WorldWideScience

Sample records for total prescribed dose

  1. Pocket total dose meter

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.

    1984-10-01

    Laboratory measurements have demonstrated that it is possible to simultaneously measure absorbed dose and dose equivalent using a single tissue equivalent proportional counter. Small, pocket sized instruments are being developed to determine dose equivalent as the worker is exposed to mixed field radiation. This paper describes the electronic circuitry and computer algorithms used to determine dose equivalent in these devices

  2. Total dose meter development

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1986-09-01

    This report describes an alarming ''pocket'' monitor/dosimeter, based on a tissue-equivalent proportional counter, that measure both neutron and gamma dose and determines dose equivalent for the mixed radiation field. This report details the operation of the device and provides information on: the necessity for a device to measure dose equivalent in mixed radiation fields; the mathematical theory required to determine dose equivalent from tissue equivalent proportional; the detailed electronic circuits required; the algorithms required in the microprocessor used to calculate dose equivalent; the features of the instrument; program accomplishments and future plans

  3. A drug utilisation study investigating prescribed daily doses of ...

    African Journals Online (AJOL)

    and drug groups. Design. Retrospective drug utilisation study using data .... drugs that were prescribed 20 or fewer times during the period under ... occurs in women and men at different ages and with different severity. group. On average, men ...

  4. Comparison of Dose When Prescribed to Point A and Point H for Brachytherapy in Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gang, Ji Hyeong; Gim, Il Hwan; Hwang, Seon Boong; Kim, Woong; Im, Hyeong Seo; Gang, Jin Mook; Gim, Gi Hwan; Lee, Ah Ram [Dept. of Radiation Oncology, Korea Institute of Radiological and Medical Sciences, Seou (Korea, Republic of)

    2012-09-15

    The purpose of this study is to compare plans prescribed to point A with these prescribed to point H recommended by ABS (American Brachytherapy Society) in high dose rate intracavitary brachytherapy for cervical carcinoma. This study selected 103 patients who received HDR (High Dose Rate) brachytherapy using tandem and ovoids from March 2010 to January 2012. Point A, bladder point, and rectal point conform with Manchester System. Point H conforms with ABS recommendation. Also Sigmoid colon point, and vagina point were established arbitrarily. We examined distance between point A and point H. The percent dose at point A was calculated when 100% dose was prescribed to point H. Additionally, the percent dose at each reference points when dose is prescribed to point H and point A were calculated. The relative dose at point A was lower when point H was located inferior to point A. The relative doses at bladder, rectal, sigmoid colon, and vagina points were higher when point H was located superior to point A, and lower when point H was located inferior to point A. This study found out that as point H got located much superior to point A, the absorbed dose of surrounding normal organs became higher, and as point H got located much inferior to point A, the absorbed dose of surrounding normal organs became lower. This differences dose not seem to affect the treatment. However, we suggest this new point is worth being considered for the treatment of HDR if dose distribution and absorbed dose at normal organs have large differences between prescribed to point A and H.

  5. Dose absorbed in the fetus by radioactive drugs prescribed

    International Nuclear Information System (INIS)

    Rojo, A.M.; Gomez Parada, I.; Di Trano, J.L.

    1998-01-01

    This work aims to review existing guidelines on the hypothesis that must be taken into account when calculating impact from the dose on the fetus for widely employed radioactive drugs. Recent research is added giving data on placenta transference linked to pregnancy term. The most widely used diagnostic and therapeutic practices are analyzed comparing the dose impact on the fetus with limits internationally accepted. This will allow having the necessary tools to answer questions concerning radiological risks due to the administration of radioactive drugs to pregnant women

  6. Chinese Herbal Medicines – Comparison of Doses Prescribed in ...

    African Journals Online (AJOL)

    Huan Dong Lu, Beijing 100029, China. *For correspondence: Email: fuyanlingbucm@126.com; Tel: (+86) 10-6428-6307; Fax: (+86) 10-6422-0858 ... pharmacopoeia, accounting for 57.14 % (32/56). The top three factors influencing dose ... herbal combination, property of Chinese herbs, quality of medicinal, have a strong ...

  7. p-MOSFET total dose dosimeter

    Science.gov (United States)

    Buehler, Martin G. (Inventor); Blaes, Brent R. (Inventor)

    1994-01-01

    A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

  8. Assessment of individual dose utilization vs. physician prescribing recommendations for recombinant activated factor VII (rFVIIa) in paediatric and adult patients with congenital haemophilia and alloantibody inhibitors (CHwI): the Dosing Observational Study in Hemophilia (DOSE).

    Science.gov (United States)

    Gruppo, R A; Kessler, C M; Neufeld, E J; Cooper, D L

    2013-07-01

    Recent data from the Dosing Observational Study in Hemophilia diary study has described home treatment with recombinant activated factor VII (rFVIIa) in congenital haemophilia with inhibitors (CHwI). The current analysis compares prescribed and patient/caregiver-reported rFVIIa administration in paediatric and adult CHwI patients in this study. Patients with ≥ 4 bleeding episodes within a 3-month period prescribed rFVIIa as first-line therapy for bleeding episodes were eligible. Patients/caregivers completed a diary for ≥ 90 days or until the patient experienced four bleeds. Initial, total and mean rFVIIa doses reported for each bleeding episode were calculated and compared with the physician-prescribed doses. Of 52 enrolled patients (25 children; 27 adults), 39 (75%) completed the study. Children and adults had similar mean durations of bleeding episodes. Both patient groups were administered higher initial rFVIIa doses for joint bleeds than prescribed: median (range) 215.2 (74.1-400.0) mcg kg(-1) vs. 200.0 (61.0-270.0) mcg kg(-1) for children, and 231.3 (59.3-379.7) mcg kg(-1) vs. 123.0 (81.0-289.0) mcg kg(-1) for adults. The median infused dose for joint bleeds was higher in adults than children (175.2 vs. 148.0 mcg kg(-1) ), but children received significantly more doses per joint bleed than adults (median 6.5 vs. 3.0). The median total dose per joint bleed was higher in children than adults (1248.7 vs. 441.6). For children and adults, both initial and additional doses administered for bleeds were higher than prescribed. Children received higher total doses per bleed due to an increased number of infusions per bleed. © 2013 John Wiley & Sons Ltd.

  9. Theoretic simulation for CMOS device on total dose radiation response

    International Nuclear Information System (INIS)

    He Baoping; Zhou Heqin; Guo Hongxia; He Chaohui; Zhou Hui; Luo Yinhong; Zhang Fengqi

    2006-01-01

    Total dose effect is simulated for C4007B, CC4007RH and CC4011 devices at different absorbed dose rate by using linear system theory. When irradiation response and dose are linear, total dose radiation and post-irradiation annealing at room temperature are determined for one random by choosing absorbed dose rate, and total dose effect at other absorbed dose rate can be predicted by using linear system theory. The simulating results agree with the experimental results at different absorbed dose rate. (authors)

  10. Prescribing and evaluating target dose in dose-painting treatment plans

    DEFF Research Database (Denmark)

    Håkansson, Katrin; Specht, Lena; Aznar, Marianne C

    2014-01-01

    BACKGROUND: Assessment of target dose conformity in multi-dose-level treatment plans is challenging due to inevitable over/underdosage at the border zone between dose levels. Here, we evaluate different target dose prescription planning aims and approaches to evaluate the relative merit of such p......-painting and multi-dose-level plans. The tool can be useful for quality assurance of multi-center trials, and for visualizing the development of treatment planning in routine clinical practice....... of such plans. A quality volume histogram (QVH) tool for history-based evaluation is proposed. MATERIAL AND METHODS: Twenty head and neck cancer dose-painting plans with five prescription levels were evaluated, as well as clinically delivered simultaneous integrated boost (SIB) plans from 2010 and 2012. The QVH...

  11. High-Dose Opioid Prescribing and Opioid-Related Hospitalization: A Population-Based Study.

    Directory of Open Access Journals (Sweden)

    Kimberly Fernandes

    Full Text Available To examine the impact of national clinical practice guidelines and provincial drug policy interventions on prevalence of high-dose opioid prescribing and rates of hospitalization for opioid toxicity.Interventional time-series analysis.Ontario, Canada, from 2003 to 2014.Ontario Drug Benefit (ODB beneficiaries aged 15 to 64 years from 2003 to 2014.Publication of Canadian clinical practice guidelines for use of opioids in chronic non-cancer pain (May 2010 and implementation of Ontario's Narcotics Safety and Awareness Act (NSAA; November 2011.Three outcomes were explored: the rate of opioid use among ODB beneficiaries, the prevalence of opioid prescriptions exceeding 200 mg and 400 mg morphine equivalents per day, and rates of opioid-related emergency department visits and hospital admissions.Over the 12 year study period, the rate of opioid use declined 15.2%, from 2764 to 2342 users per 10,000 ODB eligible persons. The rate of opioid use was significantly impacted by the Canadian clinical practice guidelines (p-value = .03 which led to a decline in use, but no impact was observed by the enactment of the NSAA (p-value = .43. Among opioid users, the prevalence of high-dose prescribing doubled (from 4.2% to 8.7% over the study period. By 2014, 40.9% of recipients of long-acting opioids exceeded daily doses of 200 mg morphine or equivalent, including 55.8% of long-acting oxycodone users and 76.3% of transdermal fentanyl users. Moreover, in the last period, 18.7% of long-acting opioid users exceeded daily doses of 400 mg morphine or equivalent. Rates of opioid-related emergency department visits and hospital admissions increased 55.0% over the study period from 9.0 to 14.0 per 10,000 ODB beneficiaries from 2003 to 2013. This rate was not significantly impacted by the Canadian clinical practice guidelines (p-value = .68 or enactment of the NSAA (p-value = .59.Although the Canadian clinical practice guidelines for use of opioids in chronic non

  12. Airborne and total gamma absorbed dose rates at Patiala - India

    International Nuclear Information System (INIS)

    Tesfaye, Tilahun; Sahota, H.S.; Singh, K.

    1999-01-01

    The external gamma absorbed dose rate due to gamma rays originating from gamma emitting aerosols in air, is compared with the total external gamma absorbed dose rate at the Physics Department of Punjabi University, Patiala. It has been found out that the contribution, to the total external gamma absorbed dose rate, of radionuclides on particulate matter suspended in air is about 20% of the overall gamma absorbed dose rate. (author)

  13. Dose equivalent distributions in the AAEC total body nitrogen facility

    International Nuclear Information System (INIS)

    Allen, B.J.; Bailey, G.M.; McGregor, B.J.

    1985-01-01

    The incident neutron dose equivalent in the AAEC total body nitrogen facility is measured by a calibrated remmeter. Dose equivalent rates and distributions are calculated by Monte Carlo techniques which take account of the secondary neutron flux from the collimator. Experiment and calculation are found to be in satisfactory agreement. The effective dose equivalent per exposure is determined by weighting organ doses, and the potential detriment per exposure is calculated from ICRP risk factors

  14. Correct statistical evaluation for total dose in rural settlement

    International Nuclear Information System (INIS)

    Vlasova, N.G.; Skryabin, A.M.

    2001-01-01

    Statistical evaluation of dose reduced to the determination of an average value and its error. If an average value of a total dose in general can be determined by simple summarizing of the averages of its external and internal components, the evaluation of an error can be received only from its distribution. Herewith, considering that both components of the dose are interdependent, to summarize their distributions, as a last ones of a random independent variables, is incorrect. It follows that an evaluation of the parameters of the total dose distribution, including an error, in general, cannot be received empirically, particularly, at the lack or absence of the data on one of the components of the last one, that constantly is happens in practice. If the evaluation of an average for total dose was defined somehow, as the best, as an average of a distribution of the values of individual total doses, as summarizing the individual external and internal doses by the random type, that an error of evaluation had not been produced. The methodical approach to evaluation of the total dose distribution at the lack of dosimetric information was designed. The essence of it is original way of an interpolation of an external dose distribution, using data on an internal dose

  15. Compliance to the prescribed dose and overall treatment time in five randomized clinical trials of altered fractionation in radiotherapy for head-and-neck carcinomas

    International Nuclear Information System (INIS)

    Khalil, Azza A.; Bentzen, Soeren M.; Bernier, Jacques; Saunders, Michele I.; Horiot, Jean-Claude; Bogaert, Walter van den; Cummings, Bernard J.; Dische, Stanley

    2003-01-01

    Purpose: To investigate compliance to the prescribed dose-fractionation schedule in five randomized controlled trials of altered fractionation in radiotherapy for head-and-neck carcinoma. Methods and Materials: Individual patient data from 2566 patients participating in the European Organization for Research and Treatment of Cancer (EORTC) 22791, EORTC 22811, EORTC 22851, Princess Margaret Hospital (PMH), and continuous hyperfractionated accelerated radiotherapy (CHART) head-and-neck trials were merged in the fractionation IMPACT (Intergroup Merger of Patient data from Altered or Conventional Treatment schedules) study database. The ideal treatment time was defined as the minimum time required to deliver a prescribed schedule. Compliance to the prescribed overall treatment time was quantified as the difference between the actual and the ideal overall time. An overall measure of compliance in an individual patient, the total dose lost (TDL), was calculated as the dose lost due to prolongation of therapy (assuming a D prolif of 0.64 Gy/day) plus the difference between the prescribed and the actual dose given. Results: The time in excess of the ideal ranged up to 97 days (average 3.9 days), and 25% of the patients had delays of 6 days or more. World Health Organization (WHO) performance status and nodal stage had a significant effect on TDL. TDL was significantly higher in the conventional than in the altered arm of the EORTC 22851 and CHART trials. In the PMH trial, TDL was significantly higher in the hyperfractionation than in the conventional arm. Centers participating in the three EORTC trials varied significantly in their compliance. There was a significant improvement in compliance in patients treated more recently. Conclusions: Even in randomized controlled trials, compliance to the prescribed radiation therapy schedule may be relatively poor, especially after conventional fractionation. This affects the interpretation of the outcome of these trials

  16. Simulation experiment on total ionization dose effects of linear CCD

    International Nuclear Information System (INIS)

    Tang Benqi; Zhang Yong; Xiao Zhigang; Wang Zujun; Huang Shaoyan

    2004-01-01

    We carry out the ionization radiation experiment of linear CCDs operated in unbiased, biased, biased and driven mode respectively by Co-60 γ source with our self-designed test system, and offline test the Dark signal and Saturation voltage and SNR varied with total dose for TCD132D, and get some valuable results. On the basis of above work, we set forth a primary experiment approaches to simulate the total dose radiation effects of charge coupled devices. (authors)

  17. Dependence of total dose response of bipolar linear microcircuits on applied dose rate

    International Nuclear Information System (INIS)

    McClure, S.; Will, W.; Perry, G.; Pease, R.L.

    1994-01-01

    The effect of dose rate on the total dose radiation hardness of three commercial bipolar linear microcircuits is investigated. Total dose tests of linear bipolar microcircuits show larger degradation at 0.167 rad/s than at 90 rad/s even after the high dose rate test is followed by a room temperature plus a 100 C anneal. No systematic correlation could be found for degradation at low dose rate versus high dose rate and anneal. Comparison of the low dose rate with the high dose rate anneal data indicates that MIL-STD-883, method 1019.4 is not a worst-case test method when applied to bipolar microcircuits for low dose rate space applications

  18. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  19. Pulsed total dose damage effect experimental study on EPROM

    International Nuclear Information System (INIS)

    Luo Yinhong; Yao Zhibin; Zhang Fengqi; Guo Hongxia; Zhang Keying; Wang Yuanming; He Baoping

    2011-01-01

    Nowadays, memory radiation effect study mainly focus on functionality measurement. Measurable parameters is few in china. According to the present situation, threshold voltage testing method was presented on floating gate EPROM memory. Experimental study of pulsed total dose effect on EPROM threshold voltage was carried out. Damage mechanism was analysed The experiment results showed that memory cell threshold voltage negative shift was caused by pulsed total dose, memory cell threshold voltage shift is basically coincident under steady bias supply and no bias supply. (authors)

  20. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  1. Methods of assessing total doses integrated across pathways

    International Nuclear Information System (INIS)

    Grzechnik, M.; Camplin, W.; Clyne, F.; Allott, R.; Webbe-Wood, D.

    2006-01-01

    Calculated doses for comparison with limits resulting from discharges into the environment should be summed across all relevant pathways and food groups to ensure adequate protection. Current methodology for assessments used in the radioactivity in Food and the Environment (R.I.F.E.) reports separate doses from pathways related to liquid discharges of radioactivity to the environment from those due to gaseous releases. Surveys of local inhabitant food consumption and occupancy rates are conducted in the vicinity of nuclear sites. Information has been recorded in an integrated way, such that the data for each individual is recorded for all pathways of interest. These can include consumption of foods, such as fish, crustaceans, molluscs, fruit and vegetables, milk and meats. Occupancy times over beach sediments and time spent in close proximity to the site is also recorded for inclusion of external and inhalation radiation dose pathways. The integrated habits survey data may be combined with monitored environmental radionuclide concentrations to calculate total dose. The criteria for successful adoption of a method for this calculation were: Reproducibility can others easily use the approach and reassess doses? Rigour and realism how good is the match with reality?Transparency a measure of the ease with which others can understand how the calculations are performed and what they mean. Homogeneity is the group receiving the dose relatively homogeneous with respect to age, diet and those aspects that affect the dose received? Five methods of total dose calculation were compared and ranked according to their suitability. Each method was labelled (A to E) and given a short, relevant name for identification. The methods are described below; A) Individual doses to individuals are calculated and critical group selection is dependent on dose received. B) Individual Plus As in A, but consumption and occupancy rates for high dose is used to derive rates for application in

  2. Study of total ionization dose effects in electronic devices

    International Nuclear Information System (INIS)

    Nidhin, T.S.; Bhattacharyya, Anindya; Gour, Aditya; Behera, R.P.; Jayanthi, T.

    2018-01-01

    Radiation effects in electronic devices are a major challenge in the dependable application developments of nuclear power plant instrumentation and control systems. The main radiation effects are total ionization dose (TID) effects, displacement damage dose (DDD) effects and single event effects (SEE). In this study, we are concentrating on TID effects in electronic devices. The focus of the study is mainly on SRAM based field programmable gate arrays (FPGA) along with that the devices of our interest are voltage regulators, flash memory and optocoupler. The experiments are conducted by exposing the devices to gamma radiation in power off condition and the degradation in the performances are analysed

  3. Dose rate and dose fractionation studies in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.

    1979-01-01

    Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients

  4. An improved standard total dose test for CMOS space electronics

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Winokur, P.S.; Riewe, L.C.; Pease, R.L.

    1989-01-01

    The postirradiation response of hardened and commercial CMOS devices is investigated as a function of total dose, dose rate, and annealing time and temperature. Cobalt-60 irradiation at ≅ 200 rad(SiO 2 )/s followed by a 1-week 100 degrees C biased anneal and testing is shown to be an effective screen of hardened devices for space use. However, a similar screen and single-point test performed after Co-60 irradiation and elevated temperature anneal cannot be generally defined for commercial devices. In the absence of detailed knowledge about device and circuit radiation response, a two-point standard test is proposed to ensure space surviability of CMOS circuits: a Co-60 irradiation and test to screen against oxide-trapped charge related failures, and an additional rebound test to screen against interface-trap related failures. Testing implications for bipolar technologies are also discussed

  5. Total dose and dose rate models for bipolar transistors in circuit simulation.

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Phillip Montgomery; Wix, Steven D.

    2013-05-01

    The objective of this work is to develop a model for total dose effects in bipolar junction transistors for use in circuit simulation. The components of the model are an electrical model of device performance that includes the effects of trapped charge on device behavior, and a model that calculates the trapped charge densities in a specific device structure as a function of radiation dose and dose rate. Simulations based on this model are found to agree well with measurements on a number of devices for which data are available.

  6. Theoretical considerations for SRAM total-dose hardening

    International Nuclear Information System (INIS)

    Francis, P.; Flandre, D.; Colinge, J.P.

    1995-01-01

    The theoretical hardness against total dose of the six-transistor SRAM cell is investigated in detail. An explicit analytical expression of the maximum tolerable threshold voltage shift is derived for two cross-coupled inverters. A numerical method is used to explore the hardness of the read and write operations. Both N- and P-channel access transistors designs are considered and their respective advantages are compared. The study points out that the radiation hardness mainly relies on the technology. Results obtained with the very robust Gate-All-Around process are finally presented

  7. Total effective dose equivalent associated with fixed uranium surface contamination

    International Nuclear Information System (INIS)

    Bogard, J.S.; Hamm, R.N.; Ashley, J.C.; Turner, J.E.; England, C.A.; Swenson, D.E.; Brown, K.S.

    1997-04-01

    This report provides the technical basis for establishing a uranium fixed-contamination action level, a fixed uranium surface contamination level exceeding the total radioactivity values of Appendix D of Title 10, Code of Federal Regulations, part 835 (10CFR835), but below which the monitoring, posting, and control requirements for Radiological Areas are not required for the area of the contamination. An area of fixed uranium contamination between 1,000 dpm/100 cm 2 and that level corresponding to an annual total effective dose equivalent (TEDE) of 100 mrem requires only routine monitoring, posting to alert personnel of the contamination, and administrative control. The more extensive requirements for monitoring, posting, and control designated by 10CFR835 for Radiological Areas do not have to be applied for these intermediate fixed-contamination levels

  8. Dose-escalated total body irradiation and autologous stem cell transplantation for refractory hematologic malignancy

    International Nuclear Information System (INIS)

    McAfee, Steven L.; Powell, Simon N.; Colby, Christine; Spitzer, Thomas R.

    2002-01-01

    Purpose: To evaluate the feasibility of dose escalation of total body irradiation (TBI) above the previously reported maximally tolerated dose, we have undertaken a Phase I-II trial of dose-escalated TBI with autologous peripheral blood stem cell transplantation (PBSCT) for chemotherapy-refractory lymphoma. Methods and Materials: Nine lymphoma patients with primary refractory disease (PRD) or in resistant relapse (RR) received dose-escalated TBI and PBSCT. The three dose levels of fractionated TBI (200 cGy twice daily) were 1,600 cGy, 1,800 cGy, and 2,000 cGy. Lung blocks were used to reduce the TBI transmission dose by 50%, and the chest wall dose was supplemented to the prescribed dose using electrons. Shielding of the kidneys was performed to keep the maximal renal dose at 1,600 cGy. Three patients, two with non-Hodgkin's lymphoma (NHL) in RR and one with PRD Hodgkin's disease, received 1,600 cGy + PBSCT, three patients (two NHL in RR, one PRD) received 1,800 cGy + PBSCT, and three patients with NHL (two in RR, one PRD) received 2,000 cGy + PBSCT. Results: Toxicities associated with this high-dose TBI regimen included reversible hepatic veno-occlusive disease in 1 patient, Grade 2 mucositis requiring narcotic analgesics in 8 patients, and neurologic toxicities consisting of a symmetrical sensory neuropathy (n=4) and Lhermitte's syndrome (n=1). Interstitial pneumonitis developed in 1 patient who received 1,800 cGy after receiving recombinant α-interferon (with exacerbation after rechallenge with interferon). Six (66%) patients achieved a response. Four (44%) patients achieved complete responses, three of which were of a duration greater than 1 year, and 2 (22%) patients achieved a partial response. One patient remains disease-free more than 5 years posttransplant. Corticosteroid-induced gastritis and postoperative infection resulted in the death of 1 patient in complete response, 429 days posttransplant. Conclusion: TBI in a dose range 1,600-2,000 cGy as

  9. Secondary radiation dose during high-energy total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Janiszewska, M.; Raczkowski, M. [Lower Silesian Oncology Center, Medical Physics Department, Wroclaw (Poland); Polaczek-Grelik, K. [University of Silesia, Medical Physics Department, Katowice (Poland); Szafron, B.; Konefal, A.; Zipper, W. [University of Silesia, Department of Nuclear Physics and Its Applications, Katowice (Poland)

    2014-05-15

    The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: {sup 56}Mn in the stainless steel and {sup 187}W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 μSv from activated radionuclides. Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once. (orig.) [German] Die zusaetzliche Dosis durch sekundaere Neutronen- und γ-Strahlung waehrend der Ganzkoerperbestrahlung mit Roentgenstrahlung aus medizinischen Linearbeschleunigern wurde abgeschaetzt. Bei der Emission hochenergetischer Strahlen zur Teletherapie finden hauptsaechlich im Beschleuniger

  10. Total Risk Management for Low Dose Radiation Exposures

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; Sterc, D.

    2012-01-01

    health. This view is supported with numerous evidences, and explained with beneficial effects from the increased activity of immune system activated with small radiation exposures. Finally, theory in between is that small doses are less than linearly proportionally harmful and that they are presenting a much smaller risks than according to the LNT. This view is derived from the use of different evidences. Difficulties to find one single theory about effects of small radiation doses are related to existence of huge variability and uncertainty in the evidence data. This is very hard experimental and theoretical problem. It will require lots of additional research to reduce these uncertainties and find final theory. This might be too late for the number of people affected in different ways with current single most conservative LNT approach. The problem with the conservative LNT regulatory approach is resulting in enormous additional costs of nuclear energy and medical applications. Which is reasonable and acceptable during the regular operation when source is high and concentrated. But, this becomes unreasonable huge economic burden after accidents and for cleanups with nuclear facilities. Similar problem arises with restriction of medical examinations and treatments based on over conservative risk estimate. Special circumstances are with evacuated people from contaminated areas where they are on the one side saved from small radiation exposures, and on the other side exposed to years of life away from their home and with numerous direct and indirect additional risks (i.e., stress, social problems, etc.). It seems reasonable that some alternative (total) risk management approach might be much more suitable for this situation. Evacuation of people from contaminated area with small doses sources should not be done when that induces larger risks from even what is expected from radiation based on LNT. Similar total risk management could be also applied for with medical

  11. Analytical models for total dose ionization effects in MOS devices.

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Phillip Montgomery; Bogdan, Carolyn W.

    2008-08-01

    MOS devices are susceptible to damage by ionizing radiation due to charge buildup in gate, field and SOI buried oxides. Under positive bias holes created in the gate oxide will transport to the Si / SiO{sub 2} interface creating oxide-trapped charge. As a result of hole transport and trapping, hydrogen is liberated in the oxide which can create interface-trapped charge. The trapped charge will affect the threshold voltage and degrade the channel mobility. Neutralization of oxidetrapped charge by electron tunneling from the silicon and by thermal emission can take place over long periods of time. Neutralization of interface-trapped charge is not observed at room temperature. Analytical models are developed that account for the principal effects of total dose in MOS devices under different gate bias. The intent is to obtain closed-form solutions that can be used in circuit simulation. Expressions are derived for the aging effects of very low dose rate radiation over long time periods.

  12. Total Dose Effects on Bipolar Integrated Circuits at Low Temperature

    Science.gov (United States)

    Johnston, A. H.; Swimm, R. T.; Thorbourn, D. O.

    2012-01-01

    Total dose damage in bipolar integrated circuits is investigated at low temperature, along with the temperature dependence of the electrical parameters of internal transistors. Bandgap narrowing causes the gain of npn transistors to decrease far more at low temperature compared to pnp transistors, due to the large difference in emitter doping concentration. When irradiations are done at temperatures of -140 deg C, no damage occurs until devices are warmed to temperatures above -50 deg C. After warm-up, subsequent cooling shows that damage is then present at low temperature. This can be explained by the very strong temperature dependence of dispersive transport in the continuous-time-random-walk model for hole transport. For linear integrated circuits, low temperature operation is affected by the strong temperature dependence of npn transistors along with the higher sensitivity of lateral and substrate pnp transistors to radiation damage.

  13. In vivo dosimetry with semiconducting diodes for dose verification in total-body irradiation. A 10-year experience

    International Nuclear Information System (INIS)

    Ramm, U.; Licher, J.; Moog, J.; Scherf, C.; Kara, E.; Boettcher, H.D.; Roedel, C.; Mose, S.

    2008-01-01

    Background and purpose: for total-body irradiation (TBI) using the translation method, dose distribution cannot be computed with computer-assisted three-dimensional planning systems. Therefore, dose distribution has to be primarily estimated based on CT scans (beam-zone method) which is followed by in vivo measurements to ascertain a homogeneous dose delivery. The aim of this study was to clinically establish semiconductor probes as a simple and fast method to obtain an online verification of the dose at relevant points. Patients and methods: in 110 consecutively irradiated TBI patients (12.6 Gy, 2 x 1.8 Gy/day), six semiconductor probes were attached to the body surface at dose-relevant points (eye/head, neck, lung, navel). The mid-body point of the abdomen was defined as dose reference point. The speed of translation was optimized to definitively reach the prescribed dose in this point. Based on the entrance and exit doses, the mid-body doses at the other points were computed. The dose homogeneity in the entire target volume was determined comparing all measured data with the dose at the reference point. Results: after calibration of the semiconductor probes under treatment conditions the dose in selected points and the dose homogeneity in the target volume could be quantitatively specified. In the TBI patients, conformity of calculated and measured doses in the given points was achieved with small deviations of adequate accuracy. The data of 80% of the patients are within an uncertainty of ± 5%. Conclusion: during TBI using the translation method, dose distribution and dose homogeneity can be easily controlled in selected points by means of semiconductor probes. Semiconductor probes are recommended for further use in the physical evaluation of TBI. (orig.)

  14. Total-dose hardness assurance for low earth orbit

    International Nuclear Information System (INIS)

    Maurer, R.H.; Suter, J.J.

    1987-01-01

    The Low Earth Orbit radiation environment has two significant characteristics that make laboratory simulation exposures difficult: (1) a low dose rate and (2) many cycles of low dose accumulation followed by dose-free annealing. Hardness assurance considerations for this environment are discussed and related to data from the testing of Advanced Low Power Schottky and High-speed CMOS devices

  15. Drug Dosing in Patients with Renal Insufficiency in a Hospital Setting using Electronic Prescribing and Automated Reporting of Estimated Glomerular Filtration Rate

    DEFF Research Database (Denmark)

    Nielsen, Anita L.; Henriksen, Daniel Pilsgaard; Marinakis, Christianna

    2014-01-01

    In patients with impaired renal function, drug dose adjustment is often required. Non-adherence to clinical prescribing recommendations may result in severe adverse events. In previous studies, the prevalence rate of non-adherence to recommended dosing has been reported to be 19-67%. Using the cl...... decision support systems should be explored. This article is protected by copyright. All rights reserved....

  16. Non-intercepted dose errors in prescribing anti-neoplastic treatment

    DEFF Research Database (Denmark)

    Mattsson, T O; Holm, B; Michelsen, H

    2015-01-01

    BACKGROUND: The incidence of non-intercepted prescription errors and the risk factors involved, including the impact of computerised order entry (CPOE) systems on such errors, are unknown. Our objective was to determine the incidence, type, severity, and related risk factors of non-intercepted pr....... Strategies to prevent future prescription errors could usefully focus on integrated computerised systems that can aid dose calculations and reduce transcription errors between databases....

  17. Fixed-dose combinations at the front line of multimodal pain management: perspective of the nurse-prescriber

    Directory of Open Access Journals (Sweden)

    O'Brien J

    2013-02-01

    Full Text Available Joanne O’Brien,1 Joseph V Pergolizzi Jr,2 Mart van de Laar3, Hans-Ulrich Mellinghoff,4 Ignacio Morón Merchante,5 Srinivas Nalamachu,6 Serge Perrot,7 Robert B Raffa81Department of Pain Medicine, Beaumont Hospital, Beaumont, Dublin, Ireland; 2Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD; Association of Chronic Pain Patients, Houston, TX; Department of Pharmacology, Temple University School of Medicine, Philadelphia, PA, USA; 3Arthritis Center Twente, Enschede, The Netherlands; 4Department of Endocrinology, Diabetology and Osteology, Kantonsspital St Gallen, Switzerland; 5Centro de Salud Universitario Goya, Madrid, Spain; 6Kansas University Medical Center, Kansas City, and International Clinic Research, Leawood, KS, USA; 7Service de Médecine Interne et Consultation de la Douleur, Hôpital Hotel Dieu, Paris Descartes University, Paris, France; 8Department of Pharmaceutical Sciences, Temple University School of Pharmacy, Philadelphia PA, USAAbstract: Pain should be treated promptly and effectively to restore the patient to full function, avoid pain chronification, and preserve quality of life. A recent pain specialists' meeting discussed the use of different pharmacological treatment options, such as topical analgesics, nonopioid agents (such as paracetamol and nonsteroidal anti-inflammatory drugs, weak and strong opioids, and fixed-dose combination products in the management of moderate to severe pain from different etiologies. One of the topics discussed in, and subsequent to, this meeting was the role of fixed-dose combination products for nurse-prescribers who are in many ways at the front line of managing both acute and chronic pain syndromes. The panel agreed that proper product selection should take into account the patient's age, condition, type of pain, and comorbidities, as well as balance safety with effectiveness. Although nurse-prescribers need to be aware of cumulative paracetamol dosing, fixed-dose

  18. Effects of total dose of ionizing radiation on integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marcilei A.G.; Cirne, K.H.; Gimenez, S.; Santos, R.B.B. [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil); Added, N.; Barbosa, M.D.L.; Medina, N.H.; Tabacniks, M.H. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Lima, J.A. de; Seixas Junior, L.E.; Melo, W. [Centro de Tecnologia da Informacao Paulo Archer, Sao Paulo, SP (Brazil)

    2011-07-01

    Full text: The study of ionizing radiation effects on materials used in electronic devices is of great relevance for the progress of global technological development and, particularly, it is a necessity in some strategic areas in Brazil. Electronic circuits are strongly influenced by radiation and the need for IC's featuring radiation hardness is largely growing to meet the stringent environment in space electronics. On the other hand, aerospace agencies are encouraging both scientific community and semiconductors industry to develop hardened-by-design components using standard manufacturing processes to achieve maximum performance, while significantly reducing costs. To understand the physical phenomena responsible for changes in devices exposed to ionizing radiation several kinds of radiation should then be considered, among them alpha particles, protons, gamma and X-rays. Radiation effects on the integrated circuits are usually divided into two categories: total ionizing dose (TID), a cumulative dose that shifts the threshold voltage and increases transistor's off-state current; single events effects (SEE), a transient effect which can deposit charge directly into the device and disturb the properties of electronic circuits. TID is one of the most common effects and may generate degradation in some parameters of the CMOS electronic devices, such as the threshold voltage oscillation, increase of the sub-threshold slope and increase of the off-state current. The effects of ionizing radiation are the creation of electron-hole pairs in the oxide layer changing operation mode parameters of the electronic device. Indirectly, there will be also changes in the device due to the formation of secondary electrons from the interaction of electromagnetic radiation with the material, since the charge carriers can be trapped both in the oxide layer and in the interface with the oxide. In this work we have investigated the behavior of MOSFET devices fabricated with

  19. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    International Nuclear Information System (INIS)

    Fritz, T.E.; Norris, W.P.; Tolle, D.V.; Seed, T.M.; Poole, C.M.; Lombard, L.S.; Doyle, D.E.

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to 60 Co γ rays in a specially constructed facility. The exposure rates were either 5, 10, 17, or 35 R/day, and the exposures were terminated at either 600, 1400, 2000, or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD 50 for γ-ray exposures given at a number of exposure rates. They also allow comparison of the relative importance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD 50 for the beagle increases from 258 rad delivered at 15 R/minute to approximately 3000 rad at 10 R/day. Over this entire range, the LD 50 is dependent upon hematopoietic damage. At 5 R/day and less, no meaningful LD 50 can be determined; there is nearly normal continued hematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in other organ systems. Although the experiment is not complete, interim data allow several important conclusions. Terminated exposures, while not as effective as radiation continued until death, can produce myelogenous leukemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates are more damaging than higher rates on the basis of the rate and degree of hematological recovery that occurs after termination of irradiation. Thus, the rate of hematologic depression, the nadir of the depression, and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the former two are directly related to exposure rate

  20. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    International Nuclear Information System (INIS)

    Fritz, T.E.; Norris, W.P.; Tolle, D.V.; Seed, T.M.; Poole, C.M.; Lombard, L.S.; Doyle, D.E.

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to 60 Co gamma rays in a specially constructed facility. The exposure rates were 5, 19, 17 or 35 R/day, and the exposures were terminated at 600, 1400, 2000 or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD 50 for gamma-ray exposures given at a number of exposure rates. They also allow comparison of the relativeimportance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD 50 for the beagle increases from 344 R (258 rads) delivered at 15 R/minute to approximately 4000 R (approximately 3000 rads) at 10 R/day. Over this entire range, the LD 50 is dependent upon haematopoietic damage. At 5 R/day and less, no definitive LD 50 can be determined; there is nearly normal continued haematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in the organ systems. Although the experiment is not complete, interim data allow serveral important conclusions. Terminated exposures, while not as effective as irradiation continued until death, can produce myelogenous leukaemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates appear more damaging than higher rates on the basis of the rate and degree of haematological recovery that occurs after termination of irradiation. Thus, the rate of haematologic depression, the nadir of the depression and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the first two are directly related to exposure rate. ( author)

  1. New Insights into Fully-Depleted SOI Transistor Response During Total Dose Irradiation

    International Nuclear Information System (INIS)

    Burns, J.A.; Dodd, P.E.; Keast, C.L.; Schwank, J.R.; Shaneyfelt, M.R.; Wyatt, P.W.

    1999-01-01

    Worst-case bias configuration for total-dose testing fully-depleted SOI transistors was found to be process dependent. No evidence was found for total-dose induced snap back. These results have implications for hardness assurance testing

  2. Dose compensation of the total body irradiation therapy

    International Nuclear Information System (INIS)

    Lin, J.-P.; Chu, T.-C.; Liu, M.-T.

    2001-01-01

    The aim of the study is to improve dose uniformity in the body by the compensator-rice and to decrease the dose to the lung by the partial lung block. Rando phantom supine was set up to treat bilateral fields with a 15 MV linear accelerator at 415 cm treatment distance. The experimental procedure included three parts. The first part was the bilateral irradiation without rice compensator, and the second part was with rice compensator. In the third part, rice compensator and partial lung block were both used. The results of thermoluminescent dosimeters measurements indicated that without rice compensator the dose was non-uniform. Contrarily, the average dose homogeneity with rice compensator was measured within ±5%, except for the thorax region. Partial lung block can reduce the dose which the lung received. This is a simple method to improve the dose homogeneity and to reduce the lung dose received. The compensator-rice is cheap, and acrylic boxes are easy to obtain. Therefore, this technique is suitable for more studies

  3. The difference between actual and prescribed weight bearing of total hip patients with a trochanteric osteotomy: long-term vertical force measurements inside and outside the hospital

    NARCIS (Netherlands)

    H.L.P. Hurkmans (Henri); J.B.J. Bussmann (Hans); R.W. Selles (Ruud); E. Benda (Eric); H.J. Stam (Henk); J.A.N. Verhaar (Jan)

    2007-01-01

    textabstractOBJECTIVE: To determine whether patients load the operated leg at a prescribed weight-bearing target load during postoperative recovery. DESIGN: A descriptive prospective study. SETTING: Orthopedic clinic and patients' homes. PARTICIPANTS: Fifty patients who had undergone total hip

  4. Total dose and dose rate radiation characterization of EPI-CMOS radiation hardened memory and microprocessor devices

    International Nuclear Information System (INIS)

    Gingerich, B.L.; Hermsen, J.M.; Lee, J.C.; Schroeder, J.E.

    1984-01-01

    The process, circuit discription, and total dose radiation characteristics are presented for two second generation hardened 4K EPI-CMOS RAMs and a first generation 80C85 microprocessor. Total dose radiation performance is presented to 10M rad-Si and effects of biasing and operating conditions are discussed. The dose rate sensitivity of the 4K RAMs is also presented along with single event upset (SEU) test data

  5. Evaluation of accelerated test parameters for CMOS IC total dose hardness prediction

    International Nuclear Information System (INIS)

    Sogoyan, A.V.; Nikiforov, A.Y.; Chumakov, A.I.

    1999-01-01

    The approach to accelerated test parameters evaluation is presented in order to predict CMOS IC total dose behavior in variable dose-rate environment. The technique is based on the analytical model of MOSFET parameters total dose degradation. The simple way to estimate model parameter is proposed using IC's input-output MOSFET radiation test results. (authors)

  6. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  7. Use of an electron reflector to improve dose uniformity at the vertex during total skin electron therapy

    International Nuclear Information System (INIS)

    Peters, V.G.

    2000-01-01

    Purpose: The vertex of the scalp is always tangentially irradiated during total skin electron therapy (TSET). This study was conducted to determine the dose distribution at the vertex for a commonly used irradiation technique and to evaluate the use of an electron reflector, positioned above the head, as a means of improving the dose uniformity. Methods and Materials: Phantoms, simulating the head of a patient, were irradiated using our standard procedure for TSET. The technique is a six-field irradiation using dual angled electron beams at a treatment distance of 3.6 meters. Vertex dosimetry was performed using ionization methods and film. Measurements were made for an unmodified 6 MeV electron beam and for a 4 MeV beam obtained by placing an acrylic scattering plate in the beam line. Studies were performed to examine the effect of electron scattering on vertex dose when a lead reflector, 50 x 50 cm in area, was positioned above the phantom. Results: The surface dose at the vertex, in the absence of the reflector, was found to be less than 40% of the prescribed skin dose. Use of the lead reflector increased this value to 73% for the 6 MeV beam and 99% for the degraded 4 MeV beam. Significant improvements in depth dose were also observed. The dose enhancement is not strongly dependent on reflector distance or angulation since the reflector acts as a large source of broadly scattered electrons. Conclusion: The vertex may be significantly underdosed using standard techniques for total skin electron therapy. Use of an electron reflector improves the dose uniformity at the vertex and may reduce or eliminate the need for supplemental irradiation

  8. Marrow toxicity of fractionated vs. single dose total body irradiation is identical in a canine model

    International Nuclear Information System (INIS)

    Storb, R.; Raff, R.F.; Graham, T.; Appelbaum, F.R.; Deeg, H.J.; Schuening, F.G.; Shulman, H.; Pepe, M.

    1993-01-01

    The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing 60 Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionated total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs

  9. Compendium of Total Ionizing Dose and Displacement Damage for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    Cochran, Donna J.; Boutte, Alvin J.; Chen, Dakai; Pellish, Jonathan A.; Ladbury, Raymond L.; Casey, Megan C.; Campola, Michael J.; Wilcox, Edward P.; Obryan, Martha V.; LaBel, Kenneth A.; hide

    2012-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear, and hybrid devices.

  10. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    International Nuclear Information System (INIS)

    Flickinger, J.C.; Kalend, A.

    1990-01-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab

  11. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Flickinger, J C; Kalend, A [Pittsburgh University School of Medicine (USA). Department of Radiation Oncology Pittsburg Cancer Institute (USA)

    1990-03-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab.

  12. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  13. Impact of total ionizing dose on the electromagnetic susceptibility of a single bipolar transistor

    International Nuclear Information System (INIS)

    Doridant, A.; Jarrix, S.; Raoult, J.; Blain, A.; Dusseau, L.; Chatry, N.; Calvel, P.; Hoffmann, P.

    2012-01-01

    Space or military electronic components are subject to both electromagnetic fields and total ionizing dose. This paper deals with the electromagnetic susceptibility of a discrete low frequency transistor subject to total ionizing dose deposition. The electromagnetic susceptibility is investigated on both non-irradiated and irradiated transistors mounted in common emitter configuration. The change in susceptibility to 100 MHz-1.5 GHz interferences lights up a synergy effect between near field electromagnetic waves and total ionizing dose. Physical mechanisms leading to changes in signal output are detailed. (authors)

  14. Low-dose total skin electron beam therapy for cutaneous lymphoma : Minimal risk of acute toxicities.

    Science.gov (United States)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor

    2017-12-01

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T‑cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses.

  15. Determination of the total indicative dose in drinking and mineral waters

    International Nuclear Information System (INIS)

    Flesch, K.; Schulz, H.; Knappik, R.; Koehler, M.

    2006-01-01

    In Europe and Germany administrative regulations exist for the surveillance of the total indicative dose of water supplied for human consumption. This parameter, which cannot be analyzed directly, has to be calculated using nuclide specific activity concentration and age specific dose conversion factors and consumption rates. Available calculation methods differ regarding the used radionuclides, consumption rates and whether they use age specific dose conversion factors or not. In Germany administrative guidelines for the determination of the total indicative dose are still not available. As they have analyzed a large number of waters in the past, the authors derive a praxis orientated concept for the determination of the total indicative dose which respects radiological, analytical and hydrochemical aspects as well. Finally it is suggested to handle sparkling waters in the same manner as drinking waters. (orig.)

  16. Simulation of Shielding Effects on the Total Dose Observed in TDE of KISAT-1

    Directory of Open Access Journals (Sweden)

    Sung-Joon Kim

    2001-06-01

    Full Text Available The threshold voltage shift observed in TDE (Total Dose Experiment on board the KITSAT-1 is converted into dose (rad(SiO2 usinsg the result of laboratory calibration with Co-60 gamma ray source in KAERI (Korea Atomic Energy Research Institute. Simulation using the NASA radiation model of geomagnetosphere verifies that the dose difference between RADFET1 and RADFET3 observed on KITSAT-1 comes from the difference in shielding thickness at the position of these RADFETs.

  17. Effect of γ-dose rate and total dose interrelation on the polymeric hydrogel: A novel injectable male contraceptive

    International Nuclear Information System (INIS)

    Jha, Pradeep K.; Jha, Rakhi; Gupta, B.L.; Guha, Sujoy K.

    2010-01-01

    Functional necessity to use a particular range of dose rate and total dose of γ-initiated polymerization to manufacture a novel polymeric hydrogel RISUG (reversible inhibition of sperm under guidance) made of styrene maleic anhydride (SMA) dissolved in dimethyl sulphoxide (DMSO), for its broad biomedical application explores new dimension of research. The present work involves 16 irradiated samples. They were tested by fourier transform infrared spectroscopy, matrix assisted laser desorption/ionization-TOF, field emission scanning electron microscopy, high resolution transmission electron microscopy, etc. to see the interrelation effect of gamma dose rates (8.25, 17.29, 20.01 and 25.00 Gy/min) and four sets of doses (1.8, 2.0, 2.2 and 2.4 kGy) on the molecular weight, molecular weight distribution and porosity analysis of the biopolymeric drug RISUG. The results of randomized experiment indicated that a range of 18-24 Gy/min γ-dose rate and 2.0-2.4 kGy γ-total doses is suitable for the desirable in vivo performance of the contraceptive copolymer.

  18. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  19. Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA GSFC and NEPP

    Science.gov (United States)

    Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Label, Kenneth A.; Cochran, Donna J.; O'Bryan, Martha V.

    2017-01-01

    Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include opto-electronics, digital, analog, linear bipolar devices, and hybrid devices.

  20. Recent Total Ionizing Dose and Displacement Damage Compendium of Candidate Electronics for NASA Space Systems

    Science.gov (United States)

    Cochran, Donna J.; Boutte, Alvin J.; Campola, Michael J.; Carts, Martin A.; Casey, Megan C.; Chen, Dakai; LaBel, Kenneth A.; Ladbury, Raymond L.; Lauenstein, Jean-Marie; Marshall, Cheryl J.; hide

    2011-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.

  1. The Role of Electron Transport and Trapping in MOS Total-Dose Modeling

    International Nuclear Information System (INIS)

    Flament, O.; Fleetwood, D.M.; Leray, J.L.; Paillet, P.; Riewe, L.C.; Winokur, P.S.

    1999-01-01

    Deep and shallow electron traps form in irradiated thermal SiO 2 as a natural response to hole transport and trapping. The density and stability of these defects are discussed, as are their implications for total-dose modeling

  2. Total dose effects on the matching properties of deep submicron MOS transistors

    International Nuclear Information System (INIS)

    Wang Yuxin; Hu Rongbin; Li Ruzhang; Chen Guangbing; Fu Dongbing; Lu Wu

    2014-01-01

    Based on 0.18 μm MOS transistors, for the first time, the total dose effects on the matching properties of deep submicron MOS transistors are studied. The experimental results show that the total dose radiation magnifies the mismatch among identically designed MOS transistors. In our experiments, as the radiation total dose rises to 200 krad, the threshold voltage and drain current mismatch percentages of NMOS transistors increase from 0.55% and 1.4% before radiation to 17.4% and 13.5% after radiation, respectively. PMOS transistors seem to be resistant to radiation damage. For all the range of radiation total dose, the threshold voltage and drain current mismatch percentages of PMOS transistors keep under 0.5% and 2.72%, respectively. (semiconductor devices)

  3. Analysis of Surface Dose Refer to Distance between Beam Spoiler and Patient in Total Body Irradiation

    International Nuclear Information System (INIS)

    Choi, Jong Hwan; Kim, Jong Sik; Choi, Ji Min; Shin, Eun Hyuk; Song, Ki Won; Park, Young Hwan

    2007-01-01

    Total body irradiation is used to kill the total malignant cell and for immunosuppression component of preparatory regimens for bone-marrow restitution of patients. Beam spoiler is used to increase the dose to the superficial tissues. This paper finds the property of the distance between beam spoiler and patient. Set-up conditions are 6 MV-Xray, 300 MU, SAD = 400 cm, field size = 40 x 40 cm 2 . The parallel plate chamber located in surface, midpoint and exit of solid water phantom. The surface dose is measured while the distance between beam spoiler and patient is altered. Because it should be found proper distance. The solid water phantom is fixer and beam spoiler is moving. Central dose of phantom is 10.7 cGy and exit dose is 6.7 cGy. In case of distance of 50 cm to 60 cm between beam spoiler and solid water phantom, incidence dose is 14.58-14.92 cGy. Therefore, The surface dose was measured 99.4-101% with got near most to the prescription dose. In clinical case, distance between beam spoiler and patient affect surface dose. If once 50-60 cm of distance between beam spoiler and patient, surface dose of patient got near prescription dose. It would be taken distance between beam spoiler and patient into account in clinical therapy.

  4. Estimation of the dose distribution within, and total dose to, the body of an acutely overexposed person

    International Nuclear Information System (INIS)

    Beer, G.P. de; Feather, J.I.; Oude, A. de; Language, A.E.

    1981-01-01

    In a case of accidental overexposure of a person, it is important to obtain a reliable value of the whole body dose as well as of the dose distribution within the body. Any follow-up treatment based only on the clinical effects as and when they appear, may result in insufficient or even erroneous therapy. In this respect knowledge of total dose and its distribution within the body may be a valuable aid in deciding on the follow-up treatment, taking into account the latent nature of the clinical effects. The calculated whole body dose and its distribution within the body of a person overexposed to a 192 Ir radiography source, are compared to experimentally determined values. In both cases the calculated values prove to be of sufficient accuracy to serve as an aid in decisions on the follow-up treatment. (author)

  5. Low-dose-rate total lymphoid irradiation: a new method of rapid immunosuppression

    International Nuclear Information System (INIS)

    Blum, J.E.; de Silva, S.M.; Rachman, D.B.; Order, S.E.

    1988-01-01

    Total Lymphoid Irradiation (TLI) has been successful in inducing immunosuppression in experimental and clinical applications. However, both the experimental and clinical utility of TLI are hampered by the prolonged treatment courses required (23 days in rats and 30-60 days in humans). Low-dose-rate TLI has the potential of reducing overall treatment time while achieving comparable immunosuppression. This study examines the immunosuppressive activity and treatment toxicity of conventional-dose-rate (23 days) vs low-dose-rate (2-7 days) TLI. Seven groups of Lewis rats were given TLI with 60Co. One group was treated at conventional-dose-rates (80-110 cGy/min) and received 3400 cGy in 17 fractions over 23 days. Six groups were treated at low-dose-rate (7 cGy/min) and received total doses of 800, 1200, 1800, 2400, 3000, and 3400 cGy over 2-7 days. Rats treated at conventional-dose-rates over 23 days and at low-dose-rate over 2-7 days tolerated radiation with minimal toxicity. The level of immunosuppression was tested using allogeneic (Brown-Norway) skin graft survival. Control animals retained allogeneic skin grafts for a mean of 14 days (range 8-21 days). Conventional-dose-rate treated animals (3400 cGy in 23 days) kept their grafts 60 days (range 50-66 days) (p less than .001). Low-dose-rate treated rats (800 to 3400 cGy total dose over 2-7 days) also had prolongation of allogeneic graft survival times following TLI with a dose-response curve established. The graft survival time for the 3400 cGy low-dose-rate group (66 days, range 52-78 days) was not significantly different from the 3400 cGy conventional-dose-rate group (p less than 0.10). When the total dose given was equivalent, low-dose-rate TLI demonstrated an advantage of reduced overall treatment time compared to conventional-dose-rate TLI (7 days vs. 23 days) with no increase in toxicity

  6. SU-E-I-91: Reproducibility in Prescribed Dose in AEC CT Scans Due to Table Height, Patient Size, and Localizer Acquisition Order

    International Nuclear Information System (INIS)

    Winslow, J; Hurwitz, L; Christianson, O; Samei, E

    2014-01-01

    Purpose: In CT scanners, the automatic exposure control (AEC) tube current prescription depends on the acquired prescan localizer image(s). The purpose of this study was to quantify the effect that table height, patient size, and localizer acquisition order may have on the reproducibility in prescribed dose. Methods: Three phantoms were used for this study: the Mercury Phantom (comprises three tapered and four uniform regions of polyethylene 16, 23, 30, and 37 cm in diameter), acrylic sheets, and an adult anthropomorphic phantom. Phantoms were positioned per clinical protocol by our chief CT technologist or broader symmetry. Using a GE Discovery CT750HD scanner, a lateral (LAT) and posterior-anterior (PA) localizer was acquired for each phantom at different table heights. AEC scan acquisitions were prescribed for each combination of phantom, localizer orientation, and table height; the displayed volume CTDI was recorded for each. Results were analyzed versus table height. Results: For the two largest Mercury Phantom section scans based on the PA localizer, the percent change in volume CTDI from ideal were at least 20% lower and 35% greater for table heights 4 cm above and 4 cm below proper centering, respectively. For scans based on the LAT localizer, the percent change in volume CTDI from ideal were no greater than 12% different for 4 cm differences in table height. The properly centered PA and LAT localizer-based volume CTDI values were within 13% of each other. Conclusion: Since uncertainty in vertical patient positioning is inherently greater than lateral positioning and because the variability in dose exceeds any dose penalties incurred, the LAT localizer should be used to precisely and reproducibly deliver the intended amount of radiation prescribed by CT protocols. CT protocols can be adjusted to minimize the expected change in average patient dose

  7. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    International Nuclear Information System (INIS)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor; Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette

    2017-01-01

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D mean ), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D mean was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m 2 , with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D mean exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [de

  8. Xerostomia after radiotherapy. What matters - mean total dose or dose to each parotid gland?

    International Nuclear Information System (INIS)

    Tribius, S.; Sommer, J.; Prosch, C.; Bajrovic, A.; Kruell, A.; Petersen, C.; Muenscher, A.; Blessmann, M.; Todorovic, M.; Tennstedt, P.

    2013-01-01

    Purpose: Xerostomia is a debilitating side effect of radiotherapy in patients with head and neck cancer. We undertook a prospective study of the effect on xerostomia and outcomes of sparing one or both parotid glands during radiotherapy for patients with squamous cell carcinoma of the head and neck. Methods and materials: Patients with locally advanced squamous cell carcinoma of the head and neck received definitive (70 Gy in 2 Gy fractions) or adjuvant (60-66 Gy in 2 Gy fractions) curative-intent radiotherapy using helical tomotherapy with concurrent chemotherapy if appropriate. Group A received < 26 Gy to the left and right parotids and group B received < 26 Gy to either parotid. Results: The study included 126 patients; 114 (55 in group A and 59 in group B) had follow-up data. There were no statistically significant differences between groups in disease stage. Xerostomia was significantly reduced in group A vs. group B (p = 0.0381). Patients in group A also had significantly less dysphagia. Relapse-free and overall survival were not compromised in group A: 2-year relapse-free survival was 86% vs. 72% in group B (p = 0.361); 2-year overall survival was 88% and 76%, respectively (p = 0.251). Conclusion: This analysis suggests that reducing radiotherapy doses to both parotid glands to < 26 Gy can reduce xerostomia and dysphagia significantly without compromising survival. Sparing both parotids while maintaining target volume coverage and clinical outcome should be the treatment goal and reporting radiotherapy doses delivered to the individual parotids should be standard practice. (orig.)

  9. Xerostomia after radiotherapy. What matters - mean total dose or dose to each parotid gland?

    Energy Technology Data Exchange (ETDEWEB)

    Tribius, S.; Sommer, J.; Prosch, C.; Bajrovic, A.; Kruell, A.; Petersen, C. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Radiation Oncology; Muenscher, A. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Otorhinolaryngology and Head and Neck Surgery; Blessmann, M. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Oral and Maxillofacial Surgery; Todorovic, M. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Medical Physics; Tennstedt, P. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Martini-Clinic, Prostate Cancer Center

    2013-03-15

    Purpose: Xerostomia is a debilitating side effect of radiotherapy in patients with head and neck cancer. We undertook a prospective study of the effect on xerostomia and outcomes of sparing one or both parotid glands during radiotherapy for patients with squamous cell carcinoma of the head and neck. Methods and materials: Patients with locally advanced squamous cell carcinoma of the head and neck received definitive (70 Gy in 2 Gy fractions) or adjuvant (60-66 Gy in 2 Gy fractions) curative-intent radiotherapy using helical tomotherapy with concurrent chemotherapy if appropriate. Group A received < 26 Gy to the left and right parotids and group B received < 26 Gy to either parotid. Results: The study included 126 patients; 114 (55 in group A and 59 in group B) had follow-up data. There were no statistically significant differences between groups in disease stage. Xerostomia was significantly reduced in group A vs. group B (p = 0.0381). Patients in group A also had significantly less dysphagia. Relapse-free and overall survival were not compromised in group A: 2-year relapse-free survival was 86% vs. 72% in group B (p = 0.361); 2-year overall survival was 88% and 76%, respectively (p = 0.251). Conclusion: This analysis suggests that reducing radiotherapy doses to both parotid glands to < 26 Gy can reduce xerostomia and dysphagia significantly without compromising survival. Sparing both parotids while maintaining target volume coverage and clinical outcome should be the treatment goal and reporting radiotherapy doses delivered to the individual parotids should be standard practice. (orig.)

  10. Estimation of the total absorbed dose by quartz in retrospective conditions

    International Nuclear Information System (INIS)

    Correcher, V.; Delgado, A.

    2003-01-01

    The estimation of the total absorbed dose is of great interest in areas affected by a radiological accident when no conventional dosimetric systems are available. This paper reports about the usual methodology employed in dose reconstruction from the thermoluminescence (TL) properties of natural quartz, extracted from selected ceramic materials (12 bricks) picked up in the Chernobyl area. It has been possible to evaluate doses under 50mGy after more than 11 years later since the radiological accident happened. The main advance of this fact is the reduction of the commonly accepted limit dose estimation more than 20 times employing luminescence methods. (Author) 11 refs

  11. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  12. Single event effects and total ionizing dose effects of typical VDMOSFET devices

    International Nuclear Information System (INIS)

    Lou Jianshe; Cai Nan; Liu Jiaxin; Wu Qinzhi; Wang Jia

    2012-01-01

    In this work, single event effects and total ionizing dose effects of typical VDMOSFET irradiated by 60 Co γ-rays and 252 Cf source were studied. The single event burnout and single event gate rupture (SEB/SEGR) effects were investigated, and the relationship between drain-source breakdown voltage and ionizing dose was obtained. The results showed that the VDMOSFET devices were sensitive to SEB and SEGR, and measures to improve their resistance to SEB and SEGR should be considered seriously for their space applications. The drain-source breakdown voltage was sensitive to total ionizing dose effects as the threshold voltage. In assessing the devices' resistance to the total ionizing dose effects, both the threshold voltage and the drain-source breakdown voltage should be taken into account. (authors)

  13. Serum protein concentration in low-dose total body irradiation of normal and malnourished rats

    International Nuclear Information System (INIS)

    Viana, W.C.M.; Lambertz, D.; Borges, E.S.; Neto, A.M.O.; Lambertz, K.M.F.T.; Amaral, A.

    2016-01-01

    Among the radiotherapeutics' modalities, total body irradiation (TBI) is used as treatment for certain hematological, oncological and immunological diseases. The aim of this study was to evaluate the long-term effects of low-dose TBI on plasma concentration of total protein and albumin using prematurely and undernourished rats as animal model. For this, four groups with 9 animals each were formed: Normal nourished (N); Malnourished (M); Irradiated Normal nourished (IN); Irradiated Malnourished (IM). At the age of 28 days, rats of the IN and IM groups underwent total body gamma irradiation with a source of cobalt-60. Total protein and Albumin in the blood serum was quantified by colorimetry. This research indicates that procedures involving low-dose total body irradiation in children have repercussions in the reduction in body-mass as well as in the plasma levels of total protein and albumin. Our findings reinforce the periodic monitoring of total serum protein and albumin levels as an important tool in long-term follow-up of pediatric patients in treatments associated to total body irradiation. - Highlights: • Low-dose total body irradiation (TBI) in children have repercussions in their body-mass. • Long-term total protein and albumin levels are affected by TBI. • The monitoring of total protein and albumin levels are useful in the follow-up of TBI pediatric patients.

  14. Dose characteristics of total-skin electron-beam irradiation with six-dual electron fields

    International Nuclear Information System (INIS)

    Choi, Tae Jin; Kim, Jin Hee; Kim, Ok Bae

    1998-01-01

    To obtain the uniform dose at limited depth to entire surface of the body, the dose characteristics of degraded electron beam of the large target-skin distance and the dose distribution of the six-dual electron fields were investigated. The experimental dose distributions included the depth dose curve, spatial dose and attenuated electron beam were determined with 300 cm of Target-Skin Distance (TSD) and full collimator size (35x35 cm 2 on TSD 100 cm) in 4 MeV electron beam energy. Actual collimated field size of 105 cmx105 cm at the distance of 300 cm could include entire hemibody. A patient was standing on step board with hands up and holding the pole to stabilize his/her positions for the six-dual fields technique. As a scatter-degrader, 0.5 cm of acrylic plate was inserted at 20 cm from the body surface on the electron beam path to induce ray scattering and to increase the skin dose. The Full Width at Half Maximum(FWHM) of dose profile was 130 cm in large field of 105x105 cm 2 . The width of 100±10% of the resultant dose from two adjacent fields which were separated at 25 cm from field edge for obtaining the dose uniformity was extended to 186 cm. The depth of maximum dose lies at 5 mm and the 80% depth dose lies between 7 and 8 mm for the degraded electron beam by using the 0.5 cm thickness of acrylic absorber. Total skin electron beam irradiation (TSEBI) was carried out using the six dual fields has been developed at Stanford University. The dose distribution in TSEBI showed relatively uniform around the flat region of skin except the protruding and deeply curvatured portion of the body, which showed excess of dose at the former and less dose at the latter. The percent depth dose, profile curves and superimposed dose distribution were investigated using the degraded using the degraded electron beam through the beam absorber. The dose distribution obtained by experiments of TSEBI showed within±10% difference excepts the protruding area of skin which needs a

  15. Creation of a long-term data record of total O3 - issues and challenges in prescribing the uncertainties

    Science.gov (United States)

    Haffner, D. P.; Bhartia, P. K.; Li, J. Y.

    2012-12-01

    With the launch of the BUV instrument on NASA's Nimbus-4 satellite in April 1970, ozone became one of the first atmospheric variables to be measured from space with high accuracy. By 1980, the quality of total column ozone measured from the TOMS instrument on the Nimbus-7 satellite had improved to the point that it started to be used to identify poorly calibrated instruments in the venerable Dobson ground-based network. Now we have a total ozone record spanning 42 years created by more than a dozen instruments. We will discuss the issues and challenges that we have faced in creating a consistent long-term record and in providing uncertainty estimates. This work is not yet finished. We are currently developing a new algorithm (Version 9) that will be used to reprocess the entire record. The main motivation for developing this algorithm is not so much to improve the quality of the data, which is quite high already, but to provide better estimates of uncertainties when errors are spatially and temporally correlated, and to develop better techniques to catch "Black Swan" events (BSE). These are events that occur infrequently but cause errors larger than expected by Gaussian probability distribution. For example, the eruption of El Chichón revealed that our ozone algorithm had unexpected sensitivity to volcanic SO2, and evidence of the ozone hole was initially interpreted as a problem with the TOMS instrument. We also provide mathematical operators that can be applied by sophisticated users to compute their own uncertainties for their particular applications. This is necessary because uncertainties change in complex ways when the data are smoothed or averaged. The modern data archival system should be designed to accommodate such operators and provide software for using them.

  16. Enhancement of Transistor-to-Transistor Variability Due to Total Dose Effects in 65-nm MOSFETs

    CERN Document Server

    Gerardin, S; Cornale, D; Ding, L; Mattiazzo, S; Paccagnella, A; Faccio, F; Michelis, S

    2015-01-01

    We studied device-to-device variations as a function of total dose in MOSFETs, using specially designed test structures and procedures aimed at maximizing matching between transistors. Degradation in nMOSFETs is less severe than in pMOSFETs and does not show any clear increase in sample-to-sample variability due to the exposure. At doses smaller than 1 Mrad( SiO2) variability in pMOSFETs is also practically unaffected, whereas at very high doses-in excess of tens of Mrad( SiO2)-variability in the on-current is enhanced in a way not correlated to pre-rad variability. The phenomenon is likely due to the impact of random dopant fluctuations on total ionizing dose effects.

  17. Relative effect of radiation dose rate on hemopoietic and nonhemopoietic lethality of total-body irradiation

    International Nuclear Information System (INIS)

    Peters, L.J.; McNeill, J.; Karolis, C.; Thames, H.D. Jr.; Travis, E.L.

    1986-01-01

    Experiments were undertaken to determine the influence of dose rate on the toxicity of total-body irrdiation (TBI) with and without syngeneic bone-marrow rescue in mice. The results showed a much greater dose-rate dependence for death from nonhemopoietic toxicity than from bone-marrow ablation, with the ratio of LD 50 's increasing from 1.73 at 25 cGy/min to 2.80 at 1 cGy/min. At the higher dose rates, dose-limiting nonhemopoietic toxicity resulted from late organ injury, affecting the lungs, kidneys, and liver. At 1 cGy/min the major dose-limiting nonhemopoietic toxicity was acute gastrointestinal injury. The implications of these results in the context of TBI in preparation for bone-marrow transplantation are discussed. 15 refs., 4 figs

  18. Safety aspects of preoperative high-dose glucocorticoid in primary total knee replacement

    DEFF Research Database (Denmark)

    Jørgensen, C C; Pitter, F T; Kehlet, H

    2017-01-01

    Background: Preoperative single high-dose glucocorticoid may have early outcome benefits in total hip arthroplasty (THA) and knee arthroplasty (TKA), but long-term safety aspects have not been evaluated. Methods: From October 2013, the departments reporting to the prospective Lundbeck Foundation....... Conclusions: In this detailed prospective cohort study, preoperative high-dose glucocorticoid administration was not associated with LOS >4 days, readmissions or infectious complications in TKA patients without contraindications....

  19. Total dose effects on ATLAS-SCT front-end electronics

    CERN Document Server

    Ullán, M; Dubbs, T; Grillo, A A; Spencer, E; Seiden, A; Spieler, H; Gilchriese, M G D; Lozano, M

    2002-01-01

    Low dose rate effects (LDRE) in bipolar technologies complicate the hardness assurance testing for high energy physics applications. The damage produced in the ICs in the real experiment can be underestimated if fast irradiations are carried out, while experiments done at the real dose rate are usually unpractical due to the still high total doses involved. In this work the sensitivity to LDRE of two bipolar technologies proposed for the ATLAS-SCT experiment at CERN is evaluated, finding one of them free of those effects. (12 refs).

  20. The total dose effects on the 1/f noise of deep submicron CMOS transistors

    International Nuclear Information System (INIS)

    Hu Rongbin; Wang Yuxin; Lu Wu

    2014-01-01

    Using 0.18 μm CMOS transistors, the total dose effects on the 1/f noise of deep-submicron CMOS transistors are studied for the first time in mainland China. From the experimental results and the theoretic analysis, we realize that total dose radiation causes a lot of trapped positive charges in STI (shallow trench isolation) SiO 2 layers, which induces a current leakage passage, increasing the 1/f noise power of CMOS transistors. In addition, we design some radiation-hardness structures on the CMOS transistors and the experimental results show that, until the total dose achieves 750 krad, the 1/f noise power of the radiation-hardness CMOS transistors remains unchanged, which proves our conclusion. (semiconductor devices)

  1. SU-E-T-92: Achieving Desirable Lung Doses in Total Body Irradiation Based On in Vivo Dosimetry and Custom Tissue Compensation

    International Nuclear Information System (INIS)

    Cui, G; Shiu, A; Zhou, S; Cui, J; Ballas, L

    2015-01-01

    Purpose: To achieve desirable lung doses in total body irradiation (TBI) based on in vivo dosimetry and custom tissue compensation. Methods: The 15 MV photon beam of a Varian TrueBeam STx linac was used for TBI. Patients were positioned in the lateral decubitus position for AP/PA treatment delivery. Dose was calculated using the midpoint of the separation distance across the patient’s umbilicus. Patients received 200 cGy twice daily for 3 days. The dose rate at the patient’s midplane was approximately 10 cGy/min. Cerrobend blocks with a 5-HVL thickness were used for the primary lung shielding. A custom styrofoam holder for rice-flour filled bags was created based on the lung block cutouts. This was used to provide further lung shielding based on in vivo dose measurements. Lucite plates and rice-flour bags were placed in the head, neck, chest, and lower extremity regions during the treatment to compensate for the beam off-axis output variations. Two patients were included in the study. Patients 1 and 2 received a craniospinal treatment (1080 cGy) and a mediastinum treatment (2520 cGy), respectively, before the TBI. During the TBI nanoDot dosimeters were placed on the patient skin in the forehead, neck, umbilicus, and lung regions for dose monitoring. The doses were readout immediately after the treatment. Based on the readings, fine tuning of the thickness of the rice-flour filled bags was exploited to achieve the desirable lung doses. Results: For both patients the mean lung doses, which took into consideration all treatments, were controlled within 900 +/−10% cGy, as desired. Doses to the forehead, neck, and umbilicus were achieved within +/−10% of the prescribed dose (1200 cGy). Conclusion: A reliable and robust method was developed to achieve desirable lung doses and uniform body dose in TBI based on in vivo dosimetry and custom tissue compensator

  2. SU-E-T-92: Achieving Desirable Lung Doses in Total Body Irradiation Based On in Vivo Dosimetry and Custom Tissue Compensation

    Energy Technology Data Exchange (ETDEWEB)

    Cui, G; Shiu, A; Zhou, S; Cui, J; Ballas, L [Univ Southern California, Los Angeles, CA (United States)

    2015-06-15

    Purpose: To achieve desirable lung doses in total body irradiation (TBI) based on in vivo dosimetry and custom tissue compensation. Methods: The 15 MV photon beam of a Varian TrueBeam STx linac was used for TBI. Patients were positioned in the lateral decubitus position for AP/PA treatment delivery. Dose was calculated using the midpoint of the separation distance across the patient’s umbilicus. Patients received 200 cGy twice daily for 3 days. The dose rate at the patient’s midplane was approximately 10 cGy/min. Cerrobend blocks with a 5-HVL thickness were used for the primary lung shielding. A custom styrofoam holder for rice-flour filled bags was created based on the lung block cutouts. This was used to provide further lung shielding based on in vivo dose measurements. Lucite plates and rice-flour bags were placed in the head, neck, chest, and lower extremity regions during the treatment to compensate for the beam off-axis output variations. Two patients were included in the study. Patients 1 and 2 received a craniospinal treatment (1080 cGy) and a mediastinum treatment (2520 cGy), respectively, before the TBI. During the TBI nanoDot dosimeters were placed on the patient skin in the forehead, neck, umbilicus, and lung regions for dose monitoring. The doses were readout immediately after the treatment. Based on the readings, fine tuning of the thickness of the rice-flour filled bags was exploited to achieve the desirable lung doses. Results: For both patients the mean lung doses, which took into consideration all treatments, were controlled within 900 +/−10% cGy, as desired. Doses to the forehead, neck, and umbilicus were achieved within +/−10% of the prescribed dose (1200 cGy). Conclusion: A reliable and robust method was developed to achieve desirable lung doses and uniform body dose in TBI based on in vivo dosimetry and custom tissue compensator.

  3. Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film

    International Nuclear Information System (INIS)

    Gamble, Lisa M; Farrell, Thomas J; Jones, Glenn W; Hayward, Joseph E

    2003-01-01

    Total skin electron (TSE) radiotherapy is routinely used to treat cutaneous T-cell lymphomas and can be implemented using a modified Stanford technique. In our centre, the composite depth dose for this technique is achieved by a combination of two patient positions per day over a three-day cycle, and two gantry angles per patient position. Due to patient morphology, underdosed regions typically occur and have historically been measured using multiple thermoluminescent dosimeters (TLDs). We show that radiochromic film can be used as a two-dimensional relative dosimeter to measure the percent depth dose in TSE radiotherapy. Composite depth dose curves were measured in a cylindrical, polystyrene phantom and compared with TLD data. Both multiple films (1 film per day) and a single film were used in order to reproduce a realistic clinical scenario. First, three individual films were used to measure the depth dose, one per treatment day, and then compared with TLD data; this comparison showed a reasonable agreement. Secondly, a single film was used to measure the dose delivered over three daily treatments and then compared with TLD data; this comparison showed good agreement throughout the depth dose, which includes doses well below 1 Gy. It will be shown that one piece of radiochromic film is sufficient to measure the composite percent depth dose for a TSE beam, hence making radiochromic film a suitable candidate for monitoring underdosed patient regions

  4. An experimental study on total dose effects in SRAM-based FPGAs

    International Nuclear Information System (INIS)

    Yao Zhibin; He Baoping; Zhang Fengqi; Guo Hongxia; Luo Yinhong; Wang Yuanming; Zhang Keying

    2009-01-01

    In order to study testing methods and find sensitive parameters in total dose effects on SRAM-based FPGA, XC2S100 chips were irradiated by 60 Co γ-rays and tested with two test circuit designs. By analyzing the experimental results, the test flow of configuration RAM and bock RAM was given, and the most sensitive parameter was obtained. The results will be a solid foundation for establishing test specification and evaluation methods of total dose effects on SRAM-based FPGAs. (authors)

  5. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A.

    1990-01-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy

  6. Enchanced total dose damage in junction field effect transistors and related linear integrated circuits

    International Nuclear Information System (INIS)

    Flament, O.; Autran, J.L.; Roche, P.; Leray, J.L.; Musseau, O.

    1996-01-01

    Enhanced total dose damage of Junction Field-effect Transistors (JFETs) due to low dose rate and/or elevated temperature has been investigated for elementary p-channel structures fabricated on bulk and SOI substrates as well as for related linear integrated circuits. All these devices were fabricated with conventional junction isolation (field oxide). Large increases in damage have been revealed by performing high temperature and/or low dose rate irradiations. These results are consistent with previous studies concerning bipolar field oxides under low-field conditions. They suggest that the transport of radiation-induced holes through the oxide is the underlying mechanism. Such an enhanced degradation must be taken into account for low dose rate effects on linear integrated circuits

  7. Antiepileptic drug prescribing before, during and after pregnancy

    DEFF Research Database (Denmark)

    Charlton, Rachel; Garne, Ester; Wang, Hao

    2015-01-01

    and after pregnancy were identified in each of the databases. AED prescribing patterns were analysed, and the choice of AEDs and co-prescribing of folic acid were evaluated. Results In total, 978 957 women with 1 248 713 deliveries were identified. In all regions, AED prescribing declined during pregnancy...... co-prescribed with high-dose folic acid: ranging from 1.0% (CI950.3–1.8%) in Emilia Romagna to 33.5% (CI9528.7–38.4%) in Wales. Conclusion The country's differences in prescribing patterns may suggest different use, knowledge or interpretation of the scientific evidence base. The low co......-prescribing of folic acid indicates that more needs to be done to better inform clinicians and women of childbearing age taking AEDs about the need to offer and receive complete preconception care....

  8. Total dose hardness of a commercial SiGe BiCMOS technology

    International Nuclear Information System (INIS)

    Van Vonno, N.; Lucas, R.; Thornberry, D.

    1999-01-01

    Over the past decade SiGe HBT technology has progress from the laboratory to actual commercial applications. When integrated into a BiMOS process, this technology has applications in low-cost space systems. In this paper, we report results of total dose testing of a SiGe/CMOS process accessible through a commercial foundry. (authors)

  9. Worst-Case Bias During Total Dose Irradiation of SOI Transistors

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Colladant, T.; Paillet, P.; Leray, J.-L; Musseau, O.; Schwank, James R.; Shaneyfelt, Marty R.; Pelloie, J.L.; Du Port de Poncharra, J.

    2000-01-01

    The worst case bias during total dose irradiation of partially depleted SOI transistors (from SNL and from CEA/LETI) is correlated to the device architecture. Experiments and simulations are used to analyze SOI back transistor threshold voltage shift and charge trapping in the buried oxide

  10. Recent Total Ionizing Dose Results and Displacement Damage Results for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    Cochran, Donna J.; Buchner, Stephen P.; Irwin, Tim L.; LaBel, Kenneth A.; Marshall, Cheryl J.; Reed, Robert A.; Sanders, Anthony B.; Hawkins, Donald K.; Flanigan, Ryan J.; Cox, Stephen R.

    2005-01-01

    We present data on the vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage. Devices tested include optoelectronics, digital, analog, linear bipolar devices, hybrid devices, Analog-to- Digital Converters (ADCs), and Digital-to-Analog Converters (DACs), among others. T

  11. Inclusion of Radiation Environment Variability in Total Dose Hardness Assurance Methodology

    Science.gov (United States)

    Xapsos, M. A.; Stauffer, C.; Phan, A.; McClure, S. S.; Ladbury, R. L.; Pellish, J. A.; Campola, M. J.; LaBel, K. A.

    2016-01-01

    Variability of the space radiation environment is investigated with regard to parts categorization for total dose hardness assurance methods. It is shown that it can have a significant impact. A modified approach is developed that uses current environment models more consistently and replaces the radiation design margin concept with one of failure probability during a mission.

  12. The influence of x-ray energy on lung dose uniformity in total-body irradiation

    International Nuclear Information System (INIS)

    Ekstrand, Kenneth; Greven, Kathryn; Wu Qingrong

    1997-01-01

    Purpose: In this study we examine the influence of x-ray energy on the uniformity of the dose within the lung in total-body irradiation treatments in which partial transmission blocks are used to control the lung dose. Methods and Materials: A solid water phantom with a cork insert to simulate a lung was irradiated by x-rays with energies of either 6, 10, or 18 MV. The source to phantom distance was 3.9 meters. The cork insert was either 10 cm wide or 6 cm wide. Partial transmission blocks with transmission factors of 50% were placed anterior to the cork insert. The blocks were either 8 or 4 cm in width. Kodak XV-2 film was placed in the midline of the phantom to record the dose. Midplane dose profiles were measured with a densitometer. Results: For the 10 cm wide cork insert the uniformity of the dose over 80% of the block width varied from 6.6% for the 6 MV x-rays to 12.2% for the 18 MV x-rays. For the 6 cm wide cork insert the uniformity was comparable for all three x-ray energies, but for 18 MV the central dose increased by 9.4% compared to the 10 cm wide insert. Conclusion: Many factors must be considered in optimizing the dose for total-body irradiation. This study suggests that for AP/PA techniques lung dose uniformity is superior with 6 MV irradiation. The blanket recommendation that the highest x-ray energy be used in TBI is not valid for all situations

  13. SU-E-T-357: Electronic Compensation Technique to Deliver Total Body Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [State University of New York at Buffalo, Buffalo, NY (United States); Wang, I; Podgorsak, M [State University of New York at Buffalo, Buffalo, NY (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient’s immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has conventionally been used to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Methods: Treatment plans utilizing electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two, specifically weighted, pair of opposed fields. One pair of open, large fields (collimator=45°), to encompass the patient’s entire anatomy, and one pair of smaller fields (collimator=0°) focused only on the thicker midsection of the patient. The optimal fluence for each one of the smaller fields was calculated at a patient specific penetration depth. Irregular surface compensators provide a more uniform dose distribution within the smaller opposed fields. Results: Dose-volume histograms (DVH) were calculated for the evaluating the electronic compensation technique. In one case, the maximum body doses calculated from the DVH were reduced from the non-compensated 195.8% to 165.3% in the electronically compensated plans, indicating a more uniform dose with the region of electronic compensation. The mean body doses calculated from the DVH were also reduced from the non-compensated 120.6% to 112.7% in the electronically compensated plans, indicating a more accurate delivery of the prescription dose. All calculated monitor units were well within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not substantially increase the beam on time while it can significantly reduce the compensator

  14. Rationalising prescribing

    DEFF Research Database (Denmark)

    Wadmann, Sarah; Bang, Lia Evi

    2015-01-01

    Initiatives in the name of 'rational pharmacotherapy' have been launched to alter what is seen as 'inappropriate' prescribing practices of physicians. Based on observations and interviews with 20 general practitioners (GPs) in 2009-2011, we explored how attempts to rationalise prescribing interac...

  15. Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure.

    Science.gov (United States)

    Camarata, Andrew S; Switchenko, Jeffrey M; Demidenko, Eugene; Flood, Ann B; Swartz, Harold M; Ali, Arif N

    2016-04-01

    Current radiation disaster manuals list the time-to-emesis (TE) as the key triage indicator of radiation dose. The data used to support TE recommendations were derived primarily from nearly instantaneous, high dose-rate exposures as part of variable condition accident databases. To date, there has not been a systematic differentiation between triage dose estimates associated with high and low dose rate (LDR) exposures, even though it is likely that after a nuclear detonation or radiologic disaster, many surviving casualties would have received a significant portion of their total exposure from fallout (LDR exposure) rather than from the initial nuclear detonation or criticality event (high dose rate exposure). This commentary discusses the issues surrounding the use of emesis as a screening diagnostic for radiation dose after LDR exposure. As part of this discussion, previously published clinical data on emesis after LDR total body irradiation (TBI) is statistically re-analyzed as an illustration of the complexity of the issue and confounding factors. This previously published data includes 107 patients who underwent TBI up to 10.5 Gy in a single fraction delivered over several hours at 0.02 to 0.04 Gy min. Estimates based on these data for the sensitivity of emesis as a screening diagnostic for the low dose rate radiation exposure range from 57.1% to 76.6%, and the estimates for specificity range from 87.5% to 99.4%. Though the original data contain multiple confounding factors, the evidence regarding sensitivity suggests that emesis appears to be quite poor as a medical screening diagnostic for LDR exposures.

  16. Time- and dose-dependent effects of total-body ionizing radiation on muscle stem cells

    Science.gov (United States)

    Masuda, Shinya; Hisamatsu, Tsubasa; Seko, Daiki; Urata, Yoshishige; Goto, Shinji; Li, Tao-Sheng; Ono, Yusuke

    2015-01-01

    Exposure to high levels of genotoxic stress, such as high-dose ionizing radiation, increases both cancer and noncancer risks. However, it remains debatable whether low-dose ionizing radiation reduces cellular function, or rather induces hormetic health benefits. Here, we investigated the effects of total-body γ-ray radiation on muscle stem cells, called satellite cells. Adult C57BL/6 mice were exposed to γ-radiation at low- to high-dose rates (low, 2 or 10 mGy/day; moderate, 50 mGy/day; high, 250 mGy/day) for 30 days. No hormetic responses in proliferation, differentiation, or self-renewal of satellite cells were observed in low-dose radiation-exposed mice at the acute phase. However, at the chronic phase, population expansion of satellite cell-derived progeny was slightly decreased in mice exposed to low-dose radiation. Taken together, low-dose ionizing irradiation may suppress satellite cell function, rather than induce hormetic health benefits, in skeletal muscle in adult mice. PMID:25869487

  17. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiotherapy and Radiooncology, Muenster (Germany); Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette [University Hospital of Muenster, Department of Phoniatrics and Pediatric Audiology, Muenster (Germany)

    2017-11-15

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D{sub mean}), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D{sub mean} was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m{sup 2}, with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D{sub mean} exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [German] Analyse von Inzidenz und Schweregrad einer sensorineuralen Schwerhoerigkeit (''sensorineural hearing loss'', SNHL) infolge der Wirkung unterschiedlicher Bestrahlungstechniken, Fraktionierungen, mittlerer

  18. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  19. Total dose hardening of buried insulator in implanted silicon-on-insulator structures

    International Nuclear Information System (INIS)

    Mao, B.Y.; Chen, C.E.; Pollack, G.; Hughes, H.L.; Davis, G.E.

    1987-01-01

    Total dose characteristics of the buried insulator in implanted silicon-on-insulator (SOI) substrates have been studied using MOS transistors. The threshold voltage shift of the parasitic back channel transistor, which is controlled by charge trapping in the buried insulator, is reduced by lowering the oxygen dose as well as by an additional nitrogen implant, without degrading the front channel transistor characteristics. The improvements in the radiation characteristics of the buried insulator are attributed to the decrease in the buried oxide thickness or to the presence of the interfacial oxynitride layer formed by the oxygen and nitrogen implants

  20. Low-dose total skin electron beam therapy for cutaneous lymphoma. Minimal risk of acute toxicities

    Energy Technology Data Exchange (ETDEWEB)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiation Oncology, Muenster (Germany)

    2017-12-15

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T-cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P < 0.001). A lower grade 3 AE rate was also observed in patients who had received the low-dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses. (orig.) [German] Eine niedrigdosierte Ganzhautelektronenbestrahlung (TSEBT) wird vermehrt zur effektiven palliativen Behandlung von Patienten mit primaer kutanen T-Zell-Lymphomen (pCTCL) eingesetzt. In dieser Studie vergleichen wir die Toxizitaetsprofile verschiedener Dosiskonzepte. Untersucht wurden 60 zwischen 2000 und 2016 am Universitaetsklinikum Muenster mittels TSEBT

  1. Measurement with total scatter calibrate factor at different depths in the calculation of prescription dose

    International Nuclear Information System (INIS)

    Li Lijun; Zhu Haijun; Zhang Xinzhong; Li Feizhou; Song Hongyu

    2004-01-01

    Objective: To evaluate the method of measurement of total scatter calibrate factor (Sc, p). Methods: To measure the Sc, p at different depths on central axis of 6MV, 15MV photon beams through different ways. Results: It was found that the measured data of Sc, p changed with the different depths to a range of 1% - 7%. Using the direct method, the Sc, p measured depth should be the same as the depth in dose normalization point of the prescription dose. If the Sc, p (fsz, d) was measured at the other depths, it could be obtained indirectly by the calculation formula. Conclusions: The Sc, p in the prescription dose can be obtained either by the direct measure method or the indirect calculation formula. But emphasis should be laid on the proper measure depth. (authors)

  2. Statistical analysis of dose heterogeneity in circulating blood: Implications for sequential methods of total body irradiation

    International Nuclear Information System (INIS)

    Molloy, Janelle A.

    2010-01-01

    Purpose: Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these ''sequential'' techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Methods: Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. Results: The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than ±10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times

  3. Statistical analysis of dose heterogeneity in circulating blood: implications for sequential methods of total body irradiation.

    Science.gov (United States)

    Molloy, Janelle A

    2010-11-01

    Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these "sequential" techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than +/- 10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times. However, the EUD was

  4. The Role of Electron Transport and Trapping in MOS Total-Dose Modeling

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Winokur, P.S.; Riewe, L.C.; Flament, O.; Paillet, P.; Leray, J.L.

    1999-01-01

    Radiation-induced hole and electron transport and trapping are fundamental to MOS total-dose models. Here we separate the effects of electron-hole annihilation and electron trapping on the neutralization of radiation-induced charge during switched-bias irradiation for hard and soft oxides, via combined thermally stimulated current (TSC) and capacitance-voltage measurements. We also show that present total-dose models cannot account for the thermal stability of deeply trapped electrons near the Si/SiO 2 interface, or the inability of electrons in deep or shallow traps to contribute to TSC at positive bias following (1) room-temperature, (2) high-temperature, or (3) switched-bias irradiation. These results require revisions of modeling parameters and boundary conditions for hole and electron transport in SiO 2 . The nature of deep and shallow electron traps in the near-interfacial SiO 2 is discussed

  5. Revisiting Low-Dose Total Skin Electron Beam Therapy in Mycosis Fungoides

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Cameron, E-mail: cameronh@stanford.edu [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Young, James; Navi, Daniel [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Riaz, Nadeem [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States); Lingala, Bharathi; Kim, Youn [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Hoppe, Richard [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States)

    2011-11-15

    Purpose: Total skin electron beam therapy (TSEBT) is a highly effective treatment for mycosis fungoides (MF). The standard course consists of 30 to 36 Gy delivered over an 8- to 10-week period. This regimen is time intensive and associated with significant treatment-related toxicities including erythema, desquamation, anhydrosis, alopecia, and xerosis. The aim of this study was to identify a lower dose alternative while retaining a favorable efficacy profile. Methods and Materials: One hundred two MF patients were identified who had been treated with an initial course of low-dose TSEBT (5-<30 Gy) between 1958 and 1995. Patients had a T stage classification of T2 (generalized patch/plaque, n = 51), T3 (tumor, n = 29), and T4 (erythrodermic, n = 22). Those with extracutaneous disease were excluded. Results: Overall response (OR) rates (>50% improvement) were 90% among patients with T2 to T4 disease receiving 5 to <10 Gy (n = 19). In comparison, OR rates between the 10 to <20 Gy and 20 to <30 Gy subgroups were 98% and 97%, respectively. There was no significant difference in median progression free survival (PFS) in T2 and T3 patients when stratified by dose group, and PFS in each was comparable to that of the standard dose. Conclusions: OR rates associated with low-dose TSEBT in the ranges of 10 to <20 Gy and 20 to <30 Gy are comparable to that of the standard dose ({>=} 30 Gy). Efficacy measures including OS, PFS, and RFS are also favorable. Given that the efficacy profile is similar between 10 and <20 Gy and 20 and <30 Gy, the utility of TSEBT within the lower dose range of 10 to <20 Gy merits further investigation, especially in the context of combined modality treatment.

  6. Total dose induced latch in short channel NMOS/SOI transistors

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Quoizola, S.; Musseau, O.; Flament, O.; Leray, J.L.; Pelloie, J.L.; Raynaud, C.; Faynot, O.

    1998-01-01

    A latch effect induced by total dose irradiation is observed in short channel SOI transistors. This effect appears on NMOS transistors with either a fully or a partially depleted structure. It is characterized by a hysteresis behavior of the Id-Vg characteristics at high drain bias for a given critical dose. Above this dose, the authors still observe a limited leakage current at low drain bias (0.1 V), but a high conduction current at high drain bias (2 V) as the transistor should be in the off-state. The critical dose above which the latch appears strongly depends on gate length, transistor structure (fully or partially depleted), buried oxide thickness and supply voltage. Two-dimensional (2D) numerical simulations indicate that the parasitic condition is due to the latch of the back gate transistor triggered by charge trapping in the buried oxide. To avoid the latch induced by the floating body effect, different techniques can be used: doping engineering, body contacts, etc. The study of the main parameters influencing the latch (gate length, supply voltage) shows that the scaling of technologies does not necessarily imply an increased latch sensitivity. Some technological parameters like the buried oxide hardness and thickness can be used to avoid latch, even at high cumulated dose, on highly integrated SOI technologies

  7. Test methods of total dose effects in very large scale integrated circuits

    International Nuclear Information System (INIS)

    He Chaohui; Geng Bin; He Baoping; Yao Yujuan; Li Yonghong; Peng Honglun; Lin Dongsheng; Zhou Hui; Chen Yusheng

    2004-01-01

    A kind of test method of total dose effects (TDE) is presented for very large scale integrated circuits (VLSI). The consumption current of devices is measured while function parameters of devices (or circuits) are measured. Then the relation between data errors and consumption current can be analyzed and mechanism of TDE in VLSI can be proposed. Experimental results of 60 Co γ TDEs are given for SRAMs, EEPROMs, FLASH ROMs and a kind of CPU

  8. Total skin electron irradiation: evaluation of dose uniformity throughout the skin surface

    International Nuclear Information System (INIS)

    Anacak, Yavuz; Arican, Zumre; Bar-Deroma, Raquel; Tamir, Ada; Kuten, Abraham

    2003-01-01

    In this study, in vivo dosimetic data of 67 total skin electron irradiation (TSEI) treatments were analyzed. Thermoluminescent dosimetry (TLD) measurements were made at 10 different body points for every patient. The results demonstrated that the dose inhomogeneity throughout the skin surface is around 15%. The homogeneity was better at the trunk than at the extratrunk points, and was worse when a degrader was used. There was minimal improvement of homogeneity in subsequent days of treatment

  9. Lack of asthma and rhinitis control in general practitioner-managed patients prescribed fixed-dose combination therapy in Australia.

    Science.gov (United States)

    Bosnic-Anticevich, Sinthia; Kritikos, Vicky; Carter, Victoria; Yan, Kwok Yin; Armour, Carol; Ryan, Dermot; Price, David

    2018-06-01

    The first aim of the study (i) assess the current asthma status of general-practitioner-managed patients receiving regular fixed-dose combination inhaled corticosteroid and long-acting beta 2 agonist (FDC ICS/LABA) therapy and (ii) explore patients' perceptions of asthma control and attitudes/behaviors regarding preventer inhaler use. A cross-sectional observational study of Australian adults with a current physician diagnosis of asthma receiving ≥2 prescriptions of FDC ICS/LABA therapy in the previous year, who were recruited through general practice to receive a structured in-depth asthma review between May 2012 and January 2014. Descriptive statistics and Chi-Square tests for independence were used for associations across asthma control levels. Only 11.5% of the patients had controlled asthma based on guideline-defined criteria. Contrarily, 66.5% of the patients considered their asthma to be well controlled. Incidence of acute asthma exacerbations in the previous year was 26.5% and 45.6% of the patients were without a diagnosis of rhinitis. Asthma medication use and inhaler technique were sub-optimal; only 41.0% of the preventer users reported everyday use. The side effects of medication were common and more frequently reported among uncontrolled and partially controlled patients. The study revealed the extent to which asthma management needs to be improved in this patient cohort and the numerous unmet needs regarding the current state of asthma care. Not only there is a need for continuous education of patients, but also education of health care practitioners to better understand the way in which patient's perceptions impact on asthma management practices, incorporating these findings into clinical decision making.

  10. The Sandia total-dose estimator: SANDOSE description and user guide

    International Nuclear Information System (INIS)

    Turner, C.D.

    1995-02-01

    The SANdia total-DOSe Estimator (SANDOSE) is used to estimate total radiation dose to a (BRL-CAT) solid model, SANDOSE uses the mass-sectoring technique to sample the model using ray-tracing techniques. The code is integrated directly into the BRL-CAD solid model editor and is operated using a simple graphical user interface. Several diagnostic tools are available to allow the user to analyze the results. Based on limited validation using several benchmark problems, results can be expected to fall between a 10% underestimate and a factor of 2 overestimate of the actual dose predicted by rigorous radiation transport techniques. However, other situations may be encountered where the results might fall outside of this range. The code is written in C and uses X-windows graphics. It presently runs on SUN SPARCstations, but in theory could be ported to any workstation with a C compiler and X-windows. SANDOSE is available via license by contacting either the Sandia National Laboratories Technology Transfer Center or the author

  11. Pattern imprinting in deep sub-micron static random access memories induced by total dose irradiation

    International Nuclear Information System (INIS)

    Zheng Qi-Wen; Yu Xue-Feng; Cui Jiang-Wei; Guo Qi; Ren Di-Yuan; Cong Zhong-Chao; Zhou Hang

    2014-01-01

    Pattern imprinting in deep sub-micron static random access memories (SRAMs) during total dose irradiation is investigated in detail. As the dose accumulates, the data pattern of memory cells loading during irradiation is gradually imprinted on their background data pattern. We build a relationship between the memory cell's static noise margin (SNM) and the background data, and study the influence of irradiation on the probability density function of ΔSNM, which is the difference between two data sides' SNMs, to discuss the reason for pattern imprinting. Finally, we demonstrate that, for micron and deep sub-micron devices, the mechanism of pattern imprinting is the bias-dependent threshold shift of the transistor, but for a deep sub-micron device the shift results from charge trapping in the shallow trench isolation (STI) oxide rather than from the gate oxide of the micron-device. (condensed matter: structural, mechanical, and thermal properties)

  12. Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

    International Nuclear Information System (INIS)

    Martin, K.E.; Gauthier, M.K.; Coss, J.R.; Dantas, A.R.V.; Price, W.E.

    1986-05-01

    Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose

  13. Pattern imprinting in deep sub-micron static random access memories induced by total dose irradiation

    Science.gov (United States)

    Zheng, Qi-Wen; Yu, Xue-Feng; Cui, Jiang-Wei; Guo, Qi; Ren, Di-Yuan; Cong, Zhong-Chao; Zhou, Hang

    2014-10-01

    Pattern imprinting in deep sub-micron static random access memories (SRAMs) during total dose irradiation is investigated in detail. As the dose accumulates, the data pattern of memory cells loading during irradiation is gradually imprinted on their background data pattern. We build a relationship between the memory cell's static noise margin (SNM) and the background data, and study the influence of irradiation on the probability density function of ΔSNM, which is the difference between two data sides' SNMs, to discuss the reason for pattern imprinting. Finally, we demonstrate that, for micron and deep sub-micron devices, the mechanism of pattern imprinting is the bias-dependent threshold shift of the transistor, but for a deep sub-micron device the shift results from charge trapping in the shallow trench isolation (STI) oxide rather than from the gate oxide of the micron-device.

  14. SU-E-T-515: Field-In-Field Compensation Technique Using Multi-Leaf Collimator to Deliver Total Body Irradiation (TBI) Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [The State University of New York at Buffalo (United States); Wang, IZ [The State University of New York at Buffalo (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2014-06-01

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient's immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has been used conventionally to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern field-in-field (FIF) technique with the multi-leaf collimator (MLC) to more accurately and efficiently deliver dose to patients in need of TBI. Method: Treatment plans utilizing the FIF technique to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Treatment fields include one pair of opposed open large fields (collimator=45°) with a specific weighting and a succession of smaller fields (collimator=90°) each with their own weighting. The smaller fields are shaped by moving MLC to block the sections of the patient which have already received close to 100% of the prescribed dose. The weighting factors for each of these fields were calculated using the attenuation coefficient of the initial lead compensators and the separation of the patient in different positions in the axial plane. Results: Dose-volume histograms (DVH) were calculated for evaluating the FIF compensation technique. The maximum body doses calculated from the DVH were reduced from the non-compensated 179.3% to 148.2% in the FIF plans, indicating a more uniform dose with the FIF compensation. All calculated monitor units were well within clinically acceptable limits and exceeded those of the original lead compensation plan by less than 50 MU (only ~1.1% increase). Conclusion: MLC FIF technique for TBI will not significantly increase the beam on time while it can substantially reduce the compensator setup time and the potential risk of errors in manually placing lead compensators.

  15. The review of radiation effects of γ total dose in CMOS circuits

    International Nuclear Information System (INIS)

    Chen Panxun; Gao Wenming; Xie Zeyuan; Mi Bang

    1992-01-01

    Radiation performances of commercial and rad-hard CMOS circuits are reviewed. Threshold voltage, static power current, V in -V out characteristic and propagation delay time related with total dose are presented for CMOS circuits from several manufacturing processes. The performance of radiation-annealing of experimental circuits had been observed for two years. The comparison has been made between the CMOS circuits made in China and the commercial RCA products. 60 Co γ source can serve as γ simulator of the nuclear explosion

  16. Unscheduled DNA synthesis in spleen cells of mice exposed to low doses of total body irradiation

    International Nuclear Information System (INIS)

    Tuschl, H.; Kovac, R.; Hruby, E.

    1983-07-01

    Unscheduled DNA synthesis was induced by UV irradiation of spleen cells obtained from C 57 Bl mice after repeated total body irradiation of 0.05 Gy 60 Co (0.00125 Gy/mice) and determined autoradiographically. An enhancement in the ability for repair of UV induced DNA lesions was observed in cells of gamma irradiated animals. While the amount of 3 H-thymidine incorporated per cell was increased, the percentage of labeled cells remained unchanged. The present results are compared with previous data on low dose radiation exposure in men. (Author) [de

  17. Prescribing procrastination

    Science.gov (United States)

    Thomson, George H.

    1979-01-01

    In his everyday work the family physician sees many patients whose problems have been diagnosed but for whom postponement of an active treatment plan is indicated. The physician must therefore prescribe procrastination in a carefully planned way. I describe some ideas and practical methods for doing this. PMID:529244

  18. The biological effects of high dose total body irradiation in beagle dogs

    International Nuclear Information System (INIS)

    Luo Qingliang; Liu Xiaolan; Hao Jing; Xiong Guolin; Dong Bo; Zhao Zhenhu; Xia Zhengbiao; Qiu Liling; Mao Bingzhi

    2002-01-01

    Objective: To evaluate the biological effects of Beagle dogs irradiated by γ-rays at different doses. Methods: All Beagle dogs were divided into six groups and were subjected respectively to total-body irradiation (TBI) with a single dose of 6.5, 5.5, 5.0, 4.5, 3, 5 and 2.5 Gy γ-rays delivered by 60 Co sources at 7.224 x 10 -2 C/kg per minute. The general condition, blood cell counts and bone marrow cell CFC assays were observed. Results: Vomiting occurred at 0.5 to 2 hours after TBI in all groups. In 6.5 Gy group 3/5 dogs had blood-watery stool and 1/5 in 5.5 Gy group had watery stool. Diarrhea occurred in all other animals. Only one dog in 2.5 Gy group survived, all of others died. in order of decreasing irradiation dosage, the average survival time was 5.0, 8.0, 9.3, 9.5, 10.5 and 14.1 days, respectively. Conclusions: According to the clinical symptoms, leukocyte count and survival time of the dogs, the irradiation dose which will induce very severe hematopoietic radiation syndrome in Beagle dogs is 4.5 to 5.0 Gy

  19. The effect of low-dose total body irradiation on tumor control

    International Nuclear Information System (INIS)

    Sakamoto, Kiyohiko; Miyamoto, Miyako; Watabe, Nobuyuki.

    1987-01-01

    Total body irradiation (TBI) is considered to bring about an immunosuppressive effect on an organism, on the basis of data obtained from sublethal doses of TBI. However, there are no data on how low-dose TBI affects an organism. Over the last five years, we have been studying the effects of low-dose TBI on normal or tumor-bearing mice and the immunological background of these effects. In experimental studies, an increase in the TD50 value (the number of cells required for a tumor incidence of 50 %) in mice exposed to 10 rad was recognized and showed a remarkable increase at 6 hours to 15 hours after irradiation. TBI of 10 rad also showed an enhancement effect on tumor cell killing when given 12 hours before local tumor irradiation. In order to clarify the mechanism of this kind of effect, some immunological studies were performed using several immunological procedures, and the results suggested that 10 rad of TBI caused increasing tumor immunity in irradiated mice. Clinical trials in some patients with advanced tumors are now being undertaken on the basis of these experimental data, and the effect of TBI on tumor control appears promising, although it is too early to draw conclusions. (author)

  20. Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation

    International Nuclear Information System (INIS)

    Kal, H.B.; Kempen-Harteveld, M.L. van; Heijenbrok-Kal, M.H.; Struikmans, H.

    2006-01-01

    Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled relative risk (RR) was calculated for the treatments with high BED values versus treatments with a low BED. BED-effect relationships were obtained. Results: RRs for the high BED treatments were significantly lower for relapse incidence, not significantly different for disease-free survival and treatment-related mortality, and significantly higher for overall survival. BED-effect relationships indicate a decrease in relapse incidence and treatment-related mortality and an increase in disease-free and overall survival with higher BED values. Conclusion: 'More dose is better', provided that a TBI setting is used limiting the BEDs of lungs, kidneys, and eye lenses. (orig.)

  1. In pediatric leukemia, dose evaluation according to the type of compensators in total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yeon [Dongnam Inst. of Radiological and Medical science, Busan (Korea, Republic of); Kim, Chang Soo; Kim, Jung Hoon [Dept. of Radiological Science, College of Health Science, Catholic University of Busan, Busan (Korea, Republic of)

    2015-04-15

    Total body irradiation (TBI) and chemotherapy are the pre-treatment method of a stem cell transplantations of the childhood leukemia. in this study, we evaluate the Quantitative human body dose prior to the treatment. The MCNPX simulation program evaluated by changing the material of the tissue compensators with imitation material of pediatric exposure in a virtual space. As a result, first, the average skin dose with the material of the tissue compensators of Plexiglass tissue compensators is 74.60 mGy/min, Al is 73.96 mGy/min, Cu is 72.26 mGy/min and Pb 67.90 mGy/min respectively. Second, regardless of the tissue compensators material that organ dose were thyroid, gentile, digestive system, brain, lungs, kidneys higher in order. Finally, the ideal distance between body compensator and the patient were 50 cm aparting each other. In conclusion, tissue compensators Al, Cu, Pb are able to replace of the currently used in Plexiglass materials.

  2. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars

    2015-01-01

    a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. RESULTS: The overall response rate was 95% with a complete cutaneous response......PURPOSE: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments...... or a very good partial response rate (response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. CONCLUSIONS...

  3. A first-principles approach to total-dose hardness assurance

    International Nuclear Information System (INIS)

    Fleetwood, D.M.

    1995-01-01

    A first-principles approach to radiation hardness assurance was described that provides the technical background to the present US and European total-dose radiation hardness assurance test methods for MOS technologies, TM 1019.4 and BS 22900. These test methods could not have been developed otherwise, as their existence depends not on a wealth of empirical comparisons of IC data from ground and space testing, but on a fundamental understanding of MOS defect growth and annealing processes. Rebound testing should become less of a problem for advanced MOS small-signal electronics technologies for systems with total dose requirements below 50--100 krad(SiO 2 ) because of trends toward much thinner gate oxides. For older technologies with thicker gate oxides and for power devices, rebound testing is unavoidable without detailed characterization studies to assess the impact of interface traps on devices response in space. The QML approach is promising for future hardened technologies. A sufficient understanding of process effects on radiation hardness has been developed that should be able to reduce testing costs in the future for hardened parts. Finally, it is hoped that the above discussions have demonstrated that the foundation for cost-effective hardness assurance tests is laid with studies of the basic mechanisms of radiation effects. Without a diligent assessment of new radiation effects mechanisms in future technologies, one cannot be assured that the present generation of radiation test standards will continue to apply

  4. A rapid infusion protocol is safe for total dose iron polymaltose: time for change.

    Science.gov (United States)

    Garg, M; Morrison, G; Friedman, A; Lau, A; Lau, D; Gibson, P R

    2011-07-01

    Intravenous correction of iron deficiency by total dose iron polymaltose is inexpensive and safe, but current protocols entail prolonged administration over more than 4 h. This results in reduced patient acceptance, and hospital resource strain. We aimed to assess prospectively the safety of a rapid intravenous protocol and compare this with historical controls. Consecutive patients in whom intravenous iron replacement was indicated were invited to have up to 1.5 g iron polymaltose by a 58-min infusion protocol after an initial 15-min test dose without pre-medication. Infusion-related adverse events (AE) and delayed AE over the ensuing 5 days were also prospectively documented and graded as mild, moderate or severe. One hundred patients, 63 female, mean age 54 (range 18-85) years were studied. Thirty-four infusion-related AE to iron polymaltose occurred in a total of 24 patients--25 mild, 8 moderate and 1 severe; higher than previously reported for a slow protocol iron infusion. Thirty-one delayed AE occurred in 26 patients--26 mild, 3 moderate and 2 severe; similar to previously reported. All but five patients reported they would prefer iron replacement through the rapid protocol again. The presence of inflammatory bowel disease (IBD) predicted infusion-related reactions (54% vs 14% without IBD, P cost, resource utilization and time benefits for the patient and hospital system. © 2011 The Authors. Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  5. Influence of burn-in on total-ionizing-dose effect of SRAM device

    International Nuclear Information System (INIS)

    Liu Minbo; Yao Zhibin; Huang Shaoyan; He Baoping; Sheng Jiangkun

    2014-01-01

    The influence of Burn-in on the total-ionizing-dose (TID) effect of SRAM device was investigated. SRAM devices of three different feature sizes were selected and irradiated by "6"0Co source with or without pre-irradiation Burn-in. Some parameters for radiation effect of SRAM device such as upset data, were measured, and the influence on the TID effect of different feature size SRAM devices with or without pre-irradiation Burn-in was obtained. The influence of different temperature Burn-in on radiation resistant capability of SRAM device was studied for 0.25 μm SRAM device. The results show that the smaller the device feature size is, the better the radiation-resistant capability of SRAM device is and the weaker the influence of Burn-in is. And the higher Burn-in temperature is, the more serious the influence of Burn-in on the total-dose radiation effect is. (authors)

  6. Total Ambient Dose Equivalent Buildup Factor Determination for Nbs04 Concrete.

    Science.gov (United States)

    Duckic, Paulina; Hayes, Robert B

    2018-06-01

    Buildup factors are dimensionless multiplicative factors required by the point kernel method to account for scattered radiation through a shielding material. The accuracy of the point kernel method is strongly affected by the correspondence of analyzed parameters to experimental configurations, which is attempted to be simplified here. The point kernel method has not been found to have widespread practical use for neutron shielding calculations due to the complex neutron transport behavior through shielding materials (i.e. the variety of interaction mechanisms that neutrons may undergo while traversing the shield) as well as non-linear neutron total cross section energy dependence. In this work, total ambient dose buildup factors for NBS04 concrete are calculated in terms of neutron and secondary gamma ray transmission factors. The neutron and secondary gamma ray transmission factors are calculated using MCNP6™ code with updated cross sections. Both transmission factors and buildup factors are given in a tabulated form. Practical use of neutron transmission and buildup factors warrants rigorously calculated results with all associated uncertainties. In this work, sensitivity analysis of neutron transmission factors and total buildup factors with varying water content has been conducted. The analysis showed significant impact of varying water content in concrete on both neutron transmission factors and total buildup factors. Finally, support vector regression, a machine learning technique, has been engaged to make a model based on the calculated data for calculation of the buildup factors. The developed model can predict most of the data with 20% relative error.

  7. Prescribing Antibiotics

    DEFF Research Database (Denmark)

    Pedersen, Inge Kryger; Jepsen, Kim Sune

    2018-01-01

    The medical professions will lose an indispensable tool in clinical practice if even simple infections cannot be cured because antibiotics have lost effectiveness. This article presents results from an exploratory enquiry into “good doctoring” in the case of antibiotic prescribing at a time when...... the knowledge base in the healthcare field is shifting. Drawing on in-depth interviews about diagnosing and prescribing, the article demonstrates how the problem of antimicrobial resistance is understood and engaged with by Danish general practitioners. When general practitioners speak of managing “non......-medical issues,” they refer to routines, clinical expertise, experiences with their patients, and decision-making based more on contextual circumstances than molecular conditions—and on the fact that such conditions can be hard to assess. This article’s contribution to knowledge about how new and global health...

  8. Northern Marshall Islands radiological survey: terrestrial food chain and total doses

    International Nuclear Information System (INIS)

    Robison, W.L.; Mount, M.E.; Phillips, W.A.; Conrado, C.A.; Stuart, M.L.; Stoker, C.E.

    1982-01-01

    A radiological survey was conducted from September through November of 1978 to assess the concentrations of persistent manmade radionuclides in the terrestrial and marine environments of 11 atolls and 2 islands in the Northern Marshall Islands. The survey consisted mainly of an aerial radiological reconnaissance to map the external gamma-ray exposure rates over the islands of each atoll. The logistical support for the entire survey was designed to accommodate this operation. As a secondary phase of the survey, shore parties collected appropriate terrestrial and marine samples to assess the radiological dose from pertinent food chains to those individuals residing on the atolls, who may in the future reside on some of the presently uninhabited atolls, or who collect food from these atolls. Over 5000 terrestrial and marine samples were collected for radionuclide analysis from 76 different islands. Soils, vegetation, indigenous animals, and cistern water and groundwater were collected from the islands. Reef and pelagic fish, clams, lagoon water, and sediments were obtained from the lagoons. The concentration data for 90 Sr, 137 Cs, 238 Pu, 239 240 Pu, and 241 Am in terrestrial food crops, fowl, and animals collected at the atolls or islands are summarized. An assessment of the total dose from the major exposure pathways including external gamma, terrestrial food chain including food products and drinking water, marine food chain, and inhalation is provided. Radiological doses at each atoll or island are calculated from the average radionuclide concentrations in the terrestrial foods, marine foods, etc. assuming the average daily intake for each food item

  9. High Total Ionizing Dose and Temperature Effects on Micro- and Nano-electronic Devices

    International Nuclear Information System (INIS)

    Gaillardin, M.; Martinez, M.; Paillet, P.; Leray, J.L.; Marcandella, C.; Duhamel, O.; Raine, M.; Richard, N.; Girard, S.; Ouerdane, Y.; Boukenter, A.; Goiffon, V.; Magnan, P.; Andrieu, F.; Barraud, S.; Faynot, O.

    2013-06-01

    This paper investigates the vulnerability of several micro- and nano-electronic technologies to a mixed harsh environment including high total ionizing dose at MGy levels and high temperature. Such operating conditions have been revealed recently for several applications like new security systems in existing or future nuclear power plants, fusion experiments, or deep space missions. In this work, the competing effects already reported in literature of ionizing radiations and temperature are characterized in elementary devices made of MOS transistors from several technologies. First, devices are irradiated using a radiation laboratory X-ray source up to MGy dose levels at room temperature. Devices are grounded during irradiation to simulate a circuit which waits for a wake up signal, representing most of the lifetime of an integrated circuit operating in a harsh environment. Devices are then annealed at several temperatures to discuss the post-irradiation behavior and to determine whether an elevated temperature is an issue or not for circuit function in mixed harsh environments. (authors)

  10. Anti-tumor effect of total body irradiation of low doses on WHT/Ht mice

    International Nuclear Information System (INIS)

    Miyamoto, Miyako; Sakamoto, Kiyohiko

    1987-01-01

    The effect of low dose (0.05 - 1.0 Gy) of total body irradiation (TBI) on non-tumor bearing and tumor bearing mice were investigated. Mice received TBI of 0.1 Gy during 6 - 12 hours before tumor cell inoculation demonstrated to need larger number of tumor cells (approximately 2.5 times) for 50 per cent tumor incidence, compared to recipient mice not to receive TBI. On the other hand, in tumor bearing mice given 0.1 Gy of TBI only tumor cell killing effect was not detected, however enhancement of tumor cell killing effect and prolonged growth delay were observed when tumor bearing mice were treated with 0.1 Gy of TBI in combined with local irradiation on tumors, especially cell killing effect was remarkable in dose range over 6 Gy of local exposure. The mechanism of the effect of 0.1 Gy TBI is considered to be host mediated reactions from the other our experimental results. (author)

  11. Total dose radiation effects of pressure sensors fabricated on uni-bond-SOI materials

    International Nuclear Information System (INIS)

    Zhu Shiyang; Huang Yiping; Wang Jin; Li Anzhen; Shen Shaoqun; Bao Minhang

    2001-01-01

    Piezoresistive pressure sensors with a twin-island structure were successfully fabricated using high quality Uni-bond-SOI (On Insulator) materials. Since the piezoresistors were structured by the single crystalline silicon overlayer of the SOI wafer and were totally isolated by the buried SiO 2 , the sensors are radiation-hard. The sensitivity and the linearity of the pressure sensors keep their original values after being irradiated by 60 Co γ-rays up to 2.3 x 10 4 Gy(H 2 O). However, the offset voltage of the sensor has a slight drift, increasing with the radiation dose. The absolute value of the offset voltage deviation depends on the pressure sensor itself. For comparison, corresponding polysilicon pressure sensors were fabricated using the similar process and irradiated at the same condition

  12. Characterization of total ionizing dose damage in COTS pinned photodiode CMOS image sensors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zujun, E-mail: wangzujun@nint.ac.cn; Ma, Wuying; Huang, Shaoyan; Yao, Zhibin; Liu, Minbo; He, Baoping; Sheng, Jiangkun; Xue, Yuan [State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an, Shaanxi 710024 (China); Liu, Jing [School of Materials Science and Engineering, Xiangtan University, Hunan (China)

    2016-03-15

    The characterization of total ionizing dose (TID) damage in COTS pinned photodiode (PPD) CMOS image sensors (CISs) is investigated. The radiation experiments are carried out at a {sup 60}Co γ-ray source. The CISs are produced by 0.18-μm CMOS technology and the pixel architecture is 8T global shutter pixel with correlated double sampling (CDS) based on a 4T PPD front end. The parameters of CISs such as temporal domain, spatial domain, and spectral domain are measured at the CIS test system as the EMVA 1288 standard before and after irradiation. The dark current, random noise, dark signal non-uniformity (DSNU), photo response non-uniformity (PRNU), overall system gain, saturation output, dynamic range (DR), signal to noise ratio (SNR), quantum efficiency (QE), and responsivity versus the TID are reported. The behaviors of the tested CISs show remarkable degradations after radiation. The degradation mechanisms of CISs induced by TID damage are also analyzed.

  13. Total-ionizing-dose effects on isolation oxides in modern CMOS technologies

    International Nuclear Information System (INIS)

    Barnaby, Hugh J.; Mclain, Michael; Esqueda, Ivan Sanchez

    2007-01-01

    This paper presents experimental data on the total dose response of deep sub-micron bulk CMOS devices and integrated circuits. Ionizing radiation experiments on shallow trench isolation (STI) field oxide MOS capacitors (FOXCAP) indicate a characteristic build-up of radiation-induced defects in the dielectric. In this paper, capacitors fabricated with STI, thermal, SIMOX and bipolar base oxides of similar thickness are compared and show the STI oxide to be most susceptible to radiation effects. Experimental data on irradiated shift registers and n-channel MOSFETs are also presented. These data indicate that radiation damage to the STI can increase the off-state current of n-channel devices and the standby current of CMOS integrated circuits

  14. New insights into fully-depleted SOI transistor response during total-dose irradiation

    International Nuclear Information System (INIS)

    Schwank, J.R.; Shaneyfelt, M.R.; Dodd, P.E.; Burns, J.A.; Keast, C.L.; Wyatt, P.W.

    1999-01-01

    In this paper, we present irradiation results on 2-fully depleted processes (HYSOI6, RKSOI) that show SOI (silicon on insulator) device response can be more complicated than originally suggested by others. The major difference between the 2 process versions is that the RKSOI process incorporates special techniques to minimize pre-irradiation parasitic leakage current from trench sidewalls. Transistors were irradiated at room temperature using 10 keV X-ray source. Worst-case bias configuration for total-dose testing fully-depleted SOI transistors was found to be process dependent. It appears that the worst-case bias for HYPOI6 process is the bias that causes the largest increase in sidewall leakage. The RKSOI process shows a different response during irradiation, the transition response appears to be dominated by charge trapping in the buried oxide. These results have implications for hardness assurance testing. (A.C.)

  15. Origins of Total-Dose Response Variability in Linear Bipolar Microcircuits

    International Nuclear Information System (INIS)

    Barnaby, H.J.; Cirba, C.R.; Schrimpf, R.D.; Fleetwood, D.M.; Pease, R.L.; Shaneyfelt, Marty R.; Turflinger, T.; Krieg, J.F.; Maher, M.C.

    2000-01-01

    LM1ll voltage comparators exhibit a wide range of total-dose-induced degradation. Simulations show this variability may be a natural consequence of the low base doping of the substrate PNP (SPNP) input transistors. Low base doping increases the SPNP's collector to base breakdown voltage, current gain, and sensitivity to small fluctuations in the radiation-induced oxide defect densities. The build-up of oxide trapped charge (N ot ) and interface traps (N it ) is shown to be a function of pre-irradiation bakes. Experimental data indicate that, despite its structural similarities to the LM111, irradiated input transistors of the LM124 operational amplifier do not exhibit the same sensitivity to variations in pre-irradiation thermal cycles. Further disparities in LM111 and LM124 responses may result from a difference in the oxide defect build-up in the two part types. Variations in processing, packaging, and circuit effects are suggested as potential explanations

  16. Clinical study on the adriamycin induced cardiomyopathy using the cardiac magnetic resonance imaging. Total dose and cardiac dysfunction

    International Nuclear Information System (INIS)

    Yamaguchi, Kyoko; Teraoka, Kunihiko; Hirano, Masaharu

    2001-01-01

    We studied cardiac functional disorders caused by Adoriamycin using gadolinium (Gd) contrast cine MRI. Forty-eight patients were given ACT (31 men and 17 women; mean age, 52±15 years). First, the relationship between dose and the left ventricular volume, cardiac function, left ventricular cardiac mass and localized wall motion were examined in all patients. Patients given a total dose of 300 mg/m 2 or higher were assigned to the high dose group and those given doses under 300 mg/m 2 to the low dose group. The same parameters were studied in both groups and compared. A 1.5-Tesla superconductive MRI was used for all studies. Cine images of the long and short axes at the papillary muscle level were obtained by ECG R-wave synchronized Gd contrast cine MRI. Left ventricular volume and cardiac function were analyzed using the long-axis cine images and the wall thickness in diastole and systole was measured at each site using the short-axis cine images. The percentage of wall thickness was calculated at each site. The mean ACT dose was 273.3±218.2 mg/m 2 . In all patients the total dose directly correlated with ESVI and inversely correlated with the ejection fraction (EF). In the high dose group, the total dose and EF were inversely correlated, but no significant differences were observed in the low dose group. In the high dose group, the ESVI was significantly greater and the SVI and EF were more significantly reduced than in the low dose group. In the high dose group, the thickness of the anterior, lateral and posterior walls, excluding the septum, was significantly lower than in the low dose group. However, changes in wall thickness were not significantly different between the groups. Gd contrast cine MRI was useful in examining cardiac functional disorders caused by anthracyclines. The total dose of anthracycline correlated directly with the ESVI, and inversely with the EF. A total dose of 300 mg/m 2 appeared to be the borderline dose beyond which there were

  17. Clinical study on the adriamycin induced cardiomyopathy using the cardiac magnetic resonance imaging. Total dose and cardiac dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Kyoko; Teraoka, Kunihiko; Hirano, Masaharu [Tokyo Medical Coll. (Japan)

    2001-05-01

    We studied cardiac functional disorders caused by Adoriamycin using gadolinium (Gd) contrast cine MRI. Forty-eight patients were given ACT (31 men and 17 women; mean age, 52{+-}15 years). First, the relationship between dose and the left ventricular volume, cardiac function, left ventricular cardiac mass and localized wall motion were examined in all patients. Patients given a total dose of 300 mg/m{sup 2} or higher were assigned to the high dose group and those given doses under 300 mg/m{sup 2} to the low dose group. The same parameters were studied in both groups and compared. A 1.5-Tesla superconductive MRI was used for all studies. Cine images of the long and short axes at the papillary muscle level were obtained by ECG R-wave synchronized Gd contrast cine MRI. Left ventricular volume and cardiac function were analyzed using the long-axis cine images and the wall thickness in diastole and systole was measured at each site using the short-axis cine images. The percentage of wall thickness was calculated at each site. The mean ACT dose was 273.3{+-}218.2 mg/m{sup 2}. In all patients the total dose directly correlated with ESVI and inversely correlated with the ejection fraction (EF). In the high dose group, the total dose and EF were inversely correlated, but no significant differences were observed in the low dose group. In the high dose group, the ESVI was significantly greater and the SVI and EF were more significantly reduced than in the low dose group. In the high dose group, the thickness of the anterior, lateral and posterior walls, excluding the septum, was significantly lower than in the low dose group. However, changes in wall thickness were not significantly different between the groups. Gd contrast cine MRI was useful in examining cardiac functional disorders caused by anthracyclines. The total dose of anthracycline correlated directly with the ESVI, and inversely with the EF. A total dose of 300 mg/m{sup 2} appeared to be the borderline dose beyond

  18. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  19. The carcinogenic risk of high dose total body irradiation in non-human primates

    International Nuclear Information System (INIS)

    Broerse, J.J.; Bartstra, R.W.; Bekkum, D.W. van; Hage, M.H. van der; Zurcher, C.; Zwieten, M.J. van; Hollander, C.F.

    2000-01-01

    High dose total body irradiation (TBI) in combination with chemotherapy, followed by rescue with bone marrow transplantation (BMT), is increasingly used for the treatment of haematological malignancies. With the increasing success of this treatment and its current introduction for treating refractory autoimmune diseases the risk of radiation carcinogenesis is of growing concern. Studies on turnout induction in non-human primates are of relevance in this context since the response of this species to radiation does not differ much from that in man. Since the early sixties, studies have been performed on acute effects in Rhesus monkeys and the protective action of bone marrow transplantation after irradiation with X-rays (average total body dose 6.8 Gy) and fission neutrons (average dose 3.4 Gy). Of those monkeys, which were irradiated and reconstituted with autologous bone marrow, 20 animals in the X-irradiated group and nine animals in the neutron group survived more than 3 years. A group of 21 non-irradiated Rhesus monkeys of a comparable age distribution served as controls. All animals were regularly screened for the occurrence of neoplasms. Complete necropsies were performed after natural death or euthanasia. At post-irradiation intervals of 4-21 years an appreciable number of tumours was observed. In the neutron irradiated group eight out of nine animals died with one or more malignant tumours. In the X-irradiated group this fraction was 10 out of 20. The tumours in the control group, in seven out of the 21 animals, appeared at much older a-e compared with those in the irradiated cohorts. The histogenesis of the tumours was diverse with a preponderance of renal carcinoma, sarcomas among which osteosarcormas, and malignant glomus tumours in the irradiated groups. When corrected for competing risks, the carcinogenic risk of TBI in the Rhesus monkeys is similar to that derived from the studies of the Japanese atomic bomb survivors. The increase of the risk by a

  20. Influence of radioprotectors on total body weight evolution and on oxygen consumption in lethal dose irradiated animals. (Preliminary study)

    International Nuclear Information System (INIS)

    Fatome, M.; Martine, G.; Bargy, E.; Andrieu, L.

    Comparison of total body weight evolution and oxygen consumption in lethal dose irradiated animals, protected by various well known radioprotective substances, isolated or in mixture, with evolution and consumption of non protected animals irradiated at the same dose and with these of check animals [fr

  1. Fractionated total body irradiation and autologous bone marrow transplantation in dogs: Hemopoietic recovery after various marrow cell doses

    International Nuclear Information System (INIS)

    Bodenburger, U.; Kolb, H.J.; Thierfelder, S.; Netzel, B.; Schaeffer, E.; Kolb, H.

    1980-01-01

    Hemopoietic recovery was studied in dogs given 2400 R fractionated total body irradiation within one week and graded doses of cryopreserved autologous bone marrow. Complete hemopoietic recovery including histology was observed after this dose and sufficient doses of marrow cells. Doses of more than 5.5 x 10 7 mononuclear marrow cells/kg body weight were sufficient for complete recovery in all dogs, 1.5 to 5.5 x 10 7 cells/kg were effective in some of the dogs and less than 1.5 x 10 7 cells/kg were insufficient for complete recovery. Similarly, more than 30000 CFUsub(c)/kg body weight were required for hemopoietic recovery. The optimal marrow cell dose which has been defined as the minimal dose required for the earliest possible recovery of leukocyte and platelet counts was 7-8 x 10 7 mononuclear marrow cells/kg body weight. It has been concluded that fractionated total body irradiation with 2400 R dose not require greater doses of marrow cells for hemopoietic reconstitution than lower single doses and that the hemopoietic microenvironment is not persistently disturbed after this dose. (author)

  2. Synergistic effects of total ionizing dose on single event upset sensitivity in static random access memory under proton irradiation

    International Nuclear Information System (INIS)

    Xiao Yao; Guo Hong-Xia; Zhang Feng-Qi; Zhao Wen; Wang Yan-Ping; Zhang Ke-Ying; Ding Li-Li; Luo Yin-Hong; Wang Yuan-Ming; Fan Xue

    2014-01-01

    Synergistic effects of the total ionizing dose (TID) on the single event upset (SEU) sensitivity in static random access memories (SRAMs) were studied by using protons. The total dose was cumulated with high flux protons during the TID exposure, and the SEU cross section was tested with low flux protons at several cumulated dose steps. Because of the radiation-induced off-state leakage current increase of the CMOS transistors, the noise margin became asymmetric and the memory imprint effect was observed. (interdisciplinary physics and related areas of science and technology)

  3. Total dose and dose-rate effects on start-up current in anti-fuse FPGA

    International Nuclear Information System (INIS)

    Wang, J.; Wong, W.; McCollum, J.; Cronquist, B.; Katz, R.; Kleyner, I.; Kleyner, F.

    1999-01-01

    Radiation enhanced start-up current (RESC) in an anti-fuse FPGA, A1280A, is thoroughly investigated and a comprehensive transistor-level mechanism is proposed. Low dose-rate testing, appropriate for civilian space applications, and annealing at room temperature shows RESC to be negligible for the lot of parts tested with a fixed power supply slew rate. (authors)

  4. Laboratory Bioaccumulation, Depuration And Total Dose Rate Of Waterborne Th-232 In Freshwater Fish Of Anabas Testudineus

    International Nuclear Information System (INIS)

    Zal U'yun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2014-01-01

    Preliminary results on the study of bioaccumulation, depuration and total dose rate of Th-232 in the whole body of Anabas testudineus are presented. The objective of this study was to evaluate the effect of Th-232 concentration activity on the laboratory bioaccumulation, depuration and total dose rate in Anabas testudineus. Anabas testudineus adults were exposed to different waterborne Th-232 levels: 0 BqL -1 (control), 50 BqL -1 and 100 BqL -1 for 30 day (uptake phase), followed by exposure to radionuclide-free water for 30 days (loss phase). Radionuclide concentration ratios between the whole body levels and water levels, percentage of Th-232 remaining in fish were calculated and total dose rates using ERICA Assessment Tool were also estimated. The results showed the increase of waterborne Th-232 concentration corresponded to a progressive increase of Th accumulation and total dose rate (internal and external) in the whole body of Anabas testudineus. Considering the ERICA dose rate screening value of 10 μGyh -1 , the findings can be concluded the estimated of total dose rate (< 5 μGyh -1 ) in Anabas testudineus is in order of small magnitude. Nevertheless, these preliminary results showed that the Anabas testudineus has a potential to accumulate thorium. (author)

  5. [Single intravenous tranexamic acid dose to reduce blood loss in primary total knee replacement].

    Science.gov (United States)

    Sanz-Reig, J; Parra Ruiz, B; Ferrández Martínez, J; Martínez López, J F

    2016-01-01

    To evaluate the effectiveness and safety of a single intravenous dose of tranexamic acid in order to reduce blood loss in total knee replacement. Prospective observational study of the administration of tranexamic acid in patients undergoing primary total knee arthroplasty from November 2013 to February 2015, in which an autologous blood recovery system was used. The study included 98 patients, distributed into two groups of 49 patients according to whether or not they received intravenous tranexamic acid. The primary endpoint was the number of patients requiring autologous transfusion from the recovery system autologous blood recovery system. No drop-outs were recorded during follow-up. There were no significant differences between groups as regards the preoperative and hospital variables. The mean preoperative haemoglobin and haematocrit at 24 and 48 hours postoperatively were similar in both groups. The average volume of bleeding in the autologous blood recovery system and estimated average blood loss was lower in patients who had been administered tranexamic acid, with significant differences. No patients in the group that was administered tranexamic acid required blood autotransfusion. The transfusion rate was zero in the two groups. No adverse events related to the administration of tranexamic acid were recorded. Intravenous administration of tranexamic acid, according to the described protocol, has presented a non-autotransfusion or allo-transfusion rate of 100%, with no increased incidence of thrombotic events. Thus, its use in this group of patients is recommended. The indication should be individualized, its use justified in the patient medical records, and informed consent is mandatory. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  6. Effect of high-dose preoperative methylprednisolone on recovery after total hip arthroplasty

    DEFF Research Database (Denmark)

    Lunn, T H; Andersen, Lasse Østergaard; Kristensen, B B

    2013-01-01

    (IQR) (95% CI), MP vs placebo]: 23.5 (23.3-23.7) (17.8-43.8) vs 23.5 (23.0-23.8) (20.0-46.8) h, the mean difference (95% CI) being -1.3 (-4.7 to 2.2) h, P=0.65. Overall pain for the first 24 h after surgery was significantly reduced in the MP vs the placebo group (PMP 125 mg i.v. before surgery added......BACKGROUND: /st>High-dose glucocorticoid may reduce postsurgical pain and improve recovery. We hypothesized that 125 mg methylprednisolone (MP) would reduce time to meet functional discharge criteria after total hip arthroplasty (THA). METHODS: /st>Forty-eight patients undergoing unilateral THA...... under spinal anaesthesia were consecutively included in this randomized, double-blind, placebo-controlled trial receiving preoperative i.v. MP or saline. All patients received a standardized, multimodal analgesic regime with paracetamol, celecoxib, and gabapentin. The primary outcome was time to meet...

  7. Total Ionizing Dose effects in 130-nm commercial CMOS technologies for HEP experiments

    CERN Document Server

    Gonella, L; Silvestri, M; Gerardin, S; Pantano, D; Re, V; Manghisoni, M; Ratti, L; Ranieri, A

    2007-01-01

    The impact of foundry-to-foundry variability and bias conditions during irradiation on the Total Ionizing Dose (TID) response of commercial 130-nm CMOS technologies have been investigated for applications in High Energy Physics (HEP) experiments. n- and p-channel MOSFETs from three different manufacturers have been irradiated with X-rays up to more than 100 Mrad (SiO2). Even though the effects of TID are qualitatively similar, the amount of degradation is shown to vary considerably from foundry to foundry, probably depending on the processing of the STI oxide and/or doping profile in the substrate. The bias during irradiation showed to have a strong impact as well on the TID response, proving that exposure at worst case bias conditions largely overestimates the degradation a device may experience during its lifetime. Overall, our results increase the confidence that 130-nm CMOS technologies can be used in future HEP experiments even without Hardness-By-Design solutions, provided that constant monitoring of th...

  8. Optimization of total arc degree for stereotactic radiotherapy by using integral biologically effective dose and irradiated volume

    International Nuclear Information System (INIS)

    Lim, Do Hoon; Kim, Dae Yong; Lee, Myung Za; Chun, Ha Chung

    2001-01-01

    To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. With Xknife-3 planning system and 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, 100 deg, 200 deg, 300 deg, 400 deg, 500 deg, 600 deg, of total arc degrees, and 30 deg or 45 deg of arc intervals were used. After the completion of planning, the plans were compared each other using V 50 (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. At 30 deg of arc interval, the values of V 50 had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval, up to 400 deg of total arc degree, the values of V 50 decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. At 30 deg of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with 50 and 60 mm of collimator diameters, up to 400 deg of total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. In the stereotactic radiotherapy planning for brain lesions, planning with 400 deg of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of 500 deg and 600 deg of total arc degrees make the increase of V 50 and integral biologically effective dose, Therefore stereotactic radiotherapy planning using 400 deg of total arc degree can increase the therapeutic ratio and produce the effective outcome

  9. Modelling normal tissue isoeffect distribution in conformal radiotherapy of glioblastoma provides an alternative dose escalation pattern through hypofractionation without reducing the total dose

    International Nuclear Information System (INIS)

    Mangel, L.; Skriba, Z.; Major, T.; Polgar, C.; Fodor, J.; Somogyi, A.; Nemeth, G.

    2002-01-01

    The purpose of this study was to prove that by using conformal external beam radiotherapy (RT) normal brain structures can be protected even when applying an alternative approach of biological dose escalation: hypofractionation (HOF) without total dose reduction (TDR). Traditional 2-dimensional (2D) and conformal 3-dimensional (3D) treatment plans were prepared for 10 gliomas representing the subanatomical sites of the supratentorial brain. Isoeffect distributions were generated by the biologically effective dose (BED) formula to analyse the effect of conventionally fractionated (CF) and HOF schedules on both the spatial biological dose distribution and biological dose-volume histograms. A comparison was made between 2D-CF (2.0 Gy/day) and 3D-HOF (2.5 Gy/day) regimens, applying the same 60 Gy total doses. Integral biologically effective dose (IBED) and volumes received biologically equivalent to a dose of 54 Gy or more (V-BED54) were calculated for the lower and upper brain stem as organs of risk. The IBED values were lower with the 3D-HOF than with the 2D-CF schedule in each tumour location, means 22.7±17.1 and 40.4±16.9 in Gy, respectively (p<0.0001). The V-BED54 values were also smaller or equal in 90% of the cases favouring the 3D-HOF scheme. The means were 2.7±4.8 ccm for 3D-HOF and 10.7±12.7 ccm for 2D-CF (p=0.0006). Our results suggest that with conformal RT, fraction size can gradually be increased. HOF radiotherapy regimens without TDR shorten the treatment time and seem to be an alternative way of dose escalation in the treatment of glioblastoma

  10. Modelling normal tissue isoeffect distribution in conformal radiotherapy of glioblastoma provides an alternative dose escalation pattern through hypofractionation without reducing the total dose

    Energy Technology Data Exchange (ETDEWEB)

    Mangel, L.; Skriba, Z.; Major, T.; Polgar, C.; Fodor, J.; Somogyi, A.; Nemeth, G. [National Research Inst. for Radiobiology and Radiohygiene, Budapest (Hungary)

    2002-04-01

    The purpose of this study was to prove that by using conformal external beam radiotherapy (RT) normal brain structures can be protected even when applying an alternative approach of biological dose escalation: hypofractionation (HOF) without total dose reduction (TDR). Traditional 2-dimensional (2D) and conformal 3-dimensional (3D) treatment plans were prepared for 10 gliomas representing the subanatomical sites of the supratentorial brain. Isoeffect distributions were generated by the biologically effective dose (BED) formula to analyse the effect of conventionally fractionated (CF) and HOF schedules on both the spatial biological dose distribution and biological dose-volume histograms. A comparison was made between 2D-CF (2.0 Gy/day) and 3D-HOF (2.5 Gy/day) regimens, applying the same 60 Gy total doses. Integral biologically effective dose (IBED) and volumes received biologically equivalent to a dose of 54 Gy or more (V-BED54) were calculated for the lower and upper brain stem as organs of risk. The IBED values were lower with the 3D-HOF than with the 2D-CF schedule in each tumour location, means 22.7{+-}17.1 and 40.4{+-}16.9 in Gy, respectively (p<0.0001). The V-BED54 values were also smaller or equal in 90% of the cases favouring the 3D-HOF scheme. The means were 2.7{+-}4.8 ccm for 3D-HOF and 10.7{+-}12.7 ccm for 2D-CF (p=0.0006). Our results suggest that with conformal RT, fraction size can gradually be increased. HOF radiotherapy regimens without TDR shorten the treatment time and seem to be an alternative way of dose escalation in the treatment of glioblastoma.

  11. Total Skin Electron Beam Therapy in the Treatment of Mycosis Fungoides: A Review of Conventional and Low-Dose Regimens.

    Science.gov (United States)

    Chowdhary, Mudit; Chhabra, Arpit M; Kharod, Shivam; Marwaha, Gaurav

    2016-12-01

    Mycosis fungoides (MF) is the most prevalent subtype of cutaneous T-cell lymphoma, which is characterized by the proliferation of CD4 + T cells. While often an indolent disease, most patients eventually develop progression from isolated patches to tumors and finally nodal or visceral involvement. Treatment choice is largely based on disease burden, though prognostic factors such as disease stage, patient age, and extracutaneous involvement must be taken into consideration. Radiotherapy represents one of the most effective therapeutic modalities in the treatment of MF. Lymphocytes are exquisitely radiosensitive, and excellent responses are observed even with low doses of radiation. Total skin electron beam therapy (TSEBT) is a special technique that allows for the homogenous irradiation of the entire skin. There are well-documented radiation dose-response relationships for achieving a complete response. As such, TSEBT doses ≥ 30 Gy comprise the current standard of care. Although highly effective, most patients experience recurrent disease even after conventional-dose (≥ 30 Gy) TSEBT. In addition, toxicity is cumulatively dose dependent, and there is reluctance to administer multiple courses of conventional-dose TSEBT. Consequently, there has been renewed interest in determining the utility of TSEBT at lower total (≤ 30 Gy) doses. Advantages of low-total-dose (with standard dose per fraction) TSEBT include a shortened treatment course, the potential to minimize the risk of adverse events, and the opportunity to allow for retreatment in cases of disease recurrence. This comprehensive review compares the impact of different TSEBT dosing schemes on clinical outcomes of MF. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Analysis of bias effects on the total ionizing dose response in a 180 nm technology

    International Nuclear Information System (INIS)

    Liu Zhangli; Hu Zhiyuan; Zhang, Zhengxuan; Shao Hua; Chen Ming; Bi Dawei; Ning Bingxu; Zou Shichang

    2011-01-01

    The effects of gamma ray irradiation on the shallow trench isolation (STI) leakage current in a 180 nm technology are investigated. The radiation response is strongly influenced by the bias modes, gate bias during irradiation, substrate bias during irradiation and operating substrate bias after irradiation. We found that the worst case occurs under the ON bias condition for the ON, OFF and PASS bias mode. A positive gate bias during irradiation significantly enhances the STI leakage current, indicating the electric field influence on the charge buildup process during radiation. Also, a negative substrate bias during irradiation enhances the STI leakage current. However a negative operating substrate bias effectively suppresses the STI leakage current, and can be used to eliminate the leakage current produced by the charge trapped in the deep STI oxide. Appropriate substrate bias should be introduced to alleviate the total ionizing dose (TID) response, and lead to acceptable threshold voltage shift and subthreshold hump effect. Depending on the simulation results, we believe that the electric field distribution in the STI oxide is the key parameter influencing bias effects on the radiation response of transistor. - Highlights: → ON bias is the worst bias condition for the ON, PASS and OFF bias modes. → Larger gate bias during irradiation leads to more pronounced characteristic degradation. → TID induced STI leakage can be suppressed by negative operating substrate bias voltage. → Negative substrate bias during irradiation leads to larger increase of off-state leakage. → Electric field in the STI oxide greatly influences the device's radiation effect.

  13. Evaluation of Total Daily Dose and Glycemic Control for Patients on U-500 Insulin Admitted to the Hospital

    Science.gov (United States)

    2016-05-20

    regular insulin has significantly increased in recent years. These patients are severely insulin resistant requiring high doses of insulin to achieve...on U-500 Insulin Admitted to the Hospital presented at SURF Conference, San Antonio, TX 20 May 201 6 with MDWI 41-108, and has been assigned local...59th CSPG/SGVU) C.201 4 . I 52d PROTOCOL TITLE Evaluation of Total Dai ly Dose and Glycemic Control for Patients on U-500 Insulin Admitted to the

  14. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    International Nuclear Information System (INIS)

    Lucero, J. F.; Rojas, J. I.

    2016-01-01

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  15. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    Energy Technology Data Exchange (ETDEWEB)

    Lucero, J. F., E-mail: fernando.lucero@hoperadiotherapy.com.gt [Universidad Nacional de Costa Rica, Heredia (Costa Rica); Hope International, Guatemala (Guatemala); Rojas, J. I., E-mail: isaac.rojas@siglo21.cr [Centro Médico Radioterapia Siglo XXI, San José (Costa Rica)

    2016-07-07

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  16. Clinical responses after total body irradiation by over permissible dose of γ-rays in one time

    International Nuclear Information System (INIS)

    Jiang Benrong; Wang Guilin; Liu Huilan; Tang Xingsheng; Ai Huisheng

    1990-01-01

    The clinical responses of patients after total body over permissilbe dose γ-ray irradiation were observed and analysed. The results showed: when the dose was above 5 cGy, there was some immunological depression, but no significant change in hematopoietic functions. 5 cases showed some transient changes of ECG, perhaps due to vagotonia caused by psychological imbalance, One case vomitted 3-4 times after 28 cGy irradiation, this suggested that a few times of vomitting had no significance in the estimation of the irradiated dose and the whole clinical manifestations must be concretely analysed

  17. Fast method for in-flight estimation of total dose from protons and electrons using RADE Minstrument on JUICE

    Science.gov (United States)

    Hajdas, Wojtek; Mrigakshi, Alankrita; Xiao, Hualin

    2017-04-01

    The primary concern of the ESA JUICE mission to Jupiter is the harsh particle radiation environment. Ionizing particles introduce radiation damage by total dose effects, displacement damages or single events effects. Therefore, both the total ionizing dose and the displacement damage equivalent fluence must be assessed to alert spacecraft and its payload as well as to quantify radiation levels for the entire mission lifetime. We present a concept and implementations steps for simplified method used to compute in flight a dose rate and total dose caused by protons. We also provide refinement of the method previously developed for electrons. The dose rates values are given for predefined active volumes located behind layers of materials with known thickness. Both methods are based on the electron and proton flux measurements provided by the Electron and Proton Detectors inside the Radiation Hard Electron Monitor (RADEM) located on-board of JUICE. The trade-off between method accuracy and programming limitations for in-flight computations are discussed. More comprehensive and precise dose rate computations based on detailed analysis of all stack detectors will be made during off-line data processing. It will utilize full spectral unfolding from all RADEM detector subsystems.

  18. High-dose total-body irradiation and autologous marrow reconstitution in dogs: dose-rate-related acute toxicity and fractionation-dependent long-term survival

    International Nuclear Information System (INIS)

    Deeg, H.J.; Storb, R.; Weiden, P.L.; Schumacher, D.; Shulman, H.; Graham, T.; Thomas, E.D.

    1981-01-01

    Beagle dogs treated by total-body irradiation (TBI) were given autologous marrow grafts in order to avoid death from marrow toxicity. Acute and delayed non-marrow toxicities of high single-dose (27 dogs) and fractionated TBI (20 dogs) delivered at 0.05 or 0.1 Gy/min were compared. Fractionated TBI was given in increments of 2 Gy every 6 hr for three increments per day. Acute toxicity and early mortality (<1 month) at identical total irradiation doses were comparable for dogs given fractionated or single-dose TBI. With single-dose TBI, 14, 16, and 18 Gy, respectively, given at 0.05 Gy/min, 0/5, 5/5, and 2/2 dogs died from acute toxicity; with 10, 12, and 14 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 5/5 dogs died acutely. With fractionated TBI, 14 and 16 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 2/2 dogs died auctely. Early deaths were due to radiation enteritis with or without associated septicemia (29 dogs; less than or equal to Day 10). Three dogs given 10 Gy of TBI at 0.1 Gy/min died from bacterial pneumonia; one (Day 18) had been given fractionated and two (Days 14, 22) single-dose TBI. Fifteen dogs survived beyond 1 month; eight of these had single-dose TBI (10-14 Gy) and all died within 7 months of irradiation from a syndrome consisting of hepatic damage, pancreatic fibrosis, malnutrition, wasting, and anemia. Seven of the 15 had fractionated TBI, and only one (14 Gy) died on Day 33 from hepatic failure, whereas 6 (10-14 Gy) are alive and well 250 to 500 days after irradiation. In conclusion, fractionated TBI did not offer advantages over single-dose TBI with regard to acute toxicity and early mortality; rather, these were dependent upon the total dose of TBI. The total acutely tolerated dose was dependent upon the exposure rate; however, only dogs given fractionated TBI became healthy long-term survivors

  19. Specialist pediatric palliative care prescribing practices: A large 5-year retrospective audit

    Directory of Open Access Journals (Sweden)

    Anuja Damani

    2016-01-01

    Full Text Available Introduction: There is a gradual increasing trend in childhood cancers in India and pediatric palliative care in India is an emerging specialty. Prescribing pain and symptom control drugs in children with cancer requires knowledge of palliative care formulary, dosing schedules, and prescription guidelines. This study is a retrospective audit of prescribing practices of a specialist palliative care service situated in a tertiary cancer center. Methods: A total of 1135 medication records of children receiving specialist pediatric palliative care services were audited for 5 years (2010-2014 to evaluate prescribing practices in children with advanced cancer. Results: A total of 51 types of drugs were prescribed with an average of 4.2 drugs per prescription. 66.9% of the prescriptions had paracetamol, and 33.9% of the prescriptions had morphine. Most common nonsteroidal anti-inflammatory drugs prescribed was ibuprofen (23.9%, and more than 50% of the prescriptions had aperients. The most commonly prescribed aperient was a combination of liquid paraffin and sodium-picosulfate. Dexamethasone was prescribed in 51.9% of patients and in most cases this was part of oral chemotherapy regimen. Generic names in prescription were used only in 33% of cases, and adverse effects of the drugs were documented in only 9% of cases. In 25% of cases, noncompliance to the WHO prescription guidelines was seen, and patient compliance to prescription was seen in 40% of cases. Conclusions: Audit of the prescribing practices in specialist pediatric palliative care service shows that knowledge of pediatric palliative care formulary, rational drug use, dosing, and prescribing guidelines is essential for symptom control in children with advanced life-limiting illness. Noncompliance to WHO prescribing guidelines in one fourth of cases and using nongeneric names in two-thirds of prescription indicates poor prescribing practices and warrants prescriber education. Prescription

  20. Three-dimensional Finite Elements Method simulation of Total Ionizing Dose in 22 nm bulk nFinFETs

    Energy Technology Data Exchange (ETDEWEB)

    Chatzikyriakou, Eleni, E-mail: ec3g12@soton.ac.uk; Potter, Kenneth; Redman-White, William; De Groot, C.H.

    2017-02-15

    Highlights: • Simulation of Total Ionizing Dose using the Finite Elements Method. • Carrier generation, transport and trapping in the oxide. • Application in three-dimensional bulk FinFET model of 22 nm node. • Examination of trapped charge in the Shallow Trench Isolation. • Trapped charge dependency of parasitic transistor current. - Abstract: Finite Elements Method simulation of Total Ionizing Dose effects on 22 nm bulk Fin Field Effect Transistor (FinFET) devices using the commercial software Synopsys Sentaurus TCAD is presented. The simulation parameters are extracted by calibrating the charge trapping model to experimental results on 400 nm SiO{sub 2} capacitors irradiated under zero bias. The FinFET device characteristics are calibrated to the Intel 22 nm bulk technology. Irradiation simulations of the transistor performed with all terminals unbiased reveal increased hardness up to a total dose of 1 MRad(SiO{sub 2}).

  1. Dose rate and total dose dependence of the 1/f noise performance of a GaAs operational amplifier during irradiation

    International Nuclear Information System (INIS)

    Hiemstra, D.M.

    1995-01-01

    A pictorial of a sectioned view of the torus of the International Thermonuclear Experimental Reactor (ITER) is shown. Maintenance and inspection of the reactor are required to be performed remotely. This is due to the high gamma radiation environment in vessel during inspection and maintenance activities. The custom GaAs operational amplifier is to be used to readout sensors on the in-vessel manipulator and inspection equipment. The gamma dose rate during maintenance and inspection is anticipated to be 3 Mrad(GaAs)/hour. Here, dose rate and total dose dependence of the 1/f noise performance of a custom GaAs MESFET operational amplifier during irradiation are presented. Dose rate dependent 1/f noise degradation during irradiation is believed to be due to electron trapping in deep levels, enhanced by backgating and shallow traps excited during irradiation. The reduction of this affect with accumulated total dose is believed to be due a reduction of deep level site concentration associated with substitutional oxygen. Post irradiation 1/f noise degradation is also presented.The generation-recombination noise observed post irradiation can be attributed to the production of shallow traps due to ionizing radiation

  2. Central axis dose verification in patients treated with total body irradiation of photons using a Computed Radiography system

    International Nuclear Information System (INIS)

    Rubio Rivero, A.; Caballero Pinelo, R.; Gonzalez Perez, Y.

    2015-01-01

    To propose and evaluate a method for the central axis dose verification in patients treated with total body irradiation (TBI) of photons using images obtained through a Computed Radiography (CR) system. It was used the Computed Radiography (Fuji) portal imaging cassette readings and correlate with measured of absorbed dose in water using 10 x 10 irradiation fields with ionization chamber in the 60 Co equipment. The analytical and graphic expression is obtained through software 'Origin8', the TBI patient portal verification images were processed using software ImageJ, to obtain the patient dose. To validate the results, the absorbed dose in RW3 models was measured with ionization chamber with different thickness, simulating TBI real conditions. Finally it was performed a retrospective study over the last 4 years obtaining the patients absorbed dose based on the reading in the image and comparing with the planned dose. The analytical equation obtained permits estimate the absorbed dose using image pixel value and the dose measured with ionization chamber and correlated with patient clinical records. Those results are compared with reported evidence obtaining a difference less than 02%, the 3 methods were compared and the results are within 10%. (Author)

  3. Design of spray dried insulin microparticles to bypass deposition in the extrathoracic region and maximize total lung dose.

    Science.gov (United States)

    Ung, Keith T; Rao, Nagaraja; Weers, Jeffry G; Huang, Daniel; Chan, Hak-Kim

    2016-09-25

    Inhaled drugs all too often deliver only a fraction of the emitted dose to the target lung site due to deposition in the extrathoracic region (i.e., mouth and throat), which can lead to increased variation in lung exposure, and in some instances increases in local and systemic side effects. For aerosol medications, improved targeting to the lungs may be achieved by tailoring the micromeritic properties of the particles (e.g., size, density, rugosity) to minimize deposition in the mouth-throat and maximize the total lung dose. This study evaluated a co-solvent spray drying approach to modulate particle morphology and dose delivery characteristics of engineered powder formulations of insulin microparticles. The binary co-solvent system studied included water as the primary solvent mixed with an organic co-solvent, e.g., ethanol. Factors such as the relative rate of evaporation of each component of a binary co-solvent mixture, and insulin solubility in each component were considered in selecting feedstock compositions. A water-ethanol co-solvent mixture with a composition range considered suitable for modulating particle shell formation during drying was selected for experimental investigation. An Alberta Idealized Throat model was used to evaluate the in vitro total lung dose of a series of spray dried insulin formulations engineered with different bulk powder properties and delivered with two prototype inhalers that fluidize and disperse powder using different principles. The in vitro total lung dose of insulin microparticles was improved and favored for powders with low bulk density and small primary particle size, with reduction of deposition in the extrathoracic region. The results demonstrated that a total lung dose >95% of the delivered dose can be achieved with engineered particles, indicating a high degree of lung targeting, almost completely bypassing deposition in the mouth-throat. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Assessment of antibiotic prescribing in Latvian general practitioners

    Directory of Open Access Journals (Sweden)

    Dumpis Uga

    2013-01-01

    Full Text Available Abstract Background Though general antibiotic consumption data is available, information on the actual patterns of prescribing antibiotics locally is difficult to obtain. An easy to use methodology was designed to assess ambulatory management of infections by Latvian general practitioners (GPs. Methods GPs were asked to record data in a patient data collection form for every patient that received antibiotics. Study period – (7 days one week in November, 2008. Data recorded included the following details: an antibiotic, the prescribed dose, dosing interval, route of administration combined with the demographic factors of the patient and clinical diagnosis based on a pre-defined list. Results Two hundred forty eight forms out of the 600 (41% were returned by post. Antibiotics were prescribed in 6.4% (1711/26803 of outpatient consultations. In total, 1763 antibiotics were prescribed during the study period. Ninety seven percent of the patients received monotherapy and only 47 (2.7% patients were prescribed two antibiotics. The most commonly prescribed antibiotics were amoxicillin (33.9% of prescribed, amoxicillin/clavulanate (18,7% and clarithromycin (7.6%. The most commonly treated indications were pharyngitis (29.8%, acute bronchitis (25.3% and rhinosinusitis (10.2%. Pneumonia was mostly treated with amoxicillin/clavulanate (25,7%, amoxicillin (15.7% and clarithromycin (19.3%. Conclusions Methodology employed provided useful additional information on ambulatory practice of prescribing antibiotics and could be used in further assessment studies. Educational interventions should be focused on treatment of acute pharyngitis and bronchitis in children and unnecessary use of quinolones in adults for uncomplicated urinary tract infection.

  5. Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study

    Science.gov (United States)

    Chen, Yingxuan; Yin, Fang-Fang; Zhang, Yawei; Zhang, You; Ren, Lei

    2018-04-01

    Purpose: compressed sensing reconstruction using total variation (TV) tends to over-smooth the edge information by uniformly penalizing the image gradient. The goal of this study is to develop a novel prior contour based TV (PCTV) method to enhance the edge information in compressed sensing reconstruction for CBCT. Methods: the edge information is extracted from prior planning-CT via edge detection. Prior CT is first registered with on-board CBCT reconstructed with TV method through rigid or deformable registration. The edge contours in prior-CT is then mapped to CBCT and used as the weight map for TV regularization to enhance edge information in CBCT reconstruction. The PCTV method was evaluated using extended-cardiac-torso (XCAT) phantom, physical CatPhan phantom and brain patient data. Results were compared with both TV and edge preserving TV (EPTV) methods which are commonly used for limited projection CBCT reconstruction. Relative error was used to calculate pixel value difference and edge cross correlation was defined as the similarity of edge information between reconstructed images and ground truth in the quantitative evaluation. Results: compared to TV and EPTV, PCTV enhanced the edge information of bone, lung vessels and tumor in XCAT reconstruction and complex bony structures in brain patient CBCT. In XCAT study using 45 half-fan CBCT projections, compared with ground truth, relative errors were 1.5%, 0.7% and 0.3% and edge cross correlations were 0.66, 0.72 and 0.78 for TV, EPTV and PCTV, respectively. PCTV is more robust to the projection number reduction. Edge enhancement was reduced slightly with noisy projections but PCTV was still superior to other methods. PCTV can maintain resolution while reducing the noise in the low mAs CatPhan reconstruction. Low contrast edges were preserved better with PCTV compared with TV and EPTV. Conclusion: PCTV preserved edge information as well as reduced streak artifacts and noise in low dose CBCT reconstruction

  6. Application of a Pelletron accelerator to study total dose radiation effects on 50 GHz SiGe HBTs

    Energy Technology Data Exchange (ETDEWEB)

    Praveen, K.C.; Pushpa, N.; Naik, P.S. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570 006 (India); Cressler, John D. [School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA (United States); Tripathi, Ambuj [Inter University Accelerator Centre (IUAC), New Delhi 110 067 (India); Gnana Prakash, A.P., E-mail: gnanaprakash@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570 006 (India)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer Total dose effects of 50 MeV Li3+ ion on 50 GHz SiGe HBTs is investigated. Black-Right-Pointing-Pointer Ion irradiated results were compared with Co-60 gamma results. Black-Right-Pointing-Pointer 50 MeV Li ions create more damage in E-B spacer oxide when compared to Co-60 gamma radiation. Black-Right-Pointing-Pointer Co-60 gamma radiation create more damage in STI oxide when compared to 50 MeV Li ions. Black-Right-Pointing-Pointer Worst case total dose radiation effects can be studied using Pelletron accelerator facilities. - Abstract: We have investigated the effects of 50 MeV lithium ion irradiation on the DC electrical characteristics of first-generation silicon-germanium heterojunction bipolar transistors (50 GHz SiGe HBTs) in the dose range of 600 krad to 100 Mrad. The results of 50 MeV Li{sup 3+} ion irradiation on the SiGe HBTs are compared with 63 MeV proton and Co-60 gamma irradiation results in the same dose range in order to understand the damage induced by different LET species. The radiation response of emitter-base (EB) spacer oxide and shallow trench isolation (STI) oxide to different irradiation types are discussed in this paper. We have also focused on the efficacy in the application of a Pelletron accelerator to study total dose irradiation studies in SiGe HBTs.

  7. Intralesional Versus Oral Chloroquine in Cutaneous Leishmaniasis: Comparison of Outcome, Duration of Treatment and Total Dose of Drug

    International Nuclear Information System (INIS)

    Hanif, M. M.; Akram, K.; Mustafa, G.

    2016-01-01

    Objective: To compare intralesional versus oral chloroquine in cutaneous leishmaniasis and determine the cure rate, duration of treatment, and total dose of drug. Study Design: Randomized controlled study. Place and Duration of Study: Department of Dermatology, Sheikh Zayed Medical College/Hospital, Rahim Yar Khan, from November 2013 to June 2014. Methodology: Consecutive 86 patients of cutaneous leishmaniasis, with single to multiple lesions of various sizes were enrolled and divided randomly into group A and B for the purpose of intralesional and oral chloroquine administration, respectively to compare the effect of the two routes on duration of treatment and total dose of the drug. SPSS version 16 was used for data analysis after data entry into it. Quantitative variables like, duration, cost and total dose of treatment were calculated as mean and standard deviation and compared by using T-test. P-value of less than 0.05 was taken as significant. Results: Cure rate was 100% in both groups towards the end of treatment. Mean duration of treatment was 9.17 ± 3 weeks in intralesional (A) group as against 11.37 ± 3 weeks in oral (B) group (p = 0.0028). Mean total dose of the drug given to each patient in group A was 5.8 ± 0.5 gm and in group B, it was 19.2 ± 1.5 gm, which is significantly higher (p=0.001). The total cost of treatment in group A was Rs. 90 ± 8 and in group B it was Rs. 91 ± 1 (p=0.446). Conclusion: Duration of treatment is significantly shorter and total dose is lesser with intralesional compared to oral chloroquine in treatment of cutaneous leishmaniasis. (author)

  8. 85Kr management trade-offs: a perspective to total radiation dose commitment

    International Nuclear Information System (INIS)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for 85 Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether 85 Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person

  9. 85Kr management trade-offs: a perspective to total radiation dose commitment

    Energy Technology Data Exchange (ETDEWEB)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for /sup 85/Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether /sup 85/Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person (<0.001% of natural background radiation for the same time period).

  10. Recent advances in understanding total-dose effects in bipolar transistors

    International Nuclear Information System (INIS)

    Schrimpf, R.D.

    1996-01-01

    Gain degradation in irradiated bipolar transistors can be a significant problem, particularly in linear integrated circuits. In many bipolar technologies, the degradation is greater for irradiation at low dose rates than it is for typical laboratory dose rates. Ionizing radiation causes the base current in bipolar transistors to increase, due to the presence of net positive charge in the oxides covering sensitive device areas and increases in surface recombination velocity. Understanding the mechanisms responsible for radiation-induced gain degradation in bipolar transistors is important in developing appropriate hardness assurance methods. This paper reviews recent modeling and experimental work, with the emphasis on low-dose-rate effects. A promising hardness assurance method based on irradiation at elevated temperatures is described

  11. Serum level modifications of female sex hormones after radiocastration with different total doses

    International Nuclear Information System (INIS)

    Naujokat, B.; Rohloff, R.; Willich, N.; Eiermann, W.

    1988-01-01

    We determined serum level of estradiol, FSH and LH over a period of six to eight weeks after ovarian irradiation for castration with different doses (2x2.5 Gy/3x2.5 Gy/4x2.5 Gy) in 15 patients with metastatic breast cancer as compared to changes after ovarectomy in five patients. The time course of the changing estradiol-, FSH and LH-serum levels sigificantly depends on the ovarian dose. After radiological castration with a dose of 4x2.5 Gy = 10 Gy in four days the estrogen levels decrease within two to three weeks, and the FSH- and LH-levels increase after three to four weeks into the postmenopausal range. Therefore, the time course is not very different from changes after ovarectomy. (orig.) [de

  12. A prospective, open-label study of low-dose total skin electron beam therapy in mycosis fungoides

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Specht, Lena; Skovgaard, Gunhild L

    2008-01-01

    causes and did not complete treatment. Acute side effects included desquamation, xerosis, and erythema of the skin. No severe side effects were observed. CONCLUSION: Low-dose total skin electron beam therapy can induce complete and partial responses in Stage IB-II mycosis fungoides; however, the duration......PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years......]) with histopathologically confirmed mycosis fungoides T2-T4 N0-N1 M0 who did not achieve complete remission or relapsed within 4 months after treatment with psoralen plus ultraviolet-A were included. Treatment consisted of low-dose total skin electron beam therapy administered at a total skin dose of 4 Gy given in 4...

  13. Cumulative total effective whole-body radiation dose in critically ill patients.

    Science.gov (United States)

    Rohner, Deborah J; Bennett, Suzanne; Samaratunga, Chandrasiri; Jewell, Elizabeth S; Smith, Jeffrey P; Gaskill-Shipley, Mary; Lisco, Steven J

    2013-11-01

    Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.

  14. The effects of dose rate in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Bodenberger, U.; Holler, E.; Thierfelder, S.; Eckstein, R.

    1986-01-01

    In summary the studies in dogs show that the dose rate or exposure time has a great impact on survival of acute radiation syndromes. In contrast the inactivation of colony forming hemopoietic precursors is less influenced by the dose rate. The potential of hemopoietic recovery is determined by the survival of hemopoietic precursor cells. Therefore in patients with a suspected whole body exposure of more than 1.50 Gy, bacterial and fungal decontamination and reverse isolation in a sterile environment has to be started immediately. Human patients treated with about 10 Gy of TBI frequently developed nausea, elevated temperatures and swelling of the parotic glands at the first and second day. The extent of these changes varies from patient to patient. The temperature is rarely elevated above 38.5 0 C. The swelling of parotics and the nausea subside within 48 hours. The presence of such systemic symptoms may suggest the exposure to a lethal dose of radiation. The disappearance of immature red cells, i.e. reticulocytes, and bandforms of granulocytes within the first 5 days supports this suggestion. HLA typing of the victim and his family should be performed as soon as possible after the accident. An HLA-identical sibling would be a suitable bone marrow donor. Unlike therapeutic TBI accidental exposures bring about uncertainties in the calculation of dose, dose distribution and dose rate. Early after irradiation biological changes are extremely variable. Both biological and physical data have to be considered, when microbiological decontamination, reverse isolation and transplantation of bone marrow are to be decided upon. Obviously these intensive therapeutic efforts are limited to a small number of victims. (orig.)

  15. Prediction of total dose effects on sub-micron process metal oxide semiconductor devices

    International Nuclear Information System (INIS)

    Kamimura, Hiroshi; Kato, Masataka.

    1991-01-01

    A method for correcting leakage currents is described to predict the radiation-induced threshold voltage shift of sub-micron MOSFETs. A practical model for predicting the leakage current generated by irradiation is also given on the basis of experimental results on 0.8-μm process MOSFETs. The constants in the threshold voltage shift model are determined from the 'true' I-V characteristic of the MOSFET, which is obtained by correction of leakage currents due to characteristic change of a parasitic transistor. In this way, the threshold voltage shift of the n-channel MOSFET irradiated at a low dose rate of 2 Gy(Si)/h was also calculated by using data from a high dose rate irradiation experiment (100 Gy(Si)/h, 5 h). The calculated result well represented the tendency of measured data on threshold voltage shift. The radiation-induced leakage current was considered to decay approximately in two exponential modes. The constants in this leakage current model were determined from the above high dose rate experiment. The response of leakage current predicted at a low dose rate of 2 Gy(Si)/h approximately agreed with that measured during and after irradiation. (author)

  16. Total dose effects on elementary transistors of a comparator in bipolar technology

    International Nuclear Information System (INIS)

    Sarrabayrouse, G.; Guerre, F.X.

    1995-01-01

    In the present work we investigate elementary transistors behaviour of an Integrated Circuit using junction isolation bipolar technology. Polarization conditions and dose rate effects on the main elementary transistor types are analysed. Furthermore, the IC electronic function degradations are studied. Finally, a comparison between the function degradations and the elementary component ones is attempted. (author)

  17. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  18. Total Ionizing Dose Effects on Threshold Switching in 1T-Tantalum Disulfide Charge-Density-Wave Devices

    OpenAIRE

    Liu, G.; Zhang, E. X.; Liang, C. D.; Bloodgood, M. A.; Salguero, T. T.; Fleetwood, D. M.; Balandin, A. A.

    2017-01-01

    The 1T polytype of TaS2 exhibits voltage-triggered threshold switching as a result of a phase transition from nearly commensurate to incommensurate charge density wave states. Threshold switching, persistent above room temperature, can be utilized in a variety of electronic devices, e.g., voltage controlled oscillators. We evaluated the total-ionizing-dose response of thin film 1T-TaS2 at doses up to 1 Mrad(SiO2). The threshold voltage changed by less than 2% after irradiation, with persisten...

  19. High total dose proton irradiation effects on silicon NPN rf power transistors

    International Nuclear Information System (INIS)

    Bharathi, M. N.; Praveen, K. C.; Prakash, A. P. Gnana; Pushpa, N.

    2014-01-01

    The effects of 3 MeV proton irradiation on the I-V characteristics of NPN rf power transistors were studied in the dose range of 100 Krad to 100 Mrad. The different electrical characteristics like Gummel, current gain and output characteristics were systematically studied before and after irradiation. The recovery in the I-V characteristics of irradiated NPN BJTs were studied by isochronal and isothermal annealing methods

  20. High total dose proton irradiation effects on silicon NPN rf power transistors

    Energy Technology Data Exchange (ETDEWEB)

    Bharathi, M. N.; Praveen, K. C.; Prakash, A. P. Gnana, E-mail: gnanaprakash@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore-570006, Karnataka (India); Pushpa, N. [Department of PG Studies in Physics, JSS College, Ooty Road, Mysore-570025, Karnataka (India)

    2014-04-24

    The effects of 3 MeV proton irradiation on the I-V characteristics of NPN rf power transistors were studied in the dose range of 100 Krad to 100 Mrad. The different electrical characteristics like Gummel, current gain and output characteristics were systematically studied before and after irradiation. The recovery in the I-V characteristics of irradiated NPN BJTs were studied by isochronal and isothermal annealing methods.

  1. Impact of total radiotherapy dose on survival for head and neck Merkel cell carcinoma after resection.

    Science.gov (United States)

    Patel, Sagar A; Qureshi, Muhammad M; Mak, Kimberley S; Sahni, Debjani; Giacalone, Nicholas J; Ezzat, Waleed; Jalisi, Scharukh; Truong, Minh Tam

    2017-07-01

    Head and neck Merkel cell carcinoma (MCC) is commonly treated with surgery and adjuvant radiotherapy (RT) for high-risk features. The optimal radiation dose is unknown. One thousand six hundred twenty-five eligible patients with head and neck MCC were identified in the National Cancer Data Base (NCDB). Radiation dose was divided into 3 groups: 30 to 55-70 Gy. Cox regression was used to compare overall survival (OS) between groups, accounting for age, sex, stage, surgery type, margin status, comorbidities, and use of chemotherapy. With a median follow-up of 33.5 months, 3-year OS was 48.9%, 70.3%, and 58.7% for 30 to 55-70 Gy, respectively (P 55-70 Gy (adjusted HR 1.21; 95% CI 1.0-1.46; P = .06) were associated with worse survival. Adjuvant radiation doses within 50-55 Gy may be optimal for head and neck MCC. © 2017 Wiley Periodicals, Inc.

  2. Using a computerized provider order entry system to meet the unique prescribing needs of children: description of an advanced dosing model

    Directory of Open Access Journals (Sweden)

    Schellenberger Patricia

    2011-02-01

    Full Text Available Abstract Background It is well known that the information requirements necessary to safely treat children with therapeutic medications cannot be met with the same approaches used in adults. Over a 1-year period, Duke University Hospital engaged in the challenging task of enhancing an established computerized provider order entry (CPOE system to address the unique medication dosing needs of pediatric patients. Methods An advanced dosing model (ADM was designed to interact with our existing CPOE application to provide decision support enabling complex pediatric dose calculations based on chronological age, gestational age, weight, care area in the hospital, indication, and level of renal impairment. Given that weight is a critical component of medication dosing that may change over time, alerting logic was added to guard against erroneous entry or outdated weight information. Results Pediatric CPOE was deployed in a staggered fashion across 6 care areas over a 14-month period. Safeguards to prevent miskeyed values became important in allowing providers the flexibility to override the ADM logic if desired. Methods to guard against over- and under-dosing were added. The modular nature of our model allows us to easily add new dosing scenarios for specialized populations as the pediatric population and formulary change over time. Conclusions The medical needs of pediatric patients vary greatly from those of adults, and the information systems that support those needs require tailored approaches to design and implementation. When a single CPOE system is used for both adults and pediatrics, safeguards such as redirection and suppression must be used to protect children from inappropriate adult medication dosing content. Unlike other pediatric dosing systems, our model provides active dosing assistance and dosing process management, not just static dosing advice.

  3. Should patients prescribed long-term low-dose aspirin receive proton pump inhibitors? A systematic review and meta-analysis

    NARCIS (Netherlands)

    Tran-Duy, A.; Vanmolkot, F. H.; Joore, M. A.; Hoes, A. W.; Stehouwer, C. D. A.

    2015-01-01

    Background: Several clinical guidelines recommend the use of proton pump inhibitors (PPIs) in patients taking low-dose aspirin but report no or limited supporting data. We conducted a systematic review and meta-analysis to examine the effects of co-administration of PPIs in patients taking low-dose

  4. Concentration of total proteins in blood plasma of chickens hatched from irradiated eggs with low dose gamma radiation

    International Nuclear Information System (INIS)

    Vilic, M.; Kraljevic, P.; Miljanic, S.; Simpraga, M.

    2005-01-01

    It is known that low-dose ionising radiation may have stimulating effects on chickens. Low doses may also cause changes in the concentration of blood plasma total proteins, glucose and cholesterol in chickens. This study investigates the effects of low dose gamma-radiation on the concentration of total proteins in the blood plasma of chickens hatched from eggs irradiated with a dose of 0.15 Gy on incubation days 7 and 19. Results were compared with the control group (chickens hatched from non-irradiated eggs). After hatching, all other conditions were the same for both groups. Blood samples were drawn from the heart, and later from the wing vein on days 1, 3, 5, 7,10, 20, 30 and 42. The concentration of total proteins was determined spectrophotometrically using Boehringer Mannheim GmbH optimised kits. The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 7 showed a statistically significant decrease on the sampling day 3 (P less than 0.05) and 7 (P less than 0.01). The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 19 showed a statistically significant increase only on sampling day 1 (P less than 0.05). These results suggest that exposure of eggs to 0.15 Gy of gamma-radiation on the 7th and 19th day of incubation could produce different effects on the protein metabolism in chickens.(author)

  5. Low Dose Gamma Irradiation Does Not Affect the Quality or Total Ascorbic Acid Concentration of "Sweetheart" Passionfruit (Passiflora edulis).

    Science.gov (United States)

    Golding, John B; Blades, Barbara L; Satyan, Shashirekha; Spohr, Lorraine J; Harris, Anne; Jessup, Andrew J; Archer, John R; Davies, Justin B; Banos, Connie

    2015-08-26

    Passionfruit ( Passiflora edulis , Sims, cultivar "Sweetheart") were subject to gamma irradiation at levels suitable for phytosanitary purposes (0, 150, 400 and 1000 Gy) then stored at 8 °C and assessed for fruit quality and total ascorbic acid concentration after one and fourteen days. Irradiation at any dose (≤1000 Gy) did not affect passionfruit quality (overall fruit quality, colour, firmness, fruit shrivel, stem condition, weight loss, total soluble solids level (TSS), titratable acidity (TA) level, TSS/TA ratio, juice pH and rot development), nor the total ascorbic acid concentration. The length of time in storage affected some fruit quality parameters and total ascorbic acid concentration, with longer storage periods resulting in lower quality fruit and lower total ascorbic acid concentration, irrespective of irradiation. There was no interaction between irradiation treatment and storage time, indicating that irradiation did not influence the effect of storage on passionfruit quality. The results showed that the application of 150, 400 and 1000 Gy gamma irradiation to "Sweetheart" purple passionfruit did not produce any deleterious effects on fruit quality or total ascorbic acid concentration during cold storage, thus supporting the use of low dose irradiation as a phytosanitary treatment against quarantine pests in purple passionfruit.

  6. Radiobiological basis of total body irradiation with different dose rate and fractionation: repair capacity of hemopoietic cells

    International Nuclear Information System (INIS)

    Song, C.W.; Kim, T.H.; Khan, F.M.; Kersey, J.H.; Levitt, S.H.

    1981-01-01

    Total body irradiation (TBI) followed by bone marrow transplantation is being used in the treatment of malignant or non-malignant hemopoietic disorders. It has been believed that the ability of hemopoietic cells to repair sublethal radiation damage is negligible. Therefore, several schools of investigators suggested that TBI in a single exposure at extremely low dose rate (5 rad/min) over several hours, or in several fractions in 2-3 days, should yield a higher therapeutic gain, as compared with a single exposure at a high dose rate (26 rad/min). We reviewed the existing data in the literature, in particular, the response of hemopoietic cells to fractionated doses of irradiation and found that the repair capacity of both malignant and non-malignant hemopoietic cells might be greater than has been thought. It is concluded that we should not underestimate the ability of hemopoietic cells to repair sublethal radiation damage in using TBI

  7. Total and single doses influence the effectiveness of radiotherapy in palliative treatment of plasmacytoma

    Energy Technology Data Exchange (ETDEWEB)

    Stoelting, T.; Knauerhase, H.; Klautke, G. [Dept. of Radiotherapy, Univ. of Rostock (Germany); Kundt, G. [Inst. for Medical Informatics and Biometry, Univ. of Rostock (Germany); Fietkau, R. [Dept. of Radiotherapy, Univ. of Rostock (Germany); Dept. of Radiotherapy, Univ. of Erlangen (Germany)

    2008-09-15

    Purpose: in a retrospective analysis of radiotherapy of plasmacytomas, the effectiveness and the prognostic factors in regard to pain reduction and recalcification were evaluated. Patients and methods: 138 patients (70 women, 68 men; 15-86 years, median 61 years) were irradiated at 272 target volumes (TVs) from January 1970 to December 2003. Results: in 192/225 TVs (85.3%), there was a pain reduction. The recalcification rate was 44.7% (51/114 TVs). Significant parameters for pain relief in the multivariate analysis were completeness of therapy (odds ratio [OR] 87.8; p < 0.001 vs. interruption), patients < 60 years (OR 23.0; p < 0.001 vs. {>=} 70 years), and a single dose of 2 Gy (OR 11.0; p = 0.027 vs. 4-15.0 Gy). Significant parameters for recalcification in the multivariate analysis were concurrent chemotherapy (OR 12.3; p < 0.001 vs. no chemotherapy), no fractures in the TV (OR 5.9; p < 0.004 vs. fracture), and a dose of 40-< 50 Gy (OR 21.9; p = 0.035 vs. < 30 Gy) or {>=} 50 Gy (OR 26.4; p = 0.033 vs. < 30 Gy). Conclusion: radiotherapy is a very effective palliative treatment. Patients with a reduced general condition, with multiple bone lesions and a poor prognosis profit from short-term schemes (e.g., 1 x 8 Gy to 10 x 3 Gy). Patients in good general condition with a life expectancy of > 1 year and an osteolysis at risk of fracture, should be treated with doses up to 40-50 Gy (20-25 x 2 Gy), in order to achieve the best possible recalcification and pain relief. (orig.)

  8. What do unsuccessful radiographs contribute to the total radiation dose to a patient

    International Nuclear Information System (INIS)

    Roth, J.; Nemec, H.W.

    1985-01-01

    Prevention of, or reduction of, unnecessary exposure to radiation is one of the prime goals of radiological protection in diagnostic radiology. The paper explains the advantages of a new approach, namely to achieve optimum focussing and adjustment of radiation sources for difficult imaging tasks by way of the fluoroscopic rather than the collimator method. The patient's exposure during this preliminary examination on the average will amount to 25 p.c. of the doses applied by the subsequent radiograph; on the other hand, this approach will reduce the number of unsuccessful pictures. (orig.) [de

  9. Total-dose radiation-induced degradation of thin film ferroelectric capacitors

    International Nuclear Information System (INIS)

    Schwank, J.R.; Nasby, R.D.; Miller, S.L.; Rodgers, M.S.; Dressendorfer, P.V.

    1990-01-01

    Thin film PbZr y Ti 1-y O 3 (PZT) ferroelectric memories offer the potential for radiation-hardened, high-speed nonvolatile memories with good retention and fatigue properties. In this paper we explore in detail the radiation hardness of PZT ferroelectric capacitors. Ferroelectric capacitors were irradiated using x-ray and Co-60 sources to dose levels up to 16 Mrad(Si). The capacitors were characterized for their memory properties both before and after irradiation. The radiation hardness was process dependent. Three out of four processes resulted in capacitors that showed less than 30% radiation-induced degradation in retained polarization charge and remanent polarization after irradiating to 16 Mrad(Si). On the other hand, one of the processes showed significant radiation-induced degradation in retained polarization charge and remanent polarization at dose levels above 1 Mrad(Si). The decrease in retained polarization charge appears to be due to an alteration of the switching characteristics of the ferroelectric due to changes in the internal fields. The radiation-induced degradation is recoverable by a postirradiation biased anneal and can be prevented entirely if devices are cycled during irradiation. The authors have developed a model to simulate the observed degradation

  10. Preliminary Radiation Analysis of the Total Ionizing Dose for the Resource Prospector Mission

    Science.gov (United States)

    Rojdev, Kristina; Tylka, Allan J.; Atwell, William

    2015-01-01

    NASA's Resource Prospector (RP) is a collaborative project between multiple centers and institutions to search for volatiles at the polar regions of the Moon as a potential resource for oxygen and propellant production. The mission is rated Class D and will be the first In-Situ Resource Utilization (ISRU) demonstration on the lunar surface and at the lunar poles. Given that this mission is rated Class D, the project is considering using commercial off the shelf (COTS) electronics parts to reduce cost. However, COTS parts can be more susceptible to space radiation than typical aerospace electronic parts and carry some additional risk. Thus, prior to parts selection, having a better understanding of the radiation environment can assist designers in the parts selection process. The focus of this paper is to provide a preliminary analysis of the radiation environment from launch, through landing on the surface, and some surface stay as an initial step in determining worst case mission doses to assist designers in screening out electronic parts that would not meet the potential dose levels experienced on this mission.

  11. Low-dose 4D cone-beam CT via joint spatiotemporal regularization of tensor framelet and nonlocal total variation

    Science.gov (United States)

    Han, Hao; Gao, Hao; Xing, Lei

    2017-08-01

    Excessive radiation exposure is still a major concern in 4D cone-beam computed tomography (4D-CBCT) due to its prolonged scanning duration. Radiation dose can be effectively reduced by either under-sampling the x-ray projections or reducing the x-ray flux. However, 4D-CBCT reconstruction under such low-dose protocols is prone to image artifacts and noise. In this work, we propose a novel joint regularization-based iterative reconstruction method for low-dose 4D-CBCT. To tackle the under-sampling problem, we employ spatiotemporal tensor framelet (STF) regularization to take advantage of the spatiotemporal coherence of the patient anatomy in 4D images. To simultaneously suppress the image noise caused by photon starvation, we also incorporate spatiotemporal nonlocal total variation (SNTV) regularization to make use of the nonlocal self-recursiveness of anatomical structures in the spatial and temporal domains. Under the joint STF-SNTV regularization, the proposed iterative reconstruction approach is evaluated first using two digital phantoms and then using physical experiment data in the low-dose context of both under-sampled and noisy projections. Compared with existing approaches via either STF or SNTV regularization alone, the presented hybrid approach achieves improved image quality, and is particularly effective for the reconstruction of low-dose 4D-CBCT data that are not only sparse but noisy.

  12. Effects on Ferroelectric Thin-Film Stacks and Devices for Piezoelectric MEMS Applications at Varied Total Ionizing Dose (TID)

    Science.gov (United States)

    2017-03-01

    non -linearly mobile internal interfaces, e.g. domain walls and eventual phase boundaries. Radiation exposure is expected...zirconate titanate; PZT; actuator; radiation ; gamma; total ionization dose; TID; top electrode; Pt; IrO2; polarization; PE; hysteresis; permittivity...Hayashigawa, et. al., “A 2 Mbit Radiation Hardened Stackable Ferroelectric Memory” Non - Volatile Memory Technology Symposium, NVMTS 07, Nov 10-13, 2007 Albuquerque, NM, USA

  13. Total and single doses influence the effectiveness of radiotherapy in palliative treatment of plasmacytoma

    International Nuclear Information System (INIS)

    Stoelting, T.; Knauerhase, H.; Klautke, G.; Kundt, G.; Fietkau, R.

    2008-01-01

    Purpose: in a retrospective analysis of radiotherapy of plasmacytomas, the effectiveness and the prognostic factors in regard to pain reduction and recalcification were evaluated. Patients and methods: 138 patients (70 women, 68 men; 15-86 years, median 61 years) were irradiated at 272 target volumes (TVs) from January 1970 to December 2003. Results: in 192/225 TVs (85.3%), there was a pain reduction. The recalcification rate was 44.7% (51/114 TVs). Significant parameters for pain relief in the multivariate analysis were completeness of therapy (odds ratio [OR] 87.8; p 1 year and an osteolysis at risk of fracture, should be treated with doses up to 40-50 Gy (20-25 x 2 Gy), in order to achieve the best possible recalcification and pain relief. (orig.)

  14. Models for Total-Dose Radiation Effects in Non-Volatile Memory

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Philip Montgomery; Wix, Steven D.

    2017-04-01

    The objective of this work is to develop models to predict radiation effects in non- volatile memory: flash memory and ferroelectric RAM. In flash memory experiments have found that the internal high-voltage generators (charge pumps) are the most sensitive to radiation damage. Models are presented for radiation effects in charge pumps that demonstrate the experimental results. Floating gate models are developed for the memory cell in two types of flash memory devices by Intel and Samsung. These models utilize Fowler-Nordheim tunneling and hot electron injection to charge and erase the floating gate. Erase times are calculated from the models and compared with experimental results for different radiation doses. FRAM is less sensitive to radiation than flash memory, but measurements show that above 100 Krad FRAM suffers from a large increase in leakage current. A model for this effect is developed which compares closely with the measurements.

  15. Effect of radiation dose rate and cyclophosphamide on pulmonary toxicity after total body irradiation in a mouse model

    International Nuclear Information System (INIS)

    Safwat, Akmal; Nielsen, Ole S.; El-Badawy, Samy; Overgaard, Jens

    1996-01-01

    Purpose: Interstitial pneumonitis (IP) is still a major complication after total body irradiation (TBI) and bone marrow transplantation (BMT). It is difficult to determine the exact role of radiation in this multifactorial complication, especially because most of the experimental work on lung damage was done using localized lung irradiation and not TBI. We have thus tested the effect of radiation dose rate and combining cyclophosphamide (CTX) with single fraction TBI on lung damage in a mouse model for BMT. Methods and Materials: TBI was given as a single fraction at a high dose rate (HDR, 0.71 Gy/min) or a low dose rate (LDR, 0.08 Gy/min). CTX (250 mg/kg) was given 24 h before TBI. Bone marrow transplantation (BMT) was performed 4-6 h after the last treatment. Lung damage was assessed using ventilation rate (VR) and lethality between 28 and 180 days (LD (50(28))-180 ). Results: The LD 50 for lung damage, ± standard error (SE), increased from 12.0 (± 0.2) Gy using single fraction HDR to 15.8 (± 0.6) Gy using LDR. Adding CTX shifted the dose-response curves towards lower doses. The LD 50 values for the combined treatment were 5.3 (± 0.2) and 3.5 (± 0.2) Gy for HDR and LDR, respectively. This indicates that the combined effect of CTX and LDR was more toxic than that of combined CTX and HDR. Lung damage evaluated by VR demonstrated two waves of VR increase. The first wave of VR increase occurred after 6 weeks using TBI only and after 3 weeks in the combined CTX-TBI treatment, irrespective of total dose or dose rate. The second wave of VR elevation resembled the IP that follows localized thoracic irradiation in its time of occurrence. Conclusions: Lung damage following TBI could be spared using LDR. However, CTX markedly enhances TBI-induced lung damage. The combination of CTX and LDR is more toxic to the lungs than combining CTX and HDR

  16. Low-dose dual-energy cone-beam CT using a total-variation minimization algorithm

    International Nuclear Information System (INIS)

    Min, Jong Hwan

    2011-02-01

    Dual-energy cone-beam CT is an important imaging modality in diagnostic applications, and may also find its use in other application such as therapeutic image guidance. Despite of its clinical values, relatively high radiation dose of dual-energy scan may pose a challenge to its wide use. In this work, we investigated a low-dose, pre-reconstruction type of dual-energy cone-beam CT (CBCT) using a total-variation minimization algorithm for image reconstruction. An empirical dual-energy calibration method was used to prepare material-specific projection data. Raw data at high and low tube voltages are converted into a set of basis functions which can be linearly combined to produce material-specific data using the coefficients obtained through the calibration process. From much fewer views than are conventionally used, material specific images are reconstructed by use of the total-variation minimization algorithm. An experimental study was performed to demonstrate the feasibility of the proposed method using a micro-CT system. We have reconstructed images of the phantoms from only 90 projections acquired at tube voltages of 40 kVp and 90 kVp each. Aluminum-only and acryl-only images were successfully decomposed. We evaluated the quality of the reconstructed images by use of contrast-to-noise ratio and detectability. A low-dose dual-energy CBCT can be realized via the proposed method by greatly reducing the number of projections

  17. Compendium of Single Event Effects, Total Ionizing Dose, and Displacement Damage for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    LaBel, Kenneth A.; OBryan, Martha V.; Chen, Dakai; Campola, Michael J.; Casey, Megan C.; Pellish, Jonathan A.; Lauenstein, Jean-Marie; Wilcox, Edward P.; Topper, Alyson D.; Ladbury, Raymond L.; hide

    2014-01-01

    We present results and analysis investigating the effects of radiation on a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects (SEE), proton-induced displacement damage (DD), and total ionizing dose (TID). Introduction: This paper is a summary of test results.NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment is often limited by its susceptibility to single event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is quite difficult. Given the rapidly changing nature of technology, radiation test data are most often application-specific and adequate understanding of the test conditions is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transient (SET), TID, enhanced low dose rate sensitivity (ELDRS), and DD effects.

  18. Dose-effect relationship for cataract induction after single-dose total body irradiation and bone marrow transplantation for acute leukemia

    International Nuclear Information System (INIS)

    Kempen-Harteveld, M. Loes van; Belkacemi, Yazid; Kal, Henk B.; Labopin, Myriam; Frassoni, Francesco

    2002-01-01

    Purpose: To determine a dose-effect relationship for cataract induction, the tissue-specific parameter, α/β, and the rate of repair of sublethal damage, μ value, in the linear-quadratic formula have to be known. To obtain these parameters for the human eye lens, a large series of patients treated with different doses and dose rates is required. The data of patients with acute leukemia treated with single-dose total body irradiation (STBI) and bone marrow transplantation (BMT) collected by the European Group for Blood and Marrow Transplantation were analyzed. Methods and Materials: The data of 495 patients who underwent BMT for acute leukemia, who had STBI as part of their conditioning regimen, were analyzed using the linear-quadratic concept. The end point was the incidence of cataract formation after BMT. Of the analyzed patients, 175 were registered as having cataracts. Biologic effective doses (BEDs) for different sets of values for α/β and μ were calculated for each patient. With Cox regression analysis, using the overall chi-square test as the parameter evaluating the goodness of fit, α/β and μ values were found. Risk factors for cataract induction were the BED of the applied TBI regimen, allogeneic BMT, steroid therapy for >14 weeks, and heparin administration. To avoid the influence of steroid therapy and heparin on cataract induction, patients who received steroid or heparin treatment were excluded, leaving only the BED as a risk factor. Next, the most likely set of α/β and μ values was obtained. With this set, the cataract-free survival rates were calculated for specific BED intervals, according to the Kaplan-Meier method. From these calculations, cataract incidences were obtained as function of the BED at 120 months after STBI. Results: The use of BED instead of the TBI dose enabled the incidence of cataract formation to be predicted in a reasonably consistent way. With Cox regression analysis for all STBI data, a maximal chi-square value was

  19. Dose Escalation of Total Marrow Irradiation With Concurrent Chemotherapy in Patients With Advanced Acute Leukemia Undergoing Allogeneic Hematopoietic Cell Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Jeffrey Y.C., E-mail: jwong@coh.org [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California (United States); Forman, Stephen; Somlo, George [Department of Hematology/Hematopoietic Cell Transplantation, City of Hope National Medical Center, Duarte, California (United States); Rosenthal, Joseph [Department of Hematology/Hematopoietic Cell Transplantation, City of Hope National Medical Center, Duarte, California (United States); Department of Pediatrics, City of Hope National Medical Center, Duarte, California (United States); Liu An; Schultheiss, Timothy; Radany, Eric [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California (United States); Palmer, Joycelynne [Department of Biostatistics, City of Hope National Medical Center, Duarte, California (United States); Stein, Anthony [Department of Hematology/Hematopoietic Cell Transplantation, City of Hope National Medical Center, Duarte, California (United States)

    2013-01-01

    Purpose: We have demonstrated that toxicities are acceptable with total marrow irradiation (TMI) at 16 Gy without chemotherapy or TMI at 12 Gy and the reduced intensity regimen of fludarabine/melphalan in patients undergoing hematopoietic cell transplantation (HCT). This article reports results of a study of TMI combined with higher intensity chemotherapy regimens in 2 phase I trials in patients with advanced acute myelogenous leukemia or acute lymphoblastic leukemia (AML/ALL) who would do poorly on standard intent-to-cure HCT regimens. Methods and Materials: Trial 1 consisted of TMI on Days -10 to -6, etoposide (VP16) on Day -5 (60 mg/kg), and cyclophosphamide (CY) on Day -3 (100 mg/kg). TMI dose was 12 (n=3 patients), 13.5 (n=3 patients), and 15 (n=6 patients) Gy at 1.5 Gy twice daily. Trial 2 consisted of busulfan (BU) on Days -12 to -8 (800 {mu}M min), TMI on Days -8 to -4, and VP16 on Day -3 (30 mg/kg). TMI dose was 12 (n=18) and 13.5 (n=2) Gy at 1.5 Gy twice daily. Results: Trial 1 had 12 patients with a median age of 33 years. Six patients had induction failures (IF), and 6 had first relapses (1RL), 9 with leukemia blast involvement of bone marrow ranging from 10%-98%, 5 with circulating blasts (24%-85%), and 2 with chloromas. No dose-limiting toxicities were observed. Eleven patients achieved complete remission at Day 30. With a median follow-up of 14.75 months, 5 patients remained in complete remission from 13.5-37.7 months. Trial 2 had 20 patients with a median age of 41 years. Thirteen patients had IF, and 5 had 1RL, 2 in second relapse, 19 with marrow blasts (3%-100%) and 13 with peripheral blasts (6%-63%). Grade 4 dose-limiting toxicities were seen at 13.5 Gy (stomatitis and hepatotoxicity). Stomatitis was the most frequent toxicity in both trials. Conclusions: TMI dose escalation to 15 Gy is possible when combined with CY/VP16 and is associated with acceptable toxicities and encouraging outcomes. TMI dose escalation is not possible with BU/VP16 due to

  20. Effect of prescribing a high protein diet and increasing the dose of dialysis on nutrition in stable chronic haemodialysis patients : a randomized, controlled trial

    NARCIS (Netherlands)

    Kloppenburg, Wybe; Stegeman, CA; Kremer Hovinga, T; Vastenburg, G; Vos, P; de Jong, PE; Huisman, RM

    Background. Protein requirements in stable, adequately dialysed haemodialysis patients are not known and recommendations vary. It is not known whether increasing the dialysis dose above the accepted adequate level has a favourable effect on nutrition. The aim of this study was to determine whether

  1. Single dose total lymphoid irradiation combined with cyclophosphamide as immunosuppression for human marrow transplantation in aplastic anemia

    International Nuclear Information System (INIS)

    Kim, T.H.; Kersey, J.H.; Khan, F.M.; Sewchand, W.; Ramsey, N.; Krivit, W.; Coccia, P.; Nesbit, M.E.; Levitt, S.H.

    1979-01-01

    Six patients with aplastic anemia underwent bone marrow transplantation following conditioning with high dose cyclophosphamide and single dose total lymphoid irradiation with 750 rad, 26 rad/min at the midplane of the patient. They all received bone marrow from human leukocyte antigens/mixed lymphocyte culture (HLA/MLC) matched siblings. Five of 6 patients were alive without complications at 12, 11, 7, 4 and 4 months respectively. The remaining patient died from sepis which he had prior to transplantation. There were no graft rejection, graft-vs-Host Disease (GVHD) or interstitial pneumonitis among these patients. The procedure was well tolerated with minimal side effects. The results will be compared with those of groups whose bone marrow was previously transplanted with different immunosuppressive methods

  2. Enrichment increases hippocampal neurogenesis independent of blood monocyte-derived microglia presence following high-dose total body irradiation.

    Science.gov (United States)

    Ruitenberg, Marc J; Wells, Julia; Bartlett, Perry F; Harvey, Alan R; Vukovic, Jana

    2017-06-01

    Birth of new neurons in the hippocampus persists in the brain of adult mammals and critically underpins optimal learning and memory. The process of adult neurogenesis is significantly reduced following brain irradiation and this correlates with impaired cognitive function. In this study, we aimed to compare the long-term effects of two environmental paradigms (i.e. enriched environment and exercise) on adult neurogenesis following high-dose (10Gy) total body irradiation. When housed in standard (sedentary) conditions, irradiated mice revealed a long-lasting (up to 4 months) deficit in neurogenesis in the granule cell layer of the dentate gyrus, the region that harbors the neurogenic niche. This depressive effect of total body irradiation on adult neurogenesis was partially alleviated by exposure to enriched environment but not voluntary exercise, where mice were single-housed with unlimited access to a running wheel. Exposure to voluntary exercise, but not enriched environment, did lead to significant increases in microglia density in the granule cell layer of the hippocampus; our study shows that these changes result from local microglia proliferation rather than recruitment and infiltration of circulating Cx 3 cr1 +/gfp blood monocytes that subsequently differentiate into microglia-like cells. In summary, latent neural precursor cells remain present in the neurogenic niche of the adult hippocampus up to 8 weeks following high-dose total body irradiation. Environmental enrichment can partially restore the adult neurogenic process in this part of the brain following high-dose irradiation, and this was found to be independent of blood monocyte-derived microglia presence. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  3. Improving the prescribing of antibiotics for urinary tract infection.

    Science.gov (United States)

    Peterson, G M; Stanton, L A; Bergin, J K; Chapman, G A

    1997-04-01

    In recent years there have been changes in the recommended antibiotic treatment for urinary tract infections (UTIs). In particular, the use of amoxycillin or co-trimoxazole is now discouraged, with amoxycillin-potassium clavulanate, cephalexin and trimethoprim becoming first-line agents for uncomplicated lower UTIs. To examine whether academic detailing, performed by a pharmacist, could modify prescribing practices for antibiotics used in the treatment of UTI in the community setting. The intervention was conducted in Southern Tasmania, using the remainder of the State as a control area. The target group of general practitioners was sent educational material designed to assist in the appropriate prescribing of antibiotics in the treatment of UTI. A pharmacist then visited each general practitioner and discussed the rational use of antibiotics for UTIs directly with him/her. Outcomes were measured using evaluation feedback from the general practitioners and pharmacoepidemiological data, which were not linked to diagnosis. The key variable examined was the total defined daily doses (DDDs) dispensed for the recommended first-line agents (amoxycillin-potassium clavulanate, cephalexin and trimethoprim) compared with amoxycillin (3 g single-dose form) and co-trimoxazole. The educational programme was very well received by the general practitioners. Changes in the prescribing of antibiotics commonly used for UTIs were evident in both study regions over the course of the study, but the improvements were significantly greater in the intervention area. Educational programmes utilizing academic detailing by pharmacists can modify prescribing practices within the community setting.

  4. Simulation and measurement of total ionizing dose radiation induced image lag increase in pinned photodiode CMOS image sensors

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jing [School of Materials Science and Engineering, Xiangtan University, Hunan (China); State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Chen, Wei, E-mail: chenwei@nint.ac.cn [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Wang, Zujun, E-mail: wangzujun@nint.ac.cn [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Xue, Yuanyuan; Yao, Zhibin; He, Baoping; Ma, Wuying; Jin, Junshan; Sheng, Jiangkun; Dong, Guantao [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China)

    2017-06-01

    This paper presents an investigation of total ionizing dose (TID) induced image lag sources in pinned photodiodes (PPD) CMOS image sensors based on radiation experiments and TCAD simulation. The radiation experiments have been carried out at the Cobalt −60 gamma-ray source. The experimental results show the image lag degradation is more and more serious with increasing TID. Combining with the TCAD simulation results, we can confirm that the junction of PPD and transfer gate (TG) is an important region forming image lag during irradiation. These simulations demonstrate that TID can generate a potential pocket leading to incomplete transfer.

  5. Effect of high-dose preoperative methylprednisolone on pain and recovery after total knee arthroplasty: a randomized, placebo-controlled trial

    DEFF Research Database (Denmark)

    Lunn, Troels; Kristensen, Billy Bjarne; Andersen, Lasse

    2011-01-01

    Total knee arthroplasty (TKA) is associated with severe pain and inflammation despite an extensive multimodal analgesic approach, but the effect of high-dose glucocorticoid administration has not been studied.......Total knee arthroplasty (TKA) is associated with severe pain and inflammation despite an extensive multimodal analgesic approach, but the effect of high-dose glucocorticoid administration has not been studied....

  6. Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA Goddard Space Flight Center and NASA Electronic Parts and Packaging Program

    Science.gov (United States)

    Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Cochran, Donna J.; Label, Kenneth A.; Ladbury, Raymond L.; Mondy, Timothy K.; O'Bryan, Martha V.; hide

    2017-01-01

    Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices. Displacement Damage, Optoelectronics, Proton Damage, Single Event Effects, and Total Ionizing Dose.

  7. Learning from prescribing errors

    OpenAIRE

    Dean, B

    2002-01-01

    

 The importance of learning from medical error has recently received increasing emphasis. This paper focuses on prescribing errors and argues that, while learning from prescribing errors is a laudable goal, there are currently barriers that can prevent this occurring. Learning from errors can take place on an individual level, at a team level, and across an organisation. Barriers to learning from prescribing errors include the non-discovery of many prescribing errors, lack of feedback to th...

  8. Ionizing Radiation Effects on the Noise of 65 nm CMOS Transistors for Pixel Sensor Readout at Extreme Total Dose Levels

    CERN Document Server

    Re, V.; Manghisoni, M.; Riceputi, E.; Traversi, G.; Ratti, L.

    2018-01-01

    This paper is focused on the study of the noise performance of 65 nm CMOS transistors at extremely high total ionizing dose (TID) levels of the order of several hundreds of Mrad(SiO2). Noise measurements are reported and discussed, analyzing radiation effects on 1/ f noise and channel thermal noise. In nMOSFETs, up to 10 Mrad(SiO2), the experimental behavior is consistent with a damage mechanism mainly associ- ated with lateral isolation oxides, and can be modeled by parasitic transistors turning on after irradiation and contributing to the total noise of the device. At very high dose, these parasitic transistors tend to be turned off by negative charge accumulating in interface states and compensating radiation-induced positive charge building up inside thick isolation oxides. Effects associated with ionization and hydrogen transport in spacer oxides may become dominant at 600 Mrad(SiO2) and may explain the observed noise behavior at extremely high TID. The results of this analysis provide an understanding o...

  9. Dose measurements in the treatment of mycosis fungoides with total skin irradiation using a 4 MeV electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Poli, M.E.R. [Hospital Real e Benemerita Sociedade Portuguesa de Beneficencia (Brazil); Todo, A.S.; Campos, L.L. [Instituto de Pesquisas Energeticas e Nucleares, CNEN/SP Travessa R, Sao Paulo (Brazil)

    2000-05-01

    The total skin irradiation (TSI) is one of the most efficient techniques in the treatment administered with curative intent of the mycosis fungoides. The cure may be obtained in 10% to 40% of cases. The original Stanford University technique, created in 1960, was applied in a 4.8 MeV linear accelerator, that provided 2.5 MeV electrons in the patient, by the use of 4 couple beams with the patient placed in front of the beam, 3 meters distant from the apparatus. In this work we describe a 4 MeV electrons beam treatment method. We intend to improve the uniformity of the dose in the patient, as well, to reduce the problems with the overlapping treatment fields, that occurs in conventional treatment that uses 1 meter of focus-skin distance, and the treatment time to the patient. Only one modification was done in the apparatus: the dose rate for this treatment was doubled. The patient is placed on a rotative base and he assumes successively 6 positions: stand up and perpendicular to the beam, distant 2.83 meters from the gantry, with 60 degrees of interval between the rotations. In each position, the patient receives a couple of beams (the beam angulation is 19.5 degrees above the transversal axis in the middle of the patient and 19.5 degrees below it). The dosimetric data obtained were compared to the international protocols (AAPM). The delivered doses in the patient were measured with thermoluminescent dosimeters placed on skin surface and with Kodak XV-2 films placed between different slabs of an anthropomorphic phantom. The dose distribution in the phantom shows a good uniformity, in all thickness of interest, so it is possible to use this technique in the treatment of the mycosis fungoides as well Kaposi's sarcoma. (author)

  10. Noise reduction technology reduces radiation dose in chronic total occlusions percutaneous coronary intervention: a propensity score-matched analysis.

    Science.gov (United States)

    Maccagni, Davide; Benincasa, Susanna; Bellini, Barbara; Candilio, Luciano; Poletti, Enrico; Carlino, Mauro; Colombo, Antonio; Azzalini, Lorenzo

    2018-03-23

    Chronic total occlusions (CTO) percutaneous coronary intervention (PCI) is associated with high radiation dose. Our study aim was to evaluate the impact of the implementation of a noise reduction technology (NRT) on patient radiation dose during CTO PCI. A total of 187 CTO PCIs performed between February 2016 and May 2017 were analyzed according to the angiographic systems utilized: Standard (n = 60) versus NRT (n = 127). Propensity score matching (PSM) was performed to control for differences in baseline characteristics. Primary endpoints were Cumulative Air Kerma at Interventional Reference Point (AK at IRP), which correlates with patient's tissue reactions; and Kerma Area Product (KAP), a surrogate measure of patient's risk of stochastic radiation effects. An Efficiency Index (defined as fluoroscopy time/AK at IRP) was calculated for each procedure. Image quality was evaluated using a 5-grade Likert-like scale. After PSM, n = 55 pairs were identified. Baseline and angiographic characteristics were well matched between groups. Compared to the Standard system, NRT was associated with lower AK at IRP [2.38 (1.80-3.66) vs. 3.24 (2.04-5.09) Gy, p = 0.035], a trend towards reduction for KAP [161 (93-244) vs. 203 (136-363) Gycm 2 , p = 0.069], and a better Efficiency Index [16.75 (12.73-26.27) vs. 13.58 (9.92-17.63) min/Gy, p = 0.003]. Image quality was similar between the two groups (4.39 ± 0.53 Standard vs. 4.34 ± 0.47 NRT, p = 0.571). In conclusion, compared with a Standard system, the use of NRT in CTO PCI is associated with lower patient radiation dose and similar image quality.

  11. Hyperfractionated high-dose total body irradiation in bone marrow transplantation for Ph{sup 1}-positive acute lymphoblastic leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Akira; Ebihara, Yasuhiro; Mitsui, Tetsuo [Tokyo Univ. (Japan). Hospital of the Institute of Medical Science] [and others

    1998-12-01

    In two cases of Philadelphia-positive childhood acute lymphoblastic leukemia (Ph{sup 1} ALL), we performed allogeneic bone marrow transplantation (AlloBMT) with preconditioning regimen, including hyperfractionated high-dose total body irradiation (TBI) (13.5 Gy, in 9 fractions). Their disease statuses at BMT were hematological relapse in case 1 and molecular relapse in case 2. Bone marrow donors were unrelated in case 1, and HLA was a partially mismatched mother in case 2. Regimen-related toxicity was tolerable in both cases. Hematological recovery was rapid, and engraftment was obtained on day 14 in case 1 and on day 12 in case 2. BCR/ABL message in bone marrow disappeared on day 89 in case 1 and on day 19 in case 2 and throughout their subsequent clinical courses. Although short-term MTX and Cy-A continuous infusion were used for GVHD prophylaxis, grade IV GVHD was observed in case 1 and grade III in case 2. Both cases experienced hemorrhagic cystitis because of adenovirus type 11 infection. Although case 1 died of interstitial pneumonitis on day 442, case 2 has been free of disease through day 231. AlloBMT for Ph{sup 1} ALL with preconditioning regimen including hyperfractionated high-dose TBI is considered to be worth further investigation. (author)

  12. Analysis of functional failure mode of commercial deep sub-micron SRAM induced by total dose irradiation

    International Nuclear Information System (INIS)

    Zheng Qi-Wen; Cui Jiang-Wei; Zhou Hang; Yu De-Zhao; Yu Xue-Feng; Lu Wu; Guo Qi; Ren Di-Yuan

    2015-01-01

    Functional failure mode of commercial deep sub-micron static random access memory (SRAM) induced by total dose irradiation is experimentally analyzed and verified by circuit simulation. We extensively characterize the functional failure mode of the device by testing its electrical parameters and function with test patterns covering different functional failure modes. Experimental results reveal that the functional failure mode of the device is a temporary function interruption caused by peripheral circuits being sensitive to the standby current rising. By including radiation-induced threshold shift and off-state leakage current in memory cell transistors, we simulate the influence of radiation on the functionality of the memory cell. Simulation results reveal that the memory cell is tolerant to irradiation due to its high stability, which agrees with our experimental result. (paper)

  13. Out-Patient Prescribing Practices at Mbagathi District Hospital ...

    African Journals Online (AJOL)

    On average, each patient was prescribed 3.85 types of drugs. A total of 835 drugs were prescribed by generic name, accounting for 25.6% of total number of drugs prescribed (1,506). Out of 391 sampled prescriptions, 266 had antibiotics accounting for (68.0%). A relatively small proportion of the prescriptions, 9.5% had an ...

  14. Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA Goddard Space Flight Center and Selected NASA Electronic Parts and Packaging Program

    Science.gov (United States)

    Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Cochran, Donna J.; LaBel, Kenneth A.; Ladbury, Raymond L.; Lauenstein, Jean-Marie; Mondy, Timothy K.; hide

    2017-01-01

    Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.

  15. Opioid-prescribing practices in chronic cancer pain in a tertiary care pain clinic

    Directory of Open Access Journals (Sweden)

    Raghu S Thota

    2011-01-01

    Full Text Available Introduction: Under treatment of pain is a recognized global issue. Opioid analgesic medication is the mainstay of treatment in cancer patients as per the World Health Organization (WHO pain relief ladder, yet 50% of cancer patients worldwide do not receive adequate pain relief or are undertreated. Aim: The aim of this study was to audit the ongoing opioid-prescribing practices in our tertiary cancer pain clinic during January-June 2010. Materials& Methods: The prescribed type of opioid, dose, dosing interval, and laxatives details were analyzed. Results: Five hundred pain files were reviewed and 435 were found complete for audit. Three hundred forty-eight (80% patients were prescribed opioids. Two hundred fifty-nine (74.4% received weak opioids while 118 (33.9% received strong opioids. A total of 195 (45% patients had moderate and 184 (42% had severe pain. Ninety-three (26.7% patients received morphine; however, only 31.5% (58 of 184 in severe pain received morphine as per the WHO pain ladder. Only 73 of 93 (78.4% patients received an adequate dose of morphine with an adequate dosing interval and only 27 (29% were prescribed laxatives with morphine. Conclusion: This study shows that the under treatment of pain and under dosing of opioids coupled with improper side effect management are major issues.

  16. The Relative Effects of Manual Versus Automatic Exposure Control on Radiation Dose to Vital Organs in Total Hip Arthroplasty.

    Science.gov (United States)

    Harper, Katharine D; Li, Shidong; Jennings, Rachel; Amer, Kamil M; Haydel, Christopher; Ali, Sayed

    2018-01-01

    of a total hip arthroplasty implant, exposure values increased threefold at some anatomic locations and surpassed 1 mSv, the generally accepted threshold for concern. Radiation exposure to radiosensitive organs increased up to threefold after total hip implantation with automatic exposure control and up to approximately 1.5 times with the manual protocol. Doses were greater with manual exposures than with automatic exposure control (except at the control probe on the stomach, where exposure was negligible, as expected). However, after implant placement, doses increased more with automatic exposure control than with manual exposure. This difference can be attributed to increased scatter and the difficulty of dose modification because of the density of the implant. Current radiographic protocols should be reassessed to determine if the benefits of frequent radiographs outweigh the newly demonstrated risks.

  17. Medication errors: prescribing faults and prescription errors.

    Science.gov (United States)

    Velo, Giampaolo P; Minuz, Pietro

    2009-06-01

    1. Medication errors are common in general practice and in hospitals. Both errors in the act of writing (prescription errors) and prescribing faults due to erroneous medical decisions can result in harm to patients. 2. Any step in the prescribing process can generate errors. Slips, lapses, or mistakes are sources of errors, as in unintended omissions in the transcription of drugs. Faults in dose selection, omitted transcription, and poor handwriting are common. 3. Inadequate knowledge or competence and incomplete information about clinical characteristics and previous treatment of individual patients can result in prescribing faults, including the use of potentially inappropriate medications. 4. An unsafe working environment, complex or undefined procedures, and inadequate communication among health-care personnel, particularly between doctors and nurses, have been identified as important underlying factors that contribute to prescription errors and prescribing faults. 5. Active interventions aimed at reducing prescription errors and prescribing faults are strongly recommended. These should be focused on the education and training of prescribers and the use of on-line aids. The complexity of the prescribing procedure should be reduced by introducing automated systems or uniform prescribing charts, in order to avoid transcription and omission errors. Feedback control systems and immediate review of prescriptions, which can be performed with the assistance of a hospital pharmacist, are also helpful. Audits should be performed periodically.

  18. Computational opioid prescribing: a novel application of clinical pharmacokinetics.

    Science.gov (United States)

    Linares, Oscar A; Linares, Annemarie L

    2011-01-01

    We implemented a pharmacokinetics-based mathematical modeling technique using algebra to assist prescribers with point-of-care opioid dosing. We call this technique computational opioid prescribing (COP). Because population pharmacokinetic parameter values are needed to estimate drug dosing regimen designs for individual patients using COP, and those values are not readily available to prescribers because they exist scattered in the vast pharmacology literature, we estimated the population pharmacokinetic parameter values for 12 commonly prescribed opioids from various sources using the bootstrap resampling technique. Our results show that opioid dosing regimen design, evaluation, and modification is feasible using COP. We conclude that COP is a new technique for the quantitative assessment of opioid dosing regimen design evaluation and adjustment, which may help prescribers to manage acute and chronic pain at the point-of-care. Potential benefits include opioid dose optimization and minimization of adverse opioid drug events, leading to potential improvement in patient treatment outcomes and safety.

  19. Radiation-induced rib fracture after stereotactic body radiotherapy with a total dose of 54-56 Gy given in 9-7 fractions for patients with peripheral lung tumor: impact of maximum dose and fraction size.

    Science.gov (United States)

    Aoki, Masahiko; Sato, Mariko; Hirose, Katsumi; Akimoto, Hiroyoshi; Kawaguchi, Hideo; Hatayama, Yoshiomi; Ono, Shuichi; Takai, Yoshihiro

    2015-04-22

    Radiation-induced rib fracture after stereotactic body radiotherapy (SBRT) for lung cancer has been recently reported. However, incidence of radiation-induced rib fracture after SBRT using moderate fraction sizes with a long-term follow-up time are not clarified. We examined incidence and risk factors of radiation-induced rib fracture after SBRT using moderate fraction sizes for the patients with peripherally located lung tumor. During 2003-2008, 41 patients with 42 lung tumors were treated with SBRT to 54-56 Gy in 9-7 fractions. The endpoint in the study was radiation-induced rib fracture detected by CT scan after the treatment. All ribs where the irradiated doses were more than 80% of prescribed dose were selected and contoured to build the dose-volume histograms (DVHs). Comparisons of the several factors obtained from the DVHs and the probabilities of rib fracture calculated by Kaplan-Meier method were performed in the study. Median follow-up time was 68 months. Among 75 contoured ribs, 23 rib fractures were observed in 34% of the patients during 16-48 months after SBRT, however, no patients complained of chest wall pain. The 4-year probabilities of rib fracture for maximum dose of ribs (Dmax) more than and less than 54 Gy were 47.7% and 12.9% (p = 0.0184), and for fraction size of 6, 7 and 8 Gy were 19.5%, 31.2% and 55.7% (p = 0.0458), respectively. Other factors, such as D2cc, mean dose of ribs, V10-55, age, sex, and planning target volume were not significantly different. The doses and fractionations used in this study resulted in no clinically significant rib fractures for this population, but that higher Dmax and dose per fraction treatments resulted in an increase in asymptomatic grade 1 rib fractures.

  20. Radiation-induced rib fracture after stereotactic body radiotherapy with a total dose of 54–56 Gy given in 9–7 fractions for patients with peripheral lung tumor: impact of maximum dose and fraction size

    International Nuclear Information System (INIS)

    Aoki, Masahiko; Sato, Mariko; Hirose, Katsumi; Akimoto, Hiroyoshi; Kawaguchi, Hideo; Hatayama, Yoshiomi; Ono, Shuichi; Takai, Yoshihiro

    2015-01-01

    Radiation-induced rib fracture after stereotactic body radiotherapy (SBRT) for lung cancer has been recently reported. However, incidence of radiation-induced rib fracture after SBRT using moderate fraction sizes with a long-term follow-up time are not clarified. We examined incidence and risk factors of radiation-induced rib fracture after SBRT using moderate fraction sizes for the patients with peripherally located lung tumor. During 2003–2008, 41 patients with 42 lung tumors were treated with SBRT to 54–56 Gy in 9–7 fractions. The endpoint in the study was radiation-induced rib fracture detected by CT scan after the treatment. All ribs where the irradiated doses were more than 80% of prescribed dose were selected and contoured to build the dose-volume histograms (DVHs). Comparisons of the several factors obtained from the DVHs and the probabilities of rib fracture calculated by Kaplan-Meier method were performed in the study. Median follow-up time was 68 months. Among 75 contoured ribs, 23 rib fractures were observed in 34% of the patients during 16–48 months after SBRT, however, no patients complained of chest wall pain. The 4-year probabilities of rib fracture for maximum dose of ribs (Dmax) more than and less than 54 Gy were 47.7% and 12.9% (p = 0.0184), and for fraction size of 6, 7 and 8 Gy were 19.5%, 31.2% and 55.7% (p = 0.0458), respectively. Other factors, such as D2cc, mean dose of ribs, V10–55, age, sex, and planning target volume were not significantly different. The doses and fractionations used in this study resulted in no clinically significant rib fractures for this population, but that higher Dmax and dose per fraction treatments resulted in an increase in asymptomatic grade 1 rib fractures

  1. Radiation Dose Risk and Diagnostic Benefit in Imaging Investigations

    OpenAIRE

    Dobrescu, Lidia; Rădulescu, Gheorghe-Cristian

    2015-01-01

    The paper presents many facets of medical imaging investigations radiological risks. The total volume of prescribed medical investigations proves a serious lack in monitoring and tracking of the cumulative radiation doses in many health services. Modern radiological investigations equipment is continuously reducing the total dose of radiation due to improved technologies, so a decrease in per caput dose can be noticed, but the increasing number of investigations has determined a net increase ...

  2. Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

    Science.gov (United States)

    Liu, Yan; Ma, Jianhua; Fan, Yi; Liang, Zhengrong

    2012-12-07

    Previous studies have shown that by minimizing the total variation (TV) of the to-be-estimated image with some data and other constraints, piecewise-smooth x-ray computed tomography (CT) can be reconstructed from sparse-view projection data without introducing notable artifacts. However, due to the piecewise constant assumption for the image, a conventional TV minimization algorithm often suffers from over-smoothness on the edges of the resulting image. To mitigate this drawback, we present an adaptive-weighted TV (AwTV) minimization algorithm in this paper. The presented AwTV model is derived by considering the anisotropic edge property among neighboring image voxels, where the associated weights are expressed as an exponential function and can be adaptively adjusted by the local image-intensity gradient for the purpose of preserving the edge details. Inspired by the previously reported TV-POCS (projection onto convex sets) implementation, a similar AwTV-POCS implementation was developed to minimize the AwTV subject to data and other constraints for the purpose of sparse-view low-dose CT image reconstruction. To evaluate the presented AwTV-POCS algorithm, both qualitative and quantitative studies were performed by computer simulations and phantom experiments. The results show that the presented AwTV-POCS algorithm can yield images with several notable gains, in terms of noise-resolution tradeoff plots and full-width at half-maximum values, as compared to the corresponding conventional TV-POCS algorithm.

  3. Research on total-dose hardening for H-gate PD NMOSFET/SIMOX by ion implanting into buried oxide

    International Nuclear Information System (INIS)

    Qian Cong; Zhang Zhengxuan; Zhang Feng; Lin Chenglu

    2008-01-01

    In this work, we investigate the back-gate I-V characteristics for two kinds of NMOSFET/SIMOX transistors with H gate structure fabricated on two different SOI wafers. A transistors are made on the wafer implanted with Si + and then annealed in N 2 , and B transistors are made on the wafer without implantation and annealing. It is demonstrated experimentally that A transistors have much less back-gate threshold voltage shift ΔV th than B transistors under X-ray total close irradiation. Subthreshold charge separation technique is employed to estimate the build-up of oxide charge and interface traps during irradiation, showing that the reduced ΔV th for A transistors is mainly due to its less build-up of oxide charge than B transistors. Photo-luminescence (PL) research indicates that Si implantation results in the formation of silicon nanocrystalline (nanocluster) whose size increases with the implant dose. This structure can trap electrons to compensate the positive charge build-up in the buried oxide during irradiation, and thus reduce the threshold voltage negative shift. (authors)

  4. E-Prescribing Errors in Community Pharmacies: Exploring Consequences and Contributing Factors

    Science.gov (United States)

    Stone, Jamie A.; Chui, Michelle A.

    2014-01-01

    Objective To explore types of e-prescribing errors in community pharmacies and their potential consequences, as well as the factors that contribute to e-prescribing errors. Methods Data collection involved performing 45 total hours of direct observations in five pharmacies. Follow-up interviews were conducted with 20 study participants. Transcripts from observations and interviews were subjected to content analysis using NVivo 10. Results Pharmacy staff detected 75 e-prescription errors during the 45 hour observation in pharmacies. The most common e-prescribing errors were wrong drug quantity, wrong dosing directions, wrong duration of therapy, and wrong dosage formulation. Participants estimated that 5 in 100 e-prescriptions have errors. Drug classes that were implicated in e-prescribing errors were antiinfectives, inhalers, ophthalmic, and topical agents. The potential consequences of e-prescribing errors included increased likelihood of the patient receiving incorrect drug therapy, poor disease management for patients, additional work for pharmacy personnel, increased cost for pharmacies and patients, and frustrations for patients and pharmacy staff. Factors that contribute to errors included: technology incompatibility between pharmacy and clinic systems, technology design issues such as use of auto-populate features and dropdown menus, and inadvertently entering incorrect information. Conclusion Study findings suggest that a wide range of e-prescribing errors are encountered in community pharmacies. Pharmacists and technicians perceive that causes of e-prescribing errors are multidisciplinary and multifactorial, that is to say e-prescribing errors can originate from technology used in prescriber offices and pharmacies. PMID:24657055

  5. Opioid Prescribing PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second public service announcement is based on the July 2017 CDC Vital Signs report. Higher opioid prescribing puts patients at risk for addiction and overdose. Learn what can be done about this serious problem.

  6. Confined prostate cancer treated by conformational irradiation with intensity modulation with or without echography repositioning: is the dose received equivalent to the prescribed dose?; Cancer prostatique localise traite par irradiation conformationnelle avec modulation d'intensite avec ou sans repositionnement echographique: la dose recue est-elle equivalente a la dose prescrite?

    Energy Technology Data Exchange (ETDEWEB)

    Arnaud, A.; Peignaux, K.; Brenier, J.P.; Truc, G.; Naudy, S.; Maingon, P.; Crehange, G. [Centre Georges-Francois Leclerc, Dept. de Radiotherapie, 21 - Dijon (France); Regis, A. [CHU le Bocage, Service de Radiodiagnostic, 21 - Dijon (France); Deville, C.; Bonnetain, F. [Centre Georges-Francois Leclerc, Dept. de Biostatique, 21 - Dijon (France)

    2006-11-15

    The results suggest it would be possible to dispense a homogenous dose in agreement with the ICRU recommendations, nearer than the forward looking dose when the daily echographic repositioning is applied. This repositioning does not influence significantly the dosimetry for the risk organs. These results will validated in a bigger population. (N.C.)

  7. Contact between doctors and the pharmaceutical industry, their perceptions, and the effects on prescribing habits.

    Directory of Open Access Journals (Sweden)

    Klaus Lieb

    Full Text Available BACKGROUND: The prescribing behaviour of doctors is influenced by the pharmaceutical industry. This study investigated the extent to which contacts with pharmaceutical sales representatives (PSR and the perception of these contacts influence prescribing habits. METHOD: An online questionnaire regarding contact with PSRs and perceptions of this contact was sent to 1,388 doctors, 11.5% (n = 160 of whom completed the survey. Individual prescribing data over a year (number of prescriptions, expenditure, and daily doses for all on-patent branded, off-patent branded, and generic drugs were obtained from the Bavarian Association of Statutory Health Insurance Physicians. RESULTS: 84% of the doctors saw PSR at least once a week, and 14% daily. 69% accepted drug samples, 39% accepted stationery and 37% took part in sponsored continuing medical education (CME frequently. 5 physicians (3% accepted no benefits at all. 43% of doctors believed that they received adequate and accurate information from PSRs frequently or always and 42% believed that their prescribing habits were influenced by PSR visits occasionally or frequently. Practices that saw PSRs frequently had significantly higher total prescriptions and total daily doses (but not expenditure than practices that were less frequently visited. Doctors who believed that they received accurate information from PSRs showed higher expenditures on off-patent branded drugs (thus available as generics and a lower proportion of generics. The eschewal of sponsored CME was associated with a lower proportion of on patent-branded drug prescriptions, lower expenditure on off-patent branded drug prescriptions and a higher proportion of generics. Acceptance of office stationery was associated with higher daily doses. CONCLUSIONS: Avoidance of industry-sponsored CME is associated with more rational prescribing habits. Furthermore, gift acceptance and the belief that one is receiving adequate information from a PSR are

  8. Recovery Profiles of T-Cell Subsets Following Low-Dose Total Body Irradiation and Improvement With Cinnamon

    International Nuclear Information System (INIS)

    Zheng, Xiaodan; Guo, Yuqi; Wang, Lei; Zhang, Honghai; Wang, Shaobo; Wang, Li; An, Lei; Zhou, Xianbin; Li, Xia; Yao, Chengfang

    2015-01-01

    Purpose: Inefficient T-cell reconstitution from x-ray–induced immune damage reduces antitumor response. To understand the profile of T-cell reconstitution after irradiation will overcome the barrier of antitumor immunity. This study aimed to identify the recovery profile of T-cell subsets following x-ray irradiation and to highlight the role of cinnamon on efficient T-cell restoration postexposure in the antitumor response. Methods and Materials: CD3"+, CD8"+, and CD4"+ T cells and Th1, Th2, Th17, and regulatory T (Treg) cells were evaluated at different time points after single low-dose total body irradiation (SLTBI) with or without cinnamon treatments. T-bet, GATA3, RORγt, and Foxp3 signaling specific for Th1, Th2, Th17, and Treg were also analyzed by RT-PCR assay. The effects of cinnamon on efficient T-cell subset reconstitution was confirmed in a lung melanoma model in irradiated mice. Results: Reconstitution of CD4"+ T cells was delayed more than that of CD8"+ T cells in T-cell restoration after SLTBI. The production of IFNγ by Th1 or Tc1 cells was sharply decreased and was accompanied by reduced T-bet mRNA, even when total T-cell numbers had recovered; the frequencies of Th17 and Treg cells and their specific transcription factors (RORγt and Foxp3, respectively) were obviously increased. Irradiation-induced inefficient T-cell reconstitution impaired the antitumor capacities in the lung melanoma model. Pretreatment with cinnamon in irradiated mice accelerated the generation of Th1 and reduced the differentiation of Treg cells by activating T-bet and limiting transcriptions of Foxp3. Improvement resulting from cinnamon pretreatment on the efficient T-cell recovery profile from SLTBI promoted antitumor immunity in the lung melanoma model. Conclusions: T-cell reconstitution from SLTBI was characterized by impaired Th1 and elevated Th17 and Treg cells. Cinnamon effectively improved the imbalance of T-cell subsets by promoting the proliferation of Th1 and

  9. Recovery Profiles of T-Cell Subsets Following Low-Dose Total Body Irradiation and Improvement With Cinnamon

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Xiaodan [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); School of Medicine and Life Science, University of Jinan-Shandong Academy of Medical Science, Jinan (China); Guo, Yuqi [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); Wang, Lei [Second Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan (China); Zhang, Honghai [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); Wang, Shaobo [Shandong University, Jinan (China); Wang, Li [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); An, Lei [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); School of Medicine and Life Science, University of Jinan-Shandong Academy of Medical Science, Jinan (China); Zhou, Xianbin; Li, Xia [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); Yao, Chengfang, E-mail: yaocf9941@163.com [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China)

    2015-12-01

    Purpose: Inefficient T-cell reconstitution from x-ray–induced immune damage reduces antitumor response. To understand the profile of T-cell reconstitution after irradiation will overcome the barrier of antitumor immunity. This study aimed to identify the recovery profile of T-cell subsets following x-ray irradiation and to highlight the role of cinnamon on efficient T-cell restoration postexposure in the antitumor response. Methods and Materials: CD3{sup +}, CD8{sup +}, and CD4{sup +} T cells and Th1, Th2, Th17, and regulatory T (Treg) cells were evaluated at different time points after single low-dose total body irradiation (SLTBI) with or without cinnamon treatments. T-bet, GATA3, RORγt, and Foxp3 signaling specific for Th1, Th2, Th17, and Treg were also analyzed by RT-PCR assay. The effects of cinnamon on efficient T-cell subset reconstitution was confirmed in a lung melanoma model in irradiated mice. Results: Reconstitution of CD4{sup +} T cells was delayed more than that of CD8{sup +} T cells in T-cell restoration after SLTBI. The production of IFNγ by Th1 or Tc1 cells was sharply decreased and was accompanied by reduced T-bet mRNA, even when total T-cell numbers had recovered; the frequencies of Th17 and Treg cells and their specific transcription factors (RORγt and Foxp3, respectively) were obviously increased. Irradiation-induced inefficient T-cell reconstitution impaired the antitumor capacities in the lung melanoma model. Pretreatment with cinnamon in irradiated mice accelerated the generation of Th1 and reduced the differentiation of Treg cells by activating T-bet and limiting transcriptions of Foxp3. Improvement resulting from cinnamon pretreatment on the efficient T-cell recovery profile from SLTBI promoted antitumor immunity in the lung melanoma model. Conclusions: T-cell reconstitution from SLTBI was characterized by impaired Th1 and elevated Th17 and Treg cells. Cinnamon effectively improved the imbalance of T-cell subsets by promoting the

  10. Total external dose equivalent and effective dose derived to the Piedmont population in the period 30 Apr 1986 - 22 Sep 1987

    International Nuclear Information System (INIS)

    Cortissone, C.; Giacomelli, R.; Spezzano, P.; Porzio, L.

    1988-01-01

    Some dosimetric evaluations concerning the population of the Piemonte Region, obtained after the measurements made following the Chernobyl accident, are reported. The individual effective mean dose equivalent derived from the exposure and intake in the period April 30, 1986 - September 22, 1987, is about 0.50 mSv

  11. Electronic prescribing reduces prescribing error in public hospitals.

    Science.gov (United States)

    Shawahna, Ramzi; Rahman, Nisar-Ur; Ahmad, Mahmood; Debray, Marcel; Yliperttula, Marjo; Declèves, Xavier

    2011-11-01

    To examine the incidence of prescribing errors in a main public hospital in Pakistan and to assess the impact of introducing electronic prescribing system on the reduction of their incidence. Medication errors are persistent in today's healthcare system. The impact of electronic prescribing on reducing errors has not been tested in developing world. Prospective review of medication and discharge medication charts before and after the introduction of an electronic inpatient record and prescribing system. Inpatient records (n = 3300) and 1100 discharge medication sheets were reviewed for prescribing errors before and after the installation of electronic prescribing system in 11 wards. Medications (13,328 and 14,064) were prescribed for inpatients, among which 3008 and 1147 prescribing errors were identified, giving an overall error rate of 22·6% and 8·2% throughout paper-based and electronic prescribing, respectively. Medications (2480 and 2790) were prescribed for discharge patients, among which 418 and 123 errors were detected, giving an overall error rate of 16·9% and 4·4% during paper-based and electronic prescribing, respectively. Electronic prescribing has a significant effect on the reduction of prescribing errors. Prescribing errors are commonplace in Pakistan public hospitals. The study evaluated the impact of introducing electronic inpatient records and electronic prescribing in the reduction of prescribing errors in a public hospital in Pakistan. © 2011 Blackwell Publishing Ltd.

  12. Prescribing Patterns of Intravenous Golimumab for Rheumatoid Arthritis.

    Science.gov (United States)

    Brady, Brenna L; Tkacz, Joseph P; Lofland, Jennifer; Meyer, Roxanne; Bolge, Susan C

    2015-09-01

    The use of intravenous golimumab (GLM-IV), in combination with methotrexate, was approved by the US Food and Drug Administration in July 2013 for the treatment of moderate to severe, active rheumatoid arthritis (RA). GLM-IV is available in 50-mg vials, and the prescribing information specifies a dosing regimen of 2 mg/kg at 0 and 4 weeks and then every 8 weeks thereafter. The purpose of this study was to examine the patterns of prescribing and administration of GLM-IV, including the demographic, clinical, and utilization characteristics of patients with RA newly treated with GLM-IV. Rheumatology practices across the continental United States were solicited for a chart-review study. Inclusion criteria were: (1) diagnosis of RA; (2) current treatment with GLM-IV; (3) age ≥18 years; and (4) lack of pregnancy (in female patients). Physicians were offered a monetary incentive for each eligible chart provided. An electronic case-report form was developed to aid in the chart data extraction and included fields for demographic characteristics, available comorbid diagnoses, prior RA treatments, and doses and dates of GLM-IV administration. A total of 117 eligible patient charts from 15 rheumatologist practices were reviewed. The patient sample was predominantly female (81.2%), with a mean (SD) age of 55.4 (14.5) years. A total of 55.6% of patients had evidence of biologic treatment before receiving GLM-IV, and 53% had at least 1 comorbid condition. In total, 300 individual GLM-IV infusions from this sample were reviewed. Due to the relatively recent approval of GLM-IV use by the US Food and Drug Administration, the majority of patients in this sample (69.2%) had received only between 2 and 4 infusions at the time of the review. For infusion records with valid dose data, the mean number of administered vials was 3.6 (0.8) (total dose, 180 mg); the majority of patients received a dose consistent with the prescribed dose of 2 mg/kg. Combination therapy with methotrexate was

  13. Impact of Prior Therapeutic Opioid Use by Emergency Department Providers on Opioid Prescribing Decisions

    Directory of Open Access Journals (Sweden)

    Adam C Pomerleau

    2016-11-01

    Full Text Available INTRODUCTION: Our study sought to examine the opioid analgesic (OA prescribing decisions of emergency department (ED providers who have themselves used OA therapeutically and those who have not. A second objective was to determine if OA prescribing decisions would differ based on the patient's relationship to the provider. METHODS: We distributed an electronic survey to a random sample of ED providers at participating centers in a nationwide research consortium. Question topics included provider attitudes about OA prescribing, prior personal therapeutic use of OAs (indications, dosing, and disposal of leftover medication, and hypothetical analgesic-prescribing decisions for their patients, family members, and themselves for different painful conditions. RESULTS: The total survey population was 957 individuals; 515 responded to the survey, a 54% response rate. Prior personal therapeutic OA use was reported in 63% (95% CI = [58-68]. A majority of these providers (82%; 95% CI = [77-87] took fewer than half the number of pills prescribed. Regarding provider attitudes towards OA prescribing, 66% (95% CI = [61-71] agreed that OA could lead to addiction even with short-term use. When providers were asked if they would prescribe OA to a patient with 10/10 pain from an ankle sprain, 21% (95% CI = [17-25] would for an adult patient, 13% (95% CI = [10-16] would for an adult family member, and 6% (95% CI = [4-8] indicated they themselves would take an opioid for the same pain. When the scenario involved an ankle fracture, 86% (95% CI = [83-89] would prescribe OA for an adult patient, 75% (95% CI = [71-79] for an adult family member, and 52% (95% CI = [47-57] would themselves take OA. Providers who have personally used OA to treat their pain were found to make similar prescribing decisions compared to those who had not. CONCLUSION: No consistent differences in prescribing decisions were found between ED providers based on their prior therapeutic use of OA

  14. Improving antimicrobial prescribing in Irish primary care through electronic data collection and surveillance: a feasibility study.

    Science.gov (United States)

    Galvin, Sandra; Callan, Aoife; Cormican, Martin; Duane, Sinead; Bennett, Kathleen; Murphy, Andrew W; Vellinga, Akke

    2015-07-02

    The increase in the spread of antimicrobial resistance (AMR) in bacterial pathogens and limited availability of new antimicrobials places immense pressure on general practitioners (GPs) to prescribe appropriately. Currently, electronic antimicrobial prescribing data is not routinely collected from GPs in Ireland for surveillance purposes to assess regional specific fluctuations or trends in antimicrobial prescribing. The current study aimed to address this issue by assessing the feasibility of remotely extracting antimicrobial prescribing data from primary care practices in Ireland, for the purpose of assessing prescribing quality using the European Surveillance of Antimicrobial Consumption (ESAC) drug specific quality indicators. Participating practices (n = 30) uploaded data to the Irish Primary Care Research Network (IPCRN). The IPCRN data extraction facility is integrated within the practice patient management software system and permitted the extraction of anonymised patient prescriptions for a one year period, from October 2012 to October 2013. The quality of antimicrobial prescribing was evaluated using the twelve ESAC drug specific quality indicators using the defined daily dose (DDD) per 1,000 inhabitants per day (DID) methodology. National and European prescribing surveillance data (based on total pharmacy sales) was obtained for a comparative analysis. Antimicrobial prescriptions (n = 57,079) for 27,043 patients were obtained from the thirty study practices for a one year period. On average, study practices prescribed a greater proportion of quinolones (37 % increase), in summer compared with winter months, a variation which was not observed in national and European data. In comparison with national data, study practices prescribed higher proportions of β-lactamase-sensitive penicillins (4.98 % vs. 4.3 %) and a greater use of broad spectrum compared to narrow-spectrum antimicrobials (ratio = 9.98 vs. 6.26) was observed. Study practices exceeded the

  15. Increased mortality by septicemia, interstitial pneumonitis and pulmonary fibrosis among bone marrow transplant recipients receiving an increased mean dose rate of total irradiation

    International Nuclear Information System (INIS)

    Ringden, O.; Baaryd, I.; Johansson, B.

    1983-01-01

    Seven bone marrow transplant recipients with acute lymphoblastic leukemia receiving a mean dose rate of 0.07 Gy/min of total body irradiation towards the pelvic midpoint and the lungs had an increased (p<0.01) overall death rate of 86 per cent compared with 33 per cent among 27 patients with acute non-lymphoblastic leukemia or acute lymphoblastic leukemia treated with a mean dose rate of 0.04 Gy/min. Among the patients receiving the higher dose rate there was an increased mortality in causes related to radiation toxicity like early septicemia, interstitial pneumonitis and pulmonary fibrosis, compared with all patients receiving the lower dose rate (p<0.01) and also with 10 patients from this group with acute lymphoblastic leukemia (p<0.02). (Auth.)

  16. Urinary excretion of total isothiocyanates from cruciferous vegetables shows high dose-response relationship and may be a useful biomarker for isothiocyanate exposure

    DEFF Research Database (Denmark)

    Kristensen, Mette; Krogholm, Kirstine Suszkiewicz; Frederiksen, Hanne

    2007-01-01

    in urine was quanti- fied as the cyclocondensation product of 1,2-bezenedithiol by high performance liquid chromatography. Results The total urinary excretion of ITCs correlated significantly with the two doses of ITC from diets with high or low cruciferous content (r(s) = 0.90, P

  17. An evaluation of total disintegration time for three different doses of sublingual fentanyl tablets in patients with breakthrough pain.

    Science.gov (United States)

    Nalamachu, Srinivas

    2013-12-01

    Breakthrough pain is common among patients with cancer and presents challenges to effective pain management. Breakthrough pain is characterized by rapid onset, severe intensity, and duration typically lasting disintegration time of three different doses of sublingual fentanyl tablets in opioid-tolerant patients. This was a single-center, non-randomized, open-label study. Opioid-tolerant adult patients (N = 30) with chronic pain were assigned to one of three dose groups and self-administered a single 100, 200, or 300 μg sublingual fentanyl tablet (Abstral(®), Galena Biopharma, Portland, OR, USA). Time to complete disintegration was measured by each patient with a stopwatch and independently verified by study personnel. Disintegration time (mean ± SD) for sublingual fentanyl tablets (all doses) was 88.2 ± 55.1 s. Mean disintegration times tended to be slightly longer for the 200 μg (96.7 ± 57.9 s) and 300 μg doses (98.6 ± 64.8 s) compared to the 100 μg dose (69.5 ± 40.5 s). Differences were not statistically significant. Disintegration time was not significantly different between men and women and was not affected by age. Sublingual fentanyl tablets dissolved rapidly (average time <2 min) in all patients, with the higher doses taking slightly more time to dissolve.

  18. Dose-response relationship of physical activity to premature and total all-cause and cardiovascular disease mortality in walkers.

    Directory of Open Access Journals (Sweden)

    Paul T Williams

    Full Text Available PURPOSE: To assess the dose-response relationships between cause-specific mortality and exercise energy expenditure in a prospective epidemiological cohort of walkers. METHODS: The sample consisted of the 8,436 male and 33,586 female participants of the National Walkers' Health Study. Walking energy expenditure was calculated in metabolic equivalents (METs, 1 MET = 3.5 ml O2/kg/min, which were used to divide the cohort into four exercise categories: category 1 (≤ 1.07 MET-hours/d, category 2 (1.07 to 1.8 MET-hours/d, category 3 (1.8 to 3.6 MET-hours/d, and category 4 (≥ 3.6 MET-hours/d. Competing risk regression analyses were use to calculate the risk of mortality for categories 2, 3 and 4 relative to category 1. RESULTS: 22.9% of the subjects were in category 1, 16.1% in category 2, 33.3% in category 3, and 27.7% in category 4. There were 2,448 deaths during the 9.6 average years of follow-up. Total mortality was 11.2% lower in category 2 (P = 0.04, 32.4% lower in category 3 (P<10(-12 and 32.9% lower in category 4 (P = 10(-11 than in category 1. For underlying causes of death, the respective risk reductions for categories 2, 3 and 4 were 23.6% (P = 0.008, 35.2% (P<10(-5, and 34.9% (P = 0.0001 for cardiovascular disease mortality; 27.8% (P = 0.18, 20.6% (P = 0.07, and 31.4% (P = 0.009 for ischemic heart disease mortality; and 39.4% (P = 0.18, 63.8% (P = 0.005, and 90.6% (P = 0.002 for diabetes mortality when compared to category 1. For all related mortality (i.e., underlying and contributing causes of death combined, the respective risk reductions for categories 2, 3 and 4 were 18.7% (P = 0.22, 42.5% (P = 0.001, and 57.5% (P = 0.0001 for heart failure; 9.4% (P = 0.56, 44.3% (P = 0.0004, and 33.5% (P = 0.02 for hypertensive diseases; 11.5% (P = 0.38, 41.0% (P<10(-4, and 35.5% (P = 0.001 for dysrhythmias: and 23.2% (P = 0.13, 45.8% (P = 0.0002, and 41.1% (P

  19. Opioid Prescribing PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2017-07-06

    This 60 second public service announcement is based on the July 2017 CDC Vital Signs report. Higher opioid prescribing puts patients at risk for addiction and overdose. Learn what can be done about this serious problem.  Created: 7/6/2017 by Centers for Disease Control and Prevention (CDC).   Date Released: 7/6/2017.

  20. Matrix with Prescribed Eigenvectors

    Science.gov (United States)

    Ahmad, Faiz

    2011-01-01

    It is a routine matter for undergraduates to find eigenvalues and eigenvectors of a given matrix. But the converse problem of finding a matrix with prescribed eigenvalues and eigenvectors is rarely discussed in elementary texts on linear algebra. This problem is related to the "spectral" decomposition of a matrix and has important technical…

  1. Some changes of cholesterol, glucose and total proteins in serum of chicken after effect of low dose of ionizing irradiation

    International Nuclear Information System (INIS)

    Danova, D.; Novakova, J.; Benova, K.; Falis, M.; Sezstakova, E.; Toropila, M.

    2006-01-01

    The aim of investigate was the effect of low-dose ionizing irradiation on the organism of chicken. We investigated changes of concentration of cholesterol and triacylglycerols in time gap 1, 3, 14 and 25 days after expose with a single whole-body gamma irradiation of 3 Gy. (authors)

  2. Physicochemical characterization, antioxidant activity and total phenolic content in 'Gala' apples subjected to different UV-C radiation doses

    Directory of Open Access Journals (Sweden)

    Thaís Gabrielle Dias

    2017-01-01

    Full Text Available UV-C radiation is a food preservation method aimed to extend the life of the product, inactivate microorganisms, and stimulate the synthesis of phenolic compounds. This study aimed to physicochemically characterize and evaluate the antioxidant activity and phenolic content of ‘Gala’ apples subjected to different UV-C radiation doses.The fruits were harvested, sanitized, selected and inserted into a UV-C radiation chamber, and different radiation doses were applied as follows:0 KJ m-2 (0 min., 0.68 KJ m-2 (2 minutes,2.73 KJ m-2 (4 minutes, and 4.10 KJ m-2 (6 minutes. The apples were stored for 120 days at 5 ± 1°C and analyzed after 0, 30, 60, 90, and 120 days of storage. Radiation doses had no influence on parameters, such as weight loss, firmness and Hue angle, and physicochemical aspects, such as pH, soluble solids, titratable acidity and the soluble solids/titratable acidity ratio. The 4.10 KJ m-2 dose was effective and increased the phenolic content and antioxidant activity for up to 90 days while maintaining the content of vitamin C during storage.

  3. Effect of treatment with single total-dose intravenous iron versus daily oral iron(III-hydroxide polymaltose on moderate puerperal iron-deficiency anemia

    Directory of Open Access Journals (Sweden)

    Iyoke CA

    2017-05-01

    Full Text Available Chukwuemeka Anthony Iyoke,1 Fausta Chioma Emegoakor,1 Euzebus Chinonye Ezugwu,1 Lucky Osaheni Lawani,2 Leonard Ogbonna Ajah,1 Jude Anazoeze Madu,3 Hyginus Uzo Ezegwui,1 Frank Okechukwu Ezugwu4 1Department of Obstetrics and Gynaecology, University of Nigeria, Enugu Campus, 2Department of Obstetrics and Gynaecology, Federal Teaching Hospital, Abakaliki, 3Department of Haematology, University of Nigeria, Nsukka, 4Department of Obstetrics and Gynaecology, College of Medicine, Enugu State University, Enugu, Nigeria Background: Iron-deficiency anemia is the most common nutritional cause of anemia in pregnancy and is often responsible for puerperal anemia. Puerperal anemia can impair postpartum maternal and neonatal well-being. Objective: To determine the effect of treatment of moderate puerperal iron-deficiency anemia using a single intravenous total-dose iron dextran versus daily single dose oral iron(III-hydroxide polymaltose. Methodology: A randomized controlled study in which postpartum women with moderate iron-deficiency anemia were randomized into treatment with either a single total-dose intravenous iron dextran or with daily single doses of oral iron(III-hydroxide polymaltose tablets for 6 weeks. Effects on hemoglobin concentration using either method were compared at 6 weeks postpartum. Analysis was per protocol using SPSS version 17 for windows. P-values ≤0.05 were considered significant. Results: Two hundred eighty-four women were recruited for the study: 142 women received single total dose intravenous infusion of iron dextran while 142 received daily oral iron(III-hydroxide polymaltose tablets. Approximately 84.0% (237/282 completed the study and were analyzed including 81% (115/142 of those randomized to injectable iron therapy compared to 85.9% (122/142 of those randomized to oral treatment. The proportions of women who had attained hemoglobin concentration of at least 10 g/dL by the 6 weeks postpartum visit did not differ

  4. Effect of different doses of aerobic exercise on total white blood cell (WBC and WBC subfraction number in postmenopausal women: results from DREW.

    Directory of Open Access Journals (Sweden)

    Neil M Johannsen

    Full Text Available BACKGROUND: Elevated total white blood cell (WBC count is associated with an increased risk of coronary heart disease and death. Aerobic exercise is associated with lower total WBC, neutrophil, and monocyte counts. However, no studies have evaluated the effect of the amount of aerobic exercise (dose on total WBC and WBC subfraction counts. PURPOSE: To examine the effects of 3 different doses of aerobic exercise on changes in total WBC and WBC subfraction counts and independent effects of changes in fitness, adiposity, markers of inflammation (IL-6, TNF-α, C-reactive protein, fasting glucose metabolism, and adiponectin. METHODS: Data from 390 sedentary, overweight/obese postmenopausal women from the DREW study were used in these analyses. Women were randomized to a non-exercise control group or one of 3 exercise groups: energy expenditure of 4, 8, or 12 kcal kg(-1⋅week(-1 (KKW for 6 months at an intensity of 50% VO2peak. RESULTS: A dose-dependent decrease in total WBC counts (trend P = 0.002 was observed with a significant decrease in the 12KKW group (-163.1±140.0 cells/µL; mean±95%CI compared with the control (138.6±144.7 cells/µL. A similar response was seen in the neutrophil subfraction (trend P = 0.001 with a significant decrease in the 12KKW group (-152.6±115.1 cells/µL compared with both the control and 4KKW groups (96.4±119.0 and 21.9±95.3 cells/µL, respectively and in the 8KKW group (-102.4±125.0 cells/µL compared with the control. When divided into high/low baseline WBC categories (median split, a dose-dependent decrease in both total WBCs (P = 0.003 and neutrophils (P<0.001 was observed in women with high baseline WBC counts. The effects of exercise dose on total WBC and neutrophil counts persisted after accounting for significant independent effects of change in waist circumference and IL-6. CONCLUSION: Aerobic exercise training reduces total WBC and neutrophil counts, in a dose-dependent manner, in

  5. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    International Nuclear Information System (INIS)

    Kaur, H; Kumar, S; Sarkar, B; Ganesh, T; Giri, U; Jassal, K; Rathinamuthu, S; Gulia, G; Gopal, V; Mohanti, B; Munshi, A

    2016-01-01

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm"2 size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

  6. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, H; Kumar, S; Sarkar, B; Ganesh, T; Giri, U; Jassal, K; Rathinamuthu, S; Gulia, G; Gopal, V; Mohanti, B; Munshi, A [Fortis Memorial Research Institute, Gurgaon, Haryana (India)

    2016-06-15

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

  7. Possible changes in the dose of biologically active ultraviolet radiation received by the biosphere in the summertime Arctic due to total ozone interannual variability

    Energy Technology Data Exchange (ETDEWEB)

    Gruzdev, Aleksandr N. (Institute of Atmospheric Physics, Russian Academy of Sciences, Moscow (Russian Federation))

    1994-12-01

    Data for total ozone measurements since 1972 from the world ozone measuring network have been analyzed to study ozone interannual variability and estimate its possible effect on the UV-B dose received by the arctic biosphere. Possible interannual changes in the UV-B dose received by DNA associated with overall interannual ozone variability, as well as with the quasi-biennial oscillation (QBO) in total ozone were computed for different summer months. In general, the largest interannual variations in UV-B dose may occur in the Russian Arctic, whereas the possible variations in the Canadian Arctic are the smallest. Overall variations in the UV-B dose received by DNA can exceed 25% (2[sigma] criterion) in the Taimyr and Severnaya Zemlya for June and July, and 30% in the Laptev Sea for August. In the European sector of the Arctic, the possible variations are greater than 10%, and can exceed 15% in the north Norwegian Sea for July and 20% in Spitsbergen for August. Possible overall variations in the Canadian Arctic and Alaska are [<=]10%, reaching 15% in Alaska for August, however. The total ozone QBO can also cause essential and (statistically) predicted changes in UV-B radiation. In general, the UV-B dose received by DNA is found to be greater in the Arctic during the westerly phase of the QBO of the equatorial stratospheric wind at 50 mb level than during the easterly phase. The difference can reach or exceed 15% (relative to the mean value) in Taimyr for June and in Severnaya Zemlya for July and August. In northern Europe and Iceland, the difference can reach 10% for August. In the Canadian Arctic, the QBO-related effect is small. In Alaska, the appropriate difference in UV-B dose has an opposite sign for August, exceeding 5% in magnitude

  8. TLD-300 detectors for separate measurement of total and gamma absorbed dose distributions of single, multiple, and moving-field neutron treatments

    International Nuclear Information System (INIS)

    Rassow, J.

    1984-01-01

    Fast neutron therapy requirements, because of the poor depth dose characteristic of present therapeutical sources, are at least as complex in treatment plans as photon therapy. The physical part of the treatment planning is very important; however, it is much more complicated than for photons or electrons owing to the need for: Separation of total and gamma absorbed dose distributions (Dsub(T) and Dsub(G)); and more stringent tissue-equivalence conditions of phantoms than in photon therapy. Therefore, methods of clinical dosimetry for the separate determination of total and gamma absorbed dose distributions in irregularly shaped (inhomogeneous) phantoms are needed. A method using TLD-300 (CaF 2 :Tm) detectors is described, which is able to give an approximate solution of the above-mentioned dosimetric requirements. The two independent doses, Dsub(T) and Dsub(G), can be calculated by an on-line computer analysis of the digitalized glow curve of TLD-300 detectors, irradiated with d(14)+Be neutrons of the cyclotron isocentric neutron therapy facility CIRCE in Essen. Results are presented for depth and lateral absorbed dose distributions (Dsub(T) and Dsub(G)) for fixed neutron beams of different field sizes compared with measurements by standard procedures (TE-TE ionization chamber, GM counter) in an A-150 phantom. The TLD-300 results for multiple and moving-field treatments (with and without wedge filters) in a patient simulating irregularly shaped (inhomogeneous) phantoms, are shown together with computer calculations of these dose distributions. The probable causes for some systematic deviations are discussed, which lead to open problems for further investigations owing to features of the detector material and the evaluation method, but mainly to differences in the composition of phantom materials used for the calculations (standard dose distributions) and TLD-300 measurements. (author)

  9. Results of Hematopoietic Stem Cell Transplantation After Treatment With Different High-Dose Total-Body Irradiation Regimens in Five Dutch Centers

    International Nuclear Information System (INIS)

    Loes van Kempen-Harteveld, M.; Brand, Ronald; Kal, Henk B.; Verdonck, Leo F.; Hofman, Pieter; Schattenberg, Anton V.; Maazen, Richard W. van der; Cornelissen, Jan J.; Eijkenboom, Wil M.H.; Lelie, Johannes P. van der; Oldenburger, Foppe; Barge, Renee M.; Biezen, Anja van; Vossen, Jaak M.J.J.; Noordijk, Evert M.; Struikmans, Henk

    2008-01-01

    Purpose: To evaluate results of high-dose total-body irradiation (TBI) regimens for hematopoietic stem cell transplantation. Methods and Materials: A total of 1,032 patients underwent TBI in one or two fractions before autologous or allogeneic hematologic stem cell transplantation for acute leukemia and non-Hodgkin's lymphoma. The TBI regimens were normalized by using the biological effective dose (BED) concept. The BED values were divided into three dose groups. Study end points were relapse incidence (RI), non-relapse mortality (NRM), relapse-free survival (RFS), and overall survival (OS). Multivariate analysis was performed, stratified by disease. Results: In the highest TBI dose group, RI was significantly lower and NRM was higher vs. the lower dose groups. However, a significant influence on RFS and OS was not found. Relapses in the eye region were found only after shielding to very low doses. Age was of significant influence on OS, RFS, and NRM in favor of younger patients. The NRM of patients older than 40 years significantly increased, and OS decreased. There was no influence of age on RI. Men had better OS and RFS and lower NRM. Type of transplantation significantly influenced RI and NRM for patients with acute leukemia and non-Hodgkin's lymphoma. There was no influence on RFS and OS. Conclusions: Both RI and NRM were significantly influenced by the size of the BED of single-dose or two-fraction TBI regimens; OS and RFS were not. Age was of highly significant influence on NRM, but there was no influence of age on RI. Hyperfractionated TBI with a high BED might be useful, assuming NRM can be reduced

  10. Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty; Dosisreduktion in der digitalen Radiografie des Kniegelenkes nach endoprothetischem Gelenkersatz

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, J.K.; Kauczor, H.U.; Weber, M.A. [University Hospital Heidelberg (Germany). Clinic for Diagnostic and Interventional Radiology; Tanner, M.; Ewerbeck, V. [University Hospital Heidelberg (Germany). Center of Orthopedics, Trauma and Spinal Cord Injury; Stiller, W. [German Cancer Research Center (DKFZ), Radiology (E010), Heidelberg (Germany); Burkholder, I. [Univ. of Applied Sciences of the Saarland, Dept. of Nursing and Health, Saarbruecken (Germany)

    2015-08-15

    To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. In this prospective randomized study 278 radiographs of the knee in follow-up of total-knee arthroplasty were performed with standard and 37 % reduced radiation dose. The evaluation of the plain-radiographs was conducted using the following criteria: bone-implant interface, implant-surface character, implant-implant discrimination and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score ≥ 3 or more than 2 criteria with ≥ 2 points, the radiograph was score das ''not assessable''. The study was designed as non-inferiority-trial. 100 % of examined radiographs were scored as assessable, hence no statistical inferiority between the examinations with standard and reduced dose could be observed. Singular assessment of the defined criteria was likewise dose-independent. Plain-radiography of the knee following total-knee arthroplasty can be performed with 63 % of standard dose without loss of diagnostic validity.

  11. Time- and radiation-dose dependent changes in the plasma proteome after total body irradiation of non-human primates: Implications for biomarker selection.

    Directory of Open Access Journals (Sweden)

    Stephanie D Byrum

    Full Text Available Acute radiation syndrome (ARS is a complex multi-organ disease resulting from total body exposure to high doses of radiation. Individuals can be exposed to total body irradiation (TBI in a number of ways, including terrorist radiological weapons or nuclear accidents. In order to determine whether an individual has been exposed to high doses of radiation and needs countermeasure treatment, robust biomarkers are needed to estimate radiation exposure from biospecimens such as blood or urine. In order to identity such candidate biomarkers of radiation exposure, high-resolution proteomics was used to analyze plasma from non-human primates following whole body irradiation (Co-60 at 6.7 Gy and 7.4 Gy with a twelve day observation period. A total of 663 proteins were evaluated from the plasma proteome analysis. A panel of plasma proteins with characteristic time- and dose-dependent changes was identified. In addition to the plasma proteomics study reported here, we recently identified candidate biomarkers using urine from these same non-human primates. From the proteomic analysis of both plasma and urine, we identified ten overlapping proteins that significantly differentiate both time and dose variables. These shared plasma and urine proteins represent optimal candidate biomarkers of radiation exposure.

  12. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma: an open clinical study and pooled data analysis.

    Science.gov (United States)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars; Skov, Lone; Petersen, Peter Meidahl; Loft, Annika; Specht, Lena

    2015-05-01

    Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Quantifying the importance of pMHC valency, total pMHC dose and frequency on nanoparticle therapeutic efficacy.

    Science.gov (United States)

    Sugarman, Jordan; Tsai, Sue; Santamaria, Pere; Khadra, Anmar

    2013-05-01

    Nanoparticles (NPs) coated with β-cell-specific peptide major histocompatibility complex (pMHC) class I molecules can effectively restore normoglycemia in spontaneously diabetic nonobese diabetic mice. They do so by expanding pools of cognate memory autoreactive regulatory CD8+ T cells that arise from naive low-avidity T-cell precursors to therapeutic levels. Here we develop our previously constructed mathematical model to explore the effects of compound design parameters (NP dose and pMHC valency) on therapeutic efficacy with the underlying hypothesis that the functional correlates of the therapeutic response (expansion of autoregulatory T cells and deletion of autoantigen-loaded antigen-presenting cells by these T cells) are biphasic. We show, using bifurcation analysis, that the model exhibits a 'resonance'-like behavior for a given range of NP dose in which bistability between the healthy state (possessing zero level of effector T-cell population) and autoimmune state (possessing elevated level of the same population) disappears. A heterogeneous population of model mice subjected to several treatment protocols under these new conditions is conducted to quantify both the average percentage of autoregulatory T cells in responsive and nonresponsive model mice, and the average valency-dependent minimal optimal dose needed for effective therapy. Our results reveal that a moderate increase (≥1.6-fold) in the NP-dependent expansion rate of autoregulatory T-cell population leads to a significant increase in the efficacy and the area corresponding to the effective treatment regimen, provided that NP dose ≥8 μg. We expect the model developed here to generalize to other autoimmune diseases and serve as a computational tool to understand and optimize pMHC-NP-based therapies.

  14. Evaluation of Total Daily Dose and Glycemic Control for Patients Taking U-500 Insulin Admitted to the Hospital

    Science.gov (United States)

    2016-04-27

    mail:jack.e.lewi.mil@mail.mil Key Words: U-500 regular insulin , inpatient diabetes mellitus, insulin resistance Conflict of Interest Statements...500 regular insulin are severely insulin resistant requiring high doses of insulin . It has been observed that a patient’s insulin requirements may...concentrated than U-100 regular insulin and is generally used in patients with severe insulin resistance requiring greater than 200 units of insulin

  15. TU-F-CAMPUS-T-01: Dose and Energy Spectra From Neutron Induced Radioactivity in Medical Linear Accelerators Following High Energy Total Body Irradiation

    International Nuclear Information System (INIS)

    Keehan, S; Taylor, M; Franich, R; Smith, R; Dunn, L; Kron, T

    2015-01-01

    Purpose: To assess the risk posed by neutron induced activation of components in medical linear accelerators (linacs) following the delivery of high monitor unit 18 MV photon beams such as used in TBI. Methods: Gamma spectroscopy was used to identify radioisotopes produced in components of a Varian 21EX and an Elekta Synergy following delivery of photon beams. Dose and risk estimates for TBI were assessed using dose deliveries from an actual patient treatment. A 1 litre spherical ion chamber (PTW, Germany) has been used to measure the dose at the beam exit window and at the total body irradiation (TBI) treatment couch following large and small field beams with long beam-on times. Measurements were also made outside of the closed jaws to quantify the benefit of the attenuation provided by the jaws. Results: The radioisotopes produced in the linac head have been identified as 187 W, 56 Mn, 24 Na and 28 Al, which have half-lives from between 2.3 min to 24 hours. The dose at the beam exit window following an 18 MV 2197 MU TBI beam delivery was 12.6 µSv in ten minutes. The dose rate at the TBI treatment couch 4.8 m away is a factor of ten lower. For a typical TBI delivered in six fractions each consisting of four beams and an annual patient load of 24, the annual dose estimate for a staff member at the treatment couch for ten minutes is 750 µSv. This can be further reduced by a factor of about twelve if the jaws are closed before entering the room, resulting in a dose estimate of 65 µSv. Conclusion: The dose resulting from the activation products for a representative TBI workload at our clinic of 24 patients per year is 750 µSv, which can be further reduced to 65 µSv by closing the jaws

  16. Antiepileptic drug prescribing before, during and after pregnancy: a study in seven European regions.

    Science.gov (United States)

    Charlton, Rachel; Garne, Ester; Wang, Hao; Klungsøyr, Kari; Jordan, Sue; Neville, Amanda; Pierini, Anna; Hansen, Anne; Engeland, Anders; Gini, Rosa; Thayer, Daniel; Bos, Jens; Puccini, Aurora; Nybo Andersen, Anne-Marie; Dolk, Helen; de Jong-van den Berg, Lolkje

    2015-11-01

    The aim of this study was to explore antiepileptic drug (AED) prescribing before, during and after pregnancy as recorded in seven population-based electronic healthcare databases. Databases in Denmark, Norway, the Netherlands, Italy (Emilia Romagna/Tuscany), Wales and the Clinical Practice Research Datalink, representing the rest of the UK, were accessed for the study. Women with a pregnancy starting and ending between 2004 and 2010, which ended in a delivery, were identified. AED prescriptions issued (UK) or dispensed (non-UK) at any time during pregnancy and the 6 months before and after pregnancy were identified in each of the databases. AED prescribing patterns were analysed, and the choice of AEDs and co-prescribing of folic acid were evaluated. In total, 978 957 women with 1 248 713 deliveries were identified. In all regions, AED prescribing declined during pregnancy and was lowest during the third trimester, before returning to pre-pregnancy levels by 6 months following delivery. For all deliveries, the prevalence of AED prescribing during pregnancy was 51 per 10 000 pregnancies (CI95 49-52%) and was lowest in the Netherlands (43/10 000; CI95 33-54%) and highest in Wales (60/10 000; CI95 54-66%). In Denmark, Norway and the two UK databases lamotrigine was the most commonly prescribed AED; whereas in the Italian and Dutch databases, carbamazepine, valproate and phenobarbital were most frequently prescribed. Few women prescribed with AEDs in the 3 months before pregnancy were co-prescribed with high-dose folic acid: ranging from 1.0% (CI95 0.3-1.8%) in Emilia Romagna to 33.5% (CI95 28.7-38.4%) in Wales. The country's differences in prescribing patterns may suggest different use, knowledge or interpretation of the scientific evidence base. The low co-prescribing of folic acid indicates that more needs to be done to better inform clinicians and women of childbearing age taking AEDs about the need to offer and receive complete preconception care

  17. Changing doctor prescribing behaviour

    DEFF Research Database (Denmark)

    Gill, P.S.; Mäkelä, M.; Vermeulen, K.M.

    1999-01-01

    Collaboration on Effective Professional Practice. This register is kept up to date by searching the following databases for reports of relevant research: DHSS-DATA; EMBASE; MEDLINE; SIGLE; Resource Database in Continuing Medical Education (1975-1994), along with bibliographies of related topics, hand searching......The aim of this overview was to identify interventions that change doctor prescribing behaviour and to derive conclusions for practice and further research. Relevant studies (indicating prescribing as a behaviour change) were located from a database of studies maintained by the Cochrane...... of key journals and personal contact with content area experts. Randomised controlled trials and non-equivalent group designs with pre- and post-intervention measures were included. Outcome measures were those used by the study authors. For each study we determined whether these were positive, negative...

  18. Accelerating an Ordered-Subset Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction with a Power Factor and Total Variation Minimization.

    Science.gov (United States)

    Huang, Hsuan-Ming; Hsiao, Ing-Tsung

    2016-01-01

    In recent years, there has been increased interest in low-dose X-ray cone beam computed tomography (CBCT) in many fields, including dentistry, guided radiotherapy and small animal imaging. Despite reducing the radiation dose, low-dose CBCT has not gained widespread acceptance in routine clinical practice. In addition to performing more evaluation studies, developing a fast and high-quality reconstruction algorithm is required. In this work, we propose an iterative reconstruction method that accelerates ordered-subsets (OS) reconstruction using a power factor. Furthermore, we combine it with the total-variation (TV) minimization method. Both simulation and phantom studies were conducted to evaluate the performance of the proposed method. Results show that the proposed method can accelerate conventional OS methods, greatly increase the convergence speed in early iterations. Moreover, applying the TV minimization to the power acceleration scheme can further improve the image quality while preserving the fast convergence rate.

  19. Comparison of therapy augmentation and deviation rates from the recommended once-daily dosing regimen between LDX and commonly prescribed long-acting stimulants for the treatment of ADHD in youth and adults.

    Science.gov (United States)

    Setyawan, Juliana; Hodgkins, Paul; Guérin, Annie; Gauthier, Geneviève; Cloutier, Martin; Wu, Eric; Erder, M Haim

    2013-10-01

    To compare therapy augmentation and deviation rates from the recommended once-daily dosing regimen in Attention Deficit Hyperactivity Disorder (ADHD) patients initiated on lisdexamfetamine (LDX) vs other once-daily Food and Drug Administration (FDA) approved stimulants. ADHD patients initiated on a long-acting ADHD stimulant medication (index medication) in/after 2007 were selected from a large U.S. administrative claims database. Patients were required to be persistent for ≥90 days and continuously enrolled in their healthcare plan for ≥12 months following treatment initiation date. Based on age and previous treatment status, patients were classified into treatment-naïve children and adolescents (6-17 years old), previously treated children and adolescents, treatment-naïve adults (≥18 years old), and previously treated adults. Furthermore, patients were classified into four mutually exclusive treatment groups, based on index medication: lisdexamfetamine (LDX), osmotic release methylphenidate hydrochloride long-acting (OROS MPH), other methylphenidate/dexmethylphenidate long-acting (MPH LA), and amphetamine/dextroamphetamine long-acting (AMPH LA). The average daily consumption was measured as the quantity of index medication supplied in the 12-month study period divided by the total number of days of supply. Therapy augmentation was defined as the use of another ADHD medication concomitantly with the index medication for ≥28 consecutive days. Therapy augmentation and deviation rates from the recommended once-daily dosing regimen were compared between treatment groups using multivariate logistic regression models. Compared to the other treatment groups, LDX patients were less likely to augment with another ADHD medication (range odds ratios [OR]; 1.28-3.30) and to deviate from the recommended once-daily dosing regimen (range OR; 1.73-4.55), except for previously treated adult patients, where therapy augmentation differences were not statistically

  20. Low-Dose (10-Gy) Total Skin Electron Beam Therapy for Cutaneous T-Cell Lymphoma: An Open Clinical Study and Pooled Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kamstrup, Maria R., E-mail: mkam0004@bbh.regionh.dk [Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen (Denmark); Gniadecki, Robert [Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen (Denmark); Iversen, Lars [Department of Dermatology, Aarhus University Hospital, Aarhus (Denmark); Skov, Lone [Department of Dermatology, Gentofte Hospital, University of Copenhagen, Copenhagen (Denmark); Petersen, Peter Meidahl [Department of Oncology and Hematology, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Loft, Annika [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Specht, Lena [Department of Oncology and Hematology, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark)

    2015-05-01

    Purpose: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. Methods and Materials: In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over <2.5 weeks, receiving a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. Results: The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. Conclusions: Low-dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT.

  1. TU-CD-304-04: Scanning Field Total Body Irradiation Using Dynamic Arc with Variable Dose Rate and Gantry Speed

    Energy Technology Data Exchange (ETDEWEB)

    Yi, B; Xu, H; Mutaf, Y; Prado, K [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: Enable a scanning field total body irradiation (TBI) technique, using dynamic arcs, which is biologically equivalent to a moving couch TBI. Methods: Patient is treated slightly above the floor and the treatment field scans across the patient by a moving gantry. MLC positions change during gantry motion to keep same field opening at the level of the treatment plane (170 cm). This is done to mimic the same geometry as the moving couch TBI technique which has been used in our institution for over 10 years. The dose rate and the gantry speed are determined considering a constant speed of the moving field, variations in SSD and slanted depths resulting from oblique gantry angles. An Eclipse (Varian) planning system is commissioned to accommodate the extended SSD. The dosimetric foundations of the technique have been thoroughly investigated using phantom measurements. Results: Dose uniformity better than 2% across 180 cm length at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Treatment range can be extended by increasing gantry range. No device such as a gravity-oriented compensator is needed to achieve a uniform dose. It is feasible to modify the dose distribution by adjusting the dose rate at each gantry angle to compensate for body thickness differences. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 100 MU/min. Conclusion: This novel yet transportable moving field technique enables TBI treatment in a small treatment room with less program development preparation than other techniques. Treatment length can be extended per need, and. MLC-based thickness compensation and partial lung blocking are also possible.

  2. The role of total dose in conservative surgery and radiation therapy for early stage breast cancer: is there a critical level?

    Energy Technology Data Exchange (ETDEWEB)

    White, Julia; Brown, Douglas; Gustafson, Greg; Chen, Peter; Matter, Richard; Cook, Carla; Martinez, Alvaro; Vicini, Frank A

    1995-07-01

    Purpose: Over the past several years, it has been our standard policy after breast conserving surgery to treat the entire breast to 45-50 Gy followed by a supplemental boost dose to the tumor bed to a minimum of 60 Gy with standard fractionation. We reviewed patients who received < 60 Gy to the tumor bed to identify any differences in recurrence rates in the breast. Materials and Methods: From 1/1/75 through 12/31/87, 443 consecutive patients diagnosed with stage I and II breast cancer (unilateral) were treated with conservative surgery and radiation therapy (CSRT) at William Beaumont Hospital. All patients underwent at least an excisional biopsy and 268 (60%) patients were re-excised. An ipsilateral axillary lymph node dissection was performed on 420 patients (95%). All patients received whole breast irradiation to 45-50 Gy. A supplemental boost dose was delivered to the tumor bed with either an implant, electrons, or photons in 404 (91%) patients. Median follow-up of surviving patients is 88 months. Results: Thirty-three patients of the 443 have suffered a failure in the treated breast for a 5 and 10 yr actuarial rate of local recurrence of 5 and 10%, respectively. Evaluation by total dose to the tumor bed is as follows: The distribution of patient's respective histology, tumor size, hormonal status, age, re-excision status, and adjuvant systemic therapy was similar among the dose groups. On multivariate analysis (Cox), in addition to total dose to tumor bed (p=0.002), the only other factor which was significantly associated with local recurrence was patient age {<=} 35 (p=0.002). Conclusions: Patients who receive {<=} 50 Gy to the tumor bed without careful attention to excisional status are at a significantly higher risk of local failure. This underlies the importance of supplementing the tumor bed dose after whole breast radiation therapy in those patients whose status of excision is not definitely known.

  3. Low-Dose Total Skin Electron Beam Therapy as a Debulking Agent for Cutaneous T-Cell Lymphoma: An open-label prospective phase II study

    DEFF Research Database (Denmark)

    Kamstrup, M R; Lindahl, Lise Maria; Gniadecki, R

    2012-01-01

    Background: Total skin electron beam therapy (TSEBT) is a powerful treatment for cutaneous T-cell lymphomas (CTCL). Based on the occurrence of relapses with low radiation doses, doses of 30-36 Gy are commonly used but most patients still eventually relapse and repeat treatment courses are limited...... due to the cumulative toxicity. Complete response rates are about 60-90% for T2-4 stages with a 5-year relapse-free survival of 10-25% for stages IB-III. Objectives: To evaluate prospectively the efficacy of low-dose TSEBT (10 Gy) in terms of complete cutaneous response rate, overall response rate...... and response duration in CTCL. Methods: Ten patients with stage IB-IV mycosis fungoides (MF) were treated in an open-label manner with 4 fractions of 1 Gy/week TSEB to a total skin dose of 10 Gy. Treatment responses were assessed at 1 and 3 months after treatment and subsequently at least every 6 months...

  4. Total dose behavior of partially depleted SOI dynamic threshold voltage MOS (DTMOS) for very low supply voltage applications (0.6 - 1 V)

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Musseau, O.; Leray, J.L.; Faynot, O.; Raynaud, C.; Pelloie, J.L.

    1999-01-01

    In this paper, we presented two DTMOS architectures processed with a partially depleted SOI technology. The first architecture, DTMOS without limiting transistor, is dedicated to ultra-low voltage applications, at 0.6 V. For 1V applications, the second architecture, DTMOS with limiting transistor, needs an additional transistor to limit the body-source diode current. The total dose irradiation of both DTMOS architectures induces no change of the drain current, but an increase of the body-source diode current. Total dose induced trapped charge in the buried oxide increases the body potential of the DTMOS transistor. It induces an increase of the current flow at the back interface of the silicon film. Irradiation of complex circuits using DTMOS transistors would lead to a degradation of the stand-by consumption. (authors)

  5. A reviewed technique for total body electron therapy using a Varian Clinac 2100C/D high dose rate treatment beam facility

    International Nuclear Information System (INIS)

    Oliver, L.D.; Xuereb, E.M.A.; Last, V.; Hunt, P.B.; Wilfert, A.

    1996-01-01

    Our (Royal North Shore Hospital) most recent linear accelerator acquisition is a Varian Clinac 2100C/D which has a high dose rate (approximately 25Gy per minute at 1 metre) total body electron option. We investigated the physical characteristics of the electron beam to develop a suitable method of treatment for total body electron therapy. The useful electron beam width is defined as 80cm above and below the reference height. Measurements of the electron dose received from the two angled electron beams showed a critical dependence on the gantry angles. The treatment protocol uses ten different patient angles, fractionated into directly opposing fields and treated seuqentially each day. A full cycle of treatment is completed in five days. (author)

  6. STUDY OF PRESCRIBING PATTERN OF ANTIMICROBIAL AGENTS IN SELECTED PATIENTS ATTENDING TERTIARY CARE HOSPITAL IN INDIA

    Directory of Open Access Journals (Sweden)

    Anjan Adhikari

    2013-06-01

    Full Text Available Antibiotics are the most commonly prescribed drugs in hospitals and their irrational use is one of the important factors for the development and spread of resistance. The objective of this study was to evaluate the antibiotic prescription pattern in the patient attending the tertiary care hospital. It was found that a total of 333 antibiotics where prescribed in 245 prescriptions. The average number of antibiotics per prescription was approximately1.4. The most commonly used antibiotics were moxifloxacin 19.5%, metronidazole 10.4%, amoxicillin + cloxacillin 10.2% and ciprofloxacin 6%. antibiotics were almost equally prescribed to both male and female. 45.5% of the antibiotics shows adherence with the National List of Essential Medicines of India. 76.6% of the antibiotics were single products while 23.4% were fixed dose combination. The most commonly used dosage forms were tablets (57%, drops (23.5% and creams (11.7%.57.3% were prescribed irrationally. Quinolones (48.2% and antifungals (21.5% were the most common types of prescribed antibiotics in which irrationality was found.

  7. The impact of pharmacy services on opioid prescribing in dental practice.

    Science.gov (United States)

    Stewart, Autumn; Zborovancik, Kelsey J; Stiely, Kara L

    To compare rates of dental opioid prescribing between periods of full and partial integration of pharmacy services and periods of no integration. This observational study used a retrospective chart review of opioid prescriptions written by dental providers practicing in a free dental clinic for the medically underserved over a period of 74 months. Pharmacy services were fully integrated into the practice model for 48 of the 74 months under study. During this time frame, all dental opioid orders required review by the pharmacy department before prescribing. Outcomes related to prescribing rates and errors were compared between groups, which were defined by the level of integrated pharmacy services. Demographic and prescription-specific data (drug name, dose, quantity, directions, professional designation of individual entering order) and clinic appointment data were collected and analyzed with the use of descriptive and inferential statistics. A total of 102 opioids were prescribed to 89 patients; hydrocodone-acetaminophen combination products were the most frequently used. Opioid prescribing rates were 5 times greater when pharmacy services were not integrated (P dental practice. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  8. Comparative study on skin dose measurement using MOSFET and TLD for pediatric patients with acute lymphatic leukemia.

    Science.gov (United States)

    Al-Mohammed, Huda I; Mahyoub, Fareed H; Moftah, Belal A

    2010-07-01

    The object of this study was to compare the difference of skin dose measured in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using metal oxide semiconductor field-effect transistors (mobile MOSFET dose verification system (TN-RD-70-W) and thermoluminescent dosimeters (TLD-100 chips, Harshaw/ Bicron, OH, USA). Because TLD has been the most-commonly used technique in the skin dose measurement of TBI, the aim of the present study is to prove the benefit of using the mobile MOSFET (metal oxide semiconductor field effect transistor) dosimeter, for entrance dose measurements during the total body irradiation (TBI) over thermoluminescent dosimeters (TLD). The measurements involved 10 pediatric patients ages between 3 and 14 years. Thermoluminescent dosimeters and MOSFET dosimetry were performed at 9 different anatomic sites on each patient. The present results show there is a variation between skin dose measured with MOSFET and TLD in all patients, and for every anatomic site selected, there is no significant difference in the dose delivered using MOSFET as compared to the prescribed dose. However, there is a significant difference for every anatomic site using TLD compared with either the prescribed dose or MOSFET. The results indicate that the dosimeter measurements using the MOSFET gave precise measurements of prescribed dose. However, TLD measurement showed significant increased skin dose of cGy as compared to either prescribed dose or MOSFET group. MOSFET dosimeters provide superior dose accuracy for skin dose measurement in TBI as compared with TLD.

  9. The effect of total body irradiation dose and chronic graft-versus-host disease on leukaemic relapse after allogeneic bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Frassoni, F; Bacigalupo, A [Ospedale San Martino (Italy). Centro Trapianti Midollo Osseo; Scarpati, D [Univ. di Genova (Italy). Ist. di Radiologia; and others

    1989-10-01

    One-hundred and five patients undergoing allo-geneic bone marrow transplantation (BMT) for acute myeloid leukaemia (AML) (n=61) and chronic myeloid leukaemia (n=44) were analysed for risk factors associated with relapse. All patients received marrow from an HLA identical sibling after preparation with cyclophosphamide 120 mg/kg and total body irradiation (TBI) 330 cGy on each of the three days prior to transplantation. A multivariate Cox analysis indicated that a lower TBI dose (less than 990 cGy) was the most significant factor associated with relapse and the second most important factor associated with recurrence of leukaemia was the absence of chronic graft-versus-host-disease (cGvHD). Actuarial relapse incidence was 62%, 28% and 18% for patients with no, limited or extensive chronic GvHD respectively. However, chronic GvHD had no significant impact on survival. Combined stratification for TBI dose and cGvHD showed that the dose effect of TBI on relapse was evident both in patients with and without cGvHD. Chronic GvHD influenced the risk of relapse only in patients receiving less than 990 cGy. These results suggest that a higher dose of TBI, within this schedule, produced long-term disease-free survival in the majority of AMLs and CMLs. Minor radiobiological side effects were experienced, but a small reduction of the dose may significantly increase the risk of relapse. (author).

  10. The effect of total body irradiation dose and chronic graft-versus-host disease on leukaemic relapse after allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Frassoni, F.; Bacigalupo, A.; Scarpati, D.

    1989-01-01

    One-hundred and five patients undergoing allo-geneic bone marrow transplantation (BMT) for acute myeloid leukaemia (AML) (n=61) and chronic myeloid leukaemia (n=44) were analysed for risk factors associated with relapse. All patients received marrow from an HLA identical sibling after preparation with cyclophosphamide 120 mg/kg and total body irradiation (TBI) 330 cGy on each of the three days prior to transplantation. A multivariate Cox analysis indicated that a lower TBI dose (less than 990 cGy) was the most significant factor associated with relapse and the second most important factor associated with recurrence of leukaemia was the absence of chronic graft-versus-host-disease (cGvHD). Actuarial relapse incidence was 62%, 28% and 18% for patients with no, limited or extensive chronic GvHD respectively. However, chronic GvHD had no significant impact on survival. Combined stratification for TBI dose and cGvHD showed that the dose effect of TBI on relapse was evident both in patients with and without cGvHD. Chronic GvHD influenced the risk of relapse only in patients receiving less than 990 cGy. These results suggest that a higher dose of TBI, within this schedule, produced long-term disease-free survival in the majority of AMLs and CMLs. Minor radiobiological side effects were experienced, but a small reduction of the dose may significantly increase the risk of relapse. (author)

  11. Total integrated dose testing of solid-state scientific CD4011, CD4013, and CD4060 devices by irradiation with CO-60 gamma rays

    Science.gov (United States)

    Dantas, A. R. V.; Gauthier, M. K.; Coss, J. R.

    1985-01-01

    The total integrated dose response of three CMOS devices manufactured by Solid State Scientific has been measured using CO-60 gamma rays. Key parameter measurements were made and compared for each device type. The data show that the CD4011, CD4013, and CD4060 produced by this manufacturers should not be used in any environments where radiation levels might exceed 1,000 rad(Si).

  12. The role of low-dose total body irradiation in treatment of non-Hodgkin's lymphoma: a new look at an old method

    International Nuclear Information System (INIS)

    Safwat, A.

    2000-01-01

    The use of low-dose total body irradiation (LTBI) in treatment of lymphomatous malignancies dates back to the 1920s. The usual practice was to give very low individual TBI fraction sizes (0. 1-0.25 Gy) several times a week to a total dose of 1.5-2 Gy. Despite this very low total dose, LTBI could induce long term remissions and was always as effective as the chemotherapy to which it was compared. In modem radiotherapy, LTBI is still a valid option in treatment of chronic lymphocytic leukaemia (CLL) and the advanced stages of indolent low-grade non-Hodgkin's lymphoma (NHL). Its use in the early stages of low-grade NHL is under investigation in a large multi-institutional trial. The efficacy of LTBI is believed to stem from three mechanisms, namely; immune-enhancement, induction of apoptosis, and the intrinsic hypersensitivity to low-radiation doses demonstrated in many cell lines and tumour systems. Thus, LTBI seems to provide 'alternative' mechanisms of action against cancer cells. This should encourage researchers to explore strategies that integrate LTBI in new and innovative experimental treatment protocols that explore the possible synergism between LTBI and chemotherapy, biological response modifiers and/or immunotherapy. The increased incidence of secondary leukaemia that occurs when LTBI is combined with alkylating agents and/or total lymphoid irradiation should be kept in mind when designing such protocols as it may limit the use of LTBI in highly curable diseases and young patients in whom long survival is expected. (author)

  13. Long-term brain structural magnetic resonance imaging and cognitive functioning in children treated for acute lymphoblastic leukemia with high-dose methotrexate chemotherapy alone or combined with CNS radiotherapy at reduced total dose to 12 Gy

    Energy Technology Data Exchange (ETDEWEB)

    Zajac-Spychala, Olga; Pilarczyk, Jakub; Derwich, Katarzyna; Wachowiak, Jacek [Poznan University of Medical Sciences, Department of Pediatric Oncology, Hematology and Transplantology, Poznan (Poland); Pawlak, Mikolaj A. [Poznan University of Medical Sciences, Department of Neurology and Cerebrovascular Disorders, Poznan (Poland); Karmelita-Katulska, Katarzyna [Poznan University of Medical Sciences, Department of Neuroradiology, Poznan (Poland)

    2017-02-15

    The aim of this study was to assess the long-term side effects of central nervous system prophylaxis (high-dose chemotherapy alone vs chemotherapy and CNS radiotherapy) according to the ALL IC-BFM 2002. Thirty-tree children aged 6.7-19.9 years have been studied. The control group consisted of 12 children newly diagnosed with acute lymphoblastic leukemia. We assessed subcortical gray matter volume using automatic MRI segmentation and cognitive performance to identify differences between two therapeutic schemes and patients prior to treatment. Patients treated with chemotherapy and CNS radiotherapy had smaller hippocampi than two other subgroups and lower IQ score than patients treated with chemotherapy alone. Both treated groups, whether with chemotherapy only or in combination with CNS radiotherapy, had significantly lower volumes of caudate nucleus and performed significantly worse on measures of verbal fluency in comparison with patients prior to treatment. There were no differences in the mean volumes of total white matter, total gray matter, thalamus, putamen, and amygdala between the studied groups. In all children treated according to the ALL IC-BFM 2002 with high-dose chemotherapy, both decreased volume of selected subcortical structures and cognitive impairment was observed, especially in children who received chemotherapy in combination with reduced dose CNS radiotherapy. In all children treated according to the ALL IC-BFM 2002 with high-dose chemotherapy, both decreased volume of selected subcortical structures and cognitive impairment were observed, especially in children who received chemotherapy in combination with CNS radiotherapy. (orig.)

  14. Long-term brain structural magnetic resonance imaging and cognitive functioning in children treated for acute lymphoblastic leukemia with high-dose methotrexate chemotherapy alone or combined with CNS radiotherapy at reduced total dose to 12 Gy

    International Nuclear Information System (INIS)

    Zajac-Spychala, Olga; Pilarczyk, Jakub; Derwich, Katarzyna; Wachowiak, Jacek; Pawlak, Mikolaj A.; Karmelita-Katulska, Katarzyna

    2017-01-01

    The aim of this study was to assess the long-term side effects of central nervous system prophylaxis (high-dose chemotherapy alone vs chemotherapy and CNS radiotherapy) according to the ALL IC-BFM 2002. Thirty-tree children aged 6.7-19.9 years have been studied. The control group consisted of 12 children newly diagnosed with acute lymphoblastic leukemia. We assessed subcortical gray matter volume using automatic MRI segmentation and cognitive performance to identify differences between two therapeutic schemes and patients prior to treatment. Patients treated with chemotherapy and CNS radiotherapy had smaller hippocampi than two other subgroups and lower IQ score than patients treated with chemotherapy alone. Both treated groups, whether with chemotherapy only or in combination with CNS radiotherapy, had significantly lower volumes of caudate nucleus and performed significantly worse on measures of verbal fluency in comparison with patients prior to treatment. There were no differences in the mean volumes of total white matter, total gray matter, thalamus, putamen, and amygdala between the studied groups. In all children treated according to the ALL IC-BFM 2002 with high-dose chemotherapy, both decreased volume of selected subcortical structures and cognitive impairment was observed, especially in children who received chemotherapy in combination with reduced dose CNS radiotherapy. In all children treated according to the ALL IC-BFM 2002 with high-dose chemotherapy, both decreased volume of selected subcortical structures and cognitive impairment were observed, especially in children who received chemotherapy in combination with CNS radiotherapy. (orig.)

  15. Clinical Usefulness between High Dose Radioiodine Therapy and Helicobacter Pylori Infection after Total Thyroidectomy due to Well Differentiated Thyroid Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Kuk No; Lim, Seok Tae; Moon, Eun Ha; Kim, Jin Suk; Jeong, Young Jin; Kim, Dong Wook; Jeong, Hwan Jeong; Sohn, Myung Hee [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of)

    2009-12-15

    Helicobacter (H) pylori infection has been considered the most important cause of gastritis, dyspepsia, and gastroduodenal ulcer. Radioiodine can be accumulated in the remaining thyroid tissue, salivary gland, and stomach. We investigated if the high radiation induced by radioiodine in the stomach after high dose radioiodine therapy (HD-RIT) is effective in the eradication of H. pylori infection. One hundred ninety nine patients (M:F=33:166, age 46.7{+-}12.3 years) who had HD-RIT (dose 159.1{+-}25.9 mCi, range 120-250 mCi) after thyroidectomy due to well differentiated thyroid cancer were enrolled. To detect H. pylori infection, the urea breath tests (UBT) were performed at 1 hour before HD-RIT and at 4 weeks after HD-RIT. The results of UBT were classified as positive ({>=}50 dpm) or negative (<50 dpm), and analyzed its values. Of 199 patients, 103 (51.8%) patients had positive UBT before HD-RIT. Of these, 80 patients had follow-up UBT after HD-RIT. Among them, 76 (95.0%) patients had persistent positive UBT and only 4 (5.0%) patients were changed negative UBT. Among 76 patients with persistent positive UBT, 26 (34.2%) patients had increased the values of follow-up UBT, 49 (64.5%) had decreased them, and 1 (1.3%) had shown the same value. The different values of UBT between before and after HD-RIT were 62{+-}66.1 dpm in increased one of follow-up UBT, and 153.3{+-}157.1 dpm in decreased one of follow-up UBT. We conclude that the radiation induced by HD-RIT is ineffective in the eradication of H. pylori infection. However, it could be influential the degree or distribution of H. pylori infection.

  16. Clinical Usefulness between High Dose Radioiodine Therapy and Helicobacter Pylori Infection after Total Thyroidectomy due to Well Differentiated Thyroid Cancer

    International Nuclear Information System (INIS)

    Yun, Kuk No; Lim, Seok Tae; Moon, Eun Ha; Kim, Jin Suk; Jeong, Young Jin; Kim, Dong Wook; Jeong, Hwan Jeong; Sohn, Myung Hee

    2009-01-01

    Helicobacter (H) pylori infection has been considered the most important cause of gastritis, dyspepsia, and gastroduodenal ulcer. Radioiodine can be accumulated in the remaining thyroid tissue, salivary gland, and stomach. We investigated if the high radiation induced by radioiodine in the stomach after high dose radioiodine therapy (HD-RIT) is effective in the eradication of H. pylori infection. One hundred ninety nine patients (M:F=33:166, age 46.7±12.3 years) who had HD-RIT (dose 159.1±25.9 mCi, range 120-250 mCi) after thyroidectomy due to well differentiated thyroid cancer were enrolled. To detect H. pylori infection, the urea breath tests (UBT) were performed at 1 hour before HD-RIT and at 4 weeks after HD-RIT. The results of UBT were classified as positive (≥50 dpm) or negative (<50 dpm), and analyzed its values. Of 199 patients, 103 (51.8%) patients had positive UBT before HD-RIT. Of these, 80 patients had follow-up UBT after HD-RIT. Among them, 76 (95.0%) patients had persistent positive UBT and only 4 (5.0%) patients were changed negative UBT. Among 76 patients with persistent positive UBT, 26 (34.2%) patients had increased the values of follow-up UBT, 49 (64.5%) had decreased them, and 1 (1.3%) had shown the same value. The different values of UBT between before and after HD-RIT were 62±66.1 dpm in increased one of follow-up UBT, and 153.3±157.1 dpm in decreased one of follow-up UBT. We conclude that the radiation induced by HD-RIT is ineffective in the eradication of H. pylori infection. However, it could be influential the degree or distribution of H. pylori infection

  17. A study of different dose calculation methods and the impact on the dose evaluation protocol in lung stereotactic radiation therapy

    International Nuclear Information System (INIS)

    Takada, Takahiro; Furuya, Tomohisa; Ozawa, Shuichi; Ito, Kana; Kurokawa, Chie; Karasawa, Kumiko; Miura, Kohei

    2008-01-01

    AAA (analytical anisotropic algorithm) dose calculation, which shows a better performance for heterogeneity correction, was tested for lung stereotactic radiation therapy (SBRT) in comparison to conventional PBC (pencil beam convolution method) to evaluate its impact on tumor dose parameters. Eleven lung SBRT patients who were treated with photon 4 MV beams in our department between April 2003 and February 2007 were reviewed. Clinical target volume (CTV) was delineated including the spicula region on planning CT images. Planning target volume (PTV) was defined by adding the internal target volume (ITV) and set-up margin (SM) of 5 mm from CTV, and then an multileaf collimator (MLC) penumbra margin of another 5 mm was also added. Six-port non-coplanar beams were employed, and a total prescribed dose of 48 Gy was defined at the isocenter point with four fractions. The entire treatment for an individual patient was completed within 8 days. Under the same prescribed dose, calculated dose distribution, dose volume histogram (DVH), and tumor dose parameters were compared between two dose calculation methods. In addition, the fractionated prescription dose was repeatedly scaled until the monitor units (MUs) calculated by AAA reached a level of MUs nearly identical to those achieved by PBC. AAA resulted in significantly less D95 (irradiation dose that included 95% volume of PTV) and minimal dose in PTV compared to PBC. After rescaling of each MU for each beam in the AAA plan, there was no revision of the isocenter of the prescribed dose required. However, when the PTV volume was less than 20 cc, a 4% lower prescription resulted in nearly identical MUs between AAA and PBC. The prescribed dose in AAA should be the same as that in PBC, if the dose is administered at the isocenter point. However, planners should compare DVHs and dose distributions between AAA and PBC for a small lung tumor with a PTV volume less than approximately 20 cc. (author)

  18. Impact of a warning CPOE system on the inappropriate pill splitting of prescribed medications in outpatients.

    Directory of Open Access Journals (Sweden)

    Chia-Chen Hsu

    Full Text Available Prescribing inappropriate pill splitting is not rare in clinical practice. To reduce inappropriate pill splitting, we developed an automatic warning system linked to a computerized physician order entry (CPOE system for special oral formulation drugs in outpatient settings. We examined the impact of the warning system on inappropriate prescribing of pill splitting and assess prescribers' responses to the warnings.Drugs with extended-release or enteric-coated formulations that were not originally intended to be split were recognized as "special oral formulations". A hard-stop system which could examine non-integer doses of drugs with special oral formulations, provide warnings to interrupt inappropriate prescriptions was integrated in CPOE in a medical center since June 2010. We designed an intervention study to compare the inappropriate splitting before and after the implementation of the warning system (baseline period 2010 January to May vs. intervention period 2010 June to 2011 August. During the intervention period, prescription changes in response to a warning were logged and analyzed.A total of 470,611 prescribed drug items with 34 different drugs with special oral formulations were prescribed in the study period. During the 15-month intervention period, 909 warnings for 26 different drugs were triggered among 354,523 prescribed drug items with special oral formulations. The warning rate of inappropriate splitting in the late intervention period was lower than those in baseline period (0.16% vs. 0.61%, incidence rate ratio 0.27, 95% CI 0.23-0.31, P<0.001. In respond to warnings, physicians had to make adjustments, of which the majority was changing to an unsplit pill (72.9%.The interruptive warning system could avoid the prescriptions with inappropriate pill splitting. Accordingly, physicians changed their behavior of prescribing special oral formulations regarding inappropriate pill splitting. We suggest the establishment of such system

  19. Prescribed fire research in Pennsylvania

    Science.gov (United States)

    Patrick Brose

    2009-01-01

    Prescribed fire in Pennsylvania is a relatively new forestry practice because of the State's adverse experience with highly destructive wildfires in the early 1900s. The recent introduction of prescribed fire raises a myriad of questions regarding its correct and safe use. This poster briefly describes the prescribed fire research projects of the Forestry Sciences...

  20. Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.

    Science.gov (United States)

    Mattar, Essam H; Hammad, Lina F; Al-Mohammed, Huda I

    2011-07-01

    Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dose during the treatment is important. Two kinds of metal oxide semiconductor field effect transistor (OneDose MOSFET and mobile MOSEFT) dosimeter are used during the treatment delivery to measure the skin dose to specific points and compare it with the target prescribed dose. The objective of this study was to compare the variation of skin dose in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using OneDose MOSFET detectors and Mobile MOSFET, and then compare both results with the target prescribed dose. The measurements involved 32 patient's (16 males, 16 females), aged between 14-30 years, with an average age of 22.41 years. One-Dose MOSFET and Mobile MOSFET dosimetry were performed at 10 different anatomical sites on every patient. The results showed there was no variation between skin dose measured with OneDose MOSFET and Mobile MOSFET in all patients. Furthermore, the results showed for every anatomical site selected there was no significant difference in the dose delivered using either OneDose MOSFET detector or Mobile MOSFET as compared to the prescribed dose. The study concludes that One-Dose MOSFET detectors and Mobile MOSFET both give a direct read-out immediately after the treatment; therefore both detectors are suitable options when measuring skin dose for total body irradiation treatment.

  1. Carbohydrate-to-insulin ratio is estimated from 300-400 divided by total daily insulin dose in type 1 diabetes patients who use the insulin pump.

    Science.gov (United States)

    Kuroda, Akio; Yasuda, Tetsuyuki; Takahara, Mitsuyoshi; Sakamoto, Fumie; Kasami, Ryuichi; Miyashita, Kazuyuki; Yoshida, Sumiko; Kondo, Eri; Aihara, Ken-ichi; Endo, Itsuro; Matsuoka, Taka-aki; Kaneto, Hideaki; Matsumoto, Toshio; Shimomura, Iichiro; Matsuhisa, Munehide

    2012-11-01

    To optimize insulin dose using insulin pump, basal and bolus insulin doses are widely calculated from total daily insulin dose (TDD). It is recommended that total daily basal insulin dose (TBD) is 50% of TDD and that the carbohydrate-to-insulin ratio (CIR) equals 500 divided by TDD. We recently reported that basal insulin requirement is approximately 30% of TDD. We therefore investigated CIR after adjustment of the proper basal insulin rate. Forty-five Japanese patients with type 1 diabetes were investigated during several weeks of hospitalization. The patients were served standard diabetes meals (25-30 kcal/kg of ideal body weight). Each meal omission was done to confirm basal insulin rate. Target blood glucose level was set at 100 and 150 mg/dL before and 2 h after each meal, respectively. After the basal insulin rate was fixed and target blood glucose levels were achieved, TBD, CIR, TDD, and their products were determined. Mean (±SD) blood glucose levels before and 2 h after meals were 121±47 and 150±61 mg/dL, respectively. TDD was 31.5±9.0 U, and TBD was 27.0±6.5% of TDD. CIR×TDD of breakfast was significantly lower than those of lunch and supper (288±73 vs. 408±92 and 387±83, respectively; Plunch and supper in type 1 diabetes patients. These results indicate that the insulin dose has been underestimated by using previously established calculations.

  2. PRESCRIBING PATTERN OF NON-STEROIDAL ANTI ...

    African Journals Online (AJOL)

    2015-03-01

    Mar 1, 2015 ... Design: A total of 3800 prescriptions containing. NSAIDs were analyzed for information on drug name, the number of NSAIDs per prescription, the presence of ACE inhibitors and diuretics alongside. NSAIDs and NSAIDs prescribed in generic or brand names. Results: The results showed that Aspirin was ...

  3. Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction

    Energy Technology Data Exchange (ETDEWEB)

    Wellenberg, R.H.H.; Streekstra, G.J.; Maas, M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Boomsma, M.F.; Osch, J.A.C. van [Department of Radiology, Zwolle (Netherlands); Vlassenbroek, A. [Philips Medical Systems, Brussels (Belgium); Milles, J. [Philips Medical Systems, Eindhoven (Netherlands); Edens, M.A. [Department of Innovation and Science, Zwolle (Netherlands); Slump, C.H. [University of Twente, MIRA Institute for Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2017-05-15

    To compare quantitative measures of image quality, in terms of CT number accuracy, noise, signal-to-noise-ratios (SNRs), and contrast-to-noise ratios (CNRs), at different dose levels with filtered-back-projection (FBP), iterative reconstruction (IR), and model-based iterative reconstruction (MBIR) alone and in combination with orthopedic metal artifact reduction (O-MAR) in a total hip arthroplasty (THA) phantom. Scans were acquired from high- to low-dose (CTDI{sub vol}: 40.0, 32.0, 24.0, 16.0, 8.0, and 4.0 mGy) at 120- and 140- kVp. Images were reconstructed using FBP, IR (iDose{sup 4} level 2, 4, and 6) and MBIR (IMR, level 1, 2, and 3) with and without O-MAR. CT number accuracy in Hounsfield Units (HU), noise or standard deviation, SNRs, and CNRs were analyzed. The IMR technique showed lower noise levels (p < 0.01), higher SNRs (p < 0.001) and CNRs (p < 0.001) compared with FBP and iDose{sup 4} in all acquisitions from high- to low-dose with constant CT numbers. O-MAR reduced noise (p < 0.01) and improved SNRs (p < 0.01) and CNRs (p < 0.001) while improving CT number accuracy only at a low dose. At the low dose of 4.0 mGy, IMR level 1, 2, and 3 showed 83%, 89%, and 95% lower noise values, a factor 6.0, 9.2, and 17.9 higher SNRs, and 5.7, 8.8, and 18.2 higher CNRs compared with FBP respectively. Based on quantitative analysis of CT number accuracy, noise values, SNRs, and CNRs, we conclude that the combined use of IMR and O-MAR enables a reduction in radiation dose of 83% compared with FBP and iDose{sup 4} in the CT imaging of a THA phantom. (orig.)

  4. A comparison of the effects of 2 doses of soy protein or casein on serum lipids, serum lipoproteins, and plasma total homocysteine in hypercholesterolemic subjects.

    Science.gov (United States)

    Tonstad, Serena; Smerud, Knut; Høie, Lars

    2002-07-01

    Studies have shown that soy protein reduces some atherogenic lipid and lipoprotein concentrations, although lipoprotein(a) concentrations may be increased. The dose response of soy protein has not been established; neither has its effect on plasma total homocysteine. Our objective was to evaluate the effect of 2 doses of soy protein on lipid, lipoprotein, and homocysteine concentrations. Four to 24 wk after being instructed to consume a lipid-lowering diet, 130 men and women with LDL-cholesterol concentrations > or = 4 mmol/L were studied during a parallel group trial in which 4 interventions were assigned randomly. Thirty grams isolated soy protein (ISP) and 10 g cotyledon fiber or 50 g ISP and 16.6 g cotyledon fiber or equivalent doses of casein and cellulose were consumed daily as a beverage for 16 wk. When the 2 groups who consumed ISP were compared with the 2 groups who consumed casein, the differences in the net changes from baseline to week 16 in the concentrations of LDL cholesterol and plasma total homocysteine were -0.26 mmol/L (95% CI: -0.43, -0.09 mmol/L; P = 0.01) and -0.8 micromol/L (-1.4, -0.2 micromol/L; P = 0.005), respectively. The effect of the ISP dose was not significant. There were no significant differences between the 2 ISP and the 2 casein groups in changes in lipoprotein(a), HDL-cholesterol, or triacylglycerol concentrations. Adding 30-50 g soy protein/d to a lipid-lowering diet significantly reduced LDL-cholesterol concentrations without increasing lipoprotein(a) concentrations. Plasma total homocysteine concentrations also decreased, suggesting a novel, possibly antiatherosclerotic effect.

  5. Serum total homocystein, folate and vitamin B12 levels and their correlation with antipsychotic drug doses in adult male patients with chronic schizophrenia.

    Science.gov (United States)

    Eren, Esin; Yeğin, Ayşenur; Yilmaz, Necat; Herken, Hasan

    2010-01-01

    Elevated blood levels of homocysteine (hCY) have been associated with schizophrenic male patients. However, controversy remains regarding the association between lowered plasma folate and vitamin B12, hyperhomocysteinemia, and schizophrenia. Sixty-six (66) male patients with chronic schizophrenia were investigated to test the hypotheses that alterations in Hcy, folate, and vitamin B12 levels might be related to the antipsychotic drug doses used in treatment. Serum total homocysteine, folic acid, and vitamin B12 levels were determined by chemiluminescence methods in both patients and control subjects. The patients were grouped according to the antipsychotic drug doses used in their treatment. Patients had higher homocysteine levels but they did not differ from controls in terms of folate and vitamin B12 levels. On the other hand, only folate levels were negatively correlated in the patient group treated with higher therapeutic doses of chlorpromazine equivalents (> 400 mg/day) compared to the patient group with lower doses (< 400 mg/day). Our findings show that higher typical antipsychotic drugs may play a role as modifiying factor for folate metabolism in chronic schizoprenic male patients.

  6. The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography

    Directory of Open Access Journals (Sweden)

    Toon Van Cauteren

    2017-01-01

    Full Text Available Objectives. To assess the impact of combining low-tube voltage acquisition with iterative reconstruction (IR techniques on the iodine dose in coronary CTA. Methods. Three minipigs underwent CCTA to compare a standard of care protocol with two alternative study protocols combining low-tube voltage and low iodine dose with IR. Image quality was evaluated objectively by the CT value, signal-to-noise ratio (SNR, and contrast-to-noise ratio (CNR in the main coronary arteries and aorta and subjectively by expert reading. Statistics were performed by Mann–Whitney U test and Chi-square analysis. Results. Despite reduced iodine dose, both study protocols maintained CT values, SNR, and CNR compared to the standard of care protocol. Expert readings confirmed these findings; all scans were perceived to be of at least diagnostically acceptable quality on all evaluated parameters allowing image interpretation. No statistical differences were observed (all p values > 0.11, except for streak artifacts (p=0.02 which were considered to be more severe, although acceptable, with the 80 kVp protocol. Conclusions. Reduced tube voltage in combination with IR allows a total iodine dose reduction between 37 and 50%, by using contrast media with low iodine concentrations of 200 and 160 mg I/mL, while maintaining image quality.

  7. Intraoperative Low-Dose Ketamine Infusion Reduces Acute Postoperative Pain Following Total Knee Replacement Surgery: A Prospective, Randomized Double-Blind Placebo-Controlled Trial

    International Nuclear Information System (INIS)

    Pelin Cengiz, P.; Gokcinar, D.; Karabeyoglu, I.; Topcu, H.; Cicek, G. S.; Gogus, N.

    2014-01-01

    Objective: To evaluate the effect of intraoperative low-dose ketamine with general anesthesia on postoperative pain after total knee replacement surgery. Study Design: A randomized, double-blind comparative study. Place and Duration of Study: Ankara Numune Training and Research Hospital, Turkey, from January and June 2011. Methodology: Sixty adults undergoing total knee arthroplasty were enrolled in this study. The patients were randomly allocated into two groups of equal size to receive either racemic ketamine infusion (6.25 g/kg/minute) or the same volume of saline. A visual analogue scale (VAS) was used to measure each patient's level of pain at 1, 3, 6, 12, and 24 hours after surgery. Time to first analgesic request, postoperative morphine consumption and the incidence of side effects were also recorded. Results: Low-dose ketamine infusion prolonged the time to first analgesic request. It also reduced postoperative cumulative morphine consumption at 1, 3, 6, 12, and 24 hours postsurgery (p < 0.001). Postoperative VAS scores were also significantly lower in the ketamine group than placebo, at all observation times. Incidences of side effects were similar in both study groups. Conclusion: Intraoperative continuous low-dose ketamine infusion reduced pain and postoperative analgesic consumption without affecting the incidence of side effects. (author)

  8. Intraoperative low-dose ketamine infusion reduces acute postoperative pain following total knee replacement surgery: a prospective, randomized double-blind placebo-controlled trial.

    Science.gov (United States)

    Cengiz, Pelin; Gokcinar, Derya; Karabeyoglu, Isil; Topcu, Hulya; Cicek, Gizem Selen; Gogus, Nermin

    2014-05-01

    To evaluate the effect of intraoperative low-dose ketamine with general anesthesia on postoperative pain after total knee replacement surgery. A randomized, double-blind comparative study. Ankara Numune Training and Research Hospital, Turkey, from January and June 2011. Sixty adults undergoing total knee arthroplasty were enrolled in this study. The patients were randomly allocated into two groups of equal size to receive either racemic ketamine infusion (6 μg/kg/minute) or the same volume of saline. A visual analogue scale (VAS) was used to measure each patient's level of pain at 1, 3, 6, 12, and 24 hours after surgery. Time to first analgesic request, postoperative morphine consumption and the incidence of side effects were also recorded. Low-dose ketamine infusion prolonged the time to first analgesic request. It also reduced postoperative cumulative morphine consumption at 1, 3, 6, 12, and 24 hours postsurgery (p < 0.001). Postoperative VAS scores were also significantly lower in the ketamine group than placebo, at all observation times. Incidences of side effects were similar in both study groups. Intraoperative continuous low-dose ketamine infusion reduced pain and postoperative analgesic consumption without affecting the incidence of side effects.

  9. Analgesic and sedative effects of perioperative gabapentin in total knee arthroplasty A randomized, double-blind, placebo-controlled, dose-finding study

    DEFF Research Database (Denmark)

    Lunn, Troels Haxholdt; Husted, Henrik; Laursen, Mogens Berg

    2015-01-01

    (1:1:1) to either gabapentin 1300 mg/d (group A), gabapentin 900 mg/d (group B), or placebo (group C) daily from 2 hours preoperatively to postoperative day 6 in addition to a standardized multimodal analgesic regime. The primary outcome was pain upon ambulation 24 hours after surgery......Gabapentin has shown acute postoperative analgesic effects, but the optimal dose and procedure-specific benefits vs harm have not been clarified. In this randomized, double-blind, placebo-controlled dose-finding study, 300 opioid-naive patients scheduled for total knee arthroplasty were randomized......, and the secondary outcome was sedation 6 hours after surgery. Other outcomes were overall pain during well-defined mobilizations and at rest and sedation during the first 48 hours and from days 2-6, morphine use, anxiety, depression, sleep quality, and nausea, vomiting, dizziness, concentration difficulty, headache...

  10. Radiation therapy in the management of symptomatic bone metastases: the effect of total dose and histology on pain relief and response duration

    International Nuclear Information System (INIS)

    Arcangeli, Giorgio; Giovinazzo, Giuseppe; Saracino, Biancamaria; D'Angelo, Luciano; Giannarelli, Diana; Arcangeli, Giancarlo; Micheli, Adriana

    1998-01-01

    the several ranges of total dose delivered to the painful metastases, with 81%, 65%, and 46% complete relief rates in the 40-46 Gy, 30-36 Gy (p 0.03), and 8-28 Gy (p = 0.0001) dose ranges respectively. A straight correlation between total dose and complete pain relief was confirmed by the curve calculated by the logistic model which shows that doses of 30 Gy or more are necessary to achieve complete pain relief in 70% or more of bone metastases. This correlation holds also for the duration of pain control, as shown by the actuarial analysis of time to pain progression. Multivariate analyses, with complete pain relief and time to pain progression as endpoints show a highly significant effect of radiation dose (p = 0.0007) and performance status (p = 0.003), with lower rates of complete pain relief and shorter time to pain progression observed after smaller radiation total doses or higher Eastern Cooperative Oncology Group (ECOG) scores. Conclusion: Although single-dose or short course irradiation is an attractive treatment in reducing the number of multiple visits to radiotherapy departments for patients with painful bone metastases, it is nevertheless clear that aggressive protracted treatments seem to offer significant advantages especially for patients in whom the expected life span is not short

  11. Use of BEIR V and UNSCEAR 1988 in radiation risk assessment: Lifetime total cancer mortality risk estimates at low doses and low dose rates for low-LET radiation

    International Nuclear Information System (INIS)

    1992-12-01

    In November 1986, the Department of Defense (DoD) asked the Committee on Interagency Radiation Research and Policy Coordination (CIRRPC) to develop a coordinated Federal position on risk assessment for low levels of ionizing radiation. Since Federal risk assessment activities are based primarily on the scientific data and analyses in authoritative review documents prepared by groups like the National Academy of Sciences' Committee on the Biological Effects of Ionizing Radiation (BEIR), the National Council on Radiation Protection and Measurements (NCRP) and the United Nations' Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), DoD proposed that the CIRRPC Science Panel undertake the task of providing coordinated interagency positions on the use of information in the reports of such groups. The practice has been for individual Federal agencies to interpret and decide independently how to use the information provided in such reports. As a result of its deliberations, the Subpanel recommends two nominal risk estimates for lifetime total cancer mortality following whole-body exposure to low levels of low-LET ionizing radiation, one for the general population and one for the working-age population (see Section II). The recommended risk estimates reflect the general agreement of information in BEIR V and UNSCEAR 1988 for total cancer mortality. The Subpanel's risk estimates and associated statements are intended to meet the needs of the Federal agencies for: (a) values that are current; (b) values that are relevant to the low-dose and low dose-rate ionizing radiation exposures principally encountered in carrying out Federal responsibilities; (c) a statement of the change in the estimates of lifetime total cancer mortality relative to estimates in previous authoritative review documents; and (d) a practical statement on the scientific uncertainty associated with applying the lifetime total cancer mortality values at very low doses

  12. SU-E-T-501: Normal Tissue Toxicities of Pulsed Low Dose Rate Radiotherapy and Conventional Radiotherapy: An in Vivo Total Body Irradiation Study

    Energy Technology Data Exchange (ETDEWEB)

    Cvetkovic, D; Zhang, P; Wang, B; Chen, L; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2014-06-01

    Purpose: Pulsed low dose rate radiotherapy (PLDR) is a re-irradiation technique for therapy of recurrent cancers. We have previously shown a significant difference in the weight and survival time between the mice treated with conventional radiotherapy (CRT) and PLDR using total body irradiation (TBI). The purpose of this study was to investigate the in vivo effects of PLDR on normal mouse tissues.Materials and Methods: Twenty two male BALB/c nude mice, 4 months of age, were randomly assigned into a PLDR group (n=10), a CRT group (n=10), and a non-irradiated control group (n=2). The Siemens Artiste accelerator with 6 MV photon beams was used. The mice received a total of 18Gy in 3 fractions with a 20day interval. The CRT group received the 6Gy dose continuously at a dose rate of 300 MU/min. The PLDR group was irradiated with 0.2Gyx20 pulses with a 3min interval between the pulses. The mice were weighed thrice weekly and sacrificed 2 weeks after the last treatment. Brain, heart, lung, liver, spleen, gastrointestinal, urinary and reproductive organs, and sternal bone marrow were removed, formalin-fixed, paraffin-embedded and stained with H and E. Morphological changes were observed under a microscope. Results: Histopathological examination revealed atrophy in several irradiated organs. The degree of atrophy was mild to moderate in the PLDR group, but severe in the CRT group. The most pronounced morphological abnormalities were in the immune and hematopoietic systems, namely spleen and bone marrow. Brain hemorrhage was seen in the CRT group, but not in the PLDR group. Conclusions: Our results showed that PLDR induced less toxicity in the normal mouse tissues than conventional radiotherapy for the same dose and regimen. Considering that PLDR produces equivalent tumor control as conventional radiotherapy, it would be a good modality for treatment of recurrent cancers.

  13. Comparison of the effects of three different Baccaurea angulata whole fruit juice doses on plasma, aorta and liver MDA levels, antioxidant enzymes and total antioxidant capacity.

    Science.gov (United States)

    Ibrahim, Muhammad; Mikail, Maryam Abimbola; Ahmed, Idris Adewale; Hazali, Norazlanshah; Abdul Rasad, Mohammad Syaiful Bahari; Abdul Ghani, Radiah; Hashim, Ridzwan; Arief, Solachuddin Jahuari; Md Isa, Muhammad Lokman; Draman, Samsul

    2017-05-17

    Baccaurea angulata (common names: belimbing dayak or belimbing hutan) is a Malaysian underutilized fruit. The preliminary work on B. angulata fruit juice showed that it possesses antioxidant properties. Therefore, further work is needed to confirm the efficacy and proper dosage of B. angulata as a potential natural antioxidant. The present study was thus carried out to compare the effects of three different B. angulata whole fruit (WF) juice doses administered at nutritional doses of 0.50, 1.00 and 1.50 ml/kg/day on plasma, aorta and liver malondialdehyde (MDA) levels, antioxidant enzymes (superoxide dismutase, glutathione peroxidase and catalase) as well as total antioxidant capacity in rabbits fed high-cholesterol diet. Thirty-five male rabbits of New Zealand strain were randomly assigned to seven groups. For 12 weeks, group CH was fed 1% cholesterol diet only; group C1 was fed 1% cholesterol diet and 0.50 ml/kg/day B. angulata WF juice; group C2 was fed 1% cholesterol diet and 1.00 ml/kg/day B. angulata WF juice; group C3 was fed 1% cholesterol diet and 1.50 ml/kg/day B. angulata WF juice; group N was fed standard pellet only; group N1 was fed standard pellet and 0.50 ml/kg/day B. angulata WF juice; and group N2 was fed standard pellet and 1.00 ml/kg/day B. angulata WF juice. The three doses reduced the formation of MDA and enhanced the expression of endogenous antioxidant enzymes. The highest dose used (1.50 ml/kg/day) was, however, seen as the most potent. Higher doses of B. angulata juice exerted better antioxidant activity.

  14. Evaluation of the appropriate use of commonly prescribed fluoroquinolones and the risk of dysglycemia

    Science.gov (United States)

    Kabbara, Wissam K; Ramadan, Wijdan H; Rahbany, Peggy; Al-Natour, Souhaila

    2015-01-01

    Background Fluoroquinolones are among the most widely prescribed antibiotics. However, concerns about increasing resistant microorganisms and the risk of dysglycemia associated with the use of these agents have emerged. Objective The primary objective of the study was to evaluate the appropriate use of commonly prescribed fluoroquinolones, including appropriate indication, dose, dose adjustment in renal impairment, and duration of treatment. The secondary objective was to investigate the dysglycemic effect of fluoroquinolone use (hypoglycemia and/or hyperglycemia) in diabetic and nondiabetic patients. Methods A prospective observational study at a teaching hospital in Lebanon was conducted over a 6-month period. A total of 118 patients receiving broad-spectrum fluoroquinolones (levofloxacin, ciprofloxacin, and moxifloxacin) were identified. Patients were mainly recruited from internal medicine floors and intensive care units. Results The final percentage for the appropriate indication, dose, and duration of fluoroquinolone therapy was 93.2%, 74.6%, and 57.6%, respectively. A total of 57.1% of the patients did not receive the appropriate dose adjustment according to their level of renal impairment. In addition, dysglycemia occurred in both diabetic and nondiabetic patients. Dysglycemia was more frequently encountered with ciprofloxacin (50.0%), followed by levofloxacin (42.4%) and moxifloxacin (7.6%). Hyperglycemia was more common than hypoglycemia in all groups. The highest incidence of hyperglycemia occurred with levofloxacin (70.0%), followed by ciprofloxacin (39.0%) and moxifloxacin (33.3%). In contrast, hypoglycemia did not occur in the ciprofloxacin group, but it was more common with moxifloxacin (11.1%) and levofloxacin (6.0%). Conclusion The major clinical interventions for the future will adjust the dose and duration of therapy with commonly prescribed fluoroquinolones. The incidence of hypoglycemia was less common than hyperglycemia. PMID:25960658

  15. Allogeneic marrow transplantation following cyclophosphamide and escalating doses of hyperfractionated total body irradiation in patients with advanced lymphoid malignancies: a phase I/II trial

    International Nuclear Information System (INIS)

    Demirer, Taner; Petersen, Finn B.; Appelbaum, Frederick R.; Barnett, Todd A.; Sanders, Jean; Deeg, H. Joachim; Storb, Rainer; Doney, Kristine; Bensinger, William I.; Shannon-Dorcy, Kathleen; Buckner, C. Dean

    1995-01-01

    Purpose: To define the maximum tolerated dose (MTD) of unshielded total body irradiation (TBI) delivered from dual 60 C sources at an exposure rate of 0.08 Gy/min and given in thrice daily fractions of 1.2 Gy in patients with advanced lymphoid malignancies. Methods and Materials: Forty-four patients with a median age of 28 (range 6-48) years were entered into a Phase I/II study. All patients received cyclophosphamide (CY), 120 mg/kg administered over 2 days before TBI. Marrow from human leukocyte antigen (HLA) identical siblings was infused following the last dose of TBI. An escalation-deescalation schema designed to not exceed an incidence of 25% of Grade 3-4 regimen-related toxicities (RRTs) was used. The first dose level tested was 13.2 Gy followed by 14.4 Gy. Results: None of the four patients at the dose level of 13.2 Gy developed Grade 3-4 RRT. Two of the first eight patients receiving 14.4 Gy developed Grade 3-4 RRT, establishing this as the MTD. An additional 32 patients were evaluated at the 14.4 Gy level to confirm these initial observations. Of 40 patients receiving 14.4 Gy, 13 (32.5%) developed Grade 3-4 RRTs; 46% in adults and 12% in children. The primary dose limiting toxicity was Grade 3-4 hepatic toxicity, which occurred in 12.5% of patients. Noninfectious Grade 3-4 interstitial pneumonia syndrome occurred in 5% of patients. The actuarial probabilities of event-free survival, relapse, and nonrelapse mortality at 2 years were 0.10, 0.81, and 0.47, respectively, for patients who received 14.4 Gy of TBI. Conclusions: The outcome for patients receiving 14.4 Gy of TBI was not different from previous studies of other CY and TBI regimens in patients with advanced lymphoid malignancies. These data showed that the incidence of Grade 3-4 RRTs in adults was greater than the 25% maximum set as the goal of this study, suggesting that 13.2 Gy is a more appropriate dose of TBI for adults, while 14.4 Gy is an appropriate dose for children

  16. Social determinants of prescribed and non-prescribed medicine use

    Directory of Open Access Journals (Sweden)

    García-Altés Anna

    2010-05-01

    Full Text Available Abstract Background The aim of the present study was to describe the use of prescribed and non prescribed medicines in a non-institutionalised population older than 15 years of an urban area during the year 2000, in terms of age and gender, social class, employment status and type of Primary Health Care. Methods Cross-sectional study. Information came from the 2000 Barcelona Health Interview Survey. The indicators used were the prevalence of use of prescribed and non-prescribed medicines in the two weeks prior to the interview. Descriptive analyses, bivariate and multivariate logistic regression analyses were carried out. Results More women than men took medicines (75.8% vs. 60% respectively. The prevalence of use of prescribed medicines increased with age while the prevalence of non-prescribed use decreased. These age differences are smaller among those with poor perceived health. In terms of social class, a higher percentage of men with good health in the more advantaged classes took non-prescribed medicines compared with disadvantaged classes (38.7% vs 31.8%. In contrast, among the group with poor health, more people from the more advantaged classes took prescribed medicines, compared with disadvantaged classes (51.4% vs 33.3%. A higher proportion of people who were either retired, unemployed or students, with good health, used prescribed medicines. Conclusion This study shows that beside health needs, there are social determinants affecting medicine consumption in the city of Barcelona.

  17. Genistein protects against biomarkers of delayed lung sequelae in mice surviving high-dose total body irradiation

    International Nuclear Information System (INIS)

    Day, R.M.; Barshishat-Kupper, M.; Mog, S.R.; Mccart, E.A.; Prasanna, P.G.S.; Landauer, M.R.; Davis, T.A.

    2008-01-01

    The effects of genistein on 30-day survival and delayed lung injury were examined in C57BL/6J female mice. A single subcutaneous injection of vehicle (PEG-400) or genistein (200 mg/kg) was administered 24 h before total body irradiation (7.75 Gy 60 Co, 0.6 Gy/min). Experimental groups were: No treatment+Sham (NC), Vehicle+Sham (VC), Genistein+Sham (GC), Radiation only (NR), Vehicle+Radiation (VR), Genistein+Radiation (GR). Thirty-day survivals after 7.75 Gy were: NR 23%, VR 53%, and GR 92%, indicating significant protection from acute radiation injury by genistein. Genistein also mitigated radiation-induced weight loss on days 13-28 postirradiation. First generation lung fibroblasts were analyzed for micronuclei 24 h postirradiation. Fibroblasts from the lungs of GR-treated mice had significantly reduced micronuclei compared with NR mice. Collagen deposition was examined by histochemical staining. At 90 days postirradiation one half of the untreated and vehicle irradiated mice had focal distributions of small collagen-rich plaques in the lungs, whereas all of the genistein-treated animals had morphologically normal lungs. Radiation reduced the expression of COX-2, transforming growth factor-β receptor (TGFβR) I and II at 90 days after irradiation. Genistein prevented the reduction in TGFβRI. However, by 180 days postirradiation, these proteins normalized in all groups. These results demonstrate that genistein protects against acute radiation-induced mortality in female mice and that GR-treated mice have reduced lung damage compared to NR or VR. These data suggest that genistein is protective against a range of radiation injuries. (author)

  18. Genistein Protects Against Biomarkers of Delayed Lung Sequelae in Mice Surviving High-Dose Total Body Irradiation

    Science.gov (United States)

    DAY, Regina M.; BARSHISHAT-KUPPER, Michal; MOG, Steven R.; MCCART, Elizabeth A.; PRASANNA, P. G. S.; DAVIS, Thomas A.; LANDAUER, Michael R.

    2008-01-01

    The effects of genistein on 30-day survival and delayed lung injury were examined in C57BL/6J female mice. A single subcutaneous injection of vehicle (PEG-400) or genistein (200 mg/kg) was administered 24 h before total body irradiation (7.75 Gy 60Co, 0.6 Gy/min). Experimental groups were: No treatment + Sham (NC), Vehicle + Sham (VC), Genistein + Sham (GC), Radiation only (NR), Vehicle + Radiation (VR), Genistein + Radiation (GR). Thirty-day survivals after 7.75 Gy were: NR 23%, VR 53%, and GR 92%, indicating significant protection from acute radiation injury by genistein. Genistein also mitigated radiation-induced weight loss on days 13–28 postirradiation. First generation lung fibroblasts were analyzed for micronuclei 24 h postirradiation. Fibroblasts from the lungs of GR-treated mice had significantly reduced micronuclei compared with NR mice. Collagen deposition was examined by histochemical staining. At 90 days postirradiation one half of the untreated and vehicle irradiated mice had focal distributions of small collagen-rich plaques in the lungs, whereas all of the genistein-treated animals had morphologically normal lungs. Radiation reduced the expression of COX-2, transforming growth factor-β receptor (TGFβR) I and II at 90 days after irradiation. Genistein prevented the reduction in TGFβRI. However, by 180 days postirradiation, these proteins normalized in all groups. These results demonstrate that genistein protects against acute radiation-induced mortality in female mice and that GR-treated mice have reduced lung damage compared to NR or VR. These data suggest that genistein is protective against a range of radiation injuries. PMID:18434686

  19. Antipsychotic prescribing in older people.

    Science.gov (United States)

    Neil, Wendy; Curran, Stephen; Wattis, John

    2003-09-01

    Antipsychotic medications have made a significant contribution to the care of the mentally ill people over the past 50 years, with good evidence that both typical and atypical agents are effective in the treatment of schizophrenia and related conditions. In addition they are widely used to good effect in other disorders including psychotic depression, dementia and delirium. Both typical and atypical agents may cause severe side-effects and, in the elderly in particular, there is an increased propensity for drug interactions. If used with care, antipsychotics are usually well tolerated, especially the atypical drugs. Although antipsychotics are effective at reducing psychotic symptoms their limitations should be recognised. They do not 'cure' the underlying illness, and the management of psychotic and behavioural symptoms must take into consideration treatment of physical illness as well as psychosocial interventions. In addition, the antipsychotic effect may take one to two weeks to be evident so doses should not be increased too rapidly. Often small doses are effective in the elderly if they are given sufficient time to work. As our understanding of the mechanisms of psychosis improves it is hoped that new drugs will be developed with novel mechanisms of action with improved efficacy and reduced side-effects. There are several drugs in development, some sharing similarities to currently available agents whilst others have novel mechanisms of actions involving glutamate and nicotinic receptors. Pharmacogenetics is also likely to be increasingly important over the next few years. As the genetic basis of many psychiatric disorders becomes more clearly established it is likely that drugs specifically designed for particular sub-groups of receptors will be developed. Finally, although the pharmacological treatment of psychotic disorders in younger people has been given considerable attention, there is a paucity of good quality research on antipsychotic drug use in

  20. 75 deaths in asthmatics prescribed home nebulisers.

    Science.gov (United States)

    Sears, M R; Rea, H H; Fenwick, J; Gillies, A J; Holst, P E; O'Donnell, T V; Rothwell, R P

    1987-02-21

    The circumstances surrounding the deaths of 75 asthmatic patients who had been prescribed a domiciliary nebuliser driven by an air compressor pump for administration of high dose beta sympathomimetic drugs were investigated as part of the New Zealand national asthma mortality study. Death was judged unavoidable in 19 patients who seemed to have precipitous attacks despite apparently good long term management. Delays in seeking medical help because of overreliance on beta agonist delivered by nebuliser were evident in 12 cases and possible in a further 11, but these represented only 8% of the 271 verified deaths from asthma in New Zealanders aged under 70 during the period. Evidence for direct toxicity of high dose beta agonist was not found. Nevertheless, the absence of serum potassium and theophylline concentrations and of electrocardiographic monitoring in the period immediately preceding death precluded firm conclusions whether arrhythmias might have occurred due to these factors rather than to hypoxia alone. In most patients prescribed domiciliary nebulisers death was associated with deficiencies in long term and short term care similar to those seen in patients without nebulisers. Discretion in prescribing home nebulisers, greater use of other appropriate drugs, including adequate corticosteroids, and careful supervision and instruction of patients taking beta agonist by nebuliser should help to reduce the mortality from asthma.

  1. Total ionizing dose radiation hardness of the ATLAS MDT-ASD and the HP-Agilent 0.5 um CMOS process

    CERN Document Server

    Posch, C

    2002-01-01

    A total ionizing dose (TID) test of the MDT-ASD, the ATLAS MDT front-end chip has been performed at the Harvard Cyclotron Lab. The MDT-ASD is an 8-channel drift tube read-out ASIC fabricated in a commercial 0.5 um CMOS process (AMOS14TB). The accumulated TID at the end of the test was 300 krad, delivered by 160 MeV protons at a rate of approximately 70 rad/sec. All 10 irradiated chips retained their full functionality and performance and showed only irrelevantly small changes in device parameters. As the total accumulated dose is substantially higher than the relevant ATLAS Radiation Tolerance Criteria (RTCtid), the results of this test indicate that MDT-ASD meets the ATLAS TID radiation hardness requirements. In addition, the results of this test correspond well with results of a 30 keV gamma TID irradiation test performed by us on an earlier prototype at the CERN x-ray facility as well as with results of other irradiation test on this process found in literature.

  2. Muscle-invasive bladder cancer treated with external beam radiation: influence of total dose, overall treatment time, and treatment interruption on local control

    International Nuclear Information System (INIS)

    Moonen, L.; Voet, H. van der; Nijs, R. de; Horenblas, S.; Hart, A.A.M.; Bartelink, H.

    1998-01-01

    Purpose: To evaluate and eventually quantify a possible influence of tumor proliferation during the external radiation course on local control in muscle invasive bladder cancer. Methods and Materials: The influence of total dose, overall treatment time, and treatment interruption has retrospectively been analyzed in a series of 379 patients with nonmetastasized, muscle-invasive transitional cell carcinoma of the urinary bladder. All patients received external beam radiotherapy at the Netherlands Cancer Institute between 1977 and 1990. Total dose varied between 50 and 75 Gy with a mean of 60.5 Gy and a median of 60.4 Gy. Overall treatment time varied between 20 and 270 days with a mean of 49 days and a median of 41 days. Number of fractions varied between 17 and 36 with a mean of 27 and a median of 26. Two hundred and forty-four patients had a continuous radiation course, whereas 135 had an intended split course or an unintended treatment interruption. Median follow-up was 22 months for all patients and 82 months for the 30 patients still alive at last follow-up. A stepwise procedure using proportional hazard regression has been used to identify prognostic treatment factors with respect to local recurrence as sole first recurrence. Results: One hundred and thirty-six patients experienced a local recurrence and 120 of these occurred before regional or distant metastases. The actuarial local control rate was 40.3% at 5 years and 32.3% at 10 years. In a multivariate analysis total dose showed a significant association with local control (p 0.0039), however in a markedly nonlinear way. In fact only those patients treated with a dose below 57.5 Gy had a significant higher bladder relapse rate, whereas no difference in relapse rate was found among patients treated with doses above 57.5 Gy. This remained the case even after adjustment for overall treatment time and all significant tumor and patient characteristics. The Normalized Tumor Dose (NTD) (α/β = 10) and NTD (

  3. Reduced-intensity conditioning regimen using low-dose total body irradiation before allogeneic transplant for hematologic malignancies: Experience from the European Group for Blood and Marrow Transplantation

    International Nuclear Information System (INIS)

    Belkacemi, Yazid; Labopin, Myriam; Hennequin, Christophe; Hoffstetter, Sylvette; Mungai, Raffaello; Wygoda, Marc; Lundell, Marie; Finke, Jurgen; Aktinson, Chris; Lorchel, Frederic; Durdux, Catherine; Basara, Nadezda

    2007-01-01

    Purpose: The high rate of toxicity is the limitation of myelobalative regimens before allogeneic transplantation. A reduced intensity regimen can allow engraftment of stem cells and subsequent transfer of immune cells for the induction of a graft-vs.-tumor reaction. Methods and Materials: The data from 130 patients (80 males and 50 females) treated between 1998 and 2003 for various hematologic malignancies were analyzed. The median patient age was 50 years (range, 3-72 years). Allogeneic transplantation using peripheral blood or bone marrow, or both, was performed in 104 (82%), 22 (17%), and 4 (3%) patients, respectively, from HLA identical sibling donors (n = 93, 72%), matched unrelated donors (n = 23, 18%), mismatched related donors (4%), or mismatched unrelated donors (6%). Total body irradiation (TBI) at a dose of 2 Gy delivered in one fraction was given to 101 patients (78%), and a total dose of 4-6 Gy was given in 29 (22%) patients. The median dose rate was 14.3 cGy/min (range, 6-16.4). Results: After a median follow-up period of 20 months (range, 1-62 months), engraftment was obtained in 122 patients (94%). Acute graft-vs.-host disease of Grade 2 or worse was observed in 37% of patients. Multivariate analysis showed three favorable independent factors for event-free survival: HLA identical sibling donor (p < 0.0001; relative risk [RR], 0.15), complete remission (p < 0.0001; RR, 3.08), and female donor to male patient (p = 0.006; RR 2.43). For relapse, the two favorable prognostic factors were complete remission (p < 0.0001, RR 0.11) and HLA identical sibling donor (p = 0.0007; RR 3.59). Conclusions: In this multicenter study, we confirmed high rates of engraftment and chimerism after the reduced intensity regimen. Our results are comparable to those previously reported. Radiation parameters seem to have no impact on outcome. However, the lack of a statistically significant difference in terms of dose rate may have been due, in part, to the small population

  4. Prescribing antibiotics in general practice:

    DEFF Research Database (Denmark)

    Sydenham, Rikke Vognbjerg; Pedersen, Line Bjørnskov; Plejdrup Hansen, Malene

    Objectives The majority of antibiotics are prescribed from general practice. The use of broad-spectrum antibiotics increases the risk of development of bacteria resistant to antibiotic treatment. In spite of guidelines aiming to minimize the use of broad-spectrum antibiotics we see an increase...... in the use of these agents. The overall aim of the project is to explore factors influencing the decision process and the prescribing behaviour of the GPs when prescribing antibiotics. We will study the impact of microbiological testing on the choice of antibiotic. Furthermore the project will explore how...... the GPs’ prescribing behaviour is influenced by selected factors. Method The study consists of a register-based study and a questionnaire study. The register-based study is based on data from the Register of Medicinal Product Statistics (prescribed antibiotics), Statistics Denmark (socio-demographic data...

  5. A cross-sectional survey among patients and prescribers on insulin dosing irregularities and impact of mild (self-treated) hypoglycemia episodes in Spanish patients with type 2 diabetes as compared to other European patients.

    Science.gov (United States)

    Ampudia-Blasco, Francisco J; Galán, Manuel; Brod, Meryl

    2014-10-01

    In Spain, data suggest that 13.8% of adults have diabetes. Two important aspects in diabetes management are mild hypoglycemic episodes and poor treatment adherence. This study assesses the impact of missed insulin doses and prevalence of mistimed and reduced insulin doses and mild hypoglycemia in patients with type 2 diabetes treated with basal insulin analogues in Spain, and compares the data collected to pooled data from 8 other European countries (OECs). GAPP2 was an international, online, cross-sectional study of diabetic patients aged ≥40 years treated with long-acting insulin analogues and their healthcare professionals. Patients and healthcare professionals were recruited from online research panels. Data reported in Spain are compared to pooled data from 8 OECs. In Spain, 1-3% of patients reported they had reduced, missed, or mistimed at least one insulin does in the previous month. Significantly more OEC patients reported dosing irregularities (15-23%; all P<0.01). In Spain, 77% of patients were worried and 59% felt guilty for missing a dose of basal insulin, while 24% reported that they were very worried about nocturnal hypoglycemia. Significantly fewer OEC patients reported worrying (47%; P<0.01) and feeling guilty (37%; P<0.01) about missing an insulin dose, or worry about nocturnal hypoglycemia (12%; P<0.01). In Spain, patients with type 2 diabetes report fewer dosing irregularities and hypoglycemic episodes as compared to patients from OECs. However, Spanish patients appear to have a reduced quality of life related to hypoglycemia as well as worry and guilt related to insulin dosing irregularities. Copyright © 2014 SEEN. Published by Elsevier Espana. All rights reserved.

  6. A trial of radiation dose prescription based on dose-cell survival formula

    International Nuclear Information System (INIS)

    Allen, E.P.

    1984-01-01

    Radiation treatment has been prescribed for 379 basal cell carcinomata on the basis of a selected equivalent single dose derived from the standard multi-target dose-cell survival formula using values of m = 2 and Do = 130 rads for orthovoltage x-rays. The results suggest that the approach provides a flexible and acceptable alternative to prescription by total dose or by Nominal Standard Dose. It is submitted that Total Dose is an inadequate expression of radiobiological effects: that the NSD and related systems are valuable measures of the ability of normal tissues to recover from radiation damage: and that a parallel measure of the degree of tumour depopulation has become necessary to allow further progress in alternative fractionation schedules

  7. Early changes in GABA and dlutamine levels and aminotransferase activity in rat brain after total-body γ-irradiation with absolutely lethal doses

    International Nuclear Information System (INIS)

    Rozanov, V.A.; Karpovich, G.A.

    1985-01-01

    The contents of gaama-aminobutyric acid (GABA) and glutamate (GL) as well as GABA-aspartate- and alanine aminotransferase activities were measured in rat cerebellum, cerebral cortex and truncus cerebri 1, 3, 6, 24 and 48 hr following total-body γ-irradiation ( 60 Co) with a dose of 30 Gy. All the indices under study changed in a similar way in the cortex and truncus cerebri while in the cerebellum, GABA level increased and GABA-α-ketoglutarate aminotransfearse activity decreased 60 min after irradiation. The levels of GABA and GL in the cortex and truncus cerebri decreased immediately and increased 24 hr after irradiation. Activity of aminotransferases changed in a phase manner: changes in aspartate- and alanine aminotransferase activity were more pronounced than those of GABA-α-ketoglutarate aminotransferase activity and correlated with the glutamate level changes

  8. Total Ionizing Dose Effects of Si Vertical Diffused MOSFET with SiO2 and Si3N4/SiO2 Gate Dielectrics

    Directory of Open Access Journals (Sweden)

    Jiongjiong Mo

    2017-01-01

    Full Text Available The total ionizing dose irradiation effects are investigated in Si vertical diffused MOSFETs (VDMOSs with different gate dielectrics including single SiO2 layer and double Si3N4/SiO2 layer. Radiation-induced holes trapping is greater for single SiO2 layer than for double Si3N4/SiO2 layer. Dielectric oxidation temperature dependent TID effects are also studied. Holes trapping induced negative threshold voltage shift is smaller for SiO2 at lower oxidation temperature. Gate bias during irradiation leads to different VTH shift for different gate dielectrics. Single SiO2 layer shows the worst negative VTH at VG=0 V, while double Si3N4/SiO2 shows negative VTH shift at VG=-5 V, positive VTH shift at VG=10 V, and negligible VTH shift at VG=0 V.

  9. Local tumor control and cosmetic outcome following breast-conserving surgery and radiation up to a total dose of 56 Gy without boost in breast cancer patients

    International Nuclear Information System (INIS)

    Bayerl, A.

    2001-01-01

    Purpose: To evaluate overall survival, local tumor control and cosmetic outcome after breast-conserving surgery followed by radiotherapy without boost irradiation. Patients and Methods: In a retrospective study 270 breast cancer patients were treated with breast conserving surgery combined with a homogenous radiation of the tumor bearing breast up to a total dose of 56 Gy without local boost irradiation. Mean follow-up was 48 months. Local tumor control, side effects, cosmetic results and contentment with treatment were assessed using physical examinations and interviews based on a standardized questionnaire. Results: Cause-specific survival at 5 years after treatment was 88.3%, actuarial disease-free survival at 5 years was 76.1%. Within 23 to 78 months after treatment 12 patients suffered from ipsilateral breast recurrence. The actuarial freedom from local recurrence (single tumor manifestation) was 96.8% at 5 years after treatment, 89% at 10 years. The occurrence of local failures was not significantly correlated to tumor size, margins, grading, nodal status, age or lymphangiosis. 15.6% of the patients developed distant metastases. In all patients treatment was performed without interruption. Side effects were predominantly of mild degree, no severe side effects were detected. 73% of physicians and 81% of patients scored their cosmetic outcome as excellent or good. 93% of patients would again decide in favor of this procedure. Whereas, use of adjuvant chemotherapy as well as subcutaneous reconstruction of breast tissue did not significantly affect breast cosmesis, analysis demonstrated impaired cosmetic results related to a larger breast size. Conclusion: The data of this study show that tumor control achieved by breast conserving surgery in combination with a radiation technique up to a total dose of 56 Gy which omits boost irradiation is within the range of literature data. Side effects of the therapy were tolerable. The treatment displayed a good

  10. Reducing dose to the lungs through loosing target dose homogeneity requirement for radiotherapy of non small cell lung cancer.

    Science.gov (United States)

    Miao, Junjie; Yan, Hui; Tian, Yuan; Ma, Pan; Liu, Zhiqiang; Li, Minghui; Ren, Wenting; Chen, Jiayun; Zhang, Ye; Dai, Jianrong

    2017-11-01

    It is important to minimize lung dose during intensity-modulated radiation therapy (IMRT) of nonsmall cell lung cancer (NSCLC). In this study, an approach was proposed to reduce lung dose by relaxing the constraint of target dose homogeneity during treatment planning of IMRT. Ten NSCLC patients with lung tumor on the right side were selected. The total dose for planning target volume (PTV) was 60 Gy (2 Gy/fraction). For each patient, two IMRT plans with six beams were created in Pinnacle treatment planning system. The dose homogeneity of target was controlled by constraints on the maximum and uniform doses of target volume. One IMRT plan was made with homogeneous target dose (the resulting target dose was within 95%-107% of the prescribed dose), while another IMRT plan was made with inhomogeneous target dose (the resulting target dose was more than 95% of the prescribed dose). During plan optimization, the dose of cord and heart in two types of IMRT plans were kept nearly the same. The doses of lungs, PTV and organs at risk (OARs) between two types of IMRT plans were compared and analyzed quantitatively. For all patients, the lung dose was decreased in the IMRT plans with inhomogeneous target dose. On average, the mean dose, V5, V20, and V30 of lung were reduced by 1.4 Gy, 4.8%, 3.7%, and 1.7%, respectively, and the dose to normal tissue was also reduced. These reductions in DVH values were all statistically significant (P target dose could protect lungs better and may be considered as a choice for treating NSCLC. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  11. The cumulative cost of additional wakefulness: dose-response effects on neurobehavioral functions and sleep physiology from chronic sleep restriction and total sleep deprivation

    Science.gov (United States)

    Van Dongen, Hans P A.; Maislin, Greg; Mullington, Janet M.; Dinges, David F.

    2003-01-01

    OBJECTIVES: To inform the debate over whether human sleep can be chronically reduced without consequences, we conducted a dose-response chronic sleep restriction experiment in which waking neurobehavioral and sleep physiological functions were monitored and compared to those for total sleep deprivation. DESIGN: The chronic sleep restriction experiment involved randomization to one of three sleep doses (4 h, 6 h, or 8 h time in bed per night), which were maintained for 14 consecutive days. The total sleep deprivation experiment involved 3 nights without sleep (0 h time in bed). Each study also involved 3 baseline (pre-deprivation) days and 3 recovery days. SETTING: Both experiments were conducted under standardized laboratory conditions with continuous behavioral, physiological and medical monitoring. PARTICIPANTS: A total of n = 48 healthy adults (ages 21-38) participated in the experiments. INTERVENTIONS: Noctumal sleep periods were restricted to 8 h, 6 h or 4 h per day for 14 days, or to 0 h for 3 days. All other sleep was prohibited. RESULTS: Chronic restriction of sleep periods to 4 h or 6 h per night over 14 consecutive days resulted in significant cumulative, dose-dependent deficits in cognitive performance on all tasks. Subjective sleepiness ratings showed an acute response to sleep restriction but only small further increases on subsequent days, and did not significantly differentiate the 6 h and 4 h conditions. Polysomnographic variables and delta power in the non-REM sleep EEG-a putative marker of sleep homeostasis--displayed an acute response to sleep restriction with negligible further changes across the 14 restricted nights. Comparison of chronic sleep restriction to total sleep deprivation showed that the latter resulted in disproportionately large waking neurobehavioral and sleep delta power responses relative to how much sleep was lost. A statistical model revealed that, regardless of the mode of sleep deprivation, lapses in behavioral alertness

  12. Dose optimization with first-order total-variation minimization for dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hojin; Li Ruijiang; Lee, Rena; Goldstein, Thomas; Boyd, Stephen; Candes, Emmanuel; Xing Lei [Department of Electrical Engineering, Stanford University, Stanford, California 94305-9505 (United States) and Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Department of Radiation Oncology, Ehwa University, Seoul 158-710 (Korea, Republic of); Department of Electrical Engineering, Stanford University, Stanford, California 94305-9505 (United States); Department of Statistics, Stanford University, Stanford, California 94305-4065 (United States); Department of Radiation Oncology, Stanford University, Stanford, California 94305-5304 (United States)

    2012-07-15

    Purpose: A new treatment scheme coined as dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT) has recently been proposed to bridge the gap between IMRT and VMAT. By increasing the angular sampling of radiation beams while eliminating dispensable segments of the incident fields, DASSIM-RT is capable of providing improved conformity in dose distributions while maintaining high delivery efficiency. The fact that DASSIM-RT utilizes a large number of incident beams represents a major computational challenge for the clinical applications of this powerful treatment scheme. The purpose of this work is to provide a practical solution to the DASSIM-RT inverse planning problem. Methods: The inverse planning problem is formulated as a fluence-map optimization problem with total-variation (TV) minimization. A newly released L1-solver, template for first-order conic solver (TFOCS), was adopted in this work. TFOCS achieves faster convergence with less memory usage as compared with conventional quadratic programming (QP) for the TV form through the effective use of conic forms, dual-variable updates, and optimal first-order approaches. As such, it is tailored to specifically address the computational challenges of large-scale optimization in DASSIM-RT inverse planning. Two clinical cases (a prostate and a head and neck case) are used to evaluate the effectiveness and efficiency of the proposed planning technique. DASSIM-RT plans with 15 and 30 beams are compared with conventional IMRT plans with 7 beams in terms of plan quality and delivery efficiency, which are quantified by conformation number (CN), the total number of segments and modulation index, respectively. For optimization efficiency, the QP-based approach was compared with the proposed algorithm for the DASSIM-RT plans with 15 beams for both cases. Results: Plan quality improves with an increasing number of incident beams, while the total number of segments is maintained to be about the

  13. Respiratory drugs prescribed off-label among children in the outpatient clinics of a hospital in Malaysia.

    Science.gov (United States)

    Mohamad, Nurul Fadilah; Mhd Ali, Adliah; Mohamed Shah, Noraida

    2015-02-01

    Prescribing medicines in an unlicensed and off-label manner for children is a widespread practice around the world. To determine the extent and predictors of off-label respiratory drug prescriptions for children in the outpatient clinics of a hospital in Malaysia. Outpatient clinics at the Universiti Kebangsaan Malaysia Medical Centre, a tertiary teaching hospital in Malaysia. The pharmacy-based computer system and medical records of the patients were utilized to collect data from 220 pediatric patients who were prescribed at least one respiratory drug from July 2011 to December 2011. Characteristics of the off-label respiratory drug prescriptions were measured. A total of 134 children (60.9 %) received at least one respiratory drug prescribed in an off-label manner. The most common reasons for the off-label prescribing of drugs were off-label use by indication (31.5 %), followed by higher than the recommended dose (24.9 %) and lower than the recommended frequency (17.1 %). Diphenhydramine was the most common respiratory drug prescribed off-label. The number of medications prescribed was the only significant predictor of off-label prescription of respiratory drugs. Pediatric patients receiving 4-6 medications were 7.8 times more likely to receive at least one off-label respiratory drug compared to pediatric patients that received 1-3 medications (OR 7.8, 95 % CI 1.74-37.44). There was substantial prescribing of respiratory drugs for children in an off-label manner at the outpatient clinics at the Universiti Kebangsaan Malaysia Medical Centre. This highlights the need for more research to be carried out on respiratory drugs in the pediatric population.

  14. Efficacy and safety of total dose infusion of low molecular weight iron dextran in the treatment of iron deficiency anemia during pregnancy

    International Nuclear Information System (INIS)

    Ayub, R.; Tariq, N.; Iqbal, M.; Jafery, T.

    2008-01-01

    To determine the efficacy and safety of Total Dose Infusion (TDI) of low molecular weight iron dextran for the treatment of iron deficiency anemia compared to oral iron replacement during pregnancy through improvement in hemoglobin (Hb) after intervention. Non-randomized control trial. A group of 100 pregnant women with gestational age greater than 12 weeks with confirmed diagnosis of iron deficiency anemia attending the antenatal clinics were enrolled in this study. Total dose iron infusion of low molecular iron dextran was given to these patients after calculating iron deficit, in a monitored in-patient setting. Control comprised of a second group of 50 pregnant females matched for age, parity and baseline hemoglobin, tolerant to oral iron supplementation (ferrous sulphate 200 mg three times a day) attending the antenatal clinics during the same period. Post-treatment hemoglobin levels of study group as well as the oral control group were determined between 3 to 4 weeks. In the intervention group, mean pre-infusion hemoglobin level was 8.57 +- 0.9 gm/dl (range 5-10.5 gm/dl) and mean post-infusion Hb was 11.0 +- 1.1 (range 8.4-14.3 gm/dl). In control group, mean pre-oral intake Hb level was 9.5 +- 0.9 gm/dl (range 7-10.5 gm/dl) and mean post-oral intake Hb was 10.2 +- 1.2 gm/dl (range 6.4-12.8 gm/dl). Mean increase of Hb in intervention group was 2.43 gm/dl (95% CI 2.4 - 3.8) and for controls it was 0.7 gm/dl (95% CI 0.6-2.3). Flushing and palpitations were observed in 4% of interventional group patients and none in the control group. No significant adverse reactions were observed in either group. We conclude that the total parenteral iron replacement with low molecular weight iron dextran is an effective and safe method for the treatment of iron deficiency anemia in a selected group of pregnant women. (author)

  15. Prescribing psychotropic drugs to adults with an intellectual disability

    Science.gov (United States)

    Trollor, Julian N; Salomon, Carmela; Franklin, Catherine

    2016-01-01

    SUMMARY Mental illness is common in people with intellectual disability. They may also have physical health problems which can affect their mental state. Difficulties in communication can contribute to mental health problems being overlooked. These may present with changes in behaviour. Psychological management is usually preferable to prescribing psychotropic drugs. Behavioural approaches are the most appropriate way to manage challenging behaviour. If a drug is considered, prescribers should complete a thorough diagnostic assessment, exclude physical and environmental contributions to symptoms, and consider medical comorbidities before prescribing. Where possible avoid psychotropics with the highest cardiometabolic burden. Prescribe the minimum effective dose and treatment length, and regularly monitor drug efficacy and adverse effects. There is insufficient evidence to support the use of psychotropics for challenging behaviour. They should be avoided unless the behaviour is severe and non-responsive to other treatments. PMID:27756975

  16. The Supply of Prescription Opioids: Contributions of Episodic-Care Prescribers and High-Quantity Prescribers.

    Science.gov (United States)

    Schneberk, Todd; Raffetto, Brian; Kim, David; Schriger, David L

    2018-06-01

    We determine episodic and high-quantity prescribers' contribution to opioid prescriptions and total morphine milligram equivalents in California, especially among individuals prescribed large amounts of opioids. This was a cross-sectional descriptive analysis of opioid prescribing patterns during an 8-year period using the de-identified Controlled Substance Utilization Review and Evaluation System (CURES) database, the California subsection of the prescription drug monitoring program. We took a 10% random sample of all patients and stratified them by the amount of prescription opioids obtained during their maximal 90-day period. We identified "episodic prescribers" as those whose prescribing pattern included short-acting opioids on greater than 95% of all prescriptions, fewer than or equal to 31 pills on 95% of all prescriptions, only 1 prescription in the database for greater than 90% of all patients to whom they gave opioids, fewer than 6 prescriptions in the database to greater than 99% of patients given opioids, and fewer than 540 prescriptions per year. We identified top 5% prescribers by their morphine milligram equivalents per day in the database. We examined the relationship between patient opioid prescriptions and provider type, with the primary analysis performed on the patient cohort who received only short-acting opioids in an attempt to avoid guideline-concordant palliative, oncologic, and addiction care, and a secondary analysis performed on all patients. Among patients with short-acting opioid only, episodic prescribers (14.6% of 173,000 prescribers) wrote at least one prescription to 25% of 2.7 million individuals but were responsible for less than 9% of the 10.5 million opioid prescriptions and less than 3% of the 3.9 billion morphine milligram equivalents in our sample. Among individuals with high morphine milligram equivalents use, episodic prescribers were responsible for 2.8% of prescriptions and 0.6% of total morphine milligram equivalents

  17. Prescribed burning: a topical issue

    Directory of Open Access Journals (Sweden)

    Bovio G

    2013-11-01

    Full Text Available Prescribed burning is a promising technique for the prevention of forest fires in Italy. The research deepened several ecological and operative aspects. However, legal issues need to be thoroughly investigated.

  18. Safe prescribing: a titanic challenge.

    Science.gov (United States)

    Routledge, Philip A

    2012-10-01

    The challenge to achieve safe prescribing merits the adjective 'titanic'. The organisational and human errors leading to poor prescribing (e.g. underprescribing, overprescribing, misprescribing or medication errors) have parallels in the organisational and human errors that led to the loss of the Titanic 100 years ago this year. Prescribing can be adversely affected by communication failures, critical conditions, complacency, corner cutting, callowness and a lack of courage of conviction, all of which were also factors leading to the Titanic tragedy. These issues need to be addressed by a commitment to excellence, the final component of the 'Seven C's'. Optimal prescribing is dependent upon close communication and collaborative working between highly trained health professionals, whose role is to ensure maximum clinical effectiveness, whilst also protecting their patients from avoidable harm. Since humans are prone to error, and the environments in which they work are imperfect, it is not surprising that medication errors are common, occurring more often during the prescribing stage than during dispensing or administration. A commitment to excellence in prescribing includes a continued focus on lifelong learning (including interprofessional learning) in pharmacology and therapeutics. This should be accompanied by improvements in the clinical working environment of prescribers, and the encouragement of a strong safety culture (including reporting of adverse incidents as well as suspected adverse drug reactions whenever appropriate). Finally, members of the clinical team must be prepared to challenge each other, when necessary, to ensure that prescribing combines the highest likelihood of benefit with the lowest potential for harm. © 2012 The Author. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  19. Safe prescribing: a titanic challenge

    Science.gov (United States)

    Routledge, Philip A

    2012-01-01

    The challenge to achieve safe prescribing merits the adjective ‘titanic’. The organisational and human errors leading to poor prescribing (e.g. underprescribing, overprescribing, misprescribing or medication errors) have parallels in the organisational and human errors that led to the loss of the Titanic 100 years ago this year. Prescribing can be adversely affected by communication failures, critical conditions, complacency, corner cutting, callowness and a lack of courage of conviction, all of which were also factors leading to the Titanic tragedy. These issues need to be addressed by a commitment to excellence, the final component of the ‘Seven C's’. Optimal prescribing is dependent upon close communication and collaborative working between highly trained health professionals, whose role is to ensure maximum clinical effectiveness, whilst also protecting their patients from avoidable harm. Since humans are prone to error, and the environments in which they work are imperfect, it is not surprising that medication errors are common, occurring more often during the prescribing stage than during dispensing or administration. A commitment to excellence in prescribing includes a continued focus on lifelong learning (including interprofessional learning) in pharmacology and therapeutics. This should be accompanied by improvements in the clinical working environment of prescribers, and the encouragement of a strong safety culture (including reporting of adverse incidents as well as suspected adverse drug reactions whenever appropriate). Finally, members of the clinical team must be prepared to challenge each other, when necessary, to ensure that prescribing combines the highest likelihood of benefit with the lowest potential for harm. PMID:22738396

  20. Zolpidem prescribing practices before and after Food and Drug Administration required product labeling changes.

    Science.gov (United States)

    Norman, Jessica L; Fixen, Danielle R; Saseen, Joseph J; Saba, Laura M; Linnebur, Sunny A

    2017-01-01

    Women have higher morning serum zolpidem concentrations than men after taking an evening dose, potentially leading to increased risk of harm. On 19 April 2013, the United States Food and Drug Administration required labeling changes for zolpidem, recommending an initial dose of no greater than 5 mg (immediate release) or 6.25 mg (controlled release) per night in women. The primary objective of this study was to compare prescribing practices before and after the 2013 zolpidem labeling change. A secondary objective was to evaluate serious adverse events potentially related to zolpidem. Electronic medical records of adults receiving care through the University of Colorado Health system were accessed for study inclusion if patients were provided a first-time prescription for zolpidem either prior to or after the Food and Drug Administration labeling change. Patients were randomly chosen from eight strata based on age, gender, and date of zolpidem initiation (before/after the labeling change). Demographic and zolpidem prescribing data were collected. Low-dose zolpidem was considered 5 mg (immediate release) or 6.25 mg (controlled release) daily or less. Documentation of potentially related serious adverse events within the patients' records was also evaluated. A total of 400 patients were included in the study. The overall percentage of patients prescribed low-dose zolpidem increased from 44% to 58% after the labeling change (p = 0.0020). In a pre-specified subgroup analysis, the percentage of patients prescribed low-dose zolpidem increased in all groups, including young men (38%-50%, p = 0.23), elderly men (34%-40%, p = 0.53), and elderly women (60%-74%, p = 0.14), but the change was only significant in young women (42%-70%, p = 0.0045). After Food and Drug Administration-mandated labeling changes for zolpidem in 2013, the percentage of overall patients in our health system, and specifically young women, with initial prescriptions for low-dose

  1. Zolpidem prescribing practices before and after Food and Drug Administration required product labeling changes

    Directory of Open Access Journals (Sweden)

    Jessica L Norman

    2017-05-01

    Full Text Available Background: Women have higher morning serum zolpidem concentrations than men after taking an evening dose, potentially leading to increased risk of harm. On 19 April 2013, the United States Food and Drug Administration required labeling changes for zolpidem, recommending an initial dose of no greater than 5 mg (immediate release or 6.25 mg (controlled release per night in women. Objectives: The primary objective of this study was to compare prescribing practices before and after the 2013 zolpidem labeling change. A secondary objective was to evaluate serious adverse events potentially related to zolpidem. Methods: Electronic medical records of adults receiving care through the University of Colorado Health system were accessed for study inclusion if patients were provided a first-time prescription for zolpidem either prior to or after the Food and Drug Administration labeling change. Patients were randomly chosen from eight strata based on age, gender, and date of zolpidem initiation (before/after the labeling change. Demographic and zolpidem prescribing data were collected. Low-dose zolpidem was considered 5 mg (immediate release or 6.25 mg (controlled release daily or less. Documentation of potentially related serious adverse events within the patients’ records was also evaluated. Results: A total of 400 patients were included in the study. The overall percentage of patients prescribed low-dose zolpidem increased from 44% to 58% after the labeling change (p = 0.0020. In a pre-specified subgroup analysis, the percentage of patients prescribed low-dose zolpidem increased in all groups, including young men (38%–50%, p = 0.23, elderly men (34%–40%, p = 0.53, and elderly women (60%–74%, p = 0.14, but the change was only significant in young women (42%–70%, p = 0.0045. Conclusion: After Food and Drug Administration–mandated labeling changes for zolpidem in 2013, the percentage of overall patients in our health

  2. US outpatient antibiotic prescribing variation according to geography, patient population, and provider specialty in 2011.

    Science.gov (United States)

    Hicks, Lauri A; Bartoces, Monina G; Roberts, Rebecca M; Suda, Katie J; Hunkler, Robert J; Taylor, Thomas H; Schrag, Stephanie J

    2015-05-01

    Appropriate antibiotic prescribing is an essential strategy to reduce the spread of antibiotic resistance. US prescribing practices have not been thoroughly characterized. We analyzed outpatient antibiotic prescribing data to identify where appropriate antibiotic prescribing interventions could have the most impact. Oral antibiotic prescriptions dispensed during 2011 were extracted from the IMS Health Xponent database. The number of prescriptions and census denominators were used to calculate prescribing rates. Prescription totals were calculated for each provider specialty. Regression modeling was used to examine the association between socioeconomic and population health factors and prescribing rates. Healthcare providers prescribed 262.5 million courses of antibiotics in 2011(842 prescriptions per 1000 persons). Penicillins and macrolides were the most common antibiotic categories prescribed. The most commonly prescribed individual antibiotic agent was azithromycin. Family practitioners prescribed the most antibiotic courses (24%). The prescribing rate was higher in the South census region (931 prescriptions per 1000 persons) than in the West (647 prescriptions per 1000 persons; P 1.0). Efforts to characterize antibiotic prescribing practices should focus on the South census region and family practitioners. Further understanding of the factors leading to high prescribing among key target populations will inform appropriate prescribing interventions. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  3. Ionizing radiation and autoimmunity: Induction of autoimmune disease in mice by high dose fractionated total lymphoid irradiation and its prevention by inoculating normal T cells

    International Nuclear Information System (INIS)

    Sakaguchi, N.; Sakaguchi, S.; Miyai, K.

    1992-01-01

    Ionizing radiation can functionally alter the immune system and break self-tolerance. High dose (42.5 Gy), fractionated (2.5 Gy 17 times) total lymphoid irradiation (TLI) on mice caused various organ-specific autoimmune diseases, such as gastritis, thyroiditis, and orchitis, depending on the radiation dosages, the extent of lymphoid irradiation, and the genetic background of the mouse strains. Radiation-induced tissue damage is not the primary cause of the autoimmune disease because irradiation of the target organs alone failed to elicit the autoimmunity and shielding of the organs from irradiation was unable to prevent it. In contrast, irradiation of both the thymus and the peripheral lymphoid organs/tissues was required for efficient induction of autoimmune disease by TLI. TLI eliminated the majority of mature thymocytes and the peripheral T cells for 1 mo, and inoculation of spleen cell, thymocyte, or bone marrow cell suspensions (prepared from syngeneic nonirradiated mice) within 2 wk after TLI effectively prevented the autoimmune development. Depletion of T cells from the inocula abrogated the preventive activity. CD4 + T cells mediated the autoimmune prevention but CD8 + T cells did not. CD4 + T cells also appeared to mediate the TLI-induced autoimmune disease because CD4 + T cells from disease-bearing TLI mice adoptively transferred the autoimmune disease to syngeneic naive mice. Taken together, these results indicate that high dose, fractionated ionizing radiation on the lymphoid organs/tissues can cause autoimmune disease by affecting the T cell immune system, rather than the target self-Ags, presumably by altering T cell-dependent control of self-reactive T cells. 62 refs., 9 figs., 2 tabs

  4. Introduction to prescribed fires in Southern ecosystems

    Science.gov (United States)

    Thomas A. Waldrop; Scott L. Goodrick

    2012-01-01

    This publication is a guide for resource managers on planning and executing prescribed burns in Southern forests and grasslands. It includes explanations of reasons for prescribed burning, environmental effects, weather, and techniques as well as general information on prescribed burning.

  5. Cardiovascular effects, induction and recovery characteristics and alfaxalone dose assessment in alfaxalone versus alfaxalone-fentanyl total intravenous anaesthesia in dogs.

    Science.gov (United States)

    Dehuisser, Virginie; Bosmans, Tim; Kitshoff, Adriaan; Duchateau, Luc; de Rooster, Hilde; Polis, Ingeborgh

    2017-11-01

    To compare cardiovascular effects and anaesthetic quality of alfaxalone alone or in combination with a fentanyl constant rate infusion (CRI) when used for total intravenous anaesthesia (TIVA) in dogs. Prospective, blinded, randomized, experimental study. A group of 12 intact female dogs. Following intramuscular dexmedetomidine (10 μg kg -1 ) and methadone (0.1 mg kg -1 ) administration, anaesthesia was induced intravenously with alfaxalone (2 mg kg -1 ) (group AP) or alfaxalone (2 mg kg -1 ) preceded by fentanyl (2 μg kg -1 ) (group AF). Anaesthetic maintenance was obtained with an alfaxalone variable rate infusion (VRI) started at 0.15 mg kg -1 minute -1 (group AP) or an alfaxalone VRI (same starting rate) combined with a CRI of fentanyl (10 μg kg -1 hour -1 ) (group AF). The alfaxalone VRI was adjusted every 5 minutes, based on clinical assessment. Cardiovascular parameters (recorded every 5 minutes) and recovery characteristics (using a numerical rating scale) were compared between groups. A mixed model statistical approach was used to compare the mean VRI alfaxalone dose and cardiovascular parameters between groups; recovery scores were analysed using the Wilcoxon rank-sum test (α = 0.05). The mean CRI alfaxalone dose for anaesthetic maintenance differed significantly between treatments [0.16 ± 0.01 mg kg -1 minute -1 (group AP) versus 0.13 ± 0.01 mg kg -1 minute -1 (group AF)]. Overall heart rate, systolic, mean and diastolic arterial pressures were lower in group AF than in group AP (p < 0.0001, p = 0.0058, p < 0.0001 and p < 0.0001, respectively. Recovery quality scores did not differ significantly and were poor in both groups. In combination with a fentanyl CRI, an alfaxalone TIVA provides a cardiovascular stable anaesthesia in dogs. The addition of fentanyl results in a significant dose reduction. The quality of anaesthetic recovery remains poor. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia

  6. Analysis of Out Door Patients' Prescriptions According to World Health Organization (WHO) Prescribing Indicators Among Private Hospitals in Western India.

    Science.gov (United States)

    Shelat, Prakash R; Kumbar, Shivaprasad Kalakappa

    2015-03-01

    Prescription is document through which doctor, patient and pharmacist are communicated. Many a times if these documents are not properly written or misinterpreted it can affect management of patients. WHO established prescribing indicators to analyse prescription and promoted rational use of drugs and better management of patients. To study the prescription pattern according to WHO prescribing indicators among private hospitals. The observational, prospective study carried out at different private hospitals at metro city in Western India to study the prescription pattern among private hospital. Study was conducted at different private hospitals of metro city. A total of 250 prescriptions of outdoor patients from various departments of private hospitals were collected for a period of three months (August to October) 2012 and evaluated. The study was analysed using Z-test. Patient details like age and gender was not written in all (100%) prescriptions. It was noticed that dose, direction of drug and duration of treatment was not completely written in 90%, 74% and 80% of prescriptions respectively. Abbreviations were used in all (100%) prescriptions. Doctor's medical registration number was mentioned in 0% prescriptions. Total 869 drugs were prescribed in 250 prescriptions. Average number of drug prescribed was 3.38±1.79 (Mean±SD). It was reported that Group II (3 to 4 encoutner) was significantly higher as compared to Group I (less than or equal to 2 encoutner) and Group III( more than four encounter). It was significantly (pprivate hospitals and antibiotics was commonly prescribed in private sector. Therefore, strict policy to good prescribing practice and strict antibiotic policy in outdoor patients are required to promote rational use of drugs.

  7. Total body irradiation (TBI) in pediatric patients. A single-center experience after 30 years of low-dose rate irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmeier, Claudia; Thoennessen, Daniel; Negretti, Laura; Streller, Tino; Luetolf, Urs Martin [University Hospital Zurich (Switzerland). Dept. of Radiation-Oncology; Bourquin, Jean-Pierre [University Children' s Hospital Zurich (Switzerland). Dept. of Hemato-Oncology; Oertel, Susanne [University Hospital Zurich (Switzerland). Dept. of Radiation-Oncology; Heidelberg Univ. (Germany). Dept. of Radiation Oncology

    2010-11-15

    To retrospectively analyze patient characteristics, treatment, and treatment outcome of pediatric patients with hematologic diseases treated with total body irradiation (TBI) between 1978 and 2006. 32 pediatric patients were referred to the Department of Radiation-Oncology at the University of Zurich for TBI. Records of regular follow-up of 28 patients were available for review. Patient characteristics as well as treatment outcome regarding local control and overall survival were assessed. A total of 18 patients suffered from acute lymphoblastic leukemia (ALL), 5 from acute and 2 from chronic myelogenous leukemia, 1 from non-Hodgkin lymphoma, and 2 from anaplastic anemia. The cohort consisted of 15 patients referred after first remission and 13 patients with relapsed leukemia. Mean follow-up was 34 months (2-196 months) with 15 patients alive at the time of last follow-up. Eight patients died of recurrent disease, 1 of graft vs. host reaction, 2 of sepsis, and 2 patients died of a secondary malignancy. The 5-year overall survival rate (OS) was 60%. Overall survival was significantly inferior in patients treated after relapse compared to those treated for newly diagnosed leukemia (24% versus 74%; p=0.004). At the time of last follow-up, 11 patients survived for more than 36 months following TBI. Late effects (RTOG {>=}3) were pneumonitis in 1 patient, chronic bronchitis in 1 patient, cardiomyopathy in 2 patients, severe cataractogenesis in 1 patient (48 months after TBI with 10 Gy in a single dose) and secondary malignancies in 2 patients (36 and 190 months after TBI). Growth disturbances were observed in all patients treated prepubertally. In 2 patients with identical twins treated at ages 2 and 7, a loss of 8% in final height of the treated twin was observed. As severe late sequelae after TBI, we observed 2 secondary malignancies in 11 patients who survived in excess of 36 months. However, long-term morbidity is moderate following treatment with the fractionated

  8. The use of paracetamol (acetaminophen) among a community sample of people with chronic non-cancer pain prescribed opioids.

    Science.gov (United States)

    Hoban, B; Larance, B; Gisev, N; Nielsen, S; Cohen, M; Bruno, R; Shand, F; Lintzeris, N; Hall, W; Farrell, M; Degenhardt, L

    2015-11-01

    The regular use of simple analgesics in addition to opioids such as paracetamol (or acetaminophen) is recommended for persistent pain to enhance analgesia. Few studies have examined the frequency and doses of paracetamol among people with chronic non-cancer pain including use above the recommended maximum daily dose. To assess (i) the prevalence of paracetamol use among people with chronic non-cancer pain prescribed opioids, (ii) assess the prevalence of paracetamol use above the recommended maximum daily dose and (iii) assess correlates of people who used paracetamol above the recommended maximum daily dose including: age, gender, income, education, pain severity and interference, use of paracetamol/opioid combination analgesics, total opioid dose, depression, anxiety, pain self-efficacy or comorbid substance use, among people prescribed opioids for chronic non-cancer pain. This study draws on baseline data collected for the Pain and Opioids IN Treatment (POINT) study and utilises data from 962 interviews and medication diaries. The POINT study is national prospective cohort of people with chronic non-cancer pain prescribed opioids. Participants were recruited from randomly selected pharmacies across Australia. Sixty-three per cent of the participants had used paracetamol in the past week (95% CI = 59.7-65.8). Among the paracetamol users 22% (95% CI = 19.3-24.6) had used paracetamol/opioid combination analgesics and 4.8% (95% CI = 3.6-6.3) had used paracetamol above the recommended maximum daily dose (i.e. > 4000 mg/day). Following binomial logistic regression (χ(2) = 25.98, df = 10, p = 0.004), people who had taken above the recommended maximum daily dose were less likely to have low income (AOR = 0.52, 95% CI = 0.27-0.99), more likely to use paracetamol/opioid combination analgesics (AOR = 2.01, 95% CI = 1.02-3.98) and more likely to take a higher opioid dose (AOR = 1.00, 95% CI = 1.00-1.01). The majority of people with chronic non-cancer pain prescribed

  9. Inappropriate prescribing in the elderly.

    LENUS (Irish Health Repository)

    Gallagher, P

    2012-02-03

    BACKGROUND AND OBJECTIVE: Drug therapy is necessary to treat acute illness, maintain current health and prevent further decline. However, optimizing drug therapy for older patients is challenging and sometimes, drug therapy can do more harm than good. Drug utilization review tools can highlight instances of potentially inappropriate prescribing to those involved in elderly pharmacotherapy, i.e. doctors, nurses and pharmacists. We aim to provide a review of the literature on potentially inappropriate prescribing in the elderly and also to review the explicit criteria that have been designed to detect potentially inappropriate prescribing in the elderly. METHODS: We performed an electronic search of the PUBMED database for articles published between 1991 and 2006 and a manual search through major journals for articles referenced in those located through PUBMED. Search terms were elderly, inappropriate prescribing, prescriptions, prevalence, Beers criteria, health outcomes and Europe. RESULTS AND DISCUSSION: Prescription of potentially inappropriate medications to older people is highly prevalent in the United States and Europe, ranging from 12% in community-dwelling elderly to 40% in nursing home residents. Inappropriate prescribing is associated with adverse drug events. Limited data exists on health outcomes from use of inappropriate medications. There are no prospective randomized controlled studies that test the tangible clinical benefit to patients of using drug utilization review tools. Existing drug utilization review tools have been designed on the basis of North American and Canadian drug formularies and may not be appropriate for use in European countries because of the differences in national drug formularies and prescribing attitudes. CONCLUSION: Given the high prevalence of inappropriate prescribing despite the widespread use of drug-utilization review tools, prospective randomized controlled trials are necessary to identify useful interventions. Drug

  10. Prevalence and Correlates of “High Dose” Antipsychotic Prescribing ...

    African Journals Online (AJOL)

    of 1000 mg/day is considered as high dose prescribing. Furthermore ... genetic variations.[16] ... Annals of Medical and Health Sciences Research | Jan-Mar 2013 | Vol 3 | Issue 1 |. 63 ... the unreliability of the CPZeq criteria in the view of an increasing use of ... We obtained ethical clearance from the Ethics and Research.

  11. A 5-year retrospective audit of prescribing by a critical care outreach team.

    Science.gov (United States)

    Wilson, Mark

    2018-05-01

    UK prescribing legislation changes made in 2006 and 2012 enabled appropriately qualified nurses to prescribe any licensed medication, and all controlled drugs in schedule 2-5 of the Misuse of Drugs Regulations 2001, for any medical condition within their clinical competence. Critical Care Outreach nurses who are independent nurse prescribers are ideally placed to ensure that acutely ill patients receive treatment without delay. The perceived challenge was how Critical Care Outreach nurses would be able to safely prescribe for a diverse patient group. This study informs this developing area of nurse prescribing in critical care practice. The aims of the audit were to: identify which medications were prescribed; develop a critical care outreach formulary; identify the frequency, timing and number of prescribing decisions being made; identify if prescribing practice changed over the years and provide information for our continuing professional development. This article reports on data collected from a 5-year retrospective audit; of prescribing activity undertaken by nine independent nurse prescribers working in a 24/7 Critical Care Outreach team of a 600-bedded district general hospital in the UK. In total, 8216 medication items were prescribed, with an average of 2·6 prescribed per shift. The most commonly prescribed items were intravenous fluids and analgesia, which were mostly prescribed at night and weekends. The audit has shown that Critical Care Outreach nurse prescribing is feasible in a whole hospital patient population. The majority of prescribing occurred after 16:00 and at night. Further research would be beneficial, particularly looking at patient outcomes following reviews from prescribing critical care outreach nurses. The audit is one of the only long-term studies that describes prescribing practice in Critical Care Outreach teams in the UK. © 2017 British Association of Critical Care Nurses.

  12. Treatment of aggressive multiple myeloma by high-dose chemotherapy and total body irradiation followed by blood stem cells autologous graft

    International Nuclear Information System (INIS)

    Fermand, J.P.; Levy, Y.; Gerota, J.; Benbunan, M.; Cosset, J.M.; Castaigne, S.; Seligmann, M.; Brouet, J.C.

    1989-01-01

    Eight patients with stage III aggressive multiple myeloma, refractory to current chemotherapy in six cases, were treated by high-dose chemotherapy (nitrosourea, etoposide, and melphalan) (HDC) and total body irradiation (TBI), followed by autografting with blood stem cells. These cells were previously collected by leukapheresis performed during hematologic recovery following cytotoxic drug-induced bone marrow aplasia. Seven patients were alive 9 to 17 months after HDC-TBI and graft. One died at day 40 from cerebral bleeding. All living patients achieved a 90% or greater reduction in tumor mass. In two cases, a complete remission (CR) has persisted at a follow-up of 15 and 16 months. Three patients have been well and off therapy with stable minimal residual disease (RD) since 10, 11, and 17 months, respectively. A patient in apparent CR and another with RD have relapsed 9 to 12 months posttreatment. Autologous blood-derived hematopoietic stem cells induced successful and sustained engraftment in all living patients. These results, although still preliminary, indicate that HDC and TBI, followed by blood stem cells autograft, which has both practical and theoretical interest over allogeneic or autologous bone marrow transplantation, deserve consideration in selected patients with multiple myeloma

  13. An In Vivo Study of Low-Dose Intra-Articular Tranexamic Acid Application with Prolonged Clamping Drain Method in Total Knee Replacement: Clinical Efficacy and Safety

    Directory of Open Access Journals (Sweden)

    Paphon Sa-ngasoongsong

    2015-01-01

    Full Text Available Background. Recently, combined intra-articular tranexamic acid (IA-TXA injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR. However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. Materials and Methods. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours. Blood and drainage fluid were collected to measure tranexamic acid (TXA level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. Results. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p<0.05. Serum TXA level at time of clamp release was significantly different among groups with the highest level at 2 hour (p<0.0001. There was no significant difference of TXA level in drainage fluid, postoperative blood loss, blood transfusion, and postoperative complications (p<0.05.  Conclusions. Low-dose IA-TXA application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time.

  14. Validity of the Prescriber Information in the Danish National Prescription Registry

    DEFF Research Database (Denmark)

    Rasmussen, Lotte; Valentin, Julie; Gesser, Katarina Margareta

    2016-01-01

    The aim of this study was to measure the validity of the prescriber information recorded in the Danish National Prescription Registry (DNPR). The prescriber information recorded in the pharmacies' electronic dispensing system was considered to represent the prescriber information recorded...... in the DNPR. Further, the problem of validity of the prescriber information pertains only to non-electronic prescriptions, as these are manually entered into the dispensing system. The recorded prescriber information was thus validated against information from a total of 2,000 non-electronic prescriptions...... at five Danish community pharmacies. The validity of the recorded prescriber information was measured at the level of the individual prescriber and the prescriber type, respectively. The proportion of non-electronic prescriptions with incorrect registrations was 22.4% (95% Confidence Interval (CI): 20...

  15. A study of antibiotic prescribing

    DEFF Research Database (Denmark)

    Jaruseviciene, L.; Radzeviciene-Jurgute, R.; Jurgutis, A.

    2012-01-01

    Background. Globally, general practitioners (GPs) write more than 90% of all antibiotic prescriptions. This study examines the experiences of Lithuanian and Russian GPs in antibiotic prescription for upper respiratory tract infections, including their perceptions of when it is not indicated...... clinically or pharmacologically. Methods. 22 Lithuanian and 29 Russian GPs participated in five focus group discussions. Thematic analysis was used to analyse the data. Results. We identified four main thematic categories: patients' faith in antibiotics as medication for upper respiratory tract infections......; patient potential to influence a GP's decision to prescribe antibiotics for upper respiratory tract infections; impediments perceived by GPs in advocating clinically grounded antibiotic prescribing with their patients, and strategies applied in physician-patient negotiation about antibiotic prescribing...

  16. ELECTORAL PRESCRIBERS. WHO ARE THEY?

    Directory of Open Access Journals (Sweden)

    Constantin SASU

    2016-12-01

    Full Text Available The decision to vote and choosing among the candidates is an extremely important one with repercussions on everyday life by determining, in global mode, its quality for the whole society. Therefore the whole process by which the voter decides becomes a central concern. Prescribers, supposed to have a big influence on the electoral market, are a component of the microenvironment political organizations. These are people who occupy important positions that can influence the behavior of others. In the political environment, prescribers are known under the name of "opinion formers", "opinion leaders", "mediators" (Beciu, 2009 or "influencers" (Keller and Berry, 2003 Weimann, 1994. This paper aims to review the central opinions on what is the influence prescribers, opinion makers on voting behavior, voting and decisions on whether and how they act?

  17. To prescribe codeine or not to prescribe codeine?

    Science.gov (United States)

    Fleming, Marc L; Wanat, Matthew A

    2014-09-01

    A recently published study in Pediatrics by Kaiser et al. (2014; Epub April 21, DOI: 10.1542/peds.2013-3171) reported that on average, over the past decade, children aged 3 to 17 were prescribed approximately 700,000 prescriptions for codeine-containing products each year in association with emergency department (ED) visits. Although, guidelines from the American Academy of Pediatrics issued warnings in 1997 and reaffirmed their concerns regarding the safety and effectiveness of codeine in 2006, it is still often prescribed for pain and cough associated with upper respiratory infection. With the impending rescheduling of hydrocodone combination products to Schedule II, physicians and mid-level prescribers may be compelled to prescribe codeine-containing products (e.g., with acetaminophen) due to reduced administrative burden and limits on Schedule II prescriptive authority for nurse practitioners and physician assistants in some states. This commentary expounds on the safety and effectiveness concerns of codeine, with a primary focus on patients in the ED setting.

  18. Psychologists' right to prescribe – should prescribing privileges be ...

    African Journals Online (AJOL)

    Current changes in legislation regarding prescription rights increase the possibility of non-medical practitioners being authorised to presctibe medication. There has been ongoing debate about granting psychologists in South Africa a limited right to prescribe (RTP) psychotropic medication. The main reasons advanced for ...

  19. Medication prescribing errors in a public teaching hospital in India: A prospective study.

    Directory of Open Access Journals (Sweden)

    Pote S

    2007-03-01

    Full Text Available Background: To prevent medication errors in prescribing, one needs to know their types and relative occurrence. Such errors are a great cause of concern as they have the potential to cause patient harm. The aim of this study was to determine the nature and types of medication prescribing errors in an Indian setting.Methods: The medication errors were analyzed in a prospective observational study conducted in 3 medical wards of a public teaching hospital in India. The medication errors were analyzed by means of Micromedex Drug-Reax database.Results: Out of 312 patients, only 304 were included in the study. Of the 304 cases, 103 (34% cases had at least one error. The total number of errors found was 157. The drug-drug interactions were the most frequently (68.2% occurring type of error, which was followed by incorrect dosing interval (12% and dosing errors (9.5%. The medication classes involved most were antimicrobial agents (29.4%, cardiovascular agents (15.4%, GI agents (8.6% and CNS agents (8.2%. The moderate errors contributed maximum (61.8% to the total errors when compared to the major (25.5% and minor (12.7% errors. The results showed that the number of errors increases with age and number of medicines prescribed.Conclusion: The results point to the establishment of medication error reporting at each hospital and to share the data with other hospitals. The role of clinical pharmacist in this situation appears to be a strong intervention; and the clinical pharmacist, initially, could confine to identification of the medication errors.

  20. Prescribed burning for understory restoration

    Science.gov (United States)

    Kenneth W. Outcalt

    2006-01-01

    Because the longleaf ecosystem evolved with and is adapted to frequent fire, every 2 to 8 years, prescribed burning is often useful for restoring understory communities to a diverse ground layer of grasses, herbs, and small shrubs. This restoration provides habitat for a number of plant and animal species that are restricted to or found mostly in longleaf pine...

  1. Automation bias in electronic prescribing.

    Science.gov (United States)

    Lyell, David; Magrabi, Farah; Raban, Magdalena Z; Pont, L G; Baysari, Melissa T; Day, Richard O; Coiera, Enrico

    2017-03-16

    Clinical decision support (CDS) in e-prescribing can improve safety by alerting potential errors, but introduces new sources of risk. Automation bias (AB) occurs when users over-rely on CDS, reducing vigilance in information seeking and processing. Evidence of AB has been found in other clinical tasks, but has not yet been tested with e-prescribing. This study tests for the presence of AB in e-prescribing and the impact of task complexity and interruptions on AB. One hundred and twenty students in the final two years of a medical degree prescribed medicines for nine clinical scenarios using a simulated e-prescribing system. Quality of CDS (correct, incorrect and no CDS) and task complexity (low, low + interruption and high) were varied between conditions. Omission errors (failure to detect prescribing errors) and commission errors (acceptance of false positive alerts) were measured. Compared to scenarios with no CDS, correct CDS reduced omission errors by 38.3% (p < .0001, n = 120), 46.6% (p < .0001, n = 70), and 39.2% (p < .0001, n = 120) for low, low + interrupt and high complexity scenarios respectively. Incorrect CDS increased omission errors by 33.3% (p < .0001, n = 120), 24.5% (p < .009, n = 82), and 26.7% (p < .0001, n = 120). Participants made commission errors, 65.8% (p < .0001, n = 120), 53.5% (p < .0001, n = 82), and 51.7% (p < .0001, n = 120). Task complexity and interruptions had no impact on AB. This study found evidence of AB omission and commission errors in e-prescribing. Verification of CDS alerts is key to avoiding AB errors. However, interventions focused on this have had limited success to date. Clinicians should remain vigilant to the risks of CDS failures and verify CDS.

  2. Evaluation of the appropriate use of commonly prescribed fluoroquinolones and the risk of dysglycemia

    Directory of Open Access Journals (Sweden)

    Kabbara WK

    2015-04-01

    Full Text Available Wissam K Kabbara,1 Wijdan H Ramadan,1 Peggy Rahbany,2 Souhaila Al-Natour3 1Department of Pharmacy Practice, School of Pharmacy, Lebanese American University, Byblos, Lebanon; 2Children’s National Medical Center, Washington, DC, USA; 3Medex Pharmaceutical Company, Beirut, Lebanon Background: Fluoroquinolones are among the most widely prescribed antibiotics. However, concerns about increasing resistant microorganisms and the risk of dysglycemia associated with the use of these agents have emerged.Objective: The primary objective of the study was to evaluate the appropriate use of commonly prescribed fluoroquinolones, including appropriate indication, dose, dose adjustment in renal impairment, and duration of treatment. The secondary objective was to investigate the dysglycemic effect of fluoroquinolone use (hypoglycemia and/or hyperglycemia in diabetic and nondiabetic patients.Methods: A prospective observational study at a teaching hospital in Lebanon was conducted over a 6-month period. A total of 118 patients receiving broad-spectrum fluoroquinolones (levofloxacin, ciprofloxacin, and moxifloxacin were identified. Patients were mainly recruited from internal medicine floors and intensive care units.Results: The final percentage for the appropriate indication, dose, and duration of fluoroquinolone therapy was 93.2%, 74.6%, and 57.6%, respectively. A total of 57.1% of the patients did not receive the appropriate dose adjustment according to their level of renal impairment. In addition, dysglycemia occurred in both diabetic and nondiabetic patients. Dysglycemia was more frequently encountered with ciprofloxacin (50.0%, followed by levofloxacin (42.4% and moxifloxacin (7.6%. Hyperglycemia was more common than hypoglycemia in all groups. The highest incidence of hyperglycemia occurred with levofloxacin (70.0%, followed by ciprofloxacin (39.0% and moxifloxacin (33.3%. In contrast, hypoglycemia did not occur in the ciprofloxacin group, but it was

  3. Prescribing patterns of hydrocortisone in septic shock: a single-center experience of how surviving sepsis guidelines are interpreted and translated into bedside practice.

    Science.gov (United States)

    Contrael, Katlynd M; Killian, Alley J; Gregg, Sara R; Buchman, Timothy G; Coopersmith, Craig M

    2013-10-01

    The Surviving Sepsis Campaign suggests giving hydrocortisone to septic patients only if their "blood pressure is poorly responsive to fluid resuscitation and vasopressor therapy." Because the definition of "poorly responsive" is not provided, the purpose of this study was to identify prescribing triggers for hydrocortisone in septic shock. Retrospective chart review of patients with septic shock over 17 months, who received hydrocortisone, followed by a survey of all intensivists who attended in the study ICUs to determine whether provider attitudes matched clinical practice. Eight ICUs in an academic hospital and a hybrid academic/community hospital. A total of 155 patients with septic shock in whom vasopressors were initiated and hydrocortisone was prescribed. Ninety-nine patients (64%) were already receiving two vasopressors before hydrocortisone was prescribed. An additional 22 patients were on a single high-dose vasopressor prior to corticosteroid initiation. Of patients who survived to have their hydrocortisone dose changed, 57% had their corticosteroids tapered, whereas 43% were abruptly discontinued. Seventy-six percent of patients were no longer on vasopressors when the first dosing change was made. Twenty-seven out of 36 intensivists (75%) completed the survey. The majority (72%) defined "poorly responsive to vasopressors" as the presence of two vasopressors, and 70% stated that they required patients to be off vasopressors prior to altering the corticosteroid dose. Significant variability exists when corticosteroids are prescribed for septic shock, with the most common interpretation in our institution of "poorly responsive to fluid resuscitation and vasopressor therapy" being the presence of two vasopressors. The method and timing of corticosteroid discontinuation also differed among providers. Self-described prescribing patterns from intensivists closely matched their actual behavior, suggesting variability is due to differing interpretations of the

  4. Evaluation of lens dose in medulloblastoma radiotherapy

    International Nuclear Information System (INIS)

    Oliveira, F.L.; Vilela, E.C.; Sousa, S.A; Lima, F.F. de

    2007-01-01

    The improvement of the applied radiotherapy techniques in the cranial-spinal therapy, which is used in the cases of medulloblastoma, aims the reduction of the risks of future damages in enclosed critical agencies in the irradiation fields. This work aims to evaluate the lens doses due two common techniques used in medulloblastoma radiotherapy. For this, thermoluminescent dosimeters, previously calibrated, were located in an anthropomorphic phantom (ALDERSON - RANDON Laboratory), in the tumor and lens positions. The employed techniques were as following: (1) angled fields technique and (2) half-beam block technique. The phantom was irradiated five times in each technique with two lateral opposed fields in the brain with a total prescribed dose of 1.5 Gy, followed of two posterior spinal fields with the same prescribed dose, using a 6MV accelerator. The results showed that the doses in the first technique were 0.10 +- 0,04 Gy and, in second one, 0.09 +- 0,02 Gy. It was observed that, independent of the employed technique, the lens doses practically are the same. (author)

  5. WE-DE-201-11: Sensitivity and Specificity of Verification Methods Based On Total Reference Air Kerma (TRAK) Or On User Provided Dose Points for Graphically Planned Skin HDR Brachytherapy

    International Nuclear Information System (INIS)

    Damato, A; Devlin, P; Bhagwat, M; Buzurovic, I; Hansen, J; O’Farrell, D; Cormack, R

    2016-01-01

    Purpose: To investigate the sensitivity and specificity of a novel verification methodology for image-guided skin HDR brachytherapy plans using a TRAK-based reasonableness test, compared to a typical manual verification methodology. Methods: Two methodologies were used to flag treatment plans necessitating additional review due to a potential discrepancy of 3 mm between planned dose and clinical target in the skin. Manual verification was used to calculate the discrepancy between the average dose to points positioned at time of planning representative of the prescribed depth and the expected prescription dose. Automatic verification was used to calculate the discrepancy between TRAK of the clinical plan and its expected value, which was calculated using standard plans with varying curvatures, ranging from flat to cylindrically circumferential. A plan was flagged if a discrepancy >10% was observed. Sensitivity and specificity were calculated using as a criteria for true positive that >10% of plan dwells had a distance to prescription dose >1 mm different than prescription depth (3 mm + size of applicator). All HDR image-based skin brachytherapy plans treated at our institution in 2013 were analyzed. Results: 108 surface applicator plans to treat skin of the face, scalp, limbs, feet, hands or abdomen were analyzed. Median number of catheters was 19 (range, 4 to 71) and median number of dwells was 257 (range, 20 to 1100). Sensitivity/specificity were 57%/78% for manual and 70%/89% for automatic verification. Conclusion: A check based on expected TRAK value is feasible for irregularly shaped, image-guided skin HDR brachytherapy. This test yielded higher sensitivity and specificity than a test based on the identification of representative points, and can be implemented with a dedicated calculation code or with pre-calculated lookup tables of ideally shaped, uniform surface applicators.

  6. WE-DE-201-11: Sensitivity and Specificity of Verification Methods Based On Total Reference Air Kerma (TRAK) Or On User Provided Dose Points for Graphically Planned Skin HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Damato, A; Devlin, P; Bhagwat, M; Buzurovic, I; Hansen, J; O’Farrell, D; Cormack, R [Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: To investigate the sensitivity and specificity of a novel verification methodology for image-guided skin HDR brachytherapy plans using a TRAK-based reasonableness test, compared to a typical manual verification methodology. Methods: Two methodologies were used to flag treatment plans necessitating additional review due to a potential discrepancy of 3 mm between planned dose and clinical target in the skin. Manual verification was used to calculate the discrepancy between the average dose to points positioned at time of planning representative of the prescribed depth and the expected prescription dose. Automatic verification was used to calculate the discrepancy between TRAK of the clinical plan and its expected value, which was calculated using standard plans with varying curvatures, ranging from flat to cylindrically circumferential. A plan was flagged if a discrepancy >10% was observed. Sensitivity and specificity were calculated using as a criteria for true positive that >10% of plan dwells had a distance to prescription dose >1 mm different than prescription depth (3 mm + size of applicator). All HDR image-based skin brachytherapy plans treated at our institution in 2013 were analyzed. Results: 108 surface applicator plans to treat skin of the face, scalp, limbs, feet, hands or abdomen were analyzed. Median number of catheters was 19 (range, 4 to 71) and median number of dwells was 257 (range, 20 to 1100). Sensitivity/specificity were 57%/78% for manual and 70%/89% for automatic verification. Conclusion: A check based on expected TRAK value is feasible for irregularly shaped, image-guided skin HDR brachytherapy. This test yielded higher sensitivity and specificity than a test based on the identification of representative points, and can be implemented with a dedicated calculation code or with pre-calculated lookup tables of ideally shaped, uniform surface applicators.

  7. Fractionated or single-dose total body irradiation in 171 acute myeloblastic leukemias in first complete remission: is there a best choice?

    International Nuclear Information System (INIS)

    Resbeut, Michel; Cowen, Didier; Blaise, Didier; Gluckman, Eliane; Cosset, Jean-Marc; Rio, Bernard; Pene, Francoise; Milpied, Nicolas; Cuillere, Jean-Claude; Reiffers, Josy; Richaud, Pierre

    1995-01-01

    Purpose: To evaluate the importance of fractionating total body irradiation (TBI) in patients receiving an allogenic bone marrow transplant (BMT) for an acute myeloblastic leukemia (AML) in first complete remission (CR1). Methods and Materials: Between 1983 and 1990, 171 consecutive patients received either single dose TBI (STBI) (n = 65) or fractionated TBI (FTBI) (n = 106) after being conditioned with cyclophosphamide and before receiving a non-T-depleted Human Leucocyte Antigen (HLA)-identical marrow. Both groups were comparable except for date of BMT and diagnosis-to-BMT interval (D-BMT). Results: After 63 months median follow-up, transplant-related mortality (TRM), probability of relapse, and 5-year disease-free survival (DFS) were 0.38 and 0.27 (p = 0.04), 0.29 and 0.26 (p = 0.22), 0.43 and 0.56 (p = 0.06), respectively, for STBI and FTBI. The supposed influence of the schedule of TBI disappeared in the multivariate analysis: TRM was enhanced by severe acute graft vs. host disease (p = 0.0002), early years of transplant (before January 1, 1987) (p = 0.0003), and longer D-BMT intervals (p = 0.038). Relapse was linked to early years of transplant (p < 0.00001), and the absence of chronic GVHD (p = 0.007). Longer DFSs were observed for later years of transplant (after January 1, 1987 and later) (p = 0.001), milder acute GVHD (p = 0.005), and shorter D-BMT intervals (p = 0.045). Important improvements of the results were made during the 7-year observation period: TRM, probability of relapse, and DFS were, respectively, 0.36, 0.28, and 0.46 for patients transplanted before January 1, 1987 vs. 0.21, 0.15, and 0.67 after that date. Conclusion: Our data strongly suggest that allogenic BMT is the best postremission treatment for AML in CR1, and the results are better when BMT shortly follows the achievement of remission. The schedule of TBI was of little importance compared with the improvements made in the management of patients undergoing BMT during the 1980s, and

  8. Comparison of Psychotropic Drug Prescribing Quality between Zagreb, Croatia and Sarajevo, B&H.

    Science.gov (United States)

    Polić-Vižintin, Marina; Štimac, Danijela; Čatić, Tarik; Šostar, Zvonimir; Zelić, Ana; Živković, Krešimir; Draganić, Pero

    2014-12-01

    The purpose of this paper was to compare outpatient consumption and quality of psychotropic drug prescribing between Croatia and Bosnia & Herzegovina 2006-2010. Data on drug utilization from Zagreb Municipal Pharmacy and Sarajevo Public Pharmacy were used to calculate the number of defined daily doses (DDD) and DDD per 1000 inhabitants per day (DDD/TID) using the WHO Anatomical-Therapeutic-Chemical methodology. Total utilization of psychopharmaceuticals increased in both cities; however, it was higher in Zagreb than in Sarajevo throughout the study period. The utilization of psycholeptics increased in Zagreb by 2.4% (from 74.5 to 76.3 DDD/TID) and in Sarajevo by 3.8% (from 62.4 to 64.8 DDD/TID). The utilization of anxiolytics decreased in Zagreb by 2.1% and in Sarajevo by even 18.7%. The utilization of antidepressants increased in both cities with predominance of SSRI over TCA utilization, greater in Sarajevo (96.6%) than in Zagreb (10.2%). The anxiolytic/antidepressant ratio decreased by 11.1% in Zagreb (from 2.87 to 2.55) and by 58.7% in Sarajevo (from 5.66 to 2.34). Outpatient utilization of antipsychotics increased significantly in Sarajevo, predominated by typical ones, whereas in Zagreb the utilization of antipsychotics was stable, predominated by atypical ones. In Croatia and Bosnia & Herzegovina, there was an obvious tendency to follow western trends in drug prescribing, as demonstrated by the increased use of antidepressants and reduced use of anxiolytics. Despite some improvement observed in the prescribing quality, high use of antipsychotics with dominance of typical antipsychotics in Sarajevo points to the need of prescribing guidelines for antipsychotics.

  9. A combination of high dose rate (10X FFF/2400 MU/min/10 MV X-rays) and total low dose (0.5 Gy) induces a higher rate of apoptosis in melanoma cells in vitro and superior preservation of normal melanocytes.

    Science.gov (United States)

    Sarojini, Sreeja; Pecora, Andrew; Milinovikj, Natasha; Barbiere, Joseph; Gupta, Saakshi; Hussain, Zeenathual M; Tuna, Mehmet; Jiang, Jennifer; Adrianzen, Laura; Jun, Jaewook; Catello, Laurice; Sanchez, Diana; Agarwal, Neha; Jeong, Stephanie; Jin, Youngjin; Remache, Yvonne; Goy, Andre; Ndlovu, Alois; Ingenito, Anthony; Suh, K Stephen

    2015-10-01

    The aim of this study was to determine the apoptotic effects, toxicity, and radiosensitization of total low dose irradiation delivered at a high dose rate in vitro to melanoma cells, normal human epidermal melanocytes (HEM), or normal human dermal fibroblasts (HDF) and to study the effect of mitochondrial inhibition in combination with radiation to enhance apoptosis in melanoma cells. Cells irradiated using 10X flattening filter-free (FFF) 10 MV X-rays at a dose rate of 400 or 2400 MU/min and a total dose of 0.25-8 Gy were analyzed by cell/colony counting, MitoTracker, MTT, and DNA-damage assays, as well as by quantitative real-time reverse transcriptase PCR in the presence or absence of mitochondrial respiration inhibitors. A dose rate of 2400 MU/min killed on average five-fold more melanoma cells than a dose rate 400 MU/min at a total dose of 0.5 Gy and preserved 80% survival of HEM and 90% survival of HDF. Increased apoptosis at the 2400 MU/min dose rate is mediated by greater DNA damage, reduced cell proliferation, upregulation of apoptotic genes, and downregulation of cell cycle genes. HEM and HDF were relatively unharmed at 2400 MU/min. Radiation induced upregulation of mitochondrial respiration in both normal and cancer cells, and blocking the respiration with inhibitors enhanced apoptosis only in melanoma cells. A high dose rate with a low total dose (2400 MU/min, 0.5 Gy/10X FFF 10 MV X-rays) enhances radiosensitivity of melanoma cells while reducing radiotoxicity toward HEM and HDF. Selective cytotoxicity of melanoma cells is increased by blocking mitochondrial respiration.

  10. Dosimetry and verification of 60Co total body irradiation with human phantom and semiconductor diodes

    Directory of Open Access Journals (Sweden)

    Allahverdi Mahmoud

    2007-01-01

    Full Text Available Total Body Irradiation (TBI is a form of radiotherapy used for patients prior to bone marrow or stem cell transplant to destroy any undetectable cancer cells. The dosimetry characteristics of a 60 Co unit for TBI were studied and a simple method for the calculation of the prescribed dose for TBI is presented. Dose homogeneity was verified in a human phantom. Dose measurements were made in water phantom (30 x 30 x 30 cm 3 , using farmer ionization chamber (0.6 cc, TM30010, PTW and a parallel plate ionization chamber (TM23343, PTW. Point dose measurements for AP/PA irradiation were measured in a human phantom using silicon diodes (T60010L, PTW. The lung dose was measured with an ionization chamber (0.3 cc, TM31013. The validity of the proposed algorithm was checked at TBI distance using the human phantom. The accuracy of the proposed algorithm was within 3.5%. The dose delivered to the mid-lobe of the lung was 14.14 Gy and it has been reduced to 8.16 Gy by applying the proper shield. Dose homogeneity was within ±7% for all measured points. The results indicate that a good agreement between the total prescribed and calculated midplane doses can be achieved using this method. Therefore, it could be possible to use calculated data for TBI treatments.

  11. Can we influence prescribing patterns?

    Science.gov (United States)

    Sbarbaro, J A

    2001-09-15

    A variety of programming techniques and methods of training have been employed to change physician behavior. Didactic continuing medical education lectures and clinical guidelines have had minimal impact, although endorsement of national professional guidelines by local opinion leaders appears to have a positive influence on the impact of professional guidelines. Interactive, hands-on workshops, performance reporting, and peer/patient feedback are also effective. Changing prescribing habits has been equally difficult. Drug utilization letters involving both pharmacist and physician have more impact than do letters sent only to the physician. Academic detailing, when properly executed, has been consistently effective. When combined with these strategies, closed formularies become a powerful tool in changing prescribing behavior.

  12. Which prosthetic foot to prescribe?

    OpenAIRE

    De Asha, AR; Barnett, CT; Struchkov, V; Buckley, JG

    2017-01-01

    Introduction: \\ud Clinicians typically use findings from cohort studies to objectively inform judgements regarding the potential (dis)advantages of prescribing a new prosthetic device. However, before finalising prescription a clinician will typically ask a patient to 'try out' a change of prosthetic device while the patient is at the clinic. Observed differences in gait when using the new device should be the result of the device’s mechanical function, but could also conceivably be due to pa...

  13. Prescribing patterns in premenstrual syndrome

    Directory of Open Access Journals (Sweden)

    Jones Paul W

    2002-06-01

    Full Text Available Abstract Background Over 300 therapies have been proposed for premenstrual syndrome. To date there has been only one survey conducted in the UK of PMS treatments prescribed by GPs, a questionnaire-based study by the National Association of Premenstrual Syndrome in 1989. Since then, selective serotonin re-uptake inhibitors have been licensed for severe PMS/PMDD, and governmental recommendations to reduce the dosage of vitamin B6 (the first choice over-the-counter treatment for many women with PMS have been made. This study investigates the annual rates of diagnoses and prescribing patterns for premenstrual syndrome (1993–1998 within a computerised general practitioner database. Methods Retrospective survey of prescribing data for premenstrual syndrome between 1993–1998 using the General Practice Research Database for the West Midlands Region which contains information on 282,600 female patients Results Overall the proportion of women with a prescription-linked diagnosis of premenstrual syndrome has halved over the five years. Progestogens including progesterone were the most commonly recorded treatment for premenstrual syndrome during the whole study period accounting for over 40% of all prescriptions. Selective serotonin-reuptake inhibitors accounted for only 2% of the prescriptions in 1993 but rose to over 16% by 1998, becoming the second most commonly recorded treatment. Vitamin B6 accounted for 22% of the prescriptions in 1993 but dropped markedly between 1997 and 1998 to 11%. Conclusions This study shows a yearly decrease in the number of prescriptions linked to diagnoses for premenstrual syndrome. Progestogens including progesterone, is the most widely prescribed treatment for premenstrual syndrome despite the lack of evidence demonstrating their efficacy.

  14. Sorafenib prescribed by gastroenterologists and hepatologists for hepatocellular carcinoma

    Science.gov (United States)

    Kaplan, David E.; Mehta, Rajni; D’Addeo, Kathryn; Valderrama, Adriana; Taddei, Tamar H.

    2018-01-01

    Abstract Sorafenib is the only Food and Drug Administration (FDA)-approved first-line therapy shown to have survival benefit for patients with advanced hepatocellular carcinoma (HCC). Patients with advanced HCC are often but not exclusively transferred from non-oncologists to oncologists to initiate systemic therapy. The objective of this study was to assess whether sorafenib prescribing by non-oncologists has any impact on utilization, adverse effects, cost or outcome. This was a retrospective cohort study utilizing data from patients prescribed sorafenib for HCC within Veterans Health Administration hospitals with 100% chart abstraction to confirm HCC diagnosis, identify prescribing provider specialty (oncology versus gastroenterology/hepatology), and obtain data required for cancer staging by the Barcelona Clinic Liver Cancer (BCLC) system. The primary outcome was overall survival from the time of sorafenib prescription. A total of 4903 patients who prescribed sorafenib for HCC were identified, for whom 340 patients (6.9%) were prescribed drug by a non-oncologist (Onc). BCLC Stage, age, Child–Turcotte–Pugh score, and comorbidity indices were similar between patients prescribed sorafenib by oncologists and non-oncologists. Oncologists more often discontinued sorafenib due to progression, whereas non-oncologists were more likely to continue sorafenib until death resulting in greater pill utilization and cost. Overall survival in both unadjusted and multivariable models showed no significant impact of prescriber type on survival (222 vs 217 days, P = .96), confirmed with propensity-matched subcohorts. Similar survival outcomes were observed for patients with HCC prescribed sorafenib by non-oncologists and oncologists, suggesting that non-oncologists with expertise in the management of HCC can safely and effectively administer sorafenib. PMID:29369224

  15. Medicare Provider Data - Part D Prescriber

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Part D Prescriber Public Use File (PUF) provides information on prescription drugs prescribed by individual physicians and other health care providers and paid...

  16. Dutch Travel Health Nurses: Prepared to Prescribe?

    NARCIS (Netherlands)

    Overbosch, Femke W.; Koeman, Susan C.; van den Hoek, Anneke; Sonder, Gerard J. B.

    2012-01-01

    Background. In travel medicine, as in other specialties, independent prescribing of medication has traditionally been the domain of practitioners like physicians, dentists, and midwives. However, a 2011 ruling in the Netherlands expands independent prescribing and introduces supplementary

  17. The quality of outpatient antimicrobial prescribing

    DEFF Research Database (Denmark)

    Malo, Sara; Bjerrum, Lars; Feja, Cristina

    2013-01-01

    The aim of the study was to analyse and compare the quality of outpatient antimicrobial prescribing in Denmark and Aragón (in northeastern Spain), with the objective of assessing inappropriate prescribing....

  18. Failure-probability driven dose painting

    International Nuclear Information System (INIS)

    Vogelius, Ivan R.; Håkansson, Katrin; Due, Anne K.; Aznar, Marianne C.; Kristensen, Claus A.; Rasmussen, Jacob; Specht, Lena; Berthelsen, Anne K.; Bentzen, Søren M.

    2013-01-01

    Purpose: To demonstrate a data-driven dose-painting strategy based on the spatial distribution of recurrences in previously treated patients. The result is a quantitative way to define a dose prescription function, optimizing the predicted local control at constant treatment intensity. A dose planning study using the optimized dose prescription in 20 patients is performed.Methods: Patients treated at our center have five tumor subvolumes from the center of the tumor (PET positive volume) and out delineated. The spatial distribution of 48 failures in patients with complete clinical response after (chemo)radiation is used to derive a model for tumor control probability (TCP). The total TCP is fixed to the clinically observed 70% actuarial TCP at five years. Additionally, the authors match the distribution of failures between the five subvolumes to the observed distribution. The steepness of the dose–response is extracted from the literature and the authors assume 30% and 20% risk of subclinical involvement in the elective volumes. The result is a five-compartment dose response model matching the observed distribution of failures. The model is used to optimize the distribution of dose in individual patients, while keeping the treatment intensity constant and the maximum prescribed dose below 85 Gy.Results: The vast majority of failures occur centrally despite the small volumes of the central regions. Thus, optimizing the dose prescription yields higher doses to the central target volumes and lower doses to the elective volumes. The dose planning study shows that the modified prescription is clinically feasible. The optimized TCP is 89% (range: 82%–91%) as compared to the observed TCP of 70%.Conclusions: The observed distribution of locoregional failures was used to derive an objective, data-driven dose prescription function. The optimized dose is predicted to result in a substantial increase in local control without increasing the predicted risk of toxicity

  19. The differences in the incidence of diabetes mellitus and prediabetes according to the type of HMG-CoA reductase inhibitors prescribed in Korean patients.

    Science.gov (United States)

    Kim, Tong Min; Kim, Hyunah; Jeong, Yoo Jin; Baik, Sun Jung; Yang, So Jung; Lee, Seung-Hwan; Cho, Jae-Hyoung; Lee, Hyunyong; Yim, Hyeon Woo; Choi, In Young; Yoon, Kun-Ho; Kim, Hun-Sung

    2017-10-01

    Very few studies conducted in Korea have investigated the relationship between statins and the incidence of diabetes. Therefore, we analyzed the progression from normal blood glucose to prediabetes and then to diabetes mellitus (DM) according to the type, intensity, and dose of statin prescribed. Data of patients who were first prescribed statins between 2009 and 2011 were extracted from electronic medical records. Patients with normal blood glucose or prediabetes were observed for 4 years after initiation of statin therapy. A total of 2890 patients were included in our study and analyzed on the basis of the first statin they were prescribed. The incidence rate of DM in patients with prediabetes was 1.72 times that of patients with normal glucose levels (odds ratio = 1.72, 95% confidence interval = 1.41-2.10, P prediabetes, the incidence rate of prediabetes was significantly lower in patients prescribed pitavastatin (odds ratio = 0.62, 95% confidence interval = 0.40-0.96, P = .031) compared to that in patients prescribed atorvastatin. Regarding the progression from normal blood glucose or prediabetes to DM, there were no significant differences among all statins. Lower DM incidence in patients prescribed pitavastatin appears to be primarily because of the lower rate of progression from normal blood glucose to prediabetes. These findings indicate that avoiding statins because of DM risk is unjustified and that clinicians should prescribe statins from the appropriate potency group. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Inappropriate prescribing: criteria, detection and prevention.

    LENUS (Irish Health Repository)

    O'Connor, Marie N

    2012-06-01

    Inappropriate prescribing is highly prevalent in older people and is a major healthcare concern because of its association with negative healthcare outcomes including adverse drug events, related morbidity and hospitalization. With changing population demographics resulting in increasing proportions of older people worldwide, improving the quality and safety of prescribing in older people poses a global challenge. To date a number of different strategies have been used to identify potentially inappropriate prescribing in older people. Over the last two decades, a number of criteria have been published to assist prescribers in detecting inappropriate prescribing, the majority of which have been explicit sets of criteria, though some are implicit. The majority of these prescribing indicators pertain to overprescribing and misprescribing, with only a minority focussing on the underprescribing of indicated medicines. Additional interventions to optimize prescribing in older people include comprehensive geriatric assessment, clinical pharmacist review, and education of prescribers as well as computerized prescribing with clinical decision support systems. In this review, we describe the inappropriate prescribing detection tools or criteria most frequently cited in the literature and examine their role in preventing inappropriate prescribing and other related healthcare outcomes. We also discuss other measures commonly used in the detection and prevention of inappropriate prescribing in older people and the evidence supporting their use and their application in everyday clinical practice.

  1. Practices in prescribing protein substitutes for PKU in Europe

    DEFF Research Database (Denmark)

    Aguiar, A; Ahring, K; Almeida, M F

    2015-01-01

    BACKGROUND: There appears little consensus concerning protein requirements in phenylketonuria (PKU). METHODS: A questionnaire completed by 63 European and Turkish IMD centres from 18 countries collected data on prescribed total protein intake (natural/intact protein and phenylalanine-free protein...

  2. Airborne characterization of smoke marker ratios from prescribed burning

    Science.gov (United States)

    A. P. Sullivan; A. A. May; T. Lee; G. R. McMeeking; S. M. Kreidenweis; S. K. Akagi; R. J. Yokelson; S. P. Urbanski; J. L. Collett

    2014-01-01

    A Particle-Into-Liquid Sampler - Total Organic Carbon (PILS-TOC) and fraction collector system was flown aboard a Twin Otter aircraft sampling prescribed burning emissions in South Carolina in November 2011 to obtain smoke marker measurements. The fraction collector provided 2 min time-integrated offline samples for carbohydrate (i.e., smoke markers levoglucosan,...

  3. Potentially inappropriate prescribing and cost outcomes for older people: a national population study.

    LENUS (Irish Health Repository)

    Cahir, Caitriona

    2010-05-01

    Optimization of drug prescribing in older populations is a priority due to the significant clinical and economic costs of drug-related illness. This study aimed to: (i) estimate the prevalence of potentially inappropriate prescribing (PIP) in a national Irish older population using European specific explicit prescribing criteria; (ii) investigate the association between PIP, number of drug classes, gender and age and; (iii) establish the total cost of PIP.

  4. [Medication reconciliation errors according to patient risk and type of physician prescriber identified by prescribing tool used].

    Science.gov (United States)

    Bilbao Gómez-Martino, Cristina; Nieto Sánchez, Ángel; Fernández Pérez, Cristina; Borrego Hernando, Mª Isabel; Martín-Sánchez, Francisco Javier

    2017-01-01

    To study the frequency of medication reconciliation errors (MREs) in hospitalized patients and explore the profiles of patients at greater risk. To compare the rates of errors in prescriptions written by emergency physicians and ward physicians, who each used a different prescribing tool. Prospective cross-sectional study of a convenience sample of patients admitted to medical, geriatric, and oncology wards over a period of 6 months. A pharmacist undertook the medication reconciliation report, and data were analyzed for possible associations with risk factors or prescriber type (emergency vs ward physician). A total of 148 patients were studied. Emergency physicians had prescribed for 68 (45.9%) and ward physicians for 80 (54.1%). A total of 303 MREs were detected; 113 (76.4%) patients had at least 1 error. No statistically significant differences were found between prescriber types. Factors that conferred risk for a medication error were use polypharmacy (odds ratio [OR], 3.4; 95% CI, 1.2-9.0; P=.016) and multiple chronic conditions in patients under the age of 80 years (OR, 3.9; 95% CI, 1.1-14.7; P=.039). The incidence of MREs is high regardless of whether the prescriber is an emergency or ward physician. The patients who are most at risk are those taking several medications and those under the age of 80 years who have multiple chronic conditions.

  5. Clinical and symptomatological study of pigs subjected to a lethal dose of integral gamma irradiation; Etude clinique et symptomatologique chez le porc soumis a une irradiation gamma totale a dose letale

    Energy Technology Data Exchange (ETDEWEB)

    Vaiman, M; Guenet, J -L; Maas, J; Nizza, P

    1966-05-01

    Results are reported from a clinical and haematological study on a Corsican species of pigs wholly exposed to an approximately lethal dose of {gamma} radiation. The aim of this work was to examine the changes in the irradiation syndrome of irradiation for pigs to make it thus possible to devise further experiments, in particular in the therapeutic field. The dose received was 285 rads (measured as the absorption in the vertical antero-posterior medial plane). Data are presented on cyto-haematological changes in the blood circulating immediately after irradiation, and followed up to death, and changes in the medullary cytology after irradiation. The clinical picture of lethal radiation injury in swine is described. (authors) [French] Les auteurs rapportent les resultats d'une etude clinique et hematologique chez des porcs de race corse irradies in toto a dose sensiblement letale. Le but de cette etude etait de connaitre l'evolution du syndrome aigu d'irradiation chez le porc et de permettre ainsi le developpement d'experimentations ulterieures, en particulier dans le domaine therapeutique. La dose delivree etait de 285 rad (en dose absorbee au niveau du plan median vertical anteroposterieur. L'etude a porte essentiellement: 1. Sur les modifications cyclo-hematologiques du sang circulant immediatement apres l'irradiation, pour les differentes lignees cellulaires; l'evolution de ces modifications a ete notee jusqu'a la mort; 2. Sur les modifications de la cytologie medullaire apres irradiation (evolution du myelogramme et essai d'evaluation de la cellularite de la moelle osseuse);: 3. Sur les signes cliniques, d'ailleurs tres discrets, observes chez les porcs apres irradiation. (auteurs)

  6. Clinical and symptomatological study of pigs subjected to a lethal dose of integral gamma irradiation; Etude clinique et symptomatologique chez le porc soumis a une irradiation gamma totale a dose letale

    Energy Technology Data Exchange (ETDEWEB)

    Vaiman, M.; Guenet, J.-L.; Maas, J.; Nizza, P

    1966-05-01

    Results are reported from a clinical and haematological study on a Corsican species of pigs wholly exposed to an approximately lethal dose of {gamma} radiation. The aim of this work was to examine the changes in the irradiation syndrome of irradiation for pigs to make it thus possible to devise further experiments, in particular in the therapeutic field. The dose received was 285 rads (measured as the absorption in the vertical antero-posterior medial plane). Data are presented on cyto-haematological changes in the blood circulating immediately after irradiation, and followed up to death, and changes in the medullary cytology after irradiation. The clinical picture of lethal radiation injury in swine is described. (authors) [French] Les auteurs rapportent les resultats d'une etude clinique et hematologique chez des porcs de race corse irradies in toto a dose sensiblement letale. Le but de cette etude etait de connaitre l'evolution du syndrome aigu d'irradiation chez le porc et de permettre ainsi le developpement d'experimentations ulterieures, en particulier dans le domaine therapeutique. La dose delivree etait de 285 rad (en dose absorbee au niveau du plan median vertical anteroposterieur. L'etude a porte essentiellement: 1. Sur les modifications cyclo-hematologiques du sang circulant immediatement apres l'irradiation, pour les differentes lignees cellulaires; l'evolution de ces modifications a ete notee jusqu'a la mort; 2. Sur les modifications de la cytologie medullaire apres irradiation (evolution du myelogramme et essai d'evaluation de la cellularite de la moelle osseuse);: 3. Sur les signes cliniques, d'ailleurs tres discrets, observes chez les porcs apres irradiation. (auteurs)

  7. Patterns of patient specific dosimetry in total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Akino, Yuichi [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana 46202 (United States); Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871 (Japan); McMullen, Kevin P.; Das, Indra J. [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana 46202 (United States)

    2013-04-15

    Purpose: Total body irradiation (TBI) has been used for bone marrow transplant for hematologic and immune deficiency conditions. The goal of TBI is to deliver a homogeneous dose to the entire body, with a generally accepted range of dose uniformity being within {+-}10% of the prescribed dose. The moving table technique for TBI could make dose uniform in whole body by adjusting couch speed. However, it is difficult to accurately estimate the actual dose by calculation and hence in vivo dosimetry (IVD) is routinely performed. Here, the authors present patterns of patient-specific IVD in 161 TBI patients treated at our institution. Methods: Cobalt-60 teletherapy unit (Model C9 Cobalt-60 teletherapy unit, Picker X-ray Corporation) with customized moving bed (SITI Industrial Products, Inc., Fishers, IN) were used for TBI treatment. During treatment, OneDose{sup TM} (Sicel Technology, NC) Metal Oxide-silicon Semiconductor Field Effect Transistor detectors were placed at patient body surface; both entrance and exit side of the beam at patient head, neck, mediastinum, umbilicus, and knee to estimate midplane dose. When large differences (>10%) between the prescribed and measured dose were observed, dose delivery was corrected for subsequent fractions by the adjustment of couch speed and/or bolus placement. Under IRB exempt status, the authors retrospectively analyzed the treatment records of 161 patients who received TBI treatment between 2006 and 2011. Results: Across the entire cohort, the median {+-} SD (range) percent variance between calculated and measured dose for head, neck, mediastinum, umbilicus, and knee was -2.3 {+-} 10.2% (-66.2 to +35.3), 1.1 {+-} 11.5% (-62.2 to +40.3), -1.9 {+-} 9.5% (-66.4 to +46.6), -1.1 {+-} 7.2% (-35.2 to +42.9), and 3.4 {+-} 12.2% (-47.9 to +108.5), respectively. More than half of treatments were within {+-}10% of the prescribed dose for all anatomical regions. For 80% of treatments (10%-90%), dose at the umbilicus was within {+-}10

  8. A Validation Study of Homeopathic Prescribing and Patient Care Indicators

    Directory of Open Access Journals (Sweden)

    Munmun Koley

    2014-10-01

    Full Text Available A preliminary version of the homeopathic prescribing and patient care indicators was available. The instrument was modified further in this study with an intention to address formally its validity and reliability, audit prescriptions, identify areas of sub-optimal prescribing, and highlight target areas for improving the quality of practices. A cross-sectional study with record analysis was conducted on systematically sampled 377 patients of Mahesh Bhattacharyya Homeopathic Medical College and Hospital (MBHMC and H, Howrah, West Bengal, India. The outcome measures were homeopathic prescribing indicators (6 items and patient care indicators (5 items. Individualized homeopathic prescriptions predominated in the encounters. Areas demanding immediate attention were extremely poor labeling of drugs dispensed from the hospital pharmacy, improper record of case history and disease diagnosis, ongoing therapies, and investigational findings in the prescriptions. Internal consistency of the overall instrument was estimated to be good (Cronbach's alpha: Prescribing indicators 0.752 and patient care indicators 0.791. The prescribing indicators, except items 1 and 3, reflected acceptable item-corrected total correlations – Pearson's r from 0.58 (95% CI: 0.52-0.65 to 0.74 (95% CI: 0.69-0.78. The patient care indicators, except item 2, showed acceptable correlations – Pearson's r from 0.40 (95% CI: 0.31-0.48 to 0.82 (95% CI: 0.78-0.85. The instrument also showed high discriminant validity (prescribing indicators P<0.0001 and patient care indicators P<0.0001. Improper prescribing practice was quite rampant and corrective measures are warranted. The developed indicators appeared to be validated and reliable; however, they are amendable for further development.

  9. A Validation Study of Homeopathic Prescribing and Patient Care Indicators

    Science.gov (United States)

    Koley, Munmun; Saha, Subhranil; Ghosh, Shubhamoy; Nag, Goutam; Kundu, Monojit; Mondal, Ramkumar; Purkait, Rajib; Patra, Supratim

    2014-01-01

    A preliminary version of the homeopathic prescribing and patient care indicators was available. The instrument was modified further in this study with an intention to address formally its validity and reliability, audit prescriptions, identify areas of sub-optimal prescribing, and highlight target areas for improving the quality of practices. A cross-sectional study with record analysis was conducted on systematically sampled 377 patients of Mahesh Bhattacharyya Homeopathic Medical College and Hospital (MBHMC and H), Howrah, West Bengal, India. The outcome measures were homeopathic prescribing indicators (6 items) and patient care indicators (5 items). Individualized homeopathic prescriptions predominated in the encounters. Areas demanding immediate attention were extremely poor labeling of drugs dispensed from the hospital pharmacy, improper record of case history and disease diagnosis, ongoing therapies, and investigational findings in the prescriptions. Internal consistency of the overall instrument was estimated to be good (Cronbach's alpha: Prescribing indicators 0.752 and patient care indicators 0.791). The prescribing indicators, except items 1 and 3, reflected acceptable item-corrected total correlations – Pearson's r from 0.58 (95% CI: 0.52-0.65) to 0.74 (95% CI: 0.69-0.78). The patient care indicators, except item 2, showed acceptable correlations – Pearson's r from 0.40 (95% CI: 0.31-0.48) to 0.82 (95% CI: 0.78-0.85). The instrument also showed high discriminant validity (prescribing indicators P < 0.0001 and patient care indicators P < 0.0001). Improper prescribing practice was quite rampant and corrective measures are warranted. The developed indicators appeared to be validated and reliable; however, they are amendable for further development. PMID:25379474

  10. Prescribed burning supports grassland biodiversity - A multi-species study

    Science.gov (United States)

    Valkó, Orsolya; Deák, Balázs; Magura, Tibor; Török, Péter; Kelemen, András; Tóth, Katalin; Horváth, Roland; Nagy, Dávid; Debnár, Zsuzsanna; Zsigrai, György; Kapocsi, István; Tóthmérész, Béla

    2017-04-01

    During ancient times, fire was an important factor shaping European landscapes. Nowadays, prescribed burning can be one of the most effective conservation tools for the management of open landscapes, controlling dominant species, reducing accumulated litter or decreasing wildfire risk. In a prescribed burning experiment, we studied the effects of fire on dry alkaline grasslands. We tested whether autumn prescribed burning can be an alternative conservation measure in these grasslands. We selected six sites in Hungary: in three sites, prescribed burning was applied in November 2011, while three sites remained unburnt. We studied the effects of fire on soil characteristics, plant biomass and on the vegetation and arthropod assemblages (isopods, spiders, ground beetles and rove beetles). Soluble salt content increased significantly in the burnt sites, but soil pH, organic matter, potassium and phosphorous did not change. We found that prescribed fire had several positive effects from the nature conservation viewpoint. Diversity and the number of flowering shoots were higher, and the cover of the dominant grass was lower in the burnt sites. Graminoid biomass was lower, while total, green and forb biomass were higher in the burnt plots compared to the control ones. Our findings suggest that prescribed burning fire did not harm arthropods; species-level analyses showed that out of the most abundant invertebrate species, the abundance of ten was not affected, one decreased and one increased after burning. Our findings highlight that mosaic prescribed fire is a viable management tool in open landscapes, because it supports plant diversity and does not threaten arthropods.

  11. Dose evaluation of TPS according to treatment sites in IMRT

    International Nuclear Information System (INIS)

    Kim, Jin Man; Kim, Jong Sik; Hong, Chae Seon; Park, Ju Young; Park, Su Yeon; Ju, Sang Gyu

    2013-01-01

    This study executed therapy plans on prostate cancer (homogeneous density area) and lung cancer (non-homogeneous density area) using radiation treatment planning systems such as Pinnacle 3 (version 9.2, Philips Medical Systems, USA) and Eclipse (version 10.0, Varian Medical Systems, USA) in order to quantify the difference between dose calculation according to density in IMRT. The subjects were prostate cancer patients (n=5) and lung cancer patients (n=5) who had therapies in our hospital. Identical constraints and optimization process according to the Protocol were administered on the subjects. For the therapy plan of prostate cancer patients, 10 MV and 7Beam were used and 2.5 Gy was prescribed in 28 fx to make 70 Gy in total. For lung cancer patients, 6 MV and 6Beam were used and 2 Gy was prescribed in 33 fx to make 66 Gy in total. Through two therapy planning systems, maximum dose, average dose, and minimum dose of OAR (Organ at Risk) of CTV, PTV and around tumor were investigated. In prostate cancer, both therapy planning systems showed within 2% change of dose of CTV and PTV and normal organs (Bladder, Both femur and Rectum out) near the tumor satisfied the dose constraints. In lung cancer, CTV and PTV showed less than 2% changes in dose and normal organs (Esophagus, Spinal cord and Both lungs) satisfied dose restrictions. However, the minimum dose of Eclipse therapy plan was 1.9% higher in CTV and 3.5% higher in PTV, and in case of both lungs there was 3.0% difference at V5 Gy. Each TPS according to the density satisfied dose limits of our hospital proving the clinical accuracy. It is considered more accurate and precise therapy plan can be made if studies on treatment planning for diverse parts and the application of such TPS are made

  12. Variations in Metformin Prescribing for Type 2 Diabetes.

    Science.gov (United States)

    Goldberg, Tiffany; Kroehl, Miranda E; Suddarth, Kathleen Heist; Trinkley, Katy E

    2015-01-01

    Reasons for suboptimal metformin prescribing are unclear, but may be due to perceived risk of lactic acidosis. The purpose of this study is to describe provider attitudes regarding metformin prescribing in various patient situations. An anonymous, electronic survey was distributed electronically to 76 health care providers across the nation. The 14-item survey contained demographic questions and questions related to prescribing of metformin for T2DM in various patient situations, including suboptimal glycemic control, alcohol use, history of lactic acidosis, and varying degrees of severity for certain health conditions, including renal and hepatic dysfunction, chronic obstructive pulmonary disease, and heart failure. There were a total of 100 respondents. For suboptimal glycemic control, most providers (75%) would increase metformin from 1500 to 2000 mg daily; however, 25% would add an alternate agent, such as a sulfonylurea (18%) or dipeptidyl peptidase-4 inhibitor (7%). Although 51% of providers would stop metformin based on serum creatinine thresholds, the remainder would rely on glomerular filtration rate thresholds of <60 mL/min (15%), <30 mL/min (33%), or <15 mL/min (1%) to determine when to stop metformin. For heart failure, 45% of providers would continue metformin as currently prescribed regardless of severity. Most providers would adjust metformin for varying severity of hepatic dysfunction (74%) and alcohol abuse (40%). Despite evidence supporting the cardiovascular benefits of metformin, provider attitudes toward prescribing metformin are suboptimal in certain patient situations and vary greatly by provider. © Copyright 2015 by the American Board of Family Medicine.

  13. Empty virions in AAV8 vector preparations reduce transduction efficiency and may cause total viral particle dose-limiting side effects

    Directory of Open Access Journals (Sweden)

    Kai Gao

    2014-01-01

    Full Text Available Empty virions are inadvertent by-products of recombinant adeno-associated virus (rAAV packaging process, resulting in vector lots with mixtures of full and empty virions at variable ratios. Impact of empty virions on the efficiency and side effects of rAAV transduction has not been well characterized. Here, we generated partially and completely empty AAV8 virions, fully packaged rAAV8 lots, and mixtures of empty and fully packaged virions with variable ratios of empty virions. The aforementioned dosing formulations of rAAV8 expressing either cellular (EGFP (enhanced green fluorescent protein or nuclear-targeted (n LacZ or secreted (human α1-antitrypsin (hA1AT reporter genes were intravenously injected into two different mouse strains, followed by analyses of transgene expressions and serum alanine aminotransferase (ALT levels at different time points. We found that addition of empty particles to the fixed doses of rAAV8 preparations repressed liver transduction up to 64% (serum hA1AT and 44% (nLacZ in C57BL/6 mice, respectively. The similar trend in inhibiting EGFP expression together with concurrent elevations of serum ALT levels were observed in the BALB/c mice, indicating that empty particles may also exacerbate side effects of rAAV8 EGFP transduction. Our results suggest that removal of empty particles from rAAV preparations may improve efficacy and safety of AAV in clinical applications.

  14. A Novel Design for Drug-Drug Interaction Alerts Improves Prescribing Efficiency.

    Science.gov (United States)

    Russ, Alissa L; Chen, Siying; Melton, Brittany L; Johnson, Elizabette G; Spina, Jeffrey R; Weiner, Michael; Zillich, Alan J

    2015-09-01

    Drug-drug interactions (DDIs) are common in clinical care and pose serious risks for patients. Electronic health records display DDI alerts that can influence prescribers, but the interface design of DDI alerts has largely been unstudied. In this study, the objective was to apply human factors engineering principles to alert design. It was hypothesized that redesigned DDI alerts would significantly improve prescribers' efficiency and reduce prescribing errors. In a counterbalanced, crossover study with prescribers, two DDI alert designs were evaluated. Department of Veterans Affairs (VA) prescribers were video recorded as they completed fictitious patient scenarios, which included DDI alerts of varying severity. Efficiency was measured from time-stamped recordings. Prescribing errors were evaluated against predefined criteria. Efficiency and prescribing errors were analyzed with the Wilcoxon signed-rank test. Other usability data were collected on the adequacy of alert content, prescribers' use of the DDI monograph, and alert navigation. Twenty prescribers completed patient scenarios for both designs. Prescribers resolved redesigned alerts in about half the time (redesign: 52 seconds versus original design: 97 seconds; p<.001). Prescribing errors were not significantly different between the two designs. Usability results indicate that DDI alerts might be enhanced by facilitating easier access to laboratory data and dosing information and by allowing prescribers to cancel either interacting medication directly from the alert. Results also suggest that neither design provided adequate information for decision making via the primary interface. Applying human factors principles to DDI alerts improved overall efficiency. Aspects of DDI alert design that could be further enhanced prior to implementation were also identified.

  15. A 0.18 micrometer CMOS Thermopile Readout ASIC Immune to 50 MRAD Total Ionizing Dose (SI) and Single Event Latchup to 174MeV-cm(exp 2)/mg

    Science.gov (United States)

    Quilligan, Gerard T.; Aslam, Shahid; Lakew, Brook; DuMonthier, Jeffery J.; Katz, Richard B.; Kleyner, Igor

    2014-01-01

    Radiation hardened by design (RHBD) techniques allow commercial CMOS circuits to operate in high total ionizing dose and particle fluence environments. Our radiation hard multi-channel digitizer (MCD) ASIC (Figure 1) is a versatile analog system on a chip (SoC) fabricated in 180nm CMOS. It provides 18 chopper stabilized amplifier channels, a 16- bit sigma-delta analog-digital converter (SDADC) and an on-chip controller. The MCD was evaluated at Goddard Space Flight Center and Texas A&M University's radiation effects facilities and found to be immune to single event latchup (SEL) and total ionizing dose (TID) at 174 MeV-cm(exp 2)/mg and 50 Mrad (Si) respectively.

  16. Characterization of Phenolic Compounds in Pinus laricio Needles and Their Responses to Prescribed Burnings

    Directory of Open Access Journals (Sweden)

    Lila Ferrat

    2007-07-01

    Full Text Available Fire is a dominant ecological factor in Mediterranean-type ecosystems. Management strategies include prescribed (controlled burning, which has been used in the management of several species, such as Pinus nigra ssp laricio var. Corsicana, a pine endemic to Corsica of great ecological and economic importance. The effects of prescribed burning on Pinus laricio have been little studied. The first aim of this study was to characterize total and simple phenolic compounds in Pinus laricio. The second aim was to understand: i the short term (one to three months and medium term (three years effects of prescribed burning, and ii the effects of periodic prescribed burning on the production of phenolic compounds in Pinus laricio. The first result of this study is the presence of total and simple phenolic compounds in the needles of Pinus laricio. 3-Vanillyl propanol is the major compound. After a prescribed burning, the synthesis of total phenolic compounds increases in Pinus laricio for a period of three months. Total phenolic compounds could be used as bioindicators for the short-term response of Pinus laricio needles to prescribed burning. Simple phenolic compounds do not seem to be good indicators of the impact of prescribed burning because prescribed burnings are low in intensity.

  17. Characterization of phenolic compounds in Pinus laricio needles and their responses to prescribed burnings.

    Science.gov (United States)

    Cannac, Magali; Pasqualini, Vanina; Greff, Stéphane; Fernandez, Catherine; Ferrat, Lila

    2007-07-30

    Fire is a dominant ecological factor in Mediterranean-type ecosystems. Management strategies include prescribed (controlled) burning, which has been used in the management of several species, such as Pinus nigra ssp laricio var. Corsicana, a pine endemic to Corsica of great ecological and economic importance. The effects of prescribed burning on Pinus laricio have been little studied. The first aim of this study was to characterize total and simple phenolic compounds in Pinus laricio. The second aim was to understand: i) the short term (one to three months) and medium term (three years) effects of prescribed burning, and ii) the effects of periodic prescribed burning on the production of phenolic compounds in Pinus laricio. The first result of this study is the presence of total and simple phenolic compounds in the needles of Pinus laricio. 3-Vanillyl propanol is the major compound. After a prescribed burning, the synthesis of total phenolic compounds increases in Pinus laricio for a period of three months. Total phenolic compounds could be used as bioindicators for the short-term response of Pinus laricio needles to prescribed burning. Simple phenolic compounds do not seem to be good indicators of the impact of prescribed burning because prescribed burnings are low in intensity.

  18. Topical antibiotic monotherapy prescribing practices in acne vulgaris.

    Science.gov (United States)

    Hoover, William D; Davis, Scott A; Fleischer, Alan B; Feldman, Steven R

    2014-04-01

    The aim of this study is to evaluate the frequency of dosing topical antibiotics as monotherapy in the treatment of acne vulgaris, and physician specialty prescribing these medications. This study is a retrospective review of all visits with a sole diagnosis of acne vulgaris (ICD-9-CM code 706.1) found on the National Ambulatory Medical Care Survey (NAMCS) in 1993-2010. We recorded the number of visits surveyed where acne vulgaris was the sole diagnosis, number of visits where topical antibiotics were the only treatment prescribed, and the specialty of physician in each encounter. Topical erythromycin or clindamycin were the sole medication prescribed in 0.81% of the visits recorded, with 60% of these prescriptions arising from dermatologists and 40% from non-dermatologists. The trend of prescribing topical antibiotic monotherapy is declining (p acnes to topical antibiotic regimens has led to the need to re-evaluate the use of topical antibiotics in the treatment of acne vulgaris. While the rate of topical antibiotic monotherapy is declining, their use should be reserved for situations where the direct need for antibiotics arises. If a clinician feels that antibiotics are a necessary component to acne therapy, they should be used as part of a combination regimen.

  19. Inappropriate prescribing in geriatric patients.

    LENUS (Irish Health Repository)

    Barry, Patrick J

    2012-02-03

    Inappropriate prescribing in older people is a common condition associated with significant morbidity, mortality, and financial costs. Medication use increases with age, and this, in conjunction with an increasing disease burden, is associated with adverse drug reactions. This review outlines why older people are more likely to develop adverse drug reactions and how common the problem is. The use of different tools to identify and measure the problem is reviewed. Common syndromes seen in older adults (eg, falling, cognitive impairment, sleep disturbance) are considered, and recent evidence in relation to medication use for these conditions is reviewed. Finally, we present a brief summary of significant developments in the recent literature for those caring for older people.

  20. A randomized trial of the effect of low dose epinephrine infusion in addition to tranexamic acid on blood loss during total hip arthroplasty

    DEFF Research Database (Denmark)

    Jans, Ø.; Grevstad, U.; Mandoe, H.

    2016-01-01

    procedure. Intraoperative tranexamic acid (TXA) was administered to all subjects. The primary outcome was intraoperative blood loss directly measured by drains and weighing swabs. Secondary outcome was total blood loss at 24 h postoperatively calculated using the Gross formula. Results: Of 106 subjects...

  1. Treatment verification and in vivo dosimetry for total body irradiation using thermoluminescent and semiconductor detectors

    International Nuclear Information System (INIS)

    Oliveira, F.F.; Amaral, L.L.; Costa, A.M.; Netto, T.G.

    2014-01-01

    The objective of this work is the characterization of thermoluminescent and semiconductor detectors and their applications in treatment verification and in vivo dosimetry for total body irradiation (TBI) technique. Dose measurements of TBI treatment simulation performed with thermoluminescent detectors inserted in the holes of a “Rando anthropomorphic phantom” showed agreement with the prescribed dose. For regions of the upper and lower chest where thermoluminescent detectors received higher doses it was recommended the use of compensating dose in clinic. The results of in vivo entrance dose measurements for three patients are presented. The maximum percentual deviation between the measurements and the prescribed dose was 3.6%, which is consistent with the action level recommended by the International Commission on Radiation Units and Measurements (ICRU), i.e., ±5%. The present work to test the applicability of a thermoluminescent dosimetric system and of a semiconductor dosimetric system for performing treatment verification and in vivo dose measurements in TBI techniques demonstrated the value of these methods and the applicability as a part of a quality assurance program in TBI treatments. - Highlights: • Characterization of a semiconductor dosimetric system. • Characterization of a thermoluminescent dosimetric system. • Application of the TLDs for treatment verification in total body irradiation treatments. • Application of semiconductor detectors for in vivo dosimetry in total body irradiation treatments. • Implementation of in vivo dosimetry as a part of a quality assurance program in radiotherapy

  2. Nurse prescribing in dermatology: doctors' and non-prescribing nurses' views.

    Science.gov (United States)

    Stenner, Karen; Carey, Nicola; Courtenay, Molly

    2009-04-01

    This paper is a report of a study conducted to explore doctor and non-prescribing nurse views about nurse prescribing in the light of their experience in dermatology. The cooperation of healthcare professionals and peers is of key importance in enabling and supporting nurse prescribing. Lack of understanding of and opposition to nurse prescribing are known barriers to its implementation. Given the important role they play, it is necessary to consider how the recent expansion of nurse prescribing rights in England impacts on the views of healthcare professionals. Interviews with 12 doctors and six non-prescribing nurses were conducted in 10 case study sites across England between 2006 and 2007. Participants all worked with nurses who prescribed for patients with dermatological conditions in secondary or primary care. Thematic analysis was conducted on the interview data. Participants were positive about their experiences of nurse prescribing having witnessed benefits from it, but had reservations about nurse prescribing in general. Acceptance was conditional upon the nurses' level of experience, awareness of their own limitations and the context in which they prescribed. Fears that nurses would prescribe beyond their level of competence were expected to reduce as understanding and experience of nurse prescribing increased. Indications are that nurse prescribing can be acceptable to doctors and nurses so long as it operates within recommended parameters. Greater promotion and assessment of standards and criteria are recommended to improve understanding and acceptance of nurse prescribing.

  3. Quality Improvement Initiative to Decrease Variability of Emergency Physician Opioid Analgesic Prescribing

    Directory of Open Access Journals (Sweden)

    John H. Burton

    2016-05-01

    Full Text Available Introduction: Addressing pain is a crucial aspect of emergency medicine. Prescription opioids are commonly prescribed for moderate to severe pain in the emergency department (ED; unfortunately, prescribing practices are variable. High variability of opioid prescribing decisions suggests a lack of consensus and an opportunity to improve care. This quality improvement (QI initiative aimed to reduce variability in ED opioid analgesic prescribing. Methods: We evaluated the impact of a three-part QI initiative on ED opioid prescribing by physicians at seven sites. Stage 1: Retrospective baseline period (nine months. Stage 2: Physicians were informed that opioid prescribing information would be prospectively collected and feedback on their prescribing and that of the group would be shared at the end of the stage (three months. Stage 3: After physicians received their individual opioid prescribing data with blinded comparison to the group means (from Stage 2 they were informed that individual prescribing data would be unblinded and shared with the group after three months. The primary outcome was variability of the standard error of the mean and standard deviation of the opioid prescribing rate (defined as number of patients discharged with an opioid divided by total number of discharges for each provider. Secondary observations included mean quantity of pills per opioid prescription, and overall frequency of opioid prescribing. Results: The study group included 47 physicians with 149,884 ED patient encounters. The variability in prescribing decreased through each stage of the initiative as represented by the distributions for the opioid prescribing rate: Stage 1 mean 20%; Stage 2 mean 13% (46% reduction, p<0.01, and Stage 3 mean 8% (60% reduction, p<0.01. The mean quantity of pills prescribed per prescription was 16 pills in Stage 1, 14 pills in Stage 2 (18% reduction, p<0.01, and 13 pills in Stage 3 (18% reduction, p<0.01. The group mean

  4. An electronic intervention to improve safety for pain patients co-prescribed chronic opioids and benzodiazepines.

    Science.gov (United States)

    Zaman, Tauheed; Rife, Tessa L; Batki, Steven L; Pennington, David L

    2018-03-29

    Co-prescribing opioids and benzodiazepines increases overdose risk. A paucity of literature exists evaluating strategies to improve safety of co-prescribing. This study evaluated an electronic intervention to improve safety for patients co-prescribed chronic opioids for pain and benzodiazepines at 3 and 6 months. A prospective cohort study was conducted from December 2015 through May 2016 at San Francisco Veterans Affairs Health Care System. A clinical dashboard identified 145 eligible patients prescribed chronic opioids and benzodiazepines. Individualized taper and safety recommendations were communicated to prescribers via electronic medical record progress note and encrypted e-mail at baseline. Primary outcome was number of patients co-prescribed chronic opioids and benzodiazepines. Secondary outcomes included daily dose of opioids and benzodiazepines and number prescribed ≥100 mg morphine equivalent daily dose. Safety outcomes included number with opioid overdose education and naloxone distribution, annual urine drug screening, annual prescription drug monitoring program review, and signed opioid informed consent. Linear mixed models and generalized estimating equations were used to examine within-group change in outcomes between baseline and 3 and 6 months. Among the 145 patients, mean (standard deviation) age was 62 (11) years and 91.7% (133/145) were male. Number co-prescribed significantly decreased from 145/145 (100%) at baseline to 93/139 (67%) at 6-month follow-up (odds ratio [OR] = 0.53, 95% confidence interval [CI]: 0.34-0.81, P = .003). Mean opioid and benzodiazepine doses significantly decreased from 84.61 to 65.63 mg (95% CI: 8.32-27.86, P improve safety for patients co-prescribed chronic opioids for pain and benzodiazepines.

  5. Medication prescribing errors in the medical intensive care unit of Tikur Anbessa Specialized Hospital, Addis Ababa, Ethiopia.

    Science.gov (United States)

    Sada, Oumer; Melkie, Addisu; Shibeshi, Workineh

    2015-09-16

    Medication errors (MEs) are important problems in all hospitalized populations, especially in intensive care unit (ICU). Little is known about the prevalence of medication prescribing errors in the ICU of hospitals in Ethiopia. The aim of this study was to assess medication prescribing errors in the ICU of Tikur Anbessa Specialized Hospital using retrospective cross-sectional analysis of patient cards and medication charts. About 220 patient charts were reviewed with a total of 1311 patient-days, and 882 prescription episodes. 359 MEs were detected; with prevalence of 40 per 100 orders. Common prescribing errors were omission errors 154 (42.89%), 101 (28.13%) wrong combination, 48 (13.37%) wrong abbreviation, 30 (8.36%) wrong dose, wrong frequency 18 (5.01%) and wrong indications 8 (2.23%). The present study shows that medication errors are common in medical ICU of Tikur Anbessa Specialized Hospital. These results suggest future targets of prevention strategies to reduce the rate of medication error.

  6. Prescribing Safety in Ambulatory Care: Physician Perspectives

    National Research Council Canada - National Science Library

    Rundall, Thomas G; Hsu, John; Lafata, Jennifer E; Fung, Vicki; Paez, Kathryn A; Simpkins, Jan; Simon, Steven R; Robinson, Scott B; Uratsu, Connie; Gunter, Margaret J; Soumerai, Stephen B; Selby, Joseph V

    2005-01-01

    .... We asked about current safety practices, perceptions of ambulatory prescribing safety. Using a content analysis approach, three investigators independently coded responses into thematic categories...

  7. Stereotactic intracranial radiotherapy: Dose prescription

    International Nuclear Information System (INIS)

    Schlienger, M.; Lartigau, E.; Nataf, F.; Mornex, F.; Latorzeff, I.; Lisbona, A.; Mahe, M.

    2012-01-01

    The aim of this article was the study of the successive steps permitting the prescription of dose in stereotactic intracranial radiotherapy, which includes radiosurgery and fractionated stereotactic radiotherapy. The successive steps studied are: the choice of stereotactic intracranial radiotherapy among the therapeutic options, based on curative or palliative treatment intent, then the selection of lesions according to size/volume, pathological type and their number permitting the choice between radiosurgery or fractionated stereotactic radiotherapy, which have the same methodological basis. Clinical experience has determined the level of dose to treat the lesions and limit the irradiation of healthy adjacent tissues and organs at risk structures. The last step is the optimization of the different parameters to obtain a safe compromise between the lesion dose and healthy adjacent structures. Study of dose-volume histograms, coverage indices and 3D imaging permit the optimization of irradiation. For lesions close to or included in a critical area, the prescribed dose is planned using the inverse planing method. Implementation of the successively described steps is mandatory to insure the prescription of an optimized dose. The whole procedure is based on the delineation of the lesion and adjacent healthy tissues. There are sometimes difficulties to assess the delineation and the volume of the target, however improvement of local control rates and reduction of secondary effects are the proof that the totality of the successive procedures are progressively improved. In practice, stereotactic intracranial radiotherapy is a continually improved treatment method, which constantly benefits from improvements in the choice of indications, imaging, techniques of irradiation, planing/optimization methodology and irradiation technique and from data collected from prolonged follow-up. (authors)

  8. Benefits of online in vivo dosimetry for single-fraction total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Eaton, David J., E-mail: davideaton@nhs.net [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom); Warry, Alison J. [Department of Radiotherapy Physics, University College London Hospital, London (United Kingdom); Trimble, Rachel E.; Vilarino-Varela, Maria J.; Collis, Christopher H. [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom)

    2014-01-01

    Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013, with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources.

  9. Benefits of online in vivo dosimetry for single-fraction total body irradiation

    International Nuclear Information System (INIS)

    Eaton, David J.; Warry, Alison J.; Trimble, Rachel E.; Vilarino-Varela, Maria J.; Collis, Christopher H.

    2014-01-01

    Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013, with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources

  10. Linac-based total body irradiation (TBI) with volumetric modulated arc therapy (VMAT)

    Science.gov (United States)

    Tas, B.; Durmus, I. F.; Okumus, A.; Uzel, O. E.

    2017-02-01

    To evaluate dose distribution of Volumetric modulated arc therapy (VMAT) planning tecnique using Versa HD® lineer accelerator to deliver Total Body Irradiation (TBI) on the coach. Eight TBI patient's Treatment Planning System (TPS) were performed with dual arc VMAT for each patient. The VMAT-TBI consisted of three isocentres and three dual overlapping arcs. The prescribed dose was 12 Gy. Mean dose to lung and kidney were restricted less than 10 Gy and max. dose to lens were restricted less than 6 Gy. The plans were verified using 2D array and ion chamber. The comparison between calculation and measurement were made by γ-index analysis and absolute dose. An average total delivery time was determined 923±34 seconds and an average MU was determined 2614±228 MUs for dual arc VMAT. Mean dose to lungs was 9.7±0.2 Gy, mean dose to kidneys was 8.8±0.3 Gy, max. dose to lens was 5.5±0.3 Gy and max. dose was 14.6±0.3 Gy, HI of PTV was 1.13±0.2, mean dose to PTV was 12.6±1.5 Gy and mean γ-index pass rate was %97.1±1.9. The results show that the tecnique for TBI using VMAT on the treatment coach is feasible.

  11. Nudging guideline-concordant antibiotic prescribing: a randomized clinical trial.

    Science.gov (United States)

    Meeker, Daniella; Knight, Tara K; Friedberg, Mark W; Linder, Jeffrey A; Goldstein, Noah J; Fox, Craig R; Rothfeld, Alan; Diaz, Guillermo; Doctor, Jason N

    2014-03-01

    "Nudges" that influence decision making through subtle cognitive mechanisms have been shown to be highly effective in a wide range of applications, but there have been few experiments to improve clinical practice. To investigate the use of a behavioral "nudge" based on the principle of public commitment in encouraging the judicious use of antibiotics for acute respiratory infections (ARIs). Randomized clinical trial in 5 outpatient primary care clinics. A total of 954 adults had ARI visits during the study timeframe: 449 patients were treated by clinicians randomized to the posted commitment letter (335 in the baseline period, 114 in the intervention period); 505 patients were treated by clinicians randomized to standard practice control (384 baseline, 121 intervention). The intervention consisted of displaying poster-sized commitment letters in examination rooms for 12 weeks. These letters, featuring clinician photographs and signatures, stated their commitment to avoid inappropriate antibiotic prescribing for ARIs. Antibiotic prescribing rates for antibiotic-inappropriate ARI diagnoses in baseline and intervention periods, adjusted for patient age, sex, and insurance status. Baseline rates were 43.5% and 42.8% for control and poster, respectively. During the intervention period, inappropriate prescribing rates increased to 52.7% for controls but decreased to 33.7% in the posted commitment letter condition. Controlling for baseline prescribing rates, we found that the posted commitment letter resulted in a 19.7 absolute percentage reduction in inappropriate antibiotic prescribing rate relative to control (P = .02). There was no evidence of diagnostic coding shift, and rates of appropriate antibiotic prescriptions did not diminish over time. Displaying poster-sized commitment letters in examination rooms decreased inappropriate antibiotic prescribing for ARIs. The effect of this simple, low-cost intervention is comparable in magnitude to costlier, more

  12. Drug prescribing and use among elderly people in Spain.

    Science.gov (United States)

    Mas, X; Laporte, J R; Frati, M E; Busquet, L; Arnau, J M; Ibañez, L; Séculi, E; Capellà, D; Arbonés, G

    1983-05-01

    As a result of the lack of an adequate regulation, the supply and the use of medicines is irrational in Spain. In order to know the characteristics of the prescription and use of drugs among the elderly, two drug utilization studies were carried out. The first study was an analysis of 981 prescriptions from an outpatient clinic of the Spanish Social Security. The results show that a high proportion of fixed-dose combinations were prescribed and that drugs without any demonstrated therapeutic value are often prescribed for the elderly. The second study was a survey of 389 individuals randomly chosen among people affiliated with a pensioners' club. The results show that drug use is highly prevalent among the elderly, that many medicines without any demonstrated benefit are being taken, and that potentially harmful drugs were being used by a high proportion of patients without medical follow-up. The prevalence of the use of some particular groups of drugs is also presented.

  13. A possible method using baseline hormonal levels to prescribe the appropriate oral therapeutic radioiodine dosage for Graves' disease

    International Nuclear Information System (INIS)

    Nakajo, Masayuki; Tsuchimochi, Shinsaku; Jinguji, Megumi; Tanabe, Hiroaki; Umanodan, Tomoichi; Nakabeppu, Yoshiaki

    2007-01-01

    The purpose of this study was to retrospectively examine the correlations of hormonal ratios with radioiodine I-131 therapeutic parameters and the potentiality of prescribing the therapeutic I-131 target dosage for an individual patient with Graves' disease using baseline serum levels of thyroid hormones. Serum T3, T4, and FT4 levels 6 and 12 months after I-131 therapy/baseline levels (hormonal ratios) were calculated for a total of 68 therapeutic courses in 57 patients with Graves' disease. The therapeutic parameters were absorbed dose (Gy), dose concentration (μCi/g) and oral dose (mCi). Linear regression analysis was performed for correlating hormonal ratios (X) and therapeutic parameters (Y). Significant (P<0.05) negative correlations of the hormonal ratios were observed with absorbed dose (R -0.50 for T3, -0.61 for T4, and -0.46 for FT4 at 6 months, and -0.29 for T3, -0.44 for T4 at 12 months) and dose concentration (R -0.57 for T3, -0.58 for T4, and -0.49 for FT4 at 6 months and -0.27 for T3, -0.27 for T4 at 12 months), but not with oral dose at 6 months and 12 months or the absorbed dose and dose concentration for FT4 at 12 months. The correlations were higher at 6 months than at 12 months and in serum T4 than in serum T3 and FT4. The formulae for serum T4 at 6 months were as follows: Y (Gy)=109-53X and Y (μCi/g)=109-52X. These results suggest that the hormonal ratios are significantly correlated with the absorbed dose and dose concentration. The formulae for serum T4 at 6 months may serve to prescribe the individual oral dosage for Graves' disease, although the correlation coefficients are about -0.6. (author)

  14. ETHICAL PRACTICES IN DRUG PRESCRIBING. A COMPARATIVE STUDY BETWEEN DOCTORS’ AND PHARMACISTS’ OPINION ABOUT DRUG PRESCRIBING IN ROMANIA

    Directory of Open Access Journals (Sweden)

    LASZLO-ZOLTAN SZTANKOVSZKY

    2015-11-01

    Full Text Available The prescription of drugs is influenced by a number of factors with a great impact upon the health of the main beneficiaries of health services. The purpose of the study is to identify the perception of doctors and pharmacists on drug prescription practices adopted by doctors. Material and Methods: a number of 349 subjects (149 pharmacists and 200 doctors answered a survey about the perception of drug dispensing in Romania. Variables like age, work environment (urban, rural, length of employment were taken into account. Results: When prescribing a treatment, 93% of doctors follow the standard treatment protocol for the given diagnosis and 93,5% of them are declaring that personal resources are the main source for training while the percent appreciated by pharmacists is evaluated to 65,78%. A total of 50% of doctors are considering other criteria than the treatment when prescribing a drug (financial contribution for the patient or National Health Insurance House. A total of 59% of doctors are recommending overthe-counter products while pharmacists consider that is happening in more than 70% of the cases. Conclusions: There are differences of opinion between doctors and pharmacists regarding doctor’s practices of prescribing drugs to their patients, like: kinds of sponsorship for the continuing education, the relationship with the pharmaceutical representative or the frequency of prescribing over-the-counter products or supplements when they are recommending a certain treatment.

  15. A randomized trial of a standard dose of Edmonston-Zagreb measles vaccine given at 4.5 months of age: effect on total hospital admissions.

    Science.gov (United States)

    Martins, Cesario L; Benn, Christine S; Andersen, Andreas; Balé, Carlito; Schaltz-Buchholzer, Frederik; Do, Vu An; Rodrigues, Amabelia; Aaby, Peter; Ravn, Henrik; Whittle, Hilton; Garly, May-Lill

    2014-06-01

    Observational studies and trials from low-income countries indicate that measles vaccine has beneficial nonspecific effects, protecting against non-measles-related mortality. It is not known whether measles vaccine protects against hospital admissions. Between 2003 and 2007, 6417 children who had received the third dose of diphtheria, tetanus, and pertussis vaccine were randomly assigned to receive measles vaccine at 4.5 months or no measles vaccine; all children were offered measles vaccine at 9 months of age. Using hospital admission data from the national pediatric ward in Bissau, Guinea-Bissau, we compared admission rates between enrollment and the 9-month vaccination in Cox models, providing admission hazard rate ratios (HRRs) for measles vaccine versus no measles vaccine. All analyses were conducted stratified by sex and reception of neonatal vitamin A supplementation (NVAS). Before enrollment the 2 groups had similar admission rates. Following enrollment, the measles vaccine group had an admission HRR of 0.70 (95% confidence interval [CI], .52-.95), with a ratio of 0.53 (95% CI, .32-.86) for girls and 0.86 (95% CI, .58-1.26) for boys. For children who had not received NVAS, the admission HRR was 0.53 (95% CI, .34-.84), with an effect of 0.30 (95% CI, .13-.70) for girls and 0.73 (95% CI, .42-1.28) for boys (P = .08, interaction test). The reduction in admissions was separately significant for measles infection (admission HRR, 0 [95% CI, 0-.24]) and respiratory infections (admission HRR, 0.37 [95% CI, .16-.89]). Early measles vaccine may have major benefits for infant morbidity patterns and healthcare costs. Clinical trials registration NCT00168558.

  16. Prescribing smoked cannabis for chronic noncancer pain

    Science.gov (United States)

    Kahan, Meldon; Srivastava, Anita; Spithoff, Sheryl; Bromley, Lisa

    2014-01-01

    Objective To offer preliminary guidance on prescribing smoked cannabis for chronic pain before the release of formal guidelines. Quality of evidence We reviewed the literature on the analgesic effectiveness of smoked cannabis and the harms of medical and recreational cannabis use. We developed recommendations on indications, contraindications, precautions, and dosing of smoked cannabis, and categorized the recommendations based on levels of evidence. Evidence is mostly level II (well conducted observational studies) and III (expert opinion). Main message Smoked cannabis might be indicated for patients with severe neuropathic pain conditions who have not responded to adequate trials of pharmaceutical cannabinoids and standard analgesics (level II evidence). Smoked cannabis is contraindicated in patients who are 25 years of age or younger (level II evidence); who have a current, past, or strong family history of psychosis (level II evidence); who have a current or past cannabis use disorder (level III evidence); who have a current substance use disorder (level III evidence); who have cardiovascular or respiratory disease (level III evidence); or who are pregnant or planning to become pregnant (level II evidence). It should be used with caution in patients who smoke tobacco (level II evidence), who are at increased risk of cardiovascular disease (level III evidence), who have anxiety or mood disorders (level II evidence), or who are taking higher doses of opioids or benzodiazepines (level III evidence). Cannabis users should be advised not to drive for at least 3 to 4 hours after smoking, for at least 6 hours after oral ingestion, and for at least 8 hours if they experience a subjective “high” (level II evidence). The maximum recommended dose is 1 inhalation 4 times per day (approximately 400 mg per day) of dried cannabis containing 9% delta-9-tetrahydrocannabinol (level III evidence). Physicians should avoid referring patients to “cannabinoid” clinics (level

  17. An In Vivo Study of Low-Dose Intra-Articular Tranexamic Acid Application with Prolonged Clamping Drain Method in Total Knee Replacement: Clinical Efficacy and Safety.

    Science.gov (United States)

    Sa-ngasoongsong, Paphon; Chanplakorn, Pongsthorn; Wongsak, Siwadol; Uthadorn, Krisorn; Panpikoon, Tanapong; Jittorntam, Paisan; Aryurachai, Katcharin; Angchaisukisiri, Pantap; Kawinwonggowit, Viroj

    2015-01-01

    Recently, combined intra-articular tranexamic acid (IA-TXA) injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR). However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours). Blood and drainage fluid were collected to measure tranexamic acid (TXA) level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time.

  18. 'It's showed me the skills that he has': pharmacists' and mentors' views on pharmacist supplementary prescribing.

    Science.gov (United States)

    Lloyd, Fran; Parsons, Carole; Hughes, Carmel M

    2010-02-01

    Supplementary prescribing has seen pharmacists assume greater responsibility for prescribing in collaboration with doctors. This study explored the context and experiences, in relation to the practice of supplementary prescribing, of pharmacists and physicians (who acted as their training mentors) at least 12 months after pharmacists had qualified as supplementary prescribers. The setting was primary and secondary healthcare sectors in Northern Ireland. Pharmacists and mentors who had participated in a pre-training study were invited to take part. All pharmacists (n = 47) were invited to participate in focus groups, while mentors (n = 35) were asked to participate in face-to-face semi-structured interviews. The research took place between May 2005 and September 2007. All discussions and interviews were audiotaped, transcribed and analysed using constant comparison. Nine pharmacist focus groups were convened (number per group ranging from three to six; total n = 40) and 31 semi-structured interviews with mentors were conducted. The six main themes that emerged were optimal practice setting, professional progression for prescribing pharmacists, outcomes for prescribing pharmacists, mentors and patients, relationships, barriers to implementation and the future of pharmacist prescribing. Where practised, pharmacist prescribing had been accepted, worked best for chronic disease management, was perceived to have reduced doctors' workload and improved continuity of care for patients. However, three-quarters of pharmacists qualified to practise as supplementary prescribers were not actively prescribing, largely due to logistical and organisational barriers rather than inter-professional tensions. Independent prescribing was seen as contentious by mentors, particularly because of the diagnostic element. Supplementary prescribing has been successful where it has been implemented but a number of barriers remain which are preventing the wider acceptance of this practice

  19. Dental students′ compliance with antibiotic prescribing guidelines for dental infections in children

    Directory of Open Access Journals (Sweden)

    Yee Chen Wong

    2016-01-01

    Full Text Available Context: To investigate the antibiotic prescribing training received by dental students, clinical experience in treating child patients, awareness of antibiotic prescribing guidelines, preparedness in antibiotic prescribing, and compliance with antibiotic prescribing guidelines for the management of dental infections in children. Methods: This was a cross-sectional study involving final year dentals students from Malaysian and Asian dental schools. A self-administered questionnaire consisting of five clinical case scenarios was e-mailed to all final year students at selected dental schools. Students′ responses were compared for each clinical case scenario with the prescribing guidelines of the American Academy of Pediatric Dentistry and the American Dental Association. Compliance in each scenario was tested for association with their preparedness in antibiotic prescribing, previous training on antibiotic prescribing and awareness of antibiotic prescribing guidelines using Chi-square test. Data collected were analyzed using SPSS statistics version 20. Results: A total of 108 completed responses were received. About 74 (69% students were from Malaysian dental schools. The compliance rate with prescribing guidelines ranged from 15.7% to 43.5%. Those attending Malaysian dental schools (47.3% and those who had treated child patient more often (46.3% were more likely (P < 0.05 to be aware of the guidelines. Those who had received antibiotic prescribing training (21.3% were more likely to think they were well prepared in antibiotic prescribing (P < 0.05. Conclusions: Final year dental students had low awareness and compliance with antibiotic prescribing guidelines. Further research is needed to investigate how compliance with the guidelines may be enhanced.

  20. The impact of a closed-loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before-and-after study.

    Science.gov (United States)

    Franklin, Bryony Dean; O'Grady, Kara; Donyai, Parastou; Jacklin, Ann; Barber, Nick

    2007-08-01

    To assess the impact of a closed-loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Before-and-after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Closed-loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Prescribing errors were identified in 3.8% of 2450 medication orders pre-intervention and 2.0% of 2353 orders afterwards (pMedical staff required 15 s to prescribe a regular inpatient drug pre-intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre-intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; chi(2) test). A closed-loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication-related tasks increased.

  1. The impact of a closed‐loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before‐and‐after study

    Science.gov (United States)

    Franklin, Bryony Dean; O'Grady, Kara; Donyai, Parastou; Jacklin, Ann; Barber, Nick

    2007-01-01

    Objectives To assess the impact of a closed‐loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Design, setting and participants Before‐and‐after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Intervention Closed‐loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Main outcome measures Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Results Prescribing errors were identified in 3.8% of 2450 medication orders pre‐intervention and 2.0% of 2353 orders afterwards (pMedical staff required 15 s to prescribe a regular inpatient drug pre‐intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre‐intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; χ2 test). Conclusions A closed‐loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication‐related tasks increased. PMID:17693676

  2. Prevalence and Predictors of Inappropriate Medications Prescribing ...

    African Journals Online (AJOL)

    Data analysis involved use of World Health Organization (WHO) prescribing indicators, Updated 2002 Beer's criteria and DRUG-REAX® system software package of MICROMEDEX (R) Healthcare Series to assess the prescribing pattern, identify potentially inappropriate medications and potential drug-drug interactions, ...

  3. Psychiatric Prescribers' Experiences With Doctor Shoppers.

    Science.gov (United States)

    Worley, Julie; Johnson, Mary; Karnik, Niranjan

    2015-01-01

    Doctor shopping is a primary method of prescription medication diversion. After opioids, benzodiazepines and stimulants are the next most common prescription medications used nonmedically. Studies have shown that patients who engage in doctor shopping find it fun, exciting, and easy to do. There is a lack of research on the prescriber's perspective on the phenomenon of doctor shopping. This study investigates the experiences of prescribers in psychiatry with patients who engage in doctor shopping. Fifteen prescribers including psychiatrists and psychiatric nurse practitioners working in outpatient psychiatry were interviewed to elicit detailed information about their experiences with patients who engage in doctor shopping. Themes found throughout the interview were that psychiatric prescribers' experience with patients who engage in doctor shopping includes (a) detecting red flags, (b) negative emotional responding, (c) addressing the patient and the problem, and (d) inconsistently implementing precautions. When red flags were detected when prescribing controlled drugs, prescribers in psychiatry experienced both their own negative emotional responses such as disappointment and resentment as well as the negative emotions of the patients such as anger and other extreme emotional responses. Psychiatric prescribers responded to patient's doctor shopping in a variety of ways such as changing their practice, discharging the patients or taking steps to not accept certain patients identified as being at risk for doctor shopping, as well as by talking to the patient and trying to offer them help. Despite experiencing doctor shopping, the prescribers inconsistently implemented precautionary measures such as checking prescription drug monitoring programs. © The Author(s) 2015.

  4. Concordance with prescribing information dosage recommendations for dipeptidyl-peptidase-4 inhibitors among type 2 diabetes mellitus patients with moderate to severe chronic kidney disease.

    Science.gov (United States)

    Huang, Huan; Shetty, Sharash; Bauer, Elise; Lang, Kathleen

    2018-06-01

    To estimate the proportion of patients with moderate to severe chronic kidney disease (CKD) whose initial dipeptidyl-peptidase-4 inhibitor (DPP4-i) dosage was concordant with prescribing information (label) recommendations in the United States. Adult patients with type 2 diabetes mellitus (T2DM) who initiated a DPP4-i (linagliptin, sitagliptin, saxagliptin) between 1 January 2011 and 30 June 2014 were identified using electronic medical records and administrative claims, with index date being the date of first observed DPP4-i treatment. Patients were required to have chronic kidney disease (CKD) stage 3b, 4 or 5 (estimated Glomerular Filtration Rate [eGFR] value <45 ml/min/1.73 m 2 ) during the 12 month pre-index period. Patients were classified as concordant or not concordant based on whether the first prescribed dose was consistent with label recommendations. Demographics, clinical characteristics, resource use and costs during pre-index were evaluated by DPP4-i concordance status. Of the 492 patients (323 sitagliptin, 57 saxagliptin, 112 linagliptin), 36.2% were prescribed doses that were not concordant with label recommendations (44.9% for sitagliptin, 57.9% for saxagliptin and 0% for linagliptin [which does not require dosage adjustment]). Concordant patients were slightly older (mean age 71 years vs. 68, p = .01) but had similar gender distribution (55% vs. 60% female, p = .31) compared to those who were not concordant. They had lower general health status (Charlson Comorbidity Score 2.6 vs. 2.2, p = .03), and had similar pre-index all-cause total costs ($25,245 vs. $21,972, p = .68) and lower pre-index T2DM-related costs ($1618 vs. $1922, p = .05). More than a third of DPP4-i patients with CKD stage 3b or higher were prescribed doses not concordant with DPP4-i label dosage recommendations.

  5. [Reasons for inappropriate prescribing of antibiotics in a high-complexity pediatric hospital].

    Science.gov (United States)

    Ruvinsky, Silvina; Mónaco, Andrea; Pérez, Guadalupe; Taicz, Moira; Inda, Laura; Kijko, Ivana; Constanzo, Patricia; Bologna, Rosa

    2011-12-01

    Determine the reasons for inappropriate prescription of antibiotics and identify opportunities to improve prescription of these drugs in pediatric patients hospitalized in intermediate and intensive care units. A prospective, descriptive longitudinal study was conducted of pediatric patients in intermediate and intensive care units who received parenteral administration of antibiotics, with the exception of newborns, burn unit patients, and surgical prophylaxis patients. A univariate analysis and multiple logistic regression were performed. A total of 376 patients with a median of age of 50 months were studied (interquartile range [IQR] 14.5-127 months). Out of the total patients studied, 75% had one or more underlying conditions. A total of 40.6% of these patients had an oncologic pathology and 33.5% had neurological conditions. The remaining 25.9% had other underlying conditions. Antibiotic treatment was inappropriate in 35.6% of the patients studied (N = 134). In 73 (54.4%) of the 134 cases, inappropriate use was due to the type of antibiotic prescribed, the dose administered, or the treatment period. The 61 (45.5%) remaining cases did not require antibiotic treatment. In the multivariate analysis, the risk factors for inappropriate use of antibiotics were: administration of ceftriaxone OR 2 (95% CI, 1.3-3.7; P = 0.02); acute lower respiratory tract infection OR 1.8 (95% CI, 1.1-3.3; P < 0.04); onset of fever of unknown origin in hospital inpatients OR 5.55 (95% CI, 2.5-12; P < 0.0001); and febrile neutropenia OR 0.3 (95% CI, 0.1-0.7; P = 0.009). Inappropriate use of antibiotics was less common in the clinical conditions that were well-characterized. Prescribing practices that could be improved were identified through the preparation and circulation of guidelines for antibiotic use in hospital inpatients.

  6. Influences on the prescribing of new drugs.

    Science.gov (United States)

    Tobin, Luke; de Almedia Neto, Abelio C; Wutzke, Sonia; Patterson, Craig; Mackson, Judith; Weekes, Lynn; Williamson, Margaret

    2008-01-01

    The aim of this study was to identify the factors that influence prescribing of new drugs among general practitioners, endocrinologists and psychiatrists. Four focus groups were conducted with GPs, endocrinologists and psychiatrists on sources of awareness and influences on prescribing of new drugs. Pharmaceutical companies were the most important source for becoming aware of new drugs. There were many influences on the decision to prescribe a new drug, the most important being efficacy, safety, cost and advantage over existing therapies. Endocrinologists placed greater emphasis on evidence from clinical trials and scientific conferences, and psychiatrists and GPs placed more weight on pharmaceutical representatives, colleagues and specialists. New drug prescribing occurs in a complex environment with many influences. Effective interventions to promote rational, safe and effective prescribing of new drugs will need to be cognisant of these factors.

  7. Tolerance of the human spinal cord to single dose radiosurgery

    International Nuclear Information System (INIS)

    Ryu, S.; Zhu, G.; Yin, F.-F.; Ajlouni, M.; Kim, J.H.

    2003-01-01

    Tolerance of the spinal cord to the single dose of radiation is not well defined. Although there are cases of human spinal cord tolerance from re-irradiation to the same cord level, the information about the tolerance of human spinal cord to single large dose of radiosurgery is not available. We carried out spinal radiosurgery to treat spinal metastasis and studied the single dose tolerance of the human spinal cord in an ongoing dose escalation paradigm. A total of 39 patients with 48 lesions of spinal metastasis were treated with single dose radiosurgery at Henry Ford Hospital. The radiosurgery dose was escalated from 8 Gy to 16 Gy at 2 Gy increment. The radiation dose was prescribed to periphery of the spinal tumor. The radiation dose to the spinal cord was estimated by computerized dosimetry. The median follow-up time was 10 months (range 6-18 months) from the radiosurgery. The endpoint of the study was to demonstrate the efficacy of the spinal radiosurgery and to determine the tolerance of human spinal cord to single dose radiosurgery. The dose to the spinal cord was generally less than 50 % of the prescribed radiation dose. The volume of the spinal cord that received higher than this dose was less than 20 % of the anterior portion of the spinal cord. Maximum single dose of 8 Gy was delivered to the anterior 20 % of the spinal cord in this dose escalation study. The dose volume histogram will be presented. There was no acute or subacute radiation toxicity detected clinically and radiologically during the maximum follow-up of 20 months. Further dose escalation is in progress. The single tolerance dose of the human spinal cord appears to be at least 8 Gy when it was given to the 20 % of the cord volume, although the duration of follow up is not long enough to detect severe late cord toxicity. This study offers a valuable radiobiological basis of the normal spinal cord tolerance, and opens spinal radiosurgery as a safe treatment for spinal metastasis

  8. Impact of pharmacists assisting with prescribing and undertaking medication review on oxycodone prescribing and supply for patients discharged from surgical wards.

    Science.gov (United States)

    Tran, T; Taylor, S E; Hardidge, A; Findakly, D; Aminian, P; Elliott, R A

    2017-10-01

    Overprescribing of oxycodone is a contributor to the epidemic of prescription opioid misuse and deaths. Practice models to optimize oxycodone prescribing and supply need to be evaluated. We explored the impact of pharmacist-assisted discharge prescribing and medication review on oxycodone prescribing and supply for patients discharged from surgical wards. A retrospective audit was conducted on two surgical inpatient wards following a 16-week prospective pre- and post-intervention study. During the pre-intervention period, discharge prescriptions were prepared by hospital doctors and then reviewed by a ward pharmacist (WP) before being dispensed. Post-intervention, prescriptions were prepared by a project pharmacist in consultation with hospital doctors and then reviewed by a WP and dispensed. Proportion of patients who were prescribed, and proportion supplied, oxycodone on discharge; Median amount (milligrams) of oxycodone prescribed and supplied, for patients who were prescribed and supplied at least one oxycodone-containing preparation, respectively. A total of 320 and 341 patients were evaluated pre- and post-intervention, respectively. Pre-intervention, 75.6% of patients were prescribed oxycodone; after WP review, 60.3% were supplied oxycodone (Psupplied was 100 milligrams/patient. Post-intervention, 68.6% of patients were prescribed oxycodone; after WP review, 57.8% were supplied oxycodone (Psupplied was 50 milligrams/patient (difference in amount prescribed and supplied: 50 milligrams, Psupplied oxycodone but not the amount supplied/patient. Having a pharmacist assist with prescribing reduced the amount of oxycodone supplied. © 2017 John Wiley & Sons Ltd.

  9. Antibiotic prescribing and patient satisfaction in primary care in England: cross-sectional analysis of national patient survey data and prescribing data.

    Science.gov (United States)

    Ashworth, Mark; White, Patrick; Jongsma, Hannah; Schofield, Peter; Armstrong, David

    2016-01-01

    Concerns about adverse effects on patient satisfaction may be an important obstacle to attempts to curtail antibiotic prescribing. To determine the relationship between antibiotic prescribing in general practice and reported patient satisfaction. Retrospective cross-sectional study of general practices in England. Data were obtained from the General Practice Patient Survey (GPPS) in 2012 (2.7 million questionnaires in England; 982 999 responses; response rate 36%); the national Quality and Outcomes Framework dataset for England, 2011-2012 (8164 general practices); and general practice and demographic characteristics. Standardised measures of antibiotic prescribing volumes were obtained for each practice in England during 2012-2013, together with 12 other nationally available prescribing variables. The role of antibiotic prescribing volume was identified as a determinant of GPPS scores and adjusted for demographic and practice factors using multiple linear regression. The final dataset consisted of 7800 (95.5%) practices. A total of 33.7 million antibiotic prescriptions were issued to a registered population of 53.8 million patients. Antibiotic prescribing volume was a significant positive predictor of all 'doctor satisfaction' and 'practice satisfaction' scores in the GPPS, and was the strongest predictor of overall satisfaction out of 13 prescribing variables. A theoretical 25% reduction in antibiotic prescribing volume would be associated with 0.5-1.0% lower patient satisfaction scores, a drop of 3-6 centile points in national satisfaction ranking. Patients were less satisfied in practices with frugal antibiotic prescribing. A cautious approach to antibiotic prescribing may require a trade-off in terms of patient satisfaction. © British Journal of General Practice 2016.

  10. [Clinical applications of dosing algorithm in the predication of warfarin maintenance dose].

    Science.gov (United States)

    Huang, Sheng-wen; Xiang, Dao-kang; An, Bang-quan; Li, Gui-fang; Huang, Ling; Wu, Hai-li

    2011-12-27

    To evaluate the feasibility of clinical application for genetic based dosing algorithm in the predication of warfarin maintenance dose in Chinese population. The clinical data were collected and blood samples harvested from a total of 126 patients undergoing heart valve replacement. The genotypes of VKORC1 and CYP2C9 were determined by melting curve analysis after PCR. They were divided randomly into the study and control groups. In the study group, the first three doses of warfarin were prescribed according to the predicted warfarin maintenance dose while warfarin was initiated at 2.5 mg/d in the control group. The warfarin doses were adjusted according to the measured international normalized ratio (INR) values. And all subjects were followed for 50 days after an initiation of warfarin therapy. At the end of a 50-day follow-up period, the proportions of the patients on a stable dose were 82.4% (42/51) and 62.5% (30/48) for the study and control groups respectively. The mean durations of reaching a stable dose of warfarin were (27.5 ± 1.8) and (34.7 ± 1.8) days and the median durations were (24.0 ± 1.7) and (33.0 ± 4.5) days in the study and control groups respectively. Significant differences existed in the durations of reaching a stable dose between the two groups (P = 0.012). Compared with the control group, the hazard ratio (HR) for the duration of reaching a stable dose was 1.786 in the study group (95%CI 1.088 - 2.875, P = 0.026). The predicted dosing algorithm incorporating genetic and non-genetic factors may shorten the duration of achieving efficiently a stable dose of warfarin. And the present study validates the feasibility of its clinical application.

  11. Impact of Internally Developed Electronic Prescription on Prescribing Errors at Discharge from the Emergency Department.

    Science.gov (United States)

    Hitti, Eveline; Tamim, Hani; Bakhti, Rinad; Zebian, Dina; Mufarrij, Afif

    2017-08-01

    Medication errors are common, with studies reporting at least one error per patient encounter. At hospital discharge, medication errors vary from 15%-38%. However, studies assessing the effect of an internally developed electronic (E)-prescription system at discharge from an emergency department (ED) are comparatively minimal. Additionally, commercially available electronic solutions are cost-prohibitive in many resource-limited settings. We assessed the impact of introducing an internally developed, low-cost E-prescription system, with a list of commonly prescribed medications, on prescription error rates at discharge from the ED, compared to handwritten prescriptions. We conducted a pre- and post-intervention study comparing error rates in a randomly selected sample of discharge prescriptions (handwritten versus electronic) five months pre and four months post the introduction of the E-prescription. The internally developed, E-prescription system included a list of 166 commonly prescribed medications with the generic name, strength, dose, frequency and duration. We included a total of 2,883 prescriptions in this study: 1,475 in the pre-intervention phase were handwritten (HW) and 1,408 in the post-intervention phase were electronic. We calculated rates of 14 different errors and compared them between the pre- and post-intervention period. Overall, E-prescriptions included fewer prescription errors as compared to HW-prescriptions. Specifically, E-prescriptions reduced missing dose (11.3% to 4.3%, p prescriptions, however, were associated with a significant increase in duplication errors, specifically with home medication (1.7% to 3%, p=0.02). A basic, internally developed E-prescription system, featuring commonly used medications, effectively reduced medication errors in a low-resource setting where the costs of sophisticated commercial electronic solutions are prohibitive.

  12. Drug Use Evaluation of Three Widely Prescribed Antibiotics in a

    Directory of Open Access Journals (Sweden)

    Mehdi Mohammadi

    2015-10-01

    Full Text Available Background: Drug utilization studies are helpful in understanding the current practice. We have conducted a retrospective study to evaluate the relevant use of a group of most commonly prescribed antibiotics in a teaching hospital in Iran.  The results of this study may be of help for clinicians to improve the patient care.Methods: Patients who received parenteral ceftazidim, vancomycin and amikacin from December2010 to May 2011 were enrolled in this study. Patient’s data including demographic, length of Hospital stay, drug allergy, first and final diagnosis were recorded in a predesigned data collection form. American Hospital Formulary Services (AHFS book were used as a reference for evaluation of study drug indication and dosing according to diagnosis and microbiological culture. Defined Daily Dose (DDD of each drug extracted from Anatomic and Therapeutic Chemical classification system (ATC/DDD and drug usage data evaluated by calculating the ratio of prescribed drug to its DDD.Results: The ratio of prescribed daily dose to DDD was 0.78, 0.95 and 0.86 for amikacin, ceftazidime and vancomycin respectively. Between amikacin group, 43 patients (86% received drug empirically, the number of empiric treatments for ceftazidim and vancomycin were 45(90% and 44 patients (88%. The renal function tests (Blood Urea Nitrogen, Serum Creatinin were evaluated in 56% of amikacin group, 64% in ceftazidime group and 78% in vancomycin group.Conclusion: The results of this study indicate the need to establish continuing medical education (CME courses for physicians to familiarize them with standards required to use and monitor these agents.

  13. Tacrolimus and mycophenolate mofetil after nonmyeloablative matched-sibling donor allogeneic stem-cell transplantations conditioned with fludarabine and low-dose total body irradiation.

    Science.gov (United States)

    Nieto, Yago; Patton, Nigel; Hawkins, Timothy; Spearing, Ruth; Bearman, Scott I; Jones, Roy B; Shpall, Elizabeth J; Rabinovitch, Rachel; Zeng, Chan; Barón, Anna; McSweeney, Peter A

    2006-02-01

    We evaluated tacrolimus/mycophenolate mofetil (MMF) for graft-versus-host disease (GVHD) prophylaxis after a nonmyeloablative stem cell transplantation (NST) from a matched sibling donor (MSD). Thirty-two patients (median age, 57 years) with advanced hematologic malignancies, who were poor candidates for a conventional myeloablative transplantation, received fludarabine (30 mg/m(2), day -4 to day -2), total-body irradiation (TBI) (200 cGy, day 0), infusion of donor peripheral blood progenitor cells (day 0), oral tacrolimus 0.06 mg/kg twice daily (from day 3), and oral MMF at 15 mg/kg twice daily (days 0-+27). Tacrolimus was tapered from day +100 to day +180 in those patients with indolent malignancies (n = 25), and from day +35 to day +56 in those with aggressive tumors (n = 7). Regimen toxicities and myelosuppression were mild, allowing 75% of patients to have entirely outpatient transplantations. One patient (3%) experienced a nonfatal graft rejection. Rates of grades II-IV and III-IV acute GVHD were 15.6% and 3%, respectively. Acute GVHD was diagnosed at median day +78 (range, days +31-+84). Extensive chronic GVHD was observed in 10 of 24 evaluable patients (41.6%) at a median onset of day +198 (range, days +128-+277), either spontaneously (n = 5) or elicited after tumor progression (n = 5). Five patients experienced transplantation-related mortality (TRM) (15.6%) from either acute GVHD-related multiorgan failure (MOF) (n = 3) or infectious complications (n = 2). At median follow-up of 19 months (range, 2-41 months), the overall survival, progression-free survival, and disease-free survival rates are 62.5%, 50%, and 40%, respectively. In conclusion, the use of tacrolimus/MMF after MSD NST is associated with encouraging rates of GVHD control.

  14. Methodology for obtaining a solution for the three-dimensional Boltzmann transport equation and an expression for the calculation of the total doses considering Compton scattering simulated by Klein-Nishina

    International Nuclear Information System (INIS)

    Rodriguez, Barbara A.; Borges, Volnei; Vilhena, Marco Tullio

    2005-01-01

    In this work we would like to obtain a formulation of an analytic method for the solution of the three dimensional transport equation considering Compton scattering and an expression for total doses due to gamma radiation, where the deposited energy by the free electron will be considered. For that, we will work with two equations: the first one for the photon transport, considering the Klein-Nishina kernel and energy multigroup model, and the second one considering the free electron with the screened Rutherford scattering. (author)

  15. Comparison of equations for dosing of medications in renal impairment.

    Science.gov (United States)

    Khanal, Aarati; Peterson, Gregory M; Jose, Matthew D; Castelino, Ronald L

    2017-06-01

    The aim of this study is to determine the concordance among the Cockcroft-Gault, the Modification of Diet in Renal Disease and the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations in hypothetical dosing of renally cleared medications. A total of 2163 patients prescribed at least one of the 31 renally cleared drugs under review were included in the study. Kidney function was estimated using the three equations. We compared actual prescribed dosages of the same drug with recommended dosages based on the kidney function as calculated by each of the equations and applying dosing recommendations in the Australian Medicines Handbook. There was a significant difference in the kidney function values estimated from the three equations (P < 0.001). Despite the good overall agreement in renal drug dosing, we found selected but potentially important discrepancies among the doses rendered from the equations. The CKD-EPI equation non-normalized for body surface area had a greater rate of concordance with the Cockcroft-Gault equation than the Modification of Diet in Renal Disease equation for renal drug dosing. There is need for a long-term multi-centre study in a diverse population to define the clinical effects of the discrepancies among the equations for drug dosing. Given the greater concordance of the non-normalized CKD-EPI equation with the Cockcroft-Gault equation for dosing, the recommendation by Kidney Health Australia and the United States National Kidney Disease Education Program that 'dosing based on either eCrCl or an eGFR with body surface area normalization removed are acceptable' seems suitable and practicable for the purpose of dosing of non-critical drugs in the primary care setting. © 2016 Asian Pacific Society of Nephrology.

  16. What do providers want to know about opioid prescribing? A qualitative analysis of their questions.

    Science.gov (United States)

    Cushman, Phoebe A; Liebschutz, Jane M; Hodgkin, Joseph G; Shanahan, Christopher W; White, Julie L; Hardesty, Ilana; Alford, Daniel P

    2017-01-01

    In 2012, the US Food and Drug Administration (FDA) responded to the opioid crisis with a Risk Evaluation and Mitigation Strategy, requiring manufacturers of extended-release/long-acting opioids to fund continuing medical education based on the "FDA Blueprint for Prescriber Education." Topics in the Blueprint are "Assessing Patients for Treatment," "Initiating Therapy, Modifying Dosing, and Discontinuing Use," "Managing Therapy," "Counseling Patients and Caregivers about Safe Use," "General Drug Information," and "Specific Drug Information." Based on the FDA Blueprint, Boston University School of Medicine's "Safe and Competent Opioid Prescribing Education" (SCOPE of Pain) offers live trainings for physicians and other prescribers. During trainings, participants submit written questions about the curriculum and/or their clinical experiences. The objective was to compare themes that arose from questions asked by SCOPE of Pain participants with content of the FDA Blueprint in order to evaluate how well the Blueprint answers prescribers' concerns. The authors conducted qualitative analyses of all 1309 questions submitted by participants in 29 trainings across 16 states from May 2013 to May 2015, using conventional content analysis to code the questions. Themes that emerged from participants' questions were then compared with the Blueprint. Most themes fell into the topic categories of the Blueprint. Five main themes diverged: Participants sought information on (1) safe alternatives to opioids, (2) overcoming barriers to safe opioid prescribing, (3) government regulations of opioid prescribing, (4) the role of marijuana in opioid prescribing, and (5) maintaining a positive provider-patient relationship while prescribing opioids. In addition to learning the mechanics of safe opioid prescribing, providers want to understand government regulations and effective patient communication skills. Aware of the limitations of opioids in managing chronic pain, providers seek advice

  17. Neuropharmacology and mental health nurse prescribers.

    Science.gov (United States)

    Skingsley, David; Bradley, Eleanor J; Nolan, Peter

    2006-08-01

    To outline the development and content of a 'top-up' neuropharmacology module for mental health nurse prescribers and consider how much pharmacology training is required to ensure effective mental health prescribing practice. Debate about the content of prescribing training courses has persisted within the United Kingdom since the mid-1980s. In early 2003 supplementary prescribing was introduced and gave mental health nurses the opportunity to become prescribers. The challenge of the nurse prescribing curriculum for universities is that they have only a short time to provide nurses from a range of backgrounds with enough knowledge to ensure that they meet agreed levels of competency for safe prescribing. There is growing concern within mental health care that the prescribing of medication in mental health services falls short of what would be deemed good practice. Over the past two decades, nurse training has increasingly adopted a psychosocial approach to nursing care raising concerns that, although nurses attending prescribing training may be able to communicate effectively with service users, they may lack the basic knowledge of biology and pharmacology to make effective decisions about medication. Following the completion of a general nurse prescribing course, mental health nurses who attended were asked to identify their specific needs during the evaluation phase. Although they had covered basic pharmacological principles in their training, they stated that they needed more specific information about drugs used in mental health; particularly how to select appropriate drug treatments for mental health conditions. This paper describes how the nurses were involved in the design of a specific module which would enable them to transfer their theoretical leaning to practice and in so doing increase their confidence in their new roles. The findings of this study suggest that the understanding and confidence of mental health nurse prescribers about the drugs they

  18. Psychotropic prescribing in seriously violent men with schizophrenia or personality disorder in a UK high security hospital.

    Science.gov (United States)

    Stone-Brown, Keir; Naji, Mahmood; Francioni, Alex; Myers, Kyle; Samarendra, Harsh; Mushtaq-Chaudhry, Haseeb; Heslop, Stephen; Sengupta, Samrat; Ross, Callum C; Larkin, Fintan; Das, Mrigendra

    2016-02-01

    To analyze antipsychotic prescribing patterns in a UK high security hospital (HSH) that treats seriously violent men with either schizophrenia or personality disorder and examine how different groups consented to treatment and prescribing for metabolic conditions. We hypothesized that there would be high prevalence of antipsychotic polypharmacy, and high-dose antipsychotic and clozapine prescribing. HSHs treat seriously violent, mentally disordered offenders, and the extant literature on prescribing patterns in forensic settings is sparse. Prescribing and clinical data on all 189 patients in a UK HSH were collected from the hospital's databases. Data were analyzed using SPSS. The population was split into the following groups: schizophrenia spectrum disorder (SSD-only), personality disorder (PD-only), and comorbid schizophrenia spectrum disorder and PD. The majority (93.7%) of all patients were prescribed at least one antipsychotic, and (27.5%) were on clozapine. Polypharmacy was prevalent in 22.2% and high-dose antipsychotic in 27.5%. Patients on clozapine were more likely to be prescribed antidiabetic, statins, or antihypertensive medication. Patients in the PD-only group were more likely to be deemed to have the capacity to consent to treatment and be prescribed clozapine in contrast to the SSD-only group. Rates of clozapine and high-dose antipsychotic prescribing were higher than in other psychiatric settings, while polypharmacy prescribing rates were lower. Higher clozapine prescribing rates may be a function of a treatment-resistant and aggressive population. A higher proportion of PD-only patients consented to treatment and received clozapine compared with in-house SSD-only as well as other psychiatric settings. Implications of the findings are discussed.

  19. Antibiotic prescribing in dental practice in Belgium.

    Science.gov (United States)

    Mainjot, A; D'Hoore, W; Vanheusden, A; Van Nieuwenhuysen, J-P

    2009-12-01

    To assess the types and frequency of antibiotic prescriptions by Belgian dentists, the indications for antibiotic prescription, and dentists' knowledge about recommended practice in antibiotic use. In this cross-sectional survey, dental practitioners were asked to record information about all antibiotics prescribed to their patients during a 2-week period. The dental practitioners were also asked to complete a self-administered questionnaire regarding demographic data, prescribing practices, and knowledge about antibiotic use. A random sample of 268 Belgian dentists participated in the survey. During the 2-week period, 24 421 patient encounters were recorded; 1033 patients were prescribed an antibiotic (4.2%). The median number of prescriptions per dentist for the 2 weeks was 3. Broad spectrum antibiotics were most commonly prescribed: 82% of all prescriptions were for amoxycillin, amoxycillin-clavulanic acid and clindamycin. Antibiotics were often prescribed in the absence of fever (92.2%) and without any local treatment (54.2%). The most frequent diagnosis for which antibiotics were prescribed was periapical abscess (51.9%). Antibiotics were prescribed to 63.3% of patients with periapical abscess and 4.3% of patients with pulpitis. Patterns of prescriptions were confirmed by the data from the self-reported practice. Discrepancies between observed and recommended practice support the need for educational initiatives to promote rational use of antibiotics in dentistry in Belgium.

  20. Drug formularies--good or evil? A view using prescribing analyses and cost trends data.

    Science.gov (United States)

    Chapman, S

    1994-01-01

    In the UK, the drugs bill has almost trebled in the last 10 years and is consuming an increasing proportion of the total National Health Service spend. If the drugs bill can be limited, greater funds will be available for other areas of the health service. Therefore, cost containment measures which include prescribing from a formulary or generic prescribing are now widely encouraged. Prescribing analyses and cost trends data generated from pharmacists sending dispensed general practitioners' prescriptions to a central point for reimbursement are a valuable tool in the assessment of prescribing habits and can be used by general practitioners when preparing a formulary. In the West Midlands, such data have been used to identify areas of growth in cardiovascular drugs and problem areas where prescribing an expensive formulation has led to a dramatic increase in costs.

  1. Nurse practitioner prescribing: an international perspective

    Directory of Open Access Journals (Sweden)

    Fong J

    2015-10-01

    Full Text Available Jacqueline Fong,1,2 Thomas Buckley,2 Andrew Cashin3 1St George Hospital, Kogarah, 2Sydney Nursing School, University of Sydney, Camperdown, NSW, Australia; 3School of Health and Human Sciences, Southern Cross University, Lismore, NSW, Australia Background: Internationally, the delivery of care provided by nurses and midwives has undergone a significant change due to a variety of interrelated factors, including economic circumstances, a diminishing number of medical providers, the unavailability of adequate health care services in underserved and rural areas, and growing specialization among the professions. One solution to the challenges of care delivery has been the introduction of nurse practitioners (NPs and the authorization of NPs to prescribe medicines. Aim: The aim of this paper was to review the current international literature related to NP prescribing and compare the findings to the Australian context. The review focuses on literature from the United States, Canada, Europe, Australia, and New Zealand. Methods: Databases were searched from January 2000 to January 2015. The following keywords: “nurse practitioner”, “advanced nurse”, “advanced practice nurse”, “prescri*”, “Australia”, “United States America”, “UK”, “New Zealand”, “Canada”, “Europe”, “drug prescri*”, “prescri* authority”, and “prescri* legislation” were used. Findings: NPs tend to prescribe in differing contexts of practice to provide care in underserved populations and require good systems literacy to practice across complex systems. The key themes identified internationally related to NP prescribing relate to barriers to prescribing, confidence in prescribing, and the unique role of NPs in prescribing medicines, eg, the high prevalence of prescribing pain medicines in several countries, including Australia. Conclusion: Across all countries reviewed, there appears a need for further research into the organizational and

  2. Review on patients radiation dose and frequency of procedures during medical exposure in Sudan

    International Nuclear Information System (INIS)

    Abu Baker, Samah Mohamed Nasr

    2015-09-01

    The aim of this study was to estimate patient dose, the annual frequency and the number of staff and devices in the medical applications of ionizing radiation in Sudan. Survey was conducted on diagnostic radiology, nuclear medicine and radiotherapy. With respect to diagnostic radiology, only patient radiation dose was estimated. The data for diagnostic radiology was obtained from 24 peer reviewed scientific published literatures during the years ( 2006 - 2015). The collected publications included about 64 Sudanese hospitals covering different types of diagnostic exams. A values of the effective dose for pediatrics and adult patients were within the ranges of similar worldwide values published by UNSCEAR report in 2008 with exceptional to fluoroscopy hysterosalpingography for adult patients. For nuclear medicine procedures, questionnaires were distributed to five hospitals representing the whole existing NM department in Sudan at the time of of study. The estimated total annual frequency of diagnostic procedures was 0.2 per 1000 population. The estimated total annual collective and annual per caput effective dose from all NM procedures were 16.268 man Sv and 0.5 μSv, respectively. Comparing the annual per caput effective dose with UNSCEAR value our results was less than the worldwide value and greater than the value for heath care level 111-1 v countries. Questionnaires were also distributed to collect data on radiotherapy procedures performed in the two existing radioisotopes Sudanese hospitals. The prescribed dose and the number of fractions were comparable between the two hospitals. The minimum prescribed dose was 20 Gy with 5 fractions for nasopharynx (NPH) palliative and the maximum prescribed dose was 64 Gy with 32 fractions for prostate.(Author)

  3. Primary care hypnotic and anxiolytic prescription: Reviewing prescribing practice over 8 years

    Directory of Open Access Journals (Sweden)

    Lloyd D Hughes

    2016-01-01

    Full Text Available Introduction: Over the last few years, hypnotic and anxiolytic medications have had their clinical efficacy questioned in the context of concerns regarding dependence, tolerance alongside other adverse effects. It remains unclear how these concerns have impacted clinical prescribing practice. Materials and Methods: This is a study reviewing community-dispensed prescribing data for patients on the East Practice Medical Center list in Arbroath, Scotland, in 2007, 2011 and 2015. Anxiolytic and hypnotic medications were defined in accordance with the British National Formulary chapter 4.1.1 and chapter 4.1.2. All patients receiving a drug within this class in any of the study years were collated and anonymized using primary care prescribing data. The patients′ age, gender, name of the prescribed drug(s, and total number of prescriptions in this class over the year were extracted. Results: The proportion of patients prescribed a benzodiazepine medication decreased between 2007 and 2015: 83.8% (n = 109 in 2007, 70.5% (n = 122 in 2011, and 51.7% (n = 138 in 2015 (P = 0.006. The proportion of these patients prescribed a nonbenzodiazepine drug increased between 2007 and 2015: 30% (n = 39 in 2007, 46.2% (n = 80 in 2011, and 52.4% (n = 140 in 2015 (P = 0.001. There was a significant increase in the number of patients prescribed melatonin (P = 0.020. Discussion: This study reports a reduction in benzodiazepine prescriptions in primary care alongside increases in nonbenzodiazepine and melatonin prescribing, with an increase in prescribing rates of this drug class overall. Conclusion: Changes in this prescribing practice may reflect the medicalization of insomnia, local changes in prescribing practice and alongside national recommendations.

  4. Low-dose total body irradiation and G-CSF without hematopoietic stem cell support in the treatment of relapsed or refractory acute myelogenous leukemia (AML), or AML in second or subsequent remission

    International Nuclear Information System (INIS)

    Shulman, Lawrence N.; Tarbell, Nancy J.; Storen, Elizabeth; Marcus, Karen; Mauch, Peter M.

    1998-01-01

    Purpose: Patients with relapsed acute myelogenous leukemia (AML), who are not eligible for bone marrow transplantation, have a poor prognosis when treated with chemotherapy alone. Total body irradiation (TBI) is an effective modality against AML when used in doses of 1000-1400 cGy with hematopoietic stem cell support. We undertook a phase I study of TBI with granulocyte-colony-stimulating factor (G-CSF) support, without stem cell support in patients with AML either in relapse or second or subsequent remission. Methods and Materials: Patients with relapsed AML, or AML in second or subsequent remission were treated in a phase I study of TBI followed by G-CSF. The first dose level was 200 cGy. After the initial cohort of patients it was clear that patients with overt leukemia did not benefit from this treatment, and subsequent patients were required to be in remission at the time of TBI. Results: Eleven patients were treated, 4 in overt relapse, and 7 in remission. 200 cGy was used in all, and dose escalation was not possible due to prolonged thrombocytopenia in all patients but one. Neutrophil recovery was adequate in those patients who remained in remission after TBI. Patients with overt leukemia had transient reduction in blast counts, but rapid recurrence of their leukemia. Patients treated in remission had short remissions, with the exception of one patient who is in remission 32 months after treatment. Conclusion: There is some antileukemic effect of TBI even at 200 cGy, though this dose appears to be too low to help a significant number of patients. If TBI is to be escalated without stem cell support, then a thrombopoietic agent will need to be used

  5. Antibiotic prescribing practices for catheter urine culture results.

    Science.gov (United States)

    Chiu, Jonathan; Thompson, G William; Austin, Thomas W; Hussain, Zafar; John, Michael; Bombassaro, Anne Marie; Connelly, Sarah E; Elsayed, Sameer

    2013-01-01

    The literature suggests that positive results of catheter urine cultures frequently lead to unnecessary antimicrobial prescribing, which therefore represents an important target for stewardship. To assess the appropriateness of antibiotic prescribing in response to the results of urine cultures from patients with indwelling urinary catheters. This retrospective study was conducted at a tertiary care centre and involved adults with indwelling urinary catheters from whom urine specimens were obtained for culture. Patients with positive or negative culture results were identified from microbiology laboratory reports. The medical records of consecutive patients were screened to select a sample of 80 inpatients (40 per group). Abstracted patient histories were independently evaluated by an expert panel of 3 infectious diseases consultants blinded to the decisions of prescribers and of fellow panelists. The primary end point was concordance of each patient's treatment decision (with respect to the indication) between the expert panel (based on majority agreement, i.e., at least 2 of the 3 expert panelists) and the prescriber. The secondary end points were unnecessary days of therapy and selected outcomes over a predefined period after urine was obtained for culture. A total of 591 charts were screened to generate the targeted number of patients. Baseline demographic characteristics were comparable for the 2 groups, except antibiotic exposure before urine collection was significantly more frequent for the group with negative culture results. The treatment decision was concordant in 40% (16/40) of the patients with a positive culture result and 85% (34/40) of those with a negative culture result (p < 0.001). The most common reason for discordance was administration of antibiotics when not indicated (23 of 24 patients with a positive result and 5 of 6 patients with a negative result), which accounted for 165 and 32 unnecessary days of therapy per 1000 inpatient

  6. Association of Industry Payments to Physicians With the Prescribing of Brand-name Statins in Massachusetts.

    Science.gov (United States)

    Yeh, James S; Franklin, Jessica M; Avorn, Jerry; Landon, Joan; Kesselheim, Aaron S

    2016-06-01

    Pharmaceutical industry payments to physicians may affect prescribing practices and increase costs if more expensive medications are prescribed. Determine the association between industry payments to physicians and the prescribing of brand-name as compared with generic statins for lowering cholesterol. Cross-sectional linkage of the Part D Medicare prescriptions claims data with the Massachusetts physicians payment database including all licensed Massachusetts physicians who wrote prescriptions for statins paid for under the Medicare drug benefit in 2011. The exposure variable was a physician's industry payments as listed in the Massachusetts database. The outcome was the physician's rate of prescribing brand-name statins. We used linear regression to analyze the association between the intensity of physicians' industry relationships (as measured by total payments) and their prescribing practices, as well as the effects of specific types of payments. Among the 2444 Massachusetts physicians in the Medicare prescribing database in 2011, 899 (36.8%) received industry payments. The most frequent payment was for company-sponsored meals (n = 639 [71.1%]). Statins accounted for 1 559 003 prescription claims; 356 807 (22.8%) were for brand-name drugs. For physicians with no industry payments listed, the median brand-name statin prescribing rate was 17.8% (95% CI, 17.2%-18.4%). For every $1000 in total payments received, the brand-name statin prescribing rate increased by 0.1% (95% CI, 0.06%-0.13%; P associated with a 4.8% increase in the rate of brand-name prescribing (P = .004); other forms of payments were not. Industry payments to physicians are associated with higher rates of prescribing brand-name statins. As the United States seeks to rein in the costs of prescription drugs and make them less expensive for patients, our findings are concerning.

  7. Antibiotic Prescribing Patterns in Outpatient Emergency Clinics at Queen Rania Al Abdullah II Children's Hospital, Jordan, 2013.

    Science.gov (United States)

    Al-Niemat, Sahar I; Aljbouri, Tareq M; Goussous, Lana S; Efaishat, Rania A; Salah, Rehab K

    2014-07-01

    To investigate antibiotics prescribing patterns in the outpatient pediatric emergency clinic at Queen Rania Al Abdullah II Children's Hospital at Royal Medical Services in Amman, Jordan. The data was collected from the emergency pharmacy over the period of a -five consecutive months. The methodology recommended by the World Health Organization for investigating drug use in a health facility was followed. The study measures the percentage of encounter with a prescribed antibiotic and the percentage share of each antibiotic category. The distribution of diagnostic categories that accounted for all antibiotics being prescribed and the distribution of each antibiotic being prescribed for upper respiratory tract infections (URTIs) were also measured. Antibiotic prescribing was frequent during pediatric visits to the outpatient pediatric emergency clinic resulting in a high percentage of encounters (85%) when compared to appropriate. Emergency physicians continue to frequently prescribe broad spectrum antibiotics which accounted for approximately (60%) of the total prescribed antibiotics and (83%) of prescribed antibiotics for upper respiratory tract infections and macrolides (primarily azithromycin) were the leading class among them. Our results showed high consumption of antibiotics by emergency department pediatricians which highlight the importance for interventions to promote rational and judicious prescribing. An insight into factors influencing antibiotics prescribing patterns by military prescribers is required.

  8. Antibiotic Prescribing Patterns in Outpatient Emergency Clinics at Queen Rania Al Abdullah II Children's Hospital, Jordan, 2013

    Directory of Open Access Journals (Sweden)

    Sahar I. Al-Niemat

    2014-07-01

    Full Text Available Objective: To investigate antibiotics prescribing patterns in the outpatient pediatric emergency clinic at Queen Rania Al Abdullah II Children’s Hospital at Royal Medical Services in Amman, Jordan. Methods: The data was collected from the emergency pharmacy over the period of a -five consecutive months. The methodology recommended by the World Health Organization for investigating drug use in a health facility was followed. The study measures the percentage of encounter with a prescribed antibiotic and the percentage share of each antibiotic category. The distribution of diagnostic categories that accounted for all antibiotics being prescribed and the distribution of each antibiotic being prescribed for upper respiratory tract infections (URTIs were also measured. Results: Antibiotic prescribing was frequent during pediatric visits to the outpatient pediatric emergency clinic resulting in a high percentage of encounters (85% when compared to appropriate. Emergency physicians continue to frequently prescribe broad spectrum antibiotics which accounted for approximately (60% of the total prescribed antibiotics and (83% of prescribed antibiotics for upper respiratory tract infections and macrolides (primarily azithromycin were the leading class among them. Conclusion: Our results showed high consumption of antibiotics by emergency department pediatricians which highlight the importance for interventions to promote rational and judicious prescribing. An insight into factors influencing antibiotics prescribing patterns by military prescribers is required.

  9. Advances in the implementation of helical tomotherapy-based total marrow irradiation with a novel field junction technique

    Energy Technology Data Exchange (ETDEWEB)

    Zeverino, Michele, E-mail: michele.zeverino@istge.it [Medical Physics Department, IRCCS, Istituto Nazionale per la Ricerca sul cancro, Genoa (Italy); Agostinelli, Stefano; Taccini, Gianni; Cavagnetto, Francesca; Garelli, Stefania; Gusinu, Marco [Medical Physics Department, IRCCS, Istituto Nazionale per la Ricerca sul cancro, Genoa (Italy); Vagge, Stefano; Barra, Salvina; Corvo, Renzo [Radiation Oncology Department, IRCCS, Istituto Nazionale per la Ricerca sul cancro, Genoa (Italy)

    2012-10-01

    Given the limitations in the travel ability of the helical tomotherapy (HT) couch, total marrow irradiation (TMI) has to be split in 2 segments, with the lower limbs treated with feet first orientation. The aim of this work is to present a planning technique useful to reduce the dose inhomogeneity resulting from the matching of the 2 helical dose distributions. Three HT plans were generated for each of the 18 patients enrolled. Upper TMI (UTMI) and lower TMI (LTMI) were planned onto the whole-body computed tomography (CT) and on the lower-limb CT, respectively. A twin lower TMI plan (tLTMI) was designed on the whole-body CT. Agreement between LTMI and tLTMI plans was assessed by computing for each dose-volume histogram (DVH) structure the {gamma} index scored with 1% of dose and volume difference thresholds. UTMI and tLTMI plans were summed together on the whole-body CT, enabling the evaluation of dose inhomogeneity. Moreover, a couple of transition volumes were used to improve the dose uniformity in the abutment region. For every DVH, a number of points >99% passed the {gamma} analysis, validating the method used to generate the twin plan. The planned dose inhomogeneity at the junction level resulted within {+-}10% of the prescribed dose. Median dose reduction to organs at risk ranged from 30-80% of the prescribed dose. Mean conformity index was 1.41 (range 1.36-1.44) for the whole-body target. The technique provided a 'full helical' dose distribution for TMI treatments, which can be considered effective only if the dose agreement between LTMI and tLTMI plans is met. The planning of TMI with HT for the whole body with adequate dose homogeneity and conformity was shown to be feasible.

  10. Modeling of outpatient prescribing process in iran: a gateway toward electronic prescribing system.

    Science.gov (United States)

    Ahmadi, Maryam; Samadbeik, Mahnaz; Sadoughi, Farahnaz

    2014-01-01

    Implementation of electronic prescribing system can overcome many problems of the paper prescribing system, and provide numerous opportunities of more effective and advantageous prescribing. Successful implementation of such a system requires complete and deep understanding of work content, human force, and workflow of paper prescribing. The current study was designed in order to model the current business process of outpatient prescribing in Iran and clarify different actions during this process. In order to describe the prescribing process and the system features in Iran, the methodology of business process modeling and analysis was used in the present study. The results of the process documentation were analyzed using a conceptual model of workflow elements and the technique of modeling "As-Is" business processes. Analysis of the current (as-is) prescribing process demonstrated that Iran stood at the first levels of sophistication in graduated levels of electronic prescribing, namely electronic prescription reference, and that there were problematic areas including bottlenecks, redundant and duplicated work, concentration of decision nodes, and communicative weaknesses among stakeholders of the process. Using information technology in some activities of medication prescription in Iran has not eliminated the dependence of the stakeholders on paper-based documents and prescriptions. Therefore, it is necessary to implement proper system programming in order to support change management and solve the problems in the existing prescribing process. To this end, a suitable basis should be provided for reorganization and improvement of the prescribing process for the future electronic systems.

  11. Understanding the determinants of antimicrobial prescribing within hospitals: the role of "prescribing etiquette".

    Science.gov (United States)

    Charani, E; Castro-Sanchez, E; Sevdalis, N; Kyratsis, Y; Drumright, L; Shah, N; Holmes, A

    2013-07-01

    There is limited knowledge of the key determinants of antimicrobial prescribing behavior (APB) in hospitals. An understanding of these determinants is required for the successful design, adoption, and implementation of quality improvement interventions in antimicrobial stewardship programs. Qualitative semistructured interviews were conducted with doctors (n = 10), pharmacists (n = 10), and nurses and midwives (n = 19) in 4 hospitals in London. Interviews were conducted until thematic saturation was reached. Thematic analysis was applied to the data to identify the key determinants of antimicrobial prescribing behaviors. The APB of healthcare professionals is governed by a set of cultural rules. Antimicrobial prescribing is performed in an environment where the behavior of clinical leaders or seniors influences practice of junior doctors. Senior doctors consider themselves exempt from following policy and practice within a culture of perceived autonomous decision making that relies more on personal knowledge and experience than formal policy. Prescribers identify with the clinical groups in which they work and adjust their APB according to the prevailing practice within these groups. A culture of "noninterference" in the antimicrobial prescribing practice of peers prevents intervention into prescribing of colleagues. These sets of cultural rules demonstrate the existence of a "prescribing etiquette," which dominates the APB of healthcare professionals. Prescribing etiquette creates an environment in which professional hierarchy and clinical groups act as key determinants of APB. To influence the antimicrobial prescribing of individual healthcare professionals, interventions need to address prescribing etiquette and use clinical leadership within existing clinical groups to influence practice.

  12. Cobalt-60 total body irradiation dosimetry at 220 cm source-axis distance

    International Nuclear Information System (INIS)

    Glasgow, G.P.; Mill, W.B.

    1980-01-01

    Adults with acute leukemia are treated with cyclophosphamide and total body irradiation (TBI) followed by autologous marrow transplants. For TBI, patients seated in a stand angled 45 0 above the floor are treated for about 2 hours at 220 cm source-axis distance (SAD) with sequential right and left lateral 87 cm x 87 cm fields to a 900 rad mid-pelvic dose at about 8 rad/min using a 5000 Ci cobalt unit. Maximum (lateral) to minimum (mid-plane) dose ratios are: hips--1.15, shoulders--1.30, and head--1.05, which is shielded by a compensator filter. Organ doses are small intestine, liver and kidneys--1100 rad, lung--1100 to 1200 rad, and heart--1300 rad. Verification dosimetry reveals the prescribed dose is delivered to within +-5%. Details of the dosimetry of this treatment are presented

  13. The effectiveness of Patient Controlled Analgesia (PCA morphine-ketamine compared to Patient Controlled Analgesia (PCA morphine to reduce total dose of morphine and Visual Analog Scale (VAS in postoperative laparotomy surgery

    Directory of Open Access Journals (Sweden)

    I Gusti Ngurah Mahaalit Aribawa

    2017-05-01

    Full Text Available Background: Laparotomy may cause moderate to severe after surgery pain, thus adequate pain management is needed. The addition of ketamine in patient controlled analgesia (PCA morphine after surgery can be the option. This study aims to evaluate the effectiveness of PCA morphine-ketamine compared to PCA morphine in patient postoperative laparotomy surgery to reduce total dose of morphine requirement and pain intensity evaluated with visual analog scale (VAS. Methods: This study was a double-blind RCT in 58 patients of ASA I and II, age 18-64 years, underwent an elective laparotomy at Sanglah General Hospital. Patients were divided into 2 groups. Group A, got addition of ketamine (1mg/ml in PCA morphine (1mg/ml and patients in group B received morphine (1mg/ml by PCA. Prior to surgical incision both group were given a bolus ketamine 0,15mg/ kg and ketorolac 0,5mg/kg. The total dose of morphine and VAS were measured at 6, 12, and 24 hours postoperatively. Result: Total dose of morphine in the first 24 hours postoperatively at morphine-ketamine group (5,1±0,8mg is lower than morphine only group (6,5±0,9mg p<0,001. VAS (resting 6 and 12 hour postoperative in morphine-ketamine group (13,4±4,8 mm and (10,7±2,6 mm are lower than morphine (17,9±4,1mm p≤0,05 and (12,8±5,3mm p≤0,05. VAS (moving 6, 12, and 24 hour postoperative morphineketamine group (24,8±5,1mm, (18±5,6mm and (9±5,6mm are lower than morphine (28,7±5,2mm p≤0,05, (23,1±6,0mm p≤0,05, and (12,8±5,3mm p≤0,05. Conclusions: Addition of ketamine in PCA morphine for postoperative laparotomy surgery reduces total morphine requirements in 24 hours compared to PCA morphine alone.

  14. Prescribing Practices and Polypharmacy in Kitovu Hospital

    African Journals Online (AJOL)

    admin

    1Division of Medicine and Therapeutics, Centre for Medical Education, The Queen's ... This audit of prescribing practices explores recent trends at Kitovu Hospital, Uganda ..... This creates a cycle of poor ... interventions to remedy these is vital.

  15. The social act of electronic medication prescribing

    NARCIS (Netherlands)

    J.E.C.M. Aarts (Jos)

    2013-01-01

    markdownabstract__Abstract__ Prescribing medication is embedded in social norms and cultures. In modern Western health care professionals and policy makers have attempted to rationalize medicine by addressing cost-effectiveness of diagnostic and therapeutic treatments and the development of

  16. Customization in prescribing for bipolar disorder.

    Science.gov (United States)

    Hodgkin, Dominic; Volpe-Vartanian, Joanna; Merrick, Elizabeth L; Horgan, Constance M; Nierenberg, Andrew A; Frank, Richard G; Lee, Sue

    2012-06-01

    For many disorders, patient heterogeneity requires physicians to customize their treatment to each patient's needs. We test for the existence of customization in physicians' prescribing for bipolar disorder, using data from a naturalistic clinical effectiveness trial of bipolar disorder treatment (STEP-BD), which did not constrain physician prescribing. Multinomial logit is used to model the physician's choice among five combinations of drug classes. We find that our observed measure of the patient's clinical status played only a limited role in the choice among drug class combinations, even for conditions such as mania that are expected to affect class choice. However, treatment of a patient with given characteristics differed widely depending on which physician was seen. The explanatory power of the model was low. There was variation within each physician's prescribing, but the results do not suggest a high degree of customization in physicians' prescribing, based on our measure of clinical status. Copyright © 2011 John Wiley & Sons, Ltd.

  17. Nurse prescribing ethics and medical marketing.

    Science.gov (United States)

    Adams, J

    This article suggests that nurse prescribers require an awareness of key concepts in ethics, such as deontology and utilitarianism to reflect on current debates and contribute to them. The principles of biomedical ethics have also been influential in the development of professional codes of conduct. Attention is drawn to the importance of the Association of the British Pharmaceutical Industry's code of practice for the pharmaceutical industry in regulating marketing aimed at prescribers.

  18. Prevalence of inappropriate prescribing in primary care

    DEFF Research Database (Denmark)

    Bregnhøj, Lisbeth; Thirstrup, Steffen; Kristensen, Mogens Brandt

    2007-01-01

    to the patients. Topical, dermatological medications and medications not used regularly were excluded. RESULTS: 212 patients were prescribed 1621 medications by their GPs at baseline. In all, 640 (39.5%) of the medications had one or more inappropriate ratings in the 10 criteria making up the MAI. The main part...... is good. However, the majority of patients used one or more medications with inappropriate ratings. The inappropriate prescribing relates to specific therapeutic groups and criteria, which should be targeted in future interventions....

  19. Nonadministration of medication doses for venous thromboembolism prophylaxis in a cohort of hospitalized patients.

    Science.gov (United States)

    Popoola, Victor O; Lau, Brandyn D; Tan, Esther; Shaffer, Dauryne L; Kraus, Peggy S; Farrow, Norma E; Hobson, Deborah B; Aboagye, Jonathan K; Streiff, Michael B; Haut, Elliott R

    2018-03-15

    Results of a study to characterize patterns of nonadministration of medication doses for venous thromboembolism (VTE) prevention among hospitalized patients are presented. The electronic records of all patients admitted to 4 floors of a medical center during a 1-month period were examined to identify patients whose records indicated at least 1 nonadministered dose of medication for VTE prophylaxis. Proportions of nonadministered doses by medication type, intended route of administration, and VTE risk categorization were compared; reasons for nonadministration were evaluated. Overall, 12.7% of all medication doses prescribed to patients in the study cohort ( n = 75) during the study period (857 of 6,758 doses in total) were not administered. Nonadministration of 1 or more doses of VTE prophylaxis medication was nearly twice as likely for subcutaneous anticoagulants than for all other medication types (231 of 1,112 doses [20.8%] versus 626 of 5,646 doses [11.2%], p < 0.001). For all medications prescribed, the most common reason for nonadministration was patient refusal (559 of 857 doses [65.2%]); the refusal rate was higher for subcutaneous anticoagulants than for all other medication categories (82.7% versus 58.8%, p < 0.001). Doses of antiretrovirals, immunosuppressives, antihypertensives, psychiatric medications, analgesics, and antiepileptics were less commonly missed than doses of electrolytes, vitamins, and gastrointestinal medications. Scheduled doses of subcutaneous anticoagulants for hospitalized patients were more likely to be missed than doses of all other medication types. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  20. The social act of electronic medication prescribing.

    Science.gov (United States)

    Aarts, Jos

    2013-01-01

    Prescribing medication is embedded in social norms and cultures. In modern Western health care professionals and policy makers have attempted to rationalize medicine by addressing cost-effectiveness of diagnostic and therapeutic treatments and the development of guidelines and protocols based on the outcomes of clinical studies. These notions of cost-effectiveness and evidence-based medicine have also been embedded in technology such as electronic prescribing systems. Such constraining systems may clash with the reality of clinical practice, where formal boundaries of responsibility and authorization are often blurred. Such systems may therefore even impede patient care. Medication is seen as the essence of medical practice. Prescribing is a social act. In a hospital medications may be aimed at treating a patient for a specific condition, in primary care the professional often meets the patient with her or his social and cultural notions of a health problem. The author argues that the design and implementation of electronic prescribing systems should address the social and cultural context of prescribing. Especially in primary care, where health problems are often ill defined and evidence-based medicine guidelines do not always work as intended, studies need to take into account the sociotechnical character of electronic prescribing systems.

  1. Adaptation of proton total dose with respect to dosimetric parameters within the frame of treatment of skull base or upper cervical spine chordomas; Adaptation de la dose totale de protons en fonction des parametres dosimetriques dans le cadre du traitement des chordomes de la base du crane et du rachis cervical haut

    Energy Technology Data Exchange (ETDEWEB)

    Hemery, C.G.; Mazeron, J.J.; Feuvret, L. [Groupe hospitalier Pitie-Salpetriere (AP-HP), 75 - Paris (France); Calugaru, V.; Bolle, S.; Habrand, J.L.; Datcharty, J.; Alapetite, C.; Dendale, R.; Feuvret, L. [Institut Curie-Centre de protontherapie d' Orsay, 91 (France); Habrand, J.L.; Datcharty, J. [Institut Gustave-Roussy, 94 - Villejuif (France); Noel, G. [Centre Paul-Strauss, 67 - Strasbourg (France)

    2010-10-15

    The authors report the study of the feasibility of a photon-proton irradiation protocol with a dose adaptation with respect to dosimetric factors for patients suffering form a skull base and upper cervical spine chordoma. Sixty patients have been treated between May 2006 and June 2008 with a combination of high energy photons and protons. As five tumours have locally relapsed and one at distance, the authors comment the local control rates, the number of attained cranial nerves, the value of the macroscopic tumour volume, the survival rate without relapse in terms of multifactorial of uni-factorial analysis. Short communication

  2. Prescribing pattern of general practitioners for osteoarthritis in primary care settings in Bolu, Turkey

    International Nuclear Information System (INIS)

    Kartal, M.; Maral, I.; Coskun, O.

    2007-01-01

    Objective was to assess the drug preferences of primary care physicians for osteoarthritis (OA) in comparison with the current guidelines and their reflections in the cost of prescriptions. Data were collected from all primary health care centers in Bolu, Turkey during from November 2002 from patient polyclinic logbooks. Drugs prescribed were classified according to the Anatomical Therapeutical Chemical Classification system for comparison purposes. Gender, age and health insurance of patients were analyzed for drug preferences and costs. Forty-eight primary care physicians prescribed 1047 drugs for 507 OA patients with total cost of $10,254. Anti-inflammatory and antirheumatic products were the leading group accounting for 59.6% of the prescribed drugs, and 84.1% of the total expenditure. Paracetamol, the most commonly recommended in the guidelines, constituted 6.9% of all prescribed drugs and 0.9% of the total cost. Drug preferences showed a statistical difference among the health insurance types while drugs cost showed statistical significance among the gender and health insurance types. Cyclooygenase-2-specific inhibitors were the most commonly prescribed subgroup, constituting 23.2% of prescribed drugs and 62.6% of the total expenditure. Paracetamol in practice was not the first-line drug preferred by primary care physicians. Drug prescription data showed that the preference of drugs was affected by health insurance types and the gender of patients in favor of expensive new drugs. There is a need for improvement of drug prescriptions to reflect current recommendations and guidelines. (author)

  3. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  4. Identifying practice-related factors for high-volume prescribers of antibiotics in Danish general practice

    DEFF Research Database (Denmark)

    Aabenhus, Rune; Siersma, Volkert Dirk; Sandholdt, Håkon

    2017-01-01

    practice-related factors driving high antibiotic prescribing rates. Results: We included 98% of general practices in Denmark (n = 1962) and identified a 10% group of high prescribers who accounted for 15% of total antibiotic prescriptions and 18% of critically important antibiotic prescriptions. Once case...... prescriptions issued over the phone compared with all antibiotic prescriptions; and a high number of consultations per 1000 patients. We also found that a low number of consultations per 1000 patients was associated with a reduced likelihood of being a high prescriber of antibiotics. Conclusions: An apparent...

  5. Occupational PAH Exposures during Prescribed Pile Burns

    Science.gov (United States)

    Robinson, M. S.; Anthony, T. R.; Littau, S. R.; Herckes, P.; Nelson, X.; Poplin, G. S.; Burgess, J. L.

    2008-01-01

    Wildland firefighters are exposed to particulate matter and gases containing polycyclic aromatic hydrocarbons (PAHs), many of which are known carcinogens. Our objective was to evaluate the extent of firefighter exposure to particulate and PAHs during prescribed pile burns of mainly ponderosa pine slash and determine whether these exposures were correlated with changes in urinary 1-hydroxypyrene (1-HP), a PAH metabolite. Personal and area sampling for particulate and PAH exposures were conducted on the White Mountain Apache Tribe reservation, working with 21 Bureau of Indian Affairs/Fort Apache Agency wildland firefighters during the fall of 2006. Urine samples were collected pre- and post-exposure and pulmonary function was measured. Personal PAH exposures were detectable for only 3 of 16 PAHs analyzed: naphthalene, phenanthrene, and fluorene, all of which were identified only in vapor-phase samples. Condensed-phase PAHs were detected in PM2.5 area samples (20 of 21 PAHs analyzed were detected, all but naphthalene) at concentrations below 1 μg m−3. The total PAH/PM2.5 mass fractions were roughly a factor of two higher during smoldering (1.06 ± 0.15) than ignition (0.55 ± 0.04 μg mg−1). There were no significant changes in urinary 1-HP or pulmonary function following exposure to pile burning. In summary, PAH exposures were low in pile burns, and urinary testing for a PAH metabolite failed to show a significant difference between baseline and post-exposure measurements. PMID:18515848

  6. Zolpidem prescribing practices before and after Food and Drug Administration required product labeling changes

    OpenAIRE

    Norman, Jessica L; Fixen, Danielle R; Saseen, Joseph J; Saba, Laura M; Linnebur, Sunny A

    2017-01-01

    Background: Women have higher morning serum zolpidem concentrations than men after taking an evening dose, potentially leading to increased risk of harm. On 19 April 2013, the United States Food and Drug Administration required labeling changes for zolpidem, recommending an initial dose of no greater than 5 mg (immediate release) or 6.25 mg (controlled release) per night in women. Objectives: The primary objective of this study was to compare prescribing practices before and after the 2013 zo...

  7. Estimation of benchmark dose as the threshold levels of urinary cadmium, based on excretion of total protein, β 2-microglobulin, and N-acetyl-β-D-glucosaminidase in cadmium nonpolluted regions in Japan

    International Nuclear Information System (INIS)

    Kobayashi, Etsuko; Suwazono, Yasushi; Uetani, Mirei; Inaba, Takeya; Oishi, Mitsuhiro; Kido, Teruhiko; Nishijo, Muneko; Nakagawa, Hideaki; Nogawa, Koji

    2006-01-01

    Previously, we investigated the association between urinary cadmium (Cd) concentration and indicators of renal dysfunction, including total protein, β 2 -microglobulin (β 2 -MG), and N-acetyl-β-D-glucosaminidase (NAG). In 2778 inhabitants ≥50 years of age (1114 men, 1664 women) in three different Cd nonpolluted areas in Japan, we showed that a dose-response relationship existed between renal effects and Cd exposure in the general environment without any known Cd pollution. However, we could not estimate the threshold levels of urinary Cd at that time. In the present study, we estimated the threshold levels of urinary Cd as the benchmark dose low (BMDL) using the benchmark dose (BMD) approach. Urinary Cd excretion was divided into 10 categories, and an abnormality rate was calculated for each. Cut-off values for urinary substances were defined as corresponding to the 84% and 95% upper limit values of the target population who have not smoked. Then we calculated the BMD and BMDL using a log-logistic model. The values of BMD and BMDL for all urinary substances could be calculated. The BMDL for the 84% cut-off value of β 2 -MG, setting an abnormal value at 5%, was 2.4 μg/g creatinine (cr) in men and 3.3 μg/g cr in women. In conclusion, the present study demonstrated that the threshold level of urinary Cd could be estimated in people living in the general environment without any known Cd-pollution in Japan, and the value was inferred to be almost the same as that in Belgium, Sweden, and China

  8. Assessing pediatrics residents' mathematical skills for prescribing medication: a need for improved training.

    Science.gov (United States)

    Glover, Mark L; Sussmane, Jeffrey B

    2002-10-01

    To evaluate residents' skills in performing basic mathematical calculations used for prescribing medications to pediatric patients. In 2001, a test of ten questions on basic calculations was given to first-, second-, and third-year residents at Miami Children's Hospital in Florida. Four additional questions were included to obtain the residents' levels of training, specific pediatrics intensive care unit (PICU) experience, and whether or not they routinely double-checked doses and adjusted them for each patient's weight. The test was anonymous and calculators were permitted. The overall score and the score for each resident class were calculated. Twenty-one residents participated. The overall average test score and the mean test score of each resident class was less than 70%. Second-year residents had the highest mean test scores, although there was no significant difference between the classes of residents (p =.745) or relationship between the residents' PICU experiences and their exam scores (p =.766). There was no significant difference between residents' levels of training and whether they double-checked their calculations (p =.633) or considered each patient's weight relative to the dose prescribed (p =.869). Seven residents committed tenfold dosing errors, and one resident committed a 1,000-fold dosing error. Pediatrics residents need to receive additional education in performing the calculations needed to prescribe medications. In addition, residents should be required to demonstrate these necessary mathematical skills before they are allowed to prescribe medications.

  9. Dosimetric evaluation of total marrow irradiation using 2 different planning systems

    International Nuclear Information System (INIS)

    Nalichowski, Adrian; Eagle, Don G.; Burmeister, Jay

    2016-01-01

    This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using the Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.

  10. Dosimetric evaluation of total marrow irradiation using 2 different planning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nalichowski, Adrian, E-mail: nalichoa@karmanos.org [Karmanos Cancer Center, Detroit, MI (United States); Eagle, Don G. [Wayne State University School of Medicine, Detroit, MI (United States); Burmeister, Jay [Karmanos Cancer Center, Detroit, MI (United States); Wayne State University School of Medicine, Detroit, MI (United States)

    2016-10-01

    This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using the Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.

  11. Peripheral blood corticotropin-releasing factor, adrenocorticotropic hormone and cytokine (Interleukin Beta, Interleukin 6, tumor necrosis factor alpha) levels after high- and low-dose total-body irradiation in humans

    International Nuclear Information System (INIS)

    Girinsky, T.A.; Pallardy, M.; Comoy, E.; Benassi, T.; Roger, R.; Ganem, G.; Socie, G.; Cossett, J.M.; Magdelenat, H.

    1994-01-01

    Total-body irradiation (TBI) induces an increase in levels of granulocytes and cortisol in blood. To explore the underlying mechanisms, we studied 26 patients who had TBI prior to bone marrow transplantation. Our findings suggest that only a high dose of TBI (10 Gy) was capable of activating the hypothalamopituitary area since corticotropin-releasing factor and blood adrenocorticotropic hormone levels increased at the end of the TBI. There was a concomitant increase in the levels of interleukin 6 and tumor necrosis factor in blood, suggesting that these cytokines might activate the hypothalamo-pituitary adrenal axis. Interleukin 1 was not detected. Since vascular injury is a common after radiation treatment, it is possible that interleukin 6 was secreted by endothelial cells. The exact mechanisms of the production of cyctokines induced by ionizing radiation remain to be determined. 25 refs., 1 fig

  12. The safety of meperidine prescribing in older adults: A longitudinal population-based study.

    Science.gov (United States)

    Friesen, Kevin J; Falk, Jamie; Bugden, Shawn

    2016-05-11

    Meperidine (pethidine) is an opioid analgesic that offers little advantage relative to other opioids and several disadvantages including limited potency, short duration of action, and the production of a neurotoxic metabolite (normeperidine) with a long half-life. Older adults are more sensitive to meperidine's side effects and may have diminished renal function which leads to the accumulation of normeperidine. The Institute for Safe Medication Practices has suggested avoiding meperidine in older adults, limiting its dose (≤600 mg/day) and duration of use (≤48 h). The objective of this study was to determine the level of meperidine use in older adults and assess the dosage and duration of meperidine with reference to these safety recommendations. A longitudinal study using administrative healthcare data was conducted to examine meperidine utilization and levels of high dose and extended duration prescribing among persons ≥65 years of age between April 1, 2001, and March 31, 2014 in Manitoba, Canada. The number of meperidine prescriptions, users, duration of treatment, defined daily doses (DDD) dispensed and number of prescribers were determined over the study period. In the Manitoba older adult population there was a marked decline in meperidine users and prescriptions from 2001 to 2014. There was an average use of 26.4 (95 % CI 24.0-28.8) DDDs of meperidine per user per year. While only 3.7 % of the prescriptions exceeded the 600 mg maximum daily dose, 96.7 % of prescriptions exceeded the recommended 2 days of therapy. For the remaining users of meperidine, the amount of meperidine used per person rose from 18.98 to 56.14 DDDs/user/year over the study period. The number of prescribers of meperidine declined throughout the study, but low DDD prescribers declined more quickly than high DDD prescribers. While meperidine use has declined, the remaining use appears to be decreasing in safety, with more meperidine prescribed per user. This seems to be driven by

  13. Renal toxicity after total body irradiation

    International Nuclear Information System (INIS)

    Borg, Martin; Hughes, Timothy; Horvath, Noemi; Rice, Michael; Thomas, Anthony C.

    2002-01-01

    Purpose: To evaluate the incidence of renal dysfunction after total body irradiation (TBI). Methods and Materials: Between 1990 and 1997, 64 patients (median age 50 years) received TBI as part of the conditioning regimen before bone marrow transplantation (BMT). Five patients with abnormal renal function at the beginning of treatment or with incomplete data were excluded. All patients received a total of 12 Gy (6 fractions twice daily for 3 consecutive days) prescribed to the peak lung dose (corrected for lung transmission) at a dose rate of 7.5 cGy/min. Renal shielding was not used. Renal dysfunction was assessed on the basis of the serum creatinine levels measured at the start and end of TBI and at 6, 12, 18, and 24 months after completion of BMT. Cox proportional hazard analysis was used to evaluate the various factors known to affect renal function. Results: Only 4 patients had elevated serum creatinine levels at 12 months and subsequently only 2 of the 33 surviving patients had persistent elevated renal serum creatinine levels 24 months after BMT. A fifth patient developed proteinuria and mildly elevated serum creatinine levels at 2.5 years. In 2 patients, the elevation coincided with disease relapse and normalized once remission was achieved. In the third patient, the elevation in serum creatinine levels coincided with relapse of multiple myeloma and the presence of Bence-Jones proteinuria. The fourth patient was the only patient who developed chronic renal failure secondary to radiation nephritis at 2 years. The etiology of the fifth patient's rise in creatinine was unknown, but may have been secondary to radiation nephritis. On univariate analysis, but not on multivariate analysis, a significant correlation was found between TBI-related renal dysfunction and hypertension before and after BMT. Conclusion: A dose of 12 Gy at 2 Gy/fraction resulted in only 1 case of radiation nephritis in the 59 patients studied 24 months after the completion of TBI and BMT

  14. Low Dose Total Body Irradiation Combined With Recombinant CD19-Ligand × Soluble TRAIL Fusion Protein is Highly Effective Against Radiation-resistant B-precursor Acute Lymphoblastic Leukemia in Mice

    Directory of Open Access Journals (Sweden)

    Fatih M. Uckun

    2015-04-01

    Full Text Available In high-risk remission B-precursor acute lymphoblastic leukemia (BPL patients, relapse rates have remained high post-hematopoietic stem cell transplantation (HSCT even after the use of very intensive total body irradiation (TBI-based conditioning regimens, especially in patients with a high “minimal residual disease” (MRD burden. New agents capable of killing radiation-resistant BPL cells and selectively augmenting their radiation sensitivity are therefore urgently needed. We report preclinical proof-of-principle that the potency of radiation therapy against BPL can be augmented by combining radiation with recombinant human CD19-Ligand × soluble TRAIL (“CD19L–sTRAIL” fusion protein. CD19L–sTRAIL consistently killed radiation-resistant primary leukemia cells from BPL patients as well as BPL xenograft cells and their leukemia-initiating in vivo clonogenic fraction. Low dose total body irradiation (TBI combined with CD19L–sTRAIL was highly effective against (1 xenografted CD19+ radiochemotherapy-resistant human BPL in NOD/SCID (NS mice challenged with an otherwise invariably fatal dose of xenograft cells derived from relapsed BPL patients as well as (2 radiation-resistant advanced stage CD19+ murine BPL with lymphomatous features in CD22ΔE12xBCR-ABL double transgenic mice. We hypothesize that the incorporation o