WorldWideScience

Sample records for total internal fluorescence

  1. Total Internal Reflection Fluorescence Microscopy Imaging-Guided Confocal Single-Molecule Fluorescence Spectroscopy

    OpenAIRE

    Zheng, Desheng; Kaldaras, Leonora; Lu, H. Peter

    2013-01-01

    We have developed an integrated spectroscopy system combining total internal reflection fluorescence microscopy imaging with confocal single-molecule fluorescence spectroscopy for two-dimensional interfaces. This spectroscopy approach is capable of both multiple molecules simultaneously sampling and in situ confocal fluorescence dynamics analyses of individual molecules of interest. We have demonstrated the calibration with fluorescent microspheres, and carried out single-molecule spectroscop...

  2. Single-Molecule Fluorescence Studies of Membrane Transporters Using Total Internal Reflection Microscopy.

    Science.gov (United States)

    Goudsmits, Joris M H; van Oijen, Antoine M; Slotboom, Dirk J

    2017-01-01

    Cells are delineated by a lipid bilayer that physically separates the inside from the outer environment. Most polar, charged, or large molecules require proteins to reduce the energetic barrier for passage across the membrane and to achieve transport rates that are relevant for life. Here, we describe techniques to visualize the functioning of membrane transport proteins with fluorescent probes at the single-molecule level. First, we explain how to produce membrane-reconstituted transporters with fluorescent labels. Next, we detail the construction of a microfluidic flow cell to image immobilized proteoliposomes on a total internal reflection fluorescence microscope. We conclude by describing the methods that are needed to analyze fluorescence movies and obtain useful single-molecule data. © 2017 Elsevier Inc. All rights reserved.

  3. Microplate-compatible total internal reflection fluorescence microscopy for receptor pharmacology

    Science.gov (United States)

    Chen, Minghan; Zaytseva, Natalya V.; Wu, Qi; Li, Min; Fang, Ye

    2013-05-01

    We report the use of total internal reflection fluorescence (TIRF) microscopy for analyzing receptor pharmacology and the development of a microplate-compatible TIRF imaging system. Using stably expressed green fluorescence protein tagged β2-adrenergic receptor as the reporter, we found that the activation of different receptors results in distinct kinetic signatures of the TIRF intensity of cells. These TIRF signatures closely resemble the characteristics of their respective label-free dynamic mass redistribution signals in the same cells. This suggests that TIRF in microplate can be used for profiling and screening drugs.

  4. Combining total internal reflection sum frequency spectroscopy spectral imaging and confocal fluorescence microscopy.

    Science.gov (United States)

    Allgeyer, Edward S; Sterling, Sarah M; Gunewardene, Mudalige S; Hess, Samuel T; Neivandt, David J; Mason, Michael D

    2015-01-27

    Understanding surface and interfacial lateral organization in material and biological systems is critical in nearly every field of science. The continued development of tools and techniques viable for elucidation of interfacial and surface information is therefore necessary to address new questions and further current investigations. Sum frequency spectroscopy (SFS) is a label-free, nonlinear optical technique with inherent surface specificity that can yield critical organizational information on interfacial species. Unfortunately, SFS provides no spatial information on a surface; small scale heterogeneities that may exist are averaged over the large areas typically probed. Over the past decade, this has begun to be addressed with the advent of SFS microscopy. Here we detail the construction and function of a total internal reflection (TIR) SFS spectral and confocal fluorescence imaging microscope directly amenable to surface investigations. This instrument combines, for the first time, sample scanning TIR-SFS imaging with confocal fluorescence microscopy.

  5. Nanograting-based plasmon enhancement for total internal reflection fluorescence microscopy of live cells

    International Nuclear Information System (INIS)

    Kim, Kyujung; Cho, Eun-Jin; Suh, Jin-Suck; Huh, Yong-Min; Kim, Donghyun; Kim, Dong Jun

    2009-01-01

    We investigated evanescent field enhancement based on subwavelength nanogratings for improved sensitivity in total internal reflection microscopy of live cells. The field enhancement is associated with subwavelength-grating-coupled plasmon excitation. An optimum sample employed a silver grating on a silver film and an SF10 glass substrate. Field intensity was enhanced by approximately 90% when measured by fluorescent excitation of microbeads relative to that on a bare prism as a control, which is in good agreement with numerical results. The subwavelength-grating-mediated field enhancement was also applied to live cell imaging of quantum dots, which confirmed the sensitivity enhancement qualitatively.

  6. Single cell adhesion strength assessed with variable-angle total internal reflection fluorescence microscopy

    Directory of Open Access Journals (Sweden)

    Marcelina Cardoso Dos Santos

    2017-06-01

    Full Text Available We propose a new strategy to evaluate adhesion strength at the single cell level. This approach involves variable-angle total internal reflection fluorescence microscopy to monitor in real time the topography of cell membranes, i.e. a map of the membrane/substrate separation distance. According to the Boltzmann distribution, both potential energy profile and dissociation energy related to the interactions between the cell membrane and the substrate were determined from the membrane topography. We have highlighted on glass substrates coated with poly-L-lysine and fibronectin, that the dissociation energy is a reliable parameter to quantify the adhesion strength of MDA-MB-231 motile cells.

  7. Live Imaging of Cellular Internalization of Single Colloidal Particle by Combined Label-Free and Fluorescence Total Internal Reflection Microscopy.

    Science.gov (United States)

    Byrne, Gerard D; Vllasaliu, Driton; Falcone, Franco H; Somekh, Michael G; Stolnik, Snjezana

    2015-11-02

    In this work we utilize the combination of label-free total internal reflection microscopy and total internal reflectance fluorescence (TIRM/TIRF) microscopy to achieve a simultaneous, live imaging of single, label-free colloidal particle endocytosis by individual cells. The TIRM arm of the microscope enables label free imaging of the colloid and cell membrane features, while the TIRF arm images the dynamics of fluorescent-labeled clathrin (protein involved in endocytosis via clathrin pathway), expressed in transfected 3T3 fibroblasts cells. Using a model polymeric colloid and cells with a fluorescently tagged clathrin endocytosis pathway, we demonstrate that wide field TIRM/TIRF coimaging enables live visualization of the process of colloidal particle interaction with the labeled cell structure, which is valuable for discerning the membrane events and route of colloid internalization by the cell. We further show that 500 nm in diameter model polystyrene colloid associates with clathrin, prior to and during its cellular internalization. This association is not apparent with larger, 1 μm in diameter colloids, indicating an upper particle size limit for clathrin-mediated endocytosis.

  8. Variable-angle total internal reflection fluorescence microscopy of intact cells of Arabidopsis thaliana

    Directory of Open Access Journals (Sweden)

    Kim Myung K

    2011-09-01

    Full Text Available Abstract Background Total internal reflection fluorescence microscopy (TIRFM is a powerful tool for observing fluorescently labeled molecules on the plasma membrane surface of animal cells. However, the utility of TIRFM in plant cell studies has been limited by the fact that plants have cell walls, thick peripheral layers surrounding the plasma membrane. Recently, a new technique known as variable-angle epifluorescence microscopy (VAEM was developed to circumvent this problem. However, the lack of a detailed analysis of the optical principles underlying VAEM has limited its applications in plant-cell biology. Results Here, we present theoretical and experimental evidence supporting the use of variable-angle TIRFM in observations of intact plant cells. We show that when total internal reflection occurs at the cell wall/cytosol interface with an appropriate angle of incidence, an evanescent wave field of constant depth is produced inside the cytosol. Results of experimental TIRFM observations of the dynamic behaviors of phototropin 1 (a membrane receptor protein and clathrin light chain (a vesicle coat protein support our theoretical analysis. Conclusions These findings demonstrate that variable-angle TIRFM is appropriate for quantitative live imaging of cells in intact tissues of Arabidopsis thaliana.

  9. Widefield and total internal reflection fluorescent structured illumination microscopy with scanning galvo mirrors

    Science.gov (United States)

    Chen, Youhua; Cao, Ruizhi; Liu, Wenjie; Zhu, Dazhao; Zhang, Zhiming; Kuang, Cuifang; Liu, Xu

    2018-04-01

    We present an alternative approach to realize structured illumination microscopy (SIM), which is capable for live cell imaging. The prototype utilizes two sets of scanning galvo mirrors, a polarization converter and a piezo-platform to generate a fast shifted, s-polarization interfered and periodic variable illumination patterns. By changing the angle of the scanning galvanometer, we can change the position of the spots at the pupil plane of the objective lens arbitrarily, making it easy to switch between widefield and total internal reflection fluorescent-SIM mode and adapting the penetration depth in the sample. Also, a twofold resolution improvement is achieved in our experiments. The prototype offers more flexibility of pattern period and illumination orientation changing than previous systems.

  10. Imaging Early Steps of Sindbis Virus Infection by Total Internal Reflection Fluorescence Microscopy

    Directory of Open Access Journals (Sweden)

    Youling Gu

    2011-01-01

    Full Text Available Sindbis virus (SINV is an alphavirus that has a broad host range and has been widely used as a vector for recombinant gene transduction, DNA-based vaccine production, and oncolytic cancer therapy. The mechanism of SINV entry into host cells has yet to be fully understood. In this paper, we used single virus tracking under total internal reflection fluorescence microscopy (TIRFM to investigate SINV attachment to cell surface. Biotinylated viral particles were labeled with quantum dots, which retained viral viability and infectivity. By time-lapse imaging, we showed that the SINV exhibited a heterogeneous dynamics on the surface of the host cells. Analysis of SINV motility demonstrated a two-step attachment reaction. Moreover, dual color TIRFM of GFP-Rab5 and SINV suggested that the virus was targeted to the early endosomes after endocytosis. These findings demonstrate the utility of quantum dot labeling in studying the early steps and behavior of SINV infection.

  11. Quantifying the Assembly of Multicomponent Molecular Machines by Single-Molecule Total Internal Reflection Fluorescence Microscopy.

    Science.gov (United States)

    Boehm, E M; Subramanyam, S; Ghoneim, M; Washington, M Todd; Spies, M

    2016-01-01

    Large, dynamic macromolecular complexes play essential roles in many cellular processes. Knowing how the components of these complexes associate with one another and undergo structural rearrangements is critical to understanding how they function. Single-molecule total internal reflection fluorescence (TIRF) microscopy is a powerful approach for addressing these fundamental issues. In this article, we first discuss single-molecule TIRF microscopes and strategies to immobilize and fluorescently label macromolecules. We then review the use of single-molecule TIRF microscopy to study the formation of binary macromolecular complexes using one-color imaging and inhibitors. We conclude with a discussion of the use of TIRF microscopy to examine the formation of higher-order (i.e., ternary) complexes using multicolor setups. The focus throughout this article is on experimental design, controls, data acquisition, and data analysis. We hope that single-molecule TIRF microscopy, which has largely been the province of specialists, will soon become as common in the tool box of biophysicists and biochemists as structural approaches have become today. © 2016 Elsevier Inc. All rights reserved.

  12. New light on ion channel imaging by total internal reflection fluorescence (TIRF) microscopy.

    Science.gov (United States)

    Yamamura, Hisao; Suzuki, Yoshiaki; Imaizumi, Yuji

    2015-05-01

    Ion channels play pivotal roles in a wide variety of cellular functions; therefore, their physiological characteristics, pharmacological responses, and molecular structures have been extensively investigated. However, the mobility of an ion channel itself in the cell membrane has not been examined in as much detail. A total internal reflection fluorescence (TIRF) microscope allows fluorophores to be imaged in a restricted region within an evanescent field of less than 200 nm from the interface of the coverslip and plasma membrane in living cells. Thus the TIRF microscope is useful for selectively visualizing the plasmalemmal surface and subplasmalemmal zone. In this review, we focused on a single-molecule analysis of the dynamic movement of ion channels in the plasma membrane using TIRF microscopy. We also described two single-molecule imaging techniques under TIRF microscopy: fluorescence resonance energy transfer (FRET) for the identification of molecules that interact with ion channels, and subunit counting for the determination of subunit stoichiometry in a functional channel. TIRF imaging can also be used to analyze spatiotemporal Ca(2+) events in the subplasmalemma. Single-molecule analyses of ion channels and localized Ca(2+) signals based on TIRF imaging provide beneficial pharmacological and physiological information concerning the functions of ion channels. Copyright © 2015 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  13. Adhesion of living cells revealed by variable-angle total internal reflection fluorescence microscopy (Conference Presentation)

    Science.gov (United States)

    Cardoso Dos Santos, Marcelina; Vézy, Cyrille; Jaffiol, Rodolphe

    2016-02-01

    Total Internal Reflection Fluorescence Microscopy (TIRFM) is a widespread technique to study cellular process occurring near the contact region with the glass substrate. In this field, determination of the accurate distance from the surface to the plasma membrane constitutes a crucial issue to investigate the physical basis of cellular adhesion process. However, quantitative interpretation of TIRF pictures regarding the distance z between a labeled membrane and the substrate is not trivial. Indeed, the contrast of TIRF images depends on several parameters more and less well known (local concentration of dyes, absorption cross section, angular emission pattern…). The strategy to get around this problem is to exploit a series of TIRF pictures recorded at different incident angles in evanescent regime. This technique called variable-angle TIRF microscopy (vaTIRFM), allowing to map the membrane-substrate separation distance with a nanometric resolution (10-20 nm). vaTIRFM was developed by Burmeister, Truskey and Reichert in the early 1990s with a prism-based TIRF setup [Journal of Microscopy 173, 39-51 (1994)]. We propose a more convenient prismless setup, which uses only a rotatable mirror to adjust precisely the laser beam on the back focal plane of the oil immersion objective (no azimuthal scanning is needed). The series of TIRF images permit us to calculate accurately membrane-surface distances in each pixel. We demonstrate that vaTIRFM are useful to quantify the adhesion of living cells for specific and unspecific membrane-surface interactions, achieved on various functionalized substrates with polymers (BSA, poly-L-lysin) or extracellular matrix proteins (collagen and fibronectin).

  14. Quantification of protein based on single-molecule counting by total internal reflection fluorescence microscopy with adsorption equilibrium

    International Nuclear Information System (INIS)

    Wang Lei; Xu Guang; Shi Zhikun; Jiang Wei; Jin Wenrui

    2007-01-01

    We developed a sensitive single-molecule imaging method for quantification of protein by total internal reflection fluorescence microscopy with adsorption equilibrium. In this method, the adsorption equilibrium of protein was achieved between solution and glass substrate. Then, fluorescence images of protein molecules in a evanescent wave field were taken by a highly sensitive electron multiplying charge coupled device. Finally, the number of fluorescent spots corresponding to the protein molecules in the images was counted. Alexa Fluor 488-labeled goat anti-rat IgG(H + L) was chosen as the model protein. The spot number showed an excellent linear relationship with protein concentration. The concentration linear range was 5.4 x 10 -11 to 8.1 x 10 -10 mol L -1

  15. Quantitative analysis of phosphoinositide 3-kinase (PI3K) signaling using live-cell total internal reflection fluorescence (TIRF) microscopy.

    Science.gov (United States)

    Johnson, Heath E; Haugh, Jason M

    2013-12-02

    This unit focuses on the use of total internal reflection fluorescence (TIRF) microscopy and image analysis methods to study the dynamics of signal transduction mediated by class I phosphoinositide 3-kinases (PI3Ks) in mammalian cells. The first four protocols cover live-cell imaging experiments, image acquisition parameters, and basic image processing and segmentation. These methods are generally applicable to live-cell TIRF experiments. The remaining protocols outline more advanced image analysis methods, which were developed in our laboratory for the purpose of characterizing the spatiotemporal dynamics of PI3K signaling. These methods may be extended to analyze other cellular processes monitored using fluorescent biosensors. Copyright © 2013 John Wiley & Sons, Inc.

  16. Studying flow close to an interface by total internal reflection fluorescence cross-correlation spectroscopy: Quantitative data analysis

    Science.gov (United States)

    Schmitz, R.; Yordanov, S.; Butt, H. J.; Koynov, K.; Dünweg, B.

    2011-12-01

    Total internal reflection fluorescence cross-correlation spectroscopy (TIR-FCCS) has recently [S. Yordanov , Optics ExpressOPEXFF1094-408710.1364/OE.17.021149 17, 21149 (2009)] been established as an experimental method to probe hydrodynamic flows near surfaces, on length scales of tens of nanometers. Its main advantage is that fluorescence occurs only for tracer particles close to the surface, thus resulting in high sensitivity. However, the measured correlation functions provide only rather indirect information about the flow parameters of interest, such as the shear rate and the slip length. In the present paper, we show how to combine detailed and fairly realistic theoretical modeling of the phenomena by Brownian dynamics simulations with accurate measurements of the correlation functions, in order to establish a quantitative method to retrieve the flow properties from the experiments. First, Brownian dynamics is used to sample highly accurate correlation functions for a fixed set of model parameters. Second, these parameters are varied systematically by means of an importance-sampling Monte Carlo procedure in order to fit the experiments. This provides the optimum parameter values together with their statistical error bars. The approach is well suited for massively parallel computers, which allows us to do the data analysis within moderate computing times. The method is applied to flow near a hydrophilic surface, where the slip length is observed to be smaller than 10nm, and, within the limitations of the experiments and the model, indistinguishable from zero.

  17. Total internal reflection fluorescence (TIRF) microscopy for real-time imaging of nanoparticle-cell plasma membrane interaction

    DEFF Research Database (Denmark)

    Parhamifar, Ladan; Moghimi, Seyed Moien

    2012-01-01

    Nanoparticulate systems are widely used for site-specific drug and gene delivery as well as for medical imaging. The mode of nanoparticle-cell interaction may have a significant effect on the pathway of nanoparticle internalization and subsequent intracellular trafficking. Total internal reflection...

  18. Three-dimensional particle tracking in concave structures made by ultraviolet nanoimprint via total internal reflection fluorescence microscopy and refractive-index-matching method

    Science.gov (United States)

    Fujinami, Taku; Kigami, Hiroshi; Unno, Noriyuki; Taniguchi, Jun; Satake, Shin-ichi

    2018-03-01

    Total internal reflection fluorescence microscopy (TIRFM) is a promising method for measuring fluid flow close to a wall with nanoscale resolution in a process that is termed "multilayer nanoparticle image velocimetry" (MnPIV). TIRFM uses evanescent light that is generated on a substrate (typically a glass slide) by total internal reflection of light. Many researchers have previously studied x-y-z (3D) flows of water close to flat glass slides using MnPIV. On the other hand, a fluid flow close to a structured surface is also important. To measure flows of water near micro-patterns, we previously developed an MnPIV technique that uses a refractive-index-matching method. In previous study, the micropattern is made of a thermoplastic material with a refractive index that closely matches that of water. In this study, ultraviolet nanoimprint lithography was used for fabricating the appropriate micro-patterns because this technique can fabricate a pattern with a high resolution. As a result, we succeeded in performing MnPIV in water with a circular hole array pattern made by ultraviolet nanoimprint using a refractive-index-matching method. We believe that this technique will be helpful in elucidating fluid flows around microstructures.

  19. Total reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Michaelis, W.; Prange, A.

    1987-01-01

    In the past few years, total reflection X-ray flourescence analysis (TXRF) has found an increasing number of assignments and applications. Experience of trace element analysis using TXRF and examples of applications are already widespread. Therefore, users of TXRF had the opportunity of an intensive exchange of their experience at the 1st workshop on total reflection X-ray fluorescence analysis which took place on May 27th and 28th 1986 at the GKSS Research Centre at Geesthacht. In a series of lectures and discussions dealing with the analytical principle itself, sample preparation techniques and applications as well as comuter programs for spectrum evaluation, the present state of development and the range of applications were outlined. 3 studies out of a total of 14 were included separately in the INIS and ENERGY databases. With 61 figs., 12 tabs [de

  20. Determination of technetium by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bermudez, J.I.; Greaves, E.D.; Nemeth, P.

    2000-01-01

    We describe a technique using total reflection x-ray fluorescence (TXRF) for determination of Technetium produced by elution of chromatography generators with physiological saline solutions. The analysis with the 18.41 keV K α line of Technetium was accomplished with monochromatized K α radiation from a silver anode x-ray tube operated at 45 keV and 20 mA. This radiation at 22.104 keV is efficiently coupled to the 21.054 keV absorption edge of Tc. It is also of advantage in the direct analysis of organic and saline properties of the Tc-bearing samples. Quantification was accomplished by internal standard addition of Ga and using an interpolated value of the sensitivity for Tc between Molybdenum and Rhenium. Data processing was carried out with the QXAS-AXIL software package. System sensitivity was found adequate for direct Tc determination of eluted saline solutions. The interest and advantages of the use of the technique as an auxiliary in the synthesis and characterization of Tc-labeled radiopharmaceuticals used for diagnosis in nuclear medicine are discussed. Detection limits in the matrices analyzed are reported. (author)

  1. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    International Nuclear Information System (INIS)

    Dhara, Sangita; Misra, N.L.; Maind, S.D.; Kumar, Sanjukta A.; Chattopadhyay, N.; Aggarwal, S.K.

    2010-01-01

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 μL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO 3 /HClO 4 , mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1σ) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  2. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    Energy Technology Data Exchange (ETDEWEB)

    Dhara, Sangita [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Misra, N.L., E-mail: nlmisra@barc.gov.i [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Maind, S.D. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Kumar, Sanjukta A. [Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Chattopadhyay, N. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Aggarwal, S.K. [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2010-02-15

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 muL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO{sub 3}/HClO{sub 4}, mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1sigma) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  3. Fluorescent fingerprints of edible oils and biodiesel by means total synchronous fluorescence and Tucker3 modeling

    Science.gov (United States)

    Insausti, Matías; de Araújo Gomes, Adriano; Camiña, José Manuel; de Araújo, Mario Cesar Ugulino; Band, Beatriz Susana Fernández

    2017-03-01

    The present work proposes the use of total synchronous fluorescence spectroscopy (TSFS) as a discrimination methodology for fluorescent compounds in edible oils, which are preserved after the transesterification processes in the biodiesel production. In the same way, a similar study is presented to identify fluorophores that do not change in expired vegetal oils, to associate physicochemical parameters to fluorescent measures, as contribution to a fingerprint for increasing the chemical knowledge of these products. The fluorescent fingerprints were obtained by Tucker3 decomposition of a three-way array of the total synchronous fluorescence matrices. This chemometric method presents the ability for modeling non-bilinear data, as Total Synchronous Fluorescence Spectra data, and consists in the decomposition of the three way data arrays (samples × Δλ × λ excitation), into four new data matrices: A (scores), B (profile in Δλ mode), C (profile in spectra mode) and G (relationships between A, B and C). In this study, 50 samples of oil from soybean, corn and sunflower seeds before and after its expiration time, as well as 50 biodiesel samples obtained by transesterification of the same oils were measured by TSFS. This study represents an immediate application of chemical fingerprint for the discrimination of non-expired and expired edible oils and biodiesel. This method does not require the use of reagents or laborious procedures for the chemical characterization of samples.

  4. Total internal reflection effect on gyrotropic interface

    Science.gov (United States)

    Glushchenko, Alexander G.; Glushchenko, Eugene P.; Zhukov, Sergey V.

    2018-02-01

    This article considers the physical features of total internal reflection at gyrotropic and isotropic interfaces for two cases: electrical gyrotropy (plasma) and magnetic gyrotropy (ferrite). It is shown that the plasma magnetization may lead to the formation of the total internal reflection effect, which does not occur in isotropic plasma. The threshold values of the magnetic field, which are necessary for the total internal reflection effect, are determined. The total internal reflection effect on a ferrite-dielectric interface for waves emanating from different angles is observed in various frequency ranges and magnetization fields. The study points out the possibility of changing the total internal reflection angle value in large limits due to a change in the external magnetic field magnitude. The calculation results of the total internal reflection angle dependence on the external magnetic field magnitude are presented. The formulas are elaborated for calculating the total internal reflection angles of different interfaces for gyrotropic and isotropic media. The generalized formulas are defined for calculating the Doppler effect in the gyrotropic media. The study demonstrates how the velocity of the media interface affects the limiting angle of total internal refection.

  5. Total reflection x-ray fluorescence - an approach to nanoanalysis

    International Nuclear Information System (INIS)

    Klockenkaemper, R.

    2000-01-01

    X-ray fluorescence analysis (XRFA) is a powerful tool used for industrial production, geological prospecting and for environmental control. However, the method suffers from a lack of sensitivity so that analyses are restricted to microanalytical investigations. That means: the sample amount needed for analysis is above some 10 micrograms, concentrations to be determined have to be on the μg/ml level, and thin layers to be characterized must be of micrometer thickness. In contrast to conventional XRFA, total-reflection X-ray fluorescence (TXRF) is extremely sensitive and even allows nano-analytical investigations. Three different ways can be taken: (i) use of minute sample amounts of only 10 nano-grams, (ii) determination of extreme traces below ng/ml and (iii) surface analysis and depth profiling of shallow layers with nano-meter thickness. In this lecture, the basic physical phenomena of total reflection and standing waves are outlined. The experimental equipment for TXRF is sketched out and commercially available instruments of different manufacturers are compared. Furthermore, examples are given for the three kinds of nano-analytical applications: ultra-micro, analysis, ultra trace analysis and mono- and thin-layer analysis. (author)

  6. Total-reflection X-ray fluorescence analysis of Austrian wine

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, X. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Kregsamer, P. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Wobrauschek, P. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Streli, C. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria)]. E-mail: streli@ati.ac.at

    2006-11-15

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 {mu}l of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines.

  7. Total-reflection X-ray fluorescence analysis of Austrian wine

    International Nuclear Information System (INIS)

    Gruber, X.; Kregsamer, P.; Wobrauschek, P.; Streli, C.

    2006-01-01

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 μl of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines

  8. Beer analysis by synchrotron radiation total reflection X-ray fluorescence (SR-TXRF)

    International Nuclear Information System (INIS)

    Moreira, Silvana; Vives, Ana Elisa S. de; Nascimento Filho, Virgilio F.; Zucchi, Orgheda L.D.A.

    2005-01-01

    In this work the concentrations of P, S, Cl, K, Ca, Mn, Fe, Zn and Br in twenty-nine brands of national and international beers were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF). The results were compared with the limits established by the Brazilian Legislation and the nutritive values established by National Agricultural Library (NAL). The measurements were performed at the X-ray Fluorescence Beamline at Synchrotron Light Source Laboratory, in Campinas, Sao Paulo, Brazil, using a polychromatic beam for excitation. A small volume of 5 μL of sample beers containing just an internal standard, used to correct geometry effects, were analyzed without any pre-treatment. The measuring time was 100 s and the detection limits obtained varied from 1μg.L -1 for Mn and Fe to 15μg.L -1 for P. (author)

  9. Beer analysis by synchrotron radiation total reflection X-ray fluorescence (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo. Dept. de Recursos Hidricos]. E-mail: silvana@fec.unicamp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Nascimento Filho, Virgilio F. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear]. E-mail: virgilio@cena.usp.br; Zucchi, Orgheda L.D.A. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas de Ribeirao Preto]. E-mail: olzucchi@fcfrp.usp.br

    2005-07-01

    In this work the concentrations of P, S, Cl, K, Ca, Mn, Fe, Zn and Br in twenty-nine brands of national and international beers were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF). The results were compared with the limits established by the Brazilian Legislation and the nutritive values established by National Agricultural Library (NAL). The measurements were performed at the X-ray Fluorescence Beamline at Synchrotron Light Source Laboratory, in Campinas, Sao Paulo, Brazil, using a polychromatic beam for excitation. A small volume of 5 {mu}L of sample beers containing just an internal standard, used to correct geometry effects, were analyzed without any pre-treatment. The measuring time was 100 s and the detection limits obtained varied from 1{mu}g.L{sup -1} for Mn and Fe to 15{mu}g.L{sup -1} for P. (author)

  10. Total and available metal contents in sediments by synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Moreira, Silvana; Sobrinho, Gilmar A.; Jesus, Edgar F.O. de; Lopes, Ricardo T.

    2002-01-01

    In this work the total and available contents of Al, Si, Cl, K, Mn, Fe, Co, Ni, Cu, Zn, Sr, Zr, Ba, Ce and Pb in sediments from river Atibaia were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence technique. The detection limits for K series varies from 200 ng.mL -1 for Al to 2 ng.mL -1 for Zn while for L series the value varies from 20 ng.mL -1 for Ba to 10 ng.mL -1 for Pb. The samples were submitted to two different processes, in order to obtain the total and biological available metal contents. The information about metal content is a important parameter for a correct evaluation about the hydrologic cycle in Piracicaba basin. All the measure were carried out at the National Synchrotron Light Laboratory, Campinas, SP, Brazil, using a white beam for excitation. (author)

  11. Thin film characterization by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Danel, Adrien; Nolot, Emmanuel; Veillerot, Marc; Olivier, Segolene; Decorps, Tifenn; Calvo-Munoz, Maria-Luisa; Hartmann, Jean-Michel; Lhostis, Sandrine; Kohno, Hiroshi; Yamagami, Motoyuki; Geoffroy, Charles

    2008-01-01

    Sensitive and accurate characterization of films thinner than a few nm used in nanoelectronics represents a challenge for many conventional production metrology tools. With capabilities in the 10 10 at/cm 2 , methods usually dedicated to contamination analysis appear promising, especially Total-reflection X-Ray Fluorescence (TXRF). This study shows that under usual configuration for contamination analysis, with incident angle smaller than the critical angle of the substrate, TXRF signal saturation occurs very rapidly for dense films (below 0.5 nm for HfO 2 films on Si wafers using a 9.67 keV excitation at 0.5 deg.). Increasing the incident angle, the range of linear results can be extended, but on the other hand, the TXRF sensitivity is degraded because of a strong increase of the measurement dead time. On HfO 2 films grown on Si wafers, an incident angle of 0.32 deg. corresponding to a dead time of 95% was used to achieve linear analysis up to 2 nm. Composition analysis by TXRF, and especially the detection of minor elements into thin films, requires the use of a specific incident angle to optimize sensitivity. Although quantitative analyses might require specific calibration, this work shows on Co-based films that the ratio between minor elements (W, P, Mo) and Co taking into account their relative sensitivity factors is a good direct reading of the composition

  12. Total internal reflection tomography of small objects

    International Nuclear Information System (INIS)

    Chen Xudong

    2008-01-01

    The multiple signal classification (MUSIC) imaging method is applied to determine the locations of a collection of small anisotropic spherical scatterers in the framework of the total internal reflection tomography. Multiple scattering between scatterers is considered and the inverse scattering problem is nonlinear, which, however, is solved by the proposed fast analytical approach where no associated forward problem is iteratively evaluated. The paper also discusses the role of the polarization of incidence waves, the incidence angle, the separation of scatterers from the surface of the substrate, and the level of noise on the resolution of imaging.

  13. The capabilities of total reflection X-ray fluorescence in the polymeric analytical field

    International Nuclear Information System (INIS)

    Vazquez, Cristina

    2004-01-01

    This paper presents the capabilities of total reflection X-ray fluorescence (TXRF) as analytical technique specially focused in high-viscosity polymer dispersions. Appropriate sample preparation procedures are described taking into account the time stability of these dispersions. Special remarks considering different ways for drying samples in order to obtain the most uniform deposited film are investigated focusing on the behavior of aqueous and viscous systems. Due to the difficulty found for obtaining a homogeneous mixture between sample and internal standard in such systems, the use of Compton incoherent scattering is discussed as an alternative procedure for trace quantification in high viscous systems without any mixing processes

  14. The capabilities of total reflection X-ray fluorescence in the polymeric analytical field*1

    Science.gov (United States)

    Vázquez, Cristina

    2004-08-01

    This paper presents the capabilities of total reflection X-ray fluorescence (TXRF) as analytical technique specially focused in high-viscosity polymer dispersions. Appropriate sample preparation procedures are described taking into account the time stability of these dispersions. Special remarks considering different ways for drying samples in order to obtain the most uniform deposited film are investigated focusing on the behavior of aqueous and viscous systems. Due to the difficulty found for obtaining a homogeneous mixture between sample and internal standard in such systems, the use of Compton incoherent scattering is discussed as an alternative procedure for trace quantification in high viscous systems without any mixing processes.

  15. Frustrated Total Internal Reflection: A Simple Application and Demonstration.

    Science.gov (United States)

    Zanella, F. P.; Magalhaes, D. V.; Oliveira, M. M.; Bianchi, R. F.; Misoguti, L.; Mendonca, C. R.

    2003-01-01

    Describes the total internal reflection process that occurs when the internal angle of incidence is equal to or greater than the critical angle. Presents a demonstration of the effect of frustrated total internal reflection (FTIR). (YDS)

  16. Colouration of medieval glass bracelets studied by total reflection x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Detcheva, Albena; Velinova, Ralitsa; Ivanova, Elisaveta; Jordanov, Juri; Karadjov, Metody

    2014-01-01

    The contents of 3d-transition metals (Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn) in fragments of medieval glass bracelets, found in the necropolis of Stambolovo and the castle of Mezek, Bulgaria, were determined by total reflection X-ray fluorescence (TXRF) analysis using gallium as internal standard. The samples were analysed as slurries in Triton X 114. The experimental parameters: grain size of the glass sample, concentrations of glass sample, Triton X114 and internal standard in the slurry, volume of the slurry aliquot taken for analysis, as well as the excitation time, were optimised. For method validation the certified reference material BAM-S005 Type A soda-lime glass was used. It was proven that the elements Co, Mn and Fe are responsible for colour generation in the investigated glass samples. The precision of the determinations is characterised by an RSD in the range 3–11%

  17. Assisted Interpretation of Laser-Induced Fluorescence Spectra of Egg-Based Binding Media Using Total Emission Fluorescence Spectroscopy

    International Nuclear Information System (INIS)

    Anglos, D.; Nevin, A.

    2006-01-01

    Laser-induced fluorescence (LIF) spectroscopy can provide nondestructive, qualitative analysis of protein-based binding media found in artworks. Fluorescence emissions from proteins in egg yolk and egg white are due to auto fluorescent aromatic amino acids as well as other native and age-related fluorophores, but the potential of fluorescence spectroscopy for the differentiation between binding media is dependent on the choice of a suitable excitation wavelength and limited by problems in interpretation. However, a better understanding of emission spectra associated with LIF can be achieved following comparisons with total emission fluorescence spectra where a series of consecutive emission spectra are recorded over a specific range. Results using nanosecond UV laser sources for LIF of egg-based binding media are presented which are rationalised following comparisons with total emission spectra. Specifically, fluorescence is assigned to tryptophan and oxidation products of amino acids; in the case of egg yolk, fatty-acid polymerisation and age-related degradation products account for the formation of fluorophores.

  18. Direct analysis of biological samples by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Lue M, Marco P.; Hernandez-Caraballo, Edwin A.

    2004-01-01

    The technique of total reflection X-ray fluorescence (TXRF) is well suited for the direct analysis of biological samples due to the low matrix interferences and simultaneous multi-element nature. Nevertheless, biological organic samples are frequently analysed after digestion procedures. The direct determination of analytes requires shorter analysis time, low reactive consumption and simplifies the whole analysis process. On the other hand, the biological/clinical samples are often available in minimal amounts and routine studies require the analysis of large number of samples. To overcome the difficulties associated with the analysis of organic samples, particularly of solid ones, different procedures of sample preparation and calibration to approach the direct analysis have been evaluated: (1) slurry sampling, (2) Compton peak standardization, (3) in situ microwave digestion, (4) in situ chemical modification and (5) direct analysis with internal standardization. Examples of analytical methods developed by our research group are discussed. Some of them have not been previously published, illustrating alternative strategies for coping with various problems that may be encountered in the direct analysis by total reflection X-ray fluorescence spectrometry

  19. Chlorine determination in (U, Pu)C fuel by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Misra, Nand Lal; Dhara, Sangita; Mudher, Khush Dev Singh; Aggarwal, Suresh K.; Thakur, Uday Kumar; Shah, Dipti; Sawant, R.M.; Ramakumar, K.L.

    2007-01-01

    A Total Reflection X-ray Fluorescence (TXRF) method for the determination of chlorine in (U,Pu)C has been developed. The method involves calibration of the instrument with standard solutions and validation of TXRF determination of chlorine using synthetic standard solutions. Cl K α line excited with W L α source was used for TXRF determinations of chlorine. Chlorine present in trace amounts in (U,Pu)C samples was first separated by pyro hydrolysis. The evolved chlorine, in form of HCl, was collected in 5 mM NaOH solution. This solution was analyzed for chlorine by Total Reflection X-ray Fluorescence Spectrometry using cobalt as an internal standard. The TXRF detection limit of chlorine was found to be 3.6 pg with sample size of 30 μL. In order to assess the applicability of TXRF method for chlorine determinations in other nuclear materials, one U 3 O 8 trace element standard was also analyzed for chlorine in similar way. The precision of the method was found to be 25% (1 σ) at ng level in most of the cases. (author)

  20. Application of total reflection X-ray fluorescence spectrometry for ...

    Indian Academy of Sciences (India)

    Applicability of total reflection X-ray fluorescence (TXRF) spectrometry for trace elemental analysis of rainwater samples was studied. The study was used to develop these samples as rainwater standards by the National University of Singapore (NUS). Our laboratory was one of the participants to use TXRF for this study.

  1. Sweeping total reflection X-ray fluorescence optimisation to monitor the metallic contamination into IC manufacturing

    International Nuclear Information System (INIS)

    Borde, Yannick; Danel, Adrien; Roche, Agnes; Veillerot, Marc

    2008-01-01

    Among the methods available on the market today to control as metallic contamination in integrated circuit manufacturing, Sweeping Total reflection X-ray Fluorescence mode appears a very good method, providing fast and entire wafer mapping. With the goal of a pertinent use of Sweeping Total reflection X-ray Fluorescence in advanced Integrated Circuit manufacturing this work discusses how acceptable levels of contamination specified by the production (low levels to be detected) can be taken into account. The relation between measurement results (surface coverage, throughput, low limit of detection, limit of quantification, quantification of localized contamination) and Sweeping Total reflection X-ray Fluorescence parameters (number of measurement points and integration time per point) is presented in details. In particular, a model is proposed to explain the mismatch between actual surface contamination in a localized spot on wafer and Total reflection X-ray Fluorescence reading. Both calibration and geometric issues have been taken into account

  2. Determination of copper, iron and zinc in spirituous beverages by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Capote, T.; Marcó, L. M.; Alvarado, J.; Greaves, E. D.

    1999-10-01

    The concentration of copper in traditional homemade alcoholic distillates produced in Venezuela (Cocuy de Penca) were determined by total reflection X-ray fluorescence (TXRF) using vanadium as internal standard. The results were compared to those obtained by flame atomic absorption spectrometry (FAAS). Three preparative methods of addition of vanadium were compared: classical internal standard addition, 'layer on layer' internal standard addition and in situ addition of internal standard. The TXRF procedures were accurate and the precision was comparable to that obtained by the FAAS technique. Copper levels were above the maximum allowed limits for similar beverages. Zinc and iron in commercial and homemade distilled beverages were also analyzed by TXRF with in situ addition of internal standard demonstrating the usefulness of this technique for trace metal determination in distillates.

  3. Analysis of biological slurry samples by total x-ray fluorescence after in situ microwave digestion

    International Nuclear Information System (INIS)

    Lue-Meru, M.P.; Capote, T.; Greaves, E.

    2000-01-01

    Biological slurry samples were analyzed by total reflection x-ray fluorescence (TXRF) after an in situ microwave digestion procedure on the quartz reflector. This method lead to the removal of the matrix by the digestion and permits the enrichment of the analites by using sample amounts higher than those normally used in TXRF for the thin layer requirement since the organic matrix is removed. In consequence, the pre-concentration of sample is performed and the detection capability is increased by a quasi direct method. The samples analyzed were the international IAEA blood standard, the SRM bovine liver 1577-a standard and fresh onion tissues. Slurries were prepared in three ways: a.- weighing a sample amount on the reflector and adding suprapure nitric acid and internal standard followed by microwave digestion, b.-weighing a sample amount and water with an appropriate concentration of the internal standard in an Eppendorf vial, taking then an aliquot to the quartz reflector for microwave digestion with suprapure nitric acid, c.- weighing a sample amount of fresh tissue, homogenising with high speed homegenator to obtain a slurry sample which can be diluted in an ependorf vial with water an the internal standard. Then an aliquot is taken to the reflector for microwave digestion with suprapure nitric acid. Further details of sample preparation procedures will be discussed during presentation. The analysis was carried out in a Canberra spectrometer using the Kalpha lines of the Ag and Mo tubes. The elements Ca, K, Fe, Cu, Zn, Se, Mn, Rb, Br, Sr were determined. The effect of the preparation procedure was evaluated by the accuracy and precision of the results for each element and the percent of recovery. (author)

  4. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ovari, M.; Streli, C.; Wobrauschek, P.; Zaray, Gy.

    2009-01-01

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  5. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ovari, M. [Department of Analytical Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary)], E-mail: ovari@chem.elte.hu; Streli, C.; Wobrauschek, P. [Atominstitut of the Austrian Universities, TU-Wien, Stadionallee 2, A-1020, Wien (Austria); Zaray, Gy. [Department of Analytical Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary); Cooperative Research Centre of Environmental Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary)

    2009-08-15

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  6. Collection of airborne particulate matter for a subsequent analysis by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bayer, H.; Bohlen, A. von; Schmeling, M.; Klockow, D.

    1995-01-01

    The collection of airborne particulate matter by filtration and impaction was adapted to total reflection X-ray fluorescence analysis (TXRF). Cellulose nitrate filters were used for collecting in a Berner impactor. Single filter spots were punched out, placed on quartz-glass carriers, dissolved by tetrahydrofuran and re-precipitated prior to element determinations by TXRF. In a Battelle-type impactor, airborne dust was collected on Plexiglass carriers coated with medical Vaseline. The loaded carriers were directly analyzed by TXRF. In both cases, quantification was simply performed by the addition of an internal standard after sampling. Impactors were made of a suitable material in order to investigate high blank values, collection losses and memory effects. It could be shown that stainless steel, even coated with TiN, is less suitable and should be avoided as an impactor material. Although aluminum is partly recommendable, titanium and the polymer Makrolon are quite appropriate. By using an impactor made of these materials, a reliable multielement determination in airborne dust is made possible with low detection limits as low as 1 ng/m 3 and a satisfactory repeatability of a few %. Short sampling times of only 1 h or less can be realized. The total procedure is simple and time-saving, and can be recommended for routine investigations of airborne particulate matter. (author)

  7. The total antioxidant capacity and fluorescence imaging of selected plant leaves commonly consumed in Brunei Darussalam

    Science.gov (United States)

    Watu, Aswani; Metussin, Nurzaidah; Yasin, Hartini M.; Usman, Anwar

    2018-02-01

    We investigated the total antioxidant capacity and fluorescence imaging of several selected plants, namely Centella asiatica, Aidia borneensis and Anacardium occidentale, which are grown and traditionally consumed in Brunei Darussalam. The total antioxidant capacities of aqueous-methanolic infusions of their leaves were measured by 2,2-diphenyl-1-picrylhydrazyl (DPPH) free radical scavenging activity, and microscopic fluorescence images were measured to identify the fluorescent substances bound in the leaves. We found that the total antioxidant capacity of their infusions is estimated to be 150, 25, 15 folds, respectively, lower compared with that of the standard gallic acid. Accordingly, we demonstrated that the relative antioxidant activity of young and matured leaves agrees with the intensity of red light emission of their fresh leaves upon UV excitation. Thus, this non-invasive spectroscopic method can be potentially utilized to indicate the antioxidants in plant leaves qualitatively.

  8. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    International Nuclear Information System (INIS)

    Fernandez-Ruiz, R.; Garcia-Heras, M.

    2008-01-01

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies

  9. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, R. [Servicio Interdepartamental de Investigacion, Facultad de Ciencias, Universidad Autonoma de Madrid, Modulo C-9, Laboratorio de TXRF, Crta. Colmenar, Km 15, Cantoblanco, E-28049, Madrid (Spain)], E-mail: ramon.fernandez@uam.es; Garcia-Heras, M. [Grupo de Arqueometria de Vidrios y Materiales Ceramicos, Instituto de Historia, Centro de Ciencias Humanas y Sociales, CSIC, C/ Albasanz, 26-28, 28037 Madrid (Spain)

    2008-09-15

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies.

  10. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2010-01-01

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO 3 and H 2 O 2 (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different (α = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 μg g -1 . A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of 'Citrus Leaves' and a blank were treated in the same way.

  11. Metal ions diffusion through polymeric matrices: A total reflection X-ray fluorescence study

    International Nuclear Information System (INIS)

    Boeykens, S.; Caracciolo, N.; D'Angelo, M.V.; Vazquez, C.

    2006-01-01

    This work proposes the use of X-ray fluorescence with total reflection geometry to explore the metal ions transport in aqueous hydrophilic polymer solutions. It is centered in the study of polymer concentration influence on ion diffusion. This subject is relevant to various and diverse applications, such as drug controlled release, microbiologic corrosion protection and enhanced oil recovery. It is anticipated that diffusion is influenced by various factors in these systems, including those specific to the diffusing species, such as charge, shape, molecular size, and those related to the structural complexity of the matrix as well as any specific interaction between the diffusing species and the matrix. The diffusion of nitrate salts of Ba and Mn (same charge, different hydrodynamic radii) through water-swollen polymeric solutions and gels in the 0.01% to 1% concentration ranges was investigated. The measurements of the metal concentration were performed by TXRF analysis using the scattered radiation by the sample as internal standard. Results are discussed according to different physical models for solute diffusion in polymeric solutions

  12. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    Science.gov (United States)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2010-06-01

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO 3 and H 2O 2 (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different ( α = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 μg g - 1 . A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of "Citrus Leaves" and a blank were treated in the same way.

  13. Microanalysis of old violin varnishes by total-reflection X-ray fluorescence

    Science.gov (United States)

    von Bohlen, Alex; Meyer, Friedrich

    1997-07-01

    Total reflection X-ray fluorescence was used to characterize elements (with Z>13) contained in varnishes applied by prominent violin makers during the last five centuries. Direct analyses of small flakes with masses varnish. Higher amounts of Fe, As and Pb were found in old products, Mn, Co, Cu, Zn and Pb were used in more recent varnishes.

  14. The X-ray fluorescent method for determination of total sulphur in bituminous coals

    International Nuclear Information System (INIS)

    Widowska-Kusmierska, J.; Siess, K.

    1979-01-01

    The X-ray fluorescent technique for the determination of total sulphur covering concentrations from 0,1 to 10% has been applied for bituminous coals showing a great variability in qualitative and quantitative composition of mineral matter (ash). The described method is a quick one giving results during one hour. The obtained good accuracy of determinations gives prospects for wide industrial application. (author)

  15. Total reflection X-ray fluorescence with synchrotron radiation applied to biological and environmental samples

    International Nuclear Information System (INIS)

    Simabuco, S.M.; Matsumoto, E.; Jesus, E.F.O.; Lopes, R.T.; Perez, C.; Nascimento Filho, V.F.; Costa, R.S.S.; Tavares do Carmo, M.G.; Saunders, C.

    2001-01-01

    Full text: The Total Reflection X-ray Fluorescence has been applied for trace elements in water and aqueous solutions, environmental samples and biological materials after sample preparation and to surface analysis of silicon wafers. The present paper shows some results of applications for rainwater, atmospheric particulate material, colostrum and nuclear samples. (author)

  16. International survey of primary and revision total knee replacement

    NARCIS (Netherlands)

    Kurtz, Steven M.; Ong, Kevin L.; Lau, Edmund; Widmer, Marcel; Maravic, Milka; Gomez-Barrena, Enrique; de Pina, Maria de Fatima; Manno, Valerio; Torre, Marina; Walter, William L.; de Steiger, Richard; Geesink, Rudolph G. T.; Peltola, Mikko; Roeder, Christoph

    2011-01-01

    Total knee arthroplasty (TKA) is currently the international standard of care for treating degenerative and rheumatologic knee joint disease, as well as certain knee joint fractures. We sought to answer the following three research questions: (1) What is the international variance in primary and

  17. The role of total-reflection x-ray fluorescence in atomic spectroscopy

    International Nuclear Information System (INIS)

    Toelg, G.; Klockenkaemper, R.

    1993-01-01

    Total-reflection X-ray fluorescence (TXRF) is a universal and economic method for the simultaneous determination of elements with atomic numbers > 11 down to the lower pg-level. It is a microanalytical tool for the analysis of small sample amounts placed on flat carriers and for contaminations on flat sample surfaces. Analyses of stratified near-surface layers are made possible by varying the incident angle of the primary beam in the region of total-reflection. This non-destructive method is especially suitable for thin layers of a few nanometres, deposited on wafer material although not usable as a microprobe method with a high lateral resolution. Furthermore, depth profiles of biological samples can be recorded by means of microtome sectioning of only a few micrometres, as, for example in the gradient analysis of human organs. In addition to micro- and surface-layer analysis, TXRF is effectively applied to element trace analysis. Homogeneous solutions, for example aqueous solutions, high-purity acids or body fluids, are pipetted onto carriers and, after evaporation, the dry residues are analyzed directly down to the pg/ml region. Particularly advantageous is the absence of matrix effects, so that an easy calibration can be carried out by adding a single internal standard element. A digestion or separation step preceding the actual determination becomes necessary if a more complex matrix is to be analysed or especially low detection limits have to be reached. A critical evaluation of the recent developments in atomic spectroscopy places TXRF in a leading position. Its outstanding features compete with those of e.g. electrothermal atomic absorption spectrometry (ETAAS), microwave induced plasma optical emission spectroscopy (MIP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) in the field of micro- and trace analysis and with Rutherford backscattering (RBS) and secondary ion mass spectrometry (SIMS) in the surface-layer analysis. (author)

  18. The internalization of fluorescence-labeled PLA nanoparticles by macrophages.

    Science.gov (United States)

    Li, Fengjuan; Zhu, Aiping; Song, Xiaoli; Ji, Lijun; Wang, Juan

    2013-09-10

    Rhodamine B (RhB)-labeled PLA nanoparticles were prepared through surface grafting copolymerization of glycidyl methacrylate (GMA) onto PLA nanoparticles during the emulsion/evaporation process. RhB firstly interacts with sodium dodecyl sulfate (SDS) through electrostatic interaction to form hydrophobic complex (SDS-RhB). Due to the high-affinity of SDS-RhB with GMA, hydrophilic RhB can be successfully combined into PLA nanoparticles. The internalization of RhB-labeled PLA nanoparticles by macrophages was investigated with fluorescence microscope technology. The effects of the PLA nanoparticle surface nature and size on the internalization were investigated. The results indicate that the PLA particles smaller than 200 nm can avoid the uptake of phagocytosis. The bigger PLA particles (300 nm) with polyethylene glycol (PEG) surface showed less internalization by macrophage compared with those with poly(ethylene oxide-propylene oxide) copolymer (F127) or poly(vinyl alcohol) (PVA) surface. The "stealth" function of PEG on the PLA nanoparticles from internalization of macrophages due to the low protein adsorption is revealed by electrochemical impedance technology. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Total internal reflection and dynamic light scattering microscopy of gels

    Science.gov (United States)

    Gregor, Brian F.

    Two different techniques which apply optical microscopy in novel ways to the study of biological systems and materials were built and applied to several samples. The first is a system for adapting the well-known technique of dynamic light scattering (DLS) to an optical microscope. This can detect and scatter light from very small volumes, as compared to standard DLS which studies light scattering from volumes 1000x larger. The small scattering volume also allows for the observation of nonergodic dynamics in appropriate samples. Porcine gastric mucin (PGM) forms a gel at low pH which lines the epithelial cell layer and acts as a protective barrier against the acidic stomach environment. The dynamics and microscopic viscosity of PGM at different pH levels is studied using polystyrene microspheres as tracer particles. The microscopic viscosity and microrheological properties of the commercial basement membrane Matrigel are also studied with this instrument. Matrigel is frequently used to culture cells and its properties remain poorly determined. Well-characterized and purely synthetic Matrigel substitutes will need to have the correct rheological and morphological characteristics. The second instrument designed and built is a microscope which uses an interferometry technique to achieve an improvement in resolution 2.5x better in one dimension than the Abbe diffraction limit. The technique is based upon the interference of the evanescent field generated on the surface of a prism by a laser in a total internal reflection geometry. The enhanced resolution is demonstrated with fluorescent samples. Additionally. Raman imaging microscopy is demonstrated using the evanescent field in resonant and non-resonant samples, although attempts at applying the enhanced resolution technique to the Raman images were ultimately unsuccessful. Applications of this instrument include high resolution imaging of cell membranes and macroscopic structures in gels and proteins. Finally, a third

  20. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    Energy Technology Data Exchange (ETDEWEB)

    Fittschen, U.E.A. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: ursula.fittschen@chemie.uni-hamburg.de; Meirer, F. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: fmeirer@ati.ac.at; Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: streli@ati.ac.at; Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: wobi@ati.ac.at; Thiele, J. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: Julian.Thiele@gmx.de; Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22603 Hamburg (Germany)], E-mail: falkenbe@mail.desy.de; Pepponi, G. [ITC-irst, Via Sommarive 18, 38050 Povo (Trento) (Italy)], E-mail: pepponi@itc.it

    2008-12-15

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 {mu}m, 8.0-2.0 {mu}m, 2.0-0.13 {mu}m 0.13-0.015 {mu}m (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 {mu}m, 1-2 {mu}m, 2-4 {mu}m, 4-8 {mu}m, 8-16 {mu}m. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in

  1. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    International Nuclear Information System (INIS)

    Fittschen, U.E.A.; Meirer, F.; Streli, C.; Wobrauschek, P.; Thiele, J.; Falkenberg, G.; Pepponi, G.

    2008-01-01

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 μm, 8.0-2.0 μm, 2.0-0.13 μm 0.13-0.015 μm (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 μm, 1-2 μm, 2-4 μm, 4-8 μm, 8-16 μm. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in all particle size fractions

  2. Combining mid infrared and total X-ray fluorescence spectroscopy for prediction of soil properties

    Science.gov (United States)

    Towett, Erick; Shepherd, Keith; Sila, Andrew; Aynekulu, Ermias; Cadisch, Georg

    2015-04-01

    Mid-infrared diffuse reflectance spectroscopy (MIR) can predict many soil properties but extractable nutrients are often predicted poorly. We evaluated the potential of MIR and total elemental analysis using total X-ray fluorescence spectroscopy (TXRF), both individually and combined, to predict results of conventional soil tests. Total multi-elemental analysis provides a fingerprint of soil mineralogy and could predict some soil properties and help improve MIR predictions. A set of 700 georeferenced soil samples associated with the Africa Soil Information Service (AfSIS) (www.africasoils.net) from 44 stratified randomly-located 100-km2 sentinel sites distributed across sub-Saharan Africa were analysed for physico-chemical composition using conventional reference methods, and compared to MIR and TXRF spectra using the Random Forests regression algorithm and an internal out-of-bag validation. MIR spectra resulted in good prediction models (R2 >0.80) for organic C and total N, Mehlich-3 Ca and Al, and pH. To test the combined spectroscopic approach, TXRF element concentration data was included as a property predictor along with the first derivative of MIR spectral data using the RF algorithm. Including TXRF did not improve prediction of these properties. TXRF was poorer (R2 0.86) as these elements are not directly determined with TXRF, however the variance explained is still quite high and may be attributable to TXRF signatures relating to mineralogy correlated with protection of soil organic matter. TXRF model for Mehlich-3 Al had excellent prediction capability explaining 81% of the observed variation in extractable Al content and was comparable to that of MIR (R2 = 0.86). However, models for pH and Mehlich-3 exchangeable Ca exhibited R2 values of 0.74 and 0.79 respectively and thus had moderate predictive accuracy, compared to MIR alone with R2 values of 0.82 and 0.84 respectively. Both MIR and TXRF methods predicted soil properties that relate to nutrient

  3. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, T., E-mail: tmc@servidor.unam.m [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico D.F. 04510 (Mexico); Lartigue, J. [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico, D.F. 04510 (Mexico); Zarazua, G.; Avila-Perez, P. [National Institute of Nuclear Research. Ocoyoacac, Edo. de Mexico, 05045 (Mexico); Navarrete, M. [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico, D.F. 04510 (Mexico); Tejeda, S. [National Institute of Nuclear Research. Ocoyoacac, Edo. de Mexico, 05045 (Mexico)

    2010-06-15

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO{sub 3} and H{sub 2}O{sub 2} (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different ({alpha} = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 {mu}g g{sup -1}. A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of 'Citrus Leaves' and a blank were treated in the same way.

  4. Total protein analysis as a reliable loading control for quantitative fluorescent Western blotting.

    Directory of Open Access Journals (Sweden)

    Samantha L Eaton

    Full Text Available Western blotting has been a key technique for determining the relative expression of proteins within complex biological samples since the first publications in 1979. Recent developments in sensitive fluorescent labels, with truly quantifiable linear ranges and greater limits of detection, have allowed biologists to probe tissue specific pathways and processes with higher resolution than ever before. However, the application of quantitative Western blotting (QWB to a range of healthy tissues and those from degenerative models has highlighted a problem with significant consequences for quantitative protein analysis: how can researchers conduct comparative expression analyses when many of the commonly used reference proteins (e.g. loading controls are differentially expressed? Here we demonstrate that common controls, including actin and tubulin, are differentially expressed in tissues from a wide range of animal models of neurodegeneration. We highlight the prevalence of such alterations through examination of published "-omics" data, and demonstrate similar responses in sensitive QWB experiments. For example, QWB analysis of spinal cord from a murine model of Spinal Muscular Atrophy using an Odyssey scanner revealed that beta-actin expression was decreased by 19.3±2% compared to healthy littermate controls. Thus, normalising QWB data to β-actin in these circumstances could result in 'skewing' of all data by ∼20%. We further demonstrate that differential expression of commonly used loading controls was not restricted to the nervous system, but was also detectable across multiple tissues, including bone, fat and internal organs. Moreover, expression of these "control" proteins was not consistent between different portions of the same tissue, highlighting the importance of careful and consistent tissue sampling for QWB experiments. Finally, having illustrated the problem of selecting appropriate single protein loading controls, we demonstrate

  5. Application of the Total Reflection X-ray Fluorescence technique to trace elements determination in tobacco

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2008-01-01

    Many studies have identified an important number of toxic elements along with organic carcinogen molecules and radioactive isotopes in tobacco. In this work we have analyzed by Total Reflection X-Ray Fluorescence 9 brands of cigarettes being manufactured and distributed in the Mexican market. Two National Institute of Standards and Technology standards and a blank were equally treated at the same time. Results show the presence of some toxic elements such as Pb and Ni. These results are compared with available data for some foreign brands, while their implications for health are discussed. It can be confirmed that the Total Reflection X-Ray Fluorescence method provides precise (reproducible) and accuracy (trueness) data for 15 elements concentration in tobacco samples

  6. Application of the Total Reflection X-ray Fluorescence technique to trace elements determination in tobacco

    Science.gov (United States)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2008-12-01

    Many studies have identified an important number of toxic elements along with organic carcinogen molecules and radioactive isotopes in tobacco. In this work we have analyzed by Total Reflection X-Ray Fluorescence 9 brands of cigarettes being manufactured and distributed in the Mexican market. Two National Institute of Standards and Technology standards and a blank were equally treated at the same time. Results show the presence of some toxic elements such as Pb and Ni. These results are compared with available data for some foreign brands, while their implications for health are discussed. It can be confirmed that the Total Reflection X-Ray Fluorescence method provides precise (reproducible) and accuracy (trueness) data for 15 elements concentration in tobacco samples.

  7. Generally Applicable Transformation Protocols for Fluorescent Nanodiamond Internalization into Cells

    NARCIS (Netherlands)

    Hemelaar, Simon R; van der Laan, Kiran J; Hinterding, Sophie R; Koot, Manon V; Ellermann, Else; Perona-Martinez, Felipe P; Roig, David; Hommelet, Severin; Novarina, Daniele; Takahashi, Hiroki; Chang, Michael; Schirhagl, Romana

    2017-01-01

    Fluorescent nanodiamonds (FNDs) are promising nanoprobes, owing to their stable and magnetosensitive fluorescence. Therefore they can probe properties as magnetic resonances, pressure, temperature or strain. The unprecedented sensitivity of diamond defects can detect the faint magnetic resonance of

  8. Abstracts of the 8th Conference on total reflection x-ray fluorescence analysis and related methods

    International Nuclear Information System (INIS)

    Wobrauschek, P.

    2000-01-01

    The 8. conference on total reflection x-ray fluorescence analysis and related methods held from 25.9 to 29.9.2000 contains 79 abstracts about x-ray fluorescence analysis (XRFA) as a powerful tool used for industrial production, geological prospecting and for environmental control. Total reflection x-ray fluorescence spectroscopy is also a tool used for chemical analysis in medicine, industry and research. (E.B.)

  9. Applications of total reflection X-ray fluorescence in multi-element analysis

    International Nuclear Information System (INIS)

    Michaelis, W.; Prange, A.; Knoth, J.

    1985-01-01

    Although Total Reflection X-Ray Fluorescence Analysis (TXRF) became available for practical applications and routine measurements only few years ago, the number of programmes that make use of this method is increasing rapidly. The scope of work is widespread over environmental research and monitoring, mineralogy, mineral exploration, oceanography, biology, medicine and biochemistry. The present paper gives a brief survey of these applications and summarizes some of them which are typical for quite different matrices. (orig.)

  10. Synchrotron radiation total reflection X-ray fluorescence (SR-TXRF) for evaluation of food contamination

    International Nuclear Information System (INIS)

    Vives, A.E.S.; Brienza, S.M.B.; Moreira, S.; Zucchi, O.L.A.; Nascimento Filho, V.F.

    2006-01-01

    The objective of this study was to use synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF) for the determination of metals and other elements in food available to the population in commercial establishments, in order to evaluate the risks of contamination by these products. The analyzed species were vegetables, leafy vegetables, fruits, cereal and grain. The results indicated that some species were contaminated by Cr, Cu, Zn and Pb with concentrations much higher than the reference values. (author)

  11. Total reflection X-ray fluorescence analysis with synchrotron radiation monochromatized by multilayer structures

    International Nuclear Information System (INIS)

    Rieder, R.; Wobrauschek, P.; Ladisich, W.; Streli, C.; Aiginger, H.; Garbe, S.; Gaul, G.; Knoechel, A.; Lechtenberg, F.

    1995-01-01

    To achieve lowest detection limits in total reflection X-ray fluorescence analysis (TXRF) synchrotron radiation has been monochromatized by a multilayer structure to obtain a relative broad energy band compared to Bragg single crystals for an efficient excitation. The energy has been set to 14 keV, 17.5 keV, 31 keV and about 55 keV. Detection limits of 20 fg and 150 fg have been achieved for Sr and Cd, respectively. ((orig.))

  12. Nonimaging light concentration using total internal reflection films.

    Science.gov (United States)

    Ouellette, G; Waltham, C E; Drees, R M; Poon, A; Schubank, R; Whitehead, L A

    1992-05-01

    We present a method of fabricating nonimaging light concentrators from total internal reflection film. A prototype has been made and tested and found to operate in agreement with predictions of ray-tracing codes. The performance of the prototype is comparable with that of concentrators made from specular reflecting materials.

  13. Internal Logistics System Selection with Total Cost of Ownership Analysis

    Science.gov (United States)

    Araújo, Inês; Pimentel, Carina; Godina, Radu; Matias, João C. O.

    2017-06-01

    In this paper a methodology was followed in order to support the decision-making of one industrial unit regarding its internal logistics system. The addressed factory was facing issues with their internal logistics approach. Some alternatives were pointed out and a proper total cost of ownership (TCO) analysis was developed. This analysis was taken in order to demonstrate the more cost-effective solution for the internal logistics system. This tool is more and more valued by the companies, due to their willing to reduce the costs that are associated with the way of doing business. Despite the proposal of the best choice for the internal logistics system of the enterprise, this study also intends to present some conclusions about the match between the nature of the industrial unit and the logistics systems that best fit the requirements of those.

  14. Multielemental analysis in Brazilian cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Serpa, Renata F.B.; Jesus, Edgar F.O. de; Lopes, Ricardo T.; Moreira, Silvana

    2005-01-01

    In order to identify major and trace elements in conventional and light Brazilian cigarettes, Total Reflection X-Ray Fluorescence with Synchrotron Radiation (SR-TXRF) was used. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. This technique enables detection limit is in the ngg -1 range, which is very useful in elemental tobacco smoke analysis, since it presents most of its elements at a trace level. The major elements identified in tobacco samples were: S, Cl, K, Ca, Mn, Fe and Cd, and the trace elements were: Ti, Cr, Ni, Cu, Zn, Br, Rb, Sr and Ba. However in tobacco smoke samples, there were only two major elements: K and Ca, the others were present a trace level. The rate transfer of tobacco to tobacco smoke was about 2.5 % for all elements studied. (author)

  15. Trace elements determination in red and white wines using total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Anjos, M.J.; Lopes, R.T.; Jesus, E.F.O. de; Moreira, S.; Barroso, R.C.; Castro, C.R.F.

    2003-01-01

    Several wines produced in different regions from south of Brazil and available in markets in Rio de Janeiro were analyzed for their contents of elements such as: P, S, Cl, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Rb and Sr. Multi-element analysis was possible with simple sample preparation and subsequent analysis by total-reflection X-ray fluorescence using synchrotron radiation. The measurement was carried at the X-ray fluorescence beamline in the Synchrotron Light Source Laboratory in Campinas, Brazil. The levels of the various elements obtained were lower in the Brazilian wines than the values generally found in the literature. The present study indicates the capability of multi-element analysis for determining the contents of various elements present in wines coming from Brazil vineyards by using a simple, sensitive and precise method

  16. Single particle transfer for quantitative analysis with total-reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Esaka, Fumitaka; Esaka, Konomi T.; Magara, Masaaki; Sakurai, Satoshi; Usuda, Shigekazu; Watanabe, Kazuo

    2006-01-01

    The technique of single particle transfer was applied to quantitative analysis with total-reflection X-ray fluorescence (TXRF) spectrometry. The technique was evaluated by performing quantitative analysis of individual Cu particles with diameters between 3.9 and 13.2 μm. The direct quantitative analysis of the Cu particle transferred onto a Si carrier gave a discrepancy between measured and calculated Cu amounts due to the absorption effects of incident and fluorescent X-rays within the particle. By the correction for the absorption effects, the Cu amounts in individual particles could be determined with the deviation within 10.5%. When the Cu particles were dissolved with HNO 3 solution prior to the TXRF analysis, the deviation was improved to be within 3.8%. In this case, no correction for the absorption effects was needed for quantification

  17. Determination of heavy metals in Damascus drinking water using total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bakraji, E. H.; Karajo, J.

    2000-01-01

    Total reflection x-ray fluorescence spectrometry and chemical preconcentration have applied for multi-elemental analysis of Damascus drinking water. Water was taken directly from taps of several city sectors and analyzed for the following trace elements: Ti, V, Cr, Fe, Co, Ni, Cu, Zn, Se and Pb. The detection limits were found to be in the range of 0.1 to 0.4 μg/l. The mean levels of trace elements in the Damascus drinking water were below the World Health Organization drinking water quality guidelines. (author)

  18. Synchrotron total reflection X-ray fluorescence at BL-16 microfocus beamline of Indus-2

    Energy Technology Data Exchange (ETDEWEB)

    Tiwari, M. K., E-mail: mktiwari@rrcat.gov.in; Singh, A. K., E-mail: mktiwari@rrcat.gov.in; Das, Gangadhar, E-mail: mktiwari@rrcat.gov.in; Chowdhury, Anupam, E-mail: mktiwari@rrcat.gov.in; Lodha, G. S., E-mail: mktiwari@rrcat.gov.in [Indus Synchrotrons Utilisation Division, Raja Ramanna Centre for Advanced Technology, Indore-452013 (India)

    2014-04-24

    Determination of ultra trace elements is important in many disciplines both in basic and applied sciences. Numerous applications show their importance in medical science, environmental science, materials science, food processing and semiconductor industries and in maintaining the quality control of ultra pure chemicals and reagents. We report commissioning of a synchrotron based total reflection x-ray fluorescence (TXRF) facility on the BL-16 microfocus beamline of Indus-2. This paper describes the performance of the BL-16 TXRF spectrometer and the detailed description of its capabilities through examples of measured results.

  19. Application of a portable total reflection x-ray fluorescence spectrometer to a trace elemental analysis of wines

    International Nuclear Information System (INIS)

    Kunimura, Shinsuke; Kawai, Jun

    2009-01-01

    A portable total reflection X-ray fluorescence (TXRF) spectrometer has been applied to a trace elemental analysis of wines. Sulfur, K, Mn, Fe, and Rb were detected. These five elements were quantified by using 1 ppm of Co as an internal standard. The quantified concentrations ranged from sub-ppm to several hundred ppm. Because of organic substances in wines, the scattering of the incident X-rays from the dry residues of wines becomes strong. Therefore, a high spectral background appears in TXRF spectra of wines. Because of this background, relative standard deviations of the quantified concentrations were from 4 to 28%. Although the high spectral background appeared in the TXRF spectra of the wines, a detection limit down to several tens of ppb was achieved. The present portable spectrometer can be applied to screening for trace elements in wines before an accurate and precise analysis using a large elemental analyzer. (author)

  20. Total reflection X-ray fluorescence and archaeometry: Application in the Argentinean cultural heritage

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Cristina [Comision Nacional de Energia Atomica, Av. Gral Paz 1499 (B1650KNA) San Martin, Buenos Aires (Argentina); Laboratorio de Quimica de Sistemas Heterogeneos, Facultad de Ingenieria, Universidad de Buenos Aires, P. Colon 850 (C1063ACU), Buenos Aires (Argentina)], E-mail: Cristina.Vazquez@cnea.gov.ar; Albornoz, Ana [Agencia Rio Negro Cultura, Museo de la Patagonia F.P.Moreno, Centro Civico s/n Bariloche, Rio Negro (Argentina); Hajduk, Adam [CONICET, Museo de la Patagonia F.P.Moreno, Centro Civico s/n Bariloche, Rio Negro (Argentina); Elkin, Dolores [CONICET Instituto Nacional de Antropologia y Pensamiento Latinoamericano, 3 de febrero 1378 (C1426AEL) Buenos Aires (Argentina); Custo, Graciela; Obrustky, Alba [Comision Nacional de Energia Atomica, Av. Gral Paz 1499 (B1650KNA) San Martin, Buenos Aires (Argentina)

    2008-12-15

    Archaeometry is an interdisciplinary research area involved in the development and use of scientific methods in order to answer questions concerned with the human history. In this way the knowledge of archaeological objects through advanced chemical and physical analyses permits a better preservation and conservation of the cultural heritage and also reveals materials and technologies used in the past. In this sense, analytical techniques play an important role in order to provide chemical information about cultural objects. Considering the non destructive characteristic of this study, analytical techniques must be adequate in order to prevent any alteration or damage and in addition to allow the conservation of their integrity. Taking into account the irreplaceable character of the archaeological and artistic materials considered in this study, analytical techniques must be adequate in order to prevent any alteration or damage and in addition to allow the conservation of their integrity. Total Reflection X-ray Fluorescence Spectrometry as a geometric variant of conventional X-ray fluorescence is a proved microanalytical technique considering the small amount of sample required for the analysis. A few micrograms are enough in order to reveal valuable information about elemental composition and in this context it is highly recommended for artwork studies. In this paper a case study is presented in which Total Reflection X-Ray Fluorescence Spectrometry has been successfully employed in the archaeometry field. Examples from Argentinean cultural heritage sites related with the determination of pigments in paintings on canvas and in rock sites as well as in underwater archaeology research are shown.

  1. Dual economies and international total factor productivity differences

    DEFF Research Database (Denmark)

    Chanda, Areendam; Dalgaard, Carl-Johan Lars

    2008-01-01

    This paper provides a framework that decomposes aggregate total factor productivity (TFP) into a component reflecting relative efficiency across sectors, and another component that reflects the absolute level of efficiency. A development accounting analysis suggests that as much as 85......% of the international variation in aggregate TFP can be attributed to variation in relative efficiency across sectors. Estimation results show that recent findings highlighting the importance of strong protection of property rights, financial development and geographical advantage for the level of TFP, can be explained...

  2. Quantification of total phosphorothioate in bacterial DNA by a bromoimane-based fluorescent method.

    Science.gov (United States)

    Xiao, Lu; Xiang, Yu

    2016-06-01

    The discovery of phosphorothioate (PT) modifications in bacterial DNA has challenged our understanding of conserved phosphodiester backbone structure of cellular DNA. This exclusive DNA modification in bacteria is not found in animal cells yet, and its biological function in bacteria is still poorly understood. Quantitative information about the bacterial PT modifications is thus important for the investigation of their possible biological functions. In this study, we have developed a simple fluorescence method for selective quantification of total PTs in bacterial DNA, based on fluorescent labeling of PTs and subsequent release of the labeled fluorophores for absolute quantification. The method was highly selective to PTs and not interfered by the presence of reactive small molecules or proteins. The quantification of PTs in an E. coli DNA sample was successfully achieved using our method and gave a result of about 455 PTs per million DNA nucleotides, while almost no detectable PTs were found in a mammalian calf thymus DNA. With this new method, the content of phosphorothioate in bacterial DNA could be successfully quantified, serving as a simple method suitable for routine use in biological phosphorothioate related studies. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Elemental concentration analysis in prostate tissues using total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Leitão, R.G.; Palumbo, A.; Souza, P.A.V.R.; Pereira, G.R.; Canellas, C.G.L.; Anjos, M.J.; Nasciutti, L.E.; Lopes, R.T.

    2014-01-01

    Prostate cancer (PCa) currently represents the second most prevalent malignant neoplasia in men, representing 21% of all cancer cases. Benign Prostate Hyperplasia (BPH) is an illness prevailing in men above the age of 50, close to 90% after the age of 80. The prostate presents a high zinc concentration, about 10-fold higher than any other body tissue. In this work, samples of human prostate tissues with cancer, BPH and normal tissue were analyzed utilizing total reflection X-ray fluorescence spectroscopy using synchrotron radiation technique (SR-TXRF) to investigate the differences in the elemental concentrations in these tissues. SR-TXRF analyses were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, São Paulo. It was possible to determine the concentrations of the following elements: P, S, K, Ca, Fe, Cu, Zn and Rb. By using Mann–Whitney U test it was observed that almost all elements presented concentrations with significant differences (α=0.05) between the groups studied. - Highlights: ► Prostate cancer is the most frequently diagnosed form of cancer in men. ► Intracellular Zn is correlated with proliferation, differentiation, or apoptosis. ► The prostate gland accumulate high concentration of Zn. ► SR-TXRF is a technique widely used in the analysis of low concentration in samples

  4. Multielemental analysis in cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Barbosa, R.F.; Anjos, M.J. dos; Jesus, E.F.O. de; Lopes, R.T.; Moreira, S.

    2008-01-01

    Full text: It is well known that trace elements have important ejects in the life processes. Some of these elements are toxic for the human even at a very low level of intake. It is known that tobacco plant easily absorbs the heavy metals from the soil, especially Cd and Ni, accumulating them in its leaves. Part of these metals are transferred from tobacco to human body where they will be accumulated and damage some organs, mainly kidneys and liver. In this way, cigarettes are responsible for the death of millions of people in the world, about one death every eight seconds. The aim of this work was to determine the elemental concentrations of ten different elements in tobacco of Brazilian cigarettes used Total Reflection X-Ray Fluorescence with Synchrotron Radiation method. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. A qualitative analysis of spectral peaks showed that the samples contained potassium, calcium, titanium, chromium, manganese, iron, copper, rubidium and strontium. Among these elements, calcium, potassium and iron presented the highest concentrations. There was a wide range in the elemental concentrations in the tobacco, due various factors, such as agricultural practices, soil characteristics, climatic conditions and plant varieties. Our results are in good concern with the results reported by the scientific literature

  5. Comparison of conventional and total reflection excitation geometry for fluorescence X-ray absorption spectroscopy on droplet samples

    International Nuclear Information System (INIS)

    Falkenberg, G.; Pepponi, G.; Streli, C.; Wobrauschek, P.

    2003-01-01

    X-ray absorption fine structure (XAFS) experiments in fluorescence mode have been performed in total reflection excitation geometry and conventional 45 deg. /45 deg. excitation/detection geometry for comparison. The experimental results have shown that XAFS measurements are feasible under normal total reflection X-ray fluorescence (TXRF) conditions, i.e. on droplet samples, with excitation in grazing incidence and using a TXRF experimental chamber. The application of the total reflection excitation geometry for XAFS measurements increases the sensitivity compared to the conventional geometry leading to lower accessible concentration ranges. However, XAFS under total reflection excitation condition fails for highly concentrated samples because of the self-absorption effect

  6. Impurities determination in uranium eluates by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Bellavigna, Horacio J.; Eppis, Maria R.; Ramella, Jose L.

    1999-01-01

    The chemical control of impurities in nuclear materials is indispensable in order to assure an efficient operation of the reactors. The maximum concentration admitted depends of the elements and in most cases are in the parts per billion range. Conventional analytical methods require a pre-concentration treatment of the sample and a previous separation of the matrix (uranium). This paper investigates the use of the total reflection X-ray fluorescence as an alternative methodology for the determination of impurities in nuclear materials, namely K, Ca, Ti, Cr, Mn, Fe, Ni, Cu and As. The detection limits obtained were in the range of 0.1 to 20 ng/ml for a 1000 seconds counting time. (author)

  7. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    International Nuclear Information System (INIS)

    Vives, Ana Elisa Sirito de

    2005-01-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g -1 (Rb), respectively. (author)

  8. Recent trends in total reflection X-ray fluorescence spectrometry for biological applications

    International Nuclear Information System (INIS)

    Szoboszlai, Norbert; Polgari, Zsofia; Mihucz, Victor G.; Zaray, Gyula

    2009-01-01

    This review is focused on the application of total reflection X-ray fluorescence (TXRF) spectrometry in the field of biological research. In the last decade, most papers were published by authors who applied laboratory-scale TXRF equipments. The application of synchrotron radiation as excitation source (SR-TXRF) shows a slowly increasing tendency. In the cited papers the micro-, trace and multielement capability of these TXRF techniques was demonstrated in the clinical and medical laboratory practice, as well as in various plant physiological studies. For speciation of elements in biological matrices, the TXRF was used as element specific detector following an off-line separation step (e.g., thin layer chromatography, high performance liquid chromatography), however, these off-line methods are not competitive with the on-line coupled HPLC-inductively coupled plasma mass spectrometry

  9. Total-reflection X-ray fluorescence: An alternative tool for the analysis of magnetic ferrofluids

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, R. [Servicio Interdepartamental de Investigacion (SIdI), Facultad de Ciencias, Universidad Autonoma de Madrid, Cantoblanco, E-28049, Madrid (Spain)], E-mail: ramon.fernandez@uam.es; Costo, R.; Morales, M.P.; Bomati-Miguel, O.; Veintemillas-Verdaguer, S. [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, E-28049, Madrid (Spain)

    2008-12-15

    This work presents the first application of the total-reflection X-ray fluorescence (TXRF) to the compositional study of magnetic ferrofluids. With the aims of validating the best analytical conditions and also, limitations of the TXRF in the compositional study of these materials, an alternative empirical method, based in the use of angle-dependence TXRF (AD-TXRF) measurements, is proposed. Three kinds of ferromagnetic nanoparticles, with different morphologies, have been studied. The techniques of inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectroscopy (ICP-OES) have been used to validate the TXRF results. In contrast with the plasma techniques, the developed TXRF procedure need not of previous chemical acid digestion. Additionally, two procedures of magnetic nanoparticles synthesis, co-precipitation and laser-pyrolysis, have been checked for the contaminants trace metals Zn, Mn and Cr. It has been found that the method of laser-pyrolysis produces nanoparticles of higher purity.

  10. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  11. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Brienza, Sandra Maria Boscolo [ Universidade Metodista de Piracicaba (UNIMEP), Piracicaba, SP (Brazil). Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: virgilio@cena.usp.br

    2005-07-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g{sup -1} (Rb), respectively. (author)

  12. Total-reflection x-ray fluorescence with a brillant undulator x-ray source

    International Nuclear Information System (INIS)

    Sakurai, K.; Eba, H.; Numako, C.; Suzuki, M.; Inoue, K.; Yagi, N.

    2000-01-01

    Total-reflection x-ray fluorescence (TXRF) is a highly sensitive technique for analyzing trace elements, because of the very low background from the sample support. Use of third-generation synchrotron x-ray source could further enhance the detection power. However, while such high sensitivity permits the detection of signals from trace elements of interest, it also means that one can observe weak parasitic x-rays as well. If the sample surface becomes even slightly contaminated, owing to air particulates near the beamline, x-ray fluorescence lines of iron, zinc, copper, nickel, chromium, and titanium can be observed even for a blank sample. Another critical problem is the low-energy-side tail of the scattering x-rays, which ultimately restricts the detection capability of the technique using a TXRF spectrometer based on a Si(Li) detector. The present paper describes our experiments with brilliant undulator x-ray beams at BL39XU and BL40XU, at the SPring-8, Harima, Japan. The emphasis is on the development of instruments to analyze a droplet of 0.1 μl containing trace elements of ppb level. Although the beamline is not a clean room, we have employed equipment for preparing a clean sample and also for avoiding contamination during transferring the sample into the spectrometer. We will report on the successful detection of the peak from 0.8 ppb selenium in a droplet (absolute amount 80 fg). We will also present the results of recent experiments obtained from a Johansson spectrometer rather than a Si(Li) detector. (author)

  13. Generally Applicable Transformation Protocols for Fluorescent Nanodiamond Internalization into Cells.

    Science.gov (United States)

    Hemelaar, Simon R; van der Laan, Kiran J; Hinterding, Sophie R; Koot, Manon V; Ellermann, Else; Perona-Martinez, Felipe P; Roig, David; Hommelet, Severin; Novarina, Daniele; Takahashi, Hiroki; Chang, Michael; Schirhagl, Romana

    2017-07-19

    Fluorescent nanodiamonds (FNDs) are promising nanoprobes, owing to their stable and magnetosensitive fluorescence. Therefore they can probe properties as magnetic resonances, pressure, temperature or strain. The unprecedented sensitivity of diamond defects can detect the faint magnetic resonance of a single electron or even a few nuclear spins. However, these sensitivities are only achieved if the diamond probe is close to the molecules that need to be detected. In order to utilize its full potential for biological applications, the diamond particle has to enter the cell. Some model systems, like HeLa cells, readily ingest particles. However, most cells do not show this behavior. In this article we show for the first time generally applicable methods, which are able to transport fluorescent nanodiamonds into cells with a thick cell wall. Yeast cells, in particular Saccharomyces cerevisiae, are a favored model organism to study intracellular processes including aging on a cellular level. In order to introduce FNDs in these cells, we evaluated electrical transformation and conditions of chemical permeabilization for uptake efficiency and viability. 5% DMSO (dimethyl sulfoxide) in combination with optimized chemical transformation mix leads to high uptake efficiency in combination with low impact on cell biology. We have evaluated all steps in the procedure.

  14. TX 2000: total reflection and 45o energy dispersive x-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Pasti, F.; Torboli, A.; Valdes, M.

    2000-01-01

    This equipment, developed by Ital Structures, combines two kinds of energy dispersive X-ray fluorescence techniques, the first using total reflection geometry and the second conventional 45 o geometry. The equipment is completely controlled by a PC and to reach the condition of total reflection is very easy because it is enough to load the file with the right position for the corresponding energy. In this apparatus we used an x-ray tube with an alloy anode of Mo/W with a long fine focus at 2200 W. To monochromatize the x-ray beam while choosing, for example, the Mo K alpha or W L alpha or a piece of white spectrum of 33 keV, we use a highly reflective multilayer made of Si/W with 2d = 45.5 A o . The detector used in the equipment is a lithium drifted silicon detector (Si(Li)) with an excellent energy resolution of 135 eV at 5.9 keV and 1000 cps. We developed two programs written in Windows 95, 98 and NT for a 32 bit microprocessor. The first one is called TYACQ32 and has the following functions: first, complete control of the hardware, second automatic alignment of the TX 2000 spectrometer and third acquisition of spectra. The second program is EDXRF32. This is a program to accomplish spectrum and quantitative analysis for TXRF and EDXRF 45 o degrees analysis. (author)

  15. Total Reflection X-ray Fluorescence attachment module modified for analysis in vacuum

    International Nuclear Information System (INIS)

    Wobrauschek, P.; Streli, C.; Kregsamer, P.; Meirer, F.; Jokubonis, C.; Markowicz, A.; Wegrzynek, D.; Chinea-Cano, E.

    2008-01-01

    Based on the design of the low cost Total Reflection X-Ray Fluorescence attachment module available since 1986 from Atominstitut (WOBRAUSCHEK-module) which can be attached to existing X-ray equipment, a new version was developed which allows the analysis of samples in vacuum. This design was in particular possible as the Peltier cooled light weight Silicon Drift Detector is following all adjustment procedures for total reflection as angle rotation and linear motion. The detector is mounted through a vacuum feed and O-ring tightening to the small vacuum chamber. The standard 30 mm round quartz, Si-wafer or Plexiglas reflectors are used to carry the samples. The reflectors are placed on the reference plane with the dried sample down looking facing in about 0.5 mm distance the up looking detector window. The reflectors are resting on 3 steel balls defining precisely the reference plane for the adjustment procedure. As the rotation axis of the module is in the plane of the reflector surface, angle dependent experiments can be made to distinguish between film and particulate type contamination of samples. Operating with a Mo anode at 50 kV and 40 mA with a closely attached multilayer monochromator and using a 10 mm 2 KETEK silicon drift detector with 8 μm Be window, a sensitivity of 70 cps/ng for Rb was measured and detection limits of 2 pg were obtained

  16. Total reflection X-ray fluorescence analysis of river waters in its stream across the city of Cordoba, in Argentina

    International Nuclear Information System (INIS)

    Valentinuzzi, M.C.; Sanchez, H.J.; Abraham, J.

    2006-01-01

    The aim of this work was to analyze the composition of river waters and to study their quality by detecting possible contaminants. The samples were taken at 32 points of the Suquia River in its stream across the city of Cordoba (in the Province of Cordoba, Argentina). The samples were analyzed with total reflection X-ray fluorescence (TXRF) using beam guides. Beam guides made of two Si plate reflectors were used as sample carriers and to guide the X-ray photons to the sample; the measurements were taken using the characteristic configuration that ensures the best excitation and detection conditions (in TXRF). The analyses were carried out by preconcentration of the water samples and by adding an internal standard (Gallium); small amounts of samples (30 μl) were deposited on the Si reflector plate and they were then analyzed in the total reflection regime. Spectra were analyzed with standard methods using conventional programs. The results show interesting behaviors of the concentration of trace elements along the river: elements of low atomic number (such as Ca, Cl, S, K) present higher concentrations as compared to high Z elements (such as Fe, Zn, Br, Sr); the concentrations of light elements follow a similar behavior along the stream, the same situation is observed in the set of elements with high atomic number. Some samples present high concentrations in certain elements indicating possible sources of contamination

  17. Prediction of total electron content using the international reference ionosphere

    International Nuclear Information System (INIS)

    Mcnamara, L.F.

    1984-01-01

    It is pointed out that the International Reference Ionosphere (IRI) is an empirical model of the ionosphere based on experimental observations. Rawer et al. (1978) have discussed the goals and status of the IRI. The aim of the IRI is related to the establishment of a compendium of height profiles through the ionosphere for the four main parameters, taking into account plasma density, temperature of ions and electrons, and ion composition. The present model is inadequate in some areas, and the IRI working group has encouraged tests of the model's validity. The present investigation is concerned with a test of the model's ability to reproduce observations of total electron content (TEC) over a wide range of conditions. The TEC observations were obtained with the aid of the Faraday rotation technique, which provides the TEC out to about 2000 km. Tests using the Bent ionospheric model indicate that the altitude range 1000 to 2000 km contributes up to five percent of the TEC. 12 references

  18. Investigation of polyelectrolytes by total reflection x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Varga, I.; Nagy, M.

    2000-01-01

    Water soluble polyelectrolyte samples containing mono-, bi- and trivalent metal ions were investigated without any pretreatment. Acid digestion of linear polymers may lead to a product insoluble in water so the digestion has to be avoided. The aim of this paper was the determination of analytical characteristics and limitations of the total reflection x-ray fluorescence (TXRF) analysis for poly (vinylalcohol-vinylsulphate) salts and poly (acrylic acid, acrylamide) copolymers containing the following cations: K + , Cs + , Ba 2+ , Cu 2+ and La 3+ . On the basis of our results efficiency of ion-exchange during preparation of polyelectrolytes and stoichiometry of the end-product were determined. TXRF results were compared with data gained by inductively coupled plasma atomic emission spectrometry (ICP-AES) measurements except in the case of Cs + which has poor sensitivity in ICP-AES. Good agreement was found between the results of the two techniques and calculations from titrimetric data. Concentration of Li + and Mg 2+ in polymer samples was measured by ICP-AES. In majority of cases film-like dry residues of aqueous solutions of polyelectrolytes can be characterized by homogeneous spatial distribution of metal ions within the organic matrix. This is because the migration of the ions is hindered during drying process. Determination of metals in polyelectrolyte films by TXRF is quite ideal as model for analysis of plant, animal or human tissues which is a frequent task in environmental and inorganic biomedical analytical chemistry. (author)

  19. Synchrotron radiation total reflection x-ray fluorescence analysis; of polymer coated silicon wafers

    International Nuclear Information System (INIS)

    Brehm, L.; Kregsamer, P.; Pianetta, P.

    2000-01-01

    It is well known that total reflection x-ray fluorescence (TXRF) provides an efficient method for analyzing trace metal contamination on silicon wafer surfaces. New polymeric materials used as interlayer dielectrics in microprocessors are applied to the surface of silicon wafers by a spin-coating process. Analysis of these polymer coated wafers present a new challenge for TXRF analysis. Polymer solutions are typically analyzed for bulk metal contamination prior to application on the wafer using inductively coupled plasma mass spectrometry (ICP-MS). Questions have arisen about how to relate results of surface contamination analysis (TXRF) of a polymer coated wafer to bulk trace analysis (ICP-MS) of the polymer solutions. Experiments were done to explore this issue using synchrotron radiation (SR) TXRF. Polymer solutions were spiked with several different concentrations of metals. These solutions were applied to silicon wafers using the normal spin-coating process. The polymer coated wafers were then measured using the SR-TXRF instrument set-up at the Stanford Synchrotron Radiation Laboratory (SSRL). Several methods of quantitation were evaluated. The best results were obtained by developing calibration curves (intensity versus ppb) using the spiked polymer coated wafers as standards. Conversion of SR-TXRF surface analysis results (atoms/cm 2 ) to a volume related concentration was also investigated. (author)

  20. Characterization and classification of spirituous beverages by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Davila, E.G. de; Lue-Meru, M.P.; Capote, T.; Greaves, E.

    2000-01-01

    The total reflection x-ray fluorescence (TXRF) technique was applied for the multi-elemental analysis of spirituous beverages like rum, cocuy (typical spirituous beverage in Venezuela), whiskey and wine, in order to classify the samples by product processing and geographical origin by chemometric analysis. Special attention was paid to the cocuy samples, since there is a lack of quality control of this beverage, mainly due to the home-made product processing. The use of the Compton peak information was evaluated for the determination of organic content in samples. In the specifically case of cocuy samples the Compton peak area was correlated to the ash content for detection of adulteration with sugar syrup. Cocuy samples were also analyzed using gas chromatography, for pH, acidity, ash content and refractometry, in order to develop the recognition pattern. The TXRF analysis was carried out in a Canberra spectrometer, using the K α-line of a Motube, by a direct procedure previously developed. The analysis of the data was done by using principal components analysis and a confidence test. The results show that TXRF and chemometric analysis is a useful tool for quality control of spirituous beverages, not only concerning to metal content, but also in the evaluation of sugar and non volatile organic content. (author)

  1. Characterization and classification of spirituous beverages by total reflection x-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Davila, E.G. de [Univerisdad Centroccidental Lisandro Alvarado, Decanato de Agronomia, Dpto. de Quimica y Suelos. Nucleo Tarabana, cabudare, Edo. Lara (Venezuela); Lue-Meru, M P; Capote, T [Univerisdad Centroccidental Lisandro Alvarado, Decanato de Agronomia, Dpto. de Quimica y Suelos. Nucleo Tarabana, Cabudare, Edo. Lara (Venezuela); Universidad Simon Bolivar, Dpto. de Quimica, Lab. Espectroscopia Atomica, Sartenejas, Baruta, Edo. Miranda (Venezuela); Greaves, E [Universidad Simon Bolivar, Dpto. de Fisica, Sartenejas, Baruta, Edo. Miranda (Venezuela)

    2000-07-01

    The total reflection x-ray fluorescence (TXRF) technique was applied for the multi-elemental analysis of spirituous beverages like rum, cocuy (typical spirituous beverage in Venezuela), whiskey and wine, in order to classify the samples by product processing and geographical origin by chemometric analysis. Special attention was paid to the cocuy samples, since there is a lack of quality control of this beverage, mainly due to the home-made product processing. The use of the Compton peak information was evaluated for the determination of organic content in samples. In the specifically case of cocuy samples the Compton peak area was correlated to the ash content for detection of adulteration with sugar syrup. Cocuy samples were also analyzed using gas chromatography, for pH, acidity, ash content and refractometry, in order to develop the recognition pattern. The TXRF analysis was carried out in a Canberra spectrometer, using the K {alpha}-line of a Motube, by a direct procedure previously developed. The analysis of the data was done by using principal components analysis and a confidence test. The results show that TXRF and chemometric analysis is a useful tool for quality control of spirituous beverages, not only concerning to metal content, but also in the evaluation of sugar and non volatile organic content. (author)

  2. Total reflection X-ray Fluorescence determination of interfering elements rubidium and uranium by profile fitting

    Science.gov (United States)

    Dhara, Sangita; Khooha, Ajay; Singh, Ajit Kumar; Tiwari, M. K.; Misra, N. L.

    2018-06-01

    Systematic studies to assess the analytical parameters obtained in the total reflection X-ray fluorescence (TXRF) determinations of interfering elements Rb and U using profile fitting are reported in the present manuscript. The X-ray lines Rb Kα and U Lα having serious spectral interference (ΔE = 218 eV), have been used as analytical lines. The intensities of these X-ray lines have been assessed using profile fitting. In order to compare the analytical results of Rb determinations in presence of U, with and without U excitation, synchrotron radiation was tuned to energy just above and below the U Labs edge. This approach shall excite both Rb Kα and U Lα simultaneously and Rb Kα selectively. Finally, the samples were also analyzed with a laboratory based TXRF spectrometer. The analytical results obtained in all these conditions were comparable. The authenticity of the results was assessed by analyzing U with respect to Rb in Rb2U(SO4)3, a standard reference material for U. The average precision obtained for TXRF determinations was below 3% (RSD, n = 3, 1σ) and the percent deviation of TXRF values from the expected values calculated on the basis of sample preparation was within 3%.

  3. Total reflection X-ray fluorescence as a tool for food screening

    Science.gov (United States)

    Borgese, Laura; Bilo, Fabjola; Dalipi, Rogerta; Bontempi, Elza; Depero, Laura E.

    2015-11-01

    This review provides a comprehensive overview of the applications of total reflection X-ray fluorescence (TXRF) in the field of food analysis. Elemental composition of food is of great importance, since food is the main source of essential, major and trace elements for animals and humans. Some potentially toxic elements, dangerous for human health may contaminate food, entering the food chain from the environment, processing, and storage. For this reason the elemental analysis of food is fundamental for safety assessment. Fast and sensitive analytical techniques, able to detect major and trace elements, are required as a result of the increasing demand on multi-elemental information and product screening. TXRF is suitable for elemental analysis of food, since it provides simultaneous multi-elemental identification in a wide dynamic range of concentrations. Several different matrices may be analyzed obtaining results with a good precision and accuracy. In this review, the most recent literature about the use of TXRF for the analysis of food is reported. The focus is placed on the applications within food quality monitoring of drinks, beverages, vegetables, fruits, cereals, animal derivatives and dietary supplements. Furthermore, this paper provides a critical outlook on the developments required to transfer these methods from research to the industrial and analytical laboratories contexts.

  4. Sample preparation for total reflection X-ray fluorescence analysis using resist pattern technique

    Science.gov (United States)

    Tsuji, K.; Yomogita, N.; Konyuba, Y.

    2018-06-01

    A circular resist pattern layer with a diameter of 9 mm was prepared on a glass substrate (26 mm × 76 mm; 1.5 mm thick) for total reflection X-ray fluorescence (TXRF) analysis. The parallel cross pattern was designed with a wall thickness of 10 μm, an interval of 20 μm, and a height of 1.4 or 0.8 μm. This additional resist layer did not significantly increase background intensity on the XRF peaks in TXRF spectra. Dotted residue was obtained from a standard solution (10 μL) containing Ti, Cr, Ni, Pb, and Ga, each at a final concentration of 10 ppm, on a normal glass substrate with a silicone coating layer. The height of the residue was more than 100 μm, where self-absorption in the large residue affected TXRF quantification (intensity relative standard deviation (RSD): 12-20%). In contrast, from a droplet composed of a small volume of solution dropped and cast on the resist pattern structure, the obtained residue was not completely film but a film-like residue with a thickness less than 1 μm, where self-absorption was not a serious problem. In the end, this sample preparation was demonstrated to improve TXRF quantification (intensity RSD: 2-4%).

  5. Synchrotron Radiation Total Reflection X-ray Fluorescence Spectroscopy for Microcontamination Analysis on Silicon Wafer Surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Takaura, Norikatsu

    1997-10-01

    As dimensions in state-of-the-art CMOS devices shrink to less than 0.1 pm, even low levels of impurities on wafer surfaces can cause device degradation. Conventionally, metal contamination on wafer surfaces is measured using Total Reflection X-Ray Fluorescence Spectroscopy (TXRF). However, commercially available TXRF systems do not have the necessary sensitivity for measuring the lower levels of contamination required to develop new CMOS technologies. In an attempt to improve the sensitivity of TXRF, this research investigates Synchrotron Radiation TXRF (SR TXRF). The advantages of SR TXRF over conventional TXRF are higher incident photon flux, energy tunability, and linear polarization. We made use of these advantages to develop an optimized SR TXRF system at the Stanford Synchrotron Radiation Laboratory (SSRL). The results of measurements show that the Minimum Detection Limits (MDLs) of SR TXRF for 3-d transition metals are typically at a level-of 3x10{sup 8} atoms/cm{sup 2}, which is better than conventional TXRF by about a factor of 20. However, to use our SR TXRF system for practical applications, it was necessary to modify a commercially available Si (Li) detector which generates parasitic fluorescence signals. With the modified detector, we could achieve true MDLs of 3x10{sup 8} atoms/cm{sup 2} for 3-d transition metals. In addition, the analysis of Al on Si wafers is described. Al analysis is difficult because strong Si signals overlap the Al signals. In this work, the Si signals are greatly reduced by tuning the incident beam energy below the Si K edge. The results of our measurements show that the sensitivity for Al is limited by x-ray Raman scattering. Furthermore, we show the results of theoretical modeling of SR TXRF backgrounds consisting of the bremsstrahlung generated by photoelectrons, Compton scattering, and Raman scattering. To model these backgrounds, we extended conventional theoretical models by taking into account several aspects particular

  6. Total reflection X-ray fluorescence as a convenient tool for determination of trace elements in microscale gasoline and diesel

    Science.gov (United States)

    Zhang, Airui; Jin, Axiang; Wang, Hai; Wang, Xiaokang; Zha, Pengfei; Wang, Meiling; Song, Xiaoping; Gao, Sitian

    2018-03-01

    Quantitative determination of trace elements like S, Fe, Cu, Mn and Pb in gasoline and S in diesel is of great importance due to the growing concerns over air pollution, human health and engine failure caused by utilization of gasoline and diesel with these harmful elements. A method of total reflection X-ray fluorescence (TXRF) was developed to measure these harmful trace elements in gasoline and diesel. A variety of factors to affect measurement results, including TXRF parameters, microwave-assisted digestion conditions and internal standard element and its addition, were examined to optimize these experimental procedures. The hydrophobic treatment of the surface of quartz reflectors to support the analyte with neutral silicone solutions could prepare thin films of gasoline and diesel digestion solutions for subsequent TXRF analysis. The proposed method shows good potential and reliability to determine the content of harmful trace elements in gasoline and diesel with high sensitivity and accuracy without drawing different standard calibration curves, and can be easily employed to screen gasoline and diesel in routine quality control and assurance.

  7. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Haydn [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of); Marco Parra, Lue-Meru, E-mail: luemerumarco@yahoo.e [Universidad Centroccidental Lisandro Alvarado, Dpto. Quimica y Suelos, Decanato de Agronomia, Tarabana, Cabudare, Edo.Lara (Venezuela, Bolivarian Republic of); Bennun, Leonardo [Universidad de Concepcion, Concepcion (Chile); Greaves, Eduardo D. [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of)

    2010-06-15

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-K{alpha} and Co-K{alpha} lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 {mu}gL{sup -1}. The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  8. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    International Nuclear Information System (INIS)

    Barros, Haydn; Marco Parra, Lue-Meru; Bennun, Leonardo; Greaves, Eduardo D.

    2010-01-01

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-Kα and Co-Kα lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 μgL -1 . The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  9. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy

    International Nuclear Information System (INIS)

    Zarazua O, G.; Carapia M, L.

    2000-01-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  10. Development of off-line layer chromatographic and total reflection X-ray fluorescence spectrometric methods for arsenic speciation

    Energy Technology Data Exchange (ETDEWEB)

    Mihucz, Victor G. [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary); Moricz, Agnes M. [L. Eoetvoes University, Department of Chemical Technology and Environmental Chemistry, P.O. Box 32, H-1518 Budapest (Hungary); Kroepfl, Krisztina [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Szikora, Szilvia [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Tatar, Eniko [Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary); L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary); Parra, Lue Meru Marco [Universidad Centro-occidental Lisandro Alvarado, Decanato de Agronomia, Departamento de Quimica y Suelos Unidad de Analisis Instrumental, Apartado Postal 4076, Cabudare 3023 (Venezuela); Zaray, Gyula [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary) and Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary) and L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary)]. E-mail: zaray@ludens.elte.hu

    2006-11-15

    Rapid and low cost off-line thin layer chromatography-total reflection X-ray fluorescence spectrometry and overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods have been developed for separation of 25 ng of each As(III), As(V), monomethyl arsonic acid and dimethylarsinic acid applying a PEI cellulose stationary phase on plastic sheets and a mixture of acetone/acetic acid/water = 2:1:1 (v/v/v) as eluent system. The type of eluent systems, the amounts (25-1000 ng) of As species applied to PEI cellulose plates, injection volume, development distance, and flow rate (in case of overpressured thin layer chromatography) were taken into consideration for the development of the chromatographic separation. Moreover, a microdigestion method employing nitric acid for the As spots containing PEI cellulose scratched from the developed plates divided into segments was developed for the subsequent total reflection X-ray fluorescence spectrometry analysis. The method was applied for analysis of root extracts of cucumber plants grown in As(III) containing modified Hoagland nutrient solution. Both As(III) and As(V) were detected by applying the proposed thin layer chromatography/overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods.

  11. Development of off-line layer chromatographic and total reflection X-ray fluorescence spectrometric methods for arsenic speciation

    International Nuclear Information System (INIS)

    Mihucz, Victor G.; Moricz, Agnes M.; Kroepfl, Krisztina; Szikora, Szilvia; Tatar, Eniko; Parra, Lue Meru Marco; Zaray, Gyula

    2006-01-01

    Rapid and low cost off-line thin layer chromatography-total reflection X-ray fluorescence spectrometry and overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods have been developed for separation of 25 ng of each As(III), As(V), monomethyl arsonic acid and dimethylarsinic acid applying a PEI cellulose stationary phase on plastic sheets and a mixture of acetone/acetic acid/water = 2:1:1 (v/v/v) as eluent system. The type of eluent systems, the amounts (25-1000 ng) of As species applied to PEI cellulose plates, injection volume, development distance, and flow rate (in case of overpressured thin layer chromatography) were taken into consideration for the development of the chromatographic separation. Moreover, a microdigestion method employing nitric acid for the As spots containing PEI cellulose scratched from the developed plates divided into segments was developed for the subsequent total reflection X-ray fluorescence spectrometry analysis. The method was applied for analysis of root extracts of cucumber plants grown in As(III) containing modified Hoagland nutrient solution. Both As(III) and As(V) were detected by applying the proposed thin layer chromatography/overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods

  12. Censoring: a new approach for detection limits in total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Pajek, M.; Kubala-Kukus, A.; Braziewicz, J.

    2004-01-01

    It is shown that the detection limits in the total-reflection X-ray fluorescence (TXRF), which restrict quantification of very low concentrations of trace elements in the samples, can be accounted for using the statistical concept of censoring. We demonstrate that the incomplete TXRF measurements containing the so-called 'nondetects', i.e. the non-measured concentrations falling below the detection limits and represented by the estimated detection limit values, can be viewed as the left random-censored data, which can be further analyzed using the Kaplan-Meier (KM) method correcting for nondetects. Within this approach, which uses the Kaplan-Meier product-limit estimator to obtain the cumulative distribution function corrected for the nondetects, the mean value and median of the detection limit censored concentrations can be estimated in a non-parametric way. The Monte Carlo simulations performed show that the Kaplan-Meier approach yields highly accurate estimates for the mean and median concentrations, being within a few percent with respect to the simulated, uncensored data. This means that the uncertainties of KM estimated mean value and median are limited in fact only by the number of studied samples and not by the applied correction procedure for nondetects itself. On the other hand, it is observed that, in case when the concentration of a given element is not measured in all the samples, simple approaches to estimate a mean concentration value from the data yield erroneous, systematically biased results. The discussed random-left censoring approach was applied to analyze the TXRF detection-limit-censored concentration measurements of trace elements in biomedical samples. We emphasize that the Kaplan-Meier approach allows one to estimate the mean concentrations being substantially below the mean level of detection limits. Consequently, this approach gives a new access to lower the effective detection limits for TXRF method, which is of prime interest for

  13. Total reflection X-ray fluorescence analysis of airborne silver nanoparticles from fabrics.

    Science.gov (United States)

    Menzel, Magnus; Fittschen, Ursula Elisabeth Adriane

    2014-03-18

    Ag nanoparticles (NPs) are usually applied to consumer products because of their antimicrobial properties, which are desired in fabrics for sportswear as well as cloth used for cleaning. Hazards to human health from airborne Ag NPs may occur when the NPs are inhaled. NPs are comparable in size to macromolecules and viruses and able to penetrate deep into the lungs, e.g., the alveoli, where they may cause damage to cells and tissue due to their large surface area. In this study, aerosols released form fabrics treated with Ag NPs were collected using a low pressure Berner impactor and analyzed with total reflection X-ray fluorescence (TXRF). We found that the Ag NPs are released primarily in the form of larger particles, mainly 0.13-2 μm, probably attached to fiber material. Using an electron micro probe, single particles could be identified. The detection of backscattered electrons suggests small spots on the particle consist of a heavier element, which most likely is Ag, although the signal in energy-dispersive X-ray spectroscopy (EDX) was below the lower limit of detection (LOD). To achieve LODs necessary for Ag determination, Ar peaks were eliminated by a nitrogen atmosphere provided by the "Picofox-box". This enables linear calibration and quantification of Ag. The LOD was calculated at 0.2 ng (2.0 ppb). Following the TXRF and scanning electron microscopy (SEM)/EDX analysis, the aerosol samples were dissolved in nitric acid and analyzed with ICPMS to successfully confirm the results obtained by the TXRF measurements.

  14. Fundamental quantification procedure for total reflection X-ray fluorescence spectra analysis and elements determination

    International Nuclear Information System (INIS)

    Wegrzynek, D.; Holynska, B.

    1997-01-01

    A method for the determination of the concentrations of elements in particulate-like samples measured in total reflection geometry is proposed. In the proposed method the fundamental parameters are utilized for calculating the sensitivities of elements and an internal standard is used to account for the unknown mass per unit area of a sample and geometrical constant of the spectrometer. The modification of the primary excitation spectrum on its way to a sample has been taken into consideration. The concentrations of the elements to be determined are calculated simultaneously with the spectra deconvolution procedure. In the process of quantitative analysis the intensities of all X-ray peaks corresponding to K and L-series lines present in the analyzed spectrum are taken into account. (Author)

  15. Homogeneous plate based antibody internalization assay using pH sensor fluorescent dye.

    Science.gov (United States)

    Nath, Nidhi; Godat, Becky; Zimprich, Chad; Dwight, Stephen J; Corona, Cesear; McDougall, Mark; Urh, Marjeta

    2016-04-01

    Receptor-mediated antibody internalization is a key mechanism underlying several anti-cancer antibody therapeutics. Delivering highly toxic drugs to cancer cells, as in the case of antibody drug conjugates (ADCs), efficient removal of surface receptors from cancer cells and changing the pharmacokinetics profile of the antibody drugs are some of key ways that internalization impacts the therapeutic efficacy of the antibodies. Over the years, several techniques have been used to study antibody internalization including radiolabels, fluorescent microscopy, flow cytometry and cellular toxicity assays. While these methods allow analysis of internalization, they have limitations including a multistep process and limited throughput and are generally endpoint assays. Here, we present a new homogeneous method that enables time and concentration dependent measurements of antibody internalization. The method uses a new hydrophilic and bright pH sensor dye (pHAb dye), which is not fluorescent at neutral pH but becomes highly fluorescent at acidic pH. For receptor mediated antibody internalization studies, antibodies against receptors are conjugated with the pHAb dye and incubated with the cells expressing the receptors. Upon binding to the receptor, the dyes conjugated to the antibody are not fluorescent because of the neutral pH of the media, but upon internalization and trafficking into endosomal and lysosomal vesicles the pH drops and dyes become fluorescent. The enabling attributes of the pHAb dyes are the hydrophilic nature to minimize antibody aggregation and bright fluorescence at acidic pH which allows development of simple plate based assays using a fluorescent reader. Using two different therapeutic antibodies--Trastuzumab (anti-HER2) and Cetuximab (anti-EGFR)--we show labeling with pHAb dye using amine and thiol chemistries and impact of chemistry and dye to antibody ration on internalization. We finally present two new approaches using the pHAb dye, which will be

  16. Total reflection x-ray fluorescence spectrometers for multielemental analysis: status of commercial equipment

    International Nuclear Information System (INIS)

    Ayala Jimenez, R.E.

    2000-01-01

    Multi-elemental analysis by total reflection x-ray fluorescence spectrometry has evolved during two decades. At the present there are commercial equipment available for the chemical analysis in all kind of biological and mineral samples. The electronic industry has also been benefited from the scientific and technological developments in the field of TXRF. The basic components of the spectrometers can be summarized as follow: a) excitation source; b) geometric arrangement (optics) for collimation and monochromatization of the primary radiation; c) x-ray detector; d) hardware and software for operation of the instrument, data acquisition and spectral deconvolution to determine the concentrations of the element present in the sample (quantitative analysis). As optional there are manufacturers offering the conventional 45 degrees geometry for direct excitation of bulky liquid or solid samples. Personal communications of the author and the commercial brochures available at the moment of writing this presentation have allowed to list the following type of components used in the TXRF spectrometers for multi-elemental analysis (the devices used in the electronic industry to analyze silicon wafers are excluded). Excitation: high power x-ray tube, output from 1300 to 2000 watts; metal ceramic low power-ray tube, output up to 50 watts. Different anodes are used but molybdenum, tungsten and copper are frequent. The excitation systems can be customized according to the requirements of the laboratory. Detector: Si-Li semi-conductor liquid nitrogen cooled; silicon solid state thermoelectrically cooled (silicon drift detector SDD and Si-PIN diode). Optics: multilayer monochromator of Si-W or Ni-C; double multilayer monochromator. Electronics: spectroscopy amplifier, analog to digital converter adapted to a PC compatible computer with software in Windows environment for the whole operation of the spectrometer and for qualy/quantitative analysis of samples are standards in the

  17. Characterization of urban air pollution by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Schmeling, Martina

    2004-01-01

    Besides photochemical smog, particulate air pollution is a constantly growing problem in urban areas. The particulate matter present in pollution events contains often toxic or health impacting elements and is responsible for low visibility, might be triggering respiratory diseases like asthma, and can play an important role in formation or duration of smog events. To characterize particulate pollution in two different cities, samples were taken during intensive field campaigns in Chicago, IL, in 2002 and Phoenix, AZ, in 2001. Both cities experience regularly photochemical smog events as well as particulate pollution, but show very different meteorological and topographical conditions. Therefore it is expected that the particulate composition varies significantly, providing information about different pollution forms. Sampling took place in both cases at elevated locations and had a temporal resolution of 1.5 h and 1 h, respectively. The samples were analyzed by total reflection X-ray fluorescence after digestion of the filter matrix. As expected the elemental composition of particulate matter varied between both cities substantially with Phoenix showing a higher abundance of crustal elements, and Chicago enrichment in anthropogenically produced ones. In both cities diurnal patterns were found, exerting maxima in the morning and minima in the early afternoon. The diurnal pattern was much more regularly and also more strongly pronounced in Phoenix. Phoenix's valley location permits for a more stable nocturnal boundary layer to build up during the night thus trapping particulates efficiently during this time, until mixing occurs in the early morning hours and the residual layer lifts. In Chicago, the diurnal variation was less extreme, but another pattern determines the situation with the lake breeze. The lake breeze corresponds to a shift in wind direction towards the east, i.e. from Lake Michigan during the late morning. It was found that certain elemental species

  18. Modelling of a total reflection X-ray fluorescence (TXRF) system ...

    African Journals Online (AJOL)

    The simulation of the different stages involved in x-ray fluorescence emissions was carried out by writing a suite of computer programs using FORTRAN programming language. These computer simulated XRF stages were then integrated together to generate a general robust model which was run with the digital visual ...

  19. Total reflection X-ray fluorescence analysis of oral fluids of women affected by osteoporosis and osteopenia

    Science.gov (United States)

    Sánchez, Héctor Jorge; Valentinuzzi, María Cecilia; Grenón, Miram; Abraham, José

    2008-12-01

    Osteoporosis is a disease characterized by low bone mass and microarchitectural deterioration of bone tissue, leading to bone fragility and an increased susceptibility to fractures; the early stage of decreased bone density is called osteopenia. More than 200 million people are affected and about 50% of post-menopausic women are expected to develop the disease. Osteoporosis, osteopenia and periodontal disease have in common several risk factors, being hyperthyroidism and smoking habits the most important ones. There is scarce information in the literature about the association between periodontal disease and osteoporosis and/or osteopenia. Some works suggest that osteoporotic women are susceptible to a higher loss of periodontal insertion, alveolar bones, and teeth. Thirty adult post-menopausic women were studied; some of them were healthy (control group) and the rest of them were undergoing some stage of osteoporosis or osteopenia. All the subjects were healthy, non-smokers, not having dental implants, and with communitarian periodontal index higher than 1(CPI > 1). Samples of saliva and gingival crevice fluid were extracted with calibrated micro-capillaries and deposited on Si reflectors. Known amounts of Ga were added to the samples in order to act as internal standard for quantification by the total reflection x-ray fluorescence technique. Experimental concentrations of several elements (P, S, Cl, K, Ca, Cr, Fe, NI, Cu, and Zn) were determined. The concentration of some elements in saliva showed different behavior as compared to gingival crevice fluid. Some critical elements of bone composition, such as Ca and Zn, present very distinguishable behavior. Improvements in the statistics are required for a better assessment of a routine method and to establish some correlation with periodontal disease. TXRF seems to be a promising method to evaluate the evolution of osteoporosis.

  20. Vapor phase treatment–total reflection X-ray fluorescence for trace elemental analysis of silicon wafer surface

    International Nuclear Information System (INIS)

    Takahara, Hikari; Mori, Yoshihiro; Shibata, Harumi; Shimazaki, Ayako; Shabani, Mohammad B.; Yamagami, Motoyuki; Yabumoto, Norikuni; Nishihagi, Kazuo; Gohshi, Yohichi

    2013-01-01

    Vapor phase treatment (VPT) was under investigation by the International Organization for Standardization/Technical Committee 201/Working Group 2 (ISO/TC201/WG2) to improve the detection limit of total reflection X-ray fluorescence spectroscopy (TXRF) for trace metal analysis of silicon wafers. Round robin test results have confirmed that TXRF intensity increased by VPT for intentional contamination with 5 × 10 9 and 5 × 10 10 atoms/cm 2 Fe and Ni. The magnification of intensity enhancement varied greatly (1.2–4.7 in VPT factor) among the participating laboratories, though reproducible results could be obtained for average of mapping measurement. SEM observation results showed that various features, sizes, and surface densities of particles formed on the wafer after VPT. The particle morphology seems to have some impact on the VPT efficiency. High resolution SEM observation revealed that a certain number of dots with SiO 2 , silicate and/or carbon gathered to form a particle and heavy metals, Ni and Fe in this study were segregated on it. The amount and shape of the residue should be important to control VPT factor. - Highlights: • This paper presents a summary of study results of VPT–TXRF using ISO/TC201/WG2. • Our goal is to analyze the trace metallic contamination on silicon wafer with concentrations below 1 × 10 10 atoms/cm 2 . • The efficiency and mechanism of VPT are discussed under several round robin tests and systematic studies

  1. Total reflection X-ray fluorescence analysis of oral fluids of women affected by osteoporosis and osteopenia

    International Nuclear Information System (INIS)

    Sanchez, Hector Jorge; Valentinuzzi, Maria Cecilia; Grenon, Miram; Abraham, Jose

    2008-01-01

    Osteoporosis is a disease characterized by low bone mass and microarchitectural deterioration of bone tissue, leading to bone fragility and an increased susceptibility to fractures; the early stage of decreased bone density is called osteopenia. More than 200 million people are affected and about 50% of post-menopausic women are expected to develop the disease. Osteoporosis, osteopenia and periodontal disease have in common several risk factors, being hyperthyroidism and smoking habits the most important ones. There is scarce information in the literature about the association between periodontal disease and osteoporosis and/or osteopenia. Some works suggest that osteoporotic women are susceptible to a higher loss of periodontal insertion, alveolar bones, and teeth. Thirty adult post-menopausic women were studied; some of them were healthy (control group) and the rest of them were undergoing some stage of osteoporosis or osteopenia. All the subjects were healthy, non-smokers, not having dental implants, and with communitarian periodontal index higher than 1(CPI > 1). Samples of saliva and gingival crevice fluid were extracted with calibrated micro-capillaries and deposited on Si reflectors. Known amounts of Ga were added to the samples in order to act as internal standard for quantification by the total reflection x-ray fluorescence technique. Experimental concentrations of several elements (P, S, Cl, K, Ca, Cr, Fe, NI, Cu, and Zn) were determined. The concentration of some elements in saliva showed different behavior as compared to gingival crevice fluid. Some critical elements of bone composition, such as Ca and Zn, present very distinguishable behavior. Improvements in the statistics are required for a better assessment of a routine method and to establish some correlation with periodontal disease. TXRF seems to be a promising method to evaluate the evolution of osteoporosis

  2. Total reflection X-ray fluorescence analysis of oral fluids of women affected by osteoporosis and osteopenia

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Hector Jorge [Facultad de Matematica Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina)], E-mail: jsan@famaf.unc.edu.ar; Valentinuzzi, Maria Cecilia [Facultad de Matematica Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina); Grenon, Miram [Facultad de Odontologia, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina); Abraham, Jose [Facultad de Matematica Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina)

    2008-12-15

    Osteoporosis is a disease characterized by low bone mass and microarchitectural deterioration of bone tissue, leading to bone fragility and an increased susceptibility to fractures; the early stage of decreased bone density is called osteopenia. More than 200 million people are affected and about 50% of post-menopausic women are expected to develop the disease. Osteoporosis, osteopenia and periodontal disease have in common several risk factors, being hyperthyroidism and smoking habits the most important ones. There is scarce information in the literature about the association between periodontal disease and osteoporosis and/or osteopenia. Some works suggest that osteoporotic women are susceptible to a higher loss of periodontal insertion, alveolar bones, and teeth. Thirty adult post-menopausic women were studied; some of them were healthy (control group) and the rest of them were undergoing some stage of osteoporosis or osteopenia. All the subjects were healthy, non-smokers, not having dental implants, and with communitarian periodontal index higher than 1(CPI > 1). Samples of saliva and gingival crevice fluid were extracted with calibrated micro-capillaries and deposited on Si reflectors. Known amounts of Ga were added to the samples in order to act as internal standard for quantification by the total reflection x-ray fluorescence technique. Experimental concentrations of several elements (P, S, Cl, K, Ca, Cr, Fe, NI, Cu, and Zn) were determined. The concentration of some elements in saliva showed different behavior as compared to gingival crevice fluid. Some critical elements of bone composition, such as Ca and Zn, present very distinguishable behavior. Improvements in the statistics are required for a better assessment of a routine method and to establish some correlation with periodontal disease. TXRF seems to be a promising method to evaluate the evolution of osteoporosis.

  3. 1. Latin American Workshop on Total Reflection X-Ray Fluorescence (TXRF) and its Applications: TARABANA 99. Programme and Abstracts

    International Nuclear Information System (INIS)

    Vegas C, Fredy; Greaves N, Eduardo; Marco P, Lue-Meru

    1999-01-01

    It concerns about the advances in Total Reflection X-Ray Fluorescence (TXRF) instrumentation; structure, characteristic and potential of TXRF equipment used for chemical multielemental survey; TXRF: an approach to nano analysis; microanalytical investigation of environmental samples by TXRF spectrometry; TXRF of low Z elements; assessment of serum selenium levels in 2 month old sucking calves using TXRF: A powerful method to investigate the elemental composition of spheroids; environmental applications of TXRF; use of modifiers for the elimination in situ of chlorides in the analysis of TXRF; experimental methodology and analysis spectra for the determination of mercury by means of TXRF using amalgamation with gold; multielemental analysis of human amniotic fluid by use of Total Reflection X-Ray Fluorescence and rutherford forward scattering; determination of metal in samples of handmade penca; determination of oligo elements, platinum and relationship Zn/Cu in samples of blood serum and urine in oncological pediatric patient [es

  4. Optimizing total reflection X-ray fluorescence for direct trace element quantification in proteins I: Influence of sample homogeneity and reflector type

    Science.gov (United States)

    Wellenreuther, G.; Fittschen, U. E. A.; Achard, M. E. S.; Faust, A.; Kreplin, X.; Meyer-Klaucke, W.

    2008-12-01

    Total reflection X-ray fluorescence (TXRF) is a very promising method for the direct, quick and reliable multi-elemental quantification of trace elements in protein samples. With the introduction of an internal standard consisting of two reference elements, scandium and gallium, a wide range of proteins can be analyzed, regardless of their salt content, buffer composition, additives and amino acid composition. This strategy also enables quantification of matrix effects. Two potential issues associated with drying have been considered in this study: (1) Formation of heterogeneous residues of varying thickness and/or density; and (2) separation of the internal standard and protein during drying (which has to be prevented to allow accurate quantification). These issues were investigated by microbeam X-ray fluorescence (μXRF) with special emphasis on (I) the influence of sample support and (II) the protein / buffer system used. In the first part, a model protein was studied on well established sample supports used in TXRF, PIXE and XRF (Mylar, siliconized quartz, Plexiglas and silicon). In the second part we imaged proteins of different molecular weight, oligomerization state, bound metals and solubility. A partial separation of protein and internal standard was only observed with untreated silicon, suggesting it may not be an adequate support material. Siliconized quartz proved to be the least prone to heterogeneous drying of the sample and yielded the most reliable results.

  5. Optimizing total reflection X-ray fluorescence for direct trace element quantification in proteins I: Influence of sample homogeneity and reflector type

    Energy Technology Data Exchange (ETDEWEB)

    Wellenreuther, G. [European Molecular Biology Laboratory, Notkestr. 85, 22603 Hamburg (Germany); Fittschen, U.E.A. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Achard, M.E.S.; Faust, A.; Kreplin, X. [European Molecular Biology Laboratory, Notkestr. 85, 22603 Hamburg (Germany); Meyer-Klaucke, W. [European Molecular Biology Laboratory, Notkestr. 85, 22603 Hamburg (Germany)], E-mail: Wolfram@embl-hamburg.de

    2008-12-15

    Total reflection X-ray fluorescence (TXRF) is a very promising method for the direct, quick and reliable multi-elemental quantification of trace elements in protein samples. With the introduction of an internal standard consisting of two reference elements, scandium and gallium, a wide range of proteins can be analyzed, regardless of their salt content, buffer composition, additives and amino acid composition. This strategy also enables quantification of matrix effects. Two potential issues associated with drying have been considered in this study: (1) Formation of heterogeneous residues of varying thickness and/or density; and (2) separation of the internal standard and protein during drying (which has to be prevented to allow accurate quantification). These issues were investigated by microbeam X-ray fluorescence ({mu}XRF) with special emphasis on (I) the influence of sample support and (II) the protein / buffer system used. In the first part, a model protein was studied on well established sample supports used in TXRF, PIXE and XRF (Mylar, siliconized quartz, Plexiglas and silicon). In the second part we imaged proteins of different molecular weight, oligomerization state, bound metals and solubility. A partial separation of protein and internal standard was only observed with untreated silicon, suggesting it may not be an adequate support material. Siliconized quartz proved to be the least prone to heterogeneous drying of the sample and yielded the most reliable results.

  6. Determination of solid surface composition by the X-ray fluorescence method under total external reflection with angular scanning

    International Nuclear Information System (INIS)

    Krasnolutskij, V.P.

    2000-01-01

    Possibilities of determination of composition of surface layers by X-ray fluorescence analysis under total reflection of incident radiation with angular scanning of a target are investigated. For the case of the GaAs target it is shown that the sensibility of this method is sufficient for a control of element composition in layer of thickness 1 nm. A simple method for solution of inverse task of analysis of a two component medium is considered [ru

  7. Pigment particles analysis with a total reflection X-ray fluorescence spectrometer: study of influence of instrumental parameters

    Energy Technology Data Exchange (ETDEWEB)

    Coccato, Alessia; Vandenabeele, Peter [Ghent University, Department of Archaeology, Ghent (Belgium); Vekemans, Bart; Vincze, Laszlo; Moens, Luc [Ghent University, Department of Analytical Chemistry, Ghent (Belgium)

    2016-12-15

    Total reflection X-ray fluorescence (TXRF) analysis is an excellent tool to determine major, minor and trace elements in minuscule amounts of samples, making this technique very suitable for pigment analysis. Collecting minuscule amounts of pigment material from precious works of art by means of a cotton swab is a well-accepted sampling method, but poses specific challenges when TXRF is to be used for the characterization of the unknown material. (orig.)

  8. Determination of total As in onion plants growing in contaminated substrates by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Lue-Meru Marco Parra

    2011-01-01

    The onion (Allium cepa L.) is one of the most important cultivars in the world and its production level occupies the second place in Venezuela. It becomes important to develop analytical procedures for arsenic determination and to study the effect of this element on the cultures, as well the absorption, transport and translocation processes. A TXRF method for As determination in onions was developed. Two treatments were applied to the onion plants, As contaminated and control. The contaminant was added to the plants to an amount of 100 μg, in a single time 3 weeks after the transplant of plantlets. The green leaves bulbs, and roots together with the stems were separated 45 days after transplant and analyzed by TXRF and HG-AAS for total Arsenic determination. A good agreement was found between these two techniques, demonstrating the accuracy of the TXRF procedure. It was found that the highest concentration corresponded to the root and stems (37 ± 31 μg g -1 ), followed by the bulbs (11 ± 7 μg g -1 ), being the smallest level found in the green leaves (4 ± 3 μg g -1 ). At low As contamination levels of 0.25 μg g -1 , a risk for translocation of the toxic element to the edible parts of the onion plants exists. At this level the normal development of the plant is not affected, being the only exception the root length, which is significantly higher in the contaminated treatment. (author)

  9. A plastic total internal reflection-based photoluminescence device for enzymatic biosensors

    Science.gov (United States)

    Thakkar, Ishan G.

    Growing concerns for quality of water, food and beverages in developing and developed countries drive sizeable markets for mass-producible, low cost devices that can measure the concentration of contaminant chemicals in water, food, and beverages rapidly and accurately. Several fiber-optic enzymatic biosensors have been reported for these applications, but they exhibit very strong presence of scattered excitation light in the signal for sensing, requiring expensive thin-film filters, and their non-planar structure makes them challenging to mass-produce. Several other planar optical waveguide-based biosensors prove to be relatively costly and more fragile due to constituent materials and the techniques involved in their fabrication. So, a plastic total internal reflection (TIR)-based low cost, low scatter, field-portable device for enzymatic biosensors is fabricated and demonstrated. The design concept of the TIR-based photoluminescent enzymatic biosensor device is explained. An analysis of economical materials with appropriate optical and chemical properties is presented. PMMA and PDMS are found to be appropriate due to their high chemical resistance, low cost, high optical transmittance and low auto-fluorescence. The techniques and procedures used for device fabrication are discussed. The device incorporated a PMMA-based optical waveguide core and PDMS-based fluid cell with simple multi-mode fiber-optics using cost-effective fabrication techniques like molding and surface modification. Several techniques of robustly depositing photoluminescent dyes on PMMA core surface are discussed. A pH-sensitive fluorescent dye, fluoresceinamine, and an O2-sensitive phosphorescent dye, Ru(dpp) both are successfully deposited using Si-adhesive gel-based as well as HydroThane-based deposition methods. Two different types of pH-sensors using two different techniques of depositing fluoresceinamine are demonstrated. Also, the effect of concentration of fluoresceinamine-dye molecules

  10. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    Energy Technology Data Exchange (ETDEWEB)

    Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria)]. E-mail: streli@ati.ac.at; Pepponi, G. [ITC-irst, Povo (Italy); Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Jokubonis, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, D-22603 Hamburg (Germany); Zaray, G. [Institute of Inorganic and Applied Chemistry, 3 EOTVOS Univ, Budapest (Hungary); Broekaert, J. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Fittschen, U. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Peschel, B. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)

    2006-11-15

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm{sup 2} active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm{sup 2} silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al{sub 2}O{sub 3}. No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are

  11. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    International Nuclear Information System (INIS)

    Streli, C.; Pepponi, G.; Wobrauschek, P.; Jokubonis, C.; Falkenberg, G.; Zaray, G.; Broekaert, J.; Fittschen, U.; Peschel, B.

    2006-01-01

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm 2 active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm 2 silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al 2 O 3 . No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are reported. Detection

  12. Fluorescent BAPAD Dendrimeric Antigens Are Efficiently Internalized by Human Dendritic Cells

    Directory of Open Access Journals (Sweden)

    Pablo Mesa-Antunez

    2016-03-01

    Full Text Available A new fluorescent dendrimeric antigen (DeAn based on a dendron with amoxicilloyl terminal groups was synthesized. The synthesis was carried out using a novel class of all-aliphatic polyamide dendrimer (BisAminoalkylPolyAmide Dendrimers, or BAPAD involving the direct condensation of 3,3′-diazidopivalic acid as a building block. Iterative azide reduction/amide formation increases the dendrimer generation. The BAPAD dendrimer was designed with a cystamine core. Reduction of the disulfide bond allows the incorporation of BAPAD dendrons into a 1,8-naphthalimide functionalized with a maleimide group. The fluorescence properties of DeAn were studied in PBS and compared with the properties of an equivalent dendron possessing amino-terminal groups. Both molecules shown high fluorescence quantum yields in PBS and could readily be visualized by fluorescence microscopy. DeAn was used as a synthetic antigen in a biomedical assay that tests their potential as an amoxicillin carrier in drug internalization by dendritic cells (DC from tolerant and allergic patients. Cytometry data suggest that the dendrons are non-toxic and easily internalized by DCs, while confocal microscopy images indicate that the compounds are preferentially accumulated in the cytoplasm. These results indicate that BAPAD dendrons are good candidates for synthetic scaffolds for biomedical applications.

  13. Refractive Index Imaging of Cells with Variable-Angle Near-Total Internal Reflection (TIR) Microscopy.

    Science.gov (United States)

    Bohannon, Kevin P; Holz, Ronald W; Axelrod, Daniel

    2017-10-01

    The refractive index in the interior of single cells affects the evanescent field depth in quantitative studies using total internal reflection (TIR) fluorescence, but often that index is not well known. We here present method to measure and spatially map the absolute index of refraction in a microscopic sample, by imaging a collimated light beam reflected from the substrate/buffer/cell interference at variable angles of incidence. Above the TIR critical angle (which is a strong function of refractive index), the reflection is 100%, but in the immediate sub-critical angle zone, the reflection intensity is a very strong ascending function of incidence angle. By analyzing the angular position of that edge at each location in the field of view, the local refractive index can be estimated. In addition, by analyzing the steepness of the edge, the distance-to-substrate can be determined. We apply the technique to liquid calibration samples, silica beads, cultured Chinese hamster ovary cells, and primary culture chromaffin cells. The optical technique suffers from decremented lateral resolution, scattering, and interference artifacts. However, it still provides reasonable results for both refractive index (~1.38) and for distance-to-substrate (~150 nm) for the cells, as well as a lateral resolution to about 1 µm.

  14. Fluorescence microscopy.

    Science.gov (United States)

    Sanderson, Michael J; Smith, Ian; Parker, Ian; Bootman, Martin D

    2014-10-01

    Fluorescence microscopy is a major tool with which to monitor cell physiology. Although the concepts of fluorescence and its optical separation using filters remain similar, microscope design varies with the aim of increasing image contrast and spatial resolution. The basics of wide-field microscopy are outlined to emphasize the selection, advantages, and correct use of laser scanning confocal microscopy, two-photon microscopy, scanning disk confocal microscopy, total internal reflection, and super-resolution microscopy. In addition, the principles of how these microscopes form images are reviewed to appreciate their capabilities, limitations, and constraints for operation. © 2014 Cold Spring Harbor Laboratory Press.

  15. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zarazua, G. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico)]. E-mail: gzo@nuclear.inin.mx; Avila-Perez, P. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Tejeda, S. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Barcelo-Quintal, I. [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Mexico, D.F. (Mexico); Martinez, T. [Universidad Nacional Autonoma de Mexico, Facultad de Quimica, Mexico, D.F. (Mexico)

    2006-11-15

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 {mu}g/L) > Mn (300 {mu}g/L) > Cu (66 {mu}g/L) > Cr (21 {mu}g/L) > Pb (15 {mu}g/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits.

  16. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Zarazua, G.; Ávila-Pérez, P.; Tejeda, S.; Barcelo-Quintal, I.; Martínez, T.

    2006-11-01

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 μg/L) > Mn (300 μg/L) > Cu (66 μg/L) > Cr (21 μg/L) > Pb (15 μg/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits.

  17. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Zarazua, G.; Avila-Perez, P.; Tejeda, S.; Barcelo-Quintal, I.; Martinez, T.

    2006-01-01

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 μg/L) > Mn (300 μg/L) > Cu (66 μg/L) > Cr (21 μg/L) > Pb (15 μg/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits

  18. Development of a total reflection X-ray fluorescence spectrometer for ...

    Indian Academy of Sciences (India)

    Unknown

    design and use of a peltier cooled solid state detector for energy dispersive detection. Alignment and ... X-ray beam at a glancing angle less than the critical angle at which total ... materials is < 1 so that external total reflection takes place at an ...

  19. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Amberger, Martin A.; Hoeltig, Michael; Broekaert, Jose A.C.

    2010-01-01

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL -1 . As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL -1 of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 μg g -1 for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al 2 O 3 , powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective samples over a

  20. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Amberger, Martin A.; Hoeltig, Michael [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany); Broekaert, Jose A.C., E-mail: jose.broekaert@chemie.uni-hamburg.d [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany)

    2010-02-15

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL{sup -1}. As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL{sup -1} of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 mug g{sup -1} for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al{sub 2}O{sub 3}, powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective

  1. Background estimation in short-wave region during determination of total sample composition by x-ray fluorescence method

    International Nuclear Information System (INIS)

    Simakov, V.A.; Kordyukov, S.V.; Petrov, E.N.

    1988-01-01

    Method of background estimation in short-wave spectral region during determination of total sample composition by X-ray fluorescence method is described. 13 types of different rocks with considerable variations of base composition and Zr, Nb, Th, U content below 7x10 -3 % are investigated. The suggested method of background accounting provides for a less statistical error of the background estimation than direct isolated measurement and reliability of its determination in a short-wave region independent on the sample base. Possibilities of suggested method for artificial mixtures conforming by the content of main component to technological concemtrates - niobium, zirconium, tantalum are estimated

  2. Analytical characterization of artists' pigments used in old and modern paintings by total-reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bohlen, A. von; Moens, L.; Devos, W.

    1993-01-01

    The analytical characterization of artists' pigments is a most helpful tool for art history, conservation and restoration of paintings. A very gentle method of ultra-microsampling was developed that is especially applicable to paintings under restoration. It provides a sample mass of about 1 μg and is virtually non-destructive. This minute amount is sufficient for total-reflection X-ray fluorescence (TXRF) to determine most of those elements building inorganic pigments. The convenient and fast method was applied to oil paintings. Various pigments were identified and their mixing proportion was determined even quantitatively. (author)

  3. Trace elemental analysis of leaching solutions of hijiki seaweeds by a portable total reflection X-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Liu, Ying; Imashuku, Susumu; Kawai, Jun

    2014-01-01

    A portable total reflection X-ray fluorescence spectrometer (TXRF) was used to analyze leaching solutions of hijiki seaweeds. S, Cl, K, Ca, Ti, Fe, Ni, As and Br were detected in the solutions. Arsenic quantification results were compared to those from ICP-AES. The TXRF quantification results of arsenic were not significantly different from those of ICP-AES, as two-way analysis of variance (ANOVA) method was applied to the significance test. This kind of small and high sensitive TXRF spectrometer can be used in food quality and environmental pollution investigation. (author)

  4. Elemental concentration in normal skin and fibroepithelial polip lesions by synchrotron radiation total reflection X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Soares, Julio C.A.C.R.; Canellas, Catarine G.L.; Lopes, Ricardo T.; Anjos, Marcelino J.

    2011-01-01

    In this work, the concentrations of trace elements were measured in acrochordon, a skin lesion also known as skin tag or fibroepithelial polyp, as well as in normal skin from the same patient. The samples were analysed by Synchrotron Radiation Total Reflection X- ray Fluorescence (SRTXRF) in the Synchrotron Light National Laboratory (LNLS) in Campinas/Sao Paulo-Brazil. The collection of lesion and healthy skin samples, including papillary dermis and epidermis, has involved 17 patients. It was evaluated the presence of P, S, Cl, K, Ca, Cr, Mn, Fe, Cu, Zn, Br and Rb in the paired samples, which were compared, and significant differences were found in some of them. (author)

  5. A method for thickness determination of thin films of amalgamable metals by total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Bennun, L.; Greaves, E.D.; Barros, H.; Diaz-Valdes, J.

    2009-01-01

    A method for thickness determination of thin amalgamable metallic films by total-reflection X-ray fluorescence (TXRF) is presented. The peak's intensity in TXRF spectra are directly related to the surface density of the sample, i.e. to its thickness in a homogeneous film. Performing a traditional TXRF analysis on a thin film of an amalgamated metal, and determining the relative peak intensity of a specific metal line, the layer thickness can be precisely obtained. In the case of gold thickness determination, mercury and gold peaks overlap, hence we have developed a general data processing scheme to achieve the most precise results.

  6. Fluorescence characteristics of the fuel tracers triethylamine and trimethylamine for the investigation of fuel distribution in internal combustion engines.

    Science.gov (United States)

    Lind, Susanne; Aßmann, Simon; Zigan, Lars; Will, Stefan

    2016-03-01

    Laser-induced fluorescence based on fuel tracers like amines is a suitable measurement technique for mixing studies in internal combustion (IC) engines. Triethylamine has often been used in gasoline IC engines; however, no detailed fluorescence characterization for excitation at 263 or 266 nm is available. Trimethylamine (TMA) exhibits high potential as a gaseous fuel tracer but little information about TMA fluorescence is currently available. A picosecond laser source combined with a streak camera equipped with a spectrograph was used to determine the spectral fluorescence emission and fluorescence decay time of both tracers. The tracers were investigated at various temperatures and pressures in a calibration cell with nitrogen as bath gas. The results provide an in-depth understanding of the fluorescence characteristics of both tracers and allow assessment of their application to the investigation of fuel distribution in IC engines.

  7. Simultaneous determination of total arsenic and total selenium in Chinese medicinal herbs by hydride generation atomic fluorescence spectrometry in tartaric acid medium

    International Nuclear Information System (INIS)

    Liu Zhanfeng; Sun Hanwen; Shen Shigang; Li Liqing; Shi Hongmei

    2005-01-01

    By HG-AFS, a new method was proposed for simultaneous determination of total arsenic and total selenium existed in the Chinese medicinal herbs in tartaric acid medium. The effects of analytical conditions and coexisting ions on the fluorescence signal intensity of analytes were investigated. The proposed method was provided with linear response ranges above 22 μg l -1 for As and 44 μg l -1 for Se, and the detection limits of 0.13 and 0.12 μg l -1 were obtained for As and Se respectively. The recoveries of 93.8-96.1% for As and 95.3-99.1% for Se, and the precision of 1.2-3.8% and 2.4-5.3% (R.S.D., n = 8) respectively, were obtained via simultaneous determined four samples of Chinese medicinal herbs and three certified botanic reference materials successfully. The proposed method has the advantages of simple operation, high sensitivity and high efficiency

  8. Determination of total and inorganic mercury in fish samples with on-line oxidation coupled to atomic fluorescence spectrometry

    International Nuclear Information System (INIS)

    Shao Lijun; Gan Wuer; Su Qingde

    2006-01-01

    An atomic fluorescence spectrometry system for determination of total and inorganic mercury with electromagnetic induction-assisted heating on-line oxidation has been developed. Potassium peroxodisulphate was used as the oxidizing agent to decompose organomercury compounds. Depending on the temperature selected, inorganic or total mercury could be determined with the same manifold. Special accent was put on the study of the parameters influencing the on-line digestion efficiency. The tolerance to the interference of coexisting ions was carefully examined in this system. Under optimal conditions, the detection limits (3σ) were evaluated to be 2.9 ng l -1 for inorganic mercury and 2.6 ng l -1 for total mercury, respectively. The relative standard deviations for 10 replicate determinations of 1.0 μg l -1 Hg were 2.4 and 3.2% for inorganic mercury and total mercury, respectively. The proposed method was successfully applied to the determination of total and inorganic mercury in fish samples

  9. Energy dispersive X-ray fluorescence analysis with multiple total reflection

    International Nuclear Information System (INIS)

    Freitag, K.

    1985-01-01

    The development of a total reflection XRF analyzer and the performance data of this instrument are described. The drastic reduction of the scattered radiation is the outstanding property of the method. Detection limits of elements and matrix effects are discussed. The competition with other methods of analysis has proven its advantages in a wide range. In addition to its multi-element features down to the picogram level, particularly its universal calibration function has turned out to be a great help in the analytical practice. (orig./RB)

  10. Analysis of low Z elements in various environmental samples with total reflection X-ray fluorescence (TXRF) spectrometry

    International Nuclear Information System (INIS)

    Hoefler, H.; Streli, C.; Wobrauschek, P.; Ovari, M.; Zaray, Gy.

    2006-01-01

    Recently there is a growing interest in low Z elements such as carbon, oxygen up to sulphur and phosphorus in biological specimen. Total reflection X-ray fluorescence (TXRF) spectrometry is a suitable technique demanding only very small amounts of sample. On the other side, the detection of low Z elements is a critical point of this analytical technique. Besides other effects, self absorption may occur in the samples, because of the low energy of the fluorescence radiation. The calibration curves might be not linear any longer. To investigate this issue water samples and samples from human cerebrospinal fluid were used to examine absorption effects. The linearity of calibration curves in dependence of sample mass was investigated to verify the validity of the thin film approximation. The special requirements to the experimental setup for low Z energy dispersive fluorescence analysis were met by using the Atominstitute's TXRF vacuum chamber. This spectrometer is equipped with a Cr-anode X-ray tube, a multilayer monochromator and a SiLi detector with 30 mm 2 active area and with an ultrathin entrance window. Other object on this study are biofilms, living on all subaqueous surfaces, consisting of bacteria, algae and fungi embedded in their extracellular polymeric substances (EPS). Many trace elements from the water are bound in the biofilm. Thus, the biofilm is a useful indicator for polluting elements. For biomonitoring purposes not only the polluting elements but also the formation and growth rate of the biofilm are important. Biofilms were directly grown on TXRF reflectors. Their major elements and C-masses correlated to the cultivation time were investigated. These measured masses were related to the area seen by the detector, which was experimentally determined. Homogeneity of the biofilms was checked by measuring various sample positions on the reflectors

  11. Analysis of low Z elements in various environmental samples with total reflection X-ray fluorescence (TXRF) spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hoefler, H. [Atominstitut of the Austrian Universities, TU-Wien, A-1020 Vienna (Austria); Streli, C. [Atominstitut of the Austrian Universities, TU-Wien, A-1020 Vienna (Austria)]. E-mail: streli@ati.ac.at; Wobrauschek, P. [Atominstitut of the Austrian Universities, TU-Wien, A-1020 Vienna (Austria); Ovari, M. [Eoetvoes University, Institute of Chemistry, H-1117, Budapest, Pazmany P. stny 1/a. (Hungary); Zaray, Gy. [Eoetvoes University, Institute of Chemistry, H-1117, Budapest, Pazmany P. stny 1/a. (Hungary)

    2006-11-15

    Recently there is a growing interest in low Z elements such as carbon, oxygen up to sulphur and phosphorus in biological specimen. Total reflection X-ray fluorescence (TXRF) spectrometry is a suitable technique demanding only very small amounts of sample. On the other side, the detection of low Z elements is a critical point of this analytical technique. Besides other effects, self absorption may occur in the samples, because of the low energy of the fluorescence radiation. The calibration curves might be not linear any longer. To investigate this issue water samples and samples from human cerebrospinal fluid were used to examine absorption effects. The linearity of calibration curves in dependence of sample mass was investigated to verify the validity of the thin film approximation. The special requirements to the experimental setup for low Z energy dispersive fluorescence analysis were met by using the Atominstitute's TXRF vacuum chamber. This spectrometer is equipped with a Cr-anode X-ray tube, a multilayer monochromator and a SiLi detector with 30 mm{sup 2} active area and with an ultrathin entrance window. Other object on this study are biofilms, living on all subaqueous surfaces, consisting of bacteria, algae and fungi embedded in their extracellular polymeric substances (EPS). Many trace elements from the water are bound in the biofilm. Thus, the biofilm is a useful indicator for polluting elements. For biomonitoring purposes not only the polluting elements but also the formation and growth rate of the biofilm are important. Biofilms were directly grown on TXRF reflectors. Their major elements and C-masses correlated to the cultivation time were investigated. These measured masses were related to the area seen by the detector, which was experimentally determined. Homogeneity of the biofilms was checked by measuring various sample positions on the reflectors.

  12. Small-displacement sensing system based on multiple total internal reflections in heterodyne interferometry.

    Science.gov (United States)

    Wang, Shinn-Fwu; Chiu, Ming-Hung; Chen, Wei-Wu; Kao, Fu-Hsi; Chang, Rong-Seng

    2009-05-01

    A small-displacement sensing system based on multiple total internal reflections in heterodyne interferometry is proposed. In this paper, a small displacement can be obtained only by measuring the variation in phase difference between s- and p-polarization states for the total internal reflection effect. In order to improve the sensitivity, we increase the number of total internal reflections by using a parallelogram prism. The theoretical resolution of the method is better than 0.417 nm. The method has some merits, e.g., high resolution, high sensitivity, and real-time measurement. Also, its feasibility is demonstrated.

  13. Multielement analysis of aerosol samples by X-ray fluorescence analysis with totally reflecting sample holders

    International Nuclear Information System (INIS)

    Ketelsen, P.; Knoechel, A.

    1984-01-01

    Aerosole samples on filter support were analyzed using the X-ray flourescence analytical method (Mo excitation) with totally reflecting sample carrier (TXFA). Wet decomposition of the sample material with HNO 3 in an enclosed system and subsequent sample preparation by evaporating an aliquot of the solution on the sample carrier yields detection limits up to 0.3 ng/cm 2 . The reproducibilities of the measurements of the elements K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb lie between 5 and 25%. Similar detection limits and reproducibilities are obtained, when low-temperature oxygen plasma is employed for the direct ashing of the homogenously covered filter on the sample carrier. For the systematic loss of elements both methods were investigated with radiotracers as well as with inactive techniques. A comparison of the results with those obtained by NAA, AAS and PIXE shows good agreement in most cases. For the bromine determination and the fast coverage of the main elements a possibility for measuring the filter membrane has been indicated, which neglects the ashing step. The corresponding detection limits are up to 3 ng/cm 2 . (orig.) [de

  14. Total Reflection X-ray Fluorescence Analysis (TXRF) using the high flux SAXS camera

    CERN Document Server

    Wobrauschek, P; Pepponi, G; Bergmann, A; Glatter, O

    2002-01-01

    Combining the high photon flux from a rotating anode X-ray tube with an X-ray optical component to focus and monochromatize the X-ray beam is the most promising instrumentation for best detection limits in the modern XRF laboratory. This is realized by using the design of a high flux SAXS camera in combination with a 4 kW high brilliant rotating Cu anode X-ray tube with a graded elliptically bent multilayer and including a new designed module for excitation in total reflection geometry within the beam path. The system can be evacuated thus reducing absorption and scattering of air and removing the argon peak in the spectra. Another novelty is the use of a Peltier cooled drift detector with an energy resolution of 148 eV at 5.9 keV and 5 mm sup 2 area. For Co detection limits of about 300 fg determined by a single element standard have been achieved. Testing a real sample NIST 1643d led to detection limits in the range of 300 ng/l for the medium Z.

  15. Determination of mercury in seawater by total reflection x-ray fluorescence spectrometry after an electrochemical preconcentration method

    International Nuclear Information System (INIS)

    Ritschel, A.; Chinea Cano, E.; Wobrauschek, P.; Kuntner, C.; Durakbasa, M.N.

    2000-01-01

    A new combined method of electrodeposition of trace elements on metallic plates with subsequent total-reflection x-ray fluorescence spectrometry (TXRF) is proposed for the determination of trace metals in natural waters. The elements of interest are electroplated on highly polished niobium discs which are used as sample carriers for the TXRF measurement. The electrochemical preconcentration is performed in a flow cell under a controlled working electrode potential. The preconcentration step involves only very little manipulation which minimizes the risk of contamination of the sample. The method was investigated by analyzing inorganic mercury in sea water. A detection limit of 7 ngl -1 could be achieved for mercury in a 40 ml sea water sample. (author)

  16. Fish samples as bioindicator of environmental quality: synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    International Nuclear Information System (INIS)

    Vives, Ana Elisa Sirito de; Moreira, Silvana; Brienza, Sandra Maria Boscolo; Zucchi, Orgheda Luiza Araujo Domingues; Nascimento Filho, Virgilio Franco do Centro de Energia Nuclear na Agricultura , Piracicaba, SP; Brazil)

    2005-01-01

    In this study fish were used as bioindicators of environmental contamination. The species were collected in Piracicaba River, Sao Paulo state, Brazil and the toxic elements concentrations were determined in muscle tissue and viscus (liver, intestine and stomach) by Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF). Were determined the elements Ti, Cr, Mn, Fe, Ni, Cu, Zn and Ba. The results were compared with values established by Brazilian Legislation for general food. The elements concentrations evidenced potential risk to human health and environmental quality alteration of the studied area. The measurements were realized at the 'Laboratorio Nacional de Luz Sincrotron' (LNLS) located in Campinas, Sao Paulo State, Brazil. (author)

  17. Fish samples as bioindicator of environmental quality: synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Brienza, Sandra Maria Boscolo [Universidade Metodista de Piracicaba (UNIMEP), SP (Brazil). Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: virgilio@cena.usp.br

    2005-07-01

    In this study fish were used as bioindicators of environmental contamination. The species were collected in Piracicaba River, Sao Paulo state, Brazil and the toxic elements concentrations were determined in muscle tissue and viscus (liver, intestine and stomach) by Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF). Were determined the elements Ti, Cr, Mn, Fe, Ni, Cu, Zn and Ba. The results were compared with values established by Brazilian Legislation for general food. The elements concentrations evidenced potential risk to human health and environmental quality alteration of the studied area. The measurements were realized at the 'Laboratorio Nacional de Luz Sincrotron' (LNLS) located in Campinas, Sao Paulo State, Brazil. (author)

  18. Analysis of nutrition-relevant trace elements in human blood and serum by means of total reflection X-ray fluorescence (TXRF) spectroscopy

    International Nuclear Information System (INIS)

    Stosnach, Hagen; Mages, Margarete

    2009-01-01

    In clinical service laboratories, one of the most common analytical tasks with regard to inorganic traces is the determination of the nutrition-relevant elements Fe, Cu, Zn, and Se. Because of the high numbers of samples and the commercial character of these analyses, a time-consuming sample preparation must be avoided. In this presentation, the results of total reflection X-ray fluorescence measurements with a low-power system and different sample preparation procedures are compared with those derived from analysis with common methods like Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The results of these investigations indicate that the optimal total reflection X-ray fluorescence analysis of the nutrition-relevant elements Fe, Cu, Zn, and Se can be performed by preparing whole blood and serum samples after dilution with ultrapure water and transferring 10 μl of internally standardized sample to an unsiliconized quartz glass sample carrier with subsequent drying in a laboratory oven. Suitable measurement time was found to be 600 s. The enhanced sample preparation by means of microwave or open digestion, in parts combined with cold plasma ashing, led to an improvement of detection limits by a factor of 2 for serum samples while for whole blood samples an improvement was only observed for samples prepared by means of microwave digestion. As the matrix elements P, S, Cl, and for whole blood Fe have a major influence on the detection limits, most probably a further enhancement of analytical quality requires the removal of the organic matrix. However, for the routine analysis of the nutrition-relevant elements, the dilution preparation was found to be sufficient.

  19. Determination of total iron in iron ore by x-ray fluorescence analysis using the Compton effect: comparison with others analytical techniques

    International Nuclear Information System (INIS)

    Castilho, M.V. de; Oliveira, R.C.

    1991-01-01

    Total iron in iron ores is determines by X-ray fluorescence analysis method using the compton effect. The Bragg angle is determined for compton no-coherent scattering related to K alpha of Rhodium. This measurement procedure can be used for best fitting of analytical results in X-ray fluorescence, when compared with others methods used for results corrections. (M.V.M.)

  20. Worldwide distribution of Total Reflection X-ray Fluorescence instrumentation and its different fields of application: A survey

    Energy Technology Data Exchange (ETDEWEB)

    Klockenkämper, Reinhold, E-mail: reinhold.klockenkaemper@isas.de; Bohlen, Alex von

    2014-09-01

    A survey was carried out with users and manufacturers of Total Reflection X-ray Fluorescence instrumentation in order to demonstrate the worldwide distribution of TXRF equipment and the different fields of applications. In general, TXRF users come from universities and scientific institutes, from working places at synchrotron beam-lines, or laboratories in semiconductor fabs. TXRF instrumentation is distributed in more than 50 countries on six continents and is applied at about 200 institutes and laboratories. The number of running desktop instruments amounts to nearly 300 units. About 60 beamlines run working places dedicated to TXRF. About 300 floor-mounted instruments are estimated to be used in about 150 fabs of the semiconductor industry. In total, 13 different fields of applications could be registered statistically from three different aspects. - Highlights: • According to the survey world maps show the distribution of TXRF equipment. • Nearly 700 individual units are running actually in 57 countries of 6 continents. • Users work at 200 universities, 60 synchrotron-beamlines, and 150 semiconductor fabs. • 13 fields of applications (e.g. environmental, chemical) are evaluated statistically. • Manufacturers, conference members and authors lead to 3 different pie-charts.

  1. Determination of total and unbound warfarin and warfarin alcohols in human plasma by high performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Lomonaco, Tommaso; Ghimenti, Silvia; Piga, Isabella; Onor, Massimo; Melai, Bernardo; Fuoco, Roger; Di Francesco, Fabio

    2013-11-01

    Two analytical procedures are presented for the determination of the total content and unbound fraction of both warfarin and warfarin alcohols in human plasma. Chromatographic separation was carried out in isocratic conditions at 25°C on a C-18 reversed-phase column with a mobile phase consisting of a 70% buffer phosphate 25mM at pH=7, 25% methanol and 5% acetonitrile at a flow rate of 1.2mL/min. Fluorescence detection was performed at 390nm (excitation wavelength 310nm). Neither method showed any detectable interference or matrix effect. Inter-day recovery of the total warfarin and warfarin alcohols at a concentration level of 1000ng/mL was 89±3% and 73±3%, respectively, whereas for their unbound fraction (at a concentration level of 10ng/mL) was 66±8% and 90±7%, respectively. The intra- and inter-day precision (assessed as relative standard deviation) was alcohols, respectively. The methods were successfully applied to a pooled plasma sample obtained from 69 patients undergoing warfarin therapy. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. An Ultra-High Fluorescence Enhancement and High Throughput Assay for Revealing Expression and Internalization of Chemokine Receptor CXCR4.

    Science.gov (United States)

    He, Hua; Wang, Xiaojuan; Cheng, Tiantian; Xia, Yongqing; Lao, Jun; Ge, Baosheng; Ren, Hao; Khan, Naseer Ullah; Huang, Fang

    2016-04-18

    Revealing chemokine receptor CXCR4 expression, distribution, and internalization levels in different cancers helps to evaluate cancer progression or prognosis and to set personalized treatment strategy. We here describe a sensitive and high-throughput immunoassay for determining CXCR4 expression and distribution in cancer cells. The assay is accessible to a wide range of users in an ordinary lab only by dip-coating poly(styrene-co-N-isopropylacrylamide) spheres on the glass substrate. The self- assembled spheres form three-dimensional photonic colloidal crystals which enhance the fluorescence of CF647 and Alexa Fluor 647 by a factor of up to 1000. CXCR4 in cells is detected by using the sandwich immunoassay, where the primary antibody recognizes CXCR4 and the secondary antibody is labeled with CF647. With the newly established assay, we quantified the total expression of CXCR4, its distribution on the cell membrane and cytoplasm, and revealed their internalization level upon SDF-1α activation in various cancer cells, even for those with extremely low expression level. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Mass fragmentographic analysis of total cholesterol in serum using a heptadeuterated internal standard

    International Nuclear Information System (INIS)

    Wolthers, B.G.; Hindriks, F.R.; Muskiet, F.A.J.; Groen, A.

    1980-01-01

    A mass fragmentographic method for the determination of total cholesterol in serum using heptadeuterated [25,26,26,26,27,27,27- 2 H] cholesterol as internal standard is presented. The results obtained are compared with a colorimetric and gas chromatographic method which were previously proposed as reference methods. Criteria for the development of absolute measurement by means of mass fragmentography and stable isotopically labelled internal standards are given. The conclusion is drawn that, at present, mass fragmentographic methods for the determination of total cholesterol in serum do not fulfil the criteria required for absolute methods. (Auth.)

  4. Total reflection x-ray fluorescence spectroscopy as a tool for evaluation of iron concentration in ferrofluids and yeast samples

    Energy Technology Data Exchange (ETDEWEB)

    Kulesh, N.A., E-mail: nikita.kulesh@urfu.ru [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Novoselova, I.P. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Immanuel Kant Baltic Federal University, 236041 Kaliningrad (Russian Federation); Safronov, A.P. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Institute of Electrophysics UD RAS, Amundsen 106, 620016 Ekaterinburg (Russian Federation); Beketov, I.V.; Samatov, O.M. [Institute of Electrophysics UD RAS, Amundsen 106, 620016 Ekaterinburg (Russian Federation); Kurlyandskaya, G.V. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); University of the Basque Country UPV-EHU, 48940 Leioa (Spain); Morozova, M. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Denisova, T.P. [Irkutsk State University, Karl Marks 1, 664003 Irkutsk (Russian Federation)

    2016-10-01

    In this study, total reflection x-ray fluorescent (TXRF) spectrometry was applied for the evaluation of iron concentration in ferrofluids and biological samples containing iron oxide magnetic nanoparticles obtained by the laser target evaporation technique. Suspensions of maghemite nanoparticles of different concentrations were used to estimate the limitation of the method for the evaluation of nanoparticle concentration in the range of 1–5000 ppm in absence of organic matrix. Samples of single-cell yeasts grown in the nutrient media containing maghemite nanoparticles were used to study the nanoparticle absorption mechanism. The obtained results were analyzed in terms of applicability of TXRF for quantitative analysis in a wide range of iron oxide nanoparticle concentrations for biological samples and ferrofluids with a simple established protocol of specimen preparation. - Highlights: • Ferrofluids and yeasts samples were analysed by TXRF spectroscopy. • Simple protocol for iron quantification by means of TXRF was proposed. • Results were combined with magnetic, structural, and morphological characterization. • Preliminary conclusion on nanoparticles uptake mechanism was made.

  5. Inorganic pigment study of the San Pedro Gonzalez Telmo Sibyls using total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Cristina, E-mail: vazquez@cnea.gov.a [Universidad de Buenos Aires, Facultad de Ingenieria, Paseo Colon 850. C1063ACU, Buenos Aires (Argentina); Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral Paz 1499, B1650KNA, San Martin (Argentina); Custo, Graciela, E-mail: custo@cnea.gov.a [Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral Paz 1499, B1650KNA, San Martin (Argentina); Barrio, Nestor, E-mail: nbarrio@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina); Burucua, Jose, E-mail: gburucua@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina); Boeykens, Susana [Universidad de Buenos Aires, Facultad de Ingenieria, Paseo Colon 850. C1063ACU, Buenos Aires (Argentina); Marte, Fernando, E-mail: fmarte@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina)

    2010-09-15

    This article describes the study carried out on a series of oil paintings on canvas from the eighteenth century that were restored at Centro de Produccion e Investigacion en Restauracion y Conservacion Artistica y Bibliografica - Tarea (CEIRCAB-Tarea), Buenos Aires, Argentina: the San Pedro Gonzalez Telmo Sibyls. Experimental study was undertaken to identify inorganic pigments and the technique used in their confection; and, in this way, try to add information about their local origin. Therefore special emphasis was put to infer technologies used in the manufacturing of these paintings. Elemental analysis was performed by total reflection X-ray fluorescence spectrometry (TXRF) and complemented by optical and polarized light microscopy. Microsampling was carefully done over areas of the paintings which were damaged and where a small additional loss will not be noticed. This investigation has shown that a variety of pigments were used, namely earth pigments (red and yellow ochres), white lead, vermilion, etc., and they were used either pure or in mixtures. This characterization helped conservators in their decisions regarding a better understanding of the deterioration processes. In addition, this research about the material composition allowed the art historians and restorers the possibility to obtain information about where, when or by whom The San Pedro Gonzalez Telmo Sibyls may have been painted.

  6. Trace metal determinations by total-reflection x-ray fluorescence analysis in the open Atlantic Ocean

    International Nuclear Information System (INIS)

    Schmidt, D.; Gerwinski, W.; Radke, I.

    1993-01-01

    The Intergovernmental Oceanographic Commission (IOC), as a major component of its programme ''Global Investigation of Pollution in the Marine Environment'' (GIPME), maintains a long-standing project on ''Open Ocean Baseline Studies of Trace Contaminants''. Initially, the Atlantic Ocean and trace metals were selected. Four deep-water stations in the Cape Basin, Angola Basin, Cape Verde Abyssal Plain and Seine Abyssal Plain were regularly sampled for at least 36 depths. Additional samples were taken between stations. Samples were distributed to participants and a similar number of additional laboratories. As a central part of our own contribution to the project, we determined the trace heavy metals manganese, nickel, copper, zinc and lead and the lighter selenium by total-reflection X-ray fluorescence analysis. For the TXRF, the pre-enrichment of the trace metals and the separation from the salt matrix were performed by complexation with sodium dibenzyldithiocarbamate and reverse-phase chromatography. Generally, very low levels of trace elements were found in filtered and unfiltered water samples from these remote areas of the open Atlantic Ocean. Typical examples of the distributions of trace metal concentrations on depth profiles from the four deep-water stations as well as intercomparisons between the stations are presented. (author)

  7. Elemental concentration analysis in the brain of young and old Wistar rats by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Serpa, Renata F.B.; Jesus, Edgar F.O. de; Lopes, Ricardo T.; Anjos, Marcelino J. dos; Carmo, Maria G.T. do; Rocha, Monica S.; Moreira, Silvana; Martinez, Ana M.B.

    2007-01-01

    It is well known that aging is associated with neurobehavioral deficits. The aging process of human brain is characterized by progressive neuronal loss. Furthermore, certain brain areas are more vulnerable to neuronal degeneration than others, reflecting an altered resistance to stress of the tissue itself and/or the lack of adequate immunological defense mechanisms in these regions. About the elemental levels in the brain, it is known that the excess ou deficiency of some elements are toxic for human healthy, being also related to several neurodegenerative diseases. In this way, the main goal of this work was to determine the elemental concentration in the hippocampus of young and old male (n = 10) and female (n = 10) Wistar rats by total reflection X-ray fluorescence spectrometry with synchrotron radiation (SR-TXRF). These measurements were carried out at XRF beam line at Light Synchrotron Brazilian Laboratory, Campinas, Brazil. About the results, we could observe that Al, Fe, Cu, Zn and Br levels were higher in the hippocampus of the old female rats than the young ones. On the other hand, only Cu levels were higher in the hippocampus of the old male rats than the young ones. Therefore, the aging of the hippocampus of the female rats can be characterized by an accumulate for Al, Fe, Cu, Zn and Br. The excess in these elements levels are also associated with several neurodegenerative disorders, such as Alzheimer' disease, Parkinson's disease and Huntington's disease. (author)

  8. Inorganic pigment study of the San Pedro Gonzalez Telmo Sibyls using total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Custo, Graciela; Barrio, Nestor; Burucua, Jose; Boeykens, Susana; Marte, Fernando

    2010-01-01

    This article describes the study carried out on a series of oil paintings on canvas from the eighteenth century that were restored at Centro de Produccion e Investigacion en Restauracion y Conservacion Artistica y Bibliografica - Tarea (CEIRCAB-Tarea), Buenos Aires, Argentina: the San Pedro Gonzalez Telmo Sibyls. Experimental study was undertaken to identify inorganic pigments and the technique used in their confection; and, in this way, try to add information about their local origin. Therefore special emphasis was put to infer technologies used in the manufacturing of these paintings. Elemental analysis was performed by total reflection X-ray fluorescence spectrometry (TXRF) and complemented by optical and polarized light microscopy. Microsampling was carefully done over areas of the paintings which were damaged and where a small additional loss will not be noticed. This investigation has shown that a variety of pigments were used, namely earth pigments (red and yellow ochres), white lead, vermilion, etc., and they were used either pure or in mixtures. This characterization helped conservators in their decisions regarding a better understanding of the deterioration processes. In addition, this research about the material composition allowed the art historians and restorers the possibility to obtain information about where, when or by whom The San Pedro Gonzalez Telmo Sibyls may have been painted.

  9. Total reflection X-ray fluorescence applied to the chemical elements analysis of the mate tea infusion (Ilex-paraguariensis)

    International Nuclear Information System (INIS)

    Lopes, Fabio; Appoloni, Carlos R.; Cunha, Richard M. da Silva e; Nascimento Filho, Virgilio Franco do

    2002-01-01

    The purpose was to evaluate simultaneously the chemical element concentrations from K to Sr (19≤Z≤38) range in six samples of mate tea (Ilex paraguariensis) infusion, commercially available in Paraguay and South of Brazil. The chemical analysis of this beverage has a great nutritional importance for the native people of these areas, due to their large daily consumption. For the determination of these elements the dry-ashing and total reflection X-rays fluorescence (TXRF) were used. The methodology showed limits of detection among 81 ng.mL-1 for K to 10 ng.mL -1 for Zn. Six infusion samples were prepared in triplicate, and the concentration was 3,8 to 10,2 μg.mL -1 for K, Ca and Mn, 0,21 to 1,07 μg. mL -1 for Fe and Zn and 0.03 to 0,17 μg.mL -1 for Ni, Cu, Br, Rb and Sr. The Mn and Ni concentrations are above the maximum permissible values for drinking water established by World Health Organization and Brazilian legislation (these organisms do not regulate the maximum permissible values for chemical elements in mate tea infusion). (author)

  10. Element determination in natural biofilms of mine drainage water by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Mages, Margarete; Tuempling, Wolf von Jr.; Veen, Andrea van der; Baborowski, Martina

    2006-01-01

    Human impacts like mining activities lead to higher element concentration in surface waters. For different pollution levels, the consequences for aquatic organisms are not yet investigated in detail. Therefore, the aim of this investigation is to determine the influence of mining affected surface waters on biofilms. Elements like heavy metals can be absorbed on cell walls and on polymeric substances or enter the cytoplasm of the cells. Thus, they are important for the optimization of industrial biotechnological processes and the environmental biotechnology. Beyond this, biofilms can also play an important role in wastewater treatment processes and serve as bioindicators in the aquatic environment. The presented total reflection X-ray fluorescence spectroscopic investigation was performed to compare the element accumulation behavior of biofilms grown on natural or on artificial materials of drainage water affected by former copper mining activities. A high salt and heavy metal pollution is characteristic for the drainage water. For an assessment of these results, samples from stream Schlenze upstream the confluence with the drainage water, a small tributary of the Saale River in central Germany, were analyzed, too

  11. Detection and quantitative determination of heavy metals in electronic cigarette refill liquids using Total Reflection X-ray Fluorescence Spectrometry.

    Science.gov (United States)

    Kamilari, Eleni; Farsalinos, Konstantinos; Poulas, Konstantinos; Kontoyannis, Christos G; Orkoula, Malvina G

    2018-06-01

    Electronic cigarettes are considered healthier alternatives to conventional cigarettes containing tobacco. They produce vapor through heating of the refill liquids (e-liquids) which consist of propylene glycol, vegetable glycerin, nicotine (in various concentrations), water and flavoring agents. Heavy metals may enter the refill liquid during the production, posing a risk for consumer's health due to their toxicity. The objective of the present study was the development of a methodology for the detection and quantitative analysis of cadmium (Cd), lead (Pb), nickel (Ni), copper (Cu), arsenic (As) and chromium (Cr), employing Total Reflection X-Ray Fluorescence Spectroscopy (TXRF) as an alternative technique to ICP-MS or ICP-OES commonly used for this type of analysis. TXRF was chosen due to its advantages, which include short analysis time, promptness, simultaneous multi-element analysis capability and minimum sample preparation, low purchase and operational cost. The proposed methodology was applied to a large number of electronic cigarette liquids commercially available, as well as their constituents, in order to evaluate their safety. TXRF may be a valuable tool for probing heavy metals in electronic cigarette refill liquids to serve for the protection of human health. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Total reflection x-ray fluorescence spectroscopy as a tool for evaluation of iron concentration in ferrofluids and yeast samples

    International Nuclear Information System (INIS)

    Kulesh, N.A.; Novoselova, I.P.; Safronov, A.P.; Beketov, I.V.; Samatov, O.M.; Kurlyandskaya, G.V.; Morozova, M.; Denisova, T.P.

    2016-01-01

    In this study, total reflection x-ray fluorescent (TXRF) spectrometry was applied for the evaluation of iron concentration in ferrofluids and biological samples containing iron oxide magnetic nanoparticles obtained by the laser target evaporation technique. Suspensions of maghemite nanoparticles of different concentrations were used to estimate the limitation of the method for the evaluation of nanoparticle concentration in the range of 1–5000 ppm in absence of organic matrix. Samples of single-cell yeasts grown in the nutrient media containing maghemite nanoparticles were used to study the nanoparticle absorption mechanism. The obtained results were analyzed in terms of applicability of TXRF for quantitative analysis in a wide range of iron oxide nanoparticle concentrations for biological samples and ferrofluids with a simple established protocol of specimen preparation. - Highlights: • Ferrofluids and yeasts samples were analysed by TXRF spectroscopy. • Simple protocol for iron quantification by means of TXRF was proposed. • Results were combined with magnetic, structural, and morphological characterization. • Preliminary conclusion on nanoparticles uptake mechanism was made.

  13. Impact of Total, Internal and External Government Debt on Interest Rate in Pakistan

    OpenAIRE

    Perveen, Asma; Munir, Kashif

    2017-01-01

    The objective of the study is to examine impact of total, internal and external government debt on nominal interest rate in Pakistan. To attain these objectives, the study used annual time series data from 1973 to 2016. The study used loanable fund theory as theoretical model and ARDL bound testing approach for cointegration and Granger causality test to estimate the results. The results of the study found negative relation between total government debt, external debt and nominal interest rat...

  14. Versatile microfluidic total internal reflection (TIR)-based devices: application to microbeads velocity measurement and single molecule detection with upright and inverted microscope.

    Science.gov (United States)

    Le, Nam Cao Hoai; Yokokawa, Ryuji; Dao, Dzung Viet; Nguyen, Thien Duy; Wells, John C; Sugiyama, Susumu

    2009-01-21

    A poly(dimethylsiloxane) (PDMS) chip for Total Internal Reflection (TIR)-based imaging and detection has been developed using Si bulk micromachining and PDMS casting. In this paper, we report the applications of the chip on both inverted and upright fluorescent microscopes and confirm that two types of sample delivery platforms, PDMS microchannel and glass microchannel, can be easily integrated depending on the magnification of an objective lens needed to visualize a sample. Although any device configuration can be achievable, here we performed two experiments to demonstrate the versatility of the microfluidic TIR-based devices. The first experiment was velocity measurement of Nile red microbeads with nominal diameter of 500 nm in a pressure-driven flow. The time-sequenced fluorescent images of microbeads, illuminated by an evanescent field, were cross-correlated by a Particle Image Velocimetry (PIV) program to obtain near-wall velocity field of the microbeads at various flow rates from 500 nl/min to 3000 nl/min. We then evaluated the capabilities of the device for Single Molecule Detection (SMD) of fluorescently labeled DNA molecules from 30 bp to 48.5 kbp and confirm that DNA molecules as short as 1105 bp were detectable. Our versatile, integrated device could provide low-cost and fast accessibility to Total Internal Reflection Fluorescent Microscopy (TIRFM) on both conventional upright and inverted microscopes. It could also be a useful component in a Micro-Total Analysis System (micro-TAS) to analyze nanoparticles or biomolecules near-wall transport or motion.

  15. An Arduino-Based Experiment Designed to Clarify the Transition to Total Internal Reflection

    Science.gov (United States)

    Atkin, Keith

    2018-01-01

    The topic of refraction and reflection of light at the boundary of transparent media is a fundamentally important one. The special case of total internal reflection is however commonly misrepresented in elementary textbooks. This paper addresses the problem and describes an experimental procedure for measuring and displaying reflected and…

  16. Analysis in crab tissues and in sediment of estuary from Iguape (Sao Paulo, Brazil) by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Salvador, Marcos J.; Sawazaki, David T.A.; Zucchi, Orgheda L.A. Domingues; Vives, Ana Elisa S. de; Hattori, Gustavo Y.

    2007-01-01

    We report the use of Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF) as a technique for macro, micro and trace elements determination in the tissues of the crab Ulcides cordatus and in the sediments from the Iguape estuary (Sao Paulo, Brazil) for environmental pollution control and toxicological evaluation. The analyses were performed on the U. cordatus (muscles and hepatopancreas) and on sediments from 24 sites of the Iguape estuary (Sao Paulo, Brazil). Tissues and sediments samples were analyzed by SRTXRF after digestion in an open system, using Ga as internal standard. Potassium (K), Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Sr, and Ba were the elements detected in crab hepatopancreas at concentration ranging from 0.516 (Mn) to 2061 (K) mug/g. Muscles samples presented the elements K, Ca, Ti, V, Cr, Fe, Ni, Cu, Zn, Br and Sr at concentrations ranging from 0.043 (Ni) to 1917 (K) mug/g. Potassium (K), Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr, Sn, Ce, and Pb were the elements detected in the sediment samples with concentration between 3.8 (Cu) and 14628 (Fe)mug/g. (author)

  17. Analysis in crab tissues and in sediment of estuary from Iguape (Sao Paulo, Brazil) by total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Salvador, Marcos J. [Universidade do Vale do Paraiba (UNIVAP), Sao Jose dos Campos, SP (Brazil)], E-mail: mjsalvador1531@yahoo.com.br; Sawazaki, David T.A.; Zucchi, Orgheda L.A. Domingues [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas], E-mail: david_tatsuo@hotmail.com, E-mail: olzucchi@fcfrp.usp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo], E-mail: aesvives@unimep.br; Hattori, Gustavo Y. [Universidade Federal do Amazonas, Benjamin Constant (Brazil). Faculdade de Ciencias Agrarias], E-mail: hattori@ufam.edu.br

    2007-07-01

    We report the use of Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF) as a technique for macro, micro and trace elements determination in the tissues of the crab Ulcides cordatus and in the sediments from the Iguape estuary (Sao Paulo, Brazil) for environmental pollution control and toxicological evaluation. The analyses were performed on the U. cordatus (muscles and hepatopancreas) and on sediments from 24 sites of the Iguape estuary (Sao Paulo, Brazil). Tissues and sediments samples were analyzed by SRTXRF after digestion in an open system, using Ga as internal standard. Potassium (K), Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Sr, and Ba were the elements detected in crab hepatopancreas at concentration ranging from 0.516 (Mn) to 2061 (K) mug/g. Muscles samples presented the elements K, Ca, Ti, V, Cr, Fe, Ni, Cu, Zn, Br and Sr at concentrations ranging from 0.043 (Ni) to 1917 (K) mug/g. Potassium (K), Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr, Sn, Ce, and Pb were the elements detected in the sediment samples with concentration between 3.8 (Cu) and 14628 (Fe)mug/g. (author)

  18. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy; Determinacion de plomo en esmaltado de barro por Fluorescencia de rayos X en reflexion total y Microscopia Electronica de Barrido

    Energy Technology Data Exchange (ETDEWEB)

    Zarazua O, G.; Carapia M, L. [Instituto Nacional de Investigaciones Nucleares, C.P. 52045 Estado de Mexico (Mexico)

    2000-07-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  19. Use of total-reflection x-ray fluorescence in search of a biomonitor for environmental pollution in Vietnam

    International Nuclear Information System (INIS)

    Boman, J.; Wagner, A.; Brauer, H.; Viet Binh, D.

    2000-01-01

    The concentration of trace elements in tissues of several animals collected in the Ha Nam province, about 25 km south of Hanoi, Vietnam, has been investigated using total-reflection x-ray fluorescence (TXRF). With this study we wanted to address whether any of the animals were possible candidates for being bio-monitors for the pollution situation in a selected area of Vietnam. We also aim to compare the measured trace element concentrations to those representative to other provinces in Vietnam as well as to other parts of the world. An extensive bio-diversity of animals exists in Vietnam, where many of them play an important economic role in the agricultural breeding and production. The accumulation process of trace elements is still not known for a large number of animals. The parts of the collected animals chosen for analysis were muscle tissue and liver. The specimens were dried under vacuum and kept frozen. Before the TXRF analysis, the solid and dried samples were digested in nitric acid. The analysis was made at the Department of Physics at Chalmers University of Technology and Goeteborg University, Sweden, where a TXRF spectrometer has been developed by the Environmental Physics group. The results show that there could be a large variation in the concentration of trace elements, not only between the different animals but also between tissue parts of the same animal. Obviously, when selecting an organism to be used as a bio-monitor, other factors than the mere concentration of trace elements must be considered. (author)

  20. Determination of As concentration in earthworm coelomic fluid extracts by total-reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Allegretta, Ignazio; Porfido, Carlo; Panzarino, Onofrio; Fontanella, Maria Chiara; Beone, Gian Maria; Spagnuolo, Matteo; Terzano, Roberto

    2017-04-01

    Earthworms are often used as sentinel organisms to study As bioavailability in polluted soils. Arsenic in earthworms is mainly sequestrated in the coelomic fluids whose As content can therefore be used to asses As bioavalability. In this work, a method for determining As concentration in coelomic fluid extracts using total-reflection X-ray fluorescence spectrometry (TXRF) is presented. For this purpose coelomic fluid extracts from earthworms living in three polluted soils and one non-polluted (control) soil have been collected and analysed. A very simple sample preparation was implemented, consisting of a dilution of the extracts with polyvinyl alcohol (PVA) using a 1:8 ratio and dropwise deposition of the sample on the reflector. A detection limit of 0.2 μg/l and quantification limit of 0.6 μg/l was obtained in the diluted samples, corresponding to 2 μg/l and 6 μg/l in the coelomic fluid extracts, respectively. This allowed to quantify As concentration in coelomic fluids extracted from earthworms living in soils polluted with As at concentrations higher than 20 mg/kg (considered as a pollution threshold for agricultural soils). The TXRF method has been validated by comparison with As concentrations in standards and by analysing the same samples by ICP-MS, after acid digestion of the sample. The low limit of detection, the proven reliability of the method and the little sample preparation make TXRF a suitable, cost-efficient and "green" technique for the analysis of As in earthworm coelomic fluid extracts for bioavailability studies.

  1. Determination of trace elements in freshwater rotifers and ciliates by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Woelfl, S.; Óvári, M.; Nimptsch, J.; Neu, T. R.; Mages, M.

    2016-02-01

    Element determination in plankton is important for the assessment of metal contamination of aquatic environments. Until recently, it has been difficult to determine elemental content in rotifers or ciliates derived from natural plankton samples because of the difficulty in handling and separation of these fragile organisms. The aim of this study was to evaluate methods for separation of rotifers and large ciliates from natural plankton samples (μg range dry weight) and subsequent analysis of their elemental content using total-reflection X-ray fluorescence spectrometry (TXRF). Plankton samples were collected from different aquatic environments (three lakes, one river) in Chile, Argentina and Hungary. From one to eighty specimens of five rotifer species (Brachionus calyciflorus, Brachionus falcatus, Asplanchna sieboldii, Asplanchna sp., Philodina sp.) and four to twelve specimens of one large ciliate (Stentor amethystinus) were prepared according to the dry method originally developed for microcrustaceans, and analysed by TRXF following in situ microdigestion. Our results demonstrated that it possible to process these small and fragile organisms (individual dry mass: 0.17-9.39 μg ind- 1) via careful washing and preparation procedures. We found species-dependent differences of the element mass fractions for some of the elements studied (Cr, Mn, Fe, Ni, Cu, Zn, As, Pb), especially for Cu, Fe and Mn. One large rotifer species (A. sieboldii) also showed a negative correlation between individual dry weight and the element content for Pb, Ni and Cr. We conclude that our application of the in situ microdigestion-TRXF method is suitable even for rotifers and ciliates, greatly expanding the possibilities for use of plankton in biomonitoring of metal contamination in aquatic environments.

  2. Application of CO2 Snow Jet Cleaning in Conjunction with Laboratory Based Total Reflection X-Ray Fluorescence

    Science.gov (United States)

    Schmeling, M.; Burnett, D. S.; Allton, J. H.; Rodriquez, M.; Tripa, C. E.; Veryovkin, I. V.

    2013-01-01

    The Genesis mission was the first mission returning solar material to Earth since the Apollo program [1,2]. Unfortunately the return of the space craft on September 8, 2004 resulted in a crash landing, which shattered the samples into small fragments and exposed them to desert soil and other debris. Thus only small fragments of the original collectors are available, each having different degrees of surface contamination. Thorough surface cleaning is required to allow for subsequent analysis of solar wind material embedded within. An initial cleaning procedure was developed in coordination with Johnson Space Center which focused on removing larger sized particulates and a thin film organic contamination acquired during collection in space [3]. However, many of the samples have additional residues and more rigorous and/or innovative cleaning steps might be necessary. These cleaning steps must affect only the surface to avoid leaching and re-distribution of solar wind material from the bulk of the collectors. To aid in development and identification of the most appropriate cleaning procedures each sample has to be thoroughly inspected before and after each cleaning step. Laboratory based total reflection X-ray fluorescence (TXRF) spectrometry lends itself to this task as it is a non-destructive and surface sensitive analytical method permitting analysis of elements from aluminum onward present at and near the surface of a flat substrate [4]. The suitability of TXRF has been demonstrated for several Genesis solar wind samples before and after various cleaning methods including acid treatment, gas cluster ion beam, and CO2 snow jet [5 - 7]. The latter one is non-invasive and did show some promise on one sample [5]. To investigate the feasibility of CO2 snow jet cleaning further, several flown Genesis samples were selected to be characterized before and after CO2 snow application with sample 61052 being discussed below.

  3. On the total irregularity strength of caterpillar with each internal vertex has degree three

    Science.gov (United States)

    Indriati, Diari; Rosyida, Isnaini; Widodo

    2018-04-01

    Let G be a simple, connected and undirected graph with vertex set V and edge set E. A total k-labeling f:V \\cup E\\to \\{1,2,\\ldots,k\\} is defined as totally irregular total k-labeling if the weights of any two different both vertices and edges are distinct. The weight of vertex x is defined as wt(x)=f(x)+{\\sum }xy\\in Ef(xy), while the weight of edge xy is wt(xy)=f(x)+f(xy)+f(y). A minimum k for which G has totally irregular total k-labeling is mentioned as total irregularity strength of G and denoted by ts(G). This paper contains investigation of totally irregular total k-labeling and determination of their total irregularity strengths for caterpillar graphs with each internal vertex between two stars has degree three. The results are ts({S}n,3,n)=\\lceil \\frac{2n}{2}\\rceil, ts({S}n,3,3,n)=\\lceil \\frac{2n+1}{2}\\rceil and ts({S}n,3,3,3,n)=\\lceil \\frac{2n+2}{2}\\rceil for n > 4:

  4. Standardization and determination of the total internal conversion coefficient of In-111.

    Science.gov (United States)

    Matos, Izabela T; Koskinas, Marina F; Nascimento, Tatiane S; Yamazaki, Ione M; Dias, Mauro S

    2014-05-01

    The standardization of (111)In by means of a 4πβ-γ coincidence system, composed of a proportional counter in 4π geometry, coupled to a 20% relative efficiency HPGe crystal, for measuring gamma-rays is presented. The data acquisition was performed by means of the software coincidence system (SCS) and the activity was determined by the extrapolation technique. Two gamma-ray windows were selected: at 171 keV and 245 keV total absorption peaks, allowing the determination of the total internal conversion coefficient for these two gamma transitions. The results were compared with those available in the literature. © 2013 Published by Elsevier Ltd.

  5. Precise shape reconstruction by active pattern in total-internal-reflection-based tactile sensor.

    Science.gov (United States)

    Saga, Satoshi; Taira, Ryosuke; Deguchi, Koichiro

    2014-03-01

    We are developing a total-internal-reflection-based tactile sensor in which the shape is reconstructed using an optical reflection. This sensor consists of silicone rubber, an image pattern, and a camera. It reconstructs the shape of the sensor surface from an image of a pattern reflected at the inner sensor surface by total internal reflection. In this study, we propose precise real-time reconstruction by employing an optimization method. Furthermore, we propose to use active patterns. Deformation of the reflection image causes reconstruction errors. By controlling the image pattern, the sensor reconstructs the surface deformation more precisely. We implement the proposed optimization and active-pattern-based reconstruction methods in a reflection-based tactile sensor, and perform reconstruction experiments using the system. A precise deformation experiment confirms the linearity and precision of the reconstruction.

  6. Total internal reflection second-harmonic generation: probing the alkane water interface

    International Nuclear Information System (INIS)

    Conboy, J.C.; Daschbach, J.L.; Richmond, G.L.

    1994-01-01

    Total internal reflection Second-Harmonic Generation (SHG) has been used to study a series of neat n-alkane/water interfaces. Polarization and incident angular-dependent measurements of the SH response show good agreement with theoretical predictions. Analysis of the incident and polarization angular-dependent SH response allows for determination of the nonlinear optical properties of molecules comprising the interfacial region. Based on Kleinman symmetry, the measured surface nonlinear susceptibilities suggest a high degree of interfacial order for octane and decane with less order indicated by the odd carbon n-alkanes examined, heptane and nonane. The SH response in reflection and transmission has been measured under a Total Internal Reflection (TIR) of the fundamental. The measured nonlinear susceptibilities in each case are found to be identical. (orig.)

  7. Conformation and dynamics of nucleotides in bulges and symmetric internal loops in duplex DNA studied by EPR and fluorescence spectroscopies

    International Nuclear Information System (INIS)

    Cekan, Pavol; Sigurdsson, Snorri Th.

    2012-01-01

    Highlights: ► Bulges and loops were studied by both EPR and fluorescence spectroscopies using the probe Ç/Ç f . ► One-base bulge was in a temperature-dependent equilibrium between looped-out and stacked states. ► Bases in two- and three-base bulges were stacked at all temperatures, resulting in DNA bending. ► Bases were stacked in symmetrical two- to five-base internal loops, according to EPR data. ► Unexpectedly high fluorescence for the smaller loops indicated local structural perturbations. -- Abstract: The dynamics and conformation of base bulges and internal loops in duplex DNA were studied using the bifunctional spectroscopic probe Ç, which becomes fluorescent (Ç f ) upon reduction of the nitroxide functional group, along with EPR and fluorescence spectroscopies. A one-base bulge was in a conformational equilibrium between looped-out and stacked states, the former favored at higher temperature and the latter at lower temperature. Stacking of bulge bases was favored in two- and three-base bulges, independent of temperature, resulting in DNA bending as evidenced by increased fluorescence of Ç f . EPR spectra of Ç-labeled three-, four- and five-base symmetrical interior DNA bulges at 20 °C showed low mobility, indicating that the spin-label was stacked within the loop. The spin-label mobility at 37 °C increased as the loops became larger. A considerable variation in fluorescence between different loops was observed, as well as a temperature-dependence within constructs. Fluorescence unexpectedly increased as the size of the loop decreased at 2 °C. Fluorescence of the smallest loops, where a single T·T mismatch was located between the stem region and the probe, was even larger than for the single strand, indicating a considerable local structural deformation of these loops from regular B-DNA. These results show the value of combining EPR and fluorescence spectroscopy to study non-helical regions of nucleic acids.

  8. Systematic errors in the tables of theoretical total internal conversion coefficients

    International Nuclear Information System (INIS)

    Dragoun, O.; Rysavy, M.

    1992-01-01

    Some of the total internal conversion coefficients presented in widely used tables of Rosel et al (1978 Atom. Data Nucl. Data Tables 21, 291) were found to be erroneous. The errors appear for some low transition energies, all multipolarities, and probably for all elements. The origin of the errors is explained. The subshell conversion coefficients of Rosel et al, where available, agree with our calculations. to within a few percent. (author)

  9. Missed Total Occlusion Due to the Occipital Artery Arising from the Internal Carotid Artery

    International Nuclear Information System (INIS)

    Ustunsoz, Bahri; Gumus, Burcak; Koksal, Ali; Koroglu, Mert; Akhan, Okan

    2007-01-01

    A 56-year-old man was referred for digital subtraction angiography (DSA) with an ultrasound diagnosis of right proximal internal carotid artery (ICA) stenosis for possible carotid artery stenting. DSA revealed total occlusion of the ICA and an occipital artery arising from the stump and simulating continuation of the ICA. An ascending pharyngeal artery also arose from the same occipital artery. This case is of interest because this is a rare variation besides being a cause of misdiagnosis at carotid ultrasound

  10. Total reflection x-ray fluorescence (TXRF) - a tool to obtain information about different air masses and air pollution

    International Nuclear Information System (INIS)

    Schmeling, M.

    2000-01-01

    Aerosols are solid particles dissolved in the atmosphere and have strong influence in the earth climate. Their solid surfaces are the only atmospheric medium for condensation of water leading to cloud formation and ultimately to precipitation. Besides their role in cloud formation, the elemental composition of aerosols reveals useful information about air masses and their transport patterns as well as air pollution. The elemental composition can be considered like a fingerprint of an air mass telling the story about its origin and fate. The presence of Al, Ti and Fe for instance indicates a source located in a highly exposed soil or often desert region, whereas Ni, V and Pb can be traced back to anthropogenic activities like fuel combustion or industrial processes. Other important source regions are the oceans, which emit the main aerosol constituents Na, Cl, and S. The concentrations of these elements in the atmosphere are extremely low and long sampling times are necessary to gain reliable results with most of the common analysis techniques. In contrast to this total reflection x-ray fluorescence (TXRF), as a technique capable to cope with tiny sample amounts, offers the unique possibility to reduce collection times to a minimum of minutes to hours. Such short sampling times in turn render it possible to monitor different air masses either passing through a ground based station or -in the ideal case- flown into by a small research aircraft. Different aerosol samples were taken by aircraft during the second aerosol characterization experiment (ACE-2) with sampling times ranging from 15 minutes up to one hour. These filter samples were analyzed by TXRF for trace elements subsequently. Together with background information about back trajectories and size distribution covering the time of sampling the presence of different air masses could be detected. In another project, short-term samples in the Chicago/Lake Michigan area are collected to study the air mass

  11. Exploring the Pattern of Internal Communication in Total Quality Management Implementation in Manufacturing Companies

    Directory of Open Access Journals (Sweden)

    Samsudin Sharina

    2017-01-01

    Full Text Available Communication is an important aspect of organizational dynamic process and it is irrefutable one of the critical success factors of the Total Quality Management (TQM implementation. Although there are increasing awareness concerning the importance of internal organizational communication, knowledge appears to have rarely translated into practice or there is lack of guidance to effectively practicing it. Therefore, a study was proposed to investigate the pattern of internal communication practice in TQM implementation. This paper concerns on focusing into internal communication practices in TQM implementation factors and the communication patterns in terms of message forms and mediums of communication to convey TQM messages. Reliability and Factor analysis were carried out to confirm items that form each factor in internal communication in TQM implementation. Based on the analysis of survey questionnaires distributed to 104 large manufacturing companies implementing TQM in Malaysia, it was found that there are certain communication patterns practice by the management when conveying and disseminating TQM messages, but they have no specific guidelines. Therefore, the internal communication practices are not well planned. Finally, it is suggested that further research should be carried out to explain clearly the role and strategy of communication on this issue in order to boost the success of TQM implementation particularly in manufacturing company.

  12. Surface characterization of selected polymer thin films by total-reflection x-ray fluorescence spectroscopy and x-ray reflectivity

    International Nuclear Information System (INIS)

    Innis, Vallerie Ann A.

    2006-01-01

    Development of available x-ray characterizations tools for grazing incidence techniques was done to be able to probe nano-size thin films. Alignment of a Philips x-ray powder diffractometer was improved to let it perform as an x-ray reflectometer. X-ray reflectometry was coupled with total-reflection x-ray fluorescence spectroscopy. Evaluation of the performance of this grazing incidence techniques was done by preparing polymer thin films of carboxymethylcellulose, carrageenan and polyvinylpyrrolidone (PVP). The thickness of the films were varied by varying the process parameters such as concentration, spin speed and spin time. Angle-dispersive total-reflection x-ray fluorescence spectroscopy profiles of three films showed film formation only in carrageenan and PVP. For both carrageenan and PVP, an increase in concentration yielded a corresponding increase in intensity of the fluorescent or scattered peaks. XRR profiles of carrageenan thin films yielded a mean value for the critical angle close to quartz substrate. Thickness measurements of the prepared carrageenan thin films showed that concentration was the main determinant for final film thickness over the other process parameters. Sulfur fluorescent intensity derived from the TXRF measurement showed a linear relationship with the measured thickness by XRR. For PVP, measured critical angle is lower than quartz. Poor adhesion of the polymer onto the substrate yielded a limited number of thickness measurements made from the XRR profiles. (Author)

  13. Dual fluorescence labeling of surface-exposed and internal proteins in erythrocytes infected with the malaria parasite Plasmodium falciparum

    DEFF Research Database (Denmark)

    Bengtsson, Dominique C; Sowa, Kordai M P; Arnot, David E

    2008-01-01

    There is a need for improved methods for in situ localization of surface proteins on Plasmodium falciparum-infected erythrocytes to help understand how these antigens are trafficked to, and positioned within, the host cell membrane. This protocol for confocal immunofluorescence microscopy combines...... and permeabilization; indirect labeling of the internal antigen using a secondary antibody tagged with a spectrally distinct fluorescent dye; and detection of the differentially labeled antigens using a laser scanning confocal microscope. The protocol can be completed in approximately 7 h. Although the protocol...... surface antigen labeling on live cells with subsequent fixation and permeabilization, which enables antibodies to penetrate the cell and label internal antigens. The key steps of the protocol are as follows: indirect labeling of the surface antigen using a fluorescently tagged secondary antibody; fixation...

  14. Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty: a systematic review.

    Science.gov (United States)

    Panni, Alfredo Schiavone; Ascione, Francesco; Rossini, Marco; Braile, Adriano; Corona, Katia; Vasso, Michele; Hirschmann, Michael T

    2017-12-15

    The aim of this systematic review is to analyze the effect of tibial rotational alignment after total knee arthroplasty (TKA) on clinical outcomes and assess the eventual cut-off values for tibial TKA rotation leading to poor outcomes. A detailed and systematic search from 1997 to 2017 of the Pubmed, Medline, Cochrane Reviews, and the Google Scholar databases was performed using the keyword terms "total knee arthroplasty", "total knee replacement", "tibial alignment", "tibial malalignement", "tibial rotation", "rotational error", "axis", "angle", "tibial malrotation", "clinical outcome", in several combinations. The modified Coleman scoring methodology (mCMS) was used. All the primary TKAs studies analyzing correlation between clinical results and tibial rotation were included. Five articles met the inclusion criteria. A total of 333 arthroplasties were included in this review; 139 had tibial component malalignment, while 194 were in control groups. The mean age of patients was 67.3 (SD 0.57) years. The mean average postoperative follow-up delay was 34.7 months (range 21-70). The mean mCMS score was 59.2 points indicating good methodological quality in the included studies. Functional outcomes were assessed through KSS, OKS, KOOS and VAS, negatively related to tibial internal rotation. Our review confirmed that excessive internal rotation of the tibial TKA component represents a significant risk factor for pain and inferior functional outcomes after TKA (> 10° of internal rotation demonstrated the common value), since external rotation does not affect the results. However, a universal precise cut-off value has not been found in the available literature and there remains a debate about CT rotation assessment and surgical intra-operative landmarks. III.

  15. Quantitative determination of iron, copper, lead, chromium and nickel in electronic waste samples using total reflection x-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Elaseer, A. S.; Musbah, A. S; Ammar, M. M. G.; Salah, M. A.; Aisha, E. A.

    2015-01-01

    Total reflection x-ray fluorescence spectroscopy in conjunction with microwave assisted extraction technique was used for the analysis of twenty electronic waste samples. The analysis was limited to the printed circuit boards of electronic devices. Iron, copper, lead, chromium and nickel were quantitatively determined in the samples. The samples were carefully milled to fine powder and 50mg was digested by acid using microwave digestion procedure. The digested samples solution was spread together with gallium as internal standard on the reflection disk and analyzed. The results showed that the cassette recorder boards contain the highest concentration of iron, lead and nickel. The average concentrations of these metals were 78, 73 and 71g/Kg respectively. Computer boards contained the highest copper average concentration 39g/Kg. the highest chromium average concentration 3.6 g/Kg was in mobile phone boards. Measurements were made using PicoTAX portable x-ray device. the instrument was used for quantitative multi-element analysis. An air cooled x-ray tube (40KV, 1 mA) with Mo target and Be window was used as x-ray source. The optics of the device was a multilayer Ni/C, 17.5 keV, 80% reflectivity provides analysis of elements from Si to Zr (K series) and Rh to U (L series). A Si PIN-diode detector (7mm"2, 195eV) was used for the elements detection. In this study heavy metals average concentration in electronic circuit boards in the in the order of iron (35.25g/kg), copper (21.14g/Kg), lead (16.59g/Kg), nickel (16.01g/Kg) and chromium (1.07g/Kg).(author)

  16. Raman and fluorescence microscopy to study the internalization and dissolution of photosensitizer nanoparticles into living cells

    Science.gov (United States)

    Scalfi-Happ, Claudia; Steiner, Rudolf; Wittig, Rainer; Graefe, Susanna; Ryabova, Anastasia; Loschenov, Victor

    2015-07-01

    In this present study we applied Raman and fluorescence microscopy to investigate the internalisation, cellular distribution and effects on cell metabolism of photosensitizer nanoparticles for photodynamic therapy in fibroblasts and macrophages.

  17. Proceedings of RITE international workshop on valuation; Total eko balance ni kansuru kokusai workshop hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    The RITE International Workshop on Valuation was held in Tokyo and Osaka in February 1996, and eight papers on total ecobalance were reported. In The Field of Impact Assessment, described were constitution and methodology about impact assessment in a wide sense. In LCA Yesterday, Today and Tomorrow, discussed were the historical development and future outlook of LCA. In Standardization of Product Life Cycle Assessment, a survey of the present situation of LCA international standardization was made. In the Relationship between Product Life Cycle Assessment Methodology, considered was the relationship between the goal definition of the product life cycle assessment and the methodological choices. In Valuation in LCA, the present study of LCA was reviewed. Besides, reviews of the LCA study in Japan were made public.

  18. Matrix effect on the detection limit and accuracy in total reflection X-ray fluorescence analysis of trace elements in environmental and biological samples

    International Nuclear Information System (INIS)

    Karjou, J.

    2007-01-01

    The effect of matrix contents on the detection limit of total reflection X-ray fluorescence analysis was experimentally investigated using a set of multielement standard solutions (500 ng/mL of each element) in variable concentrations of NH 4 NO 3 . It was found that high matrix concentration, i.e. 0.1-10% NH 4 NO 3 , had a strong effect on the detection limits for all investigated elements, whereas no effect was observed at lower matrix concentration, i.e. 0-0.1% NH 4 NO 3 . The effect of soil and blood sample masses on the detection limit was also studied. The results showed decreasing the detection limit (in concentration unit, μg/g) with increasing the sample mass. However, the detection limit increased (in mass unit, ng) with increasing sample mass. The optimal blood sample mass of ca. 200 μg was sufficient to improve the detection limit of Se determination by total reflection X-ray fluorescence. The capability of total reflection X-ray fluorescence to analyze different kinds of samples was discussed with respect to the accuracy and detection limits based on certified and reference materials. Direct analysis of unknown water samples from several sources was also presented in this work

  19. Total vs. internal element concentrations in Scots pine needles along a sulphur and metal pollution gradient

    International Nuclear Information System (INIS)

    Rautio, Pasi; Huttunen, Satu

    2003-01-01

    Different methods should be used for foliar analyses of trees used as bioindicators of pollution, than those analyses used in nutritional studies of trees. - Analysis of foliar elements is a commonly used method for studying tree nutrition and for monitoring the impacts of air pollutants on forest ecosystems. Interpretations based on the results of foliar element analysis may, however, be different in nutrition vs. monitoring studies. We studied the impacts of severe sulphur and metal (mainly Cu and Ni) pollution on the element concentrations (Al, Ca, Cu, Fe, K, Mg, Mn, Ni, P, Pb, S and Zn) in Scots pine (Pinus sylvestris L.) foliage along an airborne sulphur and metal pollution gradient. Emphasis was put on determining the contribution of air-borne particles that have accumulated on needle surfaces to the total foliage concentrations. A comparison of two soil extraction methods was carried out in order to obtain a reliable estimate of plant-available element concentrations in the soil. Element concentrations in the soil showed only a weak relationship with internal foliar concentrations. There were no clear differences between the total and internal needle S concentrations along the gradient, whereas at the plot closest to the metal smelter complex the total Cu concentrations in the youngest needles were 1.3-fold and Ni concentrations over 1.6-fold higher than the internal needle concentrations. Chloroform-extracted surface wax was found to have Ni and Cu concentrations of as high as 3000 and 600 μg/g of wax, respectively. Our results suggest that bioindicator studies (e.g. monitoring studies) may require different foliar analysis techniques from those used in studies on the nutritional status of trees

  20. Nonpolarizing beam splitter designed by frustrated total internal reflection inside a glass cube.

    Science.gov (United States)

    Xu, Xueke; Shao, Jianda; Fan, Zhengxiu

    2006-06-20

    A method for the design of an all-dielectric nonpolarizing prism beam splitter utilizing the principle of frustrated total internal reflection is reported. The nonpolarizing condition for a prism beam splitter is discussed, and some single layer design examples are elaborated. The concept can be applied to a wide range of wavelengths and arbitrary transmittance values, and with the help of a computer design program examples of 400-700 nm, T(p)=T(s)=0.5+/-0.01, with incident angles of 45 degrees and 62 degrees are given. In addition, the sensitivity and application of the design are also discussed.

  1. Carbon-dot-based fluorescent turn-on sensor for selectively detecting sulfide anions in totally aqueous media and imaging inside live cells.

    Science.gov (United States)

    Hou, Xianfeng; Zeng, Fang; Du, Fangkai; Wu, Shuizhu

    2013-08-23

    Sulfide anions are generated not only as a byproduct from industrial processes but also in biosystems. Hence, robust fluorescent sensors for detecting sulfide anions which are fast-responding, water soluble and biocompatible are highly desirable. Herein, we report a carbon-dot-based fluorescent sensor, which features excellent water solubility, low cytotoxicity and a short response time. This sensor is based on the ligand/Cu(II) approach so as to achieve fast sensing of sulfide anions. The carbon dot (CD) serves as the fluorophore as well as the anchoring site for the ligands which bind with copper ions. For this CD-based system, as copper ions bind with the ligands which reside on the surface of the CD, the paramagnetic copper ions efficiently quench the fluorescence of the CD, affording the system a turn-off sensor for copper ions. More importantly, the subsequently added sulfide anions can extract Cu(2+) from the system and form very stable CuS with Cu(2+), resulting in fluorescence enhancement and affording the system a turn-on sensor for sulfide anions. This fast-responding and selective sensor can operate in totally aqueous solution or in physiological milieu with a low detection limit of 0.78 μM. It displays good biocompatibility, and excellent cell membrane permeability, and can be used to monitor S(2-) levels in running water and living cells.

  2. Localizing internal friction along the reaction coordinate of protein folding by combining ensemble and single-molecule fluorescence spectroscopy

    Science.gov (United States)

    Borgia, Alessandro; Wensley, Beth G.; Soranno, Andrea; Nettels, Daniel; Borgia, Madeleine B.; Hoffmann, Armin; Pfeil, Shawn H.; Lipman, Everett A.; Clarke, Jane; Schuler, Benjamin

    2012-01-01

    Theory, simulations and experimental results have suggested an important role of internal friction in the kinetics of protein folding. Recent experiments on spectrin domains provided the first evidence for a pronounced contribution of internal friction in proteins that fold on the millisecond timescale. However, it has remained unclear how this contribution is distributed along the reaction and what influence it has on the folding dynamics. Here we use a combination of single-molecule Förster resonance energy transfer, nanosecond fluorescence correlation spectroscopy, microfluidic mixing and denaturant- and viscosity-dependent protein-folding kinetics to probe internal friction in the unfolded state and at the early and late transition states of slow- and fast-folding spectrin domains. We find that the internal friction affecting the folding rates of spectrin domains is highly localized to the early transition state, suggesting an important role of rather specific interactions in the rate-limiting conformational changes. PMID:23149740

  3. Smooth and rough Proteus mirabilis lipopolysaccharides studied by total internal reflection ellipsometry

    International Nuclear Information System (INIS)

    Gleńska-Olender, J.; Dworecki, K.; Sęk, S.; Kwinkowski, M.; Kaca, W.

    2013-01-01

    Total internal reflection ellipsometry (TIRE), a label-free optical detection technique for studying interactions between biomolecules, was used to examine the adsorption of various forms of lipopolysaccharides (LPSs) isolated from Proteus mirabilis S1959, R110, and R45 strains on a gold surface. The thickness of the adsorbed layers was determined by TIRE, with the average values for S1959, R110, and R45 LPS layers being 78 ± 5, 39 ± 3, and 12 ± 2 nm, respectively. The thickness of LPS layers corresponds to the presence and length of O-specific parts in P. mirabilis LPS molecules. Atomic force microscopy was used as a complementary technique for visualizing lipopolysaccharides on the surface. Force measurements seem to confirm the data obtained from TIRE experiments. - Highlights: • Proteus mirabilis lipopolysaccharides were adsorbed on the gold surface. • Thickness of adsorbed layers was determined by total internal reflection ellipsometry. • Atomic force microscopy was used to visualize lipopolysaccharide build-up on gold surface. • Time is important in the evolution of biomolecular film thickness created on gold surface

  4. Smooth and rough Proteus mirabilis lipopolysaccharides studied by total internal reflection ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Gleńska-Olender, J., E-mail: joannaglenska@wp.pl [Institute of Biology, Jan Kochanowski University, 25-406 Kielce (Poland); Świętokrzyski Biobank, Regional Science and Technology Center, 26-060 Chęciny (Poland); Dworecki, K. [Institute of Physics, Jan Kochanowski University, 25-406 Kielce (Poland); Sęk, S. [Department of Chemistry, University of Warsaw, 02-093 Warsaw (Poland); Kwinkowski, M.; Kaca, W. [Institute of Biology, Jan Kochanowski University, 25-406 Kielce (Poland)

    2013-12-02

    Total internal reflection ellipsometry (TIRE), a label-free optical detection technique for studying interactions between biomolecules, was used to examine the adsorption of various forms of lipopolysaccharides (LPSs) isolated from Proteus mirabilis S1959, R110, and R45 strains on a gold surface. The thickness of the adsorbed layers was determined by TIRE, with the average values for S1959, R110, and R45 LPS layers being 78 ± 5, 39 ± 3, and 12 ± 2 nm, respectively. The thickness of LPS layers corresponds to the presence and length of O-specific parts in P. mirabilis LPS molecules. Atomic force microscopy was used as a complementary technique for visualizing lipopolysaccharides on the surface. Force measurements seem to confirm the data obtained from TIRE experiments. - Highlights: • Proteus mirabilis lipopolysaccharides were adsorbed on the gold surface. • Thickness of adsorbed layers was determined by total internal reflection ellipsometry. • Atomic force microscopy was used to visualize lipopolysaccharide build-up on gold surface. • Time is important in the evolution of biomolecular film thickness created on gold surface.

  5. Lysergic acid amide as chemical marker for the total ergot alkaloids in rye flour - Determination by high-performance thin-layer chromatography-fluorescence detection.

    Science.gov (United States)

    Oellig, Claudia

    2017-07-21

    Ergot alkaloids are generally determined by high-performance liquid chromatography (HPLC) coupled to fluorescence detection (FLD) or mass selective detection, analyzing the individual compounds. However, fast and easy screening methods for the determination of the total ergot alkaloid content are more suitable, since for monitoring only the sum of the alkaloids is relevant. The herein presented screening uses lysergic acid amide (LSA) as chemical marker, formed from ergopeptine alkaloids, and ergometrine for the determination of the total ergot alkaloids in rye with high-performance thin-layer chromatography-fluorescence detection (HPTLC-FLD). An ammonium acetate buffered extraction step was followed by liquid-liquid partition for clean-up before the ergopeptine alkaloids were selectively transformed to LSA and analyzed by HPTLC-FLD on silica gel with isopropyl acetate/methanol/water/25% ammonium hydroxide solution (80:10:3.8:1.1, v/v/v/v) as the mobile phase. The enhanced native fluorescence of LSA and unaffected ergometrine was used for quantitation without any interfering matrix. Limits of detection and quantitation were 8 and 26μg LSA/kg rye, which enables the determination of the total ergot alkaloids far below the applied quality criterion limit for rye. Close to 100% recoveries for different rye flours at relevant spiking levels were obtained. Thus, reliable results were guaranteed, and the fast and efficient screening for the total ergot alkaloids in rye offers a rapid alternative to the HPLC analysis of the individual compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Label free imaging of cell-substrate contacts by holographic total internal reflection microscopy.

    Science.gov (United States)

    Mandracchia, Biagio; Gennari, Oriella; Marchesano, Valentina; Paturzo, Melania; Ferraro, Pietro

    2017-09-01

    The study of cell adhesion contacts is pivotal to understand cell mechanics and interaction at substrates or chemical and physical stimuli. We designed and built a HoloTIR microscope for label-free quantitative phase imaging of total internal reflection. Here we show for the first time that HoloTIR is a good choice for label-free study of focal contacts and of cell/substrate interaction as its sensitivity is enhanced in comparison with standard TIR microscopy. Finally, the simplicity of implementation and relative low cost, due to the requirement of less optical components, make HoloTIR a reasonable alternative, or even an addition, to TIRF microscopy for mapping cell/substratum topography. As a proof of concept, we studied the formation of focal contacts of fibroblasts on three substrates with different levels of affinity for cell adhesion. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Superresolution confocal technology for displacement measurements based on total internal reflection.

    Science.gov (United States)

    Kuang, Cuifang; Ali, M Yakut; Hao, Xiang; Wang, Tingting; Liu, Xu

    2010-10-01

    In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.

  8. Superresolution confocal technology for displacement measurements based on total internal reflection

    International Nuclear Information System (INIS)

    Kuang Cuifang; Hao Xiang; Wang Tingting; Liu Xu; Ali, M. Yakut

    2010-01-01

    In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.

  9. Registration of T-2 mycotoxin with total internal reflection ellipsometry and QCM impedance methods.

    Science.gov (United States)

    Nabok, A V; Tsargorodskaya, A; Holloway, A; Starodub, N F; Gojster, O

    2007-01-15

    A sensitive optical method of total internal reflection ellipsometry (TIRE) in conjunction with immune assay approach was exploited for the registration of T-2 mycotoxin in a wide range of concentrations from 100 microg/ml down to 0.15 ng/ml. Association constants of 1.4x10(6) and 1.9x10(7)mol(-1)s for poly- and monoclonal T-2 antibodies, respectively, were evaluated from TIRE kinetic measurements. According to TIRE data fitting, binding of T-2 molecules to antibodies (at saturation) has resulted in the increase in adsorbed layer thickness of 4-5 nm. The QCM impedance measurements data showed anomalously large mass increase and film softening, most likely, due to the binding of large T-2 aggregates to antibodies.

  10. Total internal partition sums for molecular species in the 2000 edition of the HITRAN database

    International Nuclear Information System (INIS)

    Fischer, J.; Gamache, R.R.; Goldman, A.; Rothman, L.S.; Perrin, A.

    2003-01-01

    Total internal partition sums (TIPS) are calculated for all molecular species in the 2000 HITRAN database. In addition, the TIPS for 13 other isotopomers/isotopologues of ozone and carbon dioxide are presented. The calculations address the corrections suggested by Goldman et al. (JQSRT 66 (2000) 455). The calculations consider the temperature range 70-3000 K to be applicable to a variety of remote sensing needs. The method of calculation for each molecular species is stated and comparisons with data from the literature are discussed. A new method of recall for the partition sums, Lagrange 4-point interpolation, is developed. This method, unlike previous versions of the TIPS code, allows all molecular species to be considered

  11. Watch your step! A frustrated total internal reflection approach to forensic footwear imaging.

    Science.gov (United States)

    Needham, J A; Sharp, J S

    2016-02-16

    Forensic image retrieval and processing are vital tools in the fight against crime e.g. during fingerprint capture. However, despite recent advances in machine vision technology and image processing techniques (and contrary to the claims of popular fiction) forensic image retrieval is still widely being performed using outdated practices involving inkpads and paper. Ongoing changes in government policy, increasing crime rates and the reduction of forensic service budgets increasingly require that evidence be gathered and processed more rapidly and efficiently. A consequence of this is that new, low-cost imaging technologies are required to simultaneously increase the quality and throughput of the processing of evidence. This is particularly true in the burgeoning field of forensic footwear analysis, where images of shoe prints are being used to link individuals to crime scenes. Here we describe one such approach based upon frustrated total internal reflection imaging that can be used to acquire images of regions where shoes contact rigid surfaces.

  12. Watch your step! A frustrated total internal reflection approach to forensic footwear imaging

    Science.gov (United States)

    Needham, J. A.; Sharp, J. S.

    2016-02-01

    Forensic image retrieval and processing are vital tools in the fight against crime e.g. during fingerprint capture. However, despite recent advances in machine vision technology and image processing techniques (and contrary to the claims of popular fiction) forensic image retrieval is still widely being performed using outdated practices involving inkpads and paper. Ongoing changes in government policy, increasing crime rates and the reduction of forensic service budgets increasingly require that evidence be gathered and processed more rapidly and efficiently. A consequence of this is that new, low-cost imaging technologies are required to simultaneously increase the quality and throughput of the processing of evidence. This is particularly true in the burgeoning field of forensic footwear analysis, where images of shoe prints are being used to link individuals to crime scenes. Here we describe one such approach based upon frustrated total internal reflection imaging that can be used to acquire images of regions where shoes contact rigid surfaces.

  13. Common-path configuration in total internal reflection digital holography microscopy.

    Science.gov (United States)

    Calabuig, Alejandro; Matrecano, Marcella; Paturzo, Melania; Ferraro, Pietro

    2014-04-15

    Total Internal Reflection Digital Holographic Microscopy (TIRDHM) is recognized to be a powerful tool for retrieving quantitative phase images of cell-substrate interfaces, adhesions, and tissue structures close to the prism surface. In this Letter, we develop an improved TIRDHM system, taking advantage of a refractive index mismatch between the prism and the sample substrate, to allow phase-shifting DH with just a single-beam interferometric configuration. Instead of the traditional off-axis method, phase-shift method is used to retrieve amplitude and phase images in coherent light and TIR modality. Essentially, the substrate-prism interface acts like a beam splitter generating a reference beam, where the phase-shift dependence on the incident angle is exploited in this common-path configuration. With the aim to demonstrate the technique's validity, some experiments are performed to establish the advantage of this compact and simple configuration, in which the reference arm in the setup is avoided.

  14. Exploiting total internal reflection geometry for efficient optical modulation of terahertz light

    Directory of Open Access Journals (Sweden)

    Xudong Liu

    2016-10-01

    Full Text Available Efficient methods to modulate terahertz (THz light are essential for realizing rapid THz imaging and communication applications. Here we report a novel THz modulator which utilizes the evanescent wave in a total internal reflection setup coupled with a conductive interface to enhance the attenuation efficiency of THz light. This approach makes it possible to achieve close to 100% modulation with a small interface conductivity of 12 mS. The frequency dependence of this technique is linked to the optical properties of the materials: a material with close to frequency independent conductivity that is also controllable will result in an achromatic modulation response, and the device performance can be optimized further by tuning the internal reflection angle. In this work, we focus on applying the technique in the terahertz frequency range. Using an LED array with a pump intensity of 475 mW/cm2 to produce carriers in a silicon wafer, we have achieved a modulation depth of up to 99.9% in a broad frequency range of 0.1 THz–0.8 THz. The required pumping power for the generation of the required free carriers is low because the sheet conductivity needed is far less than required for traditional transmission techniques. Consequently, the device can be modulated by an LED making it a very practical, low cost, and scalable solution for THz modulation.

  15. Determination of ultra trace contaminants on silicon wafer surfaces using total-reflection X-ray fluorescence TXRF 'state-of-the-art'

    Science.gov (United States)

    Pahlke, S.; Fabry, L.; Kotz, L.; Mantler, C.; Ehmann, T.

    2001-11-01

    In a well balanced system of highly motivated, well trained personnel and automated equipment, pure reagents and bulk media, cleanrooms and integrated data management, total-reflection X-ray fluorescence (TXRF) can and must contribute to quality assurance and process stability, support and canalize creative engineering by continuous learning about materials and processes. TXRF has the advantage of controlled one-point calibration, a linear dynamic range of three orders of magnitude, high grade of automation in operation and data management, high up-time, and a simple control of data plausibility.

  16. Multielement determination in river-water of Sepetiba Bay tributaries (Brazil) by total reflection X-ray fluorescence using synchrotron radiation

    International Nuclear Information System (INIS)

    Costa, A.C.M.; Castro, C.R.F.; Lopes, R.T.; Anjos, M.J.; Rio de Janeiro State Univ.

    2006-01-01

    Trace elements were determined in the surface waters of tributaries of the Sepetiba Bay, Brazil (Piraque, Ita, Sao Francisco, Guarda, Guandu Mirim, Vala do Sangue and Engenho Novo rivers) by total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). Eighteen trace elements could be determined in the dissolved and the suspended particulate phases: Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr and Pb. The elemental concentration values were compared to the values recommended by the Brazilian legislation. (author)

  17. Total Count of Salmonella typhimurium Coupled on Water Soluble CdSe Quantum Dots by Fluorescence Detection

    Science.gov (United States)

    Feliciano Crespo, Raquel; Perales Perez, Oscar Juan; Ramirez, C.

    2018-05-01

    Health diseases due to the ingestion of water or food contaminated with pathogenic microorganisms are a main health problem around the world. The traditional methods for detecting foodborne pathogens are time-consuming (on the order of days). The development of methods that can help to detect and identify foodborne pathogens with high sensitivity and specificity have been proposed to overcome the limitations of traditional methods. Accordingly, this research is focused on the development of an experimental protocol for a high-sensitivity detection and quantification of bacterial pathogens with reduced detection times. This will lead to the development of a portable and low-cost technology with the opportunity to make onsite detection of pathogenic species. The proposed approach has modified the route reported in the literature; the method proposed is expected to be sensitive enough to detect a low limit of 102 CFU/mL counts of bacteria. The fluorescence-based method was tested in presence of Salmonella typhimurium (ATCC 14020) and Escherichia coli (ATCC 25922). CdSe water-soluble quantum dots (QDs) were synthesized in aqueous phase in presence of thioglycolic acid (TGA) as a capping agent. As-synthesized QDs were characterized by x-ray diffraction, near infrared and Fourier transform infrared spectroscopy, UV-Vis and photoluminescence techniques. Results of the CdSe/TGA-bacteria coupling and the determination of the corresponding quantification profiles (calibration curves) will be presented and discussed.

  18. Dendrochemical patterns of calcium, zinc, and potassium related to internal factors detected by energy dispersive X-ray fluorescence (EDXRF)

    Science.gov (United States)

    Smith, Kevin T.; Balouet, Jean Christophe; Shortle, Walter C.; Chalot, Michel; Beaujard, François; Grudd, Håkan; Vroblesky, Don A.; Burkem, Joel G.

    2014-01-01

    Energy dispersive X-ray fluorescence (EDXRF) provides highly sensitive and precise spatial resolution of cation content in individual annual growth rings in trees. The sensitivity and precision have prompted successful applications to forensic dendrochemistry and the timing of environmental releases of contaminants. These applications have highlighted the need to distinguish dendrochemical effects of internal processes from environmental contamination. Calcium, potassium, and zinc are three marker cations that illustrate the influence of these processes. We found changes in cation chemistry in tree rings potentially due to biomineralization, development of cracks or checks, heartwood/sapwood differentiation, intra-annual processes, and compartmentalization of infection. Distinguishing internal from external processes that affect dendrochemistry will enhance the value of EDXRF for both physiological and forensic investigations.

  19. DEVELOPMENT OF THE MODEL OF AN AUTOMATIC GENERATION OF TOTAL AMOUNTS OF COMMISSIONS IN INTERNATIONAL INTERBANK PAYMENTS

    Directory of Open Access Journals (Sweden)

    Dmitry N. Bolotov

    2013-01-01

    Full Text Available The article deals with the main form of international payment - bank transfer and features when it is charging by banks correspondent fees for transit funds in their correspondent accounts. In order to optimize the cost of expenses for international money transfers there is a need to develop models and toolkit of automatic generation of the total amount of commissions in international interbank settlements. Accordingly, based on graph theory, approach to the construction of the model was developed.

  20. Attenuated total internal reflection infrared microscopy of multilayer plastic packaging foils.

    Science.gov (United States)

    van Dalen, Gerard; Heussen, Patricia C M; den Adel, Ruud; Hoeve, Robert B J

    2007-06-01

    Multilayer plastic foils are important packaging materials that are used to extend the shelf life of food products and drinks. Fourier transform infrared (FT-IR) spectroscopic imaging using attenuated total internal reflection (ATR) can be used for the identification and localization of different layers in multilayer foils. A new type of ATR crystal was used in combination with a linear array detector through which large sample areas (400 x 400 microm(2)) could be imaged with a pixel size of 1.6 microm. The method was tested on laminated plastic packing materials containing 5 to 12 layers. The results of the identification of the different materials using ATR-FT-IR were compared with differential scanning calorimetry (DSC) and the layer thickness of the individual layers measured by ATR-FT-IR was compared with polarized light microscopy (LM) and scanning electron microscopy (SEM). It has been demonstrated that individual layers with a thickness of about 3 microm could be identified in multilayer foils with a total thickness ranging from 100 to 150 microm. The results show a spatial resolution of about 4 microm (measured at wavenumbers ranging from 1000 to 1730 cm(-1)), which is about a factor of two better than can be obtained using transmission FT-IR imaging. An additional advantage of ATR is the ease of sample preparation. A good correspondence was found between visible and FT-IR images. The results of ATR-FT-IR imaging were in agreement with those obtained by LM, SEM, and DSC. ATR-FT-IR is superior to the combination of these techniques because it delivers both spatial and chemical information.

  1. Frustrated total internal reflection in organic light-emitting diodes employing sphere cavity embedded in polystyrene

    International Nuclear Information System (INIS)

    Zhu, Peifen

    2016-01-01

    The light extraction efficiency of top-emitting organic light-emitting diodes (OLEDs) is numerically investigated employing the finite-difference time-domain method. The periodic nanostructures formed by embedding the sphere arrays in polystyrene (PS) are placed on top of OLED to frustrate the total internal reflection at the interface between OLED and free space. These nanostructures serve as an intermediate medium to extract the light out of OLED devices. Efficiently coupling both evanescent waves and propagation waves into spheres and subsequently extracting these light waves out of the sphere is key to achieving high extraction efficiency. By tuning the thickness of PS layer, both of the in-coupling efficiency and out-coupling efficiency are optimized for achieving high light extraction efficiency. Thicker PS layer results in higher in-coupling efficiency in sphere while the thinner PS layer leads to higher out-coupling efficiency. Thus the maximum light extraction is a trade-off between the in-coupling efficiency and out-coupling efficiency. The study shows that light extraction efficiency of 89% can be achieved by embedding 0.90 μm TiO 2 sphere in 0.30 μm PS layer with optimized in-coupling efficiency, out-coupling efficiency and cavity effect. (paper)

  2. Accessible biometrics: A frustrated total internal reflection approach to imaging fingerprints.

    Science.gov (United States)

    Smith, Nathan D; Sharp, James S

    2017-05-01

    Fingerprints are widely used as a means of identifying persons of interest because of the highly individual nature of the spatial distribution and types of features (or minuta) found on the surface of a finger. This individuality has led to their wide application in the comparison of fingerprints found at crime scenes with those taken from known offenders and suspects in custody. However, despite recent advances in machine vision technology and image processing techniques, fingerprint evidence is still widely being collected using outdated practices involving ink and paper - a process that can be both time consuming and expensive. Reduction of forensic service budgets increasingly requires that evidence be gathered and processed more rapidly and efficiently. However, many of the existing digital fingerprint acquisition devices have proven too expensive to roll out on a large scale. As a result new, low-cost imaging technologies are required to increase the quality and throughput of the processing of fingerprint evidence. Here we describe an inexpensive approach to digital fingerprint acquisition that is based upon frustrated total internal reflection imaging. The quality and resolution of the images produced are shown to be as good as those currently acquired using ink and paper based methods. The same imaging technique is also shown to be capable of imaging powdered fingerprints that have been lifted from a crime scene using adhesive tape or gel lifters. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  3. The study of genomic DNA adsorption and subsequent interactions using total internal reflection ellipsometry.

    Science.gov (United States)

    Nabok, Alexei; Tsargorodskaya, Anna; Davis, Frank; Higson, Séamus P J

    2007-10-31

    The adsorption of genomic DNA and subsequent interactions between adsorbed and solvated DNA was studied using a novel sensitive optical method of total internal reflection ellipsometry (TIRE), which combines spectroscopic ellipsometry with surface plasmon resonance (SPR). Single strands of DNA of two species of fish (herring and salmon) were electrostatically adsorbed on top of polyethylenimine films deposited upon gold coated glass slides. The ellipsometric spectra were recorded and data fitting utilized to extract optical parameters (thickness and refractive index) of adsorbed DNA layers. The further adsorption of single stranded DNA from an identical source, i.e. herring ss-DNA on herring ss-DNA or salmon ss-DNA on salmon ss-DNA, on the surface was observed to give rise to substantial film thickness increases at the surface of about 20-21 nm. Conversely adsorption of DNA from alternate species, i.e. salmon ss-DNA on herring ss-DNA or herring ss-DNA on salmon ss-DNA, yielded much smaller changes in thickness of 3-5 nm. AFM studies of the surface roughness of adsorbed layers were in line with the TIRE data.

  4. Analysis of thin-film polymers using attenuated total internal reflection-Raman microspectroscopy.

    Science.gov (United States)

    Tran, Willie; Tisinger, Louis G; Lavalle, Luis E; Sommer, André J

    2015-01-01

    Two methods commonly employed for molecular surface analysis and thin-film analysis of microscopic areas are attenuated total reflection infrared (ATR-IR) microspectroscopy and confocal Raman microspectroscopy. In the former method, the depth of the evanescent probe beam can be controlled by the wavelength of light, the angle of incidence, or the refractive index of the internal reflection element. Because the penetration depth is proportional to the wavelength of light, one could interrogate a smaller film thickness by moving from the mid-infrared region to the visible region employing Raman spectroscopy. The investigation of ATR Raman microspectroscopy, a largely unexplored technique available to Raman microspectroscopy, was carried out. A Renishaw inVia Raman microscope was externally modified and used in conjunction with a solid immersion lens (SIL) to perform ATR Raman experiments. Thin-film polymer samples were analyzed to explore the theoretical sampling depth for experiments conducted without the SIL, with the SIL, and with the SIL using evanescent excitation. The feasibility of micro-ATR Raman was examined by collecting ATR spectra from films whose thickness measured from 200 to 60 nm. Films of these thicknesses were present on a much thicker substrate, and features from the underlying substrate did not become visible until the thin film reached a thickness of 68 nm.

  5. Attenuated total internal reflection Fourier transform infrared spectroscopy: a quantitative approach for kidney stone analysis.

    Science.gov (United States)

    Gulley-Stahl, Heather J; Haas, Jennifer A; Schmidt, Katherine A; Evan, Andrew P; Sommer, André J

    2009-07-01

    The impact of kidney stone disease is significant worldwide, yet methods for quantifying stone components remain limited. A new approach requiring minimal sample preparation for the quantitative analysis of kidney stone components has been investigated utilizing attenuated total internal reflection Fourier transform infrared spectroscopy (ATR-FT-IR). Calcium oxalate monohydrate (COM) and hydroxylapatite (HAP), two of the most common constituents of urinary stones, were used for quantitative analysis. Calibration curves were constructed using integrated band intensities of four infrared absorptions versus concentration (weight %). The correlation coefficients of the calibration curves range from 0.997 to 0.93. The limits of detection range from 0.07 +/- 0.02% COM/HAP where COM is the analyte and HAP is the matrix, to 0.26 +/- 0.07% HAP/COM where HAP is the analyte and COM is the matrix. This study shows that linear calibration curves can be generated for the quantitative analysis of stone mixtures provided the system is well understood especially with respect to particle size.

  6. Near IR Scanning Angle Total Internal Reflection Raman Spectroscopy at Smooth Gold Films

    Energy Technology Data Exchange (ETDEWEB)

    McKee, Kristopher; Meyer, Matthew; Smith, Emily

    2012-04-13

    Total internal reflection (TIR) Raman and reflectivity spectra were collected for nonresonant analytes as a function of incident angle at sapphire or sapphire/smooth 50 nm gold interfaces using 785 nm excitation. For both interfaces, the Raman signal as a function of incident angle is well-modeled by the calculated interfacial mean square electric field (MSEF) relative to the incident field times the thickness of the layer being probed in the Raman measurement (D{sub RS}). The Raman scatter was reproducibly enhanced at the interface containing a gold film relative to the sapphire interface by a factor of 4.3–4.6 for aqueous pyridine or 2.2–3.7 for neat nitrobenzene, depending on the analyzed vibrational mode. The mechanism for the increased Raman signal is the enhanced MSEF at incident angles where propagating surface plasmons are excited in the metal film. The background from the TIR prism was reduced by 89–95% with the addition of the gold film, and the percent relative uncertainty in peak area was reduced from 15 to 1.7% for the 1347 cm–1 mode of nitrobenzene. Single monolayers of benzenethiol (S/N = 6.8) and 4-mercaptopyridine (S/N = 16.5) on gold films were measured by TIR Raman spectroscopy with 785 nm excitation (210 mW) without resonant enhancement in 1 min.

  7. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    Energy Technology Data Exchange (ETDEWEB)

    Pessanha, Sofia [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Carvalho, Maria Luisa, E-mail: luisa@cii.fc.ul.p [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Becker, Maria; Bohlen, Alex von [Institute for analytical Sciences, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund (Germany)

    2010-06-15

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  8. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    International Nuclear Information System (INIS)

    Pessanha, Sofia; Carvalho, Maria Luisa; Becker, Maria; Bohlen, Alex von

    2010-01-01

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  9. Complications of Central Venous Totally Implantable Access Port: Internal Jugular Versus Subclavian Access

    Directory of Open Access Journals (Sweden)

    Pil Young Jung

    Full Text Available Background: Totally implantable access port (TIAP provides reliable, long term vascular access with minimal risk of infection and allows patients normal physical activity. With wide use of ports, new complications have been encountered. We analyzed TIAP related complications and evaluated the outcomes of two different percutaneous routes of access to superior vena cava. Methods: All 172 patients who underwent port insertion with internal jugular approach (Group 1, n = 92 and subclavian approach (Group 2, n = 79 between August 2011 and May 2013 in a single center were analyzed, retrospectively. Medical records were analyzed to compare the outcomes and the occurrence of port related complications between two different percutaneous routes of access to superior vena cava. Results: Median follow-up for TIAP was 278 days (range, 1-1868. Twenty four complications were occurred (14.0%, including pneumothorax (n = 1, 0.6%, migration/malposition (n = 4, 2.3%, pinch-off syndrome (n = 4, 2.3%, malfunction (n = 2, 1.1%, infection (n = 8, 4.7%, and venous thrombosis (n = 5, 2.9%. The overall incidence was 8.7% and 20.3% in each group (p = 0.030. Mechanical complications except infectious and thrombotic complications were more often occurred in group 2 (p = 0.033. The mechanical complication free probability is significantly higher in group 1 (p = 0.040. Conclusions: We suggest that the jugular access should be chosen in patients who need long term catheterization because of high incidence of mechanical complication, such as pinch-off syndrome.

  10. An active one-particle microrheometer: incorporating magnetic tweezers to total internal reflection microscopy.

    Science.gov (United States)

    Gong, Xiangjun; Hua, Li; Wu, Chi; Ngai, To

    2013-03-01

    We present a novel microrheometer by incorporating magnetic tweezers in the total internal reflection microscopy (TIRM) that enables measuring of viscoelastic properties of materials near solid surface. An evanescent wave generated by a solid∕liquid interface in the TIRM is used as the incident light source in the microrheometer. When a probe particle (of a few micrometers diameter) moves near the interface, it can interact with the evanescent field and reflect its position with respect to the interface by the scattered light intensity. The exponential distance dependence of the evanescent field, on the one hand, makes this technique extremely sensitive to small changes from z-fluctuations of the probe (with a resolution of several nanometers), and on the other, it does not require imaging of the probe with high lateral resolution. Another distinct advantage is the high sensitivity in determining the z position of the probe in the absence of any labeling. The incorporated magnetic tweezers enable us to effectively manipulate the distance of the embedded particle from the interface either by a constant or an oscillatory force. The force ramp is easy to implement through a coil current ramp. In this way, the local viscous and elastic properties of a given system under different confinements can therefore be measured by resolving the near-surface particle motion. To test the feasibility of applying this microrheology to soft materials, we measured the viscoelastic properties of sucrose and poly(ethylene glycol) solutions and compared the results to bulk rheometry. In addition, we applied this technique in monitoring the structure and properties of deformable microgel particles near the flat surface.

  11. A new selective fluorene-based fluorescent internal charge transfer (ICT) sensor for sugar alcohols in aqueous solution.

    Science.gov (United States)

    Hosseinzadeh, Rahman; Mohadjerani, Maryam; Pooryousef, Mona

    2016-03-01

    Sugar alcohols, such as sorbitol, are commonly used as a replacement for sucrose in the food industry, applied as starting material for vitamin C synthesis, and involved as one of the causative factors in diabetic complications. Therefore, their detection and quantification in aqueous solution are necessary. The reversible covalent interactions between boronic acids and diols are the basis of efficient methods for the detection of saccharides. Herein, we report a new internal charge transfer (ICT) fluorene-based fluorescent boronic acid sensor (1) 2-[(9,9-dimethyl-9H-fluoren-2-yl-amino)methyl] phenyl boronic acid that shows significant fluorescence changes upon addition of saccharides. The boronic acid has high affinity (K a = 1107.9 M(-1)) and selectivity for sorbitol at pH = 8.31. It showed a linear response toward sorbitol in the concentration range from 1.0 × 10(-5) to 6.0 × 10(-4) mol L(-1) with the detection limit of 7.04 × 10(-6) mol L(-1). Sensor 1 was used to detect sorbitol in real samples with good recovery.

  12. Quantum electrodynamics of the internal source x-ray holographies: Bremsstrahlung, fluorescence, and multiple-energy x-ray holography

    International Nuclear Information System (INIS)

    Miller, G.A.; Sorensen, L.B.

    1997-01-01

    Quantum electrodynamics (QED) is used to derive the differential cross sections measured in the three new experimental internal source ensemble x-ray holographies: bremsstrahlung (BXH), fluorescence (XFH), and multiple-energy (MEXH) x-ray holography. The polarization dependence of the BXH cross section is also obtained. For BXH, we study analytically and numerically the possible effects of the virtual photons and electrons which enter QED calculations in summing over the intermediate states. For the low photon and electron energies used in the current experiments, we show that the virtual intermediate states produce only very small effects. This is because the uncertainty principle limits the distance that the virtual particles can propagate to be much shorter than the separation between the regions of high electron density in the adjacent atoms. We also find that using the asymptotic form of the scattering wave function causes about a 5 10% error for near forward scattering. copyright 1997 The American Physical Society

  13. First combined total reflection X-ray fluorescence and grazing incidence X-ray absorption spectroscopy characterization of aeolian dust archived in Antarctica and Alpine deep ice cores

    Energy Technology Data Exchange (ETDEWEB)

    Cibin, G. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxon OX110DE (United Kingdom); IMONT/EIM, Ente Italiano della Montagna, P.za dei Caprettari 70, 00176 Roma (Italy); Universita' degli Studi di Roma Tre, Dipartimento di Scienze Geologiche, L.go S. Leonardo Murialdo 1, 00146 Roma (Italy)], E-mail: giannantonio.cibin@diamond.ac.uk; Marcelli, A. [INFN - Laboratori Nazionali di Frascati, P.O. Box 13, 00044 Frascati (Roma) (Italy); Maggi, V. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Sala, M. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Universita degli Studi di Milano, Dipartimento di Scienze della Terra ' A. Desio' , Sez. Mineralogia, Via Mangiagalli 34, 20133 Milano (Italy); Marino, F.; Delmonte, B. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Albani, S. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Universita degli Studi di Siena, Dottorato in Scienze Polari, via Laterina 8, 53100 Siena (Italy); Pignotti, S. [IMONT/EIM, Ente Italiano della Montagna, P.za dei Caprettari 70, 00176 Roma (Italy)

    2008-12-15

    Aeolian mineral dust archived in polar and mid latitude ice cores represents a precious proxy for assessing environmental and climatic variations at different timescales. In this respect, the identification of dust mineralogy plays a key role. In this work we performed the first preliminary X-ray absorption spectroscopy (XAS) experiments on mineral dust particles extracted from Antarctic and from Alpine firn cores using grazing incidence geometry at the Fe K-edge. A dedicated high vacuum experimental chamber was set up for normal-incidence and total-reflection X-Ray Fluorescence and Absorption Spectroscopy analyses on minor amounts of mineral materials at the Stanford Synchrotron Radiation Laboratory. Results show that this experimental technique and protocol allows recognizing iron inclusion mineral fraction on insoluble dust in the 1-10 {mu}g range.

  14. Eigenvalue-eigenvector decomposition (EED) analysis of dissimilarity and covariance matrix obtained from total synchronous fluorescence spectral (TSFS) data sets of herbal preparations: Optimizing the classification approach

    Science.gov (United States)

    Tarai, Madhumita; Kumar, Keshav; Divya, O.; Bairi, Partha; Mishra, Kishor Kumar; Mishra, Ashok Kumar

    2017-09-01

    The present work compares the dissimilarity and covariance based unsupervised chemometric classification approaches by taking the total synchronous fluorescence spectroscopy data sets acquired for the cumin and non-cumin based herbal preparations. The conventional decomposition method involves eigenvalue-eigenvector analysis of the covariance of the data set and finds the factors that can explain the overall major sources of variation present in the data set. The conventional approach does this irrespective of the fact that the samples belong to intrinsically different groups and hence leads to poor class separation. The present work shows that classification of such samples can be optimized by performing the eigenvalue-eigenvector decomposition on the pair-wise dissimilarity matrix.

  15. Efficient isotope ratio analysis of uranium particles in swipe samples by total-reflection x-ray fluorescence spectrometry and secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Esaka, Fumitaka; Watanabe, Kazuo; Fukuyama, Hiroyasu; Onodera, Takashi; Esaka, Konomi T.; Magara, Masaaki; Sakurai, Satoshi; Usuda, Shigekazu

    2004-01-01

    A new particle recovery method and a sensitive screening method were developed for subsequent isotope ratio analysis of uranium particles in safeguards swipe samples. The particles in the swipe sample were recovered onto a carrier by means of vacuum suction-impact collection method. When grease coating was applied to the carrier, the recovery efficiency was improved to 48±9%, which is superior to that of conventionally-used ultrasoneration method. Prior to isotope ratio analysis with secondary ion mass spectrometry (SIMS), total reflection X-ray fluorescence spectrometry (TXRF) was applied to screen the sample for the presence of uranium particles. By the use of Si carriers in TXRF analysis, the detection limit of 22 pg was achieved for uranium. By combining these methods with SIMS, the isotope ratios of 235 U/ 238 U for individual uranium particles were efficiently determined. (author)

  16. Application of the total reflection X-ray fluorescence method to the elemental analysis of brain tumors of different types and grades of malignancy

    International Nuclear Information System (INIS)

    Lankosz, M.W.; Grzelak, M.; Ostachowicz, B.; Wandzilak, A.; Szczerbowska-Boruchowska, M.; Wrobel, P.; Radwanska, E.; Adamek, D.

    2014-01-01

    The process of carcinogenesis may influence normal biochemical reactions leading to alterations in the elemental composition of the tissue. Total reflection X-ray fluorescence analysis (TXRF) was applied to the elemental analysis of different brain tumors. The following elements were present in all the neoplastic tissues analyzed: K, Ca, Fe, Cu, Zn and Rb. The results of the analysis showed that the elemental composition of a relatively small fragment of tissue represents satisfactorily the biochemical “signature” of a cancer. On the basis of the element concentrations determined, it was possible to differentiate between some types of brain tumors. - Highlights: • Elemental composition represents the biochemical signature of brain cancer. • The element levels differentiate some types of brain tumors. • TXRF spectrometry is a useful tool for elemental trace analysis of brain cancer

  17. Monitoring environmental pollution of trace elements in tree-rings by synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    International Nuclear Information System (INIS)

    Moreira, Silvana; Vives, Ana Elisa S. de; Brienza, Sandra Maria B.; Medeiros, Jean Gabriel S.; Tomazello Filho, Mario; Zucchi, Orgheda L.A.D.; Nascimento Filho, Virgilio F.

    2005-01-01

    This paper aims to study the environmental pollution in the tree development, as a manner to evaluate its use as bioindicator in urban and country sides. The sample collecting was carry out in Piracicaba city, Sao Paulo State, that presents high level of environmental contamination of the water, soil and air, due industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. It was selected the Caesalpinia peltophoroides ('Sibipiruna') specie because its very used in urban arborization. It was employed the analytical technique named total reflection X-ray fluorescence (TXRF) to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was done in the Brazilian Synchrotron Light Laboratory, using a white beam for excitation and a Si(Li) detector for characteristic X-ray detection. It was quantified the P, K, Ca, Ti, Fe, Sr, Ba e Pb elements. (author)

  18. Confocal total reflection X-ray fluorescence technology based on an elliptical monocapillary and a parallel polycapillary X-ray optics.

    Science.gov (United States)

    Zhu, Yu; Wang, Yabing; Sun, Tianxi; Sun, Xuepeng; Zhang, Xiaoyun; Liu, Zhiguo; Li, Yufei; Zhang, Fengshou

    2018-07-01

    A total reflection X-ray fluorescence (TXRF) spectrometer based on an elliptical monocapillary X-ray lens (MXRL) and a parallel polycapillary X-ray lens (PPXRL) was designed. This TXRF instrument has micro focal spot, low divergence and high intensity of incident X-ray beam. The diameter of the focal spot of MXRL was 16.5 µm, and the divergence of the incident X-ray beam was 3.4 mrad. We applied this TXRF instrument to the micro analysis of a single-layer film containing Ni deposited on a Si substrate by metal vapor vacuum arc ion source. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. First combined total reflection X-ray fluorescence and grazing incidence X-ray absorption spectroscopy characterization of aeolian dust archived in Antarctica and Alpine deep ice cores

    International Nuclear Information System (INIS)

    Cibin, G.; Marcelli, A.; Maggi, V.; Sala, M.; Marino, F.; Delmonte, B.; Albani, S.; Pignotti, S.

    2008-01-01

    Aeolian mineral dust archived in polar and mid latitude ice cores represents a precious proxy for assessing environmental and climatic variations at different timescales. In this respect, the identification of dust mineralogy plays a key role. In this work we performed the first preliminary X-ray absorption spectroscopy (XAS) experiments on mineral dust particles extracted from Antarctic and from Alpine firn cores using grazing incidence geometry at the Fe K-edge. A dedicated high vacuum experimental chamber was set up for normal-incidence and total-reflection X-Ray Fluorescence and Absorption Spectroscopy analyses on minor amounts of mineral materials at the Stanford Synchrotron Radiation Laboratory. Results show that this experimental technique and protocol allows recognizing iron inclusion mineral fraction on insoluble dust in the 1-10 μg range

  20. Portable ultrahigh-vacuum sample storage system for polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp; Nishimura, Yusaku F.; Suzuki, Ryo; Beniya, Atsushi; Isomura, Noritake [Toyota Central R& D Labs., Inc., Yokomichi 41-1, Nagakute, Aichi 480-1192 (Japan); Uehara, Hiromitsu; Asakura, Kiyotaka; Takakusagi, Satoru [Catalysis Research Center, Hokkaido University, Kita 21-10, Sapporo, Hokkaido 001-0021 (Japan); Nimura, Tomoyuki [AVC Co., Ltd., Inada 1450-6, Hitachinaka, Ibaraki 312-0061 (Japan)

    2016-03-15

    A portable ultrahigh-vacuum sample storage system was designed and built to investigate the detailed geometric structures of mass-selected metal clusters on oxide substrates by polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy (PTRF-XAFS). This ultrahigh-vacuum (UHV) sample storage system provides the handover of samples between two different sample manipulating systems. The sample storage system is adaptable for public transportation, facilitating experiments using air-sensitive samples in synchrotron radiation or other quantum beam facilities. The samples were transferred by the developed portable UHV transfer system via a public transportation at a distance over 400 km. The performance of the transfer system was demonstrated by a successful PTRF-XAFS study of Pt{sub 4} clusters deposited on a TiO{sub 2}(110) surface.

  1. Monitoring environmental pollution of trace elements in tree-rings by synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Brienza, Sandra Maria B. [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil) Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Medeiros, Jean Gabriel S.; Tomazello Filho, Mario [Sao Paulo Univ., Piracicaba, SP (Brazil). Escola Superior de Agricultura Luiz de Queiroz]. E-mail: jeangm@esalq.usp.br; mtomazel@esalq.usp.br; Zucchi, Orgheda L.A.D. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio F. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear]. E-mail: virgilio@cena.usp.br

    2005-07-01

    This paper aims to study the environmental pollution in the tree development, as a manner to evaluate its use as bioindicator in urban and country sides. The sample collecting was carry out in Piracicaba city, Sao Paulo State, that presents high level of environmental contamination of the water, soil and air, due industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. It was selected the Caesalpinia peltophoroides ('Sibipiruna') specie because its very used in urban arborization. It was employed the analytical technique named total reflection X-ray fluorescence (TXRF) to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was done in the Brazilian Synchrotron Light Laboratory, using a white beam for excitation and a Si(Li) detector for characteristic X-ray detection. It was quantified the P, K, Ca, Ti, Fe, Sr, Ba e Pb elements. (author)

  2. Eigenvalue-eigenvector decomposition (EED) analysis of dissimilarity and covariance matrix obtained from total synchronous fluorescence spectral (TSFS) data sets of herbal preparations: Optimizing the classification approach.

    Science.gov (United States)

    Tarai, Madhumita; Kumar, Keshav; Divya, O; Bairi, Partha; Mishra, Kishor Kumar; Mishra, Ashok Kumar

    2017-09-05

    The present work compares the dissimilarity and covariance based unsupervised chemometric classification approaches by taking the total synchronous fluorescence spectroscopy data sets acquired for the cumin and non-cumin based herbal preparations. The conventional decomposition method involves eigenvalue-eigenvector analysis of the covariance of the data set and finds the factors that can explain the overall major sources of variation present in the data set. The conventional approach does this irrespective of the fact that the samples belong to intrinsically different groups and hence leads to poor class separation. The present work shows that classification of such samples can be optimized by performing the eigenvalue-eigenvector decomposition on the pair-wise dissimilarity matrix. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Studies and developments for the analysis of products of nuclear reprocessing plants with the help of the X-ray fluorescence analysis on totally reflecting sample holders (TXRF)

    International Nuclear Information System (INIS)

    Diercks, H.; Eggers, I.; Gibau, F.; Haarich, M.; Hastenteufel, S.; Haurand, M.; Knoechel, A.; Salow, H.

    1990-01-01

    Studies with inactive and active simulates of products of nuclear reprocessing plants show the suitability of the X-Ray Fluorescence Analysis on Totally Reflecting Sample Holders (TXRF), to detect the available elements simultaneously by direct measurements of specially prepared thin samples. High dilution enables in the most cases, to avoid working in hot cells and to carry out the analysis in glove boxes. The analysis of uranium products and great amounts of matrix elements containing solutions like LAW and MAW demands the separation of the matrix elements before TXRF measurement. Procedures for this task have been developed. The potential of the new analytical procedure was demonstrated by the analysis of two samples of highly diluted high active wastes. (orig.) With 65 refs., 20 tabs., 81 figs [de

  4. Determination of metals by total reflection X-ray fluorescence and evaluation of toxicity of a river impacted by coal mining in the south of Brazil.

    Science.gov (United States)

    Lattuada, R M; Menezes, C T B; Pavei, P T; Peralba, M C R; Dos Santos, J H Z

    2009-04-30

    Metal (Fe, Mn, Zn, Ni, Cd, and Pb) concentrations in the region of Criciuma (Brazil), a region impacted by coal mining, were determined in water and sediments using total reflection X-ray fluorescence (TXRF) spectroscopy. Samples were collected from the Mãe Luzia River (south Brazil) at five different stations, from the source down to the river mouth (Ararangua estuary). Water and sediment toxicity were also evaluated using bioassays with Daphnia magna as the bioindicator. The metal present in the highest concentrations both in water (1.3-11 mg L(-1)) and in sediments (34-142 mg L(-1)) was iron. Results suggest an influence of coal mining on the aquatic receptors, showing a clear relationship between metal content (mostly Fe) and ecotoxicity.

  5. Trace element analysis of mineral and tap water samples using total reflection x-ray fluorescence (TXRF)

    International Nuclear Information System (INIS)

    Mangala, M.J.; Korir, K.A.; Maina, D.M.; Kinyua, A.M.

    2000-01-01

    Results of trace element analysis by TXRF of tap water and various brands of bottled mineral water samples which are representative of local and imported brands sold in Nairobi are reported. The variation in elemental concentrations in water samples analyzed were as follows: potassium (K) 0.2 to 28.9 μg/ml; calcium (Ca) 2.2 to 120 μg/ml; titanium (Ti) 11 to 60 μg/l; manganese (Mn) 8 to 670 μg/l; iron (Fe) 31 to 540 μg/l; copper (Cu) 8 to 30 μg/l; zinc (Zn) 8 to 4730 μg/l; bromine (Br) 9 to 248 μg/l; rubidium (Rb) 10 to 40 μg/l and strontium (Sr) 10 to 1000 μg/l. Local mineral water samples contain higher levels of trace elements; manganese (Mn), zinc (Zn), bromine (Br), rubidium (Rb) and strontium (Sr) as compared to the imported brands. Principal component analysis of the results revealed three component loading factors clusters for: rubidium (Rb), strontium (Sr) and calcium (Ca); titanium (Ti), iron (Fe), bromine (Br), and zinc (Zn); zinc (Zn), manganese (Mn) and potassium (K) respectively. The percentage of total variance explained by the components was 31.4, 27.3, and 14.8 respectively. In this study, we also found that a limited spread of 5-6 mm for a 10 μl sample was achieved when the quartz sample carrier was dried in a low pressure (300 mbar) oven at 70 o C for 10 hours. (author)

  6. Room temperature trapping of stibine and bismuthine onto quartz substrates coated with nanostructured palladium for total reflection X-ray fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Romero, Vanesa; Costas-Mora, Isabel; Lavilla, Isela; Bendicho, Carlos, E-mail: bendicho@uvigo.es

    2015-05-01

    In this work, a novel method for determining Sb and Bi based on the trapping of their covalent hydrides onto quartz reflectors coated with immobilized palladium nanoparticles (Pd NPs) followed by total reflection X-ray fluorescence (TXRF) analysis is proposed. Pd NPs were synthesized by chemical reduction of the metal precursor using a mixture of water:ethanol as mild reducing agent. Silanization using 3-mercaptopropyltrimethoxysilane (MPTMS) was performed for the immobilization of Pd NPs onto the quartz substrates. Volatile hydrides (stibine and bismuthine) generated by means of a continuous flow system were flushed onto the immobilized Pd NPs and retained by catalytic decomposition. As a result of the high catalytic activity of the nanostructured film, trapping can be performed at ambient temperature with good efficiency. Limits of detection (LODs) were 2.3 and 0.70 μg L{sup −1} for Sb and Bi, respectively. Enrichment factors of 534 and 192 were obtained for Sb and Bi, respectively. The new method was applied for the analysis of several matrices (milk, soil, sediment, cutaneous powder). Recoveries were in the range of 98.4–101% for both elements with a relative standard deviation of 2.5% (N = 5). - Highlights: • A novel method for trapping covalent hydrides of antimony and bismuth is proposed. • Emphasis is placed on the application of Pd nanoparticles as trapping surface. • The nanostructured surface provides high catalytic activity at ambient temperature. • Analysis by total reflection X-ray fluorescence is performed. • Determination of Bi and Sb in different matrices is carried out.

  7. On total irregularity strength of caterpillar graphs with two leaves on each internal vertex

    Science.gov (United States)

    Rosyida, I.; Widodo; Indriati, D.

    2018-04-01

    Let G(V, E) be a graph. A function f from V(G)\\cup E(G) to the set {1, 2, …, k} is said to be a totally irregular total k-labeling of G if the weights of any two different vertices x and y in V (G) satisfy {w}f(x)\

  8. Evaluation of growth tree rings of Tipuana Tipu as biomonitoring of environmental pollution by synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Moreira, Silvana; Geraldo, Simoni Michetti; Canteras, Felippe Benavente

    2013-01-01

    The bioindicators, plants or animals capable to present qualitative and/or quantitative answers, when exposed to pollutant substances. Trees record and incorporate in their log, developed year after year, the impressions of the environment, becoming possible the study of the different environmental changes, including contamination, that have occurred over the life of these trees. The selected species, Tipuana Tipu, of the Leguminosae family, is native of Argentina and Bolivia and was introduced in Brazil as an ornamental plant. It is one of the most common trees in the urban landscaping in Sao Paulo city. The present project has as main objective the determination of the content of potentially toxic elements in samples of growth the tree rings of Tipuana Tipu, previously dated, collected in strategically locations of Sao Paulo, using Synchrotron Radiation Total Reflection X-Ray Fluorescence. Samples were also collected in the Piracicaba (SP), local of little access and small flow traffic. The SR-TXRF analysis was carried out in the X-ray Fluorescence Beamline at the Brazilian Synchrotron Light Source Laboratory, located in Campinas city, Sao Paulo State, Brazil. Some trace elements present concentrations higher than considered as normal in some periods. In this paper the highest value for Pb was 123.54 μg.g -1 considered as threshold value was observed for the period 1998 to 2000 for University of Sao Paulo, Butanta site. For the same period excessive level was also observed for samples collected in Piracicaba city. In Sao Paulo city, sample collected in the campus of University of Sao Paulo (Butanta), showed the highest toxicity, with concentration above the tolerable limit for Ti, Cr and Cu. For the samples collected in Piracicaba city the concentrations of Cr, Ni, Cu, and Pb exceeding the toxicity limits. (author)

  9. Evaluation of growth tree rings of Tipuana Tipu as biomonitoring of environmental pollution by synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana; Geraldo, Simoni Michetti; Canteras, Felippe Benavente, E-mail: silvana@fec.unicamp.br, E-mail: felippe.canteras@gmail.com [Universidade Estadual de Campinas (FEC/UNICAMP), Campinas, SP (Brazil). Dept. de Saneamento e Ambiente

    2013-07-01

    The bioindicators, plants or animals capable to present qualitative and/or quantitative answers, when exposed to pollutant substances. Trees record and incorporate in their log, developed year after year, the impressions of the environment, becoming possible the study of the different environmental changes, including contamination, that have occurred over the life of these trees. The selected species, Tipuana Tipu, of the Leguminosae family, is native of Argentina and Bolivia and was introduced in Brazil as an ornamental plant. It is one of the most common trees in the urban landscaping in Sao Paulo city. The present project has as main objective the determination of the content of potentially toxic elements in samples of growth the tree rings of Tipuana Tipu, previously dated, collected in strategically locations of Sao Paulo, using Synchrotron Radiation Total Reflection X-Ray Fluorescence. Samples were also collected in the Piracicaba (SP), local of little access and small flow traffic. The SR-TXRF analysis was carried out in the X-ray Fluorescence Beamline at the Brazilian Synchrotron Light Source Laboratory, located in Campinas city, Sao Paulo State, Brazil. Some trace elements present concentrations higher than considered as normal in some periods. In this paper the highest value for Pb was 123.54 μg.g{sup -1} considered as threshold value was observed for the period 1998 to 2000 for University of Sao Paulo, Butanta site. For the same period excessive level was also observed for samples collected in Piracicaba city. In Sao Paulo city, sample collected in the campus of University of Sao Paulo (Butanta), showed the highest toxicity, with concentration above the tolerable limit for Ti, Cr and Cu. For the samples collected in Piracicaba city the concentrations of Cr, Ni, Cu, and Pb exceeding the toxicity limits. (author)

  10. Development of Total Reflection X-ray fluorescence spectrometry quantitative methodologies for elemental characterization of building materials and their degradation products

    Science.gov (United States)

    García-Florentino, Cristina; Maguregui, Maite; Marguí, Eva; Torrent, Laura; Queralt, Ignasi; Madariaga, Juan Manuel

    2018-05-01

    In this work, a Total Reflection X-ray fluorescence (TXRF) spectrometry based quantitative methodology for elemental characterization of liquid extracts and solids belonging to old building materials and their degradation products from a building of the beginning of 20th century with a high historic cultural value in Getxo, (Basque Country, North of Spain) is proposed. This quantification strategy can be considered a faster methodology comparing to traditional Energy or Wavelength Dispersive X-ray fluorescence (ED-XRF and WD-XRF) spectrometry based methodologies or other techniques such as Inductively Coupled Plasma Mass Spectrometry (ICP-MS). In particular, two kinds of liquid extracts were analysed: (i) water soluble extracts from different mortars and (ii) acid extracts from mortars, black crusts, and calcium carbonate formations. In order to try to avoid the acid extraction step of the materials and their degradation products, it was also studied the TXRF direct measurement of the powdered solid suspensions in water. With this aim, different parameters such as the deposition volume and the measuring time were studied for each kind of samples. Depending on the quantified element, the limits of detection achieved with the TXRF quantitative methodologies for liquid extracts and solids were set around 0.01-1.2 and 2-200 mg/L respectively. The quantification of K, Ca, Ti, Mn, Fe, Zn, Rb, Sr, Sn and Pb in the liquid extracts was proved to be a faster alternative to other more classic quantification techniques (i.e. ICP-MS), accurate enough to obtain information about the composition of the acidic soluble part of the materials and their degradation products. Regarding the solid samples measured as suspensions, it was quite difficult to obtain stable and repetitive suspensions affecting in this way the accuracy of the results. To cope with this problem, correction factors based on the quantitative results obtained using ED-XRF were calculated to improve the accuracy of

  11. Evaluation of Fe and Zn/Cu ratio in serum of patients with sickle cell anemia by total reflection X-ray fluorescence using synchrotron radiation

    International Nuclear Information System (INIS)

    Canellas, Catarine G.L.; Leitao, Roberta G.; Lopes, Ricardo T.; Bellido, Alfredo Victor B.; Anjos, Marcelino J.

    2011-01-01

    Sickle cell anemia (SCA) is a blood disorder that affects hemoglobin, the protein found in red blood cells that help carry oxygen throughout the body. In this work we have analyzed serum samples from patients with SCA by using total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). The SRTXRF measurements were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo using a polychromatic beam. We have studied forty-three patients aged 18-50 years old, suffering from SCA and Sixty healthy volunteers aged 18-60 years old. It was possible to determine the concentrations of the following elements: P, S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. Student's t-test was applied in order to check whether the two populations (CG x SCA) had the same mean values. It was observed that elemental concentration of P, Cl, K, Fe, Cu, Zn and Br differed significantly (α = 0.05) between groups of healthy subjects and SCA. The concentrations of K, Fe and Cu in the serum samples of patients with SCA were larger 15%, 120 % and 20 %, respectively, when compared with the CG. On the other hand, the concentrations of P (-20 %), Cl (-6 %), Zn (-25 %) and Br (-22 %) were smaller than the values determined for the control group. The serum level Cu/Zn ratio was significantly higher (60%) in the serum samples of patients with SCA group than the CG. So, the Cu/Zn ratio can be used as an adjuvant index in enhancement for diagnosis of SCA. There are evidences of an association among Fe, Cu, Zn and Cu/Zn in the SCA pathogenesis process. (author)

  12. Evaluation of Fe and Zn/Cu ratio in serum of patients with sickle cell anemia by total reflection X-ray fluorescence using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Canellas, Catarine G.L.; Leitao, Roberta G.; Lopes, Ricardo T., E-mail: catarine@lin.ufrj.b, E-mail: ricardo@lin.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Engenharia Nuclear. Lab. de Instrumentaco Nuclear; Carvalho, Silvia M.F., E-mail: silvia@hemorio.rj.gov.b [State Institute of Hematology Arthur de Siqueira Cavalcanti (HEMORIO), Rio de Janeiro, RJ (Brazil); Bellido, Alfredo Victor B., E-mail: alfredo@ien.gov.b [Federal Fluminense University (UFF), Niteroi, RJ (Brazil). Chemistry Inst.; Anjos, Marcelino J., E-mail: marcelin@lin.ufrj.b [State University of Rio de Janeiro (UERJ), RJ (Brazil). Physics Inst.

    2011-07-01

    Sickle cell anemia (SCA) is a blood disorder that affects hemoglobin, the protein found in red blood cells that help carry oxygen throughout the body. In this work we have analyzed serum samples from patients with SCA by using total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). The SRTXRF measurements were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo using a polychromatic beam. We have studied forty-three patients aged 18-50 years old, suffering from SCA and Sixty healthy volunteers aged 18-60 years old. It was possible to determine the concentrations of the following elements: P, S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. Student's t-test was applied in order to check whether the two populations (CG x SCA) had the same mean values. It was observed that elemental concentration of P, Cl, K, Fe, Cu, Zn and Br differed significantly ({alpha} = 0.05) between groups of healthy subjects and SCA. The concentrations of K, Fe and Cu in the serum samples of patients with SCA were larger 15%, 120 % and 20 %, respectively, when compared with the CG. On the other hand, the concentrations of P (-20 %), Cl (-6 %), Zn (-25 %) and Br (-22 %) were smaller than the values determined for the control group. The serum level Cu/Zn ratio was significantly higher (60%) in the serum samples of patients with SCA group than the CG. So, the Cu/Zn ratio can be used as an adjuvant index in enhancement for diagnosis of SCA. There are evidences of an association among Fe, Cu, Zn and Cu/Zn in the SCA pathogenesis process. (author)

  13. Evaluation of Fe and Zn/Cu ratio in serum of patients with sickle cell anemia by total reflection X-ray fluorescence using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Canellas, Catarine G.L.; Leitao, Roberta G; Lopes, Ricardo T., E-mail: catarine@lin.ufrj.b, E-mail: ricardo@lin.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Engenharia Nuclear. Lab. de Instrumentaco Nuclear; Carvalho, Silvia M.F., E-mail: silvia@hemorio.rj.gov.b [State Institute of Hematology Arthur de Siqueira Cavalcanti (HEMORIO), Rio de Janeiro, RJ (Brazil); Bellido, Alfredo Victor B., E-mail: alfredo@ien.gov.b [Federal Fluminense University (UFF), Niteroi, RJ (Brazil). Chemistry Inst.; Anjos, Marcelino J., E-mail: marcelin@lin.ufrj.b [State University of Rio de Janeiro (UERJ), RJ (Brazil). Physics Inst.

    2011-07-01

    Sickle cell anemia (SCA) is a blood disorder that affects hemoglobin, the protein found in red blood cells that help carry oxygen throughout the body. In this work we have analyzed serum samples from patients with SCA by using total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). The SRTXRF measurements were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo using a polychromatic beam. We have studied forty-three patients aged 18-50 years old, suffering from SCA and Sixty healthy volunteers aged 18-60 years old. It was possible to determine the concentrations of the following elements: P, S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. Student's t-test was applied in order to check whether the two populations (CG x SCA) had the same mean values. It was observed that elemental concentration of P, Cl, K, Fe, Cu, Zn and Br differed significantly ({alpha} = 0.05) between groups of healthy subjects and SCA. The concentrations of K, Fe and Cu in the serum samples of patients with SCA were larger 15%, 120 % and 20 %, respectively, when compared with the CG. On the other hand, the concentrations of P (-20 %), Cl (-6 %), Zn (-25 %) and Br (-22 %) were smaller than the values determined for the control group. The serum level Cu/Zn ratio was significantly higher (60%) in the serum samples of patients with SCA group than the CG. So, the Cu/Zn ratio can be used as an adjuvant index in enhancement for diagnosis of SCA. There are evidences of an association among Fe, Cu, Zn and Cu/Zn in the SCA pathogenesis process. (author)

  14. Parameter study of self-absorption effects in Total Reflection X-ray Fluorescence-X-ray Absorption Near Edge Structure analysis of arsenic

    International Nuclear Information System (INIS)

    Meirer, F.; Pepponi, G.; Streli, C.; Wobrauschek, P.; Kregsamer, P.; Zoeger, N.; Falkenberg, G.

    2008-01-01

    Total reflection X-ray Fluorescence (TXRF) analysis in combination with X-ray Absorption Near Edge Structure (XANES) analysis is a powerful method to perform chemical speciation studies at trace element levels. However, when measuring samples with higher concentrations and in particular standards, damping of the oscillations is observed. In this study the influence of self-absorption effects on TXRF-XANES measurements was investigated by comparing measurements with theoretical calculations. As(V) standard solutions were prepared at various concentrations and dried on flat substrates. The measurements showed a correlation between the damping of the oscillations and the As mass deposited. A Monte-Carlo simulation was developed using data of the samples shapes obtained from confocal white light microscopy. The results showed good agreement with the measurements; they confirmed that the key parameters are the density of the investigated atom in the dried residues and the shape of the residue, parameters that combined define the total mass crossed by a certain portion of the incident beam. The study presents a simple approach for an a priori evaluation of the self-absorption in TXRF X-ray absorption studies. The consequences for Extended X-ray Absorption Fine Structure (EXAFS) and XANES measurements under grazing incidence conditions are discussed, leading to the conclusion that the damping of the oscillations seems to make EXAFS of concentrated samples non feasible. For XANES 'fingerprint' analysis samples should be prepared with a deposited mass and sample shape leading to an acceptable absorption for the actual investigation

  15. Seasonal determination of trace and ultra-trace content in Macrocystis pyrifera from San Jorge Gulf (Patagonia) by Total Reflection X-ray Fluorescence

    Science.gov (United States)

    Salomone, Vanesa N.; Riera, Marina; Cerchietti, Luciana; Custo, Graciela; Muniain, Claudia

    2017-05-01

    Seaweed have a great capacity to accumulate heavy metals in their tissues. The chemical characterization of seaweed is important due to their use in environmental monitoring and human or animal food. The aim of the present study was to evaluate the multi-elemental composition of seaweed from San Jorge Gulf (Patagonia, Argentina) by Total Reflection X-ray Fluorescence (TXRF). The elements As, Br, Cu, Cr, Fe, Mn, Ni, Pb, Rb, Sr, V and Zn were seasonally analyzed and quantified in blades of Macrocystis pyrifera. TXRF showed to be a suitable technique for simultaneous multi-element analysis in this kind of samples. The results revealed seasonal variations in the chemical content for some elements; arsenic content was maximum in summer and autumn, iron concentration increased to the winter and zinc concentration was maximum in autumn. The sum of principal micronutrients (Fe + Zn + Mn + Cu) varied between 114 and 171 mg k- 1 g dw. The total As concentration ranged between 36 and 66 mg kg- 1. Lead, nickel and copper were not detected.

  16. The potential for portable X-ray fluorescence determination of soil copper at ancient metallurgy sites, and considerations beyond measurements of total concentrations.

    Science.gov (United States)

    Tighe, M; Rogan, G; Wilson, S C; Grave, P; Kealhofer, L; Yukongdi, P

    2018-01-15

    Copper (Cu) at ancient metallurgy sites represents the earliest instance of anthropogenically generated metal pollution. Such sites are spread across a wide range of environments from Eurasia to South America, and provide a unique opportunity to investigate the past and present extent and impact of metalworking contamination. Establishing the concentration and extent of soil Cu at archaeometallurgy sites can enhance archaeological interpretations of site use but can also, more fundamentally, provide an initial indication of contamination risk from such sites. Systematic evaluations of total soil Cu concentrations at ancient metalworking sites have not been conducted, due in part to the limitations of conventional laboratory-based protocols. In this paper, we first review what is known about Cu soil concentrations at ancient metallurgy sites. We then assess the benefits and challenges of portable X-ray fluorescence spectrometry (pXRF) as an alternative, rapid technique for the assessment of background and contaminant levels of Cu in soils. We conclude that pXRF is an effective tool for identifying potential contamination. Finally, we provide an overview of some major considerations beyond total Cu concentrations, such as bioavailability assessments, that will need to be considered at such sites to move toward a complete assessment of environmental and human risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Monitoring of the environmental pollution by trace element analysis in tree-rings using synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Sirito de Vives, Ana Elisa [School of Civil Engineering, Architecture and Urban Design Methodist University of Piracicaba, Rodovia Santa Barbara D' Oeste/Iracemapolis, km 01, 13450-000 Santa Barbara D' Oeste, SP (Brazil)]. E-mail: aesvives@unimep.br; Moreira, Silvana [State University of Campinas - UNICAMP/FEC (Brazil); Brienza, Sandra Maria Boscolo [School of Civil Engineering, Architecture and Urban Design Methodist University of Piracicaba, Rodovia Santa Barbara D' Oeste/Iracemapolis, km 01, 13450-000 Santa Barbara D' Oeste, SP (Brazil); Silva Medeiros, Jean Gabriel [University of Sao Paulo - USP/ ESALQ (Brazil); Tomazello Filho, Mario Tomazello [University of Sao Paulo - USP/ ESALQ (Brazil); Araujo Domingues Zucchi, Orgheda Luiza [University of Sao Paulo - USP/FCFRP (Brazil); Nascimento Filho, Virgilio Franco do [University of Sao Paulo - USP/CENA (Brazil)

    2006-11-15

    This paper aims to study the environmental pollution in the tree development, in order to evaluate its use as bioindicator in urban and country sides. The sample collection was carried out in Piracicaba city, Sao Paulo State, which presents high level of environmental contamination in water, soil and air, due to industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. The species Caesalpinia peltophoroides ('Sibipiruna') was selected because it is widely used in urban forestation. Synchrotron Radiation Total Reflection X-ray Fluorescence technique (SR-TXRF) was employed to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was performed in the Brazilian Synchrotron Light Source Laboratory, using a white beam for excitation and a Si(Li) detector for X-ray detection. In several samples, P, K, Ca, Ti, Fe, Sr, Ba and Pb were quantified. The K/Ca, K/P and Pb/Ca ratios were found to decrease towards the bark.

  18. Biofilms as bio-indicator for polluted waters? Total reflection X-ray fluorescence analysis of biofilms of the Tisza river (Hungary)

    Energy Technology Data Exchange (ETDEWEB)

    Mages, Margarete; Ovari, Mihaly; Tuempling, Wolf v. [Department of Inland Water Research Magdeburg, UFZ Centre for Environmental Research Leipzig-Halle, Brueckstrasse 3a, 39114, Magdeburg (Germany); Kroepfl, Krisztina [Department of Chemical Technology and Environmental Chemistry, Eoetvoes University, Pazmany Peter setany 1/A, 1117, Budapest (Hungary)

    2004-02-01

    The aim of this work was to investigate the heavy metal accumulation by natural biofilms living in the catchment area of the Tisza river in Hungary, as well as in biofilms cultivated in vitro. Laboratory tests have demonstrated that metals can be adsorbed on biofilms, depending on their concentration and on the availability of free sorptive places. Biofilms were cultivated in vitro in natural freshwater from the Saale river, Germany. After reaching the plateau phase, Cu was added to reach a concentration of 100 {mu}g/L. An increase of its mass fraction in the biofilm was observed, which caused the decrease of the concentration in the water phase. Unfortunately, the reactor wall was also found to act as adsorbent for Cu. More detailed results of our in vitro experiments will be published in a forthcoming paper. Naturally grown biofilm samples from exposed as well as background places at the Hungarian rivers Szamos and Tisza were collected in 2000 and 2002 after the cyanide spill, and analysed using total reflection X-ray fluorescence analysis (TXRF). Metal mass fraction differences as high as two orders of magnitude were found between polluted and unpolluted (background) sampling points. Extremely high concentration values, e.g. 5600 {mu}g/g Zn in biofilm, were found at highly polluted sampling points. This means an enrichment factor of ca. 10,000 compared to the water phase. (orig.)

  19. Total reflection X-ray fluorescence measurements of S and P in proteins using a vacuum chamber specially designed for low Z elements

    International Nuclear Information System (INIS)

    Rauwolf, M.; Vanhoof, C.; Tirez, K.; Maes, E.; Ingerle, D.; Wobrauschek, P.; Streli, C.

    2014-01-01

    As the ratio of phosphorus and sulfur in proteins allows the determination of the phosphorylation degree in proteins, the absolute determination of phosphorus and sulfur in organic samples is of growing interest. While it takes some effort to quantify phosphorus and sulfur with inductively coupled quadrupole plasma mass spectrometry (ICP-QMS), total reflection X-ray fluorescence analysis (TXRF) allows easy quantification. In the presented work, the low Z TXRF spectrometer at the Atominstitut was used to analyze phosphorus and sulfur in proteins. Although the preparation of the protein samples proved to be more difficult than originally expected, it could be shown that TXRF is well suited for the determination of P and S in proteins. The obtained lower limits of detection (LLD) for P and S in proteins were extrapolated for 1000s and were 34 pg and 19 pg, respectively. The importance of height scans for each sample to exclude heterogeneities was demonstrated. - Highlights: • Low Z TXRF spectrometry was used to analyze phosphorus and sulfur in proteins. • TXRF is well suited for the determination of P and S in proteins. • Good detection limits for P (34 pg) and S (19 pg) were achieved. • Due to the detection limits, we propose that TXRF is a suitable method to analyze protein fractions

  20. Effect of modulation of the particle size distributions in the direct solid analysis by total-reflection X-ray fluorescence

    Science.gov (United States)

    Fernández-Ruiz, Ramón; Friedrich K., E. Josue; Redrejo, M. J.

    2018-02-01

    The main goal of this work was to investigate, in a systematic way, the influence of the controlled modulation of the particle size distribution of a representative solid sample with respect to the more relevant analytical parameters of the Direct Solid Analysis (DSA) by Total-reflection X-Ray Fluorescence (TXRF) quantitative method. In particular, accuracy, uncertainty, linearity and detection limits were correlated with the main parameters of their size distributions for the following elements; Al, Si, P, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb. In all cases strong correlations were finded. The main conclusion of this work can be resumed as follows; the modulation of particles shape to lower average sizes next to a minimization of the width of particle size distributions, produce a strong increment of accuracy, minimization of uncertainties and limit of detections for DSA-TXRF methodology. These achievements allow the future use of the DSA-TXRF analytical methodology for development of ISO norms and standardized protocols for the direct analysis of solids by mean of TXRF.

  1. Multielement analysis of environmental samples by total-reflection X-ray fluorescence sprectrometry, neutron activation analysis and inductively coupled plasma optical emission spectroscopy

    International Nuclear Information System (INIS)

    Michaelis, W.

    1986-01-01

    In environmental research and protection trace elements have to be determined over a wide range of atomic number, down to very low concentrations, and in quite different matrices. This challenge requires the availability of complementary analytical methods characterized by a high detection power and few sources of systematic errors. Besides, the capacity of multielement detection is often desired since it facilitates the talking of many problems in which numerous trace elements are of direct concern. Total-reflection X-ray fluorescence, neutron activation analysis and inductively coupled plasma optical emission spectroscopy, in principle fulfill these requirements quite well. However, each method has its domain, and the application to certain sample species may be less promising. Under this aspect, the paper summarizes some recent developments and investigations, including intercomparisons as far as possible. Various matrices are considered : rainwater and airborne particulates, soil samples, river sediments and suspended particulate matter, river water filtrates, ozean water, and organic matrices. Capabilities and limitations are discussed. Sample preparation techniques are described if they are new or essential for achieving the results given. (orig.) [de

  2. Quantification of potentially toxic elements in sewage and sludge from treatment plants in the cities of Campinas and Jaguariuna using synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luciana Carla Ferreira de; Canteras, Felippe Benavente; Moreira, Silvana, E-mail: silvana@fec.unicamp.br, E-mail: felippe.canteras@gmail.com, E-mail: lucarla24@gmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Inst. Politecnico. Dept. de Saneamento e Ambiente

    2013-07-01

    The rapid urban and industrial development in last decades has brought as one of the consequences, changes in the environment. The lack of planning of city growth is, today, one of the major causes of water pollution including residential, industrial, agricultural, and hospital waste. The metals contamination is a major problem, causing serious changes to the environment, causing harm to human health. The sludge generated at sewage treatment plants, is an important source of nutrients and organic matter, and therefore it can also be reused mainly for agricultural use, since contaminants are removed. The cities of Campinas and Jaguariuna are inserted in the Campinas Metropolitan Region (CMR), one of the most dynamic regions in the Brazilian economy. Therefore, to study the anthropogenic influences of the cities, evaluated the quality of raw and treated effluent and the sludge generated in sewage treatment plants, especially with regard to heavy metals. Measurements of metals were performed by Synchrotron Radiation Total Reflection X-ray Fluorescence. For treated effluent data were compared to CONAMA 357 law and Cr, Mn, Fe, Ni, Cu, Zn, Ba and Pb showed concentrations in according with the law. To reuse in agriculture the contents were compared to the limits defined by CETESB and some elements had concentrations above to the permitted preventing its reuse. For sludge, Cr, Ni, Cu, Zn, Ba and Pb, in the two treatment plants studied, the concentrations were lower than the maximum permissible values established by CONAMA 375 law allowing the sludge application sludge on agricultural land. (author)

  3. Mineral elements and essential trace elements in blood of seals of the North Sea measured by total-reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Griesel, S.; Mundry, R.; Kakuschke, A.; Fonfara, S.; Siebert, U.; Prange, A.

    2006-01-01

    Mineral and essential trace elements are involved in numerous physiological processes in mammals. Often, diseases are associated with an imbalance of the electrolyte homeostasis. In this study, the concentrations of mineral elements (P, S, K, Ca) and essential trace elements (Fe, Cu, Zn, Se, Rb, Sr) in whole blood of harbor seals (Phoca vitulina) were determined using total-reflection X-ray fluorescence spectrometry (TXRF). Samples from 81 free-ranging harbor seals from the North Sea and two captive seals were collected during 2003-2005. Reference ranges and element correlations for health status determination were derived for P, S, K, Ca, Fe, Cu, and Zn level in whole blood. Grouping the seals by age, gender and sample location the concentration levels of the elements were compared. The blood from two captive seals with signs of diseases and four free-ranging seals showed reduced element levels of P, S, and Ca and differences in element correlation of electrolytes were ascertained. Thus, simultaneous measurements of several elements in only 500 μL volumes of whole blood provide the possibility to obtain information on both, the electrolyte balance and the hydration status of the seals. The method could therefore serve as an additional biomonitoring tool for the health assessment

  4. Determination of calcium, potassium, manganese, iron, copper and zinc levels in representative samples of two onion cultivars using total reflection X-ray fluorescence and ultrasound extraction procedure

    International Nuclear Information System (INIS)

    Alvarez, J.; Marco, L.M.; Arroyo, J.; Greaves, E.D.; Rivas, R.

    2003-01-01

    The chemical characterization of onion cultivar samples is an important tool for the enhancement of their productivity due to the fact that chemical composition is closed related to the quality of the products. A new sample preparation procedure for elemental characterization is proposed, involving the acid extraction of the analytes from crude samples by means of an ultrasonic bath, avoiding the required digestion of samples in vegetable tissue analysis. The technique of total reflection X-ray fluorescence (TXRF) was successfully applied for the simultaneous determination of the elements Ca, K, Mn, Fe, Cu and Zn. The procedure was compared with the wet ashing and dry ashing procedures for all the elements using multivariate analysis and the Scheffe test. The technique of flame atomic absorption spectrometry (FAAS) was employed for comparison purposes and accuracy evaluation of the proposed analysis method. A good agreement between the two techniques was found when using the dry ashing and ultrasound leaching procedures. The levels of each element found for representative samples of two onion cultivars (Yellow Granex PRR 502 and 438 Granex) were also compared by the same method. Levels of K, Mn and Zn were significantly higher in the 438 Granex cultivar, while levels of Ca, Fe and Cu were significantly higher in the Yellow Granex PRR 502 cultivar

  5. Monitoring of the environmental pollution by trace element analysis in tree-rings using synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Sirito de Vives, Ana Elisa; Moreira, Silvana; Brienza, Sandra Maria Boscolo; Silva Medeiros, Jean Gabriel; Tomazello Filho, Mario Tomazello; Araujo Domingues Zucchi, Orgheda Luiza; Nascimento Filho, Virgilio Franco do

    2006-01-01

    This paper aims to study the environmental pollution in the tree development, in order to evaluate its use as bioindicator in urban and country sides. The sample collection was carried out in Piracicaba city, Sao Paulo State, which presents high level of environmental contamination in water, soil and air, due to industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. The species Caesalpinia peltophoroides ('Sibipiruna') was selected because it is widely used in urban forestation. Synchrotron Radiation Total Reflection X-ray Fluorescence technique (SR-TXRF) was employed to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was performed in the Brazilian Synchrotron Light Source Laboratory, using a white beam for excitation and a Si(Li) detector for X-ray detection. In several samples, P, K, Ca, Ti, Fe, Sr, Ba and Pb were quantified. The K/Ca, K/P and Pb/Ca ratios were found to decrease towards the bark

  6. Analysis of some chosen elements of cerebrospinal fluid and serum in amyotrophic lateral sclerosis patients by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Ostachowicz, B.; Lankosz, M.; Tomik, B.; Adamek, D.; Wobrauschek, P.; Streli, C.; Kregsamer, P.

    2006-01-01

    Trace elements play an important role in the human central nervous system. Significant variations of the concentration of trace elements in body fluids may occur in neurodegenerative diseases. In the present work an investigation of the elemental composition of the serum, and the cerebrospinal fluid in amyotrophic lateral sclerosis patients and a control group was performed. For the analysis of the body fluids Total reflection X-ray Fluorescence (TXRF) spectrometry was used. The samples were taken during routine diagnostic procedures. Na, Mg, Cl, K, Ca, Cu, Zn, and Br were determined in both fluids. In order to validate the results of analysis a serum standard reference material was measured. A t-test was applied to check if the mean concentrations of the elements are different for ALS and the control group. For the serum samples higher values for Br were found in the ALS group, for the cerebrospinal fluid lower values of Na, Mg and Zn as well as higher Ca values were found in the ALS group compared to the control group

  7. Analysis of some chosen elements of cerebrospinal fluid and serum in amyotrophic lateral sclerosis patients by total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Ostachowicz, B. [Department of Radiometric Analyses, Faculty of Physic and Applied Computer Science, AGH, University of Science and Technology, Cracow (Poland); Lankosz, M. [Department of Radiometric Analyses, Faculty of Physic and Applied Computer Science, AGH, University of Science and Technology, Cracow (Poland); Tomik, B. [Institute of Neurology, Collegium Medicum, Jagiellonian University, Cracow (Poland); Adamek, D. [Institute of Neurology, Collegium Medicum, Jagiellonian University, Cracow (Poland); Wobrauschek, P. [Atominstitut, Vienna University of Technology, Vienna (Austria); Streli, C. [Atominstitut, Vienna University of Technology, Vienna (Austria)]. E-mail: streli@ati.ac.at; Kregsamer, P. [Atominstitut, Vienna University of Technology, Vienna (Austria)

    2006-11-15

    Trace elements play an important role in the human central nervous system. Significant variations of the concentration of trace elements in body fluids may occur in neurodegenerative diseases. In the present work an investigation of the elemental composition of the serum, and the cerebrospinal fluid in amyotrophic lateral sclerosis patients and a control group was performed. For the analysis of the body fluids Total reflection X-ray Fluorescence (TXRF) spectrometry was used. The samples were taken during routine diagnostic procedures. Na, Mg, Cl, K, Ca, Cu, Zn, and Br were determined in both fluids. In order to validate the results of analysis a serum standard reference material was measured. A t-test was applied to check if the mean concentrations of the elements are different for ALS and the control group. For the serum samples higher values for Br were found in the ALS group, for the cerebrospinal fluid lower values of Na, Mg and Zn as well as higher Ca values were found in the ALS group compared to the control group.

  8. Characterization by Total Reflection X-ray Fluorescence Spectrometry of filtered water into the cave under the Sun Pyramid in Teotihuacan City

    International Nuclear Information System (INIS)

    Martinez, T.; Zarazua, G.; Avila-Perez, P.; Juarez, F.; Cabrera, L.; Martinez, G.

    2008-01-01

    Teotihuacan (50 km north-east Mexico City) was the most important ancient city in Mesoamerica and it flourished 200-750 AC. It is situated in the central part of the Valley of Teotihuacan, in Central Mexico. This study was carried out in the 102 m-long cave under the largest single construction, the massive Sun Pyramid, being located on the east side of the 'Avenue of the Dead', in the northern half-part of the city. The study shows the results of Total Reflection X-ray Fluorescence Spectrometry analysis and other techniques of a water sample obtained from the inside of the cave. The inside temperature ranged between 19 and 22 deg. C; relative humidity was between 98 and 99.3%; water-dropping velocity (water de-sorption capability) was 13.5 μL min -1 . Water samples from wells around the site were analyzed too. Metal concentration in all of the water samples matches the characteristics of the sampling site, well's depth, soil and minerals

  9. Analysis of heavy metals and minerals elements in the turmeric using Total-Reflection X-ray Fluorescence analysis technique and Atomic Absorption Spectrometry

    International Nuclear Information System (INIS)

    Andriamisetra, V.M.Z.

    2014-01-01

    Currently, many studies demonstrate anti-cancer and anti-inflammatory benefits of turmeric. The aims of this work is to perform analysis of metals such as calcium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, bromine, rubidium, strontium, cadmium and lead in the turmeric collected from various places in Madagascar. The analysis by total reflection X-ray fluorescence technique is used to determine the concentrations of heavy metals, while the atomic absorption spectrometry is used for the determination of trace elements. Analysis results show that the concentration of calcium in the turmeric is very high, its average concentration is 1025.8 mg.kg -1 . The average concentrations of manganese, of copper and of iron are respectively 44.7 mg.kg -1 ; 19.7 mg.kg -1 and 53.6 mg.kg -1 . The average concentrations of zinc, of rubidium and of strontium are respectively 17.3 mg.kg -1 ; 35.2 mg.kg -1 and 21.7 mg.kg -1 [fr

  10. Characterization by Total Reflection X-ray Fluorescence Spectrometry of filtered water into the cave under the Sun Pyramid in Teotihuacan City

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, T. [National University of Mexico, Faculty of Chemistry, Building D, CU, O4510, Mexico, D.F. (Mexico)], E-mail: tmc@servidor.unam.mx; Zarazua, G.; Avila-Perez, P. [National Institute of Nuclear Research, Carr. Mexico-Toluca Km 36.5, 52045, Salazar, Ocoyoacac, Edo. de Mexico (Mexico); Juarez, F. [National University of Mexico, Institute of Geophysics, Circuito Institutos, CU, 04510 Mexico, D.F. (Mexico); Cabrera, L. [National University of Mexico, Faculty of Chemistry, Building D, CU, O4510, Mexico, D.F. (Mexico); Martinez, G. [Coordinacion Nacional de Conservacion del Patrimonio Cultural, Xicotencatl y General Anaya s/n., 04120, Mexico, D.F. (Mexico)

    2008-12-15

    Teotihuacan (50 km north-east Mexico City) was the most important ancient city in Mesoamerica and it flourished 200-750 AC. It is situated in the central part of the Valley of Teotihuacan, in Central Mexico. This study was carried out in the 102 m-long cave under the largest single construction, the massive Sun Pyramid, being located on the east side of the 'Avenue of the Dead', in the northern half-part of the city. The study shows the results of Total Reflection X-ray Fluorescence Spectrometry analysis and other techniques of a water sample obtained from the inside of the cave. The inside temperature ranged between 19 and 22 deg. C; relative humidity was between 98 and 99.3%; water-dropping velocity (water de-sorption capability) was 13.5 {mu}L min{sup -1}. Water samples from wells around the site were analyzed too. Metal concentration in all of the water samples matches the characteristics of the sampling site, well's depth, soil and minerals.

  11. Quantification of potentially toxic elements in sewage and sludge from treatment plants in the cities of Campinas and Jaguariuna using synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Souza, Luciana Carla Ferreira de; Canteras, Felippe Benavente; Moreira, Silvana

    2013-01-01

    The rapid urban and industrial development in last decades has brought as one of the consequences, changes in the environment. The lack of planning of city growth is, today, one of the major causes of water pollution including residential, industrial, agricultural, and hospital waste. The metals contamination is a major problem, causing serious changes to the environment, causing harm to human health. The sludge generated at sewage treatment plants, is an important source of nutrients and organic matter, and therefore it can also be reused mainly for agricultural use, since contaminants are removed. The cities of Campinas and Jaguariuna are inserted in the Campinas Metropolitan Region (CMR), one of the most dynamic regions in the Brazilian economy. Therefore, to study the anthropogenic influences of the cities, evaluated the quality of raw and treated effluent and the sludge generated in sewage treatment plants, especially with regard to heavy metals. Measurements of metals were performed by Synchrotron Radiation Total Reflection X-ray Fluorescence. For treated effluent data were compared to CONAMA 357 law and Cr, Mn, Fe, Ni, Cu, Zn, Ba and Pb showed concentrations in according with the law. To reuse in agriculture the contents were compared to the limits defined by CETESB and some elements had concentrations above to the permitted preventing its reuse. For sludge, Cr, Ni, Cu, Zn, Ba and Pb, in the two treatment plants studied, the concentrations were lower than the maximum permissible values established by CONAMA 375 law allowing the sludge application sludge on agricultural land. (author)

  12. Biomonitoring of environmental pollution using growth tree rings of Tipuana tipu: Quantification by synchrotron radiation total reflection X-ray fluorescence

    Science.gov (United States)

    Geraldo, S. M.; Canteras, F. B.; Moreira, S.

    2014-02-01

    Currently, many studies use the bioindicators to qualitatively and/or quantitatively measure pollution. The analyses of tree growth rings represent one such bioindicator as changes in the environment are often recorded as impressions in the wood. The main objective of the present study is to examine the growth rings of Tipuana tipu - a member of the Leguminosae family that is native to Argentina and Bolivia and was introduced in Brazil as an ornamental plant - for potentially toxic elements. T. tipu is one of the most common trees in the urban landscape of Sao Paulo city and would provide an accurate reflection of environment changes. Tree ring samples previously dated using Synchrotron Radiation Total Reflection X-ray Fluorescence were collected from strategic locations in Sao Paulo. These locations include Piracicaba (SP) that has little access and small flow traffic and the campus of the University of São Paulo. Some trace elements present concentrations higher than considered as normal in some periods. In São Paulo city, samples collected from the campus of University of São Paulo (Butantã), showed the highest toxicity, with concentrations above the tolerable limit for the elements: Cr, Cu, and Pb. For the samples collected in Piracicaba city, one sample presented highest concentrations for the majority of the elements when compared to the other four samples collected at the same place, exceeding the toxicity limits for: Cr, Ni, Cu, and Pb.

  13. Dielectric compound parabolic concentrating solar collector with frustrated total internal reflection absorber

    Science.gov (United States)

    Hull, J. R.

    Since its introduction, the concept of nonimaging solar concentrators, as exemplified by the compound parabolic concentrator (CPC) design, has greatly enhanced the ability to collect solar energy efficiently in thermal and photovoltaic devices. When used as a primary concentrator, a CPC can provide significant concentration without the complication of a tracking mechanism and its associated maintenance problems. When used as a secondary, a CPC provides higher total concentration, or for a fixed concentration, tolerates greater tracking error in the primary.

  14. URGENSI PENILAIAN LINGKUNGAN INTERNAL DAN EKSTERNAL DALAM PENERAPAN TOTAL QUALITY MANAGEMENT (TQM DI LEMBAGA PENDIDIKAN ISLAM

    Directory of Open Access Journals (Sweden)

    Adri Eferi

    2016-11-01

    This article aims to explain the urgency of the internal and external environment assessment in the application of TQM. From the authors conclude that the study can be distinguished on the Environment organization's internal environment which comprises three supporting elements: first, the structure, with regard to communication, authority and work flows. The structure is often also called the chain of command, and depicted graphically using organization charts; secondly, culture, a pattern of beliefs, expectations, and values that prevail among members of the organization; and third, the resource, include the individual's expertise, capabilities, and managerial talents of every member of the organization. While the external environment is the conditions that are outside the organization, which also directly influences the survival of organizations. As in assessing both the environment, can be done by using the characteristics that exist in TQM, namely: a focus on the customer; b obsession with quality; c a scientific approach; d long-term commitment; e team work; f improvement of the system on an ongoing basis; g education and training; h freedom of hand; i unity of purpose; and j the involvement and empowerment of employees.

  15. Physicochemical characteristics, total phenols and pigments of national and international honeys in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Abdulaziz S. Alqarni

    2016-01-01

    Full Text Available In 23 types of honey from Saudi Arabia and six other countries, the levels of some minor components and floral pigments as well as physicochemical characteristics were investigated. Most tested Saudi honeys, e.g. Acacia and Seder showed high values of density and total soluble solids and low water content compared to exotic ones. Some Acacia and Manuka samples had higher HMF contents than permitted levels. All the tested honeys were acidic; however Acacia honey had total acidity values over those of permitted levels, while most of the remainding types were comparable or acceptable. Also, Saudi Acacia and Egyptian honeys contained more content of total nitrogen, free amino acids and proline than those of the other tested types. Dark-colored honeys e.g. Acacia contained more phenolic content than those of the light-colored ones. Carotenoids were the predominant floral pigments in all the tested honeys, while xanthophylls and anthocyanins were the least predominant ones. Seder honeys showed moderate values of the tested characteristics compared to other types. The tested parameters are useful to determine the botanical origin of Saudi or exotic honeys and their quality. Further research on specific physicochemical properties of Saudi Acacia honey especially acidity is very much recommended. New criteria based on the regional characteristics of Saudi honeys including antioxidants, micro-constituents are suggested.

  16. Measurement of the internal pH of mast cell granules using microvolumetric fluorescence and isotopic techniques

    International Nuclear Information System (INIS)

    De Young, M.B.; Nemeth, E.F.; Scarpa, A.

    1987-01-01

    The intragranular pH of isolated mast cell granules was measured. Because of the minute amounts of isolated granules available, two techniques were developed by modifying aminoacridine fluorescence and [ 14 C]methylamine accumulation techniques to permit measurements with microliter sample volumes. Granule purity was demonstrated by electron microscopy, ruthenium red exclusion, and biochemical (histamine, mast cell granule protease) analysis. The internal pH was determined to be 5.55 +/- 0.06, indicating that the pH environment within mast cell granules is not significantly different from that of previously studied granule types (i.e., chromaffin, platelet, pancreatic islet, and pituitary granules). Collapse of the pH gradient by NH+4 was demonstrated with both techniques. No evidence of Cl-/OH- or specific cation/H+ transport was found, and major chloride permeability could not be unequivocably demonstrated. Ca 2+ and Cl- at concentrations normally present extracellularly destabilized granules in the presence of NH+4, but this phenomenon does not necessarily indicate a role for these ions in the exocytotic release of granule contents from intact cells. The pH measurement techniques developed for investigating the properties of granules in mast cells may be useful for studying other granules that can be obtained only in limited quantities

  17. Use of high-intensity sonication for pre-treatment of biological tissues prior to multielemental analysis by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    De La Calle, Inmaculada; Costas, Marta; Cabaleiro, Noelia; Lavilla, Isela; Bendicho, Carlos

    2012-01-01

    In this work, two ultrasound-based procedures are developed for sample preparation prior to determination of P, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, As, Se and Sr in biological tissues by total reflection X-ray fluorescence spectrometry. Ultrasound-assisted extraction by means of a cup-horn sonoreactor and ultrasonic-probe slurry sampling were compared with a well-established procedure such as magnetic agitation slurry sampling. For that purpose, seven certified reference materials and different real samples of animal tissue were used. Similar accuracy and precision is obtained with the three sample preparation approaches tried. Limits of detection were dependent on both the sample matrix and the sample pre-treatment used, best values being achieved with ultrasound-assisted extraction. Advantages of ultrasound-assisted extraction include reduced sample handling, decreased contamination risks (neither addition of surfactants nor use of foreign objects inside the extraction vial), simpler background (no solid particles onto the sample carrier) and improved recovery for some elements such as P. A mixture of 10% v/v HNO 3 + 20–40% v/v HCl was suitable for extraction from biological tissues. - Highlights: ► We implement high-intensity sonication for pre-treatment of biological tissues. ► Multielemental analysis is performed by total reflection X-ray spectrometry. ► Ultrasound-based procedures are developed and compared to conventional slurry preparation. ► Features such as background, recovery and sample handling are favored by using ultrasonic extraction.

  18. 2002 results: TotalFinaElf makes a ''much better performance'' than the overall international oil groups

    International Nuclear Information System (INIS)

    Salles, E.

    2003-01-01

    T. Desmarest, head of TotalFinaElf oil and gas company, has presented the 2002 results of his company in the particular context of a moving international oil situation (the Iraq crisis and the situation in Venezuela) with important consequences on markets. At the same time, the company decided to change its name into 'Total' and to adopt a new logo. The results show a 17% drop with respect to 2001 but a 10% increase of the production. The high rate of exploration successes has led to the discovery of about 1 billion of bpe with a 0.8 US$ cost per bpe, which represents the best performance of the 5 world oil majors. The rate of reserves renewal reached 151% (11.2 billions of bpe at the end of 2002). The downstream activities (refining/distribution and basic chemistry) encountered much more problems for various reasons: low economic growth, climate warmth, international instability etc.. (J.S.)

  19. Status and trends in the development of Total Productive Maintenance (TPM) - a review of international articles

    DEFF Research Database (Denmark)

    Andreassen, Mads; Gertsen, Frank; Christiansen, Thomas Bøhm

    2004-01-01

    Corporate continuous innovation efforts are often guided by (more or less) customized standard management concepts such as "TQM", "BPR" or "Lean". The focus of this article, Total Productive Maintenance (TPM), is a contemporary example of such a concept. Although the concept first appeared more...... maintenance and high efficiency of the production facilities. However, during the last ten years, the concepthas been developed into a company wide (management)concept, also compromising efficiency in the administrative part of a company, safety and environmental aspects, as well as product quality. Based...

  20. Effect of surface plasmon polaritons on the sensitivity of refractive index measurement using total internal reflection method

    International Nuclear Information System (INIS)

    Roshan Entezar, S.

    2015-01-01

    The phase difference between two p-polarized and s-polarized plane waves which are reflected under total internal reflection from the base of a prism with a thin metal coating is studied. Typically such a quantity can be used to measure the refractive index of a test material using the total internal reflection method. It is shown that due to the excitation of surface plasmon polaritons at the interface between the tested dielectric material and the thin metal layer, the p-polarized light experiences a large phase shift which enlarges the phase difference between the p-polarized and the s-polarized waves. As a result, the sensitivity of refractive index measurement increases and the error in determining the refractive index decreases. - Highlights: • Phase difference of totally internally reflected p and s polarized beams is studied. • Excitation of the surface wave increases the phase shift of the p-polarized light. • The sensitivity of refractive index measurement increases by using a coated prism. • The error in determining the refractive index decreases using the coated prism

  1. Blood volume, blood pressure and total body sodium: internal signalling and output control

    DEFF Research Database (Denmark)

    Bie, P

    2009-01-01

    Total body sodium and arterial blood pressure (ABP) are mutually dependent variables regulated by complex control systems. This review addresses the role of ABP in the normal control of sodium excretion (NaEx), and the physiological control of renin secretion. NaEx is a pivotal determinant of ABP......, and under experimental conditions, ABP is a powerful, independent controller of NaEx. Blood volume is a function of dietary salt intake; however, ABP is not, at least not in steady states. A transient increase in ABP after a step-up in sodium intake could provide a causal relationship between ABP...... and the regulation of NaEx via a hypothetical integrative control system. However, recent data show that subtle sodium loading (simulating salty meals) causes robust natriuresis without changes in ABP. Changes in ABP are not necessary for natriuresis. Normal sodium excretion is not regulated by pressure. Plasma...

  2. Study of air pollution in terms of heavy metals and particulate matter at Ambodin'isotry using the technique of total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    AHMED, H.

    2011-01-01

    The present work is devoted to study the air pollution in terms of particulate matters and heavy metals in Ambodin'isotry in Antananarivo city by the method of total reflection X-ray fluorescence. This work has been done within the Institut National des Sciences et Techniques Nucleaires (Madagascar-INSTN). GENT air sampler has been used for the collections of the aerosol samples. This air sampler is placed at about 7 meters above the ground in order to avoid the contaminations. The samplings were carried out from 14 April to 29 August 2008. The duration of sampling is 24 hours. The results show that the analyzed aerosol samples contain the elements like the titanium , the chromium, the manganese, the iron, the nickel, the copper, the zinc, the bromine, the strontium and the lead. The average concentrations in element lead are lower than the standards ones adopted by the World Health Organization (WHO) (500 ng.m -3 ) and the United States Environmental Protection Agency (US EPA) (1500 ng.m -3 ). The total average concentrations in element lead are lower than the standards ones adopted by the World Health Organization (WHO) (500 ng.m -3 ). The total of average concentrations in lead doesn't present a danger for the population of Ambodin'isotry. The average concentrations of PM10 in the aerosols do not respect the guideline values of 50μg.m -3 adopted by the WHO and the European Union according to the directive 2005 and those of PM 2.5 exceed extensively the guideline values of the WHO (25μg.m -3 ) and of the US EPA (35μg.m -3 ). Consequently, the site of Ambodin'Isotry is polluted in term of airborne particulate matters. The calculation of enrichment factors by Mason's model shows the titanium, the iron, the nickel and the strontium are natural origin while the chromium, the nickel, the copper, the zinc, the bromine and the lead are from anthropogenic sources. [fr

  3. Two different preparation techniques for trace element determination of single Daphnia specimen using total reflection x-ray fluorescence analysis (TXRF)

    International Nuclear Information System (INIS)

    Woelfl, S.; Mages, M.

    2000-01-01

    Bio accumulation gives first information about the bio-availability of elements in waters and becomes more and more important for the characterization of the water quality. The use of common analytical techniques like ICP-MS and AAS requires large quantities of biologic sample material. Single preparation for example of Daphnia, a common species for bio-test experiments, are hardly possible with these procedures. Therefore alternatively quantitative TXRF element determination of individually prepared Daphnia was developed. Two preparation techniques for single freshwater crustacean specimen from a eutrophic branch of the river Elbe in the 'Rothehorn Park', Magdeburg (Daphnia: dry weight: 10 - 50 μg individuum -1 ) had been tested: (1) Wet preparation: the single Daphnia specimen had been washed with 0.45 μm filtered lake water and put onto quartz sample carriers. After air drying, the body length were determined in order to calculate the dry weight according to previously established body lengths-dry weight relationships. (2) Dry preparation: after collection specimen were washed with 0.45 μm filtered lake water and frozen in liquid nitrogen. The individual lyophilisated dried Daphnia were weighted using an ultrafine micro-balance and put onto quartz sample carriers. After preparation, addition of some μl Gallium standard solution and air drying the individual Daphnia were digested at the quartz sample carriers with 10 μl HNO 3 on a hot plate and dried once more. Finally the element concentrations were determined using a EXTRA IIA total-reflection x-ray fluorescence spectrometer. As a result of these investigations we can conclude that both, the 'dry' and 'wet' preparation method can be used for the element determination in small single crustaceans using TXRF spectrometry. It seems that the 'dry' method yields more precise results, but the wet method is easier to handle in field when samples cannot be fixed with liquid nitrogen. (author)

  4. Enamel Mineral Content Changes After Bleaching With High and Low Hydrogen Peroxide Concentrations: Colorimetric Spectrophotometry and Total Reflection X-ray Fluorescence Analyses.

    Science.gov (United States)

    Pinto, Avd; Bridi, E C; Amaral, Flb; França, Fmg; Turssi, C P; Pérez, C A; Martinez, E F; Flório, F M; Basting, R T

    The purpose of this study was to evaluate the calcium (Ca) and phosphorous (P) content in enamel bleached with high and low concentrations of hydrogen peroxide (HP) using Total Reflection X-Ray Fluorescence (TXRF) and colorimetric spectrophotometry (SPEC). Forty-eight sound human third molars were used. Their roots were embedded in polystyrene resin and immersed for seven days in an artificial saliva solution. Then they were distributed into six groups to receive the bleaching treatments. The agents of high HP concentration (for in-office use) evaluated were Whiteness HP Maxx/FGM (35% HP), Whiteness HP Blue/FGM (35% HP, 2% calcium gluconate), Pola Office+/SDI (37.5% HP, 5% potassium nitrate), and Opalescence Boost/Ultradent (38% HP, 1.1% ion fluoride, 3% potassium nitrate); these agents were applied to enamel in three sessions. The agents of low HP concentration (for home use) evaluated were Pola Day/SDI (9.5% HP) and White Class 10%/FGM (10% HP, potassium nitrate, calcium, fluoride), and these agents were applied for 14 days. Enamel microbiopsies were evaluated by TXRF and SPEC analysis before the bleaching treatment (baseline), during the treatment, and 14 days after the end of the treatment. For TXRF, the Kruskal-Wallis test showed that Ca and P were not influenced by agent (p>0.05). For SPEC, Pola Office+, Opalescence Boost, Pola Day, and White Class 10% caused a decrease of Ca over time; there was a significant decrease of P over time to Pola Office+ and White Class 10%. The Spearman test showed no correlation between the Ca (p=0.987; r 2 =-0.020) and P (p=0.728, r 2 =0.038) obtained by SPEC and TXRF. For TXRF and SPEC, changes in Ca and P during bleaching occurred independently of the HP concentration used.

  5. Multielement analysis of swiss mice brains with Alzheimer's disease induced by beta amyloid oligomers using a portable total reflection X-ray fluorescence system

    International Nuclear Information System (INIS)

    Almeida, Danielle S.; Brigido, Matheus M.; Anjos, Marcelino J.; Ferreira, Sergio S.; Souza, Amanda S.; Lopes, Ricardo T.

    2017-01-01

    Alzheimer's disease (AD) is a progressive dementia that, in early stages, manifests as a profound inability to form new memories. The pathological features of AD include β-amyloid (Aβ) plaques, intracellular neurofibrillary tangles, loss of neurons and synapses, and activation of glia cells. Recently, several groups have raised the 'metal hypothesis' of AD. Metal ions, such as Cu and Zn, have been demonstrated to modulate amyloid aggregation along different pathways. Extensive research has been conducted on the effects of metals on Aβ aggregation and all of them have shown that both Cu and Zn accelerate the aggregation by shortening, or eliminating, the lag phase associated with the amyloid fibrillation process. The metal ions mentioned previously may have an important impact on the protein misfolding and the progression of the neurodegenerative process. The TXRF technique is very important, because can be used to identify and quantify trace elements present in the sample at very low concentrations (μg.g"-"1). In this work, three groups of females were studied: control, AD10 and AD100. The groups AD10 and AD100 were given a single intracerebroventricular injection of 10 pmol and 100 pmol of oligomers of β-amyloid peptide respectively to be induced AD. The TXRF measurements were performed using a portable total reflection X-ray fluorescence system developed in the Laboratory of Nuclear Instrumentation (LIN/UFRJ) that uses an X-ray tube with a molybdenum anode operating at 40 kV and 500 mA used for the excitation and a detector Si-PIN with energy resolution of 145 eV at 200 eV. It was possible to determine the concentrations of the following elements: P, S, K, Fe, Cu, Zn and Rubidium. Results showed differences in the elemental concentration in some brain regions between the AD groups and the control group. (author)

  6. Multielement analysis of swiss mice brains with Alzheimer's disease induced by beta amyloid oligomers using a portable total reflection X-ray fluorescence system

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Danielle S.; Brigido, Matheus M.; Anjos, Marcelino J.; Ferreira, Sergio S.; Souza, Amanda S.; Lopes, Ricardo T., E-mail: ricardo@lin.ufrj.br, E-mail: marcelin@uerj.br, E-mail: amandass@bioqmed.ufrj.br, E-mail: ferreira@bioqmed.ufrj.br, E-mail: amandass@bioqmed.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil); Instituto de Fisica Armando Dias Tavares (Brazil)

    2017-11-01

    Alzheimer's disease (AD) is a progressive dementia that, in early stages, manifests as a profound inability to form new memories. The pathological features of AD include β-amyloid (Aβ) plaques, intracellular neurofibrillary tangles, loss of neurons and synapses, and activation of glia cells. Recently, several groups have raised the 'metal hypothesis' of AD. Metal ions, such as Cu and Zn, have been demonstrated to modulate amyloid aggregation along different pathways. Extensive research has been conducted on the effects of metals on Aβ aggregation and all of them have shown that both Cu and Zn accelerate the aggregation by shortening, or eliminating, the lag phase associated with the amyloid fibrillation process. The metal ions mentioned previously may have an important impact on the protein misfolding and the progression of the neurodegenerative process. The TXRF technique is very important, because can be used to identify and quantify trace elements present in the sample at very low concentrations (μg.g{sup -1}). In this work, three groups of females were studied: control, AD10 and AD100. The groups AD10 and AD100 were given a single intracerebroventricular injection of 10 pmol and 100 pmol of oligomers of β-amyloid peptide respectively to be induced AD. The TXRF measurements were performed using a portable total reflection X-ray fluorescence system developed in the Laboratory of Nuclear Instrumentation (LIN/UFRJ) that uses an X-ray tube with a molybdenum anode operating at 40 kV and 500 mA used for the excitation and a detector Si-PIN with energy resolution of 145 eV at 200 eV. It was possible to determine the concentrations of the following elements: P, S, K, Fe, Cu, Zn and Rubidium. Results showed differences in the elemental concentration in some brain regions between the AD groups and the control group. (author)

  7. Tracer-based laser-induced fluorescence measurement technique for quantitative fuel/air-ratio measurements in a hydrogen internal combustion engine.

    Science.gov (United States)

    Blotevogel, Thomas; Hartmann, Matthias; Rottengruber, Hermann; Leipertz, Alfred

    2008-12-10

    A measurement technique for the quantitative investigation of mixture formation processes in hydrogen internal combustion engines (ICEs) has been developed using tracer-based laser-induced fluorescence (TLIF). This technique can be employed to fired and motored engine operation. The quantitative TLIF fuel/air-ratio results have been verified by means of linear Raman scattering measurements. Exemplary results of the simultaneous investigation of mixture formation and combustion obtained at an optical accessible hydrogen ICE are shown.

  8. Correlation of glenohumeral internal rotation deficit and total rotational motion to shoulder injuries in professional baseball pitchers.

    Science.gov (United States)

    Wilk, Kevin E; Macrina, Leonard C; Fleisig, Glenn S; Porterfield, Ronald; Simpson, Charles D; Harker, Paul; Paparesta, Nick; Andrews, James R

    2011-02-01

    Glenohumeral internal rotation deficit (GIRD) indicates a 20° or greater loss of internal rotation of the throwing shoulder compared with the nondominant shoulder. To determine whether GIRD and a deficit in total rotational motion (external rotation + internal rotation) compared with the nonthrowing shoulder correlate with shoulder injuries in professional baseball pitchers. Case series; Level of evidence, 4. Over 3 competitive seasons (2005 to 2007), passive range of motion measurements were evaluated on the dominant and nondominant shoulders for 170 pitcher-seasons. This included 122 professional pitchers during the 3 seasons of data collection, in which some pitchers were measured during multiple seasons. Ranges of motion were measured with a bubble goniometer during the preseason, by the same examiner each year. External and internal rotation of the glenohumeral joint was assessed with the participant supine and the arm abducted 90° in the plane of the scapula, with the scapula stabilized anteriorly at the coracoid process. The reproducibility of the test methods had an intraclass correlation coefficient of .81. Days in which the player was unable to participate because of injury or surgery were recorded during the season by the medical staff of the team and defined as an injury. Pitchers with GIRD (n = 40) were nearly twice as likely to be injured as those without but without statistical significance (P = .17). Pitchers with total rotational motion deficit greater than 5° had a higher rate of injury. Minor league pitchers were more likely than major league pitchers to be injured. However, when players were injured, major league pitchers missed a significantly greater number of games than minor league pitchers. Compared with pitchers without GIRD, pitchers with GIRD appear to be at a higher risk for injury and shoulder surgery.

  9. A small-displacement sensor using total internal reflection theory and surface plasmon resonance technology for heterodyne interferometry.

    Science.gov (United States)

    Wang, Shinn-Fwu

    2009-01-01

    A small-displacement sensor based on total-internal reflection theory and surface plasmon resonance technology is proposed for use in heterodyne interferometry. A small displacement can be obtained simply by measuring the variation in phase difference between s- and p-polarization states with the small-displacement sensor. The theoretical displacement resolution of the small-displacement sensor can reach 0.45 nm. The sensor has some additional advantages, e.g., a simple optical setup, high resolution, high sensitivity and rapid measurement. Its feasibility is also demonstrated.

  10. High accuracy subwavelength distance measurements: A variable-angle standing-wave total-internal-reflection optical microscope

    International Nuclear Information System (INIS)

    Haynie, A.; Min, T.-J.; Luan, L.; Mu, W.; Ketterson, J. B.

    2009-01-01

    We describe an extension of the total-internal-reflection microscopy technique that permits direct in-plane distance measurements with high accuracy (<10 nm) over a wide range of separations. This high position accuracy arises from the creation of a standing evanescent wave and the ability to sweep the nodal positions (intensity minima of the standing wave) in a controlled manner via both the incident angle and the relative phase of the incoming laser beams. Some control over the vertical resolution is available through the ability to scan the incoming angle and with it the evanescent penetration depth.

  11. All-optical microscope autofocus based on an electrically tunable lens and a totally internally reflected IR laser.

    Science.gov (United States)

    Bathe-Peters, M; Annibale, P; Lohse, M J

    2018-02-05

    Microscopic imaging at high spatial-temporal resolution over long time scales (minutes to hours) requires rapid and precise stabilization of the microscope focus. Conventional and commercial autofocus systems are largely based on piezoelectric stages or mechanical objective actuators. Objective to sample distance is either measured by image analysis approaches or by hardware modules measuring the intensity of reflected infrared light. We propose here a truly all-optical microscope autofocus taking advantage of an electrically tunable lens and a totally internally reflected infrared probe beam. We implement a feedback-loop based on the lateral position of a totally internally reflected infrared laser on a quadrant photodetector, as an indicator of the relative defocus. We show here how to treat the combined contributions due to mechanical defocus and deformation of the tunable lens. As a result, the sample can be kept in focus without any mechanical movement, at rates up to hundreds of Hertz. The device requires only reflective optics and can be implemented at a fraction of the cost required for a comparable piezo-based actuator.

  12. The Moon's Moment in the Sun - Extending Public Engagement after the Total Solar Eclipse with International Observe the Moon Night

    Science.gov (United States)

    Bleacher, L.; Jones, A. P.; Wasser, M. L.; Petro, N. E.; Wright, E. T.; Ladd, D.; Keller, J. W.

    2017-12-01

    2017 presented an amazing opportunity to engage the public in learning about lunar and space science, the motions of the Earth-Moon-Sun system, and NASA's fleet of space missions, beginning with the 2017 total solar eclipse on 21 August and continuing with International Observe the Moon Night (InOMN) on 28 October. On 21 August 2017, everyone in the continental United States had the opportunity to witness a solar eclipse, weather permitting, in total or partial form. The path of totality, in which the Sun was completely obscured from view by the Moon, stretched from Oregon to South Carolina. The Education and Communication Team of NASA's Lunar Reconnaissance Orbiter (LRO) worked to highlight the Moon, the "central player" in the total solar eclipse, in a variety of ways for the public. Efforts included collaborating with Minor League Baseball teams to host eclipse-viewing events along the path of totality, communicating the Moon's role in the eclipse through public engagement products, communicating about InOMN as an experiential opportunity beyond the eclipse, and more. InOMN is an annual event, during which everyone on Earth is invited to observe and learn about the Moon and its connection to planetary science, and to share personal and community connections we all have to the Moon [2, 3, 4 and references therein]. For viewers across the United States, the total solar eclipse of 21 August provided an exciting opportunity to watch a New Moon cross in front of the Sun, casting the viewer in shadow and providing amazing views of the solar corona. The public observed the Moon in a different part of its orbit, when reflected sunlight revealed a fascinating lunar landscape - and extended their excitement for space science - by participating in InOMN on 28 October. With InOMN taking place barely two months after the total solar eclipse, it offered an opportunity to sustain and grow public interest in lunar and space science generated by the eclipse. We will report on

  13. Investigation of the Unsteady Total Pressure Profile Corresponding to Counter-Rotating Vortices in an Internal Flow Application

    Science.gov (United States)

    Gordon, Kathryn; Morris, Scott; Jemcov, Aleksandar; Cameron, Joshua

    2013-11-01

    The interaction of components in a compressible, internal flow often results in unsteady interactions between the wakes and moving blades. A prime example in which this flow feature is of interest is the interaction between the downstream rotor blades in a transonic axial compressor with the wake vortices shed from the upstream inlet guide vane (IGV). Previous work shows that a double row of counter-rotating vortices convects downstream into the rotor passage as a result of the rotor blade bow shock impinging on the IGV. The rotor-relative time-mean total pressure distribution has a region of high total pressure corresponding to the pathline of the vortices. The present work focuses on the relationship between the magnitude of the time-mean rotor-relative total pressure profile and the axial spacing between the IGV and the rotor. A survey of different axial gap sizes is performed in a two-dimensional computational study to obtain the sensitivity of the pressure profile amplitude to IGV-rotor axial spacing.

  14. Fast Focal Point Correction in Prism-Coupled Total Internal Reflection Scanning Imager Using an Electronically Tunable Lens

    Directory of Open Access Journals (Sweden)

    Chenggang Zhu

    2018-02-01

    Full Text Available Total internal reflection (TIR is useful for interrogating physical and chemical processes that occur at the interface between two transparent media. Yet prism-coupled TIR imaging microscopes suffer from limited sensing areas due to the fact that the interface (the object plane is not perpendicular to the optical axis of the microscope. In this paper, we show that an electrically tunable lens can be used to rapidly and reproducibly correct the focal length of an oblique-incidence scanning microscope (OI-RD in a prism-coupled TIR geometry. We demonstrate the performance of such a correction by acquiring an image of a protein microarray over a scan area of 4 cm2 with an effective resolution of less than 20 microns. The electronic focal length tuning eliminates the mechanical movement of the illumination lens in the scanning microscope and in turn the noise and background drift associated with the motion.

  15. Total internal reflection sum-frequency generation spectroscopy and dense gold nanoparticles monolayer: a route for probing adsorbed molecules

    International Nuclear Information System (INIS)

    Tourillon, Gerard; Dreesen, Laurent; Volcke, Cedric; Sartenaer, Yannick; Thiry, Paul A; Peremans, Andre

    2007-01-01

    We show that sum-frequency generation spectroscopy performed in the total internal reflection configuration (TIR-SFG) combined with a dense gold nanoparticles monolayer allows us to study, with an excellent signal to noise ratio and high signal to background ratio, the conformation of adsorbed molecules. Dodecanethiol (DDT) was used as probe molecules in order to assess the potentialities of the approach. An enhancement of more than one order of magnitude of the SFG signals arising from the adsorbed species is observed with the TIR geometry compared to the external reflection one while the SFG non-resonant contribution remains the same for both configurations. Although further work is required to fully understand the origin of the SFG process on nanoparticles, our work opens new possibilities for studying nanostructures

  16. Attenuated total internal reflection infrared microspectroscopic imaging using a large-radius germanium internal reflection element and a linear array detector.

    Science.gov (United States)

    Patterson, Brian M; Havrilla, George J

    2006-11-01

    The number of techniques and instruments available for Fourier transform infrared (FT-IR) microspectroscopic imaging has grown significantly over the past few years. Attenuated total internal reflectance (ATR) FT-IR microspectroscopy reduces sample preparation time and has simplified the analysis of many difficult samples. FT-IR imaging has become a powerful analytical tool using either a focal plane array or a linear array detector, especially when coupled with a chemometric analysis package. The field of view of the ATR-IR microspectroscopic imaging area can be greatly increased from 300 x 300 microm to 2500 x 2500 microm using a larger internal reflection element of 12.5 mm radius instead of the typical 1.5 mm radius. This gives an area increase of 70x before aberrant effects become too great. Parameters evaluated include the change in penetration depth as a function of beam displacement, measurements of the active area, magnification factor, and change in spatial resolution over the imaging area. Drawbacks such as large file size will also be discussed. This technique has been successfully applied to the FT-IR imaging of polydimethylsiloxane foam cross-sections, latent human fingerprints, and a model inorganic mixture, which demonstrates the usefulness of the method for pharmaceuticals.

  17. Dendrochemical patterns of calcium, zinc, and potassium related to internal factors detected by energy dispersive X-ray fluorescence (EDXRF)

    Science.gov (United States)

    Kevin T. Smith; Jean Christophe Balouet; Walter C. Shortle; Michel Chalot; François Beaujard; Hakan Grudd; Don A. Vroblesky; Joel G. Burken

    2014-01-01

    Energy dispersive X-ray fluorescence (EDXRF) provides highly sensitive and precise spatial resolution of cation content in individual annual growth rings in trees. The sensitivity and precision have prompted successful applications to forensic dendrochemistry and the timing of environmental releases of contaminants. These applications have highlighted the need to...

  18. Trace element analysis of water using radioisotope induced X-ray fluorescence (Cd-109) and a preconcentration-internal standard method

    International Nuclear Information System (INIS)

    Alvarez, M.; Cano, W.

    1986-10-01

    Radioisotope induced X-ray fluorescence using Cd-109 was used for the determination of iron, nickel, copper, zinc, lead and mercury in water. These metals were concentrated by precipitation with the chelating agent APDC. The precipitated formed was filtered using a membrane filter. Cobalt was added as an internal standard. Minimum detection limit, sensitivities and calibration curves linearities have been obtained to find the limits of the method. The usefulness of the method is illustrated analysing synthetic standard solutions. As an application analytical results are given for water of a highly polluted river area. (Author)

  19. Preliminary study on the inhibition of nuclear internalization of Tat peptides by conjugation with a receptor-specific peptide and fluorescent dyes

    Science.gov (United States)

    Shen, Duanwen; Liang, Kexiang; Ye, Yunpeng; Tetteh, Elizabeth; Achilefu, Samuel

    2006-02-01

    Numerous studies have shown that basic Tat peptide (48-57) internalized non-specifically in cells and localized in the nucleus. However, localization of imaging agents in cellular nucleus is not desirable because of the potential mutagenesis. When conjugated to the peptides that undergo receptor-mediated endocytosis, Tat peptide could target specific cells or pathologic tissue. We tested this hypothesis by incorporating a somatostatin receptor-avid peptide (octreotate, Oct) and two different fluorescent dyes, Cypate 2 (Cy2) and fluorescein 5'-carboxlic acid (5-FAM), into the Tat-peptide sequence. In addition to the Cy2 or 5-FAM-labeled Oct conjugated to Tat peptide (Tat) to produce Tat-Oct-Cypate2 or Tat-Oct-5-FAM, we also labeled the Tat the Tat peptide with these dyes (Tat-Cy2 and Tat-5-FAM) to serve as positive control. A somatostatin receptor-positive pancreatic tumor cell line, AR42J, was used to assess cell internalization. The results show that Tat-5-FAM and Tat-Cypate2 localized in both nucleus and cytoplasm of the cells. In contrast to Tat-Oct-Cypate2, which localized in both the cytoplasm and nucleus, Tat-Oct-5-FAM internalized in the cytoplasm but not in the nucleus of AR42J cells. The internalizations were inhibited by adding non-labeled corresponding peptides, suggesting that the endocytoses of each group of labeled and the corresponding unlabeled compounds occurred through a common pathway. Thus, fluorescent probes and endocytosis complex between octreotate and somatostatin receptors in cytoplasm could control nuclear internalization of Tat peptides.

  20. Use of X-ray fluorescence with energy dispersion, and the total reflexions in the analysis of environmental samples; Uso da fluorescencia de raios X com dispersao de energia e da reflexao total na analise de amostras ambientais

    Energy Technology Data Exchange (ETDEWEB)

    Simabuco, Silvana Moreira [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Civil; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)

    1996-12-31

    This communication reports the present status of the research on the use of wavelength dispersive X-ray fluorescence and radioisotopic excitation for quantitative analysis of environmental samples. Simultaneous instrumental determination of various element concentration have been performed, particularly Al, Si, S, Cl, K, Ca, Ti, Mn, Fe, Cu, Zn, Rb, Zr and Nb existent in soils with different textures. Also, quantitative analysis has been performed on sediment samples, based on the fundamental parameters for quantification of Z >= 13 elements, and the coherent and incoherent scattered excitation radiation for quantification of the matrix (Z < 13) light fraction 16 refs., 1 fig.

  1. International Review Team (IRT) Safety Case Recommendations for the Yucca Mountain Total System Performance Assessment (TSPA) Supporting the Site Recommendation

    International Nuclear Information System (INIS)

    Van Luik, Abraham E.

    2004-01-01

    The session started with Abe Van Luik (IGSC Chair, US-DOE-YM, USA) who presented the feedback of the international peer review of the US-DOE Yucca Mountain TSPA (Total System Performance Assessment) supporting the successful designation of the site by the Congress and the President of the U.S. In particular, he listed key implications of the IRT (International Review team) recommendations on the forthcoming US-DOE documentation of its case for safety to be submitted to the regulator, the U.S. Nuclear Regulatory Commission, mainly: - The documentation submitted to the licensing authority should address technical aspects and compliance with regulatory criteria. - That documentation should reflect sound science and good engineering practice; it should present detailed and rigorous modelling. - In addition, it should present both quantitative and qualitative arguments, make a statement on why there can be confidence in the face of uncertainty, acknowledge remaining issues and provide the strategy to resolve them. - Demonstrating understanding is as important as demonstrating compliance. - There is a need to provide a clear explanation of the case made to the regulator for more general audiences to complement the large amount of technical documents that will be produced. The US-DOE response to these recommendations for the License Application, which is under preparation, is that the recommendations will be implemented to the maximum extent possible. In subsequent discussion, with respect to the License Application, it was acknowledged that detailed guidance from the U.S. regulator was very useful, and guidance of this type would be generally useful. At the current time, the words 'safety case' are not mentioned in U.S. regulations, but if one reads both the regulation and guidance documents it becomes evident that all aspects of a safety case need to be provided in the License Application and its accompanying documents

  2. Characterization of the external and internal flow structure of an aerated-liquid injector using X-ray radiography and fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, Scott J.; Lin, Kuo-Cheng; Carter, Campbell D.; Kastengren, Alan L.

    2017-08-02

    In the present study, the internal flowfield of aerated-liquid fuel injectors is examined through x-ray radiography and x-ray fluorescence. An inside-out injector, consisting of a perforated aerating tube within an annular liquid stream, sprays into a quiescent environment at a fixed mass flow rate of water and nitrogen gas. The liquid is doped with bromine (in the form of NaBr) to create an x-ray fluorescence signal. This allows for reasonable absorption and fluorescence signals, and one or both diagnostics can be used to track the liquid distribution. The injector housing is fabricated from beryllium (Be), which allows the internal flowfield to be examined (as Be has relatively low x-ray attenuation coefficient). Two injector geometries are compared, illustrating the effects of aerating orifice size and location on the flow evolution. Time-averaged equivalent pathlength (EPL) and line-of-sight averaged density ρ(y) reveal the formation of the two-phase mixture, showing that the liquid film thickness along the injector walls is a function of the aerating tube geometry, though only upstream of the nozzle. These differences in gas and liquid distribution (between injectors with different aerating tube designs) are suppressed as the mixture traverses the nozzle contraction. The averaged liquid velocity (computed from the density and liquid mass flow rate) reveal a similar trend. This suggests that at least for the current configurations, the plume width, liquid mass distribution, and averaged liquid velocity for the time-averaged external spray are insensitive to the aerating tube geometry.

  3. Characterization of the external and internal flow structure of an aerated-liquid injector using X-ray radiography and fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, Scott J. [Aerospace Systems Directorate, Air Force Research Laboratory, Arnold AFB, TN (United States); Lin, Kuo-Cheng [Taitech, Inc., Beavercreek, OH (United States); Carter, Campbell D. [Aerospace Systems Directorate, Air Force Research Laboratory, Wright-Patterson AFB, OH (United States); Kastengren, Alan L. [Argonne National Laboratory, X-Ray Science Division, Advanced Photon Source, Argonne, IL (United States)

    2017-09-15

    In the present study, the internal flowfield of aerated-liquid fuel injectors is examined through X-ray radiography and X-ray fluorescence. An inside-out injector, consisting of a perforated aerating tube within an annular liquid stream, sprays into a quiescent environment at a fixed mass flow rate of water and nitrogen gas. The liquid is doped with bromine (in the form of NaBr) to create an X-ray fluorescence signal. This allows for reasonable absorption and fluorescence signals, and one or both diagnostics can be used to track the liquid distribution. The injector housing is fabricated from beryllium (Be), which allows the internal flowfield to be examined (as Be has relatively low X-ray attenuation coefficient). Two injector geometries are compared, illustrating the effects of aerating orifice size and location on the flow evolution. Time-averaged equivalent pathlength and line-of-sight averaged density ρ(y) reveal the formation of the two-phase mixture, showing that the liquid film thickness along the injector walls is a function of the aerating tube geometry, though only upstream of the nozzle. These differences in gas and liquid distribution (between injectors with different aerating tube designs) are suppressed as the mixture traverses the nozzle contraction. The averaged liquid velocity (computed from the density and liquid mass flow rate) reveals a similar trend. This suggests that at least for the current configurations, the plume width, liquid mass distribution, and averaged liquid velocity for the time-averaged external spray are insensitive to the aerating tube geometry. (orig.)

  4. Planar solar concentrator featuring alignment-free total-internal-reflection collectors and an innovative compound tracker.

    Science.gov (United States)

    Teng, Tun-Chien; Lai, Wei-Che

    2014-12-15

    This study proposed a planar solar concentrator featuring alignment-free total-internal-reflection (TIR) collectors and an innovative compound tracker. The compound tracker, combining a mechanical single-axis tracker and scrollable prism sheets, can achieve a performance on a par with dual-axis tracking while reducing the cost of the tracking system and increasing its robustness. The alignment-free TIR collectors are assembled on the waveguide without requiring alignment, so the planar concentrator is relatively easily manufactured and markedly increases the feasibility for use in large concentrators. Further, the identical TIR collector is applicable to various-sized waveguide slab without requiring modification, which facilitates flexibility regarding the size of the waveguide slab. In the simulation model, the thickness of the slab was 2 mm, and its maximal length reached 6 m. With an average angular tolerance of ±0.6°, and after considering both the Fresnel loss and the angular spread of the sun, the simulation indicates that the waveguide concentrator of a 1000-mm length provides the optical efficiencies of 62-77% at the irradiance concentrations of 387-688, and the one of a 2000-mm length provides the optical efficiencies of 52-64.5% at the irradiance concentrations of 645-1148. Alternatively, if a 100-mm horizontally staggered waveguide slab is collocated with the alignment-free TIR collectors, the optical efficiency would be greatly improved up to 91.5% at an irradiance concentration of 1098 (C(geo) = 1200X).

  5. The Advantages of an Attenuated Total Internal Reflection Infrared Microspectroscopic Imaging Technique for the Analysis of Polymer Laminates.

    Science.gov (United States)

    Ling, Chen; Sommer, André J

    2015-06-01

    Until recently, the analysis of polymer laminates using infrared microspectroscopy involved the painstaking separation of individual layers by dissection or by obtaining micrometer thin cross-sections. The latter usually requires the expertise of an individual trained in microtomy and even then, the very structure of the laminate could affect the outcome of the spectral results. The recent development of attenuated total internal reflection (ATR) infrared microspectroscopy imaging has provided a new avenue for the analysis of these multilayer structures. This report compares ATR infrared microspectroscopy imaging with conventional transmission infrared microspectroscopy imaging. The results demonstrate that the ATR method offers improved spatial resolution, eliminates a variety of competing optical processes, and requires minimal sample preparation relative to transmission measurements. These advantages were illustrated using a polymer laminate consisting of 11 different layers whose thickness ranged in size from 4-20 μm. The spatial resolution achieved by using an ATR-FTIR (Fourier transform infrared spectroscopy) imaging technique was diffraction limited. Contrast in the ATR images was enhanced by principal component analysis.

  6. International comparative evaluation of fixed-bearing non-posterior-stabilized and posterior-stabilized total knee replacements.

    Science.gov (United States)

    Comfort, Thomas; Baste, Valborg; Froufe, Miquel Angel; Namba, Robert; Bordini, Barbara; Robertsson, Otto; Cafri, Guy; Paxton, Elizabeth; Sedrakyan, Art; Graves, Stephen

    2014-12-17

    Differences in survivorship of non-posterior-stabilized compared with posterior-stabilized knee designs carry substantial economic consequences, especially with limited health-care resources. However, these comparisons have often been made between relatively small groups of patients, often with short-term follow-up, with only small differences demonstrated between the groups. The goal of this study is to compare the outcomes of non-posterior-stabilized and posterior-stabilized total knee arthroplasties with use of a unique collaboration of multiple established knee arthroplasty registries. A distributed health data network was developed by the International Consortium of Orthopaedic Registries and was used in this study to reduce barriers to participation (such as security, propriety, legal, and privacy issues) compared with a centralized data warehouse approach. The study included only replacements in osteoarthritis patients who underwent total knee procedures involving fixed-bearing devices from 2001 to 2010. The outcome of interest was time to first revision. On average, not resurfacing showed a more harmful effect than resurfacing did when posterior-stabilized and non-posterior-stabilized knee replacements were compared, while the risk of revision for posterior-stabilized compared with non-posterior-stabilized knees was highest in year zero to one, followed by year one to two, years eight through ten, and years two through eight. Posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did when the patella was not resurfaced. This difference was most pronounced in the first two years (year zero to one: hazard ratio [HR] = 2.15, 95% confidence interval [CI] = 1.56 to 2.95, p < 0.001; year one to two: HR = 1.61, 95% CI = 1.48 to 1.75, p < 0.001). When the patella was resurfaced, posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did. This was again most pronounced in the first two years (year zero

  7. Prismatic TIR (total internal reflection) low-concentration PV (photovoltaics)-integrated façade for low latitudes

    International Nuclear Information System (INIS)

    Sabry, Mohamed

    2016-01-01

    Low-concentration Façade-integrated Photovoltaic system in the form of TIR (total internal reflection) prismatic segmented façade could play an effective role in reducing the direct component of solar radiation transmitting through buildings, hence reducing both cooling and artificial lighting load on such buildings. A prismatic segmented façade is capable of allowing diffused skylight to transmit through it to the building interior, while preventing most of the direct solar radiation and converting it into clean energy by means of the integrated PV (​photovoltaics) cells. A range of prismatic TIR segmented façades with different head angles has been designed based on the geographical latitude of the chosen location. Each façade configuration is simulated by ray-tracing technique and its performance is investigated against realistic direct solar radiation data in two clear sky days representing summer and winter of the targeted location. Ray tracing simulations revealed that all of the selected configurations could collect most of the direct solar radiation in summer. In contrary, larger head angle of the segmented façade could collect wider intervals around the noon time till reaching a head angle of 23° at which most of the incident direct solar radiation could be collected. - Highlights: • 5 different head angles of prismatic segmented PV-integrated Façade are ray-traced. • Transmitted and PV-collected solar radiation percentages are determined. • DNI daily profiles with associated solar altitudes and azimuth data are simulated. • Expected transmitted and PV collected solar radiation are calculated for the proposed segments.

  8. Invited Article: An active terahertz polarization converter employing vanadium dioxide and a metal wire grating in total internal reflection geometry

    Science.gov (United States)

    Liu, Xudong; Chen, Xuequan; Parrott, Edward P. J.; Han, Chunrui; Humbert, Georges; Crunteanu, Aurelian; Pickwell-MacPherson, Emma

    2018-05-01

    Active broadband terahertz (THz) polarization manipulation devices are challenging to realize, but also of great demand in broadband terahertz systems. Vanadium dioxide (VO2) shows a promising phase transition for active control of THz waves and provides broadband polarization characteristics when integrated within grating-type structures. We creatively combine a VO2-based grating structure with a total internal reflection (TIR) geometry providing a novel interaction mechanism between the electromagnetic waves and the device, to realize a powerful active broadband THz polarization-controlling device. The device is based on a Si-substrate coated with a VO2 layer and a metal grating structure on top, attached to a prism for generating the TIR condition on the Si-VO2-grating interface. The grating is connected to electrodes for electrically switching the VO2 between its insulating and conducting phases. By properly selecting the incident angle of the THz waves, the grating direction, and the incident polarization state, we first achieved a broadband intensity modulator under a fused silica prism with an average modulation depth of 99.75% in the 0.2-1.1 THz region. Additionally, we realized an active ultra-broadband quarter-wave converter under a Si prism that can be switched between a 45° linear rotator and a quarter wave converter in the 0.8-1.5 THz region. This is the first demonstration of an active quarter-wave converter with ultra-broad bandwidth performance. Our work shows a highly flexible and multifunctional polarization-controlling device for broadband THz applications.

  9. Trace elements in airborne particles in internal industrial environments: spectrometric analysis of x-ray fluorescence (XRF)

    International Nuclear Information System (INIS)

    Salazar Matarrita, Alfonso

    2001-01-01

    Fluorescence spectroscopy x-ray, is a technique of non-destructive analysis, that allows quantitative determination of the absolute concentration of chemical elements that make up a given matrix. The detected elements depend on atomic number and energy of the secondary target used for irradiation of samples. X-rays are detected and counted in a spectroscopy system based on a multichannel analyzer, that discriminates by energy and form a spectrum of independent photopeaks, whose energy identifies the element and its intensity is proportional to its concentration. The quantification requires the irradiation and counting of a set of pattern comparators, of the same elements identified in the samples. The x-ray emission shows only during the time that the selected sample is subjected to irradiation by x-ray tube. This irradiation does not change the structure nor the chemical composition of the matrix, so the sample remains unchanged, after irradiation. This condition non-destructive characterizes the fluorescence x-ray. The trace elements present in airborne particles, are determined and collected on a Nuclepore filter. The collection sites selected are: Taller de Mecanica de Precision de la Escuela de Fisica, Universidad de Costa Rica; Taller J. V. G. Precision, San Antonio de Coronado; Taller de Muflas, MUFLASA, Alto de Guadalupe; Industria Silvania S. A., Pavas. In addition, it is attached the service rendered to the enterprise Sellos Generales S. A. The working conditions and physical conditions of facilities were considered. An aerosol sampler with a temporal variation was used. Irradiation of samples and an evaluation of the concentrations have been made. (author) [es

  10. Determination of total Sb,Se Te, and Bi and evaluation of their inorganic species in garlic by hydride-generation-atomic-fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Matos Reyes, M.N.; Cervera, M.L.; Guardia, M. de la [University of Valencia, Department of Analytical Chemistry, Burjassot, Valencia (Spain)

    2009-07-15

    A sensitive and simple analytical method has been developed for determination of Sb(III), Sb(V), Se(IV), Se(VI), Te(IV), Te(VI), and Bi(III) in garlic samples by using hydride-generation-atomic-fluorescence spectrometry (HG-AFS). The method is based on a single extraction of the inorganic species by sonication at room temperature with 1 mol L{sup -1} H{sub 2}SO{sub 4} and washing of the solid phase with 0.1% (w/v) EDTA, followed by measurement of the corresponding hydrides generated under two different experimental conditions directly and after a pre-reduction step. The limit of detection of the method was 0.7 ng g{sup -1} for Sb(III), 1.0 ng g{sup -1} for Sb(V), 1.3 ng g{sup -1} for Se(IV), 1.0 ng g{sup -1} for Se(VI), 1.1 ng g{sup -1} for Te(IV), 0.5 ng g{sup -1} for Te(VI), and 0.9 ng g{sup -1} for Bi(III), in all cases expressed in terms of sample dry weight. (orig.)

  11. Total Peroxy Nitrates (ΣPNs in the atmosphere: the Thermal Dissociation-Laser Induced Fluorescence (TD-LIF technique and comparisons to speciated PAN measurements

    Directory of Open Access Journals (Sweden)

    B. W. LaFranchi

    2010-05-01

    Full Text Available Peroxyacetyl nitrate (PAN and its chemical analogues are increasingly being quantified in the ambient atmosphere by thermal dissociation (TD followed by detection of either the peroxyacyl radical or the NO2 product. Here we present details of the technique developed at University of California, Berkeley which detects the sum of all peroxynitrates (ΣPNs via laser-induced fluorescence (LIF of the NO2 product. We review the various deployments and compare the Berkeley ΣPNs measurements with the sums of PAN and its homologue species detected individually by other instruments. The observed TD-LIF ΣPNs usually agree to within 10% with the summed individual species, thus arguing against the presence of significant concentrations of unmeasured PAN-type compounds in the atmosphere, as suggested by some photochemical mechanisms. Examples of poorer agreement are attributed to a sampling inlet design that is shown to be inappropriate for high NOx conditions. Interferences to the TD-LIF measurements are described along with strategies to minimize their effects.

  12. Dimensional metrology of lab-on-a-chip internal structures: a comparison of optical coherence tomography with confocal fluorescence microscopy.

    Science.gov (United States)

    Reyes, D R; Halter, M; Hwang, J

    2015-07-01

    The characterization of internal structures in a polymeric microfluidic device, especially of a final product, will require a different set of optical metrology tools than those traditionally used for microelectronic devices. We demonstrate that optical coherence tomography (OCT) imaging is a promising technique to characterize the internal structures of poly(methyl methacrylate) devices where the subsurface structures often cannot be imaged by conventional wide field optical microscopy. The structural details of channels in the devices were imaged with OCT and analyzed with an in-house written ImageJ macro in an effort to identify the structural details of the channel. The dimensional values obtained with OCT were compared with laser-scanning confocal microscopy images of channels filled with a fluorophore solution. Attempts were also made using confocal reflectance and interferometry microscopy to measure the channel dimensions, but artefacts present in the images precluded quantitative analysis. OCT provided the most accurate estimates for the channel height based on an analysis of optical micrographs obtained after destructively slicing the channel with a microtome. OCT may be a promising technique for the future of three-dimensional metrology of critical internal structures in lab-on-a-chip devices because scans can be performed rapidly and noninvasively prior to their use. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  13. Biobased, Internally pH-Sensitive Materials: Immobilized Yellow Fluorescent Protein as an Optical Sensor for Spatiotemporal Mapping of pH Inside Porous Matrices.

    Science.gov (United States)

    Consolati, Tanja; Bolivar, Juan M; Petrasek, Zdenek; Berenguer, Jose; Hidalgo, Aurelio; Guisán, Jose M; Nidetzky, Bernd

    2018-02-28

    The pH is fundamental to biological function and its measurement therefore crucial across all biosciences. Unlike homogenous bulk solution, solids often feature internal pH gradients due to partition effects and confined biochemical reactions. Thus, a full spatiotemporal mapping for pH characterization in solid materials with biological systems embedded in them is essential. In here, therefore, a fully biocompatible methodology for real-time optical sensing of pH within porous materials is presented. A genetically encoded ratiometric pH sensor, the enhanced superfolder yellow fluorescent protein (sYFP), is used to functionalize the internal surface of different materials, including natural and synthetic organic polymers as well as silica frameworks. By using controlled, tailor-made immobilization, sYFP is homogenously distributed within these materials and so enables, via self-referenced imaging analysis, pH measurements in high accuracy and with useful spatiotemporal resolution. Evolution of internal pH is monitored in consequence of a proton-releasing enzymatic reaction, the hydrolysis of penicillin by a penicillin acylase, taking place in solution or confined to the solid surface of the porous matrix. Unlike optochemical pH sensors, which often interfere with biological function, labeling with sYFP enables pH sensing without altering the immobilized enzyme's properties in any of the materials used. Fast response of sYFP to pH change permits evaluation of biochemical kinetics within the solid materials. Thus, pH sensing based on immobilized sYFP represents a broadly applicable technique to the study of biology confined to the internally heterogeneous environment of solid matrices.

  14. Fluorescence spectroscopy

    DEFF Research Database (Denmark)

    Bagatolli, Luis

    2016-01-01

    Fluorescence spectroscopy is a powerful experimental tool used by scientists from many disciplines. During the last decades there have been important developments on distinct fluorescence methods, particularly those related to the study of biological phenomena. This chapter discusses the foundati......Fluorescence spectroscopy is a powerful experimental tool used by scientists from many disciplines. During the last decades there have been important developments on distinct fluorescence methods, particularly those related to the study of biological phenomena. This chapter discusses...

  15. Benefit Comparison of Captioned Online Courses for American, International, and Deaf/Hard of Hearing Students: From the Viewpoint of Individual Value and Total Value

    Directory of Open Access Journals (Sweden)

    Manako Yabe

    2015-05-01

    Full Text Available This study evaluated benefits toward Captioned Online Courses (COC among American, International, and Deaf/Hard of Hearing students from two California universities.  As a result, COC were not just viewed as accommodations for DHH students, but also as providing benefits for American and International students.  Study results indicated that international students showed higher individual value for COC than the other groups, while American students had the smallest individual value but presented the larger total value toward COC than the other groups due to their comprising the largest population at both universities.  The aggregate total value for all groups was approximately $2,000,000.00, which would represent the cost of conducting 370 classes at the lowest price of $2.00 per minute.  These results indicate the possibility of expanding future COC as Universal Design model for postsecondary educational institutions.

  16. Protein-stabilized fluorescent nanocrystals consisting of a gold core and a silver shell for detecting the total amount of cysteine and homocysteine

    International Nuclear Information System (INIS)

    Gui, Rijun; Wang, Yanfeng; Sun, Jie

    2014-01-01

    We report on a simple and sensitive method for the determination of the total amount of cysteine (Cys) and homocysteine (hCys), [Cys plus hCys], by exploiting the effect of Cys and hCys on the photoluminescence of human serum albumin-stabilized gold-core silver-shell nanocrystals (NCs). If Cys (or hCys) are added to these NCs, Cys (or hCys) will be adsorbed on the surface due to ligand exchange with human serum albumin, and this results in the quenching of the luminescence of the NCs. The addition of mixtures of Cys and hCys in different molar ratios also induces a decrease in luminescence whose intensity is linearly related to the concentration of [Cys plus hCys] in the range from 0.1 – 5.0 μM, with a correlation coefficient (R 2 ) of 0.9953 and a detection limit of 15 nM. The method is highly selective and sensitive over other α-amino acids, water-soluble thiols, and biomolecules. It has been successfully applied to the determination of the concentration of [Cys plus hCys] in spiked solutions of biomolecules and in real biological samples (author)

  17. A hybrid total internal reflection fluorescence and optical tweezers microscope to study cell adhesion and membrane protein dynamics of single living cells

    NARCIS (Netherlands)

    Snijder-van As, M.I.; Rieger, B.; Joosten, B.; Subramaniam, Vinod; Figdor, Carl; Kanger, Johannes S.

    2009-01-01

    The dynamics of cell surface membrane proteins plays an important role in cell–cell interactions. The onset of the interaction is typically not precisely controlled by current techniques, making especially difficult the visualization of early-stage dynamics. We have developed a novel method where

  18. Increase in Total Joint Arthroplasty Projected from 2014 to 2046 in Australia: A Conservative Local Model With International Implications.

    Science.gov (United States)

    Inacio, Maria C S; Graves, Stephen E; Pratt, Nicole L; Roughead, Elizabeth E; Nemes, Szilard

    2017-08-01

    The incidence of joint arthroplasty is increasing worldwide. International estimates of future demand for joint arthroplasty have used models that propose either an exponential future increase, despite obvious system constraints, or static increases, which do not account for past trends. Country-specific projection estimates that address limitations of past projections are necessary. In Australia, a high-income country with the 7th highest incidence of TKA and 15th highest incidence of THA of the Organization for Economic Cooperation and Development (OECD) countries, the volume of TKAs and THAs increased 198% between 1994 and 2014. To determine the projected incidence and volume of primary TKAs and THAs from 2014 to 2046 in the Australian population older than 40 years. Australian State and Territory Health Department data were used to identify TKAs and THAs performed between 1994 and 1995 and 2013 and 2014. The Australian Bureau of Statistics was the source of the population estimates for the same periods and population-projected estimates until 2046. The incidence rate (IR), 95% CI, and prediction interval (PI) of TKAs and THAs per 100,000 Australian citizens older than 40 years were calculated. Future IRs were estimated using a logistic model, and volume was calculated from projected IR and population. The logistic growth model assumes the existence of an upper limit of the TKA and THA incidences and a growth rate directly related to this incidence. At the beginning, when the observed incidence is much lower than the asymptote, the increase is exponential, but it decreases as it approaches the upper limit. A 66% increase in the IR of primary THAs between 2013 and 2046 is projected for Australia (2013: IR = 307 per 100,000, [95% CI, 262-329 per 100,000] compared with 2046: IR= 510 per 100,000, [95% PI, 98-567 per 100,000]), which translates to a 219% increase in the volume during this period. For TKAs the IR is expected to increase by 26% by 2046 (IR = 575 per

  19. Internal and External Intertextuality as a ‘Total Novel’ Formula in Noaptea de Sânziene by Mircea Eliade

    Directory of Open Access Journals (Sweden)

    Mihaela RUSU

    2014-12-01

    Full Text Available One of the possible grids of analysis of Mircea Eliade’s novel Noaptea de Sânziene (The Forbidden Forest is intertextuality, which aims at tracing the presence of a text within another text, in view of relating the author’s creativity and the reader’s vigilance. The fictional world of the novel in focus provides the reader with the image of a few intellectual characters which live their personal experience through the fundamental myths of the European space (Ulysses, Percival, Tristan and Isolde, feeling that the modern man relives the experiences of the mythical one. The quotation of a few lines from Dante’s Inferno comes to reinforce the idea that the protagonists are in search for identity in the maze of their lives, seen as an archetype of the world. War, death, and the world’s decay, which take place under their eyes, are expressed using the principles of Hindu philosophy: the world goes through a sombre age named kali-yuga, a form of dissolution which is a requisite for its (recreation. This mixture of direct references to representative European literary works and allusions to Hindu philosophy supports Eliade’s efforts in creating the first total novel in Romanian literature, a work which provides the informed reader with a journey through literary spaces.

  20. Total Lesion Glycolysis and Sequential (90)Y-Selective Internal Radiation Therapy in Breast Cancer Liver Metastases: Preliminary Results.

    Science.gov (United States)

    Bagni, Oreste; Filippi, Luca; Pelle, Giuseppe; Cianni, Roberto; Schillaci, Orazio

    2015-12-01

    To assess the prognostic role of total lesion glycolysis (TLG) in patients with breast cancer liver metastases (BCLM) after sequential lobar (90)Y-radioembolization ((90)Y-RE). Seventeen patients with bilobar BCLM underwent FDG PET/CT and TLG calculation before (90)Y-RE. The hepatic lobe with the highest TLG was treated in the first session. PET was performed 6 weeks postprocedure and decrease in TLG (ΔTLG) in the treated lobe was calculated before the second (90)Y administration. Subjects were divided in two groups (group 1: ΔTLG >50%, group 2: ΔTLG 50% and seven had a ΔTLG value 50% and ΔTLG <50% had a mean OS of 16.4 ± 0.6 and 10.3 ± 0.4 months, respectively (p < 0.001). Cox regression analysis demonstrated hepatic tumor load (p = 0.048) and ΔTLG as the only significant (p = 0.005) predictors of survival. ΔTLG after the first (90)Y administration agrees with final outcome in BCLM patients after separate sequential lobar (90)Y-RE.

  1. Determination of Cr, Mn, Fe, Co, Ni, Cu, Zn and As in the Rimac River waters by x-ray fluorescence in total reflection; Determinacion de Cr, Mn, Fe, Co, Ni, Cu, Zn y As en aguas del Rio Rimac por fluorescencia de rayos-x en reflexion total

    Energy Technology Data Exchange (ETDEWEB)

    Tiznado, W [Universidad Nacional Federico Villarreal, Lima (Peru). Facultad de Ciencias Naturales y Matematicas, EP Quimica; Olivera, P [Instituto Peruano de Energia Nuclear, Lima (Peru). Departamento de Quimica

    2002-07-01

    Samples from thirteen stations of the Rimac River has been analyzed. Samples were performed during one-year-period (september 1998-august 1999), with a frequency of one sample per month. The X-ray fluorescence analysis in total reflection technique has been used in order to determine the Cr, Mn, Fe, Co, Ni, Cu, Zn and As elements on its dissolved phase. The results obtained show: relation of the presence of mining stations with the metal concentration level, specially in the Zn and Fe; As is present in concentrations above those of permissible maximum levels in some of the sampled stations; moreover, Ni and Cr, toxic elements, are found in very low concentrations. On the other hand, it has been proved that the analysis method used is useful as a monitoring tool of superficial water-quality due to its low detection limits and because of the fastness the analysis are made.

  2. Certification of a reference material for determination of total cyanide in soil to support implementation of the International Standard ISO 11262:2011.

    Science.gov (United States)

    Scharf, Holger; Bremser, Wolfram

    2015-04-01

    Cyanides are among the most important inorganic pollutants to be tested and monitored in environmental compartments. They can be distinguished and determined as free cyanide, weak acid dissociable cyanide or as total cyanide. However, in any case obtained, measurement results are operationally defined referring to the applied analytical method. In 2011, the International Standard ISO 11262 has been published which specifies a normative analytical method for the determination of total cyanide in soil. The objective of the project described in this paper was to provide the first soil reference material (CRM) certified for its mass fraction of total cyanide on the basis of this standard. A total of 12 German laboratories with proven experience in the determination of cyanides in environmental samples participated in the certification study. Measurement results were evaluated in full compliance with the requirements of ISO Guide 35. Taking into account the results of the inter-laboratory comparison as well as the outcome of the homogeneity and stability studies, a certified mass fraction of total cyanide of 21.1 mg/kg and an expanded uncertainty (k = 2) of 1.3 mg/kg were assigned to the material. The reference material has been issued as CRM BAM-U114.

  3. An assessment of the importance ofexposure routes to the uptake and internal localisation of fluorescent nanoparticles in zebrafish (Danio rerio), using light sheet microscopy

    DEFF Research Database (Denmark)

    Skjolding, Lars Michael; Ašmonaitė, G; Jølck, Rasmus Irming

    2017-01-01

    A major challenge in nanoecotoxicology is finding suitable methods to determine the uptake and localisation of nanoparticles on a whole-organism level. Some uptake methods have been associated with artefacts induced by sample preparation, including staining for electron microscopy. This study used...... light sheet microscopy (LSM) to define the uptake and localisation of fluorescently labelled nanoparticles in living organisms with minimal sample preparation. Zebrafish (Danio rerio) were exposed to fluorescent gold nanoparticles (Au NPs) and fluorescent polystyrene NPs via aqueous or dietary exposure...

  4. Evaluation of water and sediment of the Graminha and Aguas da Serra streams in the city of Limeira (Sp-Brazil) by Synchrotron Radiation Total Reflection X-ray Fluorescence

    International Nuclear Information System (INIS)

    Moreira, Silvana; Fazza, Elizete Vieira

    2008-01-01

    The city of Limeira is located in the state of Sao Paulo, Brazil and has the second largest economy and demographic growth of the state. It comprises an expressive economy with industries in several productive sectors. The source of the Graminha and Aguas da Serra streams is located within the Limeira urban zone. The streams cross part of the rural zone and unite by draining into the Piracicaba River. It is possible that these basins suffer or have already suffered the impacts of environmental pollution caused by anthropogenic factors. Since the city has galvanization industries for the production of precious and semi-precious jewels as well as imitation jewelry, the concentration descriptions and interpretations of heavy metals in waters and sediments indicate anthropogenic influence and the dumping of these compounds into the Piracicaba River. The Synchrotron Radiation Total Reflection X-Ray Fluorescence (SR-TXRF) was used for determining the metals. All measurements were performed using a white beam of synchrotron radiation for excitation and a Ge hyperpure detector. Detection limits for water samples were 0.04 μg L -1 and in sediment samples 0.03 μg g -1 for Cu and Zn elements. In the water samples, concentrations higher than permissible as established by the Brazilian legislation (CONAMA) for Al, Fe, Zn, Cr, Ni, Cu and Pb, were observed. For sediment samples, values higher than quality reference values defined by the Brazilian legislation (CETESB) were verified for Cr, Zn, Cu, Ni and Pb

  5. A new vapor generation system for mercury species based on the UV irradiation of mercaptoethanol used in the determination of total and methyl mercury in environmental and biological samples by atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Yanmin; Qiu, Jianhua; Yang, Limin [College of Chemistry and Chemical Engineering, Xiamen University, Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, Xiamen (China); Wang, Qiuquan [College of Chemistry and Chemical Engineering, Xiamen University, Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, Xiamen (China); Xiamen University, State Key Laboratory of Marine Environmental Science, Xiamen (China)

    2007-06-15

    A new vapor generation system for mercury (Hg) species based on the irradiation of mercaptoethanol (ME) with UV was developed to provide an effective sample introduction unit for atomic fluorescence spectrometry (AFS). Preliminary investigations of the mechanism of this novel vapor generation system were based on GC-MS and FT-IR studies. Under optimum conditions, the limits of determination for inorganic divalence mercury and methyl mercury were 60 and 50 pg mL{sup -1}, respectively. Certified reference materials (BCR 463 tuna fish and BCR 580 estuarine sediment) were used to validate this new method, and the results agreed well with certified values. This new system provides an attractive alternative method of chemical vapor generation (CVG) of mercury species compared to other developed CVG systems (for example, the traditional KBH{sub 4}/NaOH-acid system). To our knowledge, this is the first systematic report on UV/ME-based Hg species vapor generation and the determination of total and methyl Hg in environmental and biological samples using UV/ME-AFS. (orig.)

  6. Evaluation of water and sediment of the Graminha and Aguas da Serra streams in the city of Limeira (Sp-Brazil) by Synchrotron Radiation Total Reflection X-ray Fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [University of Campinas, School of Civil Engineering, Architecture and Urban Design, P. O. Box 602, Zip Code 13083-852, Campinas, SP (Brazil)], E-mail: silvana@fec.unicamp.br; Fazza, Elizete Vieira [University of Campinas, School of Civil Engineering, Architecture and Urban Design, P. O. Box 602, Zip Code 13083-852, Campinas, SP (Brazil)], E-mail: fazzaelizete@yahoo.com

    2008-12-15

    The city of Limeira is located in the state of Sao Paulo, Brazil and has the second largest economy and demographic growth of the state. It comprises an expressive economy with industries in several productive sectors. The source of the Graminha and Aguas da Serra streams is located within the Limeira urban zone. The streams cross part of the rural zone and unite by draining into the Piracicaba River. It is possible that these basins suffer or have already suffered the impacts of environmental pollution caused by anthropogenic factors. Since the city has galvanization industries for the production of precious and semi-precious jewels as well as imitation jewelry, the concentration descriptions and interpretations of heavy metals in waters and sediments indicate anthropogenic influence and the dumping of these compounds into the Piracicaba River. The Synchrotron Radiation Total Reflection X-Ray Fluorescence (SR-TXRF) was used for determining the metals. All measurements were performed using a white beam of synchrotron radiation for excitation and a Ge hyperpure detector. Detection limits for water samples were 0.04 {mu}g L{sup -1} and in sediment samples 0.03 {mu}g g{sup -1} for Cu and Zn elements. In the water samples, concentrations higher than permissible as established by the Brazilian legislation (CONAMA) for Al, Fe, Zn, Cr, Ni, Cu and Pb, were observed. For sediment samples, values higher than quality reference values defined by the Brazilian legislation (CETESB) were verified for Cr, Zn, Cu, Ni and Pb.

  7. Analysis of trace and mineral elements in vanilla pods from the region of S.A.V.A using total reflection X-ray fluorescence, atomic absorption and ion chromatography techniques

    International Nuclear Information System (INIS)

    Be, K.

    2013-01-01

    In the case of studies of food security, - arsenic, cobalt, chromium, copper, iron, manganese, nickel, rubidium, selenium, strontium, titanium, zinc - cadmium, lead - are almost always analyzed. Guide values are used to express the level of quality in matter of consumption. Analytical laboratories of Madagascar-INSTN outline usually their research on quantifying those elements by using two different analytical methods, the Total Reflection X-Ray Fluorescence for the first twelve metals and the Atomic Absorption Spectrometry dedicated to lead and cadmium. Supplementary analysis is carried out for the quantification of essential mineral elements such as calcium, magnesium and potassium by using Ion Chromatograph. The aim of this study was to set up the analysis of the above mentioned elements in vanilla pods collected from Sambava, Antalaha and Andapa for a routine use. After all the parameters were established, the validation was particularly focused on the limits of detection and quantification and the accuracy of each element. The used methods fulfil the scope of application needed and are easy to use in routine. [fr

  8. A new technique for the deposition of standard solutions in total reflection X-ray fluorescence spectrometry (TXRF) using pico-droplets generated by inkjet printers and its applicability for aerosol analysis with SR-TXRF

    International Nuclear Information System (INIS)

    Fittschen, U.E.A.; Hauschild, S.; Amberger, M.A.; Lammel, G.; Streli, C.; Foerster, S.; Wobrauschek, P.; Jokubonis, C.; Pepponi, G.; Falkenberg, G.; Broekaert, J.A.C.

    2006-01-01

    A new technique for the deposition of standard solutions on particulate aerosol samples using pico-droplets for elemental determinations with total reflection X-ray fluorescence spectrometry (TXRF) is described. It enables short analysis times without influencing the sample structure and avoids time consuming scanning of the sample with the exciting beam in SR-TXRF analysis. Droplets of picoliter volume (∼ 5-130 pL) were generated with commercially available and slightly modified inkjet printers operated with popular image processing software. The size of the dried droplets on surfaces of different polarity namely silicone coated and untreated quartz reflectors, was determined for five different printer types and ten different cartridge types. The results show that droplets generated by inkjet printers are between 50 and 200 μm in diameter (corresponding to volumes of 5 to 130 pL) depending on the cartridge type, which is smaller than the width of the synchrotron beam used in the experiments (< 1 mm at an energy of 17 keV at the beamline L at HASYLAB, Hamburg). The precision of the printing of a certain amount of a single element standard solution was found to be comparable to aliquoting with micropipettes in TXRF, where for 2.5 ng of cobalt relative standard deviations of 12% are found. However, it could be shown that the printing of simple patterns is possible, which is important when structured samples have to be analysed

  9. Optical interrupter based in the internal total reflection of spatial solitons at nonlinear saturable interfaces; Interruptores opticos basados en reflexion interna total de solitones espaciales en interfaces no lineales saturables

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado-Mendez, E.; Torres-Cisneros, M.; Gutierrez-Hernandez, D. A.; Andrade-Lucio, J. A.; Rojas-Lagunas, R.; Pedraza-Ortega, J. C.; Torres Cisneros, G. E. [Universidad de Guanajuato, Guanajuato (Mexico); Sanchez Mondragon, J. J. [Universidad Autonoma del Estado de Morelos, Morelos (Mexico); Flores-Alvarado, G. [Preparatoria por Cooperacion Domingo Arenas, Tlaxcala (Mexico)

    2001-06-01

    We study the reflection of one-dimensional spatial soliton at the nonlinear interface between a saturable type medium and linear medium. Our study makes emphasis on determining the physical conditions under which the beam reflected by the interface is still a spatial soliton. Depended the incidence angle we find three critical regions for spatial solitons in the interface. We observed nonlinear Goos- Haechen shift is determined if reflection angle are conserved. Finally, we present preliminary experimental results in SBN61:Ce of the total internal reflection of one dimensional beam. [Spanish] Estudiamos la reflexion de un soliton espacial unidimensional en una interfase formada por un medio no lineal saturable y un medio lineal. Nuestros estudios hacen enfasis en determinar las condiciones fisicas bajo las cuales el haz reflejado por la interfase no lineal sigue siendo soliton. Encontramos tres regiones criticas para un soliton especial en la interfase, dependiendo del valor que tome el angulo de incidencia. Asi mismo observamos corrimiento Goos-Haechen no lineal que es determinante para la conservacion del angulo de reflexion. Finalmente, presentamos resultados preliminares experimentales en SBN61:Ce de la reflexion interna total de un haz unidimensional.

  10. Use of total internal reflection Raman (TIR) and attenuated total reflection infrared (ATR-IR) spectroscopy to analyze component separation in thin offset ink films after setting on coated paper surfaces.

    Science.gov (United States)

    Kivioja, Antti; Hartus, Timo; Vuorinen, Tapani; Gane, Patrick; Jääskeläinen, Anna-Stiina

    2013-06-01

    The interactive behavior of ink constituents with porous substrates during and after the offset print process has an important effect on the quality of printed products. To help elucidate the distribution of ink components between the retained ink layer and the substrate, a variety of spectroscopic and microscopic analysis techniques have been developed. This paper describes for the first time the use of total internal reflection (TIR) Raman spectroscopy to analyze the penetration behavior of separated offset ink components (linseed oil, solid color pigment) in coated papers providing chemically intrinsic information rapidly, nondestructively, and with minimal sample preparation. In addition, the already widely applied technique of attenuated total reflection infrared spectroscopy (ATR-IR) was evaluated in parallel and compared. The results of the ATR-IR Raman clearly revealed an improvement in uppermost depth resolution compared with values previously published from other nondestructive techniques, and the method is shown to be capable of providing new knowledge of the setting of thin (0.25-2 μm) offset ink films, allowing the spreading and the penetration behavior on physically different paper coating surfaces to be studied.

  11. The influence of the solid waste disposal areas in Campinas city, Sao Paulo state (Brazil) on water quality: determination of metals using synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Oliveira, Bruna F.F.; Moreira, Silvana; Canteras, Felippe Benavente

    2013-01-01

    Among the many forms of waste disposal, landfills today are best suited to Brazilian conditions, this because their construction allows minimizing the negative effects of landfill gas and slurry produced. However, the confinement of pollutants from landfills is linked to its construction and operation and when the construction and/or is wrong they can endanger air, groundwater and surface waters qualities. Thus, the main objective of this study was to analyze the concentration of heavy metals in samples of groundwater, surface water and slurry coming from solid waste disposal locations in the city of Campinas, SP - Delta, Santa Barbara and Pirelli Landfills. The samples were analyzed at the Brazilian Synchrotron Light Laboratory using Synchrotron Radiation Total Reflection X-Ray Fluorescence technique (SR-TXRF). In Pirelli Landfill, the highest concentrations were observed in one of the wells located to downstream of the Landfill (in relation to the groundwater flux) - the monitoring well PM04, exceeding the intervention value defined by CETESB. For Santa Barbara landfill in one upstream monitoring well the concentrations of Ni, Mn, Pb and Cr, surpassed the maximum permissive values. The manganese in Landfill Delta showed to be higher in wells located downstream and 50% of the wells analyzed exceeded the maximum permissive value for groundwater samples. In the case of surface waters located in the vicinity of landfill sites, the metals that surpassed the maximum permissive values according the legislation in most of the points analyzed were Mn, Cu and Pb. For slurry samples collected in Delta Landfill, the average concentrations for Mn, Ni, Cu and Pb not exceeded the maximum permissive values during the period studied. Moreover for Santa Barbara the average concentration of Mn, Cu and Zn surpassed the permissive limits, as was observed for Mn in the Pirelli Landfill. (author)

  12. Spirally-patterned pinhole arrays for long-term fluorescence cell imaging.

    Science.gov (United States)

    Koo, Bon Ung; Kang, YooNa; Moon, SangJun; Lee, Won Gu

    2015-11-07

    Fluorescence cell imaging using a fluorescence microscope is an extensively used technique to examine the cell nucleus, internal structures, and other cellular molecules with fluorescence response time and intensity. However, it is difficult to perform high resolution cell imaging for a long period of time with this technique due to necrosis and apoptosis depending on the type and subcellular location of the damage caused by phototoxicity. A large number of studies have been performed to resolve this problem, but researchers have struggled to meet the challenge between cellular viability and image resolution. In this study, we employ a specially designed disc to reduce cell damage by controlling total fluorescence exposure time without deterioration of the image resolution. This approach has many advantages such as, the apparatus is simple, cost-effective, and easily integrated into the optical pathway through a conventional fluorescence microscope.

  13. A comparison of the performance of a fundamental parameter method for analysis of total reflection X-ray fluorescence spectra and determination of trace elements, versus an empirical quantification procedure

    Science.gov (United States)

    W(egrzynek, Dariusz; Hołyńska, Barbara; Ostachowicz, Beata

    1998-01-01

    The performance has been compared of two different quantification methods — namely, the commonly used empirical quantification procedure and a fundamental parameter approach — for determination of the mass fractions of elements in particulate-like sample residues on a quartz reflector measured in the total reflection geometry. In the empirical quantification procedure, the spectrometer system needs to be calibrated with the use of samples containing known concentrations of the elements. On the basis of intensities of the X-ray peaks and the known concentration or mass fraction of an internal standard element, by using relative sensitivities of the spectrometer system the concentrations or mass fractions of the elements are calculated. The fundamental parameter approach does not require any calibration of the spectrometer system to be carried out. However, in order to account for an unknown mass per unit area of a sample and sample nonuniformity, an internal standard element is added. The concentrations/mass fractions of the elements to be determined are calculated during fitting a modelled X-ray spectrum to the measured one. The two quantification methods were applied to determine the mass fractions of elements in the cross-sections of a peat core, biological standard reference materials and to determine the concentrations of elements in samples prepared from an aqueous multi-element standard solution.

  14. Development of a valid Simplified Chinese version of the International Hip Outcome Tool (SC-iHOT-33) in young patients having total hip arthroplasty.

    Science.gov (United States)

    Li, D H; Wang, W; Li, X; Gao, Y L; Liu, D H; Liu, D L; Xu, W D

    2017-01-01

    The International Hip Outcome Tool (iHOT-33) is a questionnaire designed for young, active patients with hip disorders. It has proven to be a highly reliable and valid questionnaire. The main purpose of our study was to adapt the iHOT-33 questionnaire into simplified Chinese and to assess its psychometric properties in Chinese patients. The iHOT-33 was cross culturally adapted into Chinese and 138 patients completed the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the EuroQol-5D (EQ-5D), and the Chinese version of the iHOT-33(SC-iHOT-33) pre- or postoperatively within 6 months' follow-up. The Cronbach's alpha, intraclass correlation coefficient (ICC), Pearson's correlation coefficient (r), effect size (ES), and standardized response mean (SRM) were calculated to assess the reliability, validity, and responsiveness of the SC-iHOT-33, respectively. Total Cronbach's alpha was 0.965, which represented excellent internal consistency of the SC-iHOT-33. The ICC ranges from 0.866 to 0.929, which shows excellent test-retest reliability. The subscales of SC-iHOT-33 had the highest correlation coefficient (r = 0.812) with the physical function subscales of the WOMAC, as well as good correlation between the social/emotional subscale of the SC-iHOT-33 and the EQ-5D (r = 0.740, r = 0.743). No floor or ceiling effects were found. The ES and SRM values indicated good responsiveness of 2.44 and 2.67, respectively. The SC-iHOT-33 questionnaire is reliable, valid, and responsive for the evaluation of young, Chinese, active patients with hip disorders. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Total reflection X-ray fluorescence applied to the chemical elements analysis of the mate tea infusion (Ilex-paraguariensis); Fluorescencia de raios-X por reflexao total aplicada a analise de elementos quimicos em cha de erva-mate (Ilex-paraguariensis)

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Fabio; Appoloni, Carlos R. [Universidade Estadual de Londrina, PR (Brazil). Lab. de Fisica Nuclear Aplicada; Cunha, Richard M. da Silva e; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear

    2002-07-01

    The purpose was to evaluate simultaneously the chemical element concentrations from K to Sr (19{<=}Z{<=}38) range in six samples of mate tea (Ilex paraguariensis) infusion, commercially available in Paraguay and South of Brazil. The chemical analysis of this beverage has a great nutritional importance for the native people of these areas, due to their large daily consumption. For the determination of these elements the dry-ashing and total reflection X-rays fluorescence (TXRF) were used. The methodology showed limits of detection among 81 ng.mL-1 for K to 10 ng.mL{sup -1} for Zn. Six infusion samples were prepared in triplicate, and the concentration was 3,8 to 10,2 {mu}g.mL{sup -1} for K, Ca and Mn, 0,21 to 1,07 {mu}g. mL{sup -1} for Fe and Zn and 0.03 to 0,17 {mu}g.mL{sup -1} for Ni, Cu, Br, Rb and Sr. The Mn and Ni concentrations are above the maximum permissible values for drinking water established by World Health Organization and Brazilian legislation (these organisms do not regulate the maximum permissible values for chemical elements in mate tea infusion). (author)

  16. Submicrometre geometrically encoded fluorescent barcodes self-assembled from DNA

    Science.gov (United States)

    Lin, Chenxiang; Jungmann, Ralf; Leifer, Andrew M.; Li, Chao; Levner, Daniel; Church, George M.; Shih, William M.; Yin, Peng

    2012-10-01

    The identification and differentiation of a large number of distinct molecular species with high temporal and spatial resolution is a major challenge in biomedical science. Fluorescence microscopy is a powerful tool, but its multiplexing ability is limited by the number of spectrally distinguishable fluorophores. Here, we used (deoxy)ribonucleic acid (DNA)-origami technology to construct submicrometre nanorods that act as fluorescent barcodes. We demonstrate that spatial control over the positioning of fluorophores on the surface of a stiff DNA nanorod can produce 216 distinct barcodes that can be decoded unambiguously using epifluorescence or total internal reflection fluorescence microscopy. Barcodes with higher spatial information density were demonstrated via the construction of super-resolution barcodes with features spaced by ˜40 nm. One species of the barcodes was used to tag yeast surface receptors, which suggests their potential applications as in situ imaging probes for diverse biomolecular and cellular entities in their native environments.

  17. Enhanced sensitivity to dielectric function and thickness of absorbing thin films by combining total internal reflection ellipsometry with standard ellipsometry and reflectometry

    International Nuclear Information System (INIS)

    Lizana, A; Foldyna, M; Garcia-Caurel, E; Stchakovsky, M; Georges, B; Nicolas, D

    2013-01-01

    High sensitivity of spectroscopic ellipsometry and reflectometry for the characterization of thin films can strongly decrease when layers, typically metals, absorb a significant fraction of the light. In this paper, we propose a solution to overcome this drawback using total internal reflection ellipsometry (TIRE) and exciting a surface longitudinal wave: a plasmon-polariton. As in the attenuated total reflectance technique, TIRE exploits a minimum in the intensity of reflected transversal magnetic (TM) polarized light and enhances the sensitivity of standard methods to thicknesses of absorbing films. Samples under study were stacks of three films, ZnO : Al/Ag/ZnO : Al, deposited on glass substrates. The thickness of the silver layer varied from sample to sample. We performed measurements with a UV–visible phase-modulated ellipsometer, an IR Mueller ellipsometer and a UV–NIR reflectometer. We used the variance–covariance formalism to evaluate the sensitivity of the ellipsometric data to different parameters of the optical model. Results have shown that using TIRE doubled the sensitivity to the silver layer thickness when compared with the standard ellipsometry. Moreover, the thickness of the ZnO : Al layer below the silver layer can be reliably quantified, unlike for the fit of the standard ellipsometry data, which is limited by the absorption of the silver layer. (paper)

  18. Enhanced sensitivity to dielectric function and thickness of absorbing thin films by combining total internal reflection ellipsometry with standard ellipsometry and reflectometry

    Science.gov (United States)

    Lizana, A.; Foldyna, M.; Stchakovsky, M.; Georges, B.; Nicolas, D.; Garcia-Caurel, E.

    2013-03-01

    High sensitivity of spectroscopic ellipsometry and reflectometry for the characterization of thin films can strongly decrease when layers, typically metals, absorb a significant fraction of the light. In this paper, we propose a solution to overcome this drawback using total internal reflection ellipsometry (TIRE) and exciting a surface longitudinal wave: a plasmon-polariton. As in the attenuated total reflectance technique, TIRE exploits a minimum in the intensity of reflected transversal magnetic (TM) polarized light and enhances the sensitivity of standard methods to thicknesses of absorbing films. Samples under study were stacks of three films, ZnO : Al/Ag/ZnO : Al, deposited on glass substrates. The thickness of the silver layer varied from sample to sample. We performed measurements with a UV-visible phase-modulated ellipsometer, an IR Mueller ellipsometer and a UV-NIR reflectometer. We used the variance-covariance formalism to evaluate the sensitivity of the ellipsometric data to different parameters of the optical model. Results have shown that using TIRE doubled the sensitivity to the silver layer thickness when compared with the standard ellipsometry. Moreover, the thickness of the ZnO : Al layer below the silver layer can be reliably quantified, unlike for the fit of the standard ellipsometry data, which is limited by the absorption of the silver layer.

  19. A Starting Point for Fluorescence-Based Single-Molecule Measurements in Biomolecular Research

    Directory of Open Access Journals (Sweden)

    Alexander Gust

    2014-09-01

    Full Text Available Single-molecule fluorescence techniques are ideally suited to provide information about the structure-function-dynamics relationship of a biomolecule as static and dynamic heterogeneity can be easily detected. However, what type of single-molecule fluorescence technique is suited for which kind of biological question and what are the obstacles on the way to a successful single-molecule microscopy experiment? In this review, we provide practical insights into fluorescence-based single-molecule experiments aiming for scientists who wish to take their experiments to the single-molecule level. We especially focus on fluorescence resonance energy transfer (FRET experiments as these are a widely employed tool for the investigation of biomolecular mechanisms. We will guide the reader through the most critical steps that determine the success and quality of diffusion-based confocal and immobilization-based total internal reflection fluorescence microscopy. We discuss the specific chemical and photophysical requirements that make fluorescent dyes suitable for single-molecule fluorescence experiments. Most importantly, we review recently emerged photoprotection systems as well as passivation and immobilization strategies that enable the observation of fluorescently labeled molecules under biocompatible conditions. Moreover, we discuss how the optical single-molecule toolkit has been extended in recent years to capture the physiological complexity of a cell making it even more relevant for biological research.

  20. International

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    This rubric reports on 10 short notes about international economical facts about nuclear power: Electricite de France (EdF) and its assistance and management contracts with Eastern Europe countries (Poland, Hungary, Bulgaria); Transnuclear Inc. company (a 100% Cogema daughter company) acquired the US Vectra Technologies company; the construction of the Khumo nuclear power plant in Northern Korea plays in favour of the reconciliation between Northern and Southern Korea; the delivery of two VVER 1000 Russian reactors to China; the enforcement of the cooperation agreement between Euratom and Argentina; Japan requested for the financing of a Russian fast breeder reactor; Russia has planned to sell a floating barge-type nuclear power plant to Indonesia; the control of the Swedish reactor vessels of Sydkraft AB company committed to Tractebel (Belgium); the renewal of the nuclear cooperation agreement between Swiss and USA; the call for bids from the Turkish TEAS electric power company for the building of the Akkuyu nuclear power plant answered by three candidates: Atomic Energy of Canada Limited (AECL), Westinghouse (US) and the French-German NPI company. (J.S.)

  1. Quantitative analysis of active compounds in pharmaceutical preparations by use of attenuated total-reflection Fourier transform mid-infrared spectrophotometry and the internal standard method.

    Science.gov (United States)

    Sastre Toraño, J; van Hattum, S H

    2001-10-01

    A new method is presented for the quantitative analysis of compounds in pharmaceutical preparations Fourier transform (FT) mid-infrared (MIR) spectroscopy with an attenuated total reflection (ATR) module. Reduction of the quantity of overlapping absorption bands, by interaction of the compound of interest with an appropriate solvent, and the employment of an internal standard (IS), makes MIR suitable for quantitative analysis. Vigabatrin, as active compound in vigabatrin 100-mg capsules, was used as a model compound for the development of the method. Vigabatrin was extracted from the capsule content with water after addition of a sodium thiosulfate IS solution. The extract was concentrated by volume reduction and applied to the FTMIR-ATR module. Concentrations of unknown samples were calculated from the ratio of the vigabatrin band area (1321-1610 cm(-1)) and the IS band area (883-1215 cm(-1)) using a calibration standard. The ratio of the area of the vigabatrin peak to that of the IS was linear with the concentration in the range of interest (90-110 mg, in twofold; n=2). The accuracy of the method in this range was 99.7-100.5% (n=5) with a variability of 0.4-1.3% (n=5). The comparison of the presented method with an HPLC assay showed similar results; the analysis of five vigabatrin 100-mg capsules resulted in a mean concentration of 102 mg with a variation of 2% with both methods.

  2. Near-Membrane Refractometry Using Supercritical Angle Fluorescence.

    Science.gov (United States)

    Brunstein, Maia; Roy, Lopamudra; Oheim, Martin

    2017-05-09

    Total internal reflection fluorescence (TIRF) microscopy and its variants are key technologies for visualizing the dynamics of single molecules or organelles in live cells. Yet truly quantitative TIRF remains problematic. One unknown hampering the interpretation of evanescent-wave excited fluorescence intensities is the undetermined cell refractive index (RI). Here, we use a combination of TIRF excitation and supercritical angle fluorescence emission detection to directly measure the average RI in the "footprint" region of the cell during image acquisition. Our RI measurement is based on the determination on a back-focal plane image of the critical angle separating evanescent and far-field fluorescence emission components. We validate our method by imaging mouse embryonic fibroblasts and BON cells. By targeting various dyes and fluorescent-protein chimeras to vesicles, the plasma membrane, as well as mitochondria and the endoplasmic reticulum, we demonstrate local RI measurements with subcellular resolution on a standard TIRF microscope, with a removable Bertrand lens as the only modification. Our technique has important applications for imaging axial vesicle dynamics and the mitochondrial energy state or detecting metabolically more active cancer cells. Copyright © 2017. Published by Elsevier Inc.

  3. Internal-external malalignment of the femoral component in kinematically aligned total knee arthroplasty increases tibial force imbalance but does not change laxities of the tibiofemoral joint.

    Science.gov (United States)

    Riley, Jeremy; Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2018-06-01

    The purposes of this study were to quantify the increase in tibial force imbalance (i.e. magnitude of difference between medial and lateral tibial forces) and changes in laxities caused by  2° and 4° of internal-external (I-E) malalignment of the femoral component in kinematically aligned total knee arthroplasty. Because I-E malalignment would introduce the greatest changes to the articular surfaces near 90° of flexion, the hypotheses were that the tibial force imbalance would be significantly increased near 90° flexion and that primarily varus-valgus laxity would be affected near 90° flexion. Kinematically aligned TKA was performed on ten human cadaveric knee specimens using disposable manual instruments without soft tissue release. One 3D-printed reference femoral component, with unmodified geometry, was aligned to restore the native distal and posterior femoral joint lines. Four 3D-printed femoral components, with modified geometry, introduced I-E malalignments of 2° and 4° from the reference component. Medial and lateral tibial forces were measured from 0° to 120° flexion using a custom tibial force sensor. Bidirectional laxities in four degrees of freedom were measured from 0° to 120° flexion using a custom load application system. Tibial force imbalance increased the greatest at 60° flexion where a regression analysis against the degree of I-E malalignment yielded sensitivities (i.e. slopes) of 30 N/° (medial tibial force > lateral tibial force) and 10 N/° (lateral tibial force > medial tibial force) for internal and external malalignments, respectively. Valgus laxity increased significantly with the 4° external component with the greatest increase of 1.5° occurring at 90° flexion (p < 0.0001). With the tibial component correctly aligned, I-E malalignment of the femoral component caused significant increases in tibial force imbalance. Minimizing I-E malalignment lowers the increase in the tibial force imbalance. By keeping

  4. Influence of the internalization pathway on the efficacy of siRNA delivery by cationic fluorescent nanodiamonds in the Ewing sarcoma cell model.

    Directory of Open Access Journals (Sweden)

    Anna Alhaddad

    Full Text Available Small interfering RNAs (siRNAs are powerful tools commonly used for the specific inhibition of gene expression. However, vectorization is required to facilitate cell penetration and to prevent siRNA degradation by nucleases. We have shown that diamond nanocrystals coated with cationic polymer can be used to carry siRNAs into Ewing sarcoma cells, in which they remain traceable over long periods, due to their intrinsic stable fluorescence. We tested two cationic polymers, polyallylamine and polyethylenimine. The release of siRNA, accompanied by Ewing sarcoma EWS-Fli1 oncogene silencing, was observed only with polyethylenimine. We investigated cell penetration and found that the underlying mechanisms accounted for these differences in behavior. Using drugs selectively inhibiting particular pathways and a combination of fluorescence and electronic microscopy, we showed that siRNA gene silencing occurred only if the siRNA:cationic nanodiamond complex followed the macropinocytosis route. These results have potential implications for the design of efficient drug-delivery vectors.

  5. Influence of the Internalization Pathway on the Efficacy of siRNA Delivery by Cationic Fluorescent Nanodiamonds in the Ewing Sarcoma Cell Model

    Science.gov (United States)

    Alhaddad, Anna; Durieu, Catherine; Dantelle, Géraldine; Le Cam, Eric; Malvy, Claude; Treussart, François; Bertrand, Jean-Rémi

    2012-01-01

    Small interfering RNAs (siRNAs) are powerful tools commonly used for the specific inhibition of gene expression. However, vectorization is required to facilitate cell penetration and to prevent siRNA degradation by nucleases. We have shown that diamond nanocrystals coated with cationic polymer can be used to carry siRNAs into Ewing sarcoma cells, in which they remain traceable over long periods, due to their intrinsic stable fluorescence. We tested two cationic polymers, polyallylamine and polyethylenimine. The release of siRNA, accompanied by Ewing sarcoma EWS-Fli1 oncogene silencing, was observed only with polyethylenimine. We investigated cell penetration and found that the underlying mechanisms accounted for these differences in behavior. Using drugs selectively inhibiting particular pathways and a combination of fluorescence and electronic microscopy, we showed that siRNA gene silencing occurred only if the siRNA:cationic nanodiamond complex followed the macropinocytosis route. These results have potential implications for the design of efficient drug-delivery vectors. PMID:23284935

  6. Influence of the internalization pathway on the efficacy of siRNA delivery by cationic fluorescent nanodiamonds in the Ewing sarcoma cell model.

    Science.gov (United States)

    Alhaddad, Anna; Durieu, Catherine; Dantelle, Géraldine; Le Cam, Eric; Malvy, Claude; Treussart, François; Bertrand, Jean-Rémi

    2012-01-01

    Small interfering RNAs (siRNAs) are powerful tools commonly used for the specific inhibition of gene expression. However, vectorization is required to facilitate cell penetration and to prevent siRNA degradation by nucleases. We have shown that diamond nanocrystals coated with cationic polymer can be used to carry siRNAs into Ewing sarcoma cells, in which they remain traceable over long periods, due to their intrinsic stable fluorescence. We tested two cationic polymers, polyallylamine and polyethylenimine. The release of siRNA, accompanied by Ewing sarcoma EWS-Fli1 oncogene silencing, was observed only with polyethylenimine. We investigated cell penetration and found that the underlying mechanisms accounted for these differences in behavior. Using drugs selectively inhibiting particular pathways and a combination of fluorescence and electronic microscopy, we showed that siRNA gene silencing occurred only if the siRNA:cationic nanodiamond complex followed the macropinocytosis route. These results have potential implications for the design of efficient drug-delivery vectors.

  7. Adsorption of benzyldimethylhexadecylammonium chloride at the hydrophobic silica-water interface studied by total internal reflection Raman spectroscopy: effects of silica surface properties and metal salt addition.

    Science.gov (United States)

    Grenoble, Zlata; Baldelli, Steven

    2013-08-29

    The adsorption of the cationic surfactant benzyldimethylhexadecylammonium (BDMHA(+)) chloride was studied at an octadecyltrichlorosilane (OTS)-monolayer-modified silica-water interface by Raman spectroscopy in total internal reflection (TIR) geometry. The present study demonstrates the capabilities of this spectroscopic technique to evaluate thermodynamic and kinetic BDMHA(+)Cl(-) adsorption properties at the hydrophobic silica surface. The surface coverage of BDMHA(+) decreased by 50% at the hydrophobic OTS-silica surface relative to the surface coverage on bare silica; the dominating driving mechanisms for surfactant adsorption were identified as hydrophobic effects and head group charge screening by the electrolyte counterions. Addition of magnesium metal salt (MgCl2) to the aqueous solution (∼ neutral pH) lowered the surface coverage and moderately increased the Langmuir adsorption constants relative to those of the pure surfactant. These trends were previously observed at the hydrophilic, negatively charged silica surface but with a smaller change in the Gibbs free energy of adsorption at the hydrophobic silica surface. The hydrophobic OTS-silica surface properties resulted in shorter times for the surfactant to reach steady-state adsorption conditions compared to the slow adsorption kinetics previously seen with the surfactant at the hydrophilic surface. Adsorption isotherms, based on Raman signal intensities from spectral analysis, were developed according to the Langmuir adsorption model for the pure surfactant at the OTS-silica-water interface; the modified Langmuir model was applied to the surfactant adsorption in the presence of 5, 10, 50, and 100 mM magnesium chloride. Spectral analysis of the Raman scattering intensities and geometric considerations suggests a hemimicelle-type surface aggregate as the most likely surfactant structure at the OTS-silica surface. The different kinetics observed at the hydrophilic versus the hydrophobic silica surface

  8. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  9. Connoted hazard and perceived importance of fluorescent, neon, and standard safety colors.

    Science.gov (United States)

    Zielinska, O A; Mayhorn, C B; Wogalter, M S

    2017-11-01

    The perceived hazard and rated importance of standard safety, fluorescent, and neon colors are investigated. Colors are used in warnings to enhance hazard communication. Red has consistently been rated as the highest in perceived hazard. Orange, yellow, and black are the next highest in connoted hazard; however, there is discrepancy in their ordering. Safety standards, such as ANSI Z535.1, also list colors to convey important information, but little research has examined the perceived importance of colors. In addition to standard safety colors, fluorescent colors are more commonly used in warnings. Understanding hazard and importance perceptions of standard safety and fluorescent colors is necessary to create effective warnings. Ninety participants rated and ranked a total of 33 colors on both perceived hazard and perceived importance. Rated highest were the safety red colors from the American National Standard Institute (ANSI), International Organization for Standardization (ISO), and Federal Highway Administration (FHWA) together with three fluorescent colors (orange, yellow, and yellow-green) from 3 M on both dimensions. Rankings were similar to ratings except that fluorescent orange was the highest on perceived hazard, while fluorescent orange and safety red from the ANSI were ranked as the highest in perceived importance. Fluorescent colors convey hazard and importance levels as high as the standard safety red colors. Implications for conveying hazard and importance in warnings through color are discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Identification of endangered or threatened Costa Rican tree species by wood anatomy and fluorescence activity.

    Science.gov (United States)

    Moya, Róger; Wiemann, Michael C; Olivares, Carlos

    2013-09-01

    A total of 45 native Costa Rican tree species are threatened or in danger of extinction, but the Convention on International Trade Endangered Species (CITES) includes only eight of these in its Appendices. However, the identification of other species based on their wood anatomy is limited. The present study objective was to describe and to compare wood anatomy and fluorescence activity in some endangered or threatened species of Costa Rica. A total of 45 (22 endangered and 23 threatened with extinction) wood samples of these species, from the xylaria of the Instituto Tecnológico de Costa Rica and the Forest Products Laboratory in Madison, Wisconsin, were examined. Surface fluorescence was positive in eight species, water extract fluorescence was positive in six species and ethanol extract fluorescence was positive in 24 species. Almost all species were diffuse porous except for occasional (Cedrela odorata, C. fissilis, Cordia gerascanthus) or regular (C. salvadorensis and C. tonduzii) semi-ring porosity. A dendritic vessel arrangement was found in Sideroxylon capari, and pores were solitary in Guaiacum sanctum and Vantanea barbourii. Vessel element length was shortest in Guaiacum sanctum and longest in Humiriastrum guianensis, Minquartia guianensis and Vantanea barbourii. Finally, anatomical information and fluorescence activity were utilized to construct an identification key of species, in which fluorescence is a feature used in identification.

  11. Identification of endangered or threatened Costa Rican tree species by wood anatomy and fluorescence activity

    Directory of Open Access Journals (Sweden)

    Róger Moya

    2013-09-01

    Full Text Available A total of 45 native Costa Rican tree species are threatened or in danger of extinction, but the Convention on International Trade Endangered Species (CITES includes only eight of these in its Appendices. However, the identification of other species based on their wood anatomy is limited. The present study objective was to describe and to compare wood anatomy and fluorescence activity in some endangered or threatened species of Costa Rica. A total of 45 (22 endangered and 23 threatened with extinction wood samples of these species, from the xylaria of the Instituto Tecnológico de Costa Rica and the Forest Products Laboratory in Madison, Wisconsin, were examined. Surface fluorescence was positive in eight species, water extract fluorescence was positive in six species and ethanol extract fluorescence was positive in 24 species. Almost all species were diffuse porous except for occasional (Cedrela odorata, C. fissilis, Cordia gerascanthus or regular (C. salvadorensis and C. tonduzii semi-ring porosity. A dendritic vessel arrangement was found in Sideroxylon capari, and pores were solitary in Guaiacum sanctum and Vantanea barbourii. Vessel element length was shortest in Guaiacum sanctum and longest in Humiriastrum guianensis, Minquartia guianensis and Vantanea barbourii. Finally, anatomical information and fluorescence activity were utilized to construct an identification key of species, in which fluorescence is a feature used in identification.

  12. Total algorithms

    NARCIS (Netherlands)

    Tel, G.

    We define the notion of total algorithms for networks of processes. A total algorithm enforces that a "decision" is taken by a subset of the processes, and that participation of all processes is required to reach this decision. Total algorithms are an important building block in the design of

  13. Multi-institutional Feasibility Study of a Fast Patient Localization Method in Total Marrow Irradiation With Helical Tomotherapy: A Global Health Initiative by the International Consortium of Total Marrow Irradiation

    International Nuclear Information System (INIS)

    Takahashi, Yutaka; Vagge, Stefano; Agostinelli, Stefano; Han, Eunyoung; Matulewicz, Lukasz; Schubert, Kai; Chityala, Ravishankar; Ratanatharathorn, Vaneerat; Tournel, Koen; Penagaricano, Jose A.; Florian, Sterzing; Mahe, Marc-Andre; Verneris, Michael R.; Weisdorf, Daniel J.

    2015-01-01

    Purpose: To develop, characterize, and implement a fast patient localization method for total marrow irradiation. Methods and Materials: Topographic images were acquired using megavoltage computed tomography (MVCT) detector data by delivering static orthogonal beams while the couch traversed through the gantry. Geometric and detector response corrections were performed to generate a megavoltage topogram (MVtopo). We also generated kilovoltage topograms (kVtopo) from the projection data of 3-dimensional CT images to reproduce the same geometry as helical tomotherapy. The MVtopo imaging dose and the optimal image acquisition parameters were investigated. A multi-institutional phantom study was performed to verify the image registration uncertainty. Forty-five MVtopo images were acquired and analyzed with in-house image registration software. Results: The smallest jaw size (front and backup jaws of 0) provided the best image contrast and longitudinal resolution. Couch velocity did not affect the image quality or geometric accuracy. The MVtopo dose was less than the MVCT dose. The image registration uncertainty from the multi-institutional study was within 2.8 mm. In patient localization, the differences in calculated couch shift between the registration with MVtopo-kVtopo and MVCT-kVCT images in lateral, cranial–caudal, and vertical directions were 2.2 ± 1.7 mm, 2.6 ± 1.4 mm, and 2.7 ± 1.1 mm, respectively. The imaging time in MVtopo acquisition at the couch speed of 3 cm/s was <1 minute, compared with ≥15 minutes in MVCT for all patients. Conclusion: Whole-body MVtopo imaging could be an effective alternative to time-consuming MVCT for total marrow irradiation patient localization

  14. Total Quality Management in Academic Libraries: Initial Implementation Efforts. Proceedings from the International Conference on TQM and Academic Libraries (1st, Washington, D.C., April 20-22, 1994).

    Science.gov (United States)

    Rounds, Laura, Ed.; Matthews, Michael, Ed.

    This document contains conference papers, other speeches, and supplementary material from the first International Conference on Total Quality Management (TQM) and Academic Libraries, held in 1994. The conference was comprised of four sessions, and the introductory remarks of each are included, along with transcriptions of each session's…

  15. Magnetic solid-phase extraction for determination of the total malachite green, gentian violet and leucomalachite green, leucogentian violet in aquaculture water by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Zhao, Jiao; Wei, Daqiao; Yang, Yaling

    2016-06-01

    In this study, magnetic multi-walled carbon nanotube nanoparticles were synthesized and used as the adsorbent for the sums of malachite green, gentian violet and leucomalachite green, leucogentian violet in aquaculture water samples followed by high performance liquid chromatography with fluorescence detection. This method was based on in situ reduction of chromic malachite green, gentian violet to colorless leucomalachite green, leucogentian violet with potassium borohydride, respectively. The obtained adsorbent combines the advantages of carbon nanotubes and Fe3 O4 nanoparticles in one material for separation and preconcentration of the reductive dyes in aqueous media. The structure and properties of the prepared nanoparticles were characterized by transmission and scanning electron microscopy, X-ray diffraction, and Fourier-transform infrared spectroscopy. The main parameters affecting the adsorption recoveries were investigated and optimized, including reducing agent concentration, type and amount of sorbent, sample pH, and eluting conditions. Under the optimum conditions, the limits of detection in this method were 0.22 and 0.09 ng/mL for malachite green and gentian violet, respectively. Product recoveries ranged from 87.0 to 92.8% with relative standard deviations from 4.6 to 5.9%. The results indicate that the sorbent is a suitable material for the removal and concentration of triphenylmethane dyes from polluted environmental samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Totally James

    Science.gov (United States)

    Owens, Tom

    2006-01-01

    This article presents an interview with James Howe, author of "The Misfits" and "Totally Joe". In this interview, Howe discusses tolerance, diversity and the parallels between his own life and his literature. Howe's four books in addition to "The Misfits" and "Totally Joe" and his list of recommended books with lesbian, gay, bisexual, transgender,…

  17. Identification of cultured isolates of clinically important yeast species using fluorescent fragment length analysis of the amplified internally transcribed rRNA spacer 2 region

    Directory of Open Access Journals (Sweden)

    Muylaert An

    2002-07-01

    Full Text Available Abstract Background The number of patients with yeast infection has increased during the last years. Also the variety of species of clinical importance has increased. Correct species identification is often important for efficient therapy, but is currently mostly based on phenotypic features and is sometimes time-consuming and depends largely on the expertise of technicians. Therefore, we evaluated the feasibility of PCR-based amplification of the internally transcribed spacer region 2 (ITS2, followed by fragment size analysis on the ABI Prism 310 for the identification of clinically important yeasts. Results A rapid DNA-extraction method, based on simple boiling-freezing was introduced. Of the 26 species tested, 22 could be identified unambiguously by scoring the length of the ITS2-region. No distinction could be made between the species Trichosporon asteroides and T. inkin or between T. mucoides and T. ovoides. The two varieties of Cryptococcus neoformans (var. neoformans and var. gattii could be differentiated from each other due to a one bp length difference of the ITS2 fragment. The three Cryptococcus laurentii isolates were split into two groups according to their ITS2-fragment lengths, in correspondence with the phylogenetic groups described previously. Since the obtained fragment lengths compare well to those described previously and could be exchanged between two laboratories, an internationally usable library of ITS2 fragment lengths can be constructed. Conclusions The existing ITS2 size based library enables identification of most of the clinically important yeast species within 6 hours starting from a single colony and can be easily updated when new species are described. Data can be exchanged between laboratories.

  18. Waveguide evanescent field fluorescence microscopy & its application in cell biology

    Science.gov (United States)

    Hassanzadeh, Abdollah

    There are many powerful microscopy technologies available for the investigation of bulk materials as well as for thin film samples. Nevertheless, for imaging an interface, especially live cells on a substrate and ultra thin-films, only Total Internal Reflection Fluorescence (TIRF) microscopy is available. This TIRF microscopy allows imaging without interference of the bulk. Various approaches are employed in fluorescence microscopy applications to restrict the excitation and detection of fluorophores to a thin region of the specimen. Elimination of background fluorescence from outside the focal plane can dramatically improve the signal-to-noise ratio, and consequently, the spatial resolution of the features or events of interest. TIRF microscopy is an evanescent field based microscopy. In this method, fluorescent dyes are only excited within an evanescent field: roughly within 100 nm above a glass coverslip. This will allow imaging surface and interfacial issues of the glass coverslip and an adjacent material. Waveguide evanescent field fluorescence (WEFF) microscopy is a new development for imaging cell-substrate interactions in real time and in vitro. It is an alternative to TIRF microscopy. In this method the light is coupled into a waveguide via an optical grating. The coupled light propagates as a waveguide mode and exhibits an evanescent field on top of the waveguide. This can be used as a surface-bound illumination source to excite fluorophores. This evanescent field serves as an extremely powerful tool for quality control of thin films, to study cell-substrate contacts, and investigating the effect of external agents and drugs on the cell-substrate interaction in real time and in vitro. This new method has been established and optimized to minimize non-uniformity, scattering and photo bleaching issues. Visualizing and quantifying of the cell-substrates and solid thin films have been carried out by WEFF microscopy. The images of the cell-substrate interface

  19. Red and Green Fluorescence from Oral Biofilms.

    Science.gov (United States)

    Volgenant, Catherine M C; Hoogenkamp, Michel A; Krom, Bastiaan P; Janus, Marleen M; Ten Cate, Jacob M; de Soet, Johannes J; Crielaard, Wim; van der Veen, Monique H

    2016-01-01

    Red and green autofluorescence have been observed from dental plaque after excitation by blue light. It has been suggested that this red fluorescence is related to caries and the cariogenic potential of dental plaque. Recently, it was suggested that red fluorescence may be related to gingivitis. Little is known about green fluorescence from biofilms. Therefore, we assessed the dynamics of red and green fluorescence in real-time during biofilm formation. In addition, the fluorescence patterns of biofilm formed from saliva of eight different donors are described under simulated gingivitis and caries conditions. Biofilm formation was analysed for 12 hours under flow conditions in a microfluidic BioFlux flow system with high performance microscopy using a camera to allow live cell imaging. For fluorescence images dedicated excitation and emission filters were used. Both green and red fluorescence were linearly related with the total biomass of the biofilms. All biofilms displayed to some extent green and red fluorescence, with higher red and green fluorescence intensities from biofilms grown in the presence of serum (gingivitis simulation) as compared to the sucrose grown biofilms (cariogenic simulation). Remarkably, cocci with long chain lengths, presumably streptococci, were observed in the biofilms. Green and red fluorescence were not found homogeneously distributed within the biofilms: highly fluorescent spots (both green and red) were visible throughout the biomass. An increase in red fluorescence from the in vitro biofilms appeared to be related to the clinical inflammatory response of the respective saliva donors, which was previously assessed during an in vivo period of performing no-oral hygiene. The BioFlux model proved to be a reliable model to assess biofilm fluorescence. With this model, a prediction can be made whether a patient will be prone to the development of gingivitis or caries.

  20. Red and Green Fluorescence from Oral Biofilms.

    Directory of Open Access Journals (Sweden)

    Catherine M C Volgenant

    Full Text Available Red and green autofluorescence have been observed from dental plaque after excitation by blue light. It has been suggested that this red fluorescence is related to caries and the cariogenic potential of dental plaque. Recently, it was suggested that red fluorescence may be related to gingivitis. Little is known about green fluorescence from biofilms. Therefore, we assessed the dynamics of red and green fluorescence in real-time during biofilm formation. In addition, the fluorescence patterns of biofilm formed from saliva of eight different donors are described under simulated gingivitis and caries conditions. Biofilm formation was analysed for 12 hours under flow conditions in a microfluidic BioFlux flow system with high performance microscopy using a camera to allow live cell imaging. For fluorescence images dedicated excitation and emission filters were used. Both green and red fluorescence were linearly related with the total biomass of the biofilms. All biofilms displayed to some extent green and red fluorescence, with higher red and green fluorescence intensities from biofilms grown in the presence of serum (gingivitis simulation as compared to the sucrose grown biofilms (cariogenic simulation. Remarkably, cocci with long chain lengths, presumably streptococci, were observed in the biofilms. Green and red fluorescence were not found homogeneously distributed within the biofilms: highly fluorescent spots (both green and red were visible throughout the biomass. An increase in red fluorescence from the in vitro biofilms appeared to be related to the clinical inflammatory response of the respective saliva donors, which was previously assessed during an in vivo period of performing no-oral hygiene. The BioFlux model proved to be a reliable model to assess biofilm fluorescence. With this model, a prediction can be made whether a patient will be prone to the development of gingivitis or caries.

  1. Steady-state acceptor fluorescence anisotropy imaging under evanescent excitation for visualisation of FRET at the plasma membrane.

    Directory of Open Access Journals (Sweden)

    Viviane Devauges

    Full Text Available We present a novel imaging system combining total internal reflection fluorescence (TIRF microscopy with measurement of steady-state acceptor fluorescence anisotropy in order to perform live cell Förster Resonance Energy Transfer (FRET imaging at the plasma membrane. We compare directly the imaging performance of fluorescence anisotropy resolved TIRF with epifluorescence illumination. The use of high numerical aperture objective for TIRF required correction for induced depolarization factors. This arrangement enabled visualisation of conformational changes of a Raichu-Cdc42 FRET biosensor by measurement of intramolecular FRET between eGFP and mRFP1. Higher activity of the probe was found at the cell plasma membrane compared to intracellularly. Imaging fluorescence anisotropy in TIRF allowed clear differentiation of the Raichu-Cdc42 biosensor from negative control mutants. Finally, inhibition of Cdc42 was imaged dynamically in live cells, where we show temporal changes of the activity of the Raichu-Cdc42 biosensor.

  2. Picosecond wide-field time-correlated single photon counting fluorescence microscopy with a delay line anode detector

    Energy Technology Data Exchange (ETDEWEB)

    Hirvonen, Liisa M.; Le Marois, Alix; Suhling, Klaus, E-mail: klaus.suhling@kcl.ac.uk [Department of Physics, King' s College London, Strand, London WC2R 2LS (United Kingdom); Becker, Wolfgang; Smietana, Stefan [Becker & Hickl GmbH, Nahmitzer Damm 30, 12277 Berlin (Germany); Milnes, James; Conneely, Thomas [Photek Ltd., 26 Castleham Rd, Saint Leonards-on-Sea TN38 9NS (United Kingdom); Jagutzki, Ottmar [Institut für Kernphysik, Max-von-Laue-Str. 1, 60438 Frankfurt (Germany)

    2016-08-15

    We perform wide-field time-correlated single photon counting-based fluorescence lifetime imaging (FLIM) with a crossed delay line anode image intensifier, where the pulse propagation time yields the photon position. This microchannel plate-based detector was read out with conventional fast timing electronics and mounted on a fluorescence microscope with total internal reflection (TIR) illumination. The picosecond time resolution of this detection system combines low illumination intensity of microwatts with wide-field data collection. This is ideal for fluorescence lifetime imaging of cell membranes using TIR. We show that fluorescence lifetime images of living HeLa cells stained with membrane dye di-4-ANEPPDHQ exhibit a reduced lifetime near the coverslip in TIR compared to epifluorescence FLIM.

  3. Synchrotron radiation total reflection for rainwater analysis

    International Nuclear Information System (INIS)

    Simabuco, Silvana M.; Matsumoto, Edson

    1999-01-01

    Total reflection X-ray fluorescence analysis excited with synchrotron radiation (SR-TXRF) has been used for rainwater trace element analysis. The samples were collected in four different sites at Campinas City, SP. Standard solutions with gallium as internal standard were prepared for the calibration system. Rainwater samples of 10 μl were putted onto Perspex reflector disk, dried on vacuum and analyzed for 100 s measuring time. The detection limits obtained for K-shell varied from 29 ng.ml -1 for sulfur to 1.3 ng.ml -1 for zinc and copper, while for L-shell the values were 4.5 ng.ml -1 for mercury and 7.0 ng.ml -1 for lead. (author)

  4. Reviews in fluorescence 2010

    CERN Document Server

    Geddes, Chris D

    2011-01-01

    ""Reviews in Fluorescence 2010"", the seventh volume of the book serial from Springer, serves as a comprehensive collection of current trends and emerging hot topics in the field of fluorescence and closely related disciplines. It summarizes the year's progress in fluorescence and its applications, with authoritative analytical reviews specialized enough to be attractive to professional researchers, yet also appealing to the wider audience of scientists in related disciplines of fluorescence. ""Reviews in Fluorescence"" offers an essential reference material for any lab working in the fluoresc

  5. Principles of fluorescence techniques

    CERN Document Server

    2016-01-01

    Fluorescence techniques are being used and applied increasingly in academics and industry. The Principles of Fluorescence Techniques course will outline the basic concepts of fluorescence techniques and the successful utilization of the currently available commercial instrumentation. The course is designed for students who utilize fluorescence techniques and instrumentation and for researchers and industrial scientists who wish to deepen their knowledge of fluorescence applications. Key scientists in the field will deliver theoretical lectures. The lectures will be complemented by the direct utilization of steady-state and lifetime fluorescence instrumentation and confocal microscopy for FLIM and FRET applications provided by leading companies.

  6. PERENCANAAN STRATEGI DALAM UPAYA MENYELARASKAN TUJUAN ORGANISASI DAN TUJUAN KARYAWAN DENGAN PENDEKATAN TOTAL PERFORMANCE SCORECARD (Studi Kasus Departemen Internal Audit Perusahaan Minyak dan Gas Bumi

    Directory of Open Access Journals (Sweden)

    T. Yuri Zagloel puslit

    2008-01-01

    Full Text Available The competition in industry is getting harder, where companies face changes in their environment. So that organization must increase their performance and show their ability to win the competition. This tight competition makes organization has to own innovation where employees grow according to change. In the effort of improving organization performance, it must be an harmony between organization and individual objectives. This research in the oil company Indonesia aims to harmonize it based on Total Performance Scorecard (TPS. This harmonization is done through several phases with the results of a communication among organizational Balance scorecard, scorecard section and Individual Performance plan. These things become a integrated strategic planning of the company. This integrated plan means in the process of planning, it involves departments, sections, and all employees. The advantages are to make sure all employees understand the objective of their departments and their sections, whereas they involve in the process and the implementation of the strategy. Abstract in Bahasa Indonesia: Untuk menghadapi persaingan, umumnya kalangan industri terus berupaya untuk melakukan perbaikan dan peningkatan kinerja. Dalam upaya peningkatan kinerja organisasi, keselarasan antara tujuan organisasi dengan tujuan setiap individu yang ada dalam organisasi merupakan hal yang penting. Penelitian di sebuah perusahaan minyak dan gas bumi ini bertujuan untuk menyelaraskan tujuan organisasi dengan tujuan individu dengan menggunakan pendekatan Total Performance Scorecard. Pendekatan ini mempunyai kekhasan yaitu menyelaraskan tujuan organisasi dengan tujuan individu yang tergambar dalam hubungan antara Organizational Balanced Scorecard, Scorecard Section dan rencana kinerja individu. Hubungan tersebut dapat menjadi rancangan strategi yang terintegrasi bagi perusahaan, yang dalam perumusannya melibatkan pihak departemen, seksi, serta seluruh karyawan yang berada

  7. Comparison of the fluorescent polarization (TDx and the enzymatic competitive (EMIT 2000 immune assays for the measurement of cyclosporin A blood concentration Comparação dos imuno-ensaios de fluorescência polarizada (TDx e enzimático competitivo (EMIT 2000 na dosagem da concentração de ciclosporina A no sangue total

    Directory of Open Access Journals (Sweden)

    Elias David-Neto

    2000-12-01

    Full Text Available Evaluation of Cyclosporin A (CyA blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx and the enzymatic competitive immune assay (EMIT 2000. There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, pA avaliação da concentração sanguínea de ciclosporina A (CyA é necessária em transplantes de órgãos sólidos para obter-se máxima imunosupressão e mínimos efeitos colaterais. Nós comparamos os resultados da concentração de CyA em 50 amostras sanguíneas analisadas pelos métodos dos imuno-ensaios de fluorescência polarizada (TDx e enzimático competitivo (EMIT 2000. Houve uma forte correlação entre ambos métodos para qualquer faixa de concentração de CyA (R=0.99, p<0.001. Os coeficientes de variação intra e interensaio foram menores que 4% para ambos os métodos. O custo para cada análise de CyA foi 50% menor para o EMIT em comparação com o TDx. Concluímos que a metodologia EMIT é tão acurada quanto a de TDx para dosar CyA em amostras sanguíneas. Além disso, a metodologia EMIT é mais prática para ser realizada e mais barata, sendo ainda possível adotá-la para dosagens de CyA em vários horários de um mesmo dia.

  8. Reviews in fluorescence 2008

    CERN Document Server

    Geddes, Chris D

    2010-01-01

    This volume serves as a comprehensive collection of current trends and emerging hot topics in the field of fluorescence spectroscopy. It summarizes the year's progress in fluorescence and its applications as well as includes authoritative analytical reviews.

  9. Fluorescent optical position sensor

    Science.gov (United States)

    Weiss, Jonathan D.

    2005-11-15

    A fluorescent optical position sensor and method of operation. A small excitation source side-pumps a localized region of fluorescence at an unknown position along a fluorescent waveguide. As the fluorescent light travels down the waveguide, the intensity of fluorescent light decreases due to absorption. By measuring with one (or two) photodetectors the attenuated intensity of fluorescent light emitted from one (or both) ends of the waveguide, the position of the excitation source relative to the waveguide can be determined by comparing the measured light intensity to a calibrated response curve or mathematical model. Alternatively, excitation light can be pumped into an end of the waveguide, which generates an exponentially-decaying continuous source of fluorescent light along the length of the waveguide. The position of a photodetector oriented to view the side of the waveguide can be uniquely determined by measuring the intensity of the fluorescent light emitted radially at that location.

  10. A review of the internal components of the second generation of Swedish BWRs in perspective of their importance for the total safety. A diploma work in reactor technology

    International Nuclear Information System (INIS)

    Appelgren, S.; Eriksson, Stefan

    1999-03-01

    An investigation has been done of the second generation of Swedish BWRs, Barsebaeck 1 and 2, and Oskarshamn 2, concerning the vessel internals and theirs significance for the reactor safety. The purpose with this pilot study has been to produce a support for the course of action and to be a source of information for more detailed analyses of the vessel internals. A number of accident scenarios have been depicted and discussed regarding how they might occur and what the consequences might be. It is postulated that they start on account of some vessel internals failing. To be able to develop these scenarios it was necessary to collect and go through a relative large number of analyses and calculations. These have consisted of design conditions, calculation of stress and damage reports. In design conditions are included the maximum loads that a component expect to be subjected to in the course of different postulated averages. The design conditions are the input to the calculation of stress. The damage reports treat and analyse the damages that the internals have been exposed to during the years. For each scenario that has been treated, a judgement has been done about why or why not it is probable to happen. The authors do not claim to have made a probability study along the lines that are commonly accepted. The internal parts that have been the subject for the study are the core head, the feed water spargers, the steam dryers, the core shroud and the core shroud support. Below are the results with argumentations and recommendations. Core head: the core head has the behaviour that contribute most to the complexity of the scenarios. Initiators of this kind of scenarios are postulated weaknesses in the extensions of the bolts fastening the shroud head to the core shroud. A collapse of the extensions of the bolts fastening the shroud head to the core shroud will have a great impact on the reactor safety. Very likely it would lead to absent core cooling and absent

  11. Safe biodegradable fluorescent particles

    Science.gov (United States)

    Martin, Sue I [Berkeley, CA; Fergenson, David P [Alamo, CA; Srivastava, Abneesh [Santa Clara, CA; Bogan, Michael J [Dublin, CA; Riot, Vincent J [Oakland, CA; Frank, Matthias [Oakland, CA

    2010-08-24

    A human-safe fluorescence particle that can be used for fluorescence detection instruments or act as a safe simulant for mimicking the fluorescence properties of microorganisms. The particle comprises a non-biological carrier and natural fluorophores encapsulated in the non-biological carrier. By doping biodegradable-polymer drug delivery microspheres with natural or synthetic fluorophores, the desired fluorescence can be attained or biological organisms can be simulated without the associated risks and logistical difficulties of live microorganisms.

  12. Total internal conversion coefficient of the 260. 9 keV (7/sup +/->3/sup -/) transition in sup(198m)Tl

    Energy Technology Data Exchange (ETDEWEB)

    Venkateswara Rao, N.; Suryanarayana, C.; Narayana, D.G.S.; Bhuloka Reddy, S.; Satynarayana, G.; Sastry, D.L.; Chintalapudi, S.N.

    1986-02-21

    The 1.87 hours 543.7 keV (7/sup +/) isomeric state in /sup 198/Tl is produced via /sup 197/Au(..cap alpha.., 3n)sup(198m)Tl (Esub(..cap alpha..) = 35 MeV) reaction. The total conversion coefficient of 260.9 keV (7/sup +/ -> 3/sup -/) is determined for the first time by the intensity balance method. The value of ..cap alpha..sub(T)(260.9 keV) is found to be 40.1 +- 8.6 which is in good agreement with the theoretical value of Hager and Seltzer for pure M4 transition. The gamma transition probability of the 260.9 keV (M4) is calculated using the present value of ..cap alpha..sub(T) and compared with the single-particle estimate.

  13. Optimization of fluorescent proteins

    NARCIS (Netherlands)

    Bindels, D.S.; Goedhart, J.; Hink, M.A.; van Weeren, L.; Joosen, L.; Gadella (jr.), T.W.J.; Engelborghs, Y.; Visser, A.J.W.G.

    2014-01-01

    Nowadays, fluorescent protein (FP) variants have been engineered to fluoresce in all different colors; to display photoswitchable, or photochromic, behavior; or to show yet other beneficial properties that enable or enhance a still growing set of new fluorescence spectroscopy and microcopy

  14. Fluorescent Biosensors Based on Single-Molecule Counting.

    Science.gov (United States)

    Ma, Fei; Li, Ying; Tang, Bo; Zhang, Chun-Yang

    2016-09-20

    fluorescence signals by specific in vitro/in vivo fluorescent labeling, and consequently, the fluorescent molecules indicate the presence of target molecules. The resultant fluorescence signals may be simply counted by either microfluidic device-integrated confocal microscopy or total internal reflection fluorescence-based single-molecule imaging. We have developed a series of single-molecule counting-based biosensors which can be classified as separation-free and separation-assisted assays. As a proof-of-concept, we demonstrate the applications of single-molecule counting-based biosensors for sensitive detection of various target biomolecules such as DNAs, miRNAs, proteins, enzymes, and intact cells, which may function as the disease-related biomarkers. Moreover, we give a summary of future directions to expand the usability of single-molecule counting-based biosensors including (1) the development of more user-friendly and automated instruments, (2) the discovery of new fluorescent labels and labeling strategies, and (3) the introduction of new concepts for the design of novel biosensors. Due to their high sensitivity, good selectivity, rapidity, and simplicity, we believe that the single-molecule counting-based fluorescent biosensors will indubitably find wide applications in biological research, clinical diagnostics, and drug discovery.

  15. Experimental station for gas phase fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Stankiewicz, M.; Garcia, E. Melero; Ruiz, J. Alvarez; Erman, P.; Hatherly, P.A.; Kivimaeki, A.; Rachlew, E.; Rius i Riu, J.

    2004-01-01

    The details of an experimental setup for gas phase atomic and molecular fluorescence measurements using synchrotron radiation are described in this article. The most significant part of the apparatus is an optical arrangement, which allows for simultaneous measurements of dispersed as well as total fluorescence intensity using an effusive gas jet and an inbuilt gas cell assembled in a convenient plug and measure configuration. The first measurements concerning fluorescence of the N 2 molecule around the N 1s edge obtained with this setup are presented

  16. Total Thyroidectomy

    Directory of Open Access Journals (Sweden)

    Lopez Moris E

    2016-06-01

    Full Text Available Total thyroidectomy is a surgery that removes all the thyroid tissue from the patient. The suspect of cancer in a thyroid nodule is the most frequent indication and it is presume when previous fine needle puncture is positive or a goiter has significant volume increase or symptomes. Less frequent indications are hyperthyroidism when it is refractory to treatment with Iodine 131 or it is contraindicated, and in cases of symptomatic thyroiditis. The thyroid gland has an important anatomic relation whith the inferior laryngeal nerve and the parathyroid glands, for this reason it is imperative to perform extremely meticulous dissection to recognize each one of these elements and ensure their preservation. It is also essential to maintain strict hemostasis, in order to avoid any postoperative bleeding that could lead to a suffocating neck hematoma, feared complication that represents a surgical emergency and endangers the patient’s life.It is essential to run a formal technique, without skipping steps, and maintain prudence and patience that should rule any surgical act.

  17. Fluorescence quantum yield measurements of fluorescent proteins: a laboratory experiment for a biochemistry or molecular biophysics laboratory course.

    Science.gov (United States)

    Wall, Kathryn P; Dillon, Rebecca; Knowles, Michelle K

    2015-01-01

    Fluorescent proteins are commonly used in cell biology to assess where proteins are within a cell as a function of time and provide insight into intracellular protein function. However, the usefulness of a fluorescent protein depends directly on the quantum yield. The quantum yield relates the efficiency at which a fluorescent molecule converts absorbed photons into emitted photons and it is necessary to know for assessing what fluorescent protein is the most appropriate for a particular application. In this work, we have designed an upper-level, biochemistry laboratory experiment where students measure the fluorescence quantum yields of fluorescent proteins relative to a standard organic dye. Four fluorescent protein variants, enhanced cyan fluorescent protein (ECFP), enhanced green fluorescent protein (EGFP), mCitrine, and mCherry, were used, however the methods described are useful for the characterization of any fluorescent protein or could be expanded to fluorescent quantum yield measurements of organic dye molecules. The laboratory is designed as a guided inquiry project and takes two, 4 hr laboratory periods. During the first day students design the experiment by selecting the excitation wavelength, choosing the standard, and determining the concentration needed for the quantum yield experiment that takes place in the second laboratory period. Overall, this laboratory provides students with a guided inquiry learning experience and introduces concepts of fluorescence biophysics into a biochemistry laboratory curriculum. © 2014 The International Union of Biochemistry and Molecular Biology.

  18. Physical and fluorescence data collected using moored buoy casts as part of the IDOE/POLYMODE (International Decade of Ocean Exploration / combination of USSR POLYGON project and US MODE) from 07 December 1975 to 03 January 1977 (NODC Accession 7700569)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Physical and fluorescence data were collected using moored buoy from May 4, 1975 to December 18, 1975. Data were submitted by Massachusetts Institute of Technology;...

  19. Atomic-fluorescence spectrophotometry

    International Nuclear Information System (INIS)

    Bakhturova, N.F.; Yudelevich, I.G.

    1975-01-01

    Atomic-fluorescence spectrophotometry, a comparatively new method for the analysis of trace quantities, has developed rapidly in the past ten years. Theoretical and experimental studies by many workers have shown that atomic-fluorescence spectrophotometry (AFS) is capable of achieving a better limit than atomic absorption for a large number of elements. The present review examines briefly the principles of atomic-fluorescence spectrophotometry and the types of fluorescent transition. The excitation sources, flame and nonflame atomizers, used in AFS are described. The limits of detection achieved up to the present, using flame and nonflame methods of atomization are given

  20. Fluorescence of irradiated hydrocarbons

    International Nuclear Information System (INIS)

    Gulis, I.G.; Evdokimenko, V.M.; Lapkovskij, M.P.; Petrov, P.T.; Gulis, I.M.; Markevich, S.V.

    1977-01-01

    A visible fluorescence has been found out in γ-irradiated aqueous of carbohydrates. Two bands have been distinguished in fluorescence spectra of the irradiated solution of dextran: a short-wave band lambdasub(max)=140 nm (where lambda is a wave length) at lambdasub(β)=380 nm and a long-wave band with lambdasub(max)=540 nm at lambdasub(β)=430 nm. A similar form of the spectrum has been obtained for irradiated solutions of starch, amylopectin, lowmolecular glucose. It has been concluded that a macromolecule of polysaccharides includes fluorescent centres. A relation between fluorescence and α-oxiketon groups formed under irradiation has been pointed out

  1. Application of total reflection X-ray fluorescence spectrometry for ...

    Indian Academy of Sciences (India)

    terest because of the increased awareness about environmental pollution and human health as some ... The presence of heavy elements indicates .... technique applicable to metals and nonmetals equally, both metals and nonmetals present.

  2. Laparoscopic total pancreatectomy

    Science.gov (United States)

    Wang, Xin; Li, Yongbin; Cai, Yunqiang; Liu, Xubao; Peng, Bing

    2017-01-01

    Abstract Rationale: Laparoscopic total pancreatectomy is a complicated surgical procedure and rarely been reported. This study was conducted to investigate the safety and feasibility of laparoscopic total pancreatectomy. Patients and Methods: Three patients underwent laparoscopic total pancreatectomy between May 2014 and August 2015. We reviewed their general demographic data, perioperative details, and short-term outcomes. General morbidity was assessed using Clavien–Dindo classification and delayed gastric emptying (DGE) was evaluated by International Study Group of Pancreatic Surgery (ISGPS) definition. Diagnosis and Outcomes: The indications for laparoscopic total pancreatectomy were intraductal papillary mucinous neoplasm (IPMN) (n = 2) and pancreatic neuroendocrine tumor (PNET) (n = 1). All patients underwent laparoscopic pylorus and spleen-preserving total pancreatectomy, the mean operative time was 490 minutes (range 450–540 minutes), the mean estimated blood loss was 266 mL (range 100–400 minutes); 2 patients suffered from postoperative complication. All the patients recovered uneventfully with conservative treatment and discharged with a mean hospital stay 18 days (range 8–24 days). The short-term (from 108 to 600 days) follow up demonstrated 3 patients had normal and consistent glycated hemoglobin (HbA1c) level with acceptable quality of life. Lessons: Laparoscopic total pancreatectomy is feasible and safe in selected patients and pylorus and spleen preserving technique should be considered. Further prospective randomized studies are needed to obtain a comprehensive understanding the role of laparoscopic technique in total pancreatectomy. PMID:28099344

  3. Membranes and Fluorescence microscopy

    DEFF Research Database (Denmark)

    Bagatolli, Luis

    2009-01-01

    Fluorescence spectroscopy-based techniques using conventional fluorimeters have been extensively applied since the late 1960s to study different aspects of membrane-related phenomena, i.e., mainly relating to lipid-lipid and lipid-protein (peptide) interactions. Even though fluorescence...

  4. Multimodal fluorescence imaging spectroscopy

    NARCIS (Netherlands)

    Stopel, Martijn H W; Blum, Christian; Subramaniam, Vinod; Engelborghs, Yves; Visser, Anthonie J.W.G.

    2014-01-01

    Multimodal fluorescence imaging is a versatile method that has a wide application range from biological studies to materials science. Typical observables in multimodal fluorescence imaging are intensity, lifetime, excitation, and emission spectra which are recorded at chosen locations at the sample.

  5. HER2 Gene Amplification Testing by Fluorescent In Situ Hybridization (FISH): Comparison of the ASCO-College of American Pathologists Guidelines With FISH Scores Used for Enrollment in Breast Cancer International Research Group Clinical Trials.

    Science.gov (United States)

    Press, Michael F; Sauter, Guido; Buyse, Marc; Fourmanoir, Hélène; Quinaux, Emmanuel; Tsao-Wei, Denice D; Eiermann, Wolfgang; Robert, Nicholas; Pienkowski, Tadeusz; Crown, John; Martin, Miguel; Valero, Vicente; Mackey, John R; Bee, Valerie; Ma, Yanling; Villalobos, Ivonne; Campeau, Anaamika; Mirlacher, Martina; Lindsay, Mary-Ann; Slamon, Dennis J

    2016-10-10

    Purpose ASCO and the College of American Pathologists (ASCO-CAP) recently recommended further changes to the evaluation of human epidermal growth factor receptor 2 gene (HER2) amplification by fluorescent in situ hybridization (FISH). We retrospectively assessed the impact of these new guidelines by using annotated Breast Cancer International Research Group (BCIRG) -005, BCIRG-006, and BCIRG-007 clinical trials data for which we have detailed outcomes. Patients and Methods The HER2 FISH status of BCIRG-005/006/007 patients with breast cancers was re-evaluated according to current ASCO-CAP guidelines, which designates five different groups according to HER2 FISH ratio and average HER2 gene copy number per tumor cell: group 1 (in situ hybridization [ISH]-positive): HER2-to-chromosome 17 centromere ratio ≥ 2.0, average HER2 copies ≥ 4.0; group 2 (ISH-positive): ratio ≥ 2.0, copies < 4.0; group 3 (ISH-positive): ratio < 2.0, copies ≥ 6.0; group 4 (ISH-equivocal): ratio < 2.0, copies ≥ 4.0 and < 6.0; and group 5 (ISH-negative): ratio < 2.0, copies < 4.0. We assessed correlations with HER2 protein, clinical outcomes by disease-free survival (DFS) and overall survival (OS) and benefit from trastuzumab therapy (hazard ratio [HR]). Results Among 10,468 patients with breast cancers who were successfully screened for trial entry, 40.8% were in ASCO-CAP ISH group 1, 0.7% in group 2; 0.5% in group 3, 4.1% in group 4, and 53.9% in group 5. Distributions were similar in screened compared with accrued subpopulations. Among accrued patients, FISH group 1 breast cancers were strongly correlated with immunohistochemistry 3+ status (P < .0001), whereas groups 2, 3, 4, and 5 were not; however, groups 2, 4 and, 5 were strongly correlated with immunohistochemistry 0/1+ status (all P < .0001), whereas group 3 was not. Among patients accrued to BCIRG-005, group 4 was not associated with significantly worse DFS or OS compared with group 5. Among patients accrued to BCIRG-006, only

  6. 全髋关节置换与内固定治疗股骨颈骨折临床疗效比较%Comparison of internal fixation with total hip replacement for displaced femoral neck fractures

    Institute of Scientific and Technical Information of China (English)

    屈铁男; 陈洪瑜; 王志刚

    2014-01-01

    control ed trials performed postoperatively have shown that a primary total hip replacement is superior to internal fixation for the treatment of a femoral neck fracture in a relatively healthy, mental y competent, elderly patient. The primary aim of the present study was to evaluate the outcomes. METHODS: 58 patients who had an acute femoral neck fracture were randomly al ocated to be treated with total hip replacement or internal fixation. 24 cases (A group)were treated by IF,and 34 cases(B group) were treated by THR. RESULTS: At the 3.8 years fol ow-up evaluation, the rate of hip complications was 8.8% in the patients treated with total hip replacement and 37.5% in those treated with internal fixation .The hip function was significantly better and the decline in health-related quality of life was less pronounced in the arthroplasty group than it was in the fixation group CONCLUSIONS: Compared with internal fixation, primary total hip replacement provides a better outcome for mental y competent elderly patients with a femoral neck fracture. If we can decrease the rate of the un-union ,then internal fixation was also good method.%对施行内固定或全髋关节置换术后的新鲜老年股骨颈骨折患者的临床随访,总结所取得的经验和教训。材料及方法:我们对1997年6月-2004年10月间施行内固定或全髋关节置换术的老年患者(65岁以上)进行随访,获得随访58例,其中A组24例行空心拉力螺钉固定;B组34例行人工全髋关节置换。对其手术后功能恢复情况平均随访时间3.8年。结果:34例全髋关节置换(T H A)患者术后优良率91.2%(22例);24例内固定(I F)患者术后优良率62.5%;A组严重并发症中有7例为骨折不愈合、股骨头坏死2例。结论:对于老年股骨颈骨折的治疗,全髋关节置换是一种有效的治疗方式;如果能够有效降低较高的骨折不愈合率,多枚中空拉力螺钉内固定也是一种可行的选择。

  7. Proposta do uso de pool de sangue total como controle interno de qualidade em hematologia Proposal for the use of a pool of whole blood as internal quality control in hematology

    Directory of Open Access Journals (Sweden)

    Carina Daniele Schons

    2010-06-01

    Full Text Available INTRODUÇÃO: A confiabilidade dos resultados do laboratório é garantida pela realização do controle de qualidade, que tem como funções básicas análise, pesquisa e prevenção da ocorrência de erros laboratoriais por meio de programas que abrangem tanto o controle interno quanto o externo. OBJETIVO: Propor a padronização de utilização de pool de sangue total como controle interno de qualidade no setor de hematologia. MÉTODO: Foram selecionadas amostras de sangue total, colhidas com ácido etilenodiaminotetracético (EDTA, de mesmos grupo sanguíneo e fator Rh, livres de interferentes, como hemólise, lipemia e icterícia. De um total de 30 ml de sangue total, obtiveram-se três alíquotas de 10 ml cada, às quais foram adicionados, respectivamente, 0 ml (sem adição, 1 ml e 5 ml de glicerol (conservante. As amostras foram avaliadas em contador automático ADVIA® 60. Após determinação dos valores de média e DP, todas as amostras foram avaliadas por um período de 45 dias úteis para confecção do gráfico de Levey-Jennings e verificação da estabilidade da amostra. RESULTADO E CONCLUSÃO: Podemos verificar que o pool de sangue total, preparado de acordo com a metodologia proposta, não apresenta estabilidade necessária para sua utilização, como controle interno alternativo no setor de hematologia.INTRODUCTION: The reliability of laboratory results is ensured by the implementation of quality control, which has basic functions, such as analysis, research and prevention of laboratory errors through programs that encompass both internal and external control. OBJECTIVE: To propose a standard method to use pooled whole blood as internal quality control in the Hematology division. METHOD: The selected whole blood samples were collected with EDTA, belonged to the same blood group and Rh factor and did not present interfering factors, such as hemolysis, lipemia and icterus. From a total of 30 ml of whole blood it was obtained 3

  8. Fluorescent Nanoparticle Uptake for Brain Tumor Visualization

    Directory of Open Access Journals (Sweden)

    Rachel Tréhin

    2006-04-01

    Full Text Available Accurate delineation of tumor margins is vital to the successful surgical resection of brain tumors. We have previously developed a multimodal nanoparticle CLIO-Cy5.5, which is detectable by both magnetic resonance imaging and fluorescence, to assist in intraoperatively visualizing tumor boundaries. Here we examined the accuracy of tumor margin determination of orthotopic tumors implanted in hosts with differing immune responses to the tumor. Using a nonuser-based signal intensity method applied to fluorescent micrographs of 9L gliosarcoma green fluorescent protein (GFP tumors, mean overestimations of 2 and 24 µm were obtained using Cy5.5 fluorescence, compared to the true tumor margin determined by GFP fluorescence, in nude mice and rats, respectively. To resolve which cells internalized the nanoparticle and to quantitate degree of uptake, tumors were disaggregated and cells were analyzed by flow cytometry and fluorescence microscopy. Nanoparticle uptake was seen in both CD11b+ cells (representing activated microglia and macrophages and tumor cells in both animal models by both methods. CD11b+ cells were predominantly found at the tumor margin in both hosts, but were more pronounced at the margin in the rat model. Additional metastatic (CT26 colon and primary (Gli36 glioma brain tumor models likewise demonstrated that the nanoparticle was internalized both by tumor cells and by host cells. Together, these observations suggest that fluorescent nanoparticles provide an accurate method of tumor margin estimation based on a combination of tumor cell and host cell uptake for primary and metastatic tumors in animal model systems and offer potential for clinical translation.

  9. Fluorescence and Spectral Imaging

    Directory of Open Access Journals (Sweden)

    Ralph S. DaCosta

    2007-01-01

    Full Text Available Early identification of dysplasia remains a critical goal for diagnostic endoscopy since early discovery directly improves patient survival because it allows endoscopic or surgical intervention with disease localized without lymph node involvement. Clinical studies have successfully used tissue autofluorescence with conventional white light endoscopy and biopsy for detecting adenomatous colonic polyps, differentiating benign hyperplastic from adenomas with acceptable sensitivity and specificity. In Barrett's esophagus, the detection of dysplasia remains problematic because of background inflammation, whereas in the squamous esophagus, autofluorescence imaging appears to be more dependable. Point fluorescence spectroscopy, although playing a crucial role in the pioneering mechanistic development of fluorescence endoscopic imaging, does not seem to have a current function in endoscopy because of its nontargeted sampling and suboptimal sensitivity and specificity. Other point spectroscopic modalities, such as Raman spectroscopy and elastic light scattering, continue to be evaluated in clinical studies, but still suffer the significant disadvantages of being random and nonimaging. A recent addition to the fluorescence endoscopic imaging arsenal is the use of confocal fluorescence endomicroscopy, which provides real-time optical biopsy for the first time. To improve detection of dysplasia in the gastrointestinal tract, a new and exciting development has been the use of exogenous fluorescence contrast probes that specifically target a variety of disease-related cellular biomarkers using conventional fluorescent dyes and novel potent fluorescent nanocrystals (i.e., quantum dots. This is an area of great promise, but still in its infancy, and preclinical studies are currently under way.

  10. Fluorescent discharge lamp

    Science.gov (United States)

    Mukai, E.; Otsuka, H.; Nomi, K.; Honmo, I.

    1982-01-01

    A rapidly illuminating fluorescent lamp 1,200 mm long and 32.5 mm in diameter with an interior conducting strip which is compatible with conventional fixtures and ballasts is described. The fluorescent lamp is composed of a linear glass tube, electrodes sealed at both ends, mercury and raregas sealed in the glass tube, a fluorescent substance clad on the inner walls of the glass tube, and a clad conducting strip extending the entire length of the glass tube in the axial direction on the inner surface of the tube.

  11. Highly thermostable fluorescent proteins

    Science.gov (United States)

    Bradbury, Andrew M [Santa Fe, NM; Waldo, Geoffrey S [Santa Fe, NM; Kiss, Csaba [Los Alamos, NM

    2011-03-22

    Thermostable fluorescent proteins (TSFPs), methods for generating these and other stability-enhanced proteins, polynucleotides encoding such proteins, and assays and method for using the TSFPs and TSFP-encoding nucleic acid molecules are provided. The TSFPs of the invention show extremely enhanced levels of stability and thermotolerance. In one case, for example, a TSFP of the invention is so stable it can be heated to 99.degree. C. for short periods of time without denaturing, and retains 85% of its fluorescence when heated to 80.degree. C. for several minutes. The invention also provides a method for generating stability-enhanced variants of a protein, including but not limited to fluorescent proteins.

  12. Materials for incandescent and fluorescent lamps

    DEFF Research Database (Denmark)

    Thorsen, Knud Aage

    1996-01-01

    The article gives an overview of the materials systems used for incandescent lamps as well as a brief introduction to the systems used for fluorescent lamps. The materials used for incandescent lamps are doped tungsten used for the filaments, metals and alloys used for terminal and support posts......, lead wires and internal reflectors and screens as well as glasses for the envelope. The physics of bulbs and changes in bulbs during use are elucidated. The cost and energy savings and environmental benefits by replacement of incandescent lamps by fluorescent lamps are presented....

  13. Reviews in fluorescence 2007

    CERN Document Server

    Lakowicz, Joseph R; Geddes, Chris D

    2009-01-01

    This fourth volume in the Springer series summarizes the year's progress in fluorescence, with authoritative analytical reviews specialized enough for professional researchers, yet also appealing to a wider audience of scientists in related fields.

  14. Introduction to fluorescence

    CERN Document Server

    Jameson, David M

    2014-01-01

    "An essential contribution to educating scientists in the principles of fluorescence. It will also be an important addition to the libraries of practitioners applying the principles of molecular fluorescence."-Ken Jacobson, Kenan Distinguished Professor of Cell Biology and Physiology, University of North Carolina at Chapel Hill"An exquisite compendium of fluorescence and its applications in biochemistry enriched by a very exciting historical perspective. This book will become a standard text for graduate students and other scientists."-Drs. Zygmunt (Karol) Gryczynski and Ignacy Gryczynski, University of North Texas Health Science Center"… truly a masterwork, combining clarity, precision, and good humor. The reader, novice or expert, will be pleased with the text and will not stop reading. It is a formidable account of the fluorescence field, which has impacted the life sciences so considerably in the last 60 years."-Jerson L. Silva, M.D., Ph.D., Professor and Director, National Institute of Science and Tech...

  15. Fluorescence (Multiwave) Confocal Microscopy.

    Science.gov (United States)

    Welzel, J; Kästle, Raphaela; Sattler, Elke C

    2016-10-01

    In addition to reflectance confocal microscopy, multiwave confocal microscopes with different laser wavelengths in combination with exogenous fluorophores allow fluorescence mode confocal microscopy in vivo and ex vivo. Fluorescence mode confocal microscopy improves the contrast between the epithelium and the surrounding soft tissue and allows the depiction of certain structures, like epithelial tumors, nerves, and glands. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. A miniaturized oxygen sensor integrated on fiber surface based on evanescent-wave induced fluorescence quenching

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Yan [School of Chemistry and Chemical Engineering, Southwest Petroleum University, Chengdu 610500 (China); Oil and Gas Field Applied Chemistry Key Laboratory of Sichuan Province, Southwest Petroleum University, Chengdu, 610500 (China); Tan, Jun; Wang, Chengjie; Zhu, Ying [School of Chemistry and Chemical Engineering, Southwest Petroleum University, Chengdu 610500 (China); Fang, Shenwen [School of Chemistry and Chemical Engineering, Southwest Petroleum University, Chengdu 610500 (China); Oil and Gas Field Applied Chemistry Key Laboratory of Sichuan Province, Southwest Petroleum University, Chengdu, 610500 (China); Wu, Jiayi; Wang, Qing [School of Chemistry and Chemical Engineering, Southwest Petroleum University, Chengdu 610500 (China); Duan, Ming, E-mail: swpua124@126.com [State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University, Chengdu 610500 (China); School of Chemistry and Chemical Engineering, Southwest Petroleum University, Chengdu 610500 (China); Oil and Gas Field Applied Chemistry Key Laboratory of Sichuan Province, Southwest Petroleum University, Chengdu, 610500 (China)

    2016-11-15

    In this work, a miniaturized sensor was integrated on fiber surface and developed for oxygen determination through evanescent-wave induced fluorescence quenching. The sensor was designed by using light emitting diode (LED) as light source and optical fiber as light transmission element. Tris(2,2′-bipyridyl) ruthenium ([Ru(bpy){sub 3}]{sup 2+}) fluorophore was immobilized in the organically modified silicates (ORMOSILs) film and coated onto the fiber surface. When light propagated by total internal reflection (TIR) in the fiber core, evanescent wave could be produced on the fiber surface and excite [Ru(bpy){sub 3}]{sup 2+} fluorophore to produce fluorescence emission. Then oxygen could be determinated by its quenching effect on the fluorescence and its concentration could be evaluated according to Stern–Volumer model. Through integrating evanescent wave excitation and fluorescence quenching on fiber surface, the sensor was successfully miniaturized and exhibit improved performances of high sensitivity (1.4), excellent repeatability (1.2%) and fast analysis (12 s) for oxygen determination. The sensor provided a newly portable method for in-situ and real-time measurement of oxygen and showed potential for practical oxygen analysis in different application fields. Furthermore, the fabrication of this sensor provides a miniaturized and portable detection platform for species monitoring by simple modular design. - Highlights: • ORMOSILs sensing film immobilized with [Ru(bpy){sub 3}]{sup 2+} fluorophore was coated on fiber surface. • Evanescent wave on the fiber surface was utilized as excitation source to produce fluorescence. • Oxygen was measured based on its quenching effect on evanescent wave-induce fluorescence. • Sensor fabrication was miniaturized by integrating detection and sensing elements on the fiber. • The modular design sensor provides a detection platform for other species monitoring.

  17. TOTAL annual report 2003

    International Nuclear Information System (INIS)

    2004-01-01

    This 2003 annual report of the Group Total provides economical results and information of the society on the following topics: keys data, the corporate governance (Directors charter, board of directors, audit committee, nomination and remuneration committee, internal control procedures, compensation of directors and executive officers), the corporate social responsibility (environmental stewardship, the future of energy management, the safety enhancement, the human resources, ethics and local development), the investor relations, the management report, the upstream exploration and production, the downstream refining, marketing, trading and shipping, the chemicals and financial and legal information. (A.L.B.)

  18. Fluorescence Image Segmentation by using Digitally Reconstructed Fluorescence Images

    OpenAIRE

    Blumer, Clemens; Vivien, Cyprien; Oertner, Thomas G; Vetter, Thomas

    2011-01-01

    In biological experiments fluorescence imaging is used to image living and stimulated neurons. But the analysis of fluorescence images is a difficult task. It is not possible to conclude the shape of an object from fluorescence images alone. Therefore, it is not feasible to get good manual segmented nor ground truth data from fluorescence images. Supervised learning approaches are not possible without training data. To overcome this issues we propose to synthesize fluorescence images and call...

  19. Fluorescence detection of natural RNA using rationally designed "clickable" oligonucleotide probes

    DEFF Research Database (Denmark)

    Okholm, Anders; Kjems, Jørgen; Astakhova, Kira

    2014-01-01

    Herein a reliable approach to the design of effective fluorescent probes for RNA detection is described. The fluorescence signalling of hybridization by internally positioned polyaromatic hydrocarbons and rhodamine dyes was achieved with a low fluorescence background signal, high fluorescence qua...... quantum yields at ambient and elevated temperature, high selectivity and signal specificity of the probes when binding to miR-7 and circRNA targets....

  20. Using Fluorescence Intensity of Enhanced Green Fluorescent Protein to Quantify Pseudomonas aeruginosa

    Directory of Open Access Journals (Sweden)

    Erin Wilson

    2018-05-01

    Full Text Available A variety of direct and indirect methods have been used to quantify planktonic and biofilm bacterial cells. Direct counting methods to determine the total number of cells include plate counts, microscopic cell counts, Coulter cell counting, flow cytometry, and fluorescence microscopy. However, indirect methods are often used to supplement direct cell counting, as they are often more convenient, less time-consuming, and require less material, while providing a number that can be related to the direct cell count. Herein, an indirect method is presented that uses fluorescence emission intensity as a proxy marker for studying bacterial accumulation. A clinical strain of Pseudomonas aeruginosa was genetically modified to express a green fluorescent protein (PA14/EGFP. The fluorescence intensity of EGFP in live cells was used as an indirect measure of live cell density, and was compared with the traditional cell counting methods of optical density (OD600 and plate counting (colony-forming units (CFUs. While both OD600 and CFUs are well-established methods, the use of fluorescence spectroscopy to quantify bacteria is less common. This study demonstrates that EGFP intensity is a convenient reporter for bacterial quantification. In addition, we demonstrate the potential for fluorescence spectroscopy to be used to measure the quantity of PA14/EGFP biofilms, which have important human health implications due to their antimicrobial resistance. Therefore, fluorescence spectroscopy could serve as an alternative or complementary quick assay to quantify bacteria in planktonic cultures and biofilms.

  1. Nine New Fluorescent Probes

    Science.gov (United States)

    Lin, Tsung-I.; Jovanovic, Misa V.; Dowben, Robert M.

    1989-06-01

    Absorption and fluorescence spectroscopic studies are reported here for nine new fluorescent probes recently synthesized in our laboratories: four pyrene derivatives with substituents of (i) 1,3-diacetoxy-6,8-dichlorosulfonyl, (ii) 1,3-dihydroxy-6,8-disodiumsulfonate, (iii) 1,3-disodiumsulfonate, and (iv) l-ethoxy-3,6,8-trisodiumsulfonate groups, and five [7-julolidino] coumarin derivatives with substituents of (v) 3-carboxylate-4-methyl, (vi) 3- methylcarboxylate, (vii) 3-acetate-4-methyl, (viii) 3-propionate-4-methyl, and (ix) 3-sulfonate-4-methyl groups. Pyrene compounds i and ii and coumarin compounds v and vi exhibit interesting absorbance and fluorescence properties: their absorption maxima are red shifted compared to the parent compound to the blue-green region, and the band width broadens considerably. All four blue-absorbing dyes fluoresce intensely in the green region, and the two pyrene compounds emit at such long wavelengths without formation of excimers. The fluorescence properties of these compounds are quite environment-sensitive: considerable spectral shifts and fluorescence intensity changes have been observed in the pH range from 3 to 10 and in a wide variety of polar and hydrophobic solvents with vastly different dielectric constants. The high extinction and fluorescence quantum yield of these probes make them ideal fluorescent labeling reagents for proteins, antibodies, nucleic acids, and cellular organelles. The pH and hydrophobicity-dependent fluorescence changes can be utilized as optical pH and/or hydrophobicity indicators for mapping environmental difference in various cellular components in a single cell. Since all nine probes absorb in the UV, but emit at different wavelengths in the visible, these two groups of compounds offer an advantage of utilizing a single monochromatic light source (e.g., a nitrogen laser) to achieve multi-wavelength detection for flow cytometry application. As a first step to explore potential application in

  2. Nanosecond fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Leskovar, B.

    1985-03-01

    This article is a summary of a short course lecture given in conjunction with the 1984 Nuclear Science Symposium. Measuring systems for nanosecond fluorescence spectroscopy using single-photon counting techniques are presented. These involve systems based on relaxation-type spark gap light pulser and synchronously pumped mode-locked dye lasers. Furthermore, typical characteristics and optimization of operating conditions of the critical components responsible for the system time resolution are discussed. A short comparison of the most important deconvolution methods for numerical analysis of experimental data is given particularly with respect to the signal-to-noise ratio of the fluorescence signal. 22 refs., 8 figs

  3. Fluorescence uranium determination

    International Nuclear Information System (INIS)

    Fernandez Cellini, R.; Crus Castillo, F. de la; Barrera Pinero, R.

    1960-01-01

    An equipment for analysis of uranium by fluorescence was developed in order to determine it at such a low concentration that it can not be determined by the most sensible analytical methods. this new fluorimeter was adapted to measure the fluorescence emitted by the phosphorus sodium fluoride-sodium carbonate-potasium carbonate-uranyl, being excited by ultraviolet light of 3,650 A the intensity of the light emitted was measure with a photomultiplicator RCA 5819 and the adequate electronic equipment. (Author) 19 refs

  4. Study of the air fluorescence by AIRFLY

    Czech Academy of Sciences Publication Activity Database

    Boháčová, Martina

    2009-01-01

    Roč. 190, May (2009), s. 266-271 ISSN 0920-5632. [Cosmic Ray International Seminar 2008. Malfa, 15.09.2008-19.09.2008] R&D Projects: GA MŠk(CZ) LA08016; GA MŠk(CZ) 1M06002 Institutional research plan: CEZ:AV0Z10100502; CEZ:AV0Z10100522 Keywords : air fluorescence * cosmic rays Subject RIV: BF - Elementary Particles and High Energy Physics

  5. S - and N-alkylating agents diminish the fluorescence of fluorescent dye-stained DNA.

    Science.gov (United States)

    Giesche, Robert; John, Harald; Kehe, Kai; Schmidt, Annette; Popp, Tanja; Balzuweit, Frank; Thiermann, Horst; Gudermann, Thomas; Steinritz, Dirk

    2017-01-25

    Sulfur mustard (SM), a chemical warfare agent, causes DNA alkylation, which is believed to be the main cause of its toxicity. SM DNA adducts are commonly used to verify exposure to this vesicant. However, the required analytical state-of-the-art mass-spectrometry methods are complex, use delicate instruments, are not mobile, and require laboratory infrastructure that is most likely not available in conflict zones. Attempts have thus been made to develop rapid detection methods that can be used in the field. The analysis of SM DNA adducts (HETE-G) by immunodetection is a convenient and suitable method. For a diagnostic assessment, HETE-G levels must be determined in relation to the total DNA in the sample. Total DNA can be easily visualized by the use of fluorescent DNA dyes. This study examines whether SM and related compounds affect total DNA staining, an issue that has not been investigated before. After pure DNA was extracted from human keratinocytes (HaCaT cells), DNA was exposed to different S- and N-alkylating agents. Our experiments revealed a significant, dose-dependent decrease in the fluorescence signal of fluorescent dye-stained DNA after exposure to alkylating agents. After mass spectrometry and additional fluorescence measurements ruled out covalent modifications of ethidium bromide (EthBr) by SM, we assumed that DNA crosslinks caused DNA condensation and thereby impaired access of the fluorescent dyes to the DNA. DNA digestion by restriction enzymes restored fluorescence, a fact that strengthened our hypothesis. However, monofunctional agents, which are unable to crosslink DNA, also decreased the fluorescence signal. In subsequent experiments, we demonstrated that protons produced during DNA alkylation caused a pH decrease that was found responsible for the reduction in fluorescence. The use of an appropriate buffer system eliminated the adverse effect of alkylating agents on DNA staining with fluorescent dyes. An appropriate buffer system is thus

  6. Monitoring by fluorescence measurements

    International Nuclear Information System (INIS)

    Malcolme-Lawes, D.J.; Gifford, L.A.

    1981-01-01

    A fluorimetric detector is described in which the fluorescence excitation source may be 3 H, 14 C, 35 S, 147 Pm or 63 Ni. Such a detector can be adapted for use with flowing liquid systems especially liquid chromatography systems. (U.K.)

  7. Fluorescence lifetime based bioassays

    Science.gov (United States)

    Meyer-Almes, Franz-Josef

    2017-12-01

    Fluorescence lifetime (FLT) is a robust intrinsic property and material constant of fluorescent matter. Measuring this important physical indicator has evolved from a laboratory curiosity to a powerful and established technique for a variety of applications in drug discovery, medical diagnostics and basic biological research. This distinct trend was mainly driven by improved and meanwhile affordable laser and detection instrumentation on the one hand, and the development of suitable FLT probes and biological assays on the other. In this process two essential working approaches emerged. The first one is primarily focused on high throughput applications employing biochemical in vitro assays with no requirement for high spatial resolution. The second even more dynamic trend is the significant expansion of assay methods combining highly time and spatially resolved fluorescence data by fluorescence lifetime imaging. The latter approach is currently pursued to enable not only the investigation of immortal tumor cell lines, but also specific tissues or even organs in living animals. This review tries to give an actual overview about the current status of FLT based bioassays and the wide range of application opportunities in biomedical and life science areas. In addition, future trends of FLT technologies will be discussed.

  8. Fluorescent Lamp Replacement Study

    Science.gov (United States)

    2017-07-01

    not be cited for purposes of advertisement. DISPOSITION INSTRUCTIONS: Destroy this document when no longer needed. Do not return to the... recycling , and can be disposed safely in a landfill. (2) LEDs offer reduced maintenance costs and fewer bulb replacements, significantly reducing... recycling . Several fixtures, ballasts and energy efficient fluorescent bulbs that were determined to be in pristine condition were returned to ATC

  9. Statistical filtering in fluorescence microscopy and fluorescence correlation spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Macháň, Radek; Kapusta, Peter; Hof, Martin

    Roč. 406 , č. 20 (2014), s. 4797-4813 ISSN 1618-2642 R&D Projects: GA ČR GBP208/12/G016 Institutional support: RVO:61388955 Keywords : Filtered fluorescence correlation spectroscopy * Fluorescence lifetime correlation spectroscopy * Fluorescence spectral correlation spectroscopy Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.436, year: 2014

  10. Total process surveillance: (TOPS)

    International Nuclear Information System (INIS)

    Millar, J.H.P.

    1992-01-01

    A Total Process Surveillance system is under development which can provide, in real-time, additional process information from a limited number of raw measurement signals. This is achieved by using a robust model based observer to generate estimates of the process' internal states. The observer utilises the analytical reduncancy among a diverse range of transducers and can thus accommodate off-normal conditions which lead to transducer loss or damage. The modular hierarchical structure of the system enables the maximum amount of information to be assimilated from the available instrument signals no matter how diverse. This structure also constitutes a data reduction path thus reducing operator cognitive overload from a large number of varying, and possibly contradictory, raw plant signals. (orig.)

  11. Aplicación de Gestión Total Eficiente de Energía en el Centro Internacional de Salud “La Pradera” ; Application of Total Management Techniques of Energy Efficiency at the International Health Centre "La Pradera”

    Directory of Open Access Journals (Sweden)

    Leyat Fernández Velázquez

    2014-06-01

    Full Text Available En este artículo se presentan los primeros resultados obtenidos de la aplicación de la Metodología de las Técnicas de Gestión Total Eficiente de la Energía en el Centro Internacional de Salud “La Pradera”. Se realizó una caracterización energética del Centro, determinándose la estructura de consumo de los portadores energéticos. Se efectuó una investigación estadística de los datos del Centro durante los años 2010 y 2011, obteniéndose que el portador energético más influyente en el consumo de la instalación es la energía eléctrica. Se analizó la relación entre el índice de consumo kilowatt hora vs habitación-día-ocupada (kWh/HDO para evaluar correctamente la eficiencia energética del centro, determinándose que la temperatura ambiente es un factor significativo en los consumos de electricidad, lo cual conllevó a la obtención de un nuevo índice de consumo que refleja acertadamente el comportamiento del consumo de energía eléctrica en función de los servicios prestados por esta entidad. This article presents the first results of the application of the Methodology for Total Management Techniques of Energy Efficiency at the International Health Centre "La Pradera". It was realized an energetic characterization of the Centre, determining the structure of energy carriers consumption. It was conducted a statistical investigation of the data Centre during the years 2010 and 2011, giving the electricity as the more influential energy consumption of the facility. It was analyzed the relationship between kilowatt hour consumption rate vs day-occupied-room (kWh / HDO to assess correctly the energy efficiency of the Centre concluding that the room temperature is a significant factor in the consumption of electricity, which led to the award of a new index that accurately reflects the consumption behaviour of electric energy consumption based on the services provided by this entity.

  12. Who's who in fluorescence 2008

    CERN Document Server

    Geddes, Chris D

    2008-01-01

    The Journal of Fluorescence's sixth Who's Who directory publishes the names, contact details, specialty keywords, and a brief description of scientists employing fluorescence methodology and instrumentation in their working lives. This is a unique reference.

  13. Versatile single-molecule multi-color excitation and detection fluorescence setup for studying biomolecular dynamics

    KAUST Repository

    Sobhy, M. A.

    2011-11-07

    Single-molecule fluorescence imaging is at the forefront of tools applied to study biomolecular dynamics both in vitro and in vivo. The ability of the single-molecule fluorescence microscope to conduct simultaneous multi-color excitation and detection is a key experimental feature that is under continuous development. In this paper, we describe in detail the design and the construction of a sophisticated and versatile multi-color excitation and emission fluorescence instrument for studying biomolecular dynamics at the single-molecule level. The setup is novel, economical and compact, where two inverted microscopes share a laser combiner module with six individual laser sources that extend from 400 to 640 nm. Nonetheless, each microscope can independently and in a flexible manner select the combinations, sequences, and intensities of the excitation wavelengths. This high flexibility is achieved by the replacement of conventional mechanical shutters with acousto-optic tunable filter (AOTF). The use of AOTF provides major advancement by controlling the intensities, duration, and selection of up to eight different wavelengths with microsecond alternation time in a transparent and easy manner for the end user. To our knowledge this is the first time AOTF is applied to wide-field total internal reflection fluorescence (TIRF) microscopy even though it has been commonly used in multi-wavelength confocal microscopy. The laser outputs from the combiner module are coupled to the microscopes by two sets of four single-mode optic fibers in order to allow for the optimization of the TIRF angle for each wavelength independently. The emission is split into two or four spectral channels to allow for the simultaneous detection of up to four different fluorophores of wide selection and using many possible excitation and photoactivation schemes. We demonstrate the performance of this new setup by conducting two-color alternating excitation single-molecule fluorescence resonance energy

  14. Synthesis and Fluorescence Spectra of Triazolylcoumarin Fluorescent Dyes

    Institute of Scientific and Technical Information of China (English)

    PENG Xian-fu; LI Hong-qi

    2009-01-01

    Much attention is devoted to fluorescent dyes especially those with potential in versatile applications. Reactions under "click" conditions between nonfluorescent 3 - azidocoumarins and terminal alkynes produced 3 -(1, 2, 3- triazol- 1 - yl)cournarins, a novel type of fluorescent dyes with intense fluorescence. The structures of the new coumarins were characterized by 1H NMR, MS, and IR spectra. Fluorescence spectra measurement demonstrated excellent fluorescence performance of the triazolylcoumarins and this click reaction is a promising candidate for bioconjugation and bioimaging applications since both azide and alkynes are quite inert to biological systems.

  15. Fluorescence spectroscopy of dental calculus

    International Nuclear Information System (INIS)

    Bakhmutov, D; Gonchukov, S; Sukhinina, A

    2010-01-01

    The aim of the present study was to investigate the fluorescence properties of dental calculus in comparison with the properties of adjacent unaffected tooth structure using both lasers and LEDs in the UV-visible range for fluorescence excitation. The influence of calculus color on the informative signal is demonstrated. The optimal spectral bands of excitation and registration of the fluorescence are determined

  16. Fluorescence spectroscopy of dental calculus

    Science.gov (United States)

    Bakhmutov, D.; Gonchukov, S.; Sukhinina, A.

    2010-05-01

    The aim of the present study was to investigate the fluorescence properties of dental calculus in comparison with the properties of adjacent unaffected tooth structure using both lasers and LEDs in the UV-visible range for fluorescence excitation. The influence of calculus color on the informative signal is demonstrated. The optimal spectral bands of excitation and registration of the fluorescence are determined.

  17. Fluorescence Imaging Reveals Surface Contamination

    Science.gov (United States)

    Schirato, Richard; Polichar, Raulf

    1992-01-01

    In technique to detect surface contamination, object inspected illuminated by ultraviolet light to make contaminants fluoresce; low-light-level video camera views fluorescence. Image-processing techniques quantify distribution of contaminants. If fluorescence of material expected to contaminate surface is not intense, tagged with low concentration of dye.

  18. Who's who in fluorescence 2005

    CERN Document Server

    Geddes, Chris D

    2006-01-01

    The Journal of Fluorescence's third Who's Who directory publishes the names, contact details, specialty keywords, photographs, and a brief description of scientists employing fluorescence methodology and instrumentation in their working livesThe directory provides company contact details with a brief list of fluorescence-related products.

  19. Fluorescence fluctuation spectroscopy (FFS)

    CERN Document Server

    Tetin, Sergey

    2012-01-01

    This new volume of Methods in Enzymology continues the legacy of this premier serial with quality chapters authored by leaders in the field. This volume covers fluorescence fluctuation spectroscopy and includes chapters on such topics as Förster resonance energy transfer (fret) with fluctuation algorithms, protein corona on nanoparticles by FCS, and FFS approaches to the study of receptors in live cells. Continues the legacy of this premier serial with quality chapters authored by leaders in the field Covers fluorescence fluctuation spectroscopy Contains chapters on such topics as Förster resonance energy transfer (fret) with fluctuation algorithms, protein corona on nanoparticles by FCS, and FFS approaches to the study of receptors in live cells.

  20. Fluorescent quantification of melanin.

    Science.gov (United States)

    Fernandes, Bruno; Matamá, Teresa; Guimarães, Diana; Gomes, Andreia; Cavaco-Paulo, Artur

    2016-11-01

    Melanin quantification is reportedly performed by absorption spectroscopy, commonly at 405 nm. Here, we propose the implementation of fluorescence spectroscopy for melanin assessment. In a typical in vitro assay to assess melanin production in response to an external stimulus, absorption spectroscopy clearly overvalues melanin content. This method is also incapable of distinguishing non-melanotic/amelanotic control cells from those that are actually capable of performing melanogenesis. Therefore, fluorescence spectroscopy is the best method for melanin quantification as it proved to be highly specific and accurate, detecting even small variations in the synthesis of melanin. This method can also be applied to the quantification of melanin in more complex biological matrices like zebrafish embryos and human hair. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Fluorescent nanodiamond for biomedicine

    International Nuclear Information System (INIS)

    Milos Nesladek

    2014-01-01

    NV centers in diamond have gained strong interest as a novel tool for quantum information processing, quantum computing and quantum photonics. These applications are based on fluorescent and spin properties of NV-centres. However, in some conditions NV- can lose an electron and turn to NV0. The occupation of NV0 and NV- charge states depend on the position of their ground states with respect to the Fermi level and the mechanism of the charge transfer. Interestingly, that the charge switch has important implications on applications of fluorescent nanodiamond (fND) to nano-biology and nano-medicine. fND can be used for bio-marking and bio-tracking but also for the monitoring of targeted delivery to the cells. In this presentation we review the current state-of-the art for using fND particles for fluorescent bio imaging in cells and discuss the charge transfer and its luminescence stability by using ultra high sensitive spectroscopy methods to study the NV0 and NV- state occupation. (author)

  2. Mercury mass measurement in fluorescent lamps via neutron activation analysis

    International Nuclear Information System (INIS)

    Viererbl, L.; Vinš, M.; Lahodová, Z.; Fuksa, A.; Kučera, J.; Koleška, M.; Voljanskij, A.

    2015-01-01

    Mercury is an essential component of fluorescent lamps. Not all fluorescent lamps are recycled, resulting in contamination of the environment with toxic mercury, making measurement of the mercury mass used in fluorescent lamps important. Mercury mass measurement of lamps via instrumental neutron activation analysis (NAA) was tested under various conditions in the LVR-15 research reactor. Fluorescent lamps were irradiated in different positions in vertical irradiation channels and a horizontal channel in neutron fields with total fluence rates from 3×10 8 cm −2 s −1 to 10 14 cm −2 s −1 . The 202 Hg(n,γ) 203 Hg nuclear reaction was used for mercury mass evaluation. Activities of 203 Hg and others induced radionuclides were measured via gamma spectrometry with an HPGe detector at various times after irradiation. Standards containing an Hg 2 Cl 2 compound were used to determine mercury mass. Problems arise from the presence of elements with a large effective cross section in luminescent material (europium, antimony and gadolinium) and glass (boron). The paper describes optimization of the NAA procedure in the LVR-15 research reactor with particular attention to influence of neutron self-absorption in fluorescent lamps. - Highlights: • Mercury is an essential component of fluorescent lamps. • Fluorescent lamps were irradiated in neutron fields in research reactor. • 203 Hg induced radionuclide activity was measured using gamma spectrometry. • Mercury mass in fluorescent lamps can be measured by neutron activation analysis.

  3. Subunits of highly Fluorescent Protein R-Phycoerythrin as Probes for Cell Imaging and Single-Molecule Detection

    Energy Technology Data Exchange (ETDEWEB)

    Isailovic, Dragan [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    The purposes of our research were: (1) To characterize subunits of highly fluorescent protein R-Phycoerythrin (R-PE) and check their suitability for single-molecule detection (SMD) and cell imaging, (2) To extend the use of R-PE subunits through design of similar proteins that will be used as probes for microscopy and spectral imaging in a single cell, and (3) To demonstrate a high-throughput spectral imaging method that will rival spectral flow cytometry in the analysis of individual cells. We first demonstrated that R-PE subunits have spectroscopic and structural characteristics that make them suitable for SMD. Subunits were isolated from R-PE by high-performance liquid chromatography (HPLC) and detected as single molecules by total internal reflection fluorescence microscopy (TIRFM). In addition, R-PE subunits and their enzymatic digests were characterized by several separation and detection methods including HPLC, capillary electrophoresis, sodium dodecyl sulfate-polyacrilamide gel electrophoresis (SDS-PAGE) and HPLC-electrospray ionization mass spectrometry (ESI-MS). Favorable absorption and fluorescence of the R-PE subunits and digest peptides originate from phycoerythrobilin (PEB) and phycourobilin (PUB) chromophores that are covalently attached to cysteine residues. High absorption coefficients and strong fluorescence (even under denaturing conditions), broad excitation and emission fluorescence spectra in the visible region of electromagnetic spectrum, and relatively low molecular weights make these molecules suitable for use as fluorescence labels of biomolecules and cells. We further designed fluorescent proteins both in vitro and in vivo (in Escherichia coli) based on the highly specific attachment of PEB chromophore to genetically expressed apo-subunits of R-PE. In one example, apo-alpha and apo-beta R-PE subunits were cloned from red algae Polisiphonia boldii (P. boldii), and expressed in E. coli. Although expressed apo-subunits formed inclusion

  4. Compact 3D printed module for fluorescence and label-free imaging using evanescent excitation

    Science.gov (United States)

    Pandey, Vikas; Gupta, Shalini; Elangovan, Ravikrishnan

    2018-01-01

    Total internal reflection fluorescence (TIRF) microscopy is widely used for selective excitation and high-resolution imaging of fluorophores, and more recently label-free nanosized objects, with high vertical confinement near a liquid-solid interface. Traditionally, high numerical aperture objectives (>1.4) are used to simultaneously generate evanescent waves and collect fluorescence emission signals which limits their use to small area imaging (filters to prevent specular reflection within the objective lenses. We have developed a compact 3D module called cTIRF that can generate evanescent waves in microscope glass slides via a planar waveguide illumination. The module can be attached as a fixture to any existing optical microscope, converting it into a TIRF and enabling high signal-to-noise ratio (SNR) fluorescence imaging using any magnification objective. As the incidence optics is perpendicular to the detector, label-free evanescent scattering-based imaging of submicron objects can also be performed without using emission filters. SNR is significantly enhanced in this case as compared to cTIRF alone, as seen through our model experiments performed on latex beads and mammalian cells. Extreme flexibility and the low cost of our approach makes it scalable for limited resource settings.

  5. Adaptive Spot Detection With Optimal Scale Selection in Fluorescence Microscopy Images.

    Science.gov (United States)

    Basset, Antoine; Boulanger, Jérôme; Salamero, Jean; Bouthemy, Patrick; Kervrann, Charles

    2015-11-01

    Accurately detecting subcellular particles in fluorescence microscopy is of primary interest for further quantitative analysis such as counting, tracking, or classification. Our primary goal is to segment vesicles likely to share nearly the same size in fluorescence microscopy images. Our method termed adaptive thresholding of Laplacian of Gaussian (LoG) images with autoselected scale (ATLAS) automatically selects the optimal scale corresponding to the most frequent spot size in the image. Four criteria are proposed and compared to determine the optimal scale in a scale-space framework. Then, the segmentation stage amounts to thresholding the LoG of the intensity image. In contrast to other methods, the threshold is locally adapted given a probability of false alarm (PFA) specified by the user for the whole set of images to be processed. The local threshold is automatically derived from the PFA value and local image statistics estimated in a window whose size is not a critical parameter. We also propose a new data set for benchmarking, consisting of six collections of one hundred images each, which exploits backgrounds extracted from real microscopy images. We have carried out an extensive comparative evaluation on several data sets with ground-truth, which demonstrates that ATLAS outperforms existing methods. ATLAS does not need any fine parameter tuning and requires very low computation time. Convincing results are also reported on real total internal reflection fluorescence microscopy images.

  6. Correlated Fluorescence-Atomic Force Microscopy Studies of the Clathrin Mediated Endocytosis in SKMEL Cells

    Science.gov (United States)

    Smith, Steve; Hor, Amy; Luu, Anh; Kang, Lin; Scott, Brandon; Bailey, Elizabeth; Hoppe, Adam

    Clathrin-mediated endocytosis is one of the central pathways for cargo transport into cells, and plays a major role in the maintenance of cellular functions, such as intercellular signaling, nutrient intake, and turnover of plasma membrane in cells. The clathrin-mediated endocytosis process involves invagination and formation of clathrin-coated vesicles. However, the biophysical mechanisms of vesicle formation are still debated. We investigate clathrin vesicle formation mechanisms through the utilization of tapping-mode atomic force microscopy for high resolution topographical imaging in neutral buffer solution of unroofed cells exposing the inner membrane, combined with fluorescence imaging to definitively label intracellular constituents with specific fluorescent fusion proteins (actin filaments labeled with green phalloidin-antibody and clathrin coated vesicles with the fusion protein Tq2) in SKMEL (Human Melanoma) cells. Results from our work are compared against dynamical polarized total internal fluorescence (TIRF), super-resolution photo-activated localization microscopy (PALM) and transmission electron microscopy (TEM) to draw conclusions regarding the prominent model of vesicle formation in clathrin-mediated endocytosis. Funding provided by NSF MPS/DMR/BMAT award # 1206908.

  7. Fluorescence confocal endomicroscopy in biological imaging

    Science.gov (United States)

    Delaney, Peter; Thomas, Steven; Allen, John; McLaren, Wendy; Murr, Elise; Harris, Martin

    2007-02-01

    In vivo fluorescence microscopic imaging of biological systems in human disease states and animal models is possible with high optical resolution and mega pixel point-scanning performance using optimised off-the-shelf turn-key devices. There are however various trade-offs between tissue access and instrument performance when miniaturising in vivo microscopy systems. A miniature confocal scanning technology that was developed for clinical human endoscopy has been configured into a portable device for direct hand-held interrogation of living tissue in whole animal models (Optiscan FIVE-1 system). Scanning probes of 6.3mm diameter with a distal tip diameter of 5.0mm were constructed either in a 150mm length for accessible tissue, or a 300mm probe for laparoscopic interrogation of internal tissues in larger animal models. Both devices collect fluorescence confocal images (excitation 488 nm; emission >505 or >550 nm) comprised of 1024 x 1204 sampling points/image frame, with lateral resolution 0.7um; axial resolution 7um; FOV 475 x 475um. The operator can dynamically control imaging depth from the tissue surface to approx 250um in 4um steps via an internally integrated zaxis actuator. Further miniaturisation is achieved using an imaging contact probe based on scanning the proximal end of a high-density optical fibre bundle (~30,000 fibres) of small animal organs, albeit at lower resolution (30,000 sampling points/image). In rodent models, imaging was performed using various fluorescent staining protocols including fluorescently labelled receptor ligands, labelled antibodies, FITC-dextrans, vital dyes and labelled cells administered topically or intravenously. Abdominal organs of large animals were accessed laparoscopically and contrasted using i.v. fluorescein-sodium. Articular cartilage of sheep and pigs was fluorescently stained with calcein-AM or fluorescein. Surface and sub-surface cellular and sub-cellular details could be readily visualised in vivo at high

  8. Depth profile analysis of non-specific fluorescence and color of tooth tissues after peroxide bleaching.

    Science.gov (United States)

    Klukowska, Malgorzata; Götz, Hermann; White, Donald J; Zoladz, James; Schwarz, Björn-Olaf; Duschner, Heinz

    2013-02-01

    To examine laboratory changes of endogenous non-specific fluorescence and color throughout subsurface of tooth structures prior to and following peroxide bleaching. Extracted human teeth were cross sectioned and mounted on glass slides. Cross sections were examined for internal color (digital camera) and nonspecific fluorescence (microRaman spectroscopy) throughout the tooth structure at specified locations. Surfaces of sections were then saturation bleached for 70 hours with a gel containing 6% hydrogen peroxide. Cross sections were reexamined for color and non-specific fluorescence changes. Unbleached enamel, dentin-enamel junction and dentin exhibit different CIELab color and non-specific fluorescence properties. Bleaching of teeth produced significant changes in color of internal cross sections and substantial reductions of non-specific fluorescence levels within enamel dentin and DEJ. Enamel and dentin non-specific fluorescence were reduced to common values with bleaching with enamel and the DEJ showing larger reductions than dentin.

  9. Fluorescent microthermographic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Barton, D.L.

    1993-09-01

    In the early days of microelectronics, design rules and feature sizes were large enough that sub-micron spatial resolution was not needed. Infrared or IR thermal techniques were available that calculated the object`s temperature from infrared emission. There is a fundamental spatial resolution limitation dependent on the wavelengths of light being used in the image formation process. As the integrated circuit feature sizes began to shrink toward the one micron level, the limitations imposed on IR thermal systems became more pronounced. Something else was needed to overcome this limitation. Liquid crystals have been used with great success, but they lack the temperature measurement capabilities of other techniques. The fluorescent microthermographic imaging technique (FMI) was developed to meet this need. This technique offers better than 0.01{degrees}C temperature resolution and is diffraction limited to 0.3 {mu}m spatial resolution. While the temperature resolution is comparable to that available on IR systems, the spatial resolution is much better. The FMI technique provides better spatial resolution by using a temperature dependent fluorescent film that emits light at 612 nm instead of the 1.5 {mu}m to 12 {mu}m range used by IR techniques. This tutorial starts with a review of blackbody radiation physics, the process by which all heated objects emit radiation to their surroundings, in order to understand the sources of information that are available to characterize an object`s surface temperature. The processes used in infrared thermal imaging are then detailed to point out the limitations of the technique but also to contrast it with the FMI process. The FMI technique is then described in detail, starting with the fluorescent film physics and ending with a series of examples of past applications of FMI.

  10. Development and Comparison of a Rapid Isothermal Nucleic Acid Amplification Test for Typing of Herpes Simplex Virus Types 1 and 2 on a Portable Fluorescence Detector

    Science.gov (United States)

    Tong, Yanhong; McCarthy, Kaitlin; Kong, Huimin; Lemieux, Bertrand

    2013-01-01

    We have developed a rapid and simple molecular test, the IsoGlow HSV Typing assay, for the detection and typing of herpes simplex virus (type 1 and 2) from genital or oral lesions. Clinical samples suspended in viral transport mediums are simply diluted and then added to a helicase-dependent amplification master mix. The amplification and detection were performed on a portable fluorescence detector called the FireFly instrument. Detection of amplification products is based on end-point analysis using cycling probe technology. An internal control nucleic acid was included in the amplification master mix to monitor the presence of amplification inhibitors in the samples. Because the device has only two fluorescence detection channels, two strategies were developed and compared to detect the internal control template: internal control detected by melting curve analysis using a dual-labeled probe, versus internal control detection using end-point fluorescence release by a CPT probe at a lower temperature. Both have a total turnaround time of about 1 hour. Clinical performance relative to herpes viral culture was evaluated using 176 clinical specimens. Both formats of the IsoGlow HSV typing assay had sensitivities comparable to that of the Food and Drug Administration–cleared IsoAmp HSV (BioHelix Corp., Beverly MA) test and specificity for the two types of HSV comparable to that of ELVIS HSV (Diagnostic Hybrids, Athens, OH). PMID:22951487

  11. Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.

    Science.gov (United States)

    DeRose, Paul C; Resch-Genger, Ute

    2010-03-01

    Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.

  12. Enhanced efficiency of a fluorescing nanoparticle with a silver shell

    Energy Technology Data Exchange (ETDEWEB)

    Choy, Wallace C H; Chen Xuewen [Department of Electrical and Electronic Engineering, University of Hong Kong, Pokfulam Road (Hong Kong); He Sailing [Centre for Optical and Electromagnetic Research, Zhejiang University, Zhijingang campus, Hangzhou 310058 (China)], E-mail: chchoy@eee.hku.hk

    2009-09-01

    Spontaneous emission (SE) rate and the fluorescence efficiency of a bare fluorescing nanoparticle (NP) and the NP with a silver nanoshell are analyzed rigorously by using a classical electromagnetic approach with the consideration of the nonlocal effect of the silver nano-shell. The dependences of the SE rate and the fluorescence efficiency on the core-shell structure are carefully studied and the physical interpretations of the results are addressed. The results show that the SE rate of a bare NP is much slower than that in the infinite medium by almost an order of magnitude and consequently the fluorescence efficiency is usually low. However, by encapsulating the NP with a silver shell, highly efficient fluorescence can be achieved as a result of a large Purcell enhancement and high out-coupling efficiency (OQE) for a well-designed core-shell structure. We also show that a higher SE rate may not offer a larger fluorescence efficiency since the fluorescence efficiency not only depends on the internal quantum yield but also the OQE.

  13. Role of charge transfer and spin-orbit coupling in fluorescence quenching : a case study with oxonine and substituted benzenes

    OpenAIRE

    Föll, Rudolf E.; Kramer, Horst E. A.; Steiner, Ulrich

    1990-01-01

    Fluorescence quenching of oxonine in methanol was investigated by means of a computerized dye laser flash spectrometer for the ∆G°et, dependence of the quenching rate constant (kq) and the efficiencies of induced dye triplet formation (ηT), reduced dye radical formation (ηR), and induced internal conversion. A total of 34 substituted benzenes including 20 monohalogenated benzenes, toluenes, and anisoles were used as quenchers spanning a range of -0.85 ≤ ∆G°et ≤ 1.4 eV for a possible photoelec...

  14. A fluorescence scanning electron microscope

    International Nuclear Information System (INIS)

    Kanemaru, Takaaki; Hirata, Kazuho; Takasu, Shin-ichi; Isobe, Shin-ichiro; Mizuki, Keiji; Mataka, Shuntaro; Nakamura, Kei-ichiro

    2009-01-01

    Fluorescence techniques are widely used in biological research to examine molecular localization, while electron microscopy can provide unique ultrastructural information. To date, correlative images from both fluorescence and electron microscopy have been obtained separately using two different instruments, i.e. a fluorescence microscope (FM) and an electron microscope (EM). In the current study, a scanning electron microscope (SEM) (JEOL JXA8600 M) was combined with a fluorescence digital camera microscope unit and this hybrid instrument was named a fluorescence SEM (FL-SEM). In the labeling of FL-SEM samples, both Fluolid, which is an organic EL dye, and Alexa Fluor, were employed. We successfully demonstrated that the FL-SEM is a simple and practical tool for correlative fluorescence and electron microscopy.

  15. Numerical simulation study for atomic-resolution x-ray fluorescence holography

    International Nuclear Information System (INIS)

    Xie Honglan; Gao Hongyi; Chen Jianwen; Xiong Shisheng; Xu Zhizhan; Wang Junyue; Zhu Peiping; Xian Dingchang

    2003-01-01

    Based on the principle of x-ray fluorescence holography, an iron single crystal model of a body-centred cubic lattice is numerically simulated. From the fluorescence hologram produced numerically, the Fe atomic images were reconstructed. The atomic images of the (001), (100), (010) crystallographic planes were consistent with the corresponding atomic positions of the model. The result indicates that one can obtain internal structure images of single crystals at atomic-resolution by using x-ray fluorescence holography

  16. Continuous distal migration and internal rotation of the C-stem prosthesis without any adverse clinical effects: an RSA study of 33 primary total hip arthroplasties followed for up to ten years.

    Science.gov (United States)

    von Schewelov, T; Carlsson, A; Sanzén, L; Besjakov, J

    2014-05-01

    In 2005, we demonstrated that the polished triple-tapered C-stem at two years had migrated distally and rotated internally. From that series, 33 patients have now been followed radiologically, clinically and by radiostereometric analysis (RSA) for up to ten years. The distal migration within the cement mantle had continued and reached a mean of 2 mm (0.5 to 4.0) at ten years. Internal rotation, also within the cement mantle, was a mean 3.8° (external 1.6° to internal 6.6°) The cement mantle did not show any sign of migration or loosening in relation to the femoral bone. There were no clinical or radiological signs indicating that the migration or rotation within the cement mantle had had any adverse effects for the patients.

  17. Development of a fluorescent cryocooler

    International Nuclear Information System (INIS)

    Edwards, B.C.; Buchwald, M.I.; Epstein, R.I.; Gosnell, T.R.; Mungan, C.E.

    1995-01-01

    Recent work at Los Alamos National Laboratory has demonstrated the physical principles for a new type of solid-state cryocooler based on anti-Stokes fluorescence. Design studies indicate that a vibration-free, low-mass ''fluorescent cryocooler'' could operate for years with efficiencies and cooling powers comparable to current commercial systems. This paper presents concepts for a fluorescent cryocooler, design considerations and expected performance

  18. Fluorescence of ceramic color standards

    International Nuclear Information System (INIS)

    Koo, Annette; Clare, John F.; Nield, Kathryn M.; Deadman, Andrew; Usadi, Eric

    2010-01-01

    Fluorescence has been found in color standards available for use in calibration and verification of color measuring instruments. The fluorescence is excited at wavelengths below about 600 nm and emitted above 700 nm, within the response range of silicon photodiodes, but at the edge of the response of most photomultipliers and outside the range commonly scanned in commercial colorimeters. The degree of fluorescence on two of a set of 12 glossy ceramic tiles is enough to introduce significant error when those tiles have been calibrated in one mode of measurement and are used in another. We report the nature of the fluorescence and the implications for color measurement.

  19. Recent development of fluorescent imaging for specific detection of tumors

    International Nuclear Information System (INIS)

    Nakata, Eiji; Morii, Takashi; Uto, Yoshihiro; Hori, Hitoshi

    2011-01-01

    Increasing recent studies on fluorescent imaging for specific detection of tumors are described here on strategies of molecular targeting, metabolic specificity and hypoxic circumstance. There is described an instance of a conjugate of antibody and pH-activable fluorescent ligand, which specifically binds to the tumor cells, is internalized in the cellular lysozomes where their pH is low, and then is activated to become fluorescent only in viable tumor cells. For the case of metabolic specificity, excessive loading of the precursor (5-aminolevulinic acid) of protoporphyrin IX (ppIX), due to their low activity to convert ppIX to heme B, results in making tumors observable in red as ppIX emits fluorescence (red, 585 nm) when excited by blue ray of 410 nm. Similarly, imaging with indocyanine green which is accumulated in hepatoma cells is reported in success in detection of small lesion and metastasis when the dye is administered during operation. Reductive reactions exceed in tumor hypoxic conditions, of which feature is usable for imaging. Conjugates of nitroimidazole and fluorescent dye are reported to successfully image tumors by nitro reduction. Authors' UTX-12 is a non-fluorescent nitroaromatic derivative of pH-sensitive fluorescent dye seminaphtharhodafluor (SNARF), and is designed for the nitro group, the hypoxia-responding sensor, to be reduced in tumor hypoxic conditions and then for the aromatic moiety to be cleaved to release free SNARF. Use of hypoxia-inducible factor-1 (HIF-1) for imaging has been also reported in many. As above, studies on fluorescent imaging for specific detection of tumors are mostly at fundamental step but its future is conceivably promising along with advances in other technology like fluorescent endoscopy and multimodal imaging. (author)

  20. In-stem labelling allows visualization of DNA strand displacements by distinct fluorescent colour change.

    Science.gov (United States)

    Barrois, Sebastian; Wagenknecht, Hans-Achim

    2013-05-21

    The combination of thiazole orange (TO) and thiazole red (TR) as an internal pair of fluorescent DNA base surrogates ("DNA traffic lights") allows us to follow at least two consecutive DNA strand displacements in real time through a distinct fluorescence colour change from green to red and vice versa.

  1. Proteomic Analysis of Bovine Pregnancy-specific Serum Proteins by 2D Fluorescence Difference Gel Electrophoresis

    Science.gov (United States)

    Lee, Jae Eun; Lee, Jae Young; Kim, Hong Rye; Shin, Hyun Young; Lin, Tao; Jin, Dong Il

    2015-01-01

    Two dimensional-fluorescence difference gel electrophoresis (2D DIGE) is an emerging technique for comparative proteomics, which improves the reproducibility and reliability of differential protein expression analysis between samples. The purpose of this study was to investigate bovine pregnancy-specific proteins in the proteome between bovine pregnant and non-pregnant serum using DIGE technique. Serums of 2 pregnant Holstein dairy cattle at day 21 after artificial insemination and those of 2 non-pregnant were used in this study. The pre-electrophoretic labeling of pregnant and non-pregnant serum proteins were mixed with Cy3 and Cy5 fluorescent dyes, respectively, and an internal standard was labeled with Cy2. Labeled proteins with Cy2, Cy3, and Cy5 were separated together in a single gel, and then were detected by fluorescence image analyzer. The 2D DIGE method using fluorescence CyDye DIGE flour had higher sensitivity than conventional 2D gel electrophoresis, and showed reproducible results. Approximately 1,500 protein spots were detected by 2D DIGE. Several proteins showed a more than 1.5-fold up and down regulation between non-pregnant and pregnant serum proteins. The differentially expressed proteins were identified by MALDI-TOF mass spectrometer. A total 16 protein spots were detected to regulate differentially in the pregnant serum, among which 7 spots were up-regulated proteins such as conglutinin precursor, modified bovine fibrinogen and IgG1, and 6 spots were down-regulated proteins such as hemoglobin, complement component 3, bovine fibrinogen and IgG2a three spots were not identified. The identified proteins demonstrate that early pregnant bovine serum may have several pregnancy-specific proteins, and these could be a valuable information for the development of pregnancy-diagnostic markers in early pregnancy bovine serum. PMID:25925056

  2. Proteomic Analysis of Bovine Pregnancy-specific Serum Proteins by 2D Fluorescence Difference Gel Electrophoresis

    Directory of Open Access Journals (Sweden)

    Jae Eun Lee

    2015-06-01

    Full Text Available Two dimensional-fluorescence difference gel electrophoresis (2D DIGE is an emerging technique for comparative proteomics, which improves the reproducibility and reliability of differential protein expression analysis between samples. The purpose of this study was to investigate bovine pregnancy-specific proteins in the proteome between bovine pregnant and non-pregnant serum using DIGE technique. Serums of 2 pregnant Holstein dairy cattle at day 21 after artificial insemination and those of 2 non-pregnant were used in this study. The pre-electrophoretic labeling of pregnant and non-pregnant serum proteins were mixed with Cy3 and Cy5 fluorescent dyes, respectively, and an internal standard was labeled with Cy2. Labeled proteins with Cy2, Cy3, and Cy5 were separated together in a single gel, and then were detected by fluorescence image analyzer. The 2D DIGE method using fluorescence CyDye DIGE flour had higher sensitivity than conventional 2D gel electrophoresis, and showed reproducible results. Approximately 1,500 protein spots were detected by 2D DIGE. Several proteins showed a more than 1.5-fold up and down regulation between non-pregnant and pregnant serum proteins. The differentially expressed proteins were identified by MALDI-TOF mass spectrometer. A total 16 protein spots were detected to regulate differentially in the pregnant serum, among which 7 spots were up-regulated proteins such as conglutinin precursor, modified bovine fibrinogen and IgG1, and 6 spots were down-regulated proteins such as hemoglobin, complement component 3, bovine fibrinogen and IgG2a three spots were not identified. The identified proteins demonstrate that early pregnant bovine serum may have several pregnancy-specific proteins, and these could be a valuable information for the development of pregnancy-diagnostic markers in early pregnancy bovine serum.

  3. Characterization by fluorescence of dissolved organic matter in rural drinking water storage tanks in Morocco.

    Science.gov (United States)

    Aziz, Faissal; Ouazzani, Naaila; Mandi, Laila; Assaad, Aziz; Pontvianne, Steve; Poirot, Hélène; Pons, Marie-Noëlle

    2018-04-01

    Water storage tanks, fed directly from the river through opened channels, are particular systems used for water supply in rural areas in Morocco. The stored water is used as drinking water by the surrounding population without any treatment. UV-visible spectroscopy and fluorescence spectroscopy (excitation-emission matrices and synchronous fluorescence) have been tested as rapid methods to assess the quality of the water stored in the reservoirs as well as along the river feeding them. Synchronous fluorescence spectra (SFS50), collected with a difference of 50 nm between excitation and emission wavelengths, revealed a high tryptophan-like fluorescence, indicative of a pollution induced by untreated domestic and/or farm wastewater. The best correlations were obtained between the total SFS50 fluorescence and dissolved organic carbon (DOC) and biological oxygen demand, showing that the contribution of humic-like fluorescent substances cannot be neglected to rapidly assess reservoir water quality in terms of DOC by fluorescence spectroscopy.

  4. Fluorescent genetic barcoding in mammalian cells for enhanced multiplexing capabilities in flow cytometry.

    Science.gov (United States)

    Smurthwaite, Cameron A; Hilton, Brett J; O'Hanlon, Ryan; Stolp, Zachary D; Hancock, Bryan M; Abbadessa, Darin; Stotland, Aleksandr; Sklar, Larry A; Wolkowicz, Roland

    2014-01-01

    The discovery of the green fluorescent protein from Aequorea victoria has revolutionized the field of cell and molecular biology. Since its discovery a growing panel of fluorescent proteins, fluorophores and fluorescent-coupled staining methodologies, have expanded the analytical capabilities of flow cytometry. Here, we exploit the power of genetic engineering to barcode individual cells with genes encoding fluorescent proteins. For genetic engineering, we utilize retroviral technology, which allows for the expression of ectopic genetic information in a stable manner in mammalian cells. We have genetically barcoded both adherent and nonadherent cells with different fluorescent proteins. Multiplexing power was increased by combining both the number of distinct fluorescent proteins, and the fluorescence intensity in each channel. Moreover, retroviral expression has proven to be stable for at least a 6-month period, which is critical for applications such as biological screens. We have shown the applicability of fluorescent barcoded multiplexing to cell-based assays that rely themselves on genetic barcoding, or on classical staining protocols. Fluorescent genetic barcoding gives the cell an inherited characteristic that distinguishes it from its counterpart. Once cell lines are developed, no further manipulation or staining is required, decreasing time, nonspecific background associated with staining protocols, and cost. The increasing number of discovered and/or engineered fluorescent proteins with unique absorbance/emission spectra, combined with the growing number of detection devices and lasers, increases multiplexing versatility, making fluorescent genetic barcoding a powerful tool for flow cytometry-based analysis. © 2013 International Society for Advancement of Cytometry.

  5. Non-radiographic intraoperative fluorescent cholangiography is feasible

    DEFF Research Database (Denmark)

    Larsen, Søren S; Schulze, Svend; Bisgaard, Thue

    2014-01-01

    INTRODUCTION: Intraoperative fluorescent cholangiography (IFC) with concomitant fluorescent angiography was recently developed for non-invasive identification of the anatomy during laparoscopic cholecystectomy. The objective of this study was to assess the time required for routine-use of IFC...... and to evaluate the success rate of the procedures. MATERIAL AND METHODS: A total of 35 patients scheduled for laparoscopic cholecystectomy and operated by the same surgeon were consecutively enrolled. A standardised protocol with IFC including angiography was performed during laparoscopic cholecystectomy...... hepatic duct was identified by IFC in all patients. In 29 of the 35 patients (83%; 95% confidence interval: 71-96%), the cystic artery was visualised by fluorescent angiography. No adverse effects or complications were recorded. CONCLUSION: Routine-use of IFC with fluorescent angiography during...

  6. Fluorescing macerals from wood precursors

    Energy Technology Data Exchange (ETDEWEB)

    Stout, S A; Bensley, D F

    1987-01-01

    A preliminary investigation into the origin of wood-derived macerals has established the existence of autofluorescent maceral precursors in the secondary xylem of swamp-inhabiting plant species. The optical character and fluorescent properties of microtomed thin-sections of modern woods from the Florida Everglades and Okefenokee Swamp, Georgia are compared to the character and properties of their peatified equivalents from various Everglades and Okefenokee peat horizons and their lignitic equivalents from the Brandon lignite of Vermont and the Trail Ridge lignitic peat from northern Florida. The inherent fluorescence of woody cell walls is believed to be caused by lignin though other cell wall components may contribute. The fluorescence spectra for several wood and cell types had a ..gamma../sub m//sub a//sub x/ of 452 nm and Q value of 0.00. The color as observed in blue light and the spectral geometry as measured in UV light of peatified and lignitic woody cell walls (potential textinites) may change progressively during early coalification. Cell wall-derived maceral material is shown to maintain its fluorescing properties after being converted to a structureless material, perhaps a corpohuminite or humodetrinite precursor. Fluorescing xylem cell contents, such as condensed tannins or essential oils, can maintain the fluorescent character through early coalification. Xylem cell walls and xylem cell contents are shown to provide fluorescing progenitor materials which would not require subsequent infusion with 'lipid' materials to account for their fluorescence as phytoclast material or as macerals in coal. 35 references.

  7. Assessing Photosynthesis by Fluorescence Imaging

    Science.gov (United States)

    Saura, Pedro; Quiles, Maria Jose

    2011-01-01

    This practical paper describes a novel fluorescence imaging experiment to study the three processes of photochemistry, fluorescence and thermal energy dissipation, which compete during the dissipation of excitation energy in photosynthesis. The technique represents a non-invasive tool for revealing and understanding the spatial heterogeneity in…

  8. Time-resolved fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Gustavsson, Thomas; Mialocq, Jean-Claude

    2007-01-01

    This article addresses the evolution in time of light emitted by a molecular system after a brief photo-excitation. The authors first describe fluorescence from a photo-physical point of view and discuss the characterization of the excited state. Then, they explain some basic notions related to fluorescence characterization (lifetime and decays, quantum efficiency, so on). They present the different experimental methods and techniques currently used to study time-resolved fluorescence. They discuss basic notions of time resolution and spectral reconstruction. They briefly present some conventional methods: intensified Ccd cameras, photo-multipliers and photodiodes associated with a fast oscilloscope, and phase modulation. Other methods and techniques are more precisely presented: time-correlated single photon counting (principle, examples, and fluorescence lifetime imagery), streak camera (principle, examples), and optical methods like the Kerr optical effect (principle and examples) and fluorescence up-conversion (principle and theoretical considerations, examples of application)

  9. Spectral Neugebauer-based color halftone prediction model accounting for paper fluorescence.

    Science.gov (United States)

    Hersch, Roger David

    2014-08-20

    We present a spectral model for predicting the fluorescent emission and the total reflectance of color halftones printed on optically brightened paper. By relying on extended Neugebauer models, the proposed model accounts for the attenuation by the ink halftones of both the incident exciting light in the UV wavelength range and the emerging fluorescent emission in the visible wavelength range. The total reflectance is predicted by adding the predicted fluorescent emission relative to the incident light and the pure reflectance predicted with an ink-spreading enhanced Yule-Nielsen modified Neugebauer reflectance prediction model. The predicted fluorescent emission spectrum as a function of the amounts of cyan, magenta, and yellow inks is very accurate. It can be useful to paper and ink manufacturers who would like to study in detail the contribution of the fluorescent brighteners and the attenuation of the fluorescent emission by ink halftones.

  10. Developing DNA nanotechnology using single-molecule fluorescence.

    Science.gov (United States)

    Tsukanov, Roman; Tomov, Toma E; Liber, Miran; Berger, Yaron; Nir, Eyal

    2014-06-17

    CONSPECTUS: An important effort in the DNA nanotechnology field is focused on the rational design and manufacture of molecular structures and dynamic devices made of DNA. As is the case for other technologies that deal with manipulation of matter, rational development requires high quality and informative feedback on the building blocks and final products. For DNA nanotechnology such feedback is typically provided by gel electrophoresis, atomic force microscopy (AFM), and transmission electron microscopy (TEM). These analytical tools provide excellent structural information; however, usually they do not provide high-resolution dynamic information. For the development of DNA-made dynamic devices such as machines, motors, robots, and computers this constitutes a major problem. Bulk-fluorescence techniques are capable of providing dynamic information, but because only ensemble averaged information is obtained, the technique may not adequately describe the dynamics in the context of complex DNA devices. The single-molecule fluorescence (SMF) technique offers a unique combination of capabilities that make it an excellent tool for guiding the development of DNA-made devices. The technique has been increasingly used in DNA nanotechnology, especially for the analysis of structure, dynamics, integrity, and operation of DNA-made devices; however, its capabilities are not yet sufficiently familiar to the community. The purpose of this Account is to demonstrate how different SMF tools can be utilized for the development of DNA devices and for structural dynamic investigation of biomolecules in general and DNA molecules in particular. Single-molecule diffusion-based Förster resonance energy transfer and alternating laser excitation (sm-FRET/ALEX) and immobilization-based total internal reflection fluorescence (TIRF) techniques are briefly described and demonstrated. To illustrate the many applications of SMF to DNA nanotechnology, examples of SMF studies of DNA hairpins and

  11. Females are the brighter sex: Differences in external fluorescence across sexes and life stages of a crab spider.

    Science.gov (United States)

    Brandt, Erin E; Masta, Susan E

    2017-01-01

    Fluorescence is increasingly recognized to be widespread in nature. In particular, some arachnids fluoresce externally, and in spiders the hemolymph fluoresces. In this study, we examined the external fluorescence and the fluorophores of different sexes and life stages of the crab spider Misumena vatia (Clerk 1757), a sit-and-wait predator that feeds on insects as they visit flowers. We designed novel instrumentation to measure external fluorescence in whole specimens. We found that although males and females possess internal fluorophores with similar properties, the external expression of fluorescence varies across sexes and life stages. Spiders fluoresce brightly as immatures. Females maintain their brightness to adulthood, whereas males become increasingly dim as they mature. We suggest that external fluorescence likely contributes to visual signaling in these animals, and that it differs between the sexes as a result of differences in foraging ecology and behavior.

  12. Females are the brighter sex: Differences in external fluorescence across sexes and life stages of a crab spider.

    Directory of Open Access Journals (Sweden)

    Erin E Brandt

    Full Text Available Fluorescence is increasingly recognized to be widespread in nature. In particular, some arachnids fluoresce externally, and in spiders the hemolymph fluoresces. In this study, we examined the external fluorescence and the fluorophores of different sexes and life stages of the crab spider Misumena vatia (Clerk 1757, a sit-and-wait predator that feeds on insects as they visit flowers. We designed novel instrumentation to measure external fluorescence in whole specimens. We found that although males and females possess internal fluorophores with similar properties, the external expression of fluorescence varies across sexes and life stages. Spiders fluoresce brightly as immatures. Females maintain their brightness to adulthood, whereas males become increasingly dim as they mature. We suggest that external fluorescence likely contributes to visual signaling in these animals, and that it differs between the sexes as a result of differences in foraging ecology and behavior.

  13. Fluorescence Behavior and Dural Infiltration of Meningioma Analyzed by 5-Aminolevulinic Acid-Based Fluorescence: Operating Microscope Versus Mini-Spectrometer.

    Science.gov (United States)

    Knipps, Johannes; Beseoglu, Kerim; Kamp, Marcel; Fischer, Igor; Felsberg, Joerg; Neumann, Lisa M; Steiger, Hans-Jakob; Cornelius, Jan F

    2017-12-01

    To compare fluorescence intensity of tumor specimens, as measured by a fluorescence-guided surgery microscope and a spectrometer, to evaluate tumor infiltration of dura mater around meningiomas with help of these 2 different 5-aminolevulinic acid (5-ALA)-based fluorescence tools, and to correlate fluorescence intensity with histopathologic data. In a clinical series, meningiomas were resected by 5-ALA fluorescence-guided surgery. Fluorescence intensity was semiquantitatively rated by the surgeon at predefined points. Biopsies were harvested and fluorescence intensity measured by a spectrometer and histopathologically analyzed. Sampling was realized at the level of the dura in a centrifugal direction. A total of 104 biopsies (n = 13 tumors) were analyzed. Specificity and sensitivity of the microscope were 0.96 and 0.53 and of the spectrometer 0.95 and 0.93, respectively. Fluorescence intensity as measured by the spectrometer was correlated to histologically confirmed tumor burden. In a centrifugal direction, tumor burden and fluorescence intensity continuously decreased (along the dural tail). Below a threshold value of 639 arbitrary units no tumor was histologically detectable. At the level of the dura the spectrometer was highly sensitive for detection of meningioma cells. The surgical microscope showed false negative results and missed residual tumor cells in more than one half of the cases. The complementary use of both fluorescence tools may improve resection quality. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Instant live-cell super-resolution imaging of cellular structures by nanoinjection of fluorescent probes.

    Science.gov (United States)

    Hennig, Simon; van de Linde, Sebastian; Lummer, Martina; Simonis, Matthias; Huser, Thomas; Sauer, Markus

    2015-02-11

    Labeling internal structures within living cells with standard fluorescent probes is a challenging problem. Here, we introduce a novel intracellular staining method that enables us to carefully control the labeling process and provides instant access to the inner structures of living cells. Using a hollow glass capillary with a diameter of <100 nm, we deliver functionalized fluorescent probes directly into the cells by (di)electrophoretic forces. The label density can be adjusted and traced directly during the staining process by fluorescence microscopy. We demonstrate the potential of this technique by delivering and imaging a range of commercially available cell-permeable and nonpermeable fluorescent probes to cells.

  15. Single Molecule Spectroscopy of Fluorescent Proteins

    NARCIS (Netherlands)

    Blum, Christian; Subramaniam, Vinod

    2009-01-01

    The discovery and use of fluorescent proteins has revolutionized cellular biology. Despite the widespread use of visible fluorescent proteins as reporters and sensors in cellular environments the versatile photophysics of fluorescent proteins is still subject to intense research. Understanding the

  16. Fluorescent multiplex cell flow systems and methods

    KAUST Repository

    Merzaban, Jasmeen; Abuelela, Ayman F.; Mohammad, Amal Jehad

    2017-01-01

    scanning system emits multiple electromagnetic wavelengths simultaneously it cause multiple fluorescent labels having different excitation wavelength maximums to fluoresce. The system can simultaneously capture real-time fluorescence images from at least

  17. International Trade. International Business

    OpenAIRE

    Мохнюк, А. М.; Mokhniuk, A. M.

    2015-01-01

    Work programme of the study course “International Trade. International Business” was prepared in accordance with educational and vocational training program for bachelors of training direction 6.030601 “Management”.

  18. Total parenteral nutrition - infants

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007239.htm Total parenteral nutrition - infants To use the sharing features on this page, please enable JavaScript. Total parenteral nutrition (TPN) is a method of feeding that bypasses ...

  19. Total parenteral nutrition

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000177.htm Total parenteral nutrition To use the sharing features on this page, please enable JavaScript. Total parenteral nutrition (TPN) is a method of feeding that bypasses ...

  20. Technique of total thyroidectomy

    International Nuclear Information System (INIS)

    Rao, R.S.

    1999-01-01

    It is essential to define the various surgical procedures that are carried out for carcinoma of the thyroid gland. They are thyroid gland, subtotal lobectomy, total thyroidectomy and near total thyroidectomy

  1. Total iron binding capacity

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003489.htm Total iron binding capacity To use the sharing features on this page, please enable JavaScript. Total iron binding capacity (TIBC) is a blood test to ...

  2. Impact of fluorescent protein fusions on the bacterial flagellar motor.

    Science.gov (United States)

    Heo, M; Nord, A L; Chamousset, D; van Rijn, E; Beaumont, H J E; Pedaci, F

    2017-10-03

    Fluorescent fusion proteins open a direct and unique window onto protein function. However, they also introduce the risk of perturbation of the function of the native protein. Successful applications of fluorescent fusions therefore rely on a careful assessment and minimization of the side effects, but such insight is still lacking for many applications. This is particularly relevant in the study of the internal dynamics of motor proteins, where both the chemical and mechanical reaction coordinates can be affected. Fluorescent proteins fused to the stator of the Bacterial Flagellar Motor (BFM) have previously been used to unveil the motor subunit dynamics. Here we report the effects on single motors of three fluorescent proteins fused to the stators, all of which altered BFM behavior. The torque generated by individual stators was reduced while their stoichiometry remained unaffected. MotB fusions decreased the switching frequency and induced a novel bias-dependent asymmetry in the speed in the two directions. These effects could be mitigated by inserting a linker at the fusion point. These findings provide a quantitative account of the effects of fluorescent fusions to the stator on BFM dynamics and their alleviation- new insights that advance the use of fluorescent fusions to probe the dynamics of protein complexes.

  3. Carbon "Quantum" Dots for Fluorescence Labeling of Cells.

    Science.gov (United States)

    Liu, Jia-Hui; Cao, Li; LeCroy, Gregory E; Wang, Ping; Meziani, Mohammed J; Dong, Yiyang; Liu, Yuanfang; Luo, Pengju G; Sun, Ya-Ping

    2015-09-02

    The specifically synthesized and selected carbon dots of relatively high fluorescence quantum yields were evaluated in their fluorescence labeling of cells. For the cancer cell lines, the cellular uptake of the carbon dots was generally efficient, resulting in the labeling of the cells with bright fluorescence emissions for both one- and two-photon excitations from predominantly the cell membrane and cytoplasm. In the exploration on labeling the live stem cells, the cellular uptake of the carbon dots was relatively less efficient, though fluorescence emissions could still be adequately detected in the labeled cells, with the emissions again predominantly from the cell membrane and cytoplasm. This combined with the observed more efficient internalization of the same carbon dots by the fixed stem cells might suggest some significant selectivity of the stem cells toward surface functionalities of the carbon dots. The needs and possible strategies for more systematic and comparative studies on the fluorescence labeling of different cells, including especially live stem cells, by carbon dots as a new class of brightly fluorescent probes are discussed.

  4. X-ray fluorescence beamline at LNLS: components and some associated techniques

    International Nuclear Information System (INIS)

    Perez, CArlos A.; Radtke, Martin; Perez, Carlos; Tolentino, Helio; Vicentin, Flavio; Sanchez, Hector Jorge; Perez, Roberto D.

    1997-01-01

    Full text. In this work a general description of the Total Reflection X-Ray Fluorescence (TXRF) and the X-Ray Fluorescence Microprobe (XRFM) is presented. Components, equipment and experimental stations for the x-ray fluorescence beamline are described, regarding to the techniques mentioned above. Results from the simulations of a pair bended mirrors in a Kirkpatrick-Baez configuration, are shown. The simulations were performed with Shadow program. (author)

  5. Smartphone microendoscopy for high resolution fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Xiangqian Hong

    2016-09-01

    Full Text Available High resolution optical endoscopes are increasingly used in diagnosis of various medical conditions of internal organs, such as the cervix and gastrointestinal (GI tracts, but they are too expensive for use in resource-poor settings. On the other hand, smartphones with high resolution cameras and Internet access have become more affordable, enabling them to diffuse into most rural areas and developing countries in the past decade. In this paper, we describe a smartphone microendoscope that can take fluorescence images with a spatial resolution of 3.1 μm. Images collected from ex vivo, in vitro and in vivo samples using the device are also presented. The compact and cost-effective smartphone microendoscope may be envisaged as a powerful tool for detecting pre-cancerous lesions of internal organs in low and middle-income countries (LMICs.

  6. Diffuse fluorescence tomography of exo- and endogenously labeled tumors

    Science.gov (United States)

    Balalaeva, Irina V.; Turchin, Ilya V.; Orlova, Anna G.; Plekhanov, Vladimir I.; Shirmanova, Marina V.; Kleshnin, Michail S.; Fiks, Ilya I.; Zagainova, Elena V.; Kamensky, Vladislav A.

    2007-06-01

    Strong light scattering and absorption limit observation of the internal structure of biological tissue. Only special tools for turbid media imaging, such as optical diffuse tomography, enable noninvasive investigation of the internal biological tissues, including visualization and intravital monitoring of deep tumors. In this work the preliminary results of diffuse fluorescence tomography (DFT) of small animals are presented. Usage of exogenous fluorophores, targeted specifically at tumor cells, and fluorescent proteins expressed endogenously can significantly increase the contrast of obtained images. Fluorescent compounds of different nature, such as sulphonated aluminium phthalocyanine (Photosens), red fluorescing proteins and CdTe/CdSe-core/shell nanocrystals (quantum dots) were applied. We tested diffuse fluorescence tomography method at model media, in post mortem and in vivo experiments. The animal was scanned in transilluminative configuration by low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at wavelength of 532 nm or semiconductor laser at wavelength of 655 nm. Quantum dots or protein DsRed2 in glass capsules (inner diameter 2-3 mm) were placed post mortem inside the esophagus of 7-day-old hairless rats to simulate marked tumors. Photosens was injected intravenously to linear mice with metastazing Lewis lung carcinoma. The reconstruction algorithm, based on Algebraic Reconstruction Technique, was created and tested numerically in model experiments. High contrast images of tumor simulating capsules with DsRed2 concentrations about 10 -6 M and quantum dots about 5x10 -11 M have been obtained. Organ distribution of Photosens and its accumulation in tumors and surrounding tissues of animals has been examined. We have conducted the monitoring of tumors, exogenously labeled by photosensitizer. This work demonstrates potential capabilities of DFT method for intravital detection and monitoring of deep fluorescent

  7. Total well dominated trees

    DEFF Research Database (Denmark)

    Finbow, Arthur; Frendrup, Allan; Vestergaard, Preben D.

    cardinality then G is a total well dominated graph. In this paper we study composition and decomposition of total well dominated trees. By a reversible process we prove that any total well dominated tree can both be reduced to and constructed from a family of three small trees....

  8. Capacity of X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Wobrauschek, P.; Kregsamer, P.

    1997-01-01

    X-Ray fluorescence analysis (XRF) is a powerful analytical tool for the qualitative and quantitative determination of chemical elements in a sample. Two different detection principles are accepted widely: wavelength dispersive and energy dispersive. Various sources for XRF are discussed: X-ray tubes, accelerators for particle induced XRF, radioactive isotopes, and the use of synchrotron radiation. Applications include environmental, technical, medical, fine art, and forensic studies. Due to the demands of research and application special techniques like total reflection XRF (TXRF) were developed with ultimately achievable detection limits in the femtogram region. The elements detectable by XRF range from Be to U. (author)

  9. Fluorescent standards for photodynamic therapy

    Science.gov (United States)

    Belko, N.; Kavalenka, S.; Samtsov, M.

    2016-08-01

    Photodynamic therapy is an evolving technique for treatment of various oncological diseases. This method employs photosensitizers - species that lead to death of tumor cells after the photoactivation. For further development and novel applications of photodynamic therapy new photosensitizers are required. After synthesis of a new photosensitizer it is important to know its concentration in different biological tissues after its administration and distribution. The concentration is frequently measured by the extraction method, which has some disadvantages, e.g. it requires many biological test subjects that are euthanized during the measurement. We propose to measure the photosensitizer concentration in tissue by its fluorescence. For this purpose fluorescent standards were developed. The standards are robust and simple to produce; their fluorescence signal does not change with time. The fluorescence intensity of fluorescent standards seems to depend linearly on the dye concentration. A set of standards thus allow the calibration of a spectrometer. Finally, the photosensitizer concentration can be determined by the fluorescence intensity after comparing the corresponding spectrum with spectra of the set of fluorescent standards. A biological test subject is not euthanized during this kind of experiment. We hope this more humane technique can be used in future instead of the extraction method.

  10. Fluorescence molecular tomography in the presence of background fluorescence

    International Nuclear Information System (INIS)

    Soubret, Antoine; Ntziachristos, Vasilis

    2006-01-01

    Fluorescence molecular tomography is an emerging imaging technique that resolves the bio-distribution of engineered fluorescent probes developed for in vivo reporting of specific cellular and sub-cellular targets. The method can detect fluorochromes in picomole amounts or less, imaged through entire animals, but the detection sensitivity and imaging performance drop in the presence of background, non-specific fluorescence. In this study, we carried out a theoretical and an experimental investigation on the effect of background fluorescence on the measured signal and on the tomographic reconstruction. We further examined the performance of three subtraction methods based on physical models of photon propagation, using experimental data on phantoms and small animals. We show that the data pre-processing with subtraction schemes can improve image quality and quantification when non-specific background florescence is present

  11. Effect of Xenon Anesthesia Compared to Sevoflurane and Total Intravenous Anesthesia for Coronary Artery Bypass Graft Surgery on Postoperative Cardiac Troponin Release: An International, Multicenter, Phase 3, Single-blinded, Randomized Noninferiority Trial.

    Science.gov (United States)

    Hofland, Jan; Ouattara, Alexandre; Fellahi, Jean-Luc; Gruenewald, Matthias; Hazebroucq, Jean; Ecoffey, Claude; Joseph, Pierre; Heringlake, Matthias; Steib, Annick; Coburn, Mark; Amour, Julien; Rozec, Bertrand; Liefde, Inge de; Meybohm, Patrick; Preckel, Benedikt; Hanouz, Jean-Luc; Tritapepe, Luigi; Tonner, Peter; Benhaoua, Hamina; Roesner, Jan Patrick; Bein, Berthold; Hanouz, Luc; Tenbrinck, Rob; Bogers, Ad J J C; Mik, Bert G; Coiffic, Alain; Renner, Jochen; Steinfath, Markus; Francksen, Helga; Broch, Ole; Haneya, Assad; Schaller, Manuella; Guinet, Patrick; Daviet, Lauren; Brianchon, Corinne; Rosier, Sebastien; Lehot, Jean-Jacques; Paarmann, Hauke; Schön, Julika; Hanke, Thorsten; Ettel, Joachym; Olsson, Silke; Klotz, Stefan; Samet, Amir; Laurinenas, Giedrius; Thibaud, Adrien; Cristinar, Mircea; Collanges, Olivier; Levy, François; Rossaint, Rolf; Stevanovic, Ana; Schaelte, Gereon; Stoppe, Christian; Hamou, Nora Ait; Hariri, Sarah; Quessard, Astrid; Carillion, Aude; Morin, Hélène; Silleran, Jacqueline; Robert, David; Crouzet, Anne-Sophie; Zacharowski, Kai; Reyher, Christian; Iken, Sonja; Weber, Nina C; Hollmann, Marcus; Eberl, Susanne; Carriero, Giovanni; Collacchi, Daria; Di Persio, Alessandra; Fourcade, Olivier; Bergt, Stefan; Alms, Angela

    2017-12-01

    Ischemic myocardial damage accompanying coronary artery bypass graft surgery remains a clinical challenge. We investigated whether xenon anesthesia could limit myocardial damage in coronary artery bypass graft surgery patients, as has been reported for animal ischemia models. In 17 university hospitals in France, Germany, Italy, and The Netherlands, low-risk elective, on-pump coronary artery bypass graft surgery patients were randomized to receive xenon, sevoflurane, or propofol-based total intravenous anesthesia for anesthesia maintenance. The primary outcome was the cardiac troponin I concentration in the blood 24 h postsurgery. The noninferiority margin for the mean difference in cardiac troponin I release between the xenon and sevoflurane groups was less than 0.15 ng/ml. Secondary outcomes were the safety and feasibility of xenon anesthesia. The first patient included at each center received xenon anesthesia for practical reasons. For all other patients, anesthesia maintenance was randomized (intention-to-treat: n = 492; per-protocol/without major protocol deviation: n = 446). Median 24-h postoperative cardiac troponin I concentrations (ng/ml [interquartile range]) were 1.14 [0.76 to 2.10] with xenon, 1.30 [0.78 to 2.67] with sevoflurane, and 1.48 [0.94 to 2.78] with total intravenous anesthesia [per-protocol]). The mean difference in cardiac troponin I release between xenon and sevoflurane was -0.09 ng/ml (95% CI, -0.30 to 0.11; per-protocol: P = 0.02). Postoperative cardiac troponin I release was significantly less with xenon than with total intravenous anesthesia (intention-to-treat: P = 0.05; per-protocol: P = 0.02). Perioperative variables and postoperative outcomes were comparable across all groups, with no safety concerns. In postoperative cardiac troponin I release, xenon was noninferior to sevoflurane in low-risk, on-pump coronary artery bypass graft surgery patients. Only with xenon was cardiac troponin I release less than with total intravenous

  12. RNA signal amplifier circuit with integrated fluorescence output.

    Science.gov (United States)

    Akter, Farhima; Yokobayashi, Yohei

    2015-05-15

    We designed an in vitro signal amplification circuit that takes a short RNA input that catalytically activates the Spinach RNA aptamer to produce a fluorescent output. The circuit consists of three RNA strands: an internally blocked Spinach aptamer, a fuel strand, and an input strand (catalyst), as well as the Spinach aptamer ligand 3,5-difluoro-4-hydroxylbenzylidene imidazolinone (DFHBI). The input strand initially displaces the internal inhibitory strand to activate the fluorescent aptamer while exposing a toehold to which the fuel strand can bind to further displace and recycle the input strand. Under a favorable condition, one input strand was able to activate up to five molecules of the internally blocked Spinach aptamer in 185 min at 30 °C. The simple RNA circuit reported here serves as a model for catalytic activation of arbitrary RNA effectors by chemical triggers.

  13. A portable fluorescence microscopic imaging system for cholecystectomy

    Science.gov (United States)

    Ye, Jian; Yang, Chaoyu; Gan, Qi; Ma, Rong; Zhang, Zeshu; Chang, Shufang; Shao, Pengfei; Zhang, Shiwu; Liu, Chenhai; Xu, Ronald

    2016-03-01

    In this paper we proposed a portable fluorescence microscopic imaging system to prevent iatrogenic biliary injuries from occurring during cholecystectomy due to misidentification of the cystic structures. The system consisted of a light source module, a CMOS camera, a Raspberry Pi computer and a 5 inch HDMI LCD. Specifically, the light source module was composed of 690 nm and 850 nm LEDs, allowing the CMOS camera to simultaneously acquire both fluorescence and background images. The system was controlled by Raspberry Pi using Python programming with the OpenCV library under Linux. We chose Indocyanine green(ICG) as a fluorescent contrast agent and then tested fluorescence intensities of the ICG aqueous solution at different concentration levels by our fluorescence microscopic system compared with the commercial Xenogen IVIS system. The spatial resolution of the proposed fluorescence microscopic imaging system was measured by a 1951 USAF resolution target and the dynamic response was evaluated quantitatively with an automatic displacement platform. Finally, we verified the technical feasibility of the proposed system in mouse models of bile duct, performing both correct and incorrect gallbladder resection. Our experiments showed that the proposed system can provide clear visualization of the confluence between the cystic duct and common bile duct or common hepatic duct, suggesting that this is a potential method for guiding cholecystectomy. The proposed portable system only cost a total of $300, potentially promoting its use in resource-limited settings.

  14. Instructive for disposal of fluorescent

    International Nuclear Information System (INIS)

    Salazar Vargas, Gerlin

    2014-01-01

    An instructive is established for the management system of waste fluorescent lamps, ensuring the storage, collection, transportation, and final disposal. The lamp is changed by an official of the Seccion de Matenimiento Construccion of the Oficina de Servicios Generales or is produced with the support of an official of the unit. The fluorescent should be deposited in stock of materials of the building maintenance section or unit specified with the help of a staff and in appropriate conditions. The fluorescent lamp is transported according to the guidelines in the manual. A responsible company is contracted by la Vicerrectoria de Administracion of the Universidad de Costa Rica dedicated to the transport and proper handling of fluorescent lamps [es

  15. ANTAGONISTIC POTENTIAL OF FLUORESCENT Pseudomonas ...

    African Journals Online (AJOL)

    Prof. Adipala Ekwamu

    GROWTH OF TOMATO CHALLENGED WITH PHTOPATHOGENS ... This study focused on the antagonistic potential of fluorescent Pseudomonas in vitro, and its inoculation effect on growth .... the 5 days old culture in starch agar with Lugol's.

  16. The effects of visual fluorescence marking induced by 5-aminolevulinic acid for endoscopic diagnosis of urinary bladder cancer

    Science.gov (United States)

    Daniltchenko, Dmitri I.; Koenig, Frank; Schnorr, Dietmar; Valdman, Alexander; Al-Shukri, Salman; Loening, Stefan A.

    2003-10-01

    During cystoscopy procedure, fluorescence diagnostics induced by 5-ALA improves visual detection of the bladder cancer. Macroscopic ALA-fluorescence allows visualizing of small flat tumors, carcinoma in situ, true neoplasm margins and dysplasias of the bladder. Following ALA instillation, cystoscopy has been performed under both standard and blue light illumination. Totally, 153 biopsies have been carried out at 53 patients with suspicion of bladder cancer. The results were compared to ALA-fluorescence data. In 13% of the patients, bladder cancer and dysplasia were found out in addition, due to red fluorescence. The sensitivity and specificity of ALA-fluorescence technique aggregated 96% and 52% respectively. The sensitivity and specificity of 5-ALA-fluorescent detection exceeded standard endoscopy under white light on 20%. The new method does not exclude a false positive and a false negative fluorescent luminescence. The ALA-based fluorescence detection system enhances the diagnosis of malignant/dysplastic bladder lesions significantly.

  17. X-ray fluorescence holography

    CERN Document Server

    Hayashi, K; Takahashi, Y

    2003-01-01

    X-ray fluorescence holography (XFH) is a new structural analysis method of determining a 3D atomic arrangement around fluorescing atoms. We developed an XFH apparatus using advanced X-ray techniques and succeeded in obtaining high-quality hologram data. Furthermore, we introduced applications to the structural analysis of a thin film and the environment around dopants and, discussed the quantitative analysis of local lattice distortion. (author)

  18. Colorful packages : fluorescent proteins in complex coacervate core micelles

    NARCIS (Netherlands)

    Nolles, Antsje

    2018-01-01

    This thesis explores the encapsulation of fluorescent proteins (FPs) into complex coacervate core micelles (C3Ms) and features the impact of this encapsulation on the biophysical properties of the FPs. In total eight different FPs were investigated originating from two different classes

  19. Fluorescent Nanodiamonds in Biomedical Applications.

    Science.gov (United States)

    Mitura, Katarzyna Anna; Włodarczyk, Elżbieta

    2018-04-18

    Nanoparticles have an extended surface and a large surface area, which is the ratio of the size of the surfacearea to the volume. A functionalized surface can give rise to more modifications and therefore allows this nanomaterial to have new properties. Fluorescent molecules contain fluorophore, which is capable of being excited via the absorption of light energy at a specific wavelength and subsequently emitting radiation energy of a longer wavelength. A chemically modified surface of nanodiamond (ND; by carboxylation) demonstrated biocompatibility with DNA, cytochrome C, and antigens. In turn, fluorescent nanodiamonds (FNDs) belong to a group of new nanomaterials. Their surface can be modified by joining functional groups such as carboxyl, hydroxyl, or amino, after which they can be employed as a fluorescence agent. Their fluorescent properties result from defects in the crystal lattice. FNDs reach dimensions of 4-100 nm, have attributes such as photostability, long fluorescence lifetimes (10 ns), and fluorescence emission between 600 and 700 nm. They are also nontoxic, chemically inert, biocompatible, and environmentally harmless. The main purpose of this article was to present the medical applications of various types of modified NDs.

  20. Fluorescence detection of esophageal neoplasia

    Science.gov (United States)

    Borisova, E.; Vladimirov, B.; Avramov, L.

    2008-06-01

    White-light endoscopy is well-established and wide used modality. However, despite the many technological advances that have been occurred, conventional endoscopy is suboptimal and usually detects advanced stage lesions. The limitations of standard endoscopy initiate development of spectroscopic techniques, additional to standard endoscopic equipment. One of the most sensitive approaches is fluorescence spectroscopy of gastrointestinal mucosa for neoplasia detection. In the recent study delta-aminolevulinic acid/Protoporphyrin IX (5-ALA/PpIX) is used as fluorescent marker for dysplasia and tumor detection in esophagus. The 5-ALA is administered per os six hours before measurements at dose 20 mg/kg weight. Excitation source has max of emission at 405 nm and light is delivered by the standard light guide of the endoscopic equipment. Through endoscopic instrumental channel a fiber is applied to return information about fluorescence to microspectrometer. Spectral features observed during endoscopic investigations could be distinct as the next regions: 450-630 nm region, where tissue autofluorescence is observed; 630-710 nm region, where fluorescence of PpIX is clearly pronounced; 530-580 nm region, where minima in the autofluorescence signal are observed, related to reabsorption of blood. The lack of fluorescence peaks in the red spectral area for normal mucosa is an indication for selective accumulation of 5-ALA/PpIX only in abnormal sites Very good correlation between fluorescence signals and histology examination of the lesions investigated is achieved.

  1. Study on fluorescence of Maillard reaction compounds in breakfast cereals.

    Science.gov (United States)

    Delgado-Andrade, Cristina; Rufián-Henares, José A; Morales, Francisco J

    2006-09-01

    During the advanced stage of the Maillard reaction (MR) in food processing and cooking, Amadori rearrangement products undergo dehydration and fission and fluorescent substances are formed. Free and total (free + linked to the protein backbone) fluorescence (FIC) due to Maillard compounds in 60 commercial breakfast cereals was evaluated. Pronase was used for efficient release of linked fluorescent Maillard compounds from the protein backbone. Results were correlated with some heat-induced markers of the extent of the MR or sugar caramelisation during cereal processing, such as hydroxymethylfurfural, furfural, glucosilisomaltol and furosine. The effect of sample composition (dietary-fibre added, protein, etc.) on levels of FIC, expressed as fluorescence intensity (FI) per milligram of sample, is discussed. FIC is significantly correlated to the protein content of the sample and fluorescent Maillard compounds are mainly linked to the protein backbone. The ratio of total-FIC to free-FIC was 10.4-fold for corn-based, wheat-based and multicereal-based breakfast cereals but significantly higher in rice-based samples. Addition of dietary fibre or honey increased the FIC values. Data support the usefulness of FIC measurement as an unspecific heat-induced marker in breakfast cereals.

  2. Compact point-detection fluorescence spectroscopy system for quantifying intrinsic fluorescence redox ratio in brain cancer diagnostics

    Science.gov (United States)

    Liu, Quan; Grant, Gerald; Li, Jianjun; Zhang, Yan; Hu, Fangyao; Li, Shuqin; Wilson, Christy; Chen, Kui; Bigner, Darell; Vo-Dinh, Tuan

    2011-03-01

    We report the development of a compact point-detection fluorescence spectroscopy system and two data analysis methods to quantify the intrinsic fluorescence redox ratio and diagnose brain cancer in an orthotopic brain tumor rat model. Our system employs one compact cw diode laser (407 nm) to excite two primary endogenous fluorophores, reduced nicotinamide adenine dinucleotide, and flavin adenine dinucleotide. The spectra were first analyzed using a spectral filtering modulation method developed previously to derive the intrinsic fluorescence redox ratio, which has the advantages of insensitivty to optical coupling and rapid data acquisition and analysis. This method represents a convenient and rapid alternative for achieving intrinsic fluorescence-based redox measurements as compared to those complicated model-based methods. It is worth noting that the method can also extract total hemoglobin concentration at the same time but only if the emission path length of fluorescence light, which depends on the illumination and collection geometry of the optical probe, is long enough so that the effect of absorption on fluorescence intensity due to hemoglobin is significant. Then a multivariate method was used to statistically classify normal tissues and tumors. Although the first method offers quantitative tissue metabolism information, the second method provides high overall classification accuracy. The two methods provide complementary capabilities for understanding cancer development and noninvasively diagnosing brain cancer. The results of our study suggest that this portable system can be potentially used to demarcate the elusive boundary between a brain tumor and the surrounding normal tissue during surgical resection.

  3. Enhancement of single-molecule fluorescence signals by colloidal silver nanoparticles in studies of protein translation.

    Science.gov (United States)

    Bharill, Shashank; Chen, Chunlai; Stevens, Benjamin; Kaur, Jaskiran; Smilansky, Zeev; Mandecki, Wlodek; Gryczynski, Ignacy; Gryczynski, Zygmunt; Cooperman, Barry S; Goldman, Yale E

    2011-01-25

    Metal-enhanced fluorescence (MEF) increased total photon emission of Cy3- and Cy5-labeled ribosomal initiation complexes near 50 nm silver particles 4- and 5.5-fold, respectively. Fluorescence intensity fluctuations above shot noise, at 0.1-5 Hz, were greater on silver particles. Overall signal-to-noise ratio was similar or slightly improved near the particles. Proximity to silver particles did not compromise ribosome function, as measured by codon-dependent binding of fluorescent tRNA, dynamics of fluorescence resonance energy transfer between adjacent tRNAs in the ribosome, and tRNA translocation induced by elongation factor G.

  4. Enhancement of Single Molecule Fluorescence Signals by Colloidal Silver Nanoparticles in Studies of Protein Translation

    Science.gov (United States)

    Bharill, Shashank; Chen, Chunlai; Stevens, Benjamin; Kaur, Jaskiran; Smilansky, Zeev; Mandecki, Wlodek; Gryczynski, Ignacy; Gryczynski, Zygmunt; Cooperman, Barry S.; Goldman, Yale E.

    2011-01-01

    Metal enhanced fluorescence (MEF) increased total photon emission of Cy3- and Cy5-labeled ribosomal initiation complexes near 50 nm silver particles 4- and 5.5-fold respectively. Fluorescence intensity fluctuations above shot noise, at 0.1 – 5 Hz, were greater on silver particles. Overall signal to noise ratio was similar or slightly improved near the particles. Proximity to silver particles did not compromise ribosome function, as measured by codon-dependent binding of fluorescent tRNA, dynamics of fluorescence resonance energy transfer between adjacent tRNAs in the ribosome, and tRNA translocation induced by elongation factor G. PMID:21158483

  5. Total Quality Leadership

    Science.gov (United States)

    1991-01-01

    More than 750 NASA, government, contractor, and academic representatives attended the Seventh Annual NASA/Contractors Conference on Quality and Productivity. The panel presentations and Keynote speeches revolving around the theme of total quality leadership provided a solid base of understanding of the importance, benefits, and principles of total quality management (TQM). The presentations from the conference are summarized.

  6. Genoptraening efter total knaealloplastik

    DEFF Research Database (Denmark)

    Holm, Bente; Kehlet, Henrik

    2009-01-01

    The short- and long-term benefits of post-discharge physiotherapy regimens after total knee arthroplasty are debatable. A national survey including hospitals in Denmark that perform total knee arthroplasty showed a large variability in indication and regimen for post-knee arthroplasty...

  7. Incapacidad laboral total

    Directory of Open Access Journals (Sweden)

    Orlando Díaz Tabares

    1997-04-01

    Full Text Available Se realizó un estudio longitudinal, descriptivo y retrospectivo con el objetivo de conocer el comportamiento de la incapacidad permanente para el trabajo en el municipio "San Cristóbal" durante el decenio 1982-1991, y se aplicó el método de encuesta por el que se recogieron datos que fueron extraídos del modelo oficial de peritaje médico laboral y de la entrevista con el peritado. Los resultados fueron plasmados en tablas de contingencias donde se relacionan las variables por cada año estudiado, y se aplicó la prueba estadística de chi cuadrado. El número de individuos dictaminados con incapacidad laboral total fue de 693; predominó en reportes el año 1988 con 114 casos y muy discretamente el sexo femenino sobre el masculino, el grupo etáreo de 45 a 54 años con 360 casos y la artrosis como entidad valorada por ortopedia, con análisis estadísticos significativos. No resultó estadísticamente significativo, el predominio de la hipertensión arterial sistémica entre las entidades valoradas por la especialidad de medicina interna como causas de incapacidad laboral. Fue muy significativa la variación del número de dictaminados por la comisión en cada uno de los años estudiados y que el porcentaje de ellos que se encontraban realizando trabajos que demandan esfuerzo físico de moderado a intenso al momento de aplicar la encuesta, ascendió al 64,9.A longitudinal, descriptive and retrospective study was conducted in order to know the behavior of permanent labor disability at the municipality of San Cristóbal during 1982-1991. A survey was done to collect data taken from the official model of medical inspections and from the interview with the disabled worker. The results were shown in contingency tables where the variables are related by every year studied. The chi square statistical test was applied. The number of individuals with labor disability was 693. As for reports, the year 1988 predominated with 114. There was a discreet

  8. FLUORESCENCE DIAGNOSIS FOR RECURRENT BLADDER CANCER

    Directory of Open Access Journals (Sweden)

    R. V. Ulyanov

    2017-01-01

    Full Text Available The clinical case of successful use of local fluorescence spectroscopy combined with fluorescence imaging during cystoscopy for diagnosis of recurrent bladder cancer is represented in the article. Histological study of fluorescent foci confirmed tumor growth (urothelial carcinoma in all areas with high levels of diagnostic parameter. In the fluorescent focus with low diagnostic parameter inflammation was detected.

  9. Quantitative analysis of fluorescence lifetime measurements of the macula using the fluorescence lifetime imaging ophthalmoscope in healthy subjects.

    Science.gov (United States)

    Dysli, Chantal; Quellec, Gwénolé; Abegg, Mathias; Menke, Marcel N; Wolf-Schnurrbusch, Ute; Kowal, Jens; Blatz, Johannes; La Schiazza, Olivier; Leichtle, Alexander B; Wolf, Sebastian; Zinkernagel, Martin S

    2014-04-03

    Fundus autofluorescence (FAF) cannot only be characterized by the intensity or the emission spectrum, but also by its lifetime. As the lifetime of a fluorescent molecule is sensitive to its local microenvironment, this technique may provide more information than fundus autofluorescence imaging. We report here the characteristics and repeatability of FAF lifetime measurements of the human macula using a new fluorescence lifetime imaging ophthalmoscope (FLIO). A total of 31 healthy phakic subjects were included in this study with an age range from 22 to 61 years. For image acquisition, a fluorescence lifetime ophthalmoscope based on a Heidelberg Engineering Spectralis system was used. Fluorescence lifetime maps of the retina were recorded in a short- (498-560 nm) and a long- (560-720 nm) spectral channel. For quantification of fluorescence lifetimes a standard ETDRS grid was used. Mean fluorescence lifetimes were shortest in the fovea, with 208 picoseconds for the short-spectral channel and 239 picoseconds for the long-spectral channel, respectively. Fluorescence lifetimes increased from the central area to the outer ring of the ETDRS grid. The test-retest reliability of FLIO was very high for all ETDRS areas (Spearman's ρ = 0.80 for the short- and 0.97 for the long-spectral channel, P macula in healthy subjects. By using a custom-built software, we were able to quantify fluorescence lifetimes within the ETDRS grid. Establishing a clinically accessible standard against which to measure FAF lifetimes within the retina is a prerequisite for future studies in retinal disease.

  10. Ultra-sensitive DNA assay based on single-molecule detection coupled with fluorescent quantum dot-labeling and its application to determination of messenger RNA

    International Nuclear Information System (INIS)

    Li Li; Li Xincang; Li Lu; Wang Jinxing; Jin Wenrui

    2011-01-01

    An ultra-sensitive single-molecule detection (SMD) method for quantification of DNA using total internal reflection fluorescence microscopy (TIRFM) coupled with fluorescent quantum dot (QD)-labeling was developed. In this method, the target DNA (tDNA) was captured by the capture DNA immobilized on the silanized coverslip blocked with ethanolamine and bovine serum albumin. Then, the QD-labeled probe DNA was hybridized to the tDNA. Ten fluorescent images of the QD-labeled sandwich DNA hybrids on the coverslip were taken by a high-sensitive CCD. The tDNA was quantified by counting the bright spots on the images using a calibration curve. The LOD of the method was 1 x 10 -14 mol L -1 . Several key factors, including image acquirement, fluorescence probe, substrate preparation, noise elimination from solutions and glass coverslips, and nonspecific adsorption and binding of solution-phase detection probes were discussed in detail. The method could be applied to quantify messenger RNA (mRNA) in cells. In order to determine mRNA, double-stranded RNA-DNA hybrids consisting of mRNA and corresponding cDNA were synthesized from the cellular mRNA template using reverse transcription in the presence of reverse transcriptase. After removing the mRNA in the double-stranded hybrids using ribonuclease, cDNA was quantified using the SMD-based TIRFM. Osteopontin mRNA in decidual stromal cells was chosen as the model analyte.

  11. Ultra-sensitive DNA assay based on single-molecule detection coupled with fluorescent quantum dot-labeling and its application to determination of messenger RNA

    Energy Technology Data Exchange (ETDEWEB)

    Li Li [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Li Xincang [School of Life Sciences, Shandong University, Jinan 250100 (China); Li Lu [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Wang Jinxing [School of Life Sciences, Shandong University, Jinan 250100 (China); Jin Wenrui, E-mail: jwr@sdu.edu.cn [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China)

    2011-01-24

    An ultra-sensitive single-molecule detection (SMD) method for quantification of DNA using total internal reflection fluorescence microscopy (TIRFM) coupled with fluorescent quantum dot (QD)-labeling was developed. In this method, the target DNA (tDNA) was captured by the capture DNA immobilized on the silanized coverslip blocked with ethanolamine and bovine serum albumin. Then, the QD-labeled probe DNA was hybridized to the tDNA. Ten fluorescent images of the QD-labeled sandwich DNA hybrids on the coverslip were taken by a high-sensitive CCD. The tDNA was quantified by counting the bright spots on the images using a calibration curve. The LOD of the method was 1 x 10{sup -14} mol L{sup -1}. Several key factors, including image acquirement, fluorescence probe, substrate preparation, noise elimination from solutions and glass coverslips, and nonspecific adsorption and binding of solution-phase detection probes were discussed in detail. The method could be applied to quantify messenger RNA (mRNA) in cells. In order to determine mRNA, double-stranded RNA-DNA hybrids consisting of mRNA and corresponding cDNA were synthesized from the cellular mRNA template using reverse transcription in the presence of reverse transcriptase. After removing the mRNA in the double-stranded hybrids using ribonuclease, cDNA was quantified using the SMD-based TIRFM. Osteopontin mRNA in decidual stromal cells was chosen as the model analyte.

  12. Three-dimensional in vivo fluorescence diffuse optical tomography of breast cancer in humans

    Science.gov (United States)

    Corlu, Alper; Choe, Regine; Durduran, Turgut; Rosen, Mark A.; Schweiger, Martin; Arridge, Simon R.; Schnall, Mitchell D.; Yodh, Arjun G.

    2007-05-01

    We present three-dimensional (3D) in vivo images of human breast cancer based on fluorescence diffuse optical tomography (FDOT). To our knowledge, this work represents the first reported 3D fluorescence tomography of human breast cancer in vivo. In our protocol, the fluorophore Indocyanine Green (ICG) is injected intravenously. Fluorescence excitation and detection are accomplished in the soft-compression, parallel-plane, transmission geometry using laser sources at 786 nm and spectrally filtered CCD detection. Phantom and in vivo studies confirm the signals are due to ICG fluorescence, rather than tissue autofluorescence and excitation light leakage. Fluorescence images of breast tumors were in good agreement with those of MRI, and with DOT based on endogenous contrast. Tumorto- normal tissue contrast based on ICG fluorescence was two-to-four-fold higher than contrast based on hemoglobin and scattering parameters. In total the measurements demonstrate that FDOT of breast cancer is feasible and promising.

  13. Fluorescence diffuse tomography for tumor detection and monitoring

    Science.gov (United States)

    Balalaeva, Irina V.; Orlova, Anna G.; Shirmanova, Marina V.; Kibraeva, Elena A.; Zagainova, Elena V.; Turchin, Ilya V.

    2007-05-01

    Strong light scattering and absorption limit visualization of the internal structure of biological tissue. Only special tools for turbid media imaging, such as optical diffuse tomography, enable noninvasive investigation of the internal biological tissues, including visualization and intravital monitoring of deep tumors. In this work the preliminary results of fluorescence diffuse tomography (FDT) of small animals are presented. Using of exogenous fluorophores, targeted specifically at tumor cells, and fluorescent proteins expressed endogenously can significantly increase the contrast of obtained images. Fluorescent compounds of different nature, such as sulphonated aluminium phthalocyanine (Photosens), red fluorescing proteins and CdTe/CdSe-core/shell nanocrystals (quantum dots) were applied. The animal was scanned in the transilluminative configuration by low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the wavelength of 532 nm or semiconductor laser at the wavelength of 655 nm. Photosens was injected intravenously into linear mice with metastazing Lewis lung carcinoma in dose 4 mg/kg. Quantum dots (5x10 -11 M) or protein DsRed2 (1-5x10 -6 M) in glass capsules (inner diameter 2-3 mm) were placed inside the esophagus of 7-day-old hairless rats (18-20 g) to simulate marked tumors. Cells of HEK-293 Phoenix line, transitory transfected with Turbo-RFP protein gene, were injected hypodermically to immunodeficient mice. This work demonstrates potential capabilities of FDT method for detection and monitoring of deep fluorescent-labeled tumors in animal models. Strong advantages of fluorescent proteins and quantum dots over the traditional photosensitizer for FDT imaging are shown.

  14. Correlates of Total Sedentary Time and Screen Time in 9-11 Year-Old Children around the World: The International Study of Childhood Obesity, Lifestyle and the Environment.

    Science.gov (United States)

    LeBlanc, Allana G; Katzmarzyk, Peter T; Barreira, Tiago V; Broyles, Stephanie T; Chaput, Jean-Philippe; Church, Timothy S; Fogelholm, Mikael; Harrington, Deirdre M; Hu, Gang; Kuriyan, Rebecca; Kurpad, Anura; Lambert, Estelle V; Maher, Carol; Maia, José; Matsudo, Victor; Olds, Timothy; Onywera, Vincent; Sarmiento, Olga L; Standage, Martyn; Tudor-Locke, Catrine; Zhao, Pei; Tremblay, Mark S

    2015-01-01

    Previously, studies examining correlates of sedentary behavior have been limited by small sample size, restricted geographic area, and little socio-cultural variability. Further, few studies have examined correlates of total sedentary time (SED) and screen time (ST) in the same population. This study aimed to investigate correlates of SED and ST in children around the world. The sample included 5,844 children (45.6% boys, mean age = 10.4 years) from study sites in Australia, Brazil, Canada, China, Colombia, Finland, India, Kenya, Portugal, South Africa, the United Kingdom, and the United States. Child- and parent-reported behavioral, household, and neighborhood characteristics and directly measured anthropometric and accelerometer data were obtained. Twenty-one potential correlates of SED and ST were examined using multilevel models, adjusting for sex, age, and highest parental education, with school and study site as random effects. Variables that were moderately associated with SED and/or ST in univariate analyses (pcomputer in the bedroom. In this global sample many common correlates of SED and ST were identified, some of which are easily modifiable (e.g., removing TV from the bedroom), and others that may require more intense behavioral interventions (e.g., increasing physical activity). Future work should incorporate these findings into the development of culturally meaningful public health messages.

  15. International Clean Energy System Using Hydrogen Conversion (WE-NET). subtask 3. Conceptual design of the total system; Suiso riyo kokusai clean energy system gijutsu (WE-NET). subtask 3. Zentai system gainen sekkei

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This paper describes the research result on the conceptual design of the total system for the WE-NET project in 1996. Basic conditions are as follows: solid polymer water electrolysis, hydrogen combustion turbine power generation, hydrogen transport/storage through ammonia medium, power generation scale of 1000-4000MW (2-5 yen/kWh), and transport distance of 5000-20000km between supply and consumption places. The system efficiency was estimated to be 68% and 23% at an ammonia arrival time and power sending end, respectively, and it was dependent on a transport distance, while no power generation scale. The power cost was estimated to be 7 yen/Mcal and 33 yen/kWh, respectively. The system efficiency at a sending end was lower by 15% and 2% than that of the liquid hydrogen and methanol system, while the power cost was higher by 0 and 8 yen/kWh, respectively. It was necessary for loss reduction of this ammonia system to develop a new high-efficiency ammonia synthesis process, and hydrogen separation (decomposition/refining) process. 80 figs., 52 tabs.

  16. Estonian total ozone climatology

    Directory of Open Access Journals (Sweden)

    K. Eerme

    Full Text Available The climatological characteristics of total ozone over Estonia based on the Total Ozone Mapping Spectrometer (TOMS data are discussed. The mean annual cycle during 1979–2000 for the site at 58.3° N and 26.5° E is compiled. The available ground-level data interpolated before TOMS, have been used for trend detection. During the last two decades, the quasi-biennial oscillation (QBO corrected systematic decrease of total ozone from February–April was 3 ± 2.6% per decade. Before 1980, a spring decrease was not detectable. No decreasing trend was found in either the late autumn ozone minimum or in the summer total ozone. The QBO related signal in the spring total ozone has an amplitude of ± 20 DU and phase lag of 20 months. Between 1987–1992, the lagged covariance between the Singapore wind and the studied total ozone was weak. The spring (April–May and summer (June–August total ozone have the best correlation (coefficient 0.7 in the yearly cycle. The correlation between the May and August total ozone is higher than the one between the other summer months. Seasonal power spectra of the total ozone variance show preferred periods with an over 95% significance level. Since 1986, during the winter/spring, the contribution period of 32 days prevails instead of the earlier dominating 26 days. The spectral densities of the periods from 4 days to 2 weeks exhibit high interannual variability.

    Key words. Atmospheric composition and structure (middle atmosphere – composition and chemistry; volcanic effects – Meteorology and atmospheric dynamics (climatology

  17. Total photon absorption

    International Nuclear Information System (INIS)

    Carlos, P.

    1985-06-01

    The present discussion is limited to a presentation of the most recent total photonuclear absorption experiments performed with real photons at intermediate energy, and more precisely in the region of nucleon resonances. The main sources of real photons are briefly reviewed and the experimental procedures used for total photonuclear absorption cross section measurements. The main results obtained below 140 MeV photon energy as well as above 2 GeV are recalled. The experimental study of total photonuclear absorption in the nuclear resonance region (140 MeV< E<2 GeV) is still at its beginning and some results are presented

  18. [Total artificial heart].

    Science.gov (United States)

    Antretter, H; Dumfarth, J; Höfer, D

    2015-09-01

    To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.

  19. Indirect Fluorescent Antibody Technique based Prevalence of Surra in Equines

    Directory of Open Access Journals (Sweden)

    Ahsan Nadeem, Asim Aslam*, Zafar Iqbal Chaudhary, Kamran Ashraf1, Khalid Saeed1, Nisar Ahmad1, Ishtiaq Ahmed and Habib ur Rehman2

    2011-04-01

    Full Text Available This project was carried out to find the prevalence of trypanosomiasis in equine in District Gujranwala by using indirect fluorescent antibody technique and thin smear method. Blood samples were collected from a total of 200 horses and donkeys of different ages and either sex. Duplicate thin blood smears were prepared from each sample and remaining blood samples were centrifuged to separate the serum. Smears from each animal were processed for giemsa staining and indirect fluorescent antibody test (IFAT. Giemsa stained smears revealed Trypanosome infection in 4/200 (2.0% samples and IFAT in 12/200 (6.0% animals.

  20. Time resolved fluorescenc