  1. Cardiac ablation

    Directory of Open Access Journals (Sweden)

    Kelly Ratheal

    2016-01-01

    Full Text Available Cardiac ablation is a procedure that uses either radiofrequency or cryothermal energy to destroy cells in the heart to terminate and/or prevent arrhythmias. The indications for cardiac catheter ablation include refractory, symptomatic arrhythmias, with more specific guidelines for atrial fibrillation in particular. The ablation procedure itself involves mapping the arrhythmia and destruction of the aberrant pathway in an effort to permanently prevent the arrhythmia. There are many types of arrhythmias, and they require individualized approaches to ablation based on their innately different electrical pathways. Ablation of arrhythmias, such as Wolff-Parkinson-White syndrome, AV nodal reentrant tachycardia, and atrial-fibrillation, is discussed in this review. Ablation has a high success rate overall and minimal complication rates, leading to improved quality of life in many patients.

  2. Minimally invasive cardiac surgery and transesophageal echocardiography

    Directory of Open Access Journals (Sweden)

    Ajay Kumar Jha

    2014-01-01

    Full Text Available Improved cosmetic appearance, reduced pain and duration of post-operative stay have intensified the popularity of minimally invasive cardiac surgery (MICS; however, the increased risk of stroke remains a concern. In conventional cardiac surgery, surgeons can visualize and feel the cardiac structures directly, which is not possible with MICS. Transesophageal echocardiography (TEE is essential during MICS in detecting problems that require immediate correction. Comprehensive evaluation of the cardiac structures and function helps in the confirmation of not only the definitive diagnosis, but also the success of surgical treatment. Venous and aortic cannulations are not under the direct vision of the surgeon and appropriate positioning of the cannulae is not possible during MICS without the aid of TEE. Intra-operative TEE helps in the navigation of the guide wire and correct placement of the cannulae and allows real-time assessment of valvular pathologies, ventricular filling, ventricular function, intracardiac air, weaning from cardiopulmonary bypass and adequacy of the surgical procedure. Early detection of perioperative complications by TEE potentially enhances the post-operative outcome of patients managed with MICS.

  3. Transesophageal echocardiography. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Lambertz, Heinz; Lethen, Harald

    2013-01-01

    The book on transesophageal echocardiography covers the following issues: Development of transesophageal echocardiography, technical advances; indications and contraindication for transesophageal echocardiography; systematic of the medical examination process; cardiac valves and valve prostheses; mitral and aortic valvuloplasty, TAVI and interventional treatment of mitral regurgitation; infectious endocarditis; one-way and effluence disturbances of the left and right ventricle; diseases of the thoracic aorta; undefined right ventricle enlargement; lung embolism, acute infarct complications; TEE during anesthesia and perioperative intensive medicine, cardiac sources of embolism; cardiac tumors, mediastinal lymph nodes; pericardiac diseases; congenital heart diseases in childhood and adulthood; catheter interventions and heart valve reconstruction; surgically corrected congenital cardiac defects; intracavitary versus transesophageal echocardiography; three-dimensional TEE; coronary diagnostics; ischemia and vitality diagnostics.

  4. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    Science.gov (United States)

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  5. Feasibility of transesophageal echocardiography in birds without cardiac disease.

    Science.gov (United States)

    Beaufrère, Hugues; Pariaut, Romain; Nevarez, Javier G; Tully, Thomas N

    2010-03-01

    To establish a technique of transesophageal echocardiography (TEE) in birds without cardiac disease and describe the imaging planes obtained. Validation study. 18 birds including 3 pigeons (Columbia livia), 3 barred owls (Strix varia), 2 red-tailed hawks (Buteo jamaicensis), 1 goose (Anser anser), 1 mallard duck (Anas platyrhynchos), 1 Muscovy duck (Cairina moschata), 2 brown pelicans (Pelecanus occidentalis), 2 Hispaniolan Amazon parrots (Amazona ventralis), 2 red-fronted macaws (Ara rubrogenys), and 1 military macaw (Ara militaris). For each bird, anesthesia was induced and maintained by use of isoflurane. A pediatric, multiplane transesophageal ultrasound probe was passed into the esophagus and adjusted to the level of the heart for echocardiography. Probe positions were recorded via fluoroscopy, and associated imaging planes were described. TEE was performed successfully in all birds except the pelicans, 1 Hispaniolan Amazon parrot, and the red-fronted macaws. Five imaging planes of the heart were consistently viewed from 3 positions of the probe (identified as caudal, middle, and cranial positions relative to the cardiac silhouette). M-mode echocardiography of the left ventricle and the aortic root was performed. Color flow and spectral Doppler ultrasonographic images of in- and outflow regions were obtained. One Hispaniolan Amazon parrot died as a result of esophageal perforation. TEE examination of birds was feasible and provided a larger number of imaging planes with better resolution and details than those typically achieved via a transcoelomic approach. However, TEE should be performed with caution in psittacines.

  6. Small, smooth, nonmobile cardiac myxoma detected by transesophageal echocardiography following recurrent cerebral infarction: a case report.

    Science.gov (United States)

    Saito, Yuki; Aizawa, Yoshihiro; Monno, Koyuru; Nagashima, Koichi; Kurokawa, Sayaka; Osaka, Shunji; Akimoto, Takayoshi; Kamei, Satoshi; Tanaka, Masashi; Hirayama, Atsushi

    2017-05-10

    Cardiac myxoma is known to cause repeated events of cerebral embolism. Soft and irregularly shaped myxomas with high mobility are associated with a higher occurrence of cerebral embolism. In contrast, nonmobile cardiac myxomas with a round regular shape are rarely considered to be a cause of cerebral embolism. In this case, we present a patient with recurrent cerebral embolism associated with a small and nonmobile cardiac myxoma of round regular shape. A 76-year-old Japanese man presented to our hospital with weakness in his right upper extremity. He had a history of right frontal lobe infarction in the previous month. T2-weighted magnetic resonance imaging revealed an area of hyperintensity in the left precentral gyrus, indicating acute cerebral infarction. Transthoracic echocardiography revealed normal left ventricular function and no abnormalities. However, transesophageal echocardiography showed a small and nonmobile left atrial tumor with round regular shape attached to the ostium secundum of the atrial septum. Based on these findings, we diagnosed recurrent cerebral infarction due to embolization caused by left atrial myxoma, and cardiac tumor extraction was performed on hospitalization day 36. The excised tumor measured 0.6 × 0.6 × 0.5 cm and was diagnosed as cardiac myxoma by histologic examination. Even small and nonmobile cardiac myxomas with a round regular shape may cause recurrent cerebral infarction. The diagnosis of this type of atrial myxoma is elusive and transesophageal echocardiography was an effective method of detection. In a clinical situation, this type of cardiac myxoma may be overlooked as a cause of cerebral infarction.

  7. Transesophageal echocardiography for cardiac thromboembolic risk assessment in patients with severe, symptomatic aortic valve stenosis referred for potential transcatheter aortic valve implantation.

    Science.gov (United States)

    Lenders, Guy D; Paelinck, Bernard P; Wouters, Kristien; Claeys, Marc J; Rodrigus, Inez E; Van Herck, Paul L; Vrints, Christiaan J; Bosmans, Johan M

    2013-05-15

    Stroke is a devastating complication after transcatheter aortic valve implantation (TAVI) and might partially be related to cardiac embolization. The aim of this single-center prospective study was to determine the incidence of intracardiac thrombi and left atrial spontaneous echo contrast (SEC), both known predictors of cardiac embolic stroke, in patients referred for potential TAVI. One hundred four consecutive patients with severe symptomatic aortic valve stenosis and at high or very high risk for surgery were included and underwent transesophageal echocardiography. In 11 patients (10.6%), intracardiac thrombi were detected, and 25 patients (24%) showed dense grade 2 SEC. Atrial fibrillation (p risk patients with severe aortic valve stenosis referred for potential TAVI is high and can accurately be detected using transesophageal echocardiography. Systematic thromboembolic evaluation using transesophageal echocardiography is thus recommended in patients referred for TAVI. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Transesophageal echocardiography. 3. rev. and enl. ed.; Transoesophageale Echokardiografie. Lehrbuch und Altlas zur Untersuchungstechnik und Befundinterpretation

    Energy Technology Data Exchange (ETDEWEB)

    Lambertz, Heinz [ECHOECUCT-Akademie, Wiesbaden (Germany); Lethen, Harald (eds.) [Internistische Intensivmedizin, Wiesbaden (Germany). Innere Medizin/Kardiologie

    2013-02-01

    The book on transesophageal echocardiography covers the following issues: Development of transesophageal echocardiography, technical advances; indications and contraindication for transesophageal echocardiography; systematic of the medical examination process; cardiac valves and valve prostheses; mitral and aortic valvuloplasty, TAVI and interventional treatment of mitral regurgitation; infectious endocarditis; one-way and effluence disturbances of the left and right ventricle; diseases of the thoracic aorta; undefined right ventricle enlargement; lung embolism, acute infarct complications; TEE during anesthesia and perioperative intensive medicine, cardiac sources of embolism; cardiac tumors, mediastinal lymph nodes; pericardiac diseases; congenital heart diseases in childhood and adulthood; catheter interventions and heart valve reconstruction; surgically corrected congenital cardiac defects; intracavitary versus transesophageal echocardiography; three-dimensional TEE; coronary diagnostics; ischemia and vitality diagnostics.

  9. Complications of Intraoperative Transesophageal Echocardiography in Adult Cardiac Surgical Patients—Experience of Two Institutions in Taiwan

    Directory of Open Access Journals (Sweden)

    Chi-Hsiang Huang

    2007-01-01

    Full Text Available There is some safety concern about transesophageal echocardiography (TEE when it is used routinely during cardiac operations. The purpose of this investigation was to study the incidence of intraoperative TEE-associated complications in adult cardiac surgical patients. The study population comprised 6255 consecutive adult cardiac surgical patients with intraoperative TEE examinations. TEE-associated complications occurred in 25 patients (0.4%. Most of these complications consisted of oropharyngeal mucosal bleeding (15/25, 60%. Esophageal perforation occurred in one patient. Two patients experienced upper gastrointestinal bleeding. Seven patients experienced dental injuries, and TEE probe insertion failed in 10 patients. We conclude that intraoperative TEE-associated complications in cardiac operations is very low; the complication rate we found was comparable to previously reported values. [J Formos Med Assoc 2007; 106(1:92-95

  10. Transesophageal echocardiography as an alternative for the assessment of the trauma and critical care patient.

    Science.gov (United States)

    Rose, David D

    2003-06-01

    Transesophageal echocardiography was first described and used to monitor cardiac function in 1976. Initially adopted by cardiac anesthesiologists and cardiologists, it has gained acceptance as an important diagnostic tool in the monitoring and assessment of cardiac status in the critically ill and trauma patient population. Comparative data suggest that transesophageal echocardiography provides rapid real-time noninvasive monitoring of the critically ill and avoids the morbidity and mortality that is associated with more invasive methods of patient monitoring. In addition, transesophageal echocardiography affords the practitioner reliable cardiac filling volumes based on direct left ventricular assessment compared to pressure data that are based on indirect right ventricular and pulmonary occlusive pressures. In a healthcare environment that seeks optimum patient assessment while requiring an approach that encourages cost-effective, noninvasive, and minimal patient risk, those nurse anesthetists who work in institutions that have transesophageal echocardiographic capabilities should learn this newer technology and begin to incorporate it into their practice.

  11. Anatomic characterization of cavotricuspid isthmus by 3D transesophageal echocardiography in patients undergoing radiofrequency ablation of typical atrial flutter.

    Science.gov (United States)

    Regoli, François; Faletra, Francesco; Marcon, Serena; Leo, Laura Anna; Dequarti, Maria Cristina; Caputo, Maria Luce; Conte, Giulio; Moccetti, Tiziano; Auricchio, Angelo

    2018-01-01

    Radiofrequency ablation (RFA) is the treatment of choice of cavotricuspid isthmus (CTI)-dependent atrial flutter. Procedural time is highly variable due to anatomical structures. This study aimed to characterize CTI anatomy by transesophageal 3D echocardiography imaging (3D-TEE) to identify anatomic structures related to longer ablation time. Thirty-one consecutive patients (mean age 67.3 ± 11.5 years, 22 males) underwent CTI-ablation procedure. Before ablation, TEE was performed and 3D-TEE images were acquired to evaluate CTI anatomy qualitatively as well as perform measures of CTI morphological features. The electrophysiologist performing RFA was blinded to 3D-TEE data. Bidirectional block of CTI was achieved in all patients without procedural complications after a median ablation time of 11 (IQR 7-14) min. Patients with RFA time ≥11 min (Group 2) presented lower left ventricular ejection fraction (51.1 ± 17.0 vs. 59.5 ± 6.6%, P 3D-TEE imaging is extremely helpful in qualitative and quantitative evaluation of CTI anatomy in patients undergoing RFA for symptomatic typical atrial flutter. Detection of a deep right atrial pouch was found to be associated with significantly prolonged CTI ablation time to achieve bidirectional block. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  12. Transesophageal echocardiography in NeoChord procedure

    Directory of Open Access Journals (Sweden)

    Pittarello Demetrio

    2015-01-01

    Full Text Available Background: Transapical off-pump mitral valve intervention with neochord implantation for degenerative mitral valve disease have been recently introduced in the surgical practice. The procedure is performed under 2D-3D transesophageal echocardiography guidance. Methods: The use of 3D real-time transesophageal echocardiography provides more accurate information than 2D echocardiography only in all the steps of the procedure. In particular 3D echocardiography is mandatory for preoperative assessment of the morphology of the valve, for correct positioning of the neochord on the diseased segment , for the final tensioning of the chordae and for the final evaluation of the surgical result. Result and Conclusion: This article is to outline the technical aspects of the transesophageal echocardiography guidance of the NeoChord procedure showing that the procedure can be performed only with a close and continuous interaction between the anesthesiologist and the cardiac surgeon.

  13. [Catheter ablation in patients with refractory cardiac arrhythmias with radiofrequency techniques].

    Science.gov (United States)

    de Paola, A A; Balbão, C E; Silva Netto, O; Mendonça, A; Villacorta, H; Vattimo, A C; Souza, I A; Guiguer Júnior, N; Portugal, O P; Martinez Filho, E E

    1993-02-01

    evaluate the efficacy of radiofrequency catheter ablation in patients with refractory cardiac arrhythmias. twenty patients with refractory cardiac arrhythmias were undertaken to electrophysiologic studies for diagnosis and radiofrequency catheter ablation of their reentrant arrhythmias. Ten patients were men and 10 women with ages varying from 13 to 76 years (mean = 42.4 years). Nineteen patients had supraventricular tachyarrhythmias: One patient had atrial tachycardia and 1 atrial fibrillation with rapid ventricular rate, 5 patients had reentrant nodal tachycardia, 12 patients had reentrant atrioventricular tachycardia and 1 patient had right ventricular outflow tract tachycardia. the mean time of the procedure was 4.1 hours. The radiofrequency current energy applied was 40-50 V for 30-40 seconds. Ablation was successful in 18/20 (90%) patients; in 15/18 (83%) of successfully treated patients the same study was done for diagnosis and radiofrequency ablation. One patient had femoral arterial occlusion and was treated with no significant sequelae. During a mean follow-up of 4 months no preexcitation or reentrant tachycardia occurred. the results of our experience with radiofrequency catheter ablation of cardiac arrhythmias suggest that this technique can benefit an important number of patients with cardiac arrhythmias.

  14. Real-time three dimensional transesophageal echocardiography: technical aspects and clinical applications

    Directory of Open Access Journals (Sweden)

    Sergio Mondillo

    2010-02-01

    Full Text Available Real-time three-dimensional transeso-phageal echocardiography (RT3DTEE is now commonly used in daily clinical practice. The transesophageal, compared to the transthoracic approach, allows the visualization of the whole spectrum of the mitral valve apparatus and the posterior cardiac structures. Moreover, images obtained by RT 3D TEE provide a unique and complete visualization of the mitral valve prosthetic elements. Indeed, the possibility to visualize guidewires and catheters in cardiac chambers and their relationship with cardiac structures during percutaneous transcatheter procedures reduces the time of radiation exposure and simplifies the approach becoming the reference method for monitoring. This review aims to underline the potential clinical applications and the advantages of RT3DTEE compared to other methods.

  15. Survival and sudden cardiac death after septal ablation for hypertrophic obstructive cardiomyopathy

    DEFF Research Database (Denmark)

    Jensen, Morten Kvistholm; Havndrup, Ole; Hassager, Christian

    2011-01-01

    Reports of long-term survival and the risk of sudden cardiac death (SCD) after percutaneous transluminal septal myocardial ablation (PTSMA) in patients with hypertrophic obstructive cardiomyopathy (HOCM) are sparse.......Reports of long-term survival and the risk of sudden cardiac death (SCD) after percutaneous transluminal septal myocardial ablation (PTSMA) in patients with hypertrophic obstructive cardiomyopathy (HOCM) are sparse....

  16. Cardiac impairment evaluated by transesophageal echocardiography and invasive measurements in rats undergoing sinoaortic denervation.

    Directory of Open Access Journals (Sweden)

    Raquel A Sirvente

    Full Text Available BACKGROUND: Sympathetic hyperactivity may be related to left ventricular (LV dysfunction and baro- and chemoreflex impairment in hypertension. However, cardiac function, regarding the association of hypertension and baroreflex dysfunction, has not been previously evaluated by transesophageal echocardiography (TEE using intracardiac echocardiographic catheter. METHODS AND RESULTS: We evaluated exercise tests, baroreflex sensitivity and cardiovascular autonomic control, cardiac function, and biventricular invasive pressures in rats 10 weeks after sinoaortic denervation (SAD. The rats (n = 32 were divided into 4 groups: 16 Wistar (W with (n = 8 or without SAD (n = 8 and 16 spontaneously hypertensive rats (SHR with (n = 8 or without SAD (SHRSAD (n = 8. Blood pressure (BP and heart rate (HR did not change between the groups with or without SAD; however, compared to W, SHR groups had higher BP levels and BP variability was increased. Exercise testing showed that SHR had better functional capacity compared to SAD and SHRSAD. Echocardiography showed left ventricular (LV concentric hypertrophy; segmental systolic and diastolic biventricular dysfunction; indirect signals of pulmonary arterial hypertension, mostly evident in SHRSAD. The end-diastolic right ventricular (RV pressure increased in all groups compared to W, and the end-diastolic LV pressure increased in SHR and SHRSAD groups compared to W, and in SHRSAD compared to SAD. CONCLUSIONS: Our results suggest that baroreflex dysfunction impairs cardiac function, and increases pulmonary artery pressure, supporting a role for baroreflex dysfunction in the pathogenesis of hypertensive cardiac disease. Moreover, TEE is a useful and feasible noninvasive technique that allows the assessment of cardiac function, particularly RV indices in this model of cardiac disease.

  17. Early detection and efficient therapy of cardiac angiosarcoma due to routine transesophageal echocardiography after cerebrovascular stroke

    Directory of Open Access Journals (Sweden)

    Dirk Vogelgesang

    2008-08-01

    Full Text Available Dirk Vogelgesang1, Johannes B Dahm2, Holm Großmann3, Andre Hippe4, Astrid Hummel5, Christian Lotze6, Silke Vogelgesang71Practice of Cardiology, Greifswald, 2Practice of Cardiology, Goettingen, 3Department of Cardiovascular Surgery, Herzzentrum Karlsburg, 4Department of Neurology, 5Department of Cardiology, 6Department of Haematology and Oncology, 7Department of Pathology, University of Greifswald, Greifswald, GermanyAbstract: Primary malignant cardiac tumors (cardiac angiosarcomas are exceedingly rare. Since there are initially nonspecific or missing symptoms, these tumors are usually diagnosed only in an advanced, often incurable stage, after the large tumor mass elicits hemodynamic obstructive symptoms. A 59-year-old female presented with symptoms of cerebral ischemia. A computed tomography (CT scan showed changes suggestive of stroke. Transesophageal echocardiography revealed an inhomogeneous, medium-echogenic, floating mass at the roof of the left atrium near the mouth of the right upper pulmonary vein, indicative of a thrombus. At surgery, a solitary tumor was completely enucleated. Histologically, cardiac angiosarcoma was diagnosed. The patient received adjuvant chemotherapy and was free of symptoms and recurrence of disease at 14 months follow-up. Due to the fortuitous appearance of clinical signs indicative of stroke, cardiac angiosarcoma was diagnosed and effectively treated at an early, nonmetastatic, and therefore potentially curable stage. Although cardiac angiosarcoma is a rare disease, it should be taken into consideration as a potential cause of cerebral embolic disease.Keywords: cardiac angiosarcoma, stroke, embolism

  18. Myocardial function during transesophageal cardiac pacing in patients with coronary heart diseases when selected for surgical management: nuclear stethoscopic findings

    International Nuclear Information System (INIS)

    Fitilev, S.B.; Mironova, M.A.; Gordeev, V.F.; Satrapinskij, V.Yu.; Badalyan, E.A.; Akademiya Meditsinskikh Nauk SSSR, Moscow

    1991-01-01

    Studies of myocardial function during transesophageal cardiac pacing (TECP) were carried out in 70 patients with coronary heart diseases (CHD). All the patients were examined for central and intracardiac hemodynamics during TECP using nuclear stetoscope Bios (USA). The obtained data of central hemodynamics and myocardium contractibility make it possible to judge not only of pathological hemodynamics changes, as a CHD diagnostic factor, but of factors limiting reserve of cardiovascular system as well, depending on morphological heart changes

  19. Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions.

    Science.gov (United States)

    Perk, Gila; Lang, Roberto M; Garcia-Fernandez, Miguel Angel; Lodato, Joe; Sugeng, Lissa; Lopez, John; Knight, Brad P; Messika-Zeitoun, David; Shah, Sanjiv; Slater, James; Brochet, Eric; Varkey, Mathew; Hijazi, Ziyad; Marino, Nino; Ruiz, Carlos; Kronzon, Itzhak

    2009-08-01

    Real-time three-dimensional (RT3D) echocardiography is a recently developed technique that is being increasingly used in echocardiography laboratories. Over the past several years, improvements in transducer technologies have allowed development of a full matrix-array transducer that allows acquisition of pyramidal-shaped data sets. These data sets can be processed online and offline to allow accurate evaluation of cardiac structures, volumes, and mass. More recently, a transesophageal transducer with RT3D capabilities has been developed. This allows acquisition of high-quality RT3D images on transesophageal echocardiography (TEE). Percutaneous catheter-based procedures have gained growing acceptance in the cardiac procedural armamentarium. Advances in technology and technical skills allow increasingly complex procedures to be performed using a catheter-based approach, thus obviating the need for open-heart surgery. The authors used RT3D TEE to guide 72 catheter-based cardiac interventions. The procedures included the occlusion of atrial septal defects or patent foramen ovales (n=25), percutaneous mitral valve repair (e-valve clipping; n=3), mitral balloon valvuloplasty for mitral stenosis (n=10), left atrial appendage obliteration (n=11), left atrial or pulmonary vein ablation for atrial fibrillation (n=5), percutaneous closures of prosthetic valve dehiscence (n=10), percutaneous aortic valve replacement (n=6), and percutaneous closures of ventricular septal defects (n=2). In this review, the authors describe their experience with this technique, the added value over multiplanar two-dimensional TEE, and the pitfalls that were encountered. The main advantages found for the use RT3D TEE during catheter-based interventions were (1) the ability to visualize the entire lengths of intracardiac catheters, including the tips of all catheters and the balloons or devices they carry, along with a clear depiction of their positions in relation to other cardiac structures, and

  20. Real time assessment of RF cardiac tissue ablation with optical spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Demos, S G; Sharareh, S

    2008-03-20

    An optical spectroscopy approach is demonstrated allowing for critical parameters during RF ablation of cardiac tissue to be evaluated in real time. The method is based on incorporating in a typical ablation catheter transmitting and receiving fibers that terminate at the tip of the catheter. By analyzing the spectral characteristics of the NIR diffusely reflected light, information is obtained on such parameters as, catheter-tissue proximity, lesion formation, depth of penetration of the lesion, formation of char during the ablation, formation of coagulum around the ablation site, differentiation of ablated from healthy tissue, and recognition of micro-bubble formation in the tissue.

  1. Transesophageal echocardiographic strain imaging predicts aortic biomechanics: Beyond diameter.

    Science.gov (United States)

    Emmott, Alexander; Alzahrani, Haitham; Alreishidan, Mohammed; Therrien, Judith; Leask, Richard L; Lachapelle, Kevin

    2018-03-11

    Clinical guidelines recommend resection of ascending aortic aneurysms at diameters 5.5 cm or greater to prevent rupture or dissection. However, approximately 40% of all ascending aortic dissections occur below this threshold. We propose new transesophageal echocardiography strain-imaging moduli coupled with blood pressure measurements to predict aortic dysfunction below the surgical threshold. A total of 21 patients undergoing aortic resection were recruited to participate in this study. Transesophageal echocardiography imaging of the aortic short-axis and invasive radial blood pressure traces were taken for 3 cardiac cycles. By using EchoPAC (GE Healthcare, Madison, Wis) and postprocessing in MATLAB (MathWorks, Natick, Mass), circumferential stretch profiles were generated and combined with the blood pressure traces. From these data, 2 in vivo stiffness moduli were calculated: the Cardiac Cycle Pressure Modulus and Cardiac Cycle Stress Modulus. From the resected aortic ring, testing squares were isolated for ex vivo mechanical analysis and histopathology. Each square underwent equibiaxial tensile testing to generate stress-stretch profiles for each patient. Two ex vivo indices were calculated from these profiles (energy loss and incremental stiffness) for comparison with the Cardiac Cycle Pressure Modulus and Cardiac Cycle Stress Modulus. The echo-derived stiffness moduli demonstrate positive significant covariance with ex vivo tensile biomechanical indices: energy loss (vs Cardiac Cycle Pressure Modulus: R 2  = 0.5873, P biomechanics and histopathology, which demonstrates the added benefit of using simple echocardiography-derived biomechanics to stratify patient populations. Copyright © 2018. Published by Elsevier Inc.

  2. TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN PATIENTS WITH CEREBRAL ISCHEMIA

    Directory of Open Access Journals (Sweden)

    Kavian Ghandehari

    2010-12-01

    Full Text Available Abstract INTRODUCTION: Transesophageal echocardiography (TEE is superior to Transthoracic echocardiography (TTE in detection of atrial septal defects and aneurysm, aortic atheroma, left atrial thrombus and mitral valve abnormalities. TEE is indicated in young adults with cryptogenic ischemic stroke who are suspected of having cardioembolic mechanism despite non-diagnostic TTE. METHODS: A prospective clinical study was conducted in patients with ischemic stroke or TIA who had TTE done in Ghaem hospital, Mashhad during 2006-2007. Ischemic cerebrovascular events were detected by stroke neurologist. TEE was performed with VIPI3/GE device, USA and a 7 MHz transesophageal probe by an echocardiologist. Patients who did not have TTE before TEE were excluded. Comparison of TEE to TTE results was performed by the echocardiologist and stroke neurologist in each patient. Influence of TEE on therapeutic decisions in each patient was evaluated. RESULTS: Forty-seven patients (20 females, 27 males with a mean age of 42.6±7.3 years were studied. Cardiac and aortic abnormalities were detected in TEE of 35 cases (35/47; 74% with ischemic cerebrovascular events. Cardiac abnormalities of 17 cases (36% were only detectable by TEE. These seventeen cases included 7 patients with PFO, 1 case with ASD, 6 cases with aortic atheroma and 2 patients with clot in the left atrium. Comparing the preventive stroke strategies before and after TEE revealed that it was changed only in two cases (2/47; 4.3% due to performing TEE. These included one patient with a small high-risk PFO and another case with dehicense of mechanical mitral valve. CONCLUSION: TEE revealed cardiac or aortic abnormalities in one-third of the patients with cerebral ischemia and has not been detected by TEE previously. The influence of TEE in therapeutic decisions of patients with ischemic cerebrovascular events is very low.         Keywords: Transesophageal echocardiography, Stroke, Transient Ischemic

  3. Incremental value of live/real time three-dimensional transesophageal echocardiography over the two-dimensional technique in the assessment of primary cardiac malignant fibrous histiocytoma.

    Science.gov (United States)

    Gok, Gulay; Elsayed, Mahmoud; Thind, Munveer; Uygur, Begum; Abtahi, Firoozeh; Chahwala, Jugal R; Yıldırımtürk, Özlem; Kayacıoğlu, İlyas; Pehlivanoğlu, Seçkin; Nanda, Navin C

    2015-07-01

    We describe a case of primary cardiac malignant fibrous histiocytoma where live/real time three-dimensional transesophageal echocardiography added incremental value to the two-dimensional modalities. Specifically, the three-dimensional technique allowed us to delineate the true extent and infiltration of the tumor, to identify characteristics of the tumor mass suggestive of its malignant nature, and to quantitatively assess the total tumor burden. © 2015, Wiley Periodicals, Inc.

  4. Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report.

    Science.gov (United States)

    Nakahira, Junko; Ishii, Hisanari; Sawai, Toshiyuki; Minami, Toshiaki

    2015-03-07

    Fibrin glue is used commonly during cardiac surgery but can behave as an intracardiac abnormal foreign body following surgery. There have been few such cases reported, and they were typically noticed only because of the resulting catastrophic cardiac conditions, such as valvular malfunction. We report a case where, for the first time, transesophageal echocardiography was used to detected fibrin glue that was adherent to the ventricular side of a patient's aortic valve immediately after aortic declamping. A 45-year-old Japanese man with Marfan syndrome underwent an aortic valve-sparing operation to treat moderate aortic valve regurgitation resulting from enlargement of his right coronary cusp. Fibrin glue was lightly applied to the suture line between the previous and new grafts. Transesophageal echocardiography performed prior to weaning from the cardiopulmonary bypass revealed mild aortic valve regurgitation in addition to a mobile membranous structure attached to the ventricular side of his aortic valve. It was identified as fibrin glue. We resolved the regurgitation by removing the fibrin glue and repeating the aortic cusp plication. The patient had no complications during recovery. Fibrin glue can act as an intracardiac foreign body and lead to a potentially fatal embolism. We demonstrated the use of transesophageal echocardiography to detect a fibrin glue-derived intracardiac abnormal foreign body and to confirm its removal. To the best of our knowledge, this is the first case where fibrin glue adherent to the aortic valve was detected by transesophageal echocardiography. These findings demonstrate the importance of using transesophageal echocardiography during cardiac surgery that involves using biological glues.

  5. Transesophageal Echocardiographically-Confirmed Pulmonary Vein Thrombosis in Association with Posterior Circulation Infarction.

    LENUS (Irish Health Repository)

    Kinsella, Justin A

    2010-01-01

    Pulmonary venous thromboembolism has only been identified as a cause of stroke with pulmonary arteriovenous malformations\\/fistulae, pulmonary neoplasia, transplantation or lobectomy, and following percutaneous radiofrequency ablation of pulmonary vein ostia in patients with atrial fibrillation. A 59-year-old man presented with a posterior circulation ischemic stroke. \\'Unheralded\\' pulmonary vein thrombosis was identified on transesophageal echocardiography as the likely etiology. He had no further cerebrovascular events after intensifying antithrombotic therapy. Twenty-eight months after initial presentation, he was diagnosed with metastatic pancreatic adenocarcinoma and died 3 months later. This report illustrates the importance of doing transesophageal echocardiography in presumed \\'cardioembolic\\' stroke, and that potential \\'pulmonary venous thromboembolic\\' stroke may occur in patients without traditional risk factors for venous thromboembolism. Consideration should be given to screening such patients for occult malignancy.

  6. Atlas-based mosaicing of 3D transesophageal echocardiography images of the left atrium

    NARCIS (Netherlands)

    Mulder, H.W. (Harriët); Pluim, J.P.W.; Ren, B. (Ben); Haak, A. (Alexander); Viergever, M.A. (Max); Bosch, J.G. (Johan); Stralen, van M. (Marijn)

    2015-01-01

    3D transesophageal echocardiography (TEE) is routinely used for planning and guidance of cardiac interventions. However, the limited field-of-view dictates the compounding of multiple images for visualization of large structures, e.g. the left atrium (LA). Previously, we developed a TEE image

  7. Radiofrequency and microwave tumor ablation in patients with implanted cardiac devices: Is it safe?

    Energy Technology Data Exchange (ETDEWEB)

    Skonieczki, Brendan D., E-mail: bskonieczki@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States); Wells, Catherine, E-mail: cwells1@bidmc.harvard.edu [Department of Radiology, Harvard Medical School/Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Wasser, Elliot J., E-mail: ewasser@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States); Dupuy, Damian E., E-mail: ddupuy@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States)

    2011-09-15

    Purpose: To identify malfunction of implanted cardiac devices during or after thermal ablation of tumors in lung, kidney, liver or bone, using radiofrequency (RF) or microwave (MW) energy. Materials and methods: After providing written consent, 19 patients (15 men and 4 women; mean age 78 years) with pacemakers or pacemaker/defibrillators underwent 22 CT image-guided percutaneous RF or MW ablation of a variety of tumors. Before and after each procedure, cardiac devices were interrogated and reprogrammed by a trained cardiac electrophysiology fellow. Possible pacer malfunctions included abnormalities on electrocardiographic (EKG) monitoring and alterations in device settings. Our institutional review board approved this Health Insurance Portability and Accountability Act-compliant study. Informed consent for participation in this retrospective study was deemed unnecessary by our review board. Results: During 20 of 22 sessions, no abnormalities were identified in continuous, EKG tracings or pacemaker functions. However, in two sessions significant changes, occurred in pacemaker parameters: inhibition of pacing during RF application in one, session and resetting of mode by RF energy in another session. These changes did not, result in hemodynamic instability of either patient. MW ablation was not associated with, any malfunction. In all 22 sessions, pacemakers were undamaged and successfully reset to original parameters. Conclusion: RF or MW ablation of tumors in liver, kidney, bone and lung can be performed safely in patients with permanent intra-cardiac devices, but careful planning between radiology and cardiology is essential to avoid adverse outcomes.

  8. Hemorrhagic Cardiac Tamponade: Rare Complication of Radiofrequency Ablation of Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Loh, Kok Beng; Bux, Shaik Ismail; Abdullah, Basri Johan Jeet; Mokhtar, Raja Amin Raja; Mohamed, Rosmawati [Faculty of Medicine, University of Malaya, Kuala Lumpur (Malaysia)

    2012-09-15

    Local treatment for hepatocellular carcinoma (HCC) has been widely used in clinical practice due to its minimal invasiveness and high rate of cure. Percutaneous radiofrequency ablation (RFA) is widely used because its treatment effectiveness. However, some serious complications can arise from percutaneous RFA. We present here a rare case of hemorrhagic cardiac tamponade secondary to an anterior cardiac vein (right marginal vein) injury during RFA for treatment of HCC.

  9. UCP3 Ablation Exacerbates High-Salt Induced Cardiac Hypertrophy and Cardiac Dysfunction

    Directory of Open Access Journals (Sweden)

    Hongmei Lang

    2018-04-01

    Full Text Available Background/Aims: Excessive salt intake and left ventricular hypertrophy (LVH are both critical for the development of hypertension and heart failure. The uncoupling protein 3 (UCP3 plays a cardio-protective role in early heart failure development. However, the potential role for UCP3 in salt intake and LVH is unclear. Methods: UCP3-/- and C57BL/6 mice were placed on either a normal-salt (NS, 0.5% or a high-salt (HS, 8% diet for 24 weeks. The cardiac function, endurance capacity, energy expenditure, and mitochondrial functional capacity were measured in each group. Results: Elevated blood pressure was only observed in HS-fed UCP3-/- mice. High salt induced cardiac hypertrophy and dysfunction were observed in both C57BL/6 and UCP3-/- mice. However, the cardiac lesions were more profound in HS-fed UCP3-/- mice. Furthermore, HS-fed UCP3-/-mice experienced more severe mitochondrial respiratory dysfunction compared with HS-fed C57BL/6 mice, represented by the decreased volume of oxygen consumption and heat production at the whole-body level. Conclusion: UCP3 protein was involved in the incidence of high-salt induced hypertension and the progression of cardiac dysfunction in the early stages of heart failure. UCP3 ablation exacerbated high-salt-induced cardiac hypertrophy and cardiac dysfunction.

  10. Radiofrequency catheter ablation in the treatment of cardiac arrhythmias (first of two parts)

    International Nuclear Information System (INIS)

    Kou, W.H; Morady, F.

    1997-01-01

    The intravenous radiofrequency catheter inside cardiac s chambers, for inspect signals intracardiac s and to encourage, has been developed as diagnostic tool with the purpose to search arrhythmias physiology and physiopathology.Many energy sources has been used: direct energy, radiofrequency 11-15, laser 6,17, and microwave 18,19. A comparison between radiofrequency and electric energy shock has been described in cardiac arrhythmias treatment, in the present article. It has been tested the radiation biological effects and risk in Wolff Parkinson White patients as well as doctors who handling the fluoroscopy for image during the radiofrequency ablation. Has been described the following techniques: Catheter ablation radiofrequency slow way and fast way

  11. The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources.

    Science.gov (United States)

    Mou, Ling; Gong, Quan; Wei, Wei; Gao, Bo

    2013-06-01

    The photoplethysmography (PPG) signals detected by transesophageal oximetry sensor toward aorta arch (AA), descending aorta (DA), and left ventricle (LV) under the guidance of transesophageal echocardiography (TEE) were investigated, and the effects of filter application on PPG signals were evaluated. Eleven cardiac surgical patients were involved. After anesthesia was induced, the TEE probe with a modified pulse oximetry sensor was inserted. Under the guidance of TEE, the AA PPG, DA PPG and LV PPG were detected respectively when ventilator was on and off. The mean alternating current (AC) amplitudes and direct current (DC) values of original and filtered PPG signals were measured. The ratio of AC and DC value (AC/DC) and ventilation-induced AC variations were calculated. Satisfactory PPG waveforms were obtained in all patients under the guidance of TEE. The AC amplitude in LV PPG was significant larger than in AA and DA PPG, and both AC/DC and ventilation-induced AC variation in LV PPG were significantly higher than in AA PPG or DA PPG either. There were no significant differences of AC amplitude between filtered and ventilation off PPG signals. The AC amplitudes and AC/DC toward LV are significantly higher than transesophageal oximeter toward AA or DA, and the effect of mechanical ventilation on transesophageal PPG can be obviously reduced by filtering techniques.

  12. Intra-cardiac echocardiography guided catheter ablation of a right posterior accessory pathway in a patient with Ebstein׳s anomaly

    Directory of Open Access Journals (Sweden)

    Akira Shimane, MD

    2014-12-01

    Full Text Available We report a case of Ebstein׳s anomaly in which radiofrequency catheter ablation of an accessory pathway was successfully performed under intra-cardiac echocardiography. A 50-year-old woman was referred to our hospital for radiofrequency catheter ablation of a paroxysmal supraventricular tachycardia. A 12-lead surface electrocardiogram revealed ventricular pre-excitation associated with type B Wolff–Parkinson–White syndrome. In the baseline electrophysiological study, an orthodromic atrioventricular reciprocating tachycardia with a right posterior accessory pathway was induced. A phased-array intra-cardiac echo probe was positioned in the right atrium to visualize the atrioventricular junction. The key structures for catheter ablation, such as the atrialized right ventricle, atrioventricular junction, and tricuspid valve, were clearly visualized on intra-cardiac echocardiography. Radiofrequency current was successfully delivered at the atrioventricular junction, where a Kent potential was recorded. During a 6-month follow-up period, the patient was free from arrhythmias. The findings in this case suggest that phased-array intra-cardiac echocardiography is useful for ablation of right-sided accessory pathways in patients with Ebstein׳s anomaly.

  13. Effect of Twisted Fiber Anisotropy in Cardiac Tissue on Ablation with Pulsed Electric Fields.

    Directory of Open Access Journals (Sweden)

    Fei Xie

    Full Text Available Ablation of cardiac tissue with pulsed electric fields is a promising alternative to current thermal ablation methods, and it critically depends on the electric field distribution in the heart.We developed a model that incorporates the twisted anisotropy of cardiac tissue and computed the electric field distribution in the tissue. We also performed experiments in rabbit ventricles to validate our model. We find that the model agrees well with the experimentally determined ablation volume if we assume that all tissue that is exposed to a field greater than 3 kV/cm is ablated. In our numerical analysis, we considered how tissue thickness, degree of anisotropy, and electrode configuration affect the geometry of the ablated volume. We considered two electrode configurations: two parallel needles inserted into the myocardium ("penetrating needles" configuration and one circular electrode each on epi- and endocardium, opposing each other ("epi-endo" configuration.For thick tissues (10 mm and moderate anisotropy ratio (a = 2, we find that the geometry of the ablated volume is almost unaffected by twisted anisotropy, i.e. it is approximately translationally symmetric from epi- to endocardium, for both electrode configurations. Higher anisotropy ratio (a = 10 leads to substantial variation in ablation width across the wall; these variations were more pronounced for the penetrating needle configuration than for the epi-endo configuration. For thinner tissues (4 mm, typical for human atria and higher anisotropy ratio (a = 10, the epi-endo configuration yielded approximately translationally symmetric ablation volumes, while the penetrating electrodes configuration was much more sensitive to fiber twist.These results suggest that the epi-endo configuration will be reliable for ablation of atrial fibrillation, independently of fiber orientation, while the penetrating electrode configuration may experience problems when the fiber orientation is not consistent

  14. Effect of Twisted Fiber Anisotropy in Cardiac Tissue on Ablation with Pulsed Electric Fields.

    Science.gov (United States)

    Xie, Fei; Zemlin, Christian W

    2016-01-01

    Ablation of cardiac tissue with pulsed electric fields is a promising alternative to current thermal ablation methods, and it critically depends on the electric field distribution in the heart. We developed a model that incorporates the twisted anisotropy of cardiac tissue and computed the electric field distribution in the tissue. We also performed experiments in rabbit ventricles to validate our model. We find that the model agrees well with the experimentally determined ablation volume if we assume that all tissue that is exposed to a field greater than 3 kV/cm is ablated. In our numerical analysis, we considered how tissue thickness, degree of anisotropy, and electrode configuration affect the geometry of the ablated volume. We considered two electrode configurations: two parallel needles inserted into the myocardium ("penetrating needles" configuration) and one circular electrode each on epi- and endocardium, opposing each other ("epi-endo" configuration). For thick tissues (10 mm) and moderate anisotropy ratio (a = 2), we find that the geometry of the ablated volume is almost unaffected by twisted anisotropy, i.e. it is approximately translationally symmetric from epi- to endocardium, for both electrode configurations. Higher anisotropy ratio (a = 10) leads to substantial variation in ablation width across the wall; these variations were more pronounced for the penetrating needle configuration than for the epi-endo configuration. For thinner tissues (4 mm, typical for human atria) and higher anisotropy ratio (a = 10), the epi-endo configuration yielded approximately translationally symmetric ablation volumes, while the penetrating electrodes configuration was much more sensitive to fiber twist. These results suggest that the epi-endo configuration will be reliable for ablation of atrial fibrillation, independently of fiber orientation, while the penetrating electrode configuration may experience problems when the fiber orientation is not consistent across the

  15. Novel energy modalities for catheter ablation of cardiac arrhythmias : Pitfalls and possibilities of potent power sources

    NARCIS (Netherlands)

    Neven, K.G.E.J.

    2014-01-01

    The acceptance of catheter ablation as treatment for cardiac arrhythmias is amongst others dependent on its success rate, a high initial success rate will increase physician and patient acceptance. One of the reasons why recurrence of arrhythmia after ablation is substantial is non-transmurality of

  16. Asymptomatic Ventricular Pre-excitation: Between Sudden Cardiac Death and Catheter Ablation.

    Science.gov (United States)

    Brugada, Josep; Keegan, Roberto

    2018-03-01

    Debate about the best clinical approach to the management of asymptomatic patients with ventricular pre-excitation and advice on whether or not to invasively stratify and ablate is on-going. Weak evidence about the real risk of sudden cardiac death and the potential benefit of catheter ablation has probably prevented the clarification of action in this not infrequent and sometimes conflicting clinical situation. After analysing all available data, real evidence-based medicine could be the alternative strategy for managing this group of patients. According to recent surveys, most electrophysiologists invasively stratify. Based on all accepted risk factors - younger age, male, associated structural heart disease, posteroseptal localisation, ability of the accessory pathway to conduct anterogradely at short intervals of ≤250 milliseconds and inducibility of sustained atrioventricular re-entrant tachycardia and/or atrial fibrillation - a shared decisionmaking process on catheter ablation is proposed.

  17. Pulmonary artery occlusion pressure estimation by transesophageal echocardiography: is simpler better?

    Science.gov (United States)

    Voga, Gorazd

    2008-01-01

    The measurement of pulmonary artery occlusion pressure (PAOP) is important for estimation of left ventricular filling pressure and for distinction between cardiac and non-cardiac etiology of pulmonary edema. Clinical assessment of PAOP, which relies on physical signs of pulmonary congestion, is uncertain. Reliable PAOP measurement can be performed by pulmonary artery catheter, but it is possible also by the use of echocardiography. Several Doppler variables show acceptable correlation with PAOP and can be used for its estimation in cardiac and critically ill patients. Noninvasive PAOP estimation should probably become an integral part of transthoracic and transesophageal echocardiographic evaluation in critically ill patients. However, the limitations of both methods should be taken into consideration, and in specific patients invasive PAOP measurement is still unavoidable, if the exact value of PAOP is needed.

  18. Asymptomatic Ventricular Pre-excitation: Between Sudden Cardiac Death and Catheter Ablation

    Science.gov (United States)

    Brugada, Josep

    2018-01-01

    Debate about the best clinical approach to the management of asymptomatic patients with ventricular pre-excitation and advice on whether or not to invasively stratify and ablate is on-going. Weak evidence about the real risk of sudden cardiac death and the potential benefit of catheter ablation has probably prevented the clarification of action in this not infrequent and sometimes conflicting clinical situation. After analysing all available data, real evidence-based medicine could be the alternative strategy for managing this group of patients. According to recent surveys, most electrophysiologists invasively stratify. Based on all accepted risk factors – younger age, male, associated structural heart disease, posteroseptal localisation, ability of the accessory pathway to conduct anterogradely at short intervals of ≤250 milliseconds and inducibility of sustained atrioventricular re-entrant tachycardia and/or atrial fibrillation – a shared decisionmaking process on catheter ablation is proposed. PMID:29636970

  19. Comparison of transcoelomic, contrast transcoelomic, and transesophageal echocardiography in anesthetized red-tailed hawks (Buteo jamaicensis).

    Science.gov (United States)

    Beaufrère, Hugues; Pariaut, Romain; Rodriguez, Daniel; Nevarez, Javier G; Tully, Thomas N

    2012-10-01

    To assess the agreement and reliability of cardiac measurements obtained with 3 echocardiographic techniques in anesthetized red-tailed hawks (Buteo jamaicensis). 10 red-tailed hawks. Transcoelomic, contrast transcoelomic, and transesophageal echocardiographic evaluations of the hawks were performed, and cineloops of imaging planes were recorded. Three observers performed echocardiographic measurements of cardiac variables 3 times on 3 days. The order in which hawks were assessed and echocardiographic techniques were used was randomized. Results were analyzed with linear mixed modeling, agreement was assessed with intraclass correlation coefficients, and variation was estimated with coefficients of variation. Significant differences were evident among the 3 echocardiographic methods for most measurements, and the agreement among findings was generally low. Interobserver agreement was generally low to medium. Intraobserver agreement was generally medium to high. Overall, better agreement was achieved for the left ventricular measurements and for the transesophageal approach than for other measurements and techniques. Echocardiographic measurements in hawks were not reliable, except when the left ventricle was measured by the same observer. Furthermore, cardiac morphometric measurements may not be clinically important. When measurements are required, one needs to consider that follow-up measurements should be performed by the same echocardiographer and should show at least a 20% difference from initial measurements to be confident that any difference is genuine.

  20. Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation - prospective study of 704 cases

    Science.gov (United States)

    Mateos, José Carlos Pachón; Mateos, Enrique I Pachón; Peña, Tomas G Santillana; Lobo, Tasso Julio; Mateos, Juán Carlos Pachón; Vargas, Remy Nelson A; Pachón, Carlos Thiene C; Acosta, Juán Carlos Zerpa

    2015-01-01

    Introduction Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. Objective This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Methods Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8±14 [17-84] years old), with mean EF of 0.66±0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. Results The mean esophageal displacement was 4 to 9.1cm (5.9±0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11±0.13ºC versus 1.1±0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Conclusion Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most

  1. Transcatheter radiofrequency ablation under the guidance of three-dimensional mapping for the treatment of complex cardiac arrhythmias

    International Nuclear Information System (INIS)

    Hong Lang; Wang Hong; Lai Hengli; Ying Qiulin; Chen Zhangqiang; Lu Linxiang; Qiu Yun; Xiao Chengwei

    2010-01-01

    Objective: To investigate the effectiveness and safety of transcatheter radiofrequency ablation guided by a three-dimensional mapping system (Ensite or Carto) for the treatment of complex cardiac arrhythmias. Methods: A cohort of 123 consecutive hospitalized inpatients during the period from February 2006 to December 2008 were selected for this study. These patients suffered from various arrhythmias, including paroxysmal atrial fibrillation (n = 58), persistent or permanent atrial fibrillation (n = 10), atrial flutter (n = 13), atrial tachycardia (n = 12) and ventricular tachycardia or frequent ventricular premature beats (n = 30). Transcatheter radiofrequency ablation for arrhythmias was performed under the guidance of an EnSite3000 / NavX or Array mapping system in 80 cases, and under the guidance of a CARTO mapping system in the remaining 43 cases. Results: Successful ablation of arrhythmias was obtained by single operation in 106 cases (86.18%), including 59 cases with atrial fibrillation, 11 cases with atrial flutter, 10 cases with atrial tachycardia, and 26 cases with ventricular tachycardia or premature ventricular beat.Ablation procedure was carried out and was successful in 10 cases with a successful rate of 94.31%, including 5 cases with atrial fibrillation, 1 case with recurred atrial flutter, 1 case with recurrent atrial tachycardia, and 3 cases with ventricular tachycardia or premature ventricular beat.After operation, complications occurred in 6 cases, including cardiac tamponade in 4 cases, distal embolism of the left anterior descending coronary artery in 1 case, and pulmonary embolism in 1 case. Conclusion: Three-dimensional mapping system can clearly and stereoscopically display the cardiac structures. Therefore, this technique is of great value in guiding the transcatheter radiofrequency ablation for complex arrhythmias, in improving the success rate of ablation and in increasing the safety of the procedure. (authors)

  2. Guidelines of the Indian Association of Cardiovascular and Thoracic Anaesthesiologists and Indian College of Cardiac Anaesthesia for perioperative transesophageal echocardiography fellowship examination

    Directory of Open Access Journals (Sweden)

    Kanchi Muralidhar

    2016-01-01

    Full Text Available During current medical care, perioperative transesophageal echocardiography (TEE has become a vital component of patient management, especially in cardiac operating rooms and in critical care medicine. Information derived from echocardiography has an important bearing on the patient′s outcome. The Indian Association of Cardiovascular and Thoracic Anaesthesiologists (IACTA has promoted the use of TEE during routine clinical care of patients undergoing cardiac surgery. An important mission of IACTA is to oversee training and certify anesthesiologists in the perioperative and intensive care use of TEE. The provision of "Fellowship" is by way of conducting IACTA - TEE fellowship (F-TEE examination. This has been done annually for the past 7 years using well-established curriculums by accredited national and international societies. Now, with the transformation and reconstitution of IACTA education and research cell into the newly formed Indian College of Cardiac Anaesthesia, F-TEE is bound to meet international standards. To ensure that the examinations are conducted in a transparent and foolproof manner, the guideline committee (formulated in 2010 of IACTA has taken the onus of formulating the guidelines for the same. These guidelines have been formally reviewed and updated since 2010 and are detailed here to serve as a guide to both the examinee and examiner ensuring standardization, efficiency, and competency of the IACTA F-TEE certification process.

  3. Towards Robot-Assisted Echocardiographic Monitoring in Catheterization Laboratories : Usability-Centered Manipulator for Transesophageal Echocardiography.

    Science.gov (United States)

    Pahl, Christina; Ebelt, Henning; Sayahkarajy, Mostafa; Supriyanto, Eko; Soesanto, Amiliana

    2017-08-15

    This paper proposes a robotic Transesophageal Echocardiography (TOE) system concept for Catheterization Laboratories. Cardiovascular disease causes one third of all global mortality. TOE is utilized to assess cardiovascular structures and monitor cardiac function during diagnostic procedures and catheter-based structural interventions. However, the operation of TOE underlies various conditions that may cause a negative impact on performance, the health of the cardiac sonographer and patient safety. These factors have been conflated and evince the potential of robot-assisted TOE. Hence, a careful integration of clinical experience and Systems Engineering methods was used to develop a concept and physical model for TOE manipulation. The motion of different actuators of the fabricated motorized system has been tested. It is concluded that the developed medical system, counteracting conflated disadvantages, represents a progressive approach for cardiac healthcare.

  4. 15. Sensitivity in visualizing vegetations in cardiac lead-induced endocarditis: A comparative study between transesophageal vs. transthoracic echocardiography

    Directory of Open Access Journals (Sweden)

    A. AlFagih

    2016-07-01

    Full Text Available Despite advancement in sterile cardiac device implantation techniques, wound infections and/or bacteremia remain a significant problem. The presence of a vegetation in lead-induced endocarditis (LIE is a critical factor that determines the management. Transthoracic (TTE and Transesophageal (TEE Echocardiography are two different cardiac modalities that are used for the detection of lead vegetation. However, it is not yet clear which of the two has the highest diagnostic accuracy. We aim to identify which of the two has the highest sensitivity. In addition, we aim to correlate the existence of a vegetation with blood and wound culture results. We conducted a chart review in 113 patients whom underwent lead extraction at Prince Sultan Cardiac Center in Saudi Arabia during the period of Jan, 2002 to Jul, 2015. Six patients underwent lead extraction twice, increasing the number to be a total of 119 cases. Out of the study cohort, we include 38 patients who had both TTE and TEE done prior to lead extraction. Data regarding TTE, TEE, as well as blood and wound cultures were collected from echocardiography and microbiology lab reports using a well-structured case report form.Of the study population, 21 patients (55.3% had lead vegetations visualized either by TTE or TEE. Nineteen patients had vegetations detected by TEE, compared to 6 patients only when TTE was used. The sensitivity of TEE and TTE were 90.5% (CI: 69.6–98.8% and 28.5% (95% CI: 11.3–52.1%, respectively. Blood and wound culture results showed that in the presence of a vegetation, blood cultures were positive in 55% of the cases (P = 0.036 while only 44.4% of those with vegetations had a positive wound culture (P = 0.347. TEE has higher sensitivity in detecting vegetations compared to TTE in LIE. The presence of a vegetation is more likely to be associated with a positive blood culture than a positive wound culture. Further studies ought to measure the accuracy of different

  5. Acquiring Multiview C-Arm Images to Assist Cardiac Ablation Procedures

    Directory of Open Access Journals (Sweden)

    Fallavollita Pascal

    2010-01-01

    Full Text Available CARTO XP is an electroanatomical cardiac mapping system that provides 3D color-coded maps of the electrical activity of the heart; however it is expensive and it can only use a single costly magnetic catheter for each patient intervention. Our approach consists of integrating fluoroscopic and electrical data from the RF catheters into the same image so as to better guide RF ablation, shorten the duration of this procedure, increase its efficacy, and decrease hospital cost when compared to CARTO XP. We propose a method that relies on multi-view C-arm fluoroscopy image acquisition for (1 the 3D reconstruction of the anatomical structure of interest, (2 the robust temporal tracking of the tip-electrode of a mapping catheter between the diastolic and systolic phases and (3 the 2D/3D registration of color coded isochronal maps directly on the 2D fluoroscopy image that would help the clinician guide the ablation procedure much more effectively. The method has been tested on canine experimental data.

  6. ECG-based 4D-dose reconstruction of cardiac arrhythmia ablation with carbon ion beams: application in a porcine model

    Science.gov (United States)

    Richter, Daniel; Immo Lehmann, H.; Eichhorn, Anna; Constantinescu, Anna M.; Kaderka, Robert; Prall, Matthias; Lugenbiel, Patrick; Takami, Mitsuru; Thomas, Dierk; Bert, Christoph; Durante, Marco; Packer, Douglas L.; Graeff, Christian

    2017-09-01

    Noninvasive ablation of cardiac arrhythmia by scanned particle radiotherapy is highly promising, but especially challenging due to cardiac and respiratory motion. Irradiations for catheter-free ablation in intact pigs were carried out at the GSI Helmholtz Center in Darmstadt using scanned carbon ions. Here, we present real-time electrocardiogram (ECG) data to estimate time-resolved (4D) delivered dose. For 11 animals, surface ECGs and temporal structure of beam delivery were acquired during irradiation. R waves were automatically detected from surface ECGs. Pre-treatment ECG-triggered 4D-CT phases were synchronized to the R-R interval. 4D-dose calculation was performed using GSI’s in-house 4D treatment planning system. Resulting dose distributions were assessed with respect to coverage (D95 and V95), heterogeneity (HI  =  D5-D95) and normal tissue exposure. Final results shown here were performed offline, but first calculations were started shortly after irradiation The D95 for TV and PTV was above 95% for 10 and 8 out of 11 animals, respectively. HI was reduced for PTV versus TV volumes, especially for some of the animals targeted at the atrioventricular junction, indicating residual interplay effects due to cardiac motion. Risk structure exposure was comparable to static and 4D treatment planning simulations. ECG-based 4D-dose reconstruction is technically feasible in a patient treatment-like setting. Further development of the presented approach, such as real-time dose calculation, may contribute to safe, successful treatments using scanned ion beams for cardiac arrhythmia ablation.

  7. Giant right coronary artery aneurysm with unusual physiology: Role of intraoperative transesophageal echocardiography

    Directory of Open Access Journals (Sweden)

    David M Orozco

    2012-01-01

    Full Text Available A 65-year-old woman presented with a history of dyspnea and atypical chest pain. She was diagnosed with a non-ST-segment elevation myocardial infarction due to a giant right coronary artery aneurysm. After a failed percutaneous embolization, she was scheduled for right coronary artery aneurysm resection, posterior descending artery revascularization and mitral valve repair. During the induction of anesthesia and institution of mechanical ventilation, the patient suffered cardiovascular collapse. The transesophageal echocardiographic examination revealed tamponade physiology owing to compression of the cardiac chambers by the unruptured aneurysm, which resolved with the sternotomy. The surgery was carried out uneventfully.

  8. Three dimensional transesophageal echocardiography guided transcatheter closure of mitral paraprosthesis regurgitation – A case report

    Directory of Open Access Journals (Sweden)

    Vinay Kumar Sharma

    2013-05-01

    Full Text Available The last two decades have witnessed vast advances in the field of cardiac intervention, particularly with regard to nonsurgical closure of structural heart diseases including para prosthetic valvular leaks. The use of imaging techniques to guide even well-established procedures enhances the efficiency and safety of these procedures. The present case report aims to highlight the role of three dimensional transesophageal echocardiography in pre, intra and post operative management of patients with mitral para prosthetic valvular regurgitation.

  9. Black-box modeling to estimate tissue temperature during radiofrequency catheter cardiac ablation: feasibility study on an agar phantom model

    International Nuclear Information System (INIS)

    Blasco-Gimenez, Ramón; Lequerica, Juan L; Herrero, Maria; Hornero, Fernando; Berjano, Enrique J

    2010-01-01

    The aim of this work was to study linear deterministic models to predict tissue temperature during radiofrequency cardiac ablation (RFCA) by measuring magnitudes such as electrode temperature, power and impedance between active and dispersive electrodes. The concept involves autoregressive models with exogenous input (ARX), which is a particular case of the autoregressive moving average model with exogenous input (ARMAX). The values of the mode parameters were determined from a least-squares fit of experimental data. The data were obtained from radiofrequency ablations conducted on agar models with different contact pressure conditions between electrode and agar (0 and 20 g) and different flow rates around the electrode (1, 1.5 and 2 L min −1 ). Half of all the ablations were chosen randomly to be used for identification (i.e. determination of model parameters) and the other half were used for model validation. The results suggest that (1) a linear model can be developed to predict tissue temperature at a depth of 4.5 mm during RF cardiac ablation by using the variables applied power, impedance and electrode temperature; (2) the best model provides a reasonably accurate estimate of tissue temperature with a 60% probability of achieving average errors better than 5 °C; (3) substantial errors (larger than 15 °C) were found only in 6.6% of cases and were associated with abnormal experiments (e.g. those involving the displacement of the ablation electrode) and (4) the impact of measuring impedance on the overall estimate is negligible (around 1 °C)

  10. Incremental value of three-dimensional transesophageal echocardiography over two-dimensional transesophageal echocardiography in the assessment of Lambl's excrescences and nodules of Arantius on the aortic valve.

    Science.gov (United States)

    Dumaswala, Bhavin; Dumaswala, Komal; Hsiung, Ming Chon; Quiroz, Luis David Meggo; Sungur, Aylin; Escanuela, Maximilliano German Amado; Mehta, Kruti; Oz, Tugba Kemaloglu; Bhagatwala, Kunal; Karia, Nidhi M; Nanda, Navin C

    2013-09-01

    In this retrospective study, we identified 7 cases where Lambl's excrescences were identified by two-dimensional transesophageal echocardiography (2DTEE) and also had live/real time three-dimensional transesophageal echocardiography (3DTEE) studies available for comparison. We subsequently assessed them for the presence of Lambl's excrescences (LE) and nodules of Arantius (NA) on the aortic valve. After their identification, we qualitatively and quantitatively organized our findings by number, cusp location, measurements, and orientation if applicable. A greater number of LE was found by 3DTEE than 2DTEE (19 vs. 11, respectively). In all 3DTEE studies, their cusp attachment site, their x-, y-, and z-axis measurements, and orientation were clearly visualized and described. Only 3DTEE studies provided confident visualization of the cusp attachment sites. Similarly, a greater number of NA was found by 3DTEE than 2DTEE (21 vs. 5, respectively). The triad of NA was visualized in all 3DTEE studies and each was described using its x-, y-, and z- axis measurements. Only three 2DTEE studies provided reliable identification of the NA. In conclusion, we present further evidence of the incremental value of 3DTEE over 2DTEE in the qualitative and quantitative assessment of cardiac structures including LE and NA on the aortic valve. © 2013, Wiley Periodicals, Inc.

  11. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    Science.gov (United States)

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  12. Incremental benefit of three-dimensional transesophageal echocardiography in the assessment of a primary pericardial hemangioma.

    Science.gov (United States)

    Arisha, Mohammed J; Hsiung, Ming C; Nanda, Navin C; ElKaryoni, Ahmed; Mohamed, Ahmed H; Wei, Jeng

    2017-08-01

    Hemangiomas are rarely found in the heart and pericardial involvement is even more rare. We report a case of primary pericardial hemangioma, in which three-dimensional transesophageal echocardiography (3DTEE) provided incremental benefit over standard two-dimensional images. Our case also highlights the importance of systematic cropping of the 3D datasets in making a diagnosis of pericardial hemangioma with a greater degree of certainty. In addition, we also provide a literature review of the features of cardiac/pericardial hemangiomas in a tabular form. © 2017, Wiley Periodicals, Inc.

  13. Temperature-controlled radiofrequency ablation of cardiac tissue

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1999-01-01

    BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available for the frequ......BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available...... for the frequently used temperature-controlled mode. The purpose of the present experimental study was to evaluate the impact during temperature-controlled radiofrequency ablation of three basic factors regarding electrode-tissue contact and convective cooling on lesion size. METHODS AND RESULTS: In vitro strips......-controlled radiofrequency ablation increased external cooling of the electrode tip due to either flow of the surrounding liquid or poor electrode tissue contact, as exemplified by perpendicular versus parallel electrode orientation, increases lesion size significantly. This is in contrast to the impact of these factors...

  14. Cardiac memory in patients with Wolff-Parkinson-White syndrome: noninvasive imaging of activation and repolarization before and after catheter ablation.

    Science.gov (United States)

    Ghosh, Subham; Rhee, Edward K; Avari, Jennifer N; Woodard, Pamela K; Rudy, Yoram

    2008-08-26

    Cardiac memory refers to a change in ventricular repolarization induced by and persisting for minutes to months after cessation of a period of altered ventricular activation (eg, resulting from pacing or preexcitation in patients with Wolff-Parkinson-White syndrome). ECG imaging (ECGI) is a novel imaging modality for noninvasive electroanatomic mapping of epicardial activation and repolarization. Fourteen pediatric patients with Wolff-Parkinson-White syndrome and no other congenital disease, were imaged with ECGI a day before and 45 minutes, 1 week, and 1 month after successful catheter ablation. ECGI determined that preexcitation sites were consistent with sites of successful ablation in all cases to within a 1-hour arc of each atrioventricular annulus. In the preexcited rhythm, activation-recovery interval (ARI) was the longest (349+/-6 ms) in the area of preexcitation leading to high average base-to-apex ARI dispersion of 95+/-9 ms (normal is approximately 40 ms). The ARI dispersion remained the same 45 minutes after ablation, although the activation sequence was restored to normal. ARI dispersion was still high (79+/-9 ms) 1 week later and returned to normal (45+/-6 ms) 1 month after ablation. The study demonstrates that ECGI can noninvasively localize ventricular insertion sites of accessory pathways to guide ablation and evaluate its outcome in pediatric patients with Wolff-Parkinson-White syndrome. Wolff-Parkinson-White is associated with high ARI dispersion in the preexcited rhythm that persists after ablation and gradually returns to normal over a period of 1 month, demonstrating the presence of cardiac memory. The 1-month time course is consistent with transcriptional reprogramming and remodeling of ion channels.

  15. Diagnosis of cardiac tamponade with transesophageal echocardiography following the induction of anesthesia for suspected testicular torsion

    Directory of Open Access Journals (Sweden)

    Stephen M McHugh

    2015-01-01

    Full Text Available Transesophageal echocardiography (TEE is a valuable tool for evaluating hemodynamic instability in patients under general anesthesia. We present the case of a 28-year-old man who presented with complaints of testicular pain concerning for testicular torsion. After induction of general anesthesia for scrotal exploration and possible orchiopexy, the patient developed severe and persistent hypotension. Using intraoperative TEE, the diagnosis of pericardial tamponade was made, and an emergent pericardial window was performed.

  16. Esophageal Perforation due to Transesophageal Echocardiogram: New Endoscopic Clip Treatment

    Directory of Open Access Journals (Sweden)

    John Robotis

    2014-07-01

    Full Text Available Esophageal perforation due to transesophageal echocardiogram (TEE during cardiac surgery is rare. A 72-year-old female underwent TEE during an operation for aortic valve replacement. Further, the patient presented hematemesis. Gastroscopy revealed an esophageal bleeding ulcer. Endoscopic therapy was successful. Although a CT scan excluded perforation, the patient became febrile, and a second gastroscopy revealed a big perforation at the site of ulcer. The patient's clinical condition required endoscopic intervention with a new OTSC® clip (Ovesco Endoscopy, Tübingen, Germany. The perforation was successfully sealed. The patient remained on intravenous antibiotics, proton pump inhibitors and parenteral nutrition for few days, followed by enteral feeding. She was discharged fully recovered 3 months later. We clearly demonstrate an effective, less invasive treatment of an esophageal perforation with a new endoscopic clip.

  17. [Transesophageal echocardiography diagnosis of ruptured aneurysm of the Valsalva sinus associated with aneurysm of the interatrial septum].

    Science.gov (United States)

    Imperadore, Ferdinando; Ferro, Aldo; Graffigna, Angelo; Vergara, Giuseppe

    2002-01-01

    Aneurysms of the sinus of Valsalva are uncommon heart defects that often remain undetected unless rupture occurs. They have been reported in association with other cardiac anomalies. The present case report deals with a 51-year-old man who was referred to our division with a diagnosis of recent-onset progressive heart failure. Echocardiographic evaluation, both transthoracic and transesophageal, disclosed rupture of an aneurysm of the non-coronary sinus of Valsalva into the right atrium. This anomaly was associated with an aneurysm of the atrial septum.

  18. Aortic root segmentation in 4D transesophageal echocardiography

    Science.gov (United States)

    Chechani, Shubham; Suresh, Rahul; Patwardhan, Kedar A.

    2018-02-01

    The Aortic Valve (AV) is an important anatomical structure which lies on the left side of the human heart. The AV regulates the flow of oxygenated blood from the Left Ventricle (LV) to the rest of the body through aorta. Pathologies associated with the AV manifest themselves in structural and functional abnormalities of the valve. Clinical management of pathologies often requires repair, reconstruction or even replacement of the valve through surgical intervention. Assessment of these pathologies as well as determination of specific intervention procedure requires quantitative evaluation of the valvular anatomy. 4D (3D + t) Transesophageal Echocardiography (TEE) is a widely used imaging technique that clinicians use for quantitative assessment of cardiac structures. However, manual quantification of 3D structures is complex, time consuming and suffers from inter-observer variability. Towards this goal, we present a semiautomated approach for segmentation of the aortic root (AR) structure. Our approach requires user-initialized landmarks in two reference frames to provide AR segmentation for full cardiac cycle. We use `coarse-to-fine' B-spline Explicit Active Surface (BEAS) for AR segmentation and Masked Normalized Cross Correlation (NCC) method for AR tracking. Our method results in approximately 0.51 mm average localization error in comparison with ground truth annotation performed by clinical experts on 10 real patient cases (139 3D volumes).

  19. Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: derivation of cardiac output.

    Science.gov (United States)

    Tibby, S M; Hatherill, M; Murdoch, I A

    2000-06-01

    To ascertain if cardiac output (CO) could be derived from blood flow velocity measured in the descending aorta of ventilated children by transesophageal Doppler ultrasonography (TED) without the need for direct aortic cross sectional area measurement, and to evaluate the ability of TED to follow changes in CO when compared with femoral artery thermodilution. Prospective, comparison study. A 16-bed pediatric intensive care unit of a university hospital. A total of 100 ventilated infants and children aged 4 days to 18 yrs (median age, 27 months). Diagnoses included postcardiac surgery (n = 58), sepsis/multiple organ failure (n = 32), respiratory disease (n = 5), and other (n = 5). A total of 55 patients were receiving inotropes or vasodilators. When patients were hemodynamically stable, a TED probe was placed into the distal esophagus to obtain optimal signal, and minute distance (MD) was recorded. Five consecutive MD measurements were made concurrently with five femoral artery thermodilution measurements, and the concurrent measurements were averaged. CO was then manipulated by fluid administration or inotrope adjustment, and the readings were repeated. Femoral artery thermodilution CO ranged from 0.32 to 9.19 L/min, (median, 2.46 L/min), and encompassed a wide range of high and low flow states. Theoretical consideration revealed the optimal TED estimate for CO to be (MD x patient height2 x 10(-7)). Linear regression analysis yielded a power function model such that: estimated CO = 1.158 x (MD x height2 x 10(-7))(0.785), r2 = 0.879, standard error of the estimate = 0.266. Inclusion of a correction factor for potential changes in aortic cross-sectional area with hypo- and hypertension did not appreciably improve the predictive value of the model. MD was able to follow percentage changes in CO, giving a mean bias of 0.87% (95% confidence interval -0.85% to 2.59%), and limits of agreement of +/- 16.82%. The median coefficient of variation for MD was 3.3%. TED provides

  20. Right Atrial Dual-loop Reentry Tachycardia after Cardiac Surgery: Prevalence, Electrophysiologic Characteristics and Ablation Outcomes.

    Science.gov (United States)

    Yang, Jian-du; Sun, Qi; Guo, Xiao-Gang; Zhou, Gong-Bu; Liu, Xu; Luo, Bin; Wei, Hui-Qiang; Santangeli, Pasquale; Liang, Jackson J; Ma, Jian

    2018-04-03

    Right atrial dual-loop reentry tachycardia has been described in patients with open-heart surgery. However, the prevalence, electrophysiologic substrate and ablation outcomes have been poorly characterized. We aimed to investigate the prevalence, electrophysiologic substrate and ablation outcomes for RA dual-loop reentry tachycardia following cardiac surgery. We identified all patients with atrial tachycardia after cardiac surgery. We compared electrophysiologic findings and outcomes of those with RA dual-loop reentry tachycardia versus a control group of patients with RA macro-reentrant arrhythmias in the setting of linear RA free wall (FW) scar. Out of 127 patients with 152 post-surgical atrial tachycardias (ATs), 28 (18.4%) had diagnosis of RA dual-loop reentry and 24/28 (85.7%) had tricuspid annular (TA) reentry combined with FW incisional reentry. An incision length > 51.5mm along the FW predicted the substrate for a second loop. In 22/23 patients (95.7%) with initial ablation in the cavo-tricuspid isthmus, a change in the interval between Halo d to CS p could be recorded, while 15/23 patients (65.2%) had CS activation pattern change. Complete success was achieved in 25/28 (89.3%) and 64/69 (92.8%) in the dual-loop reentry and control groups, respectively. After mean follow-up of 33.9±24.2 months, 24/28 (85.7%) and 60/69 (86.95%) were free of arrhythmias after initial procedure in two groups. The prevalence of RA dual-loop reentry is 18.4% among ATs with prior atriotomy scar. A long incision should alert physician the possibility of the second loop at the FW. Halo and CS activation pattern are important clues for circuit transformation. Copyright © 2018. Published by Elsevier Inc.

  1. Three-dimensional transesophageal echocardiography of the atrial septal defects

    Directory of Open Access Journals (Sweden)

    Romero-Cárdenas Ángel

    2008-07-01

    Full Text Available Abstract Transesophageal echocardiography has advantages over transthoracic technique in defining morphology of atrial structures. Even though real time three-dimensional echocardiographic imaging is a reality, the off-line reconstruction technique usually allows to obtain higher spatial resolution images. The purpose of this study was to explore the accuracy of off-line three-dimensional transesophageal echocardiography in a spectrum of atrial septal defects by comparing them with representative anatomic specimens.

  2. Obstructed bi-leaflet prosthetic mitral valve imaging with real-time three-dimensional transesophageal echocardiography.

    Science.gov (United States)

    Shimbo, Mai; Watanabe, Hiroyuki; Kimura, Shunsuke; Terada, Mai; Iino, Takako; Iino, Kenji; Ito, Hiroshi

    2015-01-01

    Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) can provide unique visualization and better understanding of the relationship among cardiac structures. Here, we report the case of an 85-year-old woman with an obstructed mitral prosthetic valve diagnosed promptly by RT3D-TEE, which clearly showed a leaflet stuck in the closed position. The opening and closing angles of the valve leaflets measured by RT3D-TEE were compatible with those measured by fluoroscopy. Moreover, RT3D-TEE revealed, in the ring of the prosthetic valve, thrombi that were not visible on fluoroscopy. RT3D-TEE might be a valuable diagnostic technique for prosthetic mitral valve thrombosis. © 2014 Wiley Periodicals, Inc.

  3. Orthogonal Views of Coronary Vessels: A Method for Imaging the Delivery of Blood Cardioplegia Using Transesophageal Echocardiography.

    Science.gov (United States)

    Maracaja Neto, Luiz F; Modak, Raj; Schonberger, Robert B

    2017-04-01

    Coronary blood flow can be disrupted during cardiac interventions such as mitral valve surgeries, left atrial appendage ligation, transcatheter aortic valve implantation, and aortic procedures involving reimplantation of coronary buttons. Although difficult to accomplish, coronary imaging using transesophageal echocardiography can be performed by the use of orthogonal imaging with the ability for real-time tilt for angle adjustment. The technique described herein allows imaging of the right coronary artery, left main coronary artery bifurcation, left anterior descending, and circumflex coronary arteries. The imaging is facilitated by acquisition during the delivery of blood cardioplegia. Coronary sinus and great cardiac vein imaging also can be obtained during the delivery of retrograde cardioplegia. Although further studies are needed, this imaging technique may prove useful in procedures where coronary flow disruption is suspected or as an additional parameter to confirm delivery of cardioplegia.

  4. Value of multislice computed tomography angiography of the thorax in preparation for catheter ablation for the treatment of atrial fibrillation: The impact of unexpected cardiac and extracardiac findings on patient care

    Energy Technology Data Exchange (ETDEWEB)

    Wissner, Erik; Wellnitz, Clinton V.; Srivathsan, Komandoor; Scott, Luis R. [Mayo Clinic Arizona - Mayo Clinic Hospital, Cardiovascular Diseases, 5777 East Mayo Boulevard, Phoenix, AZ 85054 (United States); Altemose, Gregory T. [Mayo Clinic Arizona - Mayo Clinic Hospital, Cardiovascular Diseases, 5777 East Mayo Boulevard, Phoenix, AZ 85054 (United States)], E-mail: altemose.gregory@mayo.edu

    2009-11-15

    Objective: In patients referred for catheter ablation for the treatment of atrial fibrillation, multislice computed tomography angiography of the thorax is routinely performed to assess pulmonary vein anatomy. We sought to investigate the incidence of unexpected cardiac and extracardiac findings in this select patient population and to establish how these findings influence subsequent patient care. Methods: Ninety-five patients (mean age 62 {+-} 10 years, 35% female) referred to our institution for ablation therapy for atrial fibrillation between July 2003 and October 2007 underwent multislice computed tomography angiography of the thorax. Radiologists interpreted all images. Need for additional testing, consultation and eventual diagnosis were assessed by electronic record review. Results: A total of 83 (5 cardiac, 78 extracardiac) unexpected findings were observed in 50/95 (53%) of patients. The findings prompted 23 additional tests (5 cardiac, 18 noncardiac) in 15/95 (16%) of patients and 8 subsequent referrals in 7/95 (7%) patients. In 6 patients the findings significantly altered future patient care and resulted in postponement of ablation therapy in 4 patients. In 2 patients, extracardiac findings (pulmonary emboli and adenocarcinoma of the lung) were of potentially life-saving consequence. Conclusions: In patients undergoing multislice computed tomography angiography of the thorax in anticipation of planned catheter ablation therapy for the treatment of atrial fibrillation, unexpected findings are common and of potentially significant value. In comparison, there is a higher prevalence of unexpected extracardiac, rather than cardiac findings. Further investigation of these findings may lead to postponement of ablation therapy, but may also be of potentially lifesaving consequence.

  5. Value of multislice computed tomography angiography of the thorax in preparation for catheter ablation for the treatment of atrial fibrillation: The impact of unexpected cardiac and extracardiac findings on patient care

    International Nuclear Information System (INIS)

    Wissner, Erik; Wellnitz, Clinton V.; Srivathsan, Komandoor; Scott, Luis R.; Altemose, Gregory T.

    2009-01-01

    Objective: In patients referred for catheter ablation for the treatment of atrial fibrillation, multislice computed tomography angiography of the thorax is routinely performed to assess pulmonary vein anatomy. We sought to investigate the incidence of unexpected cardiac and extracardiac findings in this select patient population and to establish how these findings influence subsequent patient care. Methods: Ninety-five patients (mean age 62 ± 10 years, 35% female) referred to our institution for ablation therapy for atrial fibrillation between July 2003 and October 2007 underwent multislice computed tomography angiography of the thorax. Radiologists interpreted all images. Need for additional testing, consultation and eventual diagnosis were assessed by electronic record review. Results: A total of 83 (5 cardiac, 78 extracardiac) unexpected findings were observed in 50/95 (53%) of patients. The findings prompted 23 additional tests (5 cardiac, 18 noncardiac) in 15/95 (16%) of patients and 8 subsequent referrals in 7/95 (7%) patients. In 6 patients the findings significantly altered future patient care and resulted in postponement of ablation therapy in 4 patients. In 2 patients, extracardiac findings (pulmonary emboli and adenocarcinoma of the lung) were of potentially life-saving consequence. Conclusions: In patients undergoing multislice computed tomography angiography of the thorax in anticipation of planned catheter ablation therapy for the treatment of atrial fibrillation, unexpected findings are common and of potentially significant value. In comparison, there is a higher prevalence of unexpected extracardiac, rather than cardiac findings. Further investigation of these findings may lead to postponement of ablation therapy, but may also be of potentially lifesaving consequence.

  6. Annular dynamics of memo3D annuloplasty ring evaluated by 3D transesophageal echocardiography.

    Science.gov (United States)

    Nishi, Hiroyuki; Toda, Koichi; Miyagawa, Shigeru; Yoshikawa, Yasushi; Fukushima, Satsuki; Yoshioka, Daisuke; Sawa, Yoshiki

    2018-04-01

    We assessed the mitral annular motion after mitral valve repair with the Sorin Memo 3D® (Sorin Group Italia S.r.L., Saluggia, Italy), which is a unique complete semirigid annuloplasty ring intended to restore the systolic profile of the mitral annulus while adapting to the physiologic dynamism of the annulus, using transesophageal real-time three-dimensional echocardiography. 17 patients (12 male; mean age 60.4 ± 14.9 years) who underwent mitral annuloplasty using the Memo 3D ring were investigated. Mitral annular motion was assessed using QLAB®version8 allowing for a full evaluation of the mitral annulus dynamics. The mitral annular dimensions were measured throughout the cardiac cycle using 4D MV assessment2® while saddle shape was assessed through sequential measurements by RealView®. Saddle shape configuration of the mitral annulus and posterior and anterior leaflet motion could be observed during systole and diastole. The mitral annular area changed during the cardiac cycle by 5.7 ± 1.8%.The circumference length and diameter also changed throughout the cardiac cycle. The annular height was significantly higher in mid-systole than in mid-diastole (p 3D ring maintained a physiological saddle-shape configuration throughout the cardiac cycle. Real-time three-dimensional echocardiography analysis confirmed the motion and flexibility of the Memo 3D ring upon implantation.

  7. Transesophageal Ultrasonography for Lung Cancer Staging

    DEFF Research Database (Denmark)

    Konge, Lars; Annema, Jouke; Vilmann, Peter

    2013-01-01

    Accurate mediastinal nodal staging is essential for patients with resectable non-small-cell lung cancer and is achieved by combined endobronchial ultrasound and transesophageal endoscopic ultrasound (EUS). Training requirements for EUS-guided fine-needle aspiration (FNA) for lung cancer staging...

  8. Assessments of pulmonary vein and left atrial anatomical variants in atrial fibrillation patients for catheter ablation with cardiac CT

    International Nuclear Information System (INIS)

    Chen, Jing; Yang, Zhi-Gang; Xu, Hua-Yan; Shi, Ke; Long, Qi-Hua; Guo, Ying-Kun

    2017-01-01

    To provide a road map of pulmonary vein (PV) and left atrial (LA) variants in patients with atrial fibrillation (AF) before catheter ablation procedure using cardiac CT. Cardiac CT was performed in 1420 subjects for accurate anatomical information, including 710 patients with AF and 710 matched controls without AF. PV variants, PV ostia and spatial orientation, LA enlargement, and left atrial diverticulum (LAD) were measured, respectively. Differences between these two groups were also respectively compared. Some risk factors for the occurrence of LAD were analyzed. In total, PV variants were observed in 202 (28.5 %) patients with AF patients and 206 (29.0 %) controls without AF (p = 0.8153). The ostial sizes of all accessory veins were generally smaller than those of the typical four PVs (p = 0.0153 to 0.3958). There was a significant difference of LA enlargement between the AF and control groups (36.3 % vs. 12.5 %, p < 0.0001), while the prevalence of LAD was similar in these two groups (43.2 % vs. 41.9 %, p = 0.6293). PV variants are common. Detailed knowledge of PVs and LA variants are helpful for providing anatomical road map to determine ablation strategy. (orig.)

  9. Assessments of pulmonary vein and left atrial anatomical variants in atrial fibrillation patients for catheter ablation with cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jing; Yang, Zhi-Gang; Xu, Hua-Yan; Shi, Ke; Long, Qi-Hua [Sichuan University, Department of Radiology, West China Hospital, Chengdu, Sichuan (China); Guo, Ying-Kun [Sichuan University, Department of Radiology, West China Second University Hospital, Chengdu (China)

    2017-02-15

    To provide a road map of pulmonary vein (PV) and left atrial (LA) variants in patients with atrial fibrillation (AF) before catheter ablation procedure using cardiac CT. Cardiac CT was performed in 1420 subjects for accurate anatomical information, including 710 patients with AF and 710 matched controls without AF. PV variants, PV ostia and spatial orientation, LA enlargement, and left atrial diverticulum (LAD) were measured, respectively. Differences between these two groups were also respectively compared. Some risk factors for the occurrence of LAD were analyzed. In total, PV variants were observed in 202 (28.5 %) patients with AF patients and 206 (29.0 %) controls without AF (p = 0.8153). The ostial sizes of all accessory veins were generally smaller than those of the typical four PVs (p = 0.0153 to 0.3958). There was a significant difference of LA enlargement between the AF and control groups (36.3 % vs. 12.5 %, p < 0.0001), while the prevalence of LAD was similar in these two groups (43.2 % vs. 41.9 %, p = 0.6293). PV variants are common. Detailed knowledge of PVs and LA variants are helpful for providing anatomical road map to determine ablation strategy. (orig.)

  10. Lesion size estimator of cardiac radiofrequency ablation at different common locations with different tip temperatures.

    Science.gov (United States)

    Lai, Yu-Chi; Choy, Young Bin; Haemmerich, Dieter; Vorperian, Vicken R; Webster, John G

    2004-10-01

    Finite element method (FEM) analysis has become a common method to analyze the lesion formation during temperature-controlled radiofrequency (RF) cardiac ablation. We present a process of FEM modeling a system including blood, myocardium, and an ablation catheter with a thermistor embedded at the tip. The simulation used a simple proportional-integral (PI) controller to control the entire process operated in temperature-controlled mode. Several factors affect the lesion size such as target temperature, blood flow rate, and application time. We simulated the time response of RF ablation at different locations by using different target temperatures. The applied sites were divided into two groups each with a different convective heat transfer coefficient. The first group was high-flow such as the atrioventricular (AV) node and the atrial aspect of the AV annulus, and the other was low-flow such as beneath the valve or inside the coronary sinus. Results showed the change of lesion depth and lesion width with time, under different conditions. We collected data for all conditions and used it to create a database. We implemented a user-interface, the lesion size estimator, where the user enters set temperature and location. Based on the database, the software estimated lesion dimensions during different applied durations. This software could be used as a first-step predictor to help the electrophysiologist choose treatment parameters.

  11. Relationships between cardiac innervation/perfusion imbalance and ventricular arrhythmias: impact on invasive electrophysiological parameters and ablation procedures

    International Nuclear Information System (INIS)

    Gimelli, Alessia; Menichetti, Francesca; Soldati, Ezio; Liga, Riccardo; Vannozzi, Andrea; Bongiorni, Maria Grazia; Marzullo, Paolo

    2016-01-01

    To assess the relationship between regional myocardial perfusion and sympathetic innervation parameters at myocardial scintigraphy and intra-cavitary electrophysiological data in patients with ventricular arrhythmias (VA) submitted to invasive electrophysiological study and ablation procedure. Sixteen subjects underwent invasive electrophysiological study with electroanatomical mapping (EAM) followed by trans-catheter ablations of VA. Before ablation all patients were studied with a combined evaluation of regional myocardial perfusion and sympathetic innervation by means of tomographic "9"9"mTc-tetrofosmin and "1"2"3I- metaiodobenzylguanidine cadmium-zinc-telluride (CZT) scintigraphies, respectively. Off-line spatial co-registration of CZT perfusion and innervation data with the three-dimensional EAM reconstruction was performed in every patient. CZT revealed the presence of myocardial scar in 55 (20 %) segments. Of the viable myocardial segments, 131 (60 %) presented a preserved adrenergic innervation, while 86 (40 %) showed a significantly depressed innervation (i.e. innervation/perfusion mismatch). On EAM, the invasively measured intra-cavitary voltage was significantly lower in scarred segments than in viable ones (1.7 ± 1.5 mV vs. 4.0 ± 2.2 mV, P < 0.001). Interestingly, among the viable segments, those showing an innervation/perfusion mismatch presented a significantly lower intra-cavitary voltage than those with preserved innervation (1.9 ± 2.5 mV vs. 4.7 ± 2.3 mV, P < 0.001). Intra-cardiac ablation was performed in 63 (23 %) segments. On multivariate analysis, after correction for scar burden, the segments showing an innervation/perfusion mismatch remained the most frequent ablation targets (OR 5.6, 95 % CI 1.5-20.8; P = 0.009). In patients with VA, intra-cavitary electrical abnormalities frequently originate at the level of viable myocardial segments with depressed sympathetic innervation that frequently represents the ultimate ablation target. (orig.)

  12. Relationships between cardiac innervation/perfusion imbalance and ventricular arrhythmias: impact on invasive electrophysiological parameters and ablation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Gimelli, Alessia [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); Menichetti, Francesca; Soldati, Ezio; Liga, Riccardo; Vannozzi, Andrea; Bongiorni, Maria Grazia [University Hospital of Pisa, Cardio-Thoracic and Vascular Department, Pisa (Italy); Marzullo, Paolo [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); CNR, Institute of Clinical Physiology, Pisa (Italy)

    2016-12-15

    To assess the relationship between regional myocardial perfusion and sympathetic innervation parameters at myocardial scintigraphy and intra-cavitary electrophysiological data in patients with ventricular arrhythmias (VA) submitted to invasive electrophysiological study and ablation procedure. Sixteen subjects underwent invasive electrophysiological study with electroanatomical mapping (EAM) followed by trans-catheter ablations of VA. Before ablation all patients were studied with a combined evaluation of regional myocardial perfusion and sympathetic innervation by means of tomographic {sup 99m}Tc-tetrofosmin and {sup 123}I- metaiodobenzylguanidine cadmium-zinc-telluride (CZT) scintigraphies, respectively. Off-line spatial co-registration of CZT perfusion and innervation data with the three-dimensional EAM reconstruction was performed in every patient. CZT revealed the presence of myocardial scar in 55 (20 %) segments. Of the viable myocardial segments, 131 (60 %) presented a preserved adrenergic innervation, while 86 (40 %) showed a significantly depressed innervation (i.e. innervation/perfusion mismatch). On EAM, the invasively measured intra-cavitary voltage was significantly lower in scarred segments than in viable ones (1.7 ± 1.5 mV vs. 4.0 ± 2.2 mV, P < 0.001). Interestingly, among the viable segments, those showing an innervation/perfusion mismatch presented a significantly lower intra-cavitary voltage than those with preserved innervation (1.9 ± 2.5 mV vs. 4.7 ± 2.3 mV, P < 0.001). Intra-cardiac ablation was performed in 63 (23 %) segments. On multivariate analysis, after correction for scar burden, the segments showing an innervation/perfusion mismatch remained the most frequent ablation targets (OR 5.6, 95 % CI 1.5-20.8; P = 0.009). In patients with VA, intra-cavitary electrical abnormalities frequently originate at the level of viable myocardial segments with depressed sympathetic innervation that frequently represents the ultimate ablation target

  13. Morpho-functional assessment of interatrial septum: a transesophageal echocardiographic study.

    Science.gov (United States)

    Galzerano, D; Tuccillo, B; Lama, D; Paolisso, G; Mirra, G; Giasi, M

    1995-08-01

    Despite the increasing number of reports on lipomatous hypertrophy of interatrial septum, a standardization of measurement of the dimensions of the interatrial septum (IAS) in the different phases of cardiac cycle has not been reported. Moreover, no data on modification of thickness with age and in specific cardiac diseases are available. Our purpose was to study whether the changes of thickness and thinning of IAS may be related to age, left atrial dimension, cardiac cycle and different cardiac diseases. 248 patients (mean age 52.7 +/- 19.9 years) underwent transthoracic (TTE) and transesophageal (TEE) echocardiography. IAS was measured at the constant regions anterior and posterior to the fossa ovalis. IAS thickness (tk), thinning (th) and % thinning (% th) were measured. IAS thickness ranged from 4 to 13 mm at the time of ventricular end-systolic phase (mean 6.7 +/- 1.9 mm) and from 6 to 16 mm at the time of atrial systole (mean 9.9 +/- 1.8 mm); significant statistical difference between these values was found (P IAS thinning ranged from 1 to 7 mm (mean 3.42 +/- 1.8) while % IAS thinning from 18 to 76% (mean 36.53 +/- 16.36%). Statistical analysis showed a significant positive correlation between age and ventricular end-systolic thickness and atrial systolic thickness and thinning. An insignificant correlation was found between age and % IAS thinning and between left atrial dimension and IAS tk and th. Our results demonstrate that IAS thickness increases by age; no correlation exists between IAS thinning and age. There is no difference between IAS thickness and thinning in patients with or without cardiac disease. We believe that the thickness of IAS can be considered hypertrophic only if it exceeds the value of 15 mm during both ventricular end-systolic and atrial systolic phases of the cardiac cycle. IAS thickness and thinning might be an additional parameter to evaluate systolic atrial function particularly with regard to maintenance of synus rhythm after

  14. Efficacy and Safety of Atrial Fibrillation Ablation Using Remote Magnetic Navigation

    DEFF Research Database (Denmark)

    Jin, Q I; Pehrson, Steen; Jacobsen, Peter Karl

    2016-01-01

    .0 minutes, PerAF, P = 0.17). The overall complication rate was 0.6%. One PAF patient experienced cardiac tamponade. AF repeat ablations by RMN significantly reduced the procedural and ablation times when compared with their first ablation times. CONCLUSIONS: AF ablation guided by RMN is safe as evidenced...

  15. Emergency bypass post percutaneous atrial ablation: a case report.

    LENUS (Irish Health Repository)

    Hargrove, M

    2010-11-01

    A 34-year-old male undergoing percutaneous atrial ablation procedure for paroxysmal fibrillation required emergency sternotomy for cardiac tamponade. The patient had been anticoagulated and had received plavix and aspirin prior to and during the ablation procedure. Seven units of red cell concentrate had been transfused in the cardiac catherisation laboratory. On arrival in theatre, the patient was hypotensive, but was awake on induction of anaesthesia. No recordable blood pressure with non-invasive monitoring was observed. A sternotomy was immediately performed and, on evacuation of the pericardium, a bleeding site was not visible. The patient was commenced on cardiopulmonary bypass. Bleeding site was identified and the defect closed. The patient was weaned from cardiopulmonary bypass with minimal inotropic support and made an uneventful recovery. Bypass time was 38 minutes. A literature review showed a 1% incidence of post-ablation bleeding(1). The incidence of reverting to bypass for such an event has not been reported previously. During these procedures, it might be wise to have the cardiothoracic team notified while atrial ablation procedures are being performed in the cardiac catheterization laboratory.

  16. Enhanced Radiofrequency Ablation With Magnetically Directed Metallic Nanoparticles.

    Science.gov (United States)

    Nguyen, Duy T; Tzou, Wendy S; Zheng, Lijun; Barham, Waseem; Schuller, Joseph L; Shillinglaw, Benjamin; Quaife, Robert A; Sauer, William H

    2016-05-01

    Remote heating of metal located near a radiofrequency ablation source has been previously demonstrated. Therefore, ablation of cardiac tissue treated with metallic nanoparticles may improve local radiofrequency heating and lead to larger ablation lesions. We sought to evaluate the effect of magnetic nanoparticles on tissue sensitivity to radiofrequency energy. Ablation was performed using an ablation catheter positioned with 10 g of force over prepared ex vivo specimens. Tissue temperatures were measured and lesion volumes were acquired. An in vivo porcine thigh model was used to study systemically delivered magnetically guided iron oxide (FeO) nanoparticles during radiofrequency application. Magnetic resonance imaging and histological staining of ablated tissue were subsequently performed as a part of ablation lesion analysis. Ablation of ex vivo myocardial tissue treated with metallic nanoparticles resulted in significantly larger lesions with greater impedance changes and evidence of increased thermal conductivity within the tissue. Magnet-guided localization of FeO nanoparticles within porcine thigh preps was demonstrated by magnetic resonance imaging and iron staining. Irrigated ablation in the regions with greater FeO, after FeO infusion and magnetic guidance, created larger lesions without a greater incidence of steam pops. Metal nanoparticle infiltration resulted in significantly larger ablation lesions with altered electric and thermal conductivity. In vivo magnetic guidance of FeO nanoparticles allowed for facilitated radiofrequency ablation without direct infiltration into the targeted tissue. Further research is needed to assess the clinical applicability of this ablation strategy using metallic nanoparticles for the treatment of cardiac arrhythmias. © 2016 American Heart Association, Inc.

  17. Use of bipolar radiofrequency catheter ablation in treatment of cardiac arrhythmias.

    Science.gov (United States)

    Soucek, Filip; Starek, Zdenek

    2018-05-23

    Background Arrhythmia management is a complex process involving both pharmacological and non-pharmacological approaches. Radiofrequency ablation is the pillar of non-pharmacological arrhythmia treatment. Unipolar ablation is considered to be the gold standard in the treatment of the majority of arrhythmias; however, its efficacy is limited to specific cases. In particular, the creation of deep or transmural lesions to eliminate intramurally originating arrhythmias remains inadequate. Bipolar ablation is proposed as an alternative to overcome unipolar ablation boundaries. Results Despite promising results gained from in vitro and animal studies showing that bipolar ablation is superior in creating transmural lesions, the use of bipolar ablation in daily clinical practice is limited. Several studies have been published showing that bipolar ablation is effective in the treatment of clinical arrhythmias after failed unipolar ablation, however there is inconsistency regarding safety of bipolar ablation within the available research papers. According to research evidence the most common indications for bipolar ablation use are ventricular originating rhythmic disorders in patients with structural heart disease resistant to standard radiofrequency ablation. Conclusions To allow wider clinical application the efficiency and safety of bipolar ablation need to be verified in future studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. Cardiac leiomyosarcoma, a case report

    DEFF Research Database (Denmark)

    Andersen, Rikke; Kristensen, Bjarne W; Gill, Sabine

    2013-01-01

    In this case report we present the history of a patient admitted with recurrent pulmonary edema. Transesophageal chocardiography showed a tumour in the left atrium, occluding the ostium of the mitral valve and mimicking intermittent mitral stenosis. Cardiac surgery followed by pathological...... examination revealed that the tumour was a leiomyosarcoma. Images from the echocardiography as well as the pathological findings are shown and discussed. The present case report illustrates that atrial tumors comprise also sarcomas, suggesting the use of careful, rapid diagnostic procedures and treatment...

  19. Adrenergic innervation of the developing chick heart: neural crest ablations to produce sympathetically aneural hearts

    International Nuclear Information System (INIS)

    Kirby, M.; Stewart, D.

    1984-01-01

    Ablation of various regions of premigratory trunk neural crest which gives rise to the sympathetic trunks was used to remove sympathetic cardiac innervation. Neuronal uptake of [ 3 H]-norepinephrine was used as an index of neuronal development in the chick atrium. Following ablation of neural crest over somites 10-15 or 15-20, uptake was significantly decreased in the atrium at 16 and 17 days of development. Ablation of neural crest over somites 5-10 and 20-25 caused no decrease in [ 3 H]-norepinephrine uptake. Removal of neural crest over somites 5-25 or 10-20 caused approximately equal depletions of [ 3 H]-norepinephrine uptake in the atrium. Cardiac norepinephrine concentration was significantly depressed following ablation of neural crest over somites 5-25 but not over somites 10-20. Light-microscopic and histofluorescent preparations confirmed the absence of sympathetic trunks in the region of the normal origin of the sympathetic cardiac nerves following neural crest ablation over somites 10-20. The neural tube and dorsal root ganglia were damaged in the area of the neural-crest ablation; however, all of these structures were normal cranial and caudal to the lesioned area. Development of most of the embryos as well as the morphology of all of the hearts was normal following the lesion. These results indicate that it is possible to produce sympathetically aneural hearts by neural-crest ablation; however, sympathetic cardiac nerves account for an insignificant amount of cardiac norepinephrine

  20. Anatomical Basis for the Cardiac Interventional Electrophysiologist

    Directory of Open Access Journals (Sweden)

    Damián Sánchez-Quintana

    2015-01-01

    Full Text Available The establishment of radiofrequency catheter ablation techniques as the mainstay in the treatment of tachycardia has renewed new interest in cardiac anatomy. The interventional arrhythmologist has drawn attention not only to the gross anatomic details of the heart but also to architectural and histological characteristics of various cardiac regions that are relevant to the development or recurrence of tachyarrhythmias and procedural related complications of catheter ablation. In this review, therefore, we discuss some anatomic landmarks commonly used in catheter ablations including the terminal crest, sinus node region, Koch’s triangle, cavotricuspid isthmus, Eustachian ridge and valve, pulmonary venous orifices, venoatrial junctions, and ventricular outflow tracts. We also discuss the anatomical features of important structures in the vicinity of the atria and pulmonary veins, such as the esophagus and phrenic nerves. This paper provides basic anatomic information to improve understanding of the mapping and ablative procedures for cardiac interventional electrophysiologists.

  1. Action Potential Shortening and Impairment of Cardiac Function by Ablation of Slc26a6.

    Science.gov (United States)

    Sirish, Padmini; Ledford, Hannah A; Timofeyev, Valeriy; Thai, Phung N; Ren, Lu; Kim, Hyo Jeong; Park, Seojin; Lee, Jeong Han; Dai, Gu; Moshref, Maryam; Sihn, Choong-Ryoul; Chen, Wei Chun; Timofeyeva, Maria Valeryevna; Jian, Zhong; Shimkunas, Rafael; Izu, Leighton T; Chiamvimonvat, Nipavan; Chen-Izu, Ye; Yamoah, Ebenezer N; Zhang, Xiao-Dong

    2017-10-01

    Intracellular pH (pH i ) is critical to cardiac excitation and contraction; uncompensated changes in pH i impair cardiac function and trigger arrhythmia. Several ion transporters participate in cardiac pH i regulation. Our previous studies identified several isoforms of a solute carrier Slc26a6 to be highly expressed in cardiomyocytes. We show that Slc26a6 mediates electrogenic Cl - /HCO 3 - exchange activities in cardiomyocytes, suggesting the potential role of Slc26a6 in regulation of not only pH i , but also cardiac excitability. To test the mechanistic role of Slc26a6 in the heart, we took advantage of Slc26a6 knockout ( Slc26a6 -/ - ) mice using both in vivo and in vitro analyses. Consistent with our prediction of its electrogenic activities, ablation of Slc26a6 results in action potential shortening. There are reduced Ca 2+ transient and sarcoplasmic reticulum Ca 2+ load, together with decreased sarcomere shortening in Slc26a6 -/ - cardiomyocytes. These abnormalities translate into reduced fractional shortening and cardiac contractility at the in vivo level. Additionally, pH i is elevated in Slc26a6 -/ - cardiomyocytes with slower recovery kinetics from intracellular alkalization, consistent with the Cl - /HCO 3 - exchange activities of Slc26a6. Moreover, Slc26a6 -/ - mice show evidence of sinus bradycardia and fragmented QRS complex, supporting the critical role of Slc26a6 in cardiac conduction system. Our study provides mechanistic insights into Slc26a6, a unique cardiac electrogenic Cl - /HCO 3 - transporter in ventricular myocytes, linking the critical roles of Slc26a6 in regulation of pH i , excitability, and contractility. pH i is a critical regulator of other membrane and contractile proteins. Future studies are needed to investigate possible changes in these proteins in Slc26a6 -/ - mice. © 2017 American Heart Association, Inc.

  2. Effects of local cardiac denervation on cardiac innervation and ventricular arrhythmia after chronic myocardial infarction.

    Directory of Open Access Journals (Sweden)

    Xudong Liu

    Full Text Available Modulation of the autonomic nervous system (ANS has already been demonstrated to display antiarrhythmic effects in patients and animals with MI. In this study, we investigated whether local cardiac denervation has any beneficial effects on ventricular electrical stability and cardiac function in the chronic phase of MI.Twenty-one anesthetized dogs were randomly assigned into the sham-operated, MI and MI-ablation groups, respectively. Four weeks after local cardiac denervation, LSG stimulation was used to induce VPCs and VAs. The ventricular fibrillation threshold (VFT and the incidence of inducible VPCs were measured with electrophysiological protocol. Cardiac innervation was determined with immunohistochemical staining of growth associated protein-43 (GAP43 and tyrosine hydroxylase (TH. The global cardiac and regional ventricular function was evaluated with doppler echocardiography in this study.Four weeks after operation, the incidence of inducible VPC and VF in MI-ablation group were significantly reduced compared to the MI dogs (p<0.05. Moreover, local cardiac denervation significantly improved VFT in the infarcted border zone (p<0.05. The densities of GAP43 and TH-positive nerve fibers in the infarcted border zone in the MI-ablation group were lower than those in the MI group (p<0.05. However, the local cardiac denervation did not significantly improve cardiac function in the chronic phase of MI, determined by the left ventricle diameter (LV, left atrial diameter (LA, ejection fraction (EF.Summarily, in the chronic phase of MI, local cardiac denervation reduces the ventricular electrical instability, and attenuates spatial heterogeneity of sympathetic nerve reconstruction. Our study suggests that this methodology might decrease malignant ventricular arrhythmia in chronic MI, and has a great potential for clinical application.

  3. Ventricular fibrillation occurring after atrioventricular node ablation despite minimal difference between pre- and post-ablation heart rates.

    Science.gov (United States)

    Squara, F; Theodore, G; Scarlatti, D; Ferrari, E

    2017-02-01

    We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  4. Intraoperative transesophageal echocardiography in congenital heart diseases surgery

    International Nuclear Information System (INIS)

    Ozores Suarez, Francisco Javier; Perez de Ordaz, Luis Bravo

    2010-01-01

    The intraoperative transesophageal echocardiography is very used in pediatric cardiovascular surgery. The aim of present paper was to determine its impact on the surgery immediate results after a previous experience of authors with this type of procedure

  5. Multimodality imaging to guide cardiac interventional procedures

    NARCIS (Netherlands)

    Tops, Laurens Franciscus

    2010-01-01

    In recent years, a number of new cardiac interventional procedures have been introduced. Catheter ablation procedures for atrial fibrillation (AF) have been refined and are now considered a good treatment option in patients with drug-refractory AF. In cardiac pacing, cardiac resynchronization

  6. Endocardial left ventricle feature tracking and reconstruction from tri-plane trans-esophageal echocardiography data

    Science.gov (United States)

    Dangi, Shusil; Ben-Zikri, Yehuda K.; Cahill, Nathan; Schwarz, Karl Q.; Linte, Cristian A.

    2015-03-01

    Two-dimensional (2D) ultrasound (US) has been the clinical standard for over two decades for monitoring and assessing cardiac function and providing support via intra-operative visualization and guidance for minimally invasive cardiac interventions. Developments in three-dimensional (3D) image acquisition and transducer design and technology have revolutionized echocardiography imaging enabling both real-time 3D trans-esophageal and intra-cardiac image acquisition. However, in most cases the clinicians do not access the entire 3D image volume when analyzing the data, rather they focus on several key views that render the cardiac anatomy of interest during the US imaging exam. This approach enables image acquisition at a much higher spatial and temporal resolution. Two such common approaches are the bi-plane and tri-plane data acquisition protocols; as their name states, the former comprises two orthogonal image views, while the latter depicts the cardiac anatomy based on three co-axially intersecting views spaced at 600 to one another. Since cardiac anatomy is continuously changing, the intra-operative anatomy depicted using real-time US imaging also needs to be updated by tracking the key features of interest and endocardial left ventricle (LV) boundaries. Therefore, rapid automatic feature tracking in US images is critical for three reasons: 1) to perform cardiac function assessment; 2) to identify location of surgical targets for accurate tool to target navigation and on-target instrument positioning; and 3) to enable pre- to intra-op image registration as a means to fuse pre-op CT or MR images used during planning with intra-operative images for enhanced guidance. In this paper we utilize monogenic filtering, graph-cut based segmentation and robust spline smoothing in a combined work flow to process the acquired tri-plane TEE time series US images and demonstrate robust and accurate tracking of the LV endocardial features. We reconstruct the endocardial LV

  7. Where does the pulmonary artery catheter float: Transesophageal echocardiography evaluation

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2015-01-01

    Full Text Available Background: Pulmonary artery (PA catheter provides a variety of cardiac and hemodynamic parameters. In majority of the patients, the catheter tends to float in the right pulmonary artery (RPA than the left pulmonary artery (LPA. We evaluated the location of PA catheter with the help of transesophageal echocardiography (TEE to know the incidence of its localization. Three views were utilized for this purpose; midesophageal ascending aorta (AA short-axis view, modified mid esophageal aortic valve long-axis view, and modified bicaval view. Methods: We enrolled 135 patients undergoing elective cardiac surgery where both the PA catheter and TEE were to be used; for this prospective observational study. PA catheter was visualized by TEE in the above mentioned views and the degree of clarity of visualization by three views was also noted. Position of the PA catheter was further confirmed by a postoperative chest radiograph. Results: One patient was excluded from the data analysis. PA catheter was visualized in RPA in 129 patients (96% and in LPA in 4 patients (3%. In 1 patient, the catheter was visualized in main PA in the chest radiograph. The midesophageal AA short-axis, modified aortic valve long-axis, and modified bicaval view provided good visualization in 51.45%, 57.4%, and 62.3% patients respectively. Taken together, PA catheter visualization was good in 128 (95.5% patients. Conclusion: We conclude that the PA catheter has a high probability of entering the RPA as compared to LPA (96% vs. 3% and TEE provides good visualization of the catheter in RPA.

  8. Complications associated with radiofrequency ablation of pulmonary veins.

    Science.gov (United States)

    Madrid Pérez, J M; García Barquín, P M; Villanueva Marcos, A J; García Bolao, J I; Bastarrika Alemañ, G

    Radiofrequency ablation is an efficacious alternative in patients with symptomatic atrial fibrillation who do not respond to or are intolerant to at least one class I or class III antiarrhythmic drug. Although radiofrequency ablation is a safe procedure, complications can occur. Depending on the location, these complications can be classified into those that affect the pulmonary veins themselves, cardiac complications, extracardiac intrathoracic complications, remote complications, and those that result from vascular access. The most common complications are hematomas, arteriovenous fistulas, and pseudoaneurysms at the puncture site. Some complications are benign and transient, such as gastroparesis or diaphragmatic elevation, whereas others are potentially fatal, such as cardiac tamponade. Radiologists must be familiar with the complications that can occur secondary to pulmonary vein ablation to ensure early diagnosis and treatment. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Novel System for Real-Time Integration of 3-D Echocardiography and Fluoroscopy for Image-Guided Cardiac Interventions: Preclinical Validation and Clinical Feasibility Evaluation

    Science.gov (United States)

    Housden, R. James; Ma, Yingliang; Rajani, Ronak; Gao, Gang; Nijhof, Niels; Cathier, Pascal; Bullens, Roland; Gijsbers, Geert; Parish, Victoria; Kapetanakis, Stamatis; Hancock, Jane; Rinaldi, C. Aldo; Cooklin, Michael; Gill, Jaswinder; Thomas, Martyn; O'neill, Mark D.; Razavi, Reza; Rhode, Kawal S.

    2014-01-01

    Real-time imaging is required to guide minimally invasive catheter-based cardiac interventions. While transesophageal echocardiography allows for high-quality visualization of cardiac anatomy, X-ray fluoroscopy provides excellent visualization of devices. We have developed a novel image fusion system that allows real-time integration of 3-D echocardiography and the X-ray fluoroscopy. The system was validated in the following two stages: 1) preclinical to determine function and validate accuracy; and 2) in the clinical setting to assess clinical workflow feasibility and determine overall system accuracy. In the preclinical phase, the system was assessed using both phantom and porcine experimental studies. Median 2-D projection errors of 4.5 and 3.3 mm were found for the phantom and porcine studies, respectively. The clinical phase focused on extending the use of the system to interventions in patients undergoing either atrial fibrillation catheter ablation (CA) or transcatheter aortic valve implantation (TAVI). Eleven patients were studied with nine in the CA group and two in the TAVI group. Successful real-time view synchronization was achieved in all cases with a calculated median distance error of 2.2 mm in the CA group and 3.4 mm in the TAVI group. A standard clinical workflow was established using the image fusion system. These pilot data confirm the technical feasibility of accurate real-time echo-fluoroscopic image overlay in clinical practice, which may be a useful adjunct for real-time guidance during interventional cardiac procedures. PMID:27170872

  10. Microwave Tissue Ablation: Biophysics, Technology and Applications

    Science.gov (United States)

    2010-01-01

    Microwave ablation is an emerging treatment option for many cancers, cardiac arrhythmias and other medical conditions. During treatment, microwaves are applied directly to tissues to produce rapid temperature elevations sufficient to produce immediate coagulative necrosis. The engineering design criteria for each application differ, with individual consideration for factors such as desired ablation zone size, treatment duration, and procedural invasiveness. Recent technological developments in applicator cooling, power control and system optimization for specific applications promise to increase the utilization of microwave ablation in the future. This article will review the basic biophysics of microwave tissue heating, provide an overview of the design and operation of current equipment, and outline areas for future research for microwave ablation. PMID:21175404

  11. Developing the Safety of Atrial Fibrillation Ablation Registry Initiative (SAFARI) as a collaborative pan-stakeholder critical path registry model: a Cardiac Safety Research Consortium "Incubator" Think Tank.

    Science.gov (United States)

    Al-Khatib, Sana M; Calkins, Hugh; Eloff, Benjamin C; Kowey, Peter; Hammill, Stephen C; Ellenbogen, Kenneth A; Marinac-Dabic, Danica; Waldo, Albert L; Brindis, Ralph G; Wilbur, David J; Jackman, Warren M; Yaross, Marcia S; Russo, Andrea M; Prystowsky, Eric; Varosy, Paul D; Gross, Thomas; Pinnow, Ellen; Turakhia, Mintu P; Krucoff, Mitchell W

    2010-10-01

    Although several randomized clinical trials have demonstrated the safety and efficacy of catheter ablation of atrial fibrillation (AF) in experienced centers, the outcomes of this procedure in routine clinical practice and in patients with persistent and long-standing persistent AF remain uncertain. Brisk adoption of this therapy by physicians with diverse training and experience highlights potential concerns regarding the safety and effectiveness of this procedure. Some of these concerns could be addressed by a national registry of AF ablation procedures such as the Safety of Atrial Fibrillation Ablation Registry Initiative that was initially proposed at a Cardiac Safety Research Consortium Think Tank meeting in April 2009. In January 2010, the Cardiac Safety Research Consortium, in collaboration with the Duke Clinical Research Institute, the US Food and Drug Administration, the American College of Cardiology, and the Heart Rhythm Society, held a follow-up meeting of experts in the field to review the construct and progress to date. Other participants included the National Heart, Lung, and Blood Institute; the Centers for Medicare and Medicaid Services; the Agency for Healthcare Research and Quality; the AdvaMed AF working group; and additional industry representatives. This article summarizes the discussions that occurred at the meeting of the state of the Safety of Atrial Fibrillation Ablation Registry Initiative, the identification of a clear pathway for its implementation, and the exploration of solutions to potential issues in the execution of this registry. Copyright © 2010 Mosby, Inc. All rights reserved.

  12. Intra-cardiac echocardiography in alcohol septal ablation

    DEFF Research Database (Denmark)

    Cooper, Robert M; Shahzad, Adeel; Newton, James

    2015-01-01

    Alcohol septal ablation (ASA) in hypertrophic obstructive cardiomyopathy reduces left ventricular outflow tract gradients. A third of patients do not respond; inaccurate localisation of the iatrogenic infarct can be responsible. Transthoracic echocardiography (TTE) using myocardial contrast can...

  13. [Peculiarities of the transesophageal echocardiography in octogenarian patients].

    Science.gov (United States)

    Canale, Jesús M; Cardoza-Encinas, Rubén; Canale-Segovia, Andrés

    The growing trend in the absolute and relative number of elderly in the population scheme, the increasing prevalence of heart disease as people get older and the impressive technological development of ultrasound devices have all together recently contributed to promote an increasing number of transesophageal echocardiograms in older patients, however, the already published information about the distinguishing features of this diagnostic methodology in elderly patients is still scarce and seems to be insufficient. This review focuses on the already published methodological and diagnostic features related to the transesophageal echocardiography in the octogenarian -or even older patient- in order to show them in an orderly and systematic manner to provide elements that induce useful clinical criteria for the physician who attends patients in this age group in whom this diagnostic modality is now increasingly requested. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  14. The effect of transesophageal echocardiography in the surgical treatment of tetralogy of Fallot.

    Science.gov (United States)

    Wang, L-C; Li, S-K; Zhu, F-T; Bian, T; Wang, H-Y

    2018-04-01

    To investigate the effect of transesophageal echocardiography (TEE) in the surgical treatment of tetralogy of Fallot. 98 patients with tetralogy of Fallot received and cured by Zhengzhou Cardiovascular Hospital (Zhengzhou No. 7 People's Hospital) from January 2015 to January 2017 were selected as the study objects. All patients were examined by TEE before surgery, and the pulmonary artery index (PAI) and pulmonary vein index (PVI) were measured, so as to analyze the effect of TEE in the surgical treatment of tetralogy of Fallot. Among the 98 patients, 12 patients were diagnosed with intensive care unit (ICU) retention, 23 patients were diagnosed with respirator assisted respiration extension, 8 patients were diagnosed with low cardiac output syndrome, and 10 patients were diagnosed with respiratory tract infection, which indicated that TEE could diagnose conditions after radical operation of tetralogy of Fallot. The calculation results showed that the PAI was (171.37±58.39) mm2/m2 and the PVI was (282.46±54.37) mm2/m2. The Pearson correlation analysis showed that the correlation between them was good (r=0.821, ptetralogy of Fallot. TEE can predict the occurrence of respirator assisted respiration extension, ICU retention and low cardiac output syndrome of patients after radical surgery by evaluating the PAI and PVI of patients with tetralogy of Fallot.

  15. An efficient cardiac mapping strategy for radiofrequency catheter ablation with active learning.

    Science.gov (United States)

    Feng, Yingjing; Guo, Ziyan; Dong, Ziyang; Zhou, Xiao-Yun; Kwok, Ka-Wai; Ernst, Sabine; Lee, Su-Lin

    2017-07-01

    A major challenge in radiofrequency catheter ablation procedures is the voltage and activation mapping of the endocardium, given a limited mapping time. By learning from expert interventional electrophysiologists (operators), while also making use of an active-learning framework, guidance on performing cardiac voltage mapping can be provided to novice operators or even directly to catheter robots. A learning from demonstration (LfD) framework, based upon previous cardiac mapping procedures performed by an expert operator, in conjunction with Gaussian process (GP) model-based active learning, was developed to efficiently perform voltage mapping over right ventricles (RV). The GP model was used to output the next best mapping point, while getting updated towards the underlying voltage data pattern as more mapping points are taken. A regularized particle filter was used to keep track of the kernel hyperparameter used by GP. The travel cost of the catheter tip was incorporated to produce time-efficient mapping sequences. The proposed strategy was validated on a simulated 2D grid mapping task, with leave-one-out experiments on 25 retrospective datasets, in an RV phantom using the Stereotaxis Niobe ® remote magnetic navigation system, and on a tele-operated catheter robot. In comparison with an existing geometry-based method, regression error was reduced and was minimized at a faster rate over retrospective procedure data. A new method of catheter mapping guidance has been proposed based on LfD and active learning. The proposed method provides real-time guidance for the procedure, as well as a live evaluation of mapping sufficiency.

  16. Theoretical and experimental analysis of amplitude control ablation and bipolar ablation in creating linear lesion and discrete lesions for treating atrial fibrillation.

    Science.gov (United States)

    Yan, Shengjie; Wu, Xiaomei; Wang, Weiqi

    2017-09-01

    Radiofrequency (RF) energy is often used to create a linear lesion or discrete lesions for blocking the accessory conduction pathways for treating atrial fibrillation. By using finite element analysis, we study the ablation effect of amplitude control ablation mode (AcM) and bipolar ablation mode (BiM) in creating a linear lesion and discrete lesions in a 5-mm-thick atrial wall; particularly, the characteristic of lesion shape has been investigated in amplitude control ablation. Computer models of multipolar catheter were developed to study the lesion dimensions in atrial walls created through AcM, BiM and special electrodes activated ablation methods in AcM and BiM. To validate the theoretical results in this study, an in vitro experiment with porcine cardiac tissue was performed. At 40 V/20 V root mean squared (RMS) of the RF voltage for AcM, the continuous and transmural lesion was created by AcM-15s, AcM-5s and AcM-ad-20V ablation in 5-mm-thick atrial wall. At 20 V RMS for BiM, the continuous but not transmural lesion was created. AcM ablation yielded asymmetrical and discrete lesions shape, whereas the lesion shape turned to more symmetrical and continuous as the electrodes alternative activated period decreased from 15 s to 5 s. Two discrete lesions were created when using AcM, AcM-ad-40V, BiM-ad-20V and BiM-ad-40V. The experimental and computational thermal lesion shapes created in cardiac tissue were in agreement. Amplitude control ablation technology and bipolar ablation technology are feasible methods to create continuous lesion or discrete for pulmonary veins isolation.

  17. Organizing Thrombus Mimicking a Cardiac Tumor Located at the Mitral-Aortic Intervalvular Fibrosa

    Directory of Open Access Journals (Sweden)

    Ji Seong Lee

    2016-02-01

    Full Text Available Thrombosis at the left ventricular outflow tract occurs without any detectable heart disease or predisposing factors only extremely rarely. A 48-year-old male visited Konkuk University Medical Center with loss of consciousness one month prior to presentation. Before he visited our hospital, he had been diagnosed with a cardiac tumor, which was located between the left atrium and posterior aortic root, and which was adjacent to both the aortic and mitral valves. Cardiac transplantation was recommended at the other hospital because of the high risk of cardiac dysfunction induced by both aortic and mitral valvular dysfunction after surgical resection. Based on preoperative transthoracic echocardiography, cardiac computed tomography, cardiac magnetic resonance imaging, and intraoperative transesophageal echocardiography, we considered it to be a benign tumor. Complete resection was achieved and the pathology confirmed organizing thrombus. We report a case of organizing thrombus mimicking a cardiac tumor, which was located at the mitral-aortic intervalvular fibrosa of the left ventricular outflow tract without any heart disease.

  18. Electroporation ablation: A new energy modality for ablation of arrhythmogenic cardiac substrate

    NARCIS (Netherlands)

    van Driel, VJHM

    2016-01-01

    At the very end of the Direct Current (DC) era, low-energy DC ablation was demonstrated to cause myocardial lesions by non-thermal irreversible electroporation (IRE) (permanent formation of pores in the cell membrane, leading to cell death), without arcing and/or barotrauma. To eliminate rather

  19. Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.

    Science.gov (United States)

    Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P

    1995-01-01

    Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.

  20. Natural history of severe atheromatous disease of the thoracic aorta: a transesophageal echocardiographic study.

    Science.gov (United States)

    Montgomery, D H; Ververis, J J; McGorisk, G; Frohwein, S; Martin, R P; Taylor, W R

    1996-01-01

    This study sought to prospectively observe the morphologic and clinical natural history of severe atherosclerotic disease of the thoracic aorta as defined by transesophageal echocardiography. Atherosclerosis of the thoracic aorta has been shown to be highly associated with risk for embolic events in transesophageal studies, but the natural history of the disease under clinical conditions has not been reported. During a 20-month period, 191 of 264 patients undergoing transesophageal echocardiography had adequate visualization of the aorta to allow atherosclerotic severity to be graded as follows: grade I = normal (44 patients); grade II = intimal thickening (52 patients); grade III = atheroma or = 5 mm (19 patients); grade V = mobile lesion (14 patients). All available patients with grades IV (8 patients) and V (10 patients) disease as well as a subgroup of 12 patients with grade III disease had follow-up transesophageal echocardiographic studies (mean [+/- SD] 11.7 +/- 0.9 months, range 6 to 22). Of 30 patients undergoing follow-up transesophageal echocardiographic studies, 20 (66%) had no change in atherosclerotic severity grade. Of the remaining 10 patients, atherosclerotic severity progressed one grade in 7 and decreased in 3 with resolved mobile lesions. Of 18 patients with grade IV or V disease of the aorta who underwent a follow-up study, 11 (61%) demonstrated formation of new mobile lesions. Of 10 patients with grade V disease on initial study who underwent follow-up study, 7 (70%) demonstrated resolution of a specific previously documented mobile lesion. However, seven patients (70%) with grade V disease also demonstrated development of a new mobile lesion. Of 33 patients with grade IV or V disease, 8 (24%) died during the study period, and 1 (3%) had a clinical embolic event. The presence of severe atherosclerotic disease of the thoracic aorta as defined by transesophageal echocardiography is associated with a high mortality rate. Although the morphologic

  1. Percutenous Catheter Ablation of the Accessory Pathway in a Patient with Wolff-Parkinson-White Syndrome Associated with Familial Atrial Fibrillation

    Science.gov (United States)

    Cay, Serkan; Topaloglu, Serkan; Aras, Dursun

    2008-01-01

    Percutenous catheter ablation of the accessory pathway in Wolff-Parkinson-White syndrome is a highly successful mode of therapy. Sudden cardiac arrest survivors associated with WPW syndrome should undergo radiofrequency catheter ablation. WPW syndrome associated with familial atrial fibrillation is a very rare condition. Herein, we describe a case who presented with sudden cardiac arrest secondary to WPW syndrome and familial atrial fibrillation and treated via radiofrequency catheter ablation. PMID:18379660

  2. Patient perspectives of participating in the cardiac CopenHeartRFA rehabilitation program for patients treated with ablation for atrial fibrillation

    DEFF Research Database (Denmark)

    Risom, Signe Stelling; Lind, Johanne; J McCabe, Pamela

    2018-01-01

    . As part of the evaluation of the CopenHeartRFA trial, both quantitative and qualitative data were collected. The intervention was delivered by a multidisciplinary team. Aim: This study aimed to understand the experience of patients treated for AF with ablation who participated in the CopenHeartRFA cardiac....... The interviews were analyzed individually by two researchers and themes were constructed and discussed. Results: The sample included 10 participants, mean age 54.6 years. Four categories were identified and labeled: 1) strengthening belief in one’s own physical capacity and survival; 2) still struggling...

  3. Persistent Visual Aura following Catheter Ablation in a Patient with WPW Syndrome

    Directory of Open Access Journals (Sweden)

    Shinichi Koyama

    2007-01-01

    Full Text Available We report a patient who has had persistent visual disturbances since she underwent catheter ablation to treat her Wolff-Parkinson-White (WPW syndrome. We examined her visual symptoms carefully and quantitatively by means of our newly developed method combining image-processing and psychophysics. We first simulated the patient’s visual symptoms using image-processing techniques. Since the simulation indicated that she would be very sensitive to the edges of the visual stimuli, we evaluated her sensitivity to the edges using psychophysics. The results indicated that she was hypersensitive to the clear-cut edges of the visual stimuli. Her visual symptoms were very similar to those of visual aura of migraine, rather than those of photosensitive epilepsy. Magnetic resonance imaging (MRI and single photon emission computed tomography (SPECT, electroenchepalogram (EEG, and visual-evoked potentials (VEP in the patient were normal. No abnormalities in her fundus, visual field, or electroretinogram were found, either. Transesophageal echocardiography with bubble study indicated that she had a preexisting right-to-left shunt. We hypothesize that visual aura of migraine was triggered and made persistent by the catheter ablation in this patient. Although the relationship between migraine, catheter ablation, and right-to-left shunts is unknown, previous studies on the transcatheter closure of patent foramen ovale suggest a possible link between them. Catheter ablation in patients with migraine and preexisting shunts may lead to exacerbations in migraine symptoms.

  4. Percutenous Catheter Ablation of the Accessory Pathway in a Patient with Wolff-Parkinson-White Syndrome Associated with Familial Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Serkan Cay

    2008-04-01

    Full Text Available Percutenous catheter ablation of the accessory pathway in Wolff-Parkinson-White syndrome is a highly successful mode of therapy. Sudden cardiac arrest survivors associated with WPW syndrome should undergo radiofrequency catheter ablation. WPW syndrome associated with familial atrial fibrillation is a very rare condition. Herein, we describe a case who presented with sudden cardiac arrest secondary to WPW syndrome and familial atrial fibrillation and treated via radiofrequency catheter ablation.

  5. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    Science.gov (United States)

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  6. CT imaging of complications of catheter ablation for atrial fibrillation

    International Nuclear Information System (INIS)

    Shroff, G.S.; Guirguis, M.S.; Ferguson, E.C.; Oldham, S.A.A.; Kantharia, B.K.

    2014-01-01

    The complication rate following radiofrequency catheter ablation for atrial fibrillation is low (<5%). Complications include pericardial effusion, cardiac tamponade, pulmonary vein stenosis, oesophageal ulceration or perforation, atrio-oesophageal fistula formation, stroke/transient ischaemic attack, phrenic nerve injury, haematoma at the puncture site, and femoral arteriovenous fistula. Among available imaging tools, computed tomography (CT) can be very useful in diagnosing complications of the procedure, particularly in the subacute and delayed stages after ablation. This review illustrates CT imaging of several of the common and uncommon complications of radiofrequency catheter ablation

  7. Incremental benefit of 3D transesophageal echocardiography: a case of a mass overlying a prosthetic mitral valve.

    Science.gov (United States)

    Tauras, James M; Zhang, Zhihang; Taub, Cynthia C

    2011-05-01

    A young woman with a mechanical mitral valve and prosthetic mitral stenosis underwent multiple imaging modalities (including transthoracic ECHO, fluoroscopy, and two-dimensional transesophageal ECHO) to determine the cause of her stenosis. Only three-dimensional transesophageal echocardiography demonstrated the full size and extent of an obstructing mass on the strut and sewing ring of the prosthetic mitral valve. © 2011, Wiley Periodicals, Inc.

  8. Multiplanar transesophageal echocardiography for the evaluation and percutaneous management of ostium secundum atrial septal defects in the adult.

    Science.gov (United States)

    Sobrino, Ayax; Basmadjian, Arsène J; Ducharme, Anique; Ibrahim, Reda; Mercier, Lise-Andrée; Pelletier, Guy B; Marcotte, François; Garceau, Patrick; Burelle, Denis; O'Meara, Eileen; Dore, Annie

    2012-01-01

    The purpose of this paper is to review the usefulness of multiplanar transesophageal echocardiography before, during and after percutaneous transcatheter closure of secundum atrial septal defects. Transesophageal echocardiography imaging techniques,including their role in patient selection, procedural guidance and immediate assessment of technical success and complications are described and discussed in this review. Percutaneous transcatheter closure is indicated for ostium secundum atrial septal defects of less than 40 mm in maximal diameter. The defect must have a favorable anatomy, with adequate rims of at least 5 mm to anchor the prosthesis. Transesophageal echocardiography plays a critical role before the procedure in identifying potential candidates for percutaneous closure and to exclude those with unfavorable anatomy or associated lesions, which could not be addressed percutaneously. Transesophageal echocardiography is also important during the procedure to guide the deployment of the device. After device deployment, the echocardiographer must assess the device (integrity, position and stability), residual shunt, atrio-ventricular valve regurgitation, obstruction to systemic or venous return and pericardial effusion, in order to determine procedural success and diagnose immediate complications.

  9. Percutaneous Irreversible Electroporation Lung Ablation: Preliminary Results in a Porcine Model

    International Nuclear Information System (INIS)

    Deodhar, Ajita; Monette, Sébastien; Single, Gordon W.; Hamilton, William C.; Thornton, Raymond H.; Sofocleous, Constantinos T.; Maybody, Majid; Solomon, Stephen B.

    2011-01-01

    Objective: Irreversible electroporation (IRE) uses direct electrical pulses to create permanent “pores” in cell membranes to cause cell death. In contrast to conventional modalities, IRE has a nonthermal mechanism of action. Our objective was to study the histopathological and imaging features of IRE in normal swine lung. Materials and Methods: Eleven female swine were studied for hyperacute (8 h), acute (24 h), subacute (96 h), and chronic (3 week) effects of IRE ablation in lung. Paired unipolar IRE applicators were placed under computed tomography (CT) guidance. Some applicators were deliberately positioned near bronchovascular structures. IRE pulse delivery was synchronized with the cardiac rhythm only when ablation was performed within 2 cm of the heart. Contrast-enhanced CT scan was performed immediately before and after IRE and at 1 and 3 weeks after IRE ablation. Representative tissue was stained with hematoxylin and eosin for histopathology. Results: Twenty-five ablations were created: ten hyperacute, four acute, and three subacute ablations showed alveolar edema and necrosis with necrosis of bronchial, bronchiolar, and vascular epithelium. Bronchovascular architecture was maintained. Chronic ablations showed bronchiolitis obliterans and alveolar interstitial fibrosis. Immediate post-procedure CT images showed linear or patchy density along the applicator tract. At 1 week, there was consolidation that resolved partially or completely by 3 weeks. Pneumothorax requiring chest tube developed in two animals; no significant cardiac arrhythmias were noted. Conclusion: Our preliminary porcine study demonstrates the nonthermal and extracellular matrix sparing mechanism of action of IRE. IRE is a potential alternative to thermal ablative modalities.

  10. Prolonged action potential duration in cardiac ablation of PDK1 mice.

    Science.gov (United States)

    Han, Zhonglin; Jiang, Yu; Yang, Zhongzhou; Cao, Kejiang; Wang, Dao W

    2015-01-01

    The involvement of the AGC protein kinase family in regulating arrhythmia has drawn considerable attention, but the underlying mechanisms are still not clear. The aim of this study is to explore the role of 3-phosphoinositide-dependent protein kinase-1 (PDK1), one of upstream protein kinases of the AGC protein kinase family, in the pathogenesis of dysregulated electrophysiological basis. PDK1(F/F) αMHC-Cre mice and PDK1(F/F) mice were divided into experiment group and control group. Using patch clamping technology, we explored action potential duration in both groups, and investigated the functions of transient outward potassium channel and L-type Ca(2+) channel to explain the abnormal action potential duration. Significant prolongation action potential duration was found in mice with PDK1 deletion. Further, the peak current of transient outward potassium current and L-type Ca(2+) current were decreased by 84% and 49% respectively. In addition, dysregulation of channel kinetics lead to action potential duration prolongation further. In conclusion, we have demonstrated that PDK1 participates in action potential prolongation in cardiac ablation of PDK1 mice. This effect is likely to be mediated largely through downregulation of transient outward potassium current. These findings indicate the modulation of the PDK1 pathway could provide a new mechanism for abnormal electrophysiological basis.

  11. Catheter ablation of epicardial ventricular tachycardia

    Directory of Open Access Journals (Sweden)

    Takumi Yamada, MD, PhD

    2014-08-01

    Full Text Available Ventricular tachycardias (VTs can usually be treated by endocardial catheter ablation. However, some VTs can arise from the epicardial surface, and their substrate can be altered only by epicardial catheter ablation. There are two approaches to epicardial catheter ablation: transvenous and transthoracic. The transvenous approach through the coronary venous system (CVS has been commonly used because it is easily accessible. However, this approach may be limited by the distribution of the CVS and insufficient radiofrequency energy delivery. Transthoracic epicardial catheter ablation has been developed to overcome these limitations of the transvenous approach. It is a useful supplemental or even preferred strategy to eliminate epicardial VTs in the electrophysiology laboratory. This technique has been applied for scar-related VTs secondary to often non-ischemic cardiomyopathy and sometimes ischemic cardiomyopathy, and idiopathic VTs as the epicardial substrates of these VTs have become increasingly recognized. When endocardial ablation and epicardial ablation through the CVS are unsuccessful, transthoracic epicardial ablation should be the next option. Intrapericardial access is usually obtained through a subxiphoidal pericardial puncture. This approach might not be possible in patients with pericardial adhesions caused by prior cardiac surgery or pericarditis. In such cases, a hybrid procedure involving surgical access with a subxiphoid pericardial window and a limited anterior or lateral thoracotomy might be a feasible and safe method of performing an epicardial catheter ablation in the electrophysiology laboratory. Potential complications associated with this technique include bleeding and collateral damage to the coronary arteries and phrenic nerve. Although the risk of these complications is low, electrophysiologists who attempt epicardial catheter ablation should know the complications associated with this technique, how to minimize their

  12. Anesthesia for robotic cardiac surgery: An amalgam of technology and skill

    Directory of Open Access Journals (Sweden)

    Chauhan Sandeep

    2010-01-01

    Full Text Available The surgical procedures performed with robtic assitance and the scope for its future assistance is endless. To keep pace with the developing technologies in this field it is imperative for the cardiac anesthesiologists to have aworking knowledge of these systems, recognize potential complications and formulate an anesthetic plan to provide safe patient care. Challenges posed by the use of robotic systems include, long surgical times, problems with one lung anesthesia in presence of coronary artery disease, minimally invasive percutaneous cardiopulmonary bypass management and expertise in Trans-Esophageal Echocardiography. A long list of cardiac surgeries are performed with the use of robotic assistance, and the list is continuously growing as surgical innovation crosses new boundaries. Current research in robotic cardiac surgery like beating heart off pump intracardic repair, prototype epicardial crawling device, robotic fetal techniques etc. are in the stage of animal experimentation, but holds a lot of promise in future

  13. Segmentation of multiple heart cavities in 3-D transesophageal ultrasound images

    NARCIS (Netherlands)

    Haak, A.; Vegas-Sanchez-Ferrero, G.; Mulder, H.W.; Ren, B.; Kirisli, H.A.; Metz, C.; van Burken, G.; van Stralen, M.; Pluim, J.P.W.; Steen, van der A.F.W.; Walsum, van T.; Bosch, J.G.

    Three-dimensional transesophageal echocardiography (TEE) is an excellent modality for real-time visualization of the heart and monitoring of interventions. To improve the usability of 3-D TEE for intervention monitoring and catheter guidance, automated segmentation is desired. However, 3-D TEE

  14. The use of echocardiography in Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Cai, Qiangjun; Shuraih, Mossaab; Nagueh, Sherif F

    2012-04-01

    Endocardial mapping and radiofrequency catheter ablation are well established modalities for the diagnosis and treatment of patients with Wolff-Parkinson-White (WPW) syndrome associated with tachyarrhythmias. However, the electrophysiologic techniques are invasive, require radiation exposure, and lack spatial resolution of cardiac structures. A variety of echocardiographic techniques have been investigated as a non-invasive alternative for accessory pathway localization. Conventional M-mode echocardiography can detect the fine premature wall motion abnormalities associated with WPW syndrome. However, it is unable to identify the exact site of accessory pathway with sufficient accuracy. 2D, 2D-guided M-mode, and 2D phase analysis techniques are limited by image quality and endocardial border definition. Various modalities of tissue Doppler echocardiography significantly increase the accuracy of left-sided accessory pathway localization to 80-90% even in patients with poor acoustic window. However, right-sided pathways remain a diagnostic challenge. Strain echocardiography by speckle tracking has recently been evaluated and appears promising. Different cardiac abnormalities have been detected by echocardiography in WPW patients. Patients with WPW syndrome and tachyarrhythmias have impaired systolic and diastolic function which improves after radiofrequency ablation. Echocardiography is useful in identifying patient with accessory pathway-associated left ventricular dyssynchrony and dysfunction who may benefit from ablation therapy. Transesophageal and intracardiac echocardiography have been used to guide ablation procedure. Ablation-related complications detected by routine echocardiography are infrequent, rarely clinically relevant, and of limited value.

  15. Assessment of inpatient multimodal cardiac imaging appropriateness at large academic medical centers.

    Science.gov (United States)

    Remfry, Andrew; Abrams, Howard; Dudzinski, David M; Weiner, Rory B; Bhatia, R Sacha

    2015-11-14

    Responding to concerns regarding the growth of cardiac testing, the American College of Cardiology Foundation (ACCF) published Appropriate Use Criteria (AUC) for various cardiac imaging modalities. Single modality cardiac imaging appropriateness has been reported but there have been no studies assessing the appropriateness of multiple imaging modalities in an inpatient environment. A retrospective study of the appropriateness of cardiac tests ordered by the inpatient General Internal Medicine (GIM) and Cardiology services at three Canadian academic hospitals was conducted over two one-month periods. Cardiac tests characterized were transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), single-photon emission tomography myocardial perfusion imaging (SPECT), and diagnostic cardiac catheterization. Overall, 553 tests were assessed, of which 99.8% were classifiable by AUC. 91% of all studies were categorized as appropriate, 4% may be appropriate and 5% were rarely appropriate. There were high rates of appropriate use of all modalities by GIM and Cardiology throughout. Significantly more appropriate diagnostic catheterizations were ordered by Cardiology than GIM (93% vs. 82%, p = imaging modalities in this multi-centered study on Cardiology and GIM inpatients in the acute care setting. The rate of appropriate ordering was high across all imaging modalities. We recommend further work towards improving appropriate utilization of cardiac imaging resources focus on the out-patient setting.

  16. The Heart of the Matter: Increasing Quality and Charge Capture from Intraoperative Transesophageal Echocardiography.

    Science.gov (United States)

    Sanford, Joseph A; Kadry, Bassam; Oakes, Daryl; Macario, Alex; Schmiesing, Cliff

    2016-04-15

    Although transesophageal echocardiography is routinely performed at our institution, there is no easy way to document the procedure in the electronic medical record and generate a bill compliant with reimbursement requirements. We present the results of a quality improvement project that used agile development methodology to incorporate intraoperative transesophageal echocardiography into the electronic medical record. We discuss improvements in the quality of clinical documentation, technical workflow challenges overcome, and cost and time to return on investment. Billing was increased from an average of 36% to 84.6% when compared with the same time period in the previous year. The expected recoupment of investment for this project is just 18 weeks.

  17. Measurement of Thrombus Flux Using Transesophageal Echocardiography

    Science.gov (United States)

    Yamaguchi, Tadashi; Hirai, Kazuki; Aoki, Masami; Miyagi, Jin; Suzuki, Masahiko; Moriya, Hideshige; Hachiya, Hiroyuki

    2006-05-01

    Deep venous thrombosis (DVT) and pulmonary thromboembolism (PTE) are serious problem of total knee replacement (TKR). These diseases may be caused by a thrombus formed during the TKR operation. Therefore, understanding the flow volume of thrombus is important for curing and preventing PTE. In this paper, we tried to understanding the situation of the flow of thrombus by using transesophageal echocardiography movies. We applied the signal processing technique the FSET to extract the anomalous information from ultrasonic echo image. As a result of processing, the time change of the flow volume of thrombus was confirmed.

  18. Surgical Ablation of Atrial Fibrillation Using Energy Sources.

    Science.gov (United States)

    Brick, Alexandre Visconti; Braile, Domingo Marcolino

    2015-01-01

    Surgical ablation, concomitant with other operations, is an option for treatment in patients with chronic atrial fibrillation. The aim of this study is to present a literature review on surgical ablation of atrial fibrillation in patients undergoing cardiac surgery, considering energy sources and return to sinus rhythm. A comprehensive survey was performed in the literature on surgical ablation of atrial fibrillation considering energy sources, sample size, study type, outcome (early and late), and return to sinus rhythm. Analyzing studies with immediate results (n=5), the percentage of return to sinus rhythm ranged from 73% to 96%, while those with long-term results (n=20) (from 12 months on) ranged from 62% to 97.7%. In both of them, there was subsequent clinical improvement of patients who underwent ablation, regardless of the energy source used. Surgical ablation of atrial fibrillation is essential for the treatment of this arrhythmia. With current technology, it may be minimally invasive, making it mandatory to perform a procedure in an attempt to revert to sinus rhythm in patients requiring heart surgery.

  19. Customized CT angiogram planning for intraoperative transesophageal echography-guided endovascular exclusion of thoracic aorta penetrating ulcer.

    Science.gov (United States)

    Piazza, Michele; Lupia, Mario; Grego, Franco; Antonello, Michele

    2015-04-01

    The technique is demonstrated in a 78-year-old man; the preoperative CT angiogram showed a descending thoracic aorta ulcer of 5.9 cm in maximum diameter and 3.8 cm longitudinal extension. A ZTEG-2P-36-127-PF (Cook Medical) single tubular endograft was planned to be deployed. From the preoperative CT angiogram we planned to land 4.7 cm above the midline of the descending thoracic aorta ulcer and 8.0 cm below. In the operating room, under radioscopic vision the centre of the transesophageal echography probe was used as marker to identify the correspondent midline of the descending thoracic aorta ulcer and a centimeter-sized pigtail catheter in the aorta was used to calculate the desired length above and below the ulcer midline. The endograft was introduced and placed in the desired position compared to the transesophageal echography probe and the catheter; under transesophageal echography vision the graft was finally deployed. The CT angiogram at 1 month showed the correct endograft position, descending thoracic aorta ulcer exclusion with no signs of endoleak. In selected cases, this method allows planning in advance safe stent graft positioning and deployment totally assisted by transesophageal echography, with no risk of periprocedural contrast-related renal failure and reduced radiation exposure for the patient and operators. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Remifentanil in critically ill cardiac patients

    Directory of Open Access Journals (Sweden)

    Ruggeri Laura

    2011-01-01

    Full Text Available Remifentanil has a unique pharmacokinetic profile, with a rapid onset and offset of action and a plasmatic metabolism. Its use can be recommended even in patients with renal impairment, hepatic dysfunction or poor cardiovascular function. A potential protective cardiac preconditioning effect has been suggested. Drug-related adverse effects seem to be comparable with other opioids. In cardiac surgery, many randomized controlled trials demonstrated that the potential benefits of the use of remifentanil not only include a profound protection against intraoperative stressful stimuli, but also rapid postoperative recovery, early weaning from mechanical ventilation, and extubation. Remifentanil shows ideal properties of sedative agents being often employed for minimally invasive cardiologic techniques, such as transcatheter aortic valve implantation and radio frequency treatment of atrial flutter, or diagnostic procedures such as transesophageal echocardiography. In intensive care units remifentanil is associated with a reduction in the time to tracheal extubation after cessation of the continuous infusion; other advantages could be more evident in patients with organ dysfunction. Effective and safe analgesia can be provided in case of short and painful procedures (i.e. chest drain removal. In conclusion, thanks to its peculiar properties, remifentanil will probably play a major role in critically ill cardiac patients.

  1. Incremental Value of Three-Dimensional Transesophageal Echocardiography over the Two-Dimensional Technique in the Assessment of a Thrombus in Transit through a Patent Foramen Ovale.

    Science.gov (United States)

    Thind, Munveer; Ahmed, Mustafa I; Gok, Gulay; Joson, Marisa; Elsayed, Mahmoud; Tuck, Benjamin C; Townsley, Matthew M; Klas, Berthold; McGiffin, David C; Nanda, Navin C

    2015-05-01

    We report a case of a right atrial thrombus traversing a patent foramen ovale into the left atrium, where three-dimensional transesophageal echocardiography provided considerable incremental value over two-dimensional transesophageal echocardiography in its assessment. As well as allowing us to better spatially characterize the thrombus, three-dimensional transesophageal echocardiography provided a more quantitative assessment through estimation of total thrombus burden. © 2015, Wiley Periodicals, Inc.

  2. Determination of the optimum number of cardiac cycles to differentiate intra-pulmonary shunt and patent foramen ovale by saline contrast two- and three-dimensional echocardiography.

    Science.gov (United States)

    Bhatia, Nirmanmoh; Abushora, Mohannad Y; Donneyong, Macarius M; Stoddard, Marcus F

    2014-03-01

    Patent foramen ovale (PFO) and intra-pulmonary shunt (IPS) are potential causes of stroke. The most optimum cardiac cycle cutoff for bubbles to appear in the left heart on saline contrast transthoracic echocardiography (TTE) as criteria to differentiate the 2 entities is unknown. Ninety-five adult patients had saline contrast transesophageal echocardiography (TEE), two-dimensional (2D) and 3DTTE. Sensitivity and specificity of each cardiac cycle as cutoff to differentiate a PFO and IPS were obtained. Transesophageal echocardiography showed IPS in 28 and PFO in 15 patients. If bubbles appeared in the left heart within the first 4 cardiac cycles (the 4th cardiac cycle rule) as compared to alternate cutoffs, a PFO was most accurately diagnosed by both 2D and 3DTTE. Bubbles appearing at or after the 5th cardiac cycle most accurately determined an IPS. 3D versus 2DTTE had a trend for a higher sensitivity (61% vs. 36%, P = 0.06), but similar specificity (94% vs. 91%) for IPS. Accuracy of 3DTTE was 84% and 2DTTE was 75% (P = 0.08) for IPS. For PFO, 2DTTE sensitivity (87%) and specificity (98%) did not differ (P = NS) from that of 3DTTE sensitivity (73%) and specificity (100%). This study demonstrates for the first time that the 4th cardiac cycle rule differentiates PFO and IPS most optimally by 2D and 3DTTE. 3DTTE appears to have higher sensitivity for diagnosing IPS. These data suggest that 3DTTE is preferable when IPS is to be diagnosed. Both methods are similar for diagnosing PFO. © 2013, Wiley Periodicals, Inc.

  3. Anatomical characteristics of pulmonary veins for the prediction of postoperative recurrence after radiofrequency catheter ablation of atrial fibrillation.

    Directory of Open Access Journals (Sweden)

    Wei Wei

    Full Text Available BACKGROUND: The relationship between focal pulmonary vein potential and atrial fibrillation (AF has been confirmed. Pulmonary vein (PV isolation and circumferential pulmonary vein ablation have been the most commonly used procedures of radiofrequency ablation. However, few studies have investigated the relationship between anatomical characteristics of PV and AF recurrences after radiofrequency ablation. METHODOLOGY: For 267 AF patients treated by radiofrequency catheter ablation, the anatomic structure characteristics of pulmonary veins were assessed by multi-slice spiral computed tomography while the values of left atrial diameter (LAD were measured with transesophageal ultrasonic cardiogram. After radiofrequency catheter ablation, postoperative recurrence was evaluated during a 10-month term follow-up. PRINCIPAL FINDINGS: During follow-up, postoperative recurrence occurred in 44 patients. The mean diameters of LAD, left superior PV, right superior PV, all left PV, and all superior PV were significantly larger in patients with postoperative recurrence (Recurrence vs. Non-recurrence group; 43.9 ± 6.4 mm vs. 40.7 ± 5.6 mm; 18.4 ± 2.1 mm vs. 17.1 ± 3.1 mm; 18.2 ± 2.8 mm vs. 17.2 mm ± 3.9 mm; 16.4 ± 1.5 mm vs. 15.6 ± 2.5 mm; 18.3 ± 2.1 mm vs. 17.1 ± 3.0 mm; respectively; all P < 0.05. Multivariable survival analysis showed that the type and the course of AF, LAD, and the diameters of all superior PV were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation. CONCLUSIONS: The enlargements of all superior PV and LAD, long course of diseases, and persistent AF were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.

  4. Preparation of liposomal amiodarone and investigation of its cardiomyocyte-targeting ability in cardiac radiofrequency ablation rat model

    Directory of Open Access Journals (Sweden)

    Zhuge Y

    2016-05-01

    Full Text Available Ying Zhuge,1,* Zhi-Feng Zheng,1,* Mu-Qing Xie,2 Lin Li,2 Fang Wang,1 Feng Gao2,3 1Department of Cardiology, Shanghai First People’s Hospital of Nanjing Medical University, 2Department of Pharmaceutics, School of Pharmacy, 3Shanghai Key Laboratory of Functional Materials Chemistry, East China University of Science and Technology, Shanghai, People’s Republic of China*These authors contributed equally to this workAbstract: The objective of this study was to develop an amiodarone hydrochloride (ADHC-loaded liposome (ADHC-L formulation and investigate its potential for cardiomyocyte targeting after cardiac radiofrequency ablation (CA in vivo. The ADHC-L was prepared by thin-film method combined with ultrasonication and extrusion. The preparation process was optimized by Box–Behnken design with encapsulation efficiency as the main evaluation index. The optimum formulation was quantitatively obtained with a diameter of 99.9±0.4 nm, a zeta potential of 35.1±10.9 mV, and an encapsulation efficiency of 99.5%±13.3%. Transmission electron microscopy showed that the liposomes were spherical particles with integrated bilayers and well dispersed with high colloidal stability. Pharmacokinetic studies were investigated in rats after intravenous administration, which revealed that compared with free ADHC treatment, ADHC-L treatment showed a 5.1-fold increase in the area under the plasma drug concentration–time curve over a period of 24 hours (AUC0–24 h and an 8.5-fold increase in mean residence time, suggesting that ADHC-L could facilitate drug release in a more stable and sustained manner while increasing the circulation time of ADHC, especially in the blood. Biodistribution studies of ADHC-L demonstrated that ADHC concentration in the heart was 4.1 times higher after ADHC-L treatment in CA rat model compared with ADHC-L sham-operated treatment at 20 minutes postinjection. Fluorescence imaging studies further proved that the heart

  5. Off-pump atrial septostomy with thoracoscopic scissors under transesophageal echocardiography guidance

    Directory of Open Access Journals (Sweden)

    Raj R Benedict

    2013-01-01

    Full Text Available Selected children with congenital heart defects undergoing palliative closed heart procedures require a cardiopulmonary bypass (CPB run only for the purpose of creating an inter-atrial communication. We report a simple technique of atrial septostomy using thoracoscopy scissors under transesophageal echocardiography guidance without the need for CPB.

  6. Measurement of thrombus flux using transesophageal Echocardiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tadashi; Hirai, Kazuki; Aoki, Masami; Miyagi, Jin; Suzuki, Masahiko; Moriya, Hideshige; Hachiya Hiroyuki

    2006-01-01

    Deep venous thrombosis (DVT) and pulmonary thromboembolism (PTE) are serious problem of total knee replacement (TKR). These diseases may be caused by a thrombus formed during the TKR operation. Therefore, understanding the flow volume of thrombus is important for curing and preventing PTE. In this paper, we tried to understanding the situation of the flow of thrombus by using transesophageal echocardiography movies. We applied the signal processing technique the fiber structure extraction technique (FSET) to extract the anomalous information from ultrasonic echo image. As a result of processing, the time change of the flow volume of thrombus was confirmed. (author)

  7. Right atrium positioning for exposure of right pulmonary veins during off-pump atrial fibrillation ablation.

    Science.gov (United States)

    Suwalski, Grzegorz; Emery, Robert; Mróz, Jakub; Kaczejko, Kamil; Gryszko, Leszek; Cwetsch, Andrzej; Skrobowski, Andrzej

    2017-06-01

    Concomitant surgical ablation of atrial fibrillation (AF) is recommended for patients undergoing off-pump coronary revascularization in the presence of this arrhythmia. Achievement of optimal visualization of pulmonary veins while maintaining stable haemodynamic conditions is crucial for proper completion of the ablation procedure. This study evaluates the safety and feasibility of right atrial positioning using a suction-based cardiac positioner as opposed to compressive manoeuvres for exposure during off-pump surgical ablation for AF. Thirty-four consecutive patients underwent pulmonary vein isolation, ganglionated plexi ablation and left atrial appendage occlusion during off-pump coronary artery bypass grafting. Right atrial suction positioning was used to visualize right pulmonary veins. Safety and feasibility end points were analysed intraoperatively and in the early postoperative course. In all patients, right atrial positioning created optimal conditions to complete transverse and oblique sinus blunt dissection, correct placement of a bipolar ablation probe, detection and ablation of ganglionated plexi and conduction block assessment. In all patients, this entire right-sided ablation procedure was completed with a single exposure manoeuvre. Feasibility end points were achieved in all study patients. This report documents the safety and feasibility of right atrial exposure using a suction-based cardiac positioner to complete ablation for AF concomitant with off-pump coronary revascularization. This technique may be widely adopted to create stable haemodynamic conditions and optimal visualization of the right pulmonary veins. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. A review of the safety aspects of radio frequency ablation

    Directory of Open Access Journals (Sweden)

    Abhishek Bhaskaran

    2015-09-01

    Full Text Available In light of recent reports showing high incidence of silent cerebral infarcts and organized atrial arrhythmias following radiofrequency (RF atrial fibrillation (AF ablation, a review of its safety aspects is timely. Serious complications do occur during supraventricular tachycardia (SVT ablations and knowledge of their incidence is important when deciding whether to proceed with ablation. Evidence is emerging for the probable role of prophylactic ischemic scar ablation to prevent VT. This might increase the number of procedures performed. Here we look at the various complications of RF ablation and also the methods to minimize them. Electronic database was searched for relevant articles from 1990 to 2015. With better awareness and technological advancements in RF ablation the incidence of complications has improved considerably. In AF ablation it has decreased from 6% to less than 4% comprising of vascular complications, cardiac tamponade, stroke, phrenic nerve injury, pulmonary vein stenosis, atrio-esophageal fistula (AEF and death. Safety of SVT ablation has also improved with less than 1% incidence of AV node injury in AVNRT ablation. In VT ablation the incidence of major complications was 5–11%, up to 3.4%, up to 1.8% and 4.1–8.8% in patients with structural heart disease, without structural heart disease, prophylactic ablations and epicardial ablations respectively. Vascular and pericardial complications dominated endocardial and epicardial VT ablations respectively. Up to 3% mortality and similar rates of tamponade were reported in endocardial VT ablation. Recent reports about the high incidence of asymptomatic cerebral embolism during AF ablation are concerning, warranting more research into its etiology and prevention.

  9. Collateral findings during computed tomography scan for atrial fibrillation ablation: Let's take a look around.

    Science.gov (United States)

    Perna, Francesco; Casella, Michela; Narducci, Maria Lucia; Dello Russo, Antonio; Bencardino, Gianluigi; Pontone, Gianluca; Pelargonio, Gemma; Andreini, Daniele; Vitulano, Nicola; Pizzamiglio, Francesca; Conte, Edoardo; Crea, Filippo; Tondo, Claudio

    2016-04-26

    The growing number of atrial fibrillation catheter ablation procedures warranted the development of advanced cardiac mapping techniques, such as image integration between electroanatomical map and cardiac computed tomography. While scanning the chest before catheter ablation, it is frequent to detect cardiac and extracardiac collateral findings. Most collateral findings are promptly recognized as benign and do not require further attention. However, sometimes clinically relevant collateral findings are detected, which often warrant extra diagnostic examinations or even invasive procedure, and sometimes need to be followed-up over time. Even though reporting and further investigating collateral findings has not shown a clear survival benefit, almost all the working groups providing data on collateral findings reported some collateral findings eventually coming out to be malignancies, sometimes at an early stage. Therefore, there is currently no clear agreement about the right strategy to be followed.

  10. Cardiac function in acute hypothyroidism

    International Nuclear Information System (INIS)

    Donaghue, K.; Hales, I.; Allwright, S.; Cooper, R.; Edwards, A.; Grant, S.; Morrow, A.; Wilmshurst, E.; Royal North Shore Hospital, Sydney

    1985-01-01

    It has been established that chronic hypothyroidism may affect cardiac function by several mechanisms. It is not known how long the patient has to be hypothyroid for cardiac involvement to develop. This study was undertaken to assess the effect of a short period of hypothyroidism (10 days) on cardiac function. Nine patients who had had total tyroidectomy, had received ablative radioiodine for thyroid cancer and were euthyroid on replacement therapy were studied while both euthyroid and hypothyroid. Cardiac assessment was performed by X-ray, ECG, echocardiography and gated blood-pool scans. After 10 days of hypothyroidisms, the left-ventricular ejection fraction failed to rise after exercise in 4 of the 9 patients studied, which was significant (P<0.002). No significant changes in cardiac size or function at rest were detected. This functional abnormality in the absence of any demonstrable change in cardiac size and the absence of pericardial effussion with normal basal function suggest that short periods of hypothyroidism may reduce cardiac reserve, mostly because of alterations in metabolic function. (orig.)

  11. Diagnosis and treatment of shock due to massive pulmonary embolism: approach with transesophageal echocardiography and intrapulmonary thrombolysis.

    Science.gov (United States)

    Krivec, B; Voga, G; Zuran, I; Skale, R; Pareznik, R; Podbregar, M; Noc, M

    1997-11-05

    To evaluate the diagnostic value of transesophageal echocardiography (TEE) as an initial diagnostic tool in shocked patients. The second objective was to study therapeutic impact of intrapulmonary thrombolysis in patients with diagnosed massive pulmonary embolism. Prospective observational study. Medical ICU in 800-bed general hospital. Twenty-four consecutive patients with unexplained shock and distended jugular veins. In 18 patients, right ventricular dilatation with global or segmental hypokinesis was documented. In addition, central pulmonary thromboemboli (12 patients), reduced contrast flow in right pulmonary artery (one patient), and right ventricular free wall akinesis (one patient) were found. No additional echocardiographic findings were apparent in four patients. According to pulmonary scintigraphy or autopsy, sensitivity of TEE for diagnosis of massive pulmonary embolism (MPE) in patients with right ventricular dilatation was 92% and specificity was 100%. In patients without right ventricular dilatation, left ventricular dysfunction (four patients) or cardiac tamponade (two patients) was confirmed. Intrapulmonary thrombolysis was evaluated in 11 of 13 patients with MPE. Two patients died prior to attempted thrombolysis. Three patients received streptokinase and eight received urokinase. Twenty-four hours after beginning of treatment, total pulmonary resistance index significantly decreased for 59% and mean pulmonary artery pressure for 31%. Cardiac index increased for 74%. Nine of 11 patients receiving thrombolysis survived to hospital discharge. Bedside TEE is a valuable tool for diagnosis of MPE. It enables immediate intrapulmonary thrombolysis, which seems to be an effective therapeutic alternative in our group of patients with obstructive shock.

  12. Three-dimensional transesophageal echocardiography in the evaluation of aortic valve destruction by endocarditis

    NARCIS (Netherlands)

    Nemes, Attila; Lagrand, Wim K.; McGhie, Jackie S.; ten Cate, Folkert J.

    2006-01-01

    Infective endocarditis remains a serious and complex disease with significant morbidity and mortality. The aim of this study was to demonstrate the clinical usefulness of 3-dimensional transesophageal echocardiography for the spatial assessment of aortic valve endocarditis. This case showed severe

  13. Mechanisms for enlarging lesion size during irrigated tip radiofrequency ablation

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Roman-Gonzalez, Javier; Johnson, Susan B

    2004-01-01

    INTRODUCTION: Irrigated tip radiofrequency ablation of cardiac arrhythmias was developed to increase the size of the radiofrequency-induced lesion, since cooling of the electrode tip allows use of higher power settings. The purpose of this study was to determine if the increased lesion size during...

  14. Successful Ablation for Atrial Tachycardia Originated from Sinus Venosa with Tachycardia-Induced Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Sou Takenaka

    2016-01-01

    Full Text Available A 74-year-old male suffering from congestive heart failure with atrial tachycardia (AT with 2 : 1 atrioventricular conduction was admitted to our hospital. After the therapy with diuretics and β-blocker, his rapid AT was still sustained. He took the catheter ablation for his AT. Postpacing interval mapping from entrainment and noncontact mapping system revealed the mechanism of his AT, originated from sinus venosa. His AT was successfully terminated and eliminated by radiofrequency catheter ablation. After the successful ablation, he has been free from any AT, and his cardiac function was also improved.

  15. Cardiac expression of microsomal triglyceride transfer protein is increased in obesity and serves to attenuate cardiac triglyceride accumulation

    DEFF Research Database (Denmark)

    Bartels, Emil D; Nielsen, Jan M; Hellgren, Lars I

    2009-01-01

    Obesity causes lipid accumulation in the heart and may lead to lipotoxic heart disease. Traditionally, the size of the cardiac triglyceride pool is thought to reflect the balance between uptake and beta-oxidation of fatty acids. However, triglycerides can also be exported from cardiomyocytes via...... secretion of apolipoproteinB-containing (apoB) lipoproteins. Lipoprotein formation depends on expression of microsomal triglyceride transfer protein (MTP); the mouse expresses two isoforms of MTP, A and B. Since many aspects of the link between obesity-induced cardiac disease and cardiac lipid metabolism...... remain unknown, we investigated how cardiac lipoprotein synthesis affects cardiac expression of triglyceride metabolism-controlling genes, insulin sensitivity, and function in obese mice. Heart-specific ablation of MTP-A in mice using Cre-loxP technology impaired upregulation of MTP expression...

  16. Echocardiography in patients with complications related to pacemakers and cardiac defibrillators.

    Science.gov (United States)

    Almomani, Ahmed; Siddiqui, Khadija; Ahmad, Masood

    2014-03-01

    The evolving indications and uses for implantable cardiac devices have led to a significant increase in the number of implanted devices each year. Implantation of endocardial leads for permanent pacemakers and cardiac defibrillators can cause many delayed complications. Complications may be mechanical and related to the interaction of the device leads with the valves and endomyocardium, e.g., perforation, infection, and thrombosis, or due to the electrical pacing of the myocardium and conduction abnormalities, e.g., left ventricular dyssynchrony. Tricuspid regurgitation, another delayed complication in these patients, may be secondary to both mechanical and pacing effects of the device leads. Echocardiography plays an important role in the diagnosis of these device-related complications. Both two-dimensional transthoracic echocardiography and transesophageal echocardiography provide useful diagnostic information. Real time three-dimensional echocardiography is a novel technique that can further enhance the detection of lead-related complications. © 2013, Wiley Periodicals, Inc.

  17. Diagnostic accuracy of transesophageal echocardiogram for the detection of patent foramen ovale: a meta-analysis.

    Science.gov (United States)

    Mojadidi, Mohammad Khalid; Bogush, Nikolay; Caceres, Jose Diego; Msaouel, Pavlos; Tobis, Jonathan M

    2014-07-01

    Patent foramen ovale (PFO) is a remnant of the fetal circulation present in 20% of the population. Right-to-left shunting (RLS) through a PFO has been linked to the pathophysiology of stroke, migraine with aura, and hypoxemia. While different imaging modalities including transcranial Doppler, intra-cardiac echo, and transthoracic echo (TTE) have often been used to detect RLS, transesophageal echo (TEE) bubble study remains the gold standard for diagnosing PFO. The aim of this study was to determine the relative accuracy of TEE in the detection of PFO. A systematic review of Medline, using a standard approach for meta-analysis, was performed for all prospective studies assessing accuracy of TEE in the detection of PFO using confirmation by autopsy, cardiac surgery, and/or catheterization as the reference. Search results revealed 3105 studies; 4 met inclusion criteria. A total of 164 patients were included. TEE had a weighted sensitivity of 89.2% (95% CI: 81.1-94.7%) and specificity of 91.4% (95% CI: 82.3-96.8%) to detect PFO. The overall positive likelihood ratio (LR+) was 5.93 (95% CI: 1.30-27.09) and the overall negative likelihood ratio (LR-) was 0.22 (95% CI: 0.08-0.56). While TEE bubble study is considered to be the gold standard modality for diagnosing PFO, some PFOs may still be missed or misdiagnosed. It is important to understand the limitations of TEE and perhaps use other highly sensitive screening tests, such as transcranial doppler (TCD), in conjunction with TEE before scheduling a patient for transcatheter PFO closure. © 2013, Wiley Periodicals, Inc.

  18. Guidelines for the Use of Echocardiography in the Evaluation of a Cardiac Source of Embolism.

    Science.gov (United States)

    Saric, Muhamed; Armour, Alicia C; Arnaout, M Samir; Chaudhry, Farooq A; Grimm, Richard A; Kronzon, Itzhak; Landeck, Bruce F; Maganti, Kameswari; Michelena, Hector I; Tolstrup, Kirsten

    2016-01-01

    Embolism from the heart or the thoracic aorta often leads to clinically significant morbidity and mortality due to transient ischemic attack, stroke or occlusion of peripheral arteries. Transthoracic and transesophageal echocardiography are the key diagnostic modalities for evaluation, diagnosis, and management of stroke, systemic and pulmonary embolism. This document provides comprehensive American Society of Echocardiography guidelines on the use of echocardiography for evaluation of cardiac sources of embolism. It describes general mechanisms of stroke and systemic embolism; the specific role of cardiac and aortic sources in stroke, and systemic and pulmonary embolism; the role of echocardiography in evaluation, diagnosis, and management of cardiac and aortic sources of emboli including the incremental value of contrast and 3D echocardiography; and a brief description of alternative imaging techniques and their role in the evaluation of cardiac sources of emboli. Specific guidelines are provided for each category of embolic sources including the left atrium and left atrial appendage, left ventricle, heart valves, cardiac tumors, and thoracic aorta. In addition, there are recommendation regarding pulmonary embolism, and embolism related to cardiovascular surgery and percutaneous procedures. The guidelines also include a dedicated section on cardiac sources of embolism in pediatric populations. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  19. Antenatal management of recurrent fetal goitrous hyperthyroidism associated with fetal cardiac failure in a pregnant woman with persistent high levels of thyroid-stimulating hormone receptor antibody after ablative therapy.

    Science.gov (United States)

    Matsumoto, Tadashi; Miyakoshi, Kei; Saisho, Yoshifumi; Ishii, Tomohiro; Ikenoue, Satoru; Kasuga, Yoshifumi; Kadohira, Ikuko; Sato, Seiji; Momotani, Naoko; Minegishi, Kazuhiro; Yoshimura, Yasunori

    2013-01-01

    High titer of maternal thyroid-stimulating hormone receptor antibody (TRAb) in patients with Graves' disease could cause fetal hyperthyroidism during pregnancy. Clinical features of fetal hyperthyroidism include tachycardia, goiter, growth restriction, advanced bone maturation, cardiomegaly, and fetal death. The recognition and treatment of fetal hyperthyroidism are believed to be important to optimize growth and intellectual development in affected fetuses. We herein report a case of fetal treatment in two successive siblings showing in utero hyperthyroid status in a woman with a history of ablative treatment for Graves' disease. The fetuses were considered in hyperthyroid status based on high levels of maternal TRAb, a goiter, and persistent tachycardia. In particular, cardiac failure was observed in the second fetus. With intrauterine treatment using potassium iodine and propylthiouracil, fetal cardiac function improved. A high level of TRAb was detected in the both neonates. To the best of our knowledge, this is the first report on the changes of fetal cardiac function in response to fetal treatment in two siblings showing in utero hyperthyroid status. This case report illustrates the impact of prenatal medication via the maternal circulation for fetal hyperthyroidism and cardiac failure.

  20. Bilateral occipital lobe infarction with altitudinal field loss following radiofrequency cardiac catheter ablation

    Directory of Open Access Journals (Sweden)

    Chen Celia S

    2010-03-01

    Full Text Available Abstract Background Bilateral stroke following radiofrequency catheter ablation is an unusual complication and may result in bilateral altitudinal visual field defects. Bilateral altitudinal visual field defects usually result from prechiasmal pathology causing damage to both retinas or optic nerves and rarely from bilateral symmetric damage to the post chiasmal visual pathways. Case presentation A 48-year-old man complained of visual disturbance on wakening following radiofrequency catheter ablation. The patient had a CHADS score of 1 pre-operatively and no complications were noted intra-operatively. Examination revealed a bilateral superior altitudinal defect and MRI of the brain showed multifocal areas of infarction predominantly involving the occipital lobes which correlated to with the visual deficits. Conclusion While the risk of thromboembolism and perioperative stroke during radiofrequency catheter ablation is small, it is not insignificant.

  1. Evaluation of prosthetic heart valves by transesophageal echocardiography: problems, pitfalls, and timing of echocardiography

    NARCIS (Netherlands)

    van den Brink, Renee B. A.

    2006-01-01

    Transesophageal echocardiography (TEE) is especially suitable for examination of prosthetic valves because of the proximity of the esophagus to the heart and absence of interference with lungs and ribs. This article reviews normal and abnormal morphologic characteristics of prosthetic valves such as

  2. Catheter Ablation versus Thoracoscopic Surgical Ablation in Long Standing Persistent Atrial Fibrillation (CASA-AF): study protocol for a randomised controlled trial.

    Science.gov (United States)

    Khan, Habib Rehman; Kralj-Hans, Ines; Haldar, Shouvik; Bahrami, Toufan; Clague, Jonathan; De Souza, Anthony; Francis, Darrel; Hussain, Wajid; Jarman, Julian; Jones, David Gareth; Mediratta, Neeraj; Mohiaddin, Raad; Salukhe, Tushar; Jones, Simon; Lord, Joanne; Murphy, Caroline; Kelly, Joanna; Markides, Vias; Gupta, Dhiraj; Wong, Tom

    2018-02-20

    Atrial fibrillation is the commonest arrhythmia which raises the risk of heart failure, thromboembolic stroke, morbidity and death. Pharmacological treatments of this condition are focused on heart rate control, rhythm control and reduction in risk of stroke. Selective ablation of cardiac tissues resulting in isolation of areas causing atrial fibrillation is another treatment strategy which can be delivered by two minimally invasive interventions: percutaneous catheter ablation and thoracoscopic surgical ablation. The main purpose of this trial is to compare the effectiveness and safety of these two interventions. Catheter Ablation versus Thoracoscopic Surgical Ablation in Long Standing Persistent Atrial Fibrillation (CASA-AF) is a prospective, multi-centre, randomised controlled trial within three NHS tertiary cardiovascular centres specialising in treatment of atrial fibrillation. Eligible adults (n = 120) with symptomatic, long-standing, persistent atrial fibrillation will be randomly allocated to either catheter ablation or thoracoscopic ablation in a 1:1 ratio. Pre-determined lesion sets will be delivered in each treatment arm with confirmation of appropriate conduction block. All patients will have an implantable loop recorder (ILR) inserted subcutaneously immediately following ablation to enable continuous heart rhythm monitoring for at least 12 months. The devices will be programmed to detect episodes of atrial fibrillation and atrial tachycardia ≥ 30 s in duration. The patients will be followed for 12 months, completing appropriate clinical assessments and questionnaires every 3 months. The ILR data will be wirelessly transmitted daily and evaluated every month for the duration of the follow-up. The primary endpoint in the study is freedom from atrial fibrillation and atrial tachycardia at the end of the follow-up period. The CASA-AF Trial is a National Institute for Health Research-funded study that will provide first-class evidence on the

  3. Different Modes of Monitoring and Correction of Cardiac Function During Operations Under Extracorporeal Circulation

    Directory of Open Access Journals (Sweden)

    L. A. Krichevsky

    2007-01-01

    Full Text Available Objective: to comparatively evaluate the efficiency of intensive care measures chosen on the basis of traditional monitoring of central hemodynamics (CH or on that of the data of transesophageal echocardiography (TE echoCG.Materials and methods: 50 patients were examined at coronary bypass surgery under extracorporeal circulation. Under a prospective comparative analysis were two algorithms of treatment policy: maintenance of cardiac index, by using the maximum volemic load, or that of left ventricular systolic function under guidance of transesophageal echocardiography.Results: Significantly (p<0.05 larger doses of dopamine and/or dobutamine were required to maintain adequate left ventricular systolic function. However, this treatment policy showed much better (p<0.05 circulatory parameters in the postperfusion period. At the same time the duration of postoperative inotropic therapy in these patients proved to be significantly (p<0.05 less.Conclusion. The treatment policy based on the maintenance of left ventricular systolic function under guidance of TE echoCG leads to the shortest circulatory stabilization during myocardial revascularization. The application of a volemic load and the expectant use of inotropic drugs result in a longer restoration of operated heart function. 

  4. Critical phase transitions during ablation of atrial fibrillation

    Science.gov (United States)

    Iravanian, Shahriar; Langberg, Jonathan J.

    2017-09-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia with significant morbidity and mortality. Pharmacological agents are not very effective in the management of AF. Therefore, ablation procedures have become the mainstay of AF management. The irregular and seemingly chaotic atrial activity in AF is caused by one or more meandering spiral waves. Previously, we have shown the presence of sudden rhythm organization during ablation of persistent AF. We hypothesize that the observed transitions from a disorganized to an organized rhythm is a critical phase transition. Here, we explore this hypothesis by simulating ablation in an anatomically-correct 3D AF model. In 722 out of 2160 simulated ablation, at least one sudden transition from AF to an organized rhythm (flutter) was noted (33%). They were marked by a sudden decrease in the cycle length entropy and increase in the mean cycle length. At the same time, the number of reentrant wavelets decreased from 2.99 ± 0.06 in AF to 1.76 ± 0.05 during flutter, and the correlation length scale increased from 13.3 ± 1.0 mm to 196.5 ± 86.6 mm (both P < 0.0001). These findings are consistent with the hypothesis that transitions from AF to an anatomical flutter behave as phase transitions in complex non-equilibrium dynamical systems with flutter acting as an absorbing state. Clinically, the facilitation of phase transition should be considered a novel mechanism of ablation and may help to design effective ablation strategies.

  5. Bundle branch block after ablation for Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Fuenmayor A, Abdel J; Rodríguez S, Yenny A

    2013-09-20

    Bundle branch block (BBB) is a difficult diagnosis in the Wolff-Parkinson-White syndrome (WPW). We investigated the clinical implications of BBB that appears after performing an accessory pathway (AP) ablation. We studied 199 patients with WPW who were submitted to AP ablation. Thirty (15%) exhibited BBB after the ablation. Twenty-two patients had right BBB and 8 had left BBB. Thirteen patients had right-sided AP and 17 had left-sided AP. They were compared with 82 similar patients without BBB after the AP ablation. Among the patients with BBB, 86.66% showed delays in the middle part of the QRS in the ECG recorded before ablation vs. 18.29% of the patients without BBB (p<0.05) (sensitivity 86%, specificity 81%, positive predictive value 67% and negative predictive value 93%). Forty-four percent of the patients with BBB had BBB morphology during orthodromic tachycardia vs. 10% of the patients without BBB (p<0.05) (sensitivity 44%, specificity 89%, positive predictive value 57% and negative predictive value 82%). No relationship was found between AP location and the site of the BBB. Ejection fraction was normal before (0.61 ± 0.03) and upon completion of follow-up (0.61 ± 0.07). BBB disappeared in 95.3% of the patients. Delays in the middle portion of the QRS may predict BBB after AP ablation. BBB after performing AP ablation is frequent, transient, benign, and not related to either the ablation lesion location or progression to structural heart disease. BBB after AP ablation may be related to cardiac memory. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Interatrial septum thickness and difficulty with transseptal puncture during redo catheter ablation of atrial fibrillation.

    Science.gov (United States)

    Tomlinson, David R; Sabharwal, Nikant; Bashir, Yaver; Betts, Timothy R

    2008-12-01

    Patients undergoing catheter ablation for atrial fibrillation (AF) frequently require redo procedures, but there are no data reporting interatrial septum thickness (IAS) and difficulty during repeat transseptal puncture (TSP). Patients undergoing two separate AF ablation procedures had preprocedural fossa ovalis (FO) thickness measured using transesophageal echocardiography (TEE). "Difficult" TSP was defined by two observers as requiring excessive force, or conversion to TEE guidance. The study comprised 42 patients (37 male) with mean+/-SD age 55+/-9 years. Mean FO thickness was significantly greater at the time of redo TSP (2.2+/-1.6 mm vs 2.6+/-1.5 mm at redo, P=0.03); however, this finding was limited to those who underwent initial dual transseptal sheath procedures, FO thickness 2.0+/-1.5 mm and 2.5+/-1.4 mm for TEE 1 and 2, respectively (P=0.048). There was a trend for more frequent difficult redo TSP procedures, 7/42 (17%; 95% confidence interval [CI] 8-31) redo, versus 4/42 (10%; 95% CI 3-23) first TSP. On univariate analysis, FO thickness was not predictive of TSP difficulty; the only predictor of difficult redo TSP was diabetes. IAS thickness at the FO increased following catheter ablation of AF, yet on subgroup analysis this was limited to initial procedures utilizing dual transseptal sheaths. There was a trend toward more frequent difficulty during redo TSP, yet this was not associated with FO thickening. Diabetes may predispose to difficulty during redo TSP; this finding requires confirmation in a larger study population.

  7. Cardiac imaging : X-ray, magnetic resonance and ultrasound in congenital heart diseases

    International Nuclear Information System (INIS)

    Rigby, M.L.

    1991-01-01

    In many instances, the management of simple or common congenital cardiac anomalies, such as patient arterial duct, atrial septal defect or ventricular septal defect, can be based upon clinical evaluation, the chest radiograph and conventional transthoracic echocardiography and Doppler investigation. Angiography is usually required for those conditions, such as the tetralogy of Fallot, in which the size and anatomy of the pulmonary arteries influence the timing or the type of surgical intervention. Interventional cardiac catheterization, however, requires high quality X-ray screening and, frequently, transesophageal echocardiography. The investigation of more complex anomalies, such as those in hearts with a univentricular atrioventricular connection, often involves several methods of investigation. These complex anomalies require complete morphological and physiological assessment in order to provide optimum medical and surgical management. Increasingly, the diagnosis is established in utero. Should termination of pregnancy then be encouraged? Or, should all patients be subjected to an aggressive medical and surgical treatment regimen to optimize the chances of a later successful Fontan operation? Finally, what is the role of cardiac transplantation or the Norwood operation in those infants in whom the long term prognosis of conventional treatment is considered to be poor? (author). 20 refs.; 6 figs

  8. Phrenic Nerve Injury After Catheter Ablation of Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Jacques Clementy

    2007-01-01

    Full Text Available Phrenic Nerve Injury (PNI has been well studied by cardiac surgeons. More recently it has been recognized as a potential complication of catheter ablation with a prevalence of 0.11 to 0.48 % after atrial fibrillation (AF ablation. This review will focus on PNI after AF ablation. Anatomical studies have shown a close relationship between the right phrenic nerve and it's proximity to the superior vena cava (SVC, and the antero-inferior part of the right superior pulmonary vein (RSPV. In addition, the proximity of the left phrenic nerve to the left atrial appendage has been well established. Independent of the type of ablation catheter (4mm, 8 mm, irrigated tip, balloon or energy source used (radiofrequency (RF, ultrasound, cryothermia, and laser; the risk of PNI exists during ablation at the critical areas listed above. Although up to thirty-one percent of patients with PNI after AF ablation remain asymptomatic, dyspnea remain the cardinal symptom and is present in all symptomatic patients. Despite the theoretical risk for significant adverse effect on functional status and quality of life, short-term outcomes from published studies appear favorable with 81% of patients with PNI having a complete recovery after 7 ± 7 months.Conclusion: Existing studies have described PNI as an uncommon but avoidable complication in patients undergoing pulmonary vein isolation for AF. Prior to ablation at the SVC, antero-inferior RSPV ostium or the left atrial appendage, pacing should be performed before energy delivery. If phrenic nerve capture is documented, energy delivery should be avoided at this site. Electrophysiologist's vigilance as well as pacing prior to ablation at high risk sites in close proximity to the phrenic nerve are the currently available tools to avoid the complication of PNI.

  9. Three-dimensional echocardiography of normal and pathologic mitral valve: a comparison with two-dimensional transesophageal echocardiography

    NARCIS (Netherlands)

    Salustri, A.; Becker, A. E.; van Herwerden, L.; Vletter, W. B.; ten Cate, F. J.; Roelandt, J. R.

    1996-01-01

    This study was done to ascertain whether three-dimensional echocardiography can facilitate the diagnosis of mitral valve abnormalities. The value of the additional information provided by three-dimensional echocardiography compared with two-dimensional multiplane transesophageal echocardiography for

  10. The additional value of three-dimensional transesophageal echocardiography in complex aortic prosthetic heart valve endocarditis

    NARCIS (Netherlands)

    Tanis, Wilco; Teske, Arco J.; Van Herwerden, Lex A.; Chamuleau, Steven; Meijboom, Folkert; Budde, Ricardo P J; Cramer, MJ

    2015-01-01

    Background Two-dimensional transthoracic and transesophageal echocardiography (2DTTE and 2DTEE) may fail to detect signs of prosthetic heart valve (PHV) endocarditis due to acoustic shadowing. Three-dimensional (3D) TEE may have additional value; however, data are scarce. This study was performed to

  11. High incidence of echocardiographic abnormalities of the interatrial septum in patients undergoing ablation for atrial fibrillation.

    Science.gov (United States)

    Schernthaner, Christiana; Danmayr, Franz; Daburger, Apollonia; Eichinger, Jörg; Hammerer, Matthias; Strohmer, Bernhard

    2013-04-01

    Atrial fibrosis or fatty deposition is known to increase the propensity for the development of atrial fibrillation (AF). Apart from the pulmonic veins, the interatrial septum (IAS) might play a role in the maintenance of AF. In contrast to left atrial anatomy and adjacent veins, the IAS cannot be visualized in detail with computed tomography. Thus, preprocedural transesophageal echocardiography (TEE) may provide important morphologic information beyond exclusion from atrial thrombi. The study comprised 108 consecutive patients (mean age 60 ± 11 years; 98 men). AF was paroxysmal in 91 (84%) and persistent in 17 (16%) patients. We investigated the morphological characteristics of the IAS by TEE in patients who underwent radiofrequency ablation of AF. The IAS was structurally abnormal in 46 (43%) patients, showing the following echocardiograhic findings: atrial septal hypermobility or aneurysm (n = 27) associated with a patent foramen ovale (PFO) (n = 11) or with a small atrial septal defect (ASD) (n = 2), a septal flap associated with a PFO or an ASD (n = 8), and an abnormally thickened IAS (n = 12). A thrombus in the left atrial appendage was discovered in only 2 (2%) patients. A structurally abnormal IAS was diagnosed in nearly half of the patients undergoing ablation therapy for AF. The information obtained by TEE is mandatory to exclude left atrial thrombi prior the ablation procedure. Moreover, detailed knowledge of morphologic characteristics of the IAS facilitates an optimized and safe performance of the transseptal puncture using long sheaths with large diameters. © 2012, Wiley Periodicals, Inc.

  12. [Usefullness of transesophageal echocardiography in early detection of coronary spasm].

    Science.gov (United States)

    Sagara, M; Haraguchi, M; Hamu, Y; Isowaki, S; Yoshimura, N

    1996-04-01

    Intraoperative transesophageal echocardiography (TEE) was performed on a 62-year-old man who underwent abdominal aortic replacement for abdominal aortic aneurysm under general anesthesia combined with epidural anesthesia. Coronary artery spasm occurred after unexpected massive hemorrhage, and TEE showed hypokinesis in the posterior-inferior left ventricular wall. The changes in TEE preceded the ST elevation in the ECG. Bolus infusion of isosorbide dinitrate and continuous infusion of nitroglycerin alleviated these changes. TEE enabled us to detect and evaluate coronary spasm before the appearance of ST changes in ECG.

  13. The Role of Transesophageal Echocardiography in Endovascular Repair of Traumatic Aortic Transection

    Directory of Open Access Journals (Sweden)

    Swathy B

    2014-09-01

    Full Text Available Traumatic rupture of the thoracic aorta is a leading cause of death, following major blunt trauma, and endovascular repair has evolved as a viable alternative to open repair. This report highlights the role of transesophageal echocardiography as a valuable imaging tool for locating the exact position of the lesion, guiding placement of the endograft, detecting leaks around it and supplementing information derived from angiography during endograft deployment.

  14. Prediction of thrombus-related mechanical prosthetic valve dysfunction using transesophageal echocardiography

    Science.gov (United States)

    Lin, S. S.; Tiong, I. Y.; Asher, C. R.; Murphy, M. T.; Thomas, J. D.; Griffin, B. P.

    2000-01-01

    Identification of thrombus-related mechanical prosthetic valve dysfunction (MPVD) has important therapeutic implications. We sought to develop an algorithm, combining clinical and echocardiographic parameters, for prediction of thrombus-related MPVD in a series of 53 patients (24 men, age 52 +/- 16 years) who had intraoperative diagnosis of thrombus or pannus from 1992 to 1997. Clinical and echocardiographic parameters were analyzed to identify predictors of thrombus and pannus. Prevalence of thrombus and diagnostic yields relative to the number of predictors were determined. There were 22 patients with thrombus, 19 patients with pannus, and 12 patients with both. Forty-two of 53 masses were visualized using transesophageal echocardiography (TEE), including 29 of 34 thrombi or both thrombi and panni and 13 of 19 isolated panni. Predictors of thrombus or mixed presentation include mobile mass (p = 0.009), attachment to occluder (p = 0.02), elevated gradients (p = 0.04), and an international normalized ratio of or = 1 predictor. The prevalence of thrombus in the presence of or = 3 predictors is 14%, 69%, and 91%, respectively. Thus, TEE is sensitive in the identification of abnormal mass in the setting of MPVD. An algorithm based on clinical and transesophageal echocardiographic predictors may be useful to estimate the likelihood of thrombus in the setting of MPVD. In the presence of > or = 3 predictors, the probability of thrombus is high.

  15. Split-bolus single-phase cardiac multidetector computed tomography for reliable detection of left atrial thrombus. Comparison to transesophageal echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Staab, W.; Zwaka, P.A.; Sohns, J.M.; Schwarz, A.; Lotz, J. [University Medical Center Goettingen Univ. (Germany). Inst. for Diagnostic and Interventional Radiology; Sohns, C.; Vollmann, D.; Zabel, M.; Hasenfuss, G. [Goettingen Univ. (Germany). Dept. of Cardiology and Pneumology; Schneider, S. [Goettingen Univ. (Germany). Dept. of Medical Statistics

    2014-11-15

    Evaluation of a new cardiac MDCT protocol using a split-bolus contrast injection protocol and single MDCT scan for reliable diagnosis of LA/LAA thrombi in comparison to TEE, optimizing radiation exposure and use of contrast agent. A total of 182 consecutive patients with drug refractory AF scheduled for PVI (62.6% male, mean age: 64.1 ± 10.2 years) underwent routine diagnostic work including TEE and cardiac MDCT for the evaluation of LA/LAA anatomy and thrombus formation between November 2010 and March 2012. Contrast media injection was split into a pre-bolus of 30 ml and main bolus of 70 ml iodinated contrast agent separated by a short time delay. In this study, split-bolus cardiac MDCT identified 14 of 182 patients with filling defects of the LA/LAA. In all of these 14 patients, abnormalities were found in TEE. All 5 of the 14 patients with thrombus formation in cardiac MDCT were confirmed by TEE. MDCT was 100% accurate for thrombus, with strong but not perfect overall results for SEC equivalent on MDCT.

  16. Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Rettmann, Maryam E., E-mail: rettmann.maryam@mayo.edu; Holmes, David R.; Camp, Jon J.; Cameron, Bruce M.; Robb, Richard A. [Biomedical Imaging Resource, Mayo Clinic College of Medicine, Rochester, Minnesota 55905 (United States); Kwartowitz, David M. [Department of Bioengineering, Clemson University, Clemson, South Carolina 29634 (United States); Gunawan, Mia [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington D.C. 20057 (United States); Johnson, Susan B.; Packer, Douglas L. [Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota 55905 (United States); Dalegrave, Charles [Clinical Cardiac Electrophysiology, Cardiology Division Hospital Sao Paulo, Federal University of Sao Paulo, 04024-002 Brazil (Brazil); Kolasa, Mark W. [David Grant Medical Center, Fairfield, California 94535 (United States)

    2014-02-15

    Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved

  17. [Tapia's syndrome following transesophageal echocardiography during an open-heart operation: a case report].

    Science.gov (United States)

    Fujiwara, Satoru; Yoshimura, Hajime; Nishiya, Kenta; Oshima, Keiichi; Kawamoto, Michi; Kohara, Nobuo

    2017-12-27

    A 67-year-old man presented with hoarseness, dysarthria and deviation of the tongue to the left side the day after the open-heart operation under general anesthesia. Brain MRI demonstrated no causal lesion, and laryngoscope showed left vocal cord abductor palsy, so we diagnosed him with Tapia's syndrome (i.e., concomitant paralysis of the left recurrent and hypoglossal nerve). His neurological symptoms recovered gradually and improved completely four months after the onset. Tapia's syndrome is a rare condition caused by the extra cranial lesion of the recurrent laryngeal branch of the vagus nerve and the hypoglossal nerve, and mostly described as a complication of tracheal intubation. In this case, transesophageal echo probe has been held in the left side of the pharynx, so compression to the posterior wall of pharynx by the probe resulted in this condition, and to the best of our knowledge, this is the first report of Tapia's syndrome due to transesophageal echocardiography during an open-heart operation. This rare syndrome should be considered as a differential diagnosis of dysarthria and tongue deviation after a procedure associated with compression to the pharynx.

  18. Pellet ablation and ablation model development

    International Nuclear Information System (INIS)

    Houlberg, W.A.

    1989-01-01

    A broad survey of pellet ablation is given, based primarily on information presented at this meeting. The implications of various experimental observations for ablation theory are derived from qualitative arguments of the physics involved. The major elements of a more complete ablation theory are then outlined in terms of these observations. This is followed by a few suggestions on improving the connections between theory and experimental results through examination of ablation data. Although this is a rather aggressive undertaking for such a brief (and undoubtedly incomplete) assessment, some of the discussion may help us advance the understanding of pellet ablation. 17 refs

  19. Dynamics of tissue shrinkage during ablative temperature exposures

    International Nuclear Information System (INIS)

    Rossmann, Christian; Haemmerich, Dieter; Garrett-Mayer, Elizabeth; Rattay, Frank

    2014-01-01

    There is a lack of studies that examine the dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occurs due to protein denaturation, dehydration and contraction of collagen at temperatures greater 50 °C. This is particularly relevant for image-guided procedures such as tumor ablation, where pre- and post-treatment images are compared and any changes in dimensions must be considered to avoid misinterpretations of the treatment outcome. We present data from ex vivo, isothermal shrinkage tests in porcine liver tissue, where axial changes in tissue length were recorded during 15 min of heating to temperatures between 60 and 95 °C. A mathematical model was developed to accurately describe the time and temperature-dependent shrinkage behavior. The shrinkage dynamics had the same characteristics independent of temperature; the estimated relative shrinkage, adjusted for time since death, after 15 min heating to temperatures of 60, 65, 75, 85 and 95 °C, was 12.3, 13.8, 16.6, 19.2 and 21.7%, respectively. Our results demonstrate the shrinkage dynamics of organ tissues, and suggest the importance of considering tissue shrinkage for thermal ablative treatments. (paper)

  20. Successful radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia in a patient with dextrocardia due to unilateral pulmonary agenesis: a case report

    Directory of Open Access Journals (Sweden)

    Aksu T

    2015-02-01

    Full Text Available Tolga Aksu, Tumer Erdem Guler, Ebru Golcuk, Ismail Erden, Kazim Serhan Ozcan Department of Cardiology, Kocaeli Derince Education and Research Hospital, Derince, Kocaeli, Turkey Abstract: Radiofrequency catheter ablation of the slow pathway is considered to be the treatment of choice for patients with atrioventricular nodal reentrant tachycardia. We report a 34-year-old female with mirror image dextrocardia due to unilateral pulmonary agenesis who underwent successful slow pathway ablation for typical atrioventricular nodal reentrant tachycardia. Using contrast injection, cardiac anatomy was identified in a short time and successfully ablated. Keywords: dextrocardia, AVNRT, ablation, pulmonary agenesis

  1. Development of a Novel Shock Wave Catheter Ablation System

    Science.gov (United States)

    Yamamoto, H.; Hasebe, Yuhi; Kondo, Masateru; Fukuda, Koji; Takayama, Kazuyoshi; Shimokawa, Hiroaki

    Although radio-frequency catheter ablation (RFCA) is quite effective for the treatment tachyarrhythmias, it possesses two fundamental limitations, including limited efficacy for the treatment of ventricular tachyarrhythmias of epicardial origin and the risk of thromboembolism. Consequently, new method is required, which can eradicate arrhythmia source in deep part of cardiac muscle without heating. On the other hand, for a medical application of shock waves, extracorporeal shock wave lithotripter (ESWL) has been established [1]. It was demonstrated that the underwater shock focusing is one of most efficient method to generate a controlled high pressure in a small region [2]. In order to overcome limitations of existing methods, we aimed to develop a new catheter ablation system with underwater shock waves that can treat myocardium at arbitrary depth without causing heat.

  2. Cardiac expression of microsomal triglyceride transfer protein is increased in obesity and serves to attenuate cardiac triglyceride accumulation.

    Directory of Open Access Journals (Sweden)

    Emil D Bartels

    Full Text Available Obesity causes lipid accumulation in the heart and may lead to lipotoxic heart disease. Traditionally, the size of the cardiac triglyceride pool is thought to reflect the balance between uptake and beta-oxidation of fatty acids. However, triglycerides can also be exported from cardiomyocytes via secretion of apolipoproteinB-containing (apoB lipoproteins. Lipoprotein formation depends on expression of microsomal triglyceride transfer protein (MTP; the mouse expresses two isoforms of MTP, A and B. Since many aspects of the link between obesity-induced cardiac disease and cardiac lipid metabolism remain unknown, we investigated how cardiac lipoprotein synthesis affects cardiac expression of triglyceride metabolism-controlling genes, insulin sensitivity, and function in obese mice. Heart-specific ablation of MTP-A in mice using Cre-loxP technology impaired upregulation of MTP expression in response to increased fatty acid availability during fasting and fat feeding. This resulted in cardiac triglyceride accumulation but unaffected cardiac insulin-stimulated glucose uptake. Long-term fat-feeding of male C57Bl/6 mice increased cardiac triglycerides, induced cardiac expression of triglyceride metabolism-controlling genes and attenuated heart function. Abolishing cardiac triglyceride accumulation in fat-fed mice by overexpression of an apoB transgene in the heart prevented the induction of triglyceride metabolism-controlling genes and improved heart function. The results suggest that in obesity, the physiological increase of cardiac MTP expression serves to attenuate cardiac triglyceride accumulation albeit without major effects on cardiac insulin sensitivity. Nevertheless, the data suggest that genetically increased lipoprotein secretion prevents development of obesity-induced lipotoxic heart disease.

  3. Low Rates of Major Complications for Radiofrequency Ablation of Atrial Fibrillation Maintained Over 14 Years: A Single Centre Experience of 2750 Consecutive Cases.

    Science.gov (United States)

    Voskoboinik, Aleksandr; Sparks, Paul B; Morton, Joseph B; Lee, Geoffrey; Joseph, Stephen A; Hawson, Joshua J; Kistler, Peter M; Kalman, Jonathan M

    2018-02-03

    Despite technological advances, studies continue to report high complication rates for atrial fibrillation (AF) ablation. We sought to review complication rates for AF ablation at a high-volume centre over a 14-year period and identify predictors of complications. We reviewed prospectively collected data from 2750 consecutive AF ablation procedures at our institution using radiofrequency energy (RF) between January 2004 and May 2017. All cases were performed under general anaesthetic with transoesophageal echocardiography (TEE), 3D-mapping and an irrigated ablation catheter. Double transseptal puncture was performed under TEE guidance. All patients underwent wide antral circumferential isolation of the pulmonary veins (30W anteriorly, 25W posteriorly) with substrate modification at operator discretion. Of 2255 initial and 495 redo procedures, ablation strategies were: pulmonary vein isolation (PVI) only 2097 (76.3%), PVI+lines 368 (13.4%), PVI+posterior wall 191 (6.9%), PVI+cavotricuspid isthmus 277 (10.1%). There were 23 major (0.84%) and 20 minor (0.73%) complications. Cardiac tamponade (five cases - 0.18%) and phrenic nerve palsy (one case - 0.04%) rates were very low. Major vascular complications necessitating surgery or blood transfusion occurred in five patients (0.18%). There were no cases of death, permanent disability, atrio-oesophageal fistulae or symptomatic pulmonary vein (PV) stenosis, although there were five TEE probe-related complications (0.18%). Female gender (OR 2.14; 95% CI 1.07-4.26) but not age >70 (OR 1.01) was the only multivariate predictor of complications. Atrial fibrillation ablation performed at a high-volume centre using RF can be achieved with a low major complication rate in a representative AF population over a sustained period of time. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights

  4. Postnatal ablation of Foxm1 from cardiomyocytes causes late onset cardiac hypertrophy and fibrosis without exacerbating pressure overload-induced cardiac remodeling.

    Directory of Open Access Journals (Sweden)

    Craig Bolte

    Full Text Available Heart disease remains a leading cause of morbidity and mortality in the industrialized world. Hypertrophic cardiomyopathy is the most common genetic cardiovascular disorder and the most common cause of sudden cardiac death. Foxm1 transcription factor (also known as HFH-11B, Trident, Win or MPP2 plays an important role in the pathogenesis of various cancers and is a critical mediator of post-injury repair in multiple organs. Foxm1 has been previously shown to be essential for heart development and proliferation of embryonic cardiomyocytes. However, the role of Foxm1 in postnatal heart development and in cardiac injury has not been evaluated. To delete Foxm1 in postnatal cardiomyocytes, αMHC-Cre/Foxm1(fl/fl mice were generated. Surprisingly, αMHC-Cre/Foxm1(fl/fl mice exhibited normal cardiomyocyte proliferation at postnatal day seven and had no defects in cardiac structure or function but developed cardiac hypertrophy and fibrosis late in life. The development of cardiomyocyte hypertrophy and cardiac fibrosis in aged Foxm1-deficient mice was associated with reduced expression of Hey2, an important regulator of cardiac homeostasis, and increased expression of genes critical for cardiac remodeling, including MMP9, αSMA, fibronectin and vimentin. We also found that following aortic constriction Foxm1 mRNA and protein were induced in cardiomyocytes. However, Foxm1 deletion did not exacerbate cardiac hypertrophy or fibrosis following chronic pressure overload. Our results demonstrate that Foxm1 regulates genes critical for age-induced cardiomyocyte hypertrophy and cardiac fibrosis.

  5. Transesophageal NOTES--a critical analysis of relevant problems.

    Science.gov (United States)

    Grund, Karl E; Lehmann, Thorsten G

    2010-10-01

    The transesophageal access route has not become a principal topic in the discussion about NOTES up to now. Analyzing the problems in this new field of surgery, however, the transesophageal route shows high relevance. Here, all possibilities, limitations, and problems of NOTES become obvious. This paper contains a critical analysis of the literature published to date (nine full papers, five abstracts). Nearly all publications represent experimental studies in living pigs. In most cases a submucosal tunnel technique is performed as access route to mediastinum, pleural cavity, and heart. Interventions and operations include simple mediastinoscopies as well as epicardial operations after exposition of the heart. For access and manipulation, conventional flexible endoscopes and instruments are used. Clips, T-bars, or a combination of both achieve the closure. Some studies rely on spontaneous closure of the incision without any suturing or approximation. In such experimental settings, the following results are presented: Access is achieved in 90% of cases, the aim of the operation is met in 92%, technical success in closure is achieved in 90%, healing of incision assessed as good in two of five studies, satisfactory in three of five studies. Mortality, ranging from 6 to 25%, and complication rates were (surprisingly) high. It has to be stressed that analyzing these papers published to date, no adequate attention is paid to basic facts and problems of general and thoracic surgery (e.g. different forms, prevention, diagnosis and therapy of pneumothorax or differentiated forms of ventilation). Relevant differences in the anatomy and physiology of the esophagus and mediastinum between humans and pigs should additionally be taken into account to choose optimal experimental parameters when transferring results to human settings. Moreover, requirements regarding sterility and hygiene in a structure like the mediastinum, which is at high risk from the point of view of infection

  6. The effect of elastic modulus on ablation catheter contact area.

    Science.gov (United States)

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  7. Contemporary management of patients undergoing atrial fibrillation ablation: in-hospital and 1-year follow-up findings from the ESC-EHRA atrial fibrillation ablation long-term registry.

    Science.gov (United States)

    Arbelo, Elena; Brugada, Josep; Blomström-Lundqvist, Carina; Laroche, Cécile; Kautzner, Josef; Pokushalov, Evgeny; Raatikainen, Pekka; Efremidis, Michael; Hindricks, Gerhard; Barrera, Alberto; Maggioni, Aldo; Tavazzi, Luigi; Dagres, Nikolaos

    2017-05-01

    The ESC-EHRA Atrial Fibrillation Ablation Long-Term registry is a prospective, multinational study that aims at providing an accurate picture of contemporary real-world ablation for atrial fibrillation (AFib) and its outcome. A total of 104 centres in 27 European countries participated and were asked to enrol 20-50 consecutive patients scheduled for first and re-do AFib ablation. Pre-procedural, procedural and 1-year follow-up data were captured on a web-based electronic case record form. Overall, 3630 patients were included, of which 3593 underwent an AFib ablation (98.9%). Median age was 59 years and 32.4% patients had lone atrial fibrillation. Pulmonary vein isolation was attempted in 98.8% of patients and achieved in 95-97%. AFib-related symptoms were present in 97%. In-hospital complications occurred in 7.8% and one patient died due to an atrioesophageal fistula. One-year follow-up was performed in 3180 (88.6%) at a median of 12.4 months (11.9-13.4) after ablation: 52.8% by clinical visit, 44.2% by telephone contact and 3.0% by contact with the general practitioner. At 12-months, the success rate with or without antiarrhythmic drugs (AADs) was 73.6%. A significant portion (46%) was still on AADs. Late complications included 14 additional deaths (4 cardiac, 4 vascular, 6 other causes) and 333 (10.7%) other complications. AFib ablation in clinical practice is mostly performed in symptomatic, relatively young and otherwise healthy patients. Overall success rate is satisfactory, but complication rate remains considerable and a significant portion of patients remain on AADs. Monitoring after ablation shows wide variations. Antithrombotic treatment after ablation shows insufficient guideline-adherence. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  8. Atrioventricular node reentrant tachycardia (AVNRT) after mitral valvuloplasty during cardiac rehabilitation.

    Science.gov (United States)

    Fallavollita, Luca; Santillo, Elpidio; Marini, Luciano; Balestrini, Fabrizio

    2012-12-01

    We descrive a patient who presents palpitations during cardiac rehabilitation after mitral valvuloplasty. ECG showed regular narrow QRS tachycardia compatible with Atrioventricular Node Reentrant Tachycardia. After slow pathway radiofrequency catheter ablation, the patient completed the rehabilitation program remained tachycardia and palpitations-free.

  9. A new catheter design for combined radiofrequency ablation and optoacoustic treatment monitoring using copper-coated light-guides

    Science.gov (United States)

    Rebling, Johannes; Oyaga Landa, Francisco Javier; Deán-Ben, Xosé Luis; Razansky, Daniel

    2018-02-01

    Electrosurgery, i.e. the application of radiofrequency current for tissue ablation, is a frequently used treatment for many cardiac arrhythmias. Electrophysiological and anatomic mapping, as well as careful radiofrequency power control typically guide the radiofrequency ablation procedure. Despite its widespread application, accurate monitoring of the lesion formation with sufficient spatio-temporal resolution remains challenging with the existing imaging techniques. We present a novel integrated catheter for simultaneous radiofrequency ablation and optoacoustic monitoring of the lesion formation in real time and 3D. The design combines the delivery of both electric current and optoacoustic excitation beam in a single catheter consisting of copper-coated multimode light-guides and its manufacturing is described in detail. The electrical current causes coagulation and desiccation while the excitation light is locally absorbed, generating OA responses from the entire treated volume. The combined ablation-monitoring capabilities were verified using ex-vivo bovine tissue. The formed ablation lesions showed a homogenous coagulation while the ablation was monitored in realtime with a volumetric frame rate of 10 Hz over 150 seconds.

  10. Planning the Safety of Atrial Fibrillation Ablation Registry Initiative (SAFARI) as a Collaborative Pan-Stakeholder Critical Path Registry Model: a Cardiac Safety Research Consortium "Incubator" Think Tank.

    Science.gov (United States)

    Al-Khatib, Sana M; Calkins, Hugh; Eloff, Benjamin C; Packer, Douglas L; Ellenbogen, Kenneth A; Hammill, Stephen C; Natale, Andrea; Page, Richard L; Prystowsky, Eric; Jackman, Warren M; Stevenson, William G; Waldo, Albert L; Wilber, David; Kowey, Peter; Yaross, Marcia S; Mark, Daniel B; Reiffel, James; Finkle, John K; Marinac-Dabic, Danica; Pinnow, Ellen; Sager, Phillip; Sedrakyan, Art; Canos, Daniel; Gross, Thomas; Berliner, Elise; Krucoff, Mitchell W

    2010-01-01

    Atrial fibrillation (AF) is a major public health problem in the United States that is associated with increased mortality and morbidity. Of the therapeutic modalities available to treat AF, the use of percutaneous catheter ablation of AF is expanding rapidly. Randomized clinical trials examining the efficacy and safety of AF ablation are currently underway; however, such trials can only partially determine the safety and durability of the effect of the procedure in routine clinical practice, in more complex patients, and over a broader range of techniques and operator experience. These limitations of randomized trials of AF ablation, particularly with regard to safety issues, could be addressed using a synergistically structured national registry, which is the intention of the SAFARI. To facilitate discussions about objectives, challenges, and steps for such a registry, the Cardiac Safety Research Consortium and the Duke Clinical Research Institute, Durham, NC, in collaboration with the US Food and Drug Administration, the American College of Cardiology, and the Heart Rhythm Society, organized a Think Tank meeting of experts in the field. Other participants included the National Heart, Lung and Blood Institute, the Centers for Medicare and Medicaid Services, the Agency for Healthcare Research and Quality, the Society of Thoracic Surgeons, the AdvaMed AF working group, and additional industry representatives. The meeting took place on April 27 to 28, 2009, at the US Food and Drug Administration headquarters in Silver Spring, MD. This article summarizes the issues and directions presented and discussed at the meeting. Copyright 2010 Mosby, Inc. All rights reserved.

  11. Radiotherapy beyond cancer: Target localization in real-time MRI and treatment planning for cardiac radiosurgery

    International Nuclear Information System (INIS)

    Ipsen, S.; Blanck, O.; Rades, D.; Oborn, B.; Bode, F.; Liney, G.; Hunold, P.; Schweikard, A.; Keall, P. J.

    2014-01-01

    Purpose: Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefits of margin reduction assuming real-time motion compensation was applied. Methods: For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. Results: Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior–inferior), 2.4 mm (anterior–posterior), and 2 mm (left–right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the

  12. Radiotherapy beyond cancer: Target localization in real-time MRI and treatment planning for cardiac radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Ipsen, S. [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Sydney, New South Wales 2006, Australia and Institute for Robotics and Cognitive Systems, University of Luebeck, Luebeck 23562 (Germany); Blanck, O.; Rades, D. [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck, Luebeck 23562 (Germany); Oborn, B. [Illawarra Cancer Care Centre (ICCC), Wollongong, New South Wales 2500, Australia and Centre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, New South Wales 2500 (Australia); Bode, F. [Medical Department II, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck, Luebeck 23562 (Germany); Liney, G. [Ingham Institute for Applied Medical Research, Liverpool Hospital, Liverpool, New South Wales 2170 (Australia); Hunold, P. [Department of Radiology and Nuclear Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck, Luebeck 23562 (Germany); Schweikard, A. [Institute for Robotics and Cognitive Systems, University of Luebeck, Luebeck 23562 (Germany); Keall, P. J., E-mail: paul.keall@sydney.edu.au [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Sydney, New South Wales 2006 (Australia)

    2014-12-15

    Purpose: Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefits of margin reduction assuming real-time motion compensation was applied. Methods: For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. Results: Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior–inferior), 2.4 mm (anterior–posterior), and 2 mm (left–right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the

  13. Radiotherapy beyond cancer: target localization in real-time MRI and treatment planning for cardiac radiosurgery.

    Science.gov (United States)

    Ipsen, S; Blanck, O; Oborn, B; Bode, F; Liney, G; Hunold, P; Rades, D; Schweikard, A; Keall, P J

    2014-12-01

    Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefits of margin reduction assuming real-time motion compensation was applied. For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior-inferior), 2.4 mm (anterior-posterior), and 2 mm (left-right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the ideal scenario, compromising

  14. Rotational Angiography Based Three-Dimensional Left Atrial Reconstruction: A New Approach for Transseptal Puncture.

    Science.gov (United States)

    Koektuerk, Buelent; Yorgun, Hikmet; Koektuerk, Oezlem; Turan, Cem H; Gorr, Eduard; Horlitz, Marc; Turan, Ramazan G

    2016-02-01

    Rotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. We included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). The mean age of the study population was 61 ± 10 years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 ± 825.3 μGym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 ± 5.5 min. TSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure. © 2015 John Wiley & Sons Ltd.

  15. Prosthetic tricuspid valve dysfunction assessed by three-dimensional transthoracic and transesophageal echocardiography.

    Science.gov (United States)

    Yuasa, Toshinori; Takasaki, Kunitsugu; Mizukami, Naoko; Ueya, Nami; Kubota, Kayoko; Horizoe, Yoshihisa; Chaen, Hideto; Kuwahara, Eiji; Kisanuki, Akira; Hamasaki, Shuichi

    2013-09-01

    A 39-year-old male who had undergone tricuspid valve replacement for severe tricuspid regurgitation was admitted with palpitation and general edema. Two-dimensional (2D) echocardiography showed tricuspid prosthetic valve dysfunction. Additional three-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) could clearly demonstrate the disabilities of the mechanical tricuspid valve. Particularly, 3D TEE demonstrated a mass located on the right ventricular side of the tricuspid prosthesis, which may have caused the stuck disk. This observation was confirmed by intra-operative findings.

  16. Dose-Escalation Study for Cardiac Radiosurgery in a Porcine Model

    Energy Technology Data Exchange (ETDEWEB)

    Blanck, Oliver, E-mail: oliver.blanck@uksh.de [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); CyberKnife Center Northern Germany, Guestrow (Germany); Bode, Frank [Medical Department II, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Gebhard, Maximilian [Institute of Pathology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Hunold, Peter [Department of Radiology and Nuclear Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Brandt, Sebastian [Department of Anaesthesiology and Intensive Care Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Bruder, Ralf [Institute for Robotics and Cognitive Systems, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Grossherr, Martin [Department of Anaesthesiology and Intensive Care Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Vonthein, Reinhard [Institute of Medical Biometry and Statistics, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Rades, Dirk [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Dunst, Juergen [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); University Copenhagen (Denmark)

    2014-07-01

    Purpose: To perform a proof-of-principle dose-escalation study to radiosurgically induce scarring in cardiac muscle tissue to block veno-atrial electrical connections at the pulmonary vein antrum, similar to catheter ablation. Methods and Materials: Nine mini-pigs underwent pretreatment magnetic resonance imaging (MRI) evaluation of heart function and electrophysiology assessment by catheter measurements in the right superior pulmonary vein (RSPV). Immediately after examination, radiosurgery with randomized single-fraction doses of 0 and 17.5-35 Gy in 2.5-Gy steps were delivered to the RSPV antrum (target volume 5-8 cm{sup 3}). MRI and electrophysiology were repeated 6 months after therapy, followed by histopathologic examination. Results: Transmural scarring of cardiac muscle tissue was noted with doses ≥32.5 Gy. However, complete circumferential scarring of the RSPV was not achieved. Logistic regressions showed that extent and intensity of fibrosis significantly increased with dose. The 50% effective dose for intense fibrosis was 31.3 Gy (odds ratio 2.47/Gy, P<.01). Heart function was not affected, as verified by MRI and electrocardiogram evaluation. Adjacent critical structures were not damaged, as verified by pathology, demonstrating the short-term safety of small-volume cardiac radiosurgery with doses up to 35 Gy. Conclusions: Radiosurgery with doses >32.5 Gy in the healthy pig heart can induce circumscribed scars at the RSPV antrum noninvasively, mimicking the effect of catheter ablation. In our study we established a significant dose-response relationship for cardiac radiosurgery. The long-term effects and toxicity of such high radiation doses need further investigation in the pursuit of cardiac radiosurgery for noninvasive treatment of atrial fibrillation.

  17. Towards optical spectroscopic anatomical mapping (OSAM) for lesion validation in cardiac tissue (Conference Presentation)

    Science.gov (United States)

    Singh-Moon, Rajinder P.; Zaryab, Mohammad; Hendon, Christine P.

    2017-02-01

    Electroanatomical mapping (EAM) is an invaluable tool for guiding cardiac radiofrequency ablation (RFA) therapy. The principle roles of EAM is the identification of candidate ablation sites by detecting regions of abnormal electrogram activity and lesion validation subsequent to RF energy delivery. However, incomplete lesions may present interim electrical inactivity similar to effective treatment in the acute setting, despite efforts to reveal them with pacing or drugs, such as adenosine. Studies report that the misidentification and recovery of such lesions is a leading cause of arrhythmia recurrence and repeat procedures. In previous work, we demonstrated spectroscopic characterization of cardiac tissues using a fiber optic-integrated RF ablation catheter. In this work, we introduce OSAM (optical spectroscopic anatomical mapping), the application of this spectroscopic technique to obtain 2-dimensional biodistribution maps. We demonstrate its diagnostic potential as an auxiliary method for lesion validation in treated swine preparations. Endocardial lesion sets were created on fresh swine cardiac samples using a commercial RFA system. An optically-integrated catheter console fabricated in-house was used for measurement of tissue optical spectra between 600-1000nm. Three dimensional, Spatio-spectral datasets were generated by raster scanning of the optical catheter across the treated sample surface in the presence of whole blood. Tissue optical parameters were recovered at each spatial position using an inverse Monte Carlo method. OSAM biodistribution maps showed stark correspondence with gross examination of tetrazolium chloride stained tissue specimens. Specifically, we demonstrate the ability of OSAM to readily distinguish between shallow and deeper lesions, a limitation faced by current EAM techniques. These results showcase the OSAMs potential for lesion validation strategies for the treatment of cardiac arrhythmias.

  18. Detection of patent ductus arteriosus with intraoperative transesophageal echocardiography in a patient undergoing closure of coronary artery to pulmonary artery fistula.

    Science.gov (United States)

    Miyata, Yuka; Hayashi, Yukio

    2017-01-01

    Coronary artery to pulmonary artery fistula is an unusual vascular anomaly, and the shunt ratio of this fistula is usually small. We report anesthetic management of a 55-year-old female with annuloaortic ectasia, aortic valve regurgitation, and coronary artery to pulmonary artery fistula undergoing radical repair. We calculated the left-to-right shunt ratio after placement of a pulmonary artery catheter and found that the ratio was unexpectedly high. Thus, we explored the presence of another shunt by intraoperative transesophageal echocardiography and found patent ductus arteriosus undiagnosed before operation. A combination of a pulmonary artery catheter and transesophageal echocardiography is useful to explore the presence of another shunt, such as patent ductus arteriosus during anesthesia.

  19. Diagnostic value of transesophageal atrial pacing myocardial perfusion imaging in coronary artery disease

    International Nuclear Information System (INIS)

    Jia Yongping; Li Zhiling; Li Yunqian

    1994-01-01

    Transesophageal atrial pacing (TAP) SPECT myocardial perfusion imaging (MPI) with 99m Tc-MIBI was performed in 46 patients with coronary artery disease (CAD) and 15 normal subjects. The results were compared with exercise SPECT MPI. The results showed that the sensitivity and specificity of TAP SPECT to evaluate CAD were 86,96% and 93.33%. TAP SPECT MPI had a significant correlation with exercise SPECT MPI to detect ischemic segment of CAD (r = 0.95)

  20. Catheter Ablation of Atrial Fibrillation in Patients with Hardware in the Heart - Septal Closure Devices, Mechanical Valves and More.

    Science.gov (United States)

    Bartoletti, Stefano; Santangeli, Pasquale; DI Biase, Luigi; Natale, Andrea

    2013-01-01

    Patients with mechanical "hardware" in the heart, such as those with mechanical cardiac valves or atrial septal closure devices, represent a population at high risk of developing AF. Catheter ablation of AF in these subjects might represent a challenge, due to the perceived higher risk of complications associated with the presence of intracardiac mechanical devices. Accordingly, such patients were excluded or poorly represented in major trials proving the benefit of catheter ablation for the rhythm-control of AF. However, recent evidence supports the concept that catheter ablation procedures might be equally effective in these patients, without a significant increase in the risk of procedural complications. This review will summarize the current state-of-the-art on catheter ablation of AF in patients with mechanical "hardware" in the heart.

  1. [Evaluation of the radiofrequency ablation effectiveness in patients with the Wolff-Parkinson-White syndrome].

    Science.gov (United States)

    Ushakov, I B; Ardashev, A V; Ardashev, V N; Voronkov, Iu I; Sharoĭko, M V; Akimova, O S

    2012-01-01

    A one-year prospective study involved 22 patients with the Wolff-Parkinson-White syndrome (WPW) and 20 healthy people. Means age of patients was 34.3 +/- 16.3 years. All 22 patients were successfully treated with radiofrequency ablation (RFA) of additional pathways. RFA effectiveness was evaluated with the help of clinical questionnaire, data of ECG, EchoCG, heart rate variability (HRV), frequency response and nonlinear dynamics. Cardiac rhythm disturbances were verified using Holter monitoring applied to all patients. Positive clinical effect was achieved in all the WPW patients, as RFA arrested cardiac arrhythmias completely. Holter monitoring did not register cardiac disturbances which points to high RFA effectiveness in WPW patients. HRV, frequency response and nonlinear dynamics reassumed their normal patterns.

  2. Integration of cardiac computed tomography into pulmonary vein isolation in patients with paroxysmal atrial fibrillation

    International Nuclear Information System (INIS)

    Weber, T.F.; Klemm, H.; Willems, S.; Koops, A.; Adam, G.; Begemann, P.G.; Nagel, H.D.

    2007-01-01

    Purpose: Detailed anatomic information of the left atrium is necessary for securely performing radiofrequency ablation of atrial fibrillation-triggering ectopies in the pulmonary vein ostia. In this study the impact of a preinterventionally acquired cardiac computed tomography (CT) on pulmonary vein isolation (PVI) was assessed. Materials and methods: Examinations of 54 patients with paroxysmal atrial fibrillation undergoing PVI were analyzed. In 27 patients a supplementary cardiac CT was obtained prior to PVI (CT group, 12 women, 15 men, 59.7 ± 9.9 years of age): 16 x 1.5 mm collimation, 0.2 pitch, 120 kV tube voltage, 400 effective mAs. The fluoroscopy time, effective dose and quantity of radiofrequency (RF) pulses of the following catheter ablation were compared to 27 patients undergoing stand-alone PVI (11 women, 16 men, 62.0 ± 9.9 years of age). Mann-Whitney tests served for statistical comparison. Results: CT datasets were successfully integrated into the ablation procedure of each patient in the CT group. The mean quantity of RF pulses was significantly lower in the CT group (22.1 ± 8.0 vs. 29.1 ± 11.9, p = 0.030), and a significant reduction of fluoroscopy time was found (41.8 ± 12.0 min vs. 51.2 ± 16.0 min, p = 0.005). Effective doses of the catheter ablation differed in an equivalent dimension but altogether not significantly (14.9 ± 10.0 mSv vs. 20.0 ± 16.0 mSv, p = 0.203). The mean additive effective dose of the cardiac CT was 85 ± 0.3 mSv. (orig.)

  3. Neurohumoral indicators of efficacy radiofrequency cardiac denervation

    Energy Technology Data Exchange (ETDEWEB)

    Evtushenko, A. V., E-mail: ave@cardio-tomsk.ru; Evtushenko, V. V. [National Research Tomsk State University, Tomsk (Russian Federation); Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Saushkina, Yu. V.; Gusakova, A. M.; Suslova, T. E.; Dymbrylova, O. N.; Smyshlyaev, K. A.; Kurlov, I. O. [Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Lishmanov, Yu. B.; Anfinogenova, Ya. D. [National Research Tomsk Polytechnic University, Tomsk (Russian Federation); Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Sergeevichev, D. S. [Academician E.N. Meshalkin State Research Institute of Circulation Pathology, Novosibirsk (Russian Federation); Bykov, A. N.; Syryamkin, V. I.; Kistenev, Yu. V. [National Research Tomsk State University, Tomsk (Russian Federation); Lotkov, A. I. [Institute of Strength Physics and Materials Science of the Siberian Branch of the RAS, Tomsk (Russian Federation); Pokushalov, E. A.

    2015-11-17

    In this study, we compared pre- and postoperative parameters of the cardiac sympathetic innervation. The aim of the study was to examine the approaches to evaluating the quality of radiofrequency (RF)-induced cardiac denervation by using non-invasive and laboratory methods. The study included 32 people with long-lasting persistent atrial fibrillation (AF). The patients were divided into 2 groups according to the objectives of the study: group 1 (main) - 21 patients with mitral valve diseases, which simultaneously with radiofrequency ablation (RFA) AF carried out on the effects of the paraganglionic nervous plexuses by C. Pappone (2004) and N. Doll (2008) schemes. The second group (control) contained 11 patients with heart diseases in sinus rhythm (the RF denervation not been performed). All patients, who underwent surgical treatment, were received examination of cardiac sympathetic tone by using {sup 123}I-MIBG. All of them made blood analysis from ascending aorta and coronary sinus to determine the level of norepinephrine and its metabolites before and after cardiac denervation. Data of radionuclide examination are correlating with laboratory data.

  4. Catheter ablation for the treatment of electrical storm in patients with implantable cardioverter-defibrillators: short- and long-term outcomes in a prospective single-center study.

    Science.gov (United States)

    Carbucicchio, Corrado; Santamaria, Matteo; Trevisi, Nicola; Maccabelli, Giuseppe; Giraldi, Francesco; Fassini, Gaetano; Riva, Stefania; Moltrasio, Massimo; Cireddu, Manuela; Veglia, Fabrizio; Della Bella, Paolo

    2008-01-29

    Electrical storm (ES) caused by recurrent episodes of ventricular tachycardia (VT) can cause sudden death in patients with implantable cardioverter-defibrillators and adversely affects prognosis in survivors. Catheter ablation has been proposed for treating ES, but its long-term effect in a large population has never been verified. Ninety-five consecutive patients with coronary artery disease (72 patients), idiopathic dilated cardiomyopathy (10 patients), and arrhythmogenic right ventricular dysplasia/cardiomyopathy (13 patients) undergoing catheter ablation for drug-refractory ES were prospectively evaluated. Short-term efficacy was defined by a complete protocol of programmed electric stimulation and by in-hospital outcome; long-term analysis addressed ES recurrence, cardiac mortality, and VT recurrence. Pleomorphic/nontolerated VTs required electroanatomic and noncontact mapping in 48 and 22 patients, respectively, and percutaneous cardiopulmonary support in 10 patients. An epicardial approach was used in 10 patients. After 1 to 3 procedures, induction of any clinical VT(s) by programmed electrical stimulation was prevented in 85 patients (89%). ES was acutely suppressed in all patients; a minimum period of 7 days with stable rhythm was required before hospital discharge. At a median follow-up of 22 months (range, 1 to 43 months), 87 patients (92%) were free of ES and 63 patients (66%) were free of VT recurrence. Eight of 10 patients with persistent inducibility of clinical VT(s) had ES recurrence; 4 of them died suddenly despite appropriate implantable cardioverter-defibrillator intervention. All together, 11 of 95 patients (12%) died of cardiac-related reasons. In the group of patients presenting with all clinical VTs acutely abolished, no ES recurrence was documented, and cardiac mortality was significantly lower compared with the group of patients showing > or = 1 clinical VT still inducible after catheter ablation. Advanced strategies of catheter ablation

  5. Interest of non-invasive and semi-invasive testings in asymptomatic children with pre-excitation syndrome.

    Science.gov (United States)

    Brembilla-Perrot, B; Chometon, F; Groben, L; Ammar, S; Bertrand, J; Marcha, C; Cloez, J L; Tisserand, A; Huttin, O; Tatar, C; Duhoux, F; Yangni N'da, O; Beurrier, D; Terrier de Chaise, A; Zhang, N; Abbas, M; Cedano, J; Marçon, F

    2007-09-01

    To determine the feasibility and the results of exercise testing (ET) and electrophysiological study (EPS) in outpatient asymptomatic children with a Wolff-Parkinson-White (WPW) syndrome. Exercise testing and transesophageal EPS were performed in 55 outpatient asymptomatic children aged 6 to 19 years old (14 +/- 3) with WPW. Wolff-Parkinson-White persisted during maximal exercise. Isoproterenol was not required in five children younger than 10 years old, because they developed a catecholaminergic sinus tachycardia. Maximal rate conducted through accessory pathway (AP) was higher in children younger than 16 years old than in teenagers (P < 0.05). Atrioventricular re-entrant tachycardia (AVRT) was induced in six children; atrial fibrillation (AF) in 12 children. The induction of tachycardias and the dangerous forms (18%) were not influenced by age. After 5 +/- 1 years, one child, 12 year old with inducible rapid AF, had a sudden cardiac arrest; two children became symptomatic after ablation. Transesophageal EPS was required to determine the prognosis of asymptomatic WPW in children. The maximal rate conducted in AP was higher in children younger than 16 years old than in teenagers; other data did not differ. AVRT was rare; 71% of children had no inducible arrhythmia and were authorized to resume physical activities.

  6. Radiofrequency ablation of neuroendocrine liver metastases: the Middlesex experience.

    Science.gov (United States)

    Gillams, A; Cassoni, A; Conway, G; Lees, W

    2005-01-01

    Current treatment options for neuroendocrine liver metastases are not widely applicable or not that effective. Image-guided thermal ablation offers the possibility of a minimally invasive, albeit palliative, treatment that decreases tumor volume, preserves most of the normal liver, and can be repeated several times. We report our experience with image-guided thermal ablation in 25 patients with unresectable liver metastases. Since 1990 we have treated 189 tumors at 66 treatment sessions in 25 patients (12 female, 13 male; median age, 56 years; age range, 26--78 years). Thirty treatments were performed with a solid-state laser, and 36 treatments were performed with radiofrequency ablation. All but one treatment was performed percutaneously under image guidance. Sixteen patients had metastases from carcinoid primaries, three from gastrinoma, two from insulinoma, and four from miscellaneous causes. Fourteen of 25 had symptoms from hormone secretion. Imaging follow-up was available in 19 patients at a median of 21 months (range, 4--75 months). There was a complete response in six patients, a partial response in seven, and stable disease in one; hence, tumor load was controlled in 14 of 19 patients (74%). Relief of hormone-related symptoms was achieved in nine of 14 patients (69%). The median survival period from the diagnosis of liver metastases was 53 months. One patient with end-stage cardiac disease died after a carcinoid crisis. There were eight (12%) complications: five local and three distant, four major and four minor. As a minimally invasive, readily repeatable procedure that can be used to ablate small tumors, preferably before patients become severely symptomatic, radiofrequency ablation can provide effective control of liver tumor volume in most patients over many years.

  7. Coi-wiz: An interactive computer wizard for analyzing cardiac optical signals.

    Science.gov (United States)

    Yuan, Xiaojing; Uyanik, Ilyas; Situ, Ning; Xi, Yutao; Cheng, Jie

    2009-01-01

    A number of revolutionary techniques have been developed for cardiac electrophysiology research to better study the various arrhythmia mechanisms that can enhance ablating strategies for cardiac arrhythmias. Once the three-dimensional high resolution cardiac optical imaging data is acquired, it is time consuming to manually go through them and try to identify the patterns associated with various arrhythmia symptoms. In this paper, we present an interactive computer wizard that helps cardiac electrophysiology researchers to visualize and analyze the high resolution cardiac optical imaging data. The wizard provides a file interface that accommodates different file formats. A series of analysis algorithms output waveforms, activation and action potential maps after spatial and temporal filtering, velocity field and heterogeneity measure. The interactive GUI allows the researcher to identify the region of interest in both the spatial and temporal domain, thus enabling them to study different heart chamber at their choice.

  8. Treatment of Atrial Fibrillation in Elderly Patients with the Cox Maze Procedure Concurrently with Other Cardiac Operations

    Directory of Open Access Journals (Sweden)

    Ja Hong Kuh

    2017-06-01

    Full Text Available Background: In elderly patients who have atrial fibrillation (AF, surgical ablation of the arrhythmia during cardiac surgery may be challenging. Despite the reported advantages of ablating AF with the Cox maze procedure (CMP, the addition of the CMP may complicate other cardiac operations. We evaluated the effect of the CMP in elderly patients concurrent with other cardiac operations. Methods: From October 2007 to December 2015, we enrolled 27 patients aged >70 years who had AF and who underwent the CMP concurrently with other cardiac operations. The mean preoperative additive European System for Cardiac Operative Risk Evaluation score was 8±11 (high risk. Results: Only 1 hospital death occurred (4%. The Kaplan-Meier method showed a high 5‐year cumulative survival rate (92%. At mean follow‐up of 51 months, 23 patients (89% had sinus rhythm conversion. The postoperative left atrial dimensions did not significantly differ between the 8 patients who had reduction plasty for giant left atrium (53.4±7.5 cm and the 19 patients who did not have reduction plasty (48.7±5.7 cm. Conclusion: In patients aged >70 years, concurrent CMP may be associated with a high rate of sinus rhythm conversion without increased surgical risk, despite the added complexity of the main cardiac procedure.

  9. Radiofrequency ablation of atrial tachyarrhythmias in adults with tetralogy of Fallot - predictors of success and outcome.

    Science.gov (United States)

    Ezzat, Vivienne A; Ryan, Matthew J; O'Leary, Justin; Ariti, Cono; Deanfield, John; Pandya, Bejal; Cullen, Shay; Walker, Fiona; Khan, Fakhar; Abrams, Dominic J; Lambiase, Pier D; Lowe, Martin D

    2017-03-01

    Adults with tetralogy of Fallot experience atrial tachyarrhythmias; however, there are a few data on the outcomes of radiofrequency ablation. We examined the characteristics, outcome, and predictors of recurrence of atrial tachyarrhythmias after radiofrequency ablation in tetralogy of Fallot patients. Methods/results Retrospective data were collected from 2004 to 2013. In total, 56 ablations were performed on 37 patients. We identified two matched controls per case: patients with tetralogy of Fallot but no radiofrequency ablation and not known to have atrial tachyarrhythmias. Acute success was 98%. Left atrial arrhythmias increased in frequency over time. The mean follow-up was 41 months; 78% were arrhythmia-free. Number of cardiac surgeries, age, and presence of atrial fibrillation were predictors of recurrence. Lone cavo-tricuspid isthmus-dependent flutter reduced the likelihood of atrial fibrillation. Right and left atria in patients with tetralogy of Fallot were larger in ablated cases than controls. NYHA class was worse in cases and improved after ablation; baseline status predicted death. Of matched non-ablated controls, a number of them had atrial fibrillation. These patients were excluded from the case-control study but analysed separately. Most of them had died during follow-up, whereas of the matched ablated cases all were alive and the majority in sinus rhythm. Patients with tetralogy of Fallot and atrial tachyarrhythmias have more dilated atria than those without atrial tachyarrhythmias. Radiofrequency ablation improves functional status. Left atrial ablation is more commonly required with repeat procedures. There is a high prevalence of atrial tachyarrhythmias, particularly atrial fibrillation, in patients with tetralogy of Fallot; early radiofrequency ablation may have a protective effect against this.

  10. Hemodynamic Change in Pulmonary Vein Stenosis after Radiofrequency Ablation: Assessment with Magnetic Resonance Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Doyoung; Jung, Jung Im; Oh, Yong Seog; Youn, Ho Joong [Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2012-11-15

    We present a case of pulmonary vein (PV) stenosis after radio-frequency (RF) ablation, in which a hemodynamic change in the pulmonary artery was similar to that of congenital PV atresia on time-resolved contrast-enhanced magnetic resonance angiography (TR-MRA). A 48-year-old man underwent RF ablation due to atrial fibrillation. The patient subsequently complained of hemoptysis, dyspnea on exertion, and right chest pain. Right PV stenosis after catheter ablation was diagnosed through chest computed tomography and lung perfusion scan. Pulmonary TR-MRA revealed the pulmonary artery via systemic arterial collaterals and draining systemic collateral veins. On a velocity-encoded cine image, the flow direction of the right pulmonary artery was reversed in the diastolic phase and the left pulmonary artery demonstrated continuous forward flow throughout the cardiac cycle. These hemodynamic changes were similar to those seen in congenital unilateral PV atresia.

  11. Lesion size in relation to ablation site during radiofrequency ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, A

    1998-01-01

    This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation was perfor......This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation...... was performed during two different flow-velocities in a tissue bath, while electrode contact pressure and position were unchanged. Target temperature was 80 degrees C. Obtained tip temperature, power consumption and lesion dimensions were measured. In vivo lesion volume, depth and width were found significantly.......61 in vitro). We conclude that during temperature controlled radiofrequency ablation lesion size differs for septal and apical left ventricular applications. Differences in convective cooling might play an important role in this respect. This is supported by our in vitro experiments, where increased...

  12. Fluoroscopic position of the second-generation cryoballoon during ablation in the right superior pulmonary vein as a predictor of phrenic nerve injury.

    Science.gov (United States)

    Saitoh, Yukio; Ströker, Erwin; Irfan, Ghazala; Mugnai, Giacomo; Ciconte, Giuseppe; Hünük, Burak; Velagić, Vedran; Overeinder, Ingrid; Tanaka, Kaoru; Brugada, Pedro; de Asmundis, Carlo; Chierchia, Gian-Battista

    2016-08-01

    Phrenic nerve injury (PNI) is the most frequently observed complication during pulmonary vein isolation procedure using the second-generation cryoballoon (CB). Our objective was to analyse the correlation between the fluoroscopic position of the 28 mm CB during ablation in the right superior pulmonary vein (RSPV) and the occurrence of PNI. A total of 165 patients having undergone the large 28 mm CB ablation were retrospectively reviewed. Positioning of the CB relative to the cardiac silhouette was classified under fluoroscopic guidance in antero-posterior projection during RSPV ablation. Regarding the lower half of the balloon, CB positioning was defined as follows: (A) completely inside the cardiac shadow; (B1) Phrenic nerve injury occurred in 9.7% (16/165) during ablation in the RSPV. The occurrence of PNI was 0.9, 10.6, and 90.1% in positions A, B1, and B2, respectively (A vs. B1, P = 0.01; B1 vs. B2, P < 0.0001). Among other pre-procedural and procedural variables, the B2 position was the strongest independent determinant for predicting PNI at RSPV (P = 0.001, odds ratio: 119.9; 95% confidence interval: 11.6-1234.7) after multivariable analysis. The incidence of PNI at the RSPV significantly increased in case of more distal positioning of the CB relative to the cardiac shadow. This simple and straightforward intra-procedural indicator might prone the operators to attempt occluding the RPSV more proximally in order to avoid PNI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  13. The clinical significance of perivalvular pannus in prosthetic mitral valves: Can cardiac CT be helpful?

    Science.gov (United States)

    Chang, Suyon; Suh, Young Joo; Han, Kyunghwa; Kim, Jin Young; Kim, Young Jin; Chang, Byung-Chul; Choi, Byoung Wook

    2017-12-15

    The clinical significance of pannus in the prosthetic mitral valve (MV) is not well documented. To investigate the clinical significance of pannus on cardiac computed tomography (CT) in patients with a prosthetic MV. A total of 130 patients with previous MV replacement who underwent cardiac CT were retrospectively included in this study. The presence of pannus, paravalvular leak (PVL) around the prosthetic MV and limitation of motion (LOM) of the MV were analyzed using CT. Between patients with MV pannus and those without pannus, CT, echocardiographic, and redo-surgery findings were compared. The diagnostic performance of CT and transesophageal echocardiography (TEE) for the detection of MV pannus was also compared, using surgical findings as a standard reference. MV pannus was observed on cardiac CT in 32.3% of the study population. Patients with MV pannus detected on CT more commonly had LOM (28.2% vs. 15.2%) and less frequently had PVL of the prosthetic MV (16.7% vs. 25%) than patients without MV pannus (P>0.05). Prosthetic valve obstruction (PVO) due prosthetic MV pannus requiring redo-surgery was present in only five patients (11.9%). Cardiac CT detected MV pannus with sensitivity of 65.2% and specificity of 80.9% and showed better diagnostic performance than TEE (Ppannus can frequently be seen on cardiac CT. However, its clinical significance should be assessed with careful consideration, because PVO due to MV pannus is relatively uncommon, and pannus can be seen in patients without any clinical problems. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Therapeutic efficacy of percutaneous radiofrequency ablation versus microwave ablation for hepatocellular carcinoma.

    Directory of Open Access Journals (Sweden)

    Lei Zhang

    Full Text Available The aim of this study was to investigate the therapeutic efficacy of percutaneous radiofrequency (RF ablation versus microwave (MW ablation for hepatocellular carcinoma (HCC measuring ≤ 5 cm in greatest diameter. From January 2006 to December 2006, 78 patients had undergone RF ablation whereas 77 had undergone MW ablation. Complete ablation (CA, local tumour progression (LTP and distant recurrence (DR were compared. The overall survival curves were calculated with the Kaplan-Meier technique and compared with the log-rank test. The CA rate was 83.4% (78/93 for RF ablation and 86.7%(91/105 for MW ablation. The LTP rate was 11.8% (11/93 for RF ablation and 10.5% (11/105 for MW ablation. DR was found in 51 (65.4% in the RF ablation and 62 (80.5% in the MW ablation. There was no significant difference in the 1-, 3-, and 5-year overall survival rates (P = 0.780 and the 1-, 3-, and 5-year disease-free survival rates (P = 0.123 between RF and MW ablation. At subgroup analyses, for patients with tumors ≤ 3.0 cm, there was no significant difference in the 1-, 3-, and 5-year overall survival rates (P = 0.067 and the corresponding disease-free survival rates(P = 0.849. For patients with tumor diameters of 3.1-5.0 cm, the 1-, 3-, and 5-year overall survival rates were 87.1%, 61.3%, and 40.1% for RF ablation and 85.4%, 36.6%, and 22% for MW ablation, with no significant difference (P = 0.068. The corresponding disease-free survival rates were 74.2%, 54.8%, and 45.2% for the RF ablation group and 53.3%, 26.8%, and 17.1% for the MW ablation group. The disease-free survival curve for the RF ablation group was significantly better than that for the MW ablation group (P = 0.018. RF ablation and MW ablation are both effective methods in treating hepatocellular carcinomas, with no significant differences in CA, LTP, DR, and overall survival.

  15. Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves.

    Science.gov (United States)

    Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M

    2008-12-01

    Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.

  16. Microwave Ablation of Lung Tumors Near the Heart: A Retrospective Review of Short-Term Procedural Safety in Ten Patients.

    Science.gov (United States)

    Maxwell, Aaron W P; Healey, Terrance T; Dupuy, Damian E

    2017-09-01

    To evaluate the rate of short-term complications associated with microwave ablation of lung tumors located near the heart. This HIPAA-compliant study was performed with a waiver for informed consent. Patients who underwent microwave ablation of lung tumors located 10 mm or less from the heart were identified by retrospective chart review. Both primary and metastatic tumors were included. Only tumors directly adjacent to one of the four cardiac chambers were included. All patients were treated in a single session using CT guidance with continuous electrocardiographic monitoring. Rates of new-onset arrhythmia and myocardial infarction (MI) within 90 days of the procedure were quantified, and evidence of cardiac or pericardiac injury was assessed for using post-ablation contrast-enhanced chest CT, electrocardiography (EKG), and-when available-echocardiography. Complications were graded using the Common Terminology Criteria for Adverse Events (CTCAE) system. Ten patients (four males, six females; mean age 73.1 ± 9.5 years) met all inclusion criteria. Mean tumor distance from the heart was 3 mm (range, 0-6 mm). New-onset arrhythmia was not observed during or following any of the microwave ablation treatments, and there were no documented 90-day MI events. CTCAE Grade 1 complications were observed by CT in eight patients, most commonly mild focal pericardial thickening. EKG and echocardiography were normal in all patients. No major complications (CTCAE Grade 3 or greater) were observed. Microwave ablation of lung tumors located 10 mm or less from the heart appears to have low associated short-term morbidity and may be appropriate in selected patients.

  17. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.

    Science.gov (United States)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F; Winther-Jensen, Matilde; Nilsson, Jens C; Kjaergaard, Jesper; Møller-Sørensen, Hasse

    2018-01-09

    Estimation of cardiac output (CO) is essential in the treatment of circulatory unstable patients. CO measured by pulmonary artery catheter thermodilution is considered the gold standard but carries a small risk of severe complications. Stroke volume and CO can be measured by transesophageal echocardiography (TEE), which is widely used during cardiac surgery. We hypothesized that Doppler-derived CO by 3-dimensional (3D) TEE would agree well with CO measured with pulmonary artery catheter thermodilution as a reference method based on accurate measurements of the cross-sectional area of the left ventricular outflow tract. The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias (mean difference between methods), limits of agreement (equal to bias ± 2 standard deviations of the bias), and percentage error (limits of agreement divided by the mean of the 2 methods). Precision was determined for the individual methods (equal to 2 standard deviations of the bias between replicate measurements) to determine the acceptable limits of agreement. We found a good precision for Doppler-derived CO measured by 3D TEE, but although the bias for Doppler-derived CO by 3D compared to

  18. Role of Electrophysiological Study and Catheter Ablation for Recurrent Ventricular Tachycardia Complicating Myocarditis

    Directory of Open Access Journals (Sweden)

    Emanuele Cecchi

    2012-01-01

    Full Text Available Here we report the case of a 31-year-old man admitted to our hospital with echocardiografic and Cardiac Magnetic Resonance signs of myocarditis complicated by ventricular tachycardia, initially resolved with direct current shock. After the recurrence of ventricular tachycardia the patient was submitted to electrophysiological study revealing a re-entrant circuit at the level of the medium segment of interventricular septum, successfully treated with transcatheter ablation. This case highlights how the presence of recurrent ventricular arrhythmias at the onset of acute myocarditis, suspected or proven, could be associated with a pre-existing arrhythmogenic substrate, therefore these patients should be submitted to electrophysiological study in order to rule out the presence of arrhythmogenic focuses that can be treated with transcatheter ablation.

  19. Radiofrequency thermal ablation of malignant hepatic tumors: post-ablation syndrome

    International Nuclear Information System (INIS)

    Choi, Jung Bin; Rhim, Hyunchul; Kim, Yongsoo; Koh, Byung Hee; Cho, On Koo; Seo, Heung Suk; Lee, Seung Ro

    2000-01-01

    To evaluate post-ablation syndrome after radiofrequency thermal ablation of malignant hepatic tumors. Forty-two patients with primary (n=3D29) or secondary (n=3D13) hepatic tumors underwent radiofrequency thermal ablation. A total of 65 nodules ranging in size from 1.1 to 5.0 (mean, 3.1) cm were treated percutaneously using a 50W RF generator with 15G expandable needle electrodes. We retrospectively evaluated the spectrum of post-ablation syndrome including pain, fever (≥3D 38 deg C), nausea, vomiting, right shoulder pain, and chest discomfort according to frequency, intensity and duration, and the findings were correlated with tumor location and number of ablations. We also evaluated changes in pre-/post-ablation serum aminotransferase (ALT/AST) and prothrombin time, and correlated these findings with the number of ablations. Post-ablation syndrome was noted in 29 of 42 patients (69.0%), and most symptoms improved with conservative treatment. The most important of these were abdominal plan (n=3D20, 47.6%), fever (n=3D8, 19.0%), and nausea (n=3D7, 16.7%), and four of 42 (9.5%) patients complained of severe pain. The abdominal pain lasted from 3 hours to 5.5 days (mean; 20.4 hours), the fever from 6 hours to 5 days (mean; 63.0 hours). And the nausea from 1 hours to 4 days (mean; 21.0 hours). Other symptoms were right shoulder pain (n=3D6, 14.3%), chest discomfort (n=3D3, 7.1%), and headache (n=3D3, 7.1%). Seventeen of 20 patients (85%) with abdominal pain had subcapsular tumor of the liver. There was significant correlation between pain, location of the tumor, and a number of ablations. After ablation, ALT/AST was elevated more than two-fold in 52.6%/73.7% of patients, respectively but there was no significant correlation with the number of ablation. Post-ablation syndrome is a frequent and tolerable post-procedural process after radiofrequency thermal ablation. The spectrum of this syndrome provides a useful guideline for the post-ablation management. (author)

  20. Causal Scale of Rotors in a Cardiac System

    Science.gov (United States)

    Ashikaga, Hiroshi; Prieto-Castrillo, Francisco; Kawakatsu, Mari; Dehghani, Nima

    2018-04-01

    Rotors of spiral waves are thought to be one of the potential mechanisms that maintain atrial fibrillation (AF). However, disappointing clinical outcomes of rotor mapping and ablation to eliminate AF raise a serious doubt on rotors as a macro-scale mechanism that causes the micro-scale behavior of individual cardiomyocytes to maintain spiral waves. In this study, we aimed to elucidate the causal relationship between rotors and spiral waves in a numerical model of cardiac excitation. To accomplish the aim, we described the system in a series of spatiotemporal scales by generating a renormalization group, and evaluated the causal architecture of the system by quantifying causal emergence. Causal emergence is an information-theoretic metric that quantifies emergence or reduction between micro- and macro-scale behaviors of a system by evaluating effective information at each scale. We found that the cardiac system with rotors has a spatiotemporal scale at which effective information peaks. A positive correlation between the number of rotors and causal emergence was observed only up to the scale of peak causation. We conclude that rotors are not the universal mechanism to maintain spiral waves at all spatiotemporal scales. This finding may account for the conflicting benefit of rotor ablation in clinical studies.

  1. SU-E-P-10: Imaging in the Cardiac Catheterization Lab - Technologies and Clinical Applications

    International Nuclear Information System (INIS)

    Fetterly, K

    2014-01-01

    Purpose: Diagnosis and treatment of cardiovascular disease in the cardiac catheterization laboratory is often aided by a multitude of imaging technologies. The purpose of this work is to highlight the contributions to patient care offered by the various imaging systems used during cardiovascular interventional procedures. Methods: Imaging technologies used in the cardiac catheterization lab were characterized by their fundamental technology and by the clinical applications for which they are used. Whether the modality is external to the patient, intravascular, or intracavity was specified. Specific clinical procedures for which multiple modalities are routinely used will be highlighted. Results: X-ray imaging modalities include fluoroscopy/angiography and angiography CT. Ultrasound imaging is performed with external, trans-esophageal echocardiography (TEE), and intravascular (IVUS) transducers. Intravascular infrared optical coherence tomography (IVOCT) is used to assess vessel endothelium. Relatively large (>0.5 mm) anatomical structures are imaged with x-ray and ultrasound. IVUS and IVOCT provide high resolution images of vessel walls. Cardiac CT and MRI images are used to plan complex cardiovascular interventions. Advanced applications are used to spatially and temporally merge images from different technologies. Diagnosis and treatment of coronary artery disease frequently utilizes angiography and intra-vascular imaging, and treatment of complex structural heart conditions routinely includes use of multiple imaging modalities. Conclusion: There are several imaging modalities which are routinely used in the cardiac catheterization laboratory to diagnose and treat both coronary artery and structural heart disease. Multiple modalities are frequently used to enhance the quality and safety of procedures. The cardiac catheterization laboratory includes many opportunities for medical physicists to contribute substantially toward advancing patient care

  2. Does three-dimensional transesophageal echocardiography provide incremental value in percutaneous closure of ascending aortic pseudoaneurysm?

    Science.gov (United States)

    Elkaryoni, Ahmed; Hsiung, Ming C; Arisha, Mohammed J; Ahmad, Amier; Nanda, Navin C; Mohamed, Ahmed H; Attia, Doaa; Sachdeva, Ankush; Singh, Lovepreet; Yin, Wei-Hsian

    2017-07-01

    Ascending aortic pseudoaneurysms (AO PSAs), if left untreated, are complicated by a high rate of rupture resulting in significant morbidity and mortality. New transcatheter modalities have emerged as acceptable surgical alternatives for their management. We present a case of an ascending aortic PSA in which intraoperative two- and three-dimensional transesophageal echocardiography (2DTEE and 3DTEE) provided a comprehensive assessment of the PSA in pre- and postclosure settings. © 2017, Wiley Periodicals, Inc.

  3. The quest for durable lesions in catheter ablation of atrial fibrillation - technological advances in radiofrequency catheters and balloon devices.

    Science.gov (United States)

    Maurer, Tilman; Kuck, Karl-Heinz

    2017-08-01

    Atrial fibrillation is the most common cardiac arrhythmia and represents a growing clinical, social and economic challenge. Catheter ablation for symptomatic atrial fibrillation has evolved from an experimental procedure into a widespread therapy and offers a safe and effective treatment option. A prerequisite for durable PVI are transmural and contiguous circumferential lesions around the pulmonary veins. However, electrical reconnection of initially isolated pulmonary veins remains a primary concern and is a dominant factor for arrhythmia recurrence during long-term follow up. Areas covered: This article discusses the physiology of lesion formation using radiofrequency-, cryo- or laser- energy for pulmonary vein isolation and provides a detailed review of recent technological advancements in the field of radiofrequency catheters and balloon devices. Finally, future directions and upcoming developments for the interventional treatment of atrial fibrillation are discussed. Expert commentary: Durable conduction block across deployed myocardial lesions is mandatory not only for PVI but for any other cardiac ablation strategy as well. A major improvement urgently expected is the intraprocedural real-time distinction of durable lesions from interposed gaps with only transiently impaired electrical conduction. Furthermore, a simplification of ablation tools used for PVI is required to reduce the high technical complexity of the procedure.

  4. Long-term prognostic value of transesophageal atrial pacing stress echocardiography.

    Science.gov (United States)

    Płońska, Edyta; Kasprzak, Jarosław D; Kornacewicz-Jach, Zdzisława

    2005-07-01

    The aim of our study was to evaluate the long-term prognostic value of transesophageal atrial pacing stress echocardiography (TAPSE) for the prediction of cardiovascular events (myocardial infarction) and mortality at 10-year follow-up. TAPSE was applied as a diagnostic modality in 93 consecutive patients (mean age 45 +/- 8 years) who were diagnosed for the cause of chest pain. Long-term follow-up data were obtained from 87 (94%) patients with a mean duration of follow-up of 92 +/- 4 months. Stress echocardiography was performed using TAPSE with a mean pacing rate of 142 +/- 18/min. Predefined cardiac events occurred during the follow-up period in 45 (52%) patients, including 24 (28%) with hard end points: 10 (12%) with nonfatal myocardial infarction and 17 who died (events overlap). Positive result of TAPSE was found in 47 (54%) patients and among those with positive TAPSE result, 16 died (94% of total mortality) and 21 had a hard event (death or infarction-88% of total prevalence). Survival free from hard events was noted in 37 (92%) patients with negative TAPSE and only in 26 (55%) of those with positive TAPSE ( P = .001). Independent predictive factors for mortality were TAPSE positivity (relative risk with 95% confidence interval [RR/CI] = 39.6 [36.3-42.9], P = .0006) and diabetes (RR/CI = 10.2 [8.6-11.8], P = .0026). Independent predictive factors for myocardial infarction were diabetes (RR/CI = 8.1 [6.3-9.9], P = .0186) and significant coronary stenosis in angiography (RR/CI = 9.0 [6.8-11.2], P = .0479). Independent predictive factors for death or nonfatal myocardial infarction were TAPSE positivity (RR/CI = 12.3 [11.1-13.3], P = .0001) and diabetes (RR/CI = 7.0 [5.8-8.2], P = .0018). Positive TAPSE result carries long-term prognostic information regarding mortality and risk of myocardial infarction that can be used to identify patients requiring more aggressive treatment. Negative TAPSE allows highly accurate definition of low-risk population with

  5. Comparison of wet radiofrequency ablation with dry radiofrequency ablation and radiofrequency ablation using hypertonic saline preinjection: ex vivo bovine liver

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Joon Koo; Kim, Se Hyung; Lee, Jae Young; Park, Hee Sun; Hur, Hurn; Choi, Byung Ihn; Shin, Kyung Sook

    2004-01-01

    We wished to compare the in-vitro efficiency of wet radiofrequency (RF) ablation with the efficiency of dry RF ablation and RF ablation with preinjection of NaCl solutions using excised bovine liver. Radiofrequency was applied to excised bovine livers in a monopolar mode for 10 minutes using a 200 W generator and a perfused-cooled electrode with or without injection or slow infusion of NaCl solutions. After placing the perfused-cooled electrode in the explanted liver, 50 ablation zones were created with five different regimens: group A; standard dry RF ablation, group B; RF ablation with 11 mL of 5% NaCl solution preinjection, group C; RF ablation with infusion of 11 mL of 5% NaCl solution at a rate of 1 mL/min, group D; RFA with 6 mL of 36% NaCl solution preinjection, group E; RF ablation with infusion of 6 mL of 36% NaCl solution at a rate of 0.5 mL/min. In groups C and E, infusion of the NaCl solutions was started 1 min before RF ablation and then maintained during RF ablation (wet RF ablation). During RF ablation, we measured the tissue temperature at 15 mm from the electrode. The dimensions of the ablation zones and changes in impedance, current and liver temperature during RF ablation were then compared between the groups. With injection or infusion of NaCl solutions, the mean initial tissue impedance prior to RF ablation was significantly less in groups B, C, D, and E (43-75 Ω) than for group A (80 Ω) (ρ 3 in group A; 12.4 ± 3.8 cm 3 in group B; 80.9 ± 9.9 cm 3 in group C; 45.3 ± 11.3 cm 3 in group D and 81.6 ± 8.6 cm 3 in group E. The tissue temperature measured at 15 mm from the electrode was higher in groups C, D and E than other groups (ρ < 0.05): 53 ± 12 .deg. C in group A, 42 ± 2 .deg. C in group B, 93 ± 8 .deg. C in group C; 79 ± 12 .deg. C in group D and 83 ± 8 .deg.C in group E. Wet RF ablation with 5% or 36% NaCl solutions shows better efficiency in creating a large ablation zone than does dry RF ablation or RF ablation with

  6. The effect of integrated cardiac rehabilitation versus treatment as usual for atrial fibrillation patients treated with ablation

    DEFF Research Database (Denmark)

    Risom, Signe Stelling; Zwisler, Ann-Dorth Olsen; Rasmussen, Trine Bernholdt

    2013-01-01

    fibrillation treated with ablation. METHODS AND ANALYSIS DESIGN: The trial is a multicentre parallel arm design with 1:1 randomisation to the intervention and control group with blinded outcome assessment. 210 patients treated for atrial fibrillation with radiofrequency ablation will be included...... measure is exercise capacity measured by the VO(2) peak. The secondary outcome measure is self-rated mental health measured by the Short Form 36 questionnaire. Postintervention, qualitative interviews will be conducted in 10% of the intervention group. ETHICS AND DISSEMINATION: The protocol is approved...

  7. Evaluation of concordance among three cardiac output measurement techniques in adult patients during cardiovascular surgery postoperative care.

    Science.gov (United States)

    Muñoz, L; Velandia, A; Reyes, L E; Arevalo-Rodríguez, I; Mejía, C; Asprilla, D; Uribe, D V; Arevalo, J J

    2017-12-01

    The standard method for cardiac output measuring is thermodilution although it is an invasive technique. Transesophageal Echocardiography (TEE) offers a dynamic and functional alternative to thermodilution. Analyze concordance between two TEE methods and thermodilution for cardiac output assessment. Observational concordance study in cardiovascular surgery patients that required pulmonary artery catheter. TEE cardiac output measurement at both mitral annulus (MA) and left ventricle outflow tract (LVOT) were performed. Results were compared with thermodilution. Correlation was evaluated by Lin's concordance correlation coefficient and Bland-Altman analysis. Statistical analysis was undertaken in STATA 13.0. Twenty-five patients were enrolled. Fifty two percent of patients were male, median age and ejection fraction was 63 years and 35% respectively. Median thermodilution, LVOT and MA -measured cardiac output was 3.25 L/min, 3.46 L/min and 8.4 L/min respectively. Different values between thermodilution and MA measurements were found (Lin concordance=0.071; Confidence Interval 95%=-0.009 to 0.151; Spearman's correlation=0.22) as values between thermodilution and LVOT (Lin concordance=0.232; Confidence Interval 95%=-0.12 a 0.537; Spearman's correlation 0.28). Bland-Altman analysis showed greater difference between MA measurements and thermodilution (DM=-0.408; Bland-Altman Limits=-0.809 to -0.007), than the other echocardiographic findings (DM=0.007; Bland-Altman Limits=-0.441 to 0.428). Results from cardiac output measurement by doppler and 2D-TEE on both MA and LVOT do not correlate with those obtained by thermodilution. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  8. Intraoperative Transesophageal Echocardiography and Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Silverton, Natalie A; Patel, Ravi; Zimmerman, Josh; Ma, Jianing; Stoddard, Greg; Selzman, Craig; Morrissey, Candice K

    2018-02-15

    To determine whether intraoperative measures of right ventricular (RV) function using transesophageal echocardiography are associated with subsequent RV failure after left ventricular assist device (LVAD) implantation. Retrospective, nonrandomized, observational study. Single tertiary-level, university-affiliated hospital. The study comprised 100 patients with systolic heart failure undergoing elective LVAD implantation. Transesophageal echocardiographic images before and after cardiopulmonary bypass were analyzed to quantify RV function using tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity (S'), fractional area change (FAC), RV global longitudinal strain, and RV free wall strain. A chart review was performed to determine which patients subsequently developed RV failure (right ventricular assist device placement or prolonged inotrope requirement ≥14 days). Nineteen patients (19%) subsequently developed RV failure. Postbypass FAC was the only measure of RV function that distinguished between the RV failure and non-RV failure groups (21.2% v 26.5%; p = 0.04). The sensitivity, specificity, and area under the curve of an abnormal RV FAC (failure after LVAD implantation were 84%, 20%, and 0.52, respectively. No other intraoperative measure of RV function was associated with subsequent RV failure. RV failure increased ventilator time, intensive care unit and hospital length of stay, and mortality. Intraoperative measures of RV function such as tricuspid annular plane systolic excursion, tricuspid annular systolic velocity, and RV strain were not associated with RV failure after LVAD implantation. Decreased postbypass FAC was significantly associated with RV failure but showed poor discrimination. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Prediction of radiofrequency ablation lesion formation using a novel temperature sensing technology incorporated in a force sensing catheter.

    Science.gov (United States)

    Rozen, Guy; Ptaszek, Leon; Zilberman, Israel; Cordaro, Kevin; Heist, E Kevin; Beeckler, Christopher; Altmann, Andres; Ying, Zhang; Liu, Zhenjiang; Ruskin, Jeremy N; Govari, Assaf; Mansour, Moussa

    2017-02-01

    Real-time radiofrequency (RF) ablation lesion assessment is a major unmet need in cardiac electrophysiology. The purpose of this study was to assess whether improved temperature measurement using a novel thermocoupling (TC) technology combined with information derived from impedance change, contact force (CF) sensing, and catheter orientation allows accurate real-time prediction of ablation lesion formation. RF ablation lesions were delivered in the ventricles of 15 swine using a novel externally irrigated-tip catheter containing 6 miniature TC sensors in addition to force sensing technology. Ablation duration, power, irrigation rate, impedance drop, CF, and temperature from each sensor were recorded. The catheter "orientation factor" was calculated using measurements from the different TC sensors. Information derived from all the sources was included in a mathematical model developed to predict lesion depth and validated against histologic measurements. A total of 143 ablation lesions were delivered to the left ventricle (n = 74) and right ventricle (n = 69). Mean CF applied during the ablations was 14.34 ± 3.55g, and mean impedance drop achieved during the ablations was 17.5 ± 6.41 Ω. Mean difference between predicted and measured ablation lesion depth was 0.72 ± 0.56 mm. In the majority of lesions (91.6%), the difference between estimated and measured depth was ≤1.5 mm. Accurate real-time prediction of RF lesion depth is feasible using a novel ablation catheter-based system in conjunction with a mathematical prediction model, combining elaborate temperature measurements with information derived from catheter orientation, CF sensing, impedance change, and additional ablation parameters. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. An experimental study of simultaneous ablation with dual probes in radiofrequency thermal ablation

    International Nuclear Information System (INIS)

    Jang, Il Soo; Rhim, Hyun Chul; Koh, Byung Hee; Cho, On Koo; Seo, Heung Suk; Kim, Yong Soo; Kim, Young Sun; Heo, Jeong Nam

    2003-01-01

    To determine the differences between sequential ablation with a single probe and simultaneous ablation with dual probes. Using two 14-gauge expandable probes (nine internal prongs with 4-cm deployment), radiofrequency was applied sequentially (n=8) or simultaneously (n=8) to ten ex-vivo cow livers. Before starting ablation, two RF probes with an inter-probe space of 2 cm (n=8) or 3 cm (n=8) were inserted. In the sequential group, switching the connecting cable to an RF generator permitted ablation with the second probe just after ablation with the first probe had finished. In the simultaneous group, single ablation was performed only after connecting the shafts of both RF probes using a connection device. Each ablation lasted 7 minutes at a target temperature of 105-110 .deg. C. The size and shape of the ablated area, and total ablation time were then compared between the two groups. With 2-cm spacing, the group, mean length and overlapping width of ablated lesions were, respectively, 5.20 and 5.05 cm in the sequential group (n=4), and 5.81 and 5.65 cm in the simultaneous group (n=4). With 3-cm spacing, the corresponding figures were 4.99 and 5.60 cm in the sequential group (n=4), and 6.04 and 6.78 cm in the simultaneous group (n=4). With 2-cm spacing, the mean depth of the proximal waist was 0.58 cm in the sequential (group and 0.28 cm in the simultaneous group, while with 3-cm spacing, the corresponding figures were 1.65 and 1.48 cm. In neither group was there a distal waist. Mean total ablation time was 23.4 minutes in the sequential group and 14 minutes in the simultaneous group. In terms of ablation size and ablation time, simultaneous radiofrequency ablation with dual probes is superior to sequential ablation with a single probe. A simultaneous approach will enable an operator to overcome difficulty in probe repositioning during overlapping ablation, resulting in complete ablation with a successful safety margin

  11. Effect of rehabilitation on sleep quality after ablation for atrial fibrillation

    DEFF Research Database (Denmark)

    Risom, Signe Stelling; Fevejle Cromhout, Pernille; Overgaard, Dorthe

    2018-01-01

    to investigate (1) differences in sleep quality between cardiac rehabilitation and usual care groups and (2) whether other factors could affect sleep quality. Methods: From the randomized CopenHeartRFA trial, 210 patients treated for AF with ablation were included. A rehabilitation program consisting of physical...... exercise and psychoeducational consultations was tested. Sleep quality was measured with the Pittsburg Sleep Quality Index (PSQI) questionnaire before intervention and at the end of intervention. Anxiety, depression, and European Heart Rhythm Association scores were assessed. Results: No difference between...... groups in sleep quality was found (PSQI global mean [SD] score, 6.60 [3.61] points for the cardiac rehabilitation group [n = 83] and 6.08 [3.60] points for the usual care group [n = 90]; P = .34), although improvements in sleep quality were noted in both groups. Sleep latency, duration...

  12. Cardiac-specific catalase overexpression rescues anthrax lethal toxin-induced cardiac contractile dysfunction: role of oxidative stress and autophagy.

    Science.gov (United States)

    Kandadi, Machender R; Yu, Xuejun; Frankel, Arthur E; Ren, Jun

    2012-11-07

    Lethal and edema toxins secreted by Bacillus anthracis during anthrax infection were found to incite serious cardiovascular complications. However, the underlying mechanisms in anthrax lethal toxin-induced cardiac anomalies remain unknown. This study was designed to evaluate the impact of antioxidant enzyme catalase in anthrax lethal toxin-induced cardiomyocyte contractile dysfunction. Wild type (WT) and cardiac-specific catalase overexpression mice were challenged with lethal toxin (2 μg/g, intraperotineally (i.p.)). Cardiomyocyte contractile and intracellular Ca(2+) properties were assessed 18 h later using an IonOptix edge-detection system. Proteasome function was assessed using chymotrypsin-like and caspase-like activities. GFP-LC3 puncta and Western blot analysis were used to evaluate autophagy and protein ubiquitination. Lethal toxin exposure suppressed cardiomyocyte contractile function (suppressed peak shortening, maximal velocity of shortening/re-lengthening, prolonged duration of shortening/re-lengthening, and impaired intracellular Ca(2+) handling), the effects of which were alleviated by catalase. In addition, lethal toxin triggered autophagy, mitochondrial and ubiquitin-proteasome defects, the effects of which were mitigated by catalase. Pretreatment of cardiomyocytes from catalase mice with the autophagy inducer rapamycin significantly attenuated or ablated catalase-offered protection against lethal toxin-induced cardiomyocyte dysfunction. On the other hand, the autophagy inhibitor 3-MA ablated or significantly attenuated lethal toxin-induced cardiomyocyte contractile anomalies. Our results suggest that catalase is protective against anthrax lethal toxin-induced cardiomyocyte contractile and intracellular Ca(2+) anomalies, possibly through regulation of autophagy and mitochondrial function.

  13. Ablation mass features in multi-pulses femtosecond laser ablate molybdenum target

    Science.gov (United States)

    Zhao, Dongye; Gierse, Niels; Wegner, Julian; Pretzler, Georg; Oelmann, Jannis; Brezinsek, Sebastijan; Liang, Yunfeng; Neubauer, Olaf; Rasinski, Marcin; Linsmeier, Christian; Ding, Hongbin

    2018-03-01

    In this study, the ablation mass features related to reflectivity of bulk Molybdenum (Mo) were investigated by a Ti: Sa 6 fs laser pulse at central wavelength 790 nm. The ablated mass removal was determined using Confocal Microscopy (CM) technique. The surface reflectivity was calibrated and measured by a Lambda 950 spectrophotometer as well as a CCD camera during laser ablation. The ablation mass loss per pulse increase with the increasing of laser shots, meanwhile the surface reflectivity decrease. The multi-pulses (100 shots) ablation threshold of Mo was determined to be 0.15 J/cm2. The incubation coefficient was estimated as 0.835. The reflectivity change of the Mo target surface following multi-pulses laser ablation were studied as a function of laser ablation shots at various laser fluences from 1.07 J/cm2 to 36.23 J/cm2. The results of measured reflectivity indicate that surface reflectivity of Mo target has a significant decline in the first 3-laser pulses at the various fluences. These results are important for developing a quantitative analysis model for laser induced ablation and laser induced breakdown spectroscopy for the first wall diagnosis of EAST tokamak.

  14. The transesophageal echocardiography simulator based on computed tomography images.

    Science.gov (United States)

    Piórkowski, Adam; Kempny, Aleksander

    2013-02-01

    Simulators are a new tool in education in many fields, including medicine, where they greatly improve familiarity with medical procedures, reduce costs, and, importantly, cause no harm to patients. This is so in the case of transesophageal echocardiography (TEE), in which the use of a simulator facilitates spatial orientation and helps in case studies. The aim of the project described in this paper is to simulate an examination by TEE. This research makes use of available computed tomography data to simulate the corresponding echocardiographic view. This paper describes the essential characteristics that distinguish these two modalities and the key principles of the wave phenomena that should be considered in the simulation process, taking into account the conditions specific to the echocardiography. The construction of the CT2TEE (Web-based TEE simulator) is also presented. The considerations include ray-tracing and ray-casting techniques in the context of ultrasound beam and artifact simulation. An important aspect of the interaction with the user is raised.

  15. Ten-year outcomes of monomorphic ventricular tachycardia catheter ablation in repaired tetralogy of Fallot.

    Science.gov (United States)

    Laredo, Mikaël; Frank, Robert; Waintraub, Xavier; Gandjbakhch, Estelle; Iserin, Laurence; Hascoët, Sebastien; Himbert, Caroline; Gallais, Yves; Hidden-Lucet, Françoise; Duthoit, Guillaume

    2017-05-01

    Monomorphic ventricular tachycardia (MVT) is common in adults with repaired tetralogy of Fallot (TOF), and is associated with sudden cardiac death. Management of MVT is not defined, and results of catheter ablation (CA) are limited. To evaluate long-term outcomes of MVT CA in repaired TOF. Thirty-four patients (mean age 32±10.3 years; 59% male) with repaired TOF underwent CA for symptomatic MVT between 1990 and 2012 in our centre; direct-current ablation (DCA) was used in 6%, radiofrequency followed by DCA in 29% and radiofrequency alone in 65%. Right ventricular (RV) dysfunction was present in 35% and left ventricular (LV) dysfunction in 21%. Mean numbers of clinical and induced MVTs were 1 and 2, respectively. Mean VT rate was 225±95bpm. Ablation targeted a single site (range 1-2), which was RV outflow tract in 85%. Primary success, defined as ventricular tachycardia (VT) termination during CA and final non-inducibility, was obtained in 82%. Seven patients (21%) required redo ablation in the first 3 months (before 2004; DCA). No death related to CA occurred. Mean follow-up time was 9.5±5.2 years. Antiarrhythmic therapy was discontinued in 71%. There were two cases of sudden cardiac death and four VT recurrences. Freedom from death and arrhythmia recurrence was 94% at 5 years, 81% at 10 years and 70% at 20 years. Global survival was 91% at 20 years. Baseline LV ejection fraction<60% was significantly associated with ventricular arrhythmia recurrence (hazard ratio 16.4, 95% confidence interval 1.8-147; P=0.01). CA can safely address macroreentrant MVT in repaired TOF patients with an acceptable long-term rate of recurrence in this high-risk population. Anatomical classification of isthmuses with electroanatomical mapping provides reproducible endpoints for CA. Attention should be given to LV systolic function in risk assessment and selection of candidates for implantable cardioverter-defibrillator. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Effect of percutaneous renal sympathetic nerve radiofrequency ablation in patients with severe heart failure.

    Science.gov (United States)

    Dai, Qiming; Lu, Jing; Wang, Benwen; Ma, Genshan

    2015-01-01

    This study aimed to investigate the clinical feasibility and effects of percutaneous renal sympathetic nerve radiofrequency ablation in patients with heart failure. A total of 20 patients with heart failure were enrolled, aged from 47 to 75 years (63±10 years). They were divided into the standard therapy (n = 10), and renal nerve radiofrequency ablation groups (n = 10). There were 15 males and 5 female patients, including 8 ischemic cardiomyopathy, 8 dilated cardiomyopathy, and 8 hypertensive cardiopathy. All of the patients met the criteria of New York Heart Association classes III-IV cardiac function. Patients with diabetes and renal failure were excluded. Percutaneous renal sympathetic nerve radiofrequency ablation was performed on the renal artery wall under X-ray guidance. Serum electrolytes, neurohormones, and 24 h urine volume were recorded 24 h before and after the operation. Echocardiograms were performed to obtain left ventricular ejection fraction at baseline and 6 months. Heart rate, blood pressure, symptoms of dyspnea and edema were also monitored. After renal nerve ablation, 24 h urine volume was increased, while neurohormone levels were decreased compared with those of pre-operation and standard therapy. No obvious change in heart rate or blood pressure was recorded. Symptoms of heart failure were improved in patients after the operation. No complications were recorded in the study. Percutaneous renal sympathetic nerve radiofrequency ablation may be a feasible, safe, and effective treatment for the patients with severe congestive heart failure.

  17. Real-time MRI guidance of cardiac interventions.

    Science.gov (United States)

    Campbell-Washburn, Adrienne E; Tavallaei, Mohammad A; Pop, Mihaela; Grant, Elena K; Chubb, Henry; Rhode, Kawal; Wright, Graham A

    2017-10-01

    Cardiac magnetic resonance imaging (MRI) is appealing to guide complex cardiac procedures because it is ionizing radiation-free and offers flexible soft-tissue contrast. Interventional cardiac MR promises to improve existing procedures and enable new ones for complex arrhythmias, as well as congenital and structural heart disease. Guiding invasive procedures demands faster image acquisition, reconstruction and analysis, as well as intuitive intraprocedural display of imaging data. Standard cardiac MR techniques such as 3D anatomical imaging, cardiac function and flow, parameter mapping, and late-gadolinium enhancement can be used to gather valuable clinical data at various procedural stages. Rapid intraprocedural image analysis can extract and highlight critical information about interventional targets and outcomes. In some cases, real-time interactive imaging is used to provide a continuous stream of images displayed to interventionalists for dynamic device navigation. Alternatively, devices are navigated relative to a roadmap of major cardiac structures generated through fast segmentation and registration. Interventional devices can be visualized and tracked throughout a procedure with specialized imaging methods. In a clinical setting, advanced imaging must be integrated with other clinical tools and patient data. In order to perform these complex procedures, interventional cardiac MR relies on customized equipment, such as interactive imaging environments, in-room image display, audio communication, hemodynamic monitoring and recording systems, and electroanatomical mapping and ablation systems. Operating in this sophisticated environment requires coordination and planning. This review provides an overview of the imaging technology used in MRI-guided cardiac interventions. Specifically, this review outlines clinical targets, standard image acquisition and analysis tools, and the integration of these tools into clinical workflow. 1 Technical Efficacy: Stage 5 J

  18. Surgical ablation of ventricular tachycardia secondary to congenital ventricular septal aneurysm.

    Science.gov (United States)

    Graffigna, A; Minzioni, G; Ressia, L; Vigano, M

    1994-04-01

    Three patients underwent surgical ablation for ventricular tachycardia resulting from an aneurysm of the membranous portion of the ventricular septum. Two patients had a definite history of cardiac murmur during infancy, and one of them was found at the time of operation to have a left-to-right shunt through the apex of the aneurysm. The earliest ventricular activation sites were located around the neck of the aneurysm and were ablated in 1 patient by encircling the endocardial ventriculotomy and by cryoablation in the remaining 2. After focus resection had been completed, aneurysm resection and ventricular septal reconstruction were performed. All patients were alive and free of ventricular tachycardia and did not need medication as of 61, 66, and 88 months postoperatively. Spontaneous closure of a ventricular septal defect may lead to the formation of an aneurysm in the ventricular septum that may sustain ventricular tachycardias. Such arrhythmias can be effectively treated using electrically guided surgical techniques.

  19. Safety of atrial fibrillation ablation with novel multi-electrode array catheters on uninterrupted anticoagulation-a single-center experience.

    LENUS (Irish Health Repository)

    Hayes, Christopher Ruslan

    2012-02-01

    INTRODUCTION: A recent single-center report indicated that the performance of atrial fibrillation ablation in patients on uninterrupted warfarin using a conventional deflectable tip electrode ablation catheter may be as safe as periprocedural discontinuation of warfarin and bridging with heparin. Novel multi-electrode array catheters for atrial fibrillation ablation are currently undergoing clinical evaluation. While offering the possibility of more rapid atrial fibrillation ablation, they are stiffer and necessitate the deployment of larger deflectable transseptal sheaths, and it remains to be determined if they increase the risk of cardiac perforation and vascular injury. Such potential risks would have implications for a strategy of uninterrupted periprocedural anticoagulation. METHOD AND RESULTS: We audited the safety outcomes of our atrial fibrillation ablation procedures using multi-electrode array ablation catheters in patients on uninterrupted warfarin (CHADS2 score>or=2) and in patients not on warfarin (uninterrupted aspirin). Two bleeding complications occurred in 49 patients on uninterrupted warfarin, both of which were managed successfully without longterm sequelae, and no bleeding complication occurred in 32 patients not on warfarin (uninterrupted aspirin). There were no thromboembolic events or other complication with either anticoagulant regimen. CONCLUSION: Despite the larger diameter and increased stiffness of multi-electrode array catheters and their deflectable transseptal sheaths, their use for catheter ablation in patients with atrial fibrillation on uninterrupted warfarin in this single-center experience does not appear to be unsafe, and thus, an adequately powered multicenter prospective randomized controlled trial should be considered.

  20. Radiofrequency Ablation of Lung Tumors

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Radiofrequency Ablation (RFA) / Microwave Ablation (MWA) of Lung Tumors ... and Microwave Ablation of Lung Tumors? What are Radiofrequency and Microwave Ablation of Lung Tumors? Radiofrequency ablation, ...

  1. Electrophysiology testing and catheter ablation are helpful when evaluating asymptomatic patients with Wolff-Parkinson-White pattern: the pro perspective.

    Science.gov (United States)

    Pappone, Carlo; Santinelli, Vincenzo

    2015-09-01

    Important advances in the natural history and diagnosis of, and therapy for, asymptomatic Wolff-Parkinson-White (WPW) syndrome have been made in the last decade by our group. These data have necessitated revisiting current practice guidelines to decide on the optimal management of the asymptomatic WPW population. There has also been an emphasis on identifying initially asymptomatic individuals who are at risk by nationwide screening programs using the electrocardiogram for prophylactic catheter ablation to prevent the lifetime risk of sudden cardiac death, particularly in young asymptomatic people, because only a subgroup of them is at high risk, requiring early catheter ablation. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Segmentation of multiple heart cavities in 3-D transesophageal ultrasound images.

    Science.gov (United States)

    Haak, Alexander; Vegas-Sánchez-Ferrero, Gonzalo; Mulder, Harriët W; Ren, Ben; Kirişli, Hortense A; Metz, Coert; van Burken, Gerard; van Stralen, Marijn; Pluim, Josien P W; van der Steen, Antonius F W; van Walsum, Theo; Bosch, Johannes G

    2015-06-01

    Three-dimensional transesophageal echocardiography (TEE) is an excellent modality for real-time visualization of the heart and monitoring of interventions. To improve the usability of 3-D TEE for intervention monitoring and catheter guidance, automated segmentation is desired. However, 3-D TEE segmentation is still a challenging task due to the complex anatomy with multiple cavities, the limited TEE field of view, and typical ultrasound artifacts. We propose to segment all cavities within the TEE view with a multi-cavity active shape model (ASM) in conjunction with a tissue/blood classification based on a gamma mixture model (GMM). 3-D TEE image data of twenty patients were acquired with a Philips X7-2t matrix TEE probe. Tissue probability maps were estimated by a two-class (blood/tissue) GMM. A statistical shape model containing the left ventricle, right ventricle, left atrium, right atrium, and aorta was derived from computed tomography angiography (CTA) segmentations by principal component analysis. ASMs of the whole heart and individual cavities were generated and consecutively fitted to tissue probability maps. First, an average whole-heart model was aligned with the 3-D TEE based on three manually indicated anatomical landmarks. Second, pose and shape of the whole-heart ASM were fitted by a weighted update scheme excluding parts outside of the image sector. Third, pose and shape of ASM for individual heart cavities were initialized by the previous whole heart ASM and updated in a regularized manner to fit the tissue probability maps. The ASM segmentations were validated against manual outlines by two observers and CTA derived segmentations. Dice coefficients and point-to-surface distances were used to determine segmentation accuracy. ASM segmentations were successful in 19 of 20 cases. The median Dice coefficient for all successful segmentations versus the average observer ranged from 90% to 71% compared with an inter-observer range of 95% to 84%. The

  3. Transvenous cold mapping and cryoablation of the AV node in dogs: observations of chronic lesions and comparison to those obtained using radiofrequency ablation

    NARCIS (Netherlands)

    Rodriguez, L. M.; Leunissen, J.; Hoekstra, A.; Korteling, B. J.; Smeets, J. L.; Timmermans, C.; Vos, M.; Daemen, M.; Wellens, H. J.

    1998-01-01

    Radiofrequency (RF) is the most commonly used energy source for the treatment of cardiac arrhythmias. Surgical experience has shown that cryoablation also is effective for ablating arrhythmias. The aims of this study were to (1) investigate the feasibility of inducing permanent complete AV block

  4. Effect of ablatant composition on the ablation of a fuelling pellet

    International Nuclear Information System (INIS)

    Chang, C.T.; Thomsen, K.; Piret, S.

    1988-01-01

    The single species neutral-shielding model for the ablation of a hydrogenic pellet is extended by considering the ablatant as a mixture of four species: molecular and atomic hydrogen, protons and electrons. Compared with the results of the frozen flow, (i.e. the single species molecular hydrogen gas model), results of the analysis showed that the presence of dissociation and ionization effects caused a marked difference of the ablatant state. The attenuations of the incoming electron energy and energy flux, however, are very much similar irrespective of whether the ablated flow is in a frozen or an equilibrium state. The scaling law of the pellet ablation rate with respect to the plasma state of Te, ne and the pellet radius remains the same; the ablation rate is reduced by approximately 15%. To examine the possible existence of a spherical shell around the pellet where most of the incoming electron energy is absorbed, acodmparison is made between the local electron collisional mean free path and the electron Larmor radius. A critical field at the ionization radius is evaluated. An effective spherical energyabsorbing region exists when the local field strength is below the critical value. For a plasma state of low Te and ne, (where the ablatant is hardly ionized), and for one near the thermonuclear condition (where a highly dense ablatant exists near the pellet), the effective energy absorption region is nearly spherical. 20 refs. (author)

  5. Robotics in Cardiac Surgery: Past, Present, and Future

    Directory of Open Access Journals (Sweden)

    Bryan Bush

    2013-07-01

    Full Text Available Robotic cardiac operations evolved from minimally invasive operations and offer similar theoretical benefits, including less pain, shorter length of stay, improved cosmesis, and quicker return to preoperative level of functional activity. The additional benefits offered by robotic surgical systems include improved dexterity and degrees of freedom, tremor-free movements, ambidexterity, and the avoidance of the fulcrum effect that is intrinsic when using long-shaft endoscopic instruments. Also, optics and operative visualization are vastly improved compared with direct vision and traditional videoscopes. Robotic systems have been utilized successfully to perform complex mitral valve repairs, coronary revascularization, atrial fibrillation ablation, intracardiac tumor resections, atrial septal defect closures, and left ventricular lead implantation. The history and evolution of these procedures, as well as the present status and future directions of robotic cardiac surgery, are presented in this review.

  6. Left ventricular outflow tract arrhythmias with divergent QRS morphology: mapping of different exits and ablation strategy.

    Science.gov (United States)

    Reithmann, Christopher; Fiek, Michael

    2018-01-01

    Ventricular arrhythmias (VAs) from the left ventricular outflow tract (LVOT) can have multiple exits exhibiting divergent ECG features. In a series of 131 patients with VAs with LVOT origin, 10 patients presented with divergent QRS morphologies. Multisite endo- and epicardial mapping of different exit sites was performed. The earliest ventricular activity of 23 LVOT VAs in 10 patients was detected in the endocardium of the LV in 7 patients, the aortic sinuses of Valsalva (SoV) in 3 patients, the distal coronary sinus in 6 patients, the anterior interventricular vein in 3 patients, and the posterior right ventricular outflow tract (RVOT) in 4 patients. Simultaneous elimination of two divergent QRS morphologies of LVOT VAs by ablation from a single site was achieved in 5 patients (aorto-mitral continuity in 3 patients, SoV and RVOT in each 1 patient) using a mean maximum ablation energy of 46 ± 5 W. Sequential ablation from two or three different sites, including trans-pericardial and distal coronary sinus ablation in each 2 patients, led to elimination of the divergent VA QRS morphologies in the other 5 patients. During the follow-up of 28 ± 29 months, 4 of the 10 patients had recurrence of at least one LVOT VA. A 43-year-old patient with muscular dystrophy Curschmann-Steinert had recurrence of sustained LVOT VTs and died of sudden cardiac death. Multisite mapping of different exit sites of LVOT VAs can guide ablation of intramural foci but the recurrence rate after initially successful ablation was high.

  7. Cardiac-specific catalase overexpression rescues anthrax lethal toxin-induced cardiac contractile dysfunction: role of oxidative stress and autophagy

    Directory of Open Access Journals (Sweden)

    Kandadi Machender R

    2012-11-01

    Full Text Available Abstract Background Lethal and edema toxins secreted by Bacillus anthracis during anthrax infection were found to incite serious cardiovascular complications. However, the underlying mechanisms in anthrax lethal toxin-induced cardiac anomalies remain unknown. This study was designed to evaluate the impact of antioxidant enzyme catalase in anthrax lethal toxin-induced cardiomyocyte contractile dysfunction. Methods Wild type (WT and cardiac-specific catalase overexpression mice were challenged with lethal toxin (2 μg/g, intraperotineally (i.p.. Cardiomyocyte contractile and intracellular Ca2+ properties were assessed 18 h later using an IonOptix edge-detection system. Proteasome function was assessed using chymotrypsin-like and caspase-like activities. GFP-LC3 puncta and Western blot analysis were used to evaluate autophagy and protein ubiquitination. Results Lethal toxin exposure suppressed cardiomyocyte contractile function (suppressed peak shortening, maximal velocity of shortening/re-lengthening, prolonged duration of shortening/re-lengthening, and impaired intracellular Ca2+ handling, the effects of which were alleviated by catalase. In addition, lethal toxin triggered autophagy, mitochondrial and ubiquitin-proteasome defects, the effects of which were mitigated by catalase. Pretreatment of cardiomyocytes from catalase mice with the autophagy inducer rapamycin significantly attenuated or ablated catalase-offered protection against lethal toxin-induced cardiomyocyte dysfunction. On the other hand, the autophagy inhibitor 3-MA ablated or significantly attenuated lethal toxin-induced cardiomyocyte contractile anomalies. Conclusions Our results suggest that catalase is protective against anthrax lethal toxin-induced cardiomyocyte contractile and intracellular Ca2+ anomalies, possibly through regulation of autophagy and mitochondrial function.

  8. Real-time optical monitoring of permanent lesion progression in radiofrequency ablated cardiac tissue (Conference Presentation)

    Science.gov (United States)

    Singh-Moon, Rajinder P.; Hendon, Christine P.

    2016-02-01

    Despite considerable advances in guidance of radiofrequency ablation (RFA) therapies for atrial fibrillation, success rates have been hampered by an inability to intraoperatively characterize the extent of permanent injury. Insufficient lesions can elusively create transient conduction blockages that eventually reconduct. Prior studies suggest significantly greater met-myoglobin (Mmb) concentrations in the lesion core than those in the healthy myocardium and may serve as a marker for irreversible tissue damage. In this work, we present real-time monitoring of permanent injury through spectroscopic assessment of Mmb concentrations at the catheter tip. Atrial wedges (n=6) were excised from four fresh swine hearts and submerged under pulsatile flow of warm (37oC) phosphate buffered saline. A commercial RFA catheter inserted into a fiber optic sheath allowed for simultaneous measurement of tissue diffuse reflectance (DR) spectra (500-650nm) during application of RF energy. Optical measurements were continuously acquired before, during, and post-ablation, in addition to healthy neighboring tissue. Met-myoglobin, oxy-myoglobin, and deoxy-myoglobin concentrations were extracted from each spectrum using an inverse Monte Carlo method. Tissue injury was validated with Masson's trichrome and hematoxylin and eosin staining. Time courses revealed a rapid increase in tissue Mmb concentrations at the onset of RFA treatment and a gradual plateauing thereafter. Extracted Mmb concentrations were significantly greater post-ablation (p<0.0001) as compared to healthy tissue and correlated well with histological assessment of severe thermal tissue destruction. On going studies are aimed at integrating these findings with prior work on near infrared spectroscopic lesion depth assessment. These results support the use of spectroscopy-facilitated guidance of RFA therapies for real-time permanent injury estimation.

  9. Disruption of Ah Receptor Signaling during Mouse Development Leads to Abnormal Cardiac Structure and Function in the Adult.

    Directory of Open Access Journals (Sweden)

    Vinicius S Carreira

    Full Text Available The Developmental Origins of Health and Disease (DOHaD Theory proposes that the environment encountered during fetal life and infancy permanently shapes tissue physiology and homeostasis such that damage resulting from maternal stress, poor nutrition or exposure to environmental agents may be at the heart of adult onset disease. Interference with endogenous developmental functions of the aryl hydrocarbon receptor (AHR, either by gene ablation or by exposure in utero to 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD, a potent AHR ligand, causes structural, molecular and functional cardiac abnormalities and altered heart physiology in mouse embryos. To test if embryonic effects progress into an adult phenotype, we investigated whether Ahr ablation or TCDD exposure in utero resulted in cardiac abnormalities in adult mice long after removal of the agent. Ten-months old adult Ahr-/- and in utero TCDD-exposed Ahr+/+ mice showed sexually dimorphic abnormal cardiovascular phenotypes characterized by echocardiographic findings of hypertrophy, ventricular dilation and increased heart weight, resting heart rate and systolic and mean blood pressure, and decreased exercise tolerance. Underlying these effects, genes in signaling networks related to cardiac hypertrophy and mitochondrial function were differentially expressed. Cardiac dysfunction in mouse embryos resulting from AHR signaling disruption seems to progress into abnormal cardiac structure and function that predispose adults to cardiac disease, but while embryonic dysfunction is equally robust in males and females, the adult abnormalities are more prevalent in females, with the highest severity in Ahr-/- females. The findings reported here underscore the conclusion that AHR signaling in the developing heart is one potential target of environmental factors associated with cardiovascular disease.

  10. Development of a force-reflecting robotic platform for cardiac catheter navigation.

    Science.gov (United States)

    Park, Jun Woo; Choi, Jaesoon; Pak, Hui-Nam; Song, Seung Joon; Lee, Jung Chan; Park, Yongdoo; Shin, Seung Min; Sun, Kyung

    2010-11-01

    Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  11. Laser ablation principles and applications

    CERN Document Server

    1994-01-01

    Laser Ablation provides a broad picture of the current understanding of laser ablation and its many applications, from the views of key contributors to the field. Discussed are in detail the electronic processes in laser ablation of semiconductors and insulators, the post-ionization of laser-desorbed biomolecules, Fourier-transform mass spectroscopy, the interaction of laser radiation with organic polymers, laser ablation and optical surface damage, laser desorption/ablation with laser detection, and laser ablation of superconducting thin films.

  12. Longterm effects of cardiac mediastinal nerve cryoablation on neural inducibility of atrial fibrillation in canines.

    Science.gov (United States)

    Leiria, Tiago Luiz Luz; Glavinovic, Tamara; Armour, J Andrew; Cardinal, René; de Lima, Gustavo Glotz; Kus, Teresa

    2011-04-26

    In canines, excessive activation of select mediastinal nerve inputs to the intrinsic cardiac nervous system induces atrial fibrillation (AF). Since ablation of neural elements is proposed as an adjunct to circumferential pulmonary vein ablation for AF, we investigated the short and long-term effects of mediastinal nerve ablation on AF inducibility. Under general anesthesia, in 11 dogs several mediastinal nerve sites were identified on the superior vena cava that, when stimulated electrically during the atrial refractory period, reproducibly initiated AF. Cryoablation of one nerve site was then performed and inducibility retested early (1-2 months post Cryo; n=7) or late (4 months post Cryo; n=4). Four additional dogs that underwent a sham procedure were retested 1 to 2 months post-surgery. Stimulation induced AF at 91% of nerve sites tested in control versus 21% nerve sites early and 54% late post-ablation (both P<0.05). Fewer stimuli were required to induce AF in controls versus the Early Cryo group; this capacity returned to normal values in the Late Cryo group. AF episodes were longer in control versus the Early or Late Cryo groups. Heart rate responses to vagal or stellate ganglion stimulation, as well as to local nicotine infusion into the right coronary artery, were similar in all groups. In conclusion, focal damage to intrinsic cardiac neuronal inputs causes short-term stunning of neuronal inducibility of AF without major loss of overall adrenergic or cholinergic efferent neuronal control. That recovery of AF inducibility occurs rapidly post-surgery indicates the plasticity of intrathoracic neuronal elements to focal injury. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Microwave Ablation Compared with Radiofrequency Ablation for Breast Tissue in an Ex Vivo Bovine Udder Model

    International Nuclear Information System (INIS)

    Tanaka, Toshihiro; Westphal, Saskia; Isfort, Peter; Braunschweig, Till; Penzkofer, Tobias; Bruners, Philipp; Kichikawa, Kimihiko; Schmitz-Rode, Thomas; Mahnken, Andreas H.

    2012-01-01

    Purpose: To compare the effectiveness of microwave (MW) ablation with radiofrequency (RF) ablation for treating breast tissue in a nonperfused ex vivo model of healthy bovine udder tissue. Materials and Methods: MW ablations were performed at power outputs of 25W, 35W, and 45W using a 915-MHz frequency generator and a 2-cm active tip antenna. RF ablations were performed with a bipolar RF system with 2- and 3-cm active tip electrodes. Tissue temperatures were continuously monitored during ablation. Results: The mean short-axis diameters of the coagulation zones were 1.34 ± 0.14, 1.45 ± 0.13, and 1.74 ± 0.11 cm for MW ablation at outputs of 25W, 35W, and 45W. For RF ablation, the corresponding values were 1.16 ± 0.09 and 1.26 ± 0.14 cm with electrodes having 2- and 3-cm active tips, respectively. The mean coagulation volumes were 2.27 ± 0.65, 2.85 ± 0.72, and 4.45 ± 0.47 cm 3 for MW ablation at outputs of 25W, 35W, and 45W and 1.18 ± 0.30 and 2.29 ± 0.55 cm 3 got RF ablation with 2- and 3-cm electrodes, respectively. MW ablations at 35W and 45W achieved significantly longer short-axis diameters than RF ablations (P < 0.05). The highest tissue temperature was achieved with MW ablation at 45W (P < 0.05). On histological examination, the extent of the ablation zone in MW ablations was less affected by tissue heterogeneity than that in RF ablations. Conclusion: MW ablation appears to be advantageous with respect to the volume of ablation and the shape of the margin of necrosis compared with RF ablation in an ex vivo bovine udder.

  14. Benign thyroid nodule unresponsive to radiofrequency ablation treated with laser ablation: a case report.

    Science.gov (United States)

    Oddo, Silvia; Balestra, Margherita; Vera, Lara; Giusti, Massimo

    2018-05-11

    Radiofrequency ablation and laser ablation are safe and effective techniques for reducing thyroid nodule volume, neck symptoms, and cosmetic complaints. Therapeutic success is defined as a nodule reduction > 50% between 6 and 12 months after the procedure, but a percentage of nodules inexplicably do not respond to thermal ablation. We describe the case of a young Caucasian woman with a solid benign thyroid nodule who refused surgery and who had undergone radiofrequency ablation in 2013. The nodule did not respond in terms of either volume reduction or improvement in neck symptoms. After 2 years, given the patient's continued refusal of thyroidectomy, we proposed laser ablation. The nodule displayed a significant volume reduction (- 50% from radiofrequency ablation baseline volume, - 57% from laser ablation baseline), and the patient reported a significant improvement in neck symptoms (from 6/10 to 1/10 on a visual analogue scale). We conjecture that some benign thyroid nodules may be intrinsically resistant to necrosis when one specific ablation technique is used, but may respond to another technique. To the best of our knowledge, this is the first description of the effect of performing a different percutaneous ablation technique in a nodule that does not respond to radiofrequency ablation.

  15. Increase in Volume of Ablation Zones during Follow-up Is Highly Suggestive of Ablation Site Recurrence in Colorectal Liver Metastases Treated with Radiofrequency Ablation

    NARCIS (Netherlands)

    Kele, Petra G.; de Jong, Koert P.; van der Jagt, Eric J.

    Purpose: To test the hypothesis that volume changes of ablation zones (AZs) on successive computed tomography (CT) scans could predict ablation site recurrences (ASRs) in patients with colorectal liver metastases treated by radiofrequency (RF) ablation. Materials and Methods: RF ablation was

  16. MO-A-BRD-08: Radiosurgery Beyond Cancer: Real-Time Target Localization and Treatment Planning for Cardiac Radiosurgery Under MRI Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Ipsen, S [University of Luebeck, Luebeck, SH (Germany); University of Sydney, Camperdown (Australia); Blanck, O [CyberKnife Zentrum Norddeutschland, Guestrow, MV (Germany); Oborn, B [Illawarra Cancer Care Centre, Wollongong, NSW (Australia); Bode, F [Medical Clinic II, Section for Electrophysiology, UKSH, Luebeck, SH (Germany); Liney, G [Ingham Institute for Applied Medical Research, Liverpool, NSW (United Kingdom); Keall, P [University of Sydney, Camperdown (Australia)

    2014-06-15

    Purpose: Atrial fibrillation (AF) is the most common cardiac arrhythmia, affecting >2.5M Americans and >4.5M Europeans. AF is usually treated with minimally-invasive, time consuming catheter ablation techniques. Radiosurgery of the pulmonary veins (PV) has been proposed for AF treatment, however is challenging due to the complex respiratory and cardiac motion patterns. We hypothesize that an MRI-linac could solve the difficult real-time targeting and adaptation problem. In this study we quantified target motion ranges on cardiac MRI and analyzed the dosimetric benefits of margin reduction assuming real-time MRI tracking was applied. Methods: For the motion study, four human subjects underwent real-time cardiac MRI under free breathing. The target motion on coronal and axial cine planes was analyzed using a template matching algorithm. For the planning study, an ablation line at each PV antrum was defined as target on an AF patient scheduled for catheter ablation. Various safety margins ranging from 0mm (perfect tracking) to 8mm (untracked motion) were added to the target defining the PTV. 30Gy single fraction IMRT plans were then generated. Finally, the influence of a 1T magnetic field on treatment beam delivery was calculated using the Geant4 Monte Carlo algorithm to simulate the dosimetric impact of MRI guidance. Results: The motion study showed the mean respiratory motion of the target area on MRI was 8.4mm (SI), 1.7mm (AP) and 0.3mm (LR). Cardiac motion was small (<2mm). The planning study showed that with increasing safety margins to encompass untracked motion, dose tolerances for OARs such as the esophagus and airways were exceeded by >100%. The magnetic field had little impact on the dose distribution. Conclusion: Our results indicate that real-time MRI tracking of the PVs seems feasible. Accurate image guidance for high-dose AF radiosurgery is essential since safety margins covering untracked target motion will result in unacceptable treatment plans.

  17. Noninvasive diagnosis of suspected severe pulmonary embolism. Trans-esophageal echocardiography vs spiral CT

    International Nuclear Information System (INIS)

    Pruszczyk, P.; Torbicki, A.; Pacho, R.

    1998-01-01

    Patients with pulmonary embolism (PE) and echocardiographic signs of right ventricular over-lead have worse prognosis and may be require aggressive therapy. Unequivocal confirmation of PE is required before thrombolysis or embolectomy. This study compares the value of trans-esophageal echocardiography (TEE) and spiral CT (sCT) in direct visualization of pulmonary artery thrombo-emboli in patients with suspected PE and echocardiographic signs of right ventricular over-lead. Because of high prevalence of bilateral central pulmonary thrombo-emboli in patients with hemo-dynamically significant PE, both sCT and TEE allow its definitive confirmation in most cases. Thrombi reported by sCT distally to lobar arteries should be interpreted with caution. (author)

  18. Evaluation of optimal treatment approach in patients with early recurrence of atrial fibrillation after the first ablation procedure

    Directory of Open Access Journals (Sweden)

    В. В. Шабанов

    2015-10-01

    Full Text Available 182 patients with paroxysmal AF underwent ablation (circumferential pulmonary vein isolation with linear lesions and were monitored with an implantable cardiac monitor (Reveal XT, Medtronic. Patients were randomly assigned to group 1 or group 2. Group 1 patients were treated only with antiarrhythmic drugs for 6 weeks, with no early reablation during the 3-month postablation period. In the case of AF recurrence after the 3-month postablation period, patients underwent reablation. Group 2 patients were treated according to the onset mechanism of AF recurrences, as detected and stored by the implantable cardiac monitor: antiarrhythmic drug therapy, but no reablation if AF was not preceded by triggers; early reablation if premature atrial beats or atrial tachycardias or flutter triggered AF. All patients were followed up for 1 year to assess the sinus rhythm maintenance in each group. On 12-month follow-up examination, 67 patients (76% out of 88 in group 1 and 78 patients (92% out of 89 in group 2 had no AF recurrences (P<0,009 versus group 1. The patients with AF recurrences caused by a trigger mechanism after the first ablation demonstrated high long-term efficacy after early reablation.

  19. Voltage and pace-capture mapping of linear ablation lesions overestimates chronic ablation gap size.

    Science.gov (United States)

    O'Neill, Louisa; Harrison, James; Chubb, Henry; Whitaker, John; Mukherjee, Rahul K; Bloch, Lars Ølgaard; Andersen, Niels Peter; Dam, Høgni; Jensen, Henrik K; Niederer, Steven; Wright, Matthew; O'Neill, Mark; Williams, Steven E

    2018-04-26

    Conducting gaps in lesion sets are a major reason for failure of ablation procedures. Voltage mapping and pace-capture have been proposed for intra-procedural identification of gaps. We aimed to compare gap size measured acutely and chronically post-ablation to macroscopic gap size in a porcine model. Intercaval linear ablation was performed in eight Göttingen minipigs with a deliberate gap of ∼5 mm left in the ablation line. Gap size was measured by interpolating ablation contact force values between ablation tags and thresholding at a low force cut-off of 5 g. Bipolar voltage mapping and pace-capture mapping along the length of the line were performed immediately, and at 2 months, post-ablation. Animals were euthanized and gap sizes were measured macroscopically. Voltage thresholds to define scar were determined by receiver operating characteristic analysis as voltage, pace-capture, and ablation contact force maps. All modalities overestimated chronic gap size, by 1.4 ± 2.0 mm (ablation contact force map), 5.1 ± 3.4 mm (pace-capture), and 9.5 ± 3.8 mm (voltage mapping). Error on ablation contact force map gap measurements were significantly less than for voltage mapping (P = 0.003, Tukey's multiple comparisons test). Chronically, voltage mapping and pace-capture mapping overestimated macroscopic gap size by 11.9 ± 3.7 and 9.8 ± 3.5 mm, respectively. Bipolar voltage and pace-capture mapping overestimate the size of chronic gap formation in linear ablation lesions. The most accurate estimation of chronic gap size was achieved by analysis of catheter-myocardium contact force during ablation.

  20. Pulmonary ablation: a primer.

    Science.gov (United States)

    Roberton, Benjamin J; Liu, David; Power, Mark; Wan, John M C; Stuart, Sam; Klass, Darren; Yee, John

    2014-05-01

    Percutaneous image-guided thermal ablation is safe and efficacious in achieving local control and improving outcome in the treatment of both early stage non-small-cell lung cancer and pulmonary metastatic disease, in which surgical treatment is precluded by comorbidity, poor cardiorespiratory reserve, or unfavorable disease distribution. Radiofrequency ablation is the most established technology, but new thermal ablation technologies such as microwave ablation and cryoablation may offer some advantages. The use of advanced techniques, such as induced pneumothorax and the popsicle stick technique, or combining thermal ablation with radiotherapy, widens the treatment options available to the multidisciplinary team. The intent of this article is to provide the reader with a practical knowledge base of pulmonary ablation by concentrating on indications, techniques, and follow-up. Copyright © 2014 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  1. A Front-End ASIC with Receive Sub-array Beamforming Integrated with a 32 × 32 PZT Matrix Transducer for 3-D Transesophageal Echocardiography

    NARCIS (Netherlands)

    Chen, C.; Chen, Z.; Bera, Deep; Raghunathan, S.B.; ShabaniMotlagh, M.; Noothout, E.C.; Chang, Z.Y.; Ponte, Jacco; Prins, Christian; Vos, H.J.; Bosch, Johan G.; Verweij, M.D.; de Jong, N.; Pertijs, M.A.P.

    2017-01-01

    This paper presents a power-and area-efficient front-end application-specific integrated circuit (ASIC) that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography.

  2. Long-Term Effects of Atrial Ganglionated Plexi Ablation on Function and Structure of Sinoatrial and Atrioventricular Node in Canine.

    Science.gov (United States)

    Zhang, Ming; Wang, Ximin; Xie, Xinxing; Wang, Zhongsu; Liu, Xiaoyan; Guan, Juan; Wang, Weizong; Li, Zhan; Wang, Jiangrong; Gao, Mei; Hou, Yinglong

    2015-10-01

    Long-term effects of ganglionated plexi (GP) ablation on sinoatrial node (SAN) and atrioventricular node (AVN) remain unclear. This study is to investigate the long-term effects of ablation of cardiac anterior right GP (ARGP) and inferior right GP (IRGP) on function and structure of SAN and AVN in canine. Thirty-two dogs were randomly divided into an operated group (n = 24) and sham-operated group (n = 8). ARGP and IRGP were ablated in operated group which was randomly divided into three subgroups according to the period of evaluation after operation (1 month, 6 months, 12 months). The functional and histological characteristics of SAN and AVN, as well as the expression of connexin (Cx) 43 and Cx 45 in SAN and AVN, were evaluated before and after ablation. Resting heart rate was increased and AVN effective refractory period was prolonged and sinus node recovery time (SNRT) and corrected SNRT were shortened immediately after ablation. These changes were reverted to preablation level after 1 month. At 1 month, ventricular rate during atrial fibrillation was slowed, atria-His intervals were prolonged, and Cx43 and Cx45 expression in SAN and AVN were downregulated. At 6 months, all changes were reverted to preablation level. The histological characteristics of SAN and AVN did not change. Ablation of ARGP and IRGP has short-term effects on function and structure of SAN and AVN rather than long-term effects, which suggests that ablation of ARGP and IRGP is safe. Atrioventricular conduction dysfunction after ablation may be related to downregulated Cx43 and Cx45 expression in AVN. © 2015 Wiley Periodicals, Inc.

  3. Electrophysiology testing and catheter ablation are helpful when evaluating asymptomatic patients with Wolff-Parkinson-White pattern: the con perspective.

    Science.gov (United States)

    Skanes, Allan C; Obeyesekere, Manoj; Klein, George J

    2015-09-01

    The association between asymptomatic Wolff-Parkinson-White (WPW) syndrome and sudden cardiac death (SCD) has been well documented. The inherent properties of the accessory pathway determine the risk of SCD in WPW, and catheter ablation essentially eliminates this risk. An approach to WPW syndrome is needed that incorporates the patient's individualized considerations into the decision making. Patients must understand that there is a trade-off of a small immediate risk of an invasive approach for elimination of a small lifetime risk of the natural history of asymptomatic WPW. Clinicians can minimize the invasive risk by only performing ablation for patients with at-risk pathways. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Cardiac rehabilitation versus usual care for patients treated with catheter ablation for atrial fibrillation

    DEFF Research Database (Denmark)

    Risom, Signe S; Zwisler, Ann-Dorthe; Rasmussen, Trine Bernholdt

    2016-01-01

    ) versus 20.7mL kg(-1) min(-1), p of main effect=0.003, p of interaction between time and intervention=0.020). No significant difference between groups on Short Form-36 was found (53.8 versus 51.9 points, P=.20). Two serious adverse events (atrial fibrillation in relation to physical exercise and death...... unrelated to rehabilitation) occurred in the cardiac rehabilitation group versus one in the usual care group (death unrelated to intervention) (P=.56). In the cardiac rehabilitation group 16 patients versus 7 in the usual care group reported non-serious adverse events (P=.047). CONCLUSION: Comprehensive...

  5. Multimodality Cardiac Imaging for the Assessment of Left Atrial Function and the Association With Atrial Arrhythmias

    DEFF Research Database (Denmark)

    Olsen, Flemming Javier; Bertelsen, Litten; de Knegt, Martina Chantal

    2016-01-01

    Several cardiac imaging modalities are able to visualize the left atrium (LA) and, therefore, allow for quantification of both structural and functional properties of this cardiac chamber. In echocardiography, only the maximal LA volume is included in the assessment of diastolic function at the c......Several cardiac imaging modalities are able to visualize the left atrium (LA) and, therefore, allow for quantification of both structural and functional properties of this cardiac chamber. In echocardiography, only the maximal LA volume is included in the assessment of diastolic function...... atrial fibrillation, which will be a point of focus in this review. Pivotal cardiac magnetic resonance imaging studies have revealed high correlation between LA fibrosis and risk of atrial fibrillation recurrence after catheter ablation, and subsequent multimodality imaging studies have uncovered...... an inverse relationship between LA reservoir function and degree of LA fibrosis. This has sparked an increased interest into the application of advanced imaging modalities, including both speckle tracking echocardiography and tissue tracking by cardiac magnetic resonance imaging. Even though increasing...

  6. Management issues during HeartWare left ventricular assist device implantation and the role of transesophageal echocardiography

    Directory of Open Access Journals (Sweden)

    Sanjay Orathi Patangi

    2013-01-01

    Full Text Available Left ventricular assist devices (LVAD are increasingly used for mechanical circulatory support of patients with severe heart failure, primarily as a bridge to heart transplantation. Transesophageal echocardiography (TEE plays a major role in the clinical decision making during insertion of the devices and in the post-operative management of these patients. The detection of structural and device-related mechanical abnormalities is critical for optimal functioning of assist device. In this review article, we describe the usefulness of TEE for optimal perioperative management of patients presenting for HeartWare LVAD insertion.

  7. Ultrasound-guided percutaneous thermal ablation of hepatocellular carcinoma using microwave and radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Xu, H.-X.; Xie, X.-Y.; Lu, M.-D. E-mail: lumd@21cn.com; Chen, J.-W.; Yin, X.-Y.; Xu, Z.-F.; Liu, G.-J

    2004-01-01

    AIM: To investigate the therapeutic efficacy of thermal ablation for treatment of hepatocellular carcinoma (HCC) using microwave and radiofrequency (RF) energy application. MATERIALS AND METHODS: A total of 190 nodules in 97 patients (84 male, 13 female; mean age 53.4 years, range 24-74 years) with HCC were treated with microwave or RF ablation in the last 4 years. The applicators were introduced into the tumours under conscious analgesic sedation by intravenous administration of fentanyl citrate and droperidol and local anaesthesia in both thermal ablation procedures. The patients were then followed up with contrast-enhanced computed tomography (CT) to evaluate treatment response. Survival was analysed using the Kaplan-Meier method. RESULTS: Complete ablation was obtained in 92.6% (176/190) nodules. The complete ablation rates were 94.6% (106/112) in microwave ablation and 89.7% (70/78) in RF ablation. The complete ablation rates in tumours{<=}2.0, 2.1-3.9 and {>=}4.0 cm were 93.1, 93.8 and 86.4%, respectively. Local recurrence was found in 9.5% nodules and the rates in tumours{<=}2.0, 2.1-3.9 and {>=}4.0 cm in diameter were 3.4, 9.9 and 31.8%, respectively. In the follow-up period, 7.1% nodules ablated by microwave and 12.8% by RF presented local recurrence. The 1, 2 and 3-year distant recurrence-free survivals were 47.2, 34.9 and 31.0%, respectively. Estimated mean survival was 32 months, and 1, 2 and 3-year cumulative survivals were 75.6, 58.5, and 50.0%, respectively. One and 2 years survivals of Child-Pugh class A, B and C patients were 83.8 and 70.4%, 78.2 and 53.2%, 36.3 and 27.3%, respectively. CONCLUSION: Thermal ablation therapy by means of microwave and RF energy application is an effective and safe therapeutic technique for hepatocellular carcinoma. Large tumours can be completely ablated, but have a significantly higher risk of local recurrence at follow-up.

  8. Ultrasound-guided percutaneous thermal ablation of hepatocellular carcinoma using microwave and radiofrequency ablation

    International Nuclear Information System (INIS)

    Xu, H.-X.; Xie, X.-Y.; Lu, M.-D.; Chen, J.-W.; Yin, X.-Y.; Xu, Z.-F.; Liu, G.-J.

    2004-01-01

    AIM: To investigate the therapeutic efficacy of thermal ablation for treatment of hepatocellular carcinoma (HCC) using microwave and radiofrequency (RF) energy application. MATERIALS AND METHODS: A total of 190 nodules in 97 patients (84 male, 13 female; mean age 53.4 years, range 24-74 years) with HCC were treated with microwave or RF ablation in the last 4 years. The applicators were introduced into the tumours under conscious analgesic sedation by intravenous administration of fentanyl citrate and droperidol and local anaesthesia in both thermal ablation procedures. The patients were then followed up with contrast-enhanced computed tomography (CT) to evaluate treatment response. Survival was analysed using the Kaplan-Meier method. RESULTS: Complete ablation was obtained in 92.6% (176/190) nodules. The complete ablation rates were 94.6% (106/112) in microwave ablation and 89.7% (70/78) in RF ablation. The complete ablation rates in tumours≤2.0, 2.1-3.9 and ≥4.0 cm were 93.1, 93.8 and 86.4%, respectively. Local recurrence was found in 9.5% nodules and the rates in tumours≤2.0, 2.1-3.9 and ≥4.0 cm in diameter were 3.4, 9.9 and 31.8%, respectively. In the follow-up period, 7.1% nodules ablated by microwave and 12.8% by RF presented local recurrence. The 1, 2 and 3-year distant recurrence-free survivals were 47.2, 34.9 and 31.0%, respectively. Estimated mean survival was 32 months, and 1, 2 and 3-year cumulative survivals were 75.6, 58.5, and 50.0%, respectively. One and 2 years survivals of Child-Pugh class A, B and C patients were 83.8 and 70.4%, 78.2 and 53.2%, 36.3 and 27.3%, respectively. CONCLUSION: Thermal ablation therapy by means of microwave and RF energy application is an effective and safe therapeutic technique for hepatocellular carcinoma. Large tumours can be completely ablated, but have a significantly higher risk of local recurrence at follow-up

  9. Ablation threshold and ablation mechanism transition of polyoxymethylene irradiated by CO2 laser.

    Science.gov (United States)

    Li, Gan; Cheng, Mousen; Li, Xiaokang

    2016-09-01

    Polyoxymethylene (POM) decomposes gradually as it is heated up by the irradiation of CO2 laser; the long-chain molecules of POM are broken into short chains, which leads to the lowering of the melting point and the critical temperature of the ablation products. When the product temperature is above the melting point, ablation comes up in the way of vaporization; when the product temperature is higher than the critical temperature, all liquid products are transformed into gas instantly and the ablation mechanism is changed. The laser fluence at which significant ablation is observed is defined as the ablation threshold, and the fluence corresponding to the ablation mechanism changing is denoted as the flyover threshold. In this paper, random pyrolysis is adopted to describe the pyrolytic decomposition of POM, and consequently, the components of the pyrolysis products under different pyrolysis rates are acquired. The Group Contribution method is used to count the thermodynamic properties of the pyrolysis products, and the melting point and the critical temperature of the product mixture are obtained by the Mixing Law. The Knudsen layer relationship is employed to evaluate the ablation mass removal when the product temperature is below the critical temperature. The gas dynamics conservation laws associated with the Jouguet condition are used to calculate the mass removal when the product temperature is higher than the critical temperature. Based on the model, a set of simulations for various laser intensities and lengths are carried out to generalize the relationships between the thresholds and the laser parameters. Besides the ablated mass areal density, which fits the experimental data quite well, the ablation temperature, pyrolysis rate, and product components are also discussed for a better understanding of the ablation mechanism of POM.

  10. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.

    Science.gov (United States)

    Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil

    2012-05-01

    Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  11. Intracardiac echo-facilitated 3D electroanatomical mapping of ventricular arrhythmias from the papillary muscles: assessing the 'fourth dimension' during ablation.

    Science.gov (United States)

    Proietti, Riccardo; Rivera, Santiago; Dussault, Charles; Essebag, Vidal; Bernier, Martin L; Ayala-Paredes, Felix; Badra-Verdu, Mariano; Roux, Jean-François

    2017-01-01

    Ventricular arrhythmias (VA) originating from a papillary muscle (PM) have recently been described as a distinct clinical entity with peculiar features that make its treatment with catheter ablation challenging. Here, we report our experience using an intracardiac echo-facilitated 3D electroanatomical mapping approach in a case series of patients undergoing ablation for PM VA. Sixteen patients who underwent catheter ablation for ventricular tachycardia (VT) or symptomatic premature ventricular contractions originating from left ventricular PMs were included in the study. A total of 24 procedures (mean 1.5 per patient) were performed: 15 using a retrograde aortic approach and 9 using a transseptal approach. Integrated intracardiac ultrasound for 3D electroanatomical mapping was used in 15 of the 24 procedures. The posteromedial PM was the most frequent culprit for the clinical arrhythmia, and the body was the part of the PM most likely to be the successful site for ablation. The site of ablation was identified based on the best pace map matching the clinical arrhythmia and the site of earliest the activation. At a mean follow-up of 10.5 ± 7 months, only two patients had recurrent arrhythmias following a repeat ablation procedure. An echo-facilitated 3D electroanatomical mapping allows for real-time creation of precise geometries of cardiac chambers and endocavitary structures. This is useful during procedures such as catheter ablation of VAs originating from PMs, which require detailed representation of anatomical landmarks. Routine adoption of this technique should be considered to improve outcomes of PM VA ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  12. Radiofrequency ablation of pulmonary tumors

    Energy Technology Data Exchange (ETDEWEB)

    Crocetti, Laura, E-mail: l.crocetti@med.unipi.i [Division of Diagnostic Imaging and Intervention, Department of Liver Transplants, Hepatology and Infectious Diseases, Pisa University School of Medicine (Italy); Lencioni, Riccardo [Division of Diagnostic Imaging and Intervention, Department of Liver Transplants, Hepatology and Infectious Diseases, Pisa University School of Medicine (Italy)

    2010-07-15

    The development of image-guided percutaneous techniques for local tumor ablation has been one of the major advances in the treatment of solid tumors. Among these methods, radiofrequency (RF) ablation is currently established as the primary ablative modality at most institutions. RF ablation is accepted as the best therapeutic choice for patients with early-stage hepatocellular carcinoma when liver transplantation or surgical resection are not suitable options and is considered as a viable alternate to surgery for inoperable patients with limited hepatic metastatic disease, especially from colorectal cancer. Recently, RF ablation has been demonstrated to be a safe and valuable treatment option for patients with unresectable or medically inoperable lung malignancies. Resection should remain the standard therapy for non-small cell lung cancer (NSCLC) but RF ablation may be better than conventional external-beam radiation for the treatment of the high-risk individual with NSCLC. Initial favourable outcomes encourage combining radiotherapy and RF ablation, especially for treating larger tumors. In the setting of colorectal cancer lung metastases, survival rates provided by RF ablation in selected patients, are substantially higher than those obtained with any chemotherapy regimens and provide indirect evidence that RF ablation therapy improves survival in patients with limited lung metastatic disease.

  13. Ablation of the Right Cardiac Vagus Nerve Reduces Acetylcholine Content without Changing the Inflammatory Response during Endotoxemia

    Directory of Open Access Journals (Sweden)

    Konstanze Plaschke

    2018-02-01

    Full Text Available Acetylcholine is the main transmitter of the parasympathetic vagus nerve. According to the cholinergic anti-inflammatory pathway (CAP concept, acetylcholine has been shown to be important for signal transmission within the immune system and also for a variety of other functions throughout the organism. The spleen is thought to play an important role in regulating the CAP. In contrast, the existence of a “non-neuronal cardiac cholinergic system” that influences cardiac innervation during inflammation has been hypothesized, with recent publications introducing the heart instead of the spleen as a possible interface between the immune and nervous systems. To prove this hypothesis, we investigated whether selectively disrupting vagal stimulation of the right ventricle plays an important role in rat CAP regulation during endotoxemia. We performed a selective resection of the right cardiac branch of the Nervus vagus (VGX with a corresponding sham resection in vehicle-injected and endotoxemic rats. Rats were injected with lipopolysaccharide (LPS, 1 mg/kg body weight, intravenously and observed for 4 h. Intraoperative blood gas analysis was performed, and hemodynamic parameters were assessed using a left ventricular pressure-volume catheter. Rat hearts and blood were collected, and the expression and concentration of proinflammatory cytokines using quantitative reverse transcription polymerase chain reaction and enzyme-linked immunosorbent assay were measured, respectively. Four hours after injection, LPS induced a marked deterioration in rat blood gas parameters such as pH value, potassium, base excess, glucose, and lactate. The mean arterial blood pressure and the end-diastolic volume had decreased significantly. Further, significant increases in blood cholinesterases and in proinflammatory (IL-1β, IL-6, TNF-α cytokine concentration and gene expression were obtained. Right cardiac vagus nerve resection (VGX led to a marked decrease in heart

  14. Ablation of the Right Cardiac Vagus Nerve Reduces Acetylcholine Content without Changing the Inflammatory Response during Endotoxemia.

    Science.gov (United States)

    Plaschke, Konstanze; Do, Thuc Quyen Monica; Uhle, Florian; Brenner, Thorsten; Weigand, Markus A; Kopitz, Jürgen

    2018-02-01

    Acetylcholine is the main transmitter of the parasympathetic vagus nerve. According to the cholinergic anti-inflammatory pathway (CAP) concept, acetylcholine has been shown to be important for signal transmission within the immune system and also for a variety of other functions throughout the organism. The spleen is thought to play an important role in regulating the CAP. In contrast, the existence of a "non-neuronal cardiac cholinergic system" that influences cardiac innervation during inflammation has been hypothesized, with recent publications introducing the heart instead of the spleen as a possible interface between the immune and nervous systems. To prove this hypothesis, we investigated whether selectively disrupting vagal stimulation of the right ventricle plays an important role in rat CAP regulation during endotoxemia. We performed a selective resection of the right cardiac branch of the Nervus vagus (VGX) with a corresponding sham resection in vehicle-injected and endotoxemic rats. Rats were injected with lipopolysaccharide (LPS, 1 mg/kg body weight, intravenously) and observed for 4 h. Intraoperative blood gas analysis was performed, and hemodynamic parameters were assessed using a left ventricular pressure-volume catheter. Rat hearts and blood were collected, and the expression and concentration of proinflammatory cytokines using quantitative reverse transcription polymerase chain reaction and enzyme-linked immunosorbent assay were measured, respectively. Four hours after injection, LPS induced a marked deterioration in rat blood gas parameters such as pH value, potassium, base excess, glucose, and lactate. The mean arterial blood pressure and the end-diastolic volume had decreased significantly. Further, significant increases in blood cholinesterases and in proinflammatory (IL-1β, IL-6, TNF-α) cytokine concentration and gene expression were obtained. Right cardiac vagus nerve resection (VGX) led to a marked decrease in heart acetylcholine

  15. Ablative skin resurfacing.

    Science.gov (United States)

    Agrawal, Nidhi; Smith, Greg; Heffelfinger, Ryan

    2014-02-01

    Ablative laser resurfacing has evolved as a safe and effective treatment for skin rejuvenation. Although traditional lasers were associated with significant thermal damage and lengthy recovery, advances in laser technology have improved safety profiles and reduced social downtime. CO2 lasers remain the gold standard of treatment, and fractional ablative devices capable of achieving remarkable clinical improvement with fewer side effects and shorter recovery times have made it a more practical option for patients. Although ablative resurfacing has become safer, careful patient selection and choice of suitable laser parameters are essential to minimize complications and optimize outcomes. This article describes the current modalities used in ablative laser skin resurfacing and examines their efficacy, indications, and possible side effects. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

    Energy Technology Data Exchange (ETDEWEB)

    Ma Yingliang; Housden, R. James; Razavi, Reza; Rhode, Kawal S. [Division of Imaging Sciences and Biomedical Engineering, King' s College London, London SE1 7EH (United Kingdom); Gogin, Nicolas; Cathier, Pascal [Medisys Research Group, Philips Healthcare, Paris 92156 (France); Gijsbers, Geert [Interventional X-ray, Philips Healthcare, Best 5680 DA (Netherlands); Cooklin, Michael; O' Neill, Mark; Gill, Jaswinder; Rinaldi, C. Aldo [Department of Cardiology, Guys and St. Thomas' Hospitals NHS Foundation Trust, London SE1 7EH (United Kingdom)

    2013-07-15

    Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to 100%, 99

  17. Low Left Atrial Compliance Contributes to the Clinical Recurrence of Atrial Fibrillation after Catheter Ablation in Patients with Structurally and Functionally Normal Heart.

    Science.gov (United States)

    Park, Junbeom; Yang, Pil-sung; Kim, Tae-Hoon; Uhm, Jae-Sun; Kim, Joung-Youn; Joung, Boyoung; Lee, Moon-Hyoung; Hwang, Chun; Pak, Hui-Nam

    2015-01-01

    Stiff left atrial (LA) syndrome was initially reported in post-cardiac surgery patients and known to be associated with low LA compliance. We investigated the physiological and clinical implications of LA compliance by estimating LA pulse pressure (LApp) among patients with atrial fibrillation (AF) and structurally and functionally normal heart. Among 1038 consecutive patients with LA pressure measurements before AF ablation, we included 334 patients with structurally and functionally normal heart (81.7% male, 54.1±10.6 years, 77.0% paroxysmal AF) after excluding those with hypertension, diabetes, and previous ablation or cardiac surgery. We measured LApp (peak-nadir LA pressure) at the beginning of the ablation procedure and compared the values with clinical parameters and the AF recurrence rate. AF patients with normal heart were younger and more frequently male and had paroxysmal AF, a lower body mass index, and a lower LApp compared to others (all p<0.05). Based on the median value, the low LA compliance group (LApp≥13 mmHg) had a smaller LA volume index and lower LA voltage (all p<0.05) compared to the high LA compliance group. During a mean follow-up of 16.7±11.8 months, low LA compliance was independently associated with two fold-higher risk of clinical AF recurrence (HR:2.202; 95%CI:1.077-4.503; p = 0.031). Low LA compliance, as determined by an elevated LApp, was associated with a smaller LA volume index and lower LA voltage and independently associated with higher clinical recurrence after catheter ablation in AF patients with structurally and functionally normal heart.

  18. Therapeutic effect of radiofrequency ablation on children with supraventricular tachycardia and the risk factors for postoperative recurrence.

    Science.gov (United States)

    Li, Chunli; Jia, Libo; Wang, Zhenzhou; Niu, Ling; An, Xinjiang

    2018-05-01

    The present study investigated the therapeutic effect of radiofrequency ablation on children with supraventricular tachycardia (SVT), and explored the risk factors for postoperative recurrence. A total of 312 patients with pediatric SVT were selected in the Affiliated Children's Hospital of Xuzhou Medical University from April, 2011 to March, 2017. All the patients were subjected to radiofrequency ablation, and clinical data were retrospectively analyzed. Tilt table test was performed before and after treatment, and heart rate, systolic and diastolic blood pressure before and after treatment were compared. Plasma levels of D-dimer (D-D), platelet α-granule membrane protein (GMP-140) and thrombin-antithrombin III complex (TAT) were detected by enzyme-linked immunosorbent assay before treatment, immediately after radiofrequency oblation, and at 1, 3 and 7 days after treatment. Treatment outcomes were compared between the atrioventricular reentrant tachycardia (AVRT) and atrioventricular nodal reentrant tachycardia (AVNRT) groups. Risk factors for postoperative recurrence were analyzed. Supine position heart rate after treatment was not significantly different from that before treatment (P>0.05), while the upright position heart rate was significantly increased after treatment (P0.05). No significant difference in radiofrequency ablation rate, recurrence rate and incidence of complications were found between the AVRT and AVNRT groups (P>0.05). After radiofrequency, the levels of D-D, GMP-140 and TAT ablation showed an upward trend, but decreased at day 7 to reach preoperative levels. Logistic regression analysis revealed that residual slow pathway (OR=6.718, P=0.005) and inaccurate targeting (OR=2.815, P=0.007) were independent risk factors for postoperative recurrence (Pradiofrequency ablation can damage the cardiac vagal nerve, resulting in an increase in the heart rate after ablation during the course of the tilt table test and changed hemagglutination state

  19. Sarcospan Regulates Cardiac Isoproterenol Response and Prevents Duchenne Muscular Dystrophy-Associated Cardiomyopathy.

    Science.gov (United States)

    Parvatiyar, Michelle S; Marshall, Jamie L; Nguyen, Reginald T; Jordan, Maria C; Richardson, Vanitra A; Roos, Kenneth P; Crosbie-Watson, Rachelle H

    2015-12-23

    Duchenne muscular dystrophy is a fatal cardiac and skeletal muscle disease resulting from mutations in the dystrophin gene. We have previously demonstrated that a dystrophin-associated protein, sarcospan (SSPN), ameliorated Duchenne muscular dystrophy skeletal muscle degeneration by activating compensatory pathways that regulate muscle cell adhesion (laminin-binding) to the extracellular matrix. Conversely, loss of SSPN destabilized skeletal muscle adhesion, hampered muscle regeneration, and reduced force properties. Given the importance of SSPN to skeletal muscle, we investigated the consequences of SSPN ablation in cardiac muscle and determined whether overexpression of SSPN into mdx mice ameliorates cardiac disease symptoms associated with Duchenne muscular dystrophy cardiomyopathy. SSPN-null mice exhibited cardiac enlargement, exacerbated cardiomyocyte hypertrophy, and increased fibrosis in response to β-adrenergic challenge (isoproterenol; 0.8 mg/day per 2 weeks). Biochemical analysis of SSPN-null cardiac muscle revealed reduced sarcolemma localization of many proteins with a known role in cardiomyopathy pathogenesis: dystrophin, the sarcoglycans (α-, δ-, and γ-subunits), and β1D integrin. Transgenic overexpression of SSPN in Duchenne muscular dystrophy mice (mdx(TG)) improved cardiomyofiber cell adhesion, sarcolemma integrity, cardiac functional parameters, as well as increased expression of compensatory transmembrane proteins that mediate attachment to the extracellular matrix. SSPN regulates sarcolemmal expression of laminin-binding complexes that are critical to cardiac muscle function and protects against transient and chronic injury, including inherited cardiomyopathy. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  20. Integration of cardiac computed tomography into pulmonary vein isolation in patients with paroxysmal atrial fibrillation; Integration einer praeinterventionellen Computertomografie des Herzens in die therapeutische Pulmonalvenenisolation bei Patienten mit paroxysmalem Vorhofflimmern

    Energy Technology Data Exchange (ETDEWEB)

    Weber, T.F. [Abt. Radiologie, Deutsches Krebsforschungszentrum, Heidelberg (Germany); Klemm, H.; Willems, S. [Klinik und Poliklinik fuer Kardiologie und Angiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Koops, A.; Adam, G.; Begemann, P.G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Nagel, H.D. [Philips Medizin Systeme GmbH, Hamburg (Germany)

    2007-12-15

    Purpose: Detailed anatomic information of the left atrium is necessary for securely performing radiofrequency ablation of atrial fibrillation-triggering ectopies in the pulmonary vein ostia. In this study the impact of a preinterventionally acquired cardiac computed tomography (CT) on pulmonary vein isolation (PVI) was assessed. Materials and methods: Examinations of 54 patients with paroxysmal atrial fibrillation undergoing PVI were analyzed. In 27 patients a supplementary cardiac CT was obtained prior to PVI (CT group, 12 women, 15 men, 59.7 {+-} 9.9 years of age): 16 x 1.5 mm collimation, 0.2 pitch, 120 kV tube voltage, 400 effective mAs. The fluoroscopy time, effective dose and quantity of radiofrequency (RF) pulses of the following catheter ablation were compared to 27 patients undergoing stand-alone PVI (11 women, 16 men, 62.0 {+-} 9.9 years of age). Mann-Whitney tests served for statistical comparison. Results: CT datasets were successfully integrated into the ablation procedure of each patient in the CT group. The mean quantity of RF pulses was significantly lower in the CT group (22.1 {+-} 8.0 vs. 29.1 {+-} 11.9, p = 0.030), and a significant reduction of fluoroscopy time was found (41.8 {+-} 12.0 min vs. 51.2 {+-} 16.0 min, p = 0.005). Effective doses of the catheter ablation differed in an equivalent dimension but altogether not significantly (14.9 {+-} 10.0 mSv vs. 20.0 {+-} 16.0 mSv, p = 0.203). The mean additive effective dose of the cardiac CT was 85 {+-} 0.3 mSv. (orig.)

  1. Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography.

    NARCIS (Netherlands)

    Ng, A.C.; Delgado, V.; Kley, F. van der; Shanks, M.; Veire, N.R. van de; Bertini, M.; Nucifora, G.; Bommel, R.J. van; Tops, L.F.; Weger, A. de; Tavilla, G.; Roos, A. de; Kroft, L.J.; Leung, D.Y.; Schuijf, J.; Schalij, M.J.; Bax, J.J.

    2010-01-01

    BACKGROUND: 3D transesophageal echocardiography (TEE) may provide more accurate aortic annular and left ventricular outflow tract (LVOT) dimensions and geometries compared with 2D TEE. We assessed agreements between 2D and 3D TEE measurements with multislice computed tomography (MSCT) and changes in

  2. Useful clinical features for the selection of ideal patients with strial fibrillation for mapping and catheter ablation

    Directory of Open Access Journals (Sweden)

    Mehta Niraj

    2002-01-01

    Full Text Available OBJECTIVE: To identify useful clinical characteristics for selecting patients eligible for mapping and ablation of atrial fibrillation. METHODS: We studied 9 patients with atrial fibrillation, without structural heart disease, associated with: 1 antiarrhythmic drugs, 2 symptoms of low cardiac output, and 3 intention to treat. Seven patients had paroxysmal atrial fibrillation and 2 had recurrent atrial fibrillation. RESULTS: In the 6 patients who underwent mapping (all had paroxysmal atrial fibrillation, catheter ablation was successfully carried out in superior pulmonary veins in 5 patients (the first 3 in the left superior pulmonary vein and the last 2 in the right superior pulmonary vein. One patient experienced a recurrence of atrial fibrillation after 10 days. We observed that patients who had short episodes of atrial fibrillation on 24-hour Holter monitoring before the procedure were those in whom mapping the focus of tachycardia was possible. Tachycardia was successfully suppressed in 4 of 6 patients. The cause of failure was due to the impossibility of maintaining sinus rhythm long enough for efficient mapping. CONCLUSION: Patients experiencing short episodes of atrial fibrillation during 24-hour Holter monitoring were the most eligible for mapping and ablation, with a final success rate of 66%, versus the global success rate of 44%. Patients with persistent atrial fibrillation were not good candidates for focal ablation.

  3. A hybrid stimulation strategy for suppression of spiral waves in cardiac tissue

    Energy Technology Data Exchange (ETDEWEB)

    Xu Binbin, E-mail: xubinbin@hotmail.fr [LE2I, CNRS UMR 5158, Universite de Bourgogne, Dijon (France); Jacquir, Sabir, E-mail: sjacquir@u-bourgogne.fr [LE2I, CNRS UMR 5158, Universite de Bourgogne, Dijon (France); Laurent, Gabriel; Bilbault, Jean-Marie [LE2I, CNRS UMR 5158, Universite de Bourgogne, Dijon (France); Binczak, Stephane, E-mail: stbinc@u-bourgogne.fr [LE2I, CNRS UMR 5158, Universite de Bourgogne, Dijon (France)

    2011-08-15

    Highlights: > Simulation of a cardiac tissue by a modified 2D FitzHugh-Nagumo model. > Stimulation of monophasic impulsions from a grid of electrodes to the cardiac tissue. > Propose a method by modifying the tissue's sodium channels and electrical stimulation. > The method leading to suppress spiral waves without generating new ones. > Optimal parameters of a successful suppression of spiral waves are investigated. - Abstract: Atrial fibrillation (AF) is the most common cardiac arrhythmia whose mechanisms are thought to be mainly due to the self perpetuation of spiral waves (SW). To date, available treatment strategies (antiarrhythmic drugs, radiofrequency ablation of the substrate, electrical cardioversion) to restore and to maintain a normal sinus rhythm have limitations and are associated with AF recurrences. The aim of this study was to assess a way of suppressing SW by applying multifocal electrical stimulations in a simulated cardiac tissue using a 2D FitzHugh-Nagumo model specially convenient for AF investigations. We identified stimulation parameters for successful termination of SW. However, SW reinduction, following the electrical stimuli, leads us to develop a hybrid strategy based on sodium channel modification for the simulated tissue.

  4. Prophylactic accessory-pathway ablation in asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern.

    Science.gov (United States)

    Ozenc, S; Iscen, S; Kibrisli, E; Tok, D; Parlak, A; Altinel, O; Altinel, S

    2014-01-01

    The optimal approach is controversial in asymptomatic patients who are coincidentally found to have evidence of an accessory pathway (AP) on an ECG. The risk of sudden cardiac death (SCD) is low, and the risk of developing symptoms also appears to be low, although a wide range of incidences have been reported. In our trial, we tested the hypothesis that if prophylactic accessory-pathway ablation performed at the time of the initial electrophysiological testing would improve the long-term outcome in asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern. Recruitment of patients began on February 1, 2004, and ended on February 5, 2009. All 110 asymptomatic patients were hospitalized and underwent electrophysiological testing the same day to assess the inducibility of atrioventricular reciprocating tachycardia. The anterograde effective refractory period of the accessory pathway was defined as the longest coupling interval at which anterograde block in the bypass tract was observed. For the statistical analysis, the statistical software SPSS version 15.0 for Windows (SPSS Inc., Chicago, IL, USA). Of 110 asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern, 80 patients were ablated. Ablation group consisted of these patients. Control group consisted of remaining 30 and were divided into two groups according to the anterograde effective refractory period of the accessory pathway. There was no significant difference between three groups in terms of arrhythmic events (p: 0.58). Asymptomatic patients with the Wolff-Parkinson-White syndrome do not require prophylactic ablation, since they remain asymptomatic for many years.

  5. Percutaneous autonomic neural modulation: A novel technique to treat cardiac arrhythmia

    International Nuclear Information System (INIS)

    DeSimone, Christopher V.; Madhavan, Malini; Venkatachalam, Kalpathi L.; Knudson, Mark B.; Asirvatham, Samuel J.

    2013-01-01

    Ablation and anti-arrhythmic medications have shown promise but have been met with varying success and unwanted side effects such as myocardial injury, arrhythmias, and morbidity from invasive surgical intervention. The answer to improving efficacy of ablation may include modulation of the cardiac aspect of the autonomic nervous system. Our lab has developed a novel approach and device to navigate the oblique sinus and to use DC current and saline/alcohol irrigation to selectively stimulate and block the autonomic ganglia found on the epicardial side of the heart. This novel approach minimizes myocardial damage from thermal injury and provides a less invasive and targeted approach. For feasibility, proof-of-concept, and safety monitoring, we carried out canine studies to test this novel application. Our results suggest a safer and less invasive way of modulating arrhythmogenic substrate that may lead to improved treatment of AF in humans

  6. Percutaneous autonomic neural modulation: A novel technique to treat cardiac arrhythmia

    Energy Technology Data Exchange (ETDEWEB)

    DeSimone, Christopher V.; Madhavan, Malini [Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, MN (United States); Venkatachalam, Kalpathi L. [Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Jacksonville, FL (United States); Knudson, Mark B. [Mayo Clinic, Rochester, MN (United States); EnteroMedics, EnteroMedics, St. Paul, MN (United States); Asirvatham, Samuel J., E-mail: asirvatham.samuel@mayo.edu [Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, MN (United States); Pediatric Cardiology, Department of Pediatric and Adolescent Medicine, Mayo Clinic, Rochester, MN (United States)

    2013-05-15

    Ablation and anti-arrhythmic medications have shown promise but have been met with varying success and unwanted side effects such as myocardial injury, arrhythmias, and morbidity from invasive surgical intervention. The answer to improving efficacy of ablation may include modulation of the cardiac aspect of the autonomic nervous system. Our lab has developed a novel approach and device to navigate the oblique sinus and to use DC current and saline/alcohol irrigation to selectively stimulate and block the autonomic ganglia found on the epicardial side of the heart. This novel approach minimizes myocardial damage from thermal injury and provides a less invasive and targeted approach. For feasibility, proof-of-concept, and safety monitoring, we carried out canine studies to test this novel application. Our results suggest a safer and less invasive way of modulating arrhythmogenic substrate that may lead to improved treatment of AF in humans.

  7. Percutaneous thermal ablation of renal neoplasms

    International Nuclear Information System (INIS)

    Tacke, J.; Mahnken, A.H.; Guenther, R.W.

    2005-01-01

    Due to modern examination techniques such as multidetector computed tomography and high-field magnetic resonance imaging, the detection rate of renal neoplasms is continually increasing. Even though tumors exceeding 4 cm in diameter rarely metastasize, all renal lesions that are possible neoplasms should be treated. Traditional treatment techniques include radical nephrectomy or nephron-sparing resection, which are increasingly performed laparoscopically. Modern thermal ablation techniques such as hyperthermal techniques like radiofrequency ablation RFA, laser induced thermal ablation LITT, focused ultrasound FUS and microwave therapy MW, as well as hypothermal techniques (cryotherapy) may be a useful treatment option for patients who are unfit for or refuse surgical resection. Cryotherapy is the oldest and best known thermal ablation technique and can be performed laparoscopically or percutaneously. Since subzero temperatures have no antistyptic effect, additional maneuvers must be performed to control bleeding. Percutaneous cryotherapy of renal tumors is a new and interesting method, but experience with it is still limited. Radiofrequency ablation is the most frequently used method. Modern probe design allows volumes between 2 and 5 cm in diameter to be ablated. Due to hyperthermal tract ablation, the procedure is deemed to be safe and has a low complication rate. Although there are no randomized comparative studies to open resection, the preliminary results for renal RFA are promising and show RFA to be superior to other thermal ablation techniques. Clinical success rates are over 90% for both, cryo- and radiofrequency ablation. Whereas laser induced thermal therapy is established in hepatic ablation, experience is minimal with respect to renal application. For lesions of more than 2 cm in diameter, additional cooling catheters are required. MR thermometry offers temperature control during ablation. Microwave ablation is characterized by small ablation volumes

  8. Extension of adrenocortical carcinoma into the right atrium – echocardiographic diagnosis: A case report

    Directory of Open Access Journals (Sweden)

    Rozenman Yoseph

    2003-05-01

    Full Text Available Abstract Background Adrenocortical carcinoma is a rare, highly malignant tumor. Cardiac involvement of the tumor is very rare. Echocardiography facilitates the evaluation of the cardiac involvement of the tumor. Case Presentation We describe a patient with an adrenal tumor. Transthoracic echo showed its extension into the right atrium. Accordingly, a combined abdominal and cardiac operation was performed, monitored by transesophageal echocardiography. Conclusion This case highlights the importance of echocardiography in revealing the cardiac involvement by this tumor and in planning the operative procedure.

  9. Direct measurement of the lethal isotherm for radiofrequency ablation of myocardial tissue.

    Science.gov (United States)

    Wood, Mark; Goldberg, Scott; Lau, Melissa; Goel, Aneesh; Alexander, Daniel; Han, Frederick; Feinstein, Shawn

    2011-06-01

    The lethal isotherm for radiofrequency catheter ablation of cardiac myocardium is widely accepted to be 50°C, but this has not been directly measured. The purpose of this study was to directly measure the tissue temperature at the edge of radiofrequency lesions in real time using infrared thermal imaging. Fifteen radiofrequency lesions of 6 to 240 seconds in duration were applied to the left ventricular surface of isolated perfused pig hearts. At the end of radiofrequency delivery, a thermal image of the tissue surface was acquired with an infrared camera. The lesion was then stained and an optical image of the lesion was obtained. The thermal and optical images were electronically merged to allow determination of the tissue temperature at the edge of the lesion at the end of radiofrequency delivery. By adjusting the temperature overlay display to conform with the edge of the radiofrequency lesion, the lethal isotherm was measured to be 60.6°C (interquartile ranges, 59.7° to 62.4°C; range, 58.1° to 64.2°C). The areas encompassed by the lesion border in the optical image and the lethal isotherm in the thermal image were statistically similar and highly correlated (Spearman ρ=0.99, Pradiofrequency delivery or to lesion size (both P>0.64). The areas circumscribed by 50°C isotherms were significantly larger than the areas of the lesions on optical imaging (P=0.002). By direct measurement, the lethal isotherm for cardiac myocardium is near 61°C for radiofrequency energy deliveries radiofrequency ablation is important to clinical practice as well as mathematical modeling of radiofrequency lesions.

  10. Laboratory Simulations of Micrometeoroid Ablation

    Science.gov (United States)

    Thomas, Evan Williamson

    Each day, several tons of meteoric material enters Earth's atmosphere, the majority of which consist of small dust particles (micrometeoroids) that completely ablate at high altitudes. The dust input has been suggested to play a role in a variety of phenomena including: layers of metal atoms and ions, nucleation of noctilucent clouds, effects on stratospheric aerosols and ozone chemistry, and the fertilization of the ocean with bio-available iron. Furthermore, a correct understanding of the dust input to the Earth provides constraints on inner solar system dust models. Various methods are used to measure the dust input to the Earth including satellite detectors, radar, lidar, rocket-borne detectors, ice core and deep-sea sediment analysis. However, the best way to interpret each of these measurements is uncertain, which leads to large uncertainties in the total dust input. To better understand the ablation process, and thereby reduce uncertainties in micrometeoroid ablation measurements, a facility has been developed to simulate the ablation of micrometeoroids in laboratory conditions. An electrostatic dust accelerator is used to accelerate iron particles to relevant meteoric velocities (10-70 km/s). The particles are then introduced into a chamber pressurized with a target gas, and they partially or completely ablate over a short distance. An array of diagnostics then measure, with timing and spatial resolution, the charge and light that is generated in the ablation process. In this thesis, we present results from the newly developed ablation facility. The ionization coefficient, an important parameter for interpreting meteor radar measurements, is measured for various target gases. Furthermore, experimental ablation measurements are compared to predictions from commonly used ablation models. In light of these measurements, implications to the broader context of meteor ablation are discussed.

  11. Mammalian enabled (Mena) is a critical regulator of cardiac function.

    Science.gov (United States)

    Aguilar, Frédérick; Belmonte, Stephen L; Ram, Rashmi; Noujaim, Sami F; Dunaevsky, Olga; Protack, Tricia L; Jalife, Jose; Todd Massey, H; Gertler, Frank B; Blaxall, Burns C

    2011-05-01

    Mammalian enabled (Mena) of the Drosophila enabled/vasodilator-stimulated phosphoprotein gene family is a cytoskeletal protein implicated in actin regulation and cell motility. Cardiac Mena expression is enriched in intercalated discs (ICD), the critical intercellular communication nexus between adjacent muscle cells. We previously identified Mena gene expression to be a key predictor of human and murine heart failure (HF). To determine the in vivo function of Mena in the heart, we assessed Mena protein expression in multiple HF models and characterized the effects of genetic Mena deletion on cardiac structure and function. Immunoblot analysis revealed significant upregulation of Mena protein expression in left ventricle tissue from patients with end-stage HF, calsequestrin-overexpressing mice, and isoproterenol-infused mice. Characterization of the baseline cardiac function of adult Mena knockout mice (Mena(-/-)) via echocardiography demonstrated persistent cardiac dysfunction, including a significant reduction in percent fractional shortening compared with wild-type littermates. Electrocardiogram PR and QRS intervals were significantly prolonged in Mena(-/-) mice, manifested by slowed conduction on optical mapping studies. Ultrastructural analysis of Mena(-/-) hearts revealed disrupted organization and widening of ICD structures, mislocalization of the gap junction protein connexin 43 (Cx43) to the lateral borders of cardiomyoycytes, and increased Cx43 expression. Furthermore, the expression of vinculin (an adherens junction protein) was significantly reduced in Mena(-/-) mice. We report for the first time that genetic ablation of Mena results in cardiac dysfunction, highlighted by diminished contractile performance, disrupted ICD structure, and slowed electrical conduction.

  12. Thermal Ablation of T1c Renal Cell Carcinoma: A Comparative Assessment of Technical Performance, Procedural Outcome, and Safety of Microwave Ablation, Radiofrequency Ablation, and Cryoablation.

    Science.gov (United States)

    Zhou, Wenhui; Arellano, Ronald S

    2018-04-06

    To evaluate perioperative outcomes of thermal ablation with microwave (MW), radiofrequency (RF), and cryoablation for stage T1c renal cell carcinoma (RCC). A retrospective analysis of 384 patients (mean age, 71 y; range, 22-88 y) was performed between October 2006 and October 2016. Mean radius, exophytic/endophytic, nearness to collecting system or sinus, anterior/posterior, and location relative to polar lines; preoperative aspects and dimensions used for anatomic classification; and centrality index scores were 6.3, 7.9, and 2.7, respectively. Assessment of pre- and postablation serum blood urea nitrogen, creatinine, and estimated glomerular filtration rate was performed to assess functional outcomes. Linear regression analyses were performed to compare sedation medication dosages among the three treatment cohorts. Univariable and multivariable logistic regression analyses were performed to compare rates of residual disease and complications among treatment modalities. A total of 437 clinical stage T1N0M0 biopsy-proven RCCs measuring 1.2-6.9 cm were treated with computed tomography (CT)-guided MW ablation (n = 44; 10%), RF ablation (n = 347; 79%), or cryoablation (n = 46; 11%). There were no significant differences in patient demographic or tumor characteristics among cohorts. Complication rates and immediate renal function changes were similar among the three ablation modalities (P = .46 and P = .08, respectively). MW ablation was associated with significantly decreased ablation time (P < .05), procedural time (P < .05), and dosage of sedative medication (P < .05) compared with RF ablation and cryoablation. CT-guided percutaneous MW ablation is comparable to RF ablation or cryoablation for the treatment of stage T1N0M0 RCC with regard to treatment response and is associated with shorter treatment times and less sedation than RF ablation or cryoablation. In addition, the safety profile of CT-guided MW ablation is noninferior to those of RF ablation or

  13. Temperature-controlled radiofrequency ablation of cardiac tissue: an in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, A

    1999-01-01

    A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available for the frequently used...... temperature-controlled mode. The purpose of the present experimental study was to evaluate the impact during temperature-controlled radiofrequency ablation of three basic factors regarding electrode-tissue contact and convective cooling on lesion size....

  14. In-vivo continuous monitoring of mixed venous oxygen saturation by photoacoustic transesophageal echocardiography (Conference Presentation)

    Science.gov (United States)

    Li, Li; Subramaniam, Balachundhar; Aguirre, Aaron D.; Andrawes, Michael N.; Tearney, Guillermo J.

    2016-02-01

    Mixed venous oxygen saturation (SvO2), measured from pulmonary arteries, is a gold-standard measure of the dynamic balance between the oxygen supply and demand in the body. In critical care, continuous monitoring of SvO2 plays a vital role in early detection of circulatory shock and guiding goal-oriented resuscitation. In current clinical practice, SvO2 is measured by invasive pulmonary artery catheters (PAC), which are associated with a 10% risk of severe complications. To address the unmet clinical need for a non-invasive SvO2 monitor, we are developing a new technology termed photoacoustic transesophageal echocardiography (PA-TEE). PA-TEE integrates transesophageal echocardiography with photoacoustic oximetry, and enables continuous assessment of SvO2 through an esophageal probe that can be inserted into the body in a minimally invasive manner. We have constructed a clinically translatable PA-TEE prototype, which features a mobile OPO laser, a modified ultrasonography console and a dual-modality esophageal probe. Comprised of a rotatable acoustic array detector, a flexible optical fiber bundle and a light-integrating acoustic lens, the oximetric probe has an outer diameter smaller than 15 mm and will be tolerable for most patients. Through custom-made C++/Qt software, our device acquires and displays ultrasonic and photoacoustic images in real time to guide the deployment of the probe. SvO2 is calculated on-line and updated every second. PA-TEE has now been used to evaluate SvO2 in living swine. Our findings show that changing the fraction of oxygen in the inspired gas modulates SvO2 measured by PA-TEE. Statistic comparison between SvO2 measurements from PA-TEE in vivo the gold-standard laboratorial analysis on blood samples drawn from PACs will be presented.

  15. The advantages of live/real time three-dimensional transesophageal echocardiography during assessments of pulmonary stenosis.

    Science.gov (United States)

    Kemaloğlu Öz, Tuğba; Özpamuk Karadeniz, Fatma; Akyüz, Şükrü; Ünal Dayı, Şennur; Esen Zencirci, Aycan; Atasoy, Işıl; Ösken, Altuğ; Eren, Mehmet

    2016-04-01

    This report sought to compare live/real-time three-dimensional transesophageal echocardiography (3D-TEE) with two-dimensional transesophageal echocardiography (2D-TEE) and to determine whether there are advantages to using 3D-TEE on patients with pulmonary stenosis (PS). Sixteen consecutive adult patients (50 % male and 50 % female; mean age 33 ± 13.4 years) with PS and indications of TEE were prospectively enrolled in this study. Following this, initial 2D-TEE and 3D-TEE examinations were performed, and 3D-TEE images were analyzed using an off-line Q-lab software system. Finally, the 2D-TEE and 3D-TEE findings were compared. In the present study, 3D-TEE allowed us to obtain the en face views of pulmonary valves (PVs) in all but one patient. While this patient was without a PV due to a previous tetralogy of Fallot operation, we could detect the type of PV in the other 15 (93.7 %) patients by using 3D-TEE. Due to poor image quality, the most stenotic area was not measurable in only one (6.2 %) of the patients. In eight (50 %) of the patients, severity and localization of stenosis were more precisely determined with 3DTEE than with 2D-TEE. The PVs' maximal annulus dimensions were found to be significantly larger when they were measured using 3D modalities. This study provides evidence of the incremental value of using 3D-TEE rather than 2D-TEE during assessments of PS, specifically in cases where special conditions (pregnancy, pulmonary regurgitation, and concomitant atrial septal defects) cause recordings of the transvalvular peak gradient to be inaccurate. Therefore, 3D-TEE should be used as a complementary imaging tool to 2D-TEE during routine echocardiographic examinations.

  16. Medline Plus

    Full Text Available ... New York, NY, 1/04/2012) Coronary Artery Disease Transradial Approach for Cardiac Catheterization: The New Frontier ... Medical Center, Chicago, IL, 6/26/2014) Heart Diseases Transesophageal Echocardiogram (TEE) (Shawnee Mission Medical Center, Merriam, ...

  17. Medline Plus

    Full Text Available ... to disable it to view the programs. Blood, Heart and Circulation Angioplasty Transradial Approach for Cardiac Catheterization: ... Chicago Medical Center, Chicago, IL, 6/26/2014) Heart Diseases Transesophageal Echocardiogram (TEE) (Shawnee Mission Medical Center, ...

  18. Perioral Rejuvenation With Ablative Erbium Resurfacing.

    Science.gov (United States)

    Cohen, Joel L

    2015-11-01

    Since the introduction of the scanning full-field erbium laser, misconceptions regarding ablative erbium resurfacing have resulted in its being largely overshadowed by ablative fractional resurfacing. This case report illustrates the appropriateness of full-field erbium ablation for perioral resurfacing. A patient with profoundly severe perioral photodamage etched-in lines underwent full-field ablative perioral resurfacing with an erbium laser (Contour TRL, Sciton Inc., Palo Alto, CA) that allows separate control of ablation and coagulation. The pre-procedure consultations included evaluation of the severity of etched-in lines, and discussion of patient goals, expectations, and appropriate treatment options, as well as a review of patient photos and post-treatment care required. The author generally avoids full-field erbium ablation in patients with Fitzpatrick type IV and above. For each of 2 treatment sessions (separated by approximately 4 months), the patient received (12 cc plain 2% lidodaine) sulcus blocks before undergoing 4 passes with the erbium laser at 150 μ ablation, no coagulation, and then some very focal 30 μ ablation to areas of residual lines still visualized through the pinpoint bleeding. Similarly, full-field ablative resurfacing can be very reliable for significant wrinkles and creping in the lower eyelid skin--where often a single treatment of 80 μ ablation, 50 μ coagulation can lead to a nice improvement. Standardized digital imaging revealed significant improvement in deeply etched rhytides without significant adverse events. For appropriately selected patients requiring perioral (or periorbital) rejuvenation, full-field ablative erbium resurfacing is safe, efficacious and merits consideration.

  19. Uncertainty and variability in computational and mathematical models of cardiac physiology.

    Science.gov (United States)

    Mirams, Gary R; Pathmanathan, Pras; Gray, Richard A; Challenor, Peter; Clayton, Richard H

    2016-12-01

    Mathematical and computational models of cardiac physiology have been an integral component of cardiac electrophysiology since its inception, and are collectively known as the Cardiac Physiome. We identify and classify the numerous sources of variability and uncertainty in model formulation, parameters and other inputs that arise from both natural variation in experimental data and lack of knowledge. The impact of uncertainty on the outputs of Cardiac Physiome models is not well understood, and this limits their utility as clinical tools. We argue that incorporating variability and uncertainty should be a high priority for the future of the Cardiac Physiome. We suggest investigating the adoption of approaches developed in other areas of science and engineering while recognising unique challenges for the Cardiac Physiome; it is likely that novel methods will be necessary that require engagement with the mathematics and statistics community. The Cardiac Physiome effort is one of the most mature and successful applications of mathematical and computational modelling for describing and advancing the understanding of physiology. After five decades of development, physiological cardiac models are poised to realise the promise of translational research via clinical applications such as drug development and patient-specific approaches as well as ablation, cardiac resynchronisation and contractility modulation therapies. For models to be included as a vital component of the decision process in safety-critical applications, rigorous assessment of model credibility will be required. This White Paper describes one aspect of this process by identifying and classifying sources of variability and uncertainty in models as well as their implications for the application and development of cardiac models. We stress the need to understand and quantify the sources of variability and uncertainty in model inputs, and the impact of model structure and complexity and their consequences for

  20. Zero-fluoroscopy cryothermal ablation of atrioventricular nodal re-entry tachycardia guided by endovascular and endocardial catheter visualization using intracardiac echocardiography (Ice&ICE Trial).

    Science.gov (United States)

    Luani, Blerim; Zrenner, Bernhard; Basho, Maksim; Genz, Conrad; Rauwolf, Thomas; Tanev, Ivan; Schmeisser, Alexander; Braun-Dullaeus, Rüdiger C

    2018-01-01

    Stochastic damage of the ionizing radiation to both patients and medical staff is a drawback of fluoroscopic guidance during catheter ablation of cardiac arrhythmias. Therefore, emerging zero-fluoroscopy catheter-guidance techniques are of great interest. We investigated, in a prospective pilot study, the feasibility and safety of the cryothermal (CA) slow-pathway ablation in patients with symptomatic atrioventricular-nodal-re-entry-tachycardia (AVNRT) using solely intracardiac echocardiography (ICE) for endovascular and endocardial catheter visualization. Twenty-five consecutive patients (mean age 55.6 ± 12.0 years, 17 female) with ECG-documentation or symptoms suggesting AVNRT underwent an electrophysiology study (EPS) in our laboratory utilizing ICE for catheter navigation. Supraventricular tachycardia was inducible in 23 (92%) patients; AVNRT was confirmed by appropriate stimulation maneuvers in 20 (80%) patients. All EPS in the AVNRT subgroup could be accomplished without need for fluoroscopy, relying solely on ICE-guidance. CA guided by anatomical location and slow-pathway potentials was successful in all patients, median cryo-mappings = 6 (IQR:3-10), median cryo-ablations = 2 (IQR:1-3). Fluoroscopy was used to facilitate the trans-septal puncture and localization of the ablation substrate in the remaining 3 patients (one focal atrial tachycardia and two atrioventricular-re-entry-tachycardias). Mean EPS duration in the AVNRT subgroup was 99.8 ± 39.6 minutes, ICE guided catheter placement 11.9 ± 5.8 minutes, time needed for diagnostic evaluation 27.1 ± 10.8 minutes, and cryo-application duration 26.3 ± 30.8 minutes. ICE-guided zero-fluoroscopy CA in AVNRT patients is feasible and safe. Real-time visualization of the true endovascular borders and cardiac structures allow for safe catheter navigation during the ICE-guided EPS and might be an alternative to visualization technologies using geometry reconstructions. © 2017 Wiley Periodicals, Inc.

  1. CT-guided Bipolar and Multipolar Radiofrequency Ablation (RF Ablation) of Renal Cell Carcinoma: Specific Technical Aspects and Clinical Results

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de [University Hospital Heidelberg, INF 110, Department of Diagnostic and Interventional Radiology (Germany); Lemm, G.; Hohenstein, E. [Minimally Invasive Therapies and Nuclear Medicine, SLK Kliniken Heilbronn GmbH, Clinic for Radiology (Germany); Bellemann, N.; Stampfl, U. [University Hospital Heidelberg, INF 110, Department of Diagnostic and Interventional Radiology (Germany); Goezen, A. S.; Rassweiler, J. [Clinic for Urology, SLK Kliniken Heilbronn GmbH (Germany); Kauczor, H. U.; Radeleff, B. A. [University Hospital Heidelberg, INF 110, Department of Diagnostic and Interventional Radiology (Germany); Pereira, P. L. [Minimally Invasive Therapies and Nuclear Medicine, SLK Kliniken Heilbronn GmbH, Clinic for Radiology (Germany)

    2013-06-15

    Purpose. This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. Methods. We included 22 consecutive patients (3 women; age 74.2 {+-} 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 {+-} 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Results. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 {+-} 13.6 min and 43.7 {+-} 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 {+-} 8.8 months, local recurrence-free survival was 14.4 {+-} 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 {+-} 16.6 ml/min/1.73 m{sup 2} before RF ablation vs. 47.2 {+-} 11.9 ml/min/1.73 m{sup 2} after RF ablation; not significant). Conclusions. CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.

  2. Intraoperative Two- and Three-Dimensional Transesophageal Echocardiography in Combined Myectomy-Mitral Operations for Hypertrophic Cardiomyopathy.

    Science.gov (United States)

    Nampiaparampil, Robert G; Swistel, Daniel G; Schlame, Michael; Saric, Muhamed; Sherrid, Mark V

    2018-03-01

    Transesophageal echocardiography is essential in guiding the surgical approach for patients with obstructive hypertrophic cardiomyopathy. Septal hypertrophy, elongated mitral valve leaflets, and abnormalities of the subvalvular apparatus are prominent features, all of which may contribute to left ventricular outflow tract obstruction. Surgery aims to alleviate the obstruction via an extended myectomy, often with an intervention on the mitral valve and subvalvular apparatus. The goal of intraoperative echocardiography is to assess the anatomic pathology and pathophysiology in order to achieve a safe intraoperative course and a successful repair. This guide summarizes the systematic evaluation of these patients to determine the best surgical plan. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  3. Water spray assisted ultrashort laser pulse ablation

    International Nuclear Information System (INIS)

    Silvennoinen, M.; Kaakkunen, J.J.J.; Paivasaari, K.; Vahimaa, P.

    2013-01-01

    Highlights: ► We show the novel method to use multibeam processing with ultrashort pulses efficiently. ► Sprayed thin water layer on ablation zone enhances ablation rate and quality. ► In some cases this method also enables ablation of the deeper and straighter holes compared to ones made without the water layer. ► Method also makes possible to directly write features without the self-organizing structures. - Abstract: We have studied femtosecond ablation under sprayed thin water film and its influence and benefits compared with ablation in the air atmosphere. These have been studied in case of the hole and the groove ablation using IR femtosecond laser. Water enhances the ablation rate and in some situations it makes possible to ablate the holes with a higher aspect ratio. While ablating the grooves, the water spray allows using the high fluences without the generation of the self-organized structures.

  4. The effect of ethanol infusion on the size of the ablated lesion in radiofrequency thermal ablation: A pilot study

    International Nuclear Information System (INIS)

    Kim, Young Sun; Rhim, Hyun Chul; Koh, Byung Hee; Cho, On Koo; Seo, Heung Suk; Kim, Yong Soo; Joo, Kyoung Bin

    2001-01-01

    To assess the effect of ethanol infusion on the size of ablated lesion during radiofrequency (RF) thermal ablation. We performed an ex vivo experimental study using a total of 15 pig livers. Three groups were designed: 1)normal control (n=10), 2) saline infusion (n=10) 3) ethanol infusion (n=10). Two radiofrequency ablations were done using a 50 watt RF generator and a 15 guage expandable elections with four prongs in each liver. During ablation for 8 minutes, continuous infusion of fluid at a rate of 0.5 ml/min through the side arm of electrode was performed. We checked the frequency of the 'impeded-out' phenomenon due to abrupt increase of impedance during ablation. Size of ablated lesion was measured according to length, width, height, and subsequently volume after the ablations. The sizes of the ablated lesions were compared between the three groups. 'Impeded-out' phenomenon during ablation was noted 4 times in control group, although that never happened in saline or ethanol infusion groups. There were significant differences in the volumes of ablated lesions between control group (10.62 ± 1.45 cm 3 ) and saline infusion group (15.33 ± 2.47 cm 3 ), and saline infusion group and ethanol infusion group (18.78 ± 3.58 cm 3 ) (p<0.05). Fluid infusion during radiofrequency thermal ablation decrease a chance of charming and increase the volume of the ablated lesion. Ethanol infusion during ablation may induce larger volume of ablated lesion than saline infusion.

  5. Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

    International Nuclear Information System (INIS)

    Ma Yingliang; Housden, R. James; Razavi, Reza; Rhode, Kawal S.; Gogin, Nicolas; Cathier, Pascal; Gijsbers, Geert; Cooklin, Michael; O'Neill, Mark; Gill, Jaswinder; Rinaldi, C. Aldo

    2013-01-01

    Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 ± 0.29, 0.92 ± 0.61, and 0.63 ± 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 ± 0.28, 0.64 ± 0.37, and 0.53 ± 0.38 mm and success rates increased to 100%, 99.2%, and 96

  6. Ablation of Solid Hydrogen in a Plasma

    DEFF Research Database (Denmark)

    Jørgensen, L. W.; Sillesen, Alfred Hegaard

    1979-01-01

    Several hydrogen pellet ablation models based on the formation of a shielding neutral cloud have been reported by different authors. The predicted ablation rates are shown to follow almost the same scaling law and this is used to explain the authors' ablation experiment.......Several hydrogen pellet ablation models based on the formation of a shielding neutral cloud have been reported by different authors. The predicted ablation rates are shown to follow almost the same scaling law and this is used to explain the authors' ablation experiment....

  7. CT-guided Bipolar and Multipolar Radiofrequency Ablation (RF Ablation) of Renal Cell Carcinoma: Specific Technical Aspects and Clinical Results

    International Nuclear Information System (INIS)

    Sommer, C. M.; Lemm, G.; Hohenstein, E.; Bellemann, N.; Stampfl, U.; Goezen, A. S.; Rassweiler, J.; Kauczor, H. U.; Radeleff, B. A.; Pereira, P. L.

    2013-01-01

    Purpose. This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. Methods. We included 22 consecutive patients (3 women; age 74.2 ± 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 ± 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Results. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 ± 13.6 min and 43.7 ± 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 ± 8.8 months, local recurrence-free survival was 14.4 ± 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 ± 16.6 ml/min/1.73 m 2 before RF ablation vs. 47.2 ± 11.9 ml/min/1.73 m 2 after RF ablation; not significant). Conclusions. CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.

  8. Influence of ablation wavelength and time on optical properties of laser ablated carbon dots

    Science.gov (United States)

    Isnaeni, Hanna, M. Yusrul; Pambudi, A. A.; Murdaka, F. H.

    2017-01-01

    Carbon dots, which are unique and applicable materials, have been produced using many techniques. In this work, we have fabricated carbon dots made of coconut fiber using laser ablation technique. The purpose of this work is to evaluate two ablation parameters, which are ablation wavelength and ablation time. We used pulsed laser from Nd:YAG laser with emit wavelength at 355 nm, 532 nm and 1064 nm. We varied ablation time one hour and two hours. Photoluminescence and time-resolved photoluminescence setup were used to study the optical properties of fabricated carbon dots. In general, fabricated carbon dots emit bluish green color emission upon excitation by blue laser. We found that carbon dots fabricated using 1064 nm laser produced the highest carbon dots emission among other samples. The peak wavelength of carbon dots emission is between 495 nm until 505 nm, which gives bluish green color emission. Two hours fabricated carbon dots gave four times higher emission than one hour fabricated carbon dot. More emission intensity of carbon dots means more carbon dots nanoparticles were fabricated during laser ablation process. In addition, we also measured electron dynamics of carbon dots using time-resolved photoluminescence. We found that sample with higher emission has longer electron decay time. Our finding gives optimum condition of carbon dots fabrication from coconut fiber using laser ablation technique. Moreover, fabricated carbon dots are non-toxic nanoparticles that can be applied for health, bio-tagging and medical applications.

  9. In vivo comparison of simultaneous versus sequential injection technique for thermochemical ablation in a porcine model.

    Science.gov (United States)

    Cressman, Erik N K; Shenoi, Mithun M; Edelman, Theresa L; Geeslin, Matthew G; Hennings, Leah J; Zhang, Yan; Iaizzo, Paul A; Bischof, John C

    2012-01-01

    To investigate simultaneous and sequential injection thermochemical ablation in a porcine model, and compare them to sham and acid-only ablation. This IACUC-approved study involved 11 pigs in an acute setting. Ultrasound was used to guide placement of a thermocouple probe and coaxial device designed for thermochemical ablation. Solutions of 10 M acetic acid and NaOH were used in the study. Four injections per pig were performed in identical order at a total rate of 4 mL/min: saline sham, simultaneous, sequential, and acid only. Volume and sphericity of zones of coagulation were measured. Fixed specimens were examined by H&E stain. Average coagulation volumes were 11.2 mL (simultaneous), 19.0 mL (sequential) and 4.4 mL (acid). The highest temperature, 81.3°C, was obtained with simultaneous injection. Average temperatures were 61.1°C (simultaneous), 47.7°C (sequential) and 39.5°C (acid only). Sphericity coefficients (0.83-0.89) had no statistically significant difference among conditions. Thermochemical ablation produced substantial volumes of coagulated tissues relative to the amounts of reagents injected, considerably greater than acid alone in either technique employed. The largest volumes were obtained with sequential injection, yet this came at a price in one case of cardiac arrest. Simultaneous injection yielded the highest recorded temperatures and may be tolerated as well as or better than acid injection alone. Although this pilot study did not show a clear advantage for either sequential or simultaneous methods, the results indicate that thermochemical ablation is attractive for further investigation with regard to both safety and efficacy.

  10. PRKAG2 mutation: An easily missed cardiac specific non-lysosomal glycogenosis

    International Nuclear Information System (INIS)

    Aggarwal, Varun; Dobrolet, Nancy; Fishberger, Steven; Zablah, Jenny; Jayakar, Parul; Ammous, Zineb

    2005-01-01

    Mutations in PRKAG2 gene that regulates the γ2 subunit of the adenosine monophosphate (AMP) dependent protein kinase have been associated with the development of atrioventricular (AV) accessory pathways, cardiac hypertrophy, and conduction system abnormalities. These patients can potentially be misdiagnosed as hypertrophic cardiomyopathy (HOCM) and/or Wolf-Parkinson White (WPW) syndrome due to similar clinical phenotype. Early recognition of this disease entity is very important as ablation of suspected accessory pathways is not effective and the natural history of the disease is very different from HOCM and WPW syndrome

  11. Investigation of different liquid media and ablation times on pulsed laser ablation synthesis of aluminum nanoparticles

    International Nuclear Information System (INIS)

    Baladi, Arash; Sarraf Mamoory, Rasoul

    2010-01-01

    Aluminum nanoparticles were synthesized by pulsed laser ablation of Al targets in ethanol, acetone, and ethylene glycol. Transmission Electron Microscope (TEM) and Scanning Electron Microscope (SEM) images, Particle size distribution diagram from Laser Particle Size Analyzer (LPSA), UV-visible absorption spectra, and weight changes of targets were used for the characterization and comparison of products. The experiments demonstrated that ablation efficiency in ethylene glycol is too low, in ethanol is higher, and in acetone is highest. Comparison between ethanol and acetone clarified that acetone medium leads to finer nanoparticles (mean diameter of 30 nm) with narrower size distribution (from 10 to 100 nm). However, thin carbon layer coats some of them, which was not observed in ethanol medium. It was also revealed that higher ablation time resulted in higher ablated mass, but lower ablation rate. Finer nanoparticles, moreover, were synthesized in higher ablation times.

  12. Investigation of different liquid media and ablation times on pulsed laser ablation synthesis of aluminum nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Baladi, Arash [Materials Engineering Department, Tarbiat Modares University, Jalal Al Ahmad, P.O. Box 14115-143, Tehran (Iran, Islamic Republic of); Sarraf Mamoory, Rasoul, E-mail: rsarrafm@modares.ac.ir [Materials Engineering Department, Tarbiat Modares University, Jalal Al Ahmad, P.O. Box 14115-143, Tehran (Iran, Islamic Republic of)

    2010-10-01

    Aluminum nanoparticles were synthesized by pulsed laser ablation of Al targets in ethanol, acetone, and ethylene glycol. Transmission Electron Microscope (TEM) and Scanning Electron Microscope (SEM) images, Particle size distribution diagram from Laser Particle Size Analyzer (LPSA), UV-visible absorption spectra, and weight changes of targets were used for the characterization and comparison of products. The experiments demonstrated that ablation efficiency in ethylene glycol is too low, in ethanol is higher, and in acetone is highest. Comparison between ethanol and acetone clarified that acetone medium leads to finer nanoparticles (mean diameter of 30 nm) with narrower size distribution (from 10 to 100 nm). However, thin carbon layer coats some of them, which was not observed in ethanol medium. It was also revealed that higher ablation time resulted in higher ablated mass, but lower ablation rate. Finer nanoparticles, moreover, were synthesized in higher ablation times.

  13. Percutaneous Renal Tumor Ablation: Radiation Exposure During Cryoablation and Radiofrequency Ablation

    Energy Technology Data Exchange (ETDEWEB)

    McEachen, James C., E-mail: james.mceachen2@gmail.com [Mayo Clinic, Division of Preventive, Occupational, and Aerospace Medicine (United States); Leng, Shuai; Atwell, Thomas D. [Mayo Clinic, Department of Radiology (United States); Tollefson, Matthew K. [Mayo Clinic, Department of Urology (United States); Friese, Jeremy L. [Mayo Clinic, Department of Radiology (United States); Wang, Zhen; Murad, M. Hassan [Mayo Clinic, Division of Preventive, Occupational, and Aerospace Medicine (United States); Schmit, Grant D. [Mayo Clinic, Department of Radiology (United States)

    2016-02-15

    IntroductionOnce reserved solely for non-surgical cases, percutaneous ablation is becoming an increasingly popular treatment option for a wider array of patients with small renal masses and the radiation risk needs to be better defined as this transition continues.Materials and MethodsRetrospective review of our renal tumor ablation database revealed 425 patients who underwent percutaneous ablation for treatment of 455 renal tumors over a 5-year time period. Imparted radiation dose information was reviewed for each procedure and converted to effective patient dose and skin dose using established techniques. Statistical analysis was performed with each ablative technique.ResultsFor the 331 cryoablation procedures, the mean DLP was 6987 mGycm (SD = 2861) resulting in a mean effective dose of 104.7 mSv (SD = 43.5) and the mean CTDI{sub vol} was 558 mGy (SD = 439) resulting in a mean skin dose of 563.2 mGy (SD = 344.1). For the 124 RFA procedures, the mean DLP was 3485 mGycm (SD = 1630) resulting in a mean effective dose of 50.3 mSv (SD = 24.0) and the mean CTDI{sub vol} was 232 mGy (SD = 149) resulting in a mean skin dose of 233.2 mGy (SD = 117.4). The difference in patient radiation exposure between the two renal ablation techniques was statistically significant (p < 0.001).ConclusionBoth cryoablation and RFA imparted an average skin dose that was well below the 2 Gy deterministic threshold for appreciable sequela. Renal tumor cryoablation resulted in a mean skin and effective radiation dose more than twice that for RFA. The radiation exposure for both renal tumor ablation techniques was at the high end of the medical imaging radiation dose spectrum.

  14. Prosthetic mitral valve obstruction: role of real-time three-dimensional transesophageal echocardiography in diagnosis.

    Science.gov (United States)

    Kannan, Arun; Jahan, Kahroba; Lotun, Kapildeo; Janardhanan, Rajesh

    2015-09-21

    Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode of therapy. We discuss a case of a patient with multiple comorbidities who presented with mechanical mitral valve obstruction where both transthoracic and two-dimensional transesophageal echocardiography (TEE) were limited in making an accurate diagnosis regarding the mechanism of obstruction. Real-time 3D-TEE (RT-3DTEE) was critical in identifying a partial thrombus on the mechanical valve and guided the choice of thrombolysis as the most appropriate intervention, thus avoiding high-risk surgery in this patient with significant multiple comorbidities. 2015 BMJ Publishing Group Ltd.

  15. Dynamic Three-Dimensional Geometry of the Aortic Valve Apparatus-A Feasibility Study

    NARCIS (Netherlands)

    Khamooshian, Arash; Amador, Yannis; Hai, Ting; Jeganathan, Jelliffe; Saraf, Maria; Mahmood, Eitezaz; Matyal, Robina; Khabbaz, Kamal R.; Mariani, Massimo; Mahmood, Feroze

    OBJECTIVE: To provide (1) an overview of the aortic valve (AV) apparatus anatomy and nomenclature, and (2) data regarding the normal AV apparatus geometry and dynamism during the cardiac cycle obtained from three-dimensional transesophageal echocardiography (3D TEE). DESIGN: Retrospective

  16. Left atrial volume assessment in atrial fibrillation using multimodality imaging: a comparison of echocardiography, invasive three-dimensional CARTO and cardiac magnetic resonance imaging.

    Science.gov (United States)

    Rabbat, Mark G; Wilber, David; Thomas, Kevin; Malick, Owais; Bashir, Atif; Agrawal, Anoop; Biswas, Santanu; Sanagala, Thriveni; Syed, Mushabbar A

    2015-06-01

    Left atrial size in atrial fibrillation is a strong predictor of successful ablation and cardiovascular events. Cardiac magnetic resonance multislice method (CMR-MSM) is the current gold standard for left atrial volume (LAV) assessment but is time consuming. We investigated whether LAV with more rapid area-length method by echocardiography (Echo-AL) or cardiac magnetic resonance (CMR-AL) and invasive measurement by 3D-CARTO mapping during ablation correlate with the CMR-MSM. We studied 250 consecutive patients prior to atrial fibrillation ablation. CMR images were acquired on 3T scanner to measure LAV by MSM and biplane area-length method. Standard echocardiography views were used to calculate LAV by biplane area-length method. LAV during ablation was measured by 3D-CARTO mapping. LAV was compared using intra-class correlation (ICC), Pearson's correlation and Bland-Altman plots. CMR-MSM was used as the reference standard. Mean LAV using CMR-MSM was 112.7 ± 36.7 ml. CMR-AL method overestimated LAV by 13.3 ± 21.8 ml (11.2%, p atrial fibrillation. CMR-AL and 3D-CARTO correlated and agreed well with CMR-MSM (r = 0.87 and 0.74, ICC = 0.80 and 0.77 respectively). However, Echo-AL had poor correlation and agreement with CMR-MSM (r = 0.66 and ICC = 0.48). Bland-Altman plots confirmed these findings. CMR-AL method may be used as an alternative to CMR-MSM, as it is non-invasive, rapid, and correlates well with CMR-MSM. LAV by different modalities should not be used interchangeably.

  17. Hydrodynamic instabilities in an ablation front

    International Nuclear Information System (INIS)

    Piriz, A R; Portugues, R F

    2004-01-01

    The hydrodynamic stability of an ablation front is studied for situations in which the wavelength of the perturbations is larger than the distance to the critical surface where the driving radiation is absorbed. An analytical model is presented, and it shows that under conditions in which the thermal flux is limited within the supercritical region of the ablative corona, the front may behave like a flame or like an ablation front, depending on the perturbation wavelength. For relatively long wavelengths the critical and ablation surfaces practically lump together into a unique surface and the front behaves like a flame, whereas for the shortest wavelengths the ablation front substructure is resolved

  18. Hydrodynamic instabilities in an ablation front

    Energy Technology Data Exchange (ETDEWEB)

    Piriz, A R; Portugues, R F [E.T.S.I. Industriales, Universidad de Castilla-La Mancha, 13071 Ciudad Real (Spain)

    2004-06-01

    The hydrodynamic stability of an ablation front is studied for situations in which the wavelength of the perturbations is larger than the distance to the critical surface where the driving radiation is absorbed. An analytical model is presented, and it shows that under conditions in which the thermal flux is limited within the supercritical region of the ablative corona, the front may behave like a flame or like an ablation front, depending on the perturbation wavelength. For relatively long wavelengths the critical and ablation surfaces practically lump together into a unique surface and the front behaves like a flame, whereas for the shortest wavelengths the ablation front substructure is resolved.

  19. Real-time three-dimensional transesophageal echocardiography in the assessment of mechanical prosthetic mitral valve ring thrombosis.

    Science.gov (United States)

    Ozkan, Mehmet; Gürsoy, Ozan Mustafa; Astarcıoğlu, Mehmet Ali; Gündüz, Sabahattin; Cakal, Beytullah; Karakoyun, Süleyman; Kalçık, Macit; Kahveci, Gökhan; Duran, Nilüfer Ekşi; Yıldız, Mustafa; Cevik, Cihan

    2013-10-01

    Although 2-dimensional (2D) transesophageal echocardiography (TEE) is the gold standard for the diagnosis of prosthetic valve thrombosis, nonobstructive clots located on mitral valve rings can be missed. Real-time 3-dimensional (3D) TEE has incremental value in the visualization of mitral prosthesis. The aim of this study was to investigate the utility of real-time 3D TEE in the diagnosis of mitral prosthetic ring thrombosis. The clinical outcomes of these patients in relation to real-time 3D transesophageal echocardiographic findings were analyzed. Of 1,263 patients who underwent echocardiographic studies, 174 patients (37 men, 137 women) with mitral ring thrombosis detected by real-time 3D TEE constituted the main study population. Patients were followed prospectively on oral anticoagulation for 25 ± 7 months. Eighty-nine patients (51%) had thrombi that were missed on 2D TEE and depicted only on real-time 3D TEE. The remaining cases were partially visualized with 2D TEE but completely visualized with real-time 3D TEE. Thirty-seven patients (21%) had thromboembolism. The mean thickness of the ring thrombosis in patients with thromboembolism was greater than that in patients without thromboembolism (3.8 ± 0.9 vs 2.8 ± 0.7 mm, p 3D TEE during follow-up. There were no thrombi in 39 patients (25%); 45 (29%) had regression of thrombi, and there was no change in thrombus size in 68 patients (44%). Thrombus size increased in 3 patients (2%). Thrombosis was confirmed surgically and histopathologically in 12 patients (7%). In conclusion, real-time 3D TEE can detect prosthetic mitral ring thrombosis that could be missed on 2D TEE and cause thromboembolic events. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Effects of renal denervation with a standard irrigated cardiac ablation catheter on blood pressure and renal function in patients with chronic kidney disease and resistant hypertension.

    Science.gov (United States)

    Kiuchi, Márcio Galindo; Maia, George Luiz Marques; de Queiroz Carreira, Maria Angela Magalhães; Kiuchi, Tetsuaki; Chen, Shaojie; Andrea, Bruno Rustum; Graciano, Miguel Luis; Lugon, Jocemir Ronaldo

    2013-07-01

    Evaluation of the safety and efficacy of renal denervation with a standard irrigated cardiac ablation catheter (SICAC) in chronic kidney disease (CKD) patients with refractory hypertension. Twenty-four patients were included and treated with a SICAC. Denervation was performed by a single operator following the standard technique. Patients included with CKD were on stages 2 (n = 16), 3 (n = 4), and 4 (n = 4). Data were obtained at baseline and monthly until 180th day of follow-up. Baseline values of blood pressure (mean ± SD) were 186 ± 19 mmHg/108 ± 13 mmHg in the office, and 151 ± 18 mmHg/92 ± 11 mmHg by 24 h ambulatory blood pressure monitoring (ABPM). Office blood pressure values at 180th day after the procedure were 135 ± 13 mmHg/88 ± 7 mmHg (P < 0.0001, for both comparisons). The mean ABPM decreased to 132 ± 15 mmHg/85 ± 11 mmHg at the 180th day after the procedure (P < 0.0001 for systolic and P = 0.0015 for diastolic). Estimated glomerular filtration (mean ± SD) increased from baseline (64.4 ± 23.9 mL/min/1.73 m(2)) to the 180th day (85.4 ± 34.9 mL/min/1.73 m(2), P < 0.0001) of follow-up. The median urine albumin:creatinine ratio decreased from baseline (48.5, IQR: 35.8-157.2 mg/g) to the 180th day after ablation (ACR = 15.7, IQR: 10.3-34.2 mg/g, P = 0.0017). No major complications were seen. The procedure using SICAC seemed to be feasible, effective, and safe resulting in a better control of BP, a short-term increase in estimated glomerular filtration rate, and reduced albuminuria. Although encouraging, our data are preliminary and need to be validated in the long term.

  1. Efficacy and safety of ablation for people with non-paroxysmal atrial fibrillation.

    Science.gov (United States)

    Nyong, Jonathan; Amit, Guy; Adler, Alma J; Owolabi, Onikepe O; Perel, Pablo; Prieto-Merino, David; Lambiase, Pier; Casas, Juan Pablo; Morillo, Carlos A

    2016-11-22

    The optimal rhythm management strategy for people with non-paroxysmal (persistent or long-standing persistent) atrial fibrilation is currently not well defined. Antiarrhythmic drugs have been the mainstay of therapy. But recently, in people who have not responded to antiarrhythmic drugs, the use of ablation (catheter and surgical) has emerged as an alternative to maintain sinus rhythm to avoid long-term atrial fibrillation complications. However, evidence from randomised trials about the efficacy and safety of ablation in non-paroxysmal atrial fibrillation is limited. To determine the efficacy and safety of ablation (catheter and surgical) in people with non-paroxysmal (persistent or long-standing persistent) atrial fibrillation compared to antiarrhythmic drugs. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE Ovid, Embase Ovid, conference abstracts, clinical trial registries, and Health Technology Assessment Database. We searched these databases from their inception to 1 April 2016. We used no language restrictions. We included randomised trials evaluating the effect of radiofrequency catheter ablation (RFCA) or surgical ablation compared with antiarrhythmic drugs in adults with non-paroxysmal atrial fibrillation, regardless of any concomitant underlying heart disease, with at least 12 months of follow-up. Two review authors independently selected studies and extracted data. We evaluated risk of bias using the Cochrane 'Risk of bias' tool. We calculated risk ratios (RRs) for dichotomous data with 95% confidence intervals (CIs) a using fixed-effect model when heterogeneity was low (I² 40%). Using the GRADE approach, we evaluated the quality of the evidence and used the GRADE profiler (GRADEpro) to import data from Review Manager 5 to create 'Summary of findings' tables. We included three randomised trials with 261 participants (mean age: 60 years) comparing RFCA (159 participants) to antiarrhythmic drugs (102) for non

  2. [Radiofrequency ablation of hepatocellular carcinoma].

    Science.gov (United States)

    Widmann, Gerlig; Schullian, Peter; Bale, Reto

    2013-03-01

    Percutaneous radiofrequency ablation (RFA) is well established in the treatment of hepatocellular carcinoma (HCC). Due to its curative potential, it is the method of choice for non resectable BCLC (Barcelona Liver Clinic) 0 and A. RFA challenges surgical resection for small HCC and is the method of choice in bridging for transplantation and recurrence after resection or transplantation. The technical feasibility of RFA depends on the size and location of the HCC and the availability of ablation techniques (one needle techniques, multi-needle techniques). More recently, stereotactic multi-needle techniques with 3D trajectory planning and guided needle placement substantially improve the spectrum of treatable lesions including large volume tumors. Treatment success depends on the realization of ablations with large intentional margins of tumor free tissue (A0 ablation in analogy to R0 resection), which has to be documented by fusion of post- with pre-ablation images, and confirmed during follow-up imaging.

  3. Incremental benefit of three-dimensional transesophageal echocardiography in the assessment of left main coronary artery stent protrusion.

    Science.gov (United States)

    Arisha, Mohammed J; Hsiung, Ming C; Ahmad, Amier; Nanda, Navin C; Elkaryoni, Ahmed; Mohamed, Ahmed H; Yin, Wei-Hsian

    2017-06-01

    Ostial lesions represent a challenging clinical scenario and percutaneous intervention (PCI) of left main coronary artery ostial lesions has been associated with postintervention complications, including protrusion of deployed stents into a sinus of Valsalva or aortic root. We report a case of stent protrusion into the aortic root following aorto-ostial left main coronary artery PCI, in which three-dimensional transesophageal echocardiography (3DTEE) provided incremental benefit over standard two-dimensional images. Specifically, 3DTEE confirmed the presence of stent protrusion by allowing clear visualization of the stent scaffold, in addition to characterizing the relationship between the stent and surrounding structures. © 2017, Wiley Periodicals, Inc.

  4. A spectral analysis of ablating meteors

    Science.gov (United States)

    Bloxam, K.; Campbell-Brown, M.

    2017-09-01

    Meteor ablation features in the spectral lines occurring at 394, 436, 520, and 589 nm were observed using a four-camera spectral system between September and December 2015. In conjunction with this multi-camera system the Canadian Automated Meteor Observatory was used to observe the orbital parameters and fragmentation of these meteors. In total, 95 light curves with complete data in the 520 and 589 nm filters were analyzed; some also had partial or complete data in the 394 nm filter, but no usable data was collected with the 436 nm filter. Of the 95 events, 70 exhibited some degree of differential ablation, and in all except 3 of these 70 events the 589 nm filter started or ended sooner compared with the 520 nm filter, indicating early ablation at the 589 nm wavelength. In the majority of cases the meteor showed evidence of fragmentation regardless of the type of ablation (differential or uniform). A surprising result was the lack of correlation found concerning the KB parameter, linked to meteoroid strength, and differential ablation. In addition, 22 shower-associated meteors were observed; Geminids showed mainly slight differential ablation, while Taurids were more likely to ablate uniformly.

  5. Aorto-right atrial fistula after Bentall repair

    OpenAIRE

    Howard, Charles E.; Velasco, Carlos E.; Roullard, Christina P.; Rafael, Aldo

    2017-01-01

    We describe a man with the Marfan syndrome and a prior ascending aortic aneurysm resection who presented with knee pain and concern of endocarditis. Transesophageal echocardiogram showed no vegetations, and computed tomography angiogram of the heart showed a possible pseudoaneurysm. Cardiac catheterization and aortogram revealed the diagnosis of an aorto-right atrial fistula, which was then operatively repaired. This case highlights the role that cardiac catheterization with aortogram can pla...

  6. WE-EF-BRA-03: Catheter- Free Ablation with External Photon Radiation: Treatment Planning, Delivery Considerations, and Correlation of Effects with Delivered Dose

    International Nuclear Information System (INIS)

    Deisher, A; Anderson, S; Cusma, J; Herman, M; Johnson, S; Lehmann, H; Packer, D; Parker, K; Song, L; Takami, M; Kruse, J

    2015-01-01

    Purpose: To plan, target, and calculate delivered dose in atrioventricular node (AVN) ablation with volume-modulated arc therapy (VMAT) in an intact porcine model. Methods: Seven pigs underwent AVN irradiation, with prescription doses ranging between 25 and 55Gy in a single fraction. Cardiac CT scans were acquired at expiration. Two physicians contoured AVN targets on 10 phases, providing estimates of target motion and inter-physician variability. Treatment planning was conducted on a static phase-averaged CT. The volume designated to receive prescription dose covered the full extent of AVN cardiac motion, expanded by 4mm for setup uncertainty. Optimization limited doses to risk structures according to single-fraction tumor treatment protocols. Orthogonal kV images were used to align bony anatomy at time of treatment. Localization was further refined with respiratory-gated cone-beam CT, and range of cardiac motion was verified under fluoroscopy. Beam delivery was respiratory-gated for expiration with a mean efficiency of 60%. Deformable registration of the 10 cardiac CT phases was used to calculate actual delivered dose for comparison to electro-anatomical and visually evident lesions. Results: The mean [minimum,maximum] amplitude of AVN cardiac motion was LR 2.9 [1.7,3.9]mm, AP 6.6 [4.4,10.4]mm, and SI 5.6 [2.0,9.9]mm. Incorporating cardiac motion into the dose calculation showed the volume receiving full dose was 40–80% of the volume indicated on the static planning image, although the contoured AVN target received full dose in all animals. Initial results suggest the dimensions of the electro-anatomical lesion are correlated with the 40Gy isodose volume. Conclusion: Image-guidance techniques allow for accurate and precise delivery of VMAT for catheter-free arrhythmia ablation. An arsenal of advanced radiation planning, dose optimization, and image-guided delivery techniques was employed to assess and mitigate effects of cardiac and respiratory motion

  7. WE-EF-BRA-03: Catheter- Free Ablation with External Photon Radiation: Treatment Planning, Delivery Considerations, and Correlation of Effects with Delivered Dose

    Energy Technology Data Exchange (ETDEWEB)

    Deisher, A; Anderson, S; Cusma, J; Herman, M; Johnson, S; Lehmann, H; Packer, D; Parker, K; Song, L; Takami, M; Kruse, J [Mayo Clinic, Rochester, MN (United States)

    2015-06-15

    Purpose: To plan, target, and calculate delivered dose in atrioventricular node (AVN) ablation with volume-modulated arc therapy (VMAT) in an intact porcine model. Methods: Seven pigs underwent AVN irradiation, with prescription doses ranging between 25 and 55Gy in a single fraction. Cardiac CT scans were acquired at expiration. Two physicians contoured AVN targets on 10 phases, providing estimates of target motion and inter-physician variability. Treatment planning was conducted on a static phase-averaged CT. The volume designated to receive prescription dose covered the full extent of AVN cardiac motion, expanded by 4mm for setup uncertainty. Optimization limited doses to risk structures according to single-fraction tumor treatment protocols. Orthogonal kV images were used to align bony anatomy at time of treatment. Localization was further refined with respiratory-gated cone-beam CT, and range of cardiac motion was verified under fluoroscopy. Beam delivery was respiratory-gated for expiration with a mean efficiency of 60%. Deformable registration of the 10 cardiac CT phases was used to calculate actual delivered dose for comparison to electro-anatomical and visually evident lesions. Results: The mean [minimum,maximum] amplitude of AVN cardiac motion was LR 2.9 [1.7,3.9]mm, AP 6.6 [4.4,10.4]mm, and SI 5.6 [2.0,9.9]mm. Incorporating cardiac motion into the dose calculation showed the volume receiving full dose was 40–80% of the volume indicated on the static planning image, although the contoured AVN target received full dose in all animals. Initial results suggest the dimensions of the electro-anatomical lesion are correlated with the 40Gy isodose volume. Conclusion: Image-guidance techniques allow for accurate and precise delivery of VMAT for catheter-free arrhythmia ablation. An arsenal of advanced radiation planning, dose optimization, and image-guided delivery techniques was employed to assess and mitigate effects of cardiac and respiratory motion

  8. Acute Cor Pulmonale and Right Heat Failure Complicating Ethanol Ablative Therapy: Anesthetic and Radiologic Considerations and Management

    Energy Technology Data Exchange (ETDEWEB)

    Naik, Bhiken, E-mail: bin4n@virginia.edu [University of Virginia, Department of Anesthesiology (United States); Matsumoto, Alan H. [University of Virginia, Department of Radiology and Medical Imaging (United States)

    2013-10-15

    Ethanol is an effective ablative agent used for the treatment of certain solid organ tumors and vascular malformations (VMs). The egress of ethanol beyond the target tissue can be associated with significant changes to the cardiopulmonary system that can lead to cardiac arrest. This article reviews the contemporary role of ethanol in tumor and VM treatment and discusses the physiological mechanisms of acute pulmonary hypertension and cardiovascular collapse. The importance of periprocedural recognition of the hemodynamic changes that can occur with the use of ethanol and the treatment of this condition are discussed.

  9. CT-guided radiofrequency tumor ablation in children

    International Nuclear Information System (INIS)

    Botsa, Evanthia; Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas; Koutsogiannis, Ioannis; Ziakas, Panayiotis D.; Alexopoulou, Efthimia

    2014-01-01

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  10. CT-guided radiofrequency tumor ablation in children

    Energy Technology Data Exchange (ETDEWEB)

    Botsa, Evanthia [National and Kapodistrian University of Athens, First Pediatric Clinic, Agia Sofia Children' s Hospital, Athens (Greece); Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas [Sotiria General Hospital for Chest Diseases, Department of Medical Imaging and Interventional Radiology, Athens (Greece); Koutsogiannis, Ioannis [General Military Hospital NIMTS, Department of Medical Imaging, Athens (Greece); Ziakas, Panayiotis D. [Warren Alpert Medical School of Brown University Rhode Island Hospital, Division of Infectious Diseases, Providence, RI (United States); Alexopoulou, Efthimia [Attikon University Hospital, Second Department of Radiology, Athens University School of Medicine, Athens (Greece)

    2014-11-15

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  11. Advances in laser ablation of materials

    International Nuclear Information System (INIS)

    Singh, R.K.; Lowndes, D.H.; Chrisey, D.B.; Fogarassy, E.; Narayan, J.

    1998-01-01

    The symposium, Advances in Laser Ablation of Materials, was held at the 1998 MRS Spring Meeting in San Francisco, California. The papers in this symposium illustrate the advances in pulsed laser ablation for a wide variety of applications involving semiconductors, superconductors, metals, ceramics, and polymers. In particular, advances in the deposition of oxides and related materials are featured. Papers dealing with both fundamentals and the applications of laser ablation are presented. Topical areas include: fundamentals of ablation and growth; in situ diagnostics and nanoscale synthesis advances in laser ablation techniques; laser surface processing; pulsed laser deposition of ferroelectric, magnetic, superconducting and optoelectronic thin films; and pulsed laser deposition of carbon-based and polymeric materials. Sixty papers have been processed separately for inclusion on the data base

  12. Efficacy and Safety of Radiofrequency Ablation for Focal Hepatic Lesions Adjacent to Gallbladder: Reconfiguration of the Ablation Zone through Probe Relocation and Ablation Time Reduction.

    Science.gov (United States)

    Choi, In Young; Kim, Pyo Nyun; Lee, Sung Gu; Won, Hyung Jin; Shin, Yong Moon

    2017-10-01

    To evaluate the safety and efficacy of radiofrequency (RF) ablation for treatment of focal hepatic lesions adjacent to the gallbladder with electrode relocation and ablation time reduction. Thirty-nine patients who underwent RF ablation for focal hepatic lesions adjacent to the gallbladder (≤ 10 mm) were evaluated retrospectively from January 2011 to December 2014 (30 men and 9 women; age range, 51-85 y; mean age, 65 y). Of 36 patients with hepatocellular carcinoma, 3 had a second treatment for recurrence (mean tumor size, 15 mm ± 6). Patients were divided into 2 subgroups based on lesion distance from the gallbladder: nonabutting (> 5 mm; n = 19) and abutting (≤ 5 mm; n = 20). Electrodes were inserted parallel to the gallbladder through the center of a tumor in the nonabutting group and through the center of the expected ablation zone between a 5-mm safety zone on the liver side and the gallbladder in the abutting group. Ablation time was decreased in proportion to the transverse diameter of the expected ablation zone. Technical success and technical effectiveness rates were 89.7% and 97.4%, respectively, with no significant differences between groups (P = 1.00). Local tumor progression was observed in 3 patients (1 in the nonabutting group and 2 in the abutting group; P = 1.00). There were no major complications. The gallbladder was thickened in 10 patients, with no significant difference between groups (P = .72). Biloma occurred in 1 patient in the nonabutting group. RF ablation with electrode relocation and reduction of ablation time can be a safe and effective treatment for focal hepatic lesions adjacent to the gallbladder. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  13. Characterization of tracked radiofrequency ablation in phantom

    International Nuclear Information System (INIS)

    Chen, Chun-Cheng R.; Miga, Michael I.; Galloway, Robert L.

    2007-01-01

    In radiofrequency ablation (RFA), successful therapy requires accurate, image-guided placement of the ablation device in a location selected by a predictive treatment plan. Current planning methods rely on geometric models of ablations that are not sensitive to underlying physical processes in RFA. Implementing plans based on computational models of RFA with image-guided techniques, however, has not been well characterized. To study the use of computational models of RFA in planning needle placement, this work compared ablations performed with an optically tracked RFA device with corresponding models of the ablations. The calibration of the tracked device allowed the positions of distal features of the device, particularly the tips of the needle electrodes, to be determined to within 1.4±0.6 mm of uncertainty. Ablations were then performed using the tracked device in a phantom system based on an agarose-albumin mixture. Images of the sliced phantom obtained from the ablation experiments were then compared with the predictions of a bioheat transfer model of RFA, which used the positional data of the tracked device obtained during ablation. The model was demonstrated to predict 90% of imaged pixels classified as being ablated. The discrepancies between model predictions and observations were analyzed and attributed to needle tracking inaccuracy as well as to uncertainties in model parameters. The results suggest the feasibility of using finite element modeling to plan ablations with predictable outcomes when implemented using tracked RFA

  14. Simple spherical ablative-implosion model

    International Nuclear Information System (INIS)

    Mayer, F.J.; Steele, J.T.; Larsen, J.T.

    1980-01-01

    A simple model of the ablative implosion of a high-aspect-ratio (shell radius to shell thickness ratio) spherical shell is described. The model is similar in spirit to Rosenbluth's snowplow model. The scaling of the implosion time was determined in terms of the ablation pressure and the shell parameters such as diameter, wall thickness, and shell density, and compared these to complete hydrodynamic code calculations. The energy transfer efficiency from ablation pressure to shell implosion kinetic energy was examined and found to be very efficient. It may be possible to attach a simple heat-transport calculation to our implosion model to describe the laser-driven ablation-implosion process. The model may be useful for determining other energy driven (e.g., ion beam) implosion scaling

  15. Field enhancement induced laser ablation

    DEFF Research Database (Denmark)

    Fiutowski, Jacek; Maibohm, Christian; Kjelstrup-Hansen, Jakob

    Sub-diffraction spatially resolved, quantitative mapping of strongly localized field intensity enhancement on gold nanostructures via laser ablation of polymer thin films is reported. Illumination using a femtosecond laser scanning microscope excites surface plasmons in the nanostructures....... The accompanying field enhancement substantially lowers the ablation threshold of the polymer film and thus creates local ablation spots and corresponding topographic modifications of the polymer film. Such modifications are quantified straightforwardly via scanning electron and atomic force microscopy. Thickness...

  16. Radiofrequency ablation in dermatology

    Directory of Open Access Journals (Sweden)

    Sachdeva Silonie

    2007-01-01

    Full Text Available Radiofreqeuency ablation is a versatile dermatosurgical procedure used for surgical management of skin lesions by using various forms of alternating current at an ultra high frequency. The major modalities in radiofrequency are electrosection, electrocoagulation, electrodessication and fulguration. The use of radiofrequency ablation in dermatosurgical practice has gained importance in recent years as it can be used to treat most of the skin lesions with ease in less time with clean surgical field due to adequate hemostasis and with minimal side effects and complications. This article focuses on the major tissue effects and factors influencing radiofrequency ablation and its application for various dermatological conditions.

  17. Percutaneous Microwave Ablation of Renal Angiomyolipomas

    Energy Technology Data Exchange (ETDEWEB)

    Cristescu, Mircea, E-mail: mcristescu@uwhealth.org [University of Wisconsin, Department of Radiology (United States); Abel, E. Jason, E-mail: abel@urology.wisc.edu [University of Wisconsin, Department of Urology (United States); Wells, Shane, E-mail: swells@uwhealth.org; Ziemlewicz, Timothy J., E-mail: tziemlewicz@uwhealth.org [University of Wisconsin, Department of Radiology (United States); Hedican, Sean P., E-mail: hedican@surgery.wisc.edu [University of Wisconsin, Department of Urology (United States); Lubner, Megan G., E-mail: mlubner@uwhealth.org; Hinshaw, J. Louis, E-mail: jhinshaw@uwhealth.org; Brace, Christopher L., E-mail: cbrace@uwhealth.org; Lee, Fred T., E-mail: flee@uwhealth.org [University of Wisconsin, Department of Radiology (United States)

    2016-03-15

    PurposeTo evaluate the safety and efficacy of US-guided percutaneous microwave (MW) ablation in the treatment of renal angiomyolipoma (AML).Materials and MethodsFrom January 2011 to April 2014, seven patients (5 females and 2 males; mean age 51.4) with 11 renal AMLs (9 sporadic type and 2 tuberous sclerosis associated) with a mean size of 3.4 ± 0.7 cm (range 2.4–4.9 cm) were treated with high-powered, gas-cooled percutaneous MW ablation under US guidance. Tumoral diameter, volume, and CT/MR enhancement were measured on pre-treatment, immediate post-ablation, and delayed post-ablation imaging. Clinical symptoms and creatinine were assessed on follow-up visits.ResultsAll ablations were technically successful and no major complications were encountered. Mean ablation parameters were ablation power of 65 W (range 60–70 W), using 456 mL of hydrodissection fluid per patient, over 4.7 min (range 3–8 min). Immediate post-ablation imaging demonstrated mean tumor diameter and volume decreases of 1.8 % (3.4–3.3 cm) and 1.7 % (27.5–26.3 cm{sup 3}), respectively. Delayed imaging follow-up obtained at a mean interval of 23.1 months (median 17.6; range 9–47) demonstrated mean tumor diameter and volume decreases of 29 % (3.4–2.4 cm) and 47 % (27.5–12.1 cm{sup 3}), respectively. Tumoral enhancement decreased on immediate post-procedure and delayed imaging by CT/MR parameters, indicating decreased tumor vascularity. No patients required additional intervention and no patients experienced spontaneous bleeding post-ablation.ConclusionOur early experience with high-powered, gas-cooled percutaneous MW ablation demonstrates it to be a safe and effective modality to devascularize and decrease the size of renal AMLs.

  18. The outcome of I-131 ablation therapy for intermediate and high-risk differentiated thyroid cancer using a strict definition of successful ablation.

    Science.gov (United States)

    Watanabe, Ken; Uchiyama, Mayuki; Fukuda, Kunihiko

    2017-09-01

    This article examines the outcome of radioactive iodine ablation therapy for thyroid cancer in high-risk patients and investigates background factors influencing ablation failure. We included 91 patients in this retrospective analysis and evaluated the ablation success rate. Successful ablation was defined as the absence of visible iodine-131 (I-131) accumulation in the thyroid bed after whole-body scans and thyroglobulin levels sex, I-131 dose, pathology, resection stump findings, tumor T category and thyroglobulin levels, which could affect ablation outcome. Successful ablation was achieved in only 14 patients (15.4%). Pre-ablation serum thyroglobulin levels were significantly higher in the ablation failure group than in the success group (P 10 ng/ml were significantly related to ablation failure after multivariate analysis (odds ratio 27.2; 95% confidence interval 2.469-299.7; P = 0.007). The ablation success rate was very low because of high thyroglobulin levels, even with high-dose I-131. High-risk patients, especially those with high thyroglobulin levels (>10 ng/ml), are unlikely to reach levels low enough to meet successful ablation criteria.

  19. Atrial Septal Aneurysm and Patent Foramen Ovale as Risk Factors for Cryptogenic Stroke in Patients Less Than 55 Years of Age: A Study using Transesophageal Echocardiography

    Science.gov (United States)

    Cabanes, L.; Mas, J. L.; Cohen, A.; Amarenco, P.; Cabanes, P. A.; Oubary, P.; Chedru, F.; Guerin, F.; Bousser, M. G.; deRecondo, J.

    1993-01-01

    Background and Purpose: An association between atrial septal aneurysm and embolic events has been suggested. Atrial septal aneurysm has been shown to be associated with patent foramen ovale and,.in some reports, with mitral valve prolapse. These two latter cardiac disorder; have been identified as potential risk factors for ischemic stroke. The aim of this prospective study was to assess the role of atrial septal aneurysm as an independent risk factor for stroke, especially for cryptogenic stroke. Methods: We studied the prevalence of atrial septal aneurysm, patent foramen ovale, and mitral valve prolapse in 100 consecutive patients ischemic stroke who underwent extensive etiological investigations. We compared these results with those in a control group of 50 consecutive patients. The diagnosis of atrial septal aneurysm and patent foramen ovale relied on transesophageal echocardiography with a contrast study and that of mitral valve prolapse, on two-dimensional transthoracic echocardiography. Results: Stepwise logistic regression analysis showed that atrial septal aneurysm (odds ratio, 4.3; 95% confidence interval, 1.3 to 14.6; P=.01) and patent foramen ovale (odds ratio, 3.9; 95% confidence interval, 1.5 to 10; P=.003) but not mitral valve prolapse were significantly associated with the diagnosis of cryptogenic stroke. The stroke odds of a patient with both atrial septal aneurysm and patent foramen ovale were 33.3 times (95% confidence interval, 4.1 to 270) the stroke odds of a patient with neither of these cardiac disorders. For a patient with atrial septal aneurysm of >lo-mm excursion, the stroke odds were approximately 8 times the stroke odds of a patient with atrial septal aneurysm of stroke and that their association has a marked synergistic effect. Atrial septal aneurysms of >lo-mm excursion are associated with a higher risk of stroke. (Stroke. 1993;24:1865-1873.) KEY WORDS aneurysm echocardiography foramen ovale, patent mitral valve prolapse o young adults

  20. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  1. Capturing Pain in the Cortex during General Anesthesia: Near Infrared Spectroscopy Measures in Patients Undergoing Catheter Ablation of Arrhythmias.

    Directory of Open Access Journals (Sweden)

    Barry D Kussman

    Full Text Available The predictability of pain makes surgery an ideal model for the study of pain and the development of strategies for analgesia and reduction of perioperative pain. As functional near-infrared spectroscopy reproduces the known functional magnetic resonance imaging activations in response to a painful stimulus, we evaluated the feasibility of functional near-infrared spectroscopy to measure cortical responses to noxious stimulation during general anesthesia. A multichannel continuous wave near-infrared imager was used to measure somatosensory and frontal cortical activation in patients undergoing catheter ablation of arrhythmias under general anesthesia. Anesthetic technique was standardized and intraoperative NIRS signals recorded continuously with markers placed in the data set for the timing and duration of each cardiac ablation event. Frontal cortical signals only were suitable for analysis in five of eight patients studied (mean age 14 ± 1 years, weight 66.7 ± 17.6 kg, 2 males. Thirty ablative lesions were recorded for the five patients. Radiofrequency or cryoablation was temporally associated with a hemodynamic response function in the frontal cortex characterized by a significant decrease in oxyhemoglobin concentration (paired t-test, p<0.05 with the nadir occurring in the period 4 to 6 seconds after application of the ablative lesion. Cortical signals produced by catheter ablation of arrhythmias in patients under general anesthesia mirrored those seen with noxious stimulation in awake, healthy volunteers, during sedation for colonoscopy, and functional Magnetic Resonance Imaging activations in response to pain. This study demonstrates the feasibility and potential utility of functional near-infrared spectroscopy as an objective measure of cortical activation under general anesthesia.

  2. Micrometeoroid ablation simulated in the laboratory

    Science.gov (United States)

    Sternovsky, Zoltan; Thomas, Evan W.; DeLuca, Michael; Horanyi, Mihaly; Janches, Diego; Munsat, Tobin L.; Plane, John M. C.

    2016-04-01

    A facility is developed to simulate the ablation of micrometeoroids in laboratory conditions, which also allows measuring the ionization probability of the ablated material. An electrostatic dust accelerator is used to generate iron and meteoric analog particles with velocities 10-50 km/s. The particles are then introduced into a cell filled with nitrogen, air or carbon dioxide gas with pressures adjustable in the 0.02 - 0.5 Torr range, where the partial or complete ablation of the particle occurs over a short distance. An array of biased electrodes is used to collect the ionized products with spatial resolution along the ablating particles' path, allowing thus the study of the temporal resolution of the process. A simple ablation model is used to match the observations. For completely ablated particles the total collected charge directly yields the ionization efficiency for. The measurements using iron particles in N2 and air are in relatively good agreement with earlier data. The measurements with CO2 and He gases, however, are significantly different from the expectations.

  3. The outcome of I-131 ablation therapy for intermediate and high-risk differentiated thyroid cancer using a strict definition of successful ablation

    International Nuclear Information System (INIS)

    Watanabe, Ken; Uchiyama, Mayuki; Fukuda, Kunihiko

    2017-01-01

    This article examines the outcome of radioactive iodine ablation therapy for thyroid cancer in nigh-risk patients and investigates background factors influencing ablation failure. We included 91 patients in this retrospective analysis and evaluated the ablation success rate. Successful ablation was defined as the absence of visible iodine-131 (I-131) accumulation in the thyroid bed after whole-body scans and thyroglobulin levels <2 ng/ml in a TSH-stimulated state after ablation. We extracted data on patients' age, sex, I-131 dose, pathology, resection stump findings, tumor T category and thyroglobulin levels, which could affect ablation outcome. Successful ablation was achieved in only 14 patients (15.4%). Pre-ablation serum thyroglobulin levels were significantly higher in the ablation failure group than in the success group (P < 0.001), while no significant differences were found for other factors between the groups. Furthermore, thyroglobulin levels >10 ng/ml were significantly related to ablation failure after multivariate analysis (odds ratio 27.2; 95% confidence interval 2.469-299.7; P = 0.007). The ablation success rate was very low because of high thyroglobulin levels, even with high-dose I-131. High-risk patients, especially those with high thyroglobulin levels (>10 ng/ml), are unlikely to reach levels low enough to meet successful ablation criteria. (author)

  4. Cryoballoon Ablation for Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Jason G. Andrade, MD

    2012-03-01

    Full Text Available Focal point-by-point radiofrequency catheter ablation has shown considerable success in the treatment of paroxysmal atrial fibrillation. However, it is not without limitations. Recent clinical and preclinical studies have demonstrated that cryothermal ablation using a balloon catheter (Artic Front©, Medtronic CryoCath LP provides an effective alternative strategy to treating atrial fibrillation. The objective of this article is to review efficacy and safety data surrounding cryoballoon ablation for paroxysmal and persistent atrial fibrillation. In addition, a practical step-by-step approach to cryoballoon ablation is presented, while highlighting relevant literature regarding: 1 the rationale for adjunctive imaging, 2 selection of an appropriate cryoballoon size, 3 predictors of efficacy, 4 advanced trouble-shooting techniques, and 5 strategies to reduce procedural complications, such as phrenic nerve palsy.

  5. Late infectious endocarditis of surgical patch closure of atrial septal defects diagnosed by 18F-fluorodeoxyglucose gated cardiac computed tomography (18F-FDG-PET/CT): a case report.

    Science.gov (United States)

    Honnorat, Estelle; Seng, Piseth; Riberi, Alberto; Habib, Gilbert; Stein, Andreas

    2016-08-24

    In contrast to percutaneous atrial septal occluder device, surgical patch closure of atrial defects was known to be no infective endocarditis risk. We herein report the first case of late endocarditis of surgical patch closure of atrial septal defects occurred at 47-year after surgery. On September 2014, a 56-year-old immunocompetent French Caucasian man was admitted into the Emergency Department for 3-week history of headache, acute decrease of psychomotor performance and fever at 40 °C. The diagnosis has been evoked during his admission for the management of a brain abscess and confirmed using 18F-fluorodeoxyglucose gated cardiac computed tomography (18F-FDG-PET/CT). Bacterial cultures of surgical deep samples of brain abscess were positive for Streptococcus intermedius and Aggregatibacter aphrophilus as identified by the matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometry and confirmed with 16S rRNA gene sequencing. The patient was treated by antibiotics for 8 weeks and surgical patch closure removal. In summary, late endocarditis on surgical patch and on percutaneous atrial septal occluder device of atrial septal defects is rare. Cardiac imaging by the 18F-fluorodeoxyglucose gated cardiac computed tomography (18F-FDG-PET/CT) could improve the diagnosis and care endocarditis on surgical patch closure of atrial septal defects while transthoracic and transesophageal echocardiography remained difficult to interpret.

  6. Burn, freeze, or photo-ablate?: comparative symptom profile in Barrett's dysplasia patients undergoing endoscopic ablation

    Science.gov (United States)

    Gill, Kanwar Rupinder S.; Gross, Seth A.; Greenwald, Bruce D.; Hemminger, Lois L.; Wolfsen, Herbert C.

    2009-06-01

    Background: There are few data available comparing endoscopic ablation methods for Barrett's esophagus with high-grade dysplasia (BE-HGD). Objective: To determine differences in symptoms and complications associated with endoscopic ablation. Design: Prospective observational study. Setting: Two tertiary care centers in USA. Patients: Consecutive patients with BE-HGD Interventions: In this pilot study, symptoms profile data were collected for BE-HGD patients among 3 endoscopic ablation methods: porfimer sodium photodynamic therapy, radiofrequency ablation and low-pressure liquid nitrogen spray cryotherapy. Main Outcome Measurements: Symptom profiles and complications from the procedures were assessed 1-8 weeks after treatment. Results: Ten BE-HGD patients were treated with each ablation modality (30 patients total; 25 men, median age: 69 years (range 53-81). All procedures were performed in the clinic setting and none required subsequent hospitalization. The most common symptoms among all therapies were chest pain, dysphagia and odynophagia. More patients (n=8) in the porfimer sodium photodynamic therapy group reported weight loss compared to radio-frequency ablactation (n=2) and cryotherapy (n=0). Four patients in the porfimer sodium photodynamic therapy group developed phototoxicity requiring medical treatment. Strictures, each requiring a single dilation, were found in radiofrequency ablactation (n=1) and porfimer sodium photodynamic therapy (n=2) patients. Limitations: Small sample size, non-randomized study. Conclusions: These three endoscopic therapies are associated with different types and severity of post-ablation symptoms and complications.

  7. Radiation exposure to patients and operator during radiofrequency ablation for supraventricular tachycardia

    International Nuclear Information System (INIS)

    Kovoor, P.; Ricciardello, M.; Collins, L.; Uther, J.B.; Ross, D.L.

    1995-01-01

    Radiofrequency (RF) ablation has become the primary method of treatment for supraventricular tachycardia and often requires prolonged fluoroscopy times. The aim of this study was to quantitate radiation exposure to patient and operator during RF ablation for supra- ventricular tachycardia. Thermoluminescent dosemeters were used to monitor radiation at seven sites. Positions were: patient's thyroid, left scapula, T9 vertebra, right scapula and L4-L5 vertebra and the operator's thyroid and left hand. Monitoring was performed during 22 procedures. Of the patients studied 10 (45%) had atrioventricular junctional re-entry tachycardia (AVJRT) and 12 (55%) had accessory pathway tachycardia. The median fluoroscopy times (minutes) and inter-quartile ranges were 46 (39-65) for AVJRT, 55 (52-60) for left free wall accessory pathway (LFW), 107 (89-140) for septal and 166 (128-176) for RFW pathways. The mean radiation doses (mGy) to the chest wall were 50 for AVJRT, 47 for LFW, 87 for septal and 151 for RFW pathways. The mean radiation to the chest wall of the patient per case was found to be 3.9 times that reported for diagnostic cardiac catheterisation and 1.5 times that reported for angioplasty. It is concluded that radiofrequency ablation is associated with significant irradiation of the patient and operator. All precautions should be taken to decrease this exposure. If eye irradiation is assumed to be equal to that to the thyroid, more than 45 procedures per month by a single operator (using ceiling-suspended lead glass shielding) may result in exceeding the recommended dose limit to the eye. 32 refs., 3 tabs

  8. Microwave Ablation of Porcine Kidneys in vivo: Effect of two Different Ablation Modes (“Temperature Control” and “Power Control”) on Procedural Outcome

    International Nuclear Information System (INIS)

    Sommer, C. M.; Arnegger, F.; Koch, V.; Pap, B.; Holzschuh, M.; Bellemann, N.; Gehrig, T.; Senft, J.; Nickel, F.; Mogler, C.; Zelzer, S.; Meinzer, H. P.; Stampfl, U.; Kauczor, H. U.; Radeleff, B. A.

    2012-01-01

    Purpose: This study was designed to analyze the effect of two different ablation modes (“temperature control” and “power control”) of a microwave system on procedural outcome in porcine kidneys in vivo. Methods: A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96°C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96°C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity). Results: System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60 ± 0 s in group I and 102 ± 21 s in group II. Long axis diameter was 20.3 ± 4.6 mm in group I and 19.8 ± 3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3 ± 2 mm in group I and 10.5 ± 2.4 mm in group II (NS). Circularity was 0.5 ± 0.1 in group I and 0.5 ± 0.1 in group II (NS). Conclusions: Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.

  9. Attitudes Towards Catheter Ablation for Atrial Fibrillation

    DEFF Research Database (Denmark)

    Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis

    2015-01-01

    BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians´ attitudes towards catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish...... cardiologists towards catheter ablation for AF, using a nationwide survey. METHODS AND RESULTS: We developed a purpose-designed questionnaire to evaluate attitudes towards catheter ablation for AF that was sent to all Danish cardiologists (n = 401; response n = 272 (67.8%)). There was no association between...... attitudes towards ablation and the experience or age of the cardiologist with respect to patients with recurrent AF episodes with a duration of 7 days and/or need for cardioversion. The majority (69%) expected a recurrence of AF after catheter ablation in more than 30% of the cases...

  10. Identification of cardiac rhythm features by mathematical analysis of vector fields.

    Science.gov (United States)

    Fitzgerald, Tamara N; Brooks, Dana H; Triedman, John K

    2005-01-01

    Automated techniques for locating cardiac arrhythmia features are limited, and cardiologists generally rely on isochronal maps to infer patterns in the cardiac activation sequence during an ablation procedure. Velocity vector mapping has been proposed as an alternative method to study cardiac activation in both clinical and research environments. In addition to the visual cues that vector maps can provide, vector fields can be analyzed using mathematical operators such as the divergence and curl. In the current study, conduction features were extracted from velocity vector fields computed from cardiac mapping data. The divergence was used to locate ectopic foci and wavefront collisions, and the curl to identify central obstacles in reentrant circuits. Both operators were applied to simulated rhythms created from a two-dimensional cellular automaton model, to measured data from an in situ experimental canine model, and to complex three-dimensional human cardiac mapping data sets. Analysis of simulated vector fields indicated that the divergence is useful in identifying ectopic foci, with a relatively small number of vectors and with errors of up to 30 degrees in the angle measurements. The curl was useful for identifying central obstacles in reentrant circuits, and the number of velocity vectors needed increased as the rhythm became more complex. The divergence was able to accurately identify canine in situ pacing sites, areas of breakthrough activation, and wavefront collisions. In data from human arrhythmias, the divergence reliably estimated origins of electrical activity and wavefront collisions, but the curl was less reliable at locating central obstacles in reentrant circuits, possibly due to the retrospective nature of data collection. The results indicate that the curl and divergence operators applied to velocity vector maps have the potential to add valuable information in cardiac mapping and can be used to supplement human pattern recognition.

  11. Endometrial ablation by rollerball electrocoagulation compared to uterine balloon thermal ablation. Technical and safety aspects.

    NARCIS (Netherlands)

    Zon-Rabelink, I.A.A. van; Vleugels, M.P.; Merkus, J.M.W.M.; Graaf, R.M. de

    2003-01-01

    OBJECTIVE: To compare two methods of endometrial ablation, hysteroscopic rollerball electrocoagulation (RBE) and non-hysteroscopic uterine balloon thermal (UBT) ablation (Thermachoice), regarding intra- and post-operative technical complications and safety aspects. STUDY DESIGN: A randomised

  12. Anesthetic challenges in minimally invasive cardiac surgery: Are we moving in a right direction?

    Directory of Open Access Journals (Sweden)

    Vishwas Malik

    2016-01-01

    Full Text Available Continuously growing patient′s demand, technological innovation, and surgical expertise have led to the widespread popularity of minimally invasive cardiac surgery (MICS. Patient′s demand is being driven by less surgical trauma, reduced scarring, lesser pain, substantially lesser duration of hospital stay, and early return to normal activity. In addition, MICS decreases the incidence of postoperative respiratory dysfunction, chronic pain, chest instability, deep sternal wound infection, bleeding, and atrial fibrillation. Widespread media coverage, competition among surgeons and hospitals, and their associated brand values have further contributed in raising awareness among patients. In this process, surgeons and anesthesiologist have moved from the comfort of traditional wide incision surgeries to more challenging and intensively skilled MICS. A wide variety of cardiac lesions, techniques, and approaches coupled with a significant learning curve have made the anesthesiologist′s job a challenging one. Anesthesiologists facilitate in providing optimal surgical settings beginning with lung isolation, confirmation of diagnosis, cannula placement, and cardioplegia delivery. However, the concern remains and it mainly relates to patient safety, prolonged intraoperative duration, and reduced surgical exposure leading to suboptimal treatment. The risk of neurological complications, aortic injury, phrenic nerve palsy, and peripheral vascular thromboembolism can be reduced by proper preoperative evaluation and patient selection. Nevertheless, advancement in surgical instruments, perfusion practices, increasing use of transesophageal echocardiography, and accumulating experience of surgeons and anesthesiologist have somewhat helped in amelioration of these valid concerns. A patient-centric approach and clear communication between the surgeon, anesthesiologist, and perfusionist are vital for the success of MICS.

  13. Krüppel-like factor 2 is required for normal mouse cardiac development.

    Directory of Open Access Journals (Sweden)

    Aditi R Chiplunkar

    Full Text Available Krüppel-like factor 2 (KLF2 is expressed in endothelial cells in the developing heart, particularly in areas of high shear stress, such as the atrioventricular (AV canal. KLF2 ablation leads to myocardial thinning, high output cardiac failure and death by mouse embryonic day 14.5 (E14.5 in a mixed genetic background. This work identifies an earlier and more fundamental role for KLF2 in mouse cardiac development in FVB/N mice. FVB/N KLF2-/- embryos die earlier, by E11.5. E9.5 FVB/N KLF2-/- hearts have multiple, disorganized cell layers lining the AV cushions, the primordia of the AV valves, rather than the normal single layer. By E10.5, traditional and endothelial-specific FVB/N KLF2-/- AV cushions are hypocellular, suggesting that the cells accumulating at the AV canal have a defect in endothelial to mesenchymal transformation (EMT. E10.5 FVB/N KLF2-/- hearts have reduced glycosaminoglycans in the cardiac jelly, correlating with the reduced EMT. However, the number of mesenchymal cells migrating from FVB/N KLF2-/- AV explants into a collagen matrix is reduced considerably compared to wild-type, suggesting that the EMT defect is not due solely to abnormal cardiac jelly. Echocardiography of E10.5 FVB/N KLF2-/- embryos indicates that they have abnormal heart function compared to wild-type. E10.5 C57BL/6 KLF2-/- hearts have largely normal AV cushions. However, E10.5 FVB/N and C57BL/6 KLF2-/- embryos have a delay in the formation of the atrial septum that is not observed in a defined mixed background. KLF2 ablation results in reduced Sox9, UDP-glucose dehydrogenase (Ugdh, Gata4 and Tbx5 mRNA in FVB/N AV canals. KLF2 binds to the Gata4, Tbx5 and Ugdh promoters in chromatin immunoprecipitation assays, indicating that KLF2 could directly regulate these genes. In conclusion, KLF2-/- heart phenotypes are genetic background-dependent. KLF2 plays a role in EMT through its regulation of important cardiovascular genes.

  14. Clinical effects of non-ablative and ablative fractional lasers on various hair disorders: a case series of 17 patients.

    Science.gov (United States)

    Cho, Suhyun; Choi, Min Ju; Zheng, Zhenlong; Goo, Boncheol; Kim, Do-Young; Cho, Sung Bin

    2013-04-01

    Both ablative and non-ablative fractional lasers have been applied to various uncommon hair disorders. The purpose of this study was to demonstrate the clinical effects of fractional laser therapy on the course of primary follicular and perifollicular pathologies and subsequent hair regrowth. A retrospective review of 17 patients with uncommon hair disorders - including ophiasis, autosomal recessive woolly hair/hypotrichosis, various secondary cicatricial alopecias, pubic hypotrichosis, frontal fibrosing alopecia, and perifolliculitis abscedens et suffodiens - was conducted. All patients had been treated with non-ablative and/or ablative fractional laser therapies. The mean clinical improvement score in these 17 patients was 2.2, while the mean patient satisfaction score was 2.5. Of the 17 subjects, 12 (70.6%) demonstrated a clinical response to non-ablative and/or ablative fractional laser treatments, including individuals with ophiasis, autosomal recessive woolly hair/hypotrichosis, secondary cicatricial alopecia (scleroderma and pressure-induced alopecia), frontal fibrosing alopecia, and perifolliculitis abscedens et suffodiens. Conversely, patients with long-standing ophiasis, surgical scar-induced secondary cicatricial alopecia, and pubic hypotrichosis did not respond to fractional laser therapy. Our findings demonstrate that the use of non-ablative and/or ablative fractional lasers promoted hair growth in certain cases of uncommon hair disorders without any remarkable side effects.

  15. The atrial fibrillation ablation pilot study

    DEFF Research Database (Denmark)

    Arbelo, Elena; Brugada, Josep; Hindricks, Gerhard

    2014-01-01

    AIMS: The Atrial Fibrillation Ablation Pilot Study is a prospective registry designed to describe the clinical epidemiology of patients undergoing an atrial fibrillation (AFib) ablation, and the diagnostic/therapeutic processes applied across Europe. The aims of the 1-year follow-up were to analyse...... was achieved in 40.7% of patients (43.7% in paroxysmal AF; 30.2% in persistent AF; 36.7% in long-lasting persistent AF). A second ablation was required in 18% of the cases and 43.4% were under antiarrhythmic treatment. Thirty-three patients (2.5%) suffered an adverse event, 272 (21%) experienced a left atrial...... tachycardia, and 4 patients died (1 haemorrhagic stroke, 1 ventricular fibrillation in a patient with ischaemic heart disease, 1 cancer, and 1 of unknown cause). CONCLUSION: The AFib Ablation Pilot Study provided crucial information on the epidemiology, management, and outcomes of catheter ablation of AFib...

  16. Use of Intracardiac Echocardiography in Interventional Cardiology: Working With the Anatomy Rather Than Fighting It.

    Science.gov (United States)

    Enriquez, Andres; Saenz, Luis C; Rosso, Raphael; Silvestry, Frank E; Callans, David; Marchlinski, Francis E; Garcia, Fermin

    2018-05-22

    The indications for catheter-based structural and electrophysiological procedures have recently expanded to more complex scenarios, in which an accurate definition of the variable individual cardiac anatomy is key to obtain optimal results. Intracardiac echocardiography (ICE) is a unique imaging modality able to provide high-resolution real-time visualization of cardiac structures, continuous monitoring of catheter location within the heart, and early recognition of procedural complications, such as pericardial effusion or thrombus formation. Additional benefits are excellent patient tolerance, reduction of fluoroscopy time, and lack of need for general anesthesia or a second operator. For these reasons, ICE has largely replaced transesophageal echocardiography as ideal imaging modality for guiding certain procedures, such as atrial septal defect closure and catheter ablation of cardiac arrhythmias, and has an emerging role in others, including mitral valvuloplasty, transcatheter aortic valve replacement, and left atrial appendage closure. In electrophysiology procedures, ICE allows integration of real-time images with electroanatomic maps; it has a role in assessment of arrhythmogenic substrate, and it is particularly useful for mapping structures that are not visualized by fluoroscopy, such as the interatrial or interventricular septum, papillary muscles, and intracavitary muscular ridges. Most recently, a three-dimensional (3D) volumetric ICE system has also been developed, with potential for greater anatomic information and a promising role in structural interventions. In this state-of-the-art review, we provide guidance on how to conduct a comprehensive ICE survey and summarize the main applications of ICE in a variety of structural and electrophysiology procedures. © 2018 American Heart Association, Inc.

  17. Cryoballoon Catheter Ablation in Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Cevher Ozcan

    2011-01-01

    Full Text Available Pulmonary vein isolation with catheter ablation is an effective treatment in patients with symptomatic atrial fibrillation refractory or intolerant to antiarrhythmic medications. The cryoballoon catheter was recently approved for this procedure. In this paper, the basics of cryothermal energy ablation are reviewed including its ability of creating homogenous lesion formation, minimal destruction to surrounding vasculature, preserved tissue integrity, and lower risk of thrombus formation. Also summarized here are the publications describing the clinical experience with the cryoballoon catheter ablation in both paroxysmal and persistent atrial fibrillation, its safety and efficacy, and discussions on the technical aspect of the cryoballoon ablation procedure.

  18. Radiofrequency ablation of rabbit liver in vivo: effect of the Pringle maneuver on pathologic changes in liver surrounding the ablation zone

    International Nuclear Information System (INIS)

    Kim, Seung Kwon; Lim, Hyo K; Ryu, Jeong Ah

    2004-01-01

    We wished to evaluate the effect of the Pringle maneuver (occlusion of both the hepatic artery and portal vein) on the pathologic changes in the hepatic vessels, bile ducts and liver parenchyma surrounding the ablation zone in rabbit livers. Radiofrequency (RF) ablation zones were created in the livers of 24 rabbits in vivo by using a 50-W, 480-kHz monopolar RF generator and a 15-gauge expandable electrode with four sharp prongs for 7 mins. The tips of the electrodes were placed in the liver parenchyma near the porta hepatis with the distal 1 cm of their prongs deployed. Radiofrequency ablation was performed in the groups with (n=12 rabbits) and without (n=12 rabbits) the Pringle maneuver. Three animals of each group were sacrificed immediately, three days (the acute phase), seven days (the early subacute phase) and two weeks (the late subacute phase) after RF ablation. The ablation zones were excised and serial pathologic changes in the hepatic vessels, bile ducts and liver parenchyma surrounding the ablation zone were evaluated. With the Pringle maneuver, portal vein thrombosis was found in three cases (in the immediate [n=2] and acute phase [n=1]), bile duct dilatation adjacent to the ablation zone was found in one case (in the late subacute phase [n=1]), infarction adjacent to the ablation zone was found in three cases (in the early subacute [n=2] and late subacute [n=1] phases). None of the above changes was found in the livers ablated without the Pringle maneuver. On the microscopic findings, centrilobular congestion, sinusoidal congestion, sinusoidal platelet and neutrophilic adhesion, and hepatocyte vacuolar and ballooning changes in liver ablated with Pringle maneuver showed more significant changes than in those livers ablated without the Pringle maneuver (ρ < 0.05). Radiofrequency ablation with the Pringle maneuver created more severe pathologic changes in the portal vein, bile ducts and liver parenchyma surrounding the ablation zone compared with RF

  19. Traumatic Tricuspid Insufficiency Requiring Valve Repair in an Acute Setting.

    Science.gov (United States)

    Enomoto, Yoshinori; Sudo, Yoshio; Sueta, Tomonori

    2015-01-01

    Tricuspid insufficiency due to penetrating cardiac trauma is rare. Patients with tricuspid insufficiency due to trauma can tolerate this abnormality for months or even years. We report a case of a 66-year-old female with penetrating cardiac trauma on the right side of her heart that required tricuspid valve repair in an acute setting. She sustained cut and stab wounds on her bilateral forearms and in the neck and epigastric region. She had cardiac tamponade and developed pulseless electrical activity, which required emergency surgery. The right ventricle and superior vena cava were dissected approximately 5 cm and 2 cm, respectively. After these wounds had been repaired, the patient's inability to wean from cardiopulmonary bypass suggested rightsided heart failure; transesophageal echocardiography revealed tricuspid insufficiency. Right atriotomy was performed, and a detailed examination revealed that the tricuspid valve septal leaflet was split in two. There was also an atrial septal injury that created a connection with the left atrium; these injuries were not detected from the right ventricular wound. After repair, weaning from cardiopulmonary bypass with mild tricuspid insufficiency was achieved, and she recovered uneventfully. This case emphasized the importance of thoroughly investigating intracardiac injury and transesophageal echocardiography.

  20. Image integration into 3-dimensional-electro-anatomical mapping system facilitates safe ablation of ventricular arrhythmias originating from the aortic root and its vicinity.

    Science.gov (United States)

    Jularic, Mario; Akbulak, Ruken Özge; Schäffer, Benjamin; Moser, Julia; Nuehrich, Jana; Meyer, Christian; Eickholt, Christian; Willems, Stephan; Hoffmann, Boris A

    2018-03-01

    During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map. Published on behalf of the European Society of Cardiology. All rights reserved.

  1. Radiofrequency ablation of osteoid osteoma

    NARCIS (Netherlands)

    Vanderschueren, Geert Maria Joris Michael

    2009-01-01

    The main purpose of this thesis was to evaluate the effectiveness and safety of CT-guided radiofrequency ablation for the treatment of spinal and non-spinal osteoid osteomas. Furthermore, the technical requirements needed for safe radiofrequency ablation and the clinical outcome after radiofrequency

  2. Image-guided radiofrequency ablation of renal cell carcinoma

    International Nuclear Information System (INIS)

    Boss, Andreas; Clasen, Stephan; Pereira, Philippe L.; Kuczyk, Markus; Schick, Fritz

    2007-01-01

    The incidence of renal cell carcinoma is rising with the increased number of incidental detection of small tumours. During the past few years, percutaneous imaging-guided radiofrequency ablation has evolved as a minimally invasive treatment of small unresectable renal tumours offering reduced patient morbidity and overall health care costs. In radiofrequency ablation, thermal energy is deposited into a targeted tumour by means of a radiofrequency applicator. In recent studies, radiofrequency ablation was shown to be an effective and safe modality for local destruction of renal cell carcinoma. Radiofrequency applicator navigation can be performed via ultrasound, computed tomography or magnetic resonance guidance; however, ultrasound seems less favourable because of the absence of monitoring capabilities during ablation. On-line monitoring of treatment outcome can only be performed with magnetic resonance imaging giving the possibility of eventual applicator repositioning to ablate visible residual tumour tissue. Long-term follow-up is crucial to assess completeness of tumour ablation. New developments in ablation technology and radiological equipment will further increase the indication field for radiofrequency ablation of renal cell carcinoma. Altogether, radiofrequency ablation seems to be a promising new modality for the minimally invasive treatment of renal cell carcinoma, which was demonstrated to exhibit high short-term effectiveness. (orig.)

  3. Percutaneous radiofrequency thermal ablation of lung VX2 tumors in a rabbit model: evaluation with helical CT findings for the complete and partal ablation

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Gong Yong; Han, Young Min; Lim, Yeong Su; Jang, Kyu Yun; Lee, Sang Yong; Chung, Gyung Ho [School of Medicine, Chonbuk National Univ., Chonju (Korea, Republic of)

    2004-05-01

    To evaluate the radiologic findings for complete and partial ablation after percutaneous CT-guided transthoracic radiofrequency ablation (RFA) of lung VX2 tumor implanted in rabbits. Thirteen rabbits with successfully implanted lung VX2 were used. Three rabbits as controls did not receive RFA while the other ten rabbits underwent RFA; 5 complete and 5 partial. RFA was performed using an internally cooled, 17-gauge electrode (Radionics, Burlington, MA) with a 1-cm active tip under CT guidance. Postprocedural CT was performed within 3 days, and we analyzed the ablated size, enhancement pattern, shape, margin, and complications of the complete and partial ablation groups. Rabbits were sacrificed after postprocedural CT with an overdose of ketamine, and pathologic findings of the ablated groups were compared with those of the control group. The size of the ablated lesions and the enhancement pattern differed between the completely and partially ablated groups on chest CT. The size of the ablated lesions was increased by 47.1% in the completely ablated group and by 2.1% in the partially ablated group. In the completely ablated group, VX2 tumor showed absolutely no enhancement, whereas only ablated pulmonary parenchyma outside VX2 showed mild enhancement on enhanced CT. In the partial ablated group, a part of VX2 became strongly enhanced on enhanced CT. On microscopic examination, the completely ablated group demonstrated that a viable tumor cell was not visible. In the partially ablated group, however, a viable tumor cell within the surrounding fibrous capsule on the peripheral area of the VX2 was observed. The important CT findings for evaluation of complete and partial RFA are the ablated size and enhancement pattern of the ablated lesion.

  4. Convergent ablation measurements of plastic ablators in gas-filled rugby hohlraums on OMEGA

    Science.gov (United States)

    Casner, A.; Jalinaud, T.; Masse, L.; Galmiche, D.

    2015-10-01

    Indirect-drive implosions experiments were conducted on the Omega Laser Facility to test the performance of uniformly doped plastic ablators for Inertial Confinement Fusion. The first convergent ablation measurements in gas-filled rugby hohlraums are reported. Ignition relevant limb velocities in the range from 150 to 300 μm .n s-1 have been reached by varying the laser drive energy and the initial capsule aspect ratio. The measured capsule trajectory and implosion velocity are in good agreement with 2D integrated simulations and a zero-dimensional modeling of the implosions. We demonstrate experimentally the scaling law for the maximum implosion velocity predicted by the improved rocket model [Y. Saillard, Nucl. Fusion 46, 1017 (2006)] in the high-ablation regime case.

  5. Hard tissue ablation with a spray-assisted mid-IR laser

    International Nuclear Information System (INIS)

    Kang, H W; Rizoiu, I; Welch, A J

    2007-01-01

    The objective of this study was to understand the dominant mechanism(s) for dental enamel ablation with the application of water spray. A free-running Er,Cr:YSGG (yttrium, scandium, gallium, garnet) laser was used to ablate human enamel tissue at various radiant exposures. During dental ablation, distilled water was sprayed on the sample surface, and these results were compared to ablation without a spray (dry ablation). In order to identify dominant ablation mechanisms, transient acoustic waves were compared to ablation thresholds and the volume of material removed. The ablation profile and depth were measured using optical coherence tomography (OCT). Irregular surface modification, charring and peripheral cracks were associated with dry ablation, whereas craters for spray samples were relatively clean without thermal damage. In spite of a 60% higher ablation threshold for spray associated irradiations owing to water absorption, acoustic peak pressures were six times higher and ablation volume was up to a factor of 2 larger compared to dry ablation. The enhanced pressure and ablation performance of the spray-assisted process was the result of rapid water vaporization, material ejection with recoil stress, interstitial water explosion and possibly liquid-jet formation. With water cooling and abrasive/disruptive mechanical effects, the spray ablation can be a safe and efficient modality for dental treatment

  6. Hard tissue ablation with a spray-assisted mid-IR laser

    Science.gov (United States)

    Kang, H. W.; Rizoiu, I.; Welch, A. J.

    2007-12-01

    The objective of this study was to understand the dominant mechanism(s) for dental enamel ablation with the application of water spray. A free-running Er,Cr:YSGG (yttrium, scandium, gallium, garnet) laser was used to ablate human enamel tissue at various radiant exposures. During dental ablation, distilled water was sprayed on the sample surface, and these results were compared to ablation without a spray (dry ablation). In order to identify dominant ablation mechanisms, transient acoustic waves were compared to ablation thresholds and the volume of material removed. The ablation profile and depth were measured using optical coherence tomography (OCT). Irregular surface modification, charring and peripheral cracks were associated with dry ablation, whereas craters for spray samples were relatively clean without thermal damage. In spite of a 60% higher ablation threshold for spray associated irradiations owing to water absorption, acoustic peak pressures were six times higher and ablation volume was up to a factor of 2 larger compared to dry ablation. The enhanced pressure and ablation performance of the spray-assisted process was the result of rapid water vaporization, material ejection with recoil stress, interstitial water explosion and possibly liquid-jet formation. With water cooling and abrasive/disruptive mechanical effects, the spray ablation can be a safe and efficient modality for dental treatment.

  7. Fractional ablative laser skin resurfacing: a review.

    Science.gov (United States)

    Tajirian, Ani L; Tarijian, Ani L; Goldberg, David J

    2011-12-01

    Ablative laser technology has been in use for many years now. The large side effect profile however has limited its use. Fractional ablative technology is a newer development which combines a lesser side effect profile along with similar efficacy. In this paper we review fractional ablative laser skin resurfacing.

  8. Percutaneous Septal Ablation in Hypertrophic Obstructive Cardiomyopathy: From Experiment to Standard of Care

    Directory of Open Access Journals (Sweden)

    Lothar Faber

    2014-01-01

    Full Text Available Hypertrophic cardiomyopathy (HCM is one of the more common hereditary cardiac conditions. According to presence or absence of outflow obstruction at rest or with provocation, a more common (about 60–70% obstructive type of the disease (HOCM has to be distinguished from the less common (30–40% nonobstructive phenotype (HNCM. Symptoms include exercise limitation due to dyspnea, angina pectoris, palpitations, or dizziness; occasionally syncope or sudden cardiac death occurs. Correct diagnosis and risk stratification with respect to prophylactic ICD implantation are essential in HCM patient management. Drug therapy in symptomatic patients can be characterized as treatment of heart failure with preserved ejection fraction (HFpEF in HNCM, while symptoms and the obstructive gradient in HOCM can be addressed with beta-blockers, disopyramide, or verapamil. After a short overview on etiology, natural history, and diagnostics in hypertrophic cardiomyopathy, this paper reviews the current treatment options for HOCM with a special focus on percutaneous septal ablation. Literature data and the own series of about 600 cases are discussed, suggesting a largely comparable outcome with respect to procedural mortality, clinical efficacy, and long-term outcome.

  9. Role of high-resolution image integration to visualize left phrenic nerve and coronary arteries during epicardial ventricular tachycardia ablation.

    Science.gov (United States)

    Yamashita, Seigo; Sacher, Frédéric; Mahida, Saagar; Berte, Benjamin; Lim, Han S; Komatsu, Yuki; Amraoui, Sana; Denis, Arnaud; Derval, Nicolas; Laurent, François; Montaudon, Michel; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre; Cochet, Hubert

    2015-04-01

    Epicardial ventricular tachycardia (VT) ablation is associated with risks of coronary artery (CA) and phrenic nerve (PN) injury. We investigated the role of multidetector computed tomography in visualizing CA and PN during VT ablation. Ninety-five consecutive patients (86 men; age, 57 ± 15) with VT underwent cardiac multidetector computed tomography. The PN detection rate and anatomic variability were analyzed. In 49 patients undergoing epicardial mapping, real-time multidetector computed tomographic integration was used to display CAs/PN locations in 3-dimensional mapping systems. Elimination of local abnormal ventricular activities (LAVAs) was used as ablation end point. The distribution of CAs/PN with respect to LAVA was analyzed and compared between VT etiologies. Multidetector computed tomography detected PN in 81 patients (85%). Epicardial LAVAs were observed in 44 of 49 patients (15 ischemic cardiomyopathy, 15 nonischemic cardiomyopathy, and 14 arrhythmogenic right ventricular cardiomyopathy) with a mean of 35 ± 37 LAVA points/patient. LAVAs were located within 1 cm from CAs and PN in 35 (80%) and 18 (37%) patients, respectively. The prevalence of LAVA adjacent to CAs was higher in nonischemic cardiomyopathy and arrhythmogenic right ventricular cardiomyopathy than in ischemic cardiomyopathy (100% versus 86% versus 53%; P < 0.01). The prevalence of LAVAs adjacent to PN was higher in nonischemic cardiomyopathy than in ischemic cardiomyopathy (93% versus 27%; P < 0.001). Epicardial ablation was performed in 37 patients (76%). Epicardial LAVAs could not be eliminated because of the proximity to CAs or PN in 8 patients (18%). The epicardial electrophysiological VT substrate is often close to CAs and PN in patients with nonischemic cardiomyopathy. High-resolution image integration is potentially useful to minimize risks of PN and CA injury during epicardial VT ablation. © 2015 American Heart Association, Inc.

  10. Chemically assisted laser ablation ICP mass spectrometry.

    Science.gov (United States)

    Hirata, Takafumi

    2003-01-15

    A new laser ablation technique combined with a chemical evaporation reaction has been developed for elemental ratio analysis of solid samples using an inductively coupled plasma mass spectrometer (ICPMS). Using a chemically assisted laser ablation (CIA) technique developed in this study, analytical repeatability of the elemental ratio measurement was successively improved. To evaluate the reliability of the CLA-ICPMS technique, Pb/U isotopic ratios were determined for zircon samples that have previously been analyzed by other techniques. Conventional laser ablation for Pb/U shows a serious elemental fractionation during ablation mainly due to the large difference in elemental volatility between Pb and U. In the case of Pb/U ratio measurement, a Freon R-134a gas (1,1,1,2-tetrafluoroethane) was introduced into the laser cell as a fluorination reactant. The Freon gas introduced into the laser cell reacts with the ablated sample U, and refractory U compounds are converted to a volatile U fluoride compound (UF6) under the high-temperature condition at the ablation site. This avoids the redeposition of U around the ablation pits. Although not all the U is reacted with Freon, formation of volatile UF compounds improves the transmission efficiency of U. Typical precision of the 206Pb/238U ratio measurement is 3-5% (2sigma) for NIST SRM 610 and Nancy 91500 zircon standard, and the U-Pb age data obtained here show good agreement within analytical uncertainties with the previously reported values. Since the observed Pb/U ratio for solid samples is relatively insensitive to laser power and ablation time, optimization of ablation conditions or acquisition parameters no longer needs to be performed on a sample-to-sample basis.

  11. [Fever, atrial fibrillation, and angina pectoris in a 58-year-old man].

    Science.gov (United States)

    Groebner, M; Südhoff, T; Doering, M; Kirmayer, M; Nitsch, T; Prügl, L; Römer, W; Wolf, H; Tacke, J; Massoudy, P; Nüsse, T; Elsner, D

    2014-05-01

    Primary cardiac lymphoma (PCL) respresents a very rare type of cardiac tumour. This report illustrates a case of PCL in an immunocompetent 58-year-old man presenting with atrial fibrillation and febrile syndrome. Comprehensive imaging [computer tomography (CT), cardiac magnetic resonance imaging (cMRI), 3-dimensional transesophageal echocardiography (3D-TEE)] identified a large right atrial tumour, leading to pericardial effusion. Isolated cardiac involvement was confirmed by positron emission tomography (PET)-CT. A diffuse large B-cell lymphoma (DLBCL) was diagnosed based on the results of a TEE-guided biopsy. A normalized PET scan (PETAL study) indicated complete remission following R-CHOP 14 immunochemotherapy. Thus, an interdisciplinary and multimodal approach avoided unnecessary cardiac surgery.

  12. Virtual In-Silico Modeling Guided Catheter Ablation Predicts Effective Linear Ablation Lesion Set for Longstanding Persistent Atrial Fibrillation: Multicenter Prospective Randomized Study.

    Science.gov (United States)

    Shim, Jaemin; Hwang, Minki; Song, Jun-Seop; Lim, Byounghyun; Kim, Tae-Hoon; Joung, Boyoung; Kim, Sung-Hwan; Oh, Yong-Seog; Nam, Gi-Byung; On, Young Keun; Oh, Seil; Kim, Young-Hoon; Pak, Hui-Nam

    2017-01-01

    Objective: Radiofrequency catheter ablation for persistent atrial fibrillation (PeAF) still has a substantial recurrence rate. This study aims to investigate whether an AF ablation lesion set chosen using in-silico ablation (V-ABL) is clinically feasible and more effective than an empirically chosen ablation lesion set (Em-ABL) in patients with PeAF. Methods: We prospectively included 108 patients with antiarrhythmic drug-resistant PeAF (77.8% men, age 60.8 ± 9.9 years), and randomly assigned them to the V-ABL ( n = 53) and Em-ABL ( n = 55) groups. Five different in-silico ablation lesion sets [1 pulmonary vein isolation (PVI), 3 linear ablations, and 1 electrogram-guided ablation] were compared using heart-CT integrated AF modeling. We evaluated the feasibility, safety, and efficacy of V-ABL compared with that of Em-ABL. Results: The pre-procedural computing time for five different ablation strategies was 166 ± 11 min. In the Em-ABL group, the earliest terminating blinded in-silico lesion set matched with the Em-ABL lesion set in 21.8%. V-ABL was not inferior to Em-ABL in terms of procedure time ( p = 0.403), ablation time ( p = 0.510), and major complication rate ( p = 0.900). During 12.6 ± 3.8 months of follow-up, the clinical recurrence rate was 14.0% in the V-ABL group and 18.9% in the Em-ABL group ( p = 0.538). In Em-ABL group, clinical recurrence rate was significantly lower after PVI+posterior box+anterior linear ablation, which showed the most frequent termination during in-silico ablation (log-rank p = 0.027). Conclusions: V-ABL was feasible in clinical practice, not inferior to Em-ABL, and predicts the most effective ablation lesion set in patients who underwent PeAF ablation.

  13. Successful thrombectomy of a stuck mechanical prosthetic mitral valve guided by perioperative transesophageal echocardiography and cinefluoroscopy

    Directory of Open Access Journals (Sweden)

    Paulo César Gobert Damasceno Campos

    2009-03-01

    Full Text Available We describe the case of a 53-year-old man with past history of rheumatic valvular disease who developed acute decompensated heart failure due to thrombosis of his mechanical mitral valve prosthesis. The diagnosis was established after a combined and complementary approach of echocardiography and cinefluoroscopy. Because of the severe heart failure at presentation, the patient was taken to surgery. The intraoperative transesophageal echocardiography was critical to guide a successful thrombectomy procedure. Postoperative pathological findings revealed the presence of thrombus and fibrotic tissue (pannus in the surgical specimens removed from the valve. The success of this case and the treatment choice are supported by the most recent literature data on prosthetic valve thrombosis. We highlight the use of three diagnostic approaches in our patient: echocardiography, cinefluoroscopy and pathology.

  14. Aorto-right atrial fistula after Bentall repair.

    Science.gov (United States)

    Howard, Charles E; Velasco, Carlos E; Roullard, Christina P; Rafael, Aldo

    2017-07-01

    We describe a man with the Marfan syndrome and a prior ascending aortic aneurysm resection who presented with knee pain and concern of endocarditis. Transesophageal echocardiogram showed no vegetations, and computed tomography angiogram of the heart showed a possible pseudoaneurysm. Cardiac catheterization and aortogram revealed the diagnosis of an aorto-right atrial fistula, which was then operatively repaired. This case highlights the role that cardiac catheterization with aortogram can play in the detection of aorto-atrial fistula.

  15. Pilot Study: Estimation of Stroke Volume and Cardiac Output from Pulse Wave Velocity.

    Directory of Open Access Journals (Sweden)

    Yurie Obata

    Full Text Available Transesophageal echocardiography (TEE is increasingly replacing thermodilution pulmonary artery catheters to assess hemodynamics in patients at high risk for cardiovascular morbidity. However, one of the drawbacks of TEE compared to pulmonary artery catheters is the inability to measure real time stroke volume (SV and cardiac output (CO continuously. The aim of the present proof of concept study was to validate a novel method of SV estimation, based on pulse wave velocity (PWV in patients undergoing cardiac surgery.This is a retrospective observational study. We measured pulse transit time by superimposing the radial arterial waveform onto the continuous wave Doppler waveform of the left ventricular outflow tract, and calculated SV (SVPWV using the transformed Bramwell-Hill equation. The SV measured by TEE (SVTEE was used as a reference.A total of 190 paired SV were measured from 28 patients. A strong correlation was observed between SVPWV and SVTEE with the coefficient of determination (R2 of 0.71. A mean difference between the two (bias was 3.70 ml with the limits of agreement ranging from -20.33 to 27.73 ml and a percentage error of 27.4% based on a Bland-Altman analysis. The concordance rate of two methods was 85.0% based on a four-quadrant plot. The angular concordance rate was 85.9% with radial limits of agreement (the radial sector that contained 95% of the data points of ± 41.5 degrees based on a polar plot.PWV based SV estimation yields reasonable agreement with SV measured by TEE. Further studies are required to assess its utility in different clinical situations.

  16. Short and middle term outcome of radiofrequency catheter ablation for paroxysmal and sustained atrial fibrillation

    International Nuclear Information System (INIS)

    Okamoto, Mitsunori; Sueda, Takashi; Hashimoto, Masaki; Fukuda, Yukihiro; Iwamoto, Akimichi; Matsumoto, Takeshi; Shintani, Yumiko; Iwasaki, Toshitaka; Kinoshita, Hiroki

    2009-01-01

    The aim of this study was to assess short and middle term outcome of radiofrequency catheter ablation for drug-refractory paroxysmal and sustained atrial fibrillation. Subjects were 30 patients of atrial fibrillation (19 paroxysmal, 11 sustained) who underwent extensive pulmonary vein isolation from January 2007 to August 2009 in our department. Twenty three men and seven women, aged from 44 to 76 years, were enrolled. Follow-up period was one to 32 months. Drug free success was 33%, but symptoms and electrocardiogram (EGG) findings were improved in 93 % of the patients by administration of anti-arrhythmic agents. Five of the six patients with bradycardia-tachycardia syndrome was free from pacemaker implantation. Left ventricular ejection fraction was improved in two patients with dilated cardiomyopathy (DCM)-like left ventricular dysfunction. One case had cardiac tamponade and transient ST elevation due to right coronary air embolism were observed in two cases. There were no death and no cerebrovascular events during the procedures and follow-up periods. In conclusion, radiofrequency catheter ablation for paroxysmal and sustained atrial fibrillation in our department may be highly acceptable new method for improving the symptoms and clinical signs of the patients. (author)

  17. Automated planning of ablation targets in atrial fibrillation treatment

    Science.gov (United States)

    Keustermans, Johannes; De Buck, Stijn; Heidbüchel, Hein; Suetens, Paul

    2011-03-01

    Catheter based radio-frequency ablation is used as an invasive treatment of atrial fibrillation. This procedure is often guided by the use of 3D anatomical models obtained from CT, MRI or rotational angiography. During the intervention the operator accurately guides the catheter to prespecified target ablation lines. The planning stage, however, can be time consuming and operator dependent which is suboptimal both from a cost and health perspective. Therefore, we present a novel statistical model-based algorithm for locating ablation targets from 3D rotational angiography images. Based on a training data set of 20 patients, consisting of 3D rotational angiography images with 30 manually indicated ablation points, a statistical local appearance and shape model is built. The local appearance model is based on local image descriptors to capture the intensity patterns around each ablation point. The local shape model is constructed by embedding the ablation points in an undirected graph and imposing that each ablation point only interacts with its neighbors. Identifying the ablation points on a new 3D rotational angiography image is performed by proposing a set of possible candidate locations for each ablation point, as such, converting the problem into a labeling problem. The algorithm is validated using a leave-one-out-approach on the training data set, by computing the distance between the ablation lines obtained by the algorithm and the manually identified ablation points. The distance error is equal to 3.8+/-2.9 mm. As ablation lesion size is around 5-7 mm, automated planning of ablation targets by the presented approach is sufficiently accurate.

  18. Depth-resolved registration of transesophageal echo to x-ray fluoroscopy using an inverse geometry fluoroscopy system

    Energy Technology Data Exchange (ETDEWEB)

    Hatt, Charles R. [Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Tomkowiak, Michael T.; Dunkerley, David A. P.; Slagowski, Jordan M. [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Funk, Tobias [Triple Ring Technologies, Inc., Newark, California 94560 (United States); Raval, Amish N. [Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Speidel, Michael A., E-mail: speidel@wisc.edu [Departments of Medical Physics and Medicine, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2015-12-15

    Purpose: Image registration between standard x-ray fluoroscopy and transesophageal echocardiography (TEE) has recently been proposed. Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system designed for cardiac procedures. This study presents a method for 3D registration of SBDX and TEE images based on the tomosynthesis and 3D tracking capabilities of SBDX. Methods: The registration algorithm utilizes the stack of tomosynthetic planes produced by the SBDX system to estimate the physical 3D coordinates of salient key-points on the TEE probe. The key-points are used to arrive at an initial estimate of the probe pose, which is then refined using a 2D/3D registration method adapted for inverse geometry fluoroscopy. A phantom study was conducted to evaluate probe pose estimation accuracy relative to the ground truth, as defined by a set of coregistered fiducial markers. This experiment was conducted with varying probe poses and levels of signal difference-to-noise ratio (SDNR). Additional phantom and in vivo studies were performed to evaluate the correspondence of catheter tip positions in TEE and x-ray images following registration of the two modalities. Results: Target registration error (TRE) was used to characterize both pose estimation and registration accuracy. In the study of pose estimation accuracy, successful pose estimates (3D TRE < 5.0 mm) were obtained in 97% of cases when the SDNR was 5.9 or higher in seven out of eight poses. Under these conditions, 3D TRE was 2.32 ± 1.88 mm, and 2D (projection) TRE was 1.61 ± 1.36 mm. Probe localization error along the source-detector axis was 0.87 ± 1.31 mm. For the in vivo experiments, mean 3D TRE ranged from 2.6 to 4.6 mm and mean 2D TRE ranged from 1.1 to 1.6 mm. Anatomy extracted from the echo images appeared well aligned when projected onto the SBDX images. Conclusions: Full 6 DOF image registration between SBDX and TEE is feasible and accurate to within 5 mm. Future studies will focus on

  19. Depth-resolved registration of transesophageal echo to x-ray fluoroscopy using an inverse geometry fluoroscopy system

    International Nuclear Information System (INIS)

    Hatt, Charles R.; Tomkowiak, Michael T.; Dunkerley, David A. P.; Slagowski, Jordan M.; Funk, Tobias; Raval, Amish N.; Speidel, Michael A.

    2015-01-01

    Purpose: Image registration between standard x-ray fluoroscopy and transesophageal echocardiography (TEE) has recently been proposed. Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system designed for cardiac procedures. This study presents a method for 3D registration of SBDX and TEE images based on the tomosynthesis and 3D tracking capabilities of SBDX. Methods: The registration algorithm utilizes the stack of tomosynthetic planes produced by the SBDX system to estimate the physical 3D coordinates of salient key-points on the TEE probe. The key-points are used to arrive at an initial estimate of the probe pose, which is then refined using a 2D/3D registration method adapted for inverse geometry fluoroscopy. A phantom study was conducted to evaluate probe pose estimation accuracy relative to the ground truth, as defined by a set of coregistered fiducial markers. This experiment was conducted with varying probe poses and levels of signal difference-to-noise ratio (SDNR). Additional phantom and in vivo studies were performed to evaluate the correspondence of catheter tip positions in TEE and x-ray images following registration of the two modalities. Results: Target registration error (TRE) was used to characterize both pose estimation and registration accuracy. In the study of pose estimation accuracy, successful pose estimates (3D TRE < 5.0 mm) were obtained in 97% of cases when the SDNR was 5.9 or higher in seven out of eight poses. Under these conditions, 3D TRE was 2.32 ± 1.88 mm, and 2D (projection) TRE was 1.61 ± 1.36 mm. Probe localization error along the source-detector axis was 0.87 ± 1.31 mm. For the in vivo experiments, mean 3D TRE ranged from 2.6 to 4.6 mm and mean 2D TRE ranged from 1.1 to 1.6 mm. Anatomy extracted from the echo images appeared well aligned when projected onto the SBDX images. Conclusions: Full 6 DOF image registration between SBDX and TEE is feasible and accurate to within 5 mm. Future studies will focus on

  20. Osteoid Osteoma: Experience with Laser- and Radiofrequency-Induced Ablation

    International Nuclear Information System (INIS)

    Gebauer, Bernhard; Tunn, Per-Ulf; Gaffke, Gunnar; Melcher, Ingo; Felix, Roland; Stroszczynski, Christian

    2006-01-01

    The purpose of this study was to analyze the clinical outcome of osteoid osteoma treated by thermal ablation after drill opening. A total of 17 patients and 20 procedures were included. All patients had typical clinical features (age, pain) and a typical radiograph showing a nidus. In 5 cases, additional histological specimens were acquired. After drill opening of the osteoid osteoma nidus, 12 thermal ablations were induced by laser interstitial thermal therapy (LITT) (9F Power-Laser-Set; Somatex, Germany) and 8 ablations by radiofrequency ablation (RFA) (RITA; StarBurst, USA). Initial clinical success with pain relief has been achieved in all patients after the first ablation. Three patients had an osteoid osteoma recurrence after 3, 9, and 10 months and were successfully re-treated by thermal ablation. No major complication and one minor complication (sensible defect) were recorded. Thermal ablation is a safe and minimally invasive therapy option for osteoid osteoma. Although the groups are too small for a comparative analysis, we determined no difference between laser- and radiofrequency-induced ablation in clinical outcome after ablation

  1. Profound Obstructive Hypotension From Prone Positioning Documented by Transesophageal Echocardiography in a Patient With Scoliosis: A Case Report.

    Science.gov (United States)

    Abcejo, Arnoley S; Diaz Soto, Juan; Castoro, Courtney; Armour, Sarah; Long, Timothy R

    2017-08-01

    In a healthy 12-year-old female with scoliosis, prone positioning resulted in pressor-refractory cardiovascular collapse. Resumption of supine position immediately improved hemodynamics. Intraoperative transesophageal echocardiography (TEE) revealed a collapsed left atrium and biventricular failure. Repeat prone positioning resulted in a recurrence of hypotension. However, hemodynamic stabilization was restored and maintained by repositioning chest pads caudally. The patient successfully underwent a 6-hour scoliosis repair without perioperative morbidity. With this case, we aim to: (1) reintroduce awareness of this mechanical obstructive cause of reversible hypotension; (2) highlight the use of intraoperative TEE during prone hemodynamic collapse; and (3) suggest an alternative prone positioning technique if chest compression results in hemodynamic instability.

  2. Femtosecond laser ablation of dentin

    International Nuclear Information System (INIS)

    Alves, S; Vilar, R; Oliveira, V

    2012-01-01

    The surface morphology, structure and composition of human dentin treated with a femtosecond infrared laser (pulse duration 500 fs, wavelength 1030 nm, fluences ranging from 1 to 3 J cm -2 ) was studied by scanning electron microscopy, x-ray diffraction, x-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. The average dentin ablation threshold under these conditions was 0.6 ± 0.2 J cm -2 and the ablation rate achieved in the range 1 to 2 µm/pulse for an average fluence of 3 J cm -2 . The ablation surfaces present an irregular and rugged appearance, with no significant traces of melting, deformation, cracking or carbonization. The smear layer was entirely removed by the laser treatment. For fluences only slightly higher than the ablation threshold the morphology of the laser-treated surfaces was very similar to the dentin fracture surfaces and the dentinal tubules remained open. For higher fluences, the surface was more porous and the dentin structure was partially concealed by ablation debris and a few resolidified droplets. Independently on the laser processing parameters and laser processing method used no sub-superficial cracking was observed. The dentin constitution and chemical composition was not significantly modified by the laser treatment in the processing parameter range used. In particular, the organic matter is not preferentially removed from the surface and no traces of high temperature phosphates, such as the β-tricalcium phosphate, were observed. The achieved results are compatible with an electrostatic ablation mechanism. In conclusion, the high beam quality and short pulse duration of the ultrafast laser used should allow the accurate preparation of cavities, with negligible damage of the underlying material. (paper)

  3. Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference.

    Science.gov (United States)

    Suh, Young Joo; Lee, Sak; Im, Dong Jin; Chang, Suyon; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Choi, Byoung Wook; Chang, Byung-Chul; Shim, Chi Young; Hong, Geu-Ru; Kim, Young Jin

    2016-07-01

    The added value of cardiac computed tomography (CT) with transesophageal echocardiography (TEE) for evaluating mechanical aortic valve (AV) dysfunction has not yet been investigated. The purposes of this study were to investigate the added value of cardiac CT for evaluation of mechanical AVs and diagnoses of pannus compared to TEE, with surgical findings of redo-aortic valve replacement (AVR) used as a standard reference. 25 patients who underwent redo-AVR due to mechanical AV dysfunction and cardiac CT before redo-AVR were included. The presence of pannus, encroachment ratio by pannus, and limitation of motion (LOM) were evaluated on CT. The diagnostic performance of pannus detection was compared using TEE, CT, and CT+TEE, with surgical findings as a standard reference. The added value of CT for diagnosing the cause of mechanical AV dysfunction was assessed compared to TTE+TEE. In two patients, CT analysis was not feasible due to severe metallic artifacts. On CT, pannus and LOM were found in 100% (23/23) and 60.9% (14/23). TEE identified pannus in 48.0% of patients (12/25). CT, TEE, and CT+TEE correctly identified pannus with sensitivity of 92.0%, 48.0%, and 92.0%, respectively (P=0.002 for CT vs. TEE). In 11 of 13 cases (84.6%) with inconclusive or negative TEE results for pannus, CT detected the pannus. Among 13 inconclusive cases of TTE+TEE for the cause of mechanical AV dysfunction, CT suggested 6 prosthetic valve obstruction (PVO) by pannus, 4 low-flow low-gradient PVO, and one LOM without significant PVO. Cardiac CT showed added diagnostic value with TEE in the detection of pannus as the cause of mechanical AV dysfunction. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Laser ablation of microparticles for nanostructure generation

    International Nuclear Information System (INIS)

    Waraich, Palneet Singh; Tan, Bo; Venkatakrishnan, Krishnan

    2011-01-01

    The process of laser ablation of microparticles has been shown to generate nanoparticles from microparticles; but the generation of nanoparticle networks from microparticles has never been reported before. We report a unique approach for the generation of nanoparticle networks through ablation of microparticles. Using this approach, two samples containing microparticles of lead oxide (Pb 3 O 4 ) and nickel oxide (NiO), respectively, were ablated under ambient conditions using a femtosecond laser operating in the MHz repetition rate regime. Nanoparticle networks with particle diameter ranging from 60 to 90 nm were obtained by ablation of microparticles without use of any specialized equipment, catalysts or external stimulants. The formation of finer nanoparticle networks has been explained by considering the low pressure region created by the shockwave, causing rapid condensation of microparticles into finer nanoparticles. A comparison between the nanostructures generated by ablating microparticle and those by ablating bulk substrate was carried out; and a considerable reduction in size and narrowed size distribution was observed. Our nanostructure fabrication technique will be a unique process for nanoparticle network generation from a vast array of materials.

  5. Percutaneous tumor ablation in medical radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Mack, M.G. [University Hospital Frankfurt Univ. (Germany). Inst. for Diagnostic and Interventional Radiology; Helmberger, T.K. [Klinikum Bogenhausen, Academic Teaching Hospital of the Technical Univ. Munich (Germany). Dept. for Diagnostic and Interventional Radiology and Nuclear Medicine; Reiser, M.F. (eds.) [University Hospitals - Grosshadern and Innenstadt Munich Univ. (Germany). Dept. of Clinical Radiology

    2008-07-01

    Thermal ablation has become an integral part of oncology, especially in the field of interventional oncology. This very comprehensive book encompasses the different technologies employed in thermal ablation, its indications and the results achieved in various clinical conditions. The first part of the book clearly explains the basics of thermal ablative techniques such as laser-induced thermotherapy, radiofrequency ablation, microwave ablation, cryotherapy, and localized tumor therapy. The latest developments in the application of minimally invasive therapies in localized neoplastic disease are demonstrated. In the main part of the book, techniques of guiding the applicators to the target structures by use of different imaging tools such as ultrasound, computed tomography and magnetic resonance imaging are discussed. The results are presented for a variety of clinical indications, including liver and lung tumors and metastases and some rather rare conditions involving the kidney, the head and neck, the prostate, and soft tissue structures. A large number of acknowledged experts have contributed to the book, which benefits from a lucid structure and excellent images. (orig.)

  6. Percutaneous tumor ablation in medical radiology

    International Nuclear Information System (INIS)

    Vogl, T.J.; Mack, M.G.; Helmberger, T.K.; Reiser, M.F.

    2008-01-01

    Thermal ablation has become an integral part of oncology, especially in the field of interventional oncology. This very comprehensive book encompasses the different technologies employed in thermal ablation, its indications and the results achieved in various clinical conditions. The first part of the book clearly explains the basics of thermal ablative techniques such as laser-induced thermotherapy, radiofrequency ablation, microwave ablation, cryotherapy, and localized tumor therapy. The latest developments in the application of minimally invasive therapies in localized neoplastic disease are demonstrated. In the main part of the book, techniques of guiding the applicators to the target structures by use of different imaging tools such as ultrasound, computed tomography and magnetic resonance imaging are discussed. The results are presented for a variety of clinical indications, including liver and lung tumors and metastases and some rather rare conditions involving the kidney, the head and neck, the prostate, and soft tissue structures. A large number of acknowledged experts have contributed to the book, which benefits from a lucid structure and excellent images. (orig.)

  7. Mechanisms of recurrent aortic regurgitation after aortic valve repair: predictive value of intraoperative transesophageal echocardiography.

    Science.gov (United States)

    le Polain de Waroux, Jean-Benoît; Pouleur, Anne-Catherine; Robert, Annie; Pasquet, Agnès; Gerber, Bernhard L; Noirhomme, Philippe; El Khoury, Gébrine; Vanoverschelde, Jean-Louis J

    2009-08-01

    The aim of the present study was to examine the intraoperative echocardiographic features associated with recurrent severe aortic regurgitation (AR) after an aortic valve repair surgery. Surgical valve repair for AR has significant advantages over valve replacement, but little is known about the predictors and mechanisms of its failure. We blindly reviewed all clinical, pre-operative, intraoperative, and follow-up transesophageal echocardiographic data of 186 consecutive patients who underwent valve repair for AR during a 10-year period and in whom intraoperative and follow-up echo data were available. After a median follow-up duration of 18 months, 41 patients had recurrent 3+ AR, 23 patients presented with residual 1+ to 2+ AR, and 122 had no or trivial AR. In patients with recurrent 3+ AR, the cause of recurrent AR was the rupture of a pericardial patch in 3 patients, a residual cusp prolapse in 26 patients, a restrictive cusp motion in 9 patients, an aortic dissection in 2 patients, and an infective endocarditis in 1 patient. Pre-operatively, all 3 groups were similar for aortic root dimensions and prevalence of bicuspid valve (overall 37%). Patients with recurrent AR were more likely to display Marfan syndrome or type 3 dysfunction pre-operatively. At the opposite end, patients with continent AR repair at follow-up were more likely to have type 2 dysfunction pre-operatively. After cardiopulmonary bypass, a shorter coaptation length, the degree of cusp billowing, a lower level of coaptation (relative to the annulus), a larger diameter of the aortic annulus and the sino-tubular junction, the presence of a residual AR, and the width of its vena contracta were associated with the presence of AR at follow-up. Multivariate Cox analysis identified a shorter coaptation length (odds ratio [OR]: 0.8, p = 0.05), a coaptation occurring below the level of the aortic annulus (OR: 7.9, p < 0.01), a larger aortic annulus (OR: 1.2, p = 0.01), and residual aortic regurgitation

  8. Twist1 Controls a Cell-Specification Switch Governing Cell Fate Decisions within the Cardiac Neural Crest

    Science.gov (United States)

    Vincentz, Joshua W.; Firulli, Beth A.; Lin, Andrea; Spicer, Douglas B.; Howard, Marthe J.; Firulli, Anthony B.

    2013-01-01

    Neural crest cells are multipotent progenitor cells that can generate both ectodermal cell types, such as neurons, and mesodermal cell types, such as smooth muscle. The mechanisms controlling this cell fate choice are not known. The basic Helix-loop-Helix (bHLH) transcription factor Twist1 is expressed throughout the migratory and post-migratory cardiac neural crest. Twist1 ablation or mutation of the Twist-box causes differentiation of ectopic neuronal cells, which molecularly resemble sympathetic ganglia, in the cardiac outflow tract. Twist1 interacts with the pro-neural factor Sox10 via its Twist-box domain and binds to the Phox2b promoter to repress transcriptional activity. Mesodermal cardiac neural crest trans-differentiation into ectodermal sympathetic ganglia-like neurons is dependent upon Phox2b function. Ectopic Twist1 expression in neural crest precursors disrupts sympathetic neurogenesis. These data demonstrate that Twist1 functions in post-migratory neural crest cells to repress pro-neural factors and thereby regulate cell fate determination between ectodermal and mesodermal lineages. PMID:23555309

  9. Acoustic signal emission monitoring as a novel method to predict steam pops during radiofrequency ablation: preliminary observations.

    Science.gov (United States)

    Chik, William W B; Kosobrodov, Roman; Bhaskaran, Abhishek; Barry, Michael Anthony Tony; Nguyen, Doan Trang; Pouliopoulos, Jim; Byth, Karen; Sivagangabalan, Gopal; Thomas, Stuart P; Ross, David L; McEwan, Alistair; Kovoor, Pramesh; Thiagalingam, Aravinda

    2015-04-01

    Steam pop is an explosive rupture of cardiac tissue caused by tissue overheating above 100 °C, resulting in steam formation, predisposing to serious complications associated with radiofrequency (RF) ablations. However, there are currently no reliable techniques to predict the occurrence of steam pops. We propose the utility of acoustic signals emitted during RF ablation as a novel method to predict steam pop formation and potentially prevent serious complications. Radiofrequency generator parameters (power, impedance, and temperature) were temporally recorded during ablations performed in an in vitro bovine myocardial model. The acoustic system consisted of HTI-96-min hydrophone, microphone preamplifier, and sound card connected to a laptop computer. The hydrophone has the frequency range of 2 Hz to 30 kHz and nominal sensitivity in the range -240 to -165 dB. The sound was sampled at 96 kHz with 24-bit resolution. Output signal from the hydrophone was fed into the camera audio input to synchronize the video stream. An automated system was developed for the detection and analysis of acoustic events. Nine steam pops were observed. Three distinct sounds were identified as warning signals, each indicating rapid steam formation and its release from tissue. These sounds had a broad frequency range up to 6 kHz with several spectral peaks around 2-3 kHz. Subjectively, these warning signals were perceived as separate loud clicks, a quick succession of clicks, or continuous squeaking noise. Characteristic acoustic signals were identified preceding 80% of pops occurrence. Six cardiologists were able to identify 65% of acoustic signals accurately preceding the pop. An automated system identified the characteristic warning signals in 85% of cases. The mean time from the first acoustic signal to pop occurrence was 46 ± 20 seconds. The automated system had 72.7% sensitivity and 88.9% specificity for predicting pops. Easily identifiable characteristic acoustic emissions

  10. Anatomic relationship between left coronary artery and left atrium in patients undergoing atrial fibrillation ablation.

    Science.gov (United States)

    Anselmino, Matteo; Torri, Federica; Ferraris, Federico; Calò, Leonardo; Castagno, Davide; Gili, Sebastiano; Rovera, Chiara; Giustetto, Carla; Gaita, Fiorenzo

    2017-07-01

    Atrial fibrillation transcatheter ablation (TCA) is, within available atrial fibrillation rhythm control strategies, one of the most effective. To potentially improve ablation outcome in case of recurrent atrial fibrillation after a first procedure or in presence of structural myocardial disease, isolation of the pulmonary veins may be associated with extensive lesions within the left atrium. To avoid rare, but potentially life-threatening, complications, thorough knowledge and assessment of left atrium anatomy and its relation to structures in close proximity are, therefore, mandatory. Aim of the present study is to describe, by cardiac computed tomography, the anatomic relationship between aortic root, left coronary artery and left atrium in patients undergoing atrial fibrillation TCA. The cardiac computed tomography scan of 21 patients affected by atrial fibrillation was elaborated to segment left atrium, aortic root and left coronary artery from the surrounding structures and the following distances measured: left atrium and aortic root; left atrium roof and aortic root; left main coronary artery and left atrium; circumflex artery and left atrium appendage; and circumflex artery and mitral valve annulus. Above all, the median distance between left atrium and aortic root (1.9, 1.5-2.1 mm), and between circumflex artery and left atrium appendage ostium (3.0, 2.1-3.4 mm) were minimal (≤3 mm). None of measured distances significantly varied between patients presenting paroxysmal versus persistent atrial fibrillation. The anatomic relationship between left atrium and coronary arteries is extremely relevant when performing atrial fibrillation TCA by extensive lesions. Therefore, at least in the latter case, preablation imaging should be recommended to avoid rare, but potentially life-threatening, complications with the aim of an as well tolerated as possible procedure.

  11. Investigation of ultrashort pulse laser ablation of solid targets by measuring the ablation-generated momentum using a torsion pendulum.

    Science.gov (United States)

    Zhang, Nan; Wang, Wentao; Zhu, Xiaonong; Liu, Jiansheng; Xu, Kuanhong; Huang, Peng; Zhao, Jiefeng; Li, Ruxin; Wang, Mingwei

    2011-04-25

    50 fs - 12 ps laser pulses are employed to ablate aluminum, copper, iron, and graphite targets. The ablation-generated momentum is measured with a torsion pendulum. Corresponding time-resolved shadowgraphic measurements show that the ablation process at the optimal laser fluence achieving the maximal momentum is primarily dominated by the photomechanical mechanism. When laser pulses with specific laser fluence are used and the pulse duration is tuned from 50 fs to 12 ps, the generated momentum firstly increases and then remains almost constant, which could be attributed to the change of the ablation mechanism involved from atomization to phase explosion. The investigation of the ablation-generated momentum also reveals a nonlinear momentum-energy conversion scaling law, namely, as the pulse energy increases, the momentum obtained by the target increases nonlinearly. This may be caused by the effective reduction of the dissipated energy into the surrounding of the ablation zone as the pulse energy increases, which indicates that for femtosecond laser the dissipated energy into the surrounding target is still significant.

  12. Frequency of left atrial thrombus detected by transesophageal echocardiography in patients of tight mitral stenosis having negative trans-thoracic echocardiography at gulab devi cardiac complex

    International Nuclear Information System (INIS)

    Fayyaz, A.; Iqbal, M.W.

    2014-01-01

    Introduction: Patients with mitral stenosis (MS) having atrial fibrillation (AF) are more prone to develop left atrial (LA) thrombus. Systemic embolism, related to LA thrombus is a well-known risk of Percutaneous Mitral Balloon Valvotomy (PMBV) of the mitral valve. Therefore presence of LA thrombus is a contraindication to PMBV. Objective: Objective of this study was to detect the frequency of LA thrombus by transesophageal echocardiography (TEE) in patients of tight MS in whom transthoracic echocardiography (TTE) could not detect any LA thrombus. Patients and Methods: In this cross sectional study, we took 100 indoor patients with tight MS on non-probability consecutive sampling. Data was collected after meeting inclusion criteria. Patients were taken in this study after acquiring written informed consent. Symptoms were inquired from all patients and functional status was assessed by New York Heart Association class. Unstable patients were medically managed before the procedure. TEE was done on the same day before undergoing PMBV to look for clot in LA. Results: The mean age of the patients was 32.20 years and SD was 11.3 years. There were 36(36%) male patients and 64(64%) female patients. LA thrombus was present in 40% of patients on TEE out of which 19 were male patients (52.77%) and 21 were female patients (32.81%). Conclusion: Patients with mitral stenosis having AF are more prone to develop LA thrombus. In this study, the frequency of LA thrombus was 40% recorded, which is high. Due to the potential risk of embolization, it is strongly recommended to perform TEE in patients with normal TTE study before undergoing PMBV. The presence of a LA thrombus should be considered a contraindication to the PMBV of the mitral valve. (author)

  13. Femtosecond laser ablation of enamel

    Science.gov (United States)

    Le, Quang-Tri; Bertrand, Caroline; Vilar, Rui

    2016-06-01

    The surface topographical, compositional, and structural modifications induced in human enamel by femtosecond laser ablation is studied. The laser treatments were performed using a Yb:KYW chirped-pulse-regenerative amplification laser system (560 fs and 1030 nm) and fluences up to 14 J/cm2. The ablation surfaces were studied by scanning electron microscopy, grazing incidence x-ray diffraction, and micro-Raman spectroscopy. Regardless of the fluence, the ablation surfaces were covered by a layer of resolidified material, indicating that ablation is accompanied by melting of hydroxyapatite. This layer presented pores and exploded gas bubbles, created by the release of gaseous decomposition products of hydroxyapatite (CO2 and H2O) within the liquid phase. In the specimen treated with 1-kHz repetition frequency and 14 J/cm2, thickness of the resolidified material is in the range of 300 to 900 nm. The micro-Raman analysis revealed that the resolidified material contains amorphous calcium phosphate, while grazing incidence x-ray diffraction analysis allowed detecting traces of a calcium phosphate other than hydroxyapatite, probably β-tricalcium phosphate Ca3), at the surface of this specimen. The present results show that the ablation of enamel involves melting of enamel's hydroxyapatite, but the thickness of the altered layer is very small and thermal damage of the remaining material is negligible.

  14. Development of new anatomy reconstruction software to localize cardiac isochrones to the cardiac surface from the 12 lead ECG.

    Science.gov (United States)

    van Dam, Peter M; Gordon, Jeffrey P; Laks, Michael M; Boyle, Noel G

    2015-01-01

    Non-invasive electrocardiographic imaging (ECGI) of the cardiac muscle can help the pre-procedure planning of the ablation of ventricular arrhythmias by reducing the time to localize the origin. Our non-invasive ECGI system, the cardiac isochrone positioning system (CIPS), requires non-intersecting meshes of the heart, lungs and torso. However, software to reconstruct the meshes of the heart, lungs and torso with the capability to check and prevent these intersections is currently lacking. Consequently the reconstruction of a patient specific model with realistic atrial and ventricular wall thickness and incorporating blood cavities, lungs and torso usually requires additional several days of manual work. Therefore new software was developed that checks and prevents any intersections, and thus enables the use of accurate reconstructed anatomical models within CIPS. In this preliminary study we investigated the accuracy of the created patient specific anatomical models from MRI or CT. During the manual segmentation of the MRI data the boundaries of the relevant tissues are determined. The resulting contour lines are used to automatically morph reference meshes of the heart, lungs or torso to match the boundaries of the morphed tissue. Five patients were included in the study; models of the heart, lungs and torso were reconstructed from standard cardiac MRI images. The accuracy was determined by computing the distance between the segmentation contours and the morphed meshes. The average accuracy of the reconstructed cardiac geometry was within 2mm with respect to the manual segmentation contours on the MRI images. Derived wall volumes and left ventricular wall thickness were within the range reported in literature. For each reconstructed heart model the anatomical heart axis was computed using the automatically determined anatomical landmarks of the left apex and the mitral valve. The accuracy of the reconstructed heart models was well within the accuracy of the used

  15. Delayed Development of Pneumothorax After Pulmonary Radiofrequency Ablation

    International Nuclear Information System (INIS)

    Clasen, Stephan; Kettenbach, Joachim; Kosan, Bora; Aebert, Hermann; Schernthaner, Melanie; Kroeber, Stefan-Martin; Boemches, Andrea; Claussen, Claus D.; Pereira, Philippe L.

    2009-01-01

    Acute pneumothorax is a frequent complication after percutaneous pulmonary radiofrequency (RF) ablation. In this study we present three cases showing delayed development of pneumothorax after pulmonary RF ablation in 34 patients. Our purpose is to draw attention to this delayed complication and to propose a possible approach to avoid this major complication. These three cases occurred subsequent to 44 CT-guided pulmonary RF ablation procedures (6.8%) using either internally cooled or multitined expandable RF electrodes. In two patients, the pneumothorax, being initially absent at the end of the intervention, developed without symptoms. One of these patients required chest drain placement 32 h after RF ablation, and in the second patient therapy remained conservative. In the third patient, a slight pneumothorax at the end of the intervention gradually increased and led into tension pneumothorax 5 days after ablation procedure. Underlying bronchopleural fistula along the coagulated former electrode track was diagnosed in two patients. In conclusion, delayed development of pneumothorax after pulmonary RF ablation can occur and is probably due to underlying bronchopleural fistula, potentially leading to tension pneumothorax. Patients and interventionalists should be prepared for delayed onset of this complication, and extensive track ablation following pulmonary RF ablation should be avoided.

  16. Steady ablation on the surface of a two-layer composite

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Wen-Shan [Chung Shan Institute of Science and Technology, P.O. Box 90008-15-3, Lung-Tan, Tao-Yuan, 32526 Taiwan (China)

    2005-12-01

    Discovered is a quasi-steady ablation phenomenon on the surface of a two-layer composite which is formed by a layer of ablative material and another layer of non-ablative substrate. Theoretical exact solutions of quasi-steady ablation rate, the associated temperature distribution and end-of-ablation time of this two-layer composite are derived. A criterion for the occurrence of quasi-steady ablation is presented also. A one-dimensional transient numerical model is developed to perform a number of numerical experiments and hence to verify the correctness of the above theoretical solutions for the current quasi-steady ablation phenomenon. Based on the current results, a new method of measuring the ablation (or sublimation) heat is also proposed. (author)

  17. Radiofrequency catheter ablation of idiopathic ventricular arrhythmias originating from intramural foci in the left ventricular outflow tract: efficacy of sequential versus simultaneous unipolar catheter ablation.

    Science.gov (United States)

    Yamada, Takumi; Maddox, William R; McElderry, H Thomas; Doppalapudi, Harish; Plumb, Vance J; Kay, G Neal

    2015-04-01

    Idiopathic ventricular arrhythmias (VAs) originating from the left ventricular outflow tract (LVOT) sometimes require catheter ablation from the endocardial and epicardial sides for their elimination, suggesting the presence of intramural VA foci. This study investigated the efficacy of sequential and simultaneous unipolar radiofrequency catheter ablation from the endocardial and epicardial sides in treating intramural LVOT VAs. Fourteen consecutive LVOT VAs, which required sequential or simultaneous irrigated unipolar radiofrequency ablation from the endocardial and epicardial sides for their elimination, were studied. The first ablation was performed at the site with the earliest local ventricular activation and best pace map on the endocardial or epicardial side. When the first ablation was unsuccessful, the second ablation was delivered on the other surface. If this sequential unipolar ablation failed, simultaneous unipolar ablation from both sides was performed. The first ablation was performed on the epicardial side in 9 VAs and endocardial side in 5 VAs. The intramural LVOT VAs were successfully eliminated by the sequential (n=9) or simultaneous (n=5) unipolar catheter ablation. Simultaneous ablation was most likely to be required for the elimination of the VAs when the distance between the endocardial and epicardial ablation sites was >8 mm and the earliest local ventricular activation time relative to the QRS onset during the VAs of sequential unipolar radiofrequency ablation and sometimes required simultaneous ablation from both the endocardial and epicardial sides. © 2015 American Heart Association, Inc.

  18. A multicentre randomized-controlled trial of inhaled milrinone in high-risk cardiac surgical patients.

    Science.gov (United States)

    Denault, André Y; Bussières, Jean S; Arellano, Ramiro; Finegan, Barry; Gavra, Paul; Haddad, François; Nguyen, Anne Q N; Varin, France; Fortier, Annik; Levesque, Sylvie; Shi, Yanfen; Elmi-Sarabi, Mahsa; Tardif, Jean-Claude; Perrault, Louis P; Lambert, Jean

    2016-10-01

    Inhaled milrinone (iMil) has been used for the treatment of pulmonary hypertension (PH) but its efficacy, safety, and prophylactic effects in facilitating separation from cardiopulmonary bypass (CPB) and preventing right ventricular (RV) dysfunction have not yet been evaluated in a clinical trial. The purpose of this study was to investigate if iMil administered before CPB would be superior to placebo in facilitating separation from CPB. High-risk cardiac surgical patients with PH were randomized to receive iMil or placebo after the induction of anesthesia and before CPB. Hemodynamic parameters and RV function were evaluated by means of pulmonary artery catheterization and transesophageal echocardiography. The groups were compared for the primary outcome of the level of difficulty in weaning from CPB. Among the secondary outcomes examined were the reduction in the severity of PH, the incidence of RV failure, and mortality. Of the 124 patients randomized, the mean (standard deviation [SD]) EuroSCORE II was 8.0 (2.6), and the baseline mean (SD) systolic pulmonary artery pressure (SPAP) was 53 (9) mmHg. The use of iMil was associated with increases in cardiac output (P = 0.03) and a reduction in SPAP (P = 0.04) with no systemic hypotension. Nevertheless, there was no difference in the combined incidence of difficult or complex separation from CPB between the iMil and control groups (30% vs 28%, respectively; absolute difference, 2%; 95% confidence interval [CI], -14 to 18; P = 0.78). There was also no difference in RV failure between the iMil and control groups (15% vs 14%, respectively; difference, 1%; 95% CI, -13 to 12; P = 0.94). Mortality was increased in patients with RV failure vs those without (22% vs 2%, respectively; P < 0.001). In high-risk cardiac surgery patients with PH, the prophylactic use of iMil was associated with favourable hemodynamic effects that did not translate into improvement of clinically relevant endpoints. This trial was registered at

  19. Bimodal electric tissue ablation (BETA) - in-vivo evaluation of the effect of applying direct current before and during radiofrequency ablation of porcine liver

    International Nuclear Information System (INIS)

    Cockburn, J.F.; Maddern, G.J.; Wemyss-Holden, S.A.

    2007-01-01

    Aim: To examine the effect of applying increasing amounts of direct current (DC) before and during alternating current radiofrequency ablation of porcine liver. Materials and methods: Using a Radiotherapeutics RF3000 generator, a 9 V AC/DC transformer and a 16 G plain aluminium tube as an electrode, a control group of 24 porcine hepatic radiofrequency ablation zones was compared with 24 zones created using a bimodal electric tissue ablation (BETA) technique in three pigs. All ablations were terminated when tissue impedance rose to greater than 999 Ω or radiofrequency energy input fell below 5 W on three successive measurements taken at 1 min intervals. BETA ablations were performed in two phases: an initial phase of variable duration DC followed by a second phase during which standard radiofrequency ablation was applied simultaneously with DC. During this second phase, radiofrequency power input was regulated by the feedback circuitry of the RF3000 generator according to changes in tissue impedance. The diameters (mm) of each ablation zone were measured by two observers in two planes perpendicular to the plane of needle insertion. The mean short axis diameter of each ablation zone was subjected to statistical analysis. Results: With increased duration of prior application of DC, there was a progressive increase in the diameter of the ablation zone (p < 0.001). This effect increased sharply up to 300 s of pre-treatment after which a further increase in diameter occurred, but at a much lesser rate. A maximum ablation zone diameter of 32 mm was produced (control diameters 10-13 mm). Conclusion: Applying a 9 V DC to porcine liver in vivo, and continuing this DC application during subsequent radiofrequency ablation, results in larger ablation zone diameters compared with radiofrequency ablation alone

  20. Endometrial ablation: normal appearance and complications.

    Science.gov (United States)

    Drylewicz, Monica R; Robinson, Kathryn; Siegel, Cary Lynn

    2018-03-14

    Global endometrial ablation is a commonly performed, minimally invasive technique aimed at improving/resolving abnormal uterine bleeding and menorrhagia in women. As non-resectoscopic techniques have come into existence, endometrial ablation performance continues to increase due to accessibility and decreased requirements for operating room time and advanced technical training. The increased utilization of this method translates into increased imaging of patients who have undergone the procedure. An understanding of the expected imaging appearances of endometrial ablation using different modalities is important for the abdominal radiologist. In addition, the frequent usage of the technique naturally comes with complications requiring appropriate imaging work-up. We review the expected appearance of the post-endometrial ablated uterus on multiple imaging modalities and demonstrate the more common and rare complications seen in the immediate post-procedural time period and remotely.

  1. A comparison of microwave ablation and bipolar radiofrequency ablation both with an internally cooled probe: Results in ex vivo and in vivo porcine livers

    International Nuclear Information System (INIS)

    Yu Jie; Liang Ping; Yu Xiaoling; Liu Fangyi; Chen Lei; Wang Yang

    2011-01-01

    Purpose: The purpose of this study was to compare the effectiveness of microwave (MW) ablation and radiofrequency (RF) ablation using a single internally cooled probe in a hepatic porcine model. Materials and methods: In the ex vivo experiment, MW ablations (n = 40) were performed with a 2450 MHz and 915 MHz needle antenna, respectively at 60 W, 70 W power settings. Bipolar RF ablations (n = 20) were performed with a 3-cm (T30) and 4-cm (T40) active tip needle electrodes, respectively at a rated power 30 W and 40 W according to automatically systematic power setting. In the in vivo experiment, the 2450 MHz and 915 MHz MW ablation both at 60 W and T30 bipolar RF ablation at 30 W were performed (n = 30). All of the application time were 10 min. Long-axis diameter (Dl), short-axis diameter (Ds), ratio of Ds/Dl, the temperature data 5 mm from the needle and the time of temperature 5 mm from the needle rising to 54 deg. C were measured. Results: Both in ex vivo and in vivo models, Ds and Dl of 915 MHz MW ablations were significantly larger than all the RF ablations (P < 0.05); the Ds for all the 2450 MHz MW ablations were significantly larger than that of T30 RF ablations (P < 0.05). 2450 MHz MW and T30 RF ablation tended to produce more elliptical-shaped ablation zone. Tissue temperatures 5 mm from the needle were considerably higher with MW ablation, meanwhile MW ablation achieved significantly faster rate of temperature rising to 54 deg. C than RF ablation. For in vivo study after 10 min of ablation, the Ds and Dl of 2450 MHz MW, 915 MHz MW and Bipolar RF were 2.35 ± 0.75, 2.95 ± 0.32, 1.61 ± 0.33 and 3.86 ± 0.81, 5.79 ± 1.03, 3.21 ± 0.51, respectively. Highest tissue temperatures 5 mm from the needle were 80.07 ± 12.82 deg. C, 89.07 ± 3.52 deg. C and 65.56 ± 15.31 deg. C and the time of temperature rising to 54 deg. C were respectively 37.50 ± 7.62 s, 24.50 ± 4.09 s and 57.29 ± 23.24 s for three applicators. Conclusion: MW ablation may have higher

  2. Nephron-sparing percutaneous ablation of a 5 cm renal cell carcinoma by superselective embolization and percutaneous RF-ablation

    International Nuclear Information System (INIS)

    Tacke, J.; Mahnken, A.; Buecker, A.; Guenther, R.W.; Rohde, D.

    2001-01-01

    Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 μm) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow up CT one day and 4 weeks after the radiofrequency intervention revealed no signs of residual tumor growth. Conclusion: The combined transcatheter embolization and percutaneous radiofrequency ablation of renal cell carcinoma has proved technically feasible, effective, and safe in this patient. It may be offered as an alternative treatment to partial or radical nephrectomy under certain circumstances. Abbreviations: RF = radiofrequency ablation; CT = computed tomography; HIV = human immunodeficiency virus. (orig.) [de

  3. Comparison of the Three NIF Ablators

    Energy Technology Data Exchange (ETDEWEB)

    Kritcher, A. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Clark, D. S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haan, S. W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Yi, S. A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Zylstra, A. B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ralph, J. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Weber, C. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-11-01

    Indirect drive implosion experiments on NIF have now been performed using three different ablator materials: glow discharge polymer (GDP) or CH, high density carbon (HDC, which we also refer to as diamond), and sputtered beryllium (Be). It has been appreciated for some time that each of these materials has specific advantages and disadvantages as an ICF ablator.[1-4] In light of experiments conducted on NIF in the last few years, how do these ablators compare? Given current understanding, is any ablator more or less likely to reach ignition on NIF? Has the understanding of their respective strengths and weaknesses changed since NIF experiments began? How are those strengths and weaknesses highlighted by implosion designs currently being tested or planned for testing soon? This document aims to address these questions by combining modern simulation results with a survey of the current experimental data base. More particularly, this document is meant to fulfill an L2 Milestone for FY17 to “Document our understanding of the relative advantages and disadvantages of CH, HDC, and Be designs.” Note that this document does not aim to recommend a down-selection of the current three ablator choices. It is intended only to gather and document the current understanding of the differences between these ablators and thereby inform the choices made in planning future implosion experiments. This document has two themes: (i) We report on a reanalysis project in which post-shot simulations were done on a common basis for layered shots using each ablator. This included data from keyholes, 2D ConA, and so forth, from each campaign, leading up to the layered shots. (“Keyholes” are shots dedicated to measuring the shock timing in a NIF target, as described in Ref. 5. “2DConAs” are backlit implosions in which the symmetry of the implosion is measured between about half and full convergence, as described in Ref. 6.) This set of common-basis postshot simulations is compared to

  4. Radioiodine Remnant Ablation: A Critical Review

    International Nuclear Information System (INIS)

    Bal, Chandra Sekhar; Padhy, Ajit Kumar

    2015-01-01

    Radioiodine remnant ablation (RRA) is considered a safe and effective method for eliminating residual thyroid tissue, as well as microscopic disease if at all present in thyroid bed following thyroidectomy. The rationale of RRA is that in the absence of thyroid tissue, serum thyroglobulin (Tg) measurement can be used as an excellent tumor marker. Other considerations are like the presence of significant remnant thyroid tissue makes detection and treatment of nodal or distant metastases difficult. Rarely, microscopic disease in the thyroid bed if not ablated, in the future, could be a source of anaplastic transformation. On the other hand, microscopic tumor emboli in distant sites could be the cause of distant metastasis too. The ablation of remnant tissue would in all probability eliminate these theoretical risks. It may be noted that all these are unproven contentious issues except postablation serum Tg estimation that could be a good tumor marker for detecting early biochemical recurrence in long-term follow-up strategy. Radioactive iodine is administered as a form of “adjuvant therapy” for remnant ablation. There have been several reports with regard to the administered dose for remnant ablation. The first report of a prospective randomized clinical trial was published from India by a prospective randomized study conducted at the All India Institute of Medical Sciences, New Delhi in the year 1996. The study reported that increasing the empirical 131 I initial dose to more than 50 mCi results in plateauing of the dose-response curve and thus, conventional high-dose remnant ablation needs critical evaluation. Recently, two important studies were published: One from French group and the other from UK on a similar line. Interestingly, all three studies conducted in three different geographical regions of the world showed exactly similar conclusion. The new era of low-dose remnant ablation has taken a firm scientific footing across the continents

  5. Fracture in Phenolic Impregnated Carbon Ablator

    Science.gov (United States)

    Agrawal, Parul; Chavez-Garcia, Jose; Pham, John

    2013-01-01

    This paper describes the development of a novel technique to understand the failure mechanisms inside thermal protection materials. The focus of this research is on the class of materials known as phenolic impregnated carbon ablators. It has successfully flown on the Stardust spacecraft and is the thermal protection system material chosen for the Mars Science Laboratory and SpaceX Dragon spacecraft. Although it has good thermal properties, structurally, it is a weak material. To understand failure mechanisms in carbon ablators, fracture tests were performed on FiberForm(Registered TradeMark) (precursor), virgin, and charred ablator materials. Several samples of these materials were tested to investigate failure mechanisms at a microstructural scale. Stress-strain data were obtained simultaneously to estimate the tensile strength and toughness. It was observed that cracks initiated and grew in the FiberForm when a critical stress limit was reached such that the carbon fibers separated from the binder. However, both for virgin and charred carbon ablators, crack initiation and growth occurred in the matrix (phenolic) phase. Both virgin and charred carbon ablators showed greater strength values compared with FiberForm samples, confirming that the presence of the porous matrix helps in absorbing the fracture energy.

  6. Radiofrequency Ablation of Hepatic Cysts : Case Report

    International Nuclear Information System (INIS)

    Lee, Ye Ri; Kim, Pyo Nyun

    2005-01-01

    Radiofrequency ablation has been frequently performed on intra-hepatic solid tumor, namely, hepatocellular carcinoma, metastatic tumor and cholangio carcinoma, for take the cure. But, the reports of radiofrequency ablation for intrahepatic simple cysts are few. In vitro experiment of animal and in vivo treatment for intrahepatic cysts of human had been reported in rare cases. We report 4 cases of radiofrequency ablation for symptomatic intrahepatic cysts

  7. 2D shear-wave ultrasound elastography (SWE) evaluation of ablation zone following radiofrequency ablation of liver lesions: is it more accurate?

    Science.gov (United States)

    Bo, Xiao W; Li, Xiao L; Guo, Le H; Li, Dan D; Liu, Bo J; Wang, Dan; He, Ya P; Xu, Xiao H

    2016-01-01

    Objective: To evaluate the usefulness of two-dimensional quantitative ultrasound shear-wave elastography (2D-SWE) [i.e. virtual touch imaging quantification (VTIQ)] in assessing the ablation zone after radiofrequency ablation (RFA) for ex vivo swine livers. Methods: RFA was performed in 10 pieces of fresh ex vivo swine livers with a T20 electrode needle and 20-W output power. Conventional ultrasound, conventional strain elastography (SE) and VTIQ were performed to depict the ablation zone 0 min, 10 min, 30 min and 60 min after ablation. On VTIQ, the ablation zones were evaluated qualitatively by evaluating the shear-wave velocity (SWV) map and quantitatively by measuring the SWV. The ultrasound, SE and VTIQ results were compared against gross pathological and histopathological specimens. Results: VTIQ SWV maps gave more details about the ablation zone, the central necrotic zone appeared as red, lateral necrotic zone as green and transitional zone as light green, from inner to exterior, while the peripheral unablated liver appeared as blue. Conventional ultrasound and SE, however, only marginally depicted the whole ablation zone. The volumes of the whole ablation zone (central necrotic zone + lateral necrotic zone + transitional zone) and necrotic zone (central necrotic zone + lateral necrotic zone) measured by VTIQ showed excellent correlation (r = 0.915, p  0.05). Conclusion: The quantitative 2D-SWE of VTIQ is useful for the depiction of the ablation zone after RFA and it facilitates discrimination of different areas in the ablation zone qualitatively and quantitatively. This elastography technique might be useful for the therapeutic response evaluation instantly after RFA. Advances in knowledge: A new quantitative 2D-SWE (i.e. VTIQ) for evaluation treatment response after RFA is demonstrated. It facilitates discrimination of the different areas in the ablation zone qualitatively and quantitatively and may be useful for the therapeutic

  8. Neutral and plasma shielding model for pellet ablation

    International Nuclear Information System (INIS)

    Houlberg, W.A.; Milora, S.L.; Attenberger, S.E.

    1987-10-01

    The neutral gas shielding model for ablation of frozen hydrogenic pellets is extended to include the effects of an initial Maxwelliam distribution of incident electron energies; a cold plasma shield outside the neutral shield and extended along the magnetic field; energetic neutral beam ions and alpha particles; and self-limiting electron ablation in the collisionless plasma limit. Including the full electron distribution increases ablation, but adding the cold ionized shield reduces ablation; the net effect is a modest reduction in pellet penetration compared with the monoenergetic electron neutral shielding model with no plasma shield. Unlike electrons, fast ions can enter the neutral shield directly without passing through the cold ionized shield because their gyro-orbits are typically larger than the diameter of the cold plasma tube. Fast alpha particles should not enhance the ablation rate unless their population exceeds that expected from local classical thermalization. Fast beam ions, however, may enhance ablation in the plasma periphery if their population is high enough. Self-limiting ablation in the collisionless limit leads to a temporary distortion of the original plasma electron Maxwellian distribution function through preferential depopulation of the higher-energy electrons. 23 refs., 9 figs

  9. Intraoperative Diagnosis of Stanford Type A Dissection by Transesophageal Echocardiogram in a Patient Presenting for Renal Transplantation

    Directory of Open Access Journals (Sweden)

    William R. Hand

    2011-01-01

    Full Text Available A 48-year-old patient with hypertensive end-stage renal disease presented for cadaveric renal transplantation. On physical exam, a previously undocumented diastolic murmur was heard loudest at the left lower sternal border. The patient had a history of pericardial effusions and reported “a feeling of chest fullness” when lying flat. As such, a transesophageal echocardiogram (TEE was performed after induction of anesthesia to evaluate the pericardial space and possibly determine the etiology and severity of the new murmur. The TEE revealed a Stanford Type A aortic dissection. The renal transplant was cancelled (organ reassigned within region, and the patient underwent an urgent ascending and proximal hemiarch aortic replacement. This case demonstrates the importance of a thorough physical exam and highlights the utility of TEE for noncardiac surgical cases.

  10. Modeling CO2 Laser Ablative Impulse with Polymers

    International Nuclear Information System (INIS)

    Sinko, John E.; Phipps, Claude R.; Sasoh, Akihiro

    2010-01-01

    Laser ablation vaporization models have usually ignored the spatial dependence of the laser beam. Here, we consider effects from modeling using a Gaussian beam for both photochemical and photothermal conditions. The modeling results are compared to experimental and literature data for CO 2 laser ablation of the polymer polyoxymethylene under vacuum, and discussed in terms of the ablated mass areal density and momentum coupling coefficient. Extending the scope of discussion, laser ablative impulse generation research has lacked a cohesive strategy for linking the vaporization and plasma regimes. Existing models, mostly formulated for ultraviolet laser systems or metal targets, appear to be inappropriate or impractical for applications requiring CO 2 laser ablation of polymers. A recently proposed method for linking the vaporization and plasma regimes for analytical modeling is addressed here along with the implications of its use. Key control parameters are considered, along with the major propulsion parameters needed for laser ablation propulsion modeling.

  11. Cardiac-Specific Overexpression of Catalase Attenuates Lipopolysaccharide-Induced Myocardial Contractile Dysfunction: Role of Autophagy

    Science.gov (United States)

    Turdi, Subat; Han, Xuefeng; Huff, Anna F.; Roe, Nathan D.; Hu, Nan; Gao, Feng; Ren, Jun

    2012-01-01

    Lipopolysaccharide (LPS) from Gram-negative bacteria is a major initiator of sepsis, leading to cardiovascular collapse. Accumulating evidence has indicated a role of reactive oxygen species (ROS) in cardiovascular complication in sepsis. This study was designed to examine the effect of cardiac-specific overexpression of catalase in LPS-induced cardiac contractile dysfunction and the underlying mechanism(s) with a focus on autophagy. Catalase transgenic and wild-type FVB mice were challenged with LPS (6 mg/kg) and cardiac function was evaluated. Levels of oxidative stress, autophagy, apoptosis and protein damage were examined using fluorescence microscopy, Western blot, TUNEL assay, caspase-3 activity and carbonyl formation. Kaplan-Meier curve was constructed for survival following LPS treatment. Our results revealed a lower mortality in catalase mice compared with FVB mice following LPS challenge. LPS injection led to depressed cardiac contractile capacity as evidenced by echocardiography and cardiomyocyte contractile function, the effect of which was ablated by catalase overexpression. LPS treatment induced elevated TNF-α level, autophagy, apoptosis (TUNEL, caspase-3 activation, cleaved caspase-3), production of ROS and O2−, and protein carbonyl formation, the effects of which were significantly attenuated by catalase overexpression. Electron microscopy revealed focal myocardial damage characterized by mitochondrial injury following LPS treatment, which was less severe in catalase mice. Interestingly, LPS-induced cardiomyocyte contractile dysfunction was prevented by antioxidant NAC and the autophagy inhibitor 3-methyladenine. Taken together, our data revealed that catalase protects against LPS-induced cardiac dysfunction and mortality, which may be associated with inhibition of oxidative stress and autophagy. PMID:22902401

  12. Meta-analysis of bipolar radiofrequency endometrial ablation versus thermal balloon endometrial ablation for the treatment of heavy menstrual bleeding.

    Science.gov (United States)

    Zhai, Yan; Zhang, Zihan; Wang, Wei; Zheng, Tingping; Zhang, Huili

    2018-01-01

    Heavy menstrual bleeding is a common problem that can severely affect quality of life. To compare bipolar radiofrequency endometrial ablation and thermal balloon ablation for heavy menstrual bleeding in terms of efficacy and health-related quality of life (HRQoL). Online registries were systematically searched using relevant terms without language restriction from inception to November 24, 2016. Randomized control trials or cohort studies of women with heavy menstrual bleeding comparing the efficacy of two treatments were eligible. Data were extracted. Results were expressed as risk ratios (RRs) or weighted mean differences (WMDs) with 95% confidence intervals (CIs). Six studies involving 901 patients were included. Amenorrhea rate at 12 months was significantly higher after bipolar radiofrequency endometrial ablation than after thermal balloon ablation (RR 2.73, 95% CI 2.00-3.73). However, no difference at 12 months was noted for dysmenorrhea (RR 1.04, 95% CI 0.68-1.58) or treatment failure (RR 0.78, 95% CI 0.38-1.60). The only significant difference for HRQoL outcomes was for change in SAQ pleasure score (12 months: WMD -3.51, 95% CI -5.42 to -1.60). Bipolar radiofrequency endometrial ablation and thermal balloon ablation reduce menstrual loss and improve quality of life. However, bipolar radiofrequency endometrial ablation is more effective in terms of amenorrhea rate and SAQ pleasure. © 2017 International Federation of Gynecology and Obstetrics.

  13. Characterisation of tissue shrinkage during microwave thermal ablation.

    Science.gov (United States)

    Farina, Laura; Weiss, Noam; Nissenbaum, Yitzhak; Cavagnaro, Marta; Lopresto, Vanni; Pinto, Rosanna; Tosoratti, Nevio; Amabile, Claudio; Cassarino, Simone; Goldberg, S Nahum

    2014-11-01

    The aim of this study was to characterise changes in tissue volume during image-guided microwave ablation in order to arrive at a more precise determination of the true ablation zone. The effect of power (20-80 W) and time (1-10 min) on microwave-induced tissue contraction was experimentally evaluated in various-sized cubes of ex vivo liver (10-40 mm ± 2 mm) and muscle (20 and 40 mm ± 2 mm) embedded in agar phantoms (N = 119). Post-ablation linear and volumetric dimensions of the tissue cubes were measured and compared with pre-ablation dimensions. Subsequently, the process of tissue contraction was investigated dynamically during the ablation procedure through real-time X-ray CT scanning. Overall, substantial shrinkage of 52-74% of initial tissue volume was noted. The shrinkage was non-uniform over time and space, with observed asymmetry favouring the radial (23-43 % range) over the longitudinal (21-29%) direction. Algorithmic relationships for the shrinkage as a function of time were demonstrated. Furthermore, the smallest cubes showed more substantial and faster contraction (28-40% after 1 min), with more considerable volumetric shrinkage (>10%) in muscle than in liver tissue. Additionally, CT imaging demonstrated initial expansion of the tissue volume, lasting in some cases up to 3 min during the microwave ablation procedure, prior to the contraction phenomenon. In addition to an asymmetric substantial shrinkage of the ablated tissue volume, an initial expansion phenomenon occurs during MW ablation. Thus, complex modifications of the tissue close to a radiating antenna will likely need to be taken into account for future methods of real-time ablation monitoring.

  14. Ablation by ultrashort laser pulses: Atomistic and thermodynamic analysis of the processes at the ablation threshold

    International Nuclear Information System (INIS)

    Upadhyay, Arun K.; Inogamov, Nail A.; Rethfeld, Baerbel; Urbassek, Herbert M.

    2008-01-01

    Ultrafast laser irradiation of solids may ablate material off the surface. We study this process for thin films using molecular-dynamics simulation and thermodynamic analysis. Both metals and Lennard-Jones (LJ) materials are studied. We find that despite the large difference in thermodynamical properties between these two classes of materials--e.g., for aluminum versus LJ the ratio T c /T tr of critical to triple-point temperature differs by more than a factor of 4--the values of the ablation threshold energy E abl normalized to the cohesion energy, ε abl =E abl /E coh , are surprisingly universal: all are near 0.3 with ±30% scattering. The difference in the ratio T c /T tr means that for metals the melting threshold ε m is low, ε m abl , while for LJ it is high, ε m >ε abl . This thermodynamical consideration gives a simple explanation for the difference between metals and LJ. It explains why despite the universality in ε abl , metals thermomechanically ablate always from the liquid state. This is opposite to LJ materials, which (near threshold) ablate from the solid state. Furthermore, we find that immediately below the ablation threshold, the formation of large voids (cavitation) in the irradiated material leads to a strong temporary expansion on a very slow time scale. This feature is easily distinguished from the acoustic oscillations governing the material response at smaller intensities, on the one hand, and the ablation occurring at larger intensities, on the other hand. This finding allows us to explain the puzzle of huge surface excursions found in experiments at near-threshold laser irradiation

  15. Power Laser Ablation Symposia

    CERN Document Server

    Phipps, Claude

    2007-01-01

    Laser ablation describes the interaction of intense optical fields with matter, in which atoms are selectively driven off by thermal or nonthermal mechanisms. The field of laser ablation physics is advancing so rapidly that its principal results are seen only in specialized journals and conferences. This is the first book that combines the most recent results in this rapidly advancing field with authoritative treatment of laser ablation and its applications, including the physics of high-power laser-matter interaction. Many practical applications exist, ranging from inertial confinement fusion to propulsion of aerostats for pollution monitoring to laser ignition of hypersonic engines to laser cleaning nanoscale contaminants in high-volume computer hard drive manufacture to direct observation of the electronic or dissociative states in atoms and molecules, to studying the properties of materials during 200kbar shocks developed in 200fs. Selecting topics which are representative of such a broad field is difficu...

  16. TEM investigations of laser ablated particles

    International Nuclear Information System (INIS)

    Fliegel, D.; Dundas, S.; Kosler, J.; Klementova, M.

    2009-01-01

    Full text: Laser ablation inductively coupled plasma mass spectrometry suffers from fractionation effects hindering a non matrix matched calibration strategy. Different reasons for elemental fractionation that are related to the laser ablation, the transport and the vaporization in the plasma are discussed. One major question to be addressed linked to the vaporization yield in the ICP is in which of mineralogical phase the different ablated particle sizes enter the plasma. This contribution will investigate particles generated by a 213 nm laser from different samples such as minerals and alloys with respect to their chemical and phase compositions using high resolution TEM. (author)

  17. Pacemaker implantation after catheter ablation for atrial fibrillation.

    Science.gov (United States)

    Deshmukh, Abhishek J; Yao, Xiaoxi; Schilz, Stephanie; Van Houten, Holly; Sangaralingham, Lindsey R; Asirvatham, Samuel J; Friedman, Paul A; Packer, Douglas L; Noseworthy, Peter A

    2016-01-01

    Sinus node dysfunction requiring pacemaker implantation is commonly associated with atrial fibrillation (AF), but may not be clinically apparent until restoration of sinus rhythm with ablation or cardioversion. We sought to determine frequency, time course, and predictors for pacemaker implantation after catheter ablation, and to compare the overall rates to a matched cardioversion cohort. We conducted a retrospective analysis using a large US commercial insurance database and identified 12,158 AF patients who underwent catheter ablation between January 1, 2005 and December 31, 2012. Over an average of 2.4 years of follow-up, 5.6 % of the patients underwent pacemaker implantation. Using the Cox proportional hazards models, we found that risk of risks of pacemaker implantation was associated with older age (50-64 and ≥65 versus pacemaker implantation between ablation patients and propensity score (PS)-matched cardioversion groups (3.5 versus. 4.1 % at 1 year and 8.8 versus 8.3 % at 5 years). Overall, pacemaker implantation occurs in about 1/28 patients within 1 year of catheter ablation. The overall implantation rate decreased between 2005 and 2012. Furthermore, the risk after ablation is similar to cardioversion, suggesting that patients require pacing due to a common underlying electrophysiologic substrate, rather than the ablation itself.

  18. Actual role of radiofrequency ablation of liver metastases

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Philippe L. [Eberhard-Karls-University of Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany)

    2007-08-15

    The liver is, second only to lymph nodes, the most common site for metastatic disease irrespective of the primary tumour. More than 50% of all patients with malignant diseases will develop liver metastases with a significant morbidity and mortality. Although the surgical resection leads to an improved survival in patients with colorectal metastases, only approximately 20% of patients are eligible for surgery. Thermal ablation and especially radiofrequency ablation emerge as an important additional therapy modality for the treatment of liver metastases. RF ablation shows a benefit in life expectancy and may lead in a selected patient group to cure. Percutaneous RF ablation appears safer (versus cryotherapy), easier (versus laser), and more effective (versus ethanol instillation and transarterial chemoembolisation) compared with other minimally invasive procedures. RF ablation can be performed by a percutaneous, laparoscopical or laparotomic approach, and may be potentially combined with chemotherapy and surgery. At present ideal candidates have tumours with a maximum diameter less than 3.5 cm. An untreatable primary tumour or a systemic disease represents contraindications for performing local therapies. Permanent technical improvements of thermal ablation devices and a better integration of thermal ablation in the overall patient care may lead to prognosis improvement in patients with liver metastases. (orig.)

  19. Actual role of radiofrequency ablation of liver metastases

    International Nuclear Information System (INIS)

    Pereira, Philippe L.

    2007-01-01

    The liver is, second only to lymph nodes, the most common site for metastatic disease irrespective of the primary tumour. More than 50% of all patients with malignant diseases will develop liver metastases with a significant morbidity and mortality. Although the surgical resection leads to an improved survival in patients with colorectal metastases, only approximately 20% of patients are eligible for surgery. Thermal ablation and especially radiofrequency ablation emerge as an important additional therapy modality for the treatment of liver metastases. RF ablation shows a benefit in life expectancy and may lead in a selected patient group to cure. Percutaneous RF ablation appears safer (versus cryotherapy), easier (versus laser), and more effective (versus ethanol instillation and transarterial chemoembolisation) compared with other minimally invasive procedures. RF ablation can be performed by a percutaneous, laparoscopical or laparotomic approach, and may be potentially combined with chemotherapy and surgery. At present ideal candidates have tumours with a maximum diameter less than 3.5 cm. An untreatable primary tumour or a systemic disease represents contraindications for performing local therapies. Permanent technical improvements of thermal ablation devices and a better integration of thermal ablation in the overall patient care may lead to prognosis improvement in patients with liver metastases. (orig.)

  20. Plume collimation for laser ablation electrospray ionization mass spectrometry

    Science.gov (United States)

    Vertes, Akos; Stolee, Jessica A.

    2014-09-09

    In various embodiments, a device may generally comprise a capillary having a first end and a second end; a laser to emit energy at a sample in the capillary to ablate the sample and generate an ablation plume in the capillary; an electrospray apparatus to generate an electrospray plume to intercept the ablation plume to produce ions; and a mass spectrometer having an ion transfer inlet to capture the ions. The ablation plume may comprise a collimated ablation plume. The device may comprise a flow cytometer. Methods of making and using the same are also described.

  1. Cardiac-specific overexpression of insulin-like growth factor I (IGF-1) rescues lipopolysaccharide-induced cardiac dysfunction and activation of stress signaling in murine cardiomyocytes.

    Science.gov (United States)

    Zhao, Peng; Turdi, Subat; Dong, Feng; Xiao, Xiaoyan; Su, Guohai; Zhu, Xinglei; Scott, Glenda I; Ren, Jun

    2009-07-01

    Lipopolysaccharide (LPS), a component of the outer membrane of Gram-negative bacteria, plays a key role in cardiac dysfunction in sepsis. Low circulating levels of insulin-like growth factor 1 (IGF-1) are found in sepsis, although the influence of IGF-1 on septic cardiac defect is unknown. This study was designed to examine the impact of IGF-1 on LPS-induced cardiac contractile and intracellular Ca2+ dysfunction, activation of stress signal and endoplasmic reticulum (ER) stress. Mechanical and intracellular Ca2+ properties were examined in cardiomyocytes from Fast Violet B and cardiac-specific IGF-1 overexpression mice treated with or without LPS (4 mg kg(-1), 6 h). Reactive oxygen species (ROS), protein carbonyl formation and apoptosis were measured. Activation of mitogen-activated protein kinase pathways (p38, c-jun N-terminal kinase [JNK] and extracellular signal-related kinase [ERK]), ER stress and apoptotic markers were evaluated using Western blot analysis. Our results revealed decreased peak shortening and maximal velocity of shortening/relengthening and prolonged duration of relengthening in LPS-treated Fast Violet B cardiomyocytes associated with reduced intracellular Ca2+ decay. Accumulation of ROS protein carbonyl and apoptosis were elevated after LPS treatment. Western blot analysis revealed activated p38 and JNK, up-regulated Bax, and the ER stress markers GRP78 and Gadd153 in LPS-treated mouse hearts without any change in ERK and Bcl-2. Total protein expression of p38, JNK, and ERK was unaffected by either LPS or IGF-1. Interestingly, these LPS-induced changes in mechanical and intracellular Ca2+ properties, ROS, protein carbonyl, apoptosis, stress signal activation, and ER stress markers were effectively ablated by IGF-1. In vitro LPS exposure (1 microg mL(-1)) produced cardiomyocyte mechanical dysfunction reminiscent of the in vivo setting, which was alleviated by exogenous IGF-1 (50 nM). These data collectively suggested a beneficial of IGF-1 in

  2. Percutaneous thermal ablation of renal neoplasms; Perkutane Thermoablation von Nierentumoren

    Energy Technology Data Exchange (ETDEWEB)

    Tacke, J. [Inst. fuer Diagnostische und Interventionelle Radiologie/Neuroradiologie, Klinikum Passau (Germany); Mahnken, A.H.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum Aachen (Germany)

    2005-12-15

    Due to modern examination techniques such as multidetector computed tomography and high-field magnetic resonance imaging, the detection rate of renal neoplasms is continually increasing. Even though tumors exceeding 4 cm in diameter rarely metastasize, all renal lesions that are possible neoplasms should be treated. Traditional treatment techniques include radical nephrectomy or nephron-sparing resection, which are increasingly performed laparoscopically. Modern thermal ablation techniques such as hyperthermal techniques like radiofrequency ablation RFA, laser induced thermal ablation LITT, focused ultrasound FUS and microwave therapy MW, as well as hypothermal techniques (cryotherapy) may be a useful treatment option for patients who are unfit for or refuse surgical resection. Cryotherapy is the oldest and best known thermal ablation technique and can be performed laparoscopically or percutaneously. Since subzero temperatures have no antistyptic effect, additional maneuvers must be performed to control bleeding. Percutaneous cryotherapy of renal tumors is a new and interesting method, but experience with it is still limited. Radiofrequency ablation is the most frequently used method. Modern probe design allows volumes between 2 and 5 cm in diameter to be ablated. Due to hyperthermal tract ablation, the procedure is deemed to be safe and has a low complication rate. Although there are no randomized comparative studies to open resection, the preliminary results for renal RFA are promising and show RFA to be superior to other thermal ablation techniques. Clinical success rates are over 90% for both, cryo- and radiofrequency ablation. Whereas laser induced thermal therapy is established in hepatic ablation, experience is minimal with respect to renal application. For lesions of more than 2 cm in diameter, additional cooling catheters are required. MR thermometry offers temperature control during ablation. Microwave ablation is characterized by small ablation volumes

  3. Cardiac disease and arrhythmogenesis: Mechanistic insights from mouse models

    Directory of Open Access Journals (Sweden)

    Lois Choy

    2016-09-01

    Full Text Available The mouse is the second mammalian species, after the human, in which substantial amount of the genomic information has been analyzed. With advances in transgenic technology, mutagenesis is now much easier to carry out in mice. Consequently, an increasing number of transgenic mouse systems have been generated for the study of cardiac arrhythmias in ion channelopathies and cardiomyopathies. Mouse hearts are also amenable to physical manipulation such as coronary artery ligation and transverse aortic constriction to induce heart failure, radiofrequency ablation of the AV node to model complete AV block and even implantation of a miniature pacemaker to induce cardiac dyssynchrony. Last but not least, pharmacological models, despite being simplistic, have enabled us to understand the physiological mechanisms of arrhythmias and evaluate the anti-arrhythmic properties of experimental agents, such as gap junction modulators, that may be exert therapeutic effects in other cardiac diseases. In this article, we examine these in turn, demonstrating that primary inherited arrhythmic syndromes are now recognized to be more complex than abnormality in a particular ion channel, involving alterations in gene expression and structural remodelling. Conversely, in cardiomyopathies and heart failure, mutations in ion channels and proteins have been identified as underlying causes, and electrophysiological remodelling are recognized pathological features. Transgenic techniques causing mutagenesis in mice are extremely powerful in dissecting the relative contributions of different genes play in producing disease phenotypes. Mouse models can serve as useful systems in which to explore how protein defects contribute to arrhythmias and direct future therapy.

  4. Avoiding Complications in Bone and Soft Tissue Ablation

    International Nuclear Information System (INIS)

    Kurup, A. Nicholas; Schmit, Grant D.; Morris, Jonathan M.; Atwell, Thomas D.; Schmitz, John J.; Weisbrod, Adam J.; Woodrum, David A.; Eiken, Patrick W.; Callstrom, Matthew R.

    2017-01-01

    As with percutaneous ablation of tumors in the liver, lungs, and kidneys, ablation of bone and non-visceral soft tissue tumors carries risk, primarily from collateral damage to vital structures in proximity to the target tumor. Certain risks are of particular interest when ablating bone and non-visceral soft tissue tumors, namely neural or skin injury, bowel injury, fracture, and gas embolism from damaged applicators. Ablation of large volume tumors also carries special risk. Many techniques may be employed by the interventional radiologist to minimize complications when treating tumors in the musculoskeletal system. These methods include those to depict, displace, or monitor critical structures. Thus, measures to provide thermoprotection may be active, such as careful ablation applicator placement and use of various displacement techniques, as well as passive, including employment of direct temperature, radiographic, or neurophysiologic monitoring techniques. Cementoplasty should be considered in certain skeletal locations at risk of fracture. Patients treated with large volume tumors should be monitored for renal dysfunction and properly hydrated. Finally, ablation applicators should be cautiously placed in the constrained environment of intact bone.

  5. Avoiding Complications in Bone and Soft Tissue Ablation

    Energy Technology Data Exchange (ETDEWEB)

    Kurup, A. Nicholas, E-mail: kurup.anil@mayo.edu; Schmit, Grant D., E-mail: schmit.grant@mayo.edu; Morris, Jonathan M., E-mail: morris.jonathan@mayo.edu; Atwell, Thomas D., E-mail: atwell.thomas@mayo.edu; Schmitz, John J., E-mail: schmitz.john@mayo.edu; Weisbrod, Adam J., E-mail: weisbrod.adam@mayo.edu; Woodrum, David A., E-mail: woodrum.david@mayo.edu; Eiken, Patrick W., E-mail: eiken.patrick@mayo.edu; Callstrom, Matthew R., E-mail: callstrom.matthew@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2017-02-15

    As with percutaneous ablation of tumors in the liver, lungs, and kidneys, ablation of bone and non-visceral soft tissue tumors carries risk, primarily from collateral damage to vital structures in proximity to the target tumor. Certain risks are of particular interest when ablating bone and non-visceral soft tissue tumors, namely neural or skin injury, bowel injury, fracture, and gas embolism from damaged applicators. Ablation of large volume tumors also carries special risk. Many techniques may be employed by the interventional radiologist to minimize complications when treating tumors in the musculoskeletal system. These methods include those to depict, displace, or monitor critical structures. Thus, measures to provide thermoprotection may be active, such as careful ablation applicator placement and use of various displacement techniques, as well as passive, including employment of direct temperature, radiographic, or neurophysiologic monitoring techniques. Cementoplasty should be considered in certain skeletal locations at risk of fracture. Patients treated with large volume tumors should be monitored for renal dysfunction and properly hydrated. Finally, ablation applicators should be cautiously placed in the constrained environment of intact bone.

  6. Microwave ablation devices for interventional oncology.

    Science.gov (United States)

    Ward, Robert C; Healey, Terrance T; Dupuy, Damian E

    2013-03-01

    Microwave ablation is one of the several options in the ablation armamentarium for the treatment of malignancy, offering several potential benefits when compared with other ablation, radiation, surgical and medical treatment modalities. The basic microwave system consists of the generator, power distribution system and antennas. Often under image (computed tomography or ultrasound) guidance, a needle-like antenna is inserted percutaneously into the tumor, where local microwave electromagnetic radiation is emitted from the probe's active tip, producing frictional tissue heating, capable of causing cell death by coagulation necrosis. Half of the microwave ablation systems use a 915 MHz generator and the other half use a 2450 MHz generator. To date, there are no completed clinical trials comparing microwave devices head-to-head. Prospective comparisons of microwave technology with other treatment alternatives, as well as head-to-head comparison with each microwave device, is needed if this promising field will garner more widespread support and use in the oncology community.

  7. Detection of the Single-Session Complete Ablation Rate by Contrast-Enhanced Ultrasound during Ultrasound-Guided Laser Ablation for Benign Thyroid Nodules: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Shuhua Ma

    2016-01-01

    Full Text Available This study aimed to investigate the single-session complete ablation rate of ultrasound-guided percutaneous laser ablation (LA for benign thyroid nodules. LA was performed in 90 patients with 118 benign thyroid nodules. Contrast-enhanced ultrasound (CEUS was used to evaluate complete nodule ablation one day after ablation. Thyroid nodule volumes, thyroid functions, clinical symptoms and complications were evaluated 1, 3, 6, 12, and 18 months after ablation. Results showed that all benign thyroid nodules successfully underwent LA. The single-session complete ablation rates for nodules with maximum diameters ≤2 cm, 2-3 cm and ≥3 cm were 93.4%, 70.3% and 61.1%, respectively. All nodule volumes significantly decreased than that one day after ablation (P0.05. Three patients had obvious pain during ablation; one (1.1% had recurrent laryngeal nerve injury, but the voice returned to normal within 6 months after treatment. Thus, ultrasound-guided LA can effectively inactivate benign thyroid nodules. LA is a potentially viable minimally invasive treatment that offers good cosmetic effects.

  8. Front-end receiver electronics for a matrix transducer for 3-D transesophageal echocardiography.

    Science.gov (United States)

    Yu, Zili; Blaak, Sandra; Chang, Zu-yao; Yao, Jiajian; Bosch, Johan G; Prins, Christian; Lancée, Charles T; de Jong, Nico; Pertijs, Michiel A P; Meijer, Gerard C M

    2012-07-01

    There is a clear clinical need for creating 3-D images of the heart. One promising technique is the use of transesophageal echocardiography (TEE). To enable 3-D TEE, we are developing a miniature ultrasound probe containing a matrix piezoelectric transducer with more than 2000 elements. Because a gastroscopic tube cannot accommodate the cables needed to connect all transducer elements directly to an imaging system, a major challenge is to locally reduce the number of channels, while maintaining a sufficient signal-to-noise ratio. This can be achieved by using front-end receiver electronics bonded to the transducers to provide appropriate signal conditioning in the tip of the probe. This paper presents the design of such electronics, realizing time-gain compensation (TGC) and micro-beamforming using simple, low-power circuits. Prototypes of TGC amplifiers and micro-beamforming cells have been fabricated in 0.35-μm CMOS technology. These prototype chips have been combined on a printed circuit board (PCB) to form an ultrasound-receiver system capable of reading and combining the signals of three transducer elements. Experimental results show that this design is a suitable candidate for 3-D TEE.

  9. Laser ablation of tumors: current concepts and recent developments

    International Nuclear Information System (INIS)

    Stroszczynski, C.; Gaffke, G.; Gnauck, M.; Ricke, J.; Felix, R.; Puls, R.; Speck, U.; Hosten, N.; Oettle, H.; Hohenberger, P.

    2004-01-01

    Purpose. The purpose of this paper is to present technical innovations and clinical results of percutaneous interventional laser ablation of tumors using new techniques. Methods. Laser ablation was performed in 182 patients (liver tumors: 131, non hepatic tumors - bone, lung, others: 51) after interdisciplinary consensus was obtained. The procedure was done using a combination of imaging modalities (CT/MRI, CT/US) or only closed high field MRI (1.5 T). All patients received an MRI-scan immediately after laser ablation. Results. In 90.9% of the patients with liver tumors, a complete ablation was achieved. Major events occurred in 5.4%. The technical success rate of laser ablation in non-hepatic tumors was high, clinical results differed depending on the treated organ. Conclusions. The treatment of tumors of the liver and other organs up to 5 cm by laser ablation was a safe procedure with a low rate of complications and side effects. Image guidance by MRI is advantageous for precise tumor visualization in all dimensions, therapy monitoring, and control of laser ablation results. (orig.) [de

  10. Cartilage ablation studies using mid-IR free electron laser

    Science.gov (United States)

    Youn, Jong-In; Peavy, George M.; Venugopalan, Vasan

    2005-04-01

    The ablation rate of articular cartilage and fibrocartilage (meniscus), were quantified to examine wavelength and tissue-composition dependence of ablation efficiency for selected mid-infrared wavelengths. The wavelengths tested were 2.9 um (water dominant absorption), 6.1 (protein and water absorption) and 6.45 um (protein dominant absorption) generated by the Free Electron Laser (FEL) at Vanderbilt University. The measurement of tissue mass removal using a microbalance during laser ablation was conducted to determine the ablation rates of cartilage. The technique can be accurate over methods such as profilometer and histology sectioning where tissue surface and the crater morphology may be affected by tissue processing. The ablation efficiency was found to be dependent upon the wavelength. Both articular cartilage and meniscus (fibrocartilage) ablations at 6.1 um were more efficient than those at the other wavelengths evaluated. We observed the lowest ablation efficiency of both types of cartilage with the 6.45 um wavelength, possibly due to the reduction in water absorption at this wavelength in comparison to the other wavelengths that were evaluated.

  11. Cardiac ablation procedures

    Science.gov (United States)

    ... Controlling your high blood pressure Dietary fats explained Fast food tips Heart attack - discharge Heart disease - risk factors ... of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society ...

  12. Thermal Ablation for Benign Thyroid Nodules: Radiofrequency and Laser

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan; Lee, Jeong Hyun [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Valcavi, Roberto [Endocrinology Division and Thyroid Disease Center, Arcispedale Santa Maria Nuova, Reggio Emilia (Italy); Pacella, Claudio M. [Diagnostic Imaging and Interventional Radiology Department, Ospedale Regina Apostolorum, Albano Laziale-Rome (IT); Rhim, Hyun Chul [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Na, Dong Kyu [Human Medical Imaging and Intervention Center, Seoul (Korea, Republic of)

    2011-10-15

    Although ethanol ablation has been successfully used to treat cystic thyroid nodules, this procedure is less effective when the thyroid nodules are solid. Radiofrequency (RF) ablation, a newer procedure used to treat malignant liver tumors, has been valuable in the treatment of benign thyroid nodules regardless of the extent of the solid component. This article reviews the basic physics, techniques, applications, results, and complications of thyroid RF ablation, in comparison to laser ablation.

  13. Dynamic frame selection for in vivo ultrasound temperature estimation during radiofrequency ablation

    International Nuclear Information System (INIS)

    Daniels, Matthew J; Varghese, Tomy

    2010-01-01

    Minimally invasive therapies such as radiofrequency ablation have been developed to treat cancers of the liver, prostate and kidney without invasive surgery. Prior work has demonstrated that ultrasound echo shifts due to temperature changes can be utilized to track the temperature distribution in real time. In this paper, a motion compensation algorithm is evaluated to reduce the impact of cardiac and respiratory motion on ultrasound-based temperature tracking methods. The algorithm dynamically selects the next suitable frame given a start frame (selected during the exhale or expiration phase where extraneous motion is reduced), enabling optimization of the computational time in addition to reducing displacement noise artifacts incurred with the estimation of smaller frame-to-frame displacements at the full frame rate. A region of interest that does not undergo ablation is selected in the first frame and the algorithm searches through subsequent frames to find a similarly located region of interest in subsequent frames, with a high value of the mean normalized cross-correlation coefficient value. In conjunction with dynamic frame selection, two different two-dimensional displacement estimation algorithms namely a block matching and multilevel cross-correlation are compared. The multi-level cross-correlation method incorporates tracking of the lateral tissue expansion in addition to the axial deformation to improve the estimation performance. Our results demonstrate the ability of the proposed motion compensation using dynamic frame selection in conjunction with the two-dimensional multilevel cross-correlation to track the temperature distribution.

  14. Innovative techniques for image-guided ablation of benign thyroid nodules: Combined ethanol and radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye Sun; Baek, Jung Hwan; Choi, Young Jun; Lee, Jeong Hyun [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-06-15

    In the treatment of benign thyroid nodules, ethanol ablation (EA), and radiofrequency ablation (RFA) have been suggested for cystic and solid thyroid nodules, respectively. Although combining these ablation techniques may be effective, no guidelines for or reviews of the combination have been published. Currently, there are three ways of combining EA and RFA: additional RFA is effective for treatment of incompletely resolved symptoms and solid residual portions of a thyroid nodule after EA. Additional EA can be performed for the residual unablated solid portion of a nodule after RFA if it is adjacent to critical structures (e.g., trachea, esophagus, and recurrent laryngeal nerve). In the concomitant procedure, ethanol is injected to control venous oozing after aspiration of cystic fluid prior to RFA of the remaining solid nodule.

  15. Laser ablation in analytical chemistry - A review

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Richard E.; Mao, Xianglei; Liu, Haichen; Gonzalez, Jhanis; Mao, Samuel S.

    2001-10-10

    Laser ablation is becoming a dominant technology for direct solid sampling in analytical chemistry. Laser ablation refers to the process in which an intense burst of energy delivered by a short laser pulse is used to sample (remove a portion of) a material. The advantages of laser ablation chemical analysis include direct characterization of solids, no chemical procedures for dissolution, reduced risk of contamination or sample loss, analysis of very small samples not separable for solution analysis, and determination of spatial distributions of elemental composition. This review describes recent research to understand and utilize laser ablation for direct solid sampling, with emphasis on sample introduction to an inductively coupled plasma (ICP). Current research related to contemporary experimental systems, calibration and optimization, and fractionation is discussed, with a summary of applications in several areas.

  16. Differences in aortic vortex flow pattern between normal and patients with stroke: qualitative and quantitative assessment using transesophageal contrast echocardiography.

    Science.gov (United States)

    Son, Jang-Won; Hong, Geu-Ru; Hong, Woosol; Kim, Minji; Houle, Helene; Vannan, Mani A; Pedrizzetti, Gianni; Chung, Namsik

    2016-06-01

    The flow in the aorta forms a vortex, which is a critical determinant of the flow dynamics in the aorta. Arteriosclerosis can alter the blood flow pattern of the aorta and cause characteristic alterations of the vortex. However, this change in aortic vortex has not yet been studied. This study aimed to characterize aortic vortex flow pattern using transesophageal contrast echocardiography in normal and stroke patients. A total of 85 patients who diagnosed with ischemic stroke and 16 normal controls were recruited for this study. The 16 normal control subjects were designated as the control group, and the 85 ischemic stroke patients were designated as the stroke group. All subjects underwent contrast transesophageal echocardiography (TEE), and particle image velocimetry was used to assess aortic vortex flow. Qualitative and quantitative analyses of vortex flow morphology, location, phasic variation, and pulsatility were undertaken and compared between the groups. In the control group, multiple irregularly-shaped vortices were observed in a peripheral location in the descending thoracic aorta. In contrast, the stroke group had a single, round, merged, and more centrally located aortic vortex flow. In the quantitative analysis of vortex, vortex depth, which represents the location of the major vortex in the aorta, was significantly higher in the control group than in the stroke group (0.599 ± 0.159 vs. 0.522 ± 0.101, respectively, P = 0.013). Vortex relative strength, which is the pulsatility parameter of the vortex itself, was significantly higher in the stroke group than in the control group (0.367 ± 0.148 vs. 0.304 ± 0.087, respectively, P = 0.025). It was feasible to visualize and quantify the characteristic morphology and pulsatility of the aortic vortex flow using contrast TEE, and aortic vortex pattern significantly differed between normal and stroke patients.

  17. Skin pre-ablation and laser assisted microjet injection for deep tissue penetration.

    Science.gov (United States)

    Jang, Hun-Jae; Yeo, Seonggu; Yoh, Jack J

    2017-04-01

    For conventional needless injection, there still remain many unresolved issues such as the potential for cross-contamination, poor reliability of targeted delivery dose, and significantly painstaking procedures. As an alternative, the use of microjets generated with Er:YAG laser for delivering small doses with controlled penetration depths has been reported. In this study, a new system with two stages is evaluated for effective transdermal drug delivery. First, the skin is pre-ablated to eliminate the hard outer layer and second, laser-driven microjet penetrates the relatively weaker and freshly exposed epidermis. Each stage of operation shares a single Er:YAG laser that is suitable for skin ablation as well as for the generation of a microjet. In this study, pig skin is selected for quantification of the injection depth based on the two-stage procedure, namely pre-ablation and microjet injection. The three types of pre-ablation devised here consists of bulk ablation, fractional ablation, and fractional-rotational ablation. The number of laser pulses are 12, 18, and 24 for each ablation type. For fractional-rotational ablation, the fractional beams are rotated by 11.25° at each pulse. The drug permeation in the skin is evaluated using tissue marking dyes. The depth of penetration is quantified by a cross sectional view of the single spot injections. Multi-spot injections are also carried out to control the dose and spread of the drug. The benefits of a pre-ablation procedure prior to the actual microjet injection to the penetration is verified. The four possible combinations of injection are (a) microjet only; (b) bulk ablation and microjet injection; (c) fractional ablation and microjet injection; and (d) fractional-rotational ablation and microjet injection. Accordingly, the total depth increases with injection time for all cases. In particular, the total depth of penetration attained via fractional pre-ablation increased by 8 ∼ 11% and that of fractional

  18. Femtosecond laser ablation and nanoparticle formation in intermetallic NiAl

    Energy Technology Data Exchange (ETDEWEB)

    Jorgensen, David J., E-mail: davidjjorgensen@engr.ucsb.edu; Titus, Michael S.; Pollock, Tresa M.

    2015-10-30

    Highlights: • The single-pulse fs laser ablation threshold of NiAl is 83 mJ/cm{sup 2}. • The transition between low- and high-fluence ablation regimes is 2.8 J/cm{sup 2}. • A bimodal size distribution of nanoparticles is formed with fs laser ablation. • Smaller nanoparticles are enriched in Al during pulsed fs laser ablation. • The target surface is depleted in Al during pulsed fs laser ablation. - Abstract: The ablation behavior of a stoichiometric intermetallic compound β-NiAl subjected to femtosecond laser pulsing in air has been investigated. The single-pulse ablation threshold for NiAl was determined to be 83 ± 4 mJ/cm{sup 2} and the transition to the high-fluence ablation regime occurred at 2.8 ± 0.3 J/cm{sup 2}. Two sizes of nanoparticles consisting of Al, NiAl, Ni{sub 3}Al and NiO were formed and ejected from the target during high-fluence ablation. Chemical analysis revealed that smaller nanoparticles (1–30 nm) tended to be rich in Al while larger nanoparticles (>100 nm) were lean in Al. Ablation in the low-fluence regime maintained this trend. Redeposited material and nanoparticles remaining on the surface after a single 3.7 J/cm{sup 2} pulse, one hundred 1.7 J/cm{sup 2} pulses, or one thousand 250 mJ/cm{sup 2} pulses were enriched in Al relative to the bulk target composition. Further, the surface of the irradiated high-fluence region was depleted in Al indicating that the fs laser ablation removal rate of the intermetallic constituents in this regime does not scale with the individual pure element ablation thresholds.

  19. Measurement of intrahepatic pressure during radiofrequency ablation in porcine liver.

    Science.gov (United States)

    Kawamoto, Chiaki; Yamauchi, Atsushi; Baba, Yoko; Kaneko, Keiko; Yakabi, Koji

    2010-04-01

    To identify the most effective procedures to avoid increased intrahepatic pressure during radiofrequency ablation, we evaluated different ablation methods. Laparotomy was performed in 19 pigs. Intrahepatic pressure was monitored using an invasive blood pressure monitor. Radiofrequency ablation was performed as follows: single-step standard ablation; single-step at 30 W; single-step at 70 W; 4-step at 30 W; 8-step at 30 W; 8-step at 70 W; and cooled-tip. The array was fully deployed in single-step methods. In the multi-step methods, the array was gradually deployed in four or eight steps. With the cooled-tip, ablation was performed by increasing output by 10 W/min, starting at 40 W. Intrahepatic pressure was as follows: single-step standard ablation, 154.5 +/- 30.9 mmHg; single-step at 30 W, 34.2 +/- 20.0 mmHg; single-step at 70 W, 46.7 +/- 24.3 mmHg; 4-step at 30 W, 42.3 +/- 17.9 mmHg; 8-step at 30 W, 24.1 +/- 18.2 mmHg; 8-step at 70 W, 47.5 +/- 31.5 mmHg; and cooled-tip, 114.5 +/- 16.6 mmHg. The radiofrequency ablation-induced area was spherical with single-step standard ablation, 4-step at 30 W, and 8-step at 30 W. Conversely, the ablated area was irregular with single-step at 30 W, single-step at 70 W, and 8-step at 70 W. The ablation time was significantly shorter for the multi-step method than for the single-step method. Increased intrahepatic pressure could be controlled using multi-step methods. From the shapes of the ablation area, 30-W 8-step expansions appear to be most suitable for radiofrequency ablation.

  20. Subcellular analysis by laser ablation electrospray ionization mass spectrometry

    Science.gov (United States)

    Vertes, Akos; Stolee, Jessica A; Shrestha, Bindesh

    2014-12-02

    In various embodiments, a method of laser ablation electrospray ionization mass spectrometry (LAESI-MS) may generally comprise micro-dissecting a cell comprising at least one of a cell wall and a cell membrane to expose at least one subcellular component therein, ablating the at least one subcellular component by an infrared laser pulse to form an ablation plume, intercepting the ablation plume by an electrospray plume to form ions, and detecting the ions by mass spectrometry.

  1. Ablação da fibrilação atrial no Brasil: resultados do registro da Sociedade Brasileira de Arritmias Cardíacas Atrial fibrillation ablation in Brazil: results of the registry of the Brazilian Society of Cardiac Arrhythmias

    Directory of Open Access Journals (Sweden)

    Guilherme Fenelon

    2007-11-01

    Full Text Available FUNDAMENTO: Buscando delinear o perfil da ablação curativa de fibrilação atrial (FA no Brasil, a Sociedade Brasileira de Arritmias Cardíacas (SOBRAC idealizou o Registro Brasileiro de Ablação da FA. OBJETIVO: Descrever os resultados desse registro. MÉTODOS: Foi enviado um formulário aos sócios da SOBRAC, inquirindo sobre os dados de pacientes submetidos a ablação de FA entre setembro de 2005 e novembro de 2006. RESULTADOS: No total, 29 grupos, de 13 Estados, responderam ao formulário. Desses, 22 (76% realizaram ablações de FA. Entre 1998 e 2001, 7 grupos (32% iniciaram ablações de FA e entre 2002 e 2006, 15 grupos (68%. De 1998 a 2006, 2.374 pacientes foram submetidos a ablação, sendo 755 (32% no período do registro. A maioria (70% era do sexo masculino e 89% apresentavam FA paroxística ou persistente. Métodos auxiliares de imagem (ecocardiografia intracardíaca e mapeamento eletroanatômico foram utilizados por 9 grupos (41%. Durante seguimento médio de cinco meses, o sucesso total foi de 82% e o sucesso sem uso de antiarrítmicos foi de 57%. Contudo, 35% dos pacientes necessitaram de dois ou mais procedimentos. Houve 111 complicações (14,7% e 2 óbitos (0,26%. CONCLUSÃO: A ablação curativa de FA vem crescendo significativamente em nosso País, com taxas de sucesso comparáveis às internacionais, mas comumente há necessidade de mais de um procedimento. Apesar dos resultados promissores, a ablação de FA ainda acarreta morbidade significativa. Métodos auxiliares de imagem têm sido cada vez mais utilizados, visando a aumentar a eficácia e a segurança do procedimento. Esses achados devem ser considerados pelos órgãos pagadores públicos e privados.BACKGROUND: Aiming to define the profile of curative atrial fibrillation (AF ablation in Brazil, the Brazilian Cardiac Arrhythmia Society [Sociedade Brasileira de Arritmias Cardíacas] (SOBRAC created the Brazilian Registry of AF Ablation [Registro Brasileiro de Abla

  2. Mucosal ablation in Barrett's esophagus.

    Science.gov (United States)

    Walker, S J; Selvasekar, C R; Birbeck, N

    2002-01-01

    Barrett's esophagus is a prevalent, premalignant condition affecting the gastroesophageal junction and distal esophagus. Ablation plus antireflux therapy has recently been advocated to prevent the development of adenocarcinoma or to treat those unfit or unwilling to undergo esophagectomy. The present article, based on a search of Medline/ISI databases and cross-referencing of relevant articles, reviews the literature on this subject. A number of techniques have been used to remove the affected mucosa, including laser, electrocoagulation, argon plasma coagulation and photodynamic therapy but, as yet, none has been shown to be superior. Depending on the method used, ablation results in complete removal of Barrett's esophagus in approximately one third of patients and a partial response in nearly two-thirds. The resultant squamous mucosa is apparently 'normal' but may regress. To promote and maintain regeneration, antireflux therapy must be sufficient to reduce repetitive injury to the esophageal mucosa. Whether ablation reduces the cancer risk or delays its occurrence is unknown, though recent data suggests benefit. Complications are infrequent and usually mild. Regular follow-up endoscopy and deep biopsies continue to be necessary. Careful data from much larger populations with long-term follow-up is required before ablation reaches the stage of broad clinical application.

  3. Photoactive dye enhanced tissue ablation for endoscopic laser prostatectomy

    Science.gov (United States)

    Ahn, Minwoo; Nguyen, Trung Hau; Nguyen, Van Phuc; Oh, Junghwan; Kang, Hyun Wook

    2015-02-01

    Laser light has been widely used as a surgical tool to treat benign prostate hyperplasia with high laser power. The purpose of this study was to validate the feasibility of photoactive dye injection to enhance light absorption and eventually to facilitate tissue ablation with low laser power. The experiment was implemented on chicken breast due to minimal optical absorption Amaranth (AR), black dye (BD), hemoglobin powder (HP), and endoscopic marker (EM), were selected and tested in vitro with a customized 532-nm laser system with radiant exposure ranging from 0.9 to 3.9 J/cm2. Light absorbance and ablation threshold were measured with UV-VIS spectrometer and Probit analysis, respectively, and compared to feature the function of the injected dyes. Ablation performance with dye-injection was evaluated in light of radiant exposure, dye concentration, and number of injection. Higher light absorption by injected dyes led to lower ablation threshold as well as more efficient tissue removal in the order of AR, BD, HP, and EM. Regardless of the injected dyes, ablation efficiency principally increased with input parameter. Among the dyes, AR created the highest ablation rate of 44.2+/-0.2 μm/pulse due to higher absorbance and lower ablation threshold. Preliminary tests on canine prostate with a hydraulic injection system demonstrated that 80 W with dye injection yielded comparable ablation efficiency to 120 W with no injection, indicating 33 % reduced laser power with almost equivalent performance. In-depth comprehension on photoactive dye-enhanced tissue ablation can help accomplish efficient and safe laser treatment for BPH with low power application.

  4. Similarities and differences in ablative and non-ablative iron oxide nanoparticle hyperthermia cancer treatment

    Science.gov (United States)

    Petryk, Alicia A.; Misra, Adwiteeya; Kastner, Elliot J.; Mazur, Courtney M.; Petryk, James D.; Hoopes, P. Jack

    2015-03-01

    The use of hyperthermia to treat cancer is well studied and has utilized numerous delivery techniques, including microwaves, radio frequency, focused ultrasound, induction heating, infrared radiation, warmed perfusion liquids (combined with chemotherapy), and recently, metallic nanoparticles (NP) activated by near infrared radiation (NIR) and alternating magnetic field (AMF) based platforms. It has been demonstrated by many research groups that ablative temperatures and cytotoxicity can be produced with locally NP-based hyperthermia. Such ablative NP techniques have demonstrated the potential for success. Much attention has also been given to the fact that NP may be administered systemically, resulting in a broader cancer therapy approach, a lower level of tumor NP content and a different type of NP cancer therapy (most likely in the adjuvant setting). To use NP based hyperthermia successfully as a cancer treatment, the technique and its goal must be understood and utilized in the appropriate clinical context. The parameters include, but are not limited to, NP access to the tumor (large vs. small quantity), cancer cell-specific targeting, drug carrying capacity, potential as an ionizing radiation sensitizer, and the material properties (magnetic characteristics, size and charge). In addition to their potential for cytotoxicity, the material properties of the NP must also be optimized for imaging, detection and direction. In this paper we will discuss the differences between, and potential applications for, ablative and non-ablative magnetic nanoparticle hyperthermia.

  5. Nanoparticle fabrication of hydroxyapatite by laser ablation in water

    International Nuclear Information System (INIS)

    Musaev, O. R.; Wieliczka, D. M.; Wrobel, J. M.; Kruger, M. B.; Dusevich, V.

    2008-01-01

    Synthetic polycrystalline hydroxyapatite was ablated in water with 337 nm radiation from a UV nitrogen pulsed laser. According to transmission electron microscopy micrographs, the ablated particles were approximately spherical and had a size of ∼80 nm. Raman spectroscopic analysis demonstrated that particles had the same structure as the original crystal. X-ray photoelectron spectroscopy showed that the surface chemical composition was close to that of the original material. The characteristics of the ablated particles and estimations of the temperature rise of the hydroxyapatite surface under laser irradiation are consistent with the mechanism of explosive boiling being responsible for ablation. The experimental observations offer the basis for preparation of hydroxyapatite nanoparticles by laser ablation in water

  6. A thermal model for nanosecond pulsed laser ablation of aluminum

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    2017-07-01

    Full Text Available In order to simulate the nanosecond pulsed laser ablation of aluminum, a novel model was presented for the target ablation and plume expansion. The simulation of the target ablation was based on one-dimensional heat conduction, taking into account temperature dependent material properties, phase transition, dielectric transition and phase explosion. While the simulation of the plume expansion was based on one-dimensional gas-dynamical equation, taking into account ionization, plume absorption and shielding. By coupling the calculations of the target ablation and plume expansion, the characteristics of the target and plume were obtained. And the calculated results were in good agreement with the experimental data, in terms of ablation threshold and depth within the fluence range of the tested laser. Subsequently, investigations were carried out to analyze the mechanisms of nanosecond pulsed laser ablation. The calculated results showed that the maximum surface temperature remained at about 90% of the critical temperature (0.9Tc due to phase explosion. Moreover, the plume shielding has significant effects on the laser ablation, and the plume shielding proportion increase as the laser fluence increasing. The ambient pressure belows 100 Pa is more suitable for laser ablation, which can obtained larger ablation depth.

  7. Cardiac regeneration therapy: connections to cardiac physiology.

    Science.gov (United States)

    Takehara, Naofumi; Matsubara, Hiroaki

    2011-12-01

    Without heart transplantation, a large number of patients with failing hearts worldwide face poor outcomes. By means of cardiomyocyte regeneration, cardiac regeneration therapy is emerging with great promise as a means for restoring loss of cardiac function. However, the limited success of clinical trials using bone marrow-derived cells and myoblasts with heterogeneous constituents, transplanted at a wide range of cell doses, has led to disagreement on the efficacy of cell therapy. It is therefore essential to reevaluate the evidence for the efficacy of cell-based cardiac regeneration therapy, focusing on targets, materials, and methodologies. Meanwhile, the revolutionary innovation of cardiac regeneration therapy is sorely needed to help the millions of people who suffer heart failure from acquired loss of cardiomyocytes. Cardiac regeneration has been used only in limited species or as a developing process in the rodent heart; now, the possibility of cardiomyocyte turnover in the human heart is being revisited. In the pursuit of this concept, the use of cardiac stem/progenitor stem cells in the cardiac niche must be focused to usher in a second era of cardiac regeneration therapy for the severely injured heart. In addition, tissue engineering and cellular reprogramming will advance the next era of treatment that will enable current cell-based therapy to progress to "real" cardiac regeneration therapy. Although many barriers remain, the prevention of refractory heart failure through cardiac regeneration is now becoming a realistic possibility.

  8. Using Target Ablation for Ion Beam Quality Improvement

    International Nuclear Information System (INIS)

    Zhao Shuan; Chen Jia-Er; Lin Chen; Ma Wen-Jun; Yan Xue-Qing; Wang Jun-Jie

    2016-01-01

    During the laser foil interaction, the output ion beam quality including the energy spread and beam divergence can be improved by the target ablation, due to the direct laser acceleration (DLA) electrons generated in the ablation plasma. The acceleration field established at the target rear by these electrons, which is highly directional and triangle-envelope, is helpful for the beam quality. With the help of the target ablation, both the beam divergence and energy spread will be reduced. If the ablation is more sufficient, the impact of DLA-electron-caused field will be strengthened, and the beam quality will be better, confirmed by the particle-in-cell simulation. (paper)

  9. Radiofrequency ablation with epinephrine injection: in vivo study in normal pig livers

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Jung; Lee, Dong Hoo; Lim, Joo Won; Ko, Young Tae; Kim, Youn Wha; Choi, Bong Keun [Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2007-07-15

    We wanted to evaluate whether epinephrine injection prior to radiofrequency (RF) ablation can increase the extent of thermally mediated coagulation in vivo normal pig liver tissue. Eighteen RF ablation zones were created in six pigs using a 17-gauge internally cooled electrode under ultrasound guidance. Three RF ablation zones were created in each pig under three conditions: RF ablation alone, RF ablation after the injection of 3 mL of normal saline, and RF ablation after the injection of 3 mL of epinephrine (1:10,000 solution). After the RF ablation, we measured the short and long diameters of the white zones in the gross specimens. Three of the RF ablations were technically unsuccessful; therefore, measurement of white zone was finally done in 15 RF ablation zones. The mean short and long diameters of the white zone of the RF ablation after epinephrine injection (17.2 mm {+-} 1.8 and 20.8 mm {+-} 3.7, respectively) were larger than those of RF ablation only (10 mm {+-} 1.2 and 12.2 mm {+-} 1.1, respectively) and RF ablation after normal saline injection (12.8 mm {+-} 1.5 and 15.6 mm {+-} 2.5, respectively) ({rho} < .05). RF ablation with epinephrine injection can increase the diameter of the RF ablation zone in normal pig liver tissue.

  10. New mitigation schemes of the ablative Rayleigh-Taylor instability

    International Nuclear Information System (INIS)

    Azechi, H.; Shiraga, H.; Nakai, M.; Shigemori, K.; Fujioka, S.; Sakaiya, T.; Tamari, Y.; Ohtani, K.; Watari, T.; Murakami, M.; Sunahara, A.; Nagatomo, H.; Nishihara, K.; Miyanaga, N.; Izawa, Y.; Ohnishi, N.

    2005-01-01

    The Rayleigh-Taylor (RT) instability with material ablation through the unstable interface is the key physics that determines success or failure of inertial fusion energy (IFE) generation, as the RT instability potentially quenches ignition and burn by disintegrating the IFE target. We present two suppression schemes of the RT growth without significant degradation of the target density. The first scheme is to generate double ablation structure in high-Z doped plastic targets. In addition to the electron ablation surface, a new ablation surface is created by x-ray radiation from the high-Z ions. Contrary to the previous thought, the electron ablation surface is almost completely stabilized by extremely high flow velocity. On the other hand, the RT instability on the radiative ablation surface is significantly moderated. The second is to enhance the nonlocal nature of the electron heat transport by illuminating the target with long wavelength laser light, whereas the high ablation pressure is generated by irradiating short wavelength laser light. The significant suppression of the RT instability may increase the possibility of impact ignition which uses a high velocity fuel colliding with a preformed main fuel. (author)

  11. Percutaneous laser ablation of benign and malignant thyroid nodules.

    Science.gov (United States)

    Papini, Enrico; Bizzarri, Giancarlo; Pacella, Claudio M

    2008-10-01

    Percutaneous image-guided procedures, largely based on thermal ablation, are at present under investigation for achieving a nonsurgical targeted cytoreduction in benign and malignant thyroid lesions. In several uncontrolled clinical trials and in two randomized clinical trials, laser ablation has demonstrated a good efficacy and safety for the shrinkage of benign cold thyroid nodules. In hyperfunctioning nodules, laser ablation induced a nearly 50% volume reduction with a variable frequency of normalization of thyroid-stimulating hormone levels. Laser ablation has been tested for the palliative treatment of poorly differentiated thyroid carcinomas, local recurrences or distant metastases. Laser ablation therapy is indicated for the shrinkage of benign cold nodules in patients with local pressure symptoms who are at high surgical risk. The treatment should be performed only by well trained operators and after a careful cytological evaluation. Laser ablation does not seem to be consistently effective in the long-term control of hyperfunctioning thyroid nodules and is not an alternative treatment to 131I therapy. Laser ablation may be considered for the cytoreduction of tumor tissue prior to external radiation therapy or chemotherapy of local or distant recurrences of thyroid malignancy that are not amenable to surgical or radioiodine treatment.

  12. Cardiac-specific overexpression of catalase attenuates lipopolysaccharide-induced myocardial contractile dysfunction: role of autophagy.

    Science.gov (United States)

    Turdi, Subat; Han, Xuefeng; Huff, Anna F; Roe, Nathan D; Hu, Nan; Gao, Feng; Ren, Jun

    2012-09-15

    Lipopolysaccharide (LPS) from gram-negative bacteria is a major initiator of sepsis, leading to cardiovascular collapse. Accumulating evidence has indicated a role of reactive oxygen species (ROS) in cardiovascular complications in sepsis. This study was designed to examine the effect of cardiac-specific overexpression of catalase in LPS-induced cardiac contractile dysfunction and the underlying mechanism(s) with a focus on autophagy. Catalase transgenic and wild-type FVB mice were challenged with LPS (6 mg/kg) and cardiac function was evaluated. Levels of oxidative stress, autophagy, apoptosis, and protein damage were examined using fluorescence microscopy, Western blot, TUNEL assay, caspase-3 activity, and carbonyl formation. A Kaplan-Meier curve was constructed for survival after LPS treatment. Our results revealed a lower mortality in catalase mice compared with FVB mice after LPS challenge. LPS injection led to depressed cardiac contractile capacity as evidenced by echocardiography and cardiomyocyte contractile function, the effect of which was ablated by catalase overexpression. LPS treatment induced elevated TNF-α level, autophagy, apoptosis (TUNEL, caspase-3 activation, cleaved caspase-3), production of ROS and O(2)(-), and protein carbonyl formation, the effects of which were significantly attenuated by catalase overexpression. Electron microscopy revealed focal myocardial damage characterized by mitochondrial injury after LPS treatment, which was less severe in catalase mice. Interestingly, LPS-induced cardiomyocyte contractile dysfunction was prevented by the antioxidant N-acetylcysteine and the autophagy inhibitor 3-methyladenine. Taken together, our data revealed that catalase protects against LPS-induced cardiac dysfunction and mortality, which may be associated with inhibition of oxidative stress and autophagy. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. No-touch radiofrequency ablation: A comparison of switching bipolar and switching monopolar ablation in Ex Vivo bovine liver

    International Nuclear Information System (INIS)

    Chang, Won; Lee, Jeong Min; Lee, Sang Min; Hank, Joon Koo

    2017-01-01

    To evaluate the feasibility, efficiency, and safety of no-touch switching bipolar (SB) and switching monopolar (SM) radiofrequency ablation (RFA) using ex vivo bovine livers. A pork loin cube was inserted as a tumor mimicker in the bovine liver block; RFA was performed using the no-touch technique in the SM (group A1; 10 minutes, n = 10, group A2; 15 minutes, n = 10) and SB (group B; 10 minutes, n = 10) modes. The groups were compared based on the creation of confluent necrosis with sufficient safety margins, the dimensions, and distance between the electrode and ablation zone margin (DEM). To evaluate safety, small bowel loops were placed above the liver surface and 30 additional ablations were performed in the same groups. Confluent necroses with sufficient safety margins were created in all specimens. SM RFA created significantly larger volumes of ablation compared to SB RFA (all p < 0.001). The DEM of group B was significantly lower than those of groups A1 and A2 (all p < 0.001). Although thermal injury to the small bowel was noted in 90%, 100%, and 30% of the cases in groups A1, A2, and B, respectively, full depth injury was noted only in 60% of group A2 cases. The no-touch RFA technique is feasible in both the SB and SM modes; however, SB RFA appears to be more advantageous compared to SM RFA in the creation of an ablation zone while avoiding the unnecessary creation of an adjacent parenchymal ablation zone or adjacent small bowel injuries

  14. No-touch radiofrequency ablation: A comparison of switching bipolar and switching monopolar ablation in Ex Vivo bovine liver

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Won; Lee, Jeong Min; Lee, Sang Min; Hank, Joon Koo [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-04-15

    To evaluate the feasibility, efficiency, and safety of no-touch switching bipolar (SB) and switching monopolar (SM) radiofrequency ablation (RFA) using ex vivo bovine livers. A pork loin cube was inserted as a tumor mimicker in the bovine liver block; RFA was performed using the no-touch technique in the SM (group A1; 10 minutes, n = 10, group A2; 15 minutes, n = 10) and SB (group B; 10 minutes, n = 10) modes. The groups were compared based on the creation of confluent necrosis with sufficient safety margins, the dimensions, and distance between the electrode and ablation zone margin (DEM). To evaluate safety, small bowel loops were placed above the liver surface and 30 additional ablations were performed in the same groups. Confluent necroses with sufficient safety margins were created in all specimens. SM RFA created significantly larger volumes of ablation compared to SB RFA (all p < 0.001). The DEM of group B was significantly lower than those of groups A1 and A2 (all p < 0.001). Although thermal injury to the small bowel was noted in 90%, 100%, and 30% of the cases in groups A1, A2, and B, respectively, full depth injury was noted only in 60% of group A2 cases. The no-touch RFA technique is feasible in both the SB and SM modes; however, SB RFA appears to be more advantageous compared to SM RFA in the creation of an ablation zone while avoiding the unnecessary creation of an adjacent parenchymal ablation zone or adjacent small bowel injuries.

  15. Theoretical analyses of the refractive implications of transepithelial PRK ablations.

    Science.gov (United States)

    Arba Mosquera, Samuel; Awwad, Shady T

    2013-07-01

    To analyse the refractive implications of single-step, transepithelial photorefractive keratectomy (TransPRK) ablations. A simulation for quantifying the refractive implications of TransPRK ablations has been developed. The simulation includes a simple modelling of corneal epithelial profiles, epithelial ablation profiles as well as refractive ablation profiles, and allows the analytical quantification of the refractive implications of TransPRK in terms of wasted tissue, achieved optical zone (OZ) and induced refractive error. Wasted tissue occurs whenever the actual corneal epithelial profile is thinner than the applied epithelial ablation profile, achieved OZ is reduced whenever the actual corneal epithelial profile is thicker than the applied epithelial ablation profile and additional refractive errors are induced whenever the actual difference centre-to-periphery in the corneal epithelial profile deviates from the difference in the applied epithelial ablation profile. The refractive implications of TransPRK ablations can be quantified using simple theoretical simulations. These implications can be wasted tissue (∼14 µm, if the corneal epithelial profile is thinner than the ablated one), reduced OZ (if the corneal epithelial profile is thicker than ablated one, very severe for low corrections) and additional refractive errors (∼0.66 D, if the centre-to-periphery progression of the corneal epithelial profile deviates from the progression of the ablated one). When TransPRK profiles are applied to normal, not previously treated, non-pathologic corneas, no specific refractive implications associated to the transepithelial profile can be anticipated; TransPRK would provide refractive outcomes equal to those of standard PRK. Adjustments for the planned OZ and, in the event of retreatments, for the target sphere can be easily derived.

  16. Laser ablation comparison by picosecond pulses train and nanosecond pulse

    Science.gov (United States)

    Lednev, V. N.; Filippov, M. N.; Bunkin, A. F.; Pershin, S. M.

    2015-12-01

    A comparison of laser ablation by a train of picosecond pulses and nanosecond pulses revealed a difference in laser craters, ablation thresholds, plasma sizes and spectral line intensities. Laser ablation with a train of picosecond pulses resulted in improved crater quality while ablated mass decreased up to 30%. A reduction in laser plasma dimensions for picosecond train ablation was observed while the intensity of atomic/ionic lines in the plasma spectra was greater by a factor of 2-4 indicating an improved excitation and atomization in the plasma.

  17. Imaging in percutaneous ablation for atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Maksimovic, Ruzica [Erasmus Medical Center, Department of Radiology, GD Rotterdam (Netherlands); Institute for Cardiovascular Diseases of the University Medical Center, Belgrade (Czechoslovakia); Dill, Thorsten [Kerckhoff-Heart Center, Department of Cardiology, Bad Nauheim (Germany); Ristic, Arsen D.; Seferovic, Petar M. [Institute for Cardiovascular Diseases of the University Medical Center, Belgrade (Czechoslovakia)

    2006-11-15

    Percutaneous ablation for electrical disconnection of the arrhythmogenic foci using various forms of energy has become a well-established technique for treating atrial fibrillation (AF). Success rate in preventing recurrence of AF episodes is high although associated with a significant incidence of pulmonary vein (PV) stenosis and other rare complications. Clinical workup of AF patients includes imaging before and after ablative treatment using different noninvasive and invasive techniques such as conventional angiography, transoesophageal and intracardiac echocardiography, computed tomography (CT) and magnetic resonance imaging (MRI), which offer different information with variable diagnostic accuracy. Evaluation before percutaneous ablation involves assessment of PVs (PV pattern, branching pattern, orientation and ostial size) to facilitate position and size of catheters and reduce procedure time as well as examining the left atrium (presence of thrombi, dimensions and volumes). Imaging after the percutaneous ablation is important for assessment of overall success of the procedure and revealing potential complications. Therefore, imaging methods enable depiction of PVs and the anatomy of surrounding structures essential for preprocedural management and early detection of PV stenosis and other ablation-related procedures, as well as long-term follow-up of these patients. (orig.)

  18. Imaging in percutaneous ablation for atrial fibrillation

    International Nuclear Information System (INIS)

    Maksimovic, Ruzica; Dill, Thorsten; Ristic, Arsen D.; Seferovic, Petar M.

    2006-01-01

    Percutaneous ablation for electrical disconnection of the arrhythmogenic foci using various forms of energy has become a well-established technique for treating atrial fibrillation (AF). Success rate in preventing recurrence of AF episodes is high although associated with a significant incidence of pulmonary vein (PV) stenosis and other rare complications. Clinical workup of AF patients includes imaging before and after ablative treatment using different noninvasive and invasive techniques such as conventional angiography, transoesophageal and intracardiac echocardiography, computed tomography (CT) and magnetic resonance imaging (MRI), which offer different information with variable diagnostic accuracy. Evaluation before percutaneous ablation involves assessment of PVs (PV pattern, branching pattern, orientation and ostial size) to facilitate position and size of catheters and reduce procedure time as well as examining the left atrium (presence of thrombi, dimensions and volumes). Imaging after the percutaneous ablation is important for assessment of overall success of the procedure and revealing potential complications. Therefore, imaging methods enable depiction of PVs and the anatomy of surrounding structures essential for preprocedural management and early detection of PV stenosis and other ablation-related procedures, as well as long-term follow-up of these patients. (orig.)

  19. Effects of pressure rise on cw laser ablation of tissue

    Science.gov (United States)

    LeCarpentier, Gerald L.; Motamedi, Massoud; Welch, Ashley J.

    1991-06-01

    The objectives of this research were to identify mechanisms responsible for the initiation of continuous wave (cw) laser ablation of tissue and investigate the role of pressure in the ablation process. Porcine aorta samples were irradiated in a chamber pressurized from 1 X 10-4 to 12 atmospheres absolute pressure. Acrylic and Zn-Se windows in the experimental pressure chamber allowed video and infrared cameras to simultaneously record mechanical and thermal events associated with cw argon laser ablation of these samples. Video and thermal images of tissue slabs documented the explosive nature of cw laser ablation of soft biological media and revealed similar ablation threshold temperatures and ablation onset times under different environmental pressures; however, more violent initiation explosions with decreasing environmental pressures were observed. These results suggest that ablation initiates with thermal alterations in the mechanical strength of the tissue and proceeds with an explosion induced by the presence superheated liquid within the tissue.

  20. Pulsed Tm:YAG laser ablation of knee joint tissues

    Science.gov (United States)

    Shi, Wei-Qiang; Vari, Sandor G.; Duffy, J. T.; Miller, J. M.; Weiss, Andrew B.; Fishbein, Michael C.; Grundfest, Warren S.

    1992-06-01

    We investigated the effect of a free-running 2.01 micron pulsed Tm:YAG laser on bovine knee joint tissues. Ablation rates of fresh fibrocartilage, hyaline cartilage, and bone were measured in saline as a function of laser fluence (160 - 640 J/cm2) and fiber core size (400 and 600 microns). All tissues could be effectively ablated and the ablation rate increased linearly with the increasing fluence. Use of fibers of different core sizes, while maintaining constant energy fluence, did not result in significant difference in ablation rate. Histology analyses of the ablated tissue samples reveal average Tm:YAG radiation induced thermal damage (denatunalization) zones ranging between 130 and 540 microns, depending on the laser parameters and the tissue type.

  1. Pulsed-laser ablation of co-deposits on JT-60 graphite tile

    International Nuclear Information System (INIS)

    Sakawa, Youichi; Watanabe, Daisuke; Shibahara, Takahiro; Sugiyama, Kazuyoshi; Tanabe, Tetsuo

    2007-01-01

    Pulsed laser ablation of the co-deposits on a JT-60 open-divertor tile using the fourth harmonic of a 20 ps-Nd: YAG laser has been investigated. With increasing the laser intensity, three regions, non-ablation region (NAR), weak-ablation region (WAR), and strong-ablation region (SAR) were distinguished. Transition from NAR to WAR and WAR to SAR occurred at the threshold laser intensity for laser ablation and that for strong ionization of carbon atoms, respectively. The ablation accompanied desorption of H 2 and C 2 H 2 , with minor contribution of other hydrocarbons, while production of H 2 O was small. In NAR and WAR the number of the hydrogen desorbed by the laser irradiation was less than that of hydrogen retained in the ablated volume, while in SAR it was much larger, owing to thermal desorption of hydrogen gas from the region surrounding the ablated volume. For the ablative removal of hydrogen isotopes, SAR is more desirable because of higher removal efficiency and less production of hydrocarbons

  2. Pulsed-laser ablation of co-deposits on JT-60 graphite tile

    Energy Technology Data Exchange (ETDEWEB)

    Sakawa, Youichi [Institute of Laser Engineering, Osaka University, Yamadaoka, Suita, Osaka 565-0871 (Japan)]. E-mail: sakawa-y@ile.osaka-u.ac.jp; Watanabe, Daisuke [Graduate School of Engineering, Nagoya University, Chikusa-ku, Nagoya, Aichi 464-8603 (Japan); Shibahara, Takahiro [Graduate School of Engineering, Nagoya University, Chikusa-ku, Nagoya, Aichi 464-8603 (Japan); Sugiyama, Kazuyoshi [Interdisciplinary School of Engineering Science, Kyushu University, Fukuoka, Fukuoka 812-8581 (Japan); Tanabe, Tetsuo [Interdisciplinary School of Engineering Science, Kyushu University, Fukuoka, Fukuoka 812-8581 (Japan)

    2007-08-01

    Pulsed laser ablation of the co-deposits on a JT-60 open-divertor tile using the fourth harmonic of a 20 ps-Nd: YAG laser has been investigated. With increasing the laser intensity, three regions, non-ablation region (NAR), weak-ablation region (WAR), and strong-ablation region (SAR) were distinguished. Transition from NAR to WAR and WAR to SAR occurred at the threshold laser intensity for laser ablation and that for strong ionization of carbon atoms, respectively. The ablation accompanied desorption of H{sub 2} and C{sub 2}H{sub 2}, with minor contribution of other hydrocarbons, while production of H{sub 2}O was small. In NAR and WAR the number of the hydrogen desorbed by the laser irradiation was less than that of hydrogen retained in the ablated volume, while in SAR it was much larger, owing to thermal desorption of hydrogen gas from the region surrounding the ablated volume. For the ablative removal of hydrogen isotopes, SAR is more desirable because of higher removal efficiency and less production of hydrocarbons.

  3. Direct-drive–ignition designs with mid-Z ablators

    Energy Technology Data Exchange (ETDEWEB)

    Lafon, M.; Betti, R. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623 (United States); Laboratory for Laser Energetics and Fusion Science Center, University of Rochester, 250 East River Road, Rochester, New York 14623 (United States); Anderson, K. S.; Collins, T. J. B.; Epstein, R.; McKenty, P. W.; Myatt, J. F.; Shvydky, A.; Skupsky, S. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623 (United States)

    2015-03-15

    Achieving thermonuclear ignition using direct laser illumination relies on the capability to accelerate spherical shells to high implosion velocities while maintaining shell integrity. Ablator materials of moderate atomic number Z reduce the detrimental effects of laser–plasma instabilities in direct-drive implosions. To validate the physics of moderate-Z ablator materials for ignition target designs on the National Ignition Facility (NIF), hydro-equivalent targets are designed using pure plastic (CH), high-density carbon, and glass (SiO{sub 2}) ablators. The hydrodynamic stability of these targets is investigated through two-dimensional (2D) single-mode and multimode simulations. The overall stability of these targets to laser-imprint perturbations and low-mode asymmetries makes it possible to design high-gain targets. Designs using polar-drive illumination are developed within the NIF laser system specifications. Mid-Z ablator targets are an attractive candidate for direct-drive ignition since they present better overall performance than plastic ablator targets through reduced laser–plasma instabilities and a similar hydrodynamic stability.

  4. Computed Tomography Assessment of Ablation Zone Enhancement in Patients With Early-Stage Lung Cancer After Stereotactic Ablative Radiotherapy.

    Science.gov (United States)

    Moore, William; Chaya, Yair; Chaudhry, Ammar; Depasquale, Britney; Glass, Samantha; Lee, Susan; Shin, James; Mikhail, George; Bhattacharji, Priya; Kim, Bong; Bilfinger, Thomas

    2015-01-01

    Stereotactic ablative radiotherapy (SABR) offers a curative treatment for lung cancer in patients who are marginal surgical candidates. However, unlike traditional surgery the lung cancer remains in place after treatment. Thus, imaging follow-up for evaluation of recurrence is of paramount importance. In this retrospective designed Institutional Review Board-approved study, follow-up contrast-enhanced computed tomography (CT) exams were performed on sixty one patients to evaluate enhancement pattern in the ablation zone at 1, 3, 6, and 12 months after SABR. Eleven patients had recurrence within the ablation zone after SABR. The postcontrast enhancement in the recurrence group showed a washin and washout phenomenon, whereas the radiation-induced lung injury group showed continuous enhancement suggesting an inflammatory process. The textural feature of the ablation zone of enhancement and perfusion as demonstrated in computed tomography nodule enhancement may allow early differentiation of recurrence from radiation-induced lung injury in patients' status after SABR or primary lung cancer.

  5. Combination acetabular radiofrequency ablation and cementoplasty using a navigational radiofrequency ablation device and ultrahigh viscosity cement: technical note.

    Science.gov (United States)

    Wallace, Adam N; Huang, Ambrose J; Vaswani, Devin; Chang, Randy O; Jennings, Jack W

    2016-03-01

    Percutaneous radiofrequency ablation and cementoplasty is an alternative palliative therapy for painful metastases involving axial load-bearing bones. This technical report describes the use of a navigational radiofrequency probe to ablate acetabular metastases from an anterior approach followed by instillation of ultrahigh viscosity cement under CT-fluoroscopic guidance. The tumor ablation databases of two institutions were retrospectively reviewed to identify patients who underwent combination acetabular radiofrequency ablation and cementoplasty using the STAR Tumor Ablation and StabiliT Vertebral Augmentation Systems (DFINE; San Jose, CA). Pre-procedure acetabular tumor volume was measured on cross-sectional imaging. Pre- and post-procedure pain scores were measured using the Numeric Rating Scale (10-point scale) and compared. Partial pain improvement was categorically defined as ≥ 2-point pain score reduction. Patients were evaluated for evidence of immediate complications. Electronic medical records were reviewed for evidence of delayed complications. During the study period, 12 patients with acetabular metastases were treated. The median tumor volume was 54.3 mL (range, 28.3-109.8 mL). Pre- and post-procedure pain scores were obtained from 92% (11/12) of the cohort. The median pre-procedure pain score was 8 (range, 3-10). Post-procedure pain scores were obtained 7 days (82%; 9/11), 11 days (9.1%; 1/11) or 21 days (9.1%; 1/11) after treatment. The median post-treatment pain score was 3 (range, 1-8), a statistically significant difference compared with pre-treatment (P = 0.002). Categorically, 73% (8/11) of patients reported partial pain relief after treatment. No immediate symptomatic complications occurred. Three patients (25%; 3/12) were discharged to hospice within 1 week of treatment. No delayed complications occurred in the remaining 75% (9/12) of patients during median clinical follow-up of 62 days (range, 14-178 days). Palliative percutaneous

  6. Imaging and histology in the diagnosis of multiple papillary fibroelastomas in a patient with hypertrophic obstructive cardiomyopathy. Case report.

    Science.gov (United States)

    Ionescu, Alin Alexandru; Radulescu, Bogdan; Herlea, Vlad; Miclea, Ioan; Parepa, Irinel; Bubenek, Serban; Popescu, Bogdan Alexandru; Ginghina, Carmen; Jurcut, Ruxandra

    2017-11-29

    Papillary fibroelastomas (PFEs) are one of the most frequent primary cardiac tumors and occur more often in patients with hypertrophic obstructive cardiomyopathy (HOCM). PFEs have been linked to an increased risk of neurological events. We report a case of a 59-year-old woman with HOCM in whom echocardiography (transthoracic and transesophageal, using 2D and 3D techniques) revealed multiple masses in various locations in the left cardiac chambers. Surgical excision of the cardiac tumors and aortic valve replacement was performed and the pathologic report confirmed the diagnosis of PFEs. Patient followup using ultrasonography is crucial since recurrence is a possibility. Current cardiac ultrasound techniques are essential for diagnosing and for guiding the management of these conditions.

  7. Development of laser ablation plasma by anisotropic self-radiation

    Directory of Open Access Journals (Sweden)

    Ohnishi Naofumi

    2013-11-01

    Full Text Available We have proposed a method for reproducing an accurate solution of low-density ablation plasma by properly treating anisotropic radiation. Monte-Carlo method is employed for estimating Eddington tensor with limited number of photon samples in each fluid time step. Radiation field from ablation plasma is significantly affected by the anisotropic Eddington tensor. Electron temperature around the ablation surface changes with the radiation field and is responsible for the observed emission. An accurate prediction of the light emission from the laser ablation plasma requires a careful estimation of the anisotropic radiation field.

  8. Individualized laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer.

    Science.gov (United States)

    Xu, Zhifeng; Yang, Zhangwei; Pan, Jianghua; Hu, Yiren

    2018-03-01

    Liver cancer is one of the most common malignancies of the digestive system. Minimally invasive ablation procedures have become one of the major means for treating unresectable multifocal liver cancer and have been extensively applied in primary and metastatic liver cancer treatment. Laparoscopic B-ultrasound-guided microwave ablation is an example of the progress made in this field. To analyze and summarize the results of and experience with laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer; moreover, the ablation effects were compared between tumors of different sizes. Laparoscope-guided needle ablation was conducted on 84 lesions from 32 patients with primary liver cancer based on tumor size, quantity, and location. Moreover, the perioperative data, ablation effects according to tumor size, and long-term follow-up results were analyzed. Among the 84 nodules treated via microwave ablation, tumors measuring ≤ 3 cm demonstrated complete ablation upon imaging analysis conducted 1 month after surgery. Moreover, 5 of the tumors measuring > 3 cm demonstrated incomplete ablation. In these cases, a second procedure was performed, until imaging studies confirmed that complete ablation was achieved. Laparoscopic microwave ablation allows for precise puncture positioning, an effective ablation range, and safe and feasible surgery, which is especially suitable for liver tumors located in sites difficult to access.

  9. Subtotal Ablation of Parietal Epithelial Cells Induces Crescent Formation

    Science.gov (United States)

    Sicking, Eva-Maria; Fuss, Astrid; Uhlig, Sandra; Jirak, Peggy; Dijkman, Henry; Wetzels, Jack; Engel, Daniel R.; Urzynicok, Torsten; Heidenreich, Stefan; Kriz, Wilhelm; Kurts, Christian; Ostendorf, Tammo; Floege, Jürgen; Smeets, Bart

    2012-01-01

    Parietal epithelial cells (PECs) of the renal glomerulus contribute to the formation of both cellular crescents in rapidly progressive GN and sclerotic lesions in FSGS. Subtotal transgenic ablation of podocytes induces FSGS but the effect of specific ablation of PECs is unknown. Here, we established an inducible transgenic mouse to allow subtotal ablation of PECs. Proteinuria developed during doxycycline-induced cellular ablation but fully reversed 26 days after termination of doxycycline administration. The ablation of PECs was focal, with only 30% of glomeruli exhibiting histologic changes; however, the number of PECs was reduced up to 90% within affected glomeruli. Ultrastructural analysis revealed disruption of PEC plasma membranes with cytoplasm shedding into Bowman’s space. Podocytes showed focal foot process effacement, which was the most likely cause for transient proteinuria. After >9 days of cellular ablation, the remaining PECs formed cellular extensions to cover the denuded Bowman’s capsule and expressed the activation marker CD44 de novo. The induced proliferation of PECs persisted throughout the observation period, resulting in the formation of typical cellular crescents with periglomerular infiltrate, albeit without accompanying proteinuria. In summary, subtotal ablation of PECs leads the remaining PECs to react with cellular activation and proliferation, which ultimately forms cellular crescents. PMID:22282596

  10. Chemothermal Therapy for Localized Heating and Ablation of Tumor

    Directory of Open Access Journals (Sweden)

    Zhong-Shan Deng

    2013-01-01

    Full Text Available Chemothermal therapy is a new hyperthermia treatment on tumor using heat released from exothermic chemical reaction between the injected reactants and the diseased tissues. With the highly minimally invasive feature and localized heating performance, this method is expected to overcome the ubiquitous shortcomings encountered by many existing hyperthermia approaches in ablating irregular tumor. This review provides a relatively comprehensive review on the latest advancements and state of the art in chemothermal therapy. The basic principles and features of two typical chemothermal ablation strategies (acid-base neutralization-reaction-enabled thermal ablation and alkali-metal-enabled thermal/chemical ablation are illustrated. The prospects and possible challenges facing chemothermal ablation are analyzed. The chemothermal therapy is expected to open many clinical possibilities for precise tumor treatment in a minimally invasive way.

  11. CT thermometry for cone-beam CT guided ablation

    Science.gov (United States)

    DeStefano, Zachary; Abi-Jaoudeh, Nadine; Li, Ming; Wood, Bradford J.; Summers, Ronald M.; Yao, Jianhua

    2016-03-01

    Monitoring temperature during a cone-beam CT (CBCT) guided ablation procedure is important for prevention of over-treatment and under-treatment. In order to accomplish ideal temperature monitoring, a thermometry map must be generated. Previously, this was attempted using CBCT scans of a pig shoulder undergoing ablation.1 We are extending this work by using CBCT scans of real patients and incorporating more processing steps. We register the scans before comparing them due to the movement and deformation of organs. We then automatically locate the needle tip and the ablation zone. We employ a robust change metric due to image noise and artifacts. This change metric takes windows around each pixel and uses an equation inspired by Time Delay Analysis to calculate the error between windows with the assumption that there is an ideal spatial offset. Once the change map is generated, we correlate change data with measured temperature data at the key points in the region. This allows us to transform our change map into a thermal map. This thermal map is then able to provide an estimate as to the size and temperature of the ablation zone. We evaluated our procedure on a data set of 12 patients who had a total of 24 ablation procedures performed. We were able to generate reasonable thermal maps with varying degrees of accuracy. The average error ranged from 2.7 to 16.2 degrees Celsius. In addition to providing estimates of the size of the ablation zone for surgical guidance, 3D visualizations of the ablation zone and needle are also produced.

  12. Efficacy of microwave ablation versus radiofrequency ablation for the treatment of hepatocellular carcinoma in patients with chronic liver disease: a randomised controlled phase 2 trial.

    Science.gov (United States)

    Vietti Violi, Naïk; Duran, Rafael; Guiu, Boris; Cercueil, Jean-Pierre; Aubé, Christophe; Digklia, Antonia; Pache, Isabelle; Deltenre, Pierre; Knebel, Jean-François; Denys, Alban

    2018-05-01

    Radiofrequency ablation is the recommended treatment for patients with hepatocellular carcinoma who have lesions smaller than 3 cm and are therefore not candidates for surgery. Microwave ablation is a more recent technique with certain theoretical advantages that have not yet been confirmed clinically. We aimed to compare the efficacy of both techniques in the treatment of hepatocellular carcinoma lesions of 4 cm or smaller. We did a randomised controlled, single-blinded phase 2 trial at four tertiary university centres in France and Switzerland. Patients with chronic liver disease and hepatocellular carcinoma with up to three lesions of 4 cm or smaller who were not eligible for surgery were randomised to receive microwave ablation (experimental group) or radiofrequency ablation (control group). Randomisation was centralised and done by use of a fixed block method (block size 4). Patients were randomly assigned by a co-investigator by use of the sealed opaque envelope method and were masked to the treatment; physicians were not masked to treatment, since the devices used were different. The primary outcome was the proportion of lesions with local tumour progression at 2 years of follow-up. Local tumour progression was defined as the appearance of a new nodule with features typical of hepatocellular carcinoma in the edge of the ablation zone. All analyses were done in the per-protocol population. The study is completed, but patients will continue to be followed up for 5 years. This study is registered with ClinicalTrials.gov, number NCT02859753. Between Nov 15, 2011, and Feb 27, 2015, 152 patients were randomly assigned: 76 patients to receive microwave ablation and 76 patients to receive radiofrequency ablation. For the per-protocol analysis, five patients were excluded from the microwave ablation group as were three patients from the radiofrequency ablation group. Median follow-up was 26 months (IQR 18-29) in the microwave ablation group and 25 months (18-34) in

  13. Nephron-sparing percutaneous ablation of a 5 cm renal cell carcinoma by superselective embolization and percutaneous RF-ablation

    Energy Technology Data Exchange (ETDEWEB)

    Tacke, J.; Mahnken, A.; Buecker, A.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Rohde, D. [Technische Hochschule Aachen (Germany). Abt. Urologie

    2001-11-01

    Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 {mu}m) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow up CT one day and 4 weeks after the radiofrequency intervention revealed no signs of residual tumor growth. Conclusion: The combined transcatheter embolization and percutaneous radiofrequency ablation of renal cell carcinoma has proved technically feasible, effective, and safe in this patient. It may be offered as an alternative treatment to partial or radical nephrectomy under certain circumstances. Abbreviations: RF = radiofrequency ablation; CT = computed tomography; HIV = human immunodeficiency virus. (orig.) [German] Ziel: Bericht ueber eine nierenschonende, perkutane Ablation eines 5 cm grossen Nierenzellkarzinoms durch kombinierte Transkatheterembolisation und perkutane Radiofrequenzablation. Material und Methoden: Ein 5 cm grosses Nierenzellkarzinom eines 43 Jahre alten Drogenabhaengigen mit serologisch nachgewiesener HIV, Hepatitis B- und C-Infektion, der eine operative Therapie ablehnte, wurde superselektiv durch Embosphaeren (Partikelgroesse: 500 - 700 {mu}m) und einer Platinspirale unter Lokalanaesthesie embolisiert. Am Folgetag

  14. Hyperkalaemia after radiofrequency ablation of hepatocellular carcinoma

    NARCIS (Netherlands)

    Verhoevena, BH; Haagsma, EB; Appeltans, BMG; Slooff, MJH; de Jong, KP

    Radiofrequency ablation of liver tumours is a useful therapy for otherwise unresectable tumours. The complication rate is said to be low. In this case report we describe hyperkalaemia after radiofrequency ablation of a hepatocellular carcinoma in a patient with end-stage renal insufficiency. (C)

  15. Halogenated anaesthetics and cardiac protection in cardiac and non-cardiac anaesthesia

    Directory of Open Access Journals (Sweden)

    Landoni Giovanni

    2009-01-01

    Full Text Available Volatile anaesthetic agents have direct protective properties against ischemic myocardial damage. The implementation of these properties during clinical anaesthesia can provide an additional tool in the treatment or prevention, or both, of ischemic cardiac dysfunction in the perioperative period. A recent meta-analysis showed that desflurane and sevoflurane reduce postoperative mortality and incidence of myocardial infarction following cardiac surgery, with significant advantages in terms of postoperative cardiac troponin release, need for inotrope support, time on mechanical ventilation, intensive care unit and overall hospital stay. Multicentre, randomised clinical trials had previously demonstrated that the use of desflurane can reduce the postoperative release of cardiac troponin I, the need for inotropic support, and the number of patients requiring prolonged hospitalisation following coronary artery bypass graft surgery either with and without cardiopulmonary bypass. The American College of Cardiology/American Heart Association Guidelines recommend volatile anaesthetic agents during non-cardiac surgery for the maintenance of general anaesthesia in patients at risk for myocardial infarction. Nonetheless, e vidence in non-coronary surgical settings is contradictory and will be reviewed in this paper together with the mechanisms of cardiac protection by volatile agents.

  16. Efficacy and satisfaction rate comparing endometrial ablation by rollerball electrocoagulation to uterine balloon thermal ablation in a randomised controlled trial.

    NARCIS (Netherlands)

    Zon-Rabelink, I.A.A. van; Vleugels, M.P.; Merkus, J.M.W.M.; Graaf, R.M. de

    2004-01-01

    OBJECTIVE: To compare two methods of endometrial ablation, hysteroscopic rollerball electrocoagulation (RBE) and non-hysteroscopic uterine balloon thermal ablation (Thermachoice trade mark ), regarding efficacy for reducing dysfunctional uterine bleeding and patients satisfaction rate. METHODS: A

  17. Dynamic behaviors of laser ablated Si particles

    International Nuclear Information System (INIS)

    Ohyanagi, T.; Murakami, K.; Miyashita, A.; Yoda, O.

    1995-01-01

    The dynamics of laser-ablated Si particles produced by laser ablation have been investigated by time-and-space resolved X-ray absorption spectroscopy in a time scale ranging from 0 ns to 120 ns with a time resolution of 10 ns. Neutral and charged particles are observed through all X-ray absorption spectra. Assignments of transitions from 2s and 2p initial states to higher Rydberg states of Si atom and ions are achieved, and we experimentally determine the L II,III absorption edges of neutral Si atom (Si 0 ) and Si + , Si 2+ , Si 3+ and Si 4+ ions. The main ablated particles are found to be Si atom and Si ions in the initial stage of 0 ns to 120 ns. The relative amounts depend strongly on times and laser energy densities. We find that the spatial distributions of particles produced by laser ablation are changed with supersonic helium gas bombardment, but no cluster formation takes place. This suggests that a higher-density region of helium gas is formed at the top of the plume of ablated particles, and free expansion of particles is restrained by this helium cloud, and that it takes more than 120 ns to form Si clusters. (author)

  18. Radiofrequency ablation of liver tumors (II): clinical application and outcomes.

    Science.gov (United States)

    Vanagas, Tomas; Gulbinas, Antanas; Pundzius, Juozas; Barauskas, Giedrius

    2010-01-01

    Radiofrequency ablation is one of the alternatives in the management of liver tumors, especially in patients who are not candidates for surgery. The aim of this article is to review applicability of radiofrequency ablation achieving complete tumor destruction, utility of imaging techniques for patients' follow-up, indications for local ablative procedures, procedure-associated morbidity and mortality, and long-term results in patients with different tumors. The success of local thermal ablation consists in creating adequate volumes of tissue destruction with adequate "clear margin," depending on improved delivery of radiofrequency energy and modulated tissue biophysiology. Different volumes of coagulation necrosis are achieved applying different types of electrodes, pulsing energy sources, utilizing sophisticated ablation schemes. Some additional methods are used to increase the overall deposition of energy through alterations in tissue electrical conductivity, to improve heat retention within the tissue, and to modulate tolerance of tumor tissue to hyperthermia. Contrast-enhanced computed tomography, magnetic resonance imaging, ultrasound or positron emission tomography are applied to control the effectiveness of radiofrequency ablation. The long-term results of radiofrequency ablation are controversial.

  19. Optical properties of tin oxide nanoparticles prepared by laser ablation in water: Influence of laser ablation time duration and laser fluence

    International Nuclear Information System (INIS)

    Desarkar, Himadri Sankar; Kumbhakar, P.; Mitra, A.K.

    2012-01-01

    Colloidal tin oxide nanoparticles are prepared by laser (having a wavelength of 1064 nm) ablation of tin metallic target immersed in pure deionized water. The influences of laser ablation time and laser fluence on the size and optical properties of the synthesized nanoparticles are studied. Prepared tin oxide nanoparticles are characterized by transmission electron microscope, selected area electron diffraction and UV–Visible absorption spectroscopy. The morphology of prepared tin oxide nanoparticles is found to be mostly spherical and with sizes in the nanometric range (mean radius of 3.2 to 7.3 nm). The measured UV–Visible absorption spectra show the presence of absorption peaks in the ultraviolet region. The band gap energy of samples prepared with different laser ablation time duration is calculated and is found to be increased with decrease in size (radius) of the prepared nanoparticles. Photoluminescence emission measurements at room temperature show that all the samples exhibit photoluminescence in the visible region. The peak photoluminescence emission intensity in the sample prepared with 50 min of laser ablation time is 3.5 times larger than that obtained in the sample prepared with 10 min of laser ablation time. - Highlights: ► SnO 2 nanoparticles (6.4–14.6 nm) are prepared by laser ablation in liquid technique. ► The influences of laser ablation time and laser fluence are studied. ► Samples are characterized by TEM and UV–Visible absorption spectroscopy. ► UV–Visible absorption spectra exhibit quantum confinement effect. ► Samples exhibit enhanced photoluminescence emissions in the visible region.

  20. Effect of liquid film on near-threshold laser ablation of a solid surface

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dongsik; Oh, Bukuk; Lee, Ho

    2004-01-30

    Enhancement of material ablation and photoacoustic excitation by an artificially deposited liquid film in the process of pulsed-laser ablation (PLA) is investigated in this paper. Ablation threshold, ablation rate, surface topography, and acoustic-transient emission are also measured for dry and liquid film-coated surfaces. The physical mechanisms of enhanced ablation in the liquid-assisted process are analyzed at relatively low laser fluences with negligible effect of laser-produced plasma. Particularly, correlation between material ablation and acoustic-transient generation is examined. In the experiment, aluminum thin-films and bulk foils are ablated by Q-switched Nd:YAG laser pulses. The dependence of ablation rate and laser-induced topography on liquid film thickness and chemical composition is also examined. Photoacoustic emission is measured by the probe beam deflection method utilizing a CW HeNe laser and a microphone. In comparison with a dry ablation process, the liquid-assisted ablation process results in substantially augmented ablation efficiency and reduced ablation threshold. The results indicate that both increased laser-energy coupling, i.e., lowered reflectance, and amplified photoacoustic excitation in explosive vaporization of liquid are responsible for the enhanced material ablation.

  1. Effect of carbide particles on the ablation properties of tungsten composites

    International Nuclear Information System (INIS)

    Song Guiming; Zhou Yu; Wang Yujin

    2003-01-01

    The high temperature ablation behavior of tungsten composites containing carbides produced by vacuum hot pressing is studied as a function of reinforcement chemistry (ZrC and TiC) and content using a self-made oxyacetylene ablation equipment. A dynamic responding multiwavelength pyrometer was employed to measure the temperature of the ablation surface, and a thermocouple was employed to measure the temperature of the back surface during the time that a specimen was being ablated. The mass and linear ablation rates are lower in composites containing ZrC, decreasing with increasing particle content in both composites system. The values of the mass and linear ablation rates were in the order from high to low: W>30TiC/W>40TiC/W>30ZrC/W>40ZrC/W (30TiC/W stands for 30 vol.% TiC particle content in the W matrix, the same below). The important temperature curves of the ablation surfaces of specimens were successfully detected online. Ablated surfaces and vertical sections of the specimens were investigated using scanning electron microscopy (SEM) and X-ray diffraction (XRD). Thermochemical oxidation of tungsten, TiC, and ZrC was the main ablation mechanism of ZrC/W and TiC/W composites. These ablation behaviors are discussed based on the thermophysical and chemical properties of both the composite systems

  2. Ablation of liver metastases by radiofrequency

    International Nuclear Information System (INIS)

    Baere, T. de

    2012-01-01

    Radiofrequency is a thermal ablative technique that is most often used percuteanously under image guidance. Thermal damage is obtained through frictional heating of a high frequency current. The maximal volume of destruction obtained in one radiofrequency delivery is around 4 cm and consequently, best indication for treatment are tumours below 3 cm. When compared, radiofrequency and surgical removal for tumours below 25 mm in diameter demonstrated a rate of incomplete resection/ablation of 6% and 7.3% respectively. Median survival after the first radiofrequency of a liver metastasis of CRC is reported to be 24 to 52 months with a 5 years overall survival of 18 to 44%. The median overall survival increases from 22 to 48 months depending on the use of radiofrequency ablation as rescue treatment after failure of others, or as a first line treatment. For patients with a single tumour, less than 4 cm, the survival rates at 1, 3, and 5 years are respectively 97%, 84% and 40%, with a median survival of 50 months. Follow-up imaging requires to use contrast-enhanced CT or MRI, looking for local recurrences evidenced by local foci of enhancement at the periphery of the ablation zone. (author)

  3. Extremely low-frame-rate digital fluoroscopy in catheter ablation of atrial fibrillation: A comparison of 2 versus 4 frame rate.

    Science.gov (United States)

    Lee, Ji Hyun; Kim, Jun; Kim, Minsu; Hwang, Jongmin; Hwang, You Mi; Kang, Joon-Won; Nam, Gi-Byoung; Choi, Kee-Joon; Kim, You-Ho

    2017-06-01

    Despite the technological advance in 3-dimensional (3D) mapping, radiation exposure during catheter ablation of atrial fibrillation (AF) continues to be a major concern in both patients and physicians. Previous studies reported substantial radiation exposure (7369-8690 cGy cm) during AF catheter ablation with fluoroscopic settings of 7.5 frames per second (FPS) under 3D mapping system guidance. We evaluated the efficacy and safety of a low-frame-rate fluoroscopy protocol for catheter ablation for AF.Retrospective analysis of data on 133 patients who underwent AF catheter ablation with 3-D electro-anatomic mapping at our institute from January 2014 to May 2015 was performed. Since January 2014, fluoroscopy frame rate of 4-FPS was implemented at our institute, which was further decreased to 2-FPS in September 2014. We compared the radiation exposure quantified as dose area product (DAP) and effective dose (ED) between the 4-FPS (n = 57) and 2-FPS (n = 76) groups.The 4-FPS group showed higher median DAP (599.9 cGy cm; interquartile range [IR], 371.4-1337.5 cGy cm vs. 392.0 cGy cm; IR, 289.7-591.4 cGy cm; P FPS group. No major procedure-related complications such as cardiac tamponade were observed in either group. Over follow-up durations of 331 ± 197 days, atrial tachyarrhythmia recurred in 20 patients (35.1%) in the 4-FPS group and in 27 patients (35.5%) in the 2-FPS group (P = .96). Kaplan-Meier survival analysis revealed no significant different between the 2 groups (log rank, P = .25).In conclusion, both the 4-FPS and 2-FPS settings were feasible and emitted a relatively low level of radiation compared with that historically reported for DAP in a conventional fluoroscopy setting.

  4. Improvement of the surface finish obtained by laser ablation with a Nd: YAG laser on pre-ablated tool steel

    CSIR Research Space (South Africa)

    Steyn, J

    2007-01-01

    Full Text Available . In recent years, these lasers have been used in other fields, such as laser ablation of small tools for plastics injection moulding. Laser ablation is a technology that is investigated as a method to improve the surface finish in tool steel. Different...

  5. 308-nm excimer laser ablation of human cartilage

    Science.gov (United States)

    Prodoehl, John A.; Rhodes, Anthony L.; Meller, Menachem M.; Sherk, Henry H.

    1993-07-01

    The XeCl excimer laser was investigated as an ablating tool for human fibrocartilage and hyaline cartilage. Quantitative measurements were made of tissue ablation rates as a function of fluence in meniscal fibrocartilage and articular hyaline cartilage. A force of 1.47 Newtons was applied to an 800 micrometers fiber with the laser delivering a range of fluences (40 to 190 mj/mm2) firing at a frequency of 5 Hz. To assess the effect of repetition rate on ablation rate, a set of measurements was made at a constant fluence of 60 mj/mm2, with the repetition rate varying from 10 to 40 Hz. Histologic and morphometric analysis was performed using light microscopy. The results of these studies revealed that the ablation rate was directly proportional to fluence over the range tested. Fibrocartilage was ablated at a rate 2.56 times faster than hyaline cartilage at the maximum fluence tested. Repetition rate had no effect on the penetration per pulse. Adjacent tissue damage was noted to be minimal (10 - 70 micrometers ).

  6. Computational modeling of ultra-short-pulse ablation of enamel

    Energy Technology Data Exchange (ETDEWEB)

    London, R.A.; Bailey, D.S.; Young, D.A. [and others

    1996-02-29

    A computational model for the ablation of tooth enamel by ultra-short laser pulses is presented. The role of simulations using this model in designing and understanding laser drilling systems is discussed. Pulses of duration 300 sec and intensity greater than 10{sup 12} W/cm{sup 2} are considered. Laser absorption proceeds via multi-photon initiated plasma mechanism. The hydrodynamic response is calculated with a finite difference method, using an equation of state constructed from thermodynamic functions including electronic, ion motion, and chemical binding terms. Results for the ablation efficiency are presented. An analytic model describing the ablation threshold and ablation depth is presented. Thermal coupling to the remaining tissue and long-time thermal conduction are calculated. Simulation results are compared to experimental measurements of the ablation efficiency. Desired improvements in the model are presented.

  7. Femtosecond pulsed laser ablation of GaAs

    International Nuclear Information System (INIS)

    Trelenberg, T.W.; Dinh, L.N.; Saw, C.K.; Stuart, B.C.; Balooch, M.

    2004-01-01

    The properties of femtosecond-pulsed laser deposited GaAs nanoclusters were investigated. Nanoclusters of GaAs were produced by laser ablating a single crystal GaAs target in vacuum or in a buffer gas using a Ti-sapphire laser with a 150 fs minimum pulse length. For in-vacuum deposition, X-ray diffraction (XRD), scanning electron microscopy (SEM), and atomic force microscopy (AFM) revealed that the average cluster size was approximately 7 nm for laser pulse lengths between 150 fs and 25 ps. The average cluster size dropped to approximately 1.5 nm at a pulse length of 500 ps. It was also observed that film thickness decreased with increasing laser pulse length. A reflective coating, which accumulated on the laser admission window during ablation, reduced the amount of laser energy reaching the target for subsequent laser shots and developed more rapidly at longer pulse lengths. This observation indicates that non-stoichiometric (metallic) ablatants were produced more readily at longer pulse lengths. The angular distribution of ejected material about the target normal was well fitted to a bi-cosine distribution of cos 47 θ+ cos 4 θ for ablation in vacuum using 150 fs pulses. XPS and AES revealed that the vacuum-deposited films contained excess amorphous Ga or As in addition to the stoichiometric GaAs nanocrystals seen with XRD. However, films containing only the GaAs nanocrystals were produced when ablation was carried out in the presence of a buffer gas with a pressure in excess of 6.67 Pa. At buffer gas pressure on the order of 1 Torr, it was found that the stoichiometry of the ablated target was also preserved. These experiments indicate that both laser pulse length and buffer gas pressure play important roles in the formation of multi-element nanocrystals by laser ablation. The effects of gas pressure on the target's morphology and the size of the GaAs nanocrystals formed will also be discussed

  8. Percutaneous radiofrequency ablation of renal tumors: Midterm results in 16 patients

    International Nuclear Information System (INIS)

    Memarsadeghi, Mazda; Schmook, Theresia; Remzi, Mesut; Weber, Michael; Poetscher, Gerda; Lammer, Johannes; Kettenbach, Joachim

    2006-01-01

    Purpose: To evaluate the outcome of 16 patients after percutaneous radiofrequency ablation of renal tumors. Materials and methods: Sixteen patients (nine women, seven men; mean age, 61 ± 9 years) with 24 unresectable renal tumors (mean volume, 4.3 ± 4.3 cm 3 ) underwent CT-guided (n = 20) or MR imaging-guided (n = 4) percutaneous radiofrequency ablation using an expandable electrode (Starburst XL TM , RITA Medical Systems, Mountain View, CA) with a 150-W generator. The initial follow-up imaging was performed within 1-30 days after RF ablation, then at 3-6 month intervals using either CT or MRI. Residual tumor volume and coagulation necrosis was assessed, and statistical correlation tests were obtained to determine the strength of the relationship between necrosis volume and number of ablations. Results: Overall, 97 overlapping RF ablations were performed (mean, 3.5 ± 1.5 ablations per tumor) during 24 sessions. Five or more RF ablations per tumor created significant larger necrosis volumes than 1-2 (p .034) or 3-4 ablations (p = .020). A complete ablation was achieved in 20/24 tumors (primary technical success, 83%; mean volume of coagulation necrosis: 10.2 ± 7.2 cm 3 ). Three of four residual tumors were retreated and showed complete necrosis thereafter. Three major complications (one percuatneous urinary fistula and two ureteral strictures) were observed after RF ablation. No further clinically relevant complications were observed and renal function remained stable. During a mean follow-up of 11.2 months (range, 0.2-31.5), 15/16 patients (94%) were alive. Only one patient had evidence of local recurrent tumor. Conclusion: The midterm results of percutaneous RF ablation for renal tumors are promising and show that RF ablation is well-suited to preserve renal function

  9. Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management.

    Science.gov (United States)

    Ostrowski, Stanisław; Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwoliński, Radosław; Jaszewski, Ryszard

    2015-09-01

    Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case. The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs' surface was found. A biological aortic prosthesis was reimplanted without complications. The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored. Precise and modern diagnostic methods

  10. Transhemangioma Ablation of Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Pua, Uei

    2012-01-01

    Radiofrequency ablation (RFA) is a well-established treatment modality in the treatment of early hepatocellular carcinoma (HCC) [1]. Safe trajectory of the RFA probe is crucial in decreasing collateral tissue damage and unwarranted probe transgression. As a percutaneous technique, however, the trajectory of the needle is sometimes constrained by the available imaging plane. The presence of a hemangioma beside an HCC is uncommon but poses the question of safety related to probe transgression. We hereby describe a case of transhemangioma ablation of a dome HCC.

  11. Transhemangioma Ablation of Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2012-12-15

    Radiofrequency ablation (RFA) is a well-established treatment modality in the treatment of early hepatocellular carcinoma (HCC) [1]. Safe trajectory of the RFA probe is crucial in decreasing collateral tissue damage and unwarranted probe transgression. As a percutaneous technique, however, the trajectory of the needle is sometimes constrained by the available imaging plane. The presence of a hemangioma beside an HCC is uncommon but poses the question of safety related to probe transgression. We hereby describe a case of transhemangioma ablation of a dome HCC.

  12. Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization

    International Nuclear Information System (INIS)

    Sun, Lue; Mizuno, Yusuke; Goto, Takahisa; Iwamoto, Mari; Koguchi, Yasuhiro; Miyamoto, Yuka; Tsuboi, Koji; Chida, Koichi; Moritake, Takashi

    2014-01-01

    Children with complex congenital heart diseases often require repeated cardiac catheterization; however, children are more radiosensitive than adults. Therefore, radiation-induced carcinogenesis is an important consideration for children who undergo those procedures. We measured entrance skin doses (ESDs) using radio-photoluminescence dosimeter (RPLD) chips during cardiac catheterization for 15 pediatric patients (median age, 1.92 years; males, n = 9; females, n = 6) with cardiac diseases. Four RPLD chips were placed on the patient's posterior and right side of the chest. Correlations between maximum ESD and dose-area products (DAP), total number of frames, total fluoroscopic time, number of cine runs, cumulative dose at the interventional reference point (IRP), body weight, chest thickness, and height were analyzed. The maximum ESD was 80 ± 59 (mean ± standard deviation) mGy. Maximum ESD closely correlated with both DAP (r = 0.78) and cumulative dose at the IRP (r = 0.82). Maximum ESD for coiling and ballooning tended to be higher than that for ablation, balloon atrial septostomy, and diagnostic procedures. In conclusion, we directly measured ESD using RPLD chips and found that maximum ESD could be estimated in real-time using angiographic parameters, such as DAP and cumulative dose at the IRP. Children requiring repeated catheterizations would be exposed to high radiation levels throughout their lives, although treatment influences radiation dose. Therefore, the radiation dose associated with individual cardiac catheterizations should be analyzed, and the effects of radiation throughout the lives of such patients should be followed. (author)

  13. Hydrogen pellet ablation and accelerator by current in high temperature plasmas

    International Nuclear Information System (INIS)

    Kuteev, B.V.

    1995-01-01

    Hydrogen pellet ablation and acceleration by current in high temperature plasmas are analyzed. The present state of ablation theory and experiment is discussed and an ablation model is formulated. This model takes into account the energy distribution of the particles (both electrons and ions) participating in the ablation process, electrostatic effects of the cloud charging and changes of the pellet form during ablation. Without charging the pellet form tends to a shape resembling a lentil while it remains almost spherical if charged. A new algorithm for ablation rate calculations that can be used for an arbitrary initial form of the pellet is described. The results of this kinetic two dimensional approach differ from those of the Parks ablation scaling used in the ITER design by not more than 30%. Plasma shielding effects are not significant in the ablation if strong turbulence in the cloud is taken into account. Acceleration analysis is based on the Braginskii corrected electron distribution function. For the lentil mode of ablation, acceleration is higher than those for the charged mode by a factor of 1.76. The ablation models are compared with the experiments on T-10, JET, TFTR, Heliotron-E and Tore Supra. A sensitivity analysis shows that pellet size and electron temperature are the most significant factors for determination of the penetration length. The available database of penetration lengths is not sufficient for distinguishing between the models. Acceleration for the charged model correlates with experimental data better than that for the lentil mode. The effect of the hot ions is seen on the ablation. Finally, ablation at reactor relevant plasma and pellet parameters is considered. This range of the plasma parameters needs a correction of the ablation scaling as follows: dN/dt ∼ n 0.453 e T 1.72 e r 1.443 p M -0.283 i , where n e and T e are the electron density and temperature, respectively, and r p and M i are the pellet radius and atomic mass

  14. Histopathology of cryoballoon ablation-induced phrenic nerve injury.

    Science.gov (United States)

    Andrade, Jason G; Dubuc, Marc; Ferreira, Jose; Guerra, Peter G; Landry, Evelyn; Coulombe, Nicolas; Rivard, Lena; Macle, Laurent; Thibault, Bernard; Talajic, Mario; Roy, Denis; Khairy, Paul

    2014-02-01

    Hemi-diaphragmatic paralysis is the most common complication associated with cryoballoon ablation for atrial fibrillation, yet the histopathology of phrenic nerve injury has not been well described. A preclinical randomized study was conducted to characterize the histopathology of phrenic nerve injury induced by cryoballoon ablation and assess the potential for electromyographic (EMG) monitoring to limit phrenic nerve damage. Thirty-two dogs underwent cryoballoon ablation of the right superior pulmonary vein with the objective of inducing phrenic nerve injury. Animals were randomized 1:1 to standard monitoring (i.e., interruption of ablation upon reduction in diaphragmatic motion) versus EMG guidance (i.e., cessation of ablation upon a 30% reduction in the diaphragmatic compound motor action potential [CMAP] amplitude). The acute procedural endpoint was achieved in all dogs. Phrenic nerve injury was characterized by Wallerian degeneration, with subperineural injury to large myelinated axons and evidence of axonal regeneration. The degree of phrenic nerve injury paralleled the reduction in CMAP amplitude (P = 0.007). Animals randomized to EMG guidance had a lower incidence of acute hemi-diaphragmatic paralysis (50% vs 100%; P = 0.001), persistent paralysis at 30 days (21% vs 75%; multivariate odds ratio 0.12, 95% confidence interval [0.02, 0.69], P = 0.017), and a lesser severity of histologic injury (P = 0.001). Mature pulmonary vein ablation lesion characteristics, including circumferentiality and transmurality, were similar in both groups. Phrenic nerve injury induced by cryoballoon ablation is axonal in nature and characterized by Wallerian degeneration, with potential for recovery. An EMG-guided approach is superior to standard monitoring in limiting phrenic nerve damage. © 2013 Wiley Periodicals, Inc.

  15. Radiofrequency ablation for hepatocellular carcinoma: assistant techniques for difficult cases.

    Science.gov (United States)

    Inoue, Tatsuo; Minami, Yasunori; Chung, Hobyung; Hayaishi, Sousuke; Ueda, Taisuke; Tatsumi, Chie; Takita, Masahiro; Kitai, Satoshi; Hatanaka, Kinuyo; Ishikawa, Emi; Yada, Norihisa; Hagiwara, Satoru; Ueshima, Kazuomi; Kudo, Masatoshi

    2010-07-01

    To confirm the safety and effectiveness of techniques to assist radiofrequency ablation (RFA) for difficult cases, we retrospectively evaluated successful treatment rates, early complications and local tumor progressions. Between June 1999 and April 2009, a total of 341 patients with 535 nodules were treated as difficult cases. Artificial pleural effusion assisted ablation was performed on 64 patients with 82 nodules. Artificial ascites-assisted ablation was performed on 11 patients with 13 nodules. Cooling by endoscopic nasobiliary drainage (ENBD) tube-assisted ablation was performed on 6 patients with 8 nodules. When the tumors were not well visualized with conventional B-mode ultrasonography (US), contrast-enhanced US-assisted ablation with Levovist or Sonazoid or virtual CT sonography-assisted ablation was performed. Contrast-enhanced US-assisted ablation was performed on 139 patients with 224 nodules and virtual CT sonography-assisted ablation was performed on 121 patients with 209 nodules. In total, complete ablation was achieved in 514 of 535 (96%) nodules in difficult cases. For RFA with artificial pleural effusion, artificial ascites and ENBD, complete response was confirmed in all cases. For contrast-enhanced US- and CT sonography-assisted ablation, complete response was 95%. Early complications were recognized in 24 cases (4.5%). All cases recovered with no invasive treatment. Local tumor recurrence was investigated in 377 nodules of 245 patients, and 69 (18%) nodules were positive. Tumor recurrences in each assisted technique were 14.7% in artificial pleural effusion cases, 7% in artificial ascites, 12.5% in ENBD tube cases, 31% in virtual CT sonography, and 8.5% in contrast-enhanced US. Although local tumor progression needs to be carefully monitored, assisted techniques of RFA for difficult cases are well tolerated and expand the indications of RFA. Copyright (c) 2010 S. Karger AG, Basel.

  16. Effects of endocardial microwave energy ablation

    Directory of Open Access Journals (Sweden)

    Vicente Climent

    2005-07-01

    Full Text Available Until recently the treatment of atrial fibrillation (AF consisted primarily of palliation, mostly in the form of pharmacological intervention. However because of recent advances in nonpharmacologic therapies, the current expectation of patients and referring physicians is that AF will be cured, rather than palliated. In recent years there has been a rapid expansion in the availability and variety of energy sources and devices for ablation. One of these energies, microwave, has been applied clinically only in the last few years, and may be a promising technique that is potentially capable of treating a wide range of ventricular and supraventricular arrhythmias. The purpose of this study was to review microwave energy ablation in surgical treatment of AF with special interest in histology and ultrastructure of lesions produced by this endocardial ablation procedure.

  17. Deep Dive Topic: Choosing between ablators

    Energy Technology Data Exchange (ETDEWEB)

    Hurricane, O. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Thomas, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Olson, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-07-14

    Recent data on implosions using identical hohlraums and very similar laser drives underscores the conundrum of making a clear choice of one ablator over another. Table I shows a comparison of Be and CH in a nominal length, gold, 575 μm-diameter, 1.6 mg/cc He gas-fill hohlraum while Table II shows a comparison of undoped HDC and CH in a +700 length, gold, 575 μm diameter, 1.6 mg/cc He gas fill hohlraum. As can be seen in the tables, the net integrated fusion performance of these ablators is the same to within error bars. In the case of the undoped HDC and CH ablators, the hot spot shapes of the implosions were nearly indistinguishable for the experiments listed in Table II.

  18. Image-Guided Spinal Ablation: A Review

    Energy Technology Data Exchange (ETDEWEB)

    Tsoumakidou, Georgia, E-mail: gtsoumakidou@yahoo.com; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr; Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr; Garnon, Julien, E-mail: julien.garnon@chru-strasbourg.fr; Cazzato, Roberto Luigi, E-mail: roberto-luigi.cazzato@chru-strasbourg.fr; Edalat, Faramarz, E-mail: faramarz.edalat@gmail.com; Gangi, Afshin, E-mail: gangi@unistra.fr [Strasbourg University Hospital (France)

    2016-09-15

    The image-guided thermal ablation procedures can be used to treat a variety of benign and malignant spinal tumours. Small size osteoid osteoma can be treated with laser or radiofrequency. Larger tumours (osteoblastoma, aneurysmal bone cyst and metastasis) can be addressed with radiofrequency or cryoablation. Results on the literature of spinal microwave ablation are scarce, and thus it should be used with caution. A distinct advantage of cryoablation is the ability to monitor the ice-ball by intermittent CT or MRI. The different thermal insulation, temperature and electrophysiological monitoring techniques should be applied. Cautious pre-procedural planning and intermittent intra-procedural monitoring of the ablation zone can help reduce neural complications. Tumour histology, patient clinical-functional status and life-expectancy should define the most efficient and least disabling treatment option.

  19. Effect analysis of material properties of picosecond laser ablation for ABS/PVC

    Science.gov (United States)

    Tsai, Y. H.; Ho, C. Y.; Chiou, Y. J.

    2017-06-01

    This paper analytically investigates the picosecond laser ablation of ABS/PVC. Laser-pulsed ablation is a wellestablished tool for polymer. However the ablation mechanism of laser processing for polymer has not been thoroughly understood yet. This study utilized a thermal transport model to analyze the relationship between the ablation rate and laser fluences. This model considered the energy balance at the decomposition interface and Arrhenius law as the ablation mechanisms. The calculated variation of the ablation rate with the logarithm of the laser fluence agrees with the measured data. It is also validated in this work that the variation of the ablation rate with the logarithm of the laser fluence obeys Beer's law for low laser fluences. The effects of material properties and processing parameters on the ablation depth per pulse are also discussed for picosecond laser processing of ABS/PVC.

  20. Intense harmonic generation from various ablation media

    International Nuclear Information System (INIS)

    Ozaki, T.; Elouga, L.; Suzuki, M.; Kuroda, H.; Ganeev, R.A.

    2006-01-01

    Complete test of publication follows. High-order harmonic generation (HHG) is a unique source of coherent extreme ultraviolet (XUV) radiation, which can produce soft x-rays within the spectral 'water-window' (between 2.3 and 4.4 nm), and ultimately short pulses with attosecond duration. However, the intensity of present-day harmonics is still low, and serious applications will need an increase of the conversion efficiency. Instead of using gas media, one can also use ablation material, produced on solid targets using a low-intensity prepulse, as the nonlinear medium to generate high-order harmonics. Recently, we have successfully demonstrated the generation of up to the 63 rd harmonic (λ = 12.6 nm) of a Ti:sapphire laser radiation using boron ablation, and a strong enhancement in the intensity of the 13 th harmonic from indium ablation. These harmonics were generated with a modest laser (10 mJ, 150 fs) and with the pre-pulse to main pulse energy ratio constant. In this paper, we perform systematic investigations of ablation harmonics, using the 200 mJ, 30 fs Ti:sapphire beam line of the Canadian Advanced Laser Light Source (ALLS) facility. ALLS allows studying ablation harmonics over wider experimental parameters, and with independent control over the pre-pulse and main pulse energies. The 10 Hz, 200 mJ Ti:sapphire beam line of ALLS is divided into two beams. Each beam has its own energy control system, which allows independent control over the energy of each beam. One of the beams is used as a pre-pulse for creating ablation, which is focused onto the solid target without pulse compression, with pulse duration of 200 ps. The second beam is used as the main pulse for harmonic generation. The main pulse is delayed in time relative to the pre-pulse by propagating through an optical delay line, and then sent through a pulse compressor. The compressed pulse duration have typical pulse duration of 30 fs FWHM, which is then focused onto the ablation medium using MgF 2

  1. Assessment of ablative margin after radiofrequency ablation for hepatocellular carcinoma; comparison between magnetic resonance imaging with ferucarbotran and enhanced CT with iodized oil deposition

    International Nuclear Information System (INIS)

    Koda, Masahiko; Tokunaga, Shiho; Fujise, Yuki; Kato, Jun; Matono, Tomomitsu; Sugihara, Takaaki; Nagahara, Takakazu; Ueki, Masaru; Murawaki, Yoshikazu; Kakite, Suguru; Yamashita, Eijiro

    2012-01-01

    Background and purpose: Our aim was to investigate whether magnetic resonance imaging (MRI) with ferucarbotran administered prior to radiofrequency ablation could accurately assess ablative margin when compared with enhanced computed tomography (CT) with iodized oil marking. Materials and methods: We enrolled 27 patients with 32 hepatocellular carcinomas in which iodized oil deposits were visible throughout the nodule after transcatheter arterial chemoembolization. For these nodules, radiofrequency ablation was performed after ferucarbotran administration. We then performed T2-weighted MRI after 1 week and enhanced CT after 1 month. T2-weighted MRI demonstrated the ablative margin as a low-intensity rim. We classified the margin into three grades; margin (+): high-intensity area with a continuous low-intensity rim; margin zero: high-intensity area with a discontinuous low-intensity rim; and margin (−): high-intensity area extending beyond the low-intensity rim. Results: In 28 (86%) of 32 nodules, there was agreement between MRI and CT. The overall agreement between for the two modalities in the assessment of ablative margin was good (κ = 0.759, 95% confidence interval: 0.480–1.000, p < 0.001). In four nodules, ablative margins on MRI were underestimated by one grade compared with CT. Conclusion: MRI using ferucarbotran is less invasive and allows earlier assessment than CT. The MRI technique performed similarly to enhanced CT with iodized oil marking in evaluating the ablative margin after radiofrequency ablation.

  2. [Study of New Micropore RF system on Lesion Formation and Complications].

    Science.gov (United States)

    Song, Yuwen; Xu, Xiulin; Cai, Yameng

    2017-07-30

    To study the safety and effectiveness of a new type of micropore ablation catheter in vitro ablation system, and to provide reference for clinical practice. To evaluate two kinds of catheter in cardiac tissue ablation depth, tissue temperature and thrombosis situation by the same RF system. The power set 25 W, There was no significant difference in ablation depth between the two groups, and no Pop and thrombosis occurred. When the power is more than 40 W, two groups occurred more Pop and thrombosis. When using high power for Cardiac RF ablation, doctors should pay more attention to complications and thrombosis.

  3. Innovative approach for in-vivo ablation validation on multimodal images

    Science.gov (United States)

    Shahin, O.; Karagkounis, G.; Carnegie, D.; Schlaefer, A.; Boctor, E.

    2014-03-01

    Radiofrequency ablation (RFA) is an important therapeutic procedure for small hepatic tumors. To make sure that the target tumor is effectively treated, RFA monitoring is essential. While several imaging modalities can observe the ablation procedure, it is not clear how ablated lesions on the images correspond to actual necroses. This uncertainty contributes to the high local recurrence rates (up to 55%) after radiofrequency ablative therapy. This study investigates a novel approach to correlate images of ablated lesions with actual necroses. We mapped both intraoperative images of the lesion and a slice through the actual necrosis in a common reference frame. An electromagnetic tracking system was used to accurately match lesion slices from different imaging modalities. To minimize the liver deformation effect, the tracking reference frame was defined inside the tissue by anchoring an electromagnetic sensor adjacent to the lesion. A validation test was performed using a phantom and proved that the end-to-end accuracy of the approach was within 2mm. In an in-vivo experiment, intraoperative magnetic resonance imaging (MRI) and ultrasound (US) ablation images were correlated to gross and histopathology. The results indicate that the proposed method can accurately correlate invivo ablations on different modalities. Ultimately, this will improve the interpretation of the ablation monitoring and reduce the recurrence rates associated with RFA.

  4. Posibilities of cardiac pacemaker use in paroxsysmal atrial fibrilation

    Directory of Open Access Journals (Sweden)

    Borut Kamenik

    2005-12-01

    Full Text Available Background: Prevention of atrial fibrillation is a big therapeutic challenge because of all known negative consequences of this the most frequent cardiac arrhythmia. Numerous of clinical studies showed bad control or ineffectiveness of antiarhythmic drugs. Nonfarmakological therapies like surgical treatment, radiofrequency ablation and atrial pacing are being tested. Effectiveness of atrial pacing in prevention of paroxysmal artial fibrillation has been documented in numerous prospective studies and is effective for a long time interval, but only for patients with bradicardic underlying cardiac rhythm. In Normocardic rhythm or normal AV conduction the effective Atrial fibrillation prevention was not proven. The mechanism of action is based on premature atrial complex suppression, reduction of dispersion of refractoriness after short-long cycles and reduction of interatrial conduction delay. The atrial stimulation site or multi-site atrial pacing could be effective in AF prevention when interatrial conduction delay is present; otherwise the difference is not significant.Conclusions: In bradicardic patient who has frequent paroxysms of atrial fibrillation, regardless if bradycardia is due to ineffective antiarrhythmic drug treathement, implantation of DDDR pacemaker with atrial prevention algorhythm is indicated. If the P-wave duration is >120 milliseconds multi-site atrial pacing or septal atrial pacing should be considered. Pacemaker diagnostic tools could be used for adequate start of anticoagulant therapy and control of effectiveness of anthyarhythmic drug therapy.

  5. Direct His bundle pacing post AVN ablation.

    Science.gov (United States)

    Lakshmanadoss, Umashankar; Aggarwal, Ashim; Huang, David T; Daubert, James P; Shah, Abrar

    2009-08-01

    Atrioventricular nodal (AVN) ablation with concomitant pacemaker implantation is one of the strategies that reduce symptoms in patients with atrial fibrillation (AF). However, the long-term adverse effects of right ventricular (RV) apical pacing have led to the search for alternating sites of pacing. Biventricular pacing produces a significant improvement in functional capacity over RV pacing in patients undergoing AVN ablation. Another alternative site for pacing is direct His bundle to reduce the adverse outcome of RV pacing. Here, we present a case of direct His bundle pacing using steerable lead delivery system in a patient with symptomatic paroxysmal AF with concurrent AVN ablation.

  6. Bipolar radiofrequency ablation of liver metastases during laparotomy. First clinical experiences with a new multipolar ablation concept.

    Science.gov (United States)

    Ritz, Joerg-Peter; Lehmann, Kai S; Reissfelder, Christoph; Albrecht, Thomas; Frericks, Bernd; Zurbuchen, Urte; Buhr, Heinz J

    2006-01-01

    Radiofrequency ablation (RFA) is a promising method for local treatment of liver malignancies. Currently available systems for radiofrequency ablation use monopolar current, which carries the risk of uncontrolled electrical current paths, collateral damages and limited effectiveness. To overcome this problem, we used a newly developed internally cooled bipolar application system in patients with irresectable liver metastases undergoing laparotomy. The aim of this study was to clinically evaluate the safety, feasibility and effectiveness of this new system with a novel multipolar application concept. Patients with a maximum of five liver metastases having a maximum diameter of 5 cm underwent laparotomy and abdominal exploration to control resectability. In cases of irresectability, RFA with the newly developed bipolar application system was performed. Treatment was carried out under ultrasound guidance. Depending on tumour size, shape and location, up to three applicators were simultaneously inserted in or closely around the tumour, never exceeding a maximum probe distance of 3 cm. In the multipolar ablation concept, the current runs alternating between all possible pairs of consecutively activated electrodes with up to 15 possible electrode combinations. Post-operative follow-up was evaluated by CT or MRI controls 24-48 h after RFA and every 3 months. In a total of six patients (four male, two female; 61-68 years), ten metastases (1.0-5.5 cm) were treated with a total of 14 RF applications. In four metastases three probes were used, and in another four and two metastases, two and one probes were used, respectively. During a mean ablation time of 18.8 min (10-31), a mean energy of 48.8 kJ (12-116) for each metastases was applied. No procedure-related complications occurred. The patients were released from the hospital between 7 and 12 days post-intervention (median 9 days). The post-interventional control showed complete tumour ablation in all cases. Bipolar

  7. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  8. Endogenous TSH levels at the time of 131I ablation do not influence ablation success, recurrence-free survival or differentiated thyroid cancer-related mortality

    International Nuclear Information System (INIS)

    Vrachimis, Alexis; Riemann, Burkhard; Maeder, Uwe; Reiners, Christoph; Verburg, Frederik A.

    2016-01-01

    Based on a single older study it is established dogma that TSH levels should be ≥30 mU/l at the time of postoperative 131 I ablation in differentiated thyroid cancer (DTC) patients. We sought to determine whether endogenous TSH levels, i.e. after levothyroxine withdrawal, at the time of ablation influence ablation success rates, recurrence-free survival and DTC-related mortality. A total of 1,873 patients without distant metastases referred for postoperative adjuvant 131 I therapy were retrospectively included from 1991 onwards. Successful ablation was defined as stimulated Tg <1 μg/l. Age, gender and the presence of lymph node metastases were independent determinants of TSH levels at the time of ablation. TSH levels were not significantly related to ablation success rates (p = 0.34), recurrence-free survival (p = 0.29) or DTC -elated mortality (p = 0.82), but established risk factors such as T-stage, lymph node metastases and age were. Ablation was successful in 230 of 275 patients (83.6 %) with TSH <30 mU/l and in 1,359 of 1,598 patients (85.0 %) with TSH ≥30 mU/l. The difference was not significant (p = 0.55). Of the whole group of 1,873 patients, 21 had recurrent disease. There were no significant differences in recurrence rates between patients with TSH <30 mU/l and TSH ≥30 mU/l (p = 0.16). Ten of the 1,873 patients died of DTC. There were no significant differences in DTC-specific survival between patients with TSH <30 mU/l and TSH ≥30 mU/l (p = 0.53). The precise endogenous TSH levels at the time of 131 I ablation are not related to the ablation success rates, recurrence free survival and DTC related mortality. The established dogma that TSH levels need to be ≥30 mU/l at the time of 131 I ablation can be discarded. (orig.)

  9. Diagnostics of laser ablated plasma plumes

    DEFF Research Database (Denmark)

    Amoruso, S.; Toftmann, B.; Schou, Jørgen

    2004-01-01

    The effect of an ambient gas on the expansion dynamics of laser ablated plasmas has been studied for two systems by exploiting different diagnostic techniques. First, the dynamics of a MgB2 laser produced plasma plume in an Ar atmosphere has been investigated by space-and time-resolved optical...... of the laser ablated plasma plume propagation in a background gas. (C) 2003 Elsevier B.V All rights reserved....

  10. Convergent ablation measurements with gas-filled rugby hohlraum on OMEGA

    Science.gov (United States)

    Casner, A.; Jalinaud, T.; Galmiche, D.

    2016-03-01

    Convergent ablation experiments with gas-filled rugby hohlraum were performed for the first time on the OMEGA laser facility. A time resolved 1D streaked radiography of capsule implosion is acquired in the direction perpendicular to hohlraum axis, whereas a 2D gated radiography is acquired at the same time along the hohlraum axis on a x-ray framing camera. The implosion trajectory has been measured for various kinds of uniformly doped ablators, including germanium-doped and silicon-doped polymers (CH), at two different doping fraction (2% and 4% at.). Our experiments aimed also at measuring the implosion performance of laminated capsules. A laminated ablator is constituted by thin alternate layers of un-doped and doped CH. It has been previously shown in planar geometry that laminated ablators could mitigate Rayleigh Taylor growth at ablation front. Our results confirm that the implosion of a capsule constituted with a uniform or laminated ablator behaves similarly, in accordance with post-shot simulations performed with the CEA hydrocode FCI2.

  11. Acute termination of human atrial fibrillation by identification and catheter ablation of localized rotors and sources: first multicenter experience of focal impulse and rotor modulation (FIRM) ablation.

    Science.gov (United States)

    Shivkumar, Kalyanam; Ellenbogen, Kenneth A; Hummel, John D; Miller, John M; Steinberg, Jonathan S

    2012-12-01

    Catheter ablation of atrial fibrillation (AF) currently relies on eliminating triggers, and no reliable method exists to map the arrhythmia itself to identify ablation targets. The aim of this multicenter study was to define the use of Focal Impulse and Rotor Modulation (FIRM) for identifying ablation targets. We prospectively enrolled the first (n = 14, 11 males) consecutive patients undergoing FIRM-guided ablation for persistent (n = 11) and paroxysmal AF at 5 centers. A 64-pole basket catheter was used for panoramic right and left atrial mapping during AF. AF electrograms were analyzed using a novel system to identify sustained rotors (spiral waves), or focal beats (centrifugal activation to surrounding atrium). Ablation was performed first at identified sources. The primary endpoints were acute AF termination or organization (>10% cycle length prolongation). Conventional ablation was performed only after FIRM-guided ablation. Twelve out of 14 cases were mapped. AF sources were demonstrated in all patients (average of 1.9 ± 0.8 per patient). Sources were left atrial in 18 cases, and right atrial in 5 cases, and 21/23 were rotors. FIRM-guided ablation achieved the acute endpoint in all patients, consisting of AF termination in n = 8 (4.9 ± 3.9 minutes at the primary source), and organization in n = 4. Total FIRM time for all patients was 12.3 ± 8.6 minutes. FIRM-guided ablation revealed localized AF rotors/focal sources in patients with paroxysmal, persistent and longstanding persistent AF. Brief targeted FIRM-guided ablation at a priori identified sites terminated or substantially organized AF in all cases prior to any other ablation. © 2012 Wiley Periodicals, Inc.

  12. Ablative thermal protection systems

    International Nuclear Information System (INIS)

    Vaniman, J.; Fisher, R.; Wojciechowski, C.; Dean, W.

    1983-01-01

    The procedures used to establish the TPS (thermal protection system) design of the SRB (solid rocket booster) element of the Space Shuttle vehicle are discussed. A final evaluation of the adequacy of this design will be made from data obtained from the first five Shuttle flights. Temperature sensors installed at selected locations on the SRB structure covered by the TPS give information as a function of time throughout the flight. Anomalies are to be investigated and computer design thermal models adjusted if required. In addition, the actual TPS ablator material loss is to be measured after each flight and compared with analytically determined losses. The analytical methods of predicting ablator performance are surveyed. 5 references

  13. Case Experience of Radiofrequency Ablation for Benign Thyroid Nodules: From an Ex Vivo Animal Study to an Initial Ablation in Taiwan

    Directory of Open Access Journals (Sweden)

    Ming-Tsang Lee

    2016-03-01

    Full Text Available Radiofrequency ablation (RFA is a minimally invasive technique, used with ultrasound or computed tomography guidance, which can produce tissue coagulation necrosis in various kinds of tumors in the human body. In the past 10 years, numerous studies about RFA in benign thyroid nodules have been published. Reviewing these studies, we noticed that the effectiveness of ablation was higher when it was performed with the “moving-shot technique” via an internally cooled electrode. A consensus statement published from the Korean Society of Radiology also suggested the moving-shot technique as a standard ablation procedure for benign thyroid nodule ablation in Korea. In Taiwan, most symptomatic benign nodules are currently treated with surgical removal. RFA for mass lesions is primarily performed for the treatment of metastatic hepatic tumors. In our case, we have attempted to introduce RFA for benign thyroid nodules in Taiwan. Because endocrinologists in Taiwan were not familiar with this technique, we adopted a stepwise approach in learning how to perform RFA. We conducted ex vivo animal ablation exercises to gain experience in setting the radiofrequency generator for the right ablation mode and appropriate power output. The thyroid nodule volume reduction rate after 1 year of follow up was approximately 50% in this case. The most important thing we learned from this trial is that we confirmed the safety of thyroid nodule ablation. To the best of our knowledge, this is the first reported study of RFA of a thyroid nodule in Taiwan.

  14. Radiofrequency ablation of hepatic metastasis: Results of treatment in forty patients

    Directory of Open Access Journals (Sweden)

    Rath G

    2008-01-01

    Full Text Available Aim: To evaluate the local control of hepatic metastasis with radiofrequency ablation treatment. Materials and Methods: We did a retrospective analysis in 40 patients treated with radiofrequency ablation for hepatic metastasis. The tumors ablated included up to two metastatic liver lesions, with primaries in breast, gastrointestinal tract, cervix, etc. Radiofrequency ablation was performed under general anesthesia in all cases, using ultrasound guidance. Radionics Cool-Tip RF System was used to deliver the treatment. Results: The median age of patients treated was 49 years. There were 13 female and 27 male patients. The median tumor size ablated was 1.5 cm (0.75-4.0 cm. A total of 52 radiofrequency ablation cycles were delivered. Successful ablation was achieved in all patients with hepatic metastasis less than 3 cm in size. Pain was the most common complication seen (75%. One patients developed skin burns. At 2-year follow-up 7.5% of patients had locally recurrent disease. Conclusions: Radiofrequency ablation is a minimally invasive treatment modality. It can be useful in a select group of patients with solitary liver metastasis of less than 3 cm size.

  15. Analysis of plasma-mediated ablation in aqueous tissue

    International Nuclear Information System (INIS)

    Jiao Jian; Guo Zhixiong

    2012-01-01

    Plasma-mediated ablation using ultrafast lasers in transparent media such as aqueous tissues is studied. It is postulated that a critical seed free electron density exists due to the multiphoton ionization in order to trigger the avalanche ionization which causes ablation and during the avalanche ionization process the contribution of laser-induced photon ionization is negligible. Based on this assumption, the ablation process can be treated as two separate processes - the multiphoton and avalanche ionizations - at different time stages; so that an analytical solution to the evolution of plasma formation is obtained for the first time. The analysis is applied to plasma-mediated ablation in corneal epithelium and validated via comparison with experimental data available in the literature. The critical seed free-electron density and the time to initiate the avalanche ionization for sub-picosecond laser pulses are analyzed. It is found that the critical seed free-electron density decreases as the pulse width increases, obeying a t p -5.65 rule. This model is further extended to the estimation of crater size in the ablation of tissue-mimic polydimethylsiloxane (PDMS). The results match well with the available experimental measurements.

  16. Statistics on the use of cardiac electronic devices and electrophysiological procedures in the European Society of Cardiology countries: 2014 report from the European Heart Rhythm Association.

    Science.gov (United States)

    Raatikainen, M J Pekka; Arnar, David O; Zeppenfeld, Katja; Merino, Jose Luis; Levya, Francisco; Hindriks, Gerhardt; Kuck, Karl-Heinz

    2015-01-01

    There has been large variations in the use of invasive electrophysiological therapies in the member countries of the European Society of Cardiology (ESC). The aim of this analysis was to provide comprehensive information on cardiac implantable electronic device (CIED) and catheter ablation therapy trends in the ESC countries over the last five years. The European Heart Rhythm Association (EHRA) has collected data on CIED and catheter ablation therapy since 2008. Last year 49 of the 56 ESC member countries provided data for the EHRA White Book. This analysis is based on the current and previous editions of the EHRA White Book. Data on procedure rates together with information on economic aspects, local reimbursement systems and training activities are presented for each ESC country and the five geographical ESC regions. In 2013, the electrophysiological procedure rates per million population were highest in Western Europe followed by the Southern and Northern European countries. The CIED implantation and catheter ablation rate was lowest in the Eastern European and in the non-European ESC countries, respectively. However, in some Eastern European countries with relative low gross domestic product procedure rates exceeded those of some wealthier Western countries, suggesting that economic resources are not the only driver for utilization of arrhythmia therapies. These statistics indicate that despite significant improvements, there still is considerable heterogeneity in the availability of arrhythmia therapies across the ESC area. Hopefully, these data will help identify areas for improvement and guide future activities in cardiac arrhythmia management. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  17. Effect of Radiofrequency Endometrial Ablation on Dysmenorrhea.

    Science.gov (United States)

    Wyatt, Sabrina N; Banahan, Taylor; Tang, Ying; Nadendla, Kavita; Szychowski, Jeff M; Jenkins, Todd R

    To examine rates of dysmenorrhea after radiofrequency endometrial ablation in patients with and without known dysmenorrhea symptoms prior to the procedure in a diverse population. Retrospective cohort study (Canadian Task Force classification II-2). Academic gynecology practice. A total of 307 women underwent endometrial ablation between 2007 and 2013 at our institution. Patients who had preoperative and postoperative pain symptom assessments as well as a description of pain timing recorded were included in our analysis. Exclusion criteria were age dysmenorrhea was evaluated. Demographic information and other outcome variables were used to evaluate factors associated with resolution of dysmenorrhea. A total of 307 patients who underwent radiofrequency endometrial ablation were identified. After exclusions, 296 charts were examined, and 144 patients met our enrollment criteria. The mean age of the study cohort was 45.4 ± 6.2 years; 57 patients (40%) were African American, 16 (11%) had a body mass index (BMI) > 40, and 41 (29%) were of normal weight. Preoperative dysmenorrhea was reported by 100 patients (69%); 48 of these patients (48%) experienced resolution of symptoms postoperatively. Only 3 of the 44 patients (7%) without preoperative dysmenorrhea reported new-onset dysmenorrhea postoperatively. Significantly fewer patients had dysmenorrhea after compared to before radiofrequency ablation (55 of 144 [38%] vs 100 of 144 [69%]; p dysmenorrhea after ablation was associated with reduction in bleeding volume (p = .048) but not with a reduction in frequency of bleeding (p = .12). Approximately one-half of women who undergo radiofrequency endometrial ablation to treat heavy menstrual bleeding who also have preoperative dysmenorrhea exhibit documented pain resolution after the procedure. Resolution of dysmenorrhea is more likely if menstrual flow volume is decreased postprocedure. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  18. Testing and evaluation of light ablation decontamination

    International Nuclear Information System (INIS)

    Demmer, R.L.; Ferguson, R.L.

    1994-10-01

    This report details the testing and evaluation of light ablation decontamination. It details WINCO contracted research and application of light ablation efforts by Ames Laboratory. Tests were conducted with SIMCON (simulated contamination) coupons and REALCON (actual radioactive metal coupons) under controlled conditions to compare cleaning effectiveness, speed and application to plant process type equipment

  19. Ablative Laser Propulsion: An Update, Part I

    International Nuclear Information System (INIS)

    Pakhomov, Andrew V.; Cohen, Timothy; Lin Jun; Thompson, M. Shane; Herren, Kenneth A.

    2004-01-01

    This paper presents an updated review of studies on Ablative Laser Propulsion conducted by the Laser Propulsion Group (LPG) at the University of Alabama in Huntsville. In particular, we describe the newest results of our experimental study of specific impulses and coupling coefficients achieved by double-pulsed ablation of graphite, aluminum, copper and lead targets

  20. Organized Atrial Tachycardias after Atrial Fibrillation Ablation

    Science.gov (United States)

    Castrejón-Castrejón, Sergio; Ortega, Marta; Pérez-Silva, Armando; Doiny, David; Estrada, Alejandro; Filgueiras, David; López-Sendón, José L.; Merino, José L.

    2011-01-01

    The efficacy of catheter-based ablation techniques to treat atrial fibrillation is limited not only by recurrences of this arrhythmia but also, and not less importantly, by new-onset organized atrial tachycardias. The incidence of such tachycardias depends on the type and duration of the baseline atrial fibrillation and specially on the ablation technique which was used during the index procedure. It has been repeatedly reported that the more extensive the left atrial surface ablated, the higher the incidence of organized atrial tachycardias. The exact origin of the pathologic substrate of these trachycardias is not fully understood and may result from the interaction between preexistent regions with abnormal electrical properties and the new ones resultant from radiofrequency delivery. From a clinical point of view these atrial tachycardias tend to remit after a variable time but in some cases are responsible for significant symptoms. A precise knowledge of the most frequent types of these arrhythmias, of their mechanisms and components is necessary for a thorough electrophysiologic characterization if a new ablation procedure is required. PMID:21941669