WorldWideScience

Sample records for total phosphoadenylate pool

  1. Total quality in spent fuel pool reracking

    International Nuclear Information System (INIS)

    Cranston, J.S.; Bradbury, R.B.; Cacciapouti, R.J.

    1993-01-01

    The nuclear utility environment is one of strict cost control under prescriptive regulations and increasing public scrutiny. This paper presents the results of A Total Quality approach, by a dedicated team, that addresses the need for increased on-site spent fuel storage in this environment. Innovations to spent fuel pool reracking, driven by utilities' specific technical needs and shrinking budgets, have resulted in both product improvements and lower prices. A Total Quality approach to the entire turnkey project is taken, thereby creating synergism and process efficiency in each of the major phases of the project: design and analysis, licensing, fabrication, installation and disposal. Specific technical advances and the proven quality of the team members minimizes risk to the utility and its shareholders and provides a complete, cost effective service. Proper evaluation of spent fuel storage methods and vendors requires a full understanding of currently available customer driven initiatives that reduce cost while improving quality. In all phases of a spent fuel reracking project, from new rack design and analysis through old rack disposal, the integration of diverse experts, at all levels and throughout all phases of a reracking project, better serves utility needs. This Total Quality environment in conjunction with many technical improvements results in a higher quality product at a lower cost

  2. Carbon pool densities and a first estimate of the total carbon pool in the Mongolian forest-steppe.

    Science.gov (United States)

    Dulamsuren, Choimaa; Klinge, Michael; Degener, Jan; Khishigjargal, Mookhor; Chenlemuge, Tselmeg; Bat-Enerel, Banzragch; Yeruult, Yolk; Saindovdon, Davaadorj; Ganbaatar, Kherlenchimeg; Tsogtbaatar, Jamsran; Leuschner, Christoph; Hauck, Markus

    2016-02-01

    The boreal forest biome represents one of the most important terrestrial carbon stores, which gave reason to intensive research on carbon stock densities. However, such an analysis does not yet exist for the southernmost Eurosiberian boreal forests in Inner Asia. Most of these forests are located in the Mongolian forest-steppe, which is largely dominated by Larix sibirica. We quantified the carbon stock density and total carbon pool of Mongolia's boreal forests and adjacent grasslands and draw conclusions on possible future change. Mean aboveground carbon stock density in the interior of L. sibirica forests was 66 Mg C ha(-1) , which is in the upper range of values reported from boreal forests and probably due to the comparably long growing season. The density of soil organic carbon (SOC, 108 Mg C ha(-1) ) and total belowground carbon density (149 Mg C ha(-1) ) are at the lower end of the range known from boreal forests, which might be the result of higher soil temperatures and a thinner permafrost layer than in the central and northern boreal forest belt. Land use effects are especially relevant at forest edges, where mean carbon stock density was 188 Mg C ha(-1) , compared with 215 Mg C ha(-1) in the forest interior. Carbon stock density in grasslands was 144 Mg C ha(-1) . Analysis of satellite imagery of the highly fragmented forest area in the forest-steppe zone showed that Mongolia's total boreal forest area is currently 73 818 km(2) , and 22% of this area refers to forest edges (defined as the first 30 m from the edge). The total forest carbon pool of Mongolia was estimated at ~ 1.5-1.7 Pg C, a value which is likely to decrease in future with increasing deforestation and fire frequency, and global warming. © 2015 John Wiley & Sons Ltd.

  3. Proposta do uso de pool de sangue total como controle interno de qualidade em hematologia

    OpenAIRE

    Schons,Carina Daniele; Tavares,Rejane Giacomelli

    2010-01-01

    INTRODUÇÃO: A confiabilidade dos resultados do laboratório é garantida pela realização do controle de qualidade, que tem como funções básicas análise, pesquisa e prevenção da ocorrência de erros laboratoriais por meio de programas que abrangem tanto o controle interno quanto o externo. OBJETIVO: Propor a padronização de utilização de pool de sangue total como controle interno de qualidade no setor de hematologia. MÉTODO: Foram selecionadas amostras de sangue total, colhidas com ácido etilenod...

  4. Solar swimming pool

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    This report examines the feasibility of using solar collectors to heat the water in a previously unheated outdoor swimming pool. The solar system is used in conjunction with a pool blanket, to conserve heat when the pool is not in use. Energy losses through evaporation can be reduced by as much as 70% by a pool blanket. A total of 130 m{sup 2} of highly durable black synthetic collectors were installed on a support structure at a 30{degree} angle from the horizontal, oriented to the south. Circulation of pool water though the collectors, which is controlled by a differential thermostat, was done with the existing pool pump. Before installation the pool temperature averaged 16{degree}C; after installation it ranged from 20{degree} to 26{degree}C. It was hard to distinguish how much pool heating was due to the solar system and how much heat was retained by the pool blanket. However, the pool season was extended by five weeks and attendance tripled. 2 figs.

  5. The success of assisted reproduction technologies in relation to composition of the total regulatory T cell (Treg) pool and different Treg subsets.

    Science.gov (United States)

    Schlossberger, V; Schober, L; Rehnitz, J; Schaier, M; Zeier, M; Meuer, S; Schmitt, E; Toth, B; Strowitzki, T; Steinborn, A

    2013-11-01

    Are there differences in composition of the total regulatory T cell (Treg) pool and distinct Treg subsets (naïve CD45RA(+)-Tregs, HLA-DR(-)- and HLA-DR(+)-memory Tregs) between successfully and non-successfully IVF/ICSI-treated women? Non-successfully IVF/ICSI-treated women have a decreased percentage of naïve CD45RA(+)-Tregs and an increased percentage of HLA-DR(-)-memory Tregs within the total Treg pool. Immunosuppressive Tregs play a significant role in human reproduction and studies have shown that their number and function are reduced in reproductive failure and complications of pregnancy such as pre-eclampsia and preterm labor. However, no data exist concerning the importance of Tregs for a successful outcome following assisted reproduction technologies. Blood samples were obtained from 210 women undergoing IVF/ICSI treatment, where 14 patients were excluded due to biochemical pregnancy or missed abortion. Age control blood samples were collected from 20 neonates and 176 healthy female volunteers. The study was performed between October 2010 and March 2012. In this study, we determined prospectively the quantity and composition of the total CD4(+)CD127(low+/-)CD25(+)FoxP3(+)-Treg pool and three different Treg subsets (naïve CD45RA(+)-Tregs, HLA-DR(-)- and HLA-DR(+)-memory Tregs) in all women undergoing IVF/ICSI treatment. We examined whether there were differences between those who became pregnant (n = 36) and those who did not (n = 160). The blood samples were collected within 1 h before the embryo transfer and analyzed by six-color flow cytometry. In order to evaluate these results with regard to the normal age-related changes in composition of the total Treg pool, the same analysis was performed using samples of umbilical cord blood and from healthy female volunteers aged between 17 and 76 years. The composition of the total Treg pool was documented for successfully IVF/ICSI-treated women (n = 5) throughout their pregnancy and we assessed the

  6. Proposta do uso de pool de sangue total como controle interno de qualidade em hematologia Proposal for the use of a pool of whole blood as internal quality control in hematology

    Directory of Open Access Journals (Sweden)

    Carina Daniele Schons

    2010-06-01

    Full Text Available INTRODUÇÃO: A confiabilidade dos resultados do laboratório é garantida pela realização do controle de qualidade, que tem como funções básicas análise, pesquisa e prevenção da ocorrência de erros laboratoriais por meio de programas que abrangem tanto o controle interno quanto o externo. OBJETIVO: Propor a padronização de utilização de pool de sangue total como controle interno de qualidade no setor de hematologia. MÉTODO: Foram selecionadas amostras de sangue total, colhidas com ácido etilenodiaminotetracético (EDTA, de mesmos grupo sanguíneo e fator Rh, livres de interferentes, como hemólise, lipemia e icterícia. De um total de 30 ml de sangue total, obtiveram-se três alíquotas de 10 ml cada, às quais foram adicionados, respectivamente, 0 ml (sem adição, 1 ml e 5 ml de glicerol (conservante. As amostras foram avaliadas em contador automático ADVIA® 60. Após determinação dos valores de média e DP, todas as amostras foram avaliadas por um período de 45 dias úteis para confecção do gráfico de Levey-Jennings e verificação da estabilidade da amostra. RESULTADO E CONCLUSÃO: Podemos verificar que o pool de sangue total, preparado de acordo com a metodologia proposta, não apresenta estabilidade necessária para sua utilização, como controle interno alternativo no setor de hematologia.INTRODUCTION: The reliability of laboratory results is ensured by the implementation of quality control, which has basic functions, such as analysis, research and prevention of laboratory errors through programs that encompass both internal and external control. OBJECTIVE: To propose a standard method to use pooled whole blood as internal quality control in the Hematology division. METHOD: The selected whole blood samples were collected with EDTA, belonged to the same blood group and Rh factor and did not present interfering factors, such as hemolysis, lipemia and icterus. From a total of 30 ml of whole blood it was obtained 3

  7. Benthic assemblages of rock pools in northern Portugal: seasonal and between-pool variability

    Directory of Open Access Journals (Sweden)

    Iacopo Bertocci

    2012-11-01

    Full Text Available We investigated the seasonal (winter vs summer and within season and spatial (between-pool variability of benthic assemblages of rock pools at mid-intertidal level along the shore of Viana do Castelo (North Portugal. Physical traits of rock pools, including size, depth and position along the shore, were also compared between pools. While pools did not differ for any of the examined physical traits, results indicated a clear seasonal difference in the structure of assemblages, including a total of 49 macroalgal and 13 animal taxa. This finding was driven by six taxa that are more abundant in winter (the reef-forming polychaete Sabellaria alveolata, the articulated coralline algae Corallina spp., the brown alga Bifurcaria bifurcata, the encrusting coralline alga Lithophyllum incrustans, the red alga Chondracanthus acicularis and the grazing snails Gibbula spp. and four algal taxa that are more abundant in summer (the invasive brown Sargassum muticum, the green Ulva spp., the kelp Laminaria ochroleuca and the filamentous red Ceramium spp.. These data provide a new contribution to the knowledge of rock pool systems and have potential implications for monitoring programmes aimed at assessing ecological modifications related to natural and anthropogenic disturbances and for identifying processes responsible for the variability of rock pool assemblages.

  8. A Giant Hepatic Hemangioma Complicated by Kasabach-Merritt Syndrome: Findings of Tc-99m RBC Scintigraphy and SPECT Including a Total Body Blood Pool Imaging Study

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Jeong, Hwan Jeong; Lim, Seok Tae; Kim, Dong Wook; Yim, Chang Yeol [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2009-02-15

    Kasabach-Merritt syndrome (KMS) consists of thrombocytopenia, microangiopathic hemolytic anemia, and localized consumption coagulopathy that develops within vascular hemangioma. This syndrome may also be associated with occult hemangiomas located at various sites. Tc-99m RBC scintigraphy and SPECT have proven to be reliable for confirming or excluding hemangioma. Total body blood pool imaging study during the scintigraphy also provides a means of screening for occult lesions. The authors report the case of a 29-year-old man who presented with a giant hepatic hemangioma complicated by KMS, and underwent Tc-99m RBC scintigraphy and SPECT including a total body blood pool imaging study.

  9. Detection of 41Ar diffusion from a TRIGA pool

    International Nuclear Information System (INIS)

    Foss, Scott; Nelson, George

    1990-01-01

    Argon-41 levels in very low concentrations in the reactor room air can be inferred from the rate of escape from the pool water surface. The rate of Argon-41 diffusion from pool water to room air was determined by the measurement of the activity buildup in containers of air in contact with the pool surface. The Argon-41 concentration in each container was measured by gamma-ray spectrometry with a calibrated GeLi detector. At 100 KW power with the water temperature at 10 deg. Celsius the total release of Argon-41 was determined to be 3.5e10±15% atoms for 80 minutes of operation. The corresponding activity released from the pool was 98.6 microcuries, while the total activity produced in the pool was 4900 microcuries. The diffusion coefficient of Argon-41 from the pool water surface to the air at this temperature was measured to be 3.14e-14 sec-cm 2 . (author)

  10. 13 CFR 120.611 - Pools backing Pool Certificates.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Pools backing Pool Certificates. 120.611 Section 120.611 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market Certificates § 120.611 Pools backing Pool Certificates. (a) Pool characteristics. As set...

  11. (Microbiological studies of small hot-bath-pools and hot-whirl-pools (author's transl))

    Energy Technology Data Exchange (ETDEWEB)

    Exner, M; Havenith, N

    1981-01-01

    Hot small bathing pools and hot whirl-pools have the following characteristics: small watervolume, thick squeeze of swimmers, high water temperature (37-40 degrees C) and small dimension of filters. By this, the quality of bathing-water is influenced detrimentally. To elaborate the hygienic problems, bathing-water samples were taken before, during and after the visiting-hours and were tested for facultative-pathogenic microorganisms. During this investigation E. coli was isolated in 25 degrees, Coliforms and Proteus species in 37.3%, P. aeruginosa in 36%, S. aureus in 26.3%, Enterococci in 42.3 %, Candida albicans in 3.6% and yeast totally in 8.3%.

  12. Seismic analysis of large pools

    Energy Technology Data Exchange (ETDEWEB)

    Dong, R.G.; Tokarz, F.J.

    1976-11-17

    Large pools for storing spent, nuclear fuel elements are being proposed to augment present storage capacity. To preserve the ability to isolate portions of these pools, a modularization requirement appears desirable. The purpose of this project was to investigate the effects of modularization on earthquake resistance and to assess the adequacy of current design methods for seismic loads. After determining probable representative pool geometries, three rectangular pool configurations, all 240 x 16 ft and 40 ft deep, were examined. One was unmodularized; two were modularized into 80 x 40 ft cells in one case and 80 x 80 ft cells in the other. Both embedded and above-ground installations for a hard site and embedded installations for an intermediate hard site were studied. It was found that modularization was unfavorable in terms of reducing the total structural load attributable to dynamic effects, principally because one or more cells could be left unfilled. The walls of unfilled cells would be subjected to significantly higher loads than the walls of a filled, unmodularized pool. Generally, embedded installations were preferable to above-ground installations, and the hard site was superior to the intermediate hard site. It was determined that Housner's theory was adequate for calculating hydrodynamic effects on spent fuel storage pools. Current design methods for seismic loads were found to be satisfactory when results from these methods were compared with those from LUSH analyses. As a design method for dynamic soil pressure, we found the Mononobe-Okabe theory, coupled with correction factors as suggested by Seed, to be acceptable. The factors we recommend for spent fuel storage pools are tabulated.

  13. Seismic analysis of large pools

    International Nuclear Information System (INIS)

    Dong, R.G.; Tokarz, F.J.

    1976-01-01

    Large pools for storing spent, nuclear fuel elements are being proposed to augment present storage capacity. To preserve the ability to isolate portions of these pools, a modularization requirement appears desirable. The purpose of this project was to investigate the effects of modularization on earthquake resistance and to assess the adequacy of current design methods for seismic loads. After determining probable representative pool geometries, three rectangular pool configurations, all 240 x 16 ft and 40 ft deep, were examined. One was unmodularized; two were modularized into 80 x 40 ft cells in one case and 80 x 80 ft cells in the other. Both embedded and above-ground installations for a hard site and embedded installations for an intermediate hard site were studied. It was found that modularization was unfavorable in terms of reducing the total structural load attributable to dynamic effects, principally because one or more cells could be left unfilled. The walls of unfilled cells would be subjected to significantly higher loads than the walls of a filled, unmodularized pool. Generally, embedded installations were preferable to above-ground installations, and the hard site was superior to the intermediate hard site. It was determined that Housner's theory was adequate for calculating hydrodynamic effects on spent fuel storage pools. Current design methods for seismic loads were found to be satisfactory when results from these methods were compared with those from LUSH analyses. As a design method for dynamic soil pressure, we found the Mononobe-Okabe theory, coupled with correction factors as suggested by Seed, to be acceptable. The factors we recommend for spent fuel storage pools are tabulated

  14. Titanium distribution in swimming pool water is dominated by dissolved species

    International Nuclear Information System (INIS)

    David Holbrook, R.; Motabar, Donna; Quiñones, Oscar; Stanford, Benjamin; Vanderford, Brett; Moss, Donna

    2013-01-01

    The increased use of titanium dioxide nanoparticles (nano-TiO 2 ) in consumer products such as sunscreen has raised concerns about their possible risk to human and environmental health. In this work, we report the occurrence, size fractionation and behavior of titanium (Ti) in a children's swimming pool. Size-fractionated samples were analyzed for Ti using ICP-MS. Total titanium concentrations ([Ti]) in the pool water ranged between 21 μg/L and 60 μg/L and increased throughout the 101-day sampling period while [Ti] in tap water remained relatively constant. The majority of [Ti] was found in the dissolved phase (<1 kDa), with only a minor fraction of total [Ti] being considered either particulate or microparticulate. Simple models suggest that evaporation may account for the observed variation in [Ti], while sunscreen may be a relevant source of particulate and microparticule Ti. Compared to diet, incidental ingestion of nano-Ti from swimming pool water is minimal. -- Highlights: •Total titanium concentrations in unfiltered swimming pool water ranged between 21 and 60 μg/L. •Evaporation of the swimming pool water is suspected of causing a temporal increase in [Ti]. •The vast majority of Ti is found in the dissolved phase (<1 kD). •Swimming pools are not a significant Ti source for human exposure via ingestion. -- In children's swimming pool water, the majority of titanium is found in the dissolved phase

  15. Dynamics of inorganic nutrients in intertidal sediments: porewater, exchangeable and intracellular pools

    Directory of Open Access Journals (Sweden)

    Emilio eGarcia-Robledo

    2016-05-01

    Full Text Available The study of inorganic nutrients dynamics in shallow sediments usually focuses on two main pools: the porewater (PW nutrients and the exchangeable (EX ammonium and phosphate. Recently, it has been found that microphytobenthos (MPB and other microorganisms can accumulate large amounts of nutrients intracellularly (IC, highlighting the biogeochemical importance of this nutrient pool. Storing nutrients could support the growth of autotrophs when nutrients are not available, and could also provide alternative electron acceptors for dissimilatory processes such as nitrate reduction. Here, we studied the magnitude and relative importance of these three nutrient pools (PW, IC and EX and their relation to chlorophylls (used as a proxy for MPB abundance and organic matter (OM contents in an intertidal mudflat of Cadiz Bay (Spain. MPB was localized in the first 4 mm of the sediment and showed a clear seasonal pattern; highest chlorophylls content was found during autumn and lowest during spring-summer. The temporal and spatial distribution of nutrients pools and MPB were largely correlated. Ammonium was higher in the IC and EX fractions, representing on average 59 and 37% of the total ammonium pool, respectively. Similarly, phosphate in the IC and EX fractions accounted on average for 40 and 31% of the total phosphate pool, respectively. Nitrate in the PW was low, suggesting low nitrification activity and rapid consumption. Nitrate accumulated in the IC pool during periods of moderate MPB abundance, being up to 66% of the total nitrate pool, whereas it decreased when chlorophyll concentration peaked likely due to a high nitrogen demand. EX-Nitrate accounted for the largest fraction of total sediment nitrate, 66% on average. The distribution of EX-Nitrate was significantly correlated with chlorophyll and OM, which probably indicates a relation of this pool to an increased availability of sites for ionic adsorption. This EX-Nitrate pool could represent an

  16. Structure of pool in reactor building

    International Nuclear Information System (INIS)

    Yokoyama, Shigeki.

    1997-01-01

    Shielding walls made of iron-reinforced concrete having a metal liner including two body walls rigidly combined to the upper surface of a reactor container are disposed at least to one of an equipment pool or spent fuel storage pool in a reactor building. A rack for temporarily placing an upper lattice plate is detachably attached at least above one of a steam dryer or a gas/liquid separator temporarily placed in the temporary pool, and the height from the bottom portion to the upper end of the shielding wall is determined based on the height of an upper lattice plate temporary placed on the rack and the water depth required for shielding radiation from the upper lattice plate. An operator's exposure on the operation floor can be reduced by the shielding wall, and radiation dose from the spent fuels is reduced. The increase of the height of a pool guarder enhances bending resistance as a ceiling. In addition, the total height of them is made identical with the depth of the spent fuel storage pool thereby enabling to increase storage area for spent fuels. (N.H.)

  17. Hawaii ESI: POOLS (Anchialine Pool Points)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains sensitive biological resource data for anchialine pools in Hawaii. Anchialine pools are small, relatively shallow coastal ponds that occur...

  18. Cash pooling

    OpenAIRE

    Lozovaya, Karina

    2009-01-01

    This work makes a mention of cash management. At next chapter describes two most known theoretical models of cash management -- Baumol Model and Miller-Orr Model. Principal part of work is about cash pooling, types of cash pooling, cash pooling at Czech Republic and influence of cash pooling over accounting and taxes.

  19. Nuclear Insurance Pools: Worldwide Practice and Development

    International Nuclear Information System (INIS)

    Reitsma, S. M. S.

    1998-01-01

    The development of nuclear installations to produce electricity led to the establishment of Nuclear Insurance Pools and the introduction of international Conventions on Third Party Liability. Nuclear Pools offer both Third Party Liability insurance, reflecting the Conventions' principles, and other insurance products. They are market-wide, providing a facility for participation by insurers who could not otherwise write the insurance for the particularly sensitive nuclear risk. All acceptances are for the net retention of each Member without recourse to individual reinsurance protection. Common account reinsurance is arranged with other Nuclear Pools all over the world. Thus, a transparency is created, which ensures the highest degree of reinsurance security and imposes a known finite limit to each participating insurer's commitment. Therefore, Pool-members are prepared to make a greater commitment to nuclear risks than would be case where they felt uncertain as regards their total exposure following a significant loss. (author)

  20. Numerical analysis of weld pool oscillation in laser welding

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jung Ho [Chungbuk National University, Cheongju (Korea, Republic of); Farson, Dave F [The Ohio State University, Columbus (United States); Hollis, Kendall; Milewski, John O. [Los Alamos National Laboratory, Los Alamos (United States)

    2015-04-15

    Volume of fluid (VOF) numerical simulation was used to investigate melt flow and volumetric oscillation of conduction-mode pulsed laser weld pools. The result is compared to high speed video stream of titanium laser spot welding experiment. The total simulation time is 10ms with the first 5 ms being heating and melting under constant laser irradiation and the remaining 5 ms corresponding to resolidification of the weld pool. During the melting process, the liquid pool did not exhibit periodic oscillation but was continually depressed by the evaporation recoil pressure. After the laser pulse, the weld pool was excited into volumetric oscillation by the release of pressure on its surface and oscillation of the weld pool surface was analyzed. The simulation model suggested adjusting thermal diffusivity to match cooling rate and puddle diameter during solidification which is distinguishable from previous weld pool simulation. The frequency continuously increased from several thousand cycles per second to tens of thousands of cycles per second as the weld pool solidified and its diameter decreased. The result is the first trial of investigation of small weld pool oscillation in laser welding although there have been several reports about arc welding.

  1. Determination of human and Sprague-Dawley rat trimethylseleonium ion and total selenium urine concentrations from endogenous body selenium pool by neutron activation analysis

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Claassen, J.P.; Rack, E.P.

    1992-01-01

    This study determined trimethylselenonium ion [TMSe,(CH 3 ) 3 Se + ] and total organic selenium cationic species urinary excretion values for healthy human subjects and Sprague-Dawley rats fed regular diets. The only source of TMSe was from the endogenous selenium body pool. Total selenium concentration in urine was determined by instrumental neutron activation analysis. TMSe and total selenium cationic species concentrations and percent of total selenium urine excretion were determined by chemical neutron activation analysis and coupled anion-cation exchange chromatography and anion-exchange chromatography, respectively. Within experimental error, mean values for TMSe and cationic species as percent selenium were comparable for both human subjects and Sprague-Dawley rats. This study suggested that TMSe excreated in urine by healthy human subjects and Sprague-Dawley rats fed a normal diet is not a minor but a general metabolite of selenium ingested in a normal diet. (author) 27 refs.; 1 fig.; 2 tabs

  2. 3D finite element simulation of TIG weld pool

    Science.gov (United States)

    Kong, X.; Asserin, O.; Gounand, S.; Gilles, P.; Bergheau, J. M.; Medale, M.

    2012-07-01

    The aim of this paper is to propose a three-dimensional weld pool model for the moving gas tungsten arc welding (GTAW) process, in order to understand the main factors that limit the weld quality and improve the productivity, especially with respect to the welding speed. Simulation is a very powerful tool to help in understanding the physical phenomena in the weld process. A 3D finite element model of heat and fluid flow in weld pool considering free surface of the pool and traveling speed has been developed for the GTAW process. Cast3M software is used to compute all the governing equations. The free surface of the weld pool is calculated by minimizing the total surface energy. The combined effects of surface tension gradient, buoyancy force, arc pressure, arc drag force to drive the fluid flow is included in our model. The deformation of the weld pool surface and the welding speed affect fluid flow, heat flow and thus temperature gradients and molten pool dimensions. Welding trials study is presented to compare our numerical results with macrograph of the molten pool.

  3. Evaluation of Total Coliform, Fecal Coliform and Residual Chlorine in Swimming Pools in Kermanshah on the Season, the type of Pool, Disinfection System and Source of Water Supply in the during of three years (2010-2012

    Directory of Open Access Journals (Sweden)

    K SHarafi

    2014-11-01

    From the results , although the pools of water quality parameters has been studied in almost ideal But in summer, especially on a female pools and pools with wells water supply source than other pools , to be more oversight .

  4. Mathematical modelling and simulation of the thermal performance of a solar heated indoor swimming pool

    Directory of Open Access Journals (Sweden)

    Mančić Marko V.

    2014-01-01

    Full Text Available Buildings with indoor swimming pools have a large energy footprint. The source of major energy loss is the swimming pool hall where air humidity is increased by evaporation from the pool water surface. This increases energy consumption for heating and ventilation of the pool hall, fresh water supply loss and heat demand for pool water heating. In this paper, a mathematical model of the swimming pool was made to assess energy demands of an indoor swimming pool building. The mathematical model of the swimming pool is used with the created multi-zone building model in TRNSYS software to determine pool hall energy demand and pool losses. Energy loss for pool water and pool hall heating and ventilation are analyzed for different target pool water and air temperatures. The simulation showed that pool water heating accounts for around 22%, whereas heating and ventilation of the pool hall for around 60% of the total pool hall heat demand. With a change of preset controller air and water temperatures in simulations, evaporation loss was in the range 46-54% of the total pool losses. A solar thermal sanitary hot water system was modelled and simulated to analyze it's potential for energy savings of the presented demand side model. The simulation showed that up to 87% of water heating demands could be met by the solar thermal system, while avoiding stagnation. [Projekat Ministarstva nauke Republike Srbije, br. III 42006: Research and development of energy and environmentally highly effective polygeneration systems based on using renewable energy sources

  5. Environmental controls of C, N and P biogeochemistry in peatland pools.

    Science.gov (United States)

    Arsenault, Julien; Talbot, Julie; Moore, Tim R

    2018-08-01

    Pools are common in northern peatlands but studies have seldom focused on their nutrient biogeochemistry, especially in relation to their morphological characteristics and through seasons. We determined the environmental characteristics controlling carbon (C), nitrogen (N) and phosphorus (P) biogeochemistry in pools and assessed their evolution over the course of the 2016 growing season in a subboreal ombrotrophic peatland of eastern Canada. We showed that water chemistry variations in 62 pools were significantly explained by depth (81.9%) and the surrounding vegetation type (14.8%), but not by pool area or shape. Shallow pools had larger dissolved organic carbon (DOC) and total nitrogen (TN) concentrations and lower pH than deep pools, while pools surrounded by coniferous trees had more recalcitrant DOC than pools where vegetation was dominated by mosses. The influence of depth on pool biogeochemistry was confirmed by the seasonal survey of pools of different sizes with 47.1% of the variation in pool water chemistry over time significantly explained. Of this, 67.3% was explained by the interaction between time and pool size and 32.7% by pool size alone. P concentrations were small in all pools all summer long and combined with high N:P ratios, are indicative of P-limitation. Our results show that pool biogeochemistry is influenced by internal processes and highlight the spatial and temporal heterogeneity of nutrient biogeochemistry in ombrotrophic peatlands. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Analysis of a total loss of pool water accident in MTR-type research reactors

    International Nuclear Information System (INIS)

    Yilmazer, A.; Yavuz, H.

    2004-01-01

    In this study, the transient in which the pool water is lost throughout one or more of the main coolant pipes which are supposed to be broken guillotine-like is investigated for the TR-2 research reactor in Istanbul. The applicability of the methods used for other similar types of research reactors is shown. Decrease of the pool water level until the top of the core, and from the top to the bottom of the core are examined as two successive phases of the accident. Finite difference scheme and integral methods are employed to solve energy equations and the results of both methods are compared. The finite difference solution uses an explicit form for the analysis of the first phase, and a moving boundary approach for the second phase. The integral method is based on the assumption that the temperatures appearing in the energy equations have the same profiles during the transient as the steady state ones. Analyses are done both for nominal and hot channel, and the results of both methods are observed to be in agreement. (orig.)

  7. Analysis of a total loss of pool water accident in MTR-type research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yilmazer, A. [Hacettepe University, Ankara (Turkey). Nuclear Engineering Department; Yavuz, H. [Istanbul Technical University (Turkey). Energy Institute

    2004-08-01

    In this study, the transient in which the pool water is lost throughout one or more of the main coolant pipes which are supposed to be broken guillotine-like is investigated for the TR-2 research reactor in Istanbul. The applicability of the methods used for other similar types of research reactors is shown. Decrease of the pool water level until the top of the core, and from the top to the bottom of the core are examined as two successive phases of the accident. Finite difference scheme and integral methods are employed to solve energy equations and the results of both methods are compared. The finite difference solution uses an explicit form for the analysis of the first phase, and a moving boundary approach for the second phase. The integral method is based on the assumption that the temperatures appearing in the energy equations have the same profiles during the transient as the steady state ones. Analyses are done both for nominal and hot channel, and the results of both methods are observed to be in agreement. (orig.)

  8. Reserve growth in oil pools of Alberta : model and forecast

    Energy Technology Data Exchange (ETDEWEB)

    Verma, M.; Cook, T. [United States Geological Survey, Denver, CO (United States). Central Region

    2010-09-15

    This paper presented a reserve growth study that was conducted on oil pools in Alberta, Canada. Historical oil reserve data were evaluated to assess the potential for future reserve growth in both pools and fields, and reserve growth models and functions were developed to better forecast hydrocarbon volumes. The study also considered the sensitivity of reserve growth to such factors as pool size, porosity, and oil gravity. From 1960 to 2005, the reported known recoverable oil in Alberta, excluding the Athabasca oil sands and including only pools with adequate data, increased from 4.2 to 13.9 billion barrels of oil (BBO). New discoveries contributed 3.7 BBO and reserve growth added 6 BBO. Most reserve growth occurred in pools with more than 125,000 barrels of oil. Light-oil pools account for most of the total known oil volume and consequently showed the lowest growth. Pools with greater than 30 percent porosity grew more than pools with lower porosity reservoirs. Oil field growth was found to be almost twice that of pool growth, possibly because the analysis evaluated fields with two or more pools discovered in different years. The growth in oil volumes in Alberta pools is projected to be about 454 million barrels of oil in the period from 2006 to 2010. Over a 25-year period, the cumulative reserve growth in Alberta oil pools was substantially lower than other major petroleum-producing regions, but the growth at the field level compares well. 8 refs., 2 tabs., 9 figs.

  9. Mathematical modeling of the energy consumption of heated swimming pools

    Energy Technology Data Exchange (ETDEWEB)

    Le Bel, C.; Millette, J. [LTE Shawinigan, Shawinigan, PQ (Canada)

    2007-07-01

    A mathematical model was developed to estimate the water temperature of a residential swimming pool. The model can compare 2 different situations and, if local climatic conditions are known, it can accurately predict energy costs of the pool relative to the total energy consumption of the house. When used with the appropriate energy transfer coefficient and weather file, the model can estimate the water temperature of a residential swimming pool having specific characteristics, such as in-ground, above-ground, heated or non-heated. The model is suitable for determining residential loads. It can be applied to different pool types and sizes, for different water heating scenarios and different climatic regions. Data obtained from the monitoring of water temperature and electricity use of 57 residential swimming pools was used to validate the model. In addition, 5 above-ground pools were installed on the property of LTE Shawinigan to allow for a more detailed study of the parameters involved in the thermal balance of a pool. The mathematical model, based on a global heat transfer coefficient, can determine the effect of a solar blanket and the effect of water volume. 14 refs., 5 tabs., 11 figs.

  10. Crustacean communities in coastal ephemeral pools in the Araucanía region (38° S, Chile).

    Science.gov (United States)

    De Los Ríos-Escalante, P; Acevedo, P

    2016-01-01

    The fauna communities of ephemeral pools in southern Chile are characterized by heterogeneity of crustacean taxa; nevertheless, no detailed studies exist of their community structure. The aim of the present study was to analyze the crustacean community structure in two groups of ephemeral pools (Puaucho and Nigue pools) in the coastal zone of the Araucanía region. A correlation matrix was made by species abundance against temperature, conductivity, pH and total dissolved solids. In a second step, a null model for species co-occurrence was applied to the total data and to each group. The results for total data revealed a significant direct relation between the abundance of H. costera, C. dubia and Mesocyclops. For the Puaucho pools, the same results were found together with direct associations with total dissolved solids, conductivity and pH. Finally, different results were found for the Nigue pools, with no clear significant associations, either direct or indirect, between the abundance of different crustacean taxa and abiotic parameters. These results were supported by the co-occurrence null model analysis, which revealed the presence of regulator factors for the total data, and for each of the two groups. Ecological topics are discussed with emphasis on meta-community dynamics.

  11. Exciting Pools

    Science.gov (United States)

    Wright, Bradford L.

    1975-01-01

    Advocates the creation of swimming pool oscillations as part of a general investigation of mechanical oscillations. Presents the equations, procedure for deriving the slosh modes, and methods of period estimation for exciting swimming pool oscillations. (GS)

  12. Pool swell sub-scale testing and code comparison

    International Nuclear Information System (INIS)

    Elisson, K.

    1981-01-01

    The main objective of the experiment was to investigate the pool swell dynamics in general and the forces on the lowered central part of the diaphragm between drywell and wetwell in particular. Apart from the high speed camera pressure transducers and strain gauges were used to monitor the transient. Data was recorded on a 14 channel FM recorder and then digitalised and plotted. In total more than one hundred tests were performed including parametric variations of for example geometry, break flow, initial drywell pressure and initial water level. In parallel to this experiment pool swell calculations have been performed with the computer codes COPTA and STEALTH. COPTA which is a lumped mass code for pressure suppression containment analysis has a slug pool swell mode. STEALTH which is a general purpose lagrangian hydrodynamics code has been used in a 2-D axisymmetric version. The STEALTH code has been used to calculate the radial variations in the vertical displacement and velocity of the pool surface and to predict the load on the lowered central part of the diaphragm. A comparison between the calculations and the experimental data indicates that both codes are sufficiently correct in their description of the pool swell transient. (orig.)

  13. Preliminary Calculation on a Spent Fuel Pool Accident using GOTHIC

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jaehwan; Choi, Yu Jung; Hong, Tae Hyub; Kim, Hyeong-Taek [KHNP-CRI, Daejeon (Korea, Republic of)

    2015-10-15

    The probability of an accident happening at the spent fuel pool was believed to be quite low until the 2011 Fukushima accident occurred. Notably, large amount of spent fuel are normally stored in the spent fuel pool for a long time compared to the amount of fuel in the reactor core and the total heat released from the spent fuel is high enough to boil the water of the spent fuel pool when the cooling system does not operate. In addition, the enrichment and the burnup of the fuel have both increased in the past decade and heat generation from the spent fuel thereby has also increased. The failure of the cooling system at the spent fuel pool (hereafter, a loss-of-cooling accident) is one of the principal hypothetical causes of an accident that could occur at the spent fuel pool. In this paper, the preliminary calculation of a loss-of-cooling accident was performed. In this paper, the preliminary calculation of a loss-of cooling accident was performed with GOTHIC. The calculation results show boiling away of water in the spent fuel pool due to the loss-of-cooling accident and similar thermal performance of the spent fuel pool with previous research results.

  14. CO{sub 2} flooding performance prediction for Alberta oil pools

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, J.C. [Adams Pearson Associates Inc., Calgary, AB (Canada); Bachu, S. [Alberta Energy and Utilities Board, Calgary, AB (Canada)

    2002-06-01

    An advanced technical screening program was used to successfully screen and rank a very large number of Alberta oil pools for enhanced oil recovery using carbon dioxide (CO{sub 2}) flooding. This paper is a continuation paper describing the results of using the Microsoft Excel program with VBA to estimate production forecasts for several candidate pools in Alberta. A total of 6 ranking parameters were used, including API gravity of oil, residual oil saturation, ratio between reservoir pressure and minimum miscibility pressure, reservoir temperature, net pay thickness and porosity. The screening program provides a technical ranking of approximately 8,000 Alberta pools. After compilation of the Alberta oil pools, it was determined that most of the deep carbonate oil pools are excellent candidates for CO{sub 2} miscible flooding. Other Devonian carbonate pools are also ranked as having high potential for the process. An environmental benefit of CO{sub 2} miscible flooding process is that carbon sequestration has the potential to reduce anthropogenic carbon dioxide emissions from reaching the atmosphere. Ongoing studies are currently addressing CO{sub 2} capture and transportation, making EOR technology viable for maintaining light oil production in western Canada. 11 refs., 2 tabs., 2 figs.

  15. Swimming-pool piles

    International Nuclear Information System (INIS)

    Trioulaire, M.

    1959-01-01

    In France two swimming-pool piles, Melusine and Triton, have just been set in operation. The swimming-pool pile is the ideal research tool for neutron fluxes of the order of 10 13 . This type of pile can be of immediate interest to many research centres, but its cost must be reduced and a break with tradition should be observed in its design. It would be an advantage: - to bury the swimming-pool; - to reject the experimental channel; - to concentrate the cooling circuit in the swimming-pool; - to carry out all manipulations in the water; - to double the core. (author) [fr

  16. Spent fuel storage pool

    International Nuclear Information System (INIS)

    Murakami, Naoshi.

    1996-01-01

    Fences are disposed to a fuel exchange floor surrounding the upper surface of a fuel pool for preventing overflow of pool water. The fences comprise a plurality of flat boards arranged in parallel with each other in the longitudinal direction while being vertically inclined, and slits are disposed between the boards for looking down the pool. Further, the fences comprise wide boards and are constituted so as to be laid horizontally on the fuel exchange floor in a normal state and uprisen by means of the signals from an earthquake sensing device. Even if pool water is overflow from the fuel pool by the vibrations occurred upon earthquake and flown out to the floor of the fuel exchange floor, the overflow from the fuel exchange floor is prevented by the fences. An operator who monitors the fuel pool can observe the inside of the fuel pool through the slits formed to the fences during normal operation. The fences act as resistance against overflowing water upon occurrence of an earthquake thereby capable of reducing the overflowing amount of water due to the vibrations of pool water. The effect of preventing overflowing water can be enhanced. (N.H.)

  17. Regional variation in the biogeochemical and physical characteristics of natural peatland pools.

    Science.gov (United States)

    Turner, T Edward; Billett, Michael F; Baird, Andy J; Chapman, Pippa J; Dinsmore, Kerry J; Holden, Joseph

    2016-03-01

    Natural open-water pools are a common feature of northern peatlands and are known to be an important source of atmospheric methane (CH4). Pool environmental variables, particularly water chemistry, vegetation community and physical characteristics, have the potential to exert strong controls on carbon cycling in pools. A total of 66 peatland pools were studied across three regions of the UK (northern Scotland, south-west Scotland, and Northern Ireland). We found that within-region variability of pool water chemistry was low; however, for many pool variables measured there were significant differences between regions. PCA analysis showed that pools in SW Scotland were strongly associated with greater vegetative cover and shallower water depth which is likely to increase dissolved organic carbon (DOC) mineralisation rates, whereas pools in N Scotland were more open and deeper. Pool water DOC, particulate organic carbon and dissolved CH4 concentrations were significantly different between regions. Pools in Northern Ireland had the highest concentrations of DOC (mean=14.5 mg L(-1)) and CH4 (mean=20.6 μg C L(-1)). Chloride and sulphate concentrations were significantly higher in the pools in N Scotland (mean values 26.3 and 2.40 mg L(-1), respectively) than elsewhere, due to a stronger marine influence. The ratio of UV absorbance at 465 nm to absorbance at 665 nm for pools in Northern Ireland indicated that DOC was sourced from poorly humified peat, potentially increasing the bioavailability and mineralisation of organic carbon in pools compared to the pools elsewhere. This study, which specifically aims to address a lack of basic biogeochemical knowledge about pool water chemistry, clearly shows that peatland pools are highly regionally variable. This is likely to be a reflection of significant regional-scale differences in peatland C cycling. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Gene Pools and the Genetic Architecture of Domesticated Cowpea

    Directory of Open Access Journals (Sweden)

    Bao-Lam Huynh

    2013-11-01

    Full Text Available Cowpea [ (L. Walp.] is a major tropical legume crop grown in warm to hot areas throughout the world and especially important to the people of sub-Saharan Africa where the crop was domesticated. To date, relatively little is understood about its domestication origins and patterns of genetic variation. In this study, a worldwide collection of cowpea landraces and African ancestral wild cowpea was genotyped with more than 1200 single nucleotide polymorphism markers. Bayesian inference revealed the presence of two major gene pools in cultivated cowpea in Africa. Landraces from gene pool 1 are mostly distributed in western Africa while the majority of gene pool 2 are located in eastern Africa. Each gene pool is most closely related to wild cowpea in the same geographic region, indicating divergent domestication processes leading to the formation of two gene pools. The total genetic variation within landraces from countries outside Africa was slightly greater than within African landraces. Accessions from Asia and Europe were more related to those from western Africa while accessions from the Americas appeared more closely related to those from eastern Africa. This delineation of cowpea germplasm into groups of genetic relatedness will be valuable for guiding introgression efforts in breeding programs and for improving the efficiency of germplasm management.

  19. Operation and maintenance techniques of pool and pool water purification system in IMEF

    Energy Technology Data Exchange (ETDEWEB)

    Soong, Woong Sup

    1999-03-01

    IMEF pool is used pass way between pool and hot cell in order to inlet and outlet of fuel pin in cask. All operation is performed conforming with naked eyes. Therefore floating matter is filtered so as to easy under water handling. Also radioactivity in pool water is controlled according to the nuclear law, radioactivity ration maintained less than 15mR/hr on pool side. Perfect operation and maintenance can be achieved well trained operator. Result obtained from the perfection can give more influence over restrain, spreading contamination of radioactivity materials. This report describes operation and maintenance technique of pool water purification system in IMEF. (Author). 7 refs., 13 figs.

  20. Operation and maintenance techniques of pool and pool water purification system in IMEF

    International Nuclear Information System (INIS)

    Soong, Woong Sup

    1999-03-01

    IMEF pool is used pass way between pool and hot cell in order to inlet and outlet of fuel pin in cask. All operation is performed conforming with naked eyes. Therefore floating matter is filtered so as to easy under water handling. Also radioactivity in pool water is controlled according to the nuclear law, radioactivity ration maintained less than 15mR/hr on pool side. Perfect operation and maintenance can be achieved well trained operator. Result obtained from the perfection can give more influence over restrain, spreading contamination of radioactivity materials. This report describes operation and maintenance technique of pool water purification system in IMEF. (Author). 7 refs., 13 figs

  1. Swimming pool granuloma

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001357.htm Swimming pool granuloma To use the sharing features on this page, please enable JavaScript. A swimming pool granuloma is a long-term (chronic) skin ...

  2. An approach to optimised control of HVAC systems in indoor swimming pools

    Science.gov (United States)

    Ribeiro, Eliseu M. A.; Jorge, Humberto M. M.; Quintela, Divo A. A.

    2016-04-01

    Indoor swimming pools are recognised as having a high level of energy consumption and present a great potential for energy saving. The energy is spent in several ways such as evaporation heat loss from the pool, high rates of ventilation required to guarantee the indoor air quality, and ambient temperatures with expressive values (typically 28-30°C) required to maintain conditions of comfort. This paper presents an approach to optimising control of heat ventilation and air conditioning systems that could be implemented in a building energy management system. It is easily adapted to any kind of pool and results in significant energy consumption reduction. The development and validation of the control model were carried out with a building thermal simulation software. The use of this control model in the case study building could reduce the energy efficiency index by 7.14 points (7.4% of total) which adds up to an energy cost saving of 15,609€ (7.5% of total).

  3. Swimming pool hydraulics and their significance for public pools. Bedeutung der Beckenhydraulik in oeffentlichen Schwimmbaedern

    Energy Technology Data Exchange (ETDEWEB)

    Gansloser, G

    1989-11-01

    The term of swimming pool hydraulics means the process of letting in and drawing off water to and from the pool while ensuring that no inadmissible water-borne contaminant concentrations will occur anywhere within the pool. Measurements were performed on a pool to study the significance of correct pool hydraulics. The author points out that a wrong water recirculation design will bring to nought the effects of an elaborate water treatment system; by contrast, poor pool water quality can be greatly improved by redesigning the pool water hydraulics approach. In principle, systems with with water inlet at one side and water outlet at the far side will fall short of hygienic requirements. (BWI).

  4. 31P-NMR differentiation between intracellular phosphate pools in Cosmarium (chlorophyta)

    International Nuclear Information System (INIS)

    Elgavish, A.; Elgavish, G.A.

    1980-01-01

    31 P nuclear magnetic resonance (NMR) spectroscopy of intact Cosmarium sp. cells is presented as a suitable tool for the differentiation of intracellular accumulation pools of polyphosphates. The cold trichloroacetic acid (TCA) insoluble fraction is shown to contain most of the total cellular phosphate in the phosphate rich Cosmarium cells. Moreover, evidence from a 31 P-NMR study and electron microscopic observations of cold TCA treated Cosmarium cells indicate that this fraction consists mostly of polyphosphates which seem to retain the native morphological structure observed in the untreated cells. The determination of orthophosphate in the hot water extract of Cosmarium cells did not measure the polyphosphate pools. Determination of total phosphorus content in the hot water extract rendered a value three times higher than the frequently used orthophosphate determination procedure. However, as revealed by the 31 P-NMR spectra and the chemical analyses of the extract and of the treated cells, even total phosphorus in the extract measured only 30% of the total cellular phosphorus. 31 P-NMR enabled the unequivocal chemical identification of the major phosphate compounds in the hot water extract (Surplus P) as orthophosphate and polyphosphates of about 10 phosphate units chainlength. More than 70% of the accumulation pool of polyphosphates was still in the cells after extraction. However, the electron microscopy study revealed that the native granular structure of polyphosphates had been destroyed by the hot water extraction procedure

  5. The influence of preoperative determinants on quality of life, functioning and pain after total knee and hip replacement: a pooled analysis of Dutch cohorts.

    Science.gov (United States)

    Hofstede, Stefanie N; Gademan, Maaike G J; Stijnen, Theo; Nelissen, Rob G H H; Marang-van de Mheen, Perla J

    2018-03-02

    Previous research has identified preoperative determinants that predict health related quality of life (HRQoL), functioning and pain after total knee or hip arthroplasty (TKA/THA), but these differed between studies and had opposite directions. This may be due to lack of power and not adjusting for confounders. The present study aims to identify the preoperative determinants that influence health related quality of life (HRQoL), functioning and pain after total knee or hip arthroplasty (TKA/THA). We pooled individual patient from 20 cohorts with OA patients data (n = 1783 TKA and n = 2400 THA) in the Netherlands. We examined the influence of age, gender, BMI and preoperative values of HRQoL, functioning and pain on postoperative status and total improvement. Linear mixed models were used to estimate the effect of each preoperative variable on a particular outcome for each cohort separately. These effects were pooled across cohorts using a random effects model. For each increase in preoperative point in HRQoL, the postoperative HRQoL increased by 0.51 points in TKA and 0.37 points in THA (SF-36 scale). Similarly, each point increase in preoperative functioning, resulted in a higher postoperative functioning of 0.31 (TKA) and 0.21 (THA) points (KOOS/HOOS-ADL scale). For pain this was 0.18 (TKA) and 0.15 (THA) points higher (KOOS/HOOS-pain scale) (higher means less pain). Even though patients with better preoperative values achieved better postoperative outcomes, their improvement was smaller. Women and patients with a higher BMI had more pain after a TKA and THA. Higher age and higher BMI was associated with lower postoperative HRQoL and functioning and more pain after a THA. Patients with a better preoperative health status have better outcomes, but less improvement. Even though the independent effects may seem small, combined results of preoperative variables may result in larger effects on postoperative outcomes.

  6. PDA: Pooled DNA analyzer

    Directory of Open Access Journals (Sweden)

    Lin Chin-Yu

    2006-04-01

    Full Text Available Abstract Background Association mapping using abundant single nucleotide polymorphisms is a powerful tool for identifying disease susceptibility genes for complex traits and exploring possible genetic diversity. Genotyping large numbers of SNPs individually is performed routinely but is cost prohibitive for large-scale genetic studies. DNA pooling is a reliable and cost-saving alternative genotyping method. However, no software has been developed for complete pooled-DNA analyses, including data standardization, allele frequency estimation, and single/multipoint DNA pooling association tests. This motivated the development of the software, 'PDA' (Pooled DNA Analyzer, to analyze pooled DNA data. Results We develop the software, PDA, for the analysis of pooled-DNA data. PDA is originally implemented with the MATLAB® language, but it can also be executed on a Windows system without installing the MATLAB®. PDA provides estimates of the coefficient of preferential amplification and allele frequency. PDA considers an extended single-point association test, which can compare allele frequencies between two DNA pools constructed under different experimental conditions. Moreover, PDA also provides novel chromosome-wide multipoint association tests based on p-value combinations and a sliding-window concept. This new multipoint testing procedure overcomes a computational bottleneck of conventional haplotype-oriented multipoint methods in DNA pooling analyses and can handle data sets having a large pool size and/or large numbers of polymorphic markers. All of the PDA functions are illustrated in the four bona fide examples. Conclusion PDA is simple to operate and does not require that users have a strong statistical background. The software is available at http://www.ibms.sinica.edu.tw/%7Ecsjfann/first%20flow/pda.htm.

  7. Lip and tooth injuries at public swimming pools in Austria.

    Science.gov (United States)

    Lechner, Katharina; Connert, Thomas; Kühl, Sebastian; Filippi, Andreas

    2017-06-01

    There is an increased risk of orofacial injuries in swimming pool facilities. Nevertheless, only a few studies have addressed this issue. The aim of this study was to identify the frequency of lip and tooth injuries at public swimming pools in Austria. A further aim was to examine which gender and age groups were affected, where and why these injuries occurred, and whether pool attendants had sufficient knowledge of dental first-aid measures. A total of 764 pool attendants in Austria were contacted by telephone and 689 participated in the study (90.2%). The attendants were interviewed retrospectively about accident occurrences in 2014 by a standardized questionnaire. Responses to the provision of first aid and choice of storage medium for avulsed teeth were subsequently evaluated. The frequency of lip injuries was 19.0%, and tooth injuries were 11.3%. Male bathers (P < .05) and children under 12 years (P < .001) most frequently suffered injuries. The waterslide was the most common accident site. The most common cause of lip injuries was slipping on wet surfaces (39.0%), and for tooth injuries it was collisions with other persons or objects (each 28.1%). The pool attendants' responses were predominantly good or sufficient on first aid, with the exception of what storage medium to choose. Tooth rescue boxes were available in only 8.6% of all pool facilities. Orofacial injuries are a frequently occurring problem in swimming pool facilities. The pool attendants' knowledge on first-aid care of tooth injuries could still be improved. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. 13 CFR 120.1706 - Pool Originator's retained interest in Pool.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Pool Originator's retained interest in Pool. 120.1706 Section 120.1706 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan...

  9. Vortex-induced buckling of a viscous drop impacting a pool

    KAUST Repository

    Li, Erqiang

    2017-07-20

    We study the intricate buckling patterns which can form when a viscous drop impacts a much lower viscosity miscible pool. The drop enters the pool by its impact inertia, flattens, and sinks by its own weight while stretching into a hemispheric bowl. Upward motion along the outer bottom surface of this bowl produces a vortical boundary layer which separates along its top and rolls up into a vortex ring. The vorticity is therefore produced in a fundamentally different way than for a drop impacting a pool of the same liquid. The vortex ring subsequently advects into the bowl, thereby stretching the drop liquid into ever thinner sheets, reaching the micron level. The rotating motion around the vortex pulls in folds to form multiple windings of double-walled toroidal viscous sheets. The axisymmetric velocity field thereby stretches the drop liquid into progressively finer sheets, which are susceptible to both axial and azimuthal compression-induced buckling. The azimuthal buckling of the sheets tends to occur on the inner side of the vortex ring, while their folds can be stretched and straightened on the outside edge. We characterize the total stretching from high-speed video imaging and use particle image velocimetry to track the formation and evolution of the vortex ring. The total interfacial area between the drop and the pool liquid can grow over 40-fold during the first 50 ms after impact. Increasing pool viscosity shows entrapment of a large bubble on top of the drop, while lowering the drop viscosity produces intricate buckled shapes, appearing at the earliest stage and being promoted by the crater motions. We also present an image collage of the most intriguing and convoluted structures observed. Finally, a simple point-vortex model reproduces some features from the experiments and shows variable stretching along the wrapping sheets.

  10. Reracking Possibilities of the NPP Krsko Spent Fuel Pool

    International Nuclear Information System (INIS)

    Bace, M.; Pevec, D.; Smuc, T.

    1998-01-01

    Using the SCALE-4 code package reracking possibilities of the NPP Krsko spent fuel pool were analyzed. Two cases were considered: the first case assuming the 40 years lifetime of the plant, and the second case assuming the 50 years lifetime of the plant. It was shown that it is possible to design the additional racks in free space of the spent fuel pool with the sufficient total capacity to store all the spent fuel generated during the 40 years lifetime of the plant. In the case of 50 years plant lifetime, completely new racks (capacity of 1890 spent fuel assemblies), containing 4mm boral in storage cell walls, were proposed for the NPP Krsko spent fuel pool. The effective multiplication factor of the spent fuel pool fully loaded with new racks containing spent fuel assemblies of initial enrichment 4.3 w/o, burned to 40 GWd/tU and cooled 2 years is lower than the value required by standard. It showed the possibility of the safe disposal of all spent fuel accumulated during more than 50 years lifetime of the plant. (author)

  11. Distribution and elevated soil pools of mercury in an acidic subtropical forest of southwestern China

    International Nuclear Information System (INIS)

    Zhou, Jun; Wang, Zhangwei; Zhang, Xiaoshan; Chen, Jian

    2015-01-01

    Tieshanping catchment in southwest China was supposed to a large pool of atmospheric mercury. This work was aimed to examine THg (total mercury) concentrations, pools and influence factors in the acidic forest. THg concentrations were highly elevated in the study area, which was significantly depended on TOM (total organic matter) concentrations and altitudinal elevation, whereas negatively correlated with soil pH. The pools of mercury accumulated in soils were correlated strongly with the stocks of TOM and altitude, ranged from 5.9 to 32 mg m −2 and averaged 14.5 mg m −2 , indicating that the acidic forest was a great sink of atmospheric mercury in southwest China. THg concentrations in stream waters decreased with altitude increasing and regression analyses showed that soil/air exchange flux would be increased with the decrease of altitude. Present results suggest that elevation increasing decreases THg losses as low THg concentrations in runoffs and volatilization from soils. - Highlights: • Soil THg pools and influence factors were studied at an acidic catchment in southwestern China. • THg concentrations was increased significantly with TOM concentrations and altitude increasing, decreased with pH. • THg pools in soils were highly elevated and deepened on TOM pools and altitude. • Difference in THg output by volatilization and runoff was a major reason for THg distribution at different altitudes. - Mercury pools increased with altitude increasing as mercury lost more at low elevation area in acidic subtropical forest

  12. Applications of pooled DNA samples to the assessment of population affinities: short tandem repeats.

    Science.gov (United States)

    Crawford, M H; Banerjee, P; Demarchi, D A; Zlojutro, M; McComb, J; Livshits, G; Henneberg, M; Mosher, M J; Schanfield, M S; Knowles, J A

    2005-12-01

    Pooled DNA samples have been used in association studies of Mendelian disease genes. This method involves combining equal quantities of DNA from patients and control subjects into separate pools and comparing the pools for distributions of genetic markers. In this study identical quantities of DNA from 300 individuals representing 6 populations were pooled and amplified for 296 loci using the touchdown polymerase chain reaction (PCR) method. The purpose of this study is to test the efficacy of pooled DNA markers in the reconstruction of the genetic structure of human populations. The populations sampled included Chuvash, Buryats, Kizhi, Native Americans, South Africans, and New York City whites. To test the accuracy of the allele-frequency distributions, we genotyped the Buryats and New York samples individually for six microsatellite markers and compared their frequencies to the allele frequencies derived from the electropherogram peak heights for the pooled DNA, producing a correlation of 0.9811 with a variance of less than 0.04. Two-dimensional scaling of genetic distances among the six populations produced clusters that reflected known historical relationships. A distance matrix was created using all 296 loci, and matrices based on individual chromosomes were correlated against the total matrix. As expected, the largest chromosomes had the highest correlations with the total matrix, whereas one of the smallest chromosomes, chromosome 22, had the lowest correlation and differed most from the combined STR distance matrix.

  13. Big city consultants shut down our pool : a shocking community pool gets checked for stray voltage

    Energy Technology Data Exchange (ETDEWEB)

    Lynch, P. [Power Line Systems Engineering Inc., Markham, ON (Canada)

    2009-12-15

    This article discussed an investigation conducted at a community pool where swimmers complained of receiving electrical shocks both in the pool and on the pool's deck area. Electrical measurements taken at the pool revealed current flows from the pool water to various points around the deck area. Measured current flow in the pool area was 30 amps even when the main pool service breaker was opened to shut off power to the entire facility. Thirty amps of primary neutral current was then measured on the primary side aerial neutral in front of the pool. A 10 amp primary feeder from the pool joined up with the complex's primary neutral wire to increase the neutral current to 40 amps. The combined 40 amps current then returned to the secondary side of a nearby utility transformer substation. The study showed that the underground wet low-resistance grounded surface area of the pool was attracting the 30 amps of utility current from the surrounding ground area. The local utility disconnected the primary and secondary neutral interconnection at the pool's main 600-volt step-down transformer. The pool deck was removed in order to install additional copper bonding grounds. In order to avert serious injuries, many experts propose that all electric utilities should be required by law to reconfigure their power systems to prevent primary power neutral currents from entering private buildings. 1 tab., 2 figs.

  14. Survey of bacterial contamination of environment of swimming pools in Yazd city, in 2013

    Directory of Open Access Journals (Sweden)

    Hossein Jafari Mansoorian

    2015-09-01

    Full Text Available Background: Infections are readily transmitted as a result of bacterial contamination of swimming pools. Therefore, hygiene and preventing the contamination of swimming pools is of particular importance. The objective of this study was to determine the amount of bacterial contamination in indoor pools of Yazd in 2013. Methods: In this descriptive and analytical study, all indoor swimming pools of Yazd (12 pools were evaluated during the spring and summer of 2013, in terms of bacterial contamination. In order to determine contamination, a sterile cotton swab was used for sampling. On average, 45 samples were taken from different surfaces in each pool (shower, dressing room, sitting places in sauna, platforms and around the pool. In total, about 540 samples from all pools were tested for bacterial contamination. Results: The results show that from 540 samples, bacterial contamination was observed in about 93 samples (17.22%; and was seen more in showers, edges of the pool and jacuzzis, and the slippers used in swimming pools. The most important isolated bacteria types were E. coli, Actinobacteria, Pseudomonas alcaligenes, Pseudomonas aeruginosa and Klebsiella pneumonia. Conclusion: The results indicate the presence of bacterial contamination on the surface of these places. It is recommended that health authorities should pay more attention to cleaning and disinfecting surfaces around the pool, showers, dressing rooms etc, to prevent infectious disease transfer as a result of contact with contaminated swimming pool surfaces.

  15. Mercury concentrations and pools in four adjacent coniferous and deciduous upland forests in Beijing, China

    Science.gov (United States)

    Zhou, Jun; Wang, Zhangwei; Zhang, Xiaoshan; Gao, Yu

    2017-05-01

    Understanding of forest mercury (Hg) pools is important for quantifying the global atmospheric Hg removal. We studied gaseous elemental Hg (GEM) concentrations, litterfall Hg depositions, and pool sizes in four adjacent stands at Mount Dongling to assess Hg dynamics in the forested catchment and the potential of Hg release during wildfires. The average GEM concentration was 2.5 ± 0.5 ng m-3, about 1.5 times of the background levels in the Northern Hemisphere. In all four stands, Hg concentrations increase in the following order: bole wood mineral soil litter < Oe soil < Oa organic soil. The Hg pools of aboveground biomass were comparable in the forests of larch, oak, and Chinese pine, which were much greater than that of mixed broadleaf stands due to lower biomass. The total Hg pools in ecosystems were similar in the four stands, because of the comparable Hg pool in the soil horizons (0-40 cm), which accounted for over 97% of the total ecosystem Hg storage in the four stands. Although Hg pools of the forest ecosystem in north China were comparable to North America and North Europe, Hg storage in forests constituted a high threat for large Hg emission pulses to the atmosphere by wildfires. The potential Hg emissions from the combustion at the four stands were ranged from 0.675 to 1.696 mg m-2.

  16. poolHiTS: A Shifted Transversal Design based pooling strategy for high-throughput drug screening

    Directory of Open Access Journals (Sweden)

    Woolf Peter J

    2008-05-01

    Full Text Available Abstract Background A key goal of drug discovery is to increase the throughput of small molecule screens without sacrificing screening accuracy. High-throughput screening (HTS in drug discovery involves testing a large number of compounds in a biological assay to identify active compounds. Normally, molecules from a large compound library are tested individually to identify the activity of each molecule. Usually a small number of compounds are found to be active, however the presence of false positive and negative testing errors suggests that this one-drug one-assay screening strategy can be significantly improved. Pooling designs are testing schemes that test mixtures of compounds in each assay, thereby generating a screen of the whole compound library in fewer tests. By repeatedly testing compounds in different combinations, pooling designs also allow for error-correction. These pooled designs, for specific experiment parameters, can be simply and efficiently created using the Shifted Transversal Design (STD pooling algorithm. However, drug screening contains a number of key constraints that require specific modifications if this pooling approach is to be useful for practical screen designs. Results In this paper, we introduce a pooling strategy called poolHiTS (Pooled High-Throughput Screening which is based on the STD algorithm. In poolHiTS, we implement a limit on the number of compounds that can be mixed in a single assay. In addition, we show that the STD-based pooling strategy is limited in the error-correction that it can achieve. Due to the mixing constraint, we show that it is more efficient to split a large library into smaller blocks of compounds, which are then tested using an optimized strategy repeated for each block. We package the optimal block selection algorithm into poolHiTS. The MATLAB codes for the poolHiTS algorithm and the corresponding decoding strategy are also provided. Conclusion We have produced a practical version

  17. Convective cooling in a pool-type research reactor

    Science.gov (United States)

    Sipaun, Susan; Usman, Shoaib

    2016-01-01

    A reactor produces heat arising from fission reactions in the nuclear core. In the Missouri University of Science and Technology research reactor (MSTR), this heat is removed by natural convection where the coolant/moderator is demineralised water. Heat energy is transferred from the core into the coolant, and the heated water eventually evaporates from the open pool surface. A secondary cooling system was installed to actively remove excess heat arising from prolonged reactor operations. The nuclear core consists of uranium silicide aluminium dispersion fuel (U3Si2Al) in the form of rectangular plates. Gaps between the plates allow coolant to pass through and carry away heat. A study was carried out to map out heat flow as well as to predict the system's performance via STAR-CCM+ simulation. The core was approximated as porous media with porosity of 0.7027. The reactor is rated 200kW and total heat density is approximately 1.07+E7 Wm-3. An MSTR model consisting of 20% of MSTR's nuclear core in a third of the reactor pool was developed. At 35% pump capacity, the simulation results for the MSTR model showed that water is drawn out of the pool at a rate 1.28 kg s-1 from the 4" pipe, and predicted pool surface temperature not exceeding 30°C.

  18. Carbon dynamics in peatland pool systems: the role of light

    Science.gov (United States)

    Pickard, Amy; Heal, Kate; McLeod, Andy; Dinsmore, Kerry

    2016-04-01

    Open-water pools are widespread in peatlands and are considered to represent biogeochemical hotspots within the peatland landscape. However the contribution of pool systems to wider peatland C cycling has not been quantified fully and there is a lack of knowledge of the role of photochemical processes in such environments. In this study, light exposure experiments were conducted in two contrasting pools to test the reactivity of aquatic C. The first study site was located at Cross Lochs (CL), Forsinard, in the Flow Country of Northern Scotland, in a 412 m2 pool characterised by low dissolved organic carbon (DOC) concentrations (˜15 mg C L-1). The second site was located at Red Moss of Balerno (RM), a raised bog in central Scotland, in a 48 m2 pool with high DOC concentrations (˜35 mg C L-1). Experiments took place over 9 days in situ at each pool in mid-summer 2015, with 500 mL water samples contained in bags transparent to sunlight and in opaque control bags. After field exposure, optical, chemical and stable C isotope analyses were conducted on the samples. Significant differences in biogeochemical cycling of DOC were detected between the two systems, with DOC losses as a percentage of the total C pool 15% higher at RM than at CL after light exposure. The mean DOC concentration of light exposed samples at RM declined steeply initially, with 83% observed DOC degradation occurring by day 3 of the experiment. Total losses of 7.9 mg DOC L-1were observed in light exposed samples at RM, along with decreasing E4:E6 ratios, suggesting that material remaining at the end of the experiment was humified. Depletion of DOC was positively correlated with production of CO2 at both sites, with concentrations of up to 4.3 mg CO2-C L-1 recorded at RM. Stable C isotope signatures at both sites were altered under light treatment, as demonstrated by the production of enriched δ13C-DOC (+0.46 ‰ relative to opaque bags) and depleted δ13C-DIC (-0.97 ‰ relative to opaque bags) at

  19. Research program on the feasibility of pool type LMFBR in Japan

    International Nuclear Information System (INIS)

    Hattori, Sadao

    1982-01-01

    The Central Research Institute of Electric Power Industry has started the feasibility study to evaluate the possiblity of existence of large pool type FBR plants in Japan as the three-year project from fiscal 1981. The development of FBRs is indispensable for the effective use of nuclear fuel and the establishment of energy security. The knowledge on the characteristics of FBR core, sodium technology and others has advanced rapidly in Japan. At the stage of the practical reactors with large capacity, the pool type is naturally considered as the object of selection, but the aseismatic capability and safety of the large containment vessels for the pool type and the qualitative and quantitative acceptability of the research and development for the pool type are the problems. The difference between the loop type and the pool type is only the structural change arising from the difference in the arrangement of equipment. The pool type reactors have been operated already in the UK and France. The objective of the research and main subjects, the total plan and research organization, the fundamental condition of investigation, the research procedure for respective subjects, and the outline of model test are discribed. The change of design and safety standards in the future must be predicted and taken in consideration in the research. (Kako, I.)

  20. Pool scrubbing

    International Nuclear Information System (INIS)

    Lopez-Jimenez, J.; Herranz, J.; Escudero, M.J.; Espigares, M.M.; Peyres, V.; Polo, J.; Kortz, Ch.; Koch, M.K.; Brockmeier, U.; Unger, H.; Dutton, L.M.C.; Smedley, Ch.; Trow, W.; Jones, A.V.; Bonanni, E.; Calvo, M.; Alonso, A.

    1996-12-01

    The Source Term Project in the Third Frame Work Programme of the European Union Was conducted under and important joined effort on pool scrubbing research. CIEMAT was the Task Manager of the project and several other organizations participated in it: JRC-Ispra, NNC Limited, RUB-NES and UPM. The project was divided into several tasks. A peer review of the models in the pool scrubbing codes SPARC90 and BUSCA-AUG92 was made, considering the different aspects in the hydrodynamic phenomenology, particle retention and fission product vapor abortions. Several dominant risk accident sequences were analyzed with MAAP, SPARC90 and BUSCA-AUG92 codes, and the predictions were compared. A churn-turbulent model was developed for the hydrodynamic behaviour of the pool. Finally, an experimental programme in the PECA facility of CIEMAT was conducted in order to study the decontamination factor under jet injection regime, and the experimental observations were compared with the SPARC and BUSCA codes. (Author)

  1. Bermudagrass Management in the Southern Piedmont U.S. IV. Soil Surface Nitrogen Pools

    Directory of Open Access Journals (Sweden)

    Alan J. Franzluebbers

    2001-01-01

    Full Text Available The fate of nitrogen (N applied in forage-based agricultural systems is important for understanding the long-term production and environmental impacts of a particular management strategy. We evaluated the factorial combination of three types of N fertilization (inorganic, crimson clover [Trifolium incarnatum L.] cover crop plus inorganic, and chicken [Gallus gallus] broiler litter pressure and four types of harvest strategy (unharvested forage, low and high cattle [Bos Taurus] grazing pressure, and monthly haying in summer on surface residue and soil N pools during the first 5 years of ̒Coastal̓ bermudagrass (Cynodon dactylon [L.] Pers. management. The type of N fertilization used resulted in small changes in soil N pools, except at a depth of 0 to 2 cm, where total soil N was sequestered at a rate 0.2 g ‧ kg–1‧ year–11 greater with inorganic fertilization than with other fertilization strategies. We could account for more of the applied N under grazed systems (76–82% than under ungrazed systems (35–71%. As a percentage of applied N, 32 and 48% were sequestered as total soil N at a depth of 0 to 6 cm when averaged across fertilization strategies under low and high grazing pressures, respectively, which was equivalent to 6.8 and 10.3 g ‧ m–2 ‧ year–1. Sequestration rates of total soil N under the unharvested-forage and haying strategies were negligible. Most of the increase in total soil N was at a depth of 0 to 2 cm and was due to changes in the particulate organic N (PON pool. The greater cycling of applied N into the soil organic N pool with grazed compared with ungrazed systems suggests an increase in the long-term fertility of soil.

  2. Decommissioning the Dresden Unit 1 Spent Fuel Pool

    International Nuclear Information System (INIS)

    Demmer, R.L.; Bargelt, R.J.; Panozzo, J.B.; Christensen, R.J.

    2006-01-01

    The Dresden Nuclear Power Station, Unit 1 Spent Fuel Pool (SFP) (Exelon Generation Co.) was decommissioned using a new underwater coating strategy developed in cooperation with the Idaho National Laboratory (INL). This was the first time that a commercial nuclear power plant (NPP) SFP was decommissioned using this underwater coating approach. This approach has advantages in many aspects, particularly in reducing airborne contamination and in safer, more cost effective deactivation. The process was pioneered at the INL and used to decommission three SFPs with a total combined pool volume of over 900,000 gallons. The INL provided engineering support and shared project plans to successfully initiate the Dresden project. This report outlines the steps taken by the INL and Exelon on the pathway for this activity. The rationale used to select the underwater coating option and the advantages and disadvantages are shown. Special circumstances, such as the use of a remotely operated underwater vehicle to map (visually and radiologically) the pool areas that were not readily accessible, are discussed. Several specific areas where special equipment was employed are given and a lessons learned evaluation is included. (authors)

  3. Convective cooling in a pool-type research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sipaun, Susan, E-mail: susan@nm.gov.my [Malaysian Nuclear Agency, Industrial Technology Division, Blok 29T, Bangi 43200, Selangor (Malaysia); Usman, Shoaib, E-mail: usmans@mst.edu [Missouri University of Science and Technology, Nuclear Engineering, 222 Fulton Hall 301 W.14th St., Rolla 64509 MO (United States)

    2016-01-22

    A reactor produces heat arising from fission reactions in the nuclear core. In the Missouri University of Science and Technology research reactor (MSTR), this heat is removed by natural convection where the coolant/moderator is demineralised water. Heat energy is transferred from the core into the coolant, and the heated water eventually evaporates from the open pool surface. A secondary cooling system was installed to actively remove excess heat arising from prolonged reactor operations. The nuclear core consists of uranium silicide aluminium dispersion fuel (U{sub 3}Si{sub 2}Al) in the form of rectangular plates. Gaps between the plates allow coolant to pass through and carry away heat. A study was carried out to map out heat flow as well as to predict the system’s performance via STAR-CCM+ simulation. The core was approximated as porous media with porosity of 0.7027. The reactor is rated 200kW and total heat density is approximately 1.07+E7 Wm{sup −3}. An MSTR model consisting of 20% of MSTR’s nuclear core in a third of the reactor pool was developed. At 35% pump capacity, the simulation results for the MSTR model showed that water is drawn out of the pool at a rate 1.28 kg s{sup −1} from the 4” pipe, and predicted pool surface temperature not exceeding 30°C.

  4. Design of hydrotherapy exercise pools.

    Science.gov (United States)

    Edlich, R F; Abidin, M R; Becker, D G; Pavlovich, L J; Dang, M T

    1988-01-01

    Several hydrotherapy pools have been designed specifically for a variety of aquatic exercise. Aqua-Ark positions the exerciser in the center of the pool for deep-water exercise. Aqua-Trex is a shallow underwater treadmill system for water walking or jogging. Swim-Ex generates an adjustable laminar flow that permits swimming without turning. Musculoskeletal conditioning can be accomplished in the above-ground Arjo shallow-water exercise pool. A hydrotherapy pool also can be custom designed for musculoskeletal conditioning in its shallow part and cardiovascular conditioning in a deeper portion of the pool. Regardless of the type of exercise, there is general agreement that the specific exercise conducted in water requires significantly more energy expenditure than when the same exercise is performed on land.

  5. Swimming pool cleaner poisoning

    Science.gov (United States)

    Swimming pool cleaner poisoning occurs when someone swallows this type of cleaner, touches it, or breathes in ... The harmful substances in swimming pool cleaner are: Bromine ... copper Chlorine Soda ash Sodium bicarbonate Various mild acids

  6. Screening and ranking Alberta oil pools for CO{sub 2} flooding and sequestration

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, J.C. [Adams Pearson Associates Inc., Calgary, AB (Canada); Bachu, S. [Alberta Energy and Utilities Board, Calgary, AB (Canada)

    2001-06-01

    This paper presented the results of a technical screening program using Excel VBA to successfully screen and rank a very large number of oil pools for enhanced oil recovery using carbon dioxide (CO{sub 2}) flooding. A total of 6 ranking parameters were used, including API gravity of oil, residual oil saturation, ratio between reservoir pressure and minimum miscibility pressure, reservoir temperature, net pay thickness and porosity. The screening program provided a technical ranking of approximately 8,800 Alberta pools in less than 2 minutes. After compilation of the Alberta oil pools, it was determined that most of the deep carbonate oil pools are excellent candidates for CO{sub 2} miscible flooding. Other Devonian carbonate pools were also ranked as having high potential for the process. An environmental benefit of CO{sub 2} miscible flooding process is that carbon sequestration has the potential to reduce anthropogenic carbon dioxide emissions from reaching the atmosphere. Ongoing studies are currently addressing CO{sub 2} capture and transportation, making EOR technology viable for maintaining light oil production in western Canada. 11 refs., 7 tabs., 1 fig.

  7. Efficient pooling designs for library screening

    OpenAIRE

    Bruno, William J.; Knill, Emanuel; Balding, David J.; Bruce, D. C.; Doggett, N. A.; Sawhill, W. W.; Stallings, R. L.; Whittaker, Craig C.; Torney, David C.

    1994-01-01

    We describe efficient methods for screening clone libraries, based on pooling schemes which we call ``random $k$-sets designs''. In these designs, the pools in which any clone occurs are equally likely to be any possible selection of $k$ from the $v$ pools. The values of $k$ and $v$ can be chosen to optimize desirable properties. Random $k$-sets designs have substantial advantages over alternative pooling schemes: they are efficient, flexible, easy to specify, require fewer pools, and have er...

  8. 21 CFR 1250.89 - Swimming pools.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Swimming pools. 1250.89 Section 1250.89 Food and... SANITATION Sanitation Facilities and Conditions on Vessels § 1250.89 Swimming pools. (a) Fill and draw swimming pools shall not be installed or used. (b) Swimming pools of the recirculation type shall be...

  9. Modal analysis of pool door in water tank

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Soo; Jeong, Kyeong Hoon; Park, Chan Gook; Koo, In Soo [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    A pool door is installed at the chase of the pool gate by means of an overhead crane in the building of a research reactor. The principal function of the pool door, which is located between the reactor pool and service pool, is to separate the reactor pool from the service pool for the maintenance and/or the removal of the equipment either in the reactor pool or service pool. The pool door consists of stainless steel plates supported by structural steel frames and sealing components. The pool door is equipped with double inflatable gaskets. The configuration of the pool door is shown in Figure 1. The FEM analysis and theoretical calculation by the formula were performed to evaluate the natural frequency for the pool door in the water. The results from the two methods were compared.

  10. Titanium distribution in swimming pool water is dominated by dissolved species.

    Science.gov (United States)

    David Holbrook, R; Motabar, Donna; Quiñones, Oscar; Stanford, Benjamin; Vanderford, Brett; Moss, Donna

    2013-10-01

    The increased use of titanium dioxide nanoparticles (nano-TiO2) in consumer products such as sunscreen has raised concerns about their possible risk to human and environmental health. In this work, we report the occurrence, size fractionation and behavior of titanium (Ti) in a children's swimming pool. Size-fractionated samples were analyzed for Ti using ICP-MS. Total titanium concentrations ([Ti]) in the pool water ranged between 21 μg/L and 60 μg/L and increased throughout the 101-day sampling period while [Ti] in tap water remained relatively constant. The majority of [Ti] was found in the dissolved phase (microparticulate. Simple models suggest that evaporation may account for the observed variation in [Ti], while sunscreen may be a relevant source of particulate and microparticule Ti. Compared to diet, incidental ingestion of nano-Ti from swimming pool water is minimal. Published by Elsevier Ltd.

  11. Determination of total ribonucleotide pool in plant materials by high-pH anion-exchange high-performance liquid chromatography following extraction with potassium hydroxide.

    Science.gov (United States)

    Riondet, Christophe; Morel, Sylvain; Alcaraz, Gérard

    2005-06-10

    A new, improved method that only requires a potassium hydroxide extraction procedure is presented for the analysis of a full nucleotide pool in plant materials. Quantification was performed by high-pH anion-exchange chromatography (HPAEC) with UV detection after a potassium hydroxide extraction, and allowed the quantification of 13 linear ribonucleotides in a single run. The method has been validated by comparison of six extraction methods and also by measurement of the intracellular nucleotide levels of three plant species (cell cultures and leaves). The evolution of the nucleotide pool of Nicotiana tabacum cell culture during growth has also been measured, and showed an increase in the pool until the fifth day, where the growth rate reaches a maximum, after which a decrease was observed.

  12. Numerical modeling of sodium fire – Part II: Pool combustion and combined spray and pool combustion

    International Nuclear Information System (INIS)

    Sathiah, Pratap; Roelofs, Ferry

    2014-01-01

    Highlights: • A CFD based method is proposed for the simulation of sodium pool combustion. • A sodium evaporation based model is proposed to model sodium pool evaporation. • The proposed method is validated against sodium pool experiments of Newman and Payne. • The results obtained using the proposed method are in good agreement with the experiments. - Abstract: The risk of sodium-air reaction has received considerable attention after the sodium-fire accident in Monju reactor. The fires resulting from the sodium-air reaction can be detrimental to the safety of a sodium fast reactor. Therefore, predicting the consequences of a sodium fire is important from a safety point of view. A computational method based on CFD is proposed here to simulate sodium pool fire and understand its characteristics. The method solves the Favre-averaged Navier-Stokes equation and uses a non-premixed mixture fraction based combustion model. The mass transfer of sodium vapor from the pool surface to the flame is obtained using a sodium evaporation model. The proposed method is then validated against well-known sodium pool experiments of Newman and Payne. The flame temperature and location predicted by the model are in good agreement with experiments. Furthermore, the trends of the mean burning rate with initial pool temperature and oxygen concentration are captured well. Additionally, parametric studies have been performed to understand the effects of pool diameter and initial air temperature on the mean burning rate. Furthermore, the sodium spray and sodium pool combustion models are combined to simulate simultaneous spray and pool combustion. Simulations were performed to demonstrate that the combined code could be applied to simulate this. Once sufficiently validated, the present code can be used for safety evaluation of a sodium fast reactor

  13. Numerical modeling of sodium fire – Part II: Pool combustion and combined spray and pool combustion

    Energy Technology Data Exchange (ETDEWEB)

    Sathiah, Pratap, E-mail: pratap.sathiah78@gmail.com [Shell Global Solutions Ltd., Brabazon House, Concord Business Park, Threapwood Road, Manchester M220RR (United Kingdom); Roelofs, Ferry, E-mail: roelofs@nrg.eu [Nuclear Research and Consultancy Group (NRG), Westerduinweg 3, 1755ZG Petten (Netherlands)

    2014-10-15

    Highlights: • A CFD based method is proposed for the simulation of sodium pool combustion. • A sodium evaporation based model is proposed to model sodium pool evaporation. • The proposed method is validated against sodium pool experiments of Newman and Payne. • The results obtained using the proposed method are in good agreement with the experiments. - Abstract: The risk of sodium-air reaction has received considerable attention after the sodium-fire accident in Monju reactor. The fires resulting from the sodium-air reaction can be detrimental to the safety of a sodium fast reactor. Therefore, predicting the consequences of a sodium fire is important from a safety point of view. A computational method based on CFD is proposed here to simulate sodium pool fire and understand its characteristics. The method solves the Favre-averaged Navier-Stokes equation and uses a non-premixed mixture fraction based combustion model. The mass transfer of sodium vapor from the pool surface to the flame is obtained using a sodium evaporation model. The proposed method is then validated against well-known sodium pool experiments of Newman and Payne. The flame temperature and location predicted by the model are in good agreement with experiments. Furthermore, the trends of the mean burning rate with initial pool temperature and oxygen concentration are captured well. Additionally, parametric studies have been performed to understand the effects of pool diameter and initial air temperature on the mean burning rate. Furthermore, the sodium spray and sodium pool combustion models are combined to simulate simultaneous spray and pool combustion. Simulations were performed to demonstrate that the combined code could be applied to simulate this. Once sufficiently validated, the present code can be used for safety evaluation of a sodium fast reactor.

  14. 10 CFR 36.63 - Pool water purity.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Pool water purity. 36.63 Section 36.63 Energy NUCLEAR... § 36.63 Pool water purity. (a) Pool water purification system must be run sufficiently to maintain the conductivity of the pool water below 20 microsiemens per centimeter under normal circumstances. If pool water...

  15. Pooling, meta-analysis, and the evaluation of drug safety

    Directory of Open Access Journals (Sweden)

    Leizorovicz Alain

    2002-03-01

    Full Text Available Abstract Background The "integrated safety report" of the drug registration files submitted to health authorities usually summarizes the rates of adverse events observed for a new drug, placebo or active control drugs by pooling the safety data across the trials. Pooling consists of adding the numbers of events observed in a given treatment group across the trials and dividing the results by the total number of patients included in this group. Because it considers treatment groups rather than studies, pooling ignores validity of the comparisons and is subject to a particular kind of bias, termed "Simpson's paradox." In contrast, meta-analysis and other stratified analyses are less susceptible to bias. Methods We use a hypothetical, but not atypical, application to demonstrate that the results of a meta-analysis can differ greatly from those obtained by pooling the same data. In our hypothetical model, a new drug is compared to 1 a placebo in 4 relatively small trials in patients at high risk for a certain adverse event and 2 an active reference drug in 2 larger trials of patients at low risk for this event. Results Using meta-analysis, the relative risk of experiencing the adverse event with the new drug was 1.78 (95% confidence interval [1.02; 3.12] compared to placebo and 2.20 [0.76; 6.32] compared to active control. By pooling the data, the results were, respectively, 1.00 [0.59; 1.70] and 5.20 [2.07; 13.08]. Conclusions Because these findings could mislead health authorities and doctors, regulatory agencies should require meta-analyses or stratified analyses of safety data in drug registration files.

  16. Model of large pool fires

    Energy Technology Data Exchange (ETDEWEB)

    Fay, J.A. [Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)]. E-mail: jfay@mit.edu

    2006-08-21

    A two zone entrainment model of pool fires is proposed to depict the fluid flow and flame properties of the fire. Consisting of combustion and plume zones, it provides a consistent scheme for developing non-dimensional scaling parameters for correlating and extrapolating pool fire visible flame length, flame tilt, surface emissive power, and fuel evaporation rate. The model is extended to include grey gas thermal radiation from soot particles in the flame zone, accounting for emission and absorption in both optically thin and thick regions. A model of convective heat transfer from the combustion zone to the liquid fuel pool, and from a water substrate to cryogenic fuel pools spreading on water, provides evaporation rates for both adiabatic and non-adiabatic fires. The model is tested against field measurements of large scale pool fires, principally of LNG, and is generally in agreement with experimental values of all variables.

  17. Model of large pool fires

    International Nuclear Information System (INIS)

    Fay, J.A.

    2006-01-01

    A two zone entrainment model of pool fires is proposed to depict the fluid flow and flame properties of the fire. Consisting of combustion and plume zones, it provides a consistent scheme for developing non-dimensional scaling parameters for correlating and extrapolating pool fire visible flame length, flame tilt, surface emissive power, and fuel evaporation rate. The model is extended to include grey gas thermal radiation from soot particles in the flame zone, accounting for emission and absorption in both optically thin and thick regions. A model of convective heat transfer from the combustion zone to the liquid fuel pool, and from a water substrate to cryogenic fuel pools spreading on water, provides evaporation rates for both adiabatic and non-adiabatic fires. The model is tested against field measurements of large scale pool fires, principally of LNG, and is generally in agreement with experimental values of all variables

  18. POOL WATER TREATMENT AND COOLING SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    King, V.

    2000-01-01

    The Pool Water Treatment and Cooling System is located in the Waste Handling Building (WHB), and is comprised of various process subsystems designed to support waste handling operations. This system maintains the pool water temperature within an acceptable range, maintains water quality standards that support remote underwater operations and prevent corrosion, detects leakage from the pool liner, provides the capability to remove debris from the pool, controls the pool water level, and helps limit radiological exposure to personnel. The pool structure and liner, pool lighting, and the fuel staging racks in the pool are not within the scope of the Pool Water Treatment and Cooling System. Pool water temperature control is accomplished by circulating the pool water through heat exchangers. Adequate circulation and mixing of the pool water is provided to prevent localized thermal hotspots in the pool. Treatment of the pool water is accomplished by a water treatment system that circulates the pool water through filters, and ion exchange units. These water treatment units remove radioactive and non-radioactive particulate and dissolved solids from the water, thereby providing the water clarity needed to conduct waste handling operations. The system also controls pool water chemistry to prevent advanced corrosion of the pool liner, pool components, and fuel assemblies. Removal of radioactivity from the pool water contributes to the project ALARA (as low as is reasonably achievable) goals. A leak detection system is provided to detect and alarm leaks through the pool liner. The pool level control system monitors the water level to ensure that the minimum water level required for adequate radiological shielding is maintained. Through interface with a demineralized water system, adequate makeup is provided to compensate for loss of water inventory through evaporation and waste handling operations. Interface with the Site Radiological Monitoring System provides continuous

  19. Analysis of an open-air swimming pool solar heating system by using an experimentally validated TRNSYS model

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, Elisa; Martinez, Pedro J. [Universidad Miguel Hernandez - Edificio Torreblanca, Avda. de la Universidad s/n, 03202 Elche (Spain)

    2010-01-15

    In the case of private outdoor swimming pools, seldom larger than 100 m{sup 2}, conventional auxiliary heating systems are being installed less and less. Solar heating is an option to extend the swimming season. The temperature evolution of an open-air swimming pool highly depends on the wind speed directly on the water surface, which at the same time is influenced by the surroundings of the pool. In this paper, the TRNSYS model of a private open-air pool with a 50-m{sup 2} surface was validated by registering the water temperature evolution and the meteorological data at the pool site. Evaporation is the main component of energy loss in swimming pools. Six different sets of constants found in literature were considered to evaluate the evaporative heat transfer coefficient with the purpose of finding the most suitable one for the TRNSYS pool model. In order to do that, the evolution of the pool water temperature predicted by the TRNSYS pool model was compared with the experimentally registered one. The simulation with TRNSYS of the total system, including the swimming pool and the absorber circuit integrated into the existing filter circuit, provided information regarding the increase of the pool temperature for different collector areas during the swimming season. This knowledge, together with the economic costs, support the decision about the absorber field size. (author)

  20. Pool scrubbing models for iodine components

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, K [Battelle Ingenieurtechnik GmbH, Eschborn (Germany)

    1996-12-01

    Pool scrubbing is an important mechanism to retain radioactive fission products from being carried into the containment atmosphere or into the secondary piping system. A number of models and computer codes has been developed to predict the retention of aerosols and fission product vapours that are released from the core and injected into water pools of BWR and PWR type reactors during severe accidents. Important codes in this field are BUSCA, SPARC and SUPRA. The present paper summarizes the models for scrubbing of gaseous Iodine components in these codes, discusses the experimental validation, and gives an assessment of the state of knowledge reached and the open questions which persist. The retention of gaseous Iodine components is modelled by the various codes in a very heterogeneous manner. Differences show up in the chemical species considered, the treatment of mass transfer boundary layers on the gaseous and liquid sides, the gas-liquid interface geometry, calculation of equilibrium concentrations and numerical procedures. Especially important is the determination of the pool water pH value. This value is affected by basic aerosols deposited in the water, e.g. Cesium and Rubidium compounds. A consistent model requires a mass balance of these compounds in the pool, thus effectively coupling the pool scrubbing phenomena of aerosols and gaseous Iodine species. Since the water pool conditions are also affected by drainage flow of condensate water from different regions in the containment, and desorption of dissolved gases on the pool surface is determined by the gas concentrations above the pool, some basic limitations of specialized pool scrubbing codes are given. The paper draws conclusions about the necessity of coupling between containment thermal-hydraulics and pool scrubbing models, and proposes ways of further simulation model development in order to improve source term predictions. (author) 2 tabs., refs.

  1. Pool scrubbing models for iodine components

    International Nuclear Information System (INIS)

    Fischer, K.

    1996-01-01

    Pool scrubbing is an important mechanism to retain radioactive fission products from being carried into the containment atmosphere or into the secondary piping system. A number of models and computer codes has been developed to predict the retention of aerosols and fission product vapours that are released from the core and injected into water pools of BWR and PWR type reactors during severe accidents. Important codes in this field are BUSCA, SPARC and SUPRA. The present paper summarizes the models for scrubbing of gaseous Iodine components in these codes, discusses the experimental validation, and gives an assessment of the state of knowledge reached and the open questions which persist. The retention of gaseous Iodine components is modelled by the various codes in a very heterogeneous manner. Differences show up in the chemical species considered, the treatment of mass transfer boundary layers on the gaseous and liquid sides, the gas-liquid interface geometry, calculation of equilibrium concentrations and numerical procedures. Especially important is the determination of the pool water pH value. This value is affected by basic aerosols deposited in the water, e.g. Cesium and Rubidium compounds. A consistent model requires a mass balance of these compounds in the pool, thus effectively coupling the pool scrubbing phenomena of aerosols and gaseous Iodine species. Since the water pool conditions are also affected by drainage flow of condensate water from different regions in the containment, and desorption of dissolved gases on the pool surface is determined by the gas concentrations above the pool, some basic limitations of specialized pool scrubbing codes are given. The paper draws conclusions about the necessity of coupling between containment thermal-hydraulics and pool scrubbing models, and proposes ways of further simulation model development in order to improve source term predictions. (author) 2 tabs., refs

  2. Self-formed waterfall plunge pools in homogeneous rock

    Science.gov (United States)

    Scheingross, Joel S.; Lo, Daniel Y.; Lamb, Michael P.

    2017-01-01

    Waterfalls are ubiquitous, and their upstream propagation can set the pace of landscape evolution, yet no experimental studies have examined waterfall plunge pool erosion in homogeneous rock. We performed laboratory experiments, using synthetic foam as a bedrock simulant, to produce self-formed waterfall plunge pools via particle impact abrasion. Plunge pool vertical incision exceeded lateral erosion by approximately tenfold until pools deepened to the point that the supplied sediment could not be evacuated and deposition armored the pool bedrock floor. Lateral erosion of plunge pool sidewalls continued after sediment deposition, but primarily at the downstream pool wall, which might lead to undermining of the plunge pool lip, sediment evacuation, and continued vertical pool floor incision in natural streams. Undercutting of the upstream pool wall was absent, and our results suggest that vertical drilling of successive plunge pools is a more efficient waterfall retreat mechanism than the classic model of headwall undercutting and collapse in homogeneous rock.

  3. Decontamination of outdoor school swimming pools in Fukushima after the nuclear accident in March 2011.

    Science.gov (United States)

    Saegusa, J; Kurikami, H; Yasuda, R; Kurihara, K; Arai, S; Kuroki, R; Matsuhashi, S; Ozawa, T; Goto, H; Takano, T; Mitamura, H; Nagano, T; Naganawa, H; Yoshida, Z; Funaki, H; Tokizawa, T; Nakayama, S

    2013-03-01

    Because of radioactive fallout resulting from the Fukushima Daiichi Nuclear Power Plant (NPP) accident, water discharge from many outdoor swimming pools in Fukushima was suspended out of concern that radiocesium in the pool water would flow into farmlands. The Japan Atomic Energy Agency has reviewed the existing flocculation method for decontaminating pool water and established a practical decontamination method by demonstrating the process at eight pools in Fukushima. In this method, zeolite powder and a flocculant are used for capturing radiocesium present in pool water. The supernatant is discharged if the radiocesium concentration is less than the targeted level. The radioactive residue is collected and stored in a temporary storage space. Radioactivity concentration in water is measured with a NaI(Tl) or Ge detector installed near the pool. The demonstration results showed that the pool water in which the radiocesium concentration was more than a few hundred Bq L was readily purified by the method, and the radiocesium concentration was reduced to less than 100 Bq L. The ambient dose rates around the temporary storage space were slightly elevated; however, the total increase was up to 30% of the background dose rates when the residue was shielded with sandbags.

  4. Microbial contributions to coupled arsenic and sulfur cycling in the acid-sulfide hot spring Champagne Pool, New Zealand.

    Science.gov (United States)

    Hug, Katrin; Maher, William A; Stott, Matthew B; Krikowa, Frank; Foster, Simon; Moreau, John W

    2014-01-01

    Acid-sulfide hot springs are analogs of early Earth geothermal systems where microbial metal(loid) resistance likely first evolved. Arsenic is a metalloid enriched in the acid-sulfide hot spring Champagne Pool (Waiotapu, New Zealand). Arsenic speciation in Champagne Pool follows reaction paths not yet fully understood with respect to biotic contributions and coupling to biogeochemical sulfur cycling. Here we present quantitative arsenic speciation from Champagne Pool, finding arsenite dominant in the pool, rim and outflow channel (55-75% total arsenic), and dithio- and trithioarsenates ubiquitously present as 18-25% total arsenic. In the outflow channel, dimethylmonothioarsenate comprised ≤9% total arsenic, while on the outflow terrace thioarsenates were present at 55% total arsenic. We also quantified sulfide, thiosulfate, sulfate and elemental sulfur, finding sulfide and sulfate as major species in the pool and outflow terrace, respectively. Elemental sulfur concentration reached a maximum at the terrace. Phylogenetic analysis of 16S rRNA genes from metagenomic sequencing revealed the dominance of Sulfurihydrogenibium at all sites and an increased archaeal population at the rim and outflow channel. Several phylotypes were found closely related to known sulfur- and sulfide-oxidizers, as well as sulfur- and sulfate-reducers. Bioinformatic analysis revealed genes underpinning sulfur redox transformations, consistent with sulfur speciation data, and illustrating a microbial role in sulfur-dependent transformation of arsenite to thioarsenate. Metagenomic analysis also revealed genes encoding for arsenate reductase at all sites, reflecting the ubiquity of thioarsenate and a need for microbial arsenate resistance despite anoxic conditions. Absence of the arsenite oxidase gene, aio, at all sites suggests prioritization of arsenite detoxification over coupling to energy conservation. Finally, detection of methyl arsenic in the outflow channel, in conjunction with

  5. Comparison of fecal pooling strategies for detection of Mycobacterium avium ssp. paratuberculosis in cattle.

    Science.gov (United States)

    McKenna, S L B; Ritter, C; Dohoo, I; Keefe, G P; Barkema, H W

    2018-05-23

    In herds with typical moderate to low within-herd prevalence, testing for Mycobacterium avium ssp. paratuberculosis (MAP), the infectious agent of Johne's disease, will be more cost-effective if individual fecal samples are cultured in composite pools. However, sensitivity to classify a pool containing 1 or more positive individual samples as positive may depend on pool size and number of individual positive samples within a pool. Fecal samples collected from 994 dairy cows sampled at slaughter were cultured to detect MAP. Culturing was done both individually and as composite pooled samples using the TREK ESP Culture System II broth medium (Thermo Fisher Scientific, Trek Diagnostic Systems Inc., Cleveland, OH). Composite samples consisted of pools containing feces from 3, 5, 8, 10, or 15 cows. The number of individual fecal culture-positive cows within each pool ranged from 0 to 4. Culture of individual fecal samples detected MAP in 36 (3.6%) of the 994 cows. Individual samples that were detected within the first 50 d by TREK ESP Culture System II were more likely to lead to a positive pool result. In total, 840 pooled fecal samples were examined for presence of MAP, and of those, 272 pools actually contained feces from fecal culture-positive cows. The crude sensitivity (proportion of pools that contained at least 1 fecal-positive cow that tested positive) for pools of 3, 5, 8, 10, and 15 was 47, 67, 44, 59, and 39%, respectively. Across pools, an increase of the number of fecal culture-positive samples from 1 to 2 enhanced overall crude sensitivity from 44 to 71%. However, sensitivity did not further increase for pools with 3 or 4 fecal culture-positive samples (63 and 60%, respectively). Additionally, a simulation analysis assessing probability of pooled fecal samples being positive in herds of 50 and 100 cows was conducted. The simulation assumed that 1, 2, or 5 cows per herd were MAP fecal culture-positive and that pools of 5 and 10 were used. This low

  6. Patent pools: Intellectual property rights and competition.

    NARCIS (Netherlands)

    Rodriguez, V.F.

    2010-01-01

    Patent pools do not correct all problems associated with patent thickets. In this respect, patent pools might not stop the outsider problem from striking pools. Moreover, patent pools can be expensive to negotiate, can exclude patent holders with smaller numbers of patents or enable a group of major

  7. Analysis of sodium pool fire in SFEF for assessing the limiting pool fire

    International Nuclear Information System (INIS)

    Mangarjuna Rao, P.; Ramesh, S.S.; Nashine, B.K.; Kasinathan, N.; Chellapandi, P.

    2011-01-01

    Accidental sodium leaks and resultant sodium fires in Liquid Metal Fast Breeder Reactor (LMFBR) systems can create a threat to the safe operation of the plant. To avoid this defence-in depth approach is implemented from the design stage of reactor itself. Rapid detection of sodium leak and fast dumping of the sodium into the storage tank of a defective circuit, leak collection trays, adequate lining of load bearing structural concrete and extinguishment of the sodium fire are the important defensive measures in the design, construction and operation of a LMFBR for protection against sodium leaks and their resultant fires. Evaluation of sodium leak events and their consequences by conducting large scale engineering experiments is very essential for effective implementation of the above protection measures for sodium fire safety. For this purpose a Sodium Fire Experimental Facility (SFEF) is constructed at SED, IGCAR. SFEF is having an experimental hall of size 9 m x 6 m x 10 m with 540 m 3 volume and its design pressure is 50 kPa. It is a concrete structure and provided with SS 304 liner, which is fixed to the inside surfaces of walls, ceiling and floor. A leak tight door of size (1.8 m x 2.0 m) is provided to the experimental hall and the facility is provided with a sodium equipment hall and a control room. Experimental evaluation of sodium pool fire consequences is an important activity in the LMFBR sodium fire safety related studies. An experimental program has been planned for different types of sodium fire studies in SFEF. A prior to that numerical analysis have been carried out for enclosed sodium pool fires using SOFIRE-II sodium pool fire code for SFEF experimental hall configuration to evaluate the limiting pool fire. This paper brings out results of the analysis carried out for this purpose. Limiting pool fire of SFEF depends on the exposed surface area of the pool, amount of sodium in the pool, oxygen concentration and initial sodium temperature. Limiting

  8. Pooled inventory management: a unique cost-sharing program

    International Nuclear Information System (INIS)

    Bromenschenkel, K.E.

    1984-01-01

    A totally fresh approach to stocking an inventory of costly, long-lead-time nuclear plant equipment became a reality in January, 1981, after three years of effort to form the program. The program, known as Pooled Inventory Management (PIM), is now procuring the first equipment to be stocked in its inventory. This report describes the formation of PIM, how the program works, PIM accomplishments, equipment included in PIM stockpiles, and economics, implementation, and future plans of the program

  9. 13 CFR 120.1705 - Pool formation requirements.

    Science.gov (United States)

    2010-01-01

    ... requirements. SBA may adjust the Pool characteristics periodically based on program experience and market... a Pool involving a Pool Loan it does not own, it must purchase the Loan Interest it proposes to pool... purchase the Loan Interest and take it into inventory or settle the purchase of the Loan Interest through...

  10. 1968 Listing of Swimming Pool Equipment.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI. Testing Lab.

    An up-to-date listing of swimming pool equipment including--(1) companies authorized to display the National Sanitation Foundation seal of approval, (2) equipment listed as meeting NSF swimming pool equipment standards relating to diatomite type filters, (3) equipment listed as meeting NSF swimming pool equipment standard relating to sand type…

  11. Microbial contributions to coupled arsenic and sulfur cycling in the acid-sulfide hot spring Champagne Pool, New Zealand

    Directory of Open Access Journals (Sweden)

    Katrin eHug

    2014-11-01

    Full Text Available Acid-sulfide hot springs are analogs of early Earth geothermal systems where microbial metal(loid resistance likely first evolved. Arsenic is a metalloid enriched in the acid-sulfide hot spring Champagne Pool (Waiotapu, New Zealand. Arsenic speciation in Champagne Pool follows reaction paths not yet fully understood with respect to biotic contributions and coupling to biogeochemical sulfur cycling. Here we present quantitative arsenic speciation from Champagne Pool, finding arsenite dominant in the pool, rim and outflow channel (55-75% total arsenic, and dithio- and trithioarsenates ubiquitously present as 18-25% total arsenic. In the outflow channel, dimethylmonothioarsenate comprised ≤9% total arsenic, while on the outflow terrace thioarsenates were present at 55% total arsenic. We also quantified sulfide, thiosulfate, sulfate and elemental sulfur, finding sulfide and sulfate as major species in the pool and outflow terrace, respectively. Elemental sulfur reached a maximum at the terrace. Phylogenetic analysis of 16S rRNA genes from metagenomic sequencing revealed the dominance of Sulfurihydrogenibium at all sites and an increased archaeal population at the rim and outflow channel. Several phylotypes were found closely related to known sulfur- and sulfide-oxidizers, as well as sulfur- and sulfate-reducers. Bioinformatic analysis revealed genes underpinning sulfur redox transformations, consistent with sulfur speciation data, and illustrating a microbial role in sulfur-dependent transformation of arsenite to thioarsenate. Metagenomic analysis also revealed genes encoding for arsenate reductase at all sites, reflecting the ubiquity of thioarsenate and a need for microbial arsenate resistance despite anoxic conditions. Absence of the arsenite oxidase gene, aio, at all sites suggests prioritization of arsenite detoxification over coupling to energy conservation. Finally, detection of methyl arsenic in the outflow channel, in conjunction with

  12. A strategy for optimizing item-pool management

    NARCIS (Netherlands)

    Ariel, A.; van der Linden, Willem J.; Veldkamp, Bernard P.

    2006-01-01

    Item-pool management requires a balancing act between the input of new items into the pool and the output of tests assembled from it. A strategy for optimizing item-pool management is presented that is based on the idea of a periodic update of an optimal blueprint for the item pool to tune item

  13. Swimming Pools and Molluscum Contagiosum

    Science.gov (United States)

    ... Travelers’ Health: Smallpox & Other Orthopoxvirus-Associated Infections Poxvirus Swimming Pools Recommend on Facebook Tweet Share Compartir The ... often ask if molluscum virus can spread in swimming pools. There is also concern that it can ...

  14. Pooling and correlated neural activity

    Directory of Open Access Journals (Sweden)

    Robert Rosenbaum

    2010-04-01

    Full Text Available Correlations between spike trains can strongly modulate neuronal activity and affect the ability of neurons to encode information. Neurons integrate inputs from thousands of afferents. Similarly, a number of experimental techniques are designed to record pooled cell activity. We review and generalize a number of previous results that show how correlations between cells in a population can be amplified and distorted in signals that reflect their collective activity. The structure of the underlying neuronal response can significantly impact correlations between such pooled signals. Therefore care needs to be taken when interpreting pooled recordings, or modeling networks of cells that receive inputs from large presynaptic populations. We also show that the frequently observed runaway synchrony in feedforward chains is primarily due to the pooling of correlated inputs.

  15. Method of measuring a liquid pool volume

    Science.gov (United States)

    Garcia, G.V.; Carlson, N.M.; Donaldson, A.D.

    1991-03-19

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools is disclosed, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figures.

  16. Design and Construction of Pool Door for Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kwangsub; Lee, Sangjin; Choi, Jinbok; Oh, Jinho; Lee, Jongmin [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The pool door is a structure to isolate the reactor pool from the service pool for maintenance. The pool door is installed before the reactor pool is drained. The pool door consists of structural component and sealing component. The main structures of the pool door are stainless steel plates and side frames. The plates and frames are assembled by welded joints. Lug is welded at the top of the plate. The pool door is submerged in the pool water when it is used. Materials of the pool door should be resistive to corrosion and radiation. Stainless steel is used in structural components and air nozzle assemblies. Features of design and construction of the pool door for the research reactor are introduced. The pool door is designed to isolate the reactor pool for maintenance. Structural analysis is performed to evaluate the structural integrity during earthquake. Tests and inspections are also carried out during construction to identify the safety and function of the pool door.

  17. Design and Construction of Pool Door for Research Reactor

    International Nuclear Information System (INIS)

    Jung, Kwangsub; Lee, Sangjin; Choi, Jinbok; Oh, Jinho; Lee, Jongmin

    2016-01-01

    The pool door is a structure to isolate the reactor pool from the service pool for maintenance. The pool door is installed before the reactor pool is drained. The pool door consists of structural component and sealing component. The main structures of the pool door are stainless steel plates and side frames. The plates and frames are assembled by welded joints. Lug is welded at the top of the plate. The pool door is submerged in the pool water when it is used. Materials of the pool door should be resistive to corrosion and radiation. Stainless steel is used in structural components and air nozzle assemblies. Features of design and construction of the pool door for the research reactor are introduced. The pool door is designed to isolate the reactor pool for maintenance. Structural analysis is performed to evaluate the structural integrity during earthquake. Tests and inspections are also carried out during construction to identify the safety and function of the pool door

  18. Structural integrity assessment of HANARO pool cover

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo

    2001-11-01

    This report is for the seismic analysis and the structural integrity evaluation of HANARO Pool Cover in accordances with the requirement of the Technical Specification for Seismic Analysis of HANARO Pool Cover. For performing the seismic analysis and evaluating the structural integrity for HANARO Pool Cover, the finite element analysis model using ANSYS 5.7 was developed and the dynamic characteristics were analyzed. The seismic response spectrum analyses of HANARO Pool Cover under the design floor response spectrum loads of OBE and SSE were performed. The analysis results show that the stress values in HANARO Pool Cover for the seismic loads are within the ASME Code limits. It is also confirmed that the fatigue usage factor is less than 1.0. Therefore any damage on structural integrity is not expected when an HANARO Pool Cover is installed in the upper part of the reactor pool

  19. Spatial Distribution of Zooplankton Diversity across Temporary Pools in a Semiarid Intermittent River

    Directory of Open Access Journals (Sweden)

    Thaís X. Melo

    2013-01-01

    Full Text Available This study describes the richness and density of zooplankton across temporary pools in an intermittent river of semiarid Brazil and evaluates the partitioning of diversity across different spatial scales during the wet and dry periods. Given the highly patchy nature of these pools it is hypothesized that the diversity is not homogeneously distributed across different spatial scales but concentrated at lower levels. The plankton fauna was composed of 37 species. Of these 28 were Rotifera, 5 were Cladocera, and 4 were Copepoda (nauplii of Copepoda were also recorded. We showed that the zooplankton presents a spatially segregated pattern of species composition across river reaches and that at low spatial scales (among pools or different habitats within pools the diversity of species is likely to be affected by temporal changes in physical and chemical characteristics. As a consequence of the drying of pool habitats, the spatial heterogeneity within the study river reaches has the potential to increase β diversity during the dry season by creating patchier assemblages. This spatial segregation in community composition and the patterns of partition of the diversity across the spatial scales leads to a higher total diversity in intermittent streams, compared to less variable environments.

  20. Collaborative Car Pooling System

    OpenAIRE

    João Ferreira; Paulo Trigo; Porfírio Filipe

    2009-01-01

    This paper describes the architecture for a collaborative Car Pooling System based on a credits mechanism to motivate the cooperation among users. Users can spend the accumulated credits on parking facilities. For this, we propose a business model to support the collaboration between a car pooling system and parking facilities. The Portuguese Lisbon-s Metropolitan area is used as application scenario.

  1. Eco-engineered rock pools: a concrete solution to biodiversity loss and urban sprawl in the marine environment

    Science.gov (United States)

    Firth, Louise B.; Browne, Keith A.; Knights, Antony M.; Hawkins, Stephen J.; Nash, Róisín

    2016-09-01

    In coastal habitats artificial structures typically support lower biodiversity and can support greater numbers of non-native and opportunistic species than natural rocky reefs. Eco-engineering experiments are typically trialed to succeed; but arguably as much is learnt from failure than from success. Our goal was to trial a generic, cost effective, eco-engineering technique that could be incorporated into rock armouring anywhere in the world. Artificial rock pools were created from manipulated concrete between boulders on the exposed and sheltered sides of a causeway. Experimental treatments were installed in locations where they were expected to fail and compared to controls installed in locations in which they were expected to succeed. Control pools were created lower on the structure where they were immersed on every tidal cycle; experimental pools were created above mean high water spring tide which were only immersed on spring tides. We hypothesised that lower and exposed pools would support significantly higher taxon and functional diversity than upper and sheltered pools. The concrete pools survived the severe winter storms of 2013/14. After 12 months, non-destructive sampling revealed significantly higher mean taxon and functional richness in lower pools than upper pools on the exposed side only. After 24 months the sheltered pools had become inundated with sediments, thus failing to function as rock pools as intended. Destructive sampling on the exposed side revealed significantly higher mean functional richness in lower than upper pools. However, a surprisingly high number of taxa colonised the upper pools leading to no significant difference in mean taxon richness among shore heights. A high number of rare taxa in the lower pools led to total taxon richness being almost twice that of upper pools. These findings highlight that even when expected to fail concrete pools supported diverse assemblages, thus representing an affordable, replicable means of

  2. Fully Automated Lipid Pool Detection Using Near Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Elżbieta Pociask

    2016-01-01

    Full Text Available Background. Detecting and identifying vulnerable plaque, which is prone to rupture, is still a challenge for cardiologist. Such lipid core-containing plaque is still not identifiable by everyday angiography, thus triggering the need to develop a new tool where NIRS-IVUS can visualize plaque characterization in terms of its chemical and morphologic characteristic. The new tool can lead to the development of new methods of interpreting the newly obtained data. In this study, the algorithm to fully automated lipid pool detection on NIRS images is proposed. Method. Designed algorithm is divided into four stages: preprocessing (image enhancement, segmentation of artifacts, detection of lipid areas, and calculation of Lipid Core Burden Index. Results. A total of 31 NIRS chemograms were analyzed by two methods. The metrics, total LCBI, maximal LCBI in 4 mm blocks, and maximal LCBI in 2 mm blocks, were calculated to compare presented algorithm with commercial available system. Both intraclass correlation (ICC and Bland-Altman plots showed good agreement and correlation between used methods. Conclusions. Proposed algorithm is fully automated lipid pool detection on near infrared spectroscopy images. It is a tool developed for offline data analysis, which could be easily augmented for newer functions and projects.

  3. PPOOLEX experiments on stratification and mixing in the wet well pool

    International Nuclear Information System (INIS)

    Laine, J.; Puustinen, M.; Raesaenen, A.; Tanskanen, V.

    2011-03-01

    This report summarizes the results of the thermal stratification and mixing experiments carried out in 2010 with the scaled down, two compartment PPOOLEX test facility designed and constructed at LUT. Steam was blown into the thermally insulated dry well compartment and from there through the DN200 vertical blowdown pipe to the condensation pool filled with sub-cooled water. The main purpose of the experiment series was to generate verification data for evaluating the capability of GOTHIC and APROS codes to predict stratification and mixing phenomena. Another objective was to test the sound velocity measurement system. Altogether five experiments were carried out. The experiments consisted of a small steam flow rate stratification period and of a mixing period with continuously or stepwise increasing flow rate. The dry well structures were heated up to the level of approximately 90 deg. C before the actual experiments. The initial water bulk temperature was 20 deg. C. When the steam flow rate was low enough (typically ∼100-150 g/s) temperatures below the blowdown pipe outlet remained constant while increasing heat-up occurred towards the pool surface layers indicating strong thermal stratification of the wet well pool water. During the stratification period the highest measured temperature difference between pool bottom and surface was approximately 40 deg. C. During the mixing period total mixing of the pool volume was not achieved in any of the experiments. The bottom layers heated up significantly but never reached the same temperature as the topmost layers. The lowest measured temperature difference between the pool bottom and surface was 7-8 deg. C. According to the test results, it seems that a small void fraction doesn't have an effect on the speed of sound in water and that the acquired sound velocity measurement system cannot be used for the estimation of void fraction in the wet well water pool. However, more tests on this issue have to be executed

  4. PPOOLEX experiments on stratification and mixing in the wet well pool

    Energy Technology Data Exchange (ETDEWEB)

    Laine, J.; Puustinen, M.; Raesaenen, A.; Tanskanen, V. (Lappeenranta Univ. of Technology, Nuclear Safety Research Unit (Finland))

    2011-03-15

    This report summarizes the results of the thermal stratification and mixing experiments carried out in 2010 with the scaled down, two compartment PPOOLEX test facility designed and constructed at LUT. Steam was blown into the thermally insulated dry well compartment and from there through the DN200 vertical blowdown pipe to the condensation pool filled with sub-cooled water. The main purpose of the experiment series was to generate verification data for evaluating the capability of GOTHIC and APROS codes to predict stratification and mixing phenomena. Another objective was to test the sound velocity measurement system. Altogether five experiments were carried out. The experiments consisted of a small steam flow rate stratification period and of a mixing period with continuously or stepwise increasing flow rate. The dry well structures were heated up to the level of approximately 90 deg. C before the actual experiments. The initial water bulk temperature was 20 deg. C. When the steam flow rate was low enough (typically approx100-150 g/s) temperatures below the blowdown pipe outlet remained constant while increasing heat-up occurred towards the pool surface layers indicating strong thermal stratification of the wet well pool water. During the stratification period the highest measured temperature difference between pool bottom and surface was approximately 40 deg. C. During the mixing period total mixing of the pool volume was not achieved in any of the experiments. The bottom layers heated up significantly but never reached the same temperature as the topmost layers. The lowest measured temperature difference between the pool bottom and surface was 7-8 deg. C. According to the test results, it seems that a small void fraction doesn't have an effect on the speed of sound in water and that the acquired sound velocity measurement system cannot be used for the estimation of void fraction in the wet well water pool. However, more tests on this issue have to be

  5. Linking tree demography to climate change feedbacks: fire, larch forests, and carbon pools of the Siberian Arctic

    Science.gov (United States)

    Alexander, H. D.; Loranty, M. M.; Natali, S.; Pena, H., III; Ludwig, S.; Spektor, V.; Davydov, S. P.; Zimov, N.; Mack, M. C.

    2017-12-01

    Fire severity is increasing in larch forests of the Siberian Arctic as climate warms, and initial fire impacts on tree demographic processes could be an especially important determinant of long-term forest structure and carbon (C) dynamics. We hypothesized that (1) larch forest regrowth post-fire is largely determined by residual soil organic layer (SOL) depth because of the SOL's role as a seedbed and thermal regulator, and (2) changes in post-fire larch recruitment impact C accumulation through stand density impacts on understory microclimate and permafrost thaw. We tested these hypotheses by (1) experimentally creating a soil burn severity gradient in a Cajander larch (Larix cajanderi Mayr.) forest near Cherskiy, Russia and (2) quantifying C pools across a stand density gradient within a 75-year old fire scar. From 2012-2015, we added larch seeds to plots burned at different severities and monitored recruitment along with permafrost and active layer (i.e., subject to annual freeze-thaw) conditions (SOL depth, temperature, moisture, and thaw depth). Across the density gradient, we inventoried larch trees and harvested ground-layer vegetation to estimate aboveground contribution to C pools. We quantified woody debris C pools and sampled belowground C pools (soil, fine roots, and coarse roots) in the organic + upper (0-10 cm) mineral soil. Larch recruits were rare in unburned and low severity plots, but a total of 6 new germinants m-2 were tallied in moderate and high severity plots during the study. Seedling survival for > 1 year was only 40 and 25% on moderate and high severity treatments, respectively, but yielded net larch recruitment of 2 seedlings m-2, compared to 0.3 seedlings m-2 on low severity plots. Density of both total and established recruits increased with decreasing residual SOL depth, which correlated with increased soil temperature, moisture, and thaw depth. At 75-year post-fire, total C pools increased with increased larch density, largely due to

  6. Life cycle environmental implications of residential swimming pools.

    Science.gov (United States)

    Forrest, Nigel; Williams, Eric

    2010-07-15

    Ownership of private swimming pools in the U.S. grew 2 to 4% per annum from 1997 to 2007. The environmental implications of pool ownership are analyzed by hybrid life cycle assessment (LCA) for nine U.S. cities. An operational model is constructed estimating consumption of chemicals, water, and energy for a typical residential pool. The model incorporates geographical climatic variations and upstream water and energy use from electricity and water supply networks. Results vary considerably by city: a factor of 5-6 for both water and energy use. Water use is driven by aridness and length of the swimming season, while energy use is mainly driven by length of the swimming season. Water and energy impacts of pools are significant, particularly in arid climates. In Phoenix for example pools account for 22% and 13% of a household's electricity and water use, respectively. Measures to reduce water and energy use in pools such as optimizing the pump schedule and covering the pool in winter can realize greater savings than many common household efficiency improvements. Private versus community pools are also compared. Community pools in Phoenix use 60% less swimming pool water and energy per household than subdivisions without community pools.

  7. Slower lower limb blood pooling in young women with orthostatic intolerance.

    Science.gov (United States)

    Lindenberger, Marcus; Länne, Toste

    2015-01-01

    What is the central question of this study? Orthostatic stress is mostly caused by venous blood pooling in the lower limbs. Venous distension elicits sympathetic responses, and increased distension speed enhances the cardiovascular response. We examine whether lower limb blood pooling rate during lower body negative pressure is linked to orthostatic intolerance. What is the main finding and its importance? A similar amount of blood was pooled in the lower limb, but at a slower rate in women who developed signs of orthostatic intolerance. The difference in blood pooling rate increased with orthostatic stress and was most prominent at a presyncope-inducing level of lower body negative pressure. The findings have implications for the pathophysiology as well as treatment of orthostatic intolerance. Vasovagal syncope is common in young women, but its aetiology remains elusive. Orthostatic stress-induced lower limb blood pooling is linked with central hypovolaemia and baroreceptor unloading. Venous distension in the arm elicits a sympathetic response, which is enhanced with more rapid distension. Our aim was to study both the amount and the speed of lower limb pooling during orthostatic stress and its effects on compensatory mechanisms to maintain cardiovascular homeostasis in women with orthostatic intolerance. Twenty-seven healthy women, aged 20-27 years, were subjected to a lower body negative pressure (LBNP) of 11-44 mmHg. Five women developed symptoms of vasovagal syncope (orthostatic intolerant) and were compared with the remaining women, who tolerated LBNP well (orthostatic tolerant). Lower limb blood pooling, blood flow and compensatory mobilization of venous capacitance blood were measured. Lower body negative pressure induced equal lower limb blood pooling in both groups, but at a slower rate in orthostatic intolerant women (e.g. time to 50% of total blood pooling, orthostatic intolerant 44 ± 7 s and orthostatic tolerant 26 ± 2 s; P intolerant women (P = 0

  8. Influence of a swimming-pool on fertility in buffalo species

    Directory of Open Access Journals (Sweden)

    Luigi Zicarelli

    2010-01-01

    Full Text Available The aim of this study was to verify the effect of a swimming-pool on reproductive efficiency in buffalo species. The trial was performed in a commercial buffalo farm, where lactating buffaloes were divided into two groups (G1 and G2, and only in G1 a swimming-pool was available. Data of a 4-years period (1999–2002 were analysed. Statistical analysis of calving-conception interval (CCI of a first 3-years period (1999–2001, after logarithmic conversion, was performed by “t” Student’s Test while the percentage data were analyzed by Chi-square test. Animals in G1 showed higher conception rate within 120 days post calving (53.7% vs. 39.9%; P<0.001 in both deliveries of January-March and April-August. During the first 2 years (1999–2000 the CCI of buffaloes that delivered in January- March period was longer (P<0.001 than that of April-August. Furthermore, on the total of the 3 years the CCI was longer (P<0.01 in buffaloes of G2 compared to G1. Because of the presence of a swimming- pool also for G2 from 2002 May, the conception rate of not pregnant subjects characterized by more than 40 days open in 2001 and 2002 was also calculated and the favourable effect was confirmed. These results highlight the beneficial effect of a swimming-pool on fertility in buffalo species.

  9. Structure for nuclear fuel storage pools

    International Nuclear Information System (INIS)

    Ebata, Sakae; Nichiei, Shinji.

    1979-01-01

    Purpose: To enable leak detection in nuclear fuel storage pools, as well as prevent external leakages while keeping the strength of the constructional structures. Constitution: Protection plates are provided around pool linear plates and a leak reception is provided to the bottom. Leakages are detected by leak detecting pipeways and the external leakages are prevented by collecting them in a detection area provided in the intermediate layer. Since ferro-reinforcements at the bottom wall of the pool are disconnected by the protection plate making it impossible to form the constructional body, body hunches are provided to the bottom wall of the pool for processing the ferro-reinforcements. (Yoshino, Y.)

  10. Distributed Technologies in a Data Pool

    Science.gov (United States)

    Keiser, K.; Conover, H.; Graves, S.; He, Y.; Regner, K.; Smith, M.

    2004-12-01

    A Data Pool is an on-line repository providing interactive and programmatic access to data products through a variety of services. The University of Alabama in Huntsville has developed and deployed such a Data Pool in conjunction with the DISCOVER project, a collaboration with NASA and Remote Sensing Systems. DISCOVER provides long-term ocean and climate data from a variety of passive microwave satellite instruments, including such products as sea-surface temperature and wind, air temperature, atmospheric water vapor, cloud water and rain rate. The Data Pool provides multiple methods to access and visualize these products, including conventional HTTP and FTP access, as well as data services that provide for enhanced usability and interoperability, such as GridFTP, OPeNDAP, OpenGIS-compliant web mapping and coverage services, and custom subsetting and packaging services. This paper will focus on the distributed service technologies used in the Data Pool, which spans heterogeneous machines at multiple locations. For example, in order to provide seamless access to data at multiple sites, the Data Pool provides catalog services for all data products at the various data server locations. Under development is an automated metadata generation tool that crawls the online data repositories regularly to dynamically update the Data Pool catalog with information about newly generated data files. For efficient handling of data orders across distributed repositories, the Data Pool also implements distributed data processing services on the file servers where the data resides. Ontologies are planned to support automated service chaining for custom user requests. The UAH Data Pool is based on a configurable technology framework that integrates distributed data services with a web interface and a set of centralized database services for catalogs and order tracking. While this instantiation of the Data Pool was implemented to meet the needs of the DISCOVER project, the framework was

  11. Conjugated heat transfer of natural convection in pool with internal heat sources and convection in the tube

    International Nuclear Information System (INIS)

    Li Longjian; Liu Hongtao; Cui Wenzhi

    2007-01-01

    The conjugated heat transfer of natural convection in pool with internal heat source and the forced convection in the tube was analyzed, and the corresponding three-dimensional physical and mathematical model was proposed. A control volume based finite element method was employed to solve numerically the problem. The computations were performed for different internal heat source intensity of the pool and the different flow velocity in the tube. The computed heat transfer coefficients on the inner and outer wall showed well consistency of those calculated with the empirical correlations. Compared with the measured total heat transfer coefficients between the fluids in and out of the tube, the computed ones showed also the well consistency, which implied that the numerical model proposed in this paper was reliable. The research results revealed that the total heat transfer coefficients between the fluids were strongly affected by the internal heat source intensity of the pool liquid and the flow velocity in the tube. (authors)

  12. Spent fuel pool cleanup and stabilization

    International Nuclear Information System (INIS)

    Miller, R.L.

    1987-06-01

    Each of the plutonium production reactors at Hanford had a large water-filled spent fuel pool to provide interim storage of irradiated fuel while awaiting shipment to the separation facilities. After cessation of reactor operations the fuel was removed from the pools and the water levels were drawn down to a 5- to 10-foot depth. The pools were maintained with the water to provide shielding and radiological control. What appeared to be a straightforward project to process the water, remove the sediments from the basin, and stabilize the contamination on the floors and walls became a very complex and time consuming operation. The sediment characteristics varied from pool to pool, the ion exchange system required modification, areas of hard-pack sediments were discovered on the floors, special arrangements to handle and package high dose rate items for shipment were required, and contract problems ensued with the subcontractor. The original schedule to complete the project from preliminary engineering to final stabilization of the pools was 15 months. The actual time required was about 25 months. The original cost estimate to perform the work was $2,651,000. The actual cost of the project was $5,120,000, which included $150,000 for payment of claims to the subcontractor. This paper summarizes the experiences associated with the cleanup and radiological stabilization of the 100-B, -C, -D, and -DR spent fuel pools, and discusses a number of lessons learned items

  13. Evaporation-preventive device for nuclear reactor pool water

    International Nuclear Information System (INIS)

    Kurusu, Yoshihisa; Akabori, Shiro.

    1986-01-01

    Purpose: To prevent pool water from evaporating by a great amount in a reactor pool such as a spent fuel storing pool. Constitution: Air discharge and in-take ports are disposed just above the surface of the pool water and charge and discharge of airs are forcively carried out to form air curtains above the pool water. Water vapor evaporated from the surface of the pool water does not diffuse above the air curtains due to the air stream of the curtains, but is intaken into the intake port and then condensated into water by a steam condensator and re-supplied to the pool. Since diffusion of water vapor and radioactive materials are suppressed above the air curtains, the working circumstance in the pool chamber can be maintained desirably thereby keeping the radioactivity dose in the atmosphere. Further, incorporation of dusts from above into the pool can also be prevented by the air curtains to provide an effect for the prevention of radioactive contamination. Further, since covers are not used, visual observation can be insured. (Kawakami, Y.)

  14. Ripples in a superconducting tidal pool

    CERN Document Server

    Hudson, E

    2003-01-01

    The behaviour of electrons in a metal is often compared to that of water in a pool. An empty pool is like a material that has all of its electrons removed. As electrons are 'poured' into the metal, they first occupy the lowest energies available - the bottom of the pool - and eventually fill up to the Fermi energy, the top of the pool. At this point we no longer discuss electrons but quasiparticles. These are electrons that have modified properties due to their interactions within the material. Waves in a pool can be excited, and their properties will depend on the depth of the water. Similarly in a metal, quasiparticles behave like waves that have a material-dependent dispersion relation between their energy and their wavevector, which specifies their direction and wavelength. This simple analogy also hints at an indirect method of measuring the dispersion relation of a metal, and hence the myriad of properties that depend on it. (U.K.)

  15. Gene expression changes in blood RNA after swimming in a chlorinated pool.

    Science.gov (United States)

    Salas, Lucas A; Font-Ribera, Laia; Bustamante, Mariona; Sumoy, Lauro; Grimalt, Joan O; Bonnin, Sarah; Aguilar, Maria; Mattlin, Heidi; Hummel, Manuela; Ferrer, Anna; Kogevinas, Manolis; Villanueva, Cristina M

    2017-08-01

    Exposure to disinfection by-products (DBP) such as trihalomethanes (THM) in swimming pools has been linked to adverse health effects in humans, but their biological mechanisms are unclear. We evaluated short-term changes in blood gene expression of adult recreational swimmers after swimming in a chlorinated pool. Volunteers swam 40min in an indoor chlorinated pool. Blood samples were drawn and four THM (chloroform, bromodichloromethane, dibromochloromethane and bromoform) were measured in exhaled breath before and after swimming. Intensity of physical activity was measured as metabolic equivalents (METs). Gene expression in whole blood mRNA was evaluated using IlluminaHumanHT-12v3 Expression-BeadChip. Linear mixed models were used to evaluate the relationship between gene expression changes and THM exposure. Thirty-seven before-after pairs were analyzed. The median increase from baseline to after swimming were: 0.7 to 2.3 for MET, and 1.4 to 7.1μg/m 3 for exhaled total THM (sum of the four THM). Exhaled THM increased on average 0.94μg/m 3 per 1 MET. While 1643 probes were differentially expressed post-exposure. Of them, 189 were also associated with exhaled levels of individual/total THM or MET after False Discovery Rate. The observed associations with the exhaled THM were low to moderate (Log-fold change range: -0.17 to 0.15). In conclusion, we identified short-term gene expression changes associated with swimming in a pool that were minor in magnitude and their biological meaning was unspecific. The high collinearity between exhaled THM levels and intensity of physical activity precluded mutually adjusted models with both covariates. These exploratory results should be validated in future studies. Copyright © 2017. Published by Elsevier B.V.

  16. Swimming pools as heat sinks for air conditioners: Model design and experimental validation for natural thermal behavior of the pool

    Energy Technology Data Exchange (ETDEWEB)

    Woolley, Jonathan; Harrington, Curtis; Modera, Mark [University of California Davis, Western Cooling Efficiency Center, 1450 Drew Avenue, Suite 100, Davis, CA 95618 (United States)

    2011-01-15

    Swimming pools as thermal sinks for air conditioners could save approximately 40% on peak cooling power and 30% of overall cooling energy, compared to standard residential air conditioning. Heat dissipation from pools in semi-arid climates with large diurnal temperature shifts is such that pool heating and space cooling may occur concurrently; in which case heat rejected from cooling equipment could directly displace pool heating energy, while also improving space cooling efficiency. The performance of such a system relies on the natural temperature regulation of swimming pools governed by evaporative and convective heat exchange with the air, radiative heat exchange with the sky, and conductive heat exchange with the ground. This paper describes and validates a model that uses meteorological data to accurately predict the hourly temperature of a swimming pool to within 1.1 C maximum error over the period of observation. A thorough review of literature guided our choice of the most appropriate set of equations to describe the natural mass and energy exchange between a swimming pool and the environment. Monitoring of a pool in Davis, CA, was used to confirm the resulting simulations. Comparison of predicted and observed pool temperature for all hours over a 56 day experimental period shows an R-squared relatedness of 0.967. (author)

  17. Generalizing Pooling Functions in CNNs: Mixed, Gated, and Tree.

    Science.gov (United States)

    Lee, Chen-Yu; Gallagher, Patrick; Tu, Zhuowen

    2018-04-01

    In this paper, we seek to improve deep neural networks by generalizing the pooling operations that play a central role in the current architectures. We pursue a careful exploration of approaches to allow pooling to learn and to adapt to complex and variable patterns. The two primary directions lie in: (1) learning a pooling function via (two strategies of) combining of max and average pooling, and (2) learning a pooling function in the form of a tree-structured fusion of pooling filters that are themselves learned. In our experiments every generalized pooling operation we explore improves performance when used in place of average or max pooling. We experimentally demonstrate that the proposed pooling operations provide a boost in invariance properties relative to conventional pooling and set the state of the art on several widely adopted benchmark datasets. These benefits come with only a light increase in computational overhead during training (ranging from additional 5 to 15 percent in time complexity) and a very modest increase in the number of model parameters (e.g., additional 1, 9, and 27 parameters for mixed, gated, and 2-level tree pooling operators, respectively). To gain more insights about our proposed pooling methods, we also visualize the learned pooling masks and the embeddings of the internal feature responses for different pooling operations. Our proposed pooling operations are easy to implement and can be applied within various deep neural network architectures.

  18. Nitrogen-15 natural abundance of different soil N pools as a tool for assessing N transformation processes in alpine soils

    Science.gov (United States)

    Makarov, Mikhail; Malysheva, Tatiana; Tiunov, Alexei; Kadulin, Maxim; Maslov, Mikhail

    2017-04-01

    Nitrogen availability, net N mineralization, nitrification and 15N natural abundance of total soil N and small soil N pools (N-NH4+, N-NO3-, DON and microbial biomass N) were studied in a toposequence of alpine ecosystems in the Northern Caucasus. The toposequence was represented by (1) low productive alpine lichen heath (ALH) of the wind-exposed ridge and upper slope; (2) more productive Festuca varia grassland (FG) of the middle slope; (3) most productive Geranium gymnocaulon/Hedysarum caucasicum meadow (GHM) of the lower slope and (4) low productive snow bed community (SBC) of the slope bottom. Nitrogen transformation in the alpine soils produces distinct N pools with different 15N enrichment: DON/microbial biomass N > total N > N-NH4+ > N-NO3-. Grassland and meadow soils of the middle part of the toposequence are characterized by higher nitrogen transformation activities and higher δ15 values of total N and N-NH4+. Field incubation of alpine soils increased δ15N of N-NH4+ from -2.6 - +2.0‰ to +6.1 - +15.7‰. The N-NO3-produced in the incubation experiment had extremely low (negative) δ15N values (up to -14‰). We found a positive correlation between δ15N of different soil N pools (total N, N-NH4+ and N-NO3-) and net N mineralization and nitrification. Nitrification controls the formation of 15N enriched N-NH4+ pool while N mineralization probably had an important role in regulation of 15N enrichment of DON pool in alpine soils. Overall, our results support the hypothesis that 15N is more enriched in N-rich and more depleted in N-poor ecosystems. We conclude that δ15N values of different soil N pools could be a good indicator of microbial N transformation in alpine soils of the Northern Caucasus. Acknowledgement: This study was supported by Russian Science Foundation (16-14-10208).

  19. Pools and rapids as spawning and nursery areas for fish in a river stretch without floodplains

    Directory of Open Access Journals (Sweden)

    Sunshine de Ávila-Simas

    Full Text Available This study aimed to evaluate the importance of two environments situated in the main channel of the Peixe River (a tributary of the upper Uruguay River on fish reproduction and initial growth. Ichthyoplankton, macrozooplankton, and zoobenthos collections were taken on a monthly basis from October 2011 to March 2012, sampling a rapids and a pool environment. The instrument used for the capture of the ichthyoplankton in both environments was a light trap. In total, 795 eggs and 274 larvae were captured. The species that presented higher abundance and occurrence frequency out of the total captured in both environments were Leporinus obtusidens, Bryconamericus iheringii, and Bryconamericus stramineus. The evaluation of the feeding activity reveals a major repletion degree of the larvae in more advanced stages in the pool. The pool environment presented a higher abundance of larvae in more advanced development stages. We conclude that the channel of the Peixe River is important for the reproduction and initial growth of fish and that each river environment seems to fulfill a different role in the life cycle of the ichthyoplankton community.

  20. Decommissioning of the pool reactor Thetis in Ghent, Belgium

    Energy Technology Data Exchange (ETDEWEB)

    Cortenbosch, Geert; Mommaert, Chantal [Bel V, Brussels (Belgium); Tierens, Hubert; Monsieurs, Myriam; Meierlaen, Isabelle; Strijckmans, Karel [Ghent Univ. (Belgium)

    2016-11-15

    The Thetis research pool reactor (with a nominal power of 150 kW) of the Ghent University was operational from 1967 till December 2003. The first phase of the decommissioning of the reactor, the removal of the spent fuel from the site, took place in 2010. The cumulative dose received was only 404 man . μSv. During the second phase, the transition period between the removal of the spent fuel in 2010 and the start of the decommissioning phase in March 2013, 3-monthly internal inspections and inspections by Bel V, were performed. The third and final decommissioning phase started on March 18, 2013. The total dose received between March 2013 and August 2013 was 1561 man . μSv. The declassification from a Class I installation to a Class II installation was possible by the end of 2015. The activated concrete in the reactor pool will remain under regulatory control until the activation levels are lower than the limits for free release.

  1. Technical specification for fabrication of HANARO pool cover

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Woo, Sang Ik

    2001-06-01

    This technical specification details the requirements and the acceptance criteria for design, seismic analysis, function test, installation and quality assurance for HANARO pool cover which will be installed at the top of reactor pool. The pool cover is classified as non-nuclear safety, seismic category II and quality class T. The basic design of the pool cover for increasing HANARO applications has been carried out for supporting the driving devices which can load, unload and rotate the irradiation targets in the in-core and out-core vertical irradiation holes under on-power operation. The comments of HANARO user group related with irradiation tests have optimally considered in the process of design. The interference between fuel handling and control absorber units in the reactor pool and activities to load, unload and rotate the irradiation targets at the top of the reactor pool have been minimized. The pool cover can be moved for maintenance and can protect the reactor pool from unexpected drop of foreign materials. It provides the space to vertical access of driving devices for NTD, CT/IR and OR4/OR5 under on-power operation. And the pool cover assembly must maintain its structural integrity under seismic load. Based on the above design concept, the HANARO pool cover has been proposed as supporting structure of driving devices for NTD, fission moly and RI production under on-power operation.

  2. Mandatory pooling as a supplement to risk-adjusted capitation payments in a competitive health insurance market.

    Science.gov (United States)

    Van Barneveld, E M; Lamers, L M; van Vliet, R C; van de Ven, W P

    1998-07-01

    Risk-adjusted capitation payments (RACPs) to competing health insurers are an essential element of market-oriented health care reforms in many countries. RACPs based on demographic variables only are insufficient, because they leave ample room for cream skimming. However, the implementation of improved RACPs does not appear to be straightforward. A solution might be to supplement imperfect RACPs with a form of mandatory pooling that reduces the incentives for cream skimming. In a previous paper it was concluded that high-risk pooling (HRP), is a promising supplement to RACPs. The purpose of this paper is to compare HRP with two other main variants of mandatory pooling. These variants are called excess-of-loss (EOL) and proportional pooling (PP). Each variant includes ex post compensations to insurers for some members which depend to various degrees on actually incurred costs. Therefore, these pooling variants reduce the incentives for cream skimming which are inherent in imperfect RACPs, but they also reduce the incentives for efficiency and cost containment. As a rough measure of the latter incentives we use the percentage of total costs for which an insurer is at risk. This paper analyzes which of the three main pooling variants yields the greatest reduction of incentives for cream skimming given such a percentage. The results show that HRP is the most effective of the three pooling variants.

  3. Decontamination of outdoor school swimming pools in Fukushima

    International Nuclear Information System (INIS)

    Saegusa, Jun

    2013-01-01

    After the Fukushima Daiichi NPP accident following the Great East Japan Earthquake, many school swimming pools in Fukushima have suspended water discharge, due to concerns that pool water which contains radioactive fallout is discharged into a river or waterway for agricultural use. The Japan Atomic Energy Agency conducted researches and examinations on the existing absorbent method and the flocculation method as ways for decontaminating pool water. By reviewing and improving these methods through decontamination demonstrations at eight pools in Fukushima, a practical decontamination method for outdoor pools has been established. This report summarizes the methods and results of the decontamination demonstrations carried out at the schools. Also, the surface density of fallout estimated at one of the pools is also presented and discussed in connection with the overall collection ratio of radiocesium at the pool. (author)

  4. 48 CFR 873.114 - Best value pool.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Best value pool. 873.114... SUPPLEMENTARY REGULATIONS SIMPLIFIED ACQUISITION PROCEDURES FOR HEALTH-CARE RESOURCES 873.114 Best value pool... solicitation. These vendors constitute the best value pool. This determination is within the sole discretion of...

  5. Antioxidant pool in beer and kinetics of EPR spin-trapping.

    Science.gov (United States)

    Kocherginsky, Nikolai M; Kostetski, Yuri Yu; Smirnov, Alex I

    2005-08-24

    The kinetics of spin-trap adduct formation in beer oxidation exhibits an induction period if the reaction is carried out at elevated temperatures and in the presence of air. This lag period lasts until the endogenous antioxidants are almost completely depleted, and its duration is used as an indicator of the flavor stability and shelf life of beer. This paper demonstrates that the total kinetics of the process can be characterized by three parameters-the lag period, the rate of spin-trap adduct formation, and, finally, the steady-state spin-adduct concentration. A steady-state chain reaction mechanism is described, and quantitative estimates of the main kinetic parameters such as the initiation rate, antioxidant pool, effective content of organic molecules participating in the chain reactions, and the rate constant of the 1-hydroxyethyl radical EtOH(*) spin-adduct disappearance are given. An additional new dimensionless parameter is suggested to characterize the antioxidant pool-the product of the lag time and the rate of spin-trap radical formation immediately after the lag time, normalized by the steady-state concentration of the adducts. The results of spin-tapping EPR experiments are compared with the nitroxide reduction kinetics measured in the same beer samples. It is shown that although the kinetics of nitroxide reduction in beer can be used to evaluate the reducing power of beer, the latter parameter does not correlate with the antioxidant pool. The relationship of free radical processes, antioxidant pool, reducing power, and beer staling is discussed.

  6. Low-Dose (10-Gy) Total Skin Electron Beam Therapy for Cutaneous T-Cell Lymphoma: An Open Clinical Study and Pooled Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kamstrup, Maria R., E-mail: mkam0004@bbh.regionh.dk [Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen (Denmark); Gniadecki, Robert [Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen (Denmark); Iversen, Lars [Department of Dermatology, Aarhus University Hospital, Aarhus (Denmark); Skov, Lone [Department of Dermatology, Gentofte Hospital, University of Copenhagen, Copenhagen (Denmark); Petersen, Peter Meidahl [Department of Oncology and Hematology, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Loft, Annika [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Specht, Lena [Department of Oncology and Hematology, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark)

    2015-05-01

    Purpose: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. Methods and Materials: In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over <2.5 weeks, receiving a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. Results: The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. Conclusions: Low-dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT.

  7. Delineating probabilistic species pools in ecology and biogeography

    OpenAIRE

    Karger, Dirk Nikolaus; Cord, Anna F; Kessler, Michael; Kreft, Holger; Kühn, Ingolf; Pompe, Sven; Sandel, Brody; Sarmento Cabral, Juliano; Smith, Adam B; Svenning, Jens-Christian; Tuomisto, Hanna; Weigelt, Patrick; Wesche, Karsten

    2016-01-01

    Aim To provide a mechanistic and probabilistic framework for defining the species pool based on species-specific probabilities of dispersal, environmental suitability and biotic interactions within a specific temporal extent, and to show how probabilistic species pools can help disentangle the geographical structure of different community assembly processes. Innovation Probabilistic species pools provide an improved species pool definition based on probabilities in conjuncti...

  8. Pool water cleaning facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro [Hitachi Ltd., Tokyo (Japan); Asano, Takashi

    1998-05-29

    Only one system comprising a suppression poor water cleaning system (SPCU) and a filtration desalting tower (F/D) is connected for a plurality of nuclear power plants. Pipelines/valves for connecting the one system of the SPCU pump, the F/D and the plurality of nuclear power plants are disposed, and the system is used in common with the plurality of nuclear power plants. Pipelines/valves for connecting a pipeline for passing SP water to the commonly used SPCU pump and a skimmer surge tank are disposed, and fuel pool water is cooled and cleaned by the commonly used SPCU pump and the commonly used F/D. The number of SPCU pumps and the F/D facilities can be reduced, and a fuel pool water cooling operation mode and a fuel pool water cleaning operation mode which were conducted by an FPC pump so far are conducted by the SPCU pump. (N.H.)

  9. Current operating practices of nuclear insurance pools

    International Nuclear Information System (INIS)

    O'Connell, J.M.

    1993-01-01

    This paper discusses the nuclear pooling system and co-operation between the pools, present practice and capacity, with a breakdown of the limits for third party liability and material damage. The author also describes the relationship between the pools and the nuclear operators (the policyholders), and concludes that the nuclear pools have been successful in serving the interests of their member companies, their policyholders and the governments as they have provided a stable insurance market by making available capacity in amounts that had never before been assembled and placed at risk in a single location. 2 tabs

  10. Heat transfer from internally heated hemispherical pools

    International Nuclear Information System (INIS)

    Gabor, J.D.; Ellsion, P.G.; Cassulo, J.C.

    1980-01-01

    Experiments were conducted on heat transfer from internally heated ZnSO 4 -H 2 O pools to the walls of hemispherical containers. This experimental technique provides data for a heat transfer system that has to date been only theoretically treated. Three different sizes of copper hemispherical containers were used: 240, 280, 320 mm in diameter. The pool container served both as a heat transfer surface and as an electrode. The opposing electrode was a copper disk, 50 mm in diameter located at the top of the pool in the center. The top surface of the pool was open to the atmosphere

  11. Effect of turbulent natural convection on sodium pool combustion in the steam generator building of a fast breeder reactor

    International Nuclear Information System (INIS)

    Karthikeyan, S.; Sundararajan, T.; Shet, U.S.P.; Selvaraj, P.

    2009-01-01

    A computational model is proposed to simulate sodium pool combustion considering the effect of turbulent natural convection in a vented enclosure of the steam generator building (SGB) of a fast breeder reactor. The model is validated by comparing the simulated results with the experimental results available in literature for sodium pool combustion in a CSTF vessel. After validation, the effects of vents and the location of the pool on the burning rate of sodium and the associated heat transfer to the walls are studied in an enclosure comparable in size to one floor of the steam generator building. In the presence of ventilation, the burning rate of sodium increases, but the total heat transferred to the walls of the enclosure is reduced. It is also found that the burning rate of sodium pool and the heat transfer to the walls of the enclosures vary significantly with the location of sodium pool.

  12. Cooling device for reactor suppression pool

    International Nuclear Information System (INIS)

    Togasaki, Susumu; Kato, Kiyoshi.

    1994-01-01

    In a cooling device of a reactor suppression pool, when a temperature of pool water is abnormally increased and a heat absorbing portion is heated by, for example, occurrence of an accident, coolants are sent to the outside of the reactor container to actuates a thermally operating portion by the heat energy of coolants and drive heat exchanging fluids of a secondary cooling system. If the heat exchanging fluids are sent to a cooling portion, the coolants are cooled and returned to the heat absorbing portion of the suppression pool water. If the heat absorbing portion is heat pipes, the coolants are evaporated by heat absorbed from the suppression pool water, steams are sent to the thermally operating portion, then coolants are liquefied and caused to return to the heat absorbing portion. If the thermal operation portion is a gas turbine, the gas turbine is operated by the coolants, and it is converted to a rotational force to drive heat exchanging fluids by pumps. By constituting the cooling portion with a condensator, the coolants are condensed and liquefied and returned to the heat absorbing portion of the suppression pool water. (N.H.)

  13. Pool gateway seal

    International Nuclear Information System (INIS)

    Starr, J.A.; Steinert, L.A.

    1983-01-01

    A device for sealing a gateway between interconnectable pools in a nuclear facility comprising a frame supporting a liquid impermeable sheet positioned in a u-shaped gateway between the pools. An inflatable tube carried in a channel in the periphery of the frame and adjoining the gateway provides a seal therebetween when inflated. A restraining arrangement on the bottom edge of the frame is releasably engagable with an adjacent portion of the gateway to restrict the movement of the frame in the u-shaped gateway upon inflation of the tube, thereby enhancing the seal. The impermeable sheet is formed of an elastomer and thus is conformable to a liquid permeable supportive wall upon application of liquid pressure to the side of the sheet opposite the wall

  14. Recent advances in probabilistic species pool delineations

    Directory of Open Access Journals (Sweden)

    Dirk Nikolaus Karger

    2016-07-01

    Full Text Available A species pool is the set of species that could potentially colonize and establish within a community. It has been a commonly used concept in biogeography since the early days of MacArthur and Wilson’s work on Island Biogeography. Despite their simple and appealing definition, an operational application of species pools is bundled with a multitude of problems, which have often resulted in arbitrary decisions and workarounds when defining species pools. Two recently published papers address the operational problems of species pool delineations, and show ways of delineating them in a probabilistic fashion. In both papers, species pools were delineated using a process-based, mechanistical approach, which opens the door for a multitude of new applications in biogeography. Such applications include detecting the hidden signature of biotic interactions, disentangling the geographical structure of community assembly processes, and incorporating a temporal extent into species pools. Although similar in their conclusions, both ‘probabilistic approaches’ differ in their implementation and definitions. Here I give a brief overview of the differences and similarities of both approaches, and identify the challenges and advantages in their application.

  15. Chinese nuclear insurance and Chinese nuclear insurance pool

    International Nuclear Information System (INIS)

    Gong Zhiqi

    2000-01-01

    Chinese Nuclear Insurance Started with Daya Bay Nuclear Power Station, PICC issued the insurance policy. Nuclear insurance cooperation between Chinese and international pool's organizations was set up in 1989. In 1996, the Chinese Nuclear Insurance Pool was prepared. The Chinese Nuclear Insurance Pool was approved by The Chinese Insurance Regulatory Committee in May of 1999. The principal aim is to centralize maximum the insurance capacity for nuclear insurance from local individual insurers and to strengthen the reinsurance relations with international insurance pools so as to provide the high quality insurance service for Chinese nuclear industry. The Member Company of Chinese Nuclear Pool and its roles are introduced in this article

  16. Guide for decontaminating swimming pool at schools

    International Nuclear Information System (INIS)

    Matsuhashi, Shimpei; Kurikami, Hiroshi; Yasuda, Ryo; Takano, Takao; Seko, Noriaki; Naganawa, Hirochika; Kuroki, Ryota; Saegusa, Jun

    2012-07-01

    Because of TEPCO Fukushima Dai-ichi Nuclear Power Plant accident due to the Great East Japan Earthquake, a huge amount of radioactive materials was widely dispersed and precipitated into the environment. Swimming pools in Fukushima prefectures were contaminated with the radioactives. We JAEA carried out several demonstration tests to decontaminate the radioactives and discharge the pool water safely. We concluded the results obtained from the tests as 'Guide for decontaminating Swimming Pool at School' and released it quickly. Following this, we also released the guide in English. This manuscript, as an experimental report of the swimming pool water decontamination, is consisted from the guide in Japanese and English prepared. (author)

  17. Guide for decontaminating swimming pool at schools

    Energy Technology Data Exchange (ETDEWEB)

    Matsuhashi, Shimpei; Kurikami, Hiroshi; Yasuda, Ryo; Takano, Takao; Seko, Noriaki; Naganawa, Hirochika; Kuroki, Ryota; Saegusa, Jun

    2012-07-15

    Because of TEPCO Fukushima Dai-ichi Nuclear Power Plant accident due to the Great East Japan Earthquake, a huge amount of radioactive materials was widely dispersed and precipitated into the environment. Swimming pools in Fukushima prefectures were contaminated with the radioactives. We JAEA carried out several demonstration tests to decontaminate the radioactives and discharge the pool water safely. We concluded the results obtained from the tests as 'Guide for decontaminating Swimming Pool at School' and released it quickly. Following this, we also released the guide in English. This manuscript, as an experimental report of the swimming pool water decontamination, is consisted from the guide in Japanese and English prepared. (author)

  18. (Important hygienic aspects for swimming pools (author's transl))

    Energy Technology Data Exchange (ETDEWEB)

    Somosi, G

    1981-01-01

    The major epidemics which occurred in Hungary and originated from water in swimming pools are reported. The difficulties encountered in producing epidemiological evidence and in monitoring infections originating from water in swimming pools are mentioned. The possibilities of controlling the water quality in swimming pools and of preventing infections are discussed. Reference is made to the existing bacteriological limit values in Hungary to be observed in the recirculation of water in swimming pools.

  19. Studies of thermal stratification in water pool

    International Nuclear Information System (INIS)

    Verma, P.K.; Chandraker, D.K.; Nayak, A.K.; Vijayan, P.K.

    2015-01-01

    Large water pools are used as a heat sink for various cooling systems used in industry. In context of advance nuclear reactors like AHWR, it is used as ultimate heat sink for passive systems for decay heat removal and containment cooling. This system incorporates heat exchangers submerged in the large water pool. However, heat transfer by natural convection in pool poses a problem of thermal stratification. Due to thermal stratification hot layers of water accumulate over the relatively cold one. The heat transfer performance of heat exchanger gets deteriorated as a hot fluid envelops it. In the nuclear reactors, the walls of the pool are made of concrete and it may subject to high temperature due to thermal stratification which is not desirable. In this paper, a concept of employing shrouds around the heat source is studied. These shrouds provide a bulk flow in the water pool, thereby facilitating mixing of hot and cold fluid, which eliminate stratification. The concept has been applied to the a scaled model of Gravity Driven Water Pool (GDWP) of AHWR in which Isolation Condensers (IC) tubes are submerged for decay heat removal of AHWR using ICS and thermal stratification phenomenon was predicted with and without shrouds. To demonstrate the adequacy of the effectiveness of shroud arrangement and to validate the simulation methodology of RELAP5/Mod3.2, experiments has been conducted on a scaled model of the pool with and without shroud. (author)

  20. Thermal analyses of solar swimming pool heating in Pakistan

    International Nuclear Information System (INIS)

    Ahmad, I.

    2011-01-01

    Hotels and swimming clubs in Pakistan pay huge gas bills for heating Swimming pools in winter. Winter days in most parts of Pakistan remain sunny and unglazed low cost solar collectors may be used to extend the swimming season. Installing the pool in a wind-protected area, which receives unobstructed solar radiation, may further reduce the size of the solar collectors required to heat the swimming pools. The pools should be covered with plastic sheet to eliminate evaporative heat losses and to prevent dust and tree leaves falling in the pool. The results of the thermal analysis show that in some parts of the country, a solar exposed pool can maintain comfortable temperature simply by using a plastic sheet on the pool surface. On the other hand, there are cities where solar collector array equal to twice the surface area of the pool is required to keep desired temperature in winter. (author)

  1. Reduction of the pool-top radiation level in HANARO

    International Nuclear Information System (INIS)

    Lee, Choong-Sung; Park, Sang-Jun; Kim, Heonil; Park, Yong-Chul; Choi, Young-San

    1999-01-01

    HANARO is an open-tank-in-pool type reactor. Pool water is the only shielding to minimize the pool top radiation level. During the power ascension test of HANARO, the measured pool top radiation level was higher than the design value because some of the activation products in the coolant reached the pool surface. In order to suppress this rising coolant, the hot water layer system (HWL) was designed and installed to maintain l.2 meter-deep hot water layer whose temperature is 5degC higher than that of the underneath pool surface. After the installation of the HWL system, however, the radiation level of the pool-top did not satisfy the design value. The operation modes of the hot water layer system and the other systems in the reactor pool, which had an effect on the formation of the hot water layer, were changed to reduce pool-top radiation level. After the above efforts, the temperature and the radioactivity distribution in the pool was measured to confirm whether this system blocked the rising coolant. The radiation level at the pool-top was significantly reduced below one tenth of that before installing the HWL and satisfied the design value. It was also confirmed by calculation that this hot water layer system would significantly reduce the release of fission gases to the reactor hall and the environment during the hypothetical accident as well. (author)

  2. 17 CFR 4.22 - Reporting to pool participants.

    Science.gov (United States)

    2010-04-01

    ..., the financial statements are not required to include consolidated information for all series. (7) For... event that the International Financial Reporting Standards require consolidated financial statements for... reporting pool's consolidated financial statements. (ii) The commodity pool operator of a pool that meets...

  3. Cardiothoracic ratio for prediction of left ventricular dilation: a systematic review and pooled analysis.

    Science.gov (United States)

    Loomba, Rohit S; Shah, Parinda H; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit

    2015-03-01

    Increased cardiothoracic ratio noted on chest radiographs often prompts concern and further evaluation with additional imaging. This study pools available data assessing the utility of cardiothoracic ratio in predicting left ventricular dilation. A systematic review of the literature was conducted to identify studies comparing cardiothoracic ratio by chest x-ray to left ventricular dilation by echocardiography. Electronic databases were used to identify studies which were then assessed for quality and bias, with those with adequate quality and minimal bias ultimately being included in the pooled analysis. The pooled data were used to determine the sensitivity, specificity, positive predictive value and negative predictive value of cardiomegaly in predicting left ventricular dilation. A total of six studies consisting of 466 patients were included in this analysis. Cardiothoracic ratio had 83.3% sensitivity, 45.4% specificity, 43.5% positive predictive value and 82.7% negative predictive value. When a secondary analysis was conducted with a pediatric study excluded, a total of five studies consisting of 371 patients were included. Cardiothoracic ratio had 86.2% sensitivity, 25.2% specificity, 42.5% positive predictive value and 74.0% negative predictive value. Cardiothoracic ratio as determined by chest radiograph is sensitive but not specific for identifying left ventricular dilation. Cardiothoracic ratio also has a strong negative predictive value for identifying left ventricular dilation.

  4. Behavior of spent nuclear fuel in water pool storage

    International Nuclear Information System (INIS)

    Johnson, A.B. Jr.

    1977-09-01

    Storage of irradiated nuclear fuel in water pools (basins) has been standard practice since nuclear reactors first began operation approximately 34 years ago. Pool storage is the starting point for all other fuel storage candidate processes and is a candidate for extended interim fuel storage until policy questions regarding reprocessing and ultimate disposal have been resolved. This report assesses the current performance of nuclear fuel in pool storage, the range of storage conditions, and the prospects for extending residence times. The assessment is based on visits to five U.S. and Canadian fuel storage sites, representing nine storage pools, and on discussions with operators of an additional 21 storage pools. Spent fuel storage experience from British pools at Winfrith and Windscale and from a German pool at Karlsruhe (WAK) also is summarized

  5. Design of the Demineralized Water Make-up Line to Maintain the Normal Pool Water Level of the Reactor Pool in the Research Reactor

    International Nuclear Information System (INIS)

    Yoon, Hyun Gi; Choi, Jung Woon; Yoon, Ju Hyeon; Chi, Dae Young

    2012-01-01

    In many research reactors, hot water layer system (HWLS) is used to minimize the pool top radiation level. Reactor pool divided into the hot water layer at the upper part of pool and the cold part below the hot water layer with lower temperature during normal operation. Water mixing between these layers is minimized because the hot water layer is formed above cold water. Therefore the hot water layer suppresses floatation of cold water and reduces the pool top radiation level. Pool water is evaporated form the surface to the building hall because of high temperature of the hot water layer; consequently the pool level is continuously fallen. Therefore, make-up water is necessary to maintain the normal pool level. There are two way to supply demineralized water to the pool, continuous and intermittent methods. In this system design, the continuous water make-up method is adopted to minimize the disturbance of the reactor pool flow. Also, demineralized water make-up is connected to the suction line of the hot water layer system to raise the temperature of make-up water. In conclusion, make-up demineralized water with high temperature is continuously supplied to the hot water layer in the pool

  6. Condensation in a two-phase pool

    International Nuclear Information System (INIS)

    Duffey, R.B.; Hughes, E.D.

    1991-01-01

    We consider the case of vapor condensation in a liquid pool, when the heat transfer is controlled by heat losses through the walls. The analysis is based on drift flux theory for phase separation in the pool, and determines the two-phase mixture height for the pool. To our knowledge this is the first analytical treatment of this classic problem that gives an explicit result, previous work having established the result for the evaporative case. From conservation of mass and energy in a one-dimensional steady flow, together with a void relation between the liquid and vapor fluxes, we determine the increase in the mixture level from the base level of the pool. It can be seen that the thermal and hydrodynamic influences are separable. Thus, the thermal influence of the wall heat transfer appears through its effect on the condensing length L*, so that at high condensation rates the pool is all liquid, and at low rates overflows (the level swell or foaming effect). Similarly, the phase separation effect hydrodynamically determines the height via the relative velocity of the mixture to the entering flux. We examine some practical applications of this result to level swell in condensing flows, and also examine some limits in ideal cases

  7. Welding pool measurement using thermal array sensor

    Science.gov (United States)

    Cho, Chia-Hung; Hsieh, Yi-Chen; Chen, Hsin-Yi

    2015-08-01

    Selective laser melting (SLM) is an additive manufacturing (AM) technology that uses a high-power laser beam to melt metal powder in chamber of inert gas. The process starts by slicing the 3D CAD data as a digital information source into layers to create a 2D image of each layer. Melting pool was formed by using laser irradiation on metal powders which then solidified to consolidated structure. In a selective laser melting process, the variation of melt pool affects the yield of a printed three-dimensional product. For three dimensional parts, the border conditions of the conductive heat transport have a very large influence on the melt pool dimensions. Therefore, melting pool is an important behavior that affects the final quality of the 3D object. To meet the temperature and geometry of the melting pool for monitoring in additive manufacturing technology. In this paper, we proposed the temperature sensing system which is composed of infrared photodiode, high speed camera, band-pass filter, dichroic beam splitter and focus lens. Since the infrared photodiode and high speed camera look at the process through the 2D galvanometer scanner and f-theta lens, the temperature sensing system can be used to observe the melting pool at any time, regardless of the movement of the laser spot. In order to obtain a wide temperature detecting range, 500 °C to 2500 °C, the radiation from the melting pool to be measured is filtered into a plurality of radiation portions, and since the intensity ratio distribution of the radiation portions is calculated by using black-body radiation. The experimental result shows that the system is suitable for melting pool to measure temperature.

  8. A skeleton for distributed work pools in Eden

    DEFF Research Database (Denmark)

    Dieterle, Mischa; Berthold, Jost; Loogen, Rita

    2010-01-01

    We present a flexible skeleton for implementing distributed work pools in our parallel functional language Eden. The skeleton manages a pool of tasks (work pool) in a distributed manner using a demand-driven work stealing approach for load balancing. All coordination is done locally within...

  9. Sustainability of common pool resources

    OpenAIRE

    Timilsina, Raja Rajendra; Kotani, Koji; Kamijo, Yoshio

    2017-01-01

    Sustainability has become a key issue in managing natural resources together with growing concerns for capitalism, environmental and resource problems. We hypothesize that the ongoing modernization of competitive societies, which we refer to as "capitalism," affects human nature for utilizing common pool resources, thus compromising sustainability. To test this hypothesis, we design and implement a set of dynamic common pool resource games and experiments in the following two types of Nepales...

  10. The Nuclear Insurance Pools: Operations and Covers

    International Nuclear Information System (INIS)

    Tetley, M.

    2008-01-01

    Nuclear insurance pools have provided insurance for the nuclear industry for over fifty years and it is fair to say that the development of civil nuclear power would not have been possible without the support of the commercial insurance market. The unknown risks presented by the nascent nuclear power industry in the 1950s required a leap of faith by insurers who developed specialist pooled insurance capacity to ensure adequate capacity to back up the operators' compensation obligations. Since then, nuclear insurance pools have evolved to become comprehensive suppliers of most types of insurance for nuclear plant globally. This paper will outline the structure, development, products and current operations of nuclear insurance pools.(author)

  11. Disinfection of herbal spa pool using combined chlorine dioxide and sodium hypochlorite treatment.

    Science.gov (United States)

    Hsu, Ching-Shan; Huang, Da-Ji

    2015-02-01

    The presence of pathogenic microorganisms in public spa pools poses a serious threat to human health. The problem is particularly acute in herbal spas, in which the herbs and microorganisms may interact and produce undesirable consequences. Accordingly, the present study investigated the effectiveness of a combined disinfectant containing chlorine dioxide and sodium hypochlorite in improving the water quality of a public herbal spa in Taiwan. Water samples were collected from the spa pool and laboratory tests were then performed to measure the variation over time of the microorganism content (total CFU and total coliforms) and residual disinfectant content given a single disinfection mode (SDM) with disinfectant concentrations of 5.2 × 10, 6.29 × 10, 7.4 × 10, and 11.4 × 10(-5) N, respectively. Utilizing the experience gained from the laboratory tests, a further series of on-site investigations was performed using three different disinfection modes, namely SDM, 3DM (once every 3 h disinfection mode), and 2DM (once every 2 h disinfection mode). The laboratory results showed that for all four disinfectant concentrations, the CFU concentration reduced for the first 6 h following SDM treatment, but then increased. Moreover, the ANOVA results showed that the sample treated with the highest disinfectant concentration (11.4 × 10(-5) N) exhibited the lowest rate of increase in the CFU concentration. In addition, the on-site test results showed that 3DM and 2DM treatments with disinfectant concentrations in excess of 9.3 × 10 and 5.5 × 10(-5) N, respectively, provided an effective reduction in the total CFU concentration. In conclusion, the experimental results presented in this study provide a useful source of reference for spa businesses seeking to improve the water quality of their spa pools.

  12. New pool boiling data for water with copper-foam metal at sub-atmospheric pressures: Experiments and correlation

    Energy Technology Data Exchange (ETDEWEB)

    Choon, Ng Kim; Chakraborty, Anutosh; Aye, Sai Maung; Xiaolin, Wang [Department of Mechanical Engineering, National University of Singapore, 10 Kent Ridge Crescent, Singapore 119260 (Singapore)

    2006-08-15

    Over the past decades, pool boiling heat transfer of water has been investigated extensively by many scientists and researchers at system pressures varying from atmospheric to near critical pressure. However, at sub-atmospheric pressures conditions there is a dearth of data, particularly when the vapour pressures are less than 10kPa. The authors have conducted a detailed study of pool boiling of water in an evaporator where its system pressure was about 1.8kPa. The heat flux for pool boiling was derived from an uniform radiant heaters up to 5W/cm{sup 2} (or a total heating rate of 125W within an area of 25cm{sup 2}), a region that is of interest for the cooling of CPUs. (author)

  13. Shedding Light on Dark Liquidity Pools

    NARCIS (Netherlands)

    Degryse, H.A.; van Achter, M.; Wuyts, G.

    2008-01-01

    This article reviews the recent developments on dark liquidity pools starting from the theoretical and empirical academic literature. The number of dark liquidity pools as well as their trading volume has grown substantially in the last couple of years. We highlight the incentives of providers as

  14. NACUBO's Guide to Unitizing Investment Pools. Second Edition

    Science.gov (United States)

    Wheeler, Mary S.

    2011-01-01

    The National Association of College and University Business Officers' (NACUBO's) "Guide to Unitizing Investment Pools" addresses the principles and concepts for administering a consolidated investment pool. Unitization is the mechanism by which investment funds are pooled to maximize investment efficiencies and provide information for donors,…

  15. Fire in the Brazilian Amazon : 3. Dynamics of biomass, C, and nutrient pools in regenerating forests.

    Science.gov (United States)

    Hughes, R F; Kauffman, J B; Cummings, D L

    2000-09-01

    Regenerating forests have become a common land-cover type throughout the Brazilian Amazon. However, the potential for these systems to accumulate and store C and nutrients, and the fluxes resulting from them when they are cut, burned, and converted back to croplands and pastures have not been well quantified. In this study, we quantified pre- and post-fire pools of biomass, C, and nutrients, as well as the emissions of those elements, at a series of second- and third-growth forests located in the states of Pará and Rondônia, Brazil. Total aboveground biomass (TAGB) of second- and third-growth forests averaged 134 and 91 Mg ha -1 , respectively. Rates of aboveground biomass accumulation were rapid in these systems, but were not significantly different between second- and third-growth forests, ranging from 9 to 16 Mg ha -1 year -1 . Residual pools of biomass originating from primary forest vegetation accounted for large portions of TAGB in both forest types and were primarily responsible for TAGB differences between the two forest types. In second-growth forests this pool (82 Mg ha -1 ) represented 58% of TAGB, and in third-growth forests (40 Mg ha -1 ) it represented 40% of TAGB. Amounts of TAGB consumed by burning of second- and third-growth forests averaged 70 and 53 Mg ha -1 , respectively. Aboveground pre-fire pools in second- and third-growth forests averaged 67 and 45 Mg C ha -1 , 821 and 707 kg N ha -1 , 441 and 341 kg P ha -1 , and 46 and 27 kg Ca ha -1 , respectively. While pre-fire pools of C, N, S and K were not significantly different between second- and third-growth forests, pools of both P and Ca were significantly higher in second-growth forests. This suggests that increasing land use has a negative impact on these elemental pools. Site losses of elements resulting from slashing and burning these sites were highly variable: losses of C ranged from 20 to 47 Mg ha -1 ; N losses ranged from 306 to 709 kg ha -1 ; Ca losses ranged from 10 to 145 kg ha -1

  16. Investigation of the condition of spent-fuel pool components

    International Nuclear Information System (INIS)

    Kustas, F.M.; Bates, S.O.; Opitz, B.E.; Johnson, A.B. Jr.; Perez, J.M. Jr.; Farnsworth, R.K.

    1981-09-01

    It is currently projected that spent nuclear fuel, which is discharged from the reactor and then stored in water pools, may remain in those pools for several decades. Other studies have addressed the expected integrity of the spent fuel during extended water storage; this study assesses the integrity of metallic spent fuel pool components. Results from metallurgical examinations of specimens taken from stainless steel and aluminum components exposed in spent fuel pools are presented. Licensee Event Reports (LERs) relating to problems with spent fuel components were assessed and are summarized to define the types of operational problems that have occurred. The major conclusions of this study are: aluminum and stainless steel spent fuel pool components have a good history of performance in both deionized and borated water pools. Although some operational problems involving pool components have occurred, these problems have had minimal impacts

  17. Investigation of the condition of spent-fuel pool components

    Energy Technology Data Exchange (ETDEWEB)

    Kustas, F.M.; Bates, S.O.; Opitz, B.E.; Johnson, A.B. Jr.; Perez, J.M. Jr.; Farnsworth, R.K.

    1981-09-01

    It is currently projected that spent nuclear fuel, which is discharged from the reactor and then stored in water pools, may remain in those pools for several decades. Other studies have addressed the expected integrity of the spent fuel during extended water storage; this study assesses the integrity of metallic spent fuel pool components. Results from metallurgical examinations of specimens taken from stainless steel and aluminum components exposed in spent fuel pools are presented. Licensee Event Reports (LERs) relating to problems with spent fuel components were assessed and are summarized to define the types of operational problems that have occurred. The major conclusions of this study are: aluminum and stainless steel spent fuel pool components have a good history of performance in both deionized and borated water pools. Although some operational problems involving pool components have occurred, these problems have had minimal impacts.

  18. Analysis of the loss of pool cooling accident in a PWR spent fuel pool with MAAP5

    International Nuclear Information System (INIS)

    Wu, Xiaoli; Li, Wei; Zhang, Yapei; Tian, Wenxi; Su, Guanghui; Qiu, Suizheng

    2014-01-01

    Highlights: • A PWR spent fuel pool was modeled by using MAAP5. • Loss of pool cooling severe accident scenarios were studied. • Loss of pool cooling accidents with two mitigation measures were analyzed. - Abstract: The Fukushima Daiichi nuclear accident shows that it is necessary to study potential severe accidents and corresponding mitigation measures for the spent fuel pool (SFP) of a nuclear power plant (NPP). This paper presents the analysis of loss of pool cooling accident scenarios and the discussion of mitigation measures for the SFP at a pressurized water reactor (PWR) NPP with the MAAP5 code. Analysis of uncompensated loss of water due to the loss of pool cooling with different initial pool water levels of 12.2 m (designated as a reference case) and 10.7 m have been performed based on a MAAP5 input model. Scenarios of the accident such as overheating of uncovered fuel assemblies, oxidation of claddings and hydrogen generation, loss of intactness of fuel rod claddings, and release of radioactive fission products were predicted with the assumption that mitigation measures were unavailable. The results covered a broad spectrum of severe accident evaluations in the SFP. Furthermore, as important mitigation measures, the effects of recovering the SFP cooling system and makeup water in SFP on the accident progressions have also been investigated respectively based on the events of pool water boiling and spent fuels uncovery. Based upon the reference case, three cases with the recovery of SFP cooling system and three other cases with makeup water in SFP have been studied. The results showed that, severe accident might happen if SFP cooling system was not restored timely before the spent fuels started to become uncovered; spent fuels could be completely submerged and severe accident might be avoided if SFP makeup water system provided water with a mass flow rate larger than the average evaporation rate defined as the division of pool water mass above the

  19. Sample pooling for real-time PCR detection and virulence determination of the footrot pathogen Dichelobacter nodosus.

    Science.gov (United States)

    Frosth, Sara; König, Ulrika; Nyman, Ann-Kristin; Aspán, Anna

    2017-09-01

    Dichelobacter nodosus is the principal cause of ovine footrot and strain virulence is an important factor in disease severity. Therefore, detection and virulence determination of D. nodosus is important for proper diagnosis of the disease. Today this is possible by real-time PCR analysis. Analysis of large numbers of samples is costly and laborious; therefore, pooling of individual samples is common in surveillance programs. However, pooling can reduce the sensitivity of the method. The aim of this study was to develop a pooling method for real-time PCR analysis that would allow sensitive detection and simultaneous virulence determination of D. nodosus. A total of 225 sheep from 17 flocks were sampled using ESwabs within the Swedish Footrot Control Program in 2014. Samples were first analysed individually and then in pools of five by real-time PCR assays targeting the 16S rRNA and aprV2/B2 genes of D. nodosus. Each pool consisted of four negative and one positive D. nodosus samples with varying amounts of the bacterium. In the individual analysis, 61 (27.1%) samples were positive in the 16S rRNA and the aprV2/B2 PCR assays and 164 (72.9%) samples were negative. All samples positive in the aprV2/B2 PCR-assay were of aprB2 variant. The pooled analysis showed that all 41 pools were also positive for D. nodosus 16S rRNA and the aprB2 variant. The diagnostic sensitivity for pooled and individual samples was therefore similar. Our method includes concentration of the bacteria before DNA-extraction. This may account for the maintenance of diagnostic sensitivity. Diagnostic sensitivity in the real-time PCR assays of the pooled samples were comparable to the sensitivity obtained for individually analysed samples. Even sub-clinical infections were able to be detected in the pooled PCR samples which is important for control of the disease. This method may therefore be implemented in footrot control programs where it can replace analysis of individual samples.

  20. Swimming-pool piles; Piles piscines

    Energy Technology Data Exchange (ETDEWEB)

    Trioulaire, M [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In France two swimming-pool piles, Melusine and Triton, have just been set in operation. The swimming-pool pile is the ideal research tool for neutron fluxes of the order of 10{sup 13}. This type of pile can be of immediate interest to many research centres, but its cost must be reduced and a break with tradition should be observed in its design. It would be an advantage: - to bury the swimming-pool; - to reject the experimental channel; - to concentrate the cooling circuit in the swimming-pool; - to carry out all manipulations in the water; - to double the core. (author) [French] En France, deux piles piscines, Melusine et Triton, viennent d'entrer en service. La pile piscine est l'outil de recherche ideal pour des flux de neutrons de l'ordre de 10{sup 13}. Ce type de pile peut interesser des maintenant de nombreux centres de recherches mais il faut reduire son prix de revient et rompre avec le conformisme de sa conception. Il y a avantage: - a enterrer la piscine; - a supprimer les canaux experimentaux; - a concentrer le circuit de refrigeration dans la piscine; - a effectuer toutes les manipulations dans l'eau; - a doubler le coeur. (auteur)

  1. Plant diversity associated with pools in natural and restored peatlands

    Directory of Open Access Journals (Sweden)

    N. Fontaine

    2007-06-01

    Full Text Available This study describes plant assemblages associated with the edges of peatland pools. We conducted inventories in six natural peatlands in the province of Québec (Canada in order to measure the contribution of pools to species diversity in climatic regions where peatlands are used for peat extraction. We also carried out vegetation surveys in a peatland that has been restored after peat extraction/harvesting to determine whether pool vegetation establishes along the edges of created pools when dry surface restoration techniques only are used. Pools enhanced plant species richness in natural peatlands. Around created pools, species associated with natural pools were still absent, and non-bog species were present, six years after restoration. On this basis, we emphasise the importance of preserving natural peatlands with pools. In order to restore fully the plant diversity associated with peatlands at harvested sites, it may be necessary to modify pool excavation techniques so that created pools resemble more closely those in natural peatlands. Active introduction of the plant species or communities associated with natural pools may also be needed; candidate species for North America include Andromeda glaucophylla, Cladopodiella fluitans, Carex limosa, Eriophorum virginicum, Rhynchospora alba and Sphagnum cuspidatum.

  2. Application of pooled genotyping to scan candidate regions for association with HDL cholesterol levels

    Directory of Open Access Journals (Sweden)

    Hinds David A

    2004-11-01

    Full Text Available Abstract Association studies are used to identify genetic determinants of complex human traits of medical interest. With the large number of validated single nucleotide polymorphisms (SNPs currently available, two limiting factors in association studies are genotyping capability and costs. Pooled DNA genotyping has been proposed as an efficient means of screening SNPs for allele frequency differences in case-control studies and for prioritising them for subsequent individual genotyping analysis. Here, we apply quantitative pooled genotyping followed by individual genotyping and replication to identify associations with human serum high-density lipoprotein (HDL cholesterol levels. The DNA from individuals with low and high HDL cholesterol levels was pooled separately, each pool was amplified by polymerase chain reaction in triplicate and each amplified product was separately hybridised to a high-density oligonucleotide array. Allele frequency differences between case and control groups with low and high HDL cholesterol levels were estimated for 7,283 SNPs distributed across 71 candidate gene regions spanning a total of 17.1 megabases. A novel method was developed to take advantage of independently derived haplotype map information to improve the pooled estimates of allele frequency differences. A subset of SNPs with the largest estimated allele frequency differences between low and high HDL cholesterol groups was chosen for individual genotyping in the study population, as well as in a separate replication population. Four SNPs in a single haplotype block within the cholesteryl ester transfer protein (CETP gene interval were significantly associated with HDL cholesterol levels in both populations. Our study is among the first to demonstrate the application of pooled genotyping followed by confirmation with individual genotyping to identify genetic determinants of a complex trait.

  3. Grundfoss: Chlorination of Swimming Pools

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Hogan, John; Andreassen, Viggo

    1998-01-01

    Grundfos asked for a model, describing the problem of mixing chemicals, being dosed into water systems, to be developed. The application of the model should be dedicated to dosing aqueous solution of chlorine into swimming pools.......Grundfos asked for a model, describing the problem of mixing chemicals, being dosed into water systems, to be developed. The application of the model should be dedicated to dosing aqueous solution of chlorine into swimming pools....

  4. Livestock Grazing as a Driver of Vernal Pool Ecohydrology

    Science.gov (United States)

    Michaels, J.; McCarten, N. F.

    2017-12-01

    Vernal pools are seasonal wetlands that host rare plant communities of high conservation priority. Plant community composition is largely driven by pool hydroperiod. A previous study found that vernal pools grazed by livestock had longer hydroperiods compared with pools excluded from grazing for 10 years, and suggests that livestock grazing can be used to protect plant diversity. It is important to assess whether observed differences are due to the grazing or due to water balance variables including upland discharge into or out of the pools since no a priori measurements were made of the hydrology prior to grazing. To address this question, in 2016 we compared 15 pools that have been grazed continuously and 15 pools that have been fenced off for over 40 years at a site in Sacramento County. We paired pools based on abiotic characteristics (size, shape, slope, soil type) to minimize natural variation. We sampled vegetation and water depth using Solinst level loggers. We found that plant diversity and average hydroperiod was significantly higher in the grazed pools. We are currently measuring groundwater connectivity and upland inputs in order to compare the relative strength of livestock grazing as a driver of hydroperiod to these other drivers.

  5. The Role of Nuclear Insurance Pools

    International Nuclear Information System (INIS)

    Reitsma, S. M. S.

    2006-01-01

    Since fifty years insurers respond to the need of both governments and the electricity industry to provide financial protection to cover the perils presented by the use of nuclear energy for peaceful purposes. This paper aims at explaining what difficulties had to be solved in order to enable insurers to provide such protection, that as a solution to these difficulties Nuclear Insurance Pools were formed, how such pools operate and what security they provide. Thereby not only a number of universal principles underlying nuclear pool insurance will be explained, but also some differences in the characteristics of such insurance per group of countries. (author)

  6. Natural convection heat transfer in a rectangular pool with volumetric heat sources

    International Nuclear Information System (INIS)

    Lee, Seung Dong; Lee, Kang Hee; Suh, Kune Y.

    2003-01-01

    Natural convection plays an important role in determining the thermal load from debris accumulated in the reactor vessel lower head during a severe accident. The heat transfer within the molten core material can be characterized by buoyancy-induced flows resulting from internal heating due to decay of fission products. The thermo-fluid dynamic characteristics of the molten pool depend strongly on the thermal boundary conditions. The spatial and temporal variation of heat flux on the pool wall boundaries and the pool superheat are mainly characterized by the natural convection flow inside the molten pool. In general, natural convection involving internal heat generation is delineated in terms of the modified Rayleigh number, Ra', which quantifies the internal heat source and hence the strength of buoyancy. The test section is of rectangular cavity whose length, width, and height are 500 mm, 80 mm, and 250 mm, respectively. A total of twenty-four T-type thermocouples were installed in the test loop to measure temperature distribution. Four T-type thermocouples were utilized to measure temperatures on the boundary. A direct heating method was adopted in this test to simulate the uniform heat generation. The experiments covered a range of Rayleigh number, Ra, between 4.87x10 7 and 2.32x10 14 and Prandtl number, Pr, between 0.7 and 3.98. Tests were conducted with water and air as simulant. The upper and lower boundary conditions were maintained at a uniform temperature of 10degC. (author)

  7. Swimming Pool Safety

    Science.gov (United States)

    ... Spread the Word Shop AAP Find a Pediatrician Safety & Prevention Immunizations All Around At Home At Play ... Español Text Size Email Print Share Swimming Pool Safety Page Content ​What is the best way to ...

  8. Nuclear Insurance Pools: World-wide Practice and Prospective

    International Nuclear Information System (INIS)

    Reitsma, S. M. S.

    2000-01-01

    The following paper explains why Nuclear Insurance Pools were established, how they operate and what insurance protection they offer to the operations of nuclear installations. It will be shown that the clear interrelationship of the Pool-insurance operations, both on a national and an international level, has resulted in a transparency of each individual Pool-Member's exposure, which enables him to make the highest possible commitment to nuclear risks. Finally, some views will be given as regards the future prospective for the long proven method of pooling this particularly sensitive class of business. (author)

  9. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma: an open clinical study and pooled data analysis.

    Science.gov (United States)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars; Skov, Lone; Petersen, Peter Meidahl; Loft, Annika; Specht, Lena

    2015-05-01

    Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Long-term frequent prescribed fire decreases surface soil carbon and nitrogen pools in a wet sclerophyll forest of Southeast Queensland, Australia.

    Science.gov (United States)

    Muqaddas, Bushra; Zhou, Xiaoqi; Lewis, Tom; Wild, Clyde; Chen, Chengrong

    2015-12-01

    Prescribed fire is one of the most widely-used management tools for reducing fuel loads in managed forests. However the long-term effects of repeated prescribed fires on soil carbon (C) and nitrogen (N) pools are poorly understood. This study aimed to investigate how different fire frequency regimes influence C and N pools in the surface soils (0-10 cm). A prescribed fire field experiment in a wet sclerophyll forest established in 1972 in southeast Queensland was used in this study. The fire frequency regimes included long unburnt (NB), burnt every 2 years (2yrB) and burnt every 4 years (4yrB), with four replications. Compared with the NB treatment, the 2yrB treatment lowered soil total C by 44%, total N by 54%, HCl hydrolysable C and N by 48% and 59%, KMnO4 oxidizable C by 81%, microbial biomass C and N by 42% and 33%, cumulative CO2-C by 28%, NaOCl-non-oxidizable C and N by 41% and 51%, and charcoal-C by 17%, respectively. The 4yrB and NB treatments showed no significant differences for these soil C and N pools. All soil labile, biologically active and recalcitrant and total C and N pools were correlated positively with each other and with soil moisture content, but negatively correlated with soil pH. The C:N ratios of different C and N pools were greater in the burned treatments than in the NB treatments. This study has highlighted that the prescribed burning at four year interval is a more sustainable management practice for this subtropical forest ecosystem. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. 13 CFR 120.1708 - Pool Certificates.

    Science.gov (United States)

    2010-01-01

    ... United States. (c) SBA purchase of a Loan Interest. SBA will determine whether to purchase a Loan... reserves the right to purchase a Loan Interest from a Pool at any time. (d) Self-liquidating. A Pool... market conditions and program experience, and will publish any such change in the Federal Register. (h...

  12. ENERGY SAVING AT OPERATION OF OUTDOOR SWIMMING POOLS

    Directory of Open Access Journals (Sweden)

    V. F. Ivin

    2013-09-01

    Full Text Available Purpose. Energy saving is a major problem in modern power engineering and various energy-consuming devices. They include outdoor swimming pools. In order to maintain them in working condition, especially in winter period, it takes significant amount of thermal energy. Task of heat loss substantial decrease in open swimming pools is considered in the article (on DNURT example. Methodology. The method of determining the mass and heat loss on the basis of criteria equations of heat and mass transfer theory is used. Findings. Calculations of the actual DNURT pool heat loss for different seasons, as for natural convection both for air forced motion above the free water surface are performed. It is shown that for the adiabatic evaporation conditions of water from the pool in winter during blow-off with wind the heat loss can be up to 2 kW/m2 on surface. To reduce these losses it is offered to cover water surface in a pool with a special material with low thermal conductivity on the basis of porous polyethylene during the time when the pool is not used for other purposes. It is shown that the implementation of these standards will reduce the actual heat loss, at least 5-6 times. Originality. The solution of important environmental and energy problem thanks to reducing heat losses by the pool in different times of a year and correspondingly lower emissions of power generating enterprises. Practical value. It is shown that the coating surface of the pool with poorly heat-conducting and easy to install coating will let, at a minimum, to reduce the actual heat loss on 5-6 times and reduce the emissions of power plants generating energy for pool heating.

  13. CDC Study Finds Fecal Contamination in Pools

    Science.gov (United States)

    ... Communication (404) 639-3286 CDC study finds fecal contamination in pools A study of public pools done ... The E. coli is a marker for fecal contamination. Finding a high percentage of E. coli-positive ...

  14. Sediment transport through self-adjusting, bedrock-walled waterfall plunge pools

    Science.gov (United States)

    Scheingross, Joel S.; Lamb, Michael P.

    2016-05-01

    Many waterfalls have deep plunge pools that are often partially or fully filled with sediment. Sediment fill may control plunge-pool bedrock erosion rates, partially determine habitat availability for aquatic organisms, and affect sediment routing and debris flow initiation. Currently, there exists no mechanistic model to describe sediment transport through waterfall plunge pools. Here we develop an analytical model to predict steady-state plunge-pool depth and sediment-transport capacity by combining existing jet theory with sediment transport mechanics. Our model predicts plunge-pool sediment-transport capacity increases with increasing river discharge, flow velocity, and waterfall drop height and decreases with increasing plunge-pool depth, radius, and grain size. We tested the model using flume experiments under varying waterfall and plunge-pool geometries, flow hydraulics, and sediment size. The model and experiments show that through morphodynamic feedbacks, plunge pools aggrade to reach shallower equilibrium pool depths in response to increases in imposed sediment supply. Our theory for steady-state pool depth matches the experiments with an R2 value of 0.8, with discrepancies likely due to model simplifications of the hydraulics and sediment transport. Analysis of 75 waterfalls suggests that the water depths in natural plunge pools are strongly influenced by upstream sediment supply, and our model provides a mass-conserving framework to predict sediment and water storage in waterfall plunge pools for sediment routing, habitat assessment, and bedrock erosion modeling.

  15. The extent of the influence and flux estimation of volatile mercury from the aeration pool in a typical coal-fired power plant equipped with a seawater flue gas desulfurization system

    International Nuclear Information System (INIS)

    Sun, Lumin; Feng, Lifeng; Yuan, Dongxing; Lin, Shanshan; Huang, Shuyuan; Gao, Liangming; Zhu, Yong

    2013-01-01

    Before being discharged, the waste seawater from the flue gas desulfurization system of coal-fired power plants contains a large amount of mercury, and is treated in aeration pools. During this aeration process, part of the mercury enters the atmosphere, but only very limited impact studies concerning this have been carried out. Taking a typical Xiamen power plant as an example, the present study targeted the elemental mercury emitted from the aeration pool. Concentrations of dissolved gaseous mercury as high as 1.14 ± 0.17 ng·L −1 were observed in the surface waste seawater in the aeration pool, and gaseous elemental mercury (GEM) as high as 10.94 ± 1.89 ng·m −3 was found in the air above the pool. To investigate the area affected by this GEM through air transfer, the total mercury in the dust and topsoil samples around the aeration pool were analyzed. Much higher values were found compared to those at a reference site. Environmental factors other than solar radiation had limited influence on the concentrations of the mercury species in the pool. A simulation device was built in our laboratory to study the flux of mercury from the aeration pool into the air. The results showed that more than 0.59 kg of mercury was released from the aeration pool every year, occupying 0.3% of the total mercury in the waste seawater. The transfer of mercury from water to air during the aeration pool and its environmental influence should not be ignored. - Highlights: ► High concentration of volatile mercury was observed in the aeration pool. ► More than 0.3% of total discharged Hg emitted from the pool into the air. ► Higher aeration rate resulted in more mercury emitted into the air. ► The dust and topsoil around the pool were polluted with the mercury

  16. Pool scrubbing and hydrodynamic experiments on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez-Jimenez, J.

    1995-01-01

    Plant analyses have shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination ofboundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanisms acting at the pool entrance. As a consequence, a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei the pool were measured and fitted to a long normal distribution. Particularly, size was found to be quite sensitive to inletgas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major highlights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  17. Pool scrubbing and hydrodynamic experiment on jet injection regime

    Energy Technology Data Exchange (ETDEWEB)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-07-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  18. Pool scrubbing and hydrodynamic experiment on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-01-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  19. Turbulence model for melt pool natural convection heat transfer

    International Nuclear Information System (INIS)

    Kelkar, K.M.; Patankar, S.V.

    1994-01-01

    Under severe reactor accident scenarios, pools of molten core material may form in the reactor core or in the hemispherically shaped lower plenum of the reactor vessel. Such molten pools are internally heated due to the radioactive decay heat that gives rise to buoyant flows in the molten pool. The flow in such pools is strongly influenced by the turbulent mixing because the expected Rayleigh numbers under accidents scenarios are very high. The variation of the local heat flux over the boundaries of the molten pools are important in determining the subsequent melt progression behavior. This study reports results of an ongoing effort towards providing a well validated mathematical model for the prediction of buoyant flow and heat transfer in internally heated pool under conditions expected in severe accident scenarios

  20. Controls on Filling and Evacuation of Sediment in Waterfall Plunge Pools

    Science.gov (United States)

    Scheingross, J. S.; Lamb, M. P.

    2014-12-01

    Many waterfalls are characterized by the presence of deep plunge pools that experience periods of sediment fill and evacuation. These cycles of sediment fill are a first order control on the relative magnitude of lateral versus vertical erosion at the base of waterfalls, as vertical incision requires cover-free plunge pools to expose the bedrock floor, while lateral erosion can occur when pools are partially filled and plunge-pool walls are exposed. Currently, there exists no mechanistic model describing sediment transport through waterfall plunge pools, limiting our ability to predict waterfall retreat. To address this knowledge gap, we performed detailed laboratory experiments measuring plunge-pool sediment transport capacity (Qsc_pool) under varying waterfall and plunge-pool geometries, flow hydraulics, and sediment size. Our experimental plunge-pool sediment transport capacity measurements match well with a mechanistic model we developed which combines existing waterfall jet theory with a modified Rouse profile to predict sediment transport capacity as a function of water discharge and suspended sediment concentration at the plunge-pool lip. Comparing the transport capacity of plunge pools to lower gradient portions of rivers (Qsc_river) shows that, for transport limited conditions, plunge pools fill with sediment under modest water discharges when Qsc_river > Qsc_pool, and empty to bedrock under high discharges when Qsc_pool > Qsc_river. These results are consistent with field observations of sand-filled plunge pools with downstream boulder rims, implying filling and excavation of plunge pools over single-storm timescales. Thus, partial filling of waterfall plunge pools may provide a mechanism to promote lateral undercutting and retreat of waterfalls in homogeneous rock in which plunge-pool vertical incision occurs during brief large floods that expose bedrock, whereas lateral erosion may prevail during smaller events.

  1. Numerical modelling of methanol liquid pool fires

    Science.gov (United States)

    Prasad, Kuldeep; Li, Chiping; Kailasanath, K.; Ndubizu, Chuka; Ananth, Ramagopal; Tatem, P. A.

    1999-12-01

    The focus of this paper is on numerical modelling of methanol liquid pool fires. A mathematical model is first developed to describe the evaporation and burning of a two-dimensional or axisymmetric pool containing pure liquid methanol. Then, the complete set of unsteady, compressible Navier-Stokes equations for reactive flows are solved in the gas phase to describe the convection of the fuel gases away from the pool surface, diffusion of the gases into the surrounding air and the oxidation of the fuel into product species. Heat transfer into the liquid pool and the metal container through conduction, convection and radiation are modelled by solving a modified form of the energy equation. Clausius-Clapeyron relationships are invoked to model the evaporation rate of a two-dimensional pool of pure liquid methanol. The governing equations along with appropriate boundary and interface conditions are solved using the flux-corrected transport algorithm. Numerical results exhibit a flame structure that compares well with experimental observations. Temperature profiles and burning rates were found to compare favourably with experimental data from single- and three-compartment laboratory burners. The model predicts a puffing frequency of approximately 12 Hz for a 1 cm diameter methanol pool in the absence of any air co-flow. It is also observed that increasing the air co-flow velocity helps in stabilizing the diffusion flame, by pushing the vortical structures away from the flame region.

  2. Security cost allocation under combined bilateral-pool market dispatch

    International Nuclear Information System (INIS)

    Abdullah, M.P.; Hassan, M.Y.; Hussin, F.

    2008-01-01

    Most electricity markets around the world are a combination of bilateral and pool markets, such as NordPool and NYPOOL. In these models, market participants bid into the pool and also make bilateral contracts with each other. This paper addressed the issue of congestion management and security cost allocation in a power pool market model. The basic idea of security cost allocation is to divide the incurred security cost due to congestion relief into pool and bilateral market based on their flow contribution to the congested line. A newly proposed security cost allocation strategy of the combined bilateral-pool market was also presented along with case studies using IEEE-14 bus system that tested the proposed method. Using the proposed method, it was shown that security costs are allocated to market participants at different prices which reflect the load contribution to the security problem. This solves the problem of the uniform security cost allocation in a pure pool market system having uniform pricing, and provides a proper security signal to market participants. 11 refs., 3 tabs., 4 figs

  3. Meat intake and cause-specific mortality: a pooled analysis of Asian prospective cohort studies.

    Science.gov (United States)

    Lee, Jung Eun; McLerran, Dale F; Rolland, Betsy; Chen, Yu; Grant, Eric J; Vedanthan, Rajesh; Inoue, Manami; Tsugane, Shoichiro; Gao, Yu-Tang; Tsuji, Ichiro; Kakizaki, Masako; Ahsan, Habibul; Ahn, Yoon-Ok; Pan, Wen-Harn; Ozasa, Kotaro; Yoo, Keun-Young; Sasazuki, Shizuka; Yang, Gong; Watanabe, Takashi; Sugawara, Yumi; Parvez, Faruque; Kim, Dong-Hyun; Chuang, Shao-Yuan; Ohishi, Waka; Park, Sue K; Feng, Ziding; Thornquist, Mark; Boffetta, Paolo; Zheng, Wei; Kang, Daehee; Potter, John; Sinha, Rashmi

    2013-10-01

    Total or red meat intake has been shown to be associated with a higher risk of mortality in Western populations, but little is known of the risks in Asian populations. We examined temporal trends in meat consumption and associations between meat intake and all-cause and cause-specific mortality in Asia. We used ecological data from the United Nations to compare country-specific meat consumption. Separately, 8 Asian prospective cohort studies in Bangladesh, China, Japan, Korea, and Taiwan consisting of 112,310 men and 184,411 women were followed for 6.6 to 15.6 y with 24,283 all-cause, 9558 cancer, and 6373 cardiovascular disease (CVD) deaths. We estimated the study-specific HRs and 95% CIs by using a Cox regression model and pooled them by using a random-effects model. Red meat consumption was substantially lower in the Asian countries than in the United States. Fish and seafood consumption was higher in Japan and Korea than in the United States. Our pooled analysis found no association between intake of total meat (red meat, poultry, and fish/seafood) and risks of all-cause, CVD, or cancer mortality among men and women; HRs (95% CIs) for all-cause mortality from a comparison of the highest with the lowest quartile were 1.02 (0.91, 1.15) in men and 0.93 (0.86, 1.01) in women. Ecological data indicate an increase in meat intake in Asian countries; however, our pooled analysis did not provide evidence of a higher risk of mortality for total meat intake and provided evidence of an inverse association with red meat, poultry, and fish/seafood. Red meat intake was inversely associated with CVD mortality in men and with cancer mortality in women in Asian countries.

  4. Robotic cleaning of a spent fuel pool

    International Nuclear Information System (INIS)

    Roman, H.T.; Marian, F.A.; Silverman, E.B.; Barkley, V.P.

    1987-01-01

    Spent fuel pools at nuclear power plants are not cleaned routinely, other than by purifying the water that they contain. Yet, debris can collect on the bottom of a pool and should be removed prior to fuel transfer. At Public Service Electric and Gas Company's Hope Creek Nuclear Power Plant, a submersible mobile robot - ARD Corporation's SCAVENGER - was used to clean the bottom of the spent fuel pool prior to initial fuel loading. The robotic device was operated remotely (as opposed to autonomously) with a simple forward/reverse control, and it cleaned 70-80% of the pool bottom. This paper reports that a simple cost-benefit analysis shows that the robotic device would be less expensive, on a per mission basis, than other cleaning alternatives, especially if it were used for other similar cleaning operations throughout the plant

  5. Longevity of Wood-Forced Pools in an Old-Growth Forest

    Science.gov (United States)

    Buffington, J. M.; Woodsmith, R. D.; Johnson, A. C.

    2009-12-01

    Wood debris plays an important role in scouring pools in forest channels and providing resultant habitat for aquatic organisms. We investigated the longevity of such pools in a gravel-bed river flowing through old-growth forest in southeastern Alaska by aging trees and “bear’s bread” fungi (Ganoderma applanatum, Fomitopsis pinicola) growing on pool-forming wood debris. Ages were determined by counting annual growth rings from cores and cross sections of trees and fungi growing on the wood debris. These ages are minimum values because they do not account for lag time between debris recruitment and seedling/spore establishment on the debris, nor do they account for flood scour that may periodically reset tree and fungi growth on the debris. The study stream has a gradient of about 1%, bankfull width and depth of 13.3 and 0.78 m, respectively, median grain size of 18 mm, a high wood loading (0.8 pieces/m), and a correspondingly low pool spacing (0.3 bankfull widths/pool), with 81% of the pools forced by wood debris. The size of wood debris in the study stream is large relative to the channel (average log length of 7.6 m and diameter of 0.35 m), rendering most debris immobile. Eighty-one pool-forming pieces of wood were dated over 1.2 km of stream length, with 28% of these pieces causing scour of more than one pool. In all, 122 wood-forced pools were dated, accounting for 38% of all pools at the site and 47% of the wood-forced pools. Fifty-three percent of the wood-forced pools lacked datable wood because these pieces either: were newly recruited; had been scoured by floods; or were contained below the active channel elevation, prohibiting vegetation establishment on the wood debris (the most common cause). The debris age distribution declined exponentially from 2 to 113 yrs., with a median value of 18 yrs. Similar exponential residence time distributions have been reported in other studies, but our analysis focused specifically on the ages of pool-forming wood

  6. Controlling pool depth during VAR of Alloy 718

    Science.gov (United States)

    Lopez, F.; Beaman, J.; Williamson, R.; Evans, D.

    2016-07-01

    A longtime goal of superalloy producers has been to control the geometry of the liquid pool in solidifying ingots. Accurate pool depth control at appropriate values is expected to result in ingots free of segregation defects. This article describes an industrial VAR experiment in which a 430mm (17 in) diameter Alloy 718 electrode was melted into a 510mm (20 in) ingot. In the experiment, the depth of the liquid pool at the mid-radius was controlled to three different set-points: 137 mm (nominal), 193 mm (deep) and 118 mm (shallow). At each level, the pool depth was marked by a power cutback of several minutes. The ingot was sectioned and longitudinal slices were cut out. Analysis of the photographed ingot revealed that accurate control was obtained for both the nominal and deep pool cases, while the third one was not conclusive.

  7. Estimated environmental radionuclide transfer and deposition into outdoor swimming pools

    International Nuclear Information System (INIS)

    Tagami, Kazumi; Nagata, Izumi; Sueki, Keisuke

    2014-01-01

    In 2011, a large radioactive discharge occurred at the Fukushima Daiichi nuclear power plant. This plant is located within a climatically temperate region where outdoor swimming pools are popular. Although it is relatively easy to decontaminate pools by refilling them with fresh water, it is difficult to maintain safe conditions given highly contaminated diurnal dust falls from the surrounding contaminated ground. Our objectives in this paper were to conduct daily radioactivity measurements, to determine the quantity of radioactive contaminants from the surrounding environment that invade outdoor pools, and to investigate the efficacy of traditional pool cleaners in removing radioactive contaminants. The depositions in the paper filterable particulates ranged from 0 to 62,5 Bq/m 2 /day, with the highest levels found in the southern Tohoku District containing Fukushima Prefecture and in the Kanto District containing Tokyo Metro. They were approximately correlated with the ground contamination. Traditional pool cleaners eliminated 99% of contaminants at the bottom of the pool, reducing the concentration to 41 Bq/m 2 after cleaning. Authors recommended the deposition or the blown radionuclides into outdoor swimming pools must be considered into pool regulations when the environments exactly polluted with radionuclides. - Highlights: • Deposition into outdoor swimming pool in a habitable areas estimated 72 Bq/m 2 /day. • More than 500 Bq/m 2 /day deposition will exceed our national guideline (10 Bq/l) of swimming pool. • Vacuum pool cleaner eliminates 99% radionuclides deposition

  8. Macroinvertebrate community assembly in pools created during peatland restoration

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Lee E., E-mail: l.brown@leeds.ac.uk; Ramchunder, Sorain J.; Beadle, Jeannie M.; Holden, Joseph

    2016-11-01

    Many degraded ecosystems are subject to restoration attempts, providing new opportunities to unravel the processes of ecological community assembly. Restoration of previously drained northern peatlands, primarily to promote peat and carbon accumulation, has created hundreds of thousands of new open water pools. We assessed the potential benefits of this wetland restoration for aquatic biodiversity, and how communities reassemble, by comparing pool ecosystems in regions of the UK Pennines on intact (never drained) versus restored (blocked drainage-ditches) peatland. We also evaluated the conceptual idea that comparing reference ecosystems in terms of their compositional similarity to null assemblages (and thus the relative importance of stochastic versus deterministic assembly) can guide evaluations of restoration success better than analyses of community composition or diversity. Community composition data highlighted some differences in the macroinvertebrate composition of restored pools compared to undisturbed peatland pools, which could be used to suggest that alternative end-points to restoration were influenced by stochastic processes. However, widely used diversity metrics indicated no differences between undisturbed and restored pools. Novel evaluations of restoration using null models confirmed the similarity of deterministic assembly processes from the national species pool across all pools. Stochastic elements were important drivers of between-pool differences at the regional-scale but the scale of these effects was also similar across most of the pools studied. The amalgamation of assembly theory into ecosystem restoration monitoring allows us to conclude with more certainty that restoration has been successful from an ecological perspective in these systems. Evaluation of these UK findings compared to those from peatlands across Europe and North America further suggests that restoring peatland pools delivers significant benefits for aquatic fauna by

  9. Macroinvertebrate community assembly in pools created during peatland restoration

    International Nuclear Information System (INIS)

    Brown, Lee E.; Ramchunder, Sorain J.; Beadle, Jeannie M.; Holden, Joseph

    2016-01-01

    Many degraded ecosystems are subject to restoration attempts, providing new opportunities to unravel the processes of ecological community assembly. Restoration of previously drained northern peatlands, primarily to promote peat and carbon accumulation, has created hundreds of thousands of new open water pools. We assessed the potential benefits of this wetland restoration for aquatic biodiversity, and how communities reassemble, by comparing pool ecosystems in regions of the UK Pennines on intact (never drained) versus restored (blocked drainage-ditches) peatland. We also evaluated the conceptual idea that comparing reference ecosystems in terms of their compositional similarity to null assemblages (and thus the relative importance of stochastic versus deterministic assembly) can guide evaluations of restoration success better than analyses of community composition or diversity. Community composition data highlighted some differences in the macroinvertebrate composition of restored pools compared to undisturbed peatland pools, which could be used to suggest that alternative end-points to restoration were influenced by stochastic processes. However, widely used diversity metrics indicated no differences between undisturbed and restored pools. Novel evaluations of restoration using null models confirmed the similarity of deterministic assembly processes from the national species pool across all pools. Stochastic elements were important drivers of between-pool differences at the regional-scale but the scale of these effects was also similar across most of the pools studied. The amalgamation of assembly theory into ecosystem restoration monitoring allows us to conclude with more certainty that restoration has been successful from an ecological perspective in these systems. Evaluation of these UK findings compared to those from peatlands across Europe and North America further suggests that restoring peatland pools delivers significant benefits for aquatic fauna by

  10. Macroinvertebrate community assembly in pools created during peatland restoration.

    Science.gov (United States)

    Brown, Lee E; Ramchunder, Sorain J; Beadle, Jeannie M; Holden, Joseph

    2016-11-01

    Many degraded ecosystems are subject to restoration attempts, providing new opportunities to unravel the processes of ecological community assembly. Restoration of previously drained northern peatlands, primarily to promote peat and carbon accumulation, has created hundreds of thousands of new open water pools. We assessed the potential benefits of this wetland restoration for aquatic biodiversity, and how communities reassemble, by comparing pool ecosystems in regions of the UK Pennines on intact (never drained) versus restored (blocked drainage-ditches) peatland. We also evaluated the conceptual idea that comparing reference ecosystems in terms of their compositional similarity to null assemblages (and thus the relative importance of stochastic versus deterministic assembly) can guide evaluations of restoration success better than analyses of community composition or diversity. Community composition data highlighted some differences in the macroinvertebrate composition of restored pools compared to undisturbed peatland pools, which could be used to suggest that alternative end-points to restoration were influenced by stochastic processes. However, widely used diversity metrics indicated no differences between undisturbed and restored pools. Novel evaluations of restoration using null models confirmed the similarity of deterministic assembly processes from the national species pool across all pools. Stochastic elements were important drivers of between-pool differences at the regional-scale but the scale of these effects was also similar across most of the pools studied. The amalgamation of assembly theory into ecosystem restoration monitoring allows us to conclude with more certainty that restoration has been successful from an ecological perspective in these systems. Evaluation of these UK findings compared to those from peatlands across Europe and North America further suggests that restoring peatland pools delivers significant benefits for aquatic fauna by

  11. Sharing as risk pooling in a social dilemma experiment

    Directory of Open Access Journals (Sweden)

    Todd L. Cherry

    2015-03-01

    Full Text Available In rural economies with missing or incomplete markets, idiosyncratic risk is frequently pooled through informal networks. Idiosyncratic shocks, however, are not limited to private goods but can also restrict an individual from partaking in or benefiting from a collective activity. In these situations, a group must decide whether to provide insurance to the affected member. We describe results of a laboratory experiment designed to test whether a simple sharing institution can sustain risk pooling in a social dilemma with idiosyncratic risk. We tested whether risk could be pooled without a commitment device and, separately, whether effective risk pooling induced greater cooperation in the social dilemma. We found that even in the absence of a commitment device or reputational considerations, subjects voluntarily pooled risk, thereby reducing variance in individual earnings. In spite of effective risk pooling, however, cooperation in the social dilemma was unaffected.

  12. Contribution of maternal thyroxine to fetal thyroxine pools in normal rats near term

    International Nuclear Information System (INIS)

    Morreale de Escobar, G.; Calvo, R.; Obregon, M.J.; Escobar Del Rey, F.

    1990-01-01

    Normal dams were equilibrated isotopically with [ 125 I]T4 infused from 11 to 21 days of gestation, at which time maternal and fetal extrathyroidal tissues were obtained to determine their [ 125 I]T4 and T4 contents. The specific activity of the [ 125 I]T4 in the fetal tissues was lower than in maternal T4 pools. The extent of this change allows evaluation of the net contribution of maternal T4 to the fetal extrathyroidal T4 pools. At 21 days of gestation, near term, this represents 17.5 +/- 0.9% of the T4 in fetal tissues, a value considerably higher than previously calculated. The methodological approach was validated in dams given a goitrogen to block fetal thyroid function. The specific activities of the [ 125 I]T4 in maternal and fetal T4 pools were then similar, confirming that in cases of fetal thyroid impairment the T4 in fetal tissues is determined by the maternal contribution. Thus, previous statements that in normal conditions fetal thyroid economy near term is totally independent of maternal thyroid status ought to be reconsidered

  13. Polychlorinated biphenyl concentrations in pooled serum from people in different age groups from five Chinese cities.

    Science.gov (United States)

    Wang, Qinghua; Yuan, Haodong; Jin, Jun; Li, Peng; Ma, Yulong; Wang, Ying

    2018-05-01

    Polychlorinated biphenyl (PCB) concentrations in human serum samples pooled by donor age and sex (≥60, 50-59, 40-49, 30-39, and 20-29 years old) were determined. The pooled samples were supplied by hospitals in five Chinese cities, which were Yitong (Jilin Province), Weifang (Shandong Province), Ganzi (Sichuan Province), Huaihua (Hunan Province), and Lingshui (Hainan Province). The total PCB concentrations were relatively low compared with concentrations that have been found in other parts of the world. Pentachlorobiphenyls were the dominant PCBs. The total PCB concentrations and the concentrations of most of the pentachlorobiphenyl congeners were slightly higher in the samples from younger donors than in the samples from older donors. The results indicated there is a new source of PCBs in China. Heptachlorobiphenyls in Lingshui may have been transported from Vietnam. Statistical analysis showed that young and old people had been exposed to different sources of PCBs. PCB 126 contributed more than the other dioxin-like PCBs to the total toxic equivalents when the samples were examined as a whole or by city, and the total toxic equivalents were higher in younger people than in older people for the whole sample set and for the Yitong samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Opportunities and challenges when pooling milk samples using ELISA

    DEFF Research Database (Denmark)

    Græsbøll, Kaare; Andresen, Lars Ole; Hisham Beshara Halasa, Tariq

    2017-01-01

    -positive samples by pooling. To illustrate this, the sensitivity of antibody ELISA on pooled samples of bovine milk for Salmonella Dublin, Mycobacterium avium spp. paratuberculosis, and bovine virus diarrhea was tested. For these milk assays, the analytical sensitivity decreased rapidly with increasing pool sizes...

  15. Microscopic bubble behaviour in suppression pool during wetwell venting

    Science.gov (United States)

    Zablackaite, G.; Nagasaka, H.; Kikura, H.

    2017-10-01

    During a severe accident PCV failure should be avoided and fission products inside PCV should be confined as much as possible. In order to minimize FPs release, Wetwell venting is conducted by releasing steam-non-condensable gas mixture carrying FPs from the Drywell to Suppression Pool. Steam is condensed by subcooled water in the pool, and most of FPs are retained into water. The removal of FP in the water pool is referred to as “Pool Scrubbing effect”. Hydrodynamic parameters of bubbles have impact on pool scrubbing effect. However, there is only few data available to evaluate quantitatively the bubble behaviour under depressurization and/or thermal stratification conditions. Series of experiments were conducted to evaluate the influence of temperature distribution, non-condensable gas content and pressure in the Wetwell on bubble behaviour. Bubbles were visualized using High Speed Camera and adopting shadowgraphy technique. Applying Particle Tracking Velocimetry, bubble velocity and size distribution were obtained from recorded images. Experimental results show that with increasing suppression pool temperature, bubbles reaching the pool surface decreased in size and traveling velocity became slower. In pressurized wetwell, bubble behaviour was similar to that in the heated up suppression pool case, although bubble parameters were similar to the low temperature case. Higher air content induced water surface movement and bubbles were smaller due to break up.

  16. Sequencing of BAC pools by different next generation sequencing platforms and strategies

    Directory of Open Access Journals (Sweden)

    Scholz Uwe

    2011-10-01

    Full Text Available Abstract Background Next generation sequencing of BACs is a viable option for deciphering the sequence of even large and highly repetitive genomes. In order to optimize this strategy, we examined the influence of read length on the quality of Roche/454 sequence assemblies, to what extent Illumina/Solexa mate pairs (MPs improve the assemblies by scaffolding and whether barcoding of BACs is dispensable. Results Sequencing four BACs with both FLX and Titanium technologies revealed similar sequencing accuracy, but showed that the longer Titanium reads produce considerably less misassemblies and gaps. The 454 assemblies of 96 barcoded BACs were improved by scaffolding 79% of the total contig length with MPs from a non-barcoded library. Assembly of the unmasked 454 sequences without separation by barcodes revealed chimeric contig formation to be a major problem, encompassing 47% of the total contig length. Masking the sequences reduced this fraction to 24%. Conclusion Optimal BAC pool sequencing should be based on the longest available reads, with barcoding essential for a comprehensive assessment of both repetitive and non-repetitive sequence information. When interest is restricted to non-repetitive regions and repeats are masked prior to assembly, barcoding is non-essential. In any case, the assemblies can be improved considerably by scaffolding with non-barcoded BAC pool MPs.

  17. Genomic analyses of tropical beef cattle fertility based on genotyping pools of Brahman cows with unknown pedigree.

    Science.gov (United States)

    Reverter, A; Porto-Neto, L R; Fortes, M R S; McCulloch, R; Lyons, R E; Moore, S; Nicol, D; Henshall, J; Lehnert, S A

    2016-10-01

    We introduce an innovative approach to lowering the overall cost of obtaining genomic EBV (GEBV) and encourage their use in commercial extensive herds of Brahman beef cattle. In our approach, the DNA genotyping of cow herds from 2 independent properties was performed using a high-density bovine SNP chip on DNA from pooled blood samples, grouped according to the result of a pregnancy test following their first and second joining opportunities. For the DNA pooling strategy, 15 to 28 blood samples from the same phenotype and contemporary group were allocated to pools. Across the 2 properties, a total of 183 pools were created representing 4,164 cows. In addition, blood samples from 309 bulls from the same properties were also taken. After genotyping and quality control, 74,584 remaining SNP were used for analyses. Pools and individual DNA samples were related by means of a "hybrid" genomic relationship matrix. The pooled genotyping analysis of 2 large and independent commercial populations of tropical beef cattle was able to recover significant and plausible associations between SNP and pregnancy test outcome. We discuss 24 SNP with significant association ( < 1.0 × 10) and mapped within 40 kb of an annotated gene. We have established a method to estimate the GEBV in young herd bulls for a trait that is currently unable to be predicted at all. In summary, our novel approach allowed us to conduct genomic analyses of fertility in 2 large commercial Brahman herds managed under extensive pastoral conditions.

  18. 48 CFR 28.304 - Risk-pooling arrangements.

    Science.gov (United States)

    2010-10-01

    ... CONTRACTING REQUIREMENTS BONDS AND INSURANCE Insurance 28.304 Risk-pooling arrangements. Agencies may establish risk-pooling arrangements. These arrangements are designed to use the services of the insurance industry for safety engineering and the handling of claims at minimum cost to the Government. The agency...

  19. Physical-chemical model for cellular uptake of fatty acids: prediction of intracellular pool sizes

    International Nuclear Information System (INIS)

    Cooper, R.; Noy, N.; Zakim, D.

    1987-01-01

    If the uptake of fatty acids by liver is a physical, not a biological, process, then the size and location of the intrahepatic pool of fatty acids can be predicted from uptake rates and thermodynamic data. The purpose of the experiments in this paper was to test the accuracy of this idea. Rat livers were perfused with [ 3 H] palmitate bound to [ 14 C] albumin, and the total amounts of palmitate removed from the perfusate were measured at 3-s intervals. The intrahepatic pools of palmitate calculated from these data were 13.8 and 23.0 nmol/g of liver at ratios of palmitate/albumin (mol/mol) (afferent side) of 2/1 and 4/1, respectively, in the steady state. The intrahepatic pools of palmitate calculated from the distributions of palmitate between membranes, H 2 O, albumin, and fatty acid binding protein and the measured first-order rate constants for acyl-CoA ligases in mitochondria and microsomes were 12.1 and 34.6 nmol/g for perfusate ratios of palmitate/albumin of 2/1 and 4/1, in the steady state. Intrahepatic pools of palmitate measured after establishment of a steady-state rate of uptake were 15.0 and 31.8 nmol/g for these ratios of palmitate/albumin of 2/1 and 4/1

  20. Indoor swimming pools. Humidity caused problems and suggested solutions

    Energy Technology Data Exchange (ETDEWEB)

    1989-01-01

    Reports have been received from across Canada on premature deterioration and other problems of indoor swimming pool buildings. This technical paper has been prepared to assist pool managers to solve these problems, which typically include leaking roofs, condensation on inside walls, peeling paint, efflorescence, rusting of metal elements, deterioration of concrete block structures, and high costs for pool heating. An effective insulation and vapor barrier system for a swimming pool roof is described, and the high relative humidity of the typical pool building is discussed as the primary cause of most problems. Proper sealing to cut down air infiltration is recommended, along with proper maintenance and painting. High energy costs are often due to low insulation values and to excessive ventilation used for decreasing the humidity. By using dehumidifiers capable of heat recovery, and by placing an insulating blanket on the pool after operating hours, it is shown that substantial cost savings are possible. 10 figs.

  1. Expanding the live kidney donor pool: ethical considerations regarding altruistic donors, paired and pooled programs.

    Science.gov (United States)

    Patel, Shaneel Rajendra; Chadha, Priyanka; Papalois, Vassilios

    2011-06-01

    In renal transplant, there is a well-known deficiency in organ supply relative to demand. Live donation provides superior results when compared with deceased donation including a better rate of graft success and fewer immunologic complications. This deficiency in organs leads to significant morbidity and mortality rates. Alternative avenues have been extensively explored that may expand the live donor pool. They include altruistic donation as well as paired and pooled exchange programs. Altruistic donation is a truly selfless act from a donor unknown to the recipient. Kidney paired donation involves 2 incompatible donor-recipient pairs swapping donors to produce compatibility. Pooled donation involves at least 2 pairs, and can take the form of domino chains in which altruistic input sets up a chain of transplants, in which each recipient's incompatible donor makes a donation for the next recipient. Despite application of these various methods, there lie extensive ethical issues surrounding them. Misconceptions frequently occur; for instance, the perceived benefit that donating an organ to a loved one is greater for a related donor than for an altruistic one. Additionally, it is frequently believed that immunologic incompatibility offers coerced donors liberation from surgery, and that overcoming these barriers by introducing exchange programs provides vulnerable donors less protection. This article explores these and other complex ethical issues surrounding the various methods of expanding the donor pool. The authors offer opinions that challenge the ethical issues and attempt to overcome those views that hinder progress in the field.

  2. LNG pool fire simulation for domino effect analysis

    International Nuclear Information System (INIS)

    Masum Jujuly, Muhammad; Rahman, Aziz; Ahmed, Salim; Khan, Faisal

    2015-01-01

    A three-dimensional computational fluid dynamics (CFD) simulation of liquefied natural gas (LNG) pool fire has been performed using ANSYS CFX-14. The CFD model solves the fundamental governing equations of fluid dynamics, namely, the continuity, momentum and energy equations. Several built-in sub-models are used to capture the characteristics of pool fire. The Reynolds-averaged Navier–Stokes (RANS) equation for turbulence and the eddy-dissipation model for non-premixed combustion are used. For thermal radiation, the Monte Carlo (MC) radiation model is used with the Magnussen soot model. The CFD results are compared with a set of experimental data for validation; the results are consistent with experimental data. CFD results show that the wind speed has significant contribution on the behavior of pool fire and its domino effects. The radiation contours are also obtained from CFD post processing, which can be applied for risk analysis. The outcome of this study will be helpful for better understanding of the domino effects of pool fire in complex geometrical settings of process industries. - Highlights: • Simulation of pool fire using computational fluid dynamics (CFD) model. • Integration of CFD based pool fire model with domino effect. • Application of the integrated CFD based domino effect analysis

  3. A method of measuring a molten metal liquid pool volume

    Science.gov (United States)

    Garcia, G.V.; Carlson, N.M., Donaldson, A.D.

    1990-12-12

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figs.

  4. Automated management of engineering infrastructure of pools of different purpose

    Directory of Open Access Journals (Sweden)

    Shirokov Lev Alekseevich

    2016-10-01

    Full Text Available Pools play an important role in people’s life. They answer people’s demand in rest and improve their health. At the same time pools are rather important for industrial use, for example in construction industry. In order to solve different construction problems it is essential to investigate the influence of microclimatic parameters on construction materials and structures. For this aim pools are in demand as special test sites for construction materials and structures in different environmental conditions including the case of a direct water impact. The efficient use of pools presupposes the necessity of constant hydroclimatic contro: air humidity and temperature, water temperature, chemical composition of water and air. Classification of pools of different purposes is presented in the article. The author considers the main problems of operation of pools as objects with complicated air-and-water environment. The questions of maintaining optimal microclimatic parameters in a pool are considered. The necessity of use of the control system of a microclimate, its efficiency, profitability and social effect of its implementation is described. A mathematical model of the thermal mode of a pool area is constructed. The process of indoor temperature regulation in the pool is considered.

  5. Crust formation and its effect on the molten pool coolability

    Energy Technology Data Exchange (ETDEWEB)

    Park, R.J.; Lee, S.J.; Sim, S.K. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-09-01

    Experimental and analytical studies of the crust formation and its effect on the molten pool coolability have been performed to examine the crust formation process as a function of boundary temperatures as well as to investigate heat transfer characteristics between molten pool and overlying water in order to evaluate coolability of the molten pool. The experimental test results have shown that the surface temperature of the bottom plate is a dominant parameter in the crust formation process of the molten pool. It is also found that the crust thickness of the case with direct coolant injection into the molten pool is greater than that of the case with a heat exchanger. Increasing mass flow rate of direct coolant injection to the molten pool does not affect the temperature of molten pool after the crust has been formed in the molten pool because the crust behaves as a thermal barrier. The Nusselt number between the molten pool and the coolant of the case with no crust formation is greater than that of the case with crust formation. The results of FLOW-3D analyses have shown that the temperature distribution contributes to the crust formation process due to Rayleigh-Benard natural convection flow.

  6. Backfitting swimming pool reactors

    International Nuclear Information System (INIS)

    Roebert, G.A.

    1978-01-01

    Calculations based on measurements in a critical assembly, and experiments to disclose fuel element surface temperatures in case of accidents like stopping of primary coolant flow during full power operation, have shown that the power of the swimming pool type research reactor FRG-2 (15 MW, operating since 1967) might be raised to 21 MW within the present rules of science and technology, without major alterations of the pool buildings and the cooling systems. A backfitting program is carried through to adjust the reactor control systems of FRG-2 and FRG-1 (5 MW, housed in the same reactor hall) to the present safety rules and recommendations, to ensure FRG-2 operation at 21 MW for the next decade. (author)

  7. Tax credits and purchasing pools: will this marriage work?

    Science.gov (United States)

    Trude, S; Ginsburg, P B

    2001-04-01

    Bipartisan interest is growing in Congress for using federal tax credits to help low-income families buy health insurance. Regardless of the approach taken, tax credit policies must address risk selection issues to ensure coverage for the chronically ill. Proposals that link tax credits to purchasing pools would avoid risk selection by grouping risks similar to the way large employers do. Voluntary purchasing pools have had only limited success, however. This Issue Brief discusses linking tax credits to purchasing pools. It uses information from the Center for Studying Health System Change's (HSC) site visits to 12 communities as well as other research to assess the role of purchasing pools nationwide and the key issues and implications of linking tax credits and pools.

  8. Design of inventory pools in spare part support operation systems

    Science.gov (United States)

    Mo, Daniel Y.; Tseng, Mitchell M.; Cheung, Raymond K.

    2014-06-01

    The objective of a spare part support operation is to fulfill the part request order with different service contracts in the agreed response time. With this objective to achieve different service targets for multiple service contracts and the considerations of inventory investment, it is not only important to determine the inventory policy but also to design the structure of inventory pools and the order fulfilment strategies. In this research, we focused on two types of inventory pools: multiple inventory pool (MIP) and consolidated inventory pool (CIP). The idea of MIP is to maintain separated inventory pools based on the types of service contract, while CIP solely maintains a single inventory pool regardless of service contract. Our research aims to design the inventory pool analytically and propose reserve strategies to manage the order fulfilment risks in CIP. Mathematical models and simulation experiments would be applied for analysis and evaluation.

  9. Flashing oscillation in pool water

    International Nuclear Information System (INIS)

    Takamasa, Tomoji; Kondo, Koichi; Hazuku, Tatsuya

    1996-01-01

    This paper presents an experimental study of high-pressure saturated water discharging into the pool water. The purpose of the experiment is to clarify the phenomena that occur in blow-down of high-pressure saturated water from the pressure vessel into the water-filled containment in the case of a wall-crack accident or a LOCA in an advanced reactor. The results revealed that a flashing oscillation (FO) occurs when high-pressure saturated water discharges into the pool water, under specified experimental settings. The range of the flashing oscillates between a point very close to and some distance from the vent hole. The pressures in the vent tube and pool water vary according to the flashing oscillation. The pressure oscillation and frequency of flashing position might be caused by the balancing action between the supply of saturated water, flashing at the control volume and its condensation on the steam-water interface. A linear analysis was conducted using a spherical flashing bubble model. The period of the flashing oscillation in the experiments can be explained by theoretical analysis

  10. Vitamin D Pooling Project

    Science.gov (United States)

    The Vitamin D Pooling Project of Rarer Cancers brought together investigators from 10 cohorts to conduct a large prospective epidemiologic study of the association between vitamin D status and seven rarer cancers.

  11. Stability and Scalability of the CMS Global Pool: Pushing HTCondor and GlideinWMS to New Limits

    Energy Technology Data Exchange (ETDEWEB)

    Balcas, J. [Caltech; Bockelman, B. [Nebraska U.; Hufnagel, D. [Fermilab; Hurtado Anampa, K. [Notre Dame U.; Aftab Khan, F. [NCP, Islamabad; Larson, K. [Fermilab; Letts, J. [UC, San Diego; Marra da Silva, J. [Sao Paulo, IFT; Mascheroni, M. [Fermilab; Mason, D. [Fermilab; Perez-Calero Yzquierdo, A. [Madrid, CIEMAT; Tiradani, A. [Fermilab

    2017-11-22

    The CMS Global Pool, based on HTCondor and glideinWMS, is the main computing resource provisioning system for all CMS workflows, including analysis, Monte Carlo production, and detector data reprocessing activities. The total resources at Tier-1 and Tier-2 grid sites pledged to CMS exceed 100,000 CPU cores, while another 50,000 to 100,000 CPU cores are available opportunistically, pushing the needs of the Global Pool to higher scales each year. These resources are becoming more diverse in their accessibility and configuration over time. Furthermore, the challenge of stably running at higher and higher scales while introducing new modes of operation such as multi-core pilots, as well as the chaotic nature of physics analysis workflows, places huge strains on the submission infrastructure. This paper details some of the most important challenges to scalability and stability that the CMS Global Pool has faced since the beginning of the LHC Run II and how they were overcome.

  12. Pooled versus separate measurements of tree-ring stable isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Dorado Linan, Isabel, E-mail: isabel@gfz-potsdam.de [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Gutierrez, Emilia, E-mail: emgutierrez@ub.edu [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); Helle, Gerhard, E-mail: ghelle@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Heinrich, Ingo, E-mail: heinrich@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Andreu-Hayles, Laia, E-mail: laiandreu@ub.edu [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); Tree-Ring Laboratory, Lamont-Doherty Earth Observatory of Columbia University, Palisades NY (United States); Planells, Octavi, E-mail: leocarpus@hotmail.com [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); Leuenberger, Markus, E-mail: leuenberger@climate.unibe.ch [Climate and Environmental Physics, Physics Institute, University of Bern, Sidlerstrasse 5, 3012 Bern (Switzerland); Oeschger Centre of Climate Change Research, University of Bern, Zaehringerstrasse 25, 3012 Bern (Switzerland); Buerger, Carmen, E-mail: buerger@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Schleser, Gerhard, E-mail: schleser@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany)

    2011-05-01

    {delta}{sup 13}C and {delta}{sup 18}O of tree rings contain time integrated information about the environmental conditions weighted by seasonal growth dynamics and are well established as sources of palaeoclimatic and ecophysiological data. Annually resolved isotope chronologies are frequently produced by pooling dated growth rings from several trees prior to the isotopic analyses. This procedure has the advantage of saving time and resources, but precludes from defining the isotopic error or statistical uncertainty related to the inter-tree variability. Up to now only a few studies have compared isotope series from pooled tree rings with isotopic measurements from individual trees. We tested whether or not the {delta}{sup 13}C and the {delta}{sup 18}O chronologies derived from pooled and from individual tree rings display significant differences at two locations from the Iberian Peninsula to assess advantages and constraints of both methodologies. The comparisons along the period 1900-2003 reveal a good agreement between pooled chronologies and the two mean master series which were created by averaging raw individual values (Mean) or by generating a mass calibrated mean (MassC). In most of the cases, pooled chronologies show high synchronicity with averaged individual samples at interannual scale but some differences also show up especially when comparing {delta}{sup 18}O decadal to multi-decadal variations. Moreover, differences in the first order autocorrelation among individuals may be obscured by pooling strategies. The lack of replication of pooled chronologies prevents detection of a bias due to a higher mass contribution of one sample but uncertainties associated with the analytical process itself, as sample inhomogeneity, seems to account for the observed differences. - Research Highlights: {yields} Pooled {delta}{sup 13}C and {delta}{sup 18}O chronologies are expected to be similar to the mean. {yields} Empirical pooled chronologies {delta}{sup 13}C and

  13. Pooled versus separate measurements of tree-ring stable isotopes

    International Nuclear Information System (INIS)

    Dorado Linan, Isabel; Gutierrez, Emilia; Helle, Gerhard; Heinrich, Ingo; Andreu-Hayles, Laia; Planells, Octavi; Leuenberger, Markus; Buerger, Carmen; Schleser, Gerhard

    2011-01-01

    δ 13 C and δ 18 O of tree rings contain time integrated information about the environmental conditions weighted by seasonal growth dynamics and are well established as sources of palaeoclimatic and ecophysiological data. Annually resolved isotope chronologies are frequently produced by pooling dated growth rings from several trees prior to the isotopic analyses. This procedure has the advantage of saving time and resources, but precludes from defining the isotopic error or statistical uncertainty related to the inter-tree variability. Up to now only a few studies have compared isotope series from pooled tree rings with isotopic measurements from individual trees. We tested whether or not the δ 13 C and the δ 18 O chronologies derived from pooled and from individual tree rings display significant differences at two locations from the Iberian Peninsula to assess advantages and constraints of both methodologies. The comparisons along the period 1900-2003 reveal a good agreement between pooled chronologies and the two mean master series which were created by averaging raw individual values (Mean) or by generating a mass calibrated mean (MassC). In most of the cases, pooled chronologies show high synchronicity with averaged individual samples at interannual scale but some differences also show up especially when comparing δ 18 O decadal to multi-decadal variations. Moreover, differences in the first order autocorrelation among individuals may be obscured by pooling strategies. The lack of replication of pooled chronologies prevents detection of a bias due to a higher mass contribution of one sample but uncertainties associated with the analytical process itself, as sample inhomogeneity, seems to account for the observed differences. - Research Highlights: → Pooled δ 13 C and δ 18 O chronologies are expected to be similar to the mean. → Empirical pooled chronologies δ 13 C and δ 18 O and the mean show a high synchronicity. → Pooled chronologies differ

  14. Suncatcher and cool pool. Project report

    Energy Technology Data Exchange (ETDEWEB)

    Hammond, J.

    1981-03-01

    The Suncatcher is a simple, conical solar concentrating device that captures light entering clerestory windows and directs it onto thermal storage elements at the back of a south facing living space. The cone shape and inclination are designed to capture low angle winter sunlight and to reflect away higher angle summer sunlight. It is found that winter radiation through a Suncatcher window is 40 to 50% higher than through an ordinary window, and that the average solar fraction is 59%. Water-filled steal culvert pipes used for thermal storage are found to undergo less stratification, and thus to be more effective, when located where sunlight strikes the bottom rather than the top. Five Suncatcher buildings are described. Designs are considered for 32/sup 0/, 40/sup 0/ and 48/sup 0/ north latitude, and as the latitude increases, the inclination angle of the cone should be lowered. The Cool Pool is an evaporating, shaded roof pond which thermosiphons cool water into water-filled columns within a building. Preliminary experiments indicate that the best shade design has unimpeded north sky view, good ventilation, complete summer shading, a low architectural profile, and low cost attic vent lowers work. Another series of experiments established the satisfactory performance of the Cool Pool on a test building using four water-filled cylinders, two cylinders, and two cylinders connected to the Cool Pool through a heat exchanger. Although an unshaded pool cools better at night than a shaded one, daytime heat gain far offsets this advantage. A vinyl waterbag heat exchanger was developed for use with the Cool Pool. (LEW)

  15. Limnological Monitoring on the Upper Mississippi River System, 1993-1996: Long Term Resource Monitoring Program Pool 26 Field Station

    National Research Council Canada - National Science Library

    Soballe, David

    2002-01-01

    .... The 1993-1996 water quality data for the Pool 26 area show long-term declines in the concentrations of total nitrogen, nitrate-nitrite nitrogen, and soluble reactive phosphorus after the large flood in 1993...

  16. Flow dynamics of volume-heated boiling pools

    International Nuclear Information System (INIS)

    Ginsberg, T.; Jones, O.C.; Chen, J.C.

    1979-01-01

    Safety analyses of fast breeder reactors require understanding of the two-phase fluid dynamic and heat transfer characteristics of volume-heated boiling pool systems. Design of direct contact three-phase boilers, of practical interest in the chemical industries also requires understanding of the fundamental two-phase flow and heat transfer behavior of volume boiling systems. Several experiments have been recently reported relevant to the boundary heat-loss mechanisms of boiling pool systems. Considerably less is known about the two-phase fluid dynamic behavior of such systems. This paper describes an experimental investigation of the steady-state flow dynamics of volume-heated boiling pool systems

  17. Laser surveillance systems for fuel storage pools

    International Nuclear Information System (INIS)

    Boeck, H.

    1985-06-01

    A Laser Surveillance System (LASSY) as a new safeguards device has been developed under the IAEA research contract No. 3458/RB at the Atominstitut Wien using earlier results by S. Fiarman. This system is designed to act as a sheet of light covering spent fuel assemblies in spent fuel storage pools. When movement of assemblies takes place, LASSY detects and locates the position of the movement in the pool and when interrogated, presents a list of pool positions and times of movement to the safeguards inspector. A complete prototype system was developed and built. Full scale tests showed the principal working capabilities of a LASSY underwater

  18. Thermophysical modeling of volatile fission product release from a debris pool

    International Nuclear Information System (INIS)

    Yun, J. I.; Suh, K. Y.; Kang, C. S.

    1999-01-01

    A model is described for fission product release from the debris pool in the lower plenum of the reactor pressure vessel. In the pool, turbulent natural convection flow is formed due to homogeneous internal heat generation. Using the best-known correlations, heat transfer at the curved bottom and the top of the pool may be calculated. Volatile fission product gases in the pool nucleate and diffuse to bubbles. Both the homogeneous nucleation and heterogeneous nucleation are considered. The bubble nucleation, growth, coalescence and loss due to rise is modeled pursuant to bubble dynamics. If the pressure and temperature of the pool are very high, homogeneous nucleation that accounts for effect of decrease in the pool pressure can occur. The effect of the bubble-to-pool interfacial tension and the pool pressure on the nucleation rate is investigated in this work

  19. Meat intake and cause-specific mortality: a pooled analysis of Asian prospective cohort studies123

    Science.gov (United States)

    Lee, Jung Eun; McLerran, Dale F; Rolland, Betsy; Chen, Yu; Grant, Eric J; Vedanthan, Rajesh; Inoue, Manami; Tsugane, Shoichiro; Gao, Yu-Tang; Tsuji, Ichiro; Kakizaki, Masako; Ahsan, Habibul; Ahn, Yoon-Ok; Pan, Wen-Harn; Ozasa, Kotaro; Yoo, Keun-Young; Sasazuki, Shizuka; Yang, Gong; Watanabe, Takashi; Sugawara, Yumi; Parvez, Faruque; Kim, Dong-Hyun; Chuang, Shao-Yuan; Ohishi, Waka; Park, Sue K; Feng, Ziding; Thornquist, Mark; Boffetta, Paolo; Zheng, Wei; Kang, Daehee; Potter, John; Sinha, Rashmi

    2013-01-01

    Background: Total or red meat intake has been shown to be associated with a higher risk of mortality in Western populations, but little is known of the risks in Asian populations. Objective: We examined temporal trends in meat consumption and associations between meat intake and all-cause and cause-specific mortality in Asia. Design: We used ecological data from the United Nations to compare country-specific meat consumption. Separately, 8 Asian prospective cohort studies in Bangladesh, China, Japan, Korea, and Taiwan consisting of 112,310 men and 184,411 women were followed for 6.6 to 15.6 y with 24,283 all-cause, 9558 cancer, and 6373 cardiovascular disease (CVD) deaths. We estimated the study-specific HRs and 95% CIs by using a Cox regression model and pooled them by using a random-effects model. Results: Red meat consumption was substantially lower in the Asian countries than in the United States. Fish and seafood consumption was higher in Japan and Korea than in the United States. Our pooled analysis found no association between intake of total meat (red meat, poultry, and fish/seafood) and risks of all-cause, CVD, or cancer mortality among men and women; HRs (95% CIs) for all-cause mortality from a comparison of the highest with the lowest quartile were 1.02 (0.91, 1.15) in men and 0.93 (0.86, 1.01) in women. Conclusions: Ecological data indicate an increase in meat intake in Asian countries; however, our pooled analysis did not provide evidence of a higher risk of mortality for total meat intake and provided evidence of an inverse association with red meat, poultry, and fish/seafood. Red meat intake was inversely associated with CVD mortality in men and with cancer mortality in women in Asian countries. PMID:23902788

  20. Review of steam jet condensation in a water pool

    International Nuclear Information System (INIS)

    Kim, Y. S.; Song, C. H.; Park, C. K.; Kang, H. S.; Jeon, H. G.; Yoon, Y. J.

    2002-01-01

    In the advanced nuclear power plants including APR1400, the SDVS is adopted to increase the plant safety using the concept of feed-and-bleed operation. In the case of the TLOFW, the POSRV located at the top of the pressurizer is expected to open due to the pressurization of the reactor coolant system and discharges steam and/or water mixture into the water pool, where the mixture is condensed. During the condensation of the mixture, thermal-hydraulic loads such as pressure and temperature variations are induced to the pool structure. For the pool structure design, such thermal-hydraulic aspects should be considered. Understanding the phenomena of the submerged steam jet condensation in a water pool is helpful for system designers to design proper pool structure, sparger, and supports etc. This paper reviews and evaluates the steam jet condensation in a water pool on the physical phenomena of the steam condensation including condensation regime map, heat transfer coefficient, steam plume, steam jet condensation load, and steam jet induced flow

  1. Code Development of Radioactive Aerosol Scrubbing in Pool-Injection Zone

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Hyun Joung; Ha, Kwang Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Jang, Dong Soon [Chungnam National University, Daejeon (Korea, Republic of)

    2015-10-15

    The pool scrubbing models were reviewed and an aerosol scrubbing code has been prepared to calculate decontamination factor through the injection zone. The developed code has been verified using the experimental results and evaluated parametrically on the input variables. In injection zone, the initial steam condensation was most effective mechanism for the aerosol removal, and the steam fraction and pool temperature were highly affected on the decontamination factor by initial steam condensation. The aerosol scrubbing code will be updated to evaluate the decontamination factor at rise zone and finally whole pool scrubber phenomena. If a severe accident occurs in a nuclear power plant (NPP), the aerosol and gaseous fission products might be produced in the reactor vessel, and then released to the environment after the containment failure. FCVS (Filtered Containment Venting System) is one of the severe accident mitigation systems for retaining the containment integrity by discharging the high-temperature and high-pressure fission products to the environment after passing through the filtration system. In general, the FCVS is categorized into two types, wet and dry types. The scrubbing pool could play an important role in the wet type FCVS because a large amount of aerosol is captured in the water pool. The pool scrubbing phenomena have been modelled and embedded in several computer codes, such as SPARC (Suppression Pool Aerosol Removal Code), BUSCA (BUbble Scrubbing Algorithm) and SUPRA (Suppression Pool Retention Analysis). These codes aim at simulating the pool scrubbing process and estimating the decontamination factors (DFs) of the radioactive aerosol and iodine gas in the water pool, which is defined as the ratio of initial mass of the specific radioactive material to final massy after passing through the water pool. The pool scrubbing models were reviewed and an aerosol scrubbing code has been prepared to calculate decontamination factor through the injection

  2. Competition and power pooling in the electricity industry

    International Nuclear Information System (INIS)

    Jasinski, P.; Yarrow, G.; Fusaro, P.

    1995-01-01

    Two contributions to the debate on power pooling and competition in the electricity supply industry are presented. In the first, the situation in England and Wales where power pooling was introduced shortly before privatization is analysed. Pooling has existed for many years in the USA but as an inter-generator arrangement designed to optimize production and costs. The British system sought in addition to establish a spot market in which bulk buyers as well as bulk suppliers could participate. There are however obvious weaknesses in the pool as a competitive market and it is argued that a combination of pooling arrangements and longer-term bilateral supply contracts are more likely to offer the prospect of workably competitive and efficient outcomes. The second contribution discusses how competitive markets will evolve in the USA under the new regime of less onerous regulation heralded by the Energy Policy Act if 1992 and the emergence of electricity trading markets which followed. In particular, the proposal by the California Public Utility commission favouring a mandatory Poolco is examined. Poolco would operate the transmission grid and dispatch generating plants while the utilities would retain ownership of transmission facilities and be required to supply the pool. This is seen as representing only partial deregulation and not to be consistent with moves to further competition and encourage free markets. (U.K.)

  3. Pooling strategies for St Petersburg gamblers

    OpenAIRE

    Csörgö, Sandor; Simons, Gordon

    2006-01-01

    Peter offers to play exactly one St Petersburg game with each of [math] players, Paul [math] , [math] , Paul [math] , whose conceivable pooling strategies are described by all possible probability distributions [math] . Comparing infinite expectations, we characterize among all [math] those admissible strategies for which the pooled winnings, each distributed as [math] , yield a finite added value for each and every one of Paul [math] , [math] , Paul [math] in comparison with their individual...

  4. Swimming pool special; Zwembadspecial

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-05-15

    This issue includes a few articles and messages on the use of heat pump systems in swimming pools. [Dutch] Dit nummer bevat onder meer een paar artikelen over het gebruik van warmtepompsystemen in zwembaden.

  5. PRELIMINARY STUDY OF FISH CULTURE IN ABANDONED SAND MINING POOL

    Directory of Open Access Journals (Sweden)

    Bambang Gunadi

    2006-12-01

    Full Text Available One of main problems in freshwater aquaculture development in Indonesia, especially in Java, is unavailability of developing zone. It is important to find an underutilized area that meets for industrial scale freshwater aquaculture, i.e. sufficient water supply, wide area, and located in one area or zone. The abandoned mining (sand, tin, etc. pools distributed along the country might be the potential area for freshwater aquaculture business. For example, there are at least 13 water pools with total surface area of 250 ha at 15 km side of Citarum River in Karawang District (West Java Province. This study was conducted to obtain preliminary data about the prospect and potency of fish culture (tilapia, clariid catfish, and ‘patin’ catfish in abandoned sand-mining pools in Karawang District. Mini floating net cages of 1 x 1 x 1.5 m3 size were used for culturing fish, i.e. patin catfish (Pangasianodon hypophthalmus, nile tilapia (Oreochromis niloticus, and clariid catfish (Clarias gariepinus, separately. Patin catfish were stocked at a size of 2 g with a density of 300 fish per cage, tilapia were stocked at a size of 6 g with a density of 400 fish per cage, while  the clariid catfish were stocked at a size of 1.4 g with a density of 980 fish per cage. A floating commercial feed (30%—32% protein, 3%—5% fat was used at a daily rate of 9% biomass weight at the beginning and reduced gradually to 3% at the final culture period. Observed data showed that patin catfish grew from the initial size of 2.08 g to the final size 299.59 g in 5 months, nile tilapia grew from individual initial size of 5.92 g to the final size of 247.12 g in 14 weeks, and clariid catfish grew from initial size of 1.39 g to the final size of 73.10 g in 8 weeks. These three species were technically prospective for aquaculture development in the abandoned sand-mining pools.

  6. Rivaroxaban for the prevention of venous thromboembolism after hip or knee arthroplasty. Pooled analysis of four studies

    DEFF Research Database (Denmark)

    Turpie, A G G; Lassen, M R; Eriksson, Birgit

    2011-01-01

    Four phase III studies compared oral rivaroxaban with subcutaneous enoxaparin for the prevention of venous thromboembolism (VTE) after total hip or knee arthroplasty (THA or TKA). A pooled analysis of these studies compared the effect of rivaroxaban with enoxaparin on symptomatic VTE plus all-cau...

  7. Primary Total Knee Replacement: Is Suction a Portal of Infection?

    Science.gov (United States)

    Budnar, Vijaya M; Amirfeyz, Rouin; Ng, Michael; Bannister, Gordon C; Blom, Ashley W

    2009-01-01

    INTRODUCTION Pulsed lavage during a total knee replacement usually leaves a pool of fluid on the surgical drapes. It is common practice to suck away this fluid using the same suction device used intra-operatively. This could be a cause of direct wound contamination. We hypothesised that bacteria contaminate fluid that collects around the foot in total knee replacement surgery and that suction equipment could be a portal of contamination. We also hypothesised that bacterial count in the fluid is lower if chlorhexidine, rather than saline, is used in the pulsed lavage. PATIENTS AND METHODS Forty patients undergoing primary total knee replacement were divided into two groups. The first group had pulsed lavage with normal saline and the second with 0.05% chlorhexidine. RESULTS At the end of the operation, 20 ml of fluid, pooled on the surgical drapes was aspirated and cultured for bacterial growth. None of the fluid samples showed bacterial growth. CONCLUSIONS Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine. PMID:19335972

  8. The warm pool in the Indian Ocean

    Digital Repository Service at National Institute of Oceanography (India)

    Vinayachandran, P.N.; Shetye, S.R.

    is larger and warmer, a peculiarity of the pool in the Indian Ocean is its seasonal variation. The surface area of the pool changes from 24 x 106 km2 in April to 8 x 106 km2 in September due to interaction with the southwest monsoon. The annual cycles of sea...

  9. Steam blowdown experiments with the condensation pool test rig

    International Nuclear Information System (INIS)

    Purhonen, H.; Puustinen, M.; Laine, J.; Raesaenen, A.; Kyrki-Rajamaeki, R.; Vihavainen, J.

    2005-01-01

    During a possible loss-of-coolant accident (Local) a large amount of non-condensable (nitrogen) and condensable (steam) gas is blown from the upper drywell of the containment to the condensation pool through the blowdown pipes at the boiling water reactors (BWRs). The wet well pool serves as the major heat sink for condensation of steam. The blowdown causes both dynamic and structural loads to the condensation pool. There might also be a risk that the gas discharging to the pool could push its way to the emergency core cooling systems (ECCS) and undermine their performance. (author)

  10. Simulation of pool scrubbing experiments using BUSCA

    International Nuclear Information System (INIS)

    Dehbi, A.; Guentay, S.

    1994-01-01

    BUSCA-PSI is a computer code which predicts the aerosol scrubbing taking place when gas bubbles containing fission products rise through stagnant pools of water after a postulated severe accident. A Lagrangian formulation is adopted to follow the path of a bubble as it rises toward the surface of the pool. The BUSCA model includes most aerosol removal mechanisms which are thought to be significant, namely: Jet Impaction at tile orifice, Convection/Diffusiophoresis during steam condensation, Thermophoresis, Sedimentation, Centrifugal Impaction during bubble rise, and Brownian Diffusion. The hydraulic modelling offers a variety of options for the initial globule volume, the stable bubble size, tile bubble rise velocity, and the bubble shape. The heat and mass transfer part of tile model uses correlations found in the relevant literature. BUSCA simulations were performed to determine the decontamination factor (DF) dependence on key aerosol and thermal hydraulic parameters. The decontamination factor increases with height, pool temperature subcooling, and steam content. The decontamination factor exhibits a parabolic dependence on the particle radius. At low particle sizes, the DF is high due to Brownian Diffusion which is the dominant removal mechanism. The DF hits a minimum and then increases with particle size as Centrifugal Impaction and Sedimentation become important. In separate calculations, BUSCA was used to the simulate the aerosol scrubbing experiments performed by EPRI. For cold pool tests, the predicted scrubbing efficiencies were in a good, conservative agreement with the data for both Tin and CsI, and the discrepancies were within the reported measurement errors. For hot pool tests, the code systematically underpredicted the scrubbing DF's; this is potentially due to condensation in the gas space above the pool, a situation not currently modelled by BUSCA. The code was also tested against data produced by the Tepco-Toshiba-Hitachi experiments. The

  11. Study on water evaporation rate from indoor swimming pools

    Directory of Open Access Journals (Sweden)

    Rzeźnik Ilona

    2017-01-01

    Full Text Available The air relative humidity in closed spaces of indoor swimming pools influences significantly on users thermal comfort and the stability of the building structure, so its preservation on suitable level is very important. For this purpose, buildings are equipped with HVAC systems which provide adequate level of humidity. The selection of devices and their technical parameters is made using the mathematical models of water evaporation rate in the unoccupied and occupied indoor swimming pool. In the literature, there are many papers describing this phenomena but the results differ from each other. The aim of the study was the experimental verification of published models of evaporation rate in the pool. The tests carried out on a laboratory scale, using model of indoor swimming pool, measuring 99cm/68cm/22cm. The model was equipped with water spray installation with six nozzles to simulate conditions during the use of the swimming pool. The measurements were made for conditions of sports pools (water temperature 24°C and recreational swimming pool (water temperature 34°C. According to the recommendations the air temperature was about 2°C higher than water temperature, and the relative humidity ranged from 40% to 55%. Models Shah and Biasin & Krumm were characterized by the best fit to the results of measurements on a laboratory scale.

  12. Peatland Open-water Pool Biogeochemistry: The Influence of Hydrology and Vegetation

    Science.gov (United States)

    Arsenault, J.; Talbot, J.; Moore, T. R.

    2017-12-01

    Peatland open-water pools are net sources of carbon to the atmosphere. However, their interaction with the surrounding peat remains poorly known. In a previous study, we showed that shallow pools are richer in nutrients than deep pools. While depth was the main driver of biogeochemistry variations across time and space, analyses also showed that pool's adjacent vegetation may have an influence on water chemistry. Our goal is to understand the relationship between the biogeochemistry of open-water pools and their surroundings in a subboreal ombrotrophic peatland of southern Quebec (Canada). To assess the influence of vegetation on pool water chemistry, we compare two areas covered with different types of vegetation: a forested zone dominated by spruce trees and an open area mostly covered by Sphagnum spp. To evaluate the direction of water (in or out of the pools), we installed capacitance water level probes in transects linking pools in the two zones. Wells were also installed next to each probe to collect peat pore water samples. Samples were taken every month during summer 2017 and analyzed for dissolved organic carbon, nitrogen and phosphorus, pH and specific UV absorbance. Preliminary results show differences in peat water chemistry depending on the dominant vegetation. In both zones, water levels fluctuations are disconnected between peat and the pools, suggesting poor horizontal water movement. Pool water chemistry may be mostly influenced by the immediate surrounding vegetation than by the local vegetation pattern. Climate and land-use change may affect the vegetation structure of peatlands, thus affecting pool biogeochemistry. Considering the impact of pools on the overall peatland capacity to accumulate carbon, our results show that more focus must be placed on pools to better understand peatland stability over time.

  13. The atmospheric wet pool: definition and comparison with the oceanic warm pool

    Institute of Scientific and Technical Information of China (English)

    ZHANG Caiyun; CHEN Ge

    2008-01-01

    The oceanic warm pool (OWP) defined by sea surface temperature (SST) is known as the "heat reservoir" in the ocean. The warmest portion in the ocean mirrors the fact that the wettest region with the largest accumulation of water vapor (WV) in the atmosphere, termed atmospheric wet pool (AWP), should be identified because of the well-known Clausius-Clapeyron relationship between SST and WV. In this study, we used 14-year simultaneous observations of WV and SST from January 1988 to December 2001 to define the AWP and investigate its coupling and co-variations with the OWP. The joint examination of the area variations, centroid locations, and zonal migrations of the AWP and OWP lead to a number of interesting findings. The results hopefully can contribute to our understanding of the air-sea interaction in general and characterization of El Nifio/La Nina events in particular.

  14. Sampling and Pooling Methods for Capturing Herd Level Antibiotic Resistance in Swine Feces using qPCR and CFU Approaches

    DEFF Research Database (Denmark)

    Schmidt, Gunilla Veslemøy; Mellerup, Anders; Christiansen, Lasse Engbo

    2015-01-01

    The aim of this article was to define the sampling level and method combination that captures antibiotic resistance at pig herd level utilizing qPCR antibiotic resistance gene quantification and culture-based quantification of antibiotic resistant coliform indicator bacteria. Fourteen qPCR assays...... for commonly detected antibiotic resistance genes were developed, and used to quantify antibiotic resistance genes in total DNA from swine fecal samples that were obtained using different sampling and pooling methods. In parallel, the number of antibiotic resistant coliform indicator bacteria was determined...... when comparing individual sampling and pooling methods. qPCR on pooled samples was found to be a good representative for the general resistance level in a pig herd compared to the coliform CFU counts. It had significantly reduced relative standard deviations compared to coliform CFU counts in the same...

  15. A Pooled Analysis of 15 Prospective Cohort Studies on the Association between Fruit, Vegetable, and Mature Bean Consumption and Risk of Prostate Cancer.

    Science.gov (United States)

    Petimar, Joshua; Wilson, Kathryn M; Wu, Kana; Wang, Molin; Albanes, Demetrius; van den Brandt, Piet A; Cook, Michael B; Giles, Graham G; Giovannucci, Edward L; Goodman, Gary E; Goodman, Phyllis J; Håkansson, Niclas; Helzlsouer, Kathy; Key, Timothy J; Kolonel, Laurence N; Liao, Linda M; Männistö, Satu; McCullough, Marjorie L; Milne, Roger L; Neuhouser, Marian L; Park, Yikyung; Platz, Elizabeth A; Riboli, Elio; Sawada, Norie; Schenk, Jeannette M; Tsugane, Shoichiro; Verhage, Bas; Wang, Ying; Wilkens, Lynne R; Wolk, Alicja; Ziegler, Regina G; Smith-Warner, Stephanie A

    2017-08-01

    Background: Relationships between fruit, vegetable, and mature bean consumption and prostate cancer risk are unclear. Methods: We examined associations between fruit and vegetable groups, specific fruits and vegetables, and mature bean consumption and prostate cancer risk overall, by stage and grade, and for prostate cancer mortality in a pooled analysis of 15 prospective cohorts, including 52,680 total cases and 3,205 prostate cancer-related deaths among 842,149 men. Diet was measured by a food frequency questionnaire or similar instrument at baseline. We calculated study-specific relative risks using Cox proportional hazards regression, and then pooled these estimates using a random effects model. Results: We did not observe any statistically significant associations for advanced prostate cancer or prostate cancer mortality with any food group (including total fruits and vegetables, total fruits, total vegetables, fruit and vegetable juice, cruciferous vegetables, and tomato products), nor specific fruit and vegetables. In addition, we observed few statistically significant results for other prostate cancer outcomes. Pooled multivariable relative risks comparing the highest versus lowest quantiles across all fruit and vegetable exposures and prostate cancer outcomes ranged from 0.89 to 1.09. There was no evidence of effect modification for any association by age or body mass index. Conclusions: Results from this large, international, pooled analysis do not support a strong role of collective groupings of fruits, vegetables, or mature beans in prostate cancer. Impact: Further investigation of other dietary exposures, especially indicators of bioavailable nutrient intake or specific phytochemicals, should be considered for prostate cancer risk. Cancer Epidemiol Biomarkers Prev; 26(8); 1276-87. ©2017 AACR . ©2017 American Association for Cancer Research.

  16. Loss of spent fuel pool cooling PRA: Model and results

    International Nuclear Information System (INIS)

    Siu, N.; Khericha, S.; Conroy, S.; Beck, S.; Blackman, H.

    1996-09-01

    This letter report documents models for quantifying the likelihood of loss of spent fuel pool cooling; models for identifying post-boiling scenarios that lead to core damage; qualitative and quantitative results generated for a selected plant that account for plant design and operational practices; a comparison of these results and those generated from earlier studies; and a review of available data on spent fuel pool accidents. The results of this study show that for a representative two-unit boiling water reactor, the annual probability of spent fuel pool boiling is 5 x 10 -5 and the annual probability of flooding associated with loss of spent fuel pool cooling scenarios is 1 x 10 -3 . Qualitative arguments are provided to show that the likelihood of core damage due to spent fuel pool boiling accidents is low for most US commercial nuclear power plants. It is also shown that, depending on the design characteristics of a given plant, the likelihood of either: (a) core damage due to spent fuel pool-associated flooding, or (b) spent fuel damage due to pool dryout, may not be negligible

  17. The Influence of RSG-GAS Primary Pump Operation Concerning the Rise Water Level of Reactor Pool in 15 MW Reactor Power

    International Nuclear Information System (INIS)

    Djunaidi

    2004-01-01

    The expansion of air volume in the delay chamber shows in rise water level of reactor pool during the operation. The rises of water level in the reactor pool is not quite from the expansion of air volume in the delay chamber, but some influence the primary pump operation. The purpose evaluated of influence primary pump is to know the influence primary pump power concerning the rise water level during the reactor operation. From the data collection during 15 MW power operation in the last core 42 the influence of primary pump operation concerning the rise water level in the reactor pool is 34.48 % from the total increased after operation during 12 days. (author)

  18. Infections Unlikely to be Spread Through Swimming Pools

    Science.gov (United States)

    ... Water Home Infections Unlikely to be Spread Through Swimming Pools Language: English (US) Español (Spanish) Recommend on ... included below. Infections Unlikely to be Spread by Swimming Pools Head Lice Head lice are unlikely to ...

  19. Secondary formation of disinfection by-products by UV treatment of swimming pool water

    Energy Technology Data Exchange (ETDEWEB)

    Spiliotopoulou, Aikaterini [Water ApS, Farum Gydevej 64, 3520 Farum (Denmark); Department of Environmental Engineering, Technical University of Denmark, Miljøvej, Building 113, 2800 Kongens Lyngby (Denmark); Hansen, Kamilla M.S., E-mail: kmsh@env.dtu.dk [Department of Environmental Engineering, Technical University of Denmark, Miljøvej, Building 113, 2800 Kongens Lyngby (Denmark); Andersen, Henrik R. [Department of Environmental Engineering, Technical University of Denmark, Miljøvej, Building 113, 2800 Kongens Lyngby (Denmark)

    2015-07-01

    Formation of disinfection by-products (DBPs) during experimental UV treatment of pool water has previously been reported with little concurrence between laboratory studies, field studies and research groups. In the current study, changes in concentration of seven out of eleven investigated volatile DBPs were observed in experiments using medium pressure UV treatment, with and without chlorine and after post-UV chlorination. Results showed that post-UV chlorine consumption increased, dose-dependently, with UV treatment dose. A clear absence of trihalomethane formation by UV and UV with chlorine was observed, while small yet statistically significant increases in dichloroacetonitrile and dichloropropanone concentrations were detected. Results indicate that post-UV chlorination clearly induced secondary formation of several DBPs. However, the formation of total trihalomethanes was no greater than what could be replicated by performing the DBP formation assay with higher chlorine concentrations to simulate extended chlorination. Post-UV chlorination of water from a swimming pool that continuously uses UV treatment to control combined chlorine could not induce secondary formation for most DBPs. Concurrence for induction of trihalomethanes was identified between post-UV chlorination treatments and simulated extended chlorination time treatment. Trihalomethanes could not be induced by UV treatment of water from a continuously UV treated pool. This indicates that literature reports of experimentally induced trihalomethane formation by UV may be a result of kinetic increase in formation by UV. However, this does not imply that higher trihalomethane concentrations would occur in pools that apply continuous UV treatment. The bromine fraction of halogens in formed trihalomethanes increased with UV dose. This indicates that UV removes bromine atoms from larger molecules that participate in trihalomethane production during post-UV chlorination. Additionally, no significant

  20. Secondary formation of disinfection by-products by UV treatment of swimming pool water

    International Nuclear Information System (INIS)

    Spiliotopoulou, Aikaterini; Hansen, Kamilla M.S.; Andersen, Henrik R.

    2015-01-01

    Formation of disinfection by-products (DBPs) during experimental UV treatment of pool water has previously been reported with little concurrence between laboratory studies, field studies and research groups. In the current study, changes in concentration of seven out of eleven investigated volatile DBPs were observed in experiments using medium pressure UV treatment, with and without chlorine and after post-UV chlorination. Results showed that post-UV chlorine consumption increased, dose-dependently, with UV treatment dose. A clear absence of trihalomethane formation by UV and UV with chlorine was observed, while small yet statistically significant increases in dichloroacetonitrile and dichloropropanone concentrations were detected. Results indicate that post-UV chlorination clearly induced secondary formation of several DBPs. However, the formation of total trihalomethanes was no greater than what could be replicated by performing the DBP formation assay with higher chlorine concentrations to simulate extended chlorination. Post-UV chlorination of water from a swimming pool that continuously uses UV treatment to control combined chlorine could not induce secondary formation for most DBPs. Concurrence for induction of trihalomethanes was identified between post-UV chlorination treatments and simulated extended chlorination time treatment. Trihalomethanes could not be induced by UV treatment of water from a continuously UV treated pool. This indicates that literature reports of experimentally induced trihalomethane formation by UV may be a result of kinetic increase in formation by UV. However, this does not imply that higher trihalomethane concentrations would occur in pools that apply continuous UV treatment. The bromine fraction of halogens in formed trihalomethanes increased with UV dose. This indicates that UV removes bromine atoms from larger molecules that participate in trihalomethane production during post-UV chlorination. Additionally, no significant

  1. Pressure supression pool thermal mixing

    International Nuclear Information System (INIS)

    Cook, D.H.

    1984-10-01

    A model is developed and verified to describe the thermal mixing that occurs in the pressure suppression pool (PSP) of a commercial BWR. The model is designed specifically for a Mark-I containment and is intended for use in severe accident sequence analyses. The model developed in this work produces space and time dependent temperature results throughout the PSP and is useful for evaluating the bulk PSP thermal mixing, the condensation effectiveness of the PSP, and the long-term containment integrity. The model is designed to accommodate single or multiple discharging T-quenchers, a PSP circumferential circulation induced by the residual heat removal system discharge, and the thermal stratification of the pool that occurs immediately after the relief valves close. The PSP thermal mixing is verified by comparing the model-predicted temperatures to experimental temperatures that were measured in an operating BWR suppression pool. The model is then used to investigate several PSP thermal mixing problems that include the time to saturate at full relief valve flow, the temperature response to a typical stuck open relief valve scenario, and the effect of operator rotation of the relief valve discharge point

  2. Pressure suppression pool thermal mixing

    International Nuclear Information System (INIS)

    Cook, D.H.

    1984-01-01

    A model is developed and verified to describe the thermal mixing that occurs in the pressure suppression pool (PSP) of a commercial BWR. The model is designed specifically for a Mark-I containment and is intended for use in severe accident sequence analyses. The model produces space and time dependent temperature results throughout the PSP and is useful for evaluating the bulk PSP thermal mixing, the condensation effectiveness of the PSP, and the long-term containment integrity. The model is designed to accommodate single or multiple discharging T-quenchers, a PSP circumferential circulation induced by the residual heat removal system discharge, and the thermal stratification of the pool that occurs immediately after the relief valves close. The PSP thermal mixing model is verified by comparing the model predicted temperatures to experimental temperatures that were measured in an operating BWR suppression pool. The model is then used to investigate several PSP thermal mixing problems that include the time to saturate at full relief valve flow, the temperature response to a typical stuck open relief valve scenario, and the effect of operator rotation of the relief valve discharge point

  3. Finding determinants of audit delay by pooled OLS regression analysis

    Directory of Open Access Journals (Sweden)

    Tina Vuko

    2014-03-01

    Full Text Available The aim of this paper is to investigate determinants of audit delay. Audit delay is measured as the length of time (i.e. the number of calendar days from the fiscal year-end to the audit report date. It is important to understand factors that influence audit delay since it directly affects the timeliness of financial reporting. The research is conducted on a sample of Croatian listed companies, covering the period of four years (from 2008 to 2011. We use pooled OLS regression analysis, modelling audit delay as a function of the following explanatory variables: audit firm type, audit opinion, profitability, leverage, inventory and receivables to total assets, absolute value of total accruals, company size and audit committee existence. Our results indicate that audit committee existence, profitability and leverage are statistically significant determinants of audit delay in Croatia.

  4. Test Area North Pool Stabilization Project: Environmental assessment

    International Nuclear Information System (INIS)

    1996-05-01

    The Test Area North (TAN) Pool is located within the fenced TAN facility boundaries on the Idaho National Engineering Laboratory (INEL). The TAN pool stores 344 canisters of core debris from the March, 1979, Three Mile Island (TMI) Unit 2 reactor accident; fuel assemblies from Loss-of-Fluid Tests (LOFT); and Government-owned commercial fuel rods and assemblies. The LOFT and government owned commercial fuel rods and assemblies are hereafter referred to collectively as open-quotes commercial fuelsclose quotes except where distinction between the two is important to the analysis. DOE proposes to remove the canisters of TMI core debris and commercial fuels from the TAN Pool and transfer them to the Idaho Chemical Processing Plant (ICPP) for interim dry storage until an alternate storage location other than at the INEL, or a permanent federal spent nuclear fuel (SNF) repository is available. The TAN Pool would be drained and placed in an industrially and radiologically safe condition for refurbishment or eventual decommissioning. This environmental assessment (EA) identifies and evaluates environmental impacts associated with (1) constructing an Interim Storage System (ISS) at ICPP; (2) removing the TMI and commercial fuels from the pool and transporting them to ICPP for placement in an ISS, and (3) draining and stabilizing the TAN Pool. Miscellaneous hardware would be removed and decontaminated or disposed of in the INEL Radioactive Waste Management Complex (RWMC). This EA also describes the environmental consequences of the no action alternative

  5. RNA precursor pool metabolism and RNA synthesis in X-irradiated Tetrahymena

    International Nuclear Information System (INIS)

    Stephens, R.E.; Paul, I.J.; Zimmerman, A.M.

    1976-01-01

    The incorporation of a radioactive RNA precursor ( 3 H-uridine) has been used in many studies as an index for measuring the synthesis of RNA, yet there is a distinct possibility that the results so obtained were significantly influenced by radiation-induced effects on the metabolism of this precursor into UTP (the primary immediate precursor of RNA) before its incorporation into RNA. A direct examination was therefore undertaken of the effects of X-irradiation on the metabolism of 3 H-uridine and its relationship to RNA synthesis as determined by incorporation. X-irradiation of logarithmically growing Tetrahymena pyriformis caused a dose-dependent depression of total cellular RNA synthesis. Ribosomal RNA (which comprises about 80 per cent of total cellular RNA) synthesis was also depressed by X-irradiation in a dose-dependent manner. Measurements of the levels of radioactivity present in the UTP precursor pool of both irradiated and unirradiated cells were obtained by means of DEAE-cellulose column chromatography of the extracted free nucleotides. Metabolism of 3 H-uridine into UMP, UDP and UTP was depressed by 40%, 26% and 27% respectively, whereas incorporation of 3 H-uridine into RNA was depressed by 77%. The results show that about one-third of the observed (apparent) depression in RNA synthesis was due to radiation-induced effects on the precursor pool, and the remaining two-thirds due to some definite effect of radiation at the transcription level leading to depressed synthesis of RNA. (U.K.)

  6. Structural analysis of the reactor pool for the RRRP

    International Nuclear Information System (INIS)

    Alberro, J.G.; Abbate, A.D.

    2005-01-01

    The purpose of the present document is to describe the structural design of the Reactor Pool relevant to the RRRP (Replacement Research Reactor Project) for the Australian Nuclear Science and Technology Organisation. The structural analysis required coordinated design, engineering, analysis, and fabrication efforts. The pool has been designed, manufactured, and inspected following as guideline the ASME Boiler and Pressure Vessel Code, which defines the requirements for the pool to withstand hydrostatic and mechanical forces, ensuring its integrity throughout its lifetime. Standard off-the-shelf finite element programs (Nastran and Ansys codes) were used to evaluate the pool and further qualify the design and its construction. Both global and local effect analyses were carried out. The global analysis covers the structural integrity of the pool wall (6 mm thick) considering the different load states acting on it, namely hydrostatic pressure, thermal expansion, and seismic event. The local analysis evaluates the structural behaviour of the pool at specific points resulting from the interaction among components. It is confirmed that maximum stresses and displacements fall below the allowable values required by the ASME Boiler and Pressure Vessel Code. The water pressure analysis was validated by means of a hydrostatic test. (authors)

  7. PIV measurements of turbulent jet and pool mixing produced by a steam jet discharge in a subcooled water pool

    International Nuclear Information System (INIS)

    Choo, Yeon Jun; Song, Chul-Hwa

    2010-01-01

    This experimental research is on the fluid-dynamic features produced by a steam injection into a subcooled water pool. The relevant phenomena could often be encountered in water cooled nuclear power plants. Two major topics, a turbulent jet and the internal circulation produced by a steam injection, were investigated separately using a particle image velocimetry (PIV) as a non-intrusive optical measurement technique. Physical domains of both experiments have a two-dimensional axi-symmetric geometry of which the boundary and initial conditions can be readily and well defined. The turbulent jet experiments with the upward discharging configuration provide the parametric values for quantitatively describing a turbulent jet such as the self-similar velocity profile, central velocity decay, spreading rate, etc. And in the internal circulation experiments with the downward discharging configuration, typical flow patterns in a whole pool region are measured in detail, which reveals both the local and macroscopic characteristics of the mixing behavior in a pool. This quantitative data on the condensing jet-induced mixing behavior in a pool could be utilized as benchmarking for a CFD simulation of relevant phenomena.

  8. Experience on Maintenance of Thai Research Reactor's 'Small-Section' Pool

    International Nuclear Information System (INIS)

    Tippayakul, Chanatip

    2013-01-01

    The reactor pool of TRR-1/M1 has been used since 1962 when the reactor building was constructed. Periodic maintenance of the reactor pool has been conducted by cleaning the pool surface and re-painting with epoxy coating. The TRR-1/M1 pool basically consists of two sections referred as 'large-section' and 'small-section'. The latest re-painting activity of the 'large-section' pool was performed in 2006 but the 'small-section' pool had not been re-painted for more than 10 years. Therefore, to assure that the 'small-section' pool can maintain leak-proof condition, the re-painting of the 'small-section' pool was performed in the early 2012. A project team was organized specially for this project and a detailed execution plan was developed. The project activities include removing foreign objects and highly activated materials from the pool section, cleaning, inspecting, re-painting the pool surface and testing for water leaks. Preparation of the repainting activities had begun 2 years in advance. During the time, the reactor core had been relocated to operate in the large-section pool away from the working area in order to minimize radioactivity. The challenge of this project was to handle 4 sets of highly radioactive bolts and nuts which support the weight of the 'void tank' irradiation facility. These bolts and nuts were made from stainless steel and had been in the flux region since the installation of the 'void tank' irradiation facility approximately 30 years ago. Dose rate measurement at the contacts of these bolts and nuts were found to be in the range of 10 . 20 R/hr. The strategy to minimize the dose rate of the workers to conduct the pool repainting in the area was to remove the bolts and nuts and replace with new ones before entering the area. Special tools were improvised in order to remove the bolts and nuts under water. During the execution of the project, close radiation monitoring was performed by the radiation protection team. The project was conducted

  9. Phytobenthic communities of intertidal rock pools in the eastern islands of Azores and their relation to position on shore and pool morphology

    OpenAIRE

    Wallenstein, Francisco; Peres, Sara D.; Xavier, Emanuel D.; Neto, Ana I.

    2010-01-01

    This study aimed to characterize algal composition inside rock-pools from two islands of the Azores archipelago (São Miguel and Santa Maria) and relate it to shore height and pool morphology. Pools were categorized as upper, medium and lower intertidal according to the surrounding communities. Maximum depth and surface area were used to reflect morphology and qualitative sampling to evaluate algal species richness. PRIMER software assessed the similarity across islands, sites, shore height...

  10. 16 CFR 1633.5 - Prototype pooling and confirmation testing requirements.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Prototype pooling and confirmation testing... Prototype pooling and confirmation testing requirements. (a) Prototype pooling. One or more manufacturers may rely on a qualified prototype produced by another manufacturer or prototype developer provided...

  11. Non-electric applications of pool-type nuclear reactors

    International Nuclear Information System (INIS)

    Adamov, E.O.; Cherkashov, Yu.M.; Romenkov, A.A.

    1997-01-01

    This paper recommends the use of pool-type light water reactors for thermal energy production. Safety and reliability of these reactors were already demonstrated to the public by the long-term operation of swimming pool research reactors. The paper presents the design experience of two projects: Apatity Underground Nuclear Heating Plant and Nuclear Sea-Water Desalination Plant. The simplicity of pool-type reactors, the ease of their manufacturing and maintenance make this type of a heat source attractive to the countries without a developed nuclear industry. (author). 6 figs, 1 tab

  12. Electricity prices and generator behaviour in gross pool electricity markets

    International Nuclear Information System (INIS)

    O'Mahoney, Amy; Denny, Eleanor

    2013-01-01

    Electricity market liberalisation has become common practice internationally. The justification for this process has been to enhance competition in a market traditionally characterised by statutory monopolies in an attempt to reduce costs to end-users. This paper endeavours to see whether a pool market achieves this goal of increasing competition and reducing electricity prices. Here the electricity market is set up as a sealed bid second price auction. Theory predicts that such markets should result with firms bidding their marginal cost, thereby resulting in an efficient outcome and lower costs to consumers. The Irish electricity system with a gross pool market experiences among the highest electricity prices in Europe. Thus, we analyse the Irish pool system econometrically in order to test if the high electricity prices seen there are due to participants bidding outside of market rules or out of line with theory. Overall we do not find any evidence that the interaction between generator and the pool in the Irish electricity market is not efficient. Thus, the pool element of the market structure does not explain the high electricity prices experienced in Ireland. - Highlights: • We consider whether a gross pool achieves competitive behaviour. • We analyse the Irish pool system econometrically. • Results indicate the Irish pool system appears to work efficiently. • Generators appear to be bidding appropriately

  13. Addressing data privacy in matched studies via virtual pooling.

    Science.gov (United States)

    Saha-Chaudhuri, P; Weinberg, C R

    2017-09-07

    Data confidentiality and shared use of research data are two desirable but sometimes conflicting goals in research with multi-center studies and distributed data. While ideal for straightforward analysis, confidentiality restrictions forbid creation of a single dataset that includes covariate information of all participants. Current approaches such as aggregate data sharing, distributed regression, meta-analysis and score-based methods can have important limitations. We propose a novel application of an existing epidemiologic tool, specimen pooling, to enable confidentiality-preserving analysis of data arising from a matched case-control, multi-center design. Instead of pooling specimens prior to assay, we apply the methodology to virtually pool (aggregate) covariates within nodes. Such virtual pooling retains most of the information used in an analysis with individual data and since individual participant data is not shared externally, within-node virtual pooling preserves data confidentiality. We show that aggregated covariate levels can be used in a conditional logistic regression model to estimate individual-level odds ratios of interest. The parameter estimates from the standard conditional logistic regression are compared to the estimates based on a conditional logistic regression model with aggregated data. The parameter estimates are shown to be similar to those without pooling and to have comparable standard errors and confidence interval coverage. Virtual data pooling can be used to maintain confidentiality of data from multi-center study and can be particularly useful in research with large-scale distributed data.

  14. Presence and select determinants of organophosphate flame retardants in public swimming pools

    International Nuclear Information System (INIS)

    Teo, Tiffany L.L.; Coleman, Heather M.; Khan, Stuart J.

    2016-01-01

    The occurrence of five organophosphate flame retardants (PFRs) consisting of tributyl phosphate (TNBP), tris(2-chloroethyl) phosphate (TCEP), tris(1-chloro-2-propyl) phosphate (TCIPP), tris(1.3-dichloro-2-propyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP) in swimming pools were investigated. Fifteen chlorinated public swimming pools were sampled, including indoor pools, outdoor pools and spa pools. The analyses were carried out using isotope dilution gas chromatography tandem mass spectrometry. All five PFRs were detected in swimming pool waters with concentrations ranging from 5–27 ng/L (TNBP), 7–293 ng/L (TCEP), 62–1180 ng/L (TCIPP), 10–670 ng/L (TDCIPP) and 8–132 ng/L (TPHP). The concentrations of PFRs were generally higher in indoor swimming pools compared to outdoor swimming pools. In municipal water supplies, used to fill the swimming pools in three of the sampling locations, the five PFRs were all below the limit of quantifications, eliminating this as the source. Potential leaching of PFRs from commonly used swimming equipment, including newly purchased kickboards and swimsuits was investigated. These experiments revealed that PFRs leached from swimsuits, and may be a source of PFRs in swimming pools. A quantitative risk assessment revealed that the health risk to PFRs via swimming pools was generally low and below commonly applied health risk benchmarks. - Highlights: • TNBP, TCEP, TCIPP, TDCIPP and TPHP were detected in chlorinated swimming pools. • PFRs were below the LOQ in fill water samples collected from 3 locations. • TCIPP was observed to have the highest concentrations in swimming pools. • PFRs are leaching from swimsuits and may be a source in swimming pools. • Health risks through oral and dermal exposure to PFRs in swimming pools were low.

  15. Presence and select determinants of organophosphate flame retardants in public swimming pools

    Energy Technology Data Exchange (ETDEWEB)

    Teo, Tiffany L.L., E-mail: tiffany.teo@unsw.edu.au [UNSW Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Kensington NSW 2052 (Australia); Coleman, Heather M., E-mail: h.coleman@ulster.ac.uk [Nanotechnology and Integrated BioEngineering Centre, School of Engineering, University of Ulster, Jordanstown, County Antrim BT37 0QB, Northern Ireland (United Kingdom); Khan, Stuart J., E-mail: s.khan@unsw.edu.au [UNSW Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Kensington NSW 2052 (Australia)

    2016-11-01

    The occurrence of five organophosphate flame retardants (PFRs) consisting of tributyl phosphate (TNBP), tris(2-chloroethyl) phosphate (TCEP), tris(1-chloro-2-propyl) phosphate (TCIPP), tris(1.3-dichloro-2-propyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP) in swimming pools were investigated. Fifteen chlorinated public swimming pools were sampled, including indoor pools, outdoor pools and spa pools. The analyses were carried out using isotope dilution gas chromatography tandem mass spectrometry. All five PFRs were detected in swimming pool waters with concentrations ranging from 5–27 ng/L (TNBP), 7–293 ng/L (TCEP), 62–1180 ng/L (TCIPP), 10–670 ng/L (TDCIPP) and 8–132 ng/L (TPHP). The concentrations of PFRs were generally higher in indoor swimming pools compared to outdoor swimming pools. In municipal water supplies, used to fill the swimming pools in three of the sampling locations, the five PFRs were all below the limit of quantifications, eliminating this as the source. Potential leaching of PFRs from commonly used swimming equipment, including newly purchased kickboards and swimsuits was investigated. These experiments revealed that PFRs leached from swimsuits, and may be a source of PFRs in swimming pools. A quantitative risk assessment revealed that the health risk to PFRs via swimming pools was generally low and below commonly applied health risk benchmarks. - Highlights: • TNBP, TCEP, TCIPP, TDCIPP and TPHP were detected in chlorinated swimming pools. • PFRs were below the LOQ in fill water samples collected from 3 locations. • TCIPP was observed to have the highest concentrations in swimming pools. • PFRs are leaching from swimsuits and may be a source in swimming pools. • Health risks through oral and dermal exposure to PFRs in swimming pools were low.

  16. Compact fuel storage rack for fuel pools

    International Nuclear Information System (INIS)

    Parras, F.; Louvat, J.P.

    1986-01-01

    ETS LEMER and FRAMATOME propose a new compact storage rack. This rack permits a considerable increase of the storage capacity of cooling pools. A short description of the structure and the components is presented, to propose racks that are: . Inalterable, . Compact, . Insensitive to earthquakes. Installation in pools already in operation is simplified by their light structure and the bearing device [fr

  17. Income pooling within families

    DEFF Research Database (Denmark)

    Bonke, Jens; Uldall-Poulsen, Hans

    This paper analyses the phenomenon of income-pooling by applying the Danish household expenditure survey, merged with authoritative register information. Responses to additional questions on income sharing among 1696 couples also allows us to analyses whether the intra-household distribution...

  18. Health impact of disinfection by-products in swimming pools

    Directory of Open Access Journals (Sweden)

    Cristina M. Villanueva

    2012-12-01

    Full Text Available This article is focused on the epidemiological evidence on the health impacts related to disinfection by-products (DBPs in swimming pools, which is a chemical hazard generated as an undesired consequence to reduce the microbial pathogens. Specific DBPs are carcinogenic, fetotoxic and/or irritant to the airways according to experimental studies. Epidemiological evidence shows that swimming in pools during pregnancy is not associated with an increased risk of reproductive outcomes. An epidemiological study suggested an increased risk of bladder cancer with swimming pool attendance, although evidence is inconclusive. A higher prevalence of respiratory symptoms including asthma is found among swimming pool workers and elite swimmers, although the causality of this association is unclear. The body of evidence in children indicates that asthma is not increased by swimming pool attendance. Overall, the available knowledge suggests that the health benefits of swimming outweigh the potential health risks of chemical contamination. However, the positive effects of swimming should be enhanced by minimising potential risks.

  19. Characteristics of fission product release from a molten pool

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2001-01-01

    The volatile fission products are released from the debris pool, while the less volatile fission products tend to remain as condensed phases because of their low vapor pressure. The release of noble gases and the volatile fission products is dominated by bubble dynamics. The release of the less volatile fission products from the pool can be analyzed based on mass transport through a liquid with the convection flow. The physico-numerical models were orchestrated from existing submodels in various disciplines of engineering to estimate the released fraction of fission products from a molten pool. It was assumed that the pool has partially filled hemispherical geometry. For the high pool pressure, the diameter of the bubbles at detachment was calculated utilizing the Cole and Shulman correlation with the effect of system pressure. Sensitivity analyses were performed and results of the numerical calculations were compared with analysis results for the TMI-2 accident. (author)

  20. 13 CFR 120.631 - Suspension or termination of Pool Assembler.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Suspension or termination of Pool Assembler. 120.631 Section 120.631 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market Pool Assemblers § 120.631 Suspension or termination of Pool Assembler. (a...

  1. Estimation of heat transfer and heat source in a molten pool

    Energy Technology Data Exchange (ETDEWEB)

    Yun, J.I.; Suh, K.Y.; Kang, C.S. [Seoul National Univ., Dept. of Nuclear Engineering (Korea, Republic of)

    2001-07-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the pool. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool was estimated by product of the mass concentration and energy conversion factor of each fission product. For the calculation of heat generation rate in the pool, twenty-nine (29) elements were chosen and classified by their chemical properties. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis was performed for the TMI-2 accident. The pool is assumed to be a partially filled hemispherical geometry, 1.45 m in radius and 32,700 kg in mass. The change of pool geometry during the numerical calculation was neglected. The peak temperature sizably decreased by about 60 K as the fission products were released from the pool. (author)

  2. Estimation of heat transfer and heat source in a molten pool

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2001-01-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the pool. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool was estimated by product of the mass concentration and energy conversion factor of each fission product. For the calculation of heat generation rate in the pool, twenty-nine (29) elements were chosen and classified by their chemical properties. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis was performed for the TMI-2 accident. The pool is assumed to be a partially filled hemispherical geometry, 1.45 m in radius and 32,700 kg in mass. The change of pool geometry during the numerical calculation was neglected. The peak temperature sizably decreased by about 60 K as the fission products were released from the pool. (author)

  3. DATA-POOL : a direct-access data base for large-scale nuclear codes

    International Nuclear Information System (INIS)

    Yamano, Naoki; Koyama, Kinji; Naito, Yoshitaka; Minami, Kazuyoshi.

    1991-12-01

    A direct-access data base DATA-POOL has been developed for large-scale nuclear codes. The data can be stored and retrieved with specifications of simple node names, by using the DATA-POOL access package written in the FORTRAN 77 language. A management utility POOL for the DATA-POOL is also provided. A typical application of the DATA-POOL is shown to the RADHEAT-V4 code system developed for performing safety analyses of radiation shielding. Many samples and error messages are also noted to apply the DATA-POOL for the other code systems. This report is provided for a manual of DATA-POOL. (author)

  4. Seasonal variation in Chironomid emergence from coastal pools

    Directory of Open Access Journals (Sweden)

    Alexander T. Egan

    2015-07-01

    Full Text Available Understanding the phenology of emergences can be useful in determining seasonal chironomid life cycle patterns, which are often influenced by ice cover and temperature in cold climates. Lake Superior is the largest lake in North America and with a mean surface temperature of 3.9 °C influences regional climate. Coastal pools at Isle Royale, a wilderness archipelago in the northern part of the lake, occur in dense patches on low-gradient volcanic bedrock between the lakeshore and forest, creating variable microhabitats for Chironomidae. Four sites were sampled monthly from April to October, 2010. Surface-floating pupal exuviae were collected from a series of pools in two zones: a lower zone near the lake influenced by wave splash, and an upper zone near the forest and influenced by upland runoff. We used Jaccard’s and Whittaker’s diversity indexes to test community similarity across months. Temperature loggers in pools collected hourly readings for most of the study. Assemblage emergences were stable in upper pools, with significant similarity across late spring and summer months. Assemblages were seasonally variable in lower pools, with significant dissimilarity across spring, summer, and fall months. Few species in either zone were unique to spring or fall months. However, many summer species in the splash zone had a narrow emergence period occurring during calm weather following distinct increases in mean water temperature. Regardless of input of cold lake water to the lower zone, pools from both zones generally had corresponding temperature trends.

  5. Stabilization of reactor fuel storage pool-TTP

    International Nuclear Information System (INIS)

    Sevigny, G.

    1994-10-01

    The proposed work includes evaluating standard and improved technologies an designing an integrated demonstration system to clean the water and sludge the fuel storage pools. The water released would meet drinking water standards and tritium standards. The volume of radioactive sludge would be reduced by partial separation of the sludge and radionuclides and eventual solidification of the hazardous and radioactive waste. The scope of the wo includes a survey of needs and applicable technologies, system engineering evaluation, conceptual design, detailed design, fabrication of the integrat demonstration system, and testing of the system. The survey task will locate potential specific customers within the DOE complex, and outside of the DOE complex throughout the United States, that be able to utilize the narrowly focused technology to stabilize/shutdown reactor fuel storage pools, responsible parties will be located and asked respond to a survey about their specific process requirements. Literature searches will be run through technical and scientific databases to locate technologies that may be an improvement over the standard baselined technol for cleanup of radioactively-contaminated pools. Systems engineering will provide decision analysis support for the development, evaluation, design, test functions of the treatment of pool water and sludge

  6. Stabilization of reactor fuel storage pool-TTP

    Energy Technology Data Exchange (ETDEWEB)

    Sevigny, G.

    1994-10-01

    The proposed work includes evaluating standard and improved technologies an designing an integrated demonstration system to clean the water and sludge the fuel storage pools. The water released would meet drinking water standards and tritium standards. The volume of radioactive sludge would be reduced by partial separation of the sludge and radionuclides and eventual solidification of the hazardous and radioactive waste. The scope of the wo includes a survey of needs and applicable technologies, system engineering evaluation, conceptual design, detailed design, fabrication of the integrat demonstration system, and testing of the system. The survey task will locate potential specific customers within the DOE complex, and outside of the DOE complex throughout the United States, that be able to utilize the narrowly focused technology to stabilize/shutdown reactor fuel storage pools, responsible parties will be located and asked respond to a survey about their specific process requirements. Literature searches will be run through technical and scientific databases to locate technologies that may be an improvement over the standard baselined technol for cleanup of radioactively-contaminated pools. Systems engineering will provide decision analysis support for the development, evaluation, design, test functions of the treatment of pool water and sludge.

  7. The effect of a total rewards strategy on school teachers’ retention

    OpenAIRE

    Boitomelo Makhuzeni; E. Nicolene Barkhuizen

    2015-01-01

    Orientation: South African schools are facing significant challenges to retain a talented pool of school teachers. A total rewards strategy could assist schools to reduce teacher turnover. Research purpose: The aim of this study was to determine the effect of a total rewards strategy on the turnover intentions of school teachers in the North-West province. Motivation: The under supply of quality teachers has negative consequences for both school pupils and the larger community. Re...

  8. Sodium/water pool-deposit bed model of the CONACS code

    International Nuclear Information System (INIS)

    Peak, R.D.

    1983-01-01

    A new Pool-Bed model of the CONACS (Containment Analysis Code System) code represents a major advance over the pool models of other containment analysis code (NABE code of France, CEDAN code of Japan and CACECO and CONTAIN codes of the United States). This new model advances pool-bed modeling because of the number of significant materials and processes which are included with appropriate rigor. This CONACS pool-bed model maintains material balances for eight chemical species (C, H 2 O, Na, NaH, Na 2 O, Na 2 O 2 , Na 2 CO 3 and NaOH) that collect in the stationary liquid pool on the floor and in the desposit bed on the elevated shelf of the standard CONACS analysis cell

  9. Natural convection heat transfer in the molten metal pool

    International Nuclear Information System (INIS)

    Park, R.J.; Kim, S.B.; Kim, H.D.; Choi, S.M.

    1997-01-01

    Analytical studies using the FLOW-3D computer program have been performed on natural convection heat transfer of a high density molten metal pool, in order to evaluate the coolability of the corium pool. The FLOW-3D results on the temperature distribution and the heat transfer rate in the molten metal pool region have been compared and evaluated with the experimental data. The FLOW-3D results have shown that the developed natural convection flow contributes to the solidified crust formation of the high density molten metal pool. The present FLOW-3D results, on the relationship between the Nusselt number and the Rayleigh number in the molten metal pool region, are more similar to the calculated results of Globe and Dropkin's correlation than any others. The natural convection heat transfer in the low aspect ratio case is more substantial than that in the high aspect ratio case. The FLOW-3D results, on the temperature profile and on the heat transfer rate in the molten metal pool region, are very similar to the experimental data. The heat transfer rate of the internal heat generation case is higher than that of the bottom heating case at the same heat supply condition. (author)

  10. Measurement of argon concentrations in a TRIGA Mark-III pool

    Energy Technology Data Exchange (ETDEWEB)

    Simms, R [California State University, Northridge, CA (United States)

    1974-07-01

    Argon-41, the principal radioactive effluent from a pool type reactor during normal operation, is produced by the {sup 40}A (n,{gamma}) reaction. The reactant, {sup 40}A, is introduced into the pool water by contact with the air. Reduction in radioactive argon release can be accomplished by reducing the concentration of dissolved {sup 40}A and retaining the {sup 41}A within the pool. However, little data were available concerning the mechanisms of argon introduction, production, retention, and release from a reactor pool. Experiments have therefore been performed at the Torrey Pines TRIGA Mark-III Reactor to develop techniques to sample dissolved argon and to provide data on argon concentrations in the pool for release modeling studies. Significant results for argon dissolved at different pool depths can only be obtained if the water samples are sealed at the point of collection. A special handling tool was developed to perform this remote operation. Pool samples were counted for {sup 41}A soon after collection with a NaI spectrometer. After allowing one day for decay of {sup 41}A, the concentration of {sup 40}A in the water sample was determined by neutron activation analysis. In each case, the 1.29 MeV gamma-ray peak of {sup 41}A was used. Interference from the 1.37 MeV {sup 24}Na peak was considered and its effect subtracted after determining {sup 24}Na content from the 2.75 MeV {sup 24}Na peak and a sodium standard. A Ge(Li) detector was tried and found to eliminate the problem, but it introduced an unacceptable geometrical effect dependent on bubble size within the sample bottles. Samples were taken from the 27 ft deep TRIGA pool at various locations. Results were obtained for samples taken on several different days along the same vertical line about 3-1/2 ft from the reactor centerline. Temperature measurements along this vertical traverse indicated a sharp temperature gradient at about 15 ft below the surface ({approx}6 ft above the top of the reactor). The

  11. Mathematical-programming approaches to test item pool design

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; van der Linden, Willem J.; Ariel, A.

    2002-01-01

    This paper presents an approach to item pool design that has the potential to improve on the quality of current item pools in educational and psychological testing andhence to increase both measurement precision and validity. The approach consists of the application of mathematical programming

  12. Horizontal above-rack pool storage

    International Nuclear Information System (INIS)

    Moscardini, R.L.

    1993-08-01

    This report describes a unique method for storing spent, six year out of core, fuel at a prototypical PWR nuclear power station. The study describes a conceptual design, with favorable structural, thermal and criticality technical evaluations. However, economic considerations and licensing risks are judged to be less favorable. The concept study prescribes a fuel over fuel arrangement in an existing Spent Fuel Pool (SFP) with full maintenance of ALARA principles. This concept study is specific to a prototypical pool design, but may easily be projected to other nuclear facilities with other SFP conditions. For the prototypical PWR, the conceptual fuel bridge design will store over 200 additional fuel assemblies without significant facility modifications and for an indefinite time period

  13. Observations of Cold Pool Properties during GoAmazon2014/5

    Science.gov (United States)

    Mayne, S. L.; Schumacher, C.; MacDonald, L.; Turner, D. D.

    2017-12-01

    Convectively generated cold pools are instrumental in both the development of the sub-cloud layer and the organization of deep convection. Despite this, analyses of cold pools in the tropics are constrained by a lack of observational data; insight into the phenomena therefore relies heavily on numerical models. GoAmazon2014/5, a 2-year DOE-sponsored field campaign centered on Manacapuru, Brazil in the central Amazon, provides a unique opportunity to characterize tropical cold pools and allows for the comparison of observational data with theoretical results from model cold pool simulations and parameterizations. This investigation analyzes radar, disdrometer, and profiler measurements at the DOE mobile facility site to study tropical cold pool characteristics. The Brazilian military (SIPAM) operational S-band radar in Manaus is used to provide a broad context of convective systems, while measurements from Parsivel disdrometers are used to assess drop-size distributions (DSDs) at the surface. A unique aspect of this research is the use of the Atmospheric Emitted Radiance Interferometer (AERI) instrument, which utilizes down-welling IR measurements to obtain vertical profiles of thermodynamic quantities such as temperature and water vapor in the lowest few km of the atmosphere. Combined with surface observations and sounding data, these datasets will result in a thorough investigation of the horizontal and vertical characteristics of cold pools over the tropical rain forest. Preliminary analyses of 20 events reveal a mean cold pool height of 220 m and a mean radius of approximately 8.5 km. The average cold pool experienced a temperature (specific humidity) decrease of approximately 1 K (0.4 g/kg) at the surface. The temperature decrease is consistent with modeling studies and limited observations from previous studies over the tropics. The small decrease in specific humidity is attributed to the high moisture content within the cold pools. AERI retrievals of

  14. Sustainability of common pool resources.

    Science.gov (United States)

    Timilsina, Raja Rajendra; Kotani, Koji; Kamijo, Yoshio

    2017-01-01

    Sustainability has become a key issue in managing natural resources together with growing concerns for capitalism, environmental and resource problems. We hypothesize that the ongoing modernization of competitive societies, which we refer to as "capitalism," affects human nature for utilizing common pool resources, thus compromising sustainability. To test this hypothesis, we design and implement a set of dynamic common pool resource games and experiments in the following two types of Nepalese areas: (i) rural (non-capitalistic) and (ii) urban (capitalistic) areas. We find that a proportion of prosocial individuals in urban areas is lower than that in rural areas, and urban residents deplete resources more quickly than rural residents. The composition of proself and prosocial individuals in a group and the degree of capitalism are crucial in that an increase in prosocial members in a group and the rural dummy positively affect resource sustainability by 65% and 63%, respectively. Overall, this paper shows that when societies move toward more capitalistic environments, the sustainability of common pool resources tends to decrease with the changes in individual preferences, social norms, customs and views to others through human interactions. This result implies that individuals may be losing their coordination abilities for social dilemmas of resource sustainability in capitalistic societies.

  15. Single-Track Melt-Pool Measurements and Microstructures in Inconel 625

    Science.gov (United States)

    Ghosh, Supriyo; Ma, Li; Levine, Lyle E.; Ricker, Richard E.; Stoudt, Mark R.; Heigel, Jarred C.; Guyer, Jonathan E.

    2018-02-01

    We use single-track laser melting experiments and simulations on Inconel 625 to estimate the dimensions and microstructure of the resulting melt pool. Our work is based on a design-of-experiments approach which uses multiple laser power and scan speed combinations. Single-track experiments generated melt pools of certain dimensions that showed reasonable agreement with our finite-element calculations. Phase-field simulations were used to predict the size and segregation of the cellular microstructure that formed along the melt-pool boundaries for the solidification conditions that changed as a function of melt-pool dimensions.

  16. Single-Track Melt-Pool Measurements and Microstructures in Inconel 625

    Science.gov (United States)

    Ghosh, Supriyo; Ma, Li; Levine, Lyle E.; Ricker, Richard E.; Stoudt, Mark R.; Heigel, Jarred C.; Guyer, Jonathan E.

    2018-06-01

    We use single-track laser melting experiments and simulations on Inconel 625 to estimate the dimensions and microstructure of the resulting melt pool. Our work is based on a design-of-experiments approach which uses multiple laser power and scan speed combinations. Single-track experiments generated melt pools of certain dimensions that showed reasonable agreement with our finite-element calculations. Phase-field simulations were used to predict the size and segregation of the cellular microstructure that formed along the melt-pool boundaries for the solidification conditions that changed as a function of melt-pool dimensions.

  17. 3-dimensional thermohydraulic analysis of KALIMER reactor pool during unprotected accidents

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Bum; Hahn Do Hee

    2003-01-01

    During a normal reactor scram, the heat generation is reduced almost instantaneously while the coolant flow rate follows the pump coastdown. This mismatch between power and flow results in a situation where the core flow entering the hot pool is at a lower temperature than the temperature of the bulk pool sodium. This temperature difference leads to thermal stratification. Thermal stratification can occur in the hot pool region if the entering coolant is colder than the existing hot pool coolant and the flow momentum is not large enough to overcome the negative buoyancy force. Since the fluid of hot pool enters IHXs, the temperature distribution of hot pool can alter the overall system response. Hence, it is necessary to predict the pool coolant temperature distribution with sufficient accuracy to determine the inlet temperature conditions for the IHXs and its contribution to the net buoyancy head. Therefore, two-dimensional hot pool thermohydraulic model named HP2D has been developed. In this report code-to-code comparison analysis between HP2D and COMMIX-1AR/P has been performed in the case of steady-state and UTOP.

  18. Study on velocity distribution in a pool by submersible mixers

    International Nuclear Information System (INIS)

    Tian, F; Shi, W D; Lu, X N; Chen, B; Jiang, H

    2012-01-01

    To study the distribution of submersible mixers and agitating effect in the sewage treatment pool, Pro/E software was utilized to build the three-dimensional model. Then, the large-scale computational fluid dynamics software FLUENT6.3 was used. ICEM software was used to build unstructured grid of sewage treatment pool. After that, the sewage treatment pool was numerically simulated by dynamic coordinate system technology and RNG k-ε turbulent model and PIOS algorithm. The macro fluid field and each section velocity flow field distribution were analyzed to observe the efficiency of each submersible mixer. The average velocity and mixing area in the sewage pool were studied simultaneously. Results show that: the preferred project B, two submersible mixers speed is 980 r/min, and setting angles are all 30°. Fluid mixing area in the pool has reached more than 95%. Under the action of two mixers, the fluid in the sewage pool form a continuous circulating water flow. The fluid is mixed adequately and average velocity of fluid in the pool is at around 0.241m/s, which agreed with the work requirements. Consequently it can provide a reference basis for practical engineering application of submersible mixers by using this method.

  19. The radionuclides of primary coolant in HANARO and the recent activities performed to reduce the radioactivity or reactor pool water

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Minjin [HANARO Research Reactor Centre, Korea Atomic Energy Research Inst., Taejon (Korea, Republic of)

    1998-10-01

    In HANARO reactor, there have been activities to identify the principal radionuclides and to quantify them under the normal operation. The purposes of such activities were to establish the measure by which we can reduce the radioactivity of the reactor pool water and detect, in early stage, the abnormal symptoms due to the leakage of radioactive materials from the irradiation sample or the damage of the nuclear fuel, etc. The typical radionuclides produced by the activation of reactor coolant are N{sup 16} and Ar{sup 41}. The radionuclides produced by the activation of the core structural material consist of Na{sup 24}, Mn{sup 56}, and W{sup 187}. Of the various radionuclides, governing the radiation level at the pool surface are Na{sup 24}, Ar{sup 41}, Mn{sup 58}, and W{sup 187}. By establishing the hot water layer system on the pool surface, we expected that the radionuclides such as Ar{sup 41} and Mn{sup 56} whose half-life are relatively short could be removed to a certain extent. Since the content of radioactivity of Na{sup 24} occupies about 60% of the total radioactivity, we assumed that the total radiation level would be greatly reduced if we could decrease the radiation level of Na{sup 24}. However the actual radiation level has not been reduced as much as we expected. Therefore, some experiments have been carried out to find the actual causes afterwards. What we learned through the experiments are that any disturbance in reactor pool water layer causes increase of the pool surface radiation level and even if we maintain the hot water layer well, reactor shutdown will be very much likely to happen once the hot water layer is disturbed. (author)

  20. Pool Boiling CHF in Inclined Narrow Annuli

    International Nuclear Information System (INIS)

    Kang, Myeong Gie

    2010-01-01

    Pool boiling heat transfer has been studied extensively since it is frequently encountered in various heat transfer equipment. Recently, it has been widely investigated in nuclear power plants for application to the advanced light water reactors designs. Through the review on the published results it can be concluded that knowledge on the combined effects of the surface orientation and a confined space on pool boiling heat transfer is of great practical importance and also of great academic interest. Fujita et al. investigated pool boiling heat transfer, from boiling inception to the critical heat flux (CHF, q' CHF ), in a confined narrow space between heated and unheated parallel rectangular plates. They identified that both the confined space and the surface orientation changed heat transfer much. Kim and Suh changed the surface orientation angles of a downward heating rectangular channel having a narrow gap from the downward-facing position (180 .deg.) to the vertical position (90 .deg.). They observed that the CHF generally decreased as the inclination angle (θ ) increased. Yao and Chang studied pool boiling heat transfer in a confined heat transfer for vertical narrow annuli with closed bottoms. They observed that when the gap size ( s ) of the annulus was decreased the effect of space confinement to boiling heat transfer increased. The CHF was occurred at much lower value for the confined space comparing to the unconfined pool boiling. Pool boiling heat transfer in narrow horizontal annular crevices was studied by Hung and Yao. They concluded that the CHF decreased with decreasing gap size of the annuli and described the importance of the thin film evaporation to explain the lower CHF of narrow crevices. The effect of the inclination angle on the CHF on countercurrent boiling in an inclined uniformly heated tube with closed bottoms was also studied by Liu et al. They concluded that the CHF reduced with the inclination angle decrease. A study was carried out

  1. Microbial diversity in acidic thermal pools in the Uzon Caldera, Kamchatka.

    Science.gov (United States)

    Mardanov, Andrey V; Gumerov, Vadim M; Beletsky, Alexey V; Ravin, Nikolai V

    2018-01-01

    Microbial communities of four acidic thermal pools in the Uzon Caldera, Kamchatka, Russia, were studied using amplification and pyrosequencing of 16S rRNA gene fragments. The sites differed in temperature and pH: 1805 (60 °C, pH 3.7), 1810 (90 °C, pH 4.1), 1818 (80 °C, pH 3.5), and 1807 (86 °C, pH 5.6). Archaea of the order Sulfolobales were present among the dominant groups in all four pools. Acidilobales dominated in pool 1818 but were a minor fraction at the higher temperature in pool 1810. Uncultivated Archaea of the Hot Thaumarchaeota-related clade were present in significant quantities in pools 1805 and 1807, but they were not abundant in pools 1810 and 1818, where high temperatures were combined with low pH. Nanoarchaeota were present in all pools, but were more abundant in pools 1810 and 1818. A similar abundance pattern was observed for Halobacteriales. Thermophilic Bacteria were less diverse and were mostly represented by aerobic hydrogen- and sulfur-oxidizers of the phylum Aquificae and sulfur-oxidising Proteobacteria of the genus Acidithiobacillus. Thus we showed that extremely acidic hot pools contain diverse microbial communities comprising different metabolic groups of prokaryotes, including putative lithoautotrophs using energy sources of volcanic origin, and various facultative and obligate heterotrophs.

  2. Experimental investigation of particulate debris spreading in a pool

    Energy Technology Data Exchange (ETDEWEB)

    Konovalenko, A., E-mail: kono@kth.se [Division of Nuclear Power Safety, Royal Institute of Technology (KTH) , Roslagstullsbacken 21, Stockholm 106 91 (Sweden); Basso, S., E-mail: simoneb@kth.se [Division of Nuclear Power Safety, Royal Institute of Technology (KTH) , Roslagstullsbacken 21, Stockholm 106 91 (Sweden); Kudinov, P., E-mail: pkudinov@kth.se [Division of Nuclear Power Safety, Royal Institute of Technology (KTH) , Roslagstullsbacken 21, Stockholm 106 91 (Sweden); Yakush, S.E., E-mail: yakush@ipmnet.ru [Institute for Problems in Mechanics of the Russian Academy of Sciences, Ave. Vernadskogo 101 Bldg 1, Moscow 119526 (Russian Federation)

    2016-02-15

    Termination of severe accident progression by core debris cooling in a deep pool of water under reactor vessel is considered in several designs of light water reactors. However, success of this accident mitigation strategy is contingent upon the effectiveness of heat removal by natural circulation from the debris bed. It is assumed that a porous bed will be formed in the pool in the process of core melt fragmentation and quenching. Debris bed coolability depends on its properties and system conditions. The properties of the bed, including its geometry are the outcomes of the debris bed formation process. Spreading of the debris particles in the pool by two-phase turbulent flows induced by the heat generated in the bed can affect the shape of the bed and thus influence its coolability. The goal of this work is to provide experimental data on spreading of solid particles in the pool by large-scale two-phase flow. The aim is to provide data necessary for understanding of separate effects and for development and validation of models and codes. Validated codes can be then used for prediction of debris bed formation under prototypic severe accident conditions. In PDS-P (Particulate Debris Spreading in the Pool) experiments, air injection at the bottom of the test section is employed as a means to create large-scale flow in the pool in isothermal conditions. The test section is a rectangular tank with a 2D slice geometry, it has fixed width (72 mm), adjustable length (up to 1.5 m) and allows water filling to the depth of up to 1 m. Variable pool length and depth allows studying two-phase circulating flows of different characteristic sizes and patterns. The average void fraction in the pool is determined by video recording and subsequent image processing. Particles are supplied from the top of the facility above the water surface. Results of several series of PDS-P experiments are reported in this paper. The influence of the gas flow rate, pool dimensions, particle density

  3. Effect of pool rotation on three-dimensional flow in a shallow annular pool of silicon melt with bidirectional temperature gradients

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Quan-Zhuang; Peng, Lan; Liu, Jia [Key Laboratory of Low-grade Energy Utilization Technologies and Systems of Ministry of Education, College of Power Engineering, Chongqing University, Chongqing, 400044 (China); Wang, Fei, E-mail: penglan@cqu.edu.cn [Chongqing Special Equipment Inspection and Research Institute, Chongqing, 401121 (China)

    2016-08-15

    In order to understand the effect of pool rotation on silicon melt flow with the bidirectional temperature gradients, we conducted a series of unsteady three-dimensional (3D) numerical simulations in a shallow annular pool. The bidirectional temperature gradients are produced by the temperature difference between outer and inner walls as well as a constant heat flux at the bottom. Results show that when Marangoni number is small, a 3D steady flow is common without pool rotation. But it bifurcates to a 3D oscillatory flow at a low rotation Reynolds number. Subsequently, the flow becomes steady and axisymmetric at a high rotation Reynolds number. When the Marangoni number is large, pool rotation can effectively suppress the temperature fluctuation on the free surface, meanwhile, it improves the flow stability. The critical heat flux density diagrams are mapped, and the effects of radial and vertical temperature gradients on the flow are discussed. Additionally, the transition process from the flow dominated by the radial temperature gradient to the one dominated by the vertical temperature gradient is presented. (paper)

  4. 13 CFR 120.1709 - Transfers of Pool Certificates.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Transfers of Pool Certificates. 120.1709 Section 120.1709 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1709...

  5. 13 CFR 120.1714 - Seller's Pool Loan servicing.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan servicing. 120.1714 Section 120.1714 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1714 Seller...

  6. 13 CFR 120.1715 - Seller's Pool Loan liquidation.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan liquidation. 120.1715 Section 120.1715 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1715 Seller...

  7. 13 CFR 120.1713 - Seller's Pool Loan origination.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan origination. 120.1713 Section 120.1713 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1713 Seller...

  8. 13 CFR 120.1717 - Seller's Pool Loan deferments.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan deferments. 120.1717 Section 120.1717 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1717 Seller...

  9. The pool chlorine hypothesis and asthma among boys.

    LENUS (Irish Health Repository)

    Cotter, A

    2012-01-31

    Swimming pool sanitation has largely been concerned with the microbiological quality of pool water, which is normally treated using a number of chlorine products. Recent studies have pointed to the potential hazards of chlorine by-products to the respiratory epithelium, particularly in indoor, poorly ventilated, pools. The aim of our study was to elucidate whether chronic exposure to indoor chlorinated swimming pools was associated with an increased likelihood of the development of asthma in boys. METHODS: The subjects were boys aged between 6 and 12 years. Data was collected by means of parental responses to a standardized asthma questionnaire (ISAAC: International Study of Asthma and Allergies in Childhood), supplemented with additional questions regarding frequency of attendance, number of years attendance, whether the child is a swimming team member. The questionnaire return rate was 71\\/% (n = 121). 23 boys were excluded on the basis that they had asthma before they started swimming (n = 97). There was a significant association between number of years a boy had been swimming and the likelihood of wheezing in the last 12 months (p = 0.009; OR = 1.351; 95% CI = 1.077-1.693) and diagnosed asthma (p = 0.046; OR = 1.299; 95% CI = 1.004-1.506). The greater the number the number of years a boy had been attending an indoor, chlorinated pool, the greater the likelihood of wheezing in the last 12 months or "had asthma". Age, parental smoking habits and being a swimming team member had no association with any of the asthma variables examined. Swimming pool attendance may be a risk factor in asthma in boys.

  10. Evaporation rate measurement in the pool of IEAR-1 reactor

    International Nuclear Information System (INIS)

    Torres, Walmir Maximo; Cegalla, Miriam A.; Baptista Filho, Benedito Dias

    2000-01-01

    The surface water evaporation in pool type reactors affects the ventilation system operation and the ambient conditions and dose rates in the operation room. This paper shows the results of evaporation rate experiment in the pool of IEA-R1 research reactor. The experiment is based on the demineralized water mass variation inside cylindrical metallic recipients during a time interval. Other parameters were measured, such as: barometric pressure, relative humidity, environmental temperature, water temperature inside the recipients and water temperature in the reactor pool. The pool level variation due to water contraction/expansion was calculated. (author)

  11. Phase analysis in gated blood pool tomography

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro

    1984-01-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome. (author)

  12. Reflection of illumination laser from gas metal arc weld pool surface

    International Nuclear Information System (INIS)

    Ma, Xiaoji; Zhang, YuMing

    2009-01-01

    The weld pool is the core of the welding process where complex welding phenomena originate. Skilled welders acquire their process feedback primarily from the weld pool. Observation and measurement of the three-dimensional weld pool surface thus play a fundamental role in understanding and future control of complex welding processes. To this end, a laser line is projected onto the weld pool surface in pulsed gas metal arc welding (GMAW) and an imaging plane is used to intercept its reflection from the weld pool surface. Resultant images of the reflected laser are analyzed and it is found that the weld pool surface in GMAW does specularly reflect the projected laser as in gas tungsten arc welding (GTAW). Hence, the weld pool surface in GMAW is also specular and it is in principle possible that it may be observed and measured by projecting a laser pattern and then intercepting and imaging the reflection from it. Due to high frequencies of surface fluctuations, GMAW requires a relatively short time to image the reflected laser

  13. SBWR PCCS vent phenomena and suppression pool mixing

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, P. [Thermal-Hydraulics Lab., Paul Scherrer Institute, Villigen (Switzerland); Andreani, M. [Nuclear Engineering Lab., Swiss Federal Institute of Technology, Zurich (Switzerland)

    1995-09-01

    The most important phenomena influencing the effectiveness of the pressure suppression capability of the water pool within the Wetwell compartment of the SBWR Containment, during the period of Passive Containment Cooling System (PCCS) venting, have been critically reviewed. In addition, calculations have been carried-out to determine the condensation of the vented steam and the distribution of the energy deposited in the liquid pool. It has been found that a large contribution to the vapour suppression is due to condensation inside the vent pipe. The condensation rate of the steam inside the bubbles, produced at the vent exit, during their rise to the surface, may however be rather low, because of the large size bubbles. This can lead to vapour channelling to the Wetwell gas space. The above comments are likely to be ameliorated if the vent exit is a distributed source or sparger. Due to the large water flow rates within the {open_quotes}bubbly two-phase plume{close_quotes} generated by the gas injection, the water in the pool above the vent exit is likely to be heated nearly isothermally (perfect mixing). The effect of the suppression pool walls would be to enhance the recirculation and, consequently to promote mixing. The large size of the bubbles therein and of the walls on pool mixing are the most severe difficulties in extrapolating the results from scaled experiments to prototypical conditions.

  14. The management of the Spend Fuel Pool Water Quality (1996-2007)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Lee, Eui Gyu; Choi, Ho Young; Choi, Mun Jo; Kim, Hyung Wook; Lee, Mun; Lee, Choong Sung; Hur, Soon Ock; Ahn, Guk Hun

    2008-12-15

    The water quality management of spent fuel storage pool water quality in HANARO is important to prevent the corrosion of nuclear fuel and reactor structure material. The condition of the spent fuel storage pool water has been monitored by measuring the electrical conductivity of the spent fuel storage pool purification system and pH periodically. The status of the spent fuel storage pool water quality management was investigated by using the measured data. taken from 1996 to 2007. In general, the electrical conductivity of the spent fuel storage pool water have been managed within 1 {mu}S/cm which is an operation target of HANARO.

  15. Biomass and carbon pools of disturbed riparian forests

    Science.gov (United States)

    Laura A. B. Giese; W. M. Aust; Randall K. Kolka; Carl C. Trettin

    2003-01-01

    Quantification of carbon pools as affected by forest age/development can facilitate riparian restoration and increase awareness of the potential for forests to sequester global carbon. Riparian forest biomass and carbon pools were quantified for four riparian forests representing different seral stages in the South Carolina Upper Coastal Plain. Three of the riparian...

  16. Solar collectors for swimming pools still going strong

    Energy Technology Data Exchange (ETDEWEB)

    1975-01-01

    According to the opinion of the experts, solar energy heating may be technically 'mature' but the profitability is by no means that far. However, solar systems are a good alternative for heating the water in swimming pools. Four solar collector systems developed by different firms to heat swimming pools, including prices, are presented.

  17. Pooled results from five validation studies of dietary self-report instruments using recovery biomarkers for potassium and sodium intake

    Science.gov (United States)

    We have pooled data from five large validation studies of dietary self-report instruments that used recovery biomarkers as referents to assess food frequency questionnaires (FFQs) and 24-hour recalls. We reported on total potassium and sodium intakes, their densities, and their ratio. Results were...

  18. Anthropogenic impact on amorphous silica pools in temperate soils

    Directory of Open Access Journals (Sweden)

    W. Clymans

    2011-08-01

    Full Text Available Human land use changes perturb biogeochemical silica (Si cycling in terrestrial ecosystems. This directly affects Si mobilisation and Si storage and influences Si export from the continents, although the magnitude of the impact is unknown. A major reason for our lack of understanding is that very little information exists on how land use affects amorphous silica (ASi storage in soils. We have quantified and compared total alkali-extracted (PSia and easily soluble (PSie Si pools at four sites along a gradient of anthropogenic disturbance in southern Sweden. Land use clearly affects ASi pools and their distribution. Total PSia and PSie for a continuous forested site at Siggaboda Nature Reserve (66 900 ± 22 800 kg SiO2 ha−1 and 952 ± 16 kg SiO2 ha−1 are significantly higher than disturbed land use types from the Råshult Culture Reserve including arable land (28 800 ± 7200 kg SiO2 ha−1 and 239 ± 91 kg SiO2 ha−1, pasture sites (27 300 ± 5980 kg SiO2 ha−1 and 370 ± 129 kg SiO2 ha−1 and grazed forest (23 600 ± 6370 kg SiO2 ha−1 and 346 ± 123 kg SiO2 ha−1. Vertical PSia and PSie profiles show significant (p < 0.05 variation among the sites. These differences in size and distribution are interpreted as the long-term effect of reduced ASi replenishment, as well as changes in ecosystem specific pedogenic processes and increased mobilisation of the PSia in disturbed soils. We have also made a first, though rough, estimate of the magnitude of change in temperate continental ASi pools due to human disturbance. Assuming that our data are representative, we estimate that total ASi storage in soils has declined by ca. 10 % since the onset of agricultural development (3000 BCE

  19. Diets high in resistent starch and arabinoxylan modulate digestion processes and SCFA pool size in the large intestine and faecal microbial composition in pigs

    DEFF Research Database (Denmark)

    Nielsen, Tina Skau; Lærke, Helle Nygaard; Theil, Peter Kappel

    2014-01-01

    The effects of a high level of dietary fibre (DF) either as arabinoxylan (AX) or resistant starch (RS) on digestion processes, SCFA concentration and pool size in various intestinal segments and on the microbial composition in the faeces were studied in a model experiment with pigs. A total...... resulted in a 3- to 5-fold higher pool size of butyrate compared with WSD feeding, with the RSD being intermediate (P microbial composition towards butyrogenic...

  20. Branchipodopsis species — specialists of ephemeral rock pools ...

    African Journals Online (AJOL)

    Such rock pools were studied in the Drakensberg region, in the eastern Free State and in south-eastern Botswana. Common features ... While short-range dispersal of floating eggs by overflows is common, long-range dispersal (e.g. by wind) seems to be rare and to be restricted to shallow pools with little vegetation. Limited ...

  1. AE/VCE Unconfirmed Vernal Pools

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset is derived from a project by the Vermont Center for Ecostudies(VCE) and Arrowwood Environmental(AE) to map vernal pools throughout the state of Vermont....

  2. AE/VCE Confirmed Vernal Pools

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset is derived from a project by the Vermont Center for Ecostudies(VCE) and Arrowwood Environmental(AE) to map vernal pools throughout the state of Vermont....

  3. Energy Pooling Upconversion in Free Space and Optical Cavities

    Science.gov (United States)

    LaCount, Michael D.

    The ability to efficiently convert the wavelength of light has value in a wide range of disciplines that include the fields of photovoltaics, plant growth, optics and medicine. The processes by which such transformations are carried out are known as upconversions and downconversions. There are several ways to up/down convert light, each with its own attributes, issues, and competing mechanisms. Most are associated with one-body or two-body processes. Three-body dynamics are also possible though, going by the names of quantum cutting (downconversion) and energy pooling (upconversion). These use virtual excited electronic states to mediate conversions as has been experimentally realized using lanthanide ions embedded in wide bandgap materials. The use of lanthanides to convert light is not ideal due to their relative scarcity, toxicity, and the limited range of light frequencies that can be absorbed and emitted. Organic molecules, on the other hand, are typically non-toxic, are made up of abundant elements, and can be designed with tailored spectral properties. At issue is whether or not they can be used to carry out efficient energy pooling, the central question to be answered in this thesis. The research presented here draws on a perturbative quantum electrodynamics framework previously established for generic energy pooling. It was used to develop a computational methodology for determining the rate of energy pooling and its competing processes. This, in turn, draws on a combination of time-dependent density functional theory, quantum electrodynamics, and perturbation theory to generate the requisite material property data. This computational model was applied to two test systems consisting of stilbene-fluorescein and hexabenzocoronene-oligothiophene. The stilbene-fluorescein system was found to have a maximum energy pooling rate efficiency (as compared to competing processes) of 17% and the hexabenzocoronene-oligothiophene system was found to have a maximum

  4. A Double Evolutionary Pool Memetic Algorithm for Examination Timetabling Problems

    Directory of Open Access Journals (Sweden)

    Yu Lei

    2014-01-01

    Full Text Available A double evolutionary pool memetic algorithm is proposed to solve the examination timetabling problem. To improve the performance of the proposed algorithm, two evolutionary pools, that is, the main evolutionary pool and the secondary evolutionary pool, are employed. The genetic operators have been specially designed to fit the examination timetabling problem. A simplified version of the simulated annealing strategy is designed to speed the convergence of the algorithm. A clonal mechanism is introduced to preserve population diversity. Extensive experiments carried out on 12 benchmark examination timetabling instances show that the proposed algorithm is able to produce promising results for the uncapacitated examination timetabling problem.

  5. Inferring local ecological processes amid species pool influences

    DEFF Research Database (Denmark)

    Lessard, Jean-Philippe; Belmaker, Jonathan; Myers, Jonathan A.

    2012-01-01

    studies, null models of community structure, and ecologically explicit definitions of the species pool as a means to compare predominant ecological processes among regions. By uniting concepts and tools from community ecology and macroecology, this approach might facilitate synthesis and resolve many......Resolving contingencies in community ecology requires comparative studies of local communities along broad-scale environmental gradients and in different biogeographic regions. However, comparisons of local ecological processes among regions require a synthetic understanding of how the species pool...... of potential community members influences the structure of ecological communities. Here, we outline an integrative approach for quantifying local ecological processes while explicitly accounting for species pool influences. Specifically, we highlight the utility of combining geographically replicated local...

  6. The filtering of raw water with partition system in pool row water for the process

    International Nuclear Information System (INIS)

    Harahap, Sentot Alibasya; Djunaidi

    2003-01-01

    The purpose of filtering raw water in the pool is decreasing soluble dirty in the water from Puspiptek PAM also the dirty from the environments. The monitoring of raw water since 1998 that the raw water is not so good in the quality. This partition system use tree type of screen a.i. the opened 10 mm, Mesh 60 and Mesh 100. The down position use a plat with 400 mm higher from the floor of the pool that given support frame from the L profile and strip plate by stainless steel (SS-304), use for deposited the impurities. The filter capability from the monitoring that the filtering result is a good quality, the TDS drop (Total Dissolved Solvent) is 2,5 gram/liter and the water filtering static type is (4 - 8,5) gram/liter

  7. Optimum allocation of imaging time and minimum detectable activity in dual isotope blood pool subtraction indium-111 platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Horowitz, S.F.; Goldsmith, S.J.; Fuster, V.

    1984-01-01

    Indium-111 labeled platelet imaging is a tool for detection of thrombus formation in vascular spaces. Dual isotope blood pool subtraction may help differentiate focal platelet accumulation from blood pool activity. This study used a computer model to calculate the minimum excess-to-blood pool platelet ratio (EX/BP) and the optimum dual isotope imaging times under varied conditions of lesion size. The model simulated usual human imaging doses of 500 μCi of In-111 platelets and 5mCi of Tc-99m labeled RBCs giving a reference cardiac blood pool region (100cc) of 10000 cpm for Tc-99m and 500 cpm for In-111. The total imaging time was fixed at 20 minutes, while the two isotope imaging times (TIn/TTc) were varied, as were the simulated lesion size (cc) and EX/BP. The relative error of the excess counts was calculated using propagation of error theory. At the critical level of detection, where the excess lesion counts equal 3 times the standard deviation, the optimum TIn/TTc and minimum Ex/BP were determined for each lesion size. For the smallest lesion size (0.1cc), the minimum detectable EX/BP ratio was 1.6, with the best TIn/TTC ratio of 18/2 minutes, and for large lesions, an EX/BP of 0.1, with a TIn/TTc of 16/4. This model provides an estimate of the sensitivity and optimizes imaging times in dual isotope subtraction platelet imaging. The model is adaptable to varying isotope doses, total imaging times and lesion size. This information will be helpful in future in- vivo imaging studies of intravascular thrombi in humans

  8. Alcoholism Detection by Data Augmentation and Convolutional Neural Network with Stochastic Pooling.

    Science.gov (United States)

    Wang, Shui-Hua; Lv, Yi-Ding; Sui, Yuxiu; Liu, Shuai; Wang, Su-Jing; Zhang, Yu-Dong

    2017-11-17

    Alcohol use disorder (AUD) is an important brain disease. It alters the brain structure. Recently, scholars tend to use computer vision based techniques to detect AUD. We collected 235 subjects, 114 alcoholic and 121 non-alcoholic. Among the 235 image, 100 images were used as training set, and data augmentation method was used. The rest 135 images were used as test set. Further, we chose the latest powerful technique-convolutional neural network (CNN) based on convolutional layer, rectified linear unit layer, pooling layer, fully connected layer, and softmax layer. We also compared three different pooling techniques: max pooling, average pooling, and stochastic pooling. The results showed that our method achieved a sensitivity of 96.88%, a specificity of 97.18%, and an accuracy of 97.04%. Our method was better than three state-of-the-art approaches. Besides, stochastic pooling performed better than other max pooling and average pooling. We validated CNN with five convolution layers and two fully connected layers performed the best. The GPU yielded a 149× acceleration in training and a 166× acceleration in test, compared to CPU.

  9. Is energy pooling necessary in ultraviolet matrix-assisted laser desorption/ionization?

    Science.gov (United States)

    Lin, Hou-Yu; Song, Botao; Lu, I-Chung; Hsu, Kuo-Tung; Liao, Chih-Yu; Lee, Yin-Yu; Tseng, Chien-Ming; Lee, Yuan-Tseh; Ni, Chi-Kung

    2014-01-15

    Energy pooling has been suggested as the key process for generating the primary ions during ultraviolet matrix-assisted laser desorption/ionization (UV-MALDI). In previous studies, decreases in fluorescence quantum yields as laser fluence increased for 2-aminobenzoic acid, 2,5-dihydroxybenzoic acid (2,5-DHB), and 3-hydroxypicolinic acid were used as evidence of energy pooling. This work extends the research to other matrices and addresses whether energy pooling is a universal property in UV-MALDI. Energy pooling was investigated in a time-resolved fluorescence experiment by using a short laser pulse (355 nm, 20 ps pulse width) for excitation and a streak camera (1 ps time resolution) for fluorescence detection. The excited-state lifetime of 2,5-DHB decreased with increases in laser fluence. This suggests that a reaction occurs between two excited molecules, and that energy pooling may be one of the possible reactions. However, the excited-state lifetime of 2,4,6-trihydroxyacetophenone (THAP) did not change with increases in laser fluence. The upper limit of the energy pooling rate constant for THAP is estimated to be approximately 100-500 times smaller than that of 2,5-DHB. The small energy pooling rate constant for THAP indicates that the potential contribution of the energy pooling mechanism to the generation of THAP matrix primary ions should be reconsidered. Copyright © 2013 John Wiley & Sons, Ltd.

  10. ENERGY STAR Certified Pool Pumps

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.1 ENERGY STAR Program Requirements for Pool Pumps that are effective as of February 15,...

  11. Conception of a sub aquatic lighting system for nuclear fuels storage pools

    International Nuclear Information System (INIS)

    Bracco, P.; Rosenthal, E.

    1990-01-01

    Restrictions like contaminated water, irradiated fuel elements in racks located on the bottom of the pool and the impossibility of removing the water, require a non conventional design of pool lamps. The model developed is independent of the pool, permitting easily fabrication and maintenance. They are made of stainless steel tubes with borosilicate windows, where floodlight or light are located. The lamp assembly is fixed at the border of the pool. The system offers advantages over the conventional pool lighting systems in fabrication, operation and maintenance. (author)

  12. Strategies for chemically healthy public swimming pools

    DEFF Research Database (Denmark)

    Hansen, Kamilla Marie Speht

    spreading of pathogens between swimmers because of its residual disinfection effect. In addition to potential contamination of pathogenic microorganisms, swimming pool water is polluted by organic matter deposited from the bathers such as saliva, urine, sweat, hair and personal care products. Since chlorine...... is a strong oxidant it oxidizes the organic matter in the pool water and forms disinfection byproducts (DBPs). More than 100 different DBPs have been identified. Some of these have been found to be genotoxic and may pose an increased cancer risk for the bathers. The aim of this thesis was to give an overview...... of the strategies which can be used to achieve microbiological safe water with low levels of DBPs to ensure healthy environment for bathers. There are different approaches to achieve healthy environment in public swimming pools which in this thesis are divided into three strategies: alternatives to chlorination...

  13. Corium quench in deep pool mixing experiments

    International Nuclear Information System (INIS)

    Spencer, B.W.; McUmber, L.; Gregorash, D.; Aeschlimann, R.; Sienicki, J.J.

    1985-01-01

    The results of two recent corium-water thermal interaction (CWTI) tests are described in which a stream of molten corium was poured into a deep pool of water in order to determine the mixing behavior, the corium-to-water heat transfer rates, and the characteristic sizes of the quenched debris. The corium composition was 60% UO 2 , 16% ZrO 2 , and 24% stainless steel by weight; its initial temperature was 3080 K, approx.160 K above the oxide phase liquidus temperature. The corium pour stream was a single-phase 2.2 cm dia liquid column which entered the water pool in film boiling at approx.4 m/s. The water subcooling was 6 and 75C in the two tests. Test results showed that with low subcooling, rapid steam generation caused the pool to boil up into a high void fraction regime. In contrast, with large subcooling no net steam generation occurred, and the pool remained relatively quiescent. Breakup of the jet appeared to occur by surface stripping. In neither test was the breakup complete during transit through the 32 cm deep water pool, and molten corium channeled to the base where it formed a melt layer. The characteristic heat transfer rates measured 3.5 MJ/s and 2.7 MJ/s during the fall stage for small and large subcooling, respectively; during the initial stage of bed quench, the surface heat fluxes measured 2.4 MW/m 2 and 3.7 MW/m 2 , respectively. A small mass of particles was formed in each test, measuring typically 0.1 to 1 mm and 1 to 5 mm dia for the large and small subcooling conditions, respectively. 9 refs., 13 figs., 1 tab

  14. Comparing survival outcomes of gross total resection and subtotal resection with radiotherapy for craniopharyngioma: a meta-analysis.

    Science.gov (United States)

    Wang, Guoqing; Zhang, Xiaoyang; Feng, Mengzhao; Guo, Fuyou

    2018-06-01

    Recent studies suggest that subtotal resection (STR) followed by radiation therapy (RT) is an appealing alternative to gross total resection (GTR) for craniopharyngioma, but it remains controversial. We conducted a meta-analysis to determine whether GTR is superior to STR with RT for craniopharyngioma. A systematic search was performed for articles published until October 2017 in the PubMed, Embase, and Cochrane Central databases. The endpoints of interest are overall survival and progression-free survival. Pooled hazard ratios (HRs) and corresponding 95% confidence intervals (CIs) were calculated using a fixed or random-effects model. The data were analyzed using Review Manager 5.3 software. A total of 744 patients (seven cohort studies) were enrolled for analyses. There were no significant differences between the GTR and STR with RT groups when the authors compared the pooled HRs at the end of the follow-up period. Overall survival (pooled HR = 0.76, 95% CI: 0.46-1.25, P = 0.28) and progression-free survival (pooled HR = 1.52, 95% CI: 0.42-5.44, P = 0.52) were similar between the two groups. The current meta-analysis suggests that GTR and STR with RT have the similar survival outcomes for craniopharyngioma. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Liquid sodium pool fires

    Energy Technology Data Exchange (ETDEWEB)

    Casselman, C [DSN/SESTR, Centre de Cadarache, Saint-Paul-lez-Durance (France)

    1979-03-01

    Experimental sodium pool combustion results have led to a definition of the combustion kinetics, and have revealed the hazards of sodium-concrete contact reactions and the possible ignition of organic matter (paint) by hydration of sodium peroxide aerosols. Analysis of these test results shows that the controlling mechanism is sodium evaporation diffusion. (author)

  16. Liquid sodium pool fires

    International Nuclear Information System (INIS)

    Casselman, C.

    1979-01-01

    Experimental sodium pool combustion results have led to a definition of the combustion kinetics, and have revealed the hazards of sodium-concrete contact reactions and the possible ignition of organic matter (paint) by hydration of sodium peroxide aerosols. Analysis of these test results shows that the controlling mechanism is sodium evaporation diffusion. (author)

  17. Clinical results with the Resolute zotarolimus-eluting stent in total coronary occlusions

    DEFF Research Database (Denmark)

    Kelbæk, Henning; Holmvang, Lene; Richardt, Gert

    2015-01-01

    Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods and resu......Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods...... lesion revascularisation) and Academic Research Consortium definite or probable stent thrombosis. The rate of TLF at two years was not significantly different among patients in the CTO (9.1%), TO (9.8%), and no occlusion (10.4%) groups (log-rank p=0.800); neither were the components of TLF. Definite...... or probable stent thrombosis occurred more frequently in the TO group (2.8% vs. 1.2% in the CTO and 1.1% in the group with no occlusion, p=0.027). There were 10 late and six very late stent thrombosis events. Conclusions: Apart from a higher rate of stent thrombosis in patients with TO, patients with totally...

  18. Comparison of individual and pooled stool samples for the assessment of intensity of Schistosoma mansoni and soil-transmitted helminth infections using the Kato-Katz technique.

    Science.gov (United States)

    Kure, Ashenafi; Mekonnen, Zeleke; Dana, Daniel; Bajiro, Mitiku; Ayana, Mio; Vercruysse, Jozef; Levecke, Bruno

    2015-09-24

    Our group has recently provided a proof-of-principle for the examination of pooled stool samples using McMaster technique as a strategy for the rapid assessment of intensity of soil-transmitted helminth infections (STH, Ascaris lumbricoides, Trichuris trichiura and hookworm). In the present study we evaluated this pooling strategy for the assessment of intensity of both STH and Schistosoma mansoni infections using the Kato-Katz technique. A cross-sectional survey was conducted in 360 children aged 5-18 years from six schools in Jimma Zone (southwest Ethiopia). We performed faecal egg counts (FECs) in both individual and pooled samples (pools sizes of 5, 10 and 20) to estimate the number of eggs per gram of stool (EPG) using the Kato-Katz technique. We also assessed the time to screen both individual and pooled samples. Except for hookworms, there was a significant correlation (correlation coefficient = 0.53-0.95) between the mean of individual FECs and the FECs of pooled samples for A. lumbricoides, T. trichiura and S. mansoni, regardless of the pool size. Mean FEC were 2,596 EPG, 125 EPG, 47 EPG, and 41 EPG for A. lumbricoides, T. trichiura, S. mansoni and hookworm, respectively. There was no significant difference in FECs between the examination of individual and pooled stool samples, except for hookworms. For this STH, pools of 10 resulted in a significant underestimation of infection intensity. The total time to obtain individual FECs was 65 h 5 min. For pooled FECs, this was 19 h 12 min for pools of 5, 14 h 39 min for pools of 10 and 12 h 42 min for pools of 20. The results indicate that pooling of stool sample holds also promise as a rapid assessment of infections intensity for STH and S. mansoni using the Kato-Katz technique. In this setting, the time in the laboratory was reduced by 70 % when pools of 5 instead of individual stool samples were screened.

  19. Hydrodynamics and heat transfer characteristics of liquid pools with bubble agitation

    International Nuclear Information System (INIS)

    Blottner, F.G.

    1979-11-01

    Estimates are given for the heat transfer coefficients at various interfaces which occur in molten pools on concrete. Previous simulant experiments and correlations are used to determine the hydrodynamic behavior of the pool and heat transfer coefficients for the liquids of interest. Other studies assume a gas film occurs between the concrete and molten pool, but the results of this investigation do not confirm this assumption. The results also indicate the significant influence the very viscous concrete slag has on the properties of the molten pool. Additional experiments and analysis are needed to improve the accuracy of the heat transfer coefficients estimated and to understand the behavior of the concrete slag at the interface between the pool and decomposing concrete

  20. Predicting the emissive power of hydrocarbon pool fires

    International Nuclear Information System (INIS)

    Munoz, Miguel; Planas, Eulalia; Ferrero, Fabio; Casal, Joaquim

    2007-01-01

    The emissive power (E) of a flame depends on the size of the fire and the type of fuel. In fact, it changes significantly over the flame surface: the zones of luminous flame have high emittance, while those covered by smoke have low E values. The emissive power of each zone (that is, the luminous or clear flame and the non-luminous or smoky flame) and the portion of total flame area they occupy must be assessed when a two-zone model is used. In this study, data obtained from an experimental set-up were used to estimate the emissive power of fires and its behaviour as a function of pool size. The experiments were performed using gasoline and diesel oil as fuel. Five concentric circular pools (1.5, 3, 4, 5 and 6 m in diameter) were used. Appropriate instruments were employed to determine the main features of the fires. By superimposing IR and VHS images it was possible to accurately identify the luminous and non-luminous zones of the fire. Mathematical expressions were obtained that give a more accurate prediction of E lum , E soot and the average emissive power of a fire as a function of its luminous and smoky zones. These expressions can be used in a two-zone model to obtain a better prediction of the thermal radiation. The value of the radiative fraction was determined from the thermal flux measured with radiometers. An expression is also proposed for estimating the radiative fraction

  1. Investigation to radioactive contamination of pool water in IMEF

    International Nuclear Information System (INIS)

    Song, Ung Sup; Jung, Yang Hong; Lee, J. H.; Lee, H. K.

    2003-06-01

    The pool (3x6x10) in irradiated materials examination facility is usually used for the purpose of taking the specimen out of cask loaded into the pool, and carrying in/out the specimen to/ from the hot cell. Always, it must be cared for the water into the pool to be fine condition because all operation are worked with the naked eye during taking an irradiated materials out of the cask and plunging them in the bucket-elevator. In the aspects of the radioactive remained substances in the water must be controlled so that the amount of substances to be lower than the standard amount prescribed by RCA Korea Activity in a part of radioactive contamination control. In consequence, an expertness of status and a practical use of skill make possible the prevention of radioactive material's diffusion or the radioactive contamination of pool water and safety work

  2. CAREM 25: Suppression pool cooling and purification system

    International Nuclear Information System (INIS)

    Carlevaris, Rodolfo; Patrignani, Alberto; Vindrola, Carlos; Palmerio, Hector D.; Quiroz, Horacio; Ramilo, Lucia B.

    2000-01-01

    The suppression pool cooling and purification system has the following main functions: purify and cool water from the suppression pool, cool and send water to the residual heat extraction system, and transfer water to the fuel element transference channel. In case of Loss of Coolant Accident (LOCA), the system sends water from the suppression pool to the spray network, thus cooling and reducing pressure in the primary containment. The system has been designed in accordance with the requirements of the following standards: ANSI/ANS 52.1; ANSI/ANS 57.2; ANSI/ANS 56.2; ANSI/ANS 59.1; ANSI/ANS 58.3; ANSI/ANS 58.9; and ANSI/ANS 56.5. The design of the system fulfils all the assigned functions. (author)

  3. Effect of donepezil on cognition in severe Alzheimer's disease: a pooled data analysis

    DEFF Research Database (Denmark)

    Cummings, Jeffrey; Jones, Roy; Wilkinson, David

    2010-01-01

    To better characterize response to donepezil in patients with severe AD, Severe Impairment Battery (SIB) data were pooled from four donepezil clinical trials (N=904). Changes in SIB total and domain scores from baseline to week 24 were compared between placebo and donepezil treatment groups...... between donepezil- and placebo-treated patients in least squares (LS) mean change in SIB total scores from baseline to week 24 was 6.22 (p Treatment-placebo differences were statistically significant for each baseline severity stratum, being greatest for the MMSE 6-9 stratum (LS...... mean difference, 7.60; p Treatment-placebo differences in LS mean change in SIB domain scores significantly favored donepezil for seven of nine domains (range, p = 0.0056 to p

  4. Topography Battles Surface Texture: An Experimental Study of Pool-riffle Formation

    Science.gov (United States)

    Chartrand, S. M.; Hassan, M. A.; Jellinek, M.

    2016-12-01

    Pool-riffles are perhaps the most common streambed shape found in streams and rivers, and not surprisingly, they are essential to salmon ecology, and are a central focus of many restoration actions. Yet, when an applied earth scientist or engineer is faced with developing a pool-riffle design, there is a lack of clear and rigorously developed design guidelines. Given the volumes of money spent annually within the restoration industry, this is a real problem. Recognition of this problem is growing, however, and an increasing level of attention has been directed to questions of pool-riffle formation in the past decade. At this point and given certain landscape characteristics, it is well established that streamwise gradients in channel width are associated with pool-riffles. Specifically, pools are associated with negative gradients in width, and riffles with positive gradients. Importantly, these associations have now been documented from field-derived data, as well as via experimental and numerical investigations. There is much to build from the present knowledge base, and central to this are questions related to (a) how pool-riffles evolve during the formative process, (b) what are the basic set of ingredients necessary for pool-riffle formation within systems characterized by relatively non-erodible channel margins, and (c) do pool-riffles persist, once formed, under a broad range of forcing conditions? We have completed four physical experiments examining the process and evolution of pool-riffle formation under a large range of upstream boundary, as well as physical channel conditions. We will report on two of the completed experiments. Our work will highlight two new non-dimensional channel evolution numbers, derived to help describe and characterize bedform development, as well as response to perturbations from near-equilibrium conditions. The channel evolution numbers lay the foundation for development of a new regime diagram, which quantifies the basic

  5. Laboratory investigation and simulation of breakthrough curves in karst conduits with pools

    Science.gov (United States)

    Zhao, Xiaoer; Chang, Yong; Wu, Jichun; Peng, Fu

    2017-12-01

    A series of laboratory experiments are performed under various hydrological conditions to analyze the effect of pools in pipes on breakthrough curves (BTCs). The BTCs are generated after instantaneous injections of NaCl tracer solution. In order to test the feasibility of reproducing the BTCs and obtain transport parameters, three modeling approaches have been applied: the equilibrium model, the linear graphical method and the two-region nonequilibrium model. The investigation results show that pools induce tailing of the BTCs, and the shapes of BTCs depend on pool geometries and hydrological conditions. The simulations reveal that the two-region nonequilibrium model yields the best fits to experimental BTCs because the model can describe the transient storage in pools by the partition coefficient and the mass transfer coefficient. The model parameters indicate that pools produce high dispersion. The increased tailing occurs mainly because the partition coefficient decreases, as the number of pools increases. When comparing the tracer BTCs obtained using the two types of pools with the same size, the more appreciable BTC tails that occur for symmetrical pools likely result mainly from the less intense exchange between the water in the pools and the water in the pipe, because the partition coefficients for the two types of pools are virtually identical. Dispersivity values decrease as flow rates increase; however, the trend in dispersion is not clear. The reduced tailing is attributed to a decrease in immobile water with increasing flow rate. It provides evidence for hydrodynamically controlled tailing effects.

  6. Thermal analysis and modeling of a swimming pool heating system by utilizing waste energy rejected from a chiller unit of an ice rink

    Directory of Open Access Journals (Sweden)

    Kuyumcu Muhammed Enes

    2017-01-01

    Full Text Available This study deals with the thermal analysis and modeling of a swimming pool heating system in which the waste energy rejected from the chiller unit of an ice rink is used as an energy source. The system consists of a swimming pool and an ice rink coupled by a chiller unit. The swimming pool and the ice rink both indoor types and were constructed in city of Gaziantep, Turkey. The thermal energy requirement for each section is determined by thermal analysis of each component of the system. Effects of different design parameters such as ceiling insulation thickness, ceiling emissivity, Carnot efficiency factor and size of the ice rink on the thermal energy requirements and coefficient of performance of the chiller unit are investigated. As a result of analyses of the system, the minimum ice rink area is determined in order to meet annual total heat energy demand of the olympic-sized swimming pool.

  7. Debris and pool formation/heat transfer in FARO-LWR: experiments and analyses

    International Nuclear Information System (INIS)

    Magallon, D.; Annunziato, A.; Corradini, M.

    1999-01-01

    The FARO-LWR experiments examine the debris and pool formation from a pour of core melt materials (UO 2 /ZrO 2 and UO 2 /ZrO 2 /Zr) into a pool of water at prototypic accident conditions. The experiments give unique data on the debris bed initial conditions, morphology and heat transfer after the core melt has slump and (partly) quenched into the water of the lower head. Quantities of up to 170 kg of corium melt are poured by gravity into water of depth between 1 and 2 m through a nozzle of diameter 0.1 m at different system pressures. The debris is collected in a flat bottom catcher of diameter 0.66 m. It reaches heights up to 0.2 m depending on the melt quantity. In general, the melt reaches the bottom only partially fragmented. The debris which forms consists of a conglomerate ('cake') in contact with the collecting structure and overlaying fragments (loose debris). The mean particle size of the loose debris is in the range 3.5 - 4.8 mm. The upper surface of the debris is flat. A gap is present between the cake and the bottom plate. The paper reviews the debris formation and heat transfer to the bottom steel structure from these tests and describes the development of a model to predict the debris and pool formation process. Sensitivity analyses have been performed by the COMETA code to study the behaviour of the ratio between the cake mass and the total mass. (authors)

  8. 17 CFR 275.206(4)-8 - Pooled investment vehicles.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Pooled investment vehicles... COMMISSION (CONTINUED) RULES AND REGULATIONS, INVESTMENT ADVISERS ACT OF 1940 § 275.206(4)-8 Pooled investment vehicles. (a) Prohibition. It shall constitute a fraudulent, deceptive, or manipulative act...

  9. Anticipated corrosion in the Vermont Yankee spent fuel pool

    International Nuclear Information System (INIS)

    Weeks, J.R.

    1977-06-01

    The report provides additional information relating to a proposed modification to the spent fuel pool at the Vermont Yankee Nuclear Power Station (VYNPS) and addresses corrosion of spent fuel pool storage materials and zircaloy, and provides an analysis of the effectiveness of the Boral sealing

  10. A Mechanistic Model of Waterfall Plunge Pool Erosion into Bedrock

    Science.gov (United States)

    Scheingross, Joel S.; Lamb, Michael P.

    2017-11-01

    Landscapes often respond to changes in climate and tectonics through the formation and upstream propagation of knickzones composed of waterfalls. Little work has been done on the mechanics of waterfall erosion, and instead most landscape-scale models neglect waterfalls or use rules for river erosion, such as stream power, that may not be applicable to waterfalls. Here we develop a physically based model to predict waterfall plunge pool erosion into rock by abrasion from particle impacts and test the model against flume experiments. Both the model and experiments show that evolving plunge pools have initially high vertical erosion rates due to energetic particle impacts, and erosion slows and eventually ceases as pools deepen and deposition protects the pool floor from further erosion. Lateral erosion can continue after deposition on the pool floor, but it occurs at slow rates that become negligible as pools widen. Our work points to the importance of vertical drilling of successive plunge pools to drive upstream knickzone propagation in homogenous rock, rather than the classic mechanism of headwall undercutting. For a series of vertically drilling waterfalls, we find that upstream knickzone propagation is faster under higher combined water and sediment fluxes and for knickzones composed of many waterfalls that are closely spaced. Our model differs significantly from stream-power-based erosion rules in that steeper knickzones can retreat faster or more slowly depending on the number and spacing of waterfalls within a knickzone, which has implications for interpreting climatic and tectonic history through analysis of river longitudinal profiles.

  11. Mitochondrial deoxyribonucleoside triphosphate pools in thymidine kinase 2 deficiency.

    Science.gov (United States)

    Saada, Ann; Ben-Shalom, Efrat; Zyslin, Rivka; Miller, Chaya; Mandel, Hanna; Elpeleg, Orly

    2003-10-24

    Deficiency of mitochondrial thymidine kinase (TK2) is associated with mitochondrial DNA (mtDNA) depletion and manifests by severe skeletal myopathy in infancy. In order to elucidate the pathophysiology of this condition, mitochondrial deoxyribonucleoside triphosphate (dNTP) pools were determined in patients' fibroblasts. Despite normal mtDNA content and cytochrome c oxidase (COX) activity, mitochondrial dNTP pools were imbalanced. Specifically, deoxythymidine triphosphate (dTTP) content was markedly decreased, resulting in reduced dTTP:deoxycytidine triphosphate ratio. These findings underline the importance of balanced mitochondrial dNTP pools for mtDNA synthesis and may serve as the basis for future therapeutic interventions.

  12. Core-concrete molten pool dynamics and interfacial heat transfer

    International Nuclear Information System (INIS)

    Benjamin, A.S.

    1980-01-01

    Theoretical models are derived for the heat transfer from molten oxide pools to an underlying concrete surface and from molten steel pools to a general concrete containment. To accomplish this, two separate effects models are first developed, one emphasizing the vigorous agitation of the molten pool by gases evolving from the concrete and the other considering the insulating effect of a slag layer produced by concrete melting. The resulting algebraic expressions, combined into a general core-concrete heat transfer representation, are shown to provide very good agreement with experiments involving molten steel pours into concrete crucibles

  13. Assessing the performance of multiplexed tandem PCR for the diagnosis of pathogenic genotypes of Theileria orientalis using pooled blood samples from cattle.

    Science.gov (United States)

    Gebrekidan, Hagos; Gasser, Robin B; Stevenson, Mark A; McGrath, Sean; Jabbar, Abdul

    2017-02-01

    Oriental theileriosis caused by multiple genotypes of Theileria orientalis is an important tick-borne disease of bovines. Here, we assessed the performance of an established multiplexed tandem PCR (MT-PCR) for the diagnosis of the two recognized, pathogenic genotypes (chitose and ikeda) of T. orientalis in cattle using pooled blood samples. We used a total of 265 cattle blood samples, which were divided into two groups according to previous MT-PCR results for individual samples. Samples in group 1 (n = 155) were from a herd with a relatively high prevalence of T. orientalis infection; and those in group 2 (n = 110) were from four herds with a low prevalence. For group 1, 31 and 15 batches of five- and ten-pooled samples (selected at random), respectively, were formed. For group 2, 22 and 11 batches of five- and ten-pooled samples (selected at random), respectively, were formed. DNAs from individual pooled samples in each batch and group were then tested by MT-PCR. For group 1, the apparent prevalences estimated using the 31 batches of five-pooled samples (97%) and 15 batches of ten-pooled samples (100%) were significantly higher compared with individual samples (75%). For group 2, higher apparent prevalences (9% and 36%) were also recorded for the 22 and 11 batches of pooled samples, respectively, compared with individual samples (7%). Overall, the average infection intensity recorded for the genotypes of chitose and ikeda were considerably lower in pooled compared with individual samples. The diagnostic specificities of MT-PCR were estimated at 95% and 94%, respectively, when batches of five- and ten-pooled samples were tested, and 94% for individual samples. The diagnostic sensitivity of this assay was estimated at 98% same for all individual, five- and ten-pooled samples. This study shows that screening batches of five- and ten-pooled blood samples from cattle herds are similar to those obtained for individual samples, and, importantly, that the reduced cost

  14. Assessment of a volume-dependent dynamic respiratory system compliance in ALI/ARDS by pooling breathing cycles

    International Nuclear Information System (INIS)

    Zhao, Zhanqi; Möller, Knut; Guttmann, Josef

    2012-01-01

    New methods were developed to calculate the volume-dependent dynamic respiratory system compliance (C rs ) in mechanically ventilated patients. Due to noise in respiratory signals and different characteristics of the methods, their results can considerably differ. The aim of the study was to establish a practical procedure to validate the estimation of intratidal dynamic C rs . A total of 28 patients from intensive care units of eight German university hospitals with acute lung injury (ALI) and acute respiratory distress syndrome (ARDS) were studied retrospectively. Dynamic volume-dependent C rs was determined during ongoing mechanical ventilation with the SLICE method, dynostatic algorithm and adaptive slice method. Conventional two-point compliance C 2P was calculated for comparison. A number of consecutive breathing cycles were pooled to reduce noise in the respiratory signals. C rs -volume curves produced with different methods converged when the number of pooling cycles increased (n ≥ 7). The mean volume-dependent C rs of 20 breaths was highly correlated with mean C 2P (C 2P,mean = 0.945 × C rs,mean − 0.053, r 2 = 0.968, p < 0.0001). The Bland–Altman analysis indicated that C 2P,mean was lower than C rs,mean (−2.4 ± 6.4 ml cm −1 H 2 O, mean bias ± 2 SD), but not significant according to the paired t-test (p > 0.05). Methods for analyzing dynamic respiratory mechanics are sensitive to noise and will converge to a unique solution when the number of pooled cycles increases. Under steady-state conditions, assessment of the volume-dependent C rs in ALI/ARDS patients can be validated by pooling respiratory data of consecutive breaths regardless of which method is applied. Confidence in dynamic C rs determination may be increased with the proposed pooling. (note)

  15. LCG Persistency Framework (POOL, CORAL, COOL) - Status and Outlook

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The LCG Persistency Framework consists of three software packages (POOL, CORAL and COOL) that address the data access requirements of the LHC experiments in several different areas. The project is the result of the collaboration between the CERN IT Department and the three experiments (ATLAS, CMS and LHCb) that are using some or all of the Persistency Framework components to access their data. The POOL package is a hybrid technology store for C++ objects, using a mixture of streaming and relational technologies to implement both object persistency and object metadata catalogs and collections. POOL provides generic components that can be used by the experiments to store both their event data and their conditions data. The CORAL package is an abstraction layer with an SQL-free API for accessing data stored using relational database technologies. It is used directly by experiment-specific applications and internally by both COOL and POOL. The COOL package provides specific software components and tools for the h...

  16. Amino acid synthesis in photosynthesizing spinach cells: effects of ammonia on pool sizes and rates of labeling from 14CO2

    International Nuclear Information System (INIS)

    Larsen, P.O.; Cornwell, K.L.; Gee, S.L.; Bassham, J.A.

    1981-01-01

    Isolated cells from leaves of Spinacia oleracea have been maintained in a state capable of high rates of photosynthetic CO 2 fixation for more than 60 hours. The incorporation of 14 CO 2 under saturating CO 2 conditions into carbohydrates, carboxylic acids, and amino acids, and the effect of ammonia on this incorporation have been studied. Total incorporation, specific radioactivity, and pool size have been determined as a function of time for most of the protein amino acids and for γ-aminobutyric acid. The measurements of specific radio-activities and of the approaches to 14 C saturation of some amino acids indicate the presence and relative sizes of metabolically active and passive pools of these amino acids. Added ammonia decreased carbon fixation into carbohydrates and increased fixation into carboxylic acids and amino acids. The results indicate that added ammonia stimulates the reactions mediated by pyruvate kinase and phosphenoenolpyruvate carboxylase, as seen with other plant systems. The data on the effects of added ammonia on total labeling, pool sizes, and specific radioactivities of several amino acids provides a number of indications about the intracellular sites of principal synthesis from carbon skeletons of these amino acids and the selective nature of effects of increased intracellular ammonia concentration on-such synthesis

  17. Study on Dynamic Development of Three-dimensional Weld Pool Surface in Stationary GTAW

    Science.gov (United States)

    Huang, Jiankang; He, Jing; He, Xiaoying; Shi, Yu; Fan, Ding

    2018-04-01

    The weld pool contains abundant information about the welding process. In particular, the type of the weld pool surface shape, i. e., convex or concave, is determined by the weld penetration. To detect it, an innovative laser-vision-based sensing method is employed to observe the weld pool surface of the gas tungsten arc welding (GTAW). A low-power laser dots pattern is projected onto the entire weld pool surface. Its reflection is intercepted by a screen and captured by a camera. Then the dynamic development process of the weld pool surface can be detected. By observing and analyzing, the change of the reflected laser dots reflection pattern, for shape of the weld pool surface shape, was found to closely correlate to the penetration of weld pool in the welding process. A mathematical model was proposed to correlate the incident ray, reflected ray, screen and surface of weld pool based on structured laser specular reflection. The dynamic variation of the weld pool surface and its corresponding dots laser pattern were simulated and analyzed. By combining the experimental data and the mathematical analysis, the results show that the pattern of the reflected laser dots pattern is closely correlated to the development of weld pool, such as the weld penetration. The concavity of the pool surface was found to increase rapidly after the surface shape was changed from convex to concave during the stationary GTAW process.

  18. Nitrogen fixation, denitrification, and ecosystem nitrogen pools in relation to vegetation development in the Subarctic

    DEFF Research Database (Denmark)

    Sørensen, Pernille Lærkedal; Jonasson, Sven Evert; Michelsen, Anders

    2006-01-01

    Nitrogen (N) fixation, denitrification, and ecosystem pools of nitrogen were measured in three subarctic ecosystem types differing in soil frost-heaving activity and vegetation cover. N2-fixation was measured by the acetylene reduction assay and converted to absolute N ecosystem input by estimates...... of conversion factors between acetylene reduction and 15N incorporation. One aim was to relate nitrogen fluxes and nitrogen pools to the mosaic of ecosystem types of different stability common in areas of soil frost movements. A second aim was to identify abiotic controls on N2-fixation by simultaneous...... measurements of temperature, light, and soil moisture. Nitrogen fixation rate was high with seasonal input estimated at 1.1 g N m2 on frostheaved sorted circles, which was higher than the total plant N content and exceeded estimated annual plant N uptake several-fold but was lower than the microbial N content...

  19. The burning and smoke release rates of sodium pool fires

    International Nuclear Information System (INIS)

    Newman, R.N.; Payne, J.F.B.

    1976-10-01

    The burning rates and smoke release fractions of sodium pool fires have been measured over the pool temperature range 250 0 C to 750 0 C. A theoretical model is derived which satisfactorily predicts the burning rate over the above temperature range. The theory further predicts that the burning rate should be independent of pool diameter, a prediction supported by a comparison of burning rate data from this study and available data from other studies. (author)

  20. Biophysical Interactions within Step-Pool Mountain Streams Following Wildfire

    Science.gov (United States)

    Parker, A.; Chin, A.; O'Dowd, A. P.

    2014-12-01

    Recovery of riverine ecosystems following disturbance is driven by a variety of interacting processes. Wildfires pose increasing disturbances to riverine landscapes, with rising frequencies and magnitudes owing to warming climates and increased fuel loads. The effects of wildfire include loss of vegetation, elevated runoff and flash floods, erosion and deposition, and changing biological habitats and communities. Understanding process interactions in post-fire landscapes is increasingly urgent for successful management and restoration of affected ecosystems. In steep channels, steps and pools provide prominent habitats for organisms and structural integrity in high energy environments. Step-pools are typically stable, responding to extreme events with recurrence intervals often exceeding 50 years. Once wildfire occurs, however, intensification of post-fire flood events can potentially overpower the inherent stability of these systems, with significant consequences for aquatic life and human well-being downstream. This study examined the short-term response of step-pool streams following the 2012 Waldo Canyon Fire in Colorado. We explored interacting feedbacks among geomorphology, hydrology, and ecology in the post-fire environment. At selected sites with varying burn severity, we established baseline conditions immediately after the fire with channel surveys, biological assessment using benthic macroinvertebrates, sediment analysis including pebble counts, and precipitation gauging. Repeat measurements after major storm events over several years enabled analysis of the interacting feedbacks among post-fire processes. We found that channels able to retain the step-pool structure changed less and facilitated recovery more readily. Step habitats maintained higher percentages of sensitive macroinvertebrate taxa compared to pools through post-fire floods. Sites burned with high severity experienced greater reduction in the percentage of sensitive taxa. The decimation of

  1. Total C and N Pools and fluxes vary with time, soil temperature, and moisture along an elevation, precipitation, and vegetation gradient in southern Appalachian Forests

    Science.gov (United States)

    Jennifer D. Knoepp; Craig R. See; James M. Vose; Chelcy F. Miniat; James S. Clark

    2018-01-01

    The interactions of terrestrial C pools and fluxes with spatial and temporal variation in climate are not well understood. We conducted this study in the southern Appalachian Mountains where complex topography provides variability in temperature, precipitation, and forest communities. In 1990, we established five large plots across an elevation gradient...

  2. Environmental burdens of a Finnish indoor swimming pool; Uimahallin ympaeristoekuormitukset

    Energy Technology Data Exchange (ETDEWEB)

    Vaahterus, T.; Saari, A.

    2001-07-01

    used the average information of the making of Finland's 1998 energy. The source information can vary according to the locality. The calculations were also sensitivity tested. The calculations of the environmental loads of the indoor swimming pool were most sensitive to changes in the hall usage. For example a two-degree (+/-) change in the water temperature of the indoor swimming halls pool changed the total amount of environmental emissions by 8 % (+/-). Other presumptions to which the calculations were relatively sensitive were the shell's thermal insulation capacity, capacity of the ventilation units and the condensate heat recovery. Changes in all these factors had at least a 2,5 % effect on the result of the calculations. (orig.)

  3. Research progresses and future directions on pool boiling heat transfer

    Directory of Open Access Journals (Sweden)

    M. Kumar

    2015-12-01

    Full Text Available This paper reviews the previous work carried on pool boiling heat transfer during heating of various liquids and commodities categorized as refrigerants and dielectric fluids, pure liquids, nanofluids, hydrocarbons and additive mixtures, as well as natural and synthetic colloidal solutions. Nucleate pool boiling is an efficient and effective method of boiling because high heat fluxes are possible with moderate temperature differences. It is characterized by the growth of bubbles on a heated surface. It occurs during boiling of liquids for excess temperature ranging from 5 to 30 °C in various processes related to high vaporization of liquid for specific purposes like sugarcane juice heating for jaggery making, milk heating for khoa making, steam generation, cooling of electronic equipments, refrigeration and etcetera. In this review paper, pool boiling method during heating of liquids for specific purpose is depicted. It is inferred that enhancement in pool boiling heat transfer is a challenging and complex task. Also, recent research and use of various correlations for natural convection pool boiling is reviewed.

  4. Burden of total and cause-specific mortality related to tobacco smoking among adults aged ≥ 45 years in Asia: a pooled analysis of 21 cohorts.

    Directory of Open Access Journals (Sweden)

    Wei Zheng

    2014-04-01

    Full Text Available Tobacco smoking is a major risk factor for many diseases. We sought to quantify the burden of tobacco-smoking-related deaths in Asia, in parts of which men's smoking prevalence is among the world's highest.We performed pooled analyses of data from 1,049,929 participants in 21 cohorts in Asia to quantify the risks of total and cause-specific mortality associated with tobacco smoking using adjusted hazard ratios and their 95% confidence intervals. We then estimated smoking-related deaths among adults aged ≥45 y in 2004 in Bangladesh, India, mainland China, Japan, Republic of Korea, Singapore, and Taiwan-accounting for ∼71% of Asia's total population. An approximately 1.44-fold (95% CI = 1.37-1.51 and 1.48-fold (1.38-1.58 elevated risk of death from any cause was found in male and female ever-smokers, respectively. In 2004, active tobacco smoking accounted for approximately 15.8% (95% CI = 14.3%-17.2% and 3.3% (2.6%-4.0% of deaths, respectively, in men and women aged ≥45 y in the seven countries/regions combined, with a total number of estimated deaths of ∼1,575,500 (95% CI = 1,398,000-1,744,700. Among men, approximately 11.4%, 30.5%, and 19.8% of deaths due to cardiovascular diseases, cancer, and respiratory diseases, respectively, were attributable to tobacco smoking. Corresponding proportions for East Asian women were 3.7%, 4.6%, and 1.7%, respectively. The strongest association with tobacco smoking was found for lung cancer: a 3- to 4-fold elevated risk, accounting for 60.5% and 16.7% of lung cancer deaths, respectively, in Asian men and East Asian women aged ≥45 y.Tobacco smoking is associated with a substantially elevated risk of mortality, accounting for approximately 2 million deaths in adults aged ≥45 y throughout Asia in 2004. It is likely that smoking-related deaths in Asia will continue to rise over the next few decades if no effective smoking control programs are implemented. Please see later in the article for

  5. Safety analysis of a pool Genesis II irradiator

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de A.

    2011-01-01

    The Genesis II Irradiator manufactured by GRAT * STAR Inc. (USA) is a category III gamma irradiator in which the sealed source is contained in a water filled storage pool and is shielded permanently, i.e. the material has to move down to the source. Even though the pool is 5.6 m deep, what would happen if the water level lowered? There are a series of safety devices that will avoid this situation and calculations show that the water level has to be very low in order to deliver a significant dose; moreover, only in case a person remains at the border of the pool for a long time this would be risky. In conclusion, it is practically impossible for someone to be exposed to radiation from a Genesis II Irradiator source. (author)

  6. CAREM-25. Suppression Pool Cooling and Purification System

    International Nuclear Information System (INIS)

    Carlevaris, Rodolfo; Palmerio, D.; Patrignani, A.; Quiroz, H.; Ramilo, L.; Vindrola, C.

    2000-01-01

    The Suppression Pool Cooling and Purification System has the following main functions: purify and cool water from the Suppression Pool, cool and send water to the Residual Heat Extraction System, and transfer water to the Fuel Element Transference Channel. In case of Loss of Coolant Accident (LOCA), the system sends water from the Suppression Pool to the spray network, thus cooling and reducing pressure in the primary containment.The system has been designed in accordance with the requirements of the following standards ANSI/ANS 52.1 [1], ANSI/ANS 57.2 [2], ANSI/ANS 56.2 [3], ANSI/ANS 59.1 [4] ANSI/ANS 58.3 [5], ANSI/ANS 58.9 [6], and ANSI/ANS 56.5 [7]. The design of the system fulfils all the assigned functions

  7. Pooled biological specimens for human biomonitoring of environmental chemicals: opportunities and limitations.

    Science.gov (United States)

    Heffernan, Amy L; Aylward, Lesa L; Toms, Leisa-Maree L; Sly, Peter D; Macleod, Matthew; Mueller, Jochen F

    2014-01-01

    Biomonitoring has become the "gold standard" in assessing chemical exposures, and has an important role in risk assessment. The pooling of biological specimens-combining multiple individual specimens into a single sample-can be used in biomonitoring studies to monitor levels of exposure and identify exposure trends or to identify susceptible populations in a cost-effective manner. Pooled samples provide an estimate of central tendency and may also reveal information about variation within the population. The development of a pooling strategy requires careful consideration of the type and number of samples collected, the number of pools required and the number of specimens to combine per pool in order to maximise the type and robustness of the data. Creative pooling strategies can be used to explore exposure-outcome associations, and extrapolation from other larger studies can be useful in identifying elevated exposures in specific individuals. The use of pooled specimens is advantageous as it saves significantly on analytical costs, may reduce the time and resources required for recruitment and, in certain circumstances, allows quantification of samples approaching the limit of detection. In addition, the use of pooled samples can provide population estimates while avoiding ethical difficulties that may be associated with reporting individual results.

  8. Phytomass carbon pool of trees and forests in India

    NARCIS (Netherlands)

    Kaul, M.; Mohren, G.M.J.; Dadhwal, V.K.

    2011-01-01

    The study reports estimates of above ground phytomass carbon pools in Indian forests for 1992 and 2002 using two different methodologies. The first estimate was derived from remote sensing based forest area and crown density estimates, and growing stock data for 1992 and 2002 and the estimated pool

  9. Swimming pools and shower rooms - sealing directly under the tiles avoids hygienically serious water accumulations. Schwimmbecken und Duschraeume - Abdichtung direkt unter den Fliesen vermeidet hygienisch bedenkliche Wasseransammlungen

    Energy Technology Data Exchange (ETDEWEB)

    Anon,

    1990-12-14

    Swimming pool seals are to carry out according to the DIN 18195 part 7 in which sealing with strips and foils is required; at the bottom of the pool a sufficiently dimensioned protective coating under the tiles and in the wall area using the following construction from the outside to the inside: tiles, mortar, face brickwork of at least half brick thickness and behind it a 4 cm shell joint. Then as the next layer follows the seal with foils or sealing strips. The total construction facing the water is thus with a total layer thickness of about 10 cm permanently exposed to water with all the thus resulting consequences. (orig.).

  10. Experimental characterization of the weld pool flow in a TIG configuration

    Science.gov (United States)

    Stadler, M.; Masquère, M.; Freton, P.; Franceries, X.; Gonzalez, J. J.

    2014-11-01

    Tungsten Inert Gas (TIG) welding process relies on heat transfer between plasma and work piece leading to a metallic weld pool. Combination of different forces produces movements on the molten pool surface. One of our aims is to determine the velocity on the weld pool surface. This provides a set of data that leads to a deeper comprehension of the flow behavior and allows us to validate numerical models used to study TIG parameters. In this paper, two diagnostic methods developed with high speed imaging for the determination of velocity of an AISI 304L stainless steel molten pool are presented. Application of the two methods to a metallic weld pool under helium with a current intensity of 100 A provides velocity values around 0.70 m/s which are in good agreement with literature works.

  11. Zooplankton at deep Red Sea brine pools

    KAUST Repository

    Kaartvedt, Stein

    2016-03-02

    The deep-sea anoxic brines of the Red Sea comprise unique, complex and extreme habitats. These environments are too harsh for metazoans, while the brine–seawater interface harbors dense microbial populations. We investigated the adjacent pelagic fauna at two brine pools using net tows, video records from a remotely operated vehicle and submerged echosounders. Waters just above the brine pool of Atlantis II Deep (2000 m depth) appeared depleted of macrofauna. In contrast, the fauna appeared to be enriched at the Kebrit Deep brine–seawater interface (1466 m).

  12. Use of Sugammadex in Patients With Obesity: A Pooled Analysis.

    Science.gov (United States)

    Monk, Terri G; Rietbergen, Henk; Woo, Tiffany; Fennema, Hein

    A growing proportion of patients undergoing surgical procedures are obese, providing anesthesiologists with numerous challenges for patient management. The current pooled analysis evaluated recovery times following sugammadex reversal of neuromuscular blockade by body mass index (BMI) in general, and in particular, in patients with BMIs ≥30 kg/m (defined as obese) and sugammadex doses for reversal of moderate [reappearance of the second twitch of the train-of-four (TOF); sugammadex 2 mg/kg] or deep (1-2 post-tetanic counts or 15 minutes after rocuronium; sugammadex 4 mg/kg) rocuronium- or vecuronium-induced neuromuscular blockade. All doses of sugammadex were administered based on actual body weight. The recovery time from sugammadex administration to a TOF ratio ≥0.9 was the primary efficacy variable in all individual studies and in the pooled analysis. This analysis comprised a total of 1418 adult patients treated with sugammadex; 267 (18.8%) of these patients had a BMI ≥30 kg/m. The average time to recovery of the TOF ratio to 0.9 was 1.9 minutes for rocuronium-induced blockade and 3.0 minutes for vecuronium-induced blockade. No clinically relevant correlation was observed between BMI and recovery time. The recommended sugammadex doses based on actual body weight provide rapid recovery from neuromuscular blockade in both obese and non-obese patients; no dose adjustments are required in the obese patient.

  13. The role of graphite foam pore structure on saturated pool boiling enhancement

    International Nuclear Information System (INIS)

    Pranoto, I.; Leong, K.C.; Jin, L.W.

    2012-01-01

    This paper presents an experimental study of the pool boiling phenomena and performance of porous graphite foam evaporators of different structures and thermophysical properties. Two dielectric liquids viz. FC-72 and HFE-7000 were used as working fluids. Block and fin evaporators of different fin-to-block-surface-area ratios (AR) were designed to study the role of the internal pore structure of graphite foams in a compact air-cooled thermosyphon under saturated pool boiling condition for high heat flux electronics cooling applications. The wall temperatures were measured and the boiling heat transfer coefficients were calculated to analyze the boiling performance. It was found that both fin structures with AR = 3.70 and 2.73 result in reduced boiling heat transfer performances and higher wall temperatures. The experimental results show that the boiling heat transfer coefficients of the block structures are about 1.2–1.6 times higher than those of the fin structures. The total internal surface area to volume ratio (β) and the total exposed areas (A T ) of the graphite foams were calculated in this study. The results show that the values of β and A T of the block structures are much higher than the fin structures for both tested “Pocofoam” 61% porosity and “Kfoam” 78% porosity evaporators which resulted in higher boiling heat transfer coefficient and lower wall temperature of the block structures. A visualization study shows that more bubbles were generated from the block structures compared to the fin structures due to the larger number of nucleation sites from the block structures. It was also found that use of FC-72 resulted in better boiling heat transfer performance compared to HFE-7000. - Highlights: ► We studied the pool boiling performance of a thermosyphon with graphite foam evaporators of block and fin structures. ► FC-72 and HFE-7000 were used as the working fluids. ► The boiling heat transfer coefficients of the block structures are 1.2

  14. High efficiency pool filtering systems utilising variable frequency drives

    Energy Technology Data Exchange (ETDEWEB)

    Hameiri, Z.; Sproul, A.B. [School of Photovoltaic and Renewable Energy Engineering, UNSW, Sydney, NSW 2052 (Australia); Spooner, T. [School of Electrical Engineering and Telecommunications, UNSW, Sydney, NSW 2052 (Australia)

    2009-02-15

    Over 1 year, private swimming pools in Australia will typically consume 1680 GWh of electricity, producing 2130 kt of CO{sub 2}. Redesigning a pool's filtration system and using it more efficiently can reduce the energy use, and hence the CO{sub 2} production, by a significant amount. This paper describes experimental measurements carried out on a new design of pool pump system. Initial experiments using a variable frequency drive (VFD) with a standard, single phase pump/motor system have achieved energy savings of 40%. Utilising a VFD and a three phase pump/motor energy savings of 61% have been achieved, without degrading the system performance. (author)

  15. Adequacy of patient pools to support predoctoral students' achievement of competence in pediatric dentistry in U.S. dental schools.

    Science.gov (United States)

    Casamassimo, Paul S; Seale, N Sue

    2015-06-01

    The aim of this study was to characterize the current status of predoctoral pediatric dentistry patient pools in U.S. dental schools and compare their status to that in 2001. A 2014 survey of school clinic-based and community-based dental patient pools was developed, piloted, and sent to pediatric predoctoral program directors in 57 U.S. dental schools via SurveyMonkey. Two follow-up contacts were made to increase the response rate. A total of 49 surveys were returned for a response rate of 86%. The responding program directors reported that their programs' patient pools had declined in number and had changed in character with more diversity and fewer procedures. They attributed the changes to competition, cost, and location of the dental school. The respondents reported that community-based dental education clinical sites continued to provide additional service experiences for dental students, with contributions varying by the nature of the site. A large number of the respondents felt that their graduates lacked some basic pediatric dentistry clinical skills and were not ready for independent practice with children. The results of this study suggest that the predoctoral pediatric dentistry patient pool has changed and general dentists may be graduating with inadequate experiences to practice dentistry for children.

  16. Cryptosporidium and Giardia in Swimming Pools, Atlanta, Georgia

    Centers for Disease Control (CDC) Podcasts

    In this podcast, Dan Rutz speaks with Dr. Joan Shields, a guest researcher with the Healthy Swimming Program at CDC, about an article in June 2008 issue of Emerging Infectious Diseases reporting on the results of a test of swimming pools in the greater Atlanta, Georgia area. Dr. Shields tested 160 pools in metro Atlanta last year for Cryptosporidium and Giardia. These germs cause most recreational water associated outbreaks.

  17. Mineral nutrition and alimentary pools in muskoxen and caribou on the Angujaartorfiup Nunaa range in West Greenland

    Directory of Open Access Journals (Sweden)

    Hans Staaland

    1999-04-01

    Full Text Available Minerals (Na, K, Cl, Ca, P, Mg and crude protein concentrations as well as total contents were measured throughout the alimentary tract of muskoxen and caribou from Angujaatorfiup Nunaa range, Søndre Strømfjord area in West Greenland. The muskoxen had significantly higher K concentrations in the caecum and proximal colon than the caribou. Caribou collected during the summer season had the highest Mg concentrations throughout the alimentary tract. In both species water, Na, K and CI concentrations decreased through the distal part of the alimentary system whereas Ca, Mg, P and crude protein concentrations increased. The muskoxen had relatively larger mineral pools and total content in the omasum than the caribou, and the caribou relatively larger mineral pools (except K and CI and total content in the caecum. Higher concentrations of Mg in the alimentary tract of the caribou than the muskoxen during the summer could also indicate that the caribou feed more on herbs with high concentrations of Mg. The data does also indicate that both the caribou and the muskoxen are living in an area where high intakes of minerals from both vegetation and mineral licks are possible. Based on the present study the muskoxen is apparently a typical grazer whereas the caribou is more like a concentrate selector.

  18. New set of convective heat transfer coefficients established for pools and validated against CLARA experiments for application to corium pools

    Energy Technology Data Exchange (ETDEWEB)

    Michel, B., E-mail: benedicte.michel@irsn.fr

    2015-05-15

    Highlights: • A new set of 2D convective heat transfer correlations is proposed. • It takes into account different horizontal and lateral superficial velocities. • It is based on previously established correlations. • It is validated against recent CLARA experiments. • It has to be implemented in a 0D MCCI (molten core concrete interaction) code. - Abstract: During an hypothetical Pressurized Water Reactor (PWR) or Boiling Water Reactor (BWR) severe accident with core meltdown and vessel failure, corium would fall directly on the concrete reactor pit basemat if no water is present. The high temperature of the corium pool maintained by the residual power would lead to the erosion of the concrete walls and basemat of this reactor pit. The thermal decomposition of concrete will lead to the release of a significant amount of gases that will modify the corium pool thermal hydraulics. In particular, it will affect heat transfers between the corium pool and the concrete which determine the reactor pit ablation kinetics. A new set of convective heat transfer coefficients in a pool with different lateral and horizontal superficial gas velocities is modeled and validated against the recent CLARA experimental program. 155 tests of this program, in two size configurations and a high range of investigated viscosity, have been used to validate the model. Then, a method to define different lateral and horizontal superficial gas velocities in a 0D code is proposed together with a discussion about the possible viscosity in the reactor case when the pool is semi-solid. This model is going to be implemented in the 0D ASTEC/MEDICIS code in order to determine the impact of the convective heat transfer in the concrete ablation by corium.

  19. Strong influence of regional species pools on continent-wide structuring of local communities

    DEFF Research Database (Denmark)

    Lessard, Jean-Philippe; Borregaard, Michael Krabbe; Fordyce, James A.

    2012-01-01

    pool, to examine the interplay between broad-scale evolutionary and fine-scale ecological processes. Finally, a renewed interest in the influence of species source pools on communities has shown that the definition of the source pool influences interpretations of patterns of community structure. We use...... of communities along climatic gradients. We find that the average phylogenetic relatedness of species in ant communities decreases from tropical to temperate regions, but the strength of this relationship depends on the level of ecological realism in the definition of source pools. We conclude that the evolution...... of climatic niches influences the phylogenetic structure of regional source pools and that the influence of regional source pools on local community structure is strong....

  20. Heat and fission product transport in molten core material pool with crust

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2005-01-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the reactor vessel during a severe accident. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool is estimated by product of the mass concentration and energy conversion factor of each fission product. Twenty-nine elements are chosen and classified by their chemical properties to calculate heat generation rate in the pool. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis is performed for heat and fission product transport in a molten core material pool during the Three Mile Island Unit 2 (TMI-2) accident. The pool is assumed to be a partially filled hemisphere, whose change in geometry is neglected during the numerical calculation. Calculated results indicate that the peak temperature in the molten pool is significantly lowered, since a substantial amount of the volatile fission products is released from the molten pool during progression of the accident. The results may directly be applied to the existing severe accident analysis codes to more mechanistically determine the thermal load to the reactor vessel lower head during the in-vessel retention

  1. Comparison of individual and pooled samples for quantification of antimicrobial resistance genes in swine feces by high-throughput qPCR

    DEFF Research Database (Denmark)

    Clasen, Julie; Mellerup, Anders; Olsen, J. E.

    2015-01-01

    There is a considerable societal interest in the careful monitoring of antimicrobial resistance (AMR) levels in human and animal populations. Sampling and data analysis can be both costly and time consuming. Optimization of sample pooling procedures is therefore important to reduce costs...... and analysis times. The objective of this study was to estimate how many individual fecal samples are needed to pool to get a representative sample for quantification of AMR-genes in a Danish pig herd. 20 individual fecal samples were collected from one section in a Danish pig herd. One to five rectal fecal...... samples were taken from each pen with respect to the number of pigs in the pen. A total of 48 pools were made of increasing number of individual samples. The levels of 9 different AMR-genes were quantified using dynamic qPCR arrays on the BioMark HD system(Fluidigm®).DNA was extracted using the Maxwell...

  2. A protocol for measuring spatial variables in soft-sediment tide pools

    Directory of Open Access Journals (Sweden)

    Marina R. Brenha-Nunes

    2016-01-01

    Full Text Available ABSTRACT We present a protocol for measuring spatial variables in large (>50 m2 soft-sediment tide pool. Secondarily, we present the fish capture efficiency of a sampling protocol that based on such spatial variables to calculate relative abundances. The area of the pool is estimated by summing areas of basic geometric forms; the depth, by taken representative measurements of the depth variability of each pool's sector, previously determined according to its perimeter; and the volume, by considering the pool as a prism. These procedures were a trade-off between the acquisition of reliable estimates and the minimization of both the cost of operating and the time spent in field. The fish sampling protocol is based on two con secutive stages: 1 two people search for fishes under structures (e.g., rocks and litters on the pool and capture them with hand seines; 2 these structures are removed and then a beach-seine is hauled over the whole pool. Our method is cheaper than others and fast to operate considering the time in low tides. The method to sample fish is quite efficient resulting in a capture efficiency of 89%.

  3. Afterlife of a Drop Impacting a Liquid Pool

    Science.gov (United States)

    Saha, Abhishek; Wei, Yanju; Tang, Xiaoyu; Law, Chung K.

    2017-11-01

    Drop impact on liquid pool is ubiquitous in industrial processes, such as inkjet printing and spray coating. While merging of drop with the impacted liquid surface is essential to facilitate the printing and coating processes, it is the afterlife of this merged drop and associated mixing which control the quality of the printed or coated surface. In this talk we will report an experimental study on the structural evolution of the merged droplet inside the liquid pool. First, we will analyze the depth of the crater created on the pool surface by the impacted drop for a range of impact inertia, and we will derive a scaling relation and the associated characteristic time-scale. Next, we will focus on the toroidal vortex formed by the moving drop inside the liquid pool and assess the characteristic time and length scales of the penetration process. The geometry of the vortex structure which qualitatively indicates the degree of mixedness will also be discussed. Finally, we will present the results from experiments with various viscosities to demonstrate the role of viscous dissipation on the geometry and structure formed by the drop. This work is supported by the Army Research Office and the Xerox Corporation.

  4. Role of the mitochondrial amino acid pool in the differential sensitivity of erythroid and myeloid cells to chloramphenicol

    International Nuclear Information System (INIS)

    Abou-Khalil, S.; Abou-Khalil, W.H.; Whitney, P.L.; Yunis, A.A.

    1986-01-01

    Previous studies in the authors laboratory have suggested that mitochondrial amino acid (AA) pool is involved in the differential sensitivity of erythroid and myeloid cells to chloramphenicol (CAP). The present study examines the role of AA pool by analysis of its composition and testing the effects of its major components. The endogenous AA composition of isolated mitochondria protein was determined using a JEOL 5AH AA analyzer. L-( 14 C) leucine incorporation into mitochondrial protein was used to measure the rate of protein synthesis. Analysis of the endogenous pool in erythroleukemia (EM) and chloroleukemia (CM) mitochrondria showed similar total amount of AAs. However, some AAs were present in significantly higher or lower quantity within EM and CM (i.e. EM had about 2-fold higher glycine content). When compensating for each low AA addition of that particular acid to the reaction medium, only glycine and serine had significant effect. Thus, the addition of increasing concentrations of glycine or serine enhanced the sensitivity to CAP from 14% to 49-51% in CM but not in EM. Other AAs gave little or no effect. Since glycine is one of the first reactants in heme biosynthesis within mitochondria and is interconvertible with serine, it would appear that erythroid cells sensitivity to CAP is determined by the mitochondrial glycine-serine pool and may be somehow related of the pathway to heme biosynthesis in these cells

  5. Crowd density estimation based on convolutional neural networks with mixed pooling

    Science.gov (United States)

    Zhang, Li; Zheng, Hong; Zhang, Ying; Zhang, Dongming

    2017-09-01

    Crowd density estimation is an important topic in the fields of machine learning and video surveillance. Existing methods do not provide satisfactory classification accuracy; moreover, they have difficulty in adapting to complex scenes. Therefore, we propose a method based on convolutional neural networks (CNNs). The proposed method improves performance of crowd density estimation in two key ways. First, we propose a feature pooling method named mixed pooling to regularize the CNNs. It replaces deterministic pooling operations with a parameter that, by studying the algorithm, could combine the conventional max pooling with average pooling methods. Second, we present a classification strategy, in which an image is divided into two cells and respectively categorized. The proposed approach was evaluated on three datasets: two ground truth image sequences and the University of California, San Diego, anomaly detection dataset. The results demonstrate that the proposed approach performs more effectively and easily than other methods.

  6. Strong influence of regional species pools on continent-wide structuring of local communities.

    Science.gov (United States)

    Lessard, Jean-Philippe; Borregaard, Michael K; Fordyce, James A; Rahbek, Carsten; Weiser, Michael D; Dunn, Robert R; Sanders, Nathan J

    2012-01-22

    There is a long tradition in ecology of evaluating the relative contribution of the regional species pool and local interactions on the structure of local communities. Similarly, a growing number of studies assess the phylogenetic structure of communities, relative to that in the regional species pool, to examine the interplay between broad-scale evolutionary and fine-scale ecological processes. Finally, a renewed interest in the influence of species source pools on communities has shown that the definition of the source pool influences interpretations of patterns of community structure. We use a continent-wide dataset of local ant communities and implement ecologically explicit source pool definitions to examine the relative importance of regional species pools and local interactions for shaping community structure. Then we assess which factors underlie systematic variation in the structure of communities along climatic gradients. We find that the average phylogenetic relatedness of species in ant communities decreases from tropical to temperate regions, but the strength of this relationship depends on the level of ecological realism in the definition of source pools. We conclude that the evolution of climatic niches influences the phylogenetic structure of regional source pools and that the influence of regional source pools on local community structure is strong.

  7. Gene pool conservation of teak in Myanmar

    International Nuclear Information System (INIS)

    Tin-Tun

    1995-01-01

    Myanmar with an area of 261, 228 Sq. miles is endowed with various types of forests which occupied nearly 50% of the country. Teak (Tectona grandis Linn. f.) is one of the most valuable timber species for its excellent wood quality and properties which are not observed with other timbers. Gene pool can be defined as a group of individual trees growing over a wide range of environmental conditions, and constituting different genetic complexes which can be transmitted to the offsprings. Topics such as: objectives of gene pool conservation, genetically improved seeds for large scale forest plantations, methodology of conservation, are discussed in the article. Myanmar teak dominates the world's teak market, and thus it is crucial to maintain the superiority in the conservation of gene complexes of teak. To some extent, the conservation of gene pools of teak and tree improvements are being undertaken by the Forest Research Institute of Myanmar. It is felt that the dissemination of the philosophy and concept of gene conservation to the personal involved in the forestry activities of the country are still inadequate

  8. Frozen gene pools - A future for species otherwise destined for extinction

    Science.gov (United States)

    Gee, G.F.

    1986-01-01

    Conclusion: Semen banks and ova and embryo banks can be practical methods to maintain gene pools. Gene pool preservation is desperately needed today due to the rapid decline in number of species and their habitat, a matter that is of concern to.biologists, economists, and politicians worldwide. Techniques are available for the cryopreservation of semen from many animals (and embryos from a few mammals) and adaptations of these techniques to other animals should be possible. A frozen gene pool in conjunction with existing programs makes it possible to preserve gene pools at less cost or in.some cases where no other alternative to extinction existed.

  9. Sculpting the Barnyard Gene Pool

    Science.gov (United States)

    Childers, Gina; Wolfe, Kim; Dupree, Alan; Young, Sheila; Caver, Jessica; Quintanilla, Ruby; Thornton, Laura

    2016-01-01

    Project-based learning (PBL) takes student engagement to a higher level through reflective collaboration, inquiry, critical thinking, problem solving, and personal relevance. This article explains how six high school teachers developed an interconnected, interdisciplinary STEM-focused PBL called "Sculpting the Barnyard Gene Pool." The…

  10. Assessment of air and water contamination by disinfection by-products at 41 indoor swimming pools.

    Science.gov (United States)

    Tardif, Robert; Catto, Cyril; Haddad, Sami; Simard, Sabrina; Rodriguez, Manuel

    2016-07-01

    This study was aimed at assessing the profiles (occurrence and speciation) of disinfection by-product (DBP) contamination in air and water of a group of 41 public indoor swimming pools in Québec (Canada). The contaminants measured in the water included the traditional DBPs [i.e., four trihalomethanes (THMs), six haloacetic acids (HAAs)] but also several emergent DBPs [i.e., halonitriles, halonitromethanes, haloketones and nitrosodimethylamine (NDMA)]. Those measured in the air comprised THMs and chloramines (CAMs). Overall, extremely variable DBP levels were found from one pool to another (both quantitatively and in terms of speciation). For instance, in water, among the four THMs, chloroform was usually the most abundant compound (37.9±25.7µg/L). Nevertheless, the sum of the three other brominated THMs represented more than 25% of total THMs at almost half the facilities visited (19 cases). In 13 of them, the levels of brominated THMs (66±24.2µg/L) even greatly outweighed the levels of chloroform (15.2±6.31µg/L). Much higher levels of HAAs (294.8±157.6µg/L) were observed, with a consistent preponderance of brominated HAAs in the swimming pools with more brominated THMs. NDMA levels which were measured in a subset of 8 pools ranged between 2.8ng/L and 105ng/L. With respect to air, chloroform was still the most abundant THM globally (119.4±74.2µg/m(3)) but significant levels of brominated THMs were also observed in various cases, particularly in the previously evoked group of 13 swimming pools with preponderant levels of brominated THMs in water. CAM levels (0.23±0.15mg/m(3)) varied highly, ranging from not detected to 0.56mg/m(3). Overall, the levels were generally relatively high compared to current guidelines or reference values from several countries, and they point to a relatively atypical presence of brominated compounds, and to significant levels of emergent DBPs for which health risk is less documented. Copyright © 2016 Elsevier Inc. All rights

  11. Citalopram and escitalopram in the treatment of major depressive disorder: a pooled analysis of 3 clinical trials.

    Science.gov (United States)

    Li, Huafang; Li, Ting; Li, Guanjun; Luo, Jianfeng

    2014-11-01

    Pooled analysis is a powerful technique that is increasingly used to detect differences in efficacy between pharmacologic agents. Some studies have compared the efficacy and tolerability of citalopram and escitalopram, with contradictory results. The aim of this study was to compare the efficacy and tolerability of citalopram and escitalopram in the treatment of major depressive disorder (MDD) using pooled analyses. Data from 3 randomized, double-blind studies that compared citalopram (20 to 40 mg/d) and escitalopram (10 to 20 mg/d) were pooled and analyzed. The primary efficacy parameter was change from baseline in the 17-item Hamilton Rating Scale for Depression (HAM-D-17) total score. Efficacy assessments were made at weeks 0 (baseline), 1, 2, 4, and 6. Based on the mean change from baseline in the HAM-D-17 at weeks 1, 2, 4, and 6, the efficacy of citalopram, 20 to 40 mg/d, was equivalent to escitalopram, 10 to 20 mg/d (P > .05). Similar results were seen for severely depressed patients, with a mean treatment difference of 13.9 (SE = 7.6) vs 15.9 (SE = 7.5). Response and remission rates at week 6 were similar (response, 72.4% for citalopram, compared with 73.5% for escitalopram; remission, 52.6% vs 54.5%, respectively). The pooled analysis showed that over a 6-week treatment period, citalopram, 20 to 40 mg/d, is equivalent to escitalopram, 10 to 20 mg/d, in both efficacy and tolerability.

  12. UPDG: Utilities package for data analysis of Pooled DNA GWAS

    Directory of Open Access Journals (Sweden)

    Ho Daniel WH

    2012-01-01

    Full Text Available Abstract Background Despite being a well-established strategy for cost reduction in disease gene mapping, pooled DNA association study is much less popular than the individual DNA approach. This situation is especially true for pooled DNA genomewide association study (GWAS, for which very few computer resources have been developed for its data analysis. This motivates the development of UPDG (Utilities package for data analysis of Pooled DNA GWAS. Results UPDG represents a generalized framework for data analysis of pooled DNA GWAS with the integration of Unix/Linux shell operations, Perl programs and R scripts. With the input of raw intensity data from GWAS, UPDG performs the following tasks in a stepwise manner: raw data manipulation, correction for allelic preferential amplification, normalization, nested analysis of variance for genetic association testing, and summarization of analysis results. Detailed instructions, procedures and commands are provided in the comprehensive user manual describing the whole process from preliminary preparation of software installation to final outcome acquisition. An example dataset (input files and sample output files is also included in the package so that users can easily familiarize themselves with the data file formats, working procedures and expected output. Therefore, UPDG is especially useful for users with some computer knowledge, but without a sophisticated programming background. Conclusions UPDG provides a free, simple and platform-independent one-stop service to scientists working on pooled DNA GWAS data analysis, but with less advanced programming knowledge. It is our vision and mission to reduce the hindrance for performing data analysis of pooled DNA GWAS through our contribution of UPDG. More importantly, we hope to promote the popularity of pooled DNA GWAS, which is a very useful research strategy.

  13. Magnetic resonance angiography with blood-pool contrast agents: future applications

    International Nuclear Information System (INIS)

    Fink, C.; Goyen, M.; Lotz, J.

    2007-01-01

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  14. Magnetic resonance angiography with blood-pool contrast agents: future applications

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Univ. Hospitals, Grosshadern, Munich (Germany); Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Lotz, J. [Hannover Medical School, Hannover (Germany)

    2007-03-15

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  15. Water inventory management in condenser pool of boiling water reactor

    International Nuclear Information System (INIS)

    Gluntz, D.M.

    1996-01-01

    An improved system for managing the water inventory in the condenser pool of a boiling water reactor has means for raising the level of the upper surface of the condenser pool water without adding water to the isolation pool. A tank filled with water is installed in a chamber of the condenser pool. The water-filled tank contains one or more holes or openings at its lowermost periphery and is connected via piping and a passive-type valve (e.g., squib valve) to a high-pressure gas-charged pneumatic tank of appropriate volume. The valve is normally closed, but can be opened at an appropriate time following a loss-of-coolant accident. When the valve opens, high-pressure gas inside the pneumatic tank is released to flow passively through the piping to pressurize the interior of the water-filled tank. In so doing, the initial water contents of the tank are expelled through the openings, causing the water level in the condenser pool to rise. This increases the volume of water available to be boiled off by heat conducted from the passive containment cooling heat exchangers. 4 figs

  16. Plasma non-esterified docosahexaenoic acid is the major pool supplying the brain.

    Science.gov (United States)

    Chen, Chuck T; Kitson, Alex P; Hopperton, Kathryn E; Domenichiello, Anthony F; Trépanier, Marc-Olivier; Lin, Lauren E; Ermini, Leonardo; Post, Martin; Thies, Frank; Bazinet, Richard P

    2015-10-29

    Despite being critical for normal brain function, the pools that supply docosahexaenoic acid (DHA) to the brain are not agreed upon. Using multiple kinetic models in free-living adult rats, we first demonstrate that DHA uptake from the plasma non-esterified fatty acid (NEFA) pool predicts brain uptake of DHA upon oral administration, which enters the plasma NEFA pool as well as multiple plasma esterified pools. The rate of DHA loss by the brain is similar to the uptake from the plasma NEFA pool. Furthermore, upon acute iv administration, although more radiolabeled lysophosphatidylcholine (LPC)-DHA enters the brain than NEFA-DHA, this is due to the longer plasma half-life and exposure to the brain. Direct comparison of the uptake rate of LPC-DHA and NEFA-DHA demonstrates that uptake of NEFA-DHA into the brain is 10-fold greater than LPC-DHA. In conclusion, plasma NEFA-DHA is the major plasma pool supplying the brain.

  17. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    Energy Technology Data Exchange (ETDEWEB)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V. (Mt. Sinai Medical Center, New York, NY (USA))

    1989-09-01

    Blood-pool subtraction has been proposed to enhance {sup 111}In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging.

  18. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V.

    1989-01-01

    Blood-pool subtraction has been proposed to enhance 111 In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging

  19. Environmental assessment, K Pool fish rearing, Hanford Site, Richland, Washington

    International Nuclear Information System (INIS)

    1996-12-01

    The US Department of Energy (DOE) has a need to respond to a request to lease facilities at the Hanford Site 100-KE and 100-KW filter plant pools (K Pools) for fish rearing activities. These fish rearing activities would be: (1) business ventures with public and private funds and (2) long-term enhancement and supplementation programs for game fish populations in the Columbia River Basin. The proposed action is to enter into a use permit or lease agreement with the YIN or other parties who would rear fish in the 100-K Area Pools. The proposed action would include necessary piping, pump, and electrical upgrades of the facility; cleaning and preparation of the pools; water withdrawal from the Columbia River, and any necessary water or wastewater treatment; and introduction, rearing and release of fish. Future commercial operations may be included

  20. Environmental assessment, K Pool fish rearing, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The US Department of Energy (DOE) has a need to respond to a request to lease facilities at the Hanford Site 100-KE and 100-KW filter plant pools (K Pools) for fish rearing activities. These fish rearing activities would be: (1) business ventures with public and private funds and (2) long-term enhancement and supplementation programs for game fish populations in the Columbia River Basin. The proposed action is to enter into a use permit or lease agreement with the YIN or other parties who would rear fish in the 100-K Area Pools. The proposed action would include necessary piping, pump, and electrical upgrades of the facility; cleaning and preparation of the pools; water withdrawal from the Columbia River, and any necessary water or wastewater treatment; and introduction, rearing and release of fish. Future commercial operations may be included.

  1. 76 FR 64085 - Post-2014 Resource Pool-Loveland Area Projects, Final Power Allocation

    Science.gov (United States)

    2011-10-17

    ... Resource Pool; Loveland Area Projects, General Eligibility Criteria. The resource pool for capacity and... transmission in Kansas. Final allocation of the Post-2014 Resource Pool; Loveland Area Projects, is contingent...

  2. Numerical simulation of pool boiling of a Lennard-Jones liquid

    KAUST Repository

    Inaoka, Hajime; Ito, Nobuyasu

    2013-01-01

    We performed a numerical simulation of pool boiling by a molecular dynamics model. In the simulation, a liquid composed of Lennard-Jones particles in a uniform gravitational field is heated by a heat source at the bottom of the system. The model successfully reproduces the change in regimes of boiling from nucleate boiling to film boiling with the increase of the heat source temperature. We present the pool boiling curve by the model, whose general behavior is consistent with those observed in experiments of pool boiling. © 2013 Elsevier B.V. All rights reserved.

  3. Numerical simulation of pool boiling of a Lennard-Jones liquid

    KAUST Repository

    Inaoka, Hajime

    2013-09-01

    We performed a numerical simulation of pool boiling by a molecular dynamics model. In the simulation, a liquid composed of Lennard-Jones particles in a uniform gravitational field is heated by a heat source at the bottom of the system. The model successfully reproduces the change in regimes of boiling from nucleate boiling to film boiling with the increase of the heat source temperature. We present the pool boiling curve by the model, whose general behavior is consistent with those observed in experiments of pool boiling. © 2013 Elsevier B.V. All rights reserved.

  4. One component, volume heated, boiling pool thermohydraulics

    International Nuclear Information System (INIS)

    Bede, M.; Perret, C.; Pretrel, H.; Seiler, J.M.

    1993-01-01

    Prior work on boiling pools provided heat exchange correlations valid for bubbly flow with laminar or turbulent boundary layers. New experiments performed with water (SEBULON) and UO 2 (SCARABEE BF2) in a churn-turbulent flow configuration show unexpected heat flux distributions for which the maximum heat flux may be situated well below the pool surface. The origin of this behaviour is attributed to condensation effects, very unstable boundary layer flow and surface oscillation. A calculation model is discussed which permits to approach the experimental heat flux distribution with reasonable accuracy. (authors). 7 figs., 2 appendix., 14 refs

  5. Volume-heated boiling pool behavior and application to transition phase accident conditions

    International Nuclear Information System (INIS)

    Ginsberg, T.; Jones, O.C. Jr.; Chen, J.C.

    1978-01-01

    Observations of two-phase flow fields in volume-heated boiling pools are reported. Photographic observations, together with pool-average void fraction measurements are presented. Flow regime transition criterial derived from the measurements are discussed. The churn-turbulent flow regime was the dominant regime for superficial vapor velocity. Within this range of conditions, a churn-turbulent drift flux model provides a reasonable prediction of the pool-average void fraction data. The results of the experiment and analysis are extrapolated to transition phase conditions. It is shown that intense pool boil-up could occur where the pool-average void fraction would be greater than 0.6 for steel vaporization rates equivalent to power levels greater than one percent of nominal LMFBR power density. (author)

  6. AUS burnup module CHAR and the associated data pool

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1975-12-01

    The CHAR module of the AUS reactor neutronics scheme solves the multiregion nuclide depletion equations using an analytic method. The module obtains cross section, flux and geometry data from AUS data pools, and uses the STATUS data pool which has been designed for the storage of nuclide compositions, spatial smearing factors and other miscellaneous information. (author)

  7. Inter-progenitor pool wiring: An evolutionarily conserved strategy that expands neural circuit diversity.

    Science.gov (United States)

    Suzuki, Takumi; Sato, Makoto

    2017-11-15

    Diversification of neuronal types is key to establishing functional variations in neural circuits. The first critical step to generate neuronal diversity is to organize the compartmental domains of developing brains into spatially distinct neural progenitor pools. Neural progenitors in each pool then generate a unique set of diverse neurons through specific spatiotemporal specification processes. In this review article, we focus on an additional mechanism, 'inter-progenitor pool wiring', that further expands the diversity of neural circuits. After diverse types of neurons are generated in one progenitor pool, a fraction of these neurons start migrating toward a remote brain region containing neurons that originate from another progenitor pool. Finally, neurons of different origins are intermingled and eventually form complex but precise neural circuits. The developing cerebral cortex of mammalian brains is one of the best examples of inter-progenitor pool wiring. However, Drosophila visual system development has revealed similar mechanisms in invertebrate brains, suggesting that inter-progenitor pool wiring is an evolutionarily conserved strategy that expands neural circuit diversity. Here, we will discuss how inter-progenitor pool wiring is accomplished in mammalian and fly brain systems. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Radiation inactivation target size of rat adipocyte glucose transporters in the plasma membrane and intracellular pools

    International Nuclear Information System (INIS)

    Jacobs, D.B.; Berenski, C.J.; Spangler, R.A.; Jung, C.Y.

    1987-01-01

    The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and 109,000 daltons prior to and after insulin treatment, respectively. In the case of microsomal membranes, however, inactivation data showed anomalously low radiation sensitivities at low radiation doses, which may be interpreted as indicating the presence of a radiation-sensitive inhibitor. These results suggest that the adipocyte glucose transporter occurs as a monomer in the plasma membrane while existing in the intracellular reserve pool either as a homodimer or as a stoichiometric complex with a protein of an approximately equal size

  9. Impacts of exotic mangroves and mangrove control on tide pool fish assemblages

    Science.gov (United States)

    Richard A. MacKenzie; Cailtin L. Kryss

    2013-01-01

    Fish were sampled from tide pools in Hawaii to determine how exotic mangroves Rhizophora mangle and the use of herbicides to chemically eradicate them are impacting tide pool fish assemblages. Ecological parameters were compared among mangrove-invaded, native vegetated, and non-vegetated tide pools before and after mangroves had been chemically...

  10. Experimental investigation on the weld pool formation process in plasma keyhole arc welding

    Science.gov (United States)

    Van Anh, Nguyen; Tashiro, Shinichi; Van Hanh, Bui; Tanaka, Manabu

    2018-01-01

    This paper seeks to clarify the weld pool formation process in plasma keyhole arc welding (PKAW). We adopted, for the first time, the measurement of the 3D convection inside the weld pool in PKAW by stereo synchronous imaging of tungsten tracer particles using two sets of x-ray transmission systems. The 2D convection on the weld pool surface was also measured using zirconia tracer particles. Through these measurements, the convection in a wide range of weld pools from the vicinity of the keyhole to the rear region was successfully visualized. In order to discuss the heat transport process in a weld pool, the 2D temperature distribution on the weld pool surface was also measured by two-color pyrometry. The results of the comprehensive experimental measurement indicate that the shear force due to plasma flow is found to be the dominant driving force in the weld pool formation process in PKAW. Thus, heat transport in a weld pool is considered to be governed by two large convective patterns near the keyhole: (1) eddy pairs on the surface (perpendicular to the torch axis), and (2) eddy pairs on the bulk of the weld pool (on the plane of the torch). They are formed with an equal velocity of approximately 0.35 m s-1 and are mainly driven by shear force. Furthermore, the flow velocity of the weld pool convection becomes considerably higher than that of other welding processes, such as TIG welding and GMA welding, due to larger plasma flow velocity.

  11. A hierarchic sustainability dashboard to evaluate logistics pooling

    OpenAIRE

    Morana, Joëlle; Gonzalez-Feliu, Jesus

    2014-01-01

    Logistics pooling is now a major challenge in supply chain management, though it remains a little known activity in which the different actors involved use different approaches whose objectives are not always the same and with sometimes conflicting standpoints. This purpose of this article is to define, on the basis of a detailed analysis of the literature, a grid for interpreting and a dashboard for evaluating the sustainable performance of pooled delivery systems. Firstly, an analysis of th...

  12. Models for Pooled Time-Series Cross-Section Data

    Directory of Open Access Journals (Sweden)

    Lawrence E Raffalovich

    2015-07-01

    Full Text Available Several models are available for the analysis of pooled time-series cross-section (TSCS data, defined as “repeated observations on fixed units” (Beck and Katz 1995. In this paper, we run the following models: (1 a completely pooled model, (2 fixed effects models, and (3 multi-level/hierarchical linear models. To illustrate these models, we use a Generalized Least Squares (GLS estimator with cross-section weights and panel-corrected standard errors (with EViews 8 on the cross-national homicide trends data of forty countries from 1950 to 2005, which we source from published research (Messner et al. 2011. We describe and discuss the similarities and differences between the models, and what information each can contribute to help answer substantive research questions. We conclude with a discussion of how the models we present may help to mitigate validity threats inherent in pooled time-series cross-section data analysis.

  13. Evaluation of Decontamination Factor of Aerosol in Pool Scrubber according to Bubble Shape and Size

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Hyun Joung; Ha, Kwang Soon; Jang, Dong Soon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The scrubbing pool could play an important role in the wet type FCVS because a large amount of aerosol is captured in the water pool. The pool scrubbing phenomena have been modelled and embedded in several computer codes, such as SPARC (Suppression Pool Aerosol Removal Code), BUSCA (BUbble Scrubbing Algorithm) and SUPRA (Suppression Pool Retention Analysis). These codes aim at simulating the pool scrubbing process and estimating the decontamination factors (DFs) of the radioactive aerosol and iodine gas in the water pool, which is defined as the ratio of initial mass of the specific radioactive material to final massy after passing through the water pool. The pool scrubbing models were reviewed and an aerosol scrubbing code has been prepared to calculate decontamination factor through the pool. The developed code has been verified using the experimental results and parametric studies the decontamination factor according to bubble shape and size. To evaluate the decontamination factor more accurate whole pool scrubber phenomena, the code was improved to consider the variety shape and size of bubbles. The decontamination factor were largely evaluated in ellipsoid bubble rather than in sphere bubble. The pool scrubbing models will be enhanced to apply more various model such as aerosol condensation of hygroscopic. And, it is need to experiment to measure to bubble shape and size distribution in pool to improve bubble model.

  14. Heat and Fission Product Transport in a Molten U-Zr-O Pool With Crust

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2002-01-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the pool. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool was estimated by product of the mass concentration and energy conversion factor of each fission product. For the calculation of heat generation rate in the pool, twenty-nine elements were chosen and classified by their chemical properties. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis was performed for the TMI-2 accident. The pool is assumed to be a partially filled hemispherical geometry and the change of pool geometry during the numerical calculation was neglected. Results of the numerical calculation revealed that the peak temperature of the molten pool significantly decreased and most of the volatile fission products were released from the molten pool during the accident. (authors)

  15. Greenland Tidal Pools as Hot Spots for Ecosystem Metabolism and Calcification

    KAUST Repository

    Duarte, Carlos M.; Krause-Jensen, Dorte

    2018-01-01

    The hypothesis that Arctic tidal pools provide environmental conditions suitable for calcifiers during summer, thereby potentially providing refugia for calcifiers in an acidifying Arctic Ocean, was tested on the basis of measurements conducted during two midsummers (2014 and 2016) in tidal pools colonised by a community composed of macroalgae and calcifiers in Disko Bay, Greenland (69° N). The tidal pools exhibited steep diurnal variations in temperature from a minimum of about 6 °C during the night to a maximum of almost 18 °C in the afternoon, while the temperature of the surrounding shore water was much lower, typically in the range 3 to 8 °C. O2 concentrations in the tidal pools were elevated relative to those in the adjacent open waters, by up to 11 mg O2 L−1, and exhibited heavy super-saturation (up to > 240%) during daytime emersion, reflecting intense and sustained photosynthetic rates of the tidal macroalgae. The intense photosynthetic activity of the seaweeds resulted in the drawdown of pCO2 concentrations in the pools during the day to levels down to average (±SE) values of 66 ± 18 ppm, and a minimum recorded value of 14.7 ppm, corresponding to pH levels as high as 8.69 ± 0.08, as compared to CO2 levels of 256 ± 4 and pH levels of 8.14 ± 0.01 in the water flooding the pools during high tide. The corresponding Ωarag reached 5.04 ± 0.49 in the pools as compared to 1.55 ± 0.02 in the coastal waters flooding the pools. Net calcification averaged 9.6 ± 5.6 μmol C kg−1 h−1 and was strongly and positively correlated with calculated net ecosystem production rates, which averaged 27.5 ± 8.6 μmol C kg−1 h−1. Arctic tidal pools promote intense metabolism, creating conditions suitable for calcification during the Arctic summer, and can, therefore, provide refugia from ocean acidification to vulnerable calcifiers as extended periods of continuous light during summer are conducive to suitable conditions

  16. Greenland Tidal Pools as Hot Spots for Ecosystem Metabolism and Calcification

    KAUST Repository

    Duarte, Carlos M.

    2018-01-18

    The hypothesis that Arctic tidal pools provide environmental conditions suitable for calcifiers during summer, thereby potentially providing refugia for calcifiers in an acidifying Arctic Ocean, was tested on the basis of measurements conducted during two midsummers (2014 and 2016) in tidal pools colonised by a community composed of macroalgae and calcifiers in Disko Bay, Greenland (69° N). The tidal pools exhibited steep diurnal variations in temperature from a minimum of about 6 °C during the night to a maximum of almost 18 °C in the afternoon, while the temperature of the surrounding shore water was much lower, typically in the range 3 to 8 °C. O2 concentrations in the tidal pools were elevated relative to those in the adjacent open waters, by up to 11 mg O2 L−1, and exhibited heavy super-saturation (up to > 240%) during daytime emersion, reflecting intense and sustained photosynthetic rates of the tidal macroalgae. The intense photosynthetic activity of the seaweeds resulted in the drawdown of pCO2 concentrations in the pools during the day to levels down to average (±SE) values of 66 ± 18 ppm, and a minimum recorded value of 14.7 ppm, corresponding to pH levels as high as 8.69 ± 0.08, as compared to CO2 levels of 256 ± 4 and pH levels of 8.14 ± 0.01 in the water flooding the pools during high tide. The corresponding Ωarag reached 5.04 ± 0.49 in the pools as compared to 1.55 ± 0.02 in the coastal waters flooding the pools. Net calcification averaged 9.6 ± 5.6 μmol C kg−1 h−1 and was strongly and positively correlated with calculated net ecosystem production rates, which averaged 27.5 ± 8.6 μmol C kg−1 h−1. Arctic tidal pools promote intense metabolism, creating conditions suitable for calcification during the Arctic summer, and can, therefore, provide refugia from ocean acidification to vulnerable calcifiers as extended periods of continuous light during summer are conducive to suitable conditions

  17. 7 CFR 1126.7 - Pool plant.

    Science.gov (United States)

    2010-01-01

    ... excluded from the supply plant's shipments in computing the plant's shipping percentage. (d) A plant... part, or the plant has automatic pooling status under the other Federal order; and (7) That portion of...

  18. Equilibrium blood pool scanning in the evaluation of hemophilic arthropathy

    International Nuclear Information System (INIS)

    Spies, S.; Green, D.; Rana, N.A.; Milgram, J.W.; Mintzer, R.

    1978-01-01

    Arthropathy was evaluated in six patients with severe hemophilia (factor VIII<1%) using the technique of blood pool scanning. Employing an in vivo method for erythrocyte labelling with technetium-99m, a dynamic perfusion sequence was obtained using a scintillation camera over the joint(s) to be examined. Subsequently, equilibrium blood pool images of the joints were obtained to determine regional blood volume. In young patients with repeated episodes of acute hemarthrosis, increased vascularity and increased blood pool in the affected joints were demonstrated. In older patients with fixed, contracted joints and degenerative arthropathy, vascularity and regional blood volume were not abnormal. Blood pool scanning is a safe, non-invasive technique that augments the clinical and radiographic examination of the joints. The method is helpful in distinguishing acute joint bleeding from chronic synovitis and arthritis, and may prove useful in selecting patients for synovectomy. (author)

  19. Diversity and structure of microcrustacean assemblages (Cladocera and Copepoda and limnological variability in perennial and intermittent pools in a semi-arid region, Bahia, Brazil

    Directory of Open Access Journals (Sweden)

    Nadson R. Simões

    2011-12-01

    Full Text Available Temporary wetlands undergo recurrent drought due to the scarcity of water, which disrupts the hydrological connectivity with adjacent aquatic systems. However, some environments retain water for longer periods, allowing greater persistence of the community. The current study evaluated differences in the microcrustacean assemblages and limnological variability between perennial and intermittent pools in a semi-arid region of Brazil. The abiotic features (water temperature, pH, total alkalinity, electrical conductivity and depth of intermittent pools were affected more than perennial pools due to loss of water volume. This may have contributed to a higher average richness and diversity index in some intermittent pools and differences in the structure of the assemblages. The lowest species richness and diversity were recorded where physical factors, such as a large quantity of suspended solids and variability in the electrical conductivity of the water and pH, make the environment unsuitable for these organisms. These results suggest that community development in intermittent pools is interrupted by the dry season; when the water returns, due to rainfall or rising groundwater, each pond undergoes a different process of colonization. In these circumstances, the biological importance of temporary aquatic environments is clear, since such pools provide shelters and have an important role in the maintenance of the regional diversity of aquatic environments.

  20. Clean-up system for pool water in pressure suppression chamber and operation method therefor

    Energy Technology Data Exchange (ETDEWEB)

    Hirabayashi, Kentaro; Kinoshita, Shoichiro

    1996-09-17

    Pool water in a pressure suppression chamber of a BWR type reactor is sucked by a pump of an after-heat removing system. The pool water pressurized here is sent to the pressure suppression chamber by way of a heat exchanger and a test line backwarding pipeline to stir the pool water in the pressure suppression chamber. Further, the pool water pressurized by the pump is sent to the pressure suppression chamber by way of a filtration desalting device and an exit pipe to purify the pool water. Upon cleaning of pipelines before the start of a periodical test, the pool water sucked by the pump is sent to the filtration desalting device and recovered to the pressure suppression chamber. This can reduce the amount of impurities carried to the suppression chamber. After the cleaning of the pipelines, pool water is passed through the test line backwarding pipeline, so that the pool water can be stirred at the same time. (I.N.)

  1. Pump/heat exchanger assembly for pool-type reactor

    International Nuclear Information System (INIS)

    Nathenson, R.D.; Slepian, R.M.

    1987-01-01

    A heat exchanger and pump assembly comprising a heat exchanger including a housing for defining an annularly shaped cavity and supporting therein a plurality of heat transfer tubes. A pump is disposed beneath the heat exchanger and is comprised of a plurality of flow couplers disposed in a circular array. Each flow coupler is comprised of a pump duct for receiving a first electrically conductive fluid, i.e. the primary liquid metal, from a pool thereof, and a generator duct for receiving a second electrically conductive fluid, i.e. the intermediate liquid metal. The primary liquid metal is introduced from the reactor pool into the top, inlet ends of the tubes, flowing downward therethrough to be discharged from the tubes' bottom ends directly into the reactor pool. The primary liquid metal is variously introduced into the pump ducts directly from the reactor pool, either from the bottom or top end of the flow coupler. The intermediate fluid introduced into the generator ducts via the inlet duct and inlet plenum and after leaving the generator ducts passes through the annular cavity of the exchanger to cool the primary liquid in the tubes. The annular magnetic field of the pump is produced by a circular array of electromagnets having hollow windings cooled by a flow of the intermediate metal. (author)

  2. Sulfur redox chemistry governs diurnal antimony and arsenic cycles at Champagne Pool, Waiotapu, New Zealand

    Science.gov (United States)

    Ullrich, Maria K.; Pope, James G.; Seward, Terry M.; Wilson, Nathaniel; Planer-Friedrich, Britta

    2013-07-01

    Champagne Pool, a sulfidic hot spring in New Zealand, exhibits distinct diurnal variations in antimony (Sb) and arsenic (As) concentrations, with daytime high and night-time low concentrations. To identify the underlying mobilization mechanisms, five sites along the drainage channel of Champagne Pool were sampled every 2 h during a 24 h period. Temporal variations in elemental concentrations and Sb, As, and sulfur (S) speciation were monitored in the discharging fluid. Total trace element concentrations in filtered and unfiltered samples were analyzed using ICP-MS, and Sb, As and S species were determined by IC-ICP-MS. Sulfur speciation in the drainage channel was dominated by thiosulfate and sulfide at night, while sulfate dominated during the day. The distinct diurnal changes suggest that the transformations are caused by phototrophic sulfur-oxidizing bacteria. These bacteria metabolize thiosulfate and sulfide in daylight to form sulfate and, as suggested by modeling with PhreeqC, elemental sulfur. Sulfide consumption during the day results in undersaturation of antimony sulfides, which triggers the additional release of dissolved Sb. For As, diurnal cycles were much more pronounced in speciation than in total concentrations, with di- and trithioarsenate forming at night due to excess sulfide, and monothioarsenate forming from arsenite and elemental sulfur during the day. Sulfur speciation was thus found to control Sb and As in terms of both solubility and speciation.

  3. Validation analysis of pool fire experiment (Run-F7) using SPHINCS code

    International Nuclear Information System (INIS)

    Yamaguchi, Akira; Tajima, Yuji

    1998-04-01

    SPHINCS (Sodium Fire Phenomenology IN multi-Cell System) code has been developed for the safety analysis of sodium fire accident in a Fast Breeder Reactor. The main features of the SPHINCS code with respect to the sodium pool fire phenomena are multi-dimensional modeling of the thermal behavior in sodium pool and steel liner, modeling of the extension of sodium pool area based on the sodium mass conservation, and equilibrium model for the chemical reaction of pool fire on the flame sheet at the surface of sodium pool during. Therefore, the SPHINCS code is capable of temperature evaluation of the steel liner in detail during the small and/or medium scale sodium leakage accidents. In this study, Run-F7 experiment in which the sodium leakage rate is 11.8 kg/hour has been analyzed. In the experiment the diameter of the sodium pool is approximately 60 cm and the maximum steel liner temperature was 616 degree C. The analytical results tell us the agreement between the SPHINCS analysis and the experiment is excellent with respect to the time history and spatial distribution of the liner temperature, sodium pool extension behavior, as well as atmosphere gas temperature. It is concluded that the pool fire modeling of the SPHINCS code has been validated for this experiment. The SPHINCS code is currently applicable to the sodium pool fire phenomena and the temperature evaluation of the steel liner. The experiment series are continued to check some parameters, i.e., sodium leakage rate and the height of sodium leakage. Thus, the author will analyze the subsequent experiments to check the influence of the parameters and applies SPHINCS to the sodium fire consequence analysis of fast reactor. (author)

  4. Analysis of radiation shields of BNPP spent fuel pool

    International Nuclear Information System (INIS)

    Ayoobian, N.; Hadad, K.; Nematollahi, M. R.

    2007-01-01

    Radioactive protection is one of the most important subjects in nuclear power plants safety. Analysis of BNPP spent fuel pool shielding , as a main source of energetic γ-rays was the main goal of this project. Firstly, we simulated the reactor core using WIMSD-4 neutronic code and the amount of fission product in the fuel assembly (FA) was calculated during the reactor operation. Then, by obtaining the results from the previous calculation and by using MCNP4C nuclear code , the intensity of γ-rays was obtained in layers of spent fuel pool shields. The results have shown that no significant γ-rays passed through these shields. Finally, an accident and resulting exposure dose above the pool was analyzed

  5. Analyzing data distribution on disk pools for dCache

    Energy Technology Data Exchange (ETDEWEB)

    Halstenberg, S; Jung, C; Ressmann, D [Forschungszentrum Karlsruhe, Steinbuch Centre for Computing, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2010-04-01

    Most Tier-1 centers of LHC Computing Grid are using dCache as their storage system. dCache uses a cost model incorporating CPU and space costs for the distribution of data on its disk pools. Storage resources at Tier-1 centers are usually upgraded once or twice a year according to given milestones. One of the effects of this procedure is the accumulation of heterogeneous hardware resources. For a dCache system, a heterogeneous set of disk pools complicates the process of weighting CPU and space costs for an efficient distribution of data. In order to evaluate the data distribution on the disk pools, the distribution is simulated in Java. The results are discussed and suggestions for improving the weight scheme are given.

  6. Removal of volatile iodine from gas bubbles rising in water pools: review and assessment of pool scrubbing codes

    Energy Technology Data Exchange (ETDEWEB)

    Polo, J; Herranz, L E; Peyres, V; Escudero, M [CIEMAT, Nuclear Technology Institute, Madrid (Spain)

    1996-12-01

    During a hypothetical nuclear reactor accident with core damage the fission products released from the degrading fuel bundles often pass through aqueous beds before entering the containment, mitigating in part the source term. Several computer codes have been developed for predicting the fission product and aerosols removal in pool scrubbing scenarios. In addition to particle removal, these codes simulate the retention of some volatile iodine compounds. In this work a review of volatile iodine removal models included in SPARC and BUSCA codes is presented. Besides, the results and discussions of a validation of both codes against the available experimental data are summarized. SPARC and BUSCA codes model the diffusion of iodine toward the bubble interface by using the film penetration theory, which assumes a double layer gas-liquid at the interface. However, there are some differences between the two models, mainly related to the boundary conditions in the aqueous volume for the diffusion of molecular iodine. In SPARC, a set of fast reactions in the liquid phase control both the molecular iodine concentration in the pool and the partition coefficient of iodine at the interface. Thus, the aqueous chemistry plays an important role in the boundary conditions for the diffusion process. On the contrary, the BUSCA model has no chemical considerations at all, and assumes a null iodine concentration in the water bulk. Several sensitivity studies have been made in order to weight the effect of these differences. The variables examined in these studies were the pool temperature and the incoming iodine concentration in the pool. Additionally, sensitivity studies focused on the steam mass fraction of the injected gas were performed to study the effect of the different approach of both models for the condensation process. The results showed a different sensitivity of SPARC and BUSCA to the incoming concentration. (author) 5 tabs., 26 refs.

  7. 7 CFR 1001.7 - Pool plant.

    Science.gov (United States)

    2010-01-01

    ... excluded from the supply plant's shipments in computing the percentages in paragraphs (c)(1) and (2) of... plant has automatic pooling status under the other Federal order. [64 FR 47954, Sept. 1, 1999, as...

  8. Disinfection by-product formation of UV treated swimming pool water

    DEFF Research Database (Denmark)

    Spiliotopoulou, Aikaterini; Hansen, Kamilla Marie Speht; Andersen, Henrik Rasmus

    2015-01-01

    Water samples from 3 indoor swimming pool facilities were tested to evaluate UV-induced effects on swimming pool water chemistry. Concentration change of several DBPs was investigated in experiments including medium pressure UV treatment with and without chlorine and post-UV chlorination. Post-UV...

  9. Pseudomonas aeruginosa in Swimming Pool Water: Evidences and Perspectives for a New Control Strategy

    Directory of Open Access Journals (Sweden)

    Marco Guida

    2016-09-01

    Full Text Available Pseudomonas aeruginosa is frequently isolated in swimming pool settings. Nine recreational and rehabilitative swimming pools were monitored according to the local legislation. The presence of P. aeruginosa was correlated to chlorine concentration. The ability of the isolates to form a biofilm on plastic materials was also investigated. In 59.5% of the samples, microbial contamination exceeded the threshold values. P. aeruginosa was isolated in 50.8% of these samples. The presence of P. aeruginosa was not correlated with free or total chlorine amount (R2 < 0.1. All the isolates were moderate- to strong-forming biofilm (Optical Density O.D.570 range 0.7–1.2. To control biofilm formation and P. aeruginosa colonization, Quantum FreeBioEnergy© (QFBE, FreeBioEnergy, Brisighella, Italy, has been applied with encouraging preliminary results. It is a new, promising control strategy based on the change of an electromagnetic field which is responsible for the proliferation of some microorganisms involved in biofilm formation, such as P. aeruginosa.

  10. Fuel assembly storage pool

    International Nuclear Information System (INIS)

    Hiranuma, Hiroshi.

    1976-01-01

    Object: To remove limitation of the number of storage of fuel assemblies to increase the number of storage thereof so as to relatively reduce the water depth required for shielding radioactive rays. Structure: Fuel assembly storage rack containers for receiving a plurality of spent fuel assembly racks are stacked in multi-layer fashion within a storage pool filled with water for shielding radioactive rays and removing heat. (Furukawa, Y.)

  11. Determination of isotopomers in pools of molecules with polyisotopic elements

    International Nuclear Information System (INIS)

    Zyakun, A.M.; Brenninkmeijer, C.A.M.

    2002-01-01

    Polyisotopic element atoms that are present in a molecule form a pool of isotopomer molecules. Mono- and polyisotopomers are distinguished depending on the quantity of atoms of polyisotopic elements. Methodical approaches have been considered for the quantitative determination of the isotope composition of an element included in mono- and polyisotopic molecules. A possibility of the equally probable (homogeneous) and non-equally probable (non-homogeneous) distribution of isotopes of a polyisotopic element, the atoms of which have different positions in the molecule of polyisotopomer, has been shown. Factors disturbing the homogeneous distribution of isotopes of the element in the polyisotopomer pool have been revealed. When a polyisotopomer is involved in a mass-dependent process or reaction, the homogeneity of isotope distribution of the element is disturbed both in the residual and newly formed pools of polyisotopomer. By the example of CO 2 (polyisotopomer by oxygen) it has been shown that one can judge of the history of the analyzed pool formation by distribution of oxygen isotopes within this pool. The isotope content in the oxygen sites of polyisotopomer is a diagnostic feature of CO 2 involvement in the efflux from a reservoir or influx to the analyzed reservoir from an external source. (author)

  12. Development of INSPCT-S for inspection of spent fuel pool

    Energy Technology Data Exchange (ETDEWEB)

    Walters, W.; Haghighat, A. [Nuclear Engineering Program, Mechanical Engineering Dept., Virginia Tech., Blacksburg, VA 24061 (United States); Sitaraman, S.; Ham, Y. [Lawrence Livermore National Laboratory, 7000 East Ave., Livermore, CA 94550 (United States)

    2011-07-01

    In this paper, we discuss an accurate and fast software tool (INSPCT-S, Inspection of Nuclear Spent fuel-Pool Calculation Tool, version Spreadsheet) developed for calculation of the response of fission chambers placed in a spent fuel pool, such as Atucha-I. INSPCT-S is developed for identification of suspicious regions of the pool that may have missing or substitute assemblies. INSPCT-S uses a hybrid algorithm based on the adjoint function methodology. The neutron source is comprised of spontaneous fission, ({alpha}, n) interactions, and subcritical multiplication. The former is evaluated using the ORIGEN-ARP code, and the latter is obtained with the fission matrix (FM) formulation. The FM coefficients are determined using the MCNP Monte Carlo code, and the importance function is determined using the PENTRAN 3-D parallel Sn code. Three databases for the neutron source, FM elements, and adjoint flux are prepared as functions of different parameters including burnup, cooling time, enrichment, and pool lattice size. INSPCT-S uses the aforementioned databases and systems of equations to calculate detector responses, which are subsequently compared with normalized experimental data. If this comparison is not satisfied, INSPCT-S utilizes color coding to identify the suspicious regions of a spent fuel pool. (authors)

  13. Adherence to a Mediterranean-style diet and incident fractures: pooled analysis of observational evidence.

    Science.gov (United States)

    Kunutsor, Setor K; Laukkanen, Jari A; Whitehouse, Michael R; Blom, Ashley W

    2018-06-01

    The Mediterranean diet is associated with decreased morbidity and mortality from various chronic diseases. Adherence to a Mediterranean-style diet has been suggested to have protective effects on bone health and decreases the incidence of bone fractures, but the evidence is not clear. We conducted a systematic review and meta-analysis of available observational studies to quantify the association between adherence to a Mediterranean-style diet, as assessed by the Mediterranean Diet Score (MDS), and the risk of fractures in the general population. Relevant studies were identified in a literature search of MEDLINE, EMBASE, Web of Science, and reference lists of relevant studies to October 2016. Relative risks (RRS) with 95% confidence intervals (CIs) were aggregated using random-effects models. Five observational studies with data on 353,076 non-overlapping participants and 33,576 total fractures (including 6,881 hip fractures) were included. The pooled fully adjusted RR (95% CI) for hip fractures per 2-point increment in adherence to the MDS was 0.82 (0.71-0.96). Adherence to the MDS was not associated with the risk of any or total fractures based on pooled analysis of only two studies. Limited observational evidence supports a beneficial effect of adherence to a Mediterranean-style diet on the incidence of hip fractures. Well-designed intervention studies are needed to elucidate the relationship between adherence to a Mediterranean-style diet and the risk of adverse bone health outcomes such as fractures.

  14. Mathematical modelling and simulation of the thermal performance of a solar heated indoor swimming pool

    OpenAIRE

    Mančić Marko V.; Živković Dragoljub S.; Milosavljević Peđa M.; Todorović Milena N.

    2014-01-01

    Buildings with indoor swimming pools have a large energy footprint. The source of major energy loss is the swimming pool hall where air humidity is increased by evaporation from the pool water surface. This increases energy consumption for heating and ventilation of the pool hall, fresh water supply loss and heat demand for pool water heating. In this paper, a mathematical model of the swimming pool was made to assess energy demands of an indoor swimming po...

  15. Measure Guideline: Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.; Easley, S.

    2012-05-01

    The report evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provide a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  16. Spent fuel pool thermal-hydraulic analysis using RELAP5-3D

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, M. C.; Fernandes, G.H.N.; Costa, A.L.; Pereira, F.; Pereira, C., E-mail: marc5663@gmail.com, E-mail: ghnfernandes@pq.cnpq.br, E-mail: claubia@nuclear.ufmg.br, E-mail: antonella@nuclear.ufmg.br [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    In order to analyze the thermo-hydraulic behavior of spent fuel pools, and taking as reference a hypothetic PWR nuclear plant, a model of RELAP-3D for a spent fuel pool has been built. This model has been used to simulate a loss of coolant in SPF. This study focuses on the loss of coolant flow accident in spent fuel storage pool which is modelled by using RELAP5-3D code to observe the coolant level reduction and fuel uncovery because of decay heat generation of the spent fuel in the pool. The results have been compared with the available data. The developed model demonstrated that the RELAP5-3D is capable of reproduce the thermal behavior of SPF in a transient scenario. (author)

  17. Condensation of vapor bubble in subcooled pool

    Science.gov (United States)

    Horiuchi, K.; Koiwa, Y.; Kaneko, T.; Ueno, I.

    2017-02-01

    We focus on condensation process of vapor bubble exposed to a pooled liquid of subcooled conditions. Two different geometries are employed in the present research; one is the evaporation on the heated surface, that is, subcooled pool boiling, and the other the injection of vapor into the subcooled pool. The test fluid is water, and all series of the experiments are conducted under the atmospheric pressure condition. The degree of subcooling is ranged from 10 to 40 K. Through the boiling experiment, unique phenomenon known as microbubble emission boiling (MEB) is introduced; this phenomenon realizes heat flux about 10 times higher than the critical heat flux. Condensation of the vapor bubble is the key phenomenon to supply ambient cold liquid to the heated surface. In order to understand the condensing process in the MEB, we prepare vapor in the vapor generator instead of the evaporation on the heated surface, and inject the vapor to expose the vapor bubble to the subcooled liquid. Special attention is paid to the dynamics of the vapor bubble detected by the high-speed video camera, and on the enhancement of the heat transfer due to the variation of interface area driven by the condensation.

  18. Spent nuclear fuel storage pool thermal-hydraulic analysis

    International Nuclear Information System (INIS)

    Gay, R.R.

    1984-01-01

    Storage methods and requirements for spent nuclear fuel at U.S. commercial light water reactors are reviewed in Section 1. Methods of increasing current at-reactor storage capabilities are also outlined. In Section 2 the development of analytical methods for the thermal-hydraulic analysis of spent fuel pools is chronicled, leading up to a discussion of the GFLOW code which is described in Section 3. In Section 4 the verification of GFLOW by comparisons of the code's predictions to experimental data taken inside the fuel storage pool at the Maine Yankee nuclear power plant is presented. The predictions of GFLOW using 72, 224, and 1584 node models of the storage pool are compared to each other and to the experimental data. An example of thermal licensing analysis for Maine Yankee using the GFLOW code is given in Section 5. The GFLOW licensing analysis is compared to previous licensing analysis performed by Yankee Atomic using the RELAP-4 computer code

  19. Spent Fuel Pool Dose Rate Calculations Using Point Kernel and Hybrid Deterministic-Stochastic Shielding Methods

    International Nuclear Information System (INIS)

    Matijevic, M.; Grgic, D.; Jecmenica, R.

    2016-01-01

    This paper presents comparison of the Krsko Power Plant simplified Spent Fuel Pool (SFP) dose rates using different computational shielding methodologies. The analysis was performed to estimate limiting gamma dose rates on wall mounted level instrumentation in case of significant loss of cooling water. The SFP was represented with simple homogenized cylinders (point kernel and Monte Carlo (MC)) or cuboids (MC) using uranium, iron, water, and dry-air as bulk region materials. The pool is divided on the old and new section where the old one has three additional subsections representing fuel assemblies (FAs) with different burnup/cooling time (60 days, 1 year and 5 years). The new section represents the FAs with the cooling time of 10 years. The time dependent fuel assembly isotopic composition was calculated using ORIGEN2 code applied to the depletion of one of the fuel assemblies present in the pool (AC-29). The source used in Microshield calculation is based on imported isotopic activities. The time dependent photon spectra with total source intensity from Microshield multigroup point kernel calculations was then prepared for two hybrid deterministic-stochastic sequences. One is based on SCALE/MAVRIC (Monaco and Denovo) methodology and another uses Monte Carlo code MCNP6.1.1b and ADVANTG3.0.1. code. Even though this model is a fairly simple one, the layers of shielding materials are thick enough to pose a significant shielding problem for MC method without the use of effective variance reduction (VR) technique. For that purpose the ADVANTG code was used to generate VR parameters (SB cards in SDEF and WWINP file) for MCNP fixed-source calculation using continuous energy transport. ADVATNG employs a deterministic forward-adjoint transport solver Denovo which implements CADIS/FW-CADIS methodology. Denovo implements a structured, Cartesian-grid SN solver based on the Koch-Baker-Alcouffe parallel transport sweep algorithm across x-y domain blocks. This was first

  20. 13 CFR 120.1703 - Qualifications to be a Pool Originator.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Qualifications to be a Pool Originator. 120.1703 Section 120.1703 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools...

  1. Measure Guideline. Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States); Easley, S. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States)

    2012-05-01

    This measure guideline evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provides a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  2. Molten pool characterization of laser lap welded copper and aluminum

    Science.gov (United States)

    Xue, Zhiqing; Hu, Shengsun; Zuo, Di; Cai, Wayne; Lee, Dongkyun; Elijah, Kannatey-Asibu, Jr.

    2013-12-01

    A 3D finite volume simulation model for laser welding of a Cu-Al lap joint was developed using ANSYS FLUENT to predict the weld pool temperature distribution, velocity field, geometry, alloying element distribution and transition layer thickness—all key attributes and performance characteristics for a laser-welded joint. Melting and solidification of the weld pool was simulated with an enthalpy-porosity formulation. Laser welding experiments and metallographic examination by SEM and EDX were performed to investigate the weld pool features and validate the simulated results. A bowl-shaped temperature field and molten pool, and a unique maximum fusion zone width were observed near the Cu-Al interface. Both the numerical simulation and experimental results indicate an arch-shaped intermediate layer of Cu and Al, and a gradual transition of Cu concentration from the aluminum plate to the copper plate with high composition gradient. For the conditions used, welding with Cu on top was found to result in a better weld joint.

  3. Molten pool characterization of laser lap welded copper and aluminum

    International Nuclear Information System (INIS)

    Xue, Zhiqing; Hu, Shengsun; Zuo, Di; Cai, Wayne; Lee, Dongkyun; Elijah, Kannatey-Asibu Jr

    2013-01-01

    A 3D finite volume simulation model for laser welding of a Cu–Al lap joint was developed using ANSYS FLUENT to predict the weld pool temperature distribution, velocity field, geometry, alloying element distribution and transition layer thickness—all key attributes and performance characteristics for a laser-welded joint. Melting and solidification of the weld pool was simulated with an enthalpy-porosity formulation. Laser welding experiments and metallographic examination by SEM and EDX were performed to investigate the weld pool features and validate the simulated results. A bowl-shaped temperature field and molten pool, and a unique maximum fusion zone width were observed near the Cu–Al interface. Both the numerical simulation and experimental results indicate an arch-shaped intermediate layer of Cu and Al, and a gradual transition of Cu concentration from the aluminum plate to the copper plate with high composition gradient. For the conditions used, welding with Cu on top was found to result in a better weld joint. (paper)

  4. Extra-binomial variation approach for analysis of pooled DNA sequencing data

    Science.gov (United States)

    Wallace, Chris

    2012-01-01

    Motivation: The invention of next-generation sequencing technology has made it possible to study the rare variants that are more likely to pinpoint causal disease genes. To make such experiments financially viable, DNA samples from several subjects are often pooled before sequencing. This induces large between-pool variation which, together with other sources of experimental error, creates over-dispersed data. Statistical analysis of pooled sequencing data needs to appropriately model this additional variance to avoid inflating the false-positive rate. Results: We propose a new statistical method based on an extra-binomial model to address the over-dispersion and apply it to pooled case-control data. We demonstrate that our model provides a better fit to the data than either a standard binomial model or a traditional extra-binomial model proposed by Williams and can analyse both rare and common variants with lower or more variable pool depths compared to the other methods. Availability: Package ‘extraBinomial’ is on http://cran.r-project.org/ Contact: chris.wallace@cimr.cam.ac.uk Supplementary information: Supplementary data are available at Bioinformatics Online. PMID:22976083

  5. Cells Lacking mtDNA Display Increased dNTP Pools upon DNA Damage

    DEFF Research Database (Denmark)

    Skovgaard, Tine; Rasmussen, Lene Juel; Munch-Petersen, Birgitte

    Imbalanced dNTP pools are highly mutagenic due to a deleterious effect on DNA polymerase fidelity. Mitochondrial DNA defects, including mutations and deletions, are commonly found in a wide variety of different cancer types. In order to further study the interconnection between dNTP pools...... and mitochondrial function we have examined the effect of DNA damage on dNTP pools in cells deficient of mtDNA. We show that DNA damage induced by UV irradiation, in a dose corresponding to LD50, induces an S phase delay in different human osteosarcoma cell lines. The UV pulse also has a destabilizing effect...... shows that normal mitochondrial function is prerequisite for retaining stable dNTP pools upon DNA damage. Therefore it is likely that mitochondrial deficiency defects may cause an increase in DNA mutations by disrupting dNTP pool balance....

  6. Convective Cold Pool Structure and Boundary Layer Recovery in DYNAMO

    Science.gov (United States)

    Savarin, A.; Chen, S. S.; Kerns, B. W.; Lee, C.; Jorgensen, D. P.

    2012-12-01

    One of the key factors controlling convective cloud systems in the Madden-Julian Oscillation (MJO) over the tropical Indian Ocean is the property of the atmospheric boundary layer. Convective downdrafts and precipitation from the cloud systems produce cold pools in the boundary layer, which can inhibit subsequent development of convection. The recovery time is the time it takes for the boundary layer to return to pre convective conditions. It may affect the variability of the convection on various time scales during the initiation of MJO. This study examines the convective cold pool structure and boundary layer recovery using the NOAA WP-3D aircraft observations, include the flight-level, Doppler radar, and GPS dropsonde data, collected during the Dynamics of MJO (DYNAMO) field campaign from November-December 2011. The depth and strength of convective cold pools are defined by the negative buoyancy, which can be computed from the dropsonde data. Convective downdraft can be affected by environmental water vapor due to entrainment. Mid-level dry air observed during the convectively suppressed phase of MJO seems to enhance convective downdraft, making the cold pools stronger and deeper. Recovery of the cold pools in the boundary layer is determined by the strength and depth of the cold pools and also the air-sea heat and moisture fluxes. Given that the water vapor and surface winds are distinct for the convectively active and suppressed phases of MJO over the Indian Ocean, the aircraft data are stratified by the two different large-scale regimes of MJO. Preliminary results show that the strength and depth of the cold pools are inversely correlated with the surrounding mid-level moisture. During the convectively suppressed phase, the recovery time is ~5-20 hours in relative weak wind condition with small air-sea fluxes. The recovery time is generally less than 6 hours during the active phase of MJO with moist mid-levels and stronger surface wind and air-sea fluxes.

  7. A swimming pool array for ultra high energy showers

    Science.gov (United States)

    Yodh, Gaurang B.; Shoup, Anthony; Barwick, Steve; Goodman, Jordan A.

    1992-11-01

    A very preliminary design concept for an array using water Cherenkov counters, built out of commercially available backyard swimming pools, to sample the electromagnetic and muonic components of ultra high energy showers at large lateral distances is presented. The expected performance of the pools is estimated using the observed lateral distributions by scintillator and water Cherenkov arrays at energies above 1019 eV and simulations.

  8. Impact and quantification of the sources of error in DNA pooling designs.

    Science.gov (United States)

    Jawaid, A; Sham, P

    2009-01-01

    The analysis of genome wide variation offers the possibility of unravelling the genes involved in the pathogenesis of disease. Genome wide association studies are also particularly useful for identifying and validating targets for therapeutic intervention as well as for detecting markers for drug efficacy and side effects. The cost of such large-scale genetic association studies may be reduced substantially by the analysis of pooled DNA from multiple individuals. However, experimental errors inherent in pooling studies lead to a potential increase in the false positive rate and a loss in power compared to individual genotyping. Here we quantify various sources of experimental error using empirical data from typical pooling experiments and corresponding individual genotyping counts using two statistical methods. We provide analytical formulas for calculating these different errors in the absence of complete information, such as replicate pool formation, and for adjusting for the errors in the statistical analysis. We demonstrate that DNA pooling has the potential of estimating allele frequencies accurately, and adjusting the pooled allele frequency estimates for differential allelic amplification considerably improves accuracy. Estimates of the components of error show that differential allelic amplification is the most important contributor to the error variance in absolute allele frequency estimation, followed by allele frequency measurement and pool formation errors. Our results emphasise the importance of minimising experimental errors and obtaining correct error estimates in genetic association studies.

  9. A general framework for the regression analysis of pooled biomarker assessments.

    Science.gov (United States)

    Liu, Yan; McMahan, Christopher; Gallagher, Colin

    2017-07-10

    As a cost-efficient data collection mechanism, the process of assaying pooled biospecimens is becoming increasingly common in epidemiological research; for example, pooling has been proposed for the purpose of evaluating the diagnostic efficacy of biological markers (biomarkers). To this end, several authors have proposed techniques that allow for the analysis of continuous pooled biomarker assessments. Regretfully, most of these techniques proceed under restrictive assumptions, are unable to account for the effects of measurement error, and fail to control for confounding variables. These limitations are understandably attributable to the complex structure that is inherent to measurements taken on pooled specimens. Consequently, in order to provide practitioners with the tools necessary to accurately and efficiently analyze pooled biomarker assessments, herein, a general Monte Carlo maximum likelihood-based procedure is presented. The proposed approach allows for the regression analysis of pooled data under practically all parametric models and can be used to directly account for the effects of measurement error. Through simulation, it is shown that the proposed approach can accurately and efficiently estimate all unknown parameters and is more computational efficient than existing techniques. This new methodology is further illustrated using monocyte chemotactic protein-1 data collected by the Collaborative Perinatal Project in an effort to assess the relationship between this chemokine and the risk of miscarriage. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Spent fuel and fuel pool component integrity. Annual report, FY 1979

    International Nuclear Information System (INIS)

    Johnson, A.B. Jr.; Bailey, W.J.; Schreiber, R.E.; Kustas, F.M.

    1980-05-01

    International meetings under the BEFAST program and under INFCE Working Group No. 6 during 1978 and 1979 continue to indicate that no cases of fuel cladding degradation have developed on pool-stored fuel from water reactors. A section from a spent fuel rack stand, exposed for 1.5 y in the Yankee Rowe (PWR) pool had 0.001- to 0.003-in.-deep (25- to 75-μm) intergranular corrosion in weld heat-affected zones but no evidence of stress corrosion cracking. A section of a 304 stainless steel spent fuel storage rack exposed 6.67 y in the Point Beach reactor (PWR) spent fuel pool showed no significant corrosion. A section of 304 stainless steel 8-in.-dia pipe from the Three Mile Island No. 1 (PWR) spent fuel pool heat exchanger plumbing developed a through-wall crack. The crack was intergranular, initiating from the inside surface in a weld heat-affected zone. The zone where the crack occurred was severely sensitized during field welding. The Kraftwerk Union (Erlangen, GFR) disassembled a stainless-steel fuel-handling machine that operated for 12 y in a PWR (boric acid) spent fuel pool. There was no evidence of deterioration, and the fuel-handling machine was reassembled for further use. A spent fuel pool at a Swedish PWR was decontaminated. The procedure is outlined in this report

  11. Cryptosporidium and Giardia in Swimming Pools, Atlanta, Georgia

    Centers for Disease Control (CDC) Podcasts

    2008-05-29

    In this podcast, Dan Rutz speaks with Dr. Joan Shields, a guest researcher with the Healthy Swimming Program at CDC, about an article in June 2008 issue of Emerging Infectious Diseases reporting on the results of a test of swimming pools in the greater Atlanta, Georgia area. Dr. Shields tested 160 pools in metro Atlanta last year for Cryptosporidium and Giardia. These germs cause most recreational water associated outbreaks.  Created: 5/29/2008 by Emerging Infectious Diseases.   Date Released: 5/29/2008.

  12. Analytical real-time measurement of a three-dimensional weld pool surface

    International Nuclear Information System (INIS)

    Zhang, WeiJie; Zhang, YuMing; Wang, XueWu

    2013-01-01

    The ability to observe and measure weld pool surfaces in real-time is the core of the foundation for next generation intelligent welding that can partially imitate skilled welders who observe the weld pool to acquire information on the welding process. This study aims at the real-time measurement of the specular three-dimensional (3D) weld pool surface under a strong arc in gas tungsten arc welding (GTAW). An innovative vision system is utilized in this study to project a dot-matrix laser pattern on the specular weld pool surface. Its reflection from the surface is intercepted at a distance from the arc by a diffuse plane. The intercepted laser dots illuminate this plane producing an image showing the reflection pattern. The deformation of this reflection pattern from the projected pattern (e.g. the dot matrix) is used to derive the 3D shape of the reflection surface, i.e., the weld pool surface. Based on careful analysis, the underlying reconstruction problem is formulated mathematically. An analytic solution is proposed to solve this formulated problem resulting in the weld pool surface being reconstructed on average in 3.04 ms during welding experiments. A vision-based monitoring system is thus established to measure the weld pool surface in GTAW in real-time. In order to verify the effectiveness of the proposed reconstruction algorithm, first numerical simulation is conducted. The proposed algorithm is then tested on a spherical convex mirror with a priori knowledge of its geometry. The detailed analysis of the measurement error validates the accuracy of the proposed algorithm. Results from the real-time experiments verify the robustness of the proposed reconstruction algorithm. (paper)

  13. 76 FR 72923 - Pool Corporation; Analysis To Aid Public Comment

    Science.gov (United States)

    2011-11-28

    ... manufacturers, warehouse them, and then resell the products to pool retail stores, pool service companies and.... ADDRESSES: Interested parties may file a comment online or on paper, by following the instructions in the... 0115'' on your comment, and file your comment online at https://ftcpublic.commentworks.com/ftc...

  14. Microvascular responses to (hyper-)gravitational stress by short-arm human centrifuge: arteriolar vasoconstriction and venous pooling.

    Science.gov (United States)

    Habazettl, H; Stahn, Alexander; Nitsche, Andrea; Nordine, Michael; Pries, A R; Gunga, H-C; Opatz, O

    2016-01-01

    We hypothesized that lower body microvessels are particularly challenged during exposure to gravity and hypergravity leading to failure of resistance vessels to withstand excessive transmural pressure during hypergravitation and gravitation-dependent microvascular blood pooling. Using a short-arm human centrifuge (SAHC), 12 subjects were exposed to +1Gz, +2Gz and +1Gz, all at foot level, for 4 min each. Laser Doppler imaging and near-infrared spectroscopy were used to measure skin perfusion and tissue haemoglobin concentrations, respectively. Pretibial skin perfusion decreased by 19% during +1Gz and remained at this level during +2Gz. In the dilated area, skin perfusion increased by 24 and 35% during +1Gz and +2Gz, respectively. In the upper arm, oxygenated haemoglobin (Hb) decreased, while deoxy Hb increased with little change in total Hb. In the calf muscle, O2Hb and deoxy Hb increased, resulting in total Hb increase by 7.5 ± 1.4 and 26.6 ± 2.6 µmol/L at +1Gz and +2Gz, respectively. The dynamics of Hb increase suggests a fast and a slow component. Despite transmural pressures well beyond the upper myogenic control limit, intact lower body resistance vessels withstand these pressures up to +2Gz, suggesting that myogenic control may contribute only little to increased vascular resistance. The fast component of increasing total Hb indicates microvascular blood pooling contributing to soft tissue capacitance. Future research will have to address possible alterations of these acute adaptations to gravity after deconditioning by exposure to micro-g.

  15. 7 CFR 1007.7 - Pool plant.

    Science.gov (United States)

    2010-01-01

    ...-upon use other than Class I shall be excluded from the supply plant's shipments in computing the plant... under the order in this part, or such plant has automatic pooling status under such other order. (h) Any...

  16. Analysis of implementing phase change materials in open-air swimming pools

    OpenAIRE

    Zsembinszki, Gabriel; Farid, Mohammed M.; Cabeza, Luisa F.

    2012-01-01

    Open-air swimming pools in Mediterranean climate regions are heated by direct solar radiation with no auxiliary heating systems. In order to extend the swimming season or improve comfort conditions, solar collectors or pool coverings may be used. In this paper, another approach was followed through the use of phase change materials (PCM). Two methods of introducing the PCM were considered: (1) encapsulated in the sidewalls and bottom of the pool, and (2) use the PCM in an external he...

  17. Characteristics of pools used by adult summer steelhead oversummering in the New River, California

    Science.gov (United States)

    Rodney J. Nakamoto

    1994-01-01

    Abstract - I assessed characteristics of pools used by oversummering adults of summer steelhead Oncorhynchus mykiss between July and October 1991 in the New River, northwestern California. Most fish occupied channel confluence pools and other pools of moderate size (200-1,200 m 2); these pools had less than 35% substrate embeddedness and mean water depths of about 1.0...

  18. CERN Electronics Pool presentations

    CERN Multimedia

    2011-01-01

    The CERN Electronics Pool has organised a series of presentations in collaboration with oscilloscope manufacturers. The last one will take place according to the schedule below.   Time will be available at the end of the presentation to discuss your personal needs. The Agilent presentation had to be postponed and will be organised later. -     Lecroy: Thursday, 24 November 2011, in 530-R-030, 14:00 to 16:30.

  19. Fuel-reduction management alters plant composition, carbon and nitrogen pools, and soil thaw in Alaskan boreal forest

    Science.gov (United States)

    Melvin, April M.; Celis, Gerardo; Johnstone, Jill F.; McGuire, A. David; Genet, Helene; Schuur, Edward A.G.; Rupp, T. Scott; Mack, Michelle C.

    2018-01-01

    Increasing wildfire activity in Alaska's boreal forests has led to greater fuel-reduction management. Management has been implemented to reduce wildfire spread, but the ecological impacts of these practices are poorly known. We quantified the effects of hand-thinning and shearblading on above- and belowground stand characteristics, plant species composition, carbon (C) and nitrogen (N) pools, and soil thaw across 19 black spruce (Picea mariana) dominated sites in interior Alaska treated 2-12 years prior to sampling. The density of deciduous tree seedlings was significantly higher in shearbladed areas compared to unmanaged forest (6.4 vs. 0.1 stems m−2), and unmanaged stands exhibited the highest mean density of conifer seedlings and layers (1.4 stems m−2). Understory plant community composition was most similar between unmanaged and thinned stands. Shearblading resulted in a near complete loss of aboveground tree biomass C pools while thinning approximately halved the C pool size (1.2 kg C m−2 compared to 3.1 kg C m−2 in unmanaged forest). Significantly smaller soil organic layer (SOL) C and N pools were observed in shearbladed stands (3.2 kg C m−2 and 116.8 g N m−2) relative to thinned (6.0 kg C m−2 and 192.2 g N m−2) and unmanaged (5.9 kg C m−2 and 178.7 g N m−2) stands. No difference in C and N pool sizes in the uppermost 10 cm of mineral soil was observed among stand types. Total C stocks for measured pools was 2.6 kg C m−2 smaller in thinned stands and 5.8 kg C m−2smaller in shearbladed stands when compared to unmanaged forest. Soil thaw depth averaged 13 cm deeper in thinned areas and 46 cm deeper in shearbladed areas relative to adjacent unmanaged stands, although variability was high across sites. Deeper soil thaw was linked to shallower SOL depth for unmanaged stands and both management types, however for any given SOL depth, thaw tended to be deeper in shearbladed areas compared to unmanaged forest. These findings indicate

  20. Induced venous pooling and cardiorespiratory responses to exercise after bed rest

    Science.gov (United States)

    Convertino, V. A.; Sandler, H.; Webb, P.; Annis, J. F.

    1982-01-01

    Venous pooling induced by a specially constructed garment is investigated as a possible means for reversing the reduction in maximal oxygen uptake regularly observed following bed rest. Experiments involved a 15-day period of bed rest during which four healthy male subjects, while remaining recumbent in bed, received daily 210-min venous pooling treatments from a reverse gradient garment supplying counterpressure to the torso. Results of exercise testing indicate that while maximal oxygen uptake endurance time and plasma volume were reduced and maximal heart rate increased after bed rest in the control group, those parameters remained essentially unchanged for the group undergoing venous pooling treatment. Results demonstrate the importance of fluid shifts and venous pooling within the cardiovascular system in addition to physical activity to the maintenance of cardiovascular conditioning.

  1. Trophic interactions among the heterotrophic components of plankton in man-made peat pools

    Directory of Open Access Journals (Sweden)

    Michał Niedźwiecki

    2017-03-01

    Full Text Available Man-made peat pools are permanent freshwater habitats developed due to non-commercial man-made peat extraction. Yet, they have not been widely surveyed in terms of ecosystem functioning, mainly regarding the complexity of heterotrophic components of the plankton. In this study we analysed distribution and trophic interrelations among heterotrophic plankton in man-made peat pools located in different types of peatbogs. We found that peat pools showed extreme differences in environmental conditions that occurred to be important drivers of distribution of microplankton and metazooplankton. Abundance of bacteria and protozoa showed significant differences, whereas metazooplankton was less differentiated in density among peat pools. In all peat pools stress-tolerant species of protozoa and metazoa were dominant. In each peat pool five trophic functional groups were distinguished. The abundance of lower functional trophic groups (bacteria, heterotrophic nanoflagellates (HNF and ciliates feeding on bacteria and HNF was weakly influenced by environmental drivers and was highly stable in all peat pool types. Higher functional trophic groups (naupli, omnivorous and carnivorous ciliates, cladocerans, adult copepods and copepodites were strongly influenced by environmental variables and exhibited lower stability. Our study contributes to comprehensive knowledge of the functioning of peat bogs, as our results have shown that peat pools are characterized by high stability of the lowest trophic levels, which can be crucial for energy transfer and carbon flux through food webs.

  2. Modeling of the Temperature Field Recovery in the Oil Pool

    Science.gov (United States)

    Khabibullin, I. L.; Davtetbaev, A. Ya.; Mar'in, D. F.; Khisamov, A. A.

    2018-05-01

    This paper considers the problem on mathematical modeling of the temperature field recovery in the oil pool upon termination of injection of water into the pool. The problem is broken down into two stages: injection of water and temperature and pressure recovery upon termination of injection. A review of the existing mathematical models is presented, analytical solutions for a number of cases have been constructed, and a comparison of the analytical solutions of different models has been made. In the general form, the expression has been obtained that permits determining the temperature change in the oil pool upon termination of injection of water (recovery of the temperature field).

  3. Clinical blood pool MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Leiner, Tim [Maastrich University Medical Center (Netherlands). Dept. of Radiology; Goyen, Martin [University Medical Center Hamburg-Eppendorf (Germany); Rohrer, Mathias [Bayer Schering Pharma AG, Berlin (Germany). European Business Unit Diagnostic Imaging; Schoenberg, Stefan O. (eds.) [University Hospital Mannheim Medical Faculty Mannheim - Heidelberg Univ. (Germany). Dept. of Clinical Radiology and Nuclear Medicine

    2008-07-01

    Clinical Blood Pool MR Imaging - This excellent treatise on Vasovist {sup registered} created by a team of exceptional faculty who are pioneers in MR Angiography covers the basic techniques, safety, efficacy, image processing and pharmaco-economic details to successfully implement a new level of MRA image quality with this new contrast agent. Martin Prince, Cornell University, New York The editors and authors have made groundbreaking contributions towards establishing MR angiography in various investigative settings, rendering it more precise and applying it for diverse indications. The work presented here is founded upon the extensive experience of the editors, as well as the broad range of experience from other scientific working groups. Maximilian Reiser, Ludwig Maximilian University, Munich Vasovist {sup registered} (Gadofosveset), worldwide the first blood pool agent, has only recently become available for clinical use, but has already gained wide acceptance as a tool to improve magnetic resonance angiography. This book presents the first in-depth introduction to the basic physicochemical aspects of the agent, the application of Vasovist {sup registered} in clinical MRA, as well as potential clinical applications beyond MRA and patient management-related aspects. The first part of the book explains basic and technical properties of the agent and the differences of Vasovist {sup registered} compared to currently available extracellular agents. The second part contains detailed chapters on safety and efficacy. In the third part the focus is on MR angiographic applications, and in the fourth part of the book potential clinical fields beyond MRA are explored. All clinical chapters feature ready-to-use clinical protocols and a series of take home messages that concisely summarize the current role of blood pool imaging for each specific indication. (orig.)

  4. 13 CFR 120.620 - SBA guarantee of a Pool Certificate.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false SBA guarantee of a Pool Certificate. 120.620 Section 120.620 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market The Sba Guarantee of A Certificate § 120.620 SBA guarantee of a Pool Certificate...

  5. 13 CFR 120.1726 - Pool Certificates a Seller cannot purchase.

    Science.gov (United States)

    2010-01-01

    ... that the Seller, or any of its Program Associates or Affiliates, originated or owned, and, in the event... LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1726 Pool Certificates a Seller cannot purchase. Neither a Seller, nor any of its Program...

  6. Safety classification of systems, structures, and components for pool-type research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Ryong [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2016-08-15

    Structures, systems, and components (SSCs) important to safety of nuclear facilities shall be designed, fabricated, erected, and tested to quality standards commensurate with the importance of the safety functions. Although SSC classification guidelines for nuclear power plants have been well established and applied, those for research reactors have been only recently established by the International Atomic Energy Agency (IAEA). Korea has operated a pool-type research reactor (the High Flux Advanced Neutron Application Reactor) and has recently exported another pool-type reactor (Jordan Research and Training Reactor), which is being built in Jordan. Korea also has a plan to build one more pool-type reactor, the Kijang Research Reactor, in Kijang, Busan. The safety classification of SSCs for pool-type research reactors is proposed in this paper based on the IAEA methodology. The proposal recommends that the SSCs of pool-type research reactors be categorized and classified on basis of their safety functions and safety significance. Because the SSCs in pool-type research reactors are not the pressure-retaining components, codes and standards for design of the SSCs following the safety classification can be selected in a graded approach.

  7. Estimation of reactor pool water temperature after shutdown in JRR-3M

    International Nuclear Information System (INIS)

    Yagi, Masahiro; Sato, Mitsugu; Kakefuda, Kazuhiro

    1999-01-01

    The reactor pool water temperature increasing by the decay heat was estimated by calculation. The reactor pool water temperature was calculated by increased enthalpy that was estimated by the reactor decay heat, the heat released from the reactor biological shielding concrete, reactor pool water surface, the heat conduction from the canal and the core inlet piping. These results of calculation were compared with the past measured data. As the results of estimation, after the JRR-3M shutdown, the calculated reactor pool temperature first increased sharply. This is because the decay heat was the major contribution. And then, rate of increased reactor pool temperature decreased. This is because the ratio of heat released from reactor biological shielding concrete and core inlet piping to the decay heat increased. Besides, the calculated reactor pool water temperature agreed with the past measured data in consequence of correcting the decay heat and the released heat. The corrected coefficient k 1 of decay heat was 0.74 - 0.80. And the corrected coefficient k 2 of heat released from the reactor biological shielding concrete was 3.5 - 4.5. (author)

  8. Allergies and risk of pancreatic cancer: a pooled analysis from the Pancreatic Cancer Case-Control Consortium.

    Science.gov (United States)

    Olson, Sara H; Hsu, Meier; Satagopan, Jaya M; Maisonneuve, Patrick; Silverman, Debra T; Lucenteforte, Ersilia; Anderson, Kristin E; Borgida, Ayelet; Bracci, Paige M; Bueno-de-Mesquita, H Bas; Cotterchio, Michelle; Dai, Qi; Duell, Eric J; Fontham, Elizabeth H; Gallinger, Steven; Holly, Elizabeth A; Ji, Bu-Tian; Kurtz, Robert C; La Vecchia, Carlo; Lowenfels, Albert B; Luckett, Brian; Ludwig, Emmy; Petersen, Gloria M; Polesel, Jerry; Seminara, Daniela; Strayer, Lori; Talamini, Renato

    2013-09-01

    In order to quantify the risk of pancreatic cancer associated with history of any allergy and specific allergies, to investigate differences in the association with risk according to age, gender, smoking status, or body mass index, and to study the influence of age at onset, we pooled data from 10 case-control studies. In total, there were 3,567 cases and 9,145 controls. Study-specific odds ratios and 95% confidence intervals were calculated by using unconditional logistic regression adjusted for age, gender, smoking status, and body mass index. Between-study heterogeneity was assessed by using the Cochran Q statistic. Study-specific odds ratios were pooled by using a random-effects model. The odds ratio for any allergy was 0.79 (95% confidence interval (CI): 0.62, 1.00) with heterogeneity among studies (P allergies or asthma. There were no major differences among subgroups defined by age, gender, smoking status, or body mass index. Older age at onset of allergies was slightly more protective than earlier age.

  9. Intravascular Papillary Endothelial Hyperplasia Associated with Venous Pool Arising in the Lower Lip: A Case Report

    Directory of Open Access Journals (Sweden)

    Hisanobu Yonezawa

    2009-01-01

    Full Text Available Intravascular papillary endothelial hyperplasia is a benign nonneoplastic vascular lesion that consists of endothelial cells with abundant vascular tissue with papillary proliferation. An adult female had a painless growing dark red nodule on the left side of the lower lip and often touched and gnawed at it for more than 4 years. The lesion was a tender, smooth mass approximately 1 cm in diameter without discoloration reaction. Magnetic resonance imaging of the lesion showed specific findings. She was diagnosed clinically as having mimicked hemangioma, and the lesion was totally excised under local anesthesia. Histopathological examination revealed that papillary proliferated endothelial cells with venous pool, and the lesion was diagnosed as intravascular papillary endothelial hyperplasia associated with venous pool. There has been no recurrence for more than 1 year. Despite the benign nature of this lesion, it could have been mistaken for a malignant tumor because of its clinical course and radiologic findings.

  10. Boosting Active Contours for Weld Pool Visual Tracking in Automatic Arc Welding

    DEFF Research Database (Denmark)

    Liu, Jinchao; Fan, Zhun; Olsen, Søren Ingvor

    2015-01-01

    Detecting the shape of the non-rigid molten metal during welding, so-called weld pool visual sensing, is one of the central tasks for automating arc welding processes. It is challenging due to the strong interference of the high-intensity arc light and spatters as well as the lack of robust...... approaches to detect and represent the shape of the nonrigid weld pool. We propose a solution using active contours including an prior for the weld pool boundary composition. Also, we apply Adaboost to select a small set of features that captures the relevant information. The proposed method is applied...... to weld pool tracking and the presented results verified its feasibility....

  11. Immobilization of radioactive waste sludge from spent fuel storage pool

    International Nuclear Information System (INIS)

    Pavlovic, R.; Plecas, I.

    1998-01-01

    In the last forty years, in FR Yugoslavia, as result of the research reactors' operation and radionuclides application in medicine, industry and agriculture, radioactive waste materials of the different categories and various levels of specific activities were generated. As a temporary solution, these radioactive waste materials are stored in the two hanger type interim storages for solid waste and some type of liquid waste packed in plastic barrels, and one of three stainless steal underground containers for other types of liquid waste. Spent fuel elements from nuclear reactors in the Vinca Institute have been temporary stored in water filled storage pool. Due to the fact that the water in the spent fuel elements storage pool have not been purified for a long time, all metallic components submerged in the water have been hardly corroded and significant amount of the sludge has been settled on the bottom of the pool. As a first step in improving spent fuel elements storage conditions and slowing down corrosion in the storage spent fuel elements pool we have decided to remove the sludge from the bottom of the pool. Although not high, but slightly radioactive, this sludge had to be treated as radioactive waste material. Some aspects of immobilisation, conditioning and storage of this sludge are presented in this paper. (author

  12. An accurate clone-based haplotyping method by overlapping pool sequencing.

    Science.gov (United States)

    Li, Cheng; Cao, Changchang; Tu, Jing; Sun, Xiao

    2016-07-08

    Chromosome-long haplotyping of human genomes is important to identify genetic variants with differing gene expression, in human evolution studies, clinical diagnosis, and other biological and medical fields. Although several methods have realized haplotyping based on sequencing technologies or population statistics, accuracy and cost are factors that prohibit their wide use. Borrowing ideas from group testing theories, we proposed a clone-based haplotyping method by overlapping pool sequencing. The clones from a single individual were pooled combinatorially and then sequenced. According to the distinct pooling pattern for each clone in the overlapping pool sequencing, alleles for the recovered variants could be assigned to their original clones precisely. Subsequently, the clone sequences could be reconstructed by linking these alleles accordingly and assembling them into haplotypes with high accuracy. To verify the utility of our method, we constructed 130 110 clones in silico for the individual NA12878 and simulated the pooling and sequencing process. Ultimately, 99.9% of variants on chromosome 1 that were covered by clones from both parental chromosomes were recovered correctly, and 112 haplotype contigs were assembled with an N50 length of 3.4 Mb and no switch errors. A comparison with current clone-based haplotyping methods indicated our method was more accurate. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  13. Analysis of natural convection in volumetrically-heated melt pools

    International Nuclear Information System (INIS)

    Sehgal, B.R.; Dinh, T.N.; Nourgaliev, R.R.

    1996-12-01

    Results of series of studies on natural convection heat transfer in decay-heated core melt pools which form in a reactor lower plenum during the progression of a core meltdown accident are described. The emphasis is on modelling and prediction of turbulent heat transfer characteristics of natural convection in a liquid pool with an internal energy source. Methods of computational fluid dynamics, including direct numerical simulation, were applied for investigation

  14. Sodium-water reaction in double pool LMFBR, (5)

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Kumagai, Hiromichi; Nishi, Yoshihisa; Uotani, Masaki

    1990-01-01

    Experiments were conducted using a 1/5 scale model of the Double Pool in order to evaluate a pressure rise caused by a large scale sodium-water reaction. The experiments were focused on the pressure rise caused by the piston motion of liquid sodium. It appeared from the results that the magnitude of this pressure rise depends on the depth of reaction point, and that a pressure rise more than 1 MPa would arise in the real Double Pool plant. A new design of steam generator is proposed to mitigate the pressure rise. (author)

  15. Chemical Safety Alert: Safe Storage and Handling of Swimming Pool Chemicals

    Science.gov (United States)

    Hazards of pool water treatment and maintenance chemicals (e.g., chlorine), and the protective measures pool owners should take to prevent fires, toxic vapor releases, and injuries. Triggered by improper wetting, mixing, or self-reactivity over time.

  16. Laboratory studies on the effect of ozonation on THM formation in swimming pool water

    DEFF Research Database (Denmark)

    Hansen, Kamilla Marie Speht; Spiliotopoulou, Aikaterini; Cheema, Waqas Akram

    2015-01-01

    Water samples from indoor swimming pool were ozonated at different pH values to evaluate the effect of pH on decomposition of ozone in swimming pool water. Furthermore, drinking and pool water were repeatedly ozonated followed by chlorination to evaluate THM formation. Decomposition of ozone...... was not affected by pH in the range relevant to swimming pools (pH 6.8 – 7.8) and a half-life time at 10-12 min was obtained. Repeating the ozonation, the decomposition of ozone increased at the second dose of ozone added (t½,2=8 min) and then decreased again at the third and fourth dose of ozone (t½,3=17 min; t...... chlorine for drinking water as lower TTHM formation occurred than in non-ozonated samples. For pool water, a higher TTHM formation was observed in ozonated than non-ozonated pool water. Thus, it was observed that ozone reacts markedly different in swimming pool water from the known pattern in drinking...

  17. Investigation of pool thermal hydraulics and temperature distribution in inner vessel under mechanical seal leakage

    International Nuclear Information System (INIS)

    Abraham, Juby; Velusamy, K.; Selvaraj, P.

    2015-01-01

    The primary heat sink of prototype fast breeder reactor is a sodium pool which is partitioned into cold pool and hot pool. The inner vessel which separates the cold and hot pools is having penetrations for intermediate heat exchangers. The hot sodium from hot pool leaks into the cold pool through these penetrations and to reduce the leakage, mechanical seals are provided. Leakage of hot sodium into cold pool can lead to thermal stratification in the cold pool and also will affect the temperature distribution in inner vessel. 3-D CFD studies were performed focusing these features as a function of sodium leakage. The analyses indicate that the maximum temperature difference across the IV thickness is 65°C without any leakage of sodium. The temperature difference is found to decrease with increase in leakage through the seals. It is seen that a leakage of 2.5% is acceptable. (author)

  18. Sodium pool fire model for CONACS code

    International Nuclear Information System (INIS)

    Yung, S.C.

    1982-01-01

    The modeling of sodium pool fires constitutes an important ingredient in conducting LMFBR accident analysis. Such modeling capability has recently come under scrutiny at Westinghouse Hanford Company (WHC) within the context of developing CONACS, the Containment Analysis Code System. One of the efforts in the CONACS program is to model various combustion processes anticipated to occur during postulated accident paths. This effort includes the selection or modification of an existing model and development of a new model if it clearly contributes to the program purpose. As part of this effort, a new sodium pool fire model has been developed that is directed at removing some of the deficiencies in the existing models, such as SOFIRE-II and FEUNA

  19. Pricing Electricity in Pools With Wind Producers

    DEFF Research Database (Denmark)

    Morales González, Juan Miguel; Conejo, A. J.; Kai Liu

    2012-01-01

    This paper considers an electricity pool that includes a significant number of wind producers and is cleared through a network-constrained auction, one day in advance and on an hourly basis. The hourly auction is formulated as a two-stage stochastic programming problem, where the first stage...... represents the clearing of the market and the second stage models the system operation under a number of plausible wind production realizations. This formulation co-optimizes energy and reserve, and allows deriving both pool energy prices and balancing energy prices. These prices result in both cost recovery...... for producers and revenue reconciliation. A case study of realistic size is used to illustrate the functioning of the proposed pricing scheme....

  20. Spectrum pooling in MnWave Networks

    DEFF Research Database (Denmark)

    Boccardi, Federico; Shokri-Ghadikolaei, Hossein; Fodor, Gabor

    2016-01-01

    Motivated by the specific characteristics of mmWave technologies, we discuss the possibility of an authorization regime that allows spectrum sharing between multiple operators, also referred to as spectrum pooling. In particular, considering user rate as the performance measure, we assess...

  1. Influence of the arc plasma parameters on the weld pool profile in TIG welding

    Science.gov (United States)

    Toropchin, A.; Frolov, V.; Pipa, A. V.; Kozakov, R.; Uhrlandt, D.

    2014-11-01

    Magneto-hydrodynamic simulations of the arc and fluid simulations of the weld pool can be beneficial in the analysis and further development of arc welding processes and welding machines. However, the appropriate coupling of arc and weld pool simulations needs further improvement. The tungsten inert gas (TIG) welding process is investigated by simulations including the weld pool. Experiments with optical diagnostics are used for the validation. A coupled computational model of the arc and the weld pool is developed using the software ANSYS CFX. The weld pool model considers the forces acting on the motion of the melt inside and on the surface of the pool, such as Marangoni, drag, electromagnetic forces and buoyancy. The experimental work includes analysis of cross-sections of the workpieces, highspeed video images and spectroscopic measurements. Experiments and calculations have been performed for various currents, distances between electrode and workpiece and nozzle diameters. The studies show the significant impact of material properties like surface tension dependence on temperature as well as of the arc structure on the weld pool behaviour and finally the weld seam depth. The experimental weld pool profiles and plasma temperatures are in good agreement with computational results.

  2. Influence of the arc plasma parameters on the weld pool profile in TIG welding

    International Nuclear Information System (INIS)

    Toropchin, A; Frolov, V; Pipa, A V; Kozakov, R; Uhrlandt, D

    2014-01-01

    Magneto-hydrodynamic simulations of the arc and fluid simulations of the weld pool can be beneficial in the analysis and further development of arc welding processes and welding machines. However, the appropriate coupling of arc and weld pool simulations needs further improvement. The tungsten inert gas (TIG) welding process is investigated by simulations including the weld pool. Experiments with optical diagnostics are used for the validation. A coupled computational model of the arc and the weld pool is developed using the software ANSYS CFX. The weld pool model considers the forces acting on the motion of the melt inside and on the surface of the pool, such as Marangoni, drag, electromagnetic forces and buoyancy. The experimental work includes analysis of cross-sections of the workpieces, highspeed video images and spectroscopic measurements. Experiments and calculations have been performed for various currents, distances between electrode and workpiece and nozzle diameters. The studies show the significant impact of material properties like surface tension dependence on temperature as well as of the arc structure on the weld pool behaviour and finally the weld seam depth. The experimental weld pool profiles and plasma temperatures are in good agreement with computational results

  3. EP BICYCLE POOL - VIGNETTES 2002

    CERN Multimedia

    EP-SMI Help Desk

    2002-01-01

    The vignettes (insurance certificates) for 2002 become obligatory from 1 June. If you have a bicycle from the EP Pool, please bring it to the EP-SMI Help Desk (Building 124) on any working day up to 31 May between 8h.30 - 12h.00 or 13h.30 - 17h.30. EP-SMI Help Desk

  4. Southern Africa power pool : benefits, achievements, challenges and sustainability

    International Nuclear Information System (INIS)

    Anderson, G.O.; Opok, A.O.

    2008-01-01

    An overview of the Southern Africa Power Pool (SAPP) was presented. The SAPP was formed by 12 southern African developing countries as a means of minimizing electricity costs and maintaining reliability. The pool includes over 200 million people in a region of 9 million square meters. The SAPP relies on long-term bilateral contracts for electricity supply between customers and generators. The contracts are supplemented by short-term contracts in the short-term energy market. The pool uses a pricing mechanism with 13 detailed schedules dealing with firm power contracts of varying duration; non-firm power contracts of varying duration; mutual support contracts and emergency energy and control area services; scheduled outage energy; and energy banking. Benefits of the pool include reductions or postponements in generating capacity, reserves and fuel costs. New major initiatives planned by the SAPP include increasing interconnection points, the construction of new transmission lines, and the formulation of regional environmental studies. SAPP is now making plans to increase rural electrification in its membership countries with funding from an electricity levy. It was concluded that political and economic co-operation between member states has resulted in the sustained supply of energy in the region. 10 refs., 7 tabs., 3 figs

  5. Odonata (Insecta at a wadi Pool near Nizwa, northern Oman

    Directory of Open Access Journals (Sweden)

    Elaine M. Cowan

    2015-07-01

    Full Text Available Fourteen damselfly and dragonfly species were recorded in 68 visits to a wadi pool in northern Oman, March 2012 to June 2014.  All identifications were based on photographs.  Apparently the pool has a core community of eight resident species.  Paragomphus sinaiticus, globally Near Threatened, was regularly  recorded. 

  6. Statistical evaluation of steam condensation loads in pressure suppression pool, (1)

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Takeshita, Isao; Namatame, Ken; Shiba, Masayoshi; Kato, Masami; Moriya, Kumiaki.

    1981-10-01

    The LOCA steam condensation loads in the BWR pressure suppression pool was evaluated with use of the test data obtained in the first eight tests of the JAERI Full-Scale Mark II CRT Program. Through this evaluation, finite desynchronization between the vent pressures during the chugging and the condensation oscillation phases was identified and quantified. The characteristics of the pressure oscillation propagation through the vent pipe and in the pool water, the fluid-structure-interaction (FSI) effects on the pool pressure loads, and the characteristics of the vent lateral loads were also investigated. (author)

  7. Swimming pool attendance and respiratory symptoms and allergies among Dutch children

    NARCIS (Netherlands)

    Jacobs, J.H.; Fuertes, E.; Krop, E.J.M.; Spithoven, J.; Tromp, P.; Heederik, D.J.J.

    2012-01-01

    OBJECTIVES To describe associations among swimming, respiratory health, allergen sensitisation and Clara cell protein 16 (CC16) levels in Dutch schoolchildren. Trichloramine levels in swimming pool air were determined to assess potential exposure levels. METHODS Respiratory health and pool

  8. Modeling of condensation, stratification, and mixing phenomena in a pool of water

    Energy Technology Data Exchange (ETDEWEB)

    Li, H.; Kudinov, P.; Villanueva, W. (Royal Institute of Technology (KTH). Div. of Nuclear Power Safety, Stockholm (Sweden))

    2010-12-15

    This work pertains to the research program on Containment Thermal-Hydraulics at KTH. The objective is to evaluate and improve performance of methods, which are used to analyze thermal-hydraulics of steam suppression pools in a BWR plant under different abnormal transient and accident conditions. As a passive safety system, the function of steam pressure suppression pools is paramount to the containment performance. In the present work, the focus is on apparently-benign but intricate and potentially risk-significant scenarios in which thermal stratification could significantly impede the pool's pressure suppression capacity. For the case of small flow rates of steam influx, the steam condenses rapidly in the pool and the hot condensate rises in a narrow plume above the steam injection plane and spreads into a thin layer at the pool's free surface. When the steam flow rate increases significantly, momentum introduced by the steam injection and/or periodic expansion and shrink of large steam bubbles due to direct contact condensation can cause breakdown of the stratified layers and lead to mixing of the pool water. Accurate prediction of the pool thermal-hydraulics in such scenarios presents a computational challenge. Lumped-parameter models have no capability to predict temperature distribution of water pool during thermal stratification development. While high-order-accurate CFD (RANS, LES) methods are not practical due to excessive computing power needed to calculate 3D high-Rayleighnumber natural circulation flow in long transients. In the present work, a middleground approach is used, namely CFD-like model of the general purpose thermalhydraulic code GOTHIC. Each cell of 3D GOTHIC grid uses lumped parameter volume type closures for modeling of various heat and mass transfer processes at subgrid scale. We use GOTHIC to simulate POOLEX/PPOOLEX experiment, in order to (a) quantify errors due to GOTHIC's physical models and numerical schemes, and (b

  9. Designing ARVs Patent Pool Up to Trade & Policy Evolutionary Dynamics.

    Science.gov (United States)

    Dionisio, Daniele; Racalbuto, Vincenzo; Messeri, Daniela

    2010-01-19

    Patent pools for second and third-line Fixed Dose Combination (FDC) antiretroviral drugs (ARVs) should not be delayed as they are instrumental to urgent public health needs in the under-served markets.Nonetheless, multinational originator companies still seem to perceive patent pooling for ARVs as a minefield that would offer the generic competitors lots of deeply exploitable opportunities, to the detriment of patent owner's rights.This paper analyses the brand industry concerns, while looking for a strategy up to a really equitable and free world market, without any discrimination between end-users in wealthy and resource-limited countries.This strategy would urge partnerships between originator companies first to make newer FDC ARVs quickly available and allow patent pool agreements with generic counterparts to be negotiated straight afterwards.The patent pool strategy highlighted in this paper would assert the primacy of health over for-profit policies, while aligning with the 61(st) WHO's Assembly recommendations and G7, G8 and World Trade Organisation's warnings and pledges against trade protectionism.

  10. Analysis of natural convection in volumetrically-heated melt pools

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R.; Dinh, T.N.; Nourgaliev, R.R. [Royal Inst. of Tech., Stockholm (Sweden). Div. of Nuclear Power Safety

    1996-12-01

    Results of series of studies on natural convection heat transfer in decay-heated core melt pools which form in a reactor lower plenum during the progression of a core meltdown accident are described. The emphasis is on modelling and prediction of turbulent heat transfer characteristics of natural convection in a liquid pool with an internal energy source. Methods of computational fluid dynamics, including direct numerical simulation, were applied for investigation. Refs, figs, tabs.

  11. Standardized Total Average Toxicity Score: A Scale- and Grade-Independent Measure of Late Radiotherapy Toxicity to Facilitate Pooling of Data From Different Studies

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, Gillian C., E-mail: gillbarnett@doctors.org.uk [University of Cambridge Department of Oncology, Oncology Centre, Cambridge (United Kingdom); Cancer Research-UK Centre for Genetic Epidemiology and Department of Oncology, Strangeways Research Laboratories, Cambridge (United Kingdom); West, Catharine M.L. [School of Cancer and Enabling Sciences, Manchester Academic Health Science Centre, University of Manchester, Christie Hospital, Manchester (United Kingdom); Coles, Charlotte E. [University of Cambridge Department of Oncology, Oncology Centre, Cambridge (United Kingdom); Pharoah, Paul D.P. [Cancer Research-UK Centre for Genetic Epidemiology and Department of Oncology, Strangeways Research Laboratories, Cambridge (United Kingdom); Talbot, Christopher J. [Department of Genetics, University of Leicester, Leicester (United Kingdom); Elliott, Rebecca M. [School of Cancer and Enabling Sciences, Manchester Academic Health Science Centre, University of Manchester, Christie Hospital, Manchester (United Kingdom); Tanteles, George A. [Department of Clinical Genetics, University Hospitals of Leicester, Leicester (United Kingdom); Symonds, R. Paul [Department of Cancer Studies and Molecular Medicine, University Hospitals of Leicester, Leicester (United Kingdom); Wilkinson, Jennifer S. [University of Cambridge Department of Oncology, Oncology Centre, Cambridge (United Kingdom); Dunning, Alison M. [Cancer Research-UK Centre for Genetic Epidemiology and Department of Oncology, Strangeways Research Laboratories, Cambridge (United Kingdom); Burnet, Neil G. [University of Cambridge Department of Oncology, Oncology Centre, Cambridge (United Kingdom); Bentzen, Soren M. [University of Wisconsin, School of Medicine and Public Health, Department of Human Oncology, Madison, WI (United States)

    2012-03-01

    Purpose: The search for clinical and biologic biomarkers associated with late radiotherapy toxicity is hindered by the use of multiple and different endpoints from a variety of scoring systems, hampering comparisons across studies and pooling of data. We propose a novel metric, the Standardized Total Average Toxicity (STAT) score, to try to overcome these difficulties. Methods and Materials: STAT scores were derived for 1010 patients from the Cambridge breast intensity-modulated radiotherapy trial and 493 women from University Hospitals of Leicester. The sensitivity of the STAT score to detect differences between patient groups, stratified by factors known to influence late toxicity, was compared with that of individual endpoints. Analysis of residuals was used to quantify the effect of these covariates. Results: In the Cambridge cohort, STAT scores detected differences (p < 0.00005) between patients attributable to breast volume, surgical specimen weight, dosimetry, acute toxicity, radiation boost to tumor bed, postoperative infection, and smoking (p < 0.0002), with no loss of sensitivity over individual toxicity endpoints. Diabetes (p = 0.017), poor postoperative surgical cosmesis (p = 0.0036), use of chemotherapy (p = 0.0054), and increasing age (p = 0.041) were also associated with increased STAT score. When the Cambridge and Leicester datasets were combined, STAT was associated with smoking status (p < 0.00005), diabetes (p = 0.041), chemotherapy (p = 0.0008), and radiotherapy boost (p = 0.0001). STAT was independent of the toxicity scale used and was able to deal with missing data. There were correlations between residuals of the STAT score obtained using different toxicity scales (r > 0.86, p < 0.00005 for both datasets). Conclusions: The STAT score may be used to facilitate the analysis of overall late radiation toxicity, from multiple trials or centers, in studies of possible genetic and nongenetic determinants of radiotherapy toxicity.

  12. Representation of a common 3-pool compartment model for N turnover of ruminants

    International Nuclear Information System (INIS)

    Ulbrich, M.

    1989-01-01

    On the basis of an existing 3-pool compartment model for the N turnover of lactating ruminants a method was elaborated for N turnover determination in non-lactating ruminants by measuring the 15 N frequency in NPN pool and without experimental measurements of the 15 N frequency in the amino acid pool

  13. Atlantic Warm Pool Trigger for the Younger Dryas Climate Event

    Science.gov (United States)

    Abdul, N. A.; Mortlock, R. A.; Wright, J. D.; Fairbanks, R. G.; Teneva, L. T.

    2011-12-01

    There is growing evidence that variability in the size and heat content of the tropical Atlantic Warm Pool impacts circum-North Atlantic climate via the Atlantic Multi-decadal Oscillation mode (Wang et al., 2008). The Atlantic Warm Pool spans the Gulf of Mexico, Caribbean Sea and the western tropical North Atlantic. Barbados is located near the center of the tropical Atlantic Warm Pool and coupled ocean models suggest that Barbados remains near the center of the tropical Atlantic Warm Pool under varying wind stress simulations. Measurements of the oxygen isotope paleothermometer in Acropora palmata coral species recovered from cores offshore Barbados, show a 3oC monotonic decrease in sea surface temperature from 13106 ± 83 to 12744 ± 61 years before present (errors given as 2 sigma). This interval corresponds to a sea level rise from 71.4 meters to 67.1 meters below present levels at Barbados. The 3oC temperature decrease is captured in eight A. palmata specimens that are in stratigraphic sequence, 230Th/234U dated, and analyzed for oxygen isotopes. All measurements are replicated. We are confident that this is the warm pool equivalent of the Younger Dryas climate event. The initiation of this temperature drop in the Atlantic Warm Pool predates the Younger Dryas start in Greenland ice cores, reported to start at 12896 ± 138 years (relative to AD 2000) (Rasmussen et al., 2006), while few other Younger Dryas climate records are dated with similar accuracy to make the comparison. Rasmussen, S.O., Andersen, K.K., Svensson, A.M., Steffensen, J.P., Vinther, B.M., Clausen, H.B., Siggaard-Andersen, M.L., Johnsen, S.J., Larsen, L.B., Dahl-Jensen, D., Bigler, M., Röthlisberger, R., Fischer, H., Goto-Azuma, K., Hansson, M.E., and Ruth, U., 2006, A new Greenland ice core chronology for the last glacial termination: J. Geophys. Res., v. 111, p. D06102. Wang, C., Lee, S.-K., and Enfield, D.B., 2008, Atlantic Warm Pool acting as a link between Atlantic Multidecadal

  14. Antibody screening by enzyme-linked immunosorbent assay using pooled soluble HLA in renal transplant candidates.

    Science.gov (United States)

    Zaer, F; Metz, S; Scornik, J C

    1997-01-15

    The enzyme-linked immunosorbent assay (ELISA) using HLA class I molecules purified from pooled platelets has the potential to detect HLA antibodies with increased efficiency without sacrificing sensitivity or specificity. This test, which was originally developed in our institution, has been independently validated by recent studies and is now commercially available. We now present evidence of its usefulness as a routine HLA antibody screening test for renal transplant patients. A total of 515 patients were tested monthly by ELISA (13.9 tests/patient) and by antiglobulin-enhanced panel reactivity (6.3 tests/patient). In patients found to be unsensitized, the incidence of false-positive results was less for ELISA than for the panel studies. In patients who were highly sensitized, both tests performed equally well, whereas discordant results were registered mainly in cases of mild sensitization. Because 66% of our patients were not sensitized, the ELISA was effective in reducing the number of more involved tests aimed at characterizing the antibodies. These results provide a foundation to use the pooled platelet HLA ELISA on a routine basis for HLA antibody screening.

  15. Removal of volatile iodine from gas bubbles rising in water pools: review and assessment of pool scrubbing codes

    International Nuclear Information System (INIS)

    Polo, J.; Herranz, L.E.; Peyres, V.; Escudero, M.

    1996-01-01

    During a hypothetical nuclear reactor accident with core damage the fission products released from the degrading fuel bundles often pass through aqueous beds before entering the containment, mitigating in part the source term. Several computer codes have been developed for predicting the fission product and aerosols removal in pool scrubbing scenarios. In addition to particle removal, these codes simulate the retention of some volatile iodine compounds. Nonetheless, experimental data on the matter are rather scarce and further validation remains to be done. In this work a review of volatile iodine removal models included in SPARC and BUSCA codes is presented. Besides, the results and discussions of a validation of both codes against the available experimental data are summarized. SPARC and BUSCA codes model the diffusion of iodine toward the bubble interface by using the film penetration theory, which assumes a double layer gas-liquid at the interface. However, there are some differences between the two models, mainly related to the boundary conditions in the aqueous volume for the diffusion of molecular iodine. In SPARC, a set of fast reactions in the liquid phase control both the molecular iodine concentration in the pool and the partition coefficient of iodine at the interface. Thus, the aqueous chemistry plays an important role in the boundary conditions for the diffusion process. On the contrary, the BUSCA model has no chemical considerations at all, and assumes a null iodine concentration in the water bulk. Several sensitivity studies have been made in order to weight the effect of these differences. The variables examined in these studies were the pool temperature and the incoming iodine concentration in the pool. Additionally, sensitivity studies focused on the steam mass fraction of the injected gas were performed to study the effect of the different approach of both models for the condensation process. The results showed a different sensitivity of SPARC

  16. Volume-heated boiling pool flow behavior and application to transition phase accident conditions

    International Nuclear Information System (INIS)

    Ginsberg, T.; Jones, O.C. Jr.; Chen, J.C.

    1978-01-01

    Observations of two-phase flow fields in volume-heated boiling pools are reported. Photographic observations, together with pool-average void fraction measurements are presented. Flow regime transition criteria derived from the measurements are discussed. The churn-turbulent flow regime was the dominant regime for superficial vapor velocities up to nearly five times the Kutateladze dispersal velocity. Within this range of conditions, a churn-turbulent drift flux model provides a reasonable prediction of the pool-average void fraction data. The results of the experiment and analyses are extrapolated to transition phase conditions. It is shown that intense pool boil-up could occur where the pool-average void fraction would be greater than 0.6 for steel vaporization rates equivalent to power levels greater than one percent of nominal LMFBR power density

  17. Mixed convection and stratification phenomena in a heavy liquid metal pool

    Energy Technology Data Exchange (ETDEWEB)

    Tarantino, Mariano, E-mail: mariano.tarantino@enea.it [Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone (Italy); Martelli, Daniele; Barone, Gianluca [Dipartimento di Ingegneria Civile e Industriale, University of Pisa, Largo Lucio Lazzarino, 1-56100 Pisa Italy (Italy); Di Piazza, Ivan [Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone (Italy); Forgione, Nicola [Dipartimento di Ingegneria Civile e Industriale, University of Pisa, Largo Lucio Lazzarino, 1-56100 Pisa Italy (Italy)

    2015-05-15

    Highlights: • Results related to experiments reproducing PLOHS + LOF accident in CIRCE pool facility. • Vertical thermal stratification in large HLM pool. • Transition from forced to natural circulation in HLM pool under DHR conditions. • Heat transfer coefficient measurement in HLM pin bundle. • Nusselt numbers calculations and comparison with correlations. - Abstract: This work deals with an analysis of the first experimental series of tests performed to investigate mixed convection and stratification phenomena in CIRCE HLM large pool. In particular, the tests concern the transition from nominal flow to natural circulation regime, typical of decay heat removal (DHR) regime. To this purpose the CIRCE pool facility has been updated to host a suitable test section in order to reproduce the thermal-hydraulic behaviour of a HLM pool-type reactor. The test section basically consists of an electrical bundle (FPS) made up of 37 pins arranged in a hexagonal wrapped lattice with a pitch diameter ratio of 1.8. Along the FPS active length, three sections were instrumented to monitor the heat transfer coefficient along the bundle as well as the cladding temperatures at different ranks of the sub-channels. This paper reports the experimental data as well as a preliminary analysis and discussion of the results, focusing on the most relevant tests of the campaign, namely Test I (48 h) and Test II (97 h). Temperatures along three sections of the FPS and at inlet and outlet sections of the main components were reported and the Nusselt number in the FPS sub-channels was investigated together with the void fraction in the riser. Concerning the investigation of in-pool thermal stratification phenomena, the temperatures in the whole LBE pool were monitored at different elevations and radial locations. The analysis of experimental data obtained from Tests I and II underline the occurrence of thermal stratification phenomena in the region placed between the outlet sections of

  18. Velocity Fields Measurement of Natural Circulation Flow inside a Pool Using PIV Technique

    International Nuclear Information System (INIS)

    Kim, Seok; Kim, Dong Eok; Youn, Young Jung; Euh, Dong Jin; Song, Chul Hwa

    2012-01-01

    Thermal stratification is encountered in large pool of water increasingly being used as heat sink in new generation of advanced reactors. These large pools at near atmospheric pressure provide a heat sink for heat removal from the reactor or steam generator, and the containment by natural circulation as well as a source of water for core cooling. For examples, the PAFS (passive auxiliary feedwater system) is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor Plus), which is intended to completely replace the conventional active auxiliary feedwater system. The PAFS cools down the steam generator secondary side and eventually removes the decay heat from the reactor core by adopting a natural convection mechanism. In a pool, the heat transfer from the PCHX (passive condensation heat exchanger) contributed to increase the pool temperature up to the saturation condition and induce the natural circulation flow of the PCCT (passive condensate cooling tank) pool water. When a heat rod is placed horizontally in a pool of water, the fluid adjacent to the heat rod gets heated up. In the process, its density reduces and by virtue of the buoyancy force, the fluid in this region moves up. After reaching the top free surface, the heated water moves towards the other side wall of the pool along the free surface. Since this heated water is cooling, it goes downward along the wall at the other side wall. Above heater rod, a natural circulation flow is formed. However, there is no flow below heater rod until pool water temperature increases to saturation temperature. In this study, velocity measurement was conducted to reveal a natural circulation flow structure in a small pool using PIV (particle image velocimetry) measurement technique

  19. Breeding Birds Associated with Seasonal Pools in the Northeastern United States

    Science.gov (United States)

    Seasonal pools in the northeast US are important habitats for amphibians and invertebrates, but little is known of their importance for birds. We examined avian community composition at seasonal pools across an urbanization gradient in Rhode Island to test the hypotheses that se...

  20. Controls on the size and occurrence of pools in coarse-grained forest rivers

    Science.gov (United States)

    John M. Buffington; Thomas E. Lisle; Richard D. Woodsmith; Sue Hilton

    2002-01-01

    Controls on pool formation are examined in gravel- and cobble-bed rivers in forest mountain drainage basins of northern California, southern Oregon, and southeastern Alaska. We demonstrate that the majority of pools at our study sites are formed by flow obstructions and that pool geometry and frequency largely depend on obstruction characteristics (size, type, and...

  1. 33 CFR 207.60 - Federal Dam, Hudson River, Troy, N.Y.; pool level.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Federal Dam, Hudson River, Troy, N.Y.; pool level. 207.60 Section 207.60 Navigation and Navigable Waters CORPS OF ENGINEERS..., N.Y.; pool level. (a) Whenever the elevation of the pool created by the Federal dam at Troy, N.Y...

  2. Automation of water supply and recirculation-filtration of water at a swimming pool using Zelio PLC

    Science.gov (United States)

    Diniş, C. M.; Popa, G. N.; Iagăr, A.

    2018-01-01

    The paper proposes the use of the Zelio PLC for the automation of the water supply and recirculation-filtration system of a swimming pool. To do this, the Zelio SR3B261BD - 24V DC with 10 digital inputs (24V DC) and 10 digital outputs (relay contacts) was used. The proposed application makes the control of the water supply pumps and the water recirculation-filtration from a swimming pool. The recirculation-filtration systems for pools and swimming pools are designed to ensure water cleaning and recirculation to achieve optimum quality and lasting service life. The water filtration process is one of the important steps in water treatment in polls and swimming pools. It consists in recirculation of the entire volume of water and begins by absorbing the water in the pool by means of a pump followed by the passing of water through the filter, disinfectant and pH dosing, and reintroducing the water back into the pool or swimming pool through the discharge holes. Filters must to work 24 hours a day to remove pollutants from pools or swimming pools users. Filtration removes suspension particles with different origins. All newly built pools and swimming pools must be fitted with water recirculation systems, and existing ones will be equipped with water recirculation and water treatment systems.

  3. Pool-type reactor

    International Nuclear Information System (INIS)

    Hopkins, S.R.

    1977-01-01

    This invention relates to a pool nuclear reactor fitted with a perfected system to raise the buckets into a vertical position at the bottom of a channel. This reactor has an inclined channel to guide a bucket containing a fuel assembly to introduce it into the reactor jacket or extract it therefrom and a damper at the bottom of the channel to stop the drop of the bucket. An upright vertically movable rod has a horizontally articulated arm with a hook. This can pivot to touch a radial lug on the bucket and pivot the bucket around its base in a vertical position, when the rod moves up [fr

  4. Indacaterol/glycopyrronium in symptomatic patients with COPD (GOLD B and GOLD D versus salmeterol/fluticasone: ILLUMINATE/LANTERN pooled analysis

    Directory of Open Access Journals (Sweden)

    Vogelmeier C

    2016-12-01

    Full Text Available Claus Vogelmeier,1 Nanshan Zhong,2 Michael J Humphries,3 Karen Mezzi,4 Robert Fogel,5 Giovanni Bader,4 Francesco Patalano,4 Donald Banerji5 1Department of Medicine, Pulmonary and Critical Care Medicine, University Medical Center Giessen and Marburg, Philipps-University Marburg, Member of the German Center for Lung Research (DZL, Marburg, Germany; 2State Key Laboratory, Guangzhou Institute of Respiratory Diseases, First Affiliated Hospital, Guangzhou Medical University, Guangzhou, 3Beijing Novartis Pharma Co. Ltd., Shanghai, People’s Republic of China; 4Novartis Pharma AG, Basel, Switzerland; 5Novartis Pharmaceuticals Corporation, East Hanover, NJ, USA Background: Indacaterol/glycopyrronium (IND/GLY is approved for maintenance treatment of adult patients with COPD. This post hoc analysis explored the efficacy and safety of IND/GLY versus salmeterol/fluticasone (SFC in symptomatic (Global Initiative for Chronic Obstructive Lung Disease [GOLD] B and GOLD D patients with moderate-to-severe COPD.Patients and methods: Data from LANTERN and ILLUMINATE studies were pooled and analyzed. In both studies, symptomatic COPD patients were randomized to once-daily IND/GLY 110 µg/50 µg or twice-daily SFC 50 µg/500 µg. End points were pre-dose trough forced expiratory volume in one second (FEV1, standardized area under the curve for FEV1 from 0 to 12 hours (FEV1 AUC0–12 hours, peak FEV1, peak forced vital capacity (FVC, pre-dose trough FVC, Transition Dyspnea Index (TDI total score, St George’s Respiratory Questionnaire total score, rescue medication use and safety.Results: A total of 1,263 patients were classified as either GOLD B (n=809 or GOLD D (n=454. At week 26, IND/GLY demonstrated statistically significant improvement in all lung function parameters versus SFC in patients in both the GOLD B and GOLD D subgroups. TDI total score and rescue medication use were significantly improved with IND/GLY versus SFC in the overall population and in the

  5. Mark II pressure suppression containment systems: an analytical model of the pool swell phenomenon

    International Nuclear Information System (INIS)

    Ernst, R.J.; Ward, M.G.

    1976-12-01

    A one-dimensional pool swell model of the dynamic and thermodynamic conditions in the suppression chamber following a postulated loss-of-coolant accident (LOCA) is described. The pool swell phenomena is approximated by a constant thickness water slug, which is accelerated upward by the difference between the air bubble pressure acting below the pool and the wetwell air space pressure acting above the pool surface. The transient bubble pressure is computed using the known drywell pressure history and a quasi-steady compressible vent flow model. Comparisons of model predictions with pool swell experimental data are favorable and show the model is based on a conservative interpretation of the physical phenomena involved

  6. The CERN Electronics Pool moves to Building 13

    CERN Multimedia

    PH Department

    2010-01-01

    After 32 years in Building 4 R‐050, the CERN Electronics Pool will re‐open in Building 13 R009 on Monday 13 December at 10:00 As of this date, you will be able to come and choose the instruments you want: oscilloscopes and other measurement instruments, low and high voltage power supplies, modular instrumentation, etc. Please do not hesitate to consult the catalogue and give us any input you may have. The CERN Electronics Pool operates on a self-service basis (with a CERN budget code) and is available for any help you may need.

  7. Optimization of spent fuel pool weir gate driving mechanism

    Science.gov (United States)

    Liu, Chao; Du, Lin; Tao, Xinlei; Wang, Shijie; Shang, Ertao; Yu, Jianjiang

    2018-04-01

    Spent fuel pool is crucial facility for fuel storage and nuclear safety, and the spent fuel pool weir gate is the key related equipment. In order to achieve a goal of more efficient driving force transfer, loading during the opening/closing process is analyzed and an optimized calculation method for dimensions of driving mechanism is proposed. The result of optimizing example shows that the method can be applied to weir gates' design with similar driving mechanism.

  8. 99Tcm-MDP imaging for the diagnosis of joint infection after total hip arthroplasty

    International Nuclear Information System (INIS)

    Li Yuan; Wang Qian; Yue Minggang

    2013-01-01

    Objective: To investigate the value of 99 Tc m -MDP imaging for the differential diagnosis between infection and aseptic loosening after total hip arthroplasty. Methods: During February 2008 to August 2011, 74 patients (32 males, 42 females, average age (64.3±11.2) years) with hip pain after arthroplasty underwent 3-phase (blood flow, blood pool and bone phases) 99 Tc m -MDP imaging. All patients had measurements of serum C reactive protein (CRP) and erythrocyte sedimentation rate (ESR). Joint infection was defined as either increased peri-prosthetic soft tissue activity during perfusion and blood pool phases or increased peri-prosthetic bone activity during uptake phase, or positive in all 3 phases. Aseptic loosening was defined as having negative 99 Tc m -MDP in all 3 phases. Clinical diagnosis was chosen as the gold standard. The blood flow-pool imaging was compared with the serum examinations. χ 2 test was used for statistical analysis. Results: There were 74 symptomatic joints in 74 patients, including 24 joint infections and 50 aseptic loosening. For the detection of peri-prosthetic infection, combined perfusion-blood-pool phase was more accurate than bone uptake phase (90.5% (67/74) vs 55.4% (41/74); χ 2 =23.159, P<0.001), with the sensitivity of 91.7% (22/24) vs 70.8% (17/24) and specificity of 90.0% (45/50) vs 48.0% (24/50), respectively. The blood flow-pool imaging was also more accurate than CRP (73.0% (54/74); χ 2 =7.656, P<0.05) and ESR (71.6% (53/74); χ 2 =8.633, P<0.05), respectively. Conclusion: 99 Tc m -MDP perfusion/blood flow-pool imaging is an accurate modality for differentiating peri-prosthetic infection from aseptic loosening in patients with hip pain after arthroplasty. (authors)

  9. Production and release of {sup 14}C from a swimming pool reactor

    Energy Technology Data Exchange (ETDEWEB)

    Krishnamoorthy, T M [Bhabha Atomic Research Centre, Mumbai (India). Environmental Assessment Div.; Sadarangani, S H [Bhabha Atomic Research Centre, Mumbai (India). Radiation Safety Systems Div.; Doshi, G R [Bhabha Atomic Research Centre, Bombay (India). Health Physics Div.

    1994-04-01

    The annual production rate of {sup 14}C in the Apsara swimming pool reactor works out to be about 2.94 mCi. The concentration distribution of {sup 14}C in different compartments viz. pool water, reactor hall air and ion-exchange resin ranged from 200 to 440 pCi/l, 0.09 to 0.38 pCi/l, an average concentration of 8.16 pCi/g respectively. The mean residence time of {sup 14}C in pool water is evaluated to be about 7 days taking into account various sinks. The study revealed atmospheric exchange at the air-water interface as the dominant process responsible for the loss of {sup 14}C from the pool water. (author). 7 refs., 2 figs., 4 tabs.

  10. Ingestion of swimming pool water by recreational

    Data.gov (United States)

    U.S. Environmental Protection Agency — Swimming pool water ingestion data. This dataset is associated with the following publication: Dufour, A., L. Wymer, M. Magnuson, T. Behymer, and R. Cantu. Ingestion...

  11. Accounting issues: should the merger be treated as purchase or pooling?

    Science.gov (United States)

    Finkler, S A

    1985-05-01

    Under accounting rules, a merger or consolidation can be treated as either a purchase or pooling. A purchase causes an adjustment in the selling hospital's asset basis to fair market value with goodwill often resulting. Such an adjustment is usually favorable for a taxable acquisition but not a tax-free reorganization. A pooling, on the other hand, results in the assets of the two organizations being merged together with no adjustment in asset values or increase in goodwill. The requirements for pooling are strict but the result is the carryover of assets at historical cost, usually favorable for reporting EPS.

  12. A scale model to evaluate water evaporation from indoor swimming pools

    Energy Technology Data Exchange (ETDEWEB)

    Asdrubali, F. [Department of Industrial Engineering, University of Perugia, Via G. Duranti 67, 06125 Perugia (Italy)

    2009-03-15

    The evaluation of water evaporation from indoor swimming pools is a topic of considerable practical interest, since evaporation may cause the highest energy consumption of the pool plant. A purposely designed experimental apparatus was used to measure the water evaporation rate from a pool scale model inserted into a climatic chamber to control environmental conditions. The experimental data were obtained varying various parameters such as water temperature, air temperature, relative humidity and air velocity. The results were used to propose a prediction model for water evaporation which was compared to other methods found in the literature, showing a good agreement. (author)

  13. Seismic analysis and design of spent subassembly storage bay (SSSB) pool

    International Nuclear Information System (INIS)

    Abdul Gani, H.I.; Ramanjaneyulu, K.V.S.; Pillai, C.S.; Chetal, S.C.

    2003-01-01

    Fuel bundles, after their specified stay in reactor core, are replaced by fresh fuel for sustaining power generation at rated levels. The irradiated fuel subassembly, removed fresh from core, known as spent fuel sub assembly, is radioactive and decay heat generating. It needs to be cooled before it becomes amenable for handling, either for reprocessing or for immobilisation. For this purpose, it is immersed in a pool of water, retained in a concrete structure referred as Spent Subassembly Storage Bay (SSSB) pool. The height of water column above fuel bundles is arrived from shielding considerations. SSSB pool is one of the nuclear safety related structures and warrants rigorous analysis and design. The SSSB pool, in case of PFBR 500 MW(e) is located in fuel building. It is a stainless steel lined. water retaining rectangular R.C.C. open tank of size 7.5 X 29.0 m, with a height of 11.0 m. This structure is analysed for two levels of site specific earthquakes taking in to account liquid structure interactions as per ASCE-4, 1998. The design of walls and bottom slab is carried out satisfying the AERB code for nuclear safety related structures. Analysis and design of SSSB pool of PFBR is presented in the following paper. (author)

  14. Cream skimming, dregs skimming, and pooling: On the dynamics of competitive screening

    OpenAIRE

    Lund, Diderik; Nilssen, Tore

    2000-01-01

    We discuss the existence of a pooling equilibrium in a two-period model of an insurance market with asymmetric information. We solve the model numerically. We pay particular attention to the reasons for non-existence in cases where no pooling equilibrium exists. In addition to the phenomenon of cream skimming emphasized in earlier literature, we here point to the importance of the opposite: dregs skimming, whereby high-risk consumers are profitably detracted from the candidate pooling contrac...

  15. Core disruptive accident and recriticality analysis with FX2-POOL

    International Nuclear Information System (INIS)

    Abramson, P.B.

    1976-01-01

    The current state of development of FX2-POOL, a two-dimensional hydrodynamic, thermodynamic and neutronic scoping model for Hypothetical Core Disruptive Accident analysis is described. Checkout comparisons to VENUS for prompt burst conditions were good. Use of FX2-POOL to examine the importance of fuel to steel heat transfer during a prompt burst indicates that heat transfer plays no important role on that time scale. Scoping studies of material thermohydrodynamics for about 20 to 30 milliseconds following the prompt burst indicate that heat transfer is important on the time scale necessary for the CDA bubble to grow to the size of the original core. Preliminary results are presented for energetics of boiling fuel steel pools which are forced recritical by local surface pressurization

  16. Benefits of carbon dioxide as pH reducer in chlorinated indoor swimming pools.

    Science.gov (United States)

    Gomà, Anton; Guisasola, Albert; Tayà, Carlota; Baeza, Juan A; Baeza, Mireia; Bartrolí, Albert; Lafuente, Javier; Bartrolí, Jordi

    2010-06-01

    Carbon dioxide is seldom used as pH reducer in swimming pools. Nevertheless it offers two interesting advantages. First, its use instead of the usual hydrochloric acid avoids the characteristic and serious accident of mixing the disinfectant with that strong acid, which forms a dangerous chlorine gas cloud and, second, it allows the facility to become slightly a depository of that greenhouse gas. This work introduces the experience of using CO(2) as pH reducer in real working swimming pools, showing three more advantages: lower chlorine consumption, lower presence of oxidants in the air above the swimming pool and a diminished formation of trihalomethanes in the swimming pool water. Experiments lasted 4years and they were run in three swimming pools in the Barcelona area, where the conventional system based upon HCl and a system based upon CO(2) were consecutively exchanged.

  17. Theoretical assessment of particle generation from sodium pool fires

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, M., E-mail: monica.gmartin@ciemat.es [CIEMAT, Unit of Nuclear Safety Research, Av. Complutense, 40, 28040 Madrid (Spain); Herranz, L.E., E-mail: luisen.herranz@ciemat.es [CIEMAT, Unit of Nuclear Safety Research, Av. Complutense, 40, 28040 Madrid (Spain); Kissane, M.P., E-mail: Martin.KISSANE@oecd.org [Nuclear Safety Technology and Regulation Division, OECD Nuclear Energy Agency (NEA), 46 quai Alphonse Le Gallo, 92100 Boulogne-Billancourt (France)

    2016-12-15

    Highlights: • Development of particle generation model for sodium-oxides aerosol formation. • Development of partially validated numerical simulations to build up maps of saturation ratio. • Nucleation of supersaturated vapours as relevant source of aerosols over sodium pools. • Prediction of high concentrations of primary particles in the combustion zone. - Abstract: Potential sodium discharge in the containment during postulated Beyond Design Basis Accidents (BDBAs) in Sodium-cooled Fast Reactors (SFRs) would have major consequences for accident development in terms of energetics and source term. In the containment, sodium vaporization and subsequent oxidation would result in supersaturated oxide vapours that would undergo rapid nucleation creating toxic aerosols. Therefore, modelling this vapour nucleation is essential to proper source term assessment in SFRs. In the frame of the EU-JASMIN project, a particle generation model to calculate the particle generation rate and their primary size during an in-containment sodium pool fire has been developed. Based on a suite of individual models for sodium vaporization, oxygen natural circulation (3D modelling), sodium-oxygen chemical reactions, sodium-oxides-vapour nucleation and condensation, its consistency has been partially validated by comparing with available experimental data. As an outcome, large temperature and vapour concentration gradients set over the sodium pool have been found which result in large particle concentrations in the close vicinity of the pool.

  18. Reactor TRIGA PUSPATI (RTP) spent fuel pool conceptual design

    International Nuclear Information System (INIS)

    Mohd Fazli Zakaria; Tonny Lanyau; Ahmad Nabil Ab Rahim

    2010-01-01

    Reactor TRIGA PUSPATI (RTP) is the one and only research reactor in Malaysia that has been safely operated and maintained since 1982. In order to enhance technical capabilities and competencies especially in nuclear reactor engineering a feasibility study on RTP power upgrading was proposed to serve future needs for advance nuclear science and technology in the country with the capability of designing and develop reactor system. The need of a Spent Fuel Pool begins with the discharge of spent fuel elements from RTP for temporary storage that includes all activities related to the storage of fuel until it is either sent for reprocessed or sent for final disposal. To support RTP power upgrading there will be major RTP systems replacement such as reactor components and a new temporary storage pool for fuel elements. The spent fuel pool is needed for temporarily store the irradiated fuel elements to accommodate a new reactor core structure. Spent fuel management has always been one of the most important stages in the nuclear fuel cycle and considered among the most common problems to all countries with nuclear reactors. The output of this paper will provide sufficient information to show the Spent Fuel Pool can be design and build with the adequate and reasonable safety assurance to support newly upgraded TRIGA PUSPATI TRIGA Research Reactor. (author)

  19. Sparse feature learning for instrument identification: Effects of sampling and pooling methods.

    Science.gov (United States)

    Han, Yoonchang; Lee, Subin; Nam, Juhan; Lee, Kyogu

    2016-05-01

    Feature learning for music applications has recently received considerable attention from many researchers. This paper reports on the sparse feature learning algorithm for musical instrument identification, and in particular, focuses on the effects of the frame sampling techniques for dictionary learning and the pooling methods for feature aggregation. To this end, two frame sampling techniques are examined that are fixed and proportional random sampling. Furthermore, the effect of using onset frame was analyzed for both of proposed sampling methods. Regarding summarization of the feature activation, a standard deviation pooling method is used and compared with the commonly used max- and average-pooling techniques. Using more than 47 000 recordings of 24 instruments from various performers, playing styles, and dynamics, a number of tuning parameters are experimented including the analysis frame size, the dictionary size, and the type of frequency scaling as well as the different sampling and pooling methods. The results show that the combination of proportional sampling and standard deviation pooling achieve the best overall performance of 95.62% while the optimal parameter set varies among the instrument classes.

  20. Parametrization consequences of constraining soil organic matter models by total carbon and radiocarbon using long-term field data

    Science.gov (United States)

    Menichetti, Lorenzo; Kätterer, Thomas; Leifeld, Jens

    2016-05-01

    Soil organic carbon (SOC) dynamics result from different interacting processes and controls on spatial scales from sub-aggregate to pedon to the whole ecosystem. These complex dynamics are translated into models as abundant degrees of freedom. This high number of not directly measurable variables and, on the other hand, very limited data at disposal result in equifinality and parameter uncertainty. Carbon radioisotope measurements are a proxy for SOC age both at annual to decadal (bomb peak based) and centennial to millennial timescales (radio decay based), and thus can be used in addition to total organic C for constraining SOC models. By considering this additional information, uncertainties in model structure and parameters may be reduced. To test this hypothesis we studied SOC dynamics and their defining kinetic parameters in the Zürich Organic Fertilization Experiment (ZOFE) experiment, a > 60-year-old controlled cropland experiment in Switzerland, by utilizing SOC and SO14C time series. To represent different processes we applied five model structures, all stemming from a simple mother model (Introductory Carbon Balance Model - ICBM): (I) two decomposing pools, (II) an inert pool added, (III) three decomposing pools, (IV) two decomposing pools with a substrate control feedback on decomposition, (V) as IV but with also an inert pool. These structures were extended to explicitly represent total SOC and 14C pools. The use of different model structures allowed us to explore model structural uncertainty and the impact of 14C on kinetic parameters. We considered parameter uncertainty by calibrating in a formal Bayesian framework. By varying the relative importance of total SOC and SO14C data in the calibration, we could quantify the effect of the information from these two data streams on estimated model parameters. The weighing of the two data streams was crucial for determining model outcomes, and we suggest including it in future modeling efforts whenever SO14C