WorldWideScience

Sample records for total peak capacity

  1. Peak capacity, peak-capacity production rate, and boiling point resolution for temperature-programmed GC with very high programming rates

    Science.gov (United States)

    Grall; Leonard; Sacks

    2000-02-01

    Recent advances in column heating technology have made possible very fast linear temperature programming for high-speed gas chromatography. A fused-silica capillary column is contained in a tubular metal jacket, which is resistively heated by a precision power supply. With very rapid column heating, the rate of peak-capacity production is significantly enhanced, but the total peak capacity and the boiling-point resolution (minimum boiling-point difference required for the separation of two nonpolar compounds on a nonpolar column) are reduced relative to more conventional heating rates used with convection-oven instruments. As temperature-programming rates increase, elution temperatures also increase with the result that retention may become insignificant prior to elution. This results in inefficient utilization of the down-stream end of the column and causes a loss in the rate of peak-capacity production. The rate of peak-capacity production is increased by the use of shorter columns and higher carrier gas velocities. With high programming rates (100-600 degrees C/min), column lengths of 6-12 m and average linear carrier gas velocities in the 100-150 cm/s range are satisfactory. In this study, the rate of peak-capacity production, the total peak capacity, and the boiling point resolution are determined for C10-C28 n-alkanes using 6-18 m long columns, 50-200 cm/s average carrier gas velocities, and 60-600 degrees C/min programming rates. It was found that with a 6-meter-long, 0.25-mm i.d. column programmed at a rate of 600 degrees C/min, a maximum peak-capacity production rate of 6.1 peaks/s was obtained. A total peak capacity of about 75 peaks was produced in a 37-s long separation spanning a boiling-point range from n-C10 (174 degrees C) to n-C28 (432 degrees C).

  2. Peak capacity and peak capacity per unit time in capillary and microchip zone electrophoresis.

    Science.gov (United States)

    Foley, Joe P; Blackney, Donna M; Ennis, Erin J

    2017-11-10

    The origins of the peak capacity concept are described and the important contributions to the development of that concept in chromatography and electrophoresis are reviewed. Whereas numerous quantitative expressions have been reported for one- and two-dimensional separations, most are focused on chromatographic separations and few, if any, quantitative unbiased expressions have been developed for capillary or microchip zone electrophoresis. Making the common assumption that longitudinal diffusion is the predominant source of zone broadening in capillary electrophoresis, analytical expressions for the peak capacity are derived, first in terms of migration time, diffusion coefficient, migration distance, and desired resolution, and then in terms of the remaining underlying fundamental parameters (electric field, electroosmotic and electrophoretic mobilities) that determine the migration time. The latter expressions clearly illustrate the direct square root dependence of peak capacity on electric field and migration distance and the inverse square root dependence on solute diffusion coefficient. Conditions that result in a high peak capacity will result in a low peak capacity per unit time and vice-versa. For a given symmetrical range of relative electrophoretic mobilities for co- and counter-electroosmotic species (cations and anions), the peak capacity increases with the square root of the electric field even as the temporal window narrows considerably, resulting in a significant reduction in analysis time. Over a broad relative electrophoretic mobility interval [-0.9, 0.9], an approximately two-fold greater amount of peak capacity can be generated for counter-electroosmotic species although it takes about five-fold longer to do so, consistent with the well-known bias in migration time and resolving power for co- and counter-electroosmotic species. The optimum lower bound of the relative electrophoretic mobility interval [μ r,Z , μ r,A ] that provides the maximum

  3. Government procurement of peak capacity in the New Zealand electricity market

    International Nuclear Information System (INIS)

    Poletti, Steve

    2009-01-01

    This paper analyzes the impact of government procurement of reserve electricity generation capacity on the long-run equilibrium in the electricity market. The approach here is to model the electricity market in a context where the supply companies have market power. The model is then used to analyze the impact of government direct supply of peak capacity on the market. We find that the firms build less peak-generation capacity when the government procures peak generating capacity. The long-run equilibrium with N firms and government capacity of K G results in an increase of total peak generation capacity of K G /(N+1) compared to the long-run equilibrium with no government capacity. Supply disruptions of baseline capacity during the peak time period are also considered. It is found that peak prices do not go up any further with (anticipated) supply disruptions. Instead the entire cost of the extra peakers is borne by customers on traditional meters and off-peak customers who face real-time pricing. (author)

  4. Marrying Step Feed with Secondary Clarifier Improvements to Significantly Increase Peak Wet Weather Treatment Capacity: An Integrated Methodology.

    Science.gov (United States)

    Daigger, Glen T; Siczka, John S; Smith, Thomas F; Frank, David A; McCorquodale, J A

    2017-08-01

      The need to increase the peak wet weather secondary treatment capacity of the City of Akron, Ohio, Water Reclamation Facility (WRF) provided the opportunity to test an integrated methodology for maximizing the peak wet weather secondary treatment capacity of activated sludge systems. An initial investigation, consisting of process modeling of the secondary treatment system and computational fluid dynamics (CFD) analysis of the existing relatively shallow secondary clarifiers (3.3 and 3.7 m sidewater depth in 30.5 m diameter units), indicated that a significant increase in capacity from 416 000 to 684 000 m3/d or more was possible by adding step feed capabilities to the existing bioreactors and upgrading the existing secondary clarifiers. One of the six treatment units at the WRF was modified, and an extensive 2-year testing program was conducted to determine the total peak wet weather secondary treatment capacity achievable. The results demonstrated that a peak wet weather secondary treatment capacity approaching 974 000 m3/d is possible as long as secondary clarifier solids and hydraulic loadings could be separately controlled using the step feed capability provided. Excellent sludge settling characteristics are routinely experienced at the City of Akron WRF, raising concerns that the identified peak wet weather secondary treatment capacity could not be maintained should sludge settling characteristics deteriorate for some reason. Computational fluid dynamics analysis indicated that the impact of the deterioration of sludge settling characteristics could be mitigated and the identified peak wet weather secondary treatment capacity maintained by further use of the step feed capability provided to further reduce secondary clarifier solids loading rates at the identified high surface overflow rates. The results also demonstrated that effluent limits not only for total suspended solids (TSS) and five-day carbonaceous biochemical oxygen demand (cBOD5) could be

  5. Total iron binding capacity

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003489.htm Total iron binding capacity To use the sharing features on this page, please enable JavaScript. Total iron binding capacity (TIBC) is a blood test to ...

  6. Free-space optical communications with peak and average constraints: High SNR capacity approximation

    KAUST Repository

    Chaaban, Anas

    2015-09-07

    The capacity of the intensity-modulation direct-detection (IM-DD) free-space optical channel with both average and peak intensity constraints is studied. A new capacity lower bound is derived by using a truncated-Gaussian input distribution. Numerical evaluation shows that this capacity lower bound is nearly tight at high signal-to-noise ratio (SNR), while it is shown analytically that the gap to capacity upper bounds is a small constant at high SNR. In particular, the gap to the high-SNR asymptotic capacity of the channel under either a peak or an average constraint is small. This leads to a simple approximation of the high SNR capacity. Additionally, a new capacity upper bound is derived using sphere-packing arguments. This bound is tight at high SNR for a channel with a dominant peak constraint.

  7. Peak regulation right

    International Nuclear Information System (INIS)

    Gao, Z. |; Ren, Z.; Li, Z.; Zhu, R.

    2005-01-01

    A peak regulation right concept and corresponding transaction mechanism for an electricity market was presented. The market was based on a power pool and independent system operator (ISO) model. Peak regulation right (PRR) was defined as a downward regulation capacity purchase option which allowed PRR owners to buy certain quantities of peak regulation capacity (PRC) at a specific price during a specified period from suppliers. The PRR owner also had the right to decide whether or not they would buy PRC from suppliers. It was the power pool's responsibility to provide competitive and fair peak regulation trading markets to participants. The introduction of PRR allowed for unit capacity regulation. The PRR and PRC were rated by the supplier, and transactions proceeded through a bidding process. PRR suppliers obtained profits by selling PRR and PRC, and obtained downward regulation fees regardless of whether purchases are made. It was concluded that the peak regulation mechanism reduced the total cost of the generating system and increased the social surplus. 6 refs., 1 tab., 3 figs

  8. Aerobic capacity and peak power output of elite quadriplegic games players

    Science.gov (United States)

    Goosey‐Tolfrey, V; Castle, P; Webborn, N

    2006-01-01

    Background Participation in wheelchair sports such as tennis and rugby enables people with quadriplegia to compete both individually and as a team at the highest level. Both sports are dominated by frequent, intermittent, short term power demands superimposed on a background of aerobic activity. Objective To gain physiological profiles of highly trained British quadriplegic athletes, and to examine the relation between aerobic and sprint capacity. Methods Eight male quadriplegic athletes performed an arm crank exercise using an ergometer fitted with a Schoberer Rad Messtechnik (SRM) powermeter. The sprint test consisted of three maximum‐effort sprints of five seconds duration against a resistance of 2%, 3%, and 4% of body mass. The highest power output obtained was recorded (PPO). Peak oxygen consumption (V̇o2peak), peak heart rate (HRpeak), and maximal power output (POaer) were determined. Results Mean POaer was 67.7 (16.2) W, mean V̇o2peak was 0.96 (0.17) litres/min, and HRpeak was 134 (19) beats/min for the group. There was high variability among subjects. Peak power over the five second sprint for the group was 220 (62) W. There was a significant correlation between V̇o2peak (litres/min) and POaer (W) (r  =  0.74, p<0.05). Conclusions These British quadriplegic athletes have relatively high aerobic fitness when compared with the available literature. Moreover, the anaerobic capacity of these athletes appeared to be relatively high compared with paraplegic participants. PMID:16611721

  9. The Potential for Energy Storage to Provide Peaking Capacity in California under Increased Penetration of Solar Photovoltaics: Report Summary

    Energy Technology Data Exchange (ETDEWEB)

    Denholm, Paul L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-03-12

    Opportunities to provide peaking capacity with low-cost energy storage are emerging. But adding storage changes the ability of subsequent storage additions to meet peak demand. Increasing photovoltaic (PV) deployment also affects storage's ability to provide peak capacity. This study examines storage's potential to replace conventional peak capacity in California.

  10. Several peaks of total current in Trichel pulse

    International Nuclear Information System (INIS)

    Bolotov, O.; Golota, V.; Kadolin, B.; Mankovskyi, S.; Ostroushko, V.; Pashchenko, I.; Taran, G.; Zavada, L.

    2015-01-01

    The numerical simulations of negative corona at constant voltage in Trichel pulse mode are carried out in assumptions of presence and absence of photoemission from cathode. In absence of photoemission two peaks of total current or the step before the main peak were obtained for very small values of ion-electron emission coefficient. In presence of photoemission there were observed several maximums, connected with instability development of the process based on radiation of photons, photoemission, and avalanche multiplication

  11. Potential of energy-oriented network optimisation: Switching off over-capacity in off-peak hours

    NARCIS (Netherlands)

    Litjens, R.; Jorguseski, L.

    2010-01-01

    Mobile communication networks are usually planned to provide some minimum service quality level during peak traffic hours. Consequently, in off-peak hours, when traffic loads are lower, the network is characterised by over-capacity, in the sense that same service quality targets can typically be

  12. Bulk power system performance issues affecting utility peaking capacity additions

    Energy Technology Data Exchange (ETDEWEB)

    Garrity, T.F. [GE Power Sytems, Schenectady, NY (United States)

    1994-12-31

    This paper presents a discussion of transmission system constraints and problems that affect the siting and rating of peaking capacity additions. Techniques for addressing and modifying these concerns are presented. Particular attention is paid to techniques that have been successfully used by utilities to improve power transfer and system loadability, while avoiding the construction of additional transmission lines. Proven techniques for dealing with thermal, short-circuit level and stability issues are presented.

  13. Total antioxidant capacity in children with acute appendicitis.

    Science.gov (United States)

    Kaya, M; Boleken, M E; Kanmaz, T; Erel, O; Yucesan, S

    2006-02-01

    This study aimed to investigate antioxidant capacity by using a novel automated method in children with acute appendicitis. Blood samples were obtained from consecutive patients with acute appendicitis (appendicitis group, n = 12) and acute abdominal pain due to non surgical disease (non-appendicitis group, n = 11), and from patients with inguinal hernia (healthy group, n = 12) as the control group. At admission, total antioxidant capacity (TAC) levels of plasma were evaluated in all patients by a method recently developed by Erel. Four other major individual plasma antioxidant components, the levels of total protein, albumin, uric acid and bilirubin, were also evaluated. Total antioxidant capacity in patients with acute appendicitis was statistically compared with the two other groups. While the TAC level in the appendicitis group was significantly greater than in the non-appendicitis group, no significant difference was found in healthy groups (p 0.05, 1.94 +/- 0.38, 1.40 +/- 0.36, and 1.99 +/- 0.35 respectively). Individual components of total antioxidant capacity, i.e. total protein, albumin, uric acid and bilirubin concentrations, were also higher in the patients with acute appendicitis than those of the other two control groups. Our data show that children with acute appendicitis do not have deficient blood plasma antioxidant capacity. These results provide evidence that acute appendicitis results in more induction of antioxidative response than non-surgical diseases.

  14. Evaluating total carrying capacity of tourism using impact indicators

    Directory of Open Access Journals (Sweden)

    R. Sharma

    2016-03-01

    Full Text Available The carrying capacity is well identified tool to manage problems due to uncontrolled tourism for any destination. This report highlights the carrying capacity estimation of Kerwa tourism area, Bhopal, India. The methodology used in this report is a new two-tier mechanism of impact analysis using index numbers derived from a survey of 123 stakeholders. From this the individual component impact analysis and the total carrying capacity of the area is computed in order to state the insight of the total carrying capacity left for the tourism activities in Kerwa tourism area. It is calculated from, the results so obtained, that the Kerwa catchment area falls in “very low impact category” and hence in a healthy state of the artwork in terms of total carrying capacity. The study conveys the current need in the destination management and tourism development as a road map for the destination managers for implementing sustainable tourism.

  15. Improved Peak Capacity for Capillary Electrophoretic Separations of Enzyme Inhibitors with Activity-Based Detection Using Magnetic Bead Microreactors

    Science.gov (United States)

    Yan, Xiaoyan; Gilman, S. Douglass

    2010-01-01

    A technique for separating and detecting enzyme inhibitors was developed using capillary electrophoresis with an enzyme microreactor. The on-column enzyme microreactor was constructed using NdFeB magnet(s) to immobilize alkaline phosphatase-coated superparamagnetic beads (2.8 μm diameter) inside a capillary before the detection window. Enzyme inhibition assays were performed by injecting a plug of inhibitor into a capillary filled with the substrate, AttoPhos. Product generated in the enzyme microreactor was detected by laser-induced fluorescence. Inhibitor zones electrophoresed through the capillary, passed through the enzyme microreactor, and were observed as negative peaks due to decreased product formation. The goal of this study was to improve peak capacities for inhibitor separations relative to previous work, which combined continuous engagement electrophoretically mediated microanalysis (EMMA) and transient engagement EMMA to study enzyme inhibition. The effects of electric field strength, bead injection time and inhibitor concentrations on peak capacity and peak width were investigated. Peak capacities were increased to ≥20 under optimal conditions of electric field strength and bead injection time for inhibition assays with arsenate and theophylline. Five reversible inhibitors of alkaline phosphatase (theophylline, vanadate, arsenate, L-tryptophan and tungstate) were separated and detected to demonstrate the ability of this technique to analyze complex inhibitor mixtures. PMID:20024913

  16. An empirical method for peak-to-total ratio computation of a gamma-ray detector

    International Nuclear Information System (INIS)

    Cesana, A.; Terrani, M.

    1989-01-01

    A simple expression for peak-to-total ratio evaluation of gamma-ray detectors in the energy range 0.3-10 MeV is proposed. The quantities one needs to know for the computation are: Detector dimensions and chemical composition, photon corss sections and an empirical energy dependent function which is valid for all the detector materials considered. This procedure seems able to produce peak-to-total values with an accuracy comparable with the most sophisticated Monte Carlo calculations. It has been tested using experimental peak-to-total values of Ge, NaI, CsI and BGO detectors but it is reasonable to suppose that it is valid for any detector material. (orig.)

  17. The Potential for Energy Storage to Provide Peaking Capacity in California Under Increased Penetration of Solar Photovoltaics

    Energy Technology Data Exchange (ETDEWEB)

    Denholm, Paul L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-03-14

    In this report, we examine the potential for replacing conventional peaking capacity in California with energy storage, including analysis of the changing technical potential with increased storage deployment and the effect of PV deployment. We examine nine years of historic load data, a range of storage durations (2-8 hours), and a range of PV penetration levels (0%-30%). We demonstrate how PV increases the ability of storage to reduce peak net demand. In the scenarios analyzed, the expected penetration of PV in California in 2020 could more than double the potential for 4-hour energy storage to provide capacity services.

  18. Relative Economic Merits of Storage and Combustion Turbines for Meeting Peak Capacity Requirements under Increased Penetration of Solar Photovoltaics

    Energy Technology Data Exchange (ETDEWEB)

    Denholm, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Diakov, Victor [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Batteries with several hours of capacity provide an alternative to combustion turbines for meeting peak capacity requirements. Even when compared to state-of-the-art highly flexible combustion turbines, batteries can provide a greater operational value, which is reflected in a lower system-wide production cost. By shifting load and providing operating reserves, batteries can reduce the cost of operating the power system to a traditional electric utility. This added value means that, depending on battery life, batteries can have a higher cost than a combustion turbine of equal capacity and still produce a system with equal or lower overall life-cycle cost. For a utility considering investing in new capacity, the cost premium for batteries is highly sensitive to a variety of factors, including lifetime, natural gas costs, PV penetration, and grid generation mix. In addition, as PV penetration increases, the net electricity demand profile changes, which may reduce the amount of battery energy capacity needed to reliably meet peak demand.

  19. State-of-health monitoring of lithium-ion battery modules and packs via incremental capacity peak tracking

    International Nuclear Information System (INIS)

    Weng, Caihao; Feng, Xuning; Sun, Jing; Peng, Huei

    2016-01-01

    Highlights: • A new framework based on ICA is used to monitor SOH on-board for battery packs. • The applicability of the framework is validated through simulation and experiment. • The method can monitor SOH for pack consisting of cells with various aging paths. • On-board incremental capacity analysis is realized by support vector regression. - Abstract: Incremental capacity analysis (ICA) is a widely used technique for lithium-ion battery state-of-health (SOH) evaluation. The effectiveness and robustness of ICA for single cell diagnostics have been reported in many published work. In this study, we extend the ICA based SOH monitoring approach from single cells to battery modules, which consist of battery cells with various aging conditions. In order to achieve on-board implementation, an IC peak tracking approach based on the ICA principles is proposed. Analytical, numerical and experimental results are presented to demonstrate the utility of the IC peak tracking framework on multi-cell battery SOH monitoring and the effects of cell non-uniformity on the proposed method. Results show that the methods developed for single cell capacity estimation can also be used for a module or pack that has parallel-connected cells.

  20. Systematic evaluation of commercially available ultra-high performance liquid chromatography columns for drug metabolite profiling: optimization of chromatographic peak capacity.

    Science.gov (United States)

    Dubbelman, Anne-Charlotte; Cuyckens, Filip; Dillen, Lieve; Gross, Gerhard; Hankemeier, Thomas; Vreeken, Rob J

    2014-12-29

    The present study investigated the practical use of modern ultra-high performance liquid chromatography (UHPLC) separation techniques for drug metabolite profiling, aiming to develop a widely applicable, high-throughput, easy-to-use chromatographic method, with a high chromatographic resolution to accommodate simultaneous qualitative and quantitative analysis of small-molecule drugs and metabolites in biological matrices. To this end, first the UHPLC system volume and variance were evaluated. Then, a mixture of 17 drugs and various metabolites (molecular mass of 151-749Da, logP of -1.04 to 6.7), was injected on six sub-2μm particle columns. Five newest generation core shell technology columns were compared and tested against one column packed with porous particles. Two aqueous (pH 2.7 and 6.8) and two organic mobile phases were evaluated, first with the same flow and temperature and subsequently at each column's individual limit of temperature and pressure. The results demonstrated that pre-column dead volume had negligible influence on the peak capacity and shape. In contrast, a decrease in post-column volume of 57% resulted in a substantial (47%) increase in median peak capacity and significantly improved peak shape. When the various combinations of stationary and mobile phases were used at the same flow rate (0.5mL/min) and temperature (45°C), limited differences were observed between the median peak capacities, with a maximum of 26%. At higher flow though (up to 0.9mL/min), a maximum difference of almost 40% in median peak capacity was found between columns. The finally selected combination of solid-core particle column and mobile phase composition was chosen for its selectivity, peak capacity, wide applicability and peak shape. The developed method was applied to rat hepatocyte samples incubated with the drug buspirone and demonstrated to provide a similar chromatographic resolution, but a 6 times higher signal-to-noise ratio than a more traditional UHPLC

  1. Serum total antioxidant capacity in patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Almira Hadžović-Džuvo

    2011-02-01

    Full Text Available Multiple sclerosis (MS is a chronic inflammatory disease of the central nervous system (CNS. It is characterized by loss of myelin, the fatty tissue that surrounds and protects nerve fibres allowing them to conduct electrical impulses. Recent data indicate that oxidative stress (OS plays a major role in the pathogenesis of multiple sclerosis (MS. The aim of this study was to estimate level of serum total antioxidative capacity in patients with multiple sclerosis. Our cross-sectional study included 33 patients with MS and 24 age and sex matched control subjects. All our patients had a Poser criteria for definite diagnostic categories of multiple sclerosis. Serum total antioxidant capacity (TAC was measured by quantitative colorimetric determination, using Total antioxidant Capacity-QuantiCromAntioxidant Assay Kit (BioAssay systems, USA; DTAC-100. Mean serum TAC in multiple sclerosis group of patients was 119.2 mM Trolox equivalents and was significantly lower (p<0.001 compared to the control group of subjects (167.1 mM Trolox equivalents. Our results showed that oxidative stress plays an important role in pathogenesis of multiple sclerosis. This finding, also, suggests the importance of antioxidants in diet and therapy of MS patients.

  2. Estimation of salivary flow rate, pH, buffer capacity, calcium, total protein content and total antioxidant capacity in relation to dental caries severity, age and gender.

    Science.gov (United States)

    Pandey, Pallavi; Reddy, N Venugopal; Rao, V Arun Prasad; Saxena, Aditya; Chaudhary, C P

    2015-03-01

    The aim of the study was to evaluate salivary flow rate, pH, buffering capacity, calcium, total protein content and total antioxidant capacity in relation to dental caries, age and gender. The study population consisted of 120 healthy children aged 7-15 years that was further divided into two groups: 7-10 years and 11-15 years. In this 60 children with DMFS/dfs = 0 and 60 children with DMFS/dfs ≥5 were included. The subjects were divided into two groups; Group A: Children with DMFS/dfs = 0 (caries-free) Group B: Children with DMFS/dfs ≥5 (caries active). Unstimulated saliva samples were collected from all groups. Flow rates were determined, and samples analyzed for pH, buffer capacity, calcium, total protein and total antioxidant status. Salivary antioxidant activity is measured with spectrophotometer by an adaptation of 2,2'-azino-di-(3-ethylbenzthiazoline-6-sulphonate) assays. The mean difference of the two groups; caries-free and caries active were proved to be statistically significant (P salivary calcium, total protein and total antioxidant level for both the sexes in the age group 7-10 years and for the age 11-15 years the mean difference of the two groups were proved to be statistically significant (P salivary calcium level for both the sexes. Salivary total protein and total antioxidant level were proved to be statistically significant for male children only. In general, total protein and total antioxidants in saliva were increased with caries activity. Calcium content of saliva was found to be more in caries-free group and increased with age.

  3. Peak capacity analysis of coal power in China based on full-life cycle cost model optimization

    Science.gov (United States)

    Yan, Xiaoqing; Zhang, Jinfang; Huang, Xinting

    2018-02-01

    13th five-year and the next period are critical for the energy and power reform of China. In order to ease the excessive power supply, policies have been introduced by National Energy Board especially toward coal power capacity control. Therefore the rational construction scale and scientific development timing for coal power are of great importance and paid more and more attentions. In this study, the comprehensive influence of coal power reduction policies is analyzed from diverse point of views. Full-life cycle cost model of coal power is established to fully reflect the external and internal cost. Then this model is introduced in an improved power planning optimization theory. The power planning and diverse scenarios production simulation shows that, in order to meet the power, electricity and peak balance of power system, China’s coal power peak capacity is within 1.15 ∼ 1.2 billion kilowatts before or after 2025. The research result is expected to be helpful to the power industry in 14th and 15th five-year periods, promoting the efficiency and safety of power system.

  4. Assessing peak aerobic capacity in Dutch law enforcement officers

    Directory of Open Access Journals (Sweden)

    Harriet Wittink

    2015-06-01

    Full Text Available Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report normative absolute and relative VO2peak values of a sample of law enforcement officers in the Netherlands. Material and Methods: The peak rate of oxygen consumption (ml×kg–1×min–1 was measured using a maximal incremental bicycle test in 1530 subjects, including 1068 male and 461 female police officers. Validity of the prediction equations for groups was assessed by comparing predicted VO2peak with measured VO2peak using paired t-tests. For individual differences limits of agreement (LoA were calculated. Equations were considered valid for individuals when the difference between measured and predicted VO2peak did not exceed ±1 metabolic equivalent (MET in 95% of individuals. Results: None of the equations met the validity criterion of 95% of individuals having ±1 MET difference or less than the measured value. Limits of agreement (LoAs were large in all predictions. At the individual level, none of the equations were valid predictors of VO2peak (ml×kg–1×min–1. Normative values for Dutch law enforcement officers were presented. Conclusions: Substantial differences between measured and predicted VO2peak (ml×kg–1×min–1 were found. Most tested equations were invalid predictors of VO2peak at group level and all were invalid at individual levels.

  5. Assessing peak aerobic capacity in Dutch law enforcement officers

    NARCIS (Netherlands)

    Wittink, Harriet; Takken, Tim; de Groot, Janke; Reneman, Michiel; Peters, Roelof; Vanhees, Luc

    2015-01-01

    Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak) prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report

  6. Assessing peak aerobic capacity in Dutch law enforcement officers.

    NARCIS (Netherlands)

    Wittink, H.; Takken, T.; Groot, J.F. de; Reneman, M.; Peters, R.; Vanhees, L.

    2015-01-01

    Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak) prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report

  7. Climate change and peak demand for electricity: Evaluating policies for reducing peak demand under different climate change scenarios

    Science.gov (United States)

    Anthony, Abigail Walker

    This research focuses on the relative advantages and disadvantages of using price-based and quantity-based controls for electricity markets. It also presents a detailed analysis of one specific approach to quantity based controls: the SmartAC program implemented in Stockton, California. Finally, the research forecasts electricity demand under various climate scenarios, and estimates potential cost savings that could result from a direct quantity control program over the next 50 years in each scenario. The traditional approach to dealing with the problem of peak demand for electricity is to invest in a large stock of excess capital that is rarely used, thereby greatly increasing production costs. Because this approach has proved so expensive, there has been a focus on identifying alternative approaches for dealing with peak demand problems. This research focuses on two approaches: price based approaches, such as real time pricing, and quantity based approaches, whereby the utility directly controls at least some elements of electricity used by consumers. This research suggests that well-designed policies for reducing peak demand might include both price and quantity controls. In theory, sufficiently high peak prices occurring during periods of peak demand and/or low supply can cause the quantity of electricity demanded to decline until demand is in balance with system capacity, potentially reducing the total amount of generation capacity needed to meet demand and helping meet electricity demand at the lowest cost. However, consumers need to be well informed about real-time prices for the pricing strategy to work as well as theory suggests. While this might be an appropriate assumption for large industrial and commercial users who have potentially large economic incentives, there is not yet enough research on whether households will fully understand and respond to real-time prices. Thus, while real-time pricing can be an effective tool for addressing the peak load

  8. Environmental impacts of public transport. Why peak-period travellers cause a greater environmental burden than off-peak travellers

    International Nuclear Information System (INIS)

    Rietveld, P.

    2002-01-01

    Given the difference between peak and off-peak occupancy rates in public transport, emissions per traveller kilometre are lower in the peak than in the off-peak period, whereas the opposite pattern is observed for cars. It is argued that it is much more fruitful to analyse environmental effects in marginal terms. This calls for a careful analysis of capacity management policies of public transport suppliers that are facing increased demand during both peak and off-peak periods. A detailed analysis of capacity management by the Netherlands Railways (NS) revealed that off-peak capacity supply is mainly dictated by the demand levels during the peak period. The analysis included the effects of increased frequency and increased vehicle size on environmental impacts, while environmental economies of vehicle size were also taken into account. The main conclusion is that the marginal environmental burden during the peak hours is much higher than is usually thought, whereas it is almost zero during the off-peak period. This implies a pattern that is the precise opposite of the average environmental burden. Thus, an analysis of environmental effects of public transport based on average performance would yield misleading conclusions [nl

  9. Effect of gamma radiation on total antioxidant capacity, total lipid concentration and shelf life of finger millet flour

    International Nuclear Information System (INIS)

    Lathika; Manupriya, B.R.; Shenoy, K.B.; Patil, S.L.; Somashekarappa, H.M.

    2016-01-01

    The present study is an attempt to study the impact of gamma radiation on the shelf life, total antioxidant capacity and total lipid concentration of finger millet (Eleusine coracana L.) flour. Finger millet flour was procured from market. Flour samples of 50 g were taken in triplicates in a polyethylene pouch, air sealed and subjected to gamma irradiation doses ranging from 0.25 to 10 kGy and stored in polyethylene bags and plastic containers for a period of 1 year. Within 24 hours of irradiation, the samples were tested for moisture (2 ± 0.2%), total antioxidant capacity (0.12 ± 0.010 mg) and lipid concentration (15 ± 0.4 mg)

  10. South African dietary total antioxidant capacity based on secondary ...

    African Journals Online (AJOL)

    Objective: In this exploratory study, the average adult South African dietary total antioxidant capacity (TAC) was estimated using secondary data and was evaluated against that determined for dietary intake recommendations. Design: The average adult South African dietary TAC was estimated using a report published by ...

  11. Antioxidant Capacities and Total Phenolic Contents of 56 Wild Fruits from South China

    Directory of Open Access Journals (Sweden)

    Hua-Bin Li

    2010-11-01

    Full Text Available In order to identify wild fruits possessing high nutraceutical potential, the antioxidant activities of 56 wild fruits from South China were systematically evaluated. The fat-soluble components were extracted with tetrahydrofuran, and the water-soluble ones were extracted with a 50:3.7:46.3 (v/v methanol-acetic acid-water mixture. The antioxidant capacities of the extracts were evaluated using the ferric reducing antioxidant power (FRAP and Trolox equivalent antioxidant capacity (TEAC assays, and their total phenolic contents were measured by the Folin-Ciocalteu method. Most of these wild fruits were analyzed for the first time for their antioxidant activities. Generally, these fruits had high antioxidant capacities and total phenolic contents. A significant correlation between the FRAP value and the TEAC value suggested that antioxidant components in these wild fruits were capable of reducing oxidants and scavenging free radicals. A high correlation between antioxidant capacity and total phenolic content indicated that phenolic compounds could be the main contributors to the measured antioxidant activity. The results showed that fruits of Eucalyptus robusta, Eurya nitida, Melastoma sanguineum, Melaleuca leucadendron, Lagerstroemia indica, Caryota mitis, Lagerstroemia speciosa and Gordonia axillaris possessed the highest antioxidant capacities and total phenolic contents among those tested, and could be potential rich sources of natural antioxidants and functional foods. The results obtained are very helpful for the full utilization of these wild fruits.

  12. Relationship between low-temperature boson heat capacity peak and high-temperature shear modulus relaxation in a metallic glass

    International Nuclear Information System (INIS)

    Vasiliev, A. N.; Voloshok, T. N.; Granato, A. V.; Joncich, D. M.; Mitrofanov, Yu. P.; Khonik, V. A.

    2009-01-01

    Low-temperature (2 K≤T≤350 K) heat capacity and room-temperature shear modulus measurements (ν=1.4 MHz) have been performed on bulk Pd 41.25 Cu 41.25 P 17.5 in the initial glassy, relaxed glassy, and crystallized states. It has been found that the height of the low-temperature Boson heat capacity peak strongly correlates with the changes in the shear modulus upon high-temperature annealing. It is this behavior that was earlier predicted by the interstitialcy theory, according to which dumbbell interstitialcy defects are responsible for a number of thermodynamic and kinetic properties of crystalline, (supercooled) liquid, and solid glassy states.

  13. Antioxidant capacity and total polyphenol content in different apple varieties cultivated in Chile

    OpenAIRE

    Quitral, Vilma; Sepulveda, Marcela; Schwartz, Marco; Kern, Werther

    2014-01-01

    Three apple varieties cultivated in Chile were studied in total polyphenol content by Folin Ciocalteu method and antioxidant capacity by FRAP method: Granny Smith, Royal Gala and Fuji (whole and peeled apples). The total polyphenol content in whole and peeled apples do not show significant differences. The antioxidant capacity of the Granny Smith variety is significantly higher than Royal Gala and Fuji. Apple dehydration at 60 oC for 4 hours to obtain flakes keeps polyphenol content high. The...

  14. Plasma total antioxidant capacity (TAC) in obese Malaysian subjects.

    Science.gov (United States)

    Lim, S H; Fan, S H; Say, Y H

    2012-12-01

    There is a pressing need to better understand the complex biochemical pathways that lead to the pathogenesis of obesity. Increased oxidative stress and decreased antioxidant capacity have been identified to be associated with obesity. Therefore, the objectives of this study were to determine the plasma total antioxidant capacity (TAC) levels of Malaysian subjects and to evaluate its potential association with obesity and related anthropometric measurements. Plasma TAC of 362 multi-ethnic Malaysian subjects from the Kampar Health Clinic (138 males, 224 females; 124 ethnic Malays, 152 Chinese, 86 Indians; 192 non-obese, 170 obese) was measured using Trolox equivalent antioxidant capacity (TEAC) 96-well plate assay. Plasma TAC was significantly lower in obese subjects (M +/- SE = 292 +/- 10.4 micromol/L) compared to non-obese subjects (397 +/- 8.58 micromol/L), whereas it was significantly higher in males and those in the 21-30 age group. Those with salty food preference and practising a strict vegetarian diet also had significantly higher plasma TAC. However, no association was found for other dietary habits (coffee intake) and lifestyle factors (physical activity, smoking). Plasma TAC was also significantly negatively correlated with diastolic blood pressure, waist and hip circumferences, weight, body mass index, total body fat, % subcutaneous fat, visceral fat level, resting metabolism and % skeletal muscle. Plasma TAC was found to be associated with obesity, strict vegetarian practice, salty food preference and all obesity anthropometric indicators, except systolic blood pressure and pulse rate. Obese people have decreased plasma TAC indicating a compromised systemic antioxidant defence and increased oxidative stress.

  15. Total antioxidant capacity, total phenolic content and mineral elements in the fruit peel of Myrciaria cauliflora

    Directory of Open Access Journals (Sweden)

    Clináscia Rodrigues Rocha Araújo

    2013-12-01

    Full Text Available The in vitro antioxidant capacity, total phenolic content and mineral elements of the fruit peel of Myrciaria cauliflora were investigated. The antioxidant capacity was analyzed by the diphenylpicrylhydrazyl (DPPH, 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid (ABTS, ferric reducing antioxidant power (FRAP and β-carotene methods. The assays based on the DPPH (EC50 = 3.18 g sample/g DPPH, ABTS•+ (1017 μmol Trolox/g sample, FRAP (1676 µM Fe2SO4/g sample and β-carotene/linoleic acid (70% of oxidation inhibition methods indicated a high antioxidant capacity of the fruit peel extract of the plant. The Folin-Denis method was more efficient in determining the total phenolic compound contents in the different solvents than the Folin-Ciocalteu one. Extractions made with 4:1 methanol-water, 4:1 ethanol-water, 3:2 ethanol-water and 3:2 acetone-water solutions using the Folin-Denis method exhibited high contents of phenolic compounds (18.95, 14.06, 12.93 and 11.99 mg GAE/g, respectively. Potassium was the major element found in the fruit peel, followed by phosphorus, calcium, magnesium and iron, in that order. As a result, the fruit peel of M. cauliflora can be considered as an important source of natural antioxidants and essential elements of easy access for the population and for application in the food industry.

  16. Locational Prices in Capacity Subscription Market Considering Transmission Limitations

    Directory of Open Access Journals (Sweden)

    S. Babaeinejad Sarookolaee

    2013-06-01

    Full Text Available This study focuses on one of the most effective type of capacity markets named Capacity Subscription (CS market which is predicted to be widely used in the upcoming smart grids. Despite variant researches done about the mechanism and structure of capacity markets, their performances have been rarely tested in the presence of network constraints. Considering this deficiency, we tried to propose a new method to determine capacity prices in the network considering the transmission line flow limitations named Local capacity Prices (LP. This method is quite new and has not been tried before in any other similar researches. The philosophy of the proposed method is to determine capacity prices considering each consumer share of total peak demand. The first advantage of LP is that the consumers who benefit from the transmission facilities and are the responsible for transmission congestions, pay higher capacity prices than those whom their needed electricity is prepared locally. The second advantage of LP is that consumers connected to the same bus do not have to pay same capacity price due to their different shares of total peak demand. For more clarification, two other different methods named Branches Flow limit as a Global Limit (BFGL and Locational Capacity Prices (LCP are proposed and compared to the LP method in order to show LP method efficiency. The numerical results obtained from case studies show that the LP method follows more justice market procedure which results in more efficient capacity prices in comparison to BFGL and LCP methods.

  17. Total Phenolic Content and Antioxidant Capacity of Radish as Influenced by the Variety and Vegetative Stage

    Directory of Open Access Journals (Sweden)

    Maria Doinița Borș

    2015-05-01

    Full Text Available This study investigates the influence of the variety and vegetative stage on the total phenolic content and antioxidant capacity of radish. Samples of seeds, sprouts (day-3, day-5 and day-7 and roots of three varieties (red, white and black of radish (Raphanussativus were collected and tested for the above-mentioned parameters. Determination of total phenolic content was performed by Folin-Ciocalteau assay and antioxidant activity by DPPH assay. The total phenolic content ranged between 4.75 and 19.44 mg GAE/g DW and the antioxidant capacity between 12 and 75%. The highest total phenolic content and antioxidant capacity was found in radish sprouts and the lowest in radish roots, and among samples in the black radish variety. 

  18. Evaluation of total polyphenol content and antioxidant capacity of different verity lupin seeds

    Directory of Open Access Journals (Sweden)

    Ismael Sulaiman Dalaram

    2017-01-01

    Full Text Available Legumes, including lupins, beans, lentil and chickpea, are one of the most important crops in the world because of their nutritional quality. Lupin seeds have been used as human food and animal feed since ancient times. It was known that antioxidant photochemical in foods have many health benefits including prevention of various diseases associated with oxidative stress such as cancer, cardiovascular disease, neuro-degeneration and diabetes. Lupin grains are rich sources of complex carbohydrates, protein, vitamins and minerals. Antioxidants can be found naturally in foods. Total polyphenols content and antioxidant activity were measured in four varieties of lupin, namely in white lupin, blue lupin, yellow lupin and Mutabilis lupin species. A majority of antioxidants naturally present in foods occur in phenolic structures and especially in flavonoid structures. The content of the total polyphenols was determined by using the Folin-Ciocalteu reagent (FCR. Antioxidant activity was measured by using a compound DPPH˙ (2.2-diphenyl-1-picrylhydrazyl. In the present experiment according to the average contents of total polyphenols (TPC in dry matter of lupin seeds there was the following line: L. Angustifolius (blue lupin (696.212 mg GAE.100g-1 > L. Albus (white lupin (614.13 mg GAE.100g-1 > L. Luteus (yellow lupin (467.78 mg GAE.100g-1 > L. Mutabilis (pearl lupin (367.36 mg GAE.100g-1. Based on the measured values of total antioxidant capacity (TAC of lupin samples can be classified as follows: L. Albus (white lupin (43.44% >L. Angustifolius (blue lupin (38.27% >L. Luteus (yellow lupin (22.29% >L. Mutabilis (Pearl lupin (20.80%. The relationship of antioxidant capacity with total polyphenolic was discussed. According to used statistical analyzes. Correlation between the phenolic contents and antioxidant capacity was significantly positive (r = 0.88. Our results confirmed that legumes can be a good source of bioactive compounds in the human nutrition

  19. From a single encapsulated detector to the spectrometer for INTEGRAL satellite: predicting the peak-to-total ratio at high γ-energies

    International Nuclear Information System (INIS)

    Kshetri, R

    2012-01-01

    In two recent papers (R. Kshetri, JINST 2012 7 P04008; ibid., P07006), a probabilistic formalism was introduced to predict the response of encapsulated type composite germanium detectors like the SPI (spectrometer for INTEGRAL satellite). Predictions for the peak-to-total and peak-to-background ratios are given at 1.3 MeV for the addback mode of operation. The application of the formalism to clover germanium detector is discussed in two separate papers (R. Kshetri, JINST 2012 7 P07008; ibid., P08015). Using the basic approach developed in those papers, for the first time we present a procedure for calculating the peak-to-total ratio of the cluster detector for γ-energies up to 8 MeV. Results are shown for both bare and suppressed detectors as well as for the single crystal and addback modes of operation. We have considered the experimental data of (i) peak-to-total ratio at 1.3 MeV, and (ii) single detector efficiency and addback factor for other energies up to 8 MeV. Using this data, an approximate method of calculating the peak-to-total ratio of other composite detectors, is shown. Experimental validation of our approach (for energies up to 8 MeV) has been confirmed considering the data of the SPI spectrometer. We have discussed about comparisons between various modes of operation and suppression cases. The present paper is the fifth in the series of papers on composite germanium detectors and for the first time discusses about the change in fold distribution and peak-to-total ratio for sophisticated detectors consisting of several modules of miniball, cluster and SPI detectors. Our work could provide a guidance in designing new composite detectors and in performing experimental studies with the existing detectors for high energy gamma-rays.

  20. From a single encapsulated detector to the spectrometer for INTEGRAL satellite: predicting the peak-to-total ratio at high γ-energies

    Science.gov (United States)

    Kshetri, R.

    2012-12-01

    In two recent papers (R. Kshetri, JINST 2012 7 P04008; ibid., P07006), a probabilistic formalism was introduced to predict the response of encapsulated type composite germanium detectors like the SPI (spectrometer for INTEGRAL satellite). Predictions for the peak-to-total and peak-to-background ratios are given at 1.3 MeV for the addback mode of operation. The application of the formalism to clover germanium detector is discussed in two separate papers (R. Kshetri, JINST 2012 7 P07008; ibid., P08015). Using the basic approach developed in those papers, for the first time we present a procedure for calculating the peak-to-total ratio of the cluster detector for γ-energies up to 8 MeV. Results are shown for both bare and suppressed detectors as well as for the single crystal and addback modes of operation. We have considered the experimental data of (i) peak-to-total ratio at 1.3 MeV, and (ii) single detector efficiency and addback factor for other energies up to 8 MeV. Using this data, an approximate method of calculating the peak-to-total ratio of other composite detectors, is shown. Experimental validation of our approach (for energies up to 8 MeV) has been confirmed considering the data of the SPI spectrometer. We have discussed about comparisons between various modes of operation and suppression cases. The present paper is the fifth in the series of papers on composite germanium detectors and for the first time discusses about the change in fold distribution and peak-to-total ratio for sophisticated detectors consisting of several modules of miniball, cluster and SPI detectors. Our work could provide a guidance in designing new composite detectors and in performing experimental studies with the existing detectors for high energy gamma-rays.

  1. Determination of total antioxidant capacity by a new spectrophotometric method based on Ce(IV) reducing capacity measurement.

    Science.gov (United States)

    Ozyurt, Dilek; Demirata, Birsen; Apak, Resat

    2007-02-28

    Dietary antioxidants widely found in fruits and vegetables may serve the task of reducing oxidative damage in humans induced by free radicals and reactive oxygen species under 'oxidative stress' conditions. The aim of this work is to develop a simple, low-cost, sensitive, and diversely applicable indirect spectrophotometric method for the determination of total antioxidant capacity of several plants. The method is based on the oxidation of antioxidants with cerium(IV) sulfate in dilute sulfuric acid at room temperature. The Ce(IV) reducing capacity of the sample is measured under carefully adjusted conditions of oxidant concentration and pH such that only antioxidants and not other organic compounds would be oxidized. The spectrophotometric determination of the remaining Ce(IV) was performed after completion of reaction with antioxidants. Quercetin and gallic acid were used as standards for flavonoids and phenolic acids, respectively, and results of antioxidant measurements were reported as trolox equivalents. The developed procedure was successfully applied to the assay of total antioxidant capacity due to simple compounds such as trolox, quercetin, gallic acid, ascorbic acid, catechin, naringin, naringenin, caffeic acid, chlorogenic acid, ferulic acid, and p-coumaric acid, and due to phenolic acids and flavonoids in the arieal parts of nettle (Urtica Dioica L.). Blank correction of significantly absorbing plant extracts at 320nm could be made with the aid of spectrophotometric titration. Plant selection was made in respect to high antioxidant content, and extraction was made with water. The proposed method was reproducible, and the trolox equivalent antioxidant capacities (TEAC coefficients) of the tested antioxidant compounds were correlated to those found by reference methods such as ABTS and CUPRAC. Since the TEAC coefficients found with the proposed method of naringin-naringenin and rutin-catechin pairs were close to each other, this Ce(IV)-based assay

  2. Developing SyrinOX total antioxidant capacity assay for measuring antioxidants in humans.

    Science.gov (United States)

    Prasetyo, Endry N; Knes, Otto; Nyanhongo, Gibson S; Guebitz, Georg M

    2013-02-01

    Accurate monitoring of the antioxidant status or of oxidative stress in patients is still a big challenge in clinical laboratories. This study investigates the possibility of applying a newly developed total antioxidant capacity assay method based on laccase or peroxidase oxidized syringaldazine [Tetramethoxy azobismethylene quinone (TMAMQ)] which is referred to here as SyrinOX, as a diagnostic tool for monitoring both oxidative stress and antioxidant status in patients. Attempts to adapt the Randox total antioxidant procedure [simultaneous incubation of the radical generating system (metmyoglobin and H(2) O(2) ) and antioxidant sample] for SyrinOX were abandoned after it was discovered that the H(2) O(2) reacted with enzymatically generated TMAMQ and ABTS radicals at a rate of 6.4 × 10(-2) /μM/s and 5.7 × 10(-3) /μM/s respectively. Thus this study for the first time demonstrates the negative effects of H(2) O(2) in the Randox system. This leads to erroneous results because the total antioxidant values obtained are the sum of radicals reduced by antioxidants plus those reacting with the radical generating system. Therefore they should be avoided not only for this particular method but also when using other similar methods. Consequently, SyrinOX is best applied using a three-step approach involving, production of TMAMQ, recovery and purification (free from enzyme and other impurities) and then using TMAMQ for measuring the total antioxidant capacity of samples. Using this approach, the reaction conditions for application of SyrinOX when measuring the total antioxidant capacity of plasma sample were determined to be 50% (v/v) ethanol/50 mM sodium succinate buffer pH 5.5, between 20 and 25 °C for at least 1 h. © 2012 The Authors. International Journal of Experimental Pathology © 2012 International Journal of Experimental Pathology.

  3. Low-SNR Capacity of Parallel IM-DD Optical Wireless Channels

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2016-01-01

    The capacity of parallel intensity-modulation and direct-detection (IM-DD) optical wireless channels with total average intensity and per-channel peak intensity constraints is studied. The optimal intensity allocation at low signal-to-noise ratio

  4. Association of serum total antioxidant capacity and total oxidant status with pain perception in patients with myofacial pain dysfunction.

    Science.gov (United States)

    Etoz, Osman A; Ataoglu, Hanife; Erel, Ozcan; Celik, Hakim; Herken, Emine Nur; Bayazit, Yildirim Ahmet

    2009-01-01

    We aimed to find out the association of total antioxidant capacity (TAC) and total oxidant status (TOS) with generalized pressure pain thresholds (PPT) of patients with myofacial pain dysfunction (MPD). PPT scores of patients with MPD (n = 37) and healthy individuals (n = 43) were measured on the hypothenar region of the hand using a mechanical algometer. Serum samples were collected and TAC and TOS were measured by novel methods. The TAC of patients was significantly lower than that of the control subjects. The difference between the TOS measurements of patients and control subjects was not significant. The PPT scores of the patients were significantly lower than that of control subjects. There may be an association between serum antioxidant capacity and MPD. Low serum TAC might also be related with pain perception.

  5. Relation between Silver Nanoparticle Formation Rate and Antioxidant Capacity of Aqueous Plant Leaf Extracts

    Directory of Open Access Journals (Sweden)

    Azat Akbal

    2016-01-01

    Full Text Available Correlation between the antioxidant capacity and silver nanoparticle formation rates of pomegranate (Punica granatum, quince (Cydonia oblonga, chestnut (Castanea sativa, fig (Ficus carica, walnut (Juglans cinerea, black mulberry (Morus nigra, and white mulberry (Morus alba leaf extracts is investigated at a fixed illumination. Silver nanoparticles formed in all plant leaf extracts possess round shapes with average particle size of 15 to 25 nm, whereas corresponding surface plasmon resonance peak wavelengths vary between 422 nm and 451 nm. Cupric reducing antioxidant capacity technique is used as a reference method to determine total antioxidant capacity of the plant leaf extracts. Integrated absorbance over the plasmon resonance peaks exhibits better linear relation with antioxidant capacities of various plant leaf extracts compared to peak absorbance values, with correlation coefficient values of 0.9333 and 0.7221, respectively.

  6. High-capacity cation-exchange column for enhanced resolution of adjacent peaks of cations in ion chromatography.

    Science.gov (United States)

    Rey, M A

    2001-06-22

    One of the advantages of ion chromatography [Anal Chem. 47 (1975) 1801] as compared to other analytical techniques is that several ions may be analyzed simultaneously. One of the most important contributions of cation-exchange chromatography is its sensitivity to ammonium ion, which is difficult to analyze by other techniques [J. Weiss, in: E.L. Johnson (Ed.), Handbook of Ion Chromatography, Dionex, Sunnyvale, CA, USA]. The determination of low concentrations of ammonium ion in the presence of high concentrations of sodium poses a challenge in cation-exchange chromatography [J. Weiss, Ion Chromatography, VCH, 2nd Edition, Weinheim, 1995], as both cations have similar selectivities for the common stationary phases containing either sulfonate or carboxylate functional groups. The task was to develop a new cation-exchange stationary phase (for diverse concentration ratios of adjacent peaks) to overcome limitations experienced in previous trails. Various cation-exchange capacities and column body formats were investigated to optimize this application and others. The advantages and disadvantages of two carboxylic acid columns of different cation-exchange capacities and different column formats will be discussed.

  7. Estimation of folate binding capacity (unsaturated and total) in normal human serum and in β-thalassaemia

    International Nuclear Information System (INIS)

    Moulopoulos, S.; Mantzos, J.; Gyftaki, E.; Kesse-Elias, M.; Alevizou-Terzaki, V.; Souli-Tsimili, E.

    1978-01-01

    A method is described for measuring the total serum folate binding capacity (TBC) after treating the serum with urea at pH5.5, the unsaturated serum folate binding capacity (UBC) being determined without treatment with urea. The method was applied to 50 normal controls and 20 patients with homozygous β-thalassaemia. The results show an increase in folate binding capacity after treating the serum with urea in all cases studied. There is no correlation between serum folic acid level and total or unsaturated folate binding capacity or per cent saturation. The method described is a simple and rapid one for screening the different groups studied for saturated and unsaturated specific folate-binding proteins. (author)

  8. Physical Activity, Aerobic Capacity, and Total Antioxidant Capacity in Healthy Men and in Men with Coronary Heart Disease

    Science.gov (United States)

    Gawron-Skarbek, Anna; Kostka, Joanna; Nowak, Dariusz; Drygas, Wojciech; Jegier, Anna; Kostka, Tomasz

    2015-01-01

    Objective. The purpose of the study was to assess total antioxidant capacity (TAC) of blood serum in relation with habitual leisure time physical activity (LTPA) and aerobic capacity in a group of 90 men with coronary heart disease (CHD) aged 34.8–77.0 years and in 90 age-matched peers without CHD. Methods. Two spectrophotometric methods were applied to assess TAC: Ferric Reducing Ability of Serum (TAC-FRAS) and 2.2-diphenyl-1-picryl-hydrazyl (TAC-DPPH) tests. Aerobic capacity was expressed as physical working capacity at 85% of the maximal heart rate (PWC85%HRmax). Results. CHD patients had higher values of TACFRAS (1.37 ± 0.28 versus 1.27 ± 0.23 mmol FeCl2·L−1; P < 0.05) but there were no group differences for TAC-DPPH and for uric acid (UA). Negative correlation was found between LTPA (also when calculated per kg of body mass) and TAC-DPPH in CHD patients. In CHD patients, TAC-FRAS and UA were lower in subjects with higher aerobic capacity expressed as PWC85%HRmax/kg. Those associations were not found in healthy men. Conclusions. We conclude that TAC of blood serum is moderately adversely related to LTPA and aerobic capacity in patients with CHD. UA, as the main determinant of serum TAC, may be partially responsible for those associations. PMID:26451234

  9. Physical Activity, Aerobic Capacity, and Total Antioxidant Capacity in Healthy Men and in Men with Coronary Heart Disease

    Directory of Open Access Journals (Sweden)

    Anna Gawron-Skarbek

    2015-01-01

    Full Text Available Objective. The purpose of the study was to assess total antioxidant capacity (TAC of blood serum in relation with habitual leisure time physical activity (LTPA and aerobic capacity in a group of 90 men with coronary heart disease (CHD aged 34.8–77.0 years and in 90 age-matched peers without CHD. Methods. Two spectrophotometric methods were applied to assess TAC: Ferric Reducing Ability of Serum (TAC-FRAS and 2.2-diphenyl-1-picryl-hydrazyl (TAC-DPPH tests. Aerobic capacity was expressed as physical working capacity at 85% of the maximal heart rate (PWC85%HRmax. Results. CHD patients had higher values of TACFRAS (1.37±0.28 versus 1.27±0.23 mmol FeCl2·L−1; P<0.05 but there were no group differences for TAC-DPPH and for uric acid (UA. Negative correlation was found between LTPA (also when calculated per kg of body mass and TAC-DPPH in CHD patients. In CHD patients, TAC-FRAS and UA were lower in subjects with higher aerobic capacity expressed as PWC85%HRmax/kg. Those associations were not found in healthy men. Conclusions. We conclude that TAC of blood serum is moderately adversely related to LTPA and aerobic capacity in patients with CHD. UA, as the main determinant of serum TAC, may be partially responsible for those associations.

  10. Low-SNR Capacity of Parallel IM-DD Optical Wireless Channels

    KAUST Repository

    Chaaban, Anas

    2016-11-29

    The capacity of parallel intensity-modulation and direct-detection (IM-DD) optical wireless channels with total average intensity and per-channel peak intensity constraints is studied. The optimal intensity allocation at low signal-to-noise ratio (SNR) is derived, leading to the capacity-achieving onoff keying (OOK) distribution. Interestingly, while activating the strongest channel is optimal if (i) the peak intensity is fixed, this is not the case if (ii) the peak intensity is proportional to the average intensity. The minimum average optical intensity per bit is also studied, and is characterized for case (i) where it is achievable at low SNR. However, in case (ii), the average optical intensity per bit grows indefinitely as SNR decreases, indicating that lower optical intensity per bit can be achieved at moderate SNR than at low SNR.

  11. Serum iron and total iron binding capacity levels among the abo ...

    African Journals Online (AJOL)

    Iron deficiency anaemia is a common tropical disease. Iron plays a very important role in the human body. The understanding of the different blood groups ability to retain iron in their system can give an insight into their ability to handle the disease Iron deficiency anaemia. Serum Iron, Total Iron Binding Capacity (TIBC) and ...

  12. Moderate-Load Muscular Endurance Strength Training Did Not Improve Peak Power or Functional Capacity in Older Men and Women

    Directory of Open Access Journals (Sweden)

    Simon Walker

    2017-09-01

    Full Text Available The present study determined the effects of muscular endurance strength training on maximum strength and power, functional capacity, muscle activation and hypertrophy in older men and women. Eighty-one men and women acted as an intervention group while 22 acted as non-training controls (age range 64–75 y. Intervention training included super-sets (i.e., paired exercises, immediately performing the second exercises following completion of the first with short rest intervals (30–60 s between sets at an intensity of 50–60% one-repetition maximum (1-RM for 15–20 repetitions. Concentric leg press actions measured maximum strength (1-RM and concentric peak power. Functional capacity was assessed by maximum speed walking tests (i.e., forward walk, backward walk, timed-up-and-go, and stair climb tests. Quadriceps muscle activation was assessed by surface electromyogram and twitch interpolation technique. Vastus lateralis cross-sectional area was measured by panoramic ultrasound. Compared to control, the intervention groups increased maximum strength (1-RM; men: 10 ± 7% vs. 2 ± 3%, women: 14 ± 9% vs. 1 ± 6% both P < 0.01 and vastus lateralis cross-sectional area (men: 6 ± 7% vs. −3 ± 6%, women: 10 ± 10% vs. 0 ± 4% both P < 0.05. But there were no between-group differences in peak power, muscle activation or functional capacity (e.g., stair climb; men: −5 ± 7% vs. −4 ± 3%, women: −5 ± 6% vs. −2 ± 5% both P > 0.05. While benefits occurred during muscular endurance strength training, specific stimuli are probably needed to target all aspects of age-related health.

  13. Total peak shape analysis: detection and quantitation of concurrent fronting, tailing, and their effect on asymmetry measurements.

    Science.gov (United States)

    Wahab, M Farooq; Patel, Darshan C; Armstrong, Daniel W

    2017-08-04

    Most peak shapes obtained in separation science depart from linearity for various reasons such as thermodynamic, kinetic, or flow based effects. An indication of the nature of asymmetry often helps in problem solving e.g. in column overloading, slurry packing, buffer mismatch, and extra-column band broadening. However, existing tests for symmetry/asymmetry only indicate the skewness in excess (tail or front) and not the presence of both. Two simple graphical approaches are presented to analyze peak shapes typically observed in gas, liquid, and supercritical fluid chromatography as well as capillary electrophoresis. The derivative test relies on the symmetry of the inflection points and the maximum and minimum values of the derivative. The Gaussian test is a constrained curve fitting approach and determines the residuals. The residual pattern graphically allows the user to assess the problematic regions in a given peak, e.g., concurrent tailing or fronting, something which cannot be easily done with other current methods. The template provided in MS Excel automates this process. The total peak shape analysis extracts the peak parameters from the upper sections (>80% height) of the peak rather than the half height as is done conventionally. A number of situations are presented and the utility of this approach in solving practical problems is demonstrated. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Total Phenolic, Flavonoids and Antioxidant Capacity of Some Medicinal and Aromatic Plants

    Directory of Open Access Journals (Sweden)

    Melinda Nagy

    2014-11-01

    Full Text Available Abstract: Antioxidants are substances that protect cells from the induced oxidative stress damage caused by unstable molecules known as free radicals that. Antioxidants neutralize free radicals as a natural by-product of normal cell processes. In the present study,were evaluated  the phenolic and flavonoids contents as well as the antioxidant capacity of seeds from  the Lamiaceae and Apiaceae family: fennel  (Foeniculum vulgare, dill (Anethum graveolens and rosemary (Rosmarinus officinalis . (Sreemoyee Ch. et. al., 2012 The main objective of the study was the comparative assessment of the phenolic and flavonoid compounds from dill, rosemary and fennel methanolic extracts correlated with their  antioxidant activity. Both total phenolic content and flavonoids content of the seeds samples were measured spectrophotometrically using the Folin-Ciocalteu assay and a chromogenic system of NaNO2–Al(NO33–NaOH, respectively.. Antioxidant capacity was determined by 2,2-DPPH method. Results strongly showed that Rosmarinus officinalis extract has the most effective antioxidant capacity in scavenging DPPH radicals, while Foeniculum vulgare and Anethum graveolens were less active. The total phenolic content was within 773,14 and 3367,24mg GAE/ 100g while the concentration in flavonoids was between 231,84 and 1325,53 QEg/100g dry seeds.  

  15. The total antioxidant capacity and fluorescence imaging of selected plant leaves commonly consumed in Brunei Darussalam

    Science.gov (United States)

    Watu, Aswani; Metussin, Nurzaidah; Yasin, Hartini M.; Usman, Anwar

    2018-02-01

    We investigated the total antioxidant capacity and fluorescence imaging of several selected plants, namely Centella asiatica, Aidia borneensis and Anacardium occidentale, which are grown and traditionally consumed in Brunei Darussalam. The total antioxidant capacities of aqueous-methanolic infusions of their leaves were measured by 2,2-diphenyl-1-picrylhydrazyl (DPPH) free radical scavenging activity, and microscopic fluorescence images were measured to identify the fluorescent substances bound in the leaves. We found that the total antioxidant capacity of their infusions is estimated to be 150, 25, 15 folds, respectively, lower compared with that of the standard gallic acid. Accordingly, we demonstrated that the relative antioxidant activity of young and matured leaves agrees with the intensity of red light emission of their fresh leaves upon UV excitation. Thus, this non-invasive spectroscopic method can be potentially utilized to indicate the antioxidants in plant leaves qualitatively.

  16. Total Antioxidant Capacity and Total Oxidant Status in Saliva of Periodontitis Patients in Relation to Bacterial Load

    Science.gov (United States)

    Zhang, Taowen; Andrukhov, Oleh; Haririan, Hady; Müller-Kern, Michael; Liu, Shutai; Liu, Zhonghao; Rausch-Fan, Xiaohui

    2016-01-01

    The detection of salivary biomarkers has a potential application in early diagnosis and monitoring of periodontal inflammation. However, searching sensitive salivary biomarkers for periodontitis is still ongoing. Oxidative stress is supposed to play an important role in periodontitis progression and tissue destruction. In this cross-sectional study, we investigated total antioxidant capacity (TAC) and total oxidant status (TOS) in saliva of periodontitis patients compared to healthy controls and their relationship with periodontopathic bacteria and periodontal disease severity. Unstimulated saliva was collected from 45 patients with generalized severe periodontitis and 37 healthy individuals and the TAC/TOS were measured. In addition, salivary levels of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola, and Fusobacterium nucleatum in saliva were measured. Salivary TAC was lower in periodontitis patients compared to healthy controls. Moreover, a significant negative correlation of salivary TAC with clinical attachment loss was observed in periodontitis patients. No significant difference in the salivary TOS was observed between periodontitis patients and healthy controls. Bacterial load was enhanced in periodontitis patients and exhibited correlation with periodontal disease severity but not with salivary TAC/TOS. Our data suggest that changes in antioxidant capacity in periodontitis patients are not associated with increased bacterial load and are probably due to a dysregulated immune response. PMID:26779448

  17. Total antioxidant capacity and total oxidant status in saliva of periodontitis patients in relation to bacterial load

    Directory of Open Access Journals (Sweden)

    Taowen eZhang

    2016-01-01

    Full Text Available The detection of salivary biomarkers has a potential application in early diagnosis and monitoring of periodontal inflammation. However, searching sensitive salivary biomarkers for periodontitis is still ongoing. Oxidative stress is supposed to play an important role in periodontitis progression and tissue destruction. In this cross-sectional study, we investigated total antioxidant capacity (TAC and total oxidant status (TOS in saliva of periodontitis patients compared to healthy controls and their relationship with periodontopathic bacteria and periodontal disease severity. Unstimulated saliva was collected from 45 patients with generalized severe periodontitis and 37 healthy individuals and the TAC/TOS were measured. In addition, salivary levels of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola, and Fusobacterium nucleatum in saliva were measured. Salivary TAC was lower in periodontitis patients compared to healthy controls. Moreover, a significant negative correlation of salivary TAC with clinical attachment loss was observed in periodontitis patients. No significant difference in the salivary TOS was observed between periodontitis patients and healthy controls. Bacterial load was enhanced in periodontitis patients and exhibited correlation with periodontal disease severity but not with salivary TAC/TOS. Our data suggest that changes in antioxidant capacity in periodontitis patients are not associated with increased bacterial load and are probably due to a dysregulated immune response.

  18. The role of postural control in the association between aerobic capacity and walking capacity in chronic stroke: a cross-sectional analysis.

    Science.gov (United States)

    Outermans, Jacqueline C; van de Port, Ingrid; Kwakkel, Gert; Visser-Meily, Johanna M; Wittink, Harriet

    2018-03-12

    Reports on the association between aerobic capacity and walking capacity in people after stroke show disparate results. To determine (1) if the predictive validity of peak oxygen uptake (VO2peak) for walking capacity post stroke is different from that of maximal oxygen uptake (VO2max) and (2) if postural control, hemiplegic lower extremity muscle strength, age and gender distort the association between aerobic capacity and walking capacity. Cross-sectional study. General community in Utrecht, the Netherlands. Community-dwelling people more than three months after stroke. Measurement of aerobic capacity were performed with cardiopulmonary exercise testing (CPET) and differentiated between the achievement of VO2peak or VO2max. Measurement of walking capacity with the Six Minute Walk Test (6MWT), postural control with the Performance Oriented Mobility Assessment (POMA) and hemiplegic lower extremity muscle strength with the Motricity Index (MI-LE). Fifty-one out of 62 eligible participants, aged 64.7 (±12.5) years were included. Analysis of covariance (ANCOVA) showed a nonsignificant difference between the predictive validities of VO2max (N = 22, β = 0.56; 95%CI 0.12 - 0.97) and VO2peak (N = 29, β = 0.72; 95%CI 0.38 - 0.92). Multiple regression analysis of the pooled sample showed a significant decrease in the β value of VO2peak (21.6%) for the 6MWT when adding the POMA as a covariate in the association model. VO2peak remained significantly related to 6MWT after correcting for the POMA (β = 0.56 (95%CI 0.39 - 0.75)) CONCLUSIONS: The results suggest similar predictive validity of aerobic capacity for walking capacity in participants achieving VO2max compared to those only achieving VO2peak. Postural control confounds the association between aerobic capacity and walking capacity. Aerobic capacity remains a valid predictor of walking capacity. Aerobic capacity is an important factor associated with walking capacity after stroke. However, to understand this

  19. Decrease of total antioxidant capacity during coronary artery bypass surgery.

    Science.gov (United States)

    Kunt, Alper Sami; Selek, Sahbettin; Celik, Hakim; Demir, Deniz; Erel, Ozcan; Andac, Mehmet Halit

    2006-09-01

    Cardiac surgery induces an oxidative stress, which may lead to impairment of cardiac function. In this study, we aimed to measure the changes of oxidative and antioxidative status of patients undergoing coronary artery bypass surgery (CABG). We studied 79 patients who underwent CABG with and without cardiopulmonary bypass (CPB). Of the 79 patients, 39 had CPB and 40 did not. Blood samples were drawn before, during, and after the surgery. Antioxidant status was evaluated by measuring total antioxidant capacity (TAC), and oxidative status was evaluated by measuring total peroxide (TP) levels and oxidative stress index (OSI). TP and OSI levels increased, while TAC decreased progressively after the beginning of surgery, for all patients. There were negative correlations between TAC levels and aortic cross-clamping period and anastomosis time ( r = -0.553, p antioxidant vitamins such as vitamins C and E may be beneficial for patients undergoing CABG.

  20. Dissociated time course between peak torque and total work recovery following bench press training in resistance trained men.

    Science.gov (United States)

    Ferreira, Diogo V; Gentil, Paulo; Ferreira-Junior, João B; Soares, Saulo R S; Brown, Lee E; Bottaro, Martim

    2017-10-01

    To evaluate the time course of peak torque and total work recovery after a resistance training session involving the bench press exercise. Repeated measures with a within subject design. Twenty-six resistance-trained men (age: 23.7±3.7years; height: 176.0±5.7cm; mass: 79.65±7.61kg) performed one session involving eight sets of the bench press exercise performed to momentary muscle failure with 2-min rest between sets. Shoulder horizontal adductors peak torque (PT), total work (TW), delayed onset muscle soreness (DOMS) and subjective physical fitness were measured pre, immediately post, 24, 48, 72 and 96h following exercise. The exercise protocol resulted in significant pectoralis major DOMS that lasted for 72h. Immediately after exercise, the reduction in shoulder horizontal adductors TW (25%) was greater than PT (17%). TW, as a percentage of baseline values, was also less than PT at 24, 48 and 96h after exercise. Additionally, PT returned to baseline at 96h, while TW did not. Resistance trained men presented dissimilar PT and TW recovery following free weight bench press exercise. This indicates that recovery of maximal voluntary contraction does not reflect the capability to perform multiple contractions. Strength and conditioning professionals should be cautious when evaluating muscle recovery by peak torque, since it can lead to the repetition of a training session sooner than recommended. Copyright © 2017. Published by Elsevier Inc.

  1. Peak Oil, Peak Coal and Climate Change

    Science.gov (United States)

    Murray, J. W.

    2009-05-01

    Research on future climate change is driven by the family of scenarios developed for the IPCC assessment reports. These scenarios create projections of future energy demand using different story lines consisting of government policies, population projections, and economic models. None of these scenarios consider resources to be limiting. In many of these scenarios oil production is still increasing to 2100. Resource limitation (in a geological sense) is a real possibility that needs more serious consideration. The concept of 'Peak Oil' has been discussed since M. King Hubbert proposed in 1956 that US oil production would peak in 1970. His prediction was accurate. This concept is about production rate not reserves. For many oil producing countries (and all OPEC countries) reserves are closely guarded state secrets and appear to be overstated. Claims that the reserves are 'proven' cannot be independently verified. Hubbert's Linearization Model can be used to predict when half the ultimate oil will be produced and what the ultimate total cumulative production (Qt) will be. US oil production can be used as an example. This conceptual model shows that 90% of the ultimate US oil production (Qt = 225 billion barrels) will have occurred by 2011. This approach can then be used to suggest that total global production will be about 2200 billion barrels and that the half way point will be reached by about 2010. This amount is about 5 to 7 times less than assumed by the IPCC scenarios. The decline of Non-OPEC oil production appears to have started in 2004. Of the OPEC countries, only Saudi Arabia may have spare capacity, but even that is uncertain, because of lack of data transparency. The concept of 'Peak Coal' is more controversial, but even the US National Academy Report in 2007 concluded only a small fraction of previously estimated reserves in the US are actually minable reserves and that US reserves should be reassessed using modern methods. British coal production can be

  2. A novel automated direct measurement method for total antioxidant capacity using a new generation, more stable ABTS radical cation.

    Science.gov (United States)

    Erel, Ozcan

    2004-04-01

    To develop a novel colorimetric and automated direct measurement method for total antioxidant capacity (TAC). A new generation, more stable, colored 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid radical cation (ABTS(*+)) was employed. The ABTS(*+) is decolorized by antioxidants according to their concentrations and antioxidant capacities. This change in color is measured as a change in absorbance at 660 nm. This process is applied to an automated analyzer and the assay is calibrated with Trolox. The novel assay is linear up to 6 mmol Trolox equivalent/l, its precision values are lower than 3%, and there is no interference from hemoglobin, bilirubin, EDTA, or citrate. The method developed is significantly correlated with the Randox- total antioxidant status (TAS) assay (r = 0.897, P total antioxidant capacity.

  3. Spatial peak-load pricing

    International Nuclear Information System (INIS)

    Arellano, M. Soledad; Serra, Pablo

    2007-01-01

    This article extends the traditional electricity peak-load pricing model to include transmission costs. In the context of a two-node, two-technology electric power system, where suppliers face inelastic demand, we show that when the marginal plant is located at the energy-importing center, generators located away from that center should pay the marginal capacity transmission cost; otherwise, consumers should bear this cost through capacity payments. Since electric power transmission is a natural monopoly, marginal-cost pricing does not fully cover costs. We propose distributing the revenue deficit among users in proportion to the surplus they derive from the service priced at marginal cost. (Author)

  4. Seminal plasma total antioxidant capacity and vitamin- C levels in asthenozoospermia: a case- control study

    Directory of Open Access Journals (Sweden)

    Ali Bidmeshkipour

    2010-03-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Defective sperm function is now recognized as one of the most important causes of male infertility. Seminal plasma possesses a rich source of different enzymatic and non-enzymatic antioxidants such as vitamin C (ascorbic acid that protect spermatozoa against oxidative stress as one of the mediators of infertility causing sperm dysfunction and low sperm quality. The aim of this study was investigation of seminal total antioxidant capacity and determination of vitamin C effects on sperm motility. "n"nMethods: We designed a case-control study with a total subject of 62 males. Sperm parameters were analyzed according to World Health Organization guidelines (WHO, 1999. Total antioxidant capacity and vitamin C level of seminal plasma were measured in the 32 normozoospermic as the control group and 32 asthenospermic men as the case group using FRAP (Ferric Reducing of Antioxidants Powers and RP-HPLC (Reverse Phase High Performance Liquid Chromatography methods, respectively. "n"nResults: Our results indicated that total antioxidant capacity levels in the seminal plasma of asthenospermic men were significantly lower than healthy men (p=0.002. In addition, we found a positive correlation between reduced total

  5. Total and corrected antioxidant capacity in hemodialyzed patients

    Directory of Open Access Journals (Sweden)

    Margioris Andrew N

    2003-07-01

    Full Text Available Abstract Background Oxidative stress may play a critical role in the vascular disease of end stage renal failure and hemodialysis patients. Studies, analyzing either discrete analytes and antioxidant substances, or the integrated total antioxidant activity of human plasma during hemodialysis, give contradictory results. Methods Recently, we have introduced a new automated method for the determination of Total Antioxidant Capacity (TAC of human plasma. We have serially measured TAC and corrected TAC (cTAC: after subtraction of the interactions due to endogenous uric acid, bilirubin and albumin in 10 patients before the onset of the dialysis session, 10 min, 30 min, 1 h, 2 h and 3 h into the procedure and after completion of the session. Results Our results indicate that TAC decreases, reaching minimum levels at 2 h. However, corrected TAC increases with t1/2 of about 30 min. We then repeated the measurements in 65 patients undergoing dialysis with different filters (36 patients with ethylene vinyl alcohol copolymer resin filter -Eval-, 23 patients with two polysulfone filters -10 with F6 and 13 with PSN140-, and 6 patients with hemophan filters. Three specimens were collected (0, 30, 240 min. The results of this second group confirm our initial results, while no significant difference was observed using either filter. Conclusions Our results are discussed under the point of view of possible mechanisms of modification of endogenous antioxidants, and the interaction of lipid- and water-soluble antioxidants.

  6. Electrochemical sensing of total antioxidant capacity and polyphenol content in wine samples using amperometry online-coupled with microdialysis.

    Science.gov (United States)

    Jakubec, Petr; Bancirova, Martina; Halouzka, Vladimir; Lojek, Antonin; Ciz, Milan; Denev, Petko; Cibicek, Norbert; Vacek, Jan; Vostalova, Jitka; Ulrichova, Jitka; Hrbac, Jan

    2012-08-15

    This work describes the method for total antioxidant capacity (TAC) and/or total content of phenolics (TCP) analysis in wines using microdialysis online-coupled with amperometric detection using a carbon microfiber working electrode. The system was tested on 10 selected wine samples, and the results were compared with total reactive antioxidant potential (TRAP), oxygen radical absorbance capacity (ORAC), and chemiluminescent determination of total antioxidant capacity (CL-TAC) methods using Trolox and catechin as standards. Microdialysis online-coupled with amperometric detection gives similar results to the widely used cyclic voltammetry methodology and closely correlates with ORAC and TRAP. The problem of electrode fouling is overcome by the introduction of an electrochemical cleaning step (1-2 min at the potential of 0 V vs Ag/AgCl). Such a procedure is sufficient to fully regenerate the electrode response for both red and white wine samples as well as catechin/Trolox standards. The appropriate size of microdialysis probes enables easy automation of the electrochemical TAC/TCP measurement using 96-well microtitration plates.

  7. Capacity Bounds for Parallel Optical Wireless Channels

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2016-01-01

    A system consisting of parallel optical wireless channels with a total average intensity constraint is studied. Capacity upper and lower bounds for this system are derived. Under perfect channel-state information at the transmitter (CSIT), the bounds have to be optimized with respect to the power allocation over the parallel channels. The optimization of the lower bound is non-convex, however, the KKT conditions can be used to find a list of possible solutions one of which is optimal. The optimal solution can then be found by an exhaustive search algorithm, which is computationally expensive. To overcome this, we propose low-complexity power allocation algorithms which are nearly optimal. The optimized capacity lower bound nearly coincides with the capacity at high SNR. Without CSIT, our capacity bounds lead to upper and lower bounds on the outage probability. The outage probability bounds meet at high SNR. The system with average and peak intensity constraints is also discussed.

  8. From a single encapsulated detector to the spectrometer for INTEGRAL satellite: predicting the peak-to-total ratio at high gamma-energies

    OpenAIRE

    Kshetri, Ritesh

    2012-01-01

    In two recent papers (R. Kshetri, JINST 2012 7 P04008; ibid., P07006), a probabilistic formalism was introduced to predict the response of encapsulated type composite germanium detectors like the SPI (spectrometer for INTEGRAL satellite). Predictions for the peak-to-total and peak-to-background ratios are given at 1.3 MeV for the addback mode of operation. The application of the formalism to clover germanium detector is discussed in two separate papers (R. Kshetri, JINST 2012 7 P07008; ibid.,...

  9. The French capacity mechanism

    International Nuclear Information System (INIS)

    2014-01-01

    The French capacity mechanism has been design to ensure security of supply in the context of the energy transition. This energy transition challenges the electricity market design with several features: peak load growth, the development of renewables, demand response,... To ensure security of supply in this context, a capacity mechanism is being implemented in France. It is a market wide capacity obligation on electricity suppliers, based on market principles. Suppliers are responsible for forecasting their obligation, which corresponds to their contribution to winter peak load, and must procure enough capacity certificates to meet their obligations. Capacity certificates are granted to capacities through a certification process, which assesses their contribution to security of supply on the basis of availability commitments. This certification process is technology neutral and performance based, associated with controls and penalties in case of non compliance. Demand Side is fully integrated in the market, either through the reduction of suppliers' capacity obligation or direct participation after certification. In addition to the expected benefits in terms of security of supply, the French capacity market will foster the development of demand response. The participation of foreign capacities will require adaptations which are scheduled in a road-map, and could pave the way for further European integration of energy policies. (authors)

  10. Aerobic capacity related to cardiac size in young children

    DEFF Research Database (Denmark)

    Dencker, M; Wollmer, P; Karlsson, M

    2013-01-01

    Aerobic capacity, defined as peak oxygen uptake (VO2PEAK), is generally considered to be the best single marker for aerobic fitness. We assessed if VO2PEAK is related to different cardiac dimensions in healthy young children on a population base.......Aerobic capacity, defined as peak oxygen uptake (VO2PEAK), is generally considered to be the best single marker for aerobic fitness. We assessed if VO2PEAK is related to different cardiac dimensions in healthy young children on a population base....

  11. Market Designs : A Survey and Analysis of Methods to Ensure Peak Capacity

    OpenAIRE

    Gullberg, Erik

    2008-01-01

    The production and consumption of electricity must be in balance in order to maintain the frequency in an electrical grid. During peak loads this may be troublesome to achieve due to lack of adequate production capabilities. Competitive electricity markets with price caps have a problem - insufficient revenues for peak production units which lead to mothballing or decommissioning of power plants. Inadequate production capability is solved through design of the electricity markets which render...

  12. The Effects of Cell Phone Waves (900 MHz-GSM Band) on Sperm Parameters and Total Antioxidant Capacity in Rats.

    Science.gov (United States)

    Ghanbari, Masoud; Mortazavi, Seyed Bagher; Khavanin, Ali; Khazaei, Mozafar

    2013-04-01

    There is tremendous concern regarding the possible adverse effects of cell phone microwaves. Contradictory results, however, have been reported for the effects of these waves on the body. In the present study, the effect of cell phone microwaves on sperm parameters and total antioxidant capacity was investigated with regard to the duration of exposure and the frequency of these waves. This experimental study was performed on 28 adult male Wistar rats (200-250 g). The animals were randomly assigned to four groups (n=7): i. control; ii. two-week exposure to cell phone-simulated waves; iii. three-week exposure to cell phonesimulated waves; and iv. two-week exposure to cell phone antenna waves. In all groups, sperm analysis was performed based on standard methods and we determined the mean sperm total antioxidant capacity according to the ferric reducing ability of plasma (FRAP) method. Data were analyzed by one-way ANOVA followed by Tukey's test using SPSS version 16 software. The results indicated that sperm viability, motility, and total antioxidant capacity in all exposure groups decreased significantly compared to the control group (pcell phone waves can decrease sperm viability and motility in rats. These waves can also decrease sperm total antioxidant capacity in rats and result in oxidative stress.

  13. Comparison of different tests used in mapping the Greek virgin olive oil production for the determination of its total antioxidant capacity

    Energy Technology Data Exchange (ETDEWEB)

    Minioti, K. S.; Georgiou, C. A.

    2010-07-01

    This study aims to map the total antioxidant capacity (Tac) of 50 Greek olive oil samples from the 2005-2006 season according to production region and cultivar and to compare the 2, 2'-amino-bis (3-ethylbenzo-thiazoline-6- sulfonic acid (Abets), 2, 2-diphenyl-1-picrylhydrazyl radical (DPPH) and F olin-Ciocalteu tests for use with olive oil. Antioxidant capacities determined in the hydrophilic fraction range between 5.42 - 22.5 mM gallic acid Kg{sup -}1 olive oil for the ABTS method and 1.29 - 9.95 mM Kg{sup -}1 for the DPPH method while in total, olive oil TAC ranges between 77 - 177 mM Kg{sup -}1 as assessed by the DPPH method. The results of total phenol content range between 3.8 and 29.4 mM Kg{sup -}1 olive oil. Total phenol content correlates with total antioxidant capacity assessed in the hydrophilic fraction through the DPPH (r = 0.89) and the ABTS (r = 0.69) assays. The hydrophilic fraction DPPH values correlate significantly with the ABTS values (r = 0.81). However, the DPPH values for total olive oil correlate poorly with the ABTS assay, the Folin-Ciocalteu method and the DPPH assay in hydrophilic fraction. Although total phenolic content shows good correlation with ABTS and DPPH values and could serve as a useful indicator for olive oil antioxidant capacity, the use of a battery of tests contributes to better characterization of the antioxidant capacity of olive oil. (Author) 14 refs.

  14. Low-SNR Capacity of MIMO Optical Intensity Channels

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2017-01-01

    The capacity of the multiple-input multiple-output (MIMO) optical intensity channel is studied, under both average and peak intensity constraints. We focus on low SNR, which can be modeled as the scenario where both constraints proportionally vanish, or where the peak constraint is held constant while the average constraint vanishes. A capacity upper bound is derived, and is shown to be tight at low SNR under both scenarios. The capacity achieving input distribution at low SNR is shown to be a maximally-correlated vector-binary input distribution. Consequently, the low-SNR capacity of the channel is characterized. As a byproduct, it is shown that for a channel with peak intensity constraints only, or with peak intensity constraints and individual (per aperture) average intensity constraints, a simple scheme composed of coded on-off keying, spatial repetition, and maximum-ratio combining is optimal at low SNR.

  15. Low-SNR Capacity of MIMO Optical Intensity Channels

    KAUST Repository

    Chaaban, Anas

    2017-09-18

    The capacity of the multiple-input multiple-output (MIMO) optical intensity channel is studied, under both average and peak intensity constraints. We focus on low SNR, which can be modeled as the scenario where both constraints proportionally vanish, or where the peak constraint is held constant while the average constraint vanishes. A capacity upper bound is derived, and is shown to be tight at low SNR under both scenarios. The capacity achieving input distribution at low SNR is shown to be a maximally-correlated vector-binary input distribution. Consequently, the low-SNR capacity of the channel is characterized. As a byproduct, it is shown that for a channel with peak intensity constraints only, or with peak intensity constraints and individual (per aperture) average intensity constraints, a simple scheme composed of coded on-off keying, spatial repetition, and maximum-ratio combining is optimal at low SNR.

  16. Physical Activity and Adherence to Mediterranean Diet Increase Total Antioxidant Capacity: The ATTICA Study

    Directory of Open Access Journals (Sweden)

    Stavros A. Kavouras

    2011-01-01

    Full Text Available We studied the association of physical activity and adherence to the Mediterranean diet, in total antioxidant capacity (TAC. A random sample of 1514 men and 1528 women was selected from Attica region. Physical activity was assessed with a translated version of the validated “International Physical Activity Questionnaire” (iPAQ, and dietary intake through a validated Food Frequency Questionnaire (FFQ. Adherence to the Mediterranean diet was assessed by the MedDietScore that incorporated the inherent characteristics of this diet. TAC was positively correlated with the degree of physical activity (P<.05. TAC was also positively correlated with MedDietScore (r=0.24, P<.001. Stratified analysis by diet status revealed that the most beneficial results were observed to highly active people as compared to inactive, who also followed the Mediterranean diet (288  ±  70 μmol/L, 230  ±  50 μmol/L, resp., after adjusting for various confounders. Increased physical activity and greater adherence to the Mediterranean diet were associated with increased total antioxidant capacity.

  17. Climate Change Impacts on Peak Electricity Consumption: US vs. Europe.

    Science.gov (United States)

    Auffhammer, M.

    2016-12-01

    It has been suggested that climate change impacts on the electric sector will account for the majority of global economic damages by the end of the current century and beyond. This finding is at odds with the relatively modest increase in climate driven impacts on consumption. Comprehensive high frequency load balancing authority level data have not been used previously to parameterize the relationship between electric demand and temperature for any major economy. Using statistical models we analyze multi-year data from load balancing authorities in the United States of America and the European Union, which are responsible for more than 90% of the electricity delivered to residential, industrial, commercial and agricultural customers. We couple the estimated response functions between total daily consumption and daily peak load with an ensemble of downscaled GCMs from the CMIP5 archive to simulate climate change driven impacts on both outcomes. We show moderate and highly spatially heterogeneous changes in consumption. The results of our peak load simulations, however, suggest significant changes in the intensity and frequency of peak events throughout the United States and Europe. As the electricity grid is built to endure maximum load, which usually occurs on the hottest day of the year, our findings have significant implications for the construction of costly peak generating and transmission capacity.

  18. Flavonoids, total phenolics and antioxidant capacity: comparison between commercial green tea preparations

    Directory of Open Access Journals (Sweden)

    Débora Harumi Kodama

    2010-12-01

    Full Text Available The potential health benefits attributed to green tea and its catechins such as antioxidant effects, cancer chemoprevention, and weight loss have led to a huge increase of green tea products in the food market. The objectives of this work were to analyze and compare these products in terms of phenolic contents and in vitro antioxidant capacity including tea bags, dehydrated leaves, and ready-to-drink preparations after standardization of the infusion preparation procedure. Total phenolics content in 1 cup of the different teas varied from 90 to 341 mg of catechin equivalents, and the highest and the lowest values were both those of the ready-to-drink products. Infusions prepared from tea bags had contents varying from 96 to 201 mg.200 mL-1, and there were no significant differences among batches. The DPPH radical scavenging and the Oxygen Radical Absorbing Capacities (ORAC varied largely among the different tea preparations, from 23 to 131 mmoles of Trolox Equivalents (TE.200 mL-1 (DPPH, and from 1.2 to 5.1 mmoles of TE.200 mL-1 (ORAC, but again there were no differences among infusions or ready-to-drink commercial preparations. However, the antioxidant capacity of ready-to-drink products was partially due to the presence of other non-phenolic compounds such as ascorbic acid

  19. Association of increased total antioxidant capacity and anovulation in nonobese infertile patients with clomiphene citrate-resistant polycystic ovary syndrome.

    Science.gov (United States)

    Verit, Fatma Ferda; Erel, Ozcan; Kocyigit, Abdurrahim

    2007-08-01

    To investigate whether total antioxidant capacity (TAC) could predict the response to ovulation induction to clomiphene citrate (CC) in nonobese women with polycystic ovary syndrome. Prospective longitudinal follow-up study. Academic hospital. Fifty-five nonobese, oligomenorrheic women with polycystic ovary syndrome and normal indices of insulin sensitivity. None. Standard clinical examinations and ultrasonographic and endocrine screening, including FSH, LH, E(2), P, total T, sex hormone-binding globulin, DHEAS, and TAC were performed before initiation of CC medication. Within the total group, 27 (49%) of the patients did not ovulate at the end of follow-up. TAC, free androgen index, and ovarian volume were all significantly different in CC nonresponders from those in responders. Total antioxidant capacity was found to be the best predictor in univariate analysis (odds ratio, 171.55; 95% confidence interval, 10.61-2,772.93), and it had the highest area in the receiver operating characteristics analysis (0.91). In a multivariate prediction model, TAC, free androgen index, and ovarian volume showed good predictive power, with Hosmer-Lemeshow goodness of fit test of 0.80. Total antioxidant capacity was the strongest predictor of ovarian response during CC induction of ovulation in these patients. It can be concluded that TAC can be used as a routine screening test.

  20. Peak reduction for commercial buildings using energy storage

    Science.gov (United States)

    Chua, K. H.; Lim, Y. S.; Morris, S.

    2017-11-01

    Battery-based energy storage has emerged as a cost-effective solution for peak reduction due to the decrement of battery’s price. In this study, a battery-based energy storage system is developed and implemented to achieve an optimal peak reduction for commercial customers with the limited energy capacity of the energy storage. The energy storage system is formed by three bi-directional power converter rated at 5 kVA and a battery bank with capacity of 64 kWh. Three control algorithms, namely fixed-threshold, adaptive-threshold, and fuzzy-based control algorithms have been developed and implemented into the energy storage system in a campus building. The control algorithms are evaluated and compared under different load conditions. The overall experimental results show that the fuzzy-based controller is the most effective algorithm among the three controllers in peak reduction. The fuzzy-based control algorithm is capable of incorporating a priori qualitative knowledge and expertise about the load characteristic of the buildings as well as the useable energy without over-discharging the batteries.

  1. Radiologic total lung capacity measurement. Development and evaluation of a computer-based system

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, G.W.; Mazzeo, J.; Borgstrom, M.; Hunter, T.B.; Newell, J.D.; Bjelland, J.C.

    1986-11-01

    The development of a computer-based radiologic total lung capacity (TLC) measurement system designed to be used by non-physician personnel is detailed. Four operators tested the reliability and validity of the system by measuring inspiratory PA and lateral pediatric chest radiographs with a Graf spark pen interfaced to a DEC VAX 11/780 computer. First results suggest that the ultimate goal of developing an accurate and easy to use TLC measurement system for non-physician personnel is attainable.

  2. The validity and reproducibility of food-frequency questionnaire–based total antioxidant capacity estimates in Swedish women

    Science.gov (United States)

    Total antioxidant capacity (TAC) provides an assessment of antioxidant activity and synergistic interactions of redox molecules in foods and plasma. We investigated the validity and reproducibility of food frequency questionnaire (FFQ)–based TAC estimates assessed by oxygen radical absorbance capaci...

  3. Hubbert's Peak -- A Physicist's View

    Science.gov (United States)

    McDonald, Richard

    2011-04-01

    Oil, as used in agriculture and transportation, is the lifeblood of modern society. It is finite in quantity and will someday be exhausted. In 1956, Hubbert proposed a theory of resource production and applied it successfully to predict peak U.S. oil production in 1970. Bartlett extended this work in publications and lectures on the finite nature of oil and its production peak and depletion. Both Hubbert and Bartlett place peak world oil production at a similar time, essentially now. Central to these analyses are estimates of total ``oil in place'' obtained from engineering studies of oil reservoirs as this quantity determines the area under the Hubbert's Peak. Knowing the production history and the total oil in place allows us to make estimates of reserves, and therefore future oil availability. We will then examine reserves data for various countries, in particular OPEC countries, and see if these data tell us anything about the future availability of oil. Finally, we will comment on synthetic oil and the possibility of carbon-neutral synthetic oil for a sustainable future.

  4. Total oxidant status, total antioxidant capacity and ischemia modified albumin levels in children with celiac disease.

    Science.gov (United States)

    Sayar, Ersin; Özdem, Sebahat; Uzun, Gülbahar; İşlek, Ali; Yılmaz, Aygen; Artan, Reha

    2015-01-01

    In our study, we aimed to investigate ischemia modified albumin (IMA) as an oxidative stress marker, as well as other oxidant and antioxidant markers that have not been evaluated in children with celiac disease. A total of 37 pediatric patients who were diagnosed with celiac disease (CD) and 29 healthy children were enrolled in this prospective study. We evaluated the IMA, total oxidant status, total antioxidant capacity, sulfhydryl, and advanced oxidation protein products in all of the subjects. We also compared the levels at the time of the diagnosis, and following a gluten-free diet (GFD) in the children with CD. While the IMA and the other oxidant marker levels were significantly higher in the patient group compared to the control group, the antioxidant marker levels were found to be significantly lower in the patient group, compared to the control group. We also determined that the tissue transglutaminase IgA showed a highly positive correlation, and that the IMA showed a moderately positive correlation with the Marsh-Oberhuber histopathological stage. Additionally, the IMA and other oxidant marker levels were significantly lower, while the antioxidant marker levels were significantly higher after the GFD, compared to the pre-diet period. We detected that oxidative stress played a role in the pathogenesis of CD, and that this could be evaluated using oxidative stress markers, which would regress after the GFD. We also detected that IMA is a marker that shows a correlation with the histopathological stage, and may be used in the diagnosis.

  5. Skeletal muscle-specific expression of PGC-1α-b, an exercise-responsive isoform, increases exercise capacity and peak oxygen uptake.

    Directory of Open Access Journals (Sweden)

    Miki Tadaishi

    Full Text Available Maximal oxygen uptake (VO(2max predicts mortality and is associated with endurance performance. Trained subjects have a high VO(2max due to a high cardiac output and high metabolic capacity of skeletal muscles. Peroxisome proliferator-activated receptor γ coactivator 1α (PGC-1α, a nuclear receptor coactivator, promotes mitochondrial biogenesis, a fiber-type switch to oxidative fibers, and angiogenesis in skeletal muscle. Because exercise training increases PGC-1α in skeletal muscle, PGC-1α-mediated changes may contribute to the improvement of exercise capacity and VO(2max. There are three isoforms of PGC-1α mRNA. PGC-1α-b protein, whose amino terminus is different from PGC-1α-a protein, is a predominant PGC-1α isoform in response to exercise. We investigated whether alterations of skeletal muscle metabolism by overexpression of PGC-1α-b in skeletal muscle, but not heart, would increase VO(2max and exercise capacity.Transgenic mice showed overexpression of PGC-1α-b protein in skeletal muscle but not in heart. Overexpression of PGC-1α-b promoted mitochondrial biogenesis 4-fold, increased the expression of fatty acid transporters, enhanced angiogenesis in skeletal muscle 1.4 to 2.7-fold, and promoted exercise capacity (expressed by maximum speed by 35% and peak oxygen uptake by 20%. Across a broad range of either the absolute exercise intensity, or the same relative exercise intensities, lipid oxidation was always higher in the transgenic mice than wild-type littermates, suggesting that lipid is the predominant fuel source for exercise in the transgenic mice. However, muscle glycogen usage during exercise was absent in the transgenic mice.Increased mitochondrial biogenesis, capillaries, and fatty acid transporters in skeletal muscles may contribute to improved exercise capacity via an increase in fatty acid utilization. Increases in PGC-1α-b protein or function might be a useful strategy for sedentary subjects to perform exercise

  6. Changes in iron levels, total iron binding capacity, transferrin saturation in race horses, before and after of physical exercise

    Directory of Open Access Journals (Sweden)

    Gláucia Abramovitc

    2014-09-01

    Full Text Available ABSTRACT. Abramovitc G., Parra A.C. & Fernandes W.R. [Changes in iron levels, total iron binding capacity, transferrin saturation in race horses, before and after of physical exercise]. Variação de níveis séricos de ferro, da capacidade total de ligação do ferro e da saturação da transferrina em equinos de corrida, antes e após exercício físico. Revista Brasileira de Medicina Veterinária, 36(3:289-293, 2014. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Rua Prof. Dr. Orlando Marques de Paiva 87, Cidade Universitária, Butantã, São Paulo, SP 05508-270, Brasil. Email: wilsonrf@usp.br The preparation of the horse for physical activities in competition is directly related to important factors such as nutrition, muscle adaptation and blood profile, related to the concentration of serum iron, total capacity total iron binding capacity (TIBC and saturation of transferrin. This study aimed to evaluate the influence of exercise in iron levels, the total iron and transferrin saturation in race horses. One hundred and eleven samples of blood serum were collected from Thoroughbred horses, from the Jockey Club of São Paulo, aged between 3 and 4 years old, male and female, clinically healthy, practitioners turf competition, in sand or grass. The samples were obtained before exercise (control time and 30 minutes after exercise (post exercise. These animals were submitted to gallop training, of high intensity and short duration for this research. As a result, it was observed that the serum concentration of iron (Fe showed a statistically significant lowering post-exercise, due to organic re-balance of iron, while TIBC (total iron binding capacity showed a clear and significant increase in their serum levels due to increased needs of iron during and after exercise. The percentage of transferrin saturation in serum was shown to be lower post-exercise, probably due to the recruitment of

  7. Representation of Solar Capacity Value in the ReEDS Capacity Expansion Model

    Energy Technology Data Exchange (ETDEWEB)

    Sigrin, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sullivan, P. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ibanez, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-03-01

    An important issue for electricity system operators is the estimation of renewables' capacity contributions to reliably meeting system demand, or their capacity value. While the capacity value of thermal generation can be estimated easily, assessment of wind and solar requires a more nuanced approach due to the resource variability. Reliability-based methods, particularly assessment of the Effective Load-Carrying Capacity, are considered to be the most robust and widely-accepted techniques for addressing this resource variability. This report compares estimates of solar PV capacity value by the Regional Energy Deployment System (ReEDS) capacity expansion model against two sources. The first comparison is against values published by utilities or other entities for known electrical systems at existing solar penetration levels. The second comparison is against a time-series ELCC simulation tool for high renewable penetration scenarios in the Western Interconnection. Results from the ReEDS model are found to compare well with both comparisons, despite being resolved at a super-hourly temporal resolution. Two results are relevant for other capacity-based models that use a super-hourly resolution to model solar capacity value. First, solar capacity value should not be parameterized as a static value, but must decay with increasing penetration. This is because -- for an afternoon-peaking system -- as solar penetration increases, the system's peak net load shifts to later in the day -- when solar output is lower. Second, long-term planning models should determine system adequacy requirements in each time period in order to approximate LOLP calculations. Within the ReEDS model we resolve these issues by using a capacity value estimate that varies by time-slice. Within each time period the net load and shadow price on ReEDS's planning reserve constraint signals the relative importance of additional firm capacity.

  8. Total phenolics, antioxidant capacity, colour and drying characteristics of date fruit dried with different methods

    Directory of Open Access Journals (Sweden)

    Gökçen İZLİ

    2016-01-01

    Full Text Available Abstract Date slices were dried with the three drying methods convective (60, 70 and 80 °C, microwave (120 W and freeze drying to determine drying characteristics and to compare the dried fruit quality. All colour parameters changed depending on the drying method and colours closest to the fresh sample were obtained with freeze drying. It is interesting to note that the total phenolic content and antioxidant capacity in each sample rose when looked at in relation to the fresh sample. In particular, microwave-dried samples were recorded as having the highest total phenolic content and the highest antioxidant capacity. To explain the drying kinetics of the date slices, nine thin-layer drying models were also attempted. Based on statistical tests, the model developed by Midilli et al. model was found to be the best model for convective and microwave drying, but the Two Term model was the best for freeze drying. This study shows that microwave drying can produce high quality date slices with the additional advantage of reduced drying times compared to convective and freeze drying.

  9. Determination of fruit characteristics, fatty acid profile and total antioxidant capacity of Mespilus germanica L. fruit

    Directory of Open Access Journals (Sweden)

    Hale Seçilmiş Canbay

    2015-11-01

    Full Text Available Objective: To determine fruit characteristics, fatty acid profile and total antioxidant capacitiy of first cultured Mespilus germanica L. Methods: A total of 15 fruits were taken randomly from four directions of adult trees. Then the physical and chemical properties of first cultured medlar fruit (Istanbul/Turkey were measured by using refractometer, colorimeter, spectrophotometer and gas chromatograph mass spectrometer, respectivly. Results: In the fruit studied, the results showed that palmitic acid, stearic acid, oleic acid, linoleic acid, linolenic acid, arachidic acid and behenic acid were the most abundant fatty acids (FAs, and the main FA was palmitic acid [(35.35 ± 1.20%]. The percentage of linoleic acid and stearic acid in this fruit oil were (29.10 ± 1.70% and (8.53 ± 0.25%, respectively. As a result of the analysis, the total antioxidant capacity of medlar fruit was (1.1 ± 0.2 mmol trolox equivalents/L. Conclusions: The present study has demonstrated the concentrations of FAs and the antioxidantive capacity of first cultured Istanbul medlar fruits by using many tested methods. It is proved that in our daily life, medlar fruit plays a significant role with its nutrition and health effect.

  10. Total antioxidant capacity and total oxidant status of synovial fluids in patients with temporomandibular joint pain and dysfunction.

    Science.gov (United States)

    Etöz, Osman A; Akçay, Hüseyin; Neşelioğlu, Salim; Erel, Özcan; Alkan, Alper

    2012-12-01

    The objective of this study was to investigate whether a relationship exists between total antioxidant capacity (TAC) and total oxidant status (TOS) of synovial fluids (SFs) of temporomandibular joint (TMJ) pain patients with pain and dysfunction. Forty-two patients with TMJ pain were included in this study. TAC and TOS values of SFs were measured with a novel colorimetric method. Independent t test and correlations were used to analyze the data. TAC of SFs in patients with TMJ pain and limited mouth opening (LMO; n = 21) were significantly lower (P = 0.03) than patients without LMO (n = 21). TOS of SF was negatively correlated with duration of the disease. There was no correlation between TAC, TOS, and VAS scores of the patients as well as age and maximum mouth opening values. Antioxidant response to oxidative changes (TAC and TOS) in SF decreased as the stage of dysfunction increased. Local administration of antioxidant agents might be considered in management of TMJ pain and dysfunction to prevent possible increased oxidative stress.

  11. Free-space optical communications with peak and average constraints: High SNR capacity approximation

    KAUST Repository

    Chaaban, Anas; Morvan, Jean-Marie; Alouini, Mohamed-Slim

    2015-01-01

    . Numerical evaluation shows that this capacity lower bound is nearly tight at high signal-to-noise ratio (SNR), while it is shown analytically that the gap to capacity upper bounds is a small constant at high SNR. In particular, the gap to the high

  12. The impact of drying techniques on phenolic compound, total phenolic content and antioxidant capacity of oat flour tarhana.

    Science.gov (United States)

    Değirmencioğlu, Nurcan; Gürbüz, Ozan; Herken, Emine Nur; Yıldız, Aysun Yurdunuseven

    2016-03-01

    In this study, the changes in phenolic composition, total phenolic content, and antioxidant capacity of tarhanas supplemented with oat flour (OF) at the levels of 20-100% (w/w) after three drying treatments (sun-, oven-, and microwave drying) were investigated. A total of seventeen phenolic standards have been screened in tarhanas, and the most abundant flavonol and phenolic acid compounds were kaempferol (23.62mg/g) and 3-hydroxy-4-metoxy cinnamic acid (9.60mg/g). The total phenolic content amount gradually increased with the addition of OF to tarhana, but decidedly higher total phenolic content was found in samples oven dried at 55°C as compared with other methods. The microwave- and oven dried tarhana samples showed higher TEACDPPH and TEACABTS values than those dried with the other methods, respectively, in higher OF amounts. Consequently, oven- and microwave-drying can be recommended to retain the highest for phenolic compounds as well as maximal antioxidant capacity in OF supplemented tarhana samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. A peaking-regulation-balance-based method for wind & PV power integrated accommodation

    Science.gov (United States)

    Zhang, Jinfang; Li, Nan; Liu, Jun

    2018-02-01

    Rapid development of China’s new energy in current and future should be focused on cooperation of wind and PV power. Based on the analysis of system peaking balance, combined with the statistical features of wind and PV power output characteristics, a method of comprehensive integrated accommodation analysis of wind and PV power is put forward. By the electric power balance during night peaking load period in typical day, wind power installed capacity is determined firstly; then PV power installed capacity could be figured out by midday peak load hours, which effectively solves the problem of uncertainty when traditional method hard determines the combination of the wind and solar power simultaneously. The simulation results have validated the effectiveness of the proposed method.

  14. Maximal exercise capacity in patients with obstructive sleep apnoea syndrome: A systematic review and meta-analysis.

    Science.gov (United States)

    Mendelson, Monique; Marillier, Mathieu; Bailly, Sébastien; Flore, Patrice; Borel, Jean-Christian; Vivodtzev, Isabelle; Doutreleau, Stéphane; Tamisier, Renaud; Pépin, Jean-Louis; Verges, Samuel

    2018-04-26

    Maximal aerobic capacity is a strong health predictor and peak oxygen consumption (VO 2peak ) is considered a reflection of total body health. No systematic reviews or meta-analysis' to date have synthesised the existing data regarding VO 2peak in patients with obstructive sleep apnoea (OSA).A systematic review of English and French articles using Pubmed/Medline and Embase included studies assessing VO 2peak of OSA patients in mL·kg -1 ·min -1 compared with controls or in % predicted. Two independent reviewers analysed the studies, extracted the data and assessed the quality of evidence.Mean VO 2peak expressed in mL·kg -1 ·min -1 was significantly lower in patients with OSA when compared with controls (mean difference=-2.7 mL·kg -1 ·min -1 ; p<0.001; n=850). This reduction in VO 2peak was found to be larger in non-obese patients (BMI<30 kg·m -2 ). Mean VO 2peak in % predicted was 90.7±21.0% in OSA patients (n=643).OSA patients present reduced maximal aerobic capacity, which can be associated with increased cardiovascular risks and reduced survival in certain patient subgroups. Maximal exercise testing can be useful to characterise functional limitation and to evaluate health status in OSA patients. Registration # CRD42017057319. Copyright ©ERS 2018.

  15. Climate change is projected to have severe impacts on the frequency and intensity of peak electricity demand across the United States.

    Science.gov (United States)

    Auffhammer, Maximilian; Baylis, Patrick; Hausman, Catherine H

    2017-02-21

    It has been suggested that climate change impacts on the electric sector will account for the majority of global economic damages by the end of the current century and beyond [Rose S, et al. (2014) Understanding the Social Cost of Carbon: A Technical Assessment ]. The empirical literature has shown significant increases in climate-driven impacts on overall consumption, yet has not focused on the cost implications of the increased intensity and frequency of extreme events driving peak demand, which is the highest load observed in a period. We use comprehensive, high-frequency data at the level of load balancing authorities to parameterize the relationship between average or peak electricity demand and temperature for a major economy. Using statistical models, we analyze multiyear data from 166 load balancing authorities in the United States. We couple the estimated temperature response functions for total daily consumption and daily peak load with 18 downscaled global climate models (GCMs) to simulate climate change-driven impacts on both outcomes. We show moderate and heterogeneous changes in consumption, with an average increase of 2.8% by end of century. The results of our peak load simulations, however, suggest significant increases in the intensity and frequency of peak events throughout the United States, assuming today's technology and electricity market fundamentals. As the electricity grid is built to endure maximum load, our findings have significant implications for the construction of costly peak generating capacity, suggesting additional peak capacity costs of up to 180 billion dollars by the end of the century under business-as-usual.

  16. The association of total antioxidant capacity with sex hormones.

    Science.gov (United States)

    Demirbag, Recep; Yilmaz, Remzi; Erel, Ozcan

    2005-07-01

    Although sex hormones have potential cardioprotective effects, their effects on total antioxidant capacity (TAC) are not very well known. The aim of the study was to evaluate TAC in men who have decreased and normal testosterone levels and in women in menopausal and premenopausal period. Ninety-seven subjects with similar age intervals, men aged <45 years and female aged <50 years, were divided into four groups: 1) 10 men with normal testosterone levels, as control, 2) 36 men with decreased testosterone, 3) 19 women in menopause, surgically induced, and 4) 32 women in premenopausal period. Testosterone and estrogen levels were measured by chemiluminescence assay and TAC were measured by using a more recently developed automated measurement method. The TAC was significantly lower in Group 2 and Group 3 than those of Group 1 and Group 4 (ANOVA, p<0.001). A strong correlation between TAC, and testosterone and estrogen were found (r=0.807, p<0.001; r=0.685, p<0.001, testosterone and estrogen respectively). The observed relationship between sex hormones and TAC may have a role in mechanism of their cardioprotective effect.

  17. Utilising excess minibus-taxi capacity for South African townships tours

    NARCIS (Netherlands)

    Rietjens, S.J.H.; Makoriwa, Collins; de Boer, S.J.

    2006-01-01

    This paper proposes an option for the utilisation of excess off-peak capacity of minibus-taxis in South Africa for township tours. The minibus-taxi system typically faces steep peak loads during rush hours with excess vehicle and person capacity available during off-hours. The advantages of the

  18. Impacts of rising air temperatures on electric transmission ampacity and peak electricity load in the United States

    Science.gov (United States)

    Bartos, Matthew; Chester, Mikhail; Johnson, Nathan; Gorman, Brandon; Eisenberg, Daniel; Linkov, Igor; Bates, Matthew

    2016-11-01

    Climate change may constrain future electricity supply adequacy by reducing electric transmission capacity and increasing electricity demand. The carrying capacity of electric power cables decreases as ambient air temperatures rise; similarly, during the summer peak period, electricity loads typically increase with hotter air temperatures due to increased air conditioning usage. As atmospheric carbon concentrations increase, higher ambient air temperatures may strain power infrastructure by simultaneously reducing transmission capacity and increasing peak electricity load. We estimate the impacts of rising ambient air temperatures on electric transmission ampacity and peak per-capita electricity load for 121 planning areas in the United States using downscaled global climate model projections. Together, these planning areas account for roughly 80% of current peak summertime load. We estimate climate-attributable capacity reductions to transmission lines by constructing thermal models of representative conductors, then forcing these models with future temperature projections to determine the percent change in rated ampacity. Next, we assess the impact of climate change on electricity load by using historical relationships between ambient temperature and utility-scale summertime peak load to estimate the extent to which climate change will incur additional peak load increases. We find that by mid-century (2040-2060), increases in ambient air temperature may reduce average summertime transmission capacity by 1.9%-5.8% relative to the 1990-2010 reference period. At the same time, peak per-capita summertime loads may rise by 4.2%-15% on average due to increases in ambient air temperature. In the absence of energy efficiency gains, demand-side management programs and transmission infrastructure upgrades, these load increases have the potential to upset current assumptions about future electricity supply adequacy.

  19. Antioxidant Capacity and Total Phenolic Content in Fruit Tissues from Accessions of Capsicum chinense Jacq. (Habanero Pepper at Different Stages of Ripening

    Directory of Open Access Journals (Sweden)

    Lizbeth A. Castro-Concha

    2014-01-01

    Full Text Available In the past few years, there has been a renewed interest in studying a wide variety of food products that show beneficial effects on human health. Capsicum is an important agricultural crop, not only because its economic importance, but also for the nutritional values of its pods, mainly due to the fact that they are an excellent source of antioxidant compounds, and also of specific constituents such as the pungent capsaicinoids localized in the placental tissue. This current study was designed to evaluate the antioxidant capacity and total phenolic contents from fruits tissues of two Capsicum chinense accessions, namely, Chak k’an-iik (orange and MR8H (red, at contrasting maturation stages. Results showed that red immature placental tissue, with a Trolox equivalent antioxidant capacity (TEAC value of 55.59 μmols TE g−1 FW, exhibited the strongest total antioxidant capacity using both the 2,2-diphenyl-1-picrylhydrazyl (DPPH and the CUPRAC methods. Placental tissue also had the highest total phenolic content (27 g GAE 100 g−1 FW. The antioxidant capacity of Capsicum was directly related to the total amount of phenolic compounds detected. In particular, placentas had high levels of capsaicinoids, which might be the principal responsible for their strong antioxidant activities.

  20. Antioxidant Capacity and Total Phenolic Content in Fruit Tissues from Accessions of Capsicum chinense Jacq. (Habanero Pepper) at Different Stages of Ripening

    Science.gov (United States)

    Tuyub-Che, Jemina; Moo-Mukul, Angel; Vazquez-Flota, Felipe A.; Miranda-Ham, Maria L.

    2014-01-01

    In the past few years, there has been a renewed interest in studying a wide variety of food products that show beneficial effects on human health. Capsicum is an important agricultural crop, not only because its economic importance, but also for the nutritional values of its pods, mainly due to the fact that they are an excellent source of antioxidant compounds, and also of specific constituents such as the pungent capsaicinoids localized in the placental tissue. This current study was designed to evaluate the antioxidant capacity and total phenolic contents from fruits tissues of two Capsicum chinense accessions, namely, Chak k'an-iik (orange) and MR8H (red), at contrasting maturation stages. Results showed that red immature placental tissue, with a Trolox equivalent antioxidant capacity (TEAC) value of 55.59 μmols TE g−1 FW, exhibited the strongest total antioxidant capacity using both the 2,2-diphenyl-1-picrylhydrazyl (DPPH) and the CUPRAC methods. Placental tissue also had the highest total phenolic content (27 g GAE 100 g−1 FW). The antioxidant capacity of Capsicum was directly related to the total amount of phenolic compounds detected. In particular, placentas had high levels of capsaicinoids, which might be the principal responsible for their strong antioxidant activities. PMID:24683361

  1. Decreased total antioxidant capacity and increased oxidative stress in passive smoker infants and their mothers.

    Science.gov (United States)

    Aycicek, Ali; Erel, Ozcan; Kocyigit, Abdurrahim

    2005-12-01

    Smoking has many adverse health effects in infants and adults. The purpose of the study was to study the effect of passive cigarette smoking on oxidative and antioxidative status of plasma in passive smoker infants and their mothers and to compare with those of non-smokers. Subjects were randomly chosen from infants aged 8-26 weeks and their mothers aged 20-34 years. Passive smoker infants (n = 29) and their mothers (n = 29) were defined as having other family members who smoked six or more cigarettes per day continually for at least 8 weeks. Non-smokers were defined as infants (n = 30) and their mothers (n = 24) who had never been exposed to passive smoking. The antioxidative status of plasma were perused by measuring the total antioxidant capacity. Oxidative status was evaluated by predicating total peroxide level, oxidative stress index, protein oxidation and lipid peroxidation. Plasma concentrations of total antioxidant capacity were significantly lower in passive smoker infants and their mothers than non-passive smoker infants and their mothers. However, lipid peroxidation and oxidative stress index were remarkably higher in passive smoker infants and their mothers than those of non-passive smoker infants and their mothers. There were significant correlations between the oxidative and antioxidative parameters of the passive smoker infants and their mothers. Oxidants are increased and antioxidants are decreased in passive smoker infants and their mothers than those of non-smokers. Passive smoker infants and their mothers are exposed to potent oxidative stress.

  2. The relationship of aerobic capacity, anaerobic peak power and experience to performance in CrossFit exercise.

    Science.gov (United States)

    Bellar, D; Hatchett, A; Judge, L W; Breaux, M E; Marcus, L

    2015-11-01

    CrossFit is becoming increasingly popular as a method to increase fitness and as a competitive sport in both the Unites States and Europe. However, little research on this mode of exercise has been performed to date. The purpose of the present investigation involving experienced CrossFit athletes and naïve healthy young men was to investigate the relationship of aerobic capacity and anaerobic power to performance in two representative CrossFit workouts: the first workout was 12 minutes in duration, and the second was based on the total time to complete the prescribed exercise. The participants were 32 healthy adult males, who were either naïve to CrossFit exercise or had competed in CrossFit competitions. Linear regression was undertaken to predict performance on the first workout (time) with age, group (naïve or CrossFit athlete), VO2max and anaerobic power, which were all significant predictors (p CrossFit experience as a significant predictor (p CrossFit competition is a key component of performance in CrossFit workouts which are representative of those performed in CrossFit, and that, in at least one these workouts, aerobic capacity and anaerobic power are associated with success.

  3. The Effects of Cell Phone Waves (900 MHz-GSM Band on Sperm Parameters and Total Antioxidant Capacity in Rats

    Directory of Open Access Journals (Sweden)

    Masoud Ghanbari

    2013-01-01

    Full Text Available Background: There is tremendous concern regarding the possible adverse effects of cellphone microwaves. Contradictory results, however, have been reported for the effectsof these waves on the body. In the present study, the effect of cell phone microwaves onsperm parameters and total antioxidant capacity was investigated with regard to the durationof exposure and the frequency of these waves.Materials and Methods: This experimental study was performed on 28 adult male Wistarrats (200-250 g. The animals were randomly assigned to four groups (n=7: i. control; ii.two-week exposure to cell phone-simulated waves; iii. three-week exposure to cell phonesimulatedwaves; and iv. two-week exposure to cell phone antenna waves. In all groups,sperm analysis was performed based on standard methods and we determined the meansperm total antioxidant capacity according to the ferric reducing ability of plasma (FRAPmethod. Data were analyzed by one-way ANOVA followed by Tukey’s test using SPSSversion 16 software.Results: The results indicated that sperm viability, motility, and total antioxidant capacityin all exposure groups decreased significantly compared to the control group (p<0.05.Increasing the duration of exposure from 2 to 3 weeks caused a statistically significantdecrease in sperm viability and motility (p<0.05.Conclusion: Exposure to cell phone waves can decrease sperm viability and motility inrats. These waves can also decrease sperm total antioxidant capacity in rats and result inoxidative stress.

  4. Further Development of the Nordic Electricity Market - a Common Solution for Investments in Transmission, Congestion Management and Peak Load Capacity

    International Nuclear Information System (INIS)

    Granstroem, Per-Olof

    2005-06-01

    The Nordic market fits well into place as a regional market in the over all European development, and it is therefore necessary to change the perspectives from a national one to a common Nordic approach. Despite the fact that the Nordic market is seen as a success, significant further improvements for customers and society can be made through deeper Nordic integration. The ongoing work on the Nordic electricity market within the Nordic Council of Ministers is therefore very welcomed and the Nordel report 'Enhancing Efficient Functioning of the Nordic Electricity Market' constitutes a good basis material for the further development of the market. There is a need to accelerate the pace of the harmonisation process, by making a clear timetable and prioritisation for the further work. Key issues for the next step are: Harmonisation of the legal framework and hence intensified co-operation among the Nordic governments; Implementation of the five known transmission investments, including a cost-benefit analysis; A more precise definition of the TSO responsibilities and core businesses, including operational reserves a prerequisite for further work on, e.g. the peak load issue; Initiation of cost-benefit analysis concerning future transmission investments; Guaranteed cross border capacity for market players; An analysis on settlement of imbalances and how this is affecting the peak load issue

  5. Preliminary studies of the total cation exchange capacity of sediments from two North Atlantic study sites

    International Nuclear Information System (INIS)

    Hydes, D.J.; Hill, N.C.; Clarke, H.; Carpenter, M.S.N.

    1983-01-01

    Initially four different methods of measuring total cation exchange capacity were compared. There were two chemical methods (ammonium saturation with displacement into seawater, and barium saturation followed by replacement with magnesium) and two radiochemical methods (sodium-22 and caesium-134 saturation). The barium-magnesium and sodium-22 methods were then applied to sediment samples from Core D10164Pound1K from the Nares Fracture Valley, and Core D10554Pound11K from the eastern flank of the Great Meteor Rise. The material at site 10164 is a pelagic clay whereas at site 10554 it is carbonate ooze. The total cation exchange capacities (T.C.E.C.) of samples from the two sites are similar when measured by the sodium-22 method, the mean for Core 10164 was 21.7 meq/100g and 24.4 meq/100g for Core 10554. However for Core 10554 the barium-magnesium method gives a mean of 42.8 meq/100g. The difference in T.C.E.C. measured by the two methods appears to be due to the high calcite content of core 10554 sediment. Measured exchange capacities are lower than in coastal sediments. In deep sea sediments organic matter either makes a very small contribution to the T.C.E.C. (core 10164) or actually blocks exchange sites (Core 10554). Amorphous oxides of iron and manganese contribute between 20 and 50% of the T.C.E.C. (author)

  6. Antioxidant capacity and total phenolic contents of oregano (Origanum vulgare), lavender (Lavandula angustifolia) and lemon balm (Melissa officinalis) from Romania.

    Science.gov (United States)

    Spiridon, Iuliana; Colceru, Svetlana; Anghel, Narcis; Teaca, Carmen Alice; Bodirlau, Ruxanda; Armatu, Alice

    2011-10-01

    The study reported here presents a comparative screening of three medicinal plants including oregano (Origanum vulgare L.), lavender (Lavandula angustifolia) and lemon balm (Melissa officinalis) having the same geographical origin, the Southeast region of Romania, and growing in the same natural conditions. The contents of total phenolics and total flavonoids for the extracts of these were determined. Furthermore, the total antioxidant capacity was also evaluated. It was found that Origanum vulgare and Melissa officinalis extracts present the most effective antioxidant capacity in scavenging DPPH radicals, while Lavandula angustifolia is less active. High performance liquid chromatography-mass spectrometry analysis was used to identify the components of extracts. Major phenolic acids identified in the analysed species were ferulic, rosmarinic, p-coumaric and caffeic, while predominant flavonoids were quercetin, apigenin kaempherol, which were present as glucosides.

  7. Effect of dental restorative materials on total antioxidant capacity and calcium concentration of unstimulated saliva.

    Science.gov (United States)

    Ramezani, Gholam H; Moghadam, Mona-Momeni; Saghiri, Mohammad-Ali; Garcia-Godoy, Franklin; Asatourian, Armen; Aminsobhani, Mohsen; Scarbecz, Mark; Sheibani, Nader

    2017-01-01

    To evaluate the effect of dental amalgam and composite restorations on total antioxidant capacity (TAC) and calcium (Ca) ion concentration of unstimulated saliva. Forty-eight children aged 6-10 years selected and divided into three groups of sixteen (8 males, 8 females). In group A and B, samples consisted of two class II dental composite or amalgam restorations, while in group C samples were caries-free (control group). Unstimulated saliva from all samples was collected and TAC was measured by spectrophotometry using an adaptation of 2, 2'-azino-di-(3-ethylbenzthiazoline-6-sulphonate) (ABTS) assay. The Ca ion level was estimated by an auto- analyzer. Data were analyzed with one- and two-way ANOVA test, at a p difference between groups ( p differences within and between groups ( p Gender is an effective factor in changes induced in oral cavity as females showed more emphatic reaction to dental filling materials than males. Patients who have dental restorations, especially dental composites, should pay more attention to their dental hygiene, because dental restorations can increase oxidative stress and decrease Ca ion level in saliva, which might jeopardize remineralization process of tooth structures after demineralization. Key words: Amalgam, caries, composite, saliva, total antioxidant capacity.

  8. Effect of sulfite treatment on total antioxidant capacity, total oxidant status, lipid hydroperoxide, and total free sulfydryl groups contents in normal and sulfite oxidase-deficient rat plasma.

    Science.gov (United States)

    Herken, Emine Nur; Kocamaz, Erdogan; Erel, Ozcan; Celik, Hakim; Kucukatay, Vural

    2009-08-01

    Sulfites, which are commonly used as preservatives, are continuously formed in the body during the metabolism of sulfur-containing amino acids. Sulfite oxidase (SOX) is an essential enzyme in the pathway of the oxidative degradation of sulfite to sulfate protecting cells from sulfite toxicity. This article investigated the effect of sulfite on total antioxidant capacity (TAC), total oxidant status, lipid hydroperoxide (LOOH), and total free sulfydryl groups (-SH) levels in normal and SOX-deficient male albino rat plasma. For this purpose, rats were divided into four groups: control, sulfite-treated, SOX-deficient, and sulfite-treated SOX-deficient groups. SOX deficiency was established by feeding rats a low molybdenum diet and adding to their drinking water 200 ppm tungsten. Sulfite (70 mg/kg) was administered to the animals via their drinking water. SOX deficiency together with sulfite treatment caused a significant increase in the plasma LOOH and total oxidant status levels. -SH content of rat plasma significantly decreased by both sulfite treatment and SOX deficiency compared to the control. There was also a significant decrease in plasma TAC level by sulfite treatment. In conclusion, sulfite treatment affects the antioxidant/oxidant balance of the plasma cells of the rats toward oxidants in SOX-deficient groups.

  9. Reductions in labour capacity from heat stress under climate warming

    Science.gov (United States)

    Dunne, John P.; Stouffer, Ronald J.; John, Jasmin G.

    2013-06-01

    A fundamental aspect of greenhouse-gas-induced warming is a global-scale increase in absolute humidity. Under continued warming, this response has been shown to pose increasingly severe limitations on human activity in tropical and mid-latitudes during peak months of heat stress. One heat-stress metric with broad occupational health applications is wet-bulb globe temperature. We combine wet-bulb globe temperatures from global climate historical reanalysis and Earth System Model (ESM2M) projections with industrial and military guidelines for an acclimated individual's occupational capacity to safely perform sustained labour under environmental heat stress (labour capacity)--here defined as a global population-weighted metric temporally fixed at the 2010 distribution. We estimate that environmental heat stress has reduced labour capacity to 90% in peak months over the past few decades. ESM2M projects labour capacity reduction to 80% in peak months by 2050. Under the highest scenario considered (Representative Concentration Pathway 8.5), ESM2M projects labour capacity reduction to less than 40% by 2200 in peak months, with most tropical and mid-latitudes experiencing extreme climatological heat stress. Uncertainties and caveats associated with these projections include climate sensitivity, climate warming patterns, CO2 emissions, future population distributions, and technological and societal change.

  10. Analysis of Power Network for Line Reactance Variation to Improve Total Transmission Capacity

    Directory of Open Access Journals (Sweden)

    Ikram Ullah

    2016-11-01

    Full Text Available The increasing growth in power demand and the penetration of renewable distributed generations in competitive electricity market demands large and flexible capacity from the transmission grid to reduce transmission bottlenecks. The bottlenecks cause transmission congestion, reliability problems, restrict competition, and limit the maximum dispatch of low cost generations in the network. The electricity system requires efficient utilization of the current transmission capability to improve the Available Transfer Capability (ATC. To improve the ATC, power flow among the lines can be managed by using Flexible AC Transmission System (FACTS devices as power flow controllers, which alter the parameters of power lines. It is important to place FACTS devices on suitable lines to vary the reactance for improving Total Transmission Capacity (TTC of the network and provide flexibility in the power flow. In this paper a transmission network is analyzed based on line parameters variation to improve TTC of the interconnected system. Lines are selected for placing FACTS devices based on real power flow Performance Index (PI sensitivity factors. TTC is computed using the Repeated Power Flow (RPF method using the constraints of lines thermal limits, bus voltage limits and generator limits. The reactance of suitable lines, selected on the basis of PI sensitivity factors are changed to divert the power flow to other lines with enough transfer capacity available. The improvement of TTC using line reactance variation is demonstrated with three IEEE test systems with multi-area networks. The results show the variation of the selected lines’ reactance in improving TTC for all the test networks with defined contingency cases.

  11. Plasma total antioxidant capacity is associated with dietary intake and plasma level of antioxidants in postmenopausal women.

    Science.gov (United States)

    Wang, Ying; Yang, Meng; Lee, Sang-Gil; Davis, Catherine G; Kenny, Anne; Koo, Sung I; Chun, Ock K

    2012-12-01

    Increased plasma total antioxidant capacity (TAC) has been associated with a high consumption of fruits and vegetables. However, limited information is available on whether plasma TAC reflects the dietary intake of antioxidants and the levels of individual antioxidants in plasma. By using three different assays, the study aimed to determine if plasma TAC can effectively predict dietary intake of antioxidants and plasma antioxidant status. Forty overweight and apparently healthy postmenopausal women were recruited. Seven-day food records and 12-h fasting blood samples were collected for dietary and plasma antioxidant assessments. Plasma TAC was determined by vitamin C equivalent antioxidant capacity (VCEAC), ferric-reducing ability of plasma (FRAP) and oxygen radical absorbance capacity (ORAC) assays. TAC values determined by VCEAC were highly correlated with FRAP (r=0.79, Pantioxidants and represents more closely the plasma antioxidant levels than ORAC and FRAP. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Plasma Total Antioxidant Capacity and Cardiometabolic Risk in Non-Obese and Clinically Healthy Young Adults.

    Science.gov (United States)

    Costa, Jamille Oliveira; Vásquez, Cecília M Passos; Santana, Gleiciane de Jesus; Silva, Natanael de Jesus; Braz, Juciene de Matos; Jesus, Amélia M Ribeiro de; Silva, Danielle Góes da; Cunha, Luana Celina Seraphim; Barbosa, Kiriaque Barra Ferreira

    2017-07-10

    The oxidative biomarkers play an important role in the genesis of cardiometabolic risk-related processes. To investigate the total antioxidant capacity of plasma and its association with cardiometabolic risk in non-obese and clinically healthy young adults. University students of the state of Sergipe, Brazil, aged between 18 and 25 years, were recruited for this study from May of 2013 and October of 2014. Anthropometric, clinical and biochemical parameters were measured and analyzed using protocols which were previously standardized and described in the literature. The measurement of plasma total antioxidant capacity was based on the ability that all the antioxidants present in the sample (plasma) have to inhibit the oxidation of the oxidizable substrate ABTS (2,2`- Azino-di-[3-ethylbenzthiazoline sulphonate]) to ABTS•+ by metmyoglobin. Approximately 25% of the sample presented more than one component of cardiometabolic risk. Low HDL-cholesterol was the most prevalent component. Compared to absence of components, the subjects with at least one component presented greater body weight and waist circumference, higher levels of diastolic blood pressure and fasting glucose, greater total cholesterol/HDL-c ratio, and lower levels of HDL-c (p literatura. A medida da capacidade antioxidante total do plasma baseou-se na capacidade de todos os antioxidantes presentes na amostra (plasma) em inibir a oxidação do substrato oxidável ABTS (2,2-Azino-bis-(3-etilbenzotiazolina-6-sulfonato) a ABTS•+ pela metamioglobina. Aproximadamente 25% da amostra apresentaram mais de um componente do risco cardiometabólico. Valores baixos de HDL foram o componente mais prevalente. Em comparação à ausência de componentes, os indivíduos com pelo menos um componente apresentou valores mais altos de peso corporal, circunferência da cintura, pressão sanguínea diastólica, glicemia de jejum e razão colesterol total/HDL-c, e valores mais baixos de HDL-c (p < 0,05). A glicemia de jejum

  13. Relationship between vitamin intake and total antioxidant capacity in elderly adults

    Directory of Open Access Journals (Sweden)

    Miriam Lucia Ojeda Arredondo

    2016-06-01

    Full Text Available The consumption of foods high in natural antioxidants, like fruits and vegetables, is associated with a lower risk of oxidative stress-related diseases. The aim of this study was to establish the relationship between the plasma antioxidant capacity in adults over fifty and their intake of vitamin A, C, and E. We evaluated 118 24-hour recalls of intake of foods. The intake of vitamin A, C, and E was quantified using food composition tables. We quantified plasma phenols using the Folin-Ciocalteu method. The antioxidant capacity was determined using the Trolox Equivalent Antioxidant Capacity (TEAC and Oxygen Radical Absorption Capacity (ORAC methods. Correlation analyses were performed between the studied variables and a positive correlation was found in most cases. However, none of the correlations was statistically significant. In all cases p-value was >0.05. The quantification of nutrient intake is not an adequate predictor of plasma antioxidant capacity in individuals over fifty

  14. Total antioxidant capacity and starch digestibility of muffins baked with rice, wheat, oat, corn and barley flour.

    Science.gov (United States)

    Soong, Yean Yean; Tan, Seow Peng; Leong, Lai Peng; Henry, Jeya Kumar

    2014-12-01

    Muffins are a popular snack consumed in western and emerging countries. Increased glycemic load has been implicated in the aetiology of diabetes. This study examined the starch digestibility of muffins baked with rice, wheat, corn, oat and barley flour. Rapidly digested starch (RDS) was greatest in rice (445 mg/g) and wheat (444 mg/g) muffins, followed by oat (416 mg/g), corn (402 mg/g) and barley (387 mg/g). Total phenolic content was found to be positively correlated with total antioxidative capacity and inversely related to the RDS of muffins. The phenolic content was highest in muffin baked with barley flour (1,687 μg/g), followed by corn (1,454 μg/g), oat (945 μg/g), wheat (705 μg/g), and rice (675 μg/g) flour. Browning was shown not to correlate with free radical scavenging capacity and digestibility of muffins. The presence of high phenolic content and low RDS makes barley muffin an ideal snack to modulate glycemic response. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Supply security and short-run capacity markets for electricity

    International Nuclear Information System (INIS)

    Creti, Anna; Fabra, Natalia

    2007-01-01

    The creation of electricity markets has raised the fundamental question as to whether markets create the right incentives for the provision of the reserves needed to maintain supply security in the short-run, or whether some form of regulation is required. In some states in the US, electricity distributors have been made responsible for providing such reserves by contracting capacity in excess of their forecasted peak demand. The so-called Installed Capacity Markets provide one means of contracting reserves, and are the subject of this paper. Under monopoly as well as under perfect competition, we identify firms' short-run opportunity costs of committing resources in the capacity market and the costs of inducing full capacity commitment. The long-run investment problem is not considered. From a welfare viewpoint, we also compare the desirability of providing reserves either through capacity markets or through the demand side (i.e. power curtailments). At the optimum, capacity obligations equal peak demand (plus expected outages) and the capacity deficiency rate (which serves as a price cap) is set at firms' opportunity costs of providing full capacity commitment. (Author)

  16. Aerobic Capacity as An Indicator in Different Kinds of Sports

    Directory of Open Access Journals (Sweden)

    Goran Ranković

    2010-02-01

    Full Text Available Physical capacity of athletes is an important element of success in sports achievements. Aerobic capacity has been accepted as its major component. Maximal oxygen uptake (VO2max has been regarded by majority of authors as the best indicator of aerobic capacity of an organism, and at the same time, the best indicator of an athlete’s physical capacity. The aim of the investigation was to analyze the aerobic capacity as an indicator of physical capacity of athletes, differences in their aerobic capacity with regard to the kind of sport they are practicing, as well as the differences obtained when compared to physically inactive subjects. The investigation included the determination of absolute and relative VO2max in the total of 66 male examinees. The examinees were divided into two groups of active athletes (football players (n=22 and volleyball players (n=18 of different profiles, while the third group of non-athletes served as control group. Maximal oxygen uptake was determined by performing the Astrand 6 minute cycle test. Peak values of VO2 max were recorded in the group of football players (4,25±0,27 l/min, and they were statistically significantly higher (p<0,001 compared to other examined groups. In the group of volleyball players the oxygen uptake was 3,95±0,18 l/min, while statistically significantly lower values were reported in the group of non-athletes compared to the groups of athletes (p<0,01. A similar ratio of VO2 max values was also shown by the analysis of values expressed in relative units. Our results showed that peak values of VO2 max were obtained in football players, and that football as a sport requires higher degree of endurance compared to volleyball. Having considered the morphological and functional changes which are the consequence of the training process, it can be concluded that VO2 max values are statistically significantly higher in the groups of athletes compared to the group of non-athletes.

  17. Demand Side Management: An approach to peak load smoothing

    Science.gov (United States)

    Gupta, Prachi

    A preliminary national-level analysis was conducted to determine whether Demand Side Management (DSM) programs introduced by electric utilities since 1992 have made any progress towards their stated goal of reducing peak load demand. Estimates implied that DSM has a very small effect on peak load reduction and there is substantial regional and end-user variability. A limited scholarly literature on DSM also provides evidence in support of a positive effect of demand response programs. Yet, none of these studies examine the question of how DSM affects peak load at the micro-level by influencing end-users' response to prices. After nearly three decades of experience with DSM, controversy remains over how effective these programs have been. This dissertation considers regional analyses that explore both demand-side solutions and supply-side interventions. On the demand side, models are estimated to provide in-depth evidence of end-user consumption patterns for each North American Electric Reliability Corporation (NERC) region, helping to identify sectors in regions that have made a substantial contribution to peak load reduction. The empirical evidence supports the initial hypothesis that there is substantial regional and end-user variability of reductions in peak demand. These results are quite robust in rapidly-urbanizing regions, where air conditioning and lighting load is substantially higher, and regions where the summer peak is more pronounced than the winter peak. It is also evident from the regional experiences that active government involvement, as shaped by state regulations in the last few years, has been successful in promoting DSM programs, and perhaps for the same reason we witness an uptick in peak load reductions in the years 2008 and 2009. On the supply side, we estimate the effectiveness of DSM programs by analyzing the growth of capacity margin with the introduction of DSM programs. The results indicate that DSM has been successful in offsetting the

  18. Exercise capacity and all-cause mortality in male veterans with hypertension aged ≥70 years.

    Science.gov (United States)

    Faselis, Charles; Doumas, Michael; Pittaras, Andreas; Narayan, Puneet; Myers, Jonathan; Tsimploulis, Apostolos; Kokkinos, Peter

    2014-07-01

    Aging, even in otherwise healthy subjects, is associated with declines in muscle mass, strength, and aerobic capacity. Older individuals respond favorably to exercise, suggesting that physical inactivity plays an important role in age-related functional decline. Conversely, physical activity and improved exercise capacity are associated with lower mortality risk in hypertensive individuals. However, the effect of exercise capacity in older hypertensive individuals has not been investigated extensively. A total of 2153 men with hypertension, aged ≥70 years (mean, 75 ± 4) from the Washington, DC, and Palo Alto Veterans Affairs Medical Centers, underwent routine exercise tolerance testing. Peak workload was estimated in metabolic equivalents (METs). Fitness categories were established based on peak METs achieved, adjusted for age: very-low-fit, 2.0 to 4.0 METs (n=386); low-fit, 4.1 to 6.0 METs (n=1058); moderate-fit, 6.1 to 8.0 METs (n=495); high-fit >8.0 METs (n=214). Cox proportional hazard models were applied after adjusting for age, body mass index, race, cardiovascular disease, cardiovascular medications, and risk factors. All-cause mortality was quantified during a mean follow-up period of 9.0 ± 5.5 years. There were a total of 1039 deaths or 51.2 deaths per 1000 person-years of follow-up. Mortality risk was 11% lower (hazard ratio, 0.89; 95% confidence interval, 0.86-0.93; Pexercise capacity. When compared with those achieving ≤4.0 METs, mortality risk was 18% lower (hazard ratio, 0.82; 95% confidence interval, 0.70-0.95; P=0.011) for the low-fit, 36% for the moderate-fit (hazard ratio, 0.64; 95% confidence interval, 0.52-0.78; Pexercise capacity is associated with lower mortality risk in elderly men with hypertension. © 2014 American Heart Association, Inc.

  19. The effect of whisky and wine consumption on total phenol content and antioxidant capacity of plasma from healthy volunteers

    DEFF Research Database (Denmark)

    Duthie, GG; Pedersen, M W; PC, Morrice

    1998-01-01

    wine, malt whisky or unmatured 'new make'spirit. Each volunteer participated on three occasions one week apart, consuming one of the beverages each time. Bloodsamples were obtained from the anticubital vein at intervals up to 4h after consumption of the beverages when a urinesample was also obtained....... RESULTS: Within 30 min of consumption of the wine and whisky, there was a similar andsignificant increase in plasma total phenol content and antioxidant capacity as determined by the ferric reducing capacityof plasma (FRAP). No changes were observed following consumption of 'new make' spirit. CONCLUSIONS......OBJECTIVE: To assess whether consumption of 100 ml of whisky or red wine by healthy male subjects increasedplasma total phenol content and antioxidant capacity. DESIGN: A Latin square arrangement to eliminate ordering effectswhereby, after an overnight fast, nine volunteers consumed 100 ml of red...

  20. Repair capacity of mouse lung after total body irradiation alone or combined with cyclophosphamide

    International Nuclear Information System (INIS)

    Safwat, Akmal; Bentzen, Soeren M.; Nielsen, Ole S.; Mahmoud, Hossam K.; Overgaard, Jens

    1996-01-01

    Purpose. Cyclophosphamide (CTX) combined with fractionated total body irradiation (TBI) is frequently used in the conditioning of patients prior to bone marrow transplantation (BMT). This study was performed to investigate the effect of CTX on the repair capacity of lung tissue after TBI in a mouse model for BMT. Materials and methods. TBI was given as a single fraction, 3 fractions in 3 days (Fx 3) or 9 fractions in 3 days (Fx 9) either alone or 24 h after a single dose of CTX. The single fraction TBI was given at either high dose rate (HDR) of 0.71 Gy/min or low dose rate (LDR) of 0.08 Gy/min. All mice were transplanted 4-6 h after the last TBI fraction. Lung damage was assessed using ventilation rate (VR) and lethality between 28 and 180 days. The repair capacity of lung tissue was estimated using the direct analysis method with the probability of reaching the end point described by a logistic formulation of the linear quadratic model. Results. The VR data confirmed the high repair capacity of lung tissue with an α/β ratio of 4.4 Gy though with a wide 95% confidence interval (CI = 0.03-10.5). Giving CTX before fractionated TBI marked reduced the doses needed to cause response in 50% of the animals. The sparing effect of using fractionated TBI was still evident in the combined CTX-TBI schedules. The estimated α/β ratio was 1.6 Gy (CI = 0.01-4.7) which is within the range of values reported after thoracic radiation only. On the other hand, the sparing effect seen in going from single fraction HDR to LDR was completely abolished when CTX was given 24 h before TBI. The same pattern was repeated when lethality between 28-180 days was used. Yet, the use of lethality to estimate lung damage in a TBI model, markedly underestimated the repair capacity. Conclusions. These results confirm the high repair capacity of lung tissue after TBI and emphasize the value of using a specific end point in testing lung damage after TBI. It also shows that there can be a negative

  1. Total contents of phenolics, flavonoids, tannins and antioxidant capacity of selected traditional Ethiopian alcoholic beverages

    Directory of Open Access Journals (Sweden)

    A. Debebe

    2016-02-01

    Full Text Available The aim of this study was to determine the total contents of phenolics, tannins and flavonoids and antioxidant capacity and their relationships in traditional Ethiopian alcoholic beverages. They have been determined utilizing Folin–Ciocalteu assay, aluminum chloride precipitating agent and 2,2-diphenyl-1-picrylhydrazyl (DPPH assay, respectively. The most widely consumed beverages and which have many varieties were selected for this study. These are gesho fermented and non-gesho beverages tella, tej, borde, keribo, birz, korefe and areke. The total phenolic content obtained in gallic acid equivalent (GAE μg mL-1 was: areke (0.2–0.62, tella (10.1–19.1, tej (5.8–9.5, keribo (10.4–14.9, birz (10.5–12.2, korefe (9.2–10.7 and borde (8.4–10.6. The majority of phenolic compounds in the alcoholic beverages are non-tannic and non-flavonoid compounds. The antioxidant capacity obtained in ascorbic acid equivalent (AAE μg mL-1 was: areke (-0.28–284, tella (31.6–201, tej (1.73–73.7, keribo (39.21–90.11, birz (41.95–63.08, korefe (58.25–96.45 and borde (180–217. The variation in the antioxidant activity among the beverages is due to the types and amount of ingredients used, disparity in the preparation process and the types of phenolic compounds found. The relationship between total phenolics and antioxidant activities was investigated using Pearson correlation at 95% confidence level. The results obtained indicate that the non-gesho fermented beverages such as keribo (-0.714, birz (-0.686 and borde (-0.212 have negative antioxidant correlation with the total phenolic, whereas, fermented beverages with gesho such as tella (0.539, tej (0.385 and korefe (0.557 have positive correlations. Areke has an overall positive correlation (0.609, but, the cereal areke which does not have medicinal plants has negative correlation. DOI: http://dx.doi.org/10.4314/bcse.v30i1.3

  2. Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Withers, C. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States); Cummings, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States); Nigusse, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States)

    2016-09-01

    A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

  3. Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Withers, C. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States); Cummings, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States); Nigusse, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States)

    2016-09-08

    A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

  4. Physical features, phenolic compounds, betalains and total antioxidant capacity of coloured quinoa seeds (Chenopodium quinoa Willd.) from Peruvian Altiplano.

    Science.gov (United States)

    Abderrahim, Fatima; Huanatico, Elizabeth; Segura, Roger; Arribas, Silvia; Gonzalez, M Carmen; Condezo-Hoyos, Luis

    2015-09-15

    Physical features, bioactive compounds and total antioxidant capacity (TAC) of coloured quinoa varieties (Chenopodium quinoa Willd.) from Peruvian Altiplano were studied. Quinoa seeds did not show a pure red colour, but a mixture which corresponded to different fractal colour values (51.0-71.8), and they varied from small to large size. Regarding bioactive compounds, total phenolic (1.23-3.24mg gallic acid equivalents/g) and flavonol contents (0.47-2.55mg quercetin equivalents/g) were highly correlated (r=0.910). Betalains content (0.15-6.10mg/100g) was correlated with L colour parameter (r=-0.569), total phenolics (r=0.703) and flavonols content (r=0.718). Ratio of betaxanthins to betacyanins (0.0-1.41) was negatively correlated with L value (r=-0.744). Whereas, high TAC values (119.8-335.9mmol Trolox equivalents/kg) were negatively correlated with L value (r=-0.779), but positively with betalains (r=0.730), as well as with free (r=0.639), bound (r=0.558) and total phenolic compounds (r=0.676). Unexploited coloured quinoa seeds are proposed as a valuable natural source of phenolics and betalains with high antioxidant capacity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Plasma and salivary total antioxidant capacity in healthy controls compared with aggressive and chronic periodontitis patients.

    Science.gov (United States)

    Baser, Ulku; Gamsiz-Isik, Hikmet; Cifcibasi, Emine; Ademoglu, Evin; Yalcin, Funda

    2015-07-01

    To evaluate the plasma and salivary total antioxidant capacity (TAOC) in patients with generalized chronic periodontitis (CP), generalized aggressive periodontitis (AgP), and periodontally healthy controls. This cross-sectional study includes of 88 individuals seeking dental treatment at the Faculty of Dentistry, Istanbul University, Istanbul, Turkey between January 2011 and March 2012. Fifteen AgP patients were compared with 21 healthy controls (C1), while 36 CP patients were compared with 16 healthy controls (C2). Clinical periodontal measurements were recorded, and plasma and saliva samples were collected. The TAOC of the plasma and saliva samples were determined using a commercially available colorimetric kit. The plasma TAOC of both AgP and CP patients was significantly lower for C1 and C2. The salivary TAOC of CP patients was significantly lower for C2, but there was no significant difference between AgP patients and C1. Our results demonstrate that severe periodontitis may be associated with a lower plasma antioxidant capacity. The reduced antioxidant capacity in patients with severe periodontitis, especially with aggressive forms may be an important contributing factor to severe tissue destruction.

  6. Effect of pomegranate supplementation and aerobic training on total antioxidant capacity and lipid peroxidation in overweight men

    Directory of Open Access Journals (Sweden)

    Soheila Rahimifardin

    2014-11-01

    Results: It was found that MDA index decreased in the pomegranate supplementation group compared to placebo group (P=0.016. But, total antioxidant capacity (TAC index in neither of the groups was significant (P=0.72. Conclusion: Results of the study indicate that pomegranate supplementation can reduce MDA derived from lipid peroxidation after 8 week running training in the obese. .

  7. Alveolar gas exchange and tissue oxygenation during incremental treadmill exercise, and their associations with blood O2 carrying capacity

    Directory of Open Access Journals (Sweden)

    Antti-Pekka E. Rissanen

    2012-07-01

    Full Text Available The magnitude and timing of oxygenation responses in highly active leg muscle, less active arm muscle, and cerebral tissue, have not been studied with simultaneous alveolar gas exchange measurement during incremental treadmill exercise. Nor is it known, if blood O2 carrying capacity affects the tissue-specific oxygenation responses. Thus, we investigated alveolar gas exchange and tissue (m. vastus lateralis, m. biceps brachii, cerebral cortex oxygenation during incremental treadmill exercise until volitional fatigue, and their associations with blood O2 carrying capacity in 22 healthy men. Alveolar gas exchange was measured, and near-infrared spectroscopy (NIRS was used to monitor relative concentration changes in oxy- (Δ[O2Hb], deoxy- (Δ[HHb] and total hemoglobin (Δ[tHb], and tissue saturation index (TSI. NIRS inflection points (NIP, reflecting changes in tissue-specific oxygenation, were determined and their coincidence with ventilatory thresholds (anaerobic threshold (AT, respiratory compensation point (RC; V-slope method was examined. Blood O2 carrying capacity (total hemoglobin mass (tHb-mass was determined with the CO-rebreathing method. In all tissues, NIPs coincided with AT, whereas RC was followed by NIPs. High tHb-mass associated with leg muscle deoxygenation at peak exercise (e.g., Δ[HHb] from baseline walking to peak exercise vs. tHb-mass: r = 0.64, p < 0.01, but not with arm muscle- or cerebral deoxygenation. In conclusion, regional tissue oxygenation was characterized by inflection points, and tissue oxygenation in relation to alveolar gas exchange during incremental treadmill exercise resembled previous findings made during incremental cycling. It was also found out, that O2 delivery to less active m. biceps brachii may be limited by an accelerated increase in ventilation at high running intensities. In addition, high capacity for blood O2 carrying was associated with a high level of m. vastus lateralis deoxygenation at peak

  8. Anorexia, functional capacity, and clinical outcome in patients with chronic heart failure: results from the Studies Investigating Co‐morbidities Aggravating Heart Failure (SICA‐HF)

    Science.gov (United States)

    Saitoh, Masakazu; dos Santos, Marcelo R.; Emami, Amir; Ishida, Junichi; Ebner, Nicole; Valentova, Miroslava; Bekfani, Tarek; Sandek, Anja; Lainscak, Mitja; Doehner, Wolfram; Anker, Stefan D.

    2017-01-01

    Abstract Aims We aimed to assess determinants of anorexia, that is loss of appetite in patients with heart failure (HF) and aimed to further elucidate the association between anorexia, functional capacity, and outcomes in affected patients. Methods and results We assessed anorexia status among 166 patients with HF (25 female, 66 ± 12 years) who participated in the Studies Investigating Co‐morbidities Aggravating HF. Anorexia was assessed by a 6‐point Likert scale (ranging from 0 to 5), wherein values ≥1 indicate anorexia. Functional capacity was assessed as peak oxygen uptake (peak VO2), 6 min walk test, and short physical performance battery test. A total of 57 patients (34%) reported any anorexia, and these patients showed lower values of peak VO2, 6 min walk distance, and short physical performance battery score (all P anorexia. A total of 22 patients (13%) died during a mean follow‐up of 22.5 ± 5.1 months. Kaplan‐Meier curves for cumulative survival showed that those patients with anorexia presented higher mortality (Log‐rank test P = 0.03). Conclusions Inflammation, use of loop diuretics, and cachexia are associated with an increased likelihood of anorexia in patients with HF, and patients with anorexia showed impaired functional capacity and poor outcomes. PMID:28960880

  9. Phenolic content and antioxidant capacity of hybrid variety cocoa beans.

    Science.gov (United States)

    Jonfia-Essien, W A; West, G; Alderson, P G; Tucker, G

    2008-06-01

    Cocoa (Theobroma cacao L.) is a major, economically important, international crop and has been associated with several nutritional benefits including high antioxidant capacity. New cocoa hybrids have been developed in Ghana that exhibit resistance to pest damage during storage. The aim of this work was to assess the phenolic content and antioxidant capacity of these new hybrids in comparison to more traditional cocoa varieties. Total extractable phenolics were similar in all the four hybrids tested ranging from 69.9 to 81.6FAEg(-1). These levels were very similar to that extracted from traditional beans (73.8±2.5FAEg(-1)). The "phenolic profile" was determined by HPLC. A total of 25 peaks was observed but there were only minor differences in this profile between traditional and hybrid bean extracts. Antioxidant capacity was determined using the FRAP assay and traditional beans were found to possess 12.4μmolTEg(-1). In comparison the hybrid beans had antioxidant capacities ranging from 21.6 to 45.5μmolTEg(-1), and these were significantly higher than in the traditional beans for three out of the four hybrids. Since the phenolic and antioxidant levels and in these hybrid varieties were either similar to, or higher than, that obtained from traditional beans, the introduction of these new varieties would be unlikely to impact detrimentally on these nutritional components of the beans. Copyright © 2007 Elsevier Ltd. All rights reserved.

  10. Prototype Development of an Implantable Compliance Chamber for a Total Artificial Heart.

    Science.gov (United States)

    Schmitz, Stephanie; Unthan, Kristin; Sedlaczek, Marc; Wald, Felix; Finocchiaro, Thomas; Spiliopoulos, Sotirios; Koerfer, Reiner; Steinseifer, Ulrich

    2017-02-01

    At our institute a total artificial heart is being developed. It is directly actuated by a linear drive in between two ventricles, which comprise membranes to separate the drive and blood flow. A compliance chamber (CC) is needed to reduce pressure peaks in the ventricles and to increase the pump capacity. Therefore, the movement of the membrane is supported by applying a negative pressure to the air volume inside the drive unit. This study presents the development of the implantable CC which is connected to the drive unit of the total artificial hearts (TAH). The anatomical fit of the CC is optimized by analyzing CT data and adapting the outer shape to ensure a proper fit. The pressure peaks are reduced by the additional volume and the flexible membrane of the CC. The validation measurements of change in pressure peaks and flow are performed using the complete TAH system connected to a custom mock circulation loop. Using the CC, the pressure peaks could be damped below 5 mm Hg in the operational range. The flow output was increased by up to 14.8% on the systemic side and 18.2% on the pulmonary side. The described implantable device can be used for upcoming chronic animal trials. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  11. Efficacy of isokinetic exercise on functional capacity and pain in patellofemoral pain syndrome.

    Science.gov (United States)

    Alaca, Ridvan; Yilmaz, Bilge; Goktepe, A Salim; Mohur, Haydar; Kalyon, Tunc Alp

    2002-11-01

    To assess the effect of an isokinetic exercise program on symptoms and functions of patients with patellofemoral pain syndrome. A total of 22 consecutive patients with the complaint of anterior knee pain who met the inclusion criteria were recruited to assess the efficacy of isokinetic exercise on functional capacity, isokinetic parameters, and pain scores in patients with patellofemoral pain syndrome. A total of 37 knees were examined. Six-meter hopping, three-step hopping, and single-limb hopping course tests were performed for each patient with the measurements of the Lysholm scale and visual analog scale. Tested parameters were peak torque, total work, average power, and endurance ratios. Statistical analyses revealed that at the end of the 6-wk treatment period, functional and isokinetic parameters improved significantly, as did pain scores. There was not statistically significant correlation between different groups of parameters. The isokinetic exercise treatment program used in this study prevented the extensor power loss due to patellofemoral pain syndrome, but the improvement in the functional capacity was not correlated with the gained power.

  12. Statins are related to impaired exercise capacity in males but not females.

    Science.gov (United States)

    Bahls, Martin; Groß, Stefan; Ittermann, Till; Busch, Raila; Gläser, Sven; Ewert, Ralf; Völzke, Henry; Felix, Stephan B; Dörr, Marcus

    2017-01-01

    Exercise and statins reduce cardiovascular disease (CVD). Exercise capacity may be assessed using cardiopulmonary exercise testing (CPET). Whether statin medication is associated with CPET parameters is unclear. We investigated if statins are related with exercise capacity during CPET in the general population. Cross-sectional data of two independent cohorts of the Study of Health in Pomerania (SHIP) were merged (n = 3,500; 50% males). Oxygen consumption (VO2) at peak exercise (VO2peak) and anaerobic threshold (VO2@AT) was assessed during symptom-limited CPET. Two linear regression models related VO2peak with statin usage were calculated. Model 1 adjusted for age, sex, previous myocardial infarction, and physical inactivity and model 2 additionally for body mass index, smoking, hypertension, diabetes and estimated glomerular filtration rate. Propensity score matching was used for validation. Statin usage was associated with lower VO2peak (no statin: 2336; 95%-confidence interval [CI]: 2287-2,385 vs. statin 2090; 95%-CI: 2,031-2149 ml/min; P exercise capacity in males but not females. Sex specific effects of statins on cardiopulmonary exercise capacity deserve further research.

  13. Comparison of different tests used in mapping the Greek virgin olive oil production for the determination of its total antioxidant capacity

    Directory of Open Access Journals (Sweden)

    Georgiou, Constantinos A.

    2010-03-01

    Full Text Available This study aims to map the total antioxidant capacity (TAC of 50 Greek olive oil samples from the 2005-2006 season according to production region and cultivar and to compare the 2, 2’-azino-bis (3-ethylbenzo-thiazoline-6- sulfonic acid (ABTS, 2, 2-diphenyl-1-picrylhydrazyl radical (DPPH and Folin-Ciocalteu tests for use with olive oil. Antioxidant capacities determined in the hydrophilic fraction range between 5.42 - 22.5 mM gallic acid Kg-1 olive oil for the ABTS method and 1.29 - 9.95 mM Kg-1 for the DPPH method while in total, olive oil TAC ranges between 77 - 177 mM Kg-1 as assessed by the DPPH method. The results of total phenol content range between 3.8 and 29.4 mM Kg-1 olive oil. Total phenol content correlates with total antioxidant capacity assessed in the hydrophilic fraction through the DPPH (r = 0.89 and the ABTS (r = 0.69 assays. The hydrophilic fraction DPPH values correlate significantly with the ABTS values (r = 0.81. However, the DPPH values for total olive oil correlate poorly with the ABTS assay, the Folin-Ciocalteu method and the DPPH assay in hydrophilic fraction. Although total phenolic content shows good correlation with ABTS and DPPH values and could serve as a useful indicator for olive oil antioxidant capacity, the use of a battery of tests contributes to better characterization of the antioxidant capacity of olive oil.El objetivo de este estudio es el mapeo de la actividad antioxidante total (TAC de 50 aceites de oliva Griego de los años 2005-2006 de acuerdo a su región y cultivar, y se comparan los ensayos del ácido 2, 2’-azino-bis (3-etilbenzo-tiazolina- 6-sulfónico (ABTS, del 2,2-difenil-1-picrlhidrazil radical (DPPH y de Folin-Ciocalteu. La capacidad antioxidante determinada en la fracción hidrofílica varió entre 5.42-22.5 mM de ácido gálico Kg-1 de aceite para el método ABTS y 1.29- 9.95 mM Kg-1 de aceite para el método de DPPH mientras que la TAC del aceite de oliva completo varió entre 77-177 m

  14. Antiproliferative activity in tumor cell lines, antioxidant capacity and total phenolic, flavonoid and tannin contents of Myrciaria floribunda

    Directory of Open Access Journals (Sweden)

    LUIS A.C. TIETBOHL

    Full Text Available ABSTRACT Myrciaria floribunda (H. West ex Willd. O. Berg, Myrtaceae, is a native plant species of the Atlantic Rain Forest, from north to south of Brazil. The lyophilized ethyl acetate extract from the leaves of M. floribunda was investigated for its antiproliferative activity in tumor cell lines, antioxidant capacity and its total phenolic, flavonoid and tannin contents. Antiproliferative activity was tested in vitro against seven human cancer cells and against immortalized human skin keratinocytes line (HaCat, no cancer cell. Antioxidant activity was determined using 1-diphenyl-2-picrylhydrazyl (DPPH radical scavenging and oxygen radical absorbing capacity (ORAC assays and total phenolic, flavonoid and tannin contents were determined by spectrophotometric techniques. Ethyl acetate extract of M. floribunda exhibited antiproliferative activity against cancer cell lines with total growth inhibition (TGI between 69.70 and 172.10 µg/mL. For HaCat cell, TGI value was 213.60 µg/mL. M. floribunda showed a strong antioxidant potential: EC50 of 45.89±0.42 µg/mL and 0.55±0.05 mmol TE/g for DPPH and ORAC, respectively. Total phenolic content was 0.23±0.013g gallic acid equivalents (GAE/g extract and exhibited 13.10±1.60% of tannins content. The content of flavonoid was 24.08±0.44% expressed as rutin equivalents. These results provide a direction for further researches about the antitumoral potential of M. floribunda.

  15. Statistically-Based Comparison of the Removal Efficiencies and Resilience Capacities between Conventional and Natural Wastewater Treatment Systems: A Peak Load Scenario

    Directory of Open Access Journals (Sweden)

    Long Ho

    2018-03-01

    Full Text Available Emerging global threats, such as climate change, urbanization and water depletion, are driving forces for finding a feasible substitute for low cost-effective conventional activated sludge (AS technology. On the other hand, given their low cost and easy operation, nature-based systems such as constructed wetlands (CWs and waste stabilization ponds (WSPs appear to be viable options. To examine these systems, a 210-day experiment with 31 days of peak load scenario was performed. Particularly, we conducted a deliberate strategy of experimentation, which includes applying a preliminary study, preliminary models, hypothetical tests and power analysis to compare their removal efficiencies and resilience capacities. In contrast to comparable high removal efficiencies of organic matter—around 90%—both natural systems showed moderate nutrient removal efficiencies, which inferred the necessity for further treatment to ensure their compliance with environmental standards. During the peak period, the pond treatment systems appeared to be the most robust as they indicated a higher strength to withstanding the organic matter and nitrogen shock load and were able to recover within a short period. However, high demand of land—2.5 times larger than that of AS—is a major concern of the applicability of WSPs despite their lower operation and maintenance (O&M costs. It is also worth noting that initial efforts on systematic experimentation appeared to have an essential impact on ensuring statistically and practically meaningful results in this comparison study.

  16. Transportation cost of nuclear off-peak power for hydrogen production based on water electrolysis

    International Nuclear Information System (INIS)

    Shimizu, Saburo; Ueno, Shuichi

    2004-01-01

    The paper describes transportation cost of the nuclear off-peak power for a hydrogen production based on water electrolysis in Japan. The power could be obtainable by substituting hydropower and/or fossil fueled power supplying peak and middle demands with nuclear power. The transportation cost of the off-peak power was evaluated to be 1.42 yen/kWh when an electrolyser receives the off-peak power from a 6kV distribution wire. Marked reduction of the cost was caused by the increase of the capacity factor. (author)

  17. Capacity Bounds and High-SNR Capacity of MIMO Intensity-Modulation Optical Channels

    KAUST Repository

    Chaaban, Anas

    2018-02-19

    The capacity of the intensity modulation direct detection multiple-input multiple-output channel is studied. Therein, the nonnegativity constraint of the transmit signal limits the applicability of classical schemes, including precoding. Thus, new ways are required for deriving capacity bounds for this channel. To this end, capacity lower bounds are developed in this paper by deriving the achievable rates of two precodingfree schemes: Channel inversion and QR decomposition. The achievable rate of a DC-offset SVD-based scheme is also derived as a benchmark. Then, capacity upper bounds are derived and compared against the lower bounds. As a result, the capacity at high signal-to-noise ratio (SNR) is characterized for the case where the number of transmit apertures is not larger than the number of receive apertures, and is shown to be achievable by the QR decomposition scheme. This is shown for a channel with average intensity or peak intensity constraints. Under both constraints, the high-SNR capacity is approximated within a small gap. Extensions to a channel with more transmit apertures than receive apertures are discussed, and capacity bounds for this case are derived.

  18. Capacity Bounds and High-SNR Capacity of MIMO Intensity-Modulation Optical Channels

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2018-01-01

    The capacity of the intensity modulation direct detection multiple-input multiple-output channel is studied. Therein, the nonnegativity constraint of the transmit signal limits the applicability of classical schemes, including precoding. Thus, new ways are required for deriving capacity bounds for this channel. To this end, capacity lower bounds are developed in this paper by deriving the achievable rates of two precodingfree schemes: Channel inversion and QR decomposition. The achievable rate of a DC-offset SVD-based scheme is also derived as a benchmark. Then, capacity upper bounds are derived and compared against the lower bounds. As a result, the capacity at high signal-to-noise ratio (SNR) is characterized for the case where the number of transmit apertures is not larger than the number of receive apertures, and is shown to be achievable by the QR decomposition scheme. This is shown for a channel with average intensity or peak intensity constraints. Under both constraints, the high-SNR capacity is approximated within a small gap. Extensions to a channel with more transmit apertures than receive apertures are discussed, and capacity bounds for this case are derived.

  19. Antioxidant capacity of Macaronesian traditional medicinal plants.

    Science.gov (United States)

    Tavares, Lucélia; Carrilho, Dina; Tyagi, Meenu; Barata, David; Serra, Ana Teresa; Duarte, Catarina Maria Martins; Duarte, Rui Oliveira; Feliciano, Rodrigo Pedro; Bronze, Maria Rosário; Chicau, Paula; Espírito-Santo, Maria Dalila; Ferreira, Ricardo Boavida; dos Santos, Cláudia Nunes

    2010-04-12

    The use of many traditional medicinal plants is often hampered by the absence of a proper biochemical characterization, essential to identify the bioactive compounds present. The leaves from five species endemic to the Macaronesian islands with recognized ethnobotanical applications were analysed: Apollonias barbujana (Cav.) Bornm., Ocotea foetens (Ainton) Baill, Prunus azorica (Mouill.) Rivas-Mart., Lousã, Fern. Prieto, E. Días, J.C. Costa & C. Aguiar, Rumex maderensis Lowe and Plantago arborescens Poir. subsp. maderensis (Dcne.) A. Hans. et Kunk.. Since oxidative stress is a common feature of most diseases traditionally treated by these plants, it is important to assess their antioxidant capacity and determine the molecules responsible for this capacity. In this study, the antioxidant capacity of these plants against two of the most important reactive species in human body (hydroxyl and peroxyl radicals) was determined. To trace the antioxidant origin total phenol and flavonoid contents as well as the polyphenolic profile and the amount of trace elements were determined. There was a wide variation among the species analysed in what concerns their total leaf phenol and flavonoid contents. From the High Performance Liquid Chromatography (HPLC) electrochemically detected peaks it was possible to attribute to flavonoids the antioxidant capacity detected in A. barbujana, O. foetens, R. maderensis and P. azorica extracts. These potential reactive flavonoids were identified for A. barbujana, R. maderensis and P. azorica. For R. maderensis a high content (7 mg g-1 dry weight) of L-ascorbic acid, an already described antioxidant phytomolecule, was found. A high content in selenomethionine (414.35 microg g-1 dry weight) was obtained for P. arborescens subsp. maderensis extract. This selenocompound is already described as a hydroxyl radical scavenger is reported in this work as also possessing peroxyl radical scavenging capacity. This work is a good illustration of

  20. VO(2peak), myocardial hypertrophy, and myocardial blood flow in endurance-trained men.

    Science.gov (United States)

    Laaksonen, Marko S; Heinonen, Ilkka; Luotolahti, Matti; Knuuti, Juhani; Kalliokoski, Kari K

    2014-08-01

    Endurance training induces cardiovascular and metabolic adaptations, leading to enhanced endurance capacity and exercise performance. Previous human studies have shown contradictory results in functional myocardial vascular adaptations to exercise training, and we hypothesized that this may be related to different degrees of hypertrophy in the trained heart. We studied the interrelationships between peak aerobic power (V˙O2peak), myocardial blood flow (MBF) at rest and during adenosine-induced vasodilation, and parameters of myocardial hypertrophy in endurance-trained (ET, n = 31) and untrained (n = 17) subjects. MBF and myocardial hypertrophy were studied using positron emission tomography and echocardiography, respectively. Both V˙O2peak (P negatively with adenosine-stimulated MBF, but when LV mass was taken into account as a partial correlate, this correlation disappeared. The present results show that increased LV mass in ET subjects explains the reduced hyperemic myocardial perfusion in this subject population and suggests that excessive LV hypertrophy has negative effect on cardiac blood flow capacity.

  1. Measurement of total antioxidant capacity in gingival crevicular fluid and serum in dogs with periodontal disease.

    Science.gov (United States)

    Pavlica, Zlatko; Petelin, Milan; Nemec, Alenka; Erzen, Damjan; Skaleric, Uros

    2004-11-01

    To determine whether gingival crevicular fluid (GCF) and serum total antioxidant capacities (TACs) correlate with the degree of severity of periodontal disease in dogs. 41 Toy and Miniature Poodles. After assessment of the degree of severity of naturally occurring periodontitis, GCF samples from both maxillary fourth premolars and a blood sample were collected from each dog. The condition of the periodontium of the entire dentition and at each site of GCF collection was recorded. Clinical parameters assessed included plaque index, gingival index, and probing depth. Radiographic analysis of alveolar bone level was also performed. Total antioxidant capacity was measured in GCF and serum samples by use of a commercial kit. Dogs with gingivitis and minimal periodontitis had significantly higher TAC in GCF than dogs with advanced periodontitis. Bivariate regression analysis revealed significant negative correlations between TAC in GCF and clinical parameters and age. The TAC in serum was significantly negatively correlated with the degree of gingival inflammation but was not significantly correlated with age. TAC in GCF is related to the degree of severity of periodontal disease in dogs. This is likely the result of release of reactive oxygen species by activated phagocytes and fibroblasts in the inflamed periodontal tissues. The results of our study suggest that the local delivery of antioxidants may be a useful adjunctive treatment for periodontitis in dogs.

  2. Capacidade antioxidante total de óleos vegetais comestíveis: determinantes químicos e sua relação com a qualidade dos óleos Total antioxidant capacity of edible vegetable oils: chemical determinants and associations with oil quality

    Directory of Open Access Journals (Sweden)

    Vanessa Naciuk Castelo-Branco

    2011-02-01

    Full Text Available A capacidade antioxidante total de óleos vegetais comestíveis é determinada por sua composição físico-química e pode estar associada a atributos de qualidade dos óleos, especialmente a sua bioatividade e possivelmente a sua estabilidade oxidativa. Este artigo apresenta os fundamentos dos ensaios de capacidade antioxidante total e avalia criticamente os ensaios aplicáveis na análise de óleos e os pontos críticos nas aplicações dos ensaios para a análise dessas amostras. Discute-se o potencial papel dos componentes químicos dos óleos comestíveis como determinantes da capacidade antioxidante total, assim como a possível relação da capacidade antioxidante com a bioatividade e a estabilidade oxidativa dos óleos. Finalmente, discutem-se evidências de que, caso seja sistematicamente investigado em trabalhos experimentais futuros, o uso de ensaios de capacidade antioxidante total na análise de óleos vegetais pode contribuir para integrar o conhecimento da composição química com a bioatividade e possivelmente com a estabilidade de óleos vegetais específicos. Dessa forma, os ensaios de capacidade antioxidante apresentam potencial para aplicação no controle da qualidade integral de óleos comestíveis.The total antioxidant capacity of edible vegetable oils is determined by their physical-chemical composition and might be associated with their quality attributes, especially with bioactivity and possibly with oxidative stability. The current review presents the fundamentals of total antioxidant capacity assays and critically evaluates the assays applicable to the analysis of oils. The role of the chemical components of edible oils as determinants of total antioxidant capacity is discussed, as well as the potential associations between antioxidant capacity and bioactivity or oxidative stability of the selected oils. Finally, we discuss evidences that, if systematically addressed in future experimental work, the application of

  3. Investment, managerial capacity, and bias in public health preparedness.

    Science.gov (United States)

    Langabeer, James R; DelliFraine, Jami L; Tyson, Sandra; Emert, Jamie M; Herbold, John

    2009-01-01

    Nearly $7 billion has been invested through national cooperative funding since 2002 to strengthen state and local response capacity. Yet, very little outcome evidence exists to analyze funding effectiveness. The objective of this research is to analyze the relationship between investment (funding) and capacity (readiness) for public health preparedness (PHP). The aim of the authors is to use a management framework to evaluate capacity, and to explore the "immediacy bias" impact on investment stability. This study employs a longitudinal study design, incorporating survey research of the entire population of 68 health departments in the state of Texas. The authors assessed the investment-capacity relationship through several statistical methods. The authors created a structural measure of managerial capacity through principal components analysis, factorizing 10 independent variables and augment this with a perceived readiness level reported from PHP managers. The authors then employ analysis of variance, correlation analyses, and other descriptive statistics. There has been a 539 percent coefficient of variation in funding at the local level between the years 2004 and 2008, and a 63 percent reduction in total resources since the peak of funding, using paired sample data. Results suggest that investment is positively associated with readiness and managerial capacity in local health departments. The authors also find that investment was related to greater community collaboration, higher adoption of Incident Command System (ICS) structure, and more frequent operational drills and exercises. Greater investment is associated with higher levels of capacity and readiness. The authors conclude from this that investment should be stabilized and continued, and not be influenced by historical cognitive biases.

  4. The relationship of aerobic capacity, anaerobic peak power and experience to performance in in CrossFit exercise

    Directory of Open Access Journals (Sweden)

    D Bellar

    2015-11-01

    Full Text Available CrossFit is becoming increasingly popular as a method to increase fitness and as a competitive sport in both the Unites States and Europe. However, little research on this mode of exercise has been performed to date. The purpose of the present investigation involving experienced CrossFit athletes and naïve healthy young men was to investigate the relationship of aerobic capacity and anaerobic power to performance in two representative CrossFit workouts: the first workout was 12 minutes in duration, and the second was based on the total time to complete the prescribed exercise. The participants were 32 healthy adult males, who were either naïve to CrossFit exercise or had competed in CrossFit competitions. Linear regression was undertaken to predict performance on the first workout (time with age, group (naïve or CrossFit athlete, VO 2 max and anaerobic power, which were all significant predictors (p<0.05 in the model. The second workout (repetitions, when examined similarly using regression, only resulted in CrossFit experience as a significant predictor (p<0.05. The results of the study suggest that a history of participation in CrossFit competition is a key component of performance in CrossFit workouts which are representative of those performed in CrossFit, and that, in at least one these workouts, aerobic capacity and anaerobic power are associated with success.

  5. Views on peak oil and its relation to climate change policy

    International Nuclear Information System (INIS)

    Verbruggen, Aviel; Al Marchohi, Mohamed

    2010-01-01

    Definitions of fossil fuel reserves and resources and assessed stock data are reviewed and clarified. Semantics explain a large stake of conflict between advocate and critical voices on peak oil. From a holistic sources-sinks perspective, limited carrying capacity of atmospheric sinks, not absolute scarcity in oil resources, will impose tight constraints on oil use. Eventually observed peaks in oil production in nearby years will result from politically imposed limits on carbon emissions, and not be caused by physical lack of oil resources. Peak-oil belief induces passive climate policy attitudes when suggesting carbon dioxide emissions will peak naturally linked to dwindling oil supplies. Active policies for reducing emissions and use of fossil fuels will also encompass higher energy end-use prices. Revenues obtained from higher levies on oil use can support financing energy efficiency and renewable energy options. But when oil producers charge the higher prices they can pump new oil for many decades, postponing peak oil to occur while extending carbon lock-in.

  6. Bayesian modeling of the assimilative capacity component of nutrient total maximum daily loads

    Science.gov (United States)

    Faulkner, B. R.

    2008-08-01

    Implementing stream restoration techniques and best management practices to reduce nonpoint source nutrients implies enhancement of the assimilative capacity for the stream system. In this paper, a Bayesian method for evaluating this component of a total maximum daily load (TMDL) load capacity is developed and applied. The joint distribution of nutrient retention metrics from a literature review of 495 measurements was used for Monte Carlo sampling with a process transfer function for nutrient attenuation. Using the resulting histograms of nutrient retention, reference prior distributions were developed for sites in which some of the metrics contributing to the transfer function were measured. Contributing metrics for the prior include stream discharge, cross-sectional area, fraction of storage volume to free stream volume, denitrification rate constant, storage zone mass transfer rate, dispersion coefficient, and others. Confidence of compliance (CC) that any given level of nutrient retention has been achieved is also determined using this approach. The shape of the CC curve is dependent on the metrics measured and serves in part as a measure of the information provided by the metrics to predict nutrient retention. It is also a direct measurement, with a margin of safety, of the fraction of export load that can be reduced through changing retention metrics. For an impaired stream in western Oklahoma, a combination of prior information and measurement of nutrient attenuation was used to illustrate the proposed approach. This method may be considered for TMDL implementation.

  7. Forecasting Strategies for Predicting Peak Electric Load Days

    Science.gov (United States)

    Saxena, Harshit

    Academic institutions spend thousands of dollars every month on their electric power consumption. Some of these institutions follow a demand charges pricing structure; here the amount a customer pays to the utility is decided based on the total energy consumed during the month, with an additional charge based on the highest average power load required by the customer over a moving window of time as decided by the utility. Therefore, it is crucial for these institutions to minimize the time periods where a high amount of electric load is demanded over a short duration of time. In order to reduce the peak loads and have more uniform energy consumption, it is imperative to predict when these peaks occur, so that appropriate mitigation strategies can be developed. The research work presented in this thesis has been conducted for Rochester Institute of Technology (RIT), where the demand charges are decided based on a 15 minute sliding window panned over the entire month. This case study makes use of different statistical and machine learning algorithms to develop a forecasting strategy for predicting the peak electric load days of the month. The proposed strategy was tested for a whole year starting May 2015 to April 2016 during which a total of 57 peak days were observed. The model predicted a total of 74 peak days during this period, 40 of these cases were true positives, hence achieving an accuracy level of 70 percent. The results obtained with the proposed forecasting strategy are promising and demonstrate an annual savings potential worth about $80,000 for a single submeter of RIT.

  8. Enhanced vegetation growth peak and its key mechanisms

    Science.gov (United States)

    Huang, K.; Xia, J.; Wang, Y.; Ahlström, A.; Schwalm, C.; Huntzinger, D. N.; Chen, J.; Cook, R. B.; Fang, Y.; Fisher, J. B.; Jacobson, A. R.; Michalak, A.; Schaefer, K. M.; Wei, Y.; Yan, L.; Luo, Y.

    2017-12-01

    It remains unclear that whether and how the vegetation growth peak has been shifted globally during the past three decades. Here we used two global datasets of gross primary productivity (GPP) and a satellite-derived Normalized Difference Vegetation Index (NDVI) to characterize recent changes in seasonal peak vegetation growth. The attribution of changes in peak growth to their driving factors was examined with several datasets. We demonstrated that the growth peak of global vegetation has been linearly increasing during the past three decades. About 65% of this trend is evenly explained by the expanding croplands (21%), rising atmospheric [CO2] (22%), and intensifying nitrogen deposition (22%). The contribution of expanding croplands to the peak growth trend was substantiated by measurements from eddy-flux towers, sun-induced chlorophyll fluorescence and a global database of plant traits, all of which demonstrated that croplands have a higher photosynthetic capacity than other vegetation types. The contribution of rising atmospheric [CO2] and nitrogen deposition are consistent with the positive response of leaf growth to elevated [CO2] (25%) and nitrogen addition (8%) from 346 manipulated experiments. The positive effect of rising atmospheric [CO2] was also well captured by 15 terrestrial biosphere models. However, most models underestimated the contributions of land-cover change and nitrogen deposition, but overestimated the positive effect of climate change.

  9. Maximum acceptable weight of lift reflects peak lumbosacral extension moments in a functional capacity evaluation test using free style, stoop and squat lifting.

    Science.gov (United States)

    Kuijer, P P F M; van Oostrom, S H; Duijzer, K; van Dieën, J H

    2012-01-01

    It is unclear whether the maximum acceptable weight of lift (MAWL), a common psychophysical method, reflects joint kinetics when different lifting techniques are employed. In a within-participants study (n = 12), participants performed three lifting techniques--free style, stoop and squat lifting from knee to waist level--using the same dynamic functional capacity evaluation lifting test to assess MAWL and to calculate low back and knee kinetics. We assessed which knee and back kinetic parameters increased with the load mass lifted, and whether the magnitudes of the kinetic parameters were consistent across techniques when lifting MAWL. MAWL was significantly different between techniques (p = 0.03). The peak lumbosacral extension moment met both criteria: it had the highest association with the load masses lifted (r > 0.9) and was most consistent between the three techniques when lifting MAWL (ICC = 0.87). In conclusion, MAWL reflects the lumbosacral extension moment across free style, stoop and squat lifting in healthy young males, but the relation between the load mass lifted and lumbosacral extension moment is different between techniques. Tests of maximum acceptable weight of lift (MAWL) from knee to waist height are used to assess work capacity of individuals with low-back disorders. This article shows that the MAWL reflects the lumbosacral extension moment across free style, stoop and squat lifting in healthy young males, but the relation between the load mass lifted and lumbosacral extension moment is different between techniques. This suggests that standardisation of lifting technique used in tests of the MAWL would be indicated if the aim is to assess the capacity of the low back.

  10. Determination of the antioxidant capacity, total phenolic and flavonoid contents of seeds from three commercial varieties of culinary dates

    Directory of Open Access Journals (Sweden)

    Jacopo Mistrello

    2014-04-01

    Full Text Available Date seeds are a major waste product of the date industry that could offer potentially valuable material for the production of useful food ingredients. The aim of the present study was to investigate the seeds of three date varieties of the UK market (Deglet Nour, Khouat Allig, and Zahidi for their proximate composition, total phenolic (TPC, total flavonoid (TFC contents and total antioxidant capacity (TAC with a view to their eventual industrial application. Carbohydrates were present in the highest concentrations varying between 74.13 and 76.54 g 100 g-1 of date seed powder (DSP on dry weight (DW basis, followed in descending order by fats (7.64-8.84 g 100 g-1 and proteins (4.35-5.51 g 100 g-1. Potassium was found in high amounts with values ranging between 280.55 and 293.13 mg 100 g-1. The majority of the total phenolic content (2058-2984 mg GAE 100 g-1 was assumed to be composed of flavonoids (1271-1932 mg CAE 100 g-1. These families of dietary phenolics may be the major ones responsible for the high antioxidant capacity reported in date seeds, which varied from 12540 and 27699 µmol TE 100 g-1. These results suggest that date seeds can be considered a potential raw material for natural, active ingredients for food applications as well as an unexplored source of novel nutraceuticals and dietary supplements.

  11. Development of the modified sum-peak method and its application

    International Nuclear Information System (INIS)

    Ogata, Y.; Miyahara, H.; Ishihara, M.; Ishigure, N.; Yamamoto, S.; Kojima, S.

    2016-01-01

    As the sum-peak method requires the total count rate as well as the peak count rates and the sum peak count rate, this meets difficulties when a sample contains other radionuclides than the one to be measured. To solve the problem, a new method using solely the peak and the sum peak count rates was developed. The method was theoretically and experimentally confirmed using "6"0Co, "2"2Na and "1"3"4Cs. We demonstrate that the modified sum-peak method is quite simple and practical and is useful to measure multiple nuclides. - Highlights: • A modified sum-peak method for simple radioactivity measurement was developed. • The method solely requires the peak count rates and the sum peak count rate. • The method is applicable to multiple radionuclides.

  12. The Antioxidant Capacities and Total Phenolic Contents of Some Medicinal Plants in Iran

    Directory of Open Access Journals (Sweden)

    Ali Mirzaei

    2011-12-01

    Full Text Available Background & Objectives: Free radicals are highly reactive molecules may cause great damage to cell membranes and DNA and Result in inducing oxidation DNA mutations leading to cancer, degenerative, and other diseases. Plant antioxidant derived may be preventive of free radical damages. Methods & Materials: The Stems and flower sample of plants air-dried, finely ground and were extracted by ethanol: water (70:30 for 48 h. Extracts were filtered and dried under vacuum. The antioxidant activity of five ethanolic extract of medicinal plants (Descurainia Sophia, Plantago major, Trachyspermum copticum L, Coriandrum sativum and Trigonella foenum-graecum from Iran were analysed by five different methods [1,1-diphenyl-2-picrylhydrazyl (DPPH radical, 2,2,azinobis-3-ethylbenzthiazoline-6-sulphonic acid (ABTS radical cation, Ferric-reducing antioxidant power assay (FRAP, phosphomolybdenum (PMB and reducing power (RP]. In addition, for determination of antioxidant components total phenolic content was also analyzed. Results: The total phenolic content of medicinal plant ranges from 74 to 154.3 mg Gallic acid/g extract as measured by the Folin–Ciocalteau method. Values of DPPH varied from 15.5 to 19.6 µmol trolex/g. FRAP ranged from 124.2 to 753 µmol of Fe(II/g extract. Antioxidant activity of the Plantago major was always higher compared to the other plants extracts values of total phenols content and antioxidant capacity by DPPH, ABTS, FRAP, (154.33 mg GAE/g, 1856 µmol trolox, 750 µmol trolox and 1169 µmol of Fe(II/g, extract respectively. The range of total antioxidant activity by phosphomolybdenum method was 513.3 to 870 µmol trolox/g. The reducing ability of the tested extracts was between 0.31-1.26. Plantago majorwas also highest activity in both tests. Conclusion: This study clearly demonstrated that Plantago major crude extract exhibit significant antioxidant activity.

  13. Determination of in vitro total phenolic, flavonoid contents and antioxidant capacity of the methanolic extract of Echium amoenum L.

    Directory of Open Access Journals (Sweden)

    Fathi H

    2016-06-01

    Full Text Available Introduction: In traditional and modern medicine, active ingredients of medicinal plants have many applications in food, pharmaceutical, medical and industry. Antioxidants are compounds that prevent the oxidation process in the cell. Echium amoenum L. is a plant which grows in the mountainous regions of Mazandaran. This plant has different biological effects such as sedation, anti-inflammation, antidepressant and cancer preventive properties in traditional medicine. The aim of this study was to determine the total phenolic, flavonoid contents and antioxidant capacity of the methanolic extract of E.amoenum plant. Methods:In this experimental laboratory study the content of total phenolic Using the folin-siokalatio reactive at 760 nm wavelength and flavonoid With the use of aluminum chloride reagent at 420nm of E.amoenum extract were measured and antioxidant capacities of different concentrations of the extract were evaluated. Results: The results showed that total phenolic content of the extract was 429±2μg gallic acid equivalent/ml and flavonoid content was 148.56±1.52μg quercetin equivalent/ml, respectively. The radical scavenging activity by 2, 2-diphenyl-1-picryl-hydrazyl hydrate (DPPH,inhibitory concentration of 50%(IC50,was determined 178.11 μg/ml. Assessment of the reducing ability of extract showed that the extract had more activity than vitamin C. The percent nitric oxide trap inhibition of the extract was 57.89% and power iron chelating properties was 51.74%,that showed statistically significant difference in comparison with vitamin C and Quercetin (P=0.0473 and (P=0.0096 respectively. Conclusion: According to the results, E.amoenum extract had remarkable antioxidant capacity and can be proposed as an antioxidant compound used in the manufacture of food and pharmaceutical products.

  14. The spatial resolution of epidemic peaks.

    Directory of Open Access Journals (Sweden)

    Harriet L Mills

    2014-04-01

    Full Text Available The emergence of novel respiratory pathogens can challenge the capacity of key health care resources, such as intensive care units, that are constrained to serve only specific geographical populations. An ability to predict the magnitude and timing of peak incidence at the scale of a single large population would help to accurately assess the value of interventions designed to reduce that peak. However, current disease-dynamic theory does not provide a clear understanding of the relationship between: epidemic trajectories at the scale of interest (e.g. city; population mobility; and higher resolution spatial effects (e.g. transmission within small neighbourhoods. Here, we used a spatially-explicit stochastic meta-population model of arbitrary spatial resolution to determine the effect of resolution on model-derived epidemic trajectories. We simulated an influenza-like pathogen spreading across theoretical and actual population densities and varied our assumptions about mobility using Latin-Hypercube sampling. Even though, by design, cumulative attack rates were the same for all resolutions and mobilities, peak incidences were different. Clear thresholds existed for all tested populations, such that models with resolutions lower than the threshold substantially overestimated population-wide peak incidence. The effect of resolution was most important in populations which were of lower density and lower mobility. With the expectation of accurate spatial incidence datasets in the near future, our objective was to provide a framework for how to use these data correctly in a spatial meta-population model. Our results suggest that there is a fundamental spatial resolution for any pathogen-population pair. If underlying interactions between pathogens and spatially heterogeneous populations are represented at this resolution or higher, accurate predictions of peak incidence for city-scale epidemics are feasible.

  15. Functional outcome in contemporary children with total cavopulmonary connection - Health-related physical fitness, exercise capacity and health-related quality of life.

    Science.gov (United States)

    Hock, Julia; Reiner, Barbara; Neidenbach, Rhoia C; Oberhoffer, Renate; Hager, Alfred; Ewert, Peter; Müller, Jan

    2018-03-15

    Children and adolescents with an univentricular heart after total cavopulmonary connection (TCPC) have functional impairments. This study assesses health-related physical fitness (HRPF) and exercise capacity, as well as their relation to health-related quality of life (HRQoL) in patients with an univentricular heart after total-pulmonary connection (TCPC). Between July 2014 and October 2016 a total of 78 children and adolescents with TCPC (12.0±3.2years, 21 female) performed a motor test including five tasks for strength and flexibility during their routine follow-up appointment. They also underwent a symptom limited cardio-pulmonary exercise test and filled in a HRQoL questionnaire (KINDL-R). Patients' data were compared to a recent sample of healthy children (n=1650, 12.6±2.4years, 49% female). Multivariable regressions corrected for sex, age and BMI showed that TCPC patients achieved 12.4 repetitions of curl-ups (pflexibility (-4.7cm; pmotor competence and exercise capacity, early screening for HRPF and early treatment, if indicated, is recommended. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  16. Competence building capacity shortage

    International Nuclear Information System (INIS)

    Doorman, Gerard; Wangensteen, Ivar; Bakken, Bjoern

    2005-02-01

    The objective of the project 'Competence Building Capacity Shortage' has been 'to increase knowledge about central approaches aimed at solving the peaking capacity problem in restructured power systems'. With respect to reserve markets, a model was developed in the project to analyze the relations between reserve requirements and prices in the spot and reserve markets respectively. A mathematical model was also developed and implemented, which also includes the balance market, and has a good ability to predict the relations between these markets under various assumptions. With some further development, this model can be used fore realistic analyses of these markets in a Nordic context. It was also concluded that certain system requirements with respect to frequency and time deviation can be relaxed without adverse effects. However, the requirements to system bias, Frequency Activated Operating Reserves and Frequency Activated Contingency Reserves cannot be relaxed, the latter because they must cover the dimensioning fault in the system. On the other hand, Fast Contingency Reserves can be reduced by removing requirements to national balances. Costs can furthermore be reduced by increasingly adapting a Nordic as opposed to national approach. A model for stepwise power flow was developed in the project, which is especially useful to analyze slow power system dynamics. This is relevant when analysing the effects of reserve requirements. A model for the analysis of the capacity balance in Norway and Sweden was also developed. This model is useful for looking at the future balance under various assumptions regarding e.g. weather conditions, demand growth and the development of the generation system. With respect to the present situation, if there is some price flexibility on the demand side and system operators are able to use reserves from the demand side, the probability for load shedding during the peak load hour is close to zero under the weather conditions after

  17. Complex behavior of elevators in peak traffic

    Science.gov (United States)

    Nagatani, Takashi

    2003-08-01

    We study the dynamical behavior of elevators in the morning peak traffic. We present a stochastic model of the elevators to take into account the interactions between elevators through passengers. The dynamics of the elevators is expressed in terms of a coupled nonlinear map with noises. The number of passengers carried by an elevator and the time-headway between elevators exhibit the complex behavior with varying elevator trips. It is found that the behavior of elevators exhibits a deterministic chaos even if there are no noises. The chaotic motion depends on the loading parameter, the maximum capacity of an elevator, and the number of elevators. When the loading parameter is superior to the threshold, each elevator carries a full load of passengers throughout its trip. The dependence of the threshold (transition point) on the elevator capacity is clarified.

  18. Capacity subscription and its market design impact

    International Nuclear Information System (INIS)

    Doorman, Gerard; Solem, Gerd

    2005-04-01

    Capacity Subscription (CS) implies that consumers buy (subscribe to) a certain amount of capacity. Their demand is limited to this capacity when the total power system is short of capacity and the System Operator activates controllable Load Limiting Devices (LLDs). The objective is to maintain system security by avoiding involuntary load shedding. The report describes a market design with CS. As a case study, an analysis is made of the changes in the market design of the Nordic system that would be necessary to implement CS. First the present Nordic market design is described. Focus is on the various market participants, their roles within various time horizons and their interactions. So it is described how CS works, why it works and what is necessary to make it work. Subsequently the necessary changes in the Nordic market structure are described. The major changes are the installation of the LLDs, the establishment of the necessary infrastructure to control the LLDs and the rules governing their control and the establishment of a capacity market. The major rule is that the System Operator announces LLD activation when a shortage situation is expected. In the capacity market generators offer available capacity during system peak conditions, while consumers bid their need for capacity. Market participants are the same as on the spot market, while small consumers buy through retailer. Generators are obliged to offer the capacity sold on the capacity market on the spot market during LLD activation. Failure to do so results in a penalty payment. The report further discusses issues like the need for verification procedures, import and export, generation pooling, the handling of small consumers, reserves and a possible implementation path of CS. With respect to transmission constraints it is argued that market splitting can be a viable option. It is concluded that CS can be a possible solution to maintain generation adequacy, but there are some serious challenges. The

  19. Predictors of VO2Peak in children age 6- to 7-years-old

    DEFF Research Database (Denmark)

    Dencker, Magnus; Hermansen, Bianca; Bugge, Anna

    2011-01-01

    This study investigated the predictors of aerobic fitness (VO2PEAK) in young children on a population-base. Participants were 436 children (229 boys and 207 girls) aged 6.7 ± 0.4 yrs. VO2PEAK was measured during a maximal treadmill exercise test. Physical activity was assessed by accelerometers....... Total body fat and total fat free mass were estimated from skinfold measurements. Regression analyses indicated that significant predictors for VO2PEAK per kilogram body mass were total body fat, maximal heart rate, sex, and age. Physical activity explained an additional 4-7%. Further analyses showed...... the main contributing factors for absolute values of VO2PEAK were fat free mass, maximal heart rate, sex, and age. Physical activity explained an additional 3-6%....

  20. Scavenging Capacities of Some Wines and Wine Phenolic Extracts

    Directory of Open Access Journals (Sweden)

    Ioannis G. Roussis

    2005-01-01

    Full Text Available The aim of this study was to assess the ability of different wines – a sweet red, a dry red, a sweet white, and a dry white – to scavenge the stable 1,1’-diphenyl-2-picryl-hydrazyl radical (DPPH. and to determine their phenolic composition. Both red wines contained, apart from anthocyanins, also higher concentration of total phenolics, tartaric esters, and flavonols than the two white wines. All wines exhibited scavenging activity analogous to their total phenolic content. However, their phenolics differed in antiradical potency, which was visible in their EC50 values. The dry red wine, Xinomavro, had a lower EC50 value, indicating the higher antiradical potency of its phenolics. The scavenging capacities of phenolic extracts from Xinomavro red wine on hydroxyl radicals, superoxide radicals, and singlet oxygen were also assessed. Wine total extract was fractionated by extraction, and each of the three fractions was then subfractionated by column chromatography into two subfractions. Wine total extract, and its fractions and subfractions exhibited scavenging capacity on hydroxyl radicals, superoxide radicals, and singlet oxygen, indicating the activity of many wine phenolics. The most active wine extracts towards hydroxyl radicals were characterized by the high peaks of flavanols, anthocyanins and flavonols in their HPLC-DAD chromatograms. The most active extract towards superoxide radicals was rich in flavanols and anthocyanins. The characteristic phenolics of the most active wine extracts towards singlet oxygen were flavanols, flavonols and phenolic acids. The ability of all red wine phenolic extracts to scavenge singlet oxygen, along with hydroxyl and superoxide radicals, emphasizes its health functionality.

  1. OPEC future capacity expansions

    International Nuclear Information System (INIS)

    Sandrea, I.

    2005-01-01

    This conference presentation examined OPEC future capacity expansions including highlights from 2000-2004 from the supply perspective and actions by OPEC; OPEC spare capacity in 2005/2006; medium-term capacity expansion and investments; long-term scenarios, challenges and opportunities; and upstream policies in member countries. Highlights from the supply perspective included worst than expected non-OPEC supply response; non-OPEC supply affected by a number of accidents and strikes; geopolitical tensions; and higher than expected demand for OPEC crude. OPEC's actions included closer relationship with other producers and consumers; capacity expansions in 2004 and 2005/2006; and OPEC kept the market well supplied with crude in 2004. The presentation also provided data using graphical charts on OPEC net capacity additions until 2005/2006; OPEC production versus spare capacity from 2003 to 2005; OPEC production and capacity to 2010; and change in required OPEC production from 2005-2020. Medium term expansion to 2010 includes over 60 projects. Medium-term risks such as project execution, financing, costs, demand, reserves, depletion, integration of Iraq, and geopolitical tensions were also discussed. The presentation concluded that in the long term, large uncertainties remain; the peak of world supply is not imminent; and continued and enhanced cooperation is essential to market stability. tabs., figs

  2. Peak Oil, threat or energy worlds' phantasm?

    International Nuclear Information System (INIS)

    Favennec, Jean-Pierre

    2011-01-01

    The concept of Peak Oil is based on the work of King Hubbert, a petroleum geologist who worked for Shell in the USA in the 1960's. Based on the fact that discoveries in America reached a maximum in the 1930's, he announced that American production would reach a maximum in 1969, which did actually occur. Geologists members of the Association for the Study of Peak Oil have extrapolated this result to a worldwide scale and, since oil discoveries reached a peak in the 1960's, argued that production will peak in the very near future. It is clear that hydrocarbon reserves are finite and therefore exhaustible. But little is known regarding the level of ultimate (i.e. total existing) reserves. There are probably very large reserves of non conventional oil in addition to the reserves of conventional oil. An increasing number of specialists put maximum production at less than 100 Mb/d more for geopolitical than physical reasons. Attainable peak production will probably vary from year to year and will depend on how crude oil prices develop

  3. Effect of Aerobic Training on Peak Oxygen Uptake Among Seniors Aged 70 or Older: A Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Bouaziz, Walid; Kanagaratnam, Lukshe; Vogel, Thomas; Schmitt, Elise; Dramé, Moustapha; Kaltenbach, Georges; Geny, Bernard; Lang, Pierre Olivier

    2018-01-02

    Older adults undergo a progressive decline in cardiorespiratory fitness and functional capacity. This lower peak oxygen uptake (VO 2peak ) level is associated with increased risk of frailty, dependency, loss of autonomy, and mortality from all causes. Regular physical activity and particularly aerobic training (AT) have been shown to contribute to better and healthy aging. We conducted a meta-analysis to measure the exact benefit of AT on VO 2peak in seniors aged 70 years or older. A comprehensive, systematic database search for articles was performed in Embase, Medline, PubMed Central, Science Direct, Scopus, and Web of Science using key words. Two reviewers independently assessed interventional studies for potential inclusion. Ten randomized controlled trials (RCTs) were included totaling 348 seniors aged 70 years or older. Across the trials, no high risk of bias was measured and all considered open-label arms for controls. With significant heterogeneity between the RCTs (all p seniors were, respectively, 1.72 (95% CI: 0.34-3.10) and 1.47 (95% CI: 0.60-2.34). This meta-analysis confirms the AT-associated benefits on VO 2peak in healthy and unhealthy seniors.

  4. Battery Peak Power Shaving Strategy to Prolong Battery Life for Electric Buses

    NARCIS (Netherlands)

    Pham, T.H.; Rosea, B.; Wilkins, S.

    2016-01-01

    This paper presents a battery peak power shaving strategy for battery electric buses. The developed strategy restricts the battery charge/discharge power when the propulsion power demand is high to avoid high deterioration of the battery capacity during operation. Without reducing the propulsion

  5. Total antioxidant capacity, total oxidant status and oxidative stress index in the men exposed to 1.5 T static magnetic field.

    Science.gov (United States)

    Sirmatel, O; Sert, C; Sirmatel, F; Selek, S; Yokus, B

    2007-06-01

    The aim of this study was to investigate the effects of a high-strength magnetic field produced by a magnetic resonance imaging (MRI) apparatus on oxidative stress. The effects of a 1.5 T static magnetic field on the total antioxidant capacity (TAC), total oxidant status (TOS) and oxidative stress index (OSI) in male subjects were investigated. In this study, 33 male volunteers were exposed to a 1.5 T static magnetic field for a short time and the TAC, TOS and OSI of each subject were determined. Magnetic field exposure was provided using a magnetic resonance apparatus; radiofrequency was not applied. Blood samples were taken from subjects and TAC, TOS and OSI values were measured using the methods of Erel. TAC showed a significant increase in post-exposures compared to pre-exposures to the magnetic field (p < 0.05). OSI and TOS showed a significant decrease in post-exposures compared to pre-exposures to a 1.5 T magnetic field (for each of two, p < 0.01). The 1.5 T static magnetic field used in the MRI apparatus did not yield a negative effect; on the contrary, it produced the positive effect of decreasing oxidative stress in men following short-term exposure.

  6. Bran data of total flavonoid and total phenolic contents, oxygen radical absorbance capacity, and profiles of proanthocyanidins and whole grain physical traits of 32 red and purple rice varieties

    Directory of Open Access Journals (Sweden)

    Ming-Hsuan Chen

    2016-09-01

    Full Text Available Phytochemicals in red and purple bran rice have potential health benefit to humans. We determined the phytochemicals in brans of 32 red and purple global rice varieties. The description of the origin and physical traits of the whole grain (color, length, width, thickness and 100-kernel weight of this germplasm collection are provided along with data of total flavonoid and total phenolic contents, oxygen radical absorbance capacity and total proanthocyanidin contents. The contents and proportions of individual oligomers, from degree of polymerization of monomers to 14-mers, and polymers in bran of these 32 rice varieties are presented (DOI: http://dx.doi.org/10.1016/j.foodchem.2016.04.004 [1]. Keywords: Purple rice, Red rice, Black rice, Proanthocyanidins, Tannins, Flavonoids, Rice bran

  7. Free radical scavenging and total antioxidant capacity of root extracts of Anchomanes difformis Engl. (Araceae).

    Science.gov (United States)

    Aliyu, Abubakar B; Ibrahim, Mohammed A; Musa, Aliyu M; Musa, Aisha O; Kiplimo, Joyce J; Oyewale, Adebayo O

    2013-01-01

    Antioxidants activities from plants sources have attracted a wide range of interest across the world in recent times. This is due to growing concern for safe and alternative sources of antioxidants. The free radical scavenging activity using 1,1-diphenyl-2-picrylhydrazyl radical (DPPH), reducing power assay, total antioxidant capacity of the phosphomolybdenum method and the total phenolics content using the Folin-Ciocalteu reagent were carried out on the acetone, n-butanol and methanol root extracts of Anchomanes difformis. The results of the total phenolics content expressed in mg/100 g of gallic acid equivalent (GAE) showed that the n-butanol extract has significantly (p extracts. All the extracts displayed strong concentration dependent radical scavenging activity. It was also observed that the n-butanol extract showed higher activity of 70.87% and 78.59% at low concentrations of 31.25 microg/mL and 62.5 microg/mL, respectively, than methanol and acetone extracts. The results also showed that the n-butanol extract has strongest reducing ability which is comparable to that of gallic acid at all the concentrations tested. Phytochemical screening on the extracts revealed the presence of flavonoids, saponins, and tannins. The results suggest that n-butanol extract of the plant is very rich in antioxidant compounds worthy of further investigations.

  8. Security of supply, energy spillage control and peaking options within a 100% renewable electricity system for New Zealand

    International Nuclear Information System (INIS)

    Mason, I.G.; Page, S.C.; Williamson, A.G.

    2013-01-01

    In this paper, issues of security of supply, energy spillage control, and peaking options, within a fully renewable electricity system, are addressed. We show that a generation mix comprising 49% hydro, 23% wind, 13% geothermal, 14% pumped hydro energy storage peaking plant, and 1% biomass-fuelled generation on an installed capacity basis, was capable of ensuring security of supply over an historic 6-year period, which included the driest hydrological year on record in New Zealand since 1931. Hydro spillage was minimised, or eliminated, by curtailing a proportion of geothermal generation. Wind spillage was substantially reduced by utilising surplus generation for peaking purposes, resulting in up to 99.8% utilisation of wind energy. Peaking requirements were satisfied using 1550 MW of pumped hydro energy storage generation, with a capacity factor of 0.76% and an upper reservoir storage equivalent to 8% of existing hydro storage capacity. It is proposed that alternative peaking options, including biomass-fuelled gas turbines and demand-side measures, should be considered. As a transitional policy, the use of fossil-gas–fuelled gas turbines for peaking would result in a 99.8% renewable system on an energy basis. Further research into whether a market-based system is capable of delivering such a renewable electricity system is suggested. - Highlights: • A 100% renewable electricity system was modelled over a 6-year period. • Security of supply was demonstrated, including for the driest year since 1931. • Stored energy spillage was controlled by using flexible base-load generation. • Wind energy utilisation of 99.8% was obtained. • Transitional use of fossil gas for peaking resulted in a 99.8% renewable system

  9. CO 2 Capture Capacity and Swelling Measurements of Liquid-like Nanoparticle Organic Hybrid Materials via Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy

    KAUST Repository

    Park, Youngjune; Shin, Dolly; Jang, Young Nam; Park, Ah-Hyung Alissa

    2012-01-01

    attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy. Simultaneous measurements of CO 2 capture capacity and swelling behaviors of polyetheramine (Jeffamine M-2070) and its corresponding NOHMs (NOHM-I-PE2070) were reported

  10. Generation Capacity Investments and High Levels of Renewables. The Impact of a German Capacity Market on Northwest Europe. Discussion paper

    Energy Technology Data Exchange (ETDEWEB)

    Ozdemir, O.; De Joode, J.; Koutstaal, P.R.; Van Hout, M. [ECN Policy Studies, Amsterdam (Netherlands)

    2013-05-15

    Presently, Northwest European centralised electricity markets are designed as 'energy-only' markets. In an energy-only market, the price received for electricity produced is set by the marginal generation unit. Potentially, the designs of these markets could leave the owners of these units with 'missing money': i.e. money that is required to recover investment cost. Further, increasing penetration of renewables could exacerbate this problem. Of all the different options available to tackle the 'missing money' problem, capacity mechanisms have attracted most of the attention in recent policy debates in Europe. This paper contributes to ongoing policy discussions by providing a quantitative analysis of the phenomena of 'missing money' and capacity mechanisms in Northwest Europe. Our analysis shows that in the case of energy-only markets with a much higher penetration of intermittent electricity sources such as wind and solar PV, the 'missing money' problem may be aggravated, because operating hours for peak and mid-merit order capacity will be considerably reduced. Furthermore, unilateral introduction of capacity mechanisms in integrated electricity markets can have considerable impacts on cross-border electricity flows and investment decisions. Stand-alone introduction of a capacity market in Germany will likely result in higher investments in Germany at the expense of lower investments outside Germany and an increase in net exports from Germany. A possible advantage of a unilateral capacity mechanism in Germany may be a reduction in super-peak prices in the larger market area. Thus, neighbouring countries may have the possibility to free ride on the increase in flexible capacity in Germany. However, this advantage is conditional and depends on sufficient availability of interconnection capacity necessary to be able to use this reserve capacity. Otherwise, security of supply might be more at risk if the German

  11. Kinetic energy storage of off-peak electricity

    International Nuclear Information System (INIS)

    Simpson, L.A.; Oldaker, I.E.; Stermscheg, J.

    1975-09-01

    The concept of using large flywheels to store off-peak electricity has been considered. The development of high strength composite materials has made possible improvements in the energy storage capacity of such devices. The problems involved in designing large flywheels and their economic advantages over alternative means of energy storage are discussed. The economic arguments are based on the present or near future capabilities and costs of structural composite materials. The flywheel costs turn out to be considerably higher than for many alternative schemes including advanced batteries, gas turbine generators and pumped storage schemes. (author)

  12. Analysis of output power and capacity reduction in electrical storage facilities by peak shift control of PV system with bifacial modules

    International Nuclear Information System (INIS)

    Obara, Shin’ya; Konno, Daisuke; Utsugi, Yuta; Morel, Jorge

    2014-01-01

    Highlights: • Characteristics of a large-scale power plant using bifacial solar cell is described. • Conversion efficiency of bifacial photovoltaics obtained using 3D-CAD modeling. • Power supply of bifacial PV can be matched with demand by adjusting the orientation. - Abstract: Bifacial photovoltaics are widely investigated with the aim of reducing the amount of silicon used and increasing conversion efficiencies. The output power of bifacial photovoltaics depends on the quantity of solar radiation incident on the reverse face. Furthermore, controlling the orientation can distribute the times of peak power output in the morning and afternoon to better match the demand. In this study, the demand patterns of individual houses or the whole Hokkaido region were analyzed assuming the substitution of a conventional large-scale electric power system with one using bifacial photovoltaics. The supply–demand balances and electrical storage capacities were investigated. When comparing a large scale solar power plant (mega-solar power plant) using monofacial photovoltaics or vertical bifacial photovoltaics (in which the orientation could be adjusted), the supply–demand could be better balanced for individual houses in the latter case, thereby allowing the storage capacity to be reduced. A bifacial solar module was modeled by 3D-CAD (three dimensional computer aided design) and thermal fluid analysis. The module temperature distribution of bifacial photovoltaics was calculated with respect to the environmental conditions (wind flow, direct and diffuse solar radiation, etc.) and internal heat generation, as well as the orientation of the solar panels. Furthermore, the output power of bifacial photovoltaics can be easily obtained from the analysis result of modular temperature distribution and the relation between temperature and output power

  13. Changes in Peak Oxygen Uptake and Plasma Volume in Fit and Unfit Subjects Following Exposure to a Simulation of Microgravity

    National Research Council Canada - National Science Library

    Convertino, Victor

    1997-01-01

    To test the hypothesis that the magnitude of reduction in plasma volume and work capacity following exposure to simulated microgravity is dependent on the initial level of aerobic fitness, peak oxygen uptake (VO2peak...

  14. Installed capacity in New York

    International Nuclear Information System (INIS)

    Charlton, J.

    2006-01-01

    This presentation discussed capacity issues related to the New York Independent System Operator (NYISO). The NYISO's market volume was approximately $11 billion in 2005, and it was responsible for providing 32,075 MW of electricity at peak load to its users. Regulatory uncertainty is currently discouraging investment in new generating resources. All load serving entities are required to contract for sufficient capacity in order to meet their capacity obligations. Market participants currently determine capacity and energy revenues. The NYISO market allows suppliers to recover variable costs for providing ancillary services, and the economic value of the revenue source governs decisions made in the wholesale electricity market. The installed capacity market was designed as a spot auction deficiency auction. Phased-in demand curves are used to modify the installed capacity market's design. A sloped demand curve mechanism is used to value capacity above the minimum requirement for both reliability and competition. Participation in the day-ahead market enhances competition and exerts downward pressure on energy and ancillary service market prices. It was concluded that the market structures and design features of the installed capacity markets recognize the need for system reliability in addition to encouraging robust competition and recognizing energy price caps and regulatory oversights. tabs., figs

  15. Effect of pH buffering capacity and sources of dietary sulfur on rumen fermentation, sulfide production, methane production, sulfate reducing bacteria, and total Archaea in in vitro rumen cultures.

    Science.gov (United States)

    Wu, Hao; Meng, Qingxiang; Yu, Zhongtang

    2015-06-01

    The effects of three types of dietary sulfur on in vitro fermentation characteristics, sulfide production, methane production, and microbial populations at two different buffer capacities were examined using in vitro rumen cultures. Addition of dry distilled grain with soluble (DDGS) generally decreased total gas production, degradation of dry matter and neutral detergent fiber, and concentration of total volatile fatty acids, while increasing ammonia concentration. High buffering capacity alleviated these adverse effects on fermentation. Increased sulfur content resulted in decreased methane emission, but total Archaea population was not changed significantly. The population of sulfate reducing bacteria was increased in a sulfur type-dependent manner. These results suggest that types of dietary sulfur and buffering capacity can affect rumen fermentation and sulfide production. Diet buffering capacity, and probably alkalinity, may be increased to alleviate some of the adverse effects associated with feeding DDGS at high levels. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. ANAEROBIC CAPACITY MAY NOT BE DETERMINED BY CRITICAL POWER MODEL IN ELITE TABLE TENNIS PLAYERS

    Directory of Open Access Journals (Sweden)

    Alessandro M. Zagatto

    2008-03-01

    Full Text Available The aim of the present study was to verify the applicability of anaerobic work capacity (AWC determined from the critical power model in elite table tennis players. Eight male international level table tennis players participated in the study. The tests undertaken were: 1 A critical frequency test used to determinate the anaerobic work capacity; 2 Wingate tests were performed using leg and arm ergometers. AWC corresponded to 99.5 ± 29.1 table tennis balls. AWC was not related to peak (r = -0.25, mean (r = -0.02, relative peak (r = -0.49 or relative mean power (r = 0.01, nor fatigue index (r = -0.52 (Wingate leg ergometer. Similar correlations for peak (r = -0.34, mean (r = -0.04, relative peak (r = -0.49, relative mean power (r = -0.14 and peak blood lactate concentration (r = -0.08 were determined in the Wingate arm ergometer test. Based on these results the AWC determined by a modified critical power test was not a good index for measurement of anaerobic capacity in table tennis players

  17. A Comparison of Total Antioxidant Capacities of Concord, Purple, Red, and Green Grapes Using the CUPRAC Assay

    Directory of Open Access Journals (Sweden)

    Connor M. Callaghan

    2013-10-01

    Full Text Available Considering how popular grapes are in terms of their antioxidant benefits, we compared concord, purple, red, and green grapes for total antioxidant capacity (TAC and carbohydrate concentration. All grapes were acquired from commercial sources and samples of each were separated into skinned and not skinned groups. Each whole grape and the skins were individually homogenized and then separated into pulp and supernatant fractions. Each fraction was analyzed for total TAC and carbohydrates. The concord grapes and purple grapes had significantly higher TAC in the homogenates than did the red or green grapes. The concord grapes and green grapes had significantly higher TAC in the pulp than in the cytosol whereas the red and purple grapes had approximately the same amount. The majority of the TAC of the purple and red grapes was in the skin whereas the concord and green grapes had approximately the same TAC in the skin and pulp. The concord and purple grapes had the highest TAC when compared to the red and green grapes, whereas the red and green grapes had approximately the same total TAC.

  18. Peak experiences of psilocybin users and non-users.

    Science.gov (United States)

    Cummins, Christina; Lyke, Jennifer

    2013-01-01

    Maslow (1970) defined peak experiences as the most wonderful experiences of a person's life, which may include a sense of awe, well-being, or transcendence. Furthermore, recent research has suggested that psilocybin can produce experiences subjectively rated as uniquely meaningful and significant (Griffiths et al. 2006). It is therefore possible that psilocybin may facilitate or change the nature of peak experiences in users compared to non-users. This study was designed to compare the peak experiences of psilocybin users and non-users, to evaluate the frequency of peak experiences while under the influence of psilocybin, and to assess the perceived degree of alteration of consciousness during these experiences. Participants were recruited through convenience and snowball sampling from undergraduate classes and at a musical event. Participants were divided into three groups, those who reported a peak experience while under the influence of psilocybin (psilocybin peak experience: PPE), participants who had used psilocybin but reported their peak experiences did not occur while they were under the influence of psilocybin (non-psilocybin peak experience: NPPE), and participants who had never used psilocybin (non-user: NU). A total of 101 participants were asked to think about their peak experiences and complete a measure evaluating the degree of alteration of consciousness during that experience. Results indicated that 47% of psilocybin users reported their peak experience occurred while using psilocybin. In addition, there were significant differences among the three groups on all dimensions of alteration of consciousness. Future research is necessary to identify factors that influence the peak experiences of psilocybin users in naturalistic settings and contribute to the different characteristics of peak experiences of psilocybin users and non-users.

  19. Suspended particle and pathogen peak discharge buffering by a surface-flow constructed wetland

    NARCIS (Netherlands)

    Mulling, B.T.M.; van den Boomen, R.M.; van der Geest, H.G.; Kappelhof, J.W.N.M.; Admiraal, W.

    2013-01-01

    Constructed wetlands (CWs) have been shown to improve the water quality of treated wastewater. The capacity of CWs to reduce nutrients, pathogens and organic matter and restore oxygen regime under normal operating conditions cannot be extrapolated to periods of incidental peak discharges. The

  20. Acute effect of sorghum flour-containing pasta on plasma total polyphenols, antioxidant capacity and oxidative stress markers in healthy subjects: A randomised controlled trial.

    Science.gov (United States)

    Khan, Imran; Yousif, Adel M; Johnson, Stuart K; Gamlath, Shirani

    2015-06-01

    It has been previously reported that pasta containing wholegrain sorghum flour exhibits high content of polyphenols and antioxidant capacity and hence might enhance antioxidant status and reduce markers of oxidative stress in vivo; however no clinical studies have yet been reported. Therefore, the present study assessed the effect of pasta containing red or white wholegrain sorghum flour on plasma total polyphenols, antioxidant capacity and oxidative stress markers in humans. The study was registered with the Australian New Zealand Clinical Trials Registry (ACTRN: 12612000324819). In a randomised crossover design, healthy subjects (n = 20) consumed three test meals of control pasta (CP), 30% red sorghum pasta (RSP) or 30% white sorghum pasta (WSP), 1-2 wk apart. The test meals were consumed as breakfast after an overnight fast. Blood samples were obtained at fasting and 2 h after consumption and analysed for total polyphenols, antioxidant capacity, superoxide dismutase (SOD) activity, protein carbonyl and 8-isoprostanes. Compared to baseline, the 2 h post-prandial levels following the RSP meal of plasma polyphenols, antioxidant capacity and SOD activity were significantly (P pasta containing red wholegrain sorghum flour enhanced antioxidant status and improved markers of oxidative stress in healthy subjects. Copyright © 2014 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  1. Improving aerobic capacity through active videogames: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Jorge Luiz de Brito-Gomes

    2015-09-01

    Full Text Available AbstractThe rate of peak workload improvement between different types of Active Video Games (AVG in young sedentary adults was investigated. Aerobic capacity improvement after a 6-week intervention between AVG types was also compared. Twenty participants, after baseline assessments, were randomized into one of three parallel groups: structured AVG (n= 6, unstructured AVG (n= 7 and a control group (n= 7. Participants played their respective AVG 3 times a week for 6-weeks (30 minutes-session. The control group maintained normal activities. Both structured and unstructured AVG improved peak workload after four weeks but only the structured group maintained this improvement through week five and six. Aerobic capacity improved in the unstructured (Pre: 36.0 ± 5.2ml.kg.min-¹,Post: 39.7 ± 4.9ml.kg.min-¹, p = .038 and structured AVG (Pre: 39.0 ± 5.9ml.kg.min-¹,Post: 47.8 ± 4.3ml.kg.min-¹, p = .006 groups. Structured AVG provide greater health benefits to aerobic capacity and peak workload in young sedentary but otherwise healthy males relative to unstructured AVG.

  2. [A peak recognition algorithm designed for chromatographic peaks of transformer oil].

    Science.gov (United States)

    Ou, Linjun; Cao, Jian

    2014-09-01

    In the field of the chromatographic peak identification of the transformer oil, the traditional first-order derivative requires slope threshold to achieve peak identification. In terms of its shortcomings of low automation and easy distortion, the first-order derivative method was improved by applying the moving average iterative method and the normalized analysis techniques to identify the peaks. Accurate identification of the chromatographic peaks was realized through using multiple iterations of the moving average of signal curves and square wave curves to determine the optimal value of the normalized peak identification parameters, combined with the absolute peak retention times and peak window. The experimental results show that this algorithm can accurately identify the peaks and is not sensitive to the noise, the chromatographic peak width or the peak shape changes. It has strong adaptability to meet the on-site requirements of online monitoring devices of dissolved gases in transformer oil.

  3. Fundamental Limits of Parallel Optical Wireless Channels: Capacity Results and Outage Formulation

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2016-01-01

    Multi-channel (MC) optical wireless communication (OWC) systems employing wave-division multiplexing for outdoors free-space optical communications, or multi-user timedivision multiple access for indoors visible-light communications, e.g., can be modeled as parallel channels. Multi-input multioutput OWC systems can also be transformed, possibly with some performance loss, to parallel channels using pre-/postcoding. Studying the performance of such MC-OWC systems requires characterizing the capacity of the underlying parallel channels. In this paper, upper and lower bounds on the capacity of constant parallel OWC channels with a total average intensity constraint are derived. Then, the paper focuses on finding intensity allocations that maximize the lower bounds given channel-state information at the transmitter (CSIT). Due to its nonconvexity, the KKT conditions are used to describe a list of candidate allocations. Instead searching exhaustively for the best solution, low-complexity near-optimal algorithms are proposed. The resulting optimized lower bound nearly coincides with capacity at high signal-to-noise ratio (SNR). Under a quasi-static channel model and in the absence of CSIT, outage probability upper and lower bounds are derived. Those bounds also meet at high SNR, thus characterizing the outage capacity in this regime. Finally, the results are extended to a system with both average and peak intensity constraints.

  4. Fundamental Limits of Parallel Optical Wireless Channels: Capacity Results and Outage Formulation

    KAUST Repository

    Chaaban, Anas

    2016-10-26

    Multi-channel (MC) optical wireless communication (OWC) systems employing wave-division multiplexing for outdoors free-space optical communications, or multi-user timedivision multiple access for indoors visible-light communications, e.g., can be modeled as parallel channels. Multi-input multioutput OWC systems can also be transformed, possibly with some performance loss, to parallel channels using pre-/postcoding. Studying the performance of such MC-OWC systems requires characterizing the capacity of the underlying parallel channels. In this paper, upper and lower bounds on the capacity of constant parallel OWC channels with a total average intensity constraint are derived. Then, the paper focuses on finding intensity allocations that maximize the lower bounds given channel-state information at the transmitter (CSIT). Due to its nonconvexity, the KKT conditions are used to describe a list of candidate allocations. Instead searching exhaustively for the best solution, low-complexity near-optimal algorithms are proposed. The resulting optimized lower bound nearly coincides with capacity at high signal-to-noise ratio (SNR). Under a quasi-static channel model and in the absence of CSIT, outage probability upper and lower bounds are derived. Those bounds also meet at high SNR, thus characterizing the outage capacity in this regime. Finally, the results are extended to a system with both average and peak intensity constraints.

  5. Avoiding the False Peaks in Correlation Discrimination

    International Nuclear Information System (INIS)

    Awwal, A.S.

    2009-01-01

    Fiducials imprinted on laser beams are used to perform video image based alignment of the 192 laser beams in the National Ignition Facility (NIF) of Lawrence Livermore National Laboratory. In many video images, matched filtering is used to detect the location of these fiducials. Generally, the highest correlation peak is used to determine the position of the fiducials. However, when the signal to-be-detected is very weak compared to the noise, this approach totally breaks down. The highest peaks act as traps for false detection. The active target images used for automatic alignment in the National Ignition Facility are examples of such images. In these images, the fiducials of interest exhibit extremely low intensity and contrast, surrounded by high intensity reflection from metallic objects. Consequently, the highest correlation peaks are caused by these bright objects. In this work, we show how the shape of the correlation is exploited to isolate the valid matches from hundreds of invalid correlation peaks, and therefore identify extremely faint fiducials under very challenging imaging conditions

  6. A new automated method for the determination of the Total Antioxidant Capacity (TAC of human plasma, based on the crocin bleaching assay

    Directory of Open Access Journals (Sweden)

    Notas George

    2002-08-01

    Full Text Available Abstract Background Antioxidant molecules, which scavenge free radical species to prevent or delay oxidative damage of important macromolecules, membrane lipids and lipoproteins, are prevalent in plasma and other biological fluids. Among them, bilirubin, uric acid and protein thiols are the major endogenous antioxidants, while vitamins C and E, as well as a number of food-derived (polyaromatic substances, belonging to stilbens, flavonoids and phenolic acids, are the main classes of nutritional antioxidants. Assays for total antioxidant capacity in plasma differ in their type of oxidation source, target and measurement used to detect the oxidized product. Methods In the present work we present an automated assay for the estimation of blood total antioxidant capacity (TAC assay, based on the crocin bleaching (oxidation method. This method was adapted on a modern autoanalyzer, was linear over a wide range of values (0–3 mmol/L, and performed using an end point measurement. Results The TAC method presented a linear correlation with another automated commercial Total Antioxidant Status (TAS test. Detection of the interference of different metabolites revealed a significant participation of TAC from uric acid, bilirubin, albumin, a minor interference from ascorbic acid, and no interference from hemoglobin. TAC was not modified by two freeze/thawing cycles, and was stable in samples stored at room temperature for 4 hours. K-EDTA and heparin were the best anticoagulants, while citrate decreased TAC by 20%. Reference values derived from samples of normal blood donors was 1.175 ± 0.007 mmol/L (mean ± SEM, while a diet rich in antioxidants more than doubled this value. Conclusions The proposed TAC assay, is fully automated, stable and reliable, and could be of value in the estimation of the AC of plasma. It is further proposed to calculate the antioxidant capacity of plasma after a subtraction of all interference deriving from endogenous and

  7. Maintained peak leg and pulmonary VO2 despite substantial reduction in muscle mitochondrial capacity

    DEFF Research Database (Denmark)

    Boushel, Robert; Gnaiger, E.; Larsen, F. J.

    2015-01-01

    We recently reported the circulatory and muscle oxidative capacities of the arm after prolonged low-intensity skiing in the arctic (Boushel et al., 2014). In the present study, leg VO2 was measured by the Fick method during leg cycling while muscle mitochondrial capacity was examined on a biopsy ...... at a higher mitochondrial p50. These findings support the concept that muscle mitochondrial respiration is submaximal at VO2max , and that mitochondrial volume can be downregulated by chronic energy demand....

  8. Pilot study for home monitoring of cough capacity in amyotrophic lateral sclerosis: A case series.

    Science.gov (United States)

    Paneroni, M; Trainini, D; Winck, J C; Vitacca, M

    2014-01-01

    Cough capacity derangement is associated with a high risk of pulmonary complications in amyotrophic lateral sclerosis patients when cough assistance is not routinely performed at home. The primary aim of this study was to evaluate the feasibility of a long-term home based daily self-monitoring cough capacity. Eighteen subjects were enrolled in a 9-month study at home. Changes in peak cough expiratory flow, oxygen saturation, respiratory discomfort and incidence of respiratory deterioration events were evaluated. In subjects presenting respiratory deterioration events, decline in the abovementioned respiratory variables was evaluated (#NCT00613899). During an average follow-up of 125±102 days, a total of 1175 measures were performed on 12 subjects. Mean compliance to proposed evaluations was 37±32% which worsened over time. Peak cough expiratory flow decreased by 15.08±32.43L/min monthly. Five subjects reported 6 episodes of respiratory deterioration events, after a mean period of 136±108 days. They had poor respiratory function and more years of disease. There was no difference in peak cough expiratory flow and its decline whether subjects presented respiratory deterioration events or not. In 4 subjects the respiratory discomfort score significantly worsened after respiratory deterioration events from 3.0±1.41 to 4.25±1.71. Daily self-monitoring of peak cough expiratory flow, oxygen saturation and respiratory discomfort seems difficult to obtain because of poor adherence to measures; this protocol does not seem to add anything to current practice of advising on clinical derangements. Confirmatory larger studies are necessary. Copyright © 2013 Sociedade Portuguesa de Pneumologia. Published by Elsevier España. All rights reserved.

  9. Determination of the full energy peak efficiency of NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Cesana, A.; Terrani, M.

    1978-01-01

    A simple procedure for the accurate evaluation of the full energy peak efficiency of NaI(Tl) crystals is described. Particular attention is given to the peak to total ratio determination for which a new method is proposed. (author)

  10. Advancements of ultra-high peak power laser diode arrays

    Science.gov (United States)

    Crawford, D.; Thiagarajan, P.; Goings, J.; Caliva, B.; Smith, S.; Walker, R.

    2018-02-01

    Enhancements of laser diode epitaxy in conjunction with process and packaging improvements have led to the availability of 1cm bars capable of over 500W peak power at near-infrared wavelengths (770nm to 1100nm). Advances in cooler design allow for multi-bar stacks with bar-to-bar pitches as low as 350μm and a scalable package architecture enabled a single diode assembly with total peak powers of over 1MegaWatt of peak power. With the addition of micro-optics, overall array brightness greater than 10kW/cm2 was achieved. Performance metrics of barbased diode lasers specifically engineered for high peak power and high brightness at wavelengths and pulse conditions commonly used to pump a variety of fiber and solid-state materials are presented.

  11. System dynamics model of Hubbert Peak for China's oil

    International Nuclear Information System (INIS)

    Tao Zaipu; Li Mingyu

    2007-01-01

    American geophysicist M. King Hubbert in 1956 first introduced a logistic equation to estimate the peak and lifetime production for oil of USA. Since then, a fierce debate ensued on the so-called Hubbert Peak, including also its methodology. This paper proposes to use the generic STELLA model to simulate Hubbert Peak, particularly for the Chinese oil production. This model is demonstrated as being robust. We used three scenarios to estimate the Chinese oil peak: according to scenario 1 of this model, the Hubbert Peak for China's crude oil production appears to be in 2019 with a value of 199.5 million tonnes, which is about 1.1 times the 2005 output. Before the peak comes, Chinese oil output will grow by about 1-2% annually, after the peak, however, the output will fall. By 2040, the annual production of Chinese crude oil would be equivalent to the level of 1990. During the coming 20 years, the crude oil demand of China will probably grow at the rate of 2-3% annually, and the gap between domestic supply and total demand may be more than half of this demand

  12. Total peroxynitrite scavenging capacity of phenylethanoid and flavonoid glycosides from the flowers of Buddleja officinalis.

    Science.gov (United States)

    Tai, Bui Huu; Jung, Bong Yong; Cuong, Nguyen Manh; Linh, Pham Thuy; Tung, Nguyen Huu; Nhiem, Nguyen Xuan; Huong, Tran Thu; Anh, Ngo Thi; Kim, Jeong Ah; Kim, Sang Kyum; Kim, Young Ho

    2009-12-01

    Nine compounds, including six phenylethanoid glycosides: acteoside (1); bioside (2); echinacoside (3); poliumoside (4); phenylethyl glycoside (5); salidroside (6) and three flavonoids; linarin (7); apigenin (8); isorhoifolin (9), were isolated from the flowers of Buddleja officinalis MAXIM. (Buddlejaceae). Chemical structures were confirmed by (1)H-, and (13)C-NMR, and MS spectral methods and compared with those reported in the literature. Antioxidant activities of the methanol and water extracts, and all isolated compounds were evaluated using the total oxidant scavenging capacity (TOSC) assay against peroxynitrite. Results of the assay showed that the phenylethanoid glycosides, a major class of compounds of the flowers of B. officinalis, possess strong antioxidant activity. Of these, acteoside, echinacoside and poliumoside have 9.9-, 9.8- and 9.5-fold TOSC value, respectively, compared with the positive control, Trolox.

  13. Flue gas recovery system for natural gas combined heat and power plant with distributed peak-shaving heat pumps

    International Nuclear Information System (INIS)

    Zhao, Xiling; Fu, Lin; Wang, Xiaoyin; Sun, Tao; Wang, Jingyi; Zhang, Shigang

    2017-01-01

    Highlights: • A flue gas recovery system with distributed peak-shaving heat pumps is proposed. • The system can improve network transmission and distribution capacity. • The system is advantageous in energy saving, emission reduction and economic benefits. - Abstract: District heating systems use distributed heat pump peak-shaving technology to adjust heat in secondary networks of substations. This technology simultaneously adjusts the heat of the secondary network and reduces the return-water temperature of the primary network by using the heat pump principle. When optimized, low temperature return-water is able to recycle more waste heat, thereby further improving the heating efficiency of the system. This paper introduces a flue gas recovery system for a natural gas combined heat and power plant with distributed peak-shaving heat pumps. A pilot system comprising a set of two 9F gas-steam combined cycle-back pressure heating units was used to analyse the system configuration and key parameters. The proposed system improved the network transmission and distribution capacity, increased heating capacity, and reduced heating energy consumption without compromising heating safety issues. As such, the proposed system is advantageous in terms of energy saving, emission reduction, and economic benefits.

  14. Antioxidant Capacity of Beetroot: Traditional vs Novel Approaches.

    Science.gov (United States)

    Carrillo, Celia; Rey, Raquel; Hendrickx, Marc; Del Mar Cavia, María; Alonso-Torre, Sara

    2017-09-01

    Red beetroot has been ranked among the 10 most potent antioxidant vegetables, although only extraction-based methods have been used to evaluate its total antioxidant capacity. Therefore, the present study aims at comparing the traditional extraction-based method with two more recent approaches (QUENCHER -QUick, Easy, New, CHEap and Reproducible- and GAR -global antioxidant response method), in order to establish their suitability in the case of beetroot. Our results indicate that the total antioxidant capacity of beetroot would be underestimated when using extraction-based procedures, since both QUENCHER and GAR methods resulted in a higher total antioxidant capacity. The effect of a thermal treatment on the total antioxidant capacity of beetroot varies among the methods evaluated and our findings suggest different compounds responsible for the total antioxidant capacity detected in each pre-processing method. Remarkably, the present study demonstrates that the traditional extraction-based method seems useful to screen for (changes in) the "bioavailable" antioxidant potential of the root.

  15. Effect of radiation therapy on lipid peroxidation and total antioxidant capacity of blood and saliva in oral cancer patients

    International Nuclear Information System (INIS)

    Lobo, Aswin D.A.

    2012-01-01

    Radiation therapy is reported to induce oxidative stress in oral cancer patients. Saliva as a diagnostic tool has received increasing attention in recent years. Saliva analysis is proposed to be a noninvasive, sensitive tool for the evaluation of biological effects of radiation therapy in oral cancer. We aimed to assess the effect of radiation therapy on malondialdehyde, the marker of lipid peroxidation, and total antioxidant capacity in blood and saliva of oral cancer patients. We also aimed to assess the correlation between blood and saliva with respect to malonaldehyde (MDA) level and total antioxidant capacity (TAC). Thirty, clinically diagnosed oral cancer patients visiting the Oncology Department were the subjects. Thirty age- and sex-matched normal, healthy controls were included. Blood and saliva samples were collected from controls, and from oral cancer patients before and after radiation therapy. The samples were analyzed for MDA and TAC by standard spectrophotometric methods. Oral cancer patients showed significantly higher MDA level and lower TAC in blood and saliva when compared to controls. One week after radiation therapy, there was significant increase in MDA and decrease in TAC in oral cancer patients. After the completion of radiation therapy of six weeks, MDA level decreased and TAC increased, restoring the values near-to-controls. The pattern of change in MDA and TAC was similar between blood and saliva. There was significant correlation between blood and saliva with respect to MDA and TAC in oral cancer patients. Oral cancer patients showed increased oxidative stress and impaired antioxidant capacity. After radiation therapy of one week, oxidative stress increased further, and after six weeks of radiation therapy there was amelioration of antioxidant status. Saliva could be a sensitive and convenient laboratory tool for diagnosis of oral cancer and evaluation of biological effects of radiation therapy. (author)

  16. Capacity Ten-Seven

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-05-04

    The study was initiated to assemble UK solar experts who would define the parameters for the design of solar cell process plant with a capacity of about 10MWp per annum and establish the optimum substrate size, cell configuration and junction structure and show that these characteristics are suited to high volume low cost production. The study focused on proven materials and techniques rather than on innovative materials and processes. Peak production should deliver panels at a cost of less than $1 per peak watt. The study was reported under the headings of fundamental studies, front contact deposition, semiconductor deposition, rear contact deposition, cell isolation and initial design study. Since much of the work is commercially sensitive, not all findings are divulged in the report. The work, which achieved all its targets, was carried out by ICP Solar Technologies UK Ltd under contract to the DTI.

  17. L-Arginine Affects Aerobic Capacity and Muscle Metabolism in MELAS (Mitochondrial Encephalomyopathy, Lactic Acidosis and Stroke-Like Episodes Syndrome.

    Directory of Open Access Journals (Sweden)

    Lance H Rodan

    Full Text Available To study the effects of L-arginine (L-Arg on total body aerobic capacity and muscle metabolism as assessed by (31Phosphorus Magnetic Resonance Spectroscopy ((31P-MRS in patients with MELAS (Mitochondrial Encephalomyopathy with Lactic Acidosis and Stroke-like episodes syndrome.We performed a case control study in 3 MELAS siblings (m.3243A>G tRNA(leu(UUR in MTTL1 gene with different % blood mutant mtDNA to evaluate total body maximal aerobic capacity (VO(2peak using graded cycle ergometry and muscle metabolism using 31P-MRS. We then ran a clinical trial pilot study in MELAS sibs to assess response of these parameters to single dose and a 6-week steady-state trial of oral L-Arginine.At baseline (no L-Arg, MELAS had lower serum Arg (p = 0.001. On 3(1P-MRS muscle at rest, MELAS subjects had increased phosphocreatine (PCr (p = 0.05, decreased ATP (p = 0.018, and decreased intracellular Mg(2+ (p = 0.0002 when compared to matched controls. With L-arginine therapy, the following trends were noted in MELAS siblings on cycle ergometry: (1 increase in mean % maximum work at anaerobic threshold (AT (2 increase in % maximum heart rate at AT (3 small increase in VO(2peak. On (31P-MRS the following mean trends were noted: (1 A blunted decrease in pH after exercise (less acidosis (2 increase in Pi/PCr ratio (ADP suggesting increased work capacity (3 a faster half time of PCr recovery (marker of mitochondrial activity following 5 minutes of moderate intensity exercise (4 increase in torque.These results suggest an improvement in aerobic capacity and muscle metabolism in MELAS subjects in response to supplementation with L-Arg. Intramyocellular hypomagnesemia is a novel finding that warrants further study.Class III evidence that L-arginine improves aerobic capacity and muscle metabolism in MELAS subjects.ClinicalTrials.gov NCT01603446.

  18. L-Arginine Affects Aerobic Capacity and Muscle Metabolism in MELAS (Mitochondrial Encephalomyopathy, Lactic Acidosis and Stroke-Like Episodes) Syndrome.

    Science.gov (United States)

    Rodan, Lance H; Wells, Greg D; Banks, Laura; Thompson, Sara; Schneiderman, Jane E; Tein, Ingrid

    2015-01-01

    To study the effects of L-arginine (L-Arg) on total body aerobic capacity and muscle metabolism as assessed by (31)Phosphorus Magnetic Resonance Spectroscopy ((31)P-MRS) in patients with MELAS (Mitochondrial Encephalomyopathy with Lactic Acidosis and Stroke-like episodes) syndrome. We performed a case control study in 3 MELAS siblings (m.3243A>G tRNA(leu(UUR)) in MTTL1 gene) with different % blood mutant mtDNA to evaluate total body maximal aerobic capacity (VO(2peak)) using graded cycle ergometry and muscle metabolism using 31P-MRS. We then ran a clinical trial pilot study in MELAS sibs to assess response of these parameters to single dose and a 6-week steady-state trial of oral L-Arginine. At baseline (no L-Arg), MELAS had lower serum Arg (p = 0.001). On 3(1)P-MRS muscle at rest, MELAS subjects had increased phosphocreatine (PCr) (p = 0.05), decreased ATP (p = 0.018), and decreased intracellular Mg(2+) (p = 0.0002) when compared to matched controls. With L-arginine therapy, the following trends were noted in MELAS siblings on cycle ergometry: (1) increase in mean % maximum work at anaerobic threshold (AT) (2) increase in % maximum heart rate at AT (3) small increase in VO(2peak). On (31)P-MRS the following mean trends were noted: (1) A blunted decrease in pH after exercise (less acidosis) (2) increase in Pi/PCr ratio (ADP) suggesting increased work capacity (3) a faster half time of PCr recovery (marker of mitochondrial activity) following 5 minutes of moderate intensity exercise (4) increase in torque. These results suggest an improvement in aerobic capacity and muscle metabolism in MELAS subjects in response to supplementation with L-Arg. Intramyocellular hypomagnesemia is a novel finding that warrants further study. Class III evidence that L-arginine improves aerobic capacity and muscle metabolism in MELAS subjects. ClinicalTrials.gov NCT01603446.

  19. Mask effects on cosmological studies with weak-lensing peak statistics

    International Nuclear Information System (INIS)

    Liu, Xiangkun; Pan, Chuzhong; Fan, Zuhui; Wang, Qiao

    2014-01-01

    With numerical simulations, we analyze in detail how the bad data removal, i.e., the mask effect, can influence the peak statistics of the weak-lensing convergence field reconstructed from the shear measurement of background galaxies. It is found that high peak fractions are systematically enhanced because of the presence of masks; the larger the masked area is, the higher the enhancement is. In the case where the total masked area is about 13% of the survey area, the fraction of peaks with signal-to-noise ratio ν ≥ 3 is ∼11% of the total number of peaks, compared with ∼7% of the mask-free case in our considered cosmological model. This can have significant effects on cosmological studies with weak-lensing convergence peak statistics, inducing a large bias in the parameter constraints if the effects are not taken into account properly. Even for a survey area of 9 deg 2 , the bias in (Ω m , σ 8 ) is already intolerably large and close to 3σ. It is noted that most of the affected peaks are close to the masked regions. Therefore, excluding peaks in those regions in the peak statistics can reduce the bias effect but at the expense of losing usable survey areas. Further investigations find that the enhancement of the number of high peaks around the masked regions can be largely attributed to the smaller number of galaxies usable in the weak-lensing convergence reconstruction, leading to higher noise than that of the areas away from the masks. We thus develop a model in which we exclude only those very large masks with radius larger than 3' but keep all the other masked regions in peak counting statistics. For the remaining part, we treat the areas close to and away from the masked regions separately with different noise levels. It is shown that this two-noise-level model can account for the mask effect on peak statistics very well, and the bias in cosmological parameters is significantly reduced if this model is applied in the parameter fitting.

  20. Can we reconcile different capacity adequacy policies with an integrated electricity market?

    International Nuclear Information System (INIS)

    Finon, Dominique

    2013-09-01

    In the present European Union debate, many consider capacity remuneration mechanisms (CRM) as useless and, if they are eventually considered as useful, there is a necessity of total alignment of capacity adequacy policies in time. We develop an opposite position. The adoption of CRM is a necessity because the market and regulatory failures to invest in peaking units, which are amplified by the large, scale development of intermittent sources by out-of-market policies. Then, provided that some minimal harmonization is sought by regulators and TSOs, each member state should have some freedom in the adoption of his capacity adequacy policies. Our main findings are fivefold: 1 - beyond the need for a clear alignment of principles in matters of criteria of adequacy and reliability, Member States are legitimate to decide their means of action to maintain the long-term reliability insurance of their electricity system. In particular they should be allowed to choose between keeping 'energy only' market architecture or adding a capacity mechanism, and also to choose the type of CRM design, provided that they target a minimal probabilistic criteria of outages and that short term competition on the energy market is not altered. 2 - we propose the adoption of minimal criteria of adequacy and reliability in relation to the nature of hazard events which could alter the system reliability and which are specific to each system (seasonal hydraulic hazardousness, weekly thermo-sensibility of the peak load, daily and hourly variability of intermittent renewable, unplanned thermal plants outages). In a system in which the regulator and the government are totally confident in the ability of the market to reveal the level of protection desired by the consumers in a system, the absence of precautionary approach could in fact alter the supply reliability level targeted by the respective TSOs in the neighboring markets which they are integrated with. 3 - the CRMs which are quantity

  1. Determination of total antioxidant capacity of milk by CUPRAC and ABTS methods with separate characterisation of milk protein fractions.

    Science.gov (United States)

    Çekiç, Sema Demirci; Demir, Aslı; Başkan, Kevser Sözgen; Tütem, Esma; Apak, Reşat

    2015-05-01

    Most milk-applied antioxidant assays in literature are based on the isolation and quantification of individual antioxidative compounds, whereas total antioxidant capacity (TAC) gives a more holistic picture due to cooperative action of antioxidants. Recently, the cupric reducing antioxidant capacity (CUPRAC) method has been modified to measure the antioxidant capacities of thiol-containing proteins, where the classical ammonium acetate buffer - that may otherwise precipitate proteins- was replaced with concentrated urea buffer (able to expose embedded thiol groups of proteins to oxidative attack) adjusted to pH 7.0. Thus, antioxidant capacity of milk was investigated with two competing TAC assays, namely CUPRAC and ABTS (2,2'-azinobis(3-ethylbenzothiazoline-6-sulphonic acid))/persulphate, because only these assays were capable of evaluating protein contribution to the observed TAC value. As milk fat caused turbidity, experiments were carried out with skim milk or defatted milk samples. To determine TAC, modified CUPRAC method was applied to whole milk, separated and redissolved protein fractions, and the remaining liquid phase after necessary operations. Both TAC methods were investigated for their dilution sensitivity and antioxidant power assessment of separate milk fractions such as casein and whey. Proteins like β-lactoglobulin and casein (but not simple thiols) exhibited enhanced CUPRAC reactivity with surfactant (SDS) addition. Addition of milk protein fractions to whole skim milk produced significant 'negative-biased' deviations (up to -26% relative standard error) from TAC absorbance additivity in the application of the ABTS method, as opposed to that of the CUPRAC method less affected by chemical deviations from Beer's law thereby producing much smaller deviations from additivity (i.e. the property of additivity is valid when the measured TAC of a mixture is equal to the sum of individual antioxidant capacities of its constituents).

  2. Air conditioning system with supplemental ice storing and cooling capacity

    Science.gov (United States)

    Weng, Kuo-Lianq; Weng, Kuo-Liang

    1998-01-01

    The present air conditioning system with ice storing and cooling capacity can generate and store ice in its pipe assembly or in an ice storage tank particularly equipped for the system, depending on the type of the air conditioning system. The system is characterized in particular in that ice can be produced and stored in the air conditioning system whereby the time of supplying cooled air can be effectively extended with the merit that the operation cycle of the on and off of the compressor can be prolonged, extending the operation lifespan of the compressor in one aspect. In another aspect, ice production and storage in great amount can be performed in an off-peak period of the electrical power consumption and the stored ice can be utilized in the peak period of the power consumption so as to provide supplemental cooling capacity for the compressor of the air conditioning system whereby the shift of peak and off-peak power consumption can be effected with ease. The present air conditioning system can lower the installation expense for an ice-storing air conditioning system and can also be applied to an old conventional air conditioning system.

  3. Capacity investment and competition in decentralized electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    Fehr, Nils-Henrik von der; Harbord, David Cameron

    1997-11-01

    With particular reference to the recently deregulated and market-based electricity industries in Norway, the UK and elsewhere the report analyses oligopoly entry and capacity investment decisions as a non-cooperative game in a decentralized electricity market. A two-stage game is considered, with multiple capacity types and uncertain demand, in which capacity decisions are made prior to spot-market, or price competition. Equilibrium outcomes for different pricing mechanisms or regulatory regimes are analysed. The following questions are dealt with in particular: Will industry capacity be sufficient to ensure adequate supply security? Does imperfect competition in the spot-market lead to an inefficient mix of base-load and peak-load technologies? How do different regulatory policies affect the market outcomes? 24 refs., 2 figs., 1 tab.

  4. Smart households: Dispatch strategies and economic analysis of distributed energy storage for residential peak shaving

    International Nuclear Information System (INIS)

    Zheng, Menglian; Meinrenken, Christoph J.; Lackner, Klaus S.

    2015-01-01

    Highlights: • Cost-effectiveness of building-based storage for peak shaving has hitherto not been well understood. • Several existing storage technologies are shown to provide cost-effective peak shaving. • Setting grid demand targets rather than hard demand limits improves economics. • Accounting for seasonal demand variations in storage dispatch strategy improves economics further. • Total-energy-throughput approach is used to determine storage lifetimes. - Abstract: Meeting time-varying peak demand poses a key challenge to the U.S. electricity system. Building-based electricity storage – to enable demand response (DR) without curtailing actual appliance usage – offers potential benefits of lower electricity production cost, higher grid reliability, and more flexibility to integrate renewables. DR tariffs are currently available in the U.S. but building-based storage is still underutilized due to insufficiently understood cost-effectiveness and dispatch strategies. Whether DR schemes can yield a profit for building operators (i.e., reduction in electricity bill that exceeds levelized storage cost) and which particular storage technology yields the highest profit is yet to be answered. This study aims to evaluate the economics of providing peak shaving DR under a realistic tariff (Con Edison, New York), using a range of storage technologies (conventional and advanced batteries, flywheel, magnetic storage, pumped hydro, compressed air, and capacitors). An agent-based stochastic model is used to randomly generate appliance-level demand profiles for an average U.S. household. We first introduce a levelized storage cost model which is based on a total-energy-throughput lifetime. We then develop a storage dispatch strategy which optimizes the storage capacity and the demand limit on the grid. We find that (i) several storage technologies provide profitable DR; (ii) annual profit from such DR can range from 1% to 39% of the household’s non-DR electricity

  5. Fast Metabolite Identification in Nuclear Magnetic Resonance Metabolomic Studies: Statistical Peak Sorting and Peak Overlap Detection for More Reliable Database Queries.

    Science.gov (United States)

    Hoijemberg, Pablo A; Pelczer, István

    2018-01-05

    A lot of time is spent by researchers in the identification of metabolites in NMR-based metabolomic studies. The usual metabolite identification starts employing public or commercial databases to match chemical shifts thought to belong to a given compound. Statistical total correlation spectroscopy (STOCSY), in use for more than a decade, speeds the process by finding statistical correlations among peaks, being able to create a better peak list as input for the database query. However, the (normally not automated) analysis becomes challenging due to the intrinsic issue of peak overlap, where correlations of more than one compound appear in the STOCSY trace. Here we present a fully automated methodology that analyzes all STOCSY traces at once (every peak is chosen as driver peak) and overcomes the peak overlap obstacle. Peak overlap detection by clustering analysis and sorting of traces (POD-CAST) first creates an overlap matrix from the STOCSY traces, then clusters the overlap traces based on their similarity and finally calculates a cumulative overlap index (COI) to account for both strong and intermediate correlations. This information is gathered in one plot to help the user identify the groups of peaks that would belong to a single molecule and perform a more reliable database query. The simultaneous examination of all traces reduces the time of analysis, compared to viewing STOCSY traces by pairs or small groups, and condenses the redundant information in the 2D STOCSY matrix into bands containing similar traces. The COI helps in the detection of overlapping peaks, which can be added to the peak list from another cross-correlated band. POD-CAST overcomes the generally overlooked and underestimated presence of overlapping peaks and it detects them to include them in the search of all compounds contributing to the peak overlap, enabling the user to accelerate the metabolite identification process with more successful database queries and searching all tentative

  6. Content of Total Phenolics, Flavan-3-Ols and Proanthocyanidins, Oxidative Stability and Antioxidant Capacity of Chocolate During Storage

    Science.gov (United States)

    Komes, Draženka; Gorjanović, Stanislava; Belščak-Cvitanović, Ana; Pezo, Lato; Pastor, Ferenc; Ostojić, Sanja; Popov-Raljić, Jovanka; Sužnjević, Desanka

    2016-01-01

    Summary Antioxidant (AO) capacity of chocolates with 27, 44 and 75% cocoa was assessed after production and during twelve months of storage by direct current (DC) polarographic assay, based on the decrease of anodic current caused by the formation of hydroxo-perhydroxyl mercury(II) complex (HPMC) in alkaline solutions of hydrogen peroxide at potentials of mercury oxidation, and two spectrophotometric assays. Relative antioxidant capacity index (RACI) was calculated by taking the average value of the AO assay (the sample mass in all assays was identical). Oxidative stability of chocolate fat was determined by differential scanning calorimetry. Measured parameters and RACI were correlated mutually and with the content of total phenols (Folin-Ciocalteu assay), flavan-3-ols (vanillin and p-dimethylaminocinnamaldehyde assay) and proanthocyanidins (modified Bate-Smith assay). During storage, the studied functional and health-related characteristics remained unchanged. Amongst applied AO assays, the DC polarographic one, whose validity was confirmed by two-way ANOVA and F-test, correlated most significantly with oxidative stability (oxidation onset temperature and induction time). In addition, principal component analysis was applied to characterise chocolate types. PMID:27904388

  7. Content of Total Phenolics, Flavan-3-Ols and Proanthocyanidins, Oxidative Stability and Antioxidant Capacity of Chocolate During Storage

    Directory of Open Access Journals (Sweden)

    Draženka Komes

    2016-01-01

    Full Text Available Antioxidant (AO capacity of chocolates with 27, 44 and 75 % cocoa was assessed after production and during twelve months of storage by direct current (DC polarographic assay, based on the decrease of anodic current caused by the formation of hydroxo-perhydroxyl mercury(II complex (HPMC in alkaline solutions of hydrogen peroxide at potentials of mercury oxidation, and two spectrophotometric assays. Relative antioxidant capacity index (RACI was calculated by taking the average value of the AO assay (the sample mass in all assays was identical. Oxidative stability of chocolate fat was determined by differential scanning calorimetry. Measured parameters and RACI were correlated mutually and with the content of total phenols (Folin-Ciocalteu assay, flavan-3-ols (vanillin and p-dimethylaminocinnamaldehyde assay and proanthocyanidins (modified Bate-Smith assay. During storage, the studied functional and health-related characteristics remained unchanged. Amongst applied AO assays, the DC polarographic one, whose validity was confirmed by two-way ANOVA and F-test, correlated most significantly with oxidative stability (oxidation onset temperature and induction time. In addition, principal component analysis was applied to characterise chocolate types.

  8. Clinical Utility of Additional Measurement of Total Lung Capacity in Diagnosing Obstructive Lung Disease in Subjects With Restrictive Pattern of Spirometry.

    Science.gov (United States)

    Lee, Hyun; Chang, Boksoon; Kim, Kyunga; Song, Won Jun; Chon, Hae Ri; Kang, Hyung Koo; Kim, Jung Soo; Jeong, Byeong-Ho; Oh, Yeon-Mok; Koh, Won-Jung; Park, Hye Yun

    2016-04-01

    Total lung capacity (TLC), forced expiratory flow between 25 and 75% (FEF25-75%), peak expiratory flow (PEF), or post-bronchodilator volume response is recommended to detect obstructive abnormalities in the lung. The present study was performed to evaluate the usefulness of these pulmonary function test (PFT) parameters to diagnose obstructive lung disease in subjects with a restrictive pattern of spirometry. A retrospective study was conducted in 64 subjects with a restrictive pattern of spirometry (normal FEV1/FVC and low FVC) out of 3,030 patients who underwent all pre- and post-bronchodilator spirometry and lung volume measurement between April 2008 and December 2010. After subjects were clinically classified into those with obstructive lung disease, restrictive lung disease, and mixed lung disease, the agreements between the clinical diagnosis and PFT classification according to TLC, FEF(25-75%), PEF, and post-bronchodilator response criteria were compared. Of 64 subjects, 18 (28.1%) were classified with obstructive lung disease, 39 (60.9%) had restrictive lung disease, 1 (1.6%) had mixed lung disease, and 6 (9.4%) had no clinical lung disease. Among the 58 subjects with clinical lung disease, 22 (37.9%), 37 (63.8%), 33 (56.9%), and 3 (5.2%) were classified as having obstructive pattern based on TLC, FEF25-75%, PEF, and post-bronchodilator response criteria, respectively. The kappa coefficients for the agreement between the clinical classification and PFT classification using TLC, FEF25-75%, PEF, and post-bronchodilator response criteria in 58 subjects were 0.59, 0.18, 0.17, and spirometry, when obstructive lung disease is clinically suspected. Copyright © 2016 by Daedalus Enterprises.

  9. Cardiorespiratory Fitness and Peak Torque Differences between Vegetarian and Omnivore Endurance Athletes: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Heidi M. Lynch

    2016-11-01

    Full Text Available In spite of well-documented health benefits of vegetarian diets, less is known regarding the effects of these diets on athletic performance. In this cross-sectional study, we compared elite vegetarian and omnivore adult endurance athletes for maximal oxygen uptake (VO2 max and strength. Twenty-seven vegetarian (VEG and 43 omnivore (OMN athletes were evaluated using VO2 max testing on the treadmill, and strength assessment using a dynamometer to determine peak torque for leg extensions. Dietary data were assessed using detailed seven-day food logs. Although total protein intake was lower among vegetarians in comparison to omnivores, protein intake as a function of body mass did not differ by group (1.2 ± 0.3 and 1.4 ± 0.5 g/kg body mass for VEG and OMN respectively, p = 0.220. VO2 max differed for females by diet group (53.0 ± 6.9 and 47.1 ± 8.6 mL/kg/min for VEG and OMN respectively, p < 0.05 but not for males (62.6 ± 15.4 and 55.7 ± 8.4 mL/kg/min respectively. Peak torque did not differ significantly between diet groups. Results from this study indicate that vegetarian endurance athletes’ cardiorespiratory fitness was greater than that for their omnivorous counterparts, but that peak torque did not differ between diet groups. These data suggest that vegetarian diets do not compromise performance outcomes and may facilitate aerobic capacity in athletes.

  10. The creation in the French power system of a capacity mechanism and of a capacity market

    International Nuclear Information System (INIS)

    Meda, Maurice

    2014-01-01

    The key objective of the French capacity remuneration mechanism is to ensure long term security of supply and to promote peak load containment. The mechanism was set up by the NOME law of December 7, 2010 ('new organisation of the electricity market'), which has changed the organisation of the electricity market and explicitly requires a capacity obligation from suppliers, and by a decree published on December 14, 2012 'concerning the contribution of suppliers to the security of electricity supply and establishing a capacity obligation mechanism in the electricity sector'; further regulation will set up the rules for the capacity mechanism, probably during 2014. The mechanism is decentralized: every supplier has to contribute to supply security and to prove its ability to provide its clients with the capacity they need; all capacity owners in metropolitan France must have their production tools certified. Certificates can be sold and suppliers can buy them to adjust their positions. The transport System operator (TSO) calculates suppliers' obligation, checks if capacity owners fulfil their availability commitment and if suppliers have bought enough certificates. The contribution of interconnections to France's SOS is taken into account implicitly. The decree provides an additional safeguard mechanism, which is centralized: in case a critical situation is observed regarding the electricity supply and demand, the government can organize a call for tender to secure the necessary capacities; the conditions to trigger the call for tender are very restrictive, to ensure the capacity market remains the main investment provider. (author)

  11. Free-Space Optical Communications: Capacity Bounds, Approximations, and a New Sphere-Packing Perspective

    KAUST Repository

    Chaaban, Anas

    2016-02-03

    The capacity of the free-space optical channel is studied. A new recursive approach for bounding the capacity of the channel based on sphere-packing is proposed. This approach leads to new capacity upper bounds for a channel with a peak intensity constraint or an average intensity constraint. Under an average constraint only, the derived bound is tighter than an existing sphere-packing bound derived earlier by Farid and Hranilovic. The achievable rate of a truncated-Gaussian input distribution is also derived. It is shown that under both average and peak constraints, this achievable rate and the sphere-packing bounds are within a small gap at high SNR, leading to a simple high-SNR capacity approximation. Simple fitting functions that capture the best known achievable rate for the channel are provided. These functions can be of practical importance especially for the study of systems operating under atmospheric turbulence and misalignment conditions.

  12. Free-Space Optical Communications: Capacity Bounds, Approximations, and a New Sphere-Packing Perspective

    KAUST Repository

    Chaaban, Anas; Morvan, Jean-Marie; Alouini, Mohamed-Slim

    2016-01-01

    The capacity of the free-space optical channel is studied. A new recursive approach for bounding the capacity of the channel based on sphere-packing is proposed. This approach leads to new capacity upper bounds for a channel with a peak intensity constraint or an average intensity constraint. Under an average constraint only, the derived bound is tighter than an existing sphere-packing bound derived earlier by Farid and Hranilovic. The achievable rate of a truncated-Gaussian input distribution is also derived. It is shown that under both average and peak constraints, this achievable rate and the sphere-packing bounds are within a small gap at high SNR, leading to a simple high-SNR capacity approximation. Simple fitting functions that capture the best known achievable rate for the channel are provided. These functions can be of practical importance especially for the study of systems operating under atmospheric turbulence and misalignment conditions.

  13. Specific gas turbines for extreme peak-load

    International Nuclear Information System (INIS)

    Bellot, C.

    1992-12-01

    As with other European countries, in France peak consumption of electricity occurs during winter. Due to the increasing use of electricity for domestic heating, outside temperature greatly influences consumption (1 200 MW for a drop of 1 deg C). To meet requirements during cold spells, EDF has sought to determine which special facilities are best suited for extreme peak load conditions (i.e. offering short lifespan and minimum capital cost) and has studied the possibility of installing generation means in transformer substations (20 kV). This solution does not require extension of networks since these means are scattered near consumption areas. An experiment conducted on 3 Diesel generators of 800 kWe each at Senlis revealed some of the disadvantages of Diesel (maintenance requirements, polluting emissions and noise). EDF then examined, for this same application, the use of gas turbines, for which these drawbacks are significantly less. A study carried out under an EDF contract by the French manufacturer TURBOMECA showed that it is possible to design a small capacity gas turbine that can compete with Diesel generators, and that capital costs could be minimized by simplifying the machine, adapting its lifespan to extreme peak load needs, and taking advantage of lower cost provided by mass production. TURBOMECA defined the machine's characteristics (2 MW, 6 000 hours lifespan) and aerodynamic flow. It also estimated the cost of packaging. In terms of overall cost (including initial investment, maintenance and fuel) the gas turbine appears cheaper than Diesel generators for annual operation times of less than one hundred hours, which corresponds closely with extreme peak load use. The lower maintenance costs and the better availability counterbalance the higher capital cost (+6%) and the greater consumption (+50%). (author). 7 figs

  14. Aerobic exercise capacity at long-term follow-up after paediatric allogeneic haematopoietic SCT

    DEFF Research Database (Denmark)

    Mathiesen, S; Uhlving, H H; Buchvald, F

    2014-01-01

    Peak oxygen uptake (VO2peak), a measure of aerobic exercise capacity, predicts mortality and morbidity in healthy and diseased individuals. Our aim was to determine VO2peak years after paediatric allogeneic haematopoietic SCT (HSCT) and to identify associations with baseline patient and donor...... type or GvHD were found. Although causes for reduced VO2peak may be multiple, our findings stress the need to focus on physical activity post HSCT to prevent lifestyle diseases and improve quality of life....

  15. Peak-interviewet

    DEFF Research Database (Denmark)

    Raalskov, Jesper; Warming-Rasmussen, Bent

    Peak-interviewet er en særlig effektiv metode til at gøre ubevidste menneskelige ressourcer bevidste. Fokuspersonen (den interviewede) interviewes om en selvvalgt, personlig succesoplevelse. Terapeuten/coachen (intervieweren) spørger ind til processen, som ledte hen til denne succes. Herved afdæk...... fokuspersonen ønsker at tage op (nye mål eller nye processer). Nærværende workingpaper beskriver, hvad der menes med et peak-interview, peakinterviwets teoretiske fundament samt metodikken til at foretage et tillidsfuldt og effektiv peak-interview....

  16. Natural gas productive capacity for the lower 48 states, 1982--1993

    International Nuclear Information System (INIS)

    1993-01-01

    The purpose of this report is to analyze monthly natural gas wellhead productive capacity and project this capacity for 1992 and 1993, based upon historical production data through 1991. Productive capacity is the volume of gas that can be produced from a well, reservoir, or field during a given period of time against a certain wellhead back-pressure under actual reservoir conditions excluding restrictions imposed by pipeline capacity, contracts, or regulatory bodies. For decades, natural gas supplies and productive capacity have been adequate, although in the 1970's the capacity surplus was small because of market structure (both interstate and intrastate), increasing demand, and insufficient drilling. In the early 1980's, lower demand together with increased drilling led to a large surplus of natural gas capacity. After 1986, this large surplus began to decline as demand for gas increased, gas prices dropped, and gas well completions dropped sharply. In late December 1989, this surplus decline, accompanied by exceptionally high demand and temporary weather-related production losses, led to concerns about the adequacy of monthly productive capacity for natural gas. This study indicates that monthly productive capacity will drop sharply during the 1992-1993 period. In the low gas price, low drilling case, gas productive capacity and estimated production demand will be roughly equal in December 1993. In base and high drilling cases, monthly productive capacity should be able to meet normal production demands through 1993 in the lower 48 States. Exceptionally high peak-day or peak-week production demand might not be met because of physical limitations. Beyond 1993, as the capacity of currently producing wells declines, a sufficient number of wells and/or imports must be added each year in order to ensure an adequate gas supply

  17. Valence of wind power, photovoltaic and peak-load power plants as a part of the entire electricity system

    International Nuclear Information System (INIS)

    Schüppel, A.

    2014-01-01

    The transition to a higher share of renewable energy sources in the electricity sector leads to a multitude of challenges for the current electricity system. Within this thesis, the development of wind power and photovoltaics generation capacities in Germany is analysed based on the evaluation of technical and economic criteria. In order to derive those criteria, different scenarios with a separated and combined increase of wind and photovoltaics capacity are simulated using the model ATLANTIS. The results are compared to a reference scenario without additional wind and PV capacities. Furthermore, the value and functionality of the energy only market based on economic methods, as well as the value of peak load power plants based on opportunity costs are determined. The results of this thesis show, that the current market system is able to gain an additional annual welfare of four to six billion Euro at the best. This result shows that the task of optimising the power plant dispatch is well fulfilled by the current market design. However, the effects, e.g. fuel costs, which may influence this margin. The value of wind power and photovoltaics within the overall electricity system can be derived from the effort which is necessary to integrate these generation technologies into the existing system, and the changes in total costs of electricity generation. Based on the evaluation of time dependencies (seasonality of energy yield from wind and PV) as well as the development of total generation costs, the conclusion can be drawn that wind power is the more suitable RES generation technology for Germany. However, when it comes to grid integration measures, PV shows better results due to a higher generation potential in Southern Germany, which leads to a higher degree of utilisation. Therefore, there is no need to transport electricity from Northern to Southern Germany as it is the case with wind power. A common expansion of wind power and photovoltaics even shows slight

  18. 'Peak oil' or 'peak demand'?

    International Nuclear Information System (INIS)

    Chevallier, Bruno; Moncomble, Jean-Eudes; Sigonney, Pierre; Vially, Rolland; Bosseboeuf, Didier; Chateau, Bertrand

    2012-01-01

    This article reports a workshop which addressed several energy issues like the objectives and constraints of energy mix scenarios, the differences between the approaches in different countries, the cost of new technologies implemented for this purposes, how these technologies will be developed and marketed, which will be the environmental and societal acceptability of these technical choices. Different aspects and issues have been more precisely presented and discussed: the peak oil, development of shale gases and their cost (will non conventional hydrocarbons modify the peak oil and be socially accepted?), energy efficiency (its benefits, its reality in France and other countries, its position in front of the challenge of energy transition), and strategies in the transport sector (challenges for mobility, evolution towards a model of sustainable mobility)

  19. Total antioxidative capacity and zinc concentration in dogs suffering from perianal tumours

    Directory of Open Access Journals (Sweden)

    Brodzki Adam

    2015-09-01

    Full Text Available The aim of the study was to determine total antioxidative capacity (TAC and zinc concentration in serum of dogs suffering from perianal tumours just before the start of the antihormonal treatment (AHT and one and six months later. The study was performed on 45 dogs divided into two groups: control group suffering from non-malignant tumours (N = 24 and a group with malignant neoplastic changes (N = 21. Serum TAC and zinc concentrations were measured using photometric and atomic absorption spectrophotometric methods. Six months after the start of the AHT, TAC was significantly lower by 10.6% in dogs with malignant tumours when compared to controls (P = 0.03. In the non-malignant group, serum zinc concentration was higher before the treatment than in the malignant group, while the opposite results were observed six months later (P < 0.001. In the non-malignant group, gradually decreasing values of serum zinc concentration at each stage of the investigation were observed, while the opposite results were obtained in the malignant group (P < 0.05. The obtained results indicate that malignant neoplastic process is associated with significantly reduced TAC. Determination of serum zinc concentration in dogs with non-malignant and malignant perianal tumours may have practical diagnostic and prognostic values and may serve towards increasing the effectiveness of AHT monitoring.

  20. [Effect of Earth magnetic field on circadian rhythm of total antioxidant capacity of human saliva in the North].

    Science.gov (United States)

    Borisenkov, M F

    2007-01-01

    In the inhabitants of the North during increase of geomagnetic activity and during magnetic calm the decrease of amplitude of circadian rhythm of total antioxidant capacity of saliva is observed. The most favorable conditions to display the circadian rhythm are observed at Kp from 0,5 up to 2. The long residing in the North is connected to influence of irregularly varying geomagnetic activity causing disturbance of function of circadian and antioxidant systems that, probably, is one of the reasons of acceleration of process of aging at northerner and of higher risk of occurrence in them the age associated diseases.

  1. Automated Peak Picking and Peak Integration in Macromolecular NMR Spectra Using AUTOPSY

    Science.gov (United States)

    Koradi, Reto; Billeter, Martin; Engeli, Max; Güntert, Peter; Wüthrich, Kurt

    1998-12-01

    A new approach for automated peak picking of multidimensional protein NMR spectra with strong overlap is introduced, which makes use of the program AUTOPSY (automatedpeak picking for NMRspectroscopy). The main elements of this program are a novel function for local noise level calculation, the use of symmetry considerations, and the use of lineshapes extracted from well-separated peaks for resolving groups of strongly overlapping peaks. The algorithm generates peak lists with precise chemical shift and integral intensities, and a reliability measure for the recognition of each peak. The results of automated peak picking of NOESY spectra with AUTOPSY were tested in combination with the combined automated NOESY cross peak assignment and structure calculation routine NOAH implemented in the program DYANA. The quality of the resulting structures was found to be comparable with those from corresponding data obtained with manual peak picking.

  2. Effects of Endurance and Endurance Strength Training on Body Composition and Physical Capacity in Women with Abdominal Obesity

    Science.gov (United States)

    Skrypnik, Damian; Bogdański, Paweł; Mądry, Edyta; Karolkiewicz, Joanna; Ratajczak, Marzena; Kryściak, Jakub; Pupek-Musialik, Danuta; Walkowiak, Jarosław

    2015-01-01

    Aims To compare the effects of endurance training with endurance strength training on the anthropometric, body composition, physical capacity, and circulatory parameters in obese women. Methods 44 women with abdominal obesity were randomized into groups A and B, and asked to perform endurance (A) and endurance strength training (B) for 3 months, 3 times/week, for 60 min. Dual-energy X-ray absorptiometry and Graded Exercise Test were performed before and after training. Results Significant decreases in body mass, BMI, total body fat, total body fat mass, and waist and hip circumference were observed after both types of intervention. Marked increases in total body lean and total body fat-free mass were documented in group B. In both groups, significant increases in peak oxygen uptake, time to exhaustion, maximal work rate, and work rate at ventilatory threshold were accompanied by noticeably decreased resting heart rate, resting systolic blood pressure, and resting and exercise diastolic blood pressure. No significant differences were noticed between groups for the investigated parameters. Conclusion Our findings demonstrate evidence for a favorable and comparable effect of 3-month endurance and endurance strength training on anthropometric parameters, body composition, physical capacity, and circulatory system function in women with abdominal obesity. PMID:25968470

  3. Beyond peak reservoir storage? A global estimate of declining water storage capacity in large reservoirs

    NARCIS (Netherlands)

    Wisser, D.; Frolking, S.; Hagen, Stephen; Bierkens, M.F.P.|info:eu-repo/dai/nl/125022794

    2013-01-01

    Water storage is an important way to cope with temporal variation in water supply anddemand. The storage capacity and the lifetime of water storage reservoirs can besignificantly reduced by the inflow of sediments. A global, spatially explicit assessment ofreservoir storage loss in conjunction with

  4. Effects of dynamic hyperinflation on exercise capacity and quality of life in stable COPD patients.

    Science.gov (United States)

    Zhao, Li; Peng, Liyue; Wu, Baomei; Bu, Xiaoning; Wang, Chen

    2016-09-01

    Dynamic hyperinflation (DH) is an important pathophysiological characteristic of chronic obstructive pulmonary disease (COPD). There is increasing evidence that DH has negative effects on exercise performance and quality of life. The objective of this study was to explore effects of DH on exercise capacity and quality of life in stable COPD patients. Fifty-eight COPD patients and 20 matched healthy individuals underwent pulmonary function test, 6-min walk test and symptom-limited cardiopulmonary exercise test (CPET). End-expiratory lung volume/total lung capacity ratio (EELVmax/TLC) at peak exercise of CPET was evaluated, and EELVmax/TLC ≥ 75% was defined as 'severe dynamic hyperinflation (SDH)'. Of the 58 patients studied, 29 (50.0%) presented with SDH (SDH+ group, EELVmax/TLC 79.60 ± 3.60%), having worse maximal exercise capacity reflected by lower peakload, maximal oxygen uptake (VO2 max), maximal carbon dioxide output (VCO2 max) and maximal minute ventilation (VEmax) than did those without SDH (SDH- group, EELVmax/TLC 67.44 ± 6.53%). The EELVmax/TLC ratio at peak exercise had no association with variables of pulmonary function and 6-min walk distance (6MWD), but correlated inversely with peakload, VO2 max, VCO2 max and VEmax (r = -0.300~-0.351, P < 0.05). Although no significant differences were observed, patients with EELVmax/TLC ≥ 75% tended to have higher COPD assessment test score (15.07 ± 6.55 vs 13.28 ± 6.59, P = 0.303). DH develops variably during exercise and has a greater impact on maximal exercise capacity than 6MWD, even in those with the same extent of pulmonary function impairment at rest. © 2015 John Wiley & Sons Ltd.

  5. Does recombinant human Epo increase exercise capacity by means other than augmenting oxygen transport?

    DEFF Research Database (Denmark)

    Lundby, C; Robach, P; Boushel, R

    2008-01-01

    This study was performed to test the hypothesis that administration of recombinant human erythropoietin (rHuEpo) in humans increases maximal oxygen consumption by augmenting the maximal oxygen carrying capacity of blood. Systemic and leg oxygen delivery and oxygen uptake were studied during...... before rHuEpo treatment). Blood buffer capacity remained unaffected by rHuEpo treatment and hemodilution. The augmented hematocrit did not compromise peak cardiac output. In summary, in healthy humans, rHuEpo increases maximal oxygen consumption due to augmented systemic and muscular peak oxygen delivery....

  6. Contribution to performing gas solutions and the complementarity of energies to address electric peak consumptions

    International Nuclear Information System (INIS)

    2015-01-01

    This article aims at outlining the contribution that gas-based solutions may have for the reduction of the seasonal electricity peak consumption. After having recalled the principles related to electricity peak consumption (daily peak in summer and in winter due to the use of various equipment which lasts few hours, seasonal peak in winter due to the use of electric heating which may last several weeks) and the associated evolution of electricity consumptions over the last years, this article describes the main challenges related to the electric peak consumption: how to maintain the balance in real time between production and consumption. In France, the network manager must use, beside nuclear power stations, thermal productions (gas or coal-based) which result in higher CO 2 emissions. Electricity imports from Germany also degrade the French carbon footprint. Thus, the management of daily and seasonal peaks can be based on three levers of action: to act on supply by developing capacities to face the residual peak, to act on demand by smoothing the load curve by controlling the load of electric equipment, or to act on demand by a global reduction of the thermo-sensitive consumption of electricity

  7. Antioxidant Capacity, Anthocyanins, and Total Phenols of Wild and Cultivated Berries in Chile Capacidad Antioxidante, Antocianinas y Fenoles Totales de Berries Silvestres y Cultivados en Chile

    Directory of Open Access Journals (Sweden)

    Jaime Guerrero C

    2010-12-01

    Full Text Available It is possible to incorporate a lot of natural antioxidants into the human organism by consuming berries which can prevent diseases generated by the action of free radicals. Antioxidants neutralize free radicals and thus protect the organism from the oxidative damage of lipids, proteins, and nucleic acids. Berries stand out as one of the richest sources of antioxidant phytonutrients among various fruits and vegetables. The objective of this research was to determine antioxidant capacity (AC, total anthocyanins (TA, and total phenols (TP of wild and cultivated berries in different localities of La Araucanía and Los Ríos Regions in Chile. These parameters were analyzed by using the free radical 2,2-diphenyl-1-picrylhydrazyl hydrate (DPPH method, pH-differential, and Folin-Ciocalteu method. Percentages of DPPH discoloration of different berries studied were between 67.8% and 95.3% for red sarsaparilla and rosehip, respectively. Maqui berries showed a significantly higher TA content (2240.2 and 1445.3 mg L-1 cyanidin 3-glucoside than other berries, and a mean for all berries of 335.5 mg L-1. Higher phenol content levels were obtained in two cultivars of saskatoon (773.9 and 1001.9 mg L-1 gallic acid and wild rosehip (1457.0 and 1140.4 mg L-1 gallic acid. We conclude that there are significant differences in antioxidant capacity of wild and cultivated Chilean berries in this study which show a strong correlation between AC and TP content.Por medio del consumo de berries es posible incorporar al organismo una gran cantidad de antioxidantes capaces de prevenir múltiples enfermedades generadas por la acción de los radicales libres. Los antioxidantes actúan neutralizando los radicales libres y de esta forma protegen al organismo del daño oxidativo de lípidos, proteínas y ácidos nucleicos. Entre variadas frutas y hortalizas, se destacan los berries como una de las fuentes más ricas en fitonutrientes antioxidantes. El objetivo de esta investigaci

  8. Effects of dietary sweet potato leaf meal on the growth, non-specific immune responses, total phenols and antioxidant capacity in channel catfish (Ictalurus punctatus).

    Science.gov (United States)

    Lochmann, Rebecca T; Islam, Shahidul; Phillips, Harold; Adam, Zelalem; Everette, Jace

    2013-04-01

    Traditional energy sources in catfish diets have become costly, and economical alternatives are needed. Sweet potato leaves are underutilised agricultural by-products that provide energy and substantial amounts of phenols, which affect animal and human health. There is little information on the effects of these compounds on catfish, or the capacity of catfish to accumulate dietary phenols. Catfish enriched with phenols have marketing potential as functional foods. This study investigated the effects of diets with sweet potato leaf meal (SPLM) on growth performance, health and total phenolic compounds in catfish. SPLM was substituted for wheat middlings in three diets fed to groups of juvenile catfish for 10 weeks. Weight gain, feed conversion, survival, alternative complement activity and lysozyme activity were similar among diets. Haematocrit was lower in fish fed diets with SPLM, but within the normal range. Total phenols and antioxidant capacity in the whole body were similar among treatments. SPLM was an effective energy source for catfish up to the maximum level tested (230 g kg(-1) diet). SPLM did not enhance total phenols in catfish, but there were no apparent antinutritional effects of the meal on catfish growth, health or survival. © 2012 Society of Chemical Industry.

  9. Big data prediction of durations for online collective actions based on peak's timing

    Science.gov (United States)

    Nie, Shizhao; Wang, Zheng; Pujia, Wangmo; Nie, Yuan; Lu, Peng

    2018-02-01

    Peak Model states that each collective action has a life circle, which contains four periods of "prepare", "outbreak", "peak", and "vanish"; and the peak determines the max energy and the whole process. The peak model's re-simulation indicates that there seems to be a stable ratio between the peak's timing (TP) and the total span (T) or duration of collective actions, which needs further validations through empirical data of collective actions. Therefore, the daily big data of online collective actions is applied to validate the model; and the key is to check the ratio between peak's timing and the total span. The big data is obtained from online data recording & mining of websites. It is verified by the empirical big data that there is a stable ratio between TP and T; furthermore, it seems to be normally distributed. This rule holds for both the general cases and the sub-types of collective actions. Given the distribution of the ratio, estimated probability density function can be obtained, and therefore the span can be predicted via the peak's timing. Under the scenario of big data, the instant span (how long the collective action lasts or when it ends) will be monitored and predicted in real-time. With denser data (Big Data), the estimation of the ratio's distribution gets more robust, and the prediction of collective actions' spans or durations will be more accurate.

  10. Effect of In Vitro Digestion on the Total Antioxidant Capacity and Phenolic Content of 3 Species of Oregano (Hedeoma patens, Lippia graveolens, Lippia palmeri).

    Science.gov (United States)

    Gutiérrez-Grijalva, Erick Paul; Angulo-Escalante, Miguel Angel; León-Félix, Josefina; Heredia, J Basilio

    2017-12-01

    Oregano phenolic compounds have been studied for their anti-inflammatory properties. Nonetheless, after ingestion, the gastrointestinal environment can affect their antioxidant stability and thus their bioactive properties. To evaluate the effect of in vitro gastrointestinal (GI) digestion on the phenolic compounds of 3 species of oregano (Hedeoma patens, Lippia graveolens, and Lippia palmeri), the total reducing capacity, total flavonoid content, and antioxidant capacity were evaluated before and after in vitro GI digestion. In addition, the phenolic compounds of the 3 oregano species were identified and quantified by UPLC-PDA before and after in vitro GI digestion. It was shown that the reducing capacity, flavonoid content and antioxidant capacity were affected by the GI digestion process. Moreover, the phenolic compounds identified were apigenin-7-glucoside, scutellarein, luteolin, luteolin-7-glucoside, phloridzin and chlorogenic acid, and their levels were affected by the in vitro GI process. Our results showed that the phenolic compounds from these 3 species of oregano are affected by the in vitro digestion process, and this effect is largely attributable to pH changes. These changes can modify the bioavailability and further anti-inflammatory activity of oregano phenolics, and thus, further research is needed. Oregano is a rich source of polyphenols that have shown bioactive properties like anti-inflammatory potential. However, little is known of the gastrointestinal fate of oregano polyphenols which is imperative to fully understand its bioaccessibility. Our results are important to develop new administration strategies which could help protect the antioxidant and anti-inflammatory potential and bioaccessibility of such compounds. © 2017 Institute of Food Technologists®.

  11. Cardiorespiratory Fitness and Peak Torque Differences between Vegetarian and Omnivore Endurance Athletes: A Cross-Sectional Study.

    Science.gov (United States)

    Lynch, Heidi M; Wharton, Christopher M; Johnston, Carol S

    2016-11-15

    In spite of well-documented health benefits of vegetarian diets, less is known regarding the effects of these diets on athletic performance. In this cross-sectional study, we compared elite vegetarian and omnivore adult endurance athletes for maximal oxygen uptake (VO2 max) and strength. Twenty-seven vegetarian (VEG) and 43 omnivore (OMN) athletes were evaluated using VO2 max testing on the treadmill, and strength assessment using a dynamometer to determine peak torque for leg extensions. Dietary data were assessed using detailed seven-day food logs. Although total protein intake was lower among vegetarians in comparison to omnivores, protein intake as a function of body mass did not differ by group (1.2 ± 0.3 and 1.4 ± 0.5 g/kg body mass for VEG and OMN respectively, p = 0.220). VO2 max differed for females by diet group (53.0 ± 6.9 and 47.1 ± 8.6 mL/kg/min for VEG and OMN respectively, p vegetarian endurance athletes' cardiorespiratory fitness was greater than that for their omnivorous counterparts, but that peak torque did not differ between diet groups. These data suggest that vegetarian diets do not compromise performance outcomes and may facilitate aerobic capacity in athletes.

  12. Ergodic Capacity of Cognitive Radio Under Imperfect Channel-State Information

    KAUST Repository

    Rezki, Zouheir; Alouini, Mohamed-Slim

    2012-01-01

    A spectrum-sharing communication system where the secondary user is aware of the instantaneous channel-state information (CSI) of the secondary link but knows only the statistics and an estimated version of the secondary transmitter-primary receiver link is investigated. The optimum power profile and the ergodic capacity of the secondary link are derived for general fading channels [with a continuous probability density function (pdf)] under the average and peak transmit power constraints and with respect to the following two different interference constraints: 1) an interference outage constraint and 2) a signal-to-interference outage constraint. When applied to Rayleigh fading channels, our results show, for example, that the interference constraint is harmful at the high-power regime, because the capacity does not increase with the power, whereas at the low-power regime, it has a marginal impact and no-interference performance, which corresponds to the ergodic capacity under average or peak transmit power constraint in the absence of the primary user, may be achieved. © 2012 IEEE.

  13. Ergodic Capacity of Cognitive Radio Under Imperfect Channel-State Information

    KAUST Repository

    Rezki, Zouheir

    2012-09-08

    A spectrum-sharing communication system where the secondary user is aware of the instantaneous channel-state information (CSI) of the secondary link but knows only the statistics and an estimated version of the secondary transmitter-primary receiver link is investigated. The optimum power profile and the ergodic capacity of the secondary link are derived for general fading channels [with a continuous probability density function (pdf)] under the average and peak transmit power constraints and with respect to the following two different interference constraints: 1) an interference outage constraint and 2) a signal-to-interference outage constraint. When applied to Rayleigh fading channels, our results show, for example, that the interference constraint is harmful at the high-power regime, because the capacity does not increase with the power, whereas at the low-power regime, it has a marginal impact and no-interference performance, which corresponds to the ergodic capacity under average or peak transmit power constraint in the absence of the primary user, may be achieved. © 2012 IEEE.

  14. Study on tourist carrying capacity of sustainable tourism---by taking Qingliang Mountain in the south-eastern china as an example

    Science.gov (United States)

    Jin, Shenglang; Liu, Ting

    2017-05-01

    This paper analyzed measurable problems of tourist carrying capacity and then studied the corresponding measures by adopting theories and methods of environment sciences. Tourist carrying capacity of Qingliang Mountain was studied by analyzing the system of tourism environment capacity. The results showed that the level of service was 9726, which was smaller than the ecological carrying capacity of 12894. The facilities and spatial capacity were identified as key factors to limit the tourist carrying capacity in Qingliang Mountain. Some advices and measures including newly built and rebuilt basic facilities, construction of management methods for slack and peak tourist season respectively, construction of new sight spot and touring path were discussed to improve the tourist carrying capacity of Qingliang Mountain and solve the problems of overloading of tourists in the peak season.

  15. CO 2 Capture Capacity and Swelling Measurements of Liquid-like Nanoparticle Organic Hybrid Materials via Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy

    KAUST Repository

    Park, Youngjune

    2012-01-12

    Novel nanoparticle organic hybrid materials (NOHMs), which are comprised of organic oligomers or polymers tethered to an inorganic nanosized cores of various sizes, have been synthesized, and their solvating property for CO 2 was investigated using attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy. Simultaneous measurements of CO 2 capture capacity and swelling behaviors of polyetheramine (Jeffamine M-2070) and its corresponding NOHMs (NOHM-I-PE2070) were reported at temperatures of (298, 308, 323 and 353) K and CO 2 pressure conditions ranging from (0 to 5.5) MPa. The polymeric canopy, or polymer bound to the nanoparticle surface, showed significantly less swelling behavior with enhanced or comparable CO 2 capture capacity compared to pure unbound polyetheramine. © 2011 American Chemical Society.

  16. Peak loads and network investments in sustainable energy transitions

    Energy Technology Data Exchange (ETDEWEB)

    Blokhuis, Erik, E-mail: e.g.j.blokhuis@tue.nl [Eindhoven University of Technology, Department of Architecture, Building and Planning, Vertigo 8.11, P.O. Box 513, 5600MB Eindhoven (Netherlands); Brouwers, Bart [Eindhoven University of Technology, Department of Architecture, Building and Planning, Vertigo 8.11, P.O. Box 513, 5600MB Eindhoven (Netherlands); Putten, Eric van der [Endinet, Gas and Electricity Network Operations, P.O. Box 2005, 5600CA Eindhoven (Netherlands); Schaefer, Wim [Eindhoven University of Technology, Department of Architecture, Building and Planning, Vertigo 8.11, P.O. Box 513, 5600MB Eindhoven (Netherlands)

    2011-10-15

    Current energy distribution networks are often not equipped for facilitating expected sustainable transitions. Major concerns for future electricity networks are the possibility of peak load increases and the expected growth of decentralized energy generation. In this article, we focus on peak load increases; the effects of possible future developments on peak loads are studied, together with the consequences for the network. The city of Eindhoven (the Netherlands) is used as reference city, for which a scenario is developed in which the assumed future developments adversely influence the maximum peak loads on the network. In this scenario, the total electricity peak load in Eindhoven is expected to increase from 198 MVA in 2009 to 591-633 MVA in 2040. The necessary investments for facilitating the expected increased peak loads are estimated at 305-375 million Euros. Based upon these projections, it is advocated that - contrary to current Dutch policy - choices regarding sustainable transitions should be made from the viewpoint of integral energy systems, evaluating economic implications of changes to generation, grid development, and consumption. Recently applied and finished policies on energy demand reduction showed to be effective; however, additional and connecting policies on energy generation and distribution should be considered on short term. - Highlights: > Sustainable energy transitions can result in major electricity peak load increases. > Introduction of heat pumps and electrical vehicles requires network expansion. > Under worst case assumptions, peak loads in Eindhoven increase with 200% until 2040. > The necessary investment for facilitating this 2040 peak demand is Euro 305-375 million. > Future policy choices should be made from the viewpoint of the integral energy system.

  17. Peak loads and network investments in sustainable energy transitions

    International Nuclear Information System (INIS)

    Blokhuis, Erik; Brouwers, Bart; Putten, Eric van der; Schaefer, Wim

    2011-01-01

    Current energy distribution networks are often not equipped for facilitating expected sustainable transitions. Major concerns for future electricity networks are the possibility of peak load increases and the expected growth of decentralized energy generation. In this article, we focus on peak load increases; the effects of possible future developments on peak loads are studied, together with the consequences for the network. The city of Eindhoven (the Netherlands) is used as reference city, for which a scenario is developed in which the assumed future developments adversely influence the maximum peak loads on the network. In this scenario, the total electricity peak load in Eindhoven is expected to increase from 198 MVA in 2009 to 591-633 MVA in 2040. The necessary investments for facilitating the expected increased peak loads are estimated at 305-375 million Euros. Based upon these projections, it is advocated that - contrary to current Dutch policy - choices regarding sustainable transitions should be made from the viewpoint of integral energy systems, evaluating economic implications of changes to generation, grid development, and consumption. Recently applied and finished policies on energy demand reduction showed to be effective; however, additional and connecting policies on energy generation and distribution should be considered on short term. - Highlights: → Sustainable energy transitions can result in major electricity peak load increases. → Introduction of heat pumps and electrical vehicles requires network expansion. → Under worst case assumptions, peak loads in Eindhoven increase with 200% until 2040. → The necessary investment for facilitating this 2040 peak demand is Euro 305-375 million. → Future policy choices should be made from the viewpoint of the integral energy system.

  18. Ultrasonic Transducer Peak-to-Peak Optical Measurement

    Directory of Open Access Journals (Sweden)

    Pavel Skarvada

    2012-01-01

    Full Text Available Possible optical setups for measurement of the peak-to-peak value of an ultrasonic transducer are described in this work. The Michelson interferometer with the calibrated nanopositioner in reference path and laser Doppler vibrometer were used for the basic measurement of vibration displacement. Langevin type of ultrasonic transducer is used for the purposes of Electro-Ultrasonic Nonlinear Spectroscopy (EUNS. Parameters of produced mechanical vibration have to been well known for EUNS. Moreover, a monitoring of mechanical vibration frequency shift with a mass load and sample-transducer coupling is important for EUNS measurement.

  19. Increase in plasma total antioxidant capacity of grazing Japanese Black heifers and cows in forestland in Japan.

    Science.gov (United States)

    Haga, Satoshi; Ishizaki, Hiroshi; Nakano, Miwa; Nakao, Seiji; Hirano, Kiyoshi; Yamamoto, Yoshito; Kitagawa, Miya; Sasaki, Hiroyuki; Kariya, Yoshihiro

    2014-02-01

    Blood total antioxidant capacity (TAC) has become a key bio-marker for animal health. Forest-grazing cattle are known to forage various native plants that have high TAC. This study evaluated differences of plasma TAC between forest-grazing (FG) and pasture-grazing cattle (PG). Experiment 1 monitored the plasma TAC levels of 32 Japanese Black cattle. The level in PG did not change throughout the grazing period. However, that in FG, which increased from summer, was significantly higher than that in PG through fall (P trees consumed by FG were higher than those in pasture grasses. Results of this study show that plasma TAC of grazing Japanese Black cattle in forestland increase from summer through fall. © 2013 Japanese Society of Animal Science.

  20. Nonparetic Knee Extensor Strength Is the Determinant of Exercise Capacity of Community-Dwelling Stroke Survivors

    Directory of Open Access Journals (Sweden)

    Wei-Te Wang

    2014-01-01

    Full Text Available Objective. To investigate the relationship among walking speed, exercise capacity, and leg strength in community dwelling stroke subjects and to evaluate which one was the leading determinant factor of them. Design. This is a descriptive, cross-sectional study. Thirty-five chronic stroke patients who were able to walk independently in their community were enrolled. Walking speed was evaluated by using the 12-meter walking test. A maximal exercise test was used to determine the stroke subjects’ exercise capacity. Knee extensor strength, measured as isokinetic torque, was assessed by isokinetic dynamometer. Results. The main walking speed of our subjects was 0.52 m/s. Peak oxygen uptake (VO2 peak was 1.21±0.43 L/min. Knee extensor strength, no matter whether paretic or nonparetic side, was significantly correlated to 12-meter walking speed and exercise capacity. Linear regression also showed the strength of the affected knee extensor was the determinant of walking speed and that of the nonparetic knee extensor was the determinant of exercise capacity in community dwelling stroke subjects. Conclusions. Walking speed and peak oxygen uptake were markedly decreased after stroke. Knee extensor strength of nonparetic leg was the most important determinant of exercise capacity of the community-dwelling stroke subjects. Knee extensor strengthening should be emphasized to help stroke patient to achieve optimal community living.

  1. Nonparetic knee extensor strength is the determinant of exercise capacity of community-dwelling stroke survivors.

    Science.gov (United States)

    Wang, Wei-Te; Huang, Ling-Tzu; Chou, Ya-Hui; Wei, Ta-Sen; Lin, Chung-Che

    2014-01-01

    To investigate the relationship among walking speed, exercise capacity, and leg strength in community dwelling stroke subjects and to evaluate which one was the leading determinant factor of them. This is a descriptive, cross-sectional study. Thirty-five chronic stroke patients who were able to walk independently in their community were enrolled. Walking speed was evaluated by using the 12-meter walking test. A maximal exercise test was used to determine the stroke subjects' exercise capacity. Knee extensor strength, measured as isokinetic torque, was assessed by isokinetic dynamometer. The main walking speed of our subjects was 0.52 m/s. Peak oxygen uptake (VO₂ peak) was 1.21 ± 0.43 L/min. Knee extensor strength, no matter whether paretic or nonparetic side, was significantly correlated to 12-meter walking speed and exercise capacity. Linear regression also showed the strength of the affected knee extensor was the determinant of walking speed and that of the nonparetic knee extensor was the determinant of exercise capacity in community dwelling stroke subjects. Walking speed and peak oxygen uptake were markedly decreased after stroke. Knee extensor strength of nonparetic leg was the most important determinant of exercise capacity of the community-dwelling stroke subjects. Knee extensor strengthening should be emphasized to help stroke patient to achieve optimal community living.

  2. Is Walking Capacity in Subjects with Multiple Sclerosis Primarily Related to Muscle Oxidative Capacity or Maximal Muscle Strength? A Pilot Study

    Directory of Open Access Journals (Sweden)

    Dominique Hansen

    2014-01-01

    Full Text Available Background and Purpose. Walking capacity is reduced in subjects with multiple sclerosis (MS. To develop effective exercise interventions to enhance walking capacity, it is important to determine the impact of factors, modifiable by exercise intervention (maximal muscle strength versus muscle oxidative capacity, on walking capacity. The purpose of this pilot study is to discriminate between the impact of maximal muscle strength versus muscle oxidative capacity on walking capacity in subjects with MS. Methods. From 24 patients with MS, muscle oxidative capacity was determined by calculation of exercise-onset oxygen uptake kinetics (mean response time during submaximal exercise bouts. Maximal muscle strength (isometric knee extension and flexion peak torque was assessed on dynamometer. All subjects completed a 6-minute walking test. Relationships between walking capacity (as a percentage of normal value and muscle strength (of knee flexors and extensors versus muscle oxidative capacity were assessed in multivariate regression analyses. Results. The expanded disability status score (EDSS showed a significant univariate correlation (r=-0.70, P<0.004 with walking capacity. In multivariate regression analyses, EDSS and mean response time, but not muscle strength, were independently related to walking capacity (P<0.05. Conclusions. Walking distance is, next to disability level and not taking neurologic symptoms/deficits into account, primarily related to muscle oxidative capacity in subjects with MS. Additional study is needed to further examine/verify these findings.

  3. Effects of dispersal on total biomass in a patchy, heterogeneous system: analysis and experiment.

    Science.gov (United States)

    Zhang, Bo; Liu, Xin; DeAngelis, Donald L.; Ni, Wei-Ming; Wang, G Geoff

    2015-01-01

    An intriguing recent result from mathematics is that a population diffusing at an intermediate rate in an environment in which resources vary spatially will reach a higher total equilibrium biomass than the population in an environment in which the same total resources are distributed homogeneously. We extended the current mathematical theory to apply to logistic growth and also showed that the result applies to patchy systems with dispersal among patches, both for continuous and discrete time. This allowed us to make specific predictions, through simulations, concerning the biomass dynamics, which were verified by a laboratory experiment. The experiment was a study of biomass growth of duckweed (Lemna minor Linn.), where the resources (nutrients added to water) were distributed homogeneously among a discrete series of water-filled containers in one treatment, and distributed heterogeneously in another treatment. The experimental results showed that total biomass peaked at an intermediate, relatively low, diffusion rate, higher than the total carrying capacity of the system and agreeing with the simulation model. The implications of the experiment to dynamics of source, sink, and pseudo-sink dynamics are discussed.

  4. Capacity adequacy in power markets facing energy transition: A comparison of scarcity pricing and capacity mechanism

    International Nuclear Information System (INIS)

    Petitet, Marie; Finon, Dominique; Janssen, Tanguy

    2017-01-01

    This article analyses how a capacity mechanism can address security of supply objectives in a power market undergoing an energy transition that combines energy efficiency efforts to stabilise demand and a rapid increase in the proportion of renewables. To analyse this situation, power markets are simulated over the long term with a System Dynamics model integrating new investment and closure decisions. This last trait is relevant to studying investment in power generation in mature markets undergoing policy shocks. The energy-only market design with a price cap, with and without a capacity mechanism, is compared to scarcity pricing in two investment behaviour scenarios with and without risk aversion. The results show that the three market designs lead to different levels of risk for peaking unit investment and results thus differ according to which risk aversion hypothesis is adopted. Assuming a risk-neutral investor, the results indicate that compared to an energy-only market with a price cap at 3 000 €/MWh, an energy-only market with scarcity pricing and the market design with a capacity mechanism are two efficient options to reach similar levels of load loss. But under the hypothesis of risk aversion, the results highlight the advantage of the capacity mechanism over scarcity pricing. - Highlights: • Investment decisions in electricity markets are simulated by a System Dynamics model. • Capacity mechanism enhances capacity adequacy compared to the energy-only market. • With no risk aversion, capacity mechanism or scarcity pricing provide similar results. • With risk aversion, capacity mechanism appears to be the preferable market design.

  5. Large abnormal peak on capillary zone electrophoresis due to contrast agent.

    Science.gov (United States)

    Wheeler, Rachel D; Zhang, Liqun; Sheldon, Joanna

    2017-01-01

    Background Some iodinated radio-contrast media absorb ultraviolet light and can therefore be detected by capillary zone electrophoresis. If seen, these peaks are typically small with 'quantifications' of below 5 g/L. Here, we describe the detection of a large peak on capillary zone electrophoresis that was due to the radio-contrast agent, Omnipaque™. Methods Serum from a patient was analysed by capillary zone electrophoresis, and the IgG, IgA, IgM and total protein concentrations were measured. The serum sample was further analysed by gel electrophoresis and immunofixation. Results Capillary zone electrophoresis results for the serum sample showed a large peak with a concentration high enough to warrant urgent investigation. However, careful interpretation alongside the serum immunoglobulin concentrations and total protein concentration showed that the abnormal peak was a pseudoparaprotein rather than a monoclonal immunoglobulin. This was confirmed by analysis with gel electrophoresis and also serum immunofixation. The patient had had a CT angiogram with the radio-contrast agent Omnipaque™; addition of Omnipaque™ to a normal serum sample gave a peak with comparable mobility to the pseudoparaprotein in the patient's serum. Conclusions Pseudoparaproteins can appear as a large band on capillary zone electrophoresis. This case highlights the importance of a laboratory process that detects significant electrophoretic abnormalities promptly and interprets them in the context of the immunoglobulin concentrations. This should avoid incorrect reporting of pseudoparaproteins which could result in the patient having unnecessary investigations.

  6. Natural gas productive capacity for the lower 48 States, 1980 through 1995

    International Nuclear Information System (INIS)

    1994-01-01

    The purpose of this report is to analyze monthly natural gas wellhead productive capacity in the lower 48 States from 1980 through 1992 and project this capacity from 1993 through 1995. For decades, natural gas supplies and productive capacity have been adequate to meet demand. In the 1970's the capacity surplus was small because of market structure (split between interstate and intrastate), increasing demand, and insufficient drilling. In the early 1980's, lower demand, together with increased drilling, led to a large surplus capacity as new productive capacity came on line. After 1986, this large surplus began to decline as demand for gas increased, gas prices fell, and gas well completions dropped sharply. In late December 1989, the decline in this surplus, accompanied by exceptionally high demand and temporary weather-related production losses, led to concerns about the adequacy of monthly productive capacity for natural gas. These concerns should have been moderated by the gas system's performance during the unusually severe winter weather in March 1993 and January 1994. The declining trend in wellhead productive capacity is expected to be reversed in 1994 if natural gas prices and drilling meet or exceed the base case assumption. This study indicates that in the low, base, and high drilling cases, monthly productive capacity should be able to meet normal production demands through 1995 in the lower 48 States (Figure ES1). Exceptionally high peak-day or peak-week production demand might not be met because of physical limitations such as pipeline capacity. Beyond 1995, as the capacity of currently producing wells declines, a sufficient number of wells and/or imports must be added each year in order to ensure an adequate gas supply

  7. Effect of ascorbic acid and dehydration on concentrations of total phenolics, antioxidant capacity, anthocyanins, and color in fruits.

    Science.gov (United States)

    Rababah, Taha M; Ereifej, Khalil I; Howard, L

    2005-06-01

    The purpose of this investigation was to report on the total phenolics, anthocyanins, and oxygen radical absorbance capacity (ORAC) of strawberry, peach, and apple, the influence of dehydration and ascorbic acid treatments on the levels of these compounds, and the effect of these treatments on fruit color. Results showed that fresh strawberry had the highest levels for total phenolics [5317.9 mg of chlorogenic acid equivalents (CAE)/kg], whereas lower levels were found in fresh apple and peach (3392.1 and 1973.1 mg of CAE/kg, respectively), and for anthocyanins (138.8 mg/kg), whereas lower levels were found in fresh apple and peaches (11.0 and 18.9 mg/kg, respectively; fresh strawberry had an ORAC value of 62.9 mM/kg Trolox equivalents. The fresh apple and peach were found to have ORAC values of 14.7 and 11.4 mM/kg of Trolox equivalents, respectively. The color values indicated that the addition of 0.1% ascorbic acid increased the lightness (L) and decreased the redness (a) and yellowness (b) color values of fresh strawberry, peach, and apple, sliced samples, and the puree made from them. Also, results showed that dehydration is a good method to keep the concentrations of total phenolics and anthocyanins and ORAC values at high levels.

  8. A three-month longitudinal study of changes in day/night serum total antioxidant capacity in paranoid schizophrenia.

    Science.gov (United States)

    Morera-Fumero, Armando L; Díaz-Mesa, Estefanía; Abreu-Gonzalez, Pedro; Fernandez-Lopez, Lourdes; Guillen-Pino, Fernando

    2017-01-01

    Free radicals and an oxidant/antioxidant imbalance have been involved in the schizophrenia pathophysiology. The total antioxidant capacity (TAC) is a measure of the antioxidant capacity of a system. Day/night changes are a biological characteristic of hormones such as melatonin or cortisol. There is little information about TAC day/night changes in schizophrenia patients. The aim of this research is to study if there are day/night changes in serum TAC levels of schizophrenia patients. Thirty-two DSM-IV schizophrenia paranoid patients were studied. Blood was sampled at 12:00 and 00:00 h at admission, discharge and three months after hospital discharge (TMAHD). TAC results are expressed as mmol of Trolox/L. Patients did not have day/night TAC differences at admission (12:00: 0.67±0.12 vs. 00:00: 0.61±0.14, p>0.14) or discharge (12:00: 0.65±0.15 vs. 00:00: 0.65±0.12, p>0.99). At TMHD, patients had significantly higher TAC levels at midday than midnight (12:00: 0.83±0.10 vs. 00:00: 0.74±0.12, pday/night serum TAC changes when clinically relapsed and the normalization of day/night serum TAC changes at TMHD can be considered as a biological marker of schizophrenia evolution.

  9. A new interpretation of SAXS peaks in sulfonated poly(ether ether ketone) (sPEEK) membranes for fuel cells.

    Science.gov (United States)

    Mendil-Jakani, H; Zamanillo Lopez, I; Legrand, P M; Mareau, V H; Gonon, L

    2014-06-21

    The structure of a commercial sulfonated poly(ether ether ketone) (sPEEK) membrane was analyzed by Small-Angle X-Ray Scattering (SAXS) for different water uptakes obtained after immersion in liquid water at various temperatures. For low membrane swelling, the SAXS profile displays only a wide-angle peak in the 0.2-0.3 Å(-1) region. As the membrane swells, two supplementary correlation peaks arise and shift towards small angles, which are the signature of a structural evolution of the membrane, whereas the wide angle peak remains stable. The SAXS spectra of sPEEK membranes can thus display three correlation peaks simultaneously. Therefore we propose a new interpretation of these SAXS spectra which conclude that the two small angle peaks are attributed to the so-called matrix and ionomer peaks and the wide-angle peak is ascribed to the mean separation distance between sulfonic acid groups grafted onto the polymer backbone. This peak attribution implies that the sPEEK nano-phase separation is triggered by an immersion in hot water (ionomer peak apparition). Our new peak attribution was confirmed by studying the impact of temperature, electron density contrast and ionic exchange capacity.

  10. Effect of drying methods on total antioxidant capacity of bitter gourd (momordica charantia) fruit

    Science.gov (United States)

    Tan, Ee Shian; Abdullah, Aminah; Maskat, Mohammad Yusof

    2013-11-01

    The effect of thermal and non-thermal drying methods on hydrophilic and lipophilic antioxidant capacities of bitter gourd fruit was investigated in this study. The bitter gourd fruits were dried by following methods: (i) oven drying 40°C, (ii) oven drying 50°C, (iii) oven drying 60°C, (iv) microwave drying (medium low power), (v) microwave drying (medium power) and (vi) freeze drying. Pure acetone and hexane were used to extract the hydrophilic and lipophilic antioxidant compounds from dried bitter gourd fruits. Freeze dried extracts reported to have highest values in DPPH scavenging activity (hydrophilic and lipophilic fractions), FRAP (lipophilic fraction) and TPC (hydrophilic and lipophilic fraction). Thermal drying slightly increased the values of DPPH scavenging activity, FRAP and TPC assays for hydrophilic extracts. Results concluded bitter gourd fruit is a good source of natural antioxidants and its total antioxidant quality was most preserved by freeze drying. Additionally, the higher value reported in DPPH scavenging activity, FRAP and TPC assays for lipophilic extracts than the hydrophilic extracts suggested that the lipophilic antioxidant compounds of bitter gourd fruit might possess stronger antioxidant power than its counterpart.

  11. Evaluation of the impact of peak description on the quantitative capabilities of comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Place, Benjamin J; Morris, Mallory J; Phillips, Melissa M; Sander, Lane C; Rimmer, Catherine A

    2014-11-14

    Comprehensive, two-dimensional liquid chromatography (LC × LC) is a powerful technique for the separation of complex mixtures. Most studies using LC × LC are focused on qualitative efforts, such as increasing peak capacity. The present study examined the use of LC × LC-UV/vis for the separation and quantitation of polycyclic aromatic hydrocarbons (PAHs). More specifically, this study evaluated the impact of different peak integration approaches on the quantitative performance of the LC × LC method. For well-resolved three-dimensional peaks, parameters such as baseline definition, peak base shape, and peak width determination did not have a significant impact on accuracy and precision. For less-resolved peaks, a dropped baseline and the summation of all slices in the peak improved the accuracy and precision of the integration methods. The computational approaches to three-dimensional peak integration are provided, including fully descriptive, select slice, and summed heights integration methods, each with its own strengths and weaknesses. Overall, the integration methods presented quantify each of the PAHs within acceptable precision and accuracy ranges and have comparable performance to that of single dimension liquid chromatography. Published by Elsevier B.V.

  12. Aerobic capacity of Peruvian Quechua: a test of the developmental adaptation hypothesis.

    Science.gov (United States)

    Kiyamu, Melisa; Rivera-Chira, María; Brutsaert, Tom D

    2015-03-01

    High altitude natives are reported to have outstanding work capacity in spite of the challenge of oxygen transport and delivery in hypoxia. To evaluate the developmental effect of lifelong exposure to hypoxia on aerobic capacity, VO2peak was measured on two groups of Peruvian Quechua subjects (18-35 years), who differed in their developmental exposure to altitude. Male and female volunteers were recruited in Lima, Peru (150 m), and were divided in two groups, based on their developmental exposure to hypoxia, those: a) Born at sea-level individuals (BSL), with no developmental exposure to hypoxia (n = 34) and b) Born at high-altitude individuals (BHA) with full developmental exposure to hypoxia (n = 32), but who migrated to sea-level as adults (>16-years-old). Tests were conducted both in normoxia (BP = 750 mm Hg) and normobaric hypoxia at sea-level (BP = 750 mm Hg, FiO2  = 0.12, equivalent to 4,449 m), after a 2-month training period (in order to control for initial differences in physical fitness) at sea-level. BHA had a significantly higher VO2peak at hypoxia (40.31 ± 1.0 ml/min/kg) as compared to BSL (35.78 ± 0.96 ml/min/kg, P = 0.001), adjusting for sex. The decrease of VO2peak at HA relative to SL (ΔVO2peak ) was not different between groups, controlling for baseline levels (VO2peak at sea-level) and sex (BHA = 0.35 ± 0.04 l/min, BSL = 0.44 ± 0.04 l/min; P = 0.12). Forced vital capacity (controlling for height) and the residuals of VO2peak (controlling for weight) had a significant association in the BHA group only (r = 0.155; P = 0.031). In sum, results indicate that developmental exposure to altitude constitutes an important factor to determine superior exercise performance. © 2014 Wiley Periodicals, Inc.

  13. Chronocoulometry of wine on multi-walled carbon nanotube modified electrode: Antioxidant capacity assay.

    Science.gov (United States)

    Ziyatdinova, Guzel; Kozlova, Ekaterina; Budnikov, Herman

    2016-04-01

    Phenolic antioxidants of wine were electrochemically oxidized on multi-walled carbon nanotubes modified glassy carbon electrode (MWNT/GCE) in phosphate buffer solution. Three oxidation peaks were observed at 0.39, 0.61 and 0.83V for red dry wine and 0.39, 0.80 and 1.18 V for white dry wine, respectively, using differential pulse voltammetry at pH 4.0. The oxidation potentials for individual phenolic antioxidants confirmed the integral nature of the analytical signals for the wines examined. A one-step chronocoulometric method at 0.83 and 1.18 V for red and white wines, respectively, has been developed for the evaluation of wine antioxidant capacity (AOC). The AOC is expressed in gallic acid equivalents per 1L of wine. The AOC of white wine was significantly less than red wine (386 ± 112 vs. 1224 ± 184, pwine and total antioxidant capacity, based on coulometric titration with electrogenerated bromine (r=0.8957 at n=5 and r=0.8986 at n=4 for red and white wines, respectively). Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Aerobic capacity in children and adolescents with cerebral palsy

    NARCIS (Netherlands)

    Verschuren, Olaf; Takken, Tim

    2010-01-01

    This study described the aerobic capacity [VO(2peak) (ml/kg/min)] in contemporary children and adolescents with cerebral palsy (CP) using a maximal exercise test protocol. Twenty-four children and adolescents with CP classified at Gross Motor Functional Classification Scale (GMFCS) level I or level

  15. Ambient-temperature high damping capacity in TiPd-based martensitic alloys

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Dezhen [Multi-disciplinary Materials Research Center, Frontier Institute of Science and Technology, State Key Laboratory for Mechanical Behavior of Materials, Xi' an Jiaotong University, Xi' an 710049 (China); Theoretical Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Zhou, Yumei, E-mail: zhouyumei@mail.xjtu.edu.cn [Multi-disciplinary Materials Research Center, Frontier Institute of Science and Technology, State Key Laboratory for Mechanical Behavior of Materials, Xi' an Jiaotong University, Xi' an 710049 (China); Ding, Xiangdong [Multi-disciplinary Materials Research Center, Frontier Institute of Science and Technology, State Key Laboratory for Mechanical Behavior of Materials, Xi' an Jiaotong University, Xi' an 710049 (China); Otsuka, Kazuhiro [Ferroic Physics Group, National Institute for Materials Science, Tsukuba 305-0047, Ibaraki (Japan); Lookman, Turab [Theoretical Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Sun, Jun [Multi-disciplinary Materials Research Center, Frontier Institute of Science and Technology, State Key Laboratory for Mechanical Behavior of Materials, Xi' an Jiaotong University, Xi' an 710049 (China); Ren, Xiaobing [Multi-disciplinary Materials Research Center, Frontier Institute of Science and Technology, State Key Laboratory for Mechanical Behavior of Materials, Xi' an Jiaotong University, Xi' an 710049 (China); Ferroic Physics Group, National Institute for Materials Science, Tsukuba 305-0047, Ibaraki (Japan)

    2015-04-24

    Shape memory alloys (SMAs) have attracted considerable attention for their high damping capacities. Here we investigate the damping behavior of Ti{sub 50}(Pd{sub 50−x}D{sub x}) SMAs (D=Fe, Co, Mn, V) by dynamic mechanical analysis. We find that these alloys show remarkably similar damping behavior. There exists a sharp damping peak associated with the B2–B19 martensitic transformation and a high damping plateau (Q{sup −1}~0.02–0.05) over a wide ambient-temperature range (220–420 K) due to the hysteretic twin boundary motion. After doping hydrogen into the above alloys, a new relaxation-type damping peak appears in the martensite phase over 270–360 K. Such a peak is considered to originate from the interaction of hydrogen atoms with twin boundaries and the corresponding damping capacity (Q{sup −1}~0.05–0.09) is enhanced by roughly twice that of the damping plateau for each alloy. Moreover, the relaxation peaks are at higher temperatures for the TiPd-based alloys (270–370 K) than for the TiNi-based alloys (190–260 K). We discuss the influence of hydrogen diffusion, mobility of twin boundaries and hydrogen–twin boundary interaction on the temperature range of the relaxation peak. Our results suggest that a martensite, with appropriate values for twinning shear and hydrogen doping level, provides a route towards developing high damping SMAs for applications in desired temperature ranges.

  16. Ambient-temperature high damping capacity in TiPd-based martensitic alloys

    International Nuclear Information System (INIS)

    Xue, Dezhen; Zhou, Yumei; Ding, Xiangdong; Otsuka, Kazuhiro; Lookman, Turab; Sun, Jun; Ren, Xiaobing

    2015-01-01

    Shape memory alloys (SMAs) have attracted considerable attention for their high damping capacities. Here we investigate the damping behavior of Ti 50 (Pd 50−x D x ) SMAs (D=Fe, Co, Mn, V) by dynamic mechanical analysis. We find that these alloys show remarkably similar damping behavior. There exists a sharp damping peak associated with the B2–B19 martensitic transformation and a high damping plateau (Q −1 ~0.02–0.05) over a wide ambient-temperature range (220–420 K) due to the hysteretic twin boundary motion. After doping hydrogen into the above alloys, a new relaxation-type damping peak appears in the martensite phase over 270–360 K. Such a peak is considered to originate from the interaction of hydrogen atoms with twin boundaries and the corresponding damping capacity (Q −1 ~0.05–0.09) is enhanced by roughly twice that of the damping plateau for each alloy. Moreover, the relaxation peaks are at higher temperatures for the TiPd-based alloys (270–370 K) than for the TiNi-based alloys (190–260 K). We discuss the influence of hydrogen diffusion, mobility of twin boundaries and hydrogen–twin boundary interaction on the temperature range of the relaxation peak. Our results suggest that a martensite, with appropriate values for twinning shear and hydrogen doping level, provides a route towards developing high damping SMAs for applications in desired temperature ranges

  17. Lower aerobic capacity was associated with abnormal intramuscular energetics in patients with metabolic syndrome

    International Nuclear Information System (INIS)

    Yokota, Takashi; Kinugawa, Shintaro; Okita, Koichi

    2011-01-01

    Lower aerobic capacity is a strong and independent predictor of cardiovascular morbidity and mortality in patients with metabolic syndrome (MetS). However, the mechanisms are not fully elucidated. We tested the hypothesis that skeletal muscle dysfunction could contribute to the lower aerobic capacity in MetS patients. The incremental exercise tests with cycle ergometer were performed in 12 male patients with MetS with no habitual exercise and 11 age-, sex- and activity-matched control subjects to assess the aerobic capacity. We performed 31 phosphorus-magnetic resonance spectroscopy (MRS) to assess the high-energy phosphate metabolism in skeletal muscle during aerobic exercise. Proton-MRS was also performed to measure intramyocellular lipid (IMCL) content. Peak oxygen uptake (peak VO 2 ; 34.1±6.2 vs. 41.4±8.4 ml kg -1 min -1 , P -1 min -1 , P 2 (r=-0.64) and AT (r=-0.60), respectively. IMCL content was threefold higher in MetS and was inversely correlated with peak VO 2 (r=-0.47) and AT (r=-0.52), respectively. Moreover, there was a positive correlation between IMCL content and PCr loss (r=0.64). These results suggested that lean-body aerobic capacity in MetS patients was lower compared with activity-matched healthy subjects, which might be due to the reduced intramuscular fatty acid oxidative metabolism. (author)

  18. Electricity Portfolio Management: Optimal Peak / Off-Peak Allocations

    OpenAIRE

    Huisman, Ronald; Mahieu, Ronald; Schlichter, Felix

    2007-01-01

    textabstractElectricity purchasers manage a portfolio of contracts in order to purchase the expected future electricity consumption profile of a company or a pool of clients. This paper proposes a mean-variance framework to address the concept of structuring the portfolio and focuses on how to allocate optimal positions in peak and off-peak forward contracts. It is shown that the optimal allocations are based on the difference in risk premiums per unit of day-ahead risk as a measure of relati...

  19. Use of the total motile sperm count to predict total fertilization failure in in vitro fertilization

    NARCIS (Netherlands)

    Repping, Sjoerd; van Weert, Janne-Meije; Mol, Ben W. J.; de Vries, Jan W. A.; van der Veen, Fulco

    2002-01-01

    Objective: To evaluate the capacity of baseline characteristics and total motile sperm count (TMC) to predict total fertilization failure (TIFF) in patients undergoing IVF. Design: Retrospective cohort study. Setting: University hospital. Patient(s): Eight hundred ninety-two couples with a total of

  20. Effect of Pistacia Atlantica Extract on Glutathione Peroxidase Tissue Levels and Total Oxidative Capacity of Liver and Plasma Lipid Profile of Rats

    Directory of Open Access Journals (Sweden)

    Parvin Farzanegi

    2013-11-01

    Full Text Available Background: Exercise causes increased oxygen consumption, leaving cells exposed to oxidative stress. Antioxidants may have a protective effect by inhibiting lipid peroxidation. Thus, this study aims to examine the effect of Pistacia atlantica extract on glutathione peroxidase levels and total oxidative capacity of liver and plasma lipid profile of rats. Materials and Methods: In this experimental study, 28 female rats’ weight 155.8±2.7 grams were randomly and equally divided into 4 groups of exercise-saline, control-saline, exercise-mastic, and control-mastic. The exercise groups exercised for 8 weeks (5 days per week, 60 minutes daily, 25 meters per minute, on a zero degree slope. The rats received equal volumes of mastic and saline orally for 4 weeks. Blood and tissue samples were taken 72 hours after the last exercise session. Data were analyzed using one-way variance analysis (ANOVA.Results: Consumption of Pistacia atlantica extract together with endurance exercising for 8 weeks did not significantly affect glutathione peroxidase concentration, total oxidative capacity, LDL, triglyceride, or cholesterol, but significantly reduced HDL (p=0.002.Conclusion: Results showed that antioxidant and lipid profile levels were not affected by consumption of supplements and endurance exercising. However, further studies are required to assess the long term effects of this herbal extract.

  1. CFTR Genotype and Maximal Exercise Capacity in Cystic Fibrosis: A Cross-sectional Study.

    Science.gov (United States)

    Radtke, Thomas; Hebestreit, Helge; Gallati, Sabina; Schneiderman, Jane E; Braun, Julia; Stevens, Daniel; Hulzebos, Erik Hj; Takken, Tim; Boas, Steven R; Urquhart, Don S; Lands, Larry C; Tejero, Sergio; Sovtic, Aleksandar; Dwyer, Tiffany; Petrovic, Milos; Harris, Ryan A; Karila, Chantal; Savi, Daniela; Usemann, Jakob; Mei-Zahav, Meir; Hatziagorou, Elpis; Ratjen, Felix; Kriemler, Susi

    2018-02-01

    Cystic fibrosis transmembrane conductance regulator (CFTR) is expressed in human skeletal muscle cells. Variations of CFTR dysfunction among patients with cystic fibrosis may be an important determinant of maximal exercise capacity in cystic fibrosis. Previous studies on the relationship between CFTR genotype and maximal exercise capacity are scarce and contradictory. This study was designed to explore factors influencing maximal exercise capacity, expressed as peak oxygen uptake (V.O2peak), with a specific focus on CFTR genotype in children and adults with cystic fibrosis. In an international, multicenter, cross-sectional study, we collected data on CFTR genotype and cardiopulmonary exercise tests in patients with cystic fibrosis who were ages 8 years and older. CFTR mutations were classified into functional classes I–V. The final analysis included 726 patients (45% females; age range, 8–61 yr; forced expiratory volume in 1 s, 16 to 123% predicted) from 17 cystic fibrosis centers in North America, Europe, Australia, and Asia, all of whom had both valid maximal cardiopulmonary exercise tests and complete CFTR genotype data. Overall, patients exhibited exercise intolerance (V.O2peak, 77.3 ± 19.1% predicted), but values were comparable among different CFTR classes. We did not detect an association between CFTR genotype functional classes I–III and either V.O2peak (percent predicted) (adjusted β = −0.95; 95% CI, −4.18 to 2.29; P = 0.57) or maximum work rate (Wattmax) (adjusted β = −1.38; 95% CI, −5.04 to 2.27; P = 0.46) compared with classes IV–V. Those with at least one copy of a F508del-CFTR mutation and one copy of a class V mutation had a significantly lower V.O2peak (β = −8.24%; 95% CI, −14.53 to −2.99; P = 0.003) and lower Wattmax (adjusted β = −7.59%; 95% CI, −14.21 to −0.95; P = 0.025) than those with two copies of a class II mutation. On the basis of linear regression analysis adjusted for

  2. Capacity Expansion and Reliability Evaluation on the Networks Flows with Continuous Stochastic Functional Capacity

    Directory of Open Access Journals (Sweden)

    F. Hamzezadeh

    2014-01-01

    Full Text Available In many systems such as computer network, fuel distribution, and transportation system, it is necessary to change the capacity of some arcs in order to increase maximum flow value from source s to sink t, while the capacity change incurs minimum cost. In real-time networks, some factors cause loss of arc’s flow. For example, in some flow distribution systems, evaporation, erosion or sediment in pipes waste the flow. Here we define a real capacity, or the so-called functional capacity, which is the operational capacity of an arc. In other words, the functional capacity of an arc equals the possible maximum flow that may pass through the arc. Increasing the functional arcs capacities incurs some cost. There is a certain resource available to cover the costs. First, we construct a mathematical model to minimize the total cost of expanding the functional capacities to the required levels. Then, we consider the loss of flow on each arc as a stochastic variable and compute the system reliability.

  3. The influence of selenium status on body composition, oxidative DNA damage and total antioxidant capacity in newly diagnosed type 2 diabetes mellitus: A case-control study.

    Science.gov (United States)

    Othman, Fatimah Binti; Mohamed, Hamid Jan Bin Jan; Sirajudeen, K N S; Noh, Mohd Fairulnizal B Md; Rajab, Nor Fadilah

    2017-09-01

    Selenium is involved in the complex system of defense against oxidative stress in diabetes through its biological function of selenoproteins and the antioxidant enzyme. A case-control study was carried out to determine the association of plasma selenium with oxidative stress and body composition status presented in Type 2 Diabetes Mellitus (T2DM) patient and healthy control. This study involved 82 newly diagnosed T2DM patients and 82 healthy controls. Plasma selenium status was determined with Graphite Furnace Atomic Absorption Spectrometry. Body Mass Index, total body fat and visceral fat was assessed for body composition using Body Composition Analyzer (TANITA). Oxidative DNA damage and total antioxidant capacity were determined for oxidative stress biomarker status. In age, gender and BMI adjustment, no significant difference of plasma selenium level between T2DM and healthy controls was observed. There was as a significant difference of Oxidative DNA damage and total antioxidant capacity between T2DM patients and healthy controls with tail DNA% 20.62 [95% CI: 19.71,21.49] (T2DM), 17.67 [95% CI: 16.87,18.56] (control); log tail moment 0.41[95% CI: 0.30,0.52] (T2DM), 0.41[95% CI: 0.30,0.52] (control); total antioxidant capacity 0.56 [95% CI: 0.54,0.58] (T2DM), 0.60 [95% CI: 0.57,0.62] (control). Waist circumference, BMI, visceral fat, body fat and oxidative DNA damage in the T2DM group were significantly lower in the first plasma selenium tertile (38.65-80.90μg/L) compared to the second (80.91-98.20μg/L) and the third selenium tertiles (98.21-158.20μg/L). A similar trend, but not statistically significant, was observed in the control group. Copyright © 2016 Elsevier GmbH. All rights reserved.

  4. PeakForce Tapping resolves individual microvilli on living cells.

    Science.gov (United States)

    Schillers, Hermann; Medalsy, Izhar; Hu, Shuiqing; Slade, Andrea L; Shaw, James E

    2016-02-01

    Microvilli are a common structure found on epithelial cells that increase the apical surface thus enhancing the transmembrane transport capacity and also serve as one of the cell's mechanosensors. These structures are composed of microfilaments and cytoplasm, covered by plasma membrane. Epithelial cell function is usually coupled to the density of microvilli and its individual size illustrated by diseases, in which microvilli degradation causes malabsorption and diarrhea. Atomic force microscopy (AFM) has been widely used to study the topography and morphology of living cells. Visualizing soft and flexible structures such as microvilli on the apical surface of a live cell has been very challenging because the native microvilli structures are displaced and deformed by the interaction with the probe. PeakForce Tapping® is an AFM imaging mode, which allows reducing tip-sample interactions in time (microseconds) and controlling force in the low pico-Newton range. Data acquisition of this mode was optimized by using a newly developed PeakForce QNM-Live Cell probe, having a short cantilever with a 17-µm-long tip that minimizes hydrodynamic effects between the cantilever and the sample surface. In this paper, we have demonstrated for the first time the visualization of the microvilli on living kidney cells with AFM using PeakForce Tapping. The structures observed display a force dependence representing either the whole microvilli or just the tips of the microvilli layer. Together, PeakForce Tapping allows force control in the low pico-Newton range and enables the visualization of very soft and flexible structures on living cells under physiological conditions. © 2015 The Authors Journal of Molecular Recognition Published by John Wiley & Sons Ltd.

  5. 76 FR 35215 - Notice of EPA Workshop on Sanitary Sewer Overflows and Peak Wet Weather Discharges

    Science.gov (United States)

    2011-06-16

    ... maintained sanitary sewer systems are meant to collect and transport all of the sewage that flows into them... sewage from these overflows can contaminate our waters, causing serious water quality problems. It can... influent flows to exceed the treatment capacity of existing secondary treatment units. Known as ``peak...

  6. Seasonal evolution of diffusional limitations and photosynthetic capacity in olive under drought.

    Science.gov (United States)

    Diaz-Espejo, Antonio; Nicolás, Emilio; Fernández, José Enrique

    2007-08-01

    This study tests the hypothesis that diffusional limitation of photosynthesis, rather than light, determines the distribution of photosynthetic capacity in olive leaves under drought conditions. The crowns of four olive trees growing in an orchard were divided into two sectors: one sector absorbed most of the radiation early in the morning (MS) while the other absorbed most in the afternoon (AS). When the peak of radiation absorption was higher in MS, air vapour pressure deficit (VPD) was not high enough to provoke stomatal closure. In contrast, peak radiation absorption in AS coincided with the daily peak in VPD. In addition, two soil water treatments were evaluated: irrigated trees (I) and non-irrigated trees (nI). The seasonal evolution of leaf water potential, leaf gas exchange and photosynthetic capacity were measured throughout the tree crowns in spring and summer. Results showed that stomatal conductance was reduced in nI trees in summer as a consequence of soil water stress, which limited their net assimilation rate. Olive leaves displayed isohydric behaviour and no important differences in the diurnal course of leaf water potentials among treatments and sectors were found. Seasonal diffusional limitation of photosynthesis was mainly increased in nI trees, especially as a result of stomatal limitation, although mesophyll conductance (g(m)) was found to decrease in summer in both treatments and sectors. A positive relationship between leaf nitrogen content with both leaf photosynthetic capacity and the daily integrated quantum flux density was found in spring, but not in summer. The relationship between photosynthetic capacity and g(m) was curvilinear. Leaf temperature also affected to g(m) with an optimum temperature at 29 degrees C. AS showed larger biochemical limitation than MS in August in both treatments. All these suggest that both diffusional limitation and the effect of leaf temperature could be involved in the seasonal reduction of photosynthetic

  7. Effects of dorsal and lateral decubitus on peak expiratory flow in healthy subjects

    Directory of Open Access Journals (Sweden)

    Heloisa H. Gianinis

    2013-10-01

    Full Text Available BACKGROUND: One of the measures of the pulmonary function is the peak expiratory flow (PEF that can be defined as the major flow obtained in an expiratory pressure after a complete inspiration to the level of the total lung capacity. This measure depends on the effort and strength of expiratory muscles, the airway diameter and the lung volume. OBJECTIVE: To compare the results of the peak expiratory flow in healthy male and female obtained in a seated position and dorsal decubitus (DD, right lateral decubitus (RLD and left lateral decubitus (LLD. METHOD: Thirty young subjects with mean age 22.7 years, healthy and non-smokers were included at the study, 15 of male sex. They did spirometry and IPAQ questionnaire to check the normal pulmonary function and physical activity level. The measures of PEF were performed in four positions, being performed 3 measures in which position, in a random order. Statistical analysis was performed according to Student's t test, with significance level set at 5%. RESULTS: There was a difference between the values obtained in sitting position(481±117.1 L/min with DD(453.2±116.3 L/min and RLD (454±112.9 L/min (p<0.05, however, did not find a significant difference between the sitting position and LLD (469±83 L/min. CONCLUSIONS: Body position affects the values of PEF, with decreasing values in DD and RLD. The LLD can be an alternative to optimize the expiratory flow in situations of constraint to the sitting position.

  8. The product of capacities and belief functions

    DEFF Research Database (Denmark)

    Hendon, Ebbe; Whitta-Jacobsen, Hans Jørgen; Sloth, Birgitte

    1996-01-01

    Capacities (monotone, non-additive set functions) have been suggested to describe situations of uncertainty. We examine the question of how to define the product of two independent capacities. In particular, for the product of two belief functions (totally monotone capacities), there is a unique...... minimal product belief function. This is characterized in several ways...

  9. The product of capacities and belief functions

    DEFF Research Database (Denmark)

    Hendon, Ebbe; Jacobsen, Hans Jørgen; Sloth, Birgitte

    1996-01-01

    Capacities (monotone, non-additive set functions) have been suggested to describe situations of uncertainty. We examine the question of how to define the product of two independent capacities. In particular, for the product of two belief functions (totally monotone capacities), there is a unique...... minimal product belief function. This is characterized in several ways....

  10. Total anti-oxidant capacity of saliva in chronic periodontitis patients before and after periodontal treatment.

    Science.gov (United States)

    Shirzaiy, M; Ansari, S M; Dehghan, J H; Ghaeni, S H

    2014-01-01

    Periodontal disease is among the most common inflammatory conditions which is associated with many different factors. One of the contributing factors to the pathogenesis of this condition may compromise the defensive mechanism of antioxidants. The present study evaluates the antioxidant capacity of saliva in periodontal patients before and after periodontal treatment. In this cross sectional study, 31 patients systemically healthy non smokers with chronic periodontitis were recruited. The antioxidant capacity of saliva was measured before the initial phase of periodontal therapy and after completion of the treatment. Data were analyzed using SPSS 19 software. Paired T-Test, Independent sample T-test and ANOVA tests were used as appropriated. The mean and standard deviation antioxidant capacity of the saliva after the treatment.(0.962± 0.287µM)was significantly higher than before the treatment (0.655 ± 0.281 µM ,pperiodontal treatment was higher among men than among women; however, the difference was not significant (P=0.07). The mean difference of salivary antioxidant capacity was not significantly differed among different ages (P=0.772). The antioxidant capacity of saliva was higher after periodontal therapy among patients with periodontal disease, however the change was not varied across the ages and gender. Therefore, the alterations in the defensive mechanism of antioxidants could be the key factors contribute to the pathogenesis of periodontal diseases.

  11. Peak Exercise Oxygen Uptake Predicts Recurrent Admissions in Heart Failure With Preserved Ejection Fraction.

    Science.gov (United States)

    Palau, Patricia; Domínguez, Eloy; Núñez, Eduardo; Ramón, José María; López, Laura; Melero, Joana; Sanchis, Juan; Bellver, Alejandro; Santas, Enrique; Bayes-Genis, Antoni; Chorro, Francisco J; Núñez, Julio

    2018-04-01

    Heart failure with preserved ejection fraction (HFpEF) is a highly prevalent syndrome with an elevated risk of morbidity and mortality. To date, there is scarce evidence on the role of peak exercise oxygen uptake (peak VO 2 ) for predicting the morbidity burden in HFpEF. We sought to evaluate the association between peak VO 2 and the risk of recurrent hospitalizations in patients with HFpEF. A total of 74 stable symptomatic patients with HFpEF underwent a cardiopulmonary exercise test between June 2012 and May 2016. A negative binomial regression method was used to determine the association between the percentage of predicted peak VO 2 (pp-peak VO 2 ) and recurrent hospitalizations. Risk estimates are reported as incidence rate ratios. The mean age was 72.5 ± 9.1 years, 53% were women, and all patients were in New York Heart Association functional class II to III. Mean peak VO 2 and median pp-peak VO 2 were 10 ± 2.8mL/min/kg and 60% (range, 47-67), respectively. During a median follow-up of 276 days [interquartile range, 153-1231], 84 all-cause hospitalizations in 31 patients (41.9%) were registered. A total of 15 (20.3%) deaths were also recorded. On multivariate analysis, accounting for mortality as a terminal event, pp-peak VO 2 was independently and linearly associated with the risk of recurrent admission. Thus, and modeled as continuous, a 10% decrease of pp-peak VO 2 increased the risk of recurrent hospitalizations by 32% (IRR, 1.32; 95%CI, 1.03-1.68; P = .028). In symptomatic elderly patients with HFpEF, pp-peak VO 2 predicts all-cause recurrent admission. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  12. Attenuated increase in maximal force of rat medial gastrocnemius muscle after concurrent peak power and endurance training

    NARCIS (Netherlands)

    Furrer, R.; Jaspers, R.T.; Baggerman, H.L.; Bravenboer, N.; Lips, P.; de Haan, A.

    2013-01-01

    Improvement of muscle peak power and oxidative capacity are generally presumed to be mutually exclusive. However, this may not be valid by using fibre type-specific recruitment. Since rat medial gastrocnemius muscle (GM) is composed of high and low oxidative compartments which are recruited task

  13. Discovery and characterization of the first low-peaked and intermediate-peaked BL Lacertae objects in the very high energy {gamma}-ray regime

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Karsten

    2009-12-19

    20 years after the discovery of the Crab Nebula as a source of very high energy {gamma}-rays, the number of sources newly discovered above 100 GeV using ground-based Cherenkov telescopes has considerably grown, at the time of writing of this thesis to a total of 81. The sources are of different types, including galactic sources such as supernova remnants, pulsars, binary systems, or so-far unidentified accelerators and extragalactic sources such as blazars and radio galaxies. The goal of this thesis work was to search for {gamma}-ray emission from a particular type of blazars previously undetected at very high {gamma}-ray energies, by using the MAGIC telescope. Those blazars previously detected were all of the same type, the so-called high-peaked BL Lacertae objects. The sources emit purely non-thermal emission, and exhibit a peak in their radio-to-X-ray spectral energy distribution at X-ray energies. The entire blazar population extends from these rare, low-luminosity BL Lacertae objects with peaks at X-ray energies to the much more numerous, high-luminosity infrared-peaked radio quasars. Indeed, the low-peaked sources dominate the source counts obtained from space-borne observations at {gamma}-ray energies up to 10 GeV. Their spectra observed at lower {gamma}-ray energies show power-law extensions to higher energies, although theoretical models suggest them to turn over at energies below 100 GeV. This opened the quest for MAGIC as the Cherenkov telescope with the currently lowest energy threshold. In the framework of this thesis, the search was focused on the prominent sources BL Lac, W Comae and S5 0716+714, respectively. Two of the sources were unambiguously discovered at very high energy {gamma}-rays with the MAGIC telescope, based on the analysis of a total of about 150 hours worth of data collected between 2005 and 2008. The analysis of this very large data set required novel techniques for treating the effects of twilight conditions on the data quality

  14. Discovery and characterization of the first low-peaked and intermediate-peaked BL Lacertae objects in the very high energy γ-ray regime

    International Nuclear Information System (INIS)

    Berger, Karsten

    2009-01-01

    20 years after the discovery of the Crab Nebula as a source of very high energy γ-rays, the number of sources newly discovered above 100 GeV using ground-based Cherenkov telescopes has considerably grown, at the time of writing of this thesis to a total of 81. The sources are of different types, including galactic sources such as supernova remnants, pulsars, binary systems, or so-far unidentified accelerators and extragalactic sources such as blazars and radio galaxies. The goal of this thesis work was to search for γ-ray emission from a particular type of blazars previously undetected at very high γ-ray energies, by using the MAGIC telescope. Those blazars previously detected were all of the same type, the so-called high-peaked BL Lacertae objects. The sources emit purely non-thermal emission, and exhibit a peak in their radio-to-X-ray spectral energy distribution at X-ray energies. The entire blazar population extends from these rare, low-luminosity BL Lacertae objects with peaks at X-ray energies to the much more numerous, high-luminosity infrared-peaked radio quasars. Indeed, the low-peaked sources dominate the source counts obtained from space-borne observations at γ-ray energies up to 10 GeV. Their spectra observed at lower γ-ray energies show power-law extensions to higher energies, although theoretical models suggest them to turn over at energies below 100 GeV. This opened the quest for MAGIC as the Cherenkov telescope with the currently lowest energy threshold. In the framework of this thesis, the search was focused on the prominent sources BL Lac, W Comae and S5 0716+714, respectively. Two of the sources were unambiguously discovered at very high energy γ-rays with the MAGIC telescope, based on the analysis of a total of about 150 hours worth of data collected between 2005 and 2008. The analysis of this very large data set required novel techniques for treating the effects of twilight conditions on the data quality. This was successfully achieved

  15. Peak Operation of Cascaded Hydropower Plants Serving Multiple Provinces

    Directory of Open Access Journals (Sweden)

    Jianjian Shen

    2015-10-01

    Full Text Available The bulk hydropower transmission via trans-provincial and trans-regional power networks in China provides great operational flexibility to dispatch power resources between multiple power grids. This is very beneficial to alleviate the tremendous peak load pressure of most provincial power grids. This study places the focus on peak operations of cascaded hydropower plants serving multiple provinces under a regional connected AC/DC network. The objective is to respond to peak loads of multiple provincial power grids simultaneously. A two-stage search method is developed for this problem. In the first stage, a load reconstruction strategy is proposed to combine multiple load curves of power grids into a total load curve. The purpose is to deal with different load features in load magnitudes, peaks and valleys. A mutative-scale optimization method is then used to determine the generation schedules of hydropower plants. In the second stage, an exterior point search method is established to allocate the generation among multiple receiving power grids. This method produces an initial solution using the load shedding algorithm, and further improves it by iteratively coordinating the generation among different power grids. The proposed method was implemented to the operations of cascaded hydropower plants on Xin-Fu River and another on Hongshui River. The optimization results in two cases satisfied the peak demands of receiving provincial power grids. Moreover, the maximum load difference between peak and valley decreased 12.67% and 11.32% in Shanghai Power Grid (SHPG and Zhejiang Power Grid (ZJPG, exceeding by 4.85% and 6.72% those of the current operational method, respectively. The advantage of the proposed method in alleviating peak-shaving pressure is demonstrated.

  16. Projections of US GHG reductions from nuclear power new capacity based on historic levels of investment

    International Nuclear Information System (INIS)

    Besmann, Theodore M.

    2010-01-01

    Historical rates of capital investment in nuclear plant construction were used as a guide to estimate the potential rate of future capacity introduction. The total linear rate of capital expenditure over the entire period of historical construction from 1964 to 1990 was determined to equal $11.5 billion/yr, and that for the period of peak construction from 1973 to 1985 was computed as $17.9 billion/yr, all in 2004$. These values were used with a variety of current capital cost estimates for nuclear construction to obtain several scenarios for possible future nuclear capacity additions. These values were used to obtain the effect of projected nuclear generating capacity on GHG emissions assuming nuclear would directly replace coal-fired generation. It was concluded that actual reductions in emissions would not be experienced until 2038, yet growth in emissions from electrical production would be slowed through that period. Due to the significant time to introduce large-scale changes in the utility sector, nuclear energy cannot have a dramatic short-term effect on emissions. Nuclear power, however, can have a major positive longer term impact, particularly under more favorable cost and investment conditions.

  17. Limitation of peak fitting and peak shape methods for determination of activation energy of thermoluminescence glow peaks

    CERN Document Server

    Sunta, C M; Piters, T M; Watanabe, S

    1999-01-01

    This paper shows the limitation of general order peak fitting and peak shape methods for determining the activation energy of the thermoluminescence glow peaks in the cases in which retrapping probability is much higher than the recombination probability and the traps are filled up to near saturation level. Right values can be obtained when the trap occupancy is reduced by using small doses or by post-irradiation partial bleaching. This limitation in the application of these methods has not been indicated earlier. In view of the unknown nature of kinetics in the experimental samples, it is recommended that these methods of activation energy determination should be applied only at doses well below the saturation dose.

  18. Physical capacity in wheelchair-dependent persons with a spinal cord injury: A critical review of the literature

    NARCIS (Netherlands)

    Haisma, J.A.; van der Woude, L.H.V.; Stam, H.J.; Bergen, M.P.; Sluis, T.A.; Bussmann, J.B.J.

    2006-01-01

    Study design: Review of publications. Objective: To assess the level of physical capacity (peak oxygen uptake, peak power output, muscle strength of the upper extremity and respiratory function) in wheelchair-dependent persons with a spinal cord injury (SCI). Setting: Erasmus MC, University Medical

  19. Physical capacity in wheelchair-dependent persons with a spinal cord injury : a critical review of the literature

    NARCIS (Netherlands)

    Haisma, J. A.; van der Woude, L. H. V.; Stam, H. J.; Bergen, M. P.; Sluis, T. A. R.; Bussmann, J. B. J.

    2006-01-01

    Study design: Review of publications. Objective: To assess the level of physical capacity ( peak oxygen uptake, peak power output, muscle strength of the upper extremity and respiratory function) in wheelchair-dependent persons with a spinal cord injury (SCI). Setting: Erasmus MC, University

  20. Association of obstructive sleep apnea with homocystein, nitric oxide and total antioxidant capacity levels in patients with or without coronary artery disease.

    Science.gov (United States)

    Ortaç Ersoy, Ebru; Fırat, Hikmet; Akaydın, Sevgi; Özkan, Yeşim; Durusu, Mine; Darılmaz Yüce, Gülbahar; Ergün, Recai; Topeli, Arzu; Ardıç, Sadık

    2014-01-01

    Obstructive sleep apnea (OSA) is associated with cardiovascular morbidity and mortality. Deficiency of nitric oxide (NO) and plasma levels of homocystein have been implicated in the pathogenesis of cardiovascular disease. OSA results in oxygen desaturation and arousal from sleep. Free oxygen radicals can be produced by hypoxia-reoxygenation. To test for the hypothesis that OSA is associated with cardiovascular morbidity, we investigated levels of homocystein, NO and total antioxidant capacity in OSA patients with and without coronary artery disease (CAD) in comparison with normal subjects and patients with CAD without OSA. Polysomnography was performed in 27 patients who had a myocardial infarction and in 25 patients without evidence of CAD. Patients were grouped according their polysomnography results as OSA with CAD (group 1), OSA without CAD (group 2), CAD (group 3), and normal (group 4) . Levels of homocystein, NO and total antioxidant capacity were determined after an overnight fasting. Data were analysed with parametric and non parametric statistical tests. According to apnea-hypopnea index (AHI) 44.4% of CAD patients were OSA. After polysomnographic evaluation, the patients were re-distributed as follows: OSA with CAD (n= 12), OSA without CAD (n= 14), CAD (n= 15), and normal (n= 11). Homocystein levels were higher in 3 groups compared to controls. AHI, MDI and desaturation time was higher in three -vessel disease compared to one and two- vessel diseases (p< 0.05). NO levels were correlated with the period of oxygen desaturation (r: -0.45, p= 0.031). The antioxidant capacity did not differ between OSA and healthy groups. OSA is frequent in CAD. AHI, MDI and desaturation time are higher in patients with severe CAD. It is important to evaluate OSA patients for CAD.

  1. Make peak flow a habit

    Science.gov (United States)

    Asthma - make peak flow a habit; Reactive airway disease - peak flow; Bronchial asthma - peak flow ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  2. An Aqueous Redox-Flow Battery with High Capacity and Power: The TEMPTMA/MV System.

    Science.gov (United States)

    Janoschka, Tobias; Martin, Norbert; Hager, Martin D; Schubert, Ulrich S

    2016-11-07

    Redox-flow batteries (RFB) can easily store large amounts of electric energy and thereby mitigate the fluctuating output of renewable power plants. They are widely discussed as energy-storage solutions for wind and solar farms to improve the stability of the electrical grid. Most common RFB concepts are based on strongly acidic metal-salt solutions or poorly performing organics. Herein we present a battery which employs the highly soluble N,N,N-2,2,6,6-heptamethylpiperidinyl oxy-4-ammonium chloride (TEMPTMA) and the viologen derivative N,N'-dimethyl-4,4-bipyridinium dichloride (MV) in a simple and safe aqueous solution as redox-active materials. The resulting battery using these electrolyte solutions has capacities of 54 Ah L -1 , giving a total energy density of 38 Wh L -1 at a cell voltage of 1.4 V. With peak current densities of up to 200 mA cm -2 the TEMPTMA/MV system is a suitable candidate for compact high-capacity and high-power applications. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. World nuclear generating capacity 1993/94

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    This article is the annual summary of world nuclear generating capacity for 1994. A global summary is first provided, reviewing total installed capacity and growth in installed capacity over the next five years. A more detailed discussion of the nuclear efforts in 34 countries follows, with a tabular listing of nuclear projects in each of these countries. The listing includes reactor supplier, reactor type, size, current status, and date of commercial operation

  4. Maximum physical capacity testing in cancer patients undergoing chemotherapy

    DEFF Research Database (Denmark)

    Knutsen, L.; Quist, M; Midtgaard, J

    2006-01-01

    BACKGROUND: Over the past few years there has been a growing interest in the field of physical exercise in rehabilitation of cancer patients, leading to requirements for objective maximum physical capacity measurement (maximum oxygen uptake (VO(2max)) and one-repetition maximum (1RM)) to determin...... early in the treatment process. However, the patients were self-referred and thus highly motivated and as such are not necessarily representative of the whole population of cancer patients treated with chemotherapy....... in performing maximum physical capacity tests as these motivated them through self-perceived competitiveness and set a standard that served to encourage peak performance. CONCLUSION: The positive attitudes in this sample towards maximum physical capacity open the possibility of introducing physical testing...

  5. Water-Constrained Electric Sector Capacity Expansion Modeling Under Climate Change Scenarios

    Science.gov (United States)

    Cohen, S. M.; Macknick, J.; Miara, A.; Vorosmarty, C. J.; Averyt, K.; Meldrum, J.; Corsi, F.; Prousevitch, A.; Rangwala, I.

    2015-12-01

    Over 80% of U.S. electricity generation uses a thermoelectric process, which requires significant quantities of water for power plant cooling. This water requirement exposes the electric sector to vulnerabilities related to shifts in water availability driven by climate change as well as reductions in power plant efficiencies. Electricity demand is also sensitive to climate change, which in most of the United States leads to warming temperatures that increase total cooling-degree days. The resulting demand increase is typically greater for peak demand periods. This work examines the sensitivity of the development and operations of the U.S. electric sector to the impacts of climate change using an electric sector capacity expansion model that endogenously represents seasonal and local water resource availability as well as climate impacts on water availability, electricity demand, and electricity system performance. Capacity expansion portfolios and water resource implications from 2010 to 2050 are shown at high spatial resolution under a series of climate scenarios. Results demonstrate the importance of water availability for future electric sector capacity planning and operations, especially under more extreme hotter and drier climate scenarios. In addition, region-specific changes in electricity demand and water resources require region-specific responses that depend on local renewable resource availability and electricity market conditions. Climate change and the associated impacts on water availability and temperature can affect the types of power plants that are built, their location, and their impact on regional water resources.

  6. Consensus based scheduling of storage capacities in a virtual microgrid

    DEFF Research Database (Denmark)

    Brehm, Robert; Top, Søren; Mátéfi-Tempfli, Stefan

    2017-01-01

    We present a distributed, decentralized method for coordinated scheduling of charge/discharge intervals of storage capacities in a utility grid integrated microgrid. The decentralized algorithm is based on a consensus scheme and solves an optimisation problem with the objective of minimising......, by use of storage capacities, the power flow over a transformer substation from/to the utility grid integrated microgrid. It is shown that when using this coordinated scheduling algorithm, load profile flattening (peak-shaving) for the utility grid is achieved. Additionally, mutual charge...

  7. Peak tree: a new tool for multiscale hierarchical representation and peak detection of mass spectrometry data.

    Science.gov (United States)

    Zhang, Peng; Li, Houqiang; Wang, Honghui; Wong, Stephen T C; Zhou, Xiaobo

    2011-01-01

    Peak detection is one of the most important steps in mass spectrometry (MS) analysis. However, the detection result is greatly affected by severe spectrum variations. Unfortunately, most current peak detection methods are neither flexible enough to revise false detection results nor robust enough to resist spectrum variations. To improve flexibility, we introduce peak tree to represent the peak information in MS spectra. Each tree node is a peak judgment on a range of scales, and each tree decomposition, as a set of nodes, is a candidate peak detection result. To improve robustness, we combine peak detection and common peak alignment into a closed-loop framework, which finds the optimal decomposition via both peak intensity and common peak information. The common peak information is derived and loopily refined from the density clustering of the latest peak detection result. Finally, we present an improved ant colony optimization biomarker selection method to build a whole MS analysis system. Experiment shows that our peak detection method can better resist spectrum variations and provide higher sensitivity and lower false detection rates than conventional methods. The benefits from our peak-tree-based system for MS disease analysis are also proved on real SELDI data.

  8. Oxygen uptake efficiency slope and peak oxygen consumption predict prognosis in children with tetralogy of Fallot.

    Science.gov (United States)

    Tsai, Yun-Jeng; Li, Min-Hui; Tsai, Wan-Jung; Tuan, Sheng-Hui; Liao, Tin-Yun; Lin, Ko-Long

    2016-07-01

    Oxygen uptake efficiency slope (OUES) and peak oxygen consumption (VO2peak) are exercise parameters that can predict cardiac morbidity in patients with numerous heart diseases. But the predictive value in patients with tetralogy of Fallot is still undetermined, especially in children. We evaluated the prognostic value of OUES and VO2peak in children with total repair of tetralogy of Fallot. Retrospective cohort study. Forty tetralogy of Fallot patients younger than 12 years old were recruited. They underwent a cardiopulmonary exercise test during the follow-up period after total repair surgery. The results of the cardiopulmonary exercise test were used to predict the cardiac related hospitalization in the following two years after the test. OUES normalized by body surface area (OUES/BSA) and the percentage of predicted VO2peak appeared to be predictive for two-year cardiac related hospitalization. Receiver operating characteristic curve analysis demonstrated that the best threshold value for OUES/BSA was 1.029 (area under the curve = 0.70, p = 0.03), and for VO2peak was 74% of age prediction (area under the curve = 0.72, p = 0.02). The aforementioned findings were confirmed by Kaplan-Meier plots and log-rank test. OUES/BSA and VO2peak are useful predictors of cardiac-related hospitalization in children with total repair of tetralogy of Fallot. © The European Society of Cardiology 2015.

  9. Effect of Iranian Propolis on Salivary Total Antioxidant Capacity in Gamma-irradiated Rats

    Directory of Open Access Journals (Sweden)

    Sara Aghel

    2014-12-01

    Full Text Available Background and aims. The antioxidant and anti-inflammatory properties of propolis were studied. Since saliva contains antioxidants and radiotherapy of the head and neck mainly affects the saliva, salivary antioxidant defensive mechanism is compromised with oxidative stress produced by radiation therapy. Therefore, the aim of the present study was to investigate the effect of propolis on salivary total antioxidant capacity in irradiated rats. Materials and methods. The study was conducted on 28 rats, 7‒11 weeks of age (160±20 g, divided into four groups: saline with no radiation (S, saline and radiation (SR, propolis with no radiation (P [400 mg/kg IP], propolis and radiation (PR [400 mg/kg IP]. SP and PR were exposed to 15 Gy of gamma irradiation for 7 minutes and 39 seconds. The rats received intraperitoneal injections each day for 10 days, and their tongues and lips were daily examined for mucositis; saliva sample were also taken three times on days 0, 6, and 10. Results. Mucositis incidence appeared to be delayed in the PR compared to the SR, and the severity was significantly higher in the SR compared to the PR. No significant alterations were observed in salivary antioxidant levels during the experiment, except the SR group in which a significant reduction was found. Conclusion. Propolis might reduce and delay radiation-induced mucositis in animal models; it might be able to prevent the reduction in salivary antioxidant levels in irradiated rats as well.

  10. Aerobic Capacity in Children and Adolescents with Cerebral Palsy

    Science.gov (United States)

    Verschuren, Olaf; Takken, Tim

    2010-01-01

    This study described the aerobic capacity [VO[subscript 2peak] (ml/kg/min)] in contemporary children and adolescents with cerebral palsy (CP) using a maximal exercise test protocol. Twenty-four children and adolescents with CP classified at Gross Motor Functional Classification Scale (GMFCS) level I or level II and 336 typically developing…

  11. An analysis of China's CO2 emission peaking target and pathways

    Directory of Open Access Journals (Sweden)

    Jian-Kun He

    2014-12-01

    Full Text Available China has set the goal for its CO2 emissions to peak around 2030, which is not only a strategic decision coordinating domestic sustainable development and global climate change mitigation but also an overarching target and a key point of action for China's resource conservation, environmental protection, shift in economic development patterns, and CO2 emission reduction to avoid climate change. The development stage where China maps out the CO2 emission peak target is earlier than that of the developed countries. It is a necessity that the non-fossil energy supplies be able to meet all the increased energy demand for achieving CO2 emission peaking. Given that China's potential GDP annual increasing rate will be more than 4%, and China's total energy demand will continue to increase by approximately 1.0%–1.5% annually around 2030, new and renewable energies will need to increase by 6%–8% annually to meet the desired CO2 emission peak. The share of new and renewable energies in China's total primary energy supply will be approximately 20% by 2030. At that time, the energy consumption elasticity will decrease to around 0.3, and the annual decrease in the rate of CO2 intensity will also be higher than 4% to ensure the sustained growth of GDP. To achieve the CO2 emission peaking target and substantially promote the low-carbon development transformation, China needs to actively promote an energy production and consumption revolution, the innovation of advanced energy technologies, the reform of the energy regulatory system and pricing mechanism, and especially the construction of a national carbon emission cap and trade system.

  12. Interdependent demands, regulatory constraint, and peak-load pricing. [Assessment of Bailey's model

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, D T; Macgregor-Reid, G J

    1977-06-01

    A model of a regulated firm which includes an analysis of peak-load pricing has been formulated by E. E. Bailey in which three alternative modes of regulation on a profit-maximizing firm are considered. The main conclusion reached is that under a regulation limiting the rate of return on capital investment, price reductions are received solely by peak-users and that when regulation limiting the profit per unit of output or the return on costs is imposed, there are price reductions for all users. Bailey has expressly assumed that the demands in different periods are interdependent but has somehow failed to derive the correct price and welfare implications of this empirically highly relevant assumption. Her conclusions would have been perfectly correct for marginal revenues but are quite incorrect for prices, even if her assumption that price exceeds marginal revenues in every period holds. This present paper derives fully and rigorously the implications of regulation for prices, outputs, capacity, and social welfare for a profit-maximizing firm with interdependent demands. In section II, Bailey's model is reproduced and the optimal conditions are given. In section III, it is demonstrated that under the conditions of interdependent demands assumed by Bailey herself, her often-quoted conclusion concerning the effects of the return-on-investment regulation on the off-peak price is invalid. In section IV, the effects of the return-on-investment regulation on the optimal prices, outputs, capacity, and social welfare both for the case in which the demands in different periods are substitutes and for the case in which they are complements are examined. In section V, the pricing and welfare implications of the return-on-investment regulation are compared with the two other modes of regulation considered by Bailey. Section VI is a summary of all sections. (MCW)

  13. Relationship between vitamin intake and total antioxidant capacity in elderly adults

    OpenAIRE

    Ojeda Arredondo, Myriam Lucia; Pinilla Betancourt, Magda Catalina; Borrero Yoshida, Martha Lucia; Castro Herrera, Vivian Maritza; García Vega, Ángela Sofía; Rodríguez Rodríguez, Juanita Carolina; Sequeda, Gonzalo; Diez, Ofelia; Lucci, Paolo; Salcedo-Reyes, Juan Carlos

    2016-01-01

    Abstract The consumption of foods high in natural antioxidants, like fruits and vegetables, is associated with a lower risk of oxidative stress-related diseases. The aim of this study was to establish the relationship between the plasma antioxidant capacity in adults over fifty and their intake of vitamin A, C, and E. We evaluated 118 24-hour recalls of intake of foods. The intake of vitamin A, C, and E was quantified using food composition tables. We quantified plasma phenols using the Folin...

  14. On Some Statistical Properties of GRBs with Measured Redshifts Having Peaks in Optical Light Curves

    Directory of Open Access Journals (Sweden)

    Grigorii Beskin

    2013-01-01

    Full Text Available We studied the subset of optical light curves of gamma-ray bursts with measured redshifts and well-sampled R band data that have clearly detected peaks. Among 43 such events, 11 are promptoptical peaks (P, coincident with gamma-ray activity, 22 are purely afterglows (A, and 10 more carrythe signatures of an underlying activity (A(U. We studied pair correlations of their gamma-ray andoptical parameters, e.g. total energetics, peak optical luminosities, and durations. The main outcomeof our study is the detection of source frame correlations between both optical peak luminosity and total energy and the redshift for classes A and A(U, and the absence of such a correlation for class Pevents. This result seems to provide evidence of the cosmological evolution of a medium around the burst defining class A and A(U energetics, and the absence of cosmological evolution of the internal properties of GRB engines. We also discuss some other prominent correlations.

  15. Antioxidant Capacities of Fractions of Bamboo Shaving Extract and Their Antioxidant Components.

    Science.gov (United States)

    Gong, Jinyan; Huang, Jun; Xiao, Gongnian; Chen, Feng; Lee, Bolim; Ge, Qing; You, Yuru; Liu, Shiwang; Zhang, Ying

    2016-07-30

    This research was conducted for evaluation of antioxidant activities of four fractions from bamboo shavings extract (BSE) and their antioxidant components. The antioxidant capacities of BSE and four fractions on ABTS, DPPH, FRAP and total antioxidant capacity assays exhibited the following descending order: DF > n-butanol fraction (BF) > BSE ≈ ethyl acetate fraction (AF) > water fraction (WF). Among the identified phenolic compounds, caffeic acid exhibited the highest antioxidant capacities on DPPH, FRAP and total antioxidant capacity assays. An extremely significant positive correlation between the antioxidant activities with the contents of total flavonoids, total phenolic acids, or total phenolics was observed in this study. The result indicated that the bamboo shaving extract and its solvent fractions could act as natural antioxidants in light of their potent antioxidant activities.

  16. Managing Recurrent Congestion of Subway Network in Peak Hours with Station Inflow Control

    OpenAIRE

    Qingru Zou; Xiangming Yao; Peng Zhao; Fei Dou; Taoyuan Yang

    2018-01-01

    Station inflow control (SIC) is an important and effective method for reducing recurrent congestion during peak hours in the Beijing, Shanghai, and Guangzhou subway systems. This work proposes a practical and efficient method for establishing a static SIC scheme in normal weekdays for large-scale subway networks. First, a traffic assignment model without capacity constraint is utilized to determine passenger flow distributions on the network. An internal relationship between station inflows a...

  17. Capacity assessment of concrete containment vessels subjected to aircraft impact

    Energy Technology Data Exchange (ETDEWEB)

    Andonov, Anton, E-mail: anton.andonov@mottmac.com; Kostov, Marin; Iliev, Alexander

    2015-12-15

    Highlights: • An approach to assess the containment capacity to aircraft impact via fragility curves is proposed. • Momentum over Area was defined as most suitable reference parameter to describe the aircraft load. • The effect of the impact induced damages on the containment pressure capacity has been studied. • The studied containment shows no reduction of the pressure capacity for the investigated scenarios. • The effectiveness of innovative protective structure against aircraft impact has been evaluated. - Abstract: The paper describes the procedure and the results from the assessment of the vulnerability of a generic pre-stressed containment structure subjected to a large commercial aircraft impact. Impacts of Boeing 737, Boeing 767 and Boeing 747 have been considered. The containment vulnerability is expressed by fragility curves based on the results of a number of nonlinear dynamic analyses. Three reference parameters have been considered as impact intensity measure in the fragility curve definition: peak impact force (PIF), peak impact pressure (PIP) and Momentum over Area (MoA). Conclusions on the most suitable reference parameter as well on the vulnerability of such containment vessels are drawn. The influence of the aircraft impact induced damages on the containment ultimate pressure capacity is also assessed and some preliminary conclusions on this are drawn. The paper also addresses a conceptual design of a protective structure able to decrease the containment vulnerability and provide a preliminary assessment of the applicability of such concept.

  18. Capacity assessment of concrete containment vessels subjected to aircraft impact

    International Nuclear Information System (INIS)

    Andonov, Anton; Kostov, Marin; Iliev, Alexander

    2015-01-01

    Highlights: • An approach to assess the containment capacity to aircraft impact via fragility curves is proposed. • Momentum over Area was defined as most suitable reference parameter to describe the aircraft load. • The effect of the impact induced damages on the containment pressure capacity has been studied. • The studied containment shows no reduction of the pressure capacity for the investigated scenarios. • The effectiveness of innovative protective structure against aircraft impact has been evaluated. - Abstract: The paper describes the procedure and the results from the assessment of the vulnerability of a generic pre-stressed containment structure subjected to a large commercial aircraft impact. Impacts of Boeing 737, Boeing 767 and Boeing 747 have been considered. The containment vulnerability is expressed by fragility curves based on the results of a number of nonlinear dynamic analyses. Three reference parameters have been considered as impact intensity measure in the fragility curve definition: peak impact force (PIF), peak impact pressure (PIP) and Momentum over Area (MoA). Conclusions on the most suitable reference parameter as well on the vulnerability of such containment vessels are drawn. The influence of the aircraft impact induced damages on the containment ultimate pressure capacity is also assessed and some preliminary conclusions on this are drawn. The paper also addresses a conceptual design of a protective structure able to decrease the containment vulnerability and provide a preliminary assessment of the applicability of such concept.

  19. Peak Experience Project

    Science.gov (United States)

    Scott, Daniel G.; Evans, Jessica

    2010-01-01

    This paper emerges from the continued analysis of data collected in a series of international studies concerning Childhood Peak Experiences (CPEs) based on developments in understanding peak experiences in Maslow's hierarchy of needs initiated by Dr Edward Hoffman. Bridging from the series of studies, Canadian researchers explore collected…

  20. Patterns of changes in wheelchair exercise capacity after spinal cord injury.

    Science.gov (United States)

    van Koppenhagen, Casper F; de Groot, Sonja; Post, Marcel W; Hoekstra, Trynke; van Asbeck, Floris W; Bongers, Helma; Lindeman, Eline; van der Woude, Luc H

    2013-07-01

    (1) To identify different patterns of changes in wheelchair exercise capacity in the period between the start of active spinal cord injury (SCI) rehabilitation and 5 years after discharge; (2) to examine the pattern determinants of the change in wheelchair exercise capacity. Prospective cohort study. Measurements were recorded at the start of active inpatient rehabilitation, 3 months after the start, at discharge of inpatient rehabilitation, 1 year after discharge, and 5 years after discharge. Eight rehabilitation centers. Persons with SCI (N=130; age range, 18-65y), who were wheelchair-dependent, at least for long distances. Not applicable. Wheelchair exercise capacity: peak power output (W). We found 4 different patterns of the change of peak power output (mean ± SD): (1) a pattern with high and progressive scores (33% of total study group): high progressive scores (start of rehabilitation: 49±15W to 5 years after discharge: 77±17.2W); (2) a pattern of improvement during inpatient rehabilitation and deterioration after inpatient rehabilitation (12%): progressive scores during inpatient rehabilitation with deteriorating scores after discharge (start of rehabilitation: 29±8.7W, to discharge: 60±8.4W, to 5 years after discharge: 39±13.1W); (3) a pattern with low and only slightly progressive scores (52%): low progressive scores (start of rehabilitation: 20±10.1W to 5 years after discharge: 31±15.9W); and (4) a pattern with low scores during inpatient rehabilitation and a sharp rise after discharge (3%): low inpatient scores with strong progressive scores after discharge (start of rehabilitation: 29±15.5W to 5 years after discharge: 82±10.6W). A logistic regression of factors that may distinguish between patterns with high and progressive scores and patterns with low and only slightly progressive scores revealed that older age, being a woman, having a tetraplegic lesion, and low functional status were associated with patterns with low and only slightly

  1. Effects of concurrent training on oxidative capacity in rat gastrocnemius muscle

    NARCIS (Netherlands)

    Furrer, R.; Bravenboer, N.; Kos, D.; Lips, P.; de Haan, A.; Jaspers, R.T.

    2013-01-01

    PURPOSE: Training for improvement of oxidative capacity of muscle fibers may be attenuated when concurrently training for peak power. However, because of fiber type-specific recruitment, such attenuation may only account for high-oxidative muscle fibers. Here, we investigate the effects of

  2. Endurance capacity of mice selectively bred for high voluntary wheel running.

    Science.gov (United States)

    Meek, Thomas H; Lonquich, Brian P; Hannon, Robert M; Garland, Theodore

    2009-09-15

    Mice from four lines bred for high voluntary wheel activity run approximately 3-fold more revolutions per day and have elevated maximal oxygen consumption during forced treadmill exercise, as compared with four unselected control (C) lines. We hypothesized that these high runner (HR) lines would have greater treadmill endurance-running capacity. Ninety-six mice from generation 49 were familiarized with running on a motorized treadmill for 3 days. On days 4 and 5, mice were given an incremental speed test (starting at 20 m min(-1), increased 1.5 m min(-1) every 2 min) and endurance was measured as the total time or distance run to exhaustion. Blood samples were taken to measure glucose and lactate concentrations at rest during the photophase, during peak nightly wheel running, and immediately following the second endurance test. Individual differences in endurance time were highly repeatable between days (r=0.79), and mice tended to run longer on the second day (paired t-test, Pwheel running and treadmill endurance differed between the sexes, reinforcing previous studies that indicate sex-specific responses to selective breeding. HR mice appear to have a higher endurance capacity than reported in the literature for inbred strains of mice or transgenics intended to enhance endurance.

  3. A new record peak luminosity for the LHC

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Two weeks of dedicated machine development paid off last weekend when the LHC ran for physics with three nominal intensity (∼1011 protons) bunches in each beam.   This brought a new record peak luminosity of around 8×1029 cm-2 s-1, and allowed the LHC to double the integrated luminosity delivered to the experiments since 30 March from 16 to 32 inverse nanobarns over the weekend. After a few more fills in this configuration, the number of bunches will be raised to six per beam, which will in turn allow the peak luminosity to break the 1030 cm-2 s-1 barrier for the first time, well on the way to achieving the 2010 objective of 1032 cm-2 s-1. This peak luminosity goal requires 800 nominal bunches per beam squeezed to a beta of 3.5 metres. The plan for 2011 is to run the LHC in this configuration over about 10 months, thus achieving the objective of recording one inverse femtobarn of data in total. The machine development period also allowed the TOTEM detectors to be set up with 45...

  4. Antioxidant Capacity of a Turkish Traditional Alcoholic Drink, Raki

    Directory of Open Access Journals (Sweden)

    Yalcin Gorkem

    2016-07-01

    Full Text Available Raki is an aniseed flavoured traditional Turkish alcoholic drink. Antioxidant capacity of raki samples from different commercial brands were evaluated by CUPRAC, DPPH, TEAC and ORAC assays and correlations between these assays and total phenolic content were also investigated. Additionally, the one-way ANOVA and Bonferroni tests were performed to compare differences between values of the samples. Results indicated that different raki samples exhibited different antioxidant capacity and total phenolic content. The mean antioxidant capacity values of samples were in the order of: ORAC>TEAC>CUPRAC>DPPH. The correlations of total phenolic content of samples with their CUPRAC, TEAC and ORAC results were found statistically significant, while DPPH assay showed no significant correlation.

  5. Particle creation by peak electric field

    Energy Technology Data Exchange (ETDEWEB)

    Adorno, T.C. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); Gavrilov, S.P. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); Herzen State Pedagogical University of Russia, Department of General and Experimental Physics, St. Petersburg (Russian Federation); Gitman, D.M. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); P. N. Lebedev Physical Institute, Moscow (Russian Federation); University of Sao Paulo, Institute of Physics, CP 66318, Sao Paulo, SP (Brazil)

    2016-08-15

    The particle creation by the so-called peak electric field is considered. The latter field is a combination of two exponential parts, one exponentially increasing and another exponentially decreasing. We find exact solutions of the Dirac equation with the field under consideration with appropriate asymptotic conditions and calculate all the characteristics of particle creation effect, in particular, differential mean numbers of created particle, total number of created particles, and the probability for a vacuum to remain a vacuum. Characteristic asymptotic regimes are discussed in detail and a comparison with the pure asymptotically decaying field is considered. (orig.)

  6. Feedback-controlled robotics-assisted treadmill exercise to assess and influence aerobic capacity early after stroke: a proof-of-concept study.

    Science.gov (United States)

    Stoller, Oliver; Schindelholz, Matthias; Bichsel, Lukas; Schuster, Corina; de Bie, Rob A; de Bruin, Eling D; Hunt, Kenneth J

    2014-07-01

    The majority of post-stroke individuals suffer from low exercise capacity as a secondary reaction to immobility. The aim of this study was to prove the concept of feedback-controlled robotics-assisted treadmill exercise (RATE) to assess aerobic capacity and guide cardiovascular exercise in severely impaired individuals early after stroke. Subjects underwent constant load and incremental exercise testing using a human-in-the-loop feedback system within a robotics-assisted exoskeleton (Lokomat, Hocoma AG, CH). Inclusion criteria were: stroke onset ≤8 weeks, stable medical condition, non-ambulatory status, moderate motor control of the lower limbs and appropriate cognitive function. Outcome measures included oxygen uptake kinetics, peak oxygen uptake (VO2peak), gas exchange threshold (GET), peak heart rate (HRpeak), peak work rate (Ppeak) and accuracy of reaching target work rate (P-RMSE). Three subjects (18-42 d post-stroke) were included. Oxygen uptake kinetics during constant load ranged from 42.0 to 60.2 s. Incremental exercise testing showed: VO2peak range 19.7-28.8 ml/min/kg, GET range 11.6-12.7 ml/min/kg, and HRpeak range 115-161 bpm. Ppeak range was 55.2-110.9 W and P-RMSE range was 3.8-7.5 W. The concept of feedback-controlled RATE for assessment of aerobic capacity and guidance of cardiovascular exercise is feasible. Further research is warranted to validate the method on a larger scale. Aerobic capacity is seriously reduced in post-stroke individuals as a secondary reaction to immobility. Robotics-assisted walking devices may have substantial clinical relevance regarding assessment and improvement of aerobic capacity early after stroke. Feedback-controlled robotics-assisted treadmill exercise represents a new concept for cardiovascular assessment and intervention protocols for severely impaired individuals.

  7. Plasma total anti-oxidant capacity correlates inversely with the extent of acute appendicitis: a case control study

    Directory of Open Access Journals (Sweden)

    Devay Seda

    2006-03-01

    Full Text Available Abstract Background The role of free oxygen radicals in inflammatory conditions is well known. Free radicals cause lipid peroxidation of cellular membranes resulting in cell death. The purpose of this study was to investigate the levels of total anti-oxidant status (TAS, as a marker of anti-oxidant defense system and malondialdehyde (MDA, as a marker of oxidative stress, in the plasma of patients with acute appendicitis. Methods Fifty-one adult patients with a median age of 31 years who underwent operations with a preoperative diagnosis of acute appendicitis were included in this prospective study. Blood samples for C-reactive protein (CRP, MDA and TAS were collected preoperatively. Groups were compared by using the Mann-Whitney U test. Results There were 27 patients with acute phlagmenous appendicitis and 19 patients with advanced appendicitis (10 gangrenous and 9 perforated appendicitis, while 5 negative explorations were documented. No significant differences in WBC counts and MDA levels between groups were encountered. Plasma CRP was significantly higher in patients with perforated appendicitis, but not in the other groups. In advanced appendicitis group, TAS level was significantly lower than the other groups. On the other hand, plasma TAS level in acute phlagmenous appendicitis group was significantly higher. Conclusion A decrease in plasma total anti-oxidant capacity might be a predictor of the progression of inflammation to the perforation in acute appendicitis.

  8. Apparent heat capacity measurements and thermodynamic functions of D(−)-fructose by standard and temperature-modulated calorimetry

    International Nuclear Information System (INIS)

    Magoń, A.; Pyda, M.

    2013-01-01

    Highlights: ► Experimental, apparent heat capacity of fructose was investigated by advanced thermal analysis. ► Equilibrium melting parameters of fructose were determined. ► Decomposition, superheating of crystalline fructose during melting process were presented. ► TGA, DSC, and TMDSC are useful tools for characterisation of fructose. - Abstract: The qualitative and quantitative thermal analyses of crystalline and amorphous D(−)-fructose were studied utilising methods of standard differential scanning calorimetry (DSC), quasi-isothermal temperature-modulated differential scanning calorimetry (quasi-isothermal TMDSC), and thermogravimetric analysis (TGA). Advanced thermal analysis of fructose was performed based on heat capacity. The apparent total and apparent reversing heat capacities, as well as phase transition parameters were examined on heating and cooling. The melting temperature, T m , of crystalline D(−)-fructose shows a heating rate dependency, which increases with raising the heating rate and leads to superheating. The equilibrium melting temperatures: T m ∘ (onset) = 370 K and T m ∘ (peak) = 372 K, and the equilibrium enthalpy of fusion Δ fus H ° = 30.30 kJ · mol −1 , of crystalline D(−)-fructose were estimated on heating for the results at zero heating rate. Anomalies in the heat capacity in the liquid state of D(−)-fructose, assigned as possible tautomerisation equilibrium, were analysed by DSC and quasi-isothermal TMDSC, both on heating and cooling. Thermal stability of crystals in the region of the melting temperature was examined by TGA and quasi-isothermal TMDSC. Melting, mutarotation, and degradation processes occur simultaneously and there are differences in values of the liquid heat capacity of D(−)-fructose with varied thermal history, measured by quasi-isothermal TMDSC. Annealing of amorphous D(−)-fructose between the glass transition temperature, T g , and the melting temperature, T m , also leads to

  9. Peak Oil and other threatening peaks-Chimeras without substance

    International Nuclear Information System (INIS)

    Radetzki, Marian

    2010-01-01

    The Peak Oil movement has widely spread its message about an impending peak in global oil production, caused by an inadequate resource base. On closer scrutiny, the underlying analysis is inconsistent, void of a theoretical foundation and without support in empirical observations. Global oil resources are huge and expanding, and pose no threat to continuing output growth within an extended time horizon. In contrast, temporary or prolonged supply crunches are indeed plausible, even likely, on account of growing resource nationalism denying access to efficient exploitation of the existing resource wealth.

  10. Simulation of the peak efficiency for a stacked NaI(Tl) spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, H; Murohka, H; Anami, K; Nohtomi, A; Uozumi, Y; Sakae, T; Matoba, M [Kyushu Univ., Fukuoka (Japan). Faculty of Engineering; Koori, N; Maki, T

    1996-07-01

    A stacked NaI(Tl) spectrometer has been developed to measure proton spectra in wide energy range. In the measurement of charged particles with intermediate energy, the detecting efficiency of the spectrometer decreases considerably due to nuclear reactions or out-scattering in the detector material. A Monte Carlo simulation code has been developed to estimate the peak efficiency (peak-to-total ratio) of the spectrometer. The calculated efficiency for intermediate energy is in good agreement with the experimental one. (author)

  11. Total Reducing Capacity in Aquifer Minerals and Sediments: Quantifying the Potential to Attenuate Cr(VI) in Groundwater

    International Nuclear Information System (INIS)

    Sisman, S. Lara

    2015-01-01

    Hexavalent chromium, Cr(VI), is present in the environment as a byproduct of industrial processes. Due to its mobility and toxicity, it is crucial to attenuate or remove Cr(VI) from the environment. The objective of this investigation was to quantify potential natural attenuation, or reduction capacity, of reactive minerals and aquifer sediments. Samples of reduced-iron containing minerals such as ilmenite, as well as Puye Formation sediments representing a contaminated aquifer in New Mexico, were reacted with chromate. The change in Cr(VI) during the reaction was used to calculate reduction capacity. This study found that minerals that contain reduced iron, such as ilmenite, have high reducing capacities. The data indicated that sample history may impact reduction capacity tests due to surface passivation. Further, this investigation identified areas for future research including: a) refining the relationships between iron content, magnetic susceptibility and reduction capacity, and b) long term kinetic testing using fresh aquifer sediments.

  12. Total Reducing Capacity in Aquifer Minerals and Sediments: Quantifying the Potential to Attenuate Cr(VI) in Groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Sisman, S. Lara [Univ. of Virginia, Charlottesville, VA (United States); Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-07-20

    Hexavalent chromium, Cr(VI), is present in the environment as a byproduct of industrial processes. Due to its mobility and toxicity, it is crucial to attenuate or remove Cr(VI) from the environment. The objective of this investigation was to quantify potential natural attenuation, or reduction capacity, of reactive minerals and aquifer sediments. Samples of reduced-iron containing minerals such as ilmenite, as well as Puye Formation sediments representing a contaminated aquifer in New Mexico, were reacted with chromate. The change in Cr(VI) during the reaction was used to calculate reduction capacity. This study found that minerals that contain reduced iron, such as ilmenite, have high reducing capacities. The data indicated that sample history may impact reduction capacity tests due to surface passivation. Further, this investigation identified areas for future research including: a) refining the relationships between iron content, magnetic susceptibility and reduction capacity, and b) long term kinetic testing using fresh aquifer sediments.

  13. Radiobiological basis of total body irradiation with different dose rate and fractionation: repair capacity of hemopoietic cells

    International Nuclear Information System (INIS)

    Song, C.W.; Kim, T.H.; Khan, F.M.; Kersey, J.H.; Levitt, S.H.

    1981-01-01

    Total body irradiation (TBI) followed by bone marrow transplantation is being used in the treatment of malignant or non-malignant hemopoietic disorders. It has been believed that the ability of hemopoietic cells to repair sublethal radiation damage is negligible. Therefore, several schools of investigators suggested that TBI in a single exposure at extremely low dose rate (5 rad/min) over several hours, or in several fractions in 2-3 days, should yield a higher therapeutic gain, as compared with a single exposure at a high dose rate (26 rad/min). We reviewed the existing data in the literature, in particular, the response of hemopoietic cells to fractionated doses of irradiation and found that the repair capacity of both malignant and non-malignant hemopoietic cells might be greater than has been thought. It is concluded that we should not underestimate the ability of hemopoietic cells to repair sublethal radiation damage in using TBI

  14. The fascicular anatomy and peak force capabilities of the sternocleidomastoid muscle.

    Science.gov (United States)

    Kennedy, Ewan; Albert, Michael; Nicholson, Helen

    2017-06-01

    The fascicular morphology of the sternocleidomastoid (SCM) is not well described in modern anatomical texts, and the biomechanical forces it exerts on individual cervical motion segments are not known. The purpose of this study is to investigate the fascicular anatomy and peak force capabilities of the SCM combining traditional dissection and modern imaging. This study is comprised of three parts: Dissection, magnetic resonance imaging (MRI) and biomechanical modelling. Dissection was performed on six embalmed cadavers: three males of age 73-74 years and three females of age 63-93 years. The fascicular arrangement and morphologic data were recorded. MRIs were performed on six young, healthy volunteers: three males of age 24-37 and three females of age 26-28. In vivo volumes of the SCM were calculated using the Cavalieri method. Modelling of the SCM was performed on five sets of computed tomography (CT) scans. This mapped the fascicular arrangement of the SCM with relation to the cervical motion segments, and used volume data from the MRIs to calculate realistic peak force capabilities. Dissection showed the SCM has four parts; sterno-mastoid, sterno-occipital, cleido-mastoid and cleido-occipital portions. Force modelling shows that peak torque capacity of the SCM is higher at lower cervical levels, and minimal at higher levels. Peak shear forces are higher in the lower cervical spine, while compression is consistent throughout. The four-part SCM is capable of producing forces that vary across the cervical motion segments. The implications of these findings are discussed with reference to models of neck muscle function and dysfunction.

  15. High intensity aerobic interval training improves peak oxygen consumption in patients with metabolic syndrome: CAT

    Directory of Open Access Journals (Sweden)

    Alexis Espinoza Salinas

    2014-06-01

    Full Text Available Introduction A number of cardiovascular risk factors characterizes the metabolic syndrome: insulin resistance (IR, low HDL cholesterol and high triglycerides. The aforementioned risk factors lead to elevated levels of abdominal adipose tissue, resulting in oxygen consumption deficiency. Purpose To verify the validity and applicability of using high intensity interval training (HIIT in subjects with metabolic syndrome and to answer the following question: Can HIIT improve peak oxygen consumption? Method The systematic review "Effects of aerobic interval training on exercise capacity and metabolic risk factors in individuals with cardiometabolic disorders" was analyzed. Results Data suggests high intensity aerobic interval training increases peak oxygen consumption by a standardized mean difference of 3.60 mL/kg-1/min-1 (95% confidence interval, 0.28-4.91. Conclusion In spite of the methodological shortcomings of the primary studies included in the systematic review, we reasonably conclude that implementation of high intensity aerobic interval training in subjects with metabolic syndrome, leads to increases in peak oxygen consumption.

  16. A three-month longitudinal study of changes in day/night serum total antioxidant capacity in paranoid schizophrenia.

    Directory of Open Access Journals (Sweden)

    Armando L Morera-Fumero

    Full Text Available Free radicals and an oxidant/antioxidant imbalance have been involved in the schizophrenia pathophysiology. The total antioxidant capacity (TAC is a measure of the antioxidant capacity of a system. Day/night changes are a biological characteristic of hormones such as melatonin or cortisol. There is little information about TAC day/night changes in schizophrenia patients. The aim of this research is to study if there are day/night changes in serum TAC levels of schizophrenia patients. Thirty-two DSM-IV schizophrenia paranoid patients were studied. Blood was sampled at 12:00 and 00:00 h at admission, discharge and three months after hospital discharge (TMAHD. TAC results are expressed as mmol of Trolox/L. Patients did not have day/night TAC differences at admission (12:00: 0.67±0.12 vs. 00:00: 0.61±0.14, p>0.14 or discharge (12:00: 0.65±0.15 vs. 00:00: 0.65±0.12, p>0.99. At TMHD, patients had significantly higher TAC levels at midday than midnight (12:00: 0.83±0.10 vs. 00:00: 0.74±0.12, p<0.006 as it has been reported in healthy subjects. There were no significant TAC differences at 12.00 and 00:00 between admission and discharge. At TMAHD, patients had significantly higher TAC levels than at admission and discharge, both at 12:00 and 00:00 h. In conclusion, the absence of day/night serum TAC changes when clinically relapsed and the normalization of day/night serum TAC changes at TMHD can be considered as a biological marker of schizophrenia evolution.

  17. Achievable peak electrode voltage reduction by neurostimulators using descending staircase currents to deliver charge.

    Science.gov (United States)

    Halpern, Mark

    2011-01-01

    This paper considers the achievable reduction in peak voltage across two driving terminals of an RC circuit when delivering charge using a stepped current waveform, comprising a chosen number of steps of equal duration, compared with using a constant current over the total duration. This work has application to the design of neurostimulators giving reduced peak electrode voltage when delivering a given electric charge over a given time duration. Exact solutions for the greatest possible peak voltage reduction using two and three steps are given. Furthermore, it is shown that the achievable peak voltage reduction, for any given number of steps is identical for simple series RC circuits and parallel RC circuits, for appropriate different values of RC. It is conjectured that the maximum peak voltage reduction cannot be improved using a more complicated RC circuit.

  18. Peak power ratio generator

    Science.gov (United States)

    Moyer, R.D.

    A peak power ratio generator is described for measuring, in combination with a conventional power meter, the peak power level of extremely narrow pulses in the gigahertz radio frequency bands. The present invention in a preferred embodiment utilizes a tunnel diode and a back diode combination in a detector circuit as the only high speed elements. The high speed tunnel diode provides a bistable signal and serves as a memory device of the input pulses for the remaining, slower components. A hybrid digital and analog loop maintains the peak power level of a reference channel at a known amount. Thus, by measuring the average power levels of the reference signal and the source signal, the peak power level of the source signal can be determined.

  19. Required storage capacity to increase the value of renewable energy

    International Nuclear Information System (INIS)

    Nacht, T.

    2014-01-01

    The effort to achieve a more eco - friendly production of energy leads to larger shares of renewables in the electricity sector, resulting in more supply - dependency and volatility. This results in a time shift between production and consumption. In order to gain an upper hand, possibilities for transferring renewable energies from the time of production to the time when the demand occurs are researched. Energy storage systems will play a big role in this process, with pumped storage plants being the most developed and most common technology nowadays. As a first part of this thesis, the renewables in Germany are studied through the use of models on the basis of hourly measured values of the primary energy carriers for the corresponding technology. For these data series many years’ worth of measurements were considered, resulting in data for the hourly production values of the renewable energy sources. The results show a strong dependency between production and the seasons of the year. Furthermore a very small secured contribution of renewable production during times of peak load is registered, leading to the conclusion that energy storages are indeed necessary. Different strategies for the dispatch of the storage technologies pumped hydro storage, compressed air storage and hydrogen storage are developed for the region of Germany, which will be dispatched outside the energy - only market. The different strategies for the storage dispatch have the reduction of the resulting load in common, by preferably transferring renewable energy from times when it is not needed to those times with high loads. This resulting load needs to be covered by thermal power plants. The required capacities of the different storage technologies are evaluated and compared. By using pumped storage plants the increase in the value of renewables, as measured by the secure contribution during peak load hours, is determined. An analysis of different compositions of renewable production allows

  20. Analysis of AC and DC Lighting Systems with 150-Watt Peak Solar Panel in Denpasar Based on NASA Data

    Science.gov (United States)

    Narottama, A. A. N. M.; Amerta Yasa, K.; Suwardana, I. W.; Sapteka, A. A. N. G.; Priambodo, P. S.

    2018-01-01

    Solar energy on the Earth’s surface has different magnitudes on every longitude and latitude. National Aeronautics and Space Administration (NASA) provides surface meteorology and solar energy database which can be accessed openly online. This database delivers information about Monthly Averaged Insolation Incident On A Horizontal Surface, Monthly Averaged Insolation Incident On A Horizontal Surface At Indicated GMT Times and also data about Equivalent Number Of No-Sun Or Black Days for any latitude and longitude. Therefore, we investigate the lighting systems with 150-Watt peak solar panel in Denpasar City, the capital province of Bali. Based on NASA data, we analyse the received wattage by a unit of 150-Watt peak solar panel in Denpasar City and the sustainability of 150-Watt peak solar panel to supply energy for 432-Watt hour/day AC and 360-Watt hour/day DC lighting systems using 1.2 kWh battery. The result shows that the maximum received wattage by a unit of 150-Watt peak solar panel is 0.76 kW/day in October. We concluded that the 1.2 kWh installed battery has higher capacity than the battery capacity needed in March, the month with highest no-sun days, for both AC and DC lighting systems. We calculate that the installed battery can be used to store the sustainable energy from sun needed by AC and DC lighting system for about 2.78 days and 3.51 days, consecutively.

  1. π-π Conjugation Enhances Oligostilbene’s Antioxidant Capacity: Evidence from α-Viniferin and Caraphenol A

    Directory of Open Access Journals (Sweden)

    Xican Li

    2018-03-01

    Full Text Available α-Viniferin and caraphenol A, the two oligostilbenes, have the sole difference of the presence or absence of an exocyclic double bond at the π-π conjugative site. In this study, the antioxidant capacity and relevant mechanisms for α-viniferin and caraphenol A were comparatively explored using spectrophotometry, UV-visible spectral analysis, and electrospray ionization quadrupole time-of-flight tandem mass spectrometry (UPLC–ESI–Q–TOF–MS/MS analysis. The spectrophotometric results suggested that caraphenol A always gave lower IC50 values than α-viniferin in cupric ion-reducing antioxidant capacity assay, ferric-reducing antioxidant power assay, 1,1-diphenyl-2-picryl-hydrazl radical (DPPH•-scavenging, and 2-phenyl-4,4,5,5-tetramethylimidazoline-1-oxyl 3-oxide radical-scavenging assays. In UV-visible spectra analysis, caraphenol A was observed to show enhanced peaks at 250–350 nm when mixed with Fe2+, but α-viniferin exhibited no similar effects. UPLC–ESI–Q–TOF–MS/MS analysis revealed that α-viniferin mixed with DPPH• produced radical adduct formation (RAF peak (m/z = 1070–1072. We conclude that the antioxidant action of α-viniferin and caraphenol A may involve both redox-mediated mechanisms (especially electron transfer and H+-transfer and non-redox-mediated mechanisms (including Fe2+-chelating or RAF. The π-π conjugation of the exocyclic double bond in caraphenol A can greatly enhance the redox-mediated antioxidant mechanisms and partially promote the Fe2+-chelating mechanism. This makes caraphenol A far superior to α-viniferin in total antioxidant levels.

  2. Relating saturation capacity to charge density in strong cation exchangers.

    Science.gov (United States)

    Steinebach, Fabian; Coquebert de Neuville, Bertrand; Morbidelli, Massimo

    2017-07-21

    In this work the relation between physical and chemical resin characteristics and the total amount of adsorbed protein (saturation capacity) for ion-exchange resins is discussed. Eleven different packing materials with a sulfo-functionalization and one multimodal resin were analyzed in terms of their porosity, pore size distribution, ligand density and binding capacity. By specifying the ligand density and binding capacity by the total and accessible surface area, two different groups of resins were identified: Below a ligand density of approx. 2.5μmol/m 2 area the ligand density controls the saturation capacity, while above this limit the accessible surface area becomes the limiting factor. This results in a maximum protein uptake of around 2.5mg/m 2 of accessible surface area. The obtained results allow estimating the saturation capacity from independent resin characteristics like the saturation capacity mainly depends on "library data" such as the accessible and total surface area and the charge density. Hence these results give an insight into the fundamentals of protein adsorption and help to find suitable resins, thus limiting the experimental effort in early process development stages. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Cardiorespiratory fitness of asthmatic children and validation of predicted aerobic capacity

    DEFF Research Database (Denmark)

    Lochte, Lene; Angermann, Marie; Larsson, Benny

    2009-01-01

    : To compare aerobic capacity between asthmatic children and controls, to estimate the agreement between PAC and MAC and observe for trend of PAC. MATERIALS AND METHODS: The design was prospective, 4 years (PAC) and cross-sectional (MAC and VO(2peak)). Non-parametric Wilcoxon rank sums were applied...

  4. The critical role of the routing scheme in simulating peak river discharge in global hydrological models

    Science.gov (United States)

    Zhao, F.; Veldkamp, T.; Frieler, K.; Schewe, J.; Ostberg, S.; Willner, S. N.; Schauberger, B.; Gosling, S.; Mueller Schmied, H.; Portmann, F. T.; Leng, G.; Huang, M.; Liu, X.; Tang, Q.; Hanasaki, N.; Biemans, H.; Gerten, D.; Satoh, Y.; Pokhrel, Y. N.; Stacke, T.; Ciais, P.; Chang, J.; Ducharne, A.; Guimberteau, M.; Wada, Y.; Kim, H.; Yamazaki, D.

    2017-12-01

    Global hydrological models (GHMs) have been applied to assess global flood hazards, but their capacity to capture the timing and amplitude of peak river discharge—which is crucial in flood simulations—has traditionally not been the focus of examination. Here we evaluate to what degree the choice of river routing scheme affects simulations of peak discharge and may help to provide better agreement with observations. To this end we use runoff and discharge simulations of nine GHMs forced by observational climate data (1971-2010) within the ISIMIP2a project. The runoff simulations were used as input for the global river routing model CaMa-Flood. The simulated daily discharge was compared to the discharge generated by each GHM using its native river routing scheme. For each GHM both versions of simulated discharge were compared to monthly and daily discharge observations from 1701 GRDC stations as a benchmark. CaMa-Flood routing shows a general reduction of peak river discharge and a delay of about two to three weeks in its occurrence, likely induced by the buffering capacity of floodplain reservoirs. For a majority of river basins, discharge produced by CaMa-Flood resulted in a better agreement with observations. In particular, maximum daily discharge was adjusted, with a multi-model averaged reduction in bias over about 2/3 of the analysed basin area. The increase in agreement was obtained in both managed and near-natural basins. Overall, this study demonstrates the importance of routing scheme choice in peak discharge simulation, where CaMa-Flood routing accounts for floodplain storage and backwater effects that are not represented in most GHMs. Our study provides important hints that an explicit parameterisation of these processes may be essential in future impact studies.

  5. Association between laboratory capacities and world-cup performance in Nordic combined

    Science.gov (United States)

    Fudel, Ronny; Kocbach, Jan; Moen, Frode; Ettema, Gertjan; Sandbakk, Øyvind

    2017-01-01

    Background Nordic combined (NC) is an Olympic winter-sport performed as a ski jumping (SJ) event followed by a cross-country (XC) pursuit race employing the skating style. Purpose To elucidate the associations between sport-specific laboratory capacities and SJ, XC skiing, and overall NC performance in a world-cup NC event. Methods Twelve international world-cup NC athletes from 8 nations performed laboratory testing one day prior to participating in a world-cup NC event. Squat jumps and SJ imitations (IMIT) were performed on a three-dimensional force plate, whereas XC skiing-specific physiological characteristics were obtained from roller ski skating tests on a treadmill and an all-out double poling (DP) test. Finally, body composition was measured. Laboratory capacities were correlated against performance in SJ, 10-km XC skiing, and overall NC in the world-cup event. Multiple regression analysis was used to determine the best suited laboratory variables for predicting performance. Results Vertical IMIT velocity together with body-mass provided the best prediction for SJ performance (r2 = 0.70, p<0.01), while body-mass-normalized V˙O2peak and DP power provided the best prediction for XC performance (r2 = 0.68, p<0.05). Body-mass-normalized V˙O2peak was the only significant correlate with overall NC performance (r2 = 0.43, p<0.05) in this competition. Conclusion Overall, the concurrent development of V˙O2peak, upper-body power, and SJ-specific vertical jump capacity while minimizing body-mass within the BMI limit set by FIS should be considered in the seasonal training of NC athletes. PMID:28662163

  6. Sodium bicarbonate ingestion and individual variability in time-to-peak pH.

    Science.gov (United States)

    Sparks, Andy; Williams, Emily; Robinson, Amy; Miller, Peter; Bentley, David J; Bridge, Craig; Mc Naughton, Lars R

    2017-01-01

    This study determined variability in time-to-peak pH after consumption of 300 mg kg - 1 of sodium bicarbonate. Seventeen participants (mean ± SD: age 21.38 ± 1.5 years; mass 75.8 ± 5.8 kg; height 176.8 ± 7.6 cm) reported to the laboratory where a resting capillary sample was taken. Then, 300 mg kg -1 of NaHCO 3 in 450 ml of flavoured water was ingested. Participants rested for 90 min and repeated blood samples were procured at 10 min intervals for 60 min and then every 5 min until 90 min. Blood pH concentrations were measured. Results suggested that time-to-peak pH (64.41 ± 18.78 min) was variable with a range of 10-85 min and a coefficient of variation of 29.16%. A bimodal distribution occurred, at 65 and 75 min. In conclusion, athletes, when using NaHCO 3 as an ergogenic aid, should determine their time-to-peak pH to best utilize the added buffering capacity this substance allows.

  7. Antioxidant capacity and physical exercise

    Directory of Open Access Journals (Sweden)

    A Marciniak

    2009-09-01

    Full Text Available The aim of this article is a presentation of current knowledge regarding the changes of plasma antioxidant capacity observed in response to physical exercise. Human body created the enzymatic and non-enzymatic systems, which play a protective role in the harmful impact of free radicals. Those two systems constitute what is known as the plasma total antioxidant capacity. The amount of reactive oxygen species (ROS and reactive nitrogen species (NOS in combination with oxidation processes increases in some tissues during physiological response to physical exercise. These changes are observed after single bout of exercise as well as after regular training. The response of human body to physical exercise can be analysed using various models of exercise test. Application of repeated type of exhaustion allows for characterizing the ability of human body to adjust to the increased energy loss and increased oxygen consumption. This article presents the characteristics of components of plasma antioxidant capacity, the mechanisms of free radicals production and their role in human body. It discusses also the currently used methods of detecting changes in total antioxidant capacity and its individual elements in response to single bout of exercise and regular training. It presents the review of literature about research performed in groups of both regularly training and low exercise activity individuals as well as in group of healthy subjects and patients with circulation diseases.

  8. Exercise capacity before and after an 8-week multidisciplinary inpatient rehabilitation program in lung cancer patients: a pilot study.

    Science.gov (United States)

    Spruit, Martijn A; Janssen, Paul P; Willemsen, Sonja C P; Hochstenbag, Monique M H; Wouters, Emiel F M

    2006-05-01

    Although lung cancer is a highly prevalent type of cancer, the effects of an inpatient multidisciplinary rehabilitation program on pulmonary function and exercise capacity have never been studied in these patients. Pulmonary function, 6-min walking distance and peak exercise capacity of 10 patients with a severely impaired pulmonary function following treatment of lung cancer were assessed in this pilot study before and after an 8-week inpatient multidisciplinary rehabilitation program. At baseline, patients had a restrictive pulmonary function and an apparent exercise intolerance (median 6-min walking distance: 63.6% predicted; median peak cycling load: 58.5% predicted). Despite the lack of change in median pulmonary function [FEV1: -0.01L, p = 0.5469], functional exercise capacity [145 m; 43.2% of the initial values, p=0.0020] and peak exercise capacity [26 W; 34.4% of the initial values, p = 0.0078] improved significantly compared to baseline. Future trials have to corroborate the present findings. Nevertheless, patients with lung cancer have a clear indication to start a comprehensive rehabilitation program following intensive treatment of their disease. In fact, based on the results of the present pilot study it appears that these patients are good candidates for pulmonary rehabilitation programs.

  9. Focused ultrasound transducer spatial peak intensity estimation: a comparison of methods

    Science.gov (United States)

    Civale, John; Rivens, Ian; Shaw, Adam; ter Haar, Gail

    2018-03-01

    Characterisation of the spatial peak intensity at the focus of high intensity focused ultrasound transducers is difficult because of the risk of damage to hydrophone sensors at the high focal pressures generated. Hill et al (1994 Ultrasound Med. Biol. 20 259-69) provided a simple equation for estimating spatial-peak intensity for solid spherical bowl transducers using measured acoustic power and focal beamwidth. This paper demonstrates theoretically and experimentally that this expression is only strictly valid for spherical bowl transducers without a central (imaging) aperture. A hole in the centre of the transducer results in over-estimation of the peak intensity. Improved strategies for determining focal peak intensity from a measurement of total acoustic power are proposed. Four methods are compared: (i) a solid spherical bowl approximation (after Hill et al 1994 Ultrasound Med. Biol. 20 259-69), (ii) a numerical method derived from theory, (iii) a method using measured sidelobe to focal peak pressure ratio, and (iv) a method for measuring the focal power fraction (FPF) experimentally. Spatial-peak intensities were estimated for 8 transducers at three drive powers levels: low (approximately 1 W), moderate (~10 W) and high (20-70 W). The calculated intensities were compared with those derived from focal peak pressure measurements made using a calibrated hydrophone. The FPF measurement method was found to provide focal peak intensity estimates that agreed most closely (within 15%) with the hydrophone measurements, followed by the pressure ratio method (within 20%). The numerical method was found to consistently over-estimate focal peak intensity (+40% on average), however, for transducers with a central hole it was more accurate than using the solid bowl assumption (+70% over-estimation). In conclusion, the ability to make use of an automated beam plotting system, and a hydrophone with good spatial resolution, greatly facilitates characterisation of the FPF, and

  10. Ensuring capacity adequacy during energy transition in mature power markets: a social efficiency comparison of scarcity pricing and capacity mechanism

    International Nuclear Information System (INIS)

    Petitet, Marie; Finon, Dominique; Janssen, Tanguy

    2016-01-01

    This paper analyses how a capacity market mechanism can address security of supply objectives in the case of an energy transition scenario which combines both high energy efficiency efforts which stabilise demand in a context of mature markets and rapid increase of renewables share. The exogenous entry of variable renewables introduces a new challenge in matter of security of supply during peak hours. To analyse this situation, power markets are simulated on the long term with a model based on System Dynamics modelling which integrates both new investment and closure decisions. This last trait is an originality of the model which is very relevant to study market maturity. The addition of a capacity mechanism in a market architecture with price cap is compared to scarcity pricing in different situations. Simulations are performed for two different cases: a case without any exogenous closure of existing power plants and a case with exogenous retirements which create a need of new investments. Under the assumption of a risk-neutral investor, the results indicate that compared to an energy-only market with price cap set at euro 3,000/MWh, energy-only with scarcity pricing and capacity mechanism are two efficient market designs to reach an acceptable level of loss of load. Besides, the results highlight that the advantage of one design on the other in terms of social efficiency depends on the future scenarios which are simulated. Moreover, the results illustrates that the three market designs lead to different level of risk for peaking units, suggesting that including risk aversion is a relevant further step in the modelling. (authors)

  11. Comparative evaluation and correlation of salivary total antioxidant capacity and salivary pH in caries-free and severe early childhood caries children.

    Science.gov (United States)

    Muchandi, Sneha; Walimbe, Hrishikesh; Bijle, Mohammed Nadeem Ahmed; Nankar, Meenakshi; Chaturvedi, Srishti; Karekar, Priyanka

    2015-03-01

    Dental caries is a major problem in preschool children. The contribution of saliva in providing defense during caries process is of primary importance. pH buffer capacity through bicarbonate, phosphate and protein buffer systems have universal acceptance as a caries defense mechanism. Antioxidant capacity of saliva can constitute a first line of defense against chronic degenerative diseases including dental caries. Till date, no study is presented with salivary antioxidant capacity of younger children affected with severe early childhood caries with its salivary pH correlation. Hence, this study was carried out to compare, evaluate and correlate the salivary total antioxidant capacity (TAC) and salivary pH of children with caries-free and severe early childhood caries. Fifty children from ages 3 to 5 years divided into two study groups had undergone screening. Group I (n = 25) with severe early childhood caries (S-ECC) and group II (n = 25) who were caries free. Unstimulated whole saliva of subjects were in the collection during the study by draining method. Salivary pH determination of saliva samples was done using pH indicator paper strips. The TAC was done using an antioxidant assay with the help of a spectrophotometer at wavelength 532 nm. The means of salivary pH and TAC were subjected to analysis using unpaired student 't' test and correlation was determined using Pearsons correlation coefficient analysis. Mean salivary pH was higher in group II (7.46 ± 0.37). Mean TAC was greater in group I (1.82 ± 0.19). A statistically significant negative correlation as seen between TAC and salivary pH in S-ECC patients. The study concludes that salivary TAC increases in patients with S-ECC are by that showing a high indirect relationship with salivary pH.

  12. Malaria prevalence defined by microscopy, antigen detection, DNA amplification and total nucleic acid amplification in a malaria-endemic region during the peak malaria transmission season.

    Science.gov (United States)

    Waitumbi, John N; Gerlach, Jay; Afonina, Irina; Anyona, Samuel B; Koros, Joseph N; Siangla, Joram; Ankoudinova, Irina; Singhal, Mitra; Watts, Kate; Polhemus, Mark E; Vermeulen, Nicolaas M; Mahoney, Walt; Steele, Matt; Domingo, Gonzalo J

    2011-07-01

    To determine the malaria prevalence by microscopy, antigen detection and nucleic acid detection in a defined subpopulation in a Plasmodium falciparum-endemic region during the peak transmission season. Blood specimens were collected in a cross-sectional study involving children aged 5-10 years (n = 195) presenting with acute fever to two clinics in Western Kenya. All specimens underwent microscopy, HRP2 and aldolase antigen detection by enzyme immunoassay (EIA), parasite-specific DNA and total nucleic acid (RNA and DNA) by real-time PCR (qPCR) and reverse-transcriptase PCR (qRT-PCR). Microscopy detected 65/195 cases of malaria infection [95% confidence interval (CI) 52-78]. HRP2 and aldolase EIA had similar sensitivity levels detecting antigen in 65/195 (95% CI, 52-78) and 57/195 (95% CI, 45-70) cases. Discordants in antigen detection vs. microscopy occurred at Detection of total nucleic acid allowed a 3 log lower limit of detection than just DNA detection by real-time PCR in vitro. In clinical specimens, 114/195 (95% CI, 100-127) were qPCR positive (DNA), and 187/195 (95% CI, 179-191) were qRT-PCR positive (DNA plus RNA). The prevalence of submicroscopic malaria infection was significantly higher when detecting total nucleic acid than just DNA in this outpatient population during the high transmission season. Defining standards for submicroscopic infection will be important for control programmes, diagnostics development efforts and molecular epidemiology studies. © 2011 Blackwell Publishing Ltd.

  13. A model of market power in electricity industries subject to peak load pricing

    International Nuclear Information System (INIS)

    Arellano, Maria-Soledad; Serra, Pablo

    2007-01-01

    This paper studies the exercise of market power in price-regulated electricity industries under peak-load pricing and merit order dispatching, but where investment decisions are taken by independent generating companies. Within this context, we show that producers can exercise market power by under-investing in base-load capacity, compared to the welfare-maximizing configuration. We also show that when there is free entry with an exogenous fixed entry cost that is later sunk, more intense competition results in higher welfare but fewer firms. (author)

  14. PolyaPeak: Detecting Transcription Factor Binding Sites from ChIP-seq Using Peak Shape Information

    Science.gov (United States)

    Wu, Hao; Ji, Hongkai

    2014-01-01

    ChIP-seq is a powerful technology for detecting genomic regions where a protein of interest interacts with DNA. ChIP-seq data for mapping transcription factor binding sites (TFBSs) have a characteristic pattern: around each binding site, sequence reads aligned to the forward and reverse strands of the reference genome form two separate peaks shifted away from each other, and the true binding site is located in between these two peaks. While it has been shown previously that the accuracy and resolution of binding site detection can be improved by modeling the pattern, efficient methods are unavailable to fully utilize that information in TFBS detection procedure. We present PolyaPeak, a new method to improve TFBS detection by incorporating the peak shape information. PolyaPeak describes peak shapes using a flexible Pólya model. The shapes are automatically learnt from the data using Minorization-Maximization (MM) algorithm, then integrated with the read count information via a hierarchical model to distinguish true binding sites from background noises. Extensive real data analyses show that PolyaPeak is capable of robustly improving TFBS detection compared with existing methods. An R package is freely available. PMID:24608116

  15. Phonon model of perovskite thermal capacity

    International Nuclear Information System (INIS)

    Kesler, Ya.A.; Poloznikova, M.Eh.; Petrov, K.I.

    1983-01-01

    A model for calculating the temperature curve of thermal capacity of perovskite family crystals on the basis of vibrational spectra is proposed. Different representatives of the perovskite family: cubic SrTiO 3 , tetragonal BaTiO 3 and orthorbombic CaTiO 3 and LaCrO 3 are considered. The total frequency set is used in thermal capacity calcUlations. Comparison of the thermal capacity values of compounds calculated on the basis of the proposed model with the experimental values shows their good agreement. The method is also recommended for other compounds with the perovskite-like structure

  16. Exercise training induces similar elevations in the activity of oxoglutarate dehydrogenase and peak oxygen uptake in the human quadriceps muscle

    DEFF Research Database (Denmark)

    Blomstrand, Eva; Krustrup, Peter; Søndergaard, Hans

    2011-01-01

    During exercise involving a small muscle mass, peak oxygen uptake is thought to be limited by peripheral factors, such as the degree of oxygen extraction from the blood and/or mitochondrial oxidative capacity. Previously, the maximal activity of the Krebs cycle enzyme oxoglutarate dehydrogenase has...

  17. Capacity credit of wind power in the Netherlands

    International Nuclear Information System (INIS)

    Wijk, A.J.M. van; Turkenburg, W.C.

    1993-01-01

    The Dutch Government has stated that by the year 2000 a total amount of 1000 MW wind power should be installed in the Netherlands. The penetration of wind power into the electricity supply system poses questions about the costs and benefits of wind power. One of the parameters affecting the benefits is the amount of conventional capacity that can be saved by wind power, the so-called 'capacity credit'. In this study the capacity credit of wind power in the Netherlands is analysed. The capacity credit is calculated using a probabilistic method which evaluates the loss of load expectation (LOLE) of the total electricity generating system. In these evaluations the available wind power is treated as 'negative load'. The capacity credit is evaluated with respect to the Dutch electricity generating system and the electricity demand that is projected for the year 2000 by the Dutch utilities. Special attention is given to modelling the hourly wind power production. The model incorporates detailed siting information, wind speed data for several meteorological stations and the power curves of five different types of wind turbines. The average amount of electricity produced by wind power can be expressed by the capacity factor. For the set of assumptions and for the meteorological conditions for the years investigated the capacity factor has a value of 22%. 30 refs, 10 figs, 3 tabs

  18. Natural gas productive capacity for the lower 48 states 1984 through 1996, February 1996

    International Nuclear Information System (INIS)

    1996-01-01

    This is the fourth wellhead productive capacity report. The three previous ones were published in 1991, 1993, and 1994. This report should be of particular interest to those in Congress, Federal and State agencies, industry, and the academic community, who are concerned with the future availability of natural gas. The EIA Dallas Field Office has prepared five earlier reports regarding natural gas productive capacity. These reports, Gas Deliverability and Flow Capacity of Surveillance Fields, reported deliverability and capacity data for selected gas fields in major gas producing areas. The data in the reports were based on gas-well back-pressure tests and estimates of gas-in-place for each field or reservoir. These reports use proven well testing theory, most of which has been employed by industry since 1936 when the Bureau of Mines first published Monograph 7. Demand for natural gas in the United States is met by a combination of natural gas production, underground gas storage, imported gas, and supplemental gaseous fuels. Natural gas production requirements in the lower 48 States have been increasing during the last few years while drilling has remained at low levels. This has raised some concern about the adequacy of future gas supplies, especially in periods of peak heating or cooling demand. The purpose of this report is to address these concerns by presenting a 3-year projection of the total productive capacity of natural gas at the wellhead for the lower 48 States. Alaska is excluded because Alaskan gas does not enter the lower-48 States pipeline system. The Energy Information Administration (EIA) generates this 3-year projection based on historical gas-well drilling and production data from State, Federal, and private sources. In addition to conventional gas-well gas, coalbed gas and oil-well gas are also included

  19. Optimal Planning Method of On-load Capacity Regulating Distribution Transformers in Urban Distribution Networks after Electric Energy Replacement Considering Uncertainties

    Directory of Open Access Journals (Sweden)

    Yu Su

    2018-06-01

    Full Text Available Electric energy replacement is the umbrella term for the use of electric energy to replace oil (e.g., electric automobiles, coal (e.g., electric heating, and gas (e.g., electric cooking appliances, which increases the electrical load peak, causing greater valley/peak differences. On-load capacity regulating distribution transformers have been used to deal with loads with great valley/peak differences, so reasonably replacing conventional distribution transformers with on-load capacity regulating distribution transformers can effectively cope with load changes after electric energy replacement and reduce the no-load losses of distribution transformers. Before planning for on-load capacity regulating distribution transformers, the nodal effective load considering uncertainties within the life cycle after electric energy replacement was obtained by a Monte Carlo method. Then, according to the loss relation between on-load capacity regulating distribution transformers and conventional distribution transformers, three characteristic indexes of annual continuous apparent power curve and replacement criteria for on-load capacity regulating distribution transformers were put forward in this paper, and a set of distribution transformer replaceable points was obtained. Next, based on cost benefit analysis, a planning model of on-load capacity regulating distribution transformers which consists of investment profitability index within the life cycle, investment cost recouping index and capacity regulating cost index was put forward. The branch and bound method was used to solve the planning model within replaceable point set to obtain upgrading and reconstruction scheme of distribution transformers under a certain investment. Finally, planning analysis of on-load capacity regulating distribution transformers was carried out for electric energy replacement points in one urban distribution network under three scenes: certain load, uncertain load and nodal

  20. Evaluating the Cost of Line Capacity Limitations in Aggregations of Commercial Buildings

    DEFF Research Database (Denmark)

    Ziras, Charalampos; Delikaraoglou, Stefanos; Kazempour, Jalal

    2017-01-01

    -ahead optimization strategy to assess the cost of imposing capacity limitations in the total consumption of individual buildings, as well as aggregations of buildings. We show that such capacity limitations lead to an increase for the buildings operational costs, which can be interpreted as the value...... of these limitations. Based on such calculations, the aggregator can value capacity-limitation services to the distribution system operator. Moreover, the value of aggregation is also highlighted, since it leads to lower costs than imposing the same total capacity limitation on individual buildings....

  1. Effect of vitamin E and C supplementation on oxidative damage and total antioxidant capacity in lead-exposed workers.

    Science.gov (United States)

    Rendón-Ramírez, Adela-Leonor; Maldonado-Vega, María; Quintanar-Escorza, Martha-Angelica; Hernández, Gerardo; Arévalo-Rivas, Bertha-Isabel; Zentella-Dehesa, Alejandro; Calderón-Salinas, José-Víctor

    2014-01-01

    The molecular response of the antioxidant system and the effects of antioxidant supplementation against oxidative insult in lead-exposed workers has not been sufficiently studied. In this work, antioxidants (vitamin E 400 IU+vitamin C 1g/daily) were supplemented for one year to 15 workers exposed to lead (73 μg of lead/dl of blood) and the results were compared with those on 19 non-lead exposed workers (6.7 μg of lead/dl). Lead intoxication was accompanied by a high oxidative damage and an increment in the erythrocyte antioxidant response due to increased activity of catalase and superoxide dismutase. Antioxidant supplementations decreased significantly the oxidative damage as well as the total antioxidant capacity induced by lead intoxication with reduction of the antioxidant enzyme activities. We conclude that antioxidant supplementation is effective in reducing oxidative damage and induces modifications in the physiopathological status of the antioxidant response in lead-exposed workers. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Capacity payment impact on gas-fired generation investments under rising renewable feed-in — A real options analysis

    International Nuclear Information System (INIS)

    Hach, Daniel; Spinler, Stefan

    2016-01-01

    We assess the effect of capacity payments on investments in gas-fired power plants in the presence of different degrees of renewable energy technology (RET) penetration. Low variable cost renewables increasingly make investments in gas-fired generation unprofitable. At the same time, growing feed-in from intermittent RETs amplifies fluctuations in power generation, thus entailing the need for flexible buffer capacity—currently mostly gas-fired power plants. A real options approach is applied to evaluate investment decisions and timing of a single investor in gas-fired power generation. We investigate the necessity and effectiveness of capacity payments. Our model incorporates multiple uncertainties and assesses the effect of capacity payments under different degrees of RET penetration. In a numerical study, we implement stochastic processes for peak-load electricity prices and natural gas prices. We find that capacity payments are an effective measure to promote new gas-fired generation projects. Especially in times of high renewable feed-in, capacity payments are required to incentivize peak-load investments. - Highlights: • We assess capacity payments under the specific focus of the influence of different degrees of renewable feed-in. • We use a real options approach to analyze investment decision and timing. • Our model reflects stochastic gas prices and stochastic electricity prices. • The case study shows the value of capacity payments to investors especially under high renewable feed-in.

  3. Red wine intake but not other alcoholic beverages increases total antioxidant capacity and improves pro-inflammatory profile after an oral fat diet in healthy volunteers.

    Science.gov (United States)

    Torres, A; Cachofeiro, V; Millán, J; Lahera, V; Nieto, M L; Martín, R; Bello, E; Alvarez-Sala, L A

    2015-12-01

    Different alcoholic beverages exert different effects on inflammation and oxidative stress but these results are controversial and scanty in some aspects. We analyze the effect of different alcoholic beverages after a fat-enriched diet on lipid profile, inflammatory factors and oxidative stress in healthy people in a controlled environment. We have performed a cross-over design in five different weeks. Sixteen healthy volunteers have received the same oral fat-enriched diet (1486kcal/m(2)) and a daily total amount of 16g/m(2) of alcohol, of different beverages (red wine, vodka, brandy or rum) and equivalent caloric intakes as sugar with water in the control group. We have measured the levels of serum lipids, high sensitivity C-reactive protein (hsCRP), tumor necrosis factor α (TNFα), interleukin 6 (IL-6), soluble phospholipase A2 (sPLA2), lipid peroxidation (LPO) and total antioxidant capacity (TAC). Red wine intake was associated with decreased of mean concentrations of hsCRP, TNFα and IL-6 induced by fat-enriched diet (p<0.05); nevertheless, sPLA2 concentrations were not significantly modified. After a fat-enriched diet added with red wine, TAC increased as compared to the same diet supplemented with rum, brandy, vodka or the control (water with sugar) (p<0.05). Moderate red wine intake, but not other alcoholic beverages, decreased pro-inflammatory factors and increased total antioxidant capacity despite a fat-enriched diet intake in healthy young volunteers. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Medicina Interna (SEMI). All rights reserved.

  4. Managing Recurrent Congestion of Subway Network in Peak Hours with Station Inflow Control

    Directory of Open Access Journals (Sweden)

    Qingru Zou

    2018-01-01

    Full Text Available Station inflow control (SIC is an important and effective method for reducing recurrent congestion during peak hours in the Beijing, Shanghai, and Guangzhou subway systems. This work proposes a practical and efficient method for establishing a static SIC scheme in normal weekdays for large-scale subway networks. First, a traffic assignment model without capacity constraint is utilized to determine passenger flow distributions on the network. An internal relationship between station inflows and section flows is then constructed. Second, capacity bottlenecks are identified by considering the transport capacity of each section. Then, a feedback-based bottleneck elimination strategy is established to search target control stations and determine their control time and control strength. To validate the effectiveness of the proposed approach, a decision support system coded in the C# programming language was developed, and the Beijing subway was used as a case study. The results indicate that the proposed method and tool are capable of practical applications, and the generated SIC plan has better performance over the existing SIC plan. This study provides a practical and useful method for operation agencies to construct SIC schemes in the subway system.

  5. A Fiber Bragg Grating Interrogation System with Self-Adaption Threshold Peak Detection Algorithm.

    Science.gov (United States)

    Zhang, Weifang; Li, Yingwu; Jin, Bo; Ren, Feifei; Wang, Hongxun; Dai, Wei

    2018-04-08

    A Fiber Bragg Grating (FBG) interrogation system with a self-adaption threshold peak detection algorithm is proposed and experimentally demonstrated in this study. This system is composed of a field programmable gate array (FPGA) and advanced RISC machine (ARM) platform, tunable Fabry-Perot (F-P) filter and optical switch. To improve system resolution, the F-P filter was employed. As this filter is non-linear, this causes the shifting of central wavelengths with the deviation compensated by the parts of the circuit. Time-division multiplexing (TDM) of FBG sensors is achieved by an optical switch, with the system able to realize the combination of 256 FBG sensors. The wavelength scanning speed of 800 Hz can be achieved by a FPGA+ARM platform. In addition, a peak detection algorithm based on a self-adaption threshold is designed and the peak recognition rate is 100%. Experiments with different temperatures were conducted to demonstrate the effectiveness of the system. Four FBG sensors were examined in the thermal chamber without stress. When the temperature changed from 0 °C to 100 °C, the degree of linearity between central wavelengths and temperature was about 0.999 with the temperature sensitivity being 10 pm/°C. The static interrogation precision was able to reach 0.5 pm. Through the comparison of different peak detection algorithms and interrogation approaches, the system was verified to have an optimum comprehensive performance in terms of precision, capacity and speed.

  6. A Fiber Bragg Grating Interrogation System with Self-Adaption Threshold Peak Detection Algorithm

    Directory of Open Access Journals (Sweden)

    Weifang Zhang

    2018-04-01

    Full Text Available A Fiber Bragg Grating (FBG interrogation system with a self-adaption threshold peak detection algorithm is proposed and experimentally demonstrated in this study. This system is composed of a field programmable gate array (FPGA and advanced RISC machine (ARM platform, tunable Fabry–Perot (F–P filter and optical switch. To improve system resolution, the F–P filter was employed. As this filter is non-linear, this causes the shifting of central wavelengths with the deviation compensated by the parts of the circuit. Time-division multiplexing (TDM of FBG sensors is achieved by an optical switch, with the system able to realize the combination of 256 FBG sensors. The wavelength scanning speed of 800 Hz can be achieved by a FPGA+ARM platform. In addition, a peak detection algorithm based on a self-adaption threshold is designed and the peak recognition rate is 100%. Experiments with different temperatures were conducted to demonstrate the effectiveness of the system. Four FBG sensors were examined in the thermal chamber without stress. When the temperature changed from 0 °C to 100 °C, the degree of linearity between central wavelengths and temperature was about 0.999 with the temperature sensitivity being 10 pm/°C. The static interrogation precision was able to reach 0.5 pm. Through the comparison of different peak detection algorithms and interrogation approaches, the system was verified to have an optimum comprehensive performance in terms of precision, capacity and speed.

  7. Electricity capacity expansion in a Cournot duopoly

    DEFF Research Database (Denmark)

    Brondbo, Helene K.; Storebo, Axel; Fleten, Stein Erik

    2017-01-01

    This paper adopts a real options approach to analyze marginal investments in power markets with heterogeneous technologies and time-varying demand. We compare the investment behavior of two firms in a Cournot duopoly to a central planner's when two categories of power plants are available; base a...... that this results in welfare losses above 10 %, and significantly larger reduction in the consumer surplus. Further, we examine the effect of analyzing power markets without time-varying demand and find that this underestimates investments in peak load capacity....

  8. Standalone Photovoltaic System Sizing using Peak Sun Hour Method and Evaluation by TRNSYS Simulation

    OpenAIRE

    Riza, Dimas Firmanda Al; Gilani, Syed Ihtshamul-Haq

    2016-01-01

    This paper presents sizing and evaluation of a standalone photovoltaic system for residential load. Peak Sun Hour method is used to determine photovoltaic panel and battery capacity, then the sizing results is tested and evaluated using hourly time-step transient simulation model by using TRNSYS 16.0. The results shows for typical Malaysian terraced house that have about 6 kWh daily electricity load, the photovoltaic system requirement consist of 1.9 kWp photovoltaic panel and 2200 Ah battery...

  9. Free-Space Optical Communications: Capacity Bounds, Approximations, and a New Sphere-Packing Perspective

    KAUST Repository

    Chaaban, Anas

    2015-04-01

    The capacity of the intensity-modulation direct-detection (IM-DD) free-space optical channel is studied. It is shown that for an IM-DD channel with generally input-dependent noise, the worst noise at high SNR is input-independent Gaussian with variance dependent on the input cost. Based on this result, a Gaussian IM-DD channel model is proposed where the noise variance depends on the optical intensity constraints only. A new recursive approach for bounding the capacity of the channel based on sphere-packing is proposed, which leads to a tighter bound than an existing sphere-packing bound for the channel with only an average intensity constraint. Under both average and peak constraints, it yields bounds that characterize the high SNR capacity within a negligible gap, where the achievability is proved by using a truncated Gaussian input distribution. This completes the high SNR capacity characterization of the channel, by closing the gap in the existing characterization for a small average-to-peak ratio. Simple fitting functions that capture the best known achievable rate for the channel are provided. These functions can be of significant practical importance especially for the study of systems operating under atmospheric turbulence and misalignment conditions. Finally, the capacity/SNR loss between heterodyne detection (HD) systems and IM-DD systems is bounded at high SNR, where it is shown that the loss grows as SNR increases for a complex-valued HD system, while it is bounded by 1.245 bits or 3.76 dB at most for a real-valued one.

  10. Free-Space Optical Communications: Capacity Bounds, Approximations, and a New Sphere-Packing Perspective

    KAUST Repository

    Chaaban, Anas; Morvan, Jean-Marie; Alouini, Mohamed-Slim

    2015-01-01

    The capacity of the intensity-modulation direct-detection (IM-DD) free-space optical channel is studied. It is shown that for an IM-DD channel with generally input-dependent noise, the worst noise at high SNR is input-independent Gaussian with variance dependent on the input cost. Based on this result, a Gaussian IM-DD channel model is proposed where the noise variance depends on the optical intensity constraints only. A new recursive approach for bounding the capacity of the channel based on sphere-packing is proposed, which leads to a tighter bound than an existing sphere-packing bound for the channel with only an average intensity constraint. Under both average and peak constraints, it yields bounds that characterize the high SNR capacity within a negligible gap, where the achievability is proved by using a truncated Gaussian input distribution. This completes the high SNR capacity characterization of the channel, by closing the gap in the existing characterization for a small average-to-peak ratio. Simple fitting functions that capture the best known achievable rate for the channel are provided. These functions can be of significant practical importance especially for the study of systems operating under atmospheric turbulence and misalignment conditions. Finally, the capacity/SNR loss between heterodyne detection (HD) systems and IM-DD systems is bounded at high SNR, where it is shown that the loss grows as SNR increases for a complex-valued HD system, while it is bounded by 1.245 bits or 3.76 dB at most for a real-valued one.

  11. Comparison of isokinetic peak force and power in adults with partial and total blindness.

    Science.gov (United States)

    Horvat, Michael; Ray, Christopher; Nocera, Joe; Croce, Ron

    2006-08-01

    For many populations the ability to move efficiently is compromised by an impaired muscular functioning. Strength development is necessary to overcome the effects of gravity to maintain posture and generate movement responses for mobility. The strength and power capabilities of individuals with total blindness (n = 12) were compared to those with partial vision (n = 12) to evaluate effects of vision on performance. Results indicate that (1) no significant differences were apparent between total blindness and partial vision, (2) significant sex differences were evident in each group, and (3) better performance was apparent at lower velocities. It was concluded that physical performance in individuals with blindness and partial vision are equally deficient.

  12. Research on Overconfidence in Decision-Making for the Capacity Recovery of Damaged Power Systems

    Directory of Open Access Journals (Sweden)

    Xing Bao

    2014-01-01

    Full Text Available This paper studies the influence of two types of overconfident behavior, overestimation and overprecision, on decision of capacity recovery when power system’s critical capacity is seriously damaged. A newsvendor model is used to prove that increasing regulatory punishment for electricity shortage and providing subsidy for capacity recovery are conducive measures to calibrate insufficient service level caused by an overconfident manager. The research also finds that the manager’s overprecision behavior both negatively and positively influences the decision of capacity recovery, and a calibration method could motivate manager to recover more capacity by tuning up the ratio of punishment and subsidy. However, the effectiveness of the calibration mentioned above is inevitably weakened due to the less capacity recovery given by an overestimated manager. This research also indicates that the manager should pay close attention to the random disturbance whose distribution peak is left skewed, and correspondingly more capacity recovery should be given to improve the service level of power system during the disruption.

  13. Mean and peak wind load reduction on heliostats

    Energy Technology Data Exchange (ETDEWEB)

    Peterka, J.A.; Tan, L.; Bienkiewcz, B.; Cermak, J.E.

    1987-09-01

    This report presents the results of wind-tunnel tests supported through the Solar Energy Research Institute (SERI) by the Office of Solar Thermal Technology of the US Department of Energy as part of the SERI research effort on innovative concentrators. As gravity loads on drive mechanisms are reduced through stretched-membrane technology, the wind-load contribution of the required drive capacity increases in percentage. Reduction of wind loads can provide economy in support structure and heliostat drive. Wind-tunnel tests have been directed at finding methods to reduce wind loads on heliostats. The tests investigated both mean and peak forces, and moments. A significant increase in ability to predict heliostat wind loads and their reduction within a heliostat field was achieved. In addition, a preliminary review of wind loads on parabolic dish collectors was conducted, resulting in a recommended research program for these type collectors. 42 refs., 38 figs., 1 tab.

  14. Peak power reduction and energy efficiency improvement with the superconducting flywheel energy storage in electric railway system

    Science.gov (United States)

    Lee, Hansang; Jung, Seungmin; Cho, Yoonsung; Yoon, Donghee; Jang, Gilsoo

    2013-11-01

    This paper proposes an application of the 100 kWh superconducting flywheel energy storage systems to reduce the peak power of the electric railway system. The electric railway systems have high-power characteristics and large amount of regenerative energy during vehicles’ braking. The high-power characteristic makes operating cost high as the system should guarantee the secure capacity of electrical equipment and the low utilization rate of regenerative energy limits the significant energy efficiency improvement. In this paper, it had been proved that the peak power reduction and energy efficiency improvement can be achieved by using 100 kWh superconducting flywheel energy storage systems with the optimally controlled charging or discharging operations. Also, economic benefits had been assessed.

  15. Total water production capacity inversion phenomenon in multi-stage direct contact membrane distillation: A theoretical study

    KAUST Repository

    Lee, Jung Gil

    2017-09-09

    The low thermal efficiency and low water production are among the major challenges that prevent membrane distillation (MD) process from being commercialized. In an effort to design an efficient multi-stage direct contact MD (DCMD) unit through mathematical simulation, a new phenomenon that we refer to as total water production capacity inversion (WPI) has been detected. It is represented by a decrease in the total water production beyond a number of stages or a certain module length. WPI phenomenon, which was confirmed by using two different mathematical models validated experimentally, was found to take place due to the decrease in water vapor flux across the membrane as well as the increase in heat loss by conduction as the membrane length increases. Therefore, WPI should be considered as a critical MD design-criterion, especially for large scale units. Investigations conducted for a simulated multi-stage DCMD process showed that inlet feed and permeate temperatures difference, feed and permeate flow rates, and feed salinity have different effects on WPI. The number of stages (or module length at constant width) that leads to a maximum water production has been determined for different operating parameters. Decreasing inlet feed and permeate temperatures difference, or inlet feed and permeate flow rates and increasing inlet feed temperature at constant temperature difference or inlet feed salinity cause the WPI to take place at lower number of stages. Even though the feed salinity affects negligibly the mean permeate flux, it was clearly shown that it can affect WPI. The results presented herein unveil a hidden phenomenon that is likely to occur during process scale-up procedures and should be considered by process engineers for a proper choice of system design and operating conditions.

  16. Measurements and simulations for peak electrical load reduction in cooling dominated climate

    International Nuclear Information System (INIS)

    Sadineni, Suresh B.; Boehm, Robert F.

    2012-01-01

    Peak electric demand due to cooling load in the Desert Southwest region of the US has been an issue for the electrical energy suppliers. To address this issue, a consortium has been formed between the University of Nevada Las Vegas, Pulte Homes (home builder) and NV Energy (local utility) in order to reduce the peak load by more than 65%. The implemented strategies that were used to accomplish that goal consist of energy efficiency in homes, onsite electricity generation through roof integrated PV, direct load control, and battery storage at the substation level. The simulation models developed using building energy analysis software were validated against measured data. The electrical energy demand for the upgraded home during peak period (1:00–7:00 PM) decreased by approximately 37% and 9% compared to a code standard home of the same size, due to energy efficiency and PV generation, respectively. The total decrease in electrical demand due to energy efficiency and PV generation during the peak period is 46%. Additionally, a 2.2 °C increase in thermostat temperature from 23.9 °C to 26.1 °C between 4:00 PM and 7:00 PM has further decreased the average demand during the peak period by 69% of demand from a standard home. -- Highlights: ► A study to demonstrate peak load reductions of 65% at the substation. ► A new residential energy efficient community named Villa Trieste is being developed. ► The peak demand from the homes has decreased by 37% through energy efficiency. ► A 1.8 kWp system along with energy efficiency measures decreased peak by 46%.

  17. Peak-by-peak correction of Ge(Li) gamma-ray spectra for photopeaks from background

    Energy Technology Data Exchange (ETDEWEB)

    Cutshall, N H; Larsen, I L [Oak Ridge National Lab., TN (USA)

    1980-12-01

    Background photopeaks can interfere with accurate measurement of low levels of radionuclides by gamma-ray spectrometry. A flowchart for peak-by-peak correction of sample spectra to produce accurate results is presented.

  18. Attenuated Increase in Maximal Force of Rat Medial Gastrocnemius Muscle after Concurrent Peak Power and Endurance Training

    Directory of Open Access Journals (Sweden)

    Regula Furrer

    2013-01-01

    Full Text Available Improvement of muscle peak power and oxidative capacity are generally presumed to be mutually exclusive. However, this may not be valid by using fibre type-specific recruitment. Since rat medial gastrocnemius muscle (GM is composed of high and low oxidative compartments which are recruited task specifically, we hypothesised that the adaptive responses to peak power training were unaffected by additional endurance training. Thirty rats were subjected to either no training (control, peak power training (PT, or both peak power and endurance training (PET, which was performed on a treadmill 5 days per week for 6 weeks. Maximal running velocity increased 13.5% throughout the training and was similar in both training groups. Only after PT, GM maximal force was 10% higher than that of the control group. In the low oxidative compartment, mRNA levels of myostatin and MuRF-1 were higher after PT as compared to those of control and PET groups, respectively. Phospho-S6 ribosomal protein levels remained unchanged, suggesting that the elevated myostatin levels after PT did not inhibit mTOR signalling. In conclusion, even by using task-specific recruitment of the compartmentalized rat GM, additional endurance training interfered with the adaptive response of peak power training and attenuated the increase in maximal force after power training.

  19. Coupling hydrologic and hydraulic models to take into consideration retention effects on extreme peak discharges in Switzerland

    Science.gov (United States)

    Felder, Guido; Zischg, Andreas; Weingartner, Rolf

    2015-04-01

    Estimating peak discharges with very low probabilities is still accompanied by large uncertainties. Common estimation methods are usually based on extreme value statistics applied to observed time series or to hydrological model outputs. However, such methods assume the system to be stationary and do not specifically consider non-stationary effects. Observed time series may exclude events where peak discharge is damped by retention effects, as this process does not occur until specific thresholds, possibly beyond those of the highest measured event, are exceeded. Hydrological models can be complemented and parameterized with non-linear functions. However, in such cases calibration depends on observed data and non-stationary behaviour is not deterministically calculated. Our study discusses the option of considering retention effects on extreme peak discharges by coupling hydrological and hydraulic models. This possibility is tested by forcing the semi-distributed deterministic hydrological model PREVAH with randomly generated, physically plausible extreme precipitation patterns. The resulting hydrographs are then used to force the hydraulic model BASEMENT-ETH (riverbed in 1D, potential inundation areas in 2D). The procedure ensures that the estimated extreme peak discharge does not exceed the physical limit given by the riverbed capacity and that the dampening effect of inundation processes on peak discharge is considered.

  20. Peaking-factor of PWR

    International Nuclear Information System (INIS)

    Morioka, Noboru; Kato, Yasuji; Yokoi, M.

    1975-01-01

    Output peaking factor often plays an important role in the safety and operation of nuclear reactors. The meaning of the peaking factor of PWRs is categorized into two features or the peaking factor in core (FQ-core) and the peaking factor on the basis of accident analysis (or FQ-limit). FQ-core is the actual peaking factor realized in nuclear core at the time of normal operation, and FQ-limit should be evaluated from loss of coolant accident and other abnormal conditions. If FQ-core is lower than FQ-limit, the reactor may be operated at full load, but if FQ-core is larger than FQ-limit, reactor output should be controlled lower than FQ-limit. FQ-core has two kinds of values, or the one on the basis of nuclear design, and the other actually measured in reactor operation. The first FQ-core should be named as FQ-core-design and the latter as FQ-core-measured. The numerical evaluation of FQ-core-design is as follows; FQ-core-design of three-dimensions is synthesized with FQ-core horizontal value (X-Y) and FQ-core vertical value, the former one is calculated with ASSY-CORE code, and the latter one with one dimensional diffusion code. For the evaluation of FQ-core-measured, on-site data observation from nuclear reactor instrumentation or off-site data observation is used. (Iwase, T.)

  1. Energy-Efficiency Analysis of Per-Subcarrier Antenna Selection with Peak-Power Reduction in MIMO-OFDM Wireless Systems

    Directory of Open Access Journals (Sweden)

    Ngoc Phuc Le

    2014-01-01

    Full Text Available The use of per-subcarrier antenna subset selection in OFDM wireless systems offers higher system capacity and/or improved link reliability. However, the implementation of the conventional per-subcarrier selection scheme may result in significant fluctuations of the average power and peak power across antennas, which affects the potential benefits of the system. In this paper, power efficiency of high-power amplifiers and energy efficiency in per-subcarrier antenna selection MIMO-OFDM systems are investigated. To deliver the maximum overall power efficiency, we propose a two-step strategy for data-subcarrier allocation. This strategy consists of an equal allocation of data subcarriers based on linear optimization and peak-power reduction via cross-antenna permutations. For analysis, we derive the CCDF (complementary cumulative distribution function of the power efficiency as well as the analytical expressions of the average power efficiency. It is proved from the power-efficiency perspective that the proposed allocation scheme outperforms the conventional scheme. We also show that the improvement in the power efficiency translates into an improved capacity and, in turn, increases energy efficiency of the proposed system. Simulation results are provided to validate our analyses.

  2. Uncertainty of the peak flow reconstruction of the 1907 flood in the Ebro River in Xerta (NE Iberian Peninsula)

    Science.gov (United States)

    Ruiz-Bellet, Josep Lluís; Castelltort, Xavier; Balasch, J. Carles; Tuset, Jordi

    2017-02-01

    There is no clear, unified and accepted method to estimate the uncertainty of hydraulic modelling results. In historical floods reconstruction, due to the lower precision of input data, the magnitude of this uncertainty could reach a high value. With the objectives of giving an estimate of the peak flow error of a typical historical flood reconstruction with the model HEC-RAS and of providing a quick, simple uncertainty assessment that an end user could easily apply, the uncertainty of the reconstructed peak flow of a major flood in the Ebro River (NE Iberian Peninsula) was calculated with a set of local sensitivity analyses on six input variables. The peak flow total error was estimated at ±31% and water height was found to be the most influential variable on peak flow, followed by Manning's n. However, the latter, due to its large uncertainty, was the greatest contributor to peak flow total error. Besides, the HEC-RAS resulting peak flow was compared to the ones obtained with the 2D model Iber and with Manning's equation; all three methods gave similar peak flows. Manning's equation gave almost the same result than HEC-RAS. The main conclusion is that, to ensure the lowest peak flow error, the reliability and precision of the flood mark should be thoroughly assessed.

  3. Peak-by-peak correction of Ge(Li) gamma-ray spectra for photopeaks from background

    International Nuclear Information System (INIS)

    Cutshall, N.H.; Larsen, I.L.

    1980-01-01

    Background photopeaks can interfere with accurate measurement of low levels of radionuclides by gamma-ray spectrometry. A flowchart for peak-by-peak correction of sample spectra to produce accurate results is presented. (orig.)

  4. The Benefits of Exercise Training on Aerobic Capacity in Patients with Heart Failure and Preserved Ejection Fraction.

    Science.gov (United States)

    do Prado, Danilo Marcelo Leite; Rocco, Enéas Antônio

    2017-01-01

    Heart failure with preserved ejection fraction (HFpEF) is defined as an inability of the ventricles to optimally accept blood from atria with blunted end- diastolic volume response by limiting the stroke volume and cardiac output. The HEpEF prevalence is higher in elderly and women and may be associated to hypertension, diabetes mellitus and atrial fibrillation. Severe exercise intolerance, manifested by dyspnea and fatigue during physical effort is the important chronic symptom in HFpEF patients, in which is the major determinant of their reduced quality of life. In this sense, several studies demonstrated reduced aerobic capacity in terms of lower peak oxygen consumption (peak VO 2 ) in patients with HFpEF. In addition, the lower aerobic capacity observed in HFpEF may be due to impaired both convective and diffusive O 2 transport (i.e. reduced cardiac output and arteriovenous oxygen difference, respectively).Exercise training program can help restore physiological function in order to increase aerobic capacity and improve the quality of life in HFpEF patients. Therefore, the primary purpose of this chapter was to clarify the physiological mechanisms associated with reduced aerobic capacity in HFpEF patients. Secondly, special focus was devoted to show how aerobic exercise training can improve aerobic capacity and quality of life in HFpEF patients.

  5. Comparative evaluation of the polyphenol composition and antioxidant capacity of propolis and Echinacea purpurea

    OpenAIRE

    Silviya S. Georgieva; Valentina L. Christova-Bagdassarian; Maria S. Atanassova

    2014-01-01

    Objective: This study was undertaken to evaluate and compare total phenolics and total flavonoides, and antioxidant capacity of propolis and Echinacea purpurea ethanol extracts. Methods: Propolis and dried Echinacea purpurea extracts were obtained by extraction methods. The extracts were tested for total phenol and total flavonoid contents and antioxidant capacity was determined by the 2,2-diphenyl-1-picrylhydrazyl (DPPH) assay. Results: The content of total phenolics and total flavon...

  6. Evaluation of different time domain peak models using extreme learning machine-based peak detection for EEG signal.

    Science.gov (United States)

    Adam, Asrul; Ibrahim, Zuwairie; Mokhtar, Norrima; Shapiai, Mohd Ibrahim; Cumming, Paul; Mubin, Marizan

    2016-01-01

    Various peak models have been introduced to detect and analyze peaks in the time domain analysis of electroencephalogram (EEG) signals. In general, peak model in the time domain analysis consists of a set of signal parameters, such as amplitude, width, and slope. Models including those proposed by Dumpala, Acir, Liu, and Dingle are routinely used to detect peaks in EEG signals acquired in clinical studies of epilepsy or eye blink. The optimal peak model is the most reliable peak detection performance in a particular application. A fair measure of performance of different models requires a common and unbiased platform. In this study, we evaluate the performance of the four different peak models using the extreme learning machine (ELM)-based peak detection algorithm. We found that the Dingle model gave the best performance, with 72 % accuracy in the analysis of real EEG data. Statistical analysis conferred that the Dingle model afforded significantly better mean testing accuracy than did the Acir and Liu models, which were in the range 37-52 %. Meanwhile, the Dingle model has no significant difference compared to Dumpala model.

  7. Protein Binding Capacity of Different Forages Tannin

    Science.gov (United States)

    Yusiati, L. M.; Kurniawati, A.; Hanim, C.; Anas, M. A.

    2018-02-01

    Eight forages of tannin sources(Leucaena leucocephala, Arachis hypogaea, Mimosa pudica, Morus alba L, Swietenia mahagoni, Manihot esculenta, Gliricidia sepium, and Bauhinia purpurea)were evaluated their tannin content and protein binding capacity. The protein binding capacity of tannin were determined using precipitation of bovine serum albumin (BSA). Swietenia mahagonihas higest total tannin level and condensed tannin (CT) compared with other forages (P<0.01). The Leucaena leucocephala has highest hydrolysable tannin (HT) level (P<0.01). The total and condensed tannin content of Swietenia mahagoni were 11.928±0.04 mg/100 mg and 9.241±0.02mg/100mg dry matter (DM) of leaves. The hydrolysable tannin content of Leucaena leucocephala was 5.338±0.03 mg/100 mg DM of leaves. Binding capacity was highest in Swietenia mahagoni and Leucaena leucocephala compared to the other forages (P<0.01). The optimum binding of BSA to tannin in Leucaena leucocephala and Swietenia mahagoniwere1.181±0.44 and 1.217±0.60mg/mg dry matter of leaves. The present study reports that Swietenia mahagoni has highest of tannin content and Leucaena leucocephala and Swietenia mahagoni capacity of protein binding.

  8. WORKING MEMORY CAPACITY TEST REVEALS SUBJECTS DIFFICULTIES MANAGING LIMITED CAPACITY

    Directory of Open Access Journals (Sweden)

    R V Ershova

    2016-12-01

    Full Text Available Free recall consists of two separate stages: the emptying of working memory and reactivation [5]. The Tarnow Unchunkable Test (TUT, [7] uses double integer items to separate out only the first stage by making it difficult to reactivate items due to the lack of intra-item relationships.193 Russian college students were tested via the internet version of the TUT. The average number of items remembered in the 3 item test was 2.54 items. In the 4 item test, the average number of items decreased to 2.38. This, and a number of other qualitative distribution differences between the 3 and 4 item tests, indicate that the average capacity limit of working memory has been reached at 3 items. This provides the first direct measurement of the unchunkable capacity limit of number items.Difficulties in managing working memory occurred as most subjects remembered less as the number of items increased beyond capacity and failed to remember a single item in at least one out of three 4 item trials. The Pearson correlation between the total recall of 3 and 4 items was a small 38%.

  9. Multiscale peak detection in wavelet space.

    Science.gov (United States)

    Zhang, Zhi-Min; Tong, Xia; Peng, Ying; Ma, Pan; Zhang, Ming-Jin; Lu, Hong-Mei; Chen, Xiao-Qing; Liang, Yi-Zeng

    2015-12-07

    Accurate peak detection is essential for analyzing high-throughput datasets generated by analytical instruments. Derivatives with noise reduction and matched filtration are frequently used, but they are sensitive to baseline variations, random noise and deviations in the peak shape. A continuous wavelet transform (CWT)-based method is more practical and popular in this situation, which can increase the accuracy and reliability by identifying peaks across scales in wavelet space and implicitly removing noise as well as the baseline. However, its computational load is relatively high and the estimated features of peaks may not be accurate in the case of peaks that are overlapping, dense or weak. In this study, we present multi-scale peak detection (MSPD) by taking full advantage of additional information in wavelet space including ridges, valleys, and zero-crossings. It can achieve a high accuracy by thresholding each detected peak with the maximum of its ridge. It has been comprehensively evaluated with MALDI-TOF spectra in proteomics, the CAMDA 2006 SELDI dataset as well as the Romanian database of Raman spectra, which is particularly suitable for detecting peaks in high-throughput analytical signals. Receiver operating characteristic (ROC) curves show that MSPD can detect more true peaks while keeping the false discovery rate lower than MassSpecWavelet and MALDIquant methods. Superior results in Raman spectra suggest that MSPD seems to be a more universal method for peak detection. MSPD has been designed and implemented efficiently in Python and Cython. It is available as an open source package at .

  10. In vivo dissolution measurement with indium-111 summation peak ratios

    International Nuclear Information System (INIS)

    Jay, M.; Woodward, M.A.; Brouwer, K.R.

    1985-01-01

    Dissolution of [ 111 In]labeled tablets was measured in vivo in a totally noninvasive manner by using a modification of the perturbed angular correlation technique known as the summation peak ratio method. This method, which requires the incorporation of only 10-12 microCi into the dosage form, provided reliable dissolution data after oral administration of [ 111 In]lactose tablets. These results were supported by in vitro experiments which demonstrated that the dissolution rate as measured by the summation peak ratio method was in close agreement with the dissolution rate of salicylic acid in a [ 111 In]salicylic acid tablet. The method has the advantages of using only one detector, thereby avoiding the need for complex coincidence counting systems, requiring less radioactivity, and being potentially applicable to a gamma camera imaging system

  11. Automated asteroseismic peak detections

    DEFF Research Database (Denmark)

    de Montellano, Andres Garcia Saravia Ortiz; Hekker, S.; Themessl, N.

    2018-01-01

    Space observatories such as Kepler have provided data that can potentially revolutionize our understanding of stars. Through detailed asteroseismic analyses we are capable of determining fundamental stellar parameters and reveal the stellar internal structure with unprecedented accuracy. However......, such detailed analyses, known as peak bagging, have so far been obtained for only a small percentage of the observed stars while most of the scientific potential of the available data remains unexplored. One of the major challenges in peak bagging is identifying how many solar-like oscillation modes are visible...... of detected oscillation modes. The algorithm presented here opens the possibility for detailed and automated peak bagging of the thousands of solar-like oscillators observed by Kepler....

  12. THE BUFFER CAPACITY OF AIRWAY EPITHELIAL SECRETIONS

    Directory of Open Access Journals (Sweden)

    Dusik eKim

    2014-06-01

    Full Text Available The pH of airway epithelial secretions influences bacterial killing and mucus properties and is reduced by acidic pollutants, gastric reflux, and respiratory diseases such as cystic fibrosis (CF. The effect of acute acid loads depends on buffer capacity, however the buffering of airway secretions has not been well characterized. In this work we develop a method for titrating micro-scale (30 µl volumes and use it to study fluid secreted by the human airway epithelial cell line Calu-3, a widely used model for submucosal gland serous cells. Microtitration curves revealed that HCO3- is the major buffer. Peak buffer capacity (β increased from 17 to 28 mM/pH during forskolin stimulation, and was reduced by >50% in fluid secreted by cystic fibrosis transmembrane conductance regulator (CFTR-deficient Calu-3 monolayers, confirming an important role of CFTR in HCO3- secretion. Back-titration with NaOH revealed non-volatile buffer capacity due to proteins synthesized and released by the epithelial cells. Lysozyme and mucin concentrations were too low to buffer Calu-3 fluid significantly, however model titrations of porcine gastric mucins at concentrations near the sol-gel transition suggest that mucins may contribute to the buffer capacity of ASL in vivo. We conclude that CFTR-dependent HCO3- secretion and epithelially-derived proteins are the predominant buffers in Calu-3 secretions.

  13. Concentrations of oligomers and polymers of proanthocyanidins in red and purple rice bran and their relationships to total phenolics, flavonoids, antioxidant capacity and whole grain color.

    Science.gov (United States)

    Chen, Ming-Hsuan; McClung, Anna M; Bergman, Christine J

    2016-10-01

    Proanthocyanidins, a flavonoids subgroup, are proposed to have chronic disease modulation properties. With the eventual goal of enhancing rice phytonutrient concentrations, we investigated the genotypic variation of the concentrations of individual oligomers and polymers of proanthocyanidins in red and purple rice brans. A 4.3-fold variation in total proanthocyanidins (sum of oligomers and polymers) in the extractable fraction was found and the concentration was highly correlated with total phenolics, total flavonoids and antiradical capacity. Variation in the proportion of oligomers and polymers existed, with monomers to trimers, 4-6mers, 7-10mers and polymers accounting for 7, 18, 26.5 and 48.7%, respectively, of the total. The redness value a(∗) of whole grain rice measured in CIE L(∗)a(∗)b(∗) color space was negatively and positively correlated with extractable and non-extractable proanthocyanidins, respectively. The variation found indicates it is possible to select rice with bran containing high levels of total proanthocyanidins and specific degree of polymerization profiles. Published by Elsevier Ltd.

  14. The effects of anti-hypertensives and type 2 diabetes on salivary flow and total antioxidant capacity.

    Science.gov (United States)

    Djukić, L J; Roganović, J; Brajović, M D; Bokonjić, D; Stojić, D

    2015-07-01

    The present cross-sectional study aimed to determine the effect of first-line anti-hypertensive drugs (enalapril, metoprolol, and combinations of enalapril with metoprolol and/or hydrochlorothiazide) on salivary gland function and salivary total antioxidant capacity (TAC) in hypertensive patients with/without diabetes mellitus (DM) type 2. Salivary gland function was measured as xerostomia (interview) and unstimulated whole saliva flow rate (UWSFR) in 447 subjects (387 hypertensive and 60 healthy). Salivary TAC was evaluated by spectrophotometric assay. Enalapril is not xerogenic, while metoprolol and drug combinations are. In the presence of DM type 2, all drugs, except metoprolol, had pronounced xerogenic effect. Binary logistic regression analysis found enalapril to be significantly associated with decreased risk of xerogenic effect development, while DM type 2 with increased risk. In the presence of enalapril in hypertensive patients with/without DM type 2 salivary TAC was similar to that in healthy subjects, while for metoprolol was reduced. Enalapril is not xerogenic but is antioxidant, which moderately reduces the risk of xerogenic effect development even in the presence of DM type 2. However, metoprolol and drug combinations exhibit xerogenic effect. In DM type 2, xerogenic effect of all drugs was pronounced except of metoprolol. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Performance-based methodology for assessing seismic vulnerability and capacity of buildings

    Science.gov (United States)

    Shibin, Lin; Lili, Xie; Maosheng, Gong; Ming, Li

    2010-06-01

    This paper presents a performance-based methodology for the assessment of seismic vulnerability and capacity of buildings. The vulnerability assessment methodology is based on the HAZUS methodology and the improved capacitydemand-diagram method. The spectral displacement ( S d ) of performance points on a capacity curve is used to estimate the damage level of a building. The relationship between S d and peak ground acceleration (PGA) is established, and then a new vulnerability function is expressed in terms of PGA. Furthermore, the expected value of the seismic capacity index (SCev) is provided to estimate the seismic capacity of buildings based on the probability distribution of damage levels and the corresponding seismic capacity index. The results indicate that the proposed vulnerability methodology is able to assess seismic damage of a large number of building stock directly and quickly following an earthquake. The SCev provides an effective index to measure the seismic capacity of buildings and illustrate the relationship between the seismic capacity of buildings and seismic action. The estimated result is compared with damage surveys of the cities of Dujiangyan and Jiangyou in the M8.0 Wenchuan earthquake, revealing that the methodology is acceptable for seismic risk assessment and decision making. The primary reasons for discrepancies between the estimated results and the damage surveys are discussed.

  16. Peak power reduction and energy efficiency improvement with the superconducting flywheel energy storage in electric railway system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hansang, E-mail: hslee80@kiu.ac.kr [School of Railway and Electrical Engineering, Kyungil University, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-701 (Korea, Republic of); Jung, Seungmin [School of Electrical Engineering, Korea University, Anam-dong, Seongbuk-gu, Seoul 136-712 (Korea, Republic of); Cho, Yoonsung [Department of Electric and Energy Engineering, Catholic University of Daegu, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-702 (Korea, Republic of); Yoon, Donghee [Department of New and Renewable Energy, Kyungil University, Hayang-eup, Gyeongsangbuk-do 712-701 (Korea, Republic of); Jang, Gilsoo, E-mail: gjang@korea.ac.kr [School of Electrical Engineering, Korea University, Anam-dong, Seongbuk-gu, Seoul 136-712 (Korea, Republic of)

    2013-11-15

    Highlights: •It is important to develop power and energy management system to save operating cost. •An 100 kWh of SFES is effective to decrease peak power and energy consumption. •Operation cost saving can be achieved using superconducting flywheel energy storage. -- Abstract: This paper proposes an application of the 100 kWh superconducting flywheel energy storage systems to reduce the peak power of the electric railway system. The electric railway systems have high-power characteristics and large amount of regenerative energy during vehicles’ braking. The high-power characteristic makes operating cost high as the system should guarantee the secure capacity of electrical equipment and the low utilization rate of regenerative energy limits the significant energy efficiency improvement. In this paper, it had been proved that the peak power reduction and energy efficiency improvement can be achieved by using 100 kWh superconducting flywheel energy storage systems with the optimally controlled charging or discharging operations. Also, economic benefits had been assessed.

  17. Peak power reduction and energy efficiency improvement with the superconducting flywheel energy storage in electric railway system

    International Nuclear Information System (INIS)

    Lee, Hansang; Jung, Seungmin; Cho, Yoonsung; Yoon, Donghee; Jang, Gilsoo

    2013-01-01

    Highlights: •It is important to develop power and energy management system to save operating cost. •An 100 kWh of SFES is effective to decrease peak power and energy consumption. •Operation cost saving can be achieved using superconducting flywheel energy storage. -- Abstract: This paper proposes an application of the 100 kWh superconducting flywheel energy storage systems to reduce the peak power of the electric railway system. The electric railway systems have high-power characteristics and large amount of regenerative energy during vehicles’ braking. The high-power characteristic makes operating cost high as the system should guarantee the secure capacity of electrical equipment and the low utilization rate of regenerative energy limits the significant energy efficiency improvement. In this paper, it had been proved that the peak power reduction and energy efficiency improvement can be achieved by using 100 kWh superconducting flywheel energy storage systems with the optimally controlled charging or discharging operations. Also, economic benefits had been assessed

  18. Longitudinal relationship between wheelchair exercise capacity and life satisfaction in patients with spinal cord injury: A cohort study in the Netherlands

    Science.gov (United States)

    van Koppenhagen, Casper Floris; Post, Marcel; de Groot, Sonja; van Leeuwen, Christel; van Asbeck, Floris; Stolwijk-Swüste, Janneke; van der Woude, Lucas; Lindeman, Eline

    2014-01-01

    Objective To examine the relationship between wheelchair exercise capacity and life satisfaction in persons with spinal cord injury from the start of active inpatient rehabilitation up to 5 years after discharge. Design Prospective cohort study. Subjects Persons with spinal cord injury, aged 18–65 years, and wheelchair dependent at least for long distances. Method Measurements at the start of active rehabilitation, after 3 months, at discharge from inpatient rehabilitation, and 1 and 5 years after discharge. A peak wheelchair exercise test was performed to record peak oxygen uptake (VO2peak) and peak power output (POpeak). Life satisfaction was measured as current life satisfaction and change of life satisfaction in comparison with life after spinal cord injury. Relationships between (changes in) exercise capacity and (changes in) life satisfaction were analyzed random coefficient analysis, corrected for possible confounders (age, gender, level of lesion, functional status, secondary impairments, pain, and sports activity) if necessary. Results Of 225 persons included, 130 attended two or more peak exercise tests, who were include in the analyses. Mean age at start was 39 years, 75% were male, 73% had paraplegia, and 76% had a traumatic lesion. Mean POpeak increased during the study from 32.9 to 55.9 Watts, mean VO2peak from 1.02  to 1.38 l/minute, and mean life satisfaction from 5.7 to 7.8. An increase of POpeak with 10 W was associated with a 0.3-point increase of life satisfaction (P = 0.01). An increase of VO2peak with 0.1 l/minute was associated with a 0.1-point increase of life satisfaction (P = 0.049). Conclusion High(er) wheelchair exercise capacity is related to high(er) life satisfaction in spinal cord injury patients. PMID:24621019

  19. Longitudinal relationship between wheelchair exercise capacity and life satisfaction in patients with spinal cord injury: A cohort study in the Netherlands.

    Science.gov (United States)

    van Koppenhagen, Casper Floris; Post, Marcel; de Groot, Sonja; van Leeuwen, Christel; van Asbeck, Floris; Stolwijk-Swüste, Janneke; van der Woude, Lucas; Lindeman, Eline

    2014-05-01

    To examine the relationship between wheelchair exercise capacity and life satisfaction in persons with spinal cord injury from the start of active inpatient rehabilitation up to 5 years after discharge. Prospective cohort study. Persons with spinal cord injury, aged 18-65 years, and wheelchair dependent at least for long distances. Measurements at the start of active rehabilitation, after 3 months, at discharge from inpatient rehabilitation, and 1 and 5 years after discharge. A peak wheelchair exercise test was performed to record peak oxygen uptake (VO2peak) and peak power output (POpeak). Life satisfaction was measured as current life satisfaction and change of life satisfaction in comparison with life after spinal cord injury. Relationships between (changes in) exercise capacity and (changes in) life satisfaction were analyzed random coefficient analysis, corrected for possible confounders (age, gender, level of lesion, functional status, secondary impairments, pain, and sports activity) if necessary. Of 225 persons included, 130 attended two or more peak exercise tests, who were include in the analyses. Mean age at start was 39 years, 75% were male, 73% had paraplegia, and 76% had a traumatic lesion. Mean POpeak increased during the study from 32.9 to 55.9 Watts, mean VO2peak from 1.02 to 1.38 l/minute, and mean life satisfaction from 5.7 to 7.8. An increase of POpeak with 10 W was associated with a 0.3-point increase of life satisfaction (P = 0.01). An increase of VO2peak with 0.1 l/minute was associated with a 0.1-point increase of life satisfaction (P = 0.049). Conclusion High(er) wheelchair exercise capacity is related to high(er) life satisfaction in spinal cord injury patients.

  20. Modified Folin-Ciocalteu antioxidant capacity assay for measuring lipophilic antioxidants.

    Science.gov (United States)

    Berker, Kadriye Isil; Ozdemir Olgun, F Ayca; Ozyurt, Dilek; Demirata, Birsen; Apak, Resat

    2013-05-22

    The Folin-Ciocalteu (FC) method of performing a total phenolics assay, originally developed for protein determination, has recently evolved as a total antioxidant capacity assay but was found to be incapable of measuring lipophilic antioxidants due to the high affinity of the FC chromophore, that is, multivalent-charged phospho-tungsto-molybdate(V), toward water. Thus, the FC method was modified and standardized so as to enable simultaneous measurement of lipophilic and hydrophilic antioxidants in NaOH-added isobutanol-water medium. Optimal conditions were as follows: dilution ratio of aqueous FC reagent with iso-BuOH (1:2, v/v), final NaOH concentration of 3.5 × 10(-2) M, reaction time of 20 min, and maximum absorption wavelength of 665 nm. The modified procedure was successfully applied to the total antioxidant capacity assay of trolox, quercetin, ascorbic acid, gallic acid, catechin, caffeic acid, ferulic acid, rosmarinic acid, glutathione, and cysteine, as well as of lipophilic antioxidants such as α-tocopherol (vitamin E), butylated hydroxyanisole, butylated hydroxytoluene, tertiary butylhydroquinone, lauryl gallate, and β-carotene. The modified FC method reliably quantified ascorbic acid, whereas the conventional method could not. The modified method was reproducible and additive in terms of total antioxidant capacity values of constituents of complex mixtures such as olive oil extract and herbal tea infusion. The trolox equivalent antioxidant capacities of the tested antioxidant compounds correlated well with those found by the Cupric Reducing Antioxidant Capacity reference method.

  1. Multi-Capacity Load Cell Concept

    Directory of Open Access Journals (Sweden)

    Seif. M. OSMAN

    2014-09-01

    Full Text Available Force measuring systems are usually used to calibrate force generated systems, it is not preferable to use load cells to measure forces less than 10 % of its nominal capacity. Several load cells are required to offer calibration facilities at sites to cover different ranges, this lead to difficulties in handling procedures, through the need for several carrying cases to carry this overweight in addition to the over cost of purchasing several load cells. This article concerns with introducing a new concept for designing a multi-capacity load cell as a new force standard in the field of measuring the force. This multi-capacity load cell will replace a set of load cells and reflects economically on the total cost and on easiness of handling procedures.

  2. Peak-to-average power ratio reduction in interleaved OFDMA systems

    KAUST Repository

    Al-Shuhail, Shamael; Ali, Anum; Al-Naffouri, Tareq Y.

    2015-01-01

    Orthogonal frequency division multiple access (OFDMA) systems suffer from several impairments, and communication system engineers use powerful signal processing tools to combat these impairments and to keep up with the capacity/rate demands. One of these impairments is high peak-to-average power ratio (PAPR) and clipping is the simplest peak reduction scheme. However, in general, when multiple users are subjected to clipping, frequency domain clipping distortions spread over the spectrum of all users. This results in compromised performance and hence clipping distortions need to be mitigated at the receiver. Mitigating these distortions in multiuser case is not simple and requires complex clipping mitigation procedures at the receiver. However, it was observed that interleaved OFDMA presents a special structure that results in only self-inflicted clipping distortions (i.e., the distortions of a particular user do not interfere with other users). In this work, we prove analytically that distortions do not spread over multiple users (while utilizing interleaved carrier assignment in OFDMA) and construct a compressed sensing system that utilizes the sparsity of the clipping distortions and recovers it on each user. We provide numerical results that validate our analysis and show promising performance for the proposed clipping recovery scheme.

  3. Peak-to-average power ratio reduction in interleaved OFDMA systems

    KAUST Repository

    Al-Shuhail, Shamael

    2015-12-07

    Orthogonal frequency division multiple access (OFDMA) systems suffer from several impairments, and communication system engineers use powerful signal processing tools to combat these impairments and to keep up with the capacity/rate demands. One of these impairments is high peak-to-average power ratio (PAPR) and clipping is the simplest peak reduction scheme. However, in general, when multiple users are subjected to clipping, frequency domain clipping distortions spread over the spectrum of all users. This results in compromised performance and hence clipping distortions need to be mitigated at the receiver. Mitigating these distortions in multiuser case is not simple and requires complex clipping mitigation procedures at the receiver. However, it was observed that interleaved OFDMA presents a special structure that results in only self-inflicted clipping distortions (i.e., the distortions of a particular user do not interfere with other users). In this work, we prove analytically that distortions do not spread over multiple users (while utilizing interleaved carrier assignment in OFDMA) and construct a compressed sensing system that utilizes the sparsity of the clipping distortions and recovers it on each user. We provide numerical results that validate our analysis and show promising performance for the proposed clipping recovery scheme.

  4. Drivers of peak sales for pharmaceutical brands

    NARCIS (Netherlands)

    Fischer, Marc; Leeflang, Peter S. H.; Verhoef, Peter C.

    2010-01-01

    Peak sales are an important metric in the pharmaceutical industry. Specifically, managers are focused on the height-of-peak-sales and the time required achieving peak sales. We analyze how order of entry and quality affect the level of peak sales and the time-to-peak-sales of pharmaceutical brands.

  5. Economic competitiveness of off-peak hydrogen production today - A European comparison

    International Nuclear Information System (INIS)

    Mansilla, C.; Dautremont, S.; Louyrette, J.; Albou, S.; Bourasseau, C.

    2013-01-01

    Hydrogen has a wide range of applications. In view of the environmental benefits, hydrogen can be produced by de-carbonized means. When alkaline electrolysis is the selected process, extra value is offered by flexible operation that could bring both; an opportunity to reduce the cost of hydrogen produced (by consuming electricity during off-peak hours, and stopping the process during peak hours) and also a complementary tool to help balancing of the electric system. This paper assesses the profitability of market-driven operation for three different markets: France, Germany and Spain, with an analysis on the spot market. The market that exhibits the biggest potential in terms of profitability thanks to flexible operation is the French one, for each studied year. France is also the country that has the smallest installed renewable capacity amongst three considered countries. The gain on the hydrogen production cost allowed by the optimization is less than 3%. Hence, market-driven operation does not seem highly favourable to valorize fluctuating hydrogen production, when only the market price opportunities are considered. The balancing tool provided by the electrolysis system needs to be specifically valorized, in order to make flexible operation profitable. (authors)

  6. Physical capacity and physical strain in persons with tetraplegia; the role of sport activity

    NARCIS (Netherlands)

    Dallmeijer, A J; Hopman, M T; van As, H H; van der Woude, L H

    1996-01-01

    To determine the relationship between sport activity and physical capacity (PC) and physical strain (PS) during standardized activities of daily living (ADL), 25 subjects with tetraplegia were studied. To quantify PC, maximal power output, peak oxygen uptake and maximal isometric force were

  7. Functional exercise capacity, lung function and chest wall deformity in patients with adolescent idiopathic scoliosis

    Directory of Open Access Journals (Sweden)

    Evandro Fornias Sperandio

    Full Text Available AbstractIntroduction The adolescent idiopathic scoliosis (AIS causes changes on the compliance of the chest. These changes may be associated with impaired lung function and reduced functional exercise capacity of these adolescents. We aimed to evaluate the correlation between functional exercise capacity, lung function and geometry of the chest at different stages of AIS.Materials and methods The study was carried out in a cross-sectional design which were evaluated 27 AIS patients at different stages of the disease. For chest wall evaluation, were created geometry angles/distances (A/D, which were quantified by Software Postural Assessment. The functional exercise capacity was assessed by a portable gas analyzer during the incremental shuttle walk test (ISWT. Besides that, manovacuometry and spirometry were also performed.Results Linear regressions showed that oxygen uptake (peak VO2 was correlated with distance travelled in the ISWT (R2 = 0.52, maximal respiratory pressures, cough peak flow (R2 = 0.59 and some thoracic deformity markers (D1, D2 and A6.Discussion We observed that the chest wall alterations, lung function and respiratory muscle strength are related to the functional exercise capacity and may impair the physical activity performance in AIS patients.Final considerations There is correlation between functional exercise capacity, lung function and geometry of the chest in AIS patients. Our results point to the possible impact of the AIS in the physical activities of these adolescents. Therefore, efforts to prevent the disease progression are extremely important.

  8. Analysis of Peak-to-Peak Current Ripple Amplitude in Seven-Phase PWM Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2013-08-01

    Full Text Available Multiphase systems are nowadays considered for various industrial applications. Numerous pulse width modulation (PWM schemes for multiphase voltage source inverters with sinusoidal outputs have been developed, but no detailed analysis of the impact of these modulation schemes on the output peak-to-peak current ripple amplitude has been reported. Determination of current ripple in multiphase PWM voltage source inverters is important for both design and control purposes. This paper gives the complete analysis of the peak-to-peak current ripple distribution over a fundamental period for multiphase inverters, with particular reference to seven-phase VSIs. In particular, peak-to-peak current ripple amplitude is analytically determined as a function of the modulation index, and a simplified expression to get its maximum value is carried out. Although reference is made to the centered symmetrical PWM, being the most simple and effective solution to maximize the DC bus utilization, leading to a nearly-optimal modulation to minimize the RMS of the current ripple, the analysis can be readily extended to either discontinuous or asymmetrical modulations, both carrier-based and space vector PWM. A similar approach can be usefully applied to any phase number. The analytical developments for all different sub-cases are verified by numerical simulations.

  9. The cost of electrolytic hydrogen from off-peak power

    International Nuclear Information System (INIS)

    Stucki, S.

    1991-01-01

    The cost of electrolytic hydrogen depends on the capacity factor of the plant and the cost of electricity. Both these parameters are correlated if off-peak power is to be used for hydrogen production. Based on assumptions regarding the correlation between the electricity price and the availability of electric power, optimizations were run using a simple cost model for the electrolysis plant. The current density at which the electrolysis plant would be run is taken as a variable for optimization as well as the annual time of availability of electric power. The results of the optimizations show for a number of hypothetical electrolyser types that the optimum operation time or electricity price do not depend much on the technology used. Production cost of electrolytic hydrogen can, however, be cut by 30% by using advanced electrolysis technology. (author)

  10. Total HDL cholesterol efflux capacity in healthy children - Associations with adiposity and dietary intakes of mother and child.

    Science.gov (United States)

    Khalil, H; Murrin, C; O'Reilly, M; Viljoen, K; Segurado, R; O'Brien, J; Somerville, R; McGillicuddy, F; Kelleher, C C

    2017-01-01

    High-density lipoprotein (HDL) cholesterol efflux capacity in adults may be a measure of the atheroprotective property of HDL. Little however, is known about HDL cholesterol efflux capacity in childhood. We aimed to investigate the relationship between HDL cholesterol efflux capacity and childhood anthropometrics in a longitudinal study. Seventy-five children (mean age = 9.4 ± 0.4 years) were followed from birth until the age of 9 years. HDL cholesterol efflux capacity was determined at age 9 by incubating serum-derived HDL-supernatants with 3 H-cholesterol labeled J774 macrophages and percentage efflux determined. Mothers provided dietary information by completing food frequency questionnaires in early pregnancy and then 5 years later on behalf of themselves and their children. Pearson's correlations and multiple regression analyses were conducted to confirm independent associations with HDL efflux. There was a negative correlation between HDL cholesterol efflux capacity and waist circumference at age 5 (r = -0.3, p = 0.01) and age 9 (r = -0.24, p = 0.04) and BMI at age 5 (r = -0.45, p = 0.01) and age 9 (r = -0.19, p = 0.1). Multiple regression analysis showed that BMI at age 5 remained significantly associated with reduced HDL cholesterol efflux capacity (r = -0.45, p < 0.001). HDL-C was negatively correlated with energy-adjusted fat intake (r = -0.24, p = 0.04) and positively correlated with energy-adjusted protein (r = 0.24, p = 0.04) and starch (r = 0.29, p = 0.01) intakes during pregnancy. HDL-C was not significantly correlated with children dietary intake at age 5. There were no significant correlations between maternal or children dietary intake and HDL cholesterol efflux capacity. This novel analysis shows that efflux capacity is negatively associated with adiposity in early childhood independent of HDL-C. Copyright © 2016 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the

  11. The Total Work Measured During a High Intensity Isokinetic Fatigue Test Is Associated With Anaerobic Work Capacity

    Directory of Open Access Journals (Sweden)

    Laurent Bosquet, Kenan Gouadec, Nicolas Berryman, Cyril Duclos, Vincent Gremeaux, Jean Louis Croisier

    2016-03-01

    Full Text Available The purpose of the study was to determine whether total work measured during a high intensity isokinetic fatigue test (TWFAT could be considered as a valid measure of anaerobic work capacity (AWC, such as determined by total work measured during a Wingate Anaerobic Test (TWWAnT. Twenty well-trained cyclists performed 2 randomly ordered sessions involving a high intensity isokinetic fatigue test consisting in 30 reciprocal maximal concentric contractions of knee flexors and extensors at 180°·s-1, and a Wingate Anaerobic Test. We found that TWFAT of knee extensors was largely lower than TWWAnT (4151 ± 691 vs 22313 ± 2901 J, respectively, p < 0.05, Hedge’s g = 4.27. Both measures were highly associated (r = 0.83, and the 95% limits of agreement (LoA represented 24.5% of TWWAnT. TWFAT of knee flexors (2151 ± 540 J was largely lower than TWWAnT (p < 0.05, g = 9.52. By contrast, both measures were not associated (r = 0.09, and the 95% LoA represented 31.1% of TWWAnT. Combining TWFAT of knee flexors and knee extensors into a single measure (6302 ± 818 J did not changed neither improved these observations. We still found a large difference with TWWAnT (p < 0.05, g = 5.26, a moderate association (r = 0.65 and 95% LoA representing 25.5% of TWWAnT. We concluded that TWFAT of knee extensors could be considered as a valid measure of AWC, since both measure were highly associated. However, the mean difference between both measures and their 95% LoA were too large to warrant interchangeability.

  12. Capacity factor of nuclear power stations in Japan in fiscal year 1984

    International Nuclear Information System (INIS)

    Agawa, Takashi

    1985-01-01

    In Japan presently a total of 28 nuclear power plants are in operation with aggregate capacity 20,561 MW, 22 % of the total power generation. Around 1975 there occurred such as stress corrosion cracking and to repair them much time was consumed, leading to the low capacity factor. With such troubles removed, in fiscal 1984, the capacity factor on average of the nuclear power stations is 73.9 %, the highest so far. Contributing to this are long period of the continuous operation, short period of the periodical inspection and increase in the in-operation capacity factor. Contents are the following : construction state of nuclear power stations, operation state in fiscal 1984, causes leading to the high capacity factor, future directions. (Mori, K.)

  13. Balance sheet capacity and endogenous risk

    OpenAIRE

    Jon Danielsson; Hyun Song Shin; Jean-Pierre Zigrand

    2011-01-01

    Banks operating under Value-at-Risk constraints give rise to a well-defined aggregate balance sheet capacity for the banking sector as a whole that depends on total bank capital. Equilibrium risk and market risk premiums can be solved in closed form as functions of aggregate bank capital. We explore the empirical properties of the model in light of recent experience in the financial crisis and highlight the importance of balance sheet capacity as the driver of the financial cycle and market r...

  14. How to use your peak flow meter

    Science.gov (United States)

    ... meter - how to use; Asthma - peak flow meter; Reactive airway disease - peak flow meter; Bronchial asthma - peak ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  15. Serum total anti-oxidant capacity of some Nigerian cigarette smokers

    African Journals Online (AJOL)

    Abstract. Cigarette smoke has been reported to contain free radicals. The interaction of these free radicals with the body defense system and associated health risk among Nigerian smokers have remained scarcely investigated despite the high numbers of smokers in our society. This study thus, investigates the serum total ...

  16. Effect of Body Mass Index on Exercise Capacity in Patients With Hypertrophic Cardiomyopathy.

    Science.gov (United States)

    Larsen, Carolyn M; Ball, Caroline A; Hebl, Virginia B; Ong, Kevin C; Siontis, Konstantinos C; Olson, Thomas P; Ackerman, Michael J; Ommen, Steve R; Allison, Thomas G; Geske, Jeffrey B

    2018-01-01

    The objective of this study was to evaluate the relation between body mass index (BMI), exercise capacity, and symptoms in patients with hypertrophic cardiomyopathy (HC) and to utilize results of cardiopulmonary exercise tests (CPX) and transthoracic echocardiograms to understand the mechanism(s) of reduced exercise capacity across body mass index groups. Over a 6-year period, 510 consecutive patients with HC seen at a tertiary referral center underwent (CPX) and a transthoracic echocardiogram. Increasing BMI was associated with decreased exercise capacity as assessed by peak VO 2 (ml/kg/min). However, the prevalence of cardiac impairment did not vary by BMI group. In conclusion, these findings suggest that in some patients with hypertrophic cardiomyopathy, cardiac impairment is not the primary cause of exercise limitation and weight loss may result in improved exercise capacity. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Evaluation of anaerobic capacity in soccer players using a maximal shuttle run test

    Directory of Open Access Journals (Sweden)

    Alexandre Gomes de Almeida

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n1p88   The aim of this study was to investigate whether a 300-m shuttle run test predicts anaerobic capacity, expressed as mean power output in the Wingate test, in a group of professional soccer players. Twenty-one soccer players (21 ± 2 years; 76.8 ± 7.0 kg; 179.8 ± 6.7 cm from a first division team of the São Paulo Soccer Federation participated in the study. In the first session, the players were submitted to the Wingate test for the determination of relative peak power output, relative mean power output and fatigue index. In the second session, the players underwent a shuttle run test which consisted of a maximum sprint of 20 m at the highest speed possible until completing a distance of 300 m. The total run time and mean velocity over the 20 m (V20m were recorded. Blood samples were collected before and after the 300-m shuttle run test for the determination of lactate concentration ([LAC]. Pearson’s correlation between the Wingate and 300-m shuttle run test variables showed that only relative mean power output was significantly correlated with total run time (r = - 0.75 and V20m (r = 0.72. [LAC] showed a significant increase (p < 0.05 when comparing the values obtained before (2.1 ± 1.0 mM and after (14.3 ± 2.4 mM the shuttle run test. In conclusion, this study demonstrated that the 300-m shuttle run test can predict anaerobic capacity in professional soccer players.

  18. Logistic curves, extraction costs and effective peak oil

    International Nuclear Information System (INIS)

    Brecha, Robert J.

    2012-01-01

    Debates about the possibility of a near-term maximum in world oil production have become increasingly prominent over the past decade, with the focus often being on the quantification of geologically available and technologically recoverable amounts of oil in the ground. Economically, the important parameter is not a physical limit to resources in the ground, but whether market price signals and costs of extraction will indicate the efficiency of extracting conventional or nonconventional resources as opposed to making substitutions over time for other fuels and technologies. We present a hybrid approach to the peak-oil question with two models in which the use of logistic curves for cumulative production are supplemented with data on projected extraction costs and historical rates of capacity increase. While not denying the presence of large quantities of oil in the ground, even with foresight, rates of production of new nonconventional resources are unlikely to be sufficient to make up for declines in availability of conventional oil. Furthermore we show how the logistic-curve approach helps to naturally explain high oil prices even when there are significant quantities of low-cost oil yet to be extracted. - Highlights: ► Extraction cost information together with logistic curves to model oil extraction. ► Two models of extraction sequence for different oil resources. ► Importance of time-delay and extraction rate limits for new resources. ► Model results qualitatively reproduce observed extraction cost dynamics. ► Confirmation of “effective” peak oil, even though resources are in ground.

  19. Growth Hormone Improves Cardiopulmonary Capacity and Body Composition in Children With Growth Hormone Deficiency.

    Science.gov (United States)

    Capalbo, Donatella; Barbieri, Flavia; Improda, Nicola; Giallauria, Francesco; Di Pietro, Elisa; Rapacciuolo, Antonio; Di Mase, Raffaella; Vigorito, Carlo; Salerno, Mariacarolina

    2017-11-01

    Growth hormone deficiency (GHD) in children may be associated with early cardiovascular risk factors and alterations in left ventricular (LV) structure and function; data on cardiopulmonary functional capacity are lacking. Aim of the study was to evaluate the effect of GHD and growth hormone (GH) therapy on cardiopulmonary functional capacity, left and right cardiac structure and function, and body composition in children and adolescents. Prospective, case-control study. Twenty-one untrained GHD children (11.3 ± 0.8 years) underwent cardiopulmonary exercise testing, echocardiography and dual-energy x-ray absorptiometry, before and after 12 months of GH therapy. Twenty-one controls matched for sex, pubertal status, body mass index, and physical activity (PA) were evaluated at baseline and after 1 year. At baseline, GHD patients showed reduced LV mass (LVM; 63.32 ± 7.80 vs 80.44 ± 26.29 g/m2, P = 0.006), peak oxygen consumption (VO2peak; 22.92 ± 4.80 vs 27.48 ± 6.71 mL/Kg/min, P = 0.02), peak workload (80.62 ± 29.32 vs 103.76 ± 36.20 W, P = 0.02), and O2 pulse (4.93 ± 1.30 vs 7.67 ± 2.93 mL/beat, P = 0.0003), compared with controls. GHD patients also exhibited lower lean body mass (LBM 65.36 ± 7.84% vs 76.13 ± 8.23%, P controls. GH therapy resulted in a significant increase of LVM (72.01 ± 15.88, P = 0.03), VO2peak (26.80 ± 4.97; P = 0.01), peak workload (103.67 ± 32.24, P = 0.001), O2 pulse (6.64 ± 1.68, P = 0.0007), and LBM (75.36 ± 7.59%, P = 0.0001), with a reduction in FM (22.62 ± 7.73%, P = 0.001). No difference was found in either left or right ventricular function. Our results suggest that cardiac structure, body composition and cardiopulmonary functional capacity are impaired in children with untreated GHD and can be restored after short-term GH replacement therapy. Copyright © 2017 Endocrine Society

  20. Effect of high-intensity training versus moderate training on peak oxygen uptake and chronotropic response in heart transplant recipients

    DEFF Research Database (Denmark)

    Dall, C H; Snoer, M; Christensen, S

    2014-01-01

    In heart transplant (HTx) recipients, there has been reluctance to recommend high-intensity interval training (HIIT) due to denervation and chronotropic impairment of the heart. We compared the effects of 12 weeks' HIIT versus continued moderate exercise (CON) on exercise capacity and chronotropic...... response in stable HTx recipients >12 months after transplantation in a randomized crossover trial. The study was completed by 16 HTx recipients (mean age 52 years, 75% males). Baseline peak oxygen uptake (VO2peak ) was 22.9 mL/kg/min. HIIT increased VO2peak by 4.9 ± 2.7 mL/min/kg (17%) and CON by 2.6 ± 2.......2 mL/kg/min (10%) (significantly higher in HIIT; p HIIT, systolic blood pressure decreased significantly (p = 0.037) with no significant change in CON (p = 0.241; between group difference p = 0.027). Peak heart rate (HRpeak ) increased significantly by 4.3 beats per minute (p = 0...

  1. Evaluation of the level of skill required of operators of a computer-assisted radiologic total lung capacity measurement system

    International Nuclear Information System (INIS)

    Mazzeo, J.

    1985-01-01

    This research was conducted to obtain information regarding the feasibility of using non-medical personnel to obtain measurements of radiologic total lung capacity (TLC). Operators from each of four groups (general undergraduates, nursing students, medical students, radiologists) differing in the amount of medical training and/or experience reading x-rays, performed each of two tasks. The first task was the measurement of radiologic TLC for a set of twenty x-rays. The second task consisted of tracing the outline of the anatomical structures that must be identified in the execution of the radiologic TLC measurement task. Data from the radiologic TLC measurement task were used to identify possible group differences in the reliability and validity of the measures. The reliability analyses were performed within the framework of Generalizability Theory. While the results are not conclusive, due to small sizes, the analyses suggest that group differences in reliability of the measures, if they exist, are small

  2. Influence of Distributed Residential Energy Storage on Voltage in Rural Distribution Network and Capacity Configuration

    Science.gov (United States)

    Liu, Lu; Tong, Yibin; Zhao, Zhigang; Zhang, Xuefen

    2018-03-01

    Large-scale access of distributed residential photovoltaic (PV) in rural areas has solved the voltage problem to a certain extent. However, due to the intermittency of PV and the particularity of rural residents’ power load, the problem of low voltage in the evening peak remains to be resolved. This paper proposes to solve the problem by accessing residential energy storage. Firstly, the influence of access location and capacity of energy storage on voltage distribution in rural distribution network is analyzed. Secondly, the relation between the storage capacity and load capacity is deduced for four typical load and energy storage cases when the voltage deviation meets the demand. Finally, the optimal storage position and capacity are obtained by using PSO and power flow simulation.

  3. Changes in serum iron, total iron binding capacity and transferrin ...

    African Journals Online (AJOL)

    Background: Iron is a vital constituent of cells but in excess may be harmful and is associated with a raised risk for some malignant diseases including breast cancer. We aimed to study changes in iron profile in Sudanese females newly diagnosed with breast cancer. Methods: A case- control study in which serum iron, Total ...

  4. Absorptive capacity, technological innovation, and product life cycle: a system dynamics model.

    Science.gov (United States)

    Zou, Bo; Guo, Feng; Guo, Jinyu

    2016-01-01

    While past research has recognized the importance of the dynamic nature of absorptive capacity, there is limited knowledge on how to generate a fair and comprehensive analytical framework. Based on interviews with 24 Chinese firms, this study develops a system-dynamics model that incorporates an important feedback loop among absorptive capacity, technological innovation, and product life cycle (PLC). The simulation results reveal that (1) PLC affects the dynamic process of absorptive capacity; (2) the absorptive capacity of a firm peaks in the growth stage of PLC, and (3) the market demand at different PLC stages is the main driving force in firms' technological innovations. This study also explores a sensitivity simulation using the variables of (1) time spent in founding an external knowledge network, (2) research and development period, and (3) knowledge diversity. The sensitivity simulation results show that the changes of these three variables have a greater impact on absorptive capacity and technological innovation during growth and maturity stages than in the introduction and declining stages of PLC. We provide suggestions on how firms can adjust management policies to improve their absorptive capacity and technological innovation performance during different PLC stages.

  5. A thermal storage capacity market for non dispatchable renewable energies

    Science.gov (United States)

    Bennouna, El Ghali; Mouaky, Ammar; Arrad, Mouad; Ghennioui, Abdellatif; Mimet, Abdelaziz

    2017-06-01

    Due to the increasingly high capacity of wind power and solar PV in Germany and some other European countries and the high share of variable renewable energy resources in comparison to fossil and nuclear capacity, a power reserve market structured by auction systems was created to facilitate the exchange of balance power capacities between systems and even grid operators. Morocco has a large potential for both wind and solar energy and is engaged in a program to deploy 2000MW of wind capacity by 2020 and 3000 MW of solar capacity by 2030. Although the competitiveness of wind energy is very strong, it appears clearly that the wind program could be even more ambitious than what it is, especially when compared to the large exploitable potential. On the other hand, heavy investments on concentrated solar power plants equipped with thermal energy storage have triggered a few years ago including the launching of the first part of the Nour Ouarzazate complex, the goal being to reach stable, dispatchable and affordable electricity especially during evening peak hours. This paper aims to demonstrate the potential of shared thermal storage capacity between dispatchable and non dispatchable renewable energies and particularly CSP and wind power. Thus highlighting the importance of a storage capacity market in parallel to the power reserve market and the and how it could enhance the development of both wind and CSP market penetration.

  6. Intestinal intraluminal injection of glutamine increases trolox total equivalent antioxidant capacity (TEAC in hepatic ischemia-reperfusion Injeção na luz intestinal de glutamina aumenta a capacidade anti-oxidante total em equivalência ao trolox (TEAC na isquemia-reperfusão hepática

    Directory of Open Access Journals (Sweden)

    Alberto Bicudo Salomão

    2006-01-01

    Full Text Available PURPOSE: To evaluate the effects of intraluminal injection of glutamine on the serum trolox equivalent antioxidant capacity in an experimental model of ischemia-reperfusion of the liver observing the applicability of modifications on the original assay method. METHODS: Thirty Wistar rats underwent laparotomy to perform a 20 cm blind sac of small bowel and occlusion of the hepatic hilo for 30 minutes and reperfusion for 5 minutes. Into the gut sac it was injected glutamine (glutamine group, n=10 or distilled water (control group, n=10. Ten other animals (sham group underwent laparotomy without artery occlusion. Blood samples were collected for trolox equivalent antioxidant capacity assays in different temperature conditions, reagent quantities and time for spectrophotometer readings. RESULTS: Total antioxidant capacity was significantly greater in glutamine group than in both control group (1,60[1,55-1,77] vs 1,44[1,27-1,53] and sham group (1,60[1,55-1,77] vs 1,48[1,45-1,59]. CONCLUSION: Glutamine enhanced serum antioxidant capacity. The assay technique consistently reflected the changes in the antioxidant defenses in this experimental model.OBJETIVO: Avaliar em um modelo experimental de isquemia-reperfusão hepática os efeitos da injeção intraluminal de glutamina na capacidade anti-oxidante total em equivalência ao trolox (TEAC do plasma, verificando a aplicabilidade de modificações ao método original de dosagem. MÉTODOS: Trinta ratos Wistar foram submetidos a laparotomia e confecção de uma alça fechada de 20 cm de comprimento envolvendo o intestinal delgado distal seguido do clampeamento do hilo hepático por 30 minutos e reperfusão por 5 minutos. Na alça fechada foi injetada glutamina (grupo glutamina; n=10 ou água destilada (grupo controle; n=10. Em dez animais (grupo sham não foi realizado clampeamento hilar. Coletou-se sangue para dosagem da capacidade antioxidante total em equivalência ao trolox em condições modificadas

  7. Cranial Indicators Identified for Peak Incidence of Otitis Media.

    Science.gov (United States)

    Pagano, Anthony S; Wang, Eugene; Yuan, Derek; Fischer, Daniel; Bluestone, Charles; Marquez, Samuel; Laitman, Jeffrey

    2017-10-01

    Acute otitis media (AOM) is one of the most common pediatric conditions worldwide. Peak age of occurrence for AOM has been identified within the first postnatal year and it remains frequent until approximately six postnatal years. Morphological differences between adults and infants in the cartilaginous Eustachian tube (CET) and associated structures may be responsible for development of this disease yet few have investigated normal growth trajectories. We tested hypotheses on coincidence of skeletal growth changes and known ages of peak AOM occurrence. Growth was divided into five dental eruption stages ranging from edentulous neonates (Stage 1) to adults with erupted third maxillary molars (Stage 5). A total of 32 three-dimensional landmarks were used and Generalized Procrustes Analysis was performed. Next, we performed principal components analysis and calculated univariate measures. It was found that growth change in Stage 1 was the most rapid and comprised the largest amount of overall growth in upper respiratory tract proportions (where time is represented by the natural logarithmic transformation of centroid size). The analysis of univariate measures showed that Stage 1 humans did indeed possess the relatively shortest and most horizontally oriented CET's with the greatest amount of growth change occurring at the transition to Stage 2 (eruption of deciduous dentition at five postnatal months, commencing peak AOM incidence) and ceasing by Stage 3 (approximately six postnatal years). Skeletal indicators appear related to peak ages of AOM incidence and may contribute to understanding of a nearly ubiquitous human disease. Anat Rec, 2017. © 2017 Wiley Periodicals, Inc. Anat Rec, 300:1721-1740, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. Effect of Microwave-Assisted Extraction on the Phenolic Compounds and Antioxidant Capacity of Blackthorn Flowers.

    Science.gov (United States)

    Lovrić, Vanja; Putnik, Predrag; Kovačević, Danijela Bursać; Jukić, Marijana; Dragović-Uzelac, Verica

    2017-06-01

    This research was undertaken to investigate the influence of extraction parameters during microwave-assisted extraction on total phenolic content, total flavonoids, total hydroxycinnamic acids and total flavonols of blackthorn flowers as well as to evaluate the antioxidant capacity by two different methods (2,2-diphenyl-1-picrylhydrazyl free radical scavenging capacity and ferric reducing antioxidant power assays). The investigated extraction parameters were: solvent type and volume fraction of alcohol in solvent (50 and 70% aqueous solutions of ethanol and methanol), extraction time (5, 15 and 25 min) and extraction temperature (40, 50 and 60 °C) controlled by microwave power of 100, 200 and 300 W. Multivariate analysis of variance (MANOVA) was used to evaluate the differences at a 95% confidence level (p≤0.05). The obtained results show that aqueous solution of ethanol was more appropriate solvent for extraction of phenolic compounds (total flavonoids, total hydroxycinnamic acids and total flavonols) than aqueous solution of methanol. The amount of phenolic compounds was higher in 70% aqueous solution of ethanol or methanol, while higher antioxidant capacity was observed in 50% aqueous solution of methanol. Higher temperature of extraction improved the amount of phenolic compounds and also antioxidant capacity determined by 2,2-diphenyl-1-picrylhydrazyl free radical scavenging capacity assay. Extensive duration of extraction (15- to 25-minute interval) has a significant effect only on the increase of total phenolic content, while specific phenolic compound content and antioxidant capacity were the highest when microwave extraction time of 5 min was applied.

  9. Effect of Microwave-Assisted Extraction on the Phenolic Compounds and Antioxidant Capacity of Blackthorn Flowers

    Directory of Open Access Journals (Sweden)

    Vanja Lovrić

    2017-01-01

    Full Text Available This research was undertaken to investigate the influence of extraction parameters during microwave-assisted extraction on total phenolic content, total flavonoids, total hydroxycinnamic acids and total flavonols of blackthorn flowers as well as to evaluate the antioxidant capacity by two different methods (2,2-diphenyl-1 picrylhydrazyl free radical scavenging capacity and ferric reducing antioxidant power assays. The investigated extraction parameters were: solvent type and volume fraction of alcohol in solvent (50 and 70 % aqueous solutions of ethanol and methanol, extraction time (5, 15 and 25 min and extraction temperature (40, 50 and 60 °C controlled by microwave power of 100, 200 and 300 W. Multivariate analysis of variance (MANOVA was used to evaluate the differences at a 95 % confidence level (p≤0.05. The obtained results show that aqueous solution of ethanol was more appropriate solvent for extraction of phenolic compounds (total flavonoids, total hydroxycinnamic acids and total flavonols than aqueous solution of methanol. The amount of phenolic compounds was higher in 70 % aqueous solution of ethanol or methanol, while higher antioxidant capacity was observed in 50 % aqueous solution of methanol. Higher temperature of extraction improved the amount of phenolic compounds and also antioxidant capacity determined by 2,2-diphenyl-1-picrylhydrazyl free radical scavenging capacity assay. Extensive duration of extraction (15- to 25-minute interval has a significant effect only on the increase of total phenolic content, while specific phenolic compound content and antioxidant capacity were the highest when microwave extraction time of 5 min was applied.

  10. Automated asteroseismic peak detections

    Science.gov (United States)

    García Saravia Ortiz de Montellano, Andrés; Hekker, S.; Themeßl, N.

    2018-05-01

    Space observatories such as Kepler have provided data that can potentially revolutionize our understanding of stars. Through detailed asteroseismic analyses we are capable of determining fundamental stellar parameters and reveal the stellar internal structure with unprecedented accuracy. However, such detailed analyses, known as peak bagging, have so far been obtained for only a small percentage of the observed stars while most of the scientific potential of the available data remains unexplored. One of the major challenges in peak bagging is identifying how many solar-like oscillation modes are visible in a power density spectrum. Identification of oscillation modes is usually done by visual inspection that is time-consuming and has a degree of subjectivity. Here, we present a peak-detection algorithm especially suited for the detection of solar-like oscillations. It reliably characterizes the solar-like oscillations in a power density spectrum and estimates their parameters without human intervention. Furthermore, we provide a metric to characterize the false positive and false negative rates to provide further information about the reliability of a detected oscillation mode or the significance of a lack of detected oscillation modes. The algorithm presented here opens the possibility for detailed and automated peak bagging of the thousands of solar-like oscillators observed by Kepler.

  11. Degree of thoracic kyphosis and peak torque of trunk flexors and extensors among healthy women.

    Science.gov (United States)

    Granito, Renata Neves; Aveiro, Mariana Chaves; Rennó, Ana Claudia Muniz; Oishi, Jorge; Driusso, Patricia

    2014-01-01

    The aim of this study was to analyze the effects of aging on the degree of thoracic kyphosis and peak torque of the trunk flexor and extensor muscles among women without a densitometric diagnosis of osteoporosis. Thirty women were selected to make up three groups: young women (n = 10; 24.60 ± 2.27 years of age); adults (n = 10; 43.50 ± 2.88); and elderly women (n = 10; 62.40 ± 2.67). Bone mineral density (BMD), degree of thoracic kyphosis and peak torque of the trunk flexors and extensors were evaluated. Differences between the groups were evaluated using the Kruskal-Wallis ANOVA and Mann-Whitney U tests. Pearson's correlation coefficient was used to assess correlations between the variables. The significance level was taken to be 5% (p ≤ 0.05). The elderly group presented a greater degree of thoracic kyphosis (p = 0.009) and lower peak torque of the trunk flexors and extensors than the young group. The adult group presented lower peak torque of the trunk than the young group. A negative correlation was observed between age and peak torque of the trunk flexors and extensors (p ≤ 0.001), and a positive correlation between age and the degree of thoracic kyphosis (r = 0.58; p ≤ 0.001). The elderly group presented higher values for the eccentric/concentric ratio of the peak torque for flexors (p = 0.03) and extensors (p = 0.02). This study suggests that physiological aging may be associated with a greater degree of thoracic kyphosis and lower muscle strength of the trunk flexors and extensors. Moreover, the elderly women showed a relative capacity for preservation of eccentric strength.

  12. Degree of thoracic kyphosis and peak torque of trunk flexors and extensors among healthy women,

    Directory of Open Access Journals (Sweden)

    Renata Neves Granito

    2014-06-01

    Full Text Available OBJECTIVE: The aim of this study was to analyze the effects of aging on the degree of thoracic kyphosis and peak torque of the trunk flexor and extensor muscles among women without a densitometric diagnosis of osteoporosis.METHODS: Thirty women were selected to make up three groups: young women (n = 10; 24.60 ± 2.27 years of age; adults (n = 10; 43.50 ± 2.88; and elderly women (n= 10; 62.40 ± 2.67. Bone mineral density (BMD, degree of thoracic kyphosis and peak torque of the trunk flexors and extensors were evaluated. Differences between the groups were evaluated using the Kruskal-Wallis ANOVA and Mann-Whitney U tests. Pearson's correlation coefficient was used to assess correlations between the variables. The significance level was taken to be 5% (p < 0.05.RESULTS: The elderly group presented a greater degree of thoracic kyphosis (p = 0.009 and lower peak torque of the trunk flexors and extensors than the young group. The adult group presented lower peak torque of the trunk than the young group. A negative correlation was observed between age and peak torque of the trunk flexors and extensors (p < 0.001, and a positive correlation between age and the degree of thoracic kyphosis (r = 0.58; p < 0.001. The elderly group presented higher values for the eccentric/concentric ratio of the peak torque for flexors (p = 0.03 and extensors (p = 0.02.CONCLUSION: This study suggests that physiological aging may be associated with a greater degree of thoracic kyphosis and lower muscle strength of the trunk flexors and extensors. Moreover, the elderly women showed a relative capacity for preservation of eccentric strength.

  13. Metabolic syndrome in people with a long-standing spinal cord injury: associations with physical activity and capacity.

    Science.gov (United States)

    de Groot, Sonja; Adriaansen, Jacinthe J; Tepper, Marga; Snoek, Govert J; van der Woude, Lucas H V; Post, Marcel W M

    2016-11-01

    This study investigated (i) the prevalence of the metabolic syndrome (MetS) in people with a long-standing spinal cord injury (SCI); (ii) whether personal or lesion characteristics are determinants of the MetS; and (iii) the association with physical activity or peak aerobic capacity on the MetS. In a cross-sectional study, persons with SCI (N = 223; time since injury of ≥10 years) were tested. The individual components of the MetS were assessed together with the physical activity measured by the Physical Activity Scale for Individuals with Physical Disabilities (PASIPD), while peak aerobic capacity was tested during a graded wheelchair exercise test on a treadmill. Thirty-nine percent of the participants had MetS. In a multivariate logistic regression analyses and after performing a backward regression analysis, only age and education were significant determinants of the MetS. A 10-year increase in age leads to a 1.5 times more chance to have the MetS. Furthermore, people with a low education will multiply the relative risk of MetS compared with people with high education by almost 2. With and without correcting for confounders, no significant relationship was found between PASIPD or peak aerobic capacity and the MetS. It can be concluded that the prevalence of the MetS is high (39%) in people with a long-standing SCI but is comparable to the general Dutch population. Older people and those with a lower education level are most at risk for the MetS. Physical activity and peak aerobic fitness were not related to the MetS in this group with a long-standing SCI.

  14. Peak Velocity as an Alternative Method for Training Prescription in Mice.

    Science.gov (United States)

    Picoli, Caroline de Carvalho; Romero, Paulo Vitor da Silva; Gilio, Gustavo R; Guariglia, Débora A; Tófolo, Laize P; de Moraes, Solange M F; Machado, Fabiana A; Peres, Sidney B

    2018-01-01

    Purpose: To compare the efficiency of an aerobic physical training program prescribed according to either velocity associated with maximum oxygen uptake (vVO 2max ) or peak running speed obtained during an incremental treadmill test (V peak_K ) in mice. Methods: Twenty male Swiss mice, 60 days old, were randomly divided into two groups with 10 animals each: 1. group trained by vVO 2max (GVO 2 ), 2. group trained by V peak_K (GVP). After the adaptation training period, an incremental test was performed at the beginning of each week to adjust training load and to determine the amount of VO 2 and VCO 2 fluxes consumed, energy expenditure (EE) and run distance during the incremental test. Mice were submitted to 4 weeks of aerobic exercise training of moderate intensity (velocity referring to 70% of vVO 2max and V peak_K ) in a programmable treadmill. The sessions lasted from 30 to 40 min in the first week, to reach 60 min in the fourth week, in order to provide the mice with a moderate intensity exercise, totaling 20 training sessions. Results: Mice demonstrated increases in VO 2max (ml·kg -1 ·min -1 ) (GVO 2 = 49.1% and GVP = 56.2%), V peak_K (cm·s -1 ) (GVO 2 = 50.9% and GVP = 22.3%), EE (ml·kg -0,75 ·min -1 ) (GVO 2 = 39.9% and GVP = 51.5%), and run distance (cm) (GVO 2 = 43.5% and GVP = 33.4%), after 4 weeks of aerobic training (time effect, P < 0.05); there were no differences between the groups. Conclusions: V peak_K , as well as vVO 2max , can be adopted as an alternative test to determine the performance and correct prescription of systemized aerobic protocol training to mice.

  15. Simultaneous collection method of on-peak window image and off-peak window image in Tl-201 imaging

    International Nuclear Information System (INIS)

    Murakami, Tomonori; Noguchi, Yasushi; Kojima, Akihiro; Takagi, Akihiro; Matsumoto, Masanori

    2007-01-01

    Tl-201 imaging detects the photopeak (71 keV, in on-peak window) of characteristic X-rays of Hg-201 formed from Tl-201 decay. The peak is derived from 4 rays of different energy and emission intensity and does not follow in Gaussian distribution. In the present study, authors made an idea for the method in the title to attain the more effective single imaging, which was examined for its accuracy and reliability with phantoms and applied clinically to Tl-201 scintigraphy in a patient. The authors applied the triple energy window method for data acquisition: the energy window setting was made on Hg-201 X-rays photopeak in three of the lower (3%, L), main (72 keV, M) and upper (14%, U) windows with the gamma camera with 2-gated detector (Toshiba E. CAM/ICON). L, M and U images obtained simultaneously were then constructed to images of on-peak (L+M, Mock on-peak) and off-peak (M+U) window settings for evaluation. Phantoms for line source with Tl-201-containing swab and for multi-defect with acrylic plate containing Tl-201 solution were imaged in water. The female patient with thyroid cancer was subjected to preoperative scintigraphy under the defined conditions. Mock on-, off-peak images were found to be equivalent to the true (ordinary, clinical) on-, off-peak ones, and the present method was thought usable for evaluation of usefulness of off-peak window data. (R.T.)

  16. Impacts of Using Distributed Energy Resources to Reduce Peak Loads in Vermont

    Energy Technology Data Exchange (ETDEWEB)

    Ruth, Mark F. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lunacek, Monte S. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jones, Birk [Univ. of New Mexico, Albuquerque, NM (United States); Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-11-28

    To help the United States develop a modern electricity grid that provides reliable power from multiple resources as well as resiliency under extreme conditions, the U.S. Department of Energy (DOE) is leading the Grid Modernization Initiative (GMI) to help shape the future of the nation's grid. Under the GMI, DOE funded the Vermont Regional Initiative project to provide the technical support and analysis to utilities that need to mitigate possible impacts of increasing renewable generation required by statewide goals. Advanced control of distributed energy resources (DER) can both support higher penetrations of renewable energy by balancing controllable loads to wind and photovoltaic (PV) solar generation and reduce peak demand by shedding noncritical loads. This work focuses on the latter. This document reports on an experiment that evaluated and quantified the potential benefits and impacts of reducing the peak load through demand response (DR) using centrally controllable electric water heaters (EWHs) and batteries on two Green Mountain Power (GMP) feeders. The experiment simulated various hypothetical scenarios that varied the number of controllable EWHs, the amount of distributed PV systems, and the number of distributed residential batteries. The control schemes were designed with several objectives. For the first objective, the primary simulations focused on reducing the load during the independent system operator (ISO) peak when capacity charges were the primary concern. The second objective was to mitigate DR rebound to avoid new peak loads and high ramp rates. The final objective was to minimize customers' discomfort, which is defined by the lack of hot water when it is needed. We performed the simulations using the National Renewable Energy Laboratory's (NREL's) Integrated Energy System Model (IESM) because it can simulate both electric power distribution feeder and appliance end use performance and it includes the ability to simulate

  17. Modified egg as a nutritional supplement during peak brain development: a new target for fortification.

    Science.gov (United States)

    Shapira, Niva

    2009-01-01

    Though eggs have the unique capacity, like breastmilk, to concentrate essential nutrients required for early growth and brain development of offspring - i.e. n-3 PUFA, increasingly deficient and sources contaminated - cholesterol and allergy concerns often exclude them from perinatal recommendations. Egg's potential contribution of key nutrients required for peak brain development are re-evaluated vis-à-vis fortification, accessibility, and risks. Contributions of standard (USDA) and fortified (selected market-available) egg compositions to perinatal requirements for critical brain-supporting nutrients were compared to human and cow milks, and risks and recommendations evaluated. Standard egg has already higher concentrations/kcal of iron, selenium, zinc, choline, vitamins B12 and E, and essential amino acids (plus taurine) than human milk. Fortified egg could further yield significant n-3 PUFA % recommendations for pregnancy-lactation (total n-3 69.6-75.0% [DRI=1400-1300 mg/day]), including DHA (120.1-129.3%, mostly approximately 80% [calculated DRI=140-130 mg/day]), plus antioxidant vitamins A (9.0-15.2%) and E (51.6-65.3%), and minerals iodine (33.6-44.5%) and selenium (33.7-39.3%); % recommendations for children (1-3 y) even more. Cholesterol, important for nerve membranes and learning, may not be generally contraindicated in childbearing-aged women (approximately 10.5% hypercholesterolemia), and early-life egg exposure may increase tolerance. Egg-inclusive perinatal nutrition programs have shown significant contributions. Eggs, especially target-fortified, may provide a unique nutritional supplement for peak brain development continously during pregnancy, nursing, and infancy (from 6 months), especially vs. insufficiencies. Missing nutritional opportunities by egg exclusion vs. concerns of hypercholesterolemia or allergy could be addressed individually, rather than as general recommendations, warranting further research and targeted egg design.

  18. Regulatory Approaches for Adding Capacity to Existing Hydropower Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Levine, Aaron L. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Curtis, Taylor L. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kazerooni, Borna [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-24

    In 2015, hydroelectric generation accounted for more than 6 percent of total net electricity generation in the United States and 46 percent of electricity generation from all renewables. The United States has considerable hydroelectric potential beyond what is already being developed. Nearly 7 GW of this potential is found by adding capacity to existing hydropower facilities. To optimize the value of hydroelectric generation, the U.S. Department of Energy's Hydropower Vision Study highlights the importance of adding capacity to existing facilities. This report provides strategic approaches and considerations for Federal Energy Regulatory Commission licensed and exempt hydropower facilities seeking to increase generation capacity, which may include increases from efficiency upgrades. The regulatory approaches reviewed for this report include capacity and non-capacity amendments, adding capacity during relicensing, and adding capacity when converting a license to a 10-MW exemption.

  19. Salivary Total Antioxidant Capacity and Lipid Peroxidation in Patients with Erosive Oral Lichen Planus

    Directory of Open Access Journals (Sweden)

    Atena Shirzad

    2014-03-01

    Full Text Available Background and aims. Oral lichen planus is a common chronic inflammatory disease of the oral mucosa with malignant potential, pathogenesis of which is not still well known. Free radicals and reactive oxygen species can play an important role in the pathogenesis of oral lichen planus. The aim of this study was to investigate salivary oxidative stress and antioxidant systems in patients with oral lichen planus. Materials and methods. In this case-control study, 30 patients with oral lichen planus (case group and 30 age- and gender-matched healthy subjects (control group, referring to Dental School of Babol University of Medical Sciences, were selected using simple sampling method. Unstimulated saliva of the two groups was collected. Salivary total antioxidant capacity (TAC and lipid peroxidation products were investigated and compared, using ferric reducing antioxidant power (FRAP and thiobarbituric acid reactive substance (TBARS methods, respectively. Data were analyzed using Student’s ttest. Results. The mean and standard deviation of salivary TAC in patients with oral lichen planus (297.23 ± 149.72 μM was significantly lower than that in the controls (791.43±183.95 μM; P < 0.0001, and mean and standard deviation of salivary malondialdehyde (MDA (0.49 ± 0.30 μM was remarkably higher in oral lichen planus patients compared to the control group (0.15 ± 0.11 μM (P < 0.0001. TAC was also reduced in both groups in line with an increase in the level of MDA (P < 0.0001, r = −0.48. Conclusion. The results of this study suggested that an increase in oxidative stress and an imbalance in antioxidant defense system in the saliva of oral lichen planus patients may be involved in the pathogenesis of oral lichen planus.

  20. Salivary total antioxidant capacity and lipid peroxidation in patients with erosive oral lichen planus.

    Science.gov (United States)

    Shirzad, Atena; Pouramir, Mahdi; Seyedmajidi, Maryam; Jenabian, Niloofar; Bijani, Ali; Motallebnejad, Mina

    2014-01-01

    Background and aims. Oral lichen planus is a common chronic inflammatory disease of the oral mucosa with malignant potential, pathogenesis of which is not still well known. Free radicals and reactive oxygen species can play an important role in the pathogenesis of oral lichen planus. The aim of this study was to investigate salivary oxidative stress and antioxidant systems in patients with oral lichen planus. Materials and methods. In this case-control study, 30 patients with oral lichen planus (case group) and 30 age-and gender-matched healthy subjects (control group), referring to Dental School of Babol University of Medical Sciences, were selected using simple sampling method. Unstimulated saliva of the two groups was collected. Salivary total antioxidant capacity (TAC) and lipid peroxidation products were investigated and compared, using ferric reducing antioxidant power (FRAP) and thiobarbituric acid reactive substance (TBARS) methods, respectively. Data were analyzed using Student' t-test. Results. The mean and standard deviation of salivary TAC in patients with oral lichen planus (297.23 ± 149.72 μM) was significantly lower than that in the controls (791.43 ± 183.95 μM; P & 0.0001), and mean and standard deviation of salivary malondialdehyde (MDA) (0.49 ± 0.30 μM) was remarkably higher in oral lichen planus patients compared to the control group (0.15 ± 0.11 μM) (P & 0.0001). TAC was also reduced in both groups in line with an increase in the level of MDA (P & 0.0001, r = -0.48). Conclusion. The results of this study suggested that an increase in oxidative stress and an imbalance in antioxidant defense system in the saliva of oral lichen planus patients may be involved in the pathogenesis of oral lichen planus.

  1. Phenolic acids, anthocyanins, and antioxidant capacity in rice (Oryza sativa L.) grains at four stages of development after flowering.

    Science.gov (United States)

    Shao, Yafang; Xu, Feifei; Sun, Xiao; Bao, Jinsong; Beta, Trust

    2014-01-15

    This study investigated differences in total phenolic content (TPC), antioxidant capacity, and phenolic acids in free, conjugated and bound fractions of white (unpolished), red and black rice at 1-, 2-, and 3-weeks of grain development after flowering and at maturity. Unlike the TPC (mg/100g) of white rice (14.6-33.4) and red rice (66.8-422.2) which was significantly higher at 1-week than at later stages, the TPC of black rice (56.5-82.0) was highest at maturity. The antioxidant capacity measured by DPPH radical scavenging and ORAC methods generally followed a similar trend as TPC. Only black rice had detectable anthocyanins (26.5-174.7mg/100g). Cyanidin-3-glucoside (C3G) and peonidin-3-glucoside (P3G) were the main anthocyanins in black rice showing significantly higher levels at 2- and 3-weeks than at 1-week development and at maturity. At all stages, the phenolic acids existed mainly in the bound form as detected by HPLC and confirmed by LC-MS/MS. Black rice (20.1-31.7mg/100g) had higher total bound phenolic acids than white rice and red rice (7.0-11.8mg/100g). Protocatechuic acid was detected in red rice and black rice with relatively high levels at 1-week development (1.41mg/100g) and at maturity (4.48mg/100g), respectively. Vanillic acid (2.4-5.4mg/100g) was detected only in black rice where it peaked at maturity. p-Coumaric acid (black rice. Ferulic acid (4.0-17.9mg/100g), the most abundant bound phenolic acid, had an inconsistent trend with higher levels being observed in black rice where it peaked at maturity. Isoferulic acid levels (0.8-1.6mg/100g) were generally low with slightly elevated values being observed at maturity. Overall black rice had higher total bound phenolic acids than white and red rice while white rice at all stages of development after flowering. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Heat capacity and thermal expansion of the itinerant helimagnet MnSi

    International Nuclear Information System (INIS)

    Stishov, S M; Petrova, A E; Khasanov, S; Panova, G Kh; Shikov, A A; Lashley, J C; Wu, D; Lograsso, T A

    2008-01-01

    The heat capacity and thermal expansion of a high quality single crystal of MnSi were measured at ambient pressure at zero and high magnetic fields. The calculated magnetic entropy change in the temperature range 0-30 K is less than 0.1R, a low value that emphasizes the itinerant nature of magnetism in MnSi. A linear temperature term dominates the thermal expansion coefficient in the range 30-150 K, which correlates with an enhancement of the linear electronic term in the heat capacity. A surprising similarity among the variations of the heat capacity, thermal expansion coefficient and temperature derivative of the resistivity is observed through the phase transition in MnSi. Specific forms of the heat capacity, thermal expansion coefficient and temperature derivative of resistivity at the phase transition to a helical magnetic state near 29 K are interpreted as the combination of sharp first-order features and broad peaks or shallow valleys of as yet unknown origin. The appearance of these broad satellites probably hints at a frustrated magnetic state slightly above the transition temperature in MnSi

  3. Functional capacity and muscular abnormalities in subclinical hypothyroidism.

    Science.gov (United States)

    Reuters, Vaneska S; Teixeira, Patrícia de Fátima S; Vigário, Patrícia S; Almeida, Cloyra P; Buescu, Alexandre; Ferreira, Márcia M; de Castro, Carmen L N; Gold, Jaime; Vaisman, Mario

    2009-10-01

    Neuromuscular abnormalities and low exercise tolerance are frequently observed in overt hypothyroidism, but it remains controversial if they can also occur in subclinical hypothyroidism (sHT). The aim of this study is to evaluate neuromuscular symptoms, muscle strength, and exercise capacity in sHT, compared with healthy euthyroid individuals. A cross-sectional study was performed with 44 sHT and 24 euthyroid outpatients from a university hospital. Neuromuscular symptoms were questioned. Muscle strength was tested for neck, shoulder, arm, and hip muscle groups, using manual muscle testing (MMT). Quadriceps muscle strength was tested with a chair dynamometer and inspiratory muscle strength (IS) by a manuvacuometer. Functional capacity was estimated based on the peak of oxygen uptake (mL/kg/min), using the Bruce treadmill protocol. Cramps (54.8% versus 25.0%; P muscle strength by MMT and the coexistence of neuromuscular complaints in patients with sHT may indicate neuromuscular dysfunction.

  4. A simple dynamic energy capacity model

    International Nuclear Information System (INIS)

    Gander, James P.

    2012-01-01

    I develop a simple dynamic model showing how total energy capacity is allocated to two different uses and how these uses and their corresponding energy flows are related and behave through time. The control variable of the model determines the allocation. All the variables of the model are in terms of a composite energy equivalent measured in BTU's. A key focus is on the shadow price of energy capacity and its behavior through time. Another key focus is on the behavior of the control variable that determines the allocation of overall energy capacity. The matching or linking of the model's variables to real world U.S. energy data is undertaken. In spite of some limitations of the data, the model and its behavior fit the data fairly well. Some energy policy implications are discussed. - Highlights: ► The model shows how energy capacity is allocated to current output production versus added energy capacity production. ► Two variables in the allocation are the shadow price of capacity and the control variable that determines the allocation. ► The model was linked to U.S. historical energy data and fit the data quite well. ► In particular, the policy control variable was cyclical and consistent with the model. ► Policy implications relevant to the allocation of energy capacity are discussed briefly.

  5. Statistical analysis of the low-temperature dislocation peak of internal friction (Bordoni peak) in nanostructured copper

    International Nuclear Information System (INIS)

    Vatazhuk, E.N.; Natsik, V.D.

    2011-01-01

    The temperature-frequency dependence of internal friction in the nanostructured samples of Cu and fibred composite C-32 vol.%Nb with the sizes of structure fragments approx 200 nm is analyzed. Experiments are used as initial information for such analysis. The characteristic for the heavily deformed copper Bordoni peak, located nearby a temperature 90 K, was recorded on temperature dependence of vibration decrement (frequencies 73-350 kHz) in previous experiments. The peak is due to the resonance interaction of sound with the system of thermal activated relaxators, and its width considerably greater in comparison with the width of standard internal friction peak with the single relaxation time. Statistical analysis of the peak is made in terms of assumption that the reason of broadening is random activation energy dispersion of relaxators as a result of intense distortion of copper crystal structure. Good agreement of experimental data and Seeger theory considers thermal activated paired kinks at linear segments of dislocation lines, placed in potential Peierls relief valley, as relaxators of Bordoni peak, was established. It is shown that the registered peak height in experiment correspond to presence at the average one dislocation segment in the interior of crystalline grain with size of 200 nm. Empirical estimates for the critical Peierls stress σp ∼ 2x10 7 Pa and integrated density of the interior grain dislocations ρ d ∼ 10 13 m -2 are made. Nb fibers in the composite Cu-Nb facilitate to formation of nanostructured copper, but do not influence evidently on the Bordoni peak.

  6. Lifestyle predictors of oxidant and antioxidant enzyme activities and total antioxidant capacity in healthy women: a cross-sectional study.

    Science.gov (United States)

    Mahasneh, Amjad A; Zhang, Yali; Zhao, Hua; Ambrosone, Christine B; Hong, Chi-Chen

    2016-12-01

    The aim of this study was to identify demographic and modifiable lifestyle factors that may be related to endogenous oxidant and antioxidant activity measured in blood specimens from putatively healthy women recruited at the Roswell Park Cancer Institute (Buffalo, NY, USA). Total glutathione (TGSH), catalase (CAT), CuZn-superoxide dismutase (CuZn-SOD), glutathione peroxidase (GPx), glutathione reductase (GR), and myeloperoxidase (MPO) activity, and total antioxidant capacity (TAC) were measured in 124 healthy women, and associations with epidemiological factors were tested using general linear models. There were significant differences in oxidant and antioxidant enzyme activities according to lifestyle factors, after adjusting for duration of blood storage and season of blood draw. Compared to women who consumed ≤2.8 servings of fruits and vegetables daily, those consuming >5.3 servings had on average 31 % lower MPO activity (p-trend = 0.02), as a marker of oxidative stress, 16 % higher antioxidant GPx activity (p-trend = 0.08), and 9 % higher TAC (p-trend = 0.05). Obese women (body mass index, BMI ≥ 30) in contrast showed 17 % lower antioxidant GPx activity, 44 % higher MPO activity (p-trend = 0.03), and 10 % higher TAC (p-trend = 0.03) compared to women with normal BMI lifestyle factors and, therefore, may be potentially modifiable, with implications for risk reduction of chronic conditions related to oxidative stress.

  7. Capacity mechanisms: EU or National Issue? Are capacity remuneration mechanisms helping to build the market or just a symptom of what does not work?

    International Nuclear Information System (INIS)

    Parmigiani, Laura

    2012-10-01

    In a competitive energy system, generation investment choices are let to investors. It is then the responsibility of the market actors to invest and ensure peak, medium and base load generation, based on market perspectives and trends. If through actors' investments the stability of the system cannot be ensured (because, for example, peak generation is not sufficient to satisfy demand), some measures have to be taken. These can have economic and system integrity impacts on neighboring systems, especially if they are connected. This is precisely what is happening in the European electricity market. While the internal electricity market should be completed by 2014, the adoption by Member States of capacity remuneration mechanisms in an uncoordinated way may lead to new market distortions. Whereas national capacity remuneration mechanisms (CRMs) already exist in several European countries (e.g. Italy, Spain, Sweden), others have taken steps in the past months to implement CRMs (France, UK) or contemplated to introduce them (Germany). After the puzzle of more than 27 different regimes for incentivizing renewables, the same heterogeneity will appear in the capacity markets if no coherent and Europe-wide framework is proposed. While increased interconnections and market coupling will lead to more efficient and liquid markets at regional and EU levels, the opposite will happen if Member States adopt national solutions without looking beyond their borders. In order to understand why we have come this point, it is essential to start from the roots of the problem and to throw light on some false beliefs. It would be much easier to blame market liberalization and un-bundling or RES integration into the market. The truth is that both measures were important. Timing showed that the RES production is developing very fast and creates local over capacity in some national systems, while when there is no wind or sun, the conventional plants are still needed to supply the customers

  8. Inhibition delay increases neural network capacity through Stirling transform

    Science.gov (United States)

    Nogaret, Alain; King, Alastair

    2018-03-01

    Inhibitory neural networks are found to encode high volumes of information through delayed inhibition. We show that inhibition delay increases storage capacity through a Stirling transform of the minimum capacity which stabilizes locally coherent oscillations. We obtain both the exact and asymptotic formulas for the total number of dynamic attractors. Our results predict a (ln2) -N-fold increase in capacity for an N -neuron network and demonstrate high-density associative memories which host a maximum number of oscillations in analog neural devices.

  9. Effect of water cooking on antioxidant capacity of carotenoid-rich vegetables in Taiwan

    OpenAIRE

    Fuh-Juin Kao; Yu-Shan Chiu; Wen-Dee Chiang

    2014-01-01

    Carotenoid-rich green leafy vegetables including cilantro, Thai basil leaves, sweet potato leaves, and choy sum were selected to evaluate the effects of water cooking or boiling on their total carotenoid content (TCC), total phenolic content (TPC), and total antioxidant capacity (TAC). The percentage inhibition of peroxidation (%IP), Trolox equivalent antioxidant capacity (TEAC), and metal-chelating effect were used to evaluate TAC. The results indicated that TCC reached the maximum after boi...

  10. The peak in neutron powder diffraction

    International Nuclear Information System (INIS)

    Laar, B. van; Yelon, W.B.

    1984-01-01

    For the application of Rietveld profile analysis to neutron powder diffraction data a precise knowledge of the peak profile, in both shape and position, is required. The method now in use employs a Gaussian shaped profile with a semi-empirical asymmetry correction for low-angle peaks. The integrated intensity is taken to be proportional to the classical Lorentz factor calculated for the X-ray case. In this paper an exact expression is given for the peak profile based upon the geometrical dimensions of the diffractometer. It is shown that the asymmetry of observed peaks is well reproduced by this expression. The angular displacement of the experimental profile with respect to the nominal Bragg angle value is larger than expected. Values for the correction to the classical Lorentz factor for the integrated intensity are given. The exact peak profile expression has been incorporated into a Rietveld profile analysis refinement program. (Auth.)

  11. Reduced exercise capacity in untreated adults with primary growth hormone resistance (Laron syndrome).

    Science.gov (United States)

    Ben-Dov, Issahar; Gaides, Mark; Scheinowitz, Mickey; Wagner, Rivka; Laron, Zvi

    2003-12-01

    Primary IGF-I deficiency (Laron syndrome, LS) may decrease exercise capacity as a result of a lack of an IGF-I effect on heart, peripheral muscle or lung structure and/or function. Eight patients (six females) who had never received treatment with IGF-I, with mean age of 36 +/- 10 (SD) years (range 21-48), weight 47 +/- 9 kg (31-61), height 126 +/- 12 cm (112-140) and body mass index of 29 +/- 4 kg/m2 (24-34), and 12 age-matched controls, underwent lung function tests and incremental cycling to the limit of tolerance (CPX, MedGraphics). Predicted values for the patients were derived from adult equations based on height. In LS patients, lung function was near normal; vital capacity was 84 +/- 11% of expected (66-103). Peak exercise O2-uptake and the anaerobic threshold were reduced, 57 +/- 20% of predicted and 33 +/- 9% of predicted peak (P = 0.005 vs. controls), despite normal mean exercise breathing reserve. All parameters were normal in the controls. Exercise capacity in untreated adults with LS is significantly reduced. The limitation for most patients was not ventilatory but resulted either from low cardiac output and/or from dysfunction of the peripheral muscles. However, the relative contribution of each of these elements and/or the role of poor fitness needs further study.

  12. Improving the peak power density estimation for the DNBR trip signal

    International Nuclear Information System (INIS)

    Moreira, Joao M. L.; Souza, Rose Mary G.P.

    2002-01-01

    The departure from nucleate boiling (DNB) core protection in PWR reactors is usually carried out through the over temperature trip or the instantaneous minimum DNB ratio (DNBR) trip. The protection is obtained through specialized correlations or fast digital computer simulators that infer the core power level, and local coolant thermal and flow conditions out of process variables furnished by the instrumentation. The power density distribution information is usually expressed in terms of F q , the power peak factor, and its location. F q , in its turn, can be determined through the control rod position or, more often, through the power axial offset (AO) F q =f (AO, control rod positions). The AO, defined as the difference between upper and lower long ion chambers signals, is supplied for each channel by separate sets of out-of-core detectors positioned 90 or 120 degrees apart in plan. The AO is given by AO=(S t -S b )/(S t +S b ) where S t and S b are the out-of-core signals from the top and the bottom sections, respectively. In current PWRs a large penalty is imposed to the result of the first equation, because of the difficult of inferring with good accuracy the peak factor from the AO obtained from the out-of-core instrumentation. This ends up reducing the plant capacity factor. In this work, the f function in the first equation, which correlates the power peak factor with the axial offset yielded by out-of-core detectors and control rod positions, is obtained through a combination of specific experiments in the IPEN/MB-01 zero-power reactor and calculation results. For improving the peak factor estimation, it is necessary to consider accurately the response of the out-of-core detectors to different power density distribution in the core. This task is not easily accomplished through calculation due to the difficulties involved in the necessary neutron transport treatment for the out-of-core detector responses

  13. Pulmonary hypertension in patients with idiopathic pulmonary fibrosis - the predictive value of exercise capacity and gas exchange efficiency.

    Directory of Open Access Journals (Sweden)

    Sven Gläser

    Full Text Available Exercise capacity and survival of patients with IPF is potentially impaired by pulmonary hypertension. This study aims to investigate diagnostic and prognostic properties of gas exchange during exercise and lung function in IPF patients with or without pulmonary hypertension. In a multicentre setting, patients with IPF underwent right heart catheterization, cardiopulmonary exercise and lung function testing during their initial evaluation. Mortality follow up was evaluated. Seventy-three of 135 patients [82 males; median age of 64 (56; 72 years] with IPF had pulmonary hypertension as assessed by right heart catheterization [median mean pulmonary arterial pressure 34 (27; 43 mmHg]. The presence of pulmonary hypertension was best predicted by gas exchange efficiency for carbon dioxide (cut off ≥152% predicted; area under the curve 0.94 and peak oxygen uptake (≤56% predicted; 0.83, followed by diffusing capacity. Resting lung volumes did not predict pulmonary hypertension. Survival was best predicted by the presence of pulmonary hypertension, followed by peak oxygen uptake [HR 0.96 (0.93; 0.98]. Pulmonary hypertension in IPF patients is best predicted by gas exchange efficiency during exercise and peak oxygen uptake. In addition to invasively measured pulmonary arterial pressure, oxygen uptake at peak exercise predicts survival in this patient population.

  14. Method and apparatus for current-output peak detection

    Science.gov (United States)

    De Geronimo, Gianluigi

    2017-01-24

    A method and apparatus for a current-output peak detector. A current-output peak detector circuit is disclosed and works in two phases. The peak detector circuit includes switches to switch the peak detector circuit from the first phase to the second phase upon detection of the peak voltage of an input voltage signal. The peak detector generates a current output with a high degree of accuracy in the second phase.

  15. Gamma-Ray Peak Integration: Accuracy and Precision

    International Nuclear Information System (INIS)

    Richard M. Lindstrom

    2000-01-01

    The accuracy of singlet gamma-ray peak areas obtained by a peak analysis program is immaterial. If the same algorithm is used for sample measurement as for calibration and if the peak shapes are similar, then biases in the integration method cancel. Reproducibility is the only important issue. Even the uncertainty of the areas computed by the program is trivial because the true standard uncertainty can be experimentally assessed by repeated measurements of the same source. Reproducible peak integration was important in a recent standard reference material certification task. The primary tool used for spectrum analysis was SUM, a National Institute of Standards and Technology interactive program to sum peaks and subtract a linear background, using the same channels to integrate all 20 spectra. For comparison, this work examines other peak integration programs. Unlike some published comparisons of peak performance in which synthetic spectra were used, this experiment used spectra collected for a real (though exacting) analytical project, analyzed by conventional software used in routine ways. Because both components of the 559- to 564-keV doublet are from 76 As, they were integrated together with SUM. The other programs, however, deconvoluted the peaks. A sensitive test of the fitting algorithm is the ratio of reported peak areas. In almost all the cases, this ratio was much more variable than expected from the reported uncertainties reported by the program. Other comparisons to be reported indicate that peak integration is still an imperfect tool in the analysis of gamma-ray spectra

  16. Yacht type and crew-specific differences in anthropometric, aerobic capacity, and muscle strength parameters among international Olympic class sailors.

    Science.gov (United States)

    Bojsen-Møller, Jens; Larsson, Benny; Magnusson, S Peter; Aagaard, Per

    2007-08-01

    Physical fitness and muscular strength are important performance factors for Olympic class sailors, but the physical demands vary greatly between yacht classes, and limited information is available regarding the physical demands for the different crew positions. In the present paper, strength and aerobic capacity data from elite Olympic sailors are presented and compared with previous findings. Furthermore, a system for classification of Olympic class sailors is suggested. Peak aerobic capacity (peak oxygen uptake, VO(2peak)) and maximal isometric and isokinetic muscle strength of the knee extensors and flexors were assessed, together with the hamstring/quadriceps strength ratio (H/Q ratio). Peak aerobic capacity (ml O(2) . min(-1) . kg(-2/3)) was as follows: males - static hikers (n = 5) 215, s = 7; dynamic hikers (n = 8) 252, s = 17; trapezing helmsmen (n = 6) 234, s = 15; trapezing crew (n = 10) 239, s = 16; females - dynamic hikers (n = 6) 194, s = 16; trapezing crew (n = 2) 200, s = 13. Strength data for hikers, presented as peak moments (normalized to body weight) obtained during eccentric, isometric, and concentric contraction (Nm . kg(-1)) respectively were as follows: males - quadriceps: 3.66 (s = 0.68), 3.97 (s = 0.66), 1.82 (s = 0.34); hamstrings: 1.93 (s = 0.22), 1.38 (s = 0.41), 1.05 (s = 0.21); females - quadriceps: 3.84 (s = 0.71), 3.81 (s = 0.58), 1.60 (s = 0.28); hamstrings: 1.75 (s = 0.23), 1.10 (s = 0.16), 0.84 (s = 0.13). The peak moment based H/Q ratios for slow eccentric and concentric contractions were 0.42 (s = 0.11) and 0.39 (s = 0.04) for males and 0.43 (s = 0.06) and 0.39 (s = 0.04) for females respectively. Elite Olympic class sailors demonstrated high VO(2peak) values comparable to those observed in other non-endurance sports. The strength data revealed very high quadriceps strength for hikers, which is likely a result of the high muscle forces encountered during sailing, and a low H/Q ratio. To ensure optimal knee joint stabilization

  17. BODY BUILD AND BODY COMPOSITION VS. PHYSICAL CAPACITY IN YOUNG JUDO CONTESTANTS COMPARED TO UNTRAINED SUBJECTS

    Directory of Open Access Journals (Sweden)

    G. Lech

    2011-11-01

    Full Text Available The aim of the present study was to (1 find differences in body build and aerobic and anaerobic capacity between young judoists and untrained peers; (2 compare correlations for indicators of body build with indicators of aerobic and anaerobic capacity among the group of trained and untrained subjects. The study group comprised 18 subjects selected during a competitive period, who had taken at least fifth place in national judo tournaments. Their training experience ranged from 6 to 11 years, 8 to 10 hours a week. The control group was composed of 18 untrained students from one of the schools included in the study. Their body height and mass (BM did not differ compared to judoists. A body composition chart was employed for analysis of body build and body composition. Physiological investigations encompassed measurements of anaerobic (Wingate test and aerobic (graded exercise test on cycle ergometer capacity. Judo contestants are typically characterized by higher BMI, fat-free mass and fat-free mass index compared to the untrained. Compared to the group of untrained peers, young athletes in this sport are distinguished by the time needed to generate peak power. This difference is not observed in the indices characterising aerobic capacity. The level of the indices of body build and composition in young judo contestants shows a moderate and strong correlation with indices of anaerobic and aerobic capacity. The amount of total work in the Wingate test was positively correlated with BMI (r=0.65, p<0.01, fat-free mass index (r=0.63, p<0.01, body mass (r=0.49, p<0.05, fat mass index (r=0.49, p<0.05 and percentage of fat (r=0.48, p<0.05. Maximal peak anaerobic power was positively correlated with fat-free mass index (r=0.48, p<0.05 and percentage of fat (r=0.50, p<0.05. A strong negative correlation between ·VO2max with body mass (r=-0.75, p<0.001, BMI (r=-0.72, p<0.001, moderate correlation with PF%(r=-0.64, p<0.01, fat-free mass index (r=-0.52, p<0

  18. Dietary antioxidant capacity and risk of type 2 diabetes in the large prospective E3N-EPIC cohort.

    Science.gov (United States)

    Mancini, Francesca Romana; Affret, Aurélie; Dow, Courtney; Balkau, Beverley; Bonnet, Fabrice; Boutron-Ruault, Marie-Christine; Fagherazzi, Guy

    2018-02-01

    Recent evidence suggests that oxidative stress may contribute to the pathogenesis of type 2 diabetes. The diet, and especially fruit and vegetables, contains a variety of compounds with antioxidant activity, which may have cumulative/synergistic antioxidant effects. The total antioxidant capacity, an index derived from dietary intake, is a single estimate of antioxidant capacity from all dietary antioxidants. The main aim of this study was to investigate the relationship between total antioxidant capacity and risk of type 2 diabetes. Among 64,223 women (mean age 52 ± 7 years) from the French E3N-European Prospective Investigation into Cancer and Nutrition (EPIC) cohort, 1751 women had validated type 2 diabetes during 15 years of follow-up. The total antioxidant capacity was estimated with the ferric ion-reducing antioxidant power (FRAP) method. Adjusted Cox proportional hazards regression models were used to calculate HRs and 95% CIs for the associations between total antioxidant capacity and type 2 diabetes risk, adjusted for potential confounders. In multivariable models, higher levels of total antioxidant capacity were associated with a lower risk of type 2 diabetes. Compared with women in the lowest quintile, women in the third, fourth and fifth quintiles for total antioxidant capacity had HRs of 0.74 (95% CI 0.63, 0.86), 0.70 (95% CI 0.59, 0.83) and 0.73 (95% CI 0.60, 0.89), respectively. The inverse association between total antioxidant capacity and risk of type 2 diabetes was linear up to values of 15 mmol/day, after which the effect reached a plateau. Our findings suggest that the total antioxidant capacity may play an important role in reducing the risk of type 2 diabetes in middle-aged women. More studies are warranted to better understand the biological mechanisms underlying this inverse association.

  19. Effects of diffusion on total biomass in heterogeneous continuous and discrete-patch systems

    Science.gov (United States)

    DeAngelis, Donald L.; Ming Ni, Wei; Zhang, Bo

    2016-01-01

    Theoretical models of populations on a system of two connected patches previously have shown that when the two patches differ in maximum growth rate and carrying capacity, and in the limit of high diffusion, conditions exist for which the total population size at equilibrium exceeds that of the ideal free distribution, which predicts that the total population would equal the total carrying capacity of the two patches. However, this result has only been shown for the Pearl-Verhulst growth function on two patches and for a single-parameter growth function in continuous space. Here, we provide a general criterion for total population size to exceed total carrying capacity for three commonly used population growth rates for both heterogeneous continuous and multi-patch heterogeneous landscapes with high population diffusion. We show that a sufficient condition for this situation is that there is a convex positive relationship between the maximum growth rate and the parameter that, by itself or together with the maximum growth rate, determines the carrying capacity, as both vary across a spatial region. This relationship occurs in some biological populations, though not in others, so the result has ecological implications.

  20. Antioxidant capacity of fresh and stored breast milk: is -80°C optimal temperature for freeze storage?

    Science.gov (United States)

    Sari, Fatma Nur; Akdag, Arzu; Dizdar, Evrim Alyamac; Uras, Nurdan; Erdeve, Omer; Erel, Ozcan; Dilmen, Ugur

    2012-06-01

    To determine total antioxidant capacity and total oxidation status in fresh and freeze stored (at -80°C) breast milk during the stages of lactation. Samples of colostrum, transitional and mature milk were collected from 44 healthy women at 3, 8 and 30 days after birth. The total milk volume collected (6 ml) was divided in two aliquot parts: 3 ml for the fresh analysis which was done immediately after the extraction and 3 ml for storage under freezing conditions at -80°C for two months. The antioxidant status and oxidative stress of the fresh and stored breast milk were assessed via determination of total antioxidant capacity and total oxidation status. Antioxidant capacity of transitional and mature milk decreased (p = 0.0001, p = 0.028, respectively); however, antioxidant capacity of colostrum did not change by storage at -80°C (p > 0.05). Total antioxidant capacity of fresh and stored breast milk significantly decreased during the stages of lactation (p Total oxidation status showed no significant difference in fresh and stored breast milk during the stages of lactation (p > 0.05). Freeze storage of breast milk at -80°C for two months seems not to be the optimal condition to preserve the antioxidant capacity of breast milk.

  1. Relationships between electroencephalographic spectral peaks across frequency bands

    Directory of Open Access Journals (Sweden)

    Sacha Jennifer Van Albada

    2013-03-01

    Full Text Available The degree to which electroenencephalographic (EEG spectral peaks are independent, and the relationships between their frequencies have been debated. A novel fitting method was used to determine peak parameters in the range 2–35 Hz from a large sample of eyes-closed spectra, and their interrelationships were investigated. Findings were compared with a mean-field model of thalamocortical activity, which predicts near-harmonic relationships between peaks. The subject set consisted of 1424 healthy subjects from the Brain Resource International Database. Peaks in the theta range occurred on average near half the alpha peak frequency, while peaks in the beta range tended to occur near twice and three times the alpha peak frequency on an individual-subject basis. Moreover, for the majority of subjects, alpha peak frequencies were significantly positively correlated with frequencies of peaks in the theta and low and high beta ranges. Such a harmonic progression agrees semiquantitatively with theoretical predictions from the mean-field model. These findings indicate a common or analogous source for different rhythms, and help to define appropriate individual frequency bands for peak identification.

  2. Relationships between Electroencephalographic Spectral Peaks Across Frequency Bands

    Science.gov (United States)

    van Albada, S. J.; Robinson, P. A.

    2013-01-01

    The degree to which electroencephalographic spectral peaks are independent, and the relationships between their frequencies have been debated. A novel fitting method was used to determine peak parameters in the range 2–35 Hz from a large sample of eyes-closed spectra, and their interrelationships were investigated. Findings were compared with a mean-field model of thalamocortical activity, which predicts near-harmonic relationships between peaks. The subject set consisted of 1424 healthy subjects from the Brain Resource International Database. Peaks in the theta range occurred on average near half the alpha peak frequency, while peaks in the beta range tended to occur near twice and three times the alpha peak frequency on an individual-subject basis. Moreover, for the majority of subjects, alpha peak frequencies were significantly positively correlated with frequencies of peaks in the theta and low and high beta ranges. Such a harmonic progression agrees semiquantitatively with theoretical predictions from the mean-field model. These findings indicate a common or analogous source for different rhythms, and help to define appropriate individual frequency bands for peak identification. PMID:23483663

  3. The geomorphic structure of the runoff peak

    Directory of Open Access Journals (Sweden)

    R. Rigon

    2011-06-01

    Full Text Available This paper develops a theoretical framework to investigate the core dependence of peak flows on the geomorphic properties of river basins. Based on the theory of transport by travel times, and simple hydrodynamic characterization of floods, this new framework invokes the linearity and invariance of the hydrologic response to provide analytical and semi-analytical expressions for peak flow, time to peak, and area contributing to the peak runoff. These results are obtained for the case of constant-intensity hyetograph using the Intensity-Duration-Frequency (IDF curves to estimate extreme flow values as a function of the rainfall return period. Results show that, with constant-intensity hyetographs, the time-to-peak is greater than rainfall duration and usually shorter than the basin concentration time. Moreover, the critical storm duration is shown to be independent of rainfall return period as well as the area contributing to the flow peak. The same results are found when the effects of hydrodynamic dispersion are accounted for. Further, it is shown that, when the effects of hydrodynamic dispersion are negligible, the basin area contributing to the peak discharge does not depend on the channel velocity, but is a geomorphic propriety of the basin. As an example this framework is applied to three watersheds. In particular, the runoff peak, the critical rainfall durations and the time to peak are calculated for all links within a network to assess how they increase with basin area.

  4. Temporal precision and the capacity of auditory-verbal short-term memory.

    Science.gov (United States)

    Gilbert, Rebecca A; Hitch, Graham J; Hartley, Tom

    2017-12-01

    The capacity of serially ordered auditory-verbal short-term memory (AVSTM) is sensitive to the timing of the material to be stored, and both temporal processing and AVSTM capacity are implicated in the development of language. We developed a novel "rehearsal-probe" task to investigate the relationship between temporal precision and the capacity to remember serial order. Participants listened to a sub-span sequence of spoken digits and silently rehearsed the items and their timing during an unfilled retention interval. After an unpredictable delay, a tone prompted report of the item being rehearsed at that moment. An initial experiment showed cyclic distributions of item responses over time, with peaks preserving serial order and broad, overlapping tails. The spread of the response distributions increased with additional memory load and correlated negatively with participants' auditory digit spans. A second study replicated the negative correlation and demonstrated its specificity to AVSTM by controlling for differences in visuo-spatial STM and nonverbal IQ. The results are consistent with the idea that a common resource underpins both the temporal precision and capacity of AVSTM. The rehearsal-probe task may provide a valuable tool for investigating links between temporal processing and AVSTM capacity in the context of speech and language abilities.

  5. Dietary Polyphenol Intake, but Not the Dietary Total Antioxidant Capacity, Is Inversely Related to Cardiovascular Disease in Postmenopausal Polish Women: Results of WOBASZ and WOBASZ II Studies

    Directory of Open Access Journals (Sweden)

    Anna M. Witkowska

    2017-01-01

    Full Text Available The aim of the study was to assess the relationship between the dietary polyphenol intake (DPI and the dietary total antioxidant capacity (DTAC and the prevalence of cardiovascular disease (CVD in postmenopausal women. Participants were 916 postmenopausal women diagnosed with CVD and 1683 postmenopausal women without history of CVD, who took part in the population-based studies carried out in Poland: WOBASZ (2003–2005 and WOBASZ II (2013-2014. Nutritional data were collected using a single 24-hour dietary recall. DPI and DTAC in the CVD women were significantly lower and accounted for 1766.39 mg/d and 10.84 mmol/d, respectively, versus 1920.57 mg/d and 11.85 mmol/d in the women without CVD, but these differences disappeared after the standardization for energy input. Also, in the multiple-adjustment model, higher DPI, but not DTAC, was associated with the reduced odds ratio for the prevalence of CVD. Beverages, mainly coffee and tea, contributed in more than 40% to DPI and in more than a half to DTAC. In this study, higher dietary polyphenol intake, but not the dietary total antioxidant capacity, was inversely associated with CVD in postmenopausal women, which points to the health benefits of increased polyphenol intake from food sources for these women.

  6. On the Capacity of FSO Links over Gamma-Gamma Atmospheric Turbulence Channels Using OOK Signaling

    Directory of Open Access Journals (Sweden)

    Antonio García-Zambrana

    2010-01-01

    Full Text Available A new upper bound on the capacity of power- and bandwidth-constrained optical wireless links over gamma-gamma atmospheric turbulence channels with intensity modulation and direct detection is derived when on-off keying (OOK formats are used. In this free-space optical (FSO scenario, unlike previous capacity bounds derived from the classic capacity of the well-known additive white Gaussian noise (AWGN channel with uniform input distribution, a new closed-form upper bound on the capacity is found by bounding the mutual information subject to an average optical power constraint and not only to an average electrical power constraint, showing the fact that the input distribution that maximizes the mutual information varies with the turbulence strength and the signal-to-noise ratio (SNR. Additionally, it is shown that an increase of the peak-to-average optical power ratio (PAOPR provides higher capacity values. Simulation results for the mutual information are further demonstrated to confirm the analytical results under several turbulence conditions.

  7. The effect of habitual waterpipe tobacco smoking on pulmonary function and exercise capacity in young healthy males: A pilot study.

    Science.gov (United States)

    Hawari, F I; Obeidat, N A; Ghonimat, I M; Ayub, H S; Dawahreh, S S

    2017-01-01

    Evidence regarding the health effects of habitual waterpipe smoking is limited, particularly in young smokers. Respiratory health and cardiopulmonary exercise tests were compared in young male habitual waterpipe smokers (WPS) versus non-smokers. 69 WPS (≥3 times/week for three years) and 69 non-smokers were studied. Respiratory health was assessed through the American Thoracic Society and the Division of Lung Diseases (ATS-DLD-78) adult questionnaire. Pulmonary function and cardiopulmonary exercise tests were performed. Self-reported respiratory symptoms, forced expiratory volume in first second (FEV 1 ), forced vital capacity (FVC), FEV 1 /FVC ratio, forced expiratory flow between 25 and 75% of FVC (FEF 25-75% ), peak expiratory flow (PEF), exercise time, peak end-tidal CO 2 tension (PetCO 2 ), subject-reported leg fatigue and dyspnea; peak O 2 uptake (VO 2 max), and end-expiratory lung volume (EELV) change from baseline (at peak exercise) were measured. WPS were more likely than non-smokers to report respiratory symptoms. WPS also demonstrated: shorter exercise time; lower peak VO 2 ; higher perceived dyspnea at mid-exercise; lower values of the following: FEV 1 , FVC, PEF, and EELV change. Habitual waterpipe tobacco smoking in young seemingly healthy individuals is associated with a greater burden of respiratory symptoms and impaired exercise capacity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Right ventricular outflow tract systolic function correlates with exercise capacity in patients with severe right ventricle dilatation after repair of tetralogy of Fallot.

    Science.gov (United States)

    Luo, Shuhua; Li, Jianhua; Yang, Dan; Zhou, Yaxin; An, Qi; Chen, Yucheng

    2017-05-01

    The relationship between exercise capacity and right ventricular (RV) components function in repaired tetralogy of Fallot patients with severely dilated right ventricles is poorly understood. The aim of this study was to characterize the exercise capacity and its relationship to RV global and components function in repaired tetralogy of Fallot patients with RV end-diastolic volume index  >150 ml/m 2 , a currently accepted threshold for pulmonary valve replacement. The medical records and results of cardiac magnetic resonance imaging and cardiopulmonary exercise testing of 25 consecutive eligible patients were reviewed. Twenty age- and gender-matched normal subjects were enrolled as cardiac magnetic resonance control. End-diastolic, end-systolic and stroke volumes, and ejection fraction (EF) were determined for the total RV and its components. Of the 25 patients, 44% maintained normal exercise capacity. RV outlet EF was higher ( P  = 0.02) and RV incisions smaller ( P  = 0.04) in patients with normal exercise capacity than those with subnormal exercise capacity. Predicted peak oxygen consumption correlated better with the RV outflow tract EF than with the EF of other components of the RV or the global EF ( r  = 0.59; P  = 0.002). Multivariate analysis showed the RV outflow tract EF to be the only independent predictor of exercise capacity (ß = 0.442; P  = 0.02). Exercise capacity is preserved in some tetralogy of Fallot patients with severe RV dilatation. RV outflow tract EF is independently associated with exercise capacity in such patients, and could be a reliable determinant of intrinsic RV performance. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. On the Capacity of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas

    2016-01-12

    The capacity of the intensity-modulation directdetection optical broadcast channel (OBC) is investigated, under both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans’ approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian (TG) distributions or discrete distributions. While the discrete distribution achieves higher rates, the TG distribution leads to a simpler representation of the achievable rate region. At high signal-to-noise ratio (SNR), it is shown that the TG distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows. It also achieves the capacity region within a constant gap. At low SNR, it is shown that on-off keying (OOK) with time-division multipleaccess (TDMA) is optimal. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves fairly good performance.

  10. On the Capacity of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2016-01-01

    The capacity of the intensity-modulation directdetection optical broadcast channel (OBC) is investigated, under both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans’ approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian (TG) distributions or discrete distributions. While the discrete distribution achieves higher rates, the TG distribution leads to a simpler representation of the achievable rate region. At high signal-to-noise ratio (SNR), it is shown that the TG distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows. It also achieves the capacity region within a constant gap. At low SNR, it is shown that on-off keying (OOK) with time-division multipleaccess (TDMA) is optimal. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves fairly good performance.

  11. Phytosterol supplementation does not affect plasma antioxidant capacity in patients with metabolic syndrome.

    Science.gov (United States)

    Sialvera, Theodora-Eirini; Koutelidakis, Antonios E; Richter, Dimitris J; Yfanti, Georgia; Kapsokefalou, Maria; Micha, Renata; Goumas, Giorgos; Diamantopoulos, Emmanouil; Zampelas, Antonis

    2013-02-01

    Several studies have observed decreased levels of lipophilic antioxidants after supplementation with phytosterols and stanols. The aim of this study was to examine the effect of phytosterol supplementation on plasma total antioxidant capacity in patients with metabolic syndrome. In a parallel arm, randomized placebo-controlled design, 108 patients with metabolic syndrome were assigned to consume yogurt beverage which provided 4 g of phytosterols per day or yogurt beverage without phytosterols. The duration of the study was 2 months and the patients in both groups followed their habitual westernized type diet. Blood samples were drawn at baseline and after 2 months, and the total antioxidant capacity of plasma was measured using the ferric reducing antioxidant power of plasma and oxygen radical absorbance capacity assays. After 2 months of intervention, plasma total antioxidant capacity did not differ between and within the intervention and the control groups. Phytosterol supplementation does not affect plasma antioxidant status.

  12. Theoretical Investigation of Peak-Delay Force Reduction for Caissons Exposed to Non-breaking Short-Crested Waves

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Z.

    In nature coastal structures are exposed to oblique short-crested waves. The effect of wave incident angle on total wave force on a long caisson are twofold. The one is the force reduction due to the reduction of instantaneous point pressure on the caisson, named point-pressure force reduction....... The other is the force reduction due to the fact that the peak pressures do not occur simultaneously along the caisson, named peak-delay force reduction. These two reduction effects can also be expected with short-crested waves, as the short-crestedness of waves means the spreading of wave energy over...... a range of incident angles. The peak-delay force reduction, i.e. no simultaneous peak along caisson, is of particular interest because the equipment improvement in construction enables the building of considerably long caissons. In Japan length of caissons exceeds often 100m. This paper will concentrate...

  13. Phenolics content and antioxidant capacity of commercial red fruit juices

    Directory of Open Access Journals (Sweden)

    Mitić Milan N.

    2011-01-01

    Full Text Available The content of phenolics: total phenols (TP, flavonoids (TF, anthocyanins (TA and hydroxicinnamic acid as well as the total antioxidant capacity (TAC in nine commercial red fruit juices (sour cherry, black currant, red grape produced in Serbia were evaluated. The total compounds content was measured by spectrophotometric methods, TAC was determined using DPPH assays, and individual anthocyanins and hydroxycinnamic acids was determined using HPLC-DAD methods. Among the examined fruit juices, the black currant juices contained the highest amounts of all groups of the phenolics and exhibited strong antioxidant capacity. The amount of anthocyanins determined by HPLC method ranged from 92.36 to 512.73 mg/L in red grape and black currant juices, respectively. The anthocyanins present in the investigated red fruit juices were derivatives of cyanidin, delphinidin, petunidin, peonidin and malvidin. The predominant phenolic acid was neoclorogenic acid in sour cherry, caffeic acid in black currant, and p-coumaric acid in black grape juices. Generally, the red fruit juices produced in the Serbia are a rich source of the phenolic, which show evident antioxidant capacity.

  14. Capacity limits of spectrum-sharing systems over hyper-fading channels

    KAUST Repository

    Ekin, Sabit

    2011-01-20

    Cognitive radio (CR) with spectrum-sharing feature is a promising technique to address the spectrum under-utilization problem in dynamically changing environments. In this paper, the achievable capacity gain of spectrum-sharing systems over dynamic fading environments is studied. To perform a general analysis, a theoretical fading model called hyper-fading model that is suitable to the dynamic nature of CR channel is proposed. Closed-form expressions of probability density function (PDF) and cumulative density function (CDF) of the signal-to-noise ratio (SNR) for secondary users (SUs) in spectrum-sharing systems are derived. In addition, the capacity gains achievable with spectrum-sharing systems in high and low power regions are obtained. The effects of different fading figures, average fading powers, interference temperatures, peak powers of secondary transmitters, and numbers of SUs on the achievable capacity are investigated. The analytical and simulation results show that the fading figure of the channel between SUs and primary base-station (PBS), which describes the diversity of the channel, does not contribute significantly to the system performance gain. © 2011 John Wiley & Sons, Ltd.

  15. Capacity limits of spectrum-sharing systems over hyper-fading channels

    KAUST Repository

    Ekin, Sabit; Yilmaz, Ferkan; Ç elebi, Hasari Burak; Qaraqe, Khalid A.; Alouini, Mohamed-Slim; Serpedin, Erchin

    2011-01-01

    Cognitive radio (CR) with spectrum-sharing feature is a promising technique to address the spectrum under-utilization problem in dynamically changing environments. In this paper, the achievable capacity gain of spectrum-sharing systems over dynamic fading environments is studied. To perform a general analysis, a theoretical fading model called hyper-fading model that is suitable to the dynamic nature of CR channel is proposed. Closed-form expressions of probability density function (PDF) and cumulative density function (CDF) of the signal-to-noise ratio (SNR) for secondary users (SUs) in spectrum-sharing systems are derived. In addition, the capacity gains achievable with spectrum-sharing systems in high and low power regions are obtained. The effects of different fading figures, average fading powers, interference temperatures, peak powers of secondary transmitters, and numbers of SUs on the achievable capacity are investigated. The analytical and simulation results show that the fading figure of the channel between SUs and primary base-station (PBS), which describes the diversity of the channel, does not contribute significantly to the system performance gain. © 2011 John Wiley & Sons, Ltd.

  16. Passive radio frequency peak power multiplier

    Science.gov (United States)

    Farkas, Zoltan D.; Wilson, Perry B.

    1977-01-01

    Peak power multiplication of a radio frequency source by simultaneous charging of two high-Q resonant microwave cavities by applying the source output through a directional coupler to the cavities and then reversing the phase of the source power to the coupler, thereby permitting the power in the cavities to simultaneously discharge through the coupler to the load in combination with power from the source to apply a peak power to the load that is a multiplication of the source peak power.

  17. Peak load arrangements : Assessment of Nordel guidelines

    Energy Technology Data Exchange (ETDEWEB)

    2009-07-01

    Two Nordic countries, Sweden and Finland, have legislation that empowers the TSO to acquire designated peak load resources to mitigate the risk for shortage situations during the winter. In Denmark, the system operator procures resources to maintain a satisfactory level of security of supply. In Norway the TSO has set up a Regulation Power Option Market (RKOM) to secure a satisfactory level of operational reserves at all times, also in winter with high load demand. Only the arrangements in Finland and Sweden fall under the heading of Peak Load Arrangements defined in Nordel Guidelines. NordREG has been invited by the Electricity Market Group (EMG) to evaluate Nordel's proposal for 'Guidelines for transitional Peak Load Arrangements'. The EMG has also financed a study made by EC Group to support NordREG in the evaluation of the proposal. The study has been taken into account in NordREG's evaluation. In parallel to the EMG task, the Swedish regulator, the Energy Markets Inspectorate, has been given the task by the Swedish government to investigate a long term solution of the peak load issue. The Swedish and Finnish TSOs have together with Nord Pool Spot worked on finding a harmonized solution for activation of the peak load reserves in the market. An agreement accepted by the relevant authorities was reached in early January 2009, and the arrangement has been implemented since 19th January 2009. NordREG views that the proposed Nordel guidelines have served as a starting point for the presently agreed procedure. However, NordREG does not see any need to further develop the Nordel guidelines for peak load arrangements. NordREG agrees with Nordel that the market should be designed to solve peak load problems through proper incentives to market players. NordREG presumes that the relevant authorities in each country will take decisions on the need for any peak load arrangement to ensure security of supply. NordREG proposes that such decisions should be

  18. The slope-background for the near-peak regimen of photoemission spectra

    Energy Technology Data Exchange (ETDEWEB)

    Herrera-Gomez, A., E-mail: aherrera@qro.cinvestav.mx [CINVESTAV-Unidad Queretaro, Queretaro 76230 (Mexico); Bravo-Sanchez, M. [CINVESTAV-Unidad Queretaro, Queretaro 76230 (Mexico); Aguirre-Tostado, F.S. [Centro de Investigación en Materiales Avanzados, Chihuahua, Chihuahua 31109 (Mexico); Vazquez-Lepe, M.O. [Departamento de Ingeniería de Proyectos, Universidad de Guadalajara, Jalisco 44430 (Mexico)

    2013-08-15

    Highlights: •We propose a method that accounts for the change in the background slope of XPS data. •The slope-background can be derived from Tougaard–Sigmund's transport theory. •The total background is composed by Shirley–Sherwood and Tougaard type backgrounds. •The slope-background employs one parameter that can be related to REELS spectra. •The slope, in conjunction with the Shirley–Sherwood background, provides better fits. -- Abstract: Photoemission data typically exhibits a change on the intensity of the background between the two sides of the peaks. This step is usually very well reproduced by the Shirley–Sherwood background. Yet, the change on the slope of the background in the near-peak regime, although usually present, is not always as obvious to the eye. However, the intensity of the background signal associated with the evolution of its slope can be appreciable. The slope-background is designed to empirically reproduce the change on the slope. Resembling the non-iterative Shirley method, the proposed functional form relates the slope of the background to the integrated signal at higher electron kinetic energies. This form can be predicted under Tougaard–Sigmund's electron transport theory in the near-peak regime. To reproduce both the step and slope changes on the background, it is necessary to employ the slope-background in conjunction with the Shirley–Sherwood background under the active-background method. As it is shown for a series of materials, the application of the slope-background provides excellent fits, is transparent to the operator, and is much more independent of the fitting range than other background methods. The total area assessed through the combination of the slope and the Shirley–Sherwood backgrounds is larger than when only the Shirley–Sherwood background is employed, and smaller than when the Tougaard background is employed.

  19. Monopolist requires totally liberalization

    International Nuclear Information System (INIS)

    Janoska, J.

    2003-01-01

    Slovenske elektrarne (SE), a.s, Bratislava in present time operates some sources, which would be off at normal conditions. It was caused by high electricity price on European markets. It is possible to sell 1 MWh for 12 thousands Slovak crowns abroad in last months. It is also advantageous to initialise thermal sources for power plant, where variable expenses are higher - from 1200 to 1300 Slovak crowns per MWh. SE are mainly trying to sell most of electricity on domestic market because returnability of dominant nuclear power plants was projected for this market. Utilizing capacities profit via domestic market covers fixed costs of power plants. Besides, power plant can demand regulated price 1272 Slovak crowns per 1 MWh. SE sources have capacity of 6800 MW, but maximal daily load uses for example in December approximately 4000 MW. Overflows are more higher in the summer - load dropped to 2200 MW in the beginning of September in last year. It is noted in issue that price increase in Europe is noticed. Price of primary power electricity will remain at liquid markets at 28 Euro (1176 Slovak crowns) in the following year prices fluctuate from 38 to 40 Euro (to 1700 Slovak crowns) per 1 MW at load peaks. Price increase is caused by lack of sources - it does not keep up to satisfy demand increase. Sources are gradually laid up and no new sources are built. Production capacities will decrease also in SE - by laying up of two 440 MW blocks of Bohunice NPP V-1. Price increase trend will continue according to SE businessmen till it is advantageous to build new source. Present price trend can be accelerated by decision about completing of Mochovce NPP 3-4

  20. Heat capacity and thermal expansion of the itinerant helimagnet MnSi.

    Science.gov (United States)

    Stishov, S M; Petrova, A E; Khasanov, S; Kh Panova, G; Shikov, A A; Lashley, J C; Wu, D; Lograsso, T A

    2008-06-11

    The heat capacity and thermal expansion of a high quality single crystal of MnSi were measured at ambient pressure at zero and high magnetic fields. The calculated magnetic entropy change in the temperature range 0-30 K is less than 0.1R, a low value that emphasizes the itinerant nature of magnetism in MnSi. A linear temperature term dominates the thermal expansion coefficient in the range 30-150 K, which correlates with an enhancement of the linear electronic term in the heat capacity. A surprising similarity among the variations of the heat capacity, thermal expansion coefficient and temperature derivative of the resistivity is observed through the phase transition in MnSi. Specific forms of the heat capacity, thermal expansion coefficient and temperature derivative of resistivity at the phase transition to a helical magnetic state near 29 K are interpreted as the combination of sharp first-order features and broad peaks or shallow valleys of as yet unknown origin. The appearance of these broad satellites probably hints at a frustrated magnetic state slightly above the transition temperature in MnSi.

  1. NOISY WEAK-LENSING CONVERGENCE PEAK STATISTICS NEAR CLUSTERS OF GALAXIES AND BEYOND

    International Nuclear Information System (INIS)

    Fan Zuhui; Shan Huanyuan; Liu Jiayi

    2010-01-01

    , for the isothermal cluster. For the NFW cluster, Δν ∼ 0.8. The existence of noise also causes a location offset for the weak-lensing identified main-cluster-peak with respect to the true center of the cluster. The offset distribution is very broad and extends to R ∼ R c for the isothermal case. For the NFW cluster, it is relatively narrow and peaked at R ∼ 0.2R c . We also analyze NFW clusters of different concentrations. It is found that the more centrally concentrated the mass distribution of a cluster is, the less its weak-lensing signal is affected by noise. Incorporating these important effects and the mass function of NFW dark matter halos, we further present a model calculating the statistical abundances of total convergence peaks, true and false ones, over a large field beyond individual clusters. The results are in good agreement with those from numerical simulations. The model then allows us to probe cosmologies with the convergence peaks directly without the need of expensive follow-up observations to differentiate true and false peaks.

  2. Emissions Scenarios and Fossil-fuel Peaking

    Science.gov (United States)

    Brecha, R.

    2008-12-01

    Intergovernmental Panel on Climate Change (IPCC) emissions scenarios are based on detailed energy system models in which demographics, technology and economics are used to generate projections of future world energy consumption, and therefore, of greenhouse gas emissions. Built into the assumptions for these scenarios are estimates for ultimately recoverable resources of various fossil fuels. There is a growing chorus of critics who believe that the true extent of recoverable fossil resources is much smaller than the amounts taken as a baseline for the IPCC scenarios. In a climate optimist camp are those who contend that "peak oil" will lead to a switch to renewable energy sources, while others point out that high prices for oil caused by supply limitations could very well lead to a transition to liquid fuels that actually increase total carbon emissions. We examine a third scenario in which high energy prices, which are correlated with increasing infrastructure, exploration and development costs, conspire to limit the potential for making a switch to coal or natural gas for liquid fuels. In addition, the same increasing costs limit the potential for expansion of tar sand and shale oil recovery. In our qualitative model of the energy system, backed by data from short- and medium-term trends, we have a useful way to gain a sense of potential carbon emission bounds. A bound for 21st century emissions is investigated based on two assumptions: first, that extractable fossil-fuel resources follow the trends assumed by "peak oil" adherents, and second, that little is done in the way of climate mitigation policies. If resources, and perhaps more importantly, extraction rates, of fossil fuels are limited compared to assumptions in the emissions scenarios, a situation can arise in which emissions are supply-driven. However, we show that even in this "peak fossil-fuel" limit, carbon emissions are high enough to surpass 550 ppm or 2°C climate protection guardrails. Some

  3. The water holding capacity of bark in Danish angiosperm trees

    DEFF Research Database (Denmark)

    Larsen, Hanne Marie Ellegård; Rasmussen, Hanne Nina; Nord-Larsen, Thomas

    The water holding capacity of bark in seven Danish angiosperm trees was examined. The aim of the study was (1) to examine height trends and (2) bark thickness trends in relation to the water holding capacity and (3) to determine interspecific differences. The wet-weight and dry-weight of a total...... number of 427 bark samples were measured. The water holding capacity was calculated as the difference between wet-weight and dry-weight per wet-weight. The water holding capacity increased with elevation in most tree species and contrary to the expectation, thinner bark generally had a higher water...... holding capacity. Differences in the water holding capacity of bark may influence the occurrence and distribution of a wide range of bark-living organisms including the distribution of corticolous lichens....

  4. Impact of roof integrated PV orientation on the residential electricity peak demand

    International Nuclear Information System (INIS)

    Sadineni, Suresh B.; Atallah, Fady; Boehm, Robert F.

    2012-01-01

    ) orientations are economically optimal for homes enrolled to flat electricity pricing schedule and time of use pricing respectively. As predicted by the simulations, the energy efficiency methods in the home have decreased the total annual energy by 38% compared to a code standard home of the same size. Further, the energy efficiency methods in the building coupled with a 220° oriented PV and 1.1 °C increase in thermostat temperature for three hours (from 3:00 to 6:00 PM) reduced the peak energy demand by 62% compared to a code standard building of the same size. Battery storage is the other option that will be considered in the project at a later time which is expected to carry the project well beyond its peak reduction goals.

  5. Effects of the Nordic Hamstring exercise on sprint capacity in male football players: a randomized controlled trial.

    Science.gov (United States)

    Ishøi, Lasse; Hölmich, Per; Aagaard, Per; Thorborg, Kristian; Bandholm, Thomas; Serner, Andreas

    2018-07-01

    This assessor-blinded, randomized controlled superiority trial investigated the efficacy of the 10-week Nordic Hamstring exercise (NHE) protocol on sprint performance in football players. Thirty-five amateur male players (age: 17-26 years) were randomized to a do-as-usual control group (CG; n = 17) or to 10-weeks of supervised strength training using the NHE in-season (IG; n = 18). A repeated-sprint test, consisting of 4 × 6 10 m sprints, with 15 s recovery period between sprints and 180 s between sets, was conducted to evaluate total sprint time as the primary outcome. Secondary outcomes were best 10 m sprint time (10mST) and sprint time during the last sprint (L10mST). Additionally, peak eccentric hamstring strength (ECC-P HS ) and eccentric hamstring strength capacity (ECC-CAP HS ) were measured during the NHE. Ten players were lost to follow-up, thus 25 players were analyzed (CG n = 14; IG n = 11). Between-group differences in mean changes were observed in favor of the IG for sprint performance outcomes; TST (-0.649 s, p = 0.056, d = 0.38), 10mST (-0.047 s, p = 0.005, d = 0.64) and L10mST (-0.052 s, p = 0.094, d = 0.59), and for strength outcomes; ECC-P HS (62.3 N, p = 0.006, d = 0.92), and ECC-CAP HS (951 N, p = 0.005, d = 0.95). In conclusion, the NHE showed small-to-medium improvements in sprint performance and large increases in peak eccentric hamstring strength and capacity. NCT02674919.

  6. Degree of conversion of resin-based materials cured with dual-peak or single-peak LED light-curing units.

    Science.gov (United States)

    Lucey, Siobhan M; Santini, Ario; Roebuck, Elizabeth M

    2015-03-01

    There is a lack of data on polymerization of resin-based materials (RBMs) used in paediatric dentistry, using dual-peak light-emitting diode (LED) light-curing units (LCUs). To evaluate the degree of conversion (DC) of RBMs cured with dual-peak or single-peak LED LCUs. Samples of Vit-l-escence (Ultradent) and Herculite XRV Ultra (Kerr) and fissure sealants Delton Clear and Delton Opaque (Dentsply) were prepared (n = 3 per group) and cured with either one of two dual-peak LCUs (bluephase(®) G2; Ivoclar Vivadent or Valo; Ultradent) or a single-peak (bluephase(®) ; Ivoclar Vivadent). High-performance liquid chromatography and nuclear magnetic resonance spectroscopy were used to confirm the presence or absence of initiators other than camphorquinone. The DC was determined using micro-Raman spectroscopy. Data were analysed using general linear model anova; α = 0.05. With Herculite XRV Ultra, the single-peak LCU gave higher DC values than either of the two dual-peak LCUs (P < 0.05). Both fissure sealants showed higher DC compared with the two RBMs (P < 0.05); the DC at the bottom of the clear sealant was greater than the opaque sealant, (P < 0.05). 2,4,6-trimethylbenzoyldiphenylphosphine oxide (Lucirin(®) TPO) was found only in Vit-l-escence. Dual-peak LED LCUs may not be best suited for curing non-Lucirin(®) TPO-containing materials. A clear sealant showed a better cure throughout the material and may be more appropriate than opaque versions in deep fissures. © 2014 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Evaluation of antioxidant capacity of Chinese five-spice ingredients.

    Science.gov (United States)

    Bi, Xinyan; Soong, Yean Yean; Lim, Siang Wee; Henry, Christiani Jeyakumar

    2015-05-01

    Phenolic compounds in spices were reportedly found to possess high antioxidant capacities (AOCs), which may prevent or reduce risk of human diseases such as cardiovascular disease, cancer and diabetes. The potential AOC of Chinese five-spice powder (consist of Szechuan pepper, fennel seed, cinnamon, star anise and clove) with varying proportion of individual spice ingredients was investigated through four standard methods. Our results suggest that clove is the major contributor to the AOC of the five-spice powder whereas the other four ingredients contribute to the flavour. For example, the total phenolic content as well as ferric reducing antioxidant power (FRAP), Trolox equivalent antioxidant capacity (TEAC) and oxygen radical absorbance capacity (ORAC) values increased linearly with the clove percentage in five-spice powder. This observation opens the door to use clove in other spice mixtures to increase their AOC and flavour. Moreover, linear relationships were also observed between AOC and the total phenolic content of the 32 tested spice samples.

  8. Error of the modelled peak flow of the hydraulically reconstructed 1907 flood of the Ebro River in Xerta (NE Iberian Peninsula)

    Science.gov (United States)

    Lluís Ruiz-Bellet, Josep; Castelltort, Xavier; Carles Balasch, J.; Tuset, Jordi

    2016-04-01

    The estimation of the uncertainty of the results of the hydraulic modelling has been deeply analysed, but no clear methodological procedures as to its determination have been formulated when applied to historical hydrology. The main objective of this study was to calculate the uncertainty of the resulting peak flow of a typical historical flood reconstruction. The secondary objective was to identify the input variables that influenced the result the most and their contribution to peak flow total error. The uncertainty of 21-23 October 1907 flood of the Ebro River (NE Iberian Peninsula) in the town of Xerta (83,000 km2) was calculated with a series of local sensitivity analyses of the main variables affecting the resulting peak flow. Besides, in order to see to what degree the result depended on the chosen model, the HEC-RAS resulting peak flow was compared to the ones obtained with the 2D model Iber and with Manning's equation. The peak flow of 1907 flood in the Ebro River in Xerta, reconstructed with HEC-RAS, was 11500 m3·s-1 and its total error was ±31%. The most influential input variable over HEC-RAS peak flow results was water height; however, the one that contributed the most to peak flow error was Manning's n, because its uncertainty was far greater than water height's. The main conclusion is that, to ensure the lowest peak flow error, the reliability and precision of the flood mark should be thoroughly assessed. The peak flow was 12000 m3·s-1 when calculated with the 2D model Iber and 11500 m3·s-1 when calculated with the Manning equation.

  9. Glacial erosion, rock, and peak uplift within the central Transantarctic Mountains

    International Nuclear Information System (INIS)

    Stern, T.A.; Baxter, A.K.

    2002-01-01

    About 1500 m of peak elevation can be ascribed to the isostatic response of valley incision within the central Transantarctic Mountains. This estimate, based on a 3D analysis of topography, and on rock uplift history, represents c. 33% of the maximum peak elevation within the Transantarctic Mountains. Input to the calculation includes a previoulsy published estimate for the variation of flexural rigidity across the western margin of East Antarctica, and a lithospheric free-edge at the Transantarctic Mountains Front. The rebound response is a complex function of lithospheric rigidity, wavelength or erosion, and lithospheric boundary conditions. We also calculate a maximum 4000 m of total rebound due to both valley incision and erosion of mountain tops. This represents 60% of the maximum rock uplift inferred for the mountain front on the bases of fission track data and flexure analysis. (author). 34 refs., 5 figs., 3 tabs

  10. Extragalactic Peaked-spectrum Radio Sources at Low Frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Callingham, J. R.; Gaensler, B. M.; Sadler, E. M.; Lenc, E. [Sydney Institute for Astronomy (SIfA), School of Physics, The University of Sydney, NSW 2006 (Australia); Ekers, R. D.; Bell, M. E. [CSIRO Astronomy and Space Science (CASS), Marsfield, NSW 2122 (Australia); Line, J. L. B.; Hancock, P. J.; Kapińska, A. D.; McKinley, B.; Procopio, P. [ARC Centre of Excellence for All-Sky Astrophysics (CAASTRO) (Australia); Hurley-Walker, N.; Tingay, S. J.; Franzen, T. M. O.; Morgan, J. [International Centre for Radio Astronomy Research (ICRAR), Curtin University, Bentley, WA 6102 (Australia); Dwarakanath, K. S. [Raman Research Institute (RRI), Bangalore 560080 (India); For, B.-Q. [International Centre for Radio Astronomy Research (ICRAR), The University of Western Australia, Crawley, WA 6009 (Australia); Hindson, L.; Johnston-Hollitt, M. [School of Chemical and Physical Sciences, Victoria University of Wellington, Wellington 6140 (New Zealand); Offringa, A. R., E-mail: joseph.callingham@sydney.edu.au [Netherlands Institute for Radio Astronomy (ASTRON), Dwingeloo (Netherlands); and others

    2017-02-20

    We present a sample of 1483 sources that display spectral peaks between 72 MHz and 1.4 GHz, selected from the GaLactic and Extragalactic All-sky Murchison Widefield Array (GLEAM) survey. The GLEAM survey is the widest fractional bandwidth all-sky survey to date, ideal for identifying peaked-spectrum sources at low radio frequencies. Our peaked-spectrum sources are the low-frequency analogs of gigahertz-peaked spectrum (GPS) and compact-steep spectrum (CSS) sources, which have been hypothesized to be the precursors to massive radio galaxies. Our sample more than doubles the number of known peaked-spectrum candidates, and 95% of our sample have a newly characterized spectral peak. We highlight that some GPS sources peaking above 5 GHz have had multiple epochs of nuclear activity, and we demonstrate the possibility of identifying high-redshift ( z > 2) galaxies via steep optically thin spectral indices and low observed peak frequencies. The distribution of the optically thick spectral indices of our sample is consistent with past GPS/CSS samples but with a large dispersion, suggesting that the spectral peak is a product of an inhomogeneous environment that is individualistic. We find no dependence of observed peak frequency with redshift, consistent with the peaked-spectrum sample comprising both local CSS sources and high-redshift GPS sources. The 5 GHz luminosity distribution lacks the brightest GPS and CSS sources of previous samples, implying that a convolution of source evolution and redshift influences the type of peaked-spectrum sources identified below 1 GHz. Finally, we discuss sources with optically thick spectral indices that exceed the synchrotron self-absorption limit.

  11. The dislocation-internal friction peak γ in tantalum

    International Nuclear Information System (INIS)

    Baur, J.; Benoit, W.; Schultz, H.

    1989-01-01

    Torsion-pendulum measurements were carried out on high-purity single crystal specimens of tantalum, having extremely low oxygen contents ( 2 peak, which appears close to γ is small traces of oxygen are presents. The γ 2 peak was formerly explained as a ''dislocation-enhanced Snoek peak''. The γ peak recovers at the peak temperature, whereas the γ 2 peak is more stable. On the basis of their results, and making use of earlier investigations of Rodrian and Schultz, the authors suggest that γ 2 is modified γ relaxation, related to screw-dislocation segments, stabilized by oxygen-decorated kinks. The stability of the γ 2 peak allows an accurate determination of the activation energy, found to be 1.00 +- 0.03 eV. This value is distinctly lower than the activation energy of the oxygen Snoek effect (1.10 eV) and is related here to the mechanism of ''kink-pair formation'' in screw dislocations, as the original γ peak. The numerical value is compatible with recent values derived from flow-stress measurements. The peak γ 2 shows increasing stability with increasing oxygen content. This is explained by single- and multi-decorated kinks

  12. Individual vision and peak distribution in collective actions

    Science.gov (United States)

    Lu, Peng

    2017-06-01

    People make decisions on whether they should participate as participants or not as free riders in collective actions with heterogeneous visions. Besides of the utility heterogeneity and cost heterogeneity, this work includes and investigates the effect of vision heterogeneity by constructing a decision model, i.e. the revised peak model of participants. In this model, potential participants make decisions under the joint influence of utility, cost, and vision heterogeneities. The outcomes of simulations indicate that vision heterogeneity reduces the values of peaks, and the relative variance of peaks is stable. Under normal distributions of vision heterogeneity and other factors, the peaks of participants are normally distributed as well. Therefore, it is necessary to predict distribution traits of peaks based on distribution traits of related factors such as vision heterogeneity and so on. We predict the distribution of peaks with parameters of both mean and standard deviation, which provides the confident intervals and robust predictions of peaks. Besides, we validate the peak model of via the Yuyuan Incident, a real case in China (2014), and the model works well in explaining the dynamics and predicting the peak of real case.

  13. Peak Load Regulation and Cost Optimization for Microgrids by Installing a Heat Storage Tank and a Portable Energy System

    Directory of Open Access Journals (Sweden)

    Hong Zhang

    2018-04-01

    Full Text Available With the rapid growth of electricity demands, many traditional distributed networks cannot cover their peak demands, especially in the evening. Additionally, with the interconnection of distributed electrical and thermal grids, system operational flexibility and energy efficiency can be affected as well. Therefore, by adding a portable energy system and a heat storage tank to the traditional distributed system, this paper proposes a newly defined distributed network to deal with the aforementioned problems. Simulation results show that by adding a portable energy system, fossil fuel energy consumption and daily operation cost can be reduced by 8% and 28.29%, respectively. Moreover, system peak load regulating capacity can be significantly improved. However, by introducing the portable energy system to the grid, system uncertainty can be increased to some extent. Therefore, chance constrained programming is proposed to control the system while considering system uncertainty. By applying Particle Swarm Optimization—Monte Carlo to solve the chance constrained programming, results show that power system economy and uncertainty can be compromised by selecting appropriate confidence levels α and β. It is also reported that by installing an extra heat storage tank, combined heat and power energy efficiency can be significantly improved and the installation capacity of the battery can be reduced.

  14. Isotope resolution of the iron peak

    International Nuclear Information System (INIS)

    Henke, R.P.; Benton, E.V.

    1977-01-01

    A stack of Lexan detectors from the Apollo 17 mission has been analyzed to obtain Z measurements of sufficient accuracy to resolve the iron peak into its isotopic components. Within this distribution several peaks are present. With the centrally located, most populated peak assumed to be 56 Fe, the measurements imply that the abundances of 54 Fe and 58 Fe are appreciable fractions of the 56 Fe abundance. This result is in agreement with those of Webber et al. and Siegman et al. but in disagreement with the predictions of Tsao et al. (Auth.)

  15. Determination of Antioxidant Capacity, Total Phenolic Content and Mineral Composition of Different Fruit Tissue of Five Apple Cultivars Grown in Chile Determinación de la Capacidad Antioxidante, contenido de Fenoles totales y Composición Mineral de Diferentes Tejidos de Frutos de Cinco Variedades de Manzana cultivadas en Chile

    Directory of Open Access Journals (Sweden)

    Carolina Henríquez

    2010-12-01

    Full Text Available Apples (Malus domestica Borkh. have been identified as one of the main dietary sources of antioxidants, mainly phenolic compounds. These compounds vary in their composition and concentration, among cultivars and fruit tissues. In this research, the total phenolic content (Folin-Ciocalteau assay, antioxidant capacity (Ferric Reducing Antioxidant Power, FRAP assay and mineral composition in three fruit tissues (peel, pulp and whole fruit, of apple cultivars commonly used for dried apple production in Chile, were studied. In addition, the physical-chemical characteristics (dry weight, pH, titratable acidity, soluble solids content and color were also evaluated. The results indicated that the total phenolic content, the antioxidant capacity, and the mineral composition, of peel were substantially higher than those of whole fruit, and pulp for all the cultivars studied. Among cultivars, ‘Red Delicious’ apple peels have a significantly much higher content of total phenolic (11.6 mg gallic acid equivalents [GAE] g-1 FW and a higher FRAP (209.9 µmol Fe+2 g-1 FW. Additionally, a high correlation between total phenolic content and antioxidant capacity was found in all the cultivars and fruit tissues analyzed, except in the apple pulp. On the other hand, the physical and chemical composition differed among cultivars and fruit tissues. In conclusion, our results demonstrated that the total phenolic content, antioxidant capacity, mineral composition, and physical and chemical characteristics vary considerably depending on the apple cultivars and fruit tissues analyzed.Las manzanas (Malus domestica Borkh. han sido identificadas como una de las principales fuentes de antioxidantes en la dieta, principalmente de compuestos fenólicos. Estos compuestos varían en su composición y concentración según el cultivar y el tejido del fruto. En esta investigación se determinó: el contenido de fenoles totales (ensayo de Folin-Ciocalteau, la capacidad

  16. Instream flow needs below peaking hydroelectric projects

    International Nuclear Information System (INIS)

    Milhous, R.T.

    1991-01-01

    This paper reports on a method developed to assist in the determination of instream flow needs below hydroelectric projects operated in a peaking mode. Peaking hydroelectric projects significantly change streamflow over a short period of time; consequently, any instream flow methodology must consider the dual flows associated with peaking projects. The dual flows are the lowest flow and the maximum generation flow of a peaking cycle. The methodology is based on elements of the Physical Habitat Simulation System of the U.S. Fish and Wildlife Service and uses habitat, rather than fish numbers or biomas, as at basic response variable. All aquatic animals are subject to the rapid changes in streamflow which cause rapid swings in habitat quality. Some aquatic organisms are relatively fixed in location in the stream while others can move when flows change. The habitat available from a project operated in peaking mode is considered to be the minimum habitat occurring during a cycle of habitat change. The methodology takes in to consideration that some aquatic animals can move and others cannot move during a peaking cycle

  17. flowPeaks: a fast unsupervised clustering for flow cytometry data via K-means and density peak finding.

    Science.gov (United States)

    Ge, Yongchao; Sealfon, Stuart C

    2012-08-01

    For flow cytometry data, there are two common approaches to the unsupervised clustering problem: one is based on the finite mixture model and the other on spatial exploration of the histograms. The former is computationally slow and has difficulty to identify clusters of irregular shapes. The latter approach cannot be applied directly to high-dimensional data as the computational time and memory become unmanageable and the estimated histogram is unreliable. An algorithm without these two problems would be very useful. In this article, we combine ideas from the finite mixture model and histogram spatial exploration. This new algorithm, which we call flowPeaks, can be applied directly to high-dimensional data and identify irregular shape clusters. The algorithm first uses K-means algorithm with a large K to partition the cell population into many small clusters. These partitioned data allow the generation of a smoothed density function using the finite mixture model. All local peaks are exhaustively searched by exploring the density function and the cells are clustered by the associated local peak. The algorithm flowPeaks is automatic, fast and reliable and robust to cluster shape and outliers. This algorithm has been applied to flow cytometry data and it has been compared with state of the art algorithms, including Misty Mountain, FLOCK, flowMeans, flowMerge and FLAME. The R package flowPeaks is available at https://github.com/yongchao/flowPeaks. yongchao.ge@mssm.edu Supplementary data are available at Bioinformatics online.

  18. The case for a new capacity mechanism in the UK electricity market-Lessons from Australia and New Zealand

    International Nuclear Information System (INIS)

    Carstairs, Jamie; Pope, Ian

    2011-01-01

    The UK Government plans a capacity mechanism to ensure sufficient reserves as the share of intermittent generation increases. This article reviews the use of last resort capacity mechanisms in two other energy-only markets, Australia and New Zealand. The Australian National Electricity Market has infrequent price spikes up to A$12,500 ( Pounds 7800)/MWh. Option contracts have supported significant investment in peak capacity. The system operator also has an ability to contract reserve up to 9 months before projected shortfalls. Reserve has been contracted on two occasions but never dispatched. The New Zealand electricity market includes a reserve energy scheme which allows the system operator to contract and dispatch reserve capacity. One plant has been contracted under the scheme. The plant is currently offered into the market at NZ$5000 ( Pounds 2300)/MWh. In both markets there have been concerns that reserve schemes could reduce the frequency of high prices and damage price signals for peak investment. Following a Ministerial review in 2009 the New Zealand scheme is being closed down and the plant is for sale. The Australian scheme is to be closed down in 2013. This experience raises concerns about the possible impact of a new capacity mechanism in Great Britain. - Highlights: → The UK is considering a capacity mechanism targeted at new generation and dispatched as a last resort. → Australia and New Zealand are shutting down reserve schemes due to impact on investment incentives. → This shows that energy only markets can deliver sufficient reserves without a capacity mechanism. → An optimal response may be to ensure price signals are strong enough to ensure necessary investment. → If price signals are too weak a market wide response would be preferable to a targeted mechanism.

  19. Degree of thoracic kyphosis and peak torque of trunk flexors and extensors among healthy women☆☆☆

    Science.gov (United States)

    Granito, Renata Neves; Aveiro, Mariana Chaves; Rennó, Ana Claudia Muniz; Oishi, Jorge; Driusso, Patricia

    2014-01-01

    Objective The aim of this study was to analyze the effects of aging on the degree of thoracic kyphosis and peak torque of the trunk flexor and extensor muscles among women without a densitometric diagnosis of osteoporosis. Methods Thirty women were selected to make up three groups: young women (n = 10; 24.60 ± 2.27 years of age); adults (n = 10; 43.50 ± 2.88); and elderly women (n = 10; 62.40 ± 2.67). Bone mineral density (BMD), degree of thoracic kyphosis and peak torque of the trunk flexors and extensors were evaluated. Differences between the groups were evaluated using the Kruskal–Wallis ANOVA and Mann–Whitney U tests. Pearson's correlation coefficient was used to assess correlations between the variables. The significance level was taken to be 5% (p ≤ 0.05). Results The elderly group presented a greater degree of thoracic kyphosis (p = 0.009) and lower peak torque of the trunk flexors and extensors than the young group. The adult group presented lower peak torque of the trunk than the young group. A negative correlation was observed between age and peak torque of the trunk flexors and extensors (p ≤ 0.001), and a positive correlation between age and the degree of thoracic kyphosis (r = 0.58; p ≤ 0.001). The elderly group presented higher values for the eccentric/concentric ratio of the peak torque for flexors (p = 0.03) and extensors (p = 0.02). Conclusion This study suggests that physiological aging may be associated with a greater degree of thoracic kyphosis and lower muscle strength of the trunk flexors and extensors. Moreover, the elderly women showed a relative capacity for preservation of eccentric strength. PMID:26229814

  20. H-M bearing capacity of a modified suction caisson determined by using load-/displacement-controlled methods

    Science.gov (United States)

    Zhang, Yu-kun; Gao, Yu-feng; Li, Da-yong; Mahfouz, Ali H.

    2016-12-01

    This paper presents a series of monotonically combined lateral loading tests to investigate the bearing capacity of the MSCs (modified suction caissons) in the saturated marine fine sand. The lateral loads were applied under load- and displacement-controlled methods at the loading eccentricity ratios of 1.5, 2.0 and 2.5. Results show that, in the displacement-controlled test, the deflection-softening behavior of load-deflection curves for MSCs was observed, and the softening degree of the load-deflection response increased with the increasing external skirt length or the decreasing loading eccentricity. It was also found that the rotation center of the MSC at failure determined by the load-controlled method is slightly lower than that by the displacement-controlled method. The calculated MSC capacity based on the rotation center position in serviceability limit state is relatively conservative, compared with the calculated capacity based on the rotation center position in the ultimate limit state. In the limit state, the passive earth pressures opposite the loading direction under load- and displacement-controlled methods decrease by 46% and 74% corresponding to peak values, respectively; however, the passive earth pressures in the loading direction at failure only decrease by approximately 3% and 7%, compared with their peak values.

  1. A new approach for modeling the peak utility impacts from a proposed CUAC standard

    Energy Technology Data Exchange (ETDEWEB)

    LaCommare, Kristina Hamachi; Gumerman, Etan; Marnay, Chris; Chan, Peter; Coughlin, Katie

    2004-08-01

    This report describes a new Berkeley Lab approach for modeling the likely peak electricity load reductions from proposed energy efficiency programs in the National Energy Modeling System (NEMS). This method is presented in the context of the commercial unitary air conditioning (CUAC) energy efficiency standards. A previous report investigating the residential central air conditioning (RCAC) load shapes in NEMS revealed that the peak reduction results were lower than expected. This effect was believed to be due in part to the presence of the squelch, a program algorithm designed to ensure changes in the system load over time are consistent with the input historic trend. The squelch applies a system load-scaling factor that scales any differences between the end-use bottom-up and system loads to maintain consistency with historic trends. To obtain more accurate peak reduction estimates, a new approach for modeling the impact of peaky end uses in NEMS-BT has been developed. The new approach decrements the system load directly, reducing the impact of the squelch on the final results. This report also discusses a number of additional factors, in particular non-coincidence between end-use loads and system loads as represented within NEMS, and their impacts on the peak reductions calculated by NEMS. Using Berkeley Lab's new double-decrement approach reduces the conservation load factor (CLF) on an input load decrement from 25% down to 19% for a SEER 13 CUAC trial standard level, as seen in NEMS-BT output. About 4 GW more in peak capacity reduction results from this new approach as compared to Berkeley Lab's traditional end-use decrement approach, which relied solely on lowering end use energy consumption. The new method has been fully implemented and tested in the Annual Energy Outlook 2003 (AEO2003) version of NEMS and will routinely be applied to future versions. This capability is now available for use in future end-use efficiency or other policy analysis

  2. Upper limit of peak area

    International Nuclear Information System (INIS)

    Helene, O.A.M.

    1982-08-01

    The determination of the upper limit of peak area in a multi-channel spectra, with a known significance level is discussed. This problem is specially important when the peak area is masked by the background statistical fluctuations. The problem is exactly solved and, thus, the results are valid in experiments with small number of events. The results are submitted to a Monte Carlo test and applied to the 92 Nb beta decay. (Author) [pt

  3. A Peaking and Tailing Approach to Education and Curriculum Renewal for Sustainable Development

    Directory of Open Access Journals (Sweden)

    Cheryl Desha

    2014-07-01

    Full Text Available Contextual factors for sustainable development such as population growth, energy, and resource availability and consumption levels, food production yield, and growth in pollution, provide numerous complex and rapidly changing education and training requirements for a variety of professions including engineering. Furthermore, these requirements may not be clearly understood or expressed by designers, governments, professional bodies or the industry. Within this context, this paper focuses on one priority area for greening the economy through sustainable development—improving energy efficiency—and discusses the complexity of capacity building needs for professionals. The paper begins by acknowledging the historical evolution of sustainability considerations, and the complexity embedded in built environment solutions. The authors propose a dual-track approach to building capacity building, with a short-term focus on improvement (i.e., making peaking challenges a priority for postgraduate education, and a long-term focus on transformational innovation (i.e., making tailing challenges a priority for undergraduate education. A case study is provided, of Australian experiences over the last decade with regard to the topic area of energy efficiency. The authors conclude with reflections on implications for the approach.

  4. Analytical profiling of selected antioxidants and total antioxidant capacity of goji (Lycium spp.) berries.

    Science.gov (United States)

    Protti, Michele; Gualandi, Isacco; Mandrioli, Roberto; Zappoli, Sergio; Tonelli, Domenica; Mercolini, Laura

    2017-09-05

    Goji berries and derived products represent a relevant source of micronutrients, most of which are natural antioxidants and contribute to the high nutritional quality of these fruits. Three brands of dried goji berries have been analysed by a multidisciplinary approach to get an insight into both their content of selected antioxidants and their antioxidant capacity (AC). The former goal has been achieved by developing a liquid chromatographic method coupled to mass spectrometry and combined to a fast solid phase extraction. Several significant representative antioxidant compounds belonging to the following classes: flavonoids, flavan-3-ols, phenolic acids, amino acids and derivatives, and carotenoids have been taken into account. Quercetin and rutin were found to be the predominant flavonoids, chlorogenic acid was the most abundant phenolic acid and zeaxanthin was the major carotenoid. The AC of the goji berries has been evaluated by four analytical methods in order to estimate the contributions of different reactions involved in radicals scavenging. In particular, AC has been determined using 3 standardised methods (DPPH, ABTS, ORAC) and a recently proposed electrochemical method, which measures the scavenging activity of antioxidants towards OH radicals generated both by hydrogen peroxide photolysis and the Fenton reaction. The results obtained from chemical composition and antioxidant capacity assays confirm the high nutritional and commercial value of goji berries and highlight that the three brands do not exhibit significant differences. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Determination of total phenolic compound contents and antioxidant capacity of persimmon skin

    Directory of Open Access Journals (Sweden)

    M Mohamadi

    2012-05-01

    Full Text Available Due to the adverse side effects of synthetic antioxidants, the search for natural and safe antioxidants has become crucial. In this study, the total phenolic compound contents and antioxidants activity of persimmon skin was investigated. The extraction was carried out by means of maceration method using ethanol and methanol solvents with ratio of 1 part persimmon skin to 5 parts of solvents. Afterwards, the total phenolic compounds and antioxidants activity was measured. According to the results, ethanolic and methanolic extracts contained 255.6 and 214.15 mg gallic acid per 100 g of persimmon skin, respectively. Moreover, ethanolic extracts showed a higher activity for scavenging free radicals compared to methanolic extracts.

  6. Correlation between the body balance and functional capacity from elderly with chronic vestibular disorders.

    Science.gov (United States)

    Sousa, Raquel Ferreira de; Gazzola, Juliana Maria; Ganança, Maurício Malavasi; Paulino, Célia Aparecida

    2011-01-01

    Vestibular disorders are common among the elderly, mainly resulting in dizziness and imbalance--symptoms which can impact daily routine activities. To study the correlation between body balance and functional capacity and a comparison of risk of falls, actual falls and the functional capacity of the elderly with chronic vestibular dysfunctions. A cross-sectional, clinical and experimental study with 50 senior citizens--60 to 86 years, with chronic peripheral vestibular dysfunction. These participants underwent body balance assessment by the Dynamic Gait Index (DGI) and functional capacity assessment by the Functional Independence Measure (FIM). The data was tested using the Spearman correlation and comparison tests, Mann-Whitney and Kruskal-Wallis, being α=5% (0.05). There was a significant correlation between the total DGI score and all FIM scores, especially the total score (r=0.447; pfunctional capacity in elderly patients with the highest risk of falling (pfunctional capacity in elderly patients with peripheral vestibular disorders, that is: the better the balance, the better the individual's functional capacity. In addition, a worse functional capacity increases the individual's risk of falling.

  7. Effects of Cycling Versus Running Training on Sprint and Endurance Capacity in Inline Speed Skating

    Science.gov (United States)

    Stangier, Carolin; Abel, Thomas; Mierau, Julia; Hollmann, Wildor; Strüder, Heiko K.

    2016-01-01

    The purpose of this study was to compare the effects of running versus cycling training on sprint and endurance capacity in inline speed skating. Sixteen elite athletes (8 male, 8 female, 24 ± 8 yrs) were randomly assigned into 2 training groups performing either 2 session per week of treadmill running or ergometer cycling in addition to 3 skating specific sessions (technique, plyometrics, parkour) for 8 weeks. Training intensity was determined within non-specific (cycling or running) and effects on specific endurance capacity within a specific incremental exercise test. Before and after the intervention all athletes performed a specific (300m) and one non-specific (30s cycling or 200m running) all-out sprint test according to the group affiliation. To determine the accumulation of blood lactate (BLa) and glucose (BGL) 20 μl arterialized blood was drawn at rest, as well as in 1 min intervals for 10 min after the sprint test. The sport-specific peak oxygen uptake (VO2 peak) was significantly increased (+17%; p = 0.01) in both groups and highly correlated with the sprint performance (r = -0.71). BLa values decreased significantly (-18%, p = 0.02) after the specific sprint test from pre to post-testing without any group effect. However, BGL values only showed a significant decrease (-2%, p = 0.04) in the running group. The close relationship between aerobic capacity and sprint performance in inline speed skating highlights the positive effects of endurance training. Although both training programs were equally effective in improving endurance and sprint capacities, the metabolic results indicate a faster recovery after high intensity efforts for all athletes, as well as a higher reliance on the fat metabolism for athletes who trained in the running group. Key points In addition to a highly developed aerobic performance inline speed skaters also require a highly trained anaerobic capacity to be effective in the sprint sections such as the mass start, tactical attacks

  8. Economic performance of water storage capacity expansion for food security

    Science.gov (United States)

    Gohar, Abdelaziz A.; Ward, Frank A.; Amer, Saud A.

    2013-03-01

    SummaryContinued climate variability, population growth, and rising food prices present ongoing challenges for achieving food and water security in poor countries that lack adequate water infrastructure. Undeveloped storage infrastructure presents a special challenge in northern Afghanistan, where food security is undermined by highly variable water supplies, inefficient water allocation rules, and a damaged irrigation system due three decades of war and conflict. Little peer-reviewed research to date has analyzed the economic benefits of water storage capacity expansions as a mechanism to sustain food security over long periods of variable climate and growing food demands needed to feed growing populations. This paper develops and applies an integrated water resources management framework that analyzes impacts of storage capacity expansions for sustaining farm income and food security in the face of highly fluctuating water supplies. Findings illustrate that in Afghanistan's Balkh Basin, total farm income and food security from crop irrigation increase, but at a declining rate as water storage capacity increases from zero to an amount equal to six times the basin's long term water supply. Total farm income increases by 21%, 41%, and 42% for small, medium, and large reservoir capacity, respectively, compared to the existing irrigation system unassisted by reservoir storage capacity. Results provide a framework to target water infrastructure investments that improve food security for river basins in the world's dry regions with low existing storage capacity that face ongoing climate variability and increased demands for food security for growing populations.

  9. Outpatient rehabilitation as an intervention to improve employees' physical capacity.

    Science.gov (United States)

    Ojala, Birgitta; Nygård, Clas-Håkan; Nikkari, Seppo T

    2016-01-01

    The aging of the workforce poses new challenges for maintaining work ability. Because of limited information on the effectiveness of vocational rehabilitation performed in traditional inpatient programs, extended interest in outpatient rehabilitation has risen in the past few years. We examined the effects of a new outpatient rehabilitation program where every participant defined their own goals to improve work ability by the aid of a goal-oriented multi-professional team. This report will focus on the employees' physical capacity during a nine-month program. A total of 605 municipal employees from different production areas of the City of Tampere took part in the outpatient rehabilitation program, implemented by the occupational health unit. Groups of 12 employees participated in eight one-day sessions at intervals of two to three weeks; the final follow-up was 9 months from the beginning. Submaximal aerobic capacity was tested by a calibrated cycle ergometer with a commercial program (Aino Fitware pro, Helsinki, Finland). Musculoskeletal tests assessed muscle strength, balance and mobility. During the 9-month follow-up of the rehabilitation program, the employees' physical capacity was improved. The follow-up test scores from a total of 329 employees were significantly higher in the submaximal aerobic capacity test (p health situation to take part in physical capacity tests; however they took part in the intervention. The new outpatient rehabilitation program organized by the occupational health unit had a positive influence on employees' physical capacity during a nine-month follow up.

  10. From seed to cooked pasta: influence of traditional and non-conventional transformation processes on total antioxidant capacity and phenolic acid content.

    Science.gov (United States)

    Martini, Daniela; Ciccoritti, Roberto; Nicoletti, Isabella; Nocente, Francesca; Corradini, Danilo; D'Egidio, Maria Grazia; Taddei, Federica

    2018-02-01

    The aim of this work was to compare the traditional with a non-conventional (i.e. kernel micronisation) durum wheat milling process by monitoring the content of bound, conjugated and free phenolic acids (PAs) and the level of the total antioxidant capacity (TAC) occurring in the durum wheat pasta production chain, from seed to cooked pasta. The traditional transformation processes negatively influenced TAC and PA content (40% and 89% decrease from seed to cooked pasta, respectively), mainly during the milling process (25% and 84% decrease of TAC and PA, respectively), which has been related to the removal of external layers of kernels. Conversely, the micronisation applied on durum wheat kernels allowed to obtain whole-wheat pasta that preserved the seed endowment of antioxidant compounds even in cooked pasta. These results indicate the micronisation as a valuable approach to produce pasta with improved nutritional value and potential health-promoting effects compared to the traditional pasta.

  11. Employer Attitudes towards Peak Hour Avoidance

    NARCIS (Netherlands)

    Vonk Noordegraaf, D.M.; Annema, J.A.

    2012-01-01

    Peak Hour Avoidance is a relatively new Dutch mobility management measure. To reduce congestion frequent car drivers are given a financial reward for reducing the proportion of trips that they make during peak hours on a specific motorway section. Although previous studies show that employers are

  12. Employer attitudes towards peak hour avoidance

    NARCIS (Netherlands)

    Noordegraaf, D.M.V.; Annema, J.A.

    2012-01-01

    Peak Hour Avoidance is a relatively new Dutch mobility management measure. To reduce congestion frequent car drivers are given a financial reward for reducing the proportion of trips that they make during peak hours on a specific motorway section. Although previous studies show that employers are

  13. KiDS-450: cosmological constraints from weak-lensing peak statistics - II: Inference from shear peaks using N-body simulations

    Science.gov (United States)

    Martinet, Nicolas; Schneider, Peter; Hildebrandt, Hendrik; Shan, HuanYuan; Asgari, Marika; Dietrich, Jörg P.; Harnois-Déraps, Joachim; Erben, Thomas; Grado, Aniello; Heymans, Catherine; Hoekstra, Henk; Klaes, Dominik; Kuijken, Konrad; Merten, Julian; Nakajima, Reiko

    2018-02-01

    We study the statistics of peaks in a weak-lensing reconstructed mass map of the first 450 deg2 of the Kilo Degree Survey (KiDS-450). The map is computed with aperture masses directly applied to the shear field with an NFW-like compensated filter. We compare the peak statistics in the observations with that of simulations for various cosmologies to constrain the cosmological parameter S_8 = σ _8 √{Ω _m/0.3}, which probes the (Ωm, σ8) plane perpendicularly to its main degeneracy. We estimate S8 = 0.750 ± 0.059, using peaks in the signal-to-noise range 0 ≤ S/N ≤ 4, and accounting for various systematics, such as multiplicative shear bias, mean redshift bias, baryon feedback, intrinsic alignment, and shear-position coupling. These constraints are ˜ 25 per cent tighter than the constraints from the high significance peaks alone (3 ≤ S/N ≤ 4) which typically trace single-massive haloes. This demonstrates the gain of information from low-S/N peaks. However, we find that including S/N KiDS-450. Combining shear peaks with non-tomographic measurements of the shear two-point correlation functions yields a ˜20 per cent improvement in the uncertainty on S8 compared to the shear two-point correlation functions alone, highlighting the great potential of peaks as a cosmological probe.

  14. Evidence for a peak shift in a humoral response to helminths: age profiles of IgE in the Shuar of Ecuador, the Tsimane of Bolivia, and the U.S. NHANES.

    Directory of Open Access Journals (Sweden)

    Aaron D Blackwell

    2011-06-01

    Full Text Available The peak shift model predicts that the age-profile of a pathogen's prevalence depends upon its transmission rate, peaking earlier in populations with higher transmission and declining as partial immunity is acquired. Helminth infections are associated with increased immunoglobulin E (IgE, which may convey partial immunity and influence the peak shift. Although studies have noted peak shifts in helminths, corresponding peak shifts in total IgE have not been investigated, nor has the age-patterning been carefully examined across populations. We test for differences in the age-patterning of IgE between two South American forager-horticulturalist populations and the United States: the Tsimane of Bolivia (n=832, the Shuar of Ecuador (n=289, and the U.S. NHANES (n=8,336. We then examine the relationship between total IgE and helminth prevalences in the Tsimane.Total IgE levels were assessed in serum and dried blood spots and age-patterns examined with non-linear regression models. Tsimane had the highest IgE (geometric mean =8,182 IU/ml, followed by Shuar (1,252 IU/ml, and NHANES (52 IU/ml. Consistent with predictions, higher population IgE was associated with steeper increases at early ages and earlier peaks: Tsimane IgE peaked at 7 years, Shuar at 10 years, and NHANES at 17 years. For Tsimane, the age-pattern was compared with fecal helminth prevalences. Overall, 57% had detectable eggs or larva, with hookworm (45.4% and Ascaris lumbricoides (19.9% the most prevalent. The peak in total IgE occurred around the peak in A. lumbricoides, which was associated with higher IgE in children <10, but with lower IgE in adolescents.The age-patterning suggests a peak shift in total IgE similar to that seen in helminth infections, particularly A. lumbricoides. This age-patterning may have implications for understanding the effects of helminths on other health outcomes, such as allergy, growth, and response to childhood vaccination.

  15. Evidence for a peak shift in a humoral response to helminths: age profiles of IgE in the Shuar of Ecuador, the Tsimane of Bolivia, and the U.S. NHANES.

    Science.gov (United States)

    Blackwell, Aaron D; Gurven, Michael D; Sugiyama, Lawrence S; Madimenos, Felicia C; Liebert, Melissa A; Martin, Melanie A; Kaplan, Hillard S; Snodgrass, J Josh

    2011-06-01

    The peak shift model predicts that the age-profile of a pathogen's prevalence depends upon its transmission rate, peaking earlier in populations with higher transmission and declining as partial immunity is acquired. Helminth infections are associated with increased immunoglobulin E (IgE), which may convey partial immunity and influence the peak shift. Although studies have noted peak shifts in helminths, corresponding peak shifts in total IgE have not been investigated, nor has the age-patterning been carefully examined across populations. We test for differences in the age-patterning of IgE between two South American forager-horticulturalist populations and the United States: the Tsimane of Bolivia (n=832), the Shuar of Ecuador (n=289), and the U.S. NHANES (n=8,336). We then examine the relationship between total IgE and helminth prevalences in the Tsimane. Total IgE levels were assessed in serum and dried blood spots and age-patterns examined with non-linear regression models. Tsimane had the highest IgE (geometric mean =8,182 IU/ml), followed by Shuar (1,252 IU/ml), and NHANES (52 IU/ml). Consistent with predictions, higher population IgE was associated with steeper increases at early ages and earlier peaks: Tsimane IgE peaked at 7 years, Shuar at 10 years, and NHANES at 17 years. For Tsimane, the age-pattern was compared with fecal helminth prevalences. Overall, 57% had detectable eggs or larva, with hookworm (45.4%) and Ascaris lumbricoides (19.9%) the most prevalent. The peak in total IgE occurred around the peak in A. lumbricoides, which was associated with higher IgE in children <10, but with lower IgE in adolescents. The age-patterning suggests a peak shift in total IgE similar to that seen in helminth infections, particularly A. lumbricoides. This age-patterning may have implications for understanding the effects of helminths on other health outcomes, such as allergy, growth, and response to childhood vaccination.

  16. Coronary microvascular function, insulin sensitivity and body composition in predicting exercise capacity in overweight patients with coronary artery disease

    DEFF Research Database (Denmark)

    Jürs, Anders; Pedersen, Lene Rørholm; Olsen, Rasmus Huan

    2015-01-01

    BACKGROUND: Coronary artery disease (CAD) has a negative impact on exercise capacity. The aim of this study was to determine how coronary microvascular function, glucose metabolism and body composition contribute to exercise capacity in overweight patients with CAD and without diabetes. METHODS...... by a cardiopulmonary exercise test. Body composition was determined by whole body dual-energy X-ray absorptiometry scan and magnetic resonance imaging. Coronary flow reserve (CFR) assessed by transthoracic Doppler echocardiography was used as a measure of microvascular function. RESULTS: Median BMI was 31.3 and 72...... metabolism and body composition. CFR, EDV and LVEF remained independent predictors of VO2peak in multivariable regression analysis. CONCLUSION: The study established CFR, EDV and LVEF as independent predictors of VO2peak in overweight CAD patients with no or only mild functional symptoms and a LVEF > 35...

  17. Bayesian Peak Picking for NMR Spectra

    KAUST Repository

    Cheng, Yichen

    2014-02-01

    Protein structure determination is a very important topic in structural genomics, which helps people to understand varieties of biological functions such as protein-protein interactions, protein–DNA interactions and so on. Nowadays, nuclear magnetic resonance (NMR) has often been used to determine the three-dimensional structures of protein in vivo. This study aims to automate the peak picking step, the most important and tricky step in NMR structure determination. We propose to model the NMR spectrum by a mixture of bivariate Gaussian densities and use the stochastic approximation Monte Carlo algorithm as the computational tool to solve the problem. Under the Bayesian framework, the peak picking problem is casted as a variable selection problem. The proposed method can automatically distinguish true peaks from false ones without preprocessing the data. To the best of our knowledge, this is the first effort in the literature that tackles the peak picking problem for NMR spectrum data using Bayesian method.

  18. Practical load management - Peak shaving using photovoltaics

    International Nuclear Information System (INIS)

    Berger, W.

    2009-01-01

    This article takes a look at how photovoltaic (PV) power generation can be used in a practical way to meet peak demands for electricity. Advice is provided on how photovoltaics can provide peak load 'shaving' through the correlation between its production and the peak loads encountered during the day. The situation regarding feed-in tariffs in Italy is discussed, as are further examples of installations in Germany and Austria. Further, an initiative of the American Southern California Edison utility is discussed which foresees the installation of large PV plant on the roofs of commercial premises to provide local generation of peak energy and thus relieve demands on their power transportation network.

  19. Effect of Caloric Restriction or Aerobic Exercise Training on Peak Oxygen Consumption and Quality of Life in Obese Older Patients with Heart Failure and Preserved Ejection Fraction A Randomized, Controlled Trial

    Science.gov (United States)

    Kitzman, Dalane W.; Brubaker, Peter; Morgan, Timothy; Haykowsky, Mark; Hundley, Gregory; Kraus, William E.; Eggebeen, Joel; Nicklas, Barbara J.

    2016-01-01

    Importance More than 80% of patients with heart failure with preserved ejection fraction (HFPEF), the most common form of HF among older persons, are overweight/obese. Exercise intolerance is the primary symptom of chronic HFPEF and a major determinant of reduced quality-of-life (QOL). Objective To determine whether caloric restriction (Diet), or aerobic exercise training (Exercise), improves exercise capacity and QOL in obese older HFPEF patients. Design Randomized, attention-controlled, 2x2 factorial trial conducted from February 2009 November 2014. Setting Urban academic medical center. Participants 100 older (67±5 years) obese (BMI=39.3±5.6kg/m2) women (n=81) and men (n=19) with chronic, stable HFPEF enrolled from 577 patients initially screened (366 excluded by inclusion / exclusion criteria, 31 for other reasons, 80 declined participation). Twenty-six participants were randomized to Exercise alone, 24 to Diet alone, 25 to Diet+Exercise, and 25 to Control; 92 completed the trial. Interventions 20 weeks of Diet and/or Exercise; Attention Control consisted of telephone calls every 2 weeks. Main Outcomes and Measures Exercise capacity measured as peak oxygen consumption (VO2, ml/kg/min; primary outcome) and QOL measured by the Minnesota Living with HF Questionnaire (MLHF) total score (co-primary outcome; score range: 0–105, higher scores indicate worse HF-related QOL). Results By main effects analysis, peak VO2 was increased significantly by both interventions: Exercise main effect 1.2 ml/kg/min (95%CI: 0.7,1.7; pDiet main effect 1.3 ml/kg/min (95%CI: 0.8,1.8; pExercise+Diet was additive (complementary) for peak VO2 (joint effect 2.5 ml/kg/min). The change in MLHF total score was non-significant with Exercise (main effect −1 unit; 95%CI: −8,5; p=0.70) and with Diet (main effect −6 units; 95%CI: −12,1; p=0.078). The change in peak VO2 was positively correlated with the change in percent lean body mass (r=0.32; p=0.003) and the change in thigh muscle

  20. Decreasing fuel cost weight in electric utility business. ; Urged peak measures and management constitution improvement. Denki jigyo no nenryohi weight wa gensho. ; Isogareru peak taisaku to keiei taishitsu kaizen

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The electric power industry has made stable and economic power supply possible by advancing diversification in power sources and shifting the petroleum supply sources to southern countries and China. The cost constitution of the electric utility business in the fiscal year 1992 was such that the ratio of fuel cost is 15.9% against the total cost amount of 13 trillion 399.3 billion yen. As opposed, the fuel cost percent in the fiscal 1980 was 37.7%. This means that the effect of the fuel cost on the total cost has become smaller even if the fuel cost varies as a result of external factors including fluctuation in foreign exchange rates. Peaks in the power demand have been recorded in day time in high summer when air conditioning demand increases, which have been growing year after year. Expenses to maintain facilities and functions to deal with this demand increase have been increasing. The owned capital ratio in the electric power business was 15.7% in the fiscal 1992, which is by far lower than the average of whole industry of 28%. Execution of measures against the power peaks and improvement of the management constitution are the problems posed on the electric power industry. 4 figs., 1 tab.