WorldWideScience

Sample records for traditional tape libraries

  1. DICOM implementation on online tape library storage system

    Science.gov (United States)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  2. Award of two contracts for the renting of magnetic tape drives and tape libraries for LHC data storage and the purchase of the associated tape cartridges

    CERN Document Server

    2005-01-01

    This document concerns the award of two contracts for the renting and possible subsequent purchase of magnetic tape drives and tape libraries for LHC data storage. The Finance Committee is invited to agree to the procedure described in section 3 of this document for the evaluation and possible subsequent purchase of tape drives and tape libraries for the storage of data from the LHC experiments. Subject to approval of this procedure, the Finance Committee is further invited to approve the negotiation of a contract for the renting of tape drives and tape libraries for evaluation purposes from IBM, for an amount of 579 707 Swiss francs, and from StorageTek, for an amount of 472 297 Swiss francs, during the period January 2006 â?" March 2007, plus the purchase of the associated tape cartridges for amounts of 202 500 Swiss francs and 284 748 Swiss francs respectively. The Finance Committee will be informed of the results of the evaluation by the end of 2006 and, subject to the outcome, will be invited to approve...

  3. Computer tape library for collective dose assessments in the European Community

    International Nuclear Information System (INIS)

    Jones, J.A.; Kelly, G.N.

    1981-01-01

    A computer tape library has been established which can readily be applied to enable calculations to be made of the collective dose to the population of the European Community from radioactive effluent discharges within the EC. The background to the development of the tape library and details of its contents, method of application and availability are summarised in this note. (author)

  4. The four silo STK Powderhorn Tape Library

    CERN Multimedia

    Patrice Loïez

    2001-01-01

    A view of the four silo Storage Tek (STK) Powderhorn Tape Library and its control area. Each silo can contain up to 6000 storage slots with cartridges of 10, 20, 25 or 50 GB capacity, reaching a data transfer rate of up to 12 Mbytes/sec. This will form part of the Grid system that will process the huge amounts of data produced at the LHC.

  5. Robotic tape library system level testing at NSA: Present and planned

    Science.gov (United States)

    Shields, Michael F.

    1994-01-01

    In the present of declining Defense budgets, increased pressure has been placed on the DOD to utilize Commercial Off the Shelf (COTS) solutions to incrementally solve a wide variety of our computer processing requirements. With the rapid growth in processing power, significant expansion of high performance networking, and the increased complexity of applications data sets, the requirement for high performance, large capacity, reliable and secure, and most of all affordable robotic tape storage libraries has greatly increased. Additionally, the migration to a heterogeneous, distributed computing environment has further complicated the problem. With today's open system compute servers approaching yesterday's supercomputer capabilities, the need for affordable, reliable secure Mass Storage Systems (MSS) has taken on an ever increasing importance to our processing center's ability to satisfy operational mission requirements. To that end, NSA has established an in-house capability to acquire, test, and evaluate COTS products. Its goal is to qualify a set of COTS MSS libraries, thereby achieving a modicum of standardization for robotic tape libraries which can satisfy our low, medium, and high performance file and volume serving requirements. In addition, NSA has established relations with other Government Agencies to complete this in-house effort and to maximize our research, testing, and evaluation work. While the preponderance of the effort is focused at the high end of the storage ladder, considerable effort will be extended this year and next at the server class or mid range storage systems.

  6. EDITOR: A programme for editing BCD data on magnetic tape in the format of the U.K.A.E.A. Nuclear Data Library

    International Nuclear Information System (INIS)

    Pope, A.L.

    1965-05-01

    This paper describes the programme EDITOR and gives operating instructions. EDITOR is written in the S2 FORTRAN dialect for the IBM 7030 computer. Its purpose is to prepare data library tapes for the U.K.A.E.A. nuclear data library by copying prescribed data files in BCD from one or more input data tapes, or from card decks, on to a single output tape. The first version of the programme was designed by D. Sams at A.W.R.E. Aldermaston; a number of improvements have been incorporated into the current version. (author)

  7. IBM 3480 tape cartridge

    CERN Multimedia

    1984-01-01

    The 3480 tape format is a magnetic tape data storage format developed by IBM. The cartridge contains a single reel. IBM’s 3480 cartridge tape system sought to replace the traditional reels of magnetic tape in the computer center. Because of their speed, reliability, durability and low media cost, these tapes and tape drives are still in high demand. A hallmark of the genre is transferability. Tapes recorded with one tape drive are generally readable on another drive, even if the tape drives were built by different manufacturers.

  8. StorageTek RedWood SD-3 tape drive

    CERN Multimedia

    1995-01-01

    A helical scan recording drive, with a high-speed rotating head sweeping across the tape every few micrometers. Based on a professional video recording system, modified to be suitable for digital data recording. These are commonly used with large computer systems, typically in conjunction with a robotic tape library.

  9. Gauging User Interest in Non-Traditional Library Resources

    Energy Technology Data Exchange (ETDEWEB)

    Sandberg, Tami; Abbott, Jennifer

    2015-06-23

    The National Renewable Energy Laboratory (NREL) is a government funded research laboratory based in Golden, Colorado. In addition to collecting traditional library resources such as journals, conference proceedings, and print and electronic books, the library also spends a significant portion of its collection development funds on resources not often found in many libraries: technical industry standards (e.g., ISO, IEC, ASTM, IEEE) and energy-related market reports. Assessing user needs for these resources is difficult for a number of reasons, particularly because standardized usage statistics are lacking or non-existent. Standards and market reports are generally costly and include fairly restrictive license agreements, which increase the importance of making informed collection development decisions. This presentation will discuss the NREL Library's current collection assessment and development practices as they relate to these unique resources.

  10. Teaching with MARC Tapes

    Directory of Open Access Journals (Sweden)

    Pauline Atherton

    1970-03-01

    Full Text Available A computer based laboratory for library science students to use in class assignments and for independent projects has been developed and used for one year at Syracuse University. MARC Pilot Project tapes formed the data base. Different computer programs and various samples of the MARC file (48,POO records, approx. were used for search and retrieval operations. Data bases, programs, and seven different class assignments are described and evaluated for their impact on library education in gen- eral and individual students and faculty in particular.

  11. Tape SCSI monitoring and encryption at CERN

    Science.gov (United States)

    Laskaridis, Stefanos; Bahyl, V.; Cano, E.; Leduc, J.; Murray, S.; Cancio, G.; Kruse, D.

    2017-10-01

    CERN currently manages the largest data archive in the HEP domain; over 180PB of custodial data is archived across 7 enterprise tape libraries containing more than 25,000 tapes and using over 100 tape drives. Archival storage at this scale requires a leading edge monitoring infrastructure that acquires live and lifelong metrics from the hardware in order to assess and proactively identify potential drive and media level issues. In addition, protecting the privacy of sensitive archival data is becoming increasingly important and with it the need for a scalable, compute-efficient and cost-effective solution for data encryption. In this paper, we first describe the implementation of acquiring tape medium and drive related metrics reported by the SCSI interface and its integration with our monitoring system. We then address the incorporation of tape drive real-time encryption with dedicated drive hardware into the CASTOR [1] hierarchical mass storage system.

  12. Comparison between Kinesio Taping and a Traditional Physical Therapy Program in Treatment of Nonspecific Low Back Pain.

    Science.gov (United States)

    Kachanathu, Shaji John; Alenazi, Aqeel M; Seif, Hamada Eid; Hafez, Ashraf Ramadan; Alroumim, Meshari Abdulmohsen

    2014-08-01

    [Purpose] Nonspecific low back pain (NSLBP) is a very common but largely self-limiting condition. Several types of tape and their associated application methods are available for different conditions. The aim of the present study was to observe the effect of Kinesio taping (KT) compared with traditional management of NSLBP. [Subjects and Methods] Forty male and female patients with a mean age of 34.8±7.54 years were randomly divided into two groups; group 1 (n=20) which underwent conventional physical therapy with KT, and group 2 (n=20), which underwent only conventional physical therapy. The intervention sessions for both groups were three times per week for four weeks. Outcomes were assessed for activities of daily living (ADL) using the Roland-Morris Disability Questionnaire, pain severity using a visual analogue scale, and ranges of motion (ROMs) of trunk flexion and extension using the modified Schober's test. [Results] Significant differences in measures of pain, ADL, and trunk flexion and extension ROMs were observed post intervention within each group. In comparison, there were no significant differences in measures of pain, ADL, and trunk flexion and extension ROMs post intervention between groups. [Conclusion] A physical therapy program involving strengthening exercises for abdominal muscles and stretching exercises for back, hamstring, and iliopsoas muscles with or without Kinesio taping was beneficial in the treatment of chronic low back pain.

  13. Eliminating traditional reference services in an academic health sciences library: a case study

    Science.gov (United States)

    Schulte, Stephanie J

    2011-01-01

    Question: How were traditional librarian reference desk services successfully eliminated at one health sciences library? Setting: The analysis was done at an academic health sciences library at a major research university. Method: A gap analysis was performed, evaluating changes in the first eleven months through analysis of reference transaction and instructional session data. Main Results: Substantial increases were seen in the overall number of specialized reference transactions and those conducted by librarians lasting more than thirty minutes. The number of reference transactions overall increased after implementing the new model. Several new small-scale instructional initiatives began, though perhaps not directly related to the new model. Conclusion: Traditional reference desk services were eliminated at one academic health sciences library without negative impact on reference and instructional statistics. Eliminating ties to the confines of the physical library due to staffing reference desk hours removed one significant barrier to a more proactive liaison program. PMID:22022221

  14. NDS multigroup cross section libraries

    International Nuclear Information System (INIS)

    DayDay, N.

    1981-12-01

    A summary description and documentation of the multigroup cross section libraries which exist at the IAEA Nuclear Data Section are given in this report. The libraries listed are available either on tape or in printed form. (author)

  15. Interlibrary loan in primary access libraries: challenging the traditional view.

    Science.gov (United States)

    Dudden, R F; Coldren, S; Condon, J E; Katsh, S; Reiter, C M; Roth, P L

    2000-10-01

    Primary access libraries serve as the foundation of the National Network of Libraries of Medicine (NN/LM) interlibrary loan (ILL) hierarchy, yet few published reports directly address the important role these libraries play in the ILL system. This may reflect the traditional view that small, primary access libraries are largely users of ILL, rather than important contributors to the effectiveness and efficiency of the national ILL system. This study was undertaken to test several commonly held beliefs regarding ILL system use by primary access libraries. Three hypotheses were developed. HI: Colorado and Wyoming primary access libraries comply with the recommended ILL guideline of adhering to a hierarchical structure, emphasizing local borrowing. H2: The closures of two Colorado Council of Medical Librarians (CCML) primary access libraries in 1996 resulted in twenty-three Colorado primary access libraries' borrowing more from their state resource library in 1997. H3: The number of subscriptions held by Colorado and Wyoming primary access libraries is positively correlated with the number of items they loan and negatively correlated with the number of items they borrow. The hypotheses were tested using the 1992 and 1997 DOCLINE and OCLC data of fifty-four health sciences libraries, including fifty primary access libraries, two state resource libraries, and two general academic libraries in Colorado and Wyoming. The ILL data were obtained electronically and analyzed using Microsoft Word 98, Microsoft Excel 98, and JMP 3.2.2. CCML primary access libraries comply with the recommended guideline to emphasize local borrowing by supplying each other with the majority of their ILLs, instead of overburdening libraries located at higher levels in the ILL hierarchy (H1). The closures of two CCML primary access libraries appear to have affected the entire ILL system, resulting in a greater volume of ILL activity for the state resource library and other DOCLINE libraries higher

  16. ENDF/B-6 decay data library

    International Nuclear Information System (INIS)

    1992-01-01

    This document summarizes the contents of the nuclear decay data library of ENDF/B-6, the U.S. Evaluated Nuclear Data Library. The data are in ENDF-6 format. A copy of the library is available on magnetic tape from the IAEA Nuclear Data Section, free of charge, upon request. (author)

  17. Effect of kinesio-taping on ankle joint stability

    Directory of Open Access Journals (Sweden)

    Mervat A. Mohamed

    2016-05-01

    Full Text Available Ankle Instability is characterized by recurrent giving way and often develops after repeated lateral ankle sprains. Kinesiotape is more elastic than traditional athletic tape and is becoming increasingly popular. It is reported to decrease pain, improve muscle function, circulation and proprioception, however, research examining the effects of Kinesiotape in ankle instability is limited. The objective of this study was to determine if applying Kinesiotape to unstable ankle may improve performance in the Star Excursion Balance Test (SEBT, which has been shown to be a sensitive and reliable measure for quantifying dynamic balance. Thirty subjects with first degree ankle sprain were participated in this study. SEBT was used to test the subject dynamic balance under three conditions; without taping, with white athletic tape and with kinesiotape. One way repeated measure ANOVA using Greenhouse-Geisser corrections were conducted to evaluate differences in SEBT for the three conditions. Pairwise comparison of the outcome measures in the three occasions (without taping, with athletic taping, and with kinesio taping revealed statistically significant differences of all outcomes between occasion 1 (without taping and occasion 2 (with athletic taping favoring the athletic taping (p < 0.05. Also, a statistically significant difference between occasion 1 (without taping and occasion 3 (with kinesio taping were found (p < 0.05 favoring kinesio taping. Moreover, pairwise comparison of the ankle stability outcomes using athletic taping versus kinesio taping indicated a statistically significant difference (p < 0.05 in favor of kinesio taping measures. Conclusion: kinesiotape has superior effect than athletic tape in patients with first degree ankle sprain and can be used safely for improving ankle joint stability.

  18. A program for the automatic request of magnetic tapes filing and reading of its contents. Processor Pcinta

    International Nuclear Information System (INIS)

    Casado, J.; Gomez, J.

    1983-01-01

    It is described how to run a program processor (Pcinta) that automatically supplies, from a tape-library, the magnetic tapes requested by the user and allows the filing and the reading of the contents (recording mode, files information type and files name). (author)

  19. The WIMS 69-group library tape 166259

    International Nuclear Information System (INIS)

    Taubman, C.J.

    1975-07-01

    This note describes the contents of the WIMS 69-group library, and includes a list of nuclides with details of data file or other source of data, resonance tabulations and thermal scattering models, and a list and details of resonance tabulations. Also included are condensation spectra used to obtain group cross-sections in fast energy range, group energy boundaries, and burn-up details, including fuel and fission product burn-up chains, fission product yields and energy release data. A fission spectrum for the 69-group library is given together with a lambda and sigma p values used in the calculation of resonance cross-sections, and 2200 m/sec absorption cross-sections and resonance absorption integrals. (U.K.)

  20. BROND: USSR Evaluated Neutron Data Library

    International Nuclear Information System (INIS)

    Manokhin, V.N.; Lemmel, H.D.; McLaughlin, P.K.

    1989-10-01

    BROND, the USSR computerized data library for evaluated neutron reaction data was released in 1987/1989. Upon request it is available on magnetic tape, costfree, from the IAEA Nuclear Data Section. This document describes the contents of this library in the versions BROND-NDS1 and BROND-NDS2. (author). 16 refs

  1. Tape edge study in a linear tape drive with single-flanged guides

    International Nuclear Information System (INIS)

    Goldade, A.V.; Bhushan, Bharat

    2004-01-01

    Improved tape guiding and tape dimensional stability are essential for magnetic tape linear recoding formats to take advantage of vastly increased track density and thereby achieve higher storage capacities. Tape guiding is dependent on numerous parameters, such as type of the guides and tape path geometry, quality of virgin tape edge, drive operating parameters (e.g., tape speed and tape tension), mechanical properties of the tape, and tape geometry (e.g., cupping and curvature). The objective of the present study is to evaluate guiding and tribological performance of single-flanged guides with porous air bearings in a linear tape drive. A comparison of guiding performance of the dual flanged stationary guides and single-flanged guides with porous air bearings is performed. The effect of tape path geometry, drive operating conditions (speed and tension) and tape edge quality of factory-slit tapes on tape guiding are evaluated during short-term tests. A lateral force measurement technique is used to measure the force exerted by the tape edge on the guide flange. A technique for the lateral tape motion measurement is used to study the effect of continuous sliding on tape guiding. Wear tests up to 5000 cycles are conducted and coefficient of friction and lateral tape motion are monitored to study the effect of drive operating conditions (speed and tension), edge quality of factory-slit tapes and tape thickness on tape guiding. Optical microscopy, atomic force microscopy and scanning electron microscopy are employed to study and quantify the quality of tape edge

  2. BROND. USSR Evaluated Neutron Data Library

    International Nuclear Information System (INIS)

    Manokhin, V.N.

    1990-09-01

    BROND, the USSR computerized data library for evaluated neutron reaction data was released in 1987/1990. Upon request it is available on magnetic tape, costfree, from the IAEA Nuclear Data Section. This document describes the contents of this library in the versions BROND-NDS1 and BROND-NDS2, BROND-NDS3, BROND-NDS4. (author). 16 refs

  3. BROND: USSR evaluated neutron data library

    International Nuclear Information System (INIS)

    Manokhin, V.N.

    1991-03-01

    BROND, the USSR computerized data library for evaluated neutron reaction data was released in 1987/1990. Upon request it is available on magnetic tape, costfree, from the IAEA Nuclear Data Section. This document describes the contents of this library in the four supplements BROND-NDS1, BROND-NDS2, BROND-NDS3, BROND-NDS4. (author). 16 refs

  4. Enriching Traditional Cataloging for Improved Access to Information:Library of Congress Tables of Contents Projects

    Directory of Open Access Journals (Sweden)

    John D. Byrum Jr.

    2006-03-01

    Full Text Available Traditionally, standard catalog records have provided bibliographic data that mostly address the basic features of library resources. At the same time, catalogs have offered access to these records through a limited array of names, titles, series, subject headings, class numbers, and a relatively small number of keywords contained within descriptions. Today’s catalog users expect access to information well beyond what can be offered by traditional approaches to bibliographic description and access. By pursuing a suite of projects, the Library of Congress (LC has responded to the challenge of enticing patrons to continue to include the online catalog among the tools they use for information retrieval. Drawing extensively on the power of automation, staff of LC’s Bibliographic Enrichment Advisory Team (BEAT have created and implemented a variety of initiatives to link researchers, catalogs, and Web resources; increase the content of the catalog record; and link the catalog to electronic resources. BEAT’s ongoing work demonstrates how, in the electronic era, it is possible to provide new and improved ways to capitalize on traditional services in the digital age. This paper will illustrate these points by focusing on BEAT’s tables of contents projects to demonstrate how library automation can make significant bibliographic enhancement efforts quick, easy, and affordable to achieve.

  5. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    OpenAIRE

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-01

    Background It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). Material/Methods Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin ...

  6. SPOTS4. Group data library and computer code, preparing ENDF/B-4 data for input to LEOPARD

    International Nuclear Information System (INIS)

    Kim, J.D.; Lee, J.T.

    1981-09-01

    The magnetic tape SPOTS4 contains in file 1 a data library to be used as input to the SPOTS4 program which is contained in file 2. The data library is based on ENDF/B-4 and consists of two parts in TEMPEST format (246 groups) and MUFT format (54 groups) respectively. From this library the SPOTS4 program produces a 172 + 54 group library for LEOPARD input. A copy of the magnetic tape is available from the IAEA Nuclear Data Section. (author)

  7. Tape transport mechanism

    International Nuclear Information System (INIS)

    Groh, E.F.; McDowell, W.; Modjeski, N.S.; Keefe, D.J.; Groer, P.

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer

  8. JENDL-3. The Japanese evaluated nuclear data library

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1992-01-01

    This document summarizes the contents of JENDL-3.1, the Japanese evaluated data library for neutron nuclear data, released in 1989 and revised in Dec. 1990. It also summarizes the JENDL-3 fission-products cross-section data library released in 1990. The entire library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section free of charge. (author)

  9. Systematic Review of the Effect of Taping Techniques on Patellofemoral Pain Syndrome.

    Science.gov (United States)

    Logan, Catherine A; Bhashyam, Abhiram R; Tisosky, Ashley J; Haber, Daniel B; Jorgensen, Anna; Roy, Adam; Provencher, Matthew T

    ] vs 14.1 [taping alone]). This systematic review supports knee taping only as an adjunct to traditional exercise therapy for PFPS; however, it does not support taping in isolation.

  10. ENDF/B-6 Photon Atomic Interaction Data Library

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1990-09-01

    The ENDF/B-6 version of the Photo-Atomic Interaction Data Library of the Livermore Evaluated Photon Data Library (EPDL) contains pair and triplet cross-sections, photoelectric cross-sections, atom form factors, coherent scattering cross-sections and some other data for all the elements from Z=1 to 100. The data library is available on magnetic tape costfree from the IAEA Nuclear Data Section. The library supersedes the earlier photo-atomic data library by the US Radiation Shielding Information Center RSIC that was included in the data libraries ENDF/B-5 and JEF-1. (author). Refs, figs and tabs

  11. BROND-2. USSR Evaluated Neutron Data Library

    International Nuclear Information System (INIS)

    Manokhin, V.N.

    1992-01-01

    BROND-2, the USSR computerized data library for evaluated neutron reaction data was released in 1992. Upon request it is available on magnetic tape, costfree, from the IAEA Nuclear Data Section. The Library BROND-2 reported in this document supersedes the earlier versions ''BROND-NDS1'' plus three supplements ''BROND-NDS2'', ''BROND-NDS3'', ''BROND-NDS4''. 16 refs

  12. Tape dig selv!

    DEFF Research Database (Denmark)

    Andersen, Bente Annie Sørine; Neergaard, Christian; Seest, Kristian

    Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives......Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives...

  13. Changing Traditions: Automation and the Oxford College Libraries.

    Science.gov (United States)

    Bell, Suzanne

    1990-01-01

    Discussion of automation in the Oxford College Libraries (England) begins with background on the university library system, which consists of numerous independent libraries. Centralized and decentralized automation activities are described, and hardware and software for the microcomputer-based system at the University College Library are…

  14. EADL: Evaluated Atomic Data Library of the Lawrence Livermore National Laboratory, USA. Summary documentation

    International Nuclear Information System (INIS)

    Lemmel, H.D.; Perkins, S.T.; Cullen, D.E.; Chen, M.H.; Hubbell, J.H.; Rathkopf, J.; Scofield, J.

    1994-01-01

    A brief summary documentation of the LLNL Evaluated Atomic Data Library EADL is given. The data library is available from the IAEA Nuclear Data Section on magnetic tape, costfree, upon request. (author)

  15. Modern Italian libraries – between tradition and modernity

    Directory of Open Access Journals (Sweden)

    Kinga Adamiak

    2011-01-01

    Full Text Available For centuries, lands currently belonging to the Republic of Italy boasted the greatest and the most illustrious libraries in Europe. From the Middle Ages to Renaissance, they developed extensively and were dominant in the Old World. The present article, however, concentrates on modern Italian libraries and provides an extensive review of their functioning today. The following issues are covered in the discussion: types of libraries and their cooperation, legal circumstances, the activity of national libraries, library associations and their initiatives and projects aimed at utilization of state-of-the-art IT infrastructures in librarianship. The article also emphasizes strong and weak points of Italian librarianship and ponders on the following: What is the role of Italian libraries today when they are evidently past their prime times? Can the libraries in question meet the requirements of modern times?

  16. EEDL. Evaluated Electron Data Library of the Lawrence Livermore National Laboratory, USA. Summary documentation

    Energy Technology Data Exchange (ETDEWEB)

    Lemmel, H D [ed.; Perkins, S T; Cullen, D E; Seltzer, S M

    1994-09-01

    A brief summary documentary of the LLNL Evaluated Electron-Interaction Data Library EEDL is given. The data library is available from the IAEA Nuclear Data Section on magnetic tape, costfree, upon request. (author).

  17. EEDL. Evaluated Electron Data Library of the Lawrence Livermore National Laboratory, USA. Summary documentation

    International Nuclear Information System (INIS)

    Lemmel, H.D.; Perkins, S.T.; Cullen, D.E.; Seltzer, S.M.

    1994-01-01

    A brief summary documentary of the LLNL Evaluated Electron-Interaction Data Library EEDL is given. The data library is available from the IAEA Nuclear Data Section on magnetic tape, costfree, upon request. (author)

  18. BROND: USSR recommended evaluated neutron data library

    International Nuclear Information System (INIS)

    Manokhin, V.N.

    1988-03-01

    BROND is the recommended evaluated data library of the USSR for neutron induced nuclear reactions. It is a computer library recorded on magnetic tape presented in the internationally recommended format ENDF-5. It contains 65 files with recommended data for 65 elements or isotopes. For each file the present report gives a summary documentation on the contents, the evaluation methods and the originators of the files. (author). Refs

  19. SUPLEMENTASI Lactobacillus acidophilus SNP-2 PADA TAPE DAN PENGARUHNYA PADA RELAWAN [Supplementation of Lactocbacillus acidophilus SNP-2 Into Tape and its Effect to the Volunteer

    Directory of Open Access Journals (Sweden)

    Endang S Rahayu1

    2004-08-01

    Full Text Available Functional food is defined as any potentially healthful food or food ingredient that may provide a health benefit beyond the traditional nutrients it contains. Many researches have been conducted on the health benefit of probiotic (life bacterial cells, one of the ingredient of functional foods. One of the potential bacteria used for probiotic agent and also involved in traditional fermented foods are lactic acid bacteria (LAB. Previous research showed that Lactobacillus acidophilus SNP-2 isolated from faecal material of healthy infant is resistant to acid and bile salt, and has an antagonistic effect against several enteric bacterial pathogens. The objective of this research was to study the effect of L. acidophilus SNP-2 as probiotic agent to the health benefits. These bacteria were supplemented into tape ketan (fermented sticky rice, the indigenous Indonesian fermented food. Tape ketan was chosen as the carrier of probiotic biomass based on the high population of LAB in this product, i.e., 1.3 x 108 CFU/g. Addition of L. acidophilus SNP-2 biomass prior to fermentation of tape ketan resulted in a higher total of LAB cells, i.e. 2.1 x 109 CFU/g compared to the amount of 1.5 x 108 CFU/g when the addition was done after fermentation. Consumption of tape ketan containing probiotic agent by the volunteers increased the population of lactobacilli (from 1.7x107 CFU/g to 9.9x107 CFU/g and decreased the population of enterobacteriacea (from 5.4x109 CFU/g to 4.4x108 in their faecal material. This phenomenon revealed that probiotic agent was able to colonize and inhibit the growth of enterobacteriaceae in the gastrointestinal tract. The result implied that tape ketan can be used as a carrier for probiotic agent and it can be categorized as functional food

  20. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    Science.gov (United States)

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-14

    BACKGROUND It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). MATERIAL AND METHODS Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. RESULTS Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. CONCLUSIONS Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow.

  1. Radiographic Outcomes of Postoperative Taping Following Hallux Valgus Correction.

    Science.gov (United States)

    Ponzio, Danielle Y; Pedowitz, David I; Verma, Kushagra; Maltenfort, Mitchell G; Winters, Brian S; Raikin, Steven M

    2015-07-01

    Traditionally, hallux valgus operative correction has been accompanied by serial spica taping of the great toe during the postoperative period. We retrospectively reviewed 187 adult patients who underwent proximal first metatarsal osteotomy with a modified McBride procedure in 2008-2009 (n = 83) and 2011-2012 (n = 104). Postoperatively, to maintain the corrected position of the hallux, patients from 2008 through 2009 underwent weekly spica taping, while patients from 2011 through 2012 utilized a toe separator. The hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured using anteroposterior weight-bearing preoperative, 2-week postoperative non-weight-bearing, and 3-month weight-bearing final follow-up radiographs. A mixed-effects linear regression model identified differences between the treatment groups over time, and a t test compared actual radiographic differences at final follow-up. The mixed-effects model revealed no significant difference in the HVA over time when comparing patients taped to those not taped at the preoperative (33 ± 6 vs 33 ± 6), 2-week postoperative (10 ± 7 vs 9 ± 6), and 3-month follow-up (14 ± 6 vs 11 ± 7) visits (P = .08). At final follow-up, the HVA was lower for the group that was not taped, but the difference (2.5 degrees) was below the minimal clinically important difference (MCID) (P = .015, 95% CI 0.5-4.5). For IMA, there was improved maintenance of correction over time in the patients that were not taped compared to those taped at the preoperative (15 ± 3 vs 15 ± 3), 2-week postoperative (2 ± 2 vs 3 ± 3), and 3-month follow-up (5 ± 4 vs 7 ± 4) visits (P = .002). At final follow-up, the IMA was lower for the group that was not taped, but the difference (1.7 degrees) was below the MCID (P = .004, 95% CI 0.7-2.9). We report no radiographic benefit of postoperative taping after hallux valgus correction. The present study challenges the previous dogma of postoperative spica taping as the protocol is cost and

  2. Libraries for users services in academic libraries

    CERN Document Server

    Alvite, Luisa

    2010-01-01

    This book reviews the quality and evolution of academic library services. It revises service trends offered by academic libraries and the challenge of enhancing traditional ones such as: catalogues, repositories and digital collections, learning resources centres, virtual reference services, information literacy and 2.0 tools.studies the role of the university library in the new educational environment of higher educationrethinks libraries in academic contextredefines roles for academic libraries

  3. Quantification of massively parallel sequencing libraries - a comparative study of eight methods

    DEFF Research Database (Denmark)

    Hussing, Christian; Kampmann, Marie-Louise; Mogensen, Helle Smidt

    2018-01-01

    Quantification of massively parallel sequencing libraries is important for acquisition of monoclonal beads or clusters prior to clonal amplification and to avoid large variations in library coverage when multiple samples are included in one sequencing analysis. No gold standard for quantification...... estimates followed by Qubit and electrophoresis-based instruments (Bioanalyzer, TapeStation, GX Touch, and Fragment Analyzer), while SYBR Green and TaqMan based qPCR assays gave the lowest estimates. qPCR gave more accurate predictions of sequencing coverage than Qubit and TapeStation did. Costs, time......-consumption, workflow simplicity, and ability to quantify multiple samples are discussed. Technical specifications, advantages, and disadvantages of the various methods are pointed out....

  4. ENDF/B-III scattering law library

    International Nuclear Information System (INIS)

    Goulo, V.; Lemmel, H.D.

    1989-12-01

    This library contains scattering law data S(α,β) for 10 materials used for thermal reactor and shielding calculations: H 2 O, D 2 O, Be, BeO, C, CH 2 , C 6 H 6 , UO 2 , ZrH x (for H), ZrH x (for Zr) for temperatures from 296 to 1000 or 1200 deg. K. Data are in ENDF/B-3 format. The library is available from the IAEA Nuclear Data Section on magnetic tape, costfree upon request. (author). Figs and tabs

  5. Setting up and Running a School Library. Information Collection and Exchange Publication No. ED204

    Science.gov (United States)

    Baird, Nicola

    2012-01-01

    This book explains how teachers can set up and run a successful school library. In it you will find advice and information on how to: (1) set up a small library and build bookshelves; (2) select books for your library; (3) make a written record of your school's books, pamphlets and other library stock such as newspapers, magazines, audio tapes and…

  6. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Chihaya, E-mail: chihaya.kurihara@jp.fujikura.com [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka [Kyushu University, 744 Motooka, Nishi-Ku, Fukuoka 819-0395 (Japan)

    2016-11-15

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I{sub c} measurement, we found that our new multi-filamentary tape could provide almost equal I{sub c} compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  7. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    International Nuclear Information System (INIS)

    Kurihara, Chihaya; Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro; Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka

    2016-01-01

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I_c measurement, we found that our new multi-filamentary tape could provide almost equal I_c compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  8. Placement suitability criteria of composite tape for mould surface in automated tape placement

    Directory of Open Access Journals (Sweden)

    Zhang Peng

    2015-10-01

    Full Text Available Automated tape placement is an important automated process used for fabrication of large composite structures in aeronautical industry. The carbon fiber composite parts realized with this process tend to replace the aluminum parts produced by high-speed machining. It is difficult to determine the appropriate width of the composite tape in automated tape placement. Wrinkling will appear in the tape if it does not suit for the mould surface. Thus, this paper deals with establishing placement suitability criteria of the composite tape for the mould surface. With the assumptions for ideal mapping and by applying some principles and theorems of differential geometry, the centerline trajectory of the composite tape is identified to follow the geodesic. The placement suitability of the composite tape is examined on three different types of non-developable mould surfaces and four criteria are derived. The developed criteria have been used to test the deposition process over several mould surfaces and the appropriate width for each mould surface is obtained by referring to these criteria.

  9. Enhancing the low-level tape layer of CERN Tape Archive software

    CERN Document Server

    AUTHOR|(CDS)2160814; Ruse, Laura Cristina; Vasilescu, Laura

    CERN manages the largest scientific data archive in the HEP domain. The archive currently holds over 180 Petabytes, with forecasts of up to 100PB of new data added per year. Considering this numbers, the most cost-effective solution for storage in terms of capacity and maintenance is represented by magnetic tapes. The drawback of this solution is the access time which can raise to several minutes for a series of files. In an environment where very large volumes of physics data are being traded from tape to disk and vice versa, this issue becomes a serious performance bottleneck. This thesis introduces two low-level tape access optimizations: first, adding support for the Recommended Access Order (RAO), a mechanism offered by the tape hardware infrastructure to compute the file order corresponding to the minimum access time. We will present our solution for including RAO in the file retrieval operations in CERN tape archive software in order to benefit from the reduced reading time. The second optimization ...

  10. PRELIMINARY DETERMINATION OF PEDAGOGIC UTILITY OF THE ARCHIVE OF HISPANIC LITERATURE ON TAPE. FINAL REPORT.

    Science.gov (United States)

    CLINE, HOWARD F.

    A STUDY WAS CONDUCTED TO DETERMINE THE POSSIBLE PEDAGOGICAL UTILIZATION OF THE LIBRARY OF CONGRESS ARCHIVE OF HISPANIC LITERATURE ON TAPE WHICH CONTAINS, AS OF JUNE 1962, ORIGINAL RECORDINGS IN SPANISH, PORTUGUESE, CATALAN, AND FRENCH OF THE VOICES OF 218 WRITERS READING SOME 2,800 LITERARY WORKS. PROCEDURES TAKEN TO ENCOURAGE LONG-TERM UTILITY OF…

  11. The Imation 9840 Tape Cartridge

    CERN Multimedia

    It’s a 20 GB uncompressed center-load cartridge used in StorageTek T9840 tape drives. The tape is a Metal Particle (MP) tape suitable for use on all Oracle/Sun/StorageTek 9840 A, B, C and D drives. The 9840 tape has an archival life of 15-30 years.

  12. Forensic utility of the carbon isotope ratio of PVC tape backings

    Science.gov (United States)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  13. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15?h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ank...

  14. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    Science.gov (United States)

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  15. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    Science.gov (United States)

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. E-Library and Traditonal Library Resources Usage: A Comparative ...

    African Journals Online (AJOL)

    A comparative usage of e-library and traditional resources in Nigerian libraries was examined in this study. A descriptive survey method was adopted and a purposive sampling technique was used to select the sample and the process produced 125 academic, research, and public libraries in Nigeria. A total of 116 cases ...

  17. Index of data libraries available on magnetic tape from the IAEA Nuclear Data Section

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1990-01-01

    This document lists more than 80 nuclear data libraries and some atomic data libraries together with references that give more detailed information about these libraries. All data and documentation references are available upon request from the IAEA Nuclear Data Section, free of charge. (author)

  18. Index of data libraries available on magnetic tape from the IAEA Nuclear Data Section

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1991-05-01

    This document lists more than 80 nuclear data libraries and some atomic data libraries together with references that give more detailed information about these libraries. All data and documentation references are available upon request from the IAEA Nuclear Data Section, free of charge. (author)

  19. Index of data libraries available on magnetic tape from the IAEA Nuclear Data Section

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1986-07-01

    This document lists more than 80 nuclear data libraries and some atomic data libraries together with references that give more detailed information about these libraries. All data and documentation references are available upon request from the IAEA Nuclear Data Section, free of charge. (author)

  20. EFFECT OF KINESIO TAPE VERSUS ATHLETIC TAPE ON MYOELECTRIC ACTIVITY OF ANKLE MUSCLES IN PATIENTS WITH CHRONIC ANKLE SPRAIN

    Directory of Open Access Journals (Sweden)

    Asmaa F Abdelmonem

    2018-04-01

    Full Text Available Background: Sprained ankle a common orthopedic injury. The standard treatment for ankle sprains remains nonoperative. Ankle taping was used to protect and prevent ligaments excessive strain. So, the current study aimed at investigating the effect of spa-care Kinesio tape versus standard white athletic tape on myoelectric activities (EMG of ankle evertors (peroneus longus and invertors (tibialis anterior in a chronic ankle sprain. Methods: A convenient sample of 30 patients with a chronic ankle sprain (18 females and 12 males were included in this study. Their mean age ±SD was 24 ±1.2 years. Their height was 175±4.8 cm among men & 163±5.2 cm for females, and weight was 85±5.2 kg for males & 74±5.5 kg for women. It was a within-group design in which the same participant experienced the two types of taping compared to no taping condition. Root mean square (RMS was measured while participants were moving the isokinetic dynamometer at an angular velocity of 120°/sec using concentric contraction mode through full ankle range of motion. The EMG (RMS of evertors and invertors was measured immediately after the three taping ways (no tape, Kinesio tape, and athletic tape with a one-week interval between each taping. Results: Spa-care Kinesiotape significantly reduced evertors and invertors EMG (RMS compared with no tape or athletic tape in patients with chronic ankle sprain. Mean± SD of the evertors was 0.7 (±0.1 for no tape and 0.58 (±0.2 for Kinesio tape. The P value was 0.000 for kinesio tape in evertors compared with no tape. Also, mean± SD of the invertors was 0.87 (±0.23 for no tape, and 0.54 (±0.1 for Kinesio tape and the P value was 0.001 for Kinesio tape in invertors compared with no tape. Conclusion: Spa-care Kinesio tape may be useful for reducing EMG activity of ankle muscles in a chronic ankle sprain.

  1. Flow structure and heat transfer in a square duct fitted with dual/quadruple twisted-tapes: Influence of tape configuration

    International Nuclear Information System (INIS)

    Eiamsa-ard, S.; Changcharoen, W.

    2015-01-01

    Numerical predictions reported of thermohydraulic characteristics of square ducts equipped with dual and quadruple twisted tapes (DTs and QTs) with different configurations. The studied cases include (1) dual co-tapes (Co-DTs), (2) dual counter-tapes (C-DTs), (3) diagonal dual counter-tapes (C-DDTs), (4) diagonal dual co-tapes (Co-DDTs), (5) quadruple co-tapes (Co-QTs), (6) quadruple counter tapes (CC-QTs) and (7) quadruple counter-tapes (PC-QTs). The results of these cases are compared with those of a smooth duct (a duct without tape insert) and also the one with a single tape (ST). The prediction involves using the RNG k-ε turbulent model under constant wall heat flux condition in the turbulent flow regime for the Reynolds number ranging from 6000 to 14000. The prediction indicates that thermohydraulic characteristics in ducts with twisted tape are strongly dependent on number and configuration of tapes. However, the influence of tape number is more significant than that of tape configuration. Heat transfer and friction increase as tape number increases. QTs offer superior heat transfer to DTs but their thermal performance factors are lower. For the tape inserts determined, DTs with diagonal configuration (Co-DDTs and C-DDTs) is the best design as the tapes offer the best thermal performance. The highest thermal performance factors given by Co-DTs, Co-DDTs, C-DTs, C-DDTs, Co-QTs, PC-QTs and CC-QTs, are around 1.21, 1.35, 1.25, 1.38, 1.08, 1.18, and 1.22, respectively

  2. The Development of E-Library at Delta State University Library, Abraka

    African Journals Online (AJOL)

    The study is on the automation of Delta University Library Abraka. The processes involved in the acquisition of information communication technology equipments to complement the traditional Library Services were stated. Major issues discussed include acquisition of computers hardware and library software, telephone ...

  3. Digital tape unit test facility software

    Science.gov (United States)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  4. Tape write-efficiency improvements in CASTOR

    International Nuclear Information System (INIS)

    Murray, S; Bahyl, V; Cancio, G; Cano, E; Lo Presti, G; Lo Re, G; Ponce, S; Kotlyar, V

    2012-01-01

    The CERN Advanced STORage manager (CASTOR) is used to archive to tape the physics data of past and present physics experiments. For reasons of physical storage space, all of the tape resident data in CASTOR are repacked onto higher density tapes approximately every two years. Improving the performance of writing files smaller than 2GB to tape is essential in order to keep the time needed to repack all of the tape resident data within a period of no more than 1 year. This paper reports on the solution to writing efficiently to tape that is currently in its early deployment phases at CERN.

  5. INDL/V (85). IAEA Nuclear Data Library for various neutron data evaluations in ENDF-5 format

    International Nuclear Information System (INIS)

    Lemmel, H.D.; Goulo, V.; McLaughlin, K.; Pronyaev, V.; Schwerer, O.

    1985-06-01

    INDL/V is a computerized library for evaluated neutron reaction data from varying origin compiled in ENDF-5 format. The data are available costfree on magnetic tape from the IAEA Nuclear Data Section. This document summarizes the contents of the library in its version of March 1985. (author)

  6. Growing Competition for Libraries.

    Science.gov (United States)

    Gibbons, Susan

    2001-01-01

    Describes the Questia subscription-based online academic digital books library. Highlights include weaknesses of the collection; what college students want from a library; importance of marketing; competition for traditional academic libraries that may help improve library services; and the ability of Questia to overcome barriers and…

  7. Paper Punch Tape

    CERN Multimedia

    Physicists coded and recorded their programs through series of holes on punch paper tape or on punched cards. It was popular in the 1970s due to its high throughput speed and low cost, paper tape was one of the original data storage methods for computers. Information was encoded in the distinct pattern of holes punched in the paper; the paper itself was oiled to facilitate being run through the reading mechanism and to prevent tears due to brittleness. Though the paper was cheap, it had low storage capacity (only a few dozen kilobytes per roll) and the machinery involved in punching the holes was quite expensive. Higher capacity alternatives, such as magnetic tape, has get developped.

  8. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Wen-Dien Chang

    2015-01-01

    Full Text Available Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS. Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life.

  9. Open archive solutions to traditional archive/library cooperation

    Directory of Open Access Journals (Sweden)

    Donatella Castelli

    2003-09-01

    Full Text Available The diffusion of Internet is changing the role of archives and libraries and it is opening a wide range of new possibilities. The new vision is that in few years it will be possible to cross-access multiple libraries, archives, museums, and data repositories. The implementation of this revolutionary vision requires the solution of a number of technical, organizational, sociological, and economical issues. Recently, the proposal of a new, low cost technical solution for open repositories of pre-print material, the Open Archives Initiative Protocol for Metadata Harvesting ( OAI-PMH, has greatly stimulated the discussion about these issues in many application frameworks. This paper overviews the status of this discussion in the library and conventional archives frameworks.

  10. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    Directory of Open Access Journals (Sweden)

    Biju Chetri

    2016-04-01

    Full Text Available Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected. The subjects were randomly divided into two groups i.e. Group A and Group B. Group A received taping, iontophoresis with plantar fascia stretching. Group B received taping and plantar fascia stretching. A total of 6 treatment sessions were given on alternate days over a period of two weeks for both the groups. Results: VAS and FFI scores across baseline and post intervention showed a significant improvement statistically in their mean scores between Groups A and B (P<0.05. Between group comparison of VAS and FFI scores, it showed that subject treated with Iontophoresis in combination with taping and plantar fascia stretch (Group A had significant improvement in VAS and functional ability when compared to subjects treated with taping and plantar fascia stretching alone (Group B. Conclusion: Iontophoresis along with Taping and plantar fascia stretching gave an additional benefit when compared with Taping and plantar fascia stretching alone in reducing pain and improving function in plantar fasciitis.

  11. INDL/V. IAEA Nuclear Data Library for various neutron data evaluations in ENDF/B-5 format

    International Nuclear Information System (INIS)

    Pronyaev, V.; Cullen, D.; Lemmel, H.D.; McLaughlin, K.; Schwerer, O.

    1982-05-01

    INDL/V is a computerized library for evaluated neutron reaction data of varying origin compiled in ENDF/B-5 format. The data are available costfree on magnetic tape from the IAEA Nuclear Data Section. This document summarizes the contents of the library, including graphical plots of all cross-section data. (author)

  12. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the S...

  13. The Oral History Program: II. Personal views of health sciences librarianship and the Medical Library Association.

    Science.gov (United States)

    McKenzie, D; Pifalo, V

    1998-07-01

    The Medical Library Association Oral History Program uses accepted oral history techniques to collect and preserve interviews with members. The original taped interviews and transcripts are kept in the Medical Library Association archives and made available for research purposes; edited copies of the interviews are distributed through the National Network of Libraries of Medicine, and members are encouraged to borrow and read the histories. Summaries of forty-three interviews provide personal views on health sciences librarianship and the Medical Library Association.

  14. Application for the Tape Station

    CERN Document Server

    Solero, A

    2003-01-01

    The Tape Station is used as an Isolde facility to observe the variations of intensity and the lifespan of certain isotopes. A Siemens Simatic FM-352-5 module controls the Tape Station in a PLC system then a DSC controls the PLC, which will be controlled the Tape station program. During the Isolde consolidation project, the Tape Station has been rebuilt, and the control system has been fully integrated in the PS control. Finally, a new application has been written in JAVA Development kit 1.4 and the PS Java environment. The main purpose of this note is to explain how to use this program.

  15. Digital library initiative in an Indian research library: an experience report

    International Nuclear Information System (INIS)

    Venkadesan, S.; Narayanan, A.

    1999-01-01

    Libraries all over the world are transiting from the traditional print only era to the electronic era. The migration to an electronic library involves the understanding of several issues and requirements at the planning stage itself. This paper describes the various aspects of building a digital library system. Experience of implementing certain strategies in the IGCAR library is discussed in detail. The components of the digital library and the various access levels are discussed with examples. Finally, samples of the IGCAR library web site and the Newsletter web site are shown. (author)

  16. Recommended formulae and formats for a resonance parameter library

    International Nuclear Information System (INIS)

    James, M.F.

    1968-08-01

    It is proposed that a library of neutron resonance parameters be set up, on punched cards and magnetic tape, which will complement the cross section data in the present U.K. Nuclear Data Library. This report gives parametric formulae for the resolved resonance region, based on:- (i) the Breit-Wigner approximation, (ii) other approximations of R-matrix theory and (iii) the formulae of Adler and Adler. In addition, the statistical distributions of the parameters are given. The final section of the report contains the recommended formats for the parameters of the various formulae. (author)

  17. The neutron beam users tape management system

    International Nuclear Information System (INIS)

    Lyall, B.; Johnson, M.W.

    1977-02-01

    Systems are described for dealing with data collected at the High Flux Reactor, Institut Laue-Langevin, Grenoble and brought on magnetic tape to the Neutron Beam Research Unit at the Rutherford Laboratory. The first system, named GNAT, was designed to archive the incoming 800 bpi tapes onto 6250 bpi tapes (to enable them to return to the ILL). The archiving program, besides choosing the archive tapes, keeping a record of the data sets archived, and writing the archive tape, should be able to cope with incoming tapes whose formats are somewhat different from the standard IBM format. The second system, named FONT, was designed to maintain a record of all the tapes in the NBRU's possession, their whereabouts and what data, if any, are on them. (U.K.)

  18. Tape Storage and CRC Protection

    CERN Document Server

    Ha, Karel

    2014-01-01

    Over 100 Petabytes of data is stored on several kind of physical support, namely disks and tapes. Data on any physical support or traveling on a data link (network, fibre channel...) can be subject to silent data corruption. A possible improvement is introducing end-to-end data integrity from the filesystem down to the tape layer. For the tape back-end it can be done by using Logical Block Protection, which computes and compares CRC checksum of every single block of data. During my work, I improved on-the-fly CRC calculation for the tape storage system, which was achieved by introducing a multithreaded implementation - a technique applicable to arbitrary CRC algorithm. Finally, I per...

  19. ANSL-V: ENDF/B-V based multigroup cross-section libraries for Advanced Neutron Source (ANS) reactor studies

    International Nuclear Information System (INIS)

    Ford, W.E. III; Arwood, J.W.; Greene, N.M.; Petrie, L.M.; Primm, R.T. III; Waddell, M.W.; Webster, C.C.; Westfall, R.M.; Wright, R.Q.

    1987-01-01

    Multigroup P3 neutron, P0-P3 secondary gamma ray production (SGRP), and P6 gamma ray interaction (GRI) cross section libraries have been generated to support design work on the Advanced Neutron Source (ANS) reactor. The libraries, designated ANSL-V (Advanced Neutron Source Cross-Section Libraries), are data bases in a format suitable for subsequent generation of problem dependent cross sections. The ANSL-V libraries are available on magnetic tape from the Radiation Shielding Information Center at Oak Ridge National Laboratory

  20. Business planning for digital libraries international approaches

    CERN Document Server

    Collier, Mel

    2010-01-01

    This book brings together international experience of business planning for digital libraries: the business case, the planning processes involved, the costs and benefi ts, practice and standards, and comparison with the traditional library where appropriate. Although there is a vast literature already on other aspects of digital libraries, business planning is a subject that until now has not been systematically integrated in a book.Digital libraries are being created not only by traditional libraries, but by museums, archives, media organizations, and indeed any organization concerned with ma

  1. The alternative library

    OpenAIRE

    Collinson, Timothy; Williams, A.

    2004-01-01

    Much time and effort has been devoted to designing and developing library Web sites that are easy to navigate by both new students and experienced researchers. In a review of the Southampton Institute Library it was decided that in addition to updating the existing homepage an alternative would be offered. Drawing on theory relating to user interface design, learning styles and creative thinking, an Alternative Library navigation system was added to the more traditional library homepage. The ...

  2. Analisis Perilaku Konsumen Proll Tape di Jember

    OpenAIRE

    Kusmiati, Ati; Widjayanti, Lenny; Risaldi, Feri

    2009-01-01

    Proll tape is a agroindustrial product which used agriculture product as a basic material. It is a diversification product from tape and mixed with some flavour. It can be found in the gift store. Proll tape marketing strategic will influence consumer behaviour in the decision buying. Consumer buy proll tape as a gift as beside on their own consumption. Consumer considers proll tape has a good quality so that it can fill consumer needed. Purpose of the research to find out the influence facto...

  3. Archives and library administration divergent traditions and common concerns

    CERN Document Server

    Harworth, New York, NY

    1986-01-01

    This informative volume focuses on the effective management of library archives, presenting perspectives and firsthand accounts from experienced and successful administrators in the field. The contributors examine the differences and similarities in the management of archives and other library/information centers, providing valuable insights into various managment styles, decisions, and planning techniques.

  4. BROND-2.1. Russian Evaluated Neutron Reaction Data Library

    International Nuclear Information System (INIS)

    Manokhin, V.N.

    1993-01-01

    BROND-2, the computerized data library for evaluated neutron reaction data of the Russian Federation was released in 1992 and updated as BROND-2.1. Its content is summarized in this document. Upon request it is available on magnetic tape, cost free, from the IAEA Nuclear Data Section. It is also available within the IAEA online system NDIS. (author)

  5. Superconducting joint of Bi-2223/Ag superconducting tapes by diffusion bonding

    International Nuclear Information System (INIS)

    Guo Wei; Zou Guisheng; Wu Aiping; Wang Yanjun; Bai Hailin; Ren Jialie

    2009-01-01

    61-Filaments Bi-2223/Ag superconducting tapes have been joined by diffusion bonding. The critical currents (I C s) of the joints are obtained by using standard four probe method under no magnetic field in the liquid nitrogen. The microstructures of the joints are evaluated by the electron microscope in electron backscatter diffraction mode and the phase compositions of the superconducting cores of the joint and the original tape are determined by X-ray diffraction (XRD). The results show diffusion bonding is effective bonding technique for HTS tapes, and the bonding time is reduced greatly from hundreds of hours to a few hours, and the bonding pressure also changes from 140-4000 MPa to 3 MPa. Furthermore, the diffusion bonding joints sustain superconducting properties, and the critical current ratios (CCR O ) of the joints are in the range of 35%-80%. Microstructures of the typical joint display a good bonding and some defects existed in traditional method are avoided. XRD results show that the phase compositions of the superconducting cores have no obvious changes before and after diffusion bonding, which offers physical and material bases for high superconducting property of the joints.

  6. Index of Nuclear Data Libraries available from the IAEA Nuclear Data Section

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1994-01-01

    This document lists more than 100 nuclear data libraries together with references that give more detailed information about these libraries. The data libraries include neutron cross-sections, resonance parameters, fission-product yields, nuclear structure and decay data, gamma-rays from radionuclides, data of nuclear reactions induced by charged particles or heavy ions, photonuclear data, photoatomic interaction data, and many others, partly with related data processing computer codes. All data and documentation references are available upon request from the IAEA Nuclear Data Section, free of charge on magnetic tape, PC diskettes, or through the online Nuclear Data Information System (NDIS). (author)

  7. School Libraries and Innovation

    Science.gov (United States)

    McGrath, Kevin G.

    2015-01-01

    School library programs have measured success by improved test scores. But how do next-generation school libraries demonstrate success as they strive to be centers of innovation and creativity? These libraries offer solutions for school leaders who struggle to restructure existing systems built around traditional silos of learning (subjects and…

  8. INDL/A IAEA Nuclear Data Library for evaluated neutron reaction data of actinides

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1982-05-01

    This Library contains evaluations performed by participants of the IAEA Coordinated Research Project on the Intercomparison of Evaluations of Actinide Neutron Nuclear Data. The data are available on magnetic tape, free of charge, from the IAEA Nuclear Data Section. (author)

  9. ENDF/B-5 Fission Products Library 1979

    International Nuclear Information System (INIS)

    Schwerer, O.; Lemmel, H.D.

    1981-10-01

    This document summarizes contents and documentation of the 1979 version of the Fission Products File of the ENDF/B Library maintained by the National Nuclear Data Center (NNDC) at the Brookhaven National Laboratory, USA. This file contains numerical neutron reaction data and decay data for 877 fission product nuclides. The entire file or selective retrievals from it can be obtained on magnetic tape from the IAEA Nuclear Data Section. (author)

  10. Caught (Unfortunately) on Tape

    Science.gov (United States)

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  11. 78 FR 33106 - Certain Automated Media Library Devices; Decision to Modify In Part a Remand Initial...

    Science.gov (United States)

    2013-06-03

    ... Products, Inc., of Irvine, California; Dell Inc. of Round Rock, Texas (``Dell''); and International... qualify as prior art anticipate or, in combination with their associated IBM tape library and/or U.S...

  12. Skin impression with acetate tape in Demodex canis and Scarcoptes scabiei var. vulpes diagnosis

    Directory of Open Access Journals (Sweden)

    D.T. Pereira

    2015-02-01

    Full Text Available This study compares the efficacy of skin impression with acetate tape and the deep skin scraping test to find D. canis and S. scabiei in dogs. During six months, 134 samples were collected by both techniques from 115 dogs treated at the dermatology service of the Veterinary Hospital of the Federal University of Santa Maria (HVU-UFSM. Of these patients, 27 had demodicosis and 12 had scabies. The impression with acetate tape test (ITT was shown to be significantly superior to the deep skin scraping test (DSST in finding D. canis and S. scabiei mites (p = 0.007. Based on our results we could conclude that acetate tape impression is a reliable method for diagnosing and monitoring therapy of dermatopathies caused by mites and can be used to replace the traditional deep skin scraping method. In addition, since it is less traumatic for the dog, this method shows more acceptance by the owner.

  13. HTS Nested magnet wound with 12 mm GdBCO tape and 4.4 mm YBCO tape

    International Nuclear Information System (INIS)

    Kang, Myung Hun; Ku, Myung Hwan; Cha, Guee Soo; Lim, Hyoung Woo

    2015-01-01

    The properties of High Temperature Superconducting (HTS) tapes are progressing, as HTS tapes evolve from 1st generation to 2nd generation. This paper presents design and construction of a 2nd generation HTS magnet consisting of two nested GdBCO and YBCO pancake coils. Two HTS tapes of different widths were used to wind the HTS nested magnet. Considering that a higher magnetic field is applied to the inner magnet than to the outer magnet, 12 mm GdBCO tape was used for winding the inner magnet, which consisted of four single pancake windings. Eight double pancake windings wound with 4.4 mm YBCO tapes were used for the outer magnet. The test results show that the central magnetic field of the HTS nested magnet was 920 mT. The measured critical currents of the inner and outer magnet at 77K were 80.8 A and 32.6 A, respectively

  14. The ENDF/B-VI photon interaction library

    International Nuclear Information System (INIS)

    Cullen, D.E.; Perkins, S.T.; Plechaty, E.F.

    1992-02-01

    The ENDF/B-VI photon interaction library includes data to describe the interaction of photons with the elements Z = 1 to 100 over the energy range 10 eV to 100 MeV. This library has been designed to meet the traditional needs of users to model the interaction and transport of primary photons. However, this library contains additional information which used in a combination with our other data libraries can be used to perform much more detailed calculations, e.g., emission of secondary fluorescence photons. This paper describes both traditional and more detailed uses of this library

  15. Tape casting fluorinated YBC123

    International Nuclear Information System (INIS)

    Taylor, J.A.T.; Luke, D.M.; Whiteley, B.A.

    1991-01-01

    Tape casting the superconducting Ba-Y-Cu oxide was accomplished by several laboratories and show promise for being a versatile forming technique. The major problem is low current density, probably due to lack of grain alignment and grain boundary related weak links. The latter problem may be due to formation of carbonates and hydroxides during binder burnout. Preliminary work done at Alfred shows that a bimodal powder size distribution displays significant alignment after tape casting and that F treated powder is resistant to attack by steam at 100C. Such corrosion resistant powder cast as form tape should survive the binder burnout without the detrimental grain boundary phases that develop from reaction of the superconducting phase, steam and carbon dioxide. This paper presents the results of an investigation of tape casting fluorinated powder with a bimodal size distribution

  16. Safety brake for tape reels

    Science.gov (United States)

    Carle, C. E.

    1977-01-01

    All-mechanical device senses end of tape and stops reel, even in event of electronic system failure. Assembly includes stop to prevent brake from overriding tape. Recentering mechanism returns brake to neutral position after torque is removed from reels.

  17. LTFR-4, Library Generated for Fast Reactor Design Program from JAERI Fast-Set Multigroup Constant

    International Nuclear Information System (INIS)

    Suzuki, Tomoo

    1971-01-01

    Nature of physical problem solved: The program processes JAERI-Fast group constants sets of less than 30-group and prepares a binary library tape for efficient usage by a series of related fast reactor design calculation programmes

  18. Biopiracy and the ethics of medical heritage: the case of India's traditional knowledge digital library'.

    Science.gov (United States)

    Kidd, Ian James

    2012-09-01

    Medical humanities have a central role to play in combating biopiracy. Medical humanities scholars can articulate and communicate the complex structures of meaning and significance which human beings have invested in their ways of conceiving health and sickness. Such awareness of the moral significance of medical heritage is necessary to ongoing legal, political, and ethical debates regarding the status and protection of medical heritage. I use the Indian Traditional Knowledge Digital Library as a case study of the role of medical humanities in challenging biopiracy by deepening our sense of the moral value of medical heritage.

  19. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    OpenAIRE

    Biju Chetri, U.T. Ifthikar Ali, Madhusmita Koch, Abhijit Dutta

    2016-01-01

    Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected...

  20. Strategy for robot motion and path planning in robot taping

    Science.gov (United States)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  1. Centrally managed tapes at DESY

    International Nuclear Information System (INIS)

    Hell, O.

    1994-01-01

    Tapes at DESY are managed by the computer center and thus offer virtually unlimited storage space to the DESY computer center users. This paper describes the most recent version of the DESY tape management system, its predecessors having been in service for many years

  2. Cache management of tape files in mass storage system

    International Nuclear Information System (INIS)

    Cheng Yaodong; Ma Nan; Yu Chuansong; Chen Gang

    2006-01-01

    This paper proposes the group-cooperative caching policy according to the characteristics of tapes and requirements of high energy physics domain. This policy integrates the advantages of traditional local caching and cooperative caching on basis of cache model. It divides cache into independent groups; the same group of cache is made of cooperating disks on network. This paper also analyzes the directory management, update algorithm and cache consistency of the policy. The experiment shows the policy can meet the requirements of data processing and mass storage in high energy physics domain very well. (authors)

  3. Tape-cast sensors and method of making

    Science.gov (United States)

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  4. Lifelong learning in public libraries principles, programs, and people

    CERN Document Server

    Gilton, Donna L

    2012-01-01

    Lifelong Learning in Public Libraries demonstrates that public librarians can promote learning by combining the elements of Information Literacy Instruction (ILI) with traditional practices of public libraries. This approach contributes to the information enfranchisement of patrons and enhances the fulfillment of the traditional goals and purposes of libraries. Donna L. Gilton provides background on ILI and current developments in public library instruction and also examines educational the

  5. Levitation characteristics of HTS tape stacks

    Energy Technology Data Exchange (ETDEWEB)

    Pokrovskiy, S. V.; Ermolaev, Y. S.; Rudnev, I. A. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2015-03-15

    Due to the considerable development of the technology of second generation high-temperature superconductors and a significant improvement in their mechanical and transport properties in the last few years it is possible to use HTS tapes in the magnetic levitation systems. The advantages of tapes on a metal substrate as compared with bulk YBCO material primarily in the strength, and the possibility of optimizing the convenience of manufacturing elements of levitation systems. In the present report presents the results of the magnetic levitation force measurements between the stack of HTS tapes containing of tapes and NdFeB permanent magnet in the FC and ZFC regimes. It was found a non- linear dependence of the levitation force from the height of the array of stack in both modes: linear growth at small thickness gives way to flattening and constant at large number of tapes in the stack. Established that the levitation force of stacks comparable to that of bulk samples. The numerical calculations using finite element method showed that without the screening of the applied field the levitation force of the bulk superconductor and the layered superconductor stack with a critical current of tapes increased by the filling factor is exactly the same, and taking into account the screening force slightly different.

  6. CARP: a computer code and albedo data library for use by BREESE, the MORSE albedo package

    International Nuclear Information System (INIS)

    Emmett, M.B.; Rhoades, W.A.

    1978-10-01

    The CARP computer code was written to allow processing of DOT angular flux tapes to produce albedo data for use in the MORSE computer code. An albedo data library was produced containing several materials. 3 tables

  7. ENDL-84. The Evaluated Nuclear Data Library of the Lawrence Livermore National Laboratory in the ENDF-5 format

    International Nuclear Information System (INIS)

    Cullen, D.E.; McLaughlin, P.K.; Lemmel, H.D.

    1990-09-01

    This document summarizes the contents of the evaluated nuclear data library (ENDL) by the Lawrence Livermore National Laboratory, USA, converted to ENDF-5 format. The library contains evaluated data for all significant neutron reactions in the energy range from 10 -4 eV to 20 MeV for 94 elements or isotopes. The entire library or selective retrievals from it can be obtained on magnetic tape, free of charge, from the IAEA Nuclear Data Section. (author)

  8. Preparation and characterization of Bi-2223 tapes

    International Nuclear Information System (INIS)

    Hense, K.; Kirchmayr, H.; Kovac, P.; Lackner, R.; Mueller, M.; Pachla, W.; Pitel, J.; Polak, M.; Usak, P.

    2003-01-01

    In a concerted action between Austrian, Slovakian and Polish research institutes Bi-2223 tapes have been prepared and characterized by different physical methods. Metallographic studies by optical as well as electron microscopy, measurements of critical current (angle dependent) and losses have been performed. Properties of individual filaments extracted from multifilamentary tapes were also studied. Uniformity of local I C of these filaments were considerably lower than that of the whole tape. This indicates that improvement of filament homogeneity could improve the over all J C in tapes. The application of these tapes for optimized magnet coils will also be discussed. From these investigations a better understanding of the mechanisms, limiting the critical current could be achieved and more optimized preparation methods can be envisioned

  9. Reel-to-reel substrate tape polishing system

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  10. Ubiquitous Graphene Electronics on Scotch Tape

    Science.gov (United States)

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-07-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm-2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V-1 s-1 the transistors still showed high mobility of 1254 (±478) cm2 V-1 s-1 even after they were crumpled.

  11. FENDL/A-2.0. Neutron activation cross section data library for fusion applications

    International Nuclear Information System (INIS)

    Pashchenko, A.B.; Wienke, H.; Kopecky, J.; Sublet, J.C. Sublet; Forrest, R.A.

    1997-01-01

    This document describes the contents of a comprehensive neutron cross section data library for 13,006 neutron activation reactions with 739 target nuclides from H (A=1,Z=1) to Cm (A=248,Z=96), in the incident energy range up to 20 MeV. FENDL/A-2 is a sublibrary of FENDL-2, the second revision of the evaluated nuclear data library for fusion applications. It is supplemented by a decay data library FENDL/D-2 in ENDF-6 format for 1867 nuclides. The data are available from the IAEA Nuclear Data Section online via INTERNET by FTP command, or on magnetic tape upon request. (author)

  12. BALLISTIC RESISTANT ARTICLES COMPRISING TAPES

    NARCIS (Netherlands)

    VAN DER EEM, JORIS; HARINGS, JULES; JANSE, GERARDUS; TJADEN, HENDRIK

    2015-01-01

    The invention pertains to a ballistic-resistant moulded article comprising a compressed stack of sheets comprising reinforcing tapes having a tensile strength of at least 1.0 GPa, a tensile modulus of at least 40 GPa, and a tensile energy-to-break of at least 15 J/g, the direction of the tapes

  13. Design of double tape recorder data acquisition system

    International Nuclear Information System (INIS)

    Guo Tianrui; Du Yifei

    1995-01-01

    In the data acquisition system supported by the microcomputer tape recorder, as the acquisition speed is often limited by the low speed of tape recorder, so a double tape recorder system is designed. In this system, two tape recorders are used in on-line acquisition system simultaneously. One DMA channel used is one designed for soft disk driver, another DMA channel used is one retained for user. By this way, the speed of tape writing could be increased to nearly twice as much. In order to prevent the data confusion, the authors open two data buffers in system and write different mark in each buffer, then write the data block to two tape recorders according to the mark. The system complies with the principle: 'Double write, Double read'

  14. Diagnostics of sources of disturbances and distribution of vibrations over the width of a tape in tape-feed mechanisms

    Science.gov (United States)

    Kenstavichyus, A. B. B.

    1973-01-01

    Disturbances created by certain assemblies and components of tape-feed mechanisms (TFM) and acting on a moving magnetic tape are studied. The method, based on elements of digital logic, is established by stress-strain diagrams of the longitudinal deformations and vibrations across the width of a magnetic tape. Experimental studies were carried out for determination of the functional relationships of longitudinal deformations in a section of magnetic tape to the magnitude of roller play, tension vibrations rate of movement, and elasticity of magnetic tapes. A block diagram of the measurements is shown. Appropriate digital computer algorithms and programs were proposed for statistical analysis of the data obtained. Estimates of the mathematical expectation, dispersion, intercorrelation function, energy spectral density, and distribution pattern of the random process values were calculated.

  15. ENDF/B-5 Fission Products Library. Rev. 2

    International Nuclear Information System (INIS)

    Schwerer, O.; Pronyaev, V.G.; Lemmel, H.D.

    1984-07-01

    This document summarizes contents and documentation of the 1984 version of the Fission Products Nuclear Data File of the ENDF/B-5 Library (Rev. 2) maintained by the National Nuclear Data Center (NNDC) at the Brookhaven National Laboratory, USA. This file contains numerical neutron reaction data and decay data for 877 fission product nuclides. The entire file or selective retrievals from it can be obtained on magnetic tape from the IAEA Nuclear Data Section. (author)

  16. Urinary incontinence - tension-free vaginal tape

    Science.gov (United States)

    ... ency/article/007377.htm Urinary incontinence - tension-free vaginal tape To use the sharing features on this page, please enable JavaScript. Placement of tension-free vaginal tape is surgery to help control stress urinary ...

  17. Index of nuclear data libraries available from the IAEA nuclear data section

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1996-11-01

    This document lists more than 100 nuclear data libraries together with references that give more detailed information about these libraries. The data libraries include neutron cross-sections, resonance parameters, fission-product yields, nuclear structure and decay data, gamma-rays from radionuclides, data of nuclear reactions induced by charged particles or heavy ions, photonuclear data, photoatomic interaction data, and many others, partly with related data processing computer codes. All data and documentation references are available upon request from the IAEA Nuclear Data Section, free of charge on magnetic tape, PC diskettes, or online through www or INTERNET: either menu driven within the Nuclear Data Information System (NDIS), or through FTP file transfer. (author)

  18. Index of nuclear data libraries available from the IAEA Nuclear Data Section

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1996-01-01

    This document lists more than 100 nuclear data libraries together with references that give more detailed information about these libraries. The data libraries include neutron cross-sections, resonance parameters, fission-product yields, nuclear structure and decay data, gamma-rays from radionuclides, data of nuclear reactions induced by charged particles or heavy ions, photonuclear data, photoatomic interaction data, and many others, partly with related data processing computer codes. All data documentation references are available upon request from the IAEA Nuclear Data Section, free of charge on magnetic tape, PC diskettes, or online through the INTERNET computer network: either menu driven within the Nuclear Data Information System (NDIS), or through FTP file transfer. (author)

  19. Index of nuclear data libraries available from the IAEA Nuclear Data Section

    International Nuclear Information System (INIS)

    Lemmel, H.D.; Schwerer, O.

    1997-01-01

    This document lists more than 100 nuclear data libraries together with references that give more detailed information about these libraries. The data libraries include neutron cross-sections, resonance parameters, fission-product yields, nuclear structure and decay data, gamma-rays from radionuclides, data of nuclear reactions induced by charged particles or heavy ions, photonuclear data, photoatomic interaction data, and many others, partly with related data processing computer codes. All data and documentation references are available upon request from the IAEA Nuclear Data Section, free of charge on magnetic tape, PC diskettes, CD-ROM or online through WWW, Telnet (menu driven within the Nuclear Data Information System NDIS), or through FTP file transfer. (author)

  20. Index of nuclear data libraries available from the IAEA Nuclear Data Section

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1994-01-01

    This document lists more than 100 nuclear data libraries together with references that give more detailed information about these libraries. The data libraries include neutron cross-sections, resonance parameters, fission-product yields, nuclear structure and decay data, gamma-rays from radionuclides, data of nuclear reactions induced by charged particles or heavy ions, photonuclear data, photoatomic interaction data, and many others, partly with related data processing computer codes. All data and documentation references are available upon request from the IAEA Nuclear Data Section, free of charge on magnetic tape, PC diskettes, or online through the INTERNET computer network: either menu driven within the Nuclear Data Information System (NDIS), or through FTP file transfer. (author)

  1. JEF-2. The evaluated Nuclear Data Library of the NEA Data Bank

    International Nuclear Information System (INIS)

    Lemmel, H.D.; Schwerer, O.

    1993-01-01

    This document summarizes the contents of JEF-2, the Joint Evaluated File of nuclear data compiled by the OECD Nuclear Energy Agency Data Bank, finalized in 1992 and released in 1993. The entire library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section free of charge. (author)

  2. JEF-1: The Evaluated Nuclear Data Library of the NEA Data Bank

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1991-04-01

    This document summarizes the contents of JEF-1, the Joint Evaluated File of nuclear data compiled by the OECD Nuclear Energy Agency Data Bank, finalized in 1986 and released in 1990. The entire library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section free of charge. (author)

  3. JEF-1. The evaluated nuclear data library of the NEA Data Bank

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1990-09-01

    This document summarizes the contents of JEF-1, the Joint Evaluated File of nuclear data compiled by the OECD Nuclear Energy Agency Data Bank, finalized in 1986 and released in 1990. The entire library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section free of charge. (author)

  4. Effect of binder concentration and blade gap on Yttria stabilized Zirconia tapes obtained by tape casting

    Energy Technology Data Exchange (ETDEWEB)

    Mena Garcia, J.; Reyes Rojas, A.; Rodriguez Gonzalez, C.A.; Hernandez Paz, J.; Garcia Casillas, P.E.; Enriquez Carrejo, J.L.; Camacho Montes, H.

    2016-07-01

    The tape casting method has kept its interest over the years due to the wide spectrum of its applications and its economic viability in comparison to other techniques focused on micrometric thin films. Two key parameters for tape casting are the binder relative amount and the Dr. Blade gap. The binder relative amount has a strong influence on the rheological properties for the ceramic YSZ slurry (ethanol, butanone, TEA, PVB, PEG, DEP). The coefficient K and the exponent m of the Cross model are reported to be inside the ranges 152.25-231.12 and 0.00987-0.26646 for PVB binder weight percentage concentrations between 6% and 12%. It is possible to describe the ceramic tape thickness dependence by means of a linear relation depending on the Dr. Blade gap whose linear coefficients (slope) are equal to 0.0350 and 0.2171 for green and sintered tapes respectively, with the YSZ slurry of the present work. (Author)

  5. Methods and systems for fabricating high quality superconducting tapes

    Science.gov (United States)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  6. Increasing the efficiency of tape-based storage backends

    International Nuclear Information System (INIS)

    Bessone, Nicola; Cancio, German; Murray, Steve; Taurelli, Giulia

    2010-01-01

    HSM systems such as the CERN's Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for increasing the performance of repacking data from old to newer generation tape media with substantially reduced hardware costs. In this paper, we will describe the improvements for migration policies and priorities, as well as the proposed tape format and the changes which will be applied to the architecture of the CASTOR mass storage system.

  7. BROND-2.2. Russian evaluated neutron reaction data library. Summary documentation

    Energy Technology Data Exchange (ETDEWEB)

    Lemmel, H D; McLaughlin, P K

    1994-01-01

    BROND-2, the computerized data library for evaluated neutron reaction data of the Russian Federation was released in 1992 and updated in 1993 as BROND-2.2. Its content is summarized in this document. Upon request it is available on magnetic tape, costfree, from the IAEA Nuclear Data Section. It is also available within the IAEA online system NDIS. (author)

  8. Home Economics Archive: Research, Tradition and History (HEARTH)

    Science.gov (United States)

    Click here to go to the Mann Library Home Page Click here to return to the HEARTH Home Page Click , Tradition and History HEARTH is a core electronic collection of books and journals in Home Economics and Archive: Research, Tradition and History (HEARTH). Ithaca, NY: Albert R. Mann Library, Cornell University

  9. Methods and systems for fabricating high quality superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  10. Increasing the efficiency of tape-based storage backends

    CERN Document Server

    Bessone, N; Murray, S; Taurelli, G; CERN. Geneva. IT Department

    2010-01-01

    HSM systems such as the CERN’s Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for incre...

  11. Fool's gold why the internet is no substitute for a library

    CERN Document Server

    Herring, Mark Y

    2007-01-01

    ""Valuable""--Against the Grain; ""rcommended""--Association of Jewish Libraries Newsletter; ""thorough""--Technicalities; ""makes a case for the continued need for traditional libraries""--www.heraldonline.com. This work skeptically explores the notion that the internet will soon obviate any need for traditional print-based academic libraries, and makes a case for the library's staying power in the face of technological advancements.

  12. The use of library learning centres in the Ghana Public Library: A ...

    African Journals Online (AJOL)

    One of the current trends in public library service provision is the introduction of Learning Centres in addition to the traditional services provided. It is in the light of this that this study sets out to find out how feasible it is to establish learning centres in public libraries in Ghana and their possible influences on user patronage.

  13. [The future of scientific libraries].

    Science.gov (United States)

    De Fiore, Luca

    2013-10-01

    "Making predictions is always very difficult, especially about the future". Niels Bohr's quote is very appropriate when looking into the future of libraries. If the Web is now the richest library in the world, it is also the most friendly and therefore the most convenient. The evolution of libraries in the coming years - both traditional and online - will probably depend on their ability to meet the information needs of users: improved ease of use and better reliability of the information. These are objectives that require money and - given the general reduction in budgets - it is not obvious that the results will be achieved. However, there are many promising experiences at the international level that show that the world of libraries is populated by projects and creativity. Traditional or digital, libraries will increasingly present themselves more as a sharing tool than as a repository of information: it is the sharing that translates data into knowledge. In the healthcare field, the integration of online libraries with the epidemiological information systems could favor the fulfillment of unconscious information needs of health personnel; libraries will therefore be a key tool for an integrated answer to the challenge of continuing education in medicine. The Internet is no longer a library but an information ecosystem where the data are transformed into knowledge by sharing and discussion.

  14. Melt processing of Yb-123 tapes

    International Nuclear Information System (INIS)

    Athur, S. P.; Balachandran, U.; Salama, K.

    2000-01-01

    The innovation of a simple, scalable process for manufacturing long-length conductors of HTS is essential to potential commercial applications such as power cables, magnets, and transformers. In this paper the authors demonstrate that melt processing of Yb-123 tapes made by the PIT route is an alternative to the coated conductor and Bi-2223 PIT tape fabrication techniques. Ag-clad Yb-123 tapes were fabricated by groove rolling and subsequently, melt processed in different oxygen partial pressures in a zone-melting furnace with a gradient of 140 C/cm. The transition temperatures measured were found to be around 81 K undermost processing conditions. EPMA of the tapes processed under different conditions show the 123 phase to be Ba deficient and Cu and Yb rich. Critical current was measured at various temperatures from 77 K to 4.2 K. The J c increased with decrease in pO 2 . The highest I c obtained was 52 A at 4.2 K

  15. Music Provision in UK Public Libraries

    Science.gov (United States)

    Dorney, Carl; McKnight, Cliff

    2004-01-01

    Public library music provision, as a less traditional role for public libraries, has always caused contention: a vital source of cultural materials within the community though never confirmed to be a core part of library services by the Government. This article concerns itself with a detailed consideration of the decline of music services over the…

  16. Transmission electron microscopy investigation of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Andersen, L.G.; Bals, S.; Tendeloo, G. Van

    2001-01-01

    during the tape processing, (3) a study of the grain boundaries on an atomic scale, including intergrowth investigations. Tapes with different process parameters have been compared with respect to the microstructure. A fully processed tape has on the average 50% thicker Bi-2223 grains than a tape after......The microstructure of (Bi,Pb)(2)Sr2Ca2CuOx (Bi-2223) tapes has been investigated by means of transmission electron microscopy (TEM) and high-resolution TEM. The emphasis has been placed on: (1) an examination of the grain morphology and size, (2) grain and colony boundary angles, which are formed...

  17. The National electronic library a guide to the future for library managers

    CERN Document Server

    1996-01-01

    The National Information Infrastructure will bring information to the doorstep of every household. Librarianship must respond to this development through the National Electronic Library. Librarianship as a profession must set the information agenda if it is to be a viable and influential entity in the electronic environment. Traditional library services are being redefined by technology, and the concept of the National Electronic Library must combine the roles of the academic institution, public enterprise, and library education. This professional reference is a guide to assist librarians in planning for the future.||The volume maintains that the growing electronic environment is driving a cultural transformation in which libraries must examine and understand what libraries have been, what they are, and what they need to be. Libraries need to participate actively in this transformation in order to remain the central providers of information and related services. The book explores the National Electronic Libra...

  18. Perceived Organizational Red Tape and Organizational Performance in Public Services

    DEFF Research Database (Denmark)

    Jacobsen, Christian Bøtcher; Jakobsen, Mads Leth

    2018-01-01

    The claim that perceived organizational red tape hampers public services has become a central theme in public administration research. Surprisingly, however, few scholars have empirically examined the impact of perceived red tape on organizational performance. This study empirically analyzes how...... perceived organizational red tape among managers and frontline staff relates to objectively measured performance. The data consists of survey responses from teachers and principals at Danish upper secondary schools combined with grade-level administrative performance data. Based on theories of red tape...... and motivation crowding, we hypothesize that perceived organizational red tape reduces performance within such organizations. The empirical result is a small, negative relationship between staff perception of red tape and performance, and no relationship between manager-perceived red tape and performance....

  19. Melt formed superconducting joint between superconducting tapes

    International Nuclear Information System (INIS)

    Benz, M.G.; Knudsen, B.A.; Rumaner, L.E.; Zaabala, R.J.

    1992-01-01

    This patent describes a superconducting joint between contiguous superconducting tapes having an inner laminate comprised of a parent-metal layer selected from the group niobium, tantalum, technetium, and vanadium, a superconductive intermetallic compound layer on the parent-metal layer, a reactive-metal layer that is capable of combining with the parent-metal and forming the superconductive intermetallic compound, the joint comprising: a continuous precipitate of the superconductive intermetallic compound fused to the tapes forming a continuous superconducting path between the tapes

  20. Comparison of Cloud vs. Tape Backup Performance and Costs with Oracle Database

    OpenAIRE

    Zrnec, Aljaž; Lavbič, Dejan

    2011-01-01

    Current practice of backing up data is based on using backup tapes and remote locations for storing data. Nowadays, with the advent of cloud computing a new concept of database backup emerges. The paper presents the possibility of making backup copies of data in the cloud. We are mainly focused on performance and economic issues of making backups in the cloud in comparison to traditional backups. We tested the performance and overall costs of making backup copies of data in Ora...

  1. Multiple Generations on Video Tape Recorders.

    Science.gov (United States)

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  2. Bidirectional recording performance of a perpendicular evaporated Co-CoO tape

    Energy Technology Data Exchange (ETDEWEB)

    Motohashi, K. [Sony Corporation, 3-4-1 Sakuragi, Tagajo-shi, Miyagi 985-0842 (Japan)], E-mail: Kazunari.Motohashi@jp.sony.com; Ikeda, N.; Sato, T.; Shiga, D.; Ono, H.; Onodera, S. [Sony Corporation, 3-4-1 Sakuragi, Tagajo-shi, Miyagi 985-0842 (Japan)

    2008-11-15

    It is the first report on the recording performance of a perpendicular metal evaporated (ME) tape measured with a giant magnetoresistive head. To solve the application difficulty of oblique evaporated tape media to linear scan tape systems, a perpendicular evaporated Co-CoO tape was proposed instead. The prepared sample showed perpendicular anisotropy with coercivity of 107.3 kA/m, M{sub r}t of 3.9 mA and squareness of 0.25. Identical recording characteristics were obtained for both head-media moving directions, which enables the application of perpendicular evaporated Co-CoO tape to linear scan tape systems. The better carrier-to-noise ratio was also confirmed by comparison with a current advanced product of metal particulate tape, which can realize the higher recording density of linear scan tape systems using ME tape.

  3. Bidirectional recording performance of a perpendicular evaporated Co-CoO tape

    International Nuclear Information System (INIS)

    Motohashi, K.; Ikeda, N.; Sato, T.; Shiga, D.; Ono, H.; Onodera, S.

    2008-01-01

    It is the first report on the recording performance of a perpendicular metal evaporated (ME) tape measured with a giant magnetoresistive head. To solve the application difficulty of oblique evaporated tape media to linear scan tape systems, a perpendicular evaporated Co-CoO tape was proposed instead. The prepared sample showed perpendicular anisotropy with coercivity of 107.3 kA/m, M r t of 3.9 mA and squareness of 0.25. Identical recording characteristics were obtained for both head-media moving directions, which enables the application of perpendicular evaporated Co-CoO tape to linear scan tape systems. The better carrier-to-noise ratio was also confirmed by comparison with a current advanced product of metal particulate tape, which can realize the higher recording density of linear scan tape systems using ME tape

  4. Open Shelves/Closed Shelves in Research Libraries

    Science.gov (United States)

    Rovelstad, Mathilde V.

    1976-01-01

    Traces the traditional method of making books accessible through their topical arrangement on library shelves, outlines the reasons for the abandonment of this method in European research libraries, explores its modified reappearance in postwar academic libraries, and cites modern arguments against the practice of making an entire research…

  5. Mechanism Design and Testing of a Self-Deploying Structure Using Flexible Composite Tape Springs

    Science.gov (United States)

    Footdale, Joseph N.; Murphey, Thomas W.

    2014-01-01

    The detailed mechanical design of a novel deployable support structure that positions and tensions a membrane optic for space imagining applications is presented. This is a complex three-dimensional deployment using freely deploying rollable composite tape spring booms that become load bearing structural members at full deployment. The deployment tests successfully demonstrate a new architecture based on rolled and freely deployed composite tape spring members that achieve simultaneous deployment without mechanical synchronization. Proper design of the flexible component mounting interface and constraint systems, which were critical in achieving a functioning unit, are described. These flexible composite components have much potential for advancing the state of the art in deployable structures, but have yet to be widely adopted. This paper demonstrates the feasibility and advantages of implementing flexible composite components, including the design details on how to integrate with required traditional mechanisms.

  6. Digital Libraries and Digitisation: An Overview and Critique

    Science.gov (United States)

    Rikowski, Ruth

    2008-01-01

    This article provides an overview of some of the main areas surrounding the broad topic of "Digital Libraries". This includes the advantages and costs of digitisation; the traditional and digital library; the library community and digitisation; and an examination of various digital library projects. It is not exhaustive, but hopefully, it provides…

  7. Library orientation on videotape: production planning and administrative support.

    Science.gov (United States)

    Shedlock, J; Tawyea, E W

    1989-01-01

    New student-faculty-staff orientation is an important public service in a medical library and demands creativity, imagination, teaching skill, coordination, and cooperation on the part of public services staff. The Northwestern University Medical Library (NUML) implemented a video production service in the spring of 1986 and used the new service to produce an orientation videotape for incoming students, new faculty, and medical center staff. Planning is an important function in video production, and the various phases of outlining topics, drafting scripts, matching video sequences, and actual taping of video, voice, and music are described. The NUML orientation videotape demonstrates how reference and audiovisual services merge talent and skills to benefit the library user. Videotape production, however, cannot happen in a vacuum of good intentions and high ideals. This paper also presents the management support and cost analysis needed to make video production services a reality for use by public service departments.

  8. Preparing superconducting nanopowder based YBCO/Ag tapes

    DEFF Research Database (Denmark)

    Paturi, P.; Raittila, J.; Grivel, J.C.

    2002-01-01

    YBCO nanopowder consisting of 1-3 nm thick and 40 nm wide particles has been used to make silver clad superconducting tapes. After annealing in nitrogen at 945 degreesC for 10 h a critical current of 5.02 A (3300 A/cm(2)) was attained, Annealing in mixed atmosphere of oxygen and nitrogen was also...... carried out and this procedure produced tapes with a critical current of 2.83 A (2200 A/cm(2)). These tapes show very good characteristics in magnetic fields. (C) 2002 Elsevier Science B.V. All rights reserved....

  9. 'EN6-PHOTO' and 'JEF-2/PHOTO'. Photo-Atomic Interaction Data Library by the Lawrence Livermore National Laboratory, USA. Summary documentation

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1994-01-01

    The Photo-Atomic Interaction Data Library of the Livermore Evaluated Photon Data Library (EPDL) contains pair production cross-sections, photoelectric cross-sections, atomic form factors, coherent scattering cross-sections and some other data for all the elements from Z = 1 to 100. There are two versions of this library, the one being part of the U.S. ENDF/B-6 system, the other being part of the European JEF-2 system. Both are available on magnetic tape costfree from the IAEA Nuclear Data Section. (author)

  10. Fabrication of Polyimide-Matrix/Carbon and Boron-Fiber Tape

    Science.gov (United States)

    Belvin, Harry L.; Cano, Roberto J.; Treasure, Monte; Shahood, Thomas W.

    2007-01-01

    The term HYCARB denotes a hybrid composite of polyimide matrices reinforced with carbon and boron fibers. HYCARB and an improved process for fabricating dry HYCARB tapes have been invented in a continuing effort to develop lightweight, strong composite materials for aerospace vehicles. Like other composite tapes in this line of development, HYCARB tapes are intended to be used to build up laminated structures having possibly complex shapes by means of automated tow placement (ATP) - a process in which a computer-controlled multiaxis machine lays down prepreg tape or tows. The special significance of the present process for making dry HYCARB for ATP is that it contributes to the reduction of the overall cost of manufacturing boron-reinforced composite-material structures while making it possible to realize increased compression strengths. The present process for making HYCARB tapes incorporates a "wet to dry" process developed previously at Langley Research Center. In the "wet to dry" process, a flattened bundle of carbon fiber tows, pulled along a continuous production line between pairs of rollers, is impregnated with a solution of a poly(amide acid) in N-methyl-2-pyrrolidinone (NMP), then most of the NMP is removed by evaporation in hot air. In the present case, the polyamide acid is, more specifically, that of LaRC. IAX (or equivalent) thermoplastic polyimide, and the fibers are, more specifically, Manganite IM7 (or equivalent) polyacrylonitrile- based carbon filaments that have a diameter of 5.2 m and are supplied in 12,000-filament tows. The present process stands in contrast to a prior process in which HYCARB tape was made by pressing boron fibers into the face of a wet carbon-fiber/ poly(amide acid) prepreg tape . that is, a prepreg tape from which the NMP solvent had not been removed. In the present process, one or more layer(s) of side-by-side boron fibers are pressed between dry prepreg tapes that have been prepared by the aforementioned gwet to dry h

  11. Experimental Tape Casting of Adjacently Graded Materials for Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Bulatova, Regina

    encompass modification of the entire tape caster into a multi chamber unit, establishment of the optimal operating parameters such as casting gap, speed, and slurry level in the tape caster reservoir, and elucidation of the impact of chamber partition design on the quality of the final tape. The second...... of the side-by-side tape casting technique: recognising critical parameters which affect the quality of a graded tape, shape and position of the interface area. Studied parameters can be divided into two categories: operational parameters and slurry formulation optimisation. The operational parameters...

  12. Getting Back to Basics: A Student Library Orientation Tour

    Science.gov (United States)

    Sciammarella, Susan; Fernandes, Maria Isabel

    2007-01-01

    In developing a Library Orientation Tour, it is important to be perceptive about the needs of a college population. At Queensborough Community College the student population is a mix of traditional and non-traditional students from diversified backgrounds. The initial contact with the Library, and its resources, may be overwhelming for students…

  13. Tamper tape seals

    International Nuclear Information System (INIS)

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R ampersand D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique open-quotes fingerprintclose quotes characteristics that can be accessed as desired

  14. Discussion on construction of scientific and technological digital library in nuclear industry

    International Nuclear Information System (INIS)

    Yin Huilan

    2010-01-01

    With the rapid development of digital and network technology, traditional libraries have been unable to meet the needs of the times. Digital libraries will gradually take the place of traditional libraries. Under the circumstances, how will the libraries of the enterprises in nuclear industry face this transformation? This paper gives the brief descriptions and comparative analyses in the four aspects: the definition of the digital library, the meaning of nuclear scientific and technological digital library, the characteristics of the digital library, and major problems in the construction of nuclear scientific and technological digital library that should be solved. Therefore, setting up the digital library is very important. At the same time, it's very necessary and urgent for the libraries of the enterprises in nuclear industry to establish nuclear scientific and technological digital library. (author)

  15. Measuring Effectiveness in a Virtual Library

    Science.gov (United States)

    Finch, Jannette L.

    2010-01-01

    Measuring quality of service in academic libraries traditionally includes quantifiable data such as collection size, staff counts, circulation numbers, reference service statistics, qualitative analyses of customer satisfaction, shelving accuracy, and building comfort. In the libraries of the third millennium, virtual worlds, Web content and…

  16. Celebrating Co-operation among Saskatchewan’s Libraries: The Multitype Library Board, 1996-2016

    Directory of Open Access Journals (Sweden)

    Michael Shires

    2016-03-01

    Full Text Available Saskatchewan’s Multitype Library Board (MLB celebrates its 20th anniversary in 2016. It was established under the passage of the provincial government’s The Libraries Co- operation Act in 1996 to facilitate the co-operative development of the multitype library system in Saskatchewan. This legislation is unique in Canada. The MLB is a Minister of Education Advisory Board and it provides a forum to promote and facilitate co-operation among over 320 public libraries in 10 provincial systems, 25 post-secondary libraries, 755 school libraries, several special libraries, and other information providers. Major milestones of the MLB include helping to eliminate the Provincial Sales Tax on library subscriptions, establishing a provincial digitization plan, and creating a cross-sector database licensing program that has resulted in a projected value of 14.8 million dollars to Saskatchewan users in 2014. The development of the MLB and the impact of the programs it has initiated will be discussed, and recommendations for developing a collaborative initiative will be provided. Le Multitype Library Board (MLB de Saskatchewan fête son 20e anniversaire en 2016. Il était établi sous l’Acte The Libraries Co-operation du parti Libéral en 1996 pour faciliter le développement coopératif du système de bibliothèque Multitype en Saskatchewan. Cette législation est unique au Canada. Le MLB est un comité consultatif du ministère de l’Éducation et il fournit un forum pour promouvoir et faciliter la coopération entre plus de 320 bibliothèques publiques dans dix systèmes provinciaux, 25 bibliothèques postsecondaires, 755 bibliothèques scolaires, plusieurs bibliothèques spéciales, et d’autres fournisseurs d’informations. Les étapes importantes du MLB comprennent, à aider à éliminer les taxes de vente provinciale sur les abonnements aux bibliothèques, à établir un plan provincial de numérisation, et à créer un programme de licence

  17. Kinesio Taping Fundamentals for the Equine Athlete.

    Science.gov (United States)

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Three-dimensional modelling of metal evaporated tape

    International Nuclear Information System (INIS)

    Kay, G.E.

    1999-06-01

    As developments in magnetic recording increase, the demands for high density recording media continue to rise. One particular medium developed towards meeting these needs is the commercially successful metal evaporated (ME) tape. To provide a deeper understanding of the magnetic processes occurring in recording media, theoretical studies are carried out to complement experimental observations. Therefore, this thesis is concerned with developing a micromagnetic model to simulate the magnetic behaviour of ME tape. ME tape consists of bundles of granular columns which are tilted towards the film normal. The morphology of the film influences the magnetic behaviour and a 3D model is developed in this thesis to represent the columnar structure and the granular nature of ME tape. A Monte Carlo algorithm, consisting of a 'move and grow' procedure, is developed to generate an irregular system of spherical grains whose radii were generated from a log-normal distribution. This structure provides the foundation for modelling columns of ME tape. Initially an isolated column of ME tape was investigated. Grains were considered to be single domain and the dynamic process of the magnetic moments was explored by the Landau-Lifschitz equation. The model demonstrated that as the strength of the exchange coupling parameter increased, then moments which were strongly coupled resisted large negative fields and square hysteresis loops with a high coercivity were produced. Reversal of the moments was observed to be initiated at the ends of a column and then propagated throughout the column. This was attributed to large demagnetising fields and was particularly evident in the model with aligned easy axes. If the easy axes were randomly orientated then more disorder was present in the model and moments rotated incoherently. This produced hysteresis loops that were less square than those of the aligned model. The results also showed how the microstructure influenced the reversal processes

  19. Numerical and Experimental Investigation of the Electromechanical Behavior of REBCO Tapes

    Science.gov (United States)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2015-12-01

    To fully characterize the electromechanical behavior of a Twisted Stacked-Tape Cable (TSTC) it is important to understand the performance of the individual REBCO tapes under various loading conditions. Numerical modeling and experimentation have been used to investigate the electromechanical characteristics of two commercially available REBCO tapes (SuperPower and SuNAM). Tension and combined tension-torsion experiments on single tapes have been continued, from prior preliminary studies, to characterize their critical current behavior and mechanical strength. Additionally, structural finite element analysis was performed on single tapes under tension and combined tension-torsion to investigate the strain dependence of the critical current. The numerical results were compared to the experimental findings for validation. The SuNAM experimental data matched the numerical model very well while the SuperPower tape experienced degradation at lower stress and strain than predicted in the model. The Superpower tape also displayed greater variability in critical current between different samples as compared with the SuNAM tape.

  20. Effects of ultrasound therapy with taping PNF training and PNF training with taping in treatment and rehabilitation of sports injuries of high ankle sprain

    Directory of Open Access Journals (Sweden)

    D L Charly Daniel

    2017-01-01

    Conclusions: It was concluded that combining ultrasound with taping and PNF training with taping were found to be more beneficial in the treatment and rehabilitation of high ankle sprain injury. The combined effect of UT, PNF training, and taping may be explored by future researchers.

  1. AC power losses in Bi-2223/Ag HTS tapes

    International Nuclear Information System (INIS)

    Savvides, N.; Reilly, D.; Mueller, K.-H.; Herrmann, J.

    1998-01-01

    Full text: We report measurements at 77 K of the transport ac losses of Bi-2223/Ag composite tapes. The investigated tapes vary from single filament to multifilament construction and include both conventional tapes and other conductor shapes with twisted filaments. The self-field ac losses were determined at 77 K and 60 Hz as a function of ac current amplitude (0 - 100 A). We observe different behaviour among tapes depending on their quality and strain history. For 'good' virgin tapes the experimental data are well described by the Norris equations for the dependence of power loss P on the amplitude I m of the transport current. The data of good monofilament tapes are fitted to the Norris equation P ∼ I m n for an elliptical cross section (ie. n = 3) and the data of good multifilament tapes are fitted to the Norris equation for a rectangular strip (ie. n = 4). Many specimens, however, show a range of behaviour with lower values of n. Based on our work on the effect of strain on the dc transport properties of tapes, we carried out detailed investigations of the effect of controlled applied bend strain on the ac loss. Our results show that irreversible damage to superconducting filaments (ie. cracks) cause the ac loss to rise and n to decrease with increasing strain. In addition, applied strains much greater than the irreversible strain limit cause the ac loss to increase by several orders of magnitude and become ohmic in character with n = 2. Theoretical work is in progress to model the observed behaviour

  2. FENDL/D-1.0. Decay data library for fusion applications version 1 of January 1992. Summary documentation

    International Nuclear Information System (INIS)

    Pashchenko, A.B.

    1995-01-01

    This document describes the FENDL/D-1.0 decay data library which is the sublibrary of FENDL, the evaluated nuclear data library for fusion applications. The FENDL/D-1.0 was generated by merging data from ENDF/B-6 and from ENSDF (version of May 1990) and contains the basic information for approximately 2900 nuclides and isomers needed for general activation calculations. The data are available from the IAEA Nuclear Data Section online via INTERNET by FTP command, or on magnetic tape upon request. (author). 1 tab

  3. Using massive digital libraries a LITA guide

    CERN Document Server

    Weiss, Andrew

    2014-01-01

    Some have viewed the ascendance of the digital library as some kind of existential apocalypse, nothing less than the beginning of the end for the traditional library. But Weiss, recognizing the concept of the library as a ""big idea"" that has been implemented in many ways over thousands of years, is not so gloomy. In this thought-provoking and unabashedly optimistic book, he explores how massive digital libraries are already adapting to society's needs, and looks ahead to the massive digital libraries of tomorrow, coveringThe author's criteria for defining massive digital librariesA history o

  4. Data analysis of event tape and connection

    International Nuclear Information System (INIS)

    Gong Huili

    1995-01-01

    The data analysis on the VAX-11/780 computer is briefly described, the data is from the recorded event tape of JUHU data acquisition system on the PDP-11/44 computer. The connection of the recorded event tapes of the XSYS data acquisition system on VAX computer is also introduced

  5. Transobturator tapes are preferable over transvaginal tapes for the management of female stress urinary incontinence: Against

    Directory of Open Access Journals (Sweden)

    Arun Chawla

    2009-01-01

    Full Text Available Midurethral placement of tension-free vaginal tapes with a transvaginal route for stress urinary incontinence achieves higher and better long-term success rates than the transobturator route. Bladder perforations are reported more in transvaginal tape (TVT but incidences of vaginal erosions, extrusion, and groin pain are exceedingly more in TOT groups. There is no clear evidence that transobturator tape (TOT is associated with less post-operative voiding problems than TVT. Major complications such as bowel injuries and significant vascular injuries with TVT are rare. TVT has been found to be superior to TOT and preferable in technically demanding conditions such as prior anti-incontinence operation failures, obese women, and very elevated and scarred lateral cul-de sac. TVT is always preferred in severe grades of stress urinary incontinence and with patients of intrinsic sphincter deficiency (ISD with little or no urethral mobility.

  6. Carbon Nanotube-Based Synthetic Gecko Tapes

    Science.gov (United States)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  7. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    International Nuclear Information System (INIS)

    Takayasu, Makoto; Chiesa, Luisa

    2015-01-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour. (paper)

  8. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    Science.gov (United States)

    Takayasu, Makoto; Chiesa, Luisa

    2015-12-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour.

  9. Device measures static friction of magnetic tape

    Science.gov (United States)

    Cole, P. T.

    1967-01-01

    Device measures the coefficient of static friction of magnetic tape over a range of temperatures and relative humidities. It uses a strain gage to measure the force of friction between a reference surface and the tape drawn at a constant velocity of approximately 0.0001 inch per second relative to the reference surface.

  10. Bending strain study of Bi-2223/Ag tapes using Hall sensor magnetometry

    International Nuclear Information System (INIS)

    Lahtinen, M.; Paasi, J.; Sarkaniemi, J.; Han, Z.; Freltoft, T.

    1996-01-01

    The influence of room temperature bending on critical current (I c ) of Bi-2223/Ag tapes is studied by Hall sensor magnetometry, four-point method and scanning electron microscopy. Hall sensor magnetometry allows one to assess tape homogeneity and the amount of mechanical damage caused by bending. The microstructure of the Bi-2223 ceramic is found to strongly affect the tape behavior under bending strain. In a tape with moderate I c = 6.1 A at 77 K and a porous ceramic core, crack propagation took place normal to the Ag-ceramic interface, whereas in tapes with dense core, I c above 10 A at 77 K, cracks propagated in the tape plane. In monofilamentary tapes core homogeneity correlated with good bending strain performance. In multifilamentary tapes crack propagation between filaments was prohibited by the Ag matrix, thus leading to enhanced strain tolerance. In the high I c tapes studied, bending to 25 mm radius resulted in 1%--2% I c degradation

  11. Lending Video Game Consoles in an Academic Library

    Science.gov (United States)

    Buller, Ryan

    2017-01-01

    This paper will outline the process and discussions undertaken at the University of Denver's University Libraries to implement a lending service providing video game consoles. Faculty and staff at the University Libraries decided to pursue the new lending service, though not a traditional library offering, to support the needs of a video game…

  12. E-Approval Plans in Research Libraries

    Science.gov (United States)

    Pickett, Carmelita; Tabacaru, Simona; Harrell, Jeanne

    2014-01-01

    Research libraries have long invested in approval plan services, which offer an economical way to acquire scholarly and scientific publications. Traditional approval plans have evolved and now enable libraries to expand their e-book offerings to better serve researchers. Publishers offer a myriad of e-book purchasing options. These range from…

  13. Graduate Student Needs in Relation to Library Research Skills

    Science.gov (United States)

    Young, Shawna; Jacobs, Warren

    2013-01-01

    Traditionally, graduate study includes a research component, requiring library skills to locate relevant literature. Upon matriculation into graduate programs, many students are underprepared in library research skills, making library instruction a priority for the success of graduate students. This qualitative study, utilizing emergent design,…

  14. Simulation and analysis of tape spring for deployed space structures

    Science.gov (United States)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  15. Buffer layers grown by replicating the texture of an original template tape

    International Nuclear Information System (INIS)

    Lim, Sunme; Yoo, Jaeun; Park, Chan; Youm, Dojun

    2007-01-01

    We propose a fabrication method of the buffer layers, whose biaxial textures are replicated from an original template tape. The purpose of this method is economical texturing process for coated conductors. At first we prepared a biaxially textured metal tape (TM-tape). Then a sacrifice layer (SA), a buffer layer (BU) and a thick metallic layer (SM) were sequentially deposited on the TM-tape. SA-layer and BU-layer were deposited epitaxially to copy the texture of the TM-tape. SA-layer was dissoluble in water. SM-layer with the textured BU-layer was separated and could be used for a supporting tape for the further growth of a superconducting layer. In this way, it is possible to reuse the original textured TM-tape many times. In this paper, we report the results of our experiments, in which we used a biaxially Ni tape, BaO film, STO film, and a thick Ag film for TM-tape, SA-layer, BU-layer, and SM-layer, respectively. The Ag/STO layers were successfully separated form the Ni tape by dissolving the BaO layer in water. The texture quality of the STO layer was well secured after the separation

  16. Access of Digitized Print Originals in US and UK Higher Education Libraries Combined with Print Circulation Indicates Increased Usage of Traditional Forms of Reading Materials. A Review of: Joint, Nicholas. “Is Digitisation the New Circulation?: Borrowing Trends, Digitisation and the nature of reading in US and UK Libraries.” Library Review 57.2 (2008: 87-95.

    Directory of Open Access Journals (Sweden)

    Kurt Blythe

    2009-03-01

    libraries, while it is up in the non-ARL higher education libraries represented and in UK higher education libraries. However, audio book circulation in US public libraries supplements print circulation to the point where overall circulation of book materials is increasing, and the access of digital literature supplements print circulation in ARL member libraries (although the statistics are difficult to measure and meld with print circulation statistics. Essentially, the circulation of book material is increasing in most institutions when all formats are considered. According to the author, library patrons are reading more than ever; the materials patrons are accessing are traditional in content regardless of the means by which the materials are accessed.Conclusion – The author contends that print circulation is in decline only where digitization efforts are extensive, such as in ARL-member libraries; when digital content is factored into the equation the access of book-type materials is up in most libraries. The author speculates that whether library patrons use print or digital materials, the content of those materials is largely traditional in nature, thereby resulting in the act of “literary” reading remaining a focal point of library usage. Modes of reading and learning have not changed, at least insofar as these things may be inferred from studying circulation statistics. The author asserts that digital access is favorable to patrons and that libraries should attempt to follow the ARL model of engaging in large scale digitization projects in order to provide better service to their patrons; the author goes on to argue that UK institutions with comparable funding to ARLs will have greater success in this endeavour if UK copyright laws are relaxed.

  17. A Digital Library Example in the Digital Age: İstanbul Bilgi University Library and e-Resources

    Directory of Open Access Journals (Sweden)

    Banu Elçi

    2015-06-01

    Full Text Available This article describes the ongoing of the traditional library and service concept alteration to the library and service concept of the digital age and refers to an instance as İstanbul Bilgi University Library and e-Resources that pioneers technological advances and digital applications to be integrated into the library field. In this sense it involves services, developments, applications and projects provided by Bilgi Libraries.This article also accounts for a number of works which integrated digital resources and applications and social network interactions of the internet and the web of the digital age and how they are adjusted to the library area.In this context, it refers to an evolvement of a different approach of libraries and enhacements diverged from customary and adopted library service concepts and reveals through the medium of samples from İstanbul Bilgi University Library and e-Resources.

  18. Overcurrent experiments on HTS tape and cable conductor

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Jensen, Kim Høj; Træholt, Chresten

    2001-01-01

    their critical current. In this light, it is important to investigate the response of HTS tapes and cable conductors to overcurrents several times the critical current. A number of experiments have been performed on HTS tapes and cable conductors, with currents up to 20 times the critical current. During...... overcurrent experiments, the voltage, and the temperature were measured as functions of time in order to investigate the dynamic behavior of the HTS tape and cable conductor. After each experiment, damage to the superconductors was assessed by measuring the critical current. Preliminary results show...... that within seconds an HTS tape (critical current=17 A) heats above room temperature with an overcurrent larger than 140 A. Similar overcurrent experiments showed that a HTS cable conductor could sustain damage with overcurrents exceeding 10 times the critical current of the cable conductor....

  19. Superconducting flat tape cable magnet

    Science.gov (United States)

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  20. Academic Digital Library Construction Evaluation: Measures and Approaches

    OpenAIRE

    Wang , Qiyun

    2008-01-01

    Through review norms, standards and practice related to academic digital library construction evaluation at home and abroad, on the basis of investigation and study on the digital library evaluation at home and abroad, for status quo of the academic digital library construction, using qualitative analysis and quantitative analysis method, with methods and indicators for the traditional library evaluation system as a reference coordinates, put forward a comprehensive evaluation index system of...

  1. Methods of Measuring Stress Relaxation in Composite Tape Springs

    Science.gov (United States)

    2015-03-26

    10 3. Cure Cycle Recommended for Patz F7 Prepreg . . . . . . . . . . . . . . . . . . . . . 17 4. Typical Stress...unique and dimensionally complex parts. Hand lay-up is the method by which prepreg tape or fibers are laid down and then the matrix is then ‘painted’ on...structure. Hand lay-up using a prepreg tape stands out as the inexpensive choice for the unique low number production of tape springs and should

  2. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    Science.gov (United States)

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  3. Ankle taping does not impair performance in jump or balance tests.

    Science.gov (United States)

    Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.

  4. Pediatric Tape: Accuracy and Medication Delivery in the National Park Service

    Directory of Open Access Journals (Sweden)

    Danielle D. Campagne

    2015-10-01

    Full Text Available Introduction: The objective is to evaluate the accuracy of medication dosing and the time to medication administration in the prehospital setting using a novel length-based pediatric emergency resuscitation tape. Methods: This study was a two-period, two-treatment crossover trial using simulated pediatric patients in the prehospital setting. Each participant was presented with two emergent scenarios; participants were randomized to which case they encountered first, and to which case used the National Park Service (NPS emergency medical services (EMS length-based pediatric emergency resuscitation tape. In the control (without tape case, providers used standard methods to determine medication dosing (e.g. asking parents to estimate the patient’s weight; in the intervention (with tape case, they used the NPS EMS length-based pediatric emergency resuscitation tape. Each scenario required dosing two medications (Case 1 [febrile seizure] required midazolam and acetaminophen; Case 2 [anaphylactic reaction] required epinephrine and diphenhydramine. Twenty NPS EMS providers, trained at the Parkmedic/Advanced Emergency Medical Technician level, served as study participants. Results: The only medication errors that occurred were in the control (no tape group (without tape: 5 vs. with tape: 0, p=0.024. Time to determination of medication dose was significantly shorter in the intervention (with tape group than the control (without tape group, for three of the four medications used. In case 1, time to both midazolam and acetaminophen was significantly faster in the intervention (with tape group (midazolam: 8.3 vs. 28.9 seconds, p=0.005; acetaminophen: 28.6 seconds vs. 50.6 seconds, p=0.036. In case 2, time to epinephrine did not differ (23.3 seconds vs. 22.9 seconds, p=0.96, while time to diphenhydramine was significantly shorter in the intervention (with tape group (13 seconds vs. 37.5 seconds, p<0.05. Conclusion: Use of a length-based pediatric emergency

  5. The virtual library: Coming of age

    Science.gov (United States)

    Hunter, Judy F.; Cotter, Gladys A.

    1994-01-01

    With the high speed networking capabilities, multiple media options, and massive amounts of information that exist in electronic format today, the concept of a 'virtual' library or 'library without walls' is becoming viable. In virtual library environment, the information processed goes beyond the traditional definition of documents to include the results of scientific and technical research and development (reports, software, data) recorded in any format or media: electronic, audio, video, or scanned images. Network access to information must include tools to help locate information sources and navigate the networks to connect to the sources, as well as methods to extract the relevant information. Graphical User Interfaces (GUI's) that are intuitive and navigational tools such as Intelligent Gateway Processors (IGP) will provide users with seamless and transparent use of high speed networks to access, organize, and manage information. Traditional libraries will become points of electronic access to information on multiple medias. The emphasis will be towards unique collections of information at each library rather than entire collections at every library. It is no longer a question of whether there is enough information available; it is more a question of how to manage the vast volumes of information. The future equation will involve being able to organize knowledge, manage information, and provide access at the point of origin.

  6. The occupational therapist as a consultant on a university library layout adequacy

    Directory of Open Access Journals (Sweden)

    Iranise Moro Pereira Jorge

    2016-07-01

    Full Text Available Objective: This article aims to present the diagnosis, development and planning of the Universidade Federal do Paraná library layout – UFPR campus of Rebouças, located in the city of Curitiba. Method: We adopted a methodological approach of qualitative nature and exploratory descriptive character using, initially, the physical-environmental analysis with Ergonomics (NR 17 and Accessibility (NBR 9050 guiding principles. The library diagnosis was then performed using data collected through observations in the library plant, photo camera records and measurements taken with a measuring tape. Results: Based on the results from the library environment analysis, it was verified the need for adjustments as the evaluated environments did not meet the reference guidelines used. Thus, in order to implement the interventions proposed by the researchers, the University Engineering, Maintenance and Joinery department helped to make this environment accessible and appropriate to future users and library workers. Conclusion: The study highlights that the possibility environment adapting before the operation favors a work space adequate to the development of the tasks, a work organization and maintenance of the users’ health, which will contribute to a satisfactory occupational performance when using this environment

  7. Delamination behaviour in differently copper laminated REBCO coated conductor tapes under transverse loading

    Energy Technology Data Exchange (ETDEWEB)

    Gorospe, Alking [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Department of Engineering, Aurora State College of Technology, Baler Aurora 3200 (Philippines); Nisay, Arman [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Shin, Hyung-Seop, E-mail: hsshin@andong.ac.kr [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of)

    2014-09-15

    Highlights: • I{sub c} degradation behavior under transverse tension loading in different CC tape structure. • Weibull distribution analysis applied on delamination mechanism of CC tape. • Delamination mechanism on CC tapes depending on copper lamination type. • SEM and WDS mapping analysis of delamination sites under transverse loading. - Abstract: Laminated HTS coated conductor (CC) tapes having a unique multi-layer structure made them vulnerable when exposed to transverse loading. Electromechanical transport properties of these CC tapes can be affected by excessive transverse stresses. Due to the coefficient of thermal expansion (CTE) mismatch and incompatibility among constituent materials used in coil applications, delamination among layers occurs and causes critical current, I{sub c} degradation in the CC tapes. In this study, the delamination behaviors in copper (Cu) solder-laminated CC tapes by soldering and surround Cu-stabilized ones by electroplating under transverse tension loading were investigated. Similarly to the surround Cu-stabilized CC tapes in our previous reports, the Cu solder-laminated CC tapes also showed an abrupt and gradual I{sub c} degradation behavior. However, the Cu solder-laminated CC tapes showed different delamination morphologies as compared to the surround Cu-stabilized CC tapes; the superconducting side and the substrate side of the Cu solder laminated CC tapes were totally separated by delamination. On the other hand, the brass laminate did not show any significant effect on the delamination strength when it is added upon the surround Cu-stabilized CC tapes.

  8. Adhesive tape exfoliation

    DEFF Research Database (Denmark)

    Bohr, Jakob

    2015-01-01

    Single-crystal graphite can be cleaved by the use of an adhesive tape. This was also the initial route for obtaining graphene, a one-layer thick graphite slab. In this letter a few simple and fun considerations are presented in an attempt to shed some light on why this procedure is successful...

  9. The Library: from classic to postmodern

    OpenAIRE

    Petre, Maria Carmen Nadia

    2010-01-01

    In its long and irregular transition, from traditional library to the electronic book we have seen combining and alternating the hybrid, electronic and most recently the digital libraries. All these concepts which are combining and are conditioning each other, are referring to methods of organization and use of an informational content (which exists or not in an informational structure).

  10. Kinesio® Tape Barrier Does Not Inhibit Intramuscular Cooling During Cryotherapy.

    Science.gov (United States)

    Lyman, Katie J; McCrone, Michael; Hanson, Thomas A; Mellinger, Christopher D; Gange, Kara

    2018-05-29

    Allied health care professionals commonly apply cryotherapy as treatment for acute musculoskeletal trauma and the associated symptoms. Understanding the impact of a tape barrier on intramuscular temperature can assist in determining treatment duration for effective cryotherapy. To determine whether Kinesio® Tape acts as a barrier that affects intramuscular temperature during cryotherapy application. A repeated-measures, counterbalanced design in which the independent variable was tape application and the dependent variable was muscle temperature as measured by thermocouples placed 1 cm beneath the adipose layer. Additional covariates for robustness were BMI and adipose thickness. University research laboratory. 19 male college students with no contraindications to cryotherapy, no known sensitivity to Kinesio® Tape, and no reported quadriceps injury within the past six months. Topical cryotherapy: crushed-ice bags of 1 kg and 0.5 kg. Intramuscular temperature. The tape barrier had no statistically significant effect on muscle temperature. The pattern of temperature change was indistinguishable between participants with and without tape application. Findings suggest health care professionals can combine cryotherapy with a Kinesio® Tape application without any need for adjustments to cryotherapy duration.

  11. Enhancement of turbulent flow heat transfer in a tube with modified twisted tapes

    Energy Technology Data Exchange (ETDEWEB)

    Lei, Y.G.; Zhao, C.H.; Song, C.F. [College of Environmental Science and Engineering, Taiyuan University of Technology, Taiyuan (China)

    2012-12-15

    Numerical simulations were performed to study the fluid flow and heat transfer in a tube with staggered twisted tapes with central holes. In the range of Reynolds numbers between 6000 and 28 000, the modified twisted tapes increased the Nusselt number by 76.2 {proportional_to} 149.7 % and the friction factor by 380.2 {proportional_to} 443.8 % compared to the smooth tube. Compared to the typical twisted tapes, the modified twisted tapes produced an acceleration flow through the triangle regions leading to the enhancement of heat transfer, and the holes in the modified tapes reduced the severe pressure loss. It was found that the modified twisted tapes decreased the friction factor by 8.0 {proportional_to} 16.1 % and enhanced the heat transfer by 34.1 {proportional_to} 46.8 % in comparison with the typical tapes. These results indicated that the performance ratio values of the tube with modified twisted tapes were higher than 1.0 in the range of Reynolds numbers studied. The computed performance ratios of the tube with modified twisted tapes were much higher than those of the tube with typical twisted tapes. This means that the integrated performance of the tube with staggered twisted tapes with central holes is superior to that of the tube with typical twisted tapes. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. Molten carbonate fuel cell integral matrix tape and bubble barrier

    International Nuclear Information System (INIS)

    Reiser, C.A.; Maricle, D.L.

    1983-01-01

    A molten carbonate fuel cell matrix material is described made up of a matrix tape portion and a bubble barrier portion. The matrix tape portion comprises particles inert to molten carbonate electrolyte, ceramic particles and a polymeric binder, the matrix tape being flexible, pliable and having rubber-like compliance at room temperature. The bubble barrier is a solid material having fine porosity preferably being bonded to the matrix tape. In operation in a fuel cell, the polymer binder burns off leaving the matrix and bubble barrier providing superior sealing, stability and performance properties to the fuel cell stack

  13. Fabrication of laminated Bi-2212/Ag multifilamentary tape

    Science.gov (United States)

    Yuan, D.-W.; Majer, W. J.; Francavilla, T. L.

    2000-03-01

    The powder-in-tube (PIT) process has been successfully used to make long lengths of Ag-sheathed oxide superconductors. A modified PIT approach is proposed to fabricate conductors with laminated Bi-2212 configurations. Ag/Bi-2212 tapes consisting of seven laminae were produced with various thicknesses ranging from 0.38 to 0.25 mm. The use of a turkshead was found to be beneficial, yielding tapes with good dimensional integrity and consistency. Critical current density (Jc ) values greater than 105 A cm-2 (0.01 T and Bicons/Journals/Common/perp" ALT="perp" ALIGN="TOP"/> tape surface) have been attained for tapes of different thicknesses. Nonetheless, Jc was found to be related to the average thickness of individual Bi-2212 lamina. It is believed that excessive cold working accounts for the decrease in Jc with decreasing size below a threshold value. The enhancement of Jc is attributed to the high Bi-2212 grain alignment along the Ag-oxide interfaces and uniform dimensions within the laminate conductors.

  14. Multimedia technologies in university libraries: opportunities and tasks

    Directory of Open Access Journals (Sweden)

    Tavalbekh Serkhan Ali

    2010-03-01

    Full Text Available Multimedia technologies (MMT are considered as a factor of qualitative changes of informational environment of education. Leading role of libraries in the process of integration of MMT environment of university is determined. Influence of libraries experience in usage of informational technologies both traditional and computer-aided, Internet in particular is observed. Determined that introduction of MMT noticeable improving the importance of library in MMT environment organization of universities, improvement of library informational service. Tasks of university libraries with integration into united media space are defining.

  15. Effects of kinesio taping and hot packs on premenstrual syndrome in females.

    Science.gov (United States)

    Choi, Jung-Hyun

    2017-09-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome.

  16. Sputtered thin films for high density tape recording

    NARCIS (Netherlands)

    Nguyen, L.T.

    This thesis describes the investigation of sputtered thin film media for high density tape recording. As discussed in Chapter 1, to meet the tremendous demand of data storage, the density of recording tape has to be increased continuously. For further increasing the bit density the key factors are:

  17. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T.

    2010-10-15

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  18. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T; Nguyen, H. D.; Takehara, K.; Etoh, T. G.

    2010-01-01

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  19. An automated magnetic tape vault at CERN computer center

    CERN Multimedia

    Claudia Marcelloni

    2008-01-01

    The rapidly changing data processing landscape the underlying long-term storage technology remains the tried and tested magnetic tape. This robust and mature technology is used to store the complete LHC data set, from which a fraction of the data is copied to overlying disk caches for fast and widespread access. The handling of the magnetic tape cartridges is now fully automated, as they are racked in vaults where they are moved between the storage shelves and the tape drives by robotic arms.

  20. MILLION BOOK UNIVERSAL DIGITAL LIBRARY PROJECTS: INDIA

    OpenAIRE

    Waghmode, S. S.

    2009-01-01

    Digital Library of India is a digital library of books, which is free-to-read, searchable, predominantly in India languages, available to everyone over the Internet. Very soon it is expected that this portal would provide a gateway to Indian Digital Libraries in Science, Arts, Culture, Music, Movies, Traditional Medicine, Palm Leaves and many more. This project is collaboration between Indian Institute of Science, Bangalore, Universities and Carnegie Mellon University under MILLION BOOK UNIVE...

  1. FENDL/MG. Library of multigroup cross sections in GENDF and MATXS format for neutron-photon transport calculations. Version 1.1 of March 1995. Summary documentation

    International Nuclear Information System (INIS)

    Pashchenko, A.B.; Wienke, H.; Ganesan, S.

    1996-01-01

    Selected neutron reaction nuclear data evaluations and photon-atomic interaction cross section libraries for elements of interest to the IAEA's program on Fusion Evaluated Nuclear Data Library (FENDL) have been processed into GENDF and MATXS format using the NJOY system by R.E. MacFarlane, in VITAMIN-J group structure with VITAMIN-E weighting spectrum. This document summarizes the resulting multigroup data library FENDL/MG version 1.1. The data are available costfree, upon request from the IAEA Nuclear Data Section, online or on magnetic tape. (author). 7 refs, 1 tab

  2. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    OpenAIRE

    Brendon A. Parsons; Olivia Lin Smith; Myeong Chae; Veljko Dragojlovic

    2015-01-01

    Summary In a PTFE tape phase-vanishing reaction (PV-PTFE), a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better...

  3. A new method of measurement of tension on a moving magnetic tape

    Science.gov (United States)

    Kurtinaytis, A. K.; Lauzhinskas, Y. S.

    1973-01-01

    The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

  4. [Efficacy of the application of kinesio tape in patients with stroke].

    Science.gov (United States)

    Ortiz-Ramirez, J; Perez-De la Cruz, S

    2017-02-16

    To review the effects achieved by the kinesio tape in patients with stroke in scientific studies published on date and to discuss these findings may be of interest to neurology. An exhaustive search in the main scientific databases using keywords such as kinesio tape, kinesiotaping, musculoskeletal tape, taping medical concept was carried out. Citations of selected articles and scientific papers published on the website of the Spanish Association of Neuromuscular Bandage were analyzed. Experimental, quasi-experimental, clinical trials and case studies published were used, without limit date, with therapeutical treatment purpose provide important results. Eight articles have met the inclusion criteria. There are eight studies that examine the effect on kinesio tape on lower limb, gait and balance in this kind of therapy, even upper limb and swallowing problems that these patients could present. The kinesio tape in neurological patients can be a complementary technique that empirically provides benefits. However, better methodological quality studies demonstrating the effects attributed to him are still needed.

  5. Recovery of recordings from heat damaged magnetic tapes

    Science.gov (United States)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  6. Modification of critical current in HTSC tape conductors by a ferromagnetic layer

    International Nuclear Information System (INIS)

    Goemoery, F; Souc, J; Seiler, E; Vojenciak, M; Granados, X

    2008-01-01

    In some applications of tape conductors from high temperature superconductors (HTSC) the magnetic field is created by the transported current itself. This is e.g. the case of power transmission cables or current leads. Quite complex distribution of local magnetic field determines then the ability of the superconducting element to carry electrical current. We have investigated how much the critical current of a tape conductor can be changed by putting a ferromagnetic layer in the vicinity of the HTSC material. Numerical procedure has been developed to resolve the current and field distribution in such superconductor-ferromagnet composite tape. Theoretical predictions have been confirmed by experiments on sample made from Bi-2223/Ag composite tape. The critical current of such tape can be improved by placing a soft ferromagnetic material at the tape's edges. On the other hand, the calculations show that the ferromagnetic substrate of YBCO coated tape reduces its self-field critical current

  7. Incorporating Library Provision in School Self-Evaluation

    Science.gov (United States)

    McNicol, Sarah

    2004-01-01

    Traditionally, school libraries have been evaluated primarily in terms of library management; the impact they have on teaching and learning has rarely been a focus. For this reason, they have often been omitted from whole school self-evaluation. Self-evaluation can help schools to prepare for inspection, but more importantly to identify strengths…

  8. How PE tape performs under concrete coating

    International Nuclear Information System (INIS)

    Dritt, H.J.

    1984-01-01

    The program objectives were to evaluate the performance of polyethylene tape plant coating and fusion bonded epoxy powder systems with particular respect to the following: 1. Concrete coating application procedures; 2. The shear resistance during laying and retrieving operations of the coating at the various interfaces (a) Pipe and anti-corrosion coating; (b) Anti-corrosion coating and outerwrap; (c) Overlap areas of the anti-corrosion and outerwrap layers; (d) Between concrete and the various corrosion coatings during laying and retrieving operations. 3. Resistance to damage of the coating as a consequence of cracking or slippage of the concrete weight coating. 4. Ability of various coatings to withstand the damage during concrete application by both impact and compression methods; 5. Evaluation of tape and shrink sleeve joint coatings at the cut-back area as well as performance of tape under hot asphalt coating

  9. The Research Funding Service: a model for expanded library services

    OpenAIRE

    Means, Martha L.

    2000-01-01

    Traditionally, libraries have provided a modest amount of information about grants and funding opportunities to researchers in need of research funding. Ten years ago, the University of Washington (UW) Health Sciences Libraries and Information Center joined in a cooperative effort with the School of Medicine to develop a complete, library-based grant and funding service for health sciences researchers called the Research Funding Service. The library provided space, access to the library colle...

  10. Outcome of transvaginal mesh and tape removed for pain only.

    Science.gov (United States)

    Hou, Jack C; Alhalabi, Feras; Lemack, Gary E; Zimmern, Philippe E

    2014-09-01

    Because there is reluctance to operate for pain, we evaluated midterm outcomes of vaginal mesh and synthetic suburethral tape removed for pain as the only indication. After receiving institutional review board approval we reviewed a prospective database of women without a neurogenic condition who underwent surgery for vaginal mesh or suburethral tape removal with a focus on pain as the single reason for removal and a minimum 6-month followup. The primary outcome was pain level assessed by a visual analog scale (range 0 to 10) at baseline and at each subsequent visit with the score at the last visit used for analysis. Parameters evaluated included demographics, mean time to presentation and type of mesh or tape inserted. From 2005 to 2013, 123 patients underwent surgical removal of mesh (69) and suburethral tape (54) with pain as the only indication. Mean followup was 35 months (range 6 to 59) in the tape group and 22 months (range 6 to 47) in the mesh group. The visual analog scale score decreased from a mean preoperative level of 7.9 to 0.9 postoperatively (p = 0.0014) in the mesh group and from 5.3 to 1.5 (p = 0.00074) in the tape group. Pain-free status, considered a score of 0, was achieved in 81% of tape and 67% of mesh cases, respectively. No statistically significant difference was found between the groups. When pain is the only indication for suburethral tape or vaginal mesh removal, a significant decrease in the pain score can be durably expected after removal in most patients at midterm followup. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    Directory of Open Access Journals (Sweden)

    Brendon A. Parsons

    2015-06-01

    Full Text Available In a PTFE tape phase-vanishing reaction (PV-PTFE, a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better describe the process of solvent transport in PV-PTFE bromination reactions. Though PTFE tape has been reported as impermeable to some compounds, such as dimethyl phthalate, solvent adsorption to the tape altered its permeability and allowed diffusion through channels of solvent within the PTFE tape. In this case, the solvent-filled pores of the PTFE tape are chemically more akin to the adsorbed solvent rather than to the PTFE fluorous structure. The solvent uptake effect, which was frequently observed in the course of PV-PTFE reactions, can be related to the surface tension of the solvent and the polarity of the solvent relative to the reagent. The lack of pores in bulk PTFE prevents solvents from altering its permeability and, therefore, bulk PTFE is impermeable to most solvents and reagents. However, bromine, which is soluble in liquid fluorous media, diffused through the bulk PTFE. A better understanding of the PTFE phase barrier will make it possible to further optimize the PV-PTFE reaction design.

  12. POSTOPERATIVE URINARY RETENTION AND EARLY REPOSITION OF TENSION-FREE VAGINAL TAPE

    Directory of Open Access Journals (Sweden)

    Marijan Lužnik

    2003-12-01

    Full Text Available Background. The purpose of this article is to show a possible method of treatment of postoperative urinary retention after an initial tension-free vaginal tape.Methods. From December 1999 to May 2003 we performed one hundred TVT procedures at our department, among them five women had postoperative urinary retention evaluated with catheterization. Revision and reposition of tension-free vaginal tape were performed if retention of urine was over 100 ml.Results. Urinary retention after an initial tension-free vaginal tape was successfully treated by early reposition of tension-free vaginal tape. This resulted in immediate residualfree voiding and continence, which remained unchanged at 6 week and 3 month follow-up.Conclusions. Postoperative urinary retention may be treated by reposition instead of dissection or elongation of the tension-free vaginal tape.

  13. White House Tapes of the Nixon Administration, 1971 to 1973

    Data.gov (United States)

    National Archives and Records Administration — This dataset provides information about the Nixon Administration's White House Tapes. The White House Tapes contain sound recordings of President Richard Nixon's...

  14. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an adhesive tape solvent is a device that consists of a liquid such as 1,1,2-trichloro-1,2,2-trifluoroethane...

  15. Development of library documents in BRICEM on network-based environment

    International Nuclear Information System (INIS)

    Gao Renxi

    2010-01-01

    With the development of the internet, the transformation from a traditional library to a modem one is essential to the development of BRICEM (Beijing Research Institute of Chemical Engineering and Metallurgy) Technology Library and the situations of other libraries, this thesis integrates the reality of BRICEM and its library in an effort to work out a tentative plan, as well as concrete measures and procedures of digitalising and online-sharing the resources of BRICEM Technology Library. (author)

  16. Accelerated aging studies and environmental stability of prototype tamper tapes

    Energy Technology Data Exchange (ETDEWEB)

    Wright, B.W.; Wright, C.W. [Pacific Northwest Lab., Richland, WA (United States); Bunk, A.R. [Battelle Columbus Lab., OH (United States)] [and others

    1995-05-01

    This report describes the results of accelerated aging experiments (weathering) conducted on prototype tamper tapes bonded to a variety of surface materials. The prototype tamper tapes were based on the patented Confirm{reg_sign} tamper-indicating technology developed and produced by 3M Company. Tamper tapes bonded to surfaces using pressure sensitive adhesive (PSA) and four rapid-set adhesives were evaluated. The configurations of the PSA-bonded tamper tapes were 1.27-cm-wide Confirm{reg_sign} 1700 windows with vinyl underlay and 2.54-cm-wide Confirm{reg_sign} 1700 windows with vinyl and polyester underlays. The configurations of the rapid-set adhesive-bonded tamper tapes were 2.54-cm-wide Confirm{reg_sign} (1700, 1500 with and without primer, and 1300) windows with vinyl underlay. Surfaces used for bonding included aluminum, steel, stainless steel, Kevlar{reg_sign}, brass, copper, fiberglass/resin with and without gel coat, polyurethane-painted steel, acrylonitrile:butadiene:styrene plastic, polyester fiberglass board, Lexan polycarbonate, and cedar wood. Weathering conditions included a QUV cabinet (ultraviolet light at 60{degrees}C, condensing humidity at 40{degrees}C), a thermal cycling cabinet (-18{degrees}C to 46{degrees}C), a Weather-O-Meter (Xenon lamp), and exposure outdoors in Daytona Beach, Florida. Environmental aging exposures lasted from 7 weeks to 5 months. After exposure, the tamper tapes were visually examined and tested for transfer resistance. Tamper tapes were also exposed to a variety of chemical liquids (including organic solvents, acids, bases, and oxidizing liquids) to determine chemical resistance and to sand to determine abrasion resistance.

  17. Red Tape dan Perilaku Masyarakat dalam Pelayanan Izin Usaha Perdagangan di Kota Makassar

    OpenAIRE

    Lukman, Lukman

    2015-01-01

    : Red tape as pathology has long been the focus of an expert study of bureaucracy. Early scholarly attempts conceptualized red tape at the individual level as in Merton's classic thesis (1940) about goal displacement. Waldo (1946) one man's red tape is another man's system. Kaufman (1977) one person's red tape may be another's treasured safeguard. Osborne and Gaebler (1992) good people trapped in bad systems. Bozeman and Feneey (2011) red tape is often used as a synonym of the term procedures...

  18. Delamination behaviour of GdBCO coated conductor tapes under transverse tension

    International Nuclear Information System (INIS)

    Gorospe, A.; Nisay, A.; Dizon, J.R.; Shin, H.S.

    2013-01-01

    Highlights: •Installation of a test frame which gives precisely aligned transverse load. •Investigation of I c degradation behaviour depending on the type of sample delamination. •Inhomogeneity of the CC tapes caused large variation on delamination strength. •SEM and EDS analysis of delamination sites under transverse loading. -- Abstract: The electromechanical property behaviour of 2G coated conductor (CC) tapes fabricated by multi-layer deposition process both in the in-plane and transverse direction should be understood. The CC tapes are used in the fabrication of epoxy resin-impregnated coils. In such case, the Lorentz force due to the high magnetic field applied as well as the thermal stress due to the difference in coefficient of thermal expansion (CTE) among constituent layers during cooling to cryogenic temperature will induce transversely applied load to the surface of CC tapes in coils. Hence, the CC tape should have a good mechanical property in the transverse direction in order to maintain its superior performance under magnetic field. In this study, a test frame which gives precisely aligned transverse load was devised. Using the fixture, the delamination behaviours including the delamination strength of the GdBCO CC tapes under transverse tensile loading were investigated. Large variation on the delamination strength of the CC tapes was recorded and might have resulted from the slit edge effect and the inhomogeneity of the CC tapes. The I c degradation behaviour under transverse load was related to the location where delamination occurred in the sample

  19. Dynamic response of HTS composite tapes to pulsed currents

    International Nuclear Information System (INIS)

    Meerovich, V; Sokolovsky, V; Prigozhin, L; Rozman, D

    2006-01-01

    Dynamic voltage-current characteristics of an HTS Ag/BiSCCO composite tape are studied both experimentally and theoretically. The tape is subjected to pulsed currents with different shapes and magnitudes and voltage traces are measured using the four-point method with different locations of potential taps on the sample surface. Clockwise and anticlockwise hysteresis loops are obtained for the same sample depending on the location of the potential taps. The dynamic characteristics deviate substantially from the DC characteristic, especially in the range of low voltages where a criterion for the critical current value is usually chosen (1-10 μV cm -1 ). The critical current determined from dynamic characteristics and its change with the pulse magnitude depend on the location of the potential taps and on the curve branch chosen for the critical current determination (ascending or descending). The theoretical analysis is based on a model of the magnetic flux diffusion into a composite tape for a superconductor described by the flux creep characteristic. Numerical simulation based on this model gives results in good agreement with the experimental ones and explains the observed peculiarities of the dynamic characteristics of HTS composite tapes. The difference between the magnetic diffusion into a tape and a slab is discussed

  20. ANKLE TAPING DOES NOT IMPAIR PERFORMANCE IN JUMP OR BALANCE TESTS

    Directory of Open Access Journals (Sweden)

    Javier Abián-Vicén

    2008-09-01

    Full Text Available This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96. The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed

  1. Study on influence of irradiation vulcanization to silicon rubber autohesive tape's properties

    International Nuclear Information System (INIS)

    Chen Chun; Tang Jian; Wu Ling; Han Yingchun; Zhou Hong; Mo Yan; Fu Haijun

    2006-01-01

    After using 60 Co γ-ray to irradiate vulcanization silicon rubber autohesive tape, the effect of absorbed dose to the autohesive tape's tensile strength, elongation at break, autohesion and breakdown voltage strength and dose rate's effect to the autohesive tape's properties were studied. The results indicate that autohesive tape's tensile strength increases and the elongation at break decreases with the increasing dose. Under the dose of 25 kGy, the tape's autohesion increases with the increasing dose. When the dose is up to 25 kGy, the tape's autohesion achieves to the maximum, and then decreases with the increasing dose. Absorbed dose has no effect to the tape's breakdown voltage strength, and the dose rate has no effect to the autohesive tape's properties. (authors)

  2. Kinesio Taping to generate skin convolutions is not better than sham taping for people with chronic non-specific low back pain: a randomised trial

    Directory of Open Access Journals (Sweden)

    Patrícia do Carmo Silva Parreira

    2014-06-01

    Full Text Available Question: For people with chronic low back pain, does Kinesio Taping, applied according to the treatment manual to create skin convolutions, reduce pain and disability more than a simple application without convolutions? Design: Randomised trial with concealed allocation, intention-to-treat analysis and blinded assessment of some outcomes. Participants: 148 participants with chronic non-specific low back pain. Intervention: Experimental group participants received eight sessions (over four weeks of Kinesio Taping applied according to the Kinesio Taping Method treatment manual (ie, 10 to 15% tension applied in flexion to create skin convolutions in neutral. Control group participants received eight sessions (over four weeks of Kinesio Taping with no tension, creating no convolutions. Outcome measures: The primary outcome measures were pain intensity and disability after the four-week intervention. Secondary outcomes were pain intensity and disability 12 weeks after randomisation, and global perceived effect at both four and 12 weeks after randomisation. Results: Applying Kinesio Tape to create convolutions in the skin did not significantly change its effect on pain (MD–0.4 points, 95% CI–1.3 to 0.4 or disability (MD–0.3 points, 95% CI–1.9 to 1.3 at four weeks. There was a small difference in favour of the experimental group for the secondary outcome of global perceived effect (MD 1.4 points, 95% CI 0.3 to 2.5 at four weeks. No significant between-group differences were observed for the other secondary outcomes. Conclusion: Kinesio Taping applied with stretch to generate convolutions in the skin was no more effective than simple application of the tape without tension for the outcomes measured. These results challenge the proposed mechanism of action of this therapy. Trial registration: Brazilian Registry of Clinical Trials, RBR-7ggfkv. [Parreira PCS, Costa LCM, Takahashi R, Hespanhol Junior LC, da Luz Junior MA, da Silva TM, Costa LOP

  3. CLEARANCE OF ARCHIVE TAPE VAULT (BUILDING 186)

    CERN Multimedia

    EP Division

    1999-01-01

    The archive tape vault is being cleared to make way for the LHC experiments silicon facility.Experiments were contacted in February to arrange for the extended storage or destruction of archived volumes. Any who have not yet done so are asked to contactR. Minchin/IT immediately.This is also an opportunity to clear unused tapes or cartridges from around the site and have them destroyed ecologically. Please contact ep.smi.helpdesk@cern.ch to arrange for collection.A.E. Ball/EP-SMI

  4. Analysis of the Paradigm Evolution of Digital Libraries in China

    Directory of Open Access Journals (Sweden)

    Tan Sun

    2007-10-01

    Full Text Available The authors analyze the developmental framework of digital libraries in China and point out their current demand characteristics, development requirements, and developmental period. They then conclude that it is necessary to start up a new paradigm evolution of a digital library, from a traditional digital library to a virtual digital library. On that basis, they describe in detail several problems and developmental approaches that developing a virtual digital library must deal with, drawing lessons from the prototype DILIGENT.

  5. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    Energy Technology Data Exchange (ETDEWEB)

    Grin, A. [Building Science Corporation, Somerville, MA (United States); Lstiburek, J. [Building Science Corporation, Somerville, MA (United States)

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  6. New Aspects of Library Design

    Directory of Open Access Journals (Sweden)

    Tina Hohmann

    2006-07-01

    Full Text Available New planning principles are required to meet the changing needs of the users of the library of the future. The digital revolution has changed the appearance of today’s libraries entirely. The majority of today’s information resources are of a non-physical nature and accessing information is more varied and complex. The traditional role as asset keeper is one of many tasks today. The recently completed examples of Dresden and Göttingen State- and University Library, the Seattle Public Library and the Idea Stores in London, all of them highly popular and frequented, show current trends in library design. What do they offer their visitors? access to information guidance (information skills possibility for communication working environment inspiring atmosphere Their design is based on the following main principles: Access to the library and its medias should be obvious and easy for everybody. There should be multifarious space for formal and informal communication between customers and staff. The interior should offer an attractive and comfortable environment for both customers and staff. The library building should adequately represent its institutional philosophy and aims. Its building design, structure and appliances should give consideration to sustainability.

  7. Graduate and Post-MLS Study in Digital Libraries

    Science.gov (United States)

    Blummer, Barbara

    2005-01-01

    As librarians confront the Information Age, it is imperative that they remain aware of the issues that affect the profession. Traditional library skills are no longer adequate for maintaining a competitive edge in the field. Post-graduate education in digital libraries offers information professionals an opportunity to broaden their knowledge of…

  8. E-Government: Issues and Implications for Public Libraries

    Science.gov (United States)

    Berryman, Jennifer

    2004-01-01

    Reviews the literature of e-government deployment world-wide, focussing on two possible roles for public libraries in e-government. The first is a continuation of their traditional role of information provision and managing library transactions electronically and the second, a move to handling government business transactions as well. Identifies…

  9. Design for manufacturability of a VDSM standard cell library

    International Nuclear Information System (INIS)

    Zhou Chong; Zeng Jianping; Chen Lan; Yin Minghui; Zhao Jie

    2012-01-01

    This paper presents a method of designing a 65 nm DFM standard cell library. By reducing the amount of the library largely, the process of optical proximity correction (OPC) becomes more efficient and the need for large storage is reduced. This library is more manufacture-friendly as each cell has been optimized according to the DFM rule and optical simulation. The area penalty is minor compared with traditional library, and the timing, as well as power has a good performance. Furthermore, this library has passed the test from the Technology Design Department of Foundry. The result shows this DFM standard cell library has advantages that improve the yield. (semiconductor integrated circuits)

  10. Mirror-Touch and Ticker Tape Perceptions in Synesthesia

    Directory of Open Access Journals (Sweden)

    Charlotte Anne Chun

    2013-11-01

    Full Text Available A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia’s connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person’s arm being stroked can evoke physical touch sensation on one’s own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker’s mouth. To explore synesthesia’s associations with these phenomena, a diverse group (n=3,743 was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1,017 eligible respondents, synesthetes (across all subtypes reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However effect size was small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2 to 4% and sequence-space synesthesia (9 to 14%. Within synesthesia, grapheme-personification, also called ordinal-linguistic personification was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect

  11. Content Management for the Virtual Library

    Directory of Open Access Journals (Sweden)

    Ed Salazar

    2006-09-01

    Full Text Available Traditional, larger libraries can rely on their physical collection, coffee shops, and study rooms as ways to entice patrons into their library. Yet virtual libraries merely have their online presence to attract students to resources. This can only be achieved by providing a fully functional site that is well designed and organized, allowing patrons to navigate and locate information easily. One such technology significantly improving the overall usefulness of Web sites is a content management system (CMS. Although the CMS is not a novel technology per se, it is a technology smaller libraries cannot afford to ignore. In the fall of 2004, the Northcentral University Electronic Learning Resources Center (ELRC, a small, virtual library, moved from a static to a database-driven Web site. This article explains the importance of a CMS for the virtual or smaller library and describes the methodology used by ELRC to complete the project.

  12. Comparison of Iranian National Medical Library with digital libraries of selected countries.

    Science.gov (United States)

    Zare-Farashbandi, Firoozeh; Najafi, Nayere Sadat Soleimanzade; Atashpour, Bahare

    2014-01-01

    The important role of information and communication technologies and their influence on methods of storing, retrieving information in digital libraries, has not only changed the meanings behind classic library activates but has also created great changes in their services. However, it seems that not all digital libraries provide their users with similar services and only some of them are successful in fulfilling their role in digital environment. The Iranian National Medical library is among those that appear to come short compared to other digital libraries around the world. By knowing the different services provided by digital libraries worldwide, one can evaluate the services provided by Iranian National Medical library. The goal of this study is a comparison between Iranian National Medical library and digital libraries of selected countries. This is an applied study and uses descriptive - survey method. The statistical population is the digital libraries around the world which were actively providing library services between October and December 2011 and were selected by using the key word "Digital Library" in Google search engine. The data-gathering tool was direct access to the websites of these digital libraries. The statistical study is descriptive and Excel software was used for data analysis and plotting of the charts. The findings showed that among the 33 digital libraries investigated worldwide, most of them provided Browse (87.87%), Search (84.84%), and Electronic information retrieval (57.57%) services. The "Help" in public services (48/48%) and "Interlibrary Loan" in traditional services (27/27%) had the highest frequency. The Iranian National Medical library provides more digital services compared to other libraries but has less classic and public services and has less than half of possible public services. Other than Iranian National Medical library, among the 33 libraries investigated, the leaders in providing different services are Library of

  13. String and Sticky Tape Experiments.

    Science.gov (United States)

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  14. JEF-2.2. The evaluated neutron nuclear data library of the NEA Data Bank. Summary of contents

    International Nuclear Information System (INIS)

    Lemmel, H.D.; Schwerer, O.

    1996-01-01

    This document summarizes the contents of JEF-2.2, the Joint Evaluated File of neutron nuclear data compiled by the OECD Nuclear Energy Agency Data Bank, finalized in 1992 and released in 1993. The entire library or retrievals of selected materials are available from the IAEA Nuclear Data Section free of charge, either on magnetic tape, or online from NDIS, the interactive Nuclear Data Information System. (author)

  15. On the weld strength of in situ tape placed reinforcements on weave reinforced structures

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Rietman, Bert; Akkerman, Remko

    2012-01-01

    Unidirectionally reinforced thermoplastic tapes were welded onto woven fabric reinforced laminates using a laser assisted tape placement process. A mandrel peel setup was used to quantify the interfacial fracture toughness between the tape and the laminate as a measure for weld strength. The tape

  16. Library information sharing. Best practices and trends. Challenges and prospects

    Directory of Open Access Journals (Sweden)

    Posner Beth

    2017-12-01

    Full Text Available Libraries share information with each other, through interlibrary loan services, so that their library users can access more of the world of information than is available in any one library. When supported with enough budget, staff and authority to do so, library resource sharing specialists can facilitate information access in a variety of traditional and innovative ways, including and beyond lending and borrowing print and digital information. Best practices, trends and new solutions for library resource sharing are reviewed. International cooperation is also highlighted.

  17. VHS-tape system for general purpose computer. For next generation mass storage system

    International Nuclear Information System (INIS)

    Ukai, K.; Takano, M.; Shinohara, M.; Niki, K.; Suzuki, Y.; Hamada, T.; Ogawa, M.

    1994-07-01

    Mass storage is one of the key technology of next generation computer system. A huge amount of data is produced on a field of particle and nuclear physics. These data are raw data of experiments, analysis data, Monte Carlo simulations data, etc. We search a storage device for these data at the point of view of capacity, price, size, transfer speed, etc. We have selected a VHS-tape (12.7 mm-tape, helical scan) from many storage devices. Characteristics of the VHS-tape are as follows; capacity of 14.5 GB, size of 460 cm 3 , price of 1,000 yen (S-VHS tape for video use), and 1.996 MB/sec transfer speed at a sustained mode. Last year, we succeeded to operate the VHS-tape system on a workstation as a I/O device with read/write speed of 1.5 MB/sec. We have tested a VHS-tape system by connecting to the channel of the general purpose computer (Fujitsu M-780/10S) in our institute. We obtained a read and write speeds of 1.07 MB/sec and 1.72 MB/sec by FORTRAN test programs, respectively. Read speeds of an open reel tape and a 3480 type cassete tape by the same test programs are 1.13 MB/sec and 2.54 MB/sec, respectively. Speeds of write operation are 1.09 MB/sec and 2.54 MB/sec for the open reel and 3480 cassete tape, respectively. A start motion of the VHS-tape for read/write operations needs about 60 seconds. (author)

  18. Students' Perception on Library Service Quality: A Qualitative Study of IIUM Library

    Science.gov (United States)

    Ahmed, Selim; Islam, Rafikul

    2012-01-01

    Academic libraries are currently facing their greatest challenge since the explosion in tertiary education and academic publishing, which began after World War II. The global digital revolution is affecting both the traditional forms of the creation, organisation, and dissemination of knowledge, and the world of tertiary education itself. In the…

  19. Torsional Properties of TiNi Shape Memory Alloy Tape for Rotary Actuator

    Science.gov (United States)

    Takeda, K.; Tobushi, H.; Mitsui, K.; Nishimura, Y.; Miyamoto, K.

    2012-12-01

    In order to develop novel shape memory actuators, the torsional deformation of a shape memory alloy (SMA) tape and the actuator models driven by the tape were investigated. The results obtained can be summarized as follows. In the SMA tape subjected to torsion, the martensitic transformation appears along both edges of the tape due to elongation of these elements and grows to the central part. The fatigue life in both the pulsating torsion and alternating torsion is expressed by the unified relationship of the dissipated work in each cycle. Based on an opening and closing door model and a solar-powered active blind model, the two-way rotary driving actuator with a small and simple mechanism can be developed by using torsion of the SMA tape.

  20. Working in the Virtual Stacks: The New Library and Information Science

    Science.gov (United States)

    Kane, Laura Townsend, Ed.

    2011-01-01

    Thanks in part to technology, the boundaries of library positions are dissolving. It is no longer practical to discuss the profession in terms of traditional library types, and in today's library, the relationship between librarians and technology is stronger than ever. In this informative volume, veteran author Laura Townsend Kane interviews…

  1. Does Kinesiology tape counter exercise-related impairments of balance in the elderly?

    Science.gov (United States)

    Hosp, Simona; Csapo, Robert; Heinrich, Dieter; Hasler, Michael; Nachbauer, Werner

    2018-05-01

    Maintaining balance is an essential requirement for the performance of daily tasks and sporting activities, particularly in older adults to prevent falls and associated injuries. Kinesiology tape has gained great popularity in sports and is frequently used as a tool for performance enhancement. However, there is little research investigating its influence on balance. The purpose of this study was to evaluate the effect of Kinesiology tape on dynamic balance, postural stability and knee proprioception after physical activity in healthy, older adults. Twelve physically active, healthy men aged 63-77 years performed the test on two separate days, with and without Kinesiology tape at the knee joint (prospective intervention with cross-over design). Dynamic balance during an obstacle-crossing task, postural stability in a single-leg stance test, and knee joint position sense as a measure of proprioception were examined before and after 30 min of downhill walking on a treadmill. The influences of taping condition and physical activity on all parameters were statistically tested using factorial ANOVAs. Factorial ANOVA revealed significant time × taping condition interaction effects on all performance parameters (p postural stability and knee proprioception differed between the two taping conditions. The deterioration of performance was always greater when no tape was used. This study demonstrated that physical exercise significantly deteriorated dynamic balance, postural stability and knee proprioception in older men. These effects can be attenuated through the usage of Kinesiology tape. By preventing exercise-related impairments of balance, Kinesiology tape might help reduce the risk of sports-associated falls and associated injuries. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

    Science.gov (United States)

    Costen, Robert C.

    2000-01-01

    Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

  3. A software package to process an INIS magnetic tape on the VAX computer

    International Nuclear Information System (INIS)

    Omar, A.A.; Mohamed, F.A.

    1991-01-01

    This paper presents a software package whose function is to process the magnetic tapes distributed by the Atomic Energy Agency, on the VAX computers. These tapes contain abstracts of papers in the different branches of nuclear field and is supplied from the international Nuclear Information system (INIS). Two goals are aimed from this paper. First it gives a procedure to process any foreign magnetic tape on the VAX computers. Second, it solves the problem of reading the INIS tapes on a non IBM computer and thus allowing the specialists to gain from the large amount of information contained in these tapes. 11 fig

  4. Texture gradients in Fe-sheathed ex situ produced MgB2 tapes

    International Nuclear Information System (INIS)

    Lezza, P; Gladyshevskii, R; Abaecherli, V; Fluekiger, R

    2006-01-01

    Superconducting Fe-sheathed MgB 2 monofilamentary tapes have been fabricated by the powder-in-tube technique, varying the particle size of the starting MgB 2 powder and applying either cold or hot rolling during the last deformation process. Measurements of the critical current density J c with the magnetic field applied parallel or perpendicular to the tape surface revealed a pronounced anisotropy for the cold rolled tapes, which was found to increase with increasing particle size and magnetic field strength. The microstructural origin of the J c anisotropy was confirmed by means of x-ray diffraction performed on the filaments after mechanical removal of the sheath. The local texture was studied in a series of diffraction patterns collected at different distances from the filament centre, removing each time some 25 μm of the filament thickness. In the cold rolled tapes, the average orientation of the MgB 2 grains was found to approach a preferred orientation with the crystallographic c-axis perpendicular to the tape surface, near the interface with the sheath; however, the misalignment angle increased towards the centre of the tape. In the hot rolled tapes, for which no J c anisotropy was observed, the grains were found to be approximately randomly oriented. Roughness measurements performed on the side of the Fe sheath in contact with the MgB 2 filament are in agreement with the difference in texture observed for cold and hot rolled tapes

  5. Fee-based services in sci-tech libraries

    CERN Document Server

    Mount, Ellis

    2013-01-01

    This timely and important book explores how fee-based services have developed in various types of sci-tech libraries. The authoritative contributors focus on the current changing financial aspects of the sci-tech library operation and clarify for the reader how these changes have brought about conditions in which traditional methods of funding are no longer adequate. What new options are open and how they are best being applied in today's sci-tech libraries is fully and clearly explained and illustrated. Topics explored include cost allocation and cost recovery, fees for computer searching, an

  6. Tape cast isotropic, fine-grained tungsten for thermo-cyclic loading applications

    Energy Technology Data Exchange (ETDEWEB)

    Sommerer, Mathias, E-mail: Mathias.Sommerer@tum.de [Lehrstuhl für Werkstoffkunde und Werkstoffmechanik, Technische Universität München, Boltzmannstr. 15, 85748 Garching (Germany); Li, Muyuan [Max-Planck-Institut für Plasma Physik, Boltzmannstraße 2, 85748 Garching (Germany); Werner, Ewald [Lehrstuhl für Werkstoffkunde und Werkstoffmechanik, Technische Universität München, Boltzmannstr. 15, 85748 Garching (Germany); Dewitz, Hubertus von; Walter, Steffen; Lampenscherf, Stefan [Siemens AG, Corporate Technology, Otto-Hahn-Ring 6, 81730 München (Germany); Arnold, Thomas [Siemens Healthcare GmbH, Henkestr. 127, 91052 Erlangen (Germany)

    2016-04-15

    Highlights: • The tape casting process for tungsten is described. • A set-up of a HHF test facility for standing anodes is presented. • The thermo-cyclic behavior of tape cast tungsten and a reference is investigated. • The evolution of crack patterns is described in dependency of HHF-loadings. • The surface roughness of X-ray anodes is related to the microstructural evolution. - Abstract: This paper introduces tape casting as a new route for the production of isotropic and fine-grained tungsten components. Microstructural and thermal properties of tape cast tungsten samples are determined. Thermal shock behavior according to the thermo-cyclic loading of standing X-ray anodes is investigated and compared to the behavior of a rolled tungsten grade. The development of surface roughness during the thermal shock loading is discussed in relation to the development of the grain structure and crack pattern. The fine-grained and stable microstructure of the tape cast material exhibits less roughening under such test conditions.

  7. New developments for the investigation of hard X-rays emitted by peeling adhesive tapes.

    Science.gov (United States)

    Krämer, D; Lützenkirchen-Hecht, D; Lühmann, B; Keite-Telgenbüscher, K; Frahm, R

    2013-05-01

    We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet.

  8. Tags Help Make Libraries Del.icio.us: Social Bookmarking and Tagging Boost Participation

    Science.gov (United States)

    Rethlefsen, Melissa L.

    2007-01-01

    Traditional library web products, whether online public access catalogs, library databases, or even library web sites, have long been rigidly controlled and difficult to use. Patrons regularly prefer Google's simple interface. Now social bookmarking and tagging tools help librarians bridge the gap between the library's need to offer authoritative,…

  9. Online Workplace Training in Libraries

    Directory of Open Access Journals (Sweden)

    Connie K. Haley

    2008-03-01

    Full Text Available This study was designed to explore and describe the relationships between preference for online training and traditional face-to-face training. Included were variables of race, gender, age, education, experience of library employees, training providers, training locations, and institutional professional development policies, etc. in the library context. The author used a bivariate test, KruskalWallis test and Mann-Whitney U test to examine the relationship between preference for online training and related variables.

  10. Modelling of Tape Casting for Ceramic Applications

    DEFF Research Database (Denmark)

    Jabbari, Masoud

    was increased by improving the steady state model with a quasi-steady state analytical model. In order to control the most important process parameter, tape thickness, the two-doctor blade configuration was also modeled analytically. The model was developed to control the tape thickness based on the machine...... for magnetic refrigeration applications. Numerical models were developed to track the migration of the particles inside the ceramic slurry. The results showed the presence of some areas inside the ceramic in which the concentration of the particles is higher compared to other parts, creating the resulting...

  11. Transaction aware tape-infrastructure monitoring

    International Nuclear Information System (INIS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-01-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  12. Modelling and measurement of ac loss in BSCCO/Ag-tape windings

    International Nuclear Information System (INIS)

    Oomen, M P; Nanke, R; Leghissa, M

    2003-01-01

    High-temperature superconducting (HTS) transformers promise decreased weight and volume and higher efficiency. A 1 MVA HTS railway transformer was built and tested at Siemens AG. This paper deals with the prediction of ac loss in the BSCCO/Ag-tape windings. In a railway transformer the tape carries ac current in alternating field, the temperature differs from 77 K, tapes are stacked or cabled and overcurrents and higher harmonics occur. In ac-loss literature these issues are treated separately, if at all. We have developed a model that predicts the ac loss in sets of BSCCO/Ag-tape coils, and deals with the above-mentioned issues. The effect of higher harmonics on the loss in HTS tapes is considered for the first time. The paper gives a complete overview of the model equations and required input parameters. The model is validated over a wide range of the input parameters, using the measured critical current and ac loss of single tapes, single coils and sets of coils in the 1 MVA transformer. An accuracy of around 25% is achieved in all relevant cases. Presently the model is developed further, in order to describe other HTS materials and other types of applications

  13. Degradation characteristics of 2G HTS tapes with respect to an electrical breakdown

    International Nuclear Information System (INIS)

    Kang, Jong O; Lee, On You; Mo, Young Kyu; Kim, Jun Il; Bang, Seung Min; Lee, Hong Seok; Kang, Hyoung Ku; Lee, Jae Hun; Jang, Cheol Yeong

    2015-01-01

    The electrical insulation design for a superconducting coil system is important for developing high voltage superconducting apparatuses. Also, the degraded characteristics of superconducting tapes due to an electrical breakdown should be considered for superconducting coils design. In this study, the degradation characteristics of 2G high temperature superconducting (HTS) tapes were studied with respect to electrical breakdown tests. The degradation tests of 2G HTS tapes were performed with various stabilizer materials. The degradation characteristics of 2G HTS tapes such as critical current(Ic) and index number were observed by performing electrical breakdown tests. It was found that the characteristics such as Ic and index number can be degraded by an electrical breakdown. Moreover, it was concluded that the degradation characteristics of 2G HTS tapes were affected by a stabilizer material and applied breakdown voltage. The cross sectional view of 2G HTS tapes was observed by using a scanning electron microscope (SEM). As results, it is found that the degradation characteristics of 2G HTS tapes are concerned with hardness and electrical resistivity of stabilizer layers

  14. Electrical and mechanical properties of Bi-2223/Ag/barrier/Ag composite tapes

    International Nuclear Information System (INIS)

    Kovac, P.; Husek, I.; Goemoery, F.; Oduleye, O.O.; Alford, N.McN.; Pachla, W.; Diduszko, R.

    2000-01-01

    Bi-2223/Ag/barrier/Ag single-core tapes with various oxide barrier materials (BaZrO 3 , SrCO 3 , ZrO 2 and Al 2 O 3 ) have been prepared by PIT. The I-V curves and ac susceptibility measurements have been performed for tapes with identical heat treatment history. Young's moduli of these tape samples have been evaluated by three-point bending and the structure of barrier powders and BSCCO cores was analysed by SEM and XRD, respectively. It was found that the shape of I-V curves, the current transfer lengths and the mechanical properties of tapes are all affected by the oxide barrier type and the barrier thickness, as well as by its porosity and uniformity. This is because the oxide barrier controls the oxygen diffusion during the tape heat treatment and simultaneously the HTS phase formation kinetics, its purity and content within the superconducting core. On the base of the results obtained for single-core tapes, two kinds of multifilamentary composite were made and tested. (author)

  15. Library associations and social responsibilities: the cases of ALA ...

    African Journals Online (AJOL)

    Library associations should not only promote traditional library activities such as the promotion of reading and literacy, but also serve as progressive forces for change. They can serve to protect and enhance civil liberties and freedom of expression, and can promote community organization for enhancing the quality of life.

  16. Tape measure to aid prescription in paediatric resuscitation.

    OpenAIRE

    Hughes, G; Spoudeas, H; Kovar, I Z; Millington, H T

    1990-01-01

    A tape measure, based on 50th centile weight for height and designed to permit easy drug dosage calculation, endotracheal tube size and DC cardioversion current dosages in childrens' emergencies, was tested for reliability by medical and nursing staff with varying paediatric experience. We found that the tape measure gave a reproducible estimate of weight and suggest that its use would facilitate decision making by inexperienced medical and nursing staff in paediatric resuscitation when there...

  17. Research on resistance characteristics of YBCO tape under short-time DC large current impact

    Science.gov (United States)

    Zhang, Zhifeng; Yang, Jiabin; Qiu, Qingquan; Zhang, Guomin; Lin, Liangzhen

    2017-06-01

    Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance - temperature change rule and the maximum impact current. The influence of insulation for the resistance - temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.

  18. FENDL/C-1.0. Charged-particle reaction data library for fusion applications Version 1.0 of November 1991. Summary documentation

    International Nuclear Information System (INIS)

    Pashchenko, A.B.

    1995-01-01

    This document describes the FENDL/C-1.0 charged-particle reaction data library which is a sublibrary of FENDL, the evaluated nuclear data library for fusion applications. This file contains evaluated data in ENDF-6 format for the D(d,n), D(d,p), T(d,n), T(t,2n), He-3(d,p) reactions. The processed information, i.e. Maxwellian-averaged reaction rates, and related quantities, calculated from reaction cross-sections, are also included. The data are available from the Nuclear Data Section online via INTERNET by FTP command, or on magnetic tape upon request. (author). 1 tab

  19. Multilayer tape cast SOFC – Effect of anode sintering temperature

    DEFF Research Database (Denmark)

    Hauch, Anne; Birkl, Christoph; Brodersen, Karen

    2012-01-01

    Multilayer tape casting (MTC) is considered a promising, cost-efficient, up-scalable shaping process for production of planar anode supported solid oxide fuel cells (SOFC). Multilayer tape casting of the three layers comprising the half cell (anode support/active anode/electrolyte) can potentially...

  20. Information-seeking behavior of basic science researchers: implications for library services.

    Science.gov (United States)

    Haines, Laura L; Light, Jeanene; O'Malley, Donna; Delwiche, Frances A

    2010-01-01

    This study examined the information-seeking behaviors of basic science researchers to inform the development of customized library services. A qualitative study using semi-structured interviews was conducted on a sample of basic science researchers employed at a university medical school. The basic science researchers used a variety of information resources ranging from popular Internet search engines to highly technical databases. They generally relied on basic keyword searching, using the simplest interface of a database or search engine. They were highly collegial, interacting primarily with coworkers in their laboratories and colleagues employed at other institutions. They made little use of traditional library services and instead performed many traditional library functions internally. Although the basic science researchers expressed a positive attitude toward the library, they did not view its resources or services as integral to their work. To maximize their use by researchers, library resources must be accessible via departmental websites. Use of library services may be increased by cultivating relationships with key departmental administrative personnel. Despite their self-sufficiency, subjects expressed a desire for centralized information about ongoing research on campus and shared resources, suggesting a role for the library in creating and managing an institutional repository.

  1. ICI optical data storage tape: An archival mass storage media

    Science.gov (United States)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  2. Forensic Pollen Evidence from Clothes by the Tape Adhesive Method

    Directory of Open Access Journals (Sweden)

    Chun-Liang Wu

    2006-06-01

    Full Text Available Collection and identification of pollen is becoming important in forensic applications. Many criminal cases have been reported to link suspects to the crime scene by analysis of pollen. Several methods have been used in the pollen collection and analysis, but they are expensive and tedious. Therefore, it is important to develop a simple method to collect pollen grains from clothes. We tried to recover pollen from clothing surface by using the sticky tapes method. The tape adhesive method has been widely used for sample collection for various purposes, but the efficiency of recovery of invisible pollen from clothes has rarely been reported. Therefore, to test the efficiency of the tape adhesive method in recovering pollen from clothes is important. The first author wore clothes that were made from textile S made by the mixture of cotton 60% and polyester fiber 40% to collect pollen from 26 different areas mostly in the northern part of Taiwan and then used cellophane tape D (Sirchie Finger Print Lab., Inc-No. 131LT4 to recover them from different body parts. Twenty-six pollen taxa were detected in different parts of clothes depending upon what kind of plant the first author stayed near. From the results, we concluded that the tape adhesive method is suitable in recovering pollen from clothes. We have suggested that the tape adhesive method could be part of methods for collecting pollen from clothes of suspects. It is simpler, faster and less expensive than other methods.

  3. Fabrication of high edge-definition steel-tape gratings for optical encoders

    Science.gov (United States)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  4. Structural properties of superconducting Bi-2223/Ag tapes

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalck Andersen, L.

    2001-05-01

    The structural properties of silver clad high-T{sub c} superconducting ceramic tapes of (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub x} (Bi-2223) have been investigated by means of synchrotron X-ray diffraction (including the 3DXRD microscope setup), transmission electron microscopy (TEM) and scanning electron microscopy (SEM) with energy dispersive X-ray analysis (EDS). By synchrotron X-ray diffraction in situ studies of the phase development during the transformation of (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 1}Cu{sub 2}O{sub x} (Bi-2212) into Bi-2223, the stoichiometry changes and the texture have been performed during annealing in 8% O{sub 2} and in air. Furthermore, an annealing with two high temperature cycles has been performed to study the equilibrium phenomena. During heating (Ca,Sr){sub 2}PbO{sub 4} decomposes at temperatures between 700 deg. C and 840 deg.C. Simultaneously, the Bi-2212 lattice contracts, indicating an incorporation of Pb. Moreover, the grain mis-alignment decreases significantly. In air we have observed that Bi-2212 partly dissociates into (Ca,Sr){sub 2}CuO{sub 3} and a liquid at temperatures above 812 deg. C. At the annealing temperature Bi-2212 and (Ca,Sr){sub 2}CuO{sub 3} react with the liquid to form Bi-2223. The transformation mechanism is discussed. During cooling below {approx}750 deg.C (Ca,Sr){sub 2}CuO{sub 3} and the liquid mainly transform into Bi-2201. Below {approx}780 deg. C Bi-2223 decomposes to 3221. In addition, a two-step cooling experiment and a decomposition study have been performed in 8% O{sub 2}. By TEM the grain and colony size in the c-axis direction, the angles of c-axis tilt grain boundaries and the intergrowth content are investigated. A fully processed tape has on average 50% thicker grains than a tape after the 1st annealing. The angles of c-axis tilt grain boundaries are on average 14 deg. and 26 deg. for the fully processed tape and the tape after the 1st annealing, respectively. The intergrowth content (15%) and

  5. MATH77 - A LIBRARY OF MATHEMATICAL SUBPROGRAMS FOR FORTRAN 77, RELEASE 4.0

    Science.gov (United States)

    Lawson, C. L.

    1994-01-01

    OS, a Hewlett-Packard 720 computer running HP-UX, a Macintosh computer running MacOS, and an IBM PC compatible computer running MS-DOS. Accompanying the library is a set of 196 "demo" drivers that exercise all of the user-callable subprograms. The FORTRAN source code for MATH77 comprises 109K lines of code in 375 files with a total size of 4.5Mb. The demo drivers comprise 11K lines of code and 418K. Forty-four percent of the lines of the library code and 29% of those in the demo code are comment lines. The standard distribution medium for MATH77 is a .25 inch streaming magnetic tape cartridge in UNIX tar format. It is also available on a 9track 1600 BPI magnetic tape in VAX BACKUP format and a TK50 tape cartridge in VAX BACKUP format. An electronic copy of the documentation is included on the distribution media. Previous releases of MATH77 have been used over a number of years in a variety of JPL applications. MATH77 Release 4.0 was completed in 1992. MATH77 is a copyrighted work with all copyright vested in NASA.

  6. Engineering Critical Current Density Improvement in Ag- Bi-2223 Tapes

    DEFF Research Database (Denmark)

    Wang, W. G.; Seifi, Behrouz; Eriksen, Morten

    2000-01-01

    Ag alloy sheathed Bi-2223 multifilament tapes were produced by the powder-in-tube method. Engineering critical current density improvement has been achieved through both enhancement of critical current density by control of the thermal behavior of oxide powder and by an increase of the filling...... factor of the tapes. Phase evolution at initial sintering stage has been studied by a quench experiment in Ag-Bi-2223 tapes. The content, texture, and microstructure of various phases were determined by XRD and SEM. A novel process approach has been invented in which square wire was chosen rather than...

  7. Evaluated cross section libraries

    International Nuclear Information System (INIS)

    Maqurno, B.A.

    1976-01-01

    The dosimetry tape (ENDF/B-IV tape 412) was issued in a general CSEWG distribution, August 1974. The pointwise cross section data file was tested with specified reference spectra. A group averaged cross section data file (620 groups based on tape 412) was tested with the above spectra and the results are presented in this report

  8. The inhomogeneities of (Pb,Bi)2223 superconducting tapes and their detection

    International Nuclear Information System (INIS)

    Leeuwen, S. van

    1999-05-01

    This thesis consists of two parts: first, the inhomogeneities that were observed in high temperature superconducting (Pb,Bi)2223 tapes were studied followed by the design of two rigs which were built to detect them. These investigations concentrated on (Pb,Bi)2223 phase high temperature superconducting tapes. Superconductors and their applications were briefly evaluated. It was found that high temperature superconductors have unique properties which cannot be duplicated by their counterparts. However, it was noted that there are significant improvements to be made before they can be commercially viable. An investigation was carried out into the variation of core density within cross sections and along lengths of (Pb,Bi)2223 tapes during fabrication. It was observed that rolling and thermal treatment brought about a non-uniform core density in both these aspects of tile tape. This was followed by an investigation into the effect of core density on the formation of the (Pb,Bi)2223 phase. It was shown that a high core density formed the (Pb,Bi)2223 phase at a slower rate than a lower core density under the thermal treatment. A high core density and a slow heating rate produced smaller 2212 grains at the end of the incubation period. Smaller 2212 grains were thought to be linked to the faster formation of the (Pb,B1)2223 phase. The highest Jc was from a high core density tape which had the smaller 2212 grains at the end of incubation period. Smaller 2212 grains were thought to aid a more homogeneous conversion to the (Pb,Bi)2223 phase. Alloy-sheathed (Pb,Bi)2223 superconducting tapes were produced in order to fabricate a more homogeneous core density. It was found that the alloy sheath (with an addition of 15% wt Ag in the precursor powder) changed the characteristics of the core in several ways: the formation of the (Pb,Bi)2223 phase was homogeneous across the thickness of the core, a smaller 2212 grain size was formed at the end of the incubation period and a higher

  9. Ultrasound assessment of tension-free vaginal tape (TVT).

    Science.gov (United States)

    Flock, F; Kohorst, F; Kreienberg, R; Reich, A

    2011-01-01

    To date, no standardization for the visualization of tension-free vaginal tape (TVT) has been established in clinical practice. The aim of this prospective observational study was to evaluate the shape and position of the tape using ultrasound and to compare this data with clinical postoperative results. In a three-year period, 296 patients with clinically and urodynamically proven stress urinary incontinence (SUI) were treated with TVT and received follow-up in our department. An additional 12 patients, who were initially treated in other hospitals and had postoperative problems, were included in this study. Depending on the outcome after 3 months, the patients were divided into groups with and without specific disorders. The TVT was evaluated by introital ultrasound. The position of the tape was established by its location in relation to the urethral length and the distance to the hypoechoic center of the urethra (HCU). A suitable TVT position was determined in patients without any postoperative disorders. The mean value for the TVT position at rest in relation to the urethral length was 61 %. The distance to the HCU was 4.6 ± 1.5 mm. In patients with persistent SUI, the tape was more often located under the inner (3 % vs. 0 %) or outer quarter (29 % vs. 13 %, p = 0.004). In patients with residual volume, the distance to the urethra was significantly lower (2.7 vs. 4.6, p TVT may be regularly investigated using ultrasound. In combination with the clinical outcome, it represents an important method of evaluating the tape and assists in the planning of a future therapeutic course of action in cases of postoperative problems. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Marketing Today's Academic Library: A Bold New Approach to Communicating with Students

    Science.gov (United States)

    Mathews, Brian

    2009-01-01

    In "Marketing Today's Academic Library", the author uses his vast experience to speak directly to the academic library practitioner about matching services with user needs. This book proposes new visions and ideas, challenging the traditional way of thinking and providing a framework to target users more precisely. Most library marketing intended…

  11. As Libraries Go Digital, Sharing of Data Is at Odds with Tradition of Privacy

    Science.gov (United States)

    Parry, Marc

    2012-01-01

    Colleges share many things on Twitter, but one topic can be risky to broach: the reading habits of library patrons. Patrons' privacy is precious to most librarians. Yet new Web services thrive on collecting and sharing the very information that has long been protected. This points to an emerging tension as libraries embrace digital services.…

  12. Comparison of self-field effects between Bi-2223/Ag tapes and pancake coils

    International Nuclear Information System (INIS)

    Alamgir, A.K.M.; Gu, C.; Han, Z.

    2005-01-01

    Knowledge on self-field behavior in HTS tape and coil becomes important for the design of HTS devices. We report on the comparative nature and influence of self-field in Bi-2223/Ag tape and pancake coils in terms of critical current and ac loss. Measured dc and ac properties of short tape and pancake coils are verified based on the self-field. It is proved that perpendicular component of self-field acting in opposite direction at the two halves of tape-width determines critical current in short tape and single-turn coil. On the other hand, perpendicular component of self-field pointed in the same direction at the two halves of tape-width determines critical current in multi-turn coils. Influence of magnitude and orientation of self-field on ac loss is also investigated for a series of pancake coils based on the measured self-field ac loss in short sample

  13. Comparison of self-field effects between Bi-2223/Ag tapes and pancake coils

    Energy Technology Data Exchange (ETDEWEB)

    Alamgir, A.K.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China)]. E-mail: alam643@yahoo.com; Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China)

    2005-08-15

    Knowledge on self-field behavior in HTS tape and coil becomes important for the design of HTS devices. We report on the comparative nature and influence of self-field in Bi-2223/Ag tape and pancake coils in terms of critical current and ac loss. Measured dc and ac properties of short tape and pancake coils are verified based on the self-field. It is proved that perpendicular component of self-field acting in opposite direction at the two halves of tape-width determines critical current in short tape and single-turn coil. On the other hand, perpendicular component of self-field pointed in the same direction at the two halves of tape-width determines critical current in multi-turn coils. Influence of magnitude and orientation of self-field on ac loss is also investigated for a series of pancake coils based on the measured self-field ac loss in short sample.

  14. Tape casting and partial melting of Bi-2212 thick films

    Energy Technology Data Exchange (ETDEWEB)

    Buhl, D.; Lang, T.; Heeb, B. [Nichtmetallische Werkstoffe, Zuerich (Switzerland)] [and others

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density of 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).

  15. Ankle Taping Does Not Impair Performance in Jump or Balance Tests

    OpenAIRE

    Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests a...

  16. Effects of low-dye taping on plantar pressure pre and post exercise: an exploratory study.

    LENUS (Irish Health Repository)

    Nolan, Damien

    2009-01-01

    BACKGROUND: Low-Dye taping is used for excessive pronation at the subtalar joint of the foot. Previous research has focused on the tape\\'s immediate effect on plantar pressure. Its effectiveness following exercise has not been investigated. Peak plantar pressure distribution provides an indirect representation of subtalar joint kinematics. The objectives of the study were 1) To determine the effects of Low-Dye taping on peak plantar pressure immediately post-application. 2) To determine whether any initial effects are maintained following exercise. METHODS: 12 asymptomatic subjects participated; each being screened for excessive pronation (navicular drop > 10 mm). Plantar pressure data was recorded, using the F-scan, at four intervals during the testing session: un-taped, baseline-taped, post-exercise session 1, and post-exercise session 2. Each exercise session consisted of a 10-minute walk at a normal pace. The foot was divided into 6 regions during data analysis. Repeated-measures analysis of variance (ANOVA) was used to assess regional pressure variations across the four testing conditions. RESULTS: Reduced lateral forefoot peak plantar pressure was the only significant difference immediately post tape application (p = 0.039). This effect was lost after 10 minutes of exercise (p = 0.036). Each exercise session resulted in significantly higher medial forefoot peak pressure compared to un-taped; (p = 0.015) and (p = 0.014) respectively, and baseline-taped; (p = 0.036) and (p = 0.015) respectively. Medial and lateral rearfoot values had also increased after the second session (p = 0.004), following their non-significant reduction at baseline-taped. A trend towards a medial-to-lateral shift in pressure present in the midfoot immediately following tape application was still present after 20 minutes of exercise. CONCLUSION: Low-Dye tape\\'s initial effect of reduced lateral forefoot peak plantar pressure was lost after a 10-minute walk. However, the tape continued

  17. Effect of the Kinesio tape to muscle activity and vertical jump performance in healthy inactive people

    Directory of Open Access Journals (Sweden)

    Lu Szu-Ching

    2011-08-01

    Full Text Available Abstract Background Elastic taping applied on the triceps surae has been commonly used to improve the performance of lower extremities. However, little objective evidence has been documented. The purpose of this study was to investigate the effect of elastic taping on the triceps surae during a maximal vertical jump. It was hypothesized that elastic taping to the triceps surae would increase muscle activity and cause positive effect to jump height. Methods Thirty-one healthy adults (19 males and 12 females with mean age, body weight and height for 25.3 ± 3.8 years old, 64.1 ± 6.2 kg, and 169.4 ± 7.3 cm, respectively were recruited. All participants performed vertical jump tests prior to (without taping and during elastic taping. Two elastic tapes, Kinesio tape and Mplacebo tape from two different manufacturers, were applied to the participants, respectively. Results The results showed that the vertical ground reaction force increased when Kinesio tape was applied even when the height of jump remained about constant. However, the height of the jump decreased, and there was no difference on the vertical ground reaction force in Mplacebo taping group. Although the EMG activity of medial gastrocnemius tended to increase in Kinesio taping group, we did not see differences in EMG activity for the medial gastrocnemius, tibialis anterior and soleus muscles in either group. Conclusions Based on the varied effects of Kinesio tape and Mplacebo tape, different intervention technique was suggested for specific purpose during vertical jump movement. Mplacebo tape was demanded for the benefits of stabilization, protection, and the restriction of motion at the ankle joint. On the other hand, the findings may implicate benefits for medial gastrocnemius muscle strength and push-off force when using Kinesio tape.

  18. Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

    Science.gov (United States)

    Prien-Larsen, Jens Christian; Prien-Larsen, Thomas; Cieslak, Lars; Dessau, Ram B

    2016-07-01

    Although there is clear consensus on the use of monofilament polypropylene tapes for treating stress urinary incontinence (SUI), tapes differ in weight, stiffness, and elasticity. In this study, we compared outcomes of two tape types: high-stiffness Intramesh SOFT L.I.F.T versus low-stiffness Intramesh L.I.F.T. tape. Our null hypothesis was that in terms of performance, SOFT tape equaled L.I.F.T. tape. Six hundred and sixty women underwent prospective transvaginal tape (TVT) surgery for SUI: 210 had the SOFT tape placed and 450 the L.I.F.T. tape. Follow-ups were scheduled at 3 and 12 months. Objective cure at 3-months' follow-up was 87 % in the SOFT group vs 94 % in the L.I.F.T. group (p = 0.003) and at 12 months 86 vs 96 % (p = 0.0004), respectively. Subjective outcomes were equal. For SOFT tape, the objective failure rate at 3 months was especially pronounced in women older than 70 years: 31 vs 10 % (p = 0.008), and subjective failure was 24 vs 7 % (p = 0.01). At 12 months, objective failure for the SOFT tape was significantly higher in both age groups compared with L.I.F.T. [odds ratio (OR) 2.17]. Multivariate analysis showed that body mass index (BMI) ≥30 (OR 2.41), mixed incontinence (MUI) (OR 2.24), use of SOFT tape (OR 2.17), and age ≥ 70 years are significant independent risk factors for surgical failure. Outcomes with SOFT tape are significantly inferior than with L.I.F.T. tape, especially among elderly women. Therefore, the two variants of monofilament polypropylene tape are not interchangeable.

  19. Web metrics for library and information professionals

    CERN Document Server

    Stuart, David

    2014-01-01

    This is a practical guide to using web metrics to measure impact and demonstrate value. The web provides an opportunity to collect a host of different metrics, from those associated with social media accounts and websites to more traditional research outputs. This book is a clear guide for library and information professionals as to what web metrics are available and how to assess and use them to make informed decisions and demonstrate value. As individuals and organizations increasingly use the web in addition to traditional publishing avenues and formats, this book provides the tools to unlock web metrics and evaluate the impact of this content. The key topics covered include: bibliometrics, webometrics and web metrics; data collection tools; evaluating impact on the web; evaluating social media impact; investigating relationships between actors; exploring traditional publications in a new environment; web metrics and the web of data; the future of web metrics and the library and information professional.Th...

  20. Potentials of fee-based library services in Nigeria: with a case report ...

    African Journals Online (AJOL)

    Libraries have traditionally been custodians of information which are provided free of charge to users. Recent decline in funds to libraries and the change in the concept of information from a free resource to a marketable resource in the information age have necessitated the re-evaluation of free services in the libraries.

  1. Identification and quantification of glue-like off-odors in elastic therapeutic tapes.

    Science.gov (United States)

    Denk, Philipp; Buettner, Andrea

    2018-05-01

    Elastic therapeutic tapes are an important tool in the field of physical therapy and medicine. These tapes contain types of adhesive. However, sensory evaluations revealed the release of pronounced and irritating odors of the tapes. Negative odors were, amongst others, reported in elastic therapeutic tapes containing acrylic adhesives. In this study, the odor of four different tape samples was evaluated applying a descriptive analysis approach carried out by a trained sensory panel. Afterwards, the volatile compounds were recovered from the samples by solvent extraction and isolated by solvent-assisted flavor evaporation (SAFE). The obtained distillates were subsequently analyzed by gas chromatography-olfactometry (GC-O) and two-dimensional GC-O coupled with mass spectrometry (2D-GC-MS/O). To determine the most potent odorants in the distillates, odor extract dilution analyses (OEDA) were carried out. Thirty-one odorants were successfully identified using this approach, which were all described for the first time as odorants in tapes. Amongst the set of volatiles, unsaturated and saturated aldehydes were present, eliciting fatty, soapy, and citrus-like odor impressions, as well as a range of glue-like, moldy, and fruity smelling odor-active volatiles, such as 2-ethyl-1-hexanol, butyl benzoate, and 3-phenyltoluene. Based on their relative intensities, the concentrations of the glue-like smelling substances were determined: 2-ethyl-1-hexanol, present in all samples, was determined with concentrations ranging from 10 to 200 mg/kg in the investigated tapes.

  2. Device for stretching tapes or cables intended for manipulators

    International Nuclear Information System (INIS)

    Baudoin, J.-C.; Oger, Robert.

    1975-01-01

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device [fr

  3. Device for stretching tapes or cables intended for manipulators

    Energy Technology Data Exchange (ETDEWEB)

    Baudoin, J C; Oger, R

    1975-03-06

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device.

  4. An Invisible Wall: The Relationship Between Congregational and Seminary Libraries in the United States

    Directory of Open Access Journals (Sweden)

    Rebecca Klemme Eliceiri

    2013-12-01

    Full Text Available Theological (seminary and congregational libraries in the Christian and Jewish religious traditions have coexisted in some fashion since their beginnings; however, little research exists regarding the relationship between these related-but-distinct library types. This essay explores the relationship between these types of libraries through a survey of their literatures and available statistics, considering their histories and contexts within the broader religious and library worlds, as well as their current relationship in light of their diverse religious institutions. The roles of these libraries will be examined regarding religious, theological, and information literacies as well as exploring their staffs, their staff's education, funding, library hours, their goals, objectives, and outcomes, particularly regarding the changing landscape of religious and theological education for both clergy and laypeople.  It concludes with future possibilities in the religious library world in a congregational landscape that often cannot afford full-time, traditionally-theologically-educated clergy, much less paid congregational librarians.

  5. Marketing of library services in Europe

    Directory of Open Access Journals (Sweden)

    Ionel Enache

    2007-01-01

    Full Text Available This paper, based on a few articles written by specialists from different European countries, contains an objective analysis of the way the marketing techniques and instruments are implemented in libraries. In Europe, we can see that library marketing is present in different forms; in some countries it is more intense and in others it is less strong. We will surprisingly discover manifestations of marketing in unexpected places, in less developed countries, with few financial possibilities but opened to this domain and oriented towards the users, and in more developed but traditional countries, marketing techniques are in an incipient phase. Unfortunately, libraries are a long way ahead from this perspective.

  6. Ring shaped laser for tape winding of an endless tube

    NARCIS (Netherlands)

    Leonardus, Lucky

    2012-01-01

    AFPT is a start-up company that provides laser-assisted technology for the production of a pressurized component such as tube, pressure vessel, etc made from or strengthened by fiber reinforced plastic (FRP) tape. The tape is laid precisely by a machine head (connected to a robot), melted with a

  7. Age-of-Air, Tape Recorder, and Vertical Transport Schemes

    Science.gov (United States)

    Lin, S.-J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A numerical-analytic investigation of the impacts of vertical transport schemes on the model simulated age-of-air and the so-called 'tape recorder' will be presented using an idealized 1-D column transport model as well as a more realistic 3-D dynamical model. By comparing to the 'exact' solutions of 'age-of-air' and the 'tape recorder' obtainable in the 1-D setting, useful insight is gained on the impacts of numerical diffusion and dispersion of numerical schemes used in global models. Advantages and disadvantages of Eulerian, semi-Lagrangian, and Lagrangian transport schemes will be discussed. Vertical resolution requirement for numerical schemes as well as observing systems for capturing the fine details of the 'tape recorder' or any upward propagating wave-like structures can potentially be derived from the 1-D analytic model.

  8. Managing ebook metadata in academic libraries taming the tiger

    CERN Document Server

    Frederick, Donna E

    2016-01-01

    Managing ebook Metadata in Academic Libraries: Taming the Tiger tackles the topic of ebooks in academic libraries, a trend that has been welcomed by students, faculty, researchers, and library staff. However, at the same time, the reality of acquiring ebooks, making them discoverable, and managing them presents library staff with many new challenges. Traditional methods of cataloging and managing library resources are no longer relevant where the purchasing of ebooks in packages and demand driven acquisitions are the predominant models for acquiring new content. Most academic libraries have a complex metadata environment wherein multiple systems draw upon the same metadata for different purposes. This complexity makes the need for standards-based interoperable metadata more important than ever. In addition to complexity, the nature of the metadata environment itself typically varies slightly from library to library making it difficult to recommend a single set of practices and procedures which would be releva...

  9. Pinning Mechanisms in YBCO Tapes

    CERN Document Server

    Spera, Marcello; Ballarino, Amalia

    2015-01-01

    In this thesis work, a study on flux pinning mechanisms of commercial YBCO tapes is presented. This study has been performed via critical current characterization using transport (via direct I-V curves) and magnetization (via a Vibrating Sample Magnetometer) measurements. The latter ones turned out to be better concerning the comprehension of the pinning landscape of the provided samples, as a wider range of magnetic fields and temperatures is available for those measurements in the setup I used. The comparison of the experimental data with existing theoretical models allowed me to draw a picture of the pinning mechanisms underlying in each sample, and they turned out to be quite different one another. Moreover, for high-performance research tapes, another interesting feature has been found: the counterplay between the self-field critical current and the in-field one. Very well engineered artificial pinning structures limit the self-field critical current density due to the hi...

  10. Continuous welding of unidirectional fiber reinforced thermoplastic tape material

    Science.gov (United States)

    Schledjewski, Ralf

    2017-10-01

    Continuous welding techniques like thermoplastic tape placement with in situ consolidation offer several advantages over traditional manufacturing processes like autoclave consolidation, thermoforming, etc. However, still there is a need to solve several important processing issues before it becomes a viable economic process. Intensive process analysis and optimization has been carried out in the past through experimental investigation, model definition and simulation development. Today process simulation is capable to predict resulting consolidation quality. Effects of material imperfections or process parameter variations are well known. But using this knowledge to control the process based on online process monitoring and according adaption of the process parameters is still challenging. Solving inverse problems and using methods for automated code generation allowing fast implementation of algorithms on targets are required. The paper explains the placement technique in general. Process-material-property-relationships and typical material imperfections are described. Furthermore, online monitoring techniques and how to use them for a model based process control system are presented.

  11. Tape functionality: position, change in shape, and outcome after TVT procedure--mid-term results.

    Science.gov (United States)

    Kociszewski, Jacek; Rautenberg, Oliver; Kolben, Sebastian; Eberhard, Jakob; Hilgers, Reinhard; Viereck, Volker

    2010-07-01

    This study evaluates the relevance of the tape position and change in shape (tape functionality) under in vivo conditions for mid-term outcome. Changes in the sonographic tension-free vaginal tape (TVT) position relative to the percentage urethral length and the tape-urethra distance were determined after 6 and 48 months in 41 women with stress urinary incontinence. At 48 months, 76% (31/41) of women were cured, 17% (7/41) were improved, and 7% (3/41) were failures. Disturbed bladder voiding was present in 12% (5/41), de novo urge incontinence in 7% (3/41). The median TVT position was at 63% of urethral length. Median tape-urethra distance was 2.7 mm, ranging from 2.9 mm in continent patients without complications to 1.1 mm in those with obstructive complications. Patients with postoperative urine loss had a median distance of 3.9 mm. The tape was stretched at rest and C-shaped during straining in 15 of 41 women (37%) at 48 months (all continent). Patients with this tape functionality at 6 months were also cured at 48 months in 86% of cases (19/22), and only 14% (3/22) showed recurrent incontinence. Mid-term data suggest an optimal outcome if the tape is positioned at least 2 mm from the urethra at the junction of the middle and distal thirds. Patients with optimal tape functionality at 6 months are likely to show mid-term therapeutic success.

  12. Optimization of the tape placement process parameters for carbon–PPS composites

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Rietman, B.; Visser, Roy; Akkerman, Remko

    2013-01-01

    The interrelation between process parameters, material properties and interlaminar bond strength is investigated for the laser assisted tape placement process. Unidirectionally carbon reinforced poly(phenylene sulfide) (PPS) tapes were welded onto carbon woven fabric reinforced PPS laminates. The

  13. Leak isolation self-repairing tape for a water storage vessel and piping against holes

    International Nuclear Information System (INIS)

    Nagaya, Kosuke; Sekiguchi, Takahiro; Chen, Zhichao; Murakami, Iwanori

    2007-01-01

    A new type taping for a water storage vessel or piping is presented, in which water leakage is isolated automatically by its self-repairing mechanism against holes. The self-repairing unit (sealant layer) is consisting of three pieces of net with polymer particles inside lattices. Polymer particles, which expand their volume with water, is used for having self-repairing forces. In ordinary tapes, water leaks along the boundary between the tape and the vessel. In order to retain the leak isolation force, this article first discusses a method for making the sealant tape, then develops a method for fixing the sealant to the vessel. The portion of water leakage can be checked on this tape, and the method of detecting the hole or crack portion of the vessel is also presented by using the tape. (author)

  14. Silica frit formulation for low temperature co-fired ceramic tapes (LTCC)

    International Nuclear Information System (INIS)

    Nor Hayati Alias; Che Seman Mahmood

    2006-01-01

    Glassifier agents or so called fluxes could function to lower down the melting temperature of a ceramic material. Two types of silica based glass frits have been formulated to undergo vitrification at temperature lower than 1000 degree C. Frit A powder is composing of 11% Sodium Carbonate, 11% Calcium Oxide,15% Plumbum Oxide and 10% MgO while Frit B is composing of 12% Boron Oxide, 5% Ceria, 11% Sodium Carbonate and 2% Magnesium Oxide as glassifier agent in Silica powder. Two different ceramic slurries were made from a-alumina powder with addition of either Frit A or Frit B and also dispersant, binder and plasticizers, followed by casting into 0.04 mm thickness alumina green tapes. The tapes were then fired at temperature 1000 degree C to burn out plastic binder system and to vitrify the glass frits. Scanning Electron Microscopy (SEM)/EDX techniques were carried out to observe the changes in microstructure of the tape due to vitrication of glass frits. Comparisons were made with alumina green tapes without any glass frit component and with Commercial LTCC DuPont 951 tape. (Author)

  15. AC losses in horizontally parallel HTS tapes for possible wireless power transfer applications

    Science.gov (United States)

    Shen, Boyang; Geng, Jianzhao; Zhang, Xiuchang; Fu, Lin; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Gawith, James; Coombs, T. A.

    2017-12-01

    This paper presents the concept of using horizontally parallel HTS tapes with AC loss study, and the investigation on possible wireless power transfer (WPT) applications. An example of three parallel HTS tapes was proposed, whose AC loss study was carried out both from experiment using electrical method; and simulation using 2D H-formulation on the FEM platform of COMSOL Multiphysics. The electromagnetic induction around the three parallel tapes was monitored using COMSOL simulation. The electromagnetic induction and AC losses generated by a conventional three turn coil was simulated as well, and then compared to the case of three parallel tapes with the same AC transport current. The analysis demonstrates that HTS parallel tapes could be potentially used into wireless power transfer systems, which could have lower total AC losses than conventional HTS coils.

  16. The Projects of Two Different Universtiy Libraries in England

    Directory of Open Access Journals (Sweden)

    Çev.: Muhittin Gürbüz

    2017-03-01

    Full Text Available To respond to the changing needs of the 21st century, libraries are changing and must continue to change. In a competitive area, libraries either have to be brave and innovative or have to demonstrate their relevance, value and impact to make their community difference. In this study, information was given about the projects of two different universtiy libraries in England. Firstly, Study Happy project of Warwick University Library was mentioned. With the project, besides the information service which is traditional task of library, by organizing various activities aimed at providing a comfortable learning area for its users. Secondly, Reads and Rights project of Bath Spa University library was expressed. The main aim of the project is to stimulate thinking and conversations about equality and diversity and at the same time about books, reading and libraries.

  17. Patient goals after tension free vaginal tape operation

    DEFF Research Database (Denmark)

    Glavind, Karin; Bjørk, Jonna; Kousgaard, Sabrina Just

    INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology and Obstetr......INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology...

  18. New concept for a compact tape transport system

    International Nuclear Information System (INIS)

    Mlekodaj, R.L.; Zganjar, E.F.; Cole, J.D.

    1980-01-01

    A new concept in tape transport systems for the collection and counting of radioactive samples from an on-line isotope separator has been developed. This new compact design was motivated by space limitations but important additional improvements over previous designs were made in cost, simplicity and vacuum quality. The system is based on a continuous loop of 6.5 millimeter wide recording tape 116 meters long with a conducting coating on one side for beam current monitoring. One small stepping motor is required for operation

  19. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    enhancement of heat transfer with twisted tape inserts as compared to plain ... studies for heat transfer and pressure drop of laminar flow in horizontal tubes ... flow in rectangular and square plain ducts and ducts with twisted-tape inserts .... presence of the insert in the pipe causes resistance to flow and increases turbulence.

  20. The Oprah Revolution: Book Clubs in Library Media Centers

    Science.gov (United States)

    Littlejohn, Carol

    2006-01-01

    When Oprah Winfrey began her successful book club in 1996, she continued a tradition that public libraries have provided for decades. Oprah placed a spotlight on reading that encouraged many women who had never read a book "to read." Book clubs sprang up in neighborhoods, bookstores, and on Web sites. Library media centers began offering book…

  1. The effect of rigid taping with tension on mechanical displacement of the skin and change in pain perception.

    Science.gov (United States)

    Chen, Shu-Mei; Lo, Sing Kai; Cook, Jill

    2018-04-01

    To investigate the effect of rigid taping that induces mechanical displacement of the skin on pain perception. Single group experiment design with repeated measures. Twenty-three active healthy volunteers (12 men and 11 women) participated in the study. All participants received three different taping procedures: no tape, taping with tension, and taping without tension. The order of three taping conditions was randomised. Skin displacement was measured during taping with tension. A pressure algometer was used to measure the level of pain perception once before taping, and again after each taping condition, in one testing session. The participants were blind to the values of their pressure pain threshold (PPT) during the experimental period. The mean±SD skin displacement in the condition of taping with tension was 2.58±0.49cm. There were significant differences in PPT between taping with tension and taping without tension (mean difference (mean diff)±standard error (SE) 36.43±4.22kPa, p=0.000) and no tape (mean diff±SE 44.31±3.13kPa, p=0.000). No significant difference in PPT between no tape and taping without tension was found (mean diff±SE 7.88±2.83kPa, p=0.067). Taping with tension increases the threshold of pressure pain perception. Therefore, stretch and compression caused by rigid taping with tension could disturb the nociceptive signal transmission and alter pain perception. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Standard Practice for Sampling for Particulate Contamination by Tape Lift

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This practice covers procedures for sampling surfaces to determine the presence of particulate contamination, 5 m and larger. The practice consists of the application of a pressure-sensitive tape to the surface followed by the removal of particulate contamination with the removal of the tape. The tape with the adhering particles is then mounted on counting slides. Counting and measuring of particles is done by standard techniques. 1.2 This practice describes the materials and equipment required to perform sampling of surfaces for particle counting and sizing. 1.3 The criteria for acceptance or rejection of a part for conformance to surface cleanliness level requirements shall be determined by the user and are not included in this practice. 1.4 This practice is for use on surfaces that are not damaged by the application of adhesive tape. The use of this practice on any surface of any material not previously tested or for which the susceptibility to damage is unknown is not recommended. In general, metal...

  3. Using Mobile Technology to Observe Student Study Behaviors and Track Library Space Usage

    Science.gov (United States)

    Thompson, Susan

    2015-01-01

    Libraries have become increasingly interested in studying the use of spaces within their buildings. Traditional methods for tracking library building use, such as gate counts, provide little information on what patrons do once they are in the library; therefore, new methods for studying space usage are being developed. Particularly promising are…

  4. Innovative collection development for e-books at the TU Delft Library

    NARCIS (Netherlands)

    Brinkman Dzwig, Z.E.

    2013-01-01

    Thanks to new technologies libraries worldwide go digital and are accessible 24/7 from remote locations. The innovation is even more visible in traditional library tasks such as collection development and acquisitions. Those tasks are undergoing rapid transformation as well. One of the reasons is

  5. Experimental Investigations of Woven Textile Tape as Strain Sensor

    Science.gov (United States)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  6. Understanding the foundation: the state of generalist search education in library schools as related to the needs of expert searchers in medical libraries.

    Science.gov (United States)

    Nicholson, Scott

    2005-01-01

    The paper explores the current state of generalist search education in library schools and considers that foundation in respect to the Medical Library Association's statement on expert searching. Syllabi from courses with significant searching components were examined from ten of the top library schools, as determined by the U.S. News & World Report rankings. Mixed methods were used, but primarily quantitative bibliometric methods were used. The educational focus in these searching components was on understanding the generalist searching resources and typical users and on performing a reflective search through application of search strategies, controlled vocabulary, and logic appropriate to the search tool. There is a growing emphasis on Web-based search tools and a movement away from traditional set-based searching and toward free-text search strategies. While a core set of authors is used in these courses, no core set of readings is used. While library schools provide a strong foundation, future medical librarians still need to take courses that introduce them to the resources, settings, and users associated with medical libraries. In addition, as more emphasis is placed on Web-based search tools and free-text searching, instructors of the specialist medical informatics courses will need to focus on teaching traditional search methods appropriate for common tools in the medical domain.

  7. Public Library Representations and Internet Appropriations

    Directory of Open Access Journals (Sweden)

    Paula Sequeiros

    2013-11-01

    Full Text Available May the changes in the representations of the public library be propitiated by readers' appropriations of the Internet? To answer this question, a theoretically-driven and empirically-based research was developed in a public library in Portugal, combining the analysis of documents uses, the ethnography of space and Internet use, of social relations developed while reading, with the analysis of representations of the public library. No clear-cut association emerged between social-demographics or user profiles, and representations, in general. No disruptive Internet "impact" was found: Internet use may contribute to reinforce traditional representations of the library, while it may also update and democratise other representations. If the library and the Internet are represented as synonymous, the former does not make sense without the latter; but an Internet widespread and intensive use conflicts with the image of an institution dedicated to high-brow culture. Changes in uses of the public library are, instead, clearly associated with new types of readers, which in their turn reflect changes in urban social composition. URN: http://nbn-resolving.de/urn:nbn:de:0114-fqs1401141

  8. Control program for punched paper tape for the PDP-8/1 computer

    International Nuclear Information System (INIS)

    German, U.

    1976-01-01

    A program was developed for the PDP-8/1 computer to control the punched paper tape supplied by the measuring instruments. Any departure from the program is detected by an optical reader which stops the tape and displays the error on an accumulator. This program which is suitable for large amounts of data punched on paper tape has been in use at the Beer-Sheva laboratories for detecting errors in the sample changing operation. (B.G.)

  9. Fabrication and properties of Ag-Bi2223 tapes with resistive barriers for filament decoupling

    International Nuclear Information System (INIS)

    Inada, Ryoji; Fukumoto, Yohei; Yasunami, Taeko; Nakamura, Yuichi; Oota, Akio; Li Chengshang; Zhang Pingxiang

    2007-01-01

    In this paper, we prepared the Bi2223 multifilamentary tapes with Ca 2 CuO 3 + Bi2212 as interfilamentary resistive barriers to suppress the electromagnetic coupling among the filaments under AC external magnetic field. The tapes with thin barrier layers of Ca 2 CuO 3 + 30 wt% Bi2212 around the filaments were prepared by using a standard powder-in-tube (PIT) method. The outside surface of monocore Ag-sheathed rods was coated by barrier materials. Then, the several coated monocore wires were stacked and packed into another Ag or Ag-Mg alloy tube. The packed tube was drawn and rolled into tape shape. The tape was subsequently sintered to form Bi2223 phase inside filaments. For the characterization of tapes, X-ray diffraction measurements were performed to investigate the phase formation inside the filaments. The uniformity of transport properties (J c ) for barrier tapes were evaluated on the order of several metre lengths and compared with the result for the tapes without barriers. Finally, AC loss characteristics under AC parallel transverse magnetic field were investigated to examine the effect of introducing the barriers on the filament decoupling

  10. Is application of Kinesio tape to treat hyperlordosis more effective on abdominal muscles or hamstrings?

    Directory of Open Access Journals (Sweden)

    Sara Abolahrari Shirazi

    2018-01-01

    Full Text Available Background: Hyperlordosis is defined as an abnormal increase in the lumbar arch of >40°. This study compared two taping techniques include abdominal muscles and hamstrings taping for the treatment of lumbar hyperlordosis. Materials and Methods: The randomized clinical trial was performed in Shiraz, Iran, during June and September 2014. Thirty women aged 20–45 years old with at least 40° lumbar lordosis participated. The women were randomized into two groups (n = 15. Abdominal muscles taping was performed for the first group, whereas the other group underwent hamstrings taping with 30% tension. Lumbar lordosis was measured before, immediately after, and 24 h after taping. The two-way repeated measures analysis of variance was used to compare the two groups for lumbar lordosis angle. Results: No significant differences were detected between the lumbar lordosis angles before and immediately after taping in the two groups (P > 0.05. However, a significant reduction was observed in lordosis angle in the abdominal group and the hamstring group 24 h after taping relative to before intervention (P < 0.01. Conclusion: Taping of the abdominal and hamstring muscles was not effective immediately, whereas it decreased lordosis after 24 h.

  11. E-book Reader Devices and Libraries

    Directory of Open Access Journals (Sweden)

    Pažur, I.

    2011-03-01

    Full Text Available Most library studies thematically related to electronic books don't consider readers of electronic books. Only in recent years librarians conduct studies in which they want to find out readers' opinions about the possibilities, advantages and disadvantages of reading using e-readers, as well as their possible application in the libraries.User studies of e-readers have shown that their opinion is generally positive, but great attachment to traditional books is still present, e-readers are still seen only as an additional tool for reading. Sony with its e-reader (the latest Reader model Daily and Reader Store online bookstore (http://ebookstore.sony.com/is the only one who cooperate with libraries and has made lending electronic books possible. Cooperation was launched in 2009th,and the New York Public Library was the first library that offered such a service.Cooperation between Sony and libraries, indicates clearly what the near future could be if other online booksellers / publishers begin to follow the model of lending e-books through the libraries over the network. However it is possible that a large online bookstores / publishers consider that the further price reduction of e-readers and electronic books will constantly increase their sales, and in that case lending e-books will be unnecessary.Are the libraries ready for this scenario?

  12. News from the Library: Digital signage: what is it?

    CERN Multimedia

    2012-01-01

    As you might know, "digital signage" is a form of electronic display that shows information, advertising and other messages in both public and private environments.   If you visited the Library lately, you probably discovered that something has changed in the way we inform library users of how our collections and services are evolving. A screen has now replaced the traditional shelf or showcase where libraries usually display new book acquisitions. This new digital showcase dynamically displays new book and ebook acquisitions in the Library, new titles available in the Bookshop, and most downloaded ebooks. The same content will be soon displayed also on the CERN digital signage network.

  13. Numerical Modeling of the Side Flow in Tape Casting of a Non-Newtonian Fluid

    DEFF Research Database (Denmark)

    Jabbari, Masoud; Hattel, Jesper Henri

    2013-01-01

    in the tape casting process is modeled numerically with ANSYS FLUENT in combination with an Ostwald-de Waele power law constitutive equation. Based on rheometer experiments, the constants in the Ostwald-de Waele power law are identified for the considered LSM material and applied in the numerical modeling......One of the most common ways used to produce multilayer ceramics (MLC) is tape casting. In this process, the dried tape thickness is of great interest to control the desired products and applications. One of the parameters that influences the final tape thickness is the side flow factor (a) which...... is mostly measured at the end of the process by a volumetric comparison of the tape which flowed outside the casting width to the tape within the casting width. This phenomenon has not been predicted theoretically yet in the literature. In this study, the flow of (La0.85Sr0.15)0.9MnO3 (LSM) slurry...

  14. Effects of functional taping compared with sham taping and minimal intervention on pain intensity and static postural control for patients with non-specific chronic low back pain: a randomised clinical trial protocol.

    Science.gov (United States)

    Jassi, F J; Del Antônio, T; Moraes, R; George, S Z; Chaves, T C

    2017-06-01

    To investigate the immediate and 1-month effects of functional taping to lumbar spine for pain intensity and postural control in patients with chronic non-specific low back pain. Randomised clinical trial. One hundred and twenty participants aged 18 to 50 years. Participants will be allocated at random to receive one of three interventions: functional star-shape taping for 7 days, sham functional taping for 7 days or minimal intervention, one session. The primary outcomes will be pain intensity and postural control. Four measurements of static posturography will be conducted: pre-intervention, immediately after application of the tape, 7 days post-intervention (after removal of the tape) and 1-month follow-up. The secondary outcomes will be low-back-pain-related disability, global perceived effect of treatment and fear avoidance beliefs. Primary and secondary outcomes will be assessed on three occasions: pre-intervention, 7 days post-intervention and at 1-month follow-up. All statistical analyses will be conducted following intention-to-treat principles, and the treatment effects will be calculated using linear mixed models. The results of this study will determine the effects of functional taping on pain intensity and postural control compared with sham taping and minimal intervention. NCT02546466. Copyright © 2016 Chartered Society of Physiotherapy. All rights reserved.

  15. Visualization of latent fingerprints beneath opaque electrical tapes by optical coherence tomography

    Science.gov (United States)

    Liu, Kangkang; Zhang, Ning; Meng, Li; Li, Zhigang; Xu, Xiaojing

    2018-03-01

    Electrical tape is found as one type of important trace evidence in crime scene. For example, it is very frequently used to insulate wires in explosive devices in many criminal cases. The fingerprints of the suspects were often left on the adhesive side of the tapes, which can provide very useful clues for the investigation and make it possible for individual identification. The most commonly used method to detect and visualize those latent fingerprints is to peel off each layer of the tapes first and then adopt the chemical methods to develop the fingerprints on the tapes. However, the peeling-off and chemical development process would degrade and contaminate the fingerprints and thus adversely affect the accuracy of identification. Optical coherence tomography (OCT) is a novel forensic imaging modality based on lowcoherence interferometry, which has the advantages of non-destruction, micrometer-level high resolution and crosssectional imaging. In this study, a fiber-based spectral-domain OCT (SD-OCT) system with {6μm resolution was employed to obtain the image of fingerprint sandwiched between two opaque electrical tapes without any pre-processing procedure like peeling-off. Three-dimensional (3D) OCT reconstruction was performed and the subsurface image was produced to visualize the latent fingerprints. The results demonstrate that OCT is a promising tool for recovering the latent fingerprints hidden beneath opaque electrical tape non-destructively and rapidly.

  16. TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

    Science.gov (United States)

    Hubka, Petr; Nanka, Ondrej; Masata, Jaromir; Martan, Alois; Svabik, Kamil

    2016-07-01

    The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.

  17. Modelling of fluid flow in tape casting of thin ceramics: Analytical approaches and numerical investigations

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Many startup products such as multilayered inductors, multilayered varistors, piezoelectrics, ceramic fuel cells and lithium ion battery...... components are dependent upon tape casting technology. One of the growing sciences in the processing of ceramics by tape casting is the use of fluid flow analysis to control and enhance the final tapes. The fluid dynamics analysis of the ceramic slurries during tape casting is an efficient mean to elucidate...... the physical parameters crucial to the process. A review of the development of the tape casting process with particular focus on modelling the material flow is presented and in this context the current status is examined and future potential discussed....

  18. PERFORMANCE CHARACTERISTICS OF PARABOLIC SOLAR COLLECTOR WATER HEATER SYSTEM FITTED WITH NAIL TWISTED TAPES ABSORBER

    Directory of Open Access Journals (Sweden)

    K. SYED JAFAR

    2017-03-01

    Full Text Available In this paper, the experimental heat transfer, friction loss and thermal performance data for water flowing through the absorber tube fitted with two different twisted tape configurations in parabolic trough collector (PTC are presented. In the present work, a relative experimental study is carried out to investigate the performance of a PTC influenced by heat transfer through fluidabsorber wall mixing mechanism. The major findings of this experiment show that heat transport enhancement in the nail twisted tape collector perform significantly better than plain twisted tapes and also show that the smallest twisted tape ratio enhances the system performance remarkably maximizing the collector efficiency. The results suggest that the twisted tape and nail twisted tape would be a better option for high thermal energy collection in laminar region of the PTC system.

  19. Thermomechanical Analysis of Shape-Memory Composite Tape Spring

    Science.gov (United States)

    Yang, H.; Wang, L. Y.

    2013-06-01

    Intelligent materials and structures have been extensively applied for satellite designs in order to minimize the mass and reduce the cost in the launch of the spacecraft. Elastic memory composites (EMCs) have the ability of high-strain packaging and shape-memory effect, but increase the parts and total weight due to the additional heating system. Shape-memory sandwich structures Li and Wang (J. Intell. Mater. Syst. Struct. 22(14), 1605-1612, 2011) can overcome such disadvantage by using the metal skin acting as the heating element. However, the high strain in the micro-buckled metal skin decreases the deployment efficiency. This paper aims to present an insight into the folding and deployment behaviors of shape-memory composite (SMC) tape springs. A thermomechanical process was analyzed, including the packaging deformation at an elevated temperature, shape frozen at the low temperature and shape recovery after reheating. The result shows that SMC tape springs can significantly decrease the strain concentration in the metal skin, as well as exhibiting excellent shape frozen and recovery behaviors. Additionally, possible failure modes of SMC tape springs were also analyzed.

  20. Particle image velocimetry measurements of 2-dimensional velocity field around twisted tape

    Energy Technology Data Exchange (ETDEWEB)

    Song, Min Seop; Park, So Hyun; Kim, Eung Soo, E-mail: kes7741@snu.ac.kr

    2016-11-01

    Highlights: • Measurements of the flow field in a pipe with twisted tape were conducted by particle image velocimetry (PIV). • A novel matching index of refraction technique utilizing 3D printing and oil mixture was adopted to make the test section transparent. • Undistorted particle images were clearly captured in the presence of twisted tape. • 2D flow field in the pipe with twisted tape revealed the characteristic two-peak velocity profile. - Abstract: Twisted tape is a passive component used to enhance heat exchange in various devices. It induces swirl flow that increases the mixing of fluid. Thus, ITER selected the twisted tape as one of the candidates for turbulence promoting in the divertor cooling. Previous study was mainly focused on the thermohydraulic performance of the twisted tape. As detailed data on the velocity field around the twisted tape was insufficient, flow visualization study was performed to provide fundamental data on velocity field. To visualize the flow in a complex structure, novel matching index of refraction technique was used with 3-D printing and mixture of anise and mineral oil. This technique enables the camera to capture undistorted particle image for velocity field measurement. Velocity fields at Reynolds number 1370–9591 for 3 different measurement plane were obtained through particle image velocimetry. The 2-dimensional averaged velocity field data were obtained from 177 pair of instantaneous velocity fields. It reveals the characteristic two-peak flow motion in axial direction. In addition, the normalized velocity profiles were converged with increase of Reynolds numbers. Finally, the uncertainty of the result data was analyzed.

  1. Methods for tape fabrication of continuous filament composite parts and articles of manufacture thereof

    Science.gov (United States)

    Weisberg, Andrew H

    2013-10-01

    A method for forming a composite structure according to one embodiment includes forming a first ply; and forming a second ply above the first ply. Forming each ply comprises: applying a bonding material to a tape, the tape comprising a fiber and a matrix, wherein the bonding material has a curing time of less than about 1 second; and adding the tape to a substrate for forming adjacent tape winds having about a constant distance therebetween. Additional systems, methods and articles of manufacture are also presented.

  2. Intermediate term evaluation of tension-free vaginal tape outcome: Patient's perspective

    International Nuclear Information System (INIS)

    Farrukh, A.; Doyle, P.M.

    2006-01-01

    Various new sling techniques for surgical treatment of female urinary stress incontinence have evolved over the last decade and several reports indicate high objective cure rates and fewer complications compared to traditional major procedures. We conducted a study to determine the subjective outcome and satisfaction from a patient's perspective, based on their own responses to a symptom-specific health related postal questionnaire after five year five years of having Tension-free vaginal tape surgery (TVT, Gynecare, UK). Data were collected from 70 women. The end-point was improvement or cure from stress incontinence and its affect on their disease related quality of life. A significant improvement in continence was reported by 80 percent of treated women. The responses also allowed these women to appreciate the difference TVT had made on their daily activities with a definite positive impact on quality of life. (author)

  3. IMMEDIATE EFFECT OF KINESIO VERSUS MCCONNELL TAPING ON PATELLOFEMORAL PAIN SYNDROME DURING FUNCTIONAL ACTIVITIES- A COMPARATIVE STUDY

    Directory of Open Access Journals (Sweden)

    Sai Kumar. N

    2015-12-01

    Full Text Available Background: Patellofemoral pain syndrome (PFPS is a condition presenting with anterior knee pain or pain behind the patella (retro-patellar pain. The purpose of the study is to find the immediate effect of Kinesio taping versus McConnell taping in patellofemoral pain syndrome subjects during functional activities- stair ascent, stair descent and squat lift. Methods: An experimental study design with three groups, 45 subjects with patellofemoral pain syndrome was randomized. 15 subjects into each Kinesiotaping group, McConnell group and Sham group. Kinesiotaping group received patellofemoral kinesio taping technique, McConnell group received McConnell taping technique and Sham group received sham taping technique. Outcome measure pain was measured using visual analogue scale during pre and post taping pain levels that were measured during three functional activities: stair ascent, stair descent and squat lift. Results: When analysed within the group using paired ‘t’ test and wilcoxon signed rank test, there is statistically significant improvement in post pain levels in KT, MT and Sham group during stair climbing, stair descent and squat lift. When compared measuring of pre and post pain levels between three groups, there is no significant change in pain level between Kinesio taping and McConnell taping as also compared to sham taping. Conclusion: The study concluded that Kinesio taping, McConnell taping and sham taping shown immediate effect on reducing pain during functional activities such as stair climbing, stair descent and squat lift with greater percentage of pain reduction was found following Kinesiotaping and McConnell taping.

  4. Synergistic reinforcement of highly oriented poly(propylene) tapes by sepiolite nanoclay

    NARCIS (Netherlands)

    Bilotti, E.; Deng, H.; Zhang, R.; Lu, D.; Bras, W.; Fischer, H.R.; Peijs, T.

    2010-01-01

    This paper reports the properties of highly oriented nanocomposite tapes based on isotactic PP and needle-like sepiolite nanoclay, obtained by a solid state drawing process. The intrinsic 1D character of sepiolite allows its exploitation in 1D objects, such as oriented polymer fibres and tapes,

  5. The Renaissance in Library Buildings

    Directory of Open Access Journals (Sweden)

    Sarah E. Thomas

    2004-05-01

    Full Text Available In the enthusiastic embrace of the digital library, with its anytime, anywhere characteristics, some people have assumed that physical libraries will become obsolete. Yet an examination of the behavior of students and faculty and of recent renovation and construction of academic and research libraries shows that brick and mortar buildings are enjoying a renaissance. Libraries have traditionally supported the housing of collections, reader services, and the staff who manage collections and provide services. These three components continue in the 21st century, but librarians, architects, and users are collaborating to produce elegant and functional designs that reflect new spatial allocations and new purposes. Modern libraries incorporate flexibility and comfort to create an environment that is welcoming and that supports a range of research and learning activities. This paper draws on examples from recent construction and reconfiguration of academic libraries in the United States to illustrate the changing scope of the physical library and the important role it plays in serving as a community hub within a university. Among the examples selected are several relating to the challenges of collection management, including the use of compact shelving and high-density storage facilities. The paper also traces the evolution of spaces from the catalog card era to the present state in which wireless access is a standard feature. Lastly, the author touches on new and expanded roles for librarians and the ways in which design advances the effectiveness of information professionals in fulfilling these new roles.

  6. The Public Library, Democracy and Rancière's Poetics of Politics

    Science.gov (United States)

    Huzar, Timothy Jozef

    2013-01-01

    Introduction: This paper applies the thought of Jacques Rancière to the concept of democracy as it is traditionally understood in library studies literature. Methods: The paper reviews a cross-section of instances of the link between democracy and the public library in library studies literature. It offers a close textual analysis of Michael…

  7. Development of Powder-in-Tube Processed Iron Pnictide Wires and Tapes

    KAUST Repository

    Ma, Yanwei

    2011-06-01

    The development of PIT fabrication process of iron pnictide superconducting wires and tapes has been reviewed. Silver was found to be the best sheath material, since no reaction layer was observed between the silver sheath and the superconducting core. The grain connectivity of iron pnictide wires and tapes has been markedly improved by employing Ag or Pb as dopants. At present, critical current densities in excess of 3750 A /cm 2 (I c = 37.5 A) at 4.2 K have been achieved in Ag-sheathed SrKFeAs wires prepared with the above techniques, which is the highest value obtained in iron-based wires and tapes so far. Moreover, Ag-sheathed Sm-1111 superconducting tapes were successfully prepared by PIT method at temperatures as low as ̃ 900 °C, instead of commonly used temperatures of ̃ 1200 °C. These results demonstrate the feasibility of producing superconducting pnictide composite wires, even grain boundary properties require much more attention. © 2010 IEEE.

  8. Open Access in China and Its Effect on Academic Libraries

    Science.gov (United States)

    Hu, Dehua; Luo, Aijing; Liu, Haixia

    2013-01-01

    OA is to become the future of academic library exchanges in China. With the government's support and promotion of OA, more and more Chinese academic libraries have been committed to participating in OA. The rapid development of OA not only has changed the model of traditional scholarly communication and brought a free communication environment of…

  9. Search features of digital libraries

    Directory of Open Access Journals (Sweden)

    Alastair G. Smith

    2000-01-01

    Full Text Available Traditional on-line search services such as Dialog, DataStar and Lexis provide a wide range of search features (boolean and proximity operators, truncation, etc. This paper discusses the use of these features for effective searching, and argues that these features are required, regardless of advances in search engine technology. The literature on on-line searching is reviewed, identifying features that searchers find desirable for effective searching. A selective survey of current digital libraries available on the Web was undertaken, identifying which search features are present. The survey indicates that current digital libraries do not implement a wide range of search features. For instance: under half of the examples included controlled vocabulary, under half had proximity searching, only one enabled browsing of term indexes, and none of the digital libraries enable searchers to refine an initial search. Suggestions are made for enhancing the search effectiveness of digital libraries, for instance by: providing a full range of search operators, enabling browsing of search terms, enhancement of records with controlled vocabulary, enabling the refining of initial searches, etc.

  10. Temporary ectropion therapy by adhesive taping: a case study

    Directory of Open Access Journals (Sweden)

    Habermann Anke

    2008-07-01

    Full Text Available Abstract Introduction Various surgical procedures are available to correct paralytic ectropion, which are applied in irreversible facial paresis. Problems occur when facial paresis has an unclear prognosis, since surgery of the lower eyelid is usually irreversible. We propose a simple method to correct temporary ectropion in facial palsy by applying an adhesive strip. Patients and methods Ten patients with peripheral facial paresis and paralytic ectropion were treated with an adhesive strip to correct paralytic ectropion. We used "Steri-Strips" (45 × 6.0 mm, which were taped on the carefully cleaned skin of the lower eyelid and of the adjacent zygomatic region until the prognosis of the paresis was clarified. In addition to the examiner's evaluation of the lower lacrimal point in the lacrimal lake, subjective improvement of the symptoms was assessed using a visual analogue scale (VAS, 1–10. Results 9 patients reported a clear improvement of the symptoms after adhesive taping. There was a clear regression of tearing (VAS (median = 8; 1 = no improvement, 10 = very good improvement, the cosmetic impairment of the adhesive tape was low (VAS (median = 2.5; 1 = no impairment, 10 = severe impairment and most of the patients found the use of the adhesive strip helpful. There was slight reddening of the skin in one case and well tolerated by the facial skin in the other cases. Conclusion The cause and location of facial nerve damage are decisive for the type of surgical therapy. In potentially reversible facial paresis, procedures should be used that are easily performed and above all reversible without complications. Until a reliable prognosis of the paresis can be made, adhesive taping is suited for the temporary treatment of paralytic ectropion. Adhesive taping is simple and can be performed by the patient.

  11. Technical and economical evaluation of tape drip and drip line irrigation systems in a strawberry greenhouse

    Directory of Open Access Journals (Sweden)

    Soghra HOSSEINIAN

    2016-04-01

    Full Text Available This study was done in a strawberry greenhouse to examine the technical and the economical evaluation of two drip irrigation systems including the tape and the drip line in the northern part of Iran. The result showed that all of the technical indices with tape were higher than drip line, and due to statistical analysis reveal a significant difference (P < 0.05. Yield and water productivity (WP with tape were higher than drip line (P < 0.05. Benefit per drop (BPD and net benefit per drop (NBPD with tape were higher than drip line. Net present value, internal rate of capital return and benefit to cost ratio in drip line were higher than tape. In general, regarding technical evaluation tape was better than drip line, besides according to the economical evaluation the drip ­lines were better than tape.

  12. Using an Untapped Resource: Expanding the Role of the Student Worker at the Bio-Medical Library

    Science.gov (United States)

    Aho, Melissa K.; Beschnett, Anne M.; Reimer, Emily Y.

    2010-01-01

    Student workers have always been a traditional and valuable component to the smooth running of many academic health sciences libraries. However, in recent years many libraries have redefined student workers' roles to extend beyond their traditional scope due to a range of factors, such as loss of staff and budget cutbacks. The Bio-Medical Library…

  13. The Ten Commandments revisited: the Qualities of Good Library Space

    Directory of Open Access Journals (Sweden)

    Andrew McDonald

    2006-06-01

    Full Text Available An increasing diversity of imaginative new academic libraries are being constructed around the world, successfully combining exciting architectural expression, inspiring internal spaces and good functionality. Library managers must have a strong vision for the new library and this should inspire the design and the whole building process. This paper explores the key qualities of good learning space, whether in new or refurbished buildings. It is suggested that, ideally, learning space should be functional, adaptable, accessible, varied, interactive, conducive, environmentally suitable, safe and secure, efficient and suitable for information technology. New space should also have “oomph”, capturing the minds of users and the spirit of the university. These indicative issues should be discussed in the brief and throughout the planning process, and the priority given to them will depend on the mission and culture of the library. Greater attention is being given to daylight, natural ventilation, cultural artwork, noise management, security, disabled access, information skills training and provision for e-services. Planning is increasingly centred on people or the learner, emphasising the need for social, interactive and collaborative learning spaces as well as for traditional spaces for quiet study and reflection. Some libraries are joined-up with other services. The academic library is an enduring physical ‘place’, providing a blended, hybrid environment of traditional and electronic services crucial for the future of our universities and their communities.

  14. Elongated grains in cube textured nickel substrate tapes and flat wires

    International Nuclear Information System (INIS)

    Eickemeyer, J; Gueth, A; Holzapfel, B

    2008-01-01

    Cube textured nickel substrate tapes and flat wires with an increased grain aspect ratio were prepared from nickel micro-alloyed with silver plus yttrium and silver, respectively. Whereas the maximum grain aspect ratio for the tapes was about 6, this value reached up to 14 for the flat wires

  15. Gender Dimension of Use of Library: The Case of Federal University ...

    African Journals Online (AJOL)

    learn. They argue that “contrary to predictions from the social role model gender differences were most pronounced in European and American cultures in which traditional sex roles are minimized. University Library as an academic Library is equipped with various information. Resources which include print and non- print.

  16. Percolation modelling for highly aligned polycrystalline superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Rutter, N A; Glowacki, B A; Evetts, J E [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); IRC in Superconductivity, Madingley Road, Cambridge CB3 0HE (United Kingdom)

    2000-11-01

    Surface and bulk texture measurements have been carried out on highly aligned NiFe tapes, suitable for use as coated conductor substrates. Data from small-area electron backscatter diffraction measurements are compared with those from bulk x-ray analysis in the development of a two-dimensional percolation model, and the two are shown to give very similar results. No evidence of grain-to-grain correlation is found. The model is then developed to assess how the properties of a superconducting layer grown epitaxially on buffered tapes will depend on parameters such as sample size, grain size and the extent of grain alignment. (author)

  17. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  18. 15th ACM/IEEE-CS Joint Conference on Digital Libraries: Large, Dynamic and Ubiquitous - The Era of the Digital Library

    CERN Document Server

    2015-01-01

    Big Data is everywhere – from Computational Science to Digital Humanities, from Web Analytics to traditional libraries. While there do exist significant challenges in other areas, for many the biggest issue of all is a digital libraries one – How do we preserve big data collections? How do we provide access to big data collections? What new questions can we pose against our big data collections? These are all digital libraries questions. How can we, the digital libraries community, stand up in the face of these challenges and inform collection builders, curators, and interface developers how to best solve their challenges? What assumptions have we been working under that no longer hold in light of Big Data? These are some of the timely questions we hope to address at JCDL 2015.

  19. Properties of hot pressed MgB2/Ti tapes

    International Nuclear Information System (INIS)

    Kovac, P.; Husek, I.; Melisek, T.; Fedor, J.; Cambel, V.; Morawski, A.; Kario, A.

    2009-01-01

    Hot axial and hot isostatic pressing was applied for single-core MgB 2 /Ti tapes. Differences in transport current density, n-exponents and critical current anisotropy are discussed and related to the grain connectivity influenced by pressing. The magnetic Hall probe scanning measurements allowed observing the isolated regions for axially hot pressed sample attributed to the longitudinally oriented cracks introduced by pressing. The highest current densities were measured for the tape subjected to hot isostatic pressing due to improved connectivity.

  20. Thermal conductivity measurement of HTS tapes and stacks for current lead applications

    International Nuclear Information System (INIS)

    Schwarz, Michael; Weiss, Klaus-Peter; Heller, Reinhard; Fietz, Walter H.

    2009-01-01

    The use of high-temperature-superconductors (HTS) within current leads offers a high potential to save cooling-power. The principle of HTS current leads is well established, e.g. for particle accelerators (LHC-CERN) but also on the commercial sector, which offer HTS current leads ready for use in small scale magnets and magnets systems. Future fusion machines currently under construction like ITER, W7-X or JT-60SA also will use HTS current leads. At the moment the standard material for HTS current leads is a Bi 2 Sr 2 Ca 2 Cu 3 O x (BSCCO)-AgAu composite tape. The common way to receive high current capacity current leads is to form stacks by sintering or soldering these tapes together. The solder changes the thermal conductivity of the stacks compared to the single tape in the temperature range from 4 K to 60 K. To estimate the heat flux from the warm environment to the cold application the measurement of the thermal conductivity of the soldered stack is mandatory. Therefore the thermal conductivity of stacks with different number of tapes is investigated. To measure the thermal conduction in the current flow direction, the axial heat flow method is used. Combining these results with FEM simulations gives the possibility to estimate the thermal conductivity normal to the flat tape plane. The resulting anisotropic thermal conductivity can be used to model the behaviour of the HTS tape under thermal disturbances more accurately.

  1. What Qualifications and Skills Are Important for Digital Librarian Positions in Academic Libraries? A Job Advertisement Analysis

    Science.gov (United States)

    Choi, Youngok; Rasmussen, Edie

    2009-01-01

    As academic library functions and activities continue to evolve, libraries have broadened the traditional library model, which focuses on management of physical resources and activities, to include a digital library model, transforming resources and services into digital formats to support teaching, learning, and research. This transition has…

  2. High rate of vaginal erosions associated with the mentor ObTape.

    Science.gov (United States)

    Yamada, Brian S; Govier, Fred E; Stefanovic, Ksenija B; Kobashi, Kathleen C

    2006-08-01

    The transobturator tape method is a newer surgical technique for the treatment of stress urinary incontinence. Limited data exist related to complications with this approach or the types of mesh products used. We report our experience with vaginal erosions associated with the Mentor ObTape and American Medical Systems Monarc transobturator slings. Beginning in December 2003 selected female patients with anatomic urinary incontinence were prospectively followed after placement of the Mentor ObTape. Beginning in January 2004 we also began using the American Medical Systems Monarc in similar patients. Patients were admitted overnight after surgery, discharged on oral antibiotics, and seen in the clinic at 6 weeks postoperatively. A total of 67 patients have undergone placement of the Mentor ObTape and 9 of those patients (13.4%) have had vaginal extrusions of the sling. Eight patients reported a history of persistent vaginal discharge. One patient presented initially to an outside facility with a left thigh abscess tracking to the left inguinal incision site. Each patient was taken back to the operating room for mesh removal. A total of 56 patients have undergone placement of the AMS Monarc and none have had any vaginal erosions. Our high rate of vaginal extrusion using the ObTape has led us to discontinue the use of this product in our institution. Continued followup of all of these patients will be of critical importance.

  3. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process

    Science.gov (United States)

    Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-01

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing. PMID:29385048

  4. Marketing Academic Libraries: A Necessary Plan.

    Science.gov (United States)

    Dodsworth, Ellen

    1998-01-01

    To coordinate an academic-library marketing effort effectively, a comprehensive plan is essential. A traditional marketing plan consists of four activities: determining what to promote, defining target audiences, choosing type of outreach, and evaluating program. Suggestions for promotional activities, forms of publicity, and examples from the…

  5. Conductive sub-layer of twisted-tape-induced swirl-flow heat transfer in vertical circular tubes with various twisted-tape inserts

    Science.gov (United States)

    Hata, K.; Fukuda, K.; Masuzaki, S.

    2018-04-01

    Twisted-tape-induced swirl-flow heat transfer due to exponentially increasing heat inputs with various exponential periods ( Q = Q 0 exp(t/τ), τ = 6.04 to 23.07 s) and twisted-tape-induced pressure drop was systematically measured for various mass velocities ( G = 4115 to 13,656 kg/m2 s), inlet liquid temperatures ( T in = 285.88 to 299.09 K), and inlet pressures ( P in = 847.45 to 943.29 kPa) using an experimental water loop flow. Measurements were made over a 59.2-mm effective length and three sections (upper, middle, and lower positions), within which four potential taps were spot-welded onto the outer surface of a 6-mm-inner-diameter, 69.6-mm-heated length, 0.4-mm-thickness platinum circular test tube. Type SUS304 twisted tapes with a width w = 5.6 mm, a thickness δ T = 0.6 mm, a total length l = 372 mm, and twist ratios y = 2.39 and 4.45 were employed in this study. The RANS equations (Reynolds Averaged Navier-Stokes Simulation) with a k-ɛ turbulence model for a circular tube 6 mm in diameter and 636 mm in length were numerically solved for heating of water with a heated section 6 mm in diameter and 70 mm in length using the CFD code, under the same conditions as the experimental ones and considering the temperature dependence of the thermo-physical properties concerned. The theoretical values of surface heat flux q on the circular tubes with twisted tapes with twist ratios y of 2.39 and 4.45 were found to be almost in agreement with the corresponding experimental values of heat flux q, with deviations of less than 30% for the range of temperature difference between the average heater inner surface temperature and the liquid bulk mean temperature ΔT L [ = T s,av - T L , T L = ( T in + T out )/2] considered in this study. The theoretical values of the local surface temperature T s , local average liquid temperature T f,av , and local liquid pressure drop ΔP x were found to be within almost 15% of the corresponding experimental ones. The thickness of the

  6. Optimal compliance for amblyopia therapy: occlusion with a translucent tape on the lens.

    Science.gov (United States)

    Beneish, Raquel G; Polomeno, Robert C; Flanders, Michael E; Koenekoop, Robert K

    2009-10-01

    To demonstrate that optimal compliance to amblyopia therapy and a better visual outcome can be achieved by occluding the lens over the preferred eye with a translucent tape. Prospective study of amblyopic children. Eighty-four amblyopic children recruited from 2000 to 2006 at the Montreal Children's Vision Centre. A group of bilateral ametropes (mean age 3.8 years) were treated with glasses and occlusion of the sound eye with a translucent tape on the lens over the preferred eye, or an adhesive patch. The translucent tape reduced vision to hand motion at 0.3 m in the sound eye. Patients were divided into 2 groups depending on the treatment received. Group 1 (n = 36) was occluded with a translucent tape, and group 2 (n = 48) with a conventional adhesive patch, later replaced by the translucent tape. Twenty-five previously reported patients, treated with the conventional adhesive patch only, were used as controls (group 3). The mean amblyopic visual acuity was 20/100-2. Compliance was good in 36 patients (group 1), and was poor or deteriorated in 24/48 patients (group 2). Substituting the adhesive patch with a translucent tape permitted uninterrupted and prolonged occlusion, with a successful visual outcome. The amblyopic eye achieved a significantly better final vision (20/30+2; groups 1+2) than the controls (20/40+1; group 3) (p = 0.04). Sixty-four (76.19%) patients achieved >or=20/30. The translucent tape optimizes compliance and yields better vision by lengthening the duration of occlusion therapy and reducing the number of treatment failures due to noncompliance.

  7. Use of nitrogen cryogun for separating duct tape and recovery of latent fingerprints with a powder suspension method.

    Science.gov (United States)

    Bailey, James A; Crane, Jonathan Stuart

    2011-07-15

    Duct tape is sometimes recovered as physical evidence in crimes. The purpose of this study was to determine the quality of latent prints on the adhesive and non-adhesive surfaces of duct tape samples that were separated using three methods. Three hundred donor fingerprint impressions were deposited on duct tape. Sections of duct tape were affixed to sections of cardboard and a fingerprint placed on the non-adhesive surface of the tape. A second layer of duct tape was prepared and a fingerprint placed on the adhesive side of the tape and then the tape was affixed to the piece of tape on the cardboard. After a 24-h period, the samples were separated using gradual force, liquid nitrogen applied with a cryogun and an adhesive neutralizer to separate the layers of tape. The recovered fingerprints were processed with a fingerprint powder suspension method. The recovered fingerprint images were evaluated and rated as +1, +2, or +3. The liquid nitrogen spray separation method yielded the highest number of +3 prints. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. "Space slitter" for film or tape

    Science.gov (United States)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  9. Digital libraries and World Wide Web sites and page persistence.

    Directory of Open Access Journals (Sweden)

    Wallace Koehler

    1999-01-01

    Full Text Available Web pages and Web sites, some argue, can either be collected as elements of digital or hybrid libraries, or, as others would have it, the WWW is itself a library. We begin with the assumption that Web pages and Web sites can be collected and categorized. The paper explores the proposition that the WWW constitutes a library. We conclude that the Web is not a digital library. However, its component parts can be aggregated and included as parts of digital library collections. These, in turn, can be incorporated into "hybrid libraries." These are libraries with both traditional and digital collections. Material on the Web can be organized and managed. Native documents can be collected in situ, disseminated, distributed, catalogueed, indexed, controlled, in traditional library fashion. The Web therefore is not a library, but material for library collections is selected from the Web. That said, the Web and its component parts are dynamic. Web documents undergo two kinds of change. The first type, the type addressed in this paper, is "persistence" or the existence or disappearance of Web pages and sites, or in a word the lifecycle of Web documents. "Intermittence" is a variant of persistence, and is defined as the disappearance but reappearance of Web documents. At any given time, about five percent of Web pages are intermittent, which is to say they are gone but will return. Over time a Web collection erodes. Based on a 120-week longitudinal study of a sample of Web documents, it appears that the half-life of a Web page is somewhat less than two years and the half-life of a Web site is somewhat more than two years. That is to say, an unweeded Web document collection created two years ago would contain the same number of URLs, but only half of those URLs point to content. The second type of change Web documents experience is change in Web page or Web site content. Again based on the Web document samples, very nearly all Web pages and sites undergo some

  10. Quantitative analysis of the effects of strain-state on the microstructure and Jc of BSCCO tapes

    International Nuclear Information System (INIS)

    Blumenthal, W.R.; Zhu, Y.T.; Sebring, R.J.; Lowe, T.C.; Asaro, R.J.

    1996-01-01

    After considerable optimization efforts, conventional thermomechanical processing of long, high temperature superconductors has not produced critical current densities (J c ) adequate for most liquid nitrogen temperature applications. New approaches are needed to improve the J c of superconducting tape produced by co-deforming a ductile silver sheath containing the superconducting oxide using the powder-in-tube process. This study investigates improvements in J c generated by modifying the strain-state during rolling of silver-sheathed Bi 2 Sr 2 Ca 2 Cu 3 O 10+x (BSCCO-2223) tape using quantitative image analysis of the different phases. Pure compression and combined compression-shear loading was achieved by embedding BSCCO-2223 tapes at different locations within thick steel blocks. High hydrostatic compressive stress was imposed by confining the tape width. Tapes deformed with combined shear-compression exhibited measurably higher J c values than tapes subjected to pure compression, but their microstructures showed little difference in the amount of nonconducting (including porosity) phase content. However, constraining the tape width resulted in the most significant increase in J c which corresponded to a much lower porosity and nonconducting phase volume in the oxide near the tape edge

  11. FENDL/D-2.0. Decay data library for fusion applications. Version 1 of June 1996. Summary documentation

    International Nuclear Information System (INIS)

    Pashchenko, A.B.; Wienke, H.

    1997-01-01

    The FENDL-2 sublibrary FENDL/D-2.0 contains decay properties (decay type, decay energy, half life) for 1867 nuclides and isomers. It is identical to the EAF-4.1 decay library and is therefore complementary to the activation cross section sublibrary FENDL/A-2.0. The data, in ENDF-6 format as well as processed into MCNP and REAC compatible formats, are available from the IAEA Nuclear Data Section online via INTERNET by FTP command, or on magnetic tape upon request. (author)

  12. Influence of bress laminate volume fraction on electromechanical properties of externally laminated coated conductor tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay M.; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Lee, Jae Hun; Lee, Hun Ju; Moon, Seung Hyun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-09-15

    The enhancement of mechanical properties of coated conductor (CC) tapes in practical application are usually achieved by reinforcing through lamination or electroplating metal layers on either sides of the CC tape. Mechanical or electromechanical properties of the CC tapes have been largely affected by the lamination structure under various loading modes such as tension, bending or even cyclic. In this study, the influence of brass laminate volume fraction on electromechanical properties of RCE-DR processed Gadolinium-barium-copper-oxide (GdBCO) CC tapes was investigated. The samples used were composed of single-side and both-side laminate of brass layer to the Cu-stabilized CC tape and their Ic behaviors were compared to those of the Cu-stabilized CC tape without external lamination. The stress/strain dependences of Ic in laminated CC tapes under uniaxial tension were analyzed and the irreversible stress/strain limits were determined. As a result, the increase of brass laminate volume fraction initially increased the irreversible strain limit and became gradual. The corresponding irreversible stress limit, however, showed no difference even though the brass laminate volume fraction increased to 3.4. But the irreversible load limit linearly increased with the brass laminate volume fraction.

  13. A new concept for a compact tape transport system

    International Nuclear Information System (INIS)

    Mlekodaj, R.L.; Zganjar, E.F.; Cole, J.D.

    1981-01-01

    A new concept in tape transport systems for the collection and counting of radioactive samples from an on-line isotope separator has been developed. This new compact design was motivated by space limitations but important additional improvements over previous designs were made in cost, simplicity and vacuum quality. The system is based on a continuous loop of 6.5 mm wide recording tape 116 m long with a conducting coating on one side for beam current monitoring. One small stepping motor is required for operation. (orig.)

  14. Current evidence does not support the use of Kinesio Taping in clinical practice: a systematic review

    Directory of Open Access Journals (Sweden)

    Patrícia do Carmo Silva Parreira

    2014-03-01

    Full Text Available Questions: Is Kinesio Taping more effective than a sham taping/placebo, no treatment or other interventions in people with musculoskeletal conditions? Is the addition of Kinesio Taping to other interventions more effective than other interventions alone in people with musculoskeletal conditions? Design: Systematic review of randomised trials. Participants: People with musculoskeletal conditions. Intervention: Kinesio Taping was compared with sham taping/placebo, no treatment, exercises, manual therapy and conventional physiotherapy. Outcome measures: Pain intensity, disability, quality of life, return to work, and global impression of recovery. Results: Twelve randomised trials involving 495 participants were included in the review. The effectiveness of the Kinesio Taping was tested in participants with: shoulder pain in two trials; knee pain in three trials; chronic low back pain in two trials; neck pain in three trials; plantar fasciitis in one trial; and multiple musculoskeletal conditions in one trial. The methodological quality of eligible trials was moderate, with a mean of 6.1 points on the 10-point PEDro Scale score. Overall, Kinesio Taping was no better than sham taping/placebo and active comparison groups. In all comparisons where Kinesio Taping was better than an active or a sham control group, the effect sizes were small and probably not clinically significant or the trials were of low quality. Conclusion: This review provides the most updated evidence on the effectiveness of the Kinesio Taping for musculoskeletal conditions. The current evidence does not support the use of this intervention in these clinical populations. PROSPERO registration: CRD42012003436. [Parreira PdCS, Costa LdCM, Hespanhol Junior LC, Lopes AD, Costa LOP (2014 Current evidence does not support the use of Kinesio Taping in clinical practice: a systematic review. Journal of Physiotherapy 60: 31–39

  15. FENDL/MG-2.0 and FENDL/MC-2.0. The processed cross-section libraries for neutron photon transport calculations. Version 1, March 1997. Summary documentation

    International Nuclear Information System (INIS)

    Wienke, H.; Herman, M.

    1998-01-01

    Evaluated neutron reaction data and photon-atom interaction cross sections for materials contained in the general purpose Fusion Evaluated Nuclear Data Library (FENDL/E2.0) have been processed with the NJOY code system into VITAMIN-J multigroup structure, for use in discrete-ordinates transport codes, and into continuous energy ACE format, for use in the Monte Carlo transport code MCNP. This document summarizes the resulting data libraries FENDL/MG-2.0 version 1 and FENDL/MC-2.0 version 1. The data are available costfree from the IAEA Nuclear Data Section online or on magnetic tape. (author)

  16. How and Why Libraries Are Changing: What We Know and What We Need To Know.

    Science.gov (United States)

    Troll, Denise A.

    2002-01-01

    Examines the importance of understanding how and why academic libraries are changing, analyzes the limitations and difficulties of traditional library performance measures, and explores environmental factors that may help account for why library use is changing. Discusses how user behavior and preferences affect demand for and use of library…

  17. FENDL/MC. Library of continuous energy cross sections in ACE format for neutron-photon transport calculations with the Monte Carlo N-particle Transport Code system MCNP 4A. Version 1.1 of March 1995. Summary documentation

    International Nuclear Information System (INIS)

    Pashchenko, A.B.; Wienke, H.; Ganesan, S.

    1996-01-01

    Selected neutron reaction nuclear data evaluations for elements of interest to the IAEA's program on Fusion Evaluated Nuclear Data Library (FENDL) have been processed into ACE format using the NJOY system by R.E. MacFarlane. This document summarizes the resulting continuous energy cross-section data library FENDL/MC version 1.1. The data are available cost free, upon request from the IAEA Nuclear Data Section, online or on magnetic tape. (author). 1 tab

  18. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    International Nuclear Information System (INIS)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan; Yang, Xinsheng; Zhao, Yong

    2015-01-01

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  19. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Yang, Xinsheng, E-mail: xsyang@swjtu.edu.cn [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Zhao, Yong [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Superconductivity Research Group, School of Materials Science and Engineering, University of New South Wale, Sydney 2052, NSW (Australia)

    2015-12-15

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  20. Libraries, Self-Censorship, and Information Technologies.

    Science.gov (United States)

    Buschman, John

    1994-01-01

    Explores the theme of self-censorship in libraries in relation to new technologies. Highlights include the results of investing in high-cost electronic resources at the expense of traditional, lower-status formats; the effect of information technologies on literacy and historical records; and market censorship, including centralization and…

  1. The Changing Purposes of University Libraries

    Science.gov (United States)

    Evans, G. R.

    2013-01-01

    This article explores recent developments in national policy for academic libraries. It considers the shift from traditional to managerial academic librarianship; the move to "social space" and multi-use systems; changes in the balance between meeting teaching and research needs and in public funding priorities; the difficulty of making…

  2. Digital library and the Slovenian academic environment

    Directory of Open Access Journals (Sweden)

    Martina Kerec

    2001-01-01

    Full Text Available Digital library is a term for a library of the present and of the future challenging the traditional libraries. Authors are interested mostly in the digital space of Slovene academic instutions. In the research, the digital collections of most of the University of Ljubljana faculties are examined. A questionnaire was used to obtain information about the users' (students' needs and their acquaintance with the concept of the digital library. Two things were expected: the research was aimed at finding the positive effect of digital libraries on studies, and the questionnaire as an incentive in the library profession for further research. The questionnaire was made in the end of 1999 at the Faculty of Arts in Ljubljana (FF. It included 275 students of FF. The results showed that the students of librarianship had a better understanding of the term digital library than the students of other courses. A personal computer is used frequently and with pleasure by most questioned students. The term digital library is known to 71,1% of the students of librarianship, and only to 43,8% of others. Most of the students chose the correct definition of the digital library (the digital library is a collection of disparate systems and resources, accessible on the net, but that was, by the authors' opinion, mostly a lucky guess. According to the findings of the research, the authors believe that future development will improve and accelerate a wider use of digital libraries, in Slovenia as well.

  3. Library and Information Science (LIS Transferable Competencies

    Directory of Open Access Journals (Sweden)

    Melissa Fraser-Arnott

    2013-09-01

    Full Text Available This article uses data obtained from a content analysis of job advertisements to explore the questions of (1 what types of non-traditional jobs are available for library and information science (LIS professionals and (2 how can LIS students and professionals take advantage of non-traditional job opportunities. Two groups of job advertisements were used in this investigation: advertisements from LIS-targeted job boards (two library school job boards and two library association job boards and Government of Canada internal job postings. These two sets of job postings were selected to compare the competencies in job postings targeted to LIS graduates (the LIS job board advertisements and job postings that were not targeted to the LIS community (the Government of Canada job advertisements. An analysis of these groups of job advertisements demonstrated that both samples focused mainly on transferable competencies. Due to the emphasis on transferable competencies, the analysis of job postings from the Government of Canada job list revealed that there are many non-traditional opportunities for LIS graduates. A typical LIS professional could apply for 51 (or 25.8% of the job advertisements in this set, having met all of the listed criteria. This individual may be able to apply for an additional 40 (or 21.2% of the jobs listed if they had certain additional competencies or knowledge obtained through prior experience working in the Government of Canada but not necessarily obtained by the average LIS professional. This supports the argument that there are numerous opportunities for LIS professionals in non-traditional jobs. The exploration of commonly requested competencies can be used to guide LIS job seekers to craft their resumes and CVs to address the competencies requested by potential employers.

  4. FENDL/E-2.0. Evaluated nuclear data library of neutron-nucleus interaction cross sections and photon production cross sections and photon-atom interaction cross sections for fusion applications. Version 1, March 1997. Summary documentation

    International Nuclear Information System (INIS)

    Pashchenko, A.B.; Wienke, H.

    1998-01-01

    This document presents the description of a physical tape containing the basic evaluated nuclear data library of neutron-nucleus interaction cross sections, photon production cross sections and photon-atom interaction cross sections for fusion applications. It is part of the evaluated nuclear data library for fusion applications FENDL-2. The data are available cost-free from the Nuclear Data Section upon request. The data can also be retrieved by the user via online access through international computer networks. (author)

  5. Laser-assisted patterning of double-sided adhesive tapes for optofluidic chip integration

    Science.gov (United States)

    Zamora, Vanessa; Janeczka, Christian; Arndt-Staufenbiel, Norbert; Havlik, George; Queisser, Marco; Schröder, Henning

    2018-02-01

    Portable high-sensitivity biosensors exhibit a growing demand in healthcare, food industry and environmental monitoring sectors. Optical biosensors based on photonic integration platforms are attractive candidates due to their high sensitivity, compactness and multiplexing capabilities. However, they need a low-cost and reliable integration with the microfluidic system. Laser-micropatterned double-sided biocompatible adhesive tapes are promising bonding layers for hybrid integration of an optofluidic biochip. As a part of the EU-PHOCNOSIS project, double-sided adhesive tapes have been proposed to integrate the polymer microfluidic system with the optical integrated waveguide sensor chip. Here the adhesive tape should be patterned in a micrometer scale in order to create an interaction between the sample that flows through the polymer microchannel and the photonic sensing microstructure. Three laser-assisted structuring methods are investigated to transfer microchannel patterns to the adhesive tape. The test structure design consists of a single channel with 400 μm wide, 30 mm length and two circular receivers with 3 mm radius. The best structuring results are found by using the picosecond UV laser where smooth and straight channel cross-sections are obtained. Such patterned tapes are used to bond blank polymer substrates to blank silicon substrates. As a proof of concept, the hybrid integration is tested using colored DI-water. Structuring tests related to the reduction of channel widths are also considered in this work. The use of this technique enables a simple and rapid manufacturing of narrow channels (50-60 μm in width) in adhesive tapes, achieving a cheap and stable integration of the optofluidic biochip.

  6. Comparison of Broselow tape measurements versus mother estimations of pediatric weights

    Directory of Open Access Journals (Sweden)

    Sherafat Akaberian

    2013-06-01

    Full Text Available Background Pediatric resuscitation is challenging for therapeutic group. The most physicians have limited experience in dealing with this situation. Appropriate dosing of the drugs depends on the body weight of the children that it is usually not feasible. There is need for a fast, convenient and reliable method for body weight estimation in children. The aim of this study was to assess the accuracy of Broselow tape in children of Bushehr city. Material and Methods: This cross-sectional study was conducted in the emergency department of Aliasghar hospital. Children were between 1 month and 14 years. Children with chronic disease, 334, ill children were excluded from study. Estimated weight measured based on Broselow tape and actual weight measured by digital scale, then estimated and actual weight were compared. The results were analyzed by SPSS Software Ver 18 and T-Test, Chi-Square Test. Results: findings showed that 43.2% of total subjects were female Mean of age were 43 months. 72.5% of tape body weights were within  10% error of actual body weights. 78.9% of tape body weight was within  15% error of actual body weights. There was no significant difference between boys and girls. Conclusion: Broslow tape was easy, fast and exact for body weight estimation in emergency situation .it is more exact of body weight estimation by parents or therapeutic group so it helps therapeutic group in emergency department for accounting of medication dosage and equipment sizes.

  7. Fast Facts: Recent Statistics from the Library Research Service, Numbers 283-289. January-December, 2010

    Science.gov (United States)

    Library Research Service, 2010

    2010-01-01

    Issues 283 through 289 of "Fast Facts" from the Library Research Service present data collected from libraries in Colorado and throughout the nation. Topics addressed in these "Fast Facts" from 2010 include the relationship between computer access in libraries and use of traditional services, analysis of the third year of data…

  8. Matrix Management: An Organizational Alternative for Libraries.

    Science.gov (United States)

    Johnson, Peggy

    1990-01-01

    Describes various organizational structures and models, presents matrix management as an alternative to traditional hierarchical structures, and suggests matrix management as an appropriate organizational alternative for academic libraries. Benefits that are discussed include increased flexibility, a higher level of professional independence, and…

  9. Effect of athletic taping and kinesiotaping® on measurements of functional performance in basketball players with chronic inversion ankle sprains.

    Science.gov (United States)

    Bicici, Seda; Karatas, Nihan; Baltaci, Gul

    2012-04-01

    Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Crossover Study Design Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping

  10. A Novel Public Library-Based Sexually Transmitted Infection Screening Program for Younger High-Risk Groups in Omaha, Nebraska, USA.

    Science.gov (United States)

    Delair, Shirley F; Lyden, Elizabeth R; O'Keefe, Anne L; Simonsen, Kari A; Nared, Sherri R; Berthold, Elizabeth A; Watanabe-Galloway, Shinobu

    2016-04-01

    Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) are the two most commonly reported sexually transmitted infections (STIs) in the United States (U.S.) and Douglas County, Nebraska has STI rates consistently above the U.S. average. The Douglas County Health Department (DCHD) developed an outreach CT and NG screening program in public libraries to address the problem beyond the traditional STI clinic setting. This study evaluates the effectiveness of the program and identifies factors predictive of CT and NG infections. A retrospective review of surveys of library patrons and DCHD traditional STI clinic clients who submitted urine tests for CT and NG from June 2010 through April 2014 was done. Chi square, Fisher exact, Student's t tests, univariate and multivariate logistic regression were conducted. A total of 977 library records and 4871 DCHD clinic records were reviewed. The percent positive was lower in the library than in the traditional clinic for CT (9.9 vs. 11.2 %) and NG (2.74 vs. 5.3 %) (p = 0.039 and p Library clients were more likely to be 19 years and younger (OR 6.14, 95 % CI: 5.0, 7.5), Black (OR 3.4, 95 % CI: 2.8, 4.1), and asymptomatic (OR 12.4, 95 % CI: 9.9, 15.5) compared to traditional clinic clients. The library STI screening program effectively reaches a younger, asymptomatic, and predominantly Black population compared to a traditional health department clinic site.

  11. Non-contact inline monitoring of thermoplastic CFRP tape quality using air-coupled ultrasound

    Science.gov (United States)

    Essig, W.; Fey, P.; Meiler, S.; Kreutzbruck, M.

    2017-02-01

    Beginning with the aerospace industry, fiber reinforced plastics have spread towards many applications such as automotive, civil engineering as well as sports and leisure articles. Their superior strength and stiffness to mass ratio made them the number one material for achieving high performance. Especially continuous fiber reinforced plastics allow for the construction of structures which are custom tailored to their mechanical loads by adjusting the paths of the fibers to the loading direction. The two main constituents of CFRP are carbon fibers and matrix. Two possibilities for matrix material exist: thermosetting and thermoplastic matrix. While thermosetting matrix may yield better properties with respect to thermal loads, thermoplasticity opens a wide range of applications due to weldability, shapeability, and compatibility to e.g. injection molded thermoplastic materials. Thin (0.1 mm) thermoplastic continuous fiber CFRP tapes with a width of 100 mm were examined using air-coupled ultrasound. Transducers were arranged in reflection as well as transmission setup. By slanted incidence of the ultrasound on the tape surface, guided waves were excited in the material in fiber direction and perpendicular to the fiber direction. Artificial defects - fiber cuts, matrix cuts, circular holes, low velocity impacts from tool drop, and sharp bends - were produced. Experiments on a stationary tape showed good detectability of all artificial defects by guided waves. Also the effects of variation in material properties, fiber volume content and fiber matrix adhesion being the most relevant, on guided wave propagation were examined, to allow for quality assessment. Guided wave measurements were supported by destructive analysis. Also an apparatus containing one endless loop of CFRP tape was constructed and built to simulate inline testing of CFRP tapes, as it would be employed in a CFRP tape production environment or at a CFRP tape processing facility. The influences of tape

  12. Increase of horizontal stiffness for fixing mobile machine with vacuum pad by using filament tapes

    Science.gov (United States)

    Kim, H.-S.; Park, J.-K.; Ro, S.-K.

    2017-08-01

    This paper presents a method to increase fixing stiffness of mobile machine by using filament tapes. Mobile machine moves on a large workpiece for cutting, drilling, welding, and cleaning, etc., so for those works. The vacuum pads are generally used for attaching or detaching objects frequently. Of course, if the object is a metal body, the magnetic force can be used. The vacuum pads have an advantage that it can be used regardless of the magnetic property of the object, but it has a disadvantage that the fixing stiffness is not strong because the material is rubber. That’s why it is difficult to maintain the accurate position of the mobile machine as it could be shaken when being moved or fixed. Thus, this study proposed a method to increase the horizontal fixing stiffness of the mobile machine by using filament tapes to the side of the vacuum pads which compensate the shortcoming of the vacuum pads. Filament tapes are made by inserting special material filaments which have high rigidity into an existing tape to increase tensile strength. In the configuration of the proposed method, the vacuum pad forms the vertical fixing stiffness by suction force, and the filament tape forms the horizontal fixing stiffness by adhesive force. In order to verify the effectiveness of the proposed method, the experimental equipment to measure the fixing stiffness was fabricated, and the comparison experiment was carried out. First, the horizontal fixing stiffness of the vacuum pads and the filament tape was measured respectively as a baseline data, and then the same measurement of the combination of them was performed for the comparison. In addition, another experiment for comparison between Gecko films and filament tape was performed. The results showed that the horizontal fixing stiffness was significantly increased when the filament tape was used together with the vacuum pads, and the Gecko film was not as much effective as the filament tape in terms of the strength of the

  13. Application of LOD Technology in German Libraries and Archives

    Directory of Open Access Journals (Sweden)

    Dong Jie

    2017-12-01

    Full Text Available [Purpose/significance] Linked Open Data (LOD has been widely used in large industries, as well as non-profit organizations and government organizations. Libraries and archives are ones of the early adopters of LOD technology. Libraries and archives promote the development of LOD. Germany is one of the developed countries in the libraries and archives industry, and there are many successful cases about the application of LOD in the libraries and archives. [Method/process] This paper analyzed the successful application of LOD technology in German libraries and archives by using the methods of document investigation, network survey and content analysis. [Result/conclusion] These cases reveal in the traditional field of computer science the relationship among research topics related to libraries and archives such as artificial intelligence, database and knowledge discovery. Summing up the characteristics and experience of German practice can provide more reference value for the development of relevant practice in China.

  14. The Variation of Interface Formation with Slurry Viscosity Change in Side-By-Side Tape Casting

    DEFF Research Database (Denmark)

    Bulatova, Regina; Jabbari, Masoud; Andersen, Kjeld Bøhm

    Homogenous and flexible adjacently graded tapes were produced by casting the organic-based slurries simultaneously. To develop side-by-side tape casing (SBSTC), the material optimization, modernization of the doctor blade design, and parameters control of such processes as casting, drying, de......-bindering and sintering were studied. Solvent and binder concentrations were varied in order to optimize co-casting flow, as well as the drying and sintering shrinkage. Tapes were evaluated in terms of rheological behavior of the slurries, the green and sintered tape microstructure, the quality of the interface area...

  15. Research and development efforts relative to superconducting materials. Final report. [Nb/sub 3/Sn tapes

    Energy Technology Data Exchange (ETDEWEB)

    Adam, E; Beishcher, P; Marancik, W; Lucariello, R; Young, M

    1976-04-01

    Three processes for the production of low-loss superconducting tapes of Nb/sub 3/Sn were investigated. They are the rolled-bronze process, the electron beam (EB) bronze deposition process, and the high-rate sputtering process. Shortly after the start of the investigation, effort on the last two processes was suspended because the process-development time that would be needed to arrive at a suitable transmission-line tape appeared most likely to be the shortest with the rolled-bronze process. Long lengths of Nb/sub 3/Sn tapes were prepared by the rolled-bronze process from extruded and rolled bronze-clad niobium billets. Tapes were stabilized by removing the bronze layer after reaction and then coating the exposed Nb/sub 3/Sn with high-purity copper by EB evaporation. Several meters of high quality Nb/sub 3/Sn tapes were produced by the rolled-bronze process. Even when the tapes were stabilized with copper, the losses were as low as 1.8 ..mu..W/cm/sup 2/ at 4.2 K and a surface current density of 500 rms A/cm. Despite early curtailment of the effort on the EB bronze-deposition process, short samples of Nb/sub 3/Sn tapes were produced.

  16. Ankle taping can reduce external ankle joint moments during drop landings on a tilted surface.

    Science.gov (United States)

    Sato, Nahoko; Nunome, Hiroyuki; Hopper, Luke S; Ikegami, Yasuo

    2017-09-20

    Ankle taping is commonly used to prevent ankle sprains. However, kinematic assessments investigating the biomechanical effects of ankle taping have provided inconclusive results. This study aimed to determine the effect of ankle taping on the external ankle joint moments during a drop landing on a tilted surface at 25°. Twenty-five participants performed landings on a tilted force platform that caused ankle inversion with and without ankle taping. Landing kinematics were captured using a motion capture system. External ankle inversion moment, the angular impulse due to the medio-lateral and vertical components of ground reaction force (GRF) and their moment arm lengths about the ankle joint were analysed. The foot plantar inclination relative to the ground was assessed. In the taping condition, the foot plantar inclination and ankle inversion angular impulse were reduced significantly compared to that of the control. The only component of the external inversion moment to change significantly in the taped condition was a shortened medio-lateral GRF moment arm length. It can be assumed that the ankle taping altered the foot plantar inclination relative to the ground, thereby shortening the moment arm of medio-lateral GRF that resulted in the reduced ankle inversion angular impulse.

  17. The effect of kinesio taping in forward bending of the lumbar spine.

    Science.gov (United States)

    Lemos, Thiago Vilela; Albino, Anna Carolina Gonçalves; Matheus, Joao Paulo C; Barbosa, Aurélio de Melo

    2014-09-01

    [Purpose] The aim of this study was to evaluate the influence of a lumbar fascia Kinesio Taping(®) technique forward bending range of motion. [Subjects and Methods] This was a longitudinal study with a randomized clinical trial composed of 39 subjects divided into three groups (control, Kinesio Without Tension-KWT, and Kinesio Fascia Correction-KFC). The subjects were assessed by Schober and fingertip-to-floor tests and left the tape in place for 48 hours before being reassessed 24 hours, 48 hours and 30 days after its removal. [Results] In all three experimental groups no significant differences were observed with the Schober test, but it was possible to observe an increase in lumbar flexion after 30 days. With the fingertip-to-floor distance assessment, the KFC and KWT groups showed significantly improved flexibility 24 hours and 48 hours after tape removal. [Conclusion] The Kinesio Taping(®) influenced fascia mobility, allowing for slight improvement of lumbar flexibility.

  18. FENDL/C-2.0. Charged-particle reaction data library for fusion applications. Version 1 of March 1997. Data extracted from ENDF/B-6 evaluations. Summary documentation

    International Nuclear Information System (INIS)

    Pashchenko, A.B.; Wienke, H.

    1997-01-01

    This document describes the FENDL/C-2.0 charged-particle reaction data library which is a sublibrary of FENDL-2, the evaluated nuclear data library for fusion applications. This file contains evaluated data in ENDF-6 format for the D(d,n), D(d,p), T(d,n), T(t,2n), He-3(d,p) reactions. The processed information, i.e. Maxwellian-averaged reaction rates, and related quantities, calculated from reaction cross-sections, are also included. The data are available from the Nuclear Data Section online via INTERNET by FTP command, or on magnetic tape upon request. (author)

  19. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    Science.gov (United States)

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  20. INTERACTION OF SEARCH CAPABILITIES OF ELECTRONIC AND TRADITIONAL (CARD CATALOGS

    Directory of Open Access Journals (Sweden)

    Л. В. Головко

    2017-10-01

    Full Text Available Purpose. Interaction of search capabilities of electronic and traditional (card catalogs. Subject: search capabilities of electronic and traditional (card catalogs and their interaction. Goal: Creating efficient search system for library information services, updating and improving the information retrieval system. To reach this goal, following tasks are set: – to determine the possibility of parallel functioning of electronic and traditional card catalogs, and to reveal the interaction of their search capabilities by conducting a survey via questionnaire titled «Interaction of search capabilities of electronic and traditional (card catalogs»; – to find out which search systems are preferred by users; – to estimate the actual condition of search capabilities of electronic and traditional (card catalogs in the library. Methodology. On various stages of the survey the following methods were used: analysis and synthesis, comparison, generalization, primary sources search; sociological method (survey. These methods allowed determining, processing and ana lyzing the whole complex of available sources, which became an important factor of research objectivity. Finding. Survey results allowed us to analyze the dynamics of changes, new needs of the readers, and to make a decision regarding the quality improvement of information search services. Practical value. Creating a theoretical foundation for implementation of set tasks is the practical value of the acquired findings. Conclusions and results of the research can be used in university students’, postgraduates’ and professors’ information search activities. Certain results of the research are used and implemented in practice of the library of Kryvyi Rih State Pedagogical University, namely at workshops on the basics of information culture (using bibliographic reference unit, information search by key words, authors and titles via electronic catalogue. Guides for users were created. Duty

  1. Development of a test procedure for cryogenic adhesive tapes; Entwicklung einer Testprozedur fuer kryogene Klebebaender

    Energy Technology Data Exchange (ETDEWEB)

    Funke, Thomas; Haberstroh, Christoph [TU Dresden (Germany). Bitzer-Professur fuer Kaelte-, Kryo- und Kompressorentechnik; Mayrhofer, Robert; Stipsitz, Johannes [RUAG Space GmbH, Wien (Austria)

    2016-07-01

    At cryostats and dewars for lowest temperatures - especially in connection with liquid-helium cooling at around 4 K, as well at the most applications of the superconductivity - often joints and shutters on the base of low-temperature suited adhesive tapes are required. A current method for the thermal isolation of cold surfaces is their covering with highly reflecting aluminium foils, which are fastened by adhesive aluminium tapes. Selection, usage, and reliability estimation of presumably suited adhesive tapes respectively aluminium tapes occurs presently rather heuristically. A corresponding testing apparature for the measurement of the maximal pulling force was developed and tested by means of a series of test measurements. The testing set-up and measurement results for the validation of the measurement concept with adhesive aluminium tapes are presented in this contribution.

  2. Uranium doping and neutron irradiation of Bi-2223 superconduction tapes for improved critical current density

    International Nuclear Information System (INIS)

    Moss, S.D.; Wang, W.G.; Dou, S.X.; Weinstein, R.

    1998-01-01

    It is demonstrated that a combination of neutron irradiation with uranium doping introduce fission tracks through a Bi-2223 tape which act as effective pinning centres, leading to a substantial increase in critical current. Preliminary data suggests that the combination of uranium doping and neutron irradiation produces improved flux pinning in Bi-2223 tapes over neutron irradiation alone. Before irradiation, SEM, DTA and XRD analyses were performed on the tapes. Both before and after irradiation the trapped maximum magnetic flux was measured at 77K. Before neutron irradiation, uranium doping has no effect on critical current. Preliminary SEM data suggested that the uranium is homogeneously distributed throughout the oxide core of the tape. The presence of 2212 and other secondary phases in the doped tapes suggest further refinement of the sintering procedure is necessary. (authors)

  3. Characteristics of joint resistance with different kinds of HTS tapes for heater trigger switch

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Je Yull; Park, Young Gun; Lee, Woo Seung; Jo, Hyun Chul; Ko, Tae Kuk [Yonsei University, Seoul (Korea, Republic of); Yoon, Yong Soo [Shin Ansan University, Ansan (Korea, Republic of)

    2014-03-15

    Recently, many researches on the system of superconducting power supply and superconducting magnetic energy storage (SMES) using high temperature superconducting (HTS) tapes has been progressed. Those kinds of superconducting devices use the heater trigger switches that have a control delay problem at moments of heating up and cooling down. One way to reduce the time delay is using a different HTS tape at trigger part. For example, HTS tape having lower critical temperature can reduce time delay of heating up and heating down stage for heater trigger operation. This paper deals with resistances joint with different kinds of HTS tapes which have different properties to verify usefulness of the suggested method. Three kinds of commercial HTS tapes with different specifications are selected as samples and two kinds of solders are used for comparison. Joint is performed with temperature and pressure controllable joint machine and the joint characteristics are analyzed under the repeatable conditions.

  4. 'Twisted tape sign': Its significance in recurrent sigmoid volvulus

    International Nuclear Information System (INIS)

    Gopal, K.; Lim, Y.; Banerjee, B.

    2005-01-01

    Aim: Sigmoid volvulus is a common cause of intestinal obstruction in the elderly. Mild attacks of sigmoid volvulus may be more difficult to diagnose due to the lack of severity of symptoms which may resolve spontaneously only to recur after an interval. This study was a review of patients to assess the incidence of the 'twisted tape sign' and to evaluate the significance of its presence in cases of recurrent sigmoid volvulus. Methods and materials: A retrospective study over eight years revealed six cases of surgically confirmed recurrent sigmoid volvulus. Case records and barium enemas of all patients were reviewed. Results: Six patients were identified, including four men and two women, with a median age of 56 years. Diagnostic difficulties were encountered in four (67%) patients with a delay ranging between 10 and 37 months with a mean 17.3 months. Twisted tape sign was confirmed on all barium examinations retrospectively. Conclusion: Recognition of twisted tape sign on barium enema examination along with an appropriate clinical history would suggest a diagnosis of recurrent sigmoid volvulus

  5. Design and Test of a Thermal Triggered Persistent Current System using High Temperature Superconducting Tapes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Keun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Kang, Hyoungku [Electro-Mechanical Research Institute, Hyundai Heavy Industries, Yongin (Korea, Republic of); Ahn, Min Cheol [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yang, Seong Eun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yoon, Yong Soo [Department of Electrical Engineering, Ansan College of Technology, 671 Choji-Dong, Danwon-Gu, Ansan, 425-792 (Korea, Republic of); Lee, Sang Jin [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Ko, Tae Kuk [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of)

    2006-06-01

    A superconducting magnet which is operated in persistent current mode in SMES, NMR, MRI and MAGLEV has many advantages such as high uniformity of magnetic field and reduced thermal loss. A high temperature superconducting (HTS) persistent current switch (PCS) system was designed and tested in this research. The HTS PCS was optimally designed using two different HTS tapes, second generation coated conductor (CC) HTS tape and Bi-2223 HTS tape by the finite element method (FEM) in thermal quench characteristic view. The CC tape is more prospective applicable wire in these days for its high n value and critical current independency from external magnetic field than Bi-2223 tape. Also a prototype PCS system using Bi-2223 tape was manufactured and tested. The PCS system consists of a PCS part, a heater which induces the PCS to quench, and a superconducting magnet. The test was performed in various conditions of transport current. An initial current decay appeared when the superconducting magnet was energized in a PCS system was analyzed. This paper would be foundation of HTS PCS researches.

  6. What Public Libraries Must Do To Survive.

    Science.gov (United States)

    St. Lifer, Evan

    2001-01-01

    Considers the challenges facing public libraries in meeting the current needs of its users while still delivering traditional information and recreational services. Topics include keeping up with technological trends; recruitment, staffing, and continuing education; the role as community center; and creating effective marketing strategies. (LRW)

  7. Sun StorageTek T9940 Tape Drive

    CERN Multimedia

    2002-01-01

    Technology allowed reuse of the same data cartridge at higher capacity with later model of the tape drive hence offering significant savings of the media cost. It has been use by the CERN from 2002 to 2008.

  8. Comparison study of cable geometries and superconducting tape layouts for high-temperature superconductor cables

    Science.gov (United States)

    Ta, Wurui; Shao, Tianchong; Gao, Yuanwen

    2018-04-01

    High-temperature superconductor (HTS) rare-earth-barium-copper-oxide (REBCO) tapes are very promising for use in high-current cables. The cable geometry and the layout of the superconducting tapes are directly related to the performance of the HTS cable. In this paper, we use numerical methods to perform a comparison study of multiple-stage twisted stacked-tape cable (TSTC) conductors to find better cable structures that can both improve the critical current and minimize the alternating current (AC) losses of the cable. The sub-cable geometry is designed to have a stair-step shape. Three superconducting tape layouts are chosen and their transport performance and AC losses are evaluated. The magnetic field and current density profiles of the cables are obtained. The results show that arrangement of the superconducting tapes from the interior towards the exterior of the cable based on their critical current values in descending order can enhance the cable's transport capacity while significantly reducing the AC losses. These results imply that cable transport capacity improvements can be achieved by arranging the superconducting tapes in a manner consistent with the electromagnetic field distribution. Through comparison of the critical currents and AC losses of four types of HTS cables, we determine the best structural choice among these cables.

  9. Progress in Jc and magnetic field performance of Bi-2223/Ag composite tapes

    International Nuclear Information System (INIS)

    Savvides, N.; Katsaros, A.; Reilly, D.; Thorley, A.; Herrmann, J.

    1998-01-01

    Full text: The application of high-temperature superconductors to electric power systems is actively pursued by several commercial teams around the world. A promising candidate is the Bi-2223/Ag composite superconductor. For large scale commercial applications the conductor must meet certain engineering specifications including high current capacity in the presence of a self-generated magnetic field ranging from a few hundred mT in transmission cables to 1-2 T in transformers and current limiters, and to much higher fields in the case of superconducting coils for energy storage and magnets. In the last two years, a commercial consortium consisting of Metal Manufactures Ltd, University of Wollongong and CSIRO has focused on the development of Bi-2223/Ag composite tape suitable for use in electric power applications. The powder-in-tube process is used to produce conventional single filament and multifilament tapes and twisted conductors. An appropriate measure of 'process capability' is routine running of the process and evaluation of tape performance. In this paper we report on the electrical properties of Bi-2223/Ag composite tapes produced as part of the long-length product development. The transport critical current density of tapes is measured in magnetic fields up to 9 T (H parallel and H perpendicular tape-plane) and as a function of temperature (4 - 80 K). Transport ac losses are determined at 77 K and 60 Hz, and the bend strain performance is determined at 77 K for strains up to 1.5 %

  10. Automatic storage of single gamma spectra on magnetic tape. Programs Longo, Dire

    International Nuclear Information System (INIS)

    Los Arcos Merino, J.M.

    1978-01-01

    The program Longo provides the block size and the black number in a binary file on magnetic tape. It has been applied to analyse the structure of the nine-track magnetic tapes storing single or coincidence gamma spectra files, recorded in octet form by a Multi-8 minicomputer in the Nuclear Spectrometry Laboratory of J.E.N. Then the program Dire has been written to transform the single gamma spectra into a new Fastrand disk file, storing the information in 36 bit words. A copy of this file is obtained on magnetic tape and the single gamma spectra are then availables by standard Fortran V reading sentences. (author)

  11. Automatic storing of single gamma spectra on magnetic tape. Programs LONGO, DIRE

    International Nuclear Information System (INIS)

    Los Arcos Merino, J. M.

    1978-01-01

    The program LONGO provides the block size and the block number in a binary file on magnetic tape. It has been applied to analyse the structure of the nine-track magnetic tapes storing single or coincidence gamma spectra files, recorded in octet form by a MULTI-8 minicomputer in the Nuclear Spectrometry Laboratory of J.E.N. Then the program DIRE has been written to transform the single gamma spectra into a new FASTRAND disk file, storing the information in-36 bit words. A copy of this file is obtained on magnetic tape and the single gamma spectra are then available by standard FORTRAN V reading sentences. (Author) 3 refs

  12. Research on new information service model of the contemporary library

    International Nuclear Information System (INIS)

    Xin Pingping; Lu Yan

    2010-01-01

    According to the development of the internet and multimedia technology, the information service models in the contemporary library become both of the traditional and digital information service. The libraries in each country do their best to make the voluminous information and the complex technology be High-integrated in the background management, and also make the front interface be more and more convenient to the users. The essential characteristics of the information service of the contemporary library are all-in-one and humanness. In this article, we will describe several new hot information service models of the contemporary library in detail, such as individualized service, reference service, reference service and strategic information service. (authors)

  13. The Role and Responsibility of the University Library in Publishing in a University

    Directory of Open Access Journals (Sweden)

    Bas Savenije

    2000-06-01

    Full Text Available As a consequence of developments in information technology, the traditional information chain is subject to change: the separate functions in this chain become more and more integrated and the roles played by the traditional parties are most uncertain. Several new models in scholarly publishing and communication are emerging, in which the scientific community and the scientists themselves play a central role. It is more than natural for universities to support these developments in order to realise new models of scientific communication that are more in tune with the needs of the academic community than the traditional model, which has led to a serious serials crisis. An important step in this direction is that each university encourages scientists to make more use of ICT in their research publications. However, it is also necessary to give serious attention to organisational matters: in this respect every university should take responsibility for collecting, archiving and disclosing the scientific output of its own scientists. The provision of scientific information is the traditional core business of university libraries and it is a natural extension of this role for university libraries to support this development and to organise the processes needed. The paper describes the role that universities and their libraries have to play. It also gives some examples of library initiatives in this field, including an evaluation of their impact on the innovation of scientific communication.

  14. Performance Assessment in a Heat Exchanger Tube with Opposite/Parallel Wing Twisted Tapes

    Directory of Open Access Journals (Sweden)

    S. Eiamsa-ard

    2015-02-01

    Full Text Available The thermohydraulic performance in a tube containing a modified twisted tape with alternate-axes and wing arrangements is reported. This work aims to investigate the effects of wing arrangements (opposite (O and parallel (P wings at different wing shapes (triangle (Tri, rectangular (Rec, and trapezoidal (Tra wings and on the thermohydraulic performance characteristics. The obtained results show that wing twisted tapes with all wing shape arrangements (O-Tri/O-Rec/O-Tra/P-Tri/P-Rec/P-Tra give superior thermohydraulic performance and heat transfer rate to the typical twisted tape. In addition, the tapes with opposite wing arrangement of O-Tra, O-Rec, and O-Tri give superior thermohydraulic performances to those with parallel wing arrangement of P-Tra, P-Rec, and P-Tri around 2.7%, 3.5%, and 3.2%, respectively.

  15. Developing a library of authenticated Traditional Chinese Medicinal (TCM) plants for systematic biological evaluation--rationale, methods and preliminary results from a Sino-American collaboration.

    Science.gov (United States)

    Eisenberg, David M; Harris, Eric S J; Littlefield, Bruce A; Cao, Shugeng; Craycroft, Jane A; Scholten, Robert; Bayliss, Peter; Fu, Yanling; Wang, Wenquan; Qiao, Yanjiang; Zhao, Zhongzhen; Chen, Hubiao; Liu, Yong; Kaptchuk, Ted; Hahn, William C; Wang, Xiaoxing; Roberts, Thomas; Shamu, Caroline E; Clardy, Jon

    2011-01-01

    While the popularity of and expenditures for herbal therapies (aka "ethnomedicines") have increased globally in recent years, their efficacy, safety, mechanisms of action, potential as novel therapeutic agents, cost-effectiveness, or lack thereof, remain poorly defined and controversial. Moreover, published clinical trials evaluating the efficacy of herbal therapies have rightfully been criticized, post hoc, for their lack of quality assurance and reproducibility of study materials, as well as a lack of demonstration of plausible mechanisms and dosing effects. In short, clinical botanical investigations have suffered from the lack of a cohesive research strategy which draws on the expertise of all relevant specialties. With this as background, US and Chinese co-investigators with expertise in Traditional Chinese Medicine (TCM), botany, chemistry and drug discovery, have jointly established a prototype library consisting of 202 authenticated medicinal plant and fungal species that collectively represent the therapeutic content of the majority of all commonly prescribed TCM herbal prescriptions. Currently housed at Harvard University, the library consists of duplicate or triplicate kilogram quantities of each authenticated and processed species, as well as "detanninized" extracts and sub-fractions of each mother extract. Each species has been collected at 2-3 sites, each separated geographically by hundreds of miles, with precise GPS documentation, and authenticated visually and chemically prior to testing for heavy metals and/or pesticides contamination. An explicit decision process has been developed whereby samples with the least contamination were selected to undergo ethanol extraction and HPLC sub-fractionation in preparation for high throughput screening across a broad array of biological targets including cancer biology targets. As envisioned, the subfractions in this artisan collection of authenticated medicinal plants will be tested for biological activity

  16. FENDL/E. Evaluated nuclear data library of neutron nuclear interaction cross-sections and photon production cross-sections and photon-atom interaction cross sections for fusion applications. Version 1.1 of November 1994

    International Nuclear Information System (INIS)

    Pashchenko, A.B.; Wienke, H.; Ganesan, S.; McLaughlin, P.K.

    1996-01-01

    This document presents the description of a physical tape containing the basic evaluated nuclear data library of neutron nuclear interaction cross-sections and photon production cross-sections and photon-atom interaction cross-sections for fusion applications. It is part of FENDL, the evaluated nuclear data library for fusion applications. The nuclear data are available cost-free for distribution to interested scientists upon request. The data can also be retrieved by the user via online access through international computer networks. (author). 11 refs, 1 tab

  17. Current distribution and enhancement of the engineering critical current density in multifilament Bi-2223 tapes

    DEFF Research Database (Denmark)

    Wang, W.G.; Jensen, M.B.; Kindl, B.

    2000-01-01

    The spatial distribution of the critical current density (Jc) and engineering critical current density (Je) along the tape width direction was studied by a cutting technique on Bi-2223 multifilamentary tapes. In general, an increase of Jc towards the centre of the tape was measured. We attribute...... microstructure with a great amount of secondary phases. Local variation of Jc was measured within the centre segment of the tape. This indicates the influence of other factors on Jc, such as filament shape, connectivity of the filaments, and sausaging. Enhancement of Je has been pursued in which average Je of 12...

  18. Numerical Analysis of Heat transfer Enhancement in a double pipe heat exchanger with a holed twisted tape

    Directory of Open Access Journals (Sweden)

    Kumar Akarsh

    2018-01-01

    Full Text Available In the present study numerical analysis of enhancement in heat transfer characteristics in a double pipe heat exchanger is studied using a holed twisted tape.The twisted tape with a constant twist ratio is inserted in a double pipe heat exchanger. Holes of diameter 1mm, 3 mm and 5 mm were drilled at regular pitch throughout the length of the tape. Numerical modeling of a double pipe heat exchanger with the holed twisted tape was constructed considering hot fluid flowing in the inner pipe and cold fluid through the annulus.Simulation was done for varied mass flow rates of hot fluid in the turbulent condition keeping the mass flow rate of cold fluid being constant. Thermal properties like Outlet temperatures, Nusselt number, overall heat transfer coefficient, heat transfer rate and pressure drop were determined for all the cases. Results indicated that normaltwisted tape without holes performed better than the bare tube. In the tested range of mass flow rates the average Nusselt number and heat transfer rate were increased by 85% and 34% respectively. Performance of Twisted tape with holes was slightly reduced than the normal twisted tape and it deteriorated further for higher values hole diameter. Pressure drop was found to be higher for the holed twisted tape than the normal tape.

  19. Ceramic tape casting: A review of current methods and trends with emphasis on rheological behaviour and flow analysis

    International Nuclear Information System (INIS)

    Jabbari, M.; Bulatova, R.; Tok, A.I.Y.; Bahl, C.R.H.; Mitsoulis, E.; Hattel, J.H.

    2016-01-01

    Highlights: • Brief review of the tape casting process for ceramics. • Role of fluid flow analysis in tape casting of ceramics. • Rheological classification of common fluids in tape casting. • Review of commonly used rheological behaviour for ceramics in tape casting. - Abstract: Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Today, tape casting is the basic fabrication process that provides multilayered capacitors and multilayered ceramic packages. In tape casting the rheological behaviour of the slurry as well as the material flow during casting are of utmost importance since these phenomena to a large extent determine the final properties and hence the quality of the cast product. During the last decades this has led to an increasing number of works in literature within fluid flow analysis of tape casting. In the present paper a review of the development of the tape casting process with particular focus on the rheological classifications as well as modelling the material flow is hence presented and in this context the current status is examined and future potential discussed.

  20. Ceramic tape casting: A review of current methods and trends with emphasis on rheological behaviour and flow analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jabbari, M., E-mail: mjab@mek.dtu.dk [Process Modelling Group, Department of Mechanical Engineering, Technical University of Denmark, Nils Koppels Allé, 2800 Kgs. Lyngby (Denmark); Bulatova, R. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, Building 779, Roskilde (Denmark); Tok, A.I.Y. [School of Materials Science & Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Bahl, C.R.H. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, Building 779, Roskilde (Denmark); Mitsoulis, E. [School of Mining Engineering and Metallurgy, National Technical University of Athens, Zografou, 15780 Athens (Greece); Hattel, J.H. [Process Modelling Group, Department of Mechanical Engineering, Technical University of Denmark, Nils Koppels Allé, 2800 Kgs. Lyngby (Denmark)

    2016-10-15

    Highlights: • Brief review of the tape casting process for ceramics. • Role of fluid flow analysis in tape casting of ceramics. • Rheological classification of common fluids in tape casting. • Review of commonly used rheological behaviour for ceramics in tape casting. - Abstract: Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Today, tape casting is the basic fabrication process that provides multilayered capacitors and multilayered ceramic packages. In tape casting the rheological behaviour of the slurry as well as the material flow during casting are of utmost importance since these phenomena to a large extent determine the final properties and hence the quality of the cast product. During the last decades this has led to an increasing number of works in literature within fluid flow analysis of tape casting. In the present paper a review of the development of the tape casting process with particular focus on the rheological classifications as well as modelling the material flow is hence presented and in this context the current status is examined and future potential discussed.

  1. The effect of tape casting operational parameters on the quality of adjacently graded ceramic film

    DEFF Research Database (Denmark)

    Bulatova, Regina; Gudik-Sørensen, Mads; Della Negra, Michela

    2016-01-01

    For small length tape casting of ceramic slurries varying green film thickness is often a problem. To optimise this, the following parameters were investigated: single blade, double blade, using a pump system and a modelled speed change mode have been analysed. Advantages and limitations of every...... method are described here. The tape casting experiments were built to be generic in order to allow the control of various processing conditions. From these results, the single-blade technique was chosen for a study of side-by-side tape casting. The influence of the geometric parameters of partitioning...... the casting tank into chambers, on the quality of graded tape was studied. Tape casting experiments at different speeds and partition tongue lengths in combination with rheological tests revealed that high casting speeds and absence of the partition under the blade are detrimental to the formation...

  2. Influence of powder pre-annealing on the phase formation and critical current of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Chen, X.P.; Grivel, Jean-Claude; Li, M.Y.

    2004-01-01

    . The effects of different precursors were investigated by XRD, SEM/EDS and critical current measurements. It has been found that both the microstructure and phase formation depended strongly on the different lead-rich phases, which determined the reactivity of the precursor. Tapes fabricated using...... the precursor with Ca2PbO4 phase (tape T1) had lower transformation rate of 2223 phase than tapes fabricated using the precursor with 3321 phase (tape T2). SEM results show that a large fraction of secondary phases with big particle size was formed in the tape T1 during the subsequent sintering, which might...

  3. The Islamic Bookbinding Tradition. A Book Archaeological Study

    NARCIS (Netherlands)

    Scheper, Catharina Helena (Karin)

    2014-01-01

    The technique of Islamic bookbinding explores the development of the bookbinding tradition in the Islamic world. Based on an assessment of the collections in the University Library Leiden, the various sewing techniques, constructions and the application of covering materials are described in detail.

  4. Electromechanical characterization of superconducting wires and tapes at 77 K

    CERN Document Server

    Bjoerstad, Roger

    The strain dependency of the critical current in state-of-the-art cuprate high-temperature superconductors (HTS) has been characterized. A universal test machine (UTM) combined with a critical current measurement system has been used to characterize the mechanical and the superconducting properties of conductors immersed in an open liquid nitrogen dewar. A set-up has been developed in order to perform simultaneous measurements of the superconductor lattice parameter changes, critical current, as well as the stress and strain at 77 K in self-field in a high energy synchrotron beamline. The HTS tapes and wires studied were based on YBCO, Bi-2223 and Bi-2212. The YBCO tapes were produced by SuperPower and American Superconductors (AMSC). Two types of Bi-2223 tapes, HT and G, were produced by Sumitomo Electric Industries (SEI). The Bi-2212 wires were produced by Oxford Superconducting Technology (OST) using Nexans granulate precursor, before undergoing a specialized over pressure (OP) processing and heat treatmen...

  5. Effects of differently hardened brass foil laminate on the electromechanical property of externally laminated CC tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Mean, Byoung Jean; Lee, Jae Hun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-12-15

    The mechanical properties of REBCO coated conductor (CC) wires under uniaxial tension are largely determined by the thick component layers in the architecture, namely, the substrate and the stabilizer or even the reinforcement layer. Depending on device applications of the CC tapes, it is necessary to reinforce thin metallic foils externally to one-side or both sides of the CC tapes. Due to the external reinforcement of brass foils, it was found that this could increase the reversible strain limit from the Cu-stabilized CC tapes. In this study, the effects of differently hardened brass foil laminate on the electromechanical property of CC tapes were investigated under uniaxial tension loading. The tensile strain dependence of the critical current (I{sub c}) was measured at 77 K and self-field. Depending on whether the I{sub c} of CC tapes were measured during loading or after unloading, a reversible strain (or stress) limit could be determined, respectively. The both-sides of the Cu-stabilized CC tapes were laminated with brass foils with different hardness, namely 1/4H, 1H and EH. From the obtained results, it showed that the yield strength of the brass laminated CC tapes with EH brass foil laminate was comparable to the one of the Cu-stabilized CC tape due to its large yield strength even though its large volume fraction. It was found that the brass foil with different hardness was mainly sensitive on the stress dependence of I{sub c}, but not on the strain sensitivity due to the residual strain induced in the laminated CC tapes during unloading.

  6. Learning Outcomes and Affective Factors of Blended Learning of English for Library Science

    Science.gov (United States)

    Wentao, Chen; Jinyu, Zhang; Zhonggen, Yu

    2016-01-01

    English for Library Science is an essential course for students to command comprehensive scope of library knowledge. This study aims to compare the learning outcomes, gender differences and affective factors in the environments of blended and traditional learning. Around one thousand participants from one university were randomly selected to…

  7. Quality of life and objective outcome assessment in women with tape division after surgery for stress urinary incontinence.

    Directory of Open Access Journals (Sweden)

    Daniela Ulrich

    Full Text Available Midurethral tapes may cause long-term complications such as voiding dysfunction, groin pain, de novo urgency or mesh erosion, which necessitate a reoperation. There is a paucity of data regarding health related quality of life in patients undergoing tape removal. The aim of the study was to evaluate quality of life (QoL and objective outcome after midurethral tape division or excision.All patients who underwent a midurethral tape division for voiding difficulties, pain or therapy resistant de novo overactive bladder between 1999 and 2014 were invited for follow-up. A control group with a suburethral tape without division was established in a 1:2 ratio and matched for age, tape used and year of tape insertion. Patients completed the Kings´ Health Questionnaire (KHQ, Incontinence Outcome Questionnaire, Female Sexual Function Index Questionnaire and the Patient Global Impression of Improvement score.Tape division or excision was performed in 32 women. Overall, 15 (60% of 25 women who were alive were available for clinical examination and completed the questionnaires. Tape division was performed for voiding dysfunction (n = 7, overactive bladder (n = 2, mesh extrusion (n = 3 and ongoing pain (n = 3. Median time to tape division/excision was 10 months. Three women in the tape division group had undergone reoperation for stress urinary incontinence (SUI. At a median follow-up of 11 years (IQR 9-13 subjective SUI rate was 53% (8/15 women in the tape division group and 17% (5/30 in the control group (p = 0.016, with no significant differences in objective SUI rates between groups. With regard to quality of life, the study group had significantly worse scores in the SUI related domains role limitation, physical limitation, severity measures and social limitations (KHQ compared to the control group.Women needing tape division or excision have lower SUI related QoL scores compared to controls mostly because of higher subjective SUI rates.

  8. The effectiveness of Kinesio Taping on pain and disability in cervical myofascial pain syndrome

    Directory of Open Access Journals (Sweden)

    Saime Ay

    Full Text Available Abstract Objective: The aim of this study was to investigate the effectiveness of Kinesio Taping and sham Kinesio Taping on pain, pressure pain threshold, cervical range of motion, and disability in cervical myofascial pain syndrome patients (MPS. Methods: This study was designed as a randomized, double-blind placebo controlled study. Sixty-one patients with MPS were randomly assigned into two groups. Group 1 (n = 31 was treated with Kinesio Taping and group 2 (n = 30 was treated sham taping five times by intervals of 3 days for 15 days. Additionally, all patients were given neck exercise program. Patients were evaluated according to pain, pressure pain threshold, cervical range of motion and disability. Pain was assessed by using Visual Analog Scale, pressure pain threshold was measured by using an algometer, and active cervical range of motion was measured by using goniometry. Disability was assessed with the neck pain disability index disability. Measurements were taken before and after the treatment. Results: At the end of the therapy, there were statistically significant improvements on pain, pressure pain threshold, cervical range of motion, and disability (p 0.05. Conclusion: This study shows that Kinesio Taping leads to improvements on pain, pressure pain threshold and cervical range of motion, but not disability in short time. Therefore, Kinesio Taping can be used as an alternative therapy method in the treatment of patients with MPS.

  9. Effects of Patellofemoral Taping on Patellofemoral Joint Alignment and Contact Area During Weight Bearing.

    Science.gov (United States)

    Ho, Kai-Yu; Epstein, Ryan; Garcia, Ron; Riley, Nicole; Lee, Szu-Ping

    2017-02-01

    Study Design Controlled laboratory study. Background Although it has been theorized that patellofemoral joint (PFJ) taping can correct patellar malalignment, the effects of PFJ taping techniques on patellar alignment and contact area have not yet been studied during weight bearing. Objective To examine the effects of 2 taping approaches (Kinesio and McConnell) on PFJ alignment and contact area. Methods Fourteen female subjects with patellofemoral pain and PFJ malalignment participated. Each subject underwent a pretaping magnetic resonance imaging (MRI) scan session and 2 MRI scan sessions after the application of the 2 taping techniques, which aimed to correct lateral patellar displacement. Subjects were asked to report their pain level prior to each scan session. During MRI assessment, subjects were loaded with 25% of body weight on their involved/more symptomatic leg at 0°, 20°, and 40° of knee flexion. The outcome measures included patellar lateral displacement (bisect-offset [BSO] index), mediolateral patellar tilt angle, patellar height (Insall-Salvati ratio), contact area, and pain. Patellofemoral joint alignment and contact area were compared among the 3 conditions (no tape, Kinesio, and McConnell) at 3 knee angles using a 2-factor, repeated-measures analysis of variance. Pain was compared among the 3 conditions using the Friedman test and post hoc Wilcoxon signed-rank tests. Results Our data did not reveal any significant effects of either McConnell or Kinesio taping on the BSO index, patellar tilt angle, Insall-Salvati ratio, or contact area across the 3 knee angles, whereas knee angle had a significant effect on the BSO index and contact area. A reduction in pain was observed after the application of the Kinesio taping technique. Conclusion In a weight-bearing condition, this preliminary study did not support the use of PFJ taping as a medial correction technique to alter the PFJ contact area or alignment of the patella. J Orthop Sports Phys Ther 2017

  10. Between the Sheets: a Library-wide Inventory with Google

    Directory of Open Access Journals (Sweden)

    Craig Boman

    2017-10-01

    Full Text Available When it comes to taking an inventory of physical items, libraries often rely on their traditional integrated library system’s (ILS à la carte add ons; outside vendors; or other possibly outdated, complex, and often expensive methods. For libraries with shrinking budgets and other limited resources, high costs can put these methods out of reach. At the University of Dayton Libraries, we set out to develop an inexpensive and reasonably easy-to-use method for conducting a library-wide physical item inventory. In this article, we explain a custom built Google Sheets-based library inventory system, along with some code for the implementation of a RESTful API (written in PHP that interacts with our ILS. We will also explain our use of Google Apps scripts in our Google Sheet, which are crucial to our systems. Although this method used a specific ILS (Innovative Interfaces' Sierra product and custom-built RESTful APIs, it may be possible to use similar approaches with other ILS software. Additional notes include areas for improvement and recommendations for interoperability with other ILS systems.

  11. Low back pain during pregnancy and Kinesio tape application.

    Science.gov (United States)

    Reyhan, Aycan Çakmak; Dereli, Elif Elçin; Çolak, Tuğba Kuru

    2017-01-01

    Low back pain is a common problem during pregnancy. Although the pain usually occurs in the third trimester, it might be seen in the first trimester, too. There are various types of applications for the treatment of low back pain during pregnancy. However, there is a lack of evidence for the effectiveness of each method. If there is not an obvious deficit, bed rest, exercise, conventional physiotherapy, using protective principles for the lumbar area are recommended, since the main and the only complaint is low back pain. It is aimed in the current review to investigate the use of Kinesio tape in the low back pain seen during pregnancy and to review the literature related to this subject. There are only a few studies investigating the effect of Kinesio tape during pregnancy in the literature and they mostly did not aim to study the low back pain, further evidence and studies are needed to investigate the use of Kinesio tape for the low back pain seen during pregnancy as there is not evidence strong enough. Kinesiotape application aims to increase circulation and mobility, and regarding these gains decreased pain and increased performance are expected.

  12. From Libraries to ‘Libratories’

    Directory of Open Access Journals (Sweden)

    Leo Waaijers

    2006-04-01

    Full Text Available While the eighties of the last century were a time of local automation for libraries and the nineties the decade in which libraries embraced the internet and the WWW, now is the age in which the big search engines and institutional repositories are gaining a firm footing. This heralds a new era in both the evolution of scholarly communication and its agencies themselves, i.e. the libraries. Until now libraries and publishers have developed a digital variant of existing processes and products, i.e. catalogues posted on the Web, scanned copies of articles, e-mail notification about acquisitions or expired lending periods, or traditional journals in a digital jacket. However, the new OAI repositories and services based upon them have given rise to entirely new processes and products, libraries transforming themselves into partners in setting up virtual learning environments, building an institution’s digital showcase, maintaining academics’ personal websites, designing refereed portals and – further into the future – taking part in organising virtual research environments or collaboratories. Libraries are set to metamorphose into ‘libratories’, an imaginary word to express their combined functions of library, repository and collaboratory. In such environments scholarly communication will be liberated from its current copyright bridle while its coverage will be both broader - including primary data, audiovisuals and dynamic models - and deeper, with cross-disciplinary analyses of methodologies and applications of instruments. Universities will make it compulsory to store in their institutional repositories the results of research conducted within their walls for purposes of academic reporting, review committees, and other modes of clarification and explanation. Big search engines will provide access to this profusion of information and organise its mass customisation.

  13. Microstructure and superconducting properties of Bi-2223/Ag tapes fabricated in the two-step sintering process

    International Nuclear Information System (INIS)

    Lu, X.Y.; Nagata, A.; Sugawara, K.

    2008-01-01

    The microstructure and superconducting properties of Bi-2223/Ag tapes fabricated in the two-step sintering process were investigated. The tapes were then subjected to two heat treatments with an intermediate rolling. All the tapes were sintered at 835 deg. C for 24 h at initial sintering stage. A two-step sintering procedure was then used in the final sintering stage. In the first step, the tapes are sintered at 840-865 deg. C for 1 h. In the second step, they were sintered at 835 deg. C for 120 h. The results show that the first step sintering temperature has significant influence on the microstructure and the critical current density J c . The observed microstructures are consistent well with the different J c performances of the tapes first-step-sintered at different temperatures. The tape first-step-sintered at 850 deg. C, which has small secondary phases, stronger c-axis grain alignment, higher proportion of Bi-2223 phase, and no cracks, exhibits the highest J c value

  14. Short-Term Effects of Kinesio Taping on Muscle Recruitment Order During a Vertical Jump: A Pilot Study.

    Science.gov (United States)

    Mendez-Rebolledo, Guillermo; Ramirez-Campillo, Rodrigo; Guzman-Muñoz, Eduardo; Gatica-Rojas, Valeska; Dabanch-Santis, Alexis; Diaz-Valenzuela, Francisco

    2018-06-22

    Kinesio taping is commonly used in sports and rehabilitation settings with the aim of prevention and treatment of musculoskeletal injuries. However, limited evidence exists regarding the effects of 24 and 72 hours of kinesio taping on trunk and lower limb neuromuscular and kinetic performance during a vertical jump. The purpose of this study was to analyze the short-term effects of kinesio taping on height and ground reaction force during a vertical jump, in addition to trunk and lower limb muscle latency and recruitment order. Single-group pretest-posttest. University laboratory. Twelve male athletes from different sports (track and field, basketball, and soccer). They completed a single squat and countermovement jump at basal time (no kinesio taping), 24, and 72 hours of kinesio taping application on the gluteus maximus, biceps femoris, rectus femoris, gastrocnemius medialis, and longissimus. Muscle onset latencies were assessed by electromyography during a squat and countermovement jump, in addition to measurements of the jump height and normalized ground reaction force. The kinesio taping had no effect after 24 hours on either the countermovement or squat jump. However, at 72 hours, the kinesio taping increased the jump height (P = .02; d = 0.36) and normalized ground reaction force (P = .001; d = 0.45) during the countermovement jump. In addition, 72-hour kinesio taping reduced longissimus onset latency (P = .03; d = 1.34) and improved muscle recruitment order during a countermovement jump. These findings suggest that kinesio taping may improve neuromuscular and kinetic performance during a countermovement jump only after 72 hours of application on healthy and uninjured male athletes. However, no changes were observed on a squat jump. Future studies should incorporate a control group to verify kinesio taping's effects and its influence on injured athletes.

  15. BibliOpass – An Open Library Network in Switzerland

    Directory of Open Access Journals (Sweden)

    Alexis Rivier

    2006-04-01

    Full Text Available The idea underlying BibliOpass is very simple: extending borrowers' rights to all libraries participating in the network. As in other countries, users of Swiss libraries are more and more mobile, especially the categories of students, teachers or researchers. Universities and technology institute have become more specialized and less general, aiming to improve their reputation at an international level. Students often need to visit different universities during their studies. BibliOpass supports this trend regarding library use in relation to this new mobility. Strangely, similar projects in other countries are not so frequent: Sconul Research Extra in Great Britain which groups together more than 150 higher education institutions is the best example. Basically, BibliOpass makes it simpler for a borrower to use other libraries. More than 600 libraries throughout the country are at present involved in the BibliOpass network. A patron registered as a ‘normal user’ in his or her main library (called ‘Home library’ may borrow items in any other library (called ‘Guest library’ without needing to obtain a new user card or paying extra fees. The user must observe the rules of the guest library (for example number of items and duration of loan. Items must be returned to their originating library for management reasons. BibliOpass is a new, complementary service to Inter Library Loan (ILL, the traditional way to obtain books from other libraries.

  16. Adult Education in Museums and Public Libraries.

    Science.gov (United States)

    Miller, Harry G.

    Both museums and public libraries are available sources of education for adults. Besides their traditional functions of collecting and preserving items from human artistic or scientific history, museums have taken on a more active role in educating the public, particularly adults. Some educational services provided by museums are dioramas, period…

  17. Applied rolling and sensitivity of Bi(2223)/Ag tapes on Ic degradation by mechanical stress

    International Nuclear Information System (INIS)

    Kovac, P.; Bukva, P.; Husek, I.; Richens, P.E.; Jones, H.

    1999-01-01

    An experimental study of multicore Bi(2223)/Ag tapes, roll-sintered by different methods and subjected to bending and tension stresses has been performed. The tapes, of various technological histories, were bent and tensioned and subsequently the transport current was measured at each stressed state. Comparison of I c degradation curves shows that applied rolling may influence the sensitivity of Bi-2223 filaments against the mechanical stress. The existence of transverse microcracks caused by intermediate rolling leads to a higher sensitivity of the tape to bending. A lowering of critical current degradation was observed for two-axially rolled tapes having a higher filament density and better homogeneity prior to sintering treatment. (author)

  18. Functionally Graded Ceramics Fabricated with Side-by-Side Tape Casting for Use in Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Bulatova, Regina; Bahl, Christian; Andersen, Kjeld Bøhm

    2015-01-01

    Functionally graded ceramic tapes have been fabricated by a side-by-side tape casting technique. This study shows the possibility and describes the main principles of adjacent coflow of slurries resulting in formation of thin plates of graded ceramic material. Results showed that the small...... variations of solvent and binder system concentrations have a substantial effect on slurry viscosity. Varying these parameters showed that side-by-side tape casting with a well-defined interface area is possible for slurries with viscosities above 3500 mPa s at a casting shear rate of 3.3 s -1...... of developing this graded ceramic tape casting was applications of these specific magnetocaloric properties within the magnetic refrigeration technology....

  19. Phthalocyanine doping to improve critical current densities in MgB2 tapes

    International Nuclear Information System (INIS)

    Zhang Xianping; Ma Yanwei; Wang Dongliang; Gao Zhaoshun; Wang Lei; Qi Yanpeng; Awaji, Satoshi; Watanabe, Kazuo; Mossang, Eric

    2009-01-01

    Phthalocyanine-doped MgB 2 tapes were prepared by the in situ powder-in-tube method. The relationships between the critical current properties, crystallinity and microstructure were studied as a function of the phthalocyanine doping level. It is found that both H irr and H c2 were improved when MgB 2 samples were doped with phthalocyanine, which are mainly attributed to the effective carbon substitution and enhanced flux pinning strength caused by very fine grain sizes. Furthermore, compared to pure samples, the MgO content remained almost unchanged in all doped tapes, which is very beneficial to having better grain connectivity in MgB 2 . Significantly improved J c was obtained in the phthalocyanine-doped MgB 2 tapes, especially under high magnetic fields.

  20. AC magnetic losses in Bi-2223/Ag tapes with different aspect ratios

    Energy Technology Data Exchange (ETDEWEB)

    Fang, J.; Luo, X.M.; Chen, D.X.; Collings, E.W.; Lee, E.; Sumption, M.D.; Alamgir, A.K.M.; Yi, H.P.; Fang, J.G.; Gu, C.; Guo, S.Q.; Liu, M.L.; Xin, Y.; Han, Z

    2004-10-01

    AC losses in multi-filamentary tapes depend on various parameters. Among them, the overall tape width and thickness are expected to have an important influence. In order to study this geometrical effect, five Bi-2223/Ag tapes with different aspect ratios from 5 to 26 have been prepared. AC losses have been measured at 77 K when a perpendicular AC magnetic field is applied. It has been found that at any frequencies the magnetic loss per cycle increases as the aspect ratio increases. For AC magnetic loss, with increasing frequency from 3 to 9000 Hz the losses as a function of frequency show a maximum if the field amplitude is much less than the full penetration field or increase continuously if the field amplitude is larger.

  1. AC magnetic losses in Bi-2223/Ag tapes with different aspect ratios

    International Nuclear Information System (INIS)

    Fang, J.; Luo, X.M.; Chen, D.X.; Collings, E.W.; Lee, E.; Sumption, M.D.; Alamgir, A.K.M.; Yi, H.P.; Fang, J.G.; Gu, C.; Guo, S.Q.; Liu, M.L.; Xin, Y.; Han, Z.

    2004-01-01

    AC losses in multi-filamentary tapes depend on various parameters. Among them, the overall tape width and thickness are expected to have an important influence. In order to study this geometrical effect, five Bi-2223/Ag tapes with different aspect ratios from 5 to 26 have been prepared. AC losses have been measured at 77 K when a perpendicular AC magnetic field is applied. It has been found that at any frequencies the magnetic loss per cycle increases as the aspect ratio increases. For AC magnetic loss, with increasing frequency from 3 to 9000 Hz the losses as a function of frequency show a maximum if the field amplitude is much less than the full penetration field or increase continuously if the field amplitude is larger

  2. Prototype high-speed tape target transport for a laser plasma soft-x-ray projection lithography source

    International Nuclear Information System (INIS)

    Haney, S.J.; Berger, K.W.; Kubiak, G.D.; Rockett, P.D.; Hunter, J.

    1993-01-01

    A prototype high-speed tape target transport is constructed for use in a high-repetition-rate laser plasma source. To reduce plasma debris, a 1000--5000-A-thick film of target material is supported by thin Mylar tape backing. Tape is transported to the laser focal volume at a maximum velocity of 356 cm/s, a rate sufficient to accommodate laser repetition rates of 1 kHz. The transport is fully vacuum compatible and can be retracted and then isolated from the laser plasma vacuum enclosure during tape reel replacement. The operating characteristics of the transport are described

  3. LANDSAT-D data format control book. Volume 6, appendix G: GSFC HDT-AM inventory tape (GHIT-AM)

    Science.gov (United States)

    1981-01-01

    The data format specifications of the Goddard HDT inventory tapes (GHITS), which accompany shipments of archival digital multispectral scanner image data (HDT-AM tapes), are defined. The GHIT is a nine-track, 1600-BPI tape which conforms to the ANSI standard and serves as an inventory and description of the image data included in the shipment. The archival MSS tapes (HDT-AMs) contain radiometrically corrected but geometrically uncorrected image data plus certain ancillary data necessary to perform the geometric corrections.

  4. Information Architecture in Library and Information Science Curricula.

    Science.gov (United States)

    Robins, David

    2002-01-01

    Discusses how information architecture is being handled in some library and information science (LIS) programs and suggests mappings between traditional LIS curricula and the marketplace for information architects. Topics include terminology used in LIS curricula; current job opportunities; and projections for the future. (LRW)

  5. Pricing Models and Payment Schemes for Library Collections.

    Science.gov (United States)

    Stern, David

    2002-01-01

    Discusses new pricing and payment options for libraries in light of online products. Topics include alternative cost models rather than traditional subscriptions; use-based pricing; changes in scholarly communication due to information technology; methods to determine appropriate charges for different organizations; consortial plans; funding; and…

  6. Snakes or Ladders? Evaluating a LibGuides pilot at University College Dublin Library

    OpenAIRE

    Dalton, Michelle; Pan, Rosalind

    2014-01-01

    Online subject guides are commonly used by libraries to provide information support to students. LibGuides (a cloud-based commercial product launched in 2007) represent one of the latest incarnations of the traditional subject guide or portal, and are widely used across American academic libraries. In Ireland however, library subject guides of entirely local design and hosted on a local web server still dominate. This paper outlines the project management process involved in implementing a Li...

  7. The effectiveness of Kinesio Taping on pain and disability in cervical myofascial pain syndrome.

    Science.gov (United States)

    Ay, Saime; Konak, Hatice Ecem; Evcik, Deniz; Kibar, Sibel

    The aim of this study was to investigate the effectiveness of Kinesio Taping and sham Kinesio Taping on pain, pressure pain threshold, cervical range of motion, and disability in cervical myofascial pain syndrome patients (MPS). This study was designed as a randomized, double-blind placebo controlled study. Sixty-one patients with MPS were randomly assigned into two groups. Group 1 (n=31) was treated with Kinesio Taping and group 2 (n=30) was treated sham taping five times by intervals of 3 days for 15 days. Additionally, all patients were given neck exercise program. Patients were evaluated according to pain, pressure pain threshold, cervical range of motion and disability. Pain was assessed by using Visual Analog Scale, pressure pain threshold was measured by using an algometer, and active cervical range of motion was measured by using goniometry. Disability was assessed with the neck pain disability index disability. Measurements were taken before and after the treatment. At the end of the therapy, there were statistically significant improvements on pain, pressure pain threshold, cervical range of motion, and disability (pdisability (p>0.05). This study shows that Kinesio Taping leads to improvements on pain, pressure pain threshold and cervical range of motion, but not disability in short time. Therefore, Kinesio Taping can be used as an alternative therapy method in the treatment of patients with MPS. Copyright © 2016 Elsevier Editora Ltda. All rights reserved.

  8. Does taping in addition to physiotherapy improve the outcomes in subacromial impingement syndrome? A systematic review.

    Science.gov (United States)

    Saracoglu, Ismail; Emuk, Yusuf; Taspinar, Ferruh

    2018-04-01

    Taping is used with or without other interventions for many purposes, especially to manage pain and improve functional activity in patients with shoulder pain. The aim of this review was to determine whether any taping technique in addition to physiotherapy care is more effective than physiotherapy care alone in patients with shoulder impingement syndrome. A systematic search of Cochrane Database of Systematic Review, MEDLINE (EBSCO), Physiotherapy Evidence Database (PEDro), CINAHL (EBSCO), PUBMED, AMED, EMBASE (OVID), The Kinesio Kinesio® Taping Method, Kinesio® Tex Tape UK and International websites ( www.kinesiotaping.co.uk ; www.kinesiotaping.com ) was conducted to June 2015. The outcome measures were pain, disability, range of motion and muscle strength. As data were not suitable for meta-analysis, narrative synthesis were applied. Three randomized controlled trials and one controlled trial (135 patients) were included. The results were conflicting and weak on the effectiveness of taping as an adjunct therapy for improvement of pain, disability, range of motion and muscle strength. Clinical taping in addition to physiotherapy interventions (e.g. exercise, electrotherapy, and manual therapy) might be an optional modality for managing patients with shoulder impingement syndrome, especially for the initial stage of the treatment; however, we need further robust, placebo controlled and consistent studies to prove whether it is more effective than physiotherapy interventions without taping.

  9. Magnetic field profiles of NbTi tapes

    International Nuclear Information System (INIS)

    Migliori, A.; Taylor, R.D.; Bartlett, R.D.

    1976-01-01

    Magnetic field profile measurements were performed on stabilized NbTi tapes in zero applied field carrying large transport current densities. Field profile data were taken on large diameter superconducting sample loops at temperatures between 2 0 K and T/sub c/ (about 9.2 0 K) and several persistent currents up to I/sub c/(T), the maximum. The field profiles scaled with current, independent of temperature, at temperatures below 8.5 0 K and were well described by an elliptical shell approximation which left a current-free, field-free central region. Critical state models applied to this self-field situation proved inadequate. Complex profiles produced by trapped flux in the tape loop were described quantitatively by assuming concentric elliptical shells each with a different current density. The maximum current which could be persisted in the loop at each temperature was linear from 4 to 8.5 K. The effective resistance of the superconducting loop including its joint was less than 10 -13 ohms

  10. Nonlinear Model of Tape Wound Core Transformers

    Directory of Open Access Journals (Sweden)

    A. Vahedi

    2015-03-01

    Full Text Available Recently, tape wound cores due to their excellent magnetic properties, are widely used in different types of transformers. Performance prediction of these transformers needs an accurate model with ability to determine flux distribution within the core and magnetic loss. Spiral structure of tape wound cores affects the flux distribution and always cause complication of analysis. In this paper, a model based on reluctance networks method is presented for analysis of magnetic flux in wound cores. Using this model, distribution of longitudinal and transverse fluxes within the core can be determined. To consider the nonlinearity of the core, a dynamic hysteresis model is included in the presented model. Having flux density in different points of the core, magnetic losses can be calculated. To evaluate the validity of the model, results are compared with 2-D FEM simulations. In addition, a transformer designed for series-resonant converter and simulation results are compared with experimental measurements. Comparisons show accuracy of the model besides simplicity and fast convergence

  11. Artificial Intelligence Controls Tape-Recording Sequence

    Science.gov (United States)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  12. History and operation of INIS magnetic tape retrieval service in CSSR

    International Nuclear Information System (INIS)

    Blazek, J.

    The Nuclear Information Centre is responsible for the utilization of the INIS magnetic tape in Czechoslovakia as the country's national INIS centre. The tape has been used since 1974 for selective dissemination of information using an EC 1040 computer. Currently, users are provided with SDI searches, their copies (the so-called parasite searches) and retrospective searches. The organization of INIS-SDI services is described and the results are reported of the poll among the users of the services. (Ha)

  13. Analysis of transient state in HTS tapes under ripple DC load current

    Science.gov (United States)

    Stepien, M.; Grzesik, B.

    2014-05-01

    The paper concerns the analysis of transient state (quench transition) in HTS tapes loaded with the current having DC component together with a ripple component. Two shapes of the ripple were taken into account: sinusoidal and triangular. Very often HTS tape connected to a power electronic current supply (i.e. superconducting coil for SMES) that delivers DC current with ripples and it needs to be examined under such conditions. Additionally, measurements of electrical (and thermal) parameters under such ripple excitation is useful to tape characterization in broad range of load currents. The results presented in the paper were obtained using test bench which contains programmable DC supply and National Instruments data acquisition system. Voltage drops and load currents were measured vs. time. Analysis of measured parameters as a function of the current was used to tape description with quench dynamics taken into account. Results of measurements were also used to comparison with the results of numerical modelling based on FEM. Presented provisional results show possibility to use results of measurements in transient state to prepare inverse models of superconductors and their detailed numerical modelling.

  14. The evolution of the tape measure protein: units, duplications and losses

    Directory of Open Access Journals (Sweden)

    Poisson Guylaine

    2011-10-01

    Full Text Available Abstract Background A large family of viruses that infect bacteria, called phages, is characterized by long tails used to inject DNA into their victims' cells. The tape measure protein got its name because the length of the corresponding gene is proportional to the length of the phage's tail: a fact shown by actually copying or splicing out parts of DNA in exemplar species. A natural question is whether there exist units for these tape measures, and if different tape measures have different units and lengths. Such units would allow us to retrace the evolution of tape measure proteins using their duplication/loss history. The vast number of sequenced phages genomes allows us to attack this problem with a comparative genomics approach. Results Here we describe a subset of phages whose tape measure proteins contain variable numbers of an 11 amino acids sequence repeat, aligned with sequence similarity, structural properties, and simple arithmetics. This subset provides a unique opportunity for the combinatorial study of phage evolution, without the added uncertainties of multiple alignments, which are trivial in this case, or of protein functions, that are well established. We give a heuristic that reconstructs the duplication history of these sequences, using divergent strains to discriminate between mutations that occurred before and after speciation, or lineage divergence. The heuristic is based on an efficient algorithm that gives an exhaustive enumeration of all possible parsimonious reconstructions of the duplication/speciation history of a single nucleotide. Finally, we present a method that allows, when possible, to discriminate between duplication and loss events. Conclusions Establishing the evolutionary history of viruses is difficult, in part due to extensive recombinations and gene transfers, and high mutation rates that often erase detectable similarity between homologous genes. In this paper, we introduce new tools to address this

  15. Simulation of YBCO Tape and Coils in HTS Maglev System

    Directory of Open Access Journals (Sweden)

    Song Mengxiao

    2017-01-01

    Full Text Available In the process of running high temperature superconducting maglev train, the AC(Alternating Current loss of superconducting coil is directly related to its safe operation and operating cost. In this paper, the simulation model was built based on the finite element software COMSOL Multiphysics, and mainly simulated and calculated the AC losses of YBCO(Yttrium Barium Copper Oxide tape and coils. In this model, as the solving object, the singular and infinite long YBCO tape and coils model was solved with H-formulation and the nonlinear characteristic (E-J constitutive law and anisotrophy (B-J characteristic were taken into consideration as the theoretical foundation. Then on the basis of the model under maglev suspension system, AC losses under different amplitude and frequence AC currents were calculated. The results shows that under different frequencies and dynamic components, the local maximum AC loss of YBCO tape and coils occurs when the steady-state DC(Direct Current current is 30A. Then comparing with old maglev suspension system, the new system can greatly reduce the energy consumption and the material cost.

  16. The design of the high energy physics massive data migration system

    International Nuclear Information System (INIS)

    Shi Jingyan; Zang Dongsong; Cheng Yaodong

    2010-01-01

    High energy physics is the typical data massive computing application due to its huge experiment data. For example, the amount of BESⅢ experiment data reaches to 4PB. Hierarchical storage system is adapted for the application in which disk array and tape library are used. It is quite important to migrate massive data from disk array to tape library. The article introduces the design and realization for the high performance data migration system between disk array and tape library. Besides, the system provides web page as the friendly user interface. (authors)

  17. Critical Current Properties of HTS Twisted Stacked-Tape Cable in Subcooled- and Pressurized-Liquid Nitrogen

    International Nuclear Information System (INIS)

    Tomita, M; Suzuki, K; Fukumoto, Y; Ishihara, A; Akasaka, T; Kobayashi, Y; Maeda, A; Takayasu, M

    2015-01-01

    A 2 m length Twisted Stacked-Tape Cable (TSTC) conductor which was fabricated by 32-YBCO-tapes (4 mm width) with a 200 mm twist pitch was investigated at various temperatures near 77 K in subcooled- and pressurized-liquid nitrogen. The critical current of the TSTC cable which was 1.45 kA at 77 K measured from 64 K to 85 K by controlling the equilibrium vapor pressure of nitrogen bath and were varied from 3.65 kA at 64 K to 0.42 kA at 85 K. The temperature dependence of cables’ critical current agrees with that of the 4 mm width YBCO tape. These results are encouraging for applications of a compact Twisted Stacked-Tape Cable application in railway systems. (paper)

  18. Fabrication and Characterization of Graded Anodes for Anode-Supported Solid Oxide Fuel Cells by Tape Casting and Lamination

    DEFF Research Database (Denmark)

    Beltran-Lopez, J.F.; Laguna-Bercero, M.A.; Gurauskis, Jonas

    2014-01-01

    Graded anodes for anode-supported solid oxide fuel cells (SOFCs) are fabricated by tape casting and subsequent cold lamination of plates using different compositions. Rheological parameters are adjusted to obtain stable suspensions for tape casting. The conditions for the tape casting and laminat......Graded anodes for anode-supported solid oxide fuel cells (SOFCs) are fabricated by tape casting and subsequent cold lamination of plates using different compositions. Rheological parameters are adjusted to obtain stable suspensions for tape casting. The conditions for the tape casting...... and lamination will be described. Flexural strength of the reduced cermets measured using three-point bending configuration is 468±37MPa. The graded anode supports are characterized by scanning electron microscope observations, mercury porosimetry intrusion, and resistivity measurements, showing an adequate...... of tapes at room temperature without using plasticizers. This is made by the combination of two different binders with varying Tg (glass transition temperature) which resulted in plastic deformation at room temperature. Those results indicate that the proposed process is a cost-effective method...

  19. Study of the inhomogeneity of critical current under in-situ tensile stress for YBCO tape

    Science.gov (United States)

    Zhu, Y. P.; Chen, W.; Zhang, H. Y.; Liu, L. Y.; Pan, X. F.; Yang, X. S.; Zhao, Y.

    2018-07-01

    A Hall sensor system was used to measure the local critical current of YBCO tape with high spatial resolution under in-situ tensile stress. The hot spot generation and minimum quench energy of YBCO tape, which depended on the local critical current, was calculated through the thermoelectric coupling model. With the increase in tensile stress, the cracks which have different dimensions and critical current degradation arose more frequently and lowered the thermal stability of the YBCO tape.

  20. Field mapping measurements to determine spatial and field dependence of critical current density in YBCO tapes

    International Nuclear Information System (INIS)

    Leclerc, J.; Berger, K.; Douine, B.; Lévêque, J.

    2013-01-01

    Highlights: • A method for characterizing superconducting tapes from field mapping is presented. • A new and efficient field mapping apparatus has been setup. • This method allows the spatial characterization of superconducting tapes. • The critical current density is obtained as a function of the flux density. • This method has been experimentally tested on an YBCO tape. -- Abstract: In this paper a measurement method that allows the determination of the critical current density of superconducting tape from field mapping measurements is presented. This contact-free method allows obtaining characteristics of the superconductor as a function of the position and of the applied flux density. With some modifications, this technique can be used for reel-to-reel measurements. The determination of the critical current density is based on an inverse calculation. This involves calculating the current distribution in the tape from magnetic measurements. An YBaCuO tape has been characterized at 77 K. A defect in this superconductor has been identified. Various tests were carried out to check the efficiency of the method. The inverse calculation was tested theoretically and experimentally. Comparison with a transport current measurement was also performed

  1. Chronic vaginal discharge and left leg edema after a transobturator tape procedure.

    Science.gov (United States)

    Kim, Tae-Hee; Lee, Hae-Hyeog; Kim, Jun-Mo

    2014-05-01

    We report on a patient who underwent total vaginal hysterectomy for urinary incontinence 8 years previously with a sling operation using transobturator tape (TOT). She was admitted to our hospital after complaints of vaginal discharge, foul odor, and bleeding, left thigh pain, and edema. Magnetic resonance imaging (MRI) and computed tomography (CT) revealed a fistula tract from the vagina or urethra with remnant sling tape. We removed the remnant tape using intraoperative ultrasonography. This case exemplifies the rare occurrence of a vaginal fistula extending to the obturator, adductor, and pectineus muscles combined with myositis after TOT placement. It is important that urogynecologists recognize that TOT procedures may result in complications accompanied by common recurrent vaginal symptoms, such as vaginal odor and spotting, which can be identified by MRI or CT.

  2. Test results of fault current limiter using YBCO tapes with shunt protection

    Energy Technology Data Exchange (ETDEWEB)

    Baldan, Carlos A; Lamas, Jerika S; Shigue, Carlos Y [Escola de Engenharia de Lorena, EEL USP, Lorena - SP (Brazil); Filho, Ernesto Ruppert, E-mail: cabaldan@gmail.co [Faculdade de Engenharia Eletrica, FEEC Unicamp, Campinas - SP (Brazil)

    2010-06-01

    A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper.

  3. Evaluating a Chat Reference Service at the University of South Alabama's Baugh Biomedical Library

    Science.gov (United States)

    Clanton, Clista C.; Staggs, Geneva B.; Williams, Thomas L.

    2006-01-01

    The University of South Alabama's Baugh Biomedical Library recently initiated a chat reference service targeted at distance education students in the biomedical sciences. After one year of service, the library conducted an evaluation of the chat reference to assess the success of this mode of reference service. Both traditional reference and…

  4. Saskatchewan Residents’ Use of The Cochrane Library

    Directory of Open Access Journals (Sweden)

    Dorothy Anne Forbes

    2007-11-01

    Full Text Available There is strong evidence of failure to translate research findings into the health care decision-making process of consumers, practitioners and policy makers (Grimshaw, 2007. Recognizing that The Cochrane Database of Systematic Reviews contained in The Cochrane Library (the Library are the “gold standard” of systematic reviews, Saskatchewan’s Health Quality Council provided funding for a provincial license and an evaluation study. In July 2004, Saskatchewan became the first province in Canada to provide all residents with access to the Library. The primary aim of the study was to enhance and evaluate the use of the Library over three years. Since September 2004, over 46 training sessions have been conducted on searching the Library online databases. Attendees at the workshops were informed of the evaluation study and invited to participate. Those who consented to participate were telephoned following the workshops and audio-taped interviews were conducted. Usage of the Library was also tracked using data available from Wiley InterScience. Three month (n=94, six month (n=71, nine month (n=79, and 12 month (n=72 telephone interviews were conducted. Most participants were librarians (n=31.5%, followed by nurses (16.3%, therapists (7.6%, library support staff (5.4%, pharmacists (4.3%, physicians (3.3%, and others (30.5. Most were between 40 to 65 years of age (71.6% and female (92.4%. Most respondents had accessed the Library at the three-month (65.2% and six-month (64.2% follow-up interviews. However, this percent fell to 45.2% at the nine-month and 27.4% at the twelve-month interview. MeSH searches were more frequent than standard keyword searches and HTML full text retrievals were more common than PDF versions. It is assumed that HTML versions were scanned for particular information whereas PDF versions were selected when the person wished to save and read the whole review. Librarians, practitioners and consumers are more likely to be

  5. NdFeB thick films prepared by tape casting

    International Nuclear Information System (INIS)

    Pawlowski, B.; Schwarzer, S.; Rahmig, A.; Toepfer, J.

    2003-01-01

    NdFeB films of thickness between 100 and 800 μm were prepared by tape casting of a slurry containing 84-95 wt% of commercial NdFeB powder (MQP-B, -Q and -S). After curing the flexible green tapes at 120 deg. C non-porous magnetic films are obtained. The remanence of the films is in the range of 350-450 mT and the coercivity is between 300 and 800 kA/m depending on the type of MQP powder used. The magnetic properties of the films are discussed in relation to film composition and type of magnetic material. For MEMS applications the thick films are magnetized with a multi-pole stripe pattern with 1 mm pole pitch. The induction at the surface of the films was measured with a Hall probe and compared to theoretical calculations. The results indicate that the films are completely magnetized regardless of the film thickness. Tape-casted NdFeB thick films are promising candidates for applications in micro-systems or actuators. Miniaturization of the magnet components is one of the key issues in the development of electromagnetic micro-systems, thus creating a need for replacement of small sintered magnets by magnetic thick film components. Other applications include encoders

  6. About the Library - Betty Petersen Memorial Library

    Science.gov (United States)

    branch library of the NOAA Central Library. The library serves the NOAA Science Center in Camp Springs , Maryland. History and Mission: Betty Petersen Memorial Library began as a reading room in the NOAA Science Science Center staff and advises the library on all aspects of the library program. Library Newsletters

  7. Development of Bi-based high critical current density superconducting tapes

    International Nuclear Information System (INIS)

    Swaminathan, G.

    1995-01-01

    In order to achieve the aim of developing suitable superconducting materials the main emphasis has to be made in the following areas viz., synthesizing powders, detailed study of sintering and phase conversion process in relation to the critical current density (J c ) on pellets and optimising of tape processing parameters. The bismuth system has been found to be more favourable for making wires and tapes because of its high transition temperature, good stability, does not require oxygen on cooling and is non-toxic. These have been the most convenient properties which made the BiSCO material the most popular one

  8. The new CERN tape software - getting ready for total performance

    CERN Document Server

    Cano, E; Kruse, D F; Kotlyar, V; Côme, D

    2015-01-01

    CASTOR (the CERN Advanced STORage system) is used to store the custodial copy of all of the physics data collected from the CERN experiments, both past and present. CASTOR is a hierarchical storage management system that has a disk-based front-end and a tape-based back-end. The software responsible for controlling the tape back-end has been redesigned and redeveloped over the last year and was put in production at the beginning of 2015. This paper summarises the motives behind the redesign, describes in detail the redevelopment work and concludes with the short and long-term benefits.

  9. Delayed latency of peroneal reflex to sudden inversion with ankle taping or bracing.

    Science.gov (United States)

    Shima, N; Maeda, A; Hirohashi, K

    2005-01-01

    The purpose of the present study was to examine the effects of ankle taping and bracing based on the peroneal reflex in the hypermobile and normal ankle joints with and without history of ankle injury. Thirty-six ankle joints of 18 collegiate American football athletes with and without previous history of injury were studied. The angle of talar tilt (TT) was measured by stress radiograph for classifying normal (TT5 degrees ) ankles. They were tested with taping, bracing, and without any supports as a control. The latency of peroneus longus muscle was measured by a sudden inversion of 25 degrees using surface EMG signals. The results of the present study show no significant three-way Group (hypermobile or normal ankles) by History (previously injured or uninjured ankles) by Condition (control, taping, or bracing) interaction, while Condition main effect was significant (p0.05). In conclusion, ankle taping and bracing delayed the peroneal reflex latency not only for hypermobile ankles and/or injured ankle joints but also for intact ankle joints.

  10. Of data and dust

    CERN Multimedia

    Stephanie Hills

    2016-01-01

    The traditional image of an archive is one of dusty old boxes, books and papers. When your archive is digital, dust spells disaster. An innovative environmental sensor designed and built by a CERN IT specialist has become an essential element in the Laboratory’s data-preservation strategy.   The novel air particle monitoring sensor designed by CERN's Julien Leduc. CERN’s archive holds more than 130 petabytes of data from past and present high-energy physics experiments. Some of it is 40 years old, most of it needs to be kept forever, and all of it is held on tape cartridges (over 20,000 of them). The cartridges are held inside tape libraries with robotic arms that load them into tape drives where they can be read and written. Tape cartridges have many advantages over other data storage media, notably cost and long-term reliability, but topping the list of drawbacks is their vulnerability to contamination from airborne dust particles; a tiny piece of g...

  11. Distanced Data: Transcribing Other People's Research Tapes

    Science.gov (United States)

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  12. Localized leak detection utilizing moisture sensitive tape

    International Nuclear Information System (INIS)

    Riddle, P.

    1984-01-01

    Moisture sensitive tape (MST) has been used in various nuclear power plants to detect leaks in reactor piping systems. The sensor assembly consists of MST, transponder, and sensor carrier, and is installed on the exterior of thermal insulation. The components, applications, installation, and purchasing information are discussed in the paper

  13. Conventional Tape versus Kinesiotape for Hallux Valgus Correction

    Directory of Open Access Journals (Sweden)

    Nadia Lotfy Radwan

    2017-01-01

    Full Text Available This study was commenced to compare the effect of Kinesiotape (KT versus conventional tape (CT on HVA and IMA as well as the intensity of pain from HV deformity. Methodology: Female patients with age 45 to 60 years and diagnosed with mild to moderate HV were included in the study. The foot pain intensity was assessed by visual analogue scale (VAS before applying tape and after completion of the study. Results: The outcome measures of pain intensity showed a non-significant difference between both groups before intervention (p>0.05. Within both KT and CT groups, the pre-and post-treatment scores were significantly different (p˂0.05. In the comparison of the post treatment scores, there was a significant difference (p˂0.05 between both groups favouring the KT group..

  14. America's Star Libraries, 2010: Top-Rated Libraries

    Science.gov (United States)

    Lyons, Ray; Lance, Keith Curry

    2010-01-01

    The "LJ" Index of Public Library Service 2010, "Library Journal"'s national rating of public libraries, identifies 258 "star" libraries. Created by Ray Lyons and Keith Curry Lance, and based on 2008 data from the IMLS, it rates 7,407 public libraries. The top libraries in each group get five, four, or three stars. All included libraries, stars or…

  15. An assessment of collections at the University of Wisconsin-Madison Health Sciences Libraries: drug resistance.

    Science.gov (United States)

    Bergen, P L; Nemec, D

    1999-01-01

    In December 1997, the authors completed an in-depth collection assessment project at the University of Wisconsin-Madison Health Sciences Libraries. The purpose was to develop a framework for future collection assessment projects by completing a multifaceted evaluation of the libraries' monograph and serial collections in the subject area of drug resistance. Evaluators adapted and synthesized several traditional collection assessment tools, including shelflist measurement, bibliography and standard list checking, and citation analysis. Throughout the project, evaluators explored strategies to overcome some of the problems inherent in the application of traditional collection assessment methods to the evaluation of biomedical collections. Their efforts resulted in the identification of standard monographs and core journals for the subject area, a measurement of the collections' strength relative to the collections of benchmark libraries, and a foundation for future collection development within the subject area. The project's primary outcome was a collection assessment methodology that has potential application to both internal and cooperative collection development in medical, pharmaceutical, and other health sciences libraries.

  16. Effect of crystallization rate of initial alloy on magnetic properties of amorphous tape

    International Nuclear Information System (INIS)

    Roshchin, V.E.; Gribanov, V.P.; Shcherbakov, D.G.; Gun'kin, V.E.

    1994-01-01

    An investigation is made into mechanism and character of cooling rate effect when castings crytallizing on magnetic properties of rapidly quenched amorphous tape of Fe 78 B 12 Si 9 Ni 1 alloy. The increase of cooling rate and holding at heat for superheated melt is shown to result in a rise of Curie point of amorphous tape

  17. 10 years of 1:1 taping in Belgium - A selection of murder cases involving fibre examination.

    Science.gov (United States)

    De Wael, K; Lepot, L; Lunstroot, K; Gason, F

    2016-01-01

    Since 2002, the 1:1 tape lifting technique on murder victims has been introduced in Belgium. Thirty-six murder cases for which a fibre examination was carried out in our laboratory between 2002 and 2012 are reviewed. These cases all involved the collection of microtraces on 39 victims using a 1:1 taping or similar technique, called semi 1:1 taping. The degree of "positive outcomes" for investigative and comparative fibre cases is high. Especially in cases where the modus operandi of suspects had to be verified, the examination of the 1:1 tape lifting led to very useful fibre results. The findings from some of these fibre cases are used to illustrate the advantages, drawbacks and points of interest of the two collection techniques. These are also compared with the zonal taping technique, another microtrace collection technique applied on victims at the crime scene. Copyright © 2015 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  18. Effects of two different knee tape procedures on lower-limb kinematics and kinetics in recreational runners.

    Science.gov (United States)

    Howe, A; Campbell, A; Ng, L; Hall, T; Hopper, D

    2015-08-01

    The purpose of this study was to compare the effects of Mulligan's tape (MT) and kinesio tape (KT) with no tape (NT) on hip and knee kinematics and kinetics during running. Twenty-nine female recreational runners performed a series of 'run-throughs' along a 10-m runway under the three taping conditions. Two force plates and a 14-camera Vicon motion analysis system (Oxford Metrics, Inc., Oxford, UK) captured kinematic and kinetic data for each dependent variable from ground contact to toe off. Comparisons of each dependent variable under three taping conditions were assessed through Statistical Package for the Social Sciences (SPSS; SPSS, Inc., Chicago, Illinois, USA; P-value kinetics, between KT and NT (P = 1.000). MT appears to influence hip and knee biomechanics during running in an asymptomatic sample, whereas KT appeared to be biomechanically not different from NT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Featured Library: Parrish Library

    OpenAIRE

    Kirkwood, Hal P, Jr

    2015-01-01

    The Roland G. Parrish Library of Management & Economics is located within the Krannert School of Management at Purdue University. Between 2005 - 2007 work was completed on a white paper that focused on a student-centered vision for the Management & Economics Library. The next step was a massive collection reduction and a re-envisioning of both the services and space of the library. Thus began a 3 phase renovation from a 2 floor standard, collection-focused library into a single floor, 18,000s...

  20. A library treasure hunt – An alternative way to introduce new university students to the library

    Directory of Open Access Journals (Sweden)

    Kristina Holmin Verdozzi

    2013-12-01

    Full Text Available Introducing new students to the library and its resources during the first hectic weeks at university can pose a considerable challenge. We have to compete with many other kinds of introductory activities, making new friends, becoming acquainted with the subject, not to mention all the parties and social functions arranged for new students. The traditional lecture, or showing large groups of tired students around the library just wasn't working. So, a few years ago, we started to think about radical new ways of introducing students to the library. We hit upon the idea of arranging a treasure hunt. Students working in small groups have to carry out various tasks at different stations in different libraries. When each task has been successfully completed, a verbal report is made to the librarian at that library, and students can ask questions, before going on to the next task. By carrying out actual tasks, the students become familiar with the important aspects of library resources; learning by doing and having fun at the same time. The "treasure" at the end of the hunt was an apple, a sweet, a pencil, a small LED flashlight and information brochures about the library and the master programme in physics. One of the decisive factors in the success of this activity was the cooperation of lecturers, who integrated it into their introductory programme. It also had high status, as it was a compulsory activity, thanks to the commitment and understanding of lecturers. The treasure hunt is important in the students' later studies as they know which library resources are available, and they recognise the librarians. This lowers the threshold for the further development of the students' information gathering skills. The success of this activity in one of the subjects taught at the Department of Physics has led to the decision to make the library treasure hunt compulsory for all students at the Department, in both the Engineering Faculty and the Science

  1. Modern Library Facilities to Enhance Learning in a Teachers' College

    African Journals Online (AJOL)

    unique firstlady

    Modern facilities/Equipments in the library that can aid effective utilization of ... we acquire the education by imitation or learning through the process of “doing it .... spent while searching for materials compared to traditional services method.

  2. Effects of scapular taping on the activity onset of scapular muscles and the scapular kinematics in volleyball players with rotator cuff tendinopathy.

    Science.gov (United States)

    Leong, Hio Teng; Ng, Gabriel Yin-Fat; Fu, Siu Ngor

    2017-06-01

    To examine the effect of scapular taping on the activity onset of scapular muscles and the scapular kinematics during arm elevation in volleyball players with rotator cuff (RC) tendinopathy. Randomized placebo-controlled repeated measures METHODS: Twenty-six male volleyball players with RC tendinopathy (mean age=23.6±3.3years) participated in the study. Electromyography (EMG) activity onset of upper trapezius (UT), middle trapezius (MT), lower trapezius (LT) and serratus anterior (SA) and the three-dimensional scapular kinematics quantified by using an acromial marker cluster method were compared with three scapular taping protocols, namely, no taping, therapeutic taping, and placebo taping. The MT, LT and SA activated significantly earlier in both therapeutic taping (all p<0.005) and placebo taping conditions than no taping conditions (all p<0.002). There was a small increase in the scapular upward rotation when therapeutic taping and no taping conditions were compared (p=0.007). Scapular taping may enhance the neuromotor control of the scapular muscles. Whether it provides adequate support for normal scapular kinematics during arm movement in athletes with RC tendinopathy await for further studies. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  3. Influence of twisted tape turbulence promoter on fouling reduction in microfiltration of milk proteins

    Directory of Open Access Journals (Sweden)

    Popović Svetlana S.

    2011-01-01

    Full Text Available Membrane filtration has become one of the major technologies in the food industry. It is widely applied in the dairy industry, and it is mostly used for the concentration and fractionation of milk proteins and for the whey processing. Of all pressure driven membrane processes, ultrafiltration is the most widely used. The major disadvantage of pressure driven membrane processes is severe fouling of membrane during filtration particularly when the fluids containing proteins are processed. Fouling with proteins is complex phenomenon because it occurs at the membrane surface as well as in the pores of membrane, and depends on the operating conditions and on the interactions of proteins and membrane material. In order to reduce fouling of the membrane different techniques have been developed, and one of them relies on the changing of the hydrodynamic conditions in the membrane or module. In this study, influence of twisted tape turbulence promoters on the fouling reduction in cross-flow microfiltration of skim milk was investigated. Twisted tapes with tree characteristic ratios of helix element length to the tape diameter (aspect ratio were studied. It was shown that twisted tapes with different aspect ratios reduce fouling of membrane by a factor of three or more. The presence of twisted tape induces changes in the flow patterns from straight to helicoidally thus producing turbulence flow at the lower cross-flow rates. Turbulence intensification prevents accumulation of proteins at membrane surface enabling reduction in reversible fouling what results in the reduction of overall membrane fouling. The best performance was achieved using a twisted tape with the lowest aspect ratio of 1.0. This promoter reduces fouling seven times at low transmembrane pressure and low cross-flow velocity. The twisted tape with aspect ratio 1.0 induces the most intensive turbulence, the longest helicoidal flow path, and appearance of vortices near the membrane surfaces

  4. Efek Interaksi Ragi Tape dan Ragi Roti terhadap Kadar Bioetanol Ketela Pohon (Manihot Utilissima, Pohl Varietas Mukibat

    Directory of Open Access Journals (Sweden)

    Tri Budi Kurniawan

    2014-09-01

    Full Text Available Ketela pohon (Manihot utilissima, Pohl varietas mukibat berpotensi sebagai bahan baku bioetanol. Penelitian bertujuan untuk mengetahui efek interaksi ragi tape dan ragi roti terhadap kadar bioetanol ketela pohon mukibat dan menentukan interaksi terendah yang efektif menghasilkan bioetanol yang dapat terbakar. Sampel yang digunakan adalah ketela pohon mukibat umur 7 bulan dengan berat rata-rata 500 gram. Penelitian menggunakan Rancangan Acak Lengkap pola faktorial, yaitu konsentrasi ragi tape (0%, 0,3%, 0,6% dan 0,9% dan konsentrasi ragi roti (0%, 0,3%, 0,6% dan 0,9% dengan 3 kali ulangan. Parameter yang diukur meliputi jumlah sel khamir (data pendukung dan kadar bioetanol (data utama. Data kadar bioetanol yang diperoleh dianalisis menggunakan anava dua arah dan dilanjutkan uji Duncan (DMRT pada taraf kesalahan 5%. Hasil penelitian menunjukkan ada pengaruh interaksi ragi tape dan ragi roti terhadap kadar bioetanol ketela pohon mukibat p>0,05. Konsentrasi ragi tape dan ragi roti yang tinggi menghasilkan kadar bioetanol yang tinggi. Interaksi ragi tape 0,6% dan ragi roti 0,3% (T2R1 merupakan interaksi terendah yang efektif menghasilkan kadar bioetanol yang dapat terbakar (36%. Interaksi ragi tape 0,9% dan ragi roti 0,9% (T3R3 menghasilkan kadar bioetanol tertinggi dengan rata-rata mencapai 49,8%.Cassava (Manihot utilissima, Pohl var Mukibat is potential for bioethanol feedstock. The study aimed to determine the effects of the interaction of bread yeast and tape yeast on the concentration of mukibat cassava bioethanol and to determine the lowest effective interaction can produce flammable bioethanol. The samples used were mukibat cassava aged 7 months with an average weight of 500 grams. Research design was completely randomized design factorial, tape yeast concentration (0%, 0.3%, 0.6% and 0.9% and the concentration of yeast bread (0%, 0.3%, 0.6% and 0.9% with 3 replications. Parameters measured include the number of yeast cells (supporting data

  5. Multigroup cross section library; WIMS library

    International Nuclear Information System (INIS)

    Kannan, Umasankari

    2000-01-01

    The WIMS library has been extensively used in thermal reactor calculations. This multigroup constants library was originally developed from the UKNDL in the late 60's and has been updated in 1986. This library has been distributed with the WIMS-D code by NEA data bank. The references to WIMS library in literature are the 'old' which is the original as developed by the AEA Winfrith and the 'new' which is the current 1986 WIMS library. IAEA has organised a CRP where a new and fully updated WIMS library will soon be available. This paper gives an overview of the definitions of the group constants that go into any basic nuclear data library used for reactor calculations. This paper also outlines the contents of the WIMS library and some of its shortcomings

  6. Ceramic tape casting: A review of current methods and trends with emphasis on rheological behaviour and flow analysis

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Bulatova, Regina; Tok, A. I Y

    2016-01-01

    Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Today, tape casting is the basic fabrication process that provides multilayered capacitors and multilayered ceramic packages. In tape casti...

  7. "Hack" Is Not A Dirty Word--The Tenth Anniversary of Patron Access Microcomputer Centers in Libraries.

    Science.gov (United States)

    Dewey, Patrick R.

    1986-01-01

    The history of patron access microcomputers in libraries is described as carrying on a tradition that information and computer power should be shared. Questions that all types of libraries need to ask in planning microcomputer centers are considered and several model centers are described. (EM)

  8. Rapid profiling of the antigen regions recognized by serum antibodies using massively parallel sequencing of antigen-specific libraries.

    KAUST Repository

    Domina, Maria; Lanza Cariccio, Veronica; Benfatto, Salvatore; D'Aliberti, Deborah; Venza, Mario; Borgogni, Erica; Castellino, Flora; Biondo, Carmelo; D'Andrea, Daniel; Grassi, Luigi; Tramontano, Anna; Teti, Giuseppe; Felici, Franco; Beninati, Concetta

    2014-01-01

    There is a need for techniques capable of identifying the antigenic epitopes targeted by polyclonal antibody responses during deliberate or natural immunization. Although successful, traditional phage library screening is laborious and can map only some of the epitopes. To accelerate and improve epitope identification, we have employed massive sequencing of phage-displayed antigen-specific libraries using the Illumina MiSeq platform. This enabled us to precisely identify the regions of a model antigen, the meningococcal NadA virulence factor, targeted by serum antibodies in vaccinated individuals and to rank hundreds of antigenic fragments according to their immunoreactivity. We found that next generation sequencing can significantly empower the analysis of antigen-specific libraries by allowing simultaneous processing of dozens of library/serum combinations in less than two days, including the time required for antibody-mediated library selection. Moreover, compared with traditional plaque picking, the new technology (named Phage-based Representation OF Immuno-Ligand Epitope Repertoire or PROFILER) provides superior resolution in epitope identification. PROFILER seems ideally suited to streamline and guide rational antigen design, adjuvant selection, and quality control of newly produced vaccines. Furthermore, this method is also susceptible to find important applications in other fields covered by traditional quantitative serology.

  9. Rapid profiling of the antigen regions recognized by serum antibodies using massively parallel sequencing of antigen-specific libraries.

    Directory of Open Access Journals (Sweden)

    Maria Domina

    Full Text Available There is a need for techniques capable of identifying the antigenic epitopes targeted by polyclonal antibody responses during deliberate or natural immunization. Although successful, traditional phage library screening is laborious and can map only some of the epitopes. To accelerate and improve epitope identification, we have employed massive sequencing of phage-displayed antigen-specific libraries using the Illumina MiSeq platform. This enabled us to precisely identify the regions of a model antigen, the meningococcal NadA virulence factor, targeted by serum antibodies in vaccinated individuals and to rank hundreds of antigenic fragments according to their immunoreactivity. We found that next generation sequencing can significantly empower the analysis of antigen-specific libraries by allowing simultaneous processing of dozens of library/serum combinations in less than two days, including the time required for antibody-mediated library selection. Moreover, compared with traditional plaque picking, the new technology (named Phage-based Representation OF Immuno-Ligand Epitope Repertoire or PROFILER provides superior resolution in epitope identification. PROFILER seems ideally suited to streamline and guide rational antigen design, adjuvant selection, and quality control of newly produced vaccines. Furthermore, this method is also susceptible to find important applications in other fields covered by traditional quantitative serology.

  10. Rapid profiling of the antigen regions recognized by serum antibodies using massively parallel sequencing of antigen-specific libraries.

    KAUST Repository

    Domina, Maria

    2014-12-04

    There is a need for techniques capable of identifying the antigenic epitopes targeted by polyclonal antibody responses during deliberate or natural immunization. Although successful, traditional phage library screening is laborious and can map only some of the epitopes. To accelerate and improve epitope identification, we have employed massive sequencing of phage-displayed antigen-specific libraries using the Illumina MiSeq platform. This enabled us to precisely identify the regions of a model antigen, the meningococcal NadA virulence factor, targeted by serum antibodies in vaccinated individuals and to rank hundreds of antigenic fragments according to their immunoreactivity. We found that next generation sequencing can significantly empower the analysis of antigen-specific libraries by allowing simultaneous processing of dozens of library/serum combinations in less than two days, including the time required for antibody-mediated library selection. Moreover, compared with traditional plaque picking, the new technology (named Phage-based Representation OF Immuno-Ligand Epitope Repertoire or PROFILER) provides superior resolution in epitope identification. PROFILER seems ideally suited to streamline and guide rational antigen design, adjuvant selection, and quality control of newly produced vaccines. Furthermore, this method is also susceptible to find important applications in other fields covered by traditional quantitative serology.

  11. THE MID - TERM EFFECT OF KINESIO TAPING ON PEAK POWER OF QUADRICEPS AND HAMSTRING MUSCLES AFTER ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    Amel Khabazan Mahdi

    2017-01-01

    Full Text Available Purpose: The aim of this study was to assess mid- term effect of Kinesio tape on peak power of quadriceps and hamstrings muscles after ACL reconstruction 24 hours after taping. Material: Thirty six men who had undergone ACL reconstruction and completed physiotherapy periods (6 months were assigned to no taping, placebo and taping groups. Peak power was tested before and 24 hours after taping by Isokinetic dynamometry. Data was analyzed by SPSS software 19. ANOVA and post hoc test (LSD were used for interpretive analysis. Results: The results showed that the effect of Kinesio tape on peak power of quadriceps muscles at velocities of 180°/s and 300°/s was significant. In the hamstring muscles, significant effects were obtained at velocities of 60°/s, 180°/s & 300°/s. Conclusion: Positive impacts of Kinesio tape on muscular peak power among athletes who had ACL reconstruction were observed. Regardless of psychological effect and reducing re - injury fear, Kinesio - tape causes to stabilize and increase effective range of motion of the knee, so it is recommended that in the explosive training, athletes who have ACL reconstruction should use tape to reduce the probability of re-injury and increase muscle power.

  12. Simulation of transport critical current of Bi2223/Ag tape with ferromagnetic shielding

    International Nuclear Information System (INIS)

    Gu, C.; Alamgir, A.K.M.; Qu, T.M.; Han, Z.

    2008-01-01

    Ferromagnetic shielding (FS) was coated onto the surface of the Bi2223/Ag multi-filamentary tape. Transport critical current of the Bi2223/Ag multi-filamentary tape with a FS was systematically studied by numerical simulation. In the help of a finite element analysis (FEA) tool, we are able to understand how the FS alters the flux inside the superconductor region and thus increases and decreases the critical current density locally. The results show the open FS function both positively and negatively to the performance of the tape. An optimization process was proposed, aiming to reach a tradeoff between I c increasing and less usage of the ferromagnetic material. Three important shielding parameters, shielding width, shielding thickness, and shielding material were taken into account

  13. Simulation of transport critical current of Bi2223/Ag tape with ferromagnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)], E-mail: guchen@tsinghua.edu.cn; Alamgir, A.K.M. [Faculty of Engineering, Yokohama National University, 75-9 Tokiwadai, Hodogaya, ku, Yokohama (Japan); Qu, T.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory for Advanced Materials Processing Technology, Ministry of Education (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)

    2008-09-15

    Ferromagnetic shielding (FS) was coated onto the surface of the Bi2223/Ag multi-filamentary tape. Transport critical current of the Bi2223/Ag multi-filamentary tape with a FS was systematically studied by numerical simulation. In the help of a finite element analysis (FEA) tool, we are able to understand how the FS alters the flux inside the superconductor region and thus increases and decreases the critical current density locally. The results show the open FS function both positively and negatively to the performance of the tape. An optimization process was proposed, aiming to reach a tradeoff between I{sub c} increasing and less usage of the ferromagnetic material. Three important shielding parameters, shielding width, shielding thickness, and shielding material were taken into account.

  14. Use of Kinesio-Taping in the Management of Hallux Rigidus: A Case Report

    Directory of Open Access Journals (Sweden)

    Gul Oznur Karabicak

    2017-03-01

    Full Text Available Hallux rigidus is a progressive degenerative disease of the first metatarsophalangeal joint. It is characterized by pain, limitation of the metatarsophalangeal joint motion, mainly dorsiflexion, progressive osteophyte formation and functional impairment. Although there have been many studies concerning non-operative management of hallux rigidus, no research has yet examined the effects of kinesio-taping in hallux rigidus. We present a 57-year-old woman with pain and stiffness around the big toe while walking, and functional insufficiency. The patient received kinesio-taping combined with therapeutic exercise. Pain intensity, range of motion (ROM, functional status were used as the outcome measures. According to the results, kinesio-taping may help reduce pain, increase the range of motion and functional levels in patients with hallux rigidus.

  15. Cervical ectopic pregnancy: Mersilene tape in surgical management

    African Journals Online (AJOL)

    2 Division of Obstetrics and Gynaecology, Mediclinic Hospital, Nelspruit, Mpumalanga, South Africa. Corresponding author: A A ... case of cerv ical ectopic pregnancy that was managed using cervical cerclage with Mersilene tape as an interven tion to reduce intraoperative haemorrhage during evacuation. Case report.

  16. Trading Virtual Legacies (Management of Tradition from Alexandria to Internet)

    NARCIS (Netherlands)

    S.J. Magala (Slawomir)

    2000-01-01

    textabstractWill the reconstructed library of Alexandria prevent a forthcoming clash of civilizations? Inventing and re-inventing traditions requires total quality management and multiple networking in shifting alliances in the information space. Stock exchange of cultural forms has long abandoned

  17. Formation of oiliness and sebum output--comparison of a lipid-absorbant and occlusive-tape method with photometry.

    Science.gov (United States)

    Serup, J

    1991-07-01

    Sebum output and the development of oiliness formation were studied in 24 acne-prone volunteers. Sebutape and photometric measurement by the Sebumeter were compared. Tapes were taken 1, 2 and 3 h after degreasing. Tapes were scored, and light transmission was measured by a special densitometric device. Sebumeter recordings were performed after 3 h. Densitometric evaluation of tapes was accurate with a high correlation to scoring. Sebutape and Sebumeter assessments correlated. However, in some individuals the tape method overestimated the sebum output. Right-left comparison indicated that the tape method was less reproducible, particularly after longer sampling periods. It is suggested that Sebutape, due to water occlusion and temperature insulation during the sampling period, interferes with sebum droplet formation and spreading. However, such systematic interference may be advantageous since sweating and heat are important clinical prerequisites in the formation of oiliness. Thus, it is suggested that the Sebutape is a specialized method for the determination of 'oiliness', the very last phase of sebum output, in which sebum droplets spread over the skin surface. The tape is not automatically comparable to other methods for determining sebum output from the follicular reservoir.

  18. Kinesthetic taping improves walking function in patients with stroke: a pilot cohort study.

    Science.gov (United States)

    Boeskov, Birgitte; Carver, Line Tornehøj; von Essen-Leise, Anders; Henriksen, Marius

    2014-01-01

    Stroke is an important cause of severe disability and impaired motor function. Treatment modalities that improve motor function in patients with stroke are needed. The objective of this study was to investigate the effect of kinesthetic taping of the anterior thigh and knee on maximal walking speed and clinical indices of spasticity in patients with stroke. Thirty-two patients (9 women) receiving rehabilitation after stroke (average, 50 days since stroke) who had impaired walking ability were recruited. Primary outcome was maximal walking speed measured by the 10-meter walk test. Secondary outcomes were number of steps taken during the test and clinical signs of spasticity measured by the Tardieu Scale. Tests were conducted before and immediately after application of kinesthetic tape to the anterior thigh and knee of the paretic lower limb. After application of the tape, the maximal walking speed increased, on average, by 0.08 m/s (95% CI, 0.04 to 0.12; P kinesthetic taping of the anterior thigh and knee provides an immediate improvement in walking function in patients with stroke. Such a positive effect on motor function could be a valuable adjunct in physical therapy and rehabilitation of patients with stroke.

  19. Library 3.0 intelligent libraries and apomediation

    CERN Document Server

    Kwanya, Tom; Underwood, Peter

    2015-01-01

    The emerging generation of research and academic library users expect the delivery of user-centered information services. 'Apomediation' refers to the supporting role librarians can give users by stepping in when users need help. Library 3.0 explores the ongoing debates on the "point oh” phenomenon and its impact on service delivery in libraries. This title analyses Library 3.0 and its potential in creating intelligent libraries capable of meeting contemporary needs, and the growing role of librarians as apomediators. Library 3.0 is divided into four chapters. The first chapter introduces and places the topic in context. The second chapter considers "point oh” libraries. The third chapter covers library 3.0 librarianship, while the final chapter explores ways libraries can move towards '3.0'.

  20. Croatian library leaders’ views on (their library quality

    Directory of Open Access Journals (Sweden)

    Kornelija Petr Balog

    2014-04-01

    Full Text Available The purpose of this paper is to determine and describe the library culture in Croatian public libraries. Semi-structured interviews with 14 library directors (ten public and four academic were conducted. The tentative discussion topics were: definition of quality, responsibility for quality, satisfaction with library services, familiarization with user perspective of library and librarians, monitoring of user expectations and opinions. These interviews incorporate some of the findings of the project Evaluation of library and information services: public and academic libraries. The project investigates library culture in Croatian public and academic libraries and their preparedness for activities of performance measurement. The interviews reveal that library culture has changed positively in the past few years and that library leaders have positive attitude towards quality and evaluation activities. Library culture in Croatian libraries is a relatively new concept and as such was not actively developed and/or created. This article looks into the library culture of Croatian libraries, but at the same time investigates whether there is any trace of culture of assessment in them. Also, this article brings the latest update on views, opinions and atmosphere in Croatian public and academic libraries.

  1. Reflection on the talent structure of knowledge-service oriented nuclear technology library

    International Nuclear Information System (INIS)

    Zhang Xue; Zhang Ruiping

    2010-01-01

    Nuclear technology library is the only authoritative organization in collection of nuclear technology literatures.It has exceptional advantage and a large number of customers with great requirement. With promotion of network and digitization of information resource, new situation is posed before nuclear technology library-transforming from traditional library to knowledge-service oriented library. In order to carry on knowledge service effectively and conveniently, a variety of talents are essential. So establishing a talent team with high quality and complete specialities is the fundamental guarantee. Based on a great deal research and discussion, requirements for establishment of a talent team are put forward in the paper and suggestion are present: 5 basic specialized talents are required in nuclear technology library, including organization and management talent, basic operation talent, search service talent, technology application talent, information development talent. (authors)

  2. Comparison of Tension-free Vaginal Tape Versus Transobturator Tape in Women with Stress Urinary Incontinence

    Directory of Open Access Journals (Sweden)

    Zinat Ghanbari

    2007-06-01

    Full Text Available Objective: This study compared the Tension-free vaginal tape (TVT and Transobturator tape (TOT procedures for surgical treatment of stress urinary incontinence in women.Materials and methods: This prospective non randomized clinical trial was conducted in Vali-e-asr hospital from March 2001 to March 2005. A total of 71 patients with clinical and urodynamic diagnosis of Stress urinary incontinence (SUI were enrolled in the study. Patients were divided into two groups and underwent TVT or TOT procedures. Mean operation time, cure rate, post operative urinary retention, bleeding and infection were compared between two groups. SPSS software was used for statistical analysis. Chi square and fisher exact test calculated the effects of the nominal variables. Mean difference of quantitative variables were compared by student's T- test. P ≤0.05 was considered statistically significant. Results: There was no significant difference in mean time of operation and peri-operative complications among groups. Urinary retention was 13.8% (n=5 in the TVT group versus 2.8% (n=1 in TOT group (NS. The rates of cure (91.6% vs 91.4%, improvement (5.6% vs 8.6% and failure (2.8% vs 0 were similar for the TVT and TOT groups. The rate of hemorrhagic complications was 5.5% in TVT and 2.8% in TOT group (NS.Conclusion: TOT appears to be equally efficient to TVT for surgical treatment of stress urinary incontinence after 30 months follow-up.

  3. Spectrum-to-Spectrum Searching Using a Proteome-wide Spectral Library*

    Science.gov (United States)

    Yen, Chia-Yu; Houel, Stephane; Ahn, Natalie G.; Old, William M.

    2011-01-01

    The unambiguous assignment of tandem mass spectra (MS/MS) to peptide sequences remains a key unsolved problem in proteomics. Spectral library search strategies have emerged as a promising alternative for peptide identification, in which MS/MS spectra are directly compared against a reference library of confidently assigned spectra. Two problems relate to library size. First, reference spectral libraries are limited to rediscovery of previously identified peptides and are not applicable to new peptides, because of their incomplete coverage of the human proteome. Second, problems arise when searching a spectral library the size of the entire human proteome. We observed that traditional dot product scoring methods do not scale well with spectral library size, showing reduction in sensitivity when library size is increased. We show that this problem can be addressed by optimizing scoring metrics for spectrum-to-spectrum searches with large spectral libraries. MS/MS spectra for the 1.3 million predicted tryptic peptides in the human proteome are simulated using a kinetic fragmentation model (MassAnalyzer version2.1) to create a proteome-wide simulated spectral library. Searches of the simulated library increase MS/MS assignments by 24% compared with Mascot, when using probabilistic and rank based scoring methods. The proteome-wide coverage of the simulated library leads to 11% increase in unique peptide assignments, compared with parallel searches of a reference spectral library. Further improvement is attained when reference spectra and simulated spectra are combined into a hybrid spectral library, yielding 52% increased MS/MS assignments compared with Mascot searches. Our study demonstrates the advantages of using probabilistic and rank based scores to improve performance of spectrum-to-spectrum search strategies. PMID:21532008

  4. Creative Destruction in Libraries: Designing our Future

    Directory of Open Access Journals (Sweden)

    Caro Pinto

    2013-11-01

    Full Text Available In Brief: Joseph Schumpeter defines creative destruction as a “process of industrial mutation that incessantly revolutionizes the economic structure from within, incessantly destroying the old one, incessantly creating a new one.” As libraries struggle with how to position themselves to thrive in the digital age, how can we balance the traditional elements of librarianship like […

  5. 'Twisted tape sign': Its significance in recurrent sigmoid volvulus

    Energy Technology Data Exchange (ETDEWEB)

    Gopal, K. [Tameside and Glossop Acute Services NHS Trust, Fountain Street, Ashton-under-Lyne OL6 9RW (United Kingdom)]. E-mail: karthikgopal73@yahoo.co.uk; Lim, Y. [Tameside and Glossop Acute Services NHS Trust, Fountain Street, Ashton-under-Lyne OL6 9RW (United Kingdom); Banerjee, B. [Tameside and Glossop Acute Services NHS Trust, Fountain Street, Ashton-under-Lyne OL6 9RW (United Kingdom)

    2005-11-01

    Aim: Sigmoid volvulus is a common cause of intestinal obstruction in the elderly. Mild attacks of sigmoid volvulus may be more difficult to diagnose due to the lack of severity of symptoms which may resolve spontaneously only to recur after an interval. This study was a review of patients to assess the incidence of the 'twisted tape sign' and to evaluate the significance of its presence in cases of recurrent sigmoid volvulus. Methods and materials: A retrospective study over eight years revealed six cases of surgically confirmed recurrent sigmoid volvulus. Case records and barium enemas of all patients were reviewed. Results: Six patients were identified, including four men and two women, with a median age of 56 years. Diagnostic difficulties were encountered in four (67%) patients with a delay ranging between 10 and 37 months with a mean 17.3 months. Twisted tape sign was confirmed on all barium examinations retrospectively. Conclusion: Recognition of twisted tape sign on barium enema examination along with an appropriate clinical history would suggest a diagnosis of recurrent sigmoid volvulus.

  6. Effect of Mulligan's and Kinesio knee taping on adolescent ballet dancers knee and hip biomechanics during landing.

    Science.gov (United States)

    Hendry, D; Campbell, A; Ng, L; Grisbrook, T L; Hopper, D M

    2015-12-01

    Taping is often used to manage the high rate of knee injuries in ballet dancers; however, little is known about the effect of taping on lower-limb biomechanics during ballet landings in the turnout position. This study investigated the effects of Kinesiotape (KT), Mulligan's tape (MT) and no tape (NT) on knee and hip kinetics during landing in three turnout positions. The effect of taping on the esthetic execution of ballet jumps was also assessed. Eighteen pain-free 12-15-year-old female ballet dancers performed ballet jumps in three turnout positions, under the three knee taping conditions. A Vicon Motion Analysis system (Vicon Oxford, Oxford, UK) and Advanced Mechanical Technology, Inc. (Watertown, Massa chusetts, USA) force plate collected lower-limb mechanics. The results demonstrated that MT significantly reduced peak posterior knee shear forces (P = 0.025) and peak posterior (P = 0.005), medial (P = 0.022) and lateral (P = 0.014) hip shear forces compared with NT when landing in first position. KT had no effect on knee or hip forces. No significant differences existed between taping conditions in all landing positions for the esthetic measures. MT was able to reduce knee and the hip forces without affecting the esthetic performance of ballet jumps, which may have implications for preventing and managing knee injuries in ballet dancers. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Bi axially textured YBCO coated tape prepared using dynamic magnetic grain alignment

    International Nuclear Information System (INIS)

    Genoud, Jean-Yves; Quinton, William

    1999-01-01

    A new magnetic grain alignment technique has been applied to produce bi axially aligned YBCO coated tapes. A bi axially aligned dispersion of orthorhombic Y 2 Ba 4 Cu 7 O 15 (Y-247) powder was settled on un textured silver substrates. The Y-247 tapes were then melt processed to achieve high critical current YBa 2 Cu 3 O 7 (Y-123) tapes with CuO as a secondary phase. The biaxial alignment is preserved after the densification process and a clear enhancement of J c relative to identically prepared un textured or uniaxially textured samples is obtained. Critical current densities of up to 5000 A cm -2 at 77 K in self-field and 1500 A cm -2 in 0.5 T magnetic field at 65 K were obtained in films from 20 to 40 μm thick. Problems were experienced in achieving fully densified thick films while retaining biaxial texture. The initial grain size distribution was found to have a major influence on the final microstructure. Provided significant improvements in J c can be obtained this method offers an alternative to coated tape processes based on epitaxial growth which has the advantage that it does not require textured substrates. The biaxial alignment technique described here intrinsically acts on the bulk material rather than at surfaces. This offers the possibility of texturing without thickness limitations. (author)

  8. Effect of kinesio taping on lower limb joint powers in individuals with genu varum.

    Science.gov (United States)

    Jafarnezhadgero, AmirAli; Shad, Morteza Madadi; Majlesi, Mahdi; Zago, Matteo

    2018-04-01

    Therapeutic lateral knee joint muscle taping potentially offers a low-risk, economical and effective alternative for the clinical treatment of light to moderate knee overload, due to misalignment in patients with genu varum. In this study, we aimed at investigating the immediate effect of lateral knee joint muscular kinesio taping on lower limb joint powers, during the stance phase of walking, in individuals with genu varum. Fifteen male subjects with genu varum misalignment (age: 24.2±3.7 years) participated in the study. Subjects performed three walking trials without, and three with, biceps femoris and vastus lateralis kinesio taping. The three-dimensional position coordinate data of reflective markers were collected at 100 Hz using a six-cameras Vicon system (Motion Analysis Corp., UK). Additionally, two Kistler force plates (Kistler AG, Winterthur, Switzerland) were used to record the Ground Reaction Forces (GRF) components at 1000 Hz during stance phase of walking. A three-way ANOVA with post-hoc testing (using paired samples Student's t-test with Bonferroni correction) was performed to compare the power values of lower limb joints before and after the use of KT. With kinesio taping, we observed that the average negative power increased at the ankle level in dominant limb, (P<0.05, 10-20% of gait cycle, GC), and at the knee level in both limbs (10-20% and 60-80% GC). Further, average negative power of the non-dominant knee joint (80-100% GC) and positive power of the non-dominant hip joint (60-80% GC) significantly reduced (P<0.05) in kinesio taping condition. The biomechanical analysis of joint power during walking using kinesio taping provided essential information about the possible mechanisms involved in gait analysis with this intervention in adults with genu varus. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Bingham plastic fluid flow model in tape casting of ceramics using two doctor blades – analytical approach

    DEFF Research Database (Denmark)

    Jabbari, Masoud; Hattel, Jesper Henri

    2014-01-01

    One of the most common processes used in manufacturing of multilayer ceramic packages, multilayer capacitors and large scale integration circuits is tape casting. In this process, the wet tape thickness is one of the single most determining parameters affecting the final properties of the product......, and it is therefore of great interest to be able to control it. One way to control the tape thickness is to use a two doctor blade configuration in the tape casting machine. In this case, it becomes important to fix the height of the slurry in front of both doctor blades according to the desired tape thickness...... and casting speed (belt velocity). In the present work, the flow in both doctor blade regions of a slurry is described with a steady state momentum equation in combination with a Bingham plastic constitutive equation, and this is integrated to a closed form analytical solution for both reservoirs based...

  10. SHORT TERM EFFECT OF MULLIGANS MOBILIZATION VERSUS KINESIO TAPING ON KNEE PAIN AND DISABILITY FOR OSTEOARTHRITIS OF KNEE

    Directory of Open Access Journals (Sweden)

    Priyesh P. Malgaonkar

    2014-10-01

    Full Text Available Background: Mulligan’s mobilization and Kinesio taping treatment techniques found to be effective on improving pain and functional disability for osteoarthritis of knee. Hence the purpose is to compare the effect of Mulligan’s mobilization and kinesio taping on improvement of pain and functional disability in subjects with osteoarthritis of knee. Method: An experimental study design, 40 subjects with osteoarthritis of knee joint randomized 20 subjects each into Mobilization Group and Taping Group. Mobilization Group was treated with Mulligan’s Mobilization and Taping Group was treated with Therapeutic Kinesio Taping thrice a week for 2 weeks. Outcome measurements such as Visual analog scale (VAS for pain, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC for functional disability was measured before and after 2 weeks post intervention. Results: Analysis using Paired ‘t’ test and Wilcoxon signed rank test found that there is a statistically significant improvement in VAS and WOMAC within the group. Comparative analysis using Independent‘t’ test and Mann Whitney U test found there is a statistically significant difference in post-intervention means between the groups. Conclusion: The study concluded that both Mulligan’s Mobilization and Kinesio Taping techniques significantly shown short term effect on improvement of pain and functional disability for subjects with osteoarthritis of knee. However, there is no statistically significant difference in short term improvements between Mulligan’s Mobilization and Kinesio Taping. Among both, Mulligan’s Mobilization technique found clinically more effective with greater percentage of improvement than Kinesio Taping technique.

  11. Low-cost fabrication of thin-walled solid electrolyte tubes from doctor-bladed ceramic tape

    Energy Technology Data Exchange (ETDEWEB)

    Dirstine, R T

    1979-01-01

    Sodium ..beta..-Al/sub 2/O/sub 3/ tubes having wall thicknesses of typically 0.4 mm were fabricated from doctor-bladed (cast) ceramic tape by use of proprietary organic slip compositions and zeta-processed, lithia-stabilized alumina power. The ceramic tubes fabricated from cast tape had low porosity, low resistivity (approx. 4 ohm-cm at 300/sup 0/C), and good mechanical strength. Alternative fabrication techniques for manufacture of tubes from tape were evaluated, and the primary processing requirements/obstacls were identified. Closed-end tubes, nominally 10 mm outer diameter, 60 mm in length, and with a wall thickness of 0.3 mm, were supplied to the Department of Energy. 26 figures, 10 tables.

  12. Magneto-optical investigations of Ag-sheathed Bi-2223 tapes with ferromagnetic shielding

    International Nuclear Information System (INIS)

    Yurchenko, V.V.; Shantsev, D.V.; Galperin, Y.M.; Alamgir, A.K.M.; Han, Z.; Johansen, T.H.

    2007-01-01

    An increase in the critical current and suppression of AC losses in superconducting wires and tapes with soft magnetic sheath have been predicted theoretically and confirmed experimentally. In this work we present the results of magneto-optical investigations on a series of Ag-sheathed Bi-2223 tapes with Ni coating. We visualize distributions of magnetic field at increasing external field and different temperatures, demonstrating a difference between the flux propagation in the superconductor with Ni rims and a reference sample without Ni coating

  13. Magneto-optical investigations of Ag-sheathed Bi-2223 tapes with ferromagnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Yurchenko, V.V.; Shantsev, D.V.; Galperin, Y.M. [University of Oslo, Department of Physics, P.O. Box 1048, Blindern, 0316 Oslo (Norway); Alamgir, A.K.M.; Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China); Johansen, T.H. [University of Oslo, Department of Physics, P.O. Box 1048, Blindern, 0316 Oslo (Norway)], E-mail: tomhj@fys.uio.no

    2007-09-01

    An increase in the critical current and suppression of AC losses in superconducting wires and tapes with soft magnetic sheath have been predicted theoretically and confirmed experimentally. In this work we present the results of magneto-optical investigations on a series of Ag-sheathed Bi-2223 tapes with Ni coating. We visualize distributions of magnetic field at increasing external field and different temperatures, demonstrating a difference between the flux propagation in the superconductor with Ni rims and a reference sample without Ni coating.

  14. High critical current Ag and Ag alloy sheathed multifilament Bi-2223 tapes

    DEFF Research Database (Denmark)

    Wang, W.G.; Han, Z.; Skov-Hansen, P.

    1999-01-01

    of 0.16x2.8 mm(2) and silver/superconductor ratios of 4.4:1. By reducing the silver ratio, a J(e) of 14 kA/cm(2) with an I, of 38 A has been obtained in 55 filament tapes and an I-c of 84 A has been obtained in a tape with dimensions of 4x0.23 mm(2). A record J(c) of more than 30 kA/cm(2) with an I...

  15. My Own Private Public Library

    Directory of Open Access Journals (Sweden)

    Julia Rone

    2014-11-01

    Full Text Available The present paper analyzes the emergence of Bulgarian digital libraries with pirated literature as a form of compensation for the failure of both the state and the market to provide easy access to electronic books in Bulgarian. These grass-roots digital libraries can be understood best through an analysis of the dichotomies between formal and informal economy, law and ethics, commercial and non-commercial interest, bricolage and engineering. Sharing of books online in Bulgaria has its historical precedent in the sharing of cultural objects during socialism and is part of the larger logic of informal economy as a form of independence from/resistance to the state. While many of the books in these electronic libraries are uploaded in infringement of copyright, the creators and users of the sites defend them on the basis of what is ethically right and claim that they contribute to the spread of knowledge. The paper emphasizes the rhetorical force of the word ‘library’ which is being appropriated by both commercial and non-commercial actors. Without underestimating the value provided by many of the grass-roots digital libraries discussed, the analysis leads to the question whether the bottom-up collaborative strategy for digitizing books is the optimal one in terms of the variety of titles offered and the overall coherence of digital archives. In short, should sharing replace more traditional state policies in the field of culture?

  16. Experiment of enhancing critical current in Bi-2223/Ag tape by means of ferromagnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Alamgir, A.K.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)]. E-mail: alam643@hotmail.com; Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)

    2005-11-15

    Critical current in multifilamentary Ag-sheath Bi-2223 tape is enhanced to some extent by means of thin and narrow coating of pure nickel. The concept of enhancing critical current is based on the magnetic shielding effect resulting in redirection of self-field flux lines. The Ni coating was introduced at the edge regime of the tape in order to redirect the perpendicular component of self-field lines which is severe at the edges. Critical current in a typical Ag-sheath Bi-2223 tape was enhanced up to {approx}11% by 50 {mu}m thick and 0.4 mm long Ni coating without any change of self-field loss. This fact reveals that additional ferromagnetic loss could be compensated by the shielding effect and increased critical current of the tape. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the length and thickness of ferromagnetic coating introduced. Therefore, it is very important to control the geometry of ferromagnetic coating in order to balance the critical current and ac loss for optimum superconductor performance. Introduction of ferromagnetic coating and its effect on electromagnetic properties in multifilamentary Bi-2223/Ag tape will be reported in this article.

  17. Experiment of enhancing critical current in Bi-2223/Ag tape by means of ferromagnetic shielding

    International Nuclear Information System (INIS)

    Alamgir, A.K.M.; Gu, C.; Han, Z.

    2005-01-01

    Critical current in multifilamentary Ag-sheath Bi-2223 tape is enhanced to some extent by means of thin and narrow coating of pure nickel. The concept of enhancing critical current is based on the magnetic shielding effect resulting in redirection of self-field flux lines. The Ni coating was introduced at the edge regime of the tape in order to redirect the perpendicular component of self-field lines which is severe at the edges. Critical current in a typical Ag-sheath Bi-2223 tape was enhanced up to ∼11% by 50 μm thick and 0.4 mm long Ni coating without any change of self-field loss. This fact reveals that additional ferromagnetic loss could be compensated by the shielding effect and increased critical current of the tape. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the length and thickness of ferromagnetic coating introduced. Therefore, it is very important to control the geometry of ferromagnetic coating in order to balance the critical current and ac loss for optimum superconductor performance. Introduction of ferromagnetic coating and its effect on electromagnetic properties in multifilamentary Bi-2223/Ag tape will be reported in this article

  18. Simulation of magnetization and levitation characteristics of HTS tape stacks

    Science.gov (United States)

    Anischenko, I. V.; Pokrovskii, S. V.; Mineev, N. A.

    2017-12-01

    In this work it is presented a computational model of a magnetic levitation system based on stacks of high-temperature second generation superconducting tapes (HTS) GdBa2Cu3O7-x. Calculated magnetic field and the current distributions in the system for different stacks geometries in the zero-field cooling mode are also presented. The magnetization curves of the stacks in the external field of a permanent NdFeB magnet and the levitation force dependence on the gap between the magnet and the HTS tapes stack were obtained. A model of the magnetic system, oriented to levitation application, is given. Results of modeling were compared with the experimental data.

  19. 75 FR 75393 - Schools and Libraries Universal Service Support Mechanism and A National Broadband Plan for Our...

    Science.gov (United States)

    2010-12-03

    ... absolve schools and libraries of their obligation to adhere to the Children's Internet Protection Act.... Section 254(h)(1)(B) requires telecommunications carriers to provide universal service to schools and... schools and libraries the same services that a traditional telecommunications carrier can provide a school...

  20. Test des photomultiplicateurs en silicium couplés à un scintillateur plastique pour la nouvelle Tape Station

    CERN Document Server

    sekal, Smain

    2014-01-01

    L’une des parties essentielles de la l’installation ISOLDE est la tape Station (contrôleur de bandes), qui permet la vérification de la qualité du faisceau délivré aux expériences. On prévoit à ISOLDE de remplacer l’ancienne Tape Station, par une nouvelle Tape station; et l’un des paramètres essentiels pour la performance de la tape Station est l’efficacité de détection. Le but de ce travail est de vérifier l’efficacité des détecteurs de particules bêta, composés par l’association des photomultiplicateurs en Silicium à un scintillateur plastique pour differentes distances.