  1. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  2. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  3. Total lymphocyte count and subpopulation lymphocyte counts in relation to dietary intake and nutritional status of peritoneal dialysis patients.

    Science.gov (United States)

    Grzegorzewska, Alicja E; Leander, Magdalena

    2005-01-01

    Dietary deficiency causes abnormalities in circulating lymphocyte counts. For the present paper, we evaluated correlations between total and subpopulation lymphocyte counts (TLC, SLCs) and parameters of nutrition in peritoneal dialysis (PD) patients. Studies were carried out in 55 patients treated with PD for 22.2 +/- 11.4 months. Parameters of nutritional status included total body mass, lean body mass (LBM), body mass index (BMI), and laboratory indices [total protein, albumin, iron, ferritin, and total iron binding capacity (TIBC)]. The SLCs were evaluated using flow cytometry. Positive correlations were seen between TLC and dietary intake of niacin; TLC and CD8 and CD16+56 counts and energy delivered from protein; CD4 count and beta-carotene and monounsaturated fatty acids 17:1 intake; and CD19 count and potassium, copper, vitamin A, and beta-carotene intake. Anorexia negatively influenced CD19 count. Serum albumin showed correlations with CD4 and CD19 counts, and LBM with CD19 count. A higher CD19 count was connected with a higher red blood cell count, hemoglobin, and hematocrit. Correlations were observed between TIBC and TLC and CD3 and CD8 counts, and between serum Fe and TLC and CD3 and CD4 counts. Patients with a higher CD19 count showed a better clinical-laboratory score, especially less weakness. Patients with a higher CD4 count had less expressed insomnia. Quantities of ingested vitamins and minerals influence lymphocyte counts in the peripheral blood of PD patients. Evaluation of TLC and SLCs is helpful in monitoring the effectiveness of nutrition in these patients.

  4. Dose equivalent distributions in the AAEC total body nitrogen facility

    International Nuclear Information System (INIS)

    Allen, B.J.; Bailey, G.M.; McGregor, B.J.

    1985-01-01

    The incident neutron dose equivalent in the AAEC total body nitrogen facility is measured by a calibrated remmeter. Dose equivalent rates and distributions are calculated by Monte Carlo techniques which take account of the secondary neutron flux from the collimator. Experiment and calculation are found to be in satisfactory agreement. The effective dose equivalent per exposure is determined by weighting organ doses, and the potential detriment per exposure is calculated from ICRP risk factors

  5. Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities

    International Nuclear Information System (INIS)

    Ma, R.; Ellis, K.J.; Shypailo, R.J.; Pierson, R.N. Jr.

    1999-01-01

    This study compares two independently calibrated delayed-gamma neutron activation (DGNA) facilities, one at the Brookhaven National Laboratory (BNL), Upton, New York, and the other at the Children's Nutrition Research Center (CNRC), Houston, Texas that measure total body calcium (TBCa). A set of BNL phantoms was sent to CNRC for neutron activation analysis, and a set of CNRC phantoms was measured at BNL. Both facilities showed high precision (<2%), and the results were in good agreement, within 5%. (author)

  6. Comparative seric TGF(β1, β2) levels and platelets count response in total body irradiated baboons

    International Nuclear Information System (INIS)

    Mestries, J.C.; Veyret, J.; Agay, D.; Van Uye, A.; Caterini, R.; Herodin, F.; Mathieu, J.; Chancerelle, Y.

    1994-01-01

    Total body irradiation associated or not with r-hIL-6 treatment a relation between TGF-β1 and TGF-β2 blood levels and platelets count. During radio-induced thrombocytopenia, by decreasing its ability to inhibit proliferation of stem cells and megakaryocytopoiesis, the TGF-β falling induced a favorable condition for hematopoietic recovery. (author)

  7. Total body water and total body potassium in anorexia nervosa

    Energy Technology Data Exchange (ETDEWEB)

    Dempsey, D.T.; Crosby, L.O.; Lusk, E.; Oberlander, J.L.; Pertschuk, M.J.; Mullen, J.L.

    1984-08-01

    In the ill hospitalized patient with clinically relevant malnutrition, there is a measurable decrease in the ratio of the total body potassium to total body water (TBK/TBW) and a detectable increase in the ratio of total exchangeable sodium to total exchangeable potassium (Nae/Ke). To evaluate body composition analyses in anorexia nervosa patients with chronic uncomplicated semistarvation, TBK and TBW were measured by whole body K40 counting and deuterium oxide dilution in 10 females with stable anorexia nervosa and 10 age-matched female controls. The ratio of TBK/TBW was significantly (p less than 0.05) higher in anorexia nervosa patients than controls. The close inverse correlation found in published studies between TBK/TBW and Nae/Ke together with our results suggest that in anorexia nervosa, Nae/Ke may be low or normal. A decreased TBK/TBW is not a good indicator of malnutrition in the anorexia nervosa patient. The use of a decreased TBK/TBW ratio or an elevated Nae/Ke ratio as a definition of malnutrition may result in inappropriate nutritional management in the patient with severe nonstressed chronic semistarvation.

  8. Total body water and total body potassium in anorexia nervosa

    International Nuclear Information System (INIS)

    Dempsey, D.T.; Crosby, L.O.; Lusk, E.; Oberlander, J.L.; Pertschuk, M.J.; Mullen, J.L.

    1984-01-01

    In the ill hospitalized patient with clinically relevant malnutrition, there is a measurable decrease in the ratio of the total body potassium to total body water (TBK/TBW) and a detectable increase in the ratio of total exchangeable sodium to total exchangeable potassium (Nae/Ke). To evaluate body composition analyses in anorexia nervosa patients with chronic uncomplicated semistarvation, TBK and TBW were measured by whole body K40 counting and deuterium oxide dilution in 10 females with stable anorexia nervosa and 10 age-matched female controls. The ratio of TBK/TBW was significantly (p less than 0.05) higher in anorexia nervosa patients than controls. The close inverse correlation found in published studies between TBK/TBW and Nae/Ke together with our results suggest that in anorexia nervosa, Nae/Ke may be low or normal. A decreased TBK/TBW is not a good indicator of malnutrition in the anorexia nervosa patient. The use of a decreased TBK/TBW ratio or an elevated Nae/Ke ratio as a definition of malnutrition may result in inappropriate nutritional management in the patient with severe nonstressed chronic semistarvation

  9. In vivo Prompt Gamma Neutron Activation Analysis Facility for Total Body Nitrogen and Cd

    International Nuclear Information System (INIS)

    Munive, Marco; Revilla, Angel; Solis, Jose L.

    2007-01-01

    A Prompt Gamma Neutron Activation Analysis (PGNAA) system has been designed and constructed to measure the total body nitrogen and Cd for in vivo studies. An aqueous solution of KNO 3 was used as phantom for system calibration. The facility has been used to monitor total body nitrogen (TBN) of mice and found that is related to their diet. Some mice swallowed diluted water with Cl 2 Cd, and the presence of Cd was detected in the animals. The minimum Cd concentration that the system can detect was 20 ppm

  10. Dependence of a whole body counting efficiency on body size and composition

    International Nuclear Information System (INIS)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R.

    2001-01-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  11. Dependence of a whole body counting efficiency on body size and composition

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2001-07-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  12. Estimation of Total Body Fat from Potassium-40 Content

    International Nuclear Information System (INIS)

    Taha Mohamed Taha Ahmed, T.M.T.

    2010-01-01

    This paper concerns on estimation of total body fat from potassium 40 content using total body counting technique. The work performed using fast scan whole body counter. Calibration of that system for K-40 was carried out under assumption that uniformity distribution of radioactivity of potassium was distributed in 10 polyethylene bottles phantom. Different body sizes were represented by 2, 4, 6, 8 and 10 polyethylene bottles; each bottle has a volume of 0.04 m3. The counting efficiency for each body size was determined. Lean body weight (LBW) was calculated for ten males and ten females using appropriate mathematical equation. Total Body Potassium, TBK for the same selected group was measured using whole body counter. A mathematical relationship between lean body weight and potassium content was deduced .Fat contents for some individuals were calculated and weight/height ratio was indicated for fatness.

  13. In vivo prompt gamma activation analysis facility for total body nitrogen and cadmium

    International Nuclear Information System (INIS)

    Munive, Marco; Solis, Jose; Revilla, Angel

    2008-01-01

    Full text: Prompt Neutron Activation Analysis (PGNAA) is a technique that could have medical applications, like determination of body's contents of protein and heavy metals in vivo. The in vivo PGNAA facility, contains a neutron source (Cf-252) with safety device, a compartment for animal irradiation, and a gamma rays detecting system based on the NaI(Tl) detector with an analytical software. The prompt gamma rays were emitted after 10 -15 s of the interaction, so they don't produce radioactive waste, and have a characteristics energy for each element, i.e. a strong peak at 2.24 MeV is observed for H. The facility has been used with laboratory mice. Water-filled phantom placed in the neutron beam was used to system calibration. Three study groups of 5 mice each one were selected and were feed with a different diet and the total body nitrogen (TBN) of the mice was monitored with the facility. The diet produced a different TBN for each group. Some mice drunk diluted water with Cl 2 Cd, so the presence of Cd was detected in the mouse. The minimum Cd concentration that the system can detect was 20 ppm. The total dose (neutron and gamma dose was measured from TLDs and simulated by MNCP-4B in the sample compartment during the irradiation time (5 minutes) is less than 2.5 mSv. This total dose is low than the dose from other analytical radiological techniques (25 a 50 mSv). (author)

  14. The ACCUSCAN-II vertical scanning germanium whole body counter

    International Nuclear Information System (INIS)

    Bronson, F.L.

    1987-01-01

    The ACCUSCAN-II is manufactured by Canberra Industries, and represents a new generation of WBC systems. One or two Germanium detectors are used for precise nuclide identification. The detectors scan the total body and can accurately quantify radioactive material anywhere in the body. The shield is a full 4'' thick steel or 2'' lead and weighs about 9000 lbs. The subject can be counted standing for full body scans, or seated for longer counting times of limited portions of the body. Optional electronics also generate a count rate vs. body position profile, as an aid to interpretation of the dose implications of the count. Typical LLD's are 5 - 10 nCi for a 5 minute total body count and 0.5 - 0.7 nCi for a 5 minute long screening count. The system is available in several flavors. The manual version is an inexpensive system intended for universities, hospitals and small industrial facilities. The automatic system includes a MicroVAX-II computer and runs ABACOS0-II Body Burden Software, and is ideal for facilities with large numbers of people to count and where automated analysis of the data is desirable

  15. Determining eligibility for antiretroviral therapy in resource-limited settings using total lymphocyte counts, hemoglobin and body mass index

    Directory of Open Access Journals (Sweden)

    Solberg Peter

    2007-01-01

    Full Text Available Abstract Background CD4+ T lymphocyte (CD4 cell count testing is the standard method for determining eligibility for antiretroviral therapy (ART, but is not widely available in sub-Saharan Africa. Total lymphocyte counts (TLCs have not proven sufficiently accurate in identifying subjects with low CD4 counts. We developed clinical algorithms using TLCs, hemoglobin (Hb, and body mass index (BMI to identify patients who require ART. Methods We conducted a cross-sectional study of HIV-infected adults in Uganda, who presented for assessment for ART-eligibility with WHO clinical stages I, II or III. Two by two tables were constructed to examine TLC thresholds, which maximized sensitivity for CD4 cell counts ≤ 200 cells μL, while minimizing the number offered ART with counts > 350 cells μL. Hb and BMI values were then examined to try to improve model performance. Results 1787 subjects were available for analysis. Median CD4 cell counts and TLCs, were 239 cells/μL and 1830 cells/μL, respectively. Offering ART to all subjects with a TLCs ≤ 2250 cells/μL produced a sensitivity of 0.88 and a false positive ratio of 0.21. Algorithms that treated all patients with a TLC 3000 cells/μL, and used Hb and/or BMI values to determine eligibility for those with TLC values between 2000 and 3000 cells/μL, marginally improved accuracy. Conclusion TLCs appear useful in predicting who would be eligible for ART based on CD4 cell count criteria. Hb and BMI values may be useful in prioritizing patients for ART, but did not improve model accuracy.

  16. Changes in total and differential white cell counts, total lymphocyte ...

    African Journals Online (AJOL)

    Background: Published reports on the possible changes in the various immune cell populations, especially the total lymphocyte and CD4 cell counts, during the menstrual cycle in Nigerian female subjects are relatively scarce. Aim: To determine possible changes in the total and differential white blood cell [WBC] counts, ...

  17. Association of peripheral total and differential leukocyte counts with obesity-related complications in young adults.

    Science.gov (United States)

    Yoshimura, Aya; Ohnishi, Shunsuke; Orito, Chieko; Kawahara, Yukako; Takasaki, Hiroyo; Takeda, Hiroshi; Sakamoto, Naoya; Hashino, Satoshi

    2015-01-01

    Obesity has been demonstrated to be associated with elevated leukocytes in adults and children. This study assessed the associations between peripheral total and differential leukocyte counts and obesity-related complications in young adults. 12 obese (median age 21.5 (range 19-28) years, median BMI 35.7 (range 32.0-44.9) kg/m(2)) and 11 normal (median age 23 (range 18-27) years, median BMI 19.5 (range 18.1-21.7) kg/m(2)) adults were enrolled. Complete blood count and serum levels of liver enzymes, fasting blood glucose, insulin and lipids were measured, and the homeostasis model assessment of insulin resistance was calculated. Fat mass was calculated using a bioimpedance analysis device, and ultrasonography was performed to measure fat thickness and to detect fatty change of the liver. Total leukocyte and monocyte counts were significantly increased in obese young adults. Total leukocyte count was associated with liver enzyme levels, insulin resistance as well as visceral and subcutaneous fat thickness. Neutrophil count was associated with insulin resistance. Lymphocyte count was associated with serum liver enzymes, insulin resistance, and dyslipidemia. Monocyte count was associated with serum liver enzyme, insulin resistance, visceral and subcutaneous fat thickness, body fat mass, and percentage body fat. The results of this study suggest that chronic low-grade systemic inflammation is associated with obesity-related complications such as nonalcoholic fatty liver disease, insulin resistance, and dyslipidemia in young adults. © 2015 S. Karger GmbH, Freiburg.

  18. A new method of body habitus correction for total body potassium measurements

    International Nuclear Information System (INIS)

    O'Hehir, S; Green, S; Beddoe, A H

    2006-01-01

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use

  19. A new method of body habitus correction for total body potassium measurements

    Energy Technology Data Exchange (ETDEWEB)

    O' Hehir, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Green, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Beddoe, A H [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom)

    2006-09-07

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use.

  20. Body protein losses estimated by nitrogen balance and potassium-40 counting

    International Nuclear Information System (INIS)

    Belyea, R.L.; Babbitt, C.L.; Sedgwick, H.T.; Zinn, G.M.

    1986-01-01

    Body protein losses estimated from N balance were compared with those estimated by 40K counting. Six nonlactating dairy cows were fed an adequate N diet for 7 wk, a low N diet for 9 wk, and a replete N diet for 3 wk. The low N diet contained high cell wall grass hay plus ground corn, starch, and molasses. Soybean meal was added to the low N diet to increase N in the adequate N and replete N diets. Intake was measured daily. Digestibilities, N balance, and body composition (estimated by 40K counting) were determined during each dietary regimen. During low N treatment, hay dry matter intake declined 2 kg/d, and supplement increased about .5 kg/d. Dry matter digestibility was not altered by N treatment. Protein and acid detergent fiber digestibilities decreased from 40 and 36% during adequate N to 20 and 2%, respectively, during low N. Fecal and urinary N also declined when cows were fed the low N diet. By the end of repletion, total intake, fiber, and protein digestibilities as well as N partition were similar to or exceeded those during adequate N intake. Body protein (N) loss was estimated by N balance to be about 3 kg compared with 8 kg by 40K counting. Body fat losses (32 kg) were large because of low energy digestibility and intake. Seven kilograms of body fat were regained during repletion, but there was no change in body protein

  1. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  2. Detection of metastatic thyroid carcinoma through whole body counting

    International Nuclear Information System (INIS)

    Novenario, H.S.; Pascacio, F.M.; Cruz, Benjamin de la; Anden, A.B.

    Whole body counters are not only used in measuring radioactivity in the body for radiation protection purposes but also in the measurement of iron absorption, body potassium and cesium, chronic blood loss, and also in the determination of the effectiveness of surgery, thyroid hormone and radioactive iodine therapy in thyroid carcinoma. This report deals with our experience in the use of a shadow-shield whole body counter in the determination of I-131 uptake by metastatic lesions of cancer of thyroid after total thyroidectomy and ablation therapy with I-131. This study was undertaken jointly by the Department of Nuclear Medicine, Veterans Memorial Hospital and the Biomedical Research Division of the Philippine Atomic Energy Commission. Preliminary results indicate that the 22 patients who underwent whole body counting after total thyroidectomy I-131 ablation therapy, 9 patients had elevated percentage retention of I-131, 10 patients with normal values and 3 patients with rising values. Foci of I-131 concentration in those with elevated and rising percentage concentration values were seen in the thyroidal bed scintiscans, while the 10 patients with normal values had negative scintiscans. The results of our observations confirm the results obtained by other workers abroad. Our preliminary results indicate that with the use of whole body counters a sensitive method of assessing whether functioning metastatic lesion of cancer of the thyroid still exist after total thyroidectomy and I-131 ablation therapy can be provided. (author)

  3. Estimation of Radiation Doses in the Marshall Islands Based on Whole Body Counting of Cesium-137 (137Cs) and Plutonium Urinalysis

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, J; Hickman, D; Kehl, S; Hamilton, T

    2007-06-11

    Under the auspices of the U.S. Department of Energy (USDOE), researchers from the Lawrence Livermore National Laboratory (LLNL) have recently implemented a series of initiatives to address long-term radiological surveillance needs at former nuclear test sites in the Republic of the Marshall Islands (RMI). The aim of this radiological surveillance monitoring program (RSMP) is to provide timely radiation protection for individuals in the Marshall Islands with respect to two of the most important internally deposited fallout radionuclides-cesium-137 ({sup 137}Cs) and long-lived isotopes 239 and 240 of plutonium ({sup 239+240}Pu) (Robison et al., 1997 and references therein). Therefore, whole-body counting for {sup 137}Cs and a sensitive bioassay for the presence of {sup 239+240}Pu excreted in urine were adopted as the two most applicable in vivo analytical methods to assess radiation doses for individuals in the RMI from internally deposited fallout radionuclides (see Hamilton et al., 2006a-c; Bell et al., 2002). Through 2005, the USDOE has established three permanent whole-body counting facilities in the Marshall Islands: the Enewetak Radiological Laboratory on Enewetak Atoll, the Utrok Whole-Body Counting Facility on Majuro Atoll, and the Rongelap Whole-Body Counting Facility on Rongelap Atoll. These whole-body counting facilities are operated and maintained by trained Marshallese technicians. Scientists from LLNL provide the technical support and training necessary for maintaining quality assurance for data acquisition and dose reporting. This technical basis document summarizes the methodologies used to calculate the annual total effective dose equivalent (TEDE; or dose for the calendar year of measurement) based on whole-body counting of internally deposited {sup 137}Cs and the measurement of {sup 239+240}Pu excreted in urine. Whole-body counting provides a direct measure of the total amount (or burden) of {sup 137}Cs present in the human body at the time of

  4. Measurement of total-body cobalt-57 vitamin B12 absorption with a gamma camera

    International Nuclear Information System (INIS)

    Cardarelli, J.A.; Slingerland, D.W.; Burrows, B.A.; Miller, A.

    1985-01-01

    Previously described techniques for the measurement of the absorption of [ 57 Co]vitamin B 12 by total-body counting have required an iron room equipped with scanning or multiple detectors. The present study uses simplifying modifications which make the technique more available and include the use of static geometry, the measurement of body thickness to correct for attenuation, a simple formula to convert the capsule-in-air count to a 100% absorption count, and finally the use of an adequately shielded gamma camera obviating the need of an iron room

  5. Evaluation for asbestos exposure in lung cancer surgery cases. Relationships between asbestos body count and pleural plaques and between asbestos body count and pulmonary fibrosis

    International Nuclear Information System (INIS)

    Yusa, Toshikazu; Yasukawa, Tomohisa; Shioda, Hironobu; Hirai, Fumiko; Hiroshima, Kenzo; Kishimoto, Takumi

    2011-01-01

    This study was designed to examine the significance of pleural plaques and pulmonary fibrosis in the evaluation of asbestos exposure level. The subjects were patients who had undergone surgery for lung cancer. There were 64 patients who had pleural plaques based on surgical findings (pleural plaque group) and 9 patients who had neither a history of asbestos exposure nor pleural plaque (control group). An examination was performed regarding the extent of pleural plaques and the presence or absence of pulmonary fibrosis. The relationships between these findings and the asbestos body count in the resected lung were investigated. If chest CT showed no pleural plaque, the case was classified as class 0. If chest CT showed pleural plaques, the CT slice with the most extensive pleural plaque in either side was selected. If the plaque extended to less than one quarter of the inner chest wall, the case was classified as class 1. If the extent was one quarter or more, the case was classified as class 2. The cases were considered to have pulmonary fibrosis if the fibrotic findings were equivalent to those of asbestosis of type 1 or more by chest X-ray photography (XP) and if fibrosis was observed in CT. All other cases were considered not to have pulmonary fibrosis. The median asbestos body counts were 1,018 bodies per gram of dried lung in the pleural plaque group and 263 per gram of dried lung in the control group. There was a statistically significant difference between these groups (p=0.0034). There were 25 patients with class 0 pleural plaque, 17 patients with class 1, and 22 patients with class 2. Their median asbestos body counts were 612, 439, and 5,626 bodies, respectively. All class 0 or 1 patients had an asbestos body count of less than 5,000 bodies. There was no significant difference in the counts between patients with class 0 and 1. All class 2 patients had an asbestos body count of 1,000 bodies or more. The count of class 2 patients was significantly higher

  6. Implantation of total body irradiation in radiotherapy

    International Nuclear Information System (INIS)

    Habitzreuter, Angela Beatriz

    2010-01-01

    Before implementing a treatment technique, the characteristics of the beam under irradiation conditions must be well acknowledged and studied. Each one of the parameters used to calculate the dose has to be measured and validated before its utilization in clinical practice. This is particularly necessary when dealing with special techniques. In this work, all necessary parameters and measurements are described for the total body irradiation implementation in facilities designed for conventional treatments that make use of unconventional geometries to generate desired enlarged field sizes. Furthermore, this work presents commissioning data of this modality at Hospital das Clinicas of Sao Paulo using comparison of three detectors types for measurements of entrance dose during total body irradiation treatment. (author)

  7. Is total lymphocyte count related to nutritional markers in hospitalized older adults?

    Directory of Open Access Journals (Sweden)

    Vânia Aparecida LEANDRO-MERHI

    Full Text Available ABSTRACT BACKGROUND Older patients are commonly malnourished during hospital stay, and a high prevalence of malnutrition is found in hospitalized patients aged more than 65 years. OBJECTIVE To investigate whether total lymphocyte count is related to other nutritional markers in hospitalized older adults. METHODS Hospitalized older adults (N=131 were recruited for a cross-sectional study. Their nutritional status was assessed by the Nutritional Risk Screening (NRS, anthropometry, and total lymphocyte count. The statistical analyses included the chi-square test, Fisher's exact test, and Mann-Whitney test. Spearman's linear correlation coefficient determined whether total lymphocyte count was correlated with the nutritional markers. Multiple linear regression determined the parameters associated with lymphocyte count. The significance level was set at 5%. RESULTS According to the NRS, 41.2% of the patients were at nutritional risk, and 36% had mild or moderate depletion according to total lymphocyte count. Total lymphocyte count was weakly correlated with mid-upper arm circumference (r=0.20507; triceps skinfold thickness (r=0.29036, and length of hospital stay (r= -0.21518. Total lymphocyte count in different NRS categories differed significantly: older adults who were not at nutritional risk had higher mean and median total lymphocyte count ( P =0.0245. Multiple regression analysis showed that higher lymphocyte counts were associated with higher triceps skinfold thicknesses and no nutritional risk according to the NRS. CONCLUSION Total lymphocyte count was correlated with mid-upper arm circumference, triceps skinfold thickness, and nutritional risk according to the NRS. In multiple regression the combined factors that remained associated with lymphocyte count were NRS and triceps skinfold thickness. Therefore, total lymphocyte count may be considered a nutritional marker. Other studies should confirm these findings.

  8. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  9. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  10. Validity of total leucocytes count and neutrophil count (differential leucocytes) in diagnosing suspected acute appendicitis

    International Nuclear Information System (INIS)

    Anwar, M.W.; Abid, I.

    2012-01-01

    Objective: To compare the diagnostic accuracy of Total Leucocytes Count (TLC) with Neutrophil count; Differential Leucocytes Count (DLC) in diagnosing cases of suspected acute appendicitis. Study design: Validation study. Place and duration of the study: Department of Surgery, Combined Military Hospital (CMH) Rawalpindi, from April 2008 to October 2008. Method: A total of 100 patients of Pain right iliac fossae who underwent appendicectomy were included. Detailed history of all the patients was taken for pain in right lower abdomen, its severity, its nature, relieving or provoking factors. Clinical examination was done in detail. Total and Differential Leucocytes Count was done. Every patient's appendix was examined grossly after appendicectomy for evidence of appendicitis. Diagnostic measures of TLC and DLC were calculated by standard formulas. Results: Sensitivity and specificity of TLC is 86.9% and 81.25% respectively and that of DLC is 82% and 68.75% respectively. Accuracy was 86% for TLC and 80% for DLC. Conclusion: TLC is more sensitive, specific and accurate test as compared to DLC and it should be used as diagnostic aid for suspected acute appendicitis cases. (author)

  11. Total lymphocyte count as a substitute to cd4 count in management of hiv infected individuals in resource limited society

    International Nuclear Information System (INIS)

    Daud, M.Y.; Qazi, R.A.

    2015-01-01

    Pakistan is a resource limited society and gold standard parameters to monitor HIV disease activity are very costly. The objective of the study was to evaluate total lymphocyte count (TLC) as a surrogate to CD4 count to monitor disease activity in HIV/AIDS in resource limited society. Methods: This cross sectional study was carried out at HIV/AIDS treatment centre, Pakistan Institute of Medical Sciences (PIMS), Islamabad. A total of seven hundred and seventy four (774) HIV positive patients were enrolled in this study, and their CD4 count and total lymphocyte count were checked to find any correlation between the two by using Spearman ranked correlation coefficient. Results: The mean CD4 count was (434.30 ± 269.23), with minimum CD4 count of (9.00), and maximum of (1974.00). The mean total lymphocyte count (TLC) was (6764.0052 ± 2364.02) with minimum TLC (1200.00) and maximum TLC was (20200.00). Using the Pearson's correlation (r) there was a significant and positive correlation between TLC and CD4 count. (r2=0.127 and p=0.000) at 0.01 level. Conclusion: Our study showed a significant positive correlation between CD4 count and total lymphocyte count (TLC), so TLC can be used as a marker of disease activity in HIV infected patients. (author)

  12. Total bacterial count and somatic cell count in refrigerated raw milk stored in communal tanks

    Directory of Open Access Journals (Sweden)

    Edmar da Costa Alves

    2014-09-01

    Full Text Available The current industry demand for dairy products with extended shelf life has resulted in new challenges for milk quality maintenance. The processing of milk with high bacterial counts compromises the quality and performance of industrial products. The study aimed to evaluate the total bacteria counts (TBC and somatic cell count (SCC in 768 samples of refrigerated raw milk, from 32 communal tanks. Samples were collected in the first quarter of 2010, 2011, 2012 and 2013 and analyzed by the Laboratory of Milk Quality - LQL. Results showed that 62.5%, 37.5%, 15.6% and 27.1% of the means for TBC in 2010, 2011, 2012 and 2013, respectively, were above the values established by legislation. However, we observed a significant reduction in the levels of total bacterial count (TBC in the studied periods. For somatic cell count, 100% of the means indicated values below 600.000 cells/mL, complying with the actual Brazilian legislation. The values found for the somatic cell count suggests the adoption of effective measures for the sanitary control of the herd. However, the results must be considered with caution as it highlights the need for quality improvements of the raw material until it achieves reliable results effectively.

  13. The public whole body counting program following the Three Mile Island accident. Technical report, April-September 1979

    International Nuclear Information System (INIS)

    Gotchy, R.L.; Bores, R.J.

    1980-12-01

    In early April, 1979 the U.S. Nuclear Regulatory instituted a program to determine whether any radioactivity released as a result of the March 28, 1979 accident at the Three Mile Island Unit-2 was accumulating in members of the general public living near Unit-2. The program used a device called a whole body counter which has the capability of measuring very small quantities of radioactivity in people. There were 753 men, women and children successfully counted; nine of these people were counted a second time, leading to a total of 762 whole body counts. There was no radioactivity identified in any member of the public which could have originated from the radioactive materials released following the accident. Several people with higher than average levels of naturally occurring radioactivity were identified. The counting systems used are briefly described. Technical problems encountered, results and conclusions are discussed

  14. Evaluation of body composition and nitrogen content of renal patients on chronic dialysis as determined by total body neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Brennan, B.L.; Yasumura, S.; Vartsky, D.; Vaswani, A.N.; Ellis, K.J.

    1983-01-01

    Total body protein (nitrogen), body cell mass (potassium), fat, and water were measured in 15 renal patients on maintenance hemodialysis (MHD). Total body nitrogen was measured by means of prompt γ neutron activation analysis; total body water was determined with tritium labeled water; total body potassium was measured by whole body counting. The extracellular water was determined by a technique utilizing the measurement of total body chloride and plasma chloride. When compared with corresponding values of a control group of the same age, sex, and height, the protein content, body cell mass, and total body fat of the MHD patients were within the normal range. The only significant change was an increase in the extracellular water/body cell mass ratio in the male MHD patients compared to the control. The lack of significant difference of the nitrogen values of the MHD patients compared to matched controls suggests that dialysis minimizes any residual effects of uremic toxicity or protein-calorie malnutrition. These findings further suggest that there is a need to reevaluate the traditional anthropometric and biochemical standards of nutritional status for MHD patients. It was concluded that it is particularly important to measure protein stores of MHD patients with low protein intake to ascertain nutritional status. Finally, in vivo measurement of total body nitrogen and potassium for determination of body composition provides a simple, direct, and accurate assessment of the nutritional status of MHD patients

  15. Use of total body electrical conductivity (TOBEC) to determine total body water

    International Nuclear Information System (INIS)

    Cochran, W.; Wong, W.; Sheng, H.P.; Klein, P.; Klish, W.

    1986-01-01

    Total body electrical conductivity (TOBEC) has been introduced as a safe and rapid method to estimate body composition in infants and adults. Recently, a second generation instrument that operates in a scanning mode has been developed. A study was undertaken to calibrate this new instrument and to assess the feasibility of its use in estimating total body water. Six healthy adults, 3 males and 3 females, ranging in age from 25 to 57 years, and in weight from 43.3 to 104.7 kg were analyzed. Simultaneously, determinations of total body water were made by standard dilutional techniques using H 2 18 O. A baseline plasma sample was obtained and 60 mg 18 O/kg was given orally as H 2 18 O. Five hr later, a postdose plasma sample was obtained. The 18 O/ 16 O ratio in the plasma samples was determined as CO 2 by gas-isotope-ratio mass spectrometry and used to calculate the H 2 18 O volume of distribution. The total body water values ranged from 26.35 to 58.02 and represented 51 to 58% of body weight. There was good linear correlation between the total body water measurement and its phase average (TOBEC number) with a linear correlation coefficient of 0.998. The standard error of the estimate was 0.98. In addition to estimating fat and fat-free mass, the TOBEC method also estimates total body water with excellent correlation to physical dilutions methods

  16. Whole-body counting 1990

    International Nuclear Information System (INIS)

    Strand, P.; Selnaes, T.D.

    1990-01-01

    In order to determine the doses from radiocesium in foods after the Chernobyl accident, four groups were chosen in 1987. Two groups, presumed to have a large consumption of food items with a high radiocesium content, were selected. These were Lapp reindeer breeders from central parts of Norway, and hunters a.o. from the municipality of Oeystre Slidre. Two other groups were randomly selected, one from the municipality of Sel, and one from Oslo. The persons in these two groups were presumed to have an average diet. The fall-out in Sel was fairly large (100 kBq/m 2 ), whereas in Oslo the fall-out level was low (2 kBq/m 2 ). The persons in each group were monitored once a year with whole-body counters, and in connection with these countings dietary surveys were preformed. In 1990 the Sel-group and the Lapps in central parts of Norway were followed. Average whole-body activity in each group is compared to earlier years's results, and an average yearly effective dose equivalent is computed. The Sel-group has an average whole-body activity of 2800 Bq for men, and 690 Bq for women. Compared to earlier years, there is a steady but slow decrease in whole-body activities. Yearly dose is calculated to 0.06 mSv for 1990. The Lapps in central parts of Norway have an average whole-body content of 23800 Bq for men and 13600 Bq for women. This results in an average yearly dose of 0.9 mSv for the individuals in the group. Compared to earlier years, the Lapp group show a decrease in whole-body contents since 1988. This decrease is larger among men than women. 5 refs., 8 figs., 6 tabs

  17. Whole-body counting installation for assessment of internal contamination in workers

    International Nuclear Information System (INIS)

    Oliveira, C.A.N.; Cunha, P.G.; Lipsztein, J.L.; Bertelli, L.N.; Fonseca, A.M.G.; Ramalho, A.T.

    1985-01-01

    A whole-body counting installation for assessment of internal contamination in workers has recently been added to the Bioassay Division of the Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (IRD/CNEN). For the last two years the laboratory has been monitoring personnel involved in uranium mining and milling activities, monazite industry workers and nuclear medicine staff dealing with iodine-131 and technetium-99. Uptakes of radionuclides by the different organs and also dose equivalents are evaluated through the use of mathematical models. The IRD whole-body counter unit was specially designed to detect a variety of internally deposited radionuclides which emit photons in the energy range of 15 keV to 3 MeV. It consists of a monitoring room (2.5x2.5x2.5 m internal dimension), with 0.15 m thick steel walls, internally lined with 0.3 cm lead, 0.15 cm cadmium and 0.05 cm thick copper sheets. The facility is equipped with three different size NaI(T1) detectors and three 12.7 cm diameter phoswich detectors. (author)

  18. Theoretical assessment of whole body counting performances using numerical phantoms of different gender and sizes.

    Science.gov (United States)

    Marzocchi, O; Breustedt, B; Mostacci, D; Zankl, M; Urban, M

    2011-03-01

    A goal of whole body counting (WBC) is the estimation of the total body burden of radionuclides disregarding the actual position within the body. To achieve the goal, the detectors need to be placed in regions where the photon flux is as independent as possible from the distribution of the source. At the same time, the detectors need high photon fluxes in order to achieve better efficiency and lower minimum detectable activities. This work presents a method able to define the layout of new WBC systems and to study the behaviour of existing ones using both detection efficiency and its dependence on the position of the source within the body of computational phantoms.

  19. Theoretical assessment of whole body counting performances using numerical phantoms of different gender and sizes

    International Nuclear Information System (INIS)

    Marzocchi, O.; Breustedt, B.; Mostacci, D.; Zankl, M.; Urban, M.

    2011-01-01

    A goal of whole body counting (WBC) is the estimation of the total body burden of radionuclides disregarding the actual position within the body. To achieve the goal, the detectors need to be placed in regions where the photon flux is as independent as possible from the distribution of the source. At the same time, the detectors need high photon fluxes in order to achieve better efficiency and lower minimum detectable activities. This work presents a method able to define the layout of new WBC systems and to study the behaviour of existing ones using both detection efficiency and its dependence on the position of the source within the body of computational phantoms. (authors)

  20. Correlation between total lymphocyte count, hemoglobin, hematocrit and CD4 count in HIV patients in Nigeria.

    Science.gov (United States)

    Emuchay, Charles Iheanyichi; Okeniyi, Shemaiah Olufemi; Okeniyi, Joshua Olusegun

    2014-04-01

    The expensive and technology limited setting of CD4 count testing is a major setback to the initiation of HAART in a resource limited country like Nigeria. Simple and inexpensive tools such as Hemoglobin (Hb) measurement and Total Lymphocyte Count (TLC) are recommended as substitute marker. In order to assess the correlations of these parameters with CD4 count, 100 "apparently healthy" male volunteers tested HIV positive aged ≥ 20 years but ≤ 40 years were recruited and from whom Hb, Hct, TLC and CD4 count were obtained. The correlation coefficients, R, the Nash-Sutcliffe Coefficient of Efficiency (CoE) and the p-values of the ANOVA model of Hb, Hct and TLC with CD4 count were assessed. The assessments show that there is no significant relationship of any of these parameters with CD4 count and the correlation coefficients are very weak. This study shows that Hb, Hct and TLC cannot be substitute for CD4 count as this might lead to certain individuals' deprivation of required treatment.

  1. Total-body sodium and sodium excess

    International Nuclear Information System (INIS)

    Aloia, J.F.; Cohn, S.H.; Abesamis, C.; Babu, T.; Zanzi, I.; Ellis, K.

    1980-01-01

    Total-body levels of sodium (TBNa), chlorine (TBCI), calcium (TBCa), and potassium (TBK) were measured by neutron activation and analysis of results by whole body counting in 66 postmenopausal women. The relationship between TBNa, and TBCl, TBK, and TBCa on the one hand, and height and weight on the other, were found to compare with those previously reported. The hypothesis that TBNa and TBCl are distributed normally could not be rejected. The sodium excess (Na/sub es/) is defined as the sodium that is present in excess of that associated with the extracellular fluid (chlorine) space; the Na/sub es/ approximates nonexchangeable bone sodium. In these 66 postmenopausal women, and in patients with different endocrinopathies previously described, the values on Na/sub es/ did not differ from the normal values except in the thyrotoxicosis patients, where they were decreased. A close relationship between Na/sub es/ and TBCa was maintained in the endocrinopathies studied. This relationship was found in conditions accompanied by either an increment or a loss of skeletal mass. It appears that the NA/sub es/ value is primarily dependent upon the calcium content of bone

  2. Nuclear chemistry counting facilities: requirements definition

    International Nuclear Information System (INIS)

    O'Brien, D.W.; Baker, J.

    1979-01-01

    In an effort to upgrade outdated instrumentation and to take advantage of current and imminent technologies the Nuclear Chemistry Division at Lawrence Livermore Laboratory is about to undertake a major upgrade of their low level radiation counting and analysis facilities. It is expected that such a project will make a more coordinated data acquisition and data processing system, reduce manual data handling operations and speed up data processing throughput. Before taking on a systems design it is appropriate to establish a definition of the requirements of the facilities. This report examines why such a project is necessary in the context of the current and projected operations, needs, problems, risks and costs. The authors also address a functional specification as a prelude to a system design and the design constraints implicit in the systems implementation. Technical, operational and economic assessments establish necessary boundary conditions for this discussion. This report also establishes the environment in which the requirements definition may be considered valid. The validity of these analyses is contingent on known and projected technical, scientific and political conditions

  3. Association between lamellar body count and respiratory distress in neonates

    International Nuclear Information System (INIS)

    Bahasadri, Shoreh; Changizi, Nasrin

    2005-01-01

    Assessment of fetal lung maturity by a simple and rapid test has a pivotal role in obstetric managements. Lack of modern laboratory techniques in our country made US investigate whether lamellar body count (Lb) can be applied efficiently in the evaluation of fetal lung maturity. Lamellar body count was assessed in 104 un spun amniotic fluid samples taken from pregnant women admitted at A kbar Aba di Hospital, Tehran, Iran between May 2003 and November 2003 whose fetuses were at risk for respiratory distress syndrome (RDS). Cut-off points for LBC were determined to evaluate the risk of RDS. Standard clinical and radiographic criteria were used to diagnose RDS. An LBC of less than 10,000 was 99.1% specific for lung immaturity (positive predictive value = 99.1%, negative predictive value = 83.5%). The LBCs of greater than 45,000 eliminates RDS (negative predictive value = 98.9%). Lamellar body count is an easy, rapid and cost-effective test to assess fetal lung maturity in high-risk fetuses. Using the cut-off points of 10,000 and 45,000, LBC can serve as the first screening test of fetal lung maturity. (author)

  4. Use of the total motile sperm count to predict total fertilization failure in in vitro fertilization

    NARCIS (Netherlands)

    Repping, Sjoerd; van Weert, Janne-Meije; Mol, Ben W. J.; de Vries, Jan W. A.; van der Veen, Fulco

    2002-01-01

    Objective: To evaluate the capacity of baseline characteristics and total motile sperm count (TMC) to predict total fertilization failure (TIFF) in patients undergoing IVF. Design: Retrospective cohort study. Setting: University hospital. Patient(s): Eight hundred ninety-two couples with a total of

  5. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu...

  6. Revisiting Biomarkers of Total-Body and Partial-Body Exposure in a Baboon Model of Irradiation.

    Directory of Open Access Journals (Sweden)

    Marco Valente

    Full Text Available In case of a mass casualty radiation event, there is a need to distinguish total-body irradiation (TBI and partial-body irradiation (PBI to concentrate overwhelmed medical resources to the individuals that would develop an acute radiation syndrome (ARS and need hematologic support (i.e., mostly TBI victims. To improve the identification and medical care of TBI versus PBI individuals, reliable biomarkers of exposure could be very useful. To investigate this issue, pairs of baboons (n = 18 were exposed to different situations of TBI and PBI corresponding to an equivalent of either 5 Gy 60Co gamma irradiation (5 Gy TBI; 7.5 Gy left hemibody/2.5 right hemibody TBI; 5.55 Gy 90% PBI; 6.25 Gy 80% PBI; 10 Gy 50% PBI, 15 Gy 30% PBI or 2.5 Gy (2.5 Gy TBI; 5 Gy 50% PBI. More than fifty parameters were evaluated before and after irradiation at several time points up to 200 days. A partial least square discriminant analysis showed a good distinction of TBI from PBI situations that were equivalent to 5 Gy. Furthermore, all the animals were pooled in two groups, TBI (n = 6 and PBI (n = 12, for comparison using a logistic regression and a non parametric statistical test. Nine plasmatic biochemical markers and most of hematological parameters turned out to discriminate between TBI and PBI animals during the prodromal phase and the manifest illness phase. The most significant biomarkers were aspartate aminotransferase, creatine kinase, lactico dehydrogenase, urea, Flt3-ligand, iron, C-reactive protein, absolute neutrophil count and neutrophil-to-lymphocyte ratio for the early period, and Flt3-ligand, iron, platelet count, hemoglobin, monocyte count, absolute neutrophil count and neutrophil-to-lymphocyte ratio for the ARS phase. These results suggest that heterogeneity could be distinguished within a range of 2.5 to 5 Gy TBI.

  7. Monte Carlo efficiency calibration of a neutron generator-based total-body irradiator

    International Nuclear Information System (INIS)

    Shypailo, R.J.; Ellis, K.J.

    2009-01-01

    Many body composition measurement systems are calibrated against a single-sized reference phantom. Prompt-gamma neutron activation (PGNA) provides the only direct measure of total body nitrogen (TBN), an index of the body's lean tissue mass. In PGNA systems, body size influences neutron flux attenuation, induced gamma signal distribution, and counting efficiency. Thus, calibration based on a single-sized phantom could result in inaccurate TBN values. We used Monte Carlo simulations (MCNP-5; Los Alamos National Laboratory) in order to map a system's response to the range of body weights (65-160 kg) and body fat distributions (25-60%) in obese humans. Calibration curves were constructed to derive body-size correction factors relative to a standard reference phantom, providing customized adjustments to account for differences in body habitus of obese adults. The use of MCNP-generated calibration curves should allow for a better estimate of the true changes in lean tissue mass that many occur during intervention programs focused only on weight loss. (author)

  8. Experience with a mobile whole body counting screening program at Ontario Hydro

    International Nuclear Information System (INIS)

    Wong, K.Y.

    1976-01-01

    A whole-body counting program using a trailer-mounted counter has been in service in Ontario Hydro since 1972 to monitor routinely internal uptakes of radionuclides by nuclear station employees. The philosophy and objectives of the program are discussed; equipment and calibration procedures are described, and experience over the past two and a half years is reviewed. The procedures to minimize the effects of external contamination, a problem commonly encountered in whole-body counting, are described. (auth)

  9. Short communication: Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count.

    Science.gov (United States)

    Koop, G; Dik, N; Nielen, M; Lipman, L J A

    2010-06-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC (Fossomatic 5000, Foss, Hillerød, Denmark) and TBC (BactoScan FC 150, Foss) were measured. Staphylococcal count was correlated to SCC (r=0.40), TBC (r=0.51), and SPC (r=0.53). Coliform count was correlated to TBC (r=0.33), but not to any of the other variables. Staphylococcus aureus did not correlate to SCC. The contribution of the staphylococcal count to the SPC was 31%, whereas the coliform count comprised only 1% of the SPC. The agreement of the repeated measurements was low. This study indicates that staphylococci in goat bulk milk are related to SCC and make a significant contribution to SPC. Because of the high variation in bacterial counts, repeated sampling is necessary to draw valid conclusions from bulk milk culturing. 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. Measurement of whole body cellular and collagen nitrogen, potassium, and other elements by neutron activation and whole body counting

    International Nuclear Information System (INIS)

    James, H.M.; Fabricius, P.J.; Dykes, P.W.

    1987-01-01

    Whole body nitrogen can be measured by neutron activation analysis with an acceptable radiation dose; it is an index of body protein which, in normal subjects, is 65% cellular protein and 35% extracellular connective collagen. Whole body potassium can be measured by whole body counting without irradiating the subject; it is an index of body cell mass. We measured whole body nitrogen, potassium, extracellular water, intracellular water, and fat-folds. The differences between 37 malnourished patients and five normal subjects suggested that the patients had 9 kg less cell mass than normal, but no difference in extracellular mass. Measurements were made on eight patients before and after 14 days of total parenteral nutrition; balance of nitrogen intake and excretion also was measured. The changes were consistent with mean increases of 3 kg of cellular mass and 3 kg of fat with no change of extracellular mass. The accuracy and sensitivity of the whole body measurements need further confirmation for use in patients with changing body composition. Where tissue wasting is largely from the cellular compartment, potassium could be a more sensitive index of wasting than nitrogen. Multielement analysis of nitrogen, potassium, chlorine, and carbon will probably be valuable in elucidating body composition in malnutrition

  11. Marrow toxicity of fractionated vs. single dose total body irradiation is identical in a canine model

    International Nuclear Information System (INIS)

    Storb, R.; Raff, R.F.; Graham, T.; Appelbaum, F.R.; Deeg, H.J.; Schuening, F.G.; Shulman, H.; Pepe, M.

    1993-01-01

    The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing 60 Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionated total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs

  12. Measurement of Organ Uptake by Whole-Body Counting

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1970-01-01

    This paper reviews methods for the measurement of radioactivity in body organs based on whole-body radioactivity measurements. Such measurements can of course only be used to measure radioactivity in a body organ when the radioactivity is exclusively localized in the organ or when the ratio of radioactivity in the organ to that in the whole body is known from other sources of information. They find particular applications, however, when the organ is so widely dispersed throughout the body that more localized measurement is impossible. Examples of situations in which whole-body radioactivity measurements have been used in this way are cited. The more important techniques used for such measurements are described and their respective advantages and disadvantages indicated. The importance of uniformity of counting efficiency with position of source throughout the body is stressed. Simple systems incorporating sodium iodide crystal scintillation detectors are shown to combine satisfactory sensitivity and uniformity of efficiency for clinical measurements of radioactivity in body organs and have the additional advantage that they can be readily adapted for profile scanning. Systems incorporating plastic or liquid scintillation detectors are less convenient in this respect. (author)

  13. Evaluation of misplaced event count rate using a scintillation camera

    International Nuclear Information System (INIS)

    Yanagimoto, Shin-ichi; Tomomitsu, Tatsushi; Muranaka, Akira

    1985-01-01

    Misplaced event count rates were evaluated using an acryl scatter body of various thickness and a gamma camera. The count rate in the region of interest (ROI) within the camera view field, which was thought to represent part of the misplaced event count rate, increased as the thickness of the scatter body was increased to 5 cm, followed by a steep decline in the count rate. On the other hand, the ratio of the count rate in the ROI to the total count rate continuously increased as the thickness of the scatter body was increased. As the thickness of the scatter body was increased, the count rates increased, and the increments of increase were greater in the lower energy region of the photopeak than in the higher energy region. In ranges energy other than the photopeak, the influence of the scatter body on the count rate in the ROI was the greatest at 76 keV, which was the lowest energy we examined. (author)

  14. FY16 ISCP Nuclear Counting Facility Hardware Expansion Summary

    Energy Technology Data Exchange (ETDEWEB)

    Church, Jennifer A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kashgarian, Michaele [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wooddy, Todd [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haslett, Bob [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Torretto, Phil [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-09-15

    Hardware expansion and detector calibrations were the focus of FY 16 ISCP efforts in the Nuclear Counting Facility. Work focused on four main objectives: 1) Installation, calibration, and validation of 4 additional HPGe gamma spectrometry systems; including two Low Energy Photon Spectrometers (LEPS). 2) Re-Calibration and validation of 3 previously installed gamma-ray detectors, 3) Integration of the new systems into the NCF IT infrastructure, and 4) QA/QC and maintenance of current detector systems.

  15. FY16 ISCP Nuclear Counting Facility Hardware Expansion Summary

    International Nuclear Information System (INIS)

    Church, Jennifer A.; Kashgarian, Michaele; Wooddy, Todd; Haslett, Bob; Torretto, Phil

    2016-01-01

    Hardware expansion and detector calibrations were the focus of FY 16 ISCP efforts in the Nuclear Counting Facility. Work focused on four main objectives: 1) Installation, calibration, and validation of 4 additional HPGe gamma spectrometry systems; including two Low Energy Photon Spectrometers (LEPS). 2) Re-Calibration and validation of 3 previously installed gamma-ray detectors, 3) Integration of the new systems into the NCF IT infrastructure, and 4) QA/QC and maintenance of current detector systems.

  16. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu......A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK......). These measurements were compared with bioimpedance analysis (BIA) by applying 11 predictive BIA equations published in the literature. Predictive equations for the present study population were developed, with the use of fat-free mass (FFM) as assessed by TBK and DXA as references in multiple regression analysis....... The results of the BIA equations varied widely; FFM was generally overestimated by BIA as compared with DXA and TBK before and after weight loss. During weight loss, the FFM did not change, as estimated by DXA (1.3 +/- 2.3 kg, p > 0.05) and TBK (0.9 +/- 2.9 kg, p > 0.05). The recorded change in impedance (R...

  17. Biochemical and hematological indicators in model of total body irradiation

    International Nuclear Information System (INIS)

    Dubner, D; Gisone, P.; Perez, M.R.; Barboza, M.; Luchetta, P.; Longoni, H.; Sorrentino, M.; Robison, A.

    1998-01-01

    With the purpose of evaluating the applicability of several biological indicators in accidental overexposures a study was carried out in 20 patients undergoing therapeutical total body irradiation (TBI). The following parameters were evaluated: a) Oxidative stress indicators: erythrocyte superoxide dismutase (SOD) and catalase activity (CAT), lipo peroxyde levels (TBARS) and total plasma antioxidant activity (TAA). b) Haematological indicators: reticulocyte maturity index (RMI) and charges in lymphocyte subpopulations. Non significant changes in SOD and CAT activity were observed. Significant higher TBARS levels were found in patients with unfavorable post-BTM course without any significant correlation with TAA. RMI decreased early and dropped to zero in most of the patients and rose several days prior to reticulocyte, neutrophils and platelets counts. A significant decrease in absolute counts of all lymphocyte subpopulations was observed during TBI, particularly for B lymphocytes. A subpopulation of natural killer (NK) cells (CD16+/ CD 56 +) showed a relative higher radioresistance. Cytotoxic activity was significantly decreased after TBI. These data suggest that TBARS could provide an useful evolutive indicator in accidental over exposure d patients and RMI is an early indicator of bone marrow recovery after radioinduced aplasia. The implications of the different radiosensitivities within the NK subsets remains unanswered. (author) [es

  18. Whole-body counting of Fukushima residents after the TEPCO Fukushima Daiichi Nuclear Power Station accident

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Takumaro; Takada, Chie; Nakagawa, Takahiro; Nakai, Katsuta; Kurihara, Osamu; Tsujimura, Norio; Furuta, Sadaaki [Japan Atomic Energy Agency, Nuclear Fuel Cycle Engineering Laboratories, Tokai, Ibaraki (Japan); Ohi, Yoshihiro; Murayama, Takashi; Suzuki, Takashi [Japan Atomic Energy Agency, Nuclear Science Research Institute, Tokai, Ibaraki (Japan); Uezu, Yasuhiro [Japan Atomic Energy Agency, Fukushima Environmental Safety Center, Fukushima, Fukushima (Japan)

    2012-11-15

    At the request of the Fukushima government, the Japan Atomic Energy Agency (JAEA) started whole-body counting of residents on July 11, 2011, to assess radiation exposure after the TEPCO Fukushima Daiichi Nuclear Power Station accident. JAEA has examined residents in Iitate, Kawamata, Namie, and eight other local communities. The measurement capacity of the whole-body counting device is approximately 100 persons per day, and the total number of people to measure reached 9,927 by the end of January 2012. Two types of whole-body counter (WBC), each of which has two large-sized NaI(Tl) detectors, were used to perform the measurements. Physical phantoms (a Canberra RMC-II transfer phantom or a water-filled block phantom developed by JAEA) were used to perform the efficiency calibration of the WBCs, and results of this calibration were verified by comparing them with different-sized BOttle Mannequin ABsorber (BOMAB) phantoms imitating an adult male, a 10-year-old child, and a 4-year-old child. Short half-life radionuclides (e.g., {sup 131}I) originating from the accident were not detected in the present work, because the measurements were made starting four months after the accident. These measurements showed that about 80% of the residents were below a minimum detectable amount (MDA) of the measured radionuclides in the whole-body content. No artificial nuclides other than {sup 134}Cs and {sup 137}Cs were detected in the present whole-body counting. The maximum whole-body content of radiocesium ({sup 134}Cs and {sup 137}Cs in total) was 2.7 kBq for children (< 8 years old) and 14 kBq for adults. The radioactivity ratio ({sup 137}Cs/{sup 134}Cs) was estimated to be from 1.12 to 1.26. An acute intake scenario via inhalation of radiocesium was assumed in the present dose estimation for all the residents who were measured by the end of January 2012. The committed effective dose (CED) to 99.8% of the residents was found to be below 1 mSv. There were only 25 subjects with a

  19. Immature germ cells in semen - correlation with total sperm count and sperm motility.

    Science.gov (United States)

    Patil, Priya S; Humbarwadi, Rajendra S; Patil, Ashalata D; Gune, Anita R

    2013-07-01

    Current data regarding infertility suggests that male factor contributes up to 30% of the total cases of infertility. Semen analysis reveals the presence of spermatozoa as well as a number of non-sperm cells, presently being mentioned in routine semen report as "round cells" without further differentiating them into leucocytes or immature germ cells. The aim of this work was to study a simple, cost-effective, and convenient method for differentiating the round cells in semen into immature germ cells and leucocytes and correlating them with total sperm counts and motility. Semen samples from 120 males, who had come for investigation for infertility, were collected, semen parameters recorded, and stained smears studied for different round cells. Statistical analysis of the data was done to correlate total sperm counts and sperm motility with the occurrence of immature germ cells and leucocytes. The average shedding of immature germ cells in different groups with normal and low sperm counts was compared. The clinical significance of "round cells" in semen and their differentiation into leucocytes and immature germ cells are discussed. Round cells in semen can be differentiated into immature germ cells and leucocytes using simple staining methods. The differential counts mentioned in a semen report give valuable and clinically relevant information. In this study, we observed a negative correlation between total count and immature germ cells, as well as sperm motility and shedding of immature germ cells. The latter was statistically significant with a P value 0.000.

  20. Total body irradiation

    International Nuclear Information System (INIS)

    Novack, D.H.; Kiley, J.P.

    1987-01-01

    The multitude of papers and conferences in recent years on the use of very large megavoltage radiation fields indicates an increased interest in total body, hemibody, and total nodal radiotherapy for various clinical situations. These include high dose total body irradiation (TBI) to destroy the bone marrow and leukemic cells and provide immunosuppression prior to a bone marrow transplant, high dose total lymphoid irradiation (TLI) prior to bone marrow transplantation in severe aplastic anemia, low dose TBI in the treatment of lymphocytic leukemias or lymphomas, and hemibody irradiation (HBI) in the treatment of advanced multiple myeloma. Although accurate provision of a specific dose and the desired degree of dose homogeneity are two of the physicist's major considerations for all radiotherapy techniques, these tasks are even more demanding for large field radiotherapy. Because most large field radiotherapy is done at an extended distance for complex patient geometries, basic dosimetry data measured at the standard distance (isocenter) must be verified or supplemented. This paper discusses some of the special dosimetric problems of large field radiotherapy, with specific examples given of the dosimetry of the TBI program for bone marrow transplant at the authors' hospital

  1. Corrections of the whole body counting for various measurement geometries

    International Nuclear Information System (INIS)

    Fueloep, M.; Ragan, P.; Lahham, A.

    1996-01-01

    A simple method was suggested for making corrections during the calibration of HPGe detectors employed for the whole-body counting of humans ranging from infants to adults. The results obtained by calculations were verified by using phantoms. (P.A.). 1 tab., 5 figs., 3 refs

  2. Cataract incidence after total-body irradiation

    International Nuclear Information System (INIS)

    Zierhut, D.; Lohr, F.; Schraube, P.; Huber, P.; Haas, R.; Hunstein, W.; Wannenmacher, M.

    1997-01-01

    Purpose: Aim of this retrospective study was to evaluate cataract incidence in a homogeneous group of patients after total-body irradiation followed by autologous bone marrow transplantation or peripheral blood stem cell transplantation. Method and Materials: Between 11/1982 and 6/1994 in total 260 patients received in our hospital total-body irradiation for treatment of haematological malignancy. In 1996-96 patients out of these 260 patients were still alive. 85 from these still living patients (52 men, 33 women) answered evaluable on a questionnaire and could be examined ophthalmologically. Median age of these patients was 38,5 years (15 - 59 years) at time of total-body irradiation. Radiotherapy was applied as hyperfractionated total-body irradiation with a median dose of 14,4 Gy in 12 fractions over 4 days. Minimum time between fractions was 4 hours, photons with a energy of 23 MeV were used, and the dose rate was 7 - 18 cGy/min. Results: Median follow-up is now 5,8 years (1,7 - 13 years). Cataract occurred in (28(85)) patients after a median time of 47 months (1 - 104 months). In 6 out of these 28 patients who developed a cataract, surgery of the cataract was performed. Whole-brain irradiation prior to total-body irradiation was more often in the group of patients developing a cataract (14,3%) vs. 10,7% in the group of patients without cataract. Conclusion: Cataract is a common side effect of total-body irradiation. Cataract incidence found in our patients is comparable to results of other centres using a fractionated regimen for total-body irradiation. The hyperfractionated regimen used in our hospital does obviously not result in a even lower cataract incidence. In contrast to acute and late toxicity in other organ/organsystems, hyperfractionation of total-body irradiation does not further reduce toxicity for the eye-lens. Dose rate may have more influence on cataract incidence

  3. Validation parameters of instrumental method for determination of total bacterial count in milk

    Directory of Open Access Journals (Sweden)

    Nataša Mikulec

    2004-10-01

    Full Text Available The method of flow citometry as rapid, instrumental and routine microbiological method is used for determination of total bacterial count in milk. The results of flow citometry are expressed as individual bacterial cells count. Problems regarding the interpretation of the results of total bacterial count can be avoided by transformation of the results of flow citometry method onto the scale of reference method (HRN ISO 6610:2001.. The method of flow citometry, like any analitycal method, according to the HRN EN ISO/IEC 17025:2000 standard, requires validation and verification. This paper describes parameters of validation: accuracy, precision, specificity, range, robustness and measuring uncertainty for the method of flow citometry.

  4. Effects of Agave tequilana fructans with different degree of polymerization profiles on the body weight, blood lipids and count of fecal Lactobacilli/Bifidobacteria in obese mice.

    Science.gov (United States)

    Márquez-Aguirre, Ana Laura; Camacho-Ruiz, Rosa Maria; Arriaga-Alba, Myriam; Padilla-Camberos, Eduardo; Kirchmayr, Manuel Reinhart; Blasco, José Luis; González-Avila, Marisela

    2013-08-01

    Fructans are dietary fibers with beneficial effects on the gastrointestinal physiology and offer a promising approach for the treatment of some metabolic disorders associated with obesity. In vitro and in vivo studies were developed to test the safety of fructans obtained from Agave tequilana Weber var. azul. Additionally, an in vivo experiment using a diet-induced obesity model was performed to compare the effect of agave fructans with different degree of polymerization (DP) profiles: agave fructans with DP > 10 (LcF), agave FOS with DP agave fructans with and without demineralization (dTF, TF) versus commercial chicory fructans (OraftiSynergy1™) on the body weight change, fat, total cholesterol, triglycerides and count of fecal Lactobacillus spp. and Bifidobacterium spp. Results showed that A. tequilana fructans were not mutagenic and were safe even at a dose of 5 g per kg b.w. Obese mice that received ScF showed a significant decrease in body weight gain, fat tissue and total cholesterol without increasing the count of fecal Bifidobacteria. Whereas, obese mice that received LcF and TF showed decreased triglycerides and an increased count of fecal Bifidobacteria. Interestingly, although obese mice that received dTF did not show changes in body weight gain, fat tissue, total cholesterol or triglycerides, they showed an increase in the count of Bifidobacteria. These results demonstrate that both the degree of polymerization and the demineralization process can influence the biological activity of agave fructans.

  5. Impact of body habitus on quantitative and qualitative image quality in whole-body FDG-PET

    Energy Technology Data Exchange (ETDEWEB)

    Tatsumi, Mitsuaki; Clark, Paul A.; Nakamoto, Yuji; Wahl, Richard L. [Division of Nuclear Medicine, Department of Radiology, The Johns Hopkins Medical Institutions, 601 N. Caroline St., Rm 3223, Baltimore, MD 21287-0817 (United States)

    2003-01-01

    Obtaining consistent high image quality is desirable for clinical positron emission tomography (PET). Body morphology may impact image quality. The purpose of this study was to define the average and the range of body sizes in patients undergoing tumor PET studies in our center and to determine how the body habitus affects the statistical and visual quality of PET images. Height, weight, body surface area (BSA), and body mass index (BMI) were determined in 101 male and 101 female patients (group 1) referred for clinical PET. The summed total counts from three consecutive transaxial slices on non-attenuation-corrected (NAC) 2D fluorine-18 fluorodeoxyglucose (FDG) PET images, which included the largest liver section and no lesions, were determined and compared with body morphology and injected doses (ID) in a representative group of 30 male and 30 female patients (group 2) spanning a range of body morphologies. The visual quality of images was also evaluated using a scoring system by three readers. The average height, weight, and BSA were greater in male than in female patients, but the average BMI was not different between them in group 1. The largest value of weight or BMI was more than four times the smallest value in female patients. The total true counts were best correlated with ID/weight (mCi/kg) in group 2 (r=0.929, P<0.0001). Intermediate to high total counts (930,000 or more) corresponded to ID/weight of 0.22 or higher. The average visual score was positively correlated with the total counts ({rho}=0.63, P<0.0001) and with ID/weight ({rho}=0.68, P<0.0001) on NAC images. The image quality in 22 (84.6%) of 26 patients with intermediate to high total counts was adequate to good, whereas that in 21 (61.8%) of 34 patients with lower total counts was suboptimal. A wide variety of body morphologies was observed in patients referred for clinical FDG-PET tumor studies in our center. The total counts and average image visual score were negatively correlated with

  6. White Blood Cell Count and Total and Cause-Specific Mortality in the Women's Health Initiative.

    Science.gov (United States)

    Kabat, Geoffrey C; Kim, Mimi Y; Manson, JoAnn E; Lessin, Lawrence; Lin, Juan; Wassertheil-Smoller, Sylvia; Rohan, Thomas E

    2017-07-01

    White blood cell (WBC) count appears to predict total mortality and coronary heart disease (CHD) mortality, but it is unclear to what extent the association reflects confounding by smoking, underlying illness, or comorbid conditions. We used data from the Women's Health Initiative to examine the associations of WBC count with total mortality, CHD mortality, and cancer mortality. WBC count was measured at baseline in 160,117 postmenopausal women and again in year 3 in 74,375 participants. Participants were followed for a mean of 16 years. Cox proportional hazards models were used to estimate the relative mortality hazards associated with deciles of baseline WBC count and of the mean of baseline + year 3 WBC count. High deciles of both baseline and mean WBC count were positively associated with total mortality and CHD mortality, whereas the association with cancer mortality was weaker. The association of WBC count with mortality was independent of smoking and did not appear to be influenced by previous disease history. The potential clinical utility of this common laboratory test in predicting mortality risk warrants further study. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Propidium iodide (PI) stains Nissl bodies and may serve as a quick marker for total neuronal cell count.

    Science.gov (United States)

    Niu, Junfei; Li, Chunman; Wu, Haihui; Feng, Xianling; Su, Qingning; Li, Shihe; Zhang, Lihong; Yew, David Tai Wai; Cho, Eric Yu Pang; Sha, Ou

    2015-03-01

    Propidium iodide (PI) reacts with both DNA and RNA and is a commonly used fluorescent reagent for nucleic acid staining. The aim of the study was to compare the cellular staining patterns of PI with that of Nissl staining in rat nervous tissues and to report a modified staining method that selectively labels Nissl bodies in neurons. Cryosections and paraffin sections of different tissues of normal Sprague-Dawley rats, including trigeminal ganglia, dorsal root ganglia, spinal cord, liver, and small intestine, were stained by either PI or the hematoxylin and eosin method. Some sections were treated with RNase or DNase before the above staining, and some were double stained with PI and a Nissl stain. The sections were observed by light, fluorescence or confocal microscopy. Results showed strong PI signals detected as patterns of granules in the neuronal cytoplasm of all nervous tissues, whereas the staining of neuronal nuclei was weaker. In contrast, nuclei of neuroglial cells were strongly stained by PI, while the cytoplasm was not obviously stained. Pretreatment of the neural tissue with RNase abolished the PI signals. Furthermore, the PI positive granules in neuronal cytoplasm co-localized with Nissl bodies stained by the fluorescent Nissl stain. When the tissue was pretreated with DNase, PI only stained the cytoplasmic granules of neurons, but not that of glial cells. Our results show that PI stains Nissl bodies and may serve as an economical and convenient neuron marker for neuronal cell counting when specific neural markers such as antibodies are not readily available. Copyright © 2015. Published by Elsevier GmbH.

  8. Investigation into the relationship between body surface area and total body potassium using Monte Carlo and measurement

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, J.A. [Medical Physics and Imaging, Queen Elizabeth Hospital, Birmingham (United Kingdom)]. E-mail: jane.rogers@university-b.wmids.nhs.uk; Blake-James, M. [School of Physics and Astronomy, University of Birmingham, Birmingham (United Kingdom); Green, S.; Beddoe, A.H. [Medical Physics and Imaging, Queen Elizabeth Hospital, Birmingham (United Kingdom)

    2002-03-07

    The use of body surface area (BSA) as a means of indexing chemotherapy doses is widespread even though the value of this practice is uncertain. In principle, the body cell mass (BCM) more closely represents the body's metabolic size and this is investigated here as an alternative to BSA; since 98% of body potassium is intracellular the derivation of total body potassium (TBK) via the measurement of {sup 40}K in a whole body counter (WBC) will provide a useful normalizing index for metabolic size, potentially avoiding toxicity and underdosing. The Queen Elizabeth Hospital WBC has been used in this study, initially involving single geometrical phantoms and then combinations of these to simulate human body habitus. Monte Carlo N-particle (MCNP) codes were constructed to model the phantoms and simulate the measurements made in the WBC. Efficiency corrections were derived by comparing measurement and modelled data for each detector separately. A method of modelling a person in the WBC as a series of ellipsoids was developed. Twenty-four normal males and 24 females were measured for their {sup 40}K emissions. Individual MCNP codes were constructed for each volunteer and the results used in conjunction with the measurements to derive TBK, correcting for body habitus effects and detector efficiencies. An estimate of the component of error arising from sources other than counting statistics was included by analysing data from the measurement of phantoms. The total residual errors (expressed as coefficients of variation) for males and females were 10.1% and 8.5% respectively. The measurement components were determined to be 2.4% and 2.5%, implying that the biological components were 9.8% and 8.1% respectively. These results suggest that the use of BSA for indexing chemotherapy doses is likely to give rise to clinically significant under- or overdosing. (author)

  9. Total body irradiation: current indications; L`irradiation corporelle totale: les indications actuelles

    Energy Technology Data Exchange (ETDEWEB)

    Giraud, P.; Danhier, S.; Dubray, B.; Cosset, J.M. [Institut Curie, 75 - Paris (France)

    1998-05-01

    The choice of dose and fractionation for total body irradiation is made difficult by the large number of considerations to be taken into account. The outcome of bone marrow transplantation after total body irradiation can be understood in terms of tumor cell killing, engraftment, and normal tissue damage, each of these endpoints being influenced by irradiation-, disease-, transplant-, and patient- related factors. Interpretation of clinical data is further hampered by the overwhelming influence of logistic constraints, the small numbers of randomized studies, and the concomitant variations in total dose and fraction size or dose rate. So far, three cautious conclusions can be drawn in order to tentatively adapt the total body irradiation schedule to clinically-relevant situations. Firstly, the organs at risk for normal tissue damage (lung, liver, lens, kidney) are protected by delivering small doses per fraction at low dose rate. This suggests that, when toxicity is at stake (e.g. in children), fractionated irradiation should be preferred, provided that inter-fraction intervals are long enough. Secondly, fractionated irradiation should be avoided in case of T-cell depleted transplant, given the high risk of graft rejection in this setting. An alternative would be to increase total (or fractional) dose of fractionated total body irradiation, but this approach is likely to induce more normal tissue toxicity. Thirdly, clinical data have shown higher relapse rates in chronic myeloid leukemia after fractionated or low dose rate total body irradiation, suggesting that fractionated irradiation should not be recommended, unless total (or fractional) dose is increased. Total body irradiation-containing regimens, primarily cyclophosphamide / total body irradiation, are either equivalent to or better than the chemotherapy-only regimens, primarily busulfan / cyclophosphamide. Busulfan / cyclophosphamide certainly represents a reasonable alternative, especially in patients who

  10. Calibration of the Accuscan II In Vivo System for Whole Body Counting

    Energy Technology Data Exchange (ETDEWEB)

    Orval R. Perry; David L. Georgeson

    2011-08-01

    This report describes the April 2011 calibration of the Accuscan II HpGe In Vivo system for whole body counting. The source used for the calibration was a NIST traceable BOMAB manufactured by DOE as INL2006 BOMAB containing Eu-154, Eu-155, Eu-152, Sb-125 and Y-88 with energies from 27 keV to 1836 keV with a reference date of 11/29/2006. The actual usable energy range was 86.5 keV to 1597 keV on 4/21/2011. The BOMAB was constructed inside the Accuscan II counting 'tub' in the order of legs, thighs, abdomen, thorax/arms, neck, and head. Each piece was taped to the backwall of the counter. The arms were taped to the thorax. The phantom was constructed between the v-ridges on the backwall of the Accuscan II counter. The energy and efficiency calibrations were performed using the INL2006 BOMAB. The calibrations were performed with the detectors in the scanning mode. This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for whole body counting and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  11. Fractional intestinal absorption and retention of calcium measured by whole-body counting. Application of a power function model

    International Nuclear Information System (INIS)

    Pors Nielsen, S.; Baerenholdt, O.; Munck, O.

    1975-01-01

    By application of a power function model, fractional intestinal calcium absorption was investigated with a new technique involving whole-body counting after successive oral and intravenous administration of standard doses of 47 Ca. The fractional calcium retention 7 days after the oral load of 47 Ca was also measured. Fractional calcium retention averaged 30.3% in normal subjects and 11.5% in 11 patients with intestinal malabsorption. In the same groups fractional calcium absorption averaged 46.6% and 16.4%, respectively. Fractional calcium retention and intestinal calcium absorption were significantly correlated to body surface area, and there was a well-defined relation between fractional retention and absorption of calcium. These studies demonstrate that measurements of fractional retention and fractional intestinal absorption of calcium can be combined by the use of a whole-body counter, that fractional retention and intestinal absorption are proportional to total body surface area and therefore probably also to the total bone mass, and that fractional retention and absorption are so closely interrelated that frational absorption can be estimated from fractional retention with reasonable accuracy in normal subjects. (auth.)

  12. Low background germanium detectors: From environmental laboratory to underground counting facility

    Energy Technology Data Exchange (ETDEWEB)

    Ceuppens, M [Canberra Semiconductor N.V., Geel (Belgium); [Canberra Industries, Inc., Meriden (United States); Verplancke, J [Canberra Semiconductor N.V., Geel (Belgium); [Canberra Industries, Inc., Meriden (United States); Tench, O [Canberra Semiconductor N.V., Geel (Belgium); [Canberra Industries, Inc., Meriden (United States)

    1997-03-01

    Presentation and overview of different Low Level measuring systems ranging from the environmental lab to low-background detection systems and to the deep underground counting facility. Examples and performances for each of these will be given. Attention will be given to the standardised ultra low-background detectors and shields which provide excellent performance without the high cost in time and money associated with custom designed systems. (orig./DG)

  13. Low background germanium detectors: From environmental laboratory to underground counting facility

    International Nuclear Information System (INIS)

    Ceuppens, M.; Verplancke, J.; Tench, O.

    1997-01-01

    Presentation and overview of different Low Level measuring systems ranging from the environmental lab to low-background detection systems and to the deep underground counting facility. Examples and performances for each of these will be given. Attention will be given to the standardised ultra low-background detectors and shields which provide excellent performance without the high cost in time and money associated with custom designed systems. (orig./DG)

  14. Effect of warm-smoking on total microbial count of meat products

    Directory of Open Access Journals (Sweden)

    A Javadi

    2007-11-01

    Full Text Available The frankfurters are amongst the most famous and popular sausages in the world and beef and poultry meat are used in Iran for their preparation. The techniques of warm smoking at 42°c for two hours and then hot smoking together with steam cooking at 8°c for one hour are utilized in proportion of this product. In spite of its carcinogenic properties, smoke is used to create color, flavor and odor and to improve the preservative qualities of sausages. In this study, 14 sausage samples were taken from each of the stages of frankfurter production line including pre-smoking, post- warm smoking and post-hot smoking, their total microbial counts (aerobic mesophiles determined and the means of the three stages compared using the ANOVA statistical test. The results indicated that the total microbial count increased significantly (P

  15. The use of comparative 137Cs body burden estimates from environmental data/models and whole body counting to evaluate diet models for the ingestion pathway

    International Nuclear Information System (INIS)

    Robison, W.L.; Sun, C.

    1997-01-01

    Rongelap and Utirik Atolls were contaminated on 1 March 1954, by a U.S. nuclear test at Bikini Atoll code named BRAVO. The people at both atolls were removed from their atolls in the first few days after the detonation and were returned to their atolls at different times. Detailed studies have been carried out over the years by Lawrence Livermore National Laboratory (LLNL) to determine the radiological conditions at the atolls and estimate the doses to the populations. The contribution of each exposure pathway and radionuclide have been evaluated. All dose assessments show that the major potential contribution to the estimated dose is 137 Cs uptake via the terrestrial food chain. Brookhaven National Laboratory (BNL) has carried out an extensive whole body counting program at both atolls over several years to directly measure the 137 Cs body burden. Here we compare the estimates of the body burdens from the LLNL environmental method with body burdens measured by the BNL whole body counting method. The combination of the results from both methods is used to evaluate proposed diet models to establish more realistic dose assessments. Very good agreement is achieved between the two methods with a diet model that includes both local and imported foods. Other diet models greatly overestimate the body burdens (i.e., dose) observed by whole body counting. The upper 95% confidence limit of interindividual variability around the population mean value based on the environmental method is similar to that calculated from direct measurement by whole body counting. Moreover, the uncertainty in the population mean value based on the environmental method is in very good agreement with the whole body counting data. This provides additional confidence in extrapolating the estimated doses calculated by the environmental method to other islands and atolls. 46 refs., 8 figs., 5 tabs

  16. Whole-body counting in the Marshall Islands

    International Nuclear Information System (INIS)

    Sun, L.C.; Clinton, J.; Kaplan, E.; Meinhold, C.B.

    1991-01-01

    In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish 137 Cesium body contents among the Enewetak, Rongelap and Utirik populations. 137 Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. 137 Cs body burdens tended to increase with age for both sexes, and were higher in males. The average 137 Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22±4 μSv. For Utirik, the dose was 33± 3 μSv. Since 1985 the Rongelap people have been self-exiled to Mejatto. Biological elimination should have reduced their dose to virtually zero, and the measured dose was 2±2 μSv. If they had remained on Rongelap Island, the calculated dose would have been 99 μSv, which is about one-third of the background dose. 7 refs., 1 tab

  17. A preliminary study of iron absorption by whole body counting and correlation with DFO excretion

    International Nuclear Information System (INIS)

    Gupta, M.M.; Bhattacharyya, L.; Gupta, N.K.; Bhola, G.C.; Nagaratnam, A.; Manchanda, R.; Bhargva, M.; Kumar, S.

    1975-01-01

    A preliminary study of iron absorption by oral administration of 59 Fe and whole body counting was carried on a group of 16 women. The cases included 8 patients suffering from iron deficiency anaemia and various infections as well as 8 healthy controls. High iron absorption is associated with iron deficiency, these changes being more marked in iron deficient controls than in those with infection or malignancy. In iron deficient controls results of whole body counting correlate very well with other haematological investigations. (orig.) [de

  18. Oil flow rate measurements using 198Au and total count technique

    International Nuclear Information System (INIS)

    Goncalves, Eduardo R.; Crispim, Verginia R.

    2013-01-01

    In industrial plants, oil and oil compounds are usually transported by closed pipelines with circular cross-section. The use of radiotracers in oil transport and processing industrial facilities allows calibrating flowmeters, measuring mean residence time in cracking columns, locate points of obstruction or leak in underground ducts, as well as investigating flow behavior or industrial processes such as in distillation towers. Inspection techniques using radiotracers are non-destructive, simple, economic and highly accurate. Among them, Total Count, which uses a small amount of radiotracer with known activity, is acknowledged as an absolute technique for flow rate measurement. A viscous fluid transport system, composed by four PVC pipelines with 13m length (12m horizontal and 1m vertical) and 1/2, 3/4, 1 and 2-inch gauges, respectively, interconnected by maneuvering valves was designed and assembled in order to conduct the research. This system was used to simulate different flow conditions of petroleum compounds and for experimental studies of flow profile in the horizontal and upward directions. As 198 Au presents a single photopeak (411,8 keV), it was the radioisotope chosen for oil labeling, in small amounts (6 ml) or around 200 kBq activity, and it was injected in the oil transport lines. A NaI scintillation detector 2'x 2', with well-defined geometry, was used to measure total activity, determine the calibration factor F and, positioned after a homogenization distance and interconnected to a standardized electronic set of nuclear instrumentation modules (NIM), to detect the radioactive cloud. (author)

  19. A ppendicitis with Positive Ultrasound and its Relation to Total and Differential Leucocytic Count

    International Nuclear Information System (INIS)

    Saleh, G.M.; Sabek, E.A.S.; Elessiely, E.S.; Ibrahim, E.M.

    2016-01-01

    Background:The most common cause of acute surgical abdomen is acute appendicitis and the most commonly done emergency surgery is appendectomy. Although a battery of tests and different scoring methods are available for diagnosis of acute appendicitis, it is very difficult to prevent negative explorations for appendicectomy (15 - 30%). None of the tests has satisfactory Sensitivity and specificity that can be relied upon. Objectives: The aim of the present study was to evaluate the role of total and differential leukocyte count, and ultrasonography (USG) of abdomen in diagnosing acute appendicitis and reducing the rates of negative appendicectomies and to prevent complications like perforation, peritonitis, and the longer the delay between diagnosis and surgery, the more likely is the perforation leading to peritonitis. In addition, emphasis was given to whether combining the investigations for the same patient would improve the diagnostic accuracy. Materials and Methods : A total of 76 clinically diagnosed patients of acute appendicitis, posted for emergency appendicectomy were included in the study in General Surgery Department of EL-Salam Hospital. This study was conducted in the period October 2012 to September 2013. Preoperatively blood tests for, total leukocyte count, differential leukocyte count(DLC) and USG abdomen were done. All patients were subjected to histological examination postoperatively, which was taken as the gold standard. The three investigations results were correlated with histopathological examination reports to evaluate their role in diagnosis of acute appendicitis. Results: In the present study, the US has the highest sensitivity and specificity (90%, 80%) followed by Total leucocyte count (87.5%, 90%), white Neutrophil count (78.75%, 80%). Combining US and WBC count increases the sensitivity and specificity of the tests (96.25%, 80%). Conclusion: US contains important diagnostic information and hence should always be included in the

  20. An experimental test on large animals of MCNP application for whole body counting

    International Nuclear Information System (INIS)

    Borisov, N.; Yatsenko, V.; Kochetkov, O.; Gusev, I.; Vlasov, P.; Kalistratova, V.; Nisimov, P.; Levochkin, F.; Borovkov, M.; Stolyarov, V.; Tsedish, S.; Tyurin, I.; Franck, D.; Carlan, L. de

    2005-01-01

    Measurements of actinide body burden using whole body counting spectrometry is hampered due to intensive absorption of γ-rays inside the patient's body, which depends on the anatomy of a patient. To establish the correspondence between pulse-height-spectra intensity and radionuclide activity, Monte Carlo calculations are widely used. For such calculations, the radiation transport geometry is usually described in terms of small rectangular boxes (voxels) retrieved from computed tomography or magnetic resonance images. The software for Monte Carlo-assisted calibration of whole body counting, which performs automatic creation of individual MCNP voxel phantoms, was checked in a quasi-in vivo experiment on large animals. During the experiment, pigs of 35-40 kg body mass were used as phantoms for measurement of actinides body burden. 241 Am was administered (via injection of a radioactive solution or via implantation of plastic capsules containing the radioactive material) into the lungs of pigs. The pigs were measured using the pure germanium low-energy γ-spectrometers. The images of animals were obtained using the computed tomography machine. On the base of these tomograms, MCNP4c2 calculations were done to obtain the pulse-height-spectra of the whole body counters. The experimental results were reproduced in calculations with error of less than 30% for 241 Am administered via injection and less than 10% for 241 Am administered inside the capsules. (authors)

  1. Relationship of Total Motile Sperm Count and Percentage Motile Sperm to Successful Pregnancy Rates Following Intrauterine Insemination

    OpenAIRE

    Pasqualotto, Eleonora B.; Daitch, James A.; Hendin, Benjamin N.; Falcone, Tommaso; Thomas, Anthony J.; Nelson, David R.; Agarwal, Ashok

    1999-01-01

    Purpose:This study sought (i) to investigate the relationship between postwash total motile sperm count and postwash percentage motile sperm in predicting successful intrauterine insemination and (ii) to determine the minimal postwash total motile sperm count required to achieve pregnancy with intrauterine insemination.

  2. Immature germ cells in semen - correlation with total sperm count and sperm motility

    Directory of Open Access Journals (Sweden)

    Priya S Patil

    2013-01-01

    Conclusions: Round cells in semen can be differentiated into immature germ cells and leucocytes using simple staining methods. The differential counts mentioned in a semen report give valuable and clinically relevant information. In this study, we observed a negative correlation between total count and immature germ cells, as well as sperm motility and shedding of immature germ cells. The latter was statistically significant with a P value 0.000.

  3. Detection of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa)

    Science.gov (United States)

    Ekawati, ER; Yusmiati, S. N. H.

    2018-01-01

    Blood cockle (Anadara granosa) has high level of zinc and protein, which is beneficial for therapeutic function for malnourished particularly stunting case in children. Zinc in animal foods is more absorbable than that from vegetable food. Blood cockle (Anadara granosa) is rich in nutrient and an excellent environment for the growth of microorganisms. This research aimed to identify the contamination of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa). This was observation research with laboratory analysis. Salmonella sp. and Vibrio sp. were detected from blood cockle. Total plate count was determine of the total amount of the bacteria. Results detected from 20 samples of blood cockle showed that all samples were negative of Salmonella sp. and 1 sample positive Vibrio sp. The result of total plate count bacteria was < 5 x 105 colony/g sample.

  4. A method for total body irradiation

    International Nuclear Information System (INIS)

    Yasukochi, Hiroshi; Higashi, Shizuka; Okuhata, Yoshitaka; Lee, Keiichi; Ishioka, Kuniaki; Murakami, Koji; Nagai, Jun; Kuniyasu, Yoshio

    1988-01-01

    In these two years, we have treated four infant patients of acute leukemia by Cobalt-60 total body irradiation and bone marrow transplantation. During total body irradiation, thermoluminescence dosimeters were attached to the skin of patients. For four patients, nine dosimetries were performed. Reliability of this method was examined by phantom experiment. Every irradiation for the patient per fraction was 2.4 Gy, that is, 60 cGy for each four positions, right decubitus A-P and PA directions and left decubitus A-P and PA directions under aseptic circumstances. Radiation dose was uniform by this technique for each patient, and average determined dose for surface of the patients was between 87 % and 106 % compared with the air dose of the center of aseptic space (wagon). As the result, we suggest that this method is suitable for the total body irradiation of acute leukemia of infant. (author)

  5. Changes in total viable count and TVB-N content in marinated chicken breast fillets during storage

    Science.gov (United States)

    Baltić, T.; Ćirić, J.; Velebit, B.; Petronijević, R.; Lakićević, B.; Đorđević, V.; Janković, V.

    2017-09-01

    Marination is a popular technique for enhancing meat properties. Depending on the marinade type and ingredients added, marination can improve sensory, chemical and microbiological quality of meat products. In this study, the total viable count and total volatile basic nitrogen (TVB-N) content in marinated chicken breast fillets were investigated. The possible correlation between bacterial growth and formation of TVB-N was also tested. Chicken breast fillets were immersed in a solution of table salt (as a control) orthree different marinades,which consisted of table salt, sodium tripolyphosphate and/or sodium citrate, and stored in air for nine days at 4±1°C. Analyses of the total viable count and TVB-N were performed on days0, 3, 6 and 9 day of storage. The total viable count gradually increased in all examined groups, and statistically significant differences (pchicken were significantly higher (pchicken marinated with sodium citrate was established (pchicken marinated with sodium tripolyphosphate.

  6. Expected total counts for the Self-Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Rossa, Riccardo [Belgian nuclear research centre SCK.CEN (Belgium); Universite Libre de Bruxelles (Belgium); Borella, Alessandro; Van der Meer, Klaas [Belgian nuclear research centre SCK.CEN. Boeretang 200, 2400 Mol (Belgium); Labeau, Pierre-Etienne; Pauly, Nicolas [Universite Libre de Bruxelles. Av. F. D. Roosevelt 50, B1050 Brussels (Belgium)

    2015-07-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in spent fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron counts in the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach in this study consisted in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types were used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the total neutron counts that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of total neutron counts and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the total neutron counts by increasing the detector size. The study shows that the highest total neutron counts are achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the total neutron counts

  7. Feasibility study of helical tomotherapy for total body or total marrow irradiation

    International Nuclear Information System (INIS)

    Hui, Susanta K.; Kapatoes, Jeff; Fowler, Jack; Henderson, Douglas; Olivera, Gustavo; Manon, Rafael R.; Gerbi, Bruce; Mackie, T. R.; Welsh, James S.

    2005-01-01

    Total body radiation (TBI) has been used for many years as a preconditioning agent before bone marrow transplantation. Many side effects still plague its use. We investigated the planning and delivery of total body irradiation (TBI) and selective total marrow irradiation (TMI) and a reduced radiation dose to sensitive structures using image-guided helical tomotherapy. To assess the feasibility of using helical tomotherapy (A) we studied variations in pitch, field width, and modulation factor on total body and total marrow helical tomotherapy treatments. We varied these parameters to provide a uniform dose along with a treatment times similar to conventional TBI (15-30 min). (B) We also investigated limited (head, chest, and pelvis) megavoltage CT (MVCT) scanning for the dimensional pretreatment setup verification rather than total body MVCT scanning to shorten the overall treatment time per treatment fraction. (C) We placed thermoluminescent detectors (TLDs) inside a Rando phantom to measure the dose at seven anatomical sites, including the lungs. A simulated TBI treatment showed homogeneous dose coverage (±10%) to the whole body. Doses to the sensitive organs were reduced by 35%-70% of the target dose. TLD measurements on Rando showed an accurate dose delivery (±7%) to the target and critical organs. In the TMI study, the dose was delivered conformally to the bone marrow only. The TBI and TMI treatment delivery time was reduced (by 50%) by increasing the field width from 2.5 to 5.0 cm in the inferior-superior direction. A limited MVCT reduced the target localization time 60% compared to whole body MVCT. MVCT image-guided helical tomotherapy offers a novel method to deliver a precise, homogeneous radiation dose to the whole body target while reducing the dose significantly to all critical organs. A judicious selection of pitch, modulation factor, and field size is required to produce a homogeneous dose distribution along with an acceptable treatment time. In

  8. Determination of total bacterial count in raw milk by flow cytometry

    Directory of Open Access Journals (Sweden)

    Dubravka Samaržija

    2004-01-01

    Full Text Available The automatic flow cytometry as routine method for total bacterial count determination of raw ex-farm milk has recently been accepted in Croatia. This method significantly differs from the reference method (Standard Plate Count mostly in the presentation of the results obtained. Therefore, this paper summarized experiences in the application of flow cytometry in the dairy laboratories practice. The principle and the practice of the method, methodological details and factors influencing the results were described. In order to avoid problems regarding the interpretation of the results, which aregeneral problems of the quantitative microbiology, this article try to explain an appropriate conversion of the results with regards to SPC/ml, as an official method for the bacteriological quality proposal by the national legislation.

  9. Evaluation of Bacteriological Quality of Ready-to-eat Chicken Products by Total Viable Count Method

    OpenAIRE

    Ramiz Raja; Asif Iqbal; Yasir Hafiz; Mehboob Willayet; Shakoor Bhat; Mudasir Rather

    2012-01-01

    The present investigation describes the total viable count of ready-to-eat chicken products (chicken patties and chicken rolls) in Srinagar city during two seasons viz. autumn and winter. A total of 120 ready-to-eat chicken products comprising of 60 chicken patties and 60 chicken rolls were tested. The mean bacterial count of 60 chicken patties and 60 chicken rolls was 5.1281 and 4.9395 log10 cfu/g. Bacillus cereus strains were isolated from 25 of chicken patties and 22 of the chicken rolls r...

  10. The whole body counting laboratory of the Swedish Radiation Safety Authority; Straalsaekerhetsmyndighetens helkroppslaboratorium

    Energy Technology Data Exchange (ETDEWEB)

    del Risco Norrlid, Lilian; Oestergren, Inger

    2010-03-15

    One of the first whole body counting (WBC) facilities in the world sensitive enough for in vivo measurements was started by Rolf Sievert 1950 at the Radio-Physics Department at Karolinska Institute in Stockholm. During many years this was the WBC facility of the national regulatory authority and went through different modernisations along the years. During 2004-2007 the facility was rebuilt in its new location in Solna strand and the laboratory thus moved. The latter detectors, sodium iodide (NaI) scintillation detectors from the late 80's and most electronic were kept. The measurement geometry and the background conditions have changed. This report describes the new facility's characteristics and presents the results for a first round of measurements on a non-contaminated group of persons for control of Cs-137 and K-40. The background in the new facility was monitored during 2007-2009 and is stable but higher than in the former location. The cause for the higher background is related to the presence of Radon progeny in the laboratory environment due to a different ventilation system. The limits of detection are 22 Bq for Cs-137 and 300 Bq for K-40, this for a half an hour measurement of a person of 75 kg weight. Measurements were run on a control group of persons to determine the activity concentrations of Cs-137 and K-40. The control group was populated with persons who had taken part in previous control groups at the former location. The purpose was to compare the activity concentrations of K-40 at the new laboratory in Solna strand and the former laboratory at Karolinska, since it is well known that the concentration of K-40 doesn't change significantly for the same person. The comparison revealed an underestimation of K-40 for most of the cases. A correction to the activities of Cs-137 and K-40 was applied for each member of the group. The correction factor is based on the theoretical estimation of K-40, which depends on the particular length

  11. Absorption and retention studies of trace elements and minerals in rats using radiotracers and whole-body counting

    NARCIS (Netherlands)

    Berg, van den G.J.; Wolterbeek, H.Th.; de Goeij, J.J.M.; Beynen, A.C.

    1995-01-01

    A description is given of a whole-body counting technique using radiotracers, permitting the determination of true absorption and endogenous excretion of trace elements and minerals in the rat in vivo. This non-invasive counting method involves oral and intraperitoneal administration of tracer doses

  12. Therapeutic use of fractionated total body and subtotal body irradiation

    International Nuclear Information System (INIS)

    Loeffler, R.K.

    1981-01-01

    Ninety-one patients were treated using fractionated subtotal body (STBI) or total body irradiation (TBI). These patients had generalized lymphomas, Hodgkin's disease, leukemias, myelomas, seminomas, or oat-cell carcinomas. Subtotal body irradiation is delivered to the entire body, except for the skull and extremities. It was expected that a significantly higher radiation dose could be administered with STBI than with TBI. A five- to ten-fold increase in tolerance for STBI was demonstrated. Many of these patients have had long-term emissions. There is little or no treatment-induced symptomatology, and no sanctuary sites

  13. Total motile sperm count has a superior predictive value over the WHO 2010 cut-off values for the outcomes of intracytoplasmic sperm injection cycles.

    Science.gov (United States)

    Borges, E; Setti, A S; Braga, D P A F; Figueira, R C S; Iaconelli, A

    2016-09-01

    The objective of this study was to compare (i) the intracytoplasmic sperm injection outcomes among groups with different total motile sperm count ranges, (ii) the intracytoplasmic sperm injection outcomes between groups with normal and abnormal total motile sperm count, and (iii) the predictive values of WHO 2010 cut-off values and pre-wash total motile sperm count for the intracytoplasmic sperm injection outcomes, in couples with male infertility. This study included data from 518 patients undergoing their first intracytoplasmic sperm injection cycle as a result of male infertility. Couples were divided into five groups according to their total motile sperm count: Group I, total motile sperm count sperm count 1-5 × 10(6) ; group III, total motile sperm count 5-10 × 10(6) ; group IV, total motile sperm count 10-20 × 10(6) ; and group V, total motile sperm count >20 × 10(6) (which was considered a normal total motile sperm count value). Then, couples were grouped into an abnormal and normal total motile sperm count group. The groups were compared regarding intracytoplasmic sperm injection outcomes. The predictive values of WHO 2010 cut-off values and total motile sperm count for the intracytoplasmic sperm injection outcomes were also investigated. The fertilization rate was lower in total motile sperm count group I compared to total motile sperm count group V (72.5 ± 17.6 vs. 84.9 ± 14.4, p = 0.011). The normal total motile sperm count group had a higher fertilization rate (84.9 ± 14.4 vs. 81.1 ± 15.8, p = 0.016) and lower miscarriage rate (17.9% vs. 29.5%, p = 0.041) compared to the abnormal total motile sperm count group. The total motile sperm count was the only parameter that demonstrated a predictive value for the formation of high-quality embryos on D2 (OR: 1.18, p = 0.013), formation of high-quality embryos on D3 (OR: 1.12, p = 0.037), formation of blastocysts on D5 (OR: 1.16, p = 0.011), blastocyst expansion grade on D5

  14. Binomial distribution of Poisson statistics and tracks overlapping probability to estimate total tracks count with low uncertainty

    International Nuclear Information System (INIS)

    Khayat, Omid; Afarideh, Hossein; Mohammadnia, Meisam

    2015-01-01

    In the solid state nuclear track detectors of chemically etched type, nuclear tracks with center-to-center neighborhood of distance shorter than two times the radius of tracks will emerge as overlapping tracks. Track overlapping in this type of detectors causes tracks count losses and it becomes rather severe in high track densities. Therefore, tracks counting in this condition should include a correction factor for count losses of different tracks overlapping orders since a number of overlapping tracks may be counted as one track. Another aspect of the problem is the cases where imaging the whole area of the detector and counting all tracks are not possible. In these conditions a statistical generalization method is desired to be applicable in counting a segmented area of the detector and the results can be generalized to the whole surface of the detector. Also there is a challenge in counting the tracks in densely overlapped tracks because not sufficient geometrical or contextual information are available. It this paper we present a statistical counting method which gives the user a relation between the tracks overlapping probabilities on a segmented area of the detector surface and the total number of tracks. To apply the proposed method one can estimate the total number of tracks on a solid state detector of arbitrary shape and dimensions by approximating the tracks averaged area, whole detector surface area and some orders of tracks overlapping probabilities. It will be shown that this method is applicable in high and ultra high density tracks images and the count loss error can be enervated using a statistical generalization approach. - Highlights: • A correction factor for count losses of different tracks overlapping orders. • For the cases imaging the whole area of the detector is not possible. • Presenting a statistical generalization method for segmented areas. • Giving a relation between the tracks overlapping probabilities and the total tracks

  15. Fractionated total body irradiation and autologous bone marrow transplantation in dogs: Hemopoietic recovery after various marrow cell doses

    International Nuclear Information System (INIS)

    Bodenburger, U.; Kolb, H.J.; Thierfelder, S.; Netzel, B.; Schaeffer, E.; Kolb, H.

    1980-01-01

    Hemopoietic recovery was studied in dogs given 2400 R fractionated total body irradiation within one week and graded doses of cryopreserved autologous bone marrow. Complete hemopoietic recovery including histology was observed after this dose and sufficient doses of marrow cells. Doses of more than 5.5 x 10 7 mononuclear marrow cells/kg body weight were sufficient for complete recovery in all dogs, 1.5 to 5.5 x 10 7 cells/kg were effective in some of the dogs and less than 1.5 x 10 7 cells/kg were insufficient for complete recovery. Similarly, more than 30000 CFUsub(c)/kg body weight were required for hemopoietic recovery. The optimal marrow cell dose which has been defined as the minimal dose required for the earliest possible recovery of leukocyte and platelet counts was 7-8 x 10 7 mononuclear marrow cells/kg body weight. It has been concluded that fractionated total body irradiation with 2400 R dose not require greater doses of marrow cells for hemopoietic reconstitution than lower single doses and that the hemopoietic microenvironment is not persistently disturbed after this dose. (author)

  16. [Prediction of the total Japanese cedar pollen counts based on male flower-setting conditions of standard trees].

    Science.gov (United States)

    Yuta, Atsushi; Ukai, Kotaro; Sakakura, Yasuo; Tani, Hideshi; Matsuda, Fukiko; Yang, Tian-qun; Majima, Yuichi

    2002-07-01

    We made a prediction of the Japanese cedar (Cryptomeria japonica) pollen counts at Tsu city based on male flower-setting conditions of standard trees. The 69 standard trees from 23 kinds of clones, planted at Mie Prefecture Science and Technology Promotion Center (Hakusan, Mie) in 1964, were selected. Male flower-setting conditions for 276 faces (69 trees x 4 points of the compass) were scored from 0 to 3. The average of scores and total pollen counts from 1988 to 2000 was analyzed. As the results, the average scores from standard trees and total pollen counts except two mass pollen-scattered years in 1995 and 2000 had a positive correlation (r = 0.914) by linear function. On the mass pollen-scattered years, pollen counts were influenced from the previous year. Therefore, the score of the present year minus that of the previous year were used for analysis. The average scores from male flower-setting conditions and pollen counts had a strong positive correlation (r = 0.994) when positive scores by taking account of the previous year were analyzed. We conclude that prediction of pollen counts are possible based on the male flower-setting conditions of standard trees.

  17. Nutritional status, quality of life and CD4 cell count of adults living ...

    African Journals Online (AJOL)

    Keywords: CD4 cell count; Quality of Life; adults; nutritional status; nutritional intake. Nutritional status .... used to calculate the Body Mass Index (BMI). BMI was ... fat consumption as a percentage of the total food energy intake, and component ..... except when the CD4 counts fall very low.5,27 The CD4 cell count may offer a ...

  18. Quality of raw cow milk in Republic of Macedonia determined through the testing of somatic cell count and total viable count

    Directory of Open Access Journals (Sweden)

    Angelovski Ljupco

    2008-11-01

    Full Text Available Somatic cells count and total viable count are criteria used to estimate the compliance of raw cow milk with the Book of rules for demands for safety and hygiene and procedures for official controls of milk and milk products, Official Gazette of RM 157/2007. According to the given demands, raw milk operators are obliged to conduct all procedures and to guarantee that milk is in compliance with the criteria laid down in Book of rules. At the same time, Republic of Macedonia have to fulfill EU criteria laid down in Directive 92/46 (Council directive 92/46/EEC laying down the health rules for the production and placing on the market of raw milk, heat-treated milk and milkbased products for quality of raw milk as part of implementation of community legislation and milk production. The independent laboratory for milk quality control at FVM-Skopje, in frame of its activities in the period February- August 2008 has conducted a study for obtaining preliminary results for the situation with raw milk quality produced in R. of Macedonia for somatic cells counts and total viable count. In the study we analyzed 2065 samples for TVC and 1625 samples for SCC of raw milk samples produced in different parts of the country. From the tested samples only 41,8% fulfill criteria for SCC and 41,45% criteria for TVC lay down in Book of rules for 2008. Assessment of the results in light of Council Directive it is obvious that only 42,7% of the samples for SCC and 10,7% for TVC fulfill the criteria of Council Directive having in mind different requirements vs. Book of rules.

  19. Quantitative estimation of 123I-MIBG scintigraphy in neuroblastoma. Usefulness of the total body retention rate

    International Nuclear Information System (INIS)

    Okuyama, Chio; Ushijima, Yo; Sugihara, Hiroki; Nishimura, Tunehiko

    2000-01-01

    A new method of easily and simply quantifying 123 I-MIBG accumulation as a criterion for curative effect of chemotherapy in infants with neuroblastoma was developed. This method uses the data from two images: an early image (at 5-7.5 hr) and a delayed image (at 25-32 hr). Twenty infants with untreated neuroblastoma which showed clear accumulation of 123 I-MIBG at the primary site were examined. The differences between the accumulation counts on the early image and the delayed image showed that washout of 123 I-MIBG in the neuroblastomas was delayed in tumor regions. This finding indicated that the total body 123 I-MIBG retention rate reflects the total volume of the neuroblastoma. The 123 I-MIBG retention rate was significantly higher in patients with advanced stage neuroblastoma with systemic metastases, and there was a good correlation between the retention rate and tumor markers (VMA and HVA values in urine). The response to chemotherapy paralleled the change in markers. These results suggested that the total body 123 I-MIBG retention rate is useful as a criterion for curative effect in advanced neuroblastoma. (K.H.)

  20. Normal iron absorption determined by means of whole body counting and red cell incorporation of 59Fe

    International Nuclear Information System (INIS)

    Larsen, L.; Milman, N.

    1977-01-01

    Gastrointestinal iron absorption was measured in 27 normal subjects (19 females and 8 males) by means of whole body counting. Whole body retention 14 days after oral administration of 10μCi 59 Fe together with a carrier dose of 9.9 mg Fe 2+ (as sulphate), was used as an expression of absorption. The percentage incorporation in the total erythrocyte mass of administered 59 Fe (erythrocyte incorporation) and of absorbed 59 Fe (red cell utilization) was also estimated. Geometric mean iron absorption was 8.3+-2.1 (SD% in females, 9.1+-2.2 % in males and 8.5+-2.1 % in the entire series. The difference between males and females was not significant. Erythrocyte incorporation was 7.7+-2.2 (SD) % (geometric mean) in the entire series and the correlation between iron absorption and erythrocyte incorporation was highly significant (r = 0.96,P < 0.001). Red cell utilization averaged 92.9 +- 4.0 (SEM)% (arithmetic mean) in the entire series. (author)

  1. Effects of Wine by-Products on Growth Performance, Complete Blood Count and Total Antioxidant Status in Broilers

    Directory of Open Access Journals (Sweden)

    SM Pascariu

    Full Text Available ABSTRACT This study aimed to investigate the effect of whole grape pomace (GP, grape seed (GS and grape pomace polyphenolic extract (GPEP on growth performance, total antioxidant status (TAS and complete blood count (CBC of 40-day-old chicks (hybrid Cobb 500. A total of 432 unsexed one-day-old chicks were divided into six groups: control (CON and five experimental groups, 10 g/kg GP, 20 g/kg GP, 5 g/kg GS, 10 g/kg GS and 15 mL/L GPEP. The results showed a higher increase in growing rate in 5 g/kg GS group, from the first week of the chicks’ life throughout their growth, the average body weight of the chicks being significantly higher (p0.05 at 40 days of age. As a conclusion, the amount of 5 g/kg seeds, 10 g/kg and 20 g/kg pomace, can be added to the diet of the broilers, the dose of 5 g/kg seeds in the diet offering advantages in growing rate and feed valorization in weight gain.

  2. The biological effects of high dose total body irradiation in beagle dogs

    International Nuclear Information System (INIS)

    Luo Qingliang; Liu Xiaolan; Hao Jing; Xiong Guolin; Dong Bo; Zhao Zhenhu; Xia Zhengbiao; Qiu Liling; Mao Bingzhi

    2002-01-01

    Objective: To evaluate the biological effects of Beagle dogs irradiated by γ-rays at different doses. Methods: All Beagle dogs were divided into six groups and were subjected respectively to total-body irradiation (TBI) with a single dose of 6.5, 5.5, 5.0, 4.5, 3, 5 and 2.5 Gy γ-rays delivered by 60 Co sources at 7.224 x 10 -2 C/kg per minute. The general condition, blood cell counts and bone marrow cell CFC assays were observed. Results: Vomiting occurred at 0.5 to 2 hours after TBI in all groups. In 6.5 Gy group 3/5 dogs had blood-watery stool and 1/5 in 5.5 Gy group had watery stool. Diarrhea occurred in all other animals. Only one dog in 2.5 Gy group survived, all of others died. in order of decreasing irradiation dosage, the average survival time was 5.0, 8.0, 9.3, 9.5, 10.5 and 14.1 days, respectively. Conclusions: According to the clinical symptoms, leukocyte count and survival time of the dogs, the irradiation dose which will induce very severe hematopoietic radiation syndrome in Beagle dogs is 4.5 to 5.0 Gy

  3. Early surfactant guided by lamellar body counts on gastric aspirate in very preterm infants

    DEFF Research Database (Denmark)

    Verder, Henrik Axel; Ebbesen, Finn Oluf; Fenger-Grøn, Jesper

    2013-01-01

    We have developed a rapid method, based on lamellar body counts (LBC) on gastric aspirate, for identifying newborns who will develop respiratory distress syndrome with a need for surfactant supplementation. Objective: We set out to test whether it was possible to improve the outcome when used in ...

  4. Facilities for the examination of radioactive bodies

    International Nuclear Information System (INIS)

    Ginniff, M.E.; Richardson, E.K.

    1981-01-01

    A facility for the examination of radioactive bodies comprises carriages, each transporting one or more radioactive bodies, e.g. nuclear fuel elements, which travel along a shielded passage to bring the bodies to examination stations spaced along the passage. The passage comprises a circular section tube surrounded by a thick cylinder of shielding material e.g. lead. The transverse sectional dimensions of the passage are not much larger than the corresponding dimensions of the carriages in order to maintain the radioactive region as small as possible. Equipment for the examination of the radioactive bodies is located outside the shielded passage, and may be for metallurgical examination, e.g. by ultrasonics, radiography or other non-destructive testing means, or for mensuration to identify changes in shape, dimensions or weight. (author)

  5. In-vivo determination of total body water and lean body mass in subjects by deuterium dilution

    International Nuclear Information System (INIS)

    Blagojevic, N.; Allen, B.J.; Baur, L.; Gaskin, K.

    1988-01-01

    Total body water (TBW) estimation is one of a number of basic techniques required for the determination of body composition in normal and malnourished subjects. When combined with total body nitrogen (TBN) analysis by prompt gamma neutron activation, an accurate compartmental model of in vivo body composition can be formed, providing valuable nutritional and other data. This study examines the role of TBW on its own in evaluating lean body mass. Total body water was studied in six male and five female subjects using deuterium oxide and a Fourier transform infrared spectrometer. The lean body mass calculated from the results was compared with the lean body mass deduced from established total body nitrogen measurements. A four-compartment model was also used to calculate lean body mass. Excellent agreement was shown between lean body mass derived from TBW, the four-compartment model and TBN. Hence, TBW can provide a fast, cost-efficient method for evaluating normal subjects. However, for disease-induced malnutrition, or highly developed athletes, both TBN and TBW measurements are essential to establish an accurate picture of their body composition. TBW measurements alone can monitor the hydration state of patients and as such have a useful diagnostic value

  6. In-vivo determination of total body water and lean body mass in subjects by deuterium dilution

    Energy Technology Data Exchange (ETDEWEB)

    Blagojevic, N; Allen, B J; Baur, L; Gaskin, K

    1988-12-01

    Total body water (TBW) estimation is one of a number of basic techniques required for the determination of body composition in normal and malnourished subjects. When combined with total body nitrogen (TBN) analysis by prompt gamma neutron activation, an accurate compartmental model of in vivo body composition can be formed, providing valuable nutritional and other data. This study examines the role of TBW on its own in evaluating lean body mass. Total body water was studied in six male and five female subjects using deuterium oxide and a Fourier transform infrared spectrometer. The lean body mass calculated from the results was compared with the lean body mass deduced from established total body nitrogen measurements. A four-compartment model was also used to calculate lean body mass. Excellent agreement was shown between lean body mass derived from TBW, the four-compartment model and TBN. Hence, TBW can provide a fast, cost-efficient method for evaluating normal subjects. However, for disease-induced malnutrition, or highly developed athletes, both TBN and TBW measurements are essential to establish an accurate picture of their body composition. TBW measurements alone can monitor the hydration state of patients and as such have a useful diagnostic value.

  7. Determination of iron absorption and excretion by whole-body counting

    International Nuclear Information System (INIS)

    Hollard, D.; Benabid, Y.; Berard, M.; Bonnin, J.; Darnault, J.; Millet, M.

    1969-01-01

    Using a whole-body counter, the authors have studied 59 Fe absorption and loss in 8 normal subjects and in 30 iron deficient patients. Results showed that whole-body counting provided an excellent and simple method for iron retention measurements, obviating many inaccuracies of previous technic. Normal absorption of radio iron with this procedure has ranged from 9 per cent to 20 per cent of the administered tracer in normal subjects, with a mean of 15 per cent. A significant increase in 59 Fe absorption was noted in 21 iron-deficient patients in whom the retention ranged from 40 to 100 per cent. However, 3 iron-deficient patients were found to have low absorption, and their severe iron deficiency could be correlated with this defect in absorption. This method permits also the determination of the rate of iron excretion during the following months and therefore the study of the mechanism of some pathological loss. (authors) [fr

  8. Fiber-coupled Al_2O_3:C radioluminescence dosimetry for total body irradiations

    International Nuclear Information System (INIS)

    Buranurak, S.; Andersen, C.E.

    2016-01-01

    In vivo dosimetry can be important and relevant in radiotherapy, especially when commissioning new treatment techniques at hospitals. This study investigates the potential use of fiber-coupled radioluminescence (RL) dosimetry based on Al_2O_3:C or organic plastic scintillators for this purpose in the context of Total Body Irradiations (TBIs) where patients are treated with large fields of 6 or 18 MV photons at an extended source-to-surface distance (SSD). The study shows that Al_2O_3:C dosimetry using the saturated-RL protocol may be suitable for real-time in vivo dosimetry during TBI treatments from the perspective of the good agreement with alanine dosimetry and other critical phantom tests, including the ability to cope with the large stem signal experienced during TBI treatments at extended SSD. In contrast, the chromatic stem removal technique often used for organic plastic scintillators did not work well in large fields with the tested calibration procedure and instrumentation. An apparent dose-rate effect discussed in a previous study of the RL properties of Al_2O_3:C (Andersen et al., 2011) was found to have resulted from an overlooked dead time problem in the counting system, and this potential caveat can therefore be removed from the list of potential problems associated with fiber-coupled Al_2O_3:C dosimetry using the saturated-RL protocol. This further has implications for TBI dosimetry using the RL Al_2O_3:C system due to large dose-rate differences between calibrations at the iso-center and in vivo measurements at extended source-to-surface distances. - Highlights: • Fiber-coupled dosimetry can be used for measurements during total body irradiations. • An apparent dose-effect associated with radioluminescence from Al2O3:C was resolved. • The gated-counting stem removal procedure worked well for Al2O3:C in pulsed accelerator beams. • The chromatic stem removal procedure did not work well with the tested instrumentation and organic plastic

  9. Acute tolerance of hyperfractionated accelerated total body irradiation

    International Nuclear Information System (INIS)

    Latz, D.; Schraube, P.; Wannenmacher, M.

    1996-01-01

    Background: Acute side effects of total body irradiation lead to intense molestations of the patients. Therefore, it is desirable to take measures to reduce these side effects. In a retrospective study the frequency on acute side effects of a hyperfractionated accelerated total body irradiation was assessed and compared to frequencies of other exposure schedules published in the literature. Additionally the influence of ondansetron on the frequency of nausea and vormiting was investigated. Patients and Method: From 1989 to 1992, 76 patients (47 male, 29 female; median age 38 years) underwent total body irradiation before autologeous bone marrow transplantation. They received 3 daily doses of 1.20 Gy each every 4 h on 4 successive days to a total dose of 14,40 Gy. Thirty-nine patients received 3x8 mg (daily, intravenous or per os) ondansetron during the whole course of irradiation. Results: The most relevant side effects were nausea and vomiting. Patients, who did not receive ondansetron (n=37) showed a nausea and emesis rate of 73%. With ondansetron (n=39) nausea and emesis were reduced to 38%. Also the grade of severity of these side effects was reduced. Conclusions: Ondansetron proved to be an effective medicament for relieving nausea and vormiting during total body irradiation. The results obtained are in concordance with those published in the literature. (orig.) [de

  10. The effect of dietary garlic supplementation on body weight gain, feed intake, feed conversion efficiency, faecal score, faecal coliform count and feeding cost in crossbred dairy calves.

    Science.gov (United States)

    Ghosh, Sudipta; Mehla, Ram K; Sirohi, S K; Roy, Biswajit

    2010-06-01

    Thirty-six crossbred calves (Holstein cross) of 5 days of age were used to study the effect of garlic extract feeding on their performance up to the age of 2 months (pre-ruminant stage). They were randomly allotted into treatment and control groups (18 numbers in each group). Performance was evaluated by measuring average body weight (BW) gain, feed intake (dry matter (DM), total digestible nutrient (TDN) and crude protein (CP)), feed conversion efficiency (FCE; DM, TDN and CP), faecal score, faecal coliform count and feeding cost. Diets were the same for the both groups. In addition, treatment group received garlic extract supplementation at 250 mg/kg BW per day per calf. Body weight measured weekly, feed intake measured twice daily, proximate analysis of feeds and fodders analysed weekly, faecal scores monitored daily and faecal coliform count done weekly. There was significant increase in average body weight gain, feed intake and FCE and significant decrease in severity of scours as measured by faecal score and faecal coliform count in the treatment group compared to the control group (P Feed cost per kilogramme BW gain was significantly lower in the treatment group compared to control group (P calves for better performance.

  11. A gamma camera count rate saturation correction method for whole-body planar imaging

    Science.gov (United States)

    Hobbs, Robert F.; Baechler, Sébastien; Senthamizhchelvan, Srinivasan; Prideaux, Andrew R.; Esaias, Caroline E.; Reinhardt, Melvin; Frey, Eric C.; Loeb, David M.; Sgouros, George

    2010-02-01

    Whole-body (WB) planar imaging has long been one of the staple methods of dosimetry, and its quantification has been formalized by the MIRD Committee in pamphlet no 16. One of the issues not specifically addressed in the formalism occurs when the count rates reaching the detector are sufficiently high to result in camera count saturation. Camera dead-time effects have been extensively studied, but all of the developed correction methods assume static acquisitions. However, during WB planar (sweep) imaging, a variable amount of imaged activity exists in the detector's field of view as a function of time and therefore the camera saturation is time dependent. A new time-dependent algorithm was developed to correct for dead-time effects during WB planar acquisitions that accounts for relative motion between detector heads and imaged object. Static camera dead-time parameters were acquired by imaging decaying activity in a phantom and obtaining a saturation curve. Using these parameters, an iterative algorithm akin to Newton's method was developed, which takes into account the variable count rate seen by the detector as a function of time. The algorithm was tested on simulated data as well as on a whole-body scan of high activity Samarium-153 in an ellipsoid phantom. A complete set of parameters from unsaturated phantom data necessary for count rate to activity conversion was also obtained, including build-up and attenuation coefficients, in order to convert corrected count rate values to activity. The algorithm proved successful in accounting for motion- and time-dependent saturation effects in both the simulated and measured data and converged to any desired degree of precision. The clearance half-life calculated from the ellipsoid phantom data was calculated to be 45.1 h after dead-time correction and 51.4 h with no correction; the physical decay half-life of Samarium-153 is 46.3 h. Accurate WB planar dosimetry of high activities relies on successfully compensating

  12. Total body and regional bone mineral content in hemodialysis patients

    International Nuclear Information System (INIS)

    Hagiwara, Satoshi; Aratani, Hideyui; Miki, Takami; Nishizawa, Yoshiki; Okamura, Terue; Koizumi, Yoshiko; Ochi, Hironobu; Morii, Hirotoshi

    1994-01-01

    Bone mineral content (BMC) in the total body and lumbar spine was evaluated in 126 hemodialysis patients (60 males, 66 females) by dual photon absorptiometry with the Norland DBD 2600. Measurements of: 1) total body BMC divided by lean body mass (BMC TB /LBM), 2) bone mineral density (BMD) of total body, 3) BMD of four regional sections (head, trunk, pelvis, and legs), and 4) BMD of lumbar spine, generally showed a significant decrease in the hemodialysis patients compared to the reference population. However, arm BMD did not show a significant difference between patients and control populations. The z-score of BMC TB /LBM declined significantly throughout the duration of hemodialysis, although that of the lumbar spine BMD did not. It should be noted that the degree of decrease in BMC was more prominent in the total body measurement than in the lumbar spine measurement. There was preferential osteopenia of the total body in the hemodialysis patients. Although the lumbar spine BMD showed a lower value than the control population, the lumbar spine is not the recommended region to monitor the BMD change in hemodialysis patients. (author)

  13. Changes in body chemical composition with age measured by total-body neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Vaswani, A.; Zanzi, I.; Aloia, J.F.; Roginsky, M.S.; Ellis, K.J.

    1976-01-01

    Total-body levels of calcium and phosphorus (reflecting skeletal mass) and total-body levels of potassium (reflecting muscle mass) were measured by neutron activation analysis in 39 men and 40 women ages 30 to 90 yr. In order to intercompare the total body calcium (TBCa) values in a heterogeneous population, such as this, it was necessary to normalize the data for skeletal size. The normalization consisted of dividing the absolute calcium level by the predicted calcium level for each individual matched to a set of critical parameters. The parameter used in the computation of normal values were age, sex, muscle mass, i.e., total body potassium (TBK) and height. For the calcium data of the women, it was necessary to add an age correction factor after the age of 55 yr. The calcium ratio (mean ratio of the predicted to measured TBCa) in men was 1.000 +- 7.8 percent and in women 0.996 +- 7.1 percent. The TBCa of normal males and females can thus be predicted to +-13 percent (at the 90 percent confidence level). An exception to this was found in males (70 to 90 yr) who exhibited a mean calcium ratio greater than 1.13

  14. Regulatory inspection of nuclear facilities and enforcement by the regulatory body. Safety guide

    International Nuclear Information System (INIS)

    2002-01-01

    The purpose of this Safety Guide is to provide recommendations for regulatory bodies on the inspection of nuclear facilities, regulatory enforcement and related matters. The objective is to provide the regulatory body with a high level of confidence that operators have the processes in place to ensure compliance and that they do comply with legal requirements, including meeting the safety objectives and requirements of the regulatory body. However, in the event of non-compliance, the regulatory body should take appropriate enforcement action. This Safety Guide covers regulatory inspection and enforcement in relation to nuclear facilities such as: enrichment and fuel manufacturing plants; nuclear power plants; other reactors such as research reactors and critical assemblies; spent fuel reprocessing plants; and facilities for radioactive waste management, such as treatment, storage and disposal facilities. This Safety Guide also covers issues relating to the decommissioning of nuclear facilities, the closure of waste disposal facilities and site rehabilitation. Section 2 sets out the objectives of regulatory inspection and enforcement. Section 3 covers the management of regulatory inspections. Section 4 covers the performance of regulatory inspections, including internal guidance, planning and preparation, methods of inspection and reports of inspections. Section 5 deals with regulatory enforcement actions. Section 6 covers the assessment of regulatory inspections and enforcement activities. The Appendix provides further details on inspection areas for nuclear facilities

  15. Relationship between the 137Cs whole-body counting results and soil and food contamination in farms near Chernobyl

    International Nuclear Information System (INIS)

    Takatsuji, Toshihiro; Sato, Hitoshi; Takada, Jun

    2000-01-01

    The authors measured the radioactivity in the soil and child food samples from farms near Mogilev (56--270 GBq km -2 137 Cs), Gomel (36--810 GBq km -2 137 Cs), and Klincy (59--270 GBq km -2 137 Cs), who had whole-body 137 Cs counting results measured as part of a health examination in the Chernobyl Sasakawa Health and Medical Cooperation Project. Soil contamination on the family farm seems to be the main source of human contamination because most of the people in the area live on small farms and they and their domestic animals eat crops from the farms. A clear correlation was found between the children's whole-body 137 Cs counting results and the radioactivity in their food (correlation coefficient: 0.76; confidence level of correlation: 3.2 x 10 -9 ). There were also significant correlations between the whole-body 137 Cs counting results and both the radioactivity of the soil samples (correlation coefficient: 0.22; confidence level of correlation: 0.0107) and the average contamination level of their current residence (correlation coefficient: 0.20; confidence level of correlation: 0.0174)

  16. Reference values for maternal total and differential leukocyte counts in different trimesters of pregnancy and the initial postpartum period in western Turkey.

    Science.gov (United States)

    Sanci, Muzaffer; Töz, Emrah; Ince, Onur; Özcan, Aykut; Polater, Kevser; Inan, Abdurrahman Hamdi; Beyan, Emrah; Akkaya, Emrah

    2017-07-01

    The aim of this study was to investigate alterations in the leukocyte and differential leukocyte counts in different trimesters of pregnancy and the initial postpartum period. The study population consisted of 40,325 pregnant women. A full blood count and automated differential leukocyte count were performed and all the haemogram results in the different trimesters of pregnancy were recorded. Percentiles were calculated using statistical software. A total of 82,786 complete blood count evaluations were performed in 40,325 subjects from the 6th to 41st week of pregnancy and in the initial postpartum period. The leukocyte counts increased from the 1st to the 3rd trimester and peaked in the initial postpartum period. Our reference values for the total and differential leukocyte counts may assist clinicians in distinguishing between leukocytosis and pathological elevation of the white blood cell count during pregnancy and the initial postpartum period. Impact statement Pregnancy requires profound adaptation by multiple systems to accommodate the demands of the developing foetus. Similar to all other systems, many haematological changes occur during pregnancy. Studies of normal variation in leukocyte counts were insufficient to distinguish normal from abnormal leukocyte counts during pregnancy and in the initial postpartum period, due to small numbers of patients and a lack of differential leukocyte counts. Without reference leukocyte levels, infections may be more difficult to assess during pregnancy and in the postpartum period. In this study, we report the 3rd, 5th, 10th, 50th, 95th and 99th percentile values for the total and differential leukocyte counts according to trimester in normal pregnancy and the initial postpartum period. Our reference values for the total and differential leukocyte counts in each trimester and the initial postpartum period may assist clinicians in distinguishing between normal leukocytosis and pathological elevation of the white blood

  17. Quality control of dosimetry in total body irradiation

    International Nuclear Information System (INIS)

    Kallinger, W.

    1986-11-01

    An on-line dose measurement system for the quality control of the treatment of leukemia by means of total body irradiation with Co-60 gamma radiation is introduced. An ionization chamber and 5 diodes arranged on the surface of the patient incorporated with a microprocessor provides useful information and data necessary for the treatment. Following the concerted treatment procedure employing this system, the treatment of leukemia by means of total body irradiation is expected to be improved

  18. Myeloproliferative disorders in patients with rheumatoid arthritis treated with total body irradiation

    International Nuclear Information System (INIS)

    Urowitz, M.B.; Rider, W.D.

    1985-01-01

    Four patients with refractory rheumatoid arthritis were treated with total body irradiation administered in two sittings, 300 to 400 rads to each half of the body. All four patients had taken antimetabolites prior to receiving total body irradiation, and two continued to use them after total body irradiation. Two patients had taken alkylating agents before, and one had used them after total body irradiation. All patients showed clinical improvement. However, in two patients myeloproliferative disorders developed: a myelodysplastic preleukemia at 40 months after total body irradiation in one and acute myelogenous leukemia at 25 months in the other. Total body irradiation differs from total nodal irradiation in the total dose of irradiation (300 to 400 rads versus 2,000 to 3,000), and in the duration of the therapy (two sittings versus treatment over several weeks to months). Furthermore, the patients in the total body irradiation study frequently used cytotoxic drugs before and/or after irradiation, whereas in one total nodal irradiation study, azathioprine (2 mg/kg per day or less) was permitted, but no other cytotoxic agents were allowed. Rheumatologists may therefore face a binding decision when deciding to treat a patient with rheumatoid arthritis with either a cytotoxic drug or irradiation

  19. Total body irradiation with a reconditioned cobalt teletherapy unit.

    Science.gov (United States)

    Evans, Michael D C; Larouche, Renée-Xavière; Olivares, Marina; Léger, Pierre; Larkin, Joe; Freeman, Carolyn R; Podgorsak, Ervin B

    2006-01-01

    While the current trend in radiotherapy is to replace cobalt teletherapy units with more versatile and technologically advanced linear accelerators, there remain some useful applications for older cobalt units. The expansion of our radiotherapy department involved the decommissioning of an isocentric cobalt teletherapy unit and the replacement of a column-mounted 4-MV LINAC that has been used for total body irradiation (TBI). To continue offering TBI treatments, we converted the decommissioned cobalt unit into a dedicated fixed-field total body irradiator and installed it in an existing medium-energy LINAC bunker. This article describes the logistical and dosimetric aspects of bringing a reconditioned cobalt teletherapy unit into clinical service as a total body irradiator.

  20. Oak Ridge National Laboratory whole-body counter: internal operating procedure manual

    International Nuclear Information System (INIS)

    Berger, C.D.; Lane, B.H.

    1982-08-01

    The general purpose of the ORNL Whole Body Counter is to provide a rapid estimation of the type and quantity of radionuclide deposited in the human body. This report contains a review of the equipment in use at the facility and the procedure for its operation, the standard procedure for performing a routine whole body count, and a discussion of interpretation of results

  1. Experimental device for obtaining calibration factor for the total count technique

    International Nuclear Information System (INIS)

    Gonçalves, Eduardo R.; Braz, Delson; Brandão, Luís Eduardo B.

    2017-01-01

    Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 ″PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1″ x 1 ″ and a data acquisition system. (author)

  2. Experimental device for obtaining calibration factor for the total count technique

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, Eduardo R.; Braz, Delson [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Brandão, Luís Eduardo B. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Divisao de Reatores

    2017-07-01

    Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 ″PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1″ x 1 ″ and a data acquisition system. (author)

  3. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    Science.gov (United States)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  4. Some hematological parameters and the prognostic values of CD4, CD8 and total lymphocyte counts and CD4/CD8 cell count ratio in healthy HIV sero-negative, healthy HIV sero-positive and AIDS subjects in Port Harcourt, Nigeria

    Directory of Open Access Journals (Sweden)

    Blessing Didia

    2008-12-01

    Full Text Available OBJECTIVE: The present study attempts to determine normal values of CD4, CD8, CD4/CD8 ratio, total WBC and differential counts, hematocrit and total lymphocyte count (TLC in healthy HIV sero-negative and sero-positive subjects, and to assess the prognostic significance of these parameters in these subjects as compared to AIDS subjects.METHODS: A total of 300 subjects (147 M, 153 F aged between 17 and 71 years were recruited into the study. Subjects were separated according to sex and divided into three groups: Group A: healthy HIV sero-negative subjects; Group B: healthy HIV sero-positive newly diagnosed ART-naïve subjects; and Group C: AIDS subjects. CD4 and CD8 counts were determined by flow cytometry; hematocrit was determined using Hawksley micro-capillary tubes; total WBC and differential counts were determined manually with the improved Neubauer counting chamber; and TLC was obtained by multiplying the percentage of lymphocytes by the total WBC count.RESULTS: For male subjects, significant differences were found in CD4 count, CD4/CD8 count ratio, hematocrit, total WBC and TLC, whereas for female subjects, significant differences were found only in CD4 and CD4/CD8 count ratio in the three groups of subjects. In both sexes, however, these parameters were found to be highest in healthy HIV sero-negative subjects and lowest in AIDS subjects, with HIV sero-positive subjects having intermediate values. CONCLUSION: The results confirm previous reports that the CD4 count and CD4/CD8 count ratio are fairly reliable indicators of the progression of HIV infection. In addition, the results also apparently suggest that the prognostic value of CD8 count is limited and that of TLC possibly sex-dependent. The results could be of importance in our environment since previous reports have been relatively scarce.

  5. In vivo neutron activation facility at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ma, R.; Yasumura, Seiichi; Dilmanian, F.A.

    1997-11-01

    Seven important body elements, C, N, Ca, P, K, Na, and Cl, can be measured with great precision and accuracy in the in vivo neutron activation facilities at Brookhaven National Laboratory. The facilities include the delayed-gamma neutron activation, the prompt-gamma neutron activation, and the inelastic neutron scattering systems. In conjunction with measurements of total body water by the tritiated-water dilution method several body compartments can be defined from the contents of these elements, also with high precision. In particular, body fat mass is derived from total body carbon together with total body calcium and nitrogen; body protein mass is derived from total body nitrogen; extracellular fluid volume is derived from total body sodium and chlorine; lean body mass and body cell mass are derived from total body potassium; and, skeletal mass is derived from total body calcium. Thus, we suggest that neutron activation analysis may be valuable for calibrating some of the instruments routinely used in clinical studies of body composition. The instruments that would benefit from absolute calibration against neutron activation analysis are bioelectric impedance analysis, infrared interactance, transmission ultrasound, and dual energy x-ray/photon absorptiometry.

  6. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: syalcin@kastamonu.edu.tr; Gurler, O. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH (United Kingdom); NCCPM, Medical Physics, Royal Surrey County Hospital, Guildford, GU2 7XX (United Kingdom); Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey)

    2009-01-15

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies.

  7. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Gundogdu, O.; Kaynak, G.

    2009-01-01

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies

  8. Normal levels of total body sodium and chlorine by neutron activation analysis

    International Nuclear Information System (INIS)

    Kennedy, N.S.J.; Eastell, R.; Smith, M.A.; Tothill, P.

    1983-01-01

    In vivo neutron activation analysis was used to measure total body sodium and chlorine in 18 male and 18 female normal adults. Corrections for body size were developed. Normalisation factors were derived which enable the prediction of the normal levels of sodium and chlorine in a subject. The coefficient of variation of normalised sodium was 5.9% in men and 6.9% in women, and of normalised chlorine 9.3% in men and 5.5% in women. In the range examined (40-70 years) no significant age dependence was observed for either element. Total body sodium was correlated with total body chlorine and total body calcium. Sodium excess, defined as the amount of body sodium in excess of that associated with chlorine, also correlated well with total body calcium. In females there was a mean annual loss of sodium excess of 1.2% after the menopause, similar to the loss of calcium. (author)

  9. Monte Carlo simulation of lung counting efficiency using a whole-body counter at a nuclear power plant

    International Nuclear Information System (INIS)

    Dongming, L.; Shuhai, J.; Houwen, L.

    2016-01-01

    In order to routinely evaluate workers' internal exposure due to intake of radionuclides, a whole-body counter (WBC) at the Third Qinshan Nuclear Power Co. Ltd. (TQNPC) is used. Counting would typically occur immediately after a confirmed or suspected inhalation exposure. The counting geometry would differ as a result of the height of the individual being counted, which would result in over- or underestimated intake(s). In this study, Monte Carlo simulation was applied to evaluate the counting efficiency when performing a lung count using the WBC at the TQNPC. In order to validate the simulated efficiencies for lung counting, the WBC was benchmarked for various lung positions using a 137 Cs source. The results show that the simulated efficiencies are fairly consistent with the measured ones for 137 Cs, with a relative error of 0.289%. For a lung organ simulation, the discrepancy between the calibration phantom and the Chinese reference adult person (170 cm) was within 6% for peak energies ranging from 59.5 keV to 2000 keV. The relative errors vary from 4.63% to 8.41% depending on the person's height and photon energy. Therefore, the simulation technique is effective and practical for lung counting, which is difficult to calibrate using a physical phantom. (authors)

  10. Nondestructive detection of total viable count changes of chilled pork in high oxygen storage condition based on hyperspectral technology

    Science.gov (United States)

    Zheng, Xiaochun; Peng, Yankun; Li, Yongyu; Chao, Kuanglin; Qin, Jianwei

    2017-05-01

    The plate count method is commonly used to detect the total viable count (TVC) of bacteria in pork, which is timeconsuming and destructive. It has also been used to study the changes of the TVC in pork under different storage conditions. In recent years, many scholars have explored the non-destructive methods on detecting TVC by using visible near infrared (VIS/NIR) technology and hyperspectral technology. The TVC in chilled pork was monitored under high oxygen condition in this study by using hyperspectral technology in order to evaluate the changes of total bacterial count during storage, and then evaluate advantages and disadvantages of the storage condition. The VIS/NIR hyperspectral images of samples stored in high oxygen condition was acquired by a hyperspectral system in range of 400 1100nm. The actual reference value of total bacteria was measured by standard plate count method, and the results were obtained in 48 hours. The reflection spectra of the samples are extracted and used for the establishment of prediction model for TVC. The spectral preprocessing methods of standard normal variate transformation (SNV), multiple scatter correction (MSC) and derivation was conducted to the original reflectance spectra of samples. Partial least squares regression (PLSR) of TVC was performed and optimized to be the prediction model. The results show that the near infrared hyperspectral technology based on 400-1100nm combined with PLSR model can describe the growth pattern of the total bacteria count of the chilled pork under the condition of high oxygen very vividly and rapidly. The results obtained in this study demonstrate that the nondestructive method of TVC based on NIR hyperspectral has great potential in monitoring of edible safety in processing and storage of meat.

  11. Behavioural consequences of an 8 Gy total body irradiation in mice: Regulation by interleukin-4

    International Nuclear Information System (INIS)

    Van der Meeren, A.; Lebaron-Jacobs, L.

    2001-01-01

    The effects of an 8 Gy γ total body irradiation (TBI) on exploration and locomotion activities as well as temperature were studied in C57BL6/J mice. Survival, body weight, and blood cell counts were also assessed in irradiated mice treated with placebo or interleukin (IL)-4. The efficacy of IL-4 treatment on improvement in exploration activity was evaluated. The study was carried out from 3 h to 30 days following exposure. Our results showed a biphasic response to irradiation concerning the exploration activity of mice. Irradiated mice had reduced activity as early as 3 h after exposure, with recovery of activity within 24 h. The exploration activity again decreased 4 days after irradiation and the recovery occurred slowly after day 17. IL-4 ameliorated the exploration status in mice in both phases. The locomotion activity was studied using a telemetry apparatus. A similar pattern to that of the exploration data was observed, with a minimal activity observed between days 13 and 17. A radiation-induced hypothermia was also noticed over the same time period. (author)

  12. Behavioural consequences of an 8 Gy total body irradiation in mice: Regulation by interleukin-4

    Energy Technology Data Exchange (ETDEWEB)

    Van der Meeren, A.; Lebaron-Jacobs, L. [Inst. de Protection et de Surete Nucleaire, Dept. de Protection de la sante de l' Homme et de Dosimetrie, Section Autonome de Radiobiologie Appliquee a la Medecine, IPSN, Fontenay-aux-Roses (France)

    2001-02-01

    The effects of an 8 Gy {gamma} total body irradiation (TBI) on exploration and locomotion activities as well as temperature were studied in C57BL6/J mice. Survival, body weight, and blood cell counts were also assessed in irradiated mice treated with placebo or interleukin (IL)-4. The efficacy of IL-4 treatment on improvement in exploration activity was evaluated. The study was carried out from 3 h to 30 days following exposure. Our results showed a biphasic response to irradiation concerning the exploration activity of mice. Irradiated mice had reduced activity as early as 3 h after exposure, with recovery of activity within 24 h. The exploration activity again decreased 4 days after irradiation and the recovery occurred slowly after day 17. IL-4 ameliorated the exploration status in mice in both phases. The locomotion activity was studied using a telemetry apparatus. A similar pattern to that of the exploration data was observed, with a minimal activity observed between days 13 and 17. A radiation-induced hypothermia was also noticed over the same time period. (author)

  13. A reviewed technique for total body electron therapy using a Varian Clinac 2100C/D high dose rate treatment beam facility

    International Nuclear Information System (INIS)

    Oliver, L.D.; Xuereb, E.M.A.; Last, V.; Hunt, P.B.; Wilfert, A.

    1996-01-01

    Our (Royal North Shore Hospital) most recent linear accelerator acquisition is a Varian Clinac 2100C/D which has a high dose rate (approximately 25Gy per minute at 1 metre) total body electron option. We investigated the physical characteristics of the electron beam to develop a suitable method of treatment for total body electron therapy. The useful electron beam width is defined as 80cm above and below the reference height. Measurements of the electron dose received from the two angled electron beams showed a critical dependence on the gantry angles. The treatment protocol uses ten different patient angles, fractionated into directly opposing fields and treated seuqentially each day. A full cycle of treatment is completed in five days. (author)

  14. Pulmonary asbestos body counts and electron probe analysis of asbestos body cores in patients with mesothelioma: a study of 25 cases

    International Nuclear Information System (INIS)

    Roggli, V.L.; McGavran, M.H.; Subach, J.; Sybers, H.D.; Greenberg, S.D.

    1982-01-01

    Malignant mesotheliomas of the pleura and peritoneum are well-recognized risks of asbestos exposure. We determined the asbestos body content of the lungs from 24 cases of malignant mesothelioma (19 pleural, five peritoneal) and compared such to the content of lungs from 50 consecutive adult autopsies and four cases of overt asbestosis using a Clorox-digestion concentration technique. The cores of 90 asbestos bodies were examined by energy dispersive x-ray analysis and compared with similar data from 120 standard asbestos fibers and 20 fiberglass fibers. The malignant mesothelioma patients had asbestos body counts intermediate between those of the general population and those of patients with asbestosis, although some of the mesothelioma cases overlapped with the general population. These latter cases often lacked an identifiable occupational exposure to asbestos. EDXA studies demonstrated an amphibole core in 88 of the 90 asbestos bodies (amosite or crocidolite in 80 of 88, anthophyllite or tremolite in eight of 88), and chrysotile in two instances

  15. Counting radon tracks in Makrofol detectors with the 'image reduction and analysis facility' (IRAF) software package

    International Nuclear Information System (INIS)

    Hernandez, F.; Gonzalez-Manrique, S.; Karlsson, L.; Hernandez-Armas, J.; Aparicio, A.

    2007-01-01

    Makrofol detectors are commonly used for long-term radon ( 222 Rn) measurements in houses, schools and workplaces. The use of this type of passive detectors for the determination of radon concentrations requires the counting of the nuclear tracks produced by alpha particles on the detecting material. The 'image reduction and analysis facility' (IRAF) software package is a piece of software commonly used in astronomical applications. It allows detailed counting and mapping of sky sections where stars are grouped very closely, even forming clusters. In order to count the nuclear tracks in our Makrofol radon detectors, we have developed an inter-disciplinary application that takes advantage of the similitude that exist between counting stars in a dark sky and tracks in a track-etch detector. Thus, a low cost semi-automatic system has been set up in our laboratory which utilises a commercially available desktop scanner and the IRAF software package. A detailed description of the proposed semi-automatic method and its performance, in comparison to ocular counting, is described in detail here. In addition, the calibration factor for this procedure, 2.97+/-0.07kBqm -3 htrack -1 cm 2 , has been calculated based on the results obtained from exposing 46 detectors to certified radon concentrations. Furthermore, the results of a preliminary radon survey carried out in 62 schools in Tenerife island (Spain), using Makrofol detectors, counted with the mentioned procedure, are briefly presented. The results reported here indicate that the developed procedure permits a fast, accurate and unbiased determination of the radon tracks in a large number of detectors. The measurements carried out in the schools showed that the radon concentrations in at least 12 schools were above 200Bqm -3 and, in two of them, above 400Bqm -3 . Further studies should be performed at those schools following the European Union recommendations about radon concentrations in buildings

  16. Assessment of 137Cs exposure in Marshallese populations based on whole-body counting measurements (1989-1995)

    International Nuclear Information System (INIS)

    Sun, L.C.; Clinton, J.H.; Kaplan, E.; Meinhold, C.B.

    1996-01-01

    137 Cs has been measured in the Marshallese using a shadow shield whole-body counting system. One of the important techniques employed in assessing the internally deposited radionuclides for the Marshallese is whole-body counting. Data from the period of 1989 to 1995 have been analyzed in an attempt to assess current and potential future exposure to 137 Cs. During this period, 3,764 measurements were made at Encwetak, Rongelap, and Utirik. The cesium body burdens were assumed to be the result of a series of chronic intakes. It was also assumed that the measured cesium activity is maintained in the body over a 365-d interval. Committed effective dose to age 70 y, and the annual effective dose rate for each population, were estimated based on the approach recommended by the International Commission on Radiological Protection in its Publications 56 and 67. The average 137 Cs dose rates vary from one population to another; it was found to be correlated with the cesium concentration in the soil. The analysis indicates that, based on limited data, there is no statistical support for seasonal effect on 137 Cs uptake. The critical population group for cesium uptake is shown to be the male adult. Within the 6-y monitoring period, all exposures to 137 Cs were less than 0.2 mSv y -1 . A persistent average exposure of 2 μSv y -1 was determined for the Majuro residents

  17. A simple calibration of a whole-body counter for the measurement of total body potassium in humans

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El-Fiki, S.A.; El-Enany, N.; Youssef, S.K.; Aly, A.M.; Abbas, M.T.

    1992-01-01

    A simple calibration procedure for the Inshas whole body counter for evaluating total body potassium has been adopted. More than 120 Egyptian employees in the Nuclear Research Center (N.R.C.) were studied for their total body potassium (TBK). The potassium values were found to have an average of 2.85±0.57 g K kg -1 body weight for males and 2.62±0.52 g K kg -1 for females, which are higher than the recommended value given for reference man by ICRP. The TBK varied directly with body build index and is slightly sex dependent (Author)

  18. Influence of the type of milking and storage of milk on the chem ical composition, Somatic Cell Count and bacterial count Total

    Directory of Open Access Journals (Sweden)

    Aline Leite Peixoto

    2017-03-01

    Full Text Available The refrigeration of milk and the usage of mechanical milking are important to obtain milk in accordance with quality standards. In this work we evaluated the influence of the type of milking process and type of storage on the quality of the refrigerated milk. It was obtained 1363 refrigerated milk samples stored in single or collective expansion tanks, from manually or mechanically milked animals. The experiment was carried out in a 2x2 randomized factorial scheme. Two types of expansion tanks (single and collective and two types of milking (manual and mechanical. The average comparison test and Tukey test was carried out with 95% confidence. The levels of fat, protein, lactose and defatted dry extract, were evaluated according to the type of milking and type of milk storage. The values obtained were higher when compared to the values stabilished by the Ministry of Agriculture, Livestock and Food Supply. The level of milk fat was higher in samples with somatic cell count above 501,000 SC/mL. However, the levels of protein and defatted dry extract were higher in samples with somatic cell count below 500,000 SC/mL. The type of milking and the type of storage have influence on parameters related to milk quality such as levels of fat, protein, lactose and somatic cell count. The milk chemical composition revealed in accordance with the values stabilished by the Brazilian legislation. The total bacterial count did not vary with storage type nor the type of milking.

  19. Integral bounds for N-body total cross sections

    International Nuclear Information System (INIS)

    Osborn, T.A.; Bolle, D.

    1979-01-01

    We study the behavior of the total cross sections in the three- and N-body scattering problem. Working within the framework of the time-dependent two-Hilbert space scattering theory, we give a simple derivation of integral bounds for the total cross section for all processes initiated by the collision of two clusters. By combining the optical theorem with a trace identity derived by Jauch, Sinha, and Misra, we find, roughly speaking, that if the local pairwise interaction falls off faster than r -3 , then sigma/sub tot/(E) must decrease faster than E/sup -1/2/ at high energy. This conclusion is unchanged if one introduces a class of well-behaved three-body interactions

  20. Comparison of 24 hr total body radio-iodine retention for hypothyroid vs. thyrogen (rhTSH) stimulated whole body surveillance scan

    International Nuclear Information System (INIS)

    Jana, S.; Young, I.; Bukberg, P.; Luo, J.Q.; Dakhel, M.; Heiba, S.; El-Zeftawy, H.; Abdel-Dayem, H.M.

    2002-01-01

    Objective: Recently rhTSH has been used for WBS to avoid hypothyroid symptoms from T4/T3 withdrawal. There is limited data available in the current literature comparing total body radio-iodine clearance between hypothyroid pts and pts receiving rhTSH. Significant differences in radio-iodine clearance may influence the dose of radio-iodine required for diagnostic scanning or treatment of pts on a rhTSH protocol. Methods: To retrospectively compare the 24 hr total body I-123 retention in thyroid cancer pts who were made hypothyroid in preparation for radio-iodine scanning with the I-123 retention in pts who received thyrogen (rhTSH) but were maintained on thyroid hormone replacement. Inclusion criteria were as follows: Histologically diagnosed well diff. thyroid Ca s/p surgery and I-131 Rx in the past who were clinically disease free at the time of scanning. No abn. visible I-123 uptake on WBS and 24 hr neck uptake ≤ 1%. Tg level ≤ 2ng off T4/T3 or ≤ 2ng increase from basal level after rhTSH. Anti-Tg Ab negative. Serum Creatine ≤ 1.4 mg/dl. Serum ALT < 35, AST < 35. Total 78 pts were divided into the following 3 groups (Gp): Gp-1 (29 pts) received 2 IM inj. Of 0.9 mg rhTSH 24 and 48 hrs prior to oral dose of 10 mCi I-123. Gp-2 (30 pts) followed hypothyroid protocol i.e., off T4 ≥ 4 wks or T3 ≥ 10 days in order to achieve TSH ≥ 30 MIU/L. The dose of I-123 was 5 mCi. Gp-3 (19 pts) similar to Gp-2 i.e., hypothyroid but scanned using 10 mCi of I-123. Imaging protocol: Pts were scanned 4 hrs and 24 hrs after I-123 administration in a dual head gamma camera for 30 mins. Total body and neck counting were obtained from the geometric mean of Ant and Post images with appropriate decay correction. 24 hr total body retention (TBR) of I-123 were calculated and expressed in %, considering 100% at 4 hrs. Results: Demographic Profile of 3 Patient Groups. AST/ALT was < 35 and 24 hrs neck uptake was ≤ 1.0% all pts. Comparison of 24 hr % TBR of I-123 in 3 Patient Groups

  1. The water purification system for the low background counting test facility of the Borexino experiment at Gran Sasso

    International Nuclear Information System (INIS)

    Balata, M.; Cadonati, L.; Laubenstein, M.; Heusser, G.; Giammarchi, M.G.; Scardaoni, R.; Torri, V.; Cecchet, G.; De Bari, A.; Perotti, A.

    1996-01-01

    The Borexino experiment, for the study of solar neutrino physics, requires radiopurity at the level of 5 x 10 -16 g/g 238 U equivalent (or 6 x 10 -9 Bq/kg) on a detector mass of many tons of scintillator. Feasibility studies are performed in a counting test facility now operating at LNGS, which consists of 4 t of liquid scintillator viewed by 100 photomultipliers and shielded by 100 t of water. The accomplishment of this goal requires the shielding liquid, water, to be at the 10 -13 g/g contamination level (1.2 x 10 -6 Bq/kg) or better. This paper describes the water purification system; it consists of a combination of several purification processes to remove particulate, radioactive ions, dissolved gases and other impurities. Residual contaminations are measured by analytical or direct-counting techniques. For radon measurement, particularly challenging at this low activity levels, a low background counting method has been developed. (orig.)

  2. Total and Differential Leukocyte Counts in Relation to Incidence of Diabetes Mellitus: A Prospective Population-Based Cohort Study.

    Science.gov (United States)

    Borné, Yan; Smith, J Gustav; Nilsson, Peter M; Melander, Olle; Hedblad, Bo; Engström, Gunnar

    2016-01-01

    High concentrations of leukocytes in blood have been associated with diabetes mellitus. This prospective study aimed to explore whether total and differential leukocyte counts are associated with incidence of diabetes. A missense variant R262W in the SH2B3 (SH2B adaptor protein 3) gene, coding for a protein that negatively regulates hematopoietic cell proliferation, was also studied in relation to incidence of diabetes. Leukocyte count and its subtypes (neutrophils, lymphocytes and mixed cells) were analyzed in 26,667 men and women, 45-73 years old, from the population-based Malmö Diet and Cancer study. Information about the R262W polymorphism (rs3184504) in SH2B3 was genotyped in 24,489 subjects. Incidence of diabetes was studied during a mean follow-up of 14 years. Cox proportional hazards regression was used to examine incidence of diabetes by total and differential leukocyte counts. Mendelian randomization analysis using R262W as an instrumental variable was performed with two-stage least squares regression. A total of 2,946 subjects developed diabetes during the follow-up period. After taking several possible confounders into account, concentrations of total leukocyte count, neutrophils and lymphocytes were all significantly associated with incidence of diabetes. The adjusted hazard ratios (95% confidence interval; quartile 4 vs quartile 1) were 1.37 (1.22-1.53) for total leukocytes, 1.33 (1.19-1.49) for neutrophils and 1.29 (1.15-1.44) for lymphocytes. The R262W polymorphism was strongly associated with leukocytes (0.11x109 cells/l per T allele, p = 1.14 x10-12), lymphocytes (p = 4.3 x10-16), neutrophils (p = 8.0 x10-6) and mixed cells (p = 3.0 x10-6). However, there was no significant association between R262W and fasting glucose, HbA1c or incidence of diabetes. Concentrations of total leukocytes, neutrophils and lymphocytes are associated with incidence of diabetes. However, the lack of association with the R262W polymorphism suggests that the associations

  3. Galectin-3 levels relate in children to total body fat, abdominal fat, body fat distribution, and cardiac size.

    Science.gov (United States)

    Dencker, Magnus; Arvidsson, Daniel; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola

    2018-03-01

    Galectin-3 has recently been proposed as a novel biomarker for cardiovascular disease in adults. The purpose of this investigation was to assess relationships between galectin-3 levels and total body fat, abdominal fat, body fat distribution, aerobic fitness, blood pressure, left ventricular mass, left atrial size, and increase in body fat over a 2-year period in a population-based sample of children. Our study included 170 children aged 8-11 years. Total fat mass and abdominal fat were measured by dual-energy x-ray absorptiometry (DXA). Body fat distribution was expressed as abdominal fat/total fat mass. Maximal oxygen uptake was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure and pulse pressure were measured. Left atrial size, left ventricular mass, and relative wall thickness were measured by echocardiography. Frozen serum samples were analyzed for galectin-3 by the Proximity Extension Assay technique. A follow-up DXA scan was performed in 152 children 2 years after the baseline exam. Partial correlations, with adjustment for sex and age, between galectin-3 versus body fat measurements indicated weak to moderate relationships. Moreover, left atrial size, left ventricular mass, and relative wall thickness and pulse pressure were also correlated with galectin-3. Neither systolic blood pressure nor maximal oxygen uptake was correlated with galectin-3. There was also a correlation between galectin-3 and increase in total body fat over 2 years, while no such correlations were found for the other fat measurements. More body fat and abdominal fat, more abdominal body fat distribution, more left ventricular mass, and increased left atrial size were all associated with higher levels of galectin-3. Increase in total body fat over 2 years was also associated with higher levels of galectin-3. What is Known: • Galectin-3 has been linked to obesity and been proposed to be a novel biomarker

  4. Evaluation of a standardized procedure for [corrected] microscopic cell counts [corrected] in body fluids.

    Science.gov (United States)

    Emerson, Jane F; Emerson, Scott S

    2005-01-01

    A standardized urinalysis and manual microscopic cell counting system was evaluated for its potential to reduce intra- and interoperator variability in urine and cerebrospinal fluid (CSF) cell counts. Replicate aliquots of pooled specimens were submitted blindly to technologists who were instructed to use either the Kova system with the disposable Glasstic slide (Hycor Biomedical, Inc., Garden Grove, CA) or the standard operating procedure of the University of California-Irvine (UCI), which uses plain glass slides for urine sediments and hemacytometers for CSF. The Hycor system provides a mechanical means of obtaining a fixed volume of fluid in which to resuspend the sediment, and fixes the volume of specimen to be microscopically examined by using capillary filling of a chamber containing in-plane counting grids. Ninety aliquots of pooled specimens of each type of body fluid were used to assess the inter- and intraoperator reproducibility of the measurements. The variability of replicate Hycor measurements made on a single specimen by the same or different observers was compared with that predicted by a Poisson distribution. The Hycor methods generally resulted in test statistics that were slightly lower than those obtained with the laboratory standard methods, indicating a trend toward decreasing the effects of various sources of variability. For 15 paired aliquots of each body fluid, tests for systematically higher or lower measurements with the Hycor methods were performed using the Wilcoxon signed-rank test. Also examined was the average difference between the Hycor and current laboratory standard measurements, along with a 95% confidence interval (CI) for the true average difference. Without increasing labor or the requirement for attention to detail, the Hycor method provides slightly better interrater comparisons than the current method used at UCI. Copyright 2005 Wiley-Liss, Inc.

  5. Total body fat as a possible indicator of metabolic syndrome in adults

    Directory of Open Access Journals (Sweden)

    Edgar Navarro Lechuga

    2016-09-01

    Full Text Available Introduction: The metabolic syndrome is a set of factors related to insulin resistance, which increases the likelihood of coronary events. It is important timely onset identifying to reduce its prevalence. Objective: To explore the percentage of total body fat as indicator of metabolic syndrome in adults from Soledad, Colombia. Material and Methods: Cross-sectional study. n=99 adults (non-pregnant, nor subjects with psychomotor disturbances. Blood samples were taken: total cholesterol, HDL; triglycerides and glucose. Waist circumference, Body Mass Index and body fat by bioimpedance and skinfold thickness were measured. Diagnosis of metabolic syndrome was made according to NHLBI/AHA, ATP III and IDF criteria. Subjects with and without metabolic syndrome according to total body fat averages were compared. Results: The average percentage of body fat was higher (p0.05 in the classification according to ATP III in women, where the average fat percentage was 39.31 % in those with metabolic syndrome and 37.7% in those not suffering. Conclusions: Subjects with metabolic syndrome have higher mean total body fat, significantly, compared with those who did not, so it could be considered the values of total body fat obtained by bioimpedance as future indicators of metabolic syndrome, both as screening and control.

  6. From whole-body counting to imaging: The computer aided collimation gamma camera project (CACAO)

    Energy Technology Data Exchange (ETDEWEB)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Ballongue, P

    2000-07-01

    Whole-body counting is the method of choice for in vivo detection of contamination. To extend this well established method, the possible advantages of imaging radiocontaminants are examined. The use of the CACAO project is then studied. A comparison of simulated reconstructed images obtained by the CACAO project and by a conventional gamma camera used in nuclear medicine follows. Imaging a radionuclide contaminant with a geometrical sensitivity of 10{sup -2} seems possible in the near future. (author)

  7. From whole-body counting to imaging: The computer aided collimation gamma camera project (CACAO)

    International Nuclear Information System (INIS)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Ballongue, P.

    2000-01-01

    Whole-body counting is the method of choice for in vivo detection of contamination. To extend this well established method, the possible advantages of imaging radiocontaminants are examined. The use of the CACAO project is then studied. A comparison of simulated reconstructed images obtained by the CACAO project and by a conventional gamma camera used in nuclear medicine follows. Imaging a radionuclide contaminant with a geometrical sensitivity of 10 -2 seems possible in the near future. (author)

  8. Calcium metabolism in fluorosis and endemic genu valgum using radioactive tracer, whole body counting and radioimmunoassay

    International Nuclear Information System (INIS)

    Narasinga Rao, B.

    1979-11-01

    Endemic fluorosis with extensive skeletal changes has been reported from several parts of India. In recent years a new condition, endemic genu valgum, has been recognized in one of these areas. In both conditions osteosclerosis, particularly of the spine, has been observed, but in genu valgum the most distinctive pathology is osteoporosis in bones of the extremities and presumably as a result the ''knock knees'' that give the syndrome its name. In this project certain aspects of calcium metabolism were investigated in endemic fluorosis and genu valgum and in appropriate control subjects. Calcium kinetics were studied by intravenously injecting a tracer dose of 47 Ca and following for 10 days thereafter the concentration of the tracer in serum and excreta, as well as its total retention in the body (the latter measured by whole body counting). In addition calcium balance was measured on some of the subjects while resident in a metabolic ward. Statistical analysis of the results showed in general a higher metabolic activity of calcium in the fluorosis and genu valgum cases than in the controls (specifically, higher ''turnover'' of calcium in the blood pool and an apparently elevated bone mineralization rate). Whole body retention was somewhat greater in the patients than in the controls. Several measurements were also performed relative to blood chemistry, and in particular the serum concentration of 25-OHD 3 (a metabolite of vitamin D) was measured. There was no evidence that vitamin D deficiency played a significant role in the causation of genu valgum

  9. Study on advancement of in vivo counting using mathematical simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kinase, Sakae [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-05-01

    To obtain an assessment of the committed effective dose, individual monitoring for the estimation of intakes of radionuclides is required. For individual monitoring of exposure to intakes of radionuclides, direct measurement of radionuclides in the body - in vivo counting- is very useful. To advance in a precision in vivo counting which fulfills the requirements of ICRP 1990 recommendations, some problems, such as the investigation of uncertainties in estimates of body burdens by in vivo counting, and the selection of the way to improve the precision, have been studied. In the present study, a calibration technique for in vivo counting application using Monte Carlo simulation was developed. The advantage of the technique is that counting efficiency can be obtained for various shapes and sizes that are very difficult to change for phantoms. To validate the calibration technique, the response functions and counting efficiencies of a whole-body counter installed in JAERI were evaluated using the simulation and measurements. Consequently, the calculations are in good agreement with the measurements. The method for the determination of counting efficiency curves as a function of energy was developed using the present technique and a physiques correction equation was derived from the relationship between parameters of correction factor and counting efficiencies of the JAERI whole-body counter. The uncertainties in body burdens of {sup 137}Cs estimated with the JAERI whole-body counter were also investigated using the Monte Carlo simulation and measurements. It was found that the uncertainties of body burdens estimated with the whole-body counter are strongly dependent on various sources of uncertainty such as radioactivity distribution within the body and counting statistics. Furthermore, the evaluation method of the peak efficiencies of a Ge semi-conductor detector was developed by Monte Carlo simulation for optimum arrangement of Ge semi-conductor detectors for

  10. Estimation of DMFT, Salivary Streptococcus Mutans Count, Flow Rate, Ph, and Salivary Total Calcium Content in Pregnant and Non-Pregnant Women: A Prospective Study.

    Science.gov (United States)

    Kamate, Wasim Ismail; Vibhute, Nupura Aniket; Baad, Rajendra Krishna

    2017-04-01

    Pregnancy, a period from conception till birth, causes changes in the functioning of the human body as a whole and specifically in the oral cavity that may favour the emergence of dental caries. Many studies have shown pregnant women at increased risk for dental caries, however, specific salivary caries risk factors and the particular period of pregnancy at heightened risk for dental caries are yet to be explored and give a scope of further research in this area. The aim of the present study was to assess the severity of dental caries in pregnant women compared to non-pregnant women by evaluating parameters like Decayed, Missing, Filled Teeth (DMFT) index, salivary Streptococcus mutans count, flow rate, pH and total calcium content. A total of 50 first time pregnant women in the first trimester were followed during their second trimester, third trimester and postpartum period for the evaluation of DMFT by World Health Organization (WHO) scoring criteria, salivary flow rate by drooling method, salivary pH by pH meter, salivary total calcium content by bioassay test kit and salivary Streptococcus mutans count by semiautomatic counting of colonies grown on Mitis Salivarius (MS) agar supplemented by 0.2U/ml of bacitracin and 10% sucrose. The observations of pregnant women were then compared with same parameters evaluated in the 50 non-pregnant women. Paired t-test and Wilcoxon sign rank test were performed to assess the association between the study parameters. Evaluation of different caries risk factors between pregnant and non-pregnant women clearly showed that pregnant women were at a higher risk for dental caries. Comparison of caries risk parameters during the three trimesters and postpartum period showed that the salivary Streptococcus mutans count had significantly increased in the second trimester , third trimester and postpartum period while the mean pH and mean salivary total calcium content decreased in the third trimester and postpartum period. These

  11. Estimation of DMFT, Salivary Streptococcus Mutans Count, Flow Rate, Ph, and Salivary Total Calcium Content in Pregnant and Non-Pregnant Women: A Prospective Study

    Science.gov (United States)

    Vibhute, Nupura Aniket; Baad, Rajendra Krishna

    2017-01-01

    Introduction Pregnancy, a period from conception till birth, causes changes in the functioning of the human body as a whole and specifically in the oral cavity that may favour the emergence of dental caries. Many studies have shown pregnant women at increased risk for dental caries, however, specific salivary caries risk factors and the particular period of pregnancy at heightened risk for dental caries are yet to be explored and give a scope of further research in this area. Aim The aim of the present study was to assess the severity of dental caries in pregnant women compared to non-pregnant women by evaluating parameters like Decayed, Missing, Filled Teeth (DMFT) index, salivary Streptococcus mutans count, flow rate, pH and total calcium content. Materials and Methods A total of 50 first time pregnant women in the first trimester were followed during their second trimester, third trimester and postpartum period for the evaluation of DMFT by World Health Organization (WHO) scoring criteria, salivary flow rate by drooling method, salivary pH by pH meter, salivary total calcium content by bioassay test kit and salivary Streptococcus mutans count by semiautomatic counting of colonies grown on Mitis Salivarius (MS) agar supplemented by 0.2U/ml of bacitracin and 10% sucrose. The observations of pregnant women were then compared with same parameters evaluated in the 50 non-pregnant women. Paired t-test and Wilcoxon sign rank test were performed to assess the association between the study parameters. Results Evaluation of different caries risk factors between pregnant and non-pregnant women clearly showed that pregnant women were at a higher risk for dental caries. Comparison of caries risk parameters during the three trimesters and postpartum period showed that the salivary Streptococcus mutans count had significantly increased in the second trimester, third trimester and postpartum period while the mean pH and mean salivary total calcium content decreased in the third

  12. Quantitative monitoring of the fluorination process by neutron counting

    International Nuclear Information System (INIS)

    Russo, P.A.; Appert, Q.D.; Biddle, R.S.; Kelley, T.A.; Martinez, M.M.; West, M.H.

    1993-01-01

    Plutonium metal is produced by reducing PuF 4 prepared from PuO 2 by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron (α,n) reactions on fluorine targets compared to the (more than 100 times) smaller α,n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. Neutrons are counted with polyethylene-moderated 3 He-gas proportional counters. Results include a calibration of the real-time neutron-count-rate indicator for the extent of fluorination using reference values obtained from destructive analysis of samples from the blended fluoroinated batch

  13. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  14. Organization and staffing of the regulatory body for nuclear facilities. Safety guide

    International Nuclear Information System (INIS)

    2005-01-01

    The purpose of this safety guide is to provide recommendations for national authorities on the appropriate management system, organization and staffing for the regulatory body responsible for the regulation of nuclear facilities in order to achieve compliance with the applicable safety requirements. This safety guide covers the organization and staffing in relation to nuclear facilities such as: enrichment and fuel manufacturing plants. Nuclear power plants. Other reactors such as research reactors and critical assemblies. Spent fuel reprocessing plants. And radioactive waste management facilities such as treatment, storage and disposal facilities. This safety guide also covers issues related to the decommissioning of nuclear facilities, the closure of waste disposal facilities and site rehabilitation

  15. Total Body Opacification 'Technique Neonatal Adrenal Haemorrhage

    African Journals Online (AJOL)

    1971-12-11

    Dec 11, 1971 ... A case is reported illustrating the possible usefulness of total body opacification in the diagnosis of neonatal adrenal haemorrhage. To derive maximum benefit from this principle, the routine use of an early film coupled with high dosage is urged whenever an intravenous pyelogram is performed for ...

  16. Antiaging Effects of an Intensive Mind and Body Therapeutic Program through Enhancement of Telomerase Activity and Adult Stem Cell Counts.

    Science.gov (United States)

    Rao, Krishna S; Chakraharti, Swarup K; Dongare, Vaishali S; Chetana, K; Ramirez, Christina M; Koka, Prasad S; Deb, Kaushik D

    2015-01-01

    Key modalities of integrative medicine known to rejuvenate the mind and body are meditation, yoga, and controlled diet. It has been shown previously that intensive or prolonged mind and body therapies (MBT) may have beneficial effects on the well-being of healthy people and in patients. Telomerase activity and levels of peripheral blood adult pluripotent stem cells (PB-APSC) are reliable markers of long-term well-being that are known to decrease with age. The objective of this study is to understand the effect of our MBT program on telomerase activity and stem cells in blood collected from the participants. Here, we have investigated the effects of an intensive three weeks MBT retreat on telomerase activity and the peripheral blood stem cells in participants before and after the MBT. A total of 108 people were enrolled in the study; 38 men and 70 women (aged 18-90) randomly assigned for the study. Telomerase activity was greater in retreat participants at the end of the MBT retreat. About 45% of people showed more than one-fold increase of telomerase activity after our MBT program. Furthermore, about 27% of people showed more pronounced fold increase (2-fold) in telomerase activity after the MBT. In addition, a substantial percentage of people (about 90%) exhibited increased stem cell counts after the MBT. The data suggest increased telomerase activity and stem cells count in peripheral blood from MBT retreat participants that may lead to increased longevity and better quality of life at latter age.

  17. The use of flow cytometry to accurately ascertain total and viable counts of Lactobacillus rhamnosus in chocolate.

    Science.gov (United States)

    Raymond, Yves; Champagne, Claude P

    2015-04-01

    The goals of this study were to evaluate the precision and accuracy of flow cytometry (FC) methodologies in the evaluation of populations of probiotic bacteria (Lactobacillus rhamnosus R0011) in two commercial dried forms, and ascertain the challenges in enumerating them in a chocolate matrix. FC analyses of total (FC(T)) and viable (FC(V)) counts in liquid or dried cultures were almost two times more precise (reproducible) than traditional direct microscopic counts (DCM) or colony forming units (CFU). With FC, it was possible to ascertain low levels of dead cells (FC(D)) in fresh cultures, which is not possible with traditional CFU and DMC methodologies. There was no interference of chocolate solids on FC counts of probiotics when inoculation was above 10(7) bacteria per g. Addition of probiotics in chocolate at 40 °C resulted in a 37% loss in viable cells. Blending of the probiotic powder into chocolate was not uniform which raised a concern that the precision of viable counts could suffer. FCT data can serve to identify the correct inoculation level of a sample, and viable counts (FCV or CFU) can subsequently be better interpreted. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  18. Acute Radiation Syndrome Severity Score System in Mouse Total-Body Irradiation Model.

    Science.gov (United States)

    Ossetrova, Natalia I; Ney, Patrick H; Condliffe, Donald P; Krasnopolsky, Katya; Hieber, Kevin P

    2016-08-01

    Radiation accidents or terrorist attacks can result in serious consequences for the civilian population and for military personnel responding to such emergencies. The early medical management situation requires quantitative indications for early initiation of cytokine therapy in individuals exposed to life-threatening radiation doses and effective triage tools for first responders in mass-casualty radiological incidents. Previously established animal (Mus musculus, Macaca mulatta) total-body irradiation (γ-exposure) models have evaluated a panel of radiation-responsive proteins that, together with peripheral blood cell counts, create a multiparametic dose-predictive algorithm with a threshold for detection of ~1 Gy from 1 to 7 d after exposure as well as demonstrate the acute radiation syndrome severity score systems created similar to the Medical Treatment Protocols for Radiation Accident Victims developed by Fliedner and colleagues. The authors present a further demonstration of the acute radiation sickness severity score system in a mouse (CD2F1, males) TBI model (1-14 Gy, Co γ-rays at 0.6 Gy min) based on multiple biodosimetric endpoints. This includes the acute radiation sickness severity Observational Grading System, survival rate, weight changes, temperature, peripheral blood cell counts and radiation-responsive protein expression profile: Flt-3 ligand, interleukin 6, granulocyte-colony stimulating factor, thrombopoietin, erythropoietin, and serum amyloid A. Results show that use of the multiple-parameter severity score system facilitates identification of animals requiring enhanced monitoring after irradiation and that proteomics are a complementary approach to conventional biodosimetry for early assessment of radiation exposure, enhancing accuracy and discrimination index for acute radiation sickness response categories and early prediction of outcome.

  19. Serum protein concentration in low-dose total body irradiation of normal and malnourished rats

    International Nuclear Information System (INIS)

    Viana, W.C.M.; Lambertz, D.; Borges, E.S.; Neto, A.M.O.; Lambertz, K.M.F.T.; Amaral, A.

    2016-01-01

    Among the radiotherapeutics' modalities, total body irradiation (TBI) is used as treatment for certain hematological, oncological and immunological diseases. The aim of this study was to evaluate the long-term effects of low-dose TBI on plasma concentration of total protein and albumin using prematurely and undernourished rats as animal model. For this, four groups with 9 animals each were formed: Normal nourished (N); Malnourished (M); Irradiated Normal nourished (IN); Irradiated Malnourished (IM). At the age of 28 days, rats of the IN and IM groups underwent total body gamma irradiation with a source of cobalt-60. Total protein and Albumin in the blood serum was quantified by colorimetry. This research indicates that procedures involving low-dose total body irradiation in children have repercussions in the reduction in body-mass as well as in the plasma levels of total protein and albumin. Our findings reinforce the periodic monitoring of total serum protein and albumin levels as an important tool in long-term follow-up of pediatric patients in treatments associated to total body irradiation. - Highlights: • Low-dose total body irradiation (TBI) in children have repercussions in their body-mass. • Long-term total protein and albumin levels are affected by TBI. • The monitoring of total protein and albumin levels are useful in the follow-up of TBI pediatric patients.

  20. Total body irradiation as a form of preparation for bone marrow transplantation

    International Nuclear Information System (INIS)

    Inoue, Toshihiko

    1987-01-01

    The history of total body irradiation and bone marrow transplantation is surprisingly old. Following the success of Thomas et al. in the 1970s, bone marrow transplantation appeared to be the sole curative treatment modality for high-risk leukemia. A supralethal dose of total body irradiation was widely accepted as a form of preparation for bone marrow transplantation. In this paper, I described the present status of bone marrow transplantation for leukemia patients in Japan based on the IVth national survey. Since interstitial pneumonitis was one of the most life threatening complications after bone marrow transplantation, I mentioned the dose, dose-rate and fraction of total body irradiation in more detail. In addition, I dealt with some problems of the total body irradiation, such as dose prescription, compensating contour as well as inhomogeneity, and shielding for the highrisk organs. (author) 82 refs

  1. Total body irradiation therapy for thymectomized myasthenic patients and immunological evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Yamanaka, Nobukazu; Tanaka, Masayuki; Kurihara, Teruyuki (Miyazaki Medical College (Japan))

    1983-06-01

    Three patients with intractable myasthenia gravis (MG) were treated with total body irradiation (TBI). All the three patients had been unstable after extended thymectomy and poorly responding to prednisolone therapy. Radiation therapy consisted of 10 doses of 10 rads/day given over five weeks. After the radiation therapy the three patients improved clinically, and an objective parameter, area of M-waves also improved. No significant side effects were noted. TBI therapy can be considered as a safe method to induce selective reduction of circulating lymphocytes. This was indeed achieved, as evidenced by a drop of the lymphocyte counts to the levels of 20-40 % of the pretreatment level. The effects were persistent over twelve weeks. Early radiosensitivity of B lymphocytes were recognized. The levels of T..gamma.. cells were low before TBI therapy, increasing gradually during TBI therapy and returned to normal range after twelve weeks. Serum anti-AChR antibody titers decreased in all the cases, but it was impossible to determine whether the decrement was due to the therapy or natural course after thymectomy. Two of our three cases had a significant percentage decrement of the titers after TBI therapy. We suggest that TBI therapy is a safe method of immunosupperssive treatment for the myasthenic patients after thymectomy.

  2. Total body irradiation therapy for thymectomized myasthenic patients and immunological evaluations

    International Nuclear Information System (INIS)

    Yamanaka, Nobukazu; Tanaka, Masayuki; Kurihara, Teruyuki

    1983-01-01

    Three patients with intractable myasthenia gravis (MG) were treated with total body irradiation (TBI). All the three patients had been unstable after extended thymectomy and poorly responding to prednisolone therapy. Radiation therapy consisted of 10 doses of 10 rads/day given over five weeks. After the radiation therapy the three patients improved clinically, and an objective parameter, area of M-waves also improved. No significant side effects were noted. TBI therapy can be considered as a safe method to induce selective reduction of circulating lymphocytes. This was indeed achieved, as evidenced by a drop of the lymphocyte counts to the levels of 20-40 % of the pretreatment level. The effects were persistent over twelve weeks. Early radiosensitivity of B lymphocytes were recognized. The levels of Tγ cells were low before TBI therapy, increasing gradually during TBI therapy and returned to normal range after twelve weeks. Serum anti-AChR antibody titers decreased in all the cases, but it was impossible to determine whether the decrement was due to the therapy or natural course after thymectomy. Tow of our three cases had a significant percentage decrement of the titers after TBI therapy. We suggest that TBI therapy is a safe method of immunosupperssive treatment for the myasthenic patients after thymectomy. (author)

  3. Atlas of total body radionuclide imaging. Volume I and II

    International Nuclear Information System (INIS)

    Fordham, E.W.; Ali, A.; Turner, D.A.; Charters, J.

    1982-01-01

    This two-volume work on total body imaging may well be regarded by future historians of nuclear medicine as representing the high points in the art of total body imaging in clinical nuclear medicine. With regard to information content and volume, it is the largest collection of well-interpreted, beautifully reproduced, total body images available to date. The primary goal of this atlas is to demonstrate patterns of abnormality in both typical and less typical variations. This goal is accomplished with many well-described examples of technical artifacts, of normal variants, of common and of rare diseases, and of pitfalls in interpretations. Volume I is entirely dedicated to skeletal imaging with Tc-99m labeled phosphates or phosphonates. The volume is divided into 22 chapters, which include chapters on methodology and instrumentation, chapters on the important bone diseases and other topics such as a treatise on false-negative and false-positive scans, and soft tissue and urinary tract abnormalities recognizable on bone scintigrams

  4. How much locomotive activity is needed for an active physical activity level: analysis of total step counts

    Directory of Open Access Journals (Sweden)

    Ohkawara Kazunori

    2011-11-01

    Full Text Available Abstract Background Although physical activity recommendations for public health have focused on locomotive activity such as walking and running, it is uncertain how much these activities contribute to overall physical activity level (PAL. The purpose of the present study was to determine the contribution of locomotive activity to PAL using total step counts measured in a calorimeter study. Methods PAL, calculated as total energy expenditure divided by basal metabolic rate, was evaluated in 11 adult men using three different conditions for 24-hour human calorimeter measurements: a low-activity day (L-day targeted at a low active level of PAL (1.45, and a high-frequency moderate activity day (M-day or a high-frequency vigorous activity day (V-day targeted at an active level of PAL (1.75. These subjects were permitted only light activities except prescribed activities. In a separate group of 41 adults, free-living PAL was evaluated using doubly-labeled water (DLW. In both experiments, step counts per day were also measured using an accelerometer. Results In the human calorimeter study, PAL and step counts were 1.42 ± 0.10 and 8,973 ± 543 steps/d (L-day, 1.82 ± 0.14 and 29,588 ± 1,126 steps/d (M-day, and 1.74 ± 0.15 and 23,755 ± 1,038 steps/d (V-day, respectively. In the DLW study, PAL and step counts were 1.73 ± 0.15 and 10,022 ± 2,605 steps/d, and there was no significant relationship between PAL and daily step counts. Conclusions These results indicate that an enormous number of steps are needed for an active level of PAL if individuals extend physical activity-induced energy expenditure by only locomotive activity. Therefore, non-locomotive activity such as household activity should also play a significant role in increasing PAL under free-living conditions.

  5. Gigapixel photography for skin cancer surveillance: a novel alternative to total-body photography.

    Science.gov (United States)

    Mikailov, Anar; Blechman, Adam

    2013-11-01

    There is substantial evidence supporting the use of cutaneous imaging in combination with standard total-body skin examinations for early detection and treatment of melanoma. In the last 2 decades, total-body photography (TBP) has been widely used in combination with standard total-body skin examinations for active skin cancer surveillance with proven clinical utility; however, the groundbreaking image detail provided by gigapixel photography (GP) could improve dermatologists' ability to monitor suspicious lesions and therefore could serve a critical role in supplementing traditional total-body skin examinations for skin cancer surveillance. Although it has been successfully implemented in other fields, future studies are required to determine the effectiveness of GP in dermatology.

  6. Sperm counts may have declined in young university students in Southern Spain

    DEFF Research Database (Denmark)

    Mendiola, Jaime; Jørgensen, Niels; Mínguez-Alarcón, Lidia

    2013-01-01

    Several studies have investigated temporal trends in semen quality in Northern Europe, but none has examined this question in Southern Europe. A prior study conducted in Almeria Province (Southern Spain) reported higher sperm count and concentration among Spanish young men recruited from 2001......, Body mass index (BMI), presence of varicocoele and prenatal exposure to tobacco) to look for a birth-cohort effect over the combined study period (2001-2011). Sperm concentration and total sperm count declined significantly with year of birth in the pooled analysis (β = -0.04 and β = -0...

  7. The usefulness of measurement of whole body count in assessing bone marrow metastasis in cancer patients with increased periarticular bone uptake on follow-up bone scan: a comparison with bone marrow scan

    International Nuclear Information System (INIS)

    Jin, Seong Chan; Choi, Yun Young; Cho, Suk Shin

    2003-01-01

    Increased periarticular uptake could be associated with peripheral bone marrow expansion in cancer patients with axial bone marrow metastasis. We compared bone scan and bone marrow scan to investigate whether the increased whole body count in patients with increased periarticular uptake on bone scan is useful in the diagnosis of axial marrow metastasis, and evaluate the role of additional bone marrow scan in these cases. Twelve patients with malignant diseases who showed increased periarticular uptake on bone scan were included. Whole body count was measured on bone scan and it is considered to be increased when the count is more than twice of other patients. Bone marrow scan was taken within 3-7 days. Five hematologic malignancy, 3 stomach cancer, 2 breast cancer, 1 prostate cancer and 1 lung canner were included. All three patients with increased whole body count on bone scan showed axial marrow suppression and peripheral marrow expansion. Eight of 9 patients without increased whole body count showed axial marrow suppression and peripheral marrow expansion. One turned out to be blastic crisis of chronic myelogeneous leukemia, and seven showed normal axial marrow with peripheral marrow expansion in chronic anemia of malignancy. The last one without increased whole body count showed normal bone marrow scan finding. Increased whole body count on bone scan could be a clue to axial bone marrow metastasis in cancer patients with increased periarticular uptake, and bone marrow scan is a valuable method for differential diagnosis in these cases

  8. Gamma-spectrometric and total alpha-beta counting methods for radioactivity analysis of deuterium depleted water

    International Nuclear Information System (INIS)

    Ferdes, Ov. S.; Mladin, C.; Vladu, Mihaela; Bulubasa, G.; Bidica, N.

    2008-01-01

    According to national regulations, as well as to the EU directive on the quality of drinking water, the radionuclide concentrations represent some of the drinking water quality parameters. Among the most important radioactivity content parameters are: the total alpha and total beta concentration (Bq/l); K-40 content, and the gamma-nuclides volume activities. The paper presents the measuring methods for low-level total alpha and/or beta counting of volume samples, as well as the high-resolution gamma-ray spectrometric method used to measure the volume activity of nuclides in drinking water. These methods are applied to monitor the radioactivity content and quality of the QLARIVIA brand of Deuterium depleted water (DDW). There are discussed the performances of these applied methods as well as some preliminary results. (authors)

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  10. Realistic torso phantom for calibration of in-vivo transuranic-nuclide counting facilities

    Energy Technology Data Exchange (ETDEWEB)

    Shirotani, Takashi

    1988-11-01

    A realistic torso phantom with average body size of Japanese adult males has been developed for the calibration of counting systems used for in-vivo measurements of plutonium and other actinides. The phantom contains removable model organs (lungs, liver, kidneys and heart), model trachea and artificial rib cage, and also includes chest plates that can be placed over the chest to simulate wide range adipose/muscle ratio in the human chest. Tissue substitutes used in the phantom were made of polyurethane with different concentrations of ester of phosphoric acid. Model lungs were made of foamed polyurethane with small quantities of the additive, and the artificial rib cage was made of epoxy resin with calcium carbonate. The experimental data have shown that the phantom can be used as a standard phantom for the calibration.

  11. 137Cs exposure in the Marshallese populations: an assessment based on whole-body counting measurements (1989-1994).

    Science.gov (United States)

    Sun, L C; Clinton, J H; Kaplan, E; Meinhold, C B

    1997-07-01

    The Marshall Islands were the site of numerous tests of nuclear weapons by the United States. From 1946 to 1958, nuclear devices were detonated at Enewetak and Bikini Atolls. Following the inadvertent contamination of the northern islands downwind of the 1954 Bravo Test, Brookhaven National Laboratory became involved in the medical care and the radiological safety of the affected populations. One important technique employed in assessing the internally deposited radionuclides is whole-body counting. To estimate current and future exposures to 137Cs, data from 1989 to 1994 were analyzed and are reported in this paper. During this period, 3,618 measurements were made for the Marshallese. The cesium body contents were assumed to result from a series of chronic intakes. Also, it was assumed that cesium activity in the body reaches a plateau that is maintained over 365 d. We estimated the annual effective dose rate for each population, derived from the recommendations of the International Commission on Radiological Protection. The average 137Cs uptake measured by the whole-body counting method varies from one population to another; it was consistent with measurements of external exposure rate. The analysis, though based on limited data, indicates that there is no statistical support for a seasonal effect on 137Cs uptake. The critical population group for cesium uptake is adult males. Within the 5-y monitoring period, all internal exposures to 137Cs were less than 0.2 mSv y(-1). Similarly, a persistent average cesium effective dose rate of 2 microSv y(-1) was determined for Majuro residents.

  12. Elevated Serum Osmolality and Total Water Deficit Indicate Impaired Hydration Status in Residents of Long-Term Care Facilities Regardless of Low or High Body Mass Index.

    Science.gov (United States)

    Marra, Melissa Ventura; Simmons, Sandra F; Shotwell, Matthew S; Hudson, Abbie; Hollingsworth, Emily K; Long, Emily; Kuertz, Brittany; Silver, Heidi J

    2016-05-01

    Dehydration is typically associated with underweight and malnutrition in long-term care (LTC) settings. Evidence is lacking regarding the influence of the rising prevalence of overweight and obesity on risk factors, prevalence, and presentation of dehydration. The aim of this study was to objectively assess hydration status and the adequacy of total water intake, and determine relationships between hydration status, total water intake, and body mass index (BMI) in LTC residents. A cross-sectional analysis of baseline data was performed. Baseline data from 247 subjects recruited from eight community-based LTC facilities participating in two randomized trials comparing nutrient and cost-efficacy of between-meal snacks vs oral nutrition supplements (ONS). Hydration status was assessed by serum osmolality concentration and total water intakes were quantified by weighed food, beverage, water, and ONS intake. Simple and multiple linear regression methods were applied. Forty-nine (38.3%) subjects were dehydrated (>300 mOsm/kg) and another 39 (30.5%) had impending dehydration (295 to 300 mOsm/kg). The variance in serum osmolality was significantly accounted for by blood urea nitrogen level, mental status score, and having diabetes (R(2)=0.46; PTotal water intake averaged 1,147.2±433.1 mL/day. Thus, 96% to 100% of subjects did not meet estimated requirements, with a deficit range of 700 to 1,800 mL/day. The variance in total water intake was significantly accounted for by type of liquid beverages (thin vs thick), type of ONS, total energy intake, total activities of daily living dependence, sex, and BMI (R(2)=0.56; Ptotal water intake is prevalent in LTC residents across all BMI categories. Type of liquid beverages, type of ONS, and type of between-meal snacks are factors that could be targeted for nutrition interventions designed to prevent or reverse dehydration. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  13. Can Serum Albumin Level and Total Lymphocyte Count be Surrogates for Malnutrition to Predict Wound Complications After Total Knee Arthroplasty?

    Science.gov (United States)

    Morey, Vivek M; Song, Young Dong; Whang, Ji Sup; Kang, Yeon Gwi; Kim, Tae Kyun

    2016-06-01

    Although the serum albumin level and total lymphocyte count (TLC) have been reported as valid and reliable markers for defining malnutrition, their cutoff levels and predictive values for wound complications in patients undergoing total knee arthroplasty (TKA) remain questionable. A total of 3169 TKAs performed between April 2003 and December 2013 were retrospectively reviewed. We determined the prevalence of malnutrition on applying different definitions, with various cutoff values of serum albumin and TLC and analyzed the variations in outcome. The differences between groups with and without malnutrition in terms of functional outcome and complications were determined using Student's t test and analysis of variance. Multivariate logistic regression analysis was conducted to identify the independent risk factors. Among all the patients (N = 3169), the serum albumin level and TLC varied widely, with means of 4.1 g/dL and 2189 cells/mm(3), respectively. The prevalence of malnutrition (21%) as per the conventional definition (serum albumin level malnutrition was defined as serum albumin malnutrition for predicting wound complications after TKA. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Disease-related malnutrition: influence on body composition and prognosis

    OpenAIRE

    Pirlich, Matthias

    2010-01-01

    Disease-related malnutrition is a frequent clincal problem with severe medical and economic impact. This work summarizes studies on body composition analysis, risk factors, prevalence and prognostic impact of malnutrition. The diagnosis of malnutrition in patients with chronic liver disease is hampered by hyperhydration and requires body composition analysis. Using four different methods for body composition analysis (total body potassium counting, anthropometry, bioelectrical impedance analy...

  15. Total and regional body-composition changes in early postmenopausal women

    DEFF Research Database (Denmark)

    Wang, Q; Hassager, C; Ravn, Pernille

    1994-01-01

    Total and regional body composition were measured in 373 early postmenopausal women aged 49-60 y by dual-energy x-ray absorptiometry to evaluate whether the changes in body composition in the early postmenopausal years are related to menopause itself or merely to age. Both fat mass and fat...

  16. In vivo measurement of total body carbon using 238Pu/Be neutron sources

    International Nuclear Information System (INIS)

    Sutcliffe, J.F.; Mitra, S.; Hill, G.L.

    1990-01-01

    Total body carbon has been measured by in vivo neutron activation analysis (IVNAA) in 278 surgical gastroenterological patients and 29 normal volunteers. This is based on the inelastic scattering reaction { 12 C(n,n') 12 C*} for neutrons with energy above 4.8MeV, producing 4.43 MeV gamma rays. Since only part of the body is scanned, total body carbon is estimated as the ratio of the gamma ray emission from carbon to the emission from hydrogen, using hydrogen as the internal standard. The precision of the estimate is ±1.6kg for a whole body dose of 0.3mSv. There is a significant difference between the estimates of total body water from IVNAA measurements of carbon and nitrogen and measurements of body water in these subjects by tritium dilution (t=3.1, p < 0.005). (author)

  17. Genetic relationships among linear type traits, milk yield, body weight, fertility and somatic cell count in primiparous dairy cows

    NARCIS (Netherlands)

    Berry, D.P.; Buckley, F.; Dillon, P.P.; Evans, R.D.; Veerkamp, R.F.

    2004-01-01

    Phenotypic and genetic (co)variances among type traits, milk yield, body weight, fertility and somatic cell count were estimated. The data analysed included 3,058 primiparous spring-calving Holstein-Friesian cows from 80 farms throughout the south of Ireland. Heritability estimates for the type

  18. Medical surveillance of nuclear power plant workers during reactor shutdown using whole-body counting and excretion analysis

    International Nuclear Information System (INIS)

    Le Roux-Desmis, C.

    1987-01-01

    After a review of radioactivity basis and radiation protection principles, the various aspects of medical surveillance of nuclear power plant workers during reactor shutdown, are presented. Internal contamination incidents that happened during 1986-1987 shutdown of Paluel reactor are exposed. Internal contamination levels are evaluated using whole-body counting and radionuclide determination in feces and urine and compared with dose limits [fr

  19. Body composition in acromegaly - before and after therapy

    International Nuclear Information System (INIS)

    Brummer, R.J.M.; Bengtsson, B.A.; Isaksson, B.

    1986-01-01

    Acromegaly is a disease caused by a benign pituitary tumor producing excess amount of growth hormone. A changed body composition can be a functional parameter of the disorder. The aim of this study is to describe body composition in acromegaly before and after therapy. Total body potassium (TBK) was measured as total exchangeable potassium using 42 K by dilution technique or by counting gamma radiation from the naturally present 40 K in a high sensitivity 3π whole body counter. Total body water (TBW) was determined with an isotope dilution technique using tritiated water as a tracer. The specific activity was measured in urine or plasma. The predicted values for TBK, TBW, and body fat (BF) were calculated by equations using body weight (BW), body height, age and sex as independent variables. The normal values for BW were calculated by using body height and sex as independent variables

  20. How do you define body image? Exploring conceptual gaps in understandings of body image at an exercise facility.

    Science.gov (United States)

    Bailey, K Alysse; Gammage, Kimberley L; van Ingen, Cathy

    2017-12-01

    The definition of body image has evolved within research; however, less is known about the layperson's understanding of the construct. This study explored how members and student trainees of an exercise facility (designed for older adults, people with physical disability, and those with cardiac complications) defined body image. Nineteen participants completed a one-on-one interview, and seven of those participants took part in six additional focus group meetings. The following main themes were found: stereotypical assumptions about body image (e.g., it is solely a person's weight or merely a woman's issue), body image continua for positive and negative body image, degree of complexity of body image dimensions, broad considerations of body image (e.g., it is self-esteem), and limited knowledge about body image. These findings suggest a need for knowledge translation between researchers and the general public which informs future body image program design. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tetsuo [Chiba Univ. (Japan). Inst. for Training Radiological Technicians; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-08-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m{sup 2}) and adjusted by age and sex of healthy persons. The R value was 100.65{+-}9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24{+-}11.22%, chronic hepatitis; 95.74{+-}11.24%, hyperthyroidism; 99.37{+-}10.8%, periodic paralysis; 82.0{+-}9.01%, Barter's syndrome; 93.99{+-}9.86%, myasthenia gravis; 97.34{+-}6.42% and hypo-potassemia; 90.64{+-}11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78{+-}11.5%, 99.22{+-}8.88%, 96.64{+-}12.73%, 98.5{+-}9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  2. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    International Nuclear Information System (INIS)

    Yamamoto, Tetsuo; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-01-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m 2 ) and adjusted by age and sex of healthy persons. The R value was 100.65±9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24±11.22%, chronic hepatitis; 95.74±11.24%, hyperthyroidism; 99.37±10.8%, periodic paralysis; 82.0±9.01%, Barter's syndrome; 93.99±9.86%, myasthenia gravis; 97.34±6.42% and hypo-potassemia; 90.64±11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78±11.5%, 99.22±8.88%, 96.64±12.73%, 98.5±9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  3. In vivo quantification of body nitrogen for nutritional assessment

    International Nuclear Information System (INIS)

    Cohn, S.H.; Vaswani, A.N.; Vartsky, D.; Yasumura, S.; Sawitsky, A.; Gartenhaus, W.; Ellis, K.J.

    1982-01-01

    A series of experimental tests were carried out to study total body nitrogen (TBN), total body potassium (TBK), total body water (TBW) and total body calcium (TBCa). The prompt neutron activation and whole body counting techniques were used to measure TBN and TBK, respectively. TBW was measured with the use of the standard tritiated water radioisotopic technique. Three groups of subjects were studied: normal controls, obese women on protein sparing diets, and cancer patients on chemotherapy. In relation to TBN, the obese patients showed a minimal negative nitrogen balance 0.49 to 0.87 g/day. With regard to the cancer patients, the data obtained in this study clearly corroborate the clinical observations. In patients with severe wasting, it is the skeletal muscle mass that is predominantly lost, not the visceral life-supporting system

  4. Measurement of total body radioactivity in man

    International Nuclear Information System (INIS)

    Naversten, Y.

    1982-01-01

    Techniques for the determination of whole-body radioactivity in man using uncollimated NaI(Tl) detectors have been studied. Geometrical effects and photon attenuation effects due to the different shapes of humans as well as due to varying in-vivo radioactivity distributions have been evaluated particularly for scanning-bed geometries and the chair geometry. Theoretically it is shown that the attenuation effects are generally dominating, for full-energy-peak pulse-range methods. For the application in radiation protection a cheap and simple chair-geometry unit has been constructed and used at various places distantly from the home-laboratory, for studies of body activity of Cs-137 in northern Sweden. High body activities were found particularly in reindeer-breeding Lapps. The elimination rate of Cs-137 in man was studied in the stationary whole-body counter in Lund as well as with the field-system. For the study of the performances at low and high photon energies clinical applications of methods for gastro-intestinal absorption of vitamin B12 (Co-57; 122 keV) and total body potassium determination (K-40; 1.46 MeV, K-42; 1.52 MeV) have been evaluated. Theoretical and experimental results as well as experiences of applications in radiation protection and medicine show that the scanning-bed geometry effectively evens out redistributional effects. For optimum results, however, scatter-energy pulse-ranges rather than full-energy-peak ranges should be used. (Auth.)

  5. Total Body Photography as an Aid to Skin Self-examination: A Patient's Perspective.

    Science.gov (United States)

    Secker, Lisanne J; Bergman, Wilma; Kukutsch, Nicole A

    2016-02-01

    Skin self-examination can help patients who are at high risk for developing melanoma to become more involved in their own surveillance and treatment. This study examined the use of total body photography as an aid to skin self-examination from the patients' perspective. A total of 179 individuals at high risk for developing melanoma who had undergone total body photography (60.5% response rate) completed a self-reported questionnaire assessing the frequency of skin self-examination, perceived usefulness of total body photography, and a variety of potential demographic, clinical and psychological factors. Only approximately half of the participants indicated skin self-examination as useful and 78.9% preferred clinical skin examination by a specialist. Finding total body photography useful was associated with having received instructions on how to perform skin self-examination, the use of a (hand)mirror, and confidence to detect changing moles. These findings allow us to develop strategies to further improve patients' self-screening behaviours.

  6. Counts-in-Cylinders in the Sloan Digital Sky Survey with Comparisons to N-Body

    Energy Technology Data Exchange (ETDEWEB)

    Berrier, Heather D.; Barton, Elizabeth J.; /UC, Irvine; Berrier, Joel C.; /Arkansas U.; Bullock, James S.; /UC, Irvine; Zentner, Andrew R.; /Pittsburgh U.; Wechsler, Risa H. /KIPAC, Menlo Park /SLAC

    2010-12-16

    Environmental statistics provide a necessary means of comparing the properties of galaxies in different environments and a vital test of models of galaxy formation within the prevailing, hierarchical cosmological model. We explore counts-in-cylinders, a common statistic defined as the number of companions of a particular galaxy found within a given projected radius and redshift interval. Galaxy distributions with the same two-point correlation functions do not necessarily have the same companion count distributions. We use this statistic to examine the environments of galaxies in the Sloan Digital Sky Survey, Data Release 4. We also make preliminary comparisons to four models for the spatial distributions of galaxies, based on N-body simulations, and data from SDSS DR4 to study the utility of the counts-in-cylinders statistic. There is a very large scatter between the number of companions a galaxy has and the mass of its parent dark matter halo and the halo occupation, limiting the utility of this statistic for certain kinds of environmental studies. We also show that prevalent, empirical models of galaxy clustering that match observed two- and three-point clustering statistics well fail to reproduce some aspects of the observed distribution of counts-in-cylinders on 1, 3 and 6-h{sup -1}Mpc scales. All models that we explore underpredict the fraction of galaxies with few or no companions in 3 and 6-h{sup -1} Mpc cylinders. Roughly 7% of galaxies in the real universe are significantly more isolated within a 6 h{sup -1} Mpc cylinder than the galaxies in any of the models we use. Simple, phenomenological models that map galaxies to dark matter halos fail to reproduce high-order clustering statistics in low-density environments.

  7. Hematologic status of mice submitted to sublethal total body irradiation with mixed neutron-gamma radiation

    International Nuclear Information System (INIS)

    Herodin, F.; Court, L.

    1989-01-01

    The hematologic status of mice exposed to sublethal whole body irradiation with mixed neutron-gamma radiation (mainly neutrons) is studied. A slight decrease of the blood cell count is still observed below 1 Gy. The recovery of bone marrow granulocyte-macrophage progenitors seems to require more time than after pure gamma irradiation [fr

  8. Osteochondroma after total body irradiation in bone marrow transplant recipients. Report of two cases

    International Nuclear Information System (INIS)

    Maeda, Go; Yokoyama, Ryohei; Ohtomo, Katsuyuki; Takayama, Jun; Beppu, Yasuo; Fukuma, Hisatoshi; Ohira, Mutsuro

    1996-01-01

    We present two cases of osteochondroma after total body irradiation in bone marrow recipients, the first in a 6-year-old boy with juvenile chronic myelogenous leukemia and the second in a 13-year-old boy with acute myelogenous leukemia. The patients developed multiple osteochondromas three years and seven years, respectively, after 12 Gy of total body irradiation. Neither had a family history of hereditary multiple osteochondromatosis. A review of the English literature revealed only one report describing five cases of osteochondroma after 12 Gy of total body irradiation in bone marrow transplant recipients. Osteochondroma should be considered as an additional adverse effect of total body irradiation. (author)

  9. Comparative Effectiveness of Two Walking Interventions on Participation, Step Counts, and Health.

    Science.gov (United States)

    Smith-McLallen, Aaron; Heller, Debbie; Vernisi, Kristin; Gulick, Diana; Cruz, Samantha; Snyder, Richard L

    2017-03-01

    To (1) compare the effects of two worksite-based walking interventions on employee participation rates; (2) compare average daily step counts between conditions, and; (3) examine the effects of increases in average daily step counts on biometric and psychologic outcomes. We conducted a cluster-randomized trial in which six employer groups were randomly selected and randomly assigned to condition. Four manufacturing worksites and two office-based worksite served as the setting. A total of 474 employees from six employer groups were included. A standard walking program was compared to an enhanced program that included incentives, feedback, competitive challenges, and monthly wellness workshops. Walking was measured by self-reported daily step counts. Survey measures and biometric screenings were administered at baseline and 3, 6, and 9 months after baseline. Analysis used linear mixed models with repeated measures. During 9 months, participants in the enhanced condition averaged 726 more steps per day compared with those in the standard condition (p women (-2.1 lbs.), and reductions in body mass index (-0.41 men, -0.31 women). Higher step counts were also associated with improvements in mood, having more energy, and higher ratings of overall health. An enhanced walking program significantly increases participation rates and daily step counts, which were associated with weight loss and reductions in body mass index.

  10. 137Cs exposure in the Marshallese populations: An assessment based on whole-body counting measurements (1989-1994)

    International Nuclear Information System (INIS)

    Sun, L.C.; Clinton, J.H.; Kaplan, E.

    1997-01-01

    The Marshall Islands were the site of numerous tests of nuclear weapons by the United States. From 1946 to 1958, nuclear devices were detonated at Enemetak and Bikini Atolls. Following the inadvertent contamination of the northern islands downwind of the 1954 Bravo Test, Brookhaven National Laboratory became involved in the medical care and the radiological safety of the affected populations. One important technique employed in assessing the internally deposited radionuclides is whole-body counting. To estimate current and future exposures to 1376, data from 1989 to 1994 were analyzed and are reported in this paper. During this period, 3,618 measurements were made for the Marshallese. The cesium body contents were assumed to result from a series of chronic intakes. Also, it was assumed that cesium activity in the body reaches a plateau that is maintained over 365 d. We estimated the annual effective dose rate for each population, derived from the recommendations of the International Commission on Radiological Protection. The average 137 Cs uptake measured by the whole-body counting method varies from one population to another; it was consistent with measurements of external exposure rate. The analysis. though based on limited data, indicates that there is no statistical support for a seasonal effect on 137 Cs uptake. The critical population group for cesium uptake is adult males. Within the 5-y monitoring period, all internal exposures to 137 Cs mere less than 0.2 mSv y -1 . Similarly, a persistent average cesium effective dose rate of 2 μSv y -1 was determined for Majuro residents. 73 refs., 6 figs., 10 tabs

  11. Total mesophilic counts underestimate in many cases the contamination levels of psychrotrophic lactic acid bacteria (LAB) in chilled-stored food products at the end of their shelf-life.

    Science.gov (United States)

    Pothakos, Vasileios; Samapundo, Simbarashe; Devlieghere, Frank

    2012-12-01

    The major objective of this study was to determine the role of psychrotrophic lactic acid bacteria (LAB) in spoilage-associated phenomena at the end of the shelf-life of 86 various packaged (air, vacuum, modified-atmosphere) chilled-stored retail food products. The current microbiological standards, which are largely based on the total viable mesophilic counts lack discriminatory capacity to detect psychrotrophic LAB. A comparison between the total viable counts on plates incubated at 30 °C (representing the mesophiles) and at 22 °C (indicating the psychrotrophs) for 86 food samples covering a wide range - ready-to-eat vegetable salads, fresh raw meat, cooked meat products and composite food - showed that a consistent underestimation of the microbial load occurs when the total aerobic mesophilic counts are used as a shelf-life parameter. In 38% of the samples, the psychrotrophic counts had significantly higher values (+0.5-3 log CFU/g) than the corresponding total aerobic mesophilic counts. A total of 154 lactic acid bacteria, which were unable to proliferate at 30 °C were isolated. In addition, a further 43 with a poor recovery at this temperature were also isolated. This study highlights the potential fallacy of the total aerobic mesophilic count as a reference shelf-life parameter for chilled food products as it can often underestimate the contamination levels at the end of the shelf-life. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Total body irradiation for children with malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Sanuki, Eiichi; Maeno, Toshio; Kamata, Rikisaburo; Tanaka, Yoshiaki; Mugishima, Hideo [Nihon Univ., Tokyo (Japan). School of Medicine

    1995-12-01

    Total body irradiation combined with high dose chemotherapy has been performed just before bone marrow transplantation in 35 children with advanced malignancies, with the object of achieving successful transplantation and improving the prognosis. Simulation was performed as follows: back scatter, flatness, dose accumulation using randophantom and dose distribution using a thermo-luminescence dosimeter and linac-graphy. The standard error of dose distribution was within 10%. In neuroblastoma, of which there were 14 cases in stage IV and one case in stage III, the 5-year survival rate was 55%. In leukemia, of which all cases were in the high-risk group (7 cases of acute lymphoblastic leukemia and 2 of acute myeloblastic leukemia) the 5-year survival rate was 55%. The 5 cases having first remission survived disease-free while the 4 cases having non-first remission died. In malignant lymphoma (6 cases in stage IV and one case in stage III, with bulky mass) the 5-year survival rate was 67%. Four cases with other diagnoses (severe aplastic anemia, and others) all survived. As yet no side effects resulting from total body irradiation have been recognized in our cases, but a longer follow-up period is necessary to observe possible late side effects. (author).

  13. Automated facility for analysis of soil samples by neutron activation, counting, and data control

    International Nuclear Information System (INIS)

    Voegele, A.L.; Jesse, R.H.; Russell, W.L.; Baker, J.

    1978-01-01

    An automated facility remotely and automatically analyzes soil, water, and sediment samples for uranium. The samples travel through pneumatic tubes and switches to be first irradiated by neutrons and then counted for resulting neutron and gamma emission. Samples are loaded into special carriers, or rabbits, which are then automatically loaded into the pneumatic transfer system. The sample carriers have been previously coded with an identification number, which can be automatically read in the system. This number is used for correlating and filing data about the samples. The transfer system, counters, and identification system are controlled by a network of microprocessors. A master microprocessor initiates routines in other microprocessors assigned to specific tasks. The software in the microprocessors is unique for this type of application and lends flexibility to the system

  14. Land-based whole-body counting on Enewetak Island in the Marshall Islands for 137Cs

    International Nuclear Information System (INIS)

    Barss, N.M.; Bell, R.T.; Sun, L.C.; Clinton, J.H.; Kaplan, E.

    1996-01-01

    The U.S. Department of Energy (DOE) contracts Brookhaven National Laboratory- (BNL) scientists to perform a whole-body counting (WBC) program of the people living at Enewetak Island since 1980. Goals of the program are to monitor the intake of fission products and to assure the radiation safety of the residing population. Under the current direction of the DOE Office of International Health Programs, a WBC unit has been transported and installed at the Enewetak Field Station during a mission from 27 November to 11 December 1995. Previous WBC missions had been conducted aboard a vessel provided by DOE. The main objective of this land-based approach is to provide a self-monitoring capability for the Enewetakese in any season at any time. The purposes of this paper are to (1) describe the technical basis for this land-based WBC operation, (2) report current monitoring results, and (3) compare the average cesium dose rates from this mission with previous WBC results. The minimum detectable amount (MDA) of the WBC system is about 60 Bq in a 900 s interval. Due to local life style in a tropical environment, about 20 counting measurements can be made per day. The average cesium body content measured during this mission is 307±218 Bq for male adults, which is the lowest value since 1980. Assuming a continuous steady state intake of cesium, the corresponding effective dose rate from 137 Cs is about 11 μSv y -1

  15. Observations on total-body calcium in humans with bone disease

    International Nuclear Information System (INIS)

    Spinks, T.J.; Bewley, D.K.; Ranicar, A.S.O.; Joplin, G.F.; Evans, I.M.A.; Vlotides, J.; Paolillo, M.

    1979-01-01

    Total-body calcium was measured in-vivo by neutron activation in a number of patients suffering from metabolic abnormalities which affect the skeleton. In general, less than 2% of total calcium resides in tissue other than bone allowing calcium mass to be directly related to skeletal mass. The conditions studied were (i) Paget's disease, treated with synthetic human calcitonin, (ii) osteoporosis, treated variously with calcium and phosphate supplements and 1,25 hydroxycholecalciferol, and (iii) Cushing's disease treated by pituitary implant of 198 Au or 90 Y seeds. The neutron beam used in these studies was produced by bombarding a beryllium target with deuterons accelerated in a cyclotron. The mean neutron energy was 7.5 MeV and patients received a total dose of 1 rem in about 30 s, a bilateral irradiation being employed. Measurements were made at approximately yearly intervals, the maximum period of study being about four and a half years. The precision of the method was estimated to be +-3% (SE) and a correction was applied for changes in body weight. In most patients, total calcium remained stable. However, in the Paget's patients, there was an indication of a slow upward trend while the osteoporotics (both treated and untreated) showed on average no change. Most of the patients with Cushing's disease showed no recovery of skeletal mass. Absolute calibration indicated that mean total body calcium in the Paget's patients was close to a predicted normal while that for the osteoporotic and Cushing's patients was 20-25% below this. (author)

  16. Improved models for determination of body fat by in vivo neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.; Vaswani, A.; Yasumura, S.; Yuen, K.; Ellis, K.

    1984-01-01

    In the present study, two different models of body composition, based on data obtained by nuclear techniques are used. Total body nitrogen, calcium, and chlorine were obtained by total body neutron activation. Total body chlorine was used to estimate extracellular water, and total body calcium to determine bone mineral and extracellular solids. Total body potassium was measured by whole body counting to obtain the body cell mass. In addition, total body water was measured by the tritium dilution technique. It was found that either model can be used equally well to measure total body fat in normal subjects. Estimation of body fat as the difference between body weight and the sum of total body nitrogen (protein), total body water, and bone ash (model 1) appears to have an advantage over model 2, which uses body cell mass, extracellular water, and extracellular solids, particularly for patients with metabolic disorders. This advantage is partly due to the fact that the parameter protein (total body nitrogen) is less affected in metabolic disorders than the more labile total body potassium. The closely correlated results obtained with the two models based on nuclear measurements support the conclusion that these techniques provide reliable measurements of total body fat

  17. Effect of aflatoxin ingestion on total body water (T OH3 - space), total body solids A KD on some physiological and reproductive characteristics of male albino rats

    International Nuclear Information System (INIS)

    Nowar, M.S.; Eldarawany, A.A.; Habeeb, A.A.

    1992-01-01

    This investigation aimed to study the effects of aflatoxins B 1 +G 1 mixture mainly on total body water (TBW) and on total body solids (TBS) of male albino rats. Some blood components and some reproductive characteristic were also taken into consideration. Two groups, each of 8 male rats were fed the same ration. Rats of one group had been individually ingested daily with a dose of 22 μg B 1 plus 22 μg G 1 for 15 successive weeks. The obtained results showed that aflatoxin administration caused: 1- A decrease in final body weight (FBW), TBW (P<0.01) and TBS (P<0.05). 2- A decrease in serum total proteins (P<0.01), albumin (P<0.05), globulin (P<0.05), glucose (P<0.05) and increase in serum cholesterol, GOT and GPT (P<0.05) activities. 3- A decrease in each of the number of effective matings of males and delivery percentages of females mated with treated males.1 tab

  18. NASA Construction of Facilities Validation Processes - Total Building Commissioning (TBCx)

    Science.gov (United States)

    Hoover, Jay C.

    2004-01-01

    Key Atributes include: Total Quality Management (TQM) System that looks at all phases of a project. A team process that spans boundaries. A Commissioning Authority to lead the process. Commissioning requirements in contracts. Independent design review to verify compliance with Facility Project Requirements (FPR). Formal written Commissioning Plan with Documented Results. Functional performance testing (FPT) against the requirements document.

  19. Long-Term Effects of Stem Cells on Total-Body Irradiated Mice

    Science.gov (United States)

    Vyalkina, M. V.; Alchinova, I. B.; Yakovenko, E. N.; Medvedeva, Yu S.; Saburina, I. N.; Karganov, M. Yu

    2017-01-01

    C57Bl/6 mice were exposed to γ-radiation in a sublethal dose of 7.5 Gy. In 3 hours injection 106/mouse of bone marrow multipotent mesenchymal stromal cells stem cells intravenously to experimental group was done. Methods used: body weight measurement, open field behavior, subfraction composition of blood serum (laser correlation spectroscopy, LCS), histological examination of the spleen, liver, and pancreas, count of T and B cells, white blood formula. After 1.5 and 3 months the general trend towards intermediate position of the parameters observed in the experimental between those in intact and irradiated controls attests to partial protective/restorative effects of the injected cells.

  20. Long-Term Effects of Stem Cells on Total-Body Irradiated Mice

    International Nuclear Information System (INIS)

    Vyalkina, M V; Alchinova, I B; Yakovenko, E N; Medvedeva, Yu S; Saburina, I N; Karganov, M Yu

    2017-01-01

    C57Bl/6 mice were exposed to γ-radiation in a sublethal dose of 7.5 Gy. In 3 hours injection 10 6 /mouse of bone marrow multipotent mesenchymal stromal cells stem cells intravenously to experimental group was done. Methods used: body weight measurement, open field behavior, subfraction composition of blood serum (laser correlation spectroscopy, LCS), histological examination of the spleen, liver, and pancreas, count of T and B cells, white blood formula. After 1.5 and 3 months the general trend towards intermediate position of the parameters observed in the experimental between those in intact and irradiated controls attests to partial protective/restorative effects of the injected cells. (paper)

  1. Correlation of total body potassium and leukemic cell mass in patients with chronic lymphocytic leukemia

    International Nuclear Information System (INIS)

    Chandra, P.; Sawitsky, A.; Chanana, A.D.; Chikkappa, G.; Cohn, S.H.; Rai, K.R.; Cronkity, E.P.

    1979-01-01

    Total body leukemic mass in patients with chronic lymphocytic leukemia (CLL) was measured by quantitation of total body potassium (TBK) with a whole-body counter. In addition, the predicted normal total body potassium (Kp) for each patient was calculated from an empirically derived relationship involving height, weight age, and sex. Both the absolute TBK and the relative excess of total body potassium (TBK/Kp) were related to the stage of disease. Patients in the early stages of CLL were found to have lower TBK and TBK/Kp than patients in the late stages of disease. Both of these parameters increased with the successively advanced stages of the disease. The clinically monitored reduction of leukemic cell mass following therapy was accompanied by reductions in TBK and TBK/Kp. Data presented support the notion that TBK/Kp is a useful indicator of the total body leukemic mass. Futhermore, the results of these studies quantitatively validate the proposed clinical staging system for CLL. Quantitation of TBK by a whole-body counter is an accurate and noninvasive procedure and does not require administration of isotopes

  2. From Talking Heads to Communicating Bodies: Cybersemiotics and Total Communication

    Directory of Open Access Journals (Sweden)

    Ole Nedergaard Thomsen

    2010-03-01

    Full Text Available Current linguistics is biased towards considering as object of scientific study only verbal language, i.e., ordinary language whose basic entities are words, sentences, and texts. By having this focus, the crucial non-verbal semiotic contributions from acts of bodily communication are left out of consideration. On the face of it, this is a strange situation, because, phenomenologically, when observing a communicating dyad, what appears to the senses is a multimodal semiotic display–the interactants produce acts of total communication, the linguistic part of which has in fact to be disentangled from the integral semiotic behavior. That a human being should in the first place be conceptualized as a ‘talking head’, rather than a ‘communicating body’, stems from at least four historically interrelated fountains: ancient Greek philosophy with its emphasis on logos as meaning both rational mind and verbal language/speech as well as with its rejection of rhetoric (including body language; Cartesian dualistic rationalism where the body was the animal, mechanistic part of a human being, unworthy for the Geisteswissenschaften; Saussure’s formal structuralism with its defocusing of the individual’s performance, parole, and its high focus on societal langue; and Chomskyan linguistics with its neglect of actual, also bodily, performance, and its total focus on an ideal mental grammatical computational competence. With the recent philosophy (‘in the flesh’ of the ‘embodied mind’, time has now come for integrating the (linguistic head with the (other part of the communicating body and seeing communication as total communication of the whole body. This means that the communicating mind is no longer restricted to its ‘rational’ aspects but has to be conceived full-scale as integrating also all kinds of ‘irrational’ factors, like emotions and motivations. Another, no less important, implication of the above is that an individual

  3. Review and assessment of nuclear facilities by the regulatory body. Safety guide

    International Nuclear Information System (INIS)

    2004-01-01

    The purpose of this Safety Guide is to provide recommendations for regulatory bodies on reviewing and assessing the various safety related submissions made by the operator of a nuclear facility at different stages (siting, design, construction, commissioning, operation and decommissioning or closure) in the facility's lifetime to determine whether the facility complies with the applicable safety objectives and requirements. This Safety Guide covers the review and assessment of submissions in relation to the safety of nuclear facilities such as: enrichment and fuel manufacturing plants. Nuclear power plants. Other reactors such as research reactors and critical assemblies. Spent fuel reprocessing plants. And facilities for radioactive waste management, such as treatment, storage and disposal facilities. This Safety Guide also covers issues relating to the decommissioning of nuclear facilities, the closure of waste disposal facilities and site rehabilitation. Objectives, management, planning and organizational matters relating to the review and assessment process are presented in Section 2. Section 3 deals with the bases for decision making and conduct of the review and assessment process. Section 4 covers aspects relating to the assessment of this process. The Appendix provides a generic list of topics to be covered in the review and assessment process

  4. Review and assessment of nuclear facilities by the regulatory body. Safety guide

    International Nuclear Information System (INIS)

    2005-01-01

    The purpose of this Safety Guide is to provide recommendations for regulatory bodies on reviewing and assessing the various safety related submissions made by the operator of a nuclear facility at different stages (siting, design, construction, commissioning, operation and decommissioning or closure) in the facility's lifetime to determine whether the facility complies with the applicable safety objectives and requirements. This Safety Guide covers the review and assessment of submissions in relation to the safety of nuclear facilities such as: enrichment and fuel manufacturing plants. Nuclear power plants. Other reactors such as research reactors and critical assemblies. Spent fuel reprocessing plants. And facilities for radioactive waste management, such as treatment, storage and disposal facilities. This Safety Guide also covers issues relating to the decommissioning of nuclear facilities, the closure of waste disposal facilities and site rehabilitation. Objectives, management, planning and organizational matters relating to the review and assessment process are presented in Section 2. Section 3 deals with the bases for decision making and conduct of the review and assessment process. Section 4 covers aspects relating to the assessment of this process. The Appendix provides a generic list of topics to be covered in the review and assessment process

  5. A comparative study of total body irradiation as a method of inducing granulocyte depletion in mice

    International Nuclear Information System (INIS)

    Bogman, M.J.J.T.; Cornelissen, I.M.H.A.; Berden, J.H.M.; Jong, J. de; Koene, R.A.P.

    1984-01-01

    Since conventional methods of inducing depletion of polymorphonuclear granulocytes (PMNs) in mice, such as treatment with cytostatic drugs and anti-PMN sera, proved to be insufficient to induce a stable PMN depletion for several days, and were accompanied by considerable toxic side effects, we induced neutrophil depletion in mice by total body irradiation (TBI) in a single dose of 6.0 Gy (600 rads.) at a dose rate of 0.20 Gy/min. This treatment reduced the number of PMNs in the peripheral circulation to values below 150/μl from day 3-10 after irradiation. The number of lymphocytes fell simultaneously. Platelet counts remained above 60% of normal values during the first 7 days after irradiation. Complement levels were not significantly affected by TBI. The results show that TBI of 6.0 Gy induces pronounced and stable PMN depletion in mice for at least 7 days. Furthermore, under an aseptic regimen the mice can be kept in good condition and losses are less than 5%. (Auth.)

  6. Fractionated homogenous total-body irradiation prior to bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Duehmke, E; Brix, F; Hebbinghaus, D; Jensen, M; Wendhausen, H; Schmitz, N

    1985-03-01

    At the University of Kiel, myeloid and acute lymphatic leukemia is treated since 1983 by total-body irradiation applied prior to bone marrow transplantation. Dose deviations in the midplane caused by the irregular surface and tissue inhomogeneities of the patient are reduced down to +-3.5% compared to the central ray, with the help of CT-based individual compensators. This method prevents above all an excessive dose to the lungs. The radiobiologic advantages of fractionated irradiation have been employed for all patients treated hitherto (n = 9). At present, a total body dose of 12 Gy in six fractions is applied within three days. There were no undesired acute radiogenic reactions except a mild acute mucositis found in all patients. Chronic side effects, especially in the lungs, were not demonstrated, too. However, the average follow-up time of 149 days has been rather short. One patient died from relapse of leukemia after a total dose of 10 Gy, another patient died because the transplanted bone marrow was rejected, and a third died from catheter sepsis. Six out of nine patients are in complete remission with a maximum index of Karnofsky. The limited experiences gained hitherto show that the homogeneous accelerated-fractionated total-body irradiation offers essential advantages compared to non-compensated single dose irradiation with respect to the prevention of undesired radiogenic effects in sound tissues and that its therapeutic efficacy is at least the same.

  7. Counting radon tracks in Makrofol detectors with the 'image reduction and analysis facility' (IRAF) software package

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, F. [Laboratorio de Fisica Medica y Radioactividad Ambiental, Departamento de Medicina Fisica y Farmacologia, Universidad de La Laguna, 38320 La Laguna, Tenerife (Spain)]. E-mail: fimerall@ull.es; Gonzalez-Manrique, S. [Laboratorio de Fisica Medica y Radioactividad Ambiental, Departamento de Medicina Fisica y Farmacologia, Universidad de La Laguna, 38320 La Laguna, Tenerife (Spain); Karlsson, L. [Laboratorio de Fisica Medica y Radioactividad Ambiental, Departamento de Medicina Fisica y Farmacologia, Universidad de La Laguna, 38320 La Laguna, Tenerife (Spain); Hernandez-Armas, J. [Laboratorio de Fisica Medica y Radioactividad Ambiental, Departamento de Medicina Fisica y Farmacologia, Universidad de La Laguna, 38320 La Laguna, Tenerife (Spain); Aparicio, A. [Instituto de Astrofisica de Canarias, 38200 La Laguna, Tenerife (Spain); Departamento de Astrofisica, Universidad de La Laguna. Avenida. Astrofisico Francisco Sanchez s/n, 38071 La Laguna, Tenerife (Spain)

    2007-03-15

    Makrofol detectors are commonly used for long-term radon ({sup 222}Rn) measurements in houses, schools and workplaces. The use of this type of passive detectors for the determination of radon concentrations requires the counting of the nuclear tracks produced by alpha particles on the detecting material. The 'image reduction and analysis facility' (IRAF) software package is a piece of software commonly used in astronomical applications. It allows detailed counting and mapping of sky sections where stars are grouped very closely, even forming clusters. In order to count the nuclear tracks in our Makrofol radon detectors, we have developed an inter-disciplinary application that takes advantage of the similitude that exist between counting stars in a dark sky and tracks in a track-etch detector. Thus, a low cost semi-automatic system has been set up in our laboratory which utilises a commercially available desktop scanner and the IRAF software package. A detailed description of the proposed semi-automatic method and its performance, in comparison to ocular counting, is described in detail here. In addition, the calibration factor for this procedure, 2.97+/-0.07kBqm{sup -3}htrack{sup -1}cm{sup 2}, has been calculated based on the results obtained from exposing 46 detectors to certified radon concentrations. Furthermore, the results of a preliminary radon survey carried out in 62 schools in Tenerife island (Spain), using Makrofol detectors, counted with the mentioned procedure, are briefly presented. The results reported here indicate that the developed procedure permits a fast, accurate and unbiased determination of the radon tracks in a large number of detectors. The measurements carried out in the schools showed that the radon concentrations in at least 12 schools were above 200Bqm{sup -3} and, in two of them, above 400Bqm{sup -3}. Further studies should be performed at those schools following the European Union recommendations about radon concentrations in

  8. Total body photography for skin cancer screening.

    Science.gov (United States)

    Dengel, Lynn T; Petroni, Gina R; Judge, Joshua; Chen, David; Acton, Scott T; Schroen, Anneke T; Slingluff, Craig L

    2015-11-01

    Total body photography may aid in melanoma screening but is not widely applied due to time and cost. We hypothesized that a near-simultaneous automated skin photo-acquisition system would be acceptable to patients and could rapidly obtain total body images that enable visualization of pigmented skin lesions. From February to May 2009, a study of 20 volunteers was performed at the University of Virginia to test a prototype 16-camera imaging booth built by the research team and to guide development of special purpose software. For each participant, images were obtained before and after marking 10 lesions (five "easy" and five "difficult"), and images were evaluated to estimate visualization rates. Imaging logistical challenges were scored by the operator, and participant opinion was assessed by questionnaire. Average time for image capture was three minutes (range 2-5). All 55 "easy" lesions were visualized (sensitivity 100%, 90% CI 95-100%), and 54/55 "difficult" lesions were visualized (sensitivity 98%, 90% CI 92-100%). Operators and patients graded the imaging process favorably, with challenges identified regarding lighting and positioning. Rapid-acquisition automated skin photography is feasible with a low-cost system, with excellent lesion visualization and participant acceptance. These data provide a basis for employing this method in clinical melanoma screening. © 2014 The International Society of Dermatology.

  9. Increase of Total Body Water with Decrease of Body Mass while Running 100 km Nonstop--Formation of Edema?

    Science.gov (United States)

    Knechtle, Beat; Wirth, Andrea; Knechtle, Patrizia; Rosemann, Thomas

    2009-01-01

    We investigated whether ultraendurance runners in a 100-km run suffer a decrease of body mass and whether this loss consists of fat mass, skeletal muscle mass, or total body water. Male ultrarunners were measured pre- and postrace to determine body mass, fat mass, and skeletal muscle mass by using the anthropometric method. In addition,…

  10. NIF total neutron yield diagnostic

    International Nuclear Information System (INIS)

    Cooper, Gary W.; Ruiz, Carlos L.

    2001-01-01

    We have designed a total neutron yield diagnostic for the National Ignition Facility (NIF) which is based on the activation of In and Cu samples. The particular approach that we have chosen is one in which we calibrate the entire counting system and which we call the ''F factor'' method. In this method, In and/or Cu samples are exposed to known sources of DD and DT neutrons. The activated samples are then counted with an appropriate system: a high purity Ge detector for In and a NaI coincidence system for Cu. We can then calculate a calibration factor, which relates measured activity to total neutron yield. The advantage of this approach is that specific knowledge of such quantities as cross sections and detector efficiencies is not needed. Unless the actual scattering environment of the NIF can be mocked up in the calibration experiment, the F factor will have to be modified using the results of a numerical simulation of the NIF scattering environment. In this article, the calibration factor methodology will be discussed and experimental results for the calibration factors will be presented. Total NIF neutron yields of 10 9 --10 19 can be measured with this method assuming a 50 cm stand-off distance can be employed for the lower yields

  11. Total white blood cell counts and LPS-induced TNF alpha production by monocytes of pregnant, pseudopregnant and cyclic rats

    NARCIS (Netherlands)

    Faas, MM; Moes, H; van der Schaaf, G; de Leij, LFMH; Heineman, MJ

    Pregnancy in the rat may be associated with an activated innate immune system. Therefore, we investigated monocyte function as well as total white blood cell (WBC) counts during the follicular phase of the ovarian cycle, pregnancy and pseudopregnancy in the rat. Rats were equipped with a permanent

  12. Total white blood cell counts and LPS-induced TNF alpha production by monocytes of pregnant, pseudopregnant and cyclic rats

    NARCIS (Netherlands)

    Faas, M. M.; Moes, H.; van der Schaaf, G.; de Leij, L. F. M. H.; Heineman, M. J.

    2003-01-01

    Pregnancy in the rat may be associated with an activated innate immune system. Therefore, we investigated monocyte function as well as total white blood cell (WBC) counts during the follicular phase of the ovarian cycle, pregnancy and pseudopregnancy in the rat. Rats were equipped with a permanent

  13. Nutritional education and carbohydrate counting in children with type 1 diabetes treated with continuous subcutaneous insulin infusion: the effects on dietary habits, body composition and glycometabolic control.

    Science.gov (United States)

    Marigliano, Marco; Morandi, Anita; Maschio, Maddalena; Sabbion, Alberto; Contreas, Giovanna; Tomasselli, Francesca; Tommasi, Mara; Maffeis, Claudio

    2013-12-01

    Carbohydrate counting (CHC) in combination with nutritional education has been used to optimize the insulin dose in patients with type 1 diabetes (T1D). The aim of this study was to test the impact of CHC and nutritional education on changes in dietary habits, body composition and body fat distribution in children with T1D treated with insulin pumps (CSII). Twenty-five children with T1D and CSII were recruited and valuated at baseline and after 18 months of follow-up. They were trained in CHC and following standard nutrition education program (based on American Diabetes Association and International Society of Pediatric and Adolescent Diabetes guidelines); clinical, biochemical and nutritional variables were measured. In the total population, body composition, body fat distribution and biochemical variables did not change, at follow-up; HbA1c was significantly reduced (8.50 ± 0.77 vs 7.92 ± 0.74 %; p nutritional education, does not affect dietary habits, body composition and body fat distribution in children with T1D treated with CSII. Moreover, the sub-group of subjects showing a significant improvement in glycometabolic control reported an increase in CHO intake and a reduction in fat and protein intake.

  14. Radiation Counting System Software Using Visual Basic

    International Nuclear Information System (INIS)

    Nanda Nagara; Didi Gayani

    2009-01-01

    It has been created a Gamma Radiation Counting System using interface card, which paired with Personal Computer (PC) and operated by the Visual Basic program. The program was set through varied menu selections such as ”Multi Counting” , ”Counting and Record” and ”View Data”. An interface card for data acquisition was formed by using AMD9513 components as a counter and timer which can be programmed. This counting system was tested and used in waste facility in PTNBR and the result is quite good. (author)

  15. Measuring radioactivity in the body

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1961-09-15

    Techniques of measuring the total amount of radioactivity in the body of a living person as well as the principal applications of such measurements were reviewed at a Symposium on Whole Body Counting held in Vienna from 12 to 16 June 1961. The whole body counters can be divided into two broad groups: (a) counters for the radiation protection surveillance of the general public and radiation workers, capable of detecting extremely low levels of radioactivity in the human body, and (b) counters for medical research and diagnosis, designed to check the retention and excretion of radioactive substances administered to patients for metabolic and pathological studies. In both cases, the primary requirement is that the counter must be able to measure the total activity in the body. In recent years, there has been a remarkable development of the instruments and techniques for such measurements. One of the main purposes of the symposium in Vienna was to discuss how best to use these highly sophisticated instruments.

  16. COUNTS-IN-CYLINDERS IN THE SLOAN DIGITAL SKY SURVEY WITH COMPARISONS TO N-BODY SIMULATIONS

    International Nuclear Information System (INIS)

    Berrier, Heather D.; Barton, Elizabeth J.; Bullock, James S.; Berrier, Joel C.; Zentner, Andrew R.; Wechsler, Risa H.

    2011-01-01

    Environmental statistics provide a necessary means of comparing the properties of galaxies in different environments, and a vital test of models of galaxy formation within the prevailing hierarchical cosmological model. We explore counts-in-cylinders, a common statistic defined as the number of companions of a particular galaxy found within a given projected radius and redshift interval. Galaxy distributions with the same two-point correlation functions do not necessarily have the same companion count distributions. We use this statistic to examine the environments of galaxies in the Sloan Digital Sky Survey Data Release 4 (SDSS DR4). We also make preliminary comparisons to four models for the spatial distributions of galaxies, based on N-body simulations and data from SDSS DR4, to study the utility of the counts-in-cylinders statistic. There is a very large scatter between the number of companions a galaxy has and the mass of its parent dark matter halo and the halo occupation, limiting the utility of this statistic for certain kinds of environmental studies. We also show that prevalent empirical models of galaxy clustering, that match observed two- and three-point clustering statistics well, fail to reproduce some aspects of the observed distribution of counts-in-cylinders on 1, 3, and 6 h -1 Mpc scales. All models that we explore underpredict the fraction of galaxies with few or no companions in 3 and 6 h -1 Mpc cylinders. Roughly 7% of galaxies in the real universe are significantly more isolated within a 6 h -1 Mpc cylinder than the galaxies in any of the models we use. Simple phenomenological models that map galaxies to dark matter halos fail to reproduce high-order clustering statistics in low-density environments.

  17. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

    Science.gov (United States)

    Yu, Zhicong; Leng, Shuai; Jorgensen, Steven M; Li, Zhoubo; Gutjahr, Ralf; Chen, Baiyu; Halaweish, Ahmed F; Kappler, Steffen; Yu, Lifeng; Ritman, Erik L; McCollough, Cynthia H

    2016-02-21

    This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x

  18. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array

    International Nuclear Information System (INIS)

    Yu, Zhicong; Leng, Shuai; Li, Zhoubo; Chen, Baiyu; Yu, Lifeng; McCollough, Cynthia H; Jorgensen, Steven M; Ritman, Erik L; Gutjahr, Ralf; Kappler, Steffen; Halaweish, Ahmed F

    2016-01-01

    This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x

  19. Measurement of total-body oxygen, nitrogen, and carbon in vivo by photon activation analysis

    International Nuclear Information System (INIS)

    Ulin, K.

    1984-01-01

    With the aim of assessing nutritional status, the feasibility of measuring the total body quantities of the major body elements, i.e. oxygen, nitrogen, and carbon, using the photon beam of a 45 MV betatron and a whole-body counter, has been evaluated in detail. Following photon activation a single energy γ-radiation (.511 MeV) is observed from all three elements to be measured. The half-lives of 15 O, 13 N, and 11 C, however, are sufficiently different (20.5 min, 10.0 min, and 20.4 min. respectively) to permit their measurement from an analysis of the measured decay curve. Following corrections for interfering reactions, a computer curve-fitting algorithm is used to resolve the data into 15 O, 13 N, and 11 C components. Measurements of O, N, and C have been made both in phantoms and in live and dead rats. A comparison of the body composition results from this technique with results from chemical analysis indicates that measured carbon can quite accurately predict total body fat. The comparison of the total body nitrogen measurement by photon activation with total body protein by chemical analysis was inconclusive and suggests that further work be done to verify the estimated accuracy of the nitrogen measurement

  20. Evaluation of the performance of a point-of-care method for total and differential white blood cell count in clozapine users.

    Science.gov (United States)

    Bui, H N; Bogers, J P A M; Cohen, D; Njo, T; Herruer, M H

    2016-12-01

    We evaluated the performance of the HemoCue WBC DIFF, a point-of-care device for total and differential white cell count, primarily to test its suitability for the mandatory white blood cell monitoring in clozapine use. Leukocyte count and 5-part differentiation was performed by the point-of-care device and by routine laboratory method in venous EDTA-blood samples from 20 clozapine users, 20 neutropenic patients, and 20 healthy volunteers. From the volunteers, also a capillary sample was drawn. Intra-assay reproducibility and drop-to-drop variation were tested. The correlation between both methods in venous samples was r > 0.95 for leukocyte, neutrophil, and lymphocyte counts. The correlation between point-of-care (capillary sample) and routine (venous sample) methods for these cells was 0.772; 0.817 and 0.798, respectively. Only for leukocyte and neutrophil counts, the intra-assay reproducibility was sufficient. The point-of-care device can be used to screen for leukocyte and neutrophil counts. Because of the relatively high measurement uncertainty and poor correlation with venous samples, we recommend to repeat the measurement with a venous sample if cell counts are in the lower reference range. In case of clozapine therapy, neutropenia can probably be excluded if high neutrophil counts are found and patients can continue their therapy. © 2016 John Wiley & Sons Ltd.

  1. Biochemical and hematological indicators in model of total body irradiation; Indicadores bioquimicos y hematologicos en un modelo de irradiacion corporal total

    Energy Technology Data Exchange (ETDEWEB)

    Dubner, D; Gisone, P; Perez, M R [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina); Barboza, M [Hospital de Clinicas Jose de San Martin, Buenos Aires (Argentina); Luchetta, P; Longoni, H; Sorrentino, M; Robison, A [Hospital Naval Pedro Mallo, Buenos Aires (Argentina)

    1998-07-01

    With the purpose of evaluating the applicability of several biological indicators in accidental overexposures a study was carried out in 20 patients undergoing therapeutical total body irradiation (TBI). The following parameters were evaluated: a) Oxidative stress indicators: erythrocyte superoxide dismutase (SOD) and catalase activity (CAT), lipo peroxyde levels (TBARS) and total plasma antioxidant activity (TAA). b) Haematological indicators: reticulocyte maturity index (RMI) and charges in lymphocyte subpopulations. Non significant changes in SOD and CAT activity were observed. Significant higher TBARS levels were found in patients with unfavorable post-BTM course without any significant correlation with TAA. RMI decreased early and dropped to zero in most of the patients and rose several days prior to reticulocyte, neutrophils and platelets counts. A significant decrease in absolute counts of all lymphocyte subpopulations was observed during TBI, particularly for B lymphocytes. A subpopulation of natural killer (NK) cells (CD16+/ CD 56 +) showed a relative higher radioresistance. Cytotoxic activity was significantly decreased after TBI. These data suggest that TBARS could provide an useful evolutive indicator in accidental over exposure d patients and RMI is an early indicator of bone marrow recovery after radioinduced aplasia. The implications of the different radiosensitivities within the NK subsets remains unanswered. (author) [Spanish] Se presentan los resultados de un estudio multiparametrico realizado en pacientes sometidos a irradiacion corporal total (ICT) a fin de evaluar al aplicabilidad de ciertos indicadores bioquimicos y hematologicos en personas accidentalmente sobreexpuestas a radiaciones ionizantes. El trabajo se realizo en pacientes incluidos en un protocolo de irradiacion terapeutica (12 Gy / 4 dias) previo a un transplante de medula osea (TMO). Se tomaron muestras secuenciales de sangre periferica hasta el alta del paciente. Se evaluaron: a

  2. Risk management in radiotherapy: analysis for total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Banguero, Y., E-mail: ybanguero@cin.edu.uy [Universidad de la República, Montevideo (Uruguay); Píriz, G.; Guerrero, L.; Cardozo, L.; Quarneti, A. [Centro Hospital Pereira Rossell, Montevideo (Uruguay); Nader, A. [Autoridad Reguladora Nacional de Radioprotección, Montevideo (Uruguay)

    2017-07-01

    Introduction: Management of risk in any technique that is using radiation energy is very important to prevent incidents and accidents. Pretending evaluate the risk in the all process of Total Body Irradiation (TBI), this work present a risk matrix with different possible events than could occur. Methods: SEVRRA-R platform that run in windows is using to build a risk matrix separating the process of TBI in commissioning, prescription, planning and delivering dose. Any stage has a procedure with different errors associated. We build a matrix using all this information to evaluate the kind of risk we have in the technique. Results: It was obtained a template that describes in general the process of TBI with principles events, barriers and consequences. Conclusion: Analyzing the risk in any stage of the process in Total Body irradiation is a useful tool to understand the key points to work in safety for this technique. (author)

  3. Calibration Human Voxel Phantoms for In Vivo Measurement of ''241 Am in Bone at the Whole Body Counter Facility of CIEMAT

    International Nuclear Information System (INIS)

    Moraleda, M.; Lopez, M. A.; Gomez Ros, J. M.; Navarro, T.; Navarro, J. F.

    2002-01-01

    The Whole Body Counting facility of CIEMAT is capable of carrying out In-Vivo measurements of radionuclides emitting X-rays and low energy gamma radiation internally deposited in the body. The system to use for this purpose consists of flour Low energy Germanium (LeGe) Camberra detectors working in the energy range from 10 to 1000 keV. Physical phantoms with a known contamination in the organ of interest are normally used for the calibration of the LEGe detection system. In this document we present a calibration method using the Monte Carlo technique (MCNP4C) over a voxel phantom obtained from a computerized tomography of a real human head. The phantom consists of 104017 (43x59x41) cubic voxels, 4 mn on each side, os specific tissues, but for this simulation only two types are taken into account: adipose tissue and hard bone. The skull is supposed to be contaminated with ''241 Am and the trajectories of the photons are simulated till they reach the germanium detectors. The detectors were also simulated in detail to obtain a good agreement with the reality. In order to verify the accuracy of this procedure to reproduce the experiments, the MCNP results are compared with laboratory measurements of a head phantom simulating an internal contamination of 1000 Bq of ''241 Am deposited in bone. Different relative positions source-detector were tried to look for the best counting geometry for measurement of a contaminated skull. Efficiency values are obtained and compared, resulting in the validation of the mathematical method for the assessment of internal contamination of American deposited in skeleton. (Author) 16 refs

  4. Effect of size and composition of the body on absolute measurement of calcium in vivo

    International Nuclear Information System (INIS)

    Spinks, T.J.

    1979-01-01

    The effect of size and composition of the body on the measurement of total calcium in absolute units by neutron activation analysis is described. The neutron beam, produced from a cyclotron, was of mean energy 7.5 MeV. Counting of the activities induced in a patient was carried out with a multidetector whole body counter. Calibration of the system was achieved by using two phantoms of different sizes containing known quantities of calcium. The dimensions of various phantom sections were varied to determine the effect on efficiency of activation, an approximately linear relationship with body thickness being found. The influence of body habitus on counting efficiency was assessed by counting different patients who had been given known quantities of 42 K. The effects of (a) the non-uniform distribution of calcium and (b) the variation in density of different tissues on both activation and counting efficiency are discussed. It is estimated that the 68% confidence limits on the measurement of 49 Ca count rate per unit neutron fluence is +- 3.0% and on the measurement of calcium in grams +- 8.2%. (author)

  5. Nordic proficiency test for whole body counting facilities

    Energy Technology Data Exchange (ETDEWEB)

    del Risco Norrlid, L. (Swedish Radiation Safety Authority (Sweden)); Halldorsson, O. (Icelandic Radiation Safety Authority, GR (Iceland)); Holm, S. (Copenhagen Univ. Hospital. NM and PET (Denmark)); Huikari, J. (Radiation and Nuclear Safety Authority (Finland)); Isaksson, M. (Goeteborg Univ., Dep. Radiation Physics Sahlgren Academy (Sweden)); Lind, B. (Norwegian Radiation Protection Authority (Norway))

    2012-01-15

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality of this kind of measurement by means of a proficiency test exercise. In this report the results of the proficiency test are presented. The exercise consisted in determining the activity of a phantom filled with two sets of certified radioactive materials, K-40 and Cs-137, in radioactive rods, uniformly spaced inside of the phantom. Most of the participants were able to quantify correctly the activities of K-40 and Cs-137 and by comparison with the results of a previous exercise of this kind, the overall performance is equally good. The problems experienced by laboratories which submitted non-acceptable results could generally be attributed to the calibration of their systems. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  6. The role of Tl-201 total body scintigraphy in follow up of thyroid carcinoma

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Delprat, C.C.; Marcuse, H.R.

    1985-01-01

    To evaluate the reliability of the procedure T1-201 total body scintigraphy was performed in 294 patients (449 studies) after total thyroidectomy for thyroid carcinoma. Results were correlated with I-131-scintigraphy and tumor-marker levels (Tgb or Calcitonin/CEA). T1-201 total body scintigraphy was negative in 196 patients with no evidence of disease. T1-201-scintigraphy correctly detected tumor localizations in 24 of 30 patients with I-131-positive metastases. In 28 patients T2-201 total body scintigraphy revealed metastases which did not concentrate I-131. Histology/cytology confirmed thyroid carcinoma metastases in 16 patients and other pathology in 5 cases. 9 of 18 patients with medullary thyroid carcinoma (I-131-negative) had elevated Calcitonin/CEA-levels. The T1-201 scintigram was positive in 8 of these patients. Comparison of T1-201, I-131 and tumor markers showed that only combined use of these parameters provide complete reliability. The authors conclude that T1-201 total body scintigraphy is useful in follow up of thyroid carcinoma, especially when a discrepancy of the other parameters exists and particularly in medullary carcinoma. In long term follow up of patients who are unsuspected of disease after successful therapy for thyroid carcinoma one can rely on T1-201 total body scintigraphy in combination with tumor marker assays

  7. Total motile sperm count: a better indicator for the severity of male factor infertility than the WHO sperm classification system

    NARCIS (Netherlands)

    Hamilton, J.A.; Cissen, M.; Brandes, M.; Smeenk, J.M.; Bruin, J.P. de; Kremer, J.A.M.; Nelen, W.L.D.M.; Hamilton, C.J.C.M.

    2015-01-01

    STUDY QUESTION: Does the prewash total motile sperm count (TMSC) have a better predictive value for spontaneous ongoing pregnancy (SOP) than the World Health Organization (WHO) classification system? SUMMARY ANSWER: The prewash TMSC shows a better correlation with the spontaneous ongoing pregnancy

  8. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    Science.gov (United States)

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  9. Combined modality therapy of diffuse histology non-Hodgkin's lymphoma with cyclophosphamide, adriamycin, vincristine, prednisone (CHOP) and total body irradiation

    International Nuclear Information System (INIS)

    Weick, J.K.; Antunez, A.; Kraus, T.A.; Fabian, C.J.; Dixon, D.

    1983-01-01

    The combination of cyclophosphamide, adriamycin, vincristine, and prednisone (CHOP) alternating with total body irradiation (TBI) has been shown earlier to be effective therapy in patients with malignant lymphoma who have received prior chemotherapy and/or radiation therapy. A limited institutional pilot study was therefore done by the Southwest Oncology Group between October 1977, and November 1978 to test the benefit of this program in previously untreated persons with Stages 3 and 4 diffuse histology non-Hodgkin's lymphoma. Eleven evaluable patients with the following histologies were treated: 7 poorly differentiated, 2 with histiocytic, 1 with mixed lymphoma and 1 with well-differentiated morphology. Responses were seen in 8/11 patients (6 CR and 2 PR); 5 persons are currently alive and 6 are dead. The median duration of remission is 15 months and the median survival for all patients is 48 months. The therapy was well tolerated with a mean nadir leukocyte count of 3020 x 10 9 /μl (range 1.2 to 5.5) and a mean nadir platelet count of 188 x 10 9 /μl (range 016 to 270). As delivered, this program is capable of producing durable remissions and needs to be verified in a larger series of patients

  10. Radiological protection in a patient during a total body irradiation procedure

    International Nuclear Information System (INIS)

    Hernandez O, J. O.; Hinojosa G, J.; Gomez M, E.; Balam de la Vega, J. A.; Deheza V, J. C.

    2010-09-01

    A technique used in the Service of Radiotherapy of the Cancer Center of the American British Cowdray Medical Center (ABC) for the bone marrow transplantation, is the total body irradiation. It is known that the dose calculation, for this irradiation type, is old, since the dosimetric calculation is carried out by hand and they exist infinity of techniques for the patients irradiation and different forms of protecting organs of risk, as well as a great uncertainty in the given dose. In the Cancer Center of the ABC Medical Center, was carried out an irradiation procedure to total body with the following methodology: Computerized tomography of the patient total body (two vacuum mattresses in the following positions: dorsal and lateral decubitus), where is combined the two treatment techniques anterior-posterior and bilateral, skin delineate and reference volumes, dose calculation with the planning system Xi O of CMS, dose determination using an ionization chamber and a lung phantom IMRT Thorax Phantom of the mark CIRS and dosimetry in vivo. In this work is presented the used treatment technique, the results, statistics and the actualization of the patient clinical state. (Author)

  11. Measurement of total body chlorine by prompt gamma in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Beddoe, A.H.; Streat, S.J.; Hill, G.L.

    1987-01-01

    A method of measuring total body chlorine (TBCl) by prompt gamma in vivo neutron activation analysis is described depending on the same NaI(Tl) spectra used for determinations of total body nitrogen. Ratios of chlorine to hydrogen are derived and TBCl determined using a model of body composition depending on measured body weight, total body water (by tritium dilution) and protein (6.25 x nitrogen) as well as estimated body minerals and glycogen. The precision of the method based on scanning an anthropomorphic phantom is approximately 9% (SD), for a patient dose equivalent of less than 0.30 mSv. Spectra collected from 67 normal volunteers (32 male, 35 female) yielded mean values of TBCl of 72 +- 19 (SD) g in males and 53.6 +- 15 g in females, in broad agreement with values reported by workers using delayed gamma methods. Results are presented for two human cadavers analysed by neutron activation and conventional chemical analysis; the ratios of TBCl (neutron activation) to TBCl (chemical) were 0.980 +- 0.028 (SEM) and 0.91 +- 0.09. It is suggested that an improvement in precision will be achieved by increasing the scanning time (thereby increasing the radiation dose equivalent) and by adding two more detectors. (author)

  12. Seasonal changes in total body water; body composition and water turnover in reindeer

    Directory of Open Access Journals (Sweden)

    Terje S. Larsen

    1985-05-01

    Full Text Available Total body water and water turnover were measured at different times throughout the year in 3 captive Norwegian reindeer, using a tritiated water dilution method (Holleman et al. 1982. Total body water (percent of body weight increased during late autumn and winter, from 59.1 ± 1.5 % in October to 72.5 ± 2.0 % in April. Using the equatation by Pace and Rathbun (1945 for predicting total body fat (% fat = 100 - % water/0.732, this increase in total body water indicates a concomitant reduction in body fat, from a maximum value of 18.9 ± 2.6 % (of body weight in October to a minimum of 0.9 ± 2.7 % in April. During summer, on the other hand, fat content increased at the expense of a reduced percentage of body water. Water turnover was low in winter (December - April, ranging between 30.8 ± 5.2and43.6 ± 13.5ml.d-'. kg-1, but increased nearly fourfold during summer (June-August with a maximum of 117.7 ± 5.9 ml.d-1. kg-1 in August. Positive correlations between water turnover and food intake and between water turnover and ambient temperature were found, the latter probably resulting from an incidental correlation between food intake and ambient temperature.Sesongmessige forandringer i totalt kroppsvann, kropps-sammensetning og vannomsetning hos reinsdyr.Abstract in Norwegian / Sammendrag: Totalt kroppsvann og vannomsetning av vann ble målt til forskjellige årstider i 3 norske reinsdyr ved hjelp av utvasking av tritiert vann (Holleman et al. 1982. Totalt kroppsvann (prosent av kroppsvekt økte utover høsten og vinteren, fra 59.1 ± 1.5 % i oktober til 72.5 ± 2.0 % i april. Ved hjelp av en ligning som er gitt av Pace og Rathbun (1945 for beregning av totalt kroppsfett (% fett = 100 - % vann/0.732, fant en at denne økningen i vanninnhold tilsvarte en samtidig reduksjon i fettinnhold, fra en maksimums-verdi på 18.9 ± 2.6 % av kroppsvekt i oktober til et minimum på 0.9 ± 2.7 % i april. Utover sommeren økte derimot innholdet av fett p

  13. Anomalies from aerial spectrometric and total count radiometric surveys in the southeastern United States

    International Nuclear Information System (INIS)

    Lee, C.H.; Lawton, D.E.

    1978-01-01

    Aerial radiometric reconnaissance surveys are conducted because of their cost, time, and manpower savings compared to surface studies. Two types of aerial surveys are being flown in the southeastern United States: total count gamma-ray surveys for the Coastal Plains Regional Commission and the US Geological Survey, and differential gamma-ray spectrometric surveys for the US Department of Energy. Anomalous radioactivity detected during aerial surveys is related to higher concentrations of naturally occurring uranium, or to cultural activities, natural causes, or mapping errors which simulate real uranium anomalies. Each anomaly should be ground checked; however, several types of anomalies may be eliminated by evaluation of the aerial data in the office if field time is limited

  14. Berkeley Low Background Facility

    International Nuclear Information System (INIS)

    Thomas, K. J.; Norman, E. B.; Smith, A. R.; Poon, A. W. P.; Chan, Y. D.; Lesko, K. T.

    2015-01-01

    The Berkeley Low Background Facility (BLBF) at Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California provides low background gamma spectroscopy services to a wide array of experiments and projects. The analysis of samples takes place within two unique facilities; locally within a carefully-constructed, low background laboratory on the surface at LBNL and at the Sanford Underground Research Facility (SURF) in Lead, SD. These facilities provide a variety of gamma spectroscopy services to low background experiments primarily in the form of passive material screening for primordial radioisotopes (U, Th, K) or common cosmogenic/anthropogenic products; active screening via neutron activation analysis for U,Th, and K as well as a variety of stable isotopes; and neutron flux/beam characterization measurements through the use of monitors. A general overview of the facilities, services, and sensitivities will be presented. Recent activities and upgrades will also be described including an overview of the recently installed counting system at SURF (recently relocated from Oroville, CA in 2014), the installation of a second underground counting station at SURF in 2015, and future plans. The BLBF is open to any users for counting services or collaboration on a wide variety of experiments and projects

  15. Flow cytometry total cell counts : A field study assessing microbiological water quality and growth in unchlorinated drinking water distribution systems

    NARCIS (Netherlands)

    Liu, G.; Van der Mark, E.J.; Verberk, J.Q.; Van Dijk, J.C.

    2013-01-01

    e objective of this study was to evaluate the application of flow cytometry total cell counts (TCCs) as a parameter to assess microbial growth in drinking water distribution systems and to determine the relationships between different parameters describing the biostability of treated water. A

  16. Age, gender, and race/ethnic differences in total body and subregional bone density.

    Science.gov (United States)

    Looker, A C; Melton, L J; Harris, T; Borrud, L; Shepherd, J; McGowan, J

    2009-07-01

    Total body bone density of adults from National Health and Nutrition Examination Survey (NHANES) 1999-2004 differed as expected for some groups (men>women and blacks>whites) but not others (whites>Mexican Americans). Cross-sectional age patterns in bone mineral density (BMD) of older adults differed at skeletal sites that varied by degree of weight-bearing. Total body dual-energy X-ray absorptiometry (DXA) data offer the opportunity to compare bone density of demographic groups across the entire skeleton. The present study uses total body DXA data (Hologic QDR 4500A, Hologic, Bedford MA, USA) from the NHANES 1999-2004 to examine BMD of the total body and selected skeletal subregions in a wide age range of adult men and women from three race/ethnic groups. Total body, lumbar spine, pelvis, right leg, and left arm BMD and lean mass from 13,091 adults aged 20 years and older were used. The subregions were chosen to represent sites with different degrees of weight-bearing. Mean BMD varied in expected ways for some demographic characteristics (men>women and non-Hispanic blacks>non-Hispanic whites) but not others (non-Hispanic whites>Mexican Americans). Differences in age patterns in BMD also emerged for some characteristics (sex) but not others (race/ethnicity). Differences in cross-sectional age patterns in BMD and lean mass by degree of weight-bearing in older adults were observed for the pelvis, leg, and arm. This information may be useful for generating hypotheses about age, race, and sex differences in fracture risk in the population.

  17. Total body skeletal muscle mass: estimation by creatine (methyl-d3) dilution in humans

    Science.gov (United States)

    Walker, Ann C.; O'Connor-Semmes, Robin L.; Leonard, Michael S.; Miller, Ram R.; Stimpson, Stephen A.; Turner, Scott M.; Ravussin, Eric; Cefalu, William T.; Hellerstein, Marc K.; Evans, William J.

    2014-01-01

    Current methods for clinical estimation of total body skeletal muscle mass have significant limitations. We tested the hypothesis that creatine (methyl-d3) dilution (D3-creatine) measured by enrichment of urine D3-creatinine reveals total body creatine pool size, providing an accurate estimate of total body skeletal muscle mass. Healthy subjects with different muscle masses [n = 35: 20 men (19–30 yr, 70–84 yr), 15 postmenopausal women (51–62 yr, 70–84 yr)] were housed for 5 days. Optimal tracer dose was explored with single oral doses of 30, 60, or 100 mg D3-creatine given on day 1. Serial plasma samples were collected for D3-creatine pharmacokinetics. All urine was collected through day 5. Creatine and creatinine (deuterated and unlabeled) were measured by liquid chromatography mass spectrometry. Total body creatine pool size and muscle mass were calculated from D3-creatinine enrichment in urine. Muscle mass was also measured by magnetic resonance imaging (MRI), dual-energy x-ray absorptiometry (DXA), and traditional 24-h urine creatinine. D3-creatine was rapidly absorbed and cleared with variable urinary excretion. Isotopic steady-state of D3-creatinine enrichment in the urine was achieved by 30.7 ± 11.2 h. Mean steady-state enrichment in urine provided muscle mass estimates that correlated well with MRI estimates for all subjects (r = 0.868, P creatine dose determined by urine D3-creatinine enrichment provides an estimate of total body muscle mass strongly correlated with estimates from serial MRI with less bias than total lean body mass assessment by DXA. PMID:24764133

  18. In Vivo Radiobioassay and Research Facility

    International Nuclear Information System (INIS)

    Lynch, Timothy P.

    2011-01-01

    Bioassay monitoring for intakes of radioactive material is an essential part of the internal dosimetry program for radiation workers at the Department of Energy's (DOE) Hanford Site. This monitoring program includes direct measurements of radionuclides in the body by detecting photons that exit the body and analyses of radionuclides in excreta samples. The specialized equipment and instrumentation required to make the direct measurements of these materials in the body are located at the In Vivo Radiobioassay and Research Facility (IVRRF). The IVRRF was originally built in 1960 and was designed expressly for the in vivo measurement of radioactive material in Hanford workers. Most routine in vivo measurements are performed annually and special measurements are performed as needed. The primary source terms at the Hanford Site include fission and activation products (primarily 137Cs and 90Sr), uranium, uranium progeny, and transuranic radionuclides. The facility currently houses five shielded counting systems, men's and women's change rooms and an instrument maintenance and repair shop. Four systems include high purity germanium detectors and one system utilizes large sodium iodide detectors. These systems are used to perform an average of 7,000 measurements annually. This includes approximately 5000 whole body measurements analyzed for fission and activation products and 2000 lung measurements analyzed for americium, uranium, and plutonium. Various other types of measurements are performed periodically to estimate activity in wounds, the thyroid, the liver, and the skeleton. The staff maintains the capability to detect and quantify activity in essentially any tissue or organ. The in vivo monitoring program that utilizes the facility is accredited by the Department of Energy Laboratory Accreditation Program for direct radiobioassay.

  19. Calibration of whole-body counters for transuranic radionuclides by using total-body donations to the United States Transuranium Registry

    International Nuclear Information System (INIS)

    Palmer, H.E.; Heid, K.R.; Breitenstein, B.D.; Durbin, P.W.; McInroy, J.F.

    1985-01-01

    One of the many benefits of the whole-body donation programme of the United States Transuranium Registry is the calibration of whole-body counters by measuring a donated body containing radioactivity before radiochemical analysis of the body occurs. These measurements have provided the best existing calibration factors for measuring 241 Am and 239 Pu in the skeleton of living people. In one case where the body contained an easily measurable quantity of 241 Am, the 241 Am content was found to be the same for identical bones on the right and left sides of the body. The bones from the right side of the body and every other vertebrae were radiochemically analysed and the bones from the left side were reserved. These latter have a known quantity of naturally distributed 241 Am based on the analysis of bones from the right side. These reserved bones are being incorporated into tissue equivalent body parts for future calibrations and interlaboratory comparisons. The measurements on the total body and the reserved bones have already been very useful in determining the contribution of skeletal activity to that of lung measurements and determining a calibration factor for measuring 239 Pu deposited in the skeleton. In the future it is planned to periodically make in vivo measurements on those people participating in the total-body donation programme so that calibration factors can be obtained for lung and liver content after subsequent analysis of these tissues. (author)

  20. Preliminary stochastic model for managing Vibrio parahaemolyticus and total viable bacterial counts in a Pacific oyster (Crassostrea gigas) supply chain.

    Science.gov (United States)

    Fernandez-Piquer, Judith; Bowman, John P; Ross, Tom; Estrada-Flores, Silvia; Tamplin, Mark L

    2013-07-01

    Vibrio parahaemolyticus can accumulate and grow in oysters stored without refrigeration, representing a potential food safety risk. High temperatures during oyster storage can lead to an increase in total viable bacteria counts, decreasing product shelf life. Therefore, a predictive tool that allows the estimation of both V. parahaemolyticus populations and total viable bacteria counts in parallel is needed. A stochastic model was developed to quantitatively assess the populations of V. parahaemolyticus and total viable bacteria in Pacific oysters for six different supply chain scenarios. The stochastic model encompassed operations from oyster farms through consumers and was built using risk analysis software. Probabilistic distributions and predictions for the percentage of Pacific oysters containing V. parahaemolyticus and high levels of viable bacteria at the point of consumption were generated for each simulated scenario. This tool can provide valuable information about V. parahaemolyticus exposure and potential control measures and can help oyster companies and regulatory agencies evaluate the impact of product quality and safety during cold chain management. If coupled with suitable monitoring systems, such models could enable preemptive action to be taken to counteract unfavorable supply chain conditions.

  1. Software application for a total management of a radioactive facility

    International Nuclear Information System (INIS)

    Mirpuri, E.; Escudero, R.; Macias, M.T.; Perez, J.; Sanchez, A.; Usera, F.

    2008-01-01

    The use of radiological material and/or equipment that generate ionizing radiation is widely extended in biological research. In every laboratory there are a large variety of methods, operations, techniques, equipment, radioisotopes and users related to the work with ionizing radiation. In order to control the radioactive material, users and the whole facility a large number of documents, databases and information is necessary to be created by the manager of the Radioactivity Facility. This kind of information is characterized by a constant and persistent manipulation and includes information of great importance such as the general management of the radioactive material and waste management, exposed workers vigilance, controlled areas access, laboratory and equipment reservations, radiological inspections, etc. These activities are often complicated by the fact that the main manager of the radioactive facility is also in charge of bio-safety and working prevention issues so the documents to generate and manipulate and the procedures to develop are multiplied. A procedure to access and manage all these files is highly recommended in order to optimize the general management of the facility, avoiding loss of information, automating all the activities and allowing data necessary for control easily accessible. In this work we present a software application for a total management of the facility. This software has been developed by the collaboration of six of the most important research centers from Spain in coordination with the company 'Appize soluciones'. This is a flexible and versatile application that adapts to any specific need of every research center, providing the appropriate reports and checklist that speed up to general management and increase the ease of writing the official documents, including the Operations Book. (author)

  2. Clinical Perspective of 3D Total Body Photography for Early Detection and Screening of Melanoma.

    Science.gov (United States)

    Rayner, Jenna E; Laino, Antonia M; Nufer, Kaitlin L; Adams, Laura; Raphael, Anthony P; Menzies, Scott W; Soyer, H Peter

    2018-01-01

    Melanoma incidence continues to increase across many populations globally and there is significant mortality associated with advanced disease. However, if detected early, patients have a very promising prognosis. The methods that have been utilized for early detection include clinician and patient skin examinations, dermoscopy (static and sequential imaging), and total body photography via 2D imaging. Total body photography has recently witnessed an evolution from 2D imaging with the ability to now create a 3D representation of the patient linked with dermoscopy images of individual lesions. 3D total body photography is a particularly beneficial screening tool for patients at high risk due to their personal or family history or those with multiple dysplastic naevi-the latter can make monitoring especially difficult without the assistance of technology. In this perspective, we discuss clinical examples utilizing 3D total body photography, associated advantages and limitations, and future directions of the technology. The optimal system for melanoma screening should improve diagnostic accuracy, be time and cost efficient, and accessible to patients across all demographic and socioeconomic groups. 3D total body photography has the potential to address these criteria and, most importantly, optimize crucial early detection.

  3. Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care.

    Science.gov (United States)

    Cherry, Simon R; Jones, Terry; Karp, Joel S; Qi, Jinyi; Moses, William W; Badawi, Ramsey D

    2018-01-01

    PET is widely considered the most sensitive technique available for noninvasively studying physiology, metabolism, and molecular pathways in the living human being. However, the utility of PET, being a photon-deficient modality, remains constrained by factors including low signal-to-noise ratio, long imaging times, and concerns about radiation dose. Two developments offer the potential to dramatically increase the effective sensitivity of PET. First by increasing the geometric coverage to encompass the entire body, sensitivity can be increased by a factor of about 40 for total-body imaging or a factor of about 4-5 for imaging a single organ such as the brain or heart. The world's first total-body PET/CT scanner is currently under construction to demonstrate how this step change in sensitivity affects the way PET is used both in clinical research and in patient care. Second, there is the future prospect of significant improvements in timing resolution that could lead to further effective sensitivity gains. When combined with total-body PET, this could produce overall sensitivity gains of more than 2 orders of magnitude compared with existing state-of-the-art systems. In this article, we discuss the benefits of increasing body coverage, describe our efforts to develop a first-generation total-body PET/CT scanner, discuss selected application areas for total-body PET, and project the impact of further improvements in time-of-flight PET. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  4. Automated uranium analysis by delayed-neutron counting

    International Nuclear Information System (INIS)

    Kunzendorf, H.; Loevborg, L.; Christiansen, E.M.

    1980-10-01

    Automated uranium analysis by fission-induced delayed-neutron counting is described. A short description is given of the instrumentation including transfer system, process control, irradiation and counting sites, and computer operations. Characteristic parameters of the facility (sample preparations, background, and standards) are discussed. A sensitivity of 817 +- 22 counts per 10 -6 g U is found using irradiation, delay, and counting times of 20 s, 5 s, and 10 s, respectively. Presicion is generally less than 1% for normal geological samples. Critical level and detection limits for 7.5 g samples are 8 and 16 ppb, respectively. The importance of some physical and elemental interferences are outlined. Dead-time corrections of measured count rates are necessary and a polynomical expression is used for count rates up to 10 5 . The presence of rare earth elements is regarded as the most important elemental interference. A typical application is given and other areas of application are described. (auther)

  5. Gastrointestinal decontamination of dogs treated with total body irradiation and bone marrow transplantation

    NARCIS (Netherlands)

    Vriesendorp, H.M.; Heidt, P.J.; Zurcher, C.

    1981-01-01

    Procedures for total and selective gastrointestinal decontamination of dogs are described. The selective procedure removed only Gram negative aerobic bacteria, yeast and fungi. Dogs receiving total decontamination were less susceptible to the GI syndrome following total body irradiation (TBI) than

  6. Device for treating plastic counting vials containing radioactive liquids

    International Nuclear Information System (INIS)

    Neidhart, B.; Brindoepke, H.W.; Flocke, W.; Kringe, K.P.; Lippmann, C.H.

    1985-01-01

    The treatment consists of separating the radioactive contents of the counting vial from its plastic components. The apparatus consists of a device for continuously supplying the counting vials to be treated, a means for crushing the vials into chips of plastic and a facility by means of which the radioactive contents of the counting vial and the separated plastic chips are collected separately from one another. A stirring assembly with a motor-driven stirrer and an alignment device are also provided. The radioactive substances pass through a sieve while the plastic chips slide down the sieve chute and into another container. All the metal parts of the facility are of stainless steel. The plastic chips collected in the sieve holder are washed and, after drying, are removed as negligibly radioactive solids. The weakly radioactive wash liquid is separated and collected. (orig./PW)

  7. Radioactive facilities classification criteria

    International Nuclear Information System (INIS)

    Briso C, H.A.; Riesle W, J.

    1992-01-01

    Appropriate classification of radioactive facilities into groups of comparable risk constitutes one of the problems faced by most Regulatory Bodies. Regarding the radiological risk, the main facts to be considered are the radioactive inventory and the processes to which these radionuclides are subjected. Normally, operations are ruled by strict safety procedures. Thus, the total activity of the radionuclides existing in a given facility is the varying feature that defines its risk. In order to rely on a quantitative criterion and, considering that the Annual Limits of Intake are widely accepted references, an index based on these limits, to support decisions related to radioactive facilities, is proposed. (author)

  8. Calibration Human Voxel Phantoms for In Vivo Measurement of ''2 sup 4 sup 1 Am in Bone at the Whole Body Counter Facility of CIEMAT

    CERN Document Server

    Moraleda, M; Navarro, J F; Navarro, T

    2002-01-01

    The Whole Body Counting facility of CIEMAT is capable of carrying out In-Vivo measurements of radionuclides emitting X-rays and low energy gamma radiation internally deposited in the body. The system to use for this purpose consists of flour Low energy Germanium (LeGe) Camberra detectors working in the energy range from 10 to 1000 keV. Physical phantoms with a known contamination in the organ of interest are normally used for the calibration of the LEGe detection system. In this document we present a calibration method using the Monte Carlo technique (MCNP4C) over a voxel phantom obtained from a computerized tomography of a real human head. The phantom consists of 104017 (43x59x41) cubic voxels, 4 mn on each side, os specific tissues, but for this simulation only two types are taken into account: adipose tissue and hard bone. The skull is supposed to be contaminated with ''241 Am and the trajectories of the photons are simulated till they reach the germanium detectors. The detectors were also simulated in det...

  9. Computer-based anthropometrical system for total body irradiation.

    Science.gov (United States)

    Sánchez-Nieto, B; Sánchez-Doblado, F; Terrón, J A; Arráns, R; Errazquin, L

    1997-05-01

    For total body irradiation (TBI) dose calculation requirements, anatomical information about the whole body is needed. Despite the fact that video image grabbing techniques are used by some treatment planning systems for standard radiotherapy, there are no such systems designed to generate anatomical parameters for TBI planning. The paper describes an anthropometrical computerised system based on video image grabbing which was purpose-built to provide anatomical data for a PC-based TBI planning system. Using software, the system controls the acquisition and digitalisation of the images (external images of the patient in treatment position) and the measurement procedure itself (on the external images or the digital CT information). An ASCII file, readable by the TBI planning system, is generated to store the required parameters of the dose calculation points, i.e. depth, backscatter tissue thickness, thickness of inhomogeneity, off-axis distance (OAD) and source to skin distance (SSD).

  10. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  11. Design and development of multiple sample counting setup

    International Nuclear Information System (INIS)

    Rath, D.P.; Murali, S.; Babu, D.A.R.

    2010-01-01

    Full text: The analysis of active samples on regular basis for ambient air activity and floor contamination from radio chemical lab accounts for major chunk of the operational activity in Health Physicist's responsibility. The requirement for daily air sample analysis on immediate counting and delayed counting from various labs in addition to samples of smear swipe check of lab led to the urge for development of system that could cater multiple sample analysis in a time programmed manner on a single sample loading. A multiple alpha/beta counting system for counting was designed and fabricated. It has arrangements for loading 10 samples in slots in order, get counted in a time programmed manner with results displayed and records maintained in PC. The paper describes the design and development of multiple sample counting setup presently in use at the facility has resulted in reduction of man-hour consumption in counting and recording of the results

  12. The utility of point count surveys to predict wildlife interactions with wind energy facilities: An example focused on golden eagles

    Science.gov (United States)

    Sur, Maitreyi; Belthoff, James R.; Bjerre, Emily R.; Millsap, Brian A.; Katzner, Todd

    2018-01-01

    Wind energy development is rapidly expanding in North America, often accompanied by requirements to survey potential facility locations for existing wildlife. Within the USA, golden eagles (Aquila chrysaetos) are among the most high-profile species of birds that are at risk from wind turbines. To minimize golden eagle fatalities in areas proposed for wind development, modified point count surveys are usually conducted to estimate use by these birds. However, it is not always clear what drives variation in the relationship between on-site point count data and actual use by eagles of a wind energy project footprint. We used existing GPS-GSM telemetry data, collected at 15 min intervals from 13 golden eagles in 2012 and 2013, to explore the relationship between point count data and eagle use of an entire project footprint. To do this, we overlaid the telemetry data on hypothetical project footprints and simulated a variety of point count sampling strategies for those footprints. We compared the time an eagle was found in the sample plots with the time it was found in the project footprint using a metric we called “error due to sampling”. Error due to sampling for individual eagles appeared to be influenced by interactions between the size of the project footprint (20, 40, 90 or 180 km2) and the sampling type (random, systematic or stratified) and was greatest on 90 km2 plots. However, use of random sampling resulted in lowest error due to sampling within intermediate sized plots. In addition sampling intensity and sampling frequency both influenced the effectiveness of point count sampling. Although our work focuses on individual eagles (not the eagle populations typically surveyed in the field), our analysis shows both the utility of simulations to identify specific influences on error and also potential improvements to sampling that consider the context-specific manner that point counts are laid out on the landscape.

  13. EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)

    Science.gov (United States)

    Cherry, Simon R.; Badawi, Ramsey D.; Jones, Terry

    2016-04-01

    Positron emission tomography (PET) is the highest sensitivity technique for human whole-body imaging studies. However, current clinical PET scanners do not make full use of the available signal, as they only permit imaging of a 15-25 cm segment of the body at one time. Given the limited sensitive region, whole-body imaging with clinical PET scanners requires relatively long scan times and subjects the patient to higher than necessary radiation doses. The EXPLORER initiative aims to build a 2-meter axial length PET scanner to allow imaging the entire subject at once, capturing nearly the entire available PET signal. EXPLORER will acquire data with ~40-fold greater sensitivity leading to a six-fold increase in reconstructed signal-to-noise ratio for imaging the total body. Alternatively, total-body images with the EXPLORER scanner will be able to be acquired in ~30 seconds or with ~0.15 mSv injected dose, while maintaining current PET image quality. The superior sensitivity will open many new avenues for biomedical research. Specifically for cancer applications, high sensitivity PET will enable detection of smaller lesions. Additionally, greater sensitivity will allow imaging out to 10 half-lives of positron emitting radiotracers. This will enable 1) metabolic ultra-staging with FDG by extending the uptake and clearance time to 3-5 hours to significantly improve contrast and 2) improved kinetic imaging with short-lived radioisotopes such as C-11, crucial for drug development studies. Frequent imaging studies of the same subject to study disease progression or to track response to therapy will be possible with the low dose capabilities of the EXPLORER scanner. The low dose capabilities will also open up new imaging possibilities in pediatrics and adolescents to better study developmental disorders. This talk will review the basis for developing total-body PET, potential applications, and review progress to date in developing EXPLORER, the first total-body PET scanner.

  14. Sperm motility and morphology as changing parameters linked to sperm count variations.

    OpenAIRE

    Dua A; Vaidya S

    1996-01-01

    Variations in semen analyses of 177 males over a 1 year period were assessed. The average means of total counts, motility, morphology, total motile count and non-motile % were determined for 5 classes of patients ranging from azoospermic to normospermic. Positive relationships between a falling sperm count, a decrease in motility and total motile counts were seen. Also, increasingly, abnormal forms were found with lower sperm counts.

  15. Effects of resistance training on body composition and functional capacity among sarcopenic obese residents in long-term care facilities: a preliminary study.

    Science.gov (United States)

    Chiu, Shu-Ching; Yang, Rong-Sen; Yang, Rea-Jeng; Chang, Shu-Fang

    2018-01-22

    Aging-related loss of muscle and strength with increased adiposity is prevalent among older people in long-term care (LTC) facilities. Studies have shown that people with sarcopenic obesity (SO) are at high risk of declining physical performance. At present, no interventional studies on residents with SO in nursing homes have been conducted in the literature. The objectives of this study include appraising the changes in body composition and physical performance following resistance training among residents with SO in LTC facilities. This study used a quasiexperimental research design. Residents who are 60 years of age or above and have been living a sedentary lifestyle in LTC facilities for the past 3 months will be eligible for inclusion. The intervention group engaged in chair muscle strength training twice a week for 12 weeks, whereas the control group underwent the usual care. The main variables were physical parameters of being lean and fat, the strength of grip and pinch, and a functional independence measure using descriptive analysis, chi-squared test, t-test, and generalized estimating equation for statistical analysis through SPSS. A total of 64 respondents with SO completed the study. After training, total grip strength (p = 0.001) and total pinch strength (p = 0.014) of the intervention group differed significantly from those of the control group. The right grip strength of the intervention group increased by 1.71 kg (p = 0.003) and the left grip strength improved by 1.35 kg (p = 0.028) compared with baseline values. The self-care scores of the intervention group increased by 2.76 points over baseline scores, particularly for the action of dressing oneself. Although grip strength and self-care scores improved more among those in the intervention group, body fat and skeletal muscle percentages did not differ significantly between the groups after training (p > 0.05). Resistance exercises for elderly residents in LTC facilities

  16. A Large Rice Body-Containing Cyst Mimicking Infection following Total Hip Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Wael Bayoud

    2017-01-01

    Full Text Available Introduction. Soft tissue mass following total hip arthroplasty raises several differential diagnoses not limited to infection, hematoma, wear debris, malignancy, and bursitis. Rice body formation in the hip region is an uncommon process denoting a chronic inflammation. We report here the second case of its kind in the medical literature of a wide symptomatic rice-like body cyst complicating a total hip arthroplasty. Case Presentation. This is the case of an 82-year-old white female, presenting with a warm, red, and inflated groin five years after revision of right total hip arthroplasty. Surgical intervention reveals a large well circumscribed cyst containing well-organized rice-like bodies. This eventuality was never reported in differential diagnosis of hip periprosthetic soft tissue masses before. Conclusion. This case report helps widening the array of the differential diagnosis in patients presenting with a slow growing soft tissue mass following total hip arthroplasty, making rice-like bodies cyst a valid one to consider.

  17. Biological basis of total body irradiation

    International Nuclear Information System (INIS)

    Dubray, B.; Helfre, S.; Dendale, R.; Cosset, J.M.; Giraud, P.

    1999-01-01

    A comprehensive understanding of the radiobiological bases of total body irradiation (TBI) is made difficult by the large number of normal and malignant tissues that must be taken into account. In addition, tissue responses to irradiation are also sensitive to associated treatments, type of graft and a number of patient characteristics. Experimental studies have yielded a large body of data, the clinical relevance of which still requires definite validation through randomized trials. Fractionated TBI schemes are able to reduce late normal tissue toxicity, but the ultimate consequences of the fractional dose reduction do not appear to be equivocal. Thus, leukemia and lymphoma cells are probably more radio-biologically heterogeneous than previously thought, with several cell lines displaying relatively high radioresistance and repair capability patterns. The most primitive host-type hematopoietic stem cells are likely to be at least partly protected by TBI fractionation and may hamper late engraftment. Similarly, but with possibly conflicting consequences on the probability of engraftment, the persistence of a functional marrow stroma may also be fractionation-sensitive, while higher rejection rates have been reported after T-depletion grafts and fractionated TBI. in clinical practice (as for performance of relevant clinical trials), the influence of these results are rather limited by the heavy logistic constraints created by a sophisticated and time-consuming procedure. Lastly, clinicians are now facing an increasing incidence of second cancers, at least partly induced by irradiation, which jeopardize the long-term prospects of otherwise cured patients. (authors)

  18. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: yalcin@gazi.edu.tr; Gurler, O.; Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, School of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2007-10-15

    This paper presents results on the total gamma counting efficiency of a NaI(Tl) detector from point and disk sources. The directions of photons emitted from the source were determined by Monte-Carlo techniques and the photon path lengths in the detector were determined by analytic equations depending on photon directions. This is called the hybrid Monte-Carlo method where analytical expressions are incorporated into the Monte-Carlo simulations. A major advantage of this technique is the short computation time compared to other techniques on similar computational platforms. Another advantage is the flexibility for inputting detector-related parameters (such as source-detector distance, detector radius, source radius, detector linear attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. The results of the total counting efficiency model put forward for point and disc sources were compared with the previous work reported in the literature.

  19. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Kaynak, G.; Gundogdu, O.

    2007-01-01

    This paper presents results on the total gamma counting efficiency of a NaI(Tl) detector from point and disk sources. The directions of photons emitted from the source were determined by Monte-Carlo techniques and the photon path lengths in the detector were determined by analytic equations depending on photon directions. This is called the hybrid Monte-Carlo method where analytical expressions are incorporated into the Monte-Carlo simulations. A major advantage of this technique is the short computation time compared to other techniques on similar computational platforms. Another advantage is the flexibility for inputting detector-related parameters (such as source-detector distance, detector radius, source radius, detector linear attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. The results of the total counting efficiency model put forward for point and disc sources were compared with the previous work reported in the literature

  20. Sperm motility and morphology as changing parameters linked to sperm count variations.

    Directory of Open Access Journals (Sweden)

    Dua A

    1996-10-01

    Full Text Available Variations in semen analyses of 177 males over a 1 year period were assessed. The average means of total counts, motility, morphology, total motile count and non-motile % were determined for 5 classes of patients ranging from azoospermic to normospermic. Positive relationships between a falling sperm count, a decrease in motility and total motile counts were seen. Also, increasingly, abnormal forms were found with lower sperm counts.

  1. Performance of the postwash total motile sperm count as a predictor of pregnancy at the time of intrauterine insemination: a meta-analysis

    NARCIS (Netherlands)

    van Weert, Janne-Meije; Repping, Sjoerd; van Voorhis, Bradley J.; van der Veen, Fulco; Bossuyt, Patrick M. M.; Mol, Ben W. J.

    2004-01-01

    Objective: To assess the performance and clinical value of the postwash total motile sperm count (postwash TMC) as a test to predict intrauterine insemination (IUI) outcome. Design: Meta-analysis of diagnostic tests. Setting: Tertiary fertility center. Patient(s): Patients undergoing IUI.

  2. The monocyte counts to HDL cholesterol ratio in obese and lean patients with polycystic ovary syndrome.

    Science.gov (United States)

    Usta, Akin; Avci, Eyup; Bulbul, Cagla Bahar; Kadi, Hasan; Adali, Ertan

    2018-04-10

    Women with polycystic ovary syndrome are more likely to suffer from obesity, insulin resistance, and chronic low-grade inflammation. In fact, the excessive activation of monocytes exacerbates oxidative stress and inflammation. However, high-density lipoprotein cholesterol neutralizes the pro-inflammatory and pro-oxidant effects of monocytes. The aim of this study is to investigate whether monocyte counts to high-density lipoprotein cholesterol ratio can predict the inflammatory condition in patients with polycystic ovary syndrome. In this cross-sectional study, a total of 124 women (61 of them with polycystic ovary syndrome and 63 age-matched healthy volunteers) were included in the study population. Obese polycystic ovary syndrome patients (n = 30) with a body mass index of ≥25 kg/m 2 and lean polycystic ovary syndrome patients (n = 31) with a body mass index of polycystic ovary syndrome were significantly higher than in control subjects (p = 0.0018). Moreover, a regression analysis revealed that body mass index, the homeostasis model assessment of insulin resistance and the high sensitivity C-reactive protein levels were confounding factors that affected the monocyte counts to high density lipoprotein cholesterol values. Additionally, a univariate and multivariate logistic regression analysis demonstrated that the increased monocyte counts to high density lipoprotein cholesterol values were more sensitive than the other known risk factors (such as increased body mass index, homeostasis model assessment of insulin resistance and high sensitive C-reactive protein levels) in the prediction of the inflammation in patients with polycystic ovary syndrome. The present study demonstrated that the monocyte count to high density lipoprotein cholesterol may be a novel and useful predictor of the presence of polycystic ovary syndrome.

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. Working... Not now Try it free Find ...

  4. Changes in body composition of cancer patients following combined nutritional support

    International Nuclear Information System (INIS)

    Cohn, S.H.; Vartsky, D.; Vaswani, A.N.; Sawitsky, A.; Rai, K.; Gartenhaus, W.; Yasumura, S.; Ellis, K.J.

    1982-01-01

    The effects of combined nutritional support (parenteral, enteral, and oral) were measured in cancer patients unable to maintain normal alimentation.Changes in body composition were quantified by measurement of total body levels of nitrogen, potassium, water, and fat. The protein-calorie intake of the patients was also evaluated by dietary survey (4-day recall). Standard anthropometric and biochemical measurements for nutritional assessment were obtained for comparison. The dietary evaluation indicated that the dietary supplementation for all patients was more than adequate to meet their energy requirements. Determination of body composition indicated that change in body weight was equal to the sum of the changes in body protein, total body water, and total body fat. Information on the nature of the tissue gained was obtained by comparison of body composition data with the ratio of protein:water:lean body mass for normal tissue. The mean gain of protein in the cancer patients was quite small (0.3-0.6 kg). The main change in body weight appeared to be the result of gains in body water and body fat. The total body nitrogen to potassium ratio served to define the extent of tissue anabolism following hyperalimentation. The ratio dropped in the cancer patients following hyperalimentation toward the value of the control subjects on ad libitum diets. Total body nitrogen was determined by prompt gamma neutron activation analysis, total body potassium by whole-body counting

  5. New experimental limits on heavy neutrino mixing in 8B decay obtained with the BOREXINO counting test facility

    International Nuclear Information System (INIS)

    Back, H.O.; Hagner, C.; Vogelaar, R.B.

    2003-01-01

    If heavy neutrinos with mass m νH ≥2m e are emitted in the decays of 8 B in the Sun, then decays ν H →ν L +e + +e - should be observed. The results of background measurements with the BOREXINO Counting Test Facility have been used to obtain bounds on the number of these decays. As a result, new limits on the coupling |U eH | 2 of a massive neutrino in the range of 1.1 to 12 MeV have been derived (|U eH | 2 ≤10 -3 -10 -5 ). The obtained limits on the mixing parameter are stronger than those obtained in the previous experiments using nuclear reactors and accelerators

  6. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  7. A solution for 40K interference from K internal to the human body, in an underground high sensitivity whole body counter at the Waste Isolation Pilot Plant, Carlsbad, NM, USA

    Directory of Open Access Journals (Sweden)

    I. Pillalamarri

    2017-10-01

    Full Text Available The objective of the present work is to find a solution for the interference arising from 1461 keV photons emitted by 40K in natural K internal to the human body in the detection of 241Am and 210Pb activities at the level of 37 mBq (1 pCi. The response of a broad energy Ge (BEGe reference crystal to 1461 keV photons was simulated using GEANT4 code. Simulations were performed for a point source without and with shielding, as well as for a Bottle Manikin Absorption (BOMAB phantom in the shielded whole-body counting chamber (WBC. The WBC facility is located underground at the Waste Isolation Pilot Plant, Carlsbad, NM, USA. The simulation results were discussed with regards to the interference in detecting the 241Am and 210 Pb at the level of 37 mBq (1 pCi. The specific conclusion is that the interference counts from 40K activity at the natural levels present in the human body in typical clinical settings were found to be greater than the 210Pb and 241Am signal counts from 37 mBq (1 pCi, when a 38.1 mm diameter, 25.4 mm thick BEGe reference crystal was used. Our solution for minimizing the interference to the desired precision at the specified levels was found by sacrificing the broad energy response of the counting system.

  8. Evaluation of safe use of 188Re-HEDP comparing urine data and whole body counting in gamma camera

    International Nuclear Information System (INIS)

    Paolino, Andrea; Teran, Mariella; Savio, Eduardo; Coppe, Fatima; Lopez, Andrea; Hermida, Juan C.; Gaudiano, Javier

    2008-01-01

    Cancer is the second more frequent cause of death, after cardiovascular disease, in developing countries. Most of adult patients with neoplasms will develop skeletal metastases that can lead to progressive pain. 188 Re emits both beta particles suitable for therapy and a gamma ray (155 keV), adequate for diagnostic imaging in order to verify localization in the pain areas associated to metastatic process. The aim of this work was to correlate 188 Re-HEDP dose estimations using biological samples and direct measures. All the patients had breast or prostate cancer, with bone metastases. Each patient received a tracer dose of 185 MBq of radiopharmaceutical. Urine samples were collected at 0-1, 1-2, 2-4 and, 4-6 hours post administration, and measured in dose calibrator. Whole body counts were acquired using a camera without collimator, window centered at 155 KeV, matrix 256 x 256, during 60 seconds. Data were obtained at 1 and 6 hours post administration with the patient in sitting position at 2 meter from the detector. Percentage of injected dose was calculated both for urine samples and image for each patient. The number of disintegrations was determined for organs in which higher concentration of activity was observed: those involved in the excretion, red marrow and the reminder of the body. Total doses were estimated using OLINDA/EXM software. Conclusions: Data showed that the organs chosen as more compromised during the tracer dose procedure received very low effective doses. A good correlation between calculations performed both for image and urine samples was obtained. Safety of the radiopharmaceutical was also verified using this method. (author)

  9. Simultaneous use of 82Br and 24Na radionuclides in the whole-body counting of animals by high-resolution gamma-ray spektrometry

    Czech Academy of Sciences Publication Activity Database

    Pavelka, Stanislav; Babický, Arnošt; Vobecký, Miloslav

    2008-01-01

    Roč. 278, č. 3 (2008), s. 571-574 ISSN 0236-5731 Grant - others:EC(XE) LSHG-CT-2004-511978 Institutional research plan: CEZ:AV0Z50110509; CEZ:AV0Z40310501 Keywords : gamma-spectrometry * whole-body counting * radionuclide Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.659, year: 2008

  10. Household Consumption of Food-Away-From-Home: Total Expenditure and by Type of Food Facility

    OpenAIRE

    Vicki A. McCracken; Jon A. Brandt

    1987-01-01

    Consistent with prior expectations based on household production theory, household income, time value, size and composition, and the environment in which production and consumption occurred were all important determinants of total household expenditures on food-away-from-home. However, the importance of these factors varied by type of food facility: conventional restaurants, fast-food facilities, and other commercial establishments. Decomposition of the tobit elasticities indicated the differ...

  11. Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.

    Science.gov (United States)

    Hod, E A; Brugnara, C; Pilichowska, M; Sandhaus, L M; Luu, H S; Forest, S K; Netterwald, J C; Reynafarje, G M; Kratz, A

    2018-02-01

    Automated cell counters have replaced manual enumeration of cells in blood and most body fluids. However, due to the unreliability of automated methods at very low cell counts, most laboratories continue to perform labor-intensive manual counts on many or all cerebrospinal fluid (CSF) samples. This multicenter clinical trial investigated if the GloCyte System (Advanced Instruments, Norwood, MA), a recently FDA-approved automated cell counter, which concentrates and enumerates red blood cells (RBCs) and total nucleated cells (TNCs), is sufficiently accurate and precise at very low cell counts to replace all manual CSF counts. The GloCyte System concentrates CSF and stains RBCs with fluorochrome-labeled antibodies and TNCs with nucleic acid dyes. RBCs and TNCs are then counted by digital image analysis. Residual adult and pediatric CSF samples obtained for clinical analysis at five different medical centers were used for the study. Cell counts were performed by the manual hemocytometer method and with the GloCyte System following the same protocol at all sites. The limits of the blank, detection, and quantitation, as well as precision and accuracy of the GloCyte, were determined. The GloCyte detected as few as 1 TNC/μL and 1 RBC/μL, and reliably counted as low as 3 TNCs/μL and 2 RBCs/μL. The total coefficient of variation was less than 20%. Comparison with cell counts obtained with a hemocytometer showed good correlation (>97%) between the GloCyte and the hemocytometer, including at very low cell counts. The GloCyte instrument is a precise, accurate, and stable system to obtain red cell and nucleated cell counts in CSF samples. It allows for the automated enumeration of even very low cell numbers, which is crucial for CSF analysis. These results suggest that GloCyte is an acceptable alternative to the manual method for all CSF samples, including those with normal cell counts. © 2017 John Wiley & Sons Ltd.

  12. Total body irradiation in hematopoietic stem cell transplantation

    Directory of Open Access Journals (Sweden)

    Fundagul Andic

    2014-06-01

    Full Text Available Total body irradiation is used in conjunction with chemotherapy as a conditioning regimen in the treatment of many disease such as leukemia, myelodysplastic syndrome, aplastic anemia, multiple myeloma and lymphoma prior to the hematopoetic stem cell transplantation. The main purposes of the hematopoetic stem cell transplantation are eradication of the recipient bone marrow and any residual cancer cells, creation of space in the receipient bone marrow for donor hematopoetic stem cells, and immunosuppression to prevent rejection of donor stem cells in the case of an allotransplant. [Archives Medical Review Journal 2014; 23(3.000: 398-410

  13. Serum immunoglobulin levels in humans exposed to therapeutic total-body gamma irradiation

    International Nuclear Information System (INIS)

    Chaskes, S.; Kingdon, G.C.; Balish, E.

    1975-01-01

    Reduced serum immunoglobulin (IgA, IgG, IgM) levels developed in the majority of 27 patients with hematologic disorders after treatment with 100 to 350 R total-body gamma-ray exposures at a dose rate of either 1.5 R/min to 1.5 R/hr. A reduction in IgA of 20 percent or more was found in 66 percent of the cases, while 56 percent showed an IgM decrease, and 49 percent an IgG decrease of 20 percent. The severity of immunoglobulin depression was influenced by the total radiation dose and the patient's primary disease. The occurrence of IgG and IgM depression was greater when the radiation was given at 1.5 R/hr than when the dose rate was 1.5 R/min. Substantial but incomplete recovery toward preirradiation immunoglobulin levels was found for most patients by 7 wk after total-body irradiation (TBI). (U.S.)

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  15. Increment of absolute neutrophil count in the third trimester and increased risk of small-for-gestational-age birth: Hirakata Risk Associated with Pregnancy Assessment Research (HIRAPAR).

    Science.gov (United States)

    Harita, Nobuko; Kariya, Masatoshi; Hayashi, Tomoshige; Sato, Kyoko Kogawa; Nakamura, Kimihiko; Endo, Ginji; Narimoto, Katsuhiko

    2012-09-01

    Small-for-gestational-age (SGA) infants, who have growth restriction, have higher perinatal morbidity and mortality. Excessive inflammatory reaction such as neutrophil activation has been observed in pregnant women whose offspring had restricted fetal growth, but the association between white blood cell (WBC) counts and SGA birth has not yet been assessed. We therefore examined the association of WBC count and its change with the risk of SGA birth. We enrolled 2356 pregnant women who had full-term singleton delivery at a private maternity hospital in Hirakata, Japan. SGA was defined as under the 10th percentile of birthweight for gestational age, baby sex, and mother's parity according to the Japanese neonatal anthropometric charts renewed in 2010. Blood samples were measured in the first and third trimesters. We performed multiple logistic regression analysis to assess associations between total and differential WBC counts and SGA birth. Women with SGA birth tended to have higher total WBC count in the third trimester compared with women who did not have SGA birth. This tendency was not observed for total WBC count in the first trimester. After adjustment for age, height, body mass index at entry, smoking habit, weekly gestational weight gain, and pregnancy-induced hypertension, higher total WBC count in the third trimester was associated with an increased risk of SGA birth. Total WBC count in the first trimester did not show any significant association with SGA birth. The ratio of total WBC count in the third trimester to that in the first trimester was associated with SGA birth; the odds ratio for 1 unit increase was 3.02 (95% CI: 1.54-5.92). Regarding differential WBC counts in the third trimester, neutrophil count but not lymphocyte count was associated positively with SGA birth. Higher total WBC and absolute neutrophil counts in the third trimester were associated with SGA birth. In addition, greater ratio of increase in total WBC counts during pregnancy

  16. A review of whole-body counting techniques appropriate to the study of gastrointestinal absorption

    International Nuclear Information System (INIS)

    Boddy, K.

    1976-01-01

    The wide range of whole-body counters in use for, or applicable to, the study of gastrointestinal absorption is reviewed. Shielded-room or high-sensitivity shadow-shield counters will generally be required only when there is a separate need to measure total body potassium or in studies involving pregnancy or children. For measuring gastrointestinal absorption per se, it is concluded that very simple whole-body counters of the shadow-shield or partial-shield type are usually satisfactory. These systems are of lower cost, and an economic justification for their use is derived by comparing their costs with those of hospitalizing patients for alternative investigations of gastrointestinal absorption. A resume of the general methodology is presented and some operational features and precautions are described. (author)

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 396 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 094 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 741 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 786 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ...

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 824 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 409,492 ...

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 414 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 869 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 319 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 285 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 384 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 460 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 033 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 043 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 ...

  12. Comparison of nodal staging with lean body mass based and with total body weight based in lung cancer

    International Nuclear Information System (INIS)

    Lee, H. Y.; Chung, J. K.; Kang, W. J.; So, Y.; Lee, D. S.; Lee, M. C.

    2004-01-01

    The standardized uptake (SUV) is semiquantitative evaluation parameter in positron emission tomography (PET). But there is no consensus about the application or process of SUV measurement. In this study, we used measured lean body mass (LBM) and total weight for application in SUV measurement. Also we compared the each nodal staging with SUV between measured LBM, and total weight, in non small cell lung cancer (NSCLC). Total 21 patients with lung cancer were enrolled (M:F=17:4, age 45[+-]8 years). PET-CT was done before operation with Gemini (Philips, Milpitas, U.S.). Each image was reconstructed twice with measured weight and lean body mass. Maximum SUVs of 103 dissected lymph nodes were measured and compared with histological result. For the deciding on the cut off value, receiver operating characteristic (ROC) analysis was done. 14 lymph nodes in the 103 dissected lymph nodes were metastatic lesions. From the ROC analysis, the cut off value of SUV was 1.7 with measured LBM and 2.3 with total weight. With measured LBM, Sensitivity and specificity were 92.5%. 78.2% and area under curve was 0.881. With total weight, sensitivity and specificity was 92.5% and 77%, Area under curve was 0.859. The normalization of SUV could be done with measured LBM. With the normalization of SUV with LBM, the nodal staging of NSCLC using SUV could be more accurate than using total weight in the reconstruction and measurement of SUV for lymph node lesions

  13. Immune Responses following Stereotactic Body Radiotherapy for Stage I Primary Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yoshiyasu Maehata

    2013-01-01

    Full Text Available Purpose. Immune responses following stereotactic body radiotherapy (SBRT for stage I non-small cell lung cancer (NSCLC were examined from the point of view of lymphocyte subset counts and natural killer cell activity (NKA. Patients and Methods. Peripheral blood samples were collected from 62 patients at 4 time points between pretreatment and 4 weeks post-treatment for analysis of the change of total lymphocyte counts (TLC and lymphocyte subset counts of CD3+, CD4+, CD8+, CD19+, CD56+, and NKA. In addition, the changes of lymphocyte subset counts were compared between patients with or without relapse. Further, the correlations between SBRT-related parameters and immune response were analyzed for the purpose of revealing the mechanisms of the immune response. Results. All lymphocyte subset counts and NKA at post-treatment and 1 week post-treatment were significantly lower than pre-treatment (P<0.01. No significant differences in the changes of lymphocyte subset counts were observed among patients with or without relapse. The volume of the vertebral body receiving radiation doses of 3 Gy or more (VV3 significantly correlated with the changes of nearly all lymphocyte subset counts. Conclusions. SBRT for stage I NSCLC induced significant immune suppression, and the decrease of lymphocyte subset counts may be associated with exposure of the vertebral bone marrow.

  14. Total body neutron activation analysis of calcium: calibration and normalisation

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, N S.J.; Eastell, R; Ferrington, C M; Simpson, J D; Strong, J A [Western General Hospital, Edinburgh (UK); Smith, M A; Tothill, P [Royal Infirmary, Edinburgh (UK)

    1982-05-01

    An irradiation system has been designed, using a neutron beam from a cyclotron, which optimises the uniformity of activation of calcium. Induced activity is measured in a scanning, shadow-shield whole-body counter. Calibration has been effected and reproducibility assessed with three different types of phantom. Corrections were derived for variations in body height, depth and fat thickness. The coefficient of variation for repeated measurements of an anthropomorphic phantom was 1.8% for an absorbed dose equivalent of 13 mSv (1.3 rem). Measurements of total body calcium in 40 normal adults were used to derive normalisation factors which predict the normal calcium in a subject of given size and age. The coefficient of variation of normalised calcium was 6.2% in men and 6.6% in women, with the demonstration of an annual loss of 1.5% after the menopause. The narrow range should make single measurements useful for diagnostic purposes.

  15. Phase-II trial of fractionated total body radiation in bone marrow transplantation for acute leukemia

    International Nuclear Information System (INIS)

    Gale, R.P.; Opelz, G.; Feig, S.

    1979-01-01

    The addition of low doses of fractionated total body irradiation and a radiosensitizing agent to more conventional doses of total body irradiation was well tolerated but did not improve the antileukemic effect. The DAFT regimen was not associated with a higher incidence of GVHD or interstitial pneumonitis. This observation has led us to consider escalation of the dose of FTBI in our next clinical trial

  16. Effect of milk temperature during irradiation on total bacterial count and keeping quality

    International Nuclear Information System (INIS)

    Sabbour, M.M.; Dawod, A.H.; Newigy, N.A.; Wahab, G.A.M.

    1989-01-01

    Cows' and buffaloes' milk samples were exposed to different doses of gamma radiation (100, 200 and 300 Kr) at 10 and 30°C. Irradiation of milk at 10°C caused more reduction in total bacterial count than that occurred at 30°C. The rate of microbial destruction due to irradiation at 10°C was higher than that occurred at 30°C. The keeping quality was determined daily for 15 days by clot-on-boiling test for samples kept at room temperature and in a refrigerator. The keeping quality recorded for cows' and buffaloes' milk samples in the refrigerator was 4 days, while it was only 1 day at room temperature. Irradiation of milk at 10°C was more effective than irradiation at 30°C, to increase the keeping quality of irradiated milk kept at refrigeration. Irradiation of milk samples at 10°C by 200 Kr increased the keeping quality for two weeks in the refrigerator, i.e. such a treatment increased the keeping quality by 4 folds

  17. A Triple Iron Triathlon Leads to a Decrease in Total Body Mass but Not to Dehydration

    Science.gov (United States)

    Knechtle, Beat; Knechtle, Patrizia; Rosemann, Thomas; Oliver, Senn

    2010-01-01

    A loss in total body mass during an ultraendurance performance is usually attributed to dehydration. We identified the changes in total body mass, fat mass, skeletal muscle mass, and selected markers of hydration status in 31 male nonprofessional ultratriathletes participating in a Triple Iron triathlon involving 11.4 km swimming, 540 km cycling…

  18. Particle count monitoring of reverse osmosis water treatment for removal of low-level radionuclides

    International Nuclear Information System (INIS)

    Moritz, E.J.; Hoffman, C.R.; Hergert, T.R.

    1995-01-01

    Laser diode particle counting technology and analytical measurements were used to evaluate a pilot-scale reverse osmosis (RO) water treatment system for removal of particulate matter and sub-picocurie low-level radionuclides. Stormwater mixed with Waste Water Treatment Plant (WWTP) effluent from the Rocky Flats Environmental Technology Site (RFETS), formerly a Department of Energy (DOE) nuclear weapons production facility, were treated. No chemical pretreatment of the water was utilized during this study. The treatment system was staged as follows: multimedia filtration, granular activated carbon adsorption, hollow tube ultrafiltration, and reverse osmosis membrane filtration. Various recovery rates and two RO membrane models were tested. Analytical measurements included total suspended solids (TSS), total dissolved solids (TDS), gross alpha (α) and gross beta (β) activity, uranium isotopes 233/234 U and 238 U, plutonium 239/240 Pu, and americium 241 Am. Particle measurement between 1--150 microns (μ) included differential particle counts (DPC), and total particle counts (TPC) before and after treatment at various sampling points throughout the test. Performance testing showed this treatment system produced a high quality effluent in clarity and purity. Compared to raw water levels, TSS was reduced to below detection of 5 milligrams per liter (mg/L) and TDS reduced by 98%. Gross α was essentially removed 100%, and gross β was reduced an average of 94%. Uranium activity was reduced by 99%. TPC between 1-150μ were reduced by an average 99.8% to less than 1,000 counts per milliliter (mL), similar in purity to a good drinking water treatment plant. Raw water levels of 239/240 Pu and 241 Am were below reliable quantitation limits and thus no removal efficiencies could be determined for these species

  19. Kinetics of total body retention and clearance of xenon and krypton after inhalation

    International Nuclear Information System (INIS)

    Susskind, H.; Atkins, H.L.; Cohn, S.H.; Ellis, K.J.; Richards, P.

    1976-01-01

    The total body retention of Xe-127 and Kr-79 and their clearance rates following inhalation were measured in vivo. These data are useful for refined Xe-127 dosimetry calculations, to determine the potential radiation hazard of fission product Kr-85, and more generally to study the behavior of anesthetic gases. While data are available on the solubilities and partition coefficients of Xe and Kr in fat, blood, and other individual body constituents, few measurements of their retention and clearance from the entire body have been reported

  20. Total body topical 5-fluorouracil for extensive non-melanoma skin cancer

    NARCIS (Netherlands)

    van Ruth, Serge; Jansman, Frank G. A.; Sanders, Cornelis J.

    Background Topical 5-fluorouracil 5% cream is one of the treatment modalities for non-melanoma skin cancer (NMSC). There is a lack of suitable therapies to treat patients with extensive NMSC. In this paper we report two patients with extensive NMSC treated by total body application of topical

  1. Total body calcium by neutron activation analysis. Reference data for children

    International Nuclear Information System (INIS)

    Ellis, K.J.; Shypailo, R.J.

    2001-01-01

    There is a paucity of data on the chemical composition of the human body during growth. Total body calcium (TBCa) has been reported for only one male child, aged 41/2 yr. TBCa values for 25 children and 27 young women using in vivo neutron activation analysis have been obtained. TBCa results were lower than those reported for the one male cadaver, as well as the estimates derived for the 'Reference Man' model. It was concluded that the reference values for TBCa may need to be adjusted to appropriately describe skeletal mineralization of contemporary children. (author)

  2. Treatment of neuroblastoma. Role of total Body Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Dini, G; Perin, G P; Franzone, P; Corvo, R; Scarpati, D

    1986-01-01

    Advanced neuroblastoma, scarcely responsive to conventional therapies, can take advantage of high dose chemio-radiotherapic treatment followed by bone marrow transplant. Nineteen young patients underwent an ablative chemotherapy with high dose Vincristine and Melphalan plus Total Body Irradiation in Genoa, Italy; all of them underwent autologus bone marrow transplantation. Fourteen children were in complete remission (CR), 5 had residual disease. Thirteen are alive after a median of 7 months following transplant; 9 are in CR; 4 have disease; 1 died for toxicity; 5 for relapse. The results seem to suggest that ablative therapy should be given to patients in CR. Toxicity was not remarkable mainly as far as TBI is concerned.

  3. Comparison of total body water determinations in lactating women by anthropometry, water displacement, and deuterium isotope dilution

    International Nuclear Information System (INIS)

    Wong, W.; Butte, N.; Lee, L.; Garza, C.; Klein, P.

    1986-01-01

    To expand the limited data on the total body water in lactating women, the authors have determined total body water contents, in eight subjects from anthropometric measurements, water displacement, and isotope dilution of deuterium oxide. On the day of the study, their skinfold thicknesses were measured over the biceps and triceps muscles and at the suprailiac and subscapular areas. Their body densities were measured by water displacement. Deuterium oxide was administered orally at 100 mg/kg of body weight. One predose milk sample was collected from each subject. The milk samples were defatted by centrifugation and the milk water was reduced to hydrogen gas for hydrogen isotope ratio measurements by gas-isotope-ratio mass spectrometry. The results indicated that total body water in lactating women estimated from anthropometric measurements was 49.7 +/- 3.3% of body weight, by water displacement was 54.9 +/- 7.2%, and by isotope dilution was 50.8 +/- 3.7%

  4. THE RELATIONSHIP BETWEEN DIABETES MELLITUS AND BODY MASS INDEX: PRIMARY CARE FACILITY IN PUERTO RICO.

    Science.gov (United States)

    Chavier-Roper, Rolance G; Alick-Ortiz, Sharlene; Davila-Plaza, Geraldine; Morales-Quiñones, Aixa G

    2014-01-01

    Obesity is a major risk factor in the development of Diabetes Mellitus (DM). Body Mass Index (BMI), an estimation based on the persons weight and height, helps identify patients at risk to develop DM. We report the relationship between DM and BMI using data from a primary care facility in Puerto Rico. Patients were chosen at random with the only requirement to be included in this study was age over 50. A population of 200 patients was obtained and each participant was categorized by gender, weight, height, BMI and their status as a known diabetic or not. In respect to the diabetic population identified, which totaled 67 patients, 1 out of 67 (1%) were underweight, 14 out of 67 (20%) were normal, 28 out of 67 (42%) were overweight, and 24 out of 67 (36%) obese. 78% of the diabetic population fell in the categories of either overweight or obese. BMI increases the incidence of Diabetes Mellitus in patients older than 50 years of age.

  5. Estimation of total body water by bioelectrical impedance analysis

    International Nuclear Information System (INIS)

    Kushner, R.F.; Schoeller, D.A.

    1986-01-01

    Total body water (TBW) measured by bioelectrical impedance analysis (BIA) was directly compared with deuterium-isotope dilution in a total of 58 subjects. First, sex-specific and group equations were developed by multiple regression analysis in (10 each) obese and nonobese men and women. Height/resistive impedance was the most significant variable used to predict deuterium-dilution space (D2O-TBW) and, combined with weight, yielded R = 0.99 and SE of estimate = 1.75 L. Equations predicted D2O-TBW equally well for obese and nonobese subjects. Second, the equations were prospectively tested in a heterogeneous group of 6 males and 12 females. Sex-specific equations predicted D2O-TBW with good correlation coefficients (0.96 and 0.93), total error (2.34 and 2.89 L), and a small difference between mean predicted and measured D2O-TBW (-1.4 +/- 2.05 and -0.48 +/- 2.83 L). BIA predicts D2O-TBW more accurately than weight, height, and/or age. A larger population is required to validate the applicability of our equations

  6. High-capacity neutron activation analysis facility

    International Nuclear Information System (INIS)

    Hochel, R.C.

    1979-01-01

    A high-capacity neutron activation analysis facility, the Reactor Activation Facility, was designed and built and has been in operation for about a year at one of the Savannah River Plant's production reactors. The facility determines uranium and about 19 other trace elements in hydrogeochemical samples collected in the National Uranium Resource Evaluation program. The facility has a demonstrated average analysis rate of over 10,000 samples per month, and a peak rate of over 16,000 samples per month. Uranium is determined by cyclic activation and delayed neutron counting of the U-235 fission products; other elements are determined from gamma-ray spectra recorded in subsequent irradiation, decay, and counting steps. The method relies on the absolute activation technique and is highly automated for round-the-clock unattended operation

  7. Measurement of the body content of sodium, potassium, chloride, calcium, phophorus and nitrogen with reference to spironolactone

    International Nuclear Information System (INIS)

    Boddy, K.

    1978-01-01

    The total body content of sodium, chloride, nitrogen, calcium and phosphorus can be measured simultaneously by in vivo activation analysis and at the same time total body potassium can be determined directly by whole body counting. These procedures have been described and compared with methods using isotope dilution. The complementary nature of the techniques, when properly applied, as well as reported disparities have been illustrated by a number of clinical investigations generally involving aldosterone antagonists. The methods should provide a better insight to the complex changes in body conposition and metabolism accociated with hypertension (and other diseases) and their treatment. (Auth.)

  8. Operating instructions for LBL radon measurement facilities

    International Nuclear Information System (INIS)

    Ingersoll, J.G.

    1980-06-01

    This manual is intended for users of the radon-measuring facilities of the Radon Project of the Building Ventilation and Indoor Air Quality Program at Lawrence Berkeley Laboratory. The manual comprises three parts. Part 1 sets out the steps involved in collecting, transferring, and counting radon. Part 2 describes the calibration of the transfer system and of the Lucas cells in the counting system. Part 3 outlines the maintenance procedures for the facility

  9. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    Energy Technology Data Exchange (ETDEWEB)

    Risco Norrlid, L. del (Swedish Radiation Safety Authority (Sweden)); Halldorsson, O. (Icelandic Radiation Safety Authority (Iceland)); Holm, S. (NM and PET at Copenhagen' s Univ. Hospital (Denmark)); Huikari, J. (Radiation and Nuclear Safety Authority (Finland)); Isaksson, M. (Goeteborg Univ., Dept. Radiation Physics Sahlgren Academy (Sweden)); Lind, B. (Norwegian Radiation Protection Authority (Norway)); Roed, H. (Danish State Institute for Radiation Protection (Denmark))

    2011-02-15

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  10. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    International Nuclear Information System (INIS)

    Risco Norrlid, L. del; Halldorsson, O.; Holm, S.; Huikari, J.; Isaksson, M.; Lind, B.; Roed, H.

    2011-02-01

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  11. Urea, creatinine, uric acid, and phosphate spaces and their relationship to total body water during chronic hemodialysis

    International Nuclear Information System (INIS)

    Ericsson, F.; Odar-Cederloef, I.E.; Eriksson, C.G.; Lindgren, S.; Kjellstrand, C.M.

    1988-01-01

    The authors determined total body water (TBW) with tritium in 11 patients on chronic hemodialysis and compared this space to that estimated by 60% of body weight, and removal spaces of urea, creatinine, uric acid, and phosphate (PO 4 ). The latter spaces were determined by dividing the total amount of substance (measured in total dialysate) by pre- minus post-dialysis concentrations. Body water X 0.6 was more than 10% less than the tritium space, and showed a maximal variation of 10 liters, or 24%. The removal space of urea was 80% of the tritium space, but correlated closely with it. The difference between total body water and urea removal space was variable and dependent on fluid excess (edema) in the patients. Creatinine, uric acid, and phosphate removal spaces were highly variable and not correlated to total body water. The authors suggest that actual measured TBW should be used, rather than estimations using BW X 0.6, for V in K X T/V, where K = clearance, T = duration of dialysis, and V = the removal space of urea. Furthermore, one may need to introduce a correction factor for urea removal space over TBW in the equation to allow better quantification of dialysis in edematous patients and during very fast dialyses

  12. Factor V Leiden is associated with increased sperm count

    NARCIS (Netherlands)

    van Mens, T. E.; Joensen, U. N.; Bochdanovits, Z.; Takizawa, A.; Peter, J.; Jørgensen, N.; Szecsi, P. B.; Meijers, J. C. M.; Weiler, H.; Rajpert-de Meyts, E.; Repping, S.; Middeldorp, S.

    2017-01-01

    STUDY QUESTION: Is the thrombophilia mutation factor V Leiden (FVL) associated with an increased total sperm count? SUMMARY ANSWER: Carriers of FVL have a higher total sperm count than non-FVL-carriers, which could not be explained by genetic linkage or by observations in a FVL-mouse model. WHAT IS

  13. Late effects on gonadal function of cyclophosphamide, total-body irradiation, and marrow transplantation

    International Nuclear Information System (INIS)

    Sanders, J.E.; Buckner, C.D.; Leonard, J.M.; Sullivan, K.M.; Witherspoon, R.P.; Deeg, H.J.; Storb, R.; Thomas, E.D.

    1983-01-01

    One hundred thirty-seven patients had gonadal function evaluated 1-11 years after marrow transplantation. All 15 women less than age 26 and three of nine older than age 26 who were treated with 200 mg/kg cyclophosphamide recovered normal gonadotropin levels and menstruation. Five have had five pregnancies resulting in three live births, one spontaneous abortion, and one elective abortion. Three of 38 women who were prepared with 120 mg/kg cyclophosphamide and 920-1200 rad total-body irradiation had normal gonadotropin levels and menstruation. Two had pregnancies resulting in one spontaneous and one elective abortion. Of 31 men prepared with 200 mg/kg cyclophosphamide, 30 had normal luteinizing hormone levels, 20 had normal follicle-stimulating hormone levels, and 10 of 15 had spermatogenesis. Four have fathered five normal children. Thirty-six of 41 men prepared with 120 mg/kg cyclophosphamide and 920-1750 rad total-body irradiation had normal luteinizing hormone levels, ten had normal follicle-stimulating hormone levels, and 2 of 32 studied had spermatogenesis. One has fathered two normal children. It was concluded that cyclophosphamide does not prevent return of normal gonadal function in younger women and in most men. Total-body irradiation prevents return of normal gonadal function in the majority of patients

  14. Optimum combination of targeted 131I and total body irradiation for treatment of disseminated cancer

    International Nuclear Information System (INIS)

    Amin, Amin E.; Wheldon, Tom E.; O'Donoghue, Joseph A.; Gaze, Mark N.; Barrett, Ann

    1995-01-01

    Purpose: Radiobiological modeling was used to explore optimum combination strategies for treatment of disseminated malignancies of differing radiosensitivity and differing patterns of metastatic spread. The purpose of the study was to derive robust conclusions about the design of combination strategies that incorporate a targeting component. Preliminary clinical experience of a neuroblastoma treatment strategy, which is based upon general principles obtained from modelling, is briefly described. Methods and Materials: The radiobiological analysis was based on an extended (dose-rate dependent) formulation of the linear quadratic model. Radiation dose and dose rate for targeted irradiation of tumors of differing size was in part based on microdosimetric considerations. The analysis was applied to several tumor types with postulated differences in the pattern of metastatic spread, represented by the steepness of the slope of the relationship between numbers of tumors present and tumor diameter. The clinical pilot study entailed the treatment of five children with advanced neuroblastoma using a combination of 131 I metaiodobenzylguanidine (mIBG) and total body irradiation followed by bone marrow rescue. Results: The theoretical analysis shows that both intrinsic radiosensitivity and pattern of metastatic spread can influence the composition of the ideal optimum combination strategy. High intrinsic radiosensitivity generally favors a high proportion of targeting component in the combination treatment, while a strong tendency to micrometastatic spread favors a major contribution by total body irradiation. The neuroblastoma patients were treated using a combination regimen with an initially low targeting component (2 Gy whole body dose from targeting component plus 12 Gy from total body irradiation). The treatment was tolerable and resulted in remissions in excess of 9 months in each of these advanced neuroblastoma patients. Conclusions: Radiobiological analysis, which

  15. Maximum entropy deconvolution of low count nuclear medicine images

    International Nuclear Information System (INIS)

    McGrath, D.M.

    1998-12-01

    Maximum entropy is applied to the problem of deconvolving nuclear medicine images, with special consideration for very low count data. The physics of the formation of scintigraphic images is described, illustrating the phenomena which degrade planar estimates of the tracer distribution. Various techniques which are used to restore these images are reviewed, outlining the relative merits of each. The development and theoretical justification of maximum entropy as an image processing technique is discussed. Maximum entropy is then applied to the problem of planar deconvolution, highlighting the question of the choice of error parameters for low count data. A novel iterative version of the algorithm is suggested which allows the errors to be estimated from the predicted Poisson mean values. This method is shown to produce the exact results predicted by combining Poisson statistics and a Bayesian interpretation of the maximum entropy approach. A facility for total count preservation has also been incorporated, leading to improved quantification. In order to evaluate this iterative maximum entropy technique, two comparable methods, Wiener filtering and a novel Bayesian maximum likelihood expectation maximisation technique, were implemented. The comparison of results obtained indicated that this maximum entropy approach may produce equivalent or better measures of image quality than the compared methods, depending upon the accuracy of the system model used. The novel Bayesian maximum likelihood expectation maximisation technique was shown to be preferable over many existing maximum a posteriori methods due to its simplicity of implementation. A single parameter is required to define the Bayesian prior, which suppresses noise in the solution and may reduce the processing time substantially. Finally, maximum entropy deconvolution was applied as a pre-processing step in single photon emission computed tomography reconstruction of low count data. Higher contrast results were

  16. Measurement of neutron total cross-sections for {sup nat}Dy at Pohang Neutron Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S. G.; Kye, Y. U.; Shvetsov, Valery; Cho, M. H. [POSTECH, Pohang (Korea, Republic of); Namkung, W.; Cho, M. H. [Pohang Accelerator Laboratory, Pohang (Korea, Republic of); Kim, G. N. [Kyungpook National Univ., Daegu (Korea, Republic of); Lee, M. W. [Dongnam Inst. of radiological and Medical Science, Busan (Korea, Republic of)

    2013-05-15

    There are few measurements for Dy below 100 eV. Moreover, there exist discrepancies among the measurements. In the present work, the total neutron cross-sections for {sup nat}Dy were measured by using the time-of-flight (TOF) method at the Pohang Neutron Facility (PNF). The PNF consists of an electron linac, a water-cooled Ta target, and an 11-m-long TOF path. The characteristics of PNF are described elsewhere. We also briefly discuss the future plan to verify our experimental result. We have measured the total neutron cross-sections of {sup nat}Dy in the neutron energy region from 0.1 eV to 100 eV with the TOF method at the Po hang Neutron Facility. The present result is in good agreement with the previous data and the evaluated data in ENDF/B-VI. We would like to get resonance parameters by using SAMMY or REFIT codes.

  17. The use of bioelectrical impedance analysis to estimate total body water in young children with cerebral palsy.

    Science.gov (United States)

    Bell, Kristie L; Boyd, Roslyn N; Walker, Jacqueline L; Stevenson, Richard D; Davies, Peter S W

    2013-08-01

    Body composition assessment is an essential component of nutritional evaluation in children with cerebral palsy. This study aimed to validate bioelectrical impedance to estimate total body water in young children with cerebral palsy and determine best electrode placement in unilateral impairment. 55 young children with cerebral palsy across all functional ability levels were included. Height/length was measured or estimated from knee height. Total body water was estimated using a Bodystat 1500MDD and three equations, and measured using the gold standard, deuterium dilution technique. Comparisons were made using Bland Altman analysis. For children with bilateral impairment, the Fjeld equation estimated total body water with the least bias (limits of agreement): 0.0 L (-1.4 L to 1.5 L); the Pencharz equation produced the greatest: 2.7 L (0.6 L-4.8 L). For children with unilateral impairment, differences between measured and estimated total body water were lowest on the unimpaired side using the Fjeld equation 0.1 L (-1.5 L to 1.6 L)) and greatest for the Pencharz equation. The ability of bioelectrical impedance to estimate total body water depends on the equation chosen. The Fjeld equation was the most accurate for the group, however, individual results varied by up to 18%. A population specific equation was developed and may enhance the accuracy of estimates. Australian New Zealand Clinical Trials Registry (ANZCTR) number: ACTRN12611000616976. Copyright © 2012 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  18. Total body irradiation

    International Nuclear Information System (INIS)

    Barrett, A.

    1988-01-01

    This paper describes body irradiation (TBI) being used increasingly as consolidation treatment in the management of leukaemia, lymphoma and various childhood tumours with the aim of sterilizing any malignant cells or micrometastases. Systemic radiotherapy as an adjunct to chemotherapy offers several possible benefits. There are no sanctuary sites for TBI; some neoplastic cells are very radiosensitive, and resistance to radiation appears to develop less readily than to drugs. Cross-resistance between chemotherapy and radiotherapy does not seem to be common and although plateau effects may be seen with chemotherapy there is a linear dose-response curve for clonogenic cell kill with radiation

  19. Measurement of body potassium with a whole-body counter: relationship between lean body mass and resting energy expenditure

    International Nuclear Information System (INIS)

    Jensen, M.D.; Braun, J.S.; Vetter, R.J.; Marsh, H.M.

    1988-01-01

    We conducted studies to determine whether the Mayo whole-body counter could be used to measure body potassium, and thus lean body mass (LBM), and whether moderate obesity alters resting energy expenditure when corrected for LBM. Twenty-four nonobese and 18 moderately obese adults underwent body potassium (40K) counting, as well as tritiated water space measurement and indirect calorimetry. LBM values predicted from 40K counting and tritiated water space measurements were highly correlated (P = 0.001; r = 0.88). Resting energy expenditure was closely related to LBM (P less than 0.0001; r = 0.78): kcal/day = 622 kcal + (LBM.20.0 kcal/kg LBM). In this relationship, the obese subjects did not differ from nonobese subjects. In summary, the Mayo whole-body counter can accurately measure LBM, and moderate obesity has no detectable effect on corrected resting energy expenditure

  20. Radioprotection of liver lipids of whole-body gamma-irradiated female rats by cystamine

    International Nuclear Information System (INIS)

    Ramanathan, R.; Misra, U.K.

    1976-01-01

    The effect of administration of cystamine (5 mg/100 g body weight) before 1,200 R whole-body gamma irradiation has been studied on irradiation-induced changes in liver and its subcellular fractions'lipids of fasted female rats. Cystamine prevented the irradiation-induced increase in liver triglycerides and liver mitochondrial total phospholipids, but it decreased microsomal total phospholipids and proteins. Cystamine prevented the radiation-induced increased 32 P-radioactivity (counts/min/μmole phospholipid phosphorus) of microsomal phosphatidyl choline. Cystamine prevented the radiation-induced increased uptake of NaH 2 32 PO 4 (counts/min/g liver) in liver microsomal phosphatidyl ethanolamine and supernatant phosphatidyl choline; but in microsomal phosphatidyl choline, cystamine did not do so, but on the other hand it itself increased the uptake in control rats. Cystamine did not prevent the irradiation-induced decreased incorporation of (U- 14 C)glucose into liver triglycerides, total phospholipids and phosphatidyl choline. Cystamine itself decreased the incorporation of (U- 14 C)glucose into liver triglycerides and phosphoglycerides of control rats. (orig.) [de

  1. Chemical Hygiene Plan for Onsite Measurement and Sample Shipping Facility Activities

    International Nuclear Information System (INIS)

    Price, W.H.

    1998-01-01

    This chemical hygiene plan presents the requirements established to ensure the protection of employee health while performing work in mobile laboratories, the sample shipping facility, and at the onsite radiological counting facility. This document presents the measures to be taken to promote safe work practices and to minimize worker exposure to hazardous chemicals. Specific hazardous chemicals present in the mobile laboratories, the sample shipping facility, and in the radiological counting facility are presented in Appendices A through G

  2. Evaluation of nuclear magnetic resonance spectroscopy for determination of deuterium abundance in body fluids: application to measurement of total-body water in human infants

    International Nuclear Information System (INIS)

    Rebouche, C.J.; Pearson, G.A.; Serfass, R.E.; Roth, C.W.; Finley, J.W.

    1987-01-01

    Nuclear magnetic resonance (NMR) spectroscopy was used to quantitate abundance of 2H in body water of human infants. This method provides precise measurement of total-body water without the extensive sample preparation requirements of previously described methods for determination of 2H content in body fluids. 2H2O (1 g/kg body weight) was administered to infants and saliva and urine were collected for up to 5 h. An internal standard was added directly to the fluid specimen and 2H enrichment in water was measured by NMR spectroscopy. Working range of deuterium abundance was 0.04-0.32 atom %. Coefficients of variation for saliva samples at 0.20 atom % 2H was 1.97%. 2H content in urine and saliva water reached a plateau by 4 h after administration, and amounts in the two fluids were virtually identical. Mean total-body water determination for six infants was 58.3 +/- 5.8% of body weight (range 53-66%)

  3. Studies on iron absorption and retention in malnourished Indian subjects, using Fe-59 and whole-body counting

    International Nuclear Information System (INIS)

    Gopalan, C.; Srikantia, S.G.

    1975-12-01

    The gastrointestinal absorption of iron under various conditions in representatives of the Indian population, and several related matters, have been investigated. Percentage absorption was determined by whole-body counting of 59Fe, or by measuring the concentration of 55Fe in the blood, at about two weeks after administration of the respective tracer. It was confirmed or established that: (1) food or supplemental iron, if available at all, tends to be absorbed from the intestines as if present there in one of two alternative pools: heme and non heme; (2) 30%-50% of iron measured chemically in Indian foods appears to be in an unavailable form, for example as a contaminant in adventitiously present dust; (3) fortification of the diet with iron may be feasible by adding FePO 4 + 2 molar NaHSO 4 to common salt under suitable conditions; (4) monkeys appear to be sufficiently similar to humans in their iron absorption characteristics that they may be the best available non-human model for preliminary experimental investigations of iron absorption; and (5) a promising preparative method for liquid scintillation counting of 55Fe present in blood is to extract it into toluene in the presence of di (2-ethyl-hexyl) phosphate (HDEHP)

  4. Design and characteristics of a 4 MV total body irradiator

    International Nuclear Information System (INIS)

    Lutz, W.R.; Chin, L.M.

    1988-01-01

    A facility for total body X-ray irradiation (TBI) has been built using two 4 MV linear accelerators, one mounted under the ceiling, the other in a floor-pit. The distance between the two sources is 410 cm to produce a field size of 200 cm x 75 cm in the midplane. This field covers the patient, lying supine on a stretcher halfway between the sources. Components from commercially available accelerators were used. Special beam hardening and flattening filters were built to achieve acceptable dose profiles in the large field. The primary collimator was modified to produce a 235 cm x 92 cm field at 205 cm from the source, while movable focused collimators were designed to define fields up to 220 cm x 80 cm. Because of the wide beams, large rectangular parallel-plate ionization chambers were built to serve as beam monitors. The dose rate at 205 cm distance from the sources can be set between 5 and 80 cGy/min, each machine contributing half. The dosimetric characteristics are practically the same for both units. The per cent depth dose for the TBI beams is 76% at a source-surface distance of 195 cm. The half value layer decreases by 12% from the centre to near the edge of the beam. Owing to the large field size, the surface dose for the TBI beams is about 80% of the dose at 1 cm depth. The dose delivery has been verified to be within 2% of the calculated value at the reference point in a homogeneous water humanoid phantom. Measurements indicate that lung doses can be predicted by the ratio-of-TMR (tissue-to-maximum ratio) method with acceptable accuracy. Lead sheets are used as attenuators to prevent excessive lung doses. (author). 7 refs, 7 figs

  5. In vivo neutron activation at the Sloan-Kettering Institute

    International Nuclear Information System (INIS)

    Bigler, R.E.

    1986-01-01

    A medical cyclotron (Model CS-15, The Cyclotron Corporation, Berkeley, CA) with a multi-layer neutron collimator designed for partial body neutron irradiations and a low-background patient counting facility have been established for measurement of bone calcium and sodium; and soft tissue, exchangeable sodium and chlorine. The cyclotron also provides total-body calcium by the 37 Ar method of Palmer. (author)

  6. Total Body Capacitance for Estimating Human Basal Metabolic Rate in an Egyptian Population

    Science.gov (United States)

    M. Abdel-Mageed, Samir; I. Mohamed, Ehab

    2016-01-01

    Determining basal metabolic rate (BMR) is important for estimating total energy needs in the human being yet, concerns have been raised regarding the suitability of sex-specific equations based on age and weight for its calculation on an individual or population basis. It has been shown that body cell mass (BCM) is the body compartment responsible for BMR. The objectives of this study were to investigate the relationship between total body capacitance (TBC), which is considered as an expression for BCM, and BMR and to develop a formula for calculating BMR in comparison with widely used equations. Fifty healthy nonsmoking male volunteers [mean age (± SD): 24.93 ± 4.15 year and body mass index (BMI): 25.63 ± 3.59 kg/m2] and an equal number of healthy nonsmoking females matched for age and BMI were recruited for the study. TBC and BMR were measured for all participants using octopolar bioelectric impedance analysis and indirect calorimetry techniques, respectively. A significant regressing equation based on the covariates: sex, weight, and TBC for estimating BMR was derived (R=0.96, SEE=48.59 kcal, and P<0.0001), which will be useful for nutritional and health status assessment for both individuals and populations. PMID:27127453

  7. Effect of BCNU combined with total body irradiation or cyclophosphamide on survival of dogs after autologous marrow grafts

    International Nuclear Information System (INIS)

    Paterson, A.H.G.; English, D.

    1979-01-01

    Dogs were treated with either: (1) 750 rad total body irradiation; (2) BCNU 2 or 4 mg/kg IV 48 hours prior to 750 rad total body irradiation; or (3) BCNU 4 mg/kg IV plus cyclophosphamide 30 mg/kg IV. Results showed that of 11 dogs who received 750 rad total body irradiation and did not receive cryopreserved autologous bone marrow cells, none survived, compared to an 88% survival (31 of 35 dogs) after 750 rad total body irradiation if the dogs received stored autologous bone marrow cells. However, when the dogs were treated with BCNU 2 or 4 mg/kg prior to 750 rad total body irradiation the survival rate, despite infusion of autologous bone marrow cells, dropped to 25% (3 of 12 dogs) for BCNU 2 mg/kg, and 17% (2 of 12 dogs) for BCNU 4 mg/kg. This effect did not seem to be due to direct serum inhibition of hemopoietic cell proliferation since serum obtained at various intervals after BCNU administrations failed to inhibit CFU growth in vitro. The dogs died from hemorrhage and infection; at autopsy there was hemorrhagic pneumonitis and intestinal ulcerations with petechial hemorrhages, suggesting that the combination of BCNU and total body irradiation may have synergistic toxicity on the canine gastro-intestinal tract. When BCNU was combined with cyclophosphamide, reversal of marrow toxicity occurred in 54% (6 of 11 dogs) with stored autologous bone marrow cells compared to no survival (0 of 8 dogs) with stored autologous bone marrow cells. Thus while autologous bone marrow grafts are useful for reversal of marrow toxicity due to many therapeutic protocols, such grafts alone may not provide protection against toxicity due to the combination of high dosage BCNU and total body irradiation

  8. MRI estimation of total renal volume demonstrates significant association with healthy donor weight

    International Nuclear Information System (INIS)

    Cohen, Emil I.; Kelly, Sarah A.; Edye, Michael; Mitty, Harold A.; Bromberg, Jonathan S.

    2009-01-01

    Purpose: The purpose of this study was to correlate total renal volume (TRV) calculations, obtained through the voxel-count method and ellipsoid formula with various physical characteristics. Materials and methods: MRI reports and physical examination from 210 healthy kidney donors (420 kidneys), on whom renal volumes were obtained using the voxel-count method, were retrospectively reviewed. These values along with ones obtained through a more traditional method (ellipsoid formula) were correlated with subject height, body weight, body mass index (BMI), and age. Results: TRV correlated strongly with body weight (r = 0.7) and to a lesser degree with height, age, or BMI (r = 0.5, -0.2, 0.3, respectively). The left kidney volume was greater than the right, on average (p < 0.001). The ellipsoid formula method over-estimated renal volume by 17% on average which was significant (p < 0.001). Conclusions: Body weight was the physical characteristic which demonstrated the strongest correlation with renal volume in healthy subjects. Given this finding, a formula was derived for estimating the TRV for a given patient based on the his or her weight: TRV = 2.96 x weight (kg) + 113 ± 64.

  9. The relationship of total body composition with bone mineral density in postmenopausal women with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Vadim Valer'evich Klimontov

    2015-03-01

    Full Text Available AimTo determine the relationship between bone mineral density (BMD and total body composition in postmenopausal women with type 2 diabetes.Materials and MethodsThe study included 78 women, from 50 to 70 years of age (median 63 years. Twenty women had normal body mass index (BMI, 29 ones were overweight and 29 had obesity. The body composition and BMD was studied by dual-energy X-ray absorptiometry.ResultsWomen with normal BMD had higher BMI, total and truncal fat mass, as well lean mass as compared to women with osteoporosis and osteopenia (all p <0.05. Patients with osteoporosis had a lower fat mass at the hips, compared with those with normal BMD. Total and truncal fat mass, as well as lean mass were positively correlated with BMD in the lumbar spine and proximal femur, femoral neck and radius. In multivariate regression analysis fat mass was an independent predictor for total BMD, after adjusting for age, BMI, duration of menopause, HbA1c, glomerular filtration rate and other total body composition parameters.ConclusionsIn postmenopausal type 2 diabetic women BMI and fat mass is associated positively with BMD.

  10. IMPACT OF 10 SESSIONS OF WHOLE BODY CRYOSTIMULATION ON AEROBIC AND ANAEROBIC CAPACITY AND ON SELECTED BLOOD COUNT PARAMETERS

    Directory of Open Access Journals (Sweden)

    Tomasz Dybek

    2012-01-01

    Full Text Available The systemic effect of low temperature suggests that sessions in a cryogenic chamber might improve athletes’ capacity as a standard element of training. Therefore the authors decided to evaluate the impact of 10 sessions of whole body cryostimulation (WBCT on aerobic and anaerobic efficiency as well as on selected blood count parameters. The study group included 32 volunteers – 16 women and 16 men. The volunteers underwent 10 sessions of WBCT in a cryogenic chamber. Blood samples (RBC, WBC, PLT, HGB, HCT were taken, and aerobic and anaerobic efficiency and lactate concentration in capillary blood were measured before the first session and one day after the last one. No significant differences were observed in values of aerobic capacity after 10 sessions of WBCT. There was a rising trend in men and a declining trend in women. The lactate concentration did not differ significantly before and after WBCT. A slight rise in aerobic and anaerobic threshold was observed in men, while in women the values slightly fell. The Wingate test showed no significant differences in results before and after cryostimulation. Only the TOBT was significantly shorter in men (6.12±1.49 vs 3.79±1.14 s. The WBCT sessions resulted in a significant rise of the haematological parameters both in women and men, excluding HCT, which showed a statistically insignificant rise. Ten sessions of whole body cryostimulation did not affect aerobic or anaerobic capacity in the tested group, although it improved the blood count parameters.

  11. Radiation nephritis following total-body irradiation and cyclophosphamide in preparation for bone marrow transplantation

    International Nuclear Information System (INIS)

    Bergstein, J.; Andreoli, S.P.; Provisor, A.J.; Yum, M.

    1986-01-01

    Two children prepared for bone marrow transplantation with total-body irradiation and cyclophosphamide developed hypertension, microscopic hematuria, proteinuria, diminished renal function, and anemia six months after transplantation. Light microscopy of the kidneys revealed mesangial expansion, glomerular capillary wall thickening, and lumenal thrombosis. Electron microscopy demonstrated widening of the subendothelial space due to the deposition of amorphous fluffy material. In one patient, immunofluorescence microscopy revealed glomerular capillary wall deposition of fibrin and immunoglobulins. The clinical and histologic findings support the diagnosis of radiation nephritis. Patients prepared for bone marrow transplantation with total-body irradiation and cyclophosphamide should be followed closely after transplantation for the development of hypertension, proteinuria, and renal insufficiency

  12. Scaling up antiretroviral treatment services in Karnataka, India: impact on CD4 counts of HIV-infected people.

    Directory of Open Access Journals (Sweden)

    Suresh Shastri

    Full Text Available SETTING: Twelve antiretroviral treatment centres under National AIDS Control Programme (NACP, Karnataka State, India. OBJECTIVE: For the period 2004-2011, to describe the trends in the numbers of people living with HIV (PLHIV registered for care and their median baseline CD4 counts, disaggregated by age and sex. DESIGN: Descriptive study involving analysis of routinely captured data (year of registration, age, sex, baseline CD4 count under NACP. RESULTS: 34,882 (97% of total eligible PLHIV were included in analysis. The number registered for care has increased by over 12 times during 2004-11; with increasing numbers among females. The median baseline CD4 cell count rose from 125 in 2004 to 235 in 2011--the increase was greater among females as compared to males. However, about two-thirds still presented at CD4 cell counts less than 350. CONCLUSION: We found an increasing trend of median CD4 counts among PLHIV presenting to ART centres in Karnataka, an indicator of enhanced and early access to HIV care. Equal proportion of females and higher baseline CD4 counts among them allays any fear of differential access by gender. Despite this relative success, a substantial proportion still presented at low CD4 cell counts indicating possibly delayed HIV diagnosis and delayed linkage to HIV care. Universal HIV testing at health care facilities and strengthening early access to care are required to bridge the gap.

  13. Measurement of total body calcium in osteoporotic patients treated with salmon calcitonin

    International Nuclear Information System (INIS)

    Zanzi, I.; Thompson, K.; Cohn, S.H.

    1981-01-01

    In the past, the evaluation of therapies for osteoporosis has been limited by the lack of a suitable quantitative end point. The introduction of the technique of in vivo total body neutron activation analysis (TBNAA) has made possible the precise and accurate measurement of total body calcium (TBCa). Since almost 99 percent of TBCa is in the skeleton, TBNAA gives a direct measurement of skeletal mass. Thus, changes in skeletal mass serve as an objective criterion in the evaluation of the efficacy of the therapy in osteoporosis. Studies performed at Brookhaven National Laboratory and elsewhere have reported the use of calcitonin (CT) in the treatment of primary osteoporosis and related conditions in a limited number of patients. The physiological effects of CT as an inhibitor of bone resorption has been the rationale of its use. The results of a randomized, controlled, 2 year therapeutical trial of CT in a group of postmenopausal osteoporotic women are presented in this report

  14. Set of counts by scintillations for atmospheric samplings

    International Nuclear Information System (INIS)

    Appriou, D.; Doury, A.

    1962-01-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies

  15. Investigation on Carbohydrate Counting Method in Type 1 Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Osman Son

    2014-01-01

    Full Text Available Objective. The results from Diabetes Control and Complications Trial (DCCT have propounded the importance of the approach of treatment by medical nutrition when treating diabetes mellitus (DM. During this study, we tried to inquire carbohydrate (Kh count method’s positive effects on the type 1 DM treatment’s success as well as on the life quality of the patients. Methods. 22 of 37 type 1 DM patients who applied to Eskişehir Osmangazi University, Faculty of Medicine Hospital, Department of Endocrinology and Metabolism, had been treated by Kh count method and 15 of them are treated by multiple dosage intensive insulin treatment with applying standard diabetic diet as a control group and both of groups were under close follow-up for 6 months. Required approval was taken from the Ethical Committee of Eskişehir Osmangazi University, Medical Faculty, as well as informed consent from the patients. The body weight of patients who are treated by carbohydrate count method and multiple dosage intensive insulin treatment during the study beginning and after 6-month term, body mass index, and body compositions are analyzed. A short life quality and medical research survey applied. At statistical analysis, t-test, chi-squared test, and Mann-Whitney U test were used. Results. There had been no significant change determined at glycemic control indicators between the Kh counting group and the standard diabetic diet and multiple dosage insulin treatment group in our study. Conclusion. As a result, Kh counting method which offers a flexible nutrition plan to diabetic individuals is a functional method.

  16. Control system considerations for the AHF [Advanced Hadron Facility

    International Nuclear Information System (INIS)

    Butler, H.S.

    1989-01-01

    This paper identifies some of the more important issues related to the design of a control system for the Advanced Hadron Facility (AHF). It begins with a brief description of the site layout and how the various accelerators operate in tandem to deliver beam to several experimental areas. Then it focuses on the control system by estimating from existing installations the number of data and control channels to be expected for the AHF. The total comes to 50,000. This channel count is converted to manpower and cost estimates for the control system by extrapolating from other accelerator facilities. Finally, special attention is given to two subsystems -- magnets and diagnostic equipment -- and the impact they will have on the control system. 11 refs., 5 figs., 6 tabs

  17. Abdominal Obesity and their association with Total Body: Fat Distribution and Composition. Case of Algerian Teenager Male high school students

    Directory of Open Access Journals (Sweden)

    Mohammed Zerf

    2017-06-01

    Full Text Available Purpose: Our aim attempted to esteem the impact of abdominal fat on body fat distribution or composition related to total body fat as recommended weight loss among High School Students. Material: For the proposed, 100 male students from the Algerian high school Education Sector's mandate Sidi Bel Abbes, participate in the present study. Their average age 16±1.52 years, distributed into homogeneous groups, according to their body fat percent categories. Examined by saving tests (Body Fat Percentage (BFP - Abdominal circumference (WC - Body mass index (BMI. Results: Based on the test data and the analysis statistics applied, we confirm: a Abdominal obesity is excess body gain correlate with total fat BMI. It highly affected body composition reported as additional fat for overweight in compare with acceptable according to Ideal BFP categories. b Abdominal obesity is an amount deep fat correlates to total BFP. It higher influenced the distribution of total body fat reported as additional excess fat among overweight category compared to the acceptable group. c Waist circumference (WC is the leading marker of abdominal fat deposits located in the central region of the body. While the combination of body mass index (BMI and waist circumference (WC, reflects the combined effects of body build (fat or fatness in individuals at higher risk of excessive body fat. Conclusions: founded on the differences acquired by the research team. We highlight that abdominal obesity is strongly connected to larger WC relate to total body gain located as excess inordinate fatness BMI or fat distribution BFP among our overall sample. Evidence, which guides us to recommend our adolescent students to intensification their hours of sports practice, in order to avoid the consequences of abdominal obesity gain. Announced in the present study as excess abdominal adiposity more metabolically active. Requiring the control of body weight loss (BFP or BMI strongly correlates to

  18. Skeletal and total body volumes of human fetuses: assessment of reference data by spiral CT

    International Nuclear Information System (INIS)

    Braillon, Pierre M.; Buenerd, Annie; Bouvier, Raymonde; Lapillonne, Alexandre

    2002-01-01

    Objective: To define reference data for skeletal and total body volumes of normal human fetuses. Materials and methods: Spiral CT was used to assess the skeletal and total body volumes of 31 normal human stillborn infants with gestational age (GA) and body weight (BW) ranging from 14 to 41.5 weeks and 22 to 3,760 g, respectively. CT scans (slice thickness 2.7 mm, pitch 0.7) were performed within the first 24 h after delivery. Precise bone and soft-tissue windows were defined from analysis of the density along the diaphysis of the fetal long bones and from the measurement of a phantom that mimics soft tissues. Lengths and volumes were obtained from 3D reconstructions. The femur lengths measured from CT images (FLct) were compared with those provided by US studies (FLus). Results: Significant correlations (r>0.9) were found between BW, measured volumes of the entire skeleton or head, long-bone lengths, biparietal diameter and GA. Strong linear correlations (r>0.98) were observed between FLct and FLus. Conclusions: Skeletal and total body volume values obtained using spiral CT were significantly correlated with fetal biometric measurements. These data could complement those obtained in obstetric investigations with US. (orig.)

  19. Airborne microbial composition in a high-throughput poultry slaughtering facility.

    Science.gov (United States)

    Liang, Ruiping; Tian, Jijing; She, Ruiping; Meng, Hua; Xiao, Peng; Chang, Lingling

    2013-03-01

    A high-throughput chicken slaughtering facility in Beijing was systematically investigated for numbers of airborne microorganisms. Samples were assessed for counts of aerobic bacteria, Staphylococcus aureus, total coliforms, Escherichia coli, Pseudomonas aeruginosa, Listeria monocytogenes, Bacillus cereus, and Salmonella. During a 4-month period (September to December 2011), samples were collected for 10 min three times daily (preproduction, production, and postproduction). Samples were collected for three consecutive days of each month with an FA-1 sampler from six sampling sites: receiving-hanging, soaking-scalding and defeathering, evisceration, precooling, subdividing, and packing. Humidity, temperature, wind velocity, and airborne particulates also were recorded at each sampling site and time. The highest counts of microorganisms were recorded in the initial stages of processing, i.e., the receiving-hanging and defeathering areas, with a definite decline toward the evisceration, prechilling, subdividing, and packing areas; the prechilling area had the lowest microbial counts of 2.4 × 10(3) CFU/m(3). Mean total coliforms counts ranged from 8.4 × 10(3) to 140 CFU/m(3). Maximum E. coli counts were 6.1 × 10(3) CFU/m(3) in the soaking-scalding and defeathering area. B. cereus, P. aeruginosa, and S. aureus represented only a small proportion of the microbial population (1,900 to 20 CFU/m(3)). L. monocytogenes and Salmonella were rarely detected in evisceration, precooling, subdividing, and packing areas. Our study identified the levels of bioaerosols that may affect chicken product quality. This finding could be useful for improved control of microbial contamination to ensure product quality.

  20. High-capacity neutron activation analysis facility

    International Nuclear Information System (INIS)

    Hochel, R.C.; Bowman, W.W.; Zeh, C.W.

    1980-01-01

    A high-capacity neutron activation analysis facility, the Reactor Activation Facility, was designed and built and has been in operation for about a year at one of the Savannah River Plant's production reactors. The facility determines uranium and about 19 other elements in hydrogeochemical samples collected in the National Uranium Resource Evaluation program, which is sponsored and funded by the United States Department of Energy, Grand Junction Office. The facility has a demonstrated average analysis rate of over 10,000 samples per month, and a peak rate of over 16,000 samples per month. Uranium is determined by cyclic activation and delayed neutron counting of the U-235 fission products; other elements are determined from gamma-ray spectra recorded in subsequent irradiation, decay, and counting steps. The method relies on the absolute activation technique and is highly automated for round-the-clock unattended operation

  1. Bioimpedance index for measurement of total body water in severely malnourished children

    DEFF Research Database (Denmark)

    Girma, Tsinuel; Kæstel, Pernille; Workeneh, Netsanet

    2016-01-01

    BACKGROUND & OBJECTIVES: Restoration of body composition indicates successful management of severe acute malnutrition (SAM). Bioimpedance (BI) index (height(2)/resistance) is used to predict total body water (TBW) but its performance in SAM, especially with oedema, requires further investigation....... SUBJECTS/METHODS: Children with SAM (mid-arm circumference ...Hzs. Pre- and post-deuterium dose saliva samples were analysed using isotope-ratio mass spectrometry. TBW was regressed on H(2)/Z. Xc and R were height (H)-indexed, and Xc/H plotted against R/H. RESULTS: Thirty five children (16 non-oedematous and 19 oedematous) with median (interquartile range) age of 42...

  2. Hybrid Wing Body Aircraft Acoustic Test Preparations and Facility Upgrades

    Science.gov (United States)

    Heath, Stephanie L.; Brooks, Thomas F.; Hutcheson, Florence V.; Doty, Michael J.; Haskin, Henry H.; Spalt, Taylor B.; Bahr, Christopher J.; Burley, Casey L.; Bartram, Scott M.; Humphreys, William M.; hide

    2013-01-01

    NASA is investigating the potential of acoustic shielding as a means to reduce the noise footprint at airport communities. A subsonic transport aircraft and Langley's 14- by 22-foot Subsonic Wind Tunnel were chosen to test the proposed "low noise" technology. The present experiment studies the basic components of propulsion-airframe shielding in a representative flow regime. To this end, a 5.8-percent scale hybrid wing body model was built with dual state-of-the-art engine noise simulators. The results will provide benchmark shielding data and key hybrid wing body aircraft noise data. The test matrix for the experiment contains both aerodynamic and acoustic test configurations, broadband turbomachinery and hot jet engine noise simulators, and various airframe configurations which include landing gear, cruise and drooped wing leading edges, trailing edge elevons and vertical tail options. To aid in this study, two major facility upgrades have occurred. First, a propane delivery system has been installed to provide the acoustic characteristics with realistic temperature conditions for a hot gas engine; and second, a traversing microphone array and side towers have been added to gain full spectral and directivity noise characteristics.

  3. SU-E-T-540: Volumetric Modulated Total Body Irradiation Using a Rotational Lazy Susan-Like Immobilization System

    International Nuclear Information System (INIS)

    Gu, X; Hrycushko, B; Lee, H; Lamphier, R; Jiang, S; Abdulrahman, R; Timmerman, R

    2014-01-01

    Purpose: Traditional extended SSD total body irradiation (TBI) techniques can be problematic in terms of patient comfort and/or dose uniformity. This work aims to develop a comfortable TBI technique that achieves a uniform dose distribution to the total body while reducing the dose to organs at risk for complications. Methods: To maximize patient comfort, a lazy Susan-like couch top immobilization system which rotates about a pivot point was developed. During CT simulation, a patient is immobilized by a Vac-Lok bag within the body frame. The patient is scanned head-first and then feet-first following 180° rotation of the frame. The two scans are imported into the Pinnacle treatment planning system and concatenated to give a full-body CT dataset. Treatment planning matches multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. VMAT fields of the torso are optimized to satisfy lung dose constraints while achieving a therapeutic dose to the torso. The multiple isocenter VMAT fields are delivered with an indexed couch, followed by body frame rotation about the pivot point to treat the lower body isocenters. The treatment workflow was simulated with a Rando phantom, and the plan was mapped to a solid water slab phantom for point- and film-dose measurements at multiple locations. Results: The treatment plan of 12Gy over 8 fractions achieved 80.2% coverage of the total body volume within ±10% of the prescription dose. The mean lung dose was 8.1 Gy. All ion chamber measurements were within ±1.7% compared to the calculated point doses. All relative film dosimetry showed at least a 98.0% gamma passing rate using a 3mm/3% passing criteria. Conclusion: The proposed patient comfort-oriented TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs

  4. Application of neutron multiplicity counting to waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, M.M.; Ensslin, N. [Los Alamos National Lab., NM (United States); Sharpe, T.J. [North Carolina State Univ., Raleigh, NC (United States)

    1997-11-01

    This paper describes the use of a new figure of merit code that calculates both bias and precision for coincidence and multiplicity counting, and determines the optimum regions for each in waste assay applications. A {open_quotes}tunable multiplicity{close_quotes} approach is developed that uses a combination of coincidence and multiplicity counting to minimize the total assay error. An example is shown where multiplicity analysis is used to solve for mass, alpha, and multiplication and tunable multiplicity is shown to work well. The approach provides a method for selecting coincidence, multiplicity, or tunable multiplicity counting to give the best assay with the lowest total error over a broad spectrum of assay conditions. 9 refs., 6 figs.

  5. Whole-body counting and dietary surveys in Norway during the first year after the Chernobyl accident

    International Nuclear Information System (INIS)

    Strand, P.; Berteig, L.; Berthelsen, T.; Strand, T.; Boee, E.; Trygg, K.

    1989-01-01

    Doses to the Norwegian population from radiocaesium in food are estimated from whole-body counting and dietary surveys. The average effective dose equivalent during the first year after the Chernobyl accident is estimated to be between 0.12-0.25 mSv. One quarter of the dose is due to consumption of milk. For those of the population specially vulnerable (Lapps excluded), the dose is estimated to be about 1 mSv in the first year. Almost 90% of the dose is due to consumption of reindeer meat, freshwater fish and milk. The corresponding effective dose equivalent for Lapps was estimated to be between 1-3 mSv in the first year. More than 90% of the dose is due to consumption of reindeer meat. Without dietary changes the Lapps would probably have received doses 7-10 times higher. (author)

  6. The effect of post-wash total progressive motile sperm count and semen volume on pregnancy outcomes in intrauterine insemination cycles: a retrospective study.

    Science.gov (United States)

    Ok, Elvan Koyun; Doğan, Omer Erbil; Okyay, Recep Emre; Gülekli, Bülent

    2013-01-01

    The purpose of this study was to determine the impact of post-wash total progressive motile sperm count (TPMSC) and semen volume on pregnancy outcomes in intrauterine insemination (IUI) cycles. The retrospective study included a total of 156 cycles (141 couples) and was performed in our center over a 24-month period. The semen parameters were recorded for each man and each insemination. The semen samples were re-evaluated after the preparation process. Post-wash TPMSC values were divided into four groups; Group 1: 10×10(6). Post-wash inseminated semen volume was divided into three groups; Group 1: 0.3 mL; Group 2: 0.4 mL; Group 3: 0.5 mL. The effect of post-wash total progressive motile sperm and semen volume on pregnancy outcomes was evaluated. The pregnancy rates per cycle and per couple were 27.56% and 30.49%, respectively. There was not a significant relationship between the inseminated semen volume and pregnancy rate (p>0.05). However, a significant linear-by-linear association was documented between the TPMSC and pregnancy rate (p=0.042). Our findings suggest that the post-wash inseminated semen volume should be between 0.3-0.5 mL. An average post-wash total motile sperm count of 10×10(6) may be a useful threshold value for IUI success, but more studies are needed to determine a cut-off value for TPMSC.

  7. A mind you can count on: validating breath counting as a behavioral measure of mindfulness

    Directory of Open Access Journals (Sweden)

    Daniel B Levinson

    2014-10-01

    Full Text Available Mindfulness practice of present moment awareness promises many benefits, but has eluded rigorous behavioral measurement. To date, research has relied on self-reported mindfulness or heterogeneous mindfulness trainings to infer skillful mindfulness practice and its effects. In four independent studies with over 400 total participants, we present the first construct validation of a behavioral measure of mindfulness, breath counting. We found it was reliable, correlated with self-reported mindfulness, differentiated long-term meditators from age-matched controls, and was distinct from sustained attention and working memory measures. In addition, we employed breath counting to test the nomological network of mindfulness. As theorized, we found skill in breath counting associated with more meta-awareness, less mind wandering, better mood, and greater nonattachment (i.e. less attentional capture by distractors formerly paired with reward. We also found in a randomized online training study that 4 weeks of breath counting training improved mindfulness and decreased mind wandering relative to working memory training and no training controls. Together, these findings provide the first evidence for breath counting as a behavioral measure of mindfulness.

  8. Whole-body counters in Canada

    International Nuclear Information System (INIS)

    Letourneau, C.

    1986-08-01

    A compilation of whole-body counting existing across Canada was prepared by AECB (Atomic Energy Control Board) staff. This work was initiated so that AECB staff and other concerned parties would have this information readily available, especially during urgent situations. This report is to be used for reference purposes only, as it makes no attempt to judge the present state of the art of whole-body counting

  9. Long-term health effects of thorium compounds on exposed workers: the complete blood count

    International Nuclear Information System (INIS)

    Conibear, S.A.

    1981-01-01

    Two hundred seventy-three men exposed to thorium and other rare earths between 1940 and 1973 at a plant which refined monazite sand were studied at Argonne National Laboratory from 1976 to 1980. In vivo measurements of body burden were made by counting gamma rays emitted by daughter products of retained thorium and by measuring exhaled thoron. Health status was ascertained through questionnaire, physical examination, and clinical laboratory tests. Measured body burden was found to be higher in those with a history of longer exposure. All parameters of the complete blood count were examined for evidence of an effect due to thorium. Comparisons of high and low body burden groups showed that only age and cigarette smoking had an effect on complete blood count parameters

  10. Temporal aggregation of migration counts can improve accuracy and precision of trends

    Directory of Open Access Journals (Sweden)

    Tara L. Crewe

    2016-12-01

    Full Text Available Temporal replicate counts are often aggregated to improve model fit by reducing zero-inflation and count variability, and in the case of migration counts collected hourly throughout a migration, allows one to ignore nonindependence. However, aggregation can represent a loss of potentially useful information on the hourly or seasonal distribution of counts, which might impact our ability to estimate reliable trends. We simulated 20-year hourly raptor migration count datasets with known rate of change to test the effect of aggregating hourly counts to daily or annual totals on our ability to recover known trend. We simulated data for three types of species, to test whether results varied with species abundance or migration strategy: a commonly detected species, e.g., Northern Harrier, Circus cyaneus; a rarely detected species, e.g., Peregrine Falcon, Falco peregrinus; and a species typically counted in large aggregations with overdispersed counts, e.g., Broad-winged Hawk, Buteo platypterus. We compared accuracy and precision of estimated trends across species and count types (hourly/daily/annual using hierarchical models that assumed a Poisson, negative binomial (NB or zero-inflated negative binomial (ZINB count distribution. We found little benefit of modeling zero-inflation or of modeling the hourly distribution of migration counts. For the rare species, trends analyzed using daily totals and an NB or ZINB data distribution resulted in a higher probability of detecting an accurate and precise trend. In contrast, trends of the common and overdispersed species benefited from aggregation to annual totals, and for the overdispersed species in particular, trends estimating using annual totals were more precise, and resulted in lower probabilities of estimating a trend (1 in the wrong direction, or (2 with credible intervals that excluded the true trend, as compared with hourly and daily counts.

  11. Quantitation of the degree of osteoporosis by measure of total-body calcium employing neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Zanzi, I.; Vaswani, A.; Wallach, S.; Aloia, J.; Ellis, K.J.

    1975-01-01

    Two techniques for measuring the amount of Ca in the total skeleton were employed: total-body neutron activation analysis (TBNAA) and the determination of the mineral content of a bone of the appendicular skeleton (absorptiometric measurement of the radius, BMC). (U.S.)

  12. Quantification of protein based on single-molecule counting by total internal reflection fluorescence microscopy with adsorption equilibrium

    International Nuclear Information System (INIS)

    Wang Lei; Xu Guang; Shi Zhikun; Jiang Wei; Jin Wenrui

    2007-01-01

    We developed a sensitive single-molecule imaging method for quantification of protein by total internal reflection fluorescence microscopy with adsorption equilibrium. In this method, the adsorption equilibrium of protein was achieved between solution and glass substrate. Then, fluorescence images of protein molecules in a evanescent wave field were taken by a highly sensitive electron multiplying charge coupled device. Finally, the number of fluorescent spots corresponding to the protein molecules in the images was counted. Alexa Fluor 488-labeled goat anti-rat IgG(H + L) was chosen as the model protein. The spot number showed an excellent linear relationship with protein concentration. The concentration linear range was 5.4 x 10 -11 to 8.1 x 10 -10 mol L -1

  13. Effects of Zinc Compound on Body Weight and Recovery of Bone Marrow in Mice Treated with Total Body Irradiation

    Directory of Open Access Journals (Sweden)

    Ming-Yii Huang

    2007-09-01

    Full Text Available This study aimed to investigate if zinc compound would have effects on body weight loss and bone marrow suppression induced by total body irradiation (TBI. ICR mice were divided randomly into two groups and treated with test or control compounds. The test compound contained zinc (amino acid chelated with bovine prostate extract, and the control was reverse osmosis pure water (RO water. One week after receiving the treatment, mice were unirradiated, or irradiated with 6 or 3 Gy by 6MV photon beams to the total body. Body weight changes were examined at regular intervals. Three and 5 weeks after the radiation, animals were sacrificed to examine the histologic changes in the bone marrow. Lower body weight in the period of 1-5 weeks after radiation and poor survival rate were found after the 6 Gy TBI, as compared with the 3 Gy groups. The median survival time after 6 Gy and 3 Gy TBI for mice given the test compound were 26 and 76 days, respectively, and the corresponding figures were 14 and 70 days, respectively, for mice given the control compound (p < 0.00001. With zinc supplement, the mean body weight in mice which received the same dose of radiation was 7-8 g heavier than in the water-supplement groups during the second and third weeks (p < 0.05. Hence, there was no statistically significant difference in survival rate between zinc and water supplement in mice given the same dose of irradiation. Histopathologically there was less recovery of bone marrow cells in the 6Gy groups compared with the 3Gy groups. In the 3 Gy water-supplement group, the nucleated cells and megakaryocytes were recovered in the fifth week when recovery was still not seen in the 6Gy group. With zinc supplement, these cells were recovered in the third week. In this study, we found that zinc is beneficial to body weight in mice treated with TBI. Histologic examination of bone marrow showed better recovery of bone marrow cells in groups of mice fed with zinc. This study

  14. Hepatic, renal, and total body galactose elimination in the pig

    DEFF Research Database (Denmark)

    Winkler, K; Henriksen, Jens Henrik Sahl; Tygstrup, N

    1993-01-01

    Galactose elimination capacity is used as a quantitative measure of liver function on the assumption that galactose elimination outside the liver is negligible or easily corrected for. The relationship between hepatic and extrahepatic removal of galactose was studied in anesthetized pigs during...... reabsorption (Tm 178 +/- 3.0 mumol/min, Km 3.8 +/- 0.9 mmol/l, n = 20). Metabolic conversion of galactose in the kidney was not demonstrable. At all concentrations studied (0.4-5.8 mmol/l), total galactose elimination from the body exceeded the sum of hepatic and renal elimination by approximately 100 mumol....../min, independent of the concentration. At blood concentrations usually used for clinical estimation of the galactose elimination capacity (approximately 4 mmol/l), hepatic removal in the pig accounted for 55% and renal removal for 30% of total removal; 15% of removal occurred in other organs. We conclude...

  15. The relationship of total body composition with bone mineral density in postmenopausal women with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Vadim Valer'evich Klimontov

    2015-03-01

    Full Text Available Aim. To determine the relationship between bone mineral density (BMD and total body composition in postmenopausal women with type 2 diabetes. Materials and Methods. The study included 78 women, from 50 to 70 years of age (median 63 years. Twenty women had normal body mass index (BMI, 29 ones were overweight and 29 had obesity. The body composition and BMD was studied by dual-energy X-ray absorptiometry. Results. Women with normal BMD had higher BMI, total and truncal fat mass, as well lean mass as compared to women with osteoporosis and osteopenia (all p

  16. Renal toxicity in children undergoing total body irradiation for bone marrow transplant

    International Nuclear Information System (INIS)

    Esiashvili, Natia; Chiang, K.-Y.; Hasselle, Michael D.; Bryant, Cynthia; Riffenburgh, Robert H.; Paulino, Arnold C.

    2009-01-01

    Purpose: Contribution of total body irradiation (TBI) to renal toxicity in children undergoing the bone marrow transplant (BMT) remains controversial. We report our institutional retrospective study that evaluates the frequency of acute and chronic renal dysfunction in children after using total body irradiation (TBI) conditioning regimens. Materials and methods: Between 1995 and 2003, 60 children with hematological malignancies underwent TBI as part of a conditioning regimen before allogeneic BMT. Patients received 4-14 Gy at 1.75-2 Gy/fraction in six-eight fractions. Lung shielding was used in all patients to limit lung dose to less than 10 Gy; renal shielding was not utilized. All patients had baseline renal function assessment and renal dysfunction post-BM was mainly evaluated on the basis of persistent serum creatinine elevation at acute (0-90 days) and chronic (>90 days) intervals after completion of BMT. Results: Acute renal dysfunction (ARD) was documented in 27 patients (45%); the majority had concurrent diagnosis of veno-occlusive disease (VOD) or graft-versus-host disease (GVHD) and other potential causes (sepsis, antibiotic). The risk for delayed renal dysfunction (DRD) at 1 year approached 25% for surviving patients. The ARD was strongly linked with the risk of the DRD. There was no statistically significant relationship between ARD, DRD and underlying diagnosis, GVHD, VOD or TBI doses with both univariate and multivariate analyses. The younger age (<5 years) had significantly increased risk for the development of ARD (p = 0.011). Conclusion: Our analysis validates high incidence of renal dysfunction in the pediatric BMT population. In contrast to other reports we did not find total body irradiation dose to be a risk factor for renal dysfunction. Future prospective studies are needed to assess risk factors and interventions for this serious toxicity in children following allogeneic BM

  17. Nation-wide anthropometric survey data in Japan to determine dimensions of total-body phantom for Reference Japanese Man

    International Nuclear Information System (INIS)

    Togo, Masami

    1990-01-01

    In order to estimate radiation dose in Japanese population accurately, a Reference Japanese Man, whose stature and body weight are 170cm and 60kg respectively, is indispensable. The MIRD 5 total-body phantom has only 8 dimensions, i.e. total head height, head length, head breadth, trunk length, trunk breadth, leg length, and breadth and depth of a leg model at its lower end. Based on Japanese anthropometric data, the dimensions were determined and its mathematical descriptions were given. In Japan, annual statistical data of stature, body weight, chest circumference and sitting height for all Japan by sex and age are published. But other nation-wide survey data necessary for determining dimensions of total-body phantom of Reference Japanese Man, are unavailable. Much more national anthropometric data of every kind necessary for defining phantoms must be compiled. (author)

  18. Investigation of internal conversion electron lines by track counting technique

    CERN Document Server

    Islamov, T A; Kambarova, N T; Muminov, T M; Lebedev, N A; Solnyshkin, A A; Aleshin, Yu D; Kolesnikov, V V; Silaev, V I; Niipf-Tashgu, T

    2001-01-01

    The methodology of counting the tracks of the internal conversion electron (ICE) in the nuclear photoemulsion is described. The results on counting the ICE tracks on the photoplates for sup 1 sup 6 sup 1 Ho, sup 1 sup 6 sup 3 Tm, sup 1 sup 6 sup 6 Tm, sup 1 sup 3 sup 5 Ce is described. The above results are obtained through the MBI-9 microscope and the MAS-1 automated facility. The ICE track counting on the photoplates provides for essentially higher sensitivity as compared to the photometry method. This makes it possible to carry out measurements with the sources by 1000 times weaker as by the study into the density of blackening

  19. The ORNL whole body counter

    International Nuclear Information System (INIS)

    1988-01-01

    This report is a non-technical document intended to provide an individual about to undergo a whole-body radiation count with a general understanding of the counting procedure and with the results obtained. 9 figs

  20. SU-E-T-357: Electronic Compensation Technique to Deliver Total Body Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [State University of New York at Buffalo, Buffalo, NY (United States); Wang, I; Podgorsak, M [State University of New York at Buffalo, Buffalo, NY (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient’s immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has conventionally been used to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Methods: Treatment plans utilizing electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two, specifically weighted, pair of opposed fields. One pair of open, large fields (collimator=45°), to encompass the patient’s entire anatomy, and one pair of smaller fields (collimator=0°) focused only on the thicker midsection of the patient. The optimal fluence for each one of the smaller fields was calculated at a patient specific penetration depth. Irregular surface compensators provide a more uniform dose distribution within the smaller opposed fields. Results: Dose-volume histograms (DVH) were calculated for the evaluating the electronic compensation technique. In one case, the maximum body doses calculated from the DVH were reduced from the non-compensated 195.8% to 165.3% in the electronically compensated plans, indicating a more uniform dose with the region of electronic compensation. The mean body doses calculated from the DVH were also reduced from the non-compensated 120.6% to 112.7% in the electronically compensated plans, indicating a more accurate delivery of the prescription dose. All calculated monitor units were well within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not substantially increase the beam on time while it can significantly reduce the compensator

  1. Chondrosarcoma arising within a radiation-induced osteochondroma several years following childhood total body irradiation: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Shuji [Kurume University Hospital, Department of Radiology, Fukuoka (Japan); Shen, Robert K. [Mayo Clinic, Department of Surgery, Rochester, MN (United States); Laack, Nadia N. [Mayo Clinic, Department of Radiation Oncology, Rochester, MN (United States); Inwards, Carrie Y. [Mayo Clinic, Department of Pathology, Rochester, MN (United States); Wenger, Doris E.; Amrami, Kimberly K. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2013-08-15

    Malignant degeneration arising in radiation-induced osteochondromas is extremely rare. We report a case of a 34-year-old man with a chondrosarcoma arising from an osteochondroma of the left posterior eighth rib that developed following total body irradiation received as part of the conditioning regimen prior to bone marrow transplantation at age 8. To our knowledge, this is only the fourth reported case of a chondrosarcoma arising within a radiation-induced osteochondroma and the first case occurring following childhood total body irradiation. (orig.)

  2. Chondrosarcoma arising within a radiation-induced osteochondroma several years following childhood total body irradiation: Case report

    International Nuclear Information System (INIS)

    Nagata, Shuji; Shen, Robert K.; Laack, Nadia N.; Inwards, Carrie Y.; Wenger, Doris E.; Amrami, Kimberly K.

    2013-01-01

    Malignant degeneration arising in radiation-induced osteochondromas is extremely rare. We report a case of a 34-year-old man with a chondrosarcoma arising from an osteochondroma of the left posterior eighth rib that developed following total body irradiation received as part of the conditioning regimen prior to bone marrow transplantation at age 8. To our knowledge, this is only the fourth reported case of a chondrosarcoma arising within a radiation-induced osteochondroma and the first case occurring following childhood total body irradiation. (orig.)

  3. Determining Gate Count Reliability in a Library Setting

    Directory of Open Access Journals (Sweden)

    Jeffrey Phillips

    2016-09-01

    Full Text Available Objective – Patron counts are a common form of measurement for library assessment. To develop accurate library statistics, it is necessary to determine any differences between various counting devices. A yearlong comparison between card reader turnstiles and laser gate counters in a university library sought to offer a standard percentage of variance and provide suggestions to increase the precision of counts. Methods – The collection of library exit counts identified the differences between turnstile and laser gate counter data. Statistical software helped to eliminate any inaccuracies in the collection of turnstile data, allowing this data set to be the base for comparison. Collection intervals were randomly determined and demonstrated periods of slow, average, and heavy traffic. Results – After analyzing 1,039,766 patron visits throughout a year, the final totals only showed a difference of .43% (.0043 between the two devices. The majority of collection periods did not exceed a difference of 3% between the counting instruments. Conclusion – Turnstiles card readers and laser gate counters provide similar levels of reliability when measuring patron activity. Each system has potential counting inaccuracies, but several methods exist to create more precise totals. Turnstile card readers are capable of offering greater detail involving patron identity, but their high cost makes them inaccessible for libraries with lower budgets. This makes laser gate counters an affordable alternative for reliable patron counting in an academic library.

  4. Renal toxicity after total body irradiation

    International Nuclear Information System (INIS)

    Borg, Martin; Hughes, Timothy; Horvath, Noemi; Rice, Michael; Thomas, Anthony C.

    2002-01-01

    Purpose: To evaluate the incidence of renal dysfunction after total body irradiation (TBI). Methods and Materials: Between 1990 and 1997, 64 patients (median age 50 years) received TBI as part of the conditioning regimen before bone marrow transplantation (BMT). Five patients with abnormal renal function at the beginning of treatment or with incomplete data were excluded. All patients received a total of 12 Gy (6 fractions twice daily for 3 consecutive days) prescribed to the peak lung dose (corrected for lung transmission) at a dose rate of 7.5 cGy/min. Renal shielding was not used. Renal dysfunction was assessed on the basis of the serum creatinine levels measured at the start and end of TBI and at 6, 12, 18, and 24 months after completion of BMT. Cox proportional hazard analysis was used to evaluate the various factors known to affect renal function. Results: Only 4 patients had elevated serum creatinine levels at 12 months and subsequently only 2 of the 33 surviving patients had persistent elevated renal serum creatinine levels 24 months after BMT. A fifth patient developed proteinuria and mildly elevated serum creatinine levels at 2.5 years. In 2 patients, the elevation coincided with disease relapse and normalized once remission was achieved. In the third patient, the elevation in serum creatinine levels coincided with relapse of multiple myeloma and the presence of Bence-Jones proteinuria. The fourth patient was the only patient who developed chronic renal failure secondary to radiation nephritis at 2 years. The etiology of the fifth patient's rise in creatinine was unknown, but may have been secondary to radiation nephritis. On univariate analysis, but not on multivariate analysis, a significant correlation was found between TBI-related renal dysfunction and hypertension before and after BMT. Conclusion: A dose of 12 Gy at 2 Gy/fraction resulted in only 1 case of radiation nephritis in the 59 patients studied 24 months after the completion of TBI and BMT

  5. 100 mg 251Cf activation analysis facility at the Savannah River Laboratory

    International Nuclear Information System (INIS)

    MacMurdo, K.W.; Bowman, W.W.

    1975-01-01

    The 252 Cf Activation Analysis Facility at the Savannah River Laboratory (SRL) is used routinely for multielement analyses of a wide variety of solid and liquid samples (e.g., metal alloys, fly ash and other airborne particles, rocks, and aqueous and nonaqueous solutions). An automated absolute activation analysis technique, developed to use neutron transport codes to calculate multienergy group neutron spectra and fluxes, converts counting data directly into elemental concentrations expressed in parts per million. The facility contains four sources of 252 Cf totaling slightly over 100 mg. A pneumatic ''rabbit'' system permits automatic irradiation/decay/counting regimes to be performed unattended on up to 100 samples. Detection sensitivities of less than or equal to 400 ppb natural uranium and less than or equal to 0.5 nCi/g for 239 Pu are observed. Detection limits for over 65 elements have been determined. Over 40 elements are detectable at the one part per million level or less. Overall accuracies of +- 10 percent are observed for most elements. (auth)

  6. The total body length and body weight examination among gabus Sentani fish population, Oxyeleotris heterodon, Weber 1907 (Pisces: Eleotridae) of Sentani lake, Papua, Indonesia

    Science.gov (United States)

    Sriyani, E. D.; Abinawanto, Bowolaksono, A.

    2017-07-01

    The gabus Sentani fish lived in the Sentani Lake, Papua, since million years ago. Nowadays, the population of those species is getting extinct because of the overexploitation, whereas the culture effort of this species has not been developed, yet. The purpose of the study was to examine the total body length and body weight collected from some villages surrounding Sentani Lake such as Ifar village, Sosiri village, and Putali village. The body weight average of gabus fish from Ifar village, Sosiri village, and Putali village were 373.53 g, 426.86 g, and 118.34 g respectively. While the total body length average of gabus Sentani fish from Ifar village, Sosiri village, and Putali village were 279.30 mm, 223.30 mm and 222.06 mm, respectively. The growth model was W = 0.021067L3.086 with R2 value was 35.8 %, and r value was 0.598. Gabus Sentani fish, Oxyeleotris heterodon (Weber 1907) exhibited positive allometric (b > 3).

  7. Whole-body monitors for clinical uses

    International Nuclear Information System (INIS)

    Shilar, J.

    1977-01-01

    The construction and parameters are described of the CD-2 spectrometer of human radiation, created in 1971. The spectrometer is designed for activity investigation in man's body and measurement of extent of contamination of men by gamma radiation in case of accidents. An axial configuration of two pairs of scintillation detectors, using NaJ(Tl) 100x120 mm crystals is used in the facility. The resultant energy resolution by cesium-137 is from 10.5 to 11%. The counting rates for energies higher than 100 keV - 1.5x10 4 imp/min. Measurements performed on phantoms, testify to the possibility of using the CD-2 facility in interaction with the TESLA NZG 312-T data processing equipment for determining the extent of men's contamination by gamma radiation sources in the activity range approximately from 800 Bq to 74 Bq, for gamma radiaiton sources with gamma-photon energy higher than 300 keV recounting error of signal pulse number detected at the integral work performance does not exceed 50%

  8. Whole-body irradiation technique: physical aspects; Tecnica de irradiacion corporal total: aspectos fisicos

    Energy Technology Data Exchange (ETDEWEB)

    Venencia, D.; Bustos, S.; Zunino, S. [Instituto Privado de Radioterapia. Obispo Oro 425. Cordoba 5000 (Argentina)

    1998-12-31

    The objective of this work has been to implement a Total body irradiation technique that fulfill the following conditions: simplicity, repeatability, fast and comfortable positioning for the patient, homogeneity of the dose between 10-15 %, short times of treatments and In vivo dosimetric verifications. (Author)

  9. Performance testing of radiobioassay laboratories: in-vivo measurements, pilot study report

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, A.V.; Fisher, D.R.; Reece, W.D.; MacLellan, J.A.

    1986-10-01

    This document describes a project to evaluate the in-vivo counting performance criteria of draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. The draft ANSI Standard provides guidance to in-vivo counting facilities regarding the precision and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. The draft ANSI Standard was evaluated by conducting an intercomparison test involving a number of whole-body counting facilities. The testing involved three types of measurements: chest counting for detection of radioactive materials in the lung, whole-body counting for detection of uniformly distributed activity, and neck counting for detection of radioactive material concentrated in the thyroid. Results of the first-round intercomparison test are presented in this report. The appropriateness of the draft Standard performance criteria was judged by the measurement results reported by participating in-vivo counting facilities. The intercomparison testing showed that some laboratories had difficulty meeting the performance criteria specified in the draft ANSI Standard N13.30.

  10. Performance testing of radiobioassay laboratories: in-vivo measurements, pilot study report

    International Nuclear Information System (INIS)

    Robinson, A.V.; Fisher, D.R.; Reece, W.D.; MacLellan, J.A.

    1986-10-01

    This document describes a project to evaluate the in-vivo counting performance criteria of draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. The draft ANSI Standard provides guidance to in-vivo counting facilities regarding the precision and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. The draft ANSI Standard was evaluated by conducting an intercomparison test involving a number of whole-body counting facilities. The testing involved three types of measurements: chest counting for detection of radioactive materials in the lung, whole-body counting for detection of uniformly distributed activity, and neck counting for detection of radioactive material concentrated in the thyroid. Results of the first-round intercomparison test are presented in this report. The appropriateness of the draft Standard performance criteria was judged by the measurement results reported by participating in-vivo counting facilities. The intercomparison testing showed that some laboratories had difficulty meeting the performance criteria specified in the draft ANSI Standard N13.30

  11. Guide to user facilities at the Lawrence Berkeley Laboratory

    International Nuclear Information System (INIS)

    1984-04-01

    Lawrence Berkeley Laboratories' user facilities are described. Specific facilities include: the National Center for Electron Microscopy; the Bevalac; the SuperHILAC; the Neutral Beam Engineering Test Facility; the National Tritium Labeling Facility; the 88 inch Cyclotron; the Heavy Charged-Particle Treatment Facility; the 2.5 MeV Van de Graaff; the Sky Simulator; the Center for Computational Seismology; and the Low Background Counting Facility

  12. Metal ion levels and lymphocyte counts

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Varmarken, Jens-Erik; Ovesen, Ole

    2013-01-01

    BACKGROUND AND PURPOSE: Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA) an....../ppb. INTERPRETATION: Circulating T-lymphocyte levels may decline after surgery, regardless of implant type. Metal ions-particularly cobalt-may have a general depressive effect on T- and B-lymphocyte levels. Registered with ClinicalTrials.gov under # NCT01113762.......BACKGROUND AND PURPOSE: Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA....... RESULTS: The T-lymphocyte counts for both implant types declined over the 2-year period. This decline was statistically significant for CD3(+)CD8(+) in the THA group, with a regression coefficient of -0.04 × 10(9)cells/year (95% CI: -0.08 to -0.01). Regression analysis indicated a depressive effect...

  13. Stress-reaction during hypokinesia and its effect on total resistance of the animal body

    International Nuclear Information System (INIS)

    Chernov, I.P.

    1980-01-01

    In the experiments on rats, shown has been that three-phase stress-reaction develops during the hypokinetic syndrome formation. This reaction is confirmed by specific changes of general state of the organism, body mass and by the activity of hypothalamic-hypophysial-adrenal system evaluated by oscillations of relative mass of pituitary body and adrenal glands and by karyometry of neuron of the hypothalamus arcuate nuclear and cells of zona fasciculata of adrenal glands. The hypokinetic stress affects the total resistance of the body, its sensitivity to gamma-irradiation in the dose of 800 rad. On the definite stage of development the hypokinetic stress forms the state of heightened ''cross'' stability

  14. Influence of physical activity on the metabolism and the total body content of sodium and potassium in the rat

    International Nuclear Information System (INIS)

    Yeh, J.K.; Yasumura, A.; Aloia, J.F.

    1986-01-01

    The purpose of this study was to investigate the effect of exercise (EX) and immobilization (IMB) on the absorption, excretion and total body content of sodium (TBNa) and potassium (TBK). Female Sprague Dawley rats 5 weeks old were divided into four groups: EX; Control (CON); EX with pair feeding to the level equal to the CON (EX-P); IMB by sciatica denervation. The nutritional balance study data was taken 5 weeks into the experimental period and the animals were sacrificed after 5 additional weeks of experimentation. The carcasses were kept frozen and used for total body composition by neutron activation. The results of the total body composition show that EX resulted in an increase, IMB resulted in a decrease, of the TBNa and TBK. There was no significant difference in TBNa of TBK, between the EX and the EX-P groups even though, the food intake was higher in the EX group. The results of the nutritional balance study confirmed the results of the total body composition

  15. Total-body photography in skin cancer screening: the clinical utility of standardized imaging.

    Science.gov (United States)

    Rosenberg, Alexandra; Meyerle, Jon H

    2017-05-01

    Early detection of skin cancer is essential to reducing morbidity and mortality from both melanoma and nonmelanoma skin cancers. Total-body skin examinations (TBSEs) may improve early detection of malignant melanomas (MMs) but are controversial due to the poor quality of data available to establish a mortality benefit from skin cancer screening. Total-body photography (TBP) promises to provide a way forward by lowering the costs of dermatologic screening while simultaneously leveraging technology to increase patient access to dermatologic care. Standardized TBP also offers the ability for dermatologists to work synergistically with modern computer technology involving algorithms capable of analyzing high-quality images to flag concerning lesions that may require closer evaluation. On a population level, inexpensive TBP has the potential to increase access to skin cancer screening and it has several specific applications in a military population. The utility of standardized TBP is reviewed in the context of skin cancer screening and teledermatology.

  16. In vivo dosimetry with silicon diodes in total body irradiation

    International Nuclear Information System (INIS)

    Oliveira, F.F.; Amaral, L.L.; Costa, A.M.; Netto, T.G.

    2014-01-01

    The aim of this work is the characterization and application of silicon diode detectors for in vivo dosimetry in total body irradiation (TBI) treatments. It was evaluated the diode response with temperature, dose rate, gantry angulations and field size. A maximum response variation of 2.2% was obtained for temperature dependence. The response variation for dose rate and angular was within 1.2%. For field size dependence, the detector response increased with field until reach a saturation region, where no more primary radiation beam contributes for dose. The calibration was performed in a TBI setup. Different lateral thicknesses from one patient were simulated and then the calibration factors were determined by means of maximum depth dose readings. Subsequent to calibration, in vivo dosimetry measurements were performed. The response difference between diode readings and the prescribed dose for all treatments was below 4%. This difference is in agreement as recommended by the International Commission on Radiation Units and Measurements (ICRU), which is ±5%. The present work to test the applicability of a silicon diode dosimetry system for performing in vivo dose measurements in TBI techniques presented good results. These measurements demonstrated the value of diode dosimetry as a treatment verification method and its applicability as a part of a quality assurance program in TBI treatments. - Highlights: ► Characterization of a silicon diode dosimetry system. ► Application of the diodes for in vivo dosimetry in total body irradiation treatments. ► Implementation of in vivo dosimetry as a part of a quality assurance program in radiotherapy

  17. Can tritiated water-dilution space accurately predict total body water in chukar partridges

    International Nuclear Information System (INIS)

    Crum, B.G.; Williams, J.B.; Nagy, K.A.

    1985-01-01

    Total body water (TBW) volumes determined from the dilution space of injected tritiated water have consistently overestimated actual water volumes (determined by desiccation to constant mass) in reptiles and mammals, but results for birds are controversial. We investigated potential errors in both the dilution method and the desiccation method in an attempt to resolve this controversy. Tritiated water dilution yielded an accurate measurement of water mass in vitro. However, in vivo, this method yielded a 4.6% overestimate of the amount of water (3.1% of live body mass) in chukar partridges, apparently largely because of loss of tritium from body water to sites of dissociable hydrogens on body solids. An additional source of overestimation (approximately 2% of body mass) was loss of tritium to the solids in blood samples during distillation of blood to obtain pure water for tritium analysis. Measuring tritium activity in plasma samples avoided this problem but required measurement of, and correction for, the dry matter content in plasma. Desiccation to constant mass by lyophilization or oven-drying also overestimated the amount of water actually in the bodies of chukar partridges by 1.4% of body mass, because these values included water adsorbed onto the outside of feathers. When desiccating defeathered carcasses, oven-drying at 70 degrees C yielded TBW values identical to those obtained from lyophilization, but TBW was overestimated (0.5% of body mass) by drying at 100 degrees C due to loss of organic substances as well as water

  18. Risk communication with Fukushima residents affected by the Fukushima Daiichi accident at whole-body counting

    Energy Technology Data Exchange (ETDEWEB)

    Gunji, I.; Furuno, A.; Yonezawa, R.; Sugiyama, K. [Risk Communication Study Office, Japan Atomic Energy Agency 4-33 Muramatsu, Tokai-mura, Ibaraki, 319-1194 (Japan)

    2013-07-01

    After the Tokyo Electric Power Company (TEPCO) Fukushima Daiichi nuclear power plant accident, the Tokai Research and Development Center of the Japan Atomic Energy Agency (JAEA) have had direct dialogue as risk communication with Fukushima residents who underwent whole-body counting examination (WBC). The purpose of the risk communication was to exchange information and opinions about radiation in order to mitigate Fukushima residents' anxiety and stress. Two kinds of opinion surveys were performed: one survey evaluated residents' views of the nuclear accident itself and the second survey evaluated the management of WBC examination as well as the quality of JAEA's communication skills on risks. It appears that most Fukushima residents seem to have reduced their anxiety level after the direct dialogue. The results of the surveys show that Fukushima residents have the deepest anxiety and concern about their long-term health issues and that they harbor anger toward the government and TEPCO. On the other hand, many WBC patients and patients' relatives have expressed gratitude for help in reducing their feelings of anxiety.

  19. Risk communication with Fukushima residents affected by the Fukushima Daiichi accident at whole-body counting

    International Nuclear Information System (INIS)

    Gunji, I.; Furuno, A.; Yonezawa, R.; Sugiyama, K.

    2013-01-01

    After the Tokyo Electric Power Company (TEPCO) Fukushima Daiichi nuclear power plant accident, the Tokai Research and Development Center of the Japan Atomic Energy Agency (JAEA) have had direct dialogue as risk communication with Fukushima residents who underwent whole-body counting examination (WBC). The purpose of the risk communication was to exchange information and opinions about radiation in order to mitigate Fukushima residents' anxiety and stress. Two kinds of opinion surveys were performed: one survey evaluated residents' views of the nuclear accident itself and the second survey evaluated the management of WBC examination as well as the quality of JAEA's communication skills on risks. It appears that most Fukushima residents seem to have reduced their anxiety level after the direct dialogue. The results of the surveys show that Fukushima residents have the deepest anxiety and concern about their long-term health issues and that they harbor anger toward the government and TEPCO. On the other hand, many WBC patients and patients' relatives have expressed gratitude for help in reducing their feelings of anxiety

  20. Quantitative clinical uptake measurements using conjugate counting

    International Nuclear Information System (INIS)

    Lathrop, K.A.; Bartlett, R.D.; Chen, C.T.; Chou, J.S.; Faulhaber, P.F.; Harper, P.V.; Stark, V.J.

    1986-01-01

    While the use of conjugate counting for determination of organ uptake in human subjects has been extensively described, in the present study the determination of the organ uptake of ortho-iodohippurate presented several opportunities for validation of the in vivo counting data. Ortho-iodohippurate is distributed in the extracellular space, is largely extracted on each pass through the kidneys, and is not significantly deiodinated in vivo. Thus, the kidney uptake rate should be proportional to the blood level, the appearance rate of activity in the bladder is equal to the disappearance rate from the kidneys, and direct measurement of activity in the urine after voiding provides an internal standard for imaging measurements of bladder activity. Since the activity levels in the kidneys, bladder, and remainder of the body changed fairly rapidly, especially in the first 20 to 30 minutes following injection, posterior images of the trunk including kidneys and bladder were obtained continuously using a gamma camera fitted with a diverging collimator for 30 minutes and then at intervals for several hours. Simultaneous conjugate counting determinations were made using a whole body scanning system previously described at these meetings. Imaging data corrected for decay and adjacent background were fitted by least squares methods to curves representing a sum of exponentials, and the curves were normalized to the conjugate uptake measurements. The uptake curves of the kidneys and bladder matched well with the direct measurements of the urinary excretion. Data were collected in 16 normal subjects, and the estimated absorbed dose was calculated for the kidneys, the bladder and the remainder of the body for seven radioisotopes of iodine. 4 references, 6 figures, 2 tables

  1. Temporal trends in sperm count

    DEFF Research Database (Denmark)

    Levine, Hagai; Jørgensen, Niels; Martino-Andrade, Anderson

    2017-01-01

    a predefined protocol 7518 abstracts were screened and 2510 full articles reporting primary data on SC were reviewed. A total of 244 estimates of SC and TSC from 185 studies of 42 935 men who provided semen samples in 1973-2011 were extracted for meta-regression analysis, as well as information on years.......006, respectively). WIDER IMPLICATIONS: This comprehensive meta-regression analysis reports a significant decline in sperm counts (as measured by SC and TSC) between 1973 and 2011, driven by a 50-60% decline among men unselected by fertility from North America, Europe, Australia and New Zealand. Because......BACKGROUND: Reported declines in sperm counts remain controversial today and recent trends are unknown. A definitive meta-analysis is critical given the predictive value of sperm count for fertility, morbidity and mortality. OBJECTIVE AND RATIONALE: To provide a systematic review and meta-regression...

  2. Total lymphoid irradiation and total body irradiation for allogeneic bone marrow transplantation in aplastic anemia

    Energy Technology Data Exchange (ETDEWEB)

    Kurisu, Koichi; Hishikawa, Yoshio; Taniguchi, Midori; Kamikonya, Norihiko; Miura, Takashi; Kanamaru, Akihisa; Kakishita, Eizo; Kai, Shunro; Hara, Hiroshi (Hyogo Coll. of Medicine, Nishinomiya (Japan))

    Between April 1980 and June 1989, 15 patients with severe aplastic anemia (SAA) were treated at Hyogo College of Medicine with bone marrow transplantation (BMT) after preparation consisting of cyclophosphamide (CY) and total lymphoid irradiation (TLI) or total body irradiation (TBI) for the purpose of reducing the incidence of graft rejection. All patients had initial evidence of engraftment after the first transplantation except for one patient who died of heart failure due to CY on the third day after transplantation and could not be evaluated for engraftment. Rejection later occurred in four of these 14 patients, who then underwent successful regrafting. One of these four patients, who was conditioned with CY alone at the first grafting, underwent successful regrafting after a conditioning regimen of CY and TBI. In the other three patients, irradiation was performed twice as the conditioning regimen. Thus, 14 of 15 patients underwent successful BMT and are alive with restored hematopoietic function. From the above results, the combination of TLI or TBI and CY was considered to be very useful as a conditioning regimen for BMT in patients with SAA. (author).

  3. Analytical methods and laboratory facility for the Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Dewberry, R.A.; Lethco, A.J.; Denard, C.D.

    1985-01-01

    This paper describes the analytical methods, instruments, and laboratory that will support vitrification of defense waste. The Defense Waste Processing Facility (DWPF) is now being constructed at Savannah River Plant (SRP). Beginning in 1989, SRP high-level defense waste will be immobilized in borosilicate glass for disposal in a federal repository. The DWPF will contain an analytical laboratory for performing process control analyses. Additional analyses will be performed for process history and process diagnostics. The DWPF analytical facility will consist of a large shielded sampling cell, three shielded analytical cells, a laboratory for instrumental analysis and chemical separations, and a counting room. Special instrumentation is being designed for use in the analytical cells, including microwave drying/dissolution apparatus, and remote pipetting devices. The instrumentation laboratory will contain inductively coupled plasma, atomic absorption, Moessbauer spectrometers, a carbon analyzer, and ion chromatography equipment. Counting equipment will include intrinsic germanium detectors, scintillation counters, Phoswich alpha, beta, gamma detectors, and a low-energy photon detector

  4. Total body irradiation in bone marrow transplantation

    International Nuclear Information System (INIS)

    Gluckman, E.; Devergie, A.; Boiron, M.; Bernard, Jean; Dutreix, A.; Dutreix, J.

    1979-01-01

    Total body irradiation was used in 22 patients as part of their conditioning regimen for bone marrow transplantation. Nine patients with acute leukemia received 1000 cGy TBI in addition with chemotherapy. None of them survived and the main cause of death was interstitial pneumonitis (50%). 4 patients received 1000 cGy with a lung shielding of 500 cGy. Two patients with acute leukemia died of leukemia and sepsis, two patients had aplastic anemia, one is surviving, the other died of severe GVHD and infectious complications. Nine patients with severe aplastic anemia strongly immunized by previous blood transfusions received 800 cGy TBI with a lung shielding of 400 cGy. No rejection was observed and 7 patients (63%) are currently alive. One patient died of interstitial pneumonitis probably related to CMV infection, one of subacute necrotizing hepatitis, two of severe acute GVHD. It is concluded from this study that TBI remains the best immunosuppressive conditioning regimen even in strongly immunized patients. It may be a contributing factor of the incidence and severity of interstitial pneumonitis. A reduction of the dose of the lung to 400-500 cGy seems to decrease the severity of this complication

  5. Radiobiological speculations on therapeutic total body irradiation

    International Nuclear Information System (INIS)

    Vriesendorp, H.M.

    1990-01-01

    Unexpected total body irradiation (TBI) of human beings, involved in nuclear warfare or in accidents in nuclear reactors can be lethal. In the 1950s, bone marrow transplantation was discovered as a potentially life saving procedure after TBI in the dose range of 5.0 to 12.0 Gy. Since that time, deliberate or therapeutic TBI has been used to condition patients with a lethal bone marrow disorder for bone marrow replacement. The therapeutic ratio of TBI followed by bone marrow transplantation is small. Many potentially lethal complications can occur, such as acute TBI side effects, late TBI side effects or immunological complications of bone marrow transplantation such as graft versus host disease or graft rejection. The benefits of TBI and bone marrow transplantation are that they offer a chance for cure of previously lethal bone marrow disorders. The optimal parameters for TBI remain to be defined. The review discusses the current clinical and experimental animal data, as they relate to the future definition of less toxic TBI procedures with a better therapeutic ratio. Different TBI procedures are required for patients with malignant vs. non-malignant disorders or for patients with histoincompatible vs. histocompatible bone marrow donors.77 references

  6. Counting bodies? On future engagements with science studies in medical anthropology.

    Science.gov (United States)

    Yates-Doerr, Emily

    2017-08-01

    Thirty years ago, Nancy Scheper-Hughes and Margaret Lock outlined a strategy for 'future work in medical anthropology' that focused on three bodies. Their article - a zeitgeist for the field - sought to intervene into the Cartesian dualisms characterizing ethnomedical anthropology at the time. Taking a descriptive and diagnostic approach, they defined 'the mindful body' as a domain of future anthropological inquiry and mapped three analytic concepts that could be used to study it: the individual/phenomenological body, the social body, and the body politic. Three decades later, this paper returns to the 'three bodies'. It analyses ethnographic fieldwork on chronic illness, using a rescriptive, practice-oriented approach to bodies developed by science studies scholars that was not part of the initial three bodies framework. It illustrates how embodiment was a technical achievement in some practices, while in others bodies did not figure as relevant. This leads to the suggestion that an anthropology of health need not be organized around numerable bodies. The paper concludes by suggesting that future work in medical anthropology might embrace translational competency, which does not have the goal of better definitions (better health, better bodies, etc.) but the goal of better engaging with exchanges between medical and non-medical practices. That health professionals are themselves moving away from bodies to embrace 'planetary health' makes a practice-focused orientation especially crucial for medical anthropology today.

  7. Enhanced counting efficiency of Cerenkov radiation from bismuth-210

    International Nuclear Information System (INIS)

    Peck, G.A.; Smith, J.D.

    1998-01-01

    This paper describes the measurement of 210 Bi by Cerenkov counting in a commercial liquid scintillation counter. The counting efficiency in water is 0.17 counts per second per Becquerel (17%). When the enhancers Triton X-100 (15% v/v) and sodium salicylate (1% m/v) are added to the solution the counting efficiency for 210 Bi increases from 17% to 75%. The 210 Po daughter of 210 Bi causes interference of 0.85 counts per second per Becquerel in the presence of the enhancers but not in water. When 210 Bi and 210 Po are present in secular equilibrium the total counting efficiency is 160%. When 210 Bi and 210 Po are not in secular equilibrium the 210 Po can be removed immediately before counting by plating onto silver foil. The use of the enhancers gives a substantial increase in counting efficiency compared to counting in water. Compared with solutions used in liquid scintillation counting the enhancer solution is inexpensive and can be disposed of without environmental hazard. (author)

  8. Isolation of Mallory bodies and an attempt to demonstrate cell mediated immunity to Mallory body isolate in patients with alcoholic liver disease

    DEFF Research Database (Denmark)

    Gluud, C; Hardt, F; Aldershvile, J

    1981-01-01

    Mallory bodies were isolated from necropsy livers from patients with alcoholic hepatitis with and without cirrhosis with a Ficoll viscosity barrier. The purity of Mallory bodies in the isolate varied between 70 and 90%, estimated by counting Mallory bodies and non-Mallory body structures in haema...... was found between controls and patients with alcoholic hepatitis, alcoholic steatosis, alcoholic cirrhosis and miscellaneous liver diseases.......Mallory bodies were isolated from necropsy livers from patients with alcoholic hepatitis with and without cirrhosis with a Ficoll viscosity barrier. The purity of Mallory bodies in the isolate varied between 70 and 90%, estimated by counting Mallory bodies and non-Mallory body structures...

  9. Validity of dual X-ray absorptiometry scanning for determination of body composition in IDDM patients

    DEFF Research Database (Denmark)

    Rosenfalck, A M; Almdal, Thomas Peter; Gotfredsen, A

    1995-01-01

    Data on body composition in patients with insulin-dependent diabetes mellitus (IDDM) are scarce. Dual X-ray absorptiometry (DXA) scanning has proved useful for this purpose in other groups of patients. We tested the validity of the DXA scanner for the determination of fat-free mass (FFM) and fat...... mass in IDDM patients and control subjects, as compared to other reference methods, i.e. total body potassium by 40K whole body counting (TBK), total body water by tritiated water (TBW), bioelectrical impedance analysis (BIA) and 24-h urinary creatinine excretion (Ucrea). A total of 13 healthy controls....... The agreement between FFM estimated by DXA and the other methods, expressed as mean difference +/- 2 SD was; for DXA vs. TBK, 0.09 +/- 6.26 and 0.50 +/- 5.26 kg for controls and IDDM patients respectively; DXA vs. TBW, -2.07 +/- 2.56 and -1.07 +/- 4.58 kg; DXA vs. Ucrea, -2.62 +/- 8.02 and 2.00 +/- 10.0 kg; DXA...

  10. Skin tags: A link between lesional mast cell count/tryptase expression and obesity and dyslipidemia

    Directory of Open Access Journals (Sweden)

    Samar Abdallah M Salem

    2013-01-01

    Full Text Available Background:The etiology of skin tags (STs is not fully understood. A relation to diabetes mellitus and obesity was suggested. Few studies of possible mast cells (MCs involvement were reported. Tyrptase is a mast cell mediator and a potent fibroblast growth factor. It may provide a molecular link between mast cell activation and fibrosis. Aims: The aim was to assess clinical and laboratory findings in patients with STs, and the possible link between obesity, dyslipidemia, and lesional MC count/tryptase expression. Materials and Methods: A total of 20 patients with STs were subjected to clinical examination, estimation of body mass index (BMI, fasting blood glucose (FBG, postprandial blood glucose (PPBG, serum cholesterol and triglycerides, abdominal ultrasound for fatty liver assessment, in addition to study of MCs through staining for MC tryptase in two skin biopsies; lesional and nonlesional (control. Results:All patients showed abnormally high BMI and hypertriglyceridemia, with abnormal sonographic pattern in 15 patients (75%. STs number positively correlated with the age of patients. STs showed significantly higher MC counts and tryptase expression, compared with control skin ( P < 0.001, with no correlation of the STs number or MC count with BMI, FBG, PPBG or serum cholesterol. Obese patients showed a significantly higher MC count than overweight and there was a positive correlation between MC count and serum triglycerides. Axilla and under breast STs showed a higher MC count compared with other sites. Conclusions:STs seem to be related to obesity and hypertriglyceridemia. MCs with their tryptase are possibly involved in pathogenesis of STs. MC count is related to the associated factors; obesity and serum triglycerides. MC tryptase expression is a reliable method for accurate tissue MC counting.

  11. Comparative evolution of coagulation disorders in baboons and Pigs after total body irradiation

    International Nuclear Information System (INIS)

    Destombe, C.; Lefleche, P.; Veyret, J.; Grasseau, A.; Agay, D.; Mestries, J.C.

    1994-01-01

    Acute total body irradiation in pigs, with a lethal dose of either gamma or mixed gamma-neutron radiation, induced similar plasmatic coagulation disorders as those observed in baboons. These data validated pathophysiological hypothesis which were developed during previous studies, but do not support the idea of a possible species specific radiosensitivity. (author)

  12. Dosimetry for total body irradiation of rhesus monkeys with 300 kV X- rays

    NARCIS (Netherlands)

    Zoetelief, J.; Wagemaker, G.; Broerse, J.J.

    1998-01-01

    Purpose: To obtain more accurate information on the dose distribution in rhesus monkeys for total body irradiation with orthovoltage X-rays. Materials and methods: Dose measurements were performed with an ionization chamber inside homogeneous cylindrical and rectangular phantoms of various

  13. Post-laryngectomy localization of I-131 at tracheostomy site on a total body scan

    International Nuclear Information System (INIS)

    Kirk, G.A.; Schulz, E.E.

    1984-01-01

    A post-thyroidectomy, post-I-131-therapy patient had a laryngectomy and neck dissection for recurrent papillary thyroid carcinoma. A subsequent I-131 total body scan revealed persistent anterior neck activity, which disappeared upon removal of the tracheostomy tube and dressings

  14. First principle active neutron coincidence counting measurements of uranium oxide

    Energy Technology Data Exchange (ETDEWEB)

    Goddard, Braden, E-mail: goddard.braden@gmail.com [Nuclear Security Science and Policy Institute, Texas A and M University, College Station, Texas 77843 (United States); Charlton, William [Nuclear Security Science and Policy Institute, Texas A and M University, College Station, Texas 77843 (United States); Peerani, Paolo [European Commission, EC-JRC-ITU, Ispra (Italy)

    2014-03-01

    Uranium is present in most nuclear fuel cycle facilities ranging from uranium mines, enrichment plants, fuel fabrication facilities, nuclear reactors, and reprocessing plants. The isotopic, chemical, and geometric composition of uranium can vary significantly between these facilities, depending on the application and type of facility. Examples of this variation are: enrichments varying from depleted (∼0.2 wt% {sup 235}U) to high enriched (>20 wt% {sup 235}U); compositions consisting of U{sub 3}O{sub 8}, UO{sub 2}, UF{sub 6}, metallic, and ceramic forms; geometries ranging from plates, cans, and rods; and masses which can range from a 500 kg fuel assembly down to a few grams fuel pellet. Since {sup 235}U is a fissile material, it is routinely safeguarded in these facilities. Current techniques for quantifying the {sup 235}U mass in a sample include neutron coincidence counting. One of the main disadvantages of this technique is that it requires a known standard of representative geometry and composition for calibration, which opens up a pathway for potential erroneous declarations by the State and reduces the effectiveness of safeguards. In order to address this weakness, the authors have developed a neutron coincidence counting technique which uses the first principle point-model developed by Boehnel instead of the “known standard” method. This technique was primarily tested through simulations of 1000 g U{sub 3}O{sub 8} samples using the Monte Carlo N-Particle eXtended (MCNPX) code. The results of these simulations showed good agreement between the simulated and exact {sup 235}U sample masses.

  15. The real-time fitting of radioactive decay curves. Pt. 3. Counting during sampling

    International Nuclear Information System (INIS)

    Hartley, B.M.

    1994-01-01

    An analysis of a least-squares method for the real-time fitting of the theoretical total count function to the actual total count from radioactive decays has been given previously for the case where counting takes place after a sample is taken. The counting may be done in a number of different counting systems which distinguish between different types or energies of radiation emitted from the sample. The method would allow real-time determination of the numbers of atoms and hence activities of the individual isotopes present and has been designated the Time Evolved Least-Squares method (TELS). If the radioactivity which is to be measured exists as an aerosol or in a form where a sample is taken at a constant rate it may be possible to count during sampling and by so doing reduce the total time required to determine the activity of the individual isotopes present. The TELS method is extended here to the case where counting and the evaluation of the activity takes place concurrently with the sampling. The functions which need to be evaluated are derived and the calculations required to implement the method are discussed. As with the TELS method of counting after sampling the technique of counting during sampling and the simultaneous evaluation of activity could be achieved in real-time. Results of testing the method by computer simulation for two counting schemes for the descendants of radon are presented. ((orig.))

  16. Comparison of Drive Counts and Mark-Resight As Methods of Population Size Estimation of Highly Dense Sika Deer (Cervus nippon Populations.

    Directory of Open Access Journals (Sweden)

    Kazutaka Takeshita

    Full Text Available Assessing temporal changes in abundance indices is an important issue in the management of large herbivore populations. The drive counts method has been frequently used as a deer abundance index in mountainous regions. However, despite an inherent risk for observation errors in drive counts, which increase with deer density, evaluations of the utility of drive counts at a high deer density remain scarce. We compared the drive counts and mark-resight (MR methods in the evaluation of a highly dense sika deer population (MR estimates ranged between 11 and 53 individuals/km2 on Nakanoshima Island, Hokkaido, Japan, between 1999 and 2006. This deer population experienced two large reductions in density; approximately 200 animals in total were taken from the population through a large-scale population removal and a separate winter mass mortality event. Although the drive counts tracked temporal changes in deer abundance on the island, they overestimated the counts for all years in comparison to the MR method. Increased overestimation in drive count estimates after the winter mass mortality event may be due to a double count derived from increased deer movement and recovery of body condition secondary to the mitigation of density-dependent food limitations. Drive counts are unreliable because they are affected by unfavorable factors such as bad weather, and they are cost-prohibitive to repeat, which precludes the calculation of confidence intervals. Therefore, the use of drive counts to infer the deer abundance needs to be reconsidered.

  17. Some target assay uncertainties for passive neutron coincidence counting

    International Nuclear Information System (INIS)

    Ensslin, N.; Langner, D.G.; Menlove, H.O.; Miller, M.C.; Russo, P.A.

    1990-01-01

    This paper provides some target assay uncertainties for passive neutron coincidence counting of plutonium metal, oxide, mixed oxide, and scrap and waste. The target values are based in part on past user experience and in part on the estimated results from new coincidence counting techniques that are under development. The paper summarizes assay error sources and the new coincidence techniques, and recommends the technique that is likely to yield the lowest assay uncertainty for a given material type. These target assay uncertainties are intended to be useful for NDA instrument selection and assay variance propagation studies for both new and existing facilities. 14 refs., 3 tabs

  18. THE URINE PROTEOME FOR RADIATION BIODOSIMETRY: EFFECT OF TOTAL BODY VERSUS LOCAL KIDNEY IRRADIATION

    Science.gov (United States)

    Sharma, Mukut; Halligan, Brian D.; Wakim, Bassam T.; Savin, Virginia J.; Cohen, Eric P.; Moulder, John E.

    2009-01-01

    Victims of nuclear accidents or radiological terrorism are likely to receive varying doses of ionizing radiation inhomogeneously distributed over the body. Early biomarkers may be useful in determining organ-specific doses due to total body irradiation (TBI) or partial body irradiation. We used liquid chromatography and mass spectrometry to compare the effect of TBI and local kidney irradiation (LKI) on the rat urine proteome using a single 10 Gy dose of X-rays. Both TBI and LKI altered the urinary protein profile within 24 hours with noticeable differences in Gene Ontology categories. Some proteins including fetuin-B, tissue kallikrein, beta-glucuronidase, vitamin D-dependent calcium binding protein and chondroitin sulfate proteoglycan NG2 were detected only in the TBI group. Some other proteins including major urinary protein-1, RNA binding protein 19, neuron navigator, Dapper homolog 3, WD repeat and FYVE domain containing protein 3, sorting nexin-8, ankycorbin and aquaporin were detected only in the LKI group. Protease inhibitors and kidney proteins were more abundant (fraction of total scans) in the LKI group. Up/Uc ratio and urinary albumin abundance decreased in both TBI and LKI groups. Several markers of acute kidney injury were not detectable in either irradiated group. Present data indicate that abundance and number of proteins may follow opposite trends. These novel findings demonstrate intriguing differences between TBI and LKI, and suggest that urine proteome may be useful in determining organ-specific changes caused by partial body irradiation. PMID:20065682

  19. Total body retention of orally administered 47Ca in primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Mallette, L.E.; Sode, J.E.; Marx, S.J.; Georges, L.P.; Aurbach, G.D.

    1975-01-01

    Using a whole-body radiation detector, the total-body retention of 47 Ca 7 days after oral administration of the isotope to patients with various disorders of calcium metabolism was measured. The percent retention of 47 Ca given with 90 mg of unlabeled (carrier) calcium varied with the calcium metabolic status as follows: normals (n = 14), 33--43 percent (mean 38); primary hyperparathyroidism (n = 28), 32--74 percent (mean 52); idiopathic hypercalciuria (n = 9), 34--49 percent (mean 42); and hypercalcemia of other etiology (n = 3), 23--26 percent (mean 25). Almost half (13/28) of those with hyperparathyroidism showed a retention above 55 percent, distinguishing them from subjects with idiopathic hypercalciuria. Retention of 47 Ca correlated poorly with clinical measures of severity of hyperparathyroidism. When isotope was diluted with a smaller amount of carrier calcium (20 mg), retention was increased in normals (n = 5) to 46--54 percent (mean 50) and in hyperparathyroidism (n = 5) to 64--87 percent (mean 73). After surgical cure of hyperparathyroidism retention of isotope returned toward normal in 5 of 7 subjects. Whole-body retention of orally administered 47 Ca may prove useful in detecting hyperparathyroidism in subjects with mild hypercalcemia or hypercalciuria. (U.S.)

  20. The effect of total-body γ-irradiation on pigeons

    International Nuclear Information System (INIS)

    Gadhia, P.K.; Shah, V.C.; Desai, R.

    1979-01-01

    A study of the effects of total-body 60 Coγ radiation (200 to 2000 rad) on the common pigeon (Columba livia) has indicated a LD 50/30 of 950 +- 50 rad. There were no deaths before 6 days and the peak frequency in average deaths occurred 9 days after irradiation. Most of the birds showed small changes in activity or behaviour in the first five days. A histopathological study was made of femoral bone marrow from irradiated (1000 rad) pigeons sacrificed 1 to 18 days post-irradiation. Slight aplasia was observed on the first day after irradiation, moderately marked on the third day and extensive on the fourth and fifth days. At the end of the second week regeneration was observed as the primitive lymphocyte-like cells were differentiating into granulocytes and erythrocytes. (UK)

  1. Intake at a single, palatable buffet test meal is associated with total body fat and regional fat distribution in children.

    Science.gov (United States)

    Fearnbach, S Nicole; Thivel, David; Meyermann, Karol; Keller, Kathleen L

    2015-09-01

    Previous studies testing the relationship between short-term, ad libitum test-meal intake and body composition in children have shown inconsistent relationships. The objective of this study was to determine whether children's intake at a palatable, buffet meal was associated with body composition, assessed by dual-energy X-ray absorptiometry (DXA). A sample of 71 children (4-6 years) participated in 4 sessions where ad libitum food intake was measured. Children's intake at two of the test-meals was retained for the present analysis: a baseline meal consisting of moderately palatable foods and a highly palatable buffet including sweets, sweet-fats, and savory-fats. On the last visit, anthropometrics and DXA were assessed to determine child body composition. Children consumed significantly more calories at the palatable buffet compared to the baseline test-meal. Children's total fat-free mass was positively associated with intake at both the baseline meal and the palatable buffet meal. Total energy intake at both meals and intake of savory-fats at the palatable buffet were positively associated with children's total fat mass, total percent body fat, and percent android fat. Intake of sweet-fats was associated with child fat-free mass index. Intake of sweets was not correlated with body composition. Children's intake at a palatable test-meal, particularly of savory-fat foods, was associated with measures of total and regional body fat. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Inventory verification measurements using neutron multiplicity counting

    International Nuclear Information System (INIS)

    Ensslin, N.; Foster, L.A.; Harker, W.C.; Krick, M.S.; Langner, D.G.

    1998-01-01

    This paper describes a series of neutron multiplicity measurements of large plutonium samples at the Los Alamos Plutonium Facility. The measurements were corrected for bias caused by neutron energy spectrum shifts and nonuniform multiplication, and are compared with calorimetry/isotopics. The results show that multiplicity counting can increase measurement throughput and yield good verification results for some inventory categories. The authors provide recommendations on the future application of the technique to inventory verification

  3. Use of a pulsed neutron generator for in vivo measurement of body carbon

    International Nuclear Information System (INIS)

    Kehayias, J.J.; Ellis, K.J.; Cohn, S.H.; Yasumura, S.

    1986-01-01

    The measurement of total body fat is of importance in studies of nutritional assessment, dietary regimens, and for the management of obesity. In the past, fat has been determined either by anthropometric methods, which introduce high uncertainties, or by model-dependent estimation of fat-free tissue. The validity, however, of the different models in disease is questionable. Total body carbon measurements provide a more direct evaluation of body fat both in normal subjects and in patients. The authors present here a facility for carbon measurements without the use of a major accelerator. The same facility can be used for the measurement of other major body elements and for the evaluation of the body's compartments. Carbon is measured in vivo through neutron inelastic scattering, by detecting the 4.44 MeV gamma rays. A miniature (10 cm long) 14 MeV D-T neutron generator is used. The short half-life of the 4.44 MeV state of carbon requires detection of the gamma rays simultaneously with the 10 μs neutron pulse. Generators with low pulsing rate were found inappropriate for carbon measurement because of their low duty-cycle (high neutron output during pulse). The detection system consists of NaI(T1) detectors and fast electronics for handling the high even rate during the neutron pulse. A description of the facility and an evaluation of the technique will be presented

  4. Individual Factors Affecting Self-esteem, and Relationships Among Self-esteem, Body Mass Index, and Body Image in Patients With Schizophrenia.

    Science.gov (United States)

    Oh, EunJung; Song, EunJu; Shin, JungEun

    2017-12-01

    The purposes of this study were to identify correlations between body mass index, body image, and self-esteem in patients with schizophrenia and to analyse the specific factors affecting self-esteem. This study had a descriptive design, utilising a cross-sectional survey. Participants were patients with schizophrenia who were admitted to a mental health facility in South Korea. A total of 180 questionnaires were distributed, and an appropriate total sample size of 167 valid questionnaires was analysed. Self-esteem was significantly correlated with body image, the subscale of appearance orientation, and body areas satisfaction. However, body mass index exhibited no significant correlation with any variable. The variables found to have a significant explanatory power of 21.4% were appearance orientation and body areas satisfaction. The explanatory power of all factors was 33.6%. The self-esteem of patients with schizophrenia was influenced by body mass index and body image. The positive symptoms of schizophrenia can be controlled by medication, whereas negative symptoms can be improved through education and nursing care with medication. Thus, psychiatric nurses should develop education and care programs that contribute to the positive body image and self-esteem of patients with schizophrenia. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Mechanical component design for upgrading of whole body counter ND7500

    International Nuclear Information System (INIS)

    Norizam Saad; Mohamad Annuar Assadat Husain; Ishak Mansor

    2007-01-01

    The Whole Body Counter (WBC) ND7500 is a bed type counting system that used for measuring radionuclide in the entire human body. Malaysian Nuclear Agency has this system, which savaged from Institute of Medical Research (IMR) in 1987. This system consists of a nuclear counting system and mechanical system that totally inoperable due to its counting system failures. In April 2003, both counting system and the mechanical system were tested. The mechanical component is working properly but needs some readjustment for the bed movement while for the counting system, only detectors can work but with a poor detecting capability. During IAEA expert visits on July 2003, both detectors were verified cannot be use any longer due to poor resolution and aging factor and a single (3 x 5 x 16) inches rectangular NaI(Tl) detector was then purchased in the end of 2004 to replace (3 x 5) inches cylindrical Na(Tl) detectors. The existing shielding cannot accommodate this new (3 x 5 x 16) inches dimension and the (5 x 16) inches detecting area. Therefore, shielding modification has been done based on effective detecting area and positioning test results. A new detector's entrance and detector stage were built at the bottom shielding. A new features, which is a detectors protection also been developed for detector safety. This upgrading task successfully accomplished as from experimental the design of positioning component can make system operated easily and also can give a good results to meets user's requirements. (Author)

  6. Investigation of reduction in background counts of clover detector

    International Nuclear Information System (INIS)

    Kshetri, Ritesh

    2015-01-01

    The peak-to-total ratio can be improved by increasing the full energy peak (FEP) counts and/or by decreasing the background counts. It is notable that FEP counts will be effected by mode of operation, while background counts will be effected by both modes of operation and suppression cases. It would be interesting to know if the reduction in background is caused more by active suppression or by add back process. We introduce a simple formalism to investigate the reduction of background counts for different cases-single crystal or add back mode with active or passive suppression. A more sophisticated formalism for modeling a general composite detector had been presented in a series of six recent papers by the author

  7. BMI in relation to sperm count

    DEFF Research Database (Denmark)

    Sermondade, N; Faure, C; Fezeu, L

    2013-01-01

    BACKGROUND The global obesity epidemic has paralleled a decrease in semen quality. Yet, the association between obesity and sperm parameters remains controversial. The purpose of this report was to update the evidence on the association between BMI and sperm count through a systematic review...... with meta-analysis. METHODS A systematic review of available literature (with no language restriction) was performed to investigate the impact of BMI on sperm count. Relevant studies published until June 2012 were identified from a Pubmed and EMBASE search. We also included unpublished data (n = 717 men...... studies were included in the meta-analysis, resulting in a sample of 13 077 men from the general population and attending fertility clinics. Data were stratified according to the total sperm count as normozoospermia, oligozoospermia and azoospermia. Standardized weighted mean differences in sperm...

  8. The dosimetry of cobalt-60 γ-ray total body irradiation before bone marrow transplantation

    International Nuclear Information System (INIS)

    Dong Fan; Zhang Guiru

    1989-11-01

    The dosimetric considerations of using conventional cobalt-60 unit total body irradiation (TBI) are presented. By extending the source-to-midplane distance (SMD) to 346 cm, a 92 x 98 cm 2 rectangular field with diagonal dimension 134 cm was obtained. The results from the phantom measurements showed: (1) the effective field corresponding to an average-size patient is 25 x 25 cm 2 , and a method for estimating the effective field of human body is given; (2) the midplane doses are consistently higher than those of surfaces, but the dose ratio of midplane to surface decreases as the body thickness increases, and a significant negative correlation is existed between the dose ratio and thickness, thus a linear regression line is fitted; (3) the anterior-posterior (AP) or AP + bilateral irradiation will yield a more uniform dose distribution in the whole body than the bilateral irradiation; (4) the dose uniformity can apparently be improved by the tissue compensation, for which the technique is described

  9. Utilization of Total Joint Arthroplasty in Physician-Owned Specialty Hospitals vs Acute Care Facilities.

    Science.gov (United States)

    Chen, Antonia F; Pflug, Emily; O'Brien, Daniel; Maltenfort, Mitchell G; Parvizi, Javad

    2017-07-01

    The recent emergence of physician-owned specialty hospitals has sparked controversy about overutilization. Thus, the purpose of this study was to compare utilization patterns of total joint arthroplasty (TJA) between physician-specialty hospitals (PSHs) and acute care hospitals (ACHs). A retrospective study was conducted from January 2010 to August 2014 comparing primary TJA patients between a PSH and an ACH; 103 PSH patients were matched to 103 ACH patients by age, gender, BMI, and ASA classification with similar case distribution between facilities. All surgeons in the study operated at both hospitals and were shareholders of the PSH. Information on nonoperative treatments, and timing to the initial appointment, consent, and surgery were analyzed using univariate analysis. Nonoperative treatments before surgery were similar between hospitals (P = 1.00). The time from the initial appointment to consent was longer for PSH (P = .0001). However, the time from consent to the date of surgery (P = .04) and the timing from symptoms to initial appointment (P = .006) was shorter for PSH. The time from initial appointment to the day of surgery was similar between groups (P = .20). Patients were more likely to be consented for surgery on their first clinic visit when undergoing surgery at ACH (87 of 103, 84.4%) compared to PSH (61 of 103; 59.2%; P total knee arthroplasty (P = .001) and total hip arthroplasty patients (P = .001) at PSH. Facility ownership in PSH resulted in similar conservative treatment before TJA. The time to surgical consent after the initial appointment was longer PSH, whereas the time from consent to the date of surgery was shorter at the PSH. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Studies on the Pulse Rate, Pedometer Count and Satisfactoin Degree at Various Exercise

    OpenAIRE

    小原, 史朗

    2004-01-01

    This investigation examined whether free exercise of students became good stimulation of breathing circulation function from relation of pulse rate and pedometer count. And, I examined it on satisfaction degree after exercise. Object person was 432 man students (total of 1391) and 94 woman students (total of 472). As for relation of pulse rate and pedometer count, statistical meaning was recognized by man and women. The exercise that a pulse rate and pedometer count were high together seemed ...

  11. Establishment of Early Endpoints in Mouse Total-Body Irradiation Model.

    Directory of Open Access Journals (Sweden)

    Amory Koch

    Full Text Available Acute radiation sickness (ARS following exposure to ionizing irradiation is characterized by radiation-induced multiorgan dysfunction/failure that refers to progressive dysfunction of two or more organ systems, the etiological agent being radiation damage to cells and tissues over time. Radiation sensitivity data on humans and animals has made it possible to describe the signs associated with ARS. A mouse model of total-body irradiation (TBI has previously been developed that represents the likely scenario of exposure in the human population. Herein, we present the Mouse Intervention Scoring System (MISS developed at the Veterinary Sciences Department (VSD of the Armed Forces Radiobiology Research Institute (AFRRI to identify moribund mice and decrease the numbers of mice found dead, which is therefore a more humane refinement to death as the endpoint. Survival rates were compared to changes in body weights and temperatures in the mouse (CD2F1 male TBI model (6-14 Gy, 60Co γ-rays at 0.6 Gy min-1, which informed improvements to the Scoring System. Individual tracking of animals via implanted microchips allowed for assessment of criteria based on individuals rather than by group averages. From a total of 132 mice (92 irradiated, 51 mice were euthanized versus only four mice that were found dead (7% of non-survivors. In this case, all four mice were found dead after overnight periods between observations. Weight loss alone was indicative of imminent succumbing to radiation injury, however mice did not always become moribund within 24 hours while having weight loss >30%. Only one survivor had a weight loss of greater than 30%. Temperature significantly dropped only 2-4 days before death/euthanasia in 10 and 14 Gy animals. The score system demonstrates a significant refinement as compared to using subjective assessment of morbidity or death as the endpoint for these survival studies.

  12. Total body fat, abdominal fat, body fat distribution and surrogate markers for health related to adipocyte fatty acid-binding protein (FABP4) in children.

    Science.gov (United States)

    Dencker, Magnus; Danielson, Anton; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola

    2017-04-01

    The aim of the study was to assess possible relationships between adipocyte fatty acid-binding protein (FABP4) and total body fat (TBF), abdominal fat, body fat distribution, aerobic fitness, blood pressure, cardiac dimensions and the increase in body fat over 2 years in a community sample of children. A cross-sectional study was used in a community sample of 170 (92 boys and 78 girls) children aged 8-11 years. TBF and abdominal fat (AFM) were measured by dual-energy X-ray absorptiometry (DXA). TBF was also expressed as percentage of total body mass (BF%), and body fat distribution was calculated as AFM/TBF. Maximal oxygen uptake (VO2PEAK) was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure (SBP and DBP) and pulse pressure (PP) were measured. Echocardiography was performed. Left atrial (LA) size was measured, and left ventricular mass (LVM) was calculated. A follow-up DXA scan was available in 152 children (84 boys and 68 girls). Frozen serum samples were analyzed for FABP4. Partial correlations, with adjustment for sex, between FABP4 vs. ln TBF, ln BF%, ln AFM, AFM/TBF and VO2PEAK were (r=0.69, 0.68, 0.69, 0.49 and -0.39, pfat or change in fat distribution were not correlated.) Conclusions: Findings from this community-based cohort of young children show that increased body fat and abdominal fat, more abdominal body fat distribution, low fitness, more LVM and increased LA, increased SBP and PP were all associated with increased levels of FABP4. Increase in TBF and abdominal fat over 2 years were also associated with increased levels of FABP4.

  13. Training the staff of the regulatory body for nuclear facilities: A competency framework

    International Nuclear Information System (INIS)

    2001-11-01

    The uncertainties about the future of nuclear power in many countries, the ageing of the existing work force, and the consequential lack of interest of new professionals to engage in the nuclear field represent developments of major current international concern. The situation is compounded by the great reduction in higher education opportunities in the field of nuclear engineering and the elimination of nuclear engineering departments and research reactors in many universities and the loss of nuclear research facilities generally. Competence of regulatory staff is one of the prerequisites for the safety of nuclear facilities in the IAEA Member States. Recruitment of competent regulatory staff is difficult in many countries. Also, replacement of retiring staff members requires active efforts from the management of regulatory bodies for establishing staff qualification and training programmes. International support is needed in this domain. In 2000, the General Conference resolution GC(44)IRES/13 on education and training in radiation protection, nuclear safety and waste management urged the secretariat to 'strengthen, within available financial resources, its current efforts in this area' Several elements required for the implementation of the above resolution are already in place. A strategy paper on training in nuclear, radiation and waste safety, including specialized training courses for specific target groups, has been developed at the IAEA. The international working group on training and qualification recommended in its March meeting in 2000 that a technical document be produced on good training practices of regulatory bodies with advanced training programmes. Such a technical document would be of considerable value to many bodies. The technical document would address how training programmes for regulatory staff have been developed and implemented and include examples of training currently available. Of particular interest to regulatory agencies that have

  14. Training the staff of the regulatory body for nuclear facilities: A competency framework

    International Nuclear Information System (INIS)

    2002-11-01

    The uncertainties about the future of nuclear power in many countries, the ageing of the existing work force, and the consequential lack of interest of new professionals to engage in the nuclear field represent developments of major current international concern. The situation is compounded by the great reduction in higher education opportunities in the field of nuclear engineering and the elimination of nuclear engineering departments and research reactors in many universities and the loss of nuclear research facilities generally. Competence of regulatory staff is one of the prerequisites for the safety of nuclear facilities in the IAEA Member States. Recruitment of competent regulatory staff is difficult in many countries. Also, replacement of retiring staff members requires active efforts from the management of regulatory bodies for establishing staff qualification and training programmes. International support is needed in this domain. In 2000, the General Conference resolution GC(44)IRES/13 on education and training in radiation protection, nuclear safety and waste management urged the secretariat to 'strengthen, within available financial resources, its current efforts in this area' Several elements required for the implementation of the above resolution are already in place. A strategy paper on training in nuclear, radiation and waste safety, including specialized training courses for specific target groups, has been developed at the IAEA. The international working group on training and qualification recommended in its March meeting in 2000 that a technical document be produced on good training practices of regulatory bodies with advanced training programmes. Such a technical document would be of considerable value to many bodies. The technical document would address how training programmes for regulatory staff have been developed and implemented and include examples of training currently available. Of particular interest to regulatory agencies that have

  15. The urine proteome for radiation biodosimetry: effect of total body vs. local kidney irradiation.

    Science.gov (United States)

    Sharma, Mukut; Halligan, Brian D; Wakim, Bassam T; Savin, Virginia J; Cohen, Eric P; Moulder, John E

    2010-02-01

    Victims of nuclear accidents or radiological terrorism are likely to receive varying doses of ionizing radiation inhomogeneously distributed over the body. Early biomarkers may be useful in determining organ-specific doses due to total body irradiation (TBI) or partial body irradiation. The authors used liquid chromatography and mass spectrometry to compare the effect of TBI and local kidney irradiation (LKI) on the rat urine proteome using a single 10-Gy dose of x-rays. Both TBI and LKI altered the urinary protein profile within 24 h with noticeable differences in gene ontology categories. Some proteins, including fetuin-B, tissue kallikrein, beta-glucuronidase, vitamin D-dependent calcium binding protein and chondroitin sulfate proteoglycan NG2, were detected only in the TBI group. Some other proteins, including major urinary protein-1, RNA binding protein 19, neuron navigator, Dapper homolog 3, WD repeat and FYVE domain containing protein 3, sorting nexin-8, ankycorbin and aquaporin were detected only in the LKI group. Protease inhibitors and kidney proteins were more abundant (fraction of total scans) in the LKI group. Urine protein (Up) and creatinine (Uc) (Up/Uc) ratios and urinary albumin abundance decreased in both TBI and LKI groups. Several markers of acute kidney injury were not detectable in either irradiated group. Present data indicate that abundance and number of proteins may follow opposite trends. These novel findings demonstrate intriguing differences between TBI and LKI, and suggest that urine proteome may be useful in determining organ-specific changes caused by partial body irradiation.

  16. CD4 T lymphocyte counts in patients undergoing splenectomy during living donor liver transplantation.

    Science.gov (United States)

    Natsuda, Koji; Eguchi, Susumu; Takatsuki, Mistuhisa; Soyama, Akihiko; Hidaka, Masaaki; Hara, Takanobu; Kugiyama, Tota; Baimakhanov, Zhassulan; Ono, Shinichiro; Kitasato, Amane; Fujita, Fumihiko; Kanetaka, Kengo; Kuroki, Tamotsu

    2016-02-01

    The role of splenectomy in increasing the CD4-positive T lymphocyte counts (hereafter: CD4 counts) and the CD4 to CD8 ratio have not yet been fully investigated, especially in the case of HIV-positive patients undergoing liver transplantation (LT). The change in the total lymphocyte counts of 32 patients who underwent one-stage splenectomy with living donor (LD) LT with (n=13) or without rituximab (RTX, n=19) therapy were examined to validate our cohort of ABO-incompatible LDLT with RTX. Subsequently, perioperative changes in CD4 counts and the CD 4 to CD8 ratio were measured in 13 patients who underwent ABO-incompatible LDLT/RTX with splenectomy. (1) The administration of RTX did not significantly affect the total lymphocyte counts of patients after LDLT/splenectomy in any of the observation periods. (2) The CD4 counts were significantly higher at 2years after LDLT in comparison to the perioperative CD4 counts but not within the 3-month period (p=0.039). The CD4/CD8 ratio gradually decreased after LDLT/splenectomy under RTX treatment. An immediate increase in the CD4 counts therefore cannot be expected after LDLT with splenectomy. The total lymphocyte and CD4 counts were rather stable in the peritransplant period even in ABO incompatible LDLT with RTX. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Flow Cytometry Total Cell Counts: A Field Study Assessing Microbiological Water Quality and Growth in Unchlorinated Drinking Water Distribution Systems

    Science.gov (United States)

    Liu, G.; Van der Mark, E. J.; Verberk, J. Q. J. C.; Van Dijk, J. C.

    2013-01-01

    The objective of this study was to evaluate the application of flow cytometry total cell counts (TCCs) as a parameter to assess microbial growth in drinking water distribution systems and to determine the relationships between different parameters describing the biostability of treated water. A one-year sampling program was carried out in two distribution systems in The Netherlands. Results demonstrated that, in both systems, the biomass differences measured by ATP were not significant. TCC differences were also not significant in treatment plant 1, but decreased slightly in treatment plant 2. TCC values were found to be higher at temperatures above 15°C than at temperatures below 15°C. The correlation study of parameters describing biostability found no relationship among TCC, heterotrophic plate counts, and Aeromonas. Also no relationship was found between TCC and ATP. Some correlation was found between the subgroup of high nucleic acid content bacteria and ATP (R 2 = 0.63). Overall, the results demonstrated that TCC is a valuable parameter to assess the drinking water biological quality and regrowth; it can directly and sensitively quantify biomass, detect small changes, and can be used to determine the subgroup of active HNA bacteria that are related to ATP. PMID:23819117

  18. Flow Cytometry Total Cell Counts: A Field Study Assessing Microbiological Water Quality and Growth in Unchlorinated Drinking Water Distribution Systems

    Directory of Open Access Journals (Sweden)

    G. Liu

    2013-01-01

    Full Text Available The objective of this study was to evaluate the application of flow cytometry total cell counts (TCCs as a parameter to assess microbial growth in drinking water distribution systems and to determine the relationships between different parameters describing the biostability of treated water. A one-year sampling program was carried out in two distribution systems in The Netherlands. Results demonstrated that, in both systems, the biomass differences measured by ATP were not significant. TCC differences were also not significant in treatment plant 1, but decreased slightly in treatment plant 2. TCC values were found to be higher at temperatures above 15°C than at temperatures below 15°C. The correlation study of parameters describing biostability found no relationship among TCC, heterotrophic plate counts, and Aeromonas. Also no relationship was found between TCC and ATP. Some correlation was found between the subgroup of high nucleic acid content bacteria and ATP (R2=0.63. Overall, the results demonstrated that TCC is a valuable parameter to assess the drinking water biological quality and regrowth; it can directly and sensitively quantify biomass, detect small changes, and can be used to determine the subgroup of active HNA bacteria that are related to ATP.

  19. Genetic parameters for fecal egg count and body weight in Katahdin lambs

    Science.gov (United States)

    The objective of this study was to estimate genetic parameters for fecal egg count at weaning (WFEC) and post weaning (PWFEC), and weights at birth (BW), weaning (WW) and post weaning (PWW) in Katahdin lambs by investigating direct additive, maternal additive, maternal permanent environmental and ma...

  20. Exploring the Relationship between Skeletal Mass and Total Body Mass in Birds.

    Science.gov (United States)

    Martin-Silverstone, Elizabeth; Vincze, Orsolya; McCann, Ria; Jonsson, Carl H W; Palmer, Colin; Kaiser, Gary; Dyke, Gareth

    2015-01-01

    Total body mass (TBM) is known to be related to a number of different osteological features in vertebrates, including limb element measurements and total skeletal mass. The relationship between skeletal mass and TBM in birds has been suggested as a way of estimating the latter in cases where only the skeleton is known (e.g., fossils). This relationship has thus also been applied to other extinct vertebrates, including the non-avian pterosaurs, while other studies have used additional skeletal correlates found in modern birds to estimate TBM. However, most previous studies have used TBM compiled from the literature rather than from direct measurements, producing values from population averages rather than from individuals. Here, we report a new dataset of 487 extant birds encompassing 79 species that have skeletal mass and TBM recorded at the time of collection or preparation. We combine both historical and new data for analyses with phylogenetic control and find a similar and well-correlated relationship between skeletal mass and TBM. Thus, we confirm that TBM and skeletal mass are accurate proxies for estimating one another. We also look at other factors that may have an effect on avian body mass, including sex, ontogenetic stage, and flight mode. While data are well-correlated in all cases, phylogeny is a major control on TBM in birds strongly suggesting that this relationship is not appropriate for estimating the total mass of taxa outside of crown birds, Neornithes (e.g., non-avian dinosaurs, pterosaurs). Data also reveal large variability in both bird skeletal and TBM within single species; caution should thus be applied when using published mass to test direct correlations with skeletal mass and bone lengths.

  1. Somatic cell counts in bulk milk and their importance for milk processing

    Science.gov (United States)

    Savić, N. R.; Mikulec, D. P.; Radovanović, R. S.

    2017-09-01

    Bulk tank milk somatic cell counts are the indicator of the mammary gland health in the dairy herds and may be regarded as an indirect measure of milk quality. Elevated somatic cell counts are correlated with changes in milk composition The aim of this study was to assess the somatic cell counts that significantly affect the quality of milk and dairy products. We examined the somatic cell counts in bulk tank milk samples from 38 farms during the period of 6 months, from December to the May of the next year. The flow cytometry, Fossomatic was used for determination of somatic cell counts. In the same samples content of total proteins and lactose was determined by Milcoscan. Our results showed that average values for bulk tank milk samples were 273,605/ml from morning milking and 292,895/ml from evening milking. The average values for total proteins content from morning and evening milking are 3,31 and 3,34%, respectively. The average values for lactose content from morning and evening milking are 4,56 and 4,63%, respectively. The highest somatic cell count (516,000/ml) was detected in bulk tank milk sample from evening milk in the Winter and the lowest content of lactose was 4,46%. Our results showed that obtained values for bulk tank milk somatic cell counts did not significantly affected the content of total proteins and lactose.

  2. Associations between access to recreational physical activity facilities and body mass index in Scottish adults.

    Science.gov (United States)

    Ellaway, Anne; Lamb, Karen E; Ferguson, Neil S; Ogilvie, David

    2016-08-09

    The aim of this country-wide study was to link individual health and behavioural data with area-level spatial data to examine whether the body mass index (BMI) of adults was associated with access to recreational physical activity (PA) facilities by different modes of transport (bus, car, walking, cycling) and the extent to which any associations were mediated by PA participation. Data on individual objectively-measured BMI, PA (number of days of (a) ≥20 min of moderate-to-vigorous PA, and (b) ≥15 min of sport or exercise, in previous 4 weeks), and socio-demographic characteristics were obtained from a nationally representative sample of 6365 adults. The number of accessible PA facilities per 1,000 individuals in each small area (data zones) was obtained by mapping a representative list of all fixed PA facilities throughout mainland Scotland. A novel transport network was developed for the whole country, and routes on foot, by bike, by car and by bus from the weighted population centroid of each data zone to each facility were calculated. Separate multilevel models were fitted to examine associations between BMI and each of the 24 measures of accessibility of PA facilities and BMI, adjusting for age, gender, longstanding illness, car availability, social class, dietary quality and urban/rural classification. We found associations (p < 0.05) between BMI and 7 of the 24 accessibility measures, with mean BMI decreasing with increasing accessibility of facilities-for example, an estimated decrease of 0.015 BMI units per additional facility within a 20-min walk (p = 0.02). None of these accessibility measures were found to be associated with PA participation. Our national study has shown that some measures of the accessibility of PA facilities by different modes of transport (particularly by walking and cycling) were associated with BMI; but PA participation, as measured here, did not appear to play a part in this relationship. Understanding the multi

  3. Design, fabrication and commissioning of motorized scanning bed mechanism for shadow shield whole body counting system

    International Nuclear Information System (INIS)

    Arun, B.; Varalakshimi, S.; Manohari, M.; Mathiyarasu, R.

    2012-01-01

    A new scanning bed mechanism for shadow shield counting system is designed, fabricated and commissioned at RSD, IGCAR. The present motorized scanning bed mechanism has varying scan speeds, state of art limit sensors, smooth bed movement, touch screen based software controlled operation parameters with UPS power back-up. In view of the improved personnel safety the entire system has been designed to operate with low voltage power supply (24V). The evaluation demonstrated that the incorporation of the new motorized scanning mechanism has not affected the counting performance of the shadow shield wholebody counting system. (author)

  4. Spontaneous resolution of posterior ankle joint loose bodies after total ankle replacement: A case report.

    Science.gov (United States)

    Lee, Raymond P; Cheng, Sally H S

    2017-06-01

    Late stage ankle osteoarthritis often presents with debilitating pain. It is common to find osteophytes and loose body formation around the joint. Total ankle arthroplasty can preserve joint mobility and pain relieve for such patient. However, when trying to remove the osteophytes and loose bodies at the posterior ankle joint, there is risk of damaging posterior structures such as the neurovascular bundle during the procedure. We are presenting a case where the posterior loose bodies remained untouched during the operation, and patient showed spontaneous resolution of the lesions with time. Patient enjoyed good function outcome after the surgery. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  5. BODY COMPOSITION OF A MILITARY POPULATION FT. CARSON 1963. I. BODY DENSITY, FAT, AND POTASSIUM 40.

    Science.gov (United States)

    Body volumes were measured on 97 soldiers between the ages of 17 - 52 years by water displacement volumetry and corrected for respiratory gas by a...Effective ranking of body fat burden of populations was demonstrated by body volumetry and age differences were noted from potassium 40 counting. A

  6. Serum albumin and total lymphocyte count as predictors of outcome in hip fractures.

    LENUS (Irish Health Repository)

    O'Daly, Brendan J

    2012-02-01

    BACKGROUND & AIMS: Hip fractures are a significant cause of mortality and morbidity in the elderly. Malnutrition is a significant contributor to this, however no consensus exists as to the detection or management of this condition. We hypothesise that results of admission serum albumin and total lymphocyte count (TLC), as markers of Protein Energy Malnutrition (PEM) can help predict clinical outcome in hip fracture patients aged over 60 years. METHODS: This retrospective study evaluated the nutritional status of patients with hip fractures using albumin and TLC assays and analysed their prognostic relevance. Clinical outcome parameters studied were delay to operation, duration of in-patient stay, re-admission and in-patient, 3- and 12-month mortality. RESULTS: Four hundred and fifteen hip fracture patients were evaluated. Survival data were available for 377 patients at 12 months. In-hospital mortality for PEM patients was 9.8%, compared with 0% for patients without. Patients with PEM had a higher 12-month mortality compared to patients who had normal values of both laboratory parameters (Odds Ratio 4.6; 95% CI: 1.0-21.3). Serum albumin (Hazard Ratio 0.932, 95% CI: 0.9-1.0) and age (Hazard Ratio 1.04, 95% CI: 1.0-1.1) were found to be significant independent prognostic factors of mortality by Cox regression analysis. CONCLUSIONS: These results highlight the relevance of assessing the nutritional status of patients with hip fractures at the time of admission and emphasises the correlation between PEM and outcome in these patients.

  7. Patterns of patient specific dosimetry in total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Akino, Yuichi [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana 46202 (United States); Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871 (Japan); McMullen, Kevin P.; Das, Indra J. [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana 46202 (United States)

    2013-04-15

    Purpose: Total body irradiation (TBI) has been used for bone marrow transplant for hematologic and immune deficiency conditions. The goal of TBI is to deliver a homogeneous dose to the entire body, with a generally accepted range of dose uniformity being within {+-}10% of the prescribed dose. The moving table technique for TBI could make dose uniform in whole body by adjusting couch speed. However, it is difficult to accurately estimate the actual dose by calculation and hence in vivo dosimetry (IVD) is routinely performed. Here, the authors present patterns of patient-specific IVD in 161 TBI patients treated at our institution. Methods: Cobalt-60 teletherapy unit (Model C9 Cobalt-60 teletherapy unit, Picker X-ray Corporation) with customized moving bed (SITI Industrial Products, Inc., Fishers, IN) were used for TBI treatment. During treatment, OneDose{sup TM} (Sicel Technology, NC) Metal Oxide-silicon Semiconductor Field Effect Transistor detectors were placed at patient body surface; both entrance and exit side of the beam at patient head, neck, mediastinum, umbilicus, and knee to estimate midplane dose. When large differences (>10%) between the prescribed and measured dose were observed, dose delivery was corrected for subsequent fractions by the adjustment of couch speed and/or bolus placement. Under IRB exempt status, the authors retrospectively analyzed the treatment records of 161 patients who received TBI treatment between 2006 and 2011. Results: Across the entire cohort, the median {+-} SD (range) percent variance between calculated and measured dose for head, neck, mediastinum, umbilicus, and knee was -2.3 {+-} 10.2% (-66.2 to +35.3), 1.1 {+-} 11.5% (-62.2 to +40.3), -1.9 {+-} 9.5% (-66.4 to +46.6), -1.1 {+-} 7.2% (-35.2 to +42.9), and 3.4 {+-} 12.2% (-47.9 to +108.5), respectively. More than half of treatments were within {+-}10% of the prescribed dose for all anatomical regions. For 80% of treatments (10%-90%), dose at the umbilicus was within {+-}10

  8. Discriminative ability of total body bone-mineral measured by dual photon absorptiometry

    International Nuclear Information System (INIS)

    Gotfredsen, A.; Poedenphant, J.; Nilas, L.; Christiansen, C.

    1989-01-01

    We investigated the descriminative ability of total body bone-mineral expressed as the total body bone-density (TBBD) measured by dual photon absorptiometry (DPA) in 79 healthy premenopausal women, 27 healthy postmenopausal women, and 120 female osteoporotic fracture patients presenting with either Colles' fracture, vertebral fracture or femoral neck-fracture. TBBD was compared to the bone-mineral density of the lumbar spine (BMD spine ) also measured by DPA, and to the bone-mineral content of the forearms (BMC forearm ) measured by single photon absorptiometry (SPA). TBBD, BMD spine and BMC forearm showed that all the fracture patient groups had significantly reduced bone-mass. Using receiver operating characteristic (ROC) analysis, we found that TBBD had a tendency towards better discriminative ability than BMD spine or BMC forearm with regard to the discrimination between healthy premenopausal women and the three types of osteoporotic fractures. BMC forearm had an intermediate position, whereas BMD spine had the smallest discriminative ability. TBBD also discriminated better between healthy postmenopausal women and hip-fracture patients than BMD spine or BMC forearm , whereas there was no significant difference between the three methods regarding the discrimination between the healthy postmenopausal women and the Colles' and spinal fracture patients. We conclude that the TBBD measurement by DPA has a discriminative potential which is better than the local spine or forearm measurements. (author)

  9. Development of realistic chest phantom for calibration of in-vivo plutonium counting facilities

    International Nuclear Information System (INIS)

    Shirotani, Takashi

    1987-06-01

    We have developed realistic chest phantom with removable model organs. The phantom is a torso and is terminated just above the femoral region. Tissue equivalent materials used in the phantom have been made of polyurethane with different amounts of ester of phosphoric acid, in order to simulate human soft tissues such as muscle, muscle-adipose mixtures and cartilage. Lung simulant has been made of foamed polyurethane. Capsulized small sources can be inserted into the holes, drilled in each sliced section of the model organ. Counting efficiencies, obtained with a pair of 12 cm diameter phoswich detectors set above the phantom chest, are 0.195 cpm/nCi for Pu-239 and 44.07 cpm/nCi for Am-241, respectively. The results agree well with efficiencies obtained with IAEA-Phantom. We conclude that the phantom can be used as a standard phantom for the calibration of Pu chest counting equipment. (author)

  10. Total body fat, proinflammatory cytokines and insulin resistance in Indian subjects

    International Nuclear Information System (INIS)

    Yajnik, C.S.; Lubree, H.G.; Rege, S.S.; Bhat, D.S.; Raut, K.N.; Panchanadikar, A.S.; Joglekar, C.B.; Naik, S.S.; Shetty, P.; Yudkin, J.; Kurpad, A.V.

    2002-01-01

    We studied cardiovascular risk factors in 30 to 50 year old Indian men in three geographical locations (rural, urban slums and urban middle class) in relation to their body fat. A total of 1,222 subjects, selected by stratified random sampling were screened: 39 reported diabetic or hypertensive. Of the remaining subjects 600 were randomly selected for further testing. This is a report 441 men studied (149 rural, 142 slums, 150 urban middle class). The mean age of these men was 38 y rural, 38 y urban slums, 41 y urban middle class, mean BMI 21.0 kg/m 2 , 22.3 kg/m 2 and 24.3 kg/m 2 respectively, mean body fat percent by bio-impedance 20.4%, 22.5% and 30.4% and by Deuterated water was 19.9%, 21.6% and 27.2% respectively. A 75 g oral glucose tolerance test (WHO 1985) showed no diabetes in rural subjects, while 4% urban slum dwellers and 10 in urban middle class were diabetic; 9% rural men had IGT, compared to 12% in urban slums and 20% in urban middle class. Hypertension (blood pressure ≥ 140/90 mm Bg) was present in 2% rural men, 4% in urban slums and in 10% men in urban middle class. Mean plasma cholesterol concentration was 148 mg% in rural, 53 mg% in urban slums and 64 mg% in urban middle class, mean plasma triglyceride concentrations were 82 mg%, 95 mg% and 108 mg% respectively. All cardiovascular risk factors were strongly related to measures of obesity (body fat % and waist hip ratio). On multivariate analysis 2h plasma glucose (OGTT) concentration and blood pressure were additionally related to geographical location (urban middle class>slums>rural). Our results suggest that urbanisation increases the risk of glucose intolerance and hypertension independent of the body fat percent or its central distribution. This suggests there may he additional environmental factors in the urban environment increasing the risk of diabetes over and above the effect of body fat. (author)

  11. Total body fat, proinflammatory cytokines and insulin resistance in Indian subjects

    Energy Technology Data Exchange (ETDEWEB)

    Yajnik, C S; Lubree, H G; Rege, S S; Bhat, D S; Raut, K N; Panchanadikar, A S; Joglekar, C B; Naik, S S [Diabetest Unit, KEM Hospital Resarch Centre, Pune (India); Shetty, P [London School of Hygiene and Tropical Medicine, London (United Kingdom); Yudkin, J [International Health and Medical Education Centre, UCL, London (United Kingdom); Kurpad, A V [St. John' s Medical College, Bangalore (India)

    2002-07-01

    We studied cardiovascular risk factors in 30 to 50 year old Indian men in three geographical locations (rural, urban slums and urban middle class) in relation to their body fat. A total of 1,222 subjects, selected by stratified random sampling were screened: 39 reported diabetic or hypertensive. Of the remaining subjects 600 were randomly selected for further testing. This is a report 441 men studied (149 rural, 142 slums, 150 urban middle class). The mean age of these men was 38 y rural, 38 y urban slums, 41 y urban middle class, mean BMI 21.0 kg/m{sup 2}, 22.3 kg/m{sup 2} and 24.3 kg/m{sup 2} respectively, mean body fat percent by bio-impedance 20.4%, 22.5% and 30.4% and by Deuterated water was 19.9%, 21.6% and 27.2% respectively. A 75 g oral glucose tolerance test (WHO 1985) showed no diabetes in rural subjects, while 4% urban slum dwellers and 10 in urban middle class were diabetic; 9% rural men had IGT, compared to 12% in urban slums and 20% in urban middle class. Hypertension (blood pressure {>=} 140/90 mm Bg) was present in 2% rural men, 4% in urban slums and in 10% men in urban middle class. Mean plasma cholesterol concentration was 148 mg% in rural, 53 mg% in urban slums and 64 mg% in urban middle class, mean plasma triglyceride concentrations were 82 mg%, 95 mg% and 108 mg% respectively. All cardiovascular risk factors were strongly related to measures of obesity (body fat % and waist hip ratio). On multivariate analysis 2h plasma glucose (OGTT) concentration and blood pressure were additionally related to geographical location (urban middle class>slums>rural). Our results suggest that urbanisation increases the risk of glucose intolerance and hypertension independent of the body fat percent or its central distribution. This suggests there may he additional environmental factors in the urban environment increasing the risk of diabetes over and above the effect of body fat. (author)

  12. Creatine Supplementation Increases Total Body Water in Soccer Players: a Deuterium Oxide Dilution Study.

    Science.gov (United States)

    Deminice, R; Rosa, F T; Pfrimer, K; Ferrioli, E; Jordao, A A; Freitas, E

    2016-02-01

    This study aimed to evaluate changes in total body water (TBW) in soccer athletes using a deuterium oxide dilution method and bioelectrical impedance (BIA) formulas after 7 days of creatine supplementation. In a double-blind controlled manner, 13 healthy (under-20) soccer players were divided randomly in 2 supplementation groups: Placebo (Pla, n=6) and creatine supplementation (CR, n=7). Before and after the supplementation period (0.3 g/kg/d during 7 days), TBW was determined by deuterium oxide dilution and BIA methods. 7 days of creatine supplementation lead to a large increase in TBW (2.3±1.0 L) determined by deuterium oxide dilution, and a small but significant increase in total body weight (1.0±0.4 kg) in Cr group compared to Pla. The Pla group did not experience any significant changes in TBW or body weight. Although 5 of 6 BIA equations were sensitive to determine TBW changes induced by creatine supplementation, the Kushner et al. 16 method presented the best concordance levels when compared to deuterium dilution method. In conclusion, 7-days of creatine supplementation increased TBW determined by deuterium oxide dilution or BIA formulas. BIA can be useful to determine TBW changes promoted by creatine supplementation in soccer athletes, with special concern for formula choice. © Georg Thieme Verlag KG Stuttgart · New York.

  13. The development and medical applications of a simple facility for partial body in vivo neutron activation analysis using californium-252 sources

    International Nuclear Information System (INIS)

    Boddy, K.

    1978-11-01

    A simple and cheap facility for partial body neutron activation analysis has been designed, based on the use of two 100 μg 252 Cf neutron sources. The results reported show that calcium can be measured in parts of the body such as the tibia with a precision as good as +- 1.6 % for a radiation dose of 2 rem. The uniformity of the thermal neutron flux density is better than +- 3 % over 10 cm. Some applications of this irradiation facility for studies of trace elements, in particular cadmium in liver and aluminium in liver or brain, have also been explored. However, the sensitivity attainable is not yet sufficient for the study of normal levels, but could be of interest in toxicological investigations

  14. Bromide space, total body water, and sick cell syndrome

    International Nuclear Information System (INIS)

    Schober, O.; Hundeshagen, H.; Lehr, L.

    1982-01-01

    Displacements of the bromide space (Br-82-C, as a marker for the extracellular fluid compartment) are caused by an enhanced anatomical space and/or increased permeability of cells to bromide. The ratio Br-82-C: total body water (TBW) was evaluated to be 0.83 +- 0.17 in critically ill patients (n = 38) compared with the normal value of 0.46 +- 0.04 (n = 10). Because of normal TBW in critically ill patients (TBW = 505 +- 68 ml/kg), an increased bromide penetration into cells seems to be responsible for the enlarged ratio Br-82-C: TBW. Taking into consideration measurements in patients with malabsorption (Br-82-C: TBW = 0.56 +- 0.13; n = 13) and carcinoma of the rectum and colon (Br-82-C: TBW = 0.66 +- 0.24; n = 18) we think that the bromide space is a good measurement of the effective extracellular water. (orig.)

  15. Hyperfractionated total body irradiation for T-depleted HLA identical bone marrow transplants

    International Nuclear Information System (INIS)

    Latini, P.; Checcaglini, F.; Maranzano, E.; Aristei, C.; Panizza, B.M.; Gobbi, G.; Raymondi, C.; Aversa, F.; Martelli, M.F.

    1988-01-01

    Twenty patients suffering from malignant hemopathies (mean age 31.7 years) were given hyperfractionated total body irradiation (TBI) as conditioning for T-depleted HLA identical allogeneic bone marrow transplantation. At an average of 12 months (range of 4.5-22 months) follow-up there were two cases of early death and two cases (11%) of rejection. There were no cases of acute or chronic graft versus host disease nor cases of interstitial pneumonitis. The average time for durable engraftment was 22 days. Disease-free survival at 12 months was 65%. To improve the results and further reduce the percent of rejection, the authors propose intensifying the immunosuppressive conditioning by increasing the cyclophosphamide dose and that of TBI so that a total dose of 1560 cGy is reached. 35 refs.; 1 figure

  16. Control in personnel exposure at HIRUP facility during the period 2006-2010

    International Nuclear Information System (INIS)

    Ojha, Shashikala; Suman, Santosh Kumar; Murali, S.

    2012-01-01

    HIRUP facility is designed to handle MCi of 60 Co, fabrication of sealed source, is carried out in hot cell. The design safety features allow the handling of sealed sources and other gamma emitters under suitable containment systems. The NP Unit of the facility provides personnel monitoring programmes viz., TLD/DRD monitoring for the radiation workers. 60 Co and other gamma emitters pose mainly external hazard during the handling of sealed source in hot cell. TLD is processed to assess the external exposure of personnel. Air activity and gross bg contamination at the work place is periodically monitored and reported. The TLD users of HIRUP are periodically referred for internal monitoring - whole body counting and bio-assay to estimate internal exposure. There is no reported internal exposure so far. Personnel from IAD and BRIT facility are provided with personnel monitoring coverage by HP Unit; the TLD is issued with respective institution no. as - 0283, 4288. Each person gets identified by individual TLD number, renewed TLD issue on quarterly service period. Based on job requirement such as handling of high activity, additional Wrist TLDs are provided. The used TLD of IAD and BRIT are sent for processing. The dose report obtained, enlists personnel exposure details. HP Unit does the report making to the concerned agencies enlisting the operational status, total occupational exposure of the facility (person mSv), average exposure (mSv) and few other details. Details of exposure for 2006 - 2010 (non-zero exposure cases), indicate that for IAD collective exposure got reduced by 78.5 %, average exposure got reduced by 62.6 %; for BRIT collective exposure got reduced by 58.2 %, average exposure got reduced by 46.8 %, at HIRUP facility. There is a decreasing trend in personnel exposure over the period 2006-2010, is due to HP safety protocol, on job HP surveillance and related safety measures. The personnel exposure is controlled as per ALARA, decreasing trend in the

  17. Lower white blood cell counts in elite athletes training for highly aerobic sports.

    Science.gov (United States)

    Horn, P L; Pyne, D B; Hopkins, W G; Barnes, C J

    2010-11-01

    White cell counts at rest might be lower in athletes participating in selected endurance-type sports. Here, we analysed blood tests of elite athletes collected over a 10-year period. Reference ranges were established for 14 female and 14 male sports involving 3,679 samples from 937 females and 4,654 samples from 1,310 males. Total white blood cell counts and counts of neutrophils, lymphocytes and monocytes were quantified. Each sport was scaled (1-5) for its perceived metabolic stress (aerobic-anaerobic) and mechanical stress (concentric-eccentric) by 13 sports physiologists. Substantially lower total white cell and neutrophil counts were observed in aerobic sports of cycling and triathlon (~16% of test results below the normal reference range) compared with team or skill-based sports such as water polo, cricket and volleyball. Mechanical stress of sports had less effect on the distribution of cell counts. The lower white cell counts in athletes in aerobic sports probably represent an adaptive response, not underlying pathology.

  18. Branched-chain amino acid-enriched nutrient increases blood platelet count in patients after endoscopic injection sclerotherapy.

    Science.gov (United States)

    Furuichi, Yoshihiro; Imai, Yasuharu; Miyata, Yuki; Sugimoto, Katsutoshi; Sano, Takatomo; Taira, Junichi; Kojima, Mayumi; Kobayashi, Yoshiyuki; Nakamura, Ikuo; Moriyasu, Fuminori

    2016-10-01

    Protein and energy malnutrition is a severe problem for patients with liver cirrhosis (LC) and fasting often induces starvation which is a vitally important outcome. Dietary restriction is essential for endoscopic injection sclerotherapy (EIS) in patients with risky esophageal varices, thereby creating the possible exacerbation of nutritional state and inducing liver dysfunction. Whether EIS induces nutritional deficiency in LC patients and the effects of branched-chain amino acid (BCAA)-enriched nutrient are prospectively investigated. A total of 61 LC patients were randomly divided into an EIS monotherapy group (non-BCAA group, n = 31) and an EIS combined with BCAA therapy group (n = 30). Platelet count, blood chemistry and somatometry values were prospectively measured at five time points. The platelet counts before treatment were at the same level in both groups (P = 0.72). Three months after treatment, the counts decreased in the non-BCAA group; however, they increased in the BCAA group (P = 0.019). Body mass index, triceps skin fold thickness and arm muscle circumference significantly decreased in both groups. The BCAA and tyrosine ratio value increased only in the BCAA group (P BCAA group (P BCAA. Administration of BCAA had some effect in maintaining the nutritional state, and may improve the platelet count. Taking a greater amount of nutrients and shorter dietary restriction period or hospitalization was desirable. © 2016 The Japan Society of Hepatology.

  19. Familial Melanoma Associated with Li-Fraumeni Syndrome and Atypical Mole Syndrome: Total-body Digital Photography, Dermoscopy and Confocal Microscopy.

    Science.gov (United States)

    Giavedoni, Priscila; Ririe, Marnie; Carrera, Cristina; Puig, Susana; Malvehy, Josep

    2017-06-09

    Li-Fraumeni syndrome (LFS) is a rare autosomal dominant disorder caused by a mutation in the p53 gene. Melanoma is considered to be a rare, controversial component of LFS. The aim of this study is to describe the utility of systematic screening for melanoma in patients with LFS and atypical mole syndrome. Two 28-year-old identical twin sisters with LFS and atypical moles were monitored by physical examination, total-body digital photography and dermoscopy be-tween 2006 and 2014. A total of 117, predominantly dark-brown, reticular naevi were identified on case 1 and 105 on case 2. Excisions were performed during the evaluation period of 1 in-situ melanoma and 3 basal cell carcinomas in case 1, and 1 in-situ melanoma and 1 early invasive melanoma in case 2. The remaining melanocytic lesions in both patients were stable during follow-up. The 3 melanomas were new atypical lesions detected with total-body photography and dermoscopy. In conclusion, monitoring LFS patients with total-body photography and dermoscopy may be useful to detect early melanoma.

  20. Risk factors associated with bulk tank standard plate count, bulk tank coliform count, and the presence of Staphylococcus aureus on organic and conventional dairy farms in the United States.

    Science.gov (United States)

    Cicconi-Hogan, K M; Gamroth, M; Richert, R; Ruegg, P L; Stiglbauer, K E; Schukken, Y H

    2013-01-01

    The purpose of this study was to assess the association of bulk tank milk standard plate counts, bulk tank coliform counts (CC), and the presence of Staphylococcus aureus in bulk tank milk with various management and farm characteristics on organic and conventional dairy farms throughout New York, Wisconsin, and Oregon. Data from size-matched organic farms (n=192), conventional nongrazing farms (n=64), and conventional grazing farms (n=36) were collected at a single visit for each farm. Of the 292 farms visited, 290 bulk tank milk samples were collected. Statistical models were created using data from all herds in the study, as well as exclusively for the organic subset of herds. Because of incomplete data, 267 of 290 herds were analyzed for total herd modeling, and 173 of 190 organic herds were analyzed for the organic herd modeling. Overall, more bulk tanks from organic farms had Staph. aureus cultured from them (62% of organic herds, 42% conventional nongrazing herds, and 43% of conventional grazing herds), whereas fewer organic herds had a high CC, defined as ≥50 cfu/mL, than conventional farms in the study. A high standard plate count (×1,000 cfu/mL) was associated with decreased body condition score of adult cows and decreased milk production in both models. Several variables were significant only in the model created using all herds or only in organic herds. The presence of Staph. aureus in the bulk tank milk was associated with fewer people treating mastitis, increased age of housing, and a higher percentage of cows with 3 or fewer teats in both the organic and total herd models. The Staph. aureus total herd model also showed a relationship with fewer first-lactation animals, higher hock scores, and less use of automatic takeoffs at milking. High bulk tank CC was related to feeding a total mixed ration and using natural service in nonlactating heifers in both models. Overall, attentive management and use of outside resources were useful with regard to CC

  1. Method of quantification of bone scintigraphy using technetium labelled stannous pyrophosphate. Results concerning 882 whole-body scintigraphy

    International Nuclear Information System (INIS)

    Chedeville, Rene.

    1976-01-01

    Considerable progress was made in isotope bone imaging with strontium 85 after the principle of quantification was introduced by Rosenthall in 1965. In 1971, Subramanian and McAffee reported that excellent visualization could be obtained with polyphosphates labelled with sup(99m)Tc. In the present study, imaging was performed 4 hours after injection of sup(99m)Tc pyrophosphate. An Elscint dual head wole body scanner and a VDP 2 off-line calculator were used. Counts were collected over selected regions of interest, each measuring 4.5 x 3.5 cm, and over the whole body. After checking reproducibility by double counting (SD of the mean = 15%), two methods of quantification were studied, the counts being expressed as: the ratio of the number of counts in the bone segment to the number of counts in the knee, the ratio of the number of counts in the bone segment/the number of counts in the whole body. In these operations, the whole body count was multiplied by 2.10 -3 in order to have a ratio whole body count.2.10 -3 /knee = 1. The ratios calculated from the different bone diseases under study were then compared [fr

  2. Longitudinal measurements of total body water and body composition in healthy volunteers by online breath deuterium measurement and other near-subject methods

    Czech Academy of Sciences Publication Activity Database

    Engel, B.; Španěl, Patrik; Smith, D.; Diskin, A. M.; Davis, S. J.

    2005-01-01

    Roč. 2, č. 3 (2005), s. 99-106 ISSN 1479-456X R&D Projects: GA ČR(CZ) GA203/00/0632 Institutional research plan: CEZ:AV0Z40400503 Keywords : total body water * deuterium isotope dilution * FA-MS * bio-impendance Subject RIV: CF - Physical ; Theoretical Chemistry

  3. Straw blood cell count, growth, inhibition and comparison to apoptotic bodies

    Directory of Open Access Journals (Sweden)

    Tomkins Jeffrey P

    2008-05-01

    Full Text Available Abstract Background Mammalian cells transform into individual tubular straw cells naturally in tissues and in response to desiccation related stress in vitro. The transformation event is characterized by a dramatic cellular deformation process which includes: condensation of certain cellular materials into a much smaller tubular structure, synthesis of a tubular wall and growth of filamentous extensions. This study continues the characterization of straw cells in blood, as well as the mechanisms of tubular transformation in response to stress; with specific emphasis placed on investigating whether tubular transformation shares the same signaling pathway as apoptosis. Results There are approximately 100 billion, unconventional, tubular straw cells in human blood at any given time. The straw blood cell count (SBC is 45 million/ml, which accounts for 6.9% of the bloods dry weight. Straw cells originating from the lungs, liver and lymphocytes have varying nodules, hairiness and dimensions. Lipid profiling reveals severe disruption of the plasma membrane in CACO cells during transformation. The growth rates for the elongation of filaments and enlargement of rabbit straw cells is 0.6~1.1 (μm/hr and 3.8 (μm3/hr, respectively. Studies using apoptosis inhibitors and a tubular transformation inhibitor in CACO2 cells and in mice suggested apoptosis produced apoptotic bodies are mediated differently than tubular transformation produced straw cells. A single dose of 0.01 mg/kg/day of p38 MAPK inhibitor in wild type mice results in a 30% reduction in the SBC. In 9 domestic animals SBC appears to correlate inversely with an animal's average lifespan (R2 = 0.7. Conclusion Straw cells are observed residing in the mammalian blood with large quantities. Production of SBC appears to be constant for a given animal and may involve a stress-inducible protein kinase (P38 MAPK. Tubular transformation is a programmed cell survival process that diverges from apoptosis

  4. Polycystic ovary syndrome and the peripheral blood white cell count.

    LENUS (Irish Health Repository)

    Herlihy, A C

    2012-02-01

    This retrospective cross-sectional study examined if the white cell count (WCC) is increased in women with polycystic ovary syndrome (PCOS) and if so, is it due to PCOS or to the associated obesity? Body mass index (BMI) was calculated and body composition was measured using bioelectrical impedance analysis. Of the 113 women studied, 36 had PCOS and 77 did not. The mean WCC was higher in the PCOS group compared with the non-PCOS group (8.9 x 10(9)\\/l vs 7.4 x 10(9)\\/l p = 0.002). This increase was due to a higher neutrophil count (5.6 x 10(9)\\/l vs 4.3 x 10(9)\\/l; p = 0.003). There was a leucocytosis (WCC >11 x 10(9)\\/l) present in 19% of the PCOS group compared with 1% in the non-PCOS group (p < 0.001). The neutrophil count was abnormally high (>7.7 x 10(9)\\/l) in 14% of the PCOS group compared with 4% in the non-PCOS group (p < 0.001). On regression analysis, however, the only independent variable which explained both the increased WCC and the increased neutrophil count was PCOS. We found that PCOS is associated with an increased WCC due to increased neutrophils, which supports the evidence that PCOS is associated with low-grade inflammation. The increase appears to be due to the underlying PCOS, and not to the increased adiposity associated with PCOS.

  5. Calibration Human Voxel Phantoms for In Vivo Measurement of ''241 Am in Bone at the Whole Body Counter Facility of CIEMAT

    Energy Technology Data Exchange (ETDEWEB)

    Moraleda, M.; Lopez, M. A.; Gomez Ros, J. M.; Navarro, T.; Navarro, J. F.

    2002-07-01

    The Whole Body Counting facility of CIEMAT is capable of carrying out In-Vivo measurements of radionuclides emitting X-rays and low energy gamma radiation internally deposited in the body. The system to use for this purpose consists of flour Low energy Germanium (LeGe) Camberra detectors working in the energy range from 10 to 1000 keV. Physical phantoms with a known contamination in the organ of interest are normally used for the calibration of the LEGe detection system. In this document we present a calibration method using the Monte Carlo technique (MCNP4C) over a voxel phantom obtained from a computerized tomography of a real human head. The phantom consists of 104017 (43x59x41) cubic voxels, 4 mn on each side, os specific tissues, but for this simulation only two types are taken into account: adipose tissue and hard bone. The skull is supposed to be contaminated with ''241 Am and the trajectories of the photons are simulated till they reach the germanium detectors. The detectors were also simulated in detail to obtain a good agreement with the reality. In order to verify the accuracy of this procedure to reproduce the experiments, the MCNP results are compared with laboratory measurements of a head phantom simulating an internal contamination of 1000 Bq of ''241 Am deposited in bone. Different relative positions source-detector were tried to look for the best countring geometry for measurement of a contaminated skull. Efficiency values are obtained and compared, resulting in the validation of the mathematical method for the assessment of internal contamination of American deposited in skeleton. (Author) 16 refs.

  6. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  7. Total body irradiation and marrow transplantation for acute leukaemia. The Royal Marsden Hospital experience

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, A; Barrett, A J; Powles, R L [Institute of Cancer Research, Sutton (UK). Surrey Branch; Royal Marsden Hospital, London (UK))

    1979-06-01

    The experience with total body irradiation at the Royal Marsden Hospital is described for an elective program of transplantation in patients with acute myeloid leukaemia (AML) in first remission. Dose rate appears to be a critical factor in the reduction of radiation-associated damage and careful monitoring of the actual dose distribution and dose received is mandatory.

  8. The effects of protein dietary supplementation on fecal egg counts and hematological parameters in goat kids with subclinical nematodosis

    Directory of Open Access Journals (Sweden)

    Priyanka Konwar

    2015-11-01

    Full Text Available Aim: The aim of the present study was to assess the effect of dietary supplementation with different levels of protein on fecal egg counts and hematological parameters in goat kids with subclinical nematodosis under semi-intensive condition. Materials and Methods: 20 goat kids (3-5 months old with an average body weight of 8.90 kg were randomly allocated to four groups: T1, served as a negative control, without receiving concentrate feed, and T2, T3, and T4 that received concentrate feed containing 16, 20, and 24% digestible crude protein, respectively. The experiment was carried out for 60 days. Results: In this study, protein supplementation had a significant (p<0.05 effect on fecal egg counts even after 15 days; hemoglobin (Hb (g/dl after 45 days; total leukocyte count (103/mm3 and total erythrocyte count (106/mm3 after 30 days; packed cell volume (%, lymphocyte (%, and eosinophil (% after 15 days of supplementation, whereas monocyte (% and neutrophil (% values were not significantly influenced by protein supplementation effect during the entire experiment. The values of mean corpuscular volume (fl were affected significantly (p<0.05, p<0.01 due to protein supplementation after 30 days, mean corpuscular Hb (MCH (pg after 45 days, but MCH concentration (g/dl was not significantly different among the experimental groups during the entire experiment. Conclusion: The dietary supplementation with different levels of protein significantly improved the hematological profiles and inhibited the nematodosis infection in the experimental goat kids.

  9. Body mass index and the rheumatoid arthritis swollen joint count: an observational study

    Science.gov (United States)

    Caplan, Liron; Davis, Lisa A.; Bright, Christina M.; Kerr, Gail S.; Lazaro, Deana M.; Khan, Nasim A.; Richards, J. Steuart; Johnson, Dannette S.; Cannon, Grant W.; Reimold, Andreas M.; Mikuls, Ted R.

    2012-01-01

    Objective Obesity is a prevalent condition and a serious health concern. The relationship between obesity and RA disease activity and severity has not been adequately examined, and there are concerns that periarticular adipose tissue may reduce the utility of the joint examination. Methods We used a cross-sectional study to compare the performance of swollen joint count (SJC) in subjects with rheumatoid arthritis (RA) across body mass index (BMI) strata. Specifically, regression techniques tested for associations of SJC and seven RA disease activity/severity measures (including high sensitivity c-reactive protein, radiographic changes, and multi-dimensional health assessment questionnaire scores) within BMI quartiles. We also evaluated the association of BMI with radiographic evidence of RA in multivariate analyses and the association of BMI with SJC. Clinical and laboratory data from 980 Veterans Affairs Rheumatoid Arthritis (VARA) registry participants were analyzed using linear and logistic regression. Results Associations were evident between SJC and six of the seven examined RA disease activity/severity measures. SJC predicts RA disease activity/severity at least as well in more obese subjects as in subjects with lower BMIs, and there was a trend towards better performance in higher BMI individuals. Subjects with higher BMIs were marginally less likely to be characterized by radiographic changes (O.R. 0.98, p=0.051). We found no association between BMI and SJC. Conclusions BMI does not obscure the relationship of SJC and objective disease activity measures. There is a borderline association of higher BMI and likelihood of radiographic changes characteristic of RA after controlling for clinical characteristics. PMID:22623288

  10. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  11. Indication of total body irradiation in adult allogeneic bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Kasai, Masaharu (Sapporo Hokuyu Hospital (Japan). Artificial Organ and Transplantation Hospital)

    1992-10-01

    Indication of total body irradiation (TBI) in adult allogeneic bone marrow transplantation was discussed in comparison with non-TBI method of busulfan and cyclophosphamide (BU+CY). Each method has unique advantages and disadvantages. Concerning adverse effects of interstitial pneumonia, liver dysfunction and so on, there are no significant differences in both methods. TBI method should be preferably indicated for lymphatic leukemias and leukemias involving central nervous systems. It is important to clarify what kinds of combination regimen depending on the type and the stage of disease are most suitable for the longer survival of patients with leukemia or aplastic anemia by multicentric randomized study. (author).

  12. Thermodynamics of the living organisms. Allometric relationship between the total metabolic energy, chemical energy and body temperature in mammals

    Science.gov (United States)

    Atanasov, Atanas Todorov

    2017-11-01

    The study present relationship between the total metabolic energy (ETME(c), J) derived as a function of body chemical energy (Gchem, J) and absolute temperature (Tb, K) in mammals: ETME(c) =Gchem (Tb/Tn). In formula the temperature Tn =2.73K appears normalization temperature. The calculated total metabolic energy ETME(c) differs negligible from the total metabolic energy ETME(J), received as a product between the basal metabolic rate (Pm, J/s) and the lifespan (Tls, s) of mammals: ETME = Pm×Tls. The physical nature and biological mean of the normalization temperature (Tn, K) is unclear. It is made the hypothesis that the kTn energy (where k= 1.3806×10-23 J/K -Boltzmann constant) presents energy of excitation states (modes) in biomolecules and body structures that could be in equilibrium with chemical energy accumulated in body. This means that the accumulated chemical energy allows trough all body molecules and structures to propagate excitations states with kTn energy with wavelength in the rage of width of biological membranes. The accumulated in biomolecules chemical energy maintains spread of the excited states through biomolecules without loss of energy.

  13. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  14. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial.

    Science.gov (United States)

    Sierink, Joanne C; Treskes, Kaij; Edwards, Michael J R; Beuker, Benn J A; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G W; Luitse, Jan S K; Beenen, Ludo F M; Hollmann, Markus W; Goslings, J Carel

    2016-08-13

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in patients with trauma. We undertook an international, multicentre, randomised controlled trial at four hospitals in the Netherlands and one in Switzerland. Patients aged 18 years or older with trauma with compromised vital parameters, clinical suspicion of life-threatening injuries, or severe injury were randomly assigned (1:1) by ALEA randomisation to immediate total-body CT scanning or to a standard work-up with conventional imaging supplemented with selective CT scanning. Neither doctors nor patients were masked to treatment allocation. The primary endpoint was in-hospital mortality, analysed in the intention-to-treat population and in subgroups of patients with polytrauma and those with traumatic brain injury. The χ(2) test was used to assess differences in mortality. This trial is registered with ClinicalTrials.gov, number NCT01523626. Between April 22, 2011, and Jan 1, 2014, 5475 patients were assessed for eligibility, 1403 of whom were randomly assigned: 702 to immediate total-body CT scanning and 701 to the standard work-up. 541 patients in the immediate total-body CT scanning group and 542 in the standard work-up group were included in the primary analysis. In-hospital mortality did not differ between groups (total-body CT 86 [16%] of 541 vs standard work-up 85 [16%] of 542; p=0.92). In-hospital mortality also did not differ between groups in subgroup analyses in patients with polytrauma (total-body CT 81 [22%] of 362 vs standard work-up 82 [25%] of 331; p=0.46) and traumatic brain injury (68 [38%] of 178 vs 66 [44%] of 151; p=0.31). Three serious adverse events were reported in patients in the total-body CT group (1%), one in the standard work-up group (<1%), and

  15. Correlation between discharged worms and fecal egg counts in human clonorchiasis.

    Directory of Open Access Journals (Sweden)

    Jae-Hwan Kim

    2011-10-01

    Full Text Available BACKGROUND: Stool examination by counting eggs per gram of feces (EPGs is the best method to estimate worm burden of Clonorchis sinensis in infected humans. The present study investigated a correlation between EPGs and worm burden in human clonorchiasis. METHODS AND FINDINGS: A total of 60 residents, 50 egg-positive and 10 egg-negative, in Sancheong-gun, Korea, participated in this worm collection trial in 2006-2009. They were diagnosed by egg positivity in feces using the Kato-Katz method. After administration of praziquantel, they were purged with cathartics on the next day, and then discharged adult worms were collected from their feces. Their EPGs ranged from 0 to 65,544. Adult worms of C. sinensis were collected from 17 egg-positive cases, and the number of worms ranged from 1 to 114 in each individual. A positive correlation between EPGs and numbers of worms was demonstrated (r = 0.681, P<0.001. Worm recovery rates were 9.7% in cases of EPGs 1-1,000 and 73.7% in those of EPGs over 1,000. No worms were detected from egg-negative subjects. Maximum egg count per worm per day was roughly estimated 3,770 in a subject with EPGs 2,664 and 106 collected worms. CONCLUSIONS: The numbers of the worms are significantly correlated with the egg counts in human clonorchiasis. It is estimated that at least 110 worms are infected in a human body with EPGs around 3,000, and egg productivity of a worm per day is around 4,000.

  16. Recuento de bacterias totales en leche cruda de tambos que caracterizan la zona noroeste de Santa Fe y sur de Santiago del Estero Total bacterial count in raw milk of dairy farms that characterize the northwest zone of Santa Fe and south of Santiago del Estero

    Directory of Open Access Journals (Sweden)

    G.R. Revelli

    2004-09-01

    Full Text Available Un total de 6.998 muestras de leche cruda de pool de tanque, correspondientes a 55 establecimientos lecheros asociados a la Cooperativa Tambera Nueva Alpina Ltda., fueron recolectadas entre los años 1993 y 2002. Se realizó el Recuento de Microorganismos Aerobios Mesófilos Totales, obteniéndose como resultado un valor medio de 1,2 x 105± 2,4 x 105UFC/ml que caracteriza la zona. El año de finalización de la experiencia, se observó un 97% de los tambos evaluados con promedios £ 1,0 x 105UFC/ml. Solamente un 3% sobrepasa este límite, no encontrándose establecimientos con niveles superiores a 1,5 x 105UFC/ml. Al relacionar este indicador con parámetros composicionales, las correlaciones más significativas resultaron para: Recuento de Bacterias Totales vs Acidez (r = 0,292; P A total of 6.998 raw milk samples of bulk tank, belonging to 55 dairy farms associated to the Cooperativa Tambera Nueva Alpina Ltda., were collected between the years 1993 and 2002. The Total Mesophilic Aerobic Microorganisms Count was analyzed, obtaining a medium value of 1.2 x 105± 2.4 x 105CFU/ml that characterizes the zone. The final year of experience, observed a 97% of dairy farms evaluated with averages £ 1,0 x 105CFU/ml. Only a 3% it surpasses this limit, not being found establishments with levels over 1.5 x 105CFU/ml. Relating this indicators with compositionals parameters, the most significant correlation resulted for: Total Bacterial Count vs Acidity (r = 0.292; P < 0.001 and Total Bacterial Count vs Freezing Point (r = 0.157; P < 0.001. The microbiological quality in raw milk of dairy farms belonging to the northwest zone of Santa Fe and south of Santiago del Estero showed a significant improvement during this time.

  17. Examination of some chelating agents to decorporate fixed body-burdens of cadmium

    International Nuclear Information System (INIS)

    Jones, C.W.; Lloyd, R.D.; Mays, C.W.

    1979-01-01

    Male and female C57BL/Do mice, five to six months old, were injected intraperitoneally with 2.0 mg/kg cadmium citrate labeled with about 2.0 μCi 109 Cd per mouse. Three days after cadmium injection, male mice were injected subcutaneously with 2,3 dimercaptopropanesulfonate (DMPS), and female mice were injected subcutaneously with calcium disodium ethylenediaminetetra-acetate (CaEDTA), salicylic acid (SA), or 2,3 dimercaptopropanesulfonate, alone, or in combination. A total of four treatment injections were administered to each group of mice. Cadmium total-body retention was measured by in vivo counting using NaI(T1) spectrometry. Male mice given DMPS, and groups of females given EDTA, SA, EDTA + DMPS, EDTA + SA, or EDTA + DMPS + SA had total-body retentions of cadmium no different from saline controls (P > 0.05). Measurement of cadmium content in kidneys, livers, gonads, and femora excised from test animals also showed no difference from corresponding organs in control animals

  18. Fitting a distribution to miccrobial counts: making sense of zeros

    DEFF Research Database (Denmark)

    Ribeiro Duarte, Ana Sofia; Stockmarr, Anders; Nauta, Maarten

    and standard deviation) and the prevalence of contaminated food units (one minus the proportion of “true zeros”) from a set of microbial counts. By running the model with in silico generated concentration and count data, we could evaluate the performance of this method in terms of estimation of the three......Non-detects or left-censored results are inherent to the traditional methods of microbial enumeration in foods. Typically, a low concentration of microorganisms in a food unit goes undetected in plate counts or most probable number (MPN) counts, and produces “artificial zeros”. However......, these “artificial zeros” are only a share of the total number of zero counts resulting from a sample, as their number adds up to the number of “true zeros” resulting from uncontaminated units. In the process of fitting a probability distribution to microbial counts, “artificial” and “true” zeros are usually...

  19. The relationships among total body fat, bone mineral content and bone marrow adipose tissue in early-pubertal girls.

    Science.gov (United States)

    L Newton, Anna; J Hanks, Lynae; Davis, Michelle; Casazza, Krista

    2013-01-01

    Investigation of the physiologic relevance of bone marrow adipose tissue (BMAT) during growth may promote understanding of the bone-fat axis and confluence with metabolic factors. The objective of this pilot investigation was two-fold: (1) to evaluate the relationships among total body fat, bone mineral content (BMC) and femoral BMAT during childhood and underlying metabolic determinants and (2) to determine if the relationships differ by race. Participants included white and non-Hispanic black girls (n=59) ages 4-10 years. Femoral BMAT volume was measured by magnetic resonance imaging, BMC and body fat by dual-energy X-ray absorptiometry. Metabolic parameters were assessed in the fasted state. Total fat and BMC were positively associated with BMAT; however, simultaneous inclusion of BMC and body fat in the statistical model attenuated the association between BMC and BMAT. Differences in BMAT volume were observed, non-Hispanic black girls exhibiting marginally greater BMAT at age eight (P=0.05) and white girls exhibiting greater BMAT at age ten (PBMAT and leptin (P=0.02) and adiponectin (P=0.002) in white girls while BMAT and insulin were inversely related in non-Hispanic black girls (P=0.008). Our findings revealed a positive relationship between BMAT, body fat and BMC, although body fat, respective to leptin, contributed partly to the relationship between BMAT and BMC. Despite large differences in total fat between non-Hispanic black and white, the relationship between BMAT and BMC was similar to white girls. However, this relationship appeared to be impacted through different mechanisms according to race.

  20. Limit of sensitivity of low-background counting equipment

    International Nuclear Information System (INIS)

    Homann, S.G.

    1991-01-01

    The Hazards Control Department's Radiological Measurements Laboratory (RML) analyzes many types of sample media in support of the Laboratory's health and safety program. The Department has determined that the equation for the minimum limit of sensitivity, MDC(α,β) = 2.71 + 3.29 (r b t s ) 1/2 is also adequate for RML counting systems with very-low-background levels. This paper reviews the normal distribution case and address the special case of determining the limit of sensitivity of a counting system when the background count rate is well known and small. In the latter case, we must use an exact test procedure based on the binomial distribution. However, the error in using the normal distribution for calculating a detection system's limit of sensitivity is not significant even as the total observed number of counts approaches or equals zero. 2 refs., 4 figs

  1. A Trial-and-Error Method with Autonomous Vehicle-to-Infrastructure Traffic Counts for Cordon-Based Congestion Pricing

    Directory of Open Access Journals (Sweden)

    Zhiyuan Liu

    2017-01-01

    Full Text Available This study proposes a practical trial-and-error method to solve the optimal toll design problem of cordon-based pricing, where only the traffic counts autonomously collected on the entry links of the pricing cordon are needed. With the fast development and adoption of vehicle-to-infrastructure (V2I facilities, it is very convenient to autonomously collect these data. Two practical properties of the cordon-based pricing are further considered in this article: the toll charge on each entry of one pricing cordon is identical; the total inbound flow to one cordon should be restricted in order to maintain the traffic conditions within the cordon area. Then, the stochastic user equilibrium (SUE with asymmetric link travel time functions is used to assess each feasible toll pattern. Based on a variational inequality (VI model for the optimal toll pattern, this study proposes a theoretically convergent trial-and-error method for the addressed problem, where only traffic counts data are needed. Finally, the proposed method is verified based on a numerical network example.

  2. Near infrared system coupled chemometric algorithms for enumeration of total fungi count in cocoa beans neat solution.

    Science.gov (United States)

    Kutsanedzie, Felix Y H; Chen, Quansheng; Hassan, Md Mehedi; Yang, Mingxiu; Sun, Hao; Rahman, Md Hafizur

    2018-02-01

    Total fungi count (TFC) is a quality indicator of cocoa beans when unmonitored leads to quality and safety problems. Fourier transform near infrared spectroscopy (FT-NIRS) combined with chemometric algorithms like partial least square (PLS); synergy interval-PLS (Si-PLS); synergy interval-genetic algorithm-PLS (Si-GAPLS); Ant colony optimization - PLS (ACO-PLS) and competitive-adaptive reweighted sampling-PLS (CARS-PLS) was employed to predict TFC in cocoa beans neat solution. Model results were evaluated using the correlation coefficients of the prediction (Rp) and calibration (Rc); root mean square error of prediction (RMSEP), and the ratio of sample standard deviation to RMSEP (RPD). The developed models performance yielded 0.951≤Rp≤0.975; and 3.15≤RPD≤4.32. The models' prediction stability improved in the order of PLS

  3. TOTAL HEMOCYTE COUNT AND HEMOLYMPH GLUCOSE CONCENRATION RESPONSE OF SPINY LOBSTER Panulirus homarus ON RATIO OF SHELTER

    Directory of Open Access Journals (Sweden)

    Suhaiba Djai

    2017-11-01

    Full Text Available This research was conducted to assess the physiological response of the lobster Panulirus homarus for the ratio of the shelters. The method used completely randomized design with two replicates of each treatments with shelter ratio (A 1 : 5, (B 3 : 5, (C 4 : 5, (D 5 : 5. Weight average for 184 lobsters with the stocking density of 23 lobsters for each treatment was 32.64 ± 0.58 g. The experiment was conducted for 60 days. The lobster was fed with trash fish and acclimatized for 7 days before the experiment. Observations on the physiologycal of every 10 days. The physiological responses that observed were total hemocyte count (THC and hemolymph glucose concentration. The results showed that 4:5 was the best lobster shelter ratio because it could reduce stress levels. This is indicated by the stable values of THC and hemolymph glucose level during the experiment and supported by the growth of 57.28 ± 0.15 g and survival rate of 91.31 ± 2.60%. Keywords: lobster, Panulirus homarus, ratio, shelter, THC, glucose

  4. Treatment verification and in vivo dosimetry for total body irradiation using thermoluminescent and semiconductor detectors

    International Nuclear Information System (INIS)

    Oliveira, F.F.; Amaral, L.L.; Costa, A.M.; Netto, T.G.

    2014-01-01

    The objective of this work is the characterization of thermoluminescent and semiconductor detectors and their applications in treatment verification and in vivo dosimetry for total body irradiation (TBI) technique. Dose measurements of TBI treatment simulation performed with thermoluminescent detectors inserted in the holes of a “Rando anthropomorphic phantom” showed agreement with the prescribed dose. For regions of the upper and lower chest where thermoluminescent detectors received higher doses it was recommended the use of compensating dose in clinic. The results of in vivo entrance dose measurements for three patients are presented. The maximum percentual deviation between the measurements and the prescribed dose was 3.6%, which is consistent with the action level recommended by the International Commission on Radiation Units and Measurements (ICRU), i.e., ±5%. The present work to test the applicability of a thermoluminescent dosimetric system and of a semiconductor dosimetric system for performing treatment verification and in vivo dose measurements in TBI techniques demonstrated the value of these methods and the applicability as a part of a quality assurance program in TBI treatments. - Highlights: • Characterization of a semiconductor dosimetric system. • Characterization of a thermoluminescent dosimetric system. • Application of the TLDs for treatment verification in total body irradiation treatments. • Application of semiconductor detectors for in vivo dosimetry in total body irradiation treatments. • Implementation of in vivo dosimetry as a part of a quality assurance program in radiotherapy

  5. INFLUENCE OF SOMATIC CELL COUNT IN THE COMPOSITION OF GIROLANDO COW’S MILK IN TROPICAL ZONE

    Directory of Open Access Journals (Sweden)

    Vanessa Nunes Silva

    2016-08-01

    Full Text Available Bovine mastitis has been identified as the main disease affecting dairy cattle worldwide. Somatic Cell Count (SCC in milk is one of the most important indicators to evaluate the udder health of cows due to the high direct correlation with the mammary gland’s degree of infection. This study aimed to evaluate the different ranges of somatic cell count (SCC on the composition of bovine milk as well as finding a correlation between somatic cell count and body condition score on milk production and composition of this species. The experiment was conducted on a commercial farm located in São José de Mipibu, Rio Grande do Norte, Brazil. The same cows were milked mechanically, obtaining a milk production record for the period of December 2011 to May 2012. For this, 24 Girolando breed cows (3/4 and 7/8 were used, being 50% primiparous and 50% multiparous with average production 7.51 ± 2.58 kg day-1 and 10.98 ± 2.49 kg day-1, respectively. The cows were milked mechanically, obtaining a record of milk production over a period of five months, and milk samples were collected and sent for laboratory analysis. The levels of milk composition were evaluated. Lactose, non-fat solids and milk urea nitrogen were influenced by different intervals of somatic cell count of milk. In milk samples from primiparous and multiparous cows, positive correlations between somatic cell count and some components were found. As for body condition score, significant correlations were also found for milk production and composition. It was concluded the different levels of somatic cell count influenced the percentage of lactose, non-fat solids and milk urea nitrogen. Somatic cell count and body condition score also showed significant correlations with milk production and composition.

  6. Fetal liver transplantation in 2 patients with acute leukaemia after total body irradiation

    International Nuclear Information System (INIS)

    Lucarelli, G.; Izzi, T.; Porcellini, A.; Delfini, C.; Galimberti, M.; Moretti, L.; Polchi, P.; Agostinelli, F.; Andreani, M.; Manna, M.; Dallapiccola, B.

    1982-01-01

    2 patients with acute leukaemia in relapse were transplanted with fetal liver cells following a conditioning regimen of cyclophosphamide (120 mg/kg) and total body irradiation (1000 r). Each patient achieved a remission with haematopoietic recovery that was rapid in one case and delayed in the other. In one case there was evidence of chimerism as demonstrated by the presence of the XYY karyotype of the donor fetus in 20 % of marrow metaphases, by the presence of double Y bodies in the peripheral blood, by the appearance of new HLA-antigens, and by red cell isoenzyme phenotypes of donor origin. In the second case there was prompt haemotopoietic recovery and the appearance of red cell isoenzyme phenotypes of donor origin. Survival was 153 and 30 d, respectively, and both patients died of interstitial pneumonia without evidence of graft versus host disease. (author)

  7. Cross-sex hormone therapy in transgender persons affects total body weight, body fat and lean body mass: a meta-analysis.

    Science.gov (United States)

    Klaver, M; Dekker, M J H J; de Mutsert, R; Twisk, J W R; den Heijer, M

    2017-06-01

    Weight gain and body fat increase the risk of cardiometabolic disease. Cross-sex hormone therapy in transgender persons leads to changes in body weight and body composition, but it is unclear to what extent. We performed a meta-analysis to investigate the changes in body weight, body fat and lean body mass during cross-sex hormone therapy in transgender persons. We searched the PubMed database for eligible studies until November 2015. Ten studies reporting changes in body weight, body fat or lean mass in hormone naive transgender persons were included, examining 171 male-to-female and 354 female-to-male transgender people. Pooled effect estimates in the male-to-female group were +1.8 kg (95% CI: 0.2;3.4) for body weight, +3.0 kg (2.0;3.9) for body fat and -2.4 kg (-2.8; -2.1) for lean body mass. In the female-to-male group, body weight changed with +1.7 kg (0.7;2.7), body fat with -2.6 kg (-3.9; -1.4) and lean body mass with +3.9 kg (3.2;4.5). Cross-sex hormone therapy increases body weight in both sexes. In the male-to-female group, a gain in body fat and a decline in lean body mass are observed, while the opposite effects are seen in the female-to-male group. Possibly, these changes increase the risk of cardiometabolic disease in the male-to-female group. © 2016 Blackwell Verlag GmbH.

  8. Environmental Control Plan for the Industrial Hygiene Field Services Facility

    International Nuclear Information System (INIS)

    Donnelly, J.W.

    2000-01-01

    This environmental control plan is for the Hanford Site's Industrial Hygiene Field Services Facility, located in the 100-N Area. This facility is used for the maintenance and storage of respirators, respiratory equipment and testing, calibration and testing of industrial hygiene equipment, and asbestos fiber counting

  9. Radiobiological considerations in the treatment of neuroblastoma by total body irradiation

    International Nuclear Information System (INIS)

    Wheldon, T.E.; O'Donoghue, J.; Gregor, A.; Livingstone, A.; Wilson, L.; West of Scotland Health Boards, Glasgow

    1986-01-01

    Neuroblastoma is a radiosensitive neoplasm for which total body irradiation (TBI) is presently under clinical consideration. Collated data on the radiobiology of human neuroblastoma cells in vitro indicates moderate cellular radiosensitivity and low capacity for accumulation of sublethal damage. Mathematical studies incorporating these parameters suggest that low dose fractionated TBI is unlikely to achieve significant levels of tumour cell kill. When high dose TBI is used in conjuction with bone marrow rescue a tumour 'log cell kill' of 4-5 should be achievable. This effect would be additional to that acheived by chemotherapy. Fractionated TBI with bone marrow rescue may be curative for some patients in clinical remission who are presently destined to relapse. (Auth.)

  10. Inability of donor total body irradiation to prolong survival of vascularized bone allografts: Experimental study in the rat

    International Nuclear Information System (INIS)

    Gonzalez del Pino, J.; Benito, M.; Randolph, M.A.; Weiland, A.J.

    1990-01-01

    At the present time, the toxic side effects of recipient immunosuppression cannot be justified for human non-vital organ transplantation. Total body irradiation has proven effective in ablating various bone-marrow-derived and endothelial immunocompetent cellular populations, which are responsible for immune rejection against donor tissues. Irradiation at a dose of 10 Gy was given to donor rats six days prior to heterotopic transplantation of vascularized bone allografts to host animals. Another group of recipient rats also received a short-term (sixth to fourteenth day after grafting), low dose of cyclosporine. Total body irradiation was able merely to delay rejection of grafts across a strong histocompatibility barrier for one to two weeks, when compared to nonirradiated allografts. The combination of donor irradiation plus cyclosporine did not delay the immune response, and the rejection score was similar to that observed for control allografts. Consequently, allograft viability was quickly impaired, leading to irreversible bone damage. This study suggest that 10 Gy of donor total body irradiation delivered six days prior to grafting cannot circumvent the immune rejection in a vascularized allograft of bone across a strong histocompatibility barrier

  11. The effect of whole body or total-head x irradiation of the metallophilic cells in the mice spleen

    International Nuclear Information System (INIS)

    Sasaki, Osamu; Matsueda, Yasutoshi; Mizuguchi, Hiroshi; Moriguchi, Kenzo; Ogata, Kunitoshi; Sugie, Tsuneto

    1984-01-01

    The purpose of this paper is to clarify morphological changes of the reticuloendothelial cells in the spleen following X-irradiation by Katsura's silver impregnation method. The animals used in this experiment were ddN female mice weighing 20 to 25g. The mice were given X-irradiation to the total-head (1,500R) or whole body (300R). The metallophilic cells in the spleen of control mice were of the small foamy type in the follicle, the large stellate type in the marginal metallophils, the small branching type in the marginal zone and the small foamy or round type in the red pulp, respectively. The metallophilic cells decreased immediately after whole body irradiation and the number of cells returned to normal in from 10 to 14 days. On the other hand, the number of the metallophilic cells in the follicle and the perifollicular region increased immediately after total-head X-irradiation. This state continued for several days. In the marginal zone and red pulp, the number of amoebian type cells appeared from 24 hours after irradiation and the number of cells in total-head irradiation group were more clearly distinguishable than in the whole body irradiated group. (author)

  12. A Next Generation Digital Counting System For Low-Level Tritium Studies (Project Report)

    International Nuclear Information System (INIS)

    Bowman, P.

    2016-01-01

    Since the early seventies, SRNL has pioneered low-level tritium analysis using various nuclear counting technologies and techniques. Since 1999, SRNL has successfully performed routine low-level tritium analyses with counting systems based on digital signal processor (DSP) modules developed in the late 1990s. Each of these counting systems are complex, unique to SRNL, and fully dedicated to performing routine tritium analyses of low-level environmental samples. It is time to modernize these systems due to a variety of issues including (1) age, (2) lack of direct replacement electronics modules and (3) advances in digital signal processing and computer technology. There has been considerable development in many areas associated with the enterprise of performing low-level tritium analyses. The objective of this LDRD project was to design, build, and demonstrate a Next Generation Tritium Counting System (NGTCS), while not disrupting the routine low-level tritium analyses underway in the facility on the legacy counting systems. The work involved (1) developing a test bed for building and testing new counting system hardware that does not interfere with our routine analyses, (2) testing a new counting system based on a modern state of the art DSP module, and (3) evolving the low-level tritium counter design to reflect the state of the science.

  13. Estimation of the dose distribution within, and total dose to, the body of an acutely overexposed person

    International Nuclear Information System (INIS)

    Beer, G.P. de; Feather, J.I.; Oude, A. de; Language, A.E.

    1981-01-01

    In a case of accidental overexposure of a person, it is important to obtain a reliable value of the whole body dose as well as of the dose distribution within the body. Any follow-up treatment based only on the clinical effects as and when they appear, may result in insufficient or even erroneous therapy. In this respect knowledge of total dose and its distribution within the body may be a valuable aid in deciding on the follow-up treatment, taking into account the latent nature of the clinical effects. The calculated whole body dose and its distribution within the body of a person overexposed to a 192 Ir radiography source, are compared to experimentally determined values. In both cases the calculated values prove to be of sufficient accuracy to serve as an aid in decisions on the follow-up treatment. (author)

  14. A Monte Carlo modeling alternative for the API Gamma Ray Calibration Facility.

    Science.gov (United States)

    Galford, J E

    2017-04-01

    The gamma ray pit at the API Calibration Facility, located on the University of Houston campus, defines the API unit for natural gamma ray logs used throughout the petroleum logging industry. Future use of the facility is uncertain. An alternative method is proposed to preserve the gamma ray API unit definition as an industry standard by using Monte Carlo modeling to obtain accurate counting rate-to-API unit conversion factors for gross-counting and spectral gamma ray tool designs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Evaluating remotely sensed plant count accuracy with differing unmanned aircraft system altitudes, physical canopy separations, and ground covers

    Science.gov (United States)

    Leiva, Josue Nahun; Robbins, James; Saraswat, Dharmendra; She, Ying; Ehsani, Reza

    2017-07-01

    This study evaluated the effect of flight altitude and canopy separation of container-grown Fire Chief™ arborvitae (Thuja occidentalis L.) on counting accuracy. Images were taken at 6, 12, and 22 m above the ground using unmanned aircraft systems. Plants were spaced to achieve three canopy separation treatments: 5 cm between canopy edges, canopy edges touching, and 5 cm of canopy edge overlap. Plants were placed on two different ground covers: black fabric and gravel. A counting algorithm was trained using Feature Analyst®. Total counting error, false positives, and unidentified plants were reported for images analyzed. In general, total counting error was smaller when plants were fully separated. The effect of ground cover on counting accuracy varied with the counting algorithm. Total counting error for plants placed on gravel (-8) was larger than for those on a black fabric (-2), however, false positive counts were similar for black fabric (6) and gravel (6). Nevertheless, output images of plants placed on gravel did not show a negative effect due to the ground cover but was impacted by differences in image spatial resolution.

  16. Total and Segmental Body Composition Examination in Collegiate Football Players Using Multifrequency Bioelectrical Impedance Analysis and Dual X-ray Absorptiometry.

    Science.gov (United States)

    Raymond, Christiana J; Dengel, Donald R; Bosch, Tyler A

    2018-03-01

    Raymond, CJ, Dengel, DR, and Bosch, TA. Total and segmental body composition examination in collegiate football players using multifrequency bioelectrical impedance analysis and dual X-ray absorptiometry. J Strength Cond Res 32(3): 772-782, 2018-The current study examined the influence of player position on the agreement between multifrequency bioelectrical impedance analysis (MfBIA) and dual X-ray absorptiometry (DXA) when assessing total and segmental percent body fat (BF%), fat mass (FM), and fat-free mass (FFM) in National Collegiate Athletic Association Division I collegiate football athletes. Forty-four male collegiate athletes (age = 19 ± 1 year; height = 1.9 ± 1.0 m; and body mass = 106.4 ± 18.8 kg) participated. Player positions included: offensive linemen (OL; n = 7), tight ends (TE; n = 4), wide receivers (WR; n = 9), defensive linemen (DL; n = 6), defensive backs (DB; n = 8), linebackers (LB; n = 6), and running backs (RB; n = 4). Total and segmental body composition measured using MfBIA were compared with values obtained using DXA. Compared with DXA, MfBIA underestimated BF% (3.0 ± 3.8%), total FM (2.5 ± 4.3 kg), arm FM (0.4 ± 0.8 kg), arm FFM (1.4 ± 0.9 kg), leg FM (2.8 ± 2.0 kg), and leg FFM (5.4 ± 2.4 kg) (all p FFM (-2.4 ± 4.5 kg) (p FFM), ±3.83 kg (leg FM), ±4.62 kg (leg FFM), and ±8.83 kg (total FFM). No significant differences were observed between devices for trunk FM (-0.3 ± 3.0 kg; p = 0.565) and trunk FFM (0.4 ± 2.4 kg; p = 0.278), with LOAs of ±5.92 and ±4.69 kg, respectively. Player position significantly affected all between-device mean body composition measurement differences (adjusted p ≤ 0.05), with OL demonstrating the greatest effect on each variable. Therefore, MfBIA does not seem accurate in examining between-player body composition in college football players.

  17. Gross alpha/beta analyses in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wong, C.T.; Lawrence Livermore National Laboratory, CA; Soliman, V.M.; Perera, S.K.

    2005-01-01

    The standard procedure for analyzing gross alpha and gross beta in water is evaporation of the sample and radioactivity determination of the resultant solids by proportional counting. This technique lacks precision, and lacks sensitivity for samples with high total dissolved solids. Additionally, the analytical results are dependent on the choice of radionuclide calibration standard and the sample matrix. Direct analysis by liquid scintillation counting has the advantages of high counting efficiencies and minimal sample preparation time. However, due to the small sample aliquants used for analysis, long count times are necessary to reach required detection limits. The procedure proposed consists of evaporating a sample aliquant to dryness, dissolving the resultant solids in a small volume of dilute acid, followed by liquid scintillation counting to determine radioactivity. This procedure can handle sample aliquants containing up to 500 mg of dissolved solids. Various acids, scintillation cocktail mixtures, instrument discriminator settings, and regions of interest (ROI) were evaluated to determine optimum counting conditions. Precision is improved and matrix effects are reduced as compared to proportional counting. Tests indicate that this is a viable alternative to proportional counting for gross alpha and gross beta analyses of water samples. (author)

  18. A Common Allele in FGF21 Associated with Sugar Intake Is Associated with Body Shape, Lower Total Body-Fat Percentage, and Higher Blood Pressure

    Directory of Open Access Journals (Sweden)

    Timothy M. Frayling

    2018-04-01

    Full Text Available Summary: Fibroblast growth factor 21 (FGF21 is a hormone that has insulin-sensitizing properties. Some trials of FGF21 analogs show weight loss and lipid-lowering effects. Recent studies have shown that a common allele in the FGF21 gene alters the balance of macronutrients consumed, but there was little evidence of an effect on metabolic traits. We studied a common FGF21 allele (A:rs838133 in 451,099 people from the UK Biobank study, aiming to use the human allele to inform potential adverse and beneficial effects of targeting FGF21. We replicated the association between the A allele and higher percentage carbohydrate intake. We then showed that this allele is more strongly associated with higher blood pressure and waist-hip ratio, despite an association with lower total body-fat percentage, than it is with BMI or type 2 diabetes. These human phenotypes of variation in the FGF21 gene will inform research into FGF21’s mechanisms and therapeutic potential. : Drugs targeting the hormone FGF21 may have beneficial health effects. Variations in human DNA in the FGF21 gene provide an indication of what those effects may be. Here, we show that variation in the FGF21 gene is associated with higher blood pressure and altered body shape, despite lower total body-fat percentage. Keywords: FGF21, BMI, waist-hip ratio, blood pressure, body fat, allele, genetic variant, UK Biobank

  19. Incidence of interstitial pneumonia after hyperfractionated total body irradiation before autologous bone marrow/stem cell transplantation

    International Nuclear Information System (INIS)

    Lohr, F.; Schraube, P.; Wenz, F.; Flentje, M.; Kalle, K. von; Haas, R.; Hunstein, W.; Wannenmacher, M.

    1995-01-01

    Purpose/Objectives Interstitial pneumonia (IP) is a severe complication after allogenic bone marrow transplantation (BMT) with incidence rates between 10 % and 40 % in different series. It is a polyetiologic disease that occurs depending on age, graft vs. host disease (GvHD), CMV-status, total body irradiation (TBI) and immunosuppressive therapy after BMT. The effects of fractionation and dose rate are not entirely clear. This study evaluates the incidence of lethal IP after hyperfractionated TBI for autologous BMT or stem cell transplantation. Materials and Methods Between 1982 and 1992, 182 patients (60 % male, 40 % female) were treated with hyperfractionated total body irradiation (TBI) before autologous bone marrow transplantation. Main indications were leukemias and lymphomas (53 % AML, 21 % ALL, 22 % NHL, 4 % others) Median age was 30 ys (15 - 55 ys). A total dose of 14.4 Gy was applied using lung blocks (12 fractions of 1.2 Gy in 4 days, dose rate 7-18 cGy/min, lung dose 9 - 9.5 Gy). TBI was followed by cyclophosphamide (200 mg/kg). 72 % were treated with bone marrow transplantation, 28 % were treated with stem cell transplantation. Interstitial pneumonia was diagnosed clinically, radiologically and by autopsy. Results 4 patients died most likely of interstitial pneumonia. For another 12 patients interstitial pneumonia was not the most likely cause of death but could not be excluded. Thus, the incidence of lethal IP was at least 2.2 % but certainly below 8.8 %. Conclusion Lethal interstitial pneumonia is a rare complication after total body irradiation before autologous bone marrow transplantation in this large, homogeously treated series. In the autologous setting, total doses of 14.4 Gy can be applied with a low risk for developing interstitial pneumonia if hyperfractionation and lung blocks are used. This falls in line with data from series with identical twins or t-cell depleted marrow and smaller, less homogeneous autologous transplant studies. Thus

  20. Murine partial-body radiation exposure model for biodosimetry studies - Preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Blakely, William F., E-mail: blakely@afrri.usuhs.mil [Uniformed Services University, Armed Forces Radiobiology Research Institute, Scientific Research Department, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States); Sandgren, David J., E-mail: Sandgren@afrri.usuhs.mil [Uniformed Services University, Armed Forces Radiobiology Research Institute, Scientific Research Department, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States); Nagy, Vitaly, E-mail: nagy@afrri.usuhs.mil [Uniformed Services University, Armed Forces Radiobiology Research Institute, Scientific Research Department, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States); Kim, Sung-Yop, E-mail: kimy@afrri.usuhs.mil [Uniformed Services University, Armed Forces Radiobiology Research Institute, Scientific Research Department, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States); Ossetrova, Natalia I., E-mail: ossetrova@afrri.usuhs.mil [Uniformed Services University, Armed Forces Radiobiology Research Institute, Scientific Research Department, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)

    2011-09-15

    The objective of the present study was to establish a murine partial-body radiation exposure model for studies supporting the identification and validation of novel biological dosimetry diagnostic assays. A lead shielding - Plexiglas irradiation apparatus with cutouts to permit irradiation of single-mouse-holder constrained CD2F1 male mice to total-body (3/3), mid- and lower-body (2/3), mid-body only (1/3), and 100% lead shielding sham-treated (0 Gy) controls (0/3) with a 250-kVp X-ray source (dose: 6 Gy, dose rate: 0.50 Gy min{sup -1}) was used. Doses and dose uniformity were measured using alanine - electron paramagnetic resonance (EPR) and ionization chambers. Dosimetry mapping results showed {approx}2 and {approx}12% non-uniformity in the radiation fields for the two smaller (1/3, 2/3) and one larger (3/3) fields, respectively. Hematology results showed no marked differences in neutrophil and platelet counts 1 and 2 days (d) after irradiation. The lymphocyte counts, as expected, demonstrate a progressive decline below baseline levels 1 and 2 d after irradiation with increasing fraction of the body exposed, while the neutrophil to lymphocyte ratios show the inverse effect, with a progressive increase with the fraction of body exposed. The bone marrow biomarker, Flt3 ligand, demonstrated a progressive increase in values with increasing fraction of the body exposed; the 2 d response was enhanced compared to 1 d. The radioresponse 1 d after irradiation for the acute phase reactant protein biomarker, serum amyloid A (SAA) that is synthesized by the liver, was significantly influenced depending on whether the mouse head was in the radiation field. Use of multiple biomarkers based on hematology and proteomic targets provide an enhancement in early-phase partial-body radiation exposure assessment.

  1. Effect of dietary protein quality on the resistance of rats to total body radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bounous, G.; Pageau, R.

    1983-02-01

    Young rats have been fed four defined-formula diets before and after ..gamma..-irradiation (700 rd (7.0 Gy), 75 rd/min (750 mGy), 80 cm from the source, total body). Animals eating a diet containing lactalbumin hydrolyzate (20 g/100 g diet) exhibited less anorexia and weight loss following ..gamma..-rays than a corresponding group eating casein hydrolyzate (20 g/100 g diet).

  2. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  3. Relationship of milking rate to somatic cell count.

    Science.gov (United States)

    Brown, C A; Rischette, S J; Schultz, L H

    1986-03-01

    Information on milking rate, monthly bucket somatic cell counts, mastitis treatment, and milk production was obtained from 284 lactations of Holstein cows separated into three lactation groups. Significant correlations between somatic cell count (linear score) and other parameters included production in lactation 1 (-.185), production in lactation 2 (-.267), and percent 2-min milk in lactation 2 (.251). Somatic cell count tended to increase with maximum milking rate in all lactations, but correlations were not statistically significant. Twenty-nine percent of cows with milking rate measurements were treated for clinical mastitis. Treated cows in each lactation group produced less milk than untreated cows. In the second and third lactation groups, treated cows had a shorter total milking time and a higher percent 2-min milk than untreated cows, but differences were not statistically significant. Overall, the data support the concept that faster milking cows tend to have higher cell counts and more mastitis treatments, particularly beyond first lactation. However, the magnitude of the relationship was small.

  4. Eosinophil count is positively correlated with coronary artery calcification

    International Nuclear Information System (INIS)

    Tanaka, Muhei; Fukui, Michiaki; Yamasaki, Masahiro; Hasegawa, Goji; Oda, Yohei; Nakamura, Naoto; Tomiyasu, Ki-ichiro; Akabame, Satoshi; Nakano, Koji

    2012-01-01

    Recent studies suggested that allergic disorders and increased eosinophil count were associated with atherosclerosis. The purpose of this study was to assess the relationship between eosinophil count and coronary artery calcification (CAC). We performed a cross-sectional study in 1363 consecutive participants with clinical suspicion of coronary heart disease (CHD). We evaluated the relationships between CAC score determined by multislice CT and peripheral eosinophil count as well as major cardiovascular risk factors, including age, body mass index, smoking status, hypertension, dyslipidemia, diabetes mellitus (DM), high-sensitivity C-reactive protein and estimated glomerular filtration rate (eGFR). Sex (P=0.0004), hypertension (P=0.0002), dyslipidemia (P=0.0004) and DM (P=0.0061) were associated with log (CAC+1), respectively. Positive correlations were found between log (CAC+1), and age (r=0.325, P<0.0001) and eosinophil count (r=0.165, P<0.0001). Negative correlations were found between log (CAC+1) and eGFR (r=-0.166, P<0.0001). Multivariate linear regression analysis demonstrated that age (β=0.314, P<0.0001), sex (β=0.124, P<0.0001), hypertension (β=0.084, P=0.0008), DM (β=0.108, P<0.0001), eGFR (β=-0.079, P=0.0021) and eosinophil count (β=0.147, P<0.0001) were independent determinants of log (CAC+1). In conclusion, eosinophil count correlated positively with CAC in participants with clinical suspicion of CHD. (author)

  5. Use of the cellular model of body composition to describe changes in body water compartments after total fasting, very low calorie diet and low calorie diet in obese men.

    Science.gov (United States)

    Siervo, M; Faber, P; Gibney, E R; Lobley, G E; Elia, M; Stubbs, R J; Johnstone, A M

    2010-05-01

    The cellular model of body composition divides the body in body cell mass (BCM), extracellular solids and extracellular fluids. This model has been infrequently applied for the evaluation of weight loss (WL) programmes. (1) To assess changes in body compartments in obese men undergoing fasting, very low calorie diet (VLCD) and low calorie diet (LCD); (2) to evaluate two cellular models for the determination of changes in BCM, fat mass (FM) and body fluids. Three groups of six, obese men participated in a total fast (F) for 6 days, a VLCD (2.5 MJ per day) for 3 weeks or an LCD (5.2 MJ per day) for 6 weeks. Body composition was measured at baseline and after small ( approximately 5%) and moderate ( approximately 10%) WL. FM was measured using a four-compartment model. Total body water (TBW) and extracellular water (ECW) were, respectively, measured by deuterium and sodium bromide dilution and intracellular water (ICW) calculated by difference. Two cellular models were used to measure BCM, FM and body fluids distribution. After about 5%WL changes in TBW were F=-3.2+/-1.2 kg (Pfasting (+1.5+/-3.1 kg, n.s.), decreased during the VLCD (-2.0+/-1.5 kg, Pfasting (-4.7+/-3.9 kg, Pfasting group and it was directly associated with changes in ICW. After a 6-day period of fasting we observed more ICW losses and less fat mobilization compared with VLCD and LCD. The cellular model of body composition is suitable for the characterization of changes in body fluids distribution during WL.

  6. An Acute Transverse Myelitis Attack after Total Body Irradiation: A Rare Case

    Directory of Open Access Journals (Sweden)

    Muzaffer Keklik

    2013-01-01

    Full Text Available Total body irradiation (TBI combined with chemotherapy is widely used as a pretreatment regimen of bone marrow transplantation (BMT in hematologic disorders. Late complications related to TBI as part of the conditioning regimen for hematopoietic stem cell transplantation have been revealed. Acute transverse myelitis (ATM is a neurological syndrome characterized by disorder of motor, sensorial, and autonomic nerves, and tracts at medulla spinalis, which is resulted from involvement of spinal cord. In this paper, we presented an ATM attack developed after TBI in a patient with acute lymphoblastic leukemia (ALL as it is a rarely seen case.

  7. Associations between access to recreational physical activity facilities and body mass index in Scottish adults

    Directory of Open Access Journals (Sweden)

    Anne Ellaway

    2016-08-01

    Full Text Available Abstract Background The aim of this country-wide study was to link individual health and behavioural data with area-level spatial data to examine whether the body mass index (BMI of adults was associated with access to recreational physical activity (PA facilities by different modes of transport (bus, car, walking, cycling and the extent to which any associations were mediated by PA participation. Methods Data on individual objectively-measured BMI, PA (number of days of (a ≥20 min of moderate-to-vigorous PA, and (b ≥15 min of sport or exercise, in previous 4 weeks, and socio-demographic characteristics were obtained from a nationally representative sample of 6365 adults. The number of accessible PA facilities per 1,000 individuals in each small area (data zones was obtained by mapping a representative list of all fixed PA facilities throughout mainland Scotland. A novel transport network was developed for the whole country, and routes on foot, by bike, by car and by bus from the weighted population centroid of each data zone to each facility were calculated. Separate multilevel models were fitted to examine associations between BMI and each of the 24 measures of accessibility of PA facilities and BMI, adjusting for age, gender, longstanding illness, car availability, social class, dietary quality and urban/rural classification. Results We found associations (p < 0.05 between BMI and 7 of the 24 accessibility measures, with mean BMI decreasing with increasing accessibility of facilities—for example, an estimated decrease of 0.015 BMI units per additional facility within a 20-min walk (p = 0.02. None of these accessibility measures were found to be associated with PA participation. Conclusions Our national study has shown that some measures of the accessibility of PA facilities by different modes of transport (particularly by walking and cycling were associated with BMI; but PA participation, as measured here, did not appear to

  8. Total-body irradiation and bone-marrow transplantation - first observations on clinical tolerance

    International Nuclear Information System (INIS)

    Gocheva, L.; Sergieva, K.; Koleva, I.; Mlachkova, D.; Michailov, G.; Avramova, B.

    2004-01-01

    About 50 000 bone-marrow transplantations (BMT) are performed annually at the present stage in numerous clinical centers all over the world. The Bulgarian experience in total-body irradiation (TBI) with following BMT is rather scarce. The routine TBI procedures in the oncological practice in the country date back just to 2001. The aim of the present publication is to describe the Bulgarian experience and the first impressions from the clinical tolerance of the total-body irradiation (TBI) with subsequent allogeneic peripheral stem cell transplantation (PSCT). Patient characteristics are presented in detail, including their distribution with respect to sex, age, primary diagnose, recurrence number till BMT, patient status during BMT performance (clinical hematological remission or relapse), as well as the basic parameters of the conditioning regime including TBI with subsequent allogeneic PSCT. The position of the patient and the applied radiotherapeutic equipment are described as well as the TBI schemes, respectively 5 fractions of 2 Gy per day for two patients and 3-day irradiation with 6 fractions (two fractions with a 6-hour interval between them) for the rest of the patients. The total dose (TD) of 10 Gy is realized for all patients. The clinical tolerance of 7 patients subjected to TBI and allogeneic PSCT is discussed. All patients were tolerable to the TBI treatment and had no serious problems. The radiotherapy was interrupted only in the case of the first two patients due to slight gastro-intestinal reactions. The first days of radiation were accompanied with a light degree of headache, nausea and vomiting, which were successfully overcome by granisetron. Diarrhea syndrome and mucositis to the II-III degree were developed subsequently without parotitis development. On the days 0 and +1 of the clinical protocol transplantation was realized of non- T-cell-depleted grafts (in 5 patients) and T-cell-depleted grafts (in 2 patients), which had no serious

  9. The use of Total Body In Vivo Neutron Activation Analysis (TBIVNAA) in balance studies in rodents

    International Nuclear Information System (INIS)

    Smith, D.A.; Lindsay, R.L.; Anderson, J.

    1976-01-01

    In the investigation of animals subject to alteration in diet or other metabolic experiments, the measurements of change in body calcium, phosphorus, sodium and nitrogen are of considerable interest. However, conventional balance studies are tedious and subject to both random and cumulative error, necessitating as they do accurate estimates of dietary intake and faecal and urinary output. The object of the present study was to determine the usefulness of total body in vivo neutron activation analysis, used at the beginning and end of the experimental period, as an alternative to conventional balance techniques. (orig.) [de

  10. High dietary protein intake is associated with an increased body weight and total death risk.

    Science.gov (United States)

    Hernández-Alonso, Pablo; Salas-Salvadó, Jordi; Ruiz-Canela, Miguel; Corella, Dolores; Estruch, Ramón; Fitó, Montserrat; Arós, Fernando; Gómez-Gracia, Enrique; Fiol, Miquel; Lapetra, José; Basora, Josep; Serra-Majem, Lluis; Muñoz, Miguel Ángel; Buil-Cosiales, Pilar; Saiz, Carmen; Bulló, Mònica

    2016-04-01

    High dietary protein diets are widely used to manage overweight and obesity. However, there is a lack of consensus about their long-term efficacy and safety. Therefore, the aim of this study was to assess the effect of long-term high-protein consumption on body weight changes and death outcomes in subjects at high cardiovascular risk. A secondary analysis of the PREDIMED trial was conducted. Dietary protein was assessed using a food-frequency questionnaire during the follow-up. Cox proportional hazard models were used to estimate the multivariate-adjusted hazard ratio (HR) and 95% confidence intervals (95%CI) for protein intake in relation to the risk of body weight and waist circumference changes, cardiovascular disease, cardiovascular death, cancer death and total death. Higher total protein intake, expressed as percentage of energy, was significantly associated with a greater risk of weight gain when protein replaced carbohydrates (HR: 1.90; 95%CI: 1.05, 3.46) but not when replaced fat (HR: 1.69; 95%CI: 0.94, 3.03). However, no association was found between protein intake and waist circumference. Contrary, higher total protein intake was associated with a greater risk of all-cause death in both carbohydrate and fat substitution models (HR: 1.59; 95%CI: 1.08, 2.35; and HR: 1.66; 95%CI: 1.13, 2.43, respectively). A higher consumption of animal protein was associated with an increased risk of fatal and non-fatal outcomes when protein substituted carbohydrates or fat. Higher dietary protein intake is associated with long-term increased risk of body weight gain and overall death in a Mediterranean population at high cardiovascular risk. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  11. Improving gross count gamma-ray logging in uranium mining with the NGRS probe

    Directory of Open Access Journals (Sweden)

    Carasco C.

    2018-01-01

    Full Text Available AREVA Mines and the Nuclear Measurement Laboratory of CEA Cadarache are collaborating to improve the sensitivity and precision of uranium concentration measurement by means of gamma ray logging. The determination of uranium concentration in boreholes is performed with the Natural Gamma Ray Sonde (NGRS based on a NaI(Tl scintillation detector. The total gamma count rate is converted into uranium concentration using a calibration coefficient measured in concrete blocks with known uranium concentration in the AREVA Mines calibration facility located in Bessines, France. Until now, to take into account gamma attenuation in a variety of boreholes diameters, tubing materials, diameters and thicknesses, filling fluid densities and compositions, a semi-empirical formula was used to correct the calibration coefficient measured in Bessines facility. In this work, we propose to use Monte Carlo simulations to improve gamma attenuation corrections. To this purpose, the NGRS probe and the calibration measurements in the standard concrete blocks have been modeled with MCNP computer code. The calibration coefficient determined by simulation, 5.3 s-1.ppmU-1 ± 10%, is in good agreement with the one measured in Bessines, 5.2 s-1.ppmU-1. Based on the validated MCNP model, several parametric studies have been performed. For instance, the rock density and chemical composition proved to have a limited impact on the calibration coefficient. However, gamma self-absorption in uranium leads to a nonlinear relationship between count rate and uranium concentration beyond approximately 1% of uranium weight fraction, the underestimation of the uranium content reaching more than a factor 2.5 for a 50 % uranium weight fraction. Next steps will concern parametric studies with different tubing materials, diameters and thicknesses, as well as different borehole filling fluids representative of real measurement conditions.

  12. Improving gross count gamma-ray logging in uranium mining with the NGRS probe

    Science.gov (United States)

    Carasco, C.; Pérot, B.; Ma, J.-L.; Toubon, H.; Dubille-Auchère, A.

    2018-01-01

    AREVA Mines and the Nuclear Measurement Laboratory of CEA Cadarache are collaborating to improve the sensitivity and precision of uranium concentration measurement by means of gamma ray logging. The determination of uranium concentration in boreholes is performed with the Natural Gamma Ray Sonde (NGRS) based on a NaI(Tl) scintillation detector. The total gamma count rate is converted into uranium concentration using a calibration coefficient measured in concrete blocks with known uranium concentration in the AREVA Mines calibration facility located in Bessines, France. Until now, to take into account gamma attenuation in a variety of boreholes diameters, tubing materials, diameters and thicknesses, filling fluid densities and compositions, a semi-empirical formula was used to correct the calibration coefficient measured in Bessines facility. In this work, we propose to use Monte Carlo simulations to improve gamma attenuation corrections. To this purpose, the NGRS probe and the calibration measurements in the standard concrete blocks have been modeled with MCNP computer code. The calibration coefficient determined by simulation, 5.3 s-1.ppmU-1 ± 10%, is in good agreement with the one measured in Bessines, 5.2 s-1.ppmU-1. Based on the validated MCNP model, several parametric studies have been performed. For instance, the rock density and chemical composition proved to have a limited impact on the calibration coefficient. However, gamma self-absorption in uranium leads to a nonlinear relationship between count rate and uranium concentration beyond approximately 1% of uranium weight fraction, the underestimation of the uranium content reaching more than a factor 2.5 for a 50 % uranium weight fraction. Next steps will concern parametric studies with different tubing materials, diameters and thicknesses, as well as different borehole filling fluids representative of real measurement conditions.

  13. [Study on modeling method of total viable count of fresh pork meat based on hyperspectral imaging system].

    Science.gov (United States)

    Wang, Wei; Peng, Yan-Kun; Zhang, Xiao-Li

    2010-02-01

    Once the total viable count (TVC) of bacteria in fresh pork meat exceeds a certain number, it will become pathogenic bacteria. The present paper is to explore the feasibility of hyperspectral imaging technology combined with relevant modeling method for the prediction of TVC in fresh pork meat. For the certain kind of problem that has remarkable nonlinear characteristic and contains few samples, as well as the problem that has large amount of data used to express the information of spectrum and space dimension, it is crucial to choose a logical modeling method in order to achieve good prediction result. Based on the comparative result of partial least-squares regression (PLSR), artificial neural networks (ANNs) and least square support vector machines (LS-SVM), the authors found that the PLSR method was helpless for nonlinear regression problem, and the ANNs method couldn't get approving prediction result for few samples problem, however the prediction models based on LS-SVM can give attention to the little training error and the favorable generalization ability as soon as possible, and can make them well synchronously. Therefore LS-SVM was adopted as the modeling method to predict the TVC of pork meat. Then the TVC prediction model was constructed using all the 512 wavelength data acquired by the hyperspectral imaging system. The determination coefficient between the TVC obtained with the standard plate count for bacterial colonies method and the LS-SVM prediction result was 0.987 2 and 0.942 6 for the samples of calibration set and prediction set respectively, also the root mean square error of calibration (RMSEC) and the root mean square error of prediction (RMSEP) was 0.207 1 and 0.217 6 individually, and the result was considerably better than that of MLR, PLSR and ANNs method. This research demonstrates that using the hyperspectral imaging system coupled with the LS-SVM modeling method is a valid means for quick and nondestructive determination of TVC of pork

  14. The role of total body irradiation in preparation for bone marrow transplantation in acute leukaemia. A review

    International Nuclear Information System (INIS)

    Zwaan, F.E.

    1979-01-01

    From extrapolation obtained from animal studies and radiation accidents, it is assumed that for man the LD 50 (30) will be between 300-500 rads total body irradiation (TBI) and the LD 100 at least 600 rads TBI. A dose of 1000 rads TBI is generally used in man for conditioning for bone marrow transplantation. In acute leukemia, total body irradiation is usually associated with cytoreductive chemotherapy. In Seattle 110 patients underwent bone marrow transplantation for acute leukemia in relapse. 15 patients became long term survivors. The main cause of failure were GVH, interstitial pneumonitis and leukemic relapse. New attempts are being made to improve the results: (1) better cytoreductive therapy preceding transplantation, (2) bone marrow transplantation during remission of the disease, (3) prevention of interstitial pneumonitis by modifications of the TBI technique

  15. Effect of the carbohydrate counting method on glycemic control in patients with type 1 diabetes

    Directory of Open Access Journals (Sweden)

    Dias Viviane M

    2010-08-01

    Full Text Available Abstract Background The importance of achieving and maintaining an appropriate metabolic control in patients with type 1 diabetes mellitus (DM1 has been established in many studies aiming to prevent the development of chronic complications. The carbohydrate counting method can be recommended as an additional tool in the nutritional treatment of diabetes, allowing patients with DM1 to have more flexible food choices. This study aimed to evaluate the influence of nutrition intervention and the use of multiple short-acting insulin according to the carbohydrate counting method on clinical and metabolic control in patients with DM1. Methods Our sample consisted of 51 patients with DM1, 32 females, aged 25.3 ± 1.55 years. A protocol of nutritional status evaluation was applied and laboratory analysis was performed at baseline and after a three-month intervention. After the analysis of the food records, a balanced diet was prescribed using the carbohydrate counting method, and short-acting insulin was prescribed based on the total amount of carbohydrate per meal (1 unit per 15 g of carbohydrate. Results A significant decrease in A1c levels was observed from baseline to the three-month evaluation after the intervention (10.40 ± 0.33% and 9.52 ± 0.32%, respectively, p = 0.000. It was observed an increase in daily insulin dose after the intervention (0.99 ± 0.65 IU/Kg and 1.05 ± 0.05 IU/Kg, respectively, p = 0.003. No significant differences were found regarding anthropometric evaluation (BMI, waist, hip or abdominal circumferences and waist to hip ratio after the intervention period. Conclusions The use of short-acting insulin based on the carbohydrate counting method after a short period of time resulted in a significant improvement of the glycemic control in patients with DM1 with no changes in body weight despite increases in the total daily insulin doses.

  16. Total proteins and protein fractions levels in pregnant rats subjected to whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Mansour, M.A.; Roushdy, H.M.; Mazhar, F.M.; Abu-Gabal, H.A.

    1986-01-01

    A total number of 180 mature rats (120 females and 60 males) weighing from 120-140 g were used to study the effect of two doses (2 and 4 Gy) whole-body gamma irradiation on the level of total protein and protein fractions in serum of pregnant rats during the period of organogenesis. It was found that the levels of total protein, albumin and gamma globulins significantly decreased according to the doses of exposure. The levels of alpha and beta globulins significantly increased more in the serum of rats exposed to 2 Gy than in rats exposed to 4 Gy. The level of A/G ratio significantly decreased more in the serum of rats exposed to 2Gy than in those exposed to 4 Gy

  17. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  18. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial

    NARCIS (Netherlands)

    Sierink, Joanne C.; Treskes, Kaij; Edwards, Michael J. R.; Beuker, Benn J. A.; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G. W.; Luitse, Jan S. K.; Beenen, Ludo F. M.; Hollmann, Markus W.; Goslings, J. Carel; Saltzherr, T. P.; Schep, N. W. L.; Streekstra, G. J.; van Lieshout, E. M. M.; Patka, P.; Klimek, M.; van Vugt, R.; Tromp, T. J. N.; Brink, M.; Harbers, J. S.; El Moumni, M.; Wendt, K. W.; Bingisser, R.; Ummenhofer, W.; Bless, N.

    2016-01-01

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in

  19. Busulfan and total body irradiation as antihematopoietic stem cell agents in the preparation of patients with congenital bone marrow disorders for allogenic bone marrow transplantation

    International Nuclear Information System (INIS)

    Parkman, R.; Rappeport, J.M.; Hellman, S.; Lipton, J.; Smith, B.; Geha, R.; Nathan, D.G.

    1984-01-01

    The capacity of busulfan and total body irradiation to ablate hematopoietic stem cells as preparation for the allogeneic bone marrow transplantation of patients with congenital bone marrow disorders was studied. Fourteen patients received 18 transplants; busulfan was used in the preparatory regimen of eight transplants and total body irradiation in the regimens of six transplants. Sustained hematopoietic ablation was achieved in six of eight patients prepared with busulfan and in all six patients prepared with total body irradiation. Three patients prepared with total body irradiation died with idiopathic interstitial pneumonitis, whereas no patients receiving busulfan developed interstitial pneumonitis. The optimal antihematopoietic stem cell agent to be used for the preparation of patients with congenital bone marrow disorder for bone marrow transplantation is not certain

  20. A 14 MeV neutron irradiation facility with an automated fast cyclic pneumatic

    International Nuclear Information System (INIS)

    Montgomery, M.T.; Yoho, M.D.; Biegalski, S.R.; Landsberger, S.; Welch, L.

    2016-01-01

    This work details the design criteria, construction, controls, and optimization of the 14 MeV neutron irradiation facility at the University of Texas, built with the motivation of performing neutron activation analysis on samples with short half-lives. The facility couples a D-T neutron generator with a pneumatic transfer system capable of transit of approximately one second between source and detector, while the cyclic automated nature allows for many irradiation/count trials with any number of samples, translating to significantly improved counting statistics. (author)