclear Information System (INIS)

    McCowan, T.C.; Ferris, E.J.; Harshfield, D.L.; Hassell, D.R.; Baker, M.L.

    1987-01-01

    Twenty-one Kimray-Greenfield, 33 bird's nest, and 19 Amplatz vena cava filters were placed percutaneously. The Kimray-Greenfield filter was the most difficult to insert. The major problem was the insertion site, which required venipuncture with a 24-F catheter. Minor hemorrhage was frequent, and femoral vein thrombosis occurred in four patients. No migration, caval thrombosis, or pulmonary emboli were seen after Kimray-Greenfield filter placement. The bird's nest filter was relatively easy to insert, although in two cases the filter prongs could not be adequately seated in the wall of the inferior vena cava. Three patients with bird's nest filters had thrombosis below the filter, and three filters migrated to the heart. One migrated filter could not be removed. One patient had multiple small pulmonary emboli at autopsy. No other pulmonary emboli after filter placement were noted. The Amplatz filter was the easiest of the three filters to insert. Only one patient with an Amplatz filter had thrombosis of the vena cava below the filter. No filter migrations were documented, and no recurrent pulmonary emboli were found on clinical or radiologic follow-up. The Amplatz vena cava filter is easier to place than percutaneous Kimray-Greenfield or bird's nest filters, has a low complication rate, and has proven to be clinically effective in preventing pulmonary emboli

  18. Collateral veins in inferior caval vein occlusion demonstrated via CT

    International Nuclear Information System (INIS)

    Lien, H.H.; Lund, G.

    1983-01-01

    CT-scans of 12 patients with tumour-induced occlusion of the inferior vena cava were studied with regard to collateral veins. A comparison was performed with findings at phlebography in 10 patients and at autopsy in 2. The site and appearance of the main collateral pathway are presented. A close study of vascular structures renders useful information on collateral circulation in occlusion of the inferior vena cava. (orig.)

  19. Colapsibilidade da Veia Cava Inferior e sinais e sintomas de insuficiência cardíaca: novos insights e possíveis associações Inferior Vena Cava collapsibility and heart failure signs and symptoms: new insights about possible links

    Directory of Open Access Journals (Sweden)

    Renato De Vecchis

    2012-06-01

    Full Text Available FUNDAMENTO: Nos pacientes com Insuficiência Cardíaca Crônica (ICC foram propostas medidas ultrassonográficas do Índice de Colapsibilidade da Veia Cava Inferior (ICVCI para obter uma avaliação e classificação minuciosa da congestão hemodinâmica. OBJETIVO: A finalidade deste estudo era correlacionar os achados no exame físico com o ICVCI em pacientes com ICC. MÉTODOS: De acordo com um projeto de coorte retrospectivo, analisamos 54 pacientes com ICC, direita ou biventricular, classe NYHA III. O plano era determinar se alguma faixa de ICVCI basal poderia predizer uma persistência ou agravamento da congestão clínica achada no final do acompanhamento subsequente (isto é, após 1-2 meses do tratamento oral otimizado. Para essa finalidade, os pacientes foram subdivididos em três grupos de acordo com o valor de ICVCI basal: ≤ 15% (13 pts, 16 - 40% (21 pts e > 40% (20 pts. Diversos critérios clínicos de congestão foram comparados por meio dos três grupos e incorporados subsequentemente ao modelo multivariado de Cox. RESULTADOS: Preditores multivariados de alto escore de congestão foram distensão da veia jugular (FC: 13,38 95% IC: 2,13 - 84 p = 0,0059 e estertores (FC: 11 95% C.I : 1,45 - 83,8 p = 0,0213. O ICVCI ≤ 15% esteve sempre associado com um alto escore de congestão na segunda visita; todavia, o ICVCI o ≤ 15% não predisse um alto escore de congestão na segunda visita. CONCLUSÃO: No âmbito da ICC, um baixo ICVCI não predisse, em forma confiável, um elevado escore de congestão. Não obstante, o conjunto com ICVCI ≤ 15% sempre se achou associado com sinais e sintomas de uma ICC descompensada, tanto do lado direito como do esquerdo. (Arq Bras Cardiol. 2012; [online].ahead print, PP.0-0BACKGROUND: In chronic heart failure patients (CHF, ultrasound measurement of inferior vena cava collapsibility index (IVCCI has been proposed to yield careful assessment and grading of the hemodynamic congestion. OBJECTIVE: The

  20. Right to left shunt as a collateral circulation in a patient with superior vena cava syndrome: a case report

    International Nuclear Information System (INIS)

    Kim, Young Sun; Jeon, Seok Chol; Moon, Won Jin; Choi, Yo Won; Seo, Heung Suk; Hahm, Chang Kok; Park, Choong Ki

    1999-01-01

    In patients with superior vena cava syndrome, the form of the collateral circulatory system which communicates with the inferior vena cava via various systemic veins usually varics. We found an instance of unusual collateral circulation : direct communication between the systemic and pulmonary vein in a woman with superior vena cava syndrome caused by metastatic lymph node enlargement. In this report, we describe the CT and radionuclide venographic findings

  1. Malfunctioning Plastic Biliary Endoprosthesis: Percutaneous Transhepatic Balloon Pulling Technique

    Directory of Open Access Journals (Sweden)

    Umberto G. Rossi

    2013-01-01

    Full Text Available Percutaneous transhepatic removal techniques for malfunctioning plastic biliary endoprosthesis are considered safe and efficient second-line strategies, when endoscopic procedures are not feasible. We describe the percutaneous transhepatic balloon pulling technique in a patient with an unresectable malignant hilar cholangiocarcinoma.

  2. In vivo evaluation of a new vena cava filter

    Directory of Open Access Journals (Sweden)

    Gilberto do Nascimento Galego

    2016-01-01

    Full Text Available Abstract Background Pulmonary embolism is an important cause of cardiovascular death. Inferior vena cava filters have been shown to be effective for prevention of this condition. Objectives To determine the safety, performance and efficacy of a new inferior vena cava filter in an ovine model. Methods BKone1 filters are self-centering with over-the-wire deployment, have three filtering regions and are made from nickel-titanium alloy. Eight of these filters were implanted in 8 sheep. The sheep were divided into 4 groups of two animals (A and B and the number of clots injected differed by group. Two clots were injected in group 2, four in group 3, eight in group 4 and zero clots in group 1. A animals underwent euthanasia soon after the procedure and B animals were observed for 30 days and then euthanized after a control cavography. All inferior vena cavas were processed for histological examination. Clots were prepared in a metal mold, sectioned and then radiopaque markers were inserted. Clot capture was analyzed by identifying the radiopaque marker on fluoroscopy. Results No clot migration was observed during follow-up. Control cavographies showed patent inferior vena cavas. Pathological examination indicated little inflammatory tissue response. All clots were captured in the condition with 2 clots, only one clot was missed in the group injected with 4 clots and in the condition of 8 clots, they were partly captured. Conclusions The filters were deployed safely. There was a reduction in efficacy as the number of blood clots increased.

  3. Arterial Complications of Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    L'Hermine, Claude; Ernst, Olivier; Delemazure, Olivier; Sergent, Geraldine

    1996-01-01

    Purpose: To report on the frequency and treatment of arterial complications due to percutaneous transhepatic biliary drainage (PTBD).Materials: Lesions of the intrahepatic artery were encountered in 10 of 525 patients treated by PTBD (2%). Hemobilia followed in 9 patients and subcapsular hematoma in 1. Seven patients had a benign biliary stenosis and 3 had a malignant stenosis.Results: The bleeding resolved spontaneously in 3 patients. In 7 it required arterial embolization, which was successfully achieved either through the percutaneous catheter (n= 3) or by arteriography (n= 4).Conclusion: Arterial bleeding is a relatively rare complication of PTBD that can easily be treated by selective arterial embolization when it does not resolve spontaneously. In this series its frequency was much higher (16%) when the stenosis was benign than when it was malignant (0.6%)

  4. Animal experimental study of safety for a self-made vena cava stent-filter

    International Nuclear Information System (INIS)

    Qin Dingwen; Shi Haibin; Liu Sheng; Li Linsun

    2008-01-01

    Objective: To evaluate the safety of a self-made vena cava stent-filter(VCSF)for prevention of pulmonary embolism. Methods: Fusiform unmhrella-like vena cava filter was made of Nitinol wires and stainless steel metal pole, and then ten mongrel dogs were implanted with these self-made filters and divided into 5 groups according to the different periods (2, 3, 4, 5 and 6 w) of filter placement, with 2 dogs in each group. After the VCSFs were placed in inferior vena cava via the right femoral vein approach, the dogs in each group were bred for 2-6 weeks, respectively. The blood flow of inferior vena cava and the position of the filters were inspected by inferior vena-cavography according to the indwelling periods. Finally the metal pole was retrieved via the femoral vein, leaving the VCSF as permanent venousz stent. The feasibility of retrieval and the free state of filter net with the adhering vascular wall were evaluated. Laparotomies were performed to remove the inferior vena cava from the animals for gross and electron microscopic examinations of the inferior vena cava intimal changes of the involved segment. Results: All 10 VCSFs were placed at the right positions of the dogs successfully. Angiography showed patent inferior vena cava without filter thrombosis at 2-6 weeks. There were no tilting and migration of the filter and all the metal poles were successfully retrieved. The superior and inferior extremities of filter nets could be set free with all the filters turning into venous stents. Postmortem displayed retroperitoneal hemorrhage and caval thrombosis. The barbs of the filters penetrated over the caval adventitial coat. Under electron microscope, a thin layer of neointima already covered the braiding net of VCSFs at 2 weeks after the deployment. The tunica intima became slightly thick at 3-4 weeks and with moderate proliferation at 5-6 weeks. Conclusions: The self-made vena cava stent-filter possesses rather long indwelling period according to the

  5. Tomographic anatomy of the vena cava and renal veins: features relevant to vena cava filter placement

    Directory of Open Access Journals (Sweden)

    Thiago Melo do Espírito Santo

    2015-03-01

    Full Text Available BACKGROUND: There is a growing demand for invasive procedures involving the inferior vena cava, in particular for placement of vena cava filters. It is not always easy to identify the more distal renal vein with cavography, for safe release of filters. OBJECTIVES: To determine parameters for the relationships between the renal veins and the infrarenal vena cava and their corresponding vertebral bodies, their relationships with biotype and the occurrence of anatomic variations, the relationships between vertebral bodies and the bifurcation of the common iliac veins and the distance from this bifurcation to the outflow of the more distal renal vein, with reference to placement of vena cava filters. METHODS: A total of 150 abdominal computed tomography scans conducted from October to November 2011 were analyzed and classified according to the biotype exhibited (using Charpy's angle. Scans were performed at MEDIMAGEM and analyzed at the Integrated Vascular Surgery Service, both part of Hospital da Beneficência Portuguesa in São Paulo, Brazil. RESULTS: In 127 of the 150 scans analyzed (84.66%, the more distal renal vein emerged between the first lumbar intervertebral space (L1-L2 and the body of L2, irrespective of patient biotype. Just 23 patients (15.33% exhibited a more distal renal vein with outflow below the body of L2, i.e. in the projection of the space between L2 and L3. CONCLUSIONS: The radiological correlation between the confluence of the more distal renal vein and vertebral bodies exhibits little variation, irrespective of the biotype of the patient.

  6. Percutaneous transhepatic biliary drainage for hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Qian Xiaojun; Jin Wenhui; Dai Dingke; Yu Ping; Gao Kun; Zhai Renyou

    2007-01-01

    Objective: To evaluate the effect of PTBD in treating malignant biliary obstruction caused by hilar cholangiocarcinoma. Methods: We retrospectively analyzed the data of 103 patients(M:62,F:41)with malignant obstructive jaundice caused by hilar cholangiocarcinoma. After taking percutaneous transhepatic cholangiography, metallic stent or plastic external catheter or external-internal catheter for drainage was deployed and then followed up was undertaken with clinical and radiographic evaluation and laboratory. examination. Results: All patients went though PTBD successfully (100%). According to Bismuth classification, all 103 cases consisted of I type(N=30), II type (N=30), III type (N=26) and IV type (N=17). Thirty-nine cases were placed with 47 stents and 64 eases with drainage tubes. 4 cases installed two stems for bilateral drainage, 2 cases installed two stents because of long segmental strictures with stent in stent, 1 case was placed with three stents, and 3 cases installed stent and plastic catheter together. Sixty-four cases received plastic catheters in this series, 35 cases installed two or more catheters for bilateral drainage, 28 cases installed external and internal drainage catheters, 12 eases installed external drainage catheters, and 24 eases installed both of them. There were 17 patients involving incorporative infection before procedure, 13 cases cured after procedure, and 15 new patients got inflammation after procedure. 13 cases showed increase of amylase (from May, 2004), 8 eases had bloody bile drainage and 1 case with pyloric obstruction. Total serum bilirubin reduced from (386 ± 162) μmol/L to (161 ± 117) μmol/L, (P<0.01) short term curative effect was related with the type of hilar cholangiocarcinoma. The survival time was 186 days(median), and 1, 3, 6, 12 month survival rate were 89.9%, 75.3%, 59.6%, 16.9%, respectively. Conclusion: Percutaneous transhepatic bile drainage is a safe and effective palliative therapy of malignant

  7. Right atrium and superior vena cava pressure measurements in a novel animal model to study one and a half ventricle repair as compared to Fontan type procedure

    Directory of Open Access Journals (Sweden)

    Anil Bhattarai

    2017-01-01

    Full Text Available Background & Objectives: To evaluate the advantages of the one and a half ventricle repair on maintaining a low pressure in the inferior vena cava district. Also evaluate the competition of flows at the superior vena cava – right pulmonary artery anastomosis site, in order to understand the hemodynamic interaction of a pulsatile flow in combination to a laminar one. Materials & Methods: Adult rabbits (n=30 in terminal anaesthesia with a follow up of 8 h were used, randomly distributed in three experimental groups: Group 1: animals with an anastomosis between superior vena cava and right pulmonary artery, as a model of one and one half ventricle repair; Group 2: animals with the cavopulmonary anastomosis followed by clamping of the right pulmonary artery proximal to the anastomosis; and Group 3: sham animals. Pressures of superior vena cava and pulmonary arteries were afterwards measured, in a resting condition as well as after induced pharmacological stress test.Results: In Group 1, superior vena cava pressure was significantly higher, while venous pressure in the inferior vena cava – right atrium district was constant or lower in comparison with the other groups. After stress test, the pressure in the superior vena cava and the heart rate both increased further, but the right ventricular, right atrial and pulmonary artery pressures remained similar to the values in a resting condition. This proved that the inferior vena cava return was well-preserved, and no venous hypertension was present in the inferior vena cava district even after stress test (good exercise tolerance.Conclusion: One and one half ventricle repair can be considered a good surgical strategy for maintaining a low pressure in the inferior vena cava district with potential for right ventricle growth, restoring the more physiological circulation in borderline or failing right ventricle conditions. The experiment presented a positive finding in favour of one and one half

  8. Percutaneous Retrieval of Permanent Inferior Vena Cava Filters

    International Nuclear Information System (INIS)

    Tamrazi, Anobel; Wadhwa, Vibhor; Holly, Brian; Bhagat, Nikhil; Marx, Jonathan K.; Streiff, Michael; Lessne, Mark L.

    2016-01-01

    PurposeTo evaluate the feasibility, risks, and techniques of percutaneous removal of permanent TrapEase and Simon Nitinol IVC filters.Materials and MethodsBetween August 2011 and August 2015, 12 patients (5 women, 7 men; age range, 26–75 years) underwent an attempt at percutaneous removal of permanent TrapEase (10) and Simon Nitinol (2) IVC filters due to a history of IVC filter complications or need for lifelong anticoagulation due to the filter. Medical records were reviewed for filter dwell time, presence of iliocaval deep venous thrombosis, procedural technique, and complications.ResultsFilter dwell times ranged from 7 days to 15 years (mean 5.1 years). Successful removal of permanent IVC filters was possible in 11 of 12 patients (91.6 %). In 1 patient, a chronically thrombosed IVC filter could not be removed despite laser sheath assistance, but was successfully recanalized with the PowerWire RF guidewire. In the failed retrieval attempt, a stent was placed through the chronically thrombosed IVC filter with restoration of in-line flow. One major complication of large venous groin hematoma was encountered.ConclusionsIn carefully selected patients, percutaneous removal of permanent IVC filters can be performed safely despite prolonged filter dwell times. Extraction of chronically embedded permanent IVC filters may be facilitated by jugular and femoral approaches, often with laser sheath assistance. Chronic filter thrombosis and caval scarring may increase the risk of retrieval failure.

  9. Percutaneous Retrieval of Permanent Inferior Vena Cava Filters

    Energy Technology Data Exchange (ETDEWEB)

    Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu; Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu; Holly, Brian, E-mail: bholly3@jhmi.edu [Johns Hopkins University School of Medicine, Division of Vascular & Interventional Radiology (United States); Bhagat, Nikhil, E-mail: nikhibhagat@gmail.com [Kaiser Permanente, Division of Vascular & Interventional Radiology (United States); Marx, Jonathan K., E-mail: jmarx9@jhmi.edu [Johns Hopkins University School of Medicine, Division of Vascular & Interventional Radiology (United States); Streiff, Michael, E-mail: mstreif@jhmi.edu [Johns Hopkins University School of Medicine, Department of Hematology (United States); Lessne, Mark L., E-mail: mlessne@gmail.com [Johns Hopkins University School of Medicine, Division of Vascular & Interventional Radiology (United States)

    2016-04-15

    PurposeTo evaluate the feasibility, risks, and techniques of percutaneous removal of permanent TrapEase and Simon Nitinol IVC filters.Materials and MethodsBetween August 2011 and August 2015, 12 patients (5 women, 7 men; age range, 26–75 years) underwent an attempt at percutaneous removal of permanent TrapEase (10) and Simon Nitinol (2) IVC filters due to a history of IVC filter complications or need for lifelong anticoagulation due to the filter. Medical records were reviewed for filter dwell time, presence of iliocaval deep venous thrombosis, procedural technique, and complications.ResultsFilter dwell times ranged from 7 days to 15 years (mean 5.1 years). Successful removal of permanent IVC filters was possible in 11 of 12 patients (91.6 %). In 1 patient, a chronically thrombosed IVC filter could not be removed despite laser sheath assistance, but was successfully recanalized with the PowerWire RF guidewire. In the failed retrieval attempt, a stent was placed through the chronically thrombosed IVC filter with restoration of in-line flow. One major complication of large venous groin hematoma was encountered.ConclusionsIn carefully selected patients, percutaneous removal of permanent IVC filters can be performed safely despite prolonged filter dwell times. Extraction of chronically embedded permanent IVC filters may be facilitated by jugular and femoral approaches, often with laser sheath assistance. Chronic filter thrombosis and caval scarring may increase the risk of retrieval failure.

  10. Simultaneous blunt traumatic laceration of inferior vena cava and ...

    African Journals Online (AJOL)

    A 30-year-old man who had been involved in a road traffic acci- dent underwent a computed tomography (CT) ... right renal artery also showed abrupt cut-off just distal to its ori- gin. The patient was managed conservatively as ... laceration of the IVC and the right renal artery is a catastrophic situation and can present a tough ...

  11. Vessel Wall Reaction after Vena Cava Filter Placement

    International Nuclear Information System (INIS)

    Hoekstra, Arend; Elstrodt, Jan M.; Nikkels, Peter G.J.; Tiebosch, Anton T.M.G.

    2002-01-01

    Purpose: To evaluate the interaction between the Cordis Keeper vena caval filter and vessel wall in aporcine model.Methods: Implantation of the filter was performed in five pigs. Radiologic data concerning inferior vena cava(IVC) diameter and filter patency, filter leg span, and stability were collected. At 2 or 6 months post-implantation, histopathologic analysis of the IVC wall was performed.Results: All filters remained patent with no evidence of migration. However, at 6 months follow-up, two legs of one filter penetrated the vessel wall and were adherent to the liver. These preliminary results suggest that with the observed gradual increase in the filter span, the risk of caval wall penetration increases with time, especially in a relatively small IVC(average diameter 16 mm).Conclusion: The Cordis Keeper filter was well tolerated, but seems to be prone to caval wall penetration in the long term

  12. Modeling Flow Past a Tilted Vena Cava Filter

    Energy Technology Data Exchange (ETDEWEB)

    Singer, M A; Wang, S L

    2009-06-29

    Inferior vena cava filters are medical devices used to prevent pulmonary embolism (PE) from deep vein thrombosis. In particular, retrievable filters are well-suited for patients who are unresponsive to anticoagulation therapy and whose risk of PE decreased with time. The goal of this work is to use computational fluid dynamics to evaluate the flow past an unoccluded and partially occluded Celect inferior vena cava filter. In particular, the hemodynamic response to thrombus volume and filter tilt is examined, and the results are compared with flow conditions that are known to be thrombogenic. A computer model of the filter inside a model vena cava is constructed using high resolution digital photographs and methods of computer aided design. The models are parameterized using the Overture software framework, and a collection of overlapping grids is constructed to discretize the flow domain. The incompressible Navier-Stokes equations are solved, and the characteristics of the flow (i.e., velocity contours and wall shear stresses) are computed. The volume of stagnant and recirculating flow increases with thrombus volume. In addition, as the filter increases tilt, the cava wall adjacent to the tilted filter is subjected to low velocity flow that gives rise to regions of low wall shear stress. The results demonstrate the ease of IVC filter modeling with the Overture software framework. Flow conditions caused by the tilted Celect filter may elevate the risk of intrafilter thrombosis and facilitate vascular remodeling. This latter condition also increases the risk of penetration and potential incorporation of the hook of the filter into the vena caval wall, thereby complicating filter retrieval. Consequently, severe tilt at the time of filter deployment may warrant early clinical intervention.

  13. Incidental right Bochdalek hernia with interruption of the inferior ...

    African Journals Online (AJOL)

    2014-05-30

    May 30, 2014 ... Case Report doi:10.4102/sajr.v18i1.592 http://sajr.org.za. Incidental right Bochdalek hernia with interruption of the inferior vena cava and hepatic venous collateral continuation: A case report. Authors: Farzanah I. Ismail1. Rule Human2. Anith Chacko1. Parmanand Naran2. Samia Ahmad1. Siraj Ellemdin2.

  14. Percutaneous transhepatic cholangiography: analysis of 120 cases

    International Nuclear Information System (INIS)

    Sohn, Hyung Sun; Shin, Kyung Sub; Kang, Hyo Seok

    1981-01-01

    Percutaneous transhepatic cholangiography (PTC) is of value in differential diagnosis of cholestatic diseases. Authors had performed PTC in 120 patients with flexible needle of 23 gauge at the Department of Radiology, Kang Nam St. Mary's Hospital and Myung Dong St. Mary's Hospital during the period from January, 1976 to April, 1980. PTC was accomplished successfully in 112 of 120 patients. Diagnoses included cholangiocarcinomas (27 cases), carcinomas of pancreas head (21 cases), ampullary carcinomas (4 cases), metastatic carcinomas (5 cases), bile duct stones (27 cases), sclerosing cholangitis (6 cases), hepatitis (6 cases), liver cirrhosis (6 cases), post operative adhesions (5 cases), chronic pancreatitis (3 cases), stomach carcinomas (3 cases), clonorchiasis (2 cases), blood clot (1 case), and remaining normal 4 cases. Some characteristic PTC findings were: (1) segmental annular narrowing and abrupt complete obstruction and polyploid filling defects of the bile duct in cholangiocarcinoma, (2) typical nipple or rat-tail appearance of the distal common bile duct in pancreatic head carcinoma, (3) single or multiple sharply and smoothly outlined filling defects within bile duct in all cases of stones, (4) complete obstruction with shallow concavity in ampullary carcinoma, (5) diffuse or segmental narrowing of the intrahepatic bile duct and common bile duct in sclerosing cholangitis, (6) multiple tiny polypoid filling defects of gall bladder, common hepatic duct, and common bile duct in clonorchiasis. (7) normal appearance in hepatitis. The overall diagnostic accuracy of PTC in 66 operated cases was 89.4%, and complications following the examination were significantly reduced by using a fine flexible needle (23 gauge). From the present study it is concluded as follows: 1. To evaluate obstructed or stenosed site accurately, aspiration of bile juice must be preceded by a 23 gauge needle connected to either 10 ml or 5 ml syringe. 2. To diagnose carcinoma of the

  15. A case of residual inferior sinus venosus defect after ineffective surgical closure.

    Science.gov (United States)

    Uga, Sayuri; Hidaka, Takayuki; Takasaki, Taiichi; Kihara, Yasuki

    2014-10-03

    A 38-year-old woman presented with cyanosis and heart failure 34 years after patch closure of an atrial septal defect and partial anomalous pulmonary venous connection. CT and cardiac catheterisation showed a residual defect that caused right-to-left shunting. The patch almost blocked the inferior vena cava from the right atrium, resulting in uncommon drainage of the inferior vena cava into the left atrium. Other anomalies included the coronary-to-pulmonary artery fistula and duplicate inferior vena cava with dilated azygos venous system. A second surgery was performed, and we confirmed an inferior sinus venosus defect, which is rare and can be misdiagnosed. The ineffective patch closure had caused a haemodynamic status that rarely occurs. We describe the diagnostic process and emphasise the importance of correctly understanding the entity. 2014 BMJ Publishing Group Ltd.

  16. Monorail system for percutaneous repositioning of the Greenfield vena caval filter.

    Science.gov (United States)

    Guthaner, D F; Wyatt, J O; Mehigan, J T; Wright, A M; Breen, J F; Wexler, L

    1990-09-01

    The authors describe a technique for removing or repositioning a malpositioned Greenfield inferior vena caval filter. A "monorail" system was used, in which a wire was passed from the femoral vein through the apical hole in the filter and out the internal jugular vein; the wire was held taut from above and below and thus facilitated repositioning or removal of the filter. The technique was used successfully in two cases.

  17. Primitive neuroectodermal tumour of the kidney with vena caval and atrial tumour thrombus: a case report

    Directory of Open Access Journals (Sweden)

    Ong Poh

    2008-08-01

    Full Text Available Abstract Introduction Renal primitive neuroectodermal tumour is an extremely rare malignancy. Case presentation A 21-year-old woman presented with microscopic haematuria, a palpable right loin mass, dyspnoea, dizziness and fatigue. Initial ultrasound scan of the kidneys revealed an 11 cm right renal mass with venous extension into the inferior vena cava. Computed tomography of the thorax and abdomen revealed an extension of the large renal mass into the right renal vein, inferior vena cava and up to the right atrium. A small paracaval lymph node was noted and three small metastatic nodules were identified within the lung parenchyma. The patient underwent a radical nephrectomy and inferior vena caval tumour (level IV thrombectomy with cardiopulmonary bypass and deep hypothermic circulatory arrest. Immunohistochemical staining of the specimen showed a highly specific cluster of differentiation (CD 99, thus confirming the diagnosis of a primitive neuroectodermal tumour. Conclusion It is important that a renal primitive neuroectodermal tumour be considered, particularly in young patients with a renal mass and extensive thrombus.

  18. Hepatic vena cava syndrome: New concept of pathogenesis.

    Science.gov (United States)

    Shrestha, Santosh Man; Kage, Masayoshi; Lee, Byung Boong

    2017-06-01

    Hepatic vena cava syndrome, also known as membranous obstruction of inferior vena cava (IVC), was considered a rare congenital disease and classified under Budd-Chiari syndrome. It is now recognized as a bacterial infection-induced disease related to poor hygiene. Localized thrombophlebitis of the IVC at the site close to hepatic vein outlets is the initial lesion which converts on resolution into stenosis or complete obstruction, the circulatory equilibrium being maintained by development of cavo-caval collateral anastomosis. These changes persist for the rest of the patient's life. The patient remains asymptomatic for a variable period until acute exacerbations occur, precipitated by bacterial infection, resulting in deposition of thrombi at the site of the lesion and endophlebitis in intrahepatic veins. Large thrombus close to hepatic vein outlets results in ascites from hepatic venous outflow obstruction, which is followed by development of venocentric cirrhosis. Endophlebitis of intrahepatic veins results in ischemic liver damage and development of segmental stenosis or membrane. Acute exacerbations are recognized clinically as intermittent jaundice and/or elevation of aminotransferase or ascites associated with neutrophil leukocytosis and elevation of C-reactive protein; sonologically, they are recognized as the presence of thrombi of different ages in IVC and thrombosis of intrahepatic veins. Development of liver cirrhosis and hepatocellular carcinoma is related to severity or frequency of acute exacerbations and not to duration or type of caval obstruction. Hepatic vena cava syndrome is a common co-morbid condition with other liver diseases in developing countries and it should be considered in differential diagnosis in patient with intermittent elevation serum bilirubin and or aminotransferase or development of ascites and cirrhosis. © 2017 The Japan Society of Hepatology.

  19. Design Optimization of Vena Cava Filters: An application to dual filtration devices

    Energy Technology Data Exchange (ETDEWEB)

    Singer, M A; Wang, S L; Diachin, D P

    2009-12-03

    Pulmonary embolism (PE) is a significant medical problem that results in over 300,000 fatalities per year. A common preventative treatment for PE is the insertion of a metallic filter into the inferior vena cava that traps thrombi before they reach the lungs. The goal of this work is to use methods of mathematical modeling and design optimization to determine the configuration of trapped thrombi that minimizes the hemodynamic disruption. The resulting configuration has implications for constructing an optimally designed vena cava filter. Computational fluid dynamics is coupled with a nonlinear optimization algorithm to determine the optimal configuration of trapped model thrombus in the inferior vena cava. The location and shape of the thrombus are parameterized, and an objective function, based on wall shear stresses, determines the worthiness of a given configuration. The methods are fully automated and demonstrate the capabilities of a design optimization framework that is broadly applicable. Changes to thrombus location and shape alter the velocity contours and wall shear stress profiles significantly. For vena cava filters that trap two thrombi simultaneously, the undesirable flow dynamics past one thrombus can be mitigated by leveraging the flow past the other thrombus. Streamlining the shape of thrombus trapped along the cava wall reduces the disruption to the flow, but increases the area exposed to abnormal wall shear stress. Computer-based design optimization is a useful tool for developing vena cava filters. Characterizing and parameterizing the design requirements and constraints is essential for constructing devices that address clinical complications. In addition, formulating a well-defined objective function that quantifies clinical risks and benefits is needed for designing devices that are clinically viable.

  20. Percutaneous transhepatic biliary drainage: analysis of 175 cases

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kyung Jin; Lee, Sang Kwon; Kim, Tae Hun; Kim, Yong Joo; Kang, Duk Sik [College of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    1990-10-15

    Percutaneous transhepatic biliary drainage is a safe, effective and palliative means of treatment in biliary obstruction, especially in cases with malignant obstruction which are inoperable. 175 cases of transhepatic biliary drainage were performed on 119 patients with biliary obstruction from January 1985 to June 1989 at Kyung-pook National University Hospital. The causes of obstructive jaundice were 110 malignant diseases and 9 benign diseases. The most common indication for drainage was palliative intervention of obstruction secondary to malignant tumor in 89 cases. 86 cases of external drainage were performed including 3 cases of left duct approach, 29 cases of external-internal drainage and 60 cases of endoprosthesis. In external and external-internal drainages, immediate major complications (11.9%) occurred, including not restricted to, but sepsis, bile peritonitis and hemobilia. Delayed major complications (42.9%) were mainly catheter related. The delayed major complication of endoprosthesis resulted from obstruction of the internal stent. The mean time period to reobstruction of the internal stent was about 12 weeks. To improve management status, regular follow-up is required, as is education of both patients and their families as to when immediate clinical attention is mandated. Close communication amongst the varying medical specialities involved will be necessary to provide optional treatment for each patient.

  1. Percutaneous transhepatic biliary drainage: analysis of 175 cases

    International Nuclear Information System (INIS)

    Suh, Kyung Jin; Lee, Sang Kwon; Kim, Tae Hun; Kim, Yong Joo; Kang, Duk Sik

    1990-01-01

    Percutaneous transhepatic biliary drainage is a safe, effective and palliative means of treatment in biliary obstruction, especially in cases with malignant obstruction which are inoperable. 175 cases of transhepatic biliary drainage were performed on 119 patients with biliary obstruction from January 1985 to June 1989 at Kyung-pook National University Hospital. The causes of obstructive jaundice were 110 malignant diseases and 9 benign diseases. The most common indication for drainage was palliative intervention of obstruction secondary to malignant tumor in 89 cases. 86 cases of external drainage were performed including 3 cases of left duct approach, 29 cases of external-internal drainage and 60 cases of endoprosthesis. In external and external-internal drainages, immediate major complications (11.9%) occurred, including not restricted to, but sepsis, bile peritonitis and hemobilia. Delayed major complications (42.9%) were mainly catheter related. The delayed major complication of endoprosthesis resulted from obstruction of the internal stent. The mean time period to reobstruction of the internal stent was about 12 weeks. To improve management status, regular follow-up is required, as is education of both patients and their families as to when immediate clinical attention is mandated. Close communication amongst the varying medical specialities involved will be necessary to provide optional treatment for each patient

  2. Transcutaneous transhepatic portography in the diagnosis of neoplasms of the organs of the hepatopancreatoduodenal zone

    International Nuclear Information System (INIS)

    Savel'ev, V.S.; Prokubovskij, V.I.; Kapranov, S.A.

    1987-01-01

    An analysis of the results of 135 transcutaneous transhepatic investigations of the venous system including 39 superselective investigations of the pancreatoduodenal veins conducted in 78 patients with different diseases of the organs of the hepatopancreatodoudenal zone, made it possible to describe in detail and systematize their phlebographic semiotics. The diagnostic accuracy of the transhepatic radiopaque investigation of the portal vein in pancreatic diseases was 96.5%, in tumors of the biliary tract - 89.5%. The results of transcutaneous transhepatic portography formed the basis for the determination of a size of lesion and applicability of surgery in blastomatous involvement of the organs of the hepatopancreatoduodenal zone

  3. Persistent left superior vena cava with absent right superior vena cava: image findings

    International Nuclear Information System (INIS)

    Araujo Junior, Cyrillo Rodrigues de; Carvalho, Tarcisio Nunes; Fraguas Filho, Sergio Roberto; Costa, Marlos Augusto Bitencourt; Jacob, Beatriz Mahmud; Machado, Marcio Martins; Teixeira, Kim-Ir-Sen Santos; Ximenes, Carlos Alberto

    2003-01-01

    Persistent left superior vena cava absent right superior vena cava is a rare anomaly, with less than 150 cases reported in the literature. Congenitally persistent left superior vena cava is the most common variant of systemic venous return to the heart, resulting embryologically from failure of the left anterior cardinal vein to become obliterated. Its incidence varies from 0.3% in patients with otherwise normal heart to 4.3% in patients with congenital heart disease. In the majority of the patients, a right superior vena cava is present as well, but rarely the right anterior cardinal vein degenerates resulting in the absence of the normal right superior vena cava. The blood from the right side is carried by the persistent left superior vena cava to the right atrium through the coronary sinus. We report the case of a patient with a persistent left superior vena cava and absence of right superior vena cava identified by chance during a chest radiograph and computed tomography examination for investigation of chronic pulmonary obstructive disease. The patient had no congenital heart disease and the blood from the right side was drained by the persistent left superior vena cava into the right atrium through the coronary sinus. (author)

  4. Simon nitinol vena cava filters: effectiveness and complications

    International Nuclear Information System (INIS)

    Wolf, F.; Thurnher, S.; Lammer, J.

    2001-01-01

    Purpose: The aim of this retrospective analysis was to evaluate the clinical safety and effectiveness of the simon nitinol inferior vena cava filter (SNF) for prevention of pulmonary embolism. Patients and Methods: 117 patients (63 male, 54 female; aged 58.38 ± 14.59 years) underwent percutaneous implantation of an SNF from 1993 through 1999. Patient reports were retrospectively analysed for complications during and after implantation and deep venous thrombosis (DVT) and pulmonary embolism before and after implantation. Helical-CT with contrast media and plain abdominal radiography were performed on 35 patients, helical-CT alone on two patients. We checked the position and configuration of the SNF and looked for a perforation of the filter legs through the wall of the inferior vena cava (IVC). The IVC and deep pelvic veins were analysed for patency. Results: During implantation 10 of 117 (9%) patients had minor complications, major complications were reported in 0.9% (1/117). There was no significant increase in thrombosis of the deep pelvic veins and the IVC after implantation. Pulmonary re-embolism (PE) was documented in 9 out of 117 patients (7.7%). One out of the 35 examined patients (2.9%) showed a single strut fracture of the SNF. Tilting more than 15 was seen in 7 out of 37 patients (19%). Dislocation of the SNF more than 10 mm occurred in one out of 35 patients (2.9%), perforation through the wall of the IVC in all 37 patients. We found no occlusion of the IVC. (orig.) [de

  5. Early and Late Retrieval of the ALN Removable Vena Cava Filter: Results from a Multicenter Study

    International Nuclear Information System (INIS)

    Pellerin, O.; Barral, F. G.; Lions, C.; Novelli, L.; Beregi, J. P.; Sapoval, M.

    2008-01-01

    Retrieval of removable inferior vena cava (IVC) filters in selected patients is widely practiced. The purpose of this multicenter study was to evaluate the feasibility and results of percutaneous removal of the ALN removable filter in a large patient cohort. Between November 2003 and June 2006, 123 consecutive patients were referred for percutaneous extraction of the ALN filter at three centers. The ALN filter is a removable filter that can be implanted through a femoral/jugular vein approach and extracted by the jugular vein approach. Filter removal was attempted after an implantation period of 93 ± 15 days (range, 6-722 days) through the right internal jugular vein approach using the dedicated extraction kit after control inferior vena cavography. Following filter removal, vena cavograms were obtained in all patients. Successful extraction was achieved in all but one case. Among these successful retrievals, additional manipulation using a femoral approach was needed when the apex of the filter was close to the IVC wall in two patients. No immediate IVC complications were observed according to the postimplantation cavography. Neither technical nor clinical differences between early and late filter retrieval were noticed. Our data confirm the safety of ALN filter retrieval up to 722 days after implantation. In infrequent cases, additional endovenous filter manipulation is needed to facilitate extraction.

  6. Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes

    International Nuclear Information System (INIS)

    Hoffer, Eric K.; Mueller, Rebecca J.; Luciano, Marcus R.; Lee, Nicole N.; Michaels, Anne T.; Gemery, John M.

    2013-01-01

    PurposeTo evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter.MethodsA retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59 % were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86 % of patients; 14 % were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records.ResultsMean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3 %). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4 %). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8 %) at a mean of 731 days revealed a single (0.3 %) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5 %), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4 %) at a mean 757 days.ConclusionThe Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters

  7. Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, Eric K., E-mail: eric.k.hoffer@hitchcock.org; Mueller, Rebecca J.; Luciano, Marcus R.; Lee, Nicole N.; Michaels, Anne T.; Gemery, John M. [Dartmouth-Hitchcock Medical Center, Department of Radiology, Section of Vascular and Interventional Radiology (United States)

    2013-08-01

    PurposeTo evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter.MethodsA retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59 % were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86 % of patients; 14 % were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records.ResultsMean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3 %). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4 %). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8 %) at a mean of 731 days revealed a single (0.3 %) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5 %), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4 %) at a mean 757 days.ConclusionThe Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.

  8. Safety and efficacy of the Gunther Tulip retrievable vena cava filter: midterm outcomes.

    Science.gov (United States)

    Hoffer, Eric K; Mueller, Rebecca J; Luciano, Marcus R; Lee, Nicole N; Michaels, Anne T; Gemery, John M

    2013-08-01

    To evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter. A retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59% were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86% of patients; 14% were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records. Mean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3%). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4%). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8%) at a mean of 731 days revealed a single (0.3%) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5%), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4%) at a mean 757 days. The Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.

  9. Retrievable Vena Cava Filters in Major Trauma Patients: Prevalence of Thrombus Within the Filter

    International Nuclear Information System (INIS)

    Mahrer, Arie; Zippel, Douglas; Garniek, Alexander; Golan, Gil; Bensaid, Paul; Simon, Daniel; Rimon, Uri

    2008-01-01

    The purpose of this study was to report the prevalence of thrombus within a retrievable vena cava filter inserted prophylactically in major trauma patients referred for filter extraction. Between November 2002 and August 2005, 80 retrievable inferior vena cava filters (68 Optease and 12 Gunther-Tulip) were inserted into critically injured trauma patients (mean injury severity score 33.5). The filters were inserted within 1 to 6 (mean 2) days of injury. Thirty-seven patients were referred for filter removal (32 with Optease and 5 with Gunther-Tulip). The indwelling time was 7 to 22 (mean 13) days. All patients underwent inferior vena cavography prior to filter removal. There were no insertion-related complications and all filters were successfully deployed. Forty-three (54%) of the 80 patients were not referred for filter removal, as these patients continued to have contraindications to anticoagulation. Thirty-seven patients (46%) were referred for filter removal. In eight of them (22%) a large thrombus was seen within the filters and they were left in place, all with the Optease device. The other 29 filters (36%) were removed uneventfully.We conclude that the relatively high prevalence of intrafilter thrombi with the Optease filter may be explained by either spontaneous thrombus formation or captured emboli.

  10. Percutaneous transhepatic fragmentation of gall stones and extraction of fragments

    International Nuclear Information System (INIS)

    Guenther, R.; Klose, K.; Schmidt, H.D.; Staritz, M.; Mainz Univ.; Mainz Univ.

    1983-01-01

    Attempts at percutaneous removal have been made in 13 patients with solitary and multiple intra- and extra-hepatic biliary duct stones measuring 5 to 30 mm. The stones were fragmented with a Dormia basket and the fragments removed transhepatically. In ten patients the procedure was successful, including one patient with multiple intra-hepatic stones. The procedure can be recommended for cases of calculous obstruction of biliary anastomoses or of stones which could not be removed by endoscopy, or where there is already biliary drainage being carried out, or in patients with a high opertive risk. In two patients, dilatation of the papilla was also carried out, in four patients a stenosis was dilated and in a further two patients, electro-incision of a stenosis was performed. (orig.) [de

  11. The superior vena cava syndrome caused by malignant disease

    International Nuclear Information System (INIS)

    Eren, Suat; Karaman, Adem; Okur, Adnan

    2006-01-01

    blood flow was drained into both inferior vena cava and hemiazygos vein with the left renal vein. Conclusion: Multi-detector row CT with multiplanar and 3D imaging is an effective tool in evaluation of the SVCS and has a greater advantage than the other imaging techniques. 3D volume rendering is a useful technique in determining and describing collateral circulations in addition to the primary disease process

  12. The superior vena cava syndrome caused by malignant disease

    Energy Technology Data Exchange (ETDEWEB)

    Eren, Suat [Department of Radiology, Faculty of Medicine, Atatuerk University, 25240 Erzurum (Turkey)]. E-mail: suateren@atauni.edu.tr; Karaman, Adem [Department of Radiology, Faculty of Medicine, Atatuerk University, 25240 Erzurum (Turkey); Okur, Adnan [Department of Radiology, Faculty of Medicine, Atatuerk University, 25240 Erzurum (Turkey)

    2006-07-15

    blood flow was drained into both inferior vena cava and hemiazygos vein with the left renal vein. Conclusion: Multi-detector row CT with multiplanar and 3D imaging is an effective tool in evaluation of the SVCS and has a greater advantage than the other imaging techniques. 3D volume rendering is a useful technique in determining and describing collateral circulations in addition to the primary disease process.

  13. Vena cava superior syndrome associated with sarcoidosis

    International Nuclear Information System (INIS)

    Wurm, K.; Walz, M.; Reidemeister, J.C.; Donhuijsen, K.

    1988-01-01

    We report the first observation of clinical manifestations of vena cava superior syndrome (VCSS) associated with sarcoidosis. Twenty-four years after the first signs of the disease had been noted, mediastinal lymphomas penetrating the wall of the vena cava superior caused complete obstruction. It is most unusual for the vessel wall to be destroyed in this way, which explains why VCSS is often missed in sarcoidosis. The obstructed vessel was resected and successfully replaced by a Gore-Tex prosthesis. The importance of VCSS for the differential diagnosis is pointed out. Two further peculiarities are the simultaneous occurrence of elevated intraocular pressure and VCSS, and the familial incidence. (orig.) [de

  14. A radiologic evaluation of obstructive jaundice using percutaneous transhepatic cholangiography

    International Nuclear Information System (INIS)

    Schim, G. T.; Kim, T. H.; Zeon, S. K.; Ra, W. Y.

    1980-01-01

    Percutaneous transhepatic cholangiography (P.T.C.) is a most valuable procedure in differentiation of obstructive jaundice, whether benign (chiefly stone) or malignant condition. Authors present the clinical and P.T.C. findings of 30 cases of obstructive jaundice which were experienced from December 1975 to May 1977, at Department of Radiology, Kyung Pook National University Hospital. The summarized results were as follows. 1. The incidence of malignancy beyond the age of 40 was high compared with stone, which revealed relatively equal age distribution. 2. The stone showed as concave cupping in all cases (11 cases), but the malignancy showed as nipple formation (10 cases) and irregular narrowings (9 cases). 3. The dilation of the intrahepatic bile duct appeared 10 cases on malignancy among 19 cases of malignancy (52.6%) and 4 caes on stone which were multiple intrahepatic or common hepatic duct stones. 4. The dilation of the justproximal bile duct was severe on malignancy compared with stone. 5. The mean bilirubin level was high on malignancy (12.8 mg-%) compared with stone (10.3 mg-%).

  15. Early versus delayed laparoscopic cholecystectomy after percutaneous transhepatic gallbladder drainage.

    Science.gov (United States)

    Han, In Woong; Jang, Jin-Young; Kang, Mee Joo; Lee, Kyoung Bun; Lee, Seung Eun; Kim, Sun-Whe

    2012-03-01

    Percutaneous transhepatic gallbladder drainage (PTGBD) is a procedure to resolve acute cholecystitis (AC). It may decrease the technical difficulty of laparoscopic cholecystectomy (LC) and thus may facilitate successful surgery when a patients' condition improves. However, the timing of LC after PTGBD remains controversial. From 2004 to 2010, cholecystectomy after PTGBD was performed in 67 patients with AC. Group I members underwent LC within 72 h of PTGBD (n = 21), whereas group II members underwent LC at more than 72 h after PTGBD (n = 46). The open conversion rate was similar in the two groups. The perioperative complication rate was higher in group I than in group II, but with marginal significance (19.0 vs. 4.3%; p = 0.07). Mean operative time was longer in group I than in group II (79.3 ± 25.3 vs. 53.7 ± 45.3 min; p = 0.02). However, overall hospital stay was shorter in group I than in group II, but with marginal significance (10.8 ± 4.5 vs. 14.7 ± 9.3 days; p = 0.08). Pros and cons were well balanced between the two groups. Decisions on the timing of cholecystectomy after PTGBD should be made based on considerations of patient condition, hospital facilities, and surgical experience.

  16. Thrombosis of right ovarian vein; Trombosis de la vena ovarica derecha

    Energy Technology Data Exchange (ETDEWEB)

    Forner, J.; Talens, A.; Flores, M.; Mendez, M. [Hospital General Universitario de Valencia. Valencia (Spain)

    2001-07-01

    Ovarian vein thrombosis is a rare postpartum complication (0.1%). It can be fatal, since it can lead to sepsis, pulmonary thromboembolisms and inferior vena cava or renal vein thrombosis. Computed tomography and magnetic resonance imaging are the techniques of choice for its diagnosis, while the value of ultrasound is limited due to its low sensitivity and specificity. We report the case of a woman who, during puerperium, developed thrombosis of right ovarian vein that presented clinical, ultrasonographic and computed tomographic features of appendicitis. We describe the radiological sings and stress the fact that this diagnosis should be suspected in puerperal women. (Author) 9 refs.

  17. Endovascular Repair of a Perforation of the Vena Caval Wall Caused by the Retrieval of a Gunther Tulip Filter After Long-Term Implantation

    International Nuclear Information System (INIS)

    Morishita, Hiroyuki; Yamagami, Takuji; Matsumoto, Tomohiro; Takeuchi, Yoshito; Sato, Osamu; Nishimura, Tsunehiko

    2011-01-01

    Symptomatic penetration of the inferior vena cava (IVC) wall reportedly occurs in 0.3% of patients in whom a filter has been implanted, and it causes injury to the adjacent structures (Bogue et al. in Pediatr Radiol 39(10):1110–1113, 1; Brzezinski et al. in Burns 32(5):640–643, 2). We succeeded in the endovascular repair of perforation of the IVC wall occurring during the retrieval of a penetrated Gunther tulip vena cava filter (Cook, Bjaeverskov, Denmark) after long-term implantation.

  18. Vena cava filter placement via the antecubital access: a report of 6 cases

    International Nuclear Information System (INIS)

    Yu Bo; Shi Weihao; He Qing; Wang Tieping; Wang Wei

    2008-01-01

    Objective: To study the methods and skill of vena cava filter placement via the antecubital access. Methods: Six patients with DVT (4 males and 2 females, mean age of 62) underwent vena cava filter placement via the antecubital access in Huashan Hospital from Oct. 2004 to May. 2006. The right basilic vein was punctured with the use of micropuncture technique. SNF(Simon nitinol filter, Bard)was inserted through its carrier into the 90-cm-long sheath. The filter was then deployed with a standard fashion in the IVC, 5 cm inferior to the renal vein. Results: The filter was once placed successfully in all six patients within average time of 25 min without complications, but with good healing, exclusion of bleeding and no phlebitis. The position of filter was accurate without deviation and no occurrence of pulmonary embolism. Conclusions: vena cava filter placement via antecubital access is easy, minimal invasive, no need of lying in bed postoperatively. It is beneficial for DVT patients as an alternative for the contra-indication to femoral venous access. (authors)

  19. Percutaneous transhepatic cholangiographic forceps biopsy in pathologic diagnosis for obstructive jaundice

    International Nuclear Information System (INIS)

    Han Xinwei; Li Yongdong; Ma Bo; Xing Gusheng; Wu Gang; Gao Xuemei; Ma Nan

    2004-01-01

    Objective: To evaluate the technical feasibility and sensitivity of percutaneous transhepatic cholangiographic forceps biopsy in bile duct diseases. Methods: Between April 2001 and March 2003, 65 consecutive patients (36 men and 29 women; age range 33-88 years, mean 54 years) with obstructive jaundice underwent transluminal forceps biopsy or/and brush during percutaneous transhepatic cholangiography, percutaneous transhepatic cholangiography and drainage, or placement of stents. The technique was performed through an existing percutaneous transhepatic tract. Multiple specimens were obtained after passing the biopsy forceps or brush into a long 8-French sheath, and the specimens were fixed with formalin for pathologic or cytologic diagnosis. Statistical analysis was performed with the χ 2 test or Fisher exact probability, and P 2 =5.919, P=0.015). The cyctologic diagnosis was acquired in 43 of 58 patients with brush biopsy. Pathologic reports included cholangioadenocarcinoma (n=36), cholangiosquam-ocarcinoma (n=1), pancreatic adenocarcinoma (n=1), hepatocellular carcinoma (n=2), metastatic carcinoma (n=2), zoogloea aggregation (n=1), and negative results (n=15). The sensitivity rate of brush biopsy was 74.14%. Sensitivity of brush in the 45 patients with cholangiocarcinoma was higher than in the 11 patients with malignant tumors other than cholangiocarcinoma (82.22% vs 45.45%, χ 2 =4.563, P=0.033). Sensitivity of forceps biopsy in the 65 patients was higher than that of brush in the 58 patients (χ 2 =4.754, P=0.029). Conclusion: Percutaneous transhepatic cholangiobiopsy is a safe and minimal invasive procedure with no pain and low complication that is easy to perform with no addition trauma through a transhepatic biliary drainage tract. It is an effective, economic, accurate, and reliable new approach, which is safe and easy to perform in acquiring the pathologic diagnosis worthy to spread extensively. (authors)

  20. Obstructive jaundice: a comparative study of forceps and brush biopsy under percutaneous transhepatic cholangiography

    International Nuclear Information System (INIS)

    Li Yongdong; Han Xinwei; Wu Gang; Ma Bo; Xing Gusheng

    2004-01-01

    Objective: To compare the sensitivity between forceps biopsy and brushing, and to explore a feasible approach to pathological diagnosis of the obstructive jaundice. Methods: 92 consecutive patients with obstructive jaundice underwent transluminal forceps biopsy and brushing during percutaneous transhepatic cholangiography and percutaneous transhepatic cholangiodrainage. The technique was performed through a preexisting percutaneous transhepatic tract with multiple specimens obtained after passing the forceps biopsy or brush into a 8-French sheath. Finally the specimens were fixed with formalin for pathologic or cytologic diagnosis. Results: The histopathologic diagnosis was acquired in 81 out of 92 patients with forceps biopsy reaching the successful rate of 97.83%. Sensitivity of forceps biopsy in 92 patients was higher than that of brush in 84 patients (88.04% vs 76.19% χ 2 =4.251, P= <0.05). Conclusions: Percutaneous transhepatic cholangiobiopsy is a simple technique with minimal invasion, high sensitivity and worthy to be used spread extensively. Percutaneous transluminal brush cytology is also an useful method for establishing a diagnosis of cholangiocarcinoma. (authors)

  1. Uncommon Case of a Post-Traumatic Portal Vein Pseudoaneurysm Treated with Percutaneous Transhepatic Stent Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Ierardi, Anna Maria, E-mail: amierardi@yahoo.it [Uninsubria, Ospedale di Circolo, Interventional Radiology Unit (Italy); Berselli, Mattia, E-mail: mattia.berselli@ospedale.varese.it [Uninsubria, Ospedale di Circolo, Department of Surgery (Italy); Cuffari, Salvatore, E-mail: salvatore.cuffari@ospedale.varese.it [Uninsubria, Ospedale di Circolo, Anesthesiology Department (Italy); Castelli, Patrizio, E-mail: patrizio.castelli@uninsubria.it [Uninsubria, Ospedale di Circolo, Department of Vascular Surgery (Italy); Cocozza, Eugenio, E-mail: eugenio.cocozza@ospedale.varese.it [Uninsubria, Ospedale di Circolo, Department of Surgery (Italy); Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com [Uninsubria, Ospedale di Circolo, Interventional Radiology Unit (Italy)

    2016-10-15

    We describe a man who presented with a traumatic portal vein pseudoaneurysm, which was subsequently managed with a percutaneous transhepatic stent graft. This case demonstrates a rarely seen condition in the traumatic population and a novel management strategy, which should be considered in the management of this challenging injury.

  2. Fatal pericardial tamponade after superior vena cava stenting.

    NARCIS (Netherlands)

    Ploegmakers, M.J.M.; Rutten, M.J.C.M.

    2009-01-01

    We discuss a fatal complication of percutaneous superior vena cava (SVC) self-expandable stent placement in a patient with superior vena cava syndrome (SVCS). The SVCS was caused by a malignant mediastinal mass with total occlusion of the SVC. Twenty-four hours after the procedure, the patient died

  3. Ultrasound Detection of Superior Vena Cava Thrombus

    Directory of Open Access Journals (Sweden)

    Aaron Birch

    2014-09-01

    Full Text Available Superior vena cava (SVC syndrome is most commonly the insidious result of decreased vascular flow through the SVC due to malignancy, spontaneous thrombus, infections, and iatrogenic etiologies. Clinical suspicion usually leads to computed tomography to confirm the diagnosis. However, when a patient in respiratory distress requires emergent airway management, travel outside the emergency department is not ideal. With the growing implementation of point-of-care ultrasound (POCUS, clinicians may make critical diagnoses rapidly and safely. We present a case of SVC syndrome due to extensive thrombosis of the deep venous system cephalad to the SVC diagnosed by POCUS. [West J Emerg Med. 2014;15(6:715-718

  4. Extensive Left Iliac Veins and Inferior Vena Cava Thrombosis Revealing a Giant Uterine Myoma

    Directory of Open Access Journals (Sweden)

    Cărbunaru Ana

    2016-03-01

    Full Text Available A deep vein thrombosis was rarely associated with uterine myomas. Hereby, it is presented the case of a 40-year-old woman in which the clinical manifestation of the deep vein thrombosis revealed the further diagnosis of a large uterine myoma. The diagnosis, management and clinical outcome of the patient are emphasized and discussed. The management of a patient with a uterine myoma and deep vein thrombosis is challenging and implies a multidisciplinary team.

  5. Extensive Left Iliac Veins and Inferior Vena Cava Thrombosis Revealing a Giant Uterine Myoma.

    Science.gov (United States)

    Cărbunaru, Ana; Herlea; Ionescu, M; Dumitraşcu, T

    2016-01-01

    A deep vein thrombosis was rarely associated with uterine myomas. Hereby, it is presented the case of a 40-year-old woman in which the clinical manifestation of the deep vein thrombosis revealed the further diagnosis of a large uterine myoma. The diagnosis, management and clinical outcome of the patient are emphasized and discussed. The management of a patient with a uterine myoma and deep vein thrombosis is challenging and implies a multidisciplinary team.

  6. Rare case of left adrenal cortical carcinoma with level 3 inferior vena ...

    African Journals Online (AJOL)

    Observation: A 21-year-old male, incidentally detected with left supra renal tumor invading the left renal vein and the thrombus extending into the supra diaphragmatic IVC, underwent laparotomy with simultaneous median sternotomy on total cardiac bypass for removal of IVC tumor thrombus and radical excision of the ...

  7. Rare case of left adrenal cortical carcinoma with level 3 inferior vena ...

    African Journals Online (AJOL)

    K. Jain

    2017-05-02

    May 2, 2017 ... carcinoma with no renal parenchymal invasion and the immuno-histochemistry showing it to be positive for synaptophysin, inhibin and KI-67 (15%) while negative for chromogranin, pan cytokeratin and CD-10 receptors. Patient then received 3 weekly 6 cycles of adriamycin and cisplatin chemotherapy.

  8. Introducer Curving Technique for the Prevention of Tilting of Transfemoral Gunther Tulip Inferior Vena Cava Filter

    International Nuclear Information System (INIS)

    Xiao, Liang; Shen, Jing; Tong, Jia Jie; Huang, De Sheng

    2012-01-01

    To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters. The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval. The overall average ACF was 5.8 ± 4.14 degrees. In Group C, the average ACF was 7.1 ± 4.52 degrees. In Group T, the average ACF was 4.4 ± 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 ± 4.59 vs. 5.1 ± 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF ≥ 10 degree) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, X 2 = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, X 2 = 5.030, p = 0.025). The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting.

  9. Introducer Curving Technique for the Prevention of Tilting of Transfemoral Gunther Tulip Inferior Vena Cava Filter

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Liang; Shen, Jing; Tong, Jia Jie [The First Hospital of China Medical University, Shenyang (China); Huang, De Sheng [College of Basic Medical Science, China Medical University, Shenyang (China)

    2012-07-15

    To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters. The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval. The overall average ACF was 5.8 {+-} 4.14 degrees. In Group C, the average ACF was 7.1 {+-} 4.52 degrees. In Group T, the average ACF was 4.4 {+-} 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 {+-} 4.59 vs. 5.1 {+-} 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF {>=} 10 degree) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, X{sup 2} = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, X{sup 2} = 5.030, p = 0.025). The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting.

  10. Günther Tulip inferior vena cava filter retrieval using a bidirectional loop-snare technique.

    Science.gov (United States)

    Ross, Jordan; Allison, Stephen; Vaidya, Sandeep; Monroe, Eric

    2016-01-01

    Many advanced techniques have been reported in the literature for difficult Günther Tulip filter removal. This report describes a bidirectional loop-snare technique in the setting of a fibrin scar formation around the filter leg anchors. The bidirectional loop-snare technique allows for maximal axial tension and alignment for stripping fibrin scar from the filter legs, a commonly encountered complication of prolonged dwell times.

  11. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    International Nuclear Information System (INIS)

    Burcharth, F.; Aagaard, J.; Herlev Hospital

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P [de

  12. Percutaneous Transhepatic Removal of Bile Duct Stones: Results of 261 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ozcan, Nevzat, E-mail: nevzatcan@yahoo.com; Kahriman, Guven, E-mail: guvenkahriman@hotmail.com; Mavili, Ertugrul, E-mail: ertmavili@yahoo.com [Erciyes University, Department of Radiology, Medical Faculty (Turkey)

    2012-08-15

    Purpose: To determine the effectiveness of percutaneous transhepatic removal of bile duct stones when the procedure of endoscopic therapy fails for reasons of anatomical anomalies or is rejected by the patient. Methods: Between April 2001 and May 2010, 261 patients (138 male patients and 123 female patients; age range, 14-92 years; mean age, 64.6 years) with bile duct stones (common bile duct [CBD] stones = 248 patients and hepatolithiasis = 13 patients) were included in the study. Percutaneous transhepatic cholangiography was performed, and stones were identified. Percutaneous transhepatic balloon dilation of the papilla of Vater was performed. Then stones were pushed out into the duodenum with a Fogarty balloon catheter. If the stone diameter was larger than 15 mm, then basket lithotripsy was performed before balloon dilation. Results: Overall success rate was 95.7%. The procedure was successful in 97.5% of patients with CBD stones and in 61.5% of patients with hepatolithiasis. A total of 18 major complications (6.8%), including cholangitis (n = 7), subcapsular biloma (n = 4), subcapsular hematoma (n = 1), subcapsular abscess (n = 1), bile peritonitis (n = 1), duodenal perforation (n = 1), CBD perforation (n = 1), gastroduodenal artery pseudoaneurysm (n = 1), and right hepatic artery transection (n = 1), were observed after the procedure. There was no mortality. Conclusion: Our experience suggests that percutaneous transhepatic stone expulsion into the duodenum through the papilla is an effective and safe approach in the nonoperative management of the bile duct stones. It is a feasible alternative to surgery when endoscopic extraction fails or is rejected by the patient.

  13. Percutaneous Transhepatic Catheterization of the Portal Vein: A Combined CT- and Fluoroscopy-Guided Technique

    International Nuclear Information System (INIS)

    Weimar, Bernd; Rauber, Klaus; Brendel, Mathias D.; Bretzel, Reinhard G.; Rau, Wigbert S.

    1999-01-01

    Combined CT- and fluoroscopy-guided transhepatic portal vein catheterization was performed in 44 patients selected for pancreatic islet cell transplantation. The method allowed catheterization with a single puncture attempt in 39 patients. In four patients two attempts and in one patient four attempts were necessary. One minor hematoma of the liver capsule occurred that required no further treatment. Compared with other methods the average number of puncture attempts was reduced

  14. Percutaneous transhepatic sclerotherapy with embolization of the drainage vein for a gastric varix

    OpenAIRE

    Yoshimatsu, Rika; Yamagami, Takuji; Miura, Hiroshi; Okuda, Kotaro

    2014-01-01

    We experienced a case with a gastric varix that did not have a catheterizable main drainage vein and had multiple afferent veins. For this case we successfully performed percutaneous transhepatic sclerotherapy using the following procedure. After the drainage vein was embolized by metallic coils and n-butyl cyanoacrylate from a microcatheter that was advanced through the gastric varix, 5% ethanolamine oleate-iopamidol was infused into the gastric varix from one main afferent vein under balloo...

  15. Percutaneous Transhepatic Removal of Bile Duct Stones: Results of 261 Patients

    International Nuclear Information System (INIS)

    Ozcan, Nevzat; Kahriman, Guven; Mavili, Ertugrul

    2012-01-01

    Purpose: To determine the effectiveness of percutaneous transhepatic removal of bile duct stones when the procedure of endoscopic therapy fails for reasons of anatomical anomalies or is rejected by the patient. Methods: Between April 2001 and May 2010, 261 patients (138 male patients and 123 female patients; age range, 14–92 years; mean age, 64.6 years) with bile duct stones (common bile duct [CBD] stones = 248 patients and hepatolithiasis = 13 patients) were included in the study. Percutaneous transhepatic cholangiography was performed, and stones were identified. Percutaneous transhepatic balloon dilation of the papilla of Vater was performed. Then stones were pushed out into the duodenum with a Fogarty balloon catheter. If the stone diameter was larger than 15 mm, then basket lithotripsy was performed before balloon dilation. Results: Overall success rate was 95.7%. The procedure was successful in 97.5% of patients with CBD stones and in 61.5% of patients with hepatolithiasis. A total of 18 major complications (6.8%), including cholangitis (n = 7), subcapsular biloma (n = 4), subcapsular hematoma (n = 1), subcapsular abscess (n = 1), bile peritonitis (n = 1), duodenal perforation (n = 1), CBD perforation (n = 1), gastroduodenal artery pseudoaneurysm (n = 1), and right hepatic artery transection (n = 1), were observed after the procedure. There was no mortality. Conclusion: Our experience suggests that percutaneous transhepatic stone expulsion into the duodenum through the papilla is an effective and safe approach in the nonoperative management of the bile duct stones. It is a feasible alternative to surgery when endoscopic extraction fails or is rejected by the patient.

  16. Inferiority is compex

    Science.gov (United States)

    Wade, Jess

    2017-07-01

    In Inferior: How Science Got Women Wrong and the New Research That's Rewriting the Story, author Angela Saini puts forward the idea that bad science has been used to endorse the cultural prejudice that women are both biologically and psychologically second rate to men.

  17. Vena Cava Responsiveness to Controlled Isovolumetric Respiratory Efforts.

    Science.gov (United States)

    Folino, Anna; Benzo, Marco; Pasquero, Paolo; Laguzzi, Andrea; Mesin, Luca; Messere, Alessandro; Porta, Massimo; Roatta, Silvestro

    2017-10-01

    Respirophasic variation of inferior vena cava (IVC) size is affected by large variability with spontaneous breathing. This study aims at characterizing the dependence of IVC size on controlled changes in intrathoracic pressure. Ten healthy subjects, in supine position, performed controlled isovolumetric respiratory efforts at functional residual capacity, attaining positive (5, 10, and 15 mmHg) and negative (-5, -10, and -15 mmHg) alveolar pressure levels. The isovolumetric constraint implies that equivalent changes are exhibited by alveolar and intrathoracic pressures during respiratory tasks. The IVC cross-sectional area equal to 2.88 ± 0.43 cm 2 at baseline (alveolar pressure = 0 mmHg) was progressively decreased by both expiratory and inspiratory efforts of increasing strength, with diaphragmatic efforts producing larger effects than thoracic ones: -55 ± 15% decrease, at +15 mmHg of alveolar pressure (P < .01), -80 ± 33 ± 12% at -15 mmHg diaphragmatic (P < .01), -33 ± 12% at -15 mmHg thoracic. Significant IVC changes in size (P < .01) and pulsatility (P < .05), along with non significant reduction in the response to respiratory efforts, were also observed during the first 30 minutes of supine rest, detecting an increase in vascular filling, and taking place after switching from the standing to the supine position. This study quantified the dependence of the IVC cross-sectional area on controlled intrathoracic pressure changes and evidenced the stronger influence of diaphragmatic over thoracic activity. Individual variability in thoracic/diaphragmatic respiratory pattern should be considered in the interpretation of the respirophasic modulations of IVC size. © 2017 by the American Institute of Ultrasound in Medicine.

  18. Transhepatic Hilar Approach for Perihilar Cholangiocarcinoma: Significance of Early Judgment of Resectability and Safe Vascular Reconstruction.

    Science.gov (United States)

    Kuriyama, Naohisa; Isaji, Shuji; Tanemura, Akihiro; Iizawa, Yusuke; Kato, Hiroyuki; Murata, Yasuhiro; Azumi, Yoshinori; Kishiwada, Masashi; Mizuno, Shugo; Usui, Masanobu; Sakurai, Hiroyuki

    2017-03-01

    In the most common surgical procedure for perihilar cholangiocarcinoma, the margin status of the proximal bile duct is determined at the final step. Our procedure, the transhepatic hilar approach, confirms a cancer-negative margin status of the proximal bile duct first. We first performed a partial hepatic parenchymal transection to expose the hilar plate, and then transected the proximal bile duct to confirm margin status. Then, divisions of the hepatic artery and portal vein of the future resected liver are performed, followed by the residual hepatic parenchymal transection. The transhepatic hilar approach offers a wide surgical field for safe resection and reconstruction of the portal vein in the middle of the hepatectomy. We reviewed 23 patients with perihilar cholangiocarcinoma who underwent major hepatectomy using our procedure from 2011 to 2015. A combined vascular resection and reconstruction was carried out in 14 patients (60.9%). R0 resection was achieved in 17 patients (73.9%), and the overall 3-year survival rate was 52.9% (median survival time 52.4 months). The transhepatic hilar approach is useful and practicable regardless of local tumor extension, enabling us to determine tumor resectability and perform safe resection and reconstruction of the portal vein early in the operation.

  19. Single-stage intraoperative transhepatic biliary stenting in patients with unresectable hepatobiliary pancreatic tumors.

    Science.gov (United States)

    Iwasaki, Yoshimi; Kubota, Keiichi; Kita, Junji; Katoh, Masato; Shimoda, Mitsugi; Sawada, Tokihiko; Iso, Yukihiro

    2013-02-01

    The current study was conducted to evaluate the safety and utility of intraoperative transhepatic biliary stenting (ITBS) in patients with unresectable malignant biliary obstruction (UMBO) diagnosed intraoperatively. In this study, 50 patients who underwent ITBS for UMBO between April 2001 and May 2009 were retrospectively reviewed. For 26 patients who underwent preoperative percutaneous transhepatic biliary drainage (PTBD), the expandable metallic stent (EMS) was inserted intraoperatively by the PTBD route in a single stage. For 24 patients, the intrahepatic bile ducts were intentionally dilated by injection of saline via the endoscopic nasobiliary drainage or the percutaneous transhepatic gallbladder drainage route, and the puncture was performed under intraoperative ultrasound guidance followed by guidewire and catheter insertion. Thereafter, the EMS was placed in the same manner. The initial postoperative complications and long-term results of ITBS were evaluated. In all cases, ITBS was technically successful. Stenting alone was performed in 22 patients and stenting combined with other procedures in 28 patients. Hospital mortality occurred for three patients (6 %), and complication-related mortality occurred in two cases (4 %). There were nine cases (18 %) of postoperative complications. The median survival time was 179 days, and the EMS patency time was 137 days. During the follow-up period, EMS occlusion occurred in 23 cases (46 %). Best supportive care was a significant independent risk factor for early mortality within 100 days after ITBS (p = 0.020, odds ratio, 9.398). Single-stage ITBS is feasible for palliation of UMBO and seems to have a low complication rate.

  20. Placement of percutaneous transhepatic biliary stent using a silicone drain with channels

    Science.gov (United States)

    Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi

    2009-01-01

    This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159

  1. Interventional therapy of hepatic arterial hemorrhage occurred after percutaneous transhepatic biliary drainage

    International Nuclear Information System (INIS)

    Liang Songnian; Feng Bo; Su Hongying; Xu Ke

    2011-01-01

    Objective: To analyze the causes and clinical manifestations of hepatic arterial hemorrhage which occurred after percutaneous transhepatic biliary drainage and to summarize the practical experience in its diagnosis and treatment in order to decrease its incidence and mortality. Methods: During the period from June 2007 to June 2010, percutaneous transhepatic biliary drainage was carried out in 622 cases, of which DSA-proved postoperative hepatic arterial hemorrhage occurred in 11, including bile duct hemorrhage (n=6), abdominal cavity bleeding (n=3) and combination of bile duct and abdominal cavity (n=2). Interventional embolization of the bleeding branches of hepatic artery with Gelfoam and coils was carried out in all 11 patients. The clinical data such as clinical manifestations and therapeutic results were retrospectively analyzed. Results: After interventional embolization therapy for postoperative hepatic arterial hemorrhage the bleeding stopped in ten patients, who were discharged from hospital when the clinical conditions were alleviated. The remaining one patient died of sustained deterioration in hepatic and renal functions although the bleeding was ceased. Conclusion: Though hepatic arterial hemorrhage occurred after percutaneous transhepatic biliary drainage is a rare complication, it is dangerous and fatal. Hepatic arterial angiography together with interventional embolization is a sate and effective therapy for hepatic arterial hemorrhage. (authors)

  2. Ultrasound-guided percutaneous transhepatic biliary drainage: Experiences in 146 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jai Keun [Sohwa Children' s Hospital, Seoul(Korea, Republic of); Yu, Jeong Sik; Kim, Ki Whang; Chung, Soo Yoon; Jeong, Mi Gyoung [Yonsei University College of Medicine, Seoul (Korea, Republic of); Choi, Deuk Lin; Kwon, Gui Hyang; Lee, Hae Kyung [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1999-03-15

    Percutaneous biliary drainage is an important technique for palliative therapy of obstructive biliary disease and diagnostic information. The purpose of this study is to review and evaluate the experiences of ultrasound-guided percutaneous transhepatic biliary drainage. Ultrasound-guided percutaneous transhepatic biliary drainage was performed on 146 occasions in 134 patients. The causes of biliary obstruction were: benign diseases (19 cases, 14.2%) such as bile duct stones or stricture, cholangiocarcinoma (37 cases, 27.6%), pancreatic carcinoma (35 cases, 26.1%), metastasis (22 cases, 16.5%), gall bladder cancer (14 cases, 10.4%), ampulla of Vater cancer (4 cases, 3.0%), hepatocellular carcinoma (3 cases, 2.2%). Retrospectively reviewing medical records, we found out frequency of external or external/internal biliary drainages, puncture of left or right hepatic duct, and presence of bileinfection. Ultrasound-guided percutaneous transhepatic biliary drainage was compared with conventional biliary drainage of previous reports on the basis of frequency of complications. External (124 procedures, 84.9%) and external/internal biliary drainage (22 procedures, 15.1%) were carried out by puncture of dilated right (59.6%) or left (40.4%) intrahepatic duct. Sixty-nine complications occurred in 47 patients. Catheter related complications (33/69, 47.8%) were most common: catheter dislodgement (17/69, 24.6%), malfunction (9/69, 13.1%), leakage (7/69, 10.1%). Other minor complications such as simple fever (16/69, 23.2%), cholangitis (7/69, 10.1%), hemobilia (4/69, 5.8%), biloma (2/69, 2.9%) and wound infection (1/69, 1.5%) occurred. Major complications including sepsis (4/69, 5.8%) and bile peritonitis (2/69, 2.9%) were also noted. Puncture-related complications such as hemobilia, biloma and bile peritonitis occurred in 8 cases (5.5%). Comparing with conventional X-ray guided drainage, ultrasound-guided percutaneous transhepatic biliary drainage is a safe procedure for

  3. Right superior vena cava draining into the left atrium

    Energy Technology Data Exchange (ETDEWEB)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); Batisse, Alain [Institut de Puericulture et de Perinatalogie, Paris (France); Vouhe, Pascal [University Rene Descartes-Paris 5, Department of Paediatric Cardiac Surgery, Hopital Necker-Enfants Malades, Paris (France); Ou, Phalla [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); University Rene Descartes-Paris 5, Department of Pediatric Radiology, Hopital Necker-Enfants Malades, Paris (France)

    2008-08-15

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  4. Right superior vena cava draining into the left atrium

    International Nuclear Information System (INIS)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien; Batisse, Alain; Vouhe, Pascal; Ou, Phalla

    2008-01-01

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  5. Percutaneous transhepatic recanalization of malignant hilarobstruction: A possible rescue for early failure of endoscopic y-stenting

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hoon; Kim, Chang Won; Lee, Tae Hong; Kim, Dong Uk [Pusan National University School of Medicine, Pusan National University Hospital, Busan (Korea, Republic of); Jeon, Ung Bae; Kang, Dae Hwan [Pusan National University School of Medicine, Yangsan Pusan National University Hospital, Yangsan (Korea, Republic of)

    2013-11-15

    Endoscopic biliary stenting is well known as an optimal method of management of malignant hilar obstruction, but sometimes the result is not satisfactory, with early stent failure. Percutaneous transhepatic biliary drainage (PTBD) has a distinct advantage over endoscopic retrograde cholangiopancreatoscopy in that with ultrasound guidance one or more appropriate segments for drainage can be chosen. We evaluated the effectiveness of percutaneous transhepatic stenting as a rescue of early failure of endoscopic stenting. Ten patients (4 men, 6 women; age range, 52-78 years; mean age, 69 years) with inoperable biliary obstruction (2 patients with gall bladder cancer and hilar invasion, and 8 patients with Klatskin tumor) and with early endoscopic stent failure were included in our study. All of the patients underwent PTBD and percutaneous transhepatic biliary stenting. Metallic stents were placed in all patients for internal drainage. Percutaneous rescue stenting was successful in all the patients technically and clinically. Mean time for the development of biliary obstruction was 13.5 days after endoscopic stenting. The mean patency of the rescue stenting was 122 days. The mean survival time for percutaneous transhepatic rescue stenting was 226.3 days. In early failure of endoscopic biliary stenting, percutaneous transhepatic recanalization can be a possible solution.

  6. Percutaneous transhepatic recanalization of malignant hilarobstruction: A possible rescue for early failure of endoscopic y-stenting

    International Nuclear Information System (INIS)

    Kwon, Hoon; Kim, Chang Won; Lee, Tae Hong; Kim, Dong Uk; Jeon, Ung Bae; Kang, Dae Hwan

    2013-01-01

    Endoscopic biliary stenting is well known as an optimal method of management of malignant hilar obstruction, but sometimes the result is not satisfactory, with early stent failure. Percutaneous transhepatic biliary drainage (PTBD) has a distinct advantage over endoscopic retrograde cholangiopancreatoscopy in that with ultrasound guidance one or more appropriate segments for drainage can be chosen. We evaluated the effectiveness of percutaneous transhepatic stenting as a rescue of early failure of endoscopic stenting. Ten patients (4 men, 6 women; age range, 52-78 years; mean age, 69 years) with inoperable biliary obstruction (2 patients with gall bladder cancer and hilar invasion, and 8 patients with Klatskin tumor) and with early endoscopic stent failure were included in our study. All of the patients underwent PTBD and percutaneous transhepatic biliary stenting. Metallic stents were placed in all patients for internal drainage. Percutaneous rescue stenting was successful in all the patients technically and clinically. Mean time for the development of biliary obstruction was 13.5 days after endoscopic stenting. The mean patency of the rescue stenting was 122 days. The mean survival time for percutaneous transhepatic rescue stenting was 226.3 days. In early failure of endoscopic biliary stenting, percutaneous transhepatic recanalization can be a possible solution.

  7. Radiotherapy of superior vena cava syndrome

    International Nuclear Information System (INIS)

    Kawanami, Shoko; Imada, Hajime; Terashima, Hiromi; Nakata, Hajime

    1996-01-01

    The records of 38 patients with superior vena cava syndrome (SVC syndrome) due to malignancy and who received radiation therapy were retrospectively reviewed. The majority were lung cancers, constituting 28 of the 38 cases (73.7%). All patients were treated with conventional radiation doses ranging from 20 to 70 Gy and good symptomatic response was observed in 31 cases (81.6% ). The response appeared within 1.7±0.9 weeks on average (3 days-4 weeks;, and performance status also improved in 50% of the patients. The median survival was 6.6 months. Long term survivors were seen mostly in patients with thymoma, and only one patient ever showed a recurrence of SVC syndrome. We conclude that radiotherapy can be an effective therapeutic modality for SVC syndrome and that it improves the quality of life in most patients. (author)

  8. CT findings of superior vena cava syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jun; Lee, Jae Mun; Kim, Choon Yul; Bahk, Yong Whee [Catholic Medical College, Seoul (Korea, Republic of)

    1986-10-15

    Since early 1980's high resolution CT has been used for detection of intrathoracic pathologic condition such as superior vena cava syndrome. Authors retrospectively analysed CT findings of 18 cases of proven SVC syndrome. The results were as follows: 1. The mean age was 50-year-old, and 14 cases were male. 2. Of 18 cases of SVC syndrome, 8 cases had confirmed to be lung cancers, malignant thymoma and teratoma were respectively each 2 cases, and malignant lymphoma, mediastinal abscess, thyroid adenoma and metastatic tumor were 1 case. 3. CT findings were A. Abnormal SVC consisted of compression with displacement (44.4%), intraluminal thrombus (27.8%), and encasement (27.8%). B. The collateral pathways were the azygos-homozygous (88.8%), vertebral (50%), internal mammary (44.4%), and lateral thoracic route (33.3%)

  9. CT findings of superior vena cava syndrome

    International Nuclear Information System (INIS)

    Lim, Jun; Lee, Jae Mun; Kim, Choon Yul; Bahk, Yong Whee

    1986-01-01

    Since early 1980's high resolution CT has been used for detection of intrathoracic pathologic condition such as superior vena cava syndrome. Authors retrospectively analysed CT findings of 18 cases of proven SVC syndrome. The results were as follows: 1. The mean age was 50-year-old, and 14 cases were male. 2. Of 18 cases of SVC syndrome, 8 cases had confirmed to be lung cancers, malignant thymoma and teratoma were respectively each 2 cases, and malignant lymphoma, mediastinal abscess, thyroid adenoma and metastatic tumor were 1 case. 3. CT findings were A. Abnormal SVC consisted of compression with displacement (44.4%), intraluminal thrombus (27.8%), and encasement (27.8%). B. The collateral pathways were the azygos-homozygous (88.8%), vertebral (50%), internal mammary (44.4%), and lateral thoracic route (33.3%).

  10. Superior vena thrombosis with peripartum dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Munir, R.; Hussain, S.; Kayani, A.M.

    2014-01-01

    A 30 years multiparous female with history of emergency caesarean section 10 days back was referred to us with cough, severe breathlessness at rest, orthopnea with pain in neck and arms. Clinical examination revealed signs of heart failure. Echocardiography showed ejection fraction of 15%, with no right ventricular strain. A diagnosis of peripartum cardiomyopathy was made. Doppler ultrasound of neck veins showed bilateral internal jugular vein thrombosis. Subsequent multislice CT examination showed thrombosis of superior vena cava and both internal jugular veins (with collateral formation) and pulmonary embolism. There were no mediastinal abnormalities on the CT scan. Her thrombophilia screen and CT scan brain was normal. She was managed in collaboration with cardiologist. Following treatment with subcutaneous enoxaparin therapy and warfarin her symptoms of upper limb pain improved. She responded very well to medical therapy for heart failure with marked improvement of NYHA functional class. (author)

  11. Superior vena cava syndrome in hemodialysis patient

    Directory of Open Access Journals (Sweden)

    Azeb Molhem

    2011-01-01

    Full Text Available Obstruction of blood flow in the superior vena cava (SVC results in symptoms and signs of SVC syndrome. SVC obstruction can be caused either by invasion or external compression of the SVC by contagious pathologic processes involving the right lung, lymph nodes, and other mediastinal structures, or by thrombosis of blood within the SVC. Occasionally, both mechanisms co-exist. We hereby report a case of a 28-year-old male, Saudi patient who was diagnosed with end-stage renal disease and was maintained on regular hemodiaysis via right jugular vein dual lumen catheter for ten months. Three years later, the patient presented with signs and symptoms suggestive of SVC obstruction that was successfully managed with SVC stenting.

  12. The structural study of prefabrication stress stent and the hemodynamics in percutaneous transhepatic portacaval shunt

    International Nuclear Information System (INIS)

    Chu Jianguo; Sun Xiaoli; Zhou Yijun; Huang He; Zhou Hua; Lv Chunyan; Yang Shuhui

    2006-01-01

    Objective: To present a preliminary latest procedure for portal hypertension and evaluate the technical feasibility and efficacy of portacaval shunt creation through the percutaneous transhepatic approach in order to make a hemodynamic comparison with that of the classic TIPS. Methods: Thirty-eight patients with portal hypertension (36 men; mean age 57 years, range 32-73) were referred for PTPS procedure because of bleeding varices (n=36), intractable ascites (n=1), and hepatopulmonary syndrome (n=1). The severity of liver disease was classified as Child-Pugh B in 27 and C in 11. The PTPS was created by a percutaneous transhepatic puncture into right portal vein and then through left portal vein to the hepatic segment of IVC followed by a prefabrication stress stent-graft placement at the very site. Results: Technical and functional success of 100% was achieved in all patients, without related complications. The postprocedural portal vein-IVC gradients mean 13 cmH 2 O was achieved with the follow-up period mean 493 days. No recurrence of variceal bleeding and controlled refractory ascites were achieved, and still more with primary patency rate of the involved vascular structure up to 94.8% at 365 days, much better than classic TIPS. Conclusions: Portacaval shunt creation using the prefabrication stress stent via percutaneous transhepatic technique is safe and feasible. the compact coincidence was obtained between the stent and the involved vessel with restoration of intrahepatic portal venous hemodynamics together with partial lowering of portal venous pressure and guaranteeing intrahepatic perfusion through right portal vein. It is also obviously to have postoperative prevention of shunt restenoses and lowering postoperative incidence of hepato-encephalopathy. (authors)

  13. The value of percutaneous transhepatic treatment of biliary strictures following pediatric liver transplantation

    Directory of Open Access Journals (Sweden)

    Leandro Cardarelli-Leite

    Full Text Available Abstract Objective: To evaluate the percutaneous transhepatic approach to the treatment of biliary strictures in pediatric patients undergoing liver transplantation. Materials and Methods: This was a retrospective study of data obtained from the medical records, laboratory reports, and imaging examination reports of pediatric liver transplant recipients who underwent percutaneous transhepatic cholangiography, because of clinical suspicion of biliary strictures, between 1st September 2012 and 31 May 2015. Data were collected for 12 patients, 7 of whom were found to have biliary strictures. Results: In the 7 patients with biliary strictures, a total of 21 procedures were carried out: 2 patients (28.6% underwent the procedure twice; 3 (42.8% underwent the procedure three times; and 2 (28.6% underwent the procedure four times. Therefore, the mean number of procedures per patient was 3 (range, 2–4, and the average interval between them was 2.9 months (range, 0.8–9.1 months. The drainage tube remained in place for a mean of 5.8 months (range, 3.1–12.6 months. One patient presented with a major complication, hemobilia, which was treated with endovascular embolization. Clinical success was achieved in all 7 patients, and the mean follow-up after drain removal was 15.4 months (range, 5.3–26.7 months. Conclusion: The percutaneous transhepatic approach to treating biliary strictures in pediatric liver transplant recipients proved safe, with high rates of technical and clinical success, as well as a low rate of complications.

  14. Combined Surgical and Transhepatic Rendezvous Procedure for Relieving Anastomotic Biliary Obstruction in Children with Liver Transplants.

    Science.gov (United States)

    Crowley, John; Soltys, Kyle; Sindhi, Rakesh; Baskin, Kevin; Yilmaz, Sabri; Close, Orrie; Medsinge, Avinash

    2017-08-01

    Four children (3 boys and 1 girl, age 1.4-9.4 y) presented 2-70 months after liver transplantation (mean 26 months) with high-grade narrowing at the surgical anastomosis that could not be crossed at percutaneous transhepatic cholangiography. Each patient was treated with a combined surgical and interventional radiology "rendezvous" procedure. Biliary drainage catheters were left in place for an average of 6 months after the procedure. At a mean 7.5 months after biliary drainage catheter removal, all children were catheter-free without clinical or biochemical evidence of biliary stricture recurrence. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  15. Percutaneous transhepatic drainage of lung abscess through a diaphragmatic fistula caused by a penetrating liver abscess.

    Science.gov (United States)

    Taniguchi, Masako; Morita, Satoru; Ueno, Eiko; Hayashi, Mitsutoshi; Ishikawa, Motonao; Mae, Masahiro

    2011-11-01

    Liver abscesses occurring just below the diaphragm can penetrate or perforate the thoracic cavity, resulting in lung abscess or pyothorax. Although surgical or percutaneous transpleural drainage is often required in such cases, the latter approach has some risks, including hemothorax and bronchopleural fistula formation when the cavity is surrounded by normal lung parenchyma. The present report describes a treatment technique of percutaneous transhepatic drainage through the diaphragmatic fistula to avoid the risks of a transpulmonary approach in a case of lung abscess caused by a penetrating liver abscess.

  16. Mesenteric vein thrombosis after percitaneous transhepatic portal vein catheterisation for the localisation of an insulinoma

    International Nuclear Information System (INIS)

    Luska, G.; Langer, H.E.; Le Blanc, S.; Medizinische Hochschule Hannover

    1984-01-01

    The authors report on a fatal mesenteric vein thrombosis following an uncomplicated percutaneous transhepatic portal vein catheterisation for the localisation of an insulinoma. Several hours after the procedure the patient developed an acute abdomen. An emergency laparotomy revealed a haemorrhagic infarct of the ileum. The resected specimen showed an acute phlebitis with fresh thrombus. The cause of the phlebothrombosis was thought to be intimal damage from high osmolar contrast medium. There was no evidence of damage due to the catheder, either on the phlebogram or pathologically. (orig.) [de

  17. Recanalization of an Occluded Intrahepatic Portosystemic Covered Stent via the Percutaneous Transhepatic Approach

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Chih Yang; Liang, Po Chin [National Taiwan University Hospital, Taipei (China)

    2010-08-15

    A 41-year-old woman with liver cirrhosis had recurrent portal hypertension and bleeding from esophageal varices due to complete occlusion of a previously inserted transjugular intrahepatic portosystemic shunt stent. Because recanalization of the stent by the transjugular approach was unsuccessful, ultrasound-guided entry to the splenic vein and portal vein was used. After catheter-directed intrathrombus thrombolysis, successful opening of the stent was achieved and a stent was placed. We herein report a rare case in which thrombolysis and recanalization of a TIPS stent were performed via a percutaneous transhepatic approach

  18. Preoperative percutaneous transhepatic internal drainage in obstructive jaundice: a randomized, controlled trial examining renal function.

    Science.gov (United States)

    Smith, R C; Pooley, M; George, C R; Faithful, G R

    1985-06-01

    Thirty patients with obstructive jaundice with plasma bilirubin values greater than 200 mumol/L were randomized at the time of percutaneous transhepatic Cholangiography to undergo immediate or delayed surgery. The patients who had preoperative percutaneous transhepatic biliary drainage (PTBD) for 13.8 +/- 5.8 days had fewer surgical complications than did patients who underwent immediate surgery (p less than 0.02), although when the complications of PTBD were included this advantage was diminished. Immediate surgery caused greater deterioration of renal function as measured by plasma urea, plasma B 2-microglobulin, phosphate clearance, uric acid clearance, and maximal concentrating ability than occurred after PTBD or delayed surgery. The improvement in phosphate clearance that followed PTBD was sustained through delayed surgical treatment, indicating better tubular function in these patients. This article supports the concept that preoperative PTBD will reduce surgical morbidity and will result in less renal impairment than will immediate surgery. However, the morbidity rates of the PTBD procedure will preclude its wide use.

  19. TIPS Placement via Combined Transjugular and Transhepatic Approach for Cavernous Portal Vein Occlusion: Targeted Approach

    Directory of Open Access Journals (Sweden)

    Natanel Jourabchi

    2013-01-01

    Full Text Available Purpose. We report a novel technique which aided recanalization of an occluded portal vein for transjugular intrahepatic portosystemic shunt (TIPS creation in a patient with symptomatic portal vein thrombosis with cavernous transformation. Some have previously considered cavernous transformation a contraindication to TIPS. Case Presentation. 62-year-old man with chronic pancreatitis, portal vein thrombosis, portal hypertension and recurrent variceal bleeding presents with melena and hematemesis. The patient was severely anemic, hemodynamically unstable, and required emergent portal decompression. Attempts to recanalize the main portal vein using traditional transjugular access were unsuccessful. After percutaneous transhepatic right portal vein access and navigation of a wire through the occluded main portal vein, an angioplasty balloon was inflated at the desired site of shunt takeoff. The balloon was targeted and punctured from the transjugular approach, and a wire was passed into the portal system. TIPS placement then proceeded routinely. Conclusion. Although occlusion of the portal vein increases difficulty of performing TIPS, it should not be considered an absolute contraindication. We have described a method for recanalizing an occluded portal vein using a combined transhepatic and transjugular approach for TIPS. This approach may be useful to relieve portal hypertension in patients who fail endoscopic and/or surgical therapies.

  20. Complications of percutaneous transhepatic biliary drainage in patients with dilated and nondilated intrahepatic bile ducts

    International Nuclear Information System (INIS)

    Weber, Andreas; Gaa, Jochen; Rosca, Bogdan; Born, Peter; Neu, Bruno; Schmid, Roland M.; Prinz, Christian

    2009-01-01

    Percutaneous transhepatic biliary drainage (PTBD) have been described as an effective technique to obtain biliary access. Between January 1996 and December 2006, a total of 419 consecutive patients with endoscopically inaccessible bile ducts underwent PTBD. The current retrospective study evaluated success and complication rates of this invasive technique. PTBD was successful in 410/419 patients (97%). The success rate was equal in patients with dilated and nondilated bile ducts (p = 0.820). In 39/419 patients (9%) procedure related complications could be observed. Major complications occurred in 17/419 patients (4%). Patients with nondilated intrahepatic bile ducts had significantly higher complication rates compared to patients with dilated intrahepatic bile ducts (14.5% vs. 6.9%, respectively [p = 0.022]). Procedure related deaths were observed in 3 patients (0.7%). In conclusion, percutaneous transhepatic biliary drainage is an effective procedure in patients with dilated and nondilated intrahepatic bile ducts. However, patients with nondilated intrahepatic bile ducts showed a higher risk for procedure related complications.

  1. Incidence of Important Hemobilia Following Transhepatic Biliary Drainage: Left-Sided Versus Right-Sided Approaches

    International Nuclear Information System (INIS)

    Rivera-Sanfeliz, G. M.; Assar, O. S. A.; LaBerge, J. M.; Wilson, M. W.; Gordon, R. L.; Ring, E. J.; Kerlan, R. K. Jr.

    2004-01-01

    Our purpose here is to describe our experience with important hemobilia following PTBD and to determine whether left-sided percutaneous transhepatic biliary drainage (PTBD) is associated with an increased incidence of important hemobilia compared to right-sided drainages. We reviewed 346 transhepatic biliary drainages over a four-year period and identified eight patients (2.3%) with important hemobilia requiring transcatheter embolization. The charts and radiographic files of these patients were reviewed. The side of the PTBD (left versus right), and the order of the biliary ductal branch entered (first, second, or third) were recorded. Of the 346 PTBDs, 269 were right-sided and 77 were left-sided. Of the eight cases of important hemobilia requiring transcatheter embolization, four followed right-sided and four followed left-sided PTBD, corresponding to a bleeding incidence of 1.5% (4/269) for right PTBD and 5.2% (4/77) for left PTBD. The higher incidence of hemobilia associated with left-sided PTBD approached, but did not reach the threshold of statistical significance (p = 0.077). In six of the eight patients requiring transcatheter embolization, first or second order biliary branches were accessed by catheter for PTBD. All patients with left-sided bleeding had first or proximal second order branches accessed by biliary drainage catheters. In conclusion, a higher incidence of hemobilia followed left- versus right-sided PTBD in this study, but the increased incidence did not reach statistical significance

  2. Percutaneous transhepatic cholangiobiopsy to determine the pathological cause of anastomotic stenosis after cholangiojejunostomy for malignant obstructive jaundice

    International Nuclear Information System (INIS)

    Li, T.-F.; Ren, K.-W.; Han, X.-W.; Li, W.-C.; Ren, J.-L.; Jiao, D.-C.; Li, Z.; Ma, J.

    2014-01-01

    Aim: To investigate the feasibility and advantages of cholangiobiopsy during percutaneous transhepatic cholangiography in the histopathological diagnosis of anastomotic stenosis after cholangiojejunostomy for malignant obstructive jaundice. Materials and methods: Using biopsy forceps, specimens were collected from the site of stenosis in patients with recurrent jaundice (n = 24) who had previously undergone cholangiojejunostomy for malignant obstructive jaundice. Results: Stenosis occurred in all patients at the biliary–enteric anastomosis based on percutaneous transhepatic cholangiography, and was the location of the biopsy. Satisfactory specimens were obtained from 22 out of 24 patients. The sensitivity was 91.7% (22/24). Tumour tissue was obtained in 18 cases, confirming disease recurrence. Histopathological changes in four patients were diagnosed as fibroplasia and/or inflammation. These were considered cicatricial stenoses based on histopathological, imaging, and laboratory findings. The remaining two histopathology-negative patients were proven to have recurrent tumour based on imaging, laboratory, and follow-up data. No complications occurred during biopsy, including gastrointestinal haemorrhage or perforation. Either cholangial drainage and/or an inner stent was used following biopsy, which resulted in a noticeable decrease in jaundice postoperatively (p < 0.05). Conclusion: Percutaneous transhepatic cholangiobiopsy using biopsy forceps for the diagnosis of anastomotic stenosis after cholangiojejunostomy for malignant biliary obstructive jaundice is easy to perform and safe, with a high level of sensitivity. Interventional therapies, such as percutaneous transhepatic cholangial drainage and stent placement, can be performed concurrently, markedly improving the symptoms of patients with obstructive jaundice

  3. Retrieval of an intra-cardiac embolised very long wire via transhepatic access from a war victim child.

    Science.gov (United States)

    Baspinar, Osman; Sahin, Derya A; Yildirim, Ali

    2016-04-01

    We present the case report of a war victim child with severe burn scars, orthopnoea, and dyspnoea due to diffuse pulmonary thromboembolism. During ICU stay, a central venous catheter's 45-mm wire embolised into the heart. The embolised wire was successfully removed via transhepatic access through the creation of an artificial simple snare.

  4. Percutaneous transhepatic obliteration of stomal variceal hemorrhage from an ileal conduct: Case report and brief literature review

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seung Hyun; Lee, Shin Jae; Won, Jong Yun; Park, Sung Il; Lee, Do Yun; Kim, Man Deuk [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Do Young [Institute of Gastroenterology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-11-15

    Variceal bleeding is an unusual complication of ileal conduits. We report a case in which recurrent stomal variceal hemorrhage from an ileal conduit for bladder cancer was successfully treated by percutaneous transhepatic obliteration (PTO) using microcoils and N-butyl cyanoacrylate. Therefore, PTO can be one treatment option to prevent recurrent stomal variceal bleeding from ileal conduits.

  5. Tumor vessels and contrast enhancement of hepatocellular carcinoma demonstrated by percutaneous transhepatic portography. Report of a case

    Energy Technology Data Exchange (ETDEWEB)

    Fujisawa, I.; Minami, S.; Tsutsui, K.; Imura, T.; Asano, M.; Kitamura, O.; Matsumoto, M.; Ozawa, K.; Torizuka, K.

    A patient with an Edmondson type I-II hepatocellular carcinoma had, at celiac angiography, a poor arterial supply but a rich portal supply as observed at percutaneous transhepatic portography, an observation not previously reported in this disease. The importance of demonstrating the vascular supply of the tumor previous to planned intravascular treatment is obvious.

  6. [The safety and effect of transhepatic hilar approach for the treatment of bismuth type Ⅲ and Ⅳ hilar cholangiocarcinoma].

    Science.gov (United States)

    He, M; Wang, H L; Yan, J Y; Xu, S W; Chen, W; Wang, J

    2018-05-01

    Objective: To compare the efficiency between the transhepatic hilar approach and conventional approach for the surgical treatment of Bismuth type Ⅲ and Ⅳ hilar cholangiocarcinoma. Methods: There were 42 consecutive patients with hilar cholangiocarcinoma of Bismuth type Ⅲ and Ⅳ who underwent surgical treatment at Department of Biliary-Pancreatic Surgery, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University from January 2008 to December 2013.The transhepatic hilar approach was used in 19 patients and conventional approach was performed in 23 patients.There were no differences in clinical parameters between the two groups(all P >0.05). The t-test was used to analyze the measurement data, and the χ(2) test was used to analyze the count data.Kaplan-Meier analysis was used to analyze the survival period.Multivariate COX regression analysis was used to analyze the prognosis factors. Results: Among the 19 patients who underwent transhepatic hilar approach, 3 patients changed the operative planning after reevaluated by exposing the hepatic hilus.The intraoperative blood was 300(250-400)ml in the transhepatic hilar approach group, which was significantly less than the conventional approach group, 800(450-1 300)ml( t =4.276, P =0.00 1), meanwhile, the R0 resection rate was significantly higher in the transhepatic hilar approach group than in the conventional approach group(89.4% vs . 52.2; χ(2)=6.773, P =0.009) and the 3-year and 5-year cumulative survival rate was better in the transhepatic hilar approach group than in the conventional approach group(63.2% vs . 47.8%, 26.3% vs . 0; χ(2)=66.363, 127.185, P =0.000). On univariate analysis, transhepatic hilar approach, intraoperative blood loss, intraoperative blood transfusion, R0 resection and lymph node metastasis were significant risk factors for patient survival(all P hilar approach, intraoperative blood loss, R0 resection and lymph node metastasis were significant independent risk factors for

  7. Relato de caso: implante transparietohepático de cateter de longa permanência para diálise Case report: transhepatic insertion of long-term dialysis catheter

    Directory of Open Access Journals (Sweden)

    Felipe Nasser

    2007-12-01

    Full Text Available O implante transhepático de cateteres de diálise de longa permanência é um procedimento de exceção, utilizado para obter um acesso em pacientes com oclusão de veias centrais de membros superiores e inferiores. O caso descrito relata um paciente jovem, com história de 15 anos de diálise, que foi submetido no passado a um transplante renal sem sucesso. Esse paciente encontrava-se em urgência dialítica e oclusão comprovada de veias centrais de membros superiores e de veias ilíacas. Foi realizado o implante do cateter de longa permanência pelo acesso transparietohepático sob anestesia geral. A ponta do cateter foi posicionada ao nível do átrio direito. A diálise foi realizada satisfatoriamente no mesmo dia.Transhepatic insertion of long-term dialysis catheter is an exception procedure used to obtain access in patients with central vein occlusion of lower and upper limbs. We report on a case of a young patient with history of dialysis for 15 years, who was submitted to an unsuccessful renal transplantation. This patient was in dialytic emergency and had confirmed occlusion of upper limb central veins and iliac veins. Transhepatic insertion of a long-term catheter was performed under general anesthesia. The catheter tip was placed at the level of the right atrium. Dialysis was satisfactorily performed on the same day.

  8. Superior vena caval obstruction - decompression with chemotherapy and subsequent irradiation

    International Nuclear Information System (INIS)

    Kolaric, K.; Maricic, Z.; Dujmovic, I.; Mrsic, Z.

    1975-01-01

    The clinical picture, pathogenesis and etiology of malignant vena caval obstruction are described. The importance of using modern methods to treat this critical condition is emphasized. Furthermore, the authors examine the principles of chemotherapeutic decompression followed by irradiation. A single dose of nitrogen mustard was applied intravenously, followed by irradiation, on 24 patients with malignant vena caval obstruction. The results of this treatment are presented. The effect of this treatment was controlled by measuring the venous blood pressure and with chest X-rays. The authors conclude, that this method of decompression is successful in the palliative treatment of this syndrom. (orig.) [de

  9. The Optional VenaTech™ Convertible™ Vena Cava Filter: Experimental Study in Sheep

    International Nuclear Information System (INIS)

    Le Blanche, Alain F.; Ricco, Jean-Baptiste; Bonneau, Michel; Reynaud, Philippe

    2012-01-01

    Purpose: Retrieval of optional caval filters may be impaired by filter tilting, migration, fracture, or embedding in the IVC wall. The goal of this experimental study was to evaluate a new optional filter, convertible by unlocking and removing the filter head. Methods: Forty-nine Pre-Alp sheep (average weight, 55 kg) were anesthetized. IVC was catheterized via the right femoral vein (n = 46) or via the internal jugular vein (n = 3) with a 12.9-F sheath. VenaTech ™ Convertible ™ IVC filters were inserted as either permanent filters (n = 14) or as filters to be converted. Conversion was immediately after deployment (n = 19) or delayed after 1, 3, or 6 months (n = 20). Filter delivery, deployment, and conversion with measurement of migration and tilting were evaluated by cavography. Incorporation of the filter’s stabilizers and arms in the IVC wall was assessed by gross anatomy. Results: Delivery system insertion, filter release, and immediate conversion were successful in all cases. Delayed conversion was completed in all but one sheep, due to insufficient snare tension. Complimentary balloon-catheter inflation was required in 12 of 20 delayed conversions to achieve filter opening. In all 49 sheep, no thrombosis, migration, or significant tilting occurred. Within 4 weeks of conversion, the filter’s stabilizers and arms were incorporated into the IVC wall. Upon removal, the filter head was free of intimal growth. Conclusions: The VenaTech ™ Convertible ™ optional IVC filter was successfully implanted in all sheep with no migration or tilting. Conversion at various dates by filter head removal was feasible in all but one case.

  10. Diagnostic value of percutaneous transhepatic cholangiography judged by personal experience of 58 patients

    International Nuclear Information System (INIS)

    Nagasue, N.; Inokuchi, K.

    1979-01-01

    During the last seven years percutaneous transhepatic cholangiography (PTC) using a fine needle was performed in 58 patients. The biliary tract was visualised and opacified in the 52 patients with dilated biliary ducts. The correct diagnoses were made in 51 of them. In six patients with a non-dilated biliary system, successful PTC was carried out with the correct diagnoses in four of them. There were four non-fatal complications; two septic reactions, one haemobilia, and one subcapsular haematoma, but all were controlled by conservative treatment alone. The PTC with a fine needle is an accurate, useful and safe procedure of choice for the diagnosis of obstructive jaundice and jaundice of obscure origin. It is useful in distinguishing hepatocellular jaundice from obstructive jaundice thus preventing an unnecessary operation. Failure to visualise the biliary tract by an experienced hand strongly indicates that the jaundice is not-obstructive. (author)

  11. Hepatic Encephalopathy due to Congenital Multiple Intrahepatic Portosystemic Venous Shunts Successfully Treated by Percutaneous Transhepatic Obliteration

    Directory of Open Access Journals (Sweden)

    Shinsuke Takenaga

    2016-11-01

    Full Text Available Hepatic encephalopathy due to intrahepatic portosystemic venous shunts (IPSVS in a non-cirrhotic condition is rare. Here we report a rare case of a patient with congenital multiple IPSVS successfully treated by percutaneous transhepatic obliteration. The patient was a 67-year-old woman who presented to our hospital with progressive episodes of consciousness disorder and vomiting. Laboratory tests revealed hyperammonemia (192.0 μg/dL, and computed tomography revealed multiple IPSVS in both lobes. There was no evidence of underlying liver disease or hepatic trauma. Transcatheter embolization for IPSVS was performed because conservative therapy was not sufficiently effective. After endovascular shunt closure, hepatic encephalopathy improved. The serum ammonia level normalized during the 5-year follow-up period. Thus, transcatheter embolization may be an effective therapy for patients with symptomatic and refractory IPSVS. Careful follow-up is necessary for portal hypertension-related complications after transcatheter embolization for IPSVS.

  12. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    Energy Technology Data Exchange (ETDEWEB)

    Burcharth, F; Aagaard, J

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P < 0.025). All patients with varices had bled. Half of the patients in the group with hepatofugal blood flow had a false splenoportographic diagnosis of portal vein thrombosis. In conclusion, total hepatofugal postal blood flow exists more often than hitherto assumed. Hepatofugal blood flow does not relieve portal hypertension nor prevent development of gastro-oesophageal varices or bleeding.

  13. Percutaneous Trans-hepatic Obliteration for Bleeding Esophagojejunal Varices After Total Gastrectomy and Esophagojejunostomy

    International Nuclear Information System (INIS)

    Boku, Michiko; Sugimoto, Koji; Nakamura, Tetsu; Kita, Yasufumi; Zamora, Carlos A.; Sugimura, Kazuro

    2006-01-01

    A 72-year-old man who had undergone a total gastrectomy with a Roux-en-Y esophagojejunostomy for gastric cancer 6 years earlier presented to our hospital with massive hematemesis and melena. Endoscopic examination indicated esophageal varices with cherry-red spots and hemorrhage arising from beyond the anastomosis. Abdominal contrast-enhanced computed tomography and angiography revealed a dilated vein in the elevated jejunal limb supplying the varices. Percutaneous trans-hepatic obliteration (PTO) of the varices through the jejunal vein was performed using microcoils, ethanolamine oleate, and gelatin sponge cubes. Ten days after the procedure, endoscopic examination revealed reduction and thrombosis of the varices. We consider PTO to be an effective alternative method for treating ruptured esophagojejunal varices after total gastrectomy

  14. Percutaneous transhepatic techniques for management of biliary anastomotic strictures in living donor liver transplant recipients

    Directory of Open Access Journals (Sweden)

    Chinmay B Kulkarni

    2017-01-01

    Full Text Available Aim: To retrospectively analyze the percutaneous transhepatic techniques and their outcome in the management of biliary strictures in living donor liver transplant (LDLT recipients. Materials and Methods: We retrieved the hospital records of 400 LDLT recipients between 2007 and 2015 and identified 45 patients with biliary strictures. Among them, 17 patients (37.8% (Male: female = 13:4; mean age, 36.1 ± 17.5 years treated by various percutaneous transhepatic biliary techniques alone or in combination with endoscopic retrograde cholangiopancreatography (ERCP were included in the study. The technical and clinical success of the percutaneous management was analyzed. Results: Anastomotic strictures associated with leak were found in 12/17 patients (70.6%. Ten out of 12 (83.3% patients associated with leak had more than one duct-duct anastomoses (range, 2–3. The average duration of onset of stricture in patients with biliary leak was 3.97 ± 2.68 months and in patients with only strictures it was 14.03 ± 13.9 months. In 6 patients, endoscopic-guided plastic stents were placed using rendezvous technique, plastic stent was placed from a percutaneous approach in 1 patient, metallic stents were used in 2 patients, cholangioplasty was performed in 1 patient, N-butyl- 2-cyanoacrylate embolization was done in 1 child with biliary-pleural fistula, internal-external drain was placed in 1 patient, and only external drain was placed in 5 patients. Technical success was achieved in 12/17 (70.6% and clinical success was achieved in 13/17 (76.5% of the patients. Posttreatment mean time of follow-up was 19.4 ± 13.7 months. Five patients (29.4% died (two acute rejections, one metabolic acidosis, and two sepsis. Conclusions: Percutaneous biliary techniques are effective treatment options with good outcome in LDLT patients with biliary complications.

  15. Persistent high serum bilirubin level after percutaneous transhepatic biliary drainage: analysis of 32 cases

    International Nuclear Information System (INIS)

    Choo, In Wook; Choi, Byung Ihn; Park, Jae Hyung; Han, Man Chung; Kim, Chu Wan

    1986-01-01

    The aim of percutaneous transhepatic biliary drainage (PTBD) is to decrease serum bilirubin level and promote liver function in patient with biliary tract disease, especially obstruction by malignant disease. But some patients showed persistent high serum bilirubin level or higher than pre-PTBD level. Percutaneous transhepatic biliary drainage was performed in 341 patients of obstructive jaundice for 5 years form July, 1981 to July, 1986 at department of radiology, Seoul National University Hospital. Follow up check of the serum bilirubin level was possible in 188 patients. Among them the authors analysed 32 patients who showed persistent high serum bilirubin level after PTBD. The results were as follows: 1. The male to female ratio was 3.4:1 and the age ranged from 33 to 75. 2. The causes of obstructive jaundice included 30 malignant diseases and 2 benign diseases. Malignant disease were 16 cases of bile duct carcinoma, 7 cases of pancreatic cancer and 7 cases of metastasis from stomach, colon and uterine cervix. Benign disease were 1 case of common hepatic duct stone and 1 case of intrahepatic duct stones. 3. The most common level of obstruction was trifurcation in 17 cases. 4. The most common indication of PTBD was palliative drainage of obstruction secondary to malignant tumor in 28 cases. 5. Change of serum bilirubin level ratio (post-PTBD level/pre-PTBD level) was 1.28, 1.22, 1.38, 1.51 in serial period of 1-3 days, 4-6 days, 1-2 week 2-3 week after PTBD. 6. Causes of persistent high serum bilirubin level after PTBD were 12 cases of partial drainage of intrahepatic bile, 13 cases of hepatic dysfunction including 9 cases of metastatic nodule, 2 cases of biliary cirrhosis, 2 cases of multiple liver abscess, and 7 cases of poor function of catheter including 4 cases of hemobilia, 1 case of multiple intrahepatic stones, pyobilia and intrahepatic Clonorchis sinensis.

  16. Persistent high serum bilirubin level after percutaneous transhepatic biliary drainage: analysis of 32 cases

    Energy Technology Data Exchange (ETDEWEB)

    Choo, In Wook; Choi, Byung Ihn; Park, Jae Hyung; Han, Man Chung; Kim, Chu Wan [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1986-12-15

    The aim of percutaneous transhepatic biliary drainage (PTBD) is to decrease serum bilirubin level and promote liver function in patient with biliary tract disease, especially obstruction by malignant disease. But some patients showed persistent high serum bilirubin level or higher than pre-PTBD level. Percutaneous transhepatic biliary drainage was performed in 341 patients of obstructive jaundice for 5 years form July, 1981 to July, 1986 at department of radiology, Seoul National University Hospital. Follow up check of the serum bilirubin level was possible in 188 patients. Among them the authors analysed 32 patients who showed persistent high serum bilirubin level after PTBD. The results were as follows: 1. The male to female ratio was 3.4:1 and the age ranged from 33 to 75. 2. The causes of obstructive jaundice included 30 malignant diseases and 2 benign diseases. Malignant disease were 16 cases of bile duct carcinoma, 7 cases of pancreatic cancer and 7 cases of metastasis from stomach, colon and uterine cervix. Benign disease were 1 case of common hepatic duct stone and 1 case of intrahepatic duct stones. 3. The most common level of obstruction was trifurcation in 17 cases. 4. The most common indication of PTBD was palliative drainage of obstruction secondary to malignant tumor in 28 cases. 5. Change of serum bilirubin level ratio (post-PTBD level/pre-PTBD level) was 1.28, 1.22, 1.38, 1.51 in serial period of 1-3 days, 4-6 days, 1-2 week 2-3 week after PTBD. 6. Causes of persistent high serum bilirubin level after PTBD were 12 cases of partial drainage of intrahepatic bile, 13 cases of hepatic dysfunction including 9 cases of metastatic nodule, 2 cases of biliary cirrhosis, 2 cases of multiple liver abscess, and 7 cases of poor function of catheter including 4 cases of hemobilia, 1 case of multiple intrahepatic stones, pyobilia and intrahepatic Clonorchis sinensis.

  17. Risk factors for recurrent symptomatic pigmented biliary stones after percutaneous transhepatic biliary extraction.

    Science.gov (United States)

    Kim, Dong Won; Lee, Sang Yun; Cho, Jin-Han; Kang, Myong Jin; Noh, Myung Hwan; Park, Byeong-Ho

    2010-07-01

    To evaluate risk factors for the recurrence of biliary stones after a percutaneous transhepatic biliary stone extraction. The procedures were performed on 339 patients between July 2004 and December 2008 (54 months). Medical records and images were retrospectively reviewed for 135 patients (mean age, 66.4 years; 83 men and 52 women) who had undergone follow-up for a mean of 13.2 months (range, 3-37 months). To evaluate risk factors for the recurrence of biliary stones, variables were evaluated with univariate and multivariate analyses. Variables included sex, age, stone location, number of stones, stone size, presence of a peripapillary diverticulum, application of antegrade sphincteroplasty, presence of a biliary stricture, largest biliary diameter before the procedure, and gallbladder status. Thirty-three of the 135 patients (24%) had recurrent symptomatic biliary stones and underwent an additional extraction. The mean time to recurrence was 17.2 months +/- 8.7. Univariate analysis of risk factors for recurrence of biliary stones demonstrated that location, number of stones, stone size, application of antegrade sphincteroplasty, presence of a biliary stricture, and biliary diameter were significant factors (P or =6; relative risk, 64.8; 95% confidence interval: 5.8, 717.6) and stone size (> or =14 mm; relative risk, 3.8; 95% confidence interval: 1.138, 13.231) were determined to be significant risk factors. The independent risk factors for recurrence of symptomatic biliary stones after percutaneous transhepatic biliary stone extraction were a stone size of at least 14 mm and the presence of at least six stones. Copyright 2010 SIR. Published by Elsevier Inc. All rights reserved.

  18. Percutaneous Transhepatic Endoscopic Holmium Laser Lithotripsy for Intrahepatic and Choledochal Biliary Stones

    International Nuclear Information System (INIS)

    Rimon, Uri; Kleinmann, Nir; Bensaid, Paul; Golan, Gil; Garniek, Alexander; Khaitovich, Boris; Winkler, Harry

    2011-01-01

    Purpose: To report our approach for treating complicated biliary calculi by percutaneous transhepatic endoscopic biliary holmium laser lithotripsy (PTBL). Patients and Methods: Twenty-two symptomatic patients (11 men and 11 women, age range 51 to 88 years) with intrahepatic or common bile duct calculi underwent PTBL. Nine patients had undergone previous gastrectomy and small-bowel anastomosis, thus precluding endoscopic retrograde cholangiopancreatography. In the other 13 patients, stone removal attempts by ERCP failed due to failed access or very large calculi. We used a 7.5F flexible ureteroscope and a 200-μm holmium laser fiber by way of a percutaneous transhepatic tract, with graded fluoroscopy, to fragment the calculi with direct vision. Balloon dilatation was added when a stricture was seen. The procedure was performed with the patient under general anaesthesia. A biliary drainage tube was left at the end of the procedure. Results: All stones were completely fragmented and flushed into the small bowel under direct vision except for one patient in whom the procedure was aborted. In 18 patients, 1 session sufficed, and in 3 patients, 2 sessions were needed. In 7 patients, balloon dilatation was performed for benign stricture after Whipple operation (n = 3), for choledochalenteric anastomosis (n = 3), and for recurrent cholangitis (n = 1). Adjunctive “balloon push” (n = 4) and “rendezvous” (n = 1) procedures were needed to completely clean the biliary tree. None of these patients needed surgery. Conclusion: Complicated or large biliary calculi can be treated successfully using PTBL. We suggest that this approach should become the first choice of treatment before laparoscopic or open surgery is considered.

  19. Scimitar syndrome of atypical, rare drainage of venous vessel to the superior vena cava. A case report

    International Nuclear Information System (INIS)

    Sybilski, Adam J.; Michalczuk, Małgorzata; Chudoba, Anna; Tolak-Omernik, Katarzyna; Bulski, Tomasz; Walecki, Jerzy

    2013-01-01

    Scimitar syndrome is a rare and complex congenital anomaly characterized by partial or complete anomalous pulmonary venous return from the right or left lung into the inferior vena cava, through drainage into the hepatic vein, right atrium or left atrium. The syndrome is commonly associated with hypoplasia of the right lung and right pulmonary artery. We present an 11-year-old female with atypical and rare type of scimitar syndrome. The girl has had cough for 2 months before admission, without fever or abnormalities on medical examination. X-ray films revealed inflammatory and atelectatic changes with mediastinal shift to the right. CT and CT angiography – hypoplasia of the right lung with no visible interlobar fissures. No areas of consolidation in the pulmonary parenchyma. Mediastinum shifted to the right. Single wide venous vessels draining the upper part of the right lung entering the superior vena cava. In our patient, clinical symptoms are mild, but a thorough physical examination could have helped diagnose the syndrome earlier

  20. Vena porta thrombosis in patient with inherited factor VII deficiency

    DEFF Research Database (Denmark)

    Klovaite, Jolanta; Friis-Hansen, Lennart Jan; Larsen, Fin S

    2010-01-01

    with inherited FVII deficiency and chronic vena porta thrombosis. She presented at 32 weeks of gestation with spontaneously increased international normalized ratio, severe thrombocytopenia and very few unspecific symptoms. The extensive examination of the patient revealed cavernous transformation of the portal...

  1. Superior vena cava obstruction caused by radiation induced venous fibrosis

    NARCIS (Netherlands)

    Van Putten, JWG; Schlosser, NJJ; Vujaskovic, Z; Van der Leest, AHD; Groen, HJM

    Superior vena cava syndrome is most often caused by lung carcinoma. Two cases are described in whom venous obstruction in the superior mediastinum was caused by local vascular fibrosis due to radiotherapy five and seven years earlier. The development of radiation injury to greater vessels is

  2. An urban trauma centre experience with abdominal vena cava injuries

    African Journals Online (AJOL)

    Background: The aim of the study was to present the surgical management of injuries to the abdominal vena cava (AVC) and to identify clinical and physiological factors and management strategies which affect the outcome. Methods: A retrospective review was conducted of AVC injuries in patients attending the trauma ...

  3. Percutaneous insertion of inferior vean cava filter:clinical results of 8 patients

    International Nuclear Information System (INIS)

    Bae, Kyung Soo; Shin, Hyun Woong; Park, No Hyuck; Ryeom, Hun Kyu; Kim, Yong Joo

    1997-01-01

    To evaluate the efficacy and clinical results of percutaneous insertion of inferior vena cava(IVC) filter. Over a two year period, eight IVC filters were placed in eight patients with pulmonary thromboembolism resulting from deep vein thrombosis of the legs. The indications for placement were contraindication to anticoagulation(3), and recurrent pulmonary embolism during anticoagulant therapy(5). Both femoral(7) and jugular(1) routes were used for percutaneous transvenous insertion. To delineate the caval anatomy and to ensure placement just caudal to the renal vein, a cavogram was obtained before filter placement. Bird's Nest (7) and Greenfield (1) filters were inserted. Follow-up information was obtained by means of duplex sonography, CT scan, abdominal radiograph, and perfusion scan of the lungs, followed by clinical evaluation. In all cases, procedures were technically successful. Placement complications occurred in three patients. In one, the filter was inadvertently placed above the iliac bifurcation; in the other two, prolapse of the Bird's Nest filter wire occurred. Occlusion of IVC occurred in two patients, and recurrent pulmonary embolism was suspected in one, who suffered from chest pain and short-ness of breath. In the other patients, there was no clinical evidence of recurrence of the pulmonary embolism. Insertion of an inferior vena cava filter is a safe and effective method for the prevention of pulmonary embolism when anticoagulant therapy is either ineffective or contraindicated

  4. Three-dimensional magnetic resonance imaging overlay to assist with percutaneous transhepatic access at the time of cardiac catheterization

    Directory of Open Access Journals (Sweden)

    Wendy Whiteside

    2015-01-01

    Full Text Available Multimodality image overlay is increasingly used for complex interventional procedures in the cardiac catheterization lab. We report a case in which three-dimensional magnetic resonance imaging (3D MRI overlay onto live fluoroscopic imaging was utilized to safely obtain transhepatic access in a 12-year-old patient with prune belly syndrome, complex and distorted abdominal anatomy, and a vascular mass within the liver.

  5. Three-dimensional magnetic resonance imaging overlay to assist with percutaneous transhepatic access at the time of cardiac catheterization

    International Nuclear Information System (INIS)

    Whiteside, Wendy; Christensen, Jason; Zampi, Jeffrey D

    2005-01-01

    Multimodality image overlay is increasingly used for complex interventional procedures in the cardiac catheterization lab. We report a case in which three-dimensional magnetic resonance imaging (3D MRI) overlay onto live fluoroscopic imaging was utilized to safely obtain transhepatic access in a 12-year-old patient with prune belly syndrome, complex and distorted abdominal anatomy, and a vascular mass within the liver

  6. Percutaneous transhepatic biliary stenting in patients with intradiverticular papillae and biliary strictures caused by ampullary carcinoma: A case report

    OpenAIRE

    NIU, HONG-TAO; HUANG, QIANG; ZHAI, REN-YOU

    2014-01-01

    Endoscopic retrograde cholangiopancreatography with endoscopic sphincterotomy is a well-established procedure for the treatment of bile duct strictures. However, the procedure is difficult to perform in patients with intradiverticular papillae or tumor infiltration of the major papilla. Percutaneous transhepatic biliary stenting (PTBS) is commonly used in the management of malignant biliary stricture. The current study reports two cases of PTBS performed to treat malignant obstructive jaundic...

  7. Focused transhepatic electroporation mediated by hypersaline infusion through the portal vein in rat model. Preliminary results on differential conductivity

    Directory of Open Access Journals (Sweden)

    Pañella Clara

    2017-11-01

    Full Text Available Spread hepatic tumours are not suitable for treatment either by surgery or conventional ablation methods. The aim of this study was to evaluate feasibility and safety of selectively increasing the healthy hepatic conductivity by the hypersaline infusion (HI through the portal vein. We hypothesize this will allow simultaneous safe treatment of all nodules by irreversible electroporation (IRE when applied in a transhepatic fashion.

  8. Safety and efficacy of transhepatic and transsplenic access for endovascular management of portal vein complications after liver transplantation.

    Science.gov (United States)

    Ohm, Joon-Young; Ko, Gi-Young; Sung, Kyu-Bo; Gwon, Dong-Il; Ko, Heung Kyu

    2017-09-01

    The purpose of this article is to evaluate and compare the safety and efficacy of endovascular management of the portal vein (PV) via percutaneous transsplenic access versus percutaneous transhepatic access in liver transplantation (LT) recipients. A total of 18 patients who underwent endovascular management of PV via percutaneous transhepatic (n = 8) and transsplenic (n = 10) access were enrolled. Transsplenic access was chosen if the spleen was located in a normal position, the splenic vein (SpV) was preserved, and the target lesion did not involve confluence of the superior mesenteric and SpVs. Accessibility of the percutaneous transsplenic puncture was confirmed via ultrasound (US) in the angiography suite. All procedures were performed under local anesthesia. Percutaneous transhepatic or transsplenic access was performed using a 21-gauge Chiba needle under US and fluoroscopic guidance, followed by balloon angioplasty, stent placement, or variceal embolization. The access tract was embolized using coils and a mixture (1:2) of glue and ethiodized oil. Transhepatic or transsplenic access was successfully achieved in all patients. A total of 12 patients underwent stent placement; 3 had balloon angioplasty only; 2 had variceal embolization only; and 1 had variceal embolization followed by successful stent placement. Regarding major complications, 1 patient experienced a SpV tear with extravasation during transsplenic balloon angioplasty, which was successfully managed using temporary balloon inflation, followed by transfusion. Clinical success was achieved in 9 of 11 (82%) patients who exhibited clinical manifestations. The remaining 7 patients who underwent prophylactic endovascular management were healthy. In conclusion, endovascular management of PV via percutaneous transsplenic access is a relatively safe and effective alternative that does not damage the liver grafts of LT recipients. Liver Transplantation 23 1133-1142 2017 AASLD. © 2017 by the American

  9. Percutaneous transhepatic stent placement in the management of portal venous stenosis after curative surgery for pancreatic and biliary neoplasms.

    Science.gov (United States)

    Kim, Kyung Rae; Ko, Gi-Young; Sung, Kyu-Bo; Yoon, Hyun-Ki

    2011-04-01

    The purpose of this study was to evaluate the efficacy and safety of stent placement in the management of portal venous stenosis after curative surgery for pancreatic and biliary neoplasms. From September 1995 to April 2007, percutaneous transhepatic portal venous stent placement was attempted in 19 patients with postoperative portal venous stenosis. Portal venous stenosis was a complication of surgery in 11 patients and caused by tumor recurrence in eight patients. The clinical manifestations were ascites, hematochezia, melena, esophageal varices, and abnormal liver function. Stents were placed in the stenotic or occluded lesions after percutaneous transhepatic portography. Technical and clinical success, stent patency, and complications were evaluated. Stent placement was successful in 18 patients (technical success rate, 95%). Clinical manifestations improved in 16 patients (clinical success rate, 84%). The mean patency period among the 18 patients with technical success was 21.3 ± 23.2 months. The mean patency period of the benign stenosis group (30.1 ± 25.6 months) was longer than that of the tumor recurrence group (7.3 ± 7.7 months), and the difference was statistically significant (p = 0.038). There were two cases of a minor complication (transient fever) and three cases of major complications (septicemia, liver abscess, and acute portal venous thrombosis). Percutaneous transhepatic stent placement can be safe and effective in relieving portal venous stenosis after curative surgery for pancreatic and biliary neoplasms. Patients with benign stenosis had more favorable results than did those with tumor recurrence.

  10. Percutaneous Transhepatic Drainage of Inaccessible Abdominal Abscesses Following Abdominal Surgery Under Real-Time CT-Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Yamakado, Koichiro; Takaki, Haruyuki; Nakatsuka, Atsuhiro; Kashima, Masataka; Uraki, Junji; Yamanaka, Takashi; Takeda, Kan

    2010-01-01

    This study evaluated the safety, feasibility, and clinical utility of transhepatic drainage of inaccessible abdominal abscesses retrospectively under real-time computed tomographic (CT) guidance. For abdominal abscesses, 12 consecutive patients received percutaneous transhepatic drainage. Abscesses were considered inaccessible using the usual access route because they were surrounded by the liver and other organs. The maximum diameters of abscesses were 4.6-9.5 cm (mean, 6.7 ± 1.4 cm). An 8-Fr catheter was advanced into the abscess cavity through the liver parenchyma using real-time CT fluoroscopic guidance. Safety, feasibility, procedure time, and clinical utility were evaluated. Drainage catheters were placed with no complications in abscess cavities through the liver parenchyma in all patients. The mean procedure time was 18.8 ± 9.2 min (range, 12-41 min). All abscesses were drained. They shrank immediately after catheter placement. In conclusions, this transhepatic approach under real-time CT fluoroscopic guidance is a safe, feasible, and useful technique for use of drainage of inaccessible abdominal abscesses.

  11. Vena Cava Filter Retrieval with Aorto-Iliac Arterial Strut Penetration.

    Science.gov (United States)

    Holly, Brian P; Gaba, Ron C; Lessne, Mark L; Lewandowski, Robert J; Ryu, Robert K; Desai, Kush R; Sing, Ronald F

    2018-05-03

    To evaluate the safety and technical success of inferior vena cava (IVC) filter retrieval in the setting of aorto-iliac arterial strut penetration. IVC filter registries from six large United States IVC filter retrieval practices were retrospectively reviewed to identify patients who underwent IVC filter retrieval in the setting of filter strut penetration into the adjacent aorta or iliac artery. Patient demographics, implant duration, indication for placement, IVC filter type, retrieval technique and technical success, adverse events, and post procedural clinical outcomes were identified. Arterial penetration was determined based on pre-procedure CT imaging in all cases. The IVC filter retrieval technique used was at the discretion of the operating physician. Seventeen patients from six US centers who underwent retrieval of an IVC filter with at least one strut penetrating either the aorta or iliac artery were identified. Retrieval technical success rate was 100% (17/17), without any major adverse events. Post-retrieval follow-up ranging from 10 days to 2 years (mean 4.6 months) was available in 12/17 (71%) patients; no delayed adverse events were encountered. Findings from this series suggest that chronically indwelling IVC filters with aorto-iliac arterial strut penetration may be safely retrieved.

  12. A new Nitinol stent for use in superior vena cava syndrome

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Midtgaard, Annette; Brenøe, Anne-Sofie

    2015-01-01

    AIM: The aim of the study was to assess the early clinical experience with the Zilver Vena stent in treating patients with malignant superior vena cava syndrome. METHODS: Demographic, procedural, and follow-up data of 12 patients (seven women; mean age 69 years) treated for superior vena cava...... syndrome with in all 21 Zilver Vena stents between March 2012 and October 2013 were retrospectively reviewed. All cavographies and contrast enhanced CT related to the treatment and during follow-up were evaluated and the patients had clinical follow-up until dead. They were all in terminal state...... at the time of stent deployment. RESULTS: All patients had superior vena cava obstruction and clinical superior vena cava syndrome caused by malignant expansive mediastinal disease (eight patients non-small cell lung cancer and four small cell lung cancer). The technical success with deployment of the stents...

  13. Partial anomalous pulmonary venous connection to the superior vena cava.

    Science.gov (United States)

    Aramendi, José I; Rey, Estibaliz; Hamzeh, Gadah; Crespo, Alejandro; Luis, Maite; Voces, Roberto

    2011-04-01

    We describe the surgical technique of reimplantation of the right superior pulmonary vein into the left atrium in 2 patients with partial anomalous pulmonary venous connection to the superior vena cava without atrial septal defect. A right axillary minithoracotomy is done through the fourth intercostal space. The pulmonary vein is detached from its origin in the superior vena cava. This is sutured with 6-0 reabsorbable polydioxanone suture (Ethicon, Somerville, NJ). A lateral clamp is applied to the left atrium, and the pulmonary vein is reimplanted. The patient is extubated in the operating room. Neither cardiopulmonary bypass nor blood transfusion was required. It is simple, safe, and reproducible. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Myofibroblastic tumor associated to superior vena cava syndrome

    International Nuclear Information System (INIS)

    Ortega Jaramillo, Hector; Durango Gutierrez, Luisa Fernanda; Perez Figueroa, Maria del Pilar

    2005-01-01

    Inflammatory myofibroblastic tumor (IMT) is an uncommon pathological entity of unknown cause, composed of differentiated myofibroblastic cells accompanied by plasma cells, lymphocytes and eosinophils, which involve extrapulmonary and pulmonary tissues. IMT has an unpredictable clinical course, rarely undergoes malignant transformation. Local invasion and involvement of the mediastinum and hiliar structures are unusual manifestations; however; we reports a case of superior vena cava syndrome and IMT

  15. Aneurisma de la vena de Galeno Galen's vein aneurysm

    Directory of Open Access Journals (Sweden)

    Sergio Piloña Ruiz

    2010-09-01

    Full Text Available La malformación arteriovenosa de la vena de Galeno es una enfermedad congénita poco frecuente que se produce a partir de un defecto en la fusión de las venas cerebrales internas y que, debido a la baja resistencia, produce un cuadro de falla cardíaca de alto gasto. Las manifestaciones clínicas son muy variables y dependen de la edad de presentación. El pronóstico depende del tamaño del aneurisma. Se presenta el caso de un recién nacido del sexo masculino, con diagnóstico prenatal de aneurisma de la vena de Galeno y, desde el nacimiento, graves signos de insuficiencia cardíaca congestiva de difícil tratamiento. Se realiza una revisión sobre el tema.Arteriovenous malformation of Galen's vein is an uncommon congenital disease present from a defect in internal cerebral veins fusion and that due to the low resistance, produces a high output heart failure. Clinical manifestations are very variables depending on age of presentation. Prognosis depends on the size of aneurysm. This is the case of a male newborn diagnosed prenatally with Galen's vein aneurysm and from his birth severe signs of congestive heart failure of difficult treatment. A literature review on this subject is made.

  16. Usefulness of a Biliary Manipulation Catheter in Percutaneous Transhepatic Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Paek, Auh Whan [Dept. of Radiology, Virginia University Heath Center, Charlottesville (United States); Won, Je Hwan; Lee, Jei Hee; Sun, Joo Sung; Kwak, Kyu Sung; Bae, Jae Ik [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2011-04-15

    To evaluate usefulness of a manipulation catheter in percutaneous transhepatic biliary drainage (PTBD). A biliary manipulation catheter was used for the aspiration of retained bile and lesion crossing during an initial PTBD in 91 consecutive patients over a 6 month period. This catheter allowed for a 0.035 inch guide wire made of 5F short steel braided polyurethane. The terminal 1 cm segment was tapered and 45 degree angulated. Two side holes were made in the terminal segment to facilitate the aspiration of bile. The safety of this procedure was evaluated based on whether the catheters caused complications during insertion and manipulation, and whether cholangitis was aggravated after the procedure. Effectiveness of the procedure was evaluated based on the ability to aspirate retained bile and to cross the lesion. Both the insertion of a 0.035 inch hydrophilic guide wire and aspiration of sufficient retained bile were successful with the catheter. Crossing the common bile duct (CBD) lesion had a 98.1% success rate during the initial PTBD. Crossing the hilar obstruction lesion was had a 94.7% success rate to the CBD and 92.1% to the contralateral lobe. Cholangitis improved in 97% of cases, and aggravated transiently in only 3% of cases after PTBD.

  17. Treatment of biliary stricture by percutaneous transhepatic insertion of metallic stent

    International Nuclear Information System (INIS)

    He Xiaofeng; Shan Hong; Chen Yong; Li Yanhao

    1997-01-01

    Purpose: Percutaneous transhepatic insertion of biliary stent (PTIBS) was adopted for treating malignant and benign biliary stricture. The therapeutic effect, technique and complications were investigated. Materials and methods: Twenty-five patients with biliary stricture were treated by PTIBS, including hilar biliary cancer 16 cases, pancreatic cancer 4 cases, hilar metastatic cancer 3 cases, and post-operative biliary stricture of bile duct 2 cases. Results: The technical success rate was 96.0% (24/25). Two stents were placed in the right and left hepatic ducts respectively in 2 cases. The survival rate of 6 and 12 months were 73.3% and 46.6%. Restenosis rate was 40.0% in 6 months. Mild hemobilia (44.0%) and retrograde infection (8.0%) were the main complications which could be managed by conservative treatment. Conclusion: It was suggested that PTIBS was a safe and effective method in the treatment of biliary stricture. There was higher success rate of PTIBS as compared to endoscopic retrograde biliary, approach especially in patients with hilar biliary stricture. If combined with chemotherapy, the survival rate of malignant biliary stricture could be further improved

  18. Usefulness of a Biliary Manipulation Catheter in Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    Paek, Auh Whan; Won, Je Hwan; Lee, Jei Hee; Sun, Joo Sung; Kwak, Kyu Sung; Bae, Jae Ik

    2011-01-01

    To evaluate usefulness of a manipulation catheter in percutaneous transhepatic biliary drainage (PTBD). A biliary manipulation catheter was used for the aspiration of retained bile and lesion crossing during an initial PTBD in 91 consecutive patients over a 6 month period. This catheter allowed for a 0.035 inch guide wire made of 5F short steel braided polyurethane. The terminal 1 cm segment was tapered and 45 degree angulated. Two side holes were made in the terminal segment to facilitate the aspiration of bile. The safety of this procedure was evaluated based on whether the catheters caused complications during insertion and manipulation, and whether cholangitis was aggravated after the procedure. Effectiveness of the procedure was evaluated based on the ability to aspirate retained bile and to cross the lesion. Both the insertion of a 0.035 inch hydrophilic guide wire and aspiration of sufficient retained bile were successful with the catheter. Crossing the common bile duct (CBD) lesion had a 98.1% success rate during the initial PTBD. Crossing the hilar obstruction lesion was had a 94.7% success rate to the CBD and 92.1% to the contralateral lobe. Cholangitis improved in 97% of cases, and aggravated transiently in only 3% of cases after PTBD.

  19. Percutaneous transhepatic biliary stenting vs. surgical bypass in advanced malignant biliary obstruction: cost- effectiveness analysis.

    Science.gov (United States)

    Yao, Li Qin; Tang, Cheng Wu; Zheng, Yin Yuan; Feng, Wen Ming; Huang, San Xiong; Bao, Ying

    2013-01-01

    This study aims to compare the clinical outcomes and costs between percutaneous transhepatic biliary stenting (PTBS) and surgical bypass. We randomly assigned 142 patients with unresectable malignant biliary obstruction between 2005 and 2010 to receive PTBS or surgical bypass as palliative treatment. PTBS was successfully performed in 70 patients who formed the PTBS group (failed in 7 patients). Sixty five patients underwent surgical bypass treatment. Additional gastrojejunostomy was performed in five patients. The effectiveness of biliary drainage, hospital stay, complications, cost, survival time and mortality were compared. Patients in PTBS group had shorter hospital stay and lower initial and overall expense than the surgical group (pPTBS group was significantly lower than surgical group (3/75 vs. 11/65, p=0.0342). Late complication in PTBS group did not differ significantly from surgical group (9/70 vs. 6/65, p=0.6823). The survival curves in the two groups showed no significant difference (p=0.1032). PTBD is a better palliative treatment than surgical bypass for unresectable malignant biliary obstruction for its high effectiveness of biliary drainage and acceptable expense and complication.

  20. A prototype percutaneous transhepatic cholangiography training simulator with real-time breathing motion.

    Science.gov (United States)

    Villard, P F; Vidal, F P; Hunt, C; Bello, F; John, N W; Johnson, S; Gould, D A

    2009-11-01

    We present here a simulator for interventional radiology focusing on percutaneous transhepatic cholangiography (PTC). This procedure consists of inserting a needle into the biliary tree using fluoroscopy for guidance. The requirements of the simulator have been driven by a task analysis. The three main components have been identified: the respiration, the real-time X-ray display (fluoroscopy) and the haptic rendering (sense of touch). The framework for modelling the respiratory motion is based on kinematics laws and on the Chainmail algorithm. The fluoroscopic simulation is performed on the graphic card and makes use of the Beer-Lambert law to compute the X-ray attenuation. Finally, the haptic rendering is integrated to the virtual environment and takes into account the soft-tissue reaction force feedback and maintenance of the initial direction of the needle during the insertion. Five training scenarios have been created using patient-specific data. Each of these provides the user with variable breathing behaviour, fluoroscopic display tuneable to any device parameters and needle force feedback. A detailed task analysis has been used to design and build the PTC simulator described in this paper. The simulator includes real-time respiratory motion with two independent parameters (rib kinematics and diaphragm action), on-line fluoroscopy implemented on the Graphics Processing Unit and haptic feedback to feel the soft-tissue behaviour of the organs during the needle insertion.

  1. Cytological Sampling Versus Forceps Biopsy During Percutaneous Transhepatic Biliary Drainage and Analysis of Factors Predicting Success

    Energy Technology Data Exchange (ETDEWEB)

    Tapping, C. R.; Byass, O. R.; Cast, J. E. I., E-mail: james.cast@hey.nhs.uk [Hull Royal Infirmary, Department of Radiology (United Kingdom)

    2012-08-15

    Purpose: To assess the accuracy of cytological sampling and forceps biopsy in obstructing biliary lesions and to identify factors predictive of success. Methods: Consecutive patients (n = 119) with suspected malignant inoperable obstructive jaundice treated with percutaneous transhepatic biliary drainage during 7 years were included (60 male; mean age 72.5 years). All patients underwent forceps biopsy plus cytological sampling by washing the forceps device in cytological solution. Patient history, procedural and pathological records, and clinical follow-up were reviewed. Statistical analysis included chi-square test and multivariate regression analysis. Results: Histological diagnosis after forceps biopsy was more successful than cytology: Sensitivity was 78 versus 61%, and negative predictive value was 30 versus 19%. Cytology results were never positive when the forceps biopsy was negative. The cytological sample was negative and forceps sample positive in 2 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 1 case of benign disease. Diagnostic accuracy was predicted by low bilirubin (p < 0.001), aspartate transaminase (p < 0.05), and white cell count (p {<=} 0.05). Conclusions: This technique is safe and effective and is recommended for histological diagnosis during PTBD in patients with inoperable malignant biliary strictures. Diagnostic yield is greater when bilirubin levels are low and there is no sepsis; histological diagnosis by way of forceps biopsy renders cytological sampling unnecessary.

  2. The Usefulness of Virtual Fluoroscopic Preprocedural Planning During Percutaneous Transhepatic Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Mitsuhiro, E-mail: kinoshita.3216@tokushima-u.ac.jp [Tokushima University Hospital, Department of Radiology (Diagnostic Radiology) (Japan); Shirono, Ryozo; Takechi, Katsuya [Tokushima Red Cross Hospital, Department of Radiology (Japan); Yonekura, Hironobu [Tokushima Red Cross Hospital, Department of Radiological Technology (Japan); Iwamoto, Seiji [Tokushima University Graduate School, Department of Radiology and Radiation Oncology, Institute of Biomedical Sciences (Japan); Shinya, Takayoshi [Tokushima University Hospital, Department of Radiology (Diagnostic Radiology) (Japan); Takao, Shoichiro [Tokushima University Graduate School of Health Science, Department of Diagnostic Radiology (Japan); Harada, Masafumi [Tokushima University Graduate School, Department of Radiology and Radiation Oncology, Institute of Biomedical Sciences (Japan)

    2017-06-15

    Purpose To retrospectively evaluate the usefulness of virtual fluoroscopic preprocedural planning (VFPP) in the percutaneous transhepatic biliary drainage (PTBD) procedure.Materials and MethodsTwenty-two patients who were treated by PTBD were included in this study. Twelve patients were treated using PTBD intraoperative referencing coronal computed tomography (CT) images (i.e., coronal CT group), and ten patients were treated using PTBD intraoperative referencing VFPP images (i.e., VFPP group). To analyze the effect of the intraoperative referencing VFPP image, the VFPP group was retrospectively compared with the coronal CT group.ResultsThe characteristics of both patient groups were not statistically significantly different. There were no significant differences in the targeted bile duct, diameter and depth of the target bile, breath-holding ability, number of targeted bile duct puncture attempts, change in the targeted bile duct, and exchange of the drainage catheter. However, the X-ray fluoroscopy time and the procedure time were significantly shorter in the VFPP group than in the coronal CT group (196 vs. 334 s, P < 0.05; and 16.0 vs. 27.2 min, P < 0.05).ConclusionIntraoperative referencing using the VFPP imaging in PTBD intuitively can be a useful tool for better localization of the guidewire in the bile duct and thereby shorten the X-ray fluoroscopy time and procedure time while minimizing radiation exposure and complications.

  3. Percutaneous transhepatic biliary drainage(PTBD): comparative data of right and left hepatic lobe approach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyeong; Yoon, Yup [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-08-15

    To evaluate the difference in each procedure time and complication rates related to percutaneous transhepatic biliary drainage(PTBD) via the right and the left hepatic lobe. We performed PTBD in 120 patients with biliary obstruction below both main hepatic ducts. Of the 120 catheters, 54 were introduced via a left lobe approach and 66 through the right lobe. All procedures were performed under fluoroscopic guidance by the same operator. For each patient, procedure time was recorded prospectively. PTBD related complications were classified as either early(up to 30 days after procedure) or late(after 30 days), and each complication graded as major, or minor according to its intensity. The difference in the mean procedure time(28.8 min, versus 36.2 min, left versus right approach group) and that in complication rates (37% versus 58%) were statistically significant({rho} < 0.05). Concerning major complication(bile peritonitis, sepsis, massive hemobilia, liver abscess, pyothorax), the percentages related to left and right lobe approach were 1.8% and 10.6%, and concerning minor complications(catheter obstruction or dislodgement, transient hemobilia, persistent fever or pain), the percentages were 36% and 51% respectively. PTBD via the left lobe approach was superior with short procedure time and low complication rates than the right approach.

  4. Therapeutic effects of percutaneous transhepatic variceal embolization combined with partial splenic embolization for portal hypertention

    International Nuclear Information System (INIS)

    Hua Yingxue; Yan Zhiping; Cheng Yongde; Qiao Delin; Zhou Bing; Chen Shiwei; Li Yong

    2007-01-01

    Objective: To evaluate the efficiency of percutaneous transhepatic variceal embolization (PTVE) combined with patial splenic embolization (PES)for portal hypertension. Methods: 30 patients with critical portal hypertension were divided randomly into two groups, 15 patients of A group underwent PSE PTVE combined with PSE and 15 of B group underwent PES only. The changes of collateral circulation of the two groups were compared via color Doppler ultrasonography pre-and postoperatively. Results: The hypersplenism was well controlled in both groups after PTVE and PSE. The varices of A group were embolized completely, the flow rate and velocity of portal blood stream were significantly reduced (P<0.05). In addition, the flow rate and velocity together with inner diameter of the azygous vein decreased (P<0.01), but no change shown on portal vein diameter, only with decrease of blood flow and velocity postoperatively were shown in the two groups (P<0.05). During 13-16 months follow-up, gastroesophageal variceal bleeding appeared in 2 patients and formation of portal thrombi in 1 patients of B group. There was no gastroesophageal variceal bleeding in A group but 2 patients appeared portal hypertensive gastroenteropathy (PHG)under endoscopic confirmations. Conclusion: PTVE combined PSE is very efficient for gastroesophageal variceal bleeding and hypersplenism due to portal hypertension, especially for patients with poor hepatic function, possessing simple, economic, less invasive properties and deserving to be recommended. (authors)

  5. The preparation of biodegradable vena filter and the study of its properties

    International Nuclear Information System (INIS)

    Zhang Xiao; Xiao Yueyong; Yang Jie; Ma Xuyang; Liu Shirong; Ren Chao; Wang Xiaoping

    2012-01-01

    Objective: To investigate the preparation of biodegradable vena cava filter (BVCF) with poly-l-lactic acid (PLLA), and to evaluate its mechanical properties, delivery performance, the ability of capturing thrombus and the degradation property. Methods: Three-dimensional design software was used to design the shape of BVCF. The BVCF was prepared by using PLLA with molecular weight of 100 000 unit. Twelve minipigs were used to test the feasibility of this BVCF. They were randomly divided into four groups. At first the BVCFs were placed into the inferior vena cava of pigs in three experimental groups. The fourth group was used as a blank control group. The thrombi were injected into all pigs after 1 week, and CT examinations were performed at different time points to observe the filter locations and pulmonary artery. The animals were sacrificed according to a fixed time table for histopathological assessment. Results: The BVCF was successfully designed and produced, which could expand by stretching the center-thread. In vitro test results showed the radial force of BVCF was approximately 1.6 N and could capture the thrombus more than 5 mm in diameter, and it was easy to release. Through the animal experiment confirmed that the filter could capture the lethal thrombus and all 9 pigs of experimental groups were survived, two of those had the symptoms of respiratory frequency and heartbeat accelerated slightly in the operation. In control group, the symptoms such as accelerate of respiratory rate, shortness of breath were observed in varying degree. The pig which was injected with 8 strips of thrombus died in the same day after surgery. Postoperative CT and pathological examinations showed that 2 pigs in the experimental group developed peripheral pulmonary embolism, while the dead pig in the control group developed central pulmonary embolism. Histological findings showed that the intima covered the BVCF lateral branch partly after one week,and thoroughly after six weeks

  6. Radiodiagnostic methods in determining the structure of tumor thrombus in the inferior vena cava in kidney cancer

    Directory of Open Access Journals (Sweden)

    N. B. Vikhrova

    2015-01-01

    Full Text Available Renal cell carcinoma (RCC is the most common primary tumor of the renal parenchyma. Venous involvement is one of the most important anatomic characteristics of tumor. It is known that venous spread influences the survival of patients with RCC. Tumor thrombosis of IVC in patients with renal cell carcinoma has been reported in 4–10 %. The reference standard for RCC with tumor thrombus remains surgical resection. The structure of thrombus determines some technical difficulties in the management of tumor. Spongeous thrombus correlate with higher risk of thrombus detachment during surgery resulting in PE. Therefore determination of IVC thrombus consistency is very important part of preoperative radiologic assessment of tumor in patients with RCC.

  7. Surgical resection of a renal cell carcinoma involving the inferior vena cava: the role of the cardiothoracic surgeon

    LENUS (Irish Health Repository)

    Parissis, Haralabos

    2010-11-05

    Abstract Background The techniques for the resection of renal tumors with IVC extension are based on the experience of individual units. We attempt to provide a logical approach of the surgical strategies in a stepwise fashion. Methods Over 6-years 9 patients with renal cell carcinoma invading the IVC, underwent surgery. There were 6 males. The extension was at level IV in 4 and III in 5 cases. CPB used in 8 and hypothermia and circulatory arrest in all patients with level IV disease. The results and an algorithm of the plan of action, as per level of extension are presented. Results Plan of action: For level I-II disease: No Cardiothoracic involvement, For level III: Cardiopulmonary Bypass (CPB) & control of the cavo-atrial junction. For level IV: use of brief periods of Circulatory Arrest & repair of the Cavotomy with a pericardial patch. Postoperative morbidity: prolonged ICU stay, 3 patients (33.3%); tracheostomy, 1 (11.1%); Sepsis, 2 (22.2%); CVA 1, (11.1%). Mortality: 2 patients (22.2%) Conclusions Total clearance of the IVC from an adherent tumor is important, therefore extensive level IV disease presents a surgical challenge. We recommend CPB for level III and brief periods of Total Circulatory Arrest (TCA) for level IV disease.

  8. Direct intrahepatic portocaval shunt creation via the inter-strut space of the inferior vena cava stent

    International Nuclear Information System (INIS)

    Tsauo, J.; Yu, Y.; Luo, X.; Wang, Z.; Liu, L.; Li, X.

    2014-01-01

    Highlights: • The feasibility of DIPS creation through an IVC stent was investigated. • DIPS creation through the IVC stent was successful in all four patients. • DIPS creation through the IVC stent is feasible

  9. Accuracy of Inferior Vena Cava Ultrasound for Predicting Dehydration in Children with Acute Diarrhea in Resource-Limited Settings.

    Science.gov (United States)

    Modi, Payal; Glavis-Bloom, Justin; Nasrin, Sabiha; Guy, Allysia; Chowa, Erika P; Dvor, Nathan; Dworkis, Daniel A; Oh, Michael; Silvestri, David M; Strasberg, Stephen; Rege, Soham; Noble, Vicki E; Alam, Nur H; Levine, Adam C

    2016-01-01

    Although dehydration from diarrhea is a leading cause of morbidity and mortality in children under five, existing methods of assessing dehydration status in children have limited accuracy. To assess the accuracy of point-of-care ultrasound measurement of the aorta-to-IVC ratio as a predictor of dehydration in children. A prospective cohort study of children under five years with acute diarrhea was conducted in the rehydration unit of the International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b). Ultrasound measurements of aorta-to-IVC ratio and dehydrated weight were obtained on patient arrival. Percent weight change was monitored during rehydration to classify children as having "some dehydration" with weight change 3-9% or "severe dehydration" with weight change > 9%. Logistic regression analysis and Receiver-Operator Characteristic (ROC) curves were used to evaluate the accuracy of aorta-to-IVC ratio as a predictor of dehydration severity. 850 children were enrolled, of which 771 were included in the final analysis. Aorta to IVC ratio was a significant predictor of the percent dehydration in children with acute diarrhea, with each 1-point increase in the aorta to IVC ratio predicting a 1.1% increase in the percent dehydration of the child. However, the area under the ROC curve (0.60), sensitivity (67%), and specificity (49%), for predicting severe dehydration were all poor. Point-of-care ultrasound of the aorta-to-IVC ratio was statistically associated with volume status, but was not accurate enough to be used as an independent screening tool for dehydration in children under five years presenting with acute diarrhea in a resource-limited setting.

  10. Surgical Treatment of Renal Cell Carcinoma with Inferior Vena Cava Thrombus: Using Liver Mobilization Technique to Avoid Cardiopulmonary Bypass

    Directory of Open Access Journals (Sweden)

    Tawatchai Taweemonkongsap

    2008-04-01

    CONCLUSION: These results support the aggressive surgical removal of RCC with IVC thrombus as the initial treatment. Most of the thrombi can be approached and safely controlled by a transabdominal approach without any form of bypass. Tumour thrombus removal provides a high survival chance and offers improvement in quality of life.

  11. Comparison of retrievable stents and permanent stents for Budd-Chiari syndrome due to obstructive inferior vena cava.

    Science.gov (United States)

    Bi, Yonghua; Chen, Hongmei; Ding, Penxu; Ren, Jianzhuang; Han, Xinwei

    2018-05-30

    To compare long-term outcomes of retrievable stents and permanent stents for BCS due to long-segment obstructive IVC. Between July 2000 and August 2016, 42 patients with BCS due to long-segment obstructive IVC were treated with retrievable stents (RS) and 41 patients were treated with permanent stents (PS). The retrievable stents was removed eventually after thrombus disappeared. Patients were subsequently followed-up by color Doppler sonography or CT scanning. All retrievable stent placements were successfully, and 37 retrievable stents were retrieved 8 to 29 days later. Forty-two stents were implanted in PS Group. One failure retrieval of retrievable stents occurred, and two failures of cannulations were found in PS Group. Two deaths may procedure-related and died from acute pulmonary thromboembolism perioperatively. One patient developed acute cerebral infarction and recovered after treatment. In PS Group, minor complications were found in 3 patients. The length of IVC lesion segment, length and thickness of IVC thrombus decreased significantly, and diameter of retrocaval IVC and diaphragm IVC increased significantly in both groups. During follow up, 3 patients died from liver failure in RS Group and 2 patients died in PS Group. RS Group showed a significantly higher primary patency rate than PS Group. Cumulative 1-, 3-, and 5-year secondary patency rates were 95.2%, 89.6%, 89.6% in RS Group, and 100%, 96.6%, 96.6% in PS Group (p= 0.7109). Retrievable stents is effective for BCS due to long-segment obstructive IVC, with a higher primary patency rate. This article is protected by copyright. All rights reserved.

  12. Accuracy of Inferior Vena Cava Ultrasound for Predicting Dehydration in Children with Acute Diarrhea in Resource-Limited Settings.

    Directory of Open Access Journals (Sweden)

    Payal Modi

    Full Text Available Although dehydration from diarrhea is a leading cause of morbidity and mortality in children under five, existing methods of assessing dehydration status in children have limited accuracy.To assess the accuracy of point-of-care ultrasound measurement of the aorta-to-IVC ratio as a predictor of dehydration in children.A prospective cohort study of children under five years with acute diarrhea was conducted in the rehydration unit of the International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b. Ultrasound measurements of aorta-to-IVC ratio and dehydrated weight were obtained on patient arrival. Percent weight change was monitored during rehydration to classify children as having "some dehydration" with weight change 3-9% or "severe dehydration" with weight change > 9%. Logistic regression analysis and Receiver-Operator Characteristic (ROC curves were used to evaluate the accuracy of aorta-to-IVC ratio as a predictor of dehydration severity.850 children were enrolled, of which 771 were included in the final analysis. Aorta to IVC ratio was a significant predictor of the percent dehydration in children with acute diarrhea, with each 1-point increase in the aorta to IVC ratio predicting a 1.1% increase in the percent dehydration of the child. However, the area under the ROC curve (0.60, sensitivity (67%, and specificity (49%, for predicting severe dehydration were all poor.Point-of-care ultrasound of the aorta-to-IVC ratio was statistically associated with volume status, but was not accurate enough to be used as an independent screening tool for dehydration in children under five years presenting with acute diarrhea in a resource-limited setting.

  13. 159. Trombectomía de Vena Cava Inferior Por Invasión de Tumor Renal

    Directory of Open Access Journals (Sweden)

    N. Miranda

    2012-04-01

    Conclusiones: en casos seleccionados, el carcinoma de célula renal extendiéndose a VCI puede ser resecado sin dificultad sin necesidad de esternotomía, CBP o PCHP, constituyendo una alternativa curativa en el tratamiento de dichos tumores.

  14. Bedside intravascular ultrasound-guided inferior vena cava filter placement in medical-surgical intensive care critically-ill patients

    Directory of Open Access Journals (Sweden)

    Mohammad A. Abusedera

    2015-09-01

    Conclusions: Bedside IVUS-guided filter placement in medical-surgical critically ill patient in intensive care unit is a feasible, safe and reliable technique for IVC interruption. IVUS may be the most appropriate tool to guide filter insertion in obese patient.

  15. Introducer curving technique for the prevention of tilting of transfemoral Günther Tulip inferior vena cava filter.

    Science.gov (United States)

    Xiao, Liang; Huang, De-sheng; Shen, Jing; Tong, Jia-jie

    2012-01-01

    To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters. The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval. The overall average ACF was 5.8 ± 4.14 degrees. In Group C, the average ACF was 7.1 ± 4.52 degrees. In Group T, the average ACF was 4.4 ± 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 ± 4.59 vs. 5.1 ± 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF ≥ 10°) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, χ(2) = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, χ(2) = 5.030, p = 0.025). The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting.

  16. Pusher curving technique for preventing tilt of femoral Geunther Tulip inferior vena cava filter: in vitro study

    International Nuclear Information System (INIS)

    Xiao Liang; Shen Jing; Huang Desheng; Xu Ke

    2011-01-01

    Objective: To determine whether the adjustment of the pusher of GTF was useful to decrease the degree of tilting of the femoral Geunther Tulip filter (GTF) in an in vitro caval model. Methods: The caval model was constructed by placement of a 25 mm × 100 mm and two 10 mm × 200 mm Dacron graft inside a transparent bifurcate glass tube. The study consisted of two groups: left straight group (GLS) (n = 100) and left curved group (G LC ) (n=100). In the G LC , a 10° to 20° angle was curved on the introducer. The distance (D CH ) between the caval right wall and the hook was measured. The degree of tilting (DT) was classified into 5 grades and recorded. Before and after the GTF being released, the angle (A CM1,2 ) between the axis of IVC and the metal mount, the distance (D CM1 ) between the caval right wall and the metal mount, the angle (ACF) between the axis of IVC and the axis of the filter and the diameter of IVC (D IVC ) were measured. The data were analyzed with Chi-Square test, t test, rank sum. test and Pearson correlation test. Results: The degree of GTF tilting in each group revealed a divergent tendency. In group LC , the apex of the filter tended to be grade Ⅲ compared in group LS (χ 2 value 37.491, P LS and G LC were considered as statistical significance (16.60° vs. 3.05°, 20.60° vs. 3.50°, -3.90° vs. -0.40°, 2.98 mm vs. 10.40 mm, -10.95° vs. -0.485°, 13.17 mm vs. 10.06 mm, -1.70° vs. 0.70°, t or Z values -12.187, -12.188, -8.545, -51.834, -11.395, 9.562, -3.596, P CM1 and A CF , A CM1 - A CM2 and D CH1 - D CH2 in each group, respectively (r values 0.978, 0.344, 0.879, 0.627, P CH1 and A CF in each group, A CP and A CF in group LC (r values -0.974, -0.322, -0.702, P CM1 and A CF , A CM1 - A CM2 and D CH1 - D CH2 in each group, respectively (r values 0.978, 0.344, 0.879, 0.627, P CH1 and A CF in each group, A CP and A CF in group LC (r values -0.974, -0.322, -0.702, P<0.01). Conclusion: The technique of adjusting the orientation of filter pusher had minimized the incidence and extent of GTF filter tilting in vitro. (authors)

  17. Bilateral catheter-directed thrombolysis in a patient with deep venous thrombosis caused by a hypoplastic inferior vena cava

    NARCIS (Netherlands)

    Sloot, S.; Van Nierop, J.; Kootstra, J. J.; Wittens, C.; Fritschy, W. M.

    Introduction Deep venous thrombosis treatment using catheter-directed thrombolysis is advocated over systemic thrombolysis because it reduces bleeding complications. With the development of a catheter that combines ultrasound vibrations and the local delivering of thrombolytics, new and safer

  18. Leiomyosarcoma of the inferior turbinate

    Directory of Open Access Journals (Sweden)

    Christopher W. Harper, Jr., MD

    2017-09-01

    Full Text Available We report a case of leiomyosarcoma of the inferior nasal turbinate. The patient, a 68-year-old Caucasian male, presented with 4–6 weeks of epistaxis that was resistant to nasal packing and septal cautery. Upon inspection in the operating room, a small mass was excised from the inferior turbinate. High-power H&E-stained microscopy demonstrated bundles of malignant smooth muscle cells, and immunohistochemical stains were strongly positive for desmin, smooth muscle actin and vimentin, while negative for pankeratin EA1/EA3 and CaM 5.2, suggesting leiomyosarcoma as the diagnosis. Clear margins were obtained at a second surgery. At the time of this writing it is 8 months since his last surgery and he has remained symptom free.

  19. Percutaneous Transhepatic Duodenal Drainage as an Alternative Approach in Afferent Loop Obstruction with Secondary Obstructive Jaundice in Recurrent Gastric Cancer

    International Nuclear Information System (INIS)

    Yao, N.-S.; Wu, C.-W.; Tiu, Chui-Mei; Liu, Jacqueline M.; Whang-Peng, Jacqueline; Chen, L.-T.

    1998-01-01

    Two cases are reported of chronic, partial afferent loop obstruction with resultant obstructive jaundice in recurrent gastric cancer. The diagnosis was made by characteristic clinical presentations, abdominal computed tomography, and cholescintigraphy. Percutaneous transhepatic duodenal drainage (PTDD) provided effective palliation for both afferent loop obstruction and biliary stasis. We conclude that cholescintigraphy is of value in making the diagnosis of partial afferent loop obstruction and in differentiating the cause of obstructive jaundice in such patients, and PTDD provides palliation for those patients in whom surgical intervention is not feasible

  20. Percutaneous transhepatic biliary stenting in patients with intradiverticular papillae and biliary strictures caused by ampullary carcinoma: A case report.

    Science.gov (United States)

    Niu, Hong-Tao; Huang, Qiang; Zhai, Ren-You

    2014-04-01

    Endoscopic retrograde cholangiopancreatography with endoscopic sphincterotomy is a well-established procedure for the treatment of bile duct strictures. However, the procedure is difficult to perform in patients with intradiverticular papillae or tumor infiltration of the major papilla. Percutaneous transhepatic biliary stenting (PTBS) is commonly used in the management of malignant biliary stricture. The current study reports two cases of PTBS performed to treat malignant obstructive jaundice caused by ampullary carcinoma complicated with intradiverticular papillae. PTBS is potentially a safe technique for this relatively rare condition.

  1. Widening of mediastinum with persistent left superior Vena cava - CT diagnosis

    International Nuclear Information System (INIS)

    Neuwirth, J.; Kolar, J.

    1992-01-01

    Described in this paper are radiographic findings recorded from a case of persistent left superior vena cava which grew manifest by widening of the left contour of the upper mediastinal region. Contrast-enhanced computed tomography (CT) was undertaken to clear up suspicion of mediastinal tumour and revealed double superior vena cava. The diagnosis was then confirmed by digital subtraction venography. (orig.) [de

  2. Cine computed tomography for diagnosis of superior vena cava obstruction following the mustard operation

    International Nuclear Information System (INIS)

    Matherne, G.P.; Atkins, D.L.; Frey, E.E.; Smith, W.L.

    1987-01-01

    Superior vena caval obstruction is a well described complication following Mustard's repair for transposition of the great arteries. We report a case of a 6-year-old child with superior vena cava obstruction correctly diagnosed by Cine-CT. The advantages of imaging with Cine-CT for this complication are discussed. (orig.)

  3. A DUPLICATED GREAT SAPHENOUS VEIN AND CLINICAL SIGNIFICANCE FOR VARICOSITY. Duplicación de la vena safena magna y significado clínico de las várices

    Directory of Open Access Journals (Sweden)

    Waseem Al Talalwah

    2016-03-01

    Full Text Available En varios estudios se ha relacionado la vena safena magna doble con dilataciones varicosas. Durante una clase de disección de pre-grado de la extremidad inferior se encontró una doble vena safena magna unilateral en el miembro inferior izquierdo de un cadáver masculino. La incidencia de esta variación fue del 1,3% de todos los especímenes muestra. En este trabajo se reporta la variabilidad del drenaje venoso de las extremidades inferiores para mejorar la conciencia para los radiólogos vasculares y proporcionar además una opción adicional en la cirugía de bypass de la arteria coronaria para evitar las várices iatrogénicas. A double great saphenous vein has been associated with varicosity in a number of studies. During routine undergraduate dissection of the lower limb a unilateral double great saphenous was found in the left lower limb of a male cadaver. The incidence of this variation was 1.3% of all specimens. This paper reports the variability of lower limb venous drainage to increase the awareness for vascular radiologists and provide further an additional option in coronary artery bypass surgery to avoid iatrogenic varicosity.

  4. Comparison of transhepatic and extrahepatic routes for EUS-guided rendezvous procedure for distal CBD obstruction.

    Science.gov (United States)

    Dhir, Vinay; Bhandari, Suryaprakash; Bapat, Mukta; Joshi, Nitin; Vivekanandarajah, Suhirdan; Maydeo, Amit

    2013-04-01

    EUS-guided rendezvous procedure (EUS-RV) can be done by the transhepatic (TH) or the extrahepatic (EH) route. There is no data on the preferred access route when both routes are available. To compare the success, complications, and duration of hospitalization for patients undergoing EUS-RV by the TH or the EH route. Patients with distal common bile duct (CBD) obstruction, who failed selective cannulation, underwent EUS-RV by the TH route through the stomach or the EH route through the duodenum. A total of 35 patients were analysed (17 TH, 18 EH). The mean procedure time was significantly longer for the TH group (34.4 vs. 25.7 min; p = 0.0004). There was no difference in the technical success (94.1 vs. 100%). However, the TH group had a higher incidence of post-procedure pain (44.1 vs. 5.5%; p = 0.017), bile leak (11.7 vs. 0; p = 0.228), and air under diaphragm (11.7 vs. 0; p = 0.228). All bile leaks were small and managed conservatively. Duration of hospitalization was significantly higher for the TH group (2.52 vs. 0.17 days; p = 0.015). EUS-RV has similar success rate by the TH or the EH route. However, the TH route has higher post-procedure pain, longer procedure time, and longer duration of hospitalization. The EH route should be preferred for EUS-RV in patients with distal CBD obstruction when both access routes are technically feasible.

  5. Obstructive Jaundice in Hepatocellular Carcinoma: Response after Percutaneous Transhepatic Biliary Drainage and Prognostic Factors

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Han, Joon Koo; Kim, Tae Kyoung; Choi, Byung Ihn; Park, Seong Ho; Ko, Young Hwan; Yoon, Chang Jin; Yeon, Kyung-Mo

    2002-01-01

    Purpose: To evaluate the therapeutic effect of percutaneous transhepatic biliary drainage (PTBD) in patients with obstructive jaundice caused by biliary involvement of hepatocellular carcinomas (HCC) and to determine the prognostic factors. Methods: We retrospectively analyzed the data of 22 consecutive patients (M:F = 20:2, mean age 52.8 years).Inclusion criteria were the patient having obstructive jaundice caused by HCC that invaded the bile ducts and having at least 4 weeks of follow-up data after the PTBD. We defined 'good response' and 'poor response' as whether the level of total bilirubin decreased more than 50% in 4 weeks or not. Total bilirubin level (T-bil),Child-Pugh score and the location of biliary obstruction for the two groups were compared. In addition, the interval between clinical onset of jaundice and PTBD, the degree of parenchymal atrophy and the size of the primary tumor were compared. Results: Of the 22 patients, 13 (59.1%) showed good response. T-bil was significantly lower in the good response group than in the poor (14.2 ± 6 mg/dlvs 25.9 ± 13.8 mg/dl, p = .017). In the five patients with T-bil 20 mg/dl, only three (33%)showed good response. Although statistically not significant, patients with Child score <10 showed better results [good response rate of 66.7% (12/18)] than patients with Child score ?10 [good response rate of 25% (1/4)]. Involvement of secondary confluence of the bile duct also served as a poor prognostic factor (p =0.235). The interval between clinical onset of jaundice and PTBD, the presence of parenchymal atrophy and the size of the tumor did not show significant effect. Conclusion: Early and effective biliary drainage might be necessary in this group of patients with limited hepatic function

  6. Diurnal variation in the biliary excretion of flomoxef in patients with percutaneous transhepatic biliary drainage.

    Science.gov (United States)

    Hishikawa, S; Kobayashi, E; Sugimoto , K; Miyata, M; Fujimura, A

    2001-07-01

    To examine diurnal variation in biliary excretion of flomoxef. Flomoxef (1 g) was injected intravenously in eight patients with percutaneous transhepatic cholangiography with drainage at 09.00 h and 21.00 h by a cross-over design with a 36 h washout period. Drained biliary fluid was collected for 6 h after each dosing. These patients still had mild to moderate hepatic dysfunction. Bile flow and bile acid excretion for 6 h after dosing did not differ significantly between the 09.00 h and 21.00 h treatments. The maximum concentration of biliary flomoxef was significantly greater and its total excretion for 6 h tended to be greater after the 21.00 h dose [maximum concentration (microg ml(-1)): 34.2 +/- 29.9 (09.00 h dose) vs 43.5 +/- 28.3 (21.00 h dose) (95% confidence interval for difference: 2.6 approximately 15.9, P = 0.013); total excretion (mg 6 h(-1)): 1.4 +/- 1.3 (09.00 h dose) vs 1.6 +/- 1.2 (21.00 h dose) (95% confidence interval for difference: -26.8, 313.7, P = 0.087)]. The period that biliary flomoxef remained above the minimal inhibitory concentration did not differ significantly between the two treatment times. These results suggest that biliary excretion of flomoxef shows diurnal variation. However, as the difference was relatively small, flomoxef could be given at any time of day without any dosage adjustments.

  7. Paravertebral Block: An Improved Method of Pain Control in Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    Culp, William C.; McCowan, Timothy C.; DeValdenebro, Miguel; Wright, Lonnie B.; Workman, James L.; Culp, William C.

    2006-01-01

    Background and Purpose. Percutaneous transhepatic biliary drainage remains a painful procedure in many cases despite the routine use of large amounts of intravenous sedation. We present a feasibility study of thoracic paravertebral blocks in an effort to reduce pain during and following the procedure and reduce requirements for intravenous sedation. Methods. Ten consecutive patients undergoing biliary drainage procedures received fluoroscopically guided paravertebral blocks and then had supplemental intravenous sedation as required to maintain patient comfort. Levels T8-T9 and T9-T10 on the right were targeted with 10-20 ml of 0.5% bupivacaine. Sedation requirements and pain levels were recorded. Results. Ten biliary drainage procedures in 8 patients were performed for malignancy in 8 cases and for stones in 2. The mean midazolam use was 1.13 mg IV, and the mean fentanyl requirement was 60.0 μg IV in the block patients. Two episodes of hypotension, which responded promptly to volume replacement, may have been related to the block. No serious complications were encountered. The mean pain score when traversing the chest wall, liver capsule, and upon entering the bile ducts was 0.1 on a scale of 0 to 10, with 1 patient reporting a pain level of 1 and 9 reporting 0. The mean peak pain score, encountered when manipulating at the common bile duct level or when addressing stones there, was 5.4 and ranged from 0 to 10. Conclusions. Thoracic paravertebral block with intravenous sedation supplementation appears to be a feasible method of pain control during biliary interventions

  8. Soft-Tissue-Anchored Transcutaneous Port for Long-Term Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    Nyman, Rickard; Ekloef, Hampus; Eriksson, Lars-Gunnar; Karlsson, Britt-Marie; Rasmussen, Ib; Lundgren, Dan; Thomsen, Peter

    2005-01-01

    Purpose. A transcutaneous port (T-port) has been developed allowing easy exchange of a catheter, which was fixed inside the device, using the Seldinger technique. The objective of the study was to test the T-port in patients who had percutaneous transhepatic biliary drainage (PTBD). Methods. The T-port, made of titanium, was implanted using local anesthesia in 11 patients (mean age 65 years, range 52-85 years) with biliary duct obstruction (7 malignant and 4 benign strictures). The subcutaneous part of the T-port consisted of a flange with several perforations allowing ingrowth of connective tissue. The T-port allowed catheter sizes of 10 and 12 Fr. Results. All wounds healed uneventfully and were followed by a stable period without signs of pronounced inflammation or infection. It was easy to open the port and to exchange the drainage tube. The patient's quality of life was considerably improved even though several patients had problems with repeated bile leakage due to frequent recurrent obstructions of the tubes. The ports were implanted for a mean time of 9 months (range 2-21 months). Histologic examination in four cases showed that the port was well integrated into the soft tissue. Tilting of the T-port in two cases led to perforation of the skin by the subcutaneous part of the ports, which were removed after 7 and 8 months. Conclusion. The T-port served as an excellent external access to the biliary ducts. The drainage tubes were well fixed within the ports. The quality of life of the patients was considerably improved. Together with improved aesthetic appearance they found it easier to conduct normal daily activities and personal care. However, the problem of recurrent catheter obstruction remained unsolved

  9. Estimate of X-radiation to patients during transhepatic artery chemoembolization for heptocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Shengli, Chen; Dongliang, Zhu; Guodong, Chen; Qihao, Huang; Zicheng, Huang; Qi, Xie; Rong' ai, Mu [The First Municipal People' s Hospital of Guangzhou, Guangzhou (China). Dept. of Radiology; Rongzhu, Zou

    2004-10-01

    Objective: To evaluate the X- radiation to patients of hepatocarcinoma during transhepatic artery chemoembolization (THACE). Methods: The radiation dose was measured in 82 patients (group A) during THACE for hepatocarcinoma. Measurements were carried out using a dosimeter system(Diamentor K1 and Diamentor ED) equipped in DSA setting Angiostar-Plus(Siemens, Germany), dose-area product (DAP) and entrance surface dose (ESD) were recorded on-line, and the effect dose (ED) was estimated by Monte-Carlo conversion coefficient from DAP. The effects of elevated tube voltage, reduced pulsed fluoroscopy (PF) frequency and curtailed total photography frames on radiation to the patients were studied by comparison with another 10 THACE cases treated recently (group B). Results: In group A, the mean fluoroscopic time was (35.3 {+-} 21.1) minutes, and the mean number of angiographic exposure was (234 {+-} 108) frames, the mean DAP dose was (21 748 {+-} 12 424) cGy/cm{sup 2}, and the mean ESD was (964 {+-} 632)mGy, ED was (34.8 {+-} 19.9)mSv. The contribution of pulsed fluoroscopy (PF) dose to the total DAP(24.0 {+-} 12.7)% was smaller than photography(R) (75.9 {+-} 10.7)%, and of PF to total ESD(49.8 {+-} 14.9)% was similar to R (51.7 {+-} 14.2)%. The total dose, fluoroscopy dose per minute and photography dose per frame in group B was reduced obviously than in group A. Conclusion: The HCC patients suffered a large dose of X-ray exposure in THACE procedure. The radiation exposure of patients can be reduced by elevating tube voltage, reducing pulsed fluoroscopy frequency and curtailing total photography frames moderately. (author)

  10. Estimate of X-radiation to patients during transhepatic artery chemoembolization for heptocarcinoma

    International Nuclear Information System (INIS)

    Chen Shengli; Zhu Dongliang; Chen Guodong; Huang Qihao; Huang Zicheng; Xie Qi; Mu Rong'ai; Zou Rongzhu

    2004-01-01

    Objective: To evaluate the X- radiation to patients of hepatocarcinoma during transhepatic artery chemoembolization (THACE). Methods: The radiation dose was measured in 82 patients (group A) during THACE for hepatocarcinoma. Measurements were carried out using a dosimeter system(Diamentor K1 and Diamentor ED) equipped in DSA setting Angiostar-Plus(Siemens, Germany), dose-area product (DAP) and entrance surface dose (ESD) were recorded on-line, and the effect dose (ED) was estimated by Monte-Carlo conversion coefficient from DAP. The effects of elevated tube voltage, reduced pulsed fluoroscopy (PF) frequency and curtailed total photography frames on radiation to the patients were studied by comparison with another 10 THACE cases treated recently (group B). Results: In group A, the mean fluoroscopic time was (35.3 ± 21.1) minutes, and the mean number of angiographic exposure was (234 ± 108) frames, the mean DAP dose was (21 748 ± 12 424) cGy/cm 2 , and the mean ESD was (964 ± 632)mGy, ED was (34.8 ± 19.9)mSv. The contribution of pulsed fluoroscopy (PF) dose to the total DAP(24.0 ± 12.7)% was smaller than photography(R) (75.9 ± 10.7)%, and of PF to total ESD(49.8 ± 14.9)% was similar to R (51.7 ± 14.2)%. The total dose, fluoroscopy dose per minute and photography dose per frame in group B was reduced obviously than in group A. Conclusion: The HCC patients suffered a large dose of X-ray exposure in THACE procedure. The radiation exposure of patients can be reduced by elevating tube voltage, reducing pulsed fluoroscopy frequency and curtailing total photography frames moderately. (author)

  11. Origin of a common trunk for the inferior phrenic arteries from the right renal artery: a new anatomic vascular variant with clinical implications.

    Science.gov (United States)

    Topaz, On; Topaz, Allyne; Polkampally, Pritam R; Damiano, Thomas; King, Christopher A

    2010-01-01

    The inferior phrenic arteries constitute a pair of important vessels, supplying multiple organs including the diaphragm, adrenal glands, esophagus, stomach, liver, inferior vena cava, and retroperitoneum. The vast majority (80-90%) of inferior phrenic arteries originate as separate vessels with near equal frequency from either the abdominal aorta or the celiac trunk. Infrequently, the right and left inferior phrenic arteries can arise in the form of a common trunk from the aorta or from the celiac trunk. We herein present three patients with a new anatomic vascular variant: a common trunk of the inferior phrenic arteries arising from the right renal artery. In one case, the left inferior phrenic branch of the common trunk provided collaterals connecting with a supra-diaphragmatic branch of the left internal mammary artery and in another with the lateral wall of the pericardium. Angiographic identification of a common trunk for the inferior phrenic arteries arising from the right renal artery is important for proper diagnosis and clinical management. The presence of this unique vascular variant can impact revascularization of the renal arteries. Published by Elsevier Inc.

  12. Concomitant Persistent Left Superior Vena Cava and Horseshoe Kidney

    Directory of Open Access Journals (Sweden)

    Faraz Jaffer

    2015-01-01

    Full Text Available Persistent left superior vena cava (PLSVC and horseshoe kidney (HSK are common congenital abnormalities; however presence of both in the same person is extremely rare. A patient with hepatitis C cirrhosis awaiting transplant presented with worsening liver dysfunction, diagnosed with acute renal failure secondary to hepatorenal syndrome, and required X-ray fluoroscopy guided tunneled venous catheter placement for hemodialysis. Review of imaging studies demonstrated coexistence of PLSVC and HSK. PLSVC in adulthood is usually incidental with the most common drainage pattern being without physiologic dysfunction. Isolated horseshoe kidney is still the most common of renal fusion anomalies; however etiology of coexistent PLSVC remains unknown.

  13. Leonardo da Vinci and Kethem-Kiveris vena.

    Science.gov (United States)

    Dolezal, Antonín; Skorepova-Honzlova, Zita; Jelen, Karel

    2012-01-01

    In the drawing of coitus by Leonardo da Vinci are pictured the contemporary hypotheses regarding this act. The authors analyze the mamillaruteral connection depicted by the artist and grow up to believe that this is a hypothetical kiveris vena, female vein described by Anatomist Master Nicolai Physicus from the Salerno School. The Hebrew roots were found in the name. The connection is described also by Mondino in The Anathomia. The same connection can be found in the picture of the pregnant woman in Fasciculus Medicinæ by Johannes De Ketham.

  14. Extreme premature with persistent left superior vena cava.

    Science.gov (United States)

    Aboitiz-Rivera, Carlos Manuel; Blachman-Braun, Ruben; Parra-Pérez, Mariana Yazmin

    2017-10-01

    Persistent left superior vena cava (PLSVC) is a congenital anomaly, that results when there is an absence of the normal regression of the left common precardinal vein during embryogenesis. Usually, this anomaly remains asymptomatic, however, when the PLSVC drains into the left atrium this could lead to a right-to-left shunt. Additionally, this can result in inadvertent delivery of air or thrombus into the systemic circulation with potential neurologic, cardiac and renal complications. In this article, we present a case of an extreme premature Mexican newborn in which the diagnosis was made after placement of a percutaneous central venues catheter.

  15. Long-Term Safety and Effectiveness of the “OptEase” Vena Cava Filter

    International Nuclear Information System (INIS)

    Kalva, Sanjeeva P.; Marentis, Theodore C.; Yeddula, Kalpana; Somarouthu, Bhanusupriya; Wicky, Stephan; Stecker, Michael S.

    2011-01-01

    Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evident filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 ± 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.

  16. Comparison of infection between internal-external and external percutaneous transhepatic biliary drainage in treating patients with malignant obstructive jaundice.

    Science.gov (United States)

    Xu, Chuan; Huang, Xin-En; Wang, Shu-Xiang; Lv, Peng-Hua; Sun, Ling; Wang, Fu-An

    2015-01-01

    Percutaneous transhepatic biliary drainage (PTBD) is a form of palliative care for patients with malignant obstructive jaundice. We here compared the infection incidence between internal-external and external drainage for patients with malignant obstructive jaundice. Patients with malignant obstructive jaundice without infection before surgery receiving internal-external or external drainage from January 2008 to July 2014 were recruited. According to percutaneous transhepatic cholangiography (PTC), if the guide wire could pass through the occlusion and enter the duodenum, we recommended internal-external drainage, and external drainage biliary drainage was set up if the occlusion was not crossed. All patients with infection after procedure received a cultivation of blood and a bile bacteriological test. Among 110 patients with malignant obstructive jaundice, 22 (52.4%) were diagnosed with infection after the procedure in the internal-external drainage group, whereas 19 (27.9%) patients were so affected in the external drainage group, the difference being significant (pinternal-external group infection was controlled, as compared to 12 (63.1%) in the external group (pinternal-external group in one month was 42.8%, while this rate in external group was 28.6% (pExternal drainage is a good choice, which could significantly reduce the chance of biliary infection caused by bacteria, and decrease the mortality rate at one month and improve the long-term prognosis.

  17. Fine-needle percutaneous transhepatic parenchymal portal venography by using carbon dioxide: a pilot study in pigs

    International Nuclear Information System (INIS)

    Sun, Fei; Hernandez, Javier; Crisostomo, Veronica; Pineda, Luis-Fernando; Lima, Juan Rafael; Uson, Jesus; Maynar, Manuel

    2003-01-01

    Our purpose was to evaluate the feasibility and safety of carbon dioxide (CO 2 ) in fine-needle percutaneous transhepatic parenchymal portal venography and its potential clinical applications. Three Belgian landrace pigs received fine-needle percutaneous transhepatic parenchymal portal venography by using CO 2 as a contrast agent. Under fluoroscopic and B-mode ultrasonic guidance, right or left lobe of liver was punctured with a 22-G Chiba needle, through which CO 2 was injected with a dedicated CO 2 injector at injection rate of 20 ml/s for 20 ml, 40 ml/s for 40 ml, 40 ml/s for 60 ml, and 40 ml/s for 80 ml, respectively. The portal venograms were obtained by use of digital subtraction angiography (DSA) system with animal in supine position. In one pig transarterial portal venography was performed, in addition, using iodinated contrast agent. The portal vein was visualized in each run of venography. Optimal images of portal tree structure up to four-order branches were obtained in all those with CO 2 injection rate of 40 ml/s, which appeared much better in quality than those obtained by cranial mesenteric arteriography with iodinated contrast agent. No extravasation of CO 2 , liver laceration, or any other complication occurred during the procedures. The technique we proposed demonstrated optimal portography, which appeared to be safe, minimally invasive, less time-consuming, cost-effective, and easy to perform, with great potential in clinical applications. (orig.)

  18. Hombre de 75 años con edemas y sangrado digestivo inferior A 75 years old man with edema and inferior gastrointestinal bleeding

    Directory of Open Access Journals (Sweden)

    Alberto Carlos Reino Buelvas

    2004-02-01

    Full Text Available Se presenta el caso de un hombre de 75 años, quien consultó por edemas generalizados originados en un síndrome nefrótico, secundario a una glomerulopatía clasificada como de cambios mínimos. Se le iniciaron esteroides con mejoría de su proteinuria, pero al disminuir las dosis de éstos, recayó, por lo que requirió nueva hospitalización en la que se le documentaron trombosis venosa profunda y sangrado por tracto gastrointestinal inferior. Se le implantó un filtro de vena cava inferior y se le practicó una colonoscopia, en la que se encontró poliposis coli. Al estudio histológico se reportó un linfoma no Hodgkin compatible con un linfoma del manto (poliposis linfomatoide versus linfoma marginal tipo MALT de bajo grado. The case of a 75 year old man is presented. He consulted because of generalized edema and the diagnosis of nephrotic syndrome was done. Histologic study of a renal biopsy reported a glomerulopathy of minimal changes. Treatment with steroids improved of proteinuria, but on reducing the doses, proteinuria returned. In a second hospitalization deep venous thrombosis and gastrointestinal bleeding were diagnosed. A cava vein filter was implanted, colonoscopy was performed and Polyposis Coli was found. A non Hodgkin lymphoma compatible with MANTLE CELL lymphoma (lymphomatous polyposis vs MALT lymphoma was reported in the colonic biopsy.

  19. Porto-systemic collaterals in cirrhosis of the liver. Selective percutaneous transhepatic catheterization of the portal venous system in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Hoevels, J; Lunderquist, A; Tylen, U; Simert, G [Lund Univ. (Sweden)

    1979-01-01

    In 93 patients with cirrhosis of the liver and portal venous hypertension the main tributaries of the portal vein were examined by percutaneous transhepatic catheterization. The appearance and degree of porto-systemic collaterals were analysed. Esophageal varices were demonstrated in 82 patients. No correlation was found between the portal venous pressure and the extent of porto-systemic communications.

  20. The clinical application of ultrasonography-guided percutaneous transhepatic injection of iodized oil containing chemotherapeutic agent for the treatment of hilar lymphatic metastasis

    International Nuclear Information System (INIS)

    Zhao Guangsheng; Zhang Yuewei; Yang Xiaohong; Li Chuang; Zhao Mu; Wang Wenqing; Wang Ruoyu

    2010-01-01

    Objective: To discuss the technique and the clinical effect of ultrasonography-guided percutaneous transhepatic injection of iodized oil containing chemotherapeutic agent for the treatment of hepatic hilar lymphatic metastasis. Methods: Under ultrasonographic guidance,percutaneous transhepatic injection of iodized oil containing chemotherapeutic agent, so-called chemo-ablation, into the diseased lymph nodes was performed in thirteen patients with hepatic hilar lymphatic metastasis. The therapeutic results were evaluated based on the post-operative imaging examinations as well as the alleviation of the clinical symptoms. Results: Percutaneous transhepatic injection of iodized oil containing chemotherapeutic agent into the diseased lymph nodes was successfully carried out in all thirteen patients. After the procedure,the patients were followed up for a mean period of 13.5 months. The therapeutic effectiveness was 100%, while the regression rate of the lesions was 76.9%. No operation-related complications occurred. Conclusion: Percutaneous transhepatic injection of iodized oil containing chemotherapeutic agent into the diseased lymph nodes under ultrasonographic guidance is an effective and safe treatment for hepatic hilar lymphatic metastasis with reliable effectiveness. (authors)

  1. Risk Factors for Immediate and Delayed-Onset Fever After Percutaneous Transhepatic Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Lucatelli, Pierleone, E-mail: pierleone.lucatelli@gmail.com [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological, Oncological and Anatomo-pathological Sciences (Italy); Corradini, Stefano Ginanni, E-mail: stefano.corradini@uniroma1.it [Sapienza University of Rome, Gastroenterology Division, Department of Clinical Medicine (Italy); Corona, Mario, E-mail: mario.corona@uniroma1.it; Corradini, Luca Ginanni, E-mail: lucagino@hotmail.it; Cirelli, Carlo, E-mail: dottcirelli@gmail.com [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological, Oncological and Anatomo-pathological Sciences (Italy); Saba, Luca, E-mail: lucasabamd@gmail.com [Azienda Ospedaliero Universitaria (A.O.U.) of Cagliari-Polo di Monserrato, Department of Medical Imaging (Italy); Poli, Edoardo, E-mail: edoardo.poli88@gmail.com [Sapienza University of Rome, Gastroenterology Division, Department of Clinical Medicine (Italy); Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological, Oncological and Anatomo-pathological Sciences (Italy); Wang, Haofan, E-mail: wanghaof@mail.sysu.edu.cn [Department of Vascular Interventional Radiology of the 3rd Affiliated Hospital of Sun Yat-sen University (China); Bezzi, Mario, E-mail: mario.bezzi@uniroma1.it; Catalano, Carlo, E-mail: carlo.catalano@uniroma1.it [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological, Oncological and Anatomo-pathological Sciences (Italy)

    2016-05-15

    ObjectivesTo prospectively investigate the pre and intra-procedural risk factors for immediate (IF) and delayed-onset (DOF) fever development after percutaneous transhepatic biliary drainage (PTBD).MethodsInstitutional review board approval and informed patient consent were obtained. Between February 2013 and February 2014, 97 afebrile patients (77 at the Sapienza University of Rome, Italy and 20 at the Sun Yat-sen University of Guangzhou, China) with benign (n = 31) and malignant (n = 66) indications for a first PTBD were prospectively enrolled. Thirty pre- and intra-procedural clinical/radiological characteristics, including the amount of contrast media injected prior to PTBD placement, were collected in relation to the development of IF (within 24 h) or DOF (after 24 h). Fever was defined as ≥37.5 °C. Binary logistic regression analysis was used to assess independent associations with IF and DOF.ResultsFourteen (14.4 %) patients developed IF and 17 (17.5 %) developed DOF. At multivariable analysis, IF was associated with pre-procedural absence of intrahepatic bile duct dilatation (OR 63.359; 95 % CI 2.658–1510.055; P = 0.010) and low INR (OR 4.7 × 10{sup −4}; 95 % CI 0.000–0.376; P = 0.025), while DOF was associated with unsatisfactory biliary drainage at the end of PTBD (OR 4.571; 95 % CI 1.161–17.992; P = 0.030).ConclusionsThe amount of contrast injected is not associated with post-PTBD fever development. Unsatisfactory biliary drainage at the end of PTBD is associated with DOF, suggesting that complete biliary tree decompression should be pursued within the first PTBD. Patients with unsatisfactory drainage and those with the absence of pre-procedural intrahepatic bile duct dilatation, which is associated with IF, require tailored post-PTBD management.

  2. Percutaneous transhepatic biliary drainage through the normal duct in patients with post-operative bile leakage

    International Nuclear Information System (INIS)

    Lee, Hyun; Kim, Young Hwan; Kim, Yong Joo

    2004-01-01

    To evaluate the technical feasibility and clinical efficacy of percutaneous transhepatic biliary drainage (PTBD) through the normal duct in patients with post-operative bile leakage. From January 1998 to December 2003, fourteen patients (male: 12, female: 2, mean age: 56) with biliary leak after laparoscopic cholecystectomy (n = 5), T-tube removal (n = 5), choledochojejunostomy due to small bowel perforation (n = 1), right lobectomy (n = 1), laparoscopic adrenalectomy (n = 1), and subtotal gastrectomy (n = 1) were treated by means of PTBD; this was performed with the two-step approach. The central bile duct was cannulated using a 21-G Chiba needle to map the intrahepatic biliary tree. An 8.5-F drainage catheter tip was positioned at the CBD after puncturing peripheral bile duct with an additional Chiba needle. We evaluated the technical feasibility, the procedure-related complications, clinical efficacy and the duration of catheter placement. PTBD of the normal duct with the two-step approach was successful in all but two cases. In these two cases, the two-step approach was failed due to the rapid disappearance of the targeted peripheral duct, and this was the result caused by biloportal fistula. PTBD was performed through the central bile duct in one patient, and through the remnant cystic duct in one patient. There were no procedure-related complications except for mild abdominal pain in seven patients. Bile leakage was demonstrated on cholangiogram in 10 of 14 patients; this occurred at the T-tube exit site (n = 4), cystic duct stump (n = 2), choledochojejunostomy site (n = 1), resection margin of liver (n = 1), caudate lobe (n = 1), and GB bed (n = 1). In 13 patients, the biliary leak stopped after drainage (mean duration: 32.1 days). In one patient, surgical management was performed one day after PTBD due to the excessive amount of bile leakage. PTBD is a technically feasible and clinically efficacious treatment for post-operative bile leakage, and it can

  3. Risk Factors for Immediate and Delayed-Onset Fever After Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    Lucatelli, Pierleone; Corradini, Stefano Ginanni; Corona, Mario; Corradini, Luca Ginanni; Cirelli, Carlo; Saba, Luca; Poli, Edoardo; Fanelli, Fabrizio; Wang, Haofan; Bezzi, Mario; Catalano, Carlo

    2016-01-01

    ObjectivesTo prospectively investigate the pre and intra-procedural risk factors for immediate (IF) and delayed-onset (DOF) fever development after percutaneous transhepatic biliary drainage (PTBD).MethodsInstitutional review board approval and informed patient consent were obtained. Between February 2013 and February 2014, 97 afebrile patients (77 at the Sapienza University of Rome, Italy and 20 at the Sun Yat-sen University of Guangzhou, China) with benign (n = 31) and malignant (n = 66) indications for a first PTBD were prospectively enrolled. Thirty pre- and intra-procedural clinical/radiological characteristics, including the amount of contrast media injected prior to PTBD placement, were collected in relation to the development of IF (within 24 h) or DOF (after 24 h). Fever was defined as ≥37.5 °C. Binary logistic regression analysis was used to assess independent associations with IF and DOF.ResultsFourteen (14.4 %) patients developed IF and 17 (17.5 %) developed DOF. At multivariable analysis, IF was associated with pre-procedural absence of intrahepatic bile duct dilatation (OR 63.359; 95 % CI 2.658–1510.055; P = 0.010) and low INR (OR 4.7 × 10"−"4; 95 % CI 0.000–0.376; P = 0.025), while DOF was associated with unsatisfactory biliary drainage at the end of PTBD (OR 4.571; 95 % CI 1.161–17.992; P = 0.030).ConclusionsThe amount of contrast injected is not associated with post-PTBD fever development. Unsatisfactory biliary drainage at the end of PTBD is associated with DOF, suggesting that complete biliary tree decompression should be pursued within the first PTBD. Patients with unsatisfactory drainage and those with the absence of pre-procedural intrahepatic bile duct dilatation, which is associated with IF, require tailored post-PTBD management.

  4. Hemiazygos continuation of v.cava inferior: a case report

    International Nuclear Information System (INIS)

    Incedayi, M.; Aribal, S.; Sivrioglu, A.; Kara, K.

    2012-01-01

    Full text: A 78-year-old female patient was suffering from dyspnoea and tachypnoea in our hospital's orthopaedic clinic. Because she had an operation of right femoral mid-diaphizer fracture a week ago, we decided to perform a pulmonary computerized tomography angiography (CTA) examination with her clinicians in order to evaluate a possible pulmonary embolism and to make a further evaluation. In her CTA exam there were no pulmonary embolism was seen. There were some chronic changes in her lungs, bilateral pleural effusion and hilar lymphadenomagalies. A dilated and tortiozed vascular structure which was retrocrural and retroaortic placed at the level of the thorachoabdominal transition and joined to left brachiocephalic vein was seen. Then we realized that the liver was symmetrical and transverse localization the upper abdomen and the stomach and spleen was in the right upper quadrant. Because the cardiac apex was left-sided we decided that a kind of situs ambiguous. After that the patient was underwent a abdominal contrast enhanced CT which was including the both arterial and venous phases. In this examination the suprarenal part of the inferior vena cava (IVC) was interrupted and it was continuing as hemiazygos vein to the thorax something like the previous CT exam. The hepatic veins were drained into a short segment vein and then the right atrium. Multiple nodular parenchymal images which were enhanced like spleen in all phases were seen in right upper quadrant of the abdomen (polysplenia). And also partial agenesis of the pancreas and annular pancreas configuration was seen. Anomalies of the IVC occur rarely and the patient are usually asymptomatic. Non-invasive imaging modalities such as CT and MRI allow better identification of these anomalies. In these cases different organ anomalies accompanies the IVC anomalies

  5. Design of a new biodegradable vena cava filter%新型生物可降解腔静脉滤器的设计研究

    Institute of Scientific and Technical Information of China (English)

    赵辉; 张福先; 李海磊; 张欢

    2015-01-01

    handmade,and consisted of two parts:the cone was constructed of six polyglycolic acid polymer strands anchored to a handmade absorbable stent.Central inferior vena cava fixation were accomplished by the absorbable stent which was made of polycaprolactone.The filters were inserted to the inferior vena cava of ten dogs under ultrasound guidance.The filters were operatively retrieved at 6 weeks after implantation .The inferior vena cava were subsequently analyzed using light microscopy. The lungs were also removed to observe any pulmonary embolism caused by the degradation products of the biodegradable filter.Results Biodegradable vena cava filters were successfully made and implanted in 1 0 adult dogs.None of the 1 0 dogs had abnormal vital signs except one dog had lower extremity swelling.① Migration:All the filters migrated cephalad.One filter migrated into the right atrioventricular orifice,the other 9 filters migrated cephalad approximately <2 cm and remained below the renal vein ostia.②Naked-eye observation:In 8 of the 9 remaining filters,the absorbable strands had completely dissolved.One specimen had evidence of incorporated residual strands within the caval wall on gross examination,resulting in 70%stenosis of inferior vena cava.All of the biodegradable stents were embedded into the caval wall.The caval wall became thick at the level of filter placement without significant lumen narrowing.③ Hematoxylin and eosin (HE)staining:Intense inflammatory response with significant thickened intima and media was seen on HE staining.There was no evidence of pulmonary embolism or inflammatory response caused by degradation products of the absorbable strands.Conclusion We had designed a biodegradable inferior vena cava filter successfully,the biodegradability and biocompability had been proven through in vivo studies.

  6. False-positive liver scans due to portal hypertension: correlation with percutaneous transhepatic portograms in 33 patients

    International Nuclear Information System (INIS)

    Takayasu, K.; Moriyama, N.; Suzuki, M.; Yamada, T.; Fukutake, T.; Shima, Y.; Kobayashi, C.; Musha, H.; Okuda, K.

    1983-01-01

    Tc-99m-phytate scanning of the liver and percutaneous transhepatic catheterization of the portal vein were performed in 33 patients--26 with cirrhosis, 3 with chronic active hepatitis, 2 with idiopathic portal hypertension, and 2 with unresolved acute hepatitis. A discrete defect in the porta hepatis area was seen in 6 of 28 patients who had portal vein pressure above 200 mm H2O. In 5 of the 6 patients with a false-positive scan, the umbilical portion of the left portal vein branch was dilated (larger than 25 x 20 mm) on the portogram, with or without a patent paraumbilical vein. The anatomical basis of this phenomenon is discussed, and it is suggested that this area be given special attention

  7. Evaluation of gradual occlusion of the caudal vena cava in clinically normal dogs.

    Science.gov (United States)

    Peacock, John T; Fossum, Theresa W; Bahr, Anne M; Miller, Matthew W; Edwards, John F

    2003-11-01

    To devise a technique for gradual occlusion of the caudal vena cava in dogs and determine effects of complete occlusion of the caudal vena cava. 8 mixed-breed hounds that weighed between 25 and 30 kg. Baseline evaluation of dogs included serum biochemical analyses and determination of glomerular filtration rate (GFR) with dynamic renal scintigraphy and plasma clearance analysis. An occluder was placed around the vena cava in the region cranial to the renal veins. The occluder was attached to a vascular access port. The vena cava was gradually occluded over 2 weeks. The GFR was measured every 2 weeks after surgery, and venograms were performed every 3 weeks after surgery. Blood samples were collected every 48 hours for the first week and then weekly thereafter to measure BUN and creatinine concentrations and activities of alanine transaminase, alkaline phosphatase, and creatinine kinase. Dogs were euthanatized 6 weeks after surgery, and tissues were submitted for histologic examination. The GFR and biochemical data were compared with baseline values. Gradual occlusion of the caudal vena cava was easily and consistently performed with this method, and adverse clinical signs were not detected. Formation of collateral vessels allowed overall GFR to remain constant despite a decrease in function of the left kidney. Measured biochemical values did not deviate from reference ranges. Gradual occlusion of the caudal vena cava may allow removal of adrenal gland tumors with vascular invasion that would otherwise be difficult or impossible to resect.

  8. Multidetector row computed tomography and ultrasound characteristics of caudal vena cava duplication in dogs.

    Science.gov (United States)

    Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco

    2014-01-01

    Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.

  9. Tuberculosis pulmonar de campos inferiores

    Directory of Open Access Journals (Sweden)

    Alejandra González

    2010-10-01

    Full Text Available La tuberculosis (TB que compromete sólo los campos pulmonares inferiores (TBCI es poco frecuente en el adulto y en general está asociada a alguna causa de inmunodepresión. El objetivo de nuestro trabajo fue determinar la incidencia de TBCI en nuestra población y comparar sus características respecto de la TB pulmonar de localización habitual. Se estudiaron en forma retrospectiva en el período de 2004 a 2008, 42 pacientes con TBCI que fueron comparados con 84 pacientes con TB pulmonar de localización habitual (grupo control. Se excluyeron pacientes con HIV. La TBCI representó el 6% del total de TB pulmonar. No se encontraron diferencias significativas en cuanto a edad, sexo, presencia de cavidades en la radiografía, días de evolución y nivel de albúmina. La TBCI tuvo significativamente mayor proporción de comorbilidades (p < 0.001, presencia de condensación (p < 0.001 y compromiso unilateral (p < 0.001 en la radiografía de tórax, junto con mayor número de internaciones (p = 0.02. Cabe destacar que sólo16 de los 42 pacientes con TBCI (38% tenían alguna comorbilidad demostrada. La TBCI puede presentarse aun sin comorbilidades asociadas y debe sospecharse en neumonías de evolución tórpida independientemente de su localización.

  10. Inferior alveolar nerve block: Alternative technique.

    Science.gov (United States)

    Thangavelu, K; Kannan, R; Kumar, N Senthil

    2012-01-01

    Inferior alveolar nerve block (IANB) is a technique of dental anesthesia, used to produce anesthesia of the mandibular teeth, gingivae of the mandible and lower lip. The conventional IANB is the most commonly used the nerve block technique for achieving local anesthesia for mandibular surgical procedures. In certain cases, however, this nerve block fails, even when performed by the most experienced clinician. Therefore, it would be advantageous to find an alternative simple technique. The objective of this study is to find an alternative inferior alveolar nerve block that has a higher success rate than other routine techniques. To this purpose, a simple painless inferior alveolar nerve block was designed to anesthetize the inferior alveolar nerve. This study was conducted in Oral surgery department of Vinayaka Mission's dental college Salem from May 2009 to May 2011. Five hundred patients between the age of 20 years and 65 years who required extraction of teeth in mandible were included in the study. Out of 500 patients 270 were males and 230 were females. The effectiveness of the IANB was evaluated by using a sharp dental explorer in the regions innervated by the inferior alveolar, lingual, and buccal nerves after 3, 5, and 7 min, respectively. This study concludes that inferior alveolar nerve block is an appropriate alternative nerve block to anesthetize inferior alveolar nerve due to its several advantages.

  11. Traumatismos de veia cava inferior

    Directory of Open Access Journals (Sweden)

    Cleinaldo de Almeida Costa

    Full Text Available OBJETIVO: Avaliar a incidência, o perfil clínico e as estratégias operatórias dos ferimentos de Veia Cava Inferior (VCI. MÉTODOS: Foram analisados retrospectivamente os prontuários de 76 doentes com ferimento de VCI atendidos nos dois prontossocorros de Manaus, no período de janeiro de 1997 a julho de 2002. Mecanismo de lesão, mortalidade, estado hemodinâmico, índice de trauma abdominal penetrante (PATI, achados intra-operatórios e conduta cirúrgica foram estudados. RESULTADOS: Quarenta e nove (65% doentes sofreram lesão por arma branca, 26 (34% por arma de fogo e um por traumatismo abdominal fechado. Quarenta e um (54% doentes sobreviveram. Quase todos chegaram acordados, entretanto 40% estavam hipotensos (pressão arterial sistólica < 70mmHg. O índice de trauma abdominal penetrante (PATI médio foi maior que 40. À laparotomia, todos demonstraram sangramento retroperitoneal ativo ou hematoma retroperitoneal em expansão. Vinte e um pacientes possuíam lesão de VCI retro-hepática, enquanto nos outros 55 a lesão era infra-hepática. O reparo operatório predominante foi a venorrafia lateral em 65 doentes. Houve necessidade de tóraco-freno-laparotomia em quatro doentes do total de oito doentes que foram à toracotomia direita por lesão retro-hepática. Foram realizados shunts átrio-cavais em seis doentes, dos quais três sobreviveram. CONCLUSÕES: O ferimento de VCI é uma lesão de alta letalidade e possui uma relação intrínseca com a violência urbana. A sobrevivência depende de uma imediata e vigorosa reposição de volume, um manejo operatório adequado e todo esforço em evitar-se hipotermia.

  12. Efficacy and safety of radiofrequency ablation of hepatocellular carcinoma in the hepatic dome with the CT-guided extrathoracic transhepatic approach

    International Nuclear Information System (INIS)

    Kim, Young Kon; Kim, Chong Soo; Lee, Jeong Min; Chung, Gyung Ho; Chon, Su Bin

    2006-01-01

    Purpose: The purpose of this study was to determine the efficacy and safety of radiofrequency (RF) ablation for the treatment of hepatocellular carcinoma (HCC) in the hepatic dome with CT-guided extrathoracic transhepatic approach. Materials and methods: Fifteen patients with 15 HCCs (size range: 0.8-4 cm, mean size: 1.8 cm) in the hepatic dome were treated by RF ablation using cooled-tip electrodes and with CT-guided extrathoracic transhepatic approach. Therapeutic response of the tumor to RF ablation and procedure-related complications including hepatic injury, hemoperitoneum, and thermal injury of diaphragm were evaluated. Results: The average number of needle punctures to ensure the correct needle position in the targeted tumor was 3.7 (range: 1-6 punctures). The average ablation time was 14.7 min (range: 8-25 min). Complete necrosis without marginal recurrence after at least 13-month follow-up was attained in 13 tumors (86.7%). There were no major complications related to the procedures. Six patients had shoulder pain that lasted three days to two weeks after the procedures and their symptoms were resolved with conservative treatment. Conclusions: RF ablation using CT-guided extrathoracic transhepatic approach is an effective and safe technique for the treatment of HCC in the hepatic dome

  13. Evaluation of Retrievability of the Gunther Tulip Vena Cava Filter

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko

    2007-01-01

    Purpose. To evaluate the feasibility and safety of withdrawal of a Gunther tulip retrievable vena cava filter (GTF). Methods. Between June 2001 and December 2005, at our institution 86 GTFs were implanted for temporary caval filtration in 59 patients (37 women, 22 men; mean age 59.3 years, range 18-87 years). For GTFs retrieved thereafter, we retrospectively reviewed the following parameters: rate of success in retrieval, degree of trapped thrombus in the filter, and complications during retrieval. Results. Worsening of or new development of pulmonary embolism after filter implantation did not occur in any patient. Of the 86 GTFs implanted, retrieval of 80 was attempted. Among those 80 filters, 77 (96%) were successfully retrieved (with the standard method, n = 72; with the modified method, n = 5) without any complication. The period of implantation of the retrieved filters was 13.4 ± 4.2 days. In the 5 filters that were filled to a height of ≥ 1/4 with trapped thrombus, retrieval was performed after attempts were made to decrease trapped thrombi. In addition, a temporary filter or another GTF was temporarily placed at the cephalad level of the GTF during this removal procedure. Conclusion. GTFs can be retrieved in the majority of cases. Even when encountering situations in which the filter could not be removed using the standard method, withdrawal was possible in a high frequency of cases through various trials using modified methods

  14. Radiographic evaluation of caudal vena cava size in dogs

    International Nuclear Information System (INIS)

    Lehmkuhl, L.B.; Bonagura, J.D.; Biller, D.S.; Hartman, W.M.

    1997-01-01

    Dilation of the caudal vena cava (CVC) on lateral thoracic radiographs is often interpreted as suggestive of right-sided congestive heart failure, To quantitate the clinical utility of evaluating CVC size as an indicator of right-sided heart disease, we compared the ratio of the diameter of the CVC as measured on a left lateral thoracic radiograph to the descending aorta (Ao), length of the thoracic vertebra above the tracheal bifurcation (VL), and width of the right fourth rib (R4) in 35 dogs with right heart disease and 35 control dogs, Each CVC ratio(CVC/Ao, CVC/VL, CVC/R4) was statistically larger in dogs with right heart disease, Response operating characteristic curves and likelihood ratios were used to determine ratios helpful in identifying dogs with right heart disease. A CVC/Ao > 1.50, CVC/VL > 1.30, or CVC/R4 > 3.50 are strongly suggestive of a right-sided heart abnormality in a patient

  15. Superior versus inferior Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Pakravan, Mohammad; Yazdani, Shahin; Shahabi, Camelia; Yaseri, Mehdi

    2009-02-01

    To compare the efficacy and safety of Ahmed glaucoma valve (AGV) (New World Medical Inc., Rancho Cucamonga, CA) implantation in the superior versus inferior quadrants. Prospective parallel cohort study. A total of 106 eyes of 106 patients with refractory glaucoma. Consecutive patients with refractory glaucoma underwent AGV implantation in the superior or inferior quadrants. Main outcome measures included intraocular pressure (IOP) and rate of complications. Other outcome measures included best corrected visual acuity (BCVA), number of glaucoma medications, and success rate (defined as at least 30% IOP reduction and 5glaucoma surgery, phthisis bulbi, or loss of light perception. Of a total of 106 eyes, 58 and 48 eyes underwent AGV implantation in the superior and inferior quadrants, respectively. Baseline characteristics were comparable in the study groups, except for preoperative IOP, which was higher in the superior group (P = 0.01). Patients were followed for a mean period of 10.6+/-8.49 months and 10.58+/-6.75 months in the superior and inferior groups, respectively (P = 0.477). BCVA was comparable between the groups at all postoperative visits (P>0.122). After 1 year, statistically significant but comparable IOP reduction from baseline (Pglaucoma medications was comparable after 1 year (1.3+/-1.2 vs. 1.9+/-0.8 for superior and inferior implants, respectively, P = 0.256). Success rates were also similar at 1 year: 27 eyes (81.8%) versus 20 eyes (95.2%) for superior and inferior implants, respectively (P = 0.227). However, the overall rate of complications, such as implant exposure necessitating removal, cosmetically unappealing appearance, and endophthalmitis, was higher in the inferior group: 12 eyes (25%) versus 3 eyes (5.2%) for superior and inferior groups, respectively, (P = 0.004). Superior and inferior AGV implants have similar intermediate efficacy in terms of IOP reduction, decrease in number of glaucoma medications, and preservation of vision. However

  16. Neuroimaging findings in neonates and infants from superior vena cava obstruction after cardiac operation

    International Nuclear Information System (INIS)

    Karmazyn, Boaz; Horev, Gadi; Kornreich, Liora; Dagan, Ovdi; Vidne, Bernado A.

    2002-01-01

    Extraventricular obstructive hydrocephalus may develop after superior vena cava obstruction, an uncommon complication after cardiac surgery.Objective. To describe the neuroimaging findings in neonates and infants with superior vena cava thrombosis after cardiac surgery for congenital heart disease.Materials and methods. Between 1993 and 2001, 333 neonates and infants in our hospital underwent cardiac surgery, of whom 13 (3.9%) subsequently acquired superior vena cava syndrome. Eleven of these 13 children (7 boys, 4 girls) were evaluated by head ultrasound and computed tomography scans.Results. One child had normal findings on head ultrasound, and 10 children had extraventricular obstructive hydrocephalus (EVOH). In 6 children, aggravation of the hydrocephalus was noted up to 11.4 months after cardiac surgery; in 3 of them, the hydrocephalus was shunted to the peritoneum. One child had thrombosis of the dural sinuses, and 1 had hemorrhagic infarction. Two children died during follow-up.Conclusion. EVOH is a common complication of superior vena cava thrombosis, and head ultrasound should be performed in all neonates and infants with superior vena cava thrombosis after cardiac surgery. Long-term follow-up is needed, as the hydrocephalus may worsen even months after surgery. (orig.)

  17. Computed tomographic characteristics of collateral venous pathways in dogs with caudal vena cava obstruction.

    Science.gov (United States)

    Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna

    2014-01-01

    Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.

  18. Percutaneous treatment of superior vena cava syndrome using metallic stents

    International Nuclear Information System (INIS)

    De Gregorio Ariza, Miguel Angel; Gimeno, Maria Jose; Alfonso, Eduardo; Mainar, Antonio; Medrano, Joaquin; Lopez-Marin, Paloma; Gamboa, Pablo; Tobio, Ricardo; Herrera, Marcos

    2003-01-01

    The purpose of this study was to evaluate the results of treatment of superior vena cava syndrome (SVCS) in patients with benign and malignant disease using expandable metallic stent. From January 1995 to April 2000, 87 expandable stents were implanted in 82 patients (59 men, 23 women; mean age 57.8 years, age range 39-79 years) for the treatment of SVCS. The SVCS was defined as symptomatic bilateral obstruction of venous drainage from head, neck and upper extremities. In 68 patients SVCS was due to malignant neoplasia, and in 14 cases it was due to benign aetiology. All patients were treated with expandable stent. We implanted 81 Wallstent prostheses and 6 Palmaz stents. Adjuvant thrombolysis was applied in 12 patients who required fibrinolysis. After recanalization, the stent was implanted in all cases in SVC (infra- or supra-azygos vein). All patients were treated with heparin of low molecular weight (HBPM) during 6 months. Patency was analyzed according to clinical symptoms and Doppler US or venograms exploration. Technical success was observed in all cases. Clinical success was reached in 78 of 82 patients (95.1%) (absence of symptoms in 2 or 3 days). Four patients suffered immediate thrombosis which required fibrinolitic treatment with a new prosthesis placement in 1 case. The follow-up for the malignant process was of 7.1 months (range 1-39 months) and in benign cases was 31.2 months (range 11-61 months). Sixty-two (91.1%) patients with malignancy died without SVCS symptomatology. All the patients with benign pathology are alive. Clinical primary patency in malignant cases was 87% with assisted patency of 96.2%. Endovascular therapy using metallic stent and thrombolysis is a successful method to treat SVCS due to benign or malignant aetiology. (orig.)

  19. Unusual caudal vena cava thrombosis in a cow, secondary to Trueperella (Arcanobacterium pyogenes infection

    Directory of Open Access Journals (Sweden)

    Rodrigo Garcia Motta

    Full Text Available Abstract: The caudal vena cava thrombosis, or pulmonary thromboembolism, in cattle is correlated with lactic acidosis, caused by diets rich in grains and highly fermentable, associated or not to septic situations, used in feedlots of beef or high-producing dairy cattle. This paper reports an unusual caudal vena cava thrombosis in a cow, secondary to Trueperella (Arcanobacterium pyogenes infection, resulting in reduced milk production, anorexia, pale mucous membranes, ruminal atony, sternal decubitus and autoauscultation position. The heart was enlarged at necropsy, presence of clots distributed along the thoracic cavity, adherence between lung and pleura, abscesses, emphysema, petechiae, suffusions and ecchymosis in lungs, thickening of the caudal vena cava wall, hepatomegaly with chronic passive congestion ("nutmeg" aspect, and rumenitis. In lab, the actinomycete Trueperella (Arcanobacterium pyogenes was isolated from liver and lung samples, probably resulting through dissemination of the bacteria of the rumen content, what reaffirms the opportunistic behavior of this actinomycete.

  20. Transhepatic Balloon Dilatation of Early Biliary Strictures in Pediatric Liver Transplantation: Successful Initial and Mid-Term Outcome

    International Nuclear Information System (INIS)

    Belenky, Alexander; Mor, Eytan; Bartal, Gabriel; Atar, Eli; Shapiro, Riki; Bar-Nathan, Nathan; Bachar, Gil N.

    2004-01-01

    Purpose: To evaluate the initial and mid-term outcomes of transhepatic balloon dilatation for the treatment of early biliary strictures in lateral left-segment liver transplants in young children.Methods: Between April 1997 and May 2001, seven children aged 9 months to 6 years with nine benign strictures in left-segment liver grafts were treated percutaneously. Sessions of two or three dilations were performed three or four times at average intervals of 10-20 days. In each session, the biliary stenoses were gradually dilated using balloons of 3-7 mm. Follow-up ranged from 12 to 54 months (mean 27 months, median 12 months). Clinical success was defined as resolution of the stenosis, normalization of liver enzymes and lack of clinical symptoms. Results: Technical success was achieved in all nine strictures. Hemobilia occurred in one patient and was successfully treated. On follow-up, all patients had complete clinical recovery with normalization of liver function and imaging of patent bile ducts. Conclusion: Balloon dilatation is an effective and relatively safe method for the treatment of early biliary strictures in left-segment liver transplantation in young children. We recommend this approach as the initial treatment for early strictures. Metal stents or surgery should be reserved for patients with late appearance of strictures or failure of balloon dilatation

  1. Computed tomographic diagnosis for hepatofugal collaterals in portal hypertension. Comparative study of CT with percutaneous transhepatic portography

    Energy Technology Data Exchange (ETDEWEB)

    Iida, Akihiko; Sano, Akira; Imanaka, Kazufumi; Nishizawa, Sadahiko; Sasai, Keisuke

    1984-08-01

    This paper deals with the diagnostic capability of CT scan for hepatofugal collaterals in 22 patients with portal hypertension. The patients studied were those who underwent percutaneous transhepatic portography (PTP) and CT scan within a short period. Each collateral vein demonstrated by PTP was classified into three grades according to its caliber (d): (1) Grade I, d<5mm, (2) Grade II, 5mm

  2. US-guided percutaneous transhepatic biliary drainage: comparative study of right-sided and left-sided approach

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Cha, Soon Joo

    2002-01-01

    To compare the feasibility and safety of US-guided right and left percutaneous transhepatic biliary drainage (PTBD). Between March 1998 and May 1999, 32 patients underwent 36 US-guided right or left PTBD in referred order, alternatively. The causes of biliary obstruction were bile duct stone (n=2), bile duct carcinoma (n=10), carcinoma of the pancreas (n=9), GB carcinoma (n=7), metastasis to the porta hepatis (n=3), and carcinoma of the ampulla of vater (n=1). Technical success, procedure time, fluoroscopic time, and complications were evaluated. PTBD was successful in 94% of both right and left approach. The average procedure time was 9.7 ±3.8 min. in the right approach and 9.6 ±3.1 min. in the left approach, respectively (p=0.794). The average fluoroscopic time were 3.9±2.4 min. in the right approach and 3.8±2.2 min. in the left approach (p=0.892). A major complication, bile peritonitis, occurred in one of 16 patient with right-sided approach. Minor complications occurred in six right (2 hemobilia, 3 tube malfunction, 1 cholangitis) and three left (1 hemobilia, 1 fever, 1cholangitis) PTBD. There were no significant difference in the complication rates between right and left PTBD (p=0.729). There were no significant differences in feasibility and safety in US-guided right and left PTBD

  3. Percutaneous transhepatic vs. endoscopic retrograde biliary drainage for suspected malignant hilar obstruction: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Al-Kawas, Firas; Aslanian, Harry; Baillie, John; Banovac, Filip; Buscaglia, Jonathan M; Buxbaum, James; Chak, Amitabh; Chong, Bradford; Coté, Gregory A; Draganov, Peter V; Dua, Kulwinder; Durkalski, Valerie; Elmunzer, B Joseph; Foster, Lydia D; Gardner, Timothy B; Geller, Brian S; Jamidar, Priya; Jamil, Laith H; Keswani, Rajesh N; Khashab, Mouen A; Lang, Gabriel D; Law, Ryan; Lichtenstein, David; Lo, Simon K; McCarthy, Sean; Melo, Silvio; Mullady, Daniel; Nieto, Jose; Bayne Selby, J; Singh, Vikesh K; Spitzer, Rebecca L; Strife, Brian; Tarnaksy, Paul; Taylor, Jason R; Tokar, Jeffrey; Wang, Andrew Y; Williams, April; Willingham, Field; Yachimski, Patrick

    2018-02-14

    The optimal approach to the drainage of malignant obstruction at the liver hilum remains uncertain. We aim to compare percutaneous transhepatic biliary drainage (PTBD) to endoscopic retrograde cholangiography (ERC) as the first intervention in patients with cholestasis due to suspected malignant hilar obstruction (MHO). The INTERCPT trial is a multi-center, comparative effectiveness, randomized, superiority trial of PTBD vs. ERC for decompression of suspected MHO. One hundred and eighty-four eligible patients across medical centers in the United States, who provide informed consent, will be randomly assigned in 1:1 fashion via a web-based electronic randomization system to either ERC or PTBD as the initial drainage and, if indicated, diagnostic procedure. All subsequent clinical interventions, including crossover to the alternative procedure, will be dictated by treating physicians per usual clinical care. Enrolled subjects will be assessed for successful biliary drainage (primary outcome measure), adequate tissue diagnosis, adverse events, the need for additional procedures, hospitalizations, and oncological outcomes over a 6-month follow-up period. Subjects, treating clinicians and outcome assessors will not be blinded. The INTERCPT trial is designed to determine whether PTBD or ERC is the better initial approach when managing a patient with suspected MHO, a common clinical dilemma that has never been investigated in a randomized trial. ClinicalTrials.gov, Identifier: NCT03172832 . Registered on 1 June 2017.

  4. Endoscopic Biliary Stenting Versus Percutaneous Transhepatic Biliary Stenting in Advanced Malignant Biliary Obstruction: Cost-effectiveness Analysis.

    Science.gov (United States)

    Sun, Xin Rong; Tang, Cheng Wu; Lu, Wen Ming; Xu, Yong Qiang; Feng, Wen Ming; Bao, Yin; Zheng, Yin Yuan

    2014-05-01

    This study aims to compare the clinical outcomes and costs between endoscopic biliary stenting (EBS) and percutaneous transhepatic biliary stenting (PTBS). We randomly assigned 112 patients with unresectable malignant biliary obstruction 2006 and 2011 to receive EBS or PTBS with self-expandable metal stent (SEMS) as palliative treatment. PTBS was successfully performed in 55 patients who formed the PTBS group (failed in 2 patients). EBS was successfully performed in 52 patients who formed the EBS group (failed in 3 patients). The effectiveness of biliary drainage, hospital stay, complications, cost, survival time and mortality were compared. Patients in PTBS group had shorter hospital stay and lower initial and overall expense than the BBS group (P PTBS group was significantly lower than in EBS group (3/55 vs 11/52, P = 0.0343). Late complications in the EBS group did not differ significantly from PTBS group (7/55 vs 9/52, P = 0.6922). The survival curves in the two groups showed no significant difference (P = 0.5294). Conclusions: 3.

  5. Safety and efficacy analysis of ultrasound-guided percutaneous transhepatic biliary drainage treatment of malignant obstructive jaundice

    Directory of Open Access Journals (Sweden)

    Ye Ben-Gong

    2016-08-01

    Full Text Available Objective: To study the clinical effect and prognosis of percutaneous transhepatic biliary drainage (PTBD treatment of patients with malignant obstructive jaundice. Methods: A total of 112 patients with malignant obstructive jaundice treated in our hospital from April 2009 to February 2014 were retrospectively analyzed. All patients were randomly divided into control group (42 cases and observation group (70 cases, control group received drainage of laparotomy and observation group received PTBD intervention. All patients were followed up for 3 to 23 months. Clinical effect, complication and length of stay were observed and counted after two groups received different treatment, and the results were compared and analyzed. Results: After two groups received different treatment, serum AIL, AST, TBIL and DBIL levels significantly decreased than before treatment, but serum AIL, AST, TBIL and DBIL levels of observation group were lower than those of control group. The levels of WBC and NE of both groups were lower than before treatment, but differences in WBC, NE and PT between the two groups were without statistical significance after treatment. Meanwhile, the incidence of adverse reaction and length of stay of observation group were lower than those of control group, and the differences were statistically significant. Conclusion: Interventional treatment of malignant obstructive jaundice can effectively improve the clinical symptoms, lower incidence of adverse reactions and shorten the length of stay, which is the preferred method for medically inoperable malignant obstructive jaundice and worth clinical popularization.

  6. Percutaneous transhepatic portal vein catheterisation in the diagnosis of hormone-producing tumors in the splanchnic area

    International Nuclear Information System (INIS)

    Luska, G.; Zick, R.; Otten, G.; Mitzkat, H.J.; Medizinische Hochschule Hannover; Medizinische Hochschule Hannover

    1981-01-01

    During 1980, percutaneous transhepatic portal vein catheterisation was carried out in eight patients with suspected hormone-producing tumours in an attempt to localise these. Seven patients with hyperinsulinism were suspected of having an insulinoma and one a gastrinoma. There were no complications following the catheterisation, and difficulties were reduced by the use of a special catheter. The blood samples were examined by radio-immunological methods for insulin or gastrin. On the basis of localised rise in hormone level, it was possible to diagnose three insulinomas and one gastrinoma in the pancreas. The betacell tumours were removed by enucleation or segmental resection, the gastrinoma by a Whipple's operation. Three patients showed an insulin gradient and sub-total pancreatectomies were performed. In one patient there was no definite abnormality in the insulin level and an operation has so far not been performed. Our experience indicates that this technique is difficult, but is nevertheless a reliable method for localising hormone-producing tumours and surgery should not be carried out without it. (orig.) [de

  7. Balloon dilatation biopsy of the biliary stricture through the percutaneous transhepatic biliary drainage tract: Feasibility and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Ji Hoon; Ryeom, Hun Kyu; Jang, Yun Jin; Kim, Gab Chul; Cho, Seung Hyun; Song, Jung Hup [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2016-01-15

    To evaluate the feasibility and diagnostic accuracy of the balloon dilatation biopsy for the biliary stricture through the percutaneous transhepatic biliary drainage (PTBD) tract. The study included 35 patients who underwent balloon dilatation biopsy for the biliary stricture through the PTBD tract. Balloon dilatation was done with a balloon catheter of 10-mm or 12-mm diameter. Soft tissue adherent to the retrieved balloon catheter and soft tissue components separated by gauze filtration of evacuated bile were sampled for histopathologic examination. The results were compared with the final diagnosis which was made by clinical and imaging follow-up for mean 989 days (n = 34) and surgery with histopathologic examination (n = 1). Procedure-related complications and diagnostic accuracy were assessed. Tissues suitable for histopathologic examination were obtained in 31 out of 35 patients (88.6%). In 3 patients, self-limiting hemobilia was noted. No major complication was noted. The sensitivity, specificity, diagnostic accuracy, positive and negative predictive values for diagnosis of malignant stricture were 70.0%, 100%, 90.3%, 100%, and 87.5%, respectively. Balloon dilatation biopsy of the biliary stricture through the PTBD tract is a feasible and accurate diagnostic method. It can be a safe alternative to the endoscopic retrograde cholangiography biopsy or forceps biopsy through the PTBD tract.

  8. US-guided percutaneous transhepatic biliary drainage: comparative study of right-sided and left-sided approach

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hwan; Cha, Soon Joo [College of Medicine, Inje Univ., Kimhae (Korea, Republic of)

    2002-02-01

    To compare the feasibility and safety of US-guided right and left percutaneous transhepatic biliary drainage (PTBD). Between March 1998 and May 1999, 32 patients underwent 36 US-guided right or left PTBD in referred order, alternatively. The causes of biliary obstruction were bile duct stone (n=2), bile duct carcinoma (n=10), carcinoma of the pancreas (n=9), GB carcinoma (n=7), metastasis to the porta hepatis (n=3), and carcinoma of the ampulla of vater (n=1). Technical success, procedure time, fluoroscopic time, and complications were evaluated. PTBD was successful in 94% of both right and left approach. The average procedure time was 9.7 {+-}3.8 min. in the right approach and 9.6 {+-}3.1 min. in the left approach, respectively (p=0.794). The average fluoroscopic time were 3.9{+-}2.4 min. in the right approach and 3.8{+-}2.2 min. in the left approach (p=0.892). A major complication, bile peritonitis, occurred in one of 16 patient with right-sided approach. Minor complications occurred in six right (2 hemobilia, 3 tube malfunction, 1 cholangitis) and three left (1 hemobilia, 1 fever, 1cholangitis) PTBD. There were no significant difference in the complication rates between right and left PTBD (p=0.729). There were no significant differences in feasibility and safety in US-guided right and left PTBD.

  9. Percutaneous retrieval of a vena cava filter from the right atrium: case report

    International Nuclear Information System (INIS)

    Rasuli, P.; Mehran, R.; French, G.; Turek, M.; Lalonde, K.A.; Cardinal, P.

    2000-01-01

    Migration of vena cava filters can occur spontaneously, but it can also occur as a result of entanglement of the filter with a guidewire, particularly during 'blind' (unguided) insertion of a central venous line. When a filter migrates to the heart, traditional practice has been either to leave the filter in place or to remove it surgically by means of open heart surgery and cardiopulmonary bypass. We found only 6 reports of successful percutaneous retrieval or repositioning of a vena cava filter (Table 1). We describe a new interventional technique for retrieving a filter from the right atrium and a novel endosurgical method for removing a filter from the innominate vein. (author)

  10. Intracranial hemorrhage due to intracranial hypertension caused by the superior vena cava syndrome

    DEFF Research Database (Denmark)

    Bartek, Jiri; Abedi-Valugerdi, Golbarg; Liska, Jan

    2013-01-01

    We report a patient with intracranial hemorrhage secondary to venous hypertension as a result of a giant aortic pseudoaneurysm that compressed the superior vena cava and caused obstruction of the venous return from the brain. To our knowledge, this is the first patient reported to have...... an intracranial hemorrhage secondary to a superior vena cava syndrome. The condition appears to be caused by a reversible transient rise in intracranial pressure, as a result of compression of the venous return from the brain. Treatment consisted of surgery for the aortic pseudoaneurysm, which led...

  11. Gianturco expandable wire stents for treatment of superior vena cava syndrome secondary to lung carcinoma

    International Nuclear Information System (INIS)

    Rosch, J.; Bedell, J.; Putnam, J.; Antonovic, R.; Uchida, B.

    1986-01-01

    Two patients with superior vena cava syndrome (SVCS) secondary to lung carcinoma which recurred after maximum-dose radiation therapy were treated with placement of modified Gianturco expandable wire stents constructed in the authors' research laboratory. Symptoms of SVCS disappeared in 24 hours after stent placement, and the patients remained asymptomatic to their last follow-up, 2 1/2 months after the procedure (to the submission of this abstract). Both stents were widely patent at that time on superior vena cavograms and draining well the head, neck, and upper extremity circulation to the right atrium

  12. Outcome of prolonged acute vena cava occlusion after iatrogenic transection and repair in a dog.

    Science.gov (United States)

    Halwagi, Marie-Chantal; Crawford, Evan; Hoddinott, Katie; Oblak, Michelle L

    2017-08-01

    A 12-year-old castrated male Airedale terrier dog was diagnosed with a hepatocellular carcinoma in the right medial liver lobe. During tumor resection, inadvertent stapling and transection of the caudal vena cava occurred. Complete caval occlusion was required for 18 minutes and primary anastomosis was completed. The dog received 2 blood transfusions and developed mild pelvic limb edema after surgery. Computed tomography evaluation 9 months after surgery showed collateral circulation and suspected stricture of the vena cava with an absence of clinical effect. The dog remained alive and asymptomatic more than 1 year after surgery.

  13. Anatomy of Inferior Mesenteric Artery in Fetuses

    Directory of Open Access Journals (Sweden)

    Ayesha Nuzhat

    2016-01-01

    Full Text Available Aim. To analyze Inferior Mesenteric Artery in fetuses through its site of origin, length, diameter, and variation of its branches. Method. 100 fetuses were collected from various hospitals in Warangal at Kakatiya Medical College in Andhra Pradesh, India, and were divided into two groups, group I (second-trimester fetuses and group II (third-trimester fetuses, followed by dissection. Result. (1 Site of Origin. In group I fetuses, origin of Inferior Mesenteric Artery was at third lumbar vertebra in 33 out of 34 fetuses (97.2%. In one fetus it was at first lumbar vertebra, 2.8%. In all group II fetuses, origin of Inferior Mesenteric Artery was at third lumbar vertebra. (2 Length. In group I fetuses it ranged between 18 and 30 mm, average being 24 mm except in one fetus where it was 48 mm. In group II fetuses the length ranged from 30 to 34 mm, average being 32 mm. (3 Diameter. In group I fetuses it ranged from 0.5 to 1 mm, and in group II fetuses it ranged from 1 to 2 mm, average being 1.5 mm. (4 Branches. Out of 34 fetuses of group I, 4 fetuses showed variation. In one fetus left colic artery was arising from abdominal aorta, 2.9%. In 3 fetuses, Inferior Mesenteric Artery was giving a branch to left kidney, 8.8%. Out of 66 fetuses in group II, 64 had normal branching. In one fetus left renal artery was arising from Inferior Mesenteric Artery, 1.5%, and in another fetus one accessory renal artery was arising from Inferior Mesenteric Artery and entering the lower pole of left kidney. Conclusion. Formation, course, and branching pattern of an artery depend on development and origin of organs to attain the actual adult position.

  14. Inferior hilar window on lateral chest radiographs

    International Nuclear Information System (INIS)

    Park, C.K.; Webb, W.R.; Klein, J.S.

    1990-01-01

    This paper determines the accuracy of lateral chest radiography in the detection of masses in the inferior hilar window, a normally avascular hilar region anterior to the lower lobe bronchi. Fifty patients with normal thoracic CT scans and 25 with hilar masses/adenopathy were selected retrospectively. The 75 corresponding lateral chest radiographs were blindly evaluated for visibility of the anterior walls of the lower lobe bronchi and the presence and laterality of abnormal soft tissue (>1 cm) in the inferior hilar window. Only a 7 x 7-cm square of the lateral radiograph was viewed

  15. Thrombosis caused by polyurethane double-lumen subclavian superior vena cava catheter and hemodialysis

    DEFF Research Database (Denmark)

    Wanscher, Maria Rørbæk; Frifelt, J J; Smith-Sivertsen, C

    1988-01-01

    During an 18-month period, 82 consecutive patients (37 women and 45 men), with a mean age of 50 yr (range 15 to 74), underwent hemodialysis with 91 polyurethane double-lumen subclavian superior vena cava catheters inserted via the right subclavian vein. Upon catheter removal, venograms were...

  16. An elusive persistent left superior vena cava draining into left atrium

    NARCIS (Netherlands)

    A. Soward; F.J. ten Cate (Folkert); P.M. Fioretti (Paolo); P.W.J.C. Serruys (Patrick); J.R.T.C. Roelandt (Jos)

    1986-01-01

    textabstractA case report of a persistent left superior vena cava draining into left atrium with a fibromuscular left ventricular outflow tract obstruction and a small atrial septal defect. The anomalous vessel escaped detection during two right and left heart catheterizations from the right arm and

  17. Prenatal diagnosis of long QT syndrome with the superior vena cava-aorta Doppler approach.

    Science.gov (United States)

    Chabaneix, Julie; Andelfinger, Gregor; Fournier, Anne; Fouron, Jean-Claude; Raboisson, Marie-Josée

    2012-10-01

    We describe a fetus at 36 weeks with long QT syndrome presenting with variable types of atrioventricular blocks, ventricular premature beats, and torsades de pointes. All these diagnoses were made with the superior vena cava-aorta Doppler approach and confirmed with postnatal electrocardiography. Copyright © 2012 Mosby, Inc. All rights reserved.

  18. The clinical application of the implantation of retrievable filters in superior vena cava

    International Nuclear Information System (INIS)

    Tian Yulong; Zhang Xitong; Hong Duo

    2011-01-01

    Objective: To investigate the safety of the placement of Tulip retrievable filter in superior vena cava and to discuss the prevention of pulmonary embolism (PE). Methods: Implantation of Tulip retrievable filter in superior vena cava was performed in ten patients (6 males and 4 females, aged 42-60 years) with acute or subacute deep venous thrombosis in upper extremity or cephalo-cervical region. After the placement of filter, the local via-catheter thrombolysis was conducted. The clinical results, such as the improvement of venous obstructed symptoms at upper extremity or cephalo-cervical region, were recorded. The filter's shape and location were checked. The possible occurrence of pulmonary embolism was observed. Results: The filter was successfully implanted in supper vena cava in all patients, and the deep venous thrombosis at upper