WorldWideScience

Sample records for total heart rate

  1. Heart rate index

    DEFF Research Database (Denmark)

    Haedersdal, C; Pedersen, F H; Svendsen, J H

    1992-01-01

    after the myocardial infarction. A significant correlation (Spearman's correlation coefficient rs, p less than 0.05) was found between LVEF at rest and the following variables assessed at exercise test: 1) the heart rate at rest, 2) rise in heart rate, 3) ratio between maximal heart rate and heart rate...... at rest, 4) rise in systolic blood pressure, 5) rate pressure product at rest, 6) rise in rate pressure product, 7) ratio (rHR) between maximal rate pressure product and rate pressure product at rest, 8) total exercise time. The heart rate was corrected for effects caused by age (heart index (HR...

  2. [Total artificial heart].

    Science.gov (United States)

    Antretter, H; Dumfarth, J; Höfer, D

    2015-09-01

    To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.

  3. The total artificial heart.

    Science.gov (United States)

    Cook, Jason A; Shah, Keyur B; Quader, Mohammed A; Cooke, Richard H; Kasirajan, Vigneshwar; Rao, Kris K; Smallfield, Melissa C; Tchoukina, Inna; Tang, Daniel G

    2015-12-01

    The total artificial heart (TAH) is a form of mechanical circulatory support in which the patient's native ventricles and valves are explanted and replaced by a pneumatically powered artificial heart. Currently, the TAH is approved for use in end-stage biventricular heart failure as a bridge to heart transplantation. However, with an increasing global burden of cardiovascular disease and congestive heart failure, the number of patients with end-stage heart failure awaiting heart transplantation now far exceeds the number of available hearts. As a result, the use of mechanical circulatory support, including the TAH and left ventricular assist device (LVAD), is growing exponentially. The LVAD is already widely used as destination therapy, and destination therapy for the TAH is under investigation. While most patients requiring mechanical circulatory support are effectively treated with LVADs, there is a subset of patients with concurrent right ventricular failure or major structural barriers to LVAD placement in whom TAH may be more appropriate. The history, indications, surgical implantation, post device management, outcomes, complications, and future direction of the TAH are discussed in this review.

  4. Heart rate monitoring mobile applications

    OpenAIRE

    Chaudhry, Beenish M.

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone?s camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, ?Unique Heart Rate Monitor?, you can also maintain your heart rate history for personal ...

  5. Heart rate monitoring mobile applications.

    Science.gov (United States)

    Chaudhry, Beenish M

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone's camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, 'Unique Heart Rate Monitor', you can also maintain your heart rate history for personal reflection and sharing with a provider.

  6. [Studies on the relationship between beta-adrenergic receptor density on cell wall lymphocytes, total serum catecholamine level and heart rate in patients with hyperthyroidism].

    Science.gov (United States)

    Gajek, J; Zieba, I; Zyśko, D

    2000-08-01

    Hyperthyreosis mimics the hyperadrenergic state and its symptoms were though to be dependent on increased level of catecholamines. Another reason for the symptoms could be the increased density or affinity of beta-adrenergic receptors to catecholamines. The aim of the study was to examine the elements of sympathetic nervous system, thyroid hormones level and their influence on heart rate control in patients with hyperthyreosis. The study was carried out in 18 women, mean age 48.9 +/- 8.7 yrs and 6 men, mean age 54.2 +/- 8.7 yrs. The control group consisted of 30 healthy persons matched for age and sex. We examined the density of beta-adrenergic receptors using radioligand labelling method with 125I-cyanopindolol, serum total catecholamines level with radioenzymatic assay kit, the levels of free thyroid hormones using radioimmunoassays and thyreotropine level with immunoradiometric assay. Maximal, minimal and mean heart rate were studied using Holter monitoring system. The density of beta-adrenergic receptors in hyperthyreosis was 37.3 +/- 21.7 vs 37.2 +/- 18.1 fmol/mg in the control group (p = NS). Total catecholamines level was significantly decreased in hyperthyreosis group: 1.5 +/- 0.89 vs 1.9 +/- 0.73 pmol/ml (p < 0.05). There was significantly higher minimal, maximal and mean heart rate in hyperthyreosis group (p < 0.0001, p < 0.0001 and p < 0.05 respectively). There was a weak inverse correlation between minimum heart rate and triiodothyronine level (r = -0.38, p < 0.05). An inverse correlation between triiodothyronine and catecholamines level (r = -0.49, p < 0.05) was observed. Beta-adrenergic receptors density is unchanged and catecholamines level is decreased in hyperthyreosis when compared to normal subjects. There is no correlation between minimal heart rate and adrenergic receptors density or catecholamines level in hyperthyreosis.

  7. Target Heart Rates

    Science.gov (United States)

    ... Check Recipe Certification Program Nutrition Requirements Heart-Check Professional Resources Contact the Heart-Check Certification Program Simple Cooking and Recipes Dining Out Choosing a Restaurant Deciphering ...

  8. Effect of selective and nonselective beta-blockers on resting energy production rate and total body substrate utilization in chronic heart failure.

    Science.gov (United States)

    Podbregar, Matej; Voga, Gorazd

    2002-12-01

    In chronic heart failure (CHF) beta-blockers reduce myocardial oxygen consumption and improve myocardial efficiency by shifting myocardial substrate utilization from increased free fatty acid oxidation to increased glucose oxidation. The effect of selective and nonselective beta-blockers on total body resting energy production rate (EPR) and substrate utilization is not known. Twenty-six noncachectic patients with moderately severe heart failure (New York Heart Association class II or III, left ventricular ejection fraction < 0.40) were treated with carvedilol (37.5 +/- 13.5 mg/12 h) or bisoprolol (5.4 +/- 3.0 mg/d) for 6 months. Indirect calorimetry was performed before and after 6 months of treatment. Resting EPR was decreased in carvedilol (5.021 +/- 0.803 to 4.552 +/- 0.615 kJ/min, P <.001) and bisoprolol group (5.230 +/- 0.828 to 4.978 +/- 0.640 kJ/min, P <.05; nonsignificant difference between groups). Lipid oxidation rate decreased in carvedilol and remained unchanged in bisoprolol group (2.4 +/- 1.4 to 1.5 +/- 0.9 mg m(2)/kg min versus 2.7 +/- 1.1 to 2.5 +/- 1.1 mg m(2)/kg min, P <.05). Glucose oxidation rate was increased only in carvedilol (2.6 +/- 1.4 to 4.4 +/- 1.6 mg m(2)/kg min, P <.05), but did not change in bisoprolol group. Both selective and nonselective beta-blockers reduce total body resting EPR in noncachectic CHF patients. Carvedilol compared to bisoprolol shifts total body substrate utilization from lipid to glucose oxidation.

  9. Airway Complications of Total Artificial Heart.

    Science.gov (United States)

    Pathak, Vikas; Donovan, Colin; Malhotra, Rajiv

    2017-02-01

    The total artificial heart is the mechanical device which is used as a bridge to the heart transplant in patients with biventricular failure. Due to the mechanical nature of the device, patients receiving total artificial heart (TAH) require to be on anticoagulation therapy. Hemorrhage and coagulopathy are few of the known complications of TAH.

  10. Neonatal heart rate prediction.

    Science.gov (United States)

    Abdel-Rahman, Yumna; Jeremic, Aleksander; Tan, Kenneth

    2009-01-01

    Technological advances have caused a decrease in the number of infant deaths. Pre-term infants now have a substantially increased chance of survival. One of the mechanisms that is vital to saving the lives of these infants is continuous monitoring and early diagnosis. With continuous monitoring huge amounts of data are collected with so much information embedded in them. By using statistical analysis this information can be extracted and used to aid diagnosis and to understand development. In this study we have a large dataset containing over 180 pre-term infants whose heart rates were recorded over the length of their stay in the Neonatal Intensive Care Unit (NICU). We test two types of models, empirical bayesian and autoregressive moving average. We then attempt to predict future values. The autoregressive moving average model showed better results but required more computation.

  11. The Effect of Music Listening on Pain, Heart Rate Variability, and Range of Motion in Older Adults After Total Knee Replacement.

    Science.gov (United States)

    Hsu, Chih-Chung; Chen, Su-Ru; Lee, Pi-Hsia; Lin, Pi-Chu

    2017-12-01

    The purpose of this study was to investigate the effects that listening and not listening to music had on pain relief, heart rate variability (HRV), and knee range of motion in total knee replacement (TKR) patients who underwent continuous passive motion (CPM) rehabilitation. We adopted a single-group quasi-experimental design. A sample of 49 TKR patients listened to music for 25 min during one session of CPM and no music during another session of CPM the same day for a total of 2 days. Results indicated that during CPM, patients exhibited a significant decrease in the pain level ( p listening to music compared with no music. This study demonstrated that listening to music can effectively decrease pain during CPM rehabilitation and improve the joint range of motion in patients who underwent TKR surgery.

  12. Effects of Liraglutide on Heart Rate and Heart Rate Variability

    DEFF Research Database (Denmark)

    Kumarathurai, Preman; Anholm, Christian; Larsen, Bjørn Strøier

    2017-01-01

    OBJECTIVE: Reduced heart rate variability (HRV) and increased heart rate (HR) have been associated with cardiovascular mortality. Glucagon-like peptide 1 receptor agonists (GLP-1 RAs) increase HR, and studies have suggested that they may reduce HRV. We examined the effect of the GLP-1 RA...

  13. Combined heart-kidney transplantation after total artificial heart insertion.

    Science.gov (United States)

    Ruzza, A; Czer, L S C; Ihnken, K A; Sasevich, M; Trento, A; Ramzy, D; Esmailian, F; Moriguchi, J; Kobashigawa, J; Arabia, F

    2015-01-01

    We present the first single-center report of 2 consecutive cases of combined heart and kidney transplantation after insertion of a total artificial heart (TAH). Both patients had advanced heart failure and developed dialysis-dependent renal failure after implantation of the TAH. The 2 patients underwent successful heart and kidney transplantation, with restoration of normal heart and kidney function. On the basis of this limited experience, we consider TAH a safe and feasible option for bridging carefully selected patients with heart and kidney failure to combined heart and kidney transplantation. Recent FDA approval of the Freedom driver may allow outpatient management at substantial cost savings. The TAH, by virtue of its capability of providing pulsatile flow at 6 to 10 L/min, may be the mechanical circulatory support device most likely to recover patients with marginal renal function and advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Hybrid Continuous-Flow Total Artificial Heart.

    Science.gov (United States)

    Fox, Carson; Chopski, Steven; Murad, Nohra; Allaire, Paul; Mentzer, Robert; Rossano, Joseph; Arabia, Francisco; Throckmorton, Amy

    2018-05-01

    Clinical studies using total artificial hearts (TAHs) have demonstrated that pediatric and adult patients derive quality-of-life benefits from this form of therapy. Two clinically-approved TAHs and other pumps under development, however, have design challenges and limitations, including thromboembolic events, neurologic impairment, infection risk due to large size and percutaneous drivelines, and lack of ambulation, to name a few. To address these limitations, we are developing a hybrid-design, continuous-flow, implantable or extracorporeal, magnetically-levitated TAH for pediatric and adult patients with heart failure. This TAH has only two moving parts: an axial impeller for the pulmonary circulation and a centrifugal impeller for the systemic circulation. This device will utilize the latest generation of magnetic bearing technology. Initial geometries were established using pump design equations, and computational modeling provided insight into pump performance. The designs were the basis for prototype manufacturing and hydraulic testing. The study results demonstrate that the TAH is capable of delivering target blood flow rates of 1-6.5 L/min with pressure rises of 1-92 mm Hg for the pulmonary circulation and 24-150 mm Hg for the systemic circulation at 1500-10 000 rpm. This initial design of the TAH was successful and serves as the foundation to continue its development as a novel, more compact, nonthrombogenic, and effective therapeutic alternative for infants, children, adolescents, and adults with heart failure. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  15. Tachycardia | Fast Heart Rate

    Science.gov (United States)

    ... may recommend or try: Carotid sinus massage: gentle pressure on the neck, where the carotid artery splits into two branches. Must be performed by a healthcare professional to minimize risk of stroke, heart or lung injury from blood clots. Pressing gently on the eyeballs ...

  16. Heart rate variability in newborns.

    Science.gov (United States)

    Javorka, K; Lehotska, Z; Kozar, M; Uhrikova, Z; Kolarovszki, B; Javorka, M; Zibolen, M

    2017-09-22

    Heart rate (HR) and heart rate variability (HRV) in newborns is influenced by genetic determinants, gestational and postnatal age, and other variables. Premature infants have a reduced HRV. In neonatal HRV evaluated by spectral analysis, a dominant activity can be found in low frequency (LF) band (combined parasympathetic and sympathetic component). During the first postnatal days the activity in the high frequency (HF) band (parasympathetic component) rises, together with an increase in LF band and total HRV. Hypotrophy in newborn can cause less mature autonomic cardiac control with a higher contribution of sympathetic activity to HRV as demonstrated by sequence plot analysis. During quiet sleep (QS) in newborns HF oscillations increase - a phenomenon less expressed or missing in premature infants. In active sleep (AS), HRV is enhanced in contrast to reduced activity in HF band due to the rise of spectral activity in LF band. Comparison of the HR and HRV in newborns born by physiological vaginal delivery, without (VD) and with epidural anesthesia (EDA) and via sectio cesarea (SC) showed no significant differences in HR and in HRV time domain parameters. Analysis in the frequency domain revealed, that the lowest sympathetic activity in chronotropic cardiac chronotropic regulation is in the VD group. Different neonatal pathological states can be associated with a reduction of HRV and an improvement in the health conditions is followed by changes in HRV what can be use as a possible prognostic marker. Examination of heart rate variability in neonatology can provide information on the maturity of the cardiac chronotropic regulation in early postnatal life, on postnatal adaptation and in pathological conditions about the potential dysregulation of cardiac function in newborns, especially in preterm infants.

  17. Extracorporeal total artificial heart as bailout surgery.

    Science.gov (United States)

    Perrodin, Stéphanie F; Muller, Olivier; Gronchi, Fabrizio; Liaudet, Lucas; Hullin, Roger; Kirsch, Matthias

    2017-03-01

    We report the use of a total extracorporeal heart for uncontrolled bleeding following a proximal left anterior descending artery perforation, using two centrifugal ventricular assist devices after heart explantation. The literature describing similar techniques and patient outcomes for this "bailout" technique are reviewed. © 2017 Wiley Periodicals, Inc.

  18. Heart rate response to breathing

    DEFF Research Database (Denmark)

    Mehlsen, J; Pagh, K; Nielsen, J S

    1987-01-01

    Heart rate responses to stepwise and periodic changes in lung volume were studied in seven young healthy males. Stepwise inspiration and expiration both resulted in an increase in heart rate followed by a rapid decrease in heart rate. The fastest heart rate was reached in 1.6 +/- 0.5 s and in 3.......6 +/- 1.4 s in response to inspiration and expiration, respectively (P less than 0.01). The slowest heart rate was reached in 4.8 +/- 1.0 s and in 7.6 +/- 1.9 s in response to inspiration and expiration, respectively (P less than 0.01). Following this biphasic change the heart rate returned to a steady...... level. The difference between the fastest and the slowest heart rates was significantly larger in response to inspiration (21.7 +/- 7.3 beats per minute) than in response to expiration (12.0 +/- 7.3 beats per minute; P less than 0.01). Periodic changes in lung volume were performed with frequencies from...

  19. Blood Pressure vs. Heart Rate

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  20. Perioperative Prophylaxis for Total Artificial Heart Transplantation.

    Science.gov (United States)

    Chambers, H E; Pelish, P; Qiu, F; Florescu, D F

    2017-11-01

    Practice variation regarding perioperative antimicrobial prophylaxis in total artificial heart transplantations (TAH-t) across institutions is unknown. The aim of our survey was to assess the current practices for prevention of infection in TAH-t recipients among different programs. An electronic survey was sent to programs that implant Syncardia TAH (Syncardia Systems, Tuscon, Ariz, USA). Proportions were analyzed for categorical variables; means and SDs were analyzed for continuous variables. The majority of centers (80.8%) had a formal surgical infection prophylaxis protocol. For non-penicillin-allergic patients, five (20.1%) institutions reported using a 4-drug regimen, seven (29.2%) used a 3-drug regimen, five (20.1%) used a 2-drug regimen, and seven (29.2%) used a cephalosporin alone. Similar data was seen in the penicillin-allergic patients. Infections were reported to occur postoperatively in 52.2% centers. During the first month after TAH-t, bacteremia represented 27.3%, driveline infections 27.2%, pulmonary infections 9%, and mediastinal infections 18.2%. The most common organisms seen within the first month were Candida spp., Escherichia coli, and Pseudomonas aeruginosa (21.4%). In 65% of centers, the mean rate of death post-TAH-t due to infection was 14.5% (SD, 22.3%). The mean rate of patients surviving until orthotopic heart transplantation was 58.6% (SD, 27.7%). Preventing infections post-TAH-t is key to decreasing morbidity and mortality. All institutions administered perioperative prophylaxis for TAH-t with significant variation among the centers. The majority of the centers have a formal perioperative prophylactic protocol. Copyright © 2017. Published by Elsevier Inc.

  1. Dimensional analysis of heart rate variability in heart transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    Zbilut, J.P.; Mayer-Kress, G.; Geist, K.

    1987-01-01

    We discuss periodicities in the heart rate in normal and transplanted hearts. We then consider the possibility of dimensional analysis of these periodicities in transplanted hearts and problems associated with the record.

  2. Heart rate profile during exercise in patients with early repolarization.

    Science.gov (United States)

    Cay, Serkan; Cagirci, Goksel; Atak, Ramazan; Balbay, Yucel; Demir, Ahmet Duran; Aydogdu, Sinan

    2010-09-01

    Both early repolarization and altered heart rate profile are associated with sudden death. In this study, we aimed to demonstrate an association between early repolarization and heart rate profile during exercise. A total of 84 subjects were included in the study. Comparable 44 subjects with early repolarization and 40 subjects with normal electrocardiogram underwent exercise stress testing. Resting heart rate, maximum heart rate, heart rate increment and decrement were analyzed. Both groups were comparable for baseline characteristics including resting heart rate. Maximum heart rate, heart rate increment and heart rate decrement of the subjects in early repolarization group had significantly decreased maximum heart rate, heart rate increment and heart rate decrement compared to control group (all P decrement (multiple-adjusted OR of the risk of presence of early repolarization was 2.98 (95%CI 1.21-7.34) (P = 0.018) and 7.73 (95%CI 2.84-21.03) (P decrement compared to higher levels, respectively. Subjects with early repolarization have altered heart rate profile during exercise compared to control subjects. This can be related to sudden death.

  3. Liver failure in total artificial heart therapy.

    Science.gov (United States)

    Dimitriou, Alexandros Merkourios; Dapunt, Otto; Knez, Igor; Wasler, Andrae; Oberwalder, Peter; Koerfer, Reiner; Tenderich, Gero; Spiliopoulos, Sotirios

    2016-07-01

    Congestive hepatopathy (CH) and acute liver failure (ALF) are common among biventricular heart failure patients. We sought to evaluate the impact of total artificial heart (TAH) therapy on hepatic function and associated clinical outcomes. A total of 31 patients received a Syncardia Total Artificial Heart. Preoperatively 17 patients exhibited normal liver function or mild hepatic derangements that were clinically insignificant and did not qualify as acute or chronic liver failure, 5 patients exhibited ALF and 9 various hepatic derangements owing to CH. Liver associated mortality and postoperative course of liver values were prospectively documented and retrospectively analyzed. Liver associated mortality in normal liver function, ALF and CH cases was 0%, 20% (P=0.03) and 44.4% (P=0.0008) respectively. 1/17 (5.8%) patients with a normal liver function developed an ALF, 4/5 (80%) patients with an ALF experienced a markedly improvement of hepatic function and 6/9 (66.6%) patients with CH a significant deterioration. TAH therapy results in recovery of hepatic function in ALF cases. Patients with CH prior to surgery form a high risk group with increased liver associated mortality.

  4. Monitoring nocturnal heart rate with bed sensor.

    Science.gov (United States)

    Migliorini, M; Kortelainen, J M; Pärkkä, J; Tenhunen, M; Himanen, S L; Bianchi, A M

    2014-01-01

    This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG). Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection. On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected. The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.

  5. Collagen synthesis in CBA mouse heart after total thoracic irradiation

    International Nuclear Information System (INIS)

    Murray, J.C.; Parkins, C.S.; Institute of Cancer Research, Sutton

    1988-01-01

    CBA mice were irradiated to the whole thorax with single doses of 240 kVp X-rays in the dose range 8-16 Gy. Collagen and total protein synthesis rates in the heart were measured at 2-monthly intervals using a radio-isotope incorporation techniques. Doses of 10 Gy or greater caused a slight increase in collagen synthesis, followed by significantly reduced collagen synthesis by 16 weeks or longer after treatment. The depression in synthesis appeared correspondingly earlier with increasing dose. Total protein synthesis in heart followed similar patterns although changes were not statistically significant, indicating that the changes reflected alterations to collagen synthesis specifally, and not protein synthesis in geneal. Total hydroxyproline measurements showed no significant changes in heart collagen at any time as a result of X-irradiation. 18 refs.; 7 figs

  6. Reduced Dietary Sodium Intake Increases Heart Rate

    DEFF Research Database (Denmark)

    Graudal, Niels A; Hubeck-Graudal, Thorbjørn; Jürgens, Gesche

    2016-01-01

    Reduced dietary sodium intake (sodium reduction) increases heart rate in some studies of animals and humans. As heart rate is independently associated with the development of heart failure and increased risk of premature death a potential increase in heart rate could be a harmful side......-effect of sodium reduction. The purpose of the present meta-analysis was to investigate the effect of sodium reduction on heart rate. Relevant studies were retrieved from an updated pool of 176 randomized controlled trials (RCTs) published in the period 1973-2014. Sixty-three of the RCTs including 72 study...... populations reported data on heart rate. In a meta-analysis of these data sodium reduction increased heart rate with 1.65 beats per minute [95% CI: 1.19, 2.11], p heart rate. This effect was independent of baseline blood pressure. In conclusion sodium reduction...

  7. Successful heart transplantation in patients with total artificial heart infections.

    Science.gov (United States)

    Taimur, Sarah; Sullivan, Timothy; Rana, Mennakshi; Patel, Gopi; Roldan, Julie; Ashley, Kimberly; Pinney, Sean; Anyanwu, Anelechi; Huprikar, Shirish

    2018-02-01

    Data are limited on clinical outcomes in patients awaiting heart transplant (HT) with total artificial heart (TAH) infections. We retrospectively reviewed all TAH recipients at our center. TAH infection was classified as definite if a microorganism was isolated in cultures from the exit site or deep tissues around the TAH; as probable in patients without surgical or microbiologic evidence of infection but no other explanation for persistent or recurrent bloodstream infection (BSI); or possible in patients with clinical suspicion and radiographic findings suggestive of TAH infection, but without surgical intervention or microbiologic evidence. From 2012 to 2015, a total of 13 patients received a TAH, with a median age at implantation of 52 years (range: 28-60). TAH infection occurred in nine patients (seven definite, one probable, one possible) a median of 41 days after implant (range: 17-475). The majority of TAH infections were caused by Staphylococcus species. Seven of nine patients underwent HT (four had pre-HT mediastinal washout, and five had positive HT operative cultures). Three patients had an active BSI caused by the same pathogen causing TAH infection at the time of HT, with one developing a post-HT BSI with the same bacteria. No patient developed post-HT surgical site infection caused by the TAH infection pathogen. No deaths among HT recipients were attributed to infection. TAH infection is frequently associated with BSI and mediastinitis and Staphylococcus was the most common pathogen. A multimodal approach of appropriate pre- and post-HT antimicrobial therapy, surgical drainage, and heart transplantation with radical mediastinal debridement was successful in curing infection. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Future Prospects for the Total Artificial Heart.

    Science.gov (United States)

    Sunagawa, Gengo; Horvath, David J; Karimov, Jamshid H; Moazami, Nader; Fukamachi, Kiyotaka

    2016-01-01

    A total artificial heart (TAH) is the sole remaining option for patients with biventricular failure who cannot be rescued by left ventricular assist devices (LVADs) alone. However, the pulsatile TAH in clinical use today has limitations: large pump size, unknown durability, required complex anticoagulation regimen, and association with significant postsurgical complications. That pump is noisy; its large pneumatic driving lines traverse the body, with bulky external components for its drivers. Continuous-flow pumps, which caused a paradigm shift in the LVAD field, have already contributed to the rapidly evolving development of TAHs. Novel continuous-flow TAHs are only in preclinical testing or developmental stages. We here review the current state of TAHs, with recommended requirements for the TAH of the future.

  9. The Total Artificial Heart in End-Stage Congenital Heart Disease.

    Science.gov (United States)

    Villa, Chet R; Morales, David L S

    2017-01-01

    The development of durable ventricular assist devices (VADs) has improved mortality rates and quality of life in patients with end stage heart failure. While the use of VADs has increased dramatically in recent years, there is limited experience with VAD implantation in patients with complex congenital heart disease (CHD), despite the fact that the number of patients with end stage CHD has grown due to improvements in surgical and medical care. VAD use has been limited in patients with CHD and end stage heart failure due to anatomic (systemic right ventricle, single ventricle, surgically altered anatomy, valve dysfunction, etc.) and physiologic constraints (diastolic dysfunction). The total artificial heart (TAH), which has right and left sided pumps that can be arranged in a variety of orientations, can accommodate the anatomic variation present in CHD patients. This review provides an overview of the potential use of the TAH in patients with CHD.

  10. Bluetooth Heart Rate Monitors For Spaceflight

    Science.gov (United States)

    Buxton, R. E.; West, M. R.; Kalogera, K. L.; Hanson, A. M.

    2016-01-01

    Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be

  11. Heart rate variability and swimming.

    Science.gov (United States)

    Koenig, Julian; Jarczok, Marc N; Wasner, Mieke; Hillecke, Thomas K; Thayer, Julian F

    2014-10-01

    Professionals in the domain of swimming have a strong interest in implementing research methods in evaluating and improving training methods to maximize athletic performance and competitive outcome. Heart rate variability (HRV) has gained attention in research on sport and exercise to assess autonomic nervous system activity underlying physical activity and sports performance. Studies on swimming and HRV are rare. This review aims to summarize the current evidence on the application of HRV in swimming research and draws implications for future research. A systematic search of databases (PubMed via MEDLINE, PSYNDEX and Embase) according to the PRISMA statement was employed. Studies were screened for eligibility on inclusion criteria: (a) empirical investigation (HRV) in humans (non-clinical); (b) related to swimming; (c) peer-reviewed journal; and (d) English language. The search revealed 194 studies (duplicates removed), of which the abstract was screened for eligibility. Fourteen studies meeting the inclusion criteria were included in the review. Included studies broadly fell into three classes: (1) control group designs to investigate between-subject differences (i.e. swimmers vs. non-swimmers, swimmers vs. other athletes); (2) repeated measures designs on within-subject differences of interventional studies measuring HRV to address different modalities of training or recovery; and (3) other studies, on the agreement of HRV with other measures. The feasibility and possibilities of HRV within this particular field of application are well documented within the existing literature. Future studies, focusing on translational approaches that transfer current evidence in general practice (i.e. training of athletes) are needed.

  12. Mental load, heart rate and heart rate variability.

    NARCIS (Netherlands)

    Blitz, P.S.; Hoogstraten, J.; Mulder, G.

    1970-01-01

    "Several investigators have shown that diminished sinus arrhythmia can be seen as an indication of increased mental load. The present experiment deals with the influence of different levels of mental load, operationalized as the number of binary choices per minute, on the regularity of the heart

  13. Measuring heart rate with optical sensor

    NARCIS (Netherlands)

    Barachi, M. (Mitra)

    2014-01-01

    The problem addressed in this report is to verify the possibility of using an optical sensor in the SaxShirt in order to extract the heart rate. There are specifically three questions that we try to address. 1) How is it possible to extract heart rate (BPM) from the optical sensor? 2) Is it

  14. Peak heart rates at extreme altitudes

    DEFF Research Database (Denmark)

    Lundby, C; Van Hall, Gerrit

    2001-01-01

    We have measured maximal heart rate during a graded maximal bicycle exercise test to exhaustion in five healthy climbers before and during an expedition to Mt. Everest. Maximal heart rates at sea level were 186 (177-204) beats/min(-1) at sea level and 170 (169-182) beats/min(-1) with acute hypoxi...

  15. [Resonance hypothesis of heart rate variability origin].

    Science.gov (United States)

    Sheĭkh-Zade, Iu R; Mukhambetaliev, G Kh; Cherednik, I L

    2009-09-01

    A hypothesis is advanced of the heart rate variability being subjected to beat-to-beat regulation of cardiac cycle duration in order to ensure the resonance interaction between respiratory and own fluctuation of the arterial system volume for minimization of power expenses of cardiorespiratory system. Myogenic, parasympathetic and sympathetic machanisms of heart rate variability are described.

  16. Intrapartum fetal heart rate profiles with and without fetal asphyxia.

    Science.gov (United States)

    Low, J A; Pancham, S R; Worthington, D N

    1977-04-01

    Fetal heart rate profiles for periods up to 12 hours prior to delivery have been reviewed in 515 patients with a fetus at risk. Mechanisms other than fetal asphyxia will cause fetal heart rate decelerations, and fetal asphyxia may in some instances develop in the absence of total or late decelerations. However, an increasing incidence of total decelerations and late decelerations and particularly a marked pattern of total decelerations and late decelerations are of value in the prediction of fetal asphyxia. Fetal heart rate deceleration patterns can predict the probability of fetal asphyxia at the time of initial intervention, while a progression of fetal heart rate deceleration patterns in the individual fetus can be of assistance in the subsequent scheduling of serial acid-base assessments during labor.

  17. Total excitation of the isolated human heart

    NARCIS (Netherlands)

    Durrer, D.; Dam, R.Th. van; Freud, G.E.; Janse, M.J.; Meijler, F.L.; Arzbaecher, R.C.

    To obtain information conceming the time course and instantaneous distribution of the excitatory process of the normal human healt, studies were made on isolated human hearts from seven individuals who died from various cerebral conditions, but who had no history of cardiac disease. Measurements

  18. Heart rate variability in healthy population

    International Nuclear Information System (INIS)

    Alamgir, M.; Hussain, M.M.

    2010-01-01

    Background: Heart rate variability has been considered as an indicator of autonomic status. Little work has been done on heart rate variability in normal healthy volunteers. We aimed at evolving the reference values of heart rate variability in our healthy population. Methods: Twenty-four hour holter monitoring of 37 healthy individuals was done using Holter ECG recorder 'Life card CF' from 'Reynolds Medical'. Heart rate variability in both time and frequency domains was analysed with 'Reynolds Medical Pathfinder Digital/700'. Results: The heart rate variability in normal healthy volunteers of our population was found in time domain using standard deviation of R-R intervals (SDNN), standard deviation of average NN intervals (SDANN), and Square root of the mean squared differences of successive NN intervals (RMSSD). Variation in heart rate variability indices was observed between local and foreign volunteers and RMSSD was found significantly increased (p<0.05) in local population. Conclusions: The values of heart rate variability (RMSSD) in healthy Pakistani volunteers were found increased compared to the foreign data reflecting parasympathetic dominance in our population. (author)

  19. Metaiodobenzylguanidine and heart rate variability in heart failure

    International Nuclear Information System (INIS)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-01-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac 123 I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  20. Metaiodobenzylguanidine and heart rate variability in heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-10-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  1. Renal Function Recovery with Total Artificial Heart Support.

    Science.gov (United States)

    Quader, Mohammed A; Goodreau, Adam M; Shah, Keyur B; Katlaps, Gundars; Cooke, Richard; Smallfield, Melissa C; Tchoukina, Inna F; Wolfe, Luke G; Kasirajan, Vigneshwar

    2016-01-01

    Heart failure patients requiring total artificial heart (TAH) support often have concomitant renal insufficiency (RI). We sought to quantify renal function recovery in patients supported with TAH at our institution. Renal function data at 30, 90, and 180 days after TAH implantation were analyzed for patients with RI, defined as hemodialysis supported or an estimated glomerular filtration rate (eGFR) less than 60 ml/min/1.73 m. Between January 2008 and December 2013, 20 of the 46 (43.5%) TAH recipients (age 51 ± 9 years, 85% men) had RI, mean preoperative eGFR of 48 ± 7 ml/min/1.73 m. Renal function recovery was noted at each follow-up interval: increment in eGFR (ml/min/1.73 m) at 30, 90, and 180 days was 21 ± 35 (p = 0.1), 16.5 ± 18 (p = 0.05), and 10 ± 9 (p = 0.1), respectively. Six patients (30%) required preoperative dialysis. Of these, four recovered renal function, one remained on dialysis, and one died. Six patients (30%) required new-onset dialysis. Of these, three recovered renal function and three died. Overall, 75% (15 of 20) of patients' renal function improved with TAH support. Total artificial heart support improved renal function in 75% of patients with pre-existing significant RI, including those who required preoperative dialysis.

  2. [Review of wireless energy transmission system for total artificial heart].

    Science.gov (United States)

    Zhang, Chi; Yang, Ming

    2009-11-01

    This paper sums up the fundamental structure of wireless energy transmission system for total artificial heart, and compares the key parameters and performance of some representative systems. After that, it is discussed that the future development trend of wireless energy transmission system for total artificial heart.

  3. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  4. Fetal Heart Rate Monitoring during Labor

    Science.gov (United States)

    ... What are the types of monitoring? • How is auscultation performed? • How is electronic fetal monitoring performed? • How ... methods of fetal heart rate monitoring in labor. Auscultation is a method of periodically listening to the ...

  5. The relationship between phase and heart rate

    International Nuclear Information System (INIS)

    Underwood, S.R.; Walton, S.; Brown, N.J.G.; Laming, P.J.; Ell, P.J.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    The Fourier phase image is used in rest and stress radionuclide angiocardiography to assess the timing of ventricular wall motion in a regional fashion, and areas of high phase are taken to reprensent areas of delayed contraction. However, phase increases with heart rate and this can make interpretation difficult. This study investigates the relationship between phase and heart rate. A heterogenous group of 43 subjects was studied by ECG-gated equilibrium radionuclide angiocardiography, all of the subjects having normal extent of left ventricular wall motion as judged by normal ejection fraction and normal amplitude image. Mean left ventricular phase correlated well with mean time of end systole (r=0.92), but there was no correlation with time of end diastole.Thus phase reflects the time of end systole as a proportion of cycle length and should be linearly related to heart rate provided the duration of systole is unchanged. In 28 normal subjects mean left ventricular phase correlated linearly with resting rate (r=0.91), and when exercised the relationship was maintained up to 90 beats per minute. Above this rate the increases were less marked as the duration of systole shortened. The same was true in 4 subjects paced at different rates. Mean resting heart rate in the normal subjects was 70 beats per minute and correcting phase linearly to rate 70 did not change mean left ventricular phase but did decrease the standard deviation from 18 degree to 12 degree. It is concluded that correcting phase for heart rate below 90 beats per minute will increase the sensitivity of the phase image to abnormalities of the timing of ventricular contraction. This correction should be appropriate in resting, isometric exercise, and cold pressor studies but because of the higher heart rates involved will not be appropriate for bicycle exercise. (Author)

  6. Current state of total artificial heart therapy and introduction of the most important total artificial heart systems.

    Science.gov (United States)

    Spiliopoulos, Sotirios; Hergesell, Vera; Wasler, Andrae; Dapunt, Otto

    2018-06-14

    Due to the declining instances of organ donation, total artificial heart (TAH) therapy is of increasing importance for the management of end-stage biventricular heart failure. We introduce the currently most important established and novel TAH systems (SynCardia, CARMAT, ReinHeart, BiVACOR), report clinical outcomes and discuss technical requirements for the successful implementation of TAH therapy as an alternative to cardiac transplantation.

  7. Perioperative Care of the Patient With the Total Artificial Heart.

    Science.gov (United States)

    Yaung, Jill; Arabia, Francisco A; Nurok, Michael

    2017-05-01

    Advanced heart failure continues to be a leading cause of morbidity and mortality despite improvements in pharmacologic therapy. High demand for cardiac transplantation and shortage of donor organs have led to an increase in the utilization of mechanical circulatory support devices. The total artificial heart is an effective biventricular assist device that may be used as a bridge to transplant and that is being studied for destination therapy. This review discusses the history, indications, and perioperative management of the total artificial heart with emphasis on the postoperative concerns.

  8. Heart Rate Variability - A Historical Perspective

    Directory of Open Access Journals (Sweden)

    George E Billman

    2011-11-01

    Full Text Available Heart rate variability (HRV, the beat-to-beat variation in either heart rate or the duration of the R-R interval – the heart period, has become a popular clinical and investigational tool. The temporal fluctuations in heart rate exhibit a marked synchrony with respiration (increasing during inspiration and decreasing during expiration – the so called respiratory sinus arrhythmia, RSA and are widely believed to reflect changes in cardiac autonomic regulation. Although the exact contributions of the parasympathetic and the sympathetic divisions of the autonomic nervous system to this variability are controversial and remain the subject of active investigation and debate, a number of time and frequency domain techniques have been developed to provide insight into cardiac autonomic regulation in both health and disease. It is the purpose of this essay to provide an historical overview of the evolution in the concept of heart rate variability. Briefly, pulse rate was first measured by ancient Greek physicians and scientists. However, it was not until the invention of the Physician’s Pulse Watch (a watch with a second hand that could be stopped in 1707 that changes in pulse rate could be accurately assessed. The Rev. Stephen Hales (1733 was the first to note that pulse varied with respiration and in 1847 Carl Ludwig was the first to record RSA. With the measurement of the ECG (1895 and advent of digital signal processing techniques in the 1960’s, investigation of HRV and its relationship to health and disease has exploded. This essay will conclude with a brief description of time domain, frequency domain, and non-linear dynamic analysis techniques (and their limitations that are commonly used to measure heart rate variability.

  9. Heart rate response to hypoxic exercise

    DEFF Research Database (Denmark)

    Lundby, C; Møller, P; Kanstrup, I L

    2001-01-01

    progressively decreased the maximal heart rate from day 1 and onwards; also, hypoxia by itself increased plasma noradrenaline levels after maximal exercise. Domperidone further increased maximal noradrenaline concentrations, but had no effect on maximal heart rate. On each study day at altitude, oxygen......This study examined the effects of dopamine D(2)-receptor blockade on the early decrease in maximal heart rate at high altitude (4559 m). We also attempted to clarify the time-dependent component of this reduction and the extent to which it is reversed by oxygen breathing. Twelve subjects performed...... two consecutive maximal exercise tests, without and with oxygen supplementation respectively, at sea level and after 1, 3 and 5 days at altitude. On each study day, domperidone (30 mg; n=6) or no medication (n=6) was given 1 h before the first exercise session. Compared with sea level, hypoxia...

  10. Monitoring apparatus for monitoring a user's heart rate and/or heart rate variation

    NARCIS (Netherlands)

    2012-01-01

    A monitoring apparatus (4) monitors a user's heart rate and/or heart rate variation. The apparatus includes a capacitor (22) which is positionable on or near a body part of a person, for example a person's limb, for example an arm (3), such that an electrical capacitance of the capacitor (22) is

  11. Effects of social stress on heart rate and heart rate variability in growing pigs

    NARCIS (Netherlands)

    Jong, de I.C.; Sgoifo, A.; Lambooij, E.; Korte, S.M.; Blokhuis, H.J.; Koolhaas, J.M.

    2000-01-01

    The effects of social stress on heart rate, heart rate variability and the occurrence of cardiac arrhythmias were studied in 12 growing pigs. Social stress was induced during a good competition test with a pen mate, and subsequently during a resident-intruder test with an unacquainted pig in which

  12. Effects of social stress on heart rate and heart rate variability in growing pigs

    NARCIS (Netherlands)

    de Jong, IC; Sgoifo, A; Lambooij, E; Korte, SM; Blokhuis, HJ; Koolhaas, JM

    The effects of social stress on heart rate, heart rate variability and the occurrence of cardiac arrhythmias were studied in 12 growing pigs. Social stress was induced during a good competition test with a pen mate, and subsequently during a resident-intruder test with an unacquainted pig in which

  13. Heart rate variability in bipolar disorder

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria; Kessing, Lars Vedel; Munkholm, Klaus

    2017-01-01

    Background Heart rate variability (HRV) has been suggested reduced in bipolar disorder (BD) compared with healthy individuals (HC). This meta-analysis investigated: HRV differences in BD compared with HC, major depressive disorder or schizophrenia; HRV differences between affective states; HRV...

  14. Heart Rate and Increased Intravascular Volume

    Czech Academy of Sciences Publication Activity Database

    Souček, M.; Kára, T.; Jurák, Pavel; Halámek, Josef; Špinarová, L.; Meluzín, J.; Toman, J.; Řiháček, I.; Šumbera, J.; Fráňa, P.

    2003-01-01

    Roč. 52, - (2003), s. 137 - 140 ISSN 0862-8408 R&D Projects: GA ČR GA102/02/1339 Institutional research plan: CEZ:AV0Z2065902 Keywords : kidneys * heart rate * atrial mechanisms Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 0.939, year: 2003

  15. Heart Rate Fragmentation: A Symbolic Dynamical Approach

    Directory of Open Access Journals (Sweden)

    Madalena D. Costa

    2017-11-01

    Full Text Available Background: We recently introduced the concept of heart rate fragmentation along with a set of metrics for its quantification. The term was coined to refer to an increase in the percentage of changes in heart rate acceleration sign, a dynamical marker of a type of anomalous variability. The effort was motivated by the observation that fragmentation, which is consistent with the breakdown of the neuroautonomic-electrophysiologic control system of the sino-atrial node, could confound traditional short-term analysis of heart rate variability.Objective: The objectives of this study were to: (1 introduce a symbolic dynamical approach to the problem of quantifying heart rate fragmentation; (2 evaluate how the distribution of the different dynamical patterns (“words” varied with the participants' age in a group of healthy subjects and patients with coronary artery disease (CAD; and (3 quantify the differences in the fragmentation patterns between the two sample populations.Methods: The symbolic dynamical method employed here was based on a ternary map of the increment NN interval time series and on the analysis of the relative frequency of symbolic sequences (words with a pre-defined set of features. We analyzed annotated, open-access Holter databases of healthy subjects and patients with CAD, provided by the University of Rochester Telemetric and Holter ECG Warehouse (THEW.Results: The degree of fragmentation was significantly higher in older individuals than in their younger counterparts. However, the fragmentation patterns were different in the two sample populations. In healthy subjects, older age was significantly associated with a higher percentage of transitions from acceleration/deceleration to zero acceleration and vice versa (termed “soft” inflection points. In patients with CAD, older age was also significantly associated with higher percentages of frank reversals in heart rate acceleration (transitions from acceleration to

  16. Depression and heart rate variability in firefighters

    Directory of Open Access Journals (Sweden)

    Li-Mei Liao

    2014-07-01

    Full Text Available Introduction: Depression has been found to increase the risk of mortality in patients with coronary artery disease through a mechanism of changing cardiac autonomic tone which is reflected by alteration of heart rate variability indices. This study investigated whether such mechanism existed in firefighters who were at high risk of depression and sudden cardiac death. Methods and results: In total, 107 firefighters were recruited. All completed Beck Depression Inventory and underwent 24-h ambulatory electrocardiographic monitoring. The root-mean-square of successive differences, standard deviation of all normal-to-normal intervals index, and the percentage of differences between adjacent normal-to-normal intervals >50 ms were significantly lower in depressed than in non-depressed firefighters after controlling for hypertension, age, and body mass index (40.1 ± 18.8 vs 62.5 ± 77.4, p < 0.01; 63.0 ± 19.2 vs 72.1 ± 34.8, p < 0.01; 8.4 ± 7.2 vs 12.7 ± 10.9, p < 0.01, respectively. Conclusion: Decreased vagal tone is a possible mechanism linking depression and sudden cardiac death in firefighters.

  17. Ethical Analysis of Withdrawing Total Artificial Heart Support.

    Science.gov (United States)

    DeMartino, Erin S; Wordingham, Sara E; Stulak, John M; Boilson, Barry A; Fuechtmann, Kayla R; Singh, Nausheen; Sulmasy, Daniel P; Pajaro, Octavio E; Mueller, Paul S

    2017-05-01

    To describe the characteristics of patients who undergo withdrawal of total artificial heart support and to explore the ethical aspects of withdrawing this life-sustaining treatment. We retrospectively reviewed the medical records of all adult recipients of a total artificial heart at Mayo Clinic from the program's inception in 2007 through June 30, 2015. Management of other life-sustaining therapies, approach to end-of-life decision making, engagement of ethics and palliative care consultation, and causes of death were analyzed. Of 47 total artificial heart recipients, 14 patients or their surrogates (30%) requested withdrawal of total artificial heart support. No request was denied by treatment teams. All 14 patients were supported with at least 1 other life-sustaining therapy. Only 1 patient was able to participate in decision making. It is widely held to be ethically permissible to withdraw a life-sustaining treatment when the treatment no longer meets the patient's health care-related goals (ie, the burdens outweigh the benefits). These data suggest that some patients, surrogates, physicians, and other care providers believe that this principle extends to the withdrawal of total artificial heart support. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  18. Early Embryonic Heart Rate in Normal Pregnancies In Memory of ...

    African Journals Online (AJOL)

    To determine the appearance and development of embryonic heart rate a total of n = 317 Nigerian pregnant women were studied in the very early pregnancy from 23 – 56 days from the onset of last menstrual period (LMP). All pregnancies had a subsequent successful outcome. Transvaginal ultrasonography was ...

  19. Gaussian Mixture Model of Heart Rate Variability

    Science.gov (United States)

    Costa, Tommaso; Boccignone, Giuseppe; Ferraro, Mario

    2012-01-01

    Heart rate variability (HRV) is an important measure of sympathetic and parasympathetic functions of the autonomic nervous system and a key indicator of cardiovascular condition. This paper proposes a novel method to investigate HRV, namely by modelling it as a linear combination of Gaussians. Results show that three Gaussians are enough to describe the stationary statistics of heart variability and to provide a straightforward interpretation of the HRV power spectrum. Comparisons have been made also with synthetic data generated from different physiologically based models showing the plausibility of the Gaussian mixture parameters. PMID:22666386

  20. Rapid Speed Modulation of a Rotary Total Artificial Heart Impeller.

    Science.gov (United States)

    Kleinheyer, Matthias; Timms, Daniel L; Tansley, Geoffrey D; Nestler, Frank; Greatrex, Nicholas A; Frazier, O Howard; Cohn, William E

    2016-09-01

    Unlike the earlier reciprocating volume displacement-type pumps, rotary blood pumps (RBPs) typically operate at a constant rotational speed and produce continuous outflow. When RBP technology is used in constructing a total artificial heart (TAH), the pressure waveform that the TAH produces is flat, without the rise and fall associated with a normal arterial pulse. Several studies have suggested that pulseless circulation may impair microcirculatory perfusion and the autoregulatory response and may contribute to adverse events such as gastrointestinal bleeding, arteriovenous malformations, and pump thrombosis. It may therefore be beneficial to attempt to reproduce pulsatile output, similar to that generated by the native heart, by rapidly modulating the speed of an RBP impeller. The choice of an appropriate speed profile and control strategy to generate physiologic waveforms while minimizing power consumption and blood trauma becomes a challenge. In this study, pump operation modes with six different speed profiles using the BiVACOR TAH were evaluated in vitro. These modes were compared with respect to: hemodynamic pulsatility, which was quantified as surplus hemodynamic energy (SHE); maximum rate of change of pressure (dP/dt); pulse power index; and motor power consumption as a function of pulse pressure. The results showed that the evaluated variables underwent different trends in response to changes in the speed profile shape. The findings indicated a possible trade-off between SHE levels and flow rate pulsatility related to the relative systolic duration in the speed profile. Furthermore, none of the evaluated measures was sufficient to fully characterize hemodynamic pulsatility. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  1. Total artificial heart implantation in a young Marfan syndrome patient.

    Science.gov (United States)

    Rao, Prashant; Keenan, Jack B; Rajab, Taufiek K; Kim, Samuel; Smith, Richard; Amabile, Orazio; Khalpey, Zain

    2018-03-01

    Cardiovascular complications represent the leading cause of morbidity and mortality in patients with Marfan syndrome. Here, we describe a unique case where a total artificial heart was implanted in a young Marfan syndrome woman. A 22-year-old postpartum African American female with Marfan syndrome developed multiple severe valve dysfunction and biventricular failure that was refractory to medical management. She previously had a Bentall procedure for Type A aortic dissection and repair of a Type B dissection. We implanted a total artificial heart with a good outcome. Total artificial heart is a durable option for severe biventricular failure and multiple valvular dysfunction as a bridge to transplant in a young patient with Marfan syndrome.

  2. Percutaneous dilatational tracheostomy following total artificial heart implantation.

    Science.gov (United States)

    Spiliopoulos, Sotirios; Dimitriou, Alexandros Merkourios; Serrano, Maria Rosario; Guersoy, Dilek; Autschbach, Ruediger; Goetzenich, Andreas; Koerfer, Reiner; Tenderich, Gero

    2015-07-01

    Coagulation disorders and an immune-altered state are common among total artificial heart patients. In this context, we sought to evaluate the safety of percutaneous dilatational tracheostomy in cases of prolonged need for mechanical ventilatory support. We retrospectively analysed the charts of 11 total artificial heart patients who received percutaneous dilatational tracheostomy. We focused on early and late complications. We observed no major complications and no procedure-related deaths. Early minor complications included venous oozing (45.4%) and one case of local infection. Late complications, including subglottic stenosis, stomal infection or infections of the lower respiratory tract, were not observed. In conclusion, percutaneous dilatational tracheostomy in total artificial heart patients is safe. Considering the well-known benefits of early tracheotomy over prolonged translaryngeal intubation, we advocate early timing of therapy in cases of prolonged mechanical ventilation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  3. The Effect of Heart Rate on the Heart Rate Variability Response to Autonomic Interventions

    Directory of Open Access Journals (Sweden)

    George E Billman

    2013-08-01

    Full Text Available Heart rate variability (HRV, the beat-to-beat variation in either heart rate (HR or heart period (R-R interval, has become a popular clinical and investigational tool to quantify cardiac autonomic regulation. However, it is not widely appreciated that, due to the inverse curvilinear relationship between HR and R-R interval, HR per se can profoundly influence HRV. It is, therefore, critical to correct HRV for the prevailing HR particularly, as HR changes in response to autonomic neural activation or inhibition. The present study evaluated the effects of HR on the HRV response to autonomic interventions that either increased (submaximal exercise, n = 25 or baroreceptor reflex activation, n = 20 or reduced (pharmacological blockade: β-adrenergic receptor, muscarinic receptor antagonists alone and in combination, n = 25, or bilateral cervical vagotomy, n = 9 autonomic neural activity in a canine model. Both total (RR interval standard deviation, RRSD and the high frequency variability (HF, 0.2 to 1.04 Hz were determined before and in response to an autonomic intervention. All interventions that reduced or abolished cardiac parasympathetic regulation provoked large reductions in HRV even after HR correction [division by mean RRsec or (mean RRsec2 for RRSD and HF, respectively] while interventions that reduced HR yielded mixed results. β-adrenergic receptor blockade reduced HRV (RRSD but not HF while both RRSD and HF increased in response to increases in arterial blood (baroreceptor reflex activation even after HR correction. These data suggest that the physiological basis for HRV is revealed after correction for prevailing HR and, further, that cardiac parasympathetic activity is responsible for a major portion of the HRV in the dog.

  4. Multigated radionuclide study of the total artificial heart

    Energy Technology Data Exchange (ETDEWEB)

    Datz, F L; Christian, P E; Taylor, A Jr; Hastings, W L; De Vries, W C

    1987-07-01

    A permanent total artificial heart, the Jarvik-7, was implanted into a 61-year-old male with a severe cardiomyopathy. Gated radionuclide studies were performed in the patient both prior to surgery and following implantation. Preoperative gated radionuclide cardiac studies revealed marked left ventricular enlargement, severe hypokinesis and a left ventricular ejection fraction of 10%. The right ventricle was moderately enlarged with a 27% ejection fraction. Following implantation of the Jarvik-7 artificial heart, gated cardiac studies were performed with a computer gated by a signal from the heart controller. The left ventricular ejection fraction was 69% and the right ventricular ejection fraction was 62%. This compared to a theoretical ejection fraction of 74% for each ventricle based on chamber anatomy. There was excellent ventricular emptying. Phase analysis showed uniform diaphragm motion. The use of gated cardiac studies in humans may prove helpful in evaluating mechanical problems with the artificial heart, such as manlfunction of the diaphragm, before they become clinically apparent.

  5. AUTONOMIC CONTROL OF HEART RATE AFTER EXERCISE IN TRAINED WRESTLERS

    Directory of Open Access Journals (Sweden)

    Carlos F Henríquez

    2013-04-01

    Full Text Available The objective of this study was to establish differences in vagal reactivation, through heart rate recovery and heart rate variability post exercise, in Brazilian jiu-jitsu wrestlers (BJJW. A total of 18 male athletes were evaluated, ten highly trained (HT and eight moderately trained (MT, who performed a maximum incremental test. At the end of the exercise, the R-R intervals were recorded during the first minute of recovery. We calculated heart rate recovery (HRR60s, and performed linear and non-linear (standard deviation of instantaneous beat-to-beat R-R interval variability – SD1 analysis of heart rate variability (HRV, using the tachogram of the first minute of recovery divided into four segments of 15 s each (0-15 s, 15-30 s, 30-45 s, 45-60 s. Between HT and MT individuals, there were statistically significant differences in HRR60s (p <0.05 and in the non linear analysis of HRV from SD130-45s (p <0.05 and SD145-60s (p <0.05. The results of this research suggest that heart rate kinetics during the first minute after exercise are related to training level and can be used as an index for autonomic cardiovascular control in BJJW.

  6. Heart rate variability - a historical perspective.

    Science.gov (United States)

    Billman, George E

    2011-01-01

    Heart rate variability (HRV), the beat-to-beat variation in either heart rate or the duration of the R-R interval - the heart period, has become a popular clinical and investigational tool. The temporal fluctuations in heart rate exhibit a marked synchrony with respiration (increasing during inspiration and decreasing during expiration - the so called respiratory sinus arrhythmia, RSA) and are widely believed to reflect changes in cardiac autonomic regulation. Although the exact contributions of the parasympathetic and the sympathetic divisions of the autonomic nervous system to this variability are controversial and remain the subject of active investigation and debate, a number of time and frequency domain techniques have been developed to provide insight into cardiac autonomic regulation in both health and disease. It is the purpose of this essay to provide an historical overview of the evolution in the concept of HRV. Briefly, pulse rate was first measured by ancient Greek physicians and scientists. However, it was not until the invention of the "Physician's Pulse Watch" (a watch with a second hand that could be stopped) in 1707 that changes in pulse rate could be accurately assessed. The Rev. Stephen Hales (1733) was the first to note that pulse varied with respiration and in 1847 Carl Ludwig was the first to record RSA. With the measurement of the ECG (1895) and advent of digital signal processing techniques in the 1960s, investigation of HRV and its relationship to health and disease has exploded. This essay will conclude with a brief description of time domain, frequency domain, and non-linear dynamic analysis techniques (and their limitations) that are commonly used to measure HRV.

  7. Total Artificial Heart Implantation as a Bridge to Heart Transplantation in an Active Duty Service Member With Amyloid Cardiomyopathy.

    Science.gov (United States)

    Scully, Michael S; Wessman, Dylan E; McKee, James M; Francisco, Gregory M; Nayak, Keshav R; Kobashigawa, Jon A

    2017-03-01

    Cardiac involvement by light-chain (AL) amyloid occurs in up to 50% of patients with primary AL amyloidosis. The prognosis of amyloid heart disease is poor with 1-year survival rates of 35 to 40%. Historically, heart transplantation was considered controversial for patients with AL amyloid cardiomyopathy (CM) given the systemic nature of the disease and poor survival. We present a case report of an active duty service member diagnosed with advanced cardiac amyloid who underwent total artificial heart transplant as a bridge to heart transplant and eventual autologous stem cell transplant. A 47-year-old active duty male initially evaluated for atypical chest pain was found to have severe concentric left ventricular hypertrophy on echocardiogram but normal voltage on electrocardiogram. Cardiac magnetic resonance imaging, laboratory studies, and bone marrow biopsy established the diagnosis of cardiac amyloidosis. At the time of diagnosis, the patient's prognosis was very poor with a median survival of 5 months on the basis of the Mayo Clinic revised prognostic staging system for amyloidosis. The patient developed rapidly progressive left ventricular dysfunction and heart failure leading to cardiac arrest. The patient received a total artificial heart as a bridge to orthotopic heart and kidney transplantation and eventual stem cell transplant. He continues to be in remission and has a fair functional capacity without restriction in activities of daily living or moderate exercise. Amyloid CM is a rare and devastating disease. The natural course of the disease has made heart transplant in these patients controversial. Modern advancements in chemotherapies and advanced heart failure treatments have improved outcomes for select patients with AL amyloid CM undergoing heart transplantation. There is ongoing research seeking improvement in treatment options and outcomes for patients with this deadly disease. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  8. Early warnings of heart rate deterioration

    OpenAIRE

    Almeida, Vânia G.; Nabney, Ian T.

    2016-01-01

    Hospitals can experience difficulty in detecting and responding to early signs of patient deterioration leading to late intensive care referrals, excess mortality and morbidity, and increased hospital costs. Our study aims to explore potential indicators of physiological deterioration by the analysis of vital-signs. The dataset used comprises heart rate (HR) measurements from MIMIC II waveform database, taken from six patients admitted to the Intensive Care Unit (ICU) and diagnosed with sever...

  9. Total Artificial Heart Implantation after Excision of Right Ventricular Angiosarcoma.

    Science.gov (United States)

    Bruckner, Brian A; Abu Saleh, Walid K; Al Jabbari, Odeaa; Copeland, Jack G; Estep, Jerry D; Loebe, Matthias; Reardon, Michael J

    2016-06-01

    Primary cardiac sarcomas, although rare, are aggressive and lethal, requiring thorough surgical resection and adjuvant chemotherapy for the best possible outcome. We report the case of a 32-year-old woman who underwent total artificial heart implantation for right-sided heart failure caused by right ventricular angiosarcoma. For the first several weeks in intensive care, the patient recovered uneventfully. However, a postoperative liver biopsy indicated hepatocellular injury consistent with preoperative chemotherapy. She developed continuing liver failure, from which she died despite good cardiac function.

  10. High readmission rate after heart valve surgery

    DEFF Research Database (Denmark)

    Sibilitz, K L; Berg, S K; Thygesen, L C

    2015-01-01

    investigated. RESULTS: After valve surgery, the self-reported health was lower (Short Form-36 (SF-36) Physical Component Scale (PCS): 44.5 vs. 50.6 and Mental Component Scale (MCS): 51.9 vs. 55.0, pClinical signs......BACKGROUND: After heart valve surgery, knowledge on long-term self-reported health status and readmission is lacking. Thus, the optimal strategy for out-patient management after surgery remains unclear. METHODS: Using a nationwide survey with linkage to Danish registers with one year follow-up, we...... included all adults 6-12months after heart valve surgery irrespective of valve procedure, during Jan-June 2011 (n=867). Participants completed a questionnaire regarding health-status (n=742), and answers were compared with age- and sex-matched healthy controls. Readmission rates and mortality were...

  11. Clinical associations of total kidney volume: the Framingham Heart Study.

    Science.gov (United States)

    Roseman, Daniel A; Hwang, Shih-Jen; Oyama-Manabe, Noriko; Chuang, Michael L; O'Donnell, Christopher J; Manning, Warren J; Fox, Caroline S

    2017-08-01

    Total kidney volume (TKV) is an imaging biomarker that may have diagnostic and prognostic utility. The relationships between kidney volume, renal function and cardiovascular disease (CVD) have not been characterized in a large community-dwelling population. This information is needed to advance the clinical application of TKV. We measured TKV in 1852 Framingham Heart Study participants (mean age 64.1 ± 9.2 years, 53% women) using magnetic resonance imaging. A healthy sample was used to define reference values. The associations between TKV, renal function and CVD risk factors were determined using multivariable logistic regression analysis. Overall, mean TKV was 278 ± 54 cm3 for women and 365 ± 66 cm3 for men. Risk factors for high TKV (>90% healthy referent size) were body surface area (BSA), diabetes, smoking and albuminuria, while age, female and estimated glomerular filtration rate (eGFR) kidney damage including albuminuria and eGFR <60 mL/min/1.73 m2, while high TKV is associated with diabetes and decreased odds of eGFR <60 mL/min/1.73 m2. Prospective studies are needed to characterize the natural progression and clinical consequences of TKV. Published by Oxford University Press on behalf of ERA-EDTA 2016. This work is written by US Government employees and is in the public domain in the US.

  12. Total Artificial Heart Implantation Blood Pressure Management as Resolving Treatment for Massive Hemolysis following Total Artificial Heart Implantation.

    Science.gov (United States)

    Ghodsizad, Ali; Koerner, Michael M; El-Banayosy, A; Zeriouh, Mohamed; Ruhparwar, Arjang; Loebe, Matthias

    2016-10-21

    The SynCardia Total Artificial Heart (TAH) has been used for patients with biventricular failure, who cannot be managed with implantation of a left ventricular (LV) assist device. Following TAH implantation, our patient developed severe hemolysis, which could only be managed successfully by aggressive blood pressure control [Ohashi 2003; Nakata 1998].

  13. Total lymphatic irradiation and bone marrow in human heart transplantation

    International Nuclear Information System (INIS)

    Kahn, D.R.; Hong, R.; Greenberg, A.J.; Gilbert, E.F.; Dacumos, G.C.; Dufek, J.H.

    1984-01-01

    Six patients, aged 36 to 59 years, had heart transplants for terminal myocardial disease using total lymphatic irradiation (TLI) and donor bone marrow in addition to conventional therapy. All patients were poor candidates for transplantation because of marked pulmonary hypertension, unacceptable tissue matching, or age. Two patients are living and well more than four years after the transplants. Two patients died of infection at six and seven weeks with normal hearts. One patient, whose preoperative pulmonary hypertension was too great for an orthotopic heart transplant, died at 10 days after such a procedure. The other patient died of chronic rejection seven months postoperatively. Donor-specific tolerance developed in 2 patients. TLI and donor bone marrow can produce specific tolerance to donor antigens and allow easy control of rejection, but infection is still a major problem. We describe a new technique of administering TLI with early reduction of prednisone that may help this problem

  14. Machines versus medication for biventricular heart failure: focus on the total artificial heart.

    Science.gov (United States)

    Arabia, Francisco A; Moriguchi, Jaime D

    2014-09-01

    The medical/surgical management of advanced heart failure has evolved rapidly over the last few decades. With better understanding of heart failure pathophysiology, new pharmacological agents have been introduced that have resulted in improvements in survival. For those patients that fail to improve, mechanical circulatory support with left ventricular assist devices and total artificial hearts (TAHs) have served as a beneficial bridge to transplantation. The TAH has continued to play a significant role as a bridge to transplantation in patients with biventricular failure and more selected indications that could not be completely helped with left ventricular assist devices. Improved survival with the TAH has resulted in more patients benefiting from this technology. Improvements will eventually lead to a totally implantable device that will permanently replace the failing human heart.

  15. The mitochondrial uniporter controls fight or flight heart rate increases.

    Science.gov (United States)

    Wu, Yuejin; Rasmussen, Tyler P; Koval, Olha M; Joiner, Mei-Ling A; Hall, Duane D; Chen, Biyi; Luczak, Elizabeth D; Wang, Qiongling; Rokita, Adam G; Wehrens, Xander H T; Song, Long-Sheng; Anderson, Mark E

    2015-01-20

    Heart rate increases are a fundamental adaptation to physiological stress, while inappropriate heart rate increases are resistant to current therapies. However, the metabolic mechanisms driving heart rate acceleration in cardiac pacemaker cells remain incompletely understood. The mitochondrial calcium uniporter (MCU) facilitates calcium entry into the mitochondrial matrix to stimulate metabolism. We developed mice with myocardial MCU inhibition by transgenic expression of a dominant-negative (DN) MCU. Here, we show that DN-MCU mice had normal resting heart rates but were incapable of physiological fight or flight heart rate acceleration. We found that MCU function was essential for rapidly increasing mitochondrial calcium in pacemaker cells and that MCU-enhanced oxidative phoshorylation was required to accelerate reloading of an intracellular calcium compartment before each heartbeat. Our findings show that MCU is necessary for complete physiological heart rate acceleration and suggest that MCU inhibition could reduce inappropriate heart rate increases without affecting resting heart rate.

  16. Heart-Rate Variability—More than Heart Beats?

    Directory of Open Access Journals (Sweden)

    Gernot Ernst

    2017-09-01

    Full Text Available Heart-rate variability (HRV is frequently introduced as mirroring imbalances within the autonomous nerve system. Many investigations are based on the paradigm that increased sympathetic tone is associated with decreased parasympathetic tone and vice versa. But HRV is probably more than an indicator for probable disturbances in the autonomous system. Some perturbations trigger not reciprocal, but parallel changes of vagal and sympathetic nerve activity. HRV has also been considered as a surrogate parameter of the complex interaction between brain and cardiovascular system. Systems biology is an inter-disciplinary field of study focusing on complex interactions within biological systems like the cardiovascular system, with the help of computational models and time series analysis, beyond others. Time series are considered surrogates of the particular system, reflecting robustness or fragility. Increased variability is usually seen as associated with a good health condition, whereas lowered variability might signify pathological changes. This might explain why lower HRV parameters were related to decreased life expectancy in several studies. Newer integrating theories have been proposed. According to them, HRV reflects as much the state of the heart as the state of the brain. The polyvagal theory suggests that the physiological state dictates the range of behavior and psychological experience. Stressful events perpetuate the rhythms of autonomic states, and subsequently, behaviors. Reduced variability will according to this theory not only be a surrogate but represent a fundamental homeostasis mechanism in a pathological state. The neurovisceral integration model proposes that cardiac vagal tone, described in HRV beyond others as HF-index, can mirror the functional balance of the neural networks implicated in emotion–cognition interactions. Both recent models represent a more holistic approach to understanding the significance of HRV.

  17. Heart-Rate Variability-More than Heart Beats?

    Science.gov (United States)

    Ernst, Gernot

    2017-01-01

    Heart-rate variability (HRV) is frequently introduced as mirroring imbalances within the autonomous nerve system. Many investigations are based on the paradigm that increased sympathetic tone is associated with decreased parasympathetic tone and vice versa . But HRV is probably more than an indicator for probable disturbances in the autonomous system. Some perturbations trigger not reciprocal, but parallel changes of vagal and sympathetic nerve activity. HRV has also been considered as a surrogate parameter of the complex interaction between brain and cardiovascular system. Systems biology is an inter-disciplinary field of study focusing on complex interactions within biological systems like the cardiovascular system, with the help of computational models and time series analysis, beyond others. Time series are considered surrogates of the particular system, reflecting robustness or fragility. Increased variability is usually seen as associated with a good health condition, whereas lowered variability might signify pathological changes. This might explain why lower HRV parameters were related to decreased life expectancy in several studies. Newer integrating theories have been proposed. According to them, HRV reflects as much the state of the heart as the state of the brain. The polyvagal theory suggests that the physiological state dictates the range of behavior and psychological experience. Stressful events perpetuate the rhythms of autonomic states, and subsequently, behaviors. Reduced variability will according to this theory not only be a surrogate but represent a fundamental homeostasis mechanism in a pathological state. The neurovisceral integration model proposes that cardiac vagal tone, described in HRV beyond others as HF-index, can mirror the functional balance of the neural networks implicated in emotion-cognition interactions. Both recent models represent a more holistic approach to understanding the significance of HRV.

  18. Multigated radionuclide study of the total artificial heart

    International Nuclear Information System (INIS)

    Datz, F.L.; Christian, P.E.; Taylor, A. Jr.; Hastings, W.L.; De Vries, W.C.

    1987-01-01

    A permanent total artificial heart, the Jarvik-7, was implanted into a 61-year-old male with a severe cardiomyopathy. Gated radionuclide studies were performed in the patient both prior to surgery and following implantation. Preoperative gated radionuclide cardiac studies revealed marked left ventricular enlargement, severe hypokinesis and a left ventricular ejection fraction of 10%. The right ventricle was moderately enlarged with a 27% ejection fraction. Following implantation of the Jarvik-7 artificial heart, gated cardiac studies were performed with a computer gated by a signal from the heart controller. The left ventricular ejection fraction was 69% and the right ventricular ejection fraction was 62%. This compared to a theoretical ejection fraction of 74% for each ventricle based on chamber anatomy. There was excellent ventricular emptying. Phase analysis showed uniform diaphragm motion. The use of gated cardiac studies in humans may prove helpful in evaluating mechanical problems with the artificial heart, such as manlfunction of the diaphragm, before they become clinically apparent. (orig.)

  19. Successful heart transplant after 1374 days living with a total artificial heart.

    Science.gov (United States)

    Gerosa, Gino; Gallo, Michele; Bottio, Tomaso; Tarzia, Vincenzo

    2016-04-01

    The CardioWest Total Artificial Heart (CW-TAH) has been approved as a temporary device for bridge to cardiac transplantation and is under investigation for destination therapy by US Food and Drug Administration (FDA). We herein report the longest worldwide survival out of hospital (1374 days) of a patient supported with Cardio West Total Artificial Heart (CW-TAH). This experience is intended as a proof of concept of using CW-TAH as the destination therapy in patients with biventricular failure. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.

    Science.gov (United States)

    Pelletier, Benedikt; Spiliopoulos, Sotirios; Finocchiaro, Thomas; Graef, Felix; Kuipers, Kristin; Laumen, Marco; Guersoy, Dilek; Steinseifer, Ulrich; Koerfer, Reiner; Tenderich, Gero

    2015-01-01

    Owing to the lack of suitable allografts, the demand for long-term mechanical circulatory support in patients with biventricular end-stage heart failure is rising. Currently available Total Artificial Heart (TAH) systems consist of pump units with only limited durability, percutaneous tubes and bulky external equipment that limit the quality of life. Therefore we are focusing on the development of a fully implantable, highly durable destination therapy total artificial heart. The ReinHeart-TAH system consists of a passively filling pump unit driven by a low-wear linear drive between two artificial ventricles, an implantable control unit and a compliance chamber. The TAH is powered by a transcutaneous energy transmission system. The flow distribution inside the ventricles was analysed by fluid structure interaction simulation and particle image velocimetry measurements. Along with durability tests, the hydrodynamic performance and flow balance capability were evaluated in a mock circulation loop. Animal trials are ongoing. Based on fluid structure interaction simulation and particle image velocimetry, blood stagnation areas have been significantly reduced. In the mock circulation loop the ReinHeart-TAH generated a cardiac output of 5 l/min at an operating frequency of 120 bpm and an aortic pressure of 120/80 mmHg. The highly effective preload sensitivity of the passively filling ventricles allowed the sensorless integration of the Frank Starling mechanism. The ReinHeart-TAH effectively replaced the native heart's function in animals for up to 2 days. In vitro and in vivo testing showed a safe and effective function of the ReinHeart-TAH system. This has the potential to become an alternative to transplantation. However, before a first-in-man implant, chronic animal trials still have to be completed. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Heart rate awareness in patients with chronic stable heart failure. A multi-center observational study.

    LENUS (Irish Health Repository)

    Moran, D

    2014-08-23

    We assessed adherence to European Society of Cardiology heart rate guidelines (i.e. heart rates less than 70bpm) in patients with chronic stable heart failure. We also investigated the percent of patients on target doses of rate controlling drugs.

  2. Heart and soul: heart rate variability and major depression.

    Science.gov (United States)

    Kidwell, Meyrick; Ellenbroek, Bart A

    2018-04-01

    There is a bidirectional relationship between affective disorders and cardiovascular abnormalities, often described as a downward spiral, whereas major depressive disorders (MDD, and anxiety disorders) significantly increase the risk of developing cardiovascular diseases (CVD); CVD are also associated with increased risk of developing MDD (and anxiety disorders). Moreover, the prognosis and progression of CVD is significantly worsened in the presence of MDD. Heart rate variability (HRV) has often been suggested as a potential mediator in this comorbidity. In this review, we discuss HRV alterations in MDD. However, we mainly focus on the direct relationship between HRV alterations and psychiatric symptoms, rather than its relationship with CVD, as this has been reviewed elsewhere. After a general introduction to HRV and how it can be measured, we review how HRV is altered in MDD. We subsequently describe how antidepressant drugs affect HRV, showing that some classes (such as tricyclics) generally worsen HRV, whereas others (most notably selective serotonin reuptake inhibitors) have a more positive influence. We also review the effects of several other treatments, with a special focus on vagal nerve stimulation, finishing with some further considerations and recommendation for further research, both in humans and animals.

  3. The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    Science.gov (United States)

    Glynn, Jeremy; Song, Howard; Hull, Bryan; Withers, Stanley; Gelow, Jill; Mudd, James; Starr, Albert; Wampler, Richard

    2017-10-01

    Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles between two positions to provide pulsatile, alternating blood flow to the systemic and pulmonary circulations without artificial valves. Flow rates and pressures generated by the TAH are controlled by adjusting rotor speed, cycle frequency, and the proportion of each cycle spent pumping to either circulation. To validate the design, a TAH prototype was placed in a mock circulatory loop that simulates vascular resistance, pressure, and compliance in normal and pathophysiologic conditions. At a systemic blood pressure of 120/80 mm Hg, nominal TAH output was 7.4 L/min with instantaneous flows reaching 17 L/min. Pulmonary artery, and left and right atrial pressures were all maintained within normal ranges. To simulate implant into a patient with severe pulmonary hypertension, the pulmonary vascular resistance of the mock loop was increased to 7.5 Wood units. By increasing pump speed to the pulmonary circulation, cardiac output could be maintained at 7.4 L/min as mean pulmonary artery pressure increased to 56 mm Hg while systemic blood pressures remained normal. This in vitro testing of a novel, shuttling TAH demonstrated that cardiac output could be maintained across a range of pathophysiologic conditions including pulmonary hypertension. These experiments serve as a proof-of-concept for the design, which has proceeded to in vivo testing. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. Changes in heart rate and heart rate variability as a function of age in Thoroughbred horses.

    Science.gov (United States)

    Ohmura, Hajime; Jones, James H

    2017-01-01

    We investigated changes in heart rate (HR) and HR variability as a function of age in newborn foals to old Thoroughbred horses. Experiments were performed on a total of 83 healthy and clinically normal Thoroughbred horses. Resting HR decreased with age from birth. The relationship between age and HR fit the equation Y=48.2X -0.129 (R 2 =0.705); the relationship between age and HR for horses 0-7 years old fit the equation Y=44.1X -0.179 (R 2 =0.882). Seven-day-old horses had the highest HR values (106 ± 10.3 beat/min). The low frequency (LF) and high frequency (HF) powers increased with age in newborn to old horses. These changes in HR and HR variability appear to result from the effects of ageing. Three- to seven-year-old race horses had the lowest HR values (32.9 ± 3.5 beat/min) and the highest LF and HF powers except for the HF powers in the oldest horses. Race training may have contributed to these changes. Horses of ages greater than 25 years old had the highest HF powers and the lowest LF/HF ratios. In individual horses, 8 of the 15 horses over 25 years old had LF/HF ratios of less than 1.0; their HR variability appears to be unique, and they may have a different autonomic balance than horses of younger age.

  5. Gender differences of heart rate variability in healthy volunteers

    International Nuclear Information System (INIS)

    Saleem, S.; Majeed, S.M.I.; Khan, M.A.

    2012-01-01

    Objective: To identify the basic values of heart rate variability in Pakistani population and to verify our hypothesis that there are gender differences in cardiovascular autonomic modulation. Methods: The descriptive cross sectional study based on convenience probability sampling was conducted at Armed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD) Pakistan. The duration of the study was from December 2009 to July 2010. It involved 24-hour holter monitoring of 45 healthy individuals using holter electrocardiography (ECG) recorder. Heart rate variability was analysed in time (SDNN, SDANN, SDNNi, rMSSD, pNN50) and frequency domains (power, VLF, LF, and HF). Results: The time domain indices; SDNN (male=140 +- 36 ms vs. females=122 +- 33 ms; p =0.09), SDANN (male=123 +- 34 ms vs. females=111+- 34 ms; P= 0.23), SDNNi (male=64 +-19 ms vs. females=52 +- 14 ms; P= 0.03), and pNN50 (male=14 +- 10 ms vs. females=12 +- 7 ms; P= 0.43) were decreased in female volunteers when compared with males. Comparison of frequency domain indices; Total power (male=4041 +- 3150 ms/sup 2/ vs. females=2750 +- 1439 ms/sup 2/; P= 0.07), VLF (male=291 2675 ms/sup 2/ vs. females=1843 +- 928 ms/sup 2/; P= 0.06), LF (male=788 +- 397 ms/sup 2/ vs. females=556 +- 346 ms/sup 2/; P= 0.04) and HF (male=318 +- 251 ms/sup 2/ vs. females=31 277 ms/sup 2/; P= 0.94) amongst males and females showed attenuated heart rate variability in females. Of all the observed values, SDNNi and LF were found significantly (p <0.05) decreased in women. Conclusion: In healthy population, heart rate variability is low in women than men. It reflects sympathetic dominance in women in our population. (author)

  6. Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.

    Science.gov (United States)

    Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel

    2018-03-01

    Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).

  7. Heart Rate Changes in Electroacupuncture Treated Polycystic Ovary in Rats.

    Science.gov (United States)

    Ramadoss, Mukilan; Ramanathan, Gunasekaran; Subbiah, Angelie Jessica; Natrajan, Chidambaranathan

    2016-03-01

    Polycystic Ovary Syndrome (PCOS) is a common metabolic disorder, it affects both humans and animals. It may induce coronary heart disease, obesity and hyperandrogenism. Previous studies show that Low frequency Electroacupuncture (EA) have an effect on PCOS, however the exact pathway is unclear. To find the effect of EA on autonomic activity of the heart in Estradiol Valerate (EV) induced PCOS rats. Heart rate variability (HRV) was assessed in 3 groups: 1) Control; 2) PCOS rats; and 3) PCOS rats after EA treatment (n=8 in each group). From the time domain analysis and frequency domain analysis (linear measures) HRV analysis was done. EA stimulation was given at low frequency of 2Hz for 15 min on alternate days for 4-5 weeks. Collected data were statistically analysed using One-Way Analysis of Variance with the application of multiple comparisons of Tukey test. EA treatment group shows significant reduction in Heart Rate (HR) and low frequency, high frequency ratio (LF/HF); and increase in RR interval, Total Power (TP) when compared to PCOS group. The study concludes that EA treatment has a significant effect on reducing sympathetic tone and decreasing HR in PCOS.

  8. Increased heart rate variability during nondirective meditation.

    Science.gov (United States)

    Nesvold, Anders; Fagerland, Morten W; Davanger, Svend; Ellingsen, Øyvind; Solberg, Erik E; Holen, Are; Sevre, Knut; Atar, Dan

    2012-08-01

    Meditation practices are in use for relaxation and stress reduction. Some studies indicate beneficial cardiovascular health effects of meditation. The effects on the autonomous nervous system seem to vary among techniques. The purpose of the present study was to identify autonomic nerve activity changes during nondirective meditation. Heart rate variability (HRV), blood pressure variability (BPV), and baroreflex sensitivity (BRS) were monitored in 27 middle-aged healthy participants of both genders, first during 20 min regular rest with eyes closed, thereafter practising Acem meditation for 20 min. Haemodynamic and autonomic data were collected continuously (beat-to-beat) and non-invasively. HRV and BPV parameters were estimated by power spectral analyses, computed by an autoregressive model. Spontaneous activity of baroreceptors were determined by the sequence method. Primary outcomes were changes in HRV, BPV, and BRS between rest and meditation. HRV increased in the low-frequency (LF) and high-frequency (HF) bands during meditation, compared with rest (p = 0.014, 0.013, respectively). Power spectral density of the RR-intervals increased as well (p = 0.012). LF/HF ratio decreased non-significantly, and a reduction of LF-BPV power was observed during meditation (p < 0.001). There was no significant difference in BRS. Respiration and heart rates remained unchanged. Blood pressure increased slightly during meditation. There is an increased parasympathetic and reduced sympathetic nerve activity and increased overall HRV, while practising the technique. Hence, nondirective meditation by the middle aged may contribute towards a reduction of cardiovascular risk.

  9. Influence of heavy cigarette smoking on heart rate variability and heart rate turbulence parameters

    DEFF Research Database (Denmark)

    Cagirci, Goksel; Cay, Serkan; Karakurt, Ozlem

    2009-01-01

    BACKGROUND: Cigarette smoking increases the risk of cardiovascular events related with several mechanisms. The most suggested mechanism is increased activity of sympathetic nervous system. Heart rate variability (HRV) and heart rate turbulence (HRT) has been shown to be independent and powerful......, 69 subjects and nonsmokers 74 subjects (control group) were enrolled in this study. HRV and HRT analyses [turbulence onset (TO) and turbulence slope (TS)] were assessed from 24-hour Holter recordings. RESULTS: The values of TO were significantly higher in heavy cigarette smokers than control group...... (-1.150 +/- 4.007 vs -2.454 +/- 2.796, P = 0.025, respectively), but values of TS were not statistically different between two groups (10.352 +/- 7.670 vs 9.613 +/- 7.245, P = 0.555, respectively). Also, the number of patients who had abnormal TO was significantly higher in heavy cigarette smokers...

  10. Genome-wide association studies and resting heart rate

    DEFF Research Database (Denmark)

    Oskari Kilpeläinen, Tuomas

    2016-01-01

    Genome-wide association studies (GWASs) have revolutionized the search for genetic variants regulating resting heart rate. In the last 10 years, GWASs have led to the identification of at least 21 novel heart rate loci. These discoveries have provided valuable insights into the mechanisms...... and pathways that regulate heart rate and link heart rate to cardiovascular morbidity and mortality. GWASs capture majority of genetic variation in a population sample by utilizing high-throughput genotyping chips measuring genotypes for up to several millions of SNPs across the genome in thousands...... of individuals. This allows the identification of the strongest heart rate associated signals at genome-wide level. While GWASs provide robust statistical evidence of the association of a given genetic locus with heart rate, they are only the starting point for detailed follow-up studies to locate the causal...

  11. Heart rate variability interventions for concussion and rehabilitation

    OpenAIRE

    Conder, Robert L.; Conder, Alanna A.

    2014-01-01

    The study of Heart Rate Variability (HRV) has emerged as an essential component of cardiovascular health, as well as a physiological mechanism by which one can increase the interactive communication between the cardiac and the neurocognitive systems (i.e., the body and the brain). It is well-established that lack of heart rate variability implies cardiopathology, morbidity, reduced quality-of-life, and precipitous mortality. On the positive, optimal heart rate variability has been associated ...

  12. Playing a violent television game affects heart rate variability.

    Science.gov (United States)

    Ivarsson, Malena; Anderson, Martin; Akerstedt, Torbjörn; Lindblad, Frank

    2009-01-01

    To investigate how playing a violent/nonviolent television game during the evening affects sympathetic and parasympathetic reactions during and after playing as well as sleep quality during the night after playing. In total, 19 boys, 12-15 years of age, played television games on two occasions in their homes and participated once without gaming. Heart rate, heart rate variability (HRV) and physical activity were measured during gaming/participating and the night to follow using a portable combined heart rate and movement sensor. A sleep diary and questionnaires about gaming experiences and session-specific experiences were filled in. Criteria for Selection of Games: Violent game involves/rewards direct physical violence (no handguns) against another person, and nonviolent game involves/rewards no violence; same game design ('third-person game'); conducted in the same manner; no differences concerning motor activity; similar sound and light effects; no sexual content, violence against women or racial overtones. During violent (vs. nonviolent) gaming, there was significantly higher activity of the very low frequency component of the HRV and total power. During the night after playing, very low frequency, low frequency and high frequency components were significantly higher during the violent (vs. nonviolent) condition, just as total power. There were no significant differences between the three conditions (violent/nonviolent/no gaming) with respect to an index reflecting subjectively perceived sleep difficulties. Nor was there any difference between violent and nonviolent condition for any single sleep item. Violent gaming induces different autonomic responses in boys compared to nonviolent gaming--during playing and during the following night--suggesting different emotional responses. Subjectively perceived sleep quality is not influenced after a single gaming experience. Future studies should address the development of the autonomic balance after gaming over longer

  13. Cardiovascular Reactivity and Heart Rate Variability in Panic Disorder

    National Research Council Canada - National Science Library

    Santiago, Helen T

    1999-01-01

    .... Because previous studies of cardiovascular reactivity and heart rate variability have been inconclusive, these factors were re-examined in panickers and controls during physiological challenge...

  14. Drowsiness detection using heart rate variability.

    Science.gov (United States)

    Vicente, José; Laguna, Pablo; Bartra, Ariadna; Bailón, Raquel

    2016-06-01

    It is estimated that 10-30 % of road fatalities are related to drowsy driving. Driver's drowsiness detection based on biological and vehicle signals is being studied in preventive car safety. Autonomous nervous system activity, which can be measured noninvasively from the heart rate variability (HRV) signal obtained from surface electrocardiogram, presents alterations during stress, extreme fatigue and drowsiness episodes. We hypothesized that these alterations manifest on HRV and thus could be used to detect driver's drowsiness. We analyzed three driving databases in which drivers presented different sleep-deprivation levels, and in which each driving minute was annotated as drowsy or awake. We developed two different drowsiness detectors based on HRV. While the drowsiness episodes detector assessed each minute of driving as "awake" or "drowsy" with seven HRV derived features (positive predictive value 0.96, sensitivity 0.59, specificity 0.98 on 3475 min of driving), the sleep-deprivation detector discerned if a driver was suitable for driving or not, at driving onset, as function of his sleep-deprivation state. Sleep-deprivation state was estimated from the first three minutes of driving using only one HRV feature (positive predictive value 0.80, sensitivity 0.62, specificity 0.88 on 30 drivers). Incorporating drowsiness assessment based on HRV signal may add significant improvements to existing car safety systems.

  15. Early warnings of heart rate deterioration.

    Science.gov (United States)

    Almeida, Vania G; Nabney, Ian T

    2016-08-01

    Hospitals can experience difficulty in detecting and responding to early signs of patient deterioration leading to late intensive care referrals, excess mortality and morbidity, and increased hospital costs. Our study aims to explore potential indicators of physiological deterioration by the analysis of vital-signs. The dataset used comprises heart rate (HR) measurements from MIMIC II waveform database, taken from six patients admitted to the Intensive Care Unit (ICU) and diagnosed with severe sepsis. Different indicators were considered: 1) generic early warning indicators used in ecosystems analysis (autocorrelation at-1-lag (ACF1), standard deviation (SD), skewness, kurtosis and heteroskedasticity) and 2) entropy analysis (kernel entropy and multi scale entropy). Our preliminary findings suggest that when a critical transition is approaching, the equilibrium state changes what is visible in the ACF1 and SD values, but also by the analysis of the entropy. Entropy allows to characterize the complexity of the time series during the hospital stay and can be used as an indicator of regime shifts in a patient's condition. One of the main problems is its dependency of the scale used. Our results demonstrate that different entropy scales should be used depending of the level of entropy verified.

  16. Study Heart Rate by Tools from Complex Networks

    International Nuclear Information System (INIS)

    Makowiec, D.; Wdowczyk-Szulc, J.; Zarczynska-Buchowiecka, M.; Gruchala, M.; Rynkiewicz, A.

    2011-01-01

    Heart rate measured as beat-to-beat time intervals varies in time. It is believed that time intervals between subsequent normal heart contractions carry information about the regulatory system of the heart. How to quantify such signals is not clear and because of that heart rate variability is still apart from the clinic routine. In the following, we propose a method for representing a heart rate signal as a directed network. Then we study the signal properties by complex network tools. The signals to study were collected from patients recovering after the heart transplantation. The aim is to classify the progress of adapting of the new heart - graft. Moreover, it is expected that the method allows for visual classification. Our investigations are preliminary, however the obtained results are promising. (authors)

  17. Abnormal heart rate recovery and deficient chronotropic response after submaximal exercise in young Marfan syndrome patients.

    Science.gov (United States)

    Peres, Paulo; Carvalho, Antônio C; Perez, Ana Beatriz A; Medeiros, Wladimir M

    2016-10-01

    Marfan syndrome patients present important cardiac structural changes, ventricular dysfunction, and electrocardiographic changes. An abnormal heart rate response during or after exercise is an independent predictor of mortality and autonomic dysfunction. The aim of the present study was to compare heart rate recovery and chronotropic response obtained by cardiac reserve in patients with Marfan syndrome subjected to submaximal exercise. A total of 12 patients on β-blocker therapy and 13 off β-blocker therapy were compared with 12 healthy controls. They were subjected to submaximal exercise with lactate measurements. The heart rate recovery was obtained in the first minute of recovery and corrected for cardiac reserve and peak lactate concentration. Peak heart rate (141±16 versus 155±17 versus 174±8 bpm; p=0.001), heart rate reserve (58.7±9.4 versus 67.6±14.3 versus 82.6±4.8 bpm; p=0.001), heart rate recovery (22±6 versus 22±8 versus 34±9 bpm; p=0.001), and heart rate recovery/lactate (3±1 versus 3±1 versus 5±1 bpm/mmol/L; p=0.003) were different between Marfan groups and controls, respectively. All the patients with Marfan syndrome had heart rate recovery values below the mean observed in the control group. The absolute values of heart rate recovery were strongly correlated with the heart rate reserve (r=0.76; p=0.001). Marfan syndrome patients have reduced heart rate recovery and chronotropic deficit after submaximal exercise, and the chronotropic deficit is a strong determinant of heart rate recovery. These changes are suggestive of autonomic dysfunction.

  18. Pulmonary Hypertension After Heart Transplantation in Patients Bridged with the Total Artificial Heart.

    Science.gov (United States)

    Shah, Rachit; Patel, Dhavalkumar B; Mankad, Anit K; Rennyson, Stephen L; Tang, Daniel G; Quader, Mohammed A; Smallfield, Melissa C; Kasirajan, Vigneshwar; Shah, Keyur B

    2016-01-01

    Pulmonary hypertension (PH) among heart transplant recipients is associated with an increased risk of mortality. Pulmonary hemodynamics improves after left ventricular assist device (LVAD) implantation; however, the impact of PH before total artificial heart (TAH) implantation on posttransplant hemodynamics and survival is unknown. This is a single center retrospective study aimed to evaluate the impact of TAH implantation on posttransplant hemodynamics and mortality in two groups stratified according to severity of PH: high (≥3 Woods units [WU]) and low (heart catheterization performed at baseline (before TAH) and posttransplant at 1 and 12 months. Patients in the high PVR group (n = 12) experienced improvement in PVR (baseline = 4.31 ± 0.7; 1-month = 1.69 ± 0.7, p heart transplantation (HT), but remained elevated. There was no significant difference in survival between the two groups at 12 months follow-up. Patients with high PVR who are bridged to transplant with TAH had improvement in PVR at 12 months after transplant, and the degree of PVR did not impact posttransplant survival.

  19. A Physical Heart Failure Simulation System Utilizing the Total Artificial Heart and Modified Donovan Mock Circulation.

    Science.gov (United States)

    Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Betterton, Edward; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J

    2017-07-01

    With the growth and diversity of mechanical circulatory support (MCS) systems entering clinical use, a need exists for a robust mock circulation system capable of reliably emulating and reproducing physiologic as well as pathophysiologic states for use in MCS training and inter-device comparison. We report on the development of such a platform utilizing the SynCardia Total Artificial Heart and a modified Donovan Mock Circulation System, capable of being driven at normal and reduced output. With this platform, clinically relevant heart failure hemodynamics could be reliably reproduced as evidenced by elevated left atrial pressure (+112%), reduced aortic flow (-12.6%), blunted Starling-like behavior, and increased afterload sensitivity when compared with normal function. Similarly, pressure-volume relationships demonstrated enhanced sensitivity to afterload and decreased Starling-like behavior in the heart failure model. Lastly, the platform was configured to allow the easy addition of a left ventricular assist device (HeartMate II at 9600 RPM), which upon insertion resulted in improvement of hemodynamics. The present configuration has the potential to serve as a viable system for training and research, aimed at fostering safe and effective MCS device use. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Reduced intrinsic heart rate is associated with reduced arrhythmic susceptibility in guinea-pig heart.

    Science.gov (United States)

    Osadchii, Oleg E

    2014-12-01

    In the clinical setting, patients with slower resting heart rate are less prone to cardiovascular death compared with those with elevated heart rate. However, electrophysiological adaptations associated with reduced cardiac rhythm have not been thoroughly explored. In this study, relationships between intrinsic heart rate and arrhythmic susceptibility were examined by assessments of action potential duration (APD) rate adaptation and inducibility of repolarization alternans in sinoatrial node (SAN)-driven and atrioventricular (AV)-blocked guinea-pig hearts perfused with Langendorff apparatus. Electrocardiograms, epicardial monophasic action potentials, and effective refractory periods (ERP) were assessed in normokalemic and hypokalemic conditions. Slower basal heart rate in AV-blocked hearts was associated with prolonged ventricular repolarization during spontaneous beating, and with attenuated APD shortening at increased cardiac activation rates during dynamic pacing, when compared with SAN-driven hearts. During hypokalemic perfusion, the inducibility of repolarization alternans and tachyarrhythmia by rapid pacing was found to be lower in AV-blocked hearts. This difference was ascribed to prolonged ERP in the setting of reduced basal heart rate, which prevented ventricular capture at critically short pacing intervals required to induce arrhythmia. Reduced basal heart rate is associated with electrophysiological changes that prevent electrical instability upon an abrupt cardiac acceleration.

  1. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei [Texas Children' s Hospital, E. B. Singleton Department of Pediatric Radiology, Houston, TX (United States); Bogale, Saivivek [Baylor University Medical Center, Department of Radiology, Dallas, TX (United States); Golriz, Farahnaz [Baylor College of Medicine, Department of Radiology, Houston, TX (United States); Krishnamurthy, Rajesh [Nationwide Children' s Hospital, Department of Diagnostic Radiology, Columbus, OH (United States)

    2017-11-15

    Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole. (orig.)

  2. Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

    Science.gov (United States)

    Buxton, Roxanne E.; West, Michael R.; Kalogera, Kent L.; Hanson, Andrea M.

    2016-01-01

    Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth® heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an

  3. The 50/50 cc Total Artificial Heart Trial: Extending the Benefits of the Total Artificial Heart to Underserved Populations.

    Science.gov (United States)

    Wells, Dennis; Villa, Chet R; Simón Morales, David Luís

    2017-01-01

    While use of the total artificial heart (TAH) is growing, the use of the device is not uniform across the gender and age spectrum because the vast majority of implants are in adult males. SynCardia has recently developed a smaller 50 cc TAH that was designed to accommodate patients with a body surface area as low as 1.2 m 2 (potentially even lower using virtual implantation). Herein, we describe the early use of the 50 cc TAH (10 implants in the US and 18 outside the US). Twenty-eight devices have been implanted worldwide. Nineteen (68%) patients were female, 4 (14%) were 21 years of age or younger, and 2 (7%) had a diagnosis of congenital heart disease (1 Fontan). The smallest patient, by body surface area, was 1.35 m 2 . Six patients (21%) have been placed on the Freedom Driver, all of whom have survived. Fourteen patients (50%) have had a positive outcome to date. The development of the 50 cc TAH has expanded the population of patients who may benefit from TAH support and thus may help improve outcomes for patients who have had limited biventricular support options to date. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. First North American 50 cc Total Artificial Heart Experience: Conversion from a 70 cc Total Artificial Heart.

    Science.gov (United States)

    Khalpey, Zain; Kazui, Toshinobu; Ferng, Alice S; Connell, Alana; Tran, Phat L; Meyer, Mark; Rawashdeh, Badi; Smith, Richard G; Sweitzer, Nancy K; Friedman, Mark; Lick, Scott; Slepian, Marvin J; Copeland, Jack G

    2016-01-01

    The 70 cc total artificial heart (TAH) has been utilized as bridge to transplant (BTT) for biventricular failure. However, the utilization of 70 cc TAH has been limited to large patients for the low output from the pulmonary as well as systemic vein compression after chest closure. Therefore, the 50 cc TAH was developed by SynCardia (Tucson, AZ) to accommodate smaller chest cavity. We report the first TAH exchange from a 70 to 50 cc due to a fit difficulty. The patient failed to be closed with a 70 cc TAH, although the patient met the conventional 70 cc TAH fit criteria. We successfully closed the chest with a 50 cc TAH.

  5. Do high fetal catecholamine levels affect heart rate variability and ...

    African Journals Online (AJOL)

    Objectives. To deternrine the relationship between Umbilical arterial catecholamine levels and fetal heart rate variability and meconium passage. Study design. A prospective descriptive study was perfonned. Umbilical artery catecholamine levels were measured in 55 newborns and correlated with fetal heart rate before ...

  6. Effects of Malaria on Blood Pressure, Heart Rate, Electrocardiogram ...

    African Journals Online (AJOL)

    The effect of malaria on blood pressure, heart rate, electrocardiogram and the cardiovascular responses to postural change were studied in malaria patients. Blood pressure was measured by the sphygmomanometric-auscultatory method. Standard ECG machine was used to record the electrocardiogram. Heart rate was ...

  7. Reconstructed image of human heart for total artificial heart implantation, based on MR image and cast silicone model of heart

    International Nuclear Information System (INIS)

    Komoda, Takashi; Maeta, Hajime; Uyama, Chikao.

    1991-01-01

    Based on transverse (TRN) and LV long axis (LAX) MR images of two cadaver hearts, three-dimensional (3-D) computer models of the connecting interface between remaining heart and total artificial heart, i.e., mitral and tricuspid valvular annuli (MVA and TVA), ascending aorta (Ao) and pulmonary artery (PA), were reconstructed to compare the shape and the size of MVA and those of TVA, the distance between the center of MVA and TVA (D G ), the angle between the plane of MVA and that of TVA (R T ), and the angles of Ao and PA, respectively, to the plane of MVA (R A , R P ), with those obtained in cast silicone models. It was found that based on LAX rather than TRN MR image, MVA and TVA might be more precisely reconstructed. The data obtained in 3-D images of MVA, TVA, Ao and PA based on silicone models of 32 hearts were as follows: D G (cm): 4.17±0.43, R T (degrees): 22.1±11.3, R A (degrees): 54.9±15.3, R P (degrees): 30.8±17.1. (author)

  8. The clinical significance of detection to heart rate deceleration capacity and heart rate variability in patients with chronic heart failure

    Directory of Open Access Journals (Sweden)

    Jiang-rong Zhou

    2015-01-01

    Full Text Available Objective: To study the change of heart rate deceleration capacity ( DC and heart rate variability in patients with chronic heart failure (CHF and its relationship with left ventricular ejection fraction (LVEF. Methods: DC, LVEF, time and frequency domain parameters of HRV were measured in 66 patients with CHF and 34 healthy adults (control group by using 24h Holter recordings and Echocardiography. The standard deviation of normal R-R intervals( SDNN, squares of differences between adjacent NN intervals ( RMSSD,low frequency power( LFn and high frequency power( HFn and the changes of LVEF were compared between  the two groups,the relationship between DC,LVEF and HRV were studied in patients with CHF. Results: The median value of DC in the patients with CHF was significantly lower than that in control group( 3.1 ± 2.4 ms vs 7.2 ± 1.3 ms,P <0.01.Incidence of abnormal DC in the CHF group was 57.5%,which was significantly higher than that in the control group (P <0.01.The HRV index, including SDNN、RMSSD、LFn、HFn, in the CHF group was significantly lower than that in normal control group (P < 0.01. Significant positive correlation between HRV index and LVEF were confirmed (P < 0.01. Conclusions: DC and HRV index are lower in patients with CHF and have a good correlation with the left ventricular ejection fraction.

  9. Total Artificial Heart as Bridge to Heart Transplantation in Chagas Cardiomyopathy: Case Report.

    Science.gov (United States)

    Ruzza, A; Czer, L S C; De Robertis, M; Luthringer, D; Moriguchi, J; Kobashigawa, J; Trento, A; Arabia, F

    2016-01-01

    Chagas disease (CD) is becoming an increasingly recognized cause of dilated cardiomyopathy outside of Latin America, where it is endemic, due to population shifts and migration. Heart transplantation (HTx) is a therapeutic option for end-stage cardiomyopathy due to CD, but may be considered a relative contraindication due to potential reactivation of the causative organism with immunosuppression therapy. The total artificial heart (TAH) can provide mechanical circulatory support in decompensated patients with severe biventricular dysfunction until the time of HTx, while avoiding immunosuppressive therapy and removing the organ most affected by the causative organism. We report herein a patient with CD and severe biventricular dysfunction, who had mechanical circulatory support with a TAH for more than 6 months, followed by successful orthotopic HTx and treatment with benznidazole for 3 months. The patient had no evidence of recurrent disease in the transplanted heart based on endomyocardial biopsy up to 1 year post-transplantation, and remains alive more than 30 months after insertion of a TAH and 24 months after HTx. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Cycling cadence affects heart rate variability

    International Nuclear Information System (INIS)

    Lunt, Heather C; Corbett, Jo; Barwood, Martin J; Tipton, Michael J

    2011-01-01

    The purpose of this study was to examine the effect different cycling cadences have on heart rate variability (HRV) when exercising at constant power outputs. Sixteen males had ECG and respiratory measurements recorded at rest and during 8, 10 min periods of cycling at four different cadences (40, 60, 80 and 100 revs min −1 ) and two power outputs (0 W (unloaded) and 100 W (loaded)). The cycling periods were performed following a Latin square design. Spectral analyses of R–R intervals by fast Fourier transforms were used to quantify absolute frequency domain HRV indices (ms 2 ) during the final 5 min of each bout, which were then log transformed using the natural logarithm (Ln). HRV indices of high frequency (HF) power were reduced when cadence was increased (during unloaded cycling (0 W) log transformed HF power decreased from a mean [SD] of 6.3 [1.4] Ln ms 2 at 40 revs min −1 to 3.9 [1.3] Ln ms 2 at 100 revs min −1 ). During loaded cycling (at 100 W), the low to high frequency (LF:HF) ratio formed a 'J' shaped curve as cadence increased from 40 revs min −1 (1.4 [0.4]) to 100 revs min −1 (1.9 [0.7]), but dipped below the 40 revs min −1 values during the 60 revs min −1 1.1 (0.3) and 80 revs min −1 1.2 (0.6) cadence conditions. Cardiac frequency (f C ) and ventilatory variables were strongly correlated with frequency domain HRV indices (r = −0.80 to −0.95). It is concluded that HRV indices are influenced by both cycling cadence and power output; this is mediated by the f C and ventilatory changes that occur as cadence or exercise intensity is increased. Consequently, if HRV is assessed during exercise, both power output/exercise intensity and cadence should be standardized

  11. Detailed heart rate variability analysis in athletes.

    Science.gov (United States)

    Kiss, Orsolya; Sydó, Nóra; Vargha, Péter; Vágó, Hajnalka; Czimbalmos, Csilla; Édes, Eszter; Zima, Endre; Apponyi, Györgyi; Merkely, Gergő; Sydó, Tibor; Becker, Dávid; Allison, Thomas G; Merkely, Béla

    2016-08-01

    Heart rate variability (HRV) analysis has been used to evaluate patients with various cardiovascular diseases. While the vast majority of HRV studies have focused on pathological states, our study focuses on the less explored area of HRV analysis across different training intensity and sports. We aimed to measure HRV in healthy elite and masters athletes and compare to healthy, but non-athletic controls. Time-domain HRV analysis was applied in 138 athletes (male 110, age 28.4 ± 8.3) and 100 controls (male 56, age 28.3 ± 6.9) during Holter monitoring (21.3 ± 3.0 h). All studied parameters were higher in elite athletes compared to controls [SDNN (CI) 225.3 (216.2-234.5) vs 158.6 (150.2-167.1) ms; SDNN Index (CI) 99.6 (95.6-103.7) vs 72.4 (68.7-76.2) ms; pNN50 (CI) 24.2 (22.2-26.3) vs 14.4 (12.7-16.3) %; RMSSD (CI) 71.8 (67.6-76.2) vs 50.8 (46.9-54.8) ms; p HRV values than controls, but no significant differences were found between elite athletes and masters athletes. Some parameters were higher in canoeists-kayakers and bicyclists than runners. Lower cut-off values in elite athletes were SDNN: 147.4 ms, SDNN Index: 66.6 ms, pNN50: 9.7 %, RMSSD: 37.9 ms. Autonomic regulation in elite athletes described with HRV is significantly different than in healthy controls. Sports modality and level of performance, but not age- or sex-influenced HRV. Our study provides athletic normal HRV values. Further investigations are needed to determine its role in risk stratification, optimization of training, or identifying overtraining.

  12. A bioprosthetic total artificial heart for end-stage heart failure: Results from a pilot study.

    Science.gov (United States)

    Latrémouille, Christian; Carpentier, Alain; Leprince, Pascal; Roussel, Jean-Christian; Cholley, Bernard; Boissier, Elodie; Epailly, Eric; Capel, Antoine; Jansen, Piet; Smadja, David M

    2018-01-01

    The electro-hydraulically actuated Carmat total artificial heart (C-TAH) is designed to replace the heart in patients with end-stage heart failure, either as bridge to transplant or destination therapy. It provides pulsatile flow and contains bio-prosthetic blood contacting materials. A clinical feasibility study was conducted to evaluate the C-TAH safety and performance. Hospitalized patients, at imminent risk of death from irreversible biventricular failure despite optimal medical management, and not eligible for transplant or eligible but on extracorporeal life support, were enrolled. The primary endpoint was 30-days survival. Four patients were implanted with the C-TAH, three as destination therapy (ages 76, 68, 74) and one as bridge to transplant (age 58). They had implant times of 74, 270, 254 and 20 days respectively. All patients were free from hemolysis, clinical neurologic events, clinical evidence of thrombus and device-related infections. Hemodynamic and physical recovery allowed two patients to be discharged home for a cumulative duration of 7 months. The anticoagulation management strategy comprised initial unfractionated heparin, from postoperative day 2, followed by low molecular weight heparin and aspirin. An increased D-dimer level was observed in all patients during months 1 to 4. Temporary suspension of heparin anticoagulation resulted in thrombocytopenia and increased fibrin monomer, reversed by resuming anticoagulation with heparin. Causes of death were device-related (2 cases), respiratory failure and multi-organ failure. Preliminary clinical results with the C-TAH demonstrated good safety and performance profiles in patients suffering from biventricular failure, which need to be confirmed in a pivotal study. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  13. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    Directory of Open Access Journals (Sweden)

    Thomas Penzel

    2016-10-01

    Full Text Available The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG and cardio-respiratory couplings in a chronological (historical sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave.

  14. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography.

    Science.gov (United States)

    Penzel, Thomas; Kantelhardt, Jan W; Bartsch, Ronny P; Riedl, Maik; Kraemer, Jan F; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).

  15. Predictive value of casual ECG-based resting heart rate compared with resting heart rate obtained from Holter recording

    DEFF Research Database (Denmark)

    Carlson, Nicholas; Dixen, Ulrik; Marott, Jacob L

    2014-01-01

    BACKGROUND: Elevated resting heart rate (RHR) is associated with cardiovascular mortality and morbidity. Assessment of heart rate (HR) from Holter recording may afford a more precise estimate of the effect of RHR on cardiovascular risk, as compared to casual RHR. Comparative analysis was carried ...

  16. Heart rate and heart rate variability modification in chronic insomnia patients.

    Science.gov (United States)

    Farina, Benedetto; Dittoni, Serena; Colicchio, Salvatore; Testani, Elisa; Losurdo, Anna; Gnoni, Valentina; Di Blasi, Chiara; Brunetti, Riccardo; Contardi, Anna; Mazza, Salvatore; Della Marca, Giacomo

    2014-01-01

    Chronic insomnia is highly prevalent in the general population, provoking personal distress and increased risk for psychiatric and medical disorders. Autonomic hyper-arousal could be a pathogenic mechanism of chronic primary insomnia. The aim of this study was to investigate autonomic activity in patients with chronic primary insomnia by means of heart rate variability (HRV) analysis. Eighty-five consecutive patients affected by chronic primary insomnia were enrolled (38 men and 47 women; mean age: 53.2 ± 13.6). Patients were compared with a control group composed of 55 healthy participants matched for age and gender (23 men and 32 women; mean age: 54.2 ± 13.9). Patients underwent an insomnia study protocol that included subjective sleep evaluation, psychometric measures, and home-based polysomnography with evaluation of HRV in wake before sleep, in all sleep stages, and in wake after final awakening. Patients showed modifications of heart rate and HRV parameters, consistent with increased sympathetic activity, while awake before sleep and during Stage-2 non-REM sleep. No significant differences between insomniacs and controls could be detected during slow-wave sleep, REM sleep, and post-sleep wake. These results are consistent with the hypothesis that autonomic hyper-arousal is a major pathogenic mechanism in primary insomnia, and confirm that this condition is associated with an increased cardiovascular risk.

  17. Learning by Heart: Students Use Heart Rate Patterns To Identify Nervous System Imbalances.

    Science.gov (United States)

    Ackerly, Spafford C.

    2001-01-01

    Introduces a science unit on heart rate variability (HVR) patterns. Uses spectral analysis to determine the effects of environmental stimulants such as music and emotional stress on heart rate. Observes relaxation techniques and their effects on the autonomous nervous system. (Contains 12 references.) (YDS)

  18. The Syncardia™ total artificial heart: in vivo, in vitro, and computational modeling studies

    Science.gov (United States)

    Slepian, Marvin J.; Alemu, Yared; Soares, João Silva; Smith, Richard G.; Einav, Shmuel; Bluestein, Danny

    2014-01-01

    The SynCardia™ total artificial heart (TAH) is the only FDA-approved TAH in the world. The SynCardia™ TAH is a pneumatically driven, pulsatile system capable of flows of >9 L/min. The TAH is indicated for use as a bridge to transplantation (BTT) in patients at imminent risk of death from non-reversible bi-ventricular failure. In the Pivotal US approval trial the TAH achieved a BTT rate of >79%. Recently a multi-center, post-market approval study similarly demonstrated a comparable BTT rate. A major milestone was recently achieved for the TAH, with over 1100 TAHs having been implanted to date, with the bulk of implantation occurring at an ever increasing rate in the past few years. The TAH is most commonly utilized to save the lives of patients dying from end-stage bi-ventricular heart failure associated with ischemic or non-ischemic dilated cardiomyopathy. Beyond progressive chronic heart failure, the TAH has demonstrated great efficacy in supporting patients with acute irreversible heart failure associated with massive acute myocardial infarction. In recent years several diverse clinical scenarios have also proven to be well served by the TAH including severe heart failure associated with advanced congenital heart disease. failed or burned-out transplants, infiltrative and restrictive cardiomyopathies and failed ventricular assist devices. Looking to the future a major unmet need remains in providing total heart support for children and small adults. As such, the present TAH design must be scaled to fit the smaller patient, while providing equivalent, if not superior flow characteristics, shear profiles and overall device thrombogenicity. To aid in the development of a new “pediatric,” TAH an engineering methodology known as “Device Thrombogenicity Emulation (DTE)”, that we have recently developed and described, is being employed. Recently, to further our engineering understanding of the TAH, as steps towards next generation designs we have: (1

  19. The effect of metaprolol alone and metaprolol plus bromazepam on heart rate and heart rate variability during multislice computed tomography angiography

    International Nuclear Information System (INIS)

    Tuyyab, F.; Naeem, M.Y.; Maken, G.R.; Najfi, M.H.; Hassan, F.

    2012-01-01

    Objective: The purpose of this study was to determine the effect of metaprolol alone and metaprolol plus bromazepam on heart rate and heart rate variability during multi slice computed tomography (MSCT) angiography. Methodology: This was a Double blind randomized controlled trial was conducted at AFIC/NIHD, Rawalpindi, from May 2011 to November 2011. Patients undergoing first MSCT angiography meeting inclusion criteria with heart rates (HR) more than 80 beats/min were included. Patients were randomized in to two groups using random numbers table. Group 1 was administered metaprolol plus placebo while group 2 was administered metaprolol plus bromazepam one hour before the scan. Both groups had scans under strictly similar conditions. HR before and during scan along with heart rate variability (HRV) were recorded. Results: A total of 80 patients were included. Patients mean age was 49 + 13, 57 % were males while 43 % were females. Risk factor profile was similar in both groups. HR reduction in group 1 was 15+ 6.0 and in group 2, was 21+9.0 (p= 0.002). HRV in group 1 was 3.9 + 1.32 and in group 2 was 2.3 + 1.0 (p= 0.003). Group 2 had significantly lower HR and significantly less HRV as compared with group 1. Conclusion: Combination of bromazepam and metaprolol results in significant and further reduction in heart rate and heart rate variability than metaprolol alone. Both drugs can be used together for a better control of heart rate and heart rate variability during MSCT angiography for improving the quality of images. (author)

  20. "Heart rate-dependent" electrocardiographic diagnosis of left ventricular hypertrophy.

    Science.gov (United States)

    Madias, John E

    2013-05-01

    A case is presented revealing the common phenomenon of heart rate-dependent diagnosis of electrocardiographic (ECG) diagnosis of left ventricular hypertrophy (LVH), which consists of satisfaction of LVH criteria only at faster rates whereas ECGs with a slow heart rate do not satisfy such criteria. The mechanism of the phenomenon has been attributed to the tachycardia-mediated underfilling of the left ventricle bringing the electrical "centroid" of the heart closer to the recording electrodes, which results in augmentation of the amplitude of QRS complexes, particularly in leads V2-V4. ©2012, The Author. Journal compilation ©2012 Wiley Periodicals, Inc.

  1. Heating and cooling rates and their effects upon heart rate in the ...

    African Journals Online (AJOL)

    The heating and cooling rates of adult Chersina angulata were investigated to ascertain whether these tortoises can physiologically alter their rates of heat exchange. In addition, heart rates were recorded to provide an insight into the control of heat exchange. C. angulata heats significantly faster than it cools. Heart rates ...

  2. Heart rate, heart rate variability, and arrhythmias in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Falk, Bo Torkel; Zois, Nora Elisabeth

    2012-01-01

    Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD).......Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD)....

  3. Effect of oxygen treatment on heart rate after abdominal surgery

    DEFF Research Database (Denmark)

    Rosenberg-Adamsen, S; Lie, C; Bernhard, A

    1999-01-01

    BACKGROUND: Cardiac complications are common during the postoperative period and may be associated with hypoxemia and tachycardia. Preliminary studies in high-risk patients after operation have shown a possible beneficial effect of oxygen therapy on arterial oxygen saturation and heart rate....... METHODS: The authors studied the effect of oxygen therapy on arterial oxygen saturation and heart rate in 100 consecutive unselected patients randomly and double blindly allocated to receive air or oxygen therapy between the first and fourth day after major abdominal surgery. RESULTS: The median arterial...... oxygen saturation rate increased significantly from 96% to 99% (P heart rate decreased significantly from 85 beats/min to 81 beats/min (P heart rate occurred...

  4. ARTiiFACT: a tool for heart rate artifact processing and heart rate variability analysis.

    Science.gov (United States)

    Kaufmann, Tobias; Sütterlin, Stefan; Schulz, Stefan M; Vögele, Claus

    2011-12-01

    The importance of appropriate handling of artifacts in interbeat interval (IBI) data must not be underestimated. Even a single artifact may cause unreliable heart rate variability (HRV) results. Thus, a robust artifact detection algorithm and the option for manual intervention by the researcher form key components for confident HRV analysis. Here, we present ARTiiFACT, a software tool for processing electrocardiogram and IBI data. Both automated and manual artifact detection and correction are available in a graphical user interface. In addition, ARTiiFACT includes time- and frequency-based HRV analyses and descriptive statistics, thus offering the basic tools for HRV analysis. Notably, all program steps can be executed separately and allow for data export, thus offering high flexibility and interoperability with a whole range of applications.

  5. Animal studies with the Carmat bioprosthetic total artificial heart.

    Science.gov (United States)

    Latrémouille, Christian; Duveau, Daniel; Cholley, Bernard; Zilberstein, Luca; Belbis, Guillaume; Boughenou, Marie-Fazia; Meleard, Denis; Bruneval, Patrick; Adam, Clovis; Neuschwander, Arthur; Perles, Jean-Christophe; Jansen, Piet; Carpentier, Alain

    2015-05-01

    The Carmat bioprosthetic total artificial heart (TAH) contains bioprosthetic blood-contacting surfaces, and is designed for orthotopic cardiac replacement. In preparation for clinical studies, we evaluated the TAH performance and its effects on end-organ function in an animal model. Twelve female Charolais calves, 2-3 months of age and weighing 102-122 kg, were implanted with the TAH through a mid-sternotomy to ensure an adequate anatomic fit. The intended support duration was 4-10 days. Haematological values, creatinine, bilirubin and lactate levels were measured and mean arterial and central venous pressure, central venous oxygen saturation and TAH parameters were monitored. The calves were placed in a cage immediately postoperatively, and extubated on postoperative day 1 in most cases. Average support duration was 3 days, with 4 of 12 calves supported for 4, 4, 8 and 10 days. The initial procedures were used to refine surgical techniques and postoperative care. Pump output ranged from 7.3 to 10 l/min. Haemodynamic parameters and blood analysis were within acceptable ranges. No device failures occurred. No anticoagulation was used in the postoperative phase. The calves were euthanized in case of discomfort compromising the animal well-being, such as respiratory dysfunction, severe blood loss and cerebral dysfunction. Device explant analysis showed no thrombus formation inside the blood cavities. Histological examination of kidneys showed isolated micro-infarction in 2/12 animals; brain histology revealed no thromboembolic depositions. The Carmat bioprosthetic TAH implanted in calves up to 10 days provided adequate blood flow to organs and tissues. Low levels of haemolysis and no visible evidence of thromboembolic depositions in major organs and device cavities, without the use of anticoagulation, may indicate early-phase haemocompatibility of the TAH. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio

  6. Guided imagery, anxiety, heart rate, and heart rate variability during centrifuge training.

    Science.gov (United States)

    Jing, Xiaolu; Wu, Ping; Liu, Fang; Wu, Bin; Miao, Danmin

    2011-02-01

    Centrifuge training is an important method of improving the hypergravity tolerance of pilots, cosmonauts, and Chinese astronauts. However, the concomitants of tension or anxiety often impede training. Guided imagery (GI), a mind-body relaxation technique, provides a behavioral and cognitive means whereby individuals are able to exert control over the focus of attention. This study aims to investigate the immediate effects of GI for reducing stress in centrifuge training. There were 12 healthy young men who were randomly assigned to a GI group or music group. We measured changes in heart rate during centrifuge training, in heart rate variability before and after centrifuge training, and also evaluated relaxation and anxiety in three phases: before intervention, after intervention, and following centrifuge training. The change in the pattern of anxiety was different in the two groups over the three phases. Anxiety (measured by State Anxiety Inventory) in the GI group changed from 31.7 +/- 5.9 to 26.8 +/- 2.6 and 27.8 +/- 4.1, whereas for the music group this changed from 32.2 +/- 7.6 to 31.2 +/- 8.3 and 26.8 +/- 6.8. During centrifuge training, the maximal HR for the GI group (101.2 +/- 8.8) was lower than that of the music group (123.0 +/- 19.1). In addition GI showed a decrease in low frequency (LF, 0.04-0.15 Hz) components and an increase in high frequency (HF, 0.15-0.4 Hz) components before and after centrifuge training. GI was capable of decreasing tension, anxiety, and sympathetic nervous system activity pre- or post-centrifugation.

  7. Heart rate variability and heart rate turbulence in patients with polycystic ovary syndrome.

    Science.gov (United States)

    Özkeçeci, Gülay; Ünlü, Bekir Serdar; Dursun, Hüseyin; Akçi, Önder; Köken, Gülengül; Onrat, Ersel; Avşar, Alaettin

    2016-05-01

    Cardiac autonomic dysfunction may develop in patients with polycystic ovary syndrome (PCOS). Heart rate variability (HRV) and heart rate turbulence (HRT) are used in assessing cardiac autonomic functions. The goal of this study was to compare the cardiac autonomic functions in patients with PCOS and healthy controls. To our knowledge, this is the first study evaluating cardiac autonomic functions in patients with PCOS with respect to both HRV and HRT. Twenty-three patients with PCOS (mean age 22.8±3.9 years) and 25 healthy female volunteers who were matched for age and body mass index (BMI) (mean age 23.5±6.2 years) were enrolled in this as case-control study. Twenty-four hour ambulatory electrocardiogram recordings of all participants were taken using Pathfinder software. The time domain parameters of HRV and HRT, including turbulence onset (TO) and turbulence slope, were calculated. Diagnosis of PCOS was made with physical and laboratory findings of hirsutism or biochemical hyperandrogenism and chronic anovulation. Diabetes mellitus, other hormon disorders or hormon therapy, pregnancy, atrial fibrilation, obesite, chronic diseases, disorders of the autonomic nervous system, a history of drug use affecting the autonomic nervous system were excluded. There were no significant differences in HRV and HRT parameters between the two groups. Cardiovascular risk factors, such as BMI, blood pressure, fasting blood glucose, and lipid parameters, were also similar. Triangular index measure of HRV was negatively correlated with high density lipoprotein cholesterol levels (r=-0.47, p<0.05), while age and BMI were significantly correlated with TO (r=0.31 and 0.47, respectively; p<0.05 for all). Cardiac autonomic functions were not found to be altered in patients with PCOS in comparison with healthy controls. These results may be explained with the absence of concomitant cardiovascular risk factors with the patients being in the early stage of the disease.

  8. Behaviour, heart rate, and heart rate variability in pigs exposed to novelty

    Directory of Open Access Journals (Sweden)

    Manja Zupan

    2016-03-01

    Full Text Available ABSTRACT In the present study, we investigated behavioural responses and determined parameters of heart rate variability (HRV to elucidate a relative activation of autonomic nervous system (ANS during baseline (10 min and in response to potentially stressful situations (10 min in two pig breeds and sexes. Gilts (n = 21 and barrows (n = 9 of the Landrace × Yorkshire (LY; n = 15 and Landrace/Yorkshire × Landrace/Duroc (LYLD; n = 15 breeds were subjected to a novel object test (NOT and a novel arena test (NAT. Basal ANS state differed in pigs across breeds but not sexes. Landrace × Yorkshire pigs had a significantly lower basal heart rate (HR and low-frequency band (LF with a higher root mean square of successive interbeat intervals (RMSSD and high-frequency band (HF than LYLD pigs. In the NOT, despite having similar cardiac responses, gilts had a longer duration of contact with a novel object, higher lying and standing duration, and a lower duration of walking compared with barrows. In the NAT, we found similar behaviour across sexes but a different degree of ANS state, with barrows having a significantly higher increase in LF/HF (power of the low frequency component divided by the power of the high-frequency band compared with gilts. Landrace/Yorkshire × Landrace/Duroc pigs showed longer duration of contact with a novel object in the NOT accompanied by less lying and standing than LY pigs in both tests. No difference in ANS activation between breeds was found in the NOT. In the NAT, HR increased more from baseline to testing in LY pigs than in LYLD pigs. There is a complex and often contradictory nature of relationships between behaviour and cardiac responses to novelty in pigs of different breeds and sexes.

  9. Assessment of the interface of beating heart with total artificial heart using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Komoda, Tsuyoshi; Maeta, Hajime; Uyama, Chikao; Sanou, Kazuo.

    1992-01-01

    We have studied three-dimensionally (3-D) reconstructed images of atrioventricular (AV) annuli based on four-chamber magnetic resonance (MR) images for total artificial heart (TAH) implantation. To assess the interrelationship among the AV annuli and the thorax, we applied the frame of reference of the vertebral canal to these images. The Z-axis was along the vertebral canal, the Y-axis in the anteroposterior direction. The angle alpha was defined as the angle between the X-axis and the intersection between the plane of the annulus and the X-Y plane. The angle beta was defined as the angle between the Z-axis and the intersection between the plane of annulus and X-Z plane. The angle gamma was defined as the angle between the plane of the annulus and the anterior thoracic wall. We determined each angle for the mitral annulus (MVA) and tricuspid annulus (TVA) in four normal subjects to be as follows: alpha-MVA, 20.5-39.5 degrees; alpha-TVA, 26.1-43.5 degrees; beta-MVA, 4.7-49.4 degrees; beta-TVA, 4.4-40.9 degrees; and gamma-TVA, 35.2-44.1 degrees. It is suggested that reconstruction of the thoracic wall and AV annuli using the frame of reference of the diaphragmatic surface of the heart would facilitate evaluation of the spacial requirements for TAH implantation. Research to define this new frame of reference is in progress. (author)

  10. Heart rate responses induced by acoustic tempo and its interaction with basal heart rate.

    Science.gov (United States)

    Watanabe, Ken; Ooishi, Yuuki; Kashino, Makio

    2017-03-07

    Many studies have revealed the influences of music on the autonomic nervous system (ANS). Since previous studies focused on the effects of acoustic tempo on the ANS, and humans have their own physiological oscillations such as the heart rate (HR), the effects of acoustic tempo might depend on the HR. Here we show the relationship between HR elevation induced by acoustic tempo and individual basal HR. Since high tempo-induced HR elevation requires fast respiration, which is based on sympatho-respiratory coupling, we controlled the participants' respiration at a faster rate (20 CPM) than usual (15 CPM). We found that sound stimuli with a faster tempo than the individual basal HR increased the HR. However, the HR increased following a gradual increase in the acoustic tempo only when the extent of the gradual increase in tempo was within a specific range (around + 2%/min). The HR did not follow the increase in acoustic tempo when the rate of the increase in the acoustic tempo exceeded 3% per minute. These results suggest that the effect of the sympatho-respiratory coupling underlying the HR elevation caused by a high acoustic tempo depends on the basal HR, and the strength and the temporal dynamics of the tempo.

  11. Total artificial heart in the pediatric patient with biventricular heart failure.

    Science.gov (United States)

    Park, S S; Sanders, D B; Smith, B P; Ryan, J; Plasencia, J; Osborn, M B; Wellnitz, C M; Southard, R N; Pierce, C N; Arabia, F A; Lane, J; Frakes, D; Velez, D A; Pophal, S G; Nigro, J J

    2014-01-01

    Mechanical circulatory support emerged for the pediatric population in the late 1980s as a bridge to cardiac transplantation. The Total Artificial Heart (TAH-t) (SynCardia Systems Inc., Tuscon, AZ) has been approved for compassionate use by the Food and Drug Administration for patients with end-stage biventricular heart failure as a bridge to heart transplantation since 1985 and has had FDA approval since 2004. However, of the 1,061 patients placed on the TAH-t, only 21 (2%) were under the age 18. SynCardia Systems, Inc. recommends a minimum patient body surface area (BSA) of 1.7 m(2), thus, limiting pediatric application of this device. This unique case report shares this pediatric institution's first experience with the TAH-t. A 14-year-old male was admitted with dilated cardiomyopathy and severe biventricular heart failure. The patient rapidly decompensated, requiring extracorporeal life support. An echocardiogram revealed severe biventricular dysfunction and diffuse clot formation in the left ventricle and outflow tract. The decision was made to transition to biventricular assist device. The biventricular failure and clot formation helped guide the team to the TAH-t, in spite of a BSA (1.5 m(2)) below the recommendation of 1.7 m(2). A computed tomography (CT) scan of the thorax, in conjunction with a novel three-dimensional (3D) modeling system and team, assisted in determining appropriate fit. Chest CT and 3D modeling following implantation were utilized to determine all major vascular structures were unobstructed and the bronchi were open. The virtual 3D model confirmed appropriate device fit with no evidence of compression to the left pulmonary veins. The postoperative course was complicated by a left lung opacification. The left lung anomalies proved to be atelectasis and improved with aggressive recruitment maneuvers. The patient was supported for 11 days prior to transplantation. Chest CT and 3D modeling were crucial in assessing whether the device would

  12. The fall in the rate of death from heart diseases

    International Nuclear Information System (INIS)

    Bemski, G.

    1983-01-01

    A self limiting interaction between heart disease producing factors and genetic factors is postulated. Such an interaction could be responsable for the fall in rate of death from ischemic disease observed in the United States. (Author) [pt

  13. Effect of atrioventricular conduction on heart rate variability

    KAUST Repository

    Ahmad, Talha Jamal; Ali, Hussnain; Majeed, S. M Imran; Khan, Shoab A.

    2011-01-01

    This paper discusses the effect of atrioventricular conduction time (AVCT) on the short-term Heart Rate Variability (HRV) by computing HRV parameters using intervals between the onsets of successive P waves (PP time series) for three groups: normal

  14. Arduino-based noise robust online heart-rate detection.

    Science.gov (United States)

    Das, Sangita; Pal, Saurabh; Mitra, Madhuchhanda

    2017-04-01

    This paper introduces a noise robust real time heart rate detection system from electrocardiogram (ECG) data. An online data acquisition system is developed to collect ECG signals from human subjects. Heart rate is detected using window-based autocorrelation peak localisation technique. A low-cost Arduino UNO board is used to implement the complete automated process. The performance of the system is compared with PC-based heart rate detection technique. Accuracy of the system is validated through simulated noisy ECG data with various levels of signal to noise ratio (SNR). The mean percentage error of detected heart rate is found to be 0.72% for the noisy database with five different noise levels.

  15. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  16. Effects of Interval Training Programme on Resting Heart Rate in ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    Subjects with Hypertension: A Randomized Controlled Trial. Type of Article: Original ... Resting Heart Rate in Subjects with Hypertension — Lamina S. et al investigate the effect of interval .... changes in VO max) of interest. In the t-test. 2.

  17. Accuracy of Heart Rate Watches: Implications for Weight Management.

    Directory of Open Access Journals (Sweden)

    Matthew P Wallen

    Full Text Available Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established.To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha to measure heart rate and energy expenditure at rest and during exercise.Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate and indirect calorimetry (energy expenditure.None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98] and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]. All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9% but greater for energy expenditure (9-43%. Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm than energy expenditure (ranging from -266.7 to 65.7 kcals across devices.These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  18. Accuracy of Heart Rate Watches: Implications for Weight Management.

    Science.gov (United States)

    Wallen, Matthew P; Gomersall, Sjaan R; Keating, Shelley E; Wisløff, Ulrik; Coombes, Jeff S

    2016-01-01

    Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9%) but greater for energy expenditure (9-43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  19. Heart rate and activity profile for young female soccer players

    OpenAIRE

    Barbero Álvarez, José Carlos; Gómez López, Maite; Barbero Álvarez, Verónica; Granda Vera, Juan; Castagna, Carlo

    2008-01-01

    The physical and physiological demands of high-level male soccer have been studied extensively, while few studies have investigated the demands placed on females during match-play, however, there is no information available about the heart rate and activity profile of young female soccer players during match play. Therefore, the aim of this study was to examine cardiovascular (heart-rates HR) and physical demands of young female soccer players during a match. Players were observed during a fr...

  20. Value of Serial Heart Rate Variability Measurement for Prediction of Appropriate ICD Discharge in Patients with Heart Failure

    NARCIS (Netherlands)

    ten Sande, Judith N.; Damman, Peter; Tijssen, Jan G. P.; de Groot, Joris R.; Knops, Reinoud E.; Wilde, Arthur A. M.; van Dessel, Pascal F. H. M.

    2014-01-01

    HRV and Appropriate ICD Shock in Heart Failure Introduction Decreased heart rate variability (HRV) is associated with adverse outcomes in patients with heart failure. Our objective was to examine whether decreased HRV predicts appropriate implantable cardioverter defibrillator (ICD) shocks. Methods

  1. Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring.

    Science.gov (United States)

    Lin, Zhiming; Chen, Jun; Li, Xiaoshi; Zhou, Zhihao; Meng, Keyu; Wei, Wei; Yang, Jin; Wang, Zhong Lin

    2017-09-26

    Heart-rate monitoring plays a critical role in personal healthcare management. A low-cost, noninvasive, and user-friendly heart-rate monitoring system is highly desirable. Here, a self-powered wireless body sensor network (BSN) system is developed for heart-rate monitoring via integration of a downy-structure-based triboelectric nanogenerator (D-TENG), a power management circuit, a heart-rate sensor, a signal processing unit, and Bluetooth module for wireless data transmission. By converting the inertia energy of human walking into electric power, a maximum power of 2.28 mW with total conversion efficiency of 57.9% was delivered at low operation frequency, which is capable of immediately and sustainably driving the highly integrated BSN system. The acquired heart-rate signal by the sensor would be processed in the signal process circuit, sent to an external device via the Bluetooth module, and displayed on a personal cell phone in a real-time manner. Moreover, by combining a TENG-based generator and a TENG-based sensor, an all-TENG-based wireless BSN system was developed, realizing continuous and self-powered heart-rate monitoring. This work presents a potential method for personal heart-rate monitoring, featured as being self-powered, cost-effective, noninvasive, and user-friendly.

  2. Increased heart rate variability but normal resting metabolic rate in hypocretin/orexin-deficient human narcolepsy.

    NARCIS (Netherlands)

    Fronczek, R.; Overeem, S.; Reijntjes, R.; Lammers, G.J.; Dijk, J.G.M.; Pijl, H.

    2008-01-01

    STUDY OBJECTIVES: We investigated autonomic balance and resting metabolic rate to explore their possible involvement in obesity in hypocretin/orexin-deficient narcoleptic subjects. METHODS: Resting metabolic rate (using indirect calorimetry) and variability in heart rate and blood pressure were

  3. Probability of detection of clinical seizures using heart rate changes.

    Science.gov (United States)

    Osorio, Ivan; Manly, B F J

    2015-08-01

    Heart rate-based seizure detection is a viable complement or alternative to ECoG/EEG. This study investigates the role of various biological factors on the probability of clinical seizure detection using heart rate. Regression models were applied to 266 clinical seizures recorded from 72 subjects to investigate if factors such as age, gender, years with epilepsy, etiology, seizure site origin, seizure class, and data collection centers, among others, shape the probability of EKG-based seizure detection. Clinical seizure detection probability based on heart rate changes, is significantly (pprobability of detecting clinical seizures (>0.8 in the majority of subjects) using heart rate is highest for complex partial seizures, increases with a patient's years with epilepsy, is lower for females than for males and is unrelated to the side of hemisphere origin. Clinical seizure detection probability using heart rate is multi-factorially dependent and sufficiently high (>0.8) in most cases to be clinically useful. Knowledge of the role that these factors play in shaping said probability will enhance its applicability and usefulness. Heart rate is a reliable and practical signal for extra-cerebral detection of clinical seizures originating from or spreading to central autonomic network structures. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  4. Power spectral analysis of heart rate in hyperthyroidism.

    Science.gov (United States)

    Cacciatori, V; Bellavere, F; Pezzarossa, A; Dellera, A; Gemma, M L; Thomaseth, K; Castello, R; Moghetti, P; Muggeo, M

    1996-08-01

    The aim of the present study was to evaluate the impact of hyperthyroidism on the cardiovascular system by separately analyzing the sympathetic and parasympathetic influences on heart rate. Heart rate variability was evaluated by autoregressive power spectral analysis. This method allows a reliable quantification of the low frequency (LF) and high frequency (HF) components of the heart rate power spectral density; these are considered to be under mainly sympathetic and pure parasympathetic control, respectively. In 10 newly diagnosed untreated hyperthyroid patients with Graves' disease, we analyzed power spectral density of heart rate cyclic variations at rest, while lying, and while standing. In addition, heart rate variations during deep breathing, lying and standing, and Valsalva's maneuver were analyzed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. In 8 hyperthyroid patients, the same evaluation was repeated after the induction of stable euthyroidism by methimazole. Heart rate power spectral analysis showed a sharp reduction of HF components in hyperthyroid subjects compared to controls [lying, 13.3 +/- 4.1 vs. 32.0 +/- 5.6 normalized units (NU; P hyperthyroid subjects while both lying (11.3 +/- 4.5 vs. 3.5 +/- 1.1; P hyperthyroid patients than in controls (1.12 +/- 0.03 vs. 1.31 +/- 0.04; P activity and, thus, a relative hypersympathetic tone.

  5. Hemodynamics of a functional centrifugal-flow total artificial heart with functional atrial contraction in goats.

    Science.gov (United States)

    Shiga, Takuya; Shiraishi, Yasuyuki; Sano, Kyosuke; Taira, Yasunori; Tsuboko, Yusuke; Yamada, Akihiro; Miura, Hidekazu; Katahira, Shintaro; Akiyama, Masatoshi; Saiki, Yoshikatsu; Yambe, Tomoyuki

    2016-03-01

    Implantation of a total artificial heart (TAH) is one of the therapeutic options for the treatment of patients with end-stage biventricular heart failure. There is no report on the hemodynamics of the functional centrifugal-flow TAH with functional atrial contraction (fCFTAH). We evaluated the effects of pulsatile flow by atrial contraction in acute animal models. The goats received fCFTAH that we created from two centrifugal-flow ventricular assist devices. Some hemodynamic parameters maintained acceptable levels: heart rate 115.5 ± 26.3 bpm, aortic pressure 83.5 ± 10.1 mmHg, left atrial pressure 18.0 ± 5.9 mmHg, pulmonary pressure 28.5 ± 9.7 mmHg, right atrial pressure 13.6 ± 5.2 mmHg, pump flow 4.0 ± 1.1 L/min (left) 3.9 ± 1.1 L/min (right), and cardiac index 2.13 ± 0.14 L/min/m(2). fCFTAH with atrial contraction was able to maintain the TAH circulation by forming a pulsatile flow in acute animal experiments. Taking the left and right flow rate balance using the low internal pressure loss of the VAD pumps may be easier than by other pumps having considerable internal pressure loss. We showed that the remnant atrial contraction effected the flow rate change of the centrifugal pump, and the atrial contraction waves reflected the heart rate. These results indicate that remnant atria had the possibility to preserve autonomic function in fCFTAH. We may control fCFTAH by reflecting the autonomic function, which is estimated with the flow rate change of the centrifugal pump.

  6. Assessing positive emotional states in dogs using heart rate and heart rate variability.

    Science.gov (United States)

    Zupan, Manja; Buskas, Julia; Altimiras, Jordi; Keeling, Linda J

    2016-03-01

    Since most animal species have been recognized as sentient beings, emotional state may be a good indicator of welfare in animals. The goal of this study was to manipulate the environment of nine beagle research dogs to highlight physiological responses indicative of different emotional experiences. Stimuli were selected to be a more or a less positive food (meatball or food pellet) or social reward (familiar person or less familiar person). That all the stimuli were positive and of different reward value was confirmed in a runway motivation test. Dogs were tested individually while standing facing a display theatre where the different stimuli could be shown by lifting a shutter. The dogs approached and remained voluntarily in the test system. They were tested in four sessions (of 20s each) for each of the four stimuli. A test session consisted of four presentation phases (1st exposure to stimulus, post exposure, 2nd exposure, and access to reward). Heart rate (HR) and heart rate variability (HRV) responses were recorded during testing in the experimental room and also when lying resting in a quiet familiar room. A new method of 'stitching' short periods of HRV data together was used in the analysis. When testing different stimuli, no significant differences were observed in HR and LF:HF ratio (relative power in low frequency (LF) and the high-frequency (HF) range), implying that the sympathetic tone was activated similarly for all the stimuli and may suggest that dogs were in a state of positive arousal. A decrease of HF was associated with the meatball stimulus compared to the food pellet and the reward phase (interacting with the person or eating the food) was associated with a decrease in HF and RMSSD (root mean square of successive differences of inter-beat intervals) compared to the preceding phase (looking at the person or food). This suggests that parasympathetic deactivation is associated with a more positive emotional state in the dog. A similar reduction

  7. Total Artificial Heart and Chronic Haemodialysis: A Possible Bridge to Transplantation?

    Science.gov (United States)

    Demiselle, Julien; Besson, Virginie; Sayegh, Johnny; Subra, Jean-François; Augusto, Jean-François

    2016-01-01

    Total artificial heart (TAH) device is sometimes necessary to treat end stage heart failure (HF). After surgery, renal impairment can occur with the need of renal replacement therapy. We report the case of a 51-year-old man who was treated with conventional hemodialysis (HD) while on support with TAH. The patient underwent HD while on TAH support during 14 months. He benefited from conventional HD, 6 sessions per week. HD sessions were well tolerated, and patient's condition and quality of life improved significantly. The main difficulty was to maintain red blood cell level because of chronic hemolysis due to TAH, which required repetitive blood transfusions, resulting in a high rate of human leukocyte antigen sensitization. Unfortunately, the patient died of mesenteric ischemia due to anticoagulation under dosing. We conclude that HD treatment is possible despite TAH and should be considered in patients with both end stage renal and HF. © 2016 S. Karger AG, Basel.

  8. The heart field effect: Synchronization of healer-subject heart rates in energy therapy.

    Science.gov (United States)

    Bair, Christine Caldwell

    2008-01-01

    Recent health research has focused on subtle energy and vibrational frequency as key components of health and healing. In particular, intentional direction of bioenergy is receiving increasing scientific attention. This study investigates the effect of the healer's electromagnetic (EM) heart field upon subjects during energy healing as measured by synchronization of heart rates and scores on a Subjective Units of Distress (SUD) scale and a Profile of Mood States (POMS) inventory. A nonequivalent pretest-posttest design was used based on heart rate comparisons between healer and subject and correlated with pre-and posttest SUD and POMS scores. Subjects included those who sat within the 3- to 4-foot "strong" range of the independent variable, the healer's heart field, while performing self-application of WHEE (the wholistic hybrid derived from EMDR [eye movement desensitization and reprocessing], and EFT [emotional freedom technique]), a meridian-based tapping technique (n=50); and those who performed the same process beyond the 15- to 18-foot range of the healer's EM heart field (n=41). The dependent variables were heart rate, SUD, and POMS inventory. All subjects completed these measures within 1 hour. Study results showed statistically significant heart-rate synchronization with the intervention population. In addition, SUD and POMS scores demonstrated considerably more improvement than in the control population, indicating additional benefit beyond the meridian-based therapies, such as WHEE, alone. Additional findings and future research recommendations are presented in this article.

  9. Entropies, Partitionings and Heart Rate Variability

    Czech Academy of Sciences Publication Activity Database

    Paluš, Milan; Zebrowski, J.

    2009-01-01

    Roč. 51, č. 2 (2009), s. 65-72 ISSN 0001-7604 Institutional research plan: CEZ:AV0Z10300504 Keywords : coarse-grained entropy rate * HR variability * entropy Subject RIV: BB - Applied Statistics, Operational Research http://www.activitas.org/index.php/nervosa/article/view/25

  10. Unconstrained monitoring of long-term heart and breath rates during sleep

    International Nuclear Information System (INIS)

    Chen, Wenxi; Zhu, Xin; Wei, Daming; Nemoto, Tetsu; Sugitani, Kayo; Kitamura, Kei-ichiro

    2008-01-01

    An unconstrained method for the long-term monitoring of heart and breath rates during sleep is proposed. The system includes a sensor unit and a web-based network module. The sensor unit is set beneath a pillow to pick up the pressure variations from the head induced by inhalation/exhalation movements and heart pulsation during sleep. The measured pressure signal was digitized and transferred to a remote database server via the network module. A wavelet-based algorithm was employed to detect the heart and breath rates, as well as body movement, during sleep. The overall system was utilized for a total six-month trial operation delivered to a female subject. The profiles of the heart and breath rates on a beat-by-beat and daily basis were obtained. Movements during sleep were also estimated. The results show that the daily average percentage of undetectable periods (UPs) during 881.6 sleep hours over a 180 day period was 17.2%. A total of 89.2% of sleep hours had a UP of not more than 25%. The profile of the heart rate revealed a periodic property that corresponded to the female monthly menstrual cycle. Our system shows promise as a long-term unconstrained monitor for heart and breath rates, and for other physiological parameters related to the quality of sleep and the regularity of the menstrual cycle. (note)

  11. Quantification of fetal heart rate regularity using symbolic dynamics

    Science.gov (United States)

    van Leeuwen, P.; Cysarz, D.; Lange, S.; Geue, D.; Groenemeyer, D.

    2007-03-01

    Fetal heart rate complexity was examined on the basis of RR interval time series obtained in the second and third trimester of pregnancy. In each fetal RR interval time series, short term beat-to-beat heart rate changes were coded in 8bit binary sequences. Redundancies of the 28 different binary patterns were reduced by two different procedures. The complexity of these sequences was quantified using the approximate entropy (ApEn), resulting in discrete ApEn values which were used for classifying the sequences into 17 pattern sets. Also, the sequences were grouped into 20 pattern classes with respect to identity after rotation or inversion of the binary value. There was a specific, nonuniform distribution of the sequences in the pattern sets and this differed from the distribution found in surrogate data. In the course of gestation, the number of sequences increased in seven pattern sets, decreased in four and remained unchanged in six. Sequences that occurred less often over time, both regular and irregular, were characterized by patterns reflecting frequent beat-to-beat reversals in heart rate. They were also predominant in the surrogate data, suggesting that these patterns are associated with stochastic heart beat trains. Sequences that occurred more frequently over time were relatively rare in the surrogate data. Some of these sequences had a high degree of regularity and corresponded to prolonged heart rate accelerations or decelerations which may be associated with directed fetal activity or movement or baroreflex activity. Application of the pattern classes revealed that those sequences with a high degree of irregularity correspond to heart rate patterns resulting from complex physiological activity such as fetal breathing movements. The results suggest that the development of the autonomic nervous system and the emergence of fetal behavioral states lead to increases in not only irregular but also regular heart rate patterns. Using symbolic dynamics to

  12. Modeling baroreflex regulation of heart rate during orthostatic stress

    DEFF Research Database (Denmark)

    Olufsen, Mette; Tran, Hien T.; Ottesen, Johnny T.

    2006-01-01

    . The model uses blood pressure measured in the finger as an input to model heart rate dynamics in response to changes in baroreceptor nerve firing rate, sympathetic and parasympathetic responses, vestibulo-sympathetic reflex, and concentrations of norepinephrine and acetylcholine. We formulate an inverse...... in healthy and hypertensive elderly people the hysteresis loop shifts to higher blood pressure values and its area is diminished. Finally, for hypertensive elderly people the hysteresis loop is generally not closed indicating that during postural change from sitting to standing, the blood pressure resettles......During orthostatic stress, arterial and cardiopulmonary baroreflexes play a key role in maintaining arterial pressure by regulating heart rate. This study, presents a mathematical model that can predict the dynamics of heart rate regulation in response to postural change from sitting to standing...

  13. Heart rate measurement based on face video sequence

    Science.gov (United States)

    Xu, Fang; Zhou, Qin-Wu; Wu, Peng; Chen, Xing; Yang, Xiaofeng; Yan, Hong-jian

    2015-03-01

    This paper proposes a new non-contact heart rate measurement method based on photoplethysmography (PPG) theory. With this method we can measure heart rate remotely with a camera and ambient light. We collected video sequences of subjects, and detected remote PPG signals through video sequences. Remote PPG signals were analyzed with two methods, Blind Source Separation Technology (BSST) and Cross Spectral Power Technology (CSPT). BSST is a commonly used method, and CSPT is used for the first time in the study of remote PPG signals in this paper. Both of the methods can acquire heart rate, but compared with BSST, CSPT has clearer physical meaning, and the computational complexity of CSPT is lower than that of BSST. Our work shows that heart rates detected by CSPT method have good consistency with the heart rates measured by a finger clip oximeter. With good accuracy and low computational complexity, the CSPT method has a good prospect for the application in the field of home medical devices and mobile health devices.

  14. Heart rate-based lactate minimum test: a reproducible method.

    NARCIS (Netherlands)

    Strupler, M.; Muller, G.; Perret, C.

    2009-01-01

    OBJECTIVE: To find the individual intensity for aerobic endurance training, the lactate minimum test (LMT) seems to be a promising method. LMTs described in the literature consist of speed or work rate-based protocols, but for training prescription in daily practice mostly heart rate is used. The

  15. The Use of Heart Rate Monitors in Physical Education

    Science.gov (United States)

    Nichols, Randall; Davis, Kathryn L.; McCord, Tim; Schmidt, Dave; Slezak, Alex M.

    2009-01-01

    The ever-rising rate of obesity and the need for increased physical activity for young children is well documented. Data suggests that today's youth are not participating in enough quality health-enhancing physical activity either in or outside of school. Heart rate monitors have been used by adult exercisers for many years to monitor and assess…

  16. Total artificial heart implantation for biventricular failure due to eosinophilic myocarditis.

    Science.gov (United States)

    Kawabori, Masashi; Kurihara, Chitaru; Miller, Yair; Heck, Kent A; Bogaev, Roberta C; Civitello, Andrew B; Cohn, William E; Frazier, O H; Morgan, Jeffrey A

    2017-09-01

    Idiopathic hypereosinophilic syndrome is a condition of unknown etiology characterized by proliferation of eosinophils and their infiltration into tissues. Although cardiac involvement is rare, eosinophilic myocarditis can lead to life-threating fulminant congestive heart failure. Treatment of patients with eosinophilic myocarditis is challenging as heart failure can be caused by biventricular dysfunction. To our knowledge, this is the first case reported in the literature describing a patient with acute severe biventricular heart failure caused by eosinophilic myocarditis with mural left ventricular apical thrombus who was successfully treated with implantation of a total artificial heart as a bridge to heart transplant.

  17. Total Artificial Heart as Rescue Therapy for Primary Graft Failure in an Infant.

    Science.gov (United States)

    Ziegler, Luke A; Sainathan, Sandeep; Morell, Victor O; Sharma, Mahesh S

    2018-04-01

    An infant unable to be weaned from cardiopulmonary bypass after orthotopic heart transplantation was cannulated for extracorporeal membrane oxygenation. During the next 3 days, allograft failure and intracardiac thrombosis necessitated cardiectomy. To provide acute mechanical circulatory support, artificial atrial chambers were constructed with Gore-Tex conduits and PediMag centrifugal pumps were connected to each by Berlin Heart EXCOR cannulae. The PediMag pumps were subsequently exchanged for 10-mL Berlin Heart EXCOR pumps. After 60 days of support by total artificial heart, the patient was bridged successfully to a second heart transplant. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Heart Rate Monitoring in Team Sports—A Conceptual Framework for Contextualizing Heart Rate Measures for Training and Recovery Prescription

    Directory of Open Access Journals (Sweden)

    Christoph Schneider

    2018-05-01

    Full Text Available A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3–5 min submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution combined with multivariate analysis, which includes markers of (perceived wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using

  19. Heart Rate Monitoring in Team Sports-A Conceptual Framework for Contextualizing Heart Rate Measures for Training and Recovery Prescription.

    Science.gov (United States)

    Schneider, Christoph; Hanakam, Florian; Wiewelhove, Thimo; Döweling, Alexander; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander

    2018-01-01

    A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS) and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3-5 min) submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution) combined with multivariate analysis, which includes markers of (perceived) wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using simple heuristics. To

  20. Totally implantable total artificial heart and ventricular assist device with multipurpose miniature electromechanical energy system.

    Science.gov (United States)

    Takatani, S; Orime, Y; Tasai, K; Ohara, Y; Naito, K; Mizuguchi, K; Makinouchi, K; Damm, G; Glueck, J; Ling, J

    1994-01-01

    A multipurpose miniature electromechanical energy system has been developed to yield a compact, efficient, durable, and biocompatible total artificial heart (TAH) and ventricular assist device (VAD). Associated controller-driver electronics were recently miniaturized and converted into hybrid circuits. The hybrid controller consists of a microprocessor and controller, motor driver, Hall sensor, and commutation circuit hybrids. The sizing study demonstrated that all these components can be incorporated in the pumping unit of the TAH and VAD, particularly in the centerpiece of the TAH and the motor housing of the VAD. Both TAH and VAD pumping units will start when their power line is connected to either the internal power pack or the external battery unit. As a redundant driving and diagnostic port, an emergency port was newly added and will be placed in subcutaneous location. In case of system failure, the skin will be cut down, and an external motor drive or a pneumatic driver will be connected to this port to run the TAH. This will minimize the circulatory arrest time. Overall efficiency of the TAH without the transcutaneous energy transmission system was 14-18% to deliver pump outputs of 4-9 L/min against the right and left afterload pressures of 25 and 100 mm Hg. The internal power requirement ranged from 6 to 13 W. The rechargeable batteries such as NiCd or NiMH with 1 AH capacity can run the TAH for 30-45 min. The external power requirement, when TETS efficiency of 75% was assumed, ranged from 8 to 18 W. The accelerated endurance test in the 42 degrees C saline bath demonstrated stable performance over 4 months. Long-term endurance and chronic animal studies will continue toward a system with 5 years durability by the year 2000.

  1. Heart Rate Variability in Nonlinear Rats with Different Orientation and Exploratory Activity in the Open Field.

    Science.gov (United States)

    Kur'yanova, E V; Teplyi, D L; Zhukova, Yu D; Zhukovina, N V

    2015-12-01

    The basic behavioral activity of nonlinear rats was evaluated from the sum of crossed peripheral and central squares and peripheral and central rearing postures in the open fi eld test. This index was low (30 episodes). Male rats with high score of orientation and exploratory activity were characterized by higher indexes of total heart rate variability than rats with low or intermediate activity. Specimens with a greater contribution of VLF waves into the total power spectrum of heart rate variability were shown to dominate among the rats with high behavioral activity. Our results are consistent with the notions of a suprasegmental nature of VLF waves.

  2. Changes in heart rate and heart rate variability during transportation of horses by road and air.

    Science.gov (United States)

    Ohmura, Hajime; Hobo, Seiji; Hiraga, Atsushi; Jones, James H

    2012-04-01

    To determine the influence of transportation by road and air on heart rate (HR) and HR variability (HRV) in horses. Animals-6 healthy horses. ECG recordings were obtained from horses before (quarantine with stall rest [Q]; 24 hours) and during a journey that included transportation by road (RT; 4.5 hours), waiting on the ground in an air stall (W; 5.5 hours), and transportation by air (AT; 11 hours); HR was determined, and HRV indices of autonomic nervous activity (low-frequency [LF; 0.01 to 0.07 Hz] and high-frequency [HF; 0.07 to 0.6 Hz] power) were calculated. Mean ± SD HRs during Q, RT, W, and AT were 38.9 ± 1.5 beats/min, 41.7 ± 5.6 beats/min, 41.5 ± 4.3 beats/min, and 48.8 ± 5.6 beats/min, respectively; HR during AT was significantly higher than HR during Q. The LF power was significantly higher during Q (3,454 ± 1,087 milliseconds(2)) and AT (3,101 ± 567 milliseconds(2)) than it was during RT (1,824 ± 432 milliseconds(2)) and W (2,072 ± 616 milliseconds(2)). During Q, RT, W, and AT, neither HF powers (range, 509 to 927 milliseconds(2)) nor LF:HF ratios (range, 4.1 to 6.2) differed significantly. The HR during RT was highly correlated with LF power (R(2) = 0.979), and HR during AT was moderately correlated with the LF:HF ratio (R(2) = 0.477). In horses, HR and HRV indices during RT and AT differed, suggesting that exposure to different stressors results in different autonomic nervous influences on HR.

  3. Relationship between heart rate and preference for tempo of music.

    Science.gov (United States)

    Iwanaga, M

    1995-10-01

    People prefer music with tempi ranging from 70 to 100 cycles per minute similar to that of adults' heart rate within normal daily situations. Previous studies of the relation between preferred tempi and heart rates using a pure tone also have indicated that subjects tended to prefer tempi similar to their heart rates. The present study examined this relationship using a musical piece (the theme of "It's a small world") as a stimulus. 14 undergraduate women were subjects who searched for their favorite tempi by controlling the musical tempo by themselves. The most preferred tempo was close to their cycle of heart beats, however, tempi that were one and a half and twice as fast as the heart rate were less preferred in the present study than in a previous study using a tone. Subjects preferred faster tempi in the descending series of stimuli than in the ascending one, and hence were influenced by the initial value of the tempo in the trial sequence. The effects due to the differences of the meaning of the stimuli are considered.

  4. QRS peak detection for heart rate monitoring on Android smartphone

    Science.gov (United States)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  5. Social network diversity and risks of ischemic heart disease and total mortality

    DEFF Research Database (Denmark)

    Barefoot, John C; Grønbaek, Morten; Jensen, Gorm

    2005-01-01

    Measures of various types of social contacts were used as predictors of ischemic heart disease events and total mortality in an age-stratified random sample of 9,573 adults enrolled in the Copenhagen City Heart Study (Copenhagen, Denmark). Baseline examinations were conducted in 1991-1994, and pa......Measures of various types of social contacts were used as predictors of ischemic heart disease events and total mortality in an age-stratified random sample of 9,573 adults enrolled in the Copenhagen City Heart Study (Copenhagen, Denmark). Baseline examinations were conducted in 1991...

  6. Exaggerated heart rate oscillations during two meditation techniques.

    Science.gov (United States)

    Peng, C K; Mietus, J E; Liu, Y; Khalsa, G; Douglas, P S; Benson, H; Goldberger, A L

    1999-07-31

    We report extremely prominent heart rate oscillations associated with slow breathing during specific traditional forms of Chinese Chi and Kundalini Yoga meditation techniques in healthy young adults. We applied both spectral analysis and a novel analytic technique based on the Hilbert transform to quantify these heart rate dynamics. The amplitude of these oscillations during meditation was significantly greater than in the pre-meditation control state and also in three non-meditation control groups: i) elite athletes during sleep, ii) healthy young adults during metronomic breathing, and iii) healthy young adults during spontaneous nocturnal breathing. This finding, along with the marked variability of the beat-to-beat heart rate dynamics during such profound meditative states, challenges the notion of meditation as only an autonomically quiescent state.

  7. Demikhov's "Mechanical Heart": The Circumstances Surrounding Creation of the World's First Implantable Total Artificial Heart in 1937.

    Science.gov (United States)

    Glyantsev, Sergey P; Tchantchaleishvili, Vakhtang; Bockeria, Leo A

    2016-01-01

    The world's first implantable total artificial heart was designed by Vladimir Demikhov as a fourth year biology student in Voronezh, Soviet Union, in 1937. As a prototype of his device, Demikhov must have used an apparatus for extracorporeal blood circulation invented by Sergei Bryukhonenko of Moscow. The device was the size of a dog's native heart and consisted of two diaphragm pumps brought into motion by an electric motor. A dog with an implanted device lived for 2.5 hours. In addition to having the prototype, the preconditions for Demikhov's artificial heart creation were his manual dexterity, expertise in animal physiology, and his mechanistic worldview.

  8. MOUNTAIN BIKE, MONITORING AND HEART RATE MONITOR

    Directory of Open Access Journals (Sweden)

    Claudio Scotton

    2015-04-01

    Full Text Available Chi pratica sport, sia con obiettivi agonistici sia di fitness, cerca di mantenere il proprio stato di forma ad un livello che gli permetta di essere prestativo e contemporaneamente di prevenire eventi traumatici (Scotton et Al 2006; Viru, Viru 2002. L’atleta che compete, amatore o professionista, dovrebbe seguire scrupolosamente la periodizzazione (Scotton, Gollin 2006 e la programmazione più idonee ai propri scopi, privilegiando i mezzi e i metodi di allenamento più congeniali a lui e più utili per lo specifico periodo. E’ noto che quando si avvicinano le gare il tipo di allenamento seguito assomiglia sempre più alla tipologia di competizione. E’ abitudine consolidata per chi svolge una qualsiasi specialità sportiva (Scotton 2003 con finalità non agonistiche cercare di mantenere efficiente l’apparato locomotore ed i sistemi ad esso collegati (Wilmore, Costill 2005 per ottenere divertimento e, appunto, il fitness, senza considerare troppo le norme che regolano l’allenamento sportivo. Un soggetto, non professionista, indossando il cardiofrequenzimetro Polar S710i ha effettuato due sessioni di allenamento su una mountain bike da free-ride in due distinte giornate e sullo stesso percorso.Il software dello strumento consente di sovrapporre i files del medesimo giro evidenziando le somiglianze dei tratti principali delle sedute: la durata della salita e della discesa con le velocità ottenute e i km percorsi, le frequenze cardiache medie e massime relative alle singole frazioni dell’allenamento e nel totale.Obiettivo: Nel lavoro si propone di utilizzare i dati raccolti sul percorso “reale” per permettere all’atleta di replicarlo a casa o in palestra mantenendo le frequenze cardiache per il tempo indicato abbinando all’uso dei rulli, su cui è posizionata la bicicletta, anche l’impiego del cardiofrequenzimetro (Wirnitzer KC, Kornexl E 2008.

  9. Heart rate variability and baroreflex sensitivity in bilateral lung transplant recipients.

    Science.gov (United States)

    Fontolliet, Timothée; Gianella, Pietro; Pichot, Vincent; Barthélémy, Jean-Claude; Gasche-Soccal, Paola; Ferretti, Guido; Lador, Frédéric

    2018-01-09

    The effects of lung afferents denervation on cardiovascular regulation can be assessed on bilateral lung transplantation patients. The high-frequency component of heart rate variability is known to be synchronous with breathing frequency. Then, if heart beat is neurally modulated by breathing frequency, we may expect disappearance of high frequency of heart rate variability in bilateral lung transplantation patients. On 11 patients and 11 matching healthy controls, we measured R-R interval (electrocardiography), blood pressure (Portapres ® ) and breathing frequency (ultrasonic device) in supine rest, during 10-min free breathing, 10-min cadenced breathing (0·25 Hz) and 5-min handgrip. We analysed heart rate variability and spontaneous variability of arterial blood pressure, by power spectral analysis, and baroreflex sensitivity, by the sequence method. Concerning heart rate variability, with respect to controls, transplant recipients had lower total power and lower low- and high-frequency power. The low-frequency/high-frequency ratio was higher. Concerning systolic, diastolic and mean arterial pressure variability, transplant recipients had lower total power (only for cadenced breathing), low frequency and low-frequency/high-frequency ratio during free and cadenced breathing. Baroreflex sensitivity was decreased. Denervated lungs induced strong heart rate variability reduction. The higher low-frequency/high-frequency ratio suggested that the total power drop was mostly due to high frequency. These results support the hypothesis that neural modulation from lung afferents contributes to the high frequency of heart rate variability. © 2018 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  10. Heart rate variability as determinism with jump stochastic parameters.

    Science.gov (United States)

    Zheng, Jiongxuan; Skufca, Joseph D; Bollt, Erik M

    2013-08-01

    We use measured heart rate information (RR intervals) to develop a one-dimensional nonlinear map that describes short term deterministic behavior in the data. Our study suggests that there is a stochastic parameter with persistence which causes the heart rate and rhythm system to wander about a bifurcation point. We propose a modified circle map with a jump process noise term as a model which can qualitatively capture such this behavior of low dimensional transient determinism with occasional (stochastically defined) jumps from one deterministic system to another within a one parameter family of deterministic systems.

  11. Heart Rate Monitor for Portable MP3 Player.

    Science.gov (United States)

    Kim, Jaywoo; Lee, Mi-Hee; Lee, Hyoung-Ki; Choi, Kiwan; Bang, Seokwon; Kim, Sangryong

    2005-01-01

    This paper presents a photoplethysmography sensor based on a heart rate monitor for a portable MP3 player. Two major design issues are addressed: one is to acquire the sensor signal with a proper amplitude despite a wide range of variation and the other is to handle the noise contaminated signal which is caused by a motion artifact. A benchmarking test with a professional medical photoplethysmography sensor shows that our device performs very well in calculating heart rate even though our photoplethysmography sensor module was designed to be cost effective.

  12. QT measurement and heart rate correction during hypoglycemia

    DEFF Research Database (Denmark)

    Christensen, Toke Folke; Randløv, Jette; Christensen, Leif Engmann

    2010-01-01

    induced by intravenous injection of two insulin types in a cross-over design. QT measurements were done using the slope-intersect (SI) and manual annotation (MA) methods. Heart rate correction was done using Bazett's (QTcB) and Fridericia's (QTcF) formulas. Results. The SI method showed significant......Introduction. Several studies show that hypoglycemia causes QT interval prolongation. The aim of this study was to investigate the effect of QT measurement methodology, heart rate correction, and insulin types during hypoglycemia. Methods. Ten adult subjects with type 1 diabetes had hypoglycemia...... prolongation at hypoglycemia for QTcB (42(6) ms; P measuring the QT interval has...

  13. Robust efficient estimation of heart rate pulse from video

    Science.gov (United States)

    Xu, Shuchang; Sun, Lingyun; Rohde, Gustavo Kunde

    2014-01-01

    We describe a simple but robust algorithm for estimating the heart rate pulse from video sequences containing human skin in real time. Based on a model of light interaction with human skin, we define the change of blood concentration due to arterial pulsation as a pixel quotient in log space, and successfully use the derived signal for computing the pulse heart rate. Various experiments with different cameras, different illumination condition, and different skin locations were conducted to demonstrate the effectiveness and robustness of the proposed algorithm. Examples computed with normal illumination show the algorithm is comparable with pulse oximeter devices both in accuracy and sensitivity. PMID:24761294

  14. Airborne and total gamma absorbed dose rates at Patiala - India

    International Nuclear Information System (INIS)

    Tesfaye, Tilahun; Sahota, H.S.; Singh, K.

    1999-01-01

    The external gamma absorbed dose rate due to gamma rays originating from gamma emitting aerosols in air, is compared with the total external gamma absorbed dose rate at the Physics Department of Punjabi University, Patiala. It has been found out that the contribution, to the total external gamma absorbed dose rate, of radionuclides on particulate matter suspended in air is about 20% of the overall gamma absorbed dose rate. (author)

  15. Total Artificial Heart Bridge to Transplantation for a Patient With Occult Intracardiac Malignancy: Case Report.

    Science.gov (United States)

    Reich, H; Czer, L; Bannykh, S; De Robertis, M; Wolin, E; Amersi, F; Moriguchi, J; Kobashigawa, J; Arabia, F

    2015-09-01

    Malignancy is the leading cause of long-term morbidity and mortality after heart and other solid organ transplantation; therefore, great emphasis is placed on pre- and post-transplantation cancer screening. Even with meticulous screening during evaluation for heart transplant candidacy, an occult cancer may not be apparent. Here, we share the case of a 51-year-old man with refractory heart failure who underwent total artificial heart implantation as a bridge to transplantation with the surprise finding of an isolated deposit of metastatic carcinoid tumor nested within a left ventricular papillary muscle in his explanted heart. The primary ileal carcinoid tumor was identified and resected completely. After remaining cancer-free for 14 months, he was listed for heart transplantation and was transplanted 2 months later. He is currently 3.5 months out from heart transplantation and doing well, without evidence of recurring malignancy. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Prognostic value of ambulatory heart rate revisited in 6928 subjects from 6 populations

    DEFF Research Database (Denmark)

    Hansen, Tine Willum; Thijs, Lutgarde; Staessen, Jan A.

    2008-01-01

    The evidence relating mortality and morbidity to heart rate remains inconsistent. We performed 24-hour ambulatory blood pressure monitoring in 6928 subjects (not on beta-blockers; mean age: 56.2 years; 46.5% women) enrolled in prospective population studies in Denmark, Belgium, Japan, Sweden......, Uruguay, and China. We computed standardized hazard ratios for heart rate, while stratifying for cohort, and adjusting for blood pressure and other cardiovascular risk factors. Over 9.6 years (median), 850, 325, and 493 deaths accrued for total, cardiovascular, and noncardiovascular mortality......, respectively. The incidence of fatal combined with nonfatal end points was 805, 363, 439, and 324 for cardiovascular, stroke, cardiac, and coronary events, respectively. Twenty-four-hour heart rate predicted total (hazard ratio: 1.15) and noncardiovascular (hazard ratio: 1.18) mortality but not cardiovascular...

  17. Interagency registry for mechanically assisted circulatory support report on the total artificial heart.

    Science.gov (United States)

    Arabía, Francisco A; Cantor, Ryan S; Koehl, Devin A; Kasirajan, Vigneshwar; Gregoric, Igor; Moriguchi, Jaime D; Esmailian, Fardad; Ramzy, Danny; Chung, Joshua S; Czer, Lawrence S; Kobashigawa, Jon A; Smith, Richard G; Kirklin, James K

    2018-04-26

    We sought to better understand the patient population who receive a temporary total artificial heart (TAH) as bridge to transplant or as bridge to decision by evaluating data from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) database. We examined data related to survival, adverse events, and competing outcomes from patients who received TAHs between June 2006 and April 2017 and used hazard function analysis to explore risk factors for mortality. Data from 450 patients (87% men; mean age, 50 years) were available in the INTERMACS database. The 2 most common diagnoses were dilated cardiomyopathy (50%) and ischemic cardiomyopathy (20%). Risk factors for right heart failure were present in 82% of patients. Most patients were INTERMACS Profile 1 (43%) or 2 (37%) at implantation. There were 266 patients who eventually underwent transplantation, and 162 died. Overall 3-, 6-, and 12-month actuarial survival rates were 73%, 62%, and 53%, respectively. Risk factors for death included older age (p = 0.001), need for pre-implantation dialysis (p = 0.006), higher creatinine (p = 0.008) and lower albumin (p Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  18. The effect of relaxing music on heart rate and heart rate variability during ECG GATED-myocardial perfusion scintigraphy.

    Science.gov (United States)

    Tan, Yusuf Ziya; Ozdemir, Semra; Temiz, Ahmet; Celik, Fatmanur

    2015-05-01

    The positive changes in human behavior caused by relaxing music demonstrate the psychological effect of music on human body. A meta-analytical study has shown that relaxing music affects blood pressure and heart rate in coronary heart patients and cancer patients. The aim of our study is to research whether there is a significant effect on heart rate and heart rate variability due to listening to relaxing music during ECG GATED MPS imaging under gamma camera. The music group (n = 50 patients) could choose from 15 different musical types including folk music (no lyric). The other 50 patients were placed in a "no music group" and did not get headphones or any music. There was a statistically significant reduction in the heart rate of patients in the music group compared to those in the control group. Relaxing music provides great benefits to both patient and clinician. There is close relationship between relaxing music and health procedure, can use every area of the health noninvasiv, safe, cheap and is a method don't have side effect. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. A first step beyond traditional boundaries: destination therapy with the SynCardia total artificial heart.

    Science.gov (United States)

    Spiliopoulos, Sotirios; Koerfer, Reiner; Tenderich, Gero

    2014-06-01

    The SynCardia total artificial heart is currently used as a bridge to transplantation therapy in cases of irreversible, acute or chronic, biventricular heart failure. We describe the implementation of this technology in the context of destination therapy in a patient with an end-stage heart failure on grounds of primary amyloidosis. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Initial in vitro testing of a paediatric continuous-flow total artificial heart.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Karimov, Jamshid H; Horvath, David J; Sunagawa, Gengo; Byram, Nicole A; Kuban, Barry D; Moazami, Nader

    2018-06-01

    Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within ±5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.

  1. Functionality of the baroreceptor nerves in heart rate regulation

    DEFF Research Database (Denmark)

    Ottesen, Johnny T.; Olufsen, Mette

    2011-01-01

    are a consequence of the memory encapsulated by the models, and the nonlinearity gives rise to sigmoidal response curves. The nonlinear afferent baroreceptor models are coupled with an effector model, and the coupled model has been used to predict baroreceptor feedback regulation of heart rate during postural...... change from sitting to standing and during head-up tilt. The efferent model couples the afferent nerve paths to the sympathetic and parasympathetic outflow, and subsequently predicts the build up of an action potential at the sinus knot of the heart. In this paper, we analyze the nonlinear afferent model...... and show that the coupled model is able to predict heart rate regulation using blood pressure data as an input...

  2. Heart-Rate Recovery After Warm-up in Swimming: A Useful Predictor of Training Heart-Rate Response?

    Science.gov (United States)

    Ganzevles, Sander P M; de Haan, Arnold; Beek, Peter J; Daanen, Hein A M; Truijens, Martin J

    2017-07-01

    For training to be optimal, daily training load has to be adapted to the momentary status of the individual athlete, which is often difficult to establish. Therefore, the current study investigated the predictive value of heart-rate recovery (HRR) during a standardized warm-up for training load. Training load was quantified by the variation in heart rate during standardized training in competitive swimmers. Eight female and 5 male Dutch national-level swimmers participated in the study. They all performed 3 sessions consisting of a 300-m warm-up test and a 10 × 100-m training protocol. Both protocols were swum in front crawl at individually standardized velocities derived from an incremental step test. Velocity was related to 75% and 85% heart-rate reserve (% HR res ) for the warm-up and training, respectively. Relative HRR during the first 60 s after the warm-up (HR Rw-up ) and differences between the actual and intended heart rate for the warm-up and the training (ΔHR w-up and ΔHR tr ) were determined. No significant relationship between HRR w-up and ΔHR tr was found (F 1,37 = 2.96, P = .09, R 2 = .07, SEE = 4.65). There was considerable daily variation in ΔHR tr at a given swimming velocity (73-93% HR res ). ΔHR w-up and ΔHR tr were clearly related (F 1,37 = 74.31, P warm-up does not predict heart rate during a directly subsequent and standardized training session. Instead, heart rate during the warm-up protocol seems a promising alternative for coaches to make daily individual-specific adjustments to training programs.

  3. Moderate hypothermia technique for chronic implantation of a total artificial heart in calves.

    Science.gov (United States)

    Karimov, Jamshid H; Grady, Patrick; Sinkewich, Martin; Sunagawa, Gengo; Dessoffy, Raymond; Byram, Nicole; Moazami, Nader; Fukamachi, Kiyotaka

    2017-06-01

    The benefit of whole-body hypothermia in preventing ischemic injury during cardiac surgical operations is well documented. However, application of hypothermia during in vivo total artificial heart implantation has not become widespread because of limited understanding of the proper techniques and restrictions implied by constitutional and physiological characteristics specific to each animal model. Similarly, the literature on hypothermic set-up in total artificial heart implantation has also been limited. Herein we present our experience using hypothermia in bovine models implanted with the Cleveland Clinic continuous-flow total artificial heart.

  4. A healthy heart is not a metronome: an integrative review of the heart's anatomy and heart rate variability.

    Science.gov (United States)

    Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L

    2014-01-01

    Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  5. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability

    OpenAIRE

    E.R. Migliaro; P. Contreras; S. Bech; A. Etxagibel; M. Castro; R. Ricca; K. Vicente

    2001-01-01

    In order to assess the relative influence of age, resting heart rate (HR) and sedentary life style, heart rate variability (HRV) was studied in two different groups. The young group (YG) consisted of 9 sedentary subjects aged 15 to 20 years (YG-S) and of 9 nonsedentary volunteers (YG-NS) also aged 15 to 20. The elderly sedentary group (ESG) consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min). R-R variability was calculated in the time-...

  6. Heart Rate Monitors Promote Physical Education for Children

    Science.gov (United States)

    Tipton, Jan; Sander, Allan N.

    2004-01-01

    National health and fitness data suggests that a significant percentage of children are not on a pathway to leading healthy, physically active lifestyles. Many children are leading sedentary lifestyles due to a lack of opportunity, success, or self-motivation in physical activity. Programs that highlight the use of heart rate monitors offer a…

  7. Decreased heart rate variability in surgeons during night shifts

    DEFF Research Database (Denmark)

    Amirian, Ilda; Toftegård Andersen, Lærke; Rosenberg, Jacob

    2014-01-01

    BACKGROUND: Heart rate variability (HRV) has been used as a measure of stress and mental strain in surgeons. Low HRV has been associated with death and increased risk of cardiac events in the general population. The aim of this study was to clarify the effect of a 17-hour night shift on surgeons'...

  8. Gonadal hormones and heart rate as an emotional response

    NARCIS (Netherlands)

    de Loos, Wolter Statius

    1988-01-01

    Animai experiments may give information on the physiology of hormones under stress conditions. The model for the investigation of acute emotional stress in animals that has been chosen permits the study of heart rate in freely moving laboratory rats as a sensitive psychophysiological parameter, This

  9. Heart Rate Variability: Effect of Exercise Intensity on Postexercise Response

    Science.gov (United States)

    James, David V. B.; Munson, Steven C.; Maldonado-Martin, Sara; De Ste Croix, Mark B. A.

    2012-01-01

    The purpose of the present study was to investigate the influence of two exercise intensities (moderate and severe) on heart rate variability (HRV) response in 16 runners 1 hr prior to (-1 hr) and at +1 hr, +24 hr, +48 hr, and +72 hr following each exercise session. Time domain indexes and a high frequency component showed a significant decrease…

  10. Retrospective low heart rate variability overview in Jos, Nigeria ...

    African Journals Online (AJOL)

    Result: Subjects with low HRV were older (51 vs 42, p=<0.05) years with low mean heart rate p=<0.05, compared to those with normal HRV. They all had severe features of cardiac dysfunction. Females with low HRV had decreased frequency of premature atrial contraction (PACs) (52% vs 78%). Only 5 (28%) cases out of ...

  11. Heart rate variability | Lutfi | Sudan Journal of Medical Sciences

    African Journals Online (AJOL)

    An important outcome of such analysis is heart rate variability (HRV), which is widely accepted to have prognostic significance in patients with cardiovascular diseases especially after acute myocardial infarction. This is because HRV represents one of the most helpful markers of autonomic balance and hence can predict ...

  12. Heart rate variability analysis in acute poisoning by cholinesterase inhibitors

    OpenAIRE

    JEONG, JINWOO; KIM, YONGIN

    2017-01-01

    Heart rate variability (HRV) has been associated with a variety of clinical situations. However, few studies have examined the association between HRV and acute poisoning. Organophosphate (OP) and carbamate inhibit esterase enzymes, particularly acetylcholinesterase, resulting in an accumulation of acetylcholine and thereby promoting excessive activation of corresponding receptors. Because diagnosis and treatment of OP and carbamate poisoning greatly depend on...

  13. Continuous measurement of heart rate variability following carbon ...

    African Journals Online (AJOL)

    Background: Previous studies of autonomic nervous system activity through analysis of heart rate variability (HRV) have demonstrated increased sympathetic activity during positive-pressure pneumoperitoneum. We employed an online, continuous method for rapid HRV analysis (MemCalc™, Tarawa, Suwa Trust, Tokyo, ...

  14. Simplifying cardiovascular risk estimation using resting heart rate.

    LENUS (Irish Health Repository)

    Cooney, Marie Therese

    2010-09-01

    Elevated resting heart rate (RHR) is a known, independent cardiovascular (CV) risk factor, but is not included in risk estimation systems, including Systematic COronary Risk Evaluation (SCORE). We aimed to derive risk estimation systems including RHR as an extra variable and assess the value of this addition.

  15. Anti-Hyperlipidaemic and Heart Rate Lowering Effects of Aqueous ...

    African Journals Online (AJOL)

    The anti-hyperlipidaemic and heart rate lowering potential of aqueous leaf extract of Viscum album (mistletoe) in hypercholesterolaemic rats was investigated in this study. The lethality studies showed that the aqueous extract of the plant had an LD50 value of 452.20mg/kg by intraperitoneal route. There were significant ...

  16. Continuous measurement of heart rate variability following carbon ...

    African Journals Online (AJOL)

    2010-07-16

    Jul 16, 2010 ... Power spectral analysis of the electrocardiographic R-R interval [heart rate variability: (HRV)] is a well known, non- invasive method for assessing autonomic nervous activity.1. Studies using HRV analysis during positive-pressure pneumoperitoneum (PPP) have demonstrated increased sympathetic ...

  17. Blood pressure and heart rate adjustment following acute Frenkel's ...

    African Journals Online (AJOL)

    Background: Frenkel's ambulatory activity has been routinely employed by physiotherapists for rehabilitation of gait coordination, however, its immediate influence on blood pressure and heart rate has not been investigated. Objective: To investigate the acute effect of Frenkel's ambulatory activity on blood pressure and ...

  18. Prediction of maximal heart rate: comparison using a novel and ...

    African Journals Online (AJOL)

    Prediction of maximal heart rate: comparison using a novel and conventional equation. LR Keytel, E Mukwevho, MA Will, M Lambert. Abstract. No Abstract. African Journal for Physical, Health Education, Recreation and Dance Vol. 11(3) 2005: 269-277. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL ...

  19. Heart rate variability is reduced during acute uncomplicated diverticulitis

    DEFF Research Database (Denmark)

    Huang, Chenxi; Alamili, Mahdi; Rosenberg, Jacob

    2016-01-01

    BACKGROUND: The aim of the present study was to report the trajectory of heart rate variability (HRV) indices during a low-grade acute inflammation and their associations to biomarkers for infection. METHODS: Twelve patients with uncomplicated acute diverticulitis completed this observational study...

  20. Heart Rate Variability Interventions for Concussion and Rehabilitation

    Directory of Open Access Journals (Sweden)

    Robert Lake Conder

    2014-08-01

    Full Text Available The study of Heart Rate Variability (HRV has emerged as an essential component of cardiovascular health, as well as a physiological mechanism by which one can increase the interactive communication between the cardiac and the neurocognitive systems (i.e., the body and the brain. It is well-established that lack of heart rate variability implies cardiopathology, morbidity, reduced quality-of-life, and precipitous mortality. On the positive, optimal heart rate variability has been associated with good cardiovascular health, autonomic nervous system (ANS control, emotional regulation, and enhanced neurocognitive processing. In addition to health benefits, optimal HRV has been shown to improve neurocognitive performance by enhancing focus, visual acuity and readiness, and by promoting emotional regulation needed for peak performance. In concussed athletes and soldiers, concussions not only alter brain connectivity, but also alter cardiac functioning and impair cardiovascular performance upon exertion. Altered sympathetic and parasympathetic balance in the ANS has been postulated as a critical factor in refractory Post Concussive Syndrome (PCS. This article will review both the pathological aspects of reduced heart rate variability on athletic performance, as well as the cardiovascular and cerebrovascular components of concussion and PCS. Additionally, this article will review interventions with HRV biofeedback (HRV BFB training as a promising and underutilized treatment for sports and military-related concussion. Finally, this article will review research and promising case studies pertaining to use of HRV BFB for enhancement of cognition and performance, with applicability to concussion rehabilitation.

  1. Individual variability in heart rate recovery after standardized submaximal exercise

    NARCIS (Netherlands)

    van der Does, Hendrike; Brink, Michel; Visscher, Chris; Lemmink, Koen

    2012-01-01

    To optimize performance, coaches and athletes are always looking for the right balance between training load and recovery. Therefore, closely monitoring of athletes is important. Heart rate recovery (HRR) after standardized sub maximal exercise has been proposed as a useful variable to monitor

  2. The intubating laryngeal mask produces less heart rate response to ...

    African Journals Online (AJOL)

    Pc

    We compared heart rate and blood pressure changes to intubation produced by conventional laryngoscopic-guided intubation to those produced by blind intubation through the intubating laryngeal mask (ILM) in normotensive adults with normal airways. Forty paralysed, anaesthetised adults undergoing elective surgery ...

  3. Heart Rate Variability and Drawing Impairment in Hypoxemic COPD

    Science.gov (United States)

    Incalzi, Raffaele Antonelli; Corsonello, Andrea; Trojano, Luigi; Pedone, Claudio; Acanfora, Domenico; Spada, Aldo; D'Addio, Gianni; Maestri, Roberto; Rengo, Franco; Rengo, Giuseppe

    2009-01-01

    We studied 54 patients with hypoxemic chronic obstructive pulmonary disease (COPD). The Mini Mental State Examination and the Mental Deterioration Battery were used for neuropsychological assessment. Heart rate variability (HRV) was assessed based on 24-h Holter ECG recording. Mann-Whitney test was used to compare HRV parameters of patients…

  4. Effects of Exercise Training on Heart Rate Variability in Chagas Heart Disease

    Directory of Open Access Journals (Sweden)

    Bruno Ramos Nascimento

    2014-09-01

    Full Text Available Background: Heart rate variability (HRV is a marker of autonomic dysfunction severity. The effects of physical training on HRV indexes in Chagas heart disease (CHD are not well established. Objective: To evaluate the changes in HRV indexes in response to physical training in CHD. Methods: Patients with CHD and left ventricular (LV dysfunction, physically inactive, were randomized either to the intervention (IG, N = 18 or control group (CG, N = 19. The IG participated in a 12-week exercise program consisting of 3 sessions/week. Results: Mean age was 49.5 ± 8 years, 59% males, mean LVEF was 36.3 ± 7.8%. Baseline HRV indexes were similar between groups. From baseline to follow-up, total power (TP: 1653 (IQ 625 - 3418 to 2794 (1617 - 4452 ms, p = 0.02 and very low frequency power: 586 (290 - 1565 to 815 (610 - 1425 ms, p = 0.047 increased in the IG, but not in the CG. The delta (post - pre HRV indexes were similar: SDNN 11.5 ± 30.0 vs. 3.7 ± 25.1 ms. p = 0.10; rMSSD 2 (6 - 17 vs. 1 (21 - 9 ms. p = 0.43; TP 943 (731 - 3130 vs. 1780 (921 - 2743 Hz. p = 0.46; low frequency power (LFP 1.0 (150 - 197 vs. 60 (111 - 146 Hz. p = 0.85; except for high frequency power, which tended to increase in the IG: 42 (133 - 92 vs. 79 (61 - 328 Hz. p = 0.08. Conclusion: In the studied population, the variation of HRV indexes was similar between the active and inactive groups. Clinical improvement with physical activity seems to be independent from autonomic dysfunction markers in CHD.

  5. Low heart rate variability in patients with clinical burnout.

    Science.gov (United States)

    Lennartsson, Anna-Karin; Jonsdottir, Ingibjörg; Sjörs, Anna

    2016-12-01

    Several studies have shown that acute psychosocial stress and chronic psychosocial stress reduce heart rate variability (HRV). It is likely that individuals suffering from burnout have reduced HRV, as a consequence of the long-term stress exposure. This study investigated HRV in 54 patients with clinical burnout (40 women and 14 men) and in 55 individuals reporting low burnout scores (healthy; 24 women and 31 men) and 52 individuals reporting high burnout scores (non-clinical burnout; 33 women and 19 men). The participants underwent a 300s ECG recording in the supine position. Standard deviation of normal R-R intervals (SDNN) and the root mean square of successive normal interval differences (RMSSD) were derived from time domain HRV analysis. Frequency domain HRV measures; total power (TP), low frequency power (LF), high frequency power (HF), and LF/HF ratio were calculated. All HRV measures, except LF/HF ratio, were lower in the clinical burnout patients compared to both the non-clinical burnout group and the healthy group. The difference was larger between the patients and the healthy group than between the patients and the non-clinical burnout group. HRV did not differ significantly between the non-clinical burnout group and the healthy group. Low HRV in burnout patients may constitute one of the links to associated adverse health, since low HRV reflects low parasympathetic activity - and accordingly low anabolic/regenerative activity. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Heart rate never lies: interventional cardiologist and Braude's quote revised.

    Science.gov (United States)

    Cook, Stéphane; Stauffer, Jean-Christophe; Goy, Jean-Jacques; Graf, Denis; Puricel, Serban; Frobert, Aurélien; Muller, Olivier; Togni, Mario; Arroyo, Diego

    2016-01-01

    Interventional cardiologists may be immune to stress, allowing them to perform complex percutaneous interventions under pressure. To assess heart rate (HR) variations as a surrogate marker of stress of interventional cardiologists during percutaneous cardiac procedures and in every-day life. This is a single-centre observational study including a total of six male interventional cardiologists performing coronary interventions and pacemaker implantations. Participants were asked to record their HR with the Apple Watch Device during procedures, every-day life and control activities such as outpatient consultations, sport, marital conflicts and sexual intercourse. Average daily HR was 88±17 bpm. During work days, HR increased significantly during procedures (90±17 bpm) compared with days outside the cathlab (87±17 bpm, p=0.02). The average HR was higher during a regular week working (88±16 bpm) compared with weekends off (84±18 bpm, p=0.002). Complex cardiac procedures were associated with higher HR up to 122 bpm. Peak HR were higher during physical exertion. Of note, participants complained of hypersexuality and mania after night shifts. Work and especially percutaneous cardiac procedures increase HR independently of physical exertion suggesting that interventional cardiologists experience mental stress and emotions.

  7. Estimation of human core temperature from sequential heart rate observations

    International Nuclear Information System (INIS)

    Buller, Mark J; Tharion, William J; Cheuvront, Samuel N; Montain, Scott J; Kenefick, Robert W; Castellani, John; Latzka, William A; Hoyt, Reed W; Roberts, Warren S; Richter, Mark; Jenkins, Odest Chadwicke

    2013-01-01

    Core temperature (CT) in combination with heart rate (HR) can be a good indicator of impending heat exhaustion for occupations involving exposure to heat, heavy workloads, and wearing protective clothing. However, continuously measuring CT in an ambulatory environment is difficult. To address this problem we developed a model to estimate the time course of CT using a series of HR measurements as a leading indicator using a Kalman filter. The model was trained using data from 17 volunteers engaged in a 24 h military field exercise (air temperatures 24–36 °C, and 42%–97% relative humidity and CTs ranging from 36.0–40.0 °C). Validation data from laboratory and field studies (N = 83) encompassing various combinations of temperature, hydration, clothing, and acclimation state were examined using the Bland–Altman limits of agreement (LoA) method. We found our model had an overall bias of −0.03 ± 0.32 °C and that 95% of all CT estimates fall within ±0.63 °C (>52 000 total observations). While the model for estimating CT is not a replacement for direct measurement of CT (literature comparisons of esophageal and rectal methods average LoAs of ±0.58 °C) our results suggest it is accurate enough to provide practical indication of thermal work strain for use in the work place. (paper)

  8. Estimation of human core temperature from sequential heart rate observations.

    Science.gov (United States)

    Buller, Mark J; Tharion, William J; Cheuvront, Samuel N; Montain, Scott J; Kenefick, Robert W; Castellani, John; Latzka, William A; Roberts, Warren S; Richter, Mark; Jenkins, Odest Chadwicke; Hoyt, Reed W

    2013-07-01

    Core temperature (CT) in combination with heart rate (HR) can be a good indicator of impending heat exhaustion for occupations involving exposure to heat, heavy workloads, and wearing protective clothing. However, continuously measuring CT in an ambulatory environment is difficult. To address this problem we developed a model to estimate the time course of CT using a series of HR measurements as a leading indicator using a Kalman filter. The model was trained using data from 17 volunteers engaged in a 24 h military field exercise (air temperatures 24-36 °C, and 42%-97% relative humidity and CTs ranging from 36.0-40.0 °C). Validation data from laboratory and field studies (N = 83) encompassing various combinations of temperature, hydration, clothing, and acclimation state were examined using the Bland-Altman limits of agreement (LoA) method. We found our model had an overall bias of -0.03 ± 0.32 °C and that 95% of all CT estimates fall within ±0.63 °C (>52 000 total observations). While the model for estimating CT is not a replacement for direct measurement of CT (literature comparisons of esophageal and rectal methods average LoAs of ±0.58 °C) our results suggest it is accurate enough to provide practical indication of thermal work strain for use in the work place.

  9. Wavelet and receiver operating characteristic analysis of heart rate variability

    Science.gov (United States)

    McCaffery, G.; Griffith, T. M.; Naka, K.; Frennaux, M. P.; Matthai, C. C.

    2002-02-01

    Multiresolution wavelet analysis has been used to study the heart rate variability in two classes of patients with different pathological conditions. The scale dependent measure of Thurner et al. was found to be statistically significant in discriminating patients suffering from hypercardiomyopathy from a control set of normal subjects. We have performed Receiver Operating Characteristc (ROC) analysis and found the ROC area to be a useful measure by which to label the significance of the discrimination, as well as to describe the severity of heart dysfunction.

  10. Summary of the clinical use of the Symbion total artificial heart: a registry report.

    Science.gov (United States)

    Johnson, K E; Prieto, M; Joyce, L D; Pritzker, M; Emery, R W

    1992-01-01

    Several models of total artificial hearts have been used for transient or permanent circulatory support in patients with decompensation. The most successful and widely used device, however, has been the Symbion total artificial heart. From Dec. 12, 1982, to Jan. 1, 1991, 180 Symbion total artificial hearts were implanted in 176 patients in 28 centers. Five patients received a Symbion total artificial heart as a permanent circulatory support device, whereas 171 patients received the device as a bridge to heart transplantation. Of the 175 bridge devices (171 patients) 141 were Symbion J7-70 hearts and 34 were Symbion J7-100 hearts. Four patients received two total artificial hearts, the second one after the failure of a transplanted heart because of either rejection (two patients) or donor heart failure (2 patients). Most of the recipients were males (152). The age was 42 +/- 12 years (mean +/- SD) with a weight of 74 +/- 14 kg. The most common indications for implantation included deterioration while awaiting heart transplant (36%) and acute cardiogenic shock (32%). The cause of heart disease was primarily ischemic (52%) and idiopathic (35%) cardiomyopathy. Duration of implantation ranged from 0 to 603 days (mean 25 +/- 64 days). One hundred three (60%) patients had the device less than 2 weeks, 37 (22%) between 2 to 4 weeks and 31 (18%) more than 4 weeks. Complications during implantation included infection (37%), thromboembolic events (stroke 7%, transient ischemic attack 4%), kidney failure requiring dialysis (20%), bleeding requiring intervention (26%), and device malfunction (4%). Of the 171 patients, 118 (69%) underwent orthotopic heart transplantation. Actuarial survival for all patients with implants was 62% for 30 days and 42% for 1 year, and for patients with transplants was 72% for 30 days and 57% for 1 year. The main causes of death were sepsis (33%), multiorgan failure (21%), and posttransplant rejection (10%). The results indicate a relative success of

  11. Patterns of Interspecific Variation in the Heart Rates of Embryonic Reptiles

    Science.gov (United States)

    Du, Wei-Guo; Ye, Hua; Zhao, Bo; Pizzatto, Ligia; Ji, Xiang; Shine, Richard

    2011-01-01

    New non-invasive technologies allow direct measurement of heart rates (and thus, developmental rates) of embryos. We applied these methods to a diverse array of oviparous reptiles (24 species of lizards, 18 snakes, 11 turtles, 1 crocodilian), to identify general influences on cardiac rates during embryogenesis. Heart rates increased with ambient temperature in all lineages, but (at the same temperature) were faster in lizards and turtles than in snakes and crocodilians. We analysed these data within a phylogenetic framework. Embryonic heart rates were faster in species with smaller adult sizes, smaller egg sizes, and shorter incubation periods. Phylogenetic changes in heart rates were negatively correlated with concurrent changes in adult body mass and residual incubation period among the lizards, snakes (especially within pythons) and crocodilians. The total number of embryonic heart beats between oviposition and hatching was lower in squamates than in turtles or the crocodilian. Within squamates, embryonic iguanians and gekkonids required more heartbeats to complete development than did embryos of the other squamate families that we tested. These differences plausibly reflect phylogenetic divergence in the proportion of embryogenesis completed before versus after laying. PMID:22174948

  12. Heart rate detection from an electronic weighing scale

    International Nuclear Information System (INIS)

    González-Landaeta, R; Casas, O; Pallàs-Areny, R

    2008-01-01

    We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weighing scales to assess their capability to detect the BCG force signal. Static sensitivities ranged from 490 nV V −1 N −1 to 1670 nV V −1 N −1 . The frequency response depended on the subject's mass but it was broad enough for heart rate estimation. We have designed an electronic pulse detection system based on off-the-shelf integrated circuits to sense heart-beat-related force variations of about 0.24 N. The signal-to-noise ratio of the main peaks of the force signal detected was higher than 30 dB. A Bland–Altman plot was used to compare the RR time intervals estimated from the ECG and BCG force signals for 17 volunteers. The error was ±21 ms, which makes the proposed technique suitable for short-term monitoring of the heart rate

  13. Modest weight loss in moderately overweight postmenopausal women improves heart rate variability

    DEFF Research Database (Denmark)

    Mouridsen, Mette Rauhe; Bendsen, Nathalie Tommerup; Astrup, Arne

    2013-01-01

    Purpose: To evaluate the effects of weight loss on heart rate (HR) and heart rate variability (HRV) parameters in overweight postmenopausal women. Design and Methods: Forty-nine overweight postmenopausal women with an average body mass index of 28.8 1.9 kg/m2 underwent a 12-week dietary weight......-to-normal intervals for each 5-min period (SDNNindex). Baseline body fat mass (FM%) and changes in body composition was determined by dual X-ray absorptiometry. Before and after the weight-loss period, total abdominal fat, intra-abdominal fat (IAAT), and subcutaneous abdominal fat (SCAT) were measured by single...

  14. Heart Rate-Determined Physical Activity In New Zealand School Children: A Cross- Sectional Study

    OpenAIRE

    Michael J. Hamlin; Mick Grimley; Vicki Cowley; Chris D. Price; Jill M. Hargreaves; Jenny J. Ross

    2011-01-01

    The aim of this study was to examine current levels of physical activity determined via heart rate monitoring. A total of 176 children (85 boys, 91 girls) aged 5-13 years wore sealed Polar heart rate monitors for at least 10 hours per day on at least 3 days. Mean daily minutes of moderate to vigorous-intensity physical activity was 65 ± 43 (mean ± SD) for boys and 54 ± 37 for girls. Daily minutes of vigorous-intensity activity was 31 ± 24 and 24 ± 21 for boys and girls respectively. Significa...

  15. Total Artificial Heart Implantation After Undifferentiated High-Grade Sarcoma Excision.

    Science.gov (United States)

    Kremer, Jamila; Farag, Mina; Arif, Rawa; Brcic, Andreas; Sabashnikov, Anton; Schmack, Bastian; Popov, Aron-Frederik; Karck, Matthias; Dohmen, Pascal M; Ruhparwar, Arjang; Weymann, Alexander

    2016-11-02

    BACKGROUND Total artificial heart (TAH) implantation in patients with aggressive tumor infiltration of the heart can be challenging. CASE REPORT We report on a patient with a rare primary undifferentiated high-grade spindle cell sarcoma of the mitral valve and in the left atrium, first diagnosed in 2014. The referring center did a first resection in 2014. In the course of 17 months, computer tomography (CT) scan again showed massive invasion of the mitral valve and left atrium. Partial resection and mitral valve replacement was not an option. We did a subtotal heart excision with total artificial heart implantation. In this report we discuss complications, risk factors, and perioperative management of this patient. CONCLUSIONS Patients with aggressive tumors of the heart can be considered for TAH implantation.

  16. Heart Disease Death Rates Among Blacks and Whites Aged ≥35 Years - United States, 1968-2015.

    Science.gov (United States)

    Van Dyke, Miriam; Greer, Sophia; Odom, Erika; Schieb, Linda; Vaughan, Adam; Kramer, Michael; Casper, Michele

    2018-03-30

    Heart disease is the leading cause of death in the United States. In 2015, heart disease accounted for approximately 630,000 deaths, representing one in four deaths in the United States. Although heart disease death rates decreased 68% for the total population from 1968 to 2015, marked disparities in decreases exist by race and state. 1968-2015. The National Vital Statistics System (NVSS) data on deaths in the United States were abstracted for heart disease using diagnosis codes from the eighth, ninth, and tenth revisions of the International Classification of Diseases (ICD-8, ICD-9, and ICD-10) for 1968-2015. Population estimates were obtained from NVSS files. National and state-specific heart disease death rates for the total population and by race for adults aged ≥35 years were calculated for 1968-2015. National and state-specific black-white heart disease mortality ratios also were calculated. Death rates were age standardized to the 2000 U.S. standard population. Joinpoint regression was used to perform time trend analyses. From 1968 to 2015, heart disease death rates decreased for the total U.S. population among adults aged ≥35 years, from 1,034.5 to 327.2 per 100,000 population, respectively, with variations in the magnitude of decreases by race and state. Rates decreased for the total population an average of 2.4% per year, with greater average decreases among whites (2.4% per year) than blacks (2.2% per year). At the national level, heart disease death rates for blacks and whites were similar at the start of the study period (1968) but began to diverge in the late 1970s, when rates for blacks plateaued while rates for whites continued to decrease. Heart disease death rates among blacks remained higher than among whites for the remainder of the study period. Nationwide, the black-white ratio of heart disease death rates increased from 1.04 in 1968 to 1.21 in 2015, with large increases occurring during the 1970s and 1980s followed by small but steady

  17. Anatomy of the bovine ascending aorta and brachiocephalic artery found unfavorable for total artificial heart implant.

    Science.gov (United States)

    Karimov, Jamshid H; Sunagawa, Gengo; Such, Kimberly A; Sale, Shiva; Golding, Leonard A R; Moazami, Nader; Fukamachi, Kiyotaka

    2015-12-01

    The biocompatibility assessment of the Cleveland Clinic continuous-flow total artificial heart is an important part of the device developmental program. Surgical and postoperative management are key factors in achieving optimal outcomes. However, the presence of vascular anatomical abnormalities in experimental animal models is often unpredictable and may worsen the expected outcomes. We report a technical impediment encountered during total artificial heart implantation complicated by unfavorable bovine anatomy of the ascending aorta and brachiocephalic arterial trunk.

  18. Automatic heart rate normalization for accurate energy expenditure normalization : an analysis of activities of daily living and heart rate features

    NARCIS (Netherlands)

    Altini, M.; Penders, J.; Vullers, R.J.M.; Amft, O.D.

    2014-01-01

    Introduction: This article is part of the Focus Theme of Methods of Information in Medicine on "Pervasive Intelligent Technologies for Health". Background: Energy Expenditure (EE) estimation algorithms using Heart Rate (HR) or a combination of accelerometer and HR data suffer from large error due to

  19. Diminution of Heart Rate Variability in Bipolar Depression

    Directory of Open Access Journals (Sweden)

    Brandon Hage

    2017-12-01

    Full Text Available Autonomic nervous system (ANS dysregulation in depression is associated with symptoms associated with the ANS. The beat-to-beat pattern of heart rate defined as heart rate variability (HRV provides a noninvasive portal to ANS function and has been proposed to represent a means of quantifying resting vagal tone. We quantified HRV in bipolar depressed (BDD patients as a measure of ANS dysregulation seeking to establish HRV as a potential diagnostic and prognostic biomarker for treatment outcome. Forty-seven BDD patients were enrolled. They were randomized to receive either escitalopram–celecoxib or escitalopram-placebo over 8 weeks in a double-blind study design. Thirty-five patients completed the HRV studies. Thirty-six healthy subjects served as controls. HRV was assessed at pretreatment and end of study and compared with that of controls. HRV was quantified and corrected for artifacts using an algorithm that incorporates time and frequency domains to address non-stationarity of the beat-to-beat heart rate pattern. Baseline high frequency-HRV (i.e., respiratory sinus arrhythmia was lower in BDD patients than controls, although the difference did not reach significance. Baseline low-frequency HRV was significantly lower in BDD patients (ln4.20 than controls (ln = 5.50 (p < 0.01. Baseline heart period was significantly shorter (i.e., faster heart rate in BDD patients than controls. No significant change in HRV parameters were detected over the course of the study with either treatment. These findings suggest that components of HRV may be diminished in BDD patients.

  20. [The influence of physical exercise on heart rate variability].

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Negrusz-Kawecka, Marta; Halawa, Bogumił

    2003-03-01

    Heart rate variability is controlled by the influence of autonomic nervous system, whereas one part of the system modulates the activity of the other. There is evidence of increased sympathetic activity in patients (pts) with essential hypertension. The aim of the study was to assess the persisting influence of increased sympathetic activity 30 min after moderate physical exercise on heart rate variability in patients with arterial hypertension. The study was performed in 19 patients (10 women, mean age 52.7 +/- 9.5 years and 9 men, mean age 37.7 +/- 8.8 years) with stage I (6 pts) and stage II (13 pts) arterial hypertension. All studied pts had sinus rhythm, were free of diabetes, coronary heart disease and congestive heart failure. 24-hour Holter monitoring was performed and for 30 min before the exercise test the pts stayed in supine rest. The exercise tests were performed between 10 and 11 a.m. Immediately after the exercise all pts stayed in supine position for 30 min. The heart rate variability parameters were studied using Holter monitoring system Medilog Optima Jet and were then analysed statistically. The mean energy expenditure during the exercise was 5.8 +/- 1.1 METs and the maximal heart rate was 148.1 +/- 20.3 bpm. All studied HRV parameters were significantly different in the assessed time period compared to the baseline values (p < 0.001). Significant correlation was found between the age of the studied patients and the mean RR interval, what can be considered as a hyperkinetic (hyperadrenergic) circulatory status and shorter RR interval in younger pts. Significant negative correlation between the age and SDNN parameter (r = -0.65, p < 0.001), 30 min after the exercise mirrors the prolonged adrenergic influence in older pts. The present study shows that the influence of moderate physical exercise on heart rate variability in pts with essential hypertension is extended over 30 min period after exercise and is more pronounced in older pts. The studies

  1. Determination of heart rate variability with an electronic stethoscope.

    Science.gov (United States)

    Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M

    2013-02-01

    Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.

  2. Heart Rate Variability Is Associated with Exercise Capacity in Patients with Cardiac Syndrome X.

    Directory of Open Access Journals (Sweden)

    Dai-Yin Lu

    Full Text Available Heart rate variability (HRV reflects the healthiness of autonomic nervous system, which is associated with exercise capacity. We therefore investigated whether HRV could predict the exercise capacity in the adults with cardiac syndrome X (CSX. A total of 238 subjects (57±12 years, 67.8% men, who were diagnosed as CSX by the positive exercise stress test and nearly normal coronary angiogram were enrolled. Power spectrum from the 24-hour recording of heart rate was analyzed in frequency domain using total power (TP and spectral components of the very low frequency (VLF, low frequency (LF and high frequency (HF ranges. Among the study population, 129 subjects with impaired exercise capacity during the treadmill test had significantly lower HRV indices than those with preserved exercise capacity (≥90% of the age predicted maximal heart rate. After accounting for age, sex, and baseline SBP and heart rate, VLF (odds ratio per 1SD and 95% CI: 2.02, 1.19-3.42, LF (1.67, 1.10-2.55, and TP (1.82, 1.17-2.83 remained significantly associated with preserved exercise capacity. In addition, increased HRV indices were also associated with increased exercise duration, rate-pressure product, and heart rate recovery, independent of age, body mass index, and baseline SBP and heart rate. In subgroup analysis, HRV indices demonstrated similar predictive values related to exercise capacity across various subpopulations, especially in the young. In patients with CSX, HRV was independently associated with exercise capacity, especially in young subjects. The healthiness of autonomic nervous system may have a role in modulating the exercise capacity in patients with CSX.

  3. Changes of heart rate variability and prefrontal oxygenation during Tai Chi practice versus arm ergometer cycling.

    Science.gov (United States)

    Lu, Xi; Hui-Chan, Christina Wan-Ying; Tsang, William Wai-Nam

    2016-11-01

    [Purpose] Exercise has been shown to improve cardiovascular fitness and cognitive function. Whether the inclusion of mind over exercise would increase parasympathetic control of the heart and brain activities more than general exercise at a similar intensity is not known. The aim of this study was to compare the effects of Tai Chi (mind-body exercise) versus arm ergometer cycling (body-focused exercise) on the heart rate variability and prefrontal oxygenation level. [Subjects and Methods] A Tai Chi master was invited to perform Tai Chi and arm ergometer cycling with similar exercise intensity on two separate days. Heart rate variability and prefrontal oxyhemoglobin levels were measured continuously by a RR recorder and near-infrared spectroscopy, respectively. [Results] During Tai Chi exercise, spectral analysis of heart rate variability demonstrated a higher high-frequency power as well as a lower low-frequency/high-frequency ratio than during ergometer cycling, suggesting increased parasympathetic and decreased sympathetic control of the heart. Also, prefrontal oxyhemoglobin and total hemoglobin levels were higher than those during arm ergometer exercise. [Conclusion] These findings suggest that increased parasympathetic control of the heart and prefrontal activities may be associated with Tai Chi practice. Having a "mind" component in Tai Chi could be more beneficial for older adults' cardiac health and cognitive function than body-focused ergometer cycling.

  4. The evolving role of the total artificial heart in the management of end-stage congenital heart disease and adolescents.

    Science.gov (United States)

    Ryan, Thomas D; Jefferies, John L; Zafar, Farhan; Lorts, Angela; Morales, David L S

    2015-01-01

    Advances in medical therapies have yielded improvement in morbidity and a decrease in mortality for patients with congenital heart disease, both surgically palliated and uncorrected. An unintended consequence is a cohort of adolescent and adult patients with heart failure who require alternative therapies. One intriguing option is placement of a total artificial heart (TAH) either as a bridge to transplant or as a destination therapy. Of the 1091 Jarvik-7 type TAH (Symbion, CardioWest and SynCardia) placed between 1985 and 2012, only 24 have been performed in patients with congenital heart disease, and a total of 51 were placed in patients younger than 21. At our institution, the SynCardia TAH was implanted in a 19-year-old patient with cardiac allograft failure because of chronic rejection and related multisystem organ failure including need for hemodialysis. Over the next year, she was nutritionally and physically rehabilitated, as were her end organs, allowing her to come off dialysis, achieve normal renal function and eventually be successfully transplanted. Given the continued growth of adolescent and adult congenital heart disease populations with end-stage heart failure, the TAH may offer therapeutic options where previously there were few. In addition, smaller devices such as the SynCardia 50/50 will open the door for applications in smaller children. The Freedom Driver offers the chance for patients to leave the hospital with a TAH, as does the AbioCor, which is a fully implantable TAH option. In this report, we review the history of the TAH and potential applications in adolescent patients and congenital heart disease.

  5. Identification of heart rate-associated loci and their effects on cardiac conduction and rhythm disorders

    DEFF Research Database (Denmark)

    den Hoed, Marcel; Eijgelsheim, Mark; Esko, Tõnu

    2013-01-01

    of dilated cardiomyopathy, congenital heart failure and/or sudden cardiac death. In addition, genetic susceptibility to increased heart rate is associated with altered cardiac conduction and reduced risk of sick sinus syndrome, and both heart rate-increasing and heart rate-decreasing variants associate...

  6. Features of Heart Rate Variability Capture Regulatory Changes During Kangaroo Care in Preterm Infants.

    Science.gov (United States)

    Kommers, Deedee R; Joshi, Rohan; van Pul, Carola; Atallah, Louis; Feijs, Loe; Oei, Guid; Bambang Oetomo, Sidarto; Andriessen, Peter

    2017-03-01

    To determine whether heart rate variability (HRV) can serve as a surrogate measure to track regulatory changes during kangaroo care, a period of parental coregulation distinct from regulation within the incubator. Nurses annotated the starting and ending times of kangaroo care for 3 months. The pre-kangaroo care, during-kangaroo care, and post-kangaroo care data were retrieved in infants with at least 10 accurately annotated kangaroo care sessions. Eight HRV features (5 in the time domain and 3 in the frequency domain) were used to visually and statistically compare the pre-kangaroo care and during-kangaroo care periods. Two of these features, capturing the percentage of heart rate decelerations and the extent of heart rate decelerations, were newly developed for preterm infants. A total of 191 kangaroo care sessions were investigated in 11 preterm infants. Despite clinically irrelevant changes in vital signs, 6 of the 8 HRV features (SD of normal-to-normal intervals, root mean square of the SD, percentage of consecutive normal-to-normal intervals that differ by >50 ms, SD of heart rate decelerations, high-frequency power, and low-frequency/high-frequency ratio) showed a visible and statistically significant difference (P heart rate decelerations. HRV-based features may be clinically useful for capturing the dynamic changes in autonomic regulation in response to kangaroo care and other changes in environment and state. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. General anesthesia suppresses normal heart rate variability in humans

    Science.gov (United States)

    Matchett, Gerald; Wood, Philip

    2014-06-01

    The human heart normally exhibits robust beat-to-beat heart rate variability (HRV). The loss of this variability is associated with pathology, including disease states such as congestive heart failure (CHF). The effect of general anesthesia on intrinsic HRV is unknown. In this prospective, observational study we enrolled 100 human subjects having elective major surgical procedures under general anesthesia. We recorded continuous heart rate data via continuous electrocardiogram before, during, and after anesthesia, and we assessed HRV of the R-R intervals. We assessed HRV using several common metrics including Detrended Fluctuation Analysis (DFA), Multifractal Analysis, and Multiscale Entropy Analysis. Each of these analyses was done in each of the four clinical phases for each study subject over the course of 24 h: Before anesthesia, during anesthesia, early recovery, and late recovery. On average, we observed a loss of variability on the aforementioned metrics that appeared to correspond to the state of general anesthesia. Following the conclusion of anesthesia, most study subjects appeared to regain their normal HRV, although this did not occur immediately. The resumption of normal HRV was especially delayed on DFA. Qualitatively, the reduction in HRV under anesthesia appears similar to the reduction in HRV observed in CHF. These observations will need to be validated in future studies, and the broader clinical implications of these observations, if any, are unknown.

  8. Hemodynamic deterioration during extracorporeal membrane oxygenation weaning in a patient with a total artificial heart.

    Science.gov (United States)

    Hosseinian, Leila; Levin, Matthew A; Fischer, Gregory W; Anyanwu, Anelechi C; Torregrossa, Gianluca; Evans, Adam S

    2015-01-01

    The Total Artificial Heart (Syncardia, Tucson, AZ) is approved for use as a bridge-to-transplant or destination therapy in patients who have irreversible end-stage biventricular heart failure. We present a unique case, in which the inferior vena cava compression by a total artificial heart was initially masked for days by the concurrent placement of an extracorporeal membrane oxygenation cannula. This is the case of a 33-year-old man admitted to our institution with recurrent episodes of ventricular tachycardia requiring emergent total artificial heart and venovenous extracorporeal membrane oxygenation placement. This interesting scenario highlights the importance for critical care physicians to have an understanding of exact anatomical localization of a total artificial heart, extracorporeal membrane oxygenation, and their potential interactions. In total artificial heart patients with hemodynamic compromise or reduced device filling, consideration should always be given to venous inflow compression, particularly in those with smaller body surface area. Transesophageal echocardiogram is a readily available diagnostic tool that must be considered standard of care, not only in the operating room but also in the ICU, when dealing with this complex subpopulation of cardiac patients.

  9. Onset of decreased heart work is correlated with increased heart rate and shortened QT interval in high-carbohydrate fed overweight rats.

    Science.gov (United States)

    Durak, Aysegul; Olgar, Yusuf; Tuncay, Erkan; Karaomerlioglu, Irem; Kayki Mutlu, Gizem; Arioglu Inan, Ebru; Altan, Vecdi Melih; Turan, Belma

    2017-11-01

    Mechanical activity of the heart is adversely affected in metabolic syndrome (MetS) characterized by increased body mass and marked insulin resistance. Herein, we examined the effects of high carbohydrate intake on cardiac function abnormalities by evaluating in situ heart work, heart rate, and electrocardiograms (ECGs) in rats. MetS was induced in male Wistar rats by adding 32% sucrose to drinking water for 22-24 weeks and was confirmed by insulin resistance, increased body weight, increased blood glucose and serum insulin, and increased systolic and diastolic blood pressures in addition to significant loss of left ventricular integrity and increased connective tissue around myofibrils. Analysis of in situ ECG recordings showed a markedly shortened QT interval and decreased QRS amplitude with increased heart rate. We also observed increased oxidative stress and decreased antioxidant defense characterized by decreases in serum total thiol level and attenuated paraoxonase and arylesterase activities. Our data indicate that increased heart rate and a shortened QT interval concomitant with higher left ventricular developed pressure in response to β-adrenoreceptor stimulation as a result of less cyclic AMP release could be regarded as a natural compensation mechanism in overweight rats with MetS. In addition to the persistent insulin resistance and obesity associated with MetS, one should consider the decreased heart work, increased heart rate, and shortened QT interval associated with high carbohydrate intake, which may have more deleterious effects on the mammalian heart.

  10. gHRV: Heart rate variability analysis made easy.

    Science.gov (United States)

    Rodríguez-Liñares, L; Lado, M J; Vila, X A; Méndez, A J; Cuesta, P

    2014-08-01

    In this paper, the gHRV software tool is presented. It is a simple, free and portable tool developed in python for analysing heart rate variability. It includes a graphical user interface and it can import files in multiple formats, analyse time intervals in the signal, test statistical significance and export the results. This paper also contains, as an example of use, a clinical analysis performed with the gHRV tool, namely to determine whether the heart rate variability indexes change across different stages of sleep. Results from tests completed by researchers who have tried gHRV are also explained: in general the application was positively valued and results reflect a high level of satisfaction. gHRV is in continuous development and new versions will include suggestions made by testers. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Association of heart rate profile during exercise with the severity of coronary artery disease.

    Science.gov (United States)

    Cay, Serkan; Ozturk, Sezgin; Biyikoglu, Funda; Yildiz, Abdulkadir; Cimen, Tolga; Uygur, Belma; Tuna, Funda

    2009-05-01

    Coronary artery disease is the leading cause of morbidity and mortality around the world. Autonomic nervous system abnormalities are associated with coronary artery disease and its complications. Exercise stress tests are routinely used for the detection of the presence of coronary artery disease. In this study, we observed the association between heart rate profile during exercise and the severity of coronary artery disease. One hundred and sixty patients with abnormal exercise treadmill test (> or =1 mm horizontal or downsloping ST-segment depression; 119 men, 41 women; mean age = 57 +/- 9 years) were included in the study. Use of any drug affecting heart rate was not permitted. Resting heart rate before exercise, maximum heart rate during exercise, and resting heart rate after exercise (5 min later) were measured and two parameters were calculated: heart rate increment (maximum heart rate - resting heart rate before exercise) and heart rate decrement (maximum heart rate - resting heart rate after exercise). All patients underwent selective coronary angiography and subclassified into two groups according to stenotic lesion severity. Group 1 had at least 50% of stenotic lesion and group 2 had less than 50%. Patients in the first group had increased resting heart rate, decreased maximum heart rate, decreased heart rate increment, and decreased heart rate decrement compared with second group. All patients were classified into tertiles of resting heart rate, heart rate increment, and heart rate decrement level to evaluate whether these parameters were associated with severity of coronary artery stenosis in the study. The multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 21.888 (95% confidence interval 6.983-68.606) for the highest tertile of resting heart rate level compared with the lowest tertile. In addition, the multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 20.987 (95% confidence interval 6

  12. Heart-rate variability and precompetitive anxiety in swimmers

    OpenAIRE

    Cervantes Blásquez, Julio César

    2009-01-01

    The aim of this study was to test the utility of heart-rate variability (HRV) analyses as a noninvasive means of quantifying cardiac autonomic regulation during precompetitive anxiety situations in swimmers. Psychophysiological state evaluation of 10 volunteer «master» swimmers (6 women and 4 men) was obtained by comparing baseline training condition (TC) with competition condition (CC). Self-evaluation of precompetitive somatic anxiety measured by CSAI-2 showed significant increase from the ...

  13. Assessing Metabolic Syndrome Through Increased Heart Rate During Exercise

    Directory of Open Access Journals (Sweden)

    Masoumeh Sadeghi

    2016-12-01

    Full Text Available The present study aimed to assess changes in resting and maximum heart rates as primary indicators of cardiac autonomic function in metabolic syndrome (MetS patients and to determine their value for discriminating MetS from non-MetS. 468 participants were enrolled in this cross-sectional study and assessed according to the updated adult treatment panel III (ATP-III definition of MetS. Resting and maximum heart rates were recorded following the Bruce protocol during an exercise. A receiver operating characteristic (ROC curve was used to identify the best cutoff point for discriminating MetS from the non-MetS state. 194 participants (41.5% were diagnosed as MetS. The mean resting heart rate (RHR was not statistically different between the two groups (P=0.078. However, the mean maximum heart (MHR rate was considerably higher in participants with MetS (142.37±14.84 beats per min compared to the non-MetS group (134.62±21.63 beats per min (P<0.001. In the MetS group, the MHR was positively correlated with the serum triglyceride level (β=0.185, P=0.033 and was inversely associated with age (β=-0.469, P<0.001. The MHR had a moderate value for discriminating MetS from the non-MetS state (c=0.580, P=0.004 with the optimal cutoff point of 140 beats per min. In MetS patients, the MHR was significantly greater compared to non-MetS subjects and was directly correlated with serum triglyceride levels and inversely with advanced age. Moreover, MHR can be used as a suspicious indicator for identifying MetS.

  14. Assessing Metabolic Syndrome Through Increased Heart Rate During Exercise.

    Science.gov (United States)

    Sadeghi, Masoumeh; Gharipour, Mojgan; Nezafati, Pouya; Shafie, Davood; Aghababaei, Esmaeil; Sarrafzadegan, Nizal

    2016-11-01

    The present study aimed to assess changes in resting and maximum heart rates as primary indicators of cardiac autonomic function in metabolic syndrome (MetS) patients and to determine their value for discriminating MetS from non-MetS. 468 participants were enrolled in this cross-sectional study and assessed according to the updated adult treatment panel III (ATP-III) definition of MetS. Resting and maximum heart rates were recorded following the Bruce protocol during an exercise. A receiver operating characteristic (ROC) curve was used to identify the best cutoff point for discriminating MetS from the non-MetS state. 194 participants (41.5%) were diagnosed as MetS. The mean resting heart rate (RHR) was not statistically different between the two groups (P=0.078). However, the mean maximum heart (MHR) rate was considerably higher in participants with MetS (142.37±14.84 beats per min) compared to the non-MetS group (134.62±21.63 beats per min) (P<0.001). In the MetS group, the MHR was positively correlated with the serum triglyceride level (β=0.185, P=0.033) and was inversely associated with age (β=-0.469, P<0.001). The MHR had a moderate value for discriminating MetS from the non-MetS state (c=0.580, P=0.004) with the optimal cutoff point of 140 beats per min. In MetS patients, the MHR was significantly greater compared to non-MetS subjects and was directly correlated with serum triglyceride levels and inversely with advanced age. Moreover, MHR can be used as a suspicious indicator for identifying MetS.

  15. Heart rate variability: a tool to explore the sleeping brain?

    OpenAIRE

    Chouchou, Florian; Desseilles, Martin

    2014-01-01

    Sleep is divided into two main sleep stages: (1) non-rapid eye movement sleep (non-REMS), characterized among others by reduced global brain activity; and (2) rapid eye movement sleep (REMS), characterized by global brain activity similar to that of wakefulness. Results of heart rate variability (HRV) analysis, which is widely used to explore autonomic modulation, have revealed higher parasympathetic tone during normal non-REMS and a shift toward sympathetic predominance during normal REMS. M...

  16. Evaluation of Stress Parameters Based on Heart Rate Variability Measurements

    OpenAIRE

    Uysal, Fatma; Tokmakçı, Mahmut

    2018-01-01

    In this study, heart rate variabilitymeasurements and analysis was carried with help of the ECG recordings to showhow autonom nervous system activity changes. So as to evaluate the parametersrelated to stress of the study, the situation of relaxation, Stroop color/wordtest, mental test and auditory stimulus that would stress someone out wereapplied to six volunteer participants in a laboratory environment. Being takentotally seven minutes ECG recording and made analysis in time and frequencyd...

  17. Heart Rate Variability and Autonomic Modulations in Preeclampsia.

    Directory of Open Access Journals (Sweden)

    Shaza M Musa

    Full Text Available Although the exact pathophysiology of preeclampsia is not well understood, autonomic nervous system imbalance is suggested as one of the main factors.To investigate heart rate variability (HRV and autonomic modulations in Sudanese pregnant women with preeclampsia.A case-control study (60 women in each arm was conducted at Omdurman Maternity Hospital-Sudan, during the period from June to August, 2014. Cases were women presented with preeclampsia and healthy pregnant women were the controls. Studied groups were matched for important determinants of HRV. Natural logarithm (Ln of total power (TP, high frequency (HF, low frequency (LF and very low frequency (VLF were used to determine HRV. Normalized low and high frequencies (LF Norm and HF Norm were used to evaluate sympathetic and parasympathetic autonomic modulations respectively.Patients with preeclampsia achieved significantly higher LF Norm [49.80 (16.25 vs. 44.55 (19.15, P = 0.044] and LnLF/HF [0.04 (0.68 vs. -0.28 (0.91, P = 0.023] readings, but lower HF Norm [49.08 (15.29 vs. 55.87 (19.56, P = 0.012], compared with healthy pregnant women. Although all other HRV measurements were higher in the patients with preeclampsia compared with the controls, only LnVLF [4.50 (1.19 vs. 4.01 (1.06, P = 0.017] and LnLF [4.01 (1.58 vs. 3.49 (1.23, P = 0.040] reached statistical significance.The study adds further evidence for the dominant cardiac sympathetic modulations on patients with preeclampsia, probably secondary to parasympathetic withdrawal in this group. However, the higher LnVLF and LnLF readings achieved by preeclamptic women compared with the controls are unexpected in the view that augmented sympathetic modulations usually depresses all HRV parameters including these two measures.

  18. Poincare indices for analyzing meditative heart rate signals

    Directory of Open Access Journals (Sweden)

    Atefeh Goshvarpour

    2015-06-01

    Full Text Available Background: Poincare plots are commonly used to study the nonlinear behavior of physiologic signals. The aim of this study is to evaluate the Poincare plot indices of human heart rate signals during meditation. Methods: For this purpose, heart rate time series of eight Chi meditators available in Physionet database were used. Poincare plots with lags of 1 and 6 were constructed, and the ratio of the minor axis to major axis (SD1/SD2 and the area of Poincare plots were calculated for each lag. Results: The results show that the SD1/SD2 ratio increased significantly during meditation compared to that before meditation, especially the index measured from Poincare plots reconstructed with a lag of 6 (p < 0.05. In addition, in both lags, the area of Poincare plots decreased significantly during meditation compared to before meditation (p < 0.05. Conclusion: The comparative dynamic measures of the Poincare plot indices during and before meditation give more insight of the heart rate signals in a specific psychophysiological state.

  19. Heart rate and flow velocity variability as determined from umbilical Doppler velocimetry at 10-20 weeks of gestation.

    Science.gov (United States)

    Ursem, N T; Struijk, P C; Hop, W C; Clark, E B; Keller, B B; Wladimiroff, J W

    1998-11-01

    1. The aim of this study was to define from umbilical artery flow velocity waveforms absolute peak systolic and time-averaged velocity, fetal heart rate, fetal heart rate variability and flow velocity variability, and the relation between fetal heart rate and velocity variables in early pregnancy.2.A total of 108 women presenting with a normal pregnancy from 10 to 20 weeks of gestation consented to participate in a cross-sectional study design. Doppler ultrasound recordings were made from the free-floating loop of the umbilical cord.3. Umbilical artery peak systolic and time-averaged velocity increased at 10-20 weeks, whereas fetal heart rate decreased at 10-15 weeks of gestation and plateaued thereafter. Umbilical artery peak systolic velocity variability and fetal heart rate variability increased at 10-20 and 15-20 weeks respectively.4. The inverse relationship between umbilical artery flow velocity and fetal heart rate at 10-15 weeks of gestation suggests that the Frank-Starling mechanism regulates cardiovascular control as early as the late first and early second trimesters of pregnancy. A different underlying mechanism is suggested for the observed variability profiles in heart rate and umbilical artery peak systolic velocity. It is speculated that heart rate variability is mediated by maturation of the parasympathetic nervous system, whereas peak systolic velocity variability reflects the activation of a haemodynamic feedback mechanism.

  20. [Correlation between resting heart rate and blood glucose level in elderly patients with coronary heart disease and diabetes mellitus].

    Science.gov (United States)

    Liang, Dong-Liang; Li, Xiao-Ying; Wang, Lin; Xu, Hao; Tuo, Xi-Ping; Jian, Zai-Jin; Wang, Xiao-Na; Yun, Ji-Li; Zhang, Xu; Wang, Si-Yue

    2016-05-01

    To explore the correlation between resting heart rate (RHR) and blood glucose level in elderly patients with coronary heart disease (CHD) complicated by diabetes mellitus. Between April and July, 2011, a total of 1336 outpatients over 60 years of age recruited from 165 hospitals were asked to complete a questionnaire and received blood glucose and RHR examination. According to baseline RHR, the patients were divided into 3 groups with HRH blood glucose control rate. HbA1c levels in the total, male and female patients differed significantly among the 3 groups (F=15.436, 15.436, and 24.270, respectively, PBlood glucose control rate in the total, male and female patients also differed significantly among the 3 groups (χ(2)=13.471, 6.752, and 6.522, respectively, Pblood glucose control failure of 1.99 (95% CI: 1.23-2.37, Pblood glucose level, and an increased RHR is associated with an increased risk of poor blood glucose control. Rigorous RHR control in such high-risk patients may prove beneficial for both blood glucose control and secondary prevention of CHD.

  1. Social network diversity and risks of ischemic heart disease and total mortality: findings from the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Barefoot, JC; Grønbæk, M; Jensen, Gorm Boje

    2005-01-01

    Measures of various types of social contacts were used as predictors of ischemic heart disease events and total mortality in an age-stratified random sample of 9,573 adults enrolled in the Copenhagen City Heart Study (Copenhagen, Denmark). Baseline examinations were conducted in 1991-1994, and pa......Measures of various types of social contacts were used as predictors of ischemic heart disease events and total mortality in an age-stratified random sample of 9,573 adults enrolled in the Copenhagen City Heart Study (Copenhagen, Denmark). Baseline examinations were conducted in 1991......-1994, and participants were followed until the end of 1997. Contacts with parents, children, family members, and friends were associated with better health. The presence of a spouse or partner was protective for men. Contacts with neighbors showed a trend toward a reversed pattern, and the effects of contacts with work...... colleagues and children differed by gender. Most types of contacts that occurred at least monthly were just as protective as those occurring more frequently. An index of intimate social contact diversity with family and friends had graded relations with both outcomes. Comparisons of persons reporting three...

  2. Effects of metronome breathing on the assessment of autonomic control using heart rate variability

    NARCIS (Netherlands)

    Haaksma, J; Brouwer, J; vandenBerg, MP; Dijk, WA; Dassen, WRM; Crijns, HJGM; Mulder, Lambertus; Mulder, Gysbertus

    1996-01-01

    Analysis of Heart Rate Variability is a non-invasive quantitative tool to study the influence of the autonomic nervous system on the heart. Rapid variations in heart rate, related to breathing are primarily mediated by the vagal limb of the autonomic nervous system. The resulting variations in heart

  3. Past and Present of Total Artificial Heart Therapy: A Success Story

    Science.gov (United States)

    Samak, Mostafa; Fatullayev, Javid; Sabashnikov, Anton; Zeriouh, Mohamed; Rahmanian, Parwis B.; Choi, Yeong-Hoon; Wippermann, Jens; Wahlers, Thorsten; Schmack, Bastian; Ruhparwar, Arjang; Dohmen, Pascal M.; Karck, Matthias; Popov, Aron-Frederik; Simon, André R.; Weymann, Alexander

    2015-01-01

    The totally artificial heart (TAH) is among the most prominent medical innovations of the 21st century, especially due to the increasing population with end-stage heart failure. The progressive course of the disease, its resistance to conventional therapy, and the scarcity of hearts available for transplantation were the prime impetus for developing a TAH, especially when other options of mechanical circulatory assist devices are exhausted. In this review, we narrate the history of TAH, give an overview of its technology, and address the pros and cons of the currently available TAH models in light of published clinical experience. PMID:26343363

  4. Past and Present of Total Artificial Heart Therapy: A Success Story.

    Science.gov (United States)

    Samak, Mostafa; Fatullayev, Javid; Sabashnikov, Anton; Zeriouh, Mohamed; Rahmanian, Parwis B; Choi, Yeong-Hoon; Wippermann, Jens; Wahlers, Thorsten; Schmack, Bastian; Ruhparwar, Arjang; Dohmen, Pascal M; Karck, Matthias; Popov, Aron-Frederik; Simon, André R; Weymann, Alexander

    2015-09-07

    The totally artificial heart (TAH) is among the most prominent medical innovations of the 21st century, especially due to the increasing population with end-stage heart failure. The progressive course of the disease, its resistance to conventional therapy, and the scarcity of hearts available for transplantation were the prime impetus for developing a TAH, especially when other options of mechanical circulatory assist devices are exhausted. In this review, we narrate the history of TAH, give an overview of its technology, and address the pros and cons of the currently available TAH models in light of published clinical experience.

  5. Relationship between exercise heart rate and music tempo preference

    OpenAIRE

    Karageorghis, CI; Jones, L; Low, DC

    2006-01-01

    The present study examined the predicted positive and linear relationship (Iwanaga, 1995a,1995b) between exercise heart rate and music tempo preference. Initially, 128 undergraduates (M 3 age = 20.0 years, SD = 0.9 years) were surveyed to establish their three favorite music artists of all time. A separate experimental group of 29 undergraduates (M age = 20.3 years, SD = 1.2 years) selected the music of a single artist from a choice of the three highest-rated artists from the earlier survey. ...

  6. Prolonged heart xenograft survival using combined total lymphoid irradiation and cyclosporine

    International Nuclear Information System (INIS)

    Knechtle, S.J.; Halperin, E.C.; Saad, T.; Bollinger, R.R.

    1986-01-01

    Total lymphoid irradiation and cyclosporine have profound immunosuppressive properties and permit successful heart allotransplantation. Cyclosporine used alone has not permitted consistently successful transplantation between species in all cases. Total lymphoid irradiation has not been applied to xenotransplantation. The efficacy of total lymphoid irradiation alone and in combination with cyclosporine was examined using an animal model of heart xenotransplantation. Heterotopic heart transplants were performed using inbred Syrian hamsters as donors and Lewis rats as recipients. Total lymphoid irradiation was administered preoperatively over 3 weeks for a total dose of 15 gray. Cyclosporine was started on the day of surgery and was given as a daily intramuscular injection of 2.5, 5, or 10 mg/kg/day until rejection was complete. Neither total lymphoid irradiation nor cyclosporine alone markedly prolonged graft survival. However, combined total lymphoid irradiation and cyclosporine, 5 or 10 mg/kg/day, dramatically prolonged graft survival to greater than 100 days in most recipients. There were no treatment-related deaths. In conclusion, combined total lymphoid irradiation and cyclosporine permit successful long-term survival of heart xenotransplants in this hamster-to-rat model

  7. Assessment of post-laparotomy pain in laboratory mice by telemetric recording of heart rate and heart rate variability

    Science.gov (United States)

    Arras, Margarete; Rettich, Andreas; Cinelli, Paolo; Kasermann, Hans P; Burki, Kurt

    2007-01-01

    Background Pain of mild to moderate grade is difficult to detect in laboratory mice because mice are prey animals that attempt to elude predators or man by hiding signs of weakness, injury or pain. In this study, we investigated the use of telemetry to identify indicators of mild-to-moderate post-laparotomy pain. Results Adult mice were subjected to laparotomy, either combined with pain treatment (carprofen or flunixin, 5 mg/kg s/c bid, for 1 day) or without pain relief. Controls received anesthesia and analgesics or vehicle only. Telemetrically measured locomotor activity was undisturbed in all animals, thus confirming that any pain experienced was of the intended mild level. No symptoms of pain were registered in any of the groups by scoring the animals' outer appearance or spontaneous and provoked behavior. In contrast, the group receiving no analgesic treatment after laparotomy demonstrated significant changes in telemetry electrocardiogram recordings: increased heart rate and decreased heart rate variability parameters pointed to sympathetic activation and pain lasting for 24 hours. In addition, core body temperature was elevated. Body weight and food intake were reduced for 3 and 2 days, respectively. Moreover, unstructured cage territory and destroyed nests appeared for 1–2 days in an increased number of animals in this group only. In controls these parameters were not affected. Conclusion In conclusion, real-time telemetric recordings of heart rate and heart rate variability were indicative of mild-to-moderate post-laparotomy pain and could define its duration in our mouse model. This level of pain cannot easily be detected by direct observation. PMID:17683523

  8. Assessment of post-laparotomy pain in laboratory mice by telemetric recording of heart rate and heart rate variability

    Directory of Open Access Journals (Sweden)

    Kasermann Hans P

    2007-08-01

    Full Text Available Abstract Background Pain of mild to moderate grade is difficult to detect in laboratory mice because mice are prey animals that attempt to elude predators or man by hiding signs of weakness, injury or pain. In this study, we investigated the use of telemetry to identify indicators of mild-to-moderate post-laparotomy pain. Results Adult mice were subjected to laparotomy, either combined with pain treatment (carprofen or flunixin, 5 mg/kg s/c bid, for 1 day or without pain relief. Controls received anesthesia and analgesics or vehicle only. Telemetrically measured locomotor activity was undisturbed in all animals, thus confirming that any pain experienced was of the intended mild level. No symptoms of pain were registered in any of the groups by scoring the animals' outer appearance or spontaneous and provoked behavior. In contrast, the group receiving no analgesic treatment after laparotomy demonstrated significant changes in telemetry electrocardiogram recordings: increased heart rate and decreased heart rate variability parameters pointed to sympathetic activation and pain lasting for 24 hours. In addition, core body temperature was elevated. Body weight and food intake were reduced for 3 and 2 days, respectively. Moreover, unstructured cage territory and destroyed nests appeared for 1–2 days in an increased number of animals in this group only. In controls these parameters were not affected. Conclusion In conclusion, real-time telemetric recordings of heart rate and heart rate variability were indicative of mild-to-moderate post-laparotomy pain and could define its duration in our mouse model. This level of pain cannot easily be detected by direct observation.

  9. Heart rate turbulence and variability in patients with ventricular arrhythmias

    Directory of Open Access Journals (Sweden)

    Diego Tarricone

    2009-08-01

    Full Text Available Background: To evaluate the changes in autonomic neural control mechanisms before malignant ventricular arrhythmias, we measured heart rate variability (HRV and heart rate turbulence (HRT in patients with ventricular tachycardia or fibrillation (Group I; n=6, non sustained ventricular tachycardia (Group II; n=32, frequent premature ventricular beats (Group III; n=26 and with ICD implantation (Group IV; n=11. Methods: Time domain parameters of HRV and turbulence onset (TO and slope (TS were calculated on 24 hour Holter recordings. Normal values were: SDNN > 70 msec for HRV, TO <0% and TS >2.5 msec/RR-I for HRT. Results: Whereas SDNN was within normal range and similar in all study groups, HRT parameters were significantly different in patients who experienced VT/VF during Holter recording. Abnormal TO and/or TS were present in 100% of Group I patients and only in about 50% of Group II and IV. On the contrary, normal HRT parameters were present in 40-70% of Group II, III and IV patients and none of Group I. Conclusions: These data suggest that HRT analysis is more suitable than HRV to detect those transient alterations in autonomic control mechanisms that are likely to play a major trigger role in the genesis of malignant cardiac arrhythmias. (Heart International 2007; 3: 51-7

  10. Heart rate variability changes in physicians working on night call.

    Science.gov (United States)

    Malmberg, Birgitta; Persson, Roger; Flisberg, Per; Ørbaek, Palle

    2011-03-01

    Adverse effects by night-call duty have become an important occupational health issue. The aim of this study was to investigate whether the heart rate variability (HRV) differed during recovery from day work and night-call duty between distinct physician specialities. We studied the impact of a 16-h night-call duty on autonomic balance, measured by HRV, among two physician groups differing with respect to having to deal with life-threatening conditions while on call. Nineteen anaesthesiologists (ANEST) and 16 paediatricians and ear, nose and throat surgeons (PENT) were monitored by ambulatory digital Holter electrocardiogram (ECG). Heart rate variability was analysed between 21:00 and 22:00 after an ordinary workday, on night call and in the evening post-call. Absolute and normalized high-frequency power (HF, HFnu) were the main outcome variables, expressing parasympathetic influence on the heart. ANEST had lower HF power than PENT while on night call and post-daytime work (p work compared with post-night-call duty (p balance and did not differ between specialities. However, the less dynamic HRV after daytime work and during night-call duty in the ANEST group may indicate a higher physiological stress level. These results may contribute to the improvement of night-call schedules within the health care sector.

  11. Ivabradine in acute coronary syndromes: Protection beyond heart rate lowering.

    Science.gov (United States)

    Niccoli, Giampaolo; Borovac, Josip Anđelo; Vetrugno, Vincenzo; Camici, Paolo G; Crea, Filippo

    2017-06-01

    Ivabradine is a heart rate reducing agent that exhibits anti-ischemic effects through the inhibition of funny electrical current in the sinus node resulting in heart rate reduction, thus enabling longer diastolic perfusion time, and reduced myocardial oxygen consumption without detrimental changes in arterial blood pressure, coronary vasomotion, and ventricular contractility. The current guideline-based clinical use of Ivabradine is reserved for patients with stable angina pectoris who cannot tolerate or whose symptoms are inadequately controlled with beta blockers. In patients with chronic heart failure and reduced ejection fraction, Ivabradine has demonstrated beneficial effects in improving clinical outcomes when added to conventional therapy. However, the role of Ivabradine in acute coronary syndromes has not been established. Based on the results from some relevant preclinical studies and a limited amount of clinical data that were reported recently, the role of Ivabradine in acute ischemic events warrants further investigation. The aim of this review is to provide an overview of the available literature on the potential role of Ivabradine in the clinical context of acute coronary syndromes. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. An Analysis of Total Lightning Flash Rates Over Florida

    Science.gov (United States)

    Mazzetti, Thomas O.; Fuelberg, Henry E.

    2017-12-01

    Although Florida is known as the "Sunshine State", it also contains the greatest lightning flash densities in the United States. Flash density has received considerable attention in the literature, but lightning flash rate has received much less attention. We use data from the Earth Networks Total Lightning Network (ENTLN) to produce a 5 year (2010-2014) set of statistics regarding total flash rates over Florida and adjacent regions. Instead of tracking individual storms, we superimpose a 0.2° × 0.2° grid over the study region and count both cloud-to-ground (CG) and in-cloud (IC) flashes over 5 min intervals. Results show that the distribution of total flash rates is highly skewed toward small values, whereas the greatest rate is 185 flashes min-1. Greatest average annual flash rates ( 3 flashes min-1) are located near Orlando. The southernmost peninsula, North Florida, and the Florida Panhandle exhibit smaller average annual flash rates ( 1.5 flashes min-1). Large flash rates > 100 flashes min-1 can occur during any season, at any time during the 24 h period, and at any location within the domain. However, they are most likely during the afternoon and early evening in East Central Florida during the spring and summer months.

  13. Heart rate variability alters cardiac repolarization and electromechanical dynamics.

    Science.gov (United States)

    Phadumdeo, Vrishti M; Weinberg, Seth H

    2018-04-07

    Heart rate continuously varies due to autonomic regulation, stochasticity in pacemaking, and circadian rhythm, collectively termed heart rate variability (HRV), during normal physiological conditions. Low HRV is clinically associated with an elevated risk of cardiac arrhythmias. Alternans, a beat-to-beat alternation in action potential duration (APD) and/or intracellular calcium (Ca) transient, is a well-known risk factor associated with cardiac arrhythmias that is typically studied under conditions of a constant pacing rate, i.e., the absence of HRV. In this study, we investigate the effects of HRV on the interplay between APD, Ca, and electromechanical properties, employing a nonlinear discrete-time map model that governs APD and intracellular Ca cycling with a stochastic pacing period. We find that HRV can decrease variation in APD and peak Ca at fast pacing rates for which alternans is present. Further, increased HRV typically disrupts the alternating pattern for both APD and peak Ca and weakens the correlation between APD and peak Ca, thus decoupling Ca-mediated instabilities from repolarization alternation. We find that the efficacy of these effects is regulated by the sarcoplasmic reticulum Ca uptake rate. Overall, these results demonstrate that HRV disrupts arrhythmogenic alternans and suggests that HRV may be a significant factor in preventing life-threatening arrhythmias. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Heart rate variability analysis in healthy subjects, patients suffering from congestive heart failure and heart transplanted patients

    Directory of Open Access Journals (Sweden)

    Argentina Leite

    2013-12-01

    Full Text Available This study aimed to find parameters to characterize heart rate variability (HRV and discriminate healthy subjects and patients with heart diseases. The parameters used for discrimination characterize the different components of HRV memory (short and long and are extracted from HRV recordings using parametric as well as non parametric methods. Thus, the parameters are: spectral components at low frequencies (LH and high frequencies (HF which are associated with the short memory of HRV and the long memory parameter (d obtained from autoregressive fractionally integrated moving average (ARFIMA models. In the non parametric context, short memory (α1 and long memory (α2 parameters are obtained from detrended fluctuation analysis (DFA. The sample used in this study contains 24-hour Holter HRV recordings of 30 subjects: 10 healthy individuals, 10 patients suffering from congestive heart failure and 10 heart transplanted patients from the Noltisalis database. It was found that short memory parameters present higher values for the healthy individuals whereas long memory parameters present higher values for the diseased individuals. Moreover, there is evidence that ARFIMA modeling allows the discrimination between the 3 groups under study, being advantageous over DFA.

  15. Heart rate responses to autonomic challenges in obstructive sleep apnea.

    Directory of Open Access Journals (Sweden)

    Paul M Macey

    Full Text Available Obstructive sleep apnea (OSA is accompanied by structural alterations and dysfunction in central autonomic regulatory regions, which may impair dynamic and static cardiovascular regulation, and contribute to other syndrome pathologies. Characterizing cardiovascular responses to autonomic challenges may provide insights into central nervous system impairments, including contributions by sex, since structural alterations are enhanced in OSA females over males. The objective was to assess heart rate responses in OSA versus healthy control subjects to autonomic challenges, and, separately, characterize female and male patterns. We studied 94 subjects, including 37 newly-diagnosed, untreated OSA patients (6 female, age mean ± std: 52.1 ± 8.1 years; 31 male aged 54.3 ± 8.4 years, and 57 healthy control subjects (20 female, 50.5 ± 8.1 years; 37 male, 45.6 ± 9.2 years. We measured instantaneous heart rate with pulse oximetry during cold pressor, hand grip, and Valsalva maneuver challenges. All challenges elicited significant heart rate differences between OSA and control groups during and after challenges (repeated measures ANOVA, p<0.05. In post-hoc analyses, OSA females showed greater impairments than OSA males, which included: for cold pressor, lower initial increase (OSA vs. control: 9.5 vs. 7.3 bpm in females, 7.6 vs. 3.7 bpm in males, OSA delay to initial peak (2.5 s females/0.9 s males, slower mid-challenge rate-of-increase (OSA vs. control: -0.11 vs. 0.09 bpm/s in females, 0.03 vs. 0.06 bpm/s in males; for hand grip, lower initial peak (OSA vs. control: 2.6 vs. 4.6 bpm in females, 5.3 vs. 6.0 bpm in males; for Valsalva maneuver, lower Valsalva ratio (OSA vs. control: 1.14 vs. 1.30 in females, 1.29 vs. 1.34 in males, and OSA delay during phase II (0.68 s females/1.31 s males. Heart rate responses showed lower amplitude, delayed onset, and slower rate changes in OSA patients over healthy controls, and impairments may be more pronounced in

  16. Electron-beam CT coronary angiography in the patients with high heart rate arrhythmia or pacemaker

    International Nuclear Information System (INIS)

    Dong Zhi; Zhu Jiemin; Liu Zhe; Liu Junbo; Li Youjie; Qi Ji

    2006-01-01

    Objective: To report the clinical applicability of coronary angiography for patients with high heart rate, arrhythmia or cardiac pacing using the new-generation of electron-beam CT (e-Speed). Methods: EBCT (GE e-Speed) coronary angiography was performed in 36 eases (male 27, female 9, mean age 58), including the heart rate more than 90 bpm in 20 patients, frequent ectopic beats in 11 cases, implantation of cardiac pacemaker in 4 patients and the unacceptable MSCT image quality due to variability of interscan heart rate (from 82 bpm to 104 bpm) in 1 case. After volume data set was acquired using spiral mode with prospective ECG-gating, the reconstructions of MIP, CPR, VR and Cine were performed. The VR quality was evaluated using a five-point scale. Results: The quality of coronary imaging in all of 36 cases were acceptable. The total visualization rate of coronary artery branches was 80.0%. Left main, left anterior artery and right coronary artery were visualized in all patients and in 94.3% of all cases circumflex artery were visible. Conclusion: EBCT (e-Speed) is applicable in noninvasive coronary angiography for patients with high heart rate, arrhythmia or implanted cardiac pacemaker', and this examination can obtain satisfied diagnosis. (authors)

  17. Small-volume amnioinfusion: a potential stimulus of intrapartum fetal heart rate accelerations.

    Science.gov (United States)

    Wax, Joseph R; Flaherty, Nina; Pinette, Michael G; Blackstone, Jacquelyn; Cartin, Angelina

    2004-02-01

    We describe a recurrent nonreassuring fetal heart rate pattern in which small-volume amnioinfusions apparently evoked fetal heart rate accelerations suggested fetal well-being, allowing that progressive labor that culminated in the vaginal delivery of a healthy infant.

  18. Using a smartphone to measure heart rate changes during relived happiness and anger

    NARCIS (Netherlands)

    Lakens, D.

    2013-01-01

    This study demonstrates the feasibility of measuring heart rate differences associated with emotional states such as anger and happiness with a smartphone. Novice experimenters measured higher heart rates during relived anger and happiness (replicating findings in the literature) outside a

  19. Adaptive Mean and Trend Removal of Heart Rate Variability Using Kalman Filtering

    National Research Council Canada - National Science Library

    Schloegl, A

    2001-01-01

    Analysis of heart rate van ability requires the calculation of the mean heart rate, Adaptive methods are important for online and real-time parameter estimation, In this paper we demonstrate the use...

  20. Omega-3 Polyunsaturated Fatty Acids and Heart Rate Variability

    Directory of Open Access Journals (Sweden)

    Jeppe Hagstrup Christensen

    2011-11-01

    Full Text Available Omega-3 polyunsaturated fatty acids (PUFA may modulate autonomic control of the heart because omega-3 PUFA is abundant in the brain and other nervous tissue as well as in cardiac tissue. This might partly explain why omega-3 PUFA offer some protection against sudden cardiac death (SCD. The autonomic nervous system is involved in the pathogenesis of SCD. Heart rate variability (HRV can be used as a non-invasive marker of cardiac autonomic control and a low HRV is a predictor for SCD and arrhythmic events. Studies on HRV and omega-3 PUFA have been performed in several populations such as patients with ischemic heart disease, patients with diabetes mellitus, patients with chronic renal failure, and in healthy subjects as well as in children.. The studies have demonstrated a positive association between cellular content of omega-3 PUFA and HRV and supplementation with omega-3 PUFA seems to increase HRV which could be a possible explanation for decreased risk of arrhythmic events and SCD sometimes observed after omega-3 PUFA supplementation. However, the results are not consistent and further research is needed

  1. [Heart rate variability and physical exercise. Current status].

    Science.gov (United States)

    Hottenrott, Kuno; Hoos, Olaf; Esperer, Hans Dieter

    2006-09-01

    Heart rate variability (HRV) has long been used in risk stratification for sudden cardiac death and diabetic autonomic neuropathy. In recent years, both time and frequency domain indices of HRV also gained increasing interest in sports and training sciences. In these fields, HRV is currently used for the noninvasive assessment of autonomic changes associated with short-term and long-term endurance exercise training in both leisure sports activity and high-performance training. Furthermore, HRV is being investigated as a diagnostic marker of overreaching and overtraining.A large body of evidence shows that, in healthy subjects and cardiovascular patients of all ages (up to an age of 70 years), regular aerobic training usually results in a significant improvement of overall as well as instantaneous HRV. These changes, which are accompanied by significant reductions in heart rates both at rest and during submaximal exercise, reflect an increase in autonomic efferent activity and a shift in favor of enhanced vagal modulation of the cardiac rhythm. Regular aerobic training of moderate volume and intensity over a minimum period of 3 months seems to be necessary to ensure these effects, which might be associated with a prognostic benefit regarding overall mortality.At present, available data does not allow for final conclusions with respect to the usefulness of traditional HRV indices in assessing an individual's exercise performance and monitoring training load. The discrepant results published so far are due to several factors including insufficient study size and design, and different HRV methods. Large-sized and prospectively designed studies are necessary for clarification. It also remains to be seen, whether the traditional HRV indices prove useful in the diagnosis of overreaching and overtraining. Preliminary results, though promising, need to be confirmed in larger cohorts.A basic problem in HRV analysis is nonstationarity of the heart rate signal, which holds

  2. Improved detection of congestive heart failure via probabilistic symbolic pattern recognition and heart rate variability metrics.

    Science.gov (United States)

    Mahajan, Ruhi; Viangteeravat, Teeradache; Akbilgic, Oguz

    2017-12-01

    A timely diagnosis of congestive heart failure (CHF) is crucial to evade a life-threatening event. This paper presents a novel probabilistic symbol pattern recognition (PSPR) approach to detect CHF in subjects from their cardiac interbeat (R-R) intervals. PSPR discretizes each continuous R-R interval time series by mapping them onto an eight-symbol alphabet and then models the pattern transition behavior in the symbolic representation of the series. The PSPR-based analysis of the discretized series from 107 subjects (69 normal and 38 CHF subjects) yielded discernible features to distinguish normal subjects and subjects with CHF. In addition to PSPR features, we also extracted features using the time-domain heart rate variability measures such as average and standard deviation of R-R intervals. An ensemble of bagged decision trees was used to classify two groups resulting in a five-fold cross-validation accuracy, specificity, and sensitivity of 98.1%, 100%, and 94.7%, respectively. However, a 20% holdout validation yielded an accuracy, specificity, and sensitivity of 99.5%, 100%, and 98.57%, respectively. Results from this study suggest that features obtained with the combination of PSPR and long-term heart rate variability measures can be used in developing automated CHF diagnosis tools. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Relationship between exercise heart rate and music tempo preference.

    Science.gov (United States)

    Karageorghis, Costas I; Jones, Leighton; Low, Daniel C

    2006-06-01

    The present study examined the predicted positive and linear relationship (Iwanaga, 1995a, 1995b) between exercise heart rate and music tempo preference. Initially, 128 undergraduate students (M age = 20.0 years, SD = 0.9) were surveyed to establish their three favorite music artists. A separate experimental group of 29 undergraduates (M age = 20.3 years, SD = 1.2) selected the music of a single artist from the three highest-rated artists from the earlier survey. They reported their preference for slow, medium, and fast tempo selections from each artist for three treadmill walking conditions at 40%, 60%, and 75% maximal heart rate reserve. A mixed-model 3 x 3 x 2 (Exercise Intensity x Music Tempo x Gender) analysis of variance was used to analyze the data. Results indicated there was no three-way interaction for music preference. There was, however, a significant (p Music Tempo (partial eta2 = .09) and a significant (p effect for music tempo, with large differences evident between preference for medium versus slow tempo and fast versus slow tempo music at all exercise intensities (partial eta2 = .78). Participants reported a preference for both medium and fast tempo music at low and moderate exercise intensities and for fast tempo music at high intensity. Only partial support was found for the expected linear relationship between exercise intensity and music tempo preference.

  4. Correlated and uncorrelated heart rate fluctuations during relaxing visualization

    Science.gov (United States)

    Papasimakis, N.; Pallikari, F.

    2010-05-01

    The heart rate variability (HRV) of healthy subjects practicing relaxing visualization is studied by use of three multiscale analysis techniques: the detrended fluctuation analysis (DFA), the entropy in natural time (ENT) and the average wavelet (AWC) coefficient. The scaling exponent of normal interbeat interval increments exhibits characteristics of the presence of long-range correlations. During relaxing visualization the HRV dynamics change in the sense that two new features emerge independent of each other: a respiration-induced periodicity that often dominates the HRV at short scales (sleep.

  5. Heart rate variability among caregivers of chronically bedridden patients

    Directory of Open Access Journals (Sweden)

    Amrith Pakkala

    2013-01-01

    Full Text Available Background: Caregivers of chronically bedridden patients are likely to suffer from mental and physical exhaustion leading to stress. This is important in view of the prevailing socioeconomic as well as the healthcare system available in a developing country like India. Therefore, the present study is designed to measure heart rate variability (HRV among this special group of population who give care to long-term bedridden patients. Materials and Methods: Fifteen female subjects were enrolled from among attendants of patients admitted with an immediate history of a cerebrovascular accident with locomotor deficits, who required constant care. They were free from any type of physical and mental health issues, nonsmokers and nonaddicts. Each care giver was subjected to HRV analysis on three occasions: The first record was performed in the 1 st week of their arrival in the hospital as caregivers. The second observation was recorded after 3 months of caregiving. The final HRV analysis was done after 6 months of care giving. Two types of parameters were analyzed: Time domain and frequency domain. Statistical analysis was done using paired t-test. Results: Both the HRV parameters: Time and frequency domain, showed decreased values during the 3 rd and 6 th month recording as compared to the 1 st week recording. The decrease is much more during the 6 th month recording as compared to the 3 rd month recording. Statistically significant decrease is observed in mean RR interval, heart rate, very low frequency (VLF, and LF only when the 1 st week recording is compared with the 3 rd month recording, but when the 1 st week recording was compared with the 6 th month recording significant decrease was found in mean RR interval and heart rate. Conclusion: Subjects involved in taking care of chronically ill bedridden patients are likely to undergo a lot of physical and mental stress, thus affecting their autonomic status. HRV analysis using short term

  6. Heart rate variability biofeedback: how and why does it work?

    Science.gov (United States)

    Lehrer, Paul M.; Gevirtz, Richard

    2014-01-01

    In recent years there has been substantial support for heart rate variability biofeedback (HRVB) as a treatment for a variety of disorders and for performance enhancement (Gevirtz, 2013). Since conditions as widely varied as asthma and depression seem to respond to this form of cardiorespiratory feedback training, the issue of possible mechanisms becomes more salient. The most supported possible mechanism is the strengthening of homeostasis in the baroreceptor (Vaschillo et al., 2002; Lehrer et al., 2003). Recently, the effect on the vagal afferent pathway to the frontal cortical areas has been proposed. In this article, we review these and other possible mechanisms that might explain the positive effects of HRVB. PMID:25101026

  7. Heart rate variability biofeedback: How and why does it work?

    Directory of Open Access Journals (Sweden)

    Paul M Lehrer

    2014-07-01

    Full Text Available In recent years there has been substantial support for Heart Rate Variability Biofeedback (HRVB as a treatment for a variety of disorders and for performance enhancement (Gevirtz, 2013. Since conditions as widely varied as asthma and depression seem to respond to this form of cardiorespiratory feedback training, the issue of possible mechanisms becomes more salient. The most supported possible mechanism is the strengthening of homeostasis in the barorecptor (Vashillo, et al, 2002; Lehrer, et al, 2003. Recently, the effect on the vagal afferent pathway to the frontal cortical areas has been proposed. In this article, we review these and other possible mechanisms that might explain the positive effects of HRVB.

  8. Entertainment Capture through Heart Rate Activity in Physical Interactive Playgrounds

    DEFF Research Database (Denmark)

    Yannakakis, Georgios; Hallam, John; Lund, Henrik Hautop

    2008-01-01

    children’s physiological signals, an estimator of the degree to which games provided by the playground engage the players. For this purpose children’s heart rate (HR) signals, and their expressed preferences of how much “fun” particular game variants are, are obtained from experiments using games...... that predict reported entertainment preferences given HR features. These models are expressed as artificial neural networks and are demonstrated and evaluated on two Playware games and two control tasks requiring physical activity. The best network is able to correctly match expressed preferences in 64...

  9. Attenuated heart rate response is associated with hypocretin deficiency in patients with narcolepsy.

    Science.gov (United States)

    Sorensen, Gertrud Laura; Knudsen, Stine; Petersen, Eva Rosa; Kempfner, Jacob; Gammeltoft, Steen; Sorensen, Helge Bjarup Dissing; Jennum, Poul

    2013-01-01

    Several studies have suggested that hypocretin-1 may influence the cerebral control of the cardiovascular system. We analyzed whether hypocretin-1 deficiency in narcolepsy patients may result in a reduced heart rate response. We analyzed the heart rate response during various sleep stages from a 1-night polysomnography in patients with narcolepsy and healthy controls. The narcolepsy group was subdivided by the presence of +/- cataplexy and +/- hypocretin-1 deficiency. Sleep laboratory studies conducted from 2001-2011. In total 67 narcolepsy patients and 22 control subjects were included in the study. Cataplexy was present in 46 patients and hypocretin-1 deficiency in 38 patients. None. All patients with narcolepsy had a significantly reduced heart rate response associated with arousals and leg movements (P hypocretin-1 deficiency and cataplexy groups compared with patients with normal hypocretin-1 levels (P hypocretin-1 deficiency significantly predicted the heart rate response associated with arousals in both REM and non-REM in a multivariate linear regression. Our results show that autonomic dysfunction is part of the narcoleptic phenotype, and that hypocretin-1 deficiency is the primary predictor of this dysfunction. This finding suggests that the hypocretin system participates in the modulation of cardiovascular function at rest.

  10. Bilateral hegu acupoints have the same effect on the heart rate variability of the healthy subjects.

    Science.gov (United States)

    Guangjun, Wang; Yuying, Tian; Shuyong, Jia; Wenting, Zhou; Weibo, Zhang

    2014-01-01

    Background. The specificity of acupuncture points (acupoints) is one of the key concepts in traditional acupuncture theory, but the question of whether there is adequate scientific evidence to prove or disprove specificity has been vigorously debated in recent years. Acupoint laterality is an important aspect of acupoint specificity. Data is particularly scarce regarding the laterality of the same channel, namesake acupoint located on opposite sides of the body. Our previous study results suggest that Neiguan acupoint (PC6) has the laterality. The aim of this study was to investigate whether Hegu (LI4) also has laterality from the perspective of heart rate variability. Methods. A total of twenty-eight healthy female volunteers were recruited for this study and were randomly separated into the group I (n = 14) and the group II (n = 14) according to the register order. In the group I, left LI4 was stimulated in the first epoch and the right LI4 was stimulated in the second epoch. In the group II, right LI4 was stimulated in the first epoch and left LI4 was stimulated in the second epoch. Electrocardiogram was recorded and heart rate variability was analyzed. Results. The results show that there were no significant differences of heart rate variablity between the group I and the group II in the time domain and in the frequency domain. Conclusions. Bilateral Hegu acupoints have the same effect on the heart rate variability of the healthy subjects.

  11. Bilateral Hegu Acupoints Have the Same Effect on the Heart Rate Variability of the Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Wang Guangjun

    2014-01-01

    Full Text Available Background. The specificity of acupuncture points (acupoints is one of the key concepts in traditional acupuncture theory, but the question of whether there is adequate scientific evidence to prove or disprove specificity has been vigorously debated in recent years. Acupoint laterality is an important aspect of acupoint specificity. Data is particularly scarce regarding the laterality of the same channel, namesake acupoint located on opposite sides of the body. Our previous study results suggest that Neiguan acupoint (PC6 has the laterality. The aim of this study was to investigate whether Hegu (LI4 also has laterality from the perspective of heart rate variability. Methods. A total of twenty-eight healthy female volunteers were recruited for this study and were randomly separated into the group I (n=14 and the group II (n=14 according to the register order. In the group I, left LI4 was stimulated in the first epoch and the right LI4 was stimulated in the second epoch. In the group II, right LI4 was stimulated in the first epoch and left LI4 was stimulated in the second epoch. Electrocardiogram was recorded and heart rate variability was analyzed. Results. The results show that there were no significant differences of heart rate variablity between the group I and the group II in the time domain and in the frequency domain. Conclusions. Bilateral Hegu acupoints have the same effect on the heart rate variability of the healthy subjects.

  12. Impact of space weather on human heart rate during the years 2011-2013

    Science.gov (United States)

    Galata, E.; Ioannidou, S.; Papailiou, M.; Mavromichalaki, H.; Paravolidakis, K.; Kouremeti, M.; Rentifis, L.; Simantirakis, E.; Trachanas, K.

    2017-08-01

    During the last years a possible link between different levels of solar and geomagnetic disturbances and human physiological parameters is suggested by several published studies. In this work the examination of the potential association between heart rate variations and specific space weather activities was performed. A total of 482 individuals treated at Hippocratio General Hospital in Athens, the Cardiology clinics of Nikaia General Hospital in Piraeus and the Heraklion University Hospital in Crete, Greece, were assessed from July 2011 to April 2013. The heart rate of the individuals was recorded by a Holter monitor on a n hourly basis, while the hourly variations of the cosmic ray intensity measured by the Neutron Monitor Station of the Athens University and of the geomagnetic index Dst provided by the Kyoto Observatory were used. The ANalysis Of VAriance (ANOVA) and the Multiple Linear Regression analysis were used for analysis of these data. A statistically significant effect of both cosmic rays and geomagnetic activity on heart rate was observed, which may indicate that changes in space weather could be linked to heart rate variations.

  13. Heart rate variability in infants with West syndrome

    DEFF Research Database (Denmark)

    Møller, Michelle Mai; Høgenhaven, Hans; Uldall, Peter

    2015-01-01

    -Whitney's U-Test) in the awake state, indicating an abnormal autonomic output to the heart. Comparing the initial to the final examination demonstrated a significant increase in the HRV parameters SDNN (31.3ms) and total power (757ms(2); p=0.001 and p=0.013, Wilcoxon Signed Ranked Test). In addition......, when hypsarrhythmia was no longer present. RESULTS: Compared to controls, patients with WS during hypsarrhythmia had significantly lower SDNN (the standard deviation of the NN interval, i.e. the square root of variance) (19.2ms; p=0.007, Mann-Whitney's U-Test) and total power (242ms(2); p=0.044, Mann...

  14. Making the Most of the "Daphnia" Heart Rate Lab: Optimizing the Use of Ethanol, Nicotine & Caffeine

    Science.gov (United States)

    Corotto, Frank; Ceballos, Darrel; Lee, Adam; Vinson, Lindsey

    2010-01-01

    Students commonly test the effects of chemical agents on the heart rate of the crustacean "Daphnia" magna, but the procedure has never been optimized. We determined the effects of three concentrations of ethanol, nicotine, and caffeine and of a control solution on heart rate in "Daphnia." Ethanol at 5% and 10% (v/v) reduced mean heart rate to…

  15. A randomised, simulated study assessing auscultation of heart rate at birth

    NARCIS (Netherlands)

    Voogdt, Kevin G. J. A.; Morrison, Allison C.; Wood, Fiona E.; van Elburg, Ruurd M.; Wyllie, Jonathan P.

    2010-01-01

    Heart rate is a primary clinical indicator directing newborn resuscitation. The time taken to assess the heart rate by auscultation in relation to accuracy during newborn resuscitation is not known. To assess both the accuracy and time taken to assess heart rate by stethoscope in simulated

  16. The challenge of home discharge with a total artificial heart: the La Pitie Salpetriere experience.

    Science.gov (United States)

    Demondion, Pierre; Fournel, Ludovic; Niculescu, Michaela; Pavie, Alain; Leprince, Pascal

    2013-11-01

    The total artificial heart (TAH) helps to counteract the current decrease in heart donors and is likely to bridge patients to transplant under favourable conditions. Today's mobile consoles facilitate home discharge. The aim of this study was to report on the La Pitie Hospital experience with CardioWest TAH recipients, and more particularly, on generally successful outpatient' management. A retrospective analysis was performed on clinical and biological data from patients implanted with a TAH between December 2006 and July 2010 in a single institution. Morbi-mortality during hospital stay, number and causes of rehospitalizations, quality of life during home discharge, bridge to transplant results and survival have all been analysed. Twenty-seven patients were implanted with the CardioWest. Fifteen patients (55.5%) died during support. Prior to home discharge, the most frequent cause of death was multi-organ failure (46.6%). Twelve patients were discharged home from hospital within a median of 88 days [range 35-152, interquartile range 57] postimplantation. Mean rehospitalization rate was 1.2 by patient, on account of device infection (n = 7), technical problems with the console (n = 3) and other causes (n = 4). Between discharge and transplant, patients spent 87% of their support time out of hospital. All patients who returned home with the TAH were subsequently transplanted, and 1 died in post-transplant. Despite the morbidity and mortality occurring during the postimplantation period, home discharge with a TAH is possible. Portables drivers allow for a safe return home. Aside from some remaining weak points such as infectious complications or noise, CardioWest TAH allows for successful rehabilitation of graft candidates, and assures highly satisfactory transplant results.

  17. Experience with the SynCardia total artificial heart in a Canadian centre.

    Science.gov (United States)

    Nguyen, Anthony; Pellerin, Michel; Perrault, Louis P; White, Michel; Ducharme, Anique; Racine, Normand; Carrier, Michel

    2017-12-01

    The SynCardia total artificial heart (TAH) provides complete circulatory support by replacing both native ventricles. Accepted indications include bridge to transplantation and destination therapy. We review our experience with TAH implantation during a period when axial flow pump became available. We retrospectively analyzed the demographics, clinical characteristics and survival of all patients receiving the TAH. From September 2004 to November 2016, 13 patients (12 men, mean age 45 ± 13 yr) received the TAH for refractory cardiogenic shock secondary to idiopathic (56%) or ischemic (17%) cardiomyopathy and to other various causes (33%). Before implantation, mean ejection fraction was 14% ± 4%, 7 (54%) patients had previous cardiac surgery, 4 (31%) were on mechanical ventilation, and 3 (23%) patients were on dialysis. The mean duration of TAH support was 46 ± 40 days. Three (23%) patients died while on support after a mean of 15 days. Actuarial survival on support was 77% ± 12% at 30 days after implantation. Complications on support included stroke ( n = 1, 8%), acute respiratory distress syndrome requiring prolonged intubation ( n = 5, 38%) and acute renal failure requiring temporary dialysis ( n = 5, 38%). Ten (77%) patients survived to be transplanted after a mean of 52 ± 42 days of support. Actuarial survival rates after transplant were 67% ± 16% at 1 month and 56% ± 17% at 1 year after transplantation. The TAH provides an alternative with low incidence of neurologic events in extremely fragile and complex patients waiting for heart transplantation. Complex and unusual anatomic conditions explained the current use of TAH.

  18. Mercury Exposure and Heart Rate Variability: A Systematic Review

    Science.gov (United States)

    Gribble, Matthew O.; Cheng, Alan; Berger, Ronald D.; Rosman, Lori; Guallar, Eliseo

    2015-01-01

    Background Mercury affects the nervous system and has been implicated in altering heart rhythm and function. We sought to better define its role in modulating heart rate variability, a well-known marker of cardiac autonomic function. Design Systematic review. Methods We searched PubMed, Embase, TOXLINE and DART databases without language restriction. We report findings as a qualitative systematic review because heterogeneity in study design and assessment of exposures and outcomes across studies, as well as other methodological limitations of the literature, precluded a quantitative meta-analysis. Results We identified 12 studies of mercury exposure and heart rate variability in human populations (10 studies involving primarily environmental methylmercury exposure and two studies involving occupational exposure to inorganic mercury) conducted in Japan, the Faroe Islands, Canada, Korea, French Polynesia, Finland and Egypt. The association of prenatal mercury exposure with lower high-frequency band scores (thought to reflect parasympathetic activity) in several studies, in particular the inverse association of cord blood mercury levels with the coefficient of variation of the R-R intervals and with low frequency and high frequency bands at 14 years of age in the Faroe Islands birth cohort study, suggests that early mercury exposure could have a long-lasting effect on cardiac parasympathetic activity. Studies with later environmental exposures to mercury in children or in adults were heterogeneous and did not show consistent associations. Conclusions The evidence was too limited to draw firm causal inferences. Additional research is needed to elucidate the effects of mercury on cardiac autonomic function, particularly as early-life exposures might have lasting impacts on cardiac parasympathetic function. PMID:26231507

  19. Heart rate effects of intraosseous injections using slow and fast rates of anesthetic solution deposition.

    Science.gov (United States)

    Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa

    2008-01-01

    The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe.

  20. Sex differences in obesity associated with total fertility rate.

    Directory of Open Access Journals (Sweden)

    Robert Brooks

    Full Text Available The identification of biological and ecological factors that contribute to obesity may help in combating the spreading obesity crisis. Sex differences in obesity rates are particularly poorly understood. Here we show that the strong female bias in obesity in many countries is associated with high total fertility rate, which is well known to be correlated with factors such as low average income, infant mortality and female education. We also document effects of reduced access to contraception and increased inequality of income among households on obesity rates. These results are consistent with studies that implicate reproduction as a risk factor for obesity in women and that suggest the effects of reproduction interact with socioeconomic and educational factors. We discuss our results in the light of recent research in dietary ecology and the suggestion that insulin resistance during pregnancy is due to historic adaptation to protect the developing foetus during famine. Increased access to contraception and education in countries with high total fertility rate might have the additional benefit of reducing the rates of obesity in women.

  1. Effect of Smoking on Blood Pressure and Resting Heart Rate

    DEFF Research Database (Denmark)

    Linneberg, Allan; Jacobsen, Rikke K; Skaaby, Tea

    2015-01-01

    BACKGROUND: -Smoking is an important cardiovascular disease risk factor, but the mechanisms linking smoking to blood pressure are poorly understood. METHODS AND RESULTS: -Data on 141,317 participants (62,666 never, 40,669 former, 37,982 current smokers) from 23 population-based studies were...... for smoking heaviness in current smokers. In observational analyses, current as compared with never smoking was associated with lower SBP, DBP, and lower hypertension risk, but with higher resting heart rate. In observational analyses amongst current smokers, one cigarette/day higher level of smoking...... heaviness was associated with higher (0.21 beats/minute; 95% CI 0.19; 0.24) resting heart rate, and slightly higher DBP (0.05 mmHg; 95% CI 0.02; 0.08) and SBP (0.08 mmHg; 95% CI 0.03; 0.13). However, in MR analyses amongst current smokers, while each smoking increasing allele of rs16969968/rs1051730...

  2. Exercise training improves heart rate variability after methamphetamine dependency.

    Science.gov (United States)

    Dolezal, Brett Andrew; Chudzynski, Joy; Dickerson, Daniel; Mooney, Larissa; Rawson, Richard A; Garfinkel, Alan; Cooper, Christopher B

    2014-06-01

    Heart rate variability (HRV) reflects a healthy autonomic nervous system and is increased with physical training. Methamphetamine dependence (MD) causes autonomic dysfunction and diminished HRV. We compared recently abstinent methamphetamine-dependent participants with age-matched, drug-free controls (DF) and also investigated whether HRV can be improved with exercise training in the methamphetamine-dependent participants. In 50 participants (MD = 28; DF = 22), resting heart rate (HR; R-R intervals) was recorded over 5 min while seated using a monitor affixed to a chest strap. Previously reported time domain (SDNN, RMSSD, pNN50) and frequency domain (LFnu, HFnu, LF/HF) parameters of HRV were calculated with customized software. MD were randomized to thrice-weekly exercise training (ME = 14) or equal attention without training (MC = 14) over 8 wk. Groups were compared using paired and unpaired t-tests. Statistical significance was set at P ≤ 0.05. Participant characteristics were matched between groups (mean ± SD): age = 33 ± 6 yr; body mass = 82.7 ± 12 kg, body mass index = 26.8 ± 4.1 kg·min. Compared with DF, the MD group had significantly higher resting HR (P HRV indices were similar between ME and MC groups. However, after training, the ME group significantly (all P HRV, based on several conventional indices, was diminished in recently abstinent, methamphetamine-dependent individuals. Moreover, physical training yielded a marked increase in HRV, representing increased vagal modulation or improved autonomic balance.

  3. Smartphone-based photoplethysmographic imaging for heart rate monitoring.

    Science.gov (United States)

    Alafeef, Maha

    2017-07-01

    The purpose of this study is to make use of visible light reflected mode photoplethysmographic (PPG) imaging for heart rate (HR) monitoring via smartphones. The system uses the built-in camera feature in mobile phones to capture video from the subject's index fingertip. The video is processed, and then the PPG signal resulting from the video stream processing is used to calculate the subject's heart rate. Records from 19 subjects were used to evaluate the system's performance. The HR values obtained by the proposed method were compared with the actual HR. The obtained results show an accuracy of 99.7% and a maximum absolute error of 0.4 beats/min where most of the absolute errors lay in the range of 0.04-0.3 beats/min. Given the encouraging results, this type of HR measurement can be adopted with great benefit, especially in the conditions of personal use or home-based care. The proposed method represents an efficient portable solution for HR accurate detection and recording.

  4. Temporal discounting and heart rate reactivity to stress.

    Science.gov (United States)

    Diller, James W; Patros, Connor H G; Prentice, Paula R

    2011-07-01

    Temporal discounting is the reduction of the value of a reinforcer as a function of increasing delay to its presentation. Impulsive individuals discount delayed consequences more rapidly than self-controlled individuals, and impulsivity has been related to substance abuse, gambling, and other problem behaviors. A growing body of literature has identified biological correlates of impulsivity, though little research to date has examined relations between delay discounting and markers of poor health (e.g., cardiovascular reactivity to stress). We evaluated the relation between one aspect of impulsivity, measured using a computerized temporal discounting task, and heart rate reactivity, measured as a change in heart rate from rest during a serial subtraction task. A linear regression showed that individuals who were more reactive to stress responded more impulsively (i.e., discounted delayed reinforcers more rapidly). When results were stratified by gender, the effect was observed for females, but not for males. This finding supports previous research on gender differences in cardiovascular reactivity and suggests that this type of reactivity may be an important correlate of impulsive behavior. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Physiological characterization of the SynCardia total artificial heart in a mock circulation system.

    Science.gov (United States)

    Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J

    2015-01-01

    The SynCardia total artificial heart (TAH) has emerged as an effective, life-saving biventricular replacement system for a wide variety of patients with end-stage heart failure. Although the clinical performance of the TAH is established, modern physiological characterization, in terms of elastance behavior and pressure-volume (PV) characterization has not been defined. Herein, we examine the TAH in terms of elastance using a nonejecting left ventricle, and then characterize the PV relation of the TAH by varying preload and afterload parameters using a Donovan Mock Circulatory System. We demonstrate that the TAH does not operate with time-varying elastance, differing from the human heart. Furthermore, we show that the TAH has a PV relation behavior that also differs from that of the human heart. The TAH does exhibit Starling-like behavior, with output increasing via preload-dependent mechanisms, without reliance on an alteration of inotropic state within the operating window of the TAH. Within our testing range, the TAH is insensitive to variations in afterload; however, this insensitivity has a limit, the limit being the maximum driving pressure of the pneumatic driver. Understanding the physiology of the TAH affords insight into the functional parameters that govern artificial heart behavior providing perspective on differences compared with the human heart.

  6. A note on total muon capture rates in heavy nuclei

    International Nuclear Information System (INIS)

    Parthasarathy, R.

    1978-03-01

    The results of calculations of the total capture rates in heavy nuclei, into account the nucleon velocity-dependent terms in the Fujii-Primakoff Hamiltonian and the effective mass of nucleons inside the nucleus, are presented along with the recent experimental data. The results are in general agreement with experiment. However, they indicate a possible deviation from SU(4) symmetry and, in some nuclei, support the Salam-Strathdee idea of the vanishing of the Cabibbo angle at large magnetic fields.

  7. Failure rate of cemented and uncemented total hip replacements

    DEFF Research Database (Denmark)

    Makela, K. T.; Matilainen, M.; Pulkkinen, P.

    2014-01-01

    ). Participants 347 899 total hip replacements performed during 1995-2011. Main outcome measures Probability of implant survival (Kaplan-Meier analysis) along with implant survival with revision for any reason as endpoint (Cox multiple regression) adjusted for age, sex, and diagnosis in age groups 55-64, 65......Objective To assess the failure rate of cemented, uncemented, hybrid, and reverse hybrid total hip replacements in patients aged 55 years or older. Design Register study. Setting Nordic Arthroplasty Register Association database (combined data from Sweden, Norway, Denmark, and Finland......-74, and 75 years or older. Results The proportion of total hip replacements using uncemented implants increased rapidly towards the end of the study period. The 10 year survival of cemented implants in patients aged 65 to 74 and 75 or older (93.8%, 95% confidence interval 93.6% to 94.0% and 95.9%, 95...

  8. The slope of the oxygen pulse curve does not depend on the maximal heart rate in elite soccer players

    Directory of Open Access Journals (Sweden)

    Raphael Rodrigues Perim

    2011-01-01

    Full Text Available INTRODUCTION: It is unknown whether an extremely high heart rate can affect oxygen pulse profile during progressive maximal exercise in healthy subjects. OBJECTIVE: Our aim was to compare relative oxygen pulse (adjusted for body weight curves in athletes at their maximal heart rate during treadmill cardiopulmonary exercise testing. METHODS: A total of 180 elite soccer players were categorized in quartiles according to their maximum heart rate values (n = 45. Oxygen consumption, maximum heart rate and relative oxygen pulse curves in the extreme quartiles, Q1 and Q4, were compared at intervals corresponding to 10% of the total duration of a cardiopulmonary exercise testing. RESULTS: Oxygen consumption was similar among all subjects during cardiopulmonary exercise testing; however subjects in Q1 started to exhibit lower maximum heart rate values when 20% of the test was complete. Conversely, the relative oxygen pulse was higher in this group when cardiopulmonary exercise testing was 40% complete (p<.01. Although the slopes of the lines were similar (p = .25, the regression intercepts differed (p<.01 between Q1 and Q4. During the last two minutes of testing, a flat or decreasing oxygen pulse was identified in 20% of the soccer players, and this trend was similar between subjects in Q1 and Q4. CONCLUSION: Relative oxygen pulse curve slopes, which serve as an indirect and non-invasive surrogate for stroke volume, suggest that the stroke volume is similar in young and aerobically fit subjects regardless of the maximum heart rate reached.

  9. Heart rate and time-motion analyses in top junior players during basketball matches

    Directory of Open Access Journals (Sweden)

    Karel Hůlka

    2013-09-01

    Full Text Available BACKGROUND: Basketball performance can be classified as an intermittent physical activity due to the changing situational game conditions and the number of intervening variables. It is necessary to have detailed knowledge about the performance of basketball players during a match as a background for more specific planning of the training process. OBJECTIVE: The aim of this study was to analyse the indicators of internal and external load of basketball player’s performance during a match of U18 top men basketball players as a background for the planning of specific training processes. METHODS: Thirty-two Czech top junior basketball players (male, aged 16.88 ± 0.72 years participated in this research. The heart rate was recorded and time-motion analysis was conducted during six warm-up matches. RESULTS: The average heart rate was measured to be 167.47 ± 13.01 beats • min.–1, which corresponded to 85.06 ± 6.40% of peak heart rate. The percentages of the total time spent over and under 85% were 63.12% and 36.88%, respectively. Average distance covered was measured to be 5,880.91 ± 831.01 meters. The average work : rest ratio was 1 : 7.95 ± 1.83, ranging from 1 : 4.80 to 1 : 10.92. CONCLUSIONS: The results from these matches suggest that the exercise intensity and sprint activity observed during junior basketball are dependent on the player's position and partly on the level of the performance. The heart rate during a match was not dependent on the positions, however, time-motion analysis revealed significant differences between three basketball positions during a match. The combination of heart rate and time-motion analysis is recommended.

  10. Heart rate monitoring in soccer: interest and limits during competitive match play and training, practical application.

    Science.gov (United States)

    Alexandre, Dellal; da Silva, Cristiano Diniz; Hill-Haas, Stephen; Wong, Del P; Natali, Antonio J; De Lima, Jorge R P; Bara Filho, Mauricio G B; Marins, Joao J C B; Garcia, Emerson Silami; Karim, Chamari

    2012-10-01

    The identification of physiological loads imposed by soccer training or match play reveals essential information, which may help improve training and recovery strategies. Until today, the use of heart rate (HR) monitoring is not standardized in soccer. Thus, the aim of this review was to analyze, determine and compare the exercise intensity (EI) monitored by HR in professional, youth, and recreational soccer players during matches and training sessions using a meta-analysis. Heart rate is one of the most common physiological variables used to determine exercise internal training load. The mean EI recorded during competitive matches was described as 70-80% of VO2max or 80-90% of maximal heart rate (HRmax), independent of the playing level. With respect to HR training zones, approximately 65% of the total match duration is spent at intensity of 70-90% HRmax and rarely below 65% HRmax. However, although HRmax is mostly employed in the literature, monitoring EI should be expressed in relation to reserve heart rate, as it was described as a more reliable indicator of HR, allowing interindividual comparisons. The HR response according to the playing position indicates that midfielders are characterized by the highest EI, followed by forwards and fullbacks. Moreover, in the second half of the match, the EI is lower than that observed during the first half; this reduction could be correlated with the level of the player's physical conditioning. Consequently, coaches may favor the use of interval training or small-sided training games because these are shown to improve both aerobic capacity and the ability to repeat high-intensity actions. Small-sided games allow reaching similar HR responses to those found during interval training and match play but with greater heterogeneity values. Future investigations should include a larger sample of players with special reference to playing position and the expression of EI in percentage of the reserve heart rate, analyzing the

  11. An Overview of Heart Rate Variability Metrics and Norms

    Directory of Open Access Journals (Sweden)

    Fred Shaffer

    2017-09-01

    Full Text Available Healthy biological systems exhibit complex patterns of variability that can be described by mathematical chaos. Heart rate variability (HRV consists of changes in the time intervals between consecutive heartbeats called interbeat intervals (IBIs. A healthy heart is not a metronome. The oscillations of a healthy heart are complex and constantly changing, which allow the cardiovascular system to rapidly adjust to sudden physical and psychological challenges to homeostasis. This article briefly reviews current perspectives on the mechanisms that generate 24 h, short-term (~5 min, and ultra-short-term (<5 min HRV, the importance of HRV, and its implications for health and performance. The authors provide an overview of widely-used HRV time-domain, frequency-domain, and non-linear metrics. Time-domain indices quantify the amount of HRV observed during monitoring periods that may range from ~2 min to 24 h. Frequency-domain values calculate the absolute or relative amount of signal energy within component bands. Non-linear measurements quantify the unpredictability and complexity of a series of IBIs. The authors survey published normative values for clinical, healthy, and optimal performance populations. They stress the importance of measurement context, including recording period length, subject age, and sex, on baseline HRV values. They caution that 24 h, short-term, and ultra-short-term normative values are not interchangeable. They encourage professionals to supplement published norms with findings from their own specialized populations. Finally, the authors provide an overview of HRV assessment strategies for clinical and optimal performance interventions.

  12. C-reactive protein, heart rate variability and prognosis in community subjects with no apparent heart disease

    DEFF Research Database (Denmark)

    Sajadieh, A; Nielsen, OW; Rasmussen, Verner

    2006-01-01

    OBJECTIVES: Increased C-reactive protein (CRP) and reduced heart rate variability (HRV) both indicate poor prognosis. An inverse association between HRV and CRP has been reported, suggesting an interaction between inflammatory and autonomic systems. However, the prognostic impact of this interact...... of four HRV measures were significantly associated with increased rate of death or myocardial infarction. In a Cox model with CRP >or=2.5 microg mL(-1), standard deviation for the mean value of the time between normal complexes...... examinations, and 24-h Holter monitoring. Four time domain measures of HRV were studied. All were prospectively followed for up to 5 years. RESULTS: Mean age was 64 years (55-75). During the follow-up, 46 total deaths and 11 cases of definite acute myocardial infarction were observed. Both CRP and three...

  13. Worldwide Experience with the Syncardia Total Artificial Heart in the Pediatric Population.

    Science.gov (United States)

    Morales, David L S; Lorts, Angela; Rizwan, Raheel; Zafar, Farhan; Arabia, Francisco A; Villa, Chet R

    Individual centers have documented the use of the Syncardia Total Artificial Heart (TAH) in adolescents with heart failure; however, the number of patients at any given center is small. Herein, we describe the worldwide experience for all patients ≤21 years old supported with the TAH between May 2005 and May 2015 (n = 43). The number of patients experiencing a positive outcome at 60, 90, and 120 days were 30 (70%), 27 (63%), and 25 (58%), respectively. Successful bridge to transplantation varied by diagnosis, but outcomes reported are similar to adults supported with the TAH or biventricular assist devices.

  14. Separating the effect of respiration from the heart rate variability for cases of constant harmonic breathing

    Directory of Open Access Journals (Sweden)

    Kircher Michael

    2015-09-01

    Full Text Available Heart Rate Variability studies are a known measure for the autonomous control of the heart rate. In special situations, its interpretation can be ambiguous, since the respiration has a major influence on the heart rate variability. For this reason it has often been proposed to measure Heart Rate Variability, while the subjects are breathing at a constant respiration rate. That way the spectral influence of the respiration is known. In this work we propose to remove this constant respiratory influence from the heart rate and the Heart Rate Variability parameters to gain respiration free autonomous controlled heart rate signal. The spectral respiratory component in the heart rate signal is detected and characterized. Subsequently the respiratory effect on Heart Rate Variability is removed using spectral filtering approaches, such as the Notch filter or the Raised Cosine filter. As a result new decoupled Heart Variability parameters are gained, which could lead to new additional interpretations of the autonomous control of the heart rate.

  15. Simultaneous measurement of instantaneous heart rate and chest wall plethysmography in short-term, metronome guided heart rate variability studies: suitability for assessment of autonomic dysfunction.

    Science.gov (United States)

    Perring, S; Jones, E

    2003-08-01

    Instantaneous heart rate and chest wall motion were measured using a 3-lead ECG and an air pressure chest wall plethysmography system. Chest wall plethysmography traces were found to accurately represent the breathing pattern as measured by spirometry (average correlation coefficient 0.944); though no attempt was made to calibrate plethysmography voltage output to tidal volume. Simultaneous measurements of heart rate and chest wall motion were made for short periods under metronome guided breathing at 6 breaths per minute. The average peak to trough heart rate change per breath cycle (AVEMAX) and maximum correlation between heart rate and breathing cycle (HRBRCORR) were measured. Studies of 44 normal volunteers indicated clear inverse correlation of heart rate variability parameters with age (AVEMAX R = -0.502, P < 0.001) but no significant change in HRBRCORR with age (R = -0.115). Comparison of normal volunteers with diabetics with no history of symptoms associated with autonomic failure indicated significant lower heart rate variability in diabetics (P = 0.005 for AVEMAX) and significantly worse correlation between heart rate and breathing (P < 0.001 for HRBRCORR). Simultaneous measurement of heart rate and breathing offers the possibility of more sensitive diagnosis of autonomic failure in a simple bedside test and gives further insight into the nature of cardio-ventilatory coupling.

  16. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability

    Directory of Open Access Journals (Sweden)

    E.R. Migliaro

    2001-04-01

    Full Text Available In order to assess the relative influence of age, resting heart rate (HR and sedentary life style, heart rate variability (HRV was studied in two different groups. The young group (YG consisted of 9 sedentary subjects aged 15 to 20 years (YG-S and of 9 nonsedentary volunteers (YG-NS also aged 15 to 20. The elderly sedentary group (ESG consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min. R-R variability was calculated in the time-domain by means of the root mean square successive differences. Frequency-domain HRV was evaluated by power spectrum analysis considering high frequency and low frequency bands. In the YG the effort tolerance was ranked in a bicycle stress test. HR was similar for both groups while ESG showed a reduced HRV compared with YG. Within each group, HRV displayed a negative correlation with HR. Although YG-NS had better effort tolerance than YG-S, their HR and HRV were not significantly different. We conclude that HRV is reduced with increasing HR or age, regardless of life style. The results obtained in our short-term study agree with others of longer duration by showing that age and HR are the main determinants of HRV. Our results do not support the idea that changes in HRV are related to regular physical activity.

  17. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability.

    Science.gov (United States)

    Migliaro, E R; Contreras, P; Bech, S; Etxagibel, A; Castro, M; Ricca, R; Vicente, K

    2001-04-01

    In order to assess the relative influence of age, resting heart rate (HR) and sedentary life style, heart rate variability (HRV) was studied in two different groups. The young group (YG) consisted of 9 sedentary subjects aged 15 to 20 years (YG-S) and of 9 nonsedentary volunteers (YG-NS) also aged 15 to 20. The elderly sedentary group (ESG) consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min). R-R variability was calculated in the time-domain by means of the root mean square successive differences. Frequency-domain HRV was evaluated by power spectrum analysis considering high frequency and low frequency bands. In the YG the effort tolerance was ranked in a bicycle stress test. HR was similar for both groups while ESG showed a reduced HRV compared with YG. Within each group, HRV displayed a negative correlation with HR. Although YG-NS had better effort tolerance than YG-S, their HR and HRV were not significantly different. We conclude that HRV is reduced with increasing HR or age, regardless of life style. The results obtained in our short-term study agree with others of longer duration by showing that age and HR are the main determinants of HRV. Our results do not support the idea that changes in HRV are related to regular physical activity.

  18. Altered Heart Rate Variability During Gaming in Internet Gaming Disorder.

    Science.gov (United States)

    Lee, Deokjong; Hong, Sung Jun; Jung, Young-Chul; Park, Jinsick; Kim, In Young; Namkoong, Kee

    2018-04-01

    Internet gaming disorder (IGD) is characterized by addiction to online gaming and reduced executive control, particularly when individuals are exposed to gaming-related cues. Executive control can be measured as vagally mediated heart rate variability (HRV), which corresponds to variability in the time interval between heart beats. In this study, we investigated whether individuals with IGD have altered HRV while playing online games. We hypothesized that while gaming, individuals with IGD would exhibit phasic suppression of vagally mediated HRV, which would reflect executive control dysfunction during game play. To test this, we measured the changes of HRV when young males with IGD were engaged in real-time online gaming. The changes of HRV were associated with the severity of IGD assessed by self-reports and prefrontal gray matter volume (GMV) calculated by voxel-based morphometry. We included 23 IGD subjects and 18 controls in our analyses. Changes in HRV were not statistically different between IGD subjects and controls. Within the IGD group, however, subjects showed significant decreases in high-frequency (HF) HRV during gaming. Furthermore, the degree of decrease correlated with IGD severity and prefrontal GMV. Importantly, this phasic suppression of HF-HRV in response to gaming did not occur in control subjects. In conclusion, young males with IGD showed an altered HRV response while playing an online game, reflecting their difficulties in executive control over gaming. The dynamics between executive control and reward seeking may be out of balance during game play in IGD.

  19. Is the algorithm used to process heart rate variability data clinically relevant? Analysis in male adolescents.

    Science.gov (United States)

    Soares, Antonio Henrique Germano; Farah, Breno Quintella; Cucato, Gabriel Grizzo; Bastos-Filho, Carmelo José Albanez; Christofaro, Diego Giulliano Destro; Vanderlei, Luiz Carlos Marques; Lima, Aluísio Henrique Rodrigues de Andrade; Ritti-Dias, Raphael Mendes

    2016-01-01

    To analyze whether the algorithm used for the heart rate variability assessment (fast Fourier transform versus autoregressive methods) influenced its association with cardiovascular risk factors in male adolescents. This cross-sectional study included 1,152 male adolescents (aged 14 to 19 years). The low frequency, high frequency components (absolute numbers and normalized units), low frequency/high frequency ratio, and total power of heart rate variability parameters were obtained using the fast Fourier transform and autoregressive methods, while the adolescents were resting in a supine position. All heart rate variability parameters calculated from both methods were different (padolescentes do gênero masculino. Estudo transversal, que incluiu 1.152 adolescentes do gênero masculino (14 a 19 anos). Componentes de baixa e alta frequência (absolutos e unidades normalizadas), razão componente de baixa frequência/componente de alta frequência e poder total da variabilidade da frequência cardíaca foram obtidos em repouso, na posição supina, usando os métodos transformada rápida de Fourier e autorregressivo. Todos os parâmetros da variabilidade da frequência cardíaca para ambos os métodos foram diferentes (padolescentes masculinos, mas essas diferenças não foram clinicamente significativas.

  20. Leukocyte Populations are Associated with Heart Rate Variability After a Triathlon

    Directory of Open Access Journals (Sweden)

    Cruz Germán Hernández

    2016-12-01

    Full Text Available The purpose of this study was to analyze cellular immune components and their association with heart rate variability in triathlon athletes. Twelve athletes were included (age 36.41 ± 5.57 years, body mass 81.84 ± 10.97 kg and blood samples were taken one week before, immediately, at 2 and 48 hours, and one week after competition. Total lymphocytes and their subpopulations, neutrophils, basophils, eosinophils and monocytes were analyzed. At the same time, heart rate variability was recorded for 30 minutes using Polar Team2®. A significant difference between lymphocyte subpopulations and heart rate variability was found in the different study periods. A positive correlation was found between total lymphocytes and rMSSD (r = .736, p <0.05, CD3+ and rMSSD (r = .785, p <0.05, and CD4+ and rMSSD (r = .795, p < 0.05 at the end of the competition. After one week of competition, a negative correlation was found between eosinophils and MRR, SDNN, pNN50, and rMSSD (p <0.01; and basophils and MRR, SDNN, pNN50, and rMSSD (p <0.01; while a positive correlation was found between CD19+ (B cells and pNN50 (r = .678, p <0.05. Our results suggest that it is possible to predict the effect of training with regard to the athlete's performance.

  1. Heart Rate and Initial Presentation of Cardiovascular Diseases (Caliber)

    Science.gov (United States)

    2013-09-17

    Abdominal Aortic Aneurysm; Coronary Heart Disease NOS; Unheralded Coronary Death; Intracerebral Haemorrhage; Heart Failure; Ischemic Stroke; Myocardial Infarction; Stroke; Peripheral Arterial Disease; Stable Angina Pectoris; Subarachnoid Haemorrhage; Transient Ischemic Attack; Unstable Angina; Cardiac Arrest, Sudden Cardiac Death

  2. AbioCor totally implantable artificial heart. How will it impact hospitals?

    Science.gov (United States)

    2002-09-01

    Although heart transplantation remains the most effective treatment for severe heart failure, there are far fewer donor hearts available than there are patients who could benefit from them. One approach to addressing this shortfall is the total artificial heart, or TAH. To date, however, no TAH design has been able to achieve one of the ultimate goals of heart replacement: to allow a patient to live a reasonably normal life without being connected to external machinery. A new design, the AbioCor TAH developed by Abiomed Inc., may make this goal achievable. Thanks to a power system that transfers energy through the skin without the aid of wires, the AbioCor--currently undergoing clinical trials in the United States--allows the patient to be completely mobile. The lack of transcutaneous wires also eliminates the primary source of the infections that have plagued TAH patients in the past. Though it is not without drawbacks, the AbioCor could represent a crucial advance in TAH technology. In this Technology Overview, we describe the operation of the AbioCor and discuss its likely impact on hospitals if it is approved for marketing in the United States. We also discuss a related cardiac-support technology: ventricular assist devices (VADs), which may also be used for permanent cardiac support someday.

  3. Effect of atrioventricular conduction on heart rate variability

    KAUST Repository

    Ahmad, Talha Jamal

    2011-08-01

    This paper discusses the effect of atrioventricular conduction time (AVCT) on the short-term Heart Rate Variability (HRV) by computing HRV parameters using intervals between the onsets of successive P waves (PP time series) for three groups: normal, arrhythmia and sudden cardiac death (SCD) patients. A very precise wavelet transform based ECG delineator was developed to detect PP, PR and RR time series. Mean PR variation in arrhythmia and SCD group was found to be significantly high as compared to the normal group. It was observed that when PR variations in arrhythmia and SCD cases crossed a certain threshold, RR variability no longer provided a very accurate estimate of HRV. In such cases, PP variability was able to provide a better assessment of HRV. © 2011 IEEE.

  4. The role of heart rate variability in sports physiology.

    Science.gov (United States)

    Dong, Jin-Guo

    2016-05-01

    Heart rate variability (HRV) is a relevant marker reflecting cardiac modulation by sympathetic and vagal components of the autonomic nervous system (ANS). Although the clinical application of HRV is mainly associated with the prediction of sudden cardiac death and assessing cardiovascular and metabolic illness progression, recent observations have suggested its applicability to physical exercise training. HRV is becoming one of the most useful tools for tracking the time course of training adaptation/maladaptation of athletes and in setting the optimal training loads leading to improved performances. However, little is known regarding the role of HRV and the internal effects of physical exercise on an athlete, which may be useful in designing fitness programs ensuring sufficient training load that may correspond with the specific ability of the athlete. In this review, we offer a comprehensive assessment of investigations concerning the interrelation between HRV and ANS, and examine how the application of HRV to physical exercise may play a role in sports physiology.

  5. Heart rate, startle response, and intrusive trauma memories

    Science.gov (United States)

    Chou, Chia-Ying; Marca, Roberto La; Steptoe, Andrew; Brewin, Chris R

    2014-01-01

    The current study adopted the trauma film paradigm to examine potential moderators affecting heart rate (HR) as an indicator of peritraumatic psychological states and as a predictor of intrusive memories. We replicated previous findings that perifilm HR decreases predicted the development of intrusive images and further showed this effect to be specific to images rather than thoughts, and to detail rather than gist recognition memory. Moreover, a group of individuals showing both an atypical sudden reduction in HR after a startle stimulus and higher trait dissociation was identified. Only among these individuals was lower perifilm HR found to indicate higher state dissociation, fear, and anxiety, along with reduced vividness of intrusions. The current findings emphasize how peritraumatic physiological responses relate to emotional reactions and intrusive memory. The moderating role of individual difference in stress defense style was highlighted. PMID:24397333

  6. Algorithms for Computerized Fetal Heart Rate Diagnosis with Direct Reporting

    Directory of Open Access Journals (Sweden)

    Kazuo Maeda

    2015-06-01

    Full Text Available Aims: Since pattern classification of fetal heart rate (FHR was subjective and enlarged interobserver difference, objective FHR analysis was achieved with computerized FHR diagnosis. Methods: The computer algorithm was composed of an experts’ knowledge system, including FHR analysis and FHR score calculation, and also of an objective artificial neural network system with software. In addition, a FHR frequency spectrum was studied to detect ominous sinusoidal FHR and the loss of baseline variability related to fetal brain damage. The algorithms were installed in a central-computerized automatic FHR monitoring system, which gave the diagnosis rapidly and directly to the attending doctor. Results: Clinically perinatal mortality decreased significantly and no cerebral palsy developed after introduction of the centralized system. Conclusion: The automatic multichannel FHR monitoring system improved the monitoring, increased the objectivity of FHR diagnosis and promoted clinical results.

  7. Muscle metaboreflex and autonomic regulation of heart rate in humans

    DEFF Research Database (Denmark)

    Fisher, James P; Adlan, Ahmed M; Shantsila, Alena

    2013-01-01

    ) conditions, but attenuated with β-adrenergic blockade (0.2 ± 1 beats min(-1); P > 0.05 vs. rest). Thus muscle metaboreflex activation-mediated increases in HR are principally attributable to increased cardiac sympathetic activity, and only following exercise with a large muscle mass (PEI following leg......We elucidated the autonomic mechanisms whereby heart rate (HR) is regulated by the muscle metaboreflex. Eight male participants (22 ± 3 years) performed three exercise protocols: (1) enhanced metaboreflex activation with partial flow restriction (bi-lateral thigh cuff inflation) during leg cycling...... exercise, (2) isolated muscle metaboreflex activation (post-exercise ischaemia; PEI) following leg cycling exercise, (3) isometric handgrip followed by PEI. Trials were undertaken under control (no drug), β1-adrenergic blockade (metoprolol) and parasympathetic blockade (glycopyrrolate) conditions. HR...

  8. Resting Heart Rate Is Not Associated with Cognitive Function

    DEFF Research Database (Denmark)

    Wod, M; Jensen, M T; Galatius, S

    2018-01-01

    Aims: In order to examine the hypothesis that elevated resting heart rate (RHR) is associated with impaired cognitive score, we investigated the relationship between RHR and cognitive score in middle-aged, elderly and old Danish subjects from the general population. Methods: Composite cognitive s...... cognitive score (1,049 pairs of 2,049 pairs [51% (95% CI 49–53), p relation to cognitive function in the general population....... and hypertension, RHR was not associated with cognitive function. Furthermore, the intrapair analyses showed that RHR was not associated with cognitive score testing within twin pairs, as measured by the proportion of twin pairs in which the twin with higher RHR also was the twin with the lowest composite...

  9. Heart rate variability analysis with the R package RHRV

    CERN Document Server

    García Martínez, Constantino Antonio; Vila, Xosé A; Lado Touriño, María José; Rodríguez-Liñares, Leandro; Rodríguez Presedo, Jesús María; Méndez Penín, Arturo José

    2017-01-01

    This book introduces readers to the basic concepts of Heart Rate Variability (HRV) and its most important analysis algorithms using a hands-on approach based on the open-source RHRV software. HRV refers to the variation over time of the intervals between consecutive heartbeats. Despite its apparent simplicity, HRV is one of the most important markers of the autonomic nervous system activity and it has been recognized as a useful predictor of several pathologies. The book discusses all the basic HRV topics, including the physiological contributions to HRV, clinical applications, HRV data acquisition, HRV data manipulation and HRV analysis using time-domain, frequency-domain, time-frequency, nonlinear and fractal techniques. Detailed examples based on real data sets are provided throughout the book to illustrate the algorithms and discuss the physiological implications of the results. Offering a comprehensive guide to analyzing beat information with RHRV, the book is intended for masters and Ph.D. students in v...

  10. Resting and postexercise heart rate variability in professional handball players.

    Science.gov (United States)

    Kayacan, Yildirim; Yildiz, Sedat

    2016-03-01

    The aim of this study was to evaluate heart rate variability (HRV) in professional handball players during rest and following a 5 min mild jogging exercise. For that purpose, electrocardiogram (ECG) of male handball players (N.=12, mean age 25±3.95 years) and sedentary controls (N.=14, mean age 23.5±2.95 years) were recorded for 5 min at rest and just after 5 min of mild jogging. ECGs were recorded and following HRV parameters were calculated: time-domain variables such as heart rate (HR), average normal-to-normal RR intervals, standard deviation of normal-to-normal RR intervals, square root of the mean of the squares of differences between adjacent NN intervals, percentage of differences between adjacent NN intervals that are greater than 50 milliseconds (pNN50), and frequency-domain variables such as very low frequency, low (LF) and high frequency (HF) of the power and LF/HF ratio. Unpaired t-test was used to find out differences among groups while paired t-test was used for comparison of each group for pre- and postjogging HRV. Pearson correlations were carried out to find out the relationships between the parameters. Blood pressures were not different between handball players and sedentary controls but exercise increased systolic blood pressure (Phandball players (Phandball players (Phandball players in response to a mild, short-time (5 min) jogging exercise. However, in sedentary subjects, either the sympathetic regulation of the autonomous nervous system increased or vagal withdrawal occurred.

  11. Heart rate variability in workers chronically exposed to lead.

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Chlebda, Ewa

    2004-07-01

    Lead is a strong neurotoxin. The effects of lead on the activity of the autonomic nervous system, assessed by the use of heart rate variability (HRV) analysis, have not yet been established. To assess the effects of occupational chronic lead exposure on the autonomic nervous system activity. The study group consisted of 22 copper foundry workers (mean age 41.8+/-8.7 years) who had elevated parameters of lead overload and were admitted to the hospital for chelate therapy. The control group consisted of 13 age-matched healthy males. Lead concentration was measured with the use of atomic absorption spectrophotometry, and concentration of free protoporphyrins in erythrocytes (FEP) using a fluorometric method. Each patient underwent 24-hour ambulatory ECG monitoring, and standard short-term as well as long-term HRV parameters were obtained. There were no significant differences between patients and controls in HRV parameters. In the control group, HRV parameters correlated with age. In patients, a significant negative correlation between lead concentration and some short-term HRV parameters calculated during the night was found: SDNN (r=-0.48, p<0.05), TP (r=-0.48, p<0.01) and LF (r=-0.48, p<0.01). In patients, a negative correlation between lead concentration and HFnight/HFday index was found (r=-0.47 p<0.01), whereas in controls this correlation was positive (r=0.66 p<0.05). Overall HRV indices are similar in subjects exposed to lead and in healthy controls. A decrease in the physiological elevation of HF values during the night, together with an increase in lead blood concentration and lack of relationship between age and HRV parameters in workers chronically exposed to lead may suggest disturbances of the autonomic system. In subjects not exposed to lead a decrease in heart rate with an increase in FEP concentration was observed.

  12. Cuff inflation during ambulatory blood pressure monitoring and heart rate

    Directory of Open Access Journals (Sweden)

    Mia Skov-Madsen

    2008-11-01

    Full Text Available Mia Skov-Madsen, My Svensson, Jeppe Hagstrup ChristensenDepartment of Nephrology, Aarhus University Hospital, Aalborg, DenmarkIntroduction: Twenty four-hour ambulatory blood pressure monitoring is a clinically validated procedure in evaluation of blood pressure (BP. We hypothesised that the discomfort during cuff inflation would increase the heart rate (HR measured with 24-h ambulatory BP monitoring compared to a following HR measurement with a 24-h Holter monitor.Methods: The study population (n = 56 were recruited from the outpatient’s clinic at the Department of Nephrology, Aalborg Hospital, Aarhus University Hospital at Aalborg, Denmark. All the patients had chronic kidney disease (CKD. We compared HR measured with a 24-h Holter monitor with a following HR measured by a 24-h ambulatory BP monitoring.Results: We found a highly significant correlation between the HR measured with the Holter monitor and HR measured with 24-h ambulatory blood pressure monitoring (r = 0.77, p < 0.001. Using the Bland-Altman plot, the mean difference in HR was only 0.5 beat/min during 24 hours with acceptable limits of agreement for both high and low HR levels. Dividing the patients into groups according to betablocker treatment, body mass index, age, sex, angiotensin-converting enzyme inhibitor treatment, statins treatment, diuretic treatment, or calcium channel blocker treatment revealed similar results as described above.Conclusion: The results indicate that the discomfort induced by cuff inflation during 24-h ambulatory BP monitoring does not increase HR. Thus, 24-h ambulatory BP monitoring may be a reliable measurement of the BP among people with CKD.Keywords: ambulatory blood pressure monitoring, Holter monitoring, heart rate, chronic kidney disease, hypertension

  13. [The exercise training restores the heart rate variability in heart failure patients. A systematic review].

    Science.gov (United States)

    Segovia, Victoria; Manterola, Carlos; González, Marcelo; Rodríguez-Núñez, Iván

    Cardiovascular diseases are a significant cause of morbidity and mortality in the general population. In this sense, the autonomic imbalance is the cornerstone of the pathophysiology underlying the development of these diseases. The aim of this study was to determine the efficacy of exercise training on heart rate variability (HRV) in adult patients with chronic heart failure. A systematic literature review was conducted in electronic databases. The considered studies were randomised clinical trials, quasi-experimental studies with non-randomised control group, quasi-experimental studies with analysis of pre- and post- intervention, and crossover studies with randomly assigned training and non-training periods. The standardised mean differences were calculated between pre- and post-intervention in both the control and experimental group. Within-subject analysis of the control group showed no statistical significance in the standardised mean differences of HRV. In the experimental group, the standardised mean differences were positive for the root mean square of successive difference (+0.468±0.215; P=.032), high frequency band (HF) (0.934±0.256; P < .001) and low frequency band (LF) (< 0.415±0.096; P=.001). Moreover, the standardised mean difference was negative for LF/HF (-0.747±0.369, P=<.044). On the other hand, only 3 studies entered the comparative meta-analysis. The effect of exercise training was favourable for the experimental group in LF/HF (-2.21±95% CI: -3.83 to -0.60), HF, and LF. The exercise training was effective in increasing HRV and restoring the autonomic balance in patients with heart failure. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  14. Localised photoplethysmography imaging for heart rate estimation of pre-term infants in the clinic

    Science.gov (United States)

    Chaichulee, Sitthichok; Villarroel, Mauricio; Jorge, João.; Arteta, Carlos; Green, Gabrielle; McCormick, Kenny; Zisserman, Andrew; Tarassenko, Lionel

    2018-02-01

    Non-contact vital-sign estimation allows the monitoring of physiological parameters (such as heart rate, respiratory rate, and peripheral oxygen saturation) without contact electrodes or sensors. Our recent work has demonstrated that a convolutional neural network (CNN) can be used to detect the presence of a patient and segment the patient's skin area for vital-sign estimation, thus enabling the automatic continuous monitoring of vital signs in a hospital environment. In a study approved by the local Research Ethical Committee, we made video recordings of pre-term infants nursed in a Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital in Oxford, UK. We extended the CNN model to detect the head, torso and diaper of the infants. We extracted multiple photoplethysmographic imaging (PPGi) signals from each body part, analysed their signal quality, and compared them with the PPGi signal derived from the entire skin area. Our results demonstrated the benefits of estimating heart rate combined from multiple regions of interest using data fusion. In the test dataset, we achieved a mean absolute error of 2.4 beats per minute for 80% (31.1 hours) from a total recording time of 38.5 hours for which both reference heart rate and video data were valid.

  15. Effects of slow breathing rate on heart rate variability and arterial baroreflex sensitivity in essential hypertension.

    Science.gov (United States)

    Li, Changjun; Chang, Qinghua; Zhang, Jia; Chai, Wenshu

    2018-05-01

    This study is to investigate the effects of slow breathing on heart rate variability (HRV) and arterial baroreflex sensitivity in essential hypertension.We studied 60 patients with essential hypertension and 60 healthy controls. All subjects underwent controlled breathing at 8 and 16 breaths per minute. Electrocardiogram, respiratory, and blood pressure signals were recorded simultaneously. We studied effects of slow breathing on heart rate, blood pressure and respiratory peak, high-frequency (HF) power, low-frequency (LF) power, and LF/HF ratio of HRV with traditional and corrected spectral analysis. Besides, we tested whether slow breathing was capable of modifying baroreflex sensitivity in hypertensive subjects.Slow breathing, compared with 16 breaths per minute, decreased the heart rate and blood pressure (all P hypertensive subjects. Slow breathing increased baroreflex sensitivity in hypertensive subjects (from 59.48 ± 6.39 to 78.93 ± 5.04 ms/mm Hg, P hypertension. Besides, slow breathing increased baroreflex sensitivity in hypertensive subjects. These demonstrate slow breathing is indeed capable of shifting sympatho-vagal balance toward vagal activities and increasing baroreflex sensitivity, suggesting a safe, therapeutic approach for essential hypertension.

  16. The Performance of Short-Term Heart Rate Variability in the Detection of Congestive Heart Failure

    Directory of Open Access Journals (Sweden)

    Fausto Lucena

    2016-01-01

    Full Text Available Congestive heart failure (CHF is a cardiac disease associated with the decreasing capacity of the cardiac output. It has been shown that the CHF is the main cause of the cardiac death around the world. Some works proposed to discriminate CHF subjects from healthy subjects using either electrocardiogram (ECG or heart rate variability (HRV from long-term recordings. In this work, we propose an alternative framework to discriminate CHF from healthy subjects by using HRV short-term intervals based on 256 RR continuous samples. Our framework uses a matching pursuit algorithm based on Gabor functions. From the selected Gabor functions, we derived a set of features that are inputted into a hybrid framework which uses a genetic algorithm and k-nearest neighbour classifier to select a subset of features that has the best classification performance. The performance of the framework is analyzed using both Fantasia and CHF database from Physionet archives which are, respectively, composed of 40 healthy volunteers and 29 subjects. From a set of nonstandard 16 features, the proposed framework reaches an overall accuracy of 100% with five features. Our results suggest that the application of hybrid frameworks whose classifier algorithms are based on genetic algorithms has outperformed well-known classifier methods.

  17. Heart rate variability enhances the prognostic value of established parameters in patients with congestive heart failure.

    Science.gov (United States)

    Krüger, C; Lahm, T; Zugck, C; Kell, R; Schellberg, D; Schweizer, M W F; Kübler, W; Haass, M

    2002-12-01

    This prospective study evaluated whether heart rate variability (HRV) assessed from Holter ECG has prognostic value in addition to established parameters in patients with congestive heart failure (CHF). The study included 222 patients with CHF due to dilated or ischemic cardiomyopathy (left ventricular ejection fraction LVEF 21+/-1%; mean+/-SEM). During a mean follow-up of 15+/-1 months, 38 (17%) patients died and 45 (20%) were hospitalized due to worsening of CHF. The HRV parameter SDNN (standard deviation of all intervals between normal beats) was significantly lower in non-surviving or hospitalized than in event-free patients (118+/-6 vs 142+/-5 ms), as were LVEF (18+/-1 vs 23+/-1%), and peak oxygen uptake during exercise (peak VO(2)) (12.8+/-0.5 vs 15.6+/-0.5 ml/min/kg). While each of these parameters was a risk predictor in univariate analysis, multivariate analysis revealed that HRV provides both independent and additional prognostic information with respect to the risk 'cardiac mortality or deterioration of CHF'. It is concluded that the determination of HRV enhances the prognostic power given by the most widely used parameters LVEF and peak VO(2) in the prediction of mortality or deterioration of CHF and thus enables to improve risk stratification.

  18. Resonance of about-weekly human heart rate rhythm with solar activity change.

    Science.gov (United States)

    Cornelissen, G; Halberg, F; Wendt, H W; Bingham, C; Sothern, R B; Haus, E; Kleitman, E; Kleitman, N; Revilla, M A; Revilla, M; Breus, T K; Pimenov, K; Grigoriev, A E; Mitish, M D; Yatsyk, G V; Syutkina, E V

    1996-12-01

    In several human adults, certain solar activity rhythms may influence an about 7-day rhythm in heart rate. When no about-weekly feature was found in the rate of change in sunspot area, a measure of solar activity, the double amplitude of a circadian heart rate rhythm, approximated by the fit of a 7-day cosine curve, was lower, as was heart rate corresponds to about-weekly features in solar activity and/or relates to a sunspot cycle.

  19. Thrombotic Depositions on Right Impeller of Double-Ended Centrifugal Total Artificial Heart In Vivo.

    Science.gov (United States)

    Karimov, Jamshid H; Horvath, David J; Okano, Shinji; Goodin, Mark; Sunagawa, Gengo; Byram, Nicole; Moazami, Nader; Golding, Leonard A R; Fukamachi, Kiyotaka

    2017-05-01

    The development of total artificial heart devices is a complex undertaking that includes chronic biocompatibility assessment of the device. It is considered particularly important to assess whether device design and features can be compatible long term in a biological environment. As part of the development program for the Cleveland Clinic continuous-flow total artificial heart (CFTAH), we evaluated the device for signs of thrombosis and biological material deposition in four animals that had achieved the intended 14-, 30-, or 90-day durations in each respective experiment. Explanted CFTAHs were analyzed for possible clot buildup at "susceptible" areas inside the pump, particularly the right pump impeller. Depositions of various consistency and shapes were observed. We here report our findings, along with macroscopic and microscopic analysis post explant, and provide computational fluid dynamics data with its potential implications for thrombus formation. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Estimation of physical work load by statistical analysis of the heart rate in a conveyor-belt worker.

    Science.gov (United States)

    Kontosic, I; Vukelić, M; Pancić, M; Kunisek, J

    1994-12-01

    Physical work load was estimated in a female conveyor-belt worker in a bottling plant. Estimation was based on continuous measurement and on calculation of average heart rate values in three-minute and one-hour periods and during the total measuring period. The thermal component of the heart rate was calculated by means of the corrected effective temperature, for the one-hour periods. The average heart rate at rest was also determined. The work component of the heart rate was calculated by subtraction of the resting heart rate and the heart rate measured at 50 W, using a regression equation. The average estimated gross energy expenditure during the work was 9.6 +/- 1.3 kJ/min corresponding to the category of light industrial work. The average estimated oxygen uptake was 0.42 +/- 0.06 L/min. The average performed mechanical work was 12.2 +/- 4.2 W, i.e. the energy expenditure was 8.3 +/- 1.5%.

  1. False Heart Rate Feedback and the Perception of Heart Symptoms in Patients with Congenital Heart Disease and Anxiety

    NARCIS (Netherlands)

    Karsdorp, Petra A.; Kindt, Merel; Rietveld, Simon; Everaerd, Walter; Mulder, Barbara J. M.

    2009-01-01

    Background Little is known about the mechanisms explaining an increased perception of heart symptoms in congenital heart disease (ConHD). In the present study, it was suggested that a combination of high trait anxiety and disease history increases the perception of heart symptoms. Purpose It was

  2. False heart rate feedback and the perception of heart symptoms in patients with congenital heart disease and anxiety

    NARCIS (Netherlands)

    Karsdorp, P.A.; Kindt, M.; Rietveld, S.; Everaerd, W.; Mulder, B.J.M.

    2009-01-01

    Background: Little is known about the mechanisms explaining an increased perception of heart symptoms in congenital heart disease (ConHD). In the present study, it was suggested that a combination of high trait anxiety and disease history increases the perception of heart symptoms. Purpose: It was

  3. Effects of smoking on heart rate at rest and during exercise, and on heart rate recovery, in young adults.

    Science.gov (United States)

    Papathanasiou, George; Georgakopoulos, Dimitris; Papageorgiou, Effie; Zerva, Efthimia; Michalis, Lampros; Kalfakakou, Vasiliki; Evangelou, Angelos

    2013-01-01

    There is an established link between smoking, abnormal heart rate (HR) values, and impaired cardiovascular health in middle-aged or older populations. The purpose of this study was to examine the effects of smoking on resting HR and on HR responses during and after exercise in young adults. A sample of 298 young adults (159 men), aged 20-29 years old, were selected from a large population of health-science students based on health status, body mass index, physical activity, and smoking habit. All subjects underwent a maximal Bruce treadmill test and their HR was recorded during, at peak, and after termination of exercise. Smokers had significantly higher resting HR values than non-smokers. Both female and male smokers showed a significantly slower HR increase during exercise. Female smokers failed to reach their age-predicted maximum HR by 6.0 bpm and males by 3.6 bpm. The actual maximum HR achieved (HRmax) was significantly lower for both female smokers (191.0 bpm vs.198.0 bpm) and male smokers (193.2 bpm vs.199.3 bpm), compared to non-smokers. Heart rate reserve was also significantly lower in female (114.6 bpm vs. 128.1 bpm) and male smokers (120.4 bpm vs. 133.0 bpm). During recovery, the HR decline was significantly attenuated, but only in female smokers. Females had a higher resting HR and showed a higher HR response during sub-maximal exercise compared to males. Smoking was found to affect young smokers' HR, increasing HR at rest, slowing HR increase during exercise and impairing their ability to reach the age-predicted HRmax. In addition, smoking was associated with an attenuated HR decline during recovery, but only in females.

  4. The Effect of Valsartan on Heart Rate Variability and Heart Rate Recovery in Patients with Mild to Moderate Mitral Stenosis

    Directory of Open Access Journals (Sweden)

    Ali Metin Esen

    2010-04-01

    Full Text Available Summary: Atrial fibrillation (AF is known to be one of the most important complications of mitral stenosis (MS. It has been reported that autonomic nervous system (ANS had an effect on AF development, heart rate variability (HRV and heart rate recovery (HRR were under the control of ANS, and their disorders were present in MS. We studied the effect of Valsartan on HRV and HRT, and thus its effect on ANS. Methods: Eleven patients (39±8 years, 10 females with mild to moderate MS were included in the study. Sixteen volunteers (38±8 years, 14 females matched for age and sex were selected for control group. All subjects underwent transthoracic echocardiography (TTE, symptom-limited treadmill test and 24 hour Holter monitorization.The patients were administered 160 mg of Valsartan daily for 14 weeks. TTE, treadmill test and Holter monitorization were repeated at the end of treatment period. In Holter monitorization, the time and frequency domain analysis of HRV and in exercise test, HRR at first and third minutes (HRR1 and HRR3 were examined. Results: Before Valsartan treatment, no significant difference was found in HRR and HRV parameters between the two groups. Systolic and diastolic blood pressure, and also HRR1values were significantly decreased after treatment of Valsartan (117±6 vs. 107±4 mmHg p<0.002, 76±6 vs. 69±9 mmHg p<0.044, 44±14 vs. 33±12 p< 0.014, respectively, while the exercise time was significantly increased (786±114 vs. 846±95 sn p< 0.044. In Holter analysis neither time nor frequency domain of HRV parameters showed a meaningful change. Conclusion: In moderate MS, treatment with Valsartan improved the effort capacity, while autonomic function parameters have been defined on the base of HRV and HRR were not significantly different.

  5. A Soft Total Artificial Heart-First Concept Evaluation on a Hybrid Mock Circulation.

    Science.gov (United States)

    Cohrs, Nicholas H; Petrou, Anastasios; Loepfe, Michael; Yliruka, Maria; Schumacher, Christoph M; Kohll, A Xavier; Starck, Christoph T; Schmid Daners, Marianne; Meboldt, Mirko; Falk, Volkmar; Stark, Wendelin J

    2017-10-01

    The technology of 3D-printing has allowed the production of entirely soft pumps with complex chamber geometries. We used this technique to develop a completely soft pneumatically driven total artificial heart from silicone elastomers and evaluated its performance on a hybrid mock circulation. The goal of this study is to present an innovative concept of a soft total artificial heart (sTAH). Using the form of a human heart, we designed a sTAH, which consists of only two ventricles and produced it using a 3D-printing, lost-wax casting technique. The diastolic properties of the sTAH were defined and the performance of the sTAH was evaluated on a hybrid mock circulation under various physiological conditions. The sTAH achieved a blood flow of 2.2 L/min against a systemic vascular resistance of 1.11 mm Hg s/mL (afterload), when operated at 80 bpm. At the same time, the mean pulmonary venous pressure (preload) was fixed at 10 mm Hg. Furthermore, an aortic pulse pressure of 35 mm Hg was measured, with a mean aortic pressure of 48 mm Hg. The sTAH generated physiologically shaped signals of blood flow and pressures by mimicking the movement of a real heart. The preliminary results of this study show a promising potential of the soft pumps in heart replacements. Further work, focused on increasing blood flow and in turn aortic pressure is required. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. Improvement of energy expenditure prediction from heart rate during running

    International Nuclear Information System (INIS)

    Charlot, Keyne; Borne, Rachel; Richalet, Jean-Paul; Chapelot, Didier; Pichon, Aurélien; Cornolo, Jérémy; Brugniaux, Julien Vincent

    2014-01-01

    We aimed to develop new equations that predict exercise-induced energy expenditure (EE) more accurately than previous ones during running by including new parameters as fitness level, body composition and/or running intensity in addition to heart rate (HR). Original equations predicting EE were created from data obtained during three running intensities (25%, 50% and 70% of HR reserve) performed by 50 subjects. Five equations were conserved according to their accuracy assessed from error rates, interchangeability and correlations analyses: one containing only basic parameters, two containing VO 2max  or speed at VO 2max  and two including running speed with or without HR. Equations accuracy was further tested in an independent sample during a 40 min validation test at 50% of HR reserve. It appeared that: (1) the new basic equation was more accurate than pre-existing equations (R 2  0.809 versus. 0,737 respectively); (2) the prediction of EE was more accurate with the addition of VO 2max  (R 2  = 0.879); and (3) the equations containing running speed were the most accurate and were considered to have good agreement with indirect calorimetry. In conclusion, EE estimation during running might be significantly improved by including running speed in the predictive models, a parameter readily available with treadmill or GPS. (paper)

  7. Heart rate variability biofeedback improves cardiorespiratory resting function during sleep.

    Science.gov (United States)

    Sakakibara, Masahito; Hayano, Junichiro; Oikawa, Leo O; Katsamanis, Maria; Lehrer, Paul

    2013-12-01

    The present study was designed to examine the effect of heart rate variability (HRV) biofeedback on the cardiorespiratory resting function during sleep in daily life. Forty-five healthy young adults were randomly assigned to one of three groups: HRV biofeedback, Autogenic Training(AT), and no-treatment control. Participants in the HRV biofeedback were instructed to use a handheld HRV biofeedback device before their habitual bedtime, those in the AT were asked to listen to an audiotaped instruction before bedtime,and those in the control were asked to engage in their habitual activity before bedtime. Pulse wave signal during sleep at their own residences was measured continuously with a wrist watch-type transdermal photoelectric sensor for three time points. Baseline data were collected on the first night of measurements, followed by two successive nights for HRV biofeedback, AT, or control. Cardiorespiratory resting function was assessed quantitatively as the amplitude of high frequency(HF) component of pulse rate variability, a surrogate measure of respiratory sinus arrhythmia. HF component increased during sleep in the HRV biofeedback group,although it remained unchanged in the AT and control groups. These results suggest that HRV biofeedback before sleep may improve cardiorespiratory resting function during sleep.

  8. Heart rate modulation in stable coronary artery disease without clinical heart failure: What we have already learned from SIGNIFY?

    Directory of Open Access Journals (Sweden)

    Gian Piero Perna

    2016-12-01

    In conclusion, heart rate is a marker of risk but is not a risk factor and/or a target of therapy in patients with stable coronary artery disease and preserved ventricular systolic function. Standard doses of ivabradine are indicated for treatment of angina as an alternative or in addition to beta-blockers, but should not be administered in association with CYP3A4 inhibitors or heart rate-lowering calcium-channel blockers.

  9. Short- and long-term variations in non-linear dynamics of heart rate variability

    DEFF Research Database (Denmark)

    Kanters, J K; Højgaard, M V; Agner, E

    1996-01-01

    OBJECTIVES: The purpose of the study was to investigate the short- and long-term variations in the non-linear dynamics of heart rate variability, and to determine the relationships between conventional time and frequency domain methods and the newer non-linear methods of characterizing heart rate...... rate and describes mainly linear correlations. Non-linear predictability is correlated with heart rate variability measured as the standard deviation of the R-R intervals and the respiratory activity expressed as power of the high-frequency band. The dynamics of heart rate variability changes suddenly...

  10. The effects of sustained manual pressure stimulation according to Vojta Therapy on heart rate variability.

    Science.gov (United States)

    Opavsky, Jaroslav; Slachtova, Martina; Kutin, Miroslav; Hok, Pavel; Uhlir, Petr; Opavska, Hana; Hlustik, Petr

    2018-05-23

    The physiotherapeutic technique of Vojta reflex locomotion is often accompanied by various autonomic activity changes and unpleasant sensations. It is unknown whether these effects are specific to Vojta Therapy. Therefore, the aim of this study was to compare changes in cardiac autonomic control after Vojta reflex locomotion stimulation and after an appropriate sham stimulation. A total of 28 young healthy adults (20.4 - 25.7 years) were enrolled in this single-blind randomized cross-over study. Participants underwent two modes of 20-minute sustained manual pressure stimulation on the surface of the foot on two separate visits. One mode used manual pressure on the lateral heel, i.e., in a zone employed in the Vojta Therapy (active stimulation). The other mode used pressure on the lateral ankle (control), in an area not included among the active zones used by Vojta Therapy and whose activation does not evoke manifestations of reflex locomotion. Autonomic nervous system activity was evaluated using spectral analysis of heart rate variability before and after the intervention. The active stimulation was perceived as more unpleasant than the control stimulation. Heart rate variability parameters demonstrated almost identical autonomic responses after both stimulation types, showing either modest increase in parasympathetic activity, or increased heart rate variability with similar contribution of parasympathetic and sympathetic activity. The results demonstrate changes of cardiac autonomic control in both active and control stimulation, without evidence for a significant difference between the two.

  11. Speed and heart-rate profiles in skating and classical cross-country skiing competitions.

    Science.gov (United States)

    Bolger, Conor M; Kocbach, Jan; Hegge, Ann Magdalen; Sandbakk, Øyvind

    2015-10-01

    To compare the speed and heart-rate profiles during international skating and classical competitions in male and female world-class cross-country skiers. Four male and 5 female skiers performed individual time trials of 15 km (men) and 10 km (women) in the skating and classical techniques on 2 consecutive days. Races were performed on the same 5-km course. The course was mapped with GPS and a barometer to provide a valid course and elevation profile. Time, speed, and heart rate were determined for uphill, flat, and downhill terrains throughout the entire competition by wearing a GPS and a heart-rate monitor. Times in uphill, flat, and downhill terrain were ~55%, 15-20%, and 25-30%, respectively, of the total race time for both techniques and genders. The average speed differences between skating and classical skiing were 9% and 11% for men and women, respectively, and these values were 12% and 15% for uphill, 8% and 13% for flat (all P skating and classical, respectively, with corresponding numbers of 11% and 14% for uphill, 6% and 11% for flat, and 4% and 5% for downhill terrain (all P skating and classical techniques and between the 2 genders were found on uphill terrain. Therefore, these speed differences could not be explained by variations in exercise intensity.

  12. National trends in heart failure hospitalization rates in Slovenia 2004-2012.

    Science.gov (United States)

    Omersa, Daniel; Farkas, Jerneja; Erzen, Ivan; Lainscak, Mitja

    2016-11-01

    Heart failure (HF) hospitalization rates are decreasing in western Europe, but little is known about trends in central and east European countries. We analysed the Slovenian national hospitalization database to determine the burden of HF hospitalization. The Slovenian National Hospital Discharge Registry was searched for HF hospitalizations between 2004 and 2012 in patients aged ≥20 years. A total of 55 531 main HF hospitalizations (43 636 first HF hospitalizations) in 34 406 patients (median age 78 years, 55% female) were recorded. The most common co-morbidities were arterial hypertension (54.3%), atrial fibrillation (40.6%), diabetes mellitus (24.5%), and ischaemic heart disease (21.9%). The number of age-standardized main and first HF hospitalizations per 100 000 population decreased from 249 to 232 (7.1%, P = 0.002) and from 467 to 435 (6.8%, P = 0.074), respectively. Crude main and first HF hospitalization rates increased from 249 to 298 (19.8%, P Slovenia, standardized HF hospitalization rates have decreased but the crude HF hospitalization burden has increased. Readmissions were associated with established cardiovascular risk factors. © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.

  13. Numerical model of total artificial heart hemodynamics and the effect of its size on stress accumulation.

    Science.gov (United States)

    Marom, Gil; Chiu, Wei-Che; Slepian, Marvin J; Bluestein, Danny

    2014-01-01

    The total artificial heart (TAH) is a bi-ventricular mechanical circulatory support device that replaces the heart in patients with end-stage congestive heart failure. The device acts as blood pump via pneumatic activation of diaphragms altering the volume of the ventricular chambers. Flow in and out of the ventricles is controlled by mechanical heart valves. The aim of this study is to evaluate the flow regime in the TAH and to estimate the thrombogenic potential during systole. Toward that goal, three numerical models of TAHs of differing sizes, that include the deforming diaphragm and the blood flow from the left chamber to the aorta, are introduced. A multiphase model with injection of platelet particles is employed to calculate their trajectories. The shear stress accumulation in the three models are calculated along the platelets trajectories and their probability density functions, which represent the `thrombogenic footprint' of the device are compared. The calculated flow regime successfully captures the mitral regurgitation and the flows that open and close the aortic valve during systole. Physiological velocity magnitudes are found in all three models, with higher velocities and increased stress accumulation predicted for smaller devices.

  14. Using Complexity Metrics With R-R Intervals and BPM Heart Rate Measures

    DEFF Research Database (Denmark)

    Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian

    2013-01-01

    Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of inter......Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker...... of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically...

  15. Reliability of heart rate mobile apps in young healthy adults: exploratory study and research directions

    Directory of Open Access Journals (Sweden)

    Maria Parpinel

    2017-06-01

    Full Text Available Background: Recently, a number of smartphone apps appeared that allow for heart rate measurements basing on the photoplethysmography principle. In fact, almost every smartphone now has a camera with flash that could be used for that. Some studies appeared on the reliability of some of those apps, with heterogeneous results. Objectives: The present study aims at adding up evidence in particular during physical activity, by comparing 3 apps on two different platforms (IOs and Android, on a broad range of heart rates. As gold standard, heart rate has been measured with a traditional heart rate monitor. Results: The results suggest that heart rate apps might be used for measuring heart rate for fitness aims for many individuals, but further research is needed to i analyse influence of smartphone features; ii identify personal factors hindering measurements, and iii verify reliability on different measurement sites.

  16. Approximate entropy and point correlation dimension of heart rate variability in healthy subjects

    DEFF Research Database (Denmark)

    Storella, R J; Wood, H W; Mills, K M

    1999-01-01

    The contribution of nonlinear dynamics to heart rate variability in healthy humans was examined using surrogate data analysis. Several measures of heart rate variability were used and compared. Heart rates were recorded for three hours and original data sets of 8192 R-R intervals created. For each...... original data set (n = 34), three surrogate data sets were made by shuffling the order of the R-R intervals while retaining their linear correlations. The difference in heart rate variability between the original and surrogate data sets reflects the amount of nonlinear structure in the original data set....... Heart rate variability was analyzed by two different nonlinear methods, point correlation dimension and approximate entropy. Nonlinearity, though under 10 percent, could be detected with both types of heart rate variability measures. More importantly, not only were the correlations between...

  17. Electrocardiogram application based on heart rate variability ontology and fuzzy markup language

    NARCIS (Netherlands)

    Wang, M.-H.; Lee, C.-S.; Acampora, G.; Loia, V.; Gacek, A.; Pedrycz, W.

    2011-01-01

    The electrocardiogram (ECG) signal is adopted extensively as a low-cost diagnostic procedure to provide information concerning the healthy status of the heart. Heart rate variability (HRV) is a physiological phenomenon where the time interval between heart beats varies. It is measured by the

  18. Heart rate variability in sleep-related migraine without aura.

    Science.gov (United States)

    Vollono, Catello; Gnoni, Valentina; Testani, Elisa; Dittoni, Serena; Losurdo, Anna; Colicchio, Salvatore; Di Blasi, Chiara; Mazza, Salvatore; Farina, Benedetto; Della Marca, Giacomo

    2013-07-15

    This is an observational study aimed to investigate the activity of autonomic nervous system during sleep in patients with sleep-related migraine. Eight consecutive migraineurs without aura were enrolled (6 women and 2 men), aged 30 to 62 years (mean 48.1 ± 9.3 years). Inclusion criteria were: high frequency of attacks (> 5 per month) and occurrence of more than 75% of the attacks during sleep causing an awakening. Patients were compared with a control group of 55 healthy subjects (23 men and 32 women, mean age 54.2 ± 13.0 years), and with a further control group of 8 age- and gender-matched healthy controls. Patient and controls underwent polysomnography and heart rate variability analysis. A significant reduction of the LF/HF ratio during N2 and N3 sleep stages was observed in migraineurs compared with controls. No differences in sleep macrostructure were observed; cyclic alternating pattern (CAP) time and CAP rate were lower in migraineurs than in controls. These findings indicate a peculiar modification of the autonomic balance during sleep in sleep-related migraine. The reduction of LF/HF ratio in NREM sleep was observed in controls, but it was quantitatively much more evident in migraineurs. Changes in LF/HF could be consequent to an autonomic unbalance which could manifest selectively (or alternatively become more evident) during sleep. These findings, together with the reduction in CAP rate, could be an expression of reduced arousability during sleep in patients with sleep-related migraine. The simultaneous involvement of the autonomic, arousal, and pain systems might suggest involvement of the hypothalamic pathways.

  19. [Design of Oxygen Saturation, Heart Rate, Respiration Rate Detection System Based on Smartphone of Android Operating System].

    Science.gov (United States)

    Zhu, Mingshan; Zeng, Bixin

    2015-03-01

    In this paper, we designed an oxygen saturation, heart rate, respiration rate monitoring system based on smartphone of android operating system, physiological signal acquired by MSP430 microcontroller and transmitted by Bluetooth module.

  20. Understanding heart rate alarm adjustment in the intensive care units through an analytical approach.

    Directory of Open Access Journals (Sweden)

    Richard L Fidler

    Full Text Available Heart rate (HR alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue.To understand the relationship between heart rate (HR alarms and adjustments to reduce unnecessary heart rate alarms.Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm. The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server.There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57.HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision.

  1. Glutamate transporter type 3 knockout leads to decreased heart rate possibly via parasympathetic mechanism

    OpenAIRE

    Deng, Jiao; Li, Jiejie; Li, Liaoliao; Feng, Chenzhuo; Xiong, Lize; Zuo, Zhiyi

    2013-01-01

    Parasympathetic tone is a dominant neural regulator for basal heart rate. Glutamate transporters (EAAT) via their glutamate uptake functions regulate glutamate neurotransmission in the central nervous system. We showed that EAAT type 3 (EAAT3) knockout mice had a slower heart rate than wild-type mice when they were anesthetized. We design this study to determine whether non-anesthetized EAAT3 knockout mice have a slower heart rate and, if so, what may be the mechanism for this effect. Young a...

  2. Estimating Energy Expenditure from Heart Rate in Older Adults: A Case for Calibration

    OpenAIRE

    Schrack, Jennifer A.; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M.; Ferrucci, Luigi

    2014-01-01

    Background Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. Objective To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using diffe...

  3. Simulation of a pulsatile total artificial heart: Development of a partitioned Fluid Structure Interaction model

    Science.gov (United States)

    Sonntag, Simon J.; Kaufmann, Tim A. S.; Büsen, Martin R.; Laumen, Marco; Linde, Torsten; Schmitz-Rode, Thomas; Steinseifer, Ulrich

    2013-04-01

    Heart disease is one of the leading causes of death in the world. Due to a shortage in donor organs artificial hearts can be a bridge to transplantation or even serve as a destination therapy for patients with terminal heart insufficiency. A pusher plate driven pulsatile membrane pump, the Total Artificial Heart (TAH) ReinHeart, is currently under development at the Institute of Applied Medical Engineering of RWTH Aachen University.This paper presents the methodology of a fully coupled three-dimensional time-dependent Fluid Structure Interaction (FSI) simulation of the TAH using a commercial partitioned block-Gauss-Seidel coupling package. Partitioned coupling of the incompressible fluid with the slender flexible membrane as well as a high fluid/structure density ratio of about unity led inherently to a deterioration of the stability (‘artificial added mass instability’). The objective was to conduct a stable simulation with high accuracy of the pumping process. In order to achieve stability, a combined resistance and pressure outlet boundary condition as well as the interface artificial compressibility method was applied. An analysis of the contact algorithm and turbulence condition is presented. Independence tests are performed for the structural and the fluid mesh, the time step size and the number of pulse cycles. Because of the large deformation of the fluid domain, a variable mesh stiffness depending on certain mesh properties was specified for the fluid elements. Adaptive remeshing was avoided. Different approaches for the mesh stiffness function are compared with respect to convergence, preservation of mesh topology and mesh quality. The resulting mesh aspect ratios, mesh expansion factors and mesh orthogonalities are evaluated in detail. The membrane motion and flow distribution of the coupled simulations are compared with a top-view recording and stereo Particle Image Velocimetry (PIV) measurements, respectively, of the actual pump.

  4. Discovery of novel heart rate-associated loci using the Exome Chip

    DEFF Research Database (Denmark)

    van den Berg, Marten E; Warren, Helen R; Cabrera, Claudia P

    2017-01-01

    Resting heart rate is a heritable trait, and an increase in heart rate is associated with increased mortality risk. Genome-wide association study analyses have found loci associated with resting heart rate, at the time of our study these loci explained 0.9% of the variation. This study aims to di......) and fetal muscle samples by including our novel variants.Our findings advance the knowledge of the genetic architecture of heart rate, and indicate new candidate genes for follow-up functional studies....

  5. Correlation of heart rate and radionuclide index of left ventricular contraction and relaxation

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Hiroki; Nakagawa, Hiroaki; Inagaki, Suetsugu; Kubota, Yasushi; Nakagawa, Masao

    1990-01-01

    Since the cardiac function indices derived from radionuclide ventriculography (RNV) are considered to depend on the heart rate, we studied the relationship between systolic or diastolic indices and heart rates in patients with normal RNV and devised a method of correcting these indices according to the heart rate. For the systolic indices, the heart rate showed significant correlation with ET (r=-0.640), PER (r=0.791) and TPE (r=-0.401) but not with EF, 1/3 EF, MNSER or 1/3 MNSER. For the diastolic indices, the heart rate correlated well with FT (r=-0.938), RFT (r=-0.736), SFT (r=-0.803), 1/3 FF (r=-0.758), PFR (r=0.759), 1/3 PFR (r=0.742) and TPF (r=-0.389) but not with AFT, 1/3 MNDFR or AFF. These results indicate that many systolic and diastolic indices derived from RNV are affected by the heart rate, So when cardiac function is evaluated with the use of radionuclide indices, those which are independent of the heart rate should be used, or they should be corrected for the heart rate. As a method of correction, we proposed a rotating method obtained by manipulation of the regression equation of heart rates and indices. This new method is certain and easier to use when the correcting equations are set into a computer program. (author)

  6. Sleep Apnoea Detection in Single Channel ECGs by Analyzing Heart Rate Dynamics

    National Research Council Canada - National Science Library

    Zywietz, C

    2001-01-01

    .... Our analysis is based on spectral components of heart rate variability. Frequency analysis was performed using Fourier and wavelet transformation with appropriate application of the Hilbert transform...

  7. Digital Heart-Rate Variability Parameter Monitoring and Assessment ASIC.

    Science.gov (United States)

    Massagram, W; Hafner, N; Mingqi Chen; Macchiarulo, L; Lubecke, V M; Boric-Lubecke, O

    2010-02-01

    This paper describes experimental results for an application-specific integrated circuit (ASIC), designed for digital heart rate variability (HRV) parameter monitoring and assessment. This ASIC chip measures beat-to-beat (RR) intervals and stores HRV parameters into its internal memory in real time. A wide range of short-term and long-term ECG signals obtained from Physionet was used for testing. The system detects R peaks with millisecond accuracy, and stores up to 2 min of continuous RR interval data and up to 4 min of RR interval histogram. The prototype chip was fabricated in a 0.5 ¿m complementary metal-oxide semiconductor technology on a 3×3 mm(2) die area, with a measured dynamic power consumption of 10 ¿W and measured leakage current of 2.62 nA. The HRV monitoring system including this HRV ASIC, an analog-to-digital converter, and a low complexity microcontroller was estimated to consume 32.5 ¿V, which is seven times lower power than a stand-alone microcontroller performing the same functions. Compact size, low cost, and low power consumption make this chip suitable for a miniaturized portable HRV monitoring system.

  8. Determining cardiac vagal threshold from short term heart rate complexity

    Directory of Open Access Journals (Sweden)

    Hamdan Rami Abou

    2016-09-01

    Full Text Available Evaluating individual aerobic exercise capacity is fundamental in sports and exercise medicine but associated with organizational and instrumental effort. Here, we extract an index related to common performance markers, the aerobic and anaerobic thresholds enabling the estimation of exercise capacity from a conventional sports watch supporting beatwise heart rate tracking. Therefore, cardiac vagal threshold (CVT was determined in 19 male subjects performing an incremental maximum exercise test. CVT varied around the anaerobic threshold AnT with mean deviation of 7.9 ± 17.7 W. A high correspondence of the two thresholds was indicated by Bland-Altman plots with limits of agreement −27.5 W and 43.4 W. Additionally, CVT was strongly correlated AnT (rp = 0.86, p < 0.001 and reproduced this marker well (rc = 0.81. We conclude, that cardiac vagal threshold derived from compression entropy time course can be useful to assess physical fitness in an uncomplicated way.

  9. Heart rate variability in type 2 diabetes mellitus.

    Science.gov (United States)

    Stuckey, Melanie I; Petrella, Robert J

    2013-01-01

    Heart rate variability (HRV) is a noninvasive measure of cardiac autonomic modulation. Time and frequency domain measures have primarily been examined in patients with type 2 diabetes mellitus (T2D). Not only do frequency domain HRV parameters tend to be reduced in T2D, but healthy individuals with low HRV are also more likely to develop T2D. Furthermore, patients with T2D with low HRV have an increased prevalence of complications and risk of mortality compared with those with normal autonomic function. These findings provide support for the use of HRV as a risk indicator in T2D. Exercise is considered an important component to T2D prevention and treatment strategies. To date, few studies have examined the changes in HRV with exercise in T2D. One study showed changes in resting HRV, two studies showed changes in HRV during or following acute stressors, and one study showed no changes in HRV but improvements in baroreflex sensitivity. The most pronounced changes in HRV were realized following the exercise intervention with the greatest frequency of supervised exercise sessions and with the greatest intensity and duration of exercise bouts. These findings suggest that exercise following current American College of Sports Medicine/American Diabetes Association guidelines may be important in the prevention and treatment of T2D to improve autonomic function and reduce the risk of complications and mortality.

  10. Towards 24/7 continuous heart rate monitoring.

    Science.gov (United States)

    Tarniceriu, Adrian; Parak, Jakub; Renevey, Philippe; Nurmi, Marko; Bertschi, Mattia; Delgado-Gonzalo, Ricard; Korhonen, Ilkka

    2016-08-01

    Heart rate (HR) and HR variability (HRV) carry rich information about physical activity, mental and physical load, physiological status, and health of an individual. When combined with activity monitoring and personalized physiological modelling, HR/HRV monitoring may be used for monitoring of complex behaviors and impact of behaviors and external factors on the current physiological status of an individual. Optical HR monitoring (OHR) from wrist provides a comfortable and unobtrusive method for HR/HRV monitoring and is better adhered by users than traditional ECG electrodes or chest straps. However, OHR power consumption is significantly higher than that for ECG based methods due to the measurement principle based on optical illumination of the tissue. We developed an algorithmic approach to reduce power consumption of the OHR in 24/7 HR trending. We use continuous activity monitoring and a fast converging frequency domain algorithm to derive a reliable HR estimate in 7.1s (during outdoor sports, in average) to 10.0s (during daily life). The method allows >80% reduction in power consumption in 24/7 OHR monitoring when average HR monitoring is targeted, without significant reduction in tracking accuracy.

  11. Heart rate variability interventions for concussion and rehabilitation.

    Science.gov (United States)

    Conder, Robert L; Conder, Alanna A

    2014-01-01

    The study of heart rate variability (HRV) has emerged as an essential component of cardiovascular health, as well as a physiological mechanism by which one can increase the interactive communication between the cardiac and the neurocognitive systems (i.e., the body and the brain). It is well-established that lack of HRV implies cardiopathology, morbidity, reduced quality-of-life, and precipitous mortality. On the positive, optimal HRV has been associated with good cardiovascular health, autonomic nervous system (ANS) control, emotional regulation, and enhanced neurocognitive processing. In addition to health benefits, optimal HRV has been shown to improve neurocognitive performance by enhancing focus, visual acuity and readiness, and by promoting emotional regulation needed for peak performance. In concussed athletes and soldiers, concussions not only alter brain connectivity, but also alter cardiac functioning and impair cardiovascular performance upon exertion. Altered sympathetic and parasympathetic balance in the ANS has been postulated as a critical factor in refractory post concussive syndrome (PCS). This article will review both the pathological aspects of reduced HRV on athletic performance, as well as the cardiovascular and cerebrovascular components of concussion and PCS. Additionally, this article will review interventions with HRV biofeedback (HRV BFB) training as a promising and underutilized treatment for sports and military-related concussion. Finally, this article will review research and promising case studies pertaining to use of HRV BFB for enhancement of cognition and performance, with applicability to concussion rehabilitation.

  12. Heart Rate Variability Analysis in Patients with Allergic Rhinitis

    Directory of Open Access Journals (Sweden)

    Ming-Ying Lan

    2013-01-01

    Full Text Available Background. Very few studies investigate the role of the autonomic nervous system in allergic rhinitis. In this study, we evaluated the autonomic nervous system in allergic rhinitis patients using heart rate variability (HRV analysis. Methods. Eleven patients with allergic rhinitis and 13 healthy controls, aged between 19 and 40 years old, were enrolled in the study. Diagnosis of allergic rhinitis was based on clinical history, symptoms, and positive Phadiatop test. Electrocardiographic recordings on the sitting and supine positions were obtained for HRV analysis. Results. In the supine position, there were no significant statistical differences in very-low-frequency power (VLF, ≤0.04 Hz, low-frequency power (LF, 0.04–0.15 Hz, high-frequency power (HF, 0.15–0.40 Hz, and the ratio of LF to HF (LF/HF between the patient and control groups. The mean RR intervals significantly increased, while LF% and LF/HF significantly decreased in the patient group in the sitting position. Moreover, mean RR intervals, LF, and LF/HF, which were significantly different between the two positions in the control group, did not show a significant change with the posture change in the patient group. Conclusion. These suggest that patients with allergic rhinitis may have poor sympathetic modulation in the sitting position. Autonomic dysfunction may therefore play a role in the pathophysiology of allergic rhinitis.

  13. Heart rate variability: a tool to explore the sleeping brain?

    Directory of Open Access Journals (Sweden)

    Florian eChouchou

    2014-12-01

    Full Text Available Sleep is divided into two main sleep stages: 1 non-rapid eye movement sleep (non-REMS, characterized among others by reduced global brain activity; and 2 rapid eye movement sleep (REMS, characterized by global brain activity similar to that of wakefulness. Results of heart rate variability (HRV analysis, which is widely used to explore autonomic modulation, have revealed higher parasympathetic tone during normal non-REMS and a shift toward sympathetic predominance during normal REMS. Moreover, HRV analysis combined with brain imaging has identified close connectivity between autonomic cardiac modulation and activity in brain areas such as the amygdala and insular cortex during REMS, but no connectivity between brain and cardiac activity during non-REMS. There is also some evidence for an association between HRV and dream intensity and emotionality. Following some technical considerations, this review addresses how brain activity during sleep contributes to changes in autonomic cardiac activity, organized into three parts: 1 the knowledge on autonomic cardiac control, 2 differences in brain and autonomic activity between non-REMS and REMS, and 3 the potential of HRV analysis to explore the sleeping brain, and the implications for psychiatric disorders.

  14. Heart rates in hospitalized children by age and body temperature.

    Science.gov (United States)

    Daymont, Carrie; Bonafide, Christopher P; Brady, Patrick W

    2015-05-01

    Heart rate (HR) is frequently used by clinicians in the hospital to assess a patient's severity of illness and make treatment decisions. We sought to develop percentiles that characterize the relationship of expected HR by age and body temperature in hospitalized children and to compare these percentiles with published references in both primary care and emergency department (ED) settings. Vital sign data were extracted from electronic health records of inpatients temperature measurement pairs from each admission. Measurements from 60% of patients were used to derive the percentile curves, with the remainder used for validation. We compared our upper percentiles with published references in primary care and ED settings. We used 60,863 observations to derive the percentiles. Overall, an increase in body temperature of 1°C was associated with an increase of ∼ 10 beats per minute in HR, although there were variations across age and temperature ranges. For infants and young children, our upper percentiles were lower than in primary care and ED settings. For school-age children, our upper percentiles were higher. We characterized expected HR by age and body temperature in hospitalized children. These percentiles differed from references in primary care and ED settings. Additional research is needed to evaluate the performance of these percentiles for the identification of children who would benefit from further evaluation or intervention for tachycardia. Copyright © 2015 by the American Academy of Pediatrics.

  15. Peak heart rate decreases with increasing severity of acute hypoxia

    DEFF Research Database (Denmark)

    Lundby, C; Araoz, M; Van Hall, Gerrit

    2001-01-01

    , 459, and 404 mmHg) in a hypobaric chamber and while breathing 9% O(2) in N(2). These conditions were equivalent to altitudes of 3300, 4300, 5300, and 6300 m above sea level, respectively. At 4300 m, maximal exercise was also repeated after 4 and 8 h. Peak heart rate (HR) decreased from 191 (182......-202) (mean and range) at sea level to 189 (179-200), 182 (172-189), 175 (166-183), and 165 (162-169) in the acute hypoxic conditions. Peak HR did not decrease further after 4 and 8 h at 4300 m compared to the acute exposure at this altitude. Between barometric pressures of 518 and 355 mmHg (approximately...... 3300 and 6300 m), peak HR decreased linearly: peak HR(hypobaria) = peak HR(sea level) - 0.135 x [hypobaria(3100) - hypobaria (mmHg)]; or peak HR(altitude) = peak HR(sea level) - 0.15 x (altitude - 3100 m). This corresponds to approximately 1-beat x min(-1) reduction in peak HR for every 7-mmHg decrease...

  16. Heart Rate Variability Discriminates Competitive Levels in Professional Soccer Players.

    Science.gov (United States)

    Proietti, Riccardo; di Fronso, Selenia; Pereira, Lucas A; Bortoli, Laura; Robazza, Claudio; Nakamura, Fabio Y; Bertollo, Maurizio

    2017-06-01

    Heart rate variability (HRV) has been increasingly used to monitor team sports athletes. Besides the traditional time domain indices (i.e., the SD of successive RR intervals [SDNN] and the root mean square difference of successive normal RR intervals [RMSSD]), recently the use of the stress score (SS), which is an inverse function of the SD2 index derived from the Poincaré plot, and the sympathetic/parasympathetic ratio (S/PS) to monitor soccer players has been proposed. However, the reliability of these new indices and the ability of HRV to differentiate between soccer competitive levels are unknown. The aim of this study was to analyze the reliability of the different HRV-derived indices in professional soccer players during the competitive period and to compare HRV of professional soccer players from 3 teams of distinct competitive levels (i.e., Italian Second Division [2D], European League [EL], and Champions League [CL]). Fifty-four male professional soccer players from 3 different teams of 2 European countries (Italy and Germany) participated in the study. The intraclass correlation coefficient values of the HRV indices varied from 0.78 (very large) to 0.90 (near perfect). The coefficient of variation (CV) values for RMSSD and SDNN were all soccer players and is able to differentiate between international- and national-level players.

  17. Effect of propranolol on heart rate variability in hyperthyroidism.

    Science.gov (United States)

    Tankeu, Aurel T; Azabji-Kenfack, Marcel; Nganou, Chris-Nadège; Ngassam, Eliane; Kuate-Mfeukeu, Liliane; Mba, Camille; Dehayem, Mesmin Y; Mbanya, Jean-Claude; Sobngwi, Eugene

    2018-02-22

    We aimed to determine the effect of propanolol on heart rate variability (HRV) in hyperthyroidism before antithyroid treatment. This was a before and after study, on ten patients presenting overt hyperthyroidism naïve to treatment. In each patient, a resting electrocardiogram was done followed by estimation of cardiac autonomic dysfunction during five maneuvers (Ewing battery tests). Long term HRV measurement was done using 24 h ambulatory electrocardiographic recording. This automatically provided estimation of HRV using SDNN and RMSSD index, LF, HF, and HF/LF ratio. After baseline investigations, 40 mg of propanolol was given twice a day for 3 days and same parameters were measured after 72 h of treatment. Our patients were aged 40 ± 10 years. Propanolol significantly reduced RR and HR interval (669 ms vs 763 ms and 91 vs 79 bpm; p hyperthyroidism. Trial registration NCT03393728 "Retrospectively registered".

  18. Feature selection using genetic algorithms for fetal heart rate analysis

    International Nuclear Information System (INIS)

    Xu, Liang; Redman, Christopher W G; Georgieva, Antoniya; Payne, Stephen J

    2014-01-01

    The fetal heart rate (FHR) is monitored on a paper strip (cardiotocogram) during labour to assess fetal health. If necessary, clinicians can intervene and assist with a prompt delivery of the baby. Data-driven computerized FHR analysis could help clinicians in the decision-making process. However, selecting the best computerized FHR features that relate to labour outcome is a pressing research problem. The objective of this study is to apply genetic algorithms (GA) as a feature selection method to select the best feature subset from 64 FHR features and to integrate these best features to recognize unfavourable FHR patterns. The GA was trained on 404 cases and tested on 106 cases (both balanced datasets) using three classifiers, respectively. Regularization methods and backward selection were used to optimize the GA. Reasonable classification performance is shown on the testing set for the best feature subset (Cohen's kappa values of 0.45 to 0.49 using different classifiers). This is, to our knowledge, the first time that a feature selection method for FHR analysis has been developed on a database of this size. This study indicates that different FHR features, when integrated, can show good performance in predicting labour outcome. It also gives the importance of each feature, which will be a valuable reference point for further studies. (paper)

  19. Hypnosis in the Treatment of Major Depression: An Analysis of Heart Rate Variability.

    Science.gov (United States)

    Chen, Xiuwen; Yang, Rongqian; Ge, Lulu; Luo, Jie; Lv, Ruixue

    2017-01-01

    Hypnosis is an adjuvant treatment of major depression (MD). Heart rate variability (HRV) can assess the autonomic nervous system, which is associated with MD, and HRV is decreased in MD patients. There is a lack of research on HRV changes before, during, and after the use of hypnosis in MD patients. A total of 21 MD patients participated in this study, and 5-minute electrocardiograms were recorded before, during, and after hypnosis. Compared with the prehypnotic condition, HRV parameters significantly (p hypnosis treatment should bring some functional improvement to the autonomic nervous system. HRV is potentially a useful tool that quantifies the physiological impact of hypnosis treatment in MD patients.

  20. Heart rate variability and implication for sport concussion.

    Science.gov (United States)

    Bishop, Scott A; Dech, Ryan T; Guzik, Przemyslaw; Neary, J Patrick

    2017-11-16

    Finding sensitive and specific markers for sports-related concussion is both challenging and clinically important. Such biomarkers might be helpful in the management of patients with concussion (i.e. diagnosis, monitoring and risk prediction). Among many parameters, blood flow-pressure metrics and heart rate variability (HRV) have been used to gauge concussion outcomes. Reports on the relation between HRV and both acute and prolonged concussion recovery are conflicting. While some authors report on differences in the low-frequency (LF) component of HRV during postural manipulations and postexercise conditions, others observe no significant differences in various HRV measures. Despite the early success of using the HRV LF for concussion recovery, the interpretation of the LF is debated. Recent research suggests the LF power is a net effect of several intrinsic modulatory factors from both sympathetic and parasympathetic branches of the autonomic nervous system, vagally mediated baroreflex and even some respiratory influences at lower respiratory rate. There are only a few well-controlled concussion studies that specifically examine the contribution of the autonomic nervous system branches with HRV for concussion management. This study reviews the most recent HRV- concussion literature and the underlying HRV physiology. It also highlights cerebral blood flow studies related to concussion and the importance of multimodal assessment of various biological signals. It is hoped that a better understanding of the physiology behind HRV might generate cost-effective, repeatable and reliable protocols, all of which will improve the interpretation of HRV throughout concussion recovery. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  1. Heart rate variability and hear left ventricle hypertrophy in clean-up workers after Chernobyl accident with essential hypertension

    International Nuclear Information System (INIS)

    Khomazyuk, Yi.M.; Sidorenko, G.V.

    2004-01-01

    Correlation of heart rate variability (HRV) and hear left ventricle hypertrophy (LVH) in clean-up workers of Chernobyl accident with essential hypertension was estimated. Lowering of total HRV, parasympathetic and sympathetic activity associated with increased range of LVH was discovered

  2. Physiological and Behavioral Parameters of Infants' Categorization: Changes in Heart Rate and Duration of Examining across Trials

    Science.gov (United States)

    Elsner, Birgit; Pauen, Sabina; Jeschonek, Susanna

    2006-01-01

    This report investigates the relations between duration of examining and heart rate (HR) across several trials of an object-examination task. A total of N= 20 11-month-olds were familiarized with a sequence of 10 different exemplars from the same global category (animals or furniture) before they received an exemplar from the contrasting category…

  3. Accelerated high-frame-rate mouse heart cine-MRI using compressed sensing reconstruction.

    Science.gov (United States)

    Motaal, Abdallah G; Coolen, Bram F; Abdurrachim, Desiree; Castro, Rui M; Prompers, Jeanine J; Florack, Luc M J; Nicolay, Klaas; Strijkers, Gustav J

    2013-04-01

    We introduce a new protocol to obtain very high-frame-rate cinematographic (Cine) MRI movies of the beating mouse heart within a reasonable measurement time. The method is based on a self-gated accelerated fast low-angle shot (FLASH) acquisition and compressed sensing reconstruction. Key to our approach is that we exploit the stochastic nature of the retrospective triggering acquisition scheme to produce an undersampled and random k-t space filling that allows for compressed sensing reconstruction and acceleration. As a standard, a self-gated FLASH sequence with a total acquisition time of 10 min was used to produce single-slice Cine movies of seven mouse hearts with 90 frames per cardiac cycle. Two times (2×) and three times (3×) k-t space undersampled Cine movies were produced from 2.5- and 1.5-min data acquisitions, respectively. The accelerated 90-frame Cine movies of mouse hearts were successfully reconstructed with a compressed sensing algorithm. The movies had high image quality and the undersampling artifacts were effectively removed. Left ventricular functional parameters, i.e. end-systolic and end-diastolic lumen surface areas and early-to-late filling rate ratio as a parameter to evaluate diastolic function, derived from the standard and accelerated Cine movies, were nearly identical. Copyright © 2012 John Wiley & Sons, Ltd.

  4. Heart Disease Death Rates Among Blacks and Whites Aged ≥35 Years — United States, 1968–2015

    Science.gov (United States)

    Van Dyke, Miriam; Greer, Sophia; Odom, Erika; Schieb, Linda; Vaughan, Adam; Kramer, Michael; Casper, Michele

    2018-01-01

    Problem/Condition Heart disease is the leading cause of death in the United States. In 2015, heart disease accounted for approximately 630,000 deaths, representing one in four deaths in the United States. Although heart disease death rates decreased 68% for the total population from 1968 to 2015, marked disparities in decreases exist by race and state. Period Covered 1968–2015. Description of System The National Vital Statistics System (NVSS) data on deaths in the United States were abstracted for heart disease using diagnosis codes from the eighth, ninth, and tenth revisions of the International Classification of Diseases (ICD-8, ICD-9, and ICD-10) for 1968–2015. Population estimates were obtained from NVSS files. National and state-specific heart disease death rates for the total population and by race for adults aged ≥35 years were calculated for 1968–2015. National and state-specific black-white heart disease mortality ratios also were calculated. Death rates were age standardized to the 2000 U.S. standard population. Joinpoint regression was used to perform time trend analyses. Results From 1968 to 2015, heart disease death rates decreased for the total U.S. population among adults aged ≥35 years, from 1,034.5 to 327.2 per 100,000 population, respectively, with variations in the magnitude of decreases by race and state. Rates decreased for the total population an average of 2.4% per year, with greater average decreases among whites (2.4% per year) than blacks (2.2% per year). At the national level, heart disease death rates for blacks and whites were similar at the start of the study period (1968) but began to diverge in the late 1970s, when rates for blacks plateaued while rates for whites continued to decrease. Heart disease death rates among blacks remained higher than among whites for the remainder of the study period. Nationwide, the black-white ratio of heart disease death rates increased from 1.04 in 1968 to 1.21 in 2015, with large increases

  5. Heart rate variability in patients with systemic lupus erythematosus: a systematic review and methodological considerations.

    Science.gov (United States)

    Matusik, P S; Matusik, P T; Stein, P K

    2018-07-01

    Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.

  6. Relationship between obesity, negative affect and basal heart rate in predicting heart rate reactivity to psychological stress among adolescents.

    Science.gov (United States)

    Park, Andres E; Huynh, Pauline; Schell, Anne M; Baker, Laura A

    2015-08-01

    Reduced cardiovascular responses to psychological stressors have been found to be associated with both obesity and negative affect in adults, but have been less well studied in children and adolescent populations. These findings have most often been interpreted as reflecting reduced sympathetic nervous system response, perhaps associated with heightened baseline sympathetic activation among the obese and those manifesting negative affect. However, obesity and negative affect may themselves be correlated, raising the question of whether they both independently affect cardiovascular reactivity. The present study thus examined the separate effects of obesity and negative affect on both cardiovascular and skin conductance responses to stress (e.g., during a serial subtraction math task) in adolescents, while controlling for baseline levels of autonomic activity during rest. Both obesity and negative affect had independent and negative associations with cardiovascular reactivity, such that reduced stress responses were apparent for obese adolescents and those with high levels of negative affect. In contrast, neither obesity nor negative affect was related to skin conductance responses to stress, implicating specifically noradrenergic mechanisms rather than sympathetic mechanisms generally as being deficient. Moreover, baseline heart rate was unrelated to obesity in this sample, which suggests that heightened baseline of sympathetic activity is not necessary for the reduced cardiovascular reactivity to stress. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Effect of mibefradil on heart rate variability in patients with chronic heart failure

    NARCIS (Netherlands)

    Brouwer, J; de Kam, PJ; Haaksma, J; Crijns, HJGM; van Veldhuisen, DJ

    2000-01-01

    Background: Mibefradil was recently withdrawn from the market because of an unfavorable clinical profile in patients with chronic heart failure. Although drug interactions appear to play a role, other mechanisms such as proarrhythmia and autonomic deterioration could also be relevant. Chronic heart

  8. Impact of INTERMACS Profile on Clinical Outcomes for Patients Supported With the Total Artificial Heart.

    Science.gov (United States)

    Shah, Keyur B; Thanavaro, Kristin L; Tang, Daniel G; Quader, Mohammed A; Mankad, Anit K; Tchoukina, Inna; Thacker, Leroy R; Smallfield, Melissa C; Katlaps, Gundars; Hess, Michael L; Cooke, Richard H; Kasirajan, Vigneshwar

    2016-11-01

    Insufficient data delineate outcomes for Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile 1 patients with the total artificial heart (TAH). We studied 66 consecutive patients implanted with the TAH at our institution from 2006 through 2012 and compared outcome by INTERMACS profile. INTERMACS profiles were adjudicated retrospectively by a reviewer blinded to clinical outcomes. Survival after TAH implantation at 6 and 12 months was 76% and 71%, respectively. INTERMACS profile 1 patients had decreased 6-month survival on the device compared with those in profiles 2-4 (74% vs 95%, log rank: P = .015). For the 50 patients surviving to heart transplantation, the 1-year posttransplant survival was 82%. There was no difference in 1-year survival when comparing patients in the INTERMACS 1 profile with less severe profiles (79% vs 84%; log rank test P = .7; hazard ratio [confidence interval] 1.3 [0.3-4.8]). Patients implanted with the TAH as INTERMACS profile 1 had reduced survival to transplantation compared with less sick profiles. INTERMACS profile at the time of TAH implantation did not affect 1-year survival after heart transplantation. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. First clinical use of a bioprosthetic total artificial heart: report of two cases.

    Science.gov (United States)

    Carpentier, Alain; Latrémouille, Christian; Cholley, Bernard; Smadja, David M; Roussel, Jean-Christian; Boissier, Elodie; Trochu, Jean-Noël; Gueffet, Jean-Pierre; Treillot, Michèle; Bizouarn, Philippe; Méléard, Denis; Boughenou, Marie-Fazia; Ponzio, Olivier; Grimmé, Marc; Capel, Antoine; Jansen, Piet; Hagège, Albert; Desnos, Michel; Fabiani, Jean-Noël; Duveau, Daniel

    2015-10-17

    experienced a transient period of renal failure and a pericardial effusion requiring drainage, but otherwise uneventful postoperative course. He was discharged from the hospital on day 150 after surgery with a wearable system without technical assistance. After 4 months at home, the patient suffered low cardiac output. A change of C-TAH was attempted but the patient died of multiorgan failure. This preliminary experience could represent an important contribution to the development of total artificial hearts using bioprosthetic materials. CARMAT SA. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Heart rate recovery in elite Spanish male athletes.

    Science.gov (United States)

    Peinado, A B; Benito, P J; Barriopedro, M; Lorenzo, I; Maffulli, N; Calderón, F J

    2014-06-01

    During postexercise recovery, heart rate (HR) initially falls rapidly, followed by a period of slower decrease, until resting values are reached. The aim of the present work was to examine the differences in the recovery heart rate (RHR) between athletes engaged in static and dynamic sports. The study subjects were 294 federated sportsmen competing at the national and international level in sports classified using the criteria of Mitchell et al. as either prevalently static (N.=89) or prevalently dynamic (N.=205). Within the dynamic group, the subjects who practised the most dynamic sports were assigned to further subgroups: triathlon (N.=20), long distance running (N.=58), cycling (N.=28) and swimming (N.=12). All athletes were subjected to a maximum exertion stress test and their HR recorded at 1, 2, 3 and 4 min (RHR1,2,3,4) into the HR recovery period. The following indices of recovery (IR) were then calculated: IR1=(HRpeak-RHR1,2,3,4)/(HRmax-HRrest)*100, IR2=(HRpeak-RHR1,2,3,4)/(HRmax/HRpeak), and IR3=HRpeak-RHR1,2,3,4. The differences in the RHR and IR for the static and dynamic groups were examined using two way ANOVA. The RHR at minutes 2 (138.7±15.2 vs. 134.8±14.4 beats·min⁻¹) and 3 (128.5±15.2 vs. 123.3±14.4 beats·min⁻¹) were significantly higher for the static group (Group S) than the dynamic group (Group D), respectively. Significant differences were seen between Group D and S with respect to IR1 at minutes 1 (26.4±8.7 vs. 24.8±8.4%), 2 (43.8±8.1 vs. 41.5±7.8%), 3 (52.1±8.3 vs. 49.1±8%) and 4 (56.8±8.6 vs. 55.4±7.4%) of recovery. For IR2, significant differences were seen between the same groups at minutes 2 (59.7±12.5 vs. 55.9±10.8 beats·min⁻¹) and 3 (71.0±13.5 vs. 66.1±11.4 beats·min⁻¹) of recovery. Finally, for IR3, the only significant difference between Group D and S was recorded at minute 3 of recovery (72.2±12.5 vs. 66.2±11.5 beats·min⁻¹). This work provides information on RHR of a large population of elite

  11. Association Between Baseline Blood Pressures, Heart Rates, and Vasovagal Syncope in Children and Adolescents.

    Science.gov (United States)

    Adlakha, Himanshu; Gupta, Ruchi; Hassan, Romana; Kern, Jeffrey H

    2018-01-28

    Vasovagal syncope is the most common cause of syncope in children and adults, accounting for 50-66% of unexplained syncope. There are no studies establishing the relationship between syncope, baseline heart rate, and blood pressure. To identify a possible association between baseline blood pressure and heart rate with syncope. We conducted a questionnaire-based chart review study. A questionnaire was distributed to the guardian of children between eight and 18 years of age who attended the Pediatric Ambulatory Care Clinic at Flushing Hospital Medical Center. Based on the responses in the questionnaire, subjects were classified either as cases (positive for syncope) or controls (negative for syncope). Children and adolescents with neurological, cardiac, or any medical condition that can cause syncopal episodes were excluded from the study. Data collected from the questionnaire included age, gender, ethnicity, medical history, family history of syncope, and the amount of salt used in food. Anthropometric and vital signs for the current visit (height, weight, BMI, blood pressure, and heart rate) and vital signs from two previous visits were collected from electronic medical records. The data was analyzed using t-test and chi-square test with Microsoft Excel software (Microsoft Office Standard, v. 14, Microsoft; 2010); p<0.05 was considered significant. A total of 197 subjects were included in this study. There were 18 cases and 179 controls. Of the cases, (4/18) 22.2% were more likely to have a systolic blood pressure lower than the 10th percentile for their gender, age, and height as compared with controls (7/179) 3.9%, p = 0.003. The subjects with a history of syncope were more likely to add salt to their food (p = 0.004). There were no significant differences between cases and controls for age, gender, ethnicity between cases and controls for systolic blood pressure. No significant difference was observed between the heart rates of cases and controls. Children

  12. Reiki improves heart rate homeostasis in laboratory rats.

    Science.gov (United States)

    Baldwin, Ann Linda; Wagers, Christina; Schwartz, Gary E

    2008-05-01

    To determine whether application of Reiki to noise-stressed rats can reduce their heart rates (HRs) and blood pressures. In a previous study, we showed that exposure of rats to 90 dB white noise for 15 minutes caused their HRs and blood pressures to significantly increase. Reiki has been shown to significantly decrease HR and blood pressure in a small group of healthy human subjects. However, use of humans in such studies has the disadvantage that experimental interpretations are encumbered by the variable of belief or skepticism regarding Reiki. For that reason, noise-stressed rats were used as an animal model to test the efficacy of Reiki in reducing elevated HR and blood pressure. Three unrestrained, male Sprague-Dawley rats implanted with radiotelemetric transducers were exposed daily for 8 days to a 15-minute white noise regimen (90 dB). For the last 5 days, the rats received 15 minutes of Reiki immediately before the noise and during the noise period. The experiment was repeated on the same animals but using sham Reiki. The animals were housed in a quiet room in University of Arizona Animal Facility. Mean HRs and blood pressure were determined before Reiki/sham Reiki, during Reiki/sham Reiki, and during the noise in each case. Reiki, but not sham Reiki, significantly reduced HR compared to initial values. With Reiki, there was a high correlation between change in HR and initial HR, suggesting a homeostatic effect. Reiki, but not sham Reiki, significantly reduced the rise in HR produced by exposure of the rats to loud noise. Neither Reiki nor sham Reiki significantly affected blood pressure. Reiki is effective in modulating HR in stressed and unstressed rats, supporting its use as a stress-reducer in humans.

  13. Heart rate variability (HRV): an indicator of stress

    Science.gov (United States)

    Kaur, Balvinder; Durek, Joseph J.; O'Kane, Barbara L.; Tran, Nhien; Moses, Sophia; Luthra, Megha; Ikonomidou, Vasiliki N.

    2014-05-01

    Heart rate variability (HRV) can be an important indicator of several conditions that affect the autonomic nervous system, including traumatic brain injury, post-traumatic stress disorder and peripheral neuropathy [3], [4], [10] & [11]. Recent work has shown that some of the HRV features can potentially be used for distinguishing a subject's normal mental state from a stressed one [4], [13] & [14]. In all of these past works, although processing is done in both frequency and time domains, few classification algorithms have been explored for classifying normal from stressed RRintervals. In this paper we used 30 s intervals from the Electrocardiogram (ECG) time series collected during normal and stressed conditions, produced by means of a modified version of the Trier social stress test, to compute HRV-driven features and subsequently applied a set of classification algorithms to distinguish stressed from normal conditions. To classify RR-intervals, we explored classification algorithms that are commonly used for medical applications, namely 1) logistic regression (LR) [16] and 2) linear discriminant analysis (LDA) [6]. Classification performance for various levels of stress over the entire test was quantified using precision, accuracy, sensitivity and specificity measures. Results from both classifiers were then compared to find an optimal classifier and HRV features for stress detection. This work, performed under an IRB-approved protocol, not only provides a method for developing models and classifiers based on human data, but also provides a foundation for a stress indicator tool based on HRV. Further, these classification tools will not only benefit many civilian applications for detecting stress, but also security and military applications for screening such as: border patrol, stress detection for deception [3],[17], and wounded-warrior triage [12].

  14. Smartphone-Enabled Heart Rate Variability and Acute Mountain Sickness.

    Science.gov (United States)

    Mellor, Adrian; Bakker-Dyos, Josh; OʼHara, John; Woods, David Richard; Holdsworth, David A; Boos, Christopher J

    2018-01-01

    The autonomic system and sympathetic activation appears integral in the pathogenesis of acute mountain sickness (AMS) at high altitude (HA), yet a link between heart rate variability (HRV) and AMS has not been convincingly shown. In this study we investigated the utility of the smartphone-derived HRV score to predict and diagnose AMS at HA. Twenty-one healthy adults were investigated at baseline at 1400 m and over 10 days during a trek to 5140 m. HRV was recorded using the ithlete HRV device. Acute mountain sickness occurred in 11 subjects (52.4%) at >2650 m. HRV inversely correlated with AMS Scores (r = -0.26; 95% CI, -0.38 to -0.13: P HRV significantly fell at 3700, 4100, and 5140 m versus low altitude. HRV scores were lower in those with both mild (69.7 ± 14.0) and severe AMS (67.1 ± 13.1) versus those without AMS (77.5 ± 13.1; effect size n = 0.043: P = 0.007). The HRV score was weakly predictive of severe AMS (AUC 0.74; 95% CI, 0.58-0.89: P = 0.006). The change (delta) in the HRV Score (compared with baseline at 1400 m) was a moderate diagnostic marker of severe AMS (AUC 0.80; 95% CI, 0.70-0.90; P = 0.0004). A fall in the HRV score of >5 had a sensitivity of 83% and specificity of 60% to identify severe AMS (likelihood ratio 1.9). Baseline HRV at 1400 m was not predictive of either AMS at higher altitudes. The ithlete HRV score can be used to help in the identification of severe AMS; however, a baseline score is not predictive of future AMS development at HA.

  15. VASCULAR REMODELING AND HEART RATE VARIABILITY IN DIFFERENT ANTIHYPERTENSIVE THERAPIES

    Directory of Open Access Journals (Sweden)

    E. D. Golovanova

    2008-01-01

    Full Text Available Aim. To study the effect of the long-term antihypertensive monotherapy with indapamide (Arifon Retard, 1,5 mg/d, metoprolol tartrate (Egilok Retard, 50 mg/d and combined therapy with indapamide and perindopril (Noliprel Forte, 1 tab/d: perindopril 4 mg and indapamide 1,25 mg on pulse wave velocity (PWV, cardio-ankle vascular index (CAVI and the sympathetic system activity.Material and methods. 88 patients, aged 30-59 y.o. (32 normotensive patients, 56 with arterial hypertension [HT] of 1-2 grades were examined. Biological age (BA was determined by the linear regression and the vascular wall age (VWA was estimated with the use of volume sphygmography (“VaSera-1000”, “Fucuda Denshi”, Japan. 39 patients with HT were randomized into 3 parallel groups with studied therapies lasted for 6 months. PWV, CAVI of the vessels of elastic, muscular and mixed types, blood pressure, measured in upper and lower extremities and heart rate variability (HRV were determined before and at the end of the therapies.Results. BA and VWA were elevated in all of patients with HT as compared with normotensive patients. The reduction in PWV and CAVI of the vessels of elastic and mixed types, HRV increase were found in patients with Arifon Retard monotherapy. Monotherapy with metoprolol significantly improved HVR without any influence on the vascular remodeling. Noliprel Forte significantly decreased in blood pressure in the upper and lower extremities, PWV and CAVI of the vessels of all types, decreased in VWA and increased in parasympathetic drive.Conclusion. Long-term therapy with Arifon Retard and Noliprel Forte resulted in decrease in vascular remodeling and increase in HRV simultaneously with significant antihypertensive effect in patients with HT. Metoprolol low doses therapy resulted in normalization of autonomic drive independently on antihypertensive action.

  16. Heart Rate Response of Professional Musicians When Playing Music.

    Science.gov (United States)

    Vellers, Heather L; Irwin, Conor; Lightfoot, J T

    2015-06-01

    The primary aim was to determine the level of physiological stress evoked while playing music in a standing position as indicated by heart rate (HR) response. A secondary aim was to analyze the effect of music genre (classic rock, western, contemporary Christian, and metal rock) on the relative HR response. Lastly, we considered potential physiological initiators of the music-playing-induced HR response. HR response was monitored in 27 professional musicians (3 women, 24 men) between the ages of 21 and 67 yrs old during rehearsal and public performances. The percent maximal HR (%MHR) evoked was determined by taking a percentage of the age-predicted maximal HR for each musician and comparing the average %MHR in each genre during public and rehearsal events. The role of the potential initiators of these responses (e.g., number of years playing in public, event type, instrument type, tempo, etc.) was determined using multiple regression analyses. The overall average %MHR responses were 52 ± 5% and 59 ± 5% during rehearsal and public performances, respectively, with genre type having a significant effect on the HR response (p=0.01). Body mass index and tempo were each found to be significant contributors to the HR response while playing music (r²=0.506, p=0.001). Playing music professionally evokes considerable increases in HR response, with music genre influencing the level of the physiological response. We concluded that 50% of the HR response while playing music was associated with body mass index, music tempo, and instrument type.

  17. Improving Interprofessional Consistency in Electronic Fetal Heart Rate Interpretation.

    Science.gov (United States)

    Govindappagari, Shravya; Zaghi, Sahar; Zannat, Ferdous; Reimers, Laura; Goffman, Dena; Kassel, Irene; Bernstein, Peter S

    2016-07-01

    Objective To determine if mandatory online training in electronic fetal monitoring (EFM) improved agreement in documentation between obstetric care providers and nurses on labor and delivery. Methods Health care professionals working in obstetrics at our institution were required to complete a course on EFM interpretation. We performed a retrospective chart review of 701 charts including patients delivered before and after the introduction of the course to evaluate agreement among providers in their documentation of their interpretations of the EFM tracings. Results Agreement between provider and nurse documentation at the time of admission improved for variability and accelerations (variability: 91.1 vs. 98.3%, p < 0.001; and accelerations: 75.2 vs. 87.7%, p < 0.001). Similarly, agreement improved at the time of the last note prior to delivery for documentation of variability and accelerations (variability: 82.1 vs. 90.6%, p = 0.001; and accelerations: 56.7 vs. 68.6%, p = 0.0012). Agreement in interpretation of decelerations both at the time of admission and at the time of delivery increased (86.3 vs. 90.6%, p = 0.0787, and 56.7 vs. 61.1%, p = 0.2314, respectively) but was not significant. Conclusion An online EFM course can significantly improve consistency in multidisciplinary documentation of fetal heart rate tracing interpretation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Heart Rate Variability in Men with Erectile dysfunction

    Directory of Open Access Journals (Sweden)

    Ji Yong Lee

    2011-06-01

    Full Text Available Purpose The objective of this study is to investigate alteration of autonomic nervous system (ANS activity in patients suffering from erectile dysfunction (ED by comparing parameters of heart rate variability (HRV between men with ED and healthy subjects. Methods A retrospective review was performed on 40 ED patients (mean age, 46.0±8.49 years without any disease and 180 healthy control people (mean age, 44.4±7.83 years without ED in our institution from June 2008 to July 2010. And electrocardiographic signals were obtained to measure HRV parameters for both patients and controls in a resting state. Results For the time domain analysis, square root of the mean differences between successive RR intervals (RMSSD representing parasympathetic activity was lower in patients than controls although P-value was not statistically significant (P=0.060. For the frequency domain analysis, high frequency (HF representing parasympathetic activity was lower in patients than controls (P=0.232 and low frequency (LF representing mainly sympathetic activity was higher in patients than controls (P=0.416. Lastly, LF/HF ratio reflecting sympathetic/parasympathetic activity ratio was statistically higher in patients than controls (P=0.027. Conclusions Patients with ED exhibited different HRV parameters compared with normal controls. This suggests that the patients with ED may have some kind of imbalance in the ANS and it may be possible that general imbalance of the ANS is one of the causes of ED. Thus, HRV analysis may give valuable diagnostic information and serve as a rapid screening tool to evaluate altered ANS activity in patients with ED.

  19. The Effect of Sex on Heart Rate Variability at High Altitude.

    Science.gov (United States)

    Boos, Christopher John; Vincent, Emma; Mellor, Adrian; O'Hara, John; Newman, Caroline; Cruttenden, Richard; Scott, Phylip; Cooke, Mark; Matu, Jamie; Woods, David Richard

    2017-12-01

    There is evidence suggesting that high altitude (HA) exposure leads to a fall in heart rate variability (HRV) that is linked to the development of acute mountain sickness (AMS). The effects of sex on changes in HRV at HA and its relationship to AMS are unknown. HRV (5-min single-lead ECG) was measured in 63 healthy adults (41 men and 22 women) 18-56 yr of age at sea level (SL) and during a HA trek at 3619, 4600, and 5140 m, respectively. The main effects of altitude (SL, 3619 m, 4600 m, and 5140 m) and sex (men vs women) and their potential interaction were assessed using a factorial repeated-measures ANOVA. Logistic regression analyses were performed to assess the ability of HRV to predict AMS. Men and women were of similar age (31.2 ± 9.3 vs 31.7 ± 7.5 yr), ethnicity, and body and mass index. There was main effect for altitude on heart rate, SD of normal-to-normal (NN) intervals (SDNN), root mean square of successive differences (RMSSD), number of pairs of successive NN differing by >50 ms (NN50), NN50/total number of NN, very low-frequency power, low-frequency (LF) power, high-frequency (HF) power, and total power (TP). The most consistent effect on post hoc analysis was reduction in these HRV measures between 3619 and 5140 m at HA. Heart rate was significantly lower and SDNN, RMSSD, LF power, HF power, and TP were higher in men compared with women at HA. There was no interaction between sex and altitude for any of the HRV indices measured. HRV was not predictive of AMS development. Increasing HA leads to a reduction in HRV. Significant differences between men and women emerge at HA. HRV was not predictive of AMS.

  20. Musculoskeletal Disorders study in damming construction workers by Fox equation and measurement heart rate at work

    Directory of Open Access Journals (Sweden)

    L. Gheibi

    2008-04-01

    Full Text Available Background and aims   Musculoskeletal Disorders are prevalent in construction workers in comparison to other working groups. These workers in damming construction worked at awkward  postures for long times, so ergonomic assessment of jobs was important.   Methods   This is a descriptive-analytical cross sectional study that conducted in 2008 on a random sample of workers of damming construction in Takab city (110 men who were assessed by Nordic Musculoskeletal questionnaire and digital indicator for heart measurement. To estimate  Vo2max consumption Fox equation was used and data were analyzed by SPSS software.   Results   The average of total time of worked was 36.6 86.8 months. Results showed that the  most prevalent (%55.5 MSDs was low back pain which was positively related with type of job,  the number of standing and sitting posotions at work, total time of work, age, smoking, level of   education, weight,Vo2max that estimated by Fox Equation, and heart rate at working (P<0.05.   Conclusion   The results of this study reveal that prevalence rate of musculoskeletal disorders are high among damming construction workers, and heart rate and Vo2max consumption increases with increase in work load. Therefore, optimal physiological conditions should be considered  and physical capacity be measured. Prior to employment of workers approperiate corrections are  warranted      

  1. Early in vivo experience with the pediatric continuous-flow total artificial heart.

    Science.gov (United States)

    Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Kuban, Barry D; Gao, Shengqiang; Dessoffy, Raymond; Fukamachi, Kiyotaka

    2018-03-30

    Heart transplantation in infants and children is an accepted therapy for end-stage heart failure, but donor organ availability is low and always uncertain. Mechanical circulatory support is another standard option, but there is a lack of intracorporeal devices due to size and functional range. The purpose of this study was to evaluate the in vivo performance of our initial prototype of a pediatric continuous-flow total artificial heart (P-CFTAH), comprising a dual pump with one motor and one rotating assembly, supported by a hydrodynamic bearing. In acute studies, the P-CFTAH was implanted in 4 lambs (average weight: 28.7 ± 2.3 kg) via a median sternotomy under cardiopulmonary bypass. Pulmonary and systemic pump performance parameters were recorded. The experiments showed good anatomical fit and easy implantation, with an average aortic cross-clamp time of 98 ± 18 minutes. Baseline hemodynamics were stable in all 4 animals (pump speed: 3.4 ± 0.2 krpm; pump flow: 2.1 ± 0.9 liters/min; power: 3.0 ± 0.8 W; arterial pressure: 68 ± 10 mm Hg; left and right atrial pressures: 6 ± 1 mm Hg, for both). Any differences between left and right atrial pressures were maintained within the intended limit of ±5 mm Hg over a wide range of ratios of systemic-to-pulmonary vascular resistance (0.7 to 12), with and without pump-speed modulation. Pump-speed modulation was successfully performed to create arterial pulsation. This initial P-CFTAH prototype met the proposed requirements for self-regulation, performance, and pulse modulation. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  2. Description, evaluation and clinical decision making according to various fetal heart rate patterns. Inter-observer and regional variability

    DEFF Research Database (Denmark)

    Lidegaard, O; Bøttcher, L M; Weber, Tom

    1992-01-01

    departments, especially between departments far apart. It is concluded that we still need a scientific clarification of which specific heart rate changes are the best predictors of fetal stress. Artificial intelligence programs for interpreting fetal cardiotocograms and ECG signals constitute one promising......At 10 Danish obstetrical departments, 116 residents (42 senior and 74 junior) participated in a study to assess inter-observer and regional variability in the description and evaluation of and clinical decision regarding 11 fetal heart rate patterns. The 11 traces included normal as well...... as pathological patterns, and normal as well as clinically asphyxiated babies. Five antepartum and six intrapartum patterns were included. A total of 1,276 descriptions and evaluations were obtained. The degree of agreement in description of fetal heart rate changes was high regarding the baseline...

  3. Sensitivity analysis and comparison of two methods of using heart rate to represent energy expenditure during walking.

    Science.gov (United States)

    Karimi, Mohammad Taghi

    2015-01-01

    Heart rate is an accurate and easy to use method to represent the energy expenditure during walking, based on physiological cost index (PCI). However, in some conditions the heart rate during walking does not reach to a steady state. Therefore, it is not possible to determine the energy expenditure by use of the PCI index. The total heart beat index (THBI) is a new method to solve the aforementioned problem. The aim of this research project was to find the sensitivity of both the physiological cost index (PCI) and total heart beat index (THBI). Fifteen normal subjects and ten patients with flatfoot disorder and two subjects with spinal cord injury were recruited in this research project. The PCI and THBI indexes were determined by use of heart beats with respect to walking speed and total distance walked, respectively. The sensitivity of PCI was more than that of THBI index in the three groups of subjects. Although the PCI and THBI indexes are easy to use and reliable parameters to represent the energy expenditure during walking, their sensitivity is not high to detect the influence of some orthotic interventions, such as use of insoles or using shoes on energy expenditure during walking.

  4. The Influence of Motor Impairment on Autonomic Heart Rate Modulation among Children with Cerebral Palsy

    Science.gov (United States)

    Zamuner, Antonio Roberto; Cunha, Andrea Baraldi; da Silva, Ester; Negri, Ana Paola; Tudella, Eloisa; Moreno, Marlene Aparecida

    2011-01-01

    The study of heart rate variability is an important tool for a noninvasive evaluation of the neurocardiac integrity. The present study aims to evaluate the autonomic heart rate modulation in supine and standing positions in 12 children diagnosed with cerebral palsy and 16 children with typical motor development (control group), as well as to…

  5. Resemblances of Parents and Twins in Sport Participation and Heart Rate

    NARCIS (Netherlands)

    Boomsma, D.I.; van den Bree, M.B.; Orlebeke, J.F.; Molenaar, P.C.M.

    1989-01-01

    A model to analyze resemblances of twins and parents using LISREL is outlined and applied to sports participation and heart-rate data. Sports participation and heart rate were measured in 44 monozygotic and 46 dizygotic adolescent twin pairs and in their parents. Genetic factors influence variation

  6. Identification of heart rate-associated loci and their effects on cardiac conduction and rhythm disorders

    NARCIS (Netherlands)

    den Hoed, M.A.H.; Eijgelsheim, M.; Esko, T.; Brundel, B.J.; Peal, D.S.; Evans, D.M.; Nolte, I.M.; Segrè, A.V.; Holm, H.; Handsaker, R.E.; Westra, H.J.; Johnson, T.; Isaacs, A.; Yang, L.; Lundby, A.; Zhao, J.H.; Kim, Y.J.; Go, M.J.; Almgren, P.; Bochud, M.; Boucher, G.; Cornelis, M.C.; Gudbjartsson, D.F.; Hadley, D.; van der Harst, P.; Hayward, C.; den Heijer, M.; Igl, W.; Jackson, A.U.; Kutalik, Z.; Luan, J.; Kemp, J.P.; Kristiansson, K.; Ladenvall, C.; Lorentzon, M.; Montasser, M.E.; Njajou, O.T.; O'Reilly, P.F.; Padmanabhan, S.; St Pourcain, B.; Rankinen, T.; Salo, P.; Tanaka, T.; Timpson, N.J.; Vitart, V.; Waite, L.; Wheeler, W.; Zhang, W.; Draisma, H.H.M.; Feitosa, M.F.; Kerr, K.F.; Lind, P.A.; Mihailov, E.; Onland-Moret, N.C.; Song, C.; Weedon, M.N.; Xie, W.; Yengo, L.; Absher, D.; Albert, C.M.; Alonso, A.; Arking, D.E.; de Bakker, P.I.; Balkau, B.; Barlassina, C.; Benaglio, P.; Bis, J.C.; Bouatia-Naji, N.; Brage, S.; Chanock, S.J.; Chines, P.S.; Chung, M.; Darbar, D.; Dina, C.; Dörr, M.; Elliott, P.; Felix, S.B.; Fischer, K.; Fuchsberger, C.; de Geus, E.J.C.; Goyette, P.; Gudnason, V.; Harris, T.B.; Hartikainen, A.L.; Havulinna, A.S.; Heckbert, S.R.; Hicks, A.A.; Hofman, A.; Holewijn, S.; Hoogstra-Berends, F.; Hottenga, J.J.; Jensen, M.K.; Johansson, A.; Junttila, J.; Kääb, S.; Kanon, B.; Ketkar, S.; Khaw, K.T.; Knowles, J.W.; Kooner, A.S.; Kors, J.A.; Kumari, M.; Milani, L.; Laiho, P.; Lakatta, E.G.; Langenberg, C.; Leusink, M.; Liu, Y.; Luben, R.N.; Lunetta, K.L.; Lynch, S.N.; Markus, M.R.; Marques-Vidal, P.; Mateo Leach, I.; McArdle, W.L.; McCarroll, S.A.; Medland, S.E.; Miller, K.A.; Montgomery, G.W.; Morrison, A.C.; Müller-Nurasyid, M.; Navarro, P.; Nelis, M.; O'Connell, J.R.; O'Donnell, C.J.; Ong, K.K.; Newman, A.B.; Peters, A.; Polasek, O.; Pouta, A.; Pramstaller, P.P.; Psaty, B.M.; Rao, D.C.; Ring, S.M.; Rossin, E.J.; Rudan, D.; Sanna, S.; Scott, R.A.; Sehmi, J.S.; Sharp, S.; Shin, J.T.; Singleton, A.B.; Smith, A.V.; Soranzo, N.; Spector, T.D.; Stewart, C.; Stringham, H.M.; Tarasov, K.V.; Uitterlinden, A.G.; Vandenput, L.; Hwang, S.J.; Whitfield, J.B.; Wijmenga, C.; Wild, S.H.; Willemsen, G.; Wilson, J.F.; Witteman, J.C.; Wong, A.; Wong, Q.; Jamshidi, Y.; Zitting, P.; Boer, J.M.; Boomsma, D.I.; Borecki, I.B.; van Duijn, C.M.; Ekelund, U.; Forouhi, N.G.; Froguel, P.; Hingorani, A.D.; Ingelsson, E.; Kivimaki, M.; Kronmal, R.A.; Kuh, D; Lind, L.; Martin, N.G.; Oostra, B.A.; Pedersen, N.L.; Quertermous, T.; Rotter, J.I.; van der Schouw, Y.T.; Verschuren, W.M.; Walker, M.; Albanes, D.; Arnar, D.O.; Assimes, T.L.; Bandinelli, S.; Boehnke, M.; de Boer, R.A.; Bouchard, C.; Caulfield, W.L.; Chambers, J.C.; Curhan, G.; Cusi, D.; Eriksson, J.; Ferrucci, L.; van Gilst, W.H.; Glorioso, N.; de Graaf, J.; Groop, L.; Gyllensten, U.; Hsueh, W.C.; Hu, F.B.; Huikuri, H.V.; Hunter, D.J.; Iribarren, C.; Isomaa, B.; Järvelin, M.R.; Jula, A.; Kähönen, M.; Kiemeney, L.A.; van der Klauw, M.M.; Kooner, J.S.; Kraft, P.; Iacoviello, L.; Lehtimäki, T.; Lokki, M.L.; Mitchell, B.D.; Navis, G.; Nieminen, M.S.; Ohlsson, C.; Poulter, N.R.; Qi, L.; Raitakari, O.T.; Rimm, E.B.; Rioux, J.D.; Rizzi, F.; Rudan, I.; Salomaa, V.; Sever, P.S.; Shields, D.C.; Shuldiner, A.R.; Sinisalo, J.; Stanton, A.V.; Stolk, R.P.; Strachan, D.P.; Tardif, J.C.; Thorsteinsdottir, U.; Tuomilehto, J.; van Veldhuisen, D.J.; Virtamo, J.; Viikari, J.; Vollenweider, P.; Waeber, G.; Widen, E.; Cho, Y.S.; Olsen, J.V.; Visscher, P.M.; Willer, C.J.; Franke, L; Erdmann, J.; Thompson, J.R.; Pfeufer, A.; Sotoodehnia, N.; Newton-Cheh, C.; Ellinor, P.T.; Stricker, B.H.C.; Metspalu, A.; Perola, M.; Beckmann, J.S.; Smith, G.D.; Stefansson, K.; Wareham, N.J.; Munroe, P.B.; Sibon, O.C.M.; Milan, D.J.; Snieder, H.; Samani, N.J.; Loos, R.J.

    2013-01-01

    Elevated resting heart rate is associated with greater risk of cardiovascular disease and mortality. In a 2-stage meta-analysis of genome-wide association studies in up to 181,171 individuals, we identified 14 new loci associated with heart rate and confirmed associations with all 7 previously

  7. iHeartrate: a heart rate controlled in-flight music recommendation system

    NARCIS (Netherlands)

    Liu, H.; Hu, J.; Rauterberg, G.W.M.; Spink, A.J.; Grieco, O.E.; Krips, L.W.S.; Loijens, L.P.J.J.; Noldus, xx; Zimmerman, P.H.

    2010-01-01

    Travel by air, especially long distance, the enclosed environment of the aircraft cabin causes discomfort and even stress to flight passengers. In this paper, we present a new heart rate controlled music recommendation system. Heart rate is used as a stress indicator. If the user is stressed and

  8. Effects of vasoactive intestinal polypeptide on heart rate in relation to vagal cardioacceleration in conscious dogs

    NARCIS (Netherlands)

    Roossien, A; Brunstig, J.R; Nijmeijer, A; Zaagsma, Hans; Zijlstra, W.G

    Objective: The vagal cardiac accelerator (VCA) system takes part in the nervous control of the heart rate. In the present study we tried to adduce evidence that vasoactive intestinal polypeptide (VLP) contributes to vagally induced cardioacceleration. Methods: The effect of VIP on heart rate and

  9. Neighborhood blight, stress, and health: a walking trial of urban greening and ambulatory heart rate

    Science.gov (United States)

    Eugenia C. South; Michelle C. Kondo; Rose A. Cheney; Charles C. Branas

    2015-01-01

    We measured dynamic stress responses using ambulatory heart rate monitoring as participants in Philadelphia, Pennsylvania walked past vacant lots before and after a greening remediation treatment of randomly selected lots. Being in view of a greened vacant lot decreased heart rate significantly more than did being in view of a nongreened vacant lot or not in view of...

  10. Variation in heart rate during submaximal exercise: Implications for monitoring training : Implications for monitoring training

    NARCIS (Netherlands)

    Lamberts, R.P.; Lemmink, K.A.P.M.; Durandt, J.J.; Lambert, M.I.

    2004-01-01

    A change in heart rate at a controlled submaximal exercise intensity is used as a marker of training status. However, the standard error of measurement has not been studied systematically, and therefore a change in heart rate, which can be considered relevant, has not been determined. Forty-four

  11. Paradoxical response to an emotional task: Trait characteristics and heart-rate dynamics

    NARCIS (Netherlands)

    Balocchia, R.; Varanini, M.; Paoletti, G.; Mecacci, G.; Santarcangelo, E.L.

    2015-01-01

    The present study evaluated the heart-rate dynamics of subjects reporting decreased (responders) or paradoxically increased relaxation (nonresponders) at the end of a threatening movie. Heart-rate dynamics were characterized by indices extracted through recurrence quantification analysis (RQA) and

  12. Heart Rates of Elementary Physical Education Students during the Dancing Classrooms Program

    Science.gov (United States)

    Nelson, Larry; Evans, Melissa; Guess, Wendy; Morris, Mary; Olson, Terry; Buckwalter, John

    2011-01-01

    We examined how different types of dance activities, along with their duration, influenced heart rate responses among fifth-grade physical education students (N = 96) who participated in the Dancing Classrooms program. Results indicated that the overall Dancing Classrooms program elicits a moderate cardiovascular heart rate response (M = 124.4…

  13. Elevated resting heart rate, physical fitness and all-cause mortality

    DEFF Research Database (Denmark)

    Jensen, Magnus Thorsten; Suadicani, Poul; Hein, Hans Ole

    2013-01-01

    To examine whether elevated resting heart rate (RHR) is an independent risk factor for mortality or a mere marker of physical fitness (VO2Max).......To examine whether elevated resting heart rate (RHR) is an independent risk factor for mortality or a mere marker of physical fitness (VO2Max)....

  14. Physiological Study on the Relation of Heart Rate Variability in Ageing and Thyroid Hormone Disorder

    Directory of Open Access Journals (Sweden)

    Elsayed A. M. Shokr

    2016-04-01

    Full Text Available The present study aimed to investigate whether cardiac autonomic dysfunction in aging human might be related to an underlying thyroid disturbance. ageing has been associated with hypothyroidism and cardiac autonomic dysfunction. On the basis of body mass index (BMI, 150 patients were grouped into three groups (n = 50 48 years ± 2, 55 years ± 2 and 63 years ± 2. Electrocardiogram was recorded using PowerLab system and the time and frequency domain measures of heart rate variability (HRV were calculated. Fasting blood samples were drawn for measurement of serum thyroid stimulating hormone (TSH, total thyroxin (T4 and total triiodothyronine (T3 concentrations. The levels of TSH, T4 and T3 were not significantly different between the groups. The frequency domain HRV parameter reflecting parasympathetic tone (high-frequency normalized units, HFnu was significantly reduced in aging third groups group. The parameters which reflect sympathetic activation (Heart rate, low-frequency normalized units; LFnu and the LF/HF ratio were significantly increased in the aging group. HFnu was significantly and negatively correlated with age, whereas LFnu and LF/HF ratio were significantly and positively correlated with the above mentioned parameters. No significant relationships were noted between the HRV parameters and the levels of TSH or thyroid hormones. Cardiac autonomic dysfunction in aging human is not linked with underlying thyroid disturbance.

  15. Rate control management of atrial fibrillation: may a mathematical model suggest an ideal heart rate?

    Directory of Open Access Journals (Sweden)

    Matteo Anselmino

    Full Text Available Despite the routine prescription of rate control therapy for atrial fibrillation (AF, clinical evidence demonstrating a heart rate target is lacking. Aim of the present study was to run a mathematical model simulating AF episodes with a different heart rate (HR to predict hemodynamic parameters for each situation.The lumped model, representing the pumping heart together with systemic and pulmonary circuits, was run to simulate AF with HR of 50, 70, 90, 110 and 130 bpm, respectively.Left ventricular pressure increased by 57%, from 33.92±37.56 mmHg to 53.15±47.56 mmHg, and mean systemic arterial pressure increased by 27%, from 82.66±14.04 mmHg to 105.3±7.6 mmHg, at the 50 and 130 bpm simulations, respectively. Stroke volume (from 77.45±8.50 to 39.09±8.08 mL, ejection fraction (from 61.10±4.40 to 39.32±5.42% and stroke work (SW, from 0.88±0.04 to 0.58±0.09 J decreased by 50, 36 and 34%, at the 50 and 130 bpm simulations, respectively. In addition, oxygen consumption indexes (rate pressure product - RPP, tension time index per minute - TTI/min, and pressure volume area per minute - PVA/min increased from the 50 to the 130 bpm simulation, respectively, by 186% (from 5598±1939 to 15995±3219 mmHg/min, 56% (from 2094±265 to 3257±301 mmHg s/min and 102% (from 57.99±17.90 to 117.4±26.0 J/min. In fact, left ventricular efficiency (SW/PVA decreased from 80.91±2.91% at 50 bpm to 66.43±3.72% at the 130 bpm HR simulation.Awaiting compulsory direct clinical evidences, the present mathematical model suggests that lower HRs during permanent AF relates to improved hemodynamic parameters, cardiac efficiency, and lower oxygen consumption.

  16. Rate control management of atrial fibrillation: may a mathematical model suggest an ideal heart rate?

    Science.gov (United States)

    Anselmino, Matteo; Scarsoglio, Stefania; Camporeale, Carlo; Saglietto, Andrea; Gaita, Fiorenzo; Ridolfi, Luca

    2015-01-01

    Despite the routine prescription of rate control therapy for atrial fibrillation (AF), clinical evidence demonstrating a heart rate target is lacking. Aim of the present study was to run a mathematical model simulating AF episodes with a different heart rate (HR) to predict hemodynamic parameters for each situation. The lumped model, representing the pumping heart together with systemic and pulmonary circuits, was run to simulate AF with HR of 50, 70, 90, 110 and 130 bpm, respectively. Left ventricular pressure increased by 57%, from 33.92±37.56 mmHg to 53.15±47.56 mmHg, and mean systemic arterial pressure increased by 27%, from 82.66±14.04 mmHg to 105.3±7.6 mmHg, at the 50 and 130 bpm simulations, respectively. Stroke volume (from 77.45±8.50 to 39.09±8.08 mL), ejection fraction (from 61.10±4.40 to 39.32±5.42%) and stroke work (SW, from 0.88±0.04 to 0.58±0.09 J) decreased by 50, 36 and 34%, at the 50 and 130 bpm simulations, respectively. In addition, oxygen consumption indexes (rate pressure product - RPP, tension time index per minute - TTI/min, and pressure volume area per minute - PVA/min) increased from the 50 to the 130 bpm simulation, respectively, by 186% (from 5598±1939 to 15995±3219 mmHg/min), 56% (from 2094±265 to 3257±301 mmHg s/min) and 102% (from 57.99±17.90 to 117.4±26.0 J/min). In fact, left ventricular efficiency (SW/PVA) decreased from 80.91±2.91% at 50 bpm to 66.43±3.72% at the 130 bpm HR simulation. Awaiting compulsory direct clinical evidences, the present mathematical model suggests that lower HRs during permanent AF relates to improved hemodynamic parameters, cardiac efficiency, and lower oxygen consumption.

  17. Aggressive behavior: an alternative model of resting heart rate and sensation seeking.

    Science.gov (United States)

    Wilson, Laura C; Scarpa, Angela

    2014-01-01

    Low resting heart rate is a well-replicated biological correlate of aggression, and sensation seeking is frequently cited as the underlying causal explanation. However, little empirical evidence supports this mediating relationship. Furthermore, the biosocial model of violence and social push theory suggest sensation seeking may moderate the relationship between heart rate and aggression. In a sample of 128 college students (82.0% White; 73.4% female), the current study tested a moderation model as an alternative relationship between resting heart rate and sensation seeking in regard to aggression. Overall, the findings partially supported an interaction effect, whereby the relationship between heart rate and aggression was moderated by sensation seeking. Specifically, the oft-noted relationship between low resting heart rate and increased aggression was found, but only for individuals with low levels of sensation seeking. If replication supports this finding, the results may better inform prevention and intervention work. © 2013 Wiley Periodicals, Inc.

  18. Prototype Development of an Implantable Compliance Chamber for a Total Artificial Heart.

    Science.gov (United States)

    Schmitz, Stephanie; Unthan, Kristin; Sedlaczek, Marc; Wald, Felix; Finocchiaro, Thomas; Spiliopoulos, Sotirios; Koerfer, Reiner; Steinseifer, Ulrich

    2017-02-01

    At our institute a total artificial heart is being developed. It is directly actuated by a linear drive in between two ventricles, which comprise membranes to separate the drive and blood flow. A compliance chamber (CC) is needed to reduce pressure peaks in the ventricles and to increase the pump capacity. Therefore, the movement of the membrane is supported by applying a negative pressure to the air volume inside the drive unit. This study presents the development of the implantable CC which is connected to the drive unit of the total artificial hearts (TAH). The anatomical fit of the CC is optimized by analyzing CT data and adapting the outer shape to ensure a proper fit. The pressure peaks are reduced by the additional volume and the flexible membrane of the CC. The validation measurements of change in pressure peaks and flow are performed using the complete TAH system connected to a custom mock circulation loop. Using the CC, the pressure peaks could be damped below 5 mm Hg in the operational range. The flow output was increased by up to 14.8% on the systemic side and 18.2% on the pulmonary side. The described implantable device can be used for upcoming chronic animal trials. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Conventional heart rate variability analysis of ambulatory electrocardiographic recordings fails to predict imminent ventricular fibrillation

    Science.gov (United States)

    Vybiral, T.; Glaeser, D. H.; Goldberger, A. L.; Rigney, D. R.; Hess, K. R.; Mietus, J.; Skinner, J. E.; Francis, M.; Pratt, C. M.

    1993-01-01

    OBJECTIVES. The purpose of this report was to study heart rate variability in Holter recordings of patients who experienced ventricular fibrillation during the recording. BACKGROUND. Decreased heart rate variability is recognized as a long-term predictor of overall and arrhythmic death after myocardial infarction. It was therefore postulated that heart rate variability would be lowest when measured immediately before ventricular fibrillation. METHODS. Conventional indexes of heart rate variability were calculated from Holter recordings of 24 patients with structural heart disease who had ventricular fibrillation during monitoring. The control group consisted of 19 patients with coronary artery disease, of comparable age and left ventricular ejection fraction, who had nonsustained ventricular tachycardia but no ventricular fibrillation. RESULTS. Heart rate variability did not differ between the two groups, and no consistent trends in heart rate variability were observed before ventricular fibrillation occurred. CONCLUSIONS. Although conventional heart rate variability is an independent long-term predictor of adverse outcome after myocardial infarction, its clinical utility as a short-term predictor of life-threatening arrhythmias remains to be elucidated.

  20. Behavioral correlates of heart rates of free-living Greater White-fronted Geese

    Science.gov (United States)

    Ely, Craig R.; Ward, D.H.; Bollinger, K.S.

    1999-01-01

    We simultaneously monitored the heart rate and behavior of nine free-living Greater White-fronted Geese (Anser albifrons) on their wintering grounds in northern California. Heart rates of wild geese were monitored via abdominally-implanted radio transmitters with electrodes that received electrical impulses of the heart and emitted a radio signal with each ventricular contraction. Post-operative birds appeared to behave normally, readily rejoining flocks and flying up to 15 km daily from night-time roost sites to feed in surrounding agricultural fields. Heart rates varied significantly among individuals and among behaviors, and ranged from less than 100 beats per minute (BPM) during resting, to over 400 BPM during flight. Heart rates varied from 80 to 140 BPM during non-strenuous activities such as walking, feeding, and maintenance activities, to about 180 BPM when birds became alert, and over 400 BPM when birds were startled, even if they did not take flight. Postflight heart rate recovery time averaged postures, as heart rates were context-dependent, and were highest in initial encounters among individuals. Instantaneous measures of physiological parameters, such as heart rate, are often better indicators of the degree of response to external stimuli than visual observations and can be used to improve estimates of energy expenditure based solely on activity data.

  1. On heart rate variability and autonomic activity in homeostasis and in systemic inflammation.

    Science.gov (United States)

    Scheff, Jeremy D; Griffel, Benjamin; Corbett, Siobhan A; Calvano, Steve E; Androulakis, Ioannis P

    2014-06-01

    Analysis of heart rate variability (HRV) is a promising diagnostic technique due to the noninvasive nature of the measurements involved and established correlations with disease severity, particularly in inflammation-linked disorders. However, the complexities underlying the interpretation of HRV complicate understanding the mechanisms that cause variability. Despite this, such interpretations are often found in literature. In this paper we explored mathematical modeling of the relationship between the autonomic nervous system and the heart, incorporating basic mechanisms such as perturbing mean values of oscillating autonomic activities and saturating signal transduction pathways to explore their impacts on HRV. We focused our analysis on human endotoxemia, a well-established, controlled experimental model of systemic inflammation that provokes changes in HRV representative of acute stress. By contrasting modeling results with published experimental data and analyses, we found that even a simple model linking the autonomic nervous system and the heart confound the interpretation of HRV changes in human endotoxemia. Multiple plausible alternative hypotheses, encoded in a model-based framework, equally reconciled experimental results. In total, our work illustrates how conventional assumptions about the relationships between autonomic activity and frequency-domain HRV metrics break down, even in a simple model. This underscores the need for further experimental work towards unraveling the underlying mechanisms of autonomic dysfunction and HRV changes in systemic inflammation. Understanding the extent of information encoded in HRV signals is critical in appropriately analyzing prior and future studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Impact of Narrative Expressive Writing on Heart Rate, Heart Rate Variability, and Blood Pressure After Marital Separation.

    Science.gov (United States)

    Bourassa, Kyle J; Allen, John J B; Mehl, Matthias R; Sbarra, David A

    Divorce is a common stressor that is associated with increased risk for poor long-term physical and mental health. Using an experimental design, the current study examined the impact of expressive writing (EW) on average heart rate (HR), HR variability (HRV), and blood pressure (BP) 7.5 months later. Participants from a community sample of recently separated adults (N = 109) were assigned to one of three conditions: traditional EW, narrative EW, or a control writing condition, and were assessed three times for an average of 7.5 months. Each study visit included 27 minutes of physiological assessment; the primary outcomes at each assessment were mean-level HR, HRV, BP scores averaged across six different tasks. Participants in the traditional EW condition did not significantly differ from control participants in their later HR, HRV, or BP. However, relative to control participants, those in the narrative EW condition had significantly lower HR (B = -3.41, 95% confidence interval = -5.76 to -1.06, p = .004) and higher HRV 7.5 months later (B = 0.41, 95% confidence interval = 0.16 to 0.74, p = .001). When comparing narrative EW participants to those in the traditional EW and control writing as a single group, these effects remained and were moderately sized, Cohen d values of -0.61 and 0.60, respectively, and durable across all task conditions when analyzed in independent models. The writing condition groups did not differ in their later BP. Narrative EW decreased HR and increased HRV after marital separation but did not affect BP. We discuss the possible disconnect between psychology and physiology in response to EW, as well as possible future clinical applications after marital separation.

  3. A healthy heart is not a metronome: An integrative review of the heart’s anatomy and heart rate variability

    Directory of Open Access Journals (Sweden)

    Fredric Bruce Shaffer

    2014-09-01

    Full Text Available Heart rate variability (HRV, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF, very-low-frequency (VLF, low-frequency (LF, and high-frequency (HF bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges’ polyvagal theory, Thayer and colleagues’ neurovisceral integration model, Lehrer, Vaschillo, and Vaschillo’s resonance frequency model, and the Institute of HeartMath’s coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  4. Effect of Dietary Omega-3 Polyunsaturated Fatty Acids on Heart Rate and Heart Rate Variability in Animals Susceptible or Resistant to Ventricular Fibrillation

    Directory of Open Access Journals (Sweden)

    George E Billman

    2012-03-01

    Full Text Available The consumption of omega-3 polyunsaturated fatty acids (n-3 PUFAs has been reported to reduce cardiac mortality following myocardial infarction as well as to decrease resting heart rate (HR and increase heart rate variability (HRV. However, it has not been established whether n-3 PUFAs exhibit the same actions on HR and HRV in individuals known to be either susceptible or resistant to ventricular fibrillation (VF. Therefore, HR and HRV (high frequency and total R-R interval variability were evaluated before and 3 months after n-3 PUFA treatment in dogs with healed myocardial infarction that were either susceptible (VF+, n = 31 or resistant (VF-, n = 31 to ventricular tachyarrhythmias induced by a 2 min coronary artery occlusion during the last minute of a submaximal exercise test. HR and HRV were evaluated at rest, during submaximal exercise and in response to acute myocardial ischemia at rest before and after either placebo (1 g/day, corn oil, VF+, n = 9; VF- n = 8 or n-3 PUFA (docosahexaenoic acid + eicosapentaenoic acid ethyl esters, 1-4g/day, VF+, n = 22; VF-, n = 23 treatment for 3 months. The n-3 PUFA treatment elicited similar increases in red blood cell membrane, right atrial, and left ventricular n-3 PUFA levels in both the VF+ and VF- dogs. The n-3 PUFA treatment also provoked similar reductions in baseline HR and increases in baseline HRV in both groups that resulted in parallel shifts in the response to either exercise or acute myocardial ischemia (that is, the change in these variables induced by physiological challenges was not altered after n-3 PUFA treatment. These data demonstrate that dietary n-3 PUFA decreased HR and increased HRV to a similar extent in animals known to be prone to or resistant to malignant cardiac tachyarrhythmias.

  5. Serum total bilirubin levels and coronary heart disease--Causal association or epiphenomenon?

    Science.gov (United States)

    Kunutsor, Setor K

    2015-12-01

    Observational epidemiological evidence supports a linear inverse and independent association between serum total bilirubin levels and coronary heart disease (CHD) risk, but whether this association is causal remains to be ascertained. A Mendelian randomization approach was employed to test whether serum total bilirubin is causally linked to CHD. The genetic variant rs6742078--well known to specifically modify levels of serum total bilirubin and accounting for up to 20% of the variance in circulating serum total bilirubin levels--was used as an instrumental variable. In pooled analysis of estimates reported from published genome-wide association studies, every copy of the T allele of rs6742078 was associated with 0.42 standard deviation (SD) higher levels of serum total bilirubin (95% confidence interval, 0.40 to 0.43). Based on combined data from the Coronary Artery Disease Genome wide Replication and Meta-analyses and the Coronary Artery Disease (C4D) Genetics Consortium involving a total of 36,763 CHD cases and 76,997 controls, the odds ratio for CHD per copy of the T allele was 1.01 (95% confidence interval, 0.99 to 1.04). The odds ratio of CHD for a 1 SD genetically elevated serum total bilirubin level was 1.03 (95% confidence interval, 0.98 to 1.09). The current findings casts doubt on a strong causal association of serum total bilirubin levels with CHD. The inverse associations demonstrated in observational studies may be driven by biases such as unmeasured confounding and/or reverse causation. However, further research in large-scale consortia is needed. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Ambulatory ECG and analysis of heart rate variability in Parkinson's disease.

    Science.gov (United States)

    Haapaniemi, T H; Pursiainen, V; Korpelainen, J T; Huikuri, H V; Sotaniemi, K A; Myllylä, V V

    2001-03-01

    Cardiovascular reflex tests have shown both sympathetic and parasympathetic failure in Parkinson's disease. These tests, however, describe the autonomic responses during a restricted time period and have great individual variability, providing a limited view of the autonomic cardiac control mechanisms. Thus, they do not reflect tonic autonomic regulation. The aim was to examine tonic autonomic cardiovascular regulation in untreated patients with Parkinson's disease. 24 Hour ambulatory ECG was recorded in 54 untreated patients with Parkinson's disease and 47 age matched healthy subjects. In addition to the traditional spectral (very low frequency, VLF; low frequency, LF; high frequency, HF) and non-spectral components of heart rate variability, instantaneous beat to beat variability (SD1) and long term continuous variability (SD2) derived from Poincaré plots, and the slope of the power law relation were analysed. All spectral components (plaw relation (pParkinson's disease than in the control subjects. The Unified Parkinson's disease rating scale total and motor scores had a negative correlation with VLF and LF power spectrum values and the power law relation slopes. Patients with mild hypokinesia had higher HF values than patients with more severe hypokinesia. Tremor and rigidity were not associated with the HR variability parameters. Parkinson's disease causes dysfunction of the diurnal autonomic cardiovascular regulation as demonstrated by the spectral measures of heart rate variability and the slope of the power law relation. This dysfunction seems to be more profound in patients with more severe Parkinson's disease.

  7. Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time

    International Nuclear Information System (INIS)

    Zhang, Shi-Zheng; Hu, Xiu-Hua; Zhang, Qiao-Wei; Huang, Wen-Xin

    2005-01-01

    The aim of our study is to evaluate computed tomography (CT) coronary angiography in patients with a high heart rate using 16-slice spiral CT with 0.37-s gantry rotation time. We compare the image quality of patients whose heart rates were over 70 beats per minute (bpm) with that of patients whose heart rates were 70 bpm or less. Sixty patients with various heart rates underwent retrospectively ECG-gated multislice spiral CT (MSCT) coronary angiography. Two experienced observers who were blind to the heart rates of the patients evaluated all the MSCT coronary angiographic images and calculated the assessable segments. A total of 620 out of 891 (69.6%) segments were satisfactorily visualized. On average, 10.3 coronary artery segments per patient could be evaluated. In 36 patients whose heart rates were below 70 bpm [mean 62.2 bpm±5.32 (standard deviation, SD)], the number of assessable segments was 10.72±2.02 (SD). In the other 24 patients whose heart rates were above 70 bpm [mean 78.6 bpm±8.24 (SD)], the corresponding number was 9.75±1.74 (SD). No statistically significant difference was found in these two subgroups' t test, P>0.05. The new generation of 16-slice spiral CT with 0.37-s rotation time can satisfactorily evaluate the coronary arteries of patients with high heart rates (above 70 bpm, up to 102 bpm). (orig.)

  8. Heart rate variability in the standing position reflects training adaptation in professional soccer players.

    Science.gov (United States)

    Ravé, Guillaume; Fortrat, Jacques-Olivier

    2016-08-01

    To show that heart rate variability (HRV) in the standing position better reflects the way in which athletes adapt to training in so-called intermittent sports than the indicator of resting parasympathetic tone usually employed in endurance sports. Twenty professional soccer players (intermittent sport) took part in a 5-week training session divided into three successive periods: "Warm-up", "Intensive training" and "Tapering". At the beginning and end of each of the three periods, a stand test was carried out and the heart rate was recorded, beat by beat (Polar Team 2). We analysed HRV to determine the indicator mostly used to demonstrate training adaptation in endurance sports (lnRMSSD supine, natural logarithm of root mean square of the successive differences) as well as indicators obtained by means of spectral analysis in both supine and standing position. A decrease in heart rate was observed in the supine position at rest during training (-5.2 ± 1.3 bpm) while lnRMSSD and spectral analysis indicators remained unchanged. The "Warm-up" caused an increase in spectral analysis total power in standing position which was further highlighted by "Tapering" (3.39 ± 0.09, 3.61 ± 0.08 and 3.65 ± 0.09 log ms(2), respectively). However, the autonomic changes are probably more complex than a change in autonomic activity or balance since spectral analysis autonomic indicators remained unchanged. HRV in the standing position could monitor training adaptation in intermittent sports contrary to the indicator usually employed in endurance sports. However, the significance of the HRV change in the standing position during training remains unclear.

  9. Visualization of heart rate variability of long-term heart transplant patient by transition networks: a case report

    Directory of Open Access Journals (Sweden)

    Joanna eWdowczyk

    2016-03-01

    Full Text Available We present a heart transplant patient at his 17th year of uncomplicated follow-up. Within a frame of routine check out several tests were performed. With such a long and uneventful follow-up some degree of graft reinnervation could be anticipated. However, the patient's electrocardiogram and exercise parameters seemed largely inconclusive in this regard. The exercise heart rate dynamics were suggestive of only mild, if any parasympathetic reinnervation of the graft with persisting sympathetic activation. On the other hand, traditional heart rate variability (HRV indices were inadequately high, due to erratic rhythm resulting from interference of the persisting recipient sinus node or nonconducted atrial parasystole. New tools, originated from network representation of time series, by visualization short-term dynamical patterns, provided a method to discern HRV increase due to reinnervation from other reasons.

  10. Numerical modeling of dynamics of heart rate and arterial pressure during passive orthostatic test

    Science.gov (United States)

    Ishbulatov, Yu. M.; Kiselev, A. R.; Karavaev, A. S.

    2018-04-01

    A model of human cardiovascular system is proposed to describe the main heart rhythm, influence of autonomous regulation on frequency and strength of heart contractions and resistance of arterial vessels; process of formation of arterial pressure during systolic and diastolic phases; influence of respiration; synchronization between loops of autonomous regulation. The proposed model is used to simulate the dynamics of heart rate and arterial pressure during passive transition from supine to upright position. Results of mathematical modeling are compared to original experimental data.

  11. Visibility graph analysis of heart rate time series and bio-marker of congestive heart failure

    Science.gov (United States)

    Bhaduri, Anirban; Bhaduri, Susmita; Ghosh, Dipak

    2017-09-01

    Study of RR interval time series for Congestive Heart Failure had been an area of study with different methods including non-linear methods. In this article the cardiac dynamics of heart beat are explored in the light of complex network analysis, viz. visibility graph method. Heart beat (RR Interval) time series data taken from Physionet database [46, 47] belonging to two groups of subjects, diseased (congestive heart failure) (29 in number) and normal (54 in number) are analyzed with the technique. The overall results show that a quantitative parameter can significantly differentiate between the diseased subjects and the normal subjects as well as different stages of the disease. Further, the data when split into periods of around 1 hour each and analyzed separately, also shows the same consistent differences. This quantitative parameter obtained using the visibility graph analysis thereby can be used as a potential bio-marker as well as a subsequent alarm generation mechanism for predicting the onset of Congestive Heart Failure.

  12. 38 CFR 4.15 - Total disability ratings.

    Science.gov (United States)

    2010-07-01

    ... must be given to unusual physical or mental effects in individual cases, to peculiar effects of occupational activities, to defects in physical or mental endowment preventing the usual amount of success in overcoming the handicap of disability and to the effect of combinations of disability. Total disability will...

  13. Paradoxical dissociation between heart rate and heart rate variability following different modalities of exercise in individuals with metabolic syndrome: The RESOLVE study.

    Science.gov (United States)

    Boudet, Gil; Walther, Guillaume; Courteix, Daniel; Obert, Philippe; Lesourd, Bruno; Pereira, Bruno; Chapier, Robert; Vinet, Agnès; Chamoux, Alain; Naughton, Geraldine; Poirier, Paul; Dutheil, Frédéric

    2017-02-01

    Aims To analyse the effects of different modalities of exercise training on heart rate variability (HRV) in individuals with metabolic syndrome (MetS). Methods and results Eighty MetS participants (aged 50-70 years) were housed and managed in an inpatient medical centre for 21 days, including weekends. Physical activity and food intake/diet were intensively monitored. Participants were randomly assigned into three training groups, differing only by intensity of exercise: moderate-endurance-moderate-resistance ( re), high-resistance-moderate-endurance ( Re), and moderate-resistance-high-endurance ( rE). HRV was recorded before and after the intervention by 24-hour Holter electrocardiogram. Although mean 24-hour heart rate decreased more in Re than re (-11.6 ± 1.6 vs. -4.8 ± 2.1%; P = 0.010), low frequency/high frequency decreased more in re than Re (-20.4 ± 5.5% vs. + 20.4 ± 9.1%; P = 0.002) and rE (-20.4 ± 5.5% vs. -0.3 ± 11.1%; P = 0.003). Very low frequency increased more in Re than re (+121.2 ± 35.7 vs. 42.9 ± 11.3%; P = 0.004). For all HRV parameters, rE ranged between re and Re values. Low frequency/high frequency changes were linked with visceral fat loss only in re (coefficient 5.9, 95% CI 1.9-10.0; P = 0.004). By day 21, HRV parameters of MetS groups (heart rate -8.6 ± 1.0%, standard deviation of R-R intervals + 34.0 ± 6.6%, total power + 63.3 ± 11.1%; P < 0.001) became closer to values of 50 aged-matched healthy controls. Conclusions A 3-week residential programme with intensive volumes of physical activity (15-20 hours per week) enhanced HRV in individuals with MetS. Participants with moderate intensity of training had greater improvements in sympathovagal balance, whereas those with high intensity in resistance training had greater decreases in heart rate and greater increases in very low frequency. Modality-specific relationships were observed between enhanced HRV

  14. Human Fitting Studies of Cleveland Clinic Continuous-Flow Total Artificial Heart

    Science.gov (United States)

    Karimov, Jamshid H.; Steffen, Robert J.; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Cruz, Vincent; Golding, Leonard A.R.; Fukamachi, Kiyotaka; Moazami, Nader

    2015-01-01

    Implantation of mechanical circulatory support devices is challenging, especially in patients with a small chest cavity. We evaluated how well the Cleveland Clinic continuous-flow total artificial heart (CFTAH) fit the anatomy of patients about to receive a heart transplant. A mock pump model of the CFTAH was rapid-prototyped using biocompatible materials. The model was brought to the operative table, and the direction, length, and angulation of the inflow/outflow ports and outflow conduits were evaluated after the recipient's ventricles had been resected. Thoracic cavity measurements were based on preoperative computed tomographic data. The CFTAH fit well in all five patients (height, 170 ± 9 cm; weight, 75 ± 24 kg). Body surface area was 1.9 ± 0.3 m2 (range, 1.6-2.1 m2). The required inflow and outflow port orientation of both the left and right housings appeared consistent with the current version of the CFTAH implanted in calves. The left outflow conduit remained straight, but the right outflow direction necessitated a 73 ± 22 degree angulation to prevent potential kinking when crossing over the connected left outflow. These data support the fact that our design achieves the proper anatomical relationship of the CFTAH to a patient's native vessels. PMID:25806613

  15. Investigation of the Durability of a Diaphragm for a Total Artificial Heart.

    Science.gov (United States)

    Gräf, Felix; Rossbroich, Ralf; Finocchiaro, Thomas; Steinseifer, Ulrich

    2016-10-01

    One of the most critical components regarding the durability of the ReinHeart total artificial heart (TAH) is its biocompatible diaphragm, which separates the drive unit from the ventricles. Hence, a durability tester was designed to investigate its required 5-year lifetime. The aim of this study was to prove the validity of accelerated testing of the polyurethane diaphragm. The durability tester allows simultaneous testing of 12 diaphragms and mimics physiological conditions. To accelerate the time of testing, it operates with an increased speed at a frequency of 8 Hz. To prove the correctness of this acceleration, a servo-hydraulic testing machine was used to study the effect of different frequencies and their corresponding loads. Thereby the viscoelastic behavior of the polyurethane was investigated. Additionally, high-speed video measurements were performed. The force against frequency and the high-speed video measurements showed constant behavior. In the range of 1-10 Hz, the maximum resulting forces varied by 3%, and the diaphragm movement was identical. Frequencies below 10 Hz allow a valid statement of the diaphragm's mechanical durability. Viscoelasticity of the polyurethane in the considered frequency-range is negligible. The accelerated durability test is applicable to polyurethane diaphragms, and the results are applicable to TAH use. The reliability of the diaphragm for a lifetime of 5 years was found to be 80% with a confidence of 62%. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  16. Estimation of Filling and Afterload Conditions by Pump Intrinsic Parameters in a Pulsatile Total Artificial Heart.

    Science.gov (United States)

    Cuenca-Navalon, Elena; Laumen, Marco; Finocchiaro, Thomas; Steinseifer, Ulrich

    2016-07-01

    A physiological control algorithm is being developed to ensure an optimal physiological interaction between the ReinHeart total artificial heart (TAH) and the circulatory system. A key factor for that is the long-term, accurate determination of the hemodynamic state of the cardiovascular system. This study presents a method to determine estimation models for predicting hemodynamic parameters (pump chamber filling and afterload) from both left and right cardiovascular circulations. The estimation models are based on linear regression models that correlate filling and afterload values with pump intrinsic parameters derived from measured values of motor current and piston position. Predictions for filling lie in average within 5% from actual values, predictions for systemic afterload (AoPmean , AoPsys ) and mean pulmonary afterload (PAPmean ) lie in average within 9% from actual values. Predictions for systolic pulmonary afterload (PAPsys ) present an average deviation of 14%. The estimation models show satisfactory prediction and confidence intervals and are thus suitable to estimate hemodynamic parameters. This method and derived estimation models are a valuable alternative to implanted sensors and are an essential step for the development of a physiological control algorithm for a fully implantable TAH. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  17. Design of heart rate monitor based on piezoelectric sensor using an Arduino

    Science.gov (United States)

    Setyowati, Veni; Muninggar, Jodelin; Shanti. N. A, Made R. S.

    2017-01-01

    Reading of result heart rate using an acoustic stethoscope needs a particular skill, quiet environment, and hearing sensitivity. This project had the purpose design of a user-friendly automatic heart rate monitor and especially in a noisy area which to eliminate problems and incorrect reading of result. The liquid crystal display shows a heart rate as a result of measurements. The design of the heart rate monitor has two main parts; the signal recorder that a piezoelectric sensor, a filter, and an amplifier as recorder. The second parts was Arduino microcontroller with reinforced. Besides, three supporting buttons provided as the manual switches, the ‘on’, the ‘start’, and ‘reset’ buttons. The values acquired from the heart rate monitor indicate that those were on the Vernier BPS-BTA value range. The measurement error factor of the heart rate monitor then compared to the Vernier BPS-BTA test device was 3.15%. Besides, the value of statistical independent-test indicates that there is no significant difference (P = 0.971) between the heart rate monitor device and the Vernier BPS-BTA. In conclusion, this device was ready to be used because it has almost the same accuracy with the standart device.

  18. Relationships between heart rate and age, bodyweight and breed in 10,849 dogs.

    Science.gov (United States)

    Hezzell, M J; Dennis, S G; Humm, K; Agee, L; Boswood, A

    2013-06-01

    To evaluate relationships between heart rate and clinical variables in healthy dogs and dogs examined at a referral hospital. Clinical data were extracted from the electronic patient records of a first opinion group (5000 healthy dogs) and a referral hospital (5849 dogs). Univariable and multi-variable general linear models were used to assess associations between heart rate and clinical characteristics. Separate multi-variable models were constructed for first opinion and referral populations. In healthy dogs, heart rate was negatively associated with bodyweight (PChihuahuas. The mean difference in heart rate between a 5 and 55 kg dog was 10.5 beats per minute. In dogs presenting to a referral hospital, heart rate was negatively associated with bodyweight (P<0.001) and the following breeds; border collie, golden retriever, Labrador retriever, springer spaniel and West Highland white terrier and positively associated with age, admitting service (emergency and critical care, emergency first opinion and cardiology) and the following breeds; Cavalier King Charles spaniel, Staffordshire bull terrier and Yorkshire terrier. Bodyweight, age, breed and disease status all influence heart rate in dogs, although these factors account for a relatively small proportion of the overall variability in heart rate. © 2013 British Small Animal Veterinary Association.

  19. Change of Diurnal Heart Rate Patterns During Pregnancy and Lactation in Dogs (Canis familiaris

    Directory of Open Access Journals (Sweden)

    Häggström J

    2003-09-01

    Full Text Available Pregnancy and lactation involve great demands on the cardiovascular system. The purpose of this study was to investigate how the heart rate and diurnal heart rate pattern change when dogs become pregnant or lactate. Five clinically healthy female beagle dogs were mated, and delivered three to seven healthy puppies. The heart rate was investigated with 24-h ECG (Holter once during anoestrus, at 3, 5, 7 and 9 weeks of pregnancy, and at week 4 postpartum (lactation. However, at 9 weeks, the ECG could not be recorded for the fully 24 h in 4 of 5 dogs, because labour started and the dogs then appeared disturbed by the recordings. The results at this date are not included in the statistical comparison. The heart rate increased progressively during pregnancy and was still elevated at 4 weeks of lactation. During late pregnancy the difference in heart rates between daytime and nighttime became smaller, but the heart rate was significantly higher in daytime in all periods. In conclusion, the increased heart rates during pregnancy and lactation reflect increased demands on the cardiovascular system and may be important to consider in clinical practice.

  20. Variation in heart rate influences the assessment of transient ischemic dilation in myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Leslie, William D; Levin, Daniel P; Demeter, Sandor J

    2007-01-01

    Transient arrhythmias can affect transient ischemic dilation (TID) ratios. This study was initiated to evaluate the frequency and effect of normal heart rate change on TID measures in routine clinical practice. Consecutive patients undergoing stress/rest sestamibi gated myocardial perfusion scintigraphy were studied (N = 407). Heart rate at the time of stress and rest imaging were recorded. TID ratios were analyzed in relation to absolute change in heart rate (stress minus rest) for subjects with normal perfusion and systolic function (Group 1, N = 169) and those with abnormalities in perfusion and/or function (Group 2, N = 238). In Group 1, mean TID ratio was inversely correlated with the change in heart rate (r = -0.47, P < 0.0001). For every increase of 10 BPM in heart rate change, the TID ratio decreased by approximately 0.06 (95% confidence interval 0.04–0.07). In Group 2, multiple linear regression demonstrated that the change in heart rate (beta = -0.25, P < 0.0001) and the summed difference score (beta = 0.36, P < 0.0001) were independent predictors of the TID ratio. Normal variation in heart rate between the stress and rest components of myocardial perfusion scans is common and can influence TID ratios in patients with normal and abnormal cardiac scans

  1. Validity of a heart rate monitor during work in the laboratory and on the Space Shuttle

    Science.gov (United States)

    Moore, A. D. Jr; Lee, S. M.; Greenisen, M. C.; Bishop, P.

    1997-01-01

    Accurate heart rate measurement during work is required for many industrial hygiene and ergonomics situations. The purpose of this investigation was to determine the validity of heart rate measurements obtained by a simple, lightweight, commercially available wrist-worn heart rate monitor (HRM) during work (cycle exercise) sessions conducted in the laboratory and also during the particularly challenging work environment of space flight. Three different comparisons were made. The first compared HRM data to simultaneous electrocardiogram (ECG) recordings of varying heart rates that were generated by an ECG simulator. The second compared HRM data to ECG recordings collected during work sessions of 14 subjects in the laboratory. Finally, ECG downlink and HRM data were compared in four astronauts who performed cycle exercise during space flight. The data were analyzed using regression techniques. The results were that the HRM recorded virtually identical heart rates compared with ECG recordings for the data set generated by an ECG simulator. The regression equation for the relationship between ECG versus HRM heart rate data during work in the laboratory was: ECG HR = 0.99 x (HRM) + 0.82 (r2 = 0.99). Finally, the agreement between ECG downlink data and HRM data during space flight was also very high, with the regression equation being: Downlink ECG HR = 1.05 x (HRM) -5.71 (r2 = 0.99). The results of this study indicate that the HRM provides accurate data and may be used to reliably obtain valid data regarding heart rate responses during work.

  2. Effect of aerobic training on heart rate recovery in patients with established heart disease; a systematic review

    NARCIS (Netherlands)

    Snoek, Johan A.; Van Berkel, Sietske; Van Meeteren, Nico; Backx, Frank J G; Daanen, Hein A M

    2013-01-01

    Background: Although a delayed decrease in heart rate during the first minute after graded exercise has been identified as a powerful predictor of overall mortality in cardiac patients, the potential to influence this risk factor by aerobic training remains to be proven. Objective: The aim was to

  3. Heart Rate and Energy Expenditure in Division I Field Hockey Players During Competitive Play.

    Science.gov (United States)

    Sell, Katie M; Ledesma, Allison B

    2016-08-01

    Sell, KM and Ledesma, AB. Heart rate and energy expenditure in Division I field hockey players during competitive play. J Strength Cond Res 30(8): 2122-2128, 2016-The purpose of this study was to quantify energy expenditure and heart rate data for Division I female field hockey players during competitive play. Ten female Division I collegiate field hockey athletes (19.8 ± 1.6 years; 166.4 ± 6.1 cm; 58.2 ± 5.3 kg) completed the Yo-Yo intermittent endurance test to determine maximal heart rate. One week later, all subjects wore a heart rate monitor during a series of 3 matches in an off-season competition. Average heart rate (AvHR), average percentage of maximal heart rate (AvHR%), peak exercise heart rate (PExHR), and percentage of maximal heart rate (PExHR%), time spent in each of the predetermined heart rate zones, and caloric expenditure per minute of exercise (kcalM) were determined for all players. Differences between positions (backs, midfielders, and forwards) were assessed. No significant differences in AvHR, AvHR%, PExHR, PExHR%, and %TM were observed between playing positions. The AvHR% and PExHR% for each position fell into zones 4 (77-93% HRmax) and 5 (>93% HRmax), respectively, and significantly more time was spent in zone 4 compared with zones 1, 2, 3, and 5 across all players (p ≤ 0.05). The kcalM reflected very heavy intensity exercise. The results of this study will contribute toward understanding the sport-specific physiological demands of women's field hockey and has specific implications for the duration and schedule of training regimens.

  4. Reduced heart rate variability in social anxiety disorder: associations with gender and symptom severity.

    Directory of Open Access Journals (Sweden)

    Gail A Alvares

    Full Text Available BACKGROUND: Polyvagal theory emphasizes that autonomic nervous system functioning plays a key role in social behavior and emotion. The theory predicts that psychiatric disorders of social dysfunction are associated with reduced heart rate variability, an index of autonomic control, as well as social inhibition and avoidance. The purpose of this study was to examine whether heart rate variability was reduced in treatment-seeking patients diagnosed with social anxiety disorder, a disorder characterized by social fear and avoidance. METHODS: Social anxiety patients (n = 53 were recruited prior to receiving psychological therapy. Healthy volunteers were recruited through the University of Sydney and the general community and were matched by gender and age (n = 53. Heart rate variability was assessed during a five-minute recording at rest, with participants completing a range of self-report clinical symptom measures. RESULTS: Compared to controls, participants with social anxiety exhibited significant reductions across a number of heart rate variability measures. Reductions in heart rate variability were observed in females with social anxiety, compared to female controls, and in patients taking psychotropic medication compared to non-medicated patients. Finally, within the clinical group, we observed significant associations between reduced heart rate variability and increased social interaction anxiety, psychological distress, and harmful alcohol use. CONCLUSIONS: The results of this study confirm that social anxiety disorder is associated with reduced heart rate variability. Resting state heart rate variability may therefore be considered a marker for social approach-related motivation and capacity for social engagement. Additionally, heart rate variability may provide a useful biomarker to explain underlying difficulties with social approach, impaired stress regulation, and behavioral inhibition, especially in disorders associated with

  5. Real-time Continuous Assessment Method for Mental and Physiological Condition using Heart Rate Variability

    Science.gov (United States)

    Yoshida, Yutaka; Yokoyama, Kiyoko; Ishii, Naohiro

    It is necessary to monitor the daily health condition for preventing stress syndrome. In this study, it was proposed the method assessing the mental and physiological condition, such as the work stress or the relaxation, using heart rate variability at real time and continuously. The instantanuous heart rate (HR), and the ratio of the number of extreme points (NEP) and the number of heart beats were calculated for assessing mental and physiological condition. In this method, 20 beats heart rate were used to calculate these indexes. These were calculated in one beat interval. Three conditions, which are sitting rest, performing mental arithmetic and watching relaxation movie, were assessed using our proposed algorithm. The assessment accuracies were 71.9% and 55.8%, when performing mental arithmetic and watching relaxation movie respectively. In this method, the mental and physiological condition was assessed using only 20 regressive heart beats, so this method is considered as the real time assessment method.

  6. Development of a microcontroller-based automatic control system for the electrohydraulic total artificial heart.

    Science.gov (United States)

    Kim, H C; Khanwilkar, P S; Bearnson, G B; Olsen, D B

    1997-01-01

    An automatic physiological control system for the actively filled, alternately pumped ventricles of the volumetrically coupled, electrohydraulic total artificial heart (EHTAH) was developed for long-term use. The automatic control system must ensure that the device: 1) maintains a physiological response of cardiac output, 2) compensates for an nonphysiological condition, and 3) is stable, reliable, and operates at a high power efficiency. The developed automatic control system met these requirements both in vitro, in week-long continuous mock circulation tests, and in vivo, in acute open-chested animals (calves). Satisfactory results were also obtained in a series of chronic animal experiments, including 21 days of continuous operation of the fully automatic control mode, and 138 days of operation in a manual mode, in a 159-day calf implant.

  7. Histopathology Image Analysis in Two Long-Term Animal Experiments with Helical Flow Total Artificial Heart.

    Science.gov (United States)

    Wotke, Jiri; Homolka, Pavel; Vasku, Jaromír; Dobsak, Petr; Palanova, Petra; Mrkvicova, Veronika; Konecny, Petr; Soska, Vladimir; Pohanka, Michal; Novakova, Marie; Yurimoto, Terumi; Saito, Itsuro; Inoue, Yusuke; Isoyama, Takashi; Abe, Yusuke

    2016-12-01

    Histopathological analysis can provide important information in long-term experiments with total artificial heart (TAH). Recently, a new type of blood pump, the helical flow total artificial heart (HF-TAH) was developed. This study aimed to investigate the changes in selected vital organs in animal experiments with implanted HF-TAH. Samples from lung, liver, and kidneys from two female goats (No. 1301 and No. 1304) with implanted HF-TAH were analyzed. Tissue samples were fixed in 10% formaldehyde and 4 µm thick transverse sections were stained with hematoxylin-eosin (HE). Additional staining was done for detection of connective tissue (Masson-Goldner stain) and for detection of iron (hemosiderin) deposits (Perls stain). Sections were scanned at 100× and 500× magnification with a light microscope. Experiment no. 1301 survived 100 days (cause of termination was heavy damage of the right pump); experimental goat no.1304 survived 68 days and was sacrificed due to severe right hydrodynamic bearing malfunction. Histopathological analysis of liver samples proved signs of chronic venostasis with limited focal necrotic zones. Dilated tubules, proteinaceous material in tubular lumen, and hemosiderin deposits were detected in kidney samples. Contamination of the organs by embolized micro-particles was suspected at the autopsy after discovery of visible damage (scratches) of the pump impeller surface (made from titanium alloy) in both experiments. Sporadic deposits of foreign micro-particles (presumably titanium) were observed in most of the analyzed parenchymal organs. However, the described deposits were not in direct connection with inflammatory reactions in the analyzed tissues. Histopathological analysis showed the presence of minimal contamination of the lung, kidney, and liver tissue samples by foreign material (titanium very likely). The analysis showed only limited pathological changes, especially in liver and kidneys, which might be attributed to the influence of

  8. Effects of spinal manipulation and myofascial techniques on heart rate variability: A systematic review.

    Science.gov (United States)

    Amoroso Borges, Bruno Luis; Bortolazzo, Gustavo Luiz; Neto, Hugo Pasin

    2018-01-01

    The analysis of heart rate variability is important to the investigation of stimuli from the autonomic nervous system. Osteopathy is a form of treatment that can influence this system in healthy individuals as well as those with a disorder or disease. The aim of the present study was to perform a systematic review of the literature regarding the effect of spinal manipulation and myofascial techniques on heart rate variability. Searches were performed of the Pubmed, Scielo, Lilacs, PEDro, Ibesco, Cochrane and Scopus databases for relevant studies. The PEDro scale was used to assess the methodological quality of each study selected. A total of 505 articles were retrieved during the initial search. After an analysis of the abstracts, nine studies were selected for the present review. Based on the findings, osteopathy exerts an influence on the autonomic nervous system depending on the stimulation site and type. A greater parasympathetic response was found when stimulation was performed in the cervical and lumbar regions, whereas a greater sympathetic response was found when stimulation was performed in the thoracic region. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Using heart rate to prescribe physical exercise during head-out water immersion.

    Science.gov (United States)

    Kruel, Luiz F M; Peyré-Tartaruga, Leonardo A; Coertjens, Marcelo; Dias, Adriana B C; Da Silva, Rafael C; Rangel, Antônio C B

    2014-01-01

    The purpose of this study was to compare and correlate the effect of age group, sex, depth of water immersion, and the heart rate (HR) assessed out of the water on the HR behavior in individuals subjected to head-out water immersion. A total of 395 healthy individuals of both sexes, aged between 07 and 75 years, underwent vertical head-out water immersion. Heart rate was assessed out of the water in the supine and orthostatic (OHR) positions and at immersion depths corresponding to the ankle, knee, hip, umbilicus, xiphoid process, acromion, neck, and also the neck with the arms out of the water. The formula (ΔHR = OHR - HR immersion depth) was used to calculate the reduction in HR at each immersion depth. No age-based or sex-based differences in HR were found. The greater the depth of the water, the greater was the decrease in HR (p water-based exercise intensity performed during vertical immersion: OHR should be measured before the individual entering the aquatic environment; ΔHR should be measured according to the depth at which exercise is to be performed, and we suggest an adaptation to Karvonen's HRmax prediction formula (predicted HRmax: 220 - age - ΔHR) to prescribe and control the intensity of the exercise performed during vertical immersion.

  10. Changes in heart rate variability during anaesthesia induction using sevoflurane or isoflurane with nitrous oxide.

    Science.gov (United States)

    Nishiyama, Tomoki

    2016-01-01

    The purpose of this study was to compare cardiac sympathetic and parasympathetic balance using heart rate variability (HRV) during induction of anaesthesia between sevoflurane and isoflurane in combination with nitrous oxide. 40 individuals aged from 30 to 60 years, scheduled for general anaesthesia were equally divided into sevoflurane or isoflurane groups. After 100% oxygen inhalation for a few minutes, anaesthesia was induced with nitrous oxide 3 L min-1, oxygen 3 L min-1 and sevoflurane or isoflurane. Sevoflurane or isoflurane concentration was increased by 0.5% every 2 to 3 breaths until 5% was attained for sevoflurane, or 3% for isoflurane. Vecuronium was administered to facilitate tracheal intubation. After intubation, sevoflurane was set to 2% while isoflurane was set to 1% with nitrous oxide with oxygen (1:1) for 5 min. Both sevoflurane and isoflurane provoked a decrease in blood pressure, total power, the low frequency component (LF), and high frequency component (HF) of HRV. Although the heart rate increased during isoflurane anaesthesia, it decreased under sevoflurane. The power of LF and HF also decreased in both groups. LF was higher in the isoflurane group while HF was higher in the sevoflurane group. The LF/HF ratio increased transiently in the isoflurane group, but decreased in the sevoflurane group. Anaesthesia induction with isoflurane-nitrous oxide transiently increased cardiac sympathetic activity, while sevoflurane-nitrous oxide decreased both cardiac sympathetic and parasympathetic activities. The balance of cardiac parasympathetic/sympathetic activity was higher in sevoflurane anaesthesia.

  11. Pre-performance Physiological State: Heart Rate Variability as a Predictor of Shooting Performance.

    Science.gov (United States)

    Ortega, E; Wang, C J K

    2018-03-01

    Heart rate variability (HRV) is commonly used in sport science for monitoring the physiology of athletes but not as an indicator of physiological state from a psychological perspective. Since HRV is established to be an indicator of emotional responding, it could be an objective means of quantifying an athlete's subjective physiological state before competition. A total of 61 sport shooters participated in this study, of which 21 were novice shooters, 19 were intermediate shooters, and 21 were advanced level shooters. HRV, self-efficacy, and use of mental skills were assessed before they completed a standard shooting performance task of 40 shots, as in a competition qualifying round. The results showed that HRV was significantly positively correlated with self-efficacy and performance and was a significant predictor of shooting performance. In addition, advanced shooters were found to have significantly lower average heart rate before shooting and used more self-talk, relaxation, imagery, and automaticity compared to novice and intermediate shooters. HRV was found to be useful in identifying the physiological state of an athlete before competing, and as such, coaches and athletes can adopt practical strategies to improve the pre-performance physiological state as a means to optimize performance.

  12. Junior doctors in their first year: mental health, quality of life, burnout and heart rate variability.

    Science.gov (United States)

    Henning, Marcus A; Sollers, John; Strom, Joanna M; Hill, Andrew G; Lyndon, Mataroria P; Cumin, David; Hawken, Susan J

    2014-04-01

    There is a burgeoning interest in, and evidence of, quality of life and burnout issues among doctors. It was hypothesized that the junior doctors in this study would experience psychosocial and physiological changes over time, and that the obtained measures would indicate psychosocial and physiological anomalies. In addition, it was hypothesized that their psychosocial perceptions would be significantly associated with their physiological measures. A total sample of 17 junior doctors in their first year of training volunteered for this study. Over four time periods separated by 6 week phases, the doctors completed a set of quality of life and psychosocial inventories and wore a Polar RS800 Heart Rate Monitor over a day and night time interval. The findings showed that this sample of doctors did not report any problems associated with depression, anxiety, stress, burnout or quality of life (psychosocial measures). In addition, their heart rate variability scores (physiological measures) did not show any significant fluctuations. Furthermore, the responses from the self-report instruments measuring stress, anxiety, depression, quality of life and burnout did not consistently correlate with the HRV information suggesting a mind-body disconnection. More work needs to be done on larger samples to investigate these findings further given that the literature shows that junior doctors are likely to be stressed and working in stress-provoking environments.

  13. Effect of music tempo on exercise performance and heart rate among young adults.

    Science.gov (United States)

    Thakare, Avinash E; Mehrotra, Ranjeeta; Singh, Ayushi

    2017-01-01

    Music captures attention, triggers a range of emotions, alters or regulates mood, increases work output, heightens arousal, induces states of higher functioning, reduces inhibitions and encourages rhythmic movement. Music has ergo-genic effect as well, it increases exercise performance, delays fatigue and increases performance and endurance, power and strength. Our study tried to evaluate the effect of music on exercise performance in young untrained subjects. In this study, we tested the effect of music on sub maximal exercise performance time duration in young adults. 25 Male and 25 females were subjected to standard submaximal exercise with and without music. Resting HR and Max. HR during exercise and the exercise time duration was recorded. Total exercise duration in whole group with music (37.12 ± 16.26** min) was significantly greater than exercise duration without music (22.48 ± 10.26 min). Males (42.4 ± 15.6** min) outperformed significantly better than females (31.84 ± 15.48 min). Also, we observed statistically significant higher values of Maximal heart rate with music than without music. But there was no significant correlation between duration of exercise, music and change in Heart rate. We can conclude that Music increases duration of exercise in both sexes and hence endurance.

  14. Computerized analysis of fetal heart rate variability signal during the stages of labor.

    Science.gov (United States)

    Annunziata, Maria Laura; Tagliaferri, Salvatore; Esposito, Francesca Giovanna; Giuliano, Natascia; Mereghini, Flavia; Di Lieto, Andrea; Campanile, Marta

    2016-03-01

    To analyze computerized cardiotocographic (cCTG) parameters (baseline fetal heart rate, baseline FHR; short term variability, STV; approximate entropy, ApEn; low frequency, LF; movement frequency, MF; high frequency, HF) in physiological pregnancy in order to correlate them with the stages of labor. This could provide more information for understanding the mechanisms of nervous system control of FHR during labor progression. A total of 534 pregnant women were monitored on cCTG from the 37th week before the onset of spontaneous labor and during the first and the second stage of labor. Statistical analysis was performed using Kruskal-Wallis test and Wilcoxon rank-sum test with the Bonferroni adjusted α (labor, and the first and second stages of labor. Differences between some of the stages were found for ApEn, LF and for LF/(HF + MF), where the first and the third were reduced and the second was increased. cCTG modifications during labor may reflect the physiologic increased activation of the autonomous nervous system. Using computerized fetal heart rate analysis during labor it may be possible to obtain more information from the fetal cardiac signal, in comparison with the traditional tracing. © 2016 Japan Society of Obstetrics and Gynecology.

  15. Nonlinear analysis of heart rate variability in patients with eating disorders

    NARCIS (Netherlands)

    Vigo, Daniel E.; Castro, Mariana N.; Dorpinghaus, Andrea; Weidema, Hylke; Cardinali, Daniel P.; Siri, Leonardo Nicola; Rovira, Bernardo; Fahrer, Rodolfo D.; Nogues, Martin; Leiguarda, Ramon C.; Guinjoan, Salvador M.

    2008-01-01

    Patients with anorexia nervosa or bulimia nervosa often have signs of autonomic dysfunction potentially deleterious to the heart. The aim of this study was to ascertain the nonlinear properties of heart rate variability in patients with eating disorders. A group of 33 women with eating disorders (14

  16. Smart pillow for heart-rate monitoring using a fiber optic sensor

    Science.gov (United States)

    Chen, Zhihao; Teo, Ju Teng; Ng, Soon Huat; Yim, Huiqing

    2011-03-01

    In this paper, we propose and demonstrate a new method to monitor heart rate using fiber optic microbending based sensor for in-bed non-intrusive monitoring. The sensing system consists of transmitter, receiver, sensor mat, National Instrument (NI) data acquisition (DAQ) card and a computer for signal processing. The sensor mat is embedded inside a commercial pillow. The heart rate measurement system shows an accuracy of +/-2 beats, which has been successfully demonstrated in a field trial. The key technological advantage of our system is its ability to measure heart rate with no preparation and minimal compliance by the patient.

  17. GLP-1 receptor stimulation depresses heart rate variability and inhibits neurotransmission to cardiac vagal neurons.

    Science.gov (United States)

    Griffioen, Kathleen J; Wan, Ruiqian; Okun, Eitan; Wang, Xin; Lovett-Barr, Mary Rachael; Li, Yazhou; Mughal, Mohamed R; Mendelowitz, David; Mattson, Mark P

    2011-01-01

    glucagon-like peptide 1 (GLP-1) is an incretin hormone released from the gut in response to food intake. Whereas GLP-1 acts in the periphery to inhibit glucagon secretion and stimulate insulin release, it also acts in the central nervous system to mediate autonomic control of feeding, body temperature, and cardiovascular function. Because of its role as an incretin hormone, GLP-1 receptor analogs are used as a treatment for type 2 diabetes. Central or peripheral administration of GLP-1 increases blood pressure and heart rate, possibly by activating brainstem autonomic nuclei and increasing vagus nerve activity. However, the mechanism(s) by which GLP-1 receptor stimulation affects cardiovascular function are unknown. We used the long-lasting GLP-1 receptor agonist Exendin-4 (Ex-4) to test the hypothesis that GLP-1 signalling modulates central parasympathetic control of heart rate. using a telemetry system, we assessed heart rate in mice during central Ex-4 administration. Heart rate was increased by both acute and chronic central Ex-4 administration. Spectral analysis indicated that the high frequency and low frequency powers of heart rate variability were diminished by Ex-4 treatment. Finally, Ex-4 decreased both excitatory glutamatergic and inhibitory glycinergic neurotransmission to preganglionic parasympathetic cardiac vagal neurons. these data suggest that central GLP-1 receptor stimulation diminishes parasympathetic modulation of the heart thereby increasing heart rate.

  18. Spectral analysis of time series of events: effect of respiration on heart rate in neonates

    International Nuclear Information System (INIS)

    Van Drongelen, Wim; Williams, Amber L; Lasky, Robert E

    2009-01-01

    Certain types of biomedical processes such as the heart rate generator can be considered as signals that are sampled by the occurring events, i.e. QRS complexes. This sampling property generates problems for the evaluation of spectral parameters of such signals. First, the irregular occurrence of heart beats creates an unevenly sampled data set which must either be pre-processed (e.g. by using trace binning or interpolation) prior to spectral analysis, or analyzed with specialized methods (e.g. Lomb's algorithm). Second, the average occurrence of events determines the Nyquist limit for the sampled time series. Here we evaluate different types of spectral analysis of recordings of neonatal heart rate. Coupling between respiration and heart rate and the detection of heart rate itself are emphasized. We examine both standard and data adaptive frequency bands of heart rate signals generated by models of coupled oscillators and recorded data sets from neonates. We find that an important spectral artifact occurs due to a mirror effect around the Nyquist limit of half the average heart rate. Further we conclude that the presence of respiratory coupling can only be detected under low noise conditions and if a data-adaptive respiratory band is used

  19. Heart rate turbulence after ventricular premature beats in healthy Doberman pinschers and those with dilated cardiomyopathy.

    Science.gov (United States)

    Harris, J D; Little, C J L; Dennis, J M; Patteson, M W

    2017-10-01

    To describe the measurement of heart rate turbulence (HRT) after ventricular premature beats and compare HRT in healthy Doberman pinschers and those with dilated cardiomyopathy (DCM), with and without congestive heart failure (CHF). Sixty-five client-owned Dobermans: 20 healthy (NORMAL), 31 with preclinical DCM and 14 with DCM and CHF (DCM + CHF). A retrospective study of data retrieved from clinical records and ambulatory ECG (Holter) archives, including data collected previously for a large-scale prospective study of Dobermans with preclinical DCM. Holter data were reanalysed quantitatively, including conventional time-domain heart rate variability and the HRT parameters turbulence onset and turbulence slope. Heart rate turbulence could be measured in 58/65 dogs. Six Holter recordings had inadequate ventricular premature contractions (VPCs) and one exhibited VPCs too similar to sinus morphology. Heart rate turbulence parameter, turbulence onset, was significantly reduced in DCM dogs, whereas conventional heart rate variability measures were not. Heart rate variability and HRT markers were reduced in DCM + CHF dogs as expected. Heart rate turbulence can be measured from the majority of good quality standard canine 24-hour Holter recordings with >5 VPCs. Turbulence onset is significantly reduced in Dobermans with preclinical DCM which indicates vagal withdrawal early in the course of disease. Heart rate turbulence is a powerful prognostic indicator in human cardiac disease which can be measured from standard 24-hour ambulatory ECG (Holter) recordings using appropriate computer software. Further studies are warranted to assess whether HRT may be of prognostic value in dogs with preclinical DCM and in other canine cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Embryos in the fast lane: high-temperature heart rates of turtles decline after hatching.

    Directory of Open Access Journals (Sweden)

    Wei-Guo Du

    Full Text Available In ectotherms such as turtles, the relationship between cardiovascular function and temperature may be subject to different selective pressures in different life-history stages. Because embryos benefit by developing as rapidly as possible, and can "afford" to expend energy to do so (because they have access to the yolk for nutrition, they benefit from rapid heart (and thus, developmental rates. In contrast, hatchlings do not have a guaranteed food supply, and maximal growth rates may not enhance fitness--and so, we might expect a lower heart rate, especially at high temperatures where metabolic costs are greatest. Our data on two species of emydid turtles, Chrysemys picta, and Graptemys pseudogeographica kohnii, support these predictions. Heart rates of embryos and hatchlings were similar at low temperatures, but heart rates at higher temperatures were much greater before than after hatching.

  1. Physical Activity, Aerobic Capacity, and Total Antioxidant Capacity in Healthy Men and in Men with Coronary Heart Disease

    Directory of Open Access Journals (Sweden)

    Anna Gawron-Skarbek

    2015-01-01

    Full Text Available Objective. The purpose of the study was to assess total antioxidant capacity (TAC of blood serum in relation with habitual leisure time physical activity (LTPA and aerobic capacity in a group of 90 men with coronary heart disease (CHD aged 34.8–77.0 years and in 90 age-matched peers without CHD. Methods. Two spectrophotometric methods were applied to assess TAC: Ferric Reducing Ability of Serum (TAC-FRAS and 2.2-diphenyl-1-picryl-hydrazyl (TAC-DPPH tests. Aerobic capacity was expressed as physical working capacity at 85% of the maximal heart rate (PWC85%HRmax. Results. CHD patients had higher values of TACFRAS (1.37±0.28 versus 1.27±0.23 mmol FeCl2·L−1; P<0.05 but there were no group differences for TAC-DPPH and for uric acid (UA. Negative correlation was found between LTPA (also when calculated per kg of body mass and TAC-DPPH in CHD patients. In CHD patients, TAC-FRAS and UA were lower in subjects with higher aerobic capacity expressed as PWC85%HRmax/kg. Those associations were not found in healthy men. Conclusions. We conclude that TAC of blood serum is moderately adversely related to LTPA and aerobic capacity in patients with CHD. UA, as the main determinant of serum TAC, may be partially responsible for those associations.

  2. Physical Activity, Aerobic Capacity, and Total Antioxidant Capacity in Healthy Men and in Men with Coronary Heart Disease

    Science.gov (United States)

    Gawron-Skarbek, Anna; Kostka, Joanna; Nowak, Dariusz; Drygas, Wojciech; Jegier, Anna; Kostka, Tomasz

    2015-01-01

    Objective. The purpose of the study was to assess total antioxidant capacity (TAC) of blood serum in relation with habitual leisure time physical activity (LTPA) and aerobic capacity in a group of 90 men with coronary heart disease (CHD) aged 34.8–77.0 years and in 90 age-matched peers without CHD. Methods. Two spectrophotometric methods were applied to assess TAC: Ferric Reducing Ability of Serum (TAC-FRAS) and 2.2-diphenyl-1-picryl-hydrazyl (TAC-DPPH) tests. Aerobic capacity was expressed as physical working capacity at 85% of the maximal heart rate (PWC85%HRmax). Results. CHD patients had higher values of TACFRAS (1.37 ± 0.28 versus 1.27 ± 0.23 mmol FeCl2·L−1; P < 0.05) but there were no group differences for TAC-DPPH and for uric acid (UA). Negative correlation was found between LTPA (also when calculated per kg of body mass) and TAC-DPPH in CHD patients. In CHD patients, TAC-FRAS and UA were lower in subjects with higher aerobic capacity expressed as PWC85%HRmax/kg. Those associations were not found in healthy men. Conclusions. We conclude that TAC of blood serum is moderately adversely related to LTPA and aerobic capacity in patients with CHD. UA, as the main determinant of serum TAC, may be partially responsible for those associations. PMID:26451234

  3. Music close to one's heart: heart rate variability with music, diagnostic with e-bra and smartphone

    Science.gov (United States)

    Hegde, Shantala; Kumar, Prashanth S.; Rai, Pratyush; Mathur, Gyanesh N.; Varadan, Vijay K.

    2012-04-01

    Music is a powerful elicitor of emotions. Emotions evoked by music, through autonomic correlates have been shown to cause significant modulation of parameters like heart rate and blood pressure. Consequently, Heart Rate Variability (HRV) analysis can be a powerful tool to explore evidence based therapeutic functions of music and conduct empirical studies on effect of musical emotion on heart function. However, there are limitations with current studies. HRV analysis has produced variable results to different emotions evoked via music, owing to variability in the methodology and the nature of music chosen. Therefore, a pragmatic understanding of HRV correlates of musical emotion in individuals listening to specifically chosen music whilst carrying out day to day routine activities is needed. In the present study, we aim to study HRV as a single case study, using an e-bra with nano-sensors to record heart rate in real time. The e-bra developed previously, has several salient features that make it conducive for this study- fully integrated garment, dry electrodes for easy use and unrestricted mobility. The study considers two experimental conditions:- First, HRV will be recorded when there is no music in the background and second, when music chosen by the researcher and by the subject is playing in the background.

  4. Effects of Orthostatism and Hemodialysis on Mean Heart Period and Fractal Heart Rate Properties of Chronic Renal Failure Patients.

    Science.gov (United States)

    Echeverría, Juan C; Infante, Oscar; Pérez-Grovas, Héctor; González, Hortensia; José, Marco V; Lerma, Claudia

    2017-11-01

    The aim of this work was to evaluate the short-term fractal index (α 1 ) of heart rate variability (HRV) in chronic renal failure (CRF) patients by identifying the effects of orthostatism and hemodialysis (HD), and by evaluating the correlation between α 1 and the mean RR interval from sinus beats (meanNN). HRV time series were derived from ECG data of 19 CRF patients and 20 age-matched healthy subjects obtained at supine and orthostatic positions (lasting 5 min each). Data from CRF patients were collected before and after HD. α 1 was calculated from each time series and compared by analysis of variance. Pearson's correlations between meanNN and α 1 were calculated using the data from both positions by considering three groups: healthy subjects, CRF before HD and CRF after HD. At supine position, α 1 of CRF patients after HD (1.17 ± 0.30) was larger (P renal disease condition in itself. In conclusion, as in healthy subjects, α 1 of CRF patients correlates with meanNN after HD (indicating a more irregular-like HRV behavior at slower heart rates). This suggests that CRF patients with stable blood pressure preserve a regulatory adaptability despite a shifted setting point of the heart period (i.e., higher heart rate) in comparison with healthy subjects. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. Effects of heart rate on myocardial thallium-201 uptake and clearance

    International Nuclear Information System (INIS)

    Nordrehaug, J.E.; Danielsen, R.; Vik-Mo, H.

    1989-01-01

    The effects of heart rate on the myocardial uptake and clearance of 201 Tl were studied prospectively in seven healthy men, mean age 43 +/- 7 (s.d.) yr. Initial and delayed (3 hr) thallium images were obtained in three views after three bicycle exercise tests: to maximal, 80% and 60% of predicted maximal heart rate. The mean of three views initial myocardial 201 Tl uptake was higher at maximal than at both 80% and 60% of predicted maximal heart rate, being 81% (p less than 0.01) and 60% (p less than 0.01) of maximal activity, respectively. The myocardial activity in the delayed images was identical. There was a linear relationship between heart rate and the initial myocardial activity, r = 0.86 (p less than 0.001). The mean (range) 201 Tl clearance was 58% (51-65), 47% (34-56), and 34% (22-49) (all differences p less than 0.01), respectively. Concordance among the three individual views in estimating clearance was best for the highest exercise level. There was a linear relationship between heart rate and clearance, r = 0.80 (p less than 0.001). Clearance was altered by only 1.67 x 10%/heart bpm (0.024 hr/heart beat). Clearance in the liver, spleen and lungs increased at submaximal exercise levels. Thus, a linear relationship between heart rate and clearance is the result of changes in the initial exercise myocardial 201 Tl activity. Submaximal exercise may reduce reproducibility of clearance estimation, and the change of myocardial clearance with heart rate seems less than previously suggested

  6. EFFECT OF FUROSEMIDE AND TORASEMIDE ON HEART RATE VARIABILITY AND VENTRICULAR RHYTHM DISORDERS IN PATIENTS WITH CHRONIC HEART FAILURE COMPLICATING ISCHEMIC HEART DISEASE: COMPARATIVE NONRANDOMIZED STUDY

    Directory of Open Access Journals (Sweden)

    H. H. Shugushev

    2010-01-01

    Full Text Available Aim. To study effect of diuretic therapy with furosemide and torasemide on heart rate variability (HRV and frequency of ventriclar rhythm disorders in patients with chronic heart failure (CHF complicating ischemic heart disease (IHD.Material and methods. Patients (n=107 with CHF III-IV functional class (NYHA complicating IHD were examined. The first group of patients received furosemide, 20-60 mg QD (n=52, the second group received torasemide, 5-20 mg QD (n=55. Analysis of heart rhythm disorders and the basic HRV indicators was performed by ECG 10-minute recordings initially and after 10 days of therapy.Results. Decrease in time and spectral HRV parameters and increase in daily number of ventricular extrasystoles was found in furosemide treated patients. Improvement of HRV parameters and reduction of daily number of ventricular rhythm disorders was found torasemide treated patients.Conclusion. Torasemide therapy improves an autonomic regulation of heart rhythm and leads to the reduction of ventricular heart rhythm disorders in patients with CHF complicating IHD.

  7. The modulatory effects of noradrenaline on vagal control of heart rate in the dogfish, Squalus acanthias.

    Science.gov (United States)

    Agnisola, Claudio; Randall, David J; Taylor, Edwin W

    2003-01-01

    The possible interactions between inhibitory vagal control of the heart and circulating levels of catecholamines in dogfish (Squalus acanthias) were studied using an in situ preparation of the heart, which retained intact its innervation from centrally cut vagus nerves. The response to peripheral vagal stimulation typically consisted of an initial cardiac arrest, followed by an escape beat, leading to renewed beating at a mean heart rate lower than the prestimulation rate (partial recovery). Cessation of vagal stimulation led to a transient increase in heart rate, above the prestimulation rate. This whole response was completely abolished by 10(-4) M atropine (a muscarinic cholinergic antagonist). The degree of vagal inhibition was evaluated in terms of both the initial, maximal cardiac interval and the mean heart rate during partial recovery, both expressed as a percentage of the prestimulation heart rate. The mean prestimulation heart rate of this preparation (36+/-4 beats min(-1)) was not affected by noradrenaline but was significantly reduced by 10(-4) M nadolol (a beta-adrenergic receptor antagonist), suggesting the existence of a resting adrenergic tone arising from endogenous catecholamines. The degree of vagal inhibition of heart rate varied with the rate of stimulation and was increased by the presence of 10(-8) M noradrenaline (the normal in vivo level in routinely active fish), while 10(-7) M noradrenaline (the in vivo level measured in disturbed or deeply hypoxic fish) reduced the cardiac response to vagal stimulation. In the presence of 10(-7) M noradrenaline, 10(-4) M nadolol further reduced the vagal response, while 10(-4) M nadolol + 10(-4) M phentolamine had no effect, indicating a complex interaction between adrenoreceptors, possibly involving presynaptic modulation of vagal inhibition.

  8. The effect of alterations in total coenzyme A on metabolic pathways in the liver and heart

    International Nuclear Information System (INIS)

    Schlosser, C.A.S.

    1989-01-01

    The first set of experiments involved in vitro experiments using primary cultures of rat hepatocytes. A range of conditions were developed which resulted in cell cultures with variations in total CoA over a range of 1.3 to 2.9 nmol/mg protein with identical hormonal activation which simulated metabolic stress. Elevations of total CoA levels above that of controls due to preincubation with cyanamide plus pantothenate were correlated with diminished rates of total ketone body production, 3-hydroxybutyrate production and ratios of 3 hydroxybutyrate/acetoactetate with palmitate as substrate. In contrast, cells with elevated total CoA levels had higher rates of [ 14 C] CO 2 production from radioactive palmitate which implied greater flux of acetyl CoA units into the TCA cycle and less to the pathway of ketogenesis. The second set of experiments were designed to alter total CoA levels in vivo by maintaining rats on a chronic ethanol diet with or without pantothenate-supplementation. The effect of alterations of CoA on mitochondrial metabolism was evaluated by measuring substrate oxidation rates in liver and heat mitochondria as well as ketone body production with palmitoyl-1-carnitine as substrate

  9. Changes of heart rate variability and baroreflex sensitivity in patients soon after orthotopic heart transplantation

    Czech Academy of Sciences Publication Activity Database

    Fráňa, P.; Kára, T.; Souček, M.; Halámek, Josef; Řiháček, I.; Orban, O.; Toman, J.; Bartosikova, L.; Nečas, J.; Dzurova, J.

    2002-01-01

    Roč. 20, č. 4 (2002), s. S293 ISSN 0263-6352. [Scientific meeting of the international society of hypertension - european meeting on hypertension. 23.06.2002-27.06.2002, Praha] R&D Projects: GA ČR GA102/00/1262; GA ČR GA102/02/1339 Institutional research plan: CEZ:AV0Z2065902 Keywords : baroreflex * heart transplantation * ANS Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  10. Effect of Cardiac Rehabilitation on Heart Rate and Functional Capacity in Patients After Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Mandana Parvand

    2016-09-01

    Discussion: Cardiac rehabilitation can increase the performance of blood circulation and uptake of oxygen in body. Due to these changes, there was a significant increase in the functional capacity and an insignificant reduction in the heart rate.

  11. Factors that affect the variability in heart rate during endoscopic retrograde cholangiopancreatography

    DEFF Research Database (Denmark)

    Christensen, Merete; Reinert, Rebekka; Rasmussen, Verner

    2002-01-01

    OBJECTIVE: To find out if drugs, position, and endoscopic manipulation during endoscopic retrograde cholangiopancreatography (ERCP) influence the changes in the variability of heart rate. DESIGN: Single-blind randomised trial. SUBJECTS: 10 volunteers given butyscopolamine, glucagon, or saline...

  12. Time-Frequency Analysis of Terahertz Radar Signals for Rapid Heart and Breath Rate Detection

    National Research Council Canada - National Science Library

    Massar, Melody L

    2008-01-01

    We develop new time-frequency analytic techniques which facilitate the detection of a person's heart and breath rates from the Doppler shift the movement of their body induces in a terahertz radar signal...

  13. Facial electromyogram and heart-rate correlates of a paradoxical attitude change to antinuclear war information

    International Nuclear Information System (INIS)

    Vigne, J.J.; Dale, J.A.; Klions, H.L.

    1988-01-01

    The effects of film images versus film descriptions of the effects of nuclear explosions (versus a no-film control) on corrugator muscle tension, heart rate, attitude and mood were investigated. The last 5 min. of the images were associated with more corrugator tension for that condition when compared to the last 5 min. of the description condition. The groups did not differ in heart rate but women in both groups showed an increase in heart rate whereas men in both groups showed a decrease in heart rate. Film groups did not differ in their significant increases in anxiety, hostility, and depression on the Multiple Adjective Affect Checklist. On the pretest there was no significant correlation between scores on Betts' Questionnaire Upon Mental Imagery and scores on Goldenring and Doctor's index of concern for nuclear war. The vivid-image film group showed a decrease in concern for nuclear war when compared to the descriptive film group and the no-film control

  14. New descriptors of T-wave morphology are independent of heart rate

    DEFF Research Database (Denmark)

    Andersen, Mads Peter; Xue, Joel Q; Graff, Claus

    2008-01-01

    from daytime Holter recordings. Duration parameters (QT, ToTe, TpTe, and others), a number of basic T-wave morphology parameters (amplitude, area, and others) as well as advanced morphology descriptors (asymmetry, flatness, and others) were measured automatically. Heart rate dependence was examined...... by means of analysis of covariance. The results showed clear heart rate dependence for the QT interval (R(2) = 0.53-0.57) and a moderate degree of heart rate dependence for the basic morphology parameters (amplitude, area, and others) (R(2) = 0.17-0.42). Both the advanced T-wave descriptors (asymmetry......T-wave morphology descriptors are sensitive to drug-induced changes and may be a useful addition to the QT interval in cardiac safety trials. Intrasubject heart rate dependence of T-wave morphology was investigated in a sample of 39 healthy individuals. Ten-second electrocardiograms were obtained...

  15. Dogs with macroadenomas have lower body temperature and heart rate than dogs with microadenomas.

    Science.gov (United States)

    Benchekroun, Ghita; Desquilbet, Loic; Herrtage, Michael E; Jeffery, Nick D; Rosenberg, Dan; Granger, Nicolas

    2017-09-01

    Pituitary macroadenomas compress the hypothalamus, which partly regulates heart rate and body temperature. The aim of this study was to investigate whether heart rate and/or body temperature could aid in clinically differentiating dogs with macroadenomas from dogs with microadenomas (i.e. small non-compressive pituitary mass). Two groups of dogs diagnosed with pituitary-dependent hyperadrenocorticism (i.e. Cushing's disease) were included. Heart rate and body temperature were collected on initial presentation before any procedure. Dogs with macroadenoma had a significantly lower heart rate and body temperature (Pdogs with microadenoma. We suggest that the combined cut-off values of 84 beats per minutes and 38.3°C in dogs with Cushing's disease, especially with vague neurological signs (nine of 12 dogs=75%), might help to suspect the presence of a macroadenoma. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Risk Assessment of Diabetes Mellitus by Chaotic Globals to Heart Rate Variability via Six Power Spectra

    Directory of Open Access Journals (Sweden)

    Garner David M.

    2017-09-01

    Full Text Available Background: The priniciple objective here is to analyze cardiovascular dynamics in diabetic subjects by actions related to heart rate variability (HRV. The correlation of chaotic globals is vital to evaluate the probability of dynamical diseases.

  17. Effect of pre operative heart rate on post spinal hypotension in obsteric patients

    International Nuclear Information System (INIS)

    Khan, S.; Zahoor, M.U.; Zaid, A.Y.; Buland, K.

    2010-01-01

    The purpose of the study was to determine the association between of preoperative heart rate and post spinal hypotension in women undergoing cesarean section, Two hundred patients undergoing caesarean were included in the study selected on non probability convenience sampling technique, The patients were divided into two groups depending upon their pre operative heart rate. Spinal anesthesia was administered and number of patients developing hypotension was noted. Among 200 patients, who were included in the study; 112 were placed in group A and 88 were placed in group B depending on mean heart rate of 90 beats per minute or less or 91 beats per minute or more respectively. In group A 14 (11.86%) patients developed hypotension where as in group B 28 (31,82%) patients developed hypotension. Pre operative heart rate is significantly associated with post spinal hypotension in obstetric patients undergoing cesarean section. (author)

  18. Heart rate variability, sleep, and the early detection of post-traumatic stress disorder

    NARCIS (Netherlands)

    van Boxtel, Geert J.M.; Cluitmans, Pierre J.M.; Raymann, Roy J.E.M.; Ouwerkerk, Martin; Denissen, Ad J.M.; Dekker, Marian K.J.; Sitskoorn, Margriet M.; Vermetten, E.; Germain, A.; Neylan, T.C.

    2017-01-01

    Measures of heart rate variability (HRV) are sensitive indices of autonomic nervous system functioning, capable of distinguishing activity of its two constituent branches, the sympathetic and parasympathetic nervous systems. As such, these measures are possibly useful as early markers of

  19. Comparison of total artificial heart and biventricular assist device support as bridge-to-transplantation.

    Science.gov (United States)

    Cheng, Allen; Trivedi, Jaimin R; Van Berkel, Victor H; Massey, H Todd; Slaughter, Mark S

    2016-10-01

    The use of left ventricular assist devices (LVAD) has increased significantly in the last decade. However, right heart dysfunction remains a problem despite the improved outcomes with continuous-flow LVADs. Surgical options for bridge to transplantation (BTT) in patients with biventricular failure are total artificial heart (TAH) or biventricular support (BiVAD). This study examines the differences in pre- and post-transplantation outcomes and survival in patients with TAH or BiVAD support as BTT. The United Network of Organ Sharing database was retrospectively queried from January 2005 to December 2014 to identify adult patients undergoing heart transplantation (n = 17,022). Patients supported with either TAH (n = 212) or BiVAD (n = 366) at the time of transplantation were evaluated. Pre- and post-transplantation Kaplan-Meier survival curves were examined. Cox regression model was used to study the hazard ratios of the association between TAH versus BiVAD support and post-transplant survival. The median age of the study groups was 49.8 ± 12.9 (TAH) and 47.2 ± 13.9 (BiVAD) years (range 18-74 years). There were more men, 87% versus 74%, in the TAH group (p < 0.0001) with greater body mass index, 27.3 ± 5.2 versus 25.6 ± 4.7 (p < 0.0001), compared to those with BiVADs. Creatinine was higher, 1.7 + 1.2 versus 1.3 + 0.8 mg/dL (p < 0.0001), in the TAH group before transplant. The 30-day, one-, and three-year post-transplantation survival was 88%, 78%, and 67%, respectively, for patients with TAH support versus 93%, 83%, and 73% (p = 0.06) for patients with BiVAD support. Cox regression model shows pre-transplant creatinine (HR = 1.21, p = 0.008) is associated with a lower post-transplant survival. TAH is not associated with a worse post-transplant survival (p = 0.1). There was no difference in wait-list survival in patients supported with TAH or BiVAD (p = 0.8). Although there has been a recent

  20. Multi-Targeted Antithrombotic Therapy for Total Artificial Heart Device Patients.

    Science.gov (United States)

    Ramirez, Angeleah; Riley, Jeffrey B; Joyce, Lyle D

    2016-03-01

    To prevent thrombotic or bleeding events in patients receiving a total artificial heart (TAH), agents have been used to avoid adverse events. The purpose of this article is to outline the adoption and results of a multi-targeted antithrombotic clinical procedure guideline (CPG) for TAH patients. Based on literature review of TAH anticoagulation and multiple case series, a CPG was designed to prescribe the use of multiple pharmacological agents. Total blood loss, Thromboelastograph(®) (TEG), and platelet light-transmission aggregometry (LTA) measurements were conducted on 13 TAH patients during the first 2 weeks of support in our institution. Target values and actual medians for postimplant days 1, 3, 7, and 14 were calculated for kaolinheparinase TEG, kaolin TEG, LTA, and estimated blood loss. Protocol guidelines were followed and anticoagulation management reduced bleeding and prevented thrombus formation as well as thromboembolic events in TAH patients postimplantation. The patients in this study were susceptible to a variety of possible complications such as mechanical device issues, thrombotic events, infection, and bleeding. Among them all it was clear that patients were at most risk for bleeding, particularly on postoperative days 1 through 3. However, bleeding was reduced into postoperative days 3 and 7, indicating that acceptable hemostasis was achieved with the anticoagulation protocol. The multidisciplinary, multi-targeted anticoagulation clinical procedure guideline was successful to maintain adequate antithrombotic therapy for TAH patients.

  1. Operative correction of judoists’ training loads on the base of on-line monitoring of heart beats rate

    Directory of Open Access Journals (Sweden)

    Yong Qiang Liu

    2015-04-01

    Full Text Available Purpose: ensure increase of effectiveness of training process’s control by means of operative correction of training loads of different qualification judo wrestlers’ heart beats rate indicators. Material: the research was conducted on the base of Brest SCJSOR № 1. Judo wrestlers of different sport qualification (age 17-19 years old, n=15 participated in the research. Monitoring of judo wrestlers’ heart beats rate was carried out with the help of system “Polar”. Results: we have found factorial structure of functional fitness in every profile of sportsmen. Model characteristics of judo wrestlers were supplemented with the most important sides of functional fitness. Analysis of indicators of restoration effectiveness indicators (REI in both groups of judo wrestlers showed high level of organism’s responsiveness to training load of special and power orientation in comparison with speed power load. We have worked out algorithm of operative correction of training loads by indicators of heart beats rate in training process, depending on orientation and intensity of loads’ physiological influence on judo wrestler. Conclusions: Telemetric on-line monitoring of sportsman’s heart beats rate and calculation of REI permit to objectively assess effectiveness of training’s construction and of micro-cycle in total and detect in due time the trend to development of over-loading and failure of adaptation.

  2. Operative correction of judoists’ training loads on the base of on-line monitoring of heart beats rate

    Directory of Open Access Journals (Sweden)

    Liu Yong Qiang

    2015-02-01

    Full Text Available Purpose: ensure increase of effectiveness of training process’s control by means of operative correction of training loads of different qualification judo wrestlers’ heart beats rate indicators. Material: the research was conducted on the base of Brest SCJSOR № 1. Judo wrestlers of different sport qualification (age 17-19 years old, n=15 participated in the research. Monitoring of judo wrestlers’ heart beats rate was carried out with the help of system “Polar”. Results: we have found factorial structure of functional fitness in every profile of sportsmen. Model characteristics of judo wrestlers were supplemented with the most important sides of functional fitness. Analysis of indicators of restoration effectiveness indicators (REI in both groups of judo wrestlers showed high level of organism’s responsiveness to training load of special and power orientation in comparison with speed power load. We have worked out algorithm of operative correction of training loads by indicators of heart beats rate in training process, depending on orientation and intensity of loads’ physiological influence on judo wrestler. Conclusions: Telemetric on-line monitoring of sportsman’s heart beats rate and calculation of REI permit to objectively assess effectiveness of training’s construction and of micro-cycle in total and detect in due time the trend to development of over-loading and failure of adaptation.

  3. The role of physical activity and heart rate variability for the control of work related stress.

    Science.gov (United States)

    Tonello, Laís; Rodrigues, Fábio B; Souza, Jeniffer W S; Campbell, Carmen S G; Leicht, Anthony S; Boullosa, Daniel A

    2014-01-01

    Physical activity (PA) and exercise are often used as tools to reduce stress and therefore the risk for developing cardiovascular diseases (CVD). Meanwhile, heart rate variability (HRV) has been utilized to assess both stress and PA or exercise influences. The objective of the present review was to examine the current literature in regards to workplace stress, PA/exercise and HRV to encourage further studies. We considered original articles from known databases (PubMed, ISI Web of Knowledge) over the last 10 years that examined these important factors. A total of seven studies were identified with workplace stress strongly associated with reduced HRV in workers. Longitudinal workplace PA interventions may provide a means to improve worker stress levels and potentially cardiovascular risk with mechanisms still to be clarified. Future studies are recommended to identify the impact of PA, exercise, and fitness on stress levels and HRV in workers and their subsequent influence on cardiovascular health.

  4. The role of physical activity and heart rate variability for the control of work related stress

    Directory of Open Access Journals (Sweden)

    Laís eTonello

    2014-02-01

    Full Text Available Physical activity (PA and exercise are often used as tools to reduce stress and therefore the risk for developing cardiovascular diseases. Meanwhile, heart rate variability (HRV has been utilised to assess both stress and PA or exercise influences. The objective of the present mini review was to examine the current literature in regards to workplace stress, PA/exercise and HRV to encourage further studies. We considered original articles from known databases (PubMed, ISI Web of Knowledge over the last 10 years that examined these important factors. A total of 7 studies were identified with workplace stress strongly associated with reduced HRV in workers. Longitudinal workplace PA interventions may provide a means to improve worker stress levels and potentially cardiovascular risk with mechanisms still to be clarified. Future studies are recommended to identify the impact of PA, exercise and fitness on stress levels and HRV in workers and their subsequent influence on cardiovascular health.

  5. Evidence that BDNF regulates heart rate by a mechanism involving increased brainstem parasympathetic neuron excitability

    OpenAIRE

    Wan, Ruiqian; Weigand, Letitia A.; Bateman, Ryan; Griffioen, Kathleen; Mendelowitz, David; Mattson, Mark P.

    2014-01-01

    Autonomic control of heart rate is mediated by cardioinhibitory parasympathetic cholinergic neurons located in the brainstem and stimulatory sympathetic noradrenergic neurons. During embryonic development the survival and cholinergic phenotype of brainstem autonomic neurons is promoted by brain-derived neurotrophic factor (BDNF). We now provide evidence that BDNF regulates heart rate by a mechanism involving increased brainstem cardioinhibitory parasympathetic activity. Mice with a BDNF haplo...

  6. Estimating energy expenditure from heart rate in older adults: a case for calibration.

    Science.gov (United States)

    Schrack, Jennifer A; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M; Ferrucci, Luigi

    2014-01-01

    Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using different levels of calibration. Heart rate and energy expenditure were assessed across five levels of exertion in 290 adults participating in the Baltimore Longitudinal Study of Aging. Correlation and random effects regression analyses assessed the linearity of the relationship between heart rate and energy expenditure and cross-validation models assessed predictive performance. Heart rate and energy expenditure were highly correlated (r=0.98) and linear regardless of age or sex. Intra-person variability was low but inter-person variability was high, with substantial heterogeneity of the random intercept (s.d. =0.372) despite similar slopes. Cross-validation models indicated individual calibration data substantially improves accuracy predictions of energy expenditure from heart rate, reducing the potential for considerable measurement bias. Although using five calibration measures provided the greatest reduction in the standard deviation of prediction errors (1.08 kcals/min), substantial improvement was also noted with two (0.75 kcals/min). These findings indicate standard regression equations may be used to make population-level inferences when estimating energy expenditure from heart rate in older adults but caution should be exercised when making inferences at the individual level without proper calibration.

  7. Heart-Rate Recovery Index Is Impaired in Behçet's Disease

    Science.gov (United States)

    Kaya, Ergun Baris; Yorgun, Hikmet; Akdogan, Ali; Ates, Ahmet Hakan; Canpolat, Ugur; Sunman, Hamza; Aytemir, Kudret; Tokgozoglu, Lale; Kabakci, Giray; Calguneri, Meral; Ozkutlu, Hilmi; Oto, Ali

    2009-01-01

    Behçet's disease, a multisystemic inflammatory disorder, has been associated with a number of cardiovascular dysfunctions, including ventricular arrhythmias and sudden cardiac death. Heart-rate recovery after exercise can provide both an estimate of impaired parasympathetic tone and a prognosis in regard to all-cause and cardiovascular death. The aim of our study was to evaluate heart-rate recovery in Behçet's disease From January through July 2008, we examined at our outpatient clinic and prospectively enrolled 30 consecutive patients with Behçet's disease and 50 healthy control participants who were matched for age and sex. Basal electrocardiography, echocardiography, and treadmill exercise testing were performed in all patients and control participants. The heart-rate recovery index was calculated in the usual manner, by subtracting the 1st-minute (Rec1), 2nd-minute (Rec2), and 3rd-minute (Rec3) recovery heart rates from the maximal heart rate after exercise stress testing. Patients with Behçet's disease exhibited significantly lower heart-rate recovery numbers, compared with healthy control participants: Rec1, 24.28 ± 8.2 vs 34.4 ± 7.6, P = 0.002; Rec2, 49.28 ± 11.2 vs 57.5 ± 7.0, P < 0.05; and Rec3, 56.2 ± 12.11 vs 67.4 ± 8.7, P = 0.014. To our knowledge, this is the 1st study that shows an impaired heart-rate recovery index (indicative of reduced parasympathetic activity) among patients with Behçet's disease. Given the independent prognostic value of the heart-rate recovery index, our results may explain the increased occurrence of arrhythmias and sudden cardiac death in Behçet's patients. Therefore, this index may be clinically useful in the identification of high-risk patients. PMID:19693299

  8. Heart rate variability in normal-weight patients with polycystic ovary syndrome

    OpenAIRE

    Kilit, Celal; Kilit, T?rkan Pa?al?

    2017-01-01

    Objective: Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. Methods: We examined the heart rate va...

  9. Design of a heart rate controller for treadmill exercise using a recurrent fuzzy neural network.

    Science.gov (United States)

    Lu, Chun-Hao; Wang, Wei-Cheng; Tai, Cheng-Chi; Chen, Tien-Chi

    2016-05-01

    In this study, we developed a computer controlled treadmill system using a recurrent fuzzy neural network heart rate controller (RFNNHRC). Treadmill speeds and inclines were controlled by corresponding control servo motors. The RFNNHRC was used to generate the control signals to automatically control treadmill speed and incline to minimize the user heart rate deviations from a preset profile. The RFNNHRC combines a fuzzy reasoning capability to accommodate uncertain information and an artificial recurrent neural network learning process that corrects for treadmill system nonlinearities and uncertainties. Treadmill speeds and inclines are controlled by the RFNNHRC to achieve minimal heart rate deviation from a pre-set profile using adjustable parameters and an on-line learning algorithm that provides robust performance against parameter variations. The on-line learning algorithm of RFNNHRC was developed and implemented using a dsPIC 30F4011 DSP. Application of the proposed control scheme to heart rate responses of runners resulted in smaller fluctuations than those produced by using proportional integra control, and treadmill speeds and inclines were smoother. The present experiments demonstrate improved heart rate tracking performance with the proposed control scheme. The RFNNHRC scheme with adjustable parameters and an on-line learning algorithm was applied to a computer controlled treadmill system with heart rate control during treadmill exercise. Novel RFNNHRC structure and controller stability analyses were introduced. The RFNNHRC were tuned using a Lyapunov function to ensure system stability. The superior heart rate control with the proposed RFNNHRC scheme was demonstrated with various pre-set heart rates. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Parasympathetic neural activity accounts for the lowering of exercise heart rate at high altitude

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Calbet, J A; Rådegran, G

    2001-01-01

    In chronic hypoxia, both heart rate (HR) and cardiac output (Q) are reduced during exercise. The role of parasympathetic neural activity in lowering HR is unresolved, and its influence on Q and oxygen transport at high altitude has never been studied.......In chronic hypoxia, both heart rate (HR) and cardiac output (Q) are reduced during exercise. The role of parasympathetic neural activity in lowering HR is unresolved, and its influence on Q and oxygen transport at high altitude has never been studied....

  11. Buccal telomere length and its associations with cortisol, heart rate variability, heart rate, and blood pressure responses to an acute social evaluative stressor in college students.

    Science.gov (United States)

    Woody, Alex; Hamilton, Katrina; Livitz, Irina E; Figueroa, Wilson S; Zoccola, Peggy M

    2017-05-01

    Understanding the relationship between stress and telomere length (a marker of cellular aging) is of great interest for reducing aging-related disease and death. One important aspect of acute stress exposure that may underlie detrimental effects on health is physiological reactivity to the stressor. This study tested the relationship between buccal telomere length and physiological reactivity (salivary cortisol reactivity and total output, heart rate (HR) variability, blood pressure, and HR) to an acute psychosocial stressor in a sample of 77 (53% male) healthy young adults. Consistent with predictions, greater reductions in HR variability (HRV) in response to a stressor and greater cortisol output during the study session were associated with shorter relative buccal telomere length (i.e. greater cellular aging). However, the relationship between cortisol output and buccal telomere length became non-significant when adjusting for medication use. Contrary to past findings and study hypotheses, associations between cortisol, blood pressure, and HR reactivity and relative buccal telomere length were not significant. Overall, these findings may indicate there are limited and mixed associations between stress reactivity and telomere length across physiological systems.

  12. Quantification of total mercury in liver and heart tissue of Harbor Seals (Phoca vitulina) from Alaska USA

    International Nuclear Information System (INIS)

    Marino, Kady B.; Hoover-Miller, Anne; Conlon, Suzanne; Prewitt, Jill; O'Shea, Stephen K.

    2011-01-01

    This study quantified the Hg levels in the liver (n=98) and heart (n=43) tissues of Harbor Seals (Phoca vitulina) (n=102) harvested from Prince William Sound and Kodiak Island Alaska. Mercury tissue dry weight (dw) concentrations in the liver ranged from 1.7 to 393 ppm dw, and in the heart from 0.19 to 4.99 ppm dw. Results of this study indicate liver and heart tissues' Hg ppm dw concentrations significantly increase with age. Male Harbor Seals bioaccumulated Hg in both their liver and heart tissues at a significantly faster rate than females. The liver Hg bioaccumulation rates between the harvest locations Kodiak Island and Prince William Sound were not found to be significantly different. On adsorption Hg is transported throughout the Harbor Seal's body with the partition coefficient higher for the liver than the heart. No significant differences in the bio-distribution (liver:heart Hg ppm dw ratios (n=38)) values were found with respect to either age, sex or geographic harvest location. In this study the age at which Hg liver and heart bioaccumulation levels become significantly distinct in male and female Harbor Seals were identified through a Tukey's analysis. Of notably concern to human health was a male Harbor Seal's liver tissue harvested from Kodiak Island region. Mercury accumulation in this sample tissue was determined through a Q-test to be an outlier, having far higher Hg concentrarion (liver 392 Hg ppm dw) than the general population sampled. - Highlights: ► Mercury accumulation in the liver and heart of seals exceed food safety guidelines. ► Accumulation rate is greater in males than females with age. ► Liver mercury accumulation is greater than in the heart tissues. ► Mercury determination by USA EPA Method 7473 using thermal decomposition.

  13. Activity and heart rate in semi-domesticated reindeer during adaptation to emergency feeding.

    Science.gov (United States)

    Nilsson, A; Ahman, B; Norberg, H; Redbo, I; Eloranta, E; Olsson, K

    2006-06-15

    Although reindeer are well adapted to limited food resources during winter, semi-domesticated reindeer are regularly fed when snow conditions are bad in order to prevent starvation. Feeding sometimes results in health problems and loss of animals. This study was made to assess if activity pattern in reindeer could be used as a tool for the reindeer herder in early detection of animals that are not adapting to feeding. The frequency of 10 behavioural categories was recorded in five groups of penned, eight-month-old, female semi-domesticated reindeer. Three reindeer per group were fitted with heart rate monitors. Lying was the most frequent behaviour, whilst there were few cases of agonistic behaviour. Heart rate varied during the day, with peaks during feeding and low heart rates in the early morning. Restricted feed intake resulted in more locomotion and seeking but less ruminating compared to feeding ad libitum. This was followed by a generally lower heart rate in reindeer in the restricted groups compared to controls. Subsequent feeding with different combinations of lichens, silage and pellets ad libitum resulted initially in significantly more of the animals lying curled up, compared to controls, combined with increased heart rates. As the experiment continued the general activity pattern, as well as the heart rate, gradually became more similar in all groups. Lying curled was the behavioural indicator most consistently affected by feed deprivation and adaptation to feeding and may thus be a useful indicator to distinguish individual reindeer that are not adjusting to feeding.

  14. Heart rate profiles and energy cost of locomotion during cross-country skiing races.

    Science.gov (United States)

    Mognoni, P; Rossi, G; Gastaldelli, F; Canclini, A; Cotelli, F

    2001-07-01

    The purpose of this study was to compare heart rate responses and speed in two cross-country skiing races, which were run by seven male and seven female subjects by using classic and free style. Heart rates and skiing velocities were analyzed over flat, uphill and downhill sections, which were run from one to three times. Heart rates were higher in uphill sections than in flat sections; a steady-state heart rate was never reached in the downhill section. When the same uphill section was repeated, the heart rate tended to increase but the speed to decrease. Oxygen uptake (VO2) was calculated from heart rate:VO2 ratio, measured during uphill walking with the aid of poles. The mean (SD) energy cost of locomotion (i.e., the ratio between net VO2 and speed) was 162.1 (9.4) ml.km(-1).kg(-1) and 147.7 (7.1) ml.km(-1).kg(-1) when male subjects ran the flat section after first downhill by using classic and free style, respectively. Females had lower values for VO2 and speed, but similar energy costs. In general, the variability of the energy cost of locomotion in skiers of a similar competitive level is of the same order as that found in uphill walking on a treadmill.

  15. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography.

    Science.gov (United States)

    Laspas, Fotios; Tsantioti, Dimitra; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John

    2011-04-01

    Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.

  16. Aerobic exercise during pregnancy and presence of fetal-maternal heart rate synchronization.

    Directory of Open Access Journals (Sweden)

    Peter Van Leeuwen

    Full Text Available It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization.In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance.In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data.The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates.

  17. Aerobic exercise during pregnancy and presence of fetal-maternal heart rate synchronization.

    Science.gov (United States)

    Van Leeuwen, Peter; Gustafson, Kathleen M; Cysarz, Dirk; Geue, Daniel; May, Linda E; Grönemeyer, Dietrich

    2014-01-01

    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates.

  18. Aerobic Exercise during Pregnancy and Presence of Fetal-Maternal Heart Rate Synchronization

    Science.gov (United States)

    Van Leeuwen, Peter; Gustafson, Kathleen M.; Cysarz, Dirk; Geue, Daniel; May, Linda E.; Grönemeyer, Dietrich

    2014-01-01

    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. Methods In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. Results In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. Conclusion The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates. PMID:25162592

  19. Exploratory multivariate analysis of the effect of fatty fish consumption and medicinal use on heart rate and heart rate variability data

    Directory of Open Access Journals (Sweden)

    Bjorn eGrung

    2015-02-01

    Full Text Available The overall aim of the present study was to explore the relationship between medicinal use and fatty fish consumption on heart rate variability (HRV and heart rate (HR in a group of forensic inpatients on a variety of medications. A total of 49 forensic inpatients, randomly assigned to a fish group (n=27 or a control group (n=22 were included in the present study. Before and by the end of the food intervention period HR and HRV were measured during an experimental test procedure. An additional aim of this paper is to show how multivariate data analysis can highlight differences and similarities between the groups, thus being a valuable addition to traditional statistical hypothesis testing. The results indicate that fish consumption may have a positive effect on both HR and HRV regardless of medication, but that the influence of medication is strong enough to mask the true effect of fish consumption. Without correcting for medication, the fish group and control group become indistinguishable (p = 0.0794, Cohen’s d = 0.60. The effect of medication is demonstrated by establishing a multivariate regression model that estimates HR and HRV in a recovery phase based on HR and HRV data recorded during psychological tests. The model performance is excellent for HR data, but yields poor results for HRV when employed on participants undergoing the more severe medical treatments. This indicates that the HRV behavior of this group is very different from that of the participants on no or lower level of medication. When focusing on the participants on a constant medication regime, a substantial improvement in HRV and HR for the fish group compared to the control group is indicated by a principal component analysis and t tests (p = 0.00029, Cohen’s d = 2.72. In a group of psychiatric inpatients characterized by severe mental health problems consuming different kinds of medication, the fish diet improved HR and HRV, indices of both emotional regulation and

  20. The effect of orthostatic stress on multiscale entropy of heart rate and blood pressure

    International Nuclear Information System (INIS)

    Turianikova, Zuzana; Javorka, Kamil; Calkovska, Andrea; Javorka, Michal; Baumert, Mathias

    2011-01-01

    Cardiovascular control acts over multiple time scales, which introduces a significant amount of complexity to heart rate and blood pressure time series. Multiscale entropy (MSE) analysis has been developed to quantify the complexity of a time series over multiple time scales. In previous studies, MSE analyses identified impaired cardiovascular control and increased cardiovascular risk in various pathological conditions. Despite the increasing acceptance of the MSE technique in clinical research, information underpinning the involvement of the autonomic nervous system in the MSE of heart rate and blood pressure is lacking. The objective of this study is to investigate the effect of orthostatic challenge on the MSE of heart rate and blood pressure variability (HRV, BPV) and the correlation between MSE (complexity measures) and traditional linear (time and frequency domain) measures. MSE analysis of HRV and BPV was performed in 28 healthy young subjects on 1000 consecutive heart beats in the supine and standing positions. Sample entropy values were assessed on scales of 1–10. We found that MSE of heart rate and blood pressure signals is sensitive to changes in autonomic balance caused by postural change from the supine to the standing position. The effect of orthostatic challenge on heart rate and blood pressure complexity depended on the time scale under investigation. Entropy values did not correlate with the mean values of heart rate and blood pressure and showed only weak correlations with linear HRV and BPV measures. In conclusion, the MSE analysis of heart rate and blood pressure provides a sensitive tool to detect changes in autonomic balance as induced by postural change

  1. Does treadmill running performance, heart rate and breathing rate response during maximal graded exercise improve after volitional respiratory muscle training?

    Science.gov (United States)

    Radhakrishnan, K; Sharma, V K; Subramanian, S K

    2017-05-10

    Maximal physical exertion in sports usually causes fatigue in the exercising muscles, but not in the respiratory muscles due to triggering of the Respiratory muscle metabo-reflex, a sympathetic vasoconstrictor response leading to preferential increment in blood flow to respiratory muscles. 1 We planned to investigate whether a six week yogic pranayama based Volitional Respiratory Muscle Training (VRMT) can improve maximal Graded Exercise Treadmill Test (GXTT) performance in healthy adult recreational sportspersons. Consecutive, consenting healthy adult recreational sportspersons aged 20.56±2.49 years (n=30), volunteered to 'baseline recording' of resting heart rate (HR), blood pressure (BP), respiratory rate (RR), and Bruce ramp protocol maximal GXTT until volitional exhaustion providing total test time (TTT), derived VO2max, Metabolic Equivalent of Task (METs), HR and BP response during maximal GXTT and drop in recovery HR data. After six weeks of observation, they underwent 'pre-intervention recording' followed by supervised VRMT intervention for 6 weeks (30 minutes a day; 5 days a week) and then 'post-intervention recording'. Repeated measures ANOVA with pairwise t statistical comparison was used to analyse the data. After supervised VRMT, we observed significant decrease in their resting supine RR (prespiratory muscle aerobic capacity, attenuation of respiratory muscle metabo-reflex, increase in cardiac stroke volume and autonomic resetting towards parasympatho-dominance. Yogic Pranayama based VRMT can be used in sports conditioning programme of athletes to further improve their maximal exercise performance, and as part of rehabilitation training during return from injury.

  2. Heart Rate and Oxygen Uptake Recovery and the Level of Aerobic Capacity in Mountain Bikers

    Directory of Open Access Journals (Sweden)

    Michalik Kamil

    2017-12-01

    Full Text Available Introduction. Since mountain biking involves exercise of varying intensity, competitive performance may be affected by the rate of recovery. The aim of the current study was to determine whether maximal oxygen uptake is associated with the rate of heart rate and oxygen uptake recovery in mountain bike athletes.

  3. Heart Rate Variability Responses of Individuals With and Without Saline-Induced Obstructive Sleep Apnea.

    Science.gov (United States)

    Vena, Daniel; Bradley, T Douglas; Millar, Philip J; Floras, John S; Rubianto, Jonathan; Gavrilovic, Bojan; Perger, Elisa; Yadollahi, Azadeh

    2018-03-30

    Postoperative development of obstructive sleep apnea (OSA) has been attributed to the fluid overloaded state of patients during the postoperative period. In this context, alterations in cardiac autonomic regulation caused by OSA may explain the increased postoperative risk for adverse cardiovascular events. This study tests the hypothesis that individuals with fluid overload-induced OSA will experience autonomic dysregulation, compared to those without fluid overload-induced OSA. Twenty-one normotensive, nonobese (mean body mass index 24.5 kg/m2) males (mean age 37 years) underwent a sleep study. Participants were randomly assigned to infusion with saline during sleep either at the minimum rate (control) or as a bolus of 22 mL/kg body weight (intervention). Participants were blinded to the intervention and crossed over to the other study arm after 1 week. Measures of heart rate variability were calculated from electrocardiography recordings presaline and postsaline infusion in the intervention arm. Heart rate variability measures computed were: standard deviation of the RR interval; root mean square of successive differences; low-frequency, high-frequency, and total power; and the ratio of low-frequency to high-frequency power. Although presaline infusion values were similar, postsaline infusion values of the standard deviation of the RR interval and high-frequency power were lower in the group whose apnea-hypopnea index increased in response to saline infusion, compared to the group whose apnea-hypopnea index did not increase in response to saline infusion ( P variability, consistent with vagal withdrawal. Future work should explore autonomic dysregulation in the postoperative period and its association with adverse events. Copyright © 2018 American Academy of Sleep Medicine. All rights reserved.

  4. Effects of hot-iron branding on heart rate, breathing rate and behaviour of anaesthetised Steller sea lions.

    Science.gov (United States)

    Walker, K A; Mellish, J E; Weary, D M

    2011-10-01

    This study assessed the heart rate, breathing rate and behavioural responses of 12 juvenile Steller sea lions during hot-iron branding under isoflurane anaesthesia. Physiological and behavioural measures were recorded in four periods: baseline (five minutes), sham branding (one minute), branding (approximately 2.7 minutes) and postbranding (five minutes). No difference in heart rate was noted from baseline to sham branding, but heart rate increased from mean (sem) 78.3 (2.4) bpm in the baseline period to 85.6 (2.5) bpm in the branding period. Heart rate remained elevated in the postbranding period, averaging 84.7 (2.5) bpm. Breathing rate averaged 2.5 (1.0) breaths/minute in the baseline and sham branding periods increased to 8.9 (1.0) breaths/minute during branding, but returned to baseline by the postbranding period. Behaviourally, half of the sea lions exhibited trembling and head and shoulder movements during branding.

  5. Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices.

    Science.gov (United States)

    Braga, Lays Magalhães; Prado, Gustavo Faibischew; Umeda, Iracema Ioco Kikuchi; Kawauchi, Tatiana Satie; Taboada, Adriana Marques Fróes; Azevedo, Raymundo Soares; Pereira Filho, Horacio Gomes; Grupi, César José; Souza, Hayala Cristina Cavenague; Moreira, Dalmo Antônio Ribeiro; Nakagawa, Naomi Kondo

    2016-01-01

    Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86rates, a small effect in increasing differences between Holter and Polar in R-R intervals was observed. In conclusion, our study showed good reproducibility of HRV at rest in two consecutive 6MW using Holter and PolarS810i. Additionally, PolarS810i produced good agreements in short-term HRV indices based on Holter simultaneous recordings at rest, during the 6MW and recovery in HF patients.

  6. Influence of different characteristics of sport on heart rate recovery in elite athletes

    Directory of Open Access Journals (Sweden)

    Anđić Radovan

    2016-01-01

    Full Text Available Introduction: One of the benefits of regular physical activity is lower resting heart rate and its faster recovery after maximal exercise test, as a result of a stronger parasympatic (vagal tone. Heart rate recovery is used as reliable parameter for prescription of the training program and also in prognostic purposes as a parameter of risk for developing cardiovascular diseases. Aim: The purpose of this study is to show significant differences in heart rate recovery after maximal exercise test and resting heart rate among different groups of elite athletes. Material and Methods: This study subjected 575 adult (23.1 ± 4.3 years, male athletes divided into four sport groups: skill, power, mixed and endurance. Every subject performed progressive, maximal cardiopulmonary exercise test on a treadmill. Heart rate recovery in first (ΔHRR1 and third (ΔHRR3 minute was calculated as a difference of maximal heart rate and heart rate in the first and the third minute after cessation of exercise, respectively. Results: Compared to skill, power and mixed group (62.9 ± 11.4; 61.5 ± 10.0; 59.9 ± 10.4 min-1 respectively, significantly lower values od resting heart rate are recorded in the endurance group (56.2 ± 10.6 min-1 (p = 0,05. Also, ΔHRR1 was significantly higher in the endurance group (33.5 ±14.3 min-1 compared to skill, power and mixed group (24.3 ± 10.9; 25.5 ± 11.2; 27.8 ± 15.6 min-1 respectively (p = 0,05. Values od ΔHRR3 were significantly higher in power, mixed and endurance groups (74.8 ± 14.3; 79.5 ± 12.7; 79.4 ± 12.6 min-1 respectively compared to skill group (67.3±16.1 min-1 (p = 0,05. Conclusion: Training endurance group of sports has the most contribution to lower resting heart rate and faster recovery of heart rate in the first minute after exercising, due to dominant parasympatic tone.

  7. Electromagnetic Compatibility of Transcutaneous Energy Transmission Systemfor Totally Implantable Artificial Heart

    Science.gov (United States)

    Shiba, Kenji; Koshiji, Kohji

    Transcutaneous Energy Transmission (TET) is one way of providing the energy needed to power a totally implantable artificial heart (TIAH). In the present study, an externally coupled TET system was implanted in a prototype human phantom to evaluate emission and immunity. In the emission evaluation, measurements were conducted based on CISPR Pub.11 and VDE 0871 standards, while immunity tests were based on the standards of the IEC 61000-4 series. The magnetic field of the radiated emission was measured using a loop antenna. At 0.1[MHz], we found the greatest magnetic field of 47.8 [dBμA/m], somewhat less than CISPR’s upper limit of 54 [dBμA/m]. For the conducted emission, by installing a noise filter and ferrite beads in the input section of the DC-power supply, conducted emission could be kept within the allowable limits of CISPR Pub.11 and VDE 0871. Finally, the immunity tests against radiated and conducted emission, electrostatic discharge and voltage fluctuation proved that the prototype could withstand the maximum level of disturbance. These results confirmed that the TET system implanted in a human phantom could, through modification, meet the emission and immunity standards.

  8. Driver electronics design and control for a total artificial heart linear motor.

    Science.gov (United States)

    Unthan, Kristin; Cuenca-Navalon, Elena; Pelletier, Benedikt; Finocchiaro, Thomas; Steinseifer, Ulrich

    2018-01-27

    For any implantable device size and efficiency are critical properties. Thus, a linear motor for a Total Artificial Heart was optimized with focus on driver electronics and control strategies. Hardware requirements were defined from power supply and motor setup. Four full bridges were chosen for the power electronics. Shunt resistors were set up for current measurement. Unipolar and bipolar switching for power electronics control were compared regarding current ripple and power losses. Here, unipolar switching showed smaller current ripple and required less power to create the necessary motor forces. Based on calculations for minimal power losses Lorentz force was distributed to the actor's four coils. The distribution was determined as ratio of effective magnetic flux through each coil, which was captured by a force test rig. Static and dynamic measurements under physiological conditions analyzed interaction of control and hardware and all efficiencies were over 89%. In conclusion, the designed electronics, optimized control strategy and applied current distribution create the required motor force and perform optimal under physiological conditions. The developed driver electronics and control offer optimized size and efficiency for any implantable or portable device with multiple independent motor coils. Graphical Abstract ᅟ.

  9. Generating pulsatility by pump speed modulation with continuous-flow total artificial heart in awake calves.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Karimov, Jamshid H; Sunagawa, Gengo; Horvath, David J; Byram, Nicole; Kuban, Barry D; Dessoffy, Raymond; Sale, Shiva; Golding, Leonard A R; Moazami, Nader

    2017-12-01

    The purpose of this study was to evaluate the effects of sinusoidal pump speed modulation of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) on hemodynamics and pump flow in an awake chronic calf model. The sinusoidal pump speed modulations, performed on the day of elective sacrifice, were set at ±15 and ± 25% of mean pump speed at 80 bpm in four awake calves with a CFTAH. The systemic and pulmonary arterial pulse pressures increased to 12.0 and 12.3 mmHg (±15% modulation) and to 15.9 and 15.7 mmHg (±25% modulation), respectively. The pulsatility index and surplus hemodynamic energy significantly increased, respectively, to 1.05 and 1346 ergs/cm at ±15% speed modulation and to 1.51 and 3381 ergs/cm at ±25% speed modulation. This study showed that it is feasible to generate pressure pulsatility with pump speed modulation; the platform is suitable for evaluating the physiologic impact of pulsatility and allows determination of the best speed modulations in terms of magnitude, frequency, and profiles.

  10. Application of Adaptive Starling-Like Controller to Total Artificial Heart Using Dual Rotary Blood Pumps.

    Science.gov (United States)

    Ng, Boon C; Smith, Peter A; Nestler, Frank; Timms, Daniel; Cohn, William E; Lim, Einly

    2017-03-01

    The successful clinical applicability of rotary left ventricular assist devices (LVADs) has led to research interest in devising a total artificial heart (TAH) using two rotary blood pumps (RBPs). The major challenge when using two separately controlled LVADs for TAH support is the difficulty in maintaining the balance between pulmonary and systemic blood flows. In this study, a starling-like controller (SLC) hybridized with an adaptive mechanism was developed for a dual rotary LVAD TAH. The incorporation of the adaptive mechanism was intended not only to minimize the risk of pulmonary congestion and atrial suction but also to match cardiac demand. A comparative assessment was performed between the proposed adaptive starling-like controller (A-SLC) and a conventional SLC as well as a constant speed controller. The performance of all controllers was evaluated by subjecting them to three simulated scenarios [rest, exercise, head up tilt (HUT)] using a mock circulation loop. The overall results showed that A-SLC was superior in matching pump flow to cardiac demand without causing hemodynamic instabilities. In contrast, improper flow regulation by the SLC resulted in pulmonary congestion during exercise. From resting supine to HUT, overpumping of the RBPs at fixed speed (FS) caused atrial suction, whereas implementation of SLC resulted in insufficient flow. The comparative study signified the potential of the proposed A-SLC for future TAH implementation particularly among outpatients, who are susceptible to variety of clinical scenarios.

  11. Deairing Techniques for Double-Ended Centrifugal Total Artificial Heart Implantation.

    Science.gov (United States)

    Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Grady, Patrick; Sinkewich, Martin; Moazami, Nader; Sale, Shiva; Golding, Leonard A R; Fukamachi, Kiyotaka

    2017-06-01

    The unique device architecture of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) requires dedicated and specific air-removal techniques during device implantation in vivo. These procedures comprise special surgical techniques and intraoperative manipulations, as well as engineering design changes and optimizations to the device itself. The current study evaluated the optimal air-removal techniques during the Cleveland Clinic double-ended centrifugal CFTAH in vivo implants (n = 17). Techniques and pump design iterations consisted of developing a priming method for the device and the use of built-in deairing ports in the early cases (n = 5). In the remaining cases (n = 12), deairing ports were not used. Dedicated air-removal ports were not considered an essential design requirement, and such ports may represent an additional risk for pump thrombosis. Careful passive deairing was found to be an effective measure with a centrifugal pump of this design. In this report, the techniques and design changes that were made during this CFTAH development program to enable effective residual air removal and prevention of air embolism during in vivo device implantation are explained. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Median Sternotomy or Right Thoracotomy Techniques for Total Artificial Heart Implantation in Calves.

    Science.gov (United States)

    Karimov, Jamshid H; Moazami, Nader; Sunagawa, Gengo; Kobayashi, Mariko; Byram, Nicole; Sale, Shiva; Such, Kimberly A; Horvath, David J; Golding, Leonard A R; Fukamachi, Kiyotaka

    2016-10-01

    The choice of optimal operative access technique for mechanical circulatory support device implantation ensures successful postoperative outcomes. In this study, we retrospectively evaluated the median sternotomy and lateral thoracotomy incisions for placement of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) in a bovine model. The CFTAH was implanted in 17 calves (Jersey calves; weight range, 77.0-93.9 kg) through a median sternotomy (n = 9) or right thoracotomy (n = 8) for elective chronic implantation periods of 14, 30, or 90 days. Similar preoperative preparation, surgical techniques, and postoperative care were employed. Implantation of the CFTAH was successfully performed in all cases. Both methods provided excellent surgical field visualization. After device connection, however, the median sternotomy approach provided better visualization of the anastomoses and surgical lines for hemostasis confirmation and repair due to easier device displacement, which is severely limited following right thoracotomy. All four animals sacrificed after completion of the planned durations (up to 90 days) were operated through full median sternotomy. Our data demonstrate that both approaches provide excellent initial field visualization. Full median sternotomy provides larger viewing angles at the anastomotic suture line after device connection to inflow and outflow ports. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. Chronic intermittent hypoxia-hypercapnia blunts heart rate responses and alters neurotransmission to cardiac vagal neurons.

    Science.gov (United States)

    Dyavanapalli, Jhansi; Jameson, Heather; Dergacheva, Olga; Jain, Vivek; Alhusayyen, Mona; Mendelowitz, David

    2014-07-01

    Patients with obstructive sleep apnoea experience chronic intermittent hypoxia-hypercapnia (CIHH) during sleep that elicit sympathetic overactivity and diminished parasympathetic activity to the heart, leading to hypertension and depressed baroreflex sensitivity. The parasympathetic control of heart rate arises from pre-motor cardiac vagal neurons (CVNs) located in nucleus ambiguus (NA) and dorsal motor nucleus of the vagus (DMNX). The mechanisms underlying diminished vagal control of heart rate were investigated by studying the changes in blood pressure, heart rate, and neurotransmission to CVNs evoked by acute hypoxia-hypercapnia (H-H) and CIHH. In vivo telemetry recordings of blood pressure and heart rate were obtained in adult rats during 4 weeks of CIHH exposure. Retrogradely labelled CVNs were identified in an in vitro brainstem slice preparation obtained from adult rats exposed either to air or CIHH for 4 weeks. Postsynaptic inhibitory or excitatory currents were recorded using whole cell voltage clamp techniques. Rats exposed to CIHH had increases in blood pressure, leading to hypertension, and blunted heart rate responses to acute H-H. CIHH induced an increase in GABAergic and glycinergic neurotransmission to CVNs in NA and DMNX, respectively; and a reduction in glutamatergic neurotransmission to CVNs in both nuclei. CIHH blunted the bradycardia evoked by acute H-H and abolished the acute H-H evoked inhibition of GABAergic transmission while enhancing glycinergic neurotransmission to CVNs in NA. These changes with CIHH inhibit CVNs and vagal outflow to the heart, both in acute and chronic exposures to H-H, resulting in diminished levels of cardioprotective parasympathetic activity to the heart as seen in OSA patients. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  14. Effect of a telemonitoring-facilitated collaboration between general practitioner and heart failure clinic on mortality and rehospitalization rates in severe heart failure: the TEMA-HF 1 (TElemonitoring in the MAnagement of Heart Failure) study.

    Science.gov (United States)

    Dendale, Paul; De Keulenaer, Gilles; Troisfontaines, Pierre; Weytjens, Caroline; Mullens, Wilfried; Elegeert, Ivan; Ector, Bavo; Houbrechts, Marita; Willekens, Koen; Hansen, Dominique

    2012-03-01

    Chronic heart failure (CHF) patients are frequently rehospitalized within 6 months after an episode of fluid retention. Rehospitalizations are preventable, but this requires an extensive organization of the healthcare system. In this study, we tested whether intensive follow-up of patients through a telemonitoring-facilitated collaboration between general practitioners (GPs) and a heart failure clinic could reduce mortality and rehospitalization rate. One hunderd and sixty CHF patients [mean age 76 ± 10 years, 104 males, mean left ventricular ejection fraction (LVEF) 35 ± 15%] were block randomized by sealed envelopes and assigned to 6 months of intense follow-up facilitated by telemonitoring (TM) or usual care (UC). The TM group measured body weight, blood pressure, and heart rate on a daily basis with electronic devices that transferred the data automatically to an online database. Email alerts were sent to the GP and heart failure clinic to intervene when pre-defined limits were exceeded. All-cause mortality was significantly lower in the TM group as compared with the UC group (5% vs. 17.5%, P = 0.01). The total number of follow-up days lost to hospitalization, dialysis, or death was significantly lower in the TM group as compared with the UC group (13 vs. 30 days, P = 0.02). The number of hospitalizations for heart failure per patient showed a trend (0.24 vs. 0.42 hospitalizations/patient, P = 0.06) in favour of TM. Telemonitoring-facilitated collaboration between GPs and a heart failure clinic reduces mortality and number of days lost to hospitalization, death, or dialysis in CHF patients. These findings need confirmation in a large trial.

  15. Combinatorial effect of nicotine and black tea on heart rate variability: Useful or harmful?

    Science.gov (United States)

    Joukar, S; Sheibani, M

    2017-06-01

    The effect of nicotine on heart rate variability (HRV) is controversial. Autonomic nervous system is the main regulator of heart rhythm, and heart rate variability is an appropriate index to assessment of the effects of the autonomic system on heart. In this study, the combination effect of nicotine and black tea consumption on sympatho-vagal balance and heart rate variability was investigated in rats. Male Wistar rats were randomized into four groups as control, tea (2.5 g/100 cc, daily), nicotine (2 mg/kg/d) and tea plus nicotine groups which treated for 28 days, and in the 29th day, their electrocardiograms (lead II) were recorded. The mean of high-frequency power (HF) in tea, nicotine and tea plus nicotine groups was significantly more than control group (P nicotine and tea + nicotine groups was significantly less than control group (P nicotine and tea + nicotine groups in comparison with control group (P nicotine or their combination with dosages used in this study can increase the heart rate variability and improve the sympatho-vagal balance in rat. © 2017 John Wiley & Sons Ltd.

  16. Allostatic load and heart rate variability as health risk indicators.

    African Journals Online (AJOL)

    investigate the feasibility of inclusion of HRV indicators into allostatic load assessments and which HRV ... said to reflect stressor-induced activation of the two ... reduced in stress and said to be of prognostic value for ... Recruitment by a power point-illustrat- .... values (Total HRV and vagal activity dependent HRV) can.

  17. Office and 24-hour heart rate and target organ damage in hypertensive patients

    Directory of Open Access Journals (Sweden)

    García-García Ángel

    2012-03-01

    Full Text Available Abstract Background We investigated the association between heart rate and its variability with the parameters that assess vascular, renal and cardiac target organ damage. Methods A cross-sectional study was performed including a consecutive sample of 360 hypertensive patients without heart rate lowering drugs (aged 56 ± 11 years, 64.2% male. Heart rate (HR and its standard deviation (HRV in clinical and 24-hour ambulatory monitoring were evaluated. Renal damage was assessed by glomerular filtration rate and albumin/creatinine ratio; vascular damage by carotid intima-media thickness and ankle/brachial index; and cardiac damage by the Cornell voltage-duration product and left ventricular mass index. Results There was a positive correlation between ambulatory, but not clinical, heart rate and its standard deviation with glomerular filtration rate, and a negative correlation with carotid intima-media thickness, and night/day ratio of systolic and diastolic blood pressure. There was no correlation with albumin/creatinine ratio, ankle/brachial index, Cornell voltage-duration product or left ventricular mass index. In the multiple linear regression analysis, after adjusting for age, the association of glomerular filtration rate and intima-media thickness with ambulatory heart rate and its standard deviation was lost. According to the logistic regression analysis, the predictors of any target organ damage were age (OR = 1.034 and 1.033 and night/day systolic blood pressure ratio (OR = 1.425 and 1.512. Neither 24 HR nor 24 HRV reached statistical significance. Conclusions High ambulatory heart rate and its variability, but not clinical HR, are associated with decreased carotid intima-media thickness and a higher glomerular filtration rate, although this is lost after adjusting for age. Trial Registration ClinicalTrials.gov: NCT01325064

  18. Heart rate turbulence as a marker of myocardial electrical instability in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    V. A. Makarova

    2014-01-01

    Full Text Available Heart rate turbulence is a myocardial electrical instability marker used to stratify the risk of sudden cardiac death. Fifty children aged 7 to 17 years with hypertrophic cardiomyopathy were examined. The survey program included standard electrocardiography, Doppler echocardiography, and 24-hour Holter ECG monitoring. Heart rate turbulence parameters, such as turbulence onset and turbulence slope, were analyzed. According to turbulence onset greater than zero, heart rate turbulence impairment was identified in 5 of the 24 patients included in the survey. The abnormal turbulence slope values of less than 6 msec/RR were found in 3 patients. Both parameters were abnormal in 1 patient. Heart rate turbulence impairment was significantly more common in children with the non-obstructive form of hypertrophic cardiomyopathy than in those with its obstructive form (χ2=3,05; p=0,08. All the children with abnormal heart rhythm turbulence values had one or more major risk factors for sudden ca