WorldWideScience

Sample records for total external dose

  1. Personnel external dose monitoring system

    International Nuclear Information System (INIS)

    Zhao Hengyuan

    1989-01-01

    The status and trend of personnel external dose monitoring system are introduced briefly. Their characteristics, functions and TLD bedges of some commercially available automatic TLD system, including UD-710A (Matsushita, Japan), Harshaw-2271, 2276 (Harshaw, USA), Harshaw-8000 (Harshaw/Filtrol), Studsvik-1313 (Sweden) and Pitman-800 (UK) were depicted in detail. Finally, personnel dose management and record keeping system were presented and two examples were given

  2. Pocket total dose meter

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.

    1984-10-01

    Laboratory measurements have demonstrated that it is possible to simultaneously measure absorbed dose and dose equivalent using a single tissue equivalent proportional counter. Small, pocket sized instruments are being developed to determine dose equivalent as the worker is exposed to mixed field radiation. This paper describes the electronic circuitry and computer algorithms used to determine dose equivalent in these devices

  3. Total dose meter development

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1986-09-01

    This report describes an alarming ''pocket'' monitor/dosimeter, based on a tissue-equivalent proportional counter, that measure both neutron and gamma dose and determines dose equivalent for the mixed radiation field. This report details the operation of the device and provides information on: the necessity for a device to measure dose equivalent in mixed radiation fields; the mathematical theory required to determine dose equivalent from tissue equivalent proportional; the detailed electronic circuits required; the algorithms required in the microprocessor used to calculate dose equivalent; the features of the instrument; program accomplishments and future plans

  4. Muscle-invasive bladder cancer treated with external beam radiation: influence of total dose, overall treatment time, and treatment interruption on local control

    International Nuclear Information System (INIS)

    Moonen, L.; Voet, H. van der; Nijs, R. de; Horenblas, S.; Hart, A.A.M.; Bartelink, H.

    1998-01-01

    Purpose: To evaluate and eventually quantify a possible influence of tumor proliferation during the external radiation course on local control in muscle invasive bladder cancer. Methods and Materials: The influence of total dose, overall treatment time, and treatment interruption has retrospectively been analyzed in a series of 379 patients with nonmetastasized, muscle-invasive transitional cell carcinoma of the urinary bladder. All patients received external beam radiotherapy at the Netherlands Cancer Institute between 1977 and 1990. Total dose varied between 50 and 75 Gy with a mean of 60.5 Gy and a median of 60.4 Gy. Overall treatment time varied between 20 and 270 days with a mean of 49 days and a median of 41 days. Number of fractions varied between 17 and 36 with a mean of 27 and a median of 26. Two hundred and forty-four patients had a continuous radiation course, whereas 135 had an intended split course or an unintended treatment interruption. Median follow-up was 22 months for all patients and 82 months for the 30 patients still alive at last follow-up. A stepwise procedure using proportional hazard regression has been used to identify prognostic treatment factors with respect to local recurrence as sole first recurrence. Results: One hundred and thirty-six patients experienced a local recurrence and 120 of these occurred before regional or distant metastases. The actuarial local control rate was 40.3% at 5 years and 32.3% at 10 years. In a multivariate analysis total dose showed a significant association with local control (p 0.0039), however in a markedly nonlinear way. In fact only those patients treated with a dose below 57.5 Gy had a significant higher bladder relapse rate, whereas no difference in relapse rate was found among patients treated with doses above 57.5 Gy. This remained the case even after adjustment for overall treatment time and all significant tumor and patient characteristics. The Normalized Tumor Dose (NTD) (α/β = 10) and NTD (

  5. Total external dose equivalent and effective dose derived to the Piedmont population in the period 30 Apr 1986 - 22 Sep 1987

    International Nuclear Information System (INIS)

    Cortissone, C.; Giacomelli, R.; Spezzano, P.; Porzio, L.

    1988-01-01

    Some dosimetric evaluations concerning the population of the Piemonte Region, obtained after the measurements made following the Chernobyl accident, are reported. The individual effective mean dose equivalent derived from the exposure and intake in the period April 30, 1986 - September 22, 1987, is about 0.50 mSv

  6. Airborne and total gamma absorbed dose rates at Patiala - India

    International Nuclear Information System (INIS)

    Tesfaye, Tilahun; Sahota, H.S.; Singh, K.

    1999-01-01

    The external gamma absorbed dose rate due to gamma rays originating from gamma emitting aerosols in air, is compared with the total external gamma absorbed dose rate at the Physics Department of Punjabi University, Patiala. It has been found out that the contribution, to the total external gamma absorbed dose rate, of radionuclides on particulate matter suspended in air is about 20% of the overall gamma absorbed dose rate. (author)

  7. Assessment of external dose indoors in Lithuania

    International Nuclear Information System (INIS)

    Pilkyte, L.; Butkus, D.; Morkunas, G.

    2006-01-01

    The aim of this paper was an assessment of external exposure indoors and its dependence on construction materials and indoor radon concentrations in Lithuanian living houses. Relationship of absorbed dose rate in air indoors and activity indexes of the most commonly used construction materials (wood, concrete and bricks) have been studied using results received in measurements done in >4700 rooms in 1995-2005. Possible connections of dose rate indoors with indoor radon concentrations are also discussed. Findings of this study helped to make an assessment of the mean value of effective dose of Lithuanian population due to external exposure indoors which is equal to 0.58 mSv y -1 . The received data might also be used in improvement of quality of personal dosimetric measurements done in premises constructed of different construction materials. (authors)

  8. 10 CFR 835.203 - Combining internal and external equivalent doses.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Combining internal and external equivalent doses. 835.203 Section 835.203 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.203 Combining internal and external equivalent doses. (a) The total effective dose...

  9. Correct statistical evaluation for total dose in rural settlement

    International Nuclear Information System (INIS)

    Vlasova, N.G.; Skryabin, A.M.

    2001-01-01

    Statistical evaluation of dose reduced to the determination of an average value and its error. If an average value of a total dose in general can be determined by simple summarizing of the averages of its external and internal components, the evaluation of an error can be received only from its distribution. Herewith, considering that both components of the dose are interdependent, to summarize their distributions, as a last ones of a random independent variables, is incorrect. It follows that an evaluation of the parameters of the total dose distribution, including an error, in general, cannot be received empirically, particularly, at the lack or absence of the data on one of the components of the last one, that constantly is happens in practice. If the evaluation of an average for total dose was defined somehow, as the best, as an average of a distribution of the values of individual total doses, as summarizing the individual external and internal doses by the random type, that an error of evaluation had not been produced. The methodical approach to evaluation of the total dose distribution at the lack of dosimetric information was designed. The essence of it is original way of an interpolation of an external dose distribution, using data on an internal dose

  10. External dose conversion factor from canal water

    International Nuclear Information System (INIS)

    Bhargava, Pradeep; Chitra, S.; Mhatre, Arti S.; Singh, Kapil Deo

    2016-01-01

    External dose needs to be estimated for the radioactivity discharged into the canal, as it constitutes one of the pathways of exposure to the public. Two activities are considered here: i) a walk along the bank of the canal ii) and the walk on the bridge. A concentration of 1 Bq/l is assumed here for the gross beta activity for the estimation of the dose conversion factor. A canal of width 14.39 m and the depth of 2.5 m is considered for this study. Length of the canal is taken to be infinite. Canal side wall is assumed to be the 25 cm thick concrete. Two points are selected, one on the bank, and the second on a bridge 1 m above the top surface of canal water. Dose Conversion factors for the person moving on the Bridge (at one meter above the water surface) and standing on bank of canal is estimated by using the QAD CG code for 137 Cs. Dose conversion factors for the location mentioned above are found to be 1.11E-10 Sv/hr/(Bq/l) and 1.55 E-11 Sv/hr/(Bq/l) for bridge and bank of canal respectively. (author)

  11. Reproductive function of animals exposed to low-dose external γ-radiation

    International Nuclear Information System (INIS)

    Izhevskij, P.V.; Krupitskaya, L.I.; Startsev, N.V.

    1993-01-01

    Chronic external γ-radiation effects on the reproductive function were simulated in male rats at doses equivalent to the dose obtained by the persons who participated in the liquidation of the Chernobyl poer plant accident aftereffects and by the population. The incidence of the pre-and postimplantation deaths was found increased in the progeny of males exposed to chronic external γ-irradiation at total doses of 158 and 237 Gy, though no strict dose dependence was observed

  12. WRAITH, Internal and External Doses from Atmospheric Release of Isotopes

    International Nuclear Information System (INIS)

    1984-01-01

    1 - Description of problem or function: WRAITH calculates the atmospheric transport of radioactive material to each of a number of downwind receptor points and the external and internal doses to a reference man at each of the receptor points. 2 - Method of solution: The movement of the released material through the atmosphere is calculated using a bivariate straight-line Gaussian distribution model with Pasquill values for standard deviations. The quantity of material in the released cloud is modified during its transit time to account for radioactive decay and daughter production. External doses due to exposure to the cloud can be calculated using a semi-infinite cloud approximation or a 'finite plume' three-dimensional point-kernel numerical integration technique. Internal doses due to acute inhalation are calculated using the ICRP Task Group Model and a four-segmented gastro- intestinal tract model. Translocation of the material between body compartments and retention in the body compartments are calculated using multiple exponential retention functions. Internal doses to each organ are calculated as sums of cross-organ doses with each target organ irradiated by radioactive material in a number of source organs. All doses are calculated in rads with separate values determined for high-LET and low-LET radiation. 3 - Restrictions on the complexity of the problem: - Doses to only three target organs (total body, red bone marrow, and the lungs) are considered and acute inhalation is the only pathway for material to enter the body. The dose response model is not valid for high-LET radiation other than alphas. The high-LET calculation ignores the contributions of neutrons, spontaneous fission fragments, and alpha recoil nuclei

  13. Effective dose equivalents from external radiation due to Chernobyl accident

    International Nuclear Information System (INIS)

    Erkin, V.G.; Debedev, O.V.; Balonov, M.I.; Parkhomenko, V.I.

    1992-01-01

    Summarized data on measurements of individual dose of external γ-sources in 1987-1990 of population of western areas of Bryansk region were presented. Type of distribution of effective dose equivalent, its significance for various professional and social groups of population depending on the type of the house was discussed. Dependences connecting surface soil activity in the populated locality with average dose of external radiation sources were presented. Tendency of dose variation in 1987-1990 was shown

  14. External doses from radioactive fallout. Dosimetry and levels

    International Nuclear Information System (INIS)

    Woehni, T.

    1995-01-01

    The design, manufacture and calibration of a TL-based dosemeter for measurement of low level external photon radiation are presented. The dosemeter is based on CaF 2 with 2 mm brass filter for energy compensation. It is able to resolve a 8% dose increase relative to natural background radiation. With this dosemeter external dose measurements were made in 6 villages in a heavily contaminated region in Russia (Chernobyl fallout), in order to assess external doses to the population. The results were analyzed in the light of additional existing information on radioactive deposition, social habits, decontamination measures and other influencing technical and physical factors. The observed dose values were lower than theoretical estimates of external doses based on published values for external dose levels relative to the level of contamination. 84 refs., 7 figs., 5 tabs

  15. External doses from radioactive fallout. Dosimetry and levels

    Energy Technology Data Exchange (ETDEWEB)

    Woehni, T

    1996-12-31

    The design, manufacture and calibration of a TL-based dosemeter for measurement of low level external photon radiation are presented. The dosemeter is based on CaF{sub 2} with 2 mm brass filter for energy compensation. It is able to resolve a 8% dose increase relative to natural background radiation. With this dosemeter external dose measurements were made in 6 villages in a heavily contaminated region in Russia (Chernobyl fallout), in order to assess external doses to the population. The results were analyzed in the light of additional existing information on radioactive deposition, social habits, decontamination measures and other influencing technical and physical factors. The observed dose values were lower than theoretical estimates of external doses based on published values for external dose levels relative to the level of contamination. 84 refs., 7 figs., 5 tabs.

  16. External doses from radioactive fallout. Dosimetry and levels

    Energy Technology Data Exchange (ETDEWEB)

    Woehni, T.

    1995-12-31

    The design, manufacture and calibration of a TL-based dosemeter for measurement of low level external photon radiation are presented. The dosemeter is based on CaF{sub 2} with 2 mm brass filter for energy compensation. It is able to resolve a 8% dose increase relative to natural background radiation. With this dosemeter external dose measurements were made in 6 villages in a heavily contaminated region in Russia (Chernobyl fallout), in order to assess external doses to the population. The results were analyzed in the light of additional existing information on radioactive deposition, social habits, decontamination measures and other influencing technical and physical factors. The observed dose values were lower than theoretical estimates of external doses based on published values for external dose levels relative to the level of contamination. 84 refs., 7 figs., 5 tabs.

  17. External doses of residents near semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Takada, Jun; Hoshi, Masaharu; Nagatomo, Tsuneto

    1999-01-01

    Accumulated external radiation doses of residents near the Semipalatinsk nuclear test site of the former USSR are presented as a results of study by the thermoluminescence technique for bricks sampled at several settlements in 1995 and 1996. The external doses that we evaluated from exposed bricks were up to about 100 cGy for resident. The external doses at several points in the center of Semipalatinsk City ranged from a background level to 60 cGy, which was remarkably high compared with the previously reported values based on military data. (author)

  18. p-MOSFET total dose dosimeter

    Science.gov (United States)

    Buehler, Martin G. (Inventor); Blaes, Brent R. (Inventor)

    1994-01-01

    A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

  19. Nuclear medicine external individual occupational doses in Rio de Janeiro

    International Nuclear Information System (INIS)

    Mauricio, Claudia L.P.; Lima, Ana Luiza S.; Silva, Herica L.R. da; Santos, Denison Souza; Silva, Claudio Ribeiro da

    2009-01-01

    According to the Brazilian National Database there are about 300 Nuclear Medicine Services (NMS) in Brazil, 44 of them located in the State of Rio de Janeiro (RJ). Individual dose measurements are an important input for the evaluation of occupational exposure in order to demonstrate the effectiveness of radioprotection implementation and to keep individual doses as low as possible. In Brazil, most nuclear medicine (NM) staff is routinely monitored for external dose. The internal committed dose is estimated only in abnormal conditions. This paper makes a statistics analysis of all the RJ NMS annual external occupational doses in year 2005. A study of the evolution of monthly external individual doses higher than 4.00 mSv from 2004 to 2008 is also presented. The number of registered thorax monthly dose higher than 4.0 mSv is increasing, as its value. In this period the highest dose measured reaches 56.9 mSv, in one month, in 2008. About 50% of the annual doses are smaller than the monthly record level of 0.20 mSv. In 2005, around 100 professionals of RJ NMS received annual doses higher than 4.0 mSv, considering only external doses, but no one receives doses higher than 20.0 mSv. Extremities dosimeters are used by about 15% of the staff. In some cases, these doses are more than 10 times higher than the dose in thorax. This study shows the importance to improve radiation protection procedures in NM. (author)

  20. Natural external radiation level and population dose in Hunan province

    International Nuclear Information System (INIS)

    1985-01-01

    A survey of the natural external radiation level in Hunan Province is reported. The measurements were performed with FD-71 scintillation radiometers. On the basis of measurements at about 1,600 locations, the contribution from cosmic radiation is found to be 3.0 x 10 -8 Gy.h -1 , and the average absorbed dose rates in air from terrestrial γ-radiation for outdoors, indoors and roads are determined to be 9.2, 13.1 and 9.0 x 10 -8 Gy.h -1 , respectively. The γ-radiation indoors is markedly higher than that outdoors by a factor of 1.42. The lowest γ-radiation level is found in the sedimentary plain around Donting Lake, while the highest absorbed dose rates in air from terrestrial radiation are observed in some areas with exposed granites. The indoor γ-radiation in brick houses is markedly higher than that in wooden houses. Tarred roads have evidently lower radiation level than sand-gravel roads or concrete roads. The annual effective dose equivalents to the population from cosmic and terrestrial sources are 0.256 and 0.756 mSv, respectively, with a total value of 1.012 mSv

  1. Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose

    Directory of Open Access Journals (Sweden)

    I. P. Stamat

    2016-01-01

    Full Text Available This paper provides review of equipment and methodology for measurement of photon radiation dose; analysis of possible reasons for considerable deviation between the Russian Federation population annual effective external irradiation doses and the relevant average global value. Data on Rospotrebnadzor bodies dosimetry equipment used for measurement of gamma radiation dose are collected and systematized. Over 60 kinds of dosimeters are used for monitoring of population external irradiation doses. Most of dosimeters used in the country have gas-discharge detectors (Geiger-Mueller counters, minor biochemical annunciators, etc. which have higher total values of own background level and of space radiation response than the modern dosimeters with scintillation detectors. This feature of dosimeters is apparently one of most plausible reasons of a bit overstating assessment of population external irradiation doses. The options for specification of population external irradiation doses assessment are: correction of gamma radiation dose measurement results with consideration of dosimeters own background level and space radiation response, introduction of more up-to-date dosimeters with scintillation detectors, etc. The most promising direction of research in verification of population external irradiation doses assessment is account of dosimetry equipment.

  2. Estimation of effective dose to public from external exposure to natural background radiation in saudi arabia

    International Nuclear Information System (INIS)

    Khalid, A. A.

    2003-01-01

    The effective dose values in sixteen cities in Saudi Arabia due to external exposure to natural radiation were evaluated. These doses are based on natural background components including external exposure to terrestrial radiation and cosmic rays. The importance of evaluating the effective dose to the public due to external exposure to natural background radiation lies in its epidemiological and dosimetric importance and in forming a basis for the assessment of the level of radioactive contamination or pollution in the environment in the future. The exposure to terrestrial radiation was measured using thermoluminescent dosimeters (TLD). The exposure from cosmic radiation was determined using empirical correlation. The values evaluated for the total annual effective dose in all cities were within the world average values. The highest total annual effective dose measured in Al-Khamis city was 802 μSv/y, as compared to 305 μSv/y in Dammam city, which was considered the lowest value

  3. The assessment of personal dose due to external radiation

    International Nuclear Information System (INIS)

    Boas, J.F.; Young, J.G.

    1990-01-01

    The fundamental basis of thermoluminescent dosimetry (TLD) is discussed and a number of considerations in the measurement of thermoluminescence described, with particular reference to CaSO 4 :Dy. The steps taken to convert a thermoluminescence measurement to an exposure and then an absorbed dose are outlined. The calculation of effective dose equivalents due to external exposure to γ-radiation in a number of situations commonly encountered in a uranium mine is discussed. Factors which may affect the accuracy of external dose assessments are described

  4. Analysis of records of external occupational dose records in Brazil

    International Nuclear Information System (INIS)

    Mauricio, Claudia L.P.; Silva, Herica L.R. da; Silva, Claudio Ribeiro da

    2014-01-01

    Brazil, a continental country, with actually more than 150,000 workers under individual monitoring for ionizing radiation, has implemented in 1987 a centralized system for storage of external occupational dose. This database has been improved over the years and is now a web-based information system called Brazilian External Occupational Dose Management Database System - GDOSE. This paper presents an overview of the Brazilian external occupational dose over the years. The estimated annual average effective dose shows a decrease from 2.4 mSv in 1987 to about 0.6 mSv, having been a marked reduction from 1987 to 1990. Analyzing by type of controlled practice, one sees that the medical and dental radiology is the area with the largest number of users of individual monitors (70%); followed by education practices (8%) and the industrial radiography (7%). Additionally to photon whole body monitoring; neutron monitors are used in maintenance (36%), reactor (30%) and education (27%); and extremity monitors, in education (27%), nuclear medicine (22%) and radiology (19%). In terms of collective dose, the highest values are also found in conventional radiology, but the highest average dose values are those of interventional radiology. Nuclear medicine, R and D and radiotherapy also have average annual effective dose higher than 1 mSv. However, there is some very high dose values registered in GDOSE that give false information. This should be better analyzed in the future. Annual doses above 500 are certainly not realistic. (author)

  5. External dose assessment in the Ukraine following the Chernobyl accident

    Science.gov (United States)

    Frazier, Remi Jordan Lesartre

    While the physiological effects of radiation exposure have been well characterized in general, it remains unclear what the relationship is between large-scale radiological events and psychosocial behavior outcomes in individuals or populations. To investigate this, the National Science Foundation funded a research project in 2008 at the University of Colorado in collaboration with Colorado State University to expand the knowledge of complex interactions between radiation exposure, perception of risk, and psychosocial behavior outcomes by modeling outcomes for a representative sample of the population of the Ukraine which had been exposed to radiocontaminant materials released by the reactor accident at Chernobyl on 26 April 1986. In service of this project, a methodology (based substantially on previously published models specific to the Chernobyl disaster and the Ukrainian population) was developed for daily cumulative effective external dose and dose rate assessment for individuals in the Ukraine for as a result of the Chernobyl disaster. A software platform was designed and produced to estimate effective external dose and dose rate for individuals based on their age, occupation, and location of residence on each day between 26 April 1986 and 31 December 2009. A methodology was developed to transform published 137Cs soil deposition contour maps from the Comprehensive Atlas of Caesium Deposition on Europe after the Chernobyl Accident into a geospatial database to access these data as a radiological source term. Cumulative effective external dose and dose rate were computed for each individual in a 703-member cohort of Ukrainians randomly selected to be representative of the population of the country as a whole. Error was estimated for the resulting individual dose and dose rate values with Monte Carlo simulations. Distributions of input parameters for the dose assessment methodology were compared to computed dose and dose rate estimates to determine which

  6. Dose estimation in embryo or fetus in external fields

    International Nuclear Information System (INIS)

    Gregori, Beatriz N.

    2001-01-01

    The embryo or the fetus can be irradiated as result of radiological procedures of diagnosis of therapy in where the beam effects directly on the same one or in tissues or peripherical organs. Some authors have suggested that in the first stages of the pregnancy the dose in ovaries can be the good estimated of the dose in embryo or fetus. In advanced conditions of the development, probably also in the early stage, is more appropriated to specify the dose in the embryo or fetus equal of the uterus. The dose in the uterus is a good estimated so much for external irradiation as for radionuclides incorporation

  7. Dose Record Analysis of External Exposure of Workers in Madagascar

    International Nuclear Information System (INIS)

    Andriambololona, R.; Ratovonjanahary, J. F.; Randriantsizafy, R. D.

    2004-01-01

    External personnel monitoring of workers in diagnostic radiology in Madagascar using thermoluminescence techniques has been studied in previous work for the period of 1990 to 2000. The study was based on the average of Hp(0.07) and Hp(10) and on the annual dose distribution. The results showed that mean doses are very low compared with the annual dose limits for workers of 20 mSv per year and are comparable with natural contribution of telluric X and gamma exposure which is evaluated as 3.21 mSv per year in Antananarivo. No trend in the average was observed, however, the last 4 years, the results showed a substantial decrease in the average from 2 mSv to 1 mSv. It was assumed that this was the impact of the implementation by radiation staff in their workplace of the in force regulation which is in compliance with the new basic safety standards. Indeed, since 1996, Madagascar-Institut National des Sciences et Techniques Nucleaires (Madagascar-INSTN) and the Association Nationale de Radioprotection de Madagascar (ANARAPMAD), the Madagascar radiation protection society and associate member of IRPA, set up a national program for training of radiation workers. The number of workers trained during this period is evaluated as 50% of the total number of radiation workers in Madagascar. The present work is a continuation of the above mentioned survey during the period of 2001 to 2003. The training program was upgraded to involve personnel who will be in charge of radiation protection and safety in workplace and the training cycle lasts 2 years instead of 3 days in the previous program. The survey has been extended to include all radiation workers in Madagascar though the medical field is still the main application and represents more than 90 percent of the latter. The results shows that for this last 3 years, an other substantial decrease from 1 mSv to 0.5 mSv was observed in the average. In the dose distribution, more than 98 percent of the Hp(0.07) and more than 99

  8. Probabilistic approach to external cloud dose calculations using onsite meteorological data

    International Nuclear Information System (INIS)

    Strenge, D.L.; Watson, E.C.; Bander, T.J.; Kennedy, W.E.

    1976-01-01

    A method is described for calculation of external total body and skin doses from accidental atmospheric releases of radionuclides based on hourly onsite meteorological data. The method involves calculation of dose values from a finite size cloud for each hourly observation for a given radionuclide inventory. These values are then used to determine the probability of occurrence of dose levels for specified release times ranging from one hour to 30 days

  9. Dose-rate effects in external beam radiotherapy redux

    International Nuclear Information System (INIS)

    Ling, C. Clifton; Gerweck, Leo E.; Zaider, Marco; Yorke, Ellen

    2010-01-01

    Recent developments in external beam radiotherapy, both in technical advances and in clinical approaches, have prompted renewed discussions on the potential influence of dose-rate on radio-response in certain treatment scenarios. We consider the multiple factors that influence the dose-rate effect, e.g. radical recombination, the kinetics of sublethal damage repair for tumors and normal tissues, the difference in α/β ratio for early and late reacting tissues, and perform a comprehensive literature review. Based on radiobiological considerations and the linear-quadratic (LQ) model we estimate the influence of overall treatment time on radio-response for specific clinical situations. As the influence of dose-rate applies to both the tumor and normal tissues, in oligo-fractionated treatment using large doses per fraction, the influence of delivery prolongation is likely important, with late reacting normal tissues being generally more sensitive to the dose-rate effect than tumors and early reacting tissues. In conventional fractionated treatment using 1.8-2 Gy per fraction and treatment times of 2-10 min, the influence of dose-rate is relatively small. Lastly, the dose-rate effect in external beam radiotherapy is governed by the overall beam-on-time, not by the average linac dose-rate, nor by the instantaneous dose-rate within individual linac pulses which could be as high as 3 x 10 6 MU/min.

  10. Methods of assessing total doses integrated across pathways

    International Nuclear Information System (INIS)

    Grzechnik, M.; Camplin, W.; Clyne, F.; Allott, R.; Webbe-Wood, D.

    2006-01-01

    Calculated doses for comparison with limits resulting from discharges into the environment should be summed across all relevant pathways and food groups to ensure adequate protection. Current methodology for assessments used in the radioactivity in Food and the Environment (R.I.F.E.) reports separate doses from pathways related to liquid discharges of radioactivity to the environment from those due to gaseous releases. Surveys of local inhabitant food consumption and occupancy rates are conducted in the vicinity of nuclear sites. Information has been recorded in an integrated way, such that the data for each individual is recorded for all pathways of interest. These can include consumption of foods, such as fish, crustaceans, molluscs, fruit and vegetables, milk and meats. Occupancy times over beach sediments and time spent in close proximity to the site is also recorded for inclusion of external and inhalation radiation dose pathways. The integrated habits survey data may be combined with monitored environmental radionuclide concentrations to calculate total dose. The criteria for successful adoption of a method for this calculation were: Reproducibility can others easily use the approach and reassess doses? Rigour and realism how good is the match with reality?Transparency a measure of the ease with which others can understand how the calculations are performed and what they mean. Homogeneity is the group receiving the dose relatively homogeneous with respect to age, diet and those aspects that affect the dose received? Five methods of total dose calculation were compared and ranked according to their suitability. Each method was labelled (A to E) and given a short, relevant name for identification. The methods are described below; A) Individual doses to individuals are calculated and critical group selection is dependent on dose received. B) Individual Plus As in A, but consumption and occupancy rates for high dose is used to derive rates for application in

  11. External dose-rate conversion factors for calculation of dose to the public

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    This report presents a tabulation of dose-rate conversion factors for external exposure to photons and electrons emitted by radionuclides in the environment. This report was prepared in conjunction with criteria for limiting dose equivalents to members of the public from operations of the US Department of Energy (DOE). The dose-rate conversion factors are provided for use by the DOE and its contractors in performing calculations of external dose equivalents to members of the public. The dose-rate conversion factors for external exposure to photons and electrons presented in this report are based on a methodology developed at Oak Ridge National Laboratory. However, some adjustments of the previously documented methodology have been made in obtaining the dose-rate conversion factors in this report. 42 refs., 1 fig., 4 tabs.

  12. Theoretic simulation for CMOS device on total dose radiation response

    International Nuclear Information System (INIS)

    He Baoping; Zhou Heqin; Guo Hongxia; He Chaohui; Zhou Hui; Luo Yinhong; Zhang Fengqi

    2006-01-01

    Total dose effect is simulated for C4007B, CC4007RH and CC4011 devices at different absorbed dose rate by using linear system theory. When irradiation response and dose are linear, total dose radiation and post-irradiation annealing at room temperature are determined for one random by choosing absorbed dose rate, and total dose effect at other absorbed dose rate can be predicted by using linear system theory. The simulating results agree with the experimental results at different absorbed dose rate. (authors)

  13. External dose reconstruction in tooth enamel of Techa riverside residents

    Energy Technology Data Exchange (ETDEWEB)

    Shishkina, E.A.; Volchkova, A.Yu.; Krivoschapov, V.A.; Degteva, M.O. [Urals Research Center for Radiation Medicine, Chelyabinsk (Russian Federation); Timofeev, Y.S.; Zalyapin, V.I. [Southern Urals State University, Chelyabinsk (Russian Federation); Fattibene, P.; Della Monaca, S.; De Coste, V. [Istituto Superiore di Sanita e Istituto Nazionale di Fisica Nucleare, Rome (Italy); Wieser, A. [Helmholtz Zentrum Muenchen, German Research Centre for Environmental Health, Neuherberg (Germany); Ivanov, D.V. [M.N. Mikheev Institute of Metal Physics, Ural Division of the Russian Academy of Sciences, Ekaterinburg (Russian Federation); Ural Federal University, Yekaterinburg (Russian Federation); Anspaugh, L.R. [University of Utah, Salt Lake City, UT (United States)

    2016-11-15

    This study summarizes the 20-year efforts for dose reconstruction in tooth enamel of the Techa riverside residents exposed to ionizing radiation as a result of radionuclide releases into the river in 1949-1956. It represents the first combined analysis of all the data available on EPR dosimetry with teeth of permanent residents of the Techa riverside territory. Results of electron paramagnetic resonance (EPR) measurements of 302 teeth donated by 173 individuals living permanently in Techa riverside settlements over the period of 1950-1952 were analyzed. These people were residents of villages located at the free-flowing river stream or at the banks of stagnant reservoirs such as ponds or blind river forks. Cumulative absorbed doses measured using EPR are from several sources of exposure, viz., background radiation, internal exposure due to bone-seeking radionuclides ({sup 89}Sr, {sup 90}Sr/{sup 90}Y), internal exposure due to {sup 137}Cs/{sup 137m}Ba incorporated in soft tissues, and anthropogenic external exposure. The purpose of the present study was to evaluate the contribution of different sources of enamel exposure and to deduce external doses to be used for validation of the Techa River Dosimetry System (TRDS). Since various EPR methods were used, harmonization of these methods was critical. Overall, the mean cumulative background dose was found to be 63 ± 47 mGy; cumulative internal doses due to {sup 89}Sr and {sup 90}Sr/{sup 90}Y were within the range of 10-110 mGy; cumulative internal doses due to {sup 137}Cs/{sup 137m}Ba depend on the distance from the site of releases and varied from 1 mGy up to 90 mGy; mean external doses were maximum for settlements located at the banks of stagnant reservoirs (∝500 mGy); in contrast, external doses for settlements located along the free-flowing river stream did not exceed 160 mGy and decreased downstream with increasing distance from the site of release. External enamel doses calculated using the TRDS code and

  14. Salvage of infected total knee arthroplasty with Ilizarov external fixator

    Directory of Open Access Journals (Sweden)

    Venkata Gurava Reddy

    2011-01-01

    Full Text Available Background: Knee arthrodesis may be the only option of treatment in cases of chronic infected total knee arthroplasty (TKA with concomitant irreparable extensor mechanism disruption, extensive bone loss or severe systemic morbidities. Circular external fixation offers possible progressive adjustment to stimulate the bony fusion and to make corrections in alignment. We evaluated the results of knee arthrodesis with one or two stage circular external fixator for infected TKA. Materials and Methods: 16 cases of femoro-tibial fusion were retrospectively evaluated. Male-to-female ratio was 10:6. Mean age of the patients was 62.2 years. Cierney-Mader classification was used for anatomical and physiological evaluation while the bone stock deficiency was classified into mild, moderate and severe. Surgical technique involved either single or two stage arthrodesis using circular external fixator. Results: Union was achieved in 15 patients (93.75%. The mean duration for union (frame application time in these patients was 28.33 weeks (range 22 to 36 weeks. Analysis showed that in the group with frame application time of less than 28 weeks, the incidence of mild to moderate bone deficiency was 83.33%, while in the frame application time more than 28 weeks group the incidence was 20% (P-value 0.034. Similarly the incidence of Cierney-Mader 4B (Bl, Bs, Bls was found to be 33.33% in the group of frame application time of less than 28 weeks, while it was 90% in the group with frame application time more than 28 weeks (P-value 0.035. Conclusion: Circular external fixator is a safe and reliable method to achieve knee arthrodesis in cases of deep infection following TKA. Severe bone stock deficiency and Cierney- Mader type B host are likely risk factors for prolonged frame application time. We recommend a two-stage procedure especially when there is compromised host or severe bone loss.

  15. Dose evaluation for external exposure in radiation accidents

    International Nuclear Information System (INIS)

    Maruyama, Takashi

    1989-01-01

    Abnormal exposures including emergency and accidental are categorized into external exposure and internal contamination, although both of these may be associated with external contamination. From a point of view of lifesaving in the abnormal exposures, it is primarily important to evaluate radiation dose of exposed persons as soon as possible. This report reviews the status of early dosimetry in the accidental exposures and discusses the optimum methodology of the early dose determination for external exposures in abnormal exposures. Personal monitors generally give an indication of dose to an exposed person only at a single part of the body. The data obtained from the personal monitors should be interpreted with care and in the light of information about the circumstances of exposure. In most cases, the records of environmental monitors or the survey with area monitors provide valuable information on the radiation fields. In the some cases, the reconstruction of the abnormal exposure is required for the dose evaluation by means of phantom experiments. In the case of neutron exposures, activation products in the body or its components or personnel possession can be useful for the early dosimetry. If the dose received by the whole body is evaluated as being very high, clinical observations and biological investigations may be more important guide to initial medical treatment than the early dosimetry. For the dose evaluation of general public, depending on the size of abnormal exposure, information that could be valuable in the assessment of abnormal exposures will come from the early dose estimates with environmental monitors and radiation survey meters. (author)

  16. Determination of dose factors for external gamma radiation in dwellings

    International Nuclear Information System (INIS)

    Maduar, M.F.; Hiromoto, G.

    2000-01-01

    A significant contribution to the global population exposure to ionizing radiation arises from natural sources, especially from radionuclides present in terrestrial crust. Human activities can eventually increase that exposure to significant levels, from the point of view of radiological protection. The presence of natural radionuclides in building materials may lead to an increment of both external and internal radiation exposure of the population. External exposure in dwellings arises from gamma-emitter radionuclides existing in the walls, floor and ceiling of their rooms. Mathematical models can be used to predict external dose rates inside the room, known the radionuclide concentration activities in dwelling constituents. This paper presents a methodology for theoretical evaluation of external gamma doses due to radionuclides present in the walls of an hypothetical standard room. The room is modeled as three pairs of rectangular sheets with finite thickness. Assessment of doses was performed through the application of photon transport model, taking in account self-absorption and radiation buildup. As the external dose due to a particular radionuclide is proportional to its activity concentration, results are presented as dose factors, defined as a ratio of absorbed dose (nGy.h -1 ) to the activity concentration (Bq.kg -1 ), for each radionuclide. The radionuclides were assumed to be uniformly distributed in the building materials. Calculations were performed for concrete walls and results are presented for 40 K, 226 Ra, and 232 Th, taking in account, for dose calculations, all gamma emitters from 226 Ra and 232 Th decay chains. Sensitivity of the model was estimated by varying four of its input parameters within a reasonable range of applicability, while leaving all other parameters at fixed selected values. The parameters studied and respective ranges of variation were: for thickness, 5 to 60 cm; for density, 0.5 to 4 g.cm -3 ; for the room length, 1.5 to 10 m

  17. Calculation of dose conversion factors for doses in the fingernails to organ doses at external gamma irradiation in air

    International Nuclear Information System (INIS)

    Khailov, A.M.; Ivannikov, A.I.; Skvortsov, V.G.; Stepanenko, V.F.; Orlenko, S.P.; Flood, A.B.; Williams, B.B.; Swartz, H.M.

    2015-01-01

    Absorbed doses to fingernails and organs were calculated for a set of homogenous external gamma-ray irradiation geometries in air. The doses were obtained by stochastic modeling of the ionizing particle transport (Monte Carlo method) for a mathematical human phantom with arms and hands placed loosely along the sides of the body. The resulting dose conversion factors for absorbed doses in fingernails can be used to assess the dose distribution and magnitude in practical dose reconstruction problems. For purposes of estimating dose in a large population exposed to radiation in order to triage people for treatment of acute radiation syndrome, the calculated data for a range of energies having a width of from 0.05 to 3.5 MeV were used to convert absorbed doses in fingernails to corresponding doses in organs and the whole body as well as the effective dose. Doses were assessed based on assumed rates of radioactive fallout at different time periods following a nuclear explosion. - Highlights: • Elemental composition and density of nails were determined. • MIRD-type mathematical human phantom with arms and hands was created. • Organ doses and doses to nails were calculated for external photon exposure in air. • Effective dose and nail doses values are close for rotational and soil surface exposures.

  18. Age-dependent conversion coefficients for organ doses and effective doses for external neutron irradiation

    International Nuclear Information System (INIS)

    Nishizaki, Chihiro; Endo, Akira; Takahashi, Fumiaki

    2006-06-01

    To utilize dose assessment of the public for external neutron irradiation, conversion coefficients of absorbed doses of organs and effective doses were calculated using the numerical simulation technique for six different ages (adult, 15, 10, 5 and 1 years and newborn), which represent the member of the public. Calculations were performed using six age-specific anthropomorphic phantoms and a Monte Carlo radiation transport code for two irradiation geometries, anterior-posterior and rotational geometries, for 20 incident energies from thermal to 20 MeV. Effective doses defined by the 1990 Recommendation of ICRP were calculated from the absorbed doses in 21 organs. The calculated results were tabulated in the form of absorbed doses and effective doses per unit neutron fluence. The calculated conversion coefficients are used for dose assessment of the public around nuclear facilities and accelerator facilities. (author)

  19. External dose estimates for future Bikini Atoll inhabitants

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Crites, T.R.; Robison, W.L.

    1976-01-01

    To evaluate the potential radiation doses that may be received by the returning Bikinians, we surveyed the residual radioactivity on Bikini and Eneu Islands in June of 1975. An integral part of the survey included measurements of gamma-ray exposure rates which are used to estimate external gamma-ray doses. The survey showed that on Bikini Island the rates are highly variable: values near the shores are generally of the order of 10 to 20 μR/h, while those within the interior average about 40 μR/h with a range of roughly 30 to 100 μR/h. Eneu Island, however, is characterized by more or less uniformly distributed gamma radiation levels of less than 10 μR/h over the entire island. These data, in conjunction with population statistics and expected life styles, allowed us to estimate the potential external gamma-ray doses associated with proposed housing locations along the lagoon road and within the interior portions of Bikini Island as well as along the lagoon side of Eneu Island. As expected, living on Eneu Island results in the lowest doses: 0.12 rem during the first year and 2.9 rem during 30 years. The highest values, 0.28 rem during the first year and 5.9 rem over 30 years, may potentially be received by inhabitants living within the interior of Bikini Island. Other options under consideration produce intermediate values

  20. 10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.

    Science.gov (United States)

    2010-01-01

    ... external and internal doses. (a) If the licensee is required to monitor under both §§ 20.1502 (a) and (b), the licensee shall demonstrate compliance with the dose limits by summing external and internal doses... compliance with the requirements for summation of external and internal doses by meeting one of the...

  1. Indoor external dose rates due to decorative sheet stone

    Energy Technology Data Exchange (ETDEWEB)

    Lu, C.H.; Sheu, R.D.; Jiang, S.H. [Dept. of Engineering and System Science, National Tsing Hua Univ., Hsinchu (Taiwan)

    2002-03-01

    The specific activities in decorative sheet stone made of granite or marble were measured, whereby the absolute peak efficiency of the HPGe detectors employed in the measurements for the sheet-stone sample was determined using the semi-empirical method. The spatial distribution for the indoor external dose rates due to the radionuclides present in the decorative sheet stone used to clad the floor and the four walls of a standard room was calculated using a three-dimensional point kernel computer code. It was found that the spatial distribution for the indoor dose rates was complex and non-uniform, which represents a difference in relation to the results of earlier studies. (orig.)

  2. Indoor external dose rates due to decorative sheet stone

    International Nuclear Information System (INIS)

    Lu, C.H.; Sheu, R.D.; Jiang, S.H.

    2002-01-01

    The specific activities in decorative sheet stone made of granite or marble were measured, whereby the absolute peak efficiency of the HPGe detectors employed in the measurements for the sheet-stone sample was determined using the semi-empirical method. The spatial distribution for the indoor external dose rates due to the radionuclides present in the decorative sheet stone used to clad the floor and the four walls of a standard room was calculated using a three-dimensional point kernel computer code. It was found that the spatial distribution for the indoor dose rates was complex and non-uniform, which represents a difference in relation to the results of earlier studies. (orig.)

  3. Parallel processing of dose calculation for external photon beam therapy

    International Nuclear Information System (INIS)

    Kunieda, Etsuo; Ando, Yutaka; Tsukamoto, Nobuhiro; Ito, Hisao; Kubo, Atsushi

    1994-01-01

    We implemented external photon beam dose calculation programs into a parallel processor system consisting of Transputers, 32-bit processors especially suitable for multi-processor configuration. Two network conformations, binary-tree and pipeline, were evaluated for rectangular and irregular field dose calculation algorithms. Although computation speed increased in proportion to the number of CPU, substantial overhead caused by inter-processor communication occurred when a smaller computation load was delivered to each processor. On the other hand, for irregular field calculation, which requires more computation capability for each calculation point, the communication overhead was still less even when more than 50 processors were involved. Real-time responses could be expected for more complex algorithms by increasing the number of processors. (author)

  4. External contamination and skin dose. From ICRP and regulations to skin dose evaluation in practice

    International Nuclear Information System (INIS)

    Le Coulteulx, I.; Apretna, D.; Beaugerie, M.; Fenolland, J.; Frey, R.; Gonin, M.; Landry, B.; Laporte, E.; Le Guen, B.; Leval, D.

    2006-01-01

    Dose limitation to the skin is an objective of radiation protection. Our aim is to propose in case of skin contamination in EDF NPPs a simply, quickly and reproducible procedure for evaluating skin dose. French regulation admit an annual limit for skin dose over one square centimeter equal to 500 mSv. ICRP Publication 26 and 60 recommend that dose assessment be performed only if skin dose might be equal to or more than 50 mSv at basal cells. To respect this recommendation, an alert value (A) must be determined. This value is the lowest value of measurement from which dose assessment has to be made, based on the hypothesis that uninterrupted work time in controlled area is no more than four hours. This alert value (A) has been established for three external detection equipments, and for the ten radionuclides commonly detected. In case of external contamination, a first measurement is performed. If the value exceeds value (A), other measurements are instituted because skin dose evaluation needs to know other parameters as: - the radioactivity of the most contaminated square centimeter of the skin, - the identity of the radionuclides and their relative proportion. At the same time, we have to evaluate the length of the exposure. At last, we use different compiled results in a program developed from excel software which allow to calculate automatically the skin dose. This work has allowed us to publish an occupational health guideline about the assessment of skin dose in case of external contamination in EDF NPPs and to create an information booklet for workers. The authors propose to examine used methodology and to demonstrate the software. (authors)

  5. Dose equivalent distributions in the AAEC total body nitrogen facility

    International Nuclear Information System (INIS)

    Allen, B.J.; Bailey, G.M.; McGregor, B.J.

    1985-01-01

    The incident neutron dose equivalent in the AAEC total body nitrogen facility is measured by a calibrated remmeter. Dose equivalent rates and distributions are calculated by Monte Carlo techniques which take account of the secondary neutron flux from the collimator. Experiment and calculation are found to be in satisfactory agreement. The effective dose equivalent per exposure is determined by weighting organ doses, and the potential detriment per exposure is calculated from ICRP risk factors

  6. Treatment of cervical carcinoma by total hysterectomy and postoperative external irradiation

    International Nuclear Information System (INIS)

    Papavasiliou, C.; Yiogarakis, D.; Pappas, J.; Keramopoulos, A.

    1980-01-01

    The survival rates of 36 patients with early cervical carcinoma who had undergone total hysterectomy and bilateral salpingoophorectomy (THBSO) were compared to the survival rates of 41 patients who were subjected to the radical operation. As an integral part of their therapy both groups postoperatively received adequate doses of external beam supervoltage irradiation. Satisfactory results were obtained in both groups of patients. According to these results THBSO followed by postoperative radiotherapy is adequate treatment for early cervical carcinoma. In comparison to the radical operation or curietherapy alone this type of treatment has the advantage of requiring less surgical or radiotherapeutic expertise; it probably is associated with less morbidity

  7. SUBDOSA: a computer program for calculating external doses from accidental atmospheric releases of radionuclides

    International Nuclear Information System (INIS)

    Strenge, D.L.; Watson, E.C.; Houston, J.R.

    1975-06-01

    A computer program, SUBDOSA, was developed for calculating external γ and β doses to individuals from the accidental release of radionuclides to the atmosphere. Characteristics of SUBDOSA are: doses from both γ and β radiation are calculated as a function of depth in tissue, summed and reported as skin, eye, gonadal, and total body dose; doses are calculated for releases within each of several release time intervals and nuclide inventories and atmospheric dispersion conditions are considered for each time interval; radioactive decay is considered during the release and/or transit using a chain decay scheme with branching to account for transitions to and from isomeric states; the dose from gamma radiation is calculated using a numerical integration technique to account for the finite size of the plume; and the program computes and lists the normalized air concentrations at ground level as a function of distance from the point of release. (auth)

  8. Evaluation of dose from external irradiation for individuals living in areas affected by the Fukushima Daiichi nuclear plant accident

    International Nuclear Information System (INIS)

    Naito, Wataru; Uesaka, Motoki; Yamada, Chie; Ishii, Hideki

    2015-01-01

    In order to effectively and appropriately manage external radiation doses in the affected areas of Fukushima, it is important to identify when, where and how much exposure occurred. It is also necessary to quantitatively measure external exposure and air dose rates for different activity patterns in individuals living and working in Japanese-style buildings. The authors used a new personal dosemeter (D-shuttle) along with a global positioning system and geographical information system to relate personal dose rate with activity patterns and air dose rate. Hourly individual doses obtained by D-shuttle can provide an effective communication tool for those who want to identify when and how much exposure occurs. Personal monitoring of 26 volunteers showed that personal doses obtained from D-shuttle were ∼30 % of cumulative air dose estimated by data from the airborne monitoring survey. This analysis showed that, for most study volunteers, the exposure from staying at home represented about half of the total cumulative dose. This suggests that even though the peak exposure doses may be observed outside of working hours, to develop appropriate countermeasures for external dose reduction, it is thus important to identify the contributions of individuals' time-activities. This study provides a valuable basis for developing a realistic and pragmatic method to estimate external doses of individuals in Fukushima. (authors)

  9. Studies of workers exposed to low doses of external radiation

    International Nuclear Information System (INIS)

    Gilbert, E.S.

    1991-04-01

    Currently, several epidemiologic studies of workers who have been exposed occupationally to low levels of radiation are being conducted, and include studies of workers in the United States, Great Britain, and Canada involved in the production of both defense materials and nuclear power. This paper focuses on studies that evaluate the possible adverse effects resulting from external exposure to radiation. The radiation risk estimates that have been used to establish radiation protection standards for workers and others have been obtained mainly from studies of persons exposed at high doses and dose rates. However, questions remain with regard to the extrapolation process that has been necessary for estimating low-level radiation risks. Occupational studies provide a direct assessment of risk based on data on persons exposed at the actual levels of interest. If current risk estimates are correct, these studies have very little chance of detecting risk, but can still be used to provide useful upper limits on risks. The studies are also adequate to detect serious underestimation of risks. 36 refs., 3 figs., 3 tabs

  10. Simulation experiment on total ionization dose effects of linear CCD

    International Nuclear Information System (INIS)

    Tang Benqi; Zhang Yong; Xiao Zhigang; Wang Zujun; Huang Shaoyan

    2004-01-01

    We carry out the ionization radiation experiment of linear CCDs operated in unbiased, biased, biased and driven mode respectively by Co-60 γ source with our self-designed test system, and offline test the Dark signal and Saturation voltage and SNR varied with total dose for TCD132D, and get some valuable results. On the basis of above work, we set forth a primary experiment approaches to simulate the total dose radiation effects of charge coupled devices. (authors)

  11. External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Kim, Jung In; Park, Jong Min; Park, Yang Kyun; Ye, Sung Joon [Medical Research Center, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cho, Kun Woo; Cho, Woon Kap [Radiation Research, Korean Institute of Nuclear Safety, Daejeon (Korea, Republic of); Lim, Chun Il [Korea Food and Drug Administration, Seoul (Korea, Republic of)

    2010-11-15

    We report the results of an external audit on the absorbed dose of radiotherapy beams independently performed by third parties. For this effort, we developed a method to measure the absorbed dose to water in an easy and convenient setup of solid water phantom. In 2008, 12 radiotherapy centers voluntarily participated in the external auditing program and 47 beams of X-ray and electron were independently calibrated by the third party's American Association of Physicists in Medicine (AAPM) task group (TG)-51 protocol. Even though the AAPM TG-51 protocol recommended the use of water, water as a phantom has a few disadvantages, especially in a busy clinic. Instead, we used solid water phantom due to its reproducibility and convenience in terms of setup and transport. Dose conversion factors between solid water and water were determined for photon and electron beams of various energies by using a scaling method and experimental measurements. Most of the beams (74%) were within {+-}2% of the deviation from the third party's protocol. However, two of 20 X-ray beams and three of 27 electron beams were out of the tolerance ({+-}3%), including two beams with a >10% deviation. X-ray beams of higher than 6 MV had no conversion factors, while a 6 MV absorbed dose to a solid water phantom was 0.4% less than the dose to water. The electron dose conversion factors between the solid water phantom and water were determined: The higher the electron energy, the less is the conversion factor. The total uncertainty of the TG-51 protocol measurement using a solid water phantom was determined to be {+-}1.5%. The developed method was successfully applied for the external auditing program, which could be evolved into a credential program of multi-institutional clinical trials. This dosimetry saved time for measuring doses as well as decreased the uncertainty of measurement possibly resulting from the reference setup in water.

  12. Dependence of total dose response of bipolar linear microcircuits on applied dose rate

    International Nuclear Information System (INIS)

    McClure, S.; Will, W.; Perry, G.; Pease, R.L.

    1994-01-01

    The effect of dose rate on the total dose radiation hardness of three commercial bipolar linear microcircuits is investigated. Total dose tests of linear bipolar microcircuits show larger degradation at 0.167 rad/s than at 90 rad/s even after the high dose rate test is followed by a room temperature plus a 100 C anneal. No systematic correlation could be found for degradation at low dose rate versus high dose rate and anneal. Comparison of the low dose rate with the high dose rate anneal data indicates that MIL-STD-883, method 1019.4 is not a worst-case test method when applied to bipolar microcircuits for low dose rate space applications

  13. Increasing Use of Dose-Escalated External Beam Radiation Therapy for Men With Nonmetastatic Prostate Cancer

    International Nuclear Information System (INIS)

    Swisher-McClure, Samuel; Mitra, Nandita; Woo, Kaitlin; Smaldone, Marc; Uzzo, Robert; Bekelman, Justin E.

    2014-01-01

    Purpose: To examine recent practice patterns, using a large national cancer registry, to understand the extent to which dose-escalated external beam radiation therapy (EBRT) has been incorporated into routine clinical practice for men with prostate cancer. Methods and Materials: We conducted a retrospective observational cohort study using the National Cancer Data Base, a nationwide oncology outcomes database in the United States. We identified 98,755 men diagnosed with nonmetastatic prostate cancer between 2006 and 2011 who received definitive EBRT and classified patients into National Comprehensive Cancer Network (NCCN) risk groups. We defined dose-escalated EBRT as total prescribed dose of ≥75.6 Gy. Using multivariable logistic regression, we examined the association of patient, clinical, and demographic characteristics with the use of dose-escalated EBRT. Results: Overall, 81.6% of men received dose-escalated EBRT during the study period. The use of dose-escalated EBRT did not vary substantially by NCCN risk group. Use of dose-escalated EBRT increased from 70.7% of patients receiving treatment in 2006 to 89.8% of patients receiving treatment in 2011. On multivariable analysis, year of diagnosis and use of intensity modulated radiation therapy were significantly associated with receipt of dose-escalated EBRT. Conclusions: Our study results indicate that dose-escalated EBRT has been widely adopted by radiation oncologists treating prostate cancer in the United States. The proportion of patients receiving dose-escalated EBRT increased nearly 20% between 2006 and 2011. We observed high utilization rates of dose-escalated EBRT within all disease risk groups. Adoption of intensity modulated radiation therapy was strongly associated with use of dose-escalated treatment

  14. Radiation optic neuropathy after megavoltage external-beam irradiation: Analysis of time-dose factors

    International Nuclear Information System (INIS)

    Parsons, J.T.; Bova, F.J.; Million, R.R.

    1994-01-01

    To investigate the risk of radiation-induced optic neuropathy according to total radiotherapy dose and fraction size, based on both retrospective and prospectively collected data. Between October 1964 and May 1989, 215 optic nerves in 131 patients received fractionated external-beam irradiation during the treatment of primary extracranial head and neck tumors. All patients had a minimum of 3 years of ophthalmologic follow-up (range, 3 to 21 years). The clinical end point was visual acuity of 20/100 or worse as a result of optic nerve injury. Anterior ischemic optic neuropathy developed in five nerves (at mean and median times of 32 and 30 months, respectively, and a range of 2-4 years). Retrobulbar optic neuropathy developed in 12 nerves (at mean and median times of 47 and 28 months, respectively, and a range of 1-14 years). No injuries were observed in 106 optic nerves that received a total dose of <59 Gy. Among nerves that received doses of ≥ 60 Gy, the dose per fraction was more important than the total dose in producing optic neuropathy. The 15-year actuarial risk of optic compared with 47% when given in fraction sizes ≥1.9 Gy. The data also suggest an increased risk of optic nerve injury with increasing age. As there is no effective treatment of radiation-induced optic neuropathy, efforts should be directed at its prevention by minimizing the total dose, paying attention to the dose per fraction to the nerve, and using reduced field techniques where appropriate to limit the volume of tissues that receive high-dose irradiation. 32 refs., 5 figs., 5 tabs

  15. External dose rates in coastal urban environments in Brazil

    International Nuclear Information System (INIS)

    Souza, E.M.; Rochedo, E.R.R.; Conti, C.C.

    2015-01-01

    A long term activity aiming on assessing the exposure of the Brazilian population to natural background radiation is being developed at IRD/CNEN. Several research groups within IRD work in this activity, although mostly as a parallel work associated to main research lines followed by researches of the institution. One main activity is related to the raise of external gamma dose rates throughout the country. The objective of this work is to present results from recent surveys performed as part of the emergency preparedness for radiological emergencies during major public events in Brazil, such as the the World Youth Day, held in Rio de Janeiro in 2013, and the Confederations Cup and the FIFA World Cup soccer games, in 2013 and 2014, respectively. In this work, only the recent (2014) coastal urban environments measurements were included. Average kerma rates for Fortaleza is 80 ± 23 nGy/h, for Vitoria is 96 ± 33 nGy/h and for Angra dos Reis is 147 ± 16 nGy/h. These results are then compared to previous results on other coastal urban towns (Rio de Janeiro, Niterói and Salvador), and with the high background coastal area of Guarapari town. (authors)

  16. Relationship between Individual External Doses, Ambient Dose Rates and Individuals' Activity-Patterns in Affected Areas in Fukushima following the Fukushima Daiichi Nuclear Power Plant Accident.

    Directory of Open Access Journals (Sweden)

    Wataru Naito

    Full Text Available The accident at Fukushima Daiichi Nuclear Power Plant on March 11, 2011, released radioactive material into the atmosphere and contaminated the land in Fukushima and several neighboring prefectures. Five years after the nuclear disaster, the radiation levels have greatly decreased due to physical decay, weathering, and decontamination operations in Fukushima. The populations of 12 communities were forced to evacuate after the accident; as of March 2016, the evacuation order has been lifted in only a limited area, and permanent habitation is still prohibited in most of the areas. In order for the government to lift the evacuation order and for individuals to return to their original residential areas, it is important to assess current and future realistic individual external doses. Here, we used personal dosimeters along with the Global Positioning System and Geographic Information System to understand realistic individual external doses and to relate individual external doses, ambient doses, and activity-patterns of individuals in the affected areas in Fukushima. The results showed that the additional individual external doses were well correlated to the additional ambient doses based on the airborne monitoring survey. The results of linear regression analysis suggested that the additional individual external doses were on average about one-fifth that of the additional ambient doses. The reduction factors, which are defined as the ratios of the additional individual external doses to the additional ambient doses, were calculated to be on average 0.14 and 0.32 for time spent at home and outdoors, respectively. Analysis of the contribution of various activity patterns to the total individual external dose demonstrated good agreement with the average fraction of time spent daily in each activity, but the contribution due to being outdoors varied widely. These results are a valuable contribution to understanding realistic individual external doses

  17. Radiation retinopathy after external-beam irradiation: Analysis of time-dose factors

    International Nuclear Information System (INIS)

    Parsons, J.T.; Bova, F.J.; Mendenhall, W.M.

    1994-01-01

    To investigate the risk of radiation-induced retinopathy according to total radiation dose and fraction size, based on both retorspective and prospectively collected data. Between October 1964 and May 1989, 68 retinae in 64 patients received fractionated external-beam irradiation during the treatment of primary extracranial head and neck tumors. All patients had a minimum of 3 years of ophthalmologic follow-up (range, 3 to 26 years; mean, 9 years; median, 8 years). Twenty-seven eyes in 26 patients developed radiation retinopathy resulting in visual acuity of 20/200 or worse. The mean and median times to the onset of symptoms attributable to retinal ischemia were 2.8 and 2.5 years, respectively. Fourteen of the injured eyes developed rubeosis iridis and/or neovascular glaucoma. Radiation retinopathy was not observed at doses below 45 Gy, but increased steadily in incidence at doses ≥45Gy. In the range of doses between 45 and 55 Gy, there was an increased risk of injury among patients who received doses per fraction of ≥1.9Gy (p - .09). There was also a trend toward increased risk of injury among patients who received chemotherapy (two of two vs. four of ten in the 45-51 Gy range; p - .23). The lowest dose associated with retinopathy was 45 Gy delivered to a diabetic patient by twice-a-day fractionation. The data did not suggest an increased risk of radiation retinopathy with increasing age. The current study suggests the importance of total dose as well as dose per fraction, and adds support to a small body of literature suggesting that patients with diabetes mellitus or who receive chemotherapy are at increased risk of injury. A sigmoid dose-response curve is constructed from our current data and data from the literature. 36 refs., 5 figs., 4 tabs

  18. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  19. Pulsed total dose damage effect experimental study on EPROM

    International Nuclear Information System (INIS)

    Luo Yinhong; Yao Zhibin; Zhang Fengqi; Guo Hongxia; Zhang Keying; Wang Yuanming; He Baoping

    2011-01-01

    Nowadays, memory radiation effect study mainly focus on functionality measurement. Measurable parameters is few in china. According to the present situation, threshold voltage testing method was presented on floating gate EPROM memory. Experimental study of pulsed total dose effect on EPROM threshold voltage was carried out. Damage mechanism was analysed The experiment results showed that memory cell threshold voltage negative shift was caused by pulsed total dose, memory cell threshold voltage shift is basically coincident under steady bias supply and no bias supply. (authors)

  20. New model for mines and transportation tunnels external dose calculation using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Allam, Kh. A.

    2017-01-01

    In this work, a new methodology is developed based on Monte Carlo simulation for tunnels and mines external dose calculation. Tunnels external dose evaluation model of a cylindrical shape of finite thickness with an entrance and with or without exit. A photon transportation model was applied for exposure dose calculations. A new software based on Monte Carlo solution was designed and programmed using Delphi programming language. The variation of external dose due to radioactive nuclei in a mine tunnel and the corresponding experimental data lies in the range 7.3 19.9%. The variation of specific external dose rate with position in, tunnel building material density and composition were studied. The given new model has more flexible for real external dose in any cylindrical tunnel structure calculations. (authors)

  1. Analysis of the external doses received by workers involved in the mitigation of the Goiania radiological accident

    Energy Technology Data Exchange (ETDEWEB)

    Mauricio, C.L.P., E-mail: claudia@ird.gov.br [Instituto de Radioproteção e Dosimetria, Rio de Janeiro, RJ (Brazil). Div. de Dosimetria

    2017-07-01

    In 1987, after identification that a stolen head of a Cs-137 radiotherapy irradiator was violated, it starts, in Goiania, the screening of the involved persons, the decontamination and the collection of the radiative waste. The contaminated areas were isolated and the professionals who worked within these areas received individual film monitors and TLD rings, provided by the Instituto de Radioproteção e Dosimetria (IRD), to evaluate their external dose. The aim of this paper is to present a statistical analysis of the external occupational doses received by this intervention staff. The used data were extracted from the Goiania accident database, maintained by IRD. A total of 1091 workers were monitored, some for only a few days and others for almost one year. All the total external occupational doses, received during these works, including the management of the radiative waste, were lower than the individual annual dose limit of 50 mSv for practices. Only one dose exceeded the value of 20 mSv. Their estimated mean effective doses were about 1.0 mSv, which is the annual dose limit for public exposure. About 80% of the doses were lower than this value. (author)

  2. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  3. The effective dose equivalent from external and internal radiation

    International Nuclear Information System (INIS)

    Mattsson, Soeren

    1989-01-01

    The various sources of low-level ionizing radiation are discussed and compared in terms of mean effective dose equivalent to man. For the most nonoccupationally exposed individuals, natural sources given the dominating contribution to the effective dose equivalent. The size of this contribution is strongly dependent on human activities. Natural sources contribution on average 2.4 mSV per year, of which half is due to irradiation of lungs and airways from short lived radon daughters present in indoor air. In Sweden this radon daughter contribution is considerably higher and contributes a mean of 3 mSv per year, thus giving a total contribution from natural radiation of about 4 mSV per year. In extreme cases, radon daughter contributions of several hundreds of mSv per year may be reached. Medical exposure, mainly diagnostic X-rays, contributes 0.4-1 mSv per year both in Sweden and as a world average. The testing of nuclear weapons in the atmosphere has given 1-2 mSv to each person in the world as a mean. The contribution from the routine operation of nuclear reactors is insignificant. The reactor accident in Chernobyl resulted in widely varying exposures of the European population. The average for Sweden is estimated to be 0.1 mSv during the first year and about 1 mSv during a 50-year period. For groups of Swedes who eat a considerable amount of game this contribution will be 10 times higher, and for the Lapps who breed reindeer in the most contaminated areas, typical values of 20-70 mSv and extreme values of about 1 Sv may be reached in 50 years. This means that the Chernobyl reactor accident for several years will be their dominating source of irradiation

  4. 10 CFR 20.1502 - Conditions requiring individual monitoring of external and internal occupational dose.

    Science.gov (United States)

    2010-01-01

    ... external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive... 10 Energy 1 2010-01-01 2010-01-01 false Conditions requiring individual monitoring of external and internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR...

  5. Characteristics of natural background external radiation and effective dose equivalent

    International Nuclear Information System (INIS)

    Fujimoto, Kenzo

    1989-01-01

    The two sources of natural radiation - cosmic rays and primordial radionuclides - are described. The factors affecting radiation doses received from natural radiation and the calculation of effective dose equivalent due to natural radiation are discussed. 10 figs., 3 tabs

  6. Study of total ionization dose effects in electronic devices

    International Nuclear Information System (INIS)

    Nidhin, T.S.; Bhattacharyya, Anindya; Gour, Aditya; Behera, R.P.; Jayanthi, T.

    2018-01-01

    Radiation effects in electronic devices are a major challenge in the dependable application developments of nuclear power plant instrumentation and control systems. The main radiation effects are total ionization dose (TID) effects, displacement damage dose (DDD) effects and single event effects (SEE). In this study, we are concentrating on TID effects in electronic devices. The focus of the study is mainly on SRAM based field programmable gate arrays (FPGA) along with that the devices of our interest are voltage regulators, flash memory and optocoupler. The experiments are conducted by exposing the devices to gamma radiation in power off condition and the degradation in the performances are analysed

  7. Evaluation of dose conversion coefficients for external exposure using Taiwanese reference man and woman

    International Nuclear Information System (INIS)

    Chang, S.J.; Hung, S.Y.; Liu, Y.L.; Jiang, S.H.; Wu, J.

    2015-01-01

    Reference man has been widely used for external and internal dose evaluation of radiation protection. The parameters of the mathematical model of organs suggested by the International Commission of Radiological Protection (ICRP) are adopted from the average data of Caucasians. However, the organ masses of Asians are significantly different from the data of Caucasians, leading to potentially dosimetric errors. In this study, a total of 40 volunteers whose heights and weights corresponded to the statistical average of Taiwanese adults were recruited. Magnetic resonance imaging was performed, and T2-weighted images were acquired. The Taiwanese reference man and woman were constructed according to the measured organ masses. The dose conversion coefficients (DCFs) for anterior-posterior (AP), posterior-anterior (PA), right lateral (RLAT) and left lateral (LLAT) irradiation geometries were simulated. For the Taiwanese reference man, the average differences of the DCFs compared with the results of ICRP-74 were 7.6, 5.1 and 11.1 % for 0.1, 1 and 10 MeV photons irradiated in the AP direction. The maximum difference reached 51.7 % for the testes irradiated by 10 MeV photons. The size of the trunk, the volume and the geometric position of organs can cause a significant impact on the DCFs for external exposure of radiation. The constructed Taiwanese reference man and woman can be used in radiation protection to increase the accuracy of dose evaluation for the Taiwanese population. (authors)

  8. Study on external exposure doses from terrestrial radioactivity in Southern Vietnam

    International Nuclear Information System (INIS)

    Huy, N.Q.; Luyen, T.V.

    2012-01-01

    This paper presents the radioactivity concentrations of 226 Ra, 232 Th and 40 K for 106 samples of surface soil collected in Southern Vietnam. The mean values of mass activity of radionuclides 226 Ra, 232 Th and 40 K for Southern Vietnam are 28.6, 50.7 and 292.6 Bq kg -1 , respectively, which lead to the population-weighted absorbed dose rate of 54.5 nGy h -1 . The average annual effective doses outdoors, indoors and in total of Southern Vietnam are estimated to be 0.067, 0.374 and 0. 441 mSv, respectively. The radium equivalent activity and the external hazard index of soil in Southern Vietnam are in the range 23.2-254.1 Bq kg -1 and 0.06-0.69, respectively. (author)

  9. Study on external exposure doses from terrestrial radioactivity in Southern Vietnam

    International Nuclear Information System (INIS)

    Huy, N. Q.; Luyen, T. V.

    2006-01-01

    This paper presents the radioactivity concentrations of 226 Ra, 232 Th and 40 K for 106 samples of surface soil collected in Southern Vietnam. The mean values of mass activity of radionuclides 226 Ra, 232 Th and 40 K for Southern Vietnam are 28.6, 50.7 and 292.6 Bq kg -1 , respectively, which lead to the population-weighted absorbed dose rate of 54.5 nGy h -1 . The average annual effective doses outdoors, indoors and in total of Southern Vietnam are estimated to be 0.067, 0.374 and 0.441 mSv, respectively. The radium equivalent activity and the external hazard index of soil in Southern Vietnam are in the range 23.2-254.1 Bq kg -1 and 0.06-0.69, respectively. (authors)

  10. External radiation dose from patients received diagnostic doses of 201 T1-Chloride and 99 Tc-MIBI

    International Nuclear Information System (INIS)

    Dadashzadeh, S.; Sattari, A.; Nasiroghli, G.A.

    2002-01-01

    Patients receiving diagnostic doses of radiopharmaceuticals become a source of contamination and exposure for those who come in contact with them, such as nuclear medicine technologists, relatives and nurses. Therefore, the measurement of external radiation dose from these patients is necessary. In this study, the dose rates at distances of 10, 50 and 100 cm from 70 patients who received diagnostic amounts of 201 T1-Chloride and 99 Tc-MIBI was measures. The results showed that the maximum external radiation dose rates for 201 T1 and 99 Tc-MIBI were 18.4 and 75.0 μ Sv.h -1 , respectively, at 5 cm distance from the patients. The average radiation dose received by nuclear medicine technologists, considering their close contact during one working day was 12.5 ± 3.4μ Sv. The highest received dose was 22.7 μSv, which was well below the acceptable dose limit

  11. HADOC: a computer code for calculation of external and inhalation doses from acute radionuclide releases

    International Nuclear Information System (INIS)

    Strenge, D.L.; Peloquin, R.A.

    1981-04-01

    The computer code HADOC (Hanford Acute Dose Calculations) is described and instructions for its use are presented. The code calculates external dose from air submersion and inhalation doses following acute radionuclide releases. Atmospheric dispersion is calculated using the Hanford model with options to determine maximum conditions. Building wake effects and terrain variation may also be considered. Doses are calculated using dose conversion factor supplied in a data library. Doses are reported for one and fifty year dose commitment periods for the maximum individual and the regional population (within 50 miles). The fractional contribution to dose by radionuclide and exposure mode are also printed if requested

  12. Estimation of effective dose equivalente from external irradiations

    International Nuclear Information System (INIS)

    Wakabayashi, T.

    1985-07-01

    A methodology for computing effective dose equivalent, derived from the computer code ALGAM: Monte Carlo Estimation of Internal Dose from Gamma-ray Sources in a Phantom Man, developed at Oak Ridge National Laboratory, is presented. The modified code was run for 12 different photon energy levels, from 0,010 Mev to 4.0 Mev, which provides computing the absorved dose, for these energy levels, in each one of the 97 organs of the original code. The code also was run for the principal energy levels used in the calibration of the dosimetric films. The results of the absorved doses per photon obtained for these levels of energy have been transformed in effective dose equivalents. (M.A.C.) [pt

  13. DOSE-ESCALATED EXTERNAL BEAM RADIOTHERAPY DURING HORMONO-RADIOTHERAPY FOR PROSTATE CANCER

    Directory of Open Access Journals (Sweden)

    Yu. V. Gumenetskaya

    2016-01-01

    Full Text Available Introduction. The introduction of modern technologies of conformal external beam radiotherapy (EBRT into clinical practice for the treatment of prostate cancer requires proper quality assurance measures as well as a careful analysis of both the efficacy and toxicity data of treatments. The purpose of this study was to inves- tigate tolerance and the immediate efficacy of conformal dose-escalated EBRT during hormono-radiotherapy for prostate cancer. material and methods. The study involved 156 prostate cancer patients treated with EBRT. Among them, 30 patients received a total dose of 70 Gy, and in 126 patients the total dose was esca- lated to 72-76 Gy (median total dose - 74.0 Gy. Fifty-nine patients received intensity modulated radiation therapy. Results. The prescribed course of treatment was completed in all the patients with prostate cancer. Acute radiation-induced bladder reactions (RTOG were observed in 50 (32.1 % patients, of whom 48 (30.8 % experienced grade I reactions, and 2 (1.3 % experienced grade II reactions. Eighteen (11.5 % patients had radiation-induced rectum reactions, not above grade I. The development of grade II dysuric phenomena necessitated treatment interruption only in two patients. Of 9 (5.8 % patients who had late bladder complica- tions (RTOG/EORTC, 8 (5.1 % patients developed grade I complications, and one (0.6 % patient developed grade II complications. Of 11 (7.1 % patients who had rectum complications, 8 (5.1 % patients developed grade I complications, and 3 (1.9 % patients developed grade II complications. No patients experienced the increase in toxicity of treatment during dose escalation up to a total dose exceeding 70 Gy. During the follow-up period, only one patient developed recurrent disease. Conclusion. The results of our study suggest acceptable levels of toxicity following a continuous course of dose-escalated EBRT given in conjunction with hormono-radiotherapy to prostate cancer patients. Further

  14. Dose rate and dose fractionation studies in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.

    1979-01-01

    Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients

  15. Impact of Total, Internal and External Government Debt on Interest Rate in Pakistan

    OpenAIRE

    Perveen, Asma; Munir, Kashif

    2017-01-01

    The objective of the study is to examine impact of total, internal and external government debt on nominal interest rate in Pakistan. To attain these objectives, the study used annual time series data from 1973 to 2016. The study used loanable fund theory as theoretical model and ARDL bound testing approach for cointegration and Granger causality test to estimate the results. The results of the study found negative relation between total government debt, external debt and nominal interest rat...

  16. Data for absorbed dose calculations for external sources and for emitters within the body

    International Nuclear Information System (INIS)

    Hep, J.; Valenta, V.

    1976-01-01

    Tables give data for the calculation of absorbed doses from radioactivity sources accumulated in individual body organs. The tables are arranged in such manner that the gamma energy (J) absorbed in 1 kg of target organ (19 organs and total body) are given for 18 source organs (16 different organs, total doby and surrounding air) resulting from 1 decay event, this for more than 250 radioisotopes evenly distributed in the source organ (1 J/kg=100 rad). Also given are the energies of alpha and beta radiations related to one decay. In tables having the surrounding air as the source it is assumed that the intensity of the external source is 1 decay per 1 m 3 of surrounding air which is constant in the entire half-space. The tables are only elaborated for radioisotopes with a half-life of more than 1 min. (B.S.)

  17. Estimates of bias and uncertainty in recorded external dose

    International Nuclear Information System (INIS)

    Fix, J.J.; Gilbert, E.S.; Baumgartner, W.V.

    1994-10-01

    A study is underway to develop an approach to quantify bias and uncertainty in recorded dose estimates for workers at the Hanford Site based on personnel dosimeter results. This paper focuses on selected experimental studies conducted to better define response characteristics of Hanford dosimeters. The study is more extensive than the experimental studies presented in this paper and includes detailed consideration and evaluation of other sources of bias and uncertainty. Hanford worker dose estimates are used in epidemiologic studies of nuclear workers. A major objective of these studies is to provide a direct assessment of the carcinogenic risk of exposure to ionizing radiation at low doses and dose rates. Considerations of bias and uncertainty in the recorded dose estimates are important in the conduct of this work. The method developed for use with Hanford workers can be considered an elaboration of the approach used to quantify bias and uncertainty in estimated doses for personnel exposed to radiation as a result of atmospheric testing of nuclear weapons between 1945 and 1962. This approach was first developed by a National Research Council (NRC) committee examining uncertainty in recorded film badge doses during atmospheric tests (NRC 1989). It involved quantifying both bias and uncertainty from three sources (i.e., laboratory, radiological, and environmental) and then combining them to obtain an overall assessment. Sources of uncertainty have been evaluated for each of three specific Hanford dosimetry systems (i.e., the Hanford two-element film dosimeter, 1944-1956; the Hanford multi-element film dosimeter, 1957-1971; and the Hanford multi-element TLD, 1972-1993) used to estimate personnel dose throughout the history of Hanford operations. Laboratory, radiological, and environmental sources of bias and uncertainty have been estimated based on historical documentation and, for angular response, on selected laboratory measurements

  18. An improved standard total dose test for CMOS space electronics

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Winokur, P.S.; Riewe, L.C.; Pease, R.L.

    1989-01-01

    The postirradiation response of hardened and commercial CMOS devices is investigated as a function of total dose, dose rate, and annealing time and temperature. Cobalt-60 irradiation at ≅ 200 rad(SiO 2 )/s followed by a 1-week 100 degrees C biased anneal and testing is shown to be an effective screen of hardened devices for space use. However, a similar screen and single-point test performed after Co-60 irradiation and elevated temperature anneal cannot be generally defined for commercial devices. In the absence of detailed knowledge about device and circuit radiation response, a two-point standard test is proposed to ensure space surviability of CMOS circuits: a Co-60 irradiation and test to screen against oxide-trapped charge related failures, and an additional rebound test to screen against interface-trap related failures. Testing implications for bipolar technologies are also discussed

  19. Analysis of records of external occupational dose records in Brazil; Analise dos registros de dose ocupacional externa no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Mauricio, Claudia L.P.; Silva, Herica L.R. da, E-mail: claudia@ird.gov.br, E-mail: herica@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ),Rio de Janeiro, RJ (Brazil); Silva, Claudio Ribeiro da, E-mail: claudio@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Brazil, a continental country, with actually more than 150,000 workers under individual monitoring for ionizing radiation, has implemented in 1987 a centralized system for storage of external occupational dose. This database has been improved over the years and is now a web-based information system called Brazilian External Occupational Dose Management Database System - GDOSE. This paper presents an overview of the Brazilian external occupational dose over the years. The estimated annual average effective dose shows a decrease from 2.4 mSv in 1987 to about 0.6 mSv, having been a marked reduction from 1987 to 1990. Analyzing by type of controlled practice, one sees that the medical and dental radiology is the area with the largest number of users of individual monitors (70%); followed by education practices (8%) and the industrial radiography (7%). Additionally to photon whole body monitoring; neutron monitors are used in maintenance (36%), reactor (30%) and education (27%); and extremity monitors, in education (27%), nuclear medicine (22%) and radiology (19%). In terms of collective dose, the highest values are also found in conventional radiology, but the highest average dose values are those of interventional radiology. Nuclear medicine, R and D and radiotherapy also have average annual effective dose higher than 1 mSv. However, there is some very high dose values registered in GDOSE that give false information. This should be better analyzed in the future. Annual doses above 500 are certainly not realistic. (author)

  20. Reconstruction of the external dose of evacuees from the contaminated areas based on simulation modelling

    International Nuclear Information System (INIS)

    Meckbach, R.; Chumak, V.V.

    1996-01-01

    Model calculations are being performed for the reconstruction of individual external gamma doses of population evacuated during the Chernobyl accident from the city of Pripyat and other settlements of the 30-km zone. The models are based on sets of dose rate measurements performed during the accident, on individual behavior histories of more than 30000 evacuees obtained by questionnaire survey and on location factors determined for characteristic housing buildings. Location factors were calculated by Monte Carlo simulations of photon transport for a typical housing block and village houses. Stochastic models for individual external dose reconstruction are described. Using Monte Carlo methods, frequency distributions representing the uncertainty of doses are calculated from an assessment of the uncertainty of the data. The determination of dose rate distributions in Pripyat is discussed. Exemplary results for individual external doses are presented

  1. Total dose and dose rate models for bipolar transistors in circuit simulation.

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Phillip Montgomery; Wix, Steven D.

    2013-05-01

    The objective of this work is to develop a model for total dose effects in bipolar junction transistors for use in circuit simulation. The components of the model are an electrical model of device performance that includes the effects of trapped charge on device behavior, and a model that calculates the trapped charge densities in a specific device structure as a function of radiation dose and dose rate. Simulations based on this model are found to agree well with measurements on a number of devices for which data are available.

  2. An assessment of effective dose to staff in external beam radiotherapy

    International Nuclear Information System (INIS)

    Rawlings, D.J.; Nicholson, L.

    1997-01-01

    Radiation safety in external beam radiotherapy is governed by national legislation. Annual doses recorded by radiographers and others associated with external beam radiotherapy are typically much lower than the relevant dose limit. However, it is possible that larger doses might be received as a result of an accidental irradiation. In the event of a significant exposure resulting in a dose at or near a relevant dose limit, an accurate conversion has to be made from the dose meter reading to the limiting quantity. A method was devised to demonstrate ratios of effective dose to personal dose equivalent which might be anticipated in the even of an individual other than the patient being irradiated within a radiotherapy treatment room consisting of a linear accelerator. The variation of ratios obtained under different conditions is discussed. (author)

  3. Thyroid doses from external gamma-exposure following the Chernobyl accident

    International Nuclear Information System (INIS)

    Tretyakevich, Sergey; Kukhta, Tatyana; Minenko, Victor; Drozdovitch, Vladimir; Luckyanov, Nickolas; Gavrilin, Yury; Khrouch, Valeri; Shinkarev, Sergey

    2008-01-01

    Full text: An increase of thyroid cancer incidence among children in Belarus has been observed after the Chernobyl accident. The main contributor to the thyroid dose was caused by 131 I intake with fresh milk in 1986. Other contributions to the thyroid dose (external gamma-exposure, short-lived iodine isotopes, internal radiocesium) were small in comparison to the dose from 131 I intakes soon after the accident. However, exposures to external radiation continued for a number of years after the accident. Thyroid doses from external gamma-exposure following the Chernobyl accident were mainly caused by gamma-exposure to 24 nuclides: 95 Zr, 95 Nb, 99 Mo, 99 mTc, 103 Ru, 103m Rh, 106 Ru, 125 Sb, 125m Te, 131m Te, 131 I, 132 Te, 132 I, 133 I, 135 I, 134 Cs, 136 Cs, 137 Cs, 140 Ba, 140 La, 141 Ce, 144 Ce, 144 Pr, 239 Np. Data of personal interview were used to take into account the personal residence history for the time elapsed from the Chernobyl accident until the interview (10 to 15 years later). Cumulative thyroid doses caused by external gamma-exposure during the passage of the radioactive cloud and from the ground contamination following the Chernobyl accident have been reconstructed. The median thyroid dose from external gamma-exposure to ∼11,770 cohort members of an epidemiological study was estimated to be ∼6 mGy. There are ∼3,400 persons with external dose estimates that exceed 20 mGy. Exposure from radionuclides deposited on the ground was the main source of external dose. The contribution from the passing radioactive cloud to external dose was found to be negligible. (author)

  4. External gamma radiation dose studies in the proposed uranium mining areas of Andhra Pradesh, India

    International Nuclear Information System (INIS)

    Reddy, P.; Reddy, K.; Reddy, C.; Reddy, K.

    2006-01-01

    Natural radiation sources contribute the largest component to the total effective dose received by the human population. Among these sources, natural background gamma radiation shares a noteworthy amount. The present study aims at the establishment of baseline environmental gamma radiation data in the environs of proposed uranium mining areas of Andhra Pradesh, India. To this end, a systematic study has been undertaken using Thermoluminescence (T.L.) dosimeters and G.M. (Geiger - Muller) tube based survey meter. These levels are estimated both indoors and outdoors in the study area covering about 23 villages surrounding the proposed mining sites. The estimated external gamma radiation levels (air kerma) varied from 0.605 to 4.39 mGy.y -1 . The mean indoor to outdoor radiation level ratio is found to be 1.1 ± 0.1. The estimated mean equivalent doses due to external background radiation in the villages of the study area range from 1.03 to 2.83 mSv.y -1 with a mean of 2.34 ± 0.39 mSv.y -1 . (authors)

  5. Theoretical considerations for SRAM total-dose hardening

    International Nuclear Information System (INIS)

    Francis, P.; Flandre, D.; Colinge, J.P.

    1995-01-01

    The theoretical hardness against total dose of the six-transistor SRAM cell is investigated in detail. An explicit analytical expression of the maximum tolerable threshold voltage shift is derived for two cross-coupled inverters. A numerical method is used to explore the hardness of the read and write operations. Both N- and P-channel access transistors designs are considered and their respective advantages are compared. The study points out that the radiation hardness mainly relies on the technology. Results obtained with the very robust Gate-All-Around process are finally presented

  6. Mercure IV code application to the external dose computation from low and medium level wastes

    International Nuclear Information System (INIS)

    Tomassini, T.

    1985-01-01

    In the present work the external dose from low and medium level wastes is calculated using MERCURE IV code. The code utilizes MONTECARLO method for integrating multigroup line of sight attenuation Kernels

  7. External-beam boost prior to total-body irradiation in relapsed NHL transplant patients

    Energy Technology Data Exchange (ETDEWEB)

    Monson, Jedidiah M; Neuberg, Donna; Freedman, Arnold S; Tarbell, Nancy J; Nadler, Lee M; Mauch, Peter

    1995-07-01

    PURPOSE: To determine the impact of an external beam boost (EBB) on the outcome, relapse pattern and normal tissue toxicities of patients undergoing total-body irradiation (TBI) prior to bone marrow transplantation (BMT) for relapsed NHL. MATERIALS AND METHODS: Between 1982 and 1994, 299 patients at our institution underwent BMT for relapsed NHL. Patients underwent induction chemotherapy (CT) followed by conditioning with cyclophosphamide and 12 Gy TBI delivered in 6 fractions over 3 days. A total of 77 patients had persistent gross disease, defined as 2 cm or greater, after induction CT and received an EBB prior to BMT (EBB cohort). The median EBB dose was 28.8 Gy (range, 5-63), the median field size was 13 cm{sup 2} (range, 5-29.4) and the median time from EBB to BMT was 3 weeks (range, 1-20). A total of 222 patients were free of measurable disease or had disease measuring <2cm after CT and did not receive EBB (no-EBB cohort). To assess normal tissue toxicity, patients' simulation films and/or treatment records were reviewed for all 77 patients treated with local EBB and estimates were made of the percentage lung, heart and kidney in the radiation field. RESULTS: A total of 79 of 222 patients (36%) in the no-EBB cohort have relapsed; 33 of 77 patients (43%) in the EBB cohort have relapsed (p=0.28, by Fisher exact test). Median time to relapse after BMT was 54 months for the no-EBB cohort and 38 months for the EBB cohort (p=0.26, by log-rank test). The 3-year actuarial freedom from relapse (deaths in remission censored) was 59% for the no-EBB cohort (90% CI: 52-66%) and 51% for the EBB cohort (90% CI: 40-62%). Data on site of relapse was available for 101 of the 112 relapses (75 no-EBB, 26 EBB). For the no-EBB cohort 33 of 75 relapses (44%) were in sites of prior nodal disease only. For the EBB cohort, 12 of 26 relapses (46%) were in sites of prior nodal disease only, of these, only 6 (23%) were within the EBB treatment field. A total of 26 patients had thoracic

  8. Estimates of external dose-rate conversion factors and internal dose conversion factors for selected radionuclides released from fusion facilities

    Energy Technology Data Exchange (ETDEWEB)

    Homma, Toshimitsu; Togawa, Orihiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-11-01

    This report provides a tabulation of both external dose-rate conversion factors and internal dose conversion factors using radioactive decay data in the updated Evaluated Nuclear Structure Data File (ENSDF) for selected 26 radionuclides and all their daughter radionuclides of potential importance in safety assessments of fusion facilities. The external dose-rate conversion factors for 21 target organs are tabulated for three exposure modes that are immersion in contaminated air, irradiation at a height of 1 m above a contaminated ground surface and immersion contaminated water. For internal exposure, committed dose equivalents, based on the methodology of ICRP Publication 30, in the same target organs per intake of unit activity are given for the inhalation and ingestion exposure pathways. The data presented here is intended to be generally used for safety assessments of fusion reactors. Comparisons of external effective dose-rate conversion factors and committed effective dose equivalents are made with the previous data from the independent data bases to provide quality assurance on our calculated results. There is generally good agreement among data from the independent data bases. The differences in the values of both effective dose-rate and dose conversion factors appeared are primarily due to differences in calculational methodology, the use of different radioactive decay data, and compilation errors. (author)

  9. Total effective dose equivalent associated with fixed uranium surface contamination

    International Nuclear Information System (INIS)

    Bogard, J.S.; Hamm, R.N.; Ashley, J.C.; Turner, J.E.; England, C.A.; Swenson, D.E.; Brown, K.S.

    1997-04-01

    This report provides the technical basis for establishing a uranium fixed-contamination action level, a fixed uranium surface contamination level exceeding the total radioactivity values of Appendix D of Title 10, Code of Federal Regulations, part 835 (10CFR835), but below which the monitoring, posting, and control requirements for Radiological Areas are not required for the area of the contamination. An area of fixed uranium contamination between 1,000 dpm/100 cm 2 and that level corresponding to an annual total effective dose equivalent (TEDE) of 100 mrem requires only routine monitoring, posting to alert personnel of the contamination, and administrative control. The more extensive requirements for monitoring, posting, and control designated by 10CFR835 for Radiological Areas do not have to be applied for these intermediate fixed-contamination levels

  10. A user's guide to the inhalation and external radiation collective dose module NECTAR-POPDOS

    International Nuclear Information System (INIS)

    Merlin, J.H.

    1982-02-01

    NECTAR-POPDOS is a module of the computer program NECTAR, which has been written in modular form to evaluate radioactive releases from nuclear fuel, their dispersion in the environment and the consequent individual and collective doses to man. The NECTAR-POPDOS module may be used to evaluate external and inhalation collective doses to any specified area of Great Britain, either to the total population or to any one of six age groups, using population data from the 1971 UK census. If a dose-risk function is defined, the module may be used to assess population health effects or for optimisation studies. The module is based on the stand-alone program POPDOS2, and is written in Fortran IV. The input data to the module is described and the module's limitations and sources of inaccuracy are discussed. Appendices to the report contain the necessary Job Control Language for running NECTAR, a list of NECTAR-POPDOS subroutines, and the input and output of two sample NECTAR-POPDOS cases. (author)

  11. Secondary radiation dose during high-energy total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Janiszewska, M.; Raczkowski, M. [Lower Silesian Oncology Center, Medical Physics Department, Wroclaw (Poland); Polaczek-Grelik, K. [University of Silesia, Medical Physics Department, Katowice (Poland); Szafron, B.; Konefal, A.; Zipper, W. [University of Silesia, Department of Nuclear Physics and Its Applications, Katowice (Poland)

    2014-05-15

    The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: {sup 56}Mn in the stainless steel and {sup 187}W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 μSv from activated radionuclides. Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once. (orig.) [German] Die zusaetzliche Dosis durch sekundaere Neutronen- und γ-Strahlung waehrend der Ganzkoerperbestrahlung mit Roentgenstrahlung aus medizinischen Linearbeschleunigern wurde abgeschaetzt. Bei der Emission hochenergetischer Strahlen zur Teletherapie finden hauptsaechlich im Beschleuniger

  12. Total Risk Management for Low Dose Radiation Exposures

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; Sterc, D.

    2012-01-01

    health. This view is supported with numerous evidences, and explained with beneficial effects from the increased activity of immune system activated with small radiation exposures. Finally, theory in between is that small doses are less than linearly proportionally harmful and that they are presenting a much smaller risks than according to the LNT. This view is derived from the use of different evidences. Difficulties to find one single theory about effects of small radiation doses are related to existence of huge variability and uncertainty in the evidence data. This is very hard experimental and theoretical problem. It will require lots of additional research to reduce these uncertainties and find final theory. This might be too late for the number of people affected in different ways with current single most conservative LNT approach. The problem with the conservative LNT regulatory approach is resulting in enormous additional costs of nuclear energy and medical applications. Which is reasonable and acceptable during the regular operation when source is high and concentrated. But, this becomes unreasonable huge economic burden after accidents and for cleanups with nuclear facilities. Similar problem arises with restriction of medical examinations and treatments based on over conservative risk estimate. Special circumstances are with evacuated people from contaminated areas where they are on the one side saved from small radiation exposures, and on the other side exposed to years of life away from their home and with numerous direct and indirect additional risks (i.e., stress, social problems, etc.). It seems reasonable that some alternative (total) risk management approach might be much more suitable for this situation. Evacuation of people from contaminated area with small doses sources should not be done when that induces larger risks from even what is expected from radiation based on LNT. Similar total risk management could be also applied for with medical

  13. Outline of manual on measurement and assessment of doses from external radiation

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, Michio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Tsujimura, Norio

    2001-03-01

    The external exposure part in the manual for measurement and assessment of doses from external radiation is described since the part is changed in accordance with the revision of the Law Concerning Prevention from Radiation Hazard due to Radioisotopes, Etc. The manual contains general remarks, control of external exposure and its methods, person monitoring, site monitoring, correction of instruments and storage of records. The 2nd and 3rd chapters are described in details, because which are considerably changed together with appendices concerning the operational quantity for measuring external dose, conversion coefficients, and correlations of 3 mm, 1 cm and 70 {mu}m dose equivalents. Making manuals unique to the individual offices, etc. is recommended in compliance with the above manual.(K.H.)

  14. Analytical models for total dose ionization effects in MOS devices.

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Phillip Montgomery; Bogdan, Carolyn W.

    2008-08-01

    MOS devices are susceptible to damage by ionizing radiation due to charge buildup in gate, field and SOI buried oxides. Under positive bias holes created in the gate oxide will transport to the Si / SiO{sub 2} interface creating oxide-trapped charge. As a result of hole transport and trapping, hydrogen is liberated in the oxide which can create interface-trapped charge. The trapped charge will affect the threshold voltage and degrade the channel mobility. Neutralization of oxidetrapped charge by electron tunneling from the silicon and by thermal emission can take place over long periods of time. Neutralization of interface-trapped charge is not observed at room temperature. Analytical models are developed that account for the principal effects of total dose in MOS devices under different gate bias. The intent is to obtain closed-form solutions that can be used in circuit simulation. Expressions are derived for the aging effects of very low dose rate radiation over long time periods.

  15. Total Dose Effects on Bipolar Integrated Circuits at Low Temperature

    Science.gov (United States)

    Johnston, A. H.; Swimm, R. T.; Thorbourn, D. O.

    2012-01-01

    Total dose damage in bipolar integrated circuits is investigated at low temperature, along with the temperature dependence of the electrical parameters of internal transistors. Bandgap narrowing causes the gain of npn transistors to decrease far more at low temperature compared to pnp transistors, due to the large difference in emitter doping concentration. When irradiations are done at temperatures of -140 deg C, no damage occurs until devices are warmed to temperatures above -50 deg C. After warm-up, subsequent cooling shows that damage is then present at low temperature. This can be explained by the very strong temperature dependence of dispersive transport in the continuous-time-random-walk model for hole transport. For linear integrated circuits, low temperature operation is affected by the strong temperature dependence of npn transistors along with the higher sensitivity of lateral and substrate pnp transistors to radiation damage.

  16. Cost and effectiveness of decontamination strategies in radiation contaminated areas in Fukushima in regard to external radiation dose.

    Science.gov (United States)

    Yasutaka, Tetsuo; Naito, Wataru; Nakanishi, Junko

    2013-01-01

    The objective of the present study is to evaluate the cost and effectiveness of decontamination strategies in the special decontamination areas in Fukushima in regard to external radiation dose. A geographical information system (GIS) was used to relate the predicted external dose in the affected areas to the number of potential inhabitants and the land use in the areas. A comprehensive review of the costs of various decontamination methods was conducted as part of the analysis. The results indicate that aerial decontamination in the special decontamination areas in Fukushima would be effective for reducing the air dose rate to the target level in a short period of time in some but not all of the areas. In a standard scenario, analysis of cost and effectiveness suggests that decontamination costs for agricultural areas account for approximately 80% of the total decontamination cost, of which approximately 60% is associated with storage. In addition, the costs of decontamination per person per unit area are estimated to vary greatly. Appropriate selection of decontamination methods may significantly decrease decontamination costs, allowing more meaningful decontamination in terms of the limited budget. Our analysis can help in examining the prioritization of decontamination areas from the viewpoints of cost and effectiveness in reducing the external dose. Decontamination strategies should be determined according to air dose rates and future land-use plans.

  17. Controversies in external beam and high dose rate brachytherapy of oesophageal cancer

    International Nuclear Information System (INIS)

    Sur, R.K.; Levin, V.C.; Malas, Simon; Donde, Bernard

    1994-01-01

    Various controversies in the treatment of oesophageal carcinoma with external beam radiotherapy and high dose rate intracavitary irradiation have been reviewed. Conflicting results from different parts of the world has made it difficult to optimize the radiation dose that may give the best results. More studies and longer follow-up are needed before a definite conclusion can be made on the optimization of dose. (author). 18 refs., 2 tabs

  18. The relationship between external beam radiotherapy dose and chronic urinary dysfunction - A methodological critique

    International Nuclear Information System (INIS)

    Rosewall, Tara; Catton, Charles; Currie, Geoffrey; Bayley, Andrew; Chung, Peter; Wheat, Janelle; Milosevic, Michael

    2010-01-01

    Purpose: To perform a methodological critique of the literature evaluating the relationship between external beam radiotherapy dose/volume parameters and chronic urinary dysfunction to determine why consistent associations between dose and dysfunction have not been found. Methods and materials: The radiotherapy literature was reviewed using various electronic medical search engines with appropriate keywords and MeSH headings. Inclusion criteria comprised of; English language articles, published between 1999 and June 2009, incorporating megavoltage external beam photons in standard-sized daily fraction. A methodological critique was then performed, evaluating the factors affected in the quantification of radiotherapy dose and chronic urinary dysfunction. Results: Nine of 22 eligible studies successfully identified a clinically and statistically significant relationship between dose and dysfunction. Accurate estimations of external beam radiotherapy dose were compromised by the frequent use of dosimetric variables which are poor surrogates for the dose received by the lower urinary tract tissue and do not incorporate the effect of daily variations in isocentre and bladder position. The precise categorization of chronic urinary dysfunction was obscured by reliance on subjective and aggregated toxicity metrics which vary over time. Conclusions: A high-level evidence-base for the relationship between external beam radiotherapy dose and chronic urinary dysfunction does not currently exist. The quantification of the actual external beam dose delivered to the functionally important tissues using dose accumulation strategies and the use of objective measures of individual manifestations of urinary dysfunction will assist in the identification of robust relationships between dose and urinary dysfunction for application in widespread clinical practice.

  19. Effects of low-dose fractionated external irradiation on metabolic and structural characteristics of rat thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Nadolnik, L.; Niatsetskaya, Z. [Institute of Biochemistry, National Academy of Sciences of Belarus, Grodno (Belarus)

    2006-07-01

    Full text of publication follows: The problem of thyroid radiosensitivity to the effect of low dose external ionizing irradiation presently seems to be the least studied, and the experimental findings - the most contradictory. The aim of the work was to study the effects of long-term low-dose fractionated irradiation on the iodide metabolism and structure of the thyroid. Female Wistar rats weighing 140-160 g were irradiated 20 times (5 times a week, for 4 weeks) using a 60 Co installation. The single absorbed doses were 0.1, 0.25 and 0.5 Gy and the total ones - 2.0, 5.0 and 10.0 Gy, respectively. The animals were decapitated after 1 day, 4 and 24 weeks following the last irradiation. The thyroid tissue was used to assay for thyro-peroxidase (T.P.O.) activity as well as total, protein -bound and free iodide concentrations. Microscopic and morphometric examination of histologic thyroid preparations was carried out. Blood was assayed for thyroxin (T4) and triiodothyronine (T3) concentrations. After a day following the irradiation, the thyroid showed a pronounced increase in the concentration of total iodide (30.0-54.4%) as well in that of free (32.1-60.8%) and protein-bound ones (24.4-37.4%). The most pronounced iodide concentration elevation was noted in the 0.1 -Gy animals, with thyroid T.P.O. activity being raised by 48.0%. Only the 0.5 Gy-group had 1.4-1.5-fold reduced thyroid hormone levels. Four weeks after the irradiation, studied parameters of irradiated rats were brought back to the control values, except for the 0.5 Gy-group. However, after 24-weeks, the 0.5-and 0.25- irradiated rats experienced a 12-20% thyroid weight elevation in comparison with the control. The thyroid of these animals demonstrated reduced contents of total and free iodide as well as T.P.O. activity by 24.5 and 34.8%. The 0.1 Gy-group had a 1.7-fold increased T.P.O. activity. The concentration of the thyroid hormones was maintained diminished only in the 0.5 Gy -irradiated group. However

  20. Radiation dose to laterally transposed ovaries during external beam radiotherapy for cervical cancer

    International Nuclear Information System (INIS)

    Mazonakis, Michael; Damilakis, John; Varveris, Haris; Gourtsoyiannis, Nicholas

    2006-01-01

    The purpose of this study was to estimate the radiation dose to laterally transposed ovaries from external beam radiotherapy for cervical cancer. Dose measurements were performed in a modified humanoid phantom using a 6 MV photon beam. The dependence of the ovarian dose upon the field size, the distance from the primary irradiation field and the presence of wedges or gonadal shielding was determined. For a tumor dose of 45 Gy, ovarian dose was 0.88-8.51 Gy depending on the field size employed and the location of the transposed ovary in respect to the treatment field. Positioning of 7 cm thick shielding reduced the dose to ovary by less than 19%. The use of wedges increased the ovarian dose by a factor up to 1.5. Accurate radiographic localization of the ovaries allows the use of the presented dosimetric results to obtain a reasonable prediction of the ovarian dose

  1. External dose distributions of exposure to natural uranium slab for calibration of beta absorbed dose

    International Nuclear Information System (INIS)

    Chen Lishu

    1987-01-01

    The depth dose distributions and uniformity of beta radiation fields from a natural uranium slab in equilibration were measured using a tissue equivalent extrapolation chamber and film dosimeter. The advantages for calibration of enviromental dose instument or survey meter and personal dosimeter, for routine monitoring in terms of directional dose equivalent and superficial individual dose equivalent were summarized. Finally, the values measured agree well with that of theoretical calculation

  2. External dose distributions of exposure to natural uranium slab for calibration of beta absorbed dose

    Energy Technology Data Exchange (ETDEWEB)

    Lishu, Chen

    1987-05-01

    The depth dose distributions and uniformity of beta radiation fields from a natural uranium slab in equilibration were measured using a tissue equivalent extrapolation chamber and film dosimeter. The advantages for calibration of enviromental dose instument or survey meter and personal dosimeter, for routine monitoring in terms of directional dose equivalent and superficial individual dose equivalent were summarized. Finally, the values measured agree well with that of theoretical calculation.

  3. Doses from external and internal radiation in Norway during the first year after the Chernobyl accident

    International Nuclear Information System (INIS)

    Strand, P.; Kjoelaas, G.; Reitan, J.B.; Strand, T.; Berthelsen, T.; Selnaes, T.D.

    1990-01-01

    In this article the estimation of monthly doses from external radiation from internal radiation due to ingestion of contaminated food is reported. The monthly doses is estimated for each municipality in Norway for the first 13 months after the Chernobyl accident (from May 1986 to June 1987). The estimation which has been elaborated from an extensive data material, shows that the dose rates from external radiation due to the Chernobyl fallout were for the country as a whole three times higher in the first month after the accident (May 1986) compared with the twelfth month (April 1987). The doses received from intake of radiocesium through food were small in the first three months, but reached almost the double of the doses from the external radiation the 9th month. The reduction in the dose from external radiation was primarily due to the physical half life of radiocesium and washout. The increase in the doses from radiocesium through intake of food was due to the time required for radiocesium to enter the food chain and the biokinetics of radiocesium in humans. There is no significant correlation between the ground activity levels and the activity levels observed in the food which is consumed in the same area. The average internal dose in the first year after the Chernobyl accident was estimated to 0.110 ± 0.006 mSv and the external dose to 0.070 ± 0.007 mSv as an average for the whole country. 13 refs., 3 figs., 4 tabs

  4. Levels of external natural radiation and doses to population in Heilongjiang province

    International Nuclear Information System (INIS)

    Liang Yicheng; He Yongjiang; Wang Lu

    1985-01-01

    The external natural radiation level in Heilongjiang Province was measured by using China-made FD-71 scintillation radiometers and RSS-111 high pressure ionization chambers. The doses of external radiation to population were also calculated. The population-weighted average value of the absorbed dose rate from terrestrial γ-radiation was 7.2 x 10 -8 Gy.h -1 for outdoors, and 10.8 x 10 -8 Gy.h -1 for indoors. The population-weighted average absorbed dose rate in air from cosmic rays was 3.3 x 10 -8 Gy.h -1 . The annual population-weighted average effective dose equivalent and the annual collective effective dose equivalent from the environmental γ-radiation were 620 μSv and 20.1 x 10 3 man.Sv, respectively. The corresponding figures from cosmic rays were 260 μSv and 8.7 x 10 3 man.Sv, respectively

  5. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-01-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  6. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    Energy Technology Data Exchange (ETDEWEB)

    Morishima, Hiroshige; Koga, Taeko [Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-10-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  7. Total-dose hardness assurance for low earth orbit

    International Nuclear Information System (INIS)

    Maurer, R.H.; Suter, J.J.

    1987-01-01

    The Low Earth Orbit radiation environment has two significant characteristics that make laboratory simulation exposures difficult: (1) a low dose rate and (2) many cycles of low dose accumulation followed by dose-free annealing. Hardness assurance considerations for this environment are discussed and related to data from the testing of Advanced Low Power Schottky and High-speed CMOS devices

  8. Measurement and assessment of doses from external radiations required for revised radiation protection regulations

    International Nuclear Information System (INIS)

    Tsujimura, Norio; Kojima, Noboru; Hayashi, Naomi

    2001-01-01

    Radiation protection regulations based on the 1990 recommendations of ICRP have been revised and will take effect from Apr., 2001. The major changes concerning on the measurement and assessment of doses from external radiations are as follows. (1) Personal dose equivalent and ambient dose equivalent stated in ICRP Publication 74 are introduced as quantities to be measured with personal dosimeters and survey instruments, respectively. (2) For multiple dosimetry for workers, the compartment weighting factors used for a realistic assessment of effective dose are markedly changed. In advance of the introduction of the new radiation protection regulations, the impacts on workplace and personal monitoring for external radiations by these revisions were investigated. The following results were obtained. (1) A new ambient dose equivalent to neutrons is higher with a factor of 1.2 than the old one for moderated fission neutron spectra. Therefore, neutron dose equivalent monitors for workplace monitoring at MOX fuel for facilities should be recalibrated for measurement of the new ambient dose equivalent. (2) Annual effective doses of workers were estimated by applying new calibration factors to readings of personal dosimeters, worn by workers. Differences between effective doses and effective dose equivalents are small for workers engaged in the fabrication process of MOX fuel. (author)

  9. Measurement and assessment of doses from external radiations required for revised radiation protection regulations

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio; Kojima, Noboru; Hayashi, Naomi [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan)

    2001-06-01

    Radiation protection regulations based on the 1990 recommendations of ICRP have been revised and will take effect from Apr., 2001. The major changes concerning on the measurement and assessment of doses from external radiations are as follows. (1) Personal dose equivalent and ambient dose equivalent stated in ICRP Publication 74 are introduced as quantities to be measured with personal dosimeters and survey instruments, respectively. (2) For multiple dosimetry for workers, the compartment weighting factors used for a realistic assessment of effective dose are markedly changed. In advance of the introduction of the new radiation protection regulations, the impacts on workplace and personal monitoring for external radiations by these revisions were investigated. The following results were obtained. (1) A new ambient dose equivalent to neutrons is higher with a factor of 1.2 than the old one for moderated fission neutron spectra. Therefore, neutron dose equivalent monitors for workplace monitoring at MOX fuel for facilities should be recalibrated for measurement of the new ambient dose equivalent. (2) Annual effective doses of workers were estimated by applying new calibration factors to readings of personal dosimeters, worn by workers. Differences between effective doses and effective dose equivalents are small for workers engaged in the fabrication process of MOX fuel. (author)

  10. Dose estimation in embryo or fetus in external fields; Estimacion de dosis en embrion o feto

    Energy Technology Data Exchange (ETDEWEB)

    Gregori, Beatriz N [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina)

    2001-07-01

    The embryo or the fetus can be irradiated as result of radiological procedures of diagnosis of therapy in where the beam effects directly on the same one or in tissues or peripherical organs. Some authors have suggested that in the first stages of the pregnancy the dose in ovaries can be the good estimated of the dose in embryo or fetus. In advanced conditions of the development, probably also in the early stage, is more appropriated to specify the dose in the embryo or fetus equal of the uterus. The dose in the uterus is a good estimated so much for external irradiation as for radionuclides incorporation.

  11. NIRS external dose estimation system for Fukushima residents after the Fukushima Dai-ichi NPP accident

    Science.gov (United States)

    Akahane, Keiichi; Yonai, Shunsuke; Fukuda, Shigekazu; Miyahara, Nobuyuki; Yasuda, Hiroshi; Iwaoka, Kazuki; Matsumoto, Masaki; Fukumura, Akifumi; Akashi, Makoto

    2013-04-01

    The great east Japan earthquake and subsequent tsunamis caused Fukushima Dai-ichi Nuclear Power Plant (NPP) accident. National Institute of Radiological Sciences (NIRS) developed the external dose estimation system for Fukushima residents. The system is being used in the Fukushima health management survey. The doses can be obtained by superimposing the behavior data of the residents on the dose rate maps. For grasping the doses, 18 evacuation patterns of the residents were assumed by considering the actual evacuation information before using the survey data. The doses of the residents from the deliberate evacuation area were relatively higher than those from the area within 20 km radius. The estimated doses varied from around 1 to 6 mSv for the residents evacuated from the representative places in the deliberate evacuation area. The maximum dose in 18 evacuation patterns was estimated to be 19 mSv.

  12. Evaluation of GafChromic EBT prototype B for external beam dose verification

    International Nuclear Information System (INIS)

    Todorovic, M.; Fischer, M.; Cremers, F.; Thom, E.; Schmidt, R.

    2006-01-01

    The capability of the new GafChromic EBT prototype B for external beam dose verification is investigated in this paper. First the general characteristics of this film (dose response, postirradiation coloration, influence of calibration field size) were derived using a flat-bed scanner. In the dose range from 0.1 to 8 Gy, the sensitivity of the EBT prototype B film is ten times higher than the response of the GafChromic HS, which so far was the GafChromic film with the highest sensitivity. Compared with the Kodak EDR2 film, the response of the EBT is higher by a factor of 3 in the dose range from 0.1 to 8 Gy. The GafChromic EBT almost does not show a temporal growth of the optical density and there is no influence of the chosen calibration field size on the dose response curve obtained from this data. A MatLab program was written to evaluate the two-dimensional dose distributions from treatment planning systems and GafChromic EBT film measurements. Verification of external beam therapy (SRT, IMRT) using the above-mentioned approach resulted in very small differences between the planned and the applied dose. The GafChromic EBT prototype B together with the flat-bed scanner and MatLab is a successful approach for making the advantages of the GafChromic films applicable for verification of external beam therapy

  13. External radiation survey and dose predictions for Rongelap, Utirik, Rongerik, Ailuk, and Wotje Atolls

    International Nuclear Information System (INIS)

    Greenhouse, N.A.; Miltenberger, R.P.

    1977-01-01

    External radiation measurements were made at several atolls in the northern Marshall Islands, which are known or suspected to have been the recipients of tropospheric fallout during the Pacific Testing Programs. Sufficient data were available to ascertain realistic dose predictions for the inhabitants of Rongelap and Utirik Atolls where the 30 year integral doses from external sources exclusive of background radiation were 0.65 and 0.06 rem respectively. These estimates are based on realistic life-style models based on observations of each atoll community. Ailuk and Wotje Atolls were found to be represenatives of regional background radiation levels

  14. Doses of external exposure in Jordan house due to gamma-emitting natural radionuclides in building materials.

    Science.gov (United States)

    Al-Jundi, J; Ulanovsky, A; Pröhl, G

    2009-10-01

    The use of building materials containing naturally occurring radionuclides as (40)K, (232)Th, and (238)U and their progeny results in external exposures of the residents of such buildings. In the present study, indoor dose rates for a typical Jordan concrete room are calculated using Monte Carlo method. Uniform chemical composition of the walls, floor and ceiling as well as uniform mass concentrations of the radionuclides in walls, floor and ceiling are assumed. Using activity concentrations of natural radionuclides typical for the Jordan houses and assuming them to be in secular equilibrium with their progeny, the maximum annual effective doses are estimated to be 0.16, 0.12 and 0.22 mSv a(-1) for (40)K, (232)Th- and (238)U-series, respectively. In a total, the maximum annual effective indoor dose due to external gamma-radiation is 0.50 mSv a(-1). Additionally, organ dose coefficients are calculated for all organs considered in ICRP Publication 74. Breast, skin and eye lenses have the maximum equivalent dose rate values due to indoor exposures caused by the natural radionuclides, while equivalent dose rates for uterus, colon (LLI) and small intestine are found to be the smallest. More specifically, organ dose rates (nSv a(-1)per Bq kg(-1)) vary from 0.044 to 0.060 for (40)K, from 0.44 to 0.60 for radionuclides from (238)U-series and from 0.60 to 0.81 for radionuclides from (232)Th-series. The obtained organ and effective dose conversion coefficients can be conveniently used in practical dose assessment tasks for the rooms of similar geometry and varying activity concentrations and local-specific occupancy factors.

  15. Effects of total dose of ionizing radiation on integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marcilei A.G.; Cirne, K.H.; Gimenez, S.; Santos, R.B.B. [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil); Added, N.; Barbosa, M.D.L.; Medina, N.H.; Tabacniks, M.H. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Lima, J.A. de; Seixas Junior, L.E.; Melo, W. [Centro de Tecnologia da Informacao Paulo Archer, Sao Paulo, SP (Brazil)

    2011-07-01

    Full text: The study of ionizing radiation effects on materials used in electronic devices is of great relevance for the progress of global technological development and, particularly, it is a necessity in some strategic areas in Brazil. Electronic circuits are strongly influenced by radiation and the need for IC's featuring radiation hardness is largely growing to meet the stringent environment in space electronics. On the other hand, aerospace agencies are encouraging both scientific community and semiconductors industry to develop hardened-by-design components using standard manufacturing processes to achieve maximum performance, while significantly reducing costs. To understand the physical phenomena responsible for changes in devices exposed to ionizing radiation several kinds of radiation should then be considered, among them alpha particles, protons, gamma and X-rays. Radiation effects on the integrated circuits are usually divided into two categories: total ionizing dose (TID), a cumulative dose that shifts the threshold voltage and increases transistor's off-state current; single events effects (SEE), a transient effect which can deposit charge directly into the device and disturb the properties of electronic circuits. TID is one of the most common effects and may generate degradation in some parameters of the CMOS electronic devices, such as the threshold voltage oscillation, increase of the sub-threshold slope and increase of the off-state current. The effects of ionizing radiation are the creation of electron-hole pairs in the oxide layer changing operation mode parameters of the electronic device. Indirectly, there will be also changes in the device due to the formation of secondary electrons from the interaction of electromagnetic radiation with the material, since the charge carriers can be trapped both in the oxide layer and in the interface with the oxide. In this work we have investigated the behavior of MOSFET devices fabricated with

  16. Dose conversion coefficients calculated using a series of adult Japanese voxel phantoms against external photon exposure

    International Nuclear Information System (INIS)

    Sato, Kaoru; Endo, Akira; Saito, Kimiaki

    2008-10-01

    This report presents a complete set of conversion coefficients of organ doses and effective doses calculated for external photon exposure using five Japanese adult voxel phantoms developed at the Japan Atomic Energy Agency (JAEA). At the JAEA, high-resolution Japanese voxel phantoms have been developed to clarify the variation of organ doses due to the anatomical characteristics of Japanese, and three male phantoms (JM, JM2 and Otoko) and two female phantoms (JF and Onago) have been constructed up to now. The conversion coefficients of organ doses and effective doses for the five voxel phantoms have been calculated for six kinds of idealized irradiation geometries from monoenergetic photons ranging from 0.01 to 10 MeV using EGS4, a Monte Carlo code for the simulation of coupled electron-photon transport. The dose conversion coefficients are given as absorbed dose and effective dose per unit air-kerma free-in-air, and are presented in tables and figures. The calculated dose conversion coefficients are compared with those of voxel phantoms based on the Caucasian and the recommended values in ICRP74 in order to discuss (1) variation of organ dose due to the body size and individual anatomy, such as position and shape of organs, and (2) effect of posture on organ doses. The present report provides valuable data to study the influence of the body characteristics of Japanese upon the organ doses and to discuss developing reference Japanese and Asian phantoms. (author)

  17. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    International Nuclear Information System (INIS)

    Fritz, T.E.; Norris, W.P.; Tolle, D.V.; Seed, T.M.; Poole, C.M.; Lombard, L.S.; Doyle, D.E.

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to 60 Co γ rays in a specially constructed facility. The exposure rates were either 5, 10, 17, or 35 R/day, and the exposures were terminated at either 600, 1400, 2000, or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD 50 for γ-ray exposures given at a number of exposure rates. They also allow comparison of the relative importance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD 50 for the beagle increases from 258 rad delivered at 15 R/minute to approximately 3000 rad at 10 R/day. Over this entire range, the LD 50 is dependent upon hematopoietic damage. At 5 R/day and less, no meaningful LD 50 can be determined; there is nearly normal continued hematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in other organ systems. Although the experiment is not complete, interim data allow several important conclusions. Terminated exposures, while not as effective as radiation continued until death, can produce myelogenous leukemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates are more damaging than higher rates on the basis of the rate and degree of hematological recovery that occurs after termination of irradiation. Thus, the rate of hematologic depression, the nadir of the depression, and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the former two are directly related to exposure rate

  18. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    International Nuclear Information System (INIS)

    Fritz, T.E.; Norris, W.P.; Tolle, D.V.; Seed, T.M.; Poole, C.M.; Lombard, L.S.; Doyle, D.E.

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to 60 Co gamma rays in a specially constructed facility. The exposure rates were 5, 19, 17 or 35 R/day, and the exposures were terminated at 600, 1400, 2000 or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD 50 for gamma-ray exposures given at a number of exposure rates. They also allow comparison of the relativeimportance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD 50 for the beagle increases from 344 R (258 rads) delivered at 15 R/minute to approximately 4000 R (approximately 3000 rads) at 10 R/day. Over this entire range, the LD 50 is dependent upon haematopoietic damage. At 5 R/day and less, no definitive LD 50 can be determined; there is nearly normal continued haematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in the organ systems. Although the experiment is not complete, interim data allow serveral important conclusions. Terminated exposures, while not as effective as irradiation continued until death, can produce myelogenous leukaemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates appear more damaging than higher rates on the basis of the rate and degree of haematological recovery that occurs after termination of irradiation. Thus, the rate of haematologic depression, the nadir of the depression and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the first two are directly related to exposure rate. ( author)

  19. New Insights into Fully-Depleted SOI Transistor Response During Total Dose Irradiation

    International Nuclear Information System (INIS)

    Burns, J.A.; Dodd, P.E.; Keast, C.L.; Schwank, J.R.; Shaneyfelt, M.R.; Wyatt, P.W.

    1999-01-01

    Worst-case bias configuration for total-dose testing fully-depleted SOI transistors was found to be process dependent. No evidence was found for total-dose induced snap back. These results have implications for hardness assurance testing

  20. Measurement of the natural radioactivity in building materials used in Ankara and assessment of external doses.

    Science.gov (United States)

    Turhan, S; Baykan, U N; Sen, K

    2008-03-01

    A total of 183 samples of 20 different commonly used structural and covering building materials were collected from housing and other building construction sites and from suppliers in Ankara to measure the natural radioactivity due to the presence of (226)Ra, (232)Th and (40)K. The measurements were carried out using gamma-ray spectrometry with two HPGe detectors. The specific activities of the different building materials studied varied from 0.5 +/- 0.1 to 144.9 +/- 4.9 Bq kg(-1), 0.6 +/- 0.2 to 169.9 +/- 6.6 Bq kg(-1) and 2.0 +/- 0.1 to 1792.3 +/- 60.8 Bq kg(-1) for (226)Ra, (232)Th and (40)K, respectively. The results show that the lowest mean values of the specific activity of (226)Ra, (232)Th and (40)K are 0.8 +/- 0.5, 0.9 +/- 0.4 and 4.1 +/- 1.4 Bq kg(-1), respectively, measured in travertine tile while the highest mean values of the specific activity of the same radionuclides are 78.5 +/- 18.1 (ceramic wall tile), 77.4 +/- 53.0 (granite tile) and 923.4 +/- 161.0 (white brick), respectively. The radium equivalent activity (Ra(eq)), the gamma-index, the indoor absorbed dose rate and the corresponding annual effective dose were evaluated to assess the potential radiological hazard associated with these building materials. The mean values of the gamma-index and the estimated annual effective dose due to external gamma radiation inside the room for structural building materials ranged from 0.15 to 0.89 and 0.2 to 1.1 mSv, respectively. Applying criteria recently recommended for building materials in the literature, four materials meet the exemption annual dose criterion of 0.3 mSv, five materials meet the annual dose limit of 1 mSv and only one material slightly exceeds this limit. The mean values of the gamma-index for all building materials were lower than the upper limit of 1.

  1. Calculation of age-dependent effective doses for external exposure using the MCNP code

    International Nuclear Information System (INIS)

    Hung, Tran Van

    2013-01-01

    Age-dependent effective dose for external exposure to photons uniformly distributed in air were calculated. Firstly, organ doses were calculated with a series of age-specific MIRD-5 type phantoms using the Monte Carlo code MCNP. The calculations were performed for mono-energetic photon sources with source energies from 10 keV to 5 MeV and for phantoms of newborn, 1, 5, 10, and 15 years-old and adult. Then, the effective doses to the different age-phantoms from the mono-energetic photon sources were estimated based on the obtained organ doses. From the calculated results, it is shown that the effective doses depend on the body size; the effective doses in younger phantoms are higher than those in the older phantoms, especially below 100 keV. (orig.)

  2. Calculation of age-dependent effective doses for external exposure using the MCNP code

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Tran Van [Research and Development Center for Radiation Technology, ThuDuc, HoChiMinh City (VT)

    2013-07-15

    Age-dependent effective dose for external exposure to photons uniformly distributed in air were calculated. Firstly, organ doses were calculated with a series of age-specific MIRD-5 type phantoms using the Monte Carlo code MCNP. The calculations were performed for mono-energetic photon sources with source energies from 10 keV to 5 MeV and for phantoms of newborn, 1, 5, 10, and 15 years-old and adult. Then, the effective doses to the different age-phantoms from the mono-energetic photon sources were estimated based on the obtained organ doses. From the calculated results, it is shown that the effective doses depend on the body size; the effective doses in younger phantoms are higher than those in the older phantoms, especially below 100 keV. (orig.)

  3. Summary of recorded external radiation doses for Hanford workers 1944--1989

    International Nuclear Information System (INIS)

    Buschbom, R.L.; Gilbert, E.S.

    1993-10-01

    This report summarizes recorded external radiation doses for the years 1944 through 1989 received by operations workers who were included in the Hanford Mortality Study. This study population includes all operations workers who were initially employed at the Hanford site from 1944 through 1978. Descriptive summaries are provided for both annual and cumulative whole body penetrating doses. Although the main emphasis of the report is on recorded whole body penetrating dose, summary tables are included for the components of whole body penetrating dose, non-penetrating dose, and extremity dose. Summaries are provided for the entire study population and for subgroups of the population defined by sex, age, number of years since first monitoring, and socioeconomic groups

  4. Outlines of ICRP publication 74 and new dose conversion coefficients for external radiation

    International Nuclear Information System (INIS)

    Yamaguchi, Yasuhiro

    1998-01-01

    Combined task group of ICRP and ICRU reported the ICRP Publication 74 (1996) which is a summary report of their collection, analysis and evaluation of many data and dose conversion coefficients. Concerning the new coefficients, the author described this review as follows: History until Publication 74. Doses recommended at present: for protection quantity, the mean absorption dose of organ and tissue, equivalent dose and effective dose and for operational quantity, the ambient dose equivalent, directional dose equivalent and individual dose equivalent. Changes which can have an influence on the dose evaluation; introduction of radiation weighting factor (WR), changing of tissue weighting factor (WR), changing of the equation for Q-L relation and updating of physical data. New dose conversion coefficients; for photon, neutron and electron. Comparison of new and present coefficients; concerning the quality factor Q, particularly for neutron Q. New relations of protection and operational quantities; for field and individual monitoring. General conclusion of Publication 74. The Publication gives a certain direction for problems in evaluation of external exposure dose which have been discussed since the ICRP Fundamental Recommendation 1990 was issued. However, there still remain many problems especially in validity of the WR and of equation for Q-L relation. (K.H.)

  5. Dose compensation of the total body irradiation therapy

    International Nuclear Information System (INIS)

    Lin, J.-P.; Chu, T.-C.; Liu, M.-T.

    2001-01-01

    The aim of the study is to improve dose uniformity in the body by the compensator-rice and to decrease the dose to the lung by the partial lung block. Rando phantom supine was set up to treat bilateral fields with a 15 MV linear accelerator at 415 cm treatment distance. The experimental procedure included three parts. The first part was the bilateral irradiation without rice compensator, and the second part was with rice compensator. In the third part, rice compensator and partial lung block were both used. The results of thermoluminescent dosimeters measurements indicated that without rice compensator the dose was non-uniform. Contrarily, the average dose homogeneity with rice compensator was measured within ±5%, except for the thorax region. Partial lung block can reduce the dose which the lung received. This is a simple method to improve the dose homogeneity and to reduce the lung dose received. The compensator-rice is cheap, and acrylic boxes are easy to obtain. Therefore, this technique is suitable for more studies

  6. Reduction of external dose in a wet-contaminated housing area in the Bryansk region, Russia

    DEFF Research Database (Denmark)

    Roed, Jørn; Andersson, Kasper Grann; Barkovsky, A.N.

    2006-01-01

    An investigation of the feasibility of reducing the external dose rate in a recreational housing area located between the settlements of Guta and Muravinka, Bryansk Region, Russia, which had been contaminated by the Chernobyl accident more than a decade earlier was made. Removal of contaminated...

  7. Changes in Energy Cost and Total External Work of Muscles in Elite Race Walkers Walking at Different Speeds

    Directory of Open Access Journals (Sweden)

    Chwała Wiesław

    2014-12-01

    Full Text Available The aim of the study was to assess energy cost and total external work (total energy depending on the speed of race walking. Another objective was to determine the contribution of external work to total energy cost of walking at technical, threshold and racing speed in elite competitive race walkers.

  8. Monitoring and assessment of individual doses of occupationally exposed workers due to external radiation

    International Nuclear Information System (INIS)

    Kitaw, S. T.

    2015-05-01

    Exposure to external radiation occurs in many occupations. Any exposure to ionizing radiation has the tendency to change the biochemical make-up of the human body which may result in biological health effects of ionizing radiation. This study reviews the monitoring and assessment of external radiation doses in industrial radiography using thermoluminescence and direct reading dosimeters. Poor handling procedures such as inadequate engineering control of equipment, safety culture, management, and inadequate assessment and monitoring of doses are the causes of most of the reported cases of exposure to external radiation in industrial radiography. Occupational exposure data in industrial radiography from UNSCEAR report 2008 was discussed and recommendations were made to regulatory authorities, operating organizations and radiographers. (au)

  9. Tolerance doses of cutaneous and mucosal tissues in ring-necked parakeets (Psittacula krameri) for external beam megavoltage radiation.

    Science.gov (United States)

    Barron, Heather W; Roberts, Royce E; Latimer, Kenneth S; Hernandez-Divers, Stephen; Northrup, Nicole C

    2009-03-01

    Currently used dosages for external-beam megavoltage radiation therapy in birds have been extrapolated from mammalian patients and often appear to provide inadequate doses of radiation for effective tumor control. To determine the tolerance doses of cutaneous and mucosal tissues of normal birds in order to provide more effective radiation treatment for tumors that have been shown to be radiation responsive in other species, ingluvial mucosa and the skin over the ingluvies of 9 ring-necked parakeets (Psittacula krameri) were irradiated in 4-Gy fractions to a total dose of either 48, 60, or 72 Gy using an isocentric cobalt-60 teletherapy unit. Minimal radiation-induced epidermal changes were present in the high-dose group histologically. Neither dose-related acute nor chronic radiation effects could be detected in any group grossly in cutaneous or mucosal tissue over a 9-month period. Radiation doses of 72 Gy in 4-Gy fractions were well tolerated in the small number of ring-necked parakeets in this initial tolerance dose study.

  10. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Morishima, Hiroshige [Kinki Univ., Atomic Energy Research Institute, Osaka (Japan); Tatsumi, Kusuo [Kinki Univ., Life Science Research Institute, Osaka (Japan); Nakai, Sayaka; Sugahara, Tsutomu [Health Research Foundation, Kyoto (Japan); Yuan Yongling [Labor Hygiene Institute of Hunan Prov. (China); Wei Luxin [Laboratory of Industorial Hygiene, Ministry of Health (China)

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: (1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. (2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  11. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    International Nuclear Information System (INIS)

    Koga, Taeko; Morishima, Hiroshige; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: 1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. 2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  12. The Study of External Radiation Dose for Radiation Worker at PRSG-BATAN Serpong

    International Nuclear Information System (INIS)

    Sunarningsih; Mashudi; A Lilik W; Yosep S

    2012-01-01

    The study of External radiation dose for radiation worker at PRSG-BATAN Serpong has been carried out. The sample is taken from the System Reactor division (BSR), Operation Reactor division, (BOR) Safety division UPN, UJM and head of PRSG by setting Thermoluminescence Dosemeter (TLD) on the chest, then is detected by a tool TLD reader model 6600. The aim of this study is to evaluate the occupational exposure dose that has been accepted by the radiation worker for the last five years. The result in average doses at BSR is 0,99 mSv, BOR is 3,27 mSv, at BK is 0,69 mSv and UPN + UJM + head of PRSG is 0,03 mSv. The result highest doses at BSR is 6,58 mSv, BOR is 28,94 mSv, BK is 4,24 mSv, and UPN UJM Head of PRSG is 0,52 mSv. Dose interval radiation worker at PRSG BATAN ttd - 28,98 mSv. To overall the external personal dose acceptant for radiation worker at PRSG BATAN one below maximum permissible dose acceptant that allowed by BAPETEN, that is 20 mSv in average every year during five years. (author)

  13. Measurement and comparison of individual external doses of high-school students living in Japan, France, Poland and Belarus—the ‘D-shuttle’ project—

    International Nuclear Information System (INIS)

    Adachi, N; Adamovitch, V; Adjovi, Y; Antonietti, H; Arkoun, G; Blanchard, M; Aida, K; Akamatsu, H; Akiyama, S; Akli, A; Bernard, E; Ando, A; Andrault, T; Ayrault, D; Anzai, S; Avenoso, C; Bernardini, L; Berthet, E; Banasiewicz, M; Banaśkiewicz, M

    2016-01-01

    Twelve high schools in Japan (of which six are in Fukushima Prefecture), four in France, eight in Poland and two in Belarus cooperated in the measurement and comparison of individual external doses in 2014. In total 216 high-school students and teachers participated in the study. Each participant wore an electronic personal dosimeter ‘D-shuttle’ for two weeks, and kept a journal of his/her whereabouts and activities. The distributions of annual external doses estimated for each region overlap with each other, demonstrating that the personal external individual doses in locations where residence is currently allowed in Fukushima Prefecture and in Belarus are well within the range of estimated annual doses due to the terrestrial background radiation level of other regions/countries. (paper)

  14. Procedure on reconstruction of external dose to evacuees at Chernobyl accident

    International Nuclear Information System (INIS)

    Nakajima, T.; Likhtariov, I.; Repin, V.S.

    1992-01-01

    An external dose estimation on the Chernobyl accident was carried out using sugar left in two houses at Pripyat-city from before the accident. The external dose to the people evacuated from Pripyat-city after the Chernobyl accident has been estimated using both a data from the sugar-electron spin resonance (ESR) dosimeter and information on the type of buildings and the exposure rates there. In this work, the procedure of the dose estimation for the evacuees in Pripyat-city be reported. Furthermore, the sugar-ESR method will be discussed. The present result good agree with one reported from USSR to IAEA. It has been certified that small crystalline sugar such as granulated sugar is one of the most useful dosimeter in the emergency for the public. (author)

  15. Laboratory Bioaccumulation, Depuration And Total Dose Rate Of Waterborne Th-232 In Freshwater Fish Of Anabas Testudineus

    International Nuclear Information System (INIS)

    Zal U'yun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2014-01-01

    Preliminary results on the study of bioaccumulation, depuration and total dose rate of Th-232 in the whole body of Anabas testudineus are presented. The objective of this study was to evaluate the effect of Th-232 concentration activity on the laboratory bioaccumulation, depuration and total dose rate in Anabas testudineus. Anabas testudineus adults were exposed to different waterborne Th-232 levels: 0 BqL -1 (control), 50 BqL -1 and 100 BqL -1 for 30 day (uptake phase), followed by exposure to radionuclide-free water for 30 days (loss phase). Radionuclide concentration ratios between the whole body levels and water levels, percentage of Th-232 remaining in fish were calculated and total dose rates using ERICA Assessment Tool were also estimated. The results showed the increase of waterborne Th-232 concentration corresponded to a progressive increase of Th accumulation and total dose rate (internal and external) in the whole body of Anabas testudineus. Considering the ERICA dose rate screening value of 10 μGyh -1 , the findings can be concluded the estimated of total dose rate (< 5 μGyh -1 ) in Anabas testudineus is in order of small magnitude. Nevertheless, these preliminary results showed that the Anabas testudineus has a potential to accumulate thorium. (author)

  16. Assessment of uncertainties of external dose estimation after the Chernobyl accident

    International Nuclear Information System (INIS)

    Kruk, Julianna

    2008-01-01

    Full text: In the remote period of time after the Chernobyl accident the estimation of an external exposure with using of direct dose rate measurements or individual monitoring of inhabitants is rationally only for settlements where the preliminary estimation makes the range equal or greater 1.0 mSv per year. For inhabitancies of settlements where the preliminary estimation makes the range less 1.0 mSv per year the external dose is correctly to estimate by calculation. For the last cases the uncertainty should be assessed. The most accessible initial parameter for calculation of a dose of an external exposure is the average ground deposition of Cs-137 for the settlements. The character of density distribution of Cs-137 deposition in an area of one settlement is well enough studied. The best agreement of distribution of this parameter is reached with log-normal distribution practically for all settlements of the investigated territories with factor of a variation 0.3-0.6 and the standard geometrical deviation lying within the limits of 1.4-1.7. The dose factors which correspond to the structure of an available housing of settlement (type of apartment houses: wooden, stone, multi-storey) and age structure of the population are bring the main contribution into uncertainty of the external dose estimation. The situations with a different level of known information have been considered for the estimation of influence of those parameters on the general uncertainty. Thus the estimation of the uncertainty of the external dose was done for two variant: optimistic and pessimistic. In the optimistic case the estimation of external doses will be spent for specific settlement with known structure of housing and according to a known share of the living population in houses of the certain type. In that case, variability value dose factor will be limited to the chosen type of a residential building (for example - the one-storied wooden house), and a share of the living population

  17. Northern Marshall Islands radiological survey: terrestrial food chain and total doses

    International Nuclear Information System (INIS)

    Robison, W.L.; Mount, M.E.; Phillips, W.A.; Conrado, C.A.; Stuart, M.L.; Stoker, C.E.

    1982-01-01

    A radiological survey was conducted from September through November of 1978 to assess the concentrations of persistent manmade radionuclides in the terrestrial and marine environments of 11 atolls and 2 islands in the Northern Marshall Islands. The survey consisted mainly of an aerial radiological reconnaissance to map the external gamma-ray exposure rates over the islands of each atoll. The logistical support for the entire survey was designed to accommodate this operation. As a secondary phase of the survey, shore parties collected appropriate terrestrial and marine samples to assess the radiological dose from pertinent food chains to those individuals residing on the atolls, who may in the future reside on some of the presently uninhabited atolls, or who collect food from these atolls. Over 5000 terrestrial and marine samples were collected for radionuclide analysis from 76 different islands. Soils, vegetation, indigenous animals, and cistern water and groundwater were collected from the islands. Reef and pelagic fish, clams, lagoon water, and sediments were obtained from the lagoons. The concentration data for 90 Sr, 137 Cs, 238 Pu, 239 240 Pu, and 241 Am in terrestrial food crops, fowl, and animals collected at the atolls or islands are summarized. An assessment of the total dose from the major exposure pathways including external gamma, terrestrial food chain including food products and drinking water, marine food chain, and inhalation is provided. Radiological doses at each atoll or island are calculated from the average radionuclide concentrations in the terrestrial foods, marine foods, etc. assuming the average daily intake for each food item

  18. Total dose and dose rate radiation characterization of EPI-CMOS radiation hardened memory and microprocessor devices

    International Nuclear Information System (INIS)

    Gingerich, B.L.; Hermsen, J.M.; Lee, J.C.; Schroeder, J.E.

    1984-01-01

    The process, circuit discription, and total dose radiation characteristics are presented for two second generation hardened 4K EPI-CMOS RAMs and a first generation 80C85 microprocessor. Total dose radiation performance is presented to 10M rad-Si and effects of biasing and operating conditions are discussed. The dose rate sensitivity of the 4K RAMs is also presented along with single event upset (SEU) test data

  19. Measurements of individual doses from external radiation in the Brjansk region of the Russian republic of the USSR

    International Nuclear Information System (INIS)

    Wallstroem, E.; Woehni, T.

    1991-01-01

    Individual doses from external photon radiation to various occupational groups in three different villages in the Brjansk region of the Russian republic of the USSR have been measured by individual TL-dosemeters. A total of 86 persons were monitored for a period of 10 days in September 1990, from which 83 dosemeters were returned. The villages had different levels of deposition, but they all belonged to the ''strictly controlled zone'', i.e. deposition levels 555 to 1480 kBq/m 2 (15 to 40 Ci/km 2 ). The results show individual effective dose equivalents during one month in the range 80 to 1000 μSv. Schoolchildren received the lowest doses, and different groups of fields workers the highest. Estimated mean annual effective dose equivalents ranged from 2.0 mSv to 4.6 mSv for the different occupational groups and types of dwellings. Monthly mean effective dose equivalents relative to the reported mean deposition of Cs-137 ranged from 110 (in-door workers in stone houses) to 290 μSv per MBq/m 2 (out-door workers in wooden houses). The reported results are lower than theorectical estimates based on the reported level on contamination. The ratio of the mean effective dose equivalent for persons living in wooden and stone houses ranged from 1.4 to 2.6 for the various villages and occupational groups. 21 refs., 5 figs., 9 tabs

  20. Temporal reduction of the external gamma dose rate due to 137Cs mobility in sandy beaches

    International Nuclear Information System (INIS)

    Rizzotto, M.; Toso, J.; Velasco, H.; Belli, M.; Sansone, U.

    2009-01-01

    In the present paper the contribution to the external gamma dose rate due o 137 Cs in soil as a function of time is presented. Sampling sites were elected along the Calabria and Basilicata Regions coastal beaches (southern art of Italy) to assess the external gamma dose rate in air, 1 m above the round level. A convection-dispersion model, with constant parameters was sed to approximate the radiocesium soil vertical migration. The model was calibrated using the initial 137 Cs activity deposition in this region Chernobyl fallout) and 137 Cs activity concentration down the soil profile, measured 10 years later. The dispersion coefficient and the advection velocity values, were respectively: 2.17 cm 2 y -1 and 0.32 cm -1 . The Radionuclide Software Package (RSP), which uses a Monte Carlo simulation code, was used to determine the primary 137 Cs gamma dose contribution in air 1 m above the ground surface. The resulting 137 Cs external dose rate ranged from 0.42 nGy h -1 in 1986, to 0.05 nGy h -1 in 007. (author)

  1. Estimated dose rates to members of the public from external exposure to patients with {sup 131}I thyroid treatment

    Energy Technology Data Exchange (ETDEWEB)

    Dewji, S., E-mail: dewjisa@ornl.gov; Bellamy, M.; Leggett, R.; Eckerman, K. [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS-6335, Oak Ridge, Tennessee 37831 (United States); Hertel, N. [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS-6335, Oak Ridge, Tennessee 37831 and Georgia Institute of Technology, 770 State Street, Atlanta, Georgia 30332-0745 (United States); Sherbini, S.; Saba, M. [United States Nuclear Regulatory Commission, Washington, DC 20555-0001 (United States)

    2015-04-15

    Purpose: Estimated dose rates that may result from exposure to patients who had been administered iodine-131 ({sup 131}I) as part of medical therapy were calculated. These effective dose rate estimates were compared with simplified assumptions under United States Nuclear Regulatory Commission Regulatory Guide 8.39, which does not consider body tissue attenuation nor time-dependent redistribution and excretion of the administered {sup 131}I. Methods: Dose rates were estimated for members of the public potentially exposed to external irradiation from patients recently treated with {sup 131}I. Tissue attenuation and iodine biokinetics were considered in the patient in a larger comprehensive effort to improve external dose rate estimates. The external dose rate estimates are based on Monte Carlo simulations using the Phantom with Movable Arms and Legs (PIMAL), previously developed by Oak Ridge National Laboratory and the United States Nuclear Regulatory Commission. PIMAL was employed to model the relative positions of the {sup 131}I patient and members of the public in three exposure scenarios: (1) traveling on a bus in a total of six seated or standing permutations, (2) two nursing home cases where a caregiver is seated at 30 cm from the patient’s bedside and a nursing home resident seated 250 cm away from the patient in an adjacent bed, and (3) two hotel cases where the patient and a guest are in adjacent rooms with beds on opposite sides of the common wall, with the patient and guest both in bed and either seated back-to-back or lying head to head. The biokinetic model predictions of the retention and distribution of {sup 131}I in the patient assumed a single voiding of urinary bladder contents that occurred during the trip at 2, 4, or 8 h after {sup 131}I administration for the public transportation cases, continuous first-order voiding for the nursing home cases, and regular periodic voiding at 4, 8, or 12 h after administration for the hotel room cases. Organ

  2. Estimated dose rates to members of the public from external exposure to patients with 131I thyroid treatment

    International Nuclear Information System (INIS)

    Dewji, S.; Bellamy, M.; Leggett, R.; Eckerman, K.; Hertel, N.; Sherbini, S.; Saba, M.

    2015-01-01

    Purpose: Estimated dose rates that may result from exposure to patients who had been administered iodine-131 ( 131 I) as part of medical therapy were calculated. These effective dose rate estimates were compared with simplified assumptions under United States Nuclear Regulatory Commission Regulatory Guide 8.39, which does not consider body tissue attenuation nor time-dependent redistribution and excretion of the administered 131 I. Methods: Dose rates were estimated for members of the public potentially exposed to external irradiation from patients recently treated with 131 I. Tissue attenuation and iodine biokinetics were considered in the patient in a larger comprehensive effort to improve external dose rate estimates. The external dose rate estimates are based on Monte Carlo simulations using the Phantom with Movable Arms and Legs (PIMAL), previously developed by Oak Ridge National Laboratory and the United States Nuclear Regulatory Commission. PIMAL was employed to model the relative positions of the 131 I patient and members of the public in three exposure scenarios: (1) traveling on a bus in a total of six seated or standing permutations, (2) two nursing home cases where a caregiver is seated at 30 cm from the patient’s bedside and a nursing home resident seated 250 cm away from the patient in an adjacent bed, and (3) two hotel cases where the patient and a guest are in adjacent rooms with beds on opposite sides of the common wall, with the patient and guest both in bed and either seated back-to-back or lying head to head. The biokinetic model predictions of the retention and distribution of 131 I in the patient assumed a single voiding of urinary bladder contents that occurred during the trip at 2, 4, or 8 h after 131 I administration for the public transportation cases, continuous first-order voiding for the nursing home cases, and regular periodic voiding at 4, 8, or 12 h after administration for the hotel room cases. Organ specific activities of 131 I

  3. Evaluation of accelerated test parameters for CMOS IC total dose hardness prediction

    International Nuclear Information System (INIS)

    Sogoyan, A.V.; Nikiforov, A.Y.; Chumakov, A.I.

    1999-01-01

    The approach to accelerated test parameters evaluation is presented in order to predict CMOS IC total dose behavior in variable dose-rate environment. The technique is based on the analytical model of MOSFET parameters total dose degradation. The simple way to estimate model parameter is proposed using IC's input-output MOSFET radiation test results. (authors)

  4. Peripheral photon and neutron doses from prostate cancer external beam irradiation.

    Science.gov (United States)

    Bezak, Eva; Takam, Rundgham; Marcu, Loredana G

    2015-12-01

    Peripheral photon and neutron doses from external beam radiotherapy (EBRT) are associated with increased risk of carcinogenesis in the out-of-field organs; thus, dose estimations of secondary radiation are imperative. Peripheral photon and neutron doses from EBRT of prostate carcinoma were measured in Rando phantom. (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescence dosemeters (TLDs) were inserted in slices of a Rando phantom followed by exposure to 80 Gy with 18-MV photon four-field 3D-CRT technique. The TLDs were calibrated using 6- and 18-MV X-ray beam. Neutron dose equivalents measured with CR-39 etch-track detectors were used to derive readout-to-neutron dose conversion factor for (6)LiF:Mg,Cu,P TLDs. Average neutron dose equivalents per 1 Gy of isocentre dose were 3.8±0.9 mSv Gy(-1) for thyroid and 7.0±5.4 mSv Gy(-1) for colon. For photons, the average dose equivalents per 1 Gy of isocentre dose were 0.2±0.1 mSv Gy(-1) for thyroid and 8.1±9.7 mSv Gy(-1) for colon. Paired (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P TLDs can be used to measure photon and neutron doses simultaneously. Organs in close proximity to target received larger doses from photons than those from neutrons whereas distally located organs received higher neutron versus photon dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Determination of dose received by bladder and rectum in external cervical irradiation

    International Nuclear Information System (INIS)

    Omer, Mohamed Ahmed Ali

    2001-12-01

    The cervical carcinoma is the common type of malignant tumor among sudanese females during the last years. The conventional external irradiation therapy is the common model of treatment for cervical carcinoma in (RICK). The irradiation of such cases implemented via four fields (box technique), two anterior and posterior and two lateral opposed fields, as central dose calculation, giving a dose of 5000 c Gy fractionated into 25 to 30 fractions. The parameter of the fields lie at the promontory of the sacral cephalic and at the obturators foramen caudally and laterally at the bony pelvic by one centimeter. The aim of the research is to determine the dose received by the rectum and bladder (critical organs), out of central dose calculation versus off axis dose calculation to (Day's method). The data obtained by using simulator and radiation oncological computerized system (Rocs). The results are analyzed by using statistical processing for social science program (SPSS) that shows the mean dose received by the bladder is 3821 cGy, due to central dose calculation that accompanied by an un-optimum encompassment of treatment line and 4210.6 c Gy. due to Off Axis Dose calculation dose 3324.4 c Gy and 3712.1 c Gy due to central dose calculation. The increment of dose received by the rectum and the bladder is due to utilizing of wider width of the filed size for lateral irradiation. To score the aim of International Atomic Energy Agency (IAEA) and (ALARA) principle A s Low As As Reasonable Available , we have to use the simulator to obtain the anatomical structures on the contour, or will be better to use CT. Scan for calculation of dose at the side of interest. (Author)

  6. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  7. Calculating external doses from contaminated soil with the computer model SOILD

    International Nuclear Information System (INIS)

    Chen, Y.; LePoire, D.; Yu, C.

    1991-01-01

    The SOILD computer model was developed for calculating the effective dose equivalent from external exposure to distributed gamma sources in soil. It is designed to assess external doses under various exposure scenarios that may be encountered in environmental restoration programs. The model's four major functional features address (a) dose versus source depth in soil, (b) shielding of clean cover soil, (c) area of contamination, and (d) nonuniform distribution of sources. The model can also adjust doses when there are variations in soil densities for both source and cover soils. It is supported by a data base of ∼500 radionuclides. A sample calculation was performed by SOILD to determine the effective dose equivalent for a uniform source distribution in soil. The soil density was assumed to be 1.6 g/cm 3 , and the source strength was assumed to be 1 pCi/cm 3 . The following radionuclides were studied: 60 C, 131 I, 137+D Cs, 238+D U, and 226+D Ra ('+D' denotes the parent nuclide and daughters)

  8. External exposure doses due to gamma emitting natural radionuclides in some Egyptian building materials.

    Science.gov (United States)

    Moharram, B M; Suliman, M N; Zahran, N F; Shennawy, S E; El Sayed, A R

    2012-01-01

    Using of building materials containing naturally occurring radionuclides as (238)U, (232)Th and (40)K and their progeny results in an external exposures of the housing of such buildings. In the present study, indoor dose rates for typical Egyptian rooms are calculated using the analytical method and activity concentrations of natural radionuclides in some building materials. Uniform chemical composition of the walls, floor and ceiling as well as uniform mass concentrations of the radionuclides in walls, floor and ceiling assumed. Different room models are assumed to discuss variation of indoor dose rates according to variation in room construction. Activity concentrations of (238)U, (232)Th and (40)K content in eight samples representative Clay soil and different building materials used in most recent Egyptian building were measured using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The specific activity for (238)U, (232)Th and (40)K, from the selected samples, were in the range 14.15-60.64, 2.75-84.66 and 7.35-554.4Bqkg(-1), respectively. The average indoor absorbed dose rates in air ranged from 0.005μGyh(-1) to 0.071μGyh(-1) and the corresponding population-weighted annual effective dose due to external gamma radiation varies from 0.025 to 0.345mSv. An outdoor dose rate for typical building samples in addition to some radiological hazards has been introduced for comparison. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Mortality from solid cancers other than lung, liver, and bone in relation to external dose among plutonium and non-plutonium workers in the Mayak Worker Cohort

    Energy Technology Data Exchange (ETDEWEB)

    Sokolnikov, Mikhail [Southern Urals Biophysics Institute, Ozyorsk (Russian Federation); Preston, Dale [Hirosoft International Corporation, Eureka, CA (United States); Stram, Daniel O. [University of Southern California, Keck School of Medicine, Los Angeles, CA (United States)

    2017-03-15

    Exposure to ionizing radiation has well-documented long-term effects on cancer rates and other health outcomes in humans. While in vitro experimental studies had demonstrated that the nature of some radiation effects depend on both total dose of the radiation and the dose rate (i.e., the pattern of dose distribution over time), the question of whether or not the carcinogenic effect of radiation exposure depends on the dose rate remains unanswered. Another issue of interest concerns whether or not concomitant exposure to external gamma rays and inhaled plutonium aerosols has any effect on the external exposure effects. The analyses of the present paper focus on the risk of solid cancers at sites other than lung, liver, and bone in Mayak workers. Recent findings are reviewed indicating that there is no evidence of plutonium dose response for these cancers in the Mayak worker cohort. Then the evidence for differences in the external dose effects among workers with and without the potential for exposure to alpha particles from inhaled plutonium is examined. It is found that there is no evidence that exposure to plutonium aerosols significantly affects the risk associated with external exposure. While the Mayak external dose risk estimate of an excess relative risk of 0.16 per Gy is somewhat lower than an appropriately normalized risk estimate from the Life Span Study of Japanese atomic bomb survivors, the uncertainties in these estimates preclude concluding that the external dose excess relative risks of this group of solid cancers differ in the two cohorts. (orig.)

  10. Mortality from solid cancers other than lung, liver, and bone in relation to external dose among plutonium and non-plutonium workers in the Mayak Worker Cohort

    International Nuclear Information System (INIS)

    Sokolnikov, Mikhail; Preston, Dale; Stram, Daniel O.

    2017-01-01

    Exposure to ionizing radiation has well-documented long-term effects on cancer rates and other health outcomes in humans. While in vitro experimental studies had demonstrated that the nature of some radiation effects depend on both total dose of the radiation and the dose rate (i.e., the pattern of dose distribution over time), the question of whether or not the carcinogenic effect of radiation exposure depends on the dose rate remains unanswered. Another issue of interest concerns whether or not concomitant exposure to external gamma rays and inhaled plutonium aerosols has any effect on the external exposure effects. The analyses of the present paper focus on the risk of solid cancers at sites other than lung, liver, and bone in Mayak workers. Recent findings are reviewed indicating that there is no evidence of plutonium dose response for these cancers in the Mayak worker cohort. Then the evidence for differences in the external dose effects among workers with and without the potential for exposure to alpha particles from inhaled plutonium is examined. It is found that there is no evidence that exposure to plutonium aerosols significantly affects the risk associated with external exposure. While the Mayak external dose risk estimate of an excess relative risk of 0.16 per Gy is somewhat lower than an appropriately normalized risk estimate from the Life Span Study of Japanese atomic bomb survivors, the uncertainties in these estimates preclude concluding that the external dose excess relative risks of this group of solid cancers differ in the two cohorts. (orig.)

  11. Characterization of the dose perturbation in tissue by stents as a function of external beam energy

    International Nuclear Information System (INIS)

    Schell, M.C.; Rosenzweig, D.P.; Weaver, K.A.; Rubin, P.

    1997-01-01

    Purpose: External beam irradiation of coronary arteries was shown to be detrimental in an animal model for the prevention of neointimal hyperplasia in the presence of stents when orthovoltage x-ray beams are used. This present study investigated the effect of beam energy on the dose distribution in the wall of the artery as a function of energy in the presence of stents in order to ascertain the effect on the dose due to beam energy. Materials and Methods: 250 kVp x-rays and 6-MV x rays were used to irradiate a stent placed in an homogeneous phantom. Radiochromic film densitometry and Monte Carlo calculations were used to measure and to simulate the dose distribution in the proximity of the stent. Result: External beam irradiation was reported to not only fail to prevent neointimal hyperplasia, but actually accentuate the neointimal response to a prompt mechanical injury in the artery. The photoelectric effect, which dominates low-energy x-ray interactions, produces recoil electrons in the stent which enhance the dose surrounding intima. The photoelectrons generated in nickel and iron have an extremely short range in normal tissue, approximately 0.1 mm. Initial estimates of orthovoltage x-ray interactions with the stent indicate a dose enhancement in the orthovoltage range by a factor of 2 to 3 due to the rise in the photoelectric cross section in this energy range depending on the elemental composition of the stent. Film densitometry verifies this dose enhancement. The Monte Carlo calculations yield a dose enhancement and the dose fall off with distance from the stent when irradiated with orthovoltage x-rays. Conversely when the tissue and stent are irradiated with megavoltage x-rays, the dose enhancement in this region is a factor of 1.15 in close proximity to the stent and 1.0 at distances greater than 0.1 mm. 6-MV photon interactions in tissue and iron are predominantly through Compton scattering. The Compton effect is dependent on the electron density in the

  12. Calculation of dose-rate conversion factors for external exposure to photons and electrons

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1978-01-01

    Methods are presented for the calculation of dose-rate conversion factors for external exposure to photon and electron radiation from radioactive decay. A dose-rate conversion factor is defined as the dose-equivalent rate per unit radionuclide concentration. Exposure modes considered are immersion in contaminated air, immersion in contaminated water, and irradiation from a contaminated ground surface. For each radiation type and exposure mode, dose-rate conversion factors are derived for tissue-equivalent material at the body surface of an exposed individual. In addition, photon dose-rate conversion factors are estimated for 22 body organs. The calculations are based on the assumption that the exposure medium is infinite in extent and that the radionuclide concentration is uniform. The dose-rate conversion factors for immersion in contaminated air and water then follow from the requirement that all of the energy emitted in the radioactive decay is absorbed in the infinite medium. Dose-rate conversion factors for ground-surface exposure are calculated at a reference location above a smooth, infinite plane using the point-kernel integration method and known specific absorbed fractions for photons and electrons in air

  13. Estimation of annual dose equivalent (internal and external) for new thorium plant workers of IRE OSCOM, Orissa

    International Nuclear Information System (INIS)

    Vidya Sagar, D.; Tripathy, S.K.; Khan, A.H.; Maharana, L.N.

    2001-01-01

    In addition to thoron, thoron daughters and gamma radiation, the New Thorium Plant workers are exposed to long lived alpha emitters due to inhalation of thorium fine dust present in the working environment. Air samplers were used for measurement of thoron daughters and long lived alpha concentration. Each sample was counted for 3-4 hours for alpha activity and the long lived alpha concentration was calculated after taking the self absorption effect of the deposit on the filter paper into account. Internal dose of individual workers due to thoron daughter concentration and long lived alpha concentration was determined using time weighted factors. Based on the results, it is observed that contribution of thoron daughters, long lived alpha and external gamma is about 2 mSv /y, 1 mSv /y and 5 mSv/y, respectively, to total dose to the workers. (author)

  14. Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers

    International Nuclear Information System (INIS)

    Park, Jun Chul; Pyo, Sung Jae

    2012-01-01

    The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like 99m Tc-HDP and 18 F-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety

  15. Modelling normal tissue isoeffect distribution in conformal radiotherapy of glioblastoma provides an alternative dose escalation pattern through hypofractionation without reducing the total dose

    International Nuclear Information System (INIS)

    Mangel, L.; Skriba, Z.; Major, T.; Polgar, C.; Fodor, J.; Somogyi, A.; Nemeth, G.

    2002-01-01

    The purpose of this study was to prove that by using conformal external beam radiotherapy (RT) normal brain structures can be protected even when applying an alternative approach of biological dose escalation: hypofractionation (HOF) without total dose reduction (TDR). Traditional 2-dimensional (2D) and conformal 3-dimensional (3D) treatment plans were prepared for 10 gliomas representing the subanatomical sites of the supratentorial brain. Isoeffect distributions were generated by the biologically effective dose (BED) formula to analyse the effect of conventionally fractionated (CF) and HOF schedules on both the spatial biological dose distribution and biological dose-volume histograms. A comparison was made between 2D-CF (2.0 Gy/day) and 3D-HOF (2.5 Gy/day) regimens, applying the same 60 Gy total doses. Integral biologically effective dose (IBED) and volumes received biologically equivalent to a dose of 54 Gy or more (V-BED54) were calculated for the lower and upper brain stem as organs of risk. The IBED values were lower with the 3D-HOF than with the 2D-CF schedule in each tumour location, means 22.7±17.1 and 40.4±16.9 in Gy, respectively (p<0.0001). The V-BED54 values were also smaller or equal in 90% of the cases favouring the 3D-HOF scheme. The means were 2.7±4.8 ccm for 3D-HOF and 10.7±12.7 ccm for 2D-CF (p=0.0006). Our results suggest that with conformal RT, fraction size can gradually be increased. HOF radiotherapy regimens without TDR shorten the treatment time and seem to be an alternative way of dose escalation in the treatment of glioblastoma

  16. Modelling normal tissue isoeffect distribution in conformal radiotherapy of glioblastoma provides an alternative dose escalation pattern through hypofractionation without reducing the total dose

    Energy Technology Data Exchange (ETDEWEB)

    Mangel, L.; Skriba, Z.; Major, T.; Polgar, C.; Fodor, J.; Somogyi, A.; Nemeth, G. [National Research Inst. for Radiobiology and Radiohygiene, Budapest (Hungary)

    2002-04-01

    The purpose of this study was to prove that by using conformal external beam radiotherapy (RT) normal brain structures can be protected even when applying an alternative approach of biological dose escalation: hypofractionation (HOF) without total dose reduction (TDR). Traditional 2-dimensional (2D) and conformal 3-dimensional (3D) treatment plans were prepared for 10 gliomas representing the subanatomical sites of the supratentorial brain. Isoeffect distributions were generated by the biologically effective dose (BED) formula to analyse the effect of conventionally fractionated (CF) and HOF schedules on both the spatial biological dose distribution and biological dose-volume histograms. A comparison was made between 2D-CF (2.0 Gy/day) and 3D-HOF (2.5 Gy/day) regimens, applying the same 60 Gy total doses. Integral biologically effective dose (IBED) and volumes received biologically equivalent to a dose of 54 Gy or more (V-BED54) were calculated for the lower and upper brain stem as organs of risk. The IBED values were lower with the 3D-HOF than with the 2D-CF schedule in each tumour location, means 22.7{+-}17.1 and 40.4{+-}16.9 in Gy, respectively (p<0.0001). The V-BED54 values were also smaller or equal in 90% of the cases favouring the 3D-HOF scheme. The means were 2.7{+-}4.8 ccm for 3D-HOF and 10.7{+-}12.7 ccm for 2D-CF (p=0.0006). Our results suggest that with conformal RT, fraction size can gradually be increased. HOF radiotherapy regimens without TDR shorten the treatment time and seem to be an alternative way of dose escalation in the treatment of glioblastoma.

  17. Marrow toxicity of fractionated vs. single dose total body irradiation is identical in a canine model

    International Nuclear Information System (INIS)

    Storb, R.; Raff, R.F.; Graham, T.; Appelbaum, F.R.; Deeg, H.J.; Schuening, F.G.; Shulman, H.; Pepe, M.

    1993-01-01

    The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing 60 Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionated total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs

  18. Doses from external irradiation to Marshall Islanders from Bikini and Enewetak nuclear weapons tests.

    Science.gov (United States)

    Bouville, André; Beck, Harold L; Simon, Steven L

    2010-08-01

    Annual doses from external irradiation resulting from exposure to fallout from the 65 atmospheric nuclear weapons tests conducted in the Marshall Islands at Bikini and Enewetak between 1946 and 1958 have been estimated for the first time for Marshallese living on all inhabited atolls. All tests that deposited fallout on any of the 23 inhabited atolls or separate reef islands have been considered. The methodology used to estimate the radiation doses at the inhabited atolls is based on test- and location-specific radiation survey data, deposition density estimates of 137Cs, and fallout times-of-arrival provided in a companion paper (Beck et al.), combined with information on the radionuclide composition of the fallout at various times after each test. These estimates of doses from external irradiation have been combined with corresponding estimates of doses from internal irradiation, given in a companion paper (Simon et al.), to assess the cancer risks among the Marshallese population (Land et al.) resulting from exposure to radiation from the nuclear weapons tests.

  19. Verification by the FISH translocation assay of historic doses to Mayak workers from external gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sotnik, Natalia V.; Azizova, Tamara V. [Southern Urals Biophysics Institute (SUBI), Ozyorsk, Chelyabinsk Region (Russian Federation); Darroudi, Firouz [Leiden University Medical Center, Department of Toxicogenetics, Leiden (Netherlands); College of North Atlantic, Department of Health Science, Centre for Human Safety and Environmental Research, Doha (Qatar); Ainsbury, Elizabeth A.; Moquet, Jayne E.; Lloyd, David C.; Hone, Pat A.; Edwards, Alan A. [Public Health England, Chilton, Oxfordshire (United Kingdom); Fomina, Janna [Leiden University Medical Center, Department of Toxicogenetics, Leiden (Netherlands)

    2015-11-15

    The aim of this study was to apply the fluorescence in situ hybridization (FISH) translocation assay in combination with chromosome painting of peripheral blood lymphocytes for retrospective biological dosimetry of Mayak nuclear power plant workers exposed chronically to external gamma radiation. These data were compared with physical dose estimates based on monitoring with badge dosimeters throughout each person's working life. Chromosome translocation yields for 94 workers of the Mayak production association were measured in three laboratories: Southern Urals Biophysics Institute, Leiden University Medical Center and the former Health Protection Agency of the UK (hereinafter Public Health England). The results of the study demonstrated that the FISH-based translocation assay in workers with prolonged (chronic) occupational gamma-ray exposure was a reliable biological dosimeter even many years after radiation exposure. Cytogenetic estimates of red bone marrow doses from external gamma rays were reasonably consistent with dose measurements based on film badge readings successfully validated in dosimetry system ''Doses-2005'' by FISH, within the bounds of the associated uncertainties. (orig.)

  20. Dielectric parameters of blood plasma in rats at external and internal irradiation with sublethal doses

    International Nuclear Information System (INIS)

    Khadzhidekova, E.; Kiradzhiev, G.

    1991-01-01

    Sexually mature male rats have received external gamma irradiation with 50, 200 or 380 cGy, treated with 89 Sr (333 or 1665 kBq per rat, femur dose 70, resp. 290 cGy), or 144 Ce (370 kBq per rat, liver dose 70 cGy). Dielectric parameters (permittivity and conductivity) have been measured in the frequency range 1.4 - 17 Mhz on different terms (1 to 30th day after the treatment). For all groups and terms the coefficients and equations describing the relationship between the dielectric permittivity ε and the frequency ν of the changing electric field have been calculated. On the basis of dielectric parameters the relaxation time of the plasma protein molecules is determined. It has been shown that the changes in dielectric permittivity are expressed at different frequencies specific for a given dose; the same is established for the conditions of internal irradiation. The frequency dependence of the permittivity is described as an exponential curve analogous to that of the control but with a changed exponent. In applying higher doses or activities the relationship turns from exponential to parabolic. The relaxation time, expressing the changes in conformal state of macromolecules, varies but is in all cases longer than one of the controls for the whole period of study at external irradiation with 50 and 380 cGy. It is lower at irradiation with 200 cGy, as well as at internal irradiation. 3 tabs., 13 refs

  1. Compendium of Total Ionizing Dose and Displacement Damage for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    Cochran, Donna J.; Boutte, Alvin J.; Chen, Dakai; Pellish, Jonathan A.; Ladbury, Raymond L.; Casey, Megan C.; Campola, Michael J.; Wilcox, Edward P.; Obryan, Martha V.; LaBel, Kenneth A.; hide

    2012-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear, and hybrid devices.

  2. Improved estimates of external gamma dose rates in the environs of Hinkley Point Power Station

    International Nuclear Information System (INIS)

    Macdonald, H.F.; Thompson, I.M.G.

    1988-07-01

    The dominant source of external gamma dose rates at centres of population within a few kilometres of Hinkley Point Power Station is the routine discharge of 41-Ar from the 'A' station magnox reactors. Earlier estimates of the 41-Ar radiation dose rates were based upon measured discharge rates, combined with calculations using standard plume dispersion and cloud-gamma integration models. This report presents improved dose estimates derived from environmental gamma dose rate measurements made at distances up to about 1 km from the site, thus minimising the degree of extrapolation introduced in estimating dose rates at locations up to a few kilometres from the site. In addition, results from associated chemical tracer measurements and wind tunnel simulations covering distances up to about 4 km from the station are outlined. These provide information on the spatial distribution of the 41-Ar plume during the initial stages of its dispersion, including effects due to plume buoyancy and momentum and behaviour under light wind conditions. In addition to supporting the methodology used for the 41-Ar dose calculations, this information is also of generic interest in the treatment of a range of operational and accidental releases from nuclear power station sites and will assist in the development and validation of existing environmental models. (author)

  3. In-vivo (entrance) dose measurements in external beam radiotherapy with aqueous FBX dosimetry system

    International Nuclear Information System (INIS)

    Semwal, M.K.; Thakur, P.K.; Bansal, A.K.; Vidyasagar, P.B.

    2005-01-01

    FBX aqueous chemical dosimetry system has been found useful in radiotherapy owing to its low dose measuring capability. In the present work, entrance dose measurements in external beam radiotherapy on a telecobalt machine were carried out with the system on 100 patients. Treatments involving simple beam arrangement of open parallel-opposed beams in cranial and pelvic irradiations were selected for this study. In place of a spectrophotometer, a simple and inexpensive colorimeter was used for absorbance measurements. The purpose was to assess the efficacy of the FBX system for in-vivo dose measurements. The results obtained show that the average discrepancy between the measured and expected dose for both categories of patients was 0.2% (standard deviation 3.2%) with a maximum of +1 0.3%. There were 5.5% cases showing more than ± 5% discrepancy. Comparison of the results obtained with published work on entrance dose measurements, with diode detectors, shows that the inexpensive FBX system can be used for in-vivo (entrance) dose measurements for simple beam arrangements in radiotherapy and can thus serve as a useful QA tool. (author)

  4. Organ-specific external dose coefficients and protective apron transmission factors for historical dose reconstruction for medical personnel.

    Science.gov (United States)

    Simon, Steven L

    2011-07-01

    While radiation absorbed dose (Gy) to the skin or other organs is sometimes estimated for patients from diagnostic radiologic examinations or therapeutic procedures, rarely is occupationally-received radiation absorbed dose to individual organs/tissues estimated for medical personnel; e.g., radiologic technologists or radiologists. Generally, for medical personnel, equivalent or effective radiation doses are estimated for compliance purposes. In the very few cases when organ doses to medical personnel are reconstructed, the data is usually for the purpose of epidemiologic studies; e.g., a study of historical doses and risks to a cohort of about 110,000 radiologic technologists presently underway at the U.S. National Cancer Institute. While ICRP and ICRU have published organ-specific external dose conversion coefficients (DCCs) (i.e., absorbed dose to organs and tissues per unit air kerma and dose equivalent per unit air kerma), those factors have been published primarily for mono-energetic photons at selected energies. This presents two related problems for historical dose reconstruction, both of which are addressed here. It is necessary to derive conversion factor values for (1) continuous distributions of energy typical of diagnostic medical x-rays (bremsstrahlung radiation), and (2) energies of particular radioisotopes used in medical procedures, neither of which are presented in published tables. For derivation of DCCs for bremsstrahlung radiation, combinations of x-ray tube potentials and filtrations were derived for different time periods based on a review of relevant literature. Three peak tube potentials (70 kV, 80 kV, and 90 kV) with four different amounts of beam filtration were determined to be applicable for historic dose reconstruction. The probabilities of these machine settings were assigned to each of the four time periods (earlier than 1949, 1949-1954, 1955-1968, and after 1968). Continuous functions were fit to each set of discrete values of the

  5. Adjuvant high-dose-rate brachytherapy after external beam radiotherapy in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Oezyar, Enis; Yildz, Ferah; Akyol, Fadil H.; Atahan, I. Lale

    2002-01-01

    Purpose: To compare the local control and survival rates obtained with either external beam radiation therapy (ERT) and adjuvant high-dose-rate (HDR) brachytherapy (BRT) or ERT alone in patients with nasopharyngeal cancer. Methods and Materials: Between December 1993 and December 1999, 144 patients (106 male, 38 female) with the diagnosis of nasopharyngeal cancer were treated with either ERT and adjuvant HDR BRT (Group A) or ERT alone (Group B) at our department. BRT was not applied in 38 patients for the following reasons: (1) Unit was unavailable (n=13), (2) Patient was younger than 18 years (n=17), (3) Patient received accelerated hyperfractionated ERT (n=6), and (4) Patient refused BRT (n=2). The median age for whole group was 43 (range: 9-82 years). According to the AJCC-1997 staging system, there were 11 (7.6%), 35 (24.3%), 38 (26.4%), and 60 (41.7%) patients in Stage I, II, III, and IV, respectively. There were 57 (39.6%) patients with T1, 41 (28.5%) with T2, 20 (13.9%) with T3, and 26 (18.1%) with T4 tumors. Histopathologic diagnosis was WHO 2-3 in 137 (95.2%) patients. ERT doses ranged between 58.8 and 74 Gy (median: 66 Gy). There were significantly more patients with young age, N2 status, and Stage III disease in Group B and with Stage II disease in Group A. Significantly more patients received chemotherapy in Group B. BRT with an HDR 192 Ir microSelectron afterloading unit was delivered in 106 patients at the conclusion of ERT using a single-channel nasal applicator. Dose was prescribed at 1 cm from the source, and total dose of 12 Gy in 3 fractions on 3 consecutive days was given immediately after ERT. Besides radiotherapy, 82 (56.9%) patients received cisplatin-based chemotherapy, as well. Follow-up time ranged between 12 and 80 months (median: 32 months). Results: The two groups were comparable in terms of local recurrence, locoregional failure, regional failure, and rate of distant metastasis. Local failure was observed in 11 (10.3%) out of 106

  6. Individual monitoring of external exposure in terms of personal dose equivalent, Hp(d)

    International Nuclear Information System (INIS)

    Fantuzzi, E.

    2001-01-01

    The institute for Radiation Protection of ENEA - Bologna has organised a one day-workshop on the subject: Individual monitoring of external exposure in terms of personal dose equivalent, H p (d). The aim of the workshop was the discussion of the new implications and modifications to be expected in the routine individual monitoring of external radiation, due to the issue of the Decree 241/00 (G.U. 31/8/2000) in charge since 01/01/2001. The decree set up in Italian law the standards contained in the European Directive EURATOM 96/29-Basic Standards for the Protection of Health of Workers and the General Public against Dangers arising from Ionizing Radiation. Among others, the definition of the operational quantities for external radiation for personal and environmental monitoring, H p (d) e H * (d) respectively as defined by ICRU (International Commission for Radiation Units and Measurements), requires to update the methods of measurements and calibration of the personal dosemeters and environmental monitors. This report collects the papers presented at the workshop dealing with the Personal Dose Equivalent, H p (d), the conversion coefficients, H p (d)/K a e H p (d)/ , obtained through Monte Carlo calculations published by ICRU and ICRP (International Commission for Radiation Protection), the new calibration procedures and the practical implication in the routine of individual monitoring in terms of H p (d). Eventually, in the last chapter, the answers to Frequently Asked Questions (FAQ) are briefly reported [it

  7. External beam radiotherapy for painful osseous metastases: pooled data dose response analysis

    International Nuclear Information System (INIS)

    Ben-Josef, Edgar; Shamsa, Falah; Youssef, Emad; Porter, Arthur T.

    1999-01-01

    Purpose: Although the effectiveness of external beam irradiation in palliation of pain from osseous metastases is well established, the optimal fractionation schedule has not been determined. Clinical studies to date have failed to demonstrate an advantage for higher doses. To further address this issue, we conducted a pooled dose response analysis using data from published Phase III clinical trials. Methods and Materials: Complete response (CR) was used as an endpoint because it was felt to be least susceptible to inconsistencies in assessment.The biological effective dose (BED) was calculated for each schedule using the linear-quadratic model and an α/β of 10. Using SAS version 6.12, the data were fitted using a weighted linear regression, a logistic model, and the spline technique. Finally, BED was categorized, and odds ratios for each level were calculated. Results: CR was assessed early and late in 383 and 1,007 patients, respectively. Linear regression on the early-response data yielded a poor fit and a nonsignificant dose coefficient. With the late-response data, there was an excellent fit (R-square = 0.842) and a highly significant dose coefficient (p = 0.0002). Fitting early CR to a logistic model, we could not establish a significant dose response relationship. However, with the late-response data there was an excellent fit and the dose coefficient was significantly different from zero (0.017 ± 0.00524; p = 0.0012). Application of the spline technique or removal of an outlier resulted in an improved fit (p 0.048 and p = 0.0001, respectively). Using BED of < 14.4 Gy as a reference level, the odds ratios for late CR were 2.29-3.32 (BED of 19.5-51.4 Gy, respectively). Conclusion: Our results demonstrate a clear dose-response for pain relief. Further testing of high intensity regiments is warranted

  8. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    International Nuclear Information System (INIS)

    Flickinger, J.C.; Kalend, A.

    1990-01-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab

  9. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Flickinger, J C; Kalend, A [Pittsburgh University School of Medicine (USA). Department of Radiation Oncology Pittsburg Cancer Institute (USA)

    1990-03-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab.

  10. A method to combine three dimensional dose distributions for external beam and brachytherapy radiation treatments for gynecological neoplasms

    International Nuclear Information System (INIS)

    Narayana, V.; Sahijdak, W.M.; Orton, C.G.

    1997-01-01

    Purpose: Radiation treatment of gynecological neoplasms, such as cervical carcinoma, usually combines external radiation therapy with one or more intracavitary brachytherapy applications. Although the dose from external beam radiation therapy and brachytherapy can be calculated and displayed in 3D individually, the dose distributions are not combined. At most, combined point doses are calculated for select points using various time-dose models. In this study, we present a methodology to combine external beam and brachytherapy treatments for gynecological neoplasms. Material and Methods: Three dimensional bio-effect treatment planning to obtain complication probability has been outlined. CT scans of the patient's pelvis with the gynecological applicator in place are used to outline normal tissue and tumor volumes. 3D external beam and brachytherapy treatment plans are developed separately and an external beam dose matrix and a brachytherapy dose matrix was calculated. The dose in each voxel was assumed to be homogeneous. The physical dose in each voxel of the dose matrix was then converted into extrapolated response dose (ERD) based on the linear quadratic model that accounts for the dose per fraction, number of fractions, dose rate, and complete or incomplete repair of sublethal damage (time between fractions). The net biological dose delivered was obtained by summing the ERD grids from external beam and brachytherapy since there was complete repair of sublethal damage between external beam and brachytherapy treatments. The normal tissue complication probability and tumor control probability were obtained using the biological dose matrix based on the critical element model. Results: The outlined method of combining external beam and brachytherapy treatments was implemented on gynecological treatments using an applicator for brachytherapy treatments. Conclusion: Implementation of the biological dose calculation that combine different modalities is extremely useful

  11. Reasons between effective doses for tomographic and mathematical models due to external exposition by photons

    International Nuclear Information System (INIS)

    Kramer, R.; Khoury, H.J.; Yoriyaz, H.; Lima, F.R.A.; Loureiro, E.C.M.

    2005-01-01

    The development of Monte Carlo codes and new and sophisticated tomographic human models, or based on voxel, motivated the ICRP to propose a revision of the traditional exposition models, which have been used to calculate doses on organs and tissues using mathematical phantoms MIRD-type 5. This article presents calculations made with tomographic phantoms MAX (Male Adult voXel) and FAX (Female Adult voXel), recently developed and also, for comparison, with ADAM and Eve mathematician phantoms. All models were coupled to the EGS4 and MCNP4 codes for full body external irradiation by photons. It were simulated expositions AP, PA and rotational for energies varying between 10 keV and 10 MeV. The effective calculated doses were compared separately to evaluate: the replacement of the Monte Carlo code; the composition of the tissues and the replacement of tomographic phantoms by mathematical ones. Effective doses calculated results indicate that for external exposures by photons to introduce models based on voxels can cause a reduction of about 10% to the energies considered in this study

  12. Randomized controlled trial on postoperative pulmonary humidification after total laryngectomy: External humidifier versus heat and moisture exchanger

    NARCIS (Netherlands)

    Mérol, Jean-Claude; Charpiot, Anne; Langagne, Thibault; Hémar, Patrick; Ackerstaff, Annemieke H.; Hilgers, Frans J. M.

    2012-01-01

    Objectives/Hypothesis: Assessment of immediate postoperative airway humidification after total laryngectomy (TLE), comparing the use of an external humidifier (EH) with humidification through a heat and moisture exchanger (HME). Study Design: Randomized controlled trial (RCT). Methods: Fifty-three

  13. Randomized controlled trial on postoperative pulmonary humidification after total laryngectomy: external humidifier versus heat and moisture exchanger

    NARCIS (Netherlands)

    Mérol, J.-C.; Charpiot, A.; Langagne, T.; Hémar, P.; Ackerstaff, A.H.; Hilgers, F.J.M.

    2012-01-01

    Objectives/Hypothesis: Assessment of immediate postoperative airway humidification after total laryngectomy (TLE), comparing the use of an external humidifier (EH) with humidification through a heat and moisture exchanger (HME). Study Design: Randomized controlled trial (RCT). Methods: Fifty-three

  14. Estimate on external effective doses received by the Iranian population from environmental gamma radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Roozitalab, J.; Reza deevband, M.; Rastkhah, N. [National Radiation Protection Dept. Atomic Energy Organization (Iran, Islamic Republic of); Sohrabi, M. [Intenatinal atomic Energy Agency, Vienna (Austria)

    2006-07-01

    Concentration of natural radioactive materials, especially available U 238, Ra 226, Th 232, and K 40 in construction materials and soil, as well as absorb dose from cosmic rays, is the most important source of the people for effective doses from the environment radiation. In order to evaluate external effective dose, it has been carried out more than 1000 measurements in 36 cities by sensitive dosimeters to environmental gamma radiation for indoor and outdoor conditions in residential areas; which its results show that range of gamma exposure for inside of buildings in Iran is 8.7-20.5 {mu}R/h, and outdoor environments of different cities is 7.9-20.6 {mu}R/h, which their mean value are 14.33 and 12.62 {mu}R/h respectively. Meanwhile, it has been estimated that beam-absorbing ratio between indoor and outdoor in measured environments is 1.55, except contribution of cosmic rays. This studies show that average effective dose for each Iranian person from environmental gamma is 96.9 n Sv/h, and annually effective dose for every person is 0.848 mSv. (authors)

  15. Estimation of delivered doses to the fetus in a external radiation therapy treatment of megavoltage

    International Nuclear Information System (INIS)

    Ruggeri, Ricardo M.; Mairal, Liliana; Scarabino, Mara L.; Colombo, Soledad; Sardi, Mabel

    2013-01-01

    This work, stimulated by the entrance to our radiotherapy service several cases of central nervous system injury in pregnant patients, involves the estimation of doses to the fetus from the comparative analysis and verification of theoretical and experimental data. Um phantom was designed with the pregnant morphology about 28 weeks gestation, with inserts for waterproof ionization chamber in the head and abdominal area. From the scan of the anthropomorphic phantom were reproduced in 3D planner treatments comprised of pregnant patients, estimating the dose in the lesion and at different points in the abdominal area. With the phantom in the beam of radiation treatment conditions were measured with the camera dose at the same points of the abdomen mentioned and the isocenter of the injury. The dose was also measured on surface of the abdominal area with diode array to establish correlation with the measured dose ionization chamber calibrated with water. The work provided medical radiotherapists fundamental experimental data for elevated risk assessment framework for radiation protection of the fetus. It also set the reference calibration for in vivo dosimetry in the abdominal area in pregnant patients treated for external radiotherapy. The results obtained with the implemented dosimetry design will determine the procedures that will form the operating rules institution and thus how professionals working within it

  16. Estimate on external effective doses received by the Iranian population from environmental gamma radiation sources

    International Nuclear Information System (INIS)

    Roozitalab, J.; Reza deevband, M.; Rastkhah, N.; Sohrabi, M.

    2006-01-01

    Concentration of natural radioactive materials, especially available U 238, Ra 226, Th 232, and K 40 in construction materials and soil, as well as absorb dose from cosmic rays, is the most important source of the people for effective doses from the environment radiation. In order to evaluate external effective dose, it has been carried out more than 1000 measurements in 36 cities by sensitive dosimeters to environmental gamma radiation for indoor and outdoor conditions in residential areas; which its results show that range of gamma exposure for inside of buildings in Iran is 8.7-20.5 μR/h, and outdoor environments of different cities is 7.9-20.6 μR/h, which their mean value are 14.33 and 12.62 μR/h respectively. Meanwhile, it has been estimated that beam-absorbing ratio between indoor and outdoor in measured environments is 1.55, except contribution of cosmic rays. This studies show that average effective dose for each Iranian person from environmental gamma is 96.9 n Sv/h, and annually effective dose for every person is 0.848 mSv. (authors)

  17. High biologically effective dose radiation therapy using brachytherapy in combination with external beam radiotherapy for high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Keisei Okamoto

    2017-02-01

    Full Text Available Purpose : To evaluate the outcomes of high-risk prostate cancer patients treated with biologically effective dose (BED ≥ 220 Gy of high-dose radiotherapy, using low-dose-rate (LDR brachytherapy in combination with external beam radiotherapy (EBRT and short-term androgen deprivation therapy (ADT. Material and methods : From 2005 to 2013, a total of 143 patients with high-risk prostate cancer were treated by radiotherapy of BED ≥ 220 Gy with a combination of LDR brachytherapy, EBRT, and androgen deprivation therapy (ADT. The high-risk patients in the present study included both high-risk and very high-risk prostate cancer. The number of high-risk features were: 60 patients with 1 high-risk factor (42%, 61 patients with 2 high-risk factors (43%, and 22 patients with 3 high-risk factors (15% including five N1 disease. External beam radiotherapy fields included prostate and seminal vesicles only or whole pelvis depending on the extension of the disease. Biochemical failure was defined by the Phoenix definition. Results : Six patients developed biochemical failure, thus providing a 5-year actual biochemical failure-free survival (BFFS rate of 95.2%. Biochemical failure was observed exclusively in cases with distant metastasis in the present study. All six patients with biochemical relapse had clinical failure due to bone metastasis, thus yielding a 5-year freedom from clinical failure (FFCF rate of 93.0%. None of the cases with N1 disease experienced biochemical failure. We observed four deaths, including one death from prostate cancer, therefore yielding a cause-specific survival (CSS rate of 97.2%, and an overall survival (OS rate of 95.5%. Conclusions : High-dose (BED ≥ 220 Gy radiotherapy by LDR in combination with EBRT has shown an excellent outcome on BFFS in high-risk and very high-risk cancer, although causal relationship between BED and BFFS remain to be explained further.

  18. Evaluation of the absorbed doses in conditions of external and internal contamination with radionuclides

    International Nuclear Information System (INIS)

    Milivojevic, K.; Stojanovic, D.; Markovic, P.

    1981-01-01

    In experimental conditions of contamination with radionuclides of the skin and skin injuries, an evaluation of the degree of local irradiation in decontamined region and doses absorbed in organs of selective accumulating was carried out by use of mathematical models and tissue-equivalent thermoluminescent dosemeters. The evaluation of the absorbed doses based on conception, that in adequate analyses of decontamination effect, as a most efficient medico-prophilactic measure from local and total irradiation, should be taken into account the total body burden of the penetrated radionuclide, selective accumulating in critical organs or tissues, as well as the residual radioactivity in decontaminated region. (author)

  19. Internal and external dose conversion coefficient for domestic reference animals and plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Park, Du Won; Choi, Young Ho

    2009-07-15

    This report presents the internal and external dose conversion coefficients for domestic reference animals and plant, which are essential to assess the radiological impact of an environmental radiation on non-human species. To calculate the dose conversion coefficients, a uniform isotropic model and a Monte Carlo method for a photon transport simulation in environmental media with different densities have been applied for aquatic and terrestrial animals, respectively. In the modeling all the target animals are defined as a simple 3D elliptical shape. To specify the external radiation source it is assumed that aquatic animals are fully immersed in infinite and uniformly contaminated water, and the on-soil animals are living on the surface of a horizontally infinite soil source, and the in-soil organisms are living at the center of a horizontally infinite and uniformly contaminated soil to a depth of 50cm. A set of internal and external dose conversion coefficients for 8 Korean reference animals and plant (rat, roe-deer, frog, snake, Chinese minnow, bee, earthworm, and pine tree) are presented for 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, {sup 95}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, and {sup 240}Pu)

  20. Normal tissue tolerance to external beam radiation therapy: Thyroid; Dose de tolerance des tissus sains: la thyroide

    Energy Technology Data Exchange (ETDEWEB)

    Berges, O.; Giraud, P. [Service d' oncologie-radiotherapie, hopital europeen Georges-Pompidou, universite Paris Descartes, 75 - Paris (France); Belkacemi, Y. [Service d' oncologie-radiotherapie, CHU Henri-Mondor, universite Paris 12, 94 - Creteil (France)

    2010-07-15

    The thyroid is the most developed endocrine gland of the body. Due to its anatomical location, it may be exposed to ionizing radiation in external radiotherapy involving head and neck. This review aims to describe the thyroid radiation disorders, probably under-reported in the literature, their risk factors and follow-up procedures. The functional changes after external beam radiation consists mainly of late effects occurring beyond 6 months, and are represented by the clinical and subclinical hypothyroidism. Its incidence is approximately 20 to 30% and it can occur after more than 25 years after radiation exposure. Hyperthyroidism and auto-immune manifestations have been described in a lesser proportion. The morphological changes consist of benign lesions, primarily adenomas, and malignant lesions, the most feared and which incidence is 0.35%. The onset of hypothyroidism depends of the total dose delivered to the gland, and the irradiated. Modern techniques of conformal radiotherapy with modulated intensity could improve the preservation of the thyroid, at the expense of the increase in low doses and the theoretical risk of secondary cancers. (authors)

  1. Tomographic anthropomorphic models. Pt. 4. Organ doses for adults due to idealized external photon exposures

    CERN Document Server

    Zankl, M; Petoussi-Henss, N; Regulla, D

    2002-01-01

    The present report contains extensive tables and figures of conversion coefficients of organ and tissue equivalent dose, normalised to air kerma free in air for voxel anthropomorphic phantoms and for standard geometries of external photon radiation, estimated with Monte Carlo techniques. Four realistic adult voxel phantoms were used for the calculations, based on computed tomographic data of real people: three male phantoms, two of them being of average size, one representing a big man, and one female phantom of a tall and somewhat over weighted woman.

  2. Tomographic anthropomorphic models. Pt. 4. Organ doses for adults due to idealized external photon exposures

    International Nuclear Information System (INIS)

    Zankl, M.; Petoussi-Henss, N.; Fill, U.; Regulla, D.

    2002-01-01

    The present report contains extensive tables and figures of conversion coefficients of organ and tissue equivalent dose, normalised to air kerma free in air for voxel anthropomorphic phantoms and for standard geometries of external photon radiation, estimated with Monte Carlo techniques. Four realistic adult voxel phantoms were used for the calculations, based on computed tomographic data of real people: three male phantoms, two of them being of average size, one representing a big man, and one female phantom of a tall and somewhat over weighted woman. (orig.)

  3. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  4. SOILD: A computer model for calculating the effective dose equivalent from external exposure to distributed gamma sources in soil

    International Nuclear Information System (INIS)

    Chen, S.Y.; LePoire, D.; Yu, C.; Schafetz, S.; Mehta, P.

    1991-01-01

    The SOLID computer model was developed for calculating the effective dose equivalent from external exposure to distributed gamma sources in soil. It is designed to assess external doses under various exposure scenarios that may be encountered in environmental restoration programs. The models four major functional features address (1) dose versus source depth in soil, (2) shielding of clean cover soil, (3) area of contamination, and (4) nonuniform distribution of sources. The model is also capable of adjusting doses when there are variations in soil densities for both source and cover soils. The model is supported by a data base of approximately 500 radionuclides. 4 refs

  5. Cleanup techniques for Finnish urban environments and external doses from 137Cs - modelling and calculations

    International Nuclear Information System (INIS)

    Moring, M.; Markkula, M.L.

    1997-03-01

    The external doses under various radioactive deposition conditions are assessed and the efficiencies of some simple decontamination techniques (grass cutting, vacuum sweeping, hosing of paved surfaces and roofs, and felling trees) are compared in the study. The present model has been constructed for the Finnish conditions and housing areas, using 137 Cs transfer data from the Nordic and Central European studies and models. The compartment model concerns behaviour and decontamination of 137 Cs in the urban environment under summer conditions. Doses to man have been calculated for wet (light rain) and dry deposition in four typical Finnish building areas: single-family wooden houses, brick terraced-houses, blocks of flats and urban office buildings. (26 refs.)

  6. Long-term follow-up of low-dose external pituitary irradiation for Cushing's disease

    International Nuclear Information System (INIS)

    Littley, M.D.; Shalet, S.M.; Beardwell, C.G.; Ahmed, S.R.; Sutton, M.L.

    1990-01-01

    Twenty-four patients (three male) with Cushing's disease, aged between 11 and 67 years, were treated with low-dose external pituitary irradiation (20 Gy in eight fractions over 10-12 days) and followed for between 13 and 171 months (median 93 months). Eleven patients (46%) went into remission 4-36 months after irradiation, but five subsequently relapsed. In this series, the low incidence of radiation-induced hypopituitarism and absence of other complications attributable to radiotherapy suggest that low-dose pituitary irradiation may be a useful treatment option in selected patients. However, long-term follow-up has demonstrated a high relapse rate and failure to prevent Nelson's syndrome in adrenalectomized patients, indicating that it should not be used as primary treatment in preference to selective adenomectomy. (author)

  7. Time, dose and volume factors in interstitial brachytherapy combined with external irradiation for oral tongue carcinoma

    International Nuclear Information System (INIS)

    Yorozu, Atsunori

    1996-01-01

    This is a retrospective analysis of 136 patients with squamous cell carcinoma of stages I and II of the oral tongue who were treated with interstitial brachytherapy alone or in combination with external irradiation between 1976 and 1991. Control of the primary lesion and the occurrence of late complications were analyzed with respect to dose, time and tumor size with the Cox hazard model. The 5-year survival rates for stages I and II were 84.5% and 75.6%. The 5-year primary control rate was 91.3% for stage I and 77.3% for stage II (p 50 Gy compared with a brachytherapy dose 30 mm. Late complications should be reduced by using a spacer, improvements in dental and oral hygiene, and a sophisticated implant method. (author)

  8. Study on external dose around the Reactor TRIGA PUSPATI (RTP) Facility: A proposal

    International Nuclear Information System (INIS)

    Hairul Nizam Idris

    2012-01-01

    In order to meet the requirement of the recent regulation (AELB-BSRP 2010), it is absolutely necessary to re-execute the in-situ and accumulated external dose assessment at the surrounding area of the Reactor TRIGA PUSPATI (RTP) facility. A number of strategic locations will be identified for the points of the dose mapping. Selection of these measurement points will be base on certain factor such as physical shielding thickness, occupancy of the workers, and others. Then, several survey meters and dosimeter will be chosen base on measuring method, reactor radiation spectra energy, type of radiation and etc. The result obtained will be compared with action values or limits given by AELB- BSRP 2010 and also can be used as baseline data or report for future reference. (author)

  9. Volumes and doses for external radiotherapy - Definitions and recommendations; Volum og doser i ekstern straaleterapi - Definisjoner og anbefalinger

    Energy Technology Data Exchange (ETDEWEB)

    Levernes, Sverre (ed.)

    2012-07-01

    The report contains definitions of volume and dose parameters for external radiotherapy. In addition the report contains recommendations for use, documentation and minimum reporting for radiotherapy of the individual patient.(Author)

  10. Review of personal monitoring techniques for the measurement of absorbed dose from external beta and low energy photon radiation

    DEFF Research Database (Denmark)

    Christensen, Poul

    1986-01-01

    The techniques available at present for personal monitoring of doses from external beta and low energy photon radiation are reviewed. The performance of currently used dosimetry systems is compared with that recommended internationally, and developments for improving the actual performance...

  11. Natural radioactivity and external dose assessment of surface soils in Vietnam

    International Nuclear Information System (INIS)

    Huy, N. Q.; Hien, P. D.; Luyen, T. V.; Hoang, D. V.; Hiep, H. T.; Quang, N. H.; Long, N. Q.; Nhan, D. D.; Binh, N. T.; Hai, P. S.; Ngo, N. T.

    2012-01-01

    In this study, natural radioactivity in surface soils of Vietnam and external dose assessment to human population, deduced from activities of 226 Ra, 232 Th and 40 K nuclides, were determined. From 528 soil samples collected in 63 provinces of Vietnam, including five centrally governed cities, the average activities were obtained and equal to 42.77 ± 18.15 Bq kg -1 for 226 Ra, 59.84 ± 19.81 Bq kg -1 for 232 Th and 411.93 ± 230.69 Bq kg -1 for 40 K. The outdoor absorbed dose rates (OADRs) in air at 1 m above the ground level for 63 provinces were calculated, and their average value was 71.72 ± 24.72 nGy h -1 , with a range from 17.45 to 149.40 nGy h -1 . The population-weighted OADR of Vietnam was 66.70 nGy h -1 , which lies in the range of 18-93 nGy h -1 found in the World. From the OADRs obtained, it was estimated that the outdoor annual effective dose and indoor annual effective dose to the population were 0.082 and 0.458 mSv, which are higher than the corresponding values 0.07 and 0.41 mSv, respectively, of the World. The radium equivalent activity Ra eq and the external hazard index H ex of surface soils of Vietnam are lower than the corresponding permissible limits of 370 Bq kg -1 and 1, respectively. Therefore, soil from Vietnam is safe for the human population when it is used as a building material. (authors)

  12. Natural Radioactivity and External Dose Assessment of Surface Soils in Vietnam

    International Nuclear Information System (INIS)

    Huy, N.Q.; Hien, P.D.; Hoang, D.V.; Quang, N.H.; Long, N.Q.; Binh, N.T.; Hai, P.S.

    2012-01-01

    In this study, natural radioactivity in surface soils of Vietnam and external dose assessment to human population, deduces from activities of 226 Ra, 232 Th and 40 K nuclides, were determined. From 528 soil samples collected in 63 provinces of Vietnam, including five centrally governed cities, the average activities were obtained and equal to 42.77 ± 18.15 Bq kg -1 for 226 Ra, 59.84 ± 19.81 Bq kg -1 for 232 Th and 411.93 ± 230.69 Bq kg -1 for 40 K. The outdoor absorbed dose rates (OADRs) in air at 1 m above the ground level for 63 provinces were calculated, and their average value was 71.72 ± 24.72 nGy h -1 , with a range from 17.45 to 149.40 nGy h -1 . The population-weighted OADR of Vietnam was 66.70 nGy h -1 , which lies in the range of 18-93 nGy h -1 found in the World. From the OADR obtained, it was estimated that the outdoor annual effective dose and indoor annual effective dose to the population were 0.082 and 0.458 mSv, which are higher than the corresponding values 0.07 and 0.41 mSv, respectively, of the World. The radium equivalent activity Ra eq and the external hazard index H ex of surface soils of Vietnam are lower than the corresponding permissible limits of 370 Bq kg -1 and 1, respectively. Therefore, soil from Vietnam is safe for the human population when it used as a building material. (author)

  13. External dose rates from gamma rays and activity concentrations in foodstuffs and herbage in eastern Europe

    International Nuclear Information System (INIS)

    Wilkins, B.T.; Dodd, N.J.; Bradley, E.J.

    1986-01-01

    The initial scarcity of reliable information in eastern European countries, coupled with the proximity of the Chernobyl installation, resulted in understandable concern among British nationals living in these areas or visiting them on a short-term basis. Accordingly, arrangements were made by the Foreign and Commonwealth Office (FCO) for the appropriate Embassies to send samples of milk, drinking water, grass and available fruit and vegetables to the Board's laboratories at Chilton for analysis. In addition, simple monitoring equipment was supplied to the Embassies for measurements of external dose rates from gamma rays out of doors. The first set of samples was collected in Moscow on May 3rd 1986. Most consignments arrived at Chilton within 24 hours of collection. Speed was important, not only because of the need for information but because vegetation needed to be sufficiently fresh to permit meaningful measurement. By the end of June 1986, the results of systematic monitoring programmes in eastern Europe were being disseminated more freely, so that frequent sampling by the Embassies was no longer considered necessary. Since that time samples have been received only occasionally from those Embassies where concern still persists. This report summarises the results of measurements and samples taken by June 30th 1986. Data for γ-ray emitting radionuclides in foodstuffs were issued to the FCO in a series of Measurement Reports. Here they are presented together with data for actinide element concentrations in a limited number of samples. Measurements of outdoor external dose rates made by the Embassies are also included

  14. Probabilistic accident consequence uncertainty analysis -- Uncertainty assessment for deposited material and external doses. Volume 2: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Goossens, L.H.J.; Kraan, B.C.P.; Cooke, R.M. [Delft Univ. of Technology (Netherlands); Boardman, J. [AEA Technology (United Kingdom); Jones, J.A. [National Radiological Protection Board (United Kingdom); Harper, F.T.; Young, M.L. [Sandia National Labs., Albuquerque, NM (United States); Hora, S.C. [Univ. of Hawaii, Hilo, HI (United States)

    1997-12-01

    The development of two new probabilistic accident consequence codes, MACCS and COSYMA, was completed in 1990. These codes estimate the consequence from the accidental releases of radiological material from hypothesized accidents at nuclear installations. In 1991, the US Nuclear Regulatory Commission and the Commission of the European Communities began cosponsoring a joint uncertainty analysis of the two codes. The ultimate objective of this joint effort was to systematically develop credible and traceable uncertainty distributions for the respective code input variables. A formal expert judgment elicitation and evaluation process was identified as the best technology available for developing a library of uncertainty distributions for these consequence parameters. This report focuses on the results of the study to develop distribution for variables related to the MACCS and COSYMA deposited material and external dose models. This volume contains appendices that include (1) a summary of the MACCS and COSYMA consequence codes, (2) the elicitation questionnaires and case structures, (3) the rationales and results for the panel on deposited material and external doses, (4) short biographies of the experts, and (5) the aggregated results of their responses.

  15. External dose estimation of the human associated with companion animals under veterinary nuclear medical diagnosis

    International Nuclear Information System (INIS)

    Ito, Nobuhiko; Hanawa, Asumi; Suzuki, Kanan

    2004-01-01

    This study was performed in order to make a safety guideline for veterinary nuclear medicine in Japan. Well often used radionuclides ( 18 F and 99 mTc) were employed for evaluating the external radiation exposures of veterinarians, animal owners, and the public. The human external radiation exposure from radiation sources in phantom likened to animal was considered by comparing the results of computer simulation and the actually measured exposure. The computer simulation was performed by using macro program of Microsoft Visual Basic for Applications (VBA). In this simulation calculation process, radiation absorption and buildup were taken into consideration with the gamma ray emitted from radioactive materials in the body of the animal. Both corresponded well though the simulation result tended to be overvalued from the actual measurement value. Therefore, it is thought that this system can be applied to the estimation of human's external exposure. When the calculation was done on the condition that the radioactive substance exists only in internal organs (heart, liver, kidneys, and bladder), the unequal distribution of the dose rate was found near the animal body. External radiation exposure estimation to the veterinarian, the animal owner and the public was performed under consideration of the actual working condition, the distance from the source, and the time of exposure. In the calculation, the radiation dose of the animal owner and the public did not exceed the dose limit (5 mSv/yr for the animal owner, and 1 mSv/yr for the general public: International Commission of Radiological Protection (ICRP) 1990) in the release after 24 hours of the radiopharmaceutical administering. The calculation condition used in this study was actually more excessive. So the authors consider these exposures would cause no significant issue by starting the veterinary nuclear medicine in Japan. Moreover, since injected radiopharmaceutical is excreted out of the body actually, the

  16. High dose rate interstitial brachytherapy with external beam irradiation for localized prostate cancer. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Hiratsuka, Junichi; Jo, Yoshimasa; Yoden, Eisaku; Tanaka, Hiroyoshi; Imajo, Yoshinari [Kawasaki Medical School, Kurashiki, Okayama (Japan); Nagase, Naomi; Narihiro, Naomasa; Kubota, Juichi

    2000-12-01

    This study was undertaken to assess the biochemical and pathological results of combined external beam radiotherapy and high dose rate Ir-192 brachytherapy (HDR-Ir192) for clinically localized prostate cancer. Between October 1997 and August 1999, 39 evaluable patients with adenocarcinoma of prostate diagnosed by biopsy were treated with interstitial and external beam irradiation. Patients ranged in age from 58-82 years, with a mean of 69.7 years. T1c, T2 and T3 tumors, according to the UICC classification system (1997), were found in 7, 21 and 11 cases respectively. The mean initial pre-treatment PSA was 35.9 ng/ml (median 13.2), with 77% of the patients having had a pre-treatment PSA greater than 10 ng/ml. Of all patients, 17 had received pre-treatment hormonal therapy. Hormonal pretreatment was stopped at the beginning of radiotherapy in all cases. External beam four-field box irradiation was given to the small pelvis to a dose of 45 Gy/25 fractions. Three HDR-Ir192 treatments were given over a 30-h period, with 5.5 Gy per fraction at the circumference of the prostate gland over the course of this study. Biochemical failure was defined as a PSA level >1.5 ng/ml and rising on three consecutive values. If serial post-treatment PSA levels showed a continuous downward trend, failure was not scored. The patient with clinical evidence of progression was classified as a clinical failure. The median follow-up at the time of evaluation was 19.6 months. A post-treatment PSA level {<=}1.0 ng/ml was seen in 26 (67%) patients, and values from >1.0 to {<=}2.0 ng/ml were seen in 10 (26%) patients. Biochemical failure was not seen in 38 patients except for one patient who developed a distant bone metastasis with negative prostatic biopsy 15 months after treatment. Biochemical control rate was 100% (38/38) except for the patient with bone metastasis classified as clinical failure. Negative biopsies 18 months after treatment were found in 93% (14/15) of patients. Only one patient

  17. Impact of total ionizing dose on the electromagnetic susceptibility of a single bipolar transistor

    International Nuclear Information System (INIS)

    Doridant, A.; Jarrix, S.; Raoult, J.; Blain, A.; Dusseau, L.; Chatry, N.; Calvel, P.; Hoffmann, P.

    2012-01-01

    Space or military electronic components are subject to both electromagnetic fields and total ionizing dose. This paper deals with the electromagnetic susceptibility of a discrete low frequency transistor subject to total ionizing dose deposition. The electromagnetic susceptibility is investigated on both non-irradiated and irradiated transistors mounted in common emitter configuration. The change in susceptibility to 100 MHz-1.5 GHz interferences lights up a synergy effect between near field electromagnetic waves and total ionizing dose. Physical mechanisms leading to changes in signal output are detailed. (authors)

  18. Modulation of toxicity following external beam irradiation preceded by high-dose rate brachytherapy in inoperable oesophageal cancer

    International Nuclear Information System (INIS)

    Taal, B.G.; Aleman, B.M.P.; Koning, C.C.E.; Boot, H.

    1996-01-01

    To induce fast relief of dysphagia in inoperable oesephageal cancer, we applied high-dose rate (HDR) intraluminal irradiation followed by external irradiation (EBRT) in a phase II study. 15 patients (group A: n = 15; 10 men, 5 women; median age 66 years) were treated with 10 Gy HDR brachytherapy plus 40 Gy EBRT (15 fractions of 2.67 Gy). Severe side-effects were encountered in 60% of patients: 3 late ulceration, 2 pending fistula and 2 patients with fatal haemorrhage after an interval of 6 months. Overall response was excellent: 9 complete remissions (60%) and 6 partial responses (40%). Because of the high toxicity rate, in a subsequent study (group B: n = 30; 23 mean, 7 women; median age 66 years) the EBRT scheme was changed using smaller fractions (2.0 Gy) to reach the same total dose of 40 Gy. The complication rate (17%) was significantly reduced, while the overall response remained excellent (83%): 17 complete and 8 partial responses. The impressive change in complication rate of HDR brachytherapy and EBRT stresses the impact of the fraction per dose and illustrates the small therapeutic margins. (author)

  19. Modulation of toxicity following external beam irradiation preceded by high-dose rate brachytherapy in inoperable oesophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Taal, B.G.; Aleman, B.M.P.; Koning, C.C.E.; Boot, H. [Nederlands Kanker Inst. `Antoni van Leeuwenhoekhuis`, Amsterdam (Netherlands)

    1996-09-01

    To induce fast relief of dysphagia in inoperable oesephageal cancer, we applied high-dose rate (HDR) intraluminal irradiation followed by external irradiation (EBRT) in a phase II study. 15 patients (group A: n = 15; 10 men, 5 women; median age 66 years) were treated with 10 Gy HDR brachytherapy plus 40 Gy EBRT (15 fractions of 2.67 Gy). Severe side-effects were encountered in 60% of patients: 3 late ulceration, 2 pending fistula and 2 patients with fatal haemorrhage after an interval of 6 months. Overall response was excellent: 9 complete remissions (60%) and 6 partial responses (40%). Because of the high toxicity rate, in a subsequent study (group B: n = 30; 23 mean, 7 women; median age 66 years) the EBRT scheme was changed using smaller fractions (2.0 Gy) to reach the same total dose of 40 Gy. The complication rate (17%) was significantly reduced, while the overall response remained excellent (83%): 17 complete and 8 partial responses. The impressive change in complication rate of HDR brachytherapy and EBRT stresses the impact of the fraction per dose and illustrates the small therapeutic margins. (author).

  20. Effective Equivalent Doses of External Irradiation of Population by Man-made Radionuclides from the Soil in the Sarajevo Region Over the Period of 1986-1989

    International Nuclear Information System (INIS)

    Saracevic, L.; Samek, D.; Hasanbasic, D.; Gradascevic, N.

    1998-01-01

    Assessment of exposition of human body to radioactive materials is seen as radiation-hygienic measure of utmost importance, since the doses absorbed due to radionuclides present in soil, air, food and water are significant integral parts of the total dose that the human being receives in all kinds and conditions of exposition. External irradiation by radionuclides deposed in soil is a major contributor to the whole dose of irradiation of population. Assuming that fission radionuclides Cs-134 and Cs-137 had a specially significant contribution to the total dose of irradiation of the population over the investigation period (1986-1989), we established their levels of activity in the soil in different localities of the Sarajevo region, and then calculated the effective equivalent dose for the population for each year of investigation. The mean values for the yearly effective equivalent doses of external irradiation of the population by fission radionuclides Cs-134 and Cs-137 from the soil in the Sarajevo region were 0.77 mSv/year in 1989. Contribution by Cs-134 to the total effective equivalent dose was 63.64 % in 1986 year, to be reeducated in 1987 to 45.67 %, in 1988 to 35.89 % and in the year 1989 to 33.33 %. The effective equivalent dose was different to a great extent by the investigated localities (town sections) during the started period. It can be inferred from the above that the average population of the Sarajevo region did not receive a larger dose of radiation than the one established by the International Commission for Radiological Protection as the limit for subsequent exposition to radiation. (author)

  1. Low-dose total skin electron beam therapy for cutaneous lymphoma : Minimal risk of acute toxicities.

    Science.gov (United States)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor

    2017-12-01

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T‑cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses.

  2. Determination of the total indicative dose in drinking and mineral waters

    International Nuclear Information System (INIS)

    Flesch, K.; Schulz, H.; Knappik, R.; Koehler, M.

    2006-01-01

    In Europe and Germany administrative regulations exist for the surveillance of the total indicative dose of water supplied for human consumption. This parameter, which cannot be analyzed directly, has to be calculated using nuclide specific activity concentration and age specific dose conversion factors and consumption rates. Available calculation methods differ regarding the used radionuclides, consumption rates and whether they use age specific dose conversion factors or not. In Germany administrative guidelines for the determination of the total indicative dose are still not available. As they have analyzed a large number of waters in the past, the authors derive a praxis orientated concept for the determination of the total indicative dose which respects radiological, analytical and hydrochemical aspects as well. Finally it is suggested to handle sparkling waters in the same manner as drinking waters. (orig.)

  3. Simulation of Shielding Effects on the Total Dose Observed in TDE of KISAT-1

    Directory of Open Access Journals (Sweden)

    Sung-Joon Kim

    2001-06-01

    Full Text Available The threshold voltage shift observed in TDE (Total Dose Experiment on board the KITSAT-1 is converted into dose (rad(SiO2 usinsg the result of laboratory calibration with Co-60 gamma ray source in KAERI (Korea Atomic Energy Research Institute. Simulation using the NASA radiation model of geomagnetosphere verifies that the dose difference between RADFET1 and RADFET3 observed on KITSAT-1 comes from the difference in shielding thickness at the position of these RADFETs.

  4. High-dose external beam irradiation inhibits neointima formation in stented pig coronary arteries

    International Nuclear Information System (INIS)

    Verheye, Stefan; Coussement, Patrick K.; Salame, Mahomed Y.; Fallahi, Payam; Cui Jianhua; Chronos, Nicolas A.F.; King, Spencer B.; Crocker, Ian R.; Robinson, Keith A.

    2001-01-01

    Purpose: To evaluate high-dose external beam irradiation (EBRT) in a pig coronary stent preparation because low and intermediate-dose EBRT failed to show inhibition of neointima formation in stented animal models. Methods and Materials: Thirty-five stents were implanted in the coronary arteries of 17 pigs. Seven pigs were exposed to a single dose of 21 Gy EBRT immediately after stenting. Ten stented, nonirradiated pigs served as controls. After 4 weeks, the study arteries and myocardium were examined by light and scanning electron microscopy. Results: Compared with controls, 21 Gy EBRT resulted in a larger lumen area (7.57±1.67 mm 2 vs. 4.00±1.63 mm 2 , p 2 vs. 3.36±2.26 mm 2 , p<0.001) and a smaller maximal intimal thickness (0.16±0.09 mm vs. 0.68±0.31 mm, p<0.001). Unresorbed intramural hemorrhages and adherent mural thrombi were present in the irradiated vessels, which also showed incomplete re-endothelialization. The irradiated hearts demonstrated diffuse interstitial and perivascular inflammation and fibrosis. Conclusions: EBRT at 21 Gy to the entire heart significantly inhibited neointima formation in stented pig coronary arteries but also resulted in incomplete re-endothelialization, myocardial inflammation, and fibrosis. Improvements in localization and delivery techniques are required to allow clinical implementation of this technique

  5. Effect of γ-dose rate and total dose interrelation on the polymeric hydrogel: A novel injectable male contraceptive

    International Nuclear Information System (INIS)

    Jha, Pradeep K.; Jha, Rakhi; Gupta, B.L.; Guha, Sujoy K.

    2010-01-01

    Functional necessity to use a particular range of dose rate and total dose of γ-initiated polymerization to manufacture a novel polymeric hydrogel RISUG (reversible inhibition of sperm under guidance) made of styrene maleic anhydride (SMA) dissolved in dimethyl sulphoxide (DMSO), for its broad biomedical application explores new dimension of research. The present work involves 16 irradiated samples. They were tested by fourier transform infrared spectroscopy, matrix assisted laser desorption/ionization-TOF, field emission scanning electron microscopy, high resolution transmission electron microscopy, etc. to see the interrelation effect of gamma dose rates (8.25, 17.29, 20.01 and 25.00 Gy/min) and four sets of doses (1.8, 2.0, 2.2 and 2.4 kGy) on the molecular weight, molecular weight distribution and porosity analysis of the biopolymeric drug RISUG. The results of randomized experiment indicated that a range of 18-24 Gy/min γ-dose rate and 2.0-2.4 kGy γ-total doses is suitable for the desirable in vivo performance of the contraceptive copolymer.

  6. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  7. Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA GSFC and NEPP

    Science.gov (United States)

    Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Label, Kenneth A.; Cochran, Donna J.; O'Bryan, Martha V.

    2017-01-01

    Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include opto-electronics, digital, analog, linear bipolar devices, and hybrid devices.

  8. Recent Total Ionizing Dose and Displacement Damage Compendium of Candidate Electronics for NASA Space Systems

    Science.gov (United States)

    Cochran, Donna J.; Boutte, Alvin J.; Campola, Michael J.; Carts, Martin A.; Casey, Megan C.; Chen, Dakai; LaBel, Kenneth A.; Ladbury, Raymond L.; Lauenstein, Jean-Marie; Marshall, Cheryl J.; hide

    2011-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.

  9. The Role of Electron Transport and Trapping in MOS Total-Dose Modeling

    International Nuclear Information System (INIS)

    Flament, O.; Fleetwood, D.M.; Leray, J.L.; Paillet, P.; Riewe, L.C.; Winokur, P.S.

    1999-01-01

    Deep and shallow electron traps form in irradiated thermal SiO 2 as a natural response to hole transport and trapping. The density and stability of these defects are discussed, as are their implications for total-dose modeling

  10. Total dose effects on the matching properties of deep submicron MOS transistors

    International Nuclear Information System (INIS)

    Wang Yuxin; Hu Rongbin; Li Ruzhang; Chen Guangbing; Fu Dongbing; Lu Wu

    2014-01-01

    Based on 0.18 μm MOS transistors, for the first time, the total dose effects on the matching properties of deep submicron MOS transistors are studied. The experimental results show that the total dose radiation magnifies the mismatch among identically designed MOS transistors. In our experiments, as the radiation total dose rises to 200 krad, the threshold voltage and drain current mismatch percentages of NMOS transistors increase from 0.55% and 1.4% before radiation to 17.4% and 13.5% after radiation, respectively. PMOS transistors seem to be resistant to radiation damage. For all the range of radiation total dose, the threshold voltage and drain current mismatch percentages of PMOS transistors keep under 0.5% and 2.72%, respectively. (semiconductor devices)

  11. Analysis of Surface Dose Refer to Distance between Beam Spoiler and Patient in Total Body Irradiation

    International Nuclear Information System (INIS)

    Choi, Jong Hwan; Kim, Jong Sik; Choi, Ji Min; Shin, Eun Hyuk; Song, Ki Won; Park, Young Hwan

    2007-01-01

    Total body irradiation is used to kill the total malignant cell and for immunosuppression component of preparatory regimens for bone-marrow restitution of patients. Beam spoiler is used to increase the dose to the superficial tissues. This paper finds the property of the distance between beam spoiler and patient. Set-up conditions are 6 MV-Xray, 300 MU, SAD = 400 cm, field size = 40 x 40 cm 2 . The parallel plate chamber located in surface, midpoint and exit of solid water phantom. The surface dose is measured while the distance between beam spoiler and patient is altered. Because it should be found proper distance. The solid water phantom is fixer and beam spoiler is moving. Central dose of phantom is 10.7 cGy and exit dose is 6.7 cGy. In case of distance of 50 cm to 60 cm between beam spoiler and solid water phantom, incidence dose is 14.58-14.92 cGy. Therefore, The surface dose was measured 99.4-101% with got near most to the prescription dose. In clinical case, distance between beam spoiler and patient affect surface dose. If once 50-60 cm of distance between beam spoiler and patient, surface dose of patient got near prescription dose. It would be taken distance between beam spoiler and patient into account in clinical therapy.

  12. Estimation of the dose distribution within, and total dose to, the body of an acutely overexposed person

    International Nuclear Information System (INIS)

    Beer, G.P. de; Feather, J.I.; Oude, A. de; Language, A.E.

    1981-01-01

    In a case of accidental overexposure of a person, it is important to obtain a reliable value of the whole body dose as well as of the dose distribution within the body. Any follow-up treatment based only on the clinical effects as and when they appear, may result in insufficient or even erroneous therapy. In this respect knowledge of total dose and its distribution within the body may be a valuable aid in deciding on the follow-up treatment, taking into account the latent nature of the clinical effects. The calculated whole body dose and its distribution within the body of a person overexposed to a 192 Ir radiography source, are compared to experimentally determined values. In both cases the calculated values prove to be of sufficient accuracy to serve as an aid in decisions on the follow-up treatment. (author)

  13. Low-dose-rate total lymphoid irradiation: a new method of rapid immunosuppression

    International Nuclear Information System (INIS)

    Blum, J.E.; de Silva, S.M.; Rachman, D.B.; Order, S.E.

    1988-01-01

    Total Lymphoid Irradiation (TLI) has been successful in inducing immunosuppression in experimental and clinical applications. However, both the experimental and clinical utility of TLI are hampered by the prolonged treatment courses required (23 days in rats and 30-60 days in humans). Low-dose-rate TLI has the potential of reducing overall treatment time while achieving comparable immunosuppression. This study examines the immunosuppressive activity and treatment toxicity of conventional-dose-rate (23 days) vs low-dose-rate (2-7 days) TLI. Seven groups of Lewis rats were given TLI with 60Co. One group was treated at conventional-dose-rates (80-110 cGy/min) and received 3400 cGy in 17 fractions over 23 days. Six groups were treated at low-dose-rate (7 cGy/min) and received total doses of 800, 1200, 1800, 2400, 3000, and 3400 cGy over 2-7 days. Rats treated at conventional-dose-rates over 23 days and at low-dose-rate over 2-7 days tolerated radiation with minimal toxicity. The level of immunosuppression was tested using allogeneic (Brown-Norway) skin graft survival. Control animals retained allogeneic skin grafts for a mean of 14 days (range 8-21 days). Conventional-dose-rate treated animals (3400 cGy in 23 days) kept their grafts 60 days (range 50-66 days) (p less than .001). Low-dose-rate treated rats (800 to 3400 cGy total dose over 2-7 days) also had prolongation of allogeneic graft survival times following TLI with a dose-response curve established. The graft survival time for the 3400 cGy low-dose-rate group (66 days, range 52-78 days) was not significantly different from the 3400 cGy conventional-dose-rate group (p less than 0.10). When the total dose given was equivalent, low-dose-rate TLI demonstrated an advantage of reduced overall treatment time compared to conventional-dose-rate TLI (7 days vs. 23 days) with no increase in toxicity

  14. Knowledge-based prediction of three-dimensional dose distributions for external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Shiraishi, Satomi; Moore, Kevin L., E-mail: kevinmoore@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California 92093 (United States)

    2016-01-15

    Purpose: To demonstrate knowledge-based 3D dose prediction for external beam radiotherapy. Methods: Using previously treated plans as training data, an artificial neural network (ANN) was trained to predict a dose matrix based on patient-specific geometric and planning parameters, such as the closest distance (r) to planning target volume (PTV) and organ-at-risks (OARs). Twenty-three prostate and 43 stereotactic radiosurgery/radiotherapy (SRS/SRT) cases with at least one nearby OAR were studied. All were planned with volumetric-modulated arc therapy to prescription doses of 81 Gy for prostate and 12–30 Gy for SRS. Using these clinically approved plans, ANNs were trained to predict dose matrix and the predictive accuracy was evaluated using the dose difference between the clinical plan and prediction, δD = D{sub clin} − D{sub pred}. The mean (〈δD{sub r}〉), standard deviation (σ{sub δD{sub r}}), and their interquartile range (IQR) for the training plans were evaluated at a 2–3 mm interval from the PTV boundary (r{sub PTV}) to assess prediction bias and precision. Initially, unfiltered models which were trained using all plans in the cohorts were created for each treatment site. The models predict approximately the average quality of OAR sparing. Emphasizing a subset of plans that exhibited superior to the average OAR sparing during training, refined models were created to predict high-quality rectum sparing for prostate and brainstem sparing for SRS. Using the refined model, potentially suboptimal plans were identified where the model predicted further sparing of the OARs was achievable. Replans were performed to test if the OAR sparing could be improved as predicted by the model. Results: The refined models demonstrated highly accurate dose distribution prediction. For prostate cases, the average prediction bias for all voxels irrespective of organ delineation ranged from −1% to 0% with maximum IQR of 3% over r{sub PTV} ∈ [ − 6, 30] mm. The

  15. Knowledge-based prediction of three-dimensional dose distributions for external beam radiotherapy

    International Nuclear Information System (INIS)

    Shiraishi, Satomi; Moore, Kevin L.

    2016-01-01

    Purpose: To demonstrate knowledge-based 3D dose prediction for external beam radiotherapy. Methods: Using previously treated plans as training data, an artificial neural network (ANN) was trained to predict a dose matrix based on patient-specific geometric and planning parameters, such as the closest distance (r) to planning target volume (PTV) and organ-at-risks (OARs). Twenty-three prostate and 43 stereotactic radiosurgery/radiotherapy (SRS/SRT) cases with at least one nearby OAR were studied. All were planned with volumetric-modulated arc therapy to prescription doses of 81 Gy for prostate and 12–30 Gy for SRS. Using these clinically approved plans, ANNs were trained to predict dose matrix and the predictive accuracy was evaluated using the dose difference between the clinical plan and prediction, δD = D clin − D pred . The mean (〈δD r 〉), standard deviation (σ δD r ), and their interquartile range (IQR) for the training plans were evaluated at a 2–3 mm interval from the PTV boundary (r PTV ) to assess prediction bias and precision. Initially, unfiltered models which were trained using all plans in the cohorts were created for each treatment site. The models predict approximately the average quality of OAR sparing. Emphasizing a subset of plans that exhibited superior to the average OAR sparing during training, refined models were created to predict high-quality rectum sparing for prostate and brainstem sparing for SRS. Using the refined model, potentially suboptimal plans were identified where the model predicted further sparing of the OARs was achievable. Replans were performed to test if the OAR sparing could be improved as predicted by the model. Results: The refined models demonstrated highly accurate dose distribution prediction. For prostate cases, the average prediction bias for all voxels irrespective of organ delineation ranged from −1% to 0% with maximum IQR of 3% over r PTV ∈ [ − 6, 30] mm. The average prediction error was less

  16. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    International Nuclear Information System (INIS)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor; Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette

    2017-01-01

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D mean ), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D mean was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m 2 , with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D mean exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [de

  17. Xerostomia after radiotherapy. What matters - mean total dose or dose to each parotid gland?

    International Nuclear Information System (INIS)

    Tribius, S.; Sommer, J.; Prosch, C.; Bajrovic, A.; Kruell, A.; Petersen, C.; Muenscher, A.; Blessmann, M.; Todorovic, M.; Tennstedt, P.

    2013-01-01

    Purpose: Xerostomia is a debilitating side effect of radiotherapy in patients with head and neck cancer. We undertook a prospective study of the effect on xerostomia and outcomes of sparing one or both parotid glands during radiotherapy for patients with squamous cell carcinoma of the head and neck. Methods and materials: Patients with locally advanced squamous cell carcinoma of the head and neck received definitive (70 Gy in 2 Gy fractions) or adjuvant (60-66 Gy in 2 Gy fractions) curative-intent radiotherapy using helical tomotherapy with concurrent chemotherapy if appropriate. Group A received < 26 Gy to the left and right parotids and group B received < 26 Gy to either parotid. Results: The study included 126 patients; 114 (55 in group A and 59 in group B) had follow-up data. There were no statistically significant differences between groups in disease stage. Xerostomia was significantly reduced in group A vs. group B (p = 0.0381). Patients in group A also had significantly less dysphagia. Relapse-free and overall survival were not compromised in group A: 2-year relapse-free survival was 86% vs. 72% in group B (p = 0.361); 2-year overall survival was 88% and 76%, respectively (p = 0.251). Conclusion: This analysis suggests that reducing radiotherapy doses to both parotid glands to < 26 Gy can reduce xerostomia and dysphagia significantly without compromising survival. Sparing both parotids while maintaining target volume coverage and clinical outcome should be the treatment goal and reporting radiotherapy doses delivered to the individual parotids should be standard practice. (orig.)

  18. Xerostomia after radiotherapy. What matters - mean total dose or dose to each parotid gland?

    Energy Technology Data Exchange (ETDEWEB)

    Tribius, S.; Sommer, J.; Prosch, C.; Bajrovic, A.; Kruell, A.; Petersen, C. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Radiation Oncology; Muenscher, A. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Otorhinolaryngology and Head and Neck Surgery; Blessmann, M. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Oral and Maxillofacial Surgery; Todorovic, M. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Medical Physics; Tennstedt, P. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Martini-Clinic, Prostate Cancer Center

    2013-03-15

    Purpose: Xerostomia is a debilitating side effect of radiotherapy in patients with head and neck cancer. We undertook a prospective study of the effect on xerostomia and outcomes of sparing one or both parotid glands during radiotherapy for patients with squamous cell carcinoma of the head and neck. Methods and materials: Patients with locally advanced squamous cell carcinoma of the head and neck received definitive (70 Gy in 2 Gy fractions) or adjuvant (60-66 Gy in 2 Gy fractions) curative-intent radiotherapy using helical tomotherapy with concurrent chemotherapy if appropriate. Group A received < 26 Gy to the left and right parotids and group B received < 26 Gy to either parotid. Results: The study included 126 patients; 114 (55 in group A and 59 in group B) had follow-up data. There were no statistically significant differences between groups in disease stage. Xerostomia was significantly reduced in group A vs. group B (p = 0.0381). Patients in group A also had significantly less dysphagia. Relapse-free and overall survival were not compromised in group A: 2-year relapse-free survival was 86% vs. 72% in group B (p = 0.361); 2-year overall survival was 88% and 76%, respectively (p = 0.251). Conclusion: This analysis suggests that reducing radiotherapy doses to both parotid glands to < 26 Gy can reduce xerostomia and dysphagia significantly without compromising survival. Sparing both parotids while maintaining target volume coverage and clinical outcome should be the treatment goal and reporting radiotherapy doses delivered to the individual parotids should be standard practice. (orig.)

  19. Gamma-ray dose-rates to human tissues from natural external sources in Great Britain

    International Nuclear Information System (INIS)

    Spiers, F.W.

    1960-01-01

    The information on environmental gamma radiation given in the last report (Spiers, 1956) was limited by the small amount of experimental data then available. Considerably more information has been accumulated since then and a summary has been published in the Report of the United Nations Scientific Committee on te Effects of Atomic Radiation 1958). The data reported from Austria, France, Sweden and the U.S.A. show that in general dose-rates out-of-doors range from about 0 mrads per year over sedimentary rocks to about 200 mrads per year in granite districts. In houses a similar range of doserates is indicated, the rates in individual houses depending upon the nature of the building materials. In some parts of the world, however, very much higher dose-rates have been observed. On the extensive area of monazite sand in the Kerala State of India dose-rates of up to 4000 mrads per year have been recorded and the mean dose-rate for 10 villages with a total population of 52,000 has been estimated to be 1270 mrads per year. Mean dose-rates of 500 and 1600 mrads per year have also been reported from two localities in Brazil

  20. Gamma-ray dose-rates to human tissues from natural external sources in Great Britain

    Energy Technology Data Exchange (ETDEWEB)

    Spiers, F W

    1960-12-01

    The information on environmental gamma radiation given in the last report (Spiers, 1956) was limited by the small amount of experimental data then available. Considerably more information has been accumulated since then and a summary has been published in the Report of the United Nations Scientific Committee on te Effects of Atomic Radiation 1958). The data reported from Austria, France, Sweden and the U.S.A. show that in general dose-rates out-of-doors range from about 0 mrads per year over sedimentary rocks to about 200 mrads per year in granite districts. In houses a similar range of doserates is indicated, the rates in individual houses depending upon the nature of the building materials. In some parts of the world, however, very much higher dose-rates have been observed. On the extensive area of monazite sand in the Kerala State of India dose-rates of up to 4000 mrads per year have been recorded and the mean dose-rate for 10 villages with a total population of 52,000 has been estimated to be 1270 mrads per year. Mean dose-rates of 500 and 1600 mrads per year have also been reported from two localities in Brazil.

  1. Sensitivity of total stress to changes in externally applied water pressure in KBS-3 buffer bentonite

    International Nuclear Information System (INIS)

    Harrington, J.F.; Birchall, D.J.

    2007-04-01

    In the current Swedish repository design concept, composite copper and steel canisters containing spent nuclear fuel will be placed in large diameter disposal boreholes drilled into the floor of the repository tunnels. The space around each canister will be filled with pre-compacted bentonite which over time will draw in the surrounding ground water and swell, closing up any construction joints. However, for the purposes of performance assessment, it is necessary to consider the effect of glacial loading of a future repository and its impact on the mechanical behaviour of the bentonite, in particular, the sensitivity of total stress to changes in porewater pressure (backpressure). Two experimental histories have been undertaken using a custom-designed constant volume and radial flow (CVRF) apparatus. In both tests backpressure was varied in a number of incremental and decremental cycles while total stress, porewater pressure and volumetric flow rate were continuously monitored. The swelling pressure of the buffer clay at dry densities of 1.8 Mg/m 3 and 1.61 Mg/m 3 was determined to be around 5.5 MPa and 7.2 MPa respectively. For initial ascending porewater pressure histories the average proportionality factor α ranged from 0.86 and 0.92. Data exhibited a general trend of increasing α with increasing backpressure. In test Mx80-11 this was supported by analysis of the water inflow data which indicated a reduction in system compressibility. Asymptotic values of porewater pressure within the clay are in good agreement with externally applied backpressure values. Inspection of data provides no evidence for the development of hydraulic thresholds within the clay, subject to the boundary conditions of this test geometry. Analysis of the stress data demonstrates significant hysteresis between ascending and descending porewater pressure histories. The amount of hysteresis appears to be linked to the magnitude of the backpressure applied to the specimen, suggesting some

  2. Sensitivity of total stress to changes in externally applied water pressure in KBS-3 buffer bentonite

    Energy Technology Data Exchange (ETDEWEB)

    Harrington, J.F.; Birchall, D.J. [British Geological Survey, Chemical and Biological Hazards Programme, Kingsley Dunham Centre (United Kingdom)

    2007-04-15

    In the current Swedish repository design concept, composite copper and steel canisters containing spent nuclear fuel will be placed in large diameter disposal boreholes drilled into the floor of the repository tunnels. The space around each canister will be filled with pre-compacted bentonite which over time will draw in the surrounding ground water and swell, closing up any construction joints. However, for the purposes of performance assessment, it is necessary to consider the effect of glacial loading of a future repository and its impact on the mechanical behaviour of the bentonite, in particular, the sensitivity of total stress to changes in porewater pressure (backpressure). Two experimental histories have been undertaken using a custom-designed constant volume and radial flow (CVRF) apparatus. In both tests backpressure was varied in a number of incremental and decremental cycles while total stress, porewater pressure and volumetric flow rate were continuously monitored. The swelling pressure of the buffer clay at dry densities of 1.8 Mg/m{sup 3} and 1.61 Mg/m{sup 3} was determined to be around 5.5 MPa and 7.2 MPa respectively. For initial ascending porewater pressure histories the average proportionality factor {alpha} ranged from 0.86 and 0.92. Data exhibited a general trend of increasing {alpha} with increasing backpressure. In test Mx80-11 this was supported by analysis of the water inflow data which indicated a reduction in system compressibility. Asymptotic values of porewater pressure within the clay are in good agreement with externally applied backpressure values. Inspection of data provides no evidence for the development of hydraulic thresholds within the clay, subject to the boundary conditions of this test geometry. Analysis of the stress data demonstrates significant hysteresis between ascending and descending porewater pressure histories. The amount of hysteresis appears to be linked to the magnitude of the backpressure applied to the specimen

  3. Estimation of the total absorbed dose by quartz in retrospective conditions

    International Nuclear Information System (INIS)

    Correcher, V.; Delgado, A.

    2003-01-01

    The estimation of the total absorbed dose is of great interest in areas affected by a radiological accident when no conventional dosimetric systems are available. This paper reports about the usual methodology employed in dose reconstruction from the thermoluminescence (TL) properties of natural quartz, extracted from selected ceramic materials (12 bricks) picked up in the Chernobyl area. It has been possible to evaluate doses under 50mGy after more than 11 years later since the radiological accident happened. The main advance of this fact is the reduction of the commonly accepted limit dose estimation more than 20 times employing luminescence methods. (Author) 11 refs

  4. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  5. Conventional and conformal technique of external beam radiotherapy in locally advanced cervical cancer: Dose distribution, tumor response, and side effects

    Science.gov (United States)

    Mutrikah, N.; Winarno, H.; Amalia, T.; Djakaria, M.

    2017-08-01

    The objective of this study was to compare conventional and conformal techniques of external beam radiotherapy (EBRT) in terms of the dose distribution, tumor response, and side effects in the treatment of locally advanced cervical cancer patients. A retrospective cohort study was conducted on cervical cancer patients who underwent EBRT before brachytherapy in the Radiotherapy Department of Cipto Mangunkusumo Hospital. The prescribed dose distribution, tumor response, and acute side effects of EBRT using conventional and conformal techniques were investigated. In total, 51 patients who underwent EBRT using conventional techniques (25 cases using Cobalt-60 and 26 cases using a linear accelerator (LINAC)) and 29 patients who underwent EBRT using conformal techniques were included in the study. The distribution of the prescribed dose in the target had an impact on the patient’s final response to EBRT. The complete response rate of patients to conformal techniques was significantly greater (58%) than that of patients to conventional techniques (42%). No severe acute local side effects were seen in any of the patients (Radiation Therapy Oncology Group (RTOG) grades 3-4). The distribution of the dose and volume to the gastrointestinal tract affected the proportion of mild acute side effects (RTOG grades 1-2). The urinary bladder was significantly greater using conventional techniques (Cobalt-60/LINAC) than using conformal techniques at 72% and 78% compared to 28% and 22%, respectively. The use of conformal techniques in pelvic radiation therapy is suggested in radiotherapy centers with CT simulators and 3D Radiotherapy Treatment Planning Systems (RTPSs) to decrease some uncertainties in radiotherapy planning. The use of AP/PA pelvic radiation techniques with Cobalt-60 should be limited in body thicknesses equal to or less than 18 cm. When using conformal techniques, delineation should be applied in the small bowel, as it is considered a critical organ according to RTOG

  6. Uterine cervix cancer treatment in IIB, IIIA and IIIB stages with external radiotherapy versus external radiotherapy and scintiscanning of low dose. ION SOLCA. Years 1998-2000

    International Nuclear Information System (INIS)

    Sanchez, Doris; Falquez, Roberto

    2002-01-01

    We realized study of retrospective accomplished in course of years 1998-2000, reviewing clinical charts of statistical department of ION SOLCA. We reviewed 544 cases in 1998, 603 patients in 1999, and 630 cases in 2000. In the radiotherapy service, 133 patients received treatment with external radiotherapy between February 1998 to February 1999 in IIB, IIIA, IIIB stages and only 80 patients were treated with external radiotherapy and scintiscanning of low dose rate in the same stages between March 1999 to March 2000. (The author)

  7. Single event effects and total ionizing dose effects of typical VDMOSFET devices

    International Nuclear Information System (INIS)

    Lou Jianshe; Cai Nan; Liu Jiaxin; Wu Qinzhi; Wang Jia

    2012-01-01

    In this work, single event effects and total ionizing dose effects of typical VDMOSFET irradiated by 60 Co γ-rays and 252 Cf source were studied. The single event burnout and single event gate rupture (SEB/SEGR) effects were investigated, and the relationship between drain-source breakdown voltage and ionizing dose was obtained. The results showed that the VDMOSFET devices were sensitive to SEB and SEGR, and measures to improve their resistance to SEB and SEGR should be considered seriously for their space applications. The drain-source breakdown voltage was sensitive to total ionizing dose effects as the threshold voltage. In assessing the devices' resistance to the total ionizing dose effects, both the threshold voltage and the drain-source breakdown voltage should be taken into account. (authors)

  8. Serum protein concentration in low-dose total body irradiation of normal and malnourished rats

    International Nuclear Information System (INIS)

    Viana, W.C.M.; Lambertz, D.; Borges, E.S.; Neto, A.M.O.; Lambertz, K.M.F.T.; Amaral, A.

    2016-01-01

    Among the radiotherapeutics' modalities, total body irradiation (TBI) is used as treatment for certain hematological, oncological and immunological diseases. The aim of this study was to evaluate the long-term effects of low-dose TBI on plasma concentration of total protein and albumin using prematurely and undernourished rats as animal model. For this, four groups with 9 animals each were formed: Normal nourished (N); Malnourished (M); Irradiated Normal nourished (IN); Irradiated Malnourished (IM). At the age of 28 days, rats of the IN and IM groups underwent total body gamma irradiation with a source of cobalt-60. Total protein and Albumin in the blood serum was quantified by colorimetry. This research indicates that procedures involving low-dose total body irradiation in children have repercussions in the reduction in body-mass as well as in the plasma levels of total protein and albumin. Our findings reinforce the periodic monitoring of total serum protein and albumin levels as an important tool in long-term follow-up of pediatric patients in treatments associated to total body irradiation. - Highlights: • Low-dose total body irradiation (TBI) in children have repercussions in their body-mass. • Long-term total protein and albumin levels are affected by TBI. • The monitoring of total protein and albumin levels are useful in the follow-up of TBI pediatric patients.

  9. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    International Nuclear Information System (INIS)

    Endo, Akira; Petoussi-Henss, Nina; Zankl, Maria; Schlattl, Helmut; Bolch, Wesley E.; Eckerman, Keith F.; Hertel, Nolan E.; Hunt, John G.; Pelliccioni, Maurizio; Menzel, Hans-Georg

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors. This paper briefly reviews the reference computational phantoms and dose conversion coefficients for external exposures that were published jointly by ICRP and ICRU. Both these publications appeared as a consequence of the ICRP 2007 Recommendations; to implement these recommendations, the ICRP has developed reference computational phantoms representing the adult male and female. These phantoms are used to calculate reference dose conversion coefficients for external and internal sources. Using the reference phantoms and methodology consistent with the 2007 Recommendations, dose conversion coefficients for both effective doses and organ-absorbed doses for various types of idealised external exposures have been calculated. These data sets supersede the existing ICRP/ICRU data sets and expand the particle types and energy ranges. For neutrons, the new effective dose conversion coefficients become smaller compared with those in ICRP74, for energies below hundreds of keV. This is mainly

  10. Treatment of locally advanced breast carcinoma with high-dose external beam supervoltage radiotherapy

    International Nuclear Information System (INIS)

    Brufman, G.; Weshler, Z.; Prosnitz, L.R.; Fuks, Z.

    1981-01-01

    Between 1960 and 1978, 87 patients with locally advanced Tsub(3-4)Nsub(0-3)M 0 carcinoma of the breast were treated with 5,000 to 8,000 rad of external beam supervoltage radiotherapy. Initial clinical eradication of the tumour was observed in 76 of 87 cases (87%), but the actuarial probability of local control at 5 yr was only 53%. Furthermore, the actuarial probability of disease-free survival was 25% at 5 yr and 13% at 10 yr. Most of the patients eventually succumbed to metastatic breast carcinoma and the actuarial survival at 5 yr was 43% and at 10 yr, 16%. The addition of adjuvant low-dose chemotherapy, given to 13 patients, did not affect the rates of local control, survival or disease-free survival. The most common long-term complication was extensive and deforming radiation-induced fibrosis of the treated breast. The actuarial probability of 10-yr survival without a local recurrence and without severe fibrosis of the treated breast was only 17.5%. The role of adjuvant high-dose chemotherapy in the treatment of locally advanced breast carcinoma and the possible use of improved radiotherapy techniques to achieve a more effective long-term local control and a more desirable cosmetic end result are discussed. (author)

  11. Phantom study of radiation doses outside the target volume brachytherapy versus external radiotherapy of early breast cancer

    International Nuclear Information System (INIS)

    Johansson, Bengt; Persson, Essie; Westman, Gunnar; Persliden, Jan

    2003-01-01

    Background and purpose: Brachytherapy is sometimes suggested as an adjuvant treatment after surgery of some tumours. When introducing this, it would be useful to have an estimate of the dose distribution to different body sites, both near and distant to target, comparing conventional external irradiation to brachytherapy. The aim of the present study was to determine radiation doses with both methods at different body sites, near and distant to target, in an experimental situation on an operated left sided breast cancer on a female Alderson phantom. Methods: Five external beam treatments with isocentric tangential fields were given by a linear accelerator. A specified dose of 1.0 Gy was given to the whole left sided breast volume. Five interstitial brachytherapy treatments were given to the upper, lateral quadrant of the left breast by a two plane, 10 needles implant. A dose of 1.0 Gy specified according to the Paris system was administered by a pulsed dose rate afterloading machine. Absorbed dose in different fixed dose points were measured by thermoluminescence dosimeters. Results: Both methods yielded an absorbed dose of the same size to the bone marrow and internal organs distant to target, 1.0-1.4% of the prescribed dose. There was a trend of lower doses to the lower half of the trunk and higher doses to the upper half of the trunk, respectively, by brachytherapy. A 90% reduction of absorbed dose with brachytherapy compared to external irradiation was found in the near-target region within 5 cm from target boundary where parts of the left lung and the heart are situated. If an adjuvant dose of 50 Gy is given with the external radiotherapy and brachytherapy, the absorbed dose in a part of the myocardium could be reduced from 31.8 to 2.1 Gy. Conclusions: Near target, brachytherapy yielded a considerably lower absorbed dose which is of special importance when considering radiation effects on the myocard and lungs. We could not demonstrate any difference of

  12. Dose characteristics of total-skin electron-beam irradiation with six-dual electron fields

    International Nuclear Information System (INIS)

    Choi, Tae Jin; Kim, Jin Hee; Kim, Ok Bae

    1998-01-01

    To obtain the uniform dose at limited depth to entire surface of the body, the dose characteristics of degraded electron beam of the large target-skin distance and the dose distribution of the six-dual electron fields were investigated. The experimental dose distributions included the depth dose curve, spatial dose and attenuated electron beam were determined with 300 cm of Target-Skin Distance (TSD) and full collimator size (35x35 cm 2 on TSD 100 cm) in 4 MeV electron beam energy. Actual collimated field size of 105 cmx105 cm at the distance of 300 cm could include entire hemibody. A patient was standing on step board with hands up and holding the pole to stabilize his/her positions for the six-dual fields technique. As a scatter-degrader, 0.5 cm of acrylic plate was inserted at 20 cm from the body surface on the electron beam path to induce ray scattering and to increase the skin dose. The Full Width at Half Maximum(FWHM) of dose profile was 130 cm in large field of 105x105 cm 2 . The width of 100±10% of the resultant dose from two adjacent fields which were separated at 25 cm from field edge for obtaining the dose uniformity was extended to 186 cm. The depth of maximum dose lies at 5 mm and the 80% depth dose lies between 7 and 8 mm for the degraded electron beam by using the 0.5 cm thickness of acrylic absorber. Total skin electron beam irradiation (TSEBI) was carried out using the six dual fields has been developed at Stanford University. The dose distribution in TSEBI showed relatively uniform around the flat region of skin except the protruding and deeply curvatured portion of the body, which showed excess of dose at the former and less dose at the latter. The percent depth dose, profile curves and superimposed dose distribution were investigated using the degraded using the degraded electron beam through the beam absorber. The dose distribution obtained by experiments of TSEBI showed within±10% difference excepts the protruding area of skin which needs a

  13. Dose conversion coefficients based on the Chinese mathematical phantom and MCNP code for external photon irradiation

    International Nuclear Information System (INIS)

    Qiu, R.; Li, J.; Zhang, Z.; Liu, L.; Bi, L.; Ren, L.

    2009-01-01

    A set of conversion coefficients from kerma free-in-air to the organ-absorbed dose are presented for external monoenergetic photon beams from 10 keV to 10 MeV based on the Chinese mathematical phantom, a whole-body mathematical phantom model. The model was developed based on the methods of the Oak Ridge National Laboratory mathematical phantom series and data from the Chinese Reference Man and the Reference Asian Man. This work is carried out to obtain the conversion coefficients based on this model, which represents the characteristics of the Chinese population, as the anatomical parameters of the Chinese are different from those of Caucasians. Monte Carlo simulation with MCNP code is carried out to calculate the organ dose conversion coefficients. Before the calculation, the effects from the physics model and tally type are investigated, considering both the calculation efficiency and precision. In the calculation irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic geometries. Conversion coefficients from this study are compared with those recommended in the Publication 74 of International Commission on Radiological Protection (ICRP74) since both the sets of data are calculated with mathematical phantoms. Overall, consistency between the two sets of data is observed and the difference for more than 60% of the data is below 10%. However, significant deviations are also found, mainly for the superficial organs (up to 65.9%) and bone surface (up to 66%). The big difference of the dose conversion coefficients for the superficial organs at high photon energy could be ascribed to kerma approximation for the data in ICRP74. Both anatomical variations between races and the calculation method contribute to the difference of the data for bone surface. (authors)

  14. External beam irradiation for retinoblastoma: patterns of failure and dose-response analysis

    International Nuclear Information System (INIS)

    Foote, R.L.; Garretson, B.R.; Schomberg, P.J.; Buskirk, S.J.; Robertson, D.M.; Earle, J.D.

    1989-01-01

    Eighteen children with retinoblastoma (25 eyes) were treated with external beam radiation at the Mayo Clinic between January 1977 and January 1987; 15 eyes were in groups I to III and 10 were in groups IV and V. The median number of tumors per eye was 3. Radiation therapy consisted of 4- or 6-MV photons. Doses varied from 39 to 51 Gy in 1.8- to 3.0-Gy fractions. Fourteen eyes were treated through lateral fields by anterior segment-sparing techniques, and 11 eyes were treated by an anterior approach with no attempt at anterior segment sparing. All patients survived (median follow-up, 31.5 months). Cataracts developed in five eyes at a median of 23 months, four in eyes treated with anterior segment-sparing techniques. Of the 15 group I to III eyes, 6 required additional treatment; 4 were salvaged with cryotherapy or photocoagulation and 2 were enucleated. Of the 10 group IV and V eyes, 8 required additional treatment; 4 were salvaged with cryotherapy or photocoagulation, 1 with persistent disease is being followed closely, and 3 were enucleated. Ten (71%) of the 14 eyes treated with anterior segment-sparing techniques required additional treatment. Four (36%) of the 11 eyes treated with an anterior approach required additional treatment. Ninety percent of the tumors 10 disc diameters or smaller (1 disc diameter = 1.6 mm) were controlled independently of dose and fractionation used when they were not in the low-dose area of the anterior retina of an eye treated with an anterior segment-sparing technique. We find that use of lateral, anterior segment-sparing techniques has a high risk of anterior retinal tumor development and cataract formation and should be abandoned in favor of techniques that treat the entire retina

  15. External beam irradiation for retinoblastoma: patterns of failure and dose-response analysis

    Energy Technology Data Exchange (ETDEWEB)

    Foote, R.L.; Garretson, B.R.; Schomberg, P.J.; Buskirk, S.J.; Robertson, D.M.; Earle, J.D.

    1989-03-01

    Eighteen children with retinoblastoma (25 eyes) were treated with external beam radiation at the Mayo Clinic between January 1977 and January 1987; 15 eyes were in groups I to III and 10 were in groups IV and V. The median number of tumors per eye was 3. Radiation therapy consisted of 4- or 6-MV photons. Doses varied from 39 to 51 Gy in 1.8- to 3.0-Gy fractions. Fourteen eyes were treated through lateral fields by anterior segment-sparing techniques, and 11 eyes were treated by an anterior approach with no attempt at anterior segment sparing. All patients survived (median follow-up, 31.5 months). Cataracts developed in five eyes at a median of 23 months, four in eyes treated with anterior segment-sparing techniques. Of the 15 group I to III eyes, 6 required additional treatment; 4 were salvaged with cryotherapy or photocoagulation and 2 were enucleated. Of the 10 group IV and V eyes, 8 required additional treatment; 4 were salvaged with cryotherapy or photocoagulation, 1 with persistent disease is being followed closely, and 3 were enucleated. Ten (71%) of the 14 eyes treated with anterior segment-sparing techniques required additional treatment. Four (36%) of the 11 eyes treated with an anterior approach required additional treatment. Ninety percent of the tumors 10 disc diameters or smaller (1 disc diameter = 1.6 mm) were controlled independently of dose and fractionation used when they were not in the low-dose area of the anterior retina of an eye treated with an anterior segment-sparing technique. We find that use of lateral, anterior segment-sparing techniques has a high risk of anterior retinal tumor development and cataract formation and should be abandoned in favor of techniques that treat the entire retina.

  16. Dose conversion coefficients based on the Chinese mathematical phantom and MCNP code for external photon irradiation.

    Science.gov (United States)

    Qiu, Rui; Li, Junli; Zhang, Zhan; Liu, Liye; Bi, Lei; Ren, Li

    2009-02-01

    A set of conversion coefficients from kerma free-in-air to the organ-absorbed dose are presented for external monoenergetic photon beams from 10 keV to 10 MeV based on the Chinese mathematical phantom, a whole-body mathematical phantom model. The model was developed based on the methods of the Oak Ridge National Laboratory mathematical phantom series and data from the Chinese Reference Man and the Reference Asian Man. This work is carried out to obtain the conversion coefficients based on this model, which represents the characteristics of the Chinese population, as the anatomical parameters of the Chinese are different from those of Caucasians. Monte Carlo simulation with MCNP code is carried out to calculate the organ dose conversion coefficients. Before the calculation, the effects from the physics model and tally type are investigated, considering both the calculation efficiency and precision. In the calculation irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic geometries. Conversion coefficients from this study are compared with those recommended in the Publication 74 of International Commission on Radiological Protection (ICRP74) since both the sets of data are calculated with mathematical phantoms. Overall, consistency between the two sets of data is observed and the difference for more than 60% of the data is below 10%. However, significant deviations are also found, mainly for the superficial organs (up to 65.9%) and bone surface (up to 66%). The big difference of the dose conversion coefficients for the superficial organs at high photon energy could be ascribed to kerma approximation for the data in ICRP74. Both anatomical variations between races and the calculation method contribute to the difference of the data for bone surface.

  17. Results of study of Sr-90 and Cs-137 content in organism and effective doses of internal and external irradiation of Ukrainian population residing in different regions

    International Nuclear Information System (INIS)

    Kalmykov, L.; Gur, E.

    1996-01-01

    The authors have studied effective doses of internal and external radiation for 1992-1994 in the residents of Chernigov and Kharkov Regions of Ukraine, i.e. those who live in the zone of strict radioecologic control and in relatively ''clean'' zones, respectively. In 95% of the investigated residents of Chernigov Region Cs-137 activity in the organism was lower than 1500 Bq, maximum amount being 11 kBq. Conditioned Cs-137 effective dose of internal radiation did not exceed 250 micro Sv per year, in 96% of the investigated subjects it was less than 30 micro Sv per year. Mean amount of this radionuclide in the organisms of both adults and children aged 3-6 years residing in Kharkov Region was 90 and 6 Bq respectively, dose being 2 and 0.4 micro Sv per year. Sr-90 amount in the bone tissue decreases with the age and for the residents of Chernigov region it was 7-23 Bq/kg of bone, for the adult residents of Kharkov region it was about 3 Bq/kg of bone. Mean effective dose of internal radiation due to Sr-90 incorporation for the residents of both Kharkov and Chernigov Regions was 0.7 and 1.9 micro Sv per year. Effective dose of external radiation for the residents of Kharkov Region has not changed since the Chernobyl accident. Total effective dose of external and internal radiation in various professional groups for the residents of Chernigov region increased by 80 micro Sv per year which makes up 14% of mean population dose in Ukraine. (author). 11 refs, 5 tabs

  18. Comparative study of reference points by dosimetric analyses for late complications after uniform external radiotherapy and high-dose-rate brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Chen, S.-W.; Liang, J.-A.; Yeh, L.-S.; Yang, S.-N.; Shiau, A.-C.; Lin, F.-J.

    2004-01-01

    Purpose: This study aimed to correlate and compare the predictive values of rectal and bladder reference doses of uniform external beam radiotherapy without shielding and high-dose-rate intracavitary brachytherapy (HDRICB) with late sequelae in patients with uterine cervical cancer. Methods and materials: Between September 1992 and December 1998, 154 patients who survived more than 12 months after treatment were studied. Initially, they were treated with 10-MV X-rays (44 to 45 Gy/22 to 25 fractions over 4 to 5 weeks) to the whole pelvis, after which HDRICB was performed using 192 Ir remote afterloading at 1-week intervals for 4 weeks. The standard prescribed dose for each HDRICB was 6.0 Gy to point A. Patient- and treatment-related-factors were evaluated for late rectal complications using logistic regression modeling. Results: The probability of rectal complications showed better correlation of dose-response with increasing total ICRU (International Committee on Radiotherapy Units and Measurements) rectal dose. Multivariate logistic regression demonstrated a high risk of late rectal sequelae in patients who developed rectal complications (p 0.0001;relative risk, 15.06;95% CI, 2.89∼43.7) and total ICRU rectal dose greater than 16 Gy (p = 0.02;relative risk, 2.07;95% CI, 1.13∼4.55). The high risk factors for bladder complications were seen in patients who developed rectal complications (p = 0.0001;relative risk, 15.2;95% CI, 2.81∼44.9) and total ICRU bladder dose greater than 24 Gy (p = 0.02;relative risk, 8.93;95% CI, 1.79∼33.1). Conclusion: This study demonstrated the predictive value of ICRU rectal and bladder reference dosing in HDRICB for patients receiving uniform external beam radiation therapy without central shielding. Patients who had a total ICRU rectal dose greater than 16 Gy, or a total ICRU bladder dose over 24 Gy, were at risk of late sequelae

  19. Enhancement of Transistor-to-Transistor Variability Due to Total Dose Effects in 65-nm MOSFETs

    CERN Document Server

    Gerardin, S; Cornale, D; Ding, L; Mattiazzo, S; Paccagnella, A; Faccio, F; Michelis, S

    2015-01-01

    We studied device-to-device variations as a function of total dose in MOSFETs, using specially designed test structures and procedures aimed at maximizing matching between transistors. Degradation in nMOSFETs is less severe than in pMOSFETs and does not show any clear increase in sample-to-sample variability due to the exposure. At doses smaller than 1 Mrad( SiO2) variability in pMOSFETs is also practically unaffected, whereas at very high doses-in excess of tens of Mrad( SiO2)-variability in the on-current is enhanced in a way not correlated to pre-rad variability. The phenomenon is likely due to the impact of random dopant fluctuations on total ionizing dose effects.

  20. Relative effect of radiation dose rate on hemopoietic and nonhemopoietic lethality of total-body irradiation

    International Nuclear Information System (INIS)

    Peters, L.J.; McNeill, J.; Karolis, C.; Thames, H.D. Jr.; Travis, E.L.

    1986-01-01

    Experiments were undertaken to determine the influence of dose rate on the toxicity of total-body irrdiation (TBI) with and without syngeneic bone-marrow rescue in mice. The results showed a much greater dose-rate dependence for death from nonhemopoietic toxicity than from bone-marrow ablation, with the ratio of LD 50 's increasing from 1.73 at 25 cGy/min to 2.80 at 1 cGy/min. At the higher dose rates, dose-limiting nonhemopoietic toxicity resulted from late organ injury, affecting the lungs, kidneys, and liver. At 1 cGy/min the major dose-limiting nonhemopoietic toxicity was acute gastrointestinal injury. The implications of these results in the context of TBI in preparation for bone-marrow transplantation are discussed. 15 refs., 4 figs

  1. Safety aspects of preoperative high-dose glucocorticoid in primary total knee replacement

    DEFF Research Database (Denmark)

    Jørgensen, C C; Pitter, F T; Kehlet, H

    2017-01-01

    Background: Preoperative single high-dose glucocorticoid may have early outcome benefits in total hip arthroplasty (THA) and knee arthroplasty (TKA), but long-term safety aspects have not been evaluated. Methods: From October 2013, the departments reporting to the prospective Lundbeck Foundation....... Conclusions: In this detailed prospective cohort study, preoperative high-dose glucocorticoid administration was not associated with LOS >4 days, readmissions or infectious complications in TKA patients without contraindications....

  2. Total dose effects on ATLAS-SCT front-end electronics

    CERN Document Server

    Ullán, M; Dubbs, T; Grillo, A A; Spencer, E; Seiden, A; Spieler, H; Gilchriese, M G D; Lozano, M

    2002-01-01

    Low dose rate effects (LDRE) in bipolar technologies complicate the hardness assurance testing for high energy physics applications. The damage produced in the ICs in the real experiment can be underestimated if fast irradiations are carried out, while experiments done at the real dose rate are usually unpractical due to the still high total doses involved. In this work the sensitivity to LDRE of two bipolar technologies proposed for the ATLAS-SCT experiment at CERN is evaluated, finding one of them free of those effects. (12 refs).

  3. Conventional external beam radiation therapy and high dose rate afterloading brachytherapy as a boost for patients older than 70 years

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Salvajoli, Joao Vitor; Fogaroli, Ricardo Cesar; Novaes, Paulo Eduardo R.S.; Maia, Maria Aparecida Conte; Ferrigno, Robson

    2005-01-01

    The treatment options for patients with non metastatic prostate cancer range from observation, radical prostatectomy, radiation therapy, hormonal therapy to various combination of some to all of them. Objective: we evaluated the impact on biochemical control of disease (bNED), acute and late intestinal (GI) and urological (GU) morbidity for a group of patients older than 70 years presenting initial or locally advanced prostate cancer treated with fractionated high dose rate brachytherapy (HDRB) as a boost to conventional external beam radiation therapy (RT) at the Department of Radiation Oncology from Hospital do Cancer A. C. Camargo, Sao Paulo, Brazil. Methods: a total of 56 patients older than 70 were treated from March, 1997 to June, 2002. All patients had prior to HDRB a course of RT to a median dose of 45 Gy. HDRB doses ranged from 16 Gy to 20 Gy, given in 4 fractions. Results: the median age of the patients was 74.4 years (range 70-83) and the median follow-up 33 months (range 24 to 60). The 5-year actuarial bNED rate was 77%. Acute GU and GI morbidity G1-2 were seen in 17.8% and 7.1% of patients, respectively. Late G1 or G2 GU morbidity was seen in 10.7% of the patients, while late G3 morbidity was observed in 7.1% of the patients, represented by urethral strictures. Conclusion: this group of patients had similar bNED rates when compared to literature, with acceptable morbidity rates. (author)

  4. The total dose effects on the 1/f noise of deep submicron CMOS transistors

    International Nuclear Information System (INIS)

    Hu Rongbin; Wang Yuxin; Lu Wu

    2014-01-01

    Using 0.18 μm CMOS transistors, the total dose effects on the 1/f noise of deep-submicron CMOS transistors are studied for the first time in mainland China. From the experimental results and the theoretic analysis, we realize that total dose radiation causes a lot of trapped positive charges in STI (shallow trench isolation) SiO 2 layers, which induces a current leakage passage, increasing the 1/f noise power of CMOS transistors. In addition, we design some radiation-hardness structures on the CMOS transistors and the experimental results show that, until the total dose achieves 750 krad, the 1/f noise power of the radiation-hardness CMOS transistors remains unchanged, which proves our conclusion. (semiconductor devices)

  5. Evaluation of surface and shallow depth dose reductions using a Superflab bolus during conventional and advanced external beam radiotherapy.

    Science.gov (United States)

    Yoon, Jihyung; Xie, Yibo; Zhang, Rui

    2018-03-01

    The purpose of this study was to evaluate a methodology to reduce scatter and leakage radiations to patients' surface and shallow depths during conventional and advanced external beam radiotherapy. Superflab boluses of different thicknesses were placed on top of a stack of solid water phantoms, and the bolus effect on surface and shallow depth doses for both open and intensity-modulated radiotherapy (IMRT) beams was evaluated using thermoluminescent dosimeters and ion chamber measurements. Contralateral breast dose reduction caused by the bolus was evaluated by delivering clinical postmastectomy radiotherapy (PMRT) plans to an anthropomorphic phantom. For the solid water phantom measurements, surface dose reduction caused by the Superflab bolus was achieved only in out-of-field area and on the incident side of the beam, and the dose reduction increased with bolus thickness. The dose reduction caused by the bolus was more significant at closer distances from the beam. Most of the dose reductions occurred in the first 2-cm depth and stopped at 4-cm depth. For clinical PMRT treatment plans, surface dose reductions using a 1-cm Superflab bolus were up to 31% and 62% for volumetric-modulated arc therapy and 4-field IMRT, respectively, but there was no dose reduction for Tomotherapy. A Superflab bolus can be used to reduce surface and shallow depth doses during external beam radiotherapy when it is placed out of the beam and on the incident side of the beam. Although we only validated this dose reduction strategy for PMRT treatments, it is applicable to any external beam radiotherapy and can potentially reduce patients' risk of developing radiation-induced side effects. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  6. Monte Carlo calculation of dose rate conversion factors for external exposure to photon emitters in soil

    CERN Document Server

    Clouvas, A; Antonopoulos-Domis, M; Silva, J

    2000-01-01

    The dose rate conversion factors D/sub CF/ (absorbed dose rate in air per unit activity per unit of soil mass, nGy h/sup -1/ per Bq kg/sup -1/) are calculated 1 m above ground for photon emitters of natural radionuclides uniformly distributed in the soil. Three Monte Carlo codes are used: 1) The MCNP code of Los Alamos; 2) The GEANT code of CERN; and 3) a Monte Carlo code developed in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki. The accuracy of the Monte Carlo results is tested by the comparison of the unscattered flux obtained by the three Monte Carlo codes with an independent straightforward calculation. All codes and particularly the MCNP calculate accurately the absorbed dose rate in air due to the unscattered radiation. For the total radiation (unscattered plus scattered) the D/sub CF/ values calculated from the three codes are in very good agreement between them. The comparison between these results and the results deduced previously by other authors indicates a good ag...

  7. Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film

    International Nuclear Information System (INIS)

    Gamble, Lisa M; Farrell, Thomas J; Jones, Glenn W; Hayward, Joseph E

    2003-01-01

    Total skin electron (TSE) radiotherapy is routinely used to treat cutaneous T-cell lymphomas and can be implemented using a modified Stanford technique. In our centre, the composite depth dose for this technique is achieved by a combination of two patient positions per day over a three-day cycle, and two gantry angles per patient position. Due to patient morphology, underdosed regions typically occur and have historically been measured using multiple thermoluminescent dosimeters (TLDs). We show that radiochromic film can be used as a two-dimensional relative dosimeter to measure the percent depth dose in TSE radiotherapy. Composite depth dose curves were measured in a cylindrical, polystyrene phantom and compared with TLD data. Both multiple films (1 film per day) and a single film were used in order to reproduce a realistic clinical scenario. First, three individual films were used to measure the depth dose, one per treatment day, and then compared with TLD data; this comparison showed a reasonable agreement. Secondly, a single film was used to measure the dose delivered over three daily treatments and then compared with TLD data; this comparison showed good agreement throughout the depth dose, which includes doses well below 1 Gy. It will be shown that one piece of radiochromic film is sufficient to measure the composite percent depth dose for a TSE beam, hence making radiochromic film a suitable candidate for monitoring underdosed patient regions

  8. An experimental study on total dose effects in SRAM-based FPGAs

    International Nuclear Information System (INIS)

    Yao Zhibin; He Baoping; Zhang Fengqi; Guo Hongxia; Luo Yinhong; Wang Yuanming; Zhang Keying

    2009-01-01

    In order to study testing methods and find sensitive parameters in total dose effects on SRAM-based FPGA, XC2S100 chips were irradiated by 60 Co γ-rays and tested with two test circuit designs. By analyzing the experimental results, the test flow of configuration RAM and bock RAM was given, and the most sensitive parameter was obtained. The results will be a solid foundation for establishing test specification and evaluation methods of total dose effects on SRAM-based FPGAs. (authors)

  9. Evaluation of personal dose equivalent 'HP(d)' in a external individual monitoring system for X and gamma radiation

    International Nuclear Information System (INIS)

    Santoro, C.; Antonio Filho, J.; Santos, M.A.P.

    2007-01-01

    The good of individual monitoring for external radiation is the assessment of occupational exposure from X and γ radiations in order to assure that the radiological conditions of the workplace are acceptable, safe and satisfactory. The evaluation of radiations doses for workers must not exceed dose limits specified for workers, according to national regulatory agencies. Nowadays, there are two external monitoring systems in use, both based on ICRU definitions. In the conventional system, the workers doses are evaluated in terms of Hx. The personal dosimeter is worn over chest surface and it is calibrated in function of air kerma. In the new system, the workers doses are evaluated in terms of HP(d) and the personal dosimeter is calibrated in function of phantom doses. The aim of this paper is to adapt an external dosimetry laboratory (based on photographic dosimetry) to evaluate the personal dosimeters in terms of HP(d). In this way, a simple methodology, based on linear programming, was utilized. In this adaptation, calibration curves were obtained for radiation qualities (W and N series) described by International Organization for Standardization (ISO 4037-1, 1995). These calibration curves offer a better accuracy on dose determinations and energy below 140 keV, improving the quality of service rendered the society. (author)

  10. Effect of Intrathecal Bupivacaine Dose on the Success of External Cephalic Version for Breech Presentation: A Prospective, Randomized, Blinded Clinical Trial.

    Science.gov (United States)

    Chalifoux, Laurie A; Bauchat, Jeanette R; Higgins, Nicole; Toledo, Paloma; Peralta, Feyce M; Farrer, Jason; Gerber, Susan E; McCarthy, Robert J; Sullivan, John T

    2017-10-01

    Breech presentation is a leading cause of cesarean delivery. The use of neuraxial anesthesia increases the success rate of external cephalic version procedures for breech presentation and reduces cesarean delivery rates for fetal malpresentation. Meta-analysis suggests that higher-dose neuraxial techniques increase external cephalic version success to a greater extent than lower-dose techniques, but no randomized study has evaluated the dose-response effect. We hypothesized that increasing the intrathecal bupivacaine dose would be associated with increased external cephalic version success. We conducted a randomized, double-blind trial to assess the effect of four intrathecal bupivacaine doses (2.5, 5.0, 7.5, 10.0 mg) combined with fentanyl 15 μg on the success rate of external cephalic version for breech presentation. Secondary outcomes included mode of delivery, indication for cesarean delivery, and length of stay. A total of 240 subjects were enrolled, and 239 received the intervention. External cephalic version was successful in 123 (51.5%) of 239 patients. Compared with bupivacaine 2.5 mg, the odds (99% CI) for a successful version were 1.0 (0.4 to 2.6), 1.0 (0.4 to 2.7), and 0.9 (0.4 to 2.4) for bupivacaine 5.0, 7.5, and 10.0 mg, respectively (P = 0.99). There were no differences in the cesarean delivery rate (P = 0.76) or indication for cesarean delivery (P = 0.82). Time to discharge was increased 60 min (16 to 116 min) with bupivacaine 7.5 mg or higher as compared with 2.5 mg (P = 0.004). A dose of intrathecal bupivacaine greater than 2.5 mg does not lead to an additional increase in external cephalic procedural success or a reduction in cesarean delivery.

  11. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A.

    1990-01-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy

  12. Generalized concept for the estimation of body dose for radiation workers exposed to external #betta#-rays

    International Nuclear Information System (INIS)

    Piesch, E.; Boehm, J.; Heinzelmann, M.

    1983-01-01

    In radiation protection monitoring the need exists for an estimation of body dose due to external #betta#-rays, for instance if the #betta#-dose rate at the working area is expected to be high according to the data of source activity or room contamination, the indicated dose values of a personal dosemeter exceed the operational limit for the organ or tissue depth of interest, or a person was exposed to a significant dose. On behalf of the Federal Ministry of the Interior, Federal Republic of Germany, a guideline is now under preparation which offers a standardized concept of the estimation of #betta#-doses in personnel monitoring. The calculation models discussed here will be used as a basis for any case of external #betta#-irradiation where, in connection with the German Radiation Protection Ordinance, the ICRP dose equivalent limits are reached or the dosemeter readings are not representative for an individual exposure. The generalized concept discussed in the paper relates to: the calculation of #betta#-dose on the basis of source activity or spectral particle fluence and takes into account the special cases of point sources, area sources and volume sources; the estimation of body dose on the basis of calculated data or measured results from area or personnel monitoring, taking into account the dose equivalent in different depths of tissue, in particular the dose equivalent to the skin, the lens of the eye and other organs; and finally the estimation of skin dose due to the contamination of the skin surface. Basic reference data are presented in order to estimate the dose equivalent of interest which varies significantly in the #betta#-radiation field as a function of the maximum #betta#-energy, distance to the source, size of the source, activity per area for surface contamination and activity per volume for air contamination

  13. Perspectives in absorbed dose metrology with regard to the technical evolutions of external beam radiotherapy

    International Nuclear Information System (INIS)

    Chauvenet, B.; Bordy, J.M.; Barthe, J.

    2009-01-01

    This paper presents several R and D axes in absorbed close metrology to meet the needs resulting from the technical evolutions of external beam radiotherapy. The facilities in operation in France have considerably evolved under the impulse of the plan Cancer launched in 2003: replacements and increase of the number of accelerators, substitution of accelerators for telecobalt almost completed and acquisition of innovative facilities for tomo-therapy and stereotaxy. The increasing versatility of facilities makes possible the rapid evolution of treatment modalities, allowing to better delimit irradiation to tumoral tissues and spare surrounding healthy tissues and organs at risk. This leads to a better treatment efficacy through dose escalation. National metrology laboratories must offer responses adapted to the new need, i.e. not restrict themselves to the establishment of references under conventional conditions defined at international level, contribute to the improvement of uncertainties at all levels of reference transfer to practitioners: primary measurements under conditions as close as possible to those of treatment, characterization of transfer and treatment control dosimeters., metrological validation of treatment planning tools... Those axes have been identified as priorities for the next years in ionizing radiation metrology at the European level and included in the European. Metrology Research Programme. A project dealing with some of those topics has been selected in the frame of the Eranet+ Call EMRP 2007 and is now starting. The LNE-LAM is strongly engaged in it. (authors)

  14. DOSE-Analyzer. A computer program with graphical user interface to analyze absorbed dose inside a body of mouse and human upon external neutron exposure

    International Nuclear Information System (INIS)

    Satoh, Daiki; Takahashi, Fumiaki; Shigemori, Yuji; Sakamoto, Kensaku

    2010-06-01

    DOSE-Analyzer is a computer program to retrieve the dose information from a database and generate a graph through a graphical user interface (GUI). The database is constructed for absorbed dose, fluence, and energy distribution inside a body of mouse and human exposed upon external neutrons, which is calculated by our developed Monte-Carlo simulation method using voxel-based phantom and particle transport code PHITS. The input configurations of irradiation geometry, subject, and energy are set by GUI. The results are tabulated at particle types, i.e. electron, proton, deuteron, triton, and alpha particle, and target organs on a data sheet of Microsoft Office Excel TM . Simple analysis to compare the output values for two subjects is also performed on DOSE-Analyzer. This report is a user manual of DOSE-Analyzer. (author)

  15. ANALYSIS OF DATA ON DOSES OF EXTERNAL TERRIGENOUS IRRADIATION OF THE RUSSIAN FEDERATION POPULATION IN MUNICIPAL CONDITIONS

    Directory of Open Access Journals (Sweden)

    I. P. Stamat

    2015-01-01

    Full Text Available By this time in the Russian Federation there is collected a huge file of data describing the influence of all natural sources of ionizing radiation on population in municipal conditions. These data are collected and generalized in radiation hygiene passports of the Russian Federation for the last 16 years and in the reporting forms of federal statistical supervision No 4-DOZ “Data on doses of population irradiation due to the natural and manchanged radiation background” for a period of 14 years. These data are received by direct measurements of gamma radiation dose rate in the premises and in the open air on the territory of settlements. Measurements were made with the most different dosimeters; their technical and metrological parameters differ considerably. In this regard of certain interest is evaluation of this data reliability degree; that will help to find out the reasons of higher levels of the Russian Federation population external irradiation in comparison with average global dose values.In this article an attempt was made to evaluate reliability degree of data on the population external irradiation doses using the radiation hygiene passports of territories and reporting forms No 4-DOZ for the whole period of supervision. For this there was used the known dependence between the gamma radiation dose rate and natural radionuclides effective specific activity (AEFF in inhabitancy objects. For this purpose there were used the data on average AEFF values of building raw materials and of local manufacture materials, which are presented in radiation hygiene passports of territories. Definition of design value of gamma radiation dose rate in the buildings and in the open air according to AEFF measurement data in building raw materials and in local manufacture materials actually enables to get an independent evaluation of the population external irradiation doses. Comparison of two evaluations of the population external irradiation levels

  16. A simple and fast physics-based analytical method to calculate therapeutic and stray doses from external beam, megavoltage x-ray therapy.

    Science.gov (United States)

    Jagetic, Lydia J; Newhauser, Wayne D

    2015-06-21

    State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 min. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models.

  17. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy.

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-21

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR 20,10 , using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR 20,10 . With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR 20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR 20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR 20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR 20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR 20,10 value.

  18. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-01

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR20,10, using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR20,10. With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR20,10 value.

  19. Enchanced total dose damage in junction field effect transistors and related linear integrated circuits

    International Nuclear Information System (INIS)

    Flament, O.; Autran, J.L.; Roche, P.; Leray, J.L.; Musseau, O.

    1996-01-01

    Enhanced total dose damage of Junction Field-effect Transistors (JFETs) due to low dose rate and/or elevated temperature has been investigated for elementary p-channel structures fabricated on bulk and SOI substrates as well as for related linear integrated circuits. All these devices were fabricated with conventional junction isolation (field oxide). Large increases in damage have been revealed by performing high temperature and/or low dose rate irradiations. These results are consistent with previous studies concerning bipolar field oxides under low-field conditions. They suggest that the transport of radiation-induced holes through the oxide is the underlying mechanism. Such an enhanced degradation must be taken into account for low dose rate effects on linear integrated circuits

  20. Analysis of external dose to the people living at the territory contaminated due to the Chernobyl accident

    International Nuclear Information System (INIS)

    Bondarenko, O.; Medvedev, S.; Kireev, S.; Proskura, M.

    2004-01-01

    Within the framework of international collaboration took place in 1996-1999 State Specialised Enterprise 'RADEC' (now it is SSSIE E cocentre ) and Japan Atomic Energy Research Institute (JAERI) measurements was performed of equivalent dose of people living at the Chernobyl exclusion zone. In 1997-1998, 273 people were chosen from 23 villages of the Chernobyl exclusion zone and each of them acquired three dosimeters Toshiba GD-400. The first dosimeter was assigned for the measurement of external individual dose, indoor dose inside dwellings and outdoor dose in yards. Exposition time varied from one to three months. Linear approximation of the obtained data gave possibility to find dependence of individual, home and outdoor doses on the surface density of 137 Cs contamination of village territory. This coefficient for the individual dose was found about 0.7μSv.year -1 /(kBq.m -2 ) that is agreed with literature data. Also a constant contribution of the natural external exposure to the individual dose was found about 0.9 mSv.year -1 . Availability of results for three types of doses (i.e. individual, home and outdoor) let calculate two other useful coefficients, namely, the shielding factor and the behaviour factor. These factors were found equal 4.8 and 0.39, correspondingly. Studying of variation of the experimental data around the approximated values let assess statistics uncertainties of the measurements. Having applied the 99% percentile to the distribution of the ratio of the measured dose to the approximation the safety factor was found about 3. Also the external radiation long-term series provided by the automated system of monitoring of radiation situation (ASMRS) at the Chernobyl exclusion zone were analysed. That analysis revealed that the dose rate is leveled off during the last 6 years (taking into account radioactive decay). However, our finding is not compliant to other authors according to whom the rate of diminishing of the environmental external

  1. Total dose hardness of a commercial SiGe BiCMOS technology

    International Nuclear Information System (INIS)

    Van Vonno, N.; Lucas, R.; Thornberry, D.

    1999-01-01

    Over the past decade SiGe HBT technology has progress from the laboratory to actual commercial applications. When integrated into a BiMOS process, this technology has applications in low-cost space systems. In this paper, we report results of total dose testing of a SiGe/CMOS process accessible through a commercial foundry. (authors)

  2. Worst-Case Bias During Total Dose Irradiation of SOI Transistors

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Colladant, T.; Paillet, P.; Leray, J.-L; Musseau, O.; Schwank, James R.; Shaneyfelt, Marty R.; Pelloie, J.L.; Du Port de Poncharra, J.

    2000-01-01

    The worst case bias during total dose irradiation of partially depleted SOI transistors (from SNL and from CEA/LETI) is correlated to the device architecture. Experiments and simulations are used to analyze SOI back transistor threshold voltage shift and charge trapping in the buried oxide

  3. Recent Total Ionizing Dose Results and Displacement Damage Results for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    Cochran, Donna J.; Buchner, Stephen P.; Irwin, Tim L.; LaBel, Kenneth A.; Marshall, Cheryl J.; Reed, Robert A.; Sanders, Anthony B.; Hawkins, Donald K.; Flanigan, Ryan J.; Cox, Stephen R.

    2005-01-01

    We present data on the vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage. Devices tested include optoelectronics, digital, analog, linear bipolar devices, hybrid devices, Analog-to- Digital Converters (ADCs), and Digital-to-Analog Converters (DACs), among others. T

  4. Inclusion of Radiation Environment Variability in Total Dose Hardness Assurance Methodology

    Science.gov (United States)

    Xapsos, M. A.; Stauffer, C.; Phan, A.; McClure, S. S.; Ladbury, R. L.; Pellish, J. A.; Campola, M. J.; LaBel, K. A.

    2016-01-01

    Variability of the space radiation environment is investigated with regard to parts categorization for total dose hardness assurance methods. It is shown that it can have a significant impact. A modified approach is developed that uses current environment models more consistently and replaces the radiation design margin concept with one of failure probability during a mission.

  5. The influence of x-ray energy on lung dose uniformity in total-body irradiation

    International Nuclear Information System (INIS)

    Ekstrand, Kenneth; Greven, Kathryn; Wu Qingrong

    1997-01-01

    Purpose: In this study we examine the influence of x-ray energy on the uniformity of the dose within the lung in total-body irradiation treatments in which partial transmission blocks are used to control the lung dose. Methods and Materials: A solid water phantom with a cork insert to simulate a lung was irradiated by x-rays with energies of either 6, 10, or 18 MV. The source to phantom distance was 3.9 meters. The cork insert was either 10 cm wide or 6 cm wide. Partial transmission blocks with transmission factors of 50% were placed anterior to the cork insert. The blocks were either 8 or 4 cm in width. Kodak XV-2 film was placed in the midline of the phantom to record the dose. Midplane dose profiles were measured with a densitometer. Results: For the 10 cm wide cork insert the uniformity of the dose over 80% of the block width varied from 6.6% for the 6 MV x-rays to 12.2% for the 18 MV x-rays. For the 6 cm wide cork insert the uniformity was comparable for all three x-ray energies, but for 18 MV the central dose increased by 9.4% compared to the 10 cm wide insert. Conclusion: Many factors must be considered in optimizing the dose for total-body irradiation. This study suggests that for AP/PA techniques lung dose uniformity is superior with 6 MV irradiation. The blanket recommendation that the highest x-ray energy be used in TBI is not valid for all situations

  6. SU-E-T-357: Electronic Compensation Technique to Deliver Total Body Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [State University of New York at Buffalo, Buffalo, NY (United States); Wang, I; Podgorsak, M [State University of New York at Buffalo, Buffalo, NY (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient’s immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has conventionally been used to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Methods: Treatment plans utilizing electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two, specifically weighted, pair of opposed fields. One pair of open, large fields (collimator=45°), to encompass the patient’s entire anatomy, and one pair of smaller fields (collimator=0°) focused only on the thicker midsection of the patient. The optimal fluence for each one of the smaller fields was calculated at a patient specific penetration depth. Irregular surface compensators provide a more uniform dose distribution within the smaller opposed fields. Results: Dose-volume histograms (DVH) were calculated for the evaluating the electronic compensation technique. In one case, the maximum body doses calculated from the DVH were reduced from the non-compensated 195.8% to 165.3% in the electronically compensated plans, indicating a more uniform dose with the region of electronic compensation. The mean body doses calculated from the DVH were also reduced from the non-compensated 120.6% to 112.7% in the electronically compensated plans, indicating a more accurate delivery of the prescription dose. All calculated monitor units were well within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not substantially increase the beam on time while it can significantly reduce the compensator

  7. External radiation dose and cancer mortality among French nuclear workers. Considering potential confounding by internal radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, L.; Laurent, O.; Samson, E.; Caer-Lorho, S.; Laurier, D.; Leuraud, K. [Institute for Radiological Protection and Nuclear Safety, Fontenay aux Roses (France). Ionizing Radiation Epidemiology Lab.; Laroche, P. [AREVA, Paris (France); Le Guen, B. [EDF, Saint Denis (France)

    2016-11-15

    French nuclear workers have detailed records of their occupational exposure to external radiation that have been used to examine associations with subsequent cancer mortality. However, some workers were also exposed to internal contamination by radionuclides. This study aims to assess the potential for bias due to confounding by internal contamination of estimates of associations between external radiation exposure and cancer mortality. A cohort of 59,004 workers employed for at least 1 year between 1950 and 1994 by CEA (Commissariat a l'Energie Atomique), AREVA NC, or EDF (Electricite de France) and badge-monitored for external radiation exposure were followed through 2004 to assess vital status and cause of death. A flag based on a workstation-exposure matrix defined four levels of potential for internal contamination. Standardized mortality ratios were assessed for each level of the internal contamination indicator. Poisson regression was used to quantify associations between external radiation exposure and cancer mortality, adjusting for potential internal contamination. For solid cancer, the mortality deficit tended to decrease as the levels of potential for internal contamination increased. For solid cancer and leukemia excluding chronic lymphocytic leukemia, adjusting the dose-response analysis on the internal contamination indicator did not markedly change the excess relative risk per Sievert of external radiation dose. This study suggests that in this cohort, neglecting information on internal dosimetry while studying the association between external dose and cancer mortality does not generate a substantial bias. To investigate more specifically the health effects of internal contamination, an effort is underway to estimate organ doses due to internal contamination.

  8. External radiation dose and cancer mortality among French nuclear workers: considering potential confounding by internal radiation exposure.

    Science.gov (United States)

    Fournier, L; Laurent, O; Samson, E; Caër-Lorho, S; Laroche, P; Le Guen, B; Laurier, D; Leuraud, K

    2016-11-01

    French nuclear workers have detailed records of their occupational exposure to external radiation that have been used to examine associations with subsequent cancer mortality. However, some workers were also exposed to internal contamination by radionuclides. This study aims to assess the potential for bias due to confounding by internal contamination of estimates of associations between external radiation exposure and cancer mortality. A cohort of 59,004 workers employed for at least 1 year between 1950 and 1994 by CEA (Commissariat à l'Energie Atomique), AREVA NC, or EDF (Electricité de France) and badge-monitored for external radiation exposure were followed through 2004 to assess vital status and cause of death. A flag based on a workstation-exposure matrix defined four levels of potential for internal contamination. Standardized mortality ratios were assessed for each level of the internal contamination indicator. Poisson regression was used to quantify associations between external radiation exposure and cancer mortality, adjusting for potential internal contamination. For solid cancer, the mortality deficit tended to decrease as the levels of potential for internal contamination increased. For solid cancer and leukemia excluding chronic lymphocytic leukemia, adjusting the dose-response analysis on the internal contamination indicator did not markedly change the excess relative risk per Sievert of external radiation dose. This study suggests that in this cohort, neglecting information on internal dosimetry while studying the association between external dose and cancer mortality does not generate a substantial bias. To investigate more specifically the health effects of internal contamination, an effort is underway to estimate organ doses due to internal contamination.

  9. SU-E-J-181: Effect of Prostate Motion On Combined Brachytherapy and External Beam Dose Based On Daily Motion of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Narayana, V; McLaughlin, P [Providence Cancer Center, Southfield, MI (United States); University of Michigan, Ann Arbor, MI (United States); Ealbaj, J [University of Michigan, Ann Arbor, MI (United States)

    2015-06-15

    Purpose: In this study, the adequacy of target expansions on the combined external beam and implant dose was examined based on the measured daily motion of the prostate. Methods: Thirty patients received an I–125 prostate implant prescribed to dose of 90Gy. This was followed by external beam to deliver a dose of 90Gyeq (external beam equivalent) to the prostate over 25 to 30 fractions. An ideal IMRT plan was developed by optimizing the external beam dose based on the delivered implant dose. The implant dose was converted to an equivalent external beam dose using the linear quadratic model. Patients were set up on the treatment table by daily orthogonal imaging and aligning the marker seeds in the prostate. Orthogonal images were obtained at the end of treatment to assess prostate intrafraction motion. Based on the observed motion of the markers between the initial and final images, 5 individual plans showing the actual dose delivered to the patient were calculated. A final true dose distribution was established based on summing the implant dose and the 5 external beam plans. Dose to the prostate, seminal vesicles, lymphnodes and normal tissues, rectal wall, urethra and lower sphincter were calculated and compared to ideal. On 18 patients who were sexually active, dose to the corpus cavernosum and internal pudendal artery was also calculated. Results: The average prostate motion in 3 orthogonal directions was less than 1 mm with a standard deviation of less than +2 mm. Dose and volume parameters showed that there was no decrease in dose to the targets and a marginal decrease in dose to in normal tissues. Conclusion: Dose delivered by seed implant moves with the prostate, decreasing the impact of intrafractions dose movement on actual dose delivered. Combined brachytherapy and external beam dose delivered to the prostate was not sensitive to prostate motion.

  10. Implication of new CEC recommendations for individual monitoring for external radiation doses to the skin and the extremities

    International Nuclear Information System (INIS)

    Christensen, P.; Julius, H.W.; Marshall, T.O.

    1991-01-01

    A drafting group consisting of the above authors has assisted the CEC in revising the CEC document Technical Recommendations for Monitoring the Exposure to Individuals to External Radiation, EUR 5287, published in 1975. The paper highlights sections of the revised version relating particularly to irradiation of the skin and the extremities and focusses on problems connected to exposure to weakly penetrating radiations. Concepts of individual monitoring for external radiation exposures to the skin of the whole body and to the extremities are discussed and guidance is given as regards dose quantities and dosemeter calibration procedures. A method of quantifying the overall accuracy of the dose measurements as a result of the various uncertainty components connected with the dosimetry system is suggested and requirements on the accuracy of the dose measurements complying with the ICRP requirements on overall accuracy for individual monitoring are specified. Moreover, implications of the accuracy requirements for the design and type testing of the dosemeter are discussed. (author)

  11. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    CERN Document Server

    Endo, A; Zankl, M; Bolch, W E; Eckerman, K F; Hertel, N E; Hunt, J G; Pelliccioni, M; Schlattl, H; Menzel, H-G

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors.

  12. Use of a concise prescription for specifying absolute dose distribution in external beam radiation therapy

    International Nuclear Information System (INIS)

    Viggers, D.A.; Shalev, S.

    1989-01-01

    Radiation therapy dose distributions are usually calculated relative to some normalization point to which a prescribed dose in grays is to be delivered. Often the radiation therapist requests that the prescribed dose be delivered to some other point(s), such as the 90% isodose. Therefore the prescribed dose is not well defined. Furthermore, this procedure leaves the shape of the dose distribution unspecified. The authors have used a dose prescription specifying the volumes of target and nontarget tissue that must lie within dose limits stated in grays. These dose-volume limits determine the magnitude and shape of the dose distribution. The prescription is well defined while allowing the absolute dose at a chosen point to be adjusted so that the dose distribution satisfies the prescription

  13. Electron dose-rate conversion factors for external exposure of the skin from uniformly deposited activity on the body surface

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1987-01-01

    Dose-rate conversion factors have been calculated for external exposure of the skin from electrons emitted by sources that are deposited uniformly on the body surface. The dose-rate factors are obtained from electron scaled point kernels developed by Berger. The dose-rate factors are calculated at depths of 4, 8, and 40 mg cm-2 below the body surface as recommended by Whitton, and at a depth of 7 mg cm-2 as recommended in ICRP Publication 26 (ICRP77). The dependence of the dose-rate factors at selected depths on the energy of the emitted electrons is displayed. The dose-rate factors for selected radionuclides of potential importance in radiological assessments are tabulated

  14. A method, using ICRP 26 weighting factors, to determine effective dose equivalent due to nonuniform external exposures

    International Nuclear Information System (INIS)

    Dyer, S.G.

    1993-01-01

    Westinghouse Savannah River Company (WSRC) has recently implemented a methodology and supporting procedures to calculate effective dose equivalent for external exposures. The calculations are based on ICRP 26 methodology and are used to evaluate exposures when multibadging is used. The methodology is based upon the concept of open-quotes whole bodyclose quotes compartmentalization (i.e., the whole body is separated into seven specific regions of radiological concern and weighted accordingly). The highest dose measured in each compartment is used to determine the weighted dose to that compartment. Benefits of determining effective dose equivalent are compliance with DOE Orders, more accurate dose assessments, and the opportunity for improved worker protection through new ALARA opportunities

  15. Evaluation of the radiation doses to uranium mine employees exposed to external gamma radiation

    International Nuclear Information System (INIS)

    Young, J.G.; Wilson, O.J.

    1983-02-01

    Factors to convert a personal monitor badge reading to an effective dose equivalent are given for several exposure geometries encountered in uranium mines. Factors are also given that relate a free air absorbed dose measurement to an effective dose equivalent. In addition, factors are reported which can be used to estimate the dose equivalent to the testes, ovaries and active bone marrow

  16. Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure.

    Science.gov (United States)

    Camarata, Andrew S; Switchenko, Jeffrey M; Demidenko, Eugene; Flood, Ann B; Swartz, Harold M; Ali, Arif N

    2016-04-01

    Current radiation disaster manuals list the time-to-emesis (TE) as the key triage indicator of radiation dose. The data used to support TE recommendations were derived primarily from nearly instantaneous, high dose-rate exposures as part of variable condition accident databases. To date, there has not been a systematic differentiation between triage dose estimates associated with high and low dose rate (LDR) exposures, even though it is likely that after a nuclear detonation or radiologic disaster, many surviving casualties would have received a significant portion of their total exposure from fallout (LDR exposure) rather than from the initial nuclear detonation or criticality event (high dose rate exposure). This commentary discusses the issues surrounding the use of emesis as a screening diagnostic for radiation dose after LDR exposure. As part of this discussion, previously published clinical data on emesis after LDR total body irradiation (TBI) is statistically re-analyzed as an illustration of the complexity of the issue and confounding factors. This previously published data includes 107 patients who underwent TBI up to 10.5 Gy in a single fraction delivered over several hours at 0.02 to 0.04 Gy min. Estimates based on these data for the sensitivity of emesis as a screening diagnostic for the low dose rate radiation exposure range from 57.1% to 76.6%, and the estimates for specificity range from 87.5% to 99.4%. Though the original data contain multiple confounding factors, the evidence regarding sensitivity suggests that emesis appears to be quite poor as a medical screening diagnostic for LDR exposures.

  17. Time- and dose-dependent effects of total-body ionizing radiation on muscle stem cells

    Science.gov (United States)

    Masuda, Shinya; Hisamatsu, Tsubasa; Seko, Daiki; Urata, Yoshishige; Goto, Shinji; Li, Tao-Sheng; Ono, Yusuke

    2015-01-01

    Exposure to high levels of genotoxic stress, such as high-dose ionizing radiation, increases both cancer and noncancer risks. However, it remains debatable whether low-dose ionizing radiation reduces cellular function, or rather induces hormetic health benefits. Here, we investigated the effects of total-body γ-ray radiation on muscle stem cells, called satellite cells. Adult C57BL/6 mice were exposed to γ-radiation at low- to high-dose rates (low, 2 or 10 mGy/day; moderate, 50 mGy/day; high, 250 mGy/day) for 30 days. No hormetic responses in proliferation, differentiation, or self-renewal of satellite cells were observed in low-dose radiation-exposed mice at the acute phase. However, at the chronic phase, population expansion of satellite cell-derived progeny was slightly decreased in mice exposed to low-dose radiation. Taken together, low-dose ionizing irradiation may suppress satellite cell function, rather than induce hormetic health benefits, in skeletal muscle in adult mice. PMID:25869487

  18. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiotherapy and Radiooncology, Muenster (Germany); Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette [University Hospital of Muenster, Department of Phoniatrics and Pediatric Audiology, Muenster (Germany)

    2017-11-15

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D{sub mean}), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D{sub mean} was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m{sup 2}, with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D{sub mean} exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [German] Analyse von Inzidenz und Schweregrad einer sensorineuralen Schwerhoerigkeit (''sensorineural hearing loss'', SNHL) infolge der Wirkung unterschiedlicher Bestrahlungstechniken, Fraktionierungen, mittlerer

  19. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  20. Total dose hardening of buried insulator in implanted silicon-on-insulator structures

    International Nuclear Information System (INIS)

    Mao, B.Y.; Chen, C.E.; Pollack, G.; Hughes, H.L.; Davis, G.E.

    1987-01-01

    Total dose characteristics of the buried insulator in implanted silicon-on-insulator (SOI) substrates have been studied using MOS transistors. The threshold voltage shift of the parasitic back channel transistor, which is controlled by charge trapping in the buried insulator, is reduced by lowering the oxygen dose as well as by an additional nitrogen implant, without degrading the front channel transistor characteristics. The improvements in the radiation characteristics of the buried insulator are attributed to the decrease in the buried oxide thickness or to the presence of the interfacial oxynitride layer formed by the oxygen and nitrogen implants

  1. Determination of the radiation dose to the body due to external radiation

    International Nuclear Information System (INIS)

    Drexler, G.; Eckerl, H.

    1985-01-01

    Section 63 of the Radiation Protection Ordinance defines the basic requirement, determination of radiation dose to the body. The determination of dose equivalents for the body is the basic step in practical monitoring of dose equivalents or dose limits with regard to individuals or population groups, both for constant or varying conditions of exposure. The main field of monitoring activities is the protection of persons occupationally exposed to ionizing radiation. Conversion factors between body doses and radiation quantities are explained. (DG) [de

  2. Estimation of individual doses from external exposures and dose-group classification of cohort members in high background radiation area in Yangjiang, China

    International Nuclear Information System (INIS)

    Yuan Yongling; Shen Hong; Sun Quanfu; Wei Luxin

    1999-01-01

    Objective: In order to estimate annual effective doses from external exposures in the high background radiation area (HBRA) and in the control area (CA) , the authors measured absorbed dose rates in air from terrestrial gamma radiation with different dosimeters. A dose group classification was an important step for analyzing the dose effects relationship among the cohort members in the investigated areas. The authors used the hamlet specific average annual effective doses of all the 526 hamlets in the investigated areas. A classification of four dose groups was made for the cohort members (high, moderate, low and control) . Methods: For the purpose of studying the dose effect relationships among the cohort members in HBRA and CA, it would be ideal that each subject has his own record of individual accumulated doses received before the evaluation. However, rt is difficult to realize it in practice (each of 106517 persons should wear TLD for a long time) . Thus the authors planned two sets of measurements. Firstly, to measure the environmental dose rates (outdoor, indoor, over the bed) in every hamlet of the investigated area (526 hamlets) , considering the occupancy factors for males and females of different age groups to convert to the annual effective dose from the data of dose rates. Secondly, to measure the individual cumulative dose with TLD for part of the subjects in the investigated areas. Results: Based on the two sets of measurements, the estimates of average annual effective doses in HBRA were 211.86 and 206.75 x 10 -5 Sv/a, respectively, 68.60 and 67.11 x 10 -5 Sv/a, respectively(gamma radiation only) . The intercomparison between these two sets of measurement showed that they were in good correlation. Thus the authors are able to yield the equations of linear regression: Y = 0.9937 + 6.0444, r = 0.9949. Conclusions: The authors took the value obtained from direct measurement as 'standard' , and 15 % for uncertainty of measurement. Since the estimates of

  3. Organ dose conversion coefficients based on a voxel mouse model and MCNP code for external photon irradiation.

    Science.gov (United States)

    Zhang, Xiaomin; Xie, Xiangdong; Cheng, Jie; Ning, Jing; Yuan, Yong; Pan, Jie; Yang, Guoshan

    2012-01-01

    A set of conversion coefficients from kerma free-in-air to the organ absorbed dose for external photon beams from 10 keV to 10 MeV are presented based on a newly developed voxel mouse model, for the purpose of radiation effect evaluation. The voxel mouse model was developed from colour images of successive cryosections of a normal nude male mouse, in which 14 organs or tissues were segmented manually and filled with different colours, while each colour was tagged by a specific ID number for implementation of mouse model in Monte Carlo N-particle code (MCNP). Monte Carlo simulation with MCNP was carried out to obtain organ dose conversion coefficients for 22 external monoenergetic photon beams between 10 keV and 10 MeV under five different irradiation geometries conditions (left lateral, right lateral, dorsal-ventral, ventral-dorsal, and isotropic). Organ dose conversion coefficients were presented in tables and compared with the published data based on a rat model to investigate the effect of body size and weight on the organ dose. The calculated and comparison results show that the organ dose conversion coefficients varying the photon energy exhibits similar trend for most organs except for the bone and skin, and the organ dose is sensitive to body size and weight at a photon energy approximately <0.1 MeV.

  4. Low-dose total skin electron beam therapy for cutaneous lymphoma. Minimal risk of acute toxicities

    Energy Technology Data Exchange (ETDEWEB)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiation Oncology, Muenster (Germany)

    2017-12-15

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T-cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P < 0.001). A lower grade 3 AE rate was also observed in patients who had received the low-dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses. (orig.) [German] Eine niedrigdosierte Ganzhautelektronenbestrahlung (TSEBT) wird vermehrt zur effektiven palliativen Behandlung von Patienten mit primaer kutanen T-Zell-Lymphomen (pCTCL) eingesetzt. In dieser Studie vergleichen wir die Toxizitaetsprofile verschiedener Dosiskonzepte. Untersucht wurden 60 zwischen 2000 und 2016 am Universitaetsklinikum Muenster mittels TSEBT

  5. Dose distribution in the area of the operative cicatrice and the problem of local reccurences during postoperative external beam gamma therapy of breast cancer

    International Nuclear Information System (INIS)

    Todorov, Y.; Ivanova, K.; Penchev, V.

    1982-01-01

    Five-year experience is recorded with treatment of 503 patients with breast cancer, who received postoperative external beam gamma therapy, and the developement of local reccurences. Results are reported of dosimetric studies in the irradiated area, especially the thoracic wall, where total focal doses of 50 had been realized. The clinical results of treatment are discussed on this basis. Comparison is made with data available in the literature on the incidence, localization and time of development of local reccurences and the methods of treatment of the basic disease. The need of postoperative radiation treatment, particularly in the later stages of the disease, is pointed out. (authors)

  6. Implication of new CEC recommendations for individual monitoring for external radiation doses to the skin and the extremities

    DEFF Research Database (Denmark)

    Christensen, P.; Julius, H.W.; Marshall, T.O.

    1991-01-01

    A drafting group consisting of the above authors has assisted the CEC in revising the CEC document Technical Recommendations for Monitoring the Exposure to Individuals to External Radiation, EUR 5287, published in 1975. The paper highlights sections of the revised version relating particularly...... to irradiation of the skin and the extremities and focusses on problems connected to exposure to weakly penetrating radiations. Concepts of individual monitoring for external radiation exposures to the skin of the whole body and to the extremities are discussed and guidance is given as regards dose quantities...

  7. Dose-escalated total body irradiation and autologous stem cell transplantation for refractory hematologic malignancy

    International Nuclear Information System (INIS)

    McAfee, Steven L.; Powell, Simon N.; Colby, Christine; Spitzer, Thomas R.

    2002-01-01

    Purpose: To evaluate the feasibility of dose escalation of total body irradiation (TBI) above the previously reported maximally tolerated dose, we have undertaken a Phase I-II trial of dose-escalated TBI with autologous peripheral blood stem cell transplantation (PBSCT) for chemotherapy-refractory lymphoma. Methods and Materials: Nine lymphoma patients with primary refractory disease (PRD) or in resistant relapse (RR) received dose-escalated TBI and PBSCT. The three dose levels of fractionated TBI (200 cGy twice daily) were 1,600 cGy, 1,800 cGy, and 2,000 cGy. Lung blocks were used to reduce the TBI transmission dose by 50%, and the chest wall dose was supplemented to the prescribed dose using electrons. Shielding of the kidneys was performed to keep the maximal renal dose at 1,600 cGy. Three patients, two with non-Hodgkin's lymphoma (NHL) in RR and one with PRD Hodgkin's disease, received 1,600 cGy + PBSCT, three patients (two NHL in RR, one PRD) received 1,800 cGy + PBSCT, and three patients with NHL (two in RR, one PRD) received 2,000 cGy + PBSCT. Results: Toxicities associated with this high-dose TBI regimen included reversible hepatic veno-occlusive disease in 1 patient, Grade 2 mucositis requiring narcotic analgesics in 8 patients, and neurologic toxicities consisting of a symmetrical sensory neuropathy (n=4) and Lhermitte's syndrome (n=1). Interstitial pneumonitis developed in 1 patient who received 1,800 cGy after receiving recombinant α-interferon (with exacerbation after rechallenge with interferon). Six (66%) patients achieved a response. Four (44%) patients achieved complete responses, three of which were of a duration greater than 1 year, and 2 (22%) patients achieved a partial response. One patient remains disease-free more than 5 years posttransplant. Corticosteroid-induced gastritis and postoperative infection resulted in the death of 1 patient in complete response, 429 days posttransplant. Conclusion: TBI in a dose range 1,600-2,000 cGy as

  8. Measurement with total scatter calibrate factor at different depths in the calculation of prescription dose

    International Nuclear Information System (INIS)

    Li Lijun; Zhu Haijun; Zhang Xinzhong; Li Feizhou; Song Hongyu

    2004-01-01

    Objective: To evaluate the method of measurement of total scatter calibrate factor (Sc, p). Methods: To measure the Sc, p at different depths on central axis of 6MV, 15MV photon beams through different ways. Results: It was found that the measured data of Sc, p changed with the different depths to a range of 1% - 7%. Using the direct method, the Sc, p measured depth should be the same as the depth in dose normalization point of the prescription dose. If the Sc, p (fsz, d) was measured at the other depths, it could be obtained indirectly by the calculation formula. Conclusions: The Sc, p in the prescription dose can be obtained either by the direct measure method or the indirect calculation formula. But emphasis should be laid on the proper measure depth. (authors)

  9. Statistical analysis of dose heterogeneity in circulating blood: Implications for sequential methods of total body irradiation

    International Nuclear Information System (INIS)

    Molloy, Janelle A.

    2010-01-01

    Purpose: Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these ''sequential'' techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Methods: Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. Results: The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than ±10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times

  10. Statistical analysis of dose heterogeneity in circulating blood: implications for sequential methods of total body irradiation.

    Science.gov (United States)

    Molloy, Janelle A

    2010-11-01

    Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these "sequential" techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than +/- 10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times. However, the EUD was

  11. The Role of Electron Transport and Trapping in MOS Total-Dose Modeling

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Winokur, P.S.; Riewe, L.C.; Flament, O.; Paillet, P.; Leray, J.L.

    1999-01-01

    Radiation-induced hole and electron transport and trapping are fundamental to MOS total-dose models. Here we separate the effects of electron-hole annihilation and electron trapping on the neutralization of radiation-induced charge during switched-bias irradiation for hard and soft oxides, via combined thermally stimulated current (TSC) and capacitance-voltage measurements. We also show that present total-dose models cannot account for the thermal stability of deeply trapped electrons near the Si/SiO 2 interface, or the inability of electrons in deep or shallow traps to contribute to TSC at positive bias following (1) room-temperature, (2) high-temperature, or (3) switched-bias irradiation. These results require revisions of modeling parameters and boundary conditions for hole and electron transport in SiO 2 . The nature of deep and shallow electron traps in the near-interfacial SiO 2 is discussed

  12. Estimation of doses to patients with chronic radiation sickness from external occupational exposure

    International Nuclear Information System (INIS)

    Jia Delin; Dai Guangfu

    1991-01-01

    The doses to patients with chronic radiation sickness who had engaged in diagnostic radiology have been estimated according to the radiation work load, type and capacity of X-ray equipment, protection conditions, data of nationwide survey on doses to X-ray workers in China, or the data of dose monitoring in working places. Based on the activities of radium sources, time taken up in performing radium therapy, distance to radium sources and radiation work load, the doses to patients who had engaged in radium therapy have been estimated. The results of estimated average doses for 29 cases of chronic radiation sickness are given. Their average red marrow dose, trunk dose and effective dose equivalent are 1.3 Gy, 1.2 Gy and 1.6 Sv, respectively

  13. Revisiting Low-Dose Total Skin Electron Beam Therapy in Mycosis Fungoides

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Cameron, E-mail: cameronh@stanford.edu [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Young, James; Navi, Daniel [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Riaz, Nadeem [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States); Lingala, Bharathi; Kim, Youn [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Hoppe, Richard [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States)

    2011-11-15

    Purpose: Total skin electron beam therapy (TSEBT) is a highly effective treatment for mycosis fungoides (MF). The standard course consists of 30 to 36 Gy delivered over an 8- to 10-week period. This regimen is time intensive and associated with significant treatment-related toxicities including erythema, desquamation, anhydrosis, alopecia, and xerosis. The aim of this study was to identify a lower dose alternative while retaining a favorable efficacy profile. Methods and Materials: One hundred two MF patients were identified who had been treated with an initial course of low-dose TSEBT (5-<30 Gy) between 1958 and 1995. Patients had a T stage classification of T2 (generalized patch/plaque, n = 51), T3 (tumor, n = 29), and T4 (erythrodermic, n = 22). Those with extracutaneous disease were excluded. Results: Overall response (OR) rates (>50% improvement) were 90% among patients with T2 to T4 disease receiving 5 to <10 Gy (n = 19). In comparison, OR rates between the 10 to <20 Gy and 20 to <30 Gy subgroups were 98% and 97%, respectively. There was no significant difference in median progression free survival (PFS) in T2 and T3 patients when stratified by dose group, and PFS in each was comparable to that of the standard dose. Conclusions: OR rates associated with low-dose TSEBT in the ranges of 10 to <20 Gy and 20 to <30 Gy are comparable to that of the standard dose ({>=} 30 Gy). Efficacy measures including OS, PFS, and RFS are also favorable. Given that the efficacy profile is similar between 10 and <20 Gy and 20 and <30 Gy, the utility of TSEBT within the lower dose range of 10 to <20 Gy merits further investigation, especially in the context of combined modality treatment.

  14. Total dose induced latch in short channel NMOS/SOI transistors

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Quoizola, S.; Musseau, O.; Flament, O.; Leray, J.L.; Pelloie, J.L.; Raynaud, C.; Faynot, O.

    1998-01-01

    A latch effect induced by total dose irradiation is observed in short channel SOI transistors. This effect appears on NMOS transistors with either a fully or a partially depleted structure. It is characterized by a hysteresis behavior of the Id-Vg characteristics at high drain bias for a given critical dose. Above this dose, the authors still observe a limited leakage current at low drain bias (0.1 V), but a high conduction current at high drain bias (2 V) as the transistor should be in the off-state. The critical dose above which the latch appears strongly depends on gate length, transistor structure (fully or partially depleted), buried oxide thickness and supply voltage. Two-dimensional (2D) numerical simulations indicate that the parasitic condition is due to the latch of the back gate transistor triggered by charge trapping in the buried oxide. To avoid the latch induced by the floating body effect, different techniques can be used: doping engineering, body contacts, etc. The study of the main parameters influencing the latch (gate length, supply voltage) shows that the scaling of technologies does not necessarily imply an increased latch sensitivity. Some technological parameters like the buried oxide hardness and thickness can be used to avoid latch, even at high cumulated dose, on highly integrated SOI technologies

  15. Calculation error of collective effective dose of external exposure during works at 'Shelter' object

    International Nuclear Information System (INIS)

    Batij, V.G.; Derengovskij, V.V.; Kochnev, N.A.; Sizov, A.A.

    2001-01-01

    Collective effective dose (CED) error assessment is the most important task for optimal planning of works in the 'Shelter' object conditions. The main components of CED error are as follows: error in transient factor determination from exposition dose to equivalent dose; error in working hours determination in 'Shelter' object conditions; error in determination of dose rate at workplaces; additional CED error introduced by shielding of workplaces

  16. Test methods of total dose effects in very large scale integrated circuits

    International Nuclear Information System (INIS)

    He Chaohui; Geng Bin; He Baoping; Yao Yujuan; Li Yonghong; Peng Honglun; Lin Dongsheng; Zhou Hui; Chen Yusheng

    2004-01-01

    A kind of test method of total dose effects (TDE) is presented for very large scale integrated circuits (VLSI). The consumption current of devices is measured while function parameters of devices (or circuits) are measured. Then the relation between data errors and consumption current can be analyzed and mechanism of TDE in VLSI can be proposed. Experimental results of 60 Co γ TDEs are given for SRAMs, EEPROMs, FLASH ROMs and a kind of CPU

  17. Total skin electron irradiation: evaluation of dose uniformity throughout the skin surface

    International Nuclear Information System (INIS)

    Anacak, Yavuz; Arican, Zumre; Bar-Deroma, Raquel; Tamir, Ada; Kuten, Abraham

    2003-01-01

    In this study, in vivo dosimetic data of 67 total skin electron irradiation (TSEI) treatments were analyzed. Thermoluminescent dosimetry (TLD) measurements were made at 10 different body points for every patient. The results demonstrated that the dose inhomogeneity throughout the skin surface is around 15%. The homogeneity was better at the trunk than at the extratrunk points, and was worse when a degrader was used. There was minimal improvement of homogeneity in subsequent days of treatment

  18. External exposure dose of car mechanics during the maintenance of the cars from the risk cautionary area

    International Nuclear Information System (INIS)

    Kawakami, Hiroto; Yamada, Norikazu; Sasaki, Satoru; Kawasaki, Satoru

    2011-12-01

    At the request of the Local Nuclear Emergency Response Headquarters, JNES has estimated the effective external exposure dose of car mechanics during the maintenance of the cars from the risk cautionary area. JNES investigated the contamination of the cars from the risk cautionary area and of the average cars at Fukushima city cooperated by the Japan Automobile Dealers Association. Data of screed cars by the Local Nuclear Emergency Response Headquarters is also considered in. Effective external exposure dose of car mechanics treating the cars screened with the emergency situation screening level is estimated to be less than 1 mSv/y under the conservative conditions. This result shows that particular health concern isn't necessary for them. (author)

  19. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 7. Organ doses due to parallel and environmental exposure geometries

    Energy Technology Data Exchange (ETDEWEB)

    Zankl, M. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Drexler, G. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Petoussi-Henss, N. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Saito, K. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan)

    1997-03-01

    This report presents a tabulation of organ and tissue equivalent dose as well as effective dose conversion coefficients, normalised to air kerma free in air, for occupational exposures and environmental exposures of the public to external photon radiation. For occupational exposures, whole-body irradiation with idealised geometries, i.e. broad parallel beams and fully isotropic radiation incidence, is considered. The directions of incidence for the parallel beams are anterior-posterior, posterior-anterior, left lateral, right lateral and a full 360 rotation around the body`s longitudinal axis. The influence of beam divergence on the body doses is also considered as well as the dependence of effective dose on the angle of radiation incidence. Regarding exposure of the public to environmental sources, three source geometries are considered: exposure from a radioactive cloud, from ground contamination and from the natural radionuclides distributed homogeneously in the ground. The precise angular and energy distributions of the gamma rays incident on the human body were taken into account. The organ dose conversion coefficients given in this catalogue were calculated using a Monte Carlo code simulating the photon transport in mathematical models of an adult male and an adult female, respectively. Conversion coefficients are given for the equivalent dose of 23 organs and tissues as well as for effective dose and the equivalent dose of the so-called `remainder`. The organ equivalent dose conversion coefficients are given separately for the adult male and female models and - as arithmetic mean of the conversion coefficients of both - for an average adult. Fitted data of the coefficients are presented in tables; the primary raw data as resulting from the Monte Carlo calculation are shown in figures together with the fitted data. (orig.)

  20. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 7. Organ doses due to parallel and environmental exposure geometries

    International Nuclear Information System (INIS)

    Zankl, M.

    1997-03-01

    This report presents a tabulation of organ and tissue equivalent dose as well as effective dose conversion coefficients, normalised to air kerma free in air, for occupational exposures and environmental exposures of the public to external photon radiation. For occupational exposures, whole-body irradiation with idealised geometries, i.e. broad parallel beams and fully isotropic radiation incidence, is considered. The directions of incidence for the parallel beams are anterior-posterior, posterior-anterior, left lateral, right lateral and a full 360 rotation around the body's longitudinal axis. The influence of beam divergence on the body doses is also considered as well as the dependence of effective dose on the angle of radiation incidence. Regarding exposure of the public to environmental sources, three source geometries are considered: exposure from a radioactive cloud, from ground contamination and from the natural radionuclides distributed homogeneously in the ground. The precise angular and energy distributions of the gamma rays incident on the human body were taken into account. The organ dose conversion coefficients given in this catalogue were calculated using a Monte Carlo code simulating the photon transport in mathematical models of an adult male and an adult female, respectively. Conversion coefficients are given for the equivalent dose of 23 organs and tissues as well as for effective dose and the equivalent dose of the so-called 'remainder'. The organ equivalent dose conversion coefficients are given separately for the adult male and female models and - as arithmetic mean of the conversion coefficients of both - for an average adult. Fitted data of the coefficients are presented in tables; the primary raw data as resulting from the Monte Carlo calculation are shown in figures together with the fitted data. (orig.)

  1. External beam abdominal radiotherapy in patients with seminoma stage I: field type, testicular dose, and spermatogenesis

    International Nuclear Information System (INIS)

    Jacobsen, Kari Dolven; Olsen, Dag Rune; Fossaa, Kristian; Fossaa, Sophie Dorothea

    1997-01-01

    Purpose: To establish a predictive model for the estimation of the gonadal dose during adjuvant para-aortic (PA) or dog leg (DL: PA plus ipsilateral iliac) field radiotherapy in patients with testicular seminoma. Methods and Materials: The surface gonadal dose was measured in patients with seminoma Stage I receiving PA or DL radiotherapy. Sperm cell analysis was performed before and 1 year after irradiation. PA and DL radiotherapy were simulated in the Alderson phantom while we measured the dose to the surface and middle of an artificial testicle, varying its position within realistic anatomical constraints. The symphysis-to-testicle distance (STD), field length, and thickness of the patient were experimental variables. The developed mathematical model was validated in subsequent patients. Results: The mean gonadal dose in patients was 0.09 and 0.32 Gy after PA and DL irradiation, respectively (p < 0.001). DL radiotherapy, but not PA irradiation led to significant reduction of the sperm count 1 year after irradiation. The gonadal dose-reducing effect of PA irradiation was confirmed in the Alderson phantom. A significant correlation was found between the STD and the gonadal dose during DL irradiation. A mathematical model was established for calculation of the gonadal dose and confirmed by measurements in patients. Conclusions: During radiotherapy of seminoma, the gonadal dose decreases with increasing STD. It is possible to predict the individual gonadal dose based on delivered midplane dose and STD

  2. The Sandia total-dose estimator: SANDOSE description and user guide

    International Nuclear Information System (INIS)

    Turner, C.D.

    1995-02-01

    The SANdia total-DOSe Estimator (SANDOSE) is used to estimate total radiation dose to a (BRL-CAT) solid model, SANDOSE uses the mass-sectoring technique to sample the model using ray-tracing techniques. The code is integrated directly into the BRL-CAD solid model editor and is operated using a simple graphical user interface. Several diagnostic tools are available to allow the user to analyze the results. Based on limited validation using several benchmark problems, results can be expected to fall between a 10% underestimate and a factor of 2 overestimate of the actual dose predicted by rigorous radiation transport techniques. However, other situations may be encountered where the results might fall outside of this range. The code is written in C and uses X-windows graphics. It presently runs on SUN SPARCstations, but in theory could be ported to any workstation with a C compiler and X-windows. SANDOSE is available via license by contacting either the Sandia National Laboratories Technology Transfer Center or the author

  3. Determination of absorbed dose to the lens of eye from external sources

    International Nuclear Information System (INIS)

    Chen Lishu

    1993-01-01

    The methods of determining absorbed dose distributions in human eyeball by means of the experiments and available theories have been reported. A water phantom was built up. The distributions of beta dose were measured by an extrapolation ionization chamber at some depths corresponding to components of human eyeball such as cornea, sclera, anterior chamber and the lens of eye. The ratios among superficial absorbed dose (at 0.07 mm) and average absorbed doses at the depths 1,2,3 mm are obtained. They can be used for confining the deterministic effects of superficial tissues and organs such as the lens of eye for weakly penetrating radiations

  4. Evaluation of the influence of weather conditions on external dose rate

    International Nuclear Information System (INIS)

    Knight, A.

    1993-01-01

    Six time periods in 1989/90, when there were high gamma ray dose rate readings at three or more RIMNET Phase 1 sites, were selected for detailed study. The high dose rates were compared with meteorological data (rainfall, temperatures, windspeeds and atmospheric pressure) at the sites for the time periods studied. The results using daily and hourly data clearly show a correlation between gamma ray dose rate and rainfall but not with the other meteorological parameters studied. The increase in dose rate with increased rainfall is believed to be due to radon decay products being washed down with heavy rain. (author)

  5. Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Scott E., E-mail: sedavids@utmb.edu [Radiation Oncology, The University of Texas Medical Branch, Galveston, Texas 77555 (United States); Cui, Jing [Radiation Oncology, University of Southern California, Los Angeles, California 90033 (United States); Kry, Stephen; Ibbott, Geoffrey S.; Followill, David S. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Deasy, Joseph O. [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States); Vicic, Milos [Department of Applied Physics, University of Belgrade, Belgrade 11000 (Serbia); White, R. Allen [Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

    2016-08-15

    Purpose: A dose calculation tool, which combines the accuracy of the dose planning method (DPM) Monte Carlo code and the versatility of a practical analytical multisource model, which was previously reported has been improved and validated for the Varian 6 and 10 MV linear accelerators (linacs). The calculation tool can be used to calculate doses in advanced clinical application studies. One shortcoming of current clinical trials that report dose from patient plans is the lack of a standardized dose calculation methodology. Because commercial treatment planning systems (TPSs) have their own dose calculation algorithms and the clinical trial participant who uses these systems is responsible for commissioning the beam model, variation exists in the reported calculated dose distributions. Today’s modern linac is manufactured to tight specifications so that variability within a linac model is quite low. The expectation is that a single dose calculation tool for a specific linac model can be used to accurately recalculate dose from patient plans that have been submitted to the clinical trial community from any institution. The calculation tool would provide for a more meaningful outcome analysis. Methods: The analytical source model was described by a primary point source, a secondary extra-focal source, and a contaminant electron source. Off-axis energy softening and fluence effects were also included. The additions of hyperbolic functions have been incorporated into the model to correct for the changes in output and in electron contamination with field size. A multileaf collimator (MLC) model is included to facilitate phantom and patient dose calculations. An offset to the MLC leaf positions was used to correct for the rudimentary assumed primary point source. Results: Dose calculations of the depth dose and profiles for field sizes 4 × 4 to 40 × 40 cm agree with measurement within 2% of the maximum dose or 2 mm distance to agreement (DTA) for 95% of the data

  6. Pattern imprinting in deep sub-micron static random access memories induced by total dose irradiation

    International Nuclear Information System (INIS)

    Zheng Qi-Wen; Yu Xue-Feng; Cui Jiang-Wei; Guo Qi; Ren Di-Yuan; Cong Zhong-Chao; Zhou Hang

    2014-01-01

    Pattern imprinting in deep sub-micron static random access memories (SRAMs) during total dose irradiation is investigated in detail. As the dose accumulates, the data pattern of memory cells loading during irradiation is gradually imprinted on their background data pattern. We build a relationship between the memory cell's static noise margin (SNM) and the background data, and study the influence of irradiation on the probability density function of ΔSNM, which is the difference between two data sides' SNMs, to discuss the reason for pattern imprinting. Finally, we demonstrate that, for micron and deep sub-micron devices, the mechanism of pattern imprinting is the bias-dependent threshold shift of the transistor, but for a deep sub-micron device the shift results from charge trapping in the shallow trench isolation (STI) oxide rather than from the gate oxide of the micron-device. (condensed matter: structural, mechanical, and thermal properties)

  7. Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

    International Nuclear Information System (INIS)

    Martin, K.E.; Gauthier, M.K.; Coss, J.R.; Dantas, A.R.V.; Price, W.E.

    1986-05-01

    Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose

  8. Pattern imprinting in deep sub-micron static random access memories induced by total dose irradiation

    Science.gov (United States)

    Zheng, Qi-Wen; Yu, Xue-Feng; Cui, Jiang-Wei; Guo, Qi; Ren, Di-Yuan; Cong, Zhong-Chao; Zhou, Hang

    2014-10-01

    Pattern imprinting in deep sub-micron static random access memories (SRAMs) during total dose irradiation is investigated in detail. As the dose accumulates, the data pattern of memory cells loading during irradiation is gradually imprinted on their background data pattern. We build a relationship between the memory cell's static noise margin (SNM) and the background data, and study the influence of irradiation on the probability density function of ΔSNM, which is the difference between two data sides' SNMs, to discuss the reason for pattern imprinting. Finally, we demonstrate that, for micron and deep sub-micron devices, the mechanism of pattern imprinting is the bias-dependent threshold shift of the transistor, but for a deep sub-micron device the shift results from charge trapping in the shallow trench isolation (STI) oxide rather than from the gate oxide of the micron-device.

  9. Calculation of the external dose rate in the spent fuel pool for the case to use compact racks

    International Nuclear Information System (INIS)

    Passos, E.M. dos; Alves, A.S.M.

    1988-01-01

    The possible introduction of compact racks in the spent fuel pool of the Angra 1 Nuclear Power Plant largely inreases its storage capacity, but originates an increase of the gamma radiation sources. The precise evaluation of the effects of the adoption of this option on the external gamma dose rates and also on the thickness of the concrete shielding requires the utilization of sofisticated computer codes (QAD, ANISN), which allow the calculation of the gamma dose rates through thick shielding walls. This paper describes the utilized methodology for the calculation of the modified pool shieldings, showing the obtained results for the Angra 1 NPP case. The gamma dose rate was calculated with the point Kernel model, first analytically, and later through utilization of the tridimensional multigroup QAD computer code. (author) [pt

  10. DEEP code to calculate dose equivalents in human phantom for external photon exposure by Monte Carlo method

    International Nuclear Information System (INIS)

    Yamaguchi, Yasuhiro

    1991-01-01

    The present report describes a computer code DEEP which calculates the organ dose equivalents and the effective dose equivalent for external photon exposure by the Monte Carlo method. MORSE-CG, Monte Carlo radiation transport code, is incorporated into the DEEP code to simulate photon transport phenomena in and around a human body. The code treats an anthropomorphic phantom represented by mathematical formulae and user has a choice for the phantom sex: male, female and unisex. The phantom can wear personal dosimeters on it and user can specify their location and dimension. This document includes instruction and sample problem for the code as well as the general description of dose calculation, human phantom and computer code. (author)

  11. External radiation doses from deposed fly ash with a content of 40K, 226Ra and 232Th

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.

    1991-12-01

    Fly ash from coal fired power plants might be used as filling material below buildings used for habitation. The fly ash content of the radionuclides of potassium, thorium and radium can cause external exposure of the inhabitants to γ radiation emitted during the radioactive decay of those radionuclides. Methods for calculation of the γ dose rate in air at indoor and outdoor positions are described. The dependence of the air dose rate on the vertical and horizontal dimensions of the fly ash material and on the thickness of a covering layer of soil or sand is analysed. The effective annual dose to inhabitants are calculated for typical Danish housing conditions with the buildings placed on a layer of fly ash of infinite vertical and horizontal dimensions and covered by soil or sand of varying thickness. (au) 10 refs

  12. Prostate cancer: variables to keep in mind at the moment to decide the external radiotherapy dose

    International Nuclear Information System (INIS)

    Donato, H.; Barros, J.M.; Fernandez Bibiloni, C.; Barrios, E.; Martinez, A.; Broda, E.; Cardiello, C.; Alva, R.; Chiozza, J.; Filomia, M.L.; Rafailovici, L.; Dosoretz, B.

    2007-01-01

    The objective of this work is to evaluate forecast factors and other variables in the decision of the final dose for prostate cancer treatment with 3D conformal radiotherapy techniques of modulated intensity. To determine the optimal dose, direct and indirect variables related to the disease should be considered. Also the equipment and the radiotherapy technique will impact on this decision [es

  13. Basis for calculating body equivalent doses after external radiation exposure. 3. rev. and enl. ed.; Berechnungsgrundlage fuer die Ermittlung von Koerper-Aequivalentdosen bei aeusserer Strahlenexposition

    Energy Technology Data Exchange (ETDEWEB)

    Sarenio, O. (comp.) [Geschaeftsstelle der Strahlenschutzkommission beim Bundesamt fuer Strahlenschutz, Bonn (Germany)

    2017-07-01

    The book on the basis for calculating body equivalent doses after external radiation exposure includes the following issues: introduction covering the scope of coverage and body equivalent doses for radiation protection, terminology, photon radiation, neutron radiation, electron radiation, mixed radiation fields and the estimation of body equivalent doses for skin surface contamination.

  14. Low-dose-rate intraoperative brachytherapy combined with external beam irradiation in the conservative treatment of soft tissue sarcoma

    International Nuclear Information System (INIS)

    Delannes, M.; Thomas, L.; Martel, P.; Bonnevialle, P.; Stoeckle, E.; Chevreau, Ch.; Bui, B.N.; Daly-Schveitzer, N.; Pigneux, J.; Kantor, G.

    2000-01-01

    Purpose: Conservative treatment of soft tissue sarcomas most often implies combination of surgical resection and irradiation. The aim of this study was to evaluate low-dose-rate intraoperative brachytherapy, delivered as a boost, in the local control of primary tumors, with special concern about treatment complications. Methods and Materials: Between 1986 and 1995, 112 patients underwent intraoperative implant. This report focuses on the group of 58 patients with primary sarcomas treated by combination of conservative surgery, intraoperative brachytherapy, and external irradiation. Most of the tumors were located in the lower limbs (46/58--79%). Median size of the tumor was 10 cm, most of the lesions being T2-T3 (51/58--88%), Grade 2 or 3 (48/58--83%). The mean brachytherapy dose was 20 Gy and external beam irradiation dose 45 Gy. In 36/58 cases, iridium wires had to be placed on contact with neurovascular structures. Results: With a median follow-up of 54 months, the 5-year actuarial survival was 64.9%, with a 5-year actuarial local control of 89%. Of the 6 patients with local relapse, 3 were salvaged. Acute side effects, essentially wound healing problems, occurred in 20/58 patients, late side effects in 16/58 patients (7 neuropathies G2 to G4). No amputation was required. The only significant factor correlated with early side effects was the location of the tumor in the lower limb (p = 0.003), and with late side effects the vicinity of the tumor with neurovascular structures (p = 0.009). Conclusion: Brachytherapy allows early delivery of a boost dose in a reduced volume of tissue, precisely mapped by the intraoperative procedure. Combined with external beam irradiation, it is a safe and efficient treatment technique leading to high local control rates and limited functional impairment

  15. The review of radiation effects of γ total dose in CMOS circuits

    International Nuclear Information System (INIS)

    Chen Panxun; Gao Wenming; Xie Zeyuan; Mi Bang

    1992-01-01

    Radiation performances of commercial and rad-hard CMOS circuits are reviewed. Threshold voltage, static power current, V in -V out characteristic and propagation delay time related with total dose are presented for CMOS circuits from several manufacturing processes. The performance of radiation-annealing of experimental circuits had been observed for two years. The comparison has been made between the CMOS circuits made in China and the commercial RCA products. 60 Co γ source can serve as γ simulator of the nuclear explosion

  16. Unscheduled DNA synthesis in spleen cells of mice exposed to low doses of total body irradiation

    International Nuclear Information System (INIS)

    Tuschl, H.; Kovac, R.; Hruby, E.

    1983-07-01

    Unscheduled DNA synthesis was induced by UV irradiation of spleen cells obtained from C 57 Bl mice after repeated total body irradiation of 0.05 Gy 60 Co (0.00125 Gy/mice) and determined autoradiographically. An enhancement in the ability for repair of UV induced DNA lesions was observed in cells of gamma irradiated animals. While the amount of 3 H-thymidine incorporated per cell was increased, the percentage of labeled cells remained unchanged. The present results are compared with previous data on low dose radiation exposure in men. (Author) [de

  17. Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Wu, Vincent W.C.; Yang Zhining; Zhang Wuzhe; Wu Lili; Lin Zhixiong

    2012-01-01

    This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.

  18. Evaluation of off-axis wedge correction factor using diode dosimeters for estimation of delivered dose in external radiotherapy

    International Nuclear Information System (INIS)

    Allahverdi, Mahmoud; Shirazi, Alireza; Geraily, Ghazale; Mohammadkarim, Alireza; Esfehani, Mahbod; Nedaie, Hasanali

    2012-01-01

    An in vivo dosimetry system, using p-type diode dosimeters, was characterized for clinical applications of treatment machines ranging in megavoltage energies. This paper investigates two different models of diodes for externally wedged beams and explains a new algorithm for the calculation of the target dose at various tissue depths in external radiotherapy. The values of off-axis wedge correction factors were determined at two different positions in the wedged (toward the thick and thin edges) and in the non-wedged directions on entrance and exit surfaces of a polystyrene phantom in 60 Co and 6 MV photon beams. Depth transmission was defined on the entrance and exit surfaces to obtain the off-axis wedge correction factor at any depth. As the sensitivity of the diodes depends on physical characteristics (field size, source-skin distance (SSD), thickness, backscatter), correction factors were applied to the diode reading when measuring conditions different from calibration situations. The results indicate that needful correction factors for 60 Co wedged photons are usually larger than those for 6 MV wedged photon beams. In vivo dosimetry performed with the proposed algorithms at externally wedged beams has negligible probable errors (less than 0.5%) and is a reliable method for patient dose control. (author)

  19. Evaluation of off-axis wedge correction factor using diode dosimeters for estimation of delivered dose in external radiotherapy

    Directory of Open Access Journals (Sweden)

    Mahmoud Allahverdi

    2012-01-01

    Full Text Available An in vivo dosimetry system, using p-type diode dosimeters, was characterized for clinical applications of treatment machines ranging in megavoltage energies. This paper investigates two different models of diodes for externally wedged beams and explains a new algorithm for the calculation of the target dose at various tissue depths in external radiotherapy. The values of off-axis wedge correction factors were determined at two different positions in the wedged (toward the thick and thin edges and in the non-wedged directions on entrance and exit surfaces of a polystyrene phantom in 60 Co and 6 MV photon beams. Depth transmission was defined on the entrance and exit surfaces to obtain the off-axis wedge correction factor at any depth. As the sensitivity of the diodes depends on physical characteristics [field size, source-skin distance (SSD, thickness, backscatter], correction factors were applied to the diode reading when measuring conditions different from calibration situations . The results indicate that needful correction factors for 60 Co wedged photons are usually larger than those for 6 MV wedged photon beams. In vivo dosimetry performed with the proposed algorithms at externally wedged beams has negligible probable errors (less than 0.5% and is a reliable method for patient dose control.

  20. The biological effects of high dose total body irradiation in beagle dogs

    International Nuclear Information System (INIS)

    Luo Qingliang; Liu Xiaolan; Hao Jing; Xiong Guolin; Dong Bo; Zhao Zhenhu; Xia Zhengbiao; Qiu Liling; Mao Bingzhi

    2002-01-01

    Objective: To evaluate the biological effects of Beagle dogs irradiated by γ-rays at different doses. Methods: All Beagle dogs were divided into six groups and were subjected respectively to total-body irradiation (TBI) with a single dose of 6.5, 5.5, 5.0, 4.5, 3, 5 and 2.5 Gy γ-rays delivered by 60 Co sources at 7.224 x 10 -2 C/kg per minute. The general condition, blood cell counts and bone marrow cell CFC assays were observed. Results: Vomiting occurred at 0.5 to 2 hours after TBI in all groups. In 6.5 Gy group 3/5 dogs had blood-watery stool and 1/5 in 5.5 Gy group had watery stool. Diarrhea occurred in all other animals. Only one dog in 2.5 Gy group survived, all of others died. in order of decreasing irradiation dosage, the average survival time was 5.0, 8.0, 9.3, 9.5, 10.5 and 14.1 days, respectively. Conclusions: According to the clinical symptoms, leukocyte count and survival time of the dogs, the irradiation dose which will induce very severe hematopoietic radiation syndrome in Beagle dogs is 4.5 to 5.0 Gy

  1. The effect of low-dose total body irradiation on tumor control

    International Nuclear Information System (INIS)

    Sakamoto, Kiyohiko; Miyamoto, Miyako; Watabe, Nobuyuki.

    1987-01-01

    Total body irradiation (TBI) is considered to bring about an immunosuppressive effect on an organism, on the basis of data obtained from sublethal doses of TBI. However, there are no data on how low-dose TBI affects an organism. Over the last five years, we have been studying the effects of low-dose TBI on normal or tumor-bearing mice and the immunological background of these effects. In experimental studies, an increase in the TD50 value (the number of cells required for a tumor incidence of 50 %) in mice exposed to 10 rad was recognized and showed a remarkable increase at 6 hours to 15 hours after irradiation. TBI of 10 rad also showed an enhancement effect on tumor cell killing when given 12 hours before local tumor irradiation. In order to clarify the mechanism of this kind of effect, some immunological studies were performed using several immunological procedures, and the results suggested that 10 rad of TBI caused increasing tumor immunity in irradiated mice. Clinical trials in some patients with advanced tumors are now being undertaken on the basis of these experimental data, and the effect of TBI on tumor control appears promising, although it is too early to draw conclusions. (author)

  2. Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation

    International Nuclear Information System (INIS)

    Kal, H.B.; Kempen-Harteveld, M.L. van; Heijenbrok-Kal, M.H.; Struikmans, H.

    2006-01-01

    Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled relative risk (RR) was calculated for the treatments with high BED values versus treatments with a low BED. BED-effect relationships were obtained. Results: RRs for the high BED treatments were significantly lower for relapse incidence, not significantly different for disease-free survival and treatment-related mortality, and significantly higher for overall survival. BED-effect relationships indicate a decrease in relapse incidence and treatment-related mortality and an increase in disease-free and overall survival with higher BED values. Conclusion: 'More dose is better', provided that a TBI setting is used limiting the BEDs of lungs, kidneys, and eye lenses. (orig.)

  3. In pediatric leukemia, dose evaluation according to the type of compensators in total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yeon [Dongnam Inst. of Radiological and Medical science, Busan (Korea, Republic of); Kim, Chang Soo; Kim, Jung Hoon [Dept. of Radiological Science, College of Health Science, Catholic University of Busan, Busan (Korea, Republic of)

    2015-04-15

    Total body irradiation (TBI) and chemotherapy are the pre-treatment method of a stem cell transplantations of the childhood leukemia. in this study, we evaluate the Quantitative human body dose prior to the treatment. The MCNPX simulation program evaluated by changing the material of the tissue compensators with imitation material of pediatric exposure in a virtual space. As a result, first, the average skin dose with the material of the tissue compensators of Plexiglass tissue compensators is 74.60 mGy/min, Al is 73.96 mGy/min, Cu is 72.26 mGy/min and Pb 67.90 mGy/min respectively. Second, regardless of the tissue compensators material that organ dose were thyroid, gentile, digestive system, brain, lungs, kidneys higher in order. Finally, the ideal distance between body compensator and the patient were 50 cm aparting each other. In conclusion, tissue compensators Al, Cu, Pb are able to replace of the currently used in Plexiglass materials.

  4. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars

    2015-01-01

    a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. RESULTS: The overall response rate was 95% with a complete cutaneous response......PURPOSE: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments...... or a very good partial response rate (response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. CONCLUSIONS...

  5. Modeling for Dose Rate Calculation of the External Exposure to Gamma Emitters in Soil

    International Nuclear Information System (INIS)

    Allam, K. A.; El-Mongy, S. A.; El-Tahawy, M. S.; Mohsen, M. A.

    2004-01-01

    Based on the model proposed and developed in Ph.D thesis of the first author of this work, the dose rate conversion factors (absorbed dose rate in air per specific activity of soil in nGy.hr - 1 per Bq.kg - 1) are calculated 1 m above the ground for photon emitters of natural radionuclides uniformly distributed in the soil. This new and simple dose rate calculation software was used for calculation of the dose rate in air 1 m above the ground. Then the results were compared with those obtained by five different groups. Although the developed model is extremely simple, the obtained results of calculations, based on this model, show excellent agreement with those obtained by the above-mentioned models specially that one adopted by UNSCEAR. (authors)

  6. DETERMINATION OF SUPERFICIAL ABSORBED DOSE FROM EXTERNAL EXPOSURE OF WEAKLY PENETRATING RADIATIONS

    Institute of Scientific and Technical Information of China (English)

    陈丽姝

    1994-01-01

    The methods of determining the superficial absorbed dose distributions in a water phantom by means of the experiments and available theories have been reported.The distributions of beta dose were measured by an extrapolation ionization chamber at definite depthes corresponding to some superficial organs and tissues such as the radiosensitive layer of the skin,cornea,sclera,anterior chamber and lens of eyeball.The ratios among superficial absorbed dose D(0.07) and average absorbed doses at the depthes 1,2,3,4,5 and 6mm are also obtained with Cross's methods.They can be used for confining the deterministic effects of some superficial tissues and organs such as the skin and the components of eyeball for weakly penetrating radiations.

  7. Low-dose external beam radiotherapy for greater trochanteric pain syndrome. Target volume definition and treatment outcome

    International Nuclear Information System (INIS)

    Kaltenborn, Alexander; Carl, Ulrich Martin; Hinsche, Tanja; Nitsche, Mirko; Hermann, Robert Michael

    2017-01-01

    Low-dose external beam radiotherapy (ED-EBRT) is frequently used in the therapy of refractory greater trochanteric pain syndrome (GTPS). As studies reporting treatment results are scarce, we retrospectively analyzed our own patient collectives. In all, 60 patients (74 hips) received LD-EBRT (6 x 0.5 Gy in 29 hips, 6 x 1 Gy in 45). The endpoint was the patient's reported subjective response to treatment. The influence of different patient and treatment characteristics on treatment outcome was investigated. At the end of LD-EBRT, 69% reported partial remission, 4% complete remission, no change 28%. A total of 3 months later (n = 52 hips), the results were 37, 33, and 30% and 18 months after LD-EBRT (n = 47) 21, 51, and 28%. In univariate analysis ''inclusion of the total femoral head into the PTV'' and ''night pain before LD-EBRT'' were correlated with symptom remission at the end of LD-EBRT, while ''initial increase in pain during LD-EBRT'' was significantly associated with treatment failure. In multivariable modeling ''initial increase in pain'' was identified as a risk factor for treatment failure (p = 0.007; odds ratio [OR] 0.209; 95% confidence interval [CI] 0.048-0.957), while ''night pain'' was an independent factor for remission (p = 0.038; OR 3.484; 95% CI 1.004-12.6). Three months after LD-EBRT ''night pain'' and ''inclusion of the complete femoral neck circumference into the PTV'' were predictive for remission. LD-EBRT represents a useful treatment option for patients suffering from GTPS. Three months after therapy two-thirds of the patients reported a partial or complete symptom remission. Especially patients who suffered from nocturnal pain seemed to benefit. Treatment appeared to be more effective when the entire circumference of the femoral neck was encompassed. (orig.) [de

  8. 3D Dose Reconstruction to Insure Correct External Beam Treatment of Patients

    International Nuclear Information System (INIS)

    Renner, Wendel Dean

    2007-01-01

    Radiation therapy treatments have become increasingly more complicated. There are multiple opportunities for humans, machines, software, and combinations thereof to result in a treatment error that could be of significance. Current methods for quality assurance are often abstract in nature and may have unclear underlying assumptions as to what is assumed to be working correctly, or may depend upon the diligence of persons to discover errors from a review of the treatment plan. Here, an example will be shown of a direct method to reconstruct and demonstrate the dose and the dose distribution delivered to a particular patient. By measuring the radiation fields that come out of the accelerator, and using the measurement as input to a 3-dimensional (3D) dose algorithm, the delivered patient dose is determined and presented in a manner similar to the treatment plan. The intended treatment plan dose may be directly compared. Using this feedback mechanism, there is less abstraction and dependence upon the diligence of individuals checking multiple steps in a treatment process, and assumptions can be clearly stated. With this system, the dose is determined and presented minimizing assumptions and dependence upon other systems

  9. Modelling of an industrial environment, part 2.: External dose calculation with relevant countermeasures

    International Nuclear Information System (INIS)

    Eged, K.; Kis, Z.; Alvarez-Farizo, B.; Gil, J.; Voigt, G.

    2002-01-01

    The calculation of the collective dose and averted collective dose after applying countermeasures in an industrial environment has been divided in two parts. In the first part (Kis et al. 2002) separate Monte Carlo simulations of photon transport resulted in the air kermas per photon per unit area due to the industrial surfaces contaminated by 1 37C s at specific points using the so-called local approach. In the local approach the air kerma rates due to specific intervention elements at the evaluation locations in the whole environment are determined (Gutierrez et al. 2000). In this way the collective and averted collective dose due to the radiation from a particular intervention element (e.g. the roof of a building) can be obtained. It can, therefore, provide a ranking of the specific intervention elements based on their contribution to collective dose as well. The deposition pattern and the long-term behaviour of deposited radionuclides vary widely in natural circumstances; therefore the number of the photons emitted from the various surfaces per unit area and time can differ significantly. This means the results of the Monte Carlo simulations have to be weighted according to the number of emitted photons so that the actual radiation field can be set up. For this purpose, a dose calculation code has been developed in the framework of the TEMAS project (Gutierrez et al. 2000) which allows to calculate collective doses for different environments. This code has been applied in the present work

  10. A first-principles approach to total-dose hardness assurance

    International Nuclear Information System (INIS)

    Fleetwood, D.M.

    1995-01-01

    A first-principles approach to radiation hardness assurance was described that provides the technical background to the present US and European total-dose radiation hardness assurance test methods for MOS technologies, TM 1019.4 and BS 22900. These test methods could not have been developed otherwise, as their existence depends not on a wealth of empirical comparisons of IC data from ground and space testing, but on a fundamental understanding of MOS defect growth and annealing processes. Rebound testing should become less of a problem for advanced MOS small-signal electronics technologies for systems with total dose requirements below 50--100 krad(SiO 2 ) because of trends toward much thinner gate oxides. For older technologies with thicker gate oxides and for power devices, rebound testing is unavoidable without detailed characterization studies to assess the impact of interface traps on devices response in space. The QML approach is promising for future hardened technologies. A sufficient understanding of process effects on radiation hardness has been developed that should be able to reduce testing costs in the future for hardened parts. Finally, it is hoped that the above discussions have demonstrated that the foundation for cost-effective hardness assurance tests is laid with studies of the basic mechanisms of radiation effects. Without a diligent assessment of new radiation effects mechanisms in future technologies, one cannot be assured that the present generation of radiation test standards will continue to apply

  11. A rapid infusion protocol is safe for total dose iron polymaltose: time for change.

    Science.gov (United States)

    Garg, M; Morrison, G; Friedman, A; Lau, A; Lau, D; Gibson, P R

    2011-07-01

    Intravenous correction of iron deficiency by total dose iron polymaltose is inexpensive and safe, but current protocols entail prolonged administration over more than 4 h. This results in reduced patient acceptance, and hospital resource strain. We aimed to assess prospectively the safety of a rapid intravenous protocol and compare this with historical controls. Consecutive patients in whom intravenous iron replacement was indicated were invited to have up to 1.5 g iron polymaltose by a 58-min infusion protocol after an initial 15-min test dose without pre-medication. Infusion-related adverse events (AE) and delayed AE over the ensuing 5 days were also prospectively documented and graded as mild, moderate or severe. One hundred patients, 63 female, mean age 54 (range 18-85) years were studied. Thirty-four infusion-related AE to iron polymaltose occurred in a total of 24 patients--25 mild, 8 moderate and 1 severe; higher than previously reported for a slow protocol iron infusion. Thirty-one delayed AE occurred in 26 patients--26 mild, 3 moderate and 2 severe; similar to previously reported. All but five patients reported they would prefer iron replacement through the rapid protocol again. The presence of inflammatory bowel disease (IBD) predicted infusion-related reactions (54% vs 14% without IBD, P cost, resource utilization and time benefits for the patient and hospital system. © 2011 The Authors. Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  12. Influence of burn-in on total-ionizing-dose effect of SRAM device

    International Nuclear Information System (INIS)

    Liu Minbo; Yao Zhibin; Huang Shaoyan; He Baoping; Sheng Jiangkun

    2014-01-01

    The influence of Burn-in on the total-ionizing-dose (TID) effect of SRAM device was investigated. SRAM devices of three different feature sizes were selected and irradiated by "6"0Co source with or without pre-irradiation Burn-in. Some parameters for radiation effect of SRAM device such as upset data, were measured, and the influence on the TID effect of different feature size SRAM devices with or without pre-irradiation Burn-in was obtained. The influence of different temperature Burn-in on radiation resistant capability of SRAM device was studied for 0.25 μm SRAM device. The results show that the smaller the device feature size is, the better the radiation-resistant capability of SRAM device is and the weaker the influence of Burn-in is. And the higher Burn-in temperature is, the more serious the influence of Burn-in on the total-dose radiation effect is. (authors)

  13. Total Ambient Dose Equivalent Buildup Factor Determination for Nbs04 Concrete.

    Science.gov (United States)

    Duckic, Paulina; Hayes, Robert B

    2018-06-01

    Buildup factors are dimensionless multiplicative factors required by the point kernel method to account for scattered radiation through a shielding material. The accuracy of the point kernel method is strongly affected by the correspondence of analyzed parameters to experimental configurations, which is attempted to be simplified here. The point kernel method has not been found to have widespread practical use for neutron shielding calculations due to the complex neutron transport behavior through shielding materials (i.e. the variety of interaction mechanisms that neutrons may undergo while traversing the shield) as well as non-linear neutron total cross section energy dependence. In this work, total ambient dose buildup factors for NBS04 concrete are calculated in terms of neutron and secondary gamma ray transmission factors. The neutron and secondary gamma ray transmission factors are calculated using MCNP6™ code with updated cross sections. Both transmission factors and buildup factors are given in a tabulated form. Practical use of neutron transmission and buildup factors warrants rigorously calculated results with all associated uncertainties. In this work, sensitivity analysis of neutron transmission factors and total buildup factors with varying water content has been conducted. The analysis showed significant impact of varying water content in concrete on both neutron transmission factors and total buildup factors. Finally, support vector regression, a machine learning technique, has been engaged to make a model based on the calculated data for calculation of the buildup factors. The developed model can predict most of the data with 20% relative error.

  14. Dose-Volume Parameters of the Corpora Cavernosa Do Not Correlate With Erectile Dysfunction After External Beam Radiotherapy for Prostate Cancer: Results From a Dose-Escalation Trial

    International Nuclear Information System (INIS)

    Wielen, Gerard J. van der; Hoogeman, Mischa S.; Dohle, Gert R.; Putten, Wim L.J. van; Incrocci, Luca

    2008-01-01

    Purpose: To analyze the correlation between dose-volume parameters of the corpora cavernosa and erectile dysfunction (ED) after external beam radiotherapy (EBRT) for prostate cancer. Methods and Materials: Between June 1997 and February 2003, a randomized dose-escalation trial comparing 68 Gy and 78 Gy was conducted. Patients at our institute were asked to participate in an additional part of the trial evaluating sexual function. After exclusion of patients with less than 2 years of follow-up, ED at baseline, or treatment with hormonal therapy, 96 patients were eligible. The proximal corpora cavernosa (crura), the superiormost 1-cm segment of the crura, and the penile bulb were contoured on the planning computed tomography scan and dose-volume parameters were calculated. Results: Two years after EBRT, 35 of the 96 patients had developed ED. No statistically significant correlations between ED 2 years after EBRT and dose-volume parameters of the crura, the superiormost 1-cm segment of the crura, or the penile bulb were found. The few patients using potency aids typically indicated to have ED. Conclusion: No correlation was found between ED after EBRT for prostate cancer and radiation dose to the crura or penile bulb. The present study is the largest study evaluating the correlation between ED and radiation dose to the corpora cavernosa after EBRT for prostate cancer. Until there is clear evidence that sparing the penile bulb or crura will reduce ED after EBRT, we advise to be careful in sparing these structures, especially when this involves reducing treatment margins

  15. External dose measurements for patients receiving therapeutic I-131 for thyroid cancer

    International Nuclear Information System (INIS)

    Molfetas, M.; Kottou, S.

    2002-01-01

    Iodine-131 is a well established and effective treatment, supplementing surgery, in differentiated thyroid carcinoma. Iodine-131 except from its β-emission, that generates a cell-killing effect in a small area, has also a γ-emission irradiating distant tissues and even people who are close enough with the treated patient. The International Commission on Radiation Protection, ICRP has estimated the probability of a radiation-induced fatal cancer for the whole population at 5.0 % per sievert for low doses and at low dose rates and at 1.3 % for serious genetic diseases. For elderly people the probability seems to be 3 to 10 times lower, whereas for children up to the age of 10 years, 2-3 times higher. These findings led the ICRP to recommend new dose limits, lower than the previous ones. The European Union has endorsed the ICRP recommendations and the Council issued two directives, with which the Greek legislation complied recently. The current annual public dose limit is 1 mSv, while in the new Greek legislation the concept of dose constrains (0.5 m Sv in Greece) has also been proposed as a goal to reach whenever possible

  16. External exposure level from natural radiation and population dose in Gansu province

    International Nuclear Information System (INIS)

    Guo Shanxiang; Li Fuzeng; Jiao Yufang

    1985-01-01

    The resultts of measurement of absorbed dose rate in air from natural gamma radiation in Gansu measured with FD-71 scintillation radiometers are reported in this paper. Sketch maps of distribution of absorbed dose rates from natural radiation in this province are also presented. The mean values of absorbed rates in air from terrestrial gamma radiation for outdoors and indoors are 0.7 mGy/a (range 0.32 to 1.11 mGy/a) and 1.02 mGy/a (range 0.73 to 1.4 mGy/a), respectively. The annual effective dose equivalent from terrestrial gamma radiation to population in this province is estimated to be 1,14 mSv

  17. IDACstar: A MCNP Application to Perform Realistic Dose Estimations from Internal or External Contamination of Radiopharmaceuticals.

    Science.gov (United States)

    Ören, Ünal; Hiller, Mauritius; Andersson, M

    2017-04-28

    A Monte Carlo-based stand-alone program, IDACstar (Internal Dose Assessment by Computer), was developed, dedicated to perform radiation dose calculations using complex voxel simulations. To test the program, two irradiation situations were simulated, one hypothetical contamination case with 600 MBq of 99mTc and one extravasation case involving 370 MBq of 18F-FDG. The effective dose was estimated to be 0.042 mSv for the contamination case and 4.5 mSv for the extravasation case. IDACstar has demonstrated that dosimetry results from contamination or extravasation cases can be acquired with great ease. An effective tool for radiation protection applications is provided with IDACstar allowing physicists at nuclear medicine departments to easily quantify the radiation risk of stochastic effects when a radiation accident has occurred. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. The calculation of external gamma-ray doses from airborne and deposited radionuclides in the environmental code NECTAR

    International Nuclear Information System (INIS)

    Corbett, J.O.

    1982-02-01

    A computer program has been developed for the rapid evaluation of external gamma-ray doses from airborne and deposited radionuclide mixtures. Based on a gaussian dispersion model, the program calculates the dose at any position, including points high above ground level or upwind of the source. Meteorological frequency data for wind speed, direction, atmospheric stability and rainfall are fully taken into account. The calculational model assumes that the ground surface is perfectly flat and that gamma-ray paths are entirely in air; the possible errors caused by these and other assumptions are discussed, with suggested correction factors. The program applies various criteria to determine the best approximation or numerical integration method for each target point; execution times (on an IBM 370 machine) thus vary from less than 0.01s to about 0.3s per target point for a single weather category. The program has been incorporated in the environmental release program NECTAR. (author)

  19. Didactic revision of the operative magnitudes system ICRU for the evaluation of the equivalent dose in radiation external fields

    International Nuclear Information System (INIS)

    Alvarez R, J. T.

    2014-10-01

    In this work is presented in a didactic way the operative magnitudes system ICRU, showing as these magnitudes carry out an appropriate estimate of the effective equivalent doses H E and the effective dose. The objective is to present the basic concepts of the dosimetry for radiation external fields with purposes of radiological protection, because the assimilation lack and technological development of this dosimetric magnitudes system has persisted for near 50 years, in terms of practice of the radiological protection in Mexico. Also, this system is an essential part of safety basic standards of the IAEA and ICRP recommendations 26, 60, 74 and 103, as well as of the ICRU 25, 39, 43, 51 and 57. (Author)

  20. The influence of single and fractionated dose external beam irradiation on injury-induced arterial smooth muscle cell proliferation

    International Nuclear Information System (INIS)

    Schaefer, U.; Micke, O.; Dorszewski, A.; Breithardt, G.; Willich, N.

    1997-01-01

    Purpose/Objective: Restenosis after catheter-based revascularization has been demonstrated to be primarily caused by smooth muscle cell proliferation. This study examined the effects of external beam irradiation on neointimal proliferation after external injury to the central artery of the rabbit ear. Materials and Methods: 40 male New Zealand White rabbits were used in this study. Crush lesions were performed on each ear under general anesthesia and bilateral auricular nerve blockade. A single dose of 12 Gy (n=10), 16 Gy (n=10), or 20 Gy (n=10) and a fractionated dose of 4 x 5 Gy (n=10) gamma radiation was delivered to the left or right central artery of the ear 24 hours after injury; the contralateral central artery served as control. All rabbits were sacrificed after twenty-one days and the central arteries of the ear were fixed for morphometric measurements. Results: Mean (± SD) neointimal area was 0.062 ± 0.005 mm 2 (12 Gy), 0.022 ± 0,005 mm 2 (16 Gy), 0,028 ± 0,006 mm 2 and 0.038 mm 2 ± 0,02 mm 2 (4 x 5 Gy) in irradiated arteries compared with 0,081 ± 0,009 mm 2 in the control group. Mean (±SD) luminal area was 0.049 ± 0.004 mm 2 (12 Gy), 0.059 ± 0.002 mm 2 (16 Gy), 0.072 ± 0,006 mm 2 (20 Gy) and 0.048 mm 2 ± 0,018 mm 2 (4 x 5 Gy) in irradiated arteries compared with 0,043 ± 0,008 mm 2 in the control group. The difference in neointimal and luminal area between control and irradiated arteries was significant (p<0.05) only for the 16 and 20 Gy group compared to control. Conclusion: We conclude that in this model, external beam X-ray irradiation was successful in reducing neointimal proliferation after injury of the central artery of the rabbit ear. The optimal dose seems to be a single dose of 16 Gy - 20 Gy. Only a less prominent effect was noted for a fractionated dose of 4 x 5 Gy. Whether this approach can be used successfully to inhibit restenosis in the clinical setting requires further investigation

  1. Effects of activity inhomogeneities in walls on the external gamma doses in rooms

    Energy Technology Data Exchange (ETDEWEB)

    Feher, I; Andrasi, A; Koblinger, L; Zombori, P; Szabo, P P [Hungarian Academy of Sciences, Budapest. Central Research Inst. for Physics

    1984-01-01

    The effects of activity inhomogeneities in the walls of a room on the free-in-air and spherical phantom doses are investigated. Calculations and measurements are carried out in a room where the ratios of the activity concentrations in the upper layer of the ceiling and floor are as large as 20 and 6, for the Ra and Th chains, respectively.

  2. Absorbed dose determination in external beam radiotherapy. An international code of practice for dosimetry based on standards of absorbed dose to water

    International Nuclear Information System (INIS)

    2000-01-01

    The International Atomic Energy Agency published in 1987 an International Code of Practice entitled 'Absorbed Dose Determination in Photon and Electron Beams' (IAEA Technical Reports Series No. 277 (TRS-277)), recommending procedures to obtain the absorbed dose in water from measurements made with an ionization chamber in external beam radiotherapy. A second edition of TRS-277 was published in 1997 updating the dosimetry of photon beams, mainly kilovoltage X rays. Another International Code of Practice for radiotherapy dosimetry entitled 'The Use of Plane-Parallel Ionization Chambers in High Energy Electron and Photon Beams' (IAEA Technical Reports Series No. 381 (TRS-381)) was published in 1997 to further update TRS-277 and complement it with respect to the area of parallel-plate ionization chambers. Both codes have proven extremely valuable for users involved in the dosimetry of the radiation beams used in radiotherapy. In TRS-277 the calibration of the ionization chambers was based on primary standards of air kerma; this procedure was also used in TRS-381, but the new trend of calibrating ionization chambers directly in a water phantom in terms of absorbed dose to water was introduced. The development of primary standards of absorbed dose to water for high energy photon and electron beams, and improvements in radiation dosimetry concepts, offer the possibility of reducing the uncertainty in the dosimetry of radiotherapy beams. The dosimetry of kilovoltage X rays, as well as that of proton and heavy ion beams, interest in which has grown considerably in recent years, can also be based on these standards. Thus a coherent dosimetry system based on standards of absorbed dose to water is possible for practically all radiotherapy beams. Many Primary Standard Dosimetry Laboratories (PSDLs) already provide calibrations in terms of absorbed dose to water at the radiation quality of 60 Co gamma rays. Some laboratories have extended calibrations to high energy photon and

  3. External beam radiotherapy dose response characteristics of 1127 men with prostate cancer treated in the PSA era

    International Nuclear Information System (INIS)

    Pollack, Alan; Smith, Lewis G.; Eschenbach, Andrew C. von

    2000-01-01

    Purpose: To characterize the relationship of radiotherapy dose to prostate cancer patient outcome, with an emphasis on the influence of pretreatment prognostic variables. Methods and Materials: The 1127 Stage T1-T4 prostate cancer patients examined were treated consecutively with definitive external beam radiotherapy at the University of Texas-M.D. Anderson Cancer Center from 1987 to 1997. All had a pretreatment prostate-specific antigen (PSA) level. Treatment failure was defined as two consecutive PSA elevations on follow-up. There were 994 patients treated with a four-field box throughout to 60-70 Gy after a small reduction at 46 Gy and 161 treated with a six-field conformal boost after 46 Gy to 74-78 Gy. No patient received neoadjuvant or adjuvant androgen ablation. Median follow-up was 51.8 months. Results: Patients were divided into three radiotherapy dose groups consisting of ≤67 Gy (n = 500), >67-77 Gy (n = 495), and >77 Gy (n = 132). Relative to other prognostic factors, there were fewer patients treated to the highest dose level with a pretreatment PSA (PSAB) ≤4 or >20 ng/ml, Stage T3/T4 disease, or a Gleason score of 2-6. Actuarial 4-year freedom from biochemical failure (bNED) rates for the entire cohort were 54%, 71%, and 77% (p 67-77 Gy was associated with improved bNED rates for all PSAB (≤10 and >10), stage (T1/T2 and T3/T4), and Gleason score (2-6 and 7-10) subgroups tested. In contrast, the only prognostic group that benefited from raising dose from >67-77 Gy to >77 Gy was patients with a PSAB >10 ng/ml; although trends were noted for Stage T1/T2 and Gleason 2-6 patients. Patients with the combined features of a PSAB >10 ng/ml and Stage T1/T2 disease had 4-year bNED rates of 61% and 93% at the intermediate- and high-dose levels. A strongly significant linear association between dose (60-78 Gy) and 4-year actuarial bNED was demonstrated for patients with these intermediate-risk features. Conclusion: Prostate cancer dose response to external

  4. High Total Ionizing Dose and Temperature Effects on Micro- and Nano-electronic Devices

    International Nuclear Information System (INIS)

    Gaillardin, M.; Martinez, M.; Paillet, P.; Leray, J.L.; Marcandella, C.; Duhamel, O.; Raine, M.; Richard, N.; Girard, S.; Ouerdane, Y.; Boukenter, A.; Goiffon, V.; Magnan, P.; Andrieu, F.; Barraud, S.; Faynot, O.

    2013-06-01

    This paper investigates the vulnerability of several micro- and nano-electronic technologies to a mixed harsh environment including high total ionizing dose at MGy levels and high temperature. Such operating conditions have been revealed recently for several applications like new security systems in existing or future nuclear power plants, fusion experiments, or deep space missions. In this work, the competing effects already reported in literature of ionizing radiations and temperature are characterized in elementary devices made of MOS transistors from several technologies. First, devices are irradiated using a radiation laboratory X-ray source up to MGy dose levels at room temperature. Devices are grounded during irradiation to simulate a circuit which waits for a wake up signal, representing most of the lifetime of an integrated circuit operating in a harsh environment. Devices are then annealed at several temperatures to discuss the post-irradiation behavior and to determine whether an elevated temperature is an issue or not for circuit function in mixed harsh environments. (authors)

  5. Anti-tumor effect of total body irradiation of low doses on WHT/Ht mice

    International Nuclear Information System (INIS)

    Miyamoto, Miyako; Sakamoto, Kiyohiko

    1987-01-01

    The effect of low dose (0.05 - 1.0 Gy) of total body irradiation (TBI) on non-tumor bearing and tumor bearing mice were investigated. Mice received TBI of 0.1 Gy during 6 - 12 hours before tumor cell inoculation demonstrated to need larger number of tumor cells (approximately 2.5 times) for 50 per cent tumor incidence, compared to recipient mice not to receive TBI. On the other hand, in tumor bearing mice given 0.1 Gy of TBI only tumor cell killing effect was not detected, however enhancement of tumor cell killing effect and prolonged growth delay were observed when tumor bearing mice were treated with 0.1 Gy of TBI in combined with local irradiation on tumors, especially cell killing effect was remarkable in dose range over 6 Gy of local exposure. The mechanism of the effect of 0.1 Gy TBI is considered to be host mediated reactions from the other our experimental results. (author)

  6. Total dose radiation effects of pressure sensors fabricated on uni-bond-SOI materials

    International Nuclear Information System (INIS)

    Zhu Shiyang; Huang Yiping; Wang Jin; Li Anzhen; Shen Shaoqun; Bao Minhang

    2001-01-01

    Piezoresistive pressure sensors with a twin-island structure were successfully fabricated using high quality Uni-bond-SOI (On Insulator) materials. Since the piezoresistors were structured by the single crystalline silicon overlayer of the SOI wafer and were totally isolated by the buried SiO 2 , the sensors are radiation-hard. The sensitivity and the linearity of the pressure sensors keep their original values after being irradiated by 60 Co γ-rays up to 2.3 x 10 4 Gy(H 2 O). However, the offset voltage of the sensor has a slight drift, increasing with the radiation dose. The absolute value of the offset voltage deviation depends on the pressure sensor itself. For comparison, corresponding polysilicon pressure sensors were fabricated using the similar process and irradiated at the same condition

  7. Characterization of total ionizing dose damage in COTS pinned photodiode CMOS image sensors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zujun, E-mail: wangzujun@nint.ac.cn; Ma, Wuying; Huang, Shaoyan; Yao, Zhibin; Liu, Minbo; He, Baoping; Sheng, Jiangkun; Xue, Yuan [State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an, Shaanxi 710024 (China); Liu, Jing [School of Materials Science and Engineering, Xiangtan University, Hunan (China)

    2016-03-15

    The characterization of total ionizing dose (TID) damage in COTS pinned photodiode (PPD) CMOS image sensors (CISs) is investigated. The radiation experiments are carried out at a {sup 60}Co γ-ray source. The CISs are produced by 0.18-μm CMOS technology and the pixel architecture is 8T global shutter pixel with correlated double sampling (CDS) based on a 4T PPD front end. The parameters of CISs such as temporal domain, spatial domain, and spectral domain are measured at the CIS test system as the EMVA 1288 standard before and after irradiation. The dark current, random noise, dark signal non-uniformity (DSNU), photo response non-uniformity (PRNU), overall system gain, saturation output, dynamic range (DR), signal to noise ratio (SNR), quantum efficiency (QE), and responsivity versus the TID are reported. The behaviors of the tested CISs show remarkable degradations after radiation. The degradation mechanisms of CISs induced by TID damage are also analyzed.

  8. Total-ionizing-dose effects on isolation oxides in modern CMOS technologies

    International Nuclear Information System (INIS)

    Barnaby, Hugh J.; Mclain, Michael; Esqueda, Ivan Sanchez

    2007-01-01

    This paper presents experimental data on the total dose response of deep sub-micron bulk CMOS devices and integrated circuits. Ionizing radiation experiments on shallow trench isolation (STI) field oxide MOS capacitors (FOXCAP) indicate a characteristic build-up of radiation-induced defects in the dielectric. In this paper, capacitors fabricated with STI, thermal, SIMOX and bipolar base oxides of similar thickness are compared and show the STI oxide to be most susceptible to radiation effects. Experimental data on irradiated shift registers and n-channel MOSFETs are also presented. These data indicate that radiation damage to the STI can increase the off-state current of n-channel devices and the standby current of CMOS integrated circuits

  9. New insights into fully-depleted SOI transistor response during total-dose irradiation

    International Nuclear Information System (INIS)

    Schwank, J.R.; Shaneyfelt, M.R.; Dodd, P.E.; Burns, J.A.; Keast, C.L.; Wyatt, P.W.

    1999-01-01

    In this paper, we present irradiation results on 2-fully depleted processes (HYSOI6, RKSOI) that show SOI (silicon on insulator) device response can be more complicated than originally suggested by others. The major difference between the 2 process versions is that the RKSOI process incorporates special techniques to minimize pre-irradiation parasitic leakage current from trench sidewalls. Transistors were irradiated at room temperature using 10 keV X-ray source. Worst-case bias configuration for total-dose testing fully-depleted SOI transistors was found to be process dependent. It appears that the worst-case bias for HYPOI6 process is the bias that causes the largest increase in sidewall leakage. The RKSOI process shows a different response during irradiation, the transition response appears to be dominated by charge trapping in the buried oxide. These results have implications for hardness assurance testing. (A.C.)

  10. Origins of Total-Dose Response Variability in Linear Bipolar Microcircuits

    International Nuclear Information System (INIS)

    Barnaby, H.J.; Cirba, C.R.; Schrimpf, R.D.; Fleetwood, D.M.; Pease, R.L.; Shaneyfelt, Marty R.; Turflinger, T.; Krieg, J.F.; Maher, M.C.

    2000-01-01

    LM1ll voltage comparators exhibit a wide range of total-dose-induced degradation. Simulations show this variability may be a natural consequence of the low base doping of the substrate PNP (SPNP) input transistors. Low base doping increases the SPNP's collector to base breakdown voltage, current gain, and sensitivity to small fluctuations in the radiation-induced oxide defect densities. The build-up of oxide trapped charge (N ot ) and interface traps (N it ) is shown to be a function of pre-irradiation bakes. Experimental data indicate that, despite its structural similarities to the LM111, irradiated input transistors of the LM124 operational amplifier do not exhibit the same sensitivity to variations in pre-irradiation thermal cycles. Further disparities in LM111 and LM124 responses may result from a difference in the oxide defect build-up in the two part types. Variations in processing, packaging, and circuit effects are suggested as potential explanations

  11. Analysis of surface contributions to external doses in a radioactively contaminated urban environment designed by the EMRAS-2 Urban Areas Working Group

    International Nuclear Information System (INIS)

    Hwang, Won Tae; Jeong, Hae Sun; Jeong, Hyo Joon; Kim, Eun Han; Han, Moon Hee; Kim, In Gyu

    2013-01-01

    Highlights: ► External dose and contribution from radio-activated surface were evaluated for EMRAS-2 Urban Areas Working Group scenarios. ► The external doses showed a distinctive difference with the locations and precipitation. ► The contribution of contaminated surfaces for external dose depends on locations and precipitation. ► These results provide the essential information for decision-making support of countermeasures. - Abstract: The EMRAS-2 Urban Areas Working Group, which is supported by the IAEA, has designed a variety of accidental scenarios to test and improve the capabilities of the models used for an evaluation of radioactive contamination in an urban environment. A variety of models including a Korean model, METRO-K, are used for predictive results on the hypothetical scenarios. This paper describes the predictive results of METRO-K for the hypothetical scenarios designed in the Working Group. The external dose resulting from the air contamination of Co-60 was evaluated, and its contribution was analyzed with time as a function of the location of a receptor and precipitation conditions at the time of the contamination event. As a result, the external doses showed a distinctive difference with the locations to be evaluated and the precipitation conditions. Moreover, the contribution of contaminated surfaces for external doses was strongly dependent on the locations to be evaluated and the precipitation conditions. These results will provide essential information to assist the decision-making of appropriate countermeasures in an emergency situation of a radioactively contaminated urban environment

  12. Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy.

    Science.gov (United States)

    Alabdoaburas, Mohamad M; Mege, Jean-Pierre; Chavaudra, Jean; Bezin, Jérémi Vũ; Veres, Atilla; de Vathaire, Florent; Lefkopoulos, Dimitri; Diallo, Ibrahima

    2015-11-08

    The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off-axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD-700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel-plane ionization chamber measurements. Also, out-of-field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12-15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10 × 10 cm(²) applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10 × 10 cm(²) applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out-of-field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long-term effects.

  13. Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations

    DEFF Research Database (Denmark)

    Knöös, Tommy; Wieslander, Elinore; Cozzi, Luca

    2006-01-01

    to the fields. A Monte Carlo calculated algorithm input data set and a benchmark set for a virtual linear accelerator have been produced which have facilitated the analysis and interpretation of the results. The more sophisticated models in the type b group exhibit changes in both absorbed dose and its...... distribution which are congruent with the simulations performed by Monte Carlo-based virtual accelerator....

  14. Urinary excretion and external radiation dose from patients administered with radiopharmaceuticals

    International Nuclear Information System (INIS)

    Konishi, E.; Abe, K.; Kusama, T.

    1994-01-01

    Patients who have received radiopharmaceuticals become a source of exposure to those near them, such as nursing staff or visiting relatives. In order to provide quantitative information to propose protective measures for carers attending patients administered diagnostic amounts of 99 Tc, 67 Ga or 201 Tl (the most frequently used radiopharmaceuticals) the dose rate at various distances from 84 patients was measured using an ionising chamber, and the radioactivity of these compounds in urine collected from some patients was also measured. (author)

  15. Radon concentration in air and external gamma dose rate. Is there a correlation?

    International Nuclear Information System (INIS)

    Yoshimura, E.M.; Umisedo, N.K.; Marcos Rizzotto; Hugo Velasco; Valladares, D.L.

    2016-01-01

    We checked the existence of correlations between experimentally determined radon concentration in indoor air and gamma dose rate, in different environments: residences, workplaces in subway stations and radiotherapies, and a gold mine. Except for the mine environment, where a linear correlation (r 2 = 0.86) was obtained with statistical significance, we found no correlations between those quantities. Both radiation sources are originated from natural radionuclides, nonetheless the observation of correlations depends on various conditions, as we discuss here. (author)

  16. Defining a dose-response relationship for prostate external beam radiotherapy

    International Nuclear Information System (INIS)

    Trada, Yuvnik; Plank, Ash; Martin, Jarad

    2013-01-01

    We aimed to quantify a relationship between radiotherapy dose and freedom from biochemical failure (FFBF) in low- and intermediate-risk prostate cancer. To reduce confounding we used data with a standardised end–point, mature follow-up, low competing risk of metastatic failure, conventional fractionation and separate reporting for outcomes with hormonal therapy (HT). A systematic review of the literature was carried out. Studies that reported the use of radiotherapy alone in 1.8–2Gy fractions in low- and intermediate-risk prostate cancer were included. The primary end–point was Phoenix definition 5-year FFBF. A logistic regression was used to quantify the dose–response relationship. Data from eight studies with 3037 patients met the inclusion criteria. The data from 810 low-risk patients and 2245 intermediate-risk patients were analysed. A strong association between radiotherapy dose and FFBF was found in low- and intermediate-risk patients managed with radiotherapy alone. In low-risk patients not treated with HT the dose required to achieve 50% biochemical tumour control (TCD 50 ) is 52.0 Gy and the slope of the dose–response curve at TCD 50 (γ 50 ) is 2.1%/Gy. At 78Gy this represented a FFBF of 90.3%. In intermediate-risk patients not treated with HT the TCD 50 is 64.7Gy and γ 50 is 3.2%/Gy. At 78 Gy this translated into a FFBF of 84.3%. HT had a small effect for low-risk patients and an inconsistent effect for intermediate-risk men. A strong association was found between radiation dose and biochemical outcome in both low- and intermediate-risk patients. Standardised reporting of results from future studies will make future analyses more robust.

  17. Clinical study on the adriamycin induced cardiomyopathy using the cardiac magnetic resonance imaging. Total dose and cardiac dysfunction

    International Nuclear Information System (INIS)

    Yamaguchi, Kyoko; Teraoka, Kunihiko; Hirano, Masaharu

    2001-01-01

    We studied cardiac functional disorders caused by Adoriamycin using gadolinium (Gd) contrast cine MRI. Forty-eight patients were given ACT (31 men and 17 women; mean age, 52±15 years). First, the relationship between dose and the left ventricular volume, cardiac function, left ventricular cardiac mass and localized wall motion were examined in all patients. Patients given a total dose of 300 mg/m 2 or higher were assigned to the high dose group and those given doses under 300 mg/m 2 to the low dose group. The same parameters were studied in both groups and compared. A 1.5-Tesla superconductive MRI was used for all studies. Cine images of the long and short axes at the papillary muscle level were obtained by ECG R-wave synchronized Gd contrast cine MRI. Left ventricular volume and cardiac function were analyzed using the long-axis cine images and the wall thickness in diastole and systole was measured at each site using the short-axis cine images. The percentage of wall thickness was calculated at each site. The mean ACT dose was 273.3±218.2 mg/m 2 . In all patients the total dose directly correlated with ESVI and inversely correlated with the ejection fraction (EF). In the high dose group, the total dose and EF were inversely correlated, but no significant differences were observed in the low dose group. In the high dose group, the ESVI was significantly greater and the SVI and EF were more significantly reduced than in the low dose group. In the high dose group, the thickness of the anterior, lateral and posterior walls, excluding the septum, was significantly lower than in the low dose group. However, changes in wall thickness were not significantly different between the groups. Gd contrast cine MRI was useful in examining cardiac functional disorders caused by anthracyclines. The total dose of anthracycline correlated directly with the ESVI, and inversely with the EF. A total dose of 300 mg/m 2 appeared to be the borderline dose beyond which there were

  18. Clinical study on the adriamycin induced cardiomyopathy using the cardiac magnetic resonance imaging. Total dose and cardiac dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Kyoko; Teraoka, Kunihiko; Hirano, Masaharu [Tokyo Medical Coll. (Japan)

    2001-05-01

    We studied cardiac functional disorders caused by Adoriamycin using gadolinium (Gd) contrast cine MRI. Forty-eight patients were given ACT (31 men and 17 women; mean age, 52{+-}15 years). First, the relationship between dose and the left ventricular volume, cardiac function, left ventricular cardiac mass and localized wall motion were examined in all patients. Patients given a total dose of 300 mg/m{sup 2} or higher were assigned to the high dose group and those given doses under 300 mg/m{sup 2} to the low dose group. The same parameters were studied in both groups and compared. A 1.5-Tesla superconductive MRI was used for all studies. Cine images of the long and short axes at the papillary muscle level were obtained by ECG R-wave synchronized Gd contrast cine MRI. Left ventricular volume and cardiac function were analyzed using the long-axis cine images and the wall thickness in diastole and systole was measured at each site using the short-axis cine images. The percentage of wall thickness was calculated at each site. The mean ACT dose was 273.3{+-}218.2 mg/m{sup 2}. In all patients the total dose directly correlated with ESVI and inversely correlated with the ejection fraction (EF). In the high dose group, the total dose and EF were inversely correlated, but no significant differences were observed in the low dose group. In the high dose group, the ESVI was significantly greater and the SVI and EF were more significantly reduced than in the low dose group. In the high dose group, the thickness of the anterior, lateral and posterior walls, excluding the septum, was significantly lower than in the low dose group. However, changes in wall thickness were not significantly different between the groups. Gd contrast cine MRI was useful in examining cardiac functional disorders caused by anthracyclines. The total dose of anthracycline correlated directly with the ESVI, and inversely with the EF. A total dose of 300 mg/m{sup 2} appeared to be the borderline dose beyond

  19. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  20. The carcinogenic risk of high dose total body irradiation in non-human primates

    International Nuclear Information System (INIS)

    Broerse, J.J.; Bartstra, R.W.; Bekkum, D.W. van; Hage, M.H. van der; Zurcher, C.; Zwieten, M.J. van; Hollander, C.F.

    2000-01-01

    High dose total body irradiation (TBI) in combination with chemotherapy, followed by rescue with bone marrow transplantation (BMT), is increasingly used for the treatment of haematological malignancies. With the increasing success of this treatment and its current introduction for treating refractory autoimmune diseases the risk of radiation carcinogenesis is of growing concern. Studies on turnout induction in non-human primates are of relevance in this context since the response of this species to radiation does not differ much from that in man. Since the early sixties, studies have been performed on acute effects in Rhesus monkeys and the protective action of bone marrow transplantation after irradiation with X-rays (average total body dose 6.8 Gy) and fission neutrons (average dose 3.4 Gy). Of those monkeys, which were irradiated and reconstituted with autologous bone marrow, 20 animals in the X-irradiated group and nine animals in the neutron group survived more than 3 years. A group of 21 non-irradiated Rhesus monkeys of a comparable age distribution served as controls. All animals were regularly screened for the occurrence of neoplasms. Complete necropsies were performed after natural death or euthanasia. At post-irradiation intervals of 4-21 years an appreciable number of tumours was observed. In the neutron irradiated group eight out of nine animals died with one or more malignant tumours. In the X-irradiated group this fraction was 10 out of 20. The tumours in the control group, in seven out of the 21 animals, appeared at much older a-e compared with those in the irradiated cohorts. The histogenesis of the tumours was diverse with a preponderance of renal carcinoma, sarcomas among which osteosarcormas, and malignant glomus tumours in the irradiated groups. When corrected for competing risks, the carcinogenic risk of TBI in the Rhesus monkeys is similar to that derived from the studies of the Japanese atomic bomb survivors. The increase of the risk by a

  1. Influence of radioprotectors on total body weight evolution and on oxygen consumption in lethal dose irradiated animals. (Preliminary study)

    International Nuclear Information System (INIS)

    Fatome, M.; Martine, G.; Bargy, E.; Andrieu, L.

    Comparison of total body weight evolution and oxygen consumption in lethal dose irradiated animals, protected by various well known radioprotective substances, isolated or in mixture, with evolution and consumption of non protected animals irradiated at the same dose and with these of check animals [fr

  2. Development of a external exposure computational model for studying of input dose in skin for radiographs of thorax and vertebral column

    International Nuclear Information System (INIS)

    Muniz, Bianca C.; Menezes, Claudio J.M.; Vieira, Jose W.

    2014-01-01

    The dosimetric measurements do not always happen directly in the human body. Therefore, these assessments can be performed using anthropomorphic models (phantoms) evidencing models computational exposure (MCE) using techniques of Monte Carlo Method for virtual simulations. These processing techniques coupled with more powerful and affordable computers make the Monte Carlo method one of the tools most used worldwide in radiation transport area. In this work, the Monte Carlo EGS4 program was used to develop a computer model of external exposure to study the entrance skin dose for chest and column X-radiography and, aiming to optimize these practices by reducing doses to patients, professionals involved and the general public. The results obtained experimentally with the electrometer Radcal, model 9015, associated with the ionization chamber for radiology model 10X5-6, showed that the proposed computational model can be used in quality assurance programs in radiodiagnostic, evaluating the entrance skin dose when varying parameters of the radiation beam such as kilo voltage peak (kVp), current-time product (mAs), total filtration and distance surface source (DFS), optimizing the practices in radiodiagnostic and meeting the current regulation

  3. Updated results of high-dose rate brachytherapy and external beam radiotherapy for locally and locally advanced prostate cancer using the RTOG-ASTRO phoenix definition

    Directory of Open Access Journals (Sweden)

    Antonio C. Pellizzon

    2008-06-01

    Full Text Available PURPOSE: To evaluate the prognostic factors for patients with local or locally advanced prostate cancer treated with external beam radiotherapy (RT and high dose rate brachytherapy (HDR according to the RTOG-ASTRO Phoenix Consensus Conference. MATERIALS AND METHODS: The charts of 209 patients treated between 1997 and 2005 with localized RT and HDR as a boost at the Department of Radiation Oncology, AC Camargo Hospital, Sao Paulo, Brazil were reviewed. Clinical and treatment parameters i.e.: patient's age, Gleason score, clinical stage, initial PSA (iPSA, risk group (RG for biochemical failure, doses of RT and HDR were evaluated. Median age and median follow-up time were 68 and 5.3 years, respectively. Median RT and HDR doses were 45 Gy and 20 Gy. RESULTS: Disease specific survival (DSS at 3.3 year was 94.2%. Regarding RG, for the LR (low risk, IR (intermediate risk and HR (high risk, the DSS rates at 3.3 years were 91.5%, 90.2% and 88.5%, respectively. On univariate analysis prognostic factors related to DSS were RG (p = 0.040, Gleason score ≤ 6 ng/mL (p = 0.002, total dose of HDR ≥ 20 Gy (p < 0.001 On multivariate analysis the only statistical significant predictive factor for biochemical control (bNED was the RG, p < 0.001 (CI - 1.147-3.561. CONCLUSIONS: Although the radiation dose administered to the prostate is an important factor related to bNED, this could not be established with statistical significance in this group of patients. To date , in our own experience, HDR associated to RT could be considered a successful approach in the treatment of prostate cancer.

  4. Fractionated total body irradiation and autologous bone marrow transplantation in dogs: Hemopoietic recovery after various marrow cell doses

    International Nuclear Information System (INIS)

    Bodenburger, U.; Kolb, H.J.; Thierfelder, S.; Netzel, B.; Schaeffer, E.; Kolb, H.

    1980-01-01

    Hemopoietic recovery was studied in dogs given 2400 R fractionated total body irradiation within one week and graded doses of cryopreserved autologous bone marrow. Complete hemopoietic recovery including histology was observed after this dose and sufficient doses of marrow cells. Doses of more than 5.5 x 10 7 mononuclear marrow cells/kg body weight were sufficient for complete recovery in all dogs, 1.5 to 5.5 x 10 7 cells/kg were effective in some of the dogs and less than 1.5 x 10 7 cells/kg were insufficient for complete recovery. Similarly, more than 30000 CFUsub(c)/kg body weight were required for hemopoietic recovery. The optimal marrow cell dose which has been defined as the minimal dose required for the earliest possible recovery of leukocyte and platelet counts was 7-8 x 10 7 mononuclear marrow cells/kg body weight. It has been concluded that fractionated total body irradiation with 2400 R dose not require greater doses of marrow cells for hemopoietic reconstitution than lower single doses and that the hemopoietic microenvironment is not persistently disturbed after this dose. (author)

  5. In vivo dosimetry with semiconducting diodes for dose verification in total-body irradiation. A 10-year experience

    International Nuclear Information System (INIS)

    Ramm, U.; Licher, J.; Moog, J.; Scherf, C.; Kara, E.; Boettcher, H.D.; Roedel, C.; Mose, S.

    2008-01-01

    Background and purpose: for total-body irradiation (TBI) using the translation method, dose distribution cannot be computed with computer-assisted three-dimensional planning systems. Therefore, dose distribution has to be primarily estimated based on CT scans (beam-zone method) which is followed by in vivo measurements to ascertain a homogeneous dose delivery. The aim of this study was to clinically establish semiconductor probes as a simple and fast method to obtain an online verification of the dose at relevant points. Patients and methods: in 110 consecutively irradiated TBI patients (12.6 Gy, 2 x 1.8 Gy/day), six semiconductor probes were attached to the body surface at dose-relevant points (eye/head, neck, lung, navel). The mid-body point of the abdomen was defined as dose reference point. The speed of translation was optimized to definitively reach the prescribed dose in this point. Based on the entrance and exit doses, the mid-body doses at the other points were computed. The dose homogeneity in the entire target volume was determined comparing all measured data with the dose at the reference point. Results: after calibration of the semiconductor probes under treatment conditions the dose in selected points and the dose homogeneity in the target volume could be quantitatively specified. In the TBI patients, conformity of calculated and measured doses in the given points was achieved with small deviations of adequate accuracy. The data of 80% of the patients are within an uncertainty of ± 5%. Conclusion: during TBI using the translation method, dose distribution and dose homogeneity can be easily controlled in selected points by means of semiconductor probes. Semiconductor probes are recommended for further use in the physical evaluation of TBI. (orig.)

  6. Studies on external gamma dose rates in air around Hassan city, Karnataka

    International Nuclear Information System (INIS)

    Shashikumar, T.S.; Gowda, Shivalinge; Chandrashekar; Shivakumar, B.C.

    2017-01-01

    Gamma-ray dose rates in air have been measured in the environment of Hassan City. The measurements were done from 15 locations in and around Hassan city at 1m above from the ground surface using a light weight portable radiation survey meter (Scintillometer) which is suited for radiometric, and environmental surveys. The meter reading fluctuates around a mean value and is proportional to the count rate detected by the unit. This is because of the random nature of radioactivity. The detailed results of the study will be presented. (author)

  7. Does prostate brachytherapy treat the seminal vesicles? A dose-volume histogram analysis of seminal vesicles in patients undergoing combined PD-103 prostate implantation and external beam irradiation

    International Nuclear Information System (INIS)

    Stock, Richard G.; Lo, Yeh-Chi; Gaildon, Mohamoud; Stone, Nelson N.

    1999-01-01

    Purpose: Combined brachytherapy of the prostate and external beam irradiation (EBRT) of the prostate and seminal vesicles (SV) is becoming a popular treatment for high-risk prostate cancer. Dose-volume histogram (DVH) analysis of the SV in patients undergoing this treatment was performed to determine the dose distribution to the SV and the adequacy of this treatment in patients with potential SV involvement. Methods and Materials: Twenty-five consecutive patients were treated with a Pd-103 implant of the prostate alone and 45 Gy of EBRT to the prostate and SV. Attempts were not made to implant the SV but seeds were routinely placed at the junction of the prostate and SV. All patients underwent CT-based post implant dosimetric analysis 1 month after implantation. As part of this analysis, DVH were generated for the prostate and total SV volume (SVT). In addition, the SV was divided into 6-mm-thick volumes identified as SV1, SV2, SV3, SV4, and SV5 starting from the junction of the prostate and SV and extending distally. DVH were also generated for these structures. Delivered dose was defined as the D90 (dose delivered to 90% of the organ on DVH). Results: The median volumes in cc of the prostate, SVT, SV1, SV2, SV3, SV4, and SV5 were 34.33, 9.75, 2.7, 3.48, 2.92, 3.18, and 1.96 respectively. The SVT contained from 0-9 seeds (median 2). There was little dose delivered to the SVT and SV volumes from the implanted prostate. The median D90 values for the prostate, SVT, SV1, SV2, SV3, SV4, and SV5 were 8615 cGy, 675 cGy, 3100 cGy, 1329 cGy, 553 cGy, 246 cGy, and 67 cGy, respectively. The dose delivered to the prostate covered small percentages of SV. The percents of SV volumes covered by the prostate D90 were 11, 35, 3.3, 0, 0, and 0 for SVT, SV1, SV2, SV3, SV4, and SV5, respectively. Conclusions: DVH analysis of the SV reveals that dose generated from an implanted prostate contributes little to the SV. Those patients at high risk for SV involvement may be under treated

  8. Randomized controlled trial on postoperative pulmonary humidification after total laryngectomy: external humidifier versus heat and moisture exchanger.

    Science.gov (United States)

    Mérol, Jean-Claude; Charpiot, Anne; Langagne, Thibault; Hémar, Patrick; Ackerstaff, Annemieke H; Hilgers, Frans J M

    2012-02-01

    Assessment of immediate postoperative airway humidification after total laryngectomy (TLE), comparing the use of an external humidifier (EH) with humidification through a heat and moisture exchanger (HME). Randomized controlled trial (RCT). Fifty-three patients were randomized into the standard (control) EH (N = 26) or the experimental HME arm (N = 27). Compliance, pulmonary and sleeping problems, patients' and nursing staff satisfaction, nursing time, and cost-effectiveness were assessed with trial-specific structured questionnaires and tally sheets. In the EH arm data were available for all patients, whereas in the HME arm data were incomplete for four patients. The 24/7 compliance rate in the EH arm was 12% and in the HME arm 87% (77% if the four nonevaluable patients are considered noncompliant). Compliance and patients' satisfaction were significantly better, and the number of coughing episodes, mucus expectoration for clearing the trachea, and sleeping disturbances were significantly less in the HME arm (P humidification by means of an HME over the use of an EH after TLE. This study therefore underlines that HMEs presently can be considered the better option for early postoperative airway humidification after TLE. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  9. Synergistic effects of total ionizing dose on single event upset sensitivity in static random access memory under proton irradiation

    International Nuclear Information System (INIS)

    Xiao Yao; Guo Hong-Xia; Zhang Feng-Qi; Zhao Wen; Wang Yan-Ping; Zhang Ke-Ying; Ding Li-Li; Luo Yin-Hong; Wang Yuan-Ming; Fan Xue

    2014-01-01

    Synergistic effects of the total ionizing dose (TID) on the single event upset (SEU) sensitivity in static random access memories (SRAMs) were studied by using protons. The total dose was cumulated with high flux protons during the TID exposure, and the SEU cross section was tested with low flux protons at several cumulated dose steps. Because of the radiation-induced off-state leakage current increase of the CMOS transistors, the noise margin became asymmetric and the memory imprint effect was observed. (interdisciplinary physics and related areas of science and technology)

  10. Total dose and dose-rate effects on start-up current in anti-fuse FPGA

    International Nuclear Information System (INIS)

    Wang, J.; Wong, W.; McCollum, J.; Cronquist, B.; Katz, R.; Kleyner, I.; Kleyner, F.

    1999-01-01

    Radiation enhanced start-up current (RESC) in an anti-fuse FPGA, A1280A, is thoroughly investigated and a comprehensive transistor-level mechanism is proposed. Low dose-rate testing, appropriate for civilian space applications, and annealing at room temperature shows RESC to be negligible for the lot of parts tested with a fixed power supply slew rate. (authors)

  11. Dose-response characteristics of low- and intermediate-risk prostate cancer treated with external beam radiotherapy

    International Nuclear Information System (INIS)

    Cheung, Rex; Tucker, Susan L.; Lee, Andrew K.; Crevoisier, Renaud de; Dong Lei; Kamat, Ashish; Pisters, Louis; Kuban, Deborah

    2005-01-01

    Purpose: In this era of dose escalation, the benefit of higher radiation doses for low-risk prostate cancer remains controversial. For intermediate-risk patients, the data suggest a benefit from higher doses. However, the quantitative characterization of the benefit for these patients is scarce. We investigated the radiation dose-response relation of tumor control probability in low-risk and intermediate-risk prostate cancer patients treated with radiotherapy alone. We also investigated the differences in the dose-response characteristics using the American Society for Therapeutic Radiology and Oncology (ASTRO) definition vs. an alternative biochemical failure definition. Methods and materials: This study included 235 low-risk and 387 intermediate-risk prostate cancer patients treated with external beam radiotherapy without hormonal treatment between 1987 and 1998. The low-risk patients had 1992 American Joint Committee on Cancer Stage T2a or less disease as determined by digital rectal examination, prostate-specific antigen (PSA) levels of ≤10 ng/mL, and biopsy Gleason scores of ≤6. The intermediate-risk patients had one or more of the following: Stage T2b-c, PSA level of ≤20 ng/mL but >10 ng/mL, and/or Gleason score of 7, without any of the following high-risk features: Stage T3 or greater, PSA >20 ng/mL, or Gleason score ≥8. The logistic models were fitted to the data at varying points after treatment, and the dose-response parameters were estimated. We used two biochemical failure definitions. The ASTRO PSA failure was defined as three consecutive PSA rises, with the time to failure backdated to the mid-point between the nadir and the first rise. The second biochemical failure definition used was a PSA rise of ≥2 ng/mL above the current PSA nadir (CN + 2). The failure date was defined as the time at which the event occurred. Local, nodal, and distant relapses and the use of salvage hormonal therapy were also failures. Results: On the basis of the

  12. Application of estimating effective dose from external radiation using two dosimeters during maintenance periods at KNPPS

    International Nuclear Information System (INIS)

    Kim, Hee Geun; Kong, Tae Young

    2008-01-01

    The application of a two-dosimeter and its algorithm and a test of its use in an inhomogeneous high radiation field are described. The goal was to develop an improved method for estimating the effective dose during maintenance periods at Korean nuclear power plants (NPPs). The use of the method in domestic and international NPPs including USA, Canada and Japan was also investigated. The algorithms used by the Canadian Ontario Power Generation (OPG) and American ANSI HPS N13.41, Lakshmanan, NCRP, EPRI and Texas A and M University were extensively analyzed as two-dosimeter algorithms. The possibility of their application to NPPs was evaluated using data for each algorithm from two-dosimeter results for an inhomogeneous high radiation field during maintenance periods at Korean NPPs. (author)

  13. External beam radiotherapy alone or combined with high-dose-rate intracavitary irradiation in the treatment of cancer of the esophagus

    International Nuclear Information System (INIS)

    Hishikawa, Y.; Taniguchi, M.; Kamikonya, N.; Tanaka, S.; Miura, T.

    1988-01-01

    Autopsy findings of 35 patients, treated with radiotherapy for an esophageal carcinoma, were reviewed. A residual tumor was seen at autopsy in 7 of 16 patients treated with high-dose-rate intracavitary irradiation following external irradiation, in 13 of 14 patients treated with external irradiation of 50 Gy or more, and in all 5 patients treated with external irradiation of less than 50 Gy. Incidence on lymph node metastasis, at autopsy, did not diifer between the combined radiotherapy group and the external irradiation groups. However, it correlated with disease stage. It was observed in 11 of 17 patients with Stage 1 and Stage 2 disease, compared to 17 of 18 patients with Stage 3 and Stage 4 disease. Distant organ metastasis, at autopsy, also did not differ between the combined radiotherapy group and the external irradiation groups, and was also correlated with disease stage. It was found in 8 of 17 patients with Stage 1 and Stage 2 disease, compared to all 18 patients with Stage 3 and Stage 4 disease. Mean survival was different between the patients treated by high-dose-rate intracavitary irradiation following external irradiation and those treated by external irradiation alone; 11.3 months in the 16 patients treated with combined therapy, as compared to 6.9 months in the 14 patients who received external irradiation of 50 Gy or more, and 3.6 months in the 5 patients who received external irradiation of less than 50 Gy. 6 refs.; 5 tabs

  14. Estimation of dose from exposure to external radiation in the environment

    International Nuclear Information System (INIS)

    Abe, Siro; Fujitaka, Kazunobu

    1978-01-01

    Meteorological factors which influence the external radiation were analysed. Attention was paid to the relationship between the concentration of the radioactive aerosol and the outdoor radiation level. Twelve kinds of data were obtained at Kumatori Site of Kyoto University. The mean diurnal variation and annual variation of each factors were obtained from the data of 25 months periods from August 1974 to August 1976. Outstanding was the result that the outdoor gamma radiation varied just slightly in spite of the large variation of the airborne activities and others. It implies that the individual effect due to the factor would compensate and cancel each other. Otherwise the major contribution on the variation might distribute at random with respect to time. Contrary to the apparent independence of the outdoor gamma radiation level of the airborne activity, however, the partial correlation coefficient between them was not negligibly small. Analysis of each time series of individual data has revealed that the rainfall has the largest influence on the variation of the outdoor gamma radiation level particularly in its initial period. Airborne activity was also revealed to have a strong connection with the atmospheric stability and the wind velocity though it depends on the rainfall just a little. The atmospheric stability could be expressed by the vertical gradient of the atmospheric temperature which is strongest at the ''inversion''. However problem remains as to the nature of the wind. Which of the atmospheric turbulence and the prevailing wind corresponds to the wind here will have to be analysed referring to the large scale weather charts. Regression analysis showed that the atmospheric temperature was the essential cause of the variation of the radiation level. (author)

  15. [Single intravenous tranexamic acid dose to reduce blood loss in primary total knee replacement].

    Science.gov (United States)

    Sanz-Reig, J; Parra Ruiz, B; Ferrández Martínez, J; Martínez López, J F

    2016-01-01

    To evaluate the effectiveness and safety of a single intravenous dose of tranexamic acid in order to reduce blood loss in total knee replacement. Prospective observational study of the administration of tranexamic acid in patients undergoing primary total knee arthroplasty from November 2013 to February 2015, in which an autologous blood recovery system was used. The study included 98 patients, distributed into two groups of 49 patients according to whether or not they received intravenous tranexamic acid. The primary endpoint was the number of patients requiring autologous transfusion from the recovery system autologous blood recovery system. No drop-outs were recorded during follow-up. There were no significant differences between groups as regards the preoperative and hospital variables. The mean preoperative haemoglobin and haematocrit at 24 and 48 hours postoperatively were similar in both groups. The average volume of bleeding in the autologous blood recovery system and estimated average blood loss was lower in patients who had been administered tranexamic acid, with significant differences. No patients in the group that was administered tranexamic acid required blood autotransfusion. The transfusion rate was zero in the two groups. No adverse events related to the administration of tranexamic acid were recorded. Intravenous administration of tranexamic acid, according to the described protocol, has presented a non-autotransfusion or allo-transfusion rate of 100%, with no increased incidence of thrombotic events. Thus, its use in this group of patients is recommended. The indication should be individualized, its use justified in the patient medical records, and informed consent is mandatory. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  16. Internal and external generalizability of temporal dose-response relationships for xerostomia following IMRT for head and neck cancer.

    Science.gov (United States)

    Thor, Maria; Owosho, Adepitan A; Clark, Haley D; Oh, Jung Hun; Riaz, Nadeem; Hovan, Allan; Tsai, Jillian; Thomas, Steven D; Yom, Sae Hee K; Wu, Jonn S; Huryn, Joseph M; Moiseenko, Vitali; Lee, Nancy Y; Estilo, Cherry L; Deasy, Joseph O

    2017-02-01

    To study internal and external generalizability of temporal dose-response relationships for xerostomia after intensity-modulated radiotherapy (IMRT) for head and neck cancer, and to investigate potential amendments of the QUANTEC guidelines. Objective xerostomia was assessed in 121 patients (n Cohort1 =55; n Cohort2 =66) treated to 70Gy@2Gy in 2006-2015. Univariate and multivariate analyses (UVA, MVA with 1000 bootstrap populations) were conducted in Cohort1, and generalizability of the best-performing MVA model was investigated in Cohort2 (performance: AUC, p-values, and Hosmer-Lemeshow p-values (p HL )). Ultimately and for clinical guidance, minimum mean dose thresholds to the contralateral and the ipsilateral parotid glands (Dmean contra , Dmean ipsi ) were estimated from the generated dose-response curves. The observed xerostomia rate was 38%/47% (3months) and 19%/23% (11-12months) in Cohort1/Cohort2. Risk of xerostomia at 3months increased for higher Dmean contra and Dmean ipsi (Cohort1: 0.17·Dmean contra +0.11·Dmean ipsi -8.13; AUC=0.90±0.05; p=0.0002±0.002; p HL =0.22±0.23; Cohort2: AUC=0.81; pxerostomia following IMRT. Our results also suggest decreasing Dmean contra to below 20Gy, while keeping Dmean ipsi to around 25Gy. Long-term xerostomia was less frequent, and no dose-response relationship was established for this follow-up time. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Effect of high-dose preoperative methylprednisolone on recovery after total hip arthroplasty

    DEFF Research Database (Denmark)

    Lunn, T H; Andersen, Lasse Østergaard; Kristensen, B B

    2013-01-01

    (IQR) (95% CI), MP vs placebo]: 23.5 (23.3-23.7) (17.8-43.8) vs 23.5 (23.0-23.8) (20.0-46.8) h, the mean difference (95% CI) being -1.3 (-4.7 to 2.2) h, P=0.65. Overall pain for the first 24 h after surgery was significantly reduced in the MP vs the placebo group (PMP 125 mg i.v. before surgery added......BACKGROUND: /st>High-dose glucocorticoid may reduce postsurgical pain and improve recovery. We hypothesized that 125 mg methylprednisolone (MP) would reduce time to meet functional discharge criteria after total hip arthroplasty (THA). METHODS: /st>Forty-eight patients undergoing unilateral THA...... under spinal anaesthesia were consecutively included in this randomized, double-blind, placebo-controlled trial receiving preoperative i.v. MP or saline. All patients received a standardized, multimodal analgesic regime with paracetamol, celecoxib, and gabapentin. The primary outcome was time to meet...

  18. Total Ionizing Dose effects in 130-nm commercial CMOS technologies for HEP experiments

    CERN Document Server

    Gonella, L; Silvestri, M; Gerardin, S; Pantano, D; Re, V; Manghisoni, M; Ratti, L; Ranieri, A

    2007-01-01

    The impact of foundry-to-foundry variability and bias conditions during irradiation on the Total Ionizing Dose (TID) response of commercial 130-nm CMOS technologies have been investigated for applications in High Energy Physics (HEP) experiments. n- and p-channel MOSFETs from three different manufacturers have been irradiated with X-rays up to more than 100 Mrad (SiO2). Even though the effects of TID are qualitatively similar, the amount of degradation is shown to vary considerably from foundry to foundry, probably depending on the processing of the STI oxide and/or doping profile in the substrate. The bias during irradiation showed to have a strong impact as well on the TID response, proving that exposure at worst case bias conditions largely overestimates the degradation a device may experience during its lifetime. Overall, our results increase the confidence that 130-nm CMOS technologies can be used in future HEP experiments even without Hardness-By-Design solutions, provided that constant monitoring of th...

  19. External beam radiotherapy boosted with high dose rate brachytherapy in completely resected uterine sarcomas. Is this a treatment option?

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis; Novaes, Paulo Eduardo Ribeiro dos Santos; Maia, Maria Aparecida Conte; Ferrigno, Robson; Fogarolli, Ricardo; Salvajoli, Joao Vitor [Hospital de Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Oncologia de Radiacao]. E-mail: pellizzon@aol.com

    2005-04-15

    Uterine sarcoma (US) is a relative rare tumor, which accounts for only about 3-5% of all uterine cancers. Aggressive cytoreductive surgery at the time of the initial diagnosis with maximum tumor debulking may lead to a prolonged survival or cure. Objective: to identify and review the role of adjuvant external beam radiation therapy (EBRT) associated with high dose rate brachytherapy (HDRB) in the management of patients presenting US with complete resection. Material and methods: this study is a retrospective analysis of 23 patients with US treated from 10/92 to 03/03, with surgery, external beam radiation therapy (EBRT) and high dose rate brachytherapy (HDRB). The inclusion criteria for study participation included: histologically proven and graded US, completely resection of tumor, Karnofsky status 60-100, absence of significant infection, and recovery from recent surgery. Results: The median age of patients was 62 years (range 39-84); ten-year actuarial disease-free and overall survivals were 42.2% and 63.4%, respectively. On univariate analysis, predictive factors for disease-free survival (DFS) were age at initial presentation (p=0.0268), parity (p=0.0441), tumor grade (p= 0.0095), cervical or vaginal invasion (p=0.0014) and node dissection at time of surgery (p= 0.0471). On multivariate analysis, the only predictive factor was cervical or vaginal invasion (p= 0.048), hazard ratio of 4.7. Conclusion: it is quite likely that neither radiotherapy nor chemotherapy alone will appreciably improve survival in US. If radiation therapy provides better locoregional tumor control, hematogenous metastases will assume an even greater proportion of treatment failures. Unfortunately, our small and heterogeneous group analyzed precludes any definitive conclusions about the impact of HDRB associated to EBRT radiation therapy on recurrence or survival. (author)

  20. External beam radiotherapy boosted with high dose rate brachytherapy in completely resected uterine sarcomas. Is this a treatment option?

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Novaes, Paulo Eduardo Ribeiro dos Santos; Maia, Maria Aparecida Conte; Ferrigno, Robson; Fogarolli, Ricardo; Salvajoli, Joao Vitor

    2005-01-01

    Uterine sarcoma (US) is a relative rare tumor, which accounts for only about 3-5% of all uterine cancers. Aggressive cytoreductive surgery at the time of the initial diagnosis with maximum tumor debulking may lead to a prolonged survival or cure. Objective: to identify and review the role of adjuvant external beam radiation therapy (EBRT) associated with high dose rate brachytherapy (HDRB) in the management of patients presenting US with complete resection. Material and methods: this study is a retrospective analysis of 23 patients with US treated from 10/92 to 03/03, with surgery, external beam radiation therapy (EBRT) and high dose rate brachytherapy (HDRB). The inclusion criteria for study participation included: histologically proven and graded US, completely resection of tumor, Karnofsky status 60-100, absence of significant infection, and recovery from recent surgery. Results: The median age of patients was 62 years (range 39-84); ten-year actuarial disease-free and overall survivals were 42.2% and 63.4%, respectively. On univariate analysis, predictive factors for disease-free survival (DFS) were age at initial presentation (p=0.0268), parity (p=0.0441), tumor grade (p= 0.0095), cervical or vaginal invasion (p=0.0014) and node dissection at time of surgery (p= 0.0471). On multivariate analysis, the only predictive factor was cervical or vaginal invasion (p= 0.048), hazard ratio of 4.7. Conclusion: it is quite likely that neither radiotherapy nor chemotherapy alone will appreciably improve survival in US. If radiation therapy provides better locoregional tumor control, hematogenous metastases will assume an even greater proportion of treatment failures. Unfortunately, our small and heterogeneous group analyzed precludes any definitive conclusions about the impact of HDRB associated to EBRT radiation therapy on recurrence or survival. (author)

  1. Optimization of total arc degree for stereotactic radiotherapy by using integral biologically effective dose and irradiated volume

    International Nuclear Information System (INIS)

    Lim, Do Hoon; Kim, Dae Yong; Lee, Myung Za; Chun, Ha Chung

    2001-01-01

    To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. With Xknife-3 planning system and 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, 100 deg, 200 deg, 300 deg, 400 deg, 500 deg, 600 deg, of total arc degrees, and 30 deg or 45 deg of arc intervals were used. After the completion of planning, the plans were compared each other using V 50 (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. At 30 deg of arc interval, the values of V 50 had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval, up to 400 deg of total arc degree, the values of V 50 decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. At 30 deg of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with 50 and 60 mm of collimator diameters, up to 400 deg of total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. In the stereotactic radiotherapy planning for brain lesions, planning with 400 deg of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of 500 deg and 600 deg of total arc degrees make the increase of V 50 and integral biologically effective dose, Therefore stereotactic radiotherapy planning using 400 deg of total arc degree can increase the therapeutic ratio and produce the effective outcome

  2. Effects of internal and external scatter on the build-up characteristics of Monte Carlo calculated absorbed dose for electron irradiation

    International Nuclear Information System (INIS)

    Lin, H.; Wu, DS.; Wu, AD.

    2005-01-01

    The effects of internal and external scatter on surface, build-up and depth dose characteristics simulated by Monte Carlo code EGSnrc for varying field size and SSD for a 10 MeV monoenergetic electron beam with and without an accelerator model are extensively studied in this paper. In particular, sub-millimetre surface PDD was investigated. The percentage depth doses affected significantly by the external scatter show a larger build-up dose. A forward shifted Dmax depth and a sharper fall-off region compared to PDDs with only internal scatter considered. The surface dose with both internal and external scatter shows a marked decrease at 110 cm SSD, and then slight further changes with the increasing SSD since few external scattered particles from accelerator model can reach the phantom for large SSDs. The sharp PDD increase for the 5 cm x 5 cm field compared to other fields seen when only internal scatter is considered is significantly less when external scatter is also present. The effect of external scatter on surface PDD is more pronounced for large fields than small fields (5 cm x 5 cm field)

  3. Total Skin Electron Beam Therapy in the Treatment of Mycosis Fungoides: A Review of Conventional and Low-Dose Regimens.

    Science.gov (United States)

    Chowdhary, Mudit; Chhabra, Arpit M; Kharod, Shivam; Marwaha, Gaurav

    2016-12-01

    Mycosis fungoides (MF) is the most prevalent subtype of cutaneous T-cell lymphoma, which is characterized by the proliferation of CD4 + T cells. While often an indolent disease, most patients eventually develop progression from isolated patches to tumors and finally nodal or visceral involvement. Treatment choice is largely based on disease burden, though prognostic factors such as disease stage, patient age, and extracutaneous involvement must be taken into consideration. Radiotherapy represents one of the most effective therapeutic modalities in the treatment of MF. Lymphocytes are exquisitely radiosensitive, and excellent responses are observed even with low doses of radiation. Total skin electron beam therapy (TSEBT) is a special technique that allows for the homogenous irradiation of the entire skin. There are well-documented radiation dose-response relationships for achieving a complete response. As such, TSEBT doses ≥ 30 Gy comprise the current standard of care. Although highly effective, most patients experience recurrent disease even after conventional-dose (≥ 30 Gy) TSEBT. In addition, toxicity is cumulatively dose dependent, and there is reluctance to administer multiple courses of conventional-dose TSEBT. Consequently, there has been renewed interest in determining the utility of TSEBT at lower total (≤ 30 Gy) doses. Advantages of low-total-dose (with standard dose per fraction) TSEBT include a shortened treatment course, the potential to minimize the risk of adverse events, and the opportunity to allow for retreatment in cases of disease recurrence. This comprehensive review compares the impact of different TSEBT dosing schemes on clinical outcomes of MF. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Evaluation of internal and external doses from $^{11}C$ produced in the air in high energy proton accelerator tunnels

    CERN Document Server

    Endo, A; Kanda, Y; Oishi, T; Kondo, K

    2001-01-01

    Air has been irradiated with high energy protons at the 12 GeV proton synchrotron to obtain the following parameters essential for the internal dose evaluation from airborne /sup 11/C produced through nuclear spallation reactions: the abundance of gaseous and particulate /sup 11/C, chemical forms, and particle size distribution. It was found that more than 98% of /sup 11/C is present as gas and the rest is aerosol. The gaseous components were only /sup 11/CO and /sup 11/CO/sub 2/ and their proportions were approximately 80% and 20%, respectively. The particulate /sup 11/C was found to be sulphate and/or nitrate aerosols having a log-normal size distribution; the measurement using a diffusion battery showed a geometric mean radius of 0.035 mu m and a geometric standard deviation of 1.8 at a beam intensity of 6.8*10/sup 11/ proton.pulse /sup -1/ and an irradiation time of 9.6 min. By taking the chemical composition and particle size into account, effective doses both from internal and from external exposures pe...

  5. Use of TL dosemeters for measuring doses of external gamma radiation in the vicinity of the Dukovany NPP

    International Nuclear Information System (INIS)

    Ohera, M.; Fiala, E.; Valasek, J.

    1992-01-01

    The results of measurement of the photon dose equivalent from external gamma radiation in the surroundings of the Dukovany nuclear power plant are given for 20 sites in southern Moravia over the 1984-1990 period, i.e., one year before starting up the plant and 6 years of its operation. CaSO 4 :Dy TL dosemeters were used, applying filtration with 0.5 mm Pb and 0.2 mm Pb + 0.6 mm Sn. Since 1989, the towns along the borders with Austria (Znojmo, Vranov, Mikulov) have been included, along with the Brno, Trebic, Zakrany, Ivancice and Jaromerice sites, into the national monitoring TL dosimetric network. The elevated doses at some sites come from the bedrock and are not caused by the operation of the plant. The effect of the Chernobyl accident on the dosemeter response is also evaluated. Comparison of the data prior to the Dukovany plant start-up (1984) and during the operation (1985-1990) give evidence that the operation of the power plant did not bring about any increase in the values monitored. (Z.S.). 3 tabs., 8 figs., 9 refs

  6. The effectiveness of various decontamination techniques for reducing external radiation doses to people living in an urban environment

    International Nuclear Information System (INIS)

    Brown, J.; Crick, M.J.; Hill, M.D.

    1988-01-01

    The NRPB has recently developed a dynamic model, EXPURT (EXPosure from Urban Radionuclide Transfer), that reflects the transfer processes that take place in the urban environment. Parameter values for the model have been derived from experiments performed in recent years in the United Kingdom and in Denmark. The model incorporates shielding properties of different types of buildings, and population habits to evaluate individual and population doses as a function of time after deposit. The original model has been extended to enable it to represent several techniques for decontaminating the various surfaces in the urban environment. These include hosing of impermeable surfaces, such as walls, roofs and paved areas, the removal or ploughing of soil/grass, and the replacement of building surfaces with new uncontaminated materials. The model has been used to examine the effectiveness of these various decontamination measures at reducing the external radiation doses to people living in urban areas. The importance of the time at which decontamination is performed is also discussed in this paper

  7. Analysis of bias effects on the total ionizing dose response in a 180 nm technology

    International Nuclear Information System (INIS)

    Liu Zhangli; Hu Zhiyuan; Zhang, Zhengxuan; Shao Hua; Chen Ming; Bi Dawei; Ning Bingxu; Zou Shichang

    2011-01-01

    The effects of gamma ray irradiation on the shallow trench isolation (STI) leakage current in a 180 nm technology are investigated. The radiation response is strongly influenced by the bias modes, gate bias during irradiation, substrate bias during irradiation and operating substrate bias after irradiation. We found that the worst case occurs under the ON bias condition for the ON, OFF and PASS bias mode. A positive gate bias during irradiation significantly enhances the STI leakage current, indicating the electric field influence on the charge buildup process during radiation. Also, a negative substrate bias during irradiation enhances the STI leakage current. However a negative operating substrate bias effectively suppresses the STI leakage current, and can be used to eliminate the leakage current produced by the charge trapped in the deep STI oxide. Appropriate substrate bias should be introduced to alleviate the total ionizing dose (TID) response, and lead to acceptable threshold voltage shift and subthreshold hump effect. Depending on the simulation results, we believe that the electric field distribution in the STI oxide is the key parameter influencing bias effects on the radiation response of transistor. - Highlights: → ON bias is the worst bias condition for the ON, PASS and OFF bias modes. → Larger gate bias during irradiation leads to more pronounced characteristic degradation. → TID induced STI leakage can be suppressed by negative operating substrate bias voltage. → Negative substrate bias during irradiation leads to larger increase of off-state leakage. → Electric field in the STI oxide greatly influences the device's radiation effect.

  8. Normal tissue tolerance to external beam radiation therapy: Cardiac structures; Dose de tolerance des tissus sains: le coeur

    Energy Technology Data Exchange (ETDEWEB)

    Doyen, J. [Service d' oncologie-radiotherapie, centre Antoine-Lacassagne, 06 - Nice (France); Giraud, P. [Universite Rene-Descartes Paris 5, 75 - Paris (France); Service d' oncologie-radiotherapie, hopital europeen Georges-Pompidou, 75 - Paris (France); Belkacemi, Y. [Faculte de medecine de Creteil, universite Paris 12, 94 - Creteil (France); Service d' oncologie-radiotherapie, CHU Henri-Mondor, 94 - Creteil (France)

    2010-07-15

    Radiation thoracic tumors may be associated with cardiac toxicity because of the central position of the heart in the thorax. The present review aims to describe the cardiotoxicity during radiotherapy of different tumor sites most associated with this complication and the risk factors of cardiotoxicity during radiation therapy. Medline literature searches were performed using the following cardiac - heart - radiotherapy - toxicity - cardiotoxicity - breast cancer - lymphoma. Cardiac toxicity after breast cancer and mediastinal lymphoma is the most reported radiation-induced complication. The most frequent clinical complications are pericarditis, congestive heart failure, and heart infarction. These events are mostly asymptomatic. Thus clinicians have to give particular attention to these complications. Anthracycline treatment is a major risk factor for additional cardiotoxicity during radiotherapy with a synergistic effect. Correction of cardiovascular risk is an important point of the prevention of heart complications. Total dose delivered to the planned target volume (PTV), the dose per fraction and the irradiated volume were correlated to the risk of cardiotoxicity. Volume of heart receiving 35 Gy must be inferior to 30% and dose per fraction should not exceed 2 Gy when dose of prescription exceeds 30 Gy. Maximum heart distance (maximal thickness of heart irradiated) must be less than 1 cm during irradiation of breast cancer. Modern irradiation techniques seem to be associated with a limited risk of heart complication. The use of anthracycline, other cardio-toxic chemotherapies and targeted therapies should incite for great caution by performing a careful treatment planning and optimisation. (authors)

  9. The international protocol for the dosimetry of external radiotherapy beams based on standards of absorbed dose to water

    International Nuclear Information System (INIS)

    Andreo, P.

    2001-01-01

    An International Code of Practice (CoP, or dosimetry protocol) for external beam radiotherapy dosimetry based on standards of absorbed dose to water has been published by the IAEA on behalf of IAEA, WHO, PAHO and ESTRO. The CoP provides a systematic and internationally unified approach for the determination of the absorbed dose to water in reference conditions with radiotherapy beams. The development of absorbed-dose-to-water standards for high-energy photons and electrons offers the possibility of reducing the uncertainty in the dosimetry of radiotherapy beams. Many laboratories already provide calibrations at the radiation quality of 60Co gamma-rays and some have extended calibrations to high-energy photon and electron beams. The dosimetry of kilovoltage x-rays, as well as that of proton and ion beams can also be based on these standards. Thus, a coherent dosimetry system based on the same formalism is achieved for practically all radiotherapy beams. The practical use of the CoP as simple. The document is formed by a set of different CoPs for each radiation type, which include detailed procedures and worksheets. All CoPs are based on ND,w chamber calibrations at a reference beam quality Qo, together with radiation beam quality correction factors kQ preferably measured directly for the user's chamber in a standards laboratory. Calculated values of kQ are provided together with their uncertainty estimates. Beam quality specifiers are 60Co, TPR20,10 (high-energy photons), R50 (electrons), HVL and kV (x-rays) and Rres (protons and ions) [es

  10. Evaluation of Total Daily Dose and Glycemic Control for Patients on U-500 Insulin Admitted to the Hospital

    Science.gov (United States)

    2016-05-20

    regular insulin has significantly increased in recent years. These patients are severely insulin resistant requiring high doses of insulin to achieve...on U-500 Insulin Admitted to the Hospital presented at SURF Conference, San Antonio, TX 20 May 201 6 with MDWI 41-108, and has been assigned local...59th CSPG/SGVU) C.201 4 . I 52d PROTOCOL TITLE Evaluation of Total Dai ly Dose and Glycemic Control for Patients on U-500 Insulin Admitted to the

  11. The effect of combined external beam and high-dose intracavitary brachytherapy on dysphagia and survival in patients with advanced esophageal cancer

    International Nuclear Information System (INIS)

    Yorozu, Atsunori; Dokiya, Takushi; Ogita, Mikio; Kutsuki, Shoji

    1996-01-01

    During an 11-year period, a group of 130 patients with esophageal cancer of stages 2 to 4 were treated with external beam irradiation (40 to 60 Gy) followed by boost dose of 10 to 20 Gy of high-dose intracavitary brachytherapy. The overall 2-year survival rate was 15.4%. The significant prognostic factors were tumor size, response to external beam irradiation, pretreatment dysphagia score, and presence of distant metastases. The palliative effect was excellent; the dysphagia scores of 122 of 130 patients (93.8%) improved. The significant palliative factors were response to external beam irradiation and pretreatment dysphagia score. Tracheoesophageal fistulas developed after treatment in 13 of 130 patients (10%); 3 of the fistulas were probably related to radiotherapy. We conclude that intracavitary brachytherapy is useful in the treatment of cases of advanced cancer which show a good response to external beam irradiation and may be curative in patients with mild dysphagia. (author)

  12. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    International Nuclear Information System (INIS)

    Lucero, J. F.; Rojas, J. I.

    2016-01-01

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  13. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    Energy Technology Data Exchange (ETDEWEB)

    Lucero, J. F., E-mail: fernando.lucero@hoperadiotherapy.com.gt [Universidad Nacional de Costa Rica, Heredia (Costa Rica); Hope International, Guatemala (Guatemala); Rojas, J. I., E-mail: isaac.rojas@siglo21.cr [Centro Médico Radioterapia Siglo XXI, San José (Costa Rica)

    2016-07-07

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  14. Clinical responses after total body irradiation by over permissible dose of γ-rays in one time

    International Nuclear Information System (INIS)

    Jiang Benrong; Wang Guilin; Liu Huilan; Tang Xingsheng; Ai Huisheng

    1990-01-01

    The clinical responses of patients after total body over permissilbe dose γ-ray irradiation were observed and analysed. The results showed: when the dose was above 5 cGy, there was some immunological depression, but no significant change in hematopoietic functions. 5 cases showed some transient changes of ECG, perhaps due to vagotonia caused by psychological imbalance, One case vomitted 3-4 times after 28 cGy irradiation, this suggested that a few times of vomitting had no significance in the estimation of the irradiated dose and the whole clinical manifestations must be concretely analysed

  15. Fast method for in-flight estimation of total dose from protons and electrons using RADE Minstrument on JUICE

    Science.gov (United States)

    Hajdas, Wojtek; Mrigakshi, Alankrita; Xiao, Hualin

    2017-04-01

    The primary concern of the ESA JUICE mission to Jupiter is the harsh particle radiation environment. Ionizing particles introduce radiation damage by total dose effects, displacement damages or single events effects. Therefore, both the total ionizing dose and the displacement damage equivalent fluence must be assessed to alert spacecraft and its payload as well as to quantify radiation levels for the entire mission lifetime. We present a concept and implementations steps for simplified method used to compute in flight a dose rate and total dose caused by protons. We also provide refinement of the method previously developed for electrons. The dose rates values are given for predefined active volumes located behind layers of materials with known thickness. Both methods are based on the electron and proton flux measurements provided by the Electron and Proton Detectors inside the Radiation Hard Electron Monitor (RADEM) located on-board of JUICE. The trade-off between method accuracy and programming limitations for in-flight computations are discussed. More comprehensive and precise dose rate computations based on detailed analysis of all stack detectors will be made during off-line data processing. It will utilize full spectral unfolding from all RADEM detector subsystems.

  16. Genitourinary Toxicity After High-Dose-Rate (HDR) Brachytherapy Combined With Hypofractionated External Beam Radiotherapy for Localized Prostate Cancer: An Analysis to Determine the Correlation Between Dose-Volume Histogram Parameters in HDR Brachytherapy and Severity of Toxicity

    International Nuclear Information System (INIS)

    Ishiyama, Hiromichi; Kitano, Masashi; Satoh, Takefumi; Kotani, Shouko; Uemae, Mineko; Matsumoto, Kazumasa; Okusa, Hiroshi; Tabata, Ken-ichi; Baba, Shiro; Hayakawa, Kazushige

    2009-01-01

    Purpose: To evaluate the severity of genitourinary (GU) toxicity in high-dose-rate (HDR) brachytherapy combined with hypofractionated external beam radiotherapy (EBRT) for prostate cancer and to explore factors that might affect the severity of GU toxicity. Methods and Materials: A total of 100 Japanese men with prostate cancer underwent 192 Ir HDR brachytherapy combined with hypofractionated EBRT. Mean (SD) dose to 90% of the planning target volume was 6.3 (0.7) Gy per fraction of HDR. After 5 fractions of HDR treatment, EBRT with 10 fractions of 3 Gy was administrated. The urethral volume receiving 1-15 Gy per fraction in HDR brachytherapy (V1-V15) and the dose to at least 5-100% of urethral volume in HDR brachytherapy (D5-D100) were compared between patients with Grade 3 toxicity and those with Grade 0-2 toxicity. Prostate volume, patient age, and International Prostate Symptom Score were also compared between the two groups. Results: Of the 100 patients, 6 displayed Grade 3 acute GU toxicity, and 12 displayed Grade 3 late GU toxicity. Regarding acute GU toxicity, values of V1, V2, V3, and V4 were significantly higher in patients with Grade 3 toxicity than in those with Grade 0-2 toxicity. Regarding late GU toxicity, values of D70, D80, V12, and V13 were significantly higher in patients with Grade 3 toxicity than in those with Grade 0-2 toxicity. Conclusions: The severity of GU toxicity in HDR brachytherapy combined with hypofractionated EBRT for prostate cancer was relatively high. The volume of prostatic urethra was associated with grade of acute GU toxicity, and urethral dose was associated with grade of late GU toxicity.

  17. High-dose total-body irradiation and autologous marrow reconstitution in dogs: dose-rate-related acute toxicity and fractionation-dependent long-term survival

    International Nuclear Information System (INIS)

    Deeg, H.J.; Storb, R.; Weiden, P.L.; Schumacher, D.; Shulman, H.; Graham, T.; Thomas, E.D.

    1981-01-01

    Beagle dogs treated by total-body irradiation (TBI) were given autologous marrow grafts in order to avoid death from marrow toxicity. Acute and delayed non-marrow toxicities of high single-dose (27 dogs) and fractionated TBI (20 dogs) delivered at 0.05 or 0.1 Gy/min were compared. Fractionated TBI was given in increments of 2 Gy every 6 hr for three increments per day. Acute toxicity and early mortality (<1 month) at identical total irradiation doses were comparable for dogs given fractionated or single-dose TBI. With single-dose TBI, 14, 16, and 18 Gy, respectively, given at 0.05 Gy/min, 0/5, 5/5, and 2/2 dogs died from acute toxicity; with 10, 12, and 14 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 5/5 dogs died acutely. With fractionated TBI, 14 and 16 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 2/2 dogs died auctely. Early deaths were due to radiation enteritis with or without associated septicemia (29 dogs; less than or equal to Day 10). Three dogs given 10 Gy of TBI at 0.1 Gy/min died from bacterial pneumonia; one (Day 18) had been given fractionated and two (Days 14, 22) single-dose TBI. Fifteen dogs survived beyond 1 month; eight of these had single-dose TBI (10-14 Gy) and all died within 7 months of irradiation from a syndrome consisting of hepatic damage, pancreatic fibrosis, malnutrition, wasting, and anemia. Seven of the 15 had fractionated TBI, and only one (14 Gy) died on Day 33 from hepatic failure, whereas 6 (10-14 Gy) are alive and well 250 to 500 days after irradiation. In conclusion, fractionated TBI did not offer advantages over single-dose TBI with regard to acute toxicity and early mortality; rather, these were dependent upon the total dose of TBI. The total acutely tolerated dose was dependent upon the exposure rate; however, only dogs given fractionated TBI became healthy long-term survivors

  18. Three-dimensional Finite Elements Method simulation of Total Ionizing Dose in 22 nm bulk nFinFETs

    Energy Technology Data Exchange (ETDEWEB)

    Chatzikyriakou, Eleni, E-mail: ec3g12@soton.ac.uk; Potter, Kenneth; Redman-White, William; De Groot, C.H.

    2017-02-15

    Highlights: • Simulation of Total Ionizing Dose using the Finite Elements Method. • Carrier generation, transport and trapping in the oxide. • Application in three-dimensional bulk FinFET model of 22 nm node. • Examination of trapped charge in the Shallow Trench Isolation. • Trapped charge dependency of parasitic transistor current. - Abstract: Finite Elements Method simulation of Total Ionizing Dose effects on 22 nm bulk Fin Field Effect Transistor (FinFET) devices using the commercial software Synopsys Sentaurus TCAD is presented. The simulation parameters are extracted by calibrating the charge trapping model to experimental results on 400 nm SiO{sub 2} capacitors irradiated under zero bias. The FinFET device characteristics are calibrated to the Intel 22 nm bulk technology. Irradiation simulations of the transistor performed with all terminals unbiased reveal increased hardness up to a total dose of 1 MRad(SiO{sub 2}).

  19. Measurement of soil contamination by radionuclides due to the Fukushima Dai-ichi Nuclear Power Plant accident and associated estimated cumulative external dose estimation

    International Nuclear Information System (INIS)

    Endo, S.; Kimura, S.; Takatsuji, T.; Nanasawa, K.; Imanaka, T.; Shizuma, K.

    2012-01-01

    Soil sampling was carried out at an early stage of the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident. Samples were taken from areas around FDNPP, at four locations northwest of FDNPP, at four schools and in four cities, including Fukushima City. Radioactive contaminants in soil samples were identified and measured by using a Ge detector and included 129m Te, 129 Te, 131 I, 132 Te, 132 I, 134 Cs, 136 Cs, 137 Cs, 140 Ba and 140 La. The highest soil depositions were measured to the northwest of FDNPP. From this soil deposition data, variations in dose rates over time and the cumulative external doses at the locations for 3 months and 1 y after deposition were estimated. At locations northwest of FDNPP, the external dose rate at 3 months after deposition was 4.8–98 μSv/h and the cumulative dose for 1 y was 51 to 1.0 × 10 3 mSv; the highest values were at Futaba Yamada. At the four schools, which were used as evacuation shelters, and in the four urban cities, the external dose rate at 3 months after deposition ranged from 0.03 to 3.8 μSv/h and the cumulative doses for 1 y ranged from 3 to 40 mSv. The cumulative dose at Fukushima Niihama Park was estimated as the highest in the four cities. The estimated external dose rates and cumulative doses show that careful countermeasures and remediation will be needed as a result of the accident, and detailed measurements of radionuclide deposition densities in soil will be important input data to conduct these activities.

  20. Dose rate and total dose dependence of the 1/f noise performance of a GaAs operational amplifier during irradiation

    International Nuclear Information System (INIS)

    Hiemstra, D.M.

    1995-01-01

    A pictorial of a sectioned view of the torus of the International Thermonuclear Experimental Reactor (ITER) is shown. Maintenance and inspection of the reactor are required to be performed remotely. This is due to the high gamma radiation environment in vessel during inspection and maintenance activities. The custom GaAs operational amplifier is to be used to readout sensors on the in-vessel manipulator and inspection equipment. The gamma dose rate during maintenance and inspection is anticipated to be 3 Mrad(GaAs)/hour. Here, dose rate and total dose dependence of the 1/f noise performance of a custom GaAs MESFET operational amplifier during irradiation are presented. Dose rate dependent 1/f noise degradation during irradiation is believed to be due to electron trapping in deep levels, enhanced by backgating and shallow traps excited during irradiation. The reduction of this affect with accumulated total dose is believed to be due a reduction of deep level site concentration associated with substitutional oxygen. Post irradiation 1/f noise degradation is also presented.The generation-recombination noise observed post irradiation can be attributed to the production of shallow traps due to ionizing radiation

  1. Central axis dose verification in patients treated with total body irradiation of photons using a Computed Radiography system

    International Nuclear Information System (INIS)

    Rubio Rivero, A.; Caballero Pinelo, R.; Gonzalez Perez, Y.

    2015-01-01

    To propose and evaluate a method for the central axis dose verification in patients treated with total body irradiation (TBI) of photons using images obtained through a Computed Radiography (CR) system. It was used the Computed Radiography (Fuji) portal imaging cassette readings and correlate with measured of absorbed dose in water using 10 x 10 irradiation fields with ionization chamber in the 60 Co equipment. The analytical and graphic expression is obtained through software 'Origin8', the TBI patient portal verification images were processed using software ImageJ, to obtain the patient dose. To validate the results, the absorbed dose in RW3 models was measured with ionization chamber with different thickness, simulating TBI real conditions. Finally it was performed a retrospective study over the last 4 years obtaining the patients absorbed dose based on the reading in the image and comparing with the planned dose. The analytical equation obtained permits estimate the absorbed dose using image pixel value and the dose measured with ionization chamber and correlated with patient clinical records. Those results are compared with reported evidence obtaining a difference less than 02%, the 3 methods were compared and the results are within 10%. (Author)

  2. Design of spray dried insulin microparticles to bypass deposition in the extrathoracic region and maximize total lung dose.

    Science.gov (United States)

    Ung, Keith T; Rao, Nagaraja; Weers, Jeffry G; Huang, Daniel; Chan, Hak-Kim

    2016-09-25

    Inhaled drugs all too often deliver only a fraction of the emitted dose to the target lung site due to deposition in the extrathoracic region (i.e., mouth and throat), which can lead to increased variation in lung exposure, and in some instances increases in local and systemic side effects. For aerosol medications, improved targeting to the lungs may be achieved by tailoring the micromeritic properties of the particles (e.g., size, density, rugosity) to minimize deposition in the mouth-throat and maximize the total lung dose. This study evaluated a co-solvent spray drying approach to modulate particle morphology and dose delivery characteristics of engineered powder formulations of insulin microparticles. The binary co-solvent system studied included water as the primary solvent mixed with an organic co-solvent, e.g., ethanol. Factors such as the relative rate of evaporation of each component of a binary co-solvent mixture, and insulin solubility in each component were considered in selecting feedstock compositions. A water-ethanol co-solvent mixture with a composition range considered suitable for modulating particle shell formation during drying was selected for experimental investigation. An Alberta Idealized Throat model was used to evaluate the in vitro total lung dose of a series of spray dried insulin formulations engineered with different bulk powder properties and delivered with two prototype inhalers that fluidize and disperse powder using different principles. The in vitro total lung dose of insulin microparticles was improved and favored for powders with low bulk density and small primary particle size, with reduction of deposition in the extrathoracic region. The results demonstrated that a total lung dose >95% of the delivered dose can be achieved with engineered particles, indicating a high degree of lung targeting, almost completely bypassing deposition in the mouth-throat. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Anatomy-based inverse optimization in high-dose-rate brachytherapy combined with hypofractionated external beam radiotherapy for localized prostate cancer: Comparison of incidence of acute genitourinary toxicity between anatomy-based inverse optimization and geometric optimization

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo; Katoh, Hiroyuki; Kitamoto, Yoshizumi; Shirai, Katsuyuki; Shioya, Mariko; Nakano, Takashi

    2006-01-01

    Purpose: To evaluate the advantages of anatomy-based inverse optimization (IO) in planning high-dose-rate (HDR) brachytherapy. Methods and Materials: A total of 114 patients who received HDR brachytherapy (9 Gy in two fractions) combined with hypofractionated external beam radiotherapy (EBRT) were analyzed. The dose distributions of HDR brachytherapy were optimized using geometric optimization (GO) in 70 patients and by anatomy-based IO in the remaining 44 patients. The correlation between the dose-volume histogram parameters, including the urethral dose and the incidence of acute genitourinary (GU) toxicity, was evaluated. Results: The averaged values of the percentage of volume receiving 80-150% of the prescribed minimal peripheral dose (V 8 -V 15 ) of the urethra generated by anatomy-based IO were significantly lower than the corresponding values generated by GO. Similarly, the averaged values of the minimal dose received by 5-50% of the target volume (D 5 -D 5 ) obtained using anatomy-based IO were significantly lower than those obtained using GO. Regarding acute toxicity, Grade 2 or worse acute GU toxicity developed in 23% of all patients, but was significantly lower in patients for whom anatomy-based IO (16%) was used than in those for whom GO was used (37%), consistent with the reduced urethral dose (p <0.01). Conclusion: The results of this study suggest that anatomy-based IO is superior to GO for dose optimization in HDR brachytherapy for prostate cancer

  4. Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study

    Science.gov (United States)

    Chen, Yingxuan; Yin, Fang-Fang; Zhang, Yawei; Zhang, You; Ren, Lei

    2018-04-01

    Purpose: compressed sensing reconstruction using total variation (TV) tends to over-smooth the edge information by uniformly penalizing the image gradient. The goal of this study is to develop a novel prior contour based TV (PCTV) method to enhance the edge information in compressed sensing reconstruction for CBCT. Methods: the edge information is extracted from prior planning-CT via edge detection. Prior CT is first registered with on-board CBCT reconstructed with TV method through rigid or deformable registration. The edge contours in prior-CT is then mapped to CBCT and used as the weight map for TV regularization to enhance edge information in CBCT reconstruction. The PCTV method was evaluated using extended-cardiac-torso (XCAT) phantom, physical CatPhan phantom and brain patient data. Results were compared with both TV and edge preserving TV (EPTV) methods which are commonly used for limited projection CBCT reconstruction. Relative error was used to calculate pixel value difference and edge cross correlation was defined as the similarity of edge information between reconstructed images and ground truth in the quantitative evaluation. Results: compared to TV and EPTV, PCTV enhanced the edge information of bone, lung vessels and tumor in XCAT reconstruction and complex bony structures in brain patient CBCT. In XCAT study using 45 half-fan CBCT projections, compared with ground truth, relative errors were 1.5%, 0.7% and 0.3% and edge cross correlations were 0.66, 0.72 and 0.78 for TV, EPTV and PCTV, respectively. PCTV is more robust to the projection number reduction. Edge enhancement was reduced slightly with noisy projections but PCTV was still superior to other methods. PCTV can maintain resolution while reducing the noise in the low mAs CatPhan reconstruction. Low contrast edges were preserved better with PCTV compared with TV and EPTV. Conclusion: PCTV preserved edge information as well as reduced streak artifacts and noise in low dose CBCT reconstruction

  5. Perspectives in absorbed dose metrology with regard to the technical evolutions of external beam radiotherapy; Perspectives en metrologie de la dose face aux evolutions techniques de la radiotherapie externe

    Energy Technology Data Exchange (ETDEWEB)

    Chauvenet, B.; Bordy, J.M. [CEA Saclay, Lab. National Henri Becquerel (LNE-LNHB), 91 - Gif-sur-Yvette (France); Barthe, J. [CEA Saclay (LIST), 91 - Gif-sur-Yvette (France)

    2009-07-01

    This paper presents several R and D axes in absorbed close metrology to meet the needs resulting from the technical evolutions of external beam radiotherapy. The facilities in operation in France have considerably evolved under the impulse of the plan Cancer launched in 2003: replacements and increase of the number of accelerators, substitution of accelerators for telecobalt almost completed and acquisition of innovative facilities for tomo-therapy and stereotaxy. The increasing versatility of facilities makes possible the rapid evolution of treatment modalities, allowing to better delimit irradiation to tumoral tissues and spare surrounding healthy tissues and organs at risk. This leads to a better treatment efficacy through dose escalation. National metrology laboratories must offer responses adapted to the new need, i.e. not restrict themselves to the establishment of references under conventional conditions defined at international level, contribute to the improvement of uncertainties at all levels of reference transfer to practitioners: primary measurements under conditions as close as possible to those of treatment, characterization of transfer and treatment control dosimeters., metrological validation of treatment planning tools... Those axes have been identified as priorities for the next years in ionizing radiation metrology at the European level and included in the European. Metrology Research Programme. A project dealing with some of those topics has been selected in the frame of the Eranet+ Call EMRP 2007 and is now starting. The LNE-LAM is strongly engaged in it. (authors)

  6. Low-dose external beam radiotherapy for greater trochanteric pain syndrome. Target volume definition and treatment outcome

    Energy Technology Data Exchange (ETDEWEB)

    Kaltenborn, Alexander [Federal Armed Forces Hospital Westerstede, Department of Orthopedic and Trauma Surgery, Westerstede (Germany); Hannover Medical School, Core Facility Quality Management and Health Technology Assessment in Transplantation, Integrated Research and Treatment Center Transplantation (IFB-Tx), Hannover (Germany); Carl, Ulrich Martin; Hinsche, Tanja [Center for Radiotherapy and Radiooncology Bremen and Westerstede, Westerstede (Germany); Nitsche, Mirko [Center for Radiotherapy and Radiooncology Bremen and Westerstede, Westerstede (Germany); University of Schleswig Holstein, Campus Kiel, Department of Radiotherapy, Karl-Lennert Cancer Center, Kiel (Germany); Hermann, Robert Michael [Center for Radiotherapy and Radiooncology Bremen and Westerstede, Westerstede (Germany); Hannover Medical School, Department of Radiotherapy and Special Oncology, Hannover (Germany)

    2017-04-15

    Low-dose external beam radiotherapy (ED-EBRT) is frequently used in the therapy of refractory greater trochanteric pain syndrome (GTPS). As studies reporting treatment results are scarce, we retrospectively analyzed our own patient collectives. In all, 60 patients (74 hips) received LD-EBRT (6 x 0.5 Gy in 29 hips, 6 x 1 Gy in 45). The endpoint was the patient's reported subjective response to treatment. The influence of different patient and treatment characteristics on treatment outcome was investigated. At the end of LD-EBRT, 69% reported partial remission, 4% complete remission, no change 28%. A total of 3 months later (n = 52 hips), the results were 37, 33, and 30% and 18 months after LD-EBRT (n = 47) 21, 51, and 28%. In univariate analysis ''inclusion of the total femoral head into the PTV'' and ''night pain before LD-EBRT'' were correlated with symptom remission at the end of LD-EBRT, while ''initial increase in pain during LD-EBRT'' was significantly associated with treatment failure. In multivariable modeling ''initial increase in pain'' was identified as a risk factor for treatment failure (p = 0.007; odds ratio [OR] 0.209; 95% confidence interval [CI] 0.048-0.957), while ''night pain'' was an independent factor for remission (p = 0.038; OR 3.484; 95% CI 1.004-12.6). Three months after LD-EBRT ''night pain'' and ''inclusion of the complete femoral neck circumference into the PTV'' were predictive for remission. LD-EBRT represents a useful treatment option for patients suffering from GTPS. Three months after therapy two-thirds of the patients reported a partial or complete symptom remission. Especially patients who suffered from nocturnal pain seemed to benefit. Treatment appeared to be more effective when the entire circumference of the femoral neck was encompassed. (orig.) [German] In der Behandlung des

  7. Application of a Pelletron accelerator to study total dose radiation effects on 50 GHz SiGe HBTs

    Energy Technology Data Exchange (ETDEWEB)

    Praveen, K.C.; Pushpa, N.; Naik, P.S. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570 006 (India); Cressler, John D. [School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA (United States); Tripathi, Ambuj [Inter University Accelerator Centre (IUAC), New Delhi 110 067 (India); Gnana Prakash, A.P., E-mail: gnanaprakash@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570 006 (India)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer Total dose effects of 50 MeV Li3+ ion on 50 GHz SiGe HBTs is investigated. Black-Right-Pointing-Pointer Ion irradiated results were compared with Co-60 gamma results. Black-Right-Pointing-Pointer 50 MeV Li ions create more damage in E-B spacer oxide when compared to Co-60 gamma radiation. Black-Right-Pointing-Pointer Co-60 gamma radiation create more damage in STI oxide when compared to 50 MeV Li ions. Black-Right-Pointing-Pointer Worst case total dose radiation effects can be studied using Pelletron accelerator facilities. - Abstract: We have investigated the effects of 50 MeV lithium ion irradiation on the DC electrical characteristics of first-generation silicon-germanium heterojunction bipolar transistors (50 GHz SiGe HBTs) in the dose range of 600 krad to 100 Mrad. The results of 50 MeV Li{sup 3+} ion irradiation on the SiGe HBTs are compared with 63 MeV proton and Co-60 gamma irradiation results in the same dose range in order to understand the damage induced by different LET species. The radiation response of emitter-base (EB) spacer oxide and shallow trench isolation (STI) oxide to different irradiation types are discussed in this paper. We have also focused on the efficacy in the application of a Pelletron accelerator to study total dose irradiation studies in SiGe HBTs.

  8. Normal tissue tolerance to external beam radiation therapy: Skin; Dose de tolerance des tissus sains: la peau et les phaneres

    Energy Technology Data Exchange (ETDEWEB)

    Ginot, A.; Doyen, J.; Hannoun-Levi, J.M.; Courdi, A. [Service d' oncologie-radiotherapie, centre Antoine-Lacassagne, 06 - Nice (France)

    2010-07-15

    Acute skin toxicity is frequent during radiation therapy and can lead to temporary arrest of the treatment. Chronic toxicity can occur and conduct to cosmetic problems. Alopecia is the most frequent toxicity concerning hair and is most of the time reversible. Several factors linked to patients influence skin toxicity, such as under-nutrition, old age, obesity, smoking, skin diseases, autoimmune diseases, failure of DNA reparation. Skin, hair and nail toxicities depend also on radiation schedule. Acute toxicity is greater when dose per fraction increases. Chronic and acute toxicities are more often when total dose increases. Under 45 Gy, the risk of severe skin toxicity is low, and begins above 50 Gy. Skin toxicity depends also on the duration of radiotherapy and split course schedules are associated with less toxicities. Irradiation surface seems to influence skin toxicity but interaction is more complex. Reirradiation is often feasible in case of cancer recurrence but with a risk of grade 3-4 toxicity above all in head and neck cancer. The benefit/risk ratio has to be always precisely evaluated. Permanent alopecia is correlated with the follicle dose. Modern techniques of radiation therapy allow to spare skin. (authors)

  9. Total heat loss coefficient of flat roof constructions with external insulation in tapered layers including the effects of thermal bridges

    DEFF Research Database (Denmark)

    Rose, Jørgen; Svendsen, Svend

    2005-01-01

    In order to achieve durability of flat roofs with external insulation, it is necessary to secure proper drainage of the roof, i.e. to avoid water leaking into the insulation. The design of the tapered insulation of the roof is quite difficult as requirements with respect to both drainage...

  10. Quantifying the spatial and temporal variation in dose from external exposure to radiation: a new tool for use on free-ranging wildlife

    International Nuclear Information System (INIS)

    Hinton, Thomas G.; Byrne, Michael E.; Webster, Sarah; Beasley, James C.

    2015-01-01

    Inadequate dosimetry is often the fundamental problem in much of the controversial research dealing with radiation effects on free-ranging wildlife. Such research is difficult because of the need to measure dose from several potential pathways of exposure (i.e., internal contamination, external irradiation, and inhalation). Difficulties in quantifying external exposures can contribute significantly to the uncertainties of dose-effect relationships. Quantifying an animal's external exposure due to spatial–temporal use of habitats that can vary by orders of magnitude in radiation levels is particularly challenging. Historically, wildlife dosimetry studies have largely ignored or been unable to accurately quantify variability in external dose because of technological limitations. The difficulties of quantifying the temporal–spatial aspects of external irradiation prompted us to develop a new dosimetry instrument for field research. We merged two existing technologies [Global Positioning Systems (GPS) and electronic dosimeters] to accommodate the restrictive conditions of having a combined unit small enough to be unobtrusively worn on the neck of a free-ranging animal, and sufficiently robust to withstand harsh environmental conditions. The GPS–dosimeter quantifies the spatial and temporal variation in external dose as wildlife traverse radioactively contaminated habitats and sends, via satellites, an animal's location and short term integrated dose to the researcher at a user-defined interval. Herein we describe: (1) the GPS–dosimeters; (2) tests to compare their uniformity of response to external irradiation under laboratory conditions; (3) field tests of their durability when worn on wildlife under natural conditions; and (4) a field application of the new technology at a radioactively contaminated site. Use of coupled GPS–dosimetry will allow, for the first time, researchers to better understand the relationship of animals to their contaminated

  11. Prostate-specific antigen bounce after high-dose rate brachytherapy with external beam radiation therapy for prostate cancer patients

    International Nuclear Information System (INIS)

    Sakamoto, Naotaka; Kakinoki, Hiroaki; Tsutsui, Akio; Yoshikawa, Masahiro; Iguchi, Atsushi; Matsunobu, Toru; Uehara, Satoru

    2008-01-01

    Prostate-specific antigen (PSA) bounce after high-dose rate (HDR) brachytherapy with external beam radiation therapy (EBRT) for prostate cancer patients was evaluated. Sixty-one patients treated with HDR-brachytherapy followed by EBRT had a minimum follow-up of 12 months (median, 24 months) in our institute. A PSA bounce was defined as a rise of at least 0.1 ng/ml greater than a previous PSA level, with a subsequent decline equal to, or less than, the initial nadir. A PSA bounce was noted in 16 (26.2%) of 61 patients (one patient had a PSA bounce twice). Median time to develop a PSA bounce was 18 months, but 23.5% developed a PSA bounce after 24 months. Median duration of PSA bounce was 6 months and 11.8% had increased PSA within a period of 12 months. Median bounce height was 0.2 ng/ml (range, 0.1 to 3.39 ng/ml). A bounce height of gerater than 2 ng/ml was seen in 11.8%. Clinical characteristics (age, prostate volume, neoadjuvant endocrine therapy, risk classification, stage, pretreatment PSA, Gleason score) do not predict whether or not there will be a PSA bounce. In patients treated with HDR-brachytherapy followed by EBRT, the incidence and characteristics of PSA bounce were similar to those in patients treated with low-dose rate brachytherapy. Physicians should be aware of the possibility of PSA bounce following HDR-brachytherapy with EBRT. (author)

  12. Intralesional Versus Oral Chloroquine in Cutaneous Leishmaniasis: Comparison of Outcome, Duration of Treatment and Total Dose of Drug

    International Nuclear Information System (INIS)

    Hanif, M. M.; Akram, K.; Mustafa, G.

    2016-01-01

    Objective: To compare intralesional versus oral chloroquine in cutaneous leishmaniasis and determine the cure rate, duration of treatment, and total dose of drug. Study Design: Randomized controlled study. Place and Duration of Study: Department of Dermatology, Sheikh Zayed Medical College/Hospital, Rahim Yar Khan, from November 2013 to June 2014. Methodology: Consecutive 86 patients of cutaneous leishmaniasis, with single to multiple lesions of various sizes were enrolled and divided randomly into group A and B for the purpose of intralesional and oral chloroquine administration, respectively to compare the effect of the two routes on duration of treatment and total dose of the drug. SPSS version 16 was used for data analysis after data entry into it. Quantitative variables like, duration, cost and total dose of treatment were calculated as mean and standard deviation and compared by using T-test. P-value of less than 0.05 was taken as significant. Results: Cure rate was 100% in both groups towards the end of treatment. Mean duration of treatment was 9.17 ± 3 weeks in intralesional (A) group as against 11.37 ± 3 weeks in oral (B) group (p = 0.0028). Mean total dose of the drug given to each patient in group A was 5.8 ± 0.5 gm and in group B, it was 19.2 ± 1.5 gm, which is significantly higher (p=0.001). The total cost of treatment in group A was Rs. 90 ± 8 and in group B it was Rs. 91 ± 1 (p=0.446). Conclusion: Duration of treatment is significantly shorter and total dose is lesser with intralesional compared to oral chloroquine in treatment of cutaneous leishmaniasis. (author)

  13. 85Kr management trade-offs: a perspective to total radiation dose commitment

    International Nuclear Information System (INIS)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for 85 Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether 85 Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person

  14. 85Kr management trade-offs: a perspective to total radiation dose commitment

    Energy Technology Data Exchange (ETDEWEB)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for /sup 85/Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether /sup 85/Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person (<0.001% of natural background radiation for the same time period).

  15. Effect of Gold Nanoparticles on Prostate Dose Distribution under Ir-192 Internal and 18 MV External Radiotherapy Procedures Using Gel Dosimetry and Monte Carlo Method

    Directory of Open Access Journals (Sweden)

    Khosravi H.

    2015-03-01

    Full Text Available Background: Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions. Objective: The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC method for studying the effect of gold nanoparticles (GNPs in prostate dose distributions under the internal Ir-192 and external 18MV radiotherapy practices. Method: A Plexiglas phantom was made representing human pelvis. The GNP shaving 15 nm in diameter and 0.1 mM concentration were synthesized using chemical reduction method. Then, a new formulation of MAGIC-f gel was synthesized. The fabricated gel was poured in the tubes located at the prostate (with and without the GNPs and bladder locations of the phantom. The phantom was irradiated to an Ir-192 source and 18 MV beam of a Varian linac separately based on common radiotherapy procedures used for prostate cancer. After 24 hours, the irradiated gels were read using a Siemens 1.5 Tesla MRI scanner. The absolute doses at the reference points and isodose curves resulted from the experimental measurement of the gels and MC simulations following the internal and external radiotherapy practices were compared. Results: The mean absorbed doses measured with the gel in the presence of the GNPs in prostate were 15% and 8 % higher than the corresponding values without the GNPs under the internal and external radiation therapies, respectively. MC simulations also indicated a dose increase of 14 % and 7 % due to presence of the GNPs, for the same experimental internal and external radiotherapy practices, respectively. Conclusion: There was a good agreement between the dose enhancement factors (DEFs estimated with MC simulations and experiment gel measurements due to the GNPs. The results indicated that the polymer gel dosimetry method as developed and used in this study, can be recommended as a reliable method for investigating the DEF of GNPs in internal

  16. Effect of Gold Nanoparticles on Prostate Dose Distribution under Ir-192 Internal and 18 MV External Radiotherapy Procedures Using Gel Dosimetry and Monte Carlo Method.

    Science.gov (United States)

    Khosravi, H; Hashemi, B; Mahdavi, S R; Hejazi, P

    2015-03-01

    Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions. The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC) method for studying the effect of gold nanoparticles (GNPs) in prostate dose distributions under the internal Ir-192 and external 18MV radiotherapy practices. A Plexiglas phantom was made representing human pelvis. The GNP shaving 15 nm in diameter and 0.1 mM concentration were synthesized using chemical reduction method. Then, a new formulation of MAGIC-f gel was synthesized. The fabricated gel was poured in the tubes located at the prostate (with and without the GNPs) and bladder locations of the phantom. The phantom was irradiated to an Ir-192 source and 18 MV beam of a Varian linac separately based on common radiotherapy procedures used for prostate cancer. After 24 hours, the irradiated gels were read using a Siemens 1.5 Tesla MRI scanner. The absolute doses at the reference points and isodose curves resulted from the experimental measurement of the gels and MC simulations following the internal and external radiotherapy practices were compared. The mean absorbed doses measured with the gel in the presence of the GNPs in prostate were 15% and 8 % higher than the corresponding values without the GNPs under the internal and external radiation therapies, respectively. MC simulations also indicated a dose increase of 14 % and 7 % due to presence of the GNPs, for the same experimental internal and external radiotherapy practices, respectively. There was a good agreement between the dose enhancement factors (DEFs) estimated with MC simulations and experiment gel measurements due to the GNPs. The results indicated that the polymer gel dosimetry method as developed and used in this study, can be recommended as a reliable method for investigating the DEF of GNPs in internal and external radiotherapy practices.

  17. Recent advances in understanding total-dose effects in bipolar transistors

    International Nuclear Information System (INIS)

    Schrimpf, R.D.

    1996-01-01

    Gain degradation in irradiated bipolar transistors can be a significant problem, particularly in linear integrated circuits. In many bipolar technologies, the degradation is greater for irradiation at low dose rates than it is for typical laboratory dose rates. Ionizing radiation causes the base current in bipolar transistors to increase, due to the presence of net positive charge in the oxides covering sensitive device areas and increases in surface recombination velocity. Understanding the mechanisms responsible for radiation-induced gain degradation in bipolar transistors is important in developing appropriate hardness assurance methods. This paper reviews recent modeling and experimental work, with the emphasis on low-dose-rate effects. A promising hardness assurance method based on irradiation at elevated temperatures is described

  18. Serum level modifications of female sex hormones after radiocastration with different total doses

    International Nuclear Information System (INIS)

    Naujokat, B.; Rohloff, R.; Willich, N.; Eiermann, W.

    1988-01-01

    We determined serum level of estradiol, FSH and LH over a period of six to eight weeks after ovarian irradiation for castration with different doses (2x2.5 Gy/3x2.5 Gy/4x2.5 Gy) in 15 patients with metastatic breast cancer as compared to changes after ovarectomy in five patients. The time course of the changing estradiol-, FSH and LH-serum levels sigificantly depends on the ovarian dose. After radiological castration with a dose of 4x2.5 Gy = 10 Gy in four days the estrogen levels decrease within two to three weeks, and the FSH- and LH-levels increase after three to four weeks into the postmenopausal range. Therefore, the time course is not very different from changes after ovarectomy. (orig.) [de

  19. A prospective, open-label study of low-dose total skin electron beam therapy in mycosis fungoides

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Specht, Lena; Skovgaard, Gunhild L

    2008-01-01

    causes and did not complete treatment. Acute side effects included desquamation, xerosis, and erythema of the skin. No severe side effects were observed. CONCLUSION: Low-dose total skin electron beam therapy can induce complete and partial responses in Stage IB-II mycosis fungoides; however, the duration......PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years......]) with histopathologically confirmed mycosis fungoides T2-T4 N0-N1 M0 who did not achieve complete remission or relapsed within 4 months after treatment with psoralen plus ultraviolet-A were included. Treatment consisted of low-dose total skin electron beam therapy administered at a total skin dose of 4 Gy given in 4...

  20. Use of an electron reflector to improve dose uniformity at the vertex during total skin electron therapy

    International Nuclear Information System (INIS)

    Peters, V.G.

    2000-01-01

    Purpose: The vertex of the scalp is always tangentially irradiated during total skin electron therapy (TSET). This study was conducted to determine the dose distribution at the vertex for a commonly used irradiation technique and to evaluate the use of an electron reflector, positioned above the head, as a means of improving the dose uniformity. Methods and Materials: Phantoms, simulating the head of a patient, were irradiated using our standard procedure for TSET. The technique is a six-field irradiation using dual angled electron beams at a treatment distance of 3.6 meters. Vertex dosimetry was performed using ionization methods and film. Measurements were made for an unmodified 6 MeV electron beam and for a 4 MeV beam obtained by placing an acrylic scattering plate in the beam line. Studies were performed to examine the effect of electron scattering on vertex dose when a lead reflector, 50 x 50 cm in area, was positioned above the phantom. Results: The surface dose at the vertex, in the absence of the reflector, was found to be less than 40% of the prescribed skin dose. Use of the lead reflector increased this value to 73% for the 6 MeV beam and 99% for the degraded 4 MeV beam. Significant improvements in depth dose were also observed. The dose enhancement is not strongly dependent on reflector distance or angulation since the reflector acts as a large source of broadly scattered electrons. Conclusion: The vertex may be significantly underdosed using standard techniques for total skin electron therapy. Use of an electron reflector improves the dose uniformity at the vertex and may reduce or eliminate the need for supplemental irradiation

  1. Cumulative total effective whole-body radiation dose in critically ill patients.

    Science.gov (United States)

    Rohner, Deborah J; Bennett, Suzanne; Samaratunga, Chandrasiri; Jewell, Elizabeth S; Smith, Jeffrey P; Gaskill-Shipley, Mary; Lisco, Steven J

    2013-11-01

    Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.

  2. The effects of dose rate in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Bodenberger, U.; Holler, E.; Thierfelder, S.; Eckstein, R.

    1986-01-01

    In summary the studies in dogs show that the dose rate or exposure time has a great impact on survival of acute radiation syndromes. In contrast the inactivation of colony forming hemopoietic precursors is less influenced by the dose rate. The potential of hemopoietic recovery is determined by the survival of hemopoietic precursor cells. Therefore in patients with a suspected whole body exposure of more than 1.50 Gy, bacterial and fungal decontamination and reverse isolation in a sterile environment has to be started immediately. Human patients treated with about 10 Gy of TBI frequently developed nausea, elevated temperatures and swelling of the parotic glands at the first and second day. The extent of these changes varies from patient to patient. The temperature is rarely elevated above 38.5 0 C. The swelling of parotics and the nausea subside within 48 hours. The presence of such systemic symptoms may suggest the exposure to a lethal dose of radiation. The disappearance of immature red cells, i.e. reticulocytes, and bandforms of granulocytes within the first 5 days supports this suggestion. HLA typing of the victim and his family should be performed as soon as possible after the accident. An HLA-identical sibling would be a suitable bone marrow donor. Unlike therapeutic TBI accidental exposures bring about uncertainties in the calculation of dose, dose distribution and dose rate. Early after irradiation biological changes are extremely variable. Both biological and physical data have to be considered, when microbiological decontamination, reverse isolation and transplantation of bone marrow are to be decided upon. Obviously these intensive therapeutic efforts are limited to a small number of victims. (orig.)

  3. Preoperative external beam radiotherapy and reduced dose brachytherapy for carcinoma of the cervix: survival and pathological response

    International Nuclear Information System (INIS)

    Jacinto, Alexandre A; Maia, Maria AC; Fogaroli, Ricardo C; Castilho, Marcus S; Novaes, Paulo ERS; Novick, Pablo R; Viani, Gustavo A; Salvajoli, João V; Ferrigno, Robson; Pellizzon, Antonio Cássio A; Lima, Stella SS

    2007-01-01

    To evaluate the pathologic response of cervical carcinoma to external beam radiotherapy (EBRT) and high dose rate brachytherapy (HDRB) and outcome. Between 1992 and 2001, 67 patients with cervical carcinoma were submitted to preoperative radiotherapy. Sixty-five patients were stage IIb. Preoperative treatment included 45 Gy EBRT and 12 Gy HDRB. Patients were submitted to surgery after a mean time of 82 days. Lymphadenectomy was performed in 81% of patients. Eleven patients with residual cervix residual disease on pathological specimen were submitted to 2 additional insertions of HDRB. median follow up was 72 months. Five-year cause specific survival was 75%, overall survival 65%, local control 95%. Complete pelvic pathological response was seen in 40%. Surgery performed later than 80 days was associated with pathological response. Pelvic nodal involvement was found in 12%. Complete pelvic pathological response and negative lymphnodes were associated with better outcome (p = .03 and p = .005). Late grade 3 and 4 urinary and intestinal adverse effects were seen in 12 and 2% of patients. Time allowed between RT and surgery correlated with pathological response. Pelvic pathological response was associated with improved outcome. Postoperative additional HDRB did not improve therapeutic results. Treatment was well tolerated

  4. Individualised dosimetry in patients with differentiated thyroid cancer based on external dose-rate. Optimisation of the number of measurements.

    Science.gov (United States)

    Bautista-Ballesteros, J A; Torres-Espallardo, I; Borrelli, P; Rivas-Sanchez, A; Bello, P; Martí-Bonmatí, L

    2016-01-01

    To compare the results of individual dosimetry in differentiated thyroid cancer patients treated with (131)I at our centre with the established limits and dosimetry results of published studies. Analysis of the optimal number of measurements necessary to reduce the impact of dosimetry for the comfort of the patient and, secondly, on the workload of health workers. Dosimetry was performed in the Nuclear Medicine Department of the University and Polytechnic Hospital La Fe, on 29 patients suffering from differentiated thyroid cancer and treated with activities between 1.02 and 5.51 GBq (mean 2.68 GBq) of (131)I. The Spanish Society of Medical Physics (SEFM) protocol was used, based on measurements of external dose rate adjusted to a bi-exponential curve according to a two compartment model. Different dosimetries were performed on each patient, taking different selections of the available measurements in order to find the optimal number. Results are well below the dosimetry limits, and are consistent with those obtained in other centres. The number of measurements can be reduced from 5, as proposed in the SEFM protocol, to 4 without significant loss of accuracy. Further reducing measures may be justified in individual cases. The values obtained for the dosimetry quantities are significantly below the established limits. A reduction in measurements can be assumed at the cost of a moderate increase in uncertainty, benefiting the patient. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  5. Prediction of total dose effects on sub-micron process metal oxide semiconductor devices

    International Nuclear Information System (INIS)

    Kamimura, Hiroshi; Kato, Masataka.

    1991-01-01

    A method for correcting leakage currents is described to predict the radiation-induced threshold voltage shift of sub-micron MOSFETs. A practical model for predicting the leakage current generated by irradiation is also given on the basis of experimental results on 0.8-μm process MOSFETs. The constants in the threshold voltage shift model are determined from the 'true' I-V characteristic of the MOSFET, which is obtained by correction of leakage currents due to characteristic change of a parasitic transistor. In this way, the threshold voltage shift of the n-channel MOSFET irradiated at a low dose rate of 2 Gy(Si)/h was also calculated by using data from a high dose rate irradiation experiment (100 Gy(Si)/h, 5 h). The calculated result well represented the tendency of measured data on threshold voltage shift. The radiation-induced leakage current was considered to decay approximately in two exponential modes. The constants in this leakage current model were determined from the above high dose rate experiment. The response of leakage current predicted at a low dose rate of 2 Gy(Si)/h approximately agreed with that measured during and after irradiation. (author)

  6. Total dose effects on elementary transistors of a comparator in bipolar technology

    International Nuclear Information System (INIS)

    Sarrabayrouse, G.; Guerre, F.X.

    1995-01-01

    In the present work we investigate elementary transistors behaviour of an Integrated Circuit using junction isolation bipolar technology. Polarization conditions and dose rate effects on the main elementary transistor types are analysed. Furthermore, the IC electronic function degradations are studied. Finally, a comparison between the function degradations and the elementary component ones is attempted. (author)

  7. Improving anatomical mapping of complexly deformed anatomy for external beam radiotherapy and brachytherapy dose accumulation in cervical cancer

    International Nuclear Information System (INIS)

    Vásquez Osorio, Eliana M.; Kolkman-Deurloo, Inger-Karine K.; Schuring-Pereira, Monica; Zolnay, András; Heijmen, Ben J. M.; Hoogeman, Mischa S.

    2015-01-01

    Purpose: In the treatment of cervical cancer, large anatomical deformations, caused by, e.g., tumor shrinkage, bladder and rectum filling changes, organ sliding, and the presence of the brachytherapy (BT) applicator, prohibit the accumulation of external beam radiotherapy (EBRT) and BT dose distributions. This work proposes a structure-wise registration with vector field integration (SW+VF) to map the largely deformed anatomies between EBRT and BT, paving the way for 3D dose accumulation between EBRT and BT. Methods: T2w-MRIs acquired before EBRT and as a part of the MRI-guided BT procedure for 12 cervical cancer patients, along with the manual delineations of the bladder, cervix-uterus, and rectum-sigmoid, were used for this study. A rigid transformation was used to align the bony anatomy in the MRIs. The proposed SW+VF method starts by automatically segmenting features in the area surrounding the delineated organs. Then, each organ and feature pair is registered independently using a feature-based nonrigid registration algorithm developed in-house. Additionally, a background transformation is calculated to account for areas far from all organs and features. In order to obtain one transformation that can be used for dose accumulation, the organ-based, feature-based, and the background transformations are combined into one vector field using a weighted sum, where the contribution of each transformation can be directly controlled by its extent of influence (scope size). The optimal scope sizes for organ-based and feature-based transformations were found by an exhaustive analysis. The anatomical correctness of the mapping was independently validated by measuring the residual distances after transformation for delineated structures inside the cervix-uterus (inner anatomical correctness), and for anatomical landmarks outside the organs in the surrounding region (outer anatomical correctness). The results of the proposed method were compared with the results of the

  8. Improving anatomical mapping of complexly deformed anatomy for external beam radiotherapy and brachytherapy dose accumulation in cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vásquez Osorio, Eliana M., E-mail: e.vasquezosorio@erasmusmc.nl; Kolkman-Deurloo, Inger-Karine K.; Schuring-Pereira, Monica; Zolnay, András; Heijmen, Ben J. M.; Hoogeman, Mischa S. [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam 3075 (Netherlands)

    2015-01-15

    Purpose: In the treatment of cervical cancer, large anatomical deformations, caused by, e.g., tumor shrinkage, bladder and rectum filling changes, organ sliding, and the presence of the brachytherapy (BT) applicator, prohibit the accumulation of external beam radiotherapy (EBRT) and BT dose distributions. This work proposes a structure-wise registration with vector field integration (SW+VF) to map the largely deformed anatomies between EBRT and BT, paving the way for 3D dose accumulation between EBRT and BT. Methods: T2w-MRIs acquired before EBRT and as a part of the MRI-guided BT procedure for 12 cervical cancer patients, along with the manual delineations of the bladder, cervix-uterus, and rectum-sigmoid, were used for this study. A rigid transformation was used to align the bony anatomy in the MRIs. The proposed SW+VF method starts by automatically segmenting features in the area surrounding the delineated organs. Then, each organ and feature pair is registered independently using a feature-based nonrigid registration algorithm developed in-house. Additionally, a background transformation is calculated to account for areas far from all organs and features. In order to obtain one transformation that can be used for dose accumulation, the organ-based, feature-based, and the background transformations are combined into one vector field using a weighted sum, where the contribution of each transformation can be directly controlled by its extent of influence (scope size). The optimal scope sizes for organ-based and feature-based transformations were found by an exhaustive analysis. The anatomical correctness of the mapping was independently validated by measuring the residual distances after transformation for delineated structures inside the cervix-uterus (inner anatomical correctness), and for anatomical landmarks outside the organs in the surrounding region (outer anatomical correctness). The results of the proposed method were compared with the results of the

  9. Dose-rate conversion factors for external exposure to photon and electron radiation from radionuclides occurring in routine releases from nuclear fuel cycle facilities

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1980-01-01

    Dose-rate conversion factors for external exposure to photon and electron radiation are calculated for 240 radionuclides of potential importance in routine releases from nuclear fuel cycle facilities. Exposure modes considered are immersion in contaminated air, immersion in contaminated water, and irradiation from a contaminated ground surface. For each exposure mode, dose-rate conversion factors for photons and electrons are calculated for tissue-equivalent material at the body surface of an exposed individual. Dose-rate conversion factors for photons only are calculated for 22 body organs. (author)

  10. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  11. Total Ionizing Dose Effects on Threshold Switching in 1T-Tantalum Disulfide Charge-Density-Wave Devices

    OpenAIRE

    Liu, G.; Zhang, E. X.; Liang, C. D.; Bloodgood, M. A.; Salguero, T. T.; Fleetwood, D. M.; Balandin, A. A.

    2017-01-01

    The 1T polytype of TaS2 exhibits voltage-triggered threshold switching as a result of a phase transition from nearly commensurate to incommensurate charge density wave states. Threshold switching, persistent above room temperature, can be utilized in a variety of electronic devices, e.g., voltage controlled oscillators. We evaluated the total-ionizing-dose response of thin film 1T-TaS2 at doses up to 1 Mrad(SiO2). The threshold voltage changed by less than 2% after irradiation, with persisten...

  12. High total dose proton irradiation effects on silicon NPN rf power transistors

    International Nuclear Information System (INIS)

    Bharathi, M. N.; Praveen, K. C.; Prakash, A. P. Gnana; Pushpa, N.

    2014-01-01

    The effects of 3 MeV proton irradiation on the I-V characteristics of NPN rf power transistors were studied in the dose range of 100 Krad to 100 Mrad. The different electrical characteristics like Gummel, current gain and output characteristics were systematically studied before and after irradiation. The recovery in the I-V characteristics of irradiated NPN BJTs were studied by isochronal and isothermal annealing methods

  13. High total dose proton irradiation effects on silicon NPN rf power transistors

    Energy Technology Data Exchange (ETDEWEB)

    Bharathi, M. N.; Praveen, K. C.; Prakash, A. P. Gnana, E-mail: gnanaprakash@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore-570006, Karnataka (India); Pushpa, N. [Department of PG Studies in Physics, JSS College, Ooty Road, Mysore-570025, Karnataka (India)

    2014-04-24

    The effects of 3 MeV proton irradiation on the I-V characteristics of NPN rf power transistors were studied in the dose range of 100 Krad to 100 Mrad. The different electrical characteristics like Gummel, current gain and output characteristics were systematically studied before and after irradiation. The recovery in the I-V characteristics of irradiated NPN BJTs were studied by isochronal and isothermal annealing methods.

  14. Quality assurance technique for absorbed dose distribution in external radiation therapy with non-physical wedges in consideration of the character of the imaging plate

    International Nuclear Information System (INIS)

    Fujibuchi, Toshioh; Fujisaki, Tatsuya; Kurokawa, Masayuki; Sakae, Takeji

    2011-01-01

    The film dose distribution method is used for profile measurements of non-physical wedges, because three-dimensional automatic control water phantoms cannot be used. Recently, many hospitals have adopted computed radiography (CR) systems in preference to automatic developing processors and films. This may allow use of automatic processors to be discontinued. In this study, a beam was irradiated to an Imaging Plate (IP), and then IP was exposed to a fixed amount of light with fading, and we then measured the off-center ratio (OCR) absorbed dose distribution in external radiation therapy with non-physical wedge. This was compared with the OCR measured with an ionization chamber dosimeter. It was consequently possible for IP to approximate the value measured by the ionization chamber dosimeter by using a metal filter. This method offers a simple quality assurance technique for absorbed dose distribution in external radiation therapy with non-physical wedges in consideration of the character of the IP. (author)

  15. Impact of total radiotherapy dose on survival for head and neck Merkel cell carcinoma after resection.

    Science.gov (United States)

    Patel, Sagar A; Qureshi, Muhammad M; Mak, Kimberley S; Sahni, Debjani; Giacalone, Nicholas J; Ezzat, Waleed; Jalisi, Scharukh; Truong, Minh Tam

    2017-07-01

    Head and neck Merkel cell carcinoma (MCC) is commonly treated with surgery and adjuvant radiotherapy (RT) for high-risk features. The optimal radiation dose is unknown. One thousand six hundred twenty-five eligible patients with head and neck MCC were identified in the National Cancer Data Base (NCDB). Radiation dose was divided into 3 groups: 30 to 55-70 Gy. Cox regression was used to compare overall survival (OS) between groups, accounting for age, sex, stage, surgery type, margin status, comorbidities, and use of chemotherapy. With a median follow-up of 33.5 months, 3-year OS was 48.9%, 70.3%, and 58.7% for 30 to 55-70 Gy, respectively (P 55-70 Gy (adjusted HR 1.21; 95% CI 1.0-1.46; P = .06) were associated with worse survival. Adjuvant radiation doses within 50-55 Gy may be optimal for head and neck MCC. © 2017 Wiley Periodicals, Inc.

  16. External beam radiation therapy and a low-dose-rate brachytherapy boost without or with androgen deprivation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Strom, Tobin J.; Hutchinson, Sean Z.; Shrinath, Kushagra; Cruz, Alex A.; Figura, Nicholas B.; Nethers, Kevin; Biagioli, Matthew C.; Fernandez, Daniel C.; Heysek, Randy V.; Wilder, Richard B., E-mail: richard.wilder@moffitt.org [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States)

    2014-07-15

    Purpose: To assess outcomes with external beam radiation therapy (EBRT) and a low-dose-rate (LDR) brachytherapy boost without or with androgen deprivation therapy (ADT) for prostate cancer. Materials and Methods: From January 2001 through August 2011, 120 intermediate-risk or high-risk prostate cancer patients were treated with EBRT to a total dose of 4,500 cGy in 25 daily fractions and a palladium-103 LDR brachytherapy boost of 10,000 cGy (n = 90) or an iodine-125 LDR brachytherapy boost of 11,000 cGy (n = 30). ADT, consisting of a gonadotropin-releasing hormone agonist ± an anti-androgen, was administered to 29/92 (32%) intermediate-risk patients for a median duration of 4 months and 26/28 (93%) high-risk patients for a median duration of 28 months. Results: Median follow-up was 5.2 years (range, 1.1-12.8 years). There was no statistically-significant difference in biochemical disease-free survival (bDFS), distant metastasis-free survival (DMFS), or overall survival (OS) without or with ADT. Also, there was no statistically-significant difference in bDFS, DMFS, or OS with a palladium-103 vs. an iodine-125 LDR brachytherapy boost. Conclusions: There was no statistically-significant difference in outcomes with the addition of ADT, though the power of the current study was limited. The Radiation Therapy Oncology Group 0815 and 0924 phase III trials, which have accrual targets of more than 1,500 men, will help to clarify the role ADT in locally-advanced prostate cancer patients treated with EBRT and a brachytherapy boost. Palladium-103 and iodine-125 provide similar bDFS, DMFS, and OS. (author)

  17. High-Dose-Rate Brachytherapy of a Single Implant With Two Fractions Combined With External Beam Radiotherapy for Hormone-Naive Prostate Cancer

    International Nuclear Information System (INIS)

    Sato, Morio; Mori, Takashi; Shirai, Shintaro; Kishi, Kazushi; Inagaki, Takeshi; Hara, Isao

    2008-01-01

    Purpose: To evaluate the preliminary outcomes of high-dose-rate (HDR) brachytherapy of a single implant with two fractions and external beam radiotherapy (EBRT) for hormone-naive prostate cancer. Methods and Materials: Between March 2000 and Sept 2003, a total of 53 patients with tumor Stage T1c-T3b N0 M0 prostate cancer were treated with HDR brachytherapy boost doses (7.5 Gy/fraction) and 50-Gy EBRT during a 5.5-week period. Median follow-up was 61 months. Patients were divided into groups with localized (T1c-T2b) and advanced disease (T3a-T3b). We used the American Society for Therapeutic Radiology and Oncology (ASTRO) definition for biochemical failure. According to recommendations of the Radiation Therapy Oncology Group-ASTRO Phoenix Consensus Conference, biochemical failure-free control rates (BF-FCRs) at 3 years were investigated as 2 years short of the median follow-up. Results: Between April 2000 and Sept 2007, Common Terminology Criteria for Adverse Events Version 2.0 late Grade 2 genitourinary and gastrointestinal toxicity rates were 0% and 3.8%, respectively. Erectile preservation was 25% at 5 years. Overall survival was 88.1% and cause-specific survival was 100%. At 3 years, ASTRO BF-FCRs of the localized and advanced groups were 100% and 42%, respectively (p = 0.001). Conclusions: The HDR brachytherapy of a single implant with two fractions plus EBRT is effective in treating patients with localized hormone-naive prostate cancer, with the least genitourinary and gastrointestinal toxicities; however, longer median BF-FCR follow-up is required to assess these findings

  18. High-Dose-Rate Brachytherapy and External-Beam Radiotherapy for Hormone-Naïve Low- and Intermediate-Risk Prostate Cancer: A 7-Year Experience

    International Nuclear Information System (INIS)

    Aluwini, Shafak; Rooij, Peter H. van; Kirkels, Wim J.; Jansen, Peter P.; Praag, John O.; Bangma, Chris H.; Kolkman-Deurloo, Inger-Karine K.

    2012-01-01

    Purpose: To report clinical outcomes and early and late complications in 264 hormone-naïve patients with low- and intermediate-risk prostate cancer treated with high-dose-rate brachytherapy (HDR-BT) in combination with external-beam radiotherapy (EBRT). Methods and Materials: Between February 2000 and July 2007, 264 patients underwent HDR-BT in combination with EBRT as a treatment for their low- to intermediate-risk prostate cancer. The HDR-BT was performed using ultrasound-based implantation. The total HDR-BT dose was 18 Gy in 3 fractions within 24 h, with a 6-h minimum interval. The EBRT started 2 weeks after HDR-BT and was delivered in 25 fractions of 1.8 Gy to 45 Gy within 5 weeks. Results: After a mean follow-up of 74.5 months, 4 patients (1.5%) showed prostate-specific antigen progression according to the American Society for Radiation Oncology definition and 8 patients (3%) according to the Phoenix definition. A biopsy-proven local recurrence was registered in 1 patient (0.4%), and clinical progression (bone metastases) was documented in 2 patients (0.7%). Seven-year actuarial freedom from biochemical failure was 97%, and 7-year disease-specific survival and overall survival were 100% and 91%, respectively. Toxicities were comparable to other series. Conclusions: Treatment with interstitial HDR-BT plus EBRT shows a low incidence of late complications and a favorable oncologic outcome after 7 years follow-up.

  19. Concentration of total proteins in blood plasma of chickens hatched from irradiated eggs with low dose gamma radiation

    International Nuclear Information System (INIS)

    Vilic, M.; Kraljevic, P.; Miljanic, S.; Simpraga, M.

    2005-01-01

    It is known that low-dose ionising radiation may have stimulating effects on chickens. Low doses may also cause changes in the concentration of blood plasma total proteins, glucose and cholesterol in chickens. This study investigates the effects of low dose gamma-radiation on the concentration of total proteins in the blood plasma of chickens hatched from eggs irradiated with a dose of 0.15 Gy on incubation days 7 and 19. Results were compared with the control group (chickens hatched from non-irradiated eggs). After hatching, all other conditions were the same for both groups. Blood samples were drawn from the heart, and later from the wing vein on days 1, 3, 5, 7,10, 20, 30 and 42. The concentration of total proteins was determined spectrophotometrically using Boehringer Mannheim GmbH optimised kits. The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 7 showed a statistically significant decrease on the sampling day 3 (P less than 0.05) and 7 (P less than 0.01). The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 19 showed a statistically significant increase only on sampling day 1 (P less than 0.05). These results suggest that exposure of eggs to 0.15 Gy of gamma-radiation on the 7th and 19th day of incubation could produce different effects on the protein metabolism in chickens.(author)

  20. Low Dose Gamma Irradiation Does Not Affect the Quality or Total Ascorbic Acid Concentration of "Sweetheart" Passionfruit (Passiflora edulis).

    Science.gov (United States)

    Golding, John B; Blades, Barbara L; Satyan, Shashirekha; Spohr, Lorraine J; Harris, Anne; Jessup, Andrew J; Archer, John R; Davies, Justin B; Banos, Connie

    2015-08-26

    Passionfruit ( Passiflora edulis , Sims, cultivar "Sweetheart") were subject to gamma irradiation at levels suitable for phytosanitary purposes (0, 150, 400 and 1000 Gy) then stored at 8 °C and assessed for fruit quality and total ascorbic acid concentration after one and fourteen days. Irradiation at any dose (≤1000 Gy) did not affect passionfruit quality (overall fruit quality, colour, firmness, fruit shrivel, stem condition, weight loss, total soluble solids level (TSS), titratable acidity (TA) level, TSS/TA ratio, juice pH and rot development), nor the total ascorbic acid concentration. The length of time in storage affected some fruit quality parameters and total ascorbic acid concentration, with longer storage periods resulting in lower quality fruit and lower total ascorbic acid concentration, irrespective of irradiation. There was no interaction between irradiation treatment and storage time, indicating that irradiation did not influence the effect of storage on passionfruit quality. The results showed that the application of 150, 400 and 1000 Gy gamma irradiation to "Sweetheart" purple passionfruit did not produce any deleterious effects on fruit quality or total ascorbic acid concentration during cold storage, thus supporting the use of low dose irradiation as a phytosanitary treatment against quarantine pests in purple passionfruit.

  1. Radiobiological basis of total body irradiation with different dose rate and fractionation: repair capacity of hemopoietic cells

    International Nuclear Information System (INIS)

    Song, C.W.; Kim, T.H.; Khan, F.M.; Kersey, J.H.; Levitt, S.H.

    1981-01-01

    Total body irradiation (TBI) followed by bone marrow transplantation is being used in the treatment of malignant or non-malignant hemopoietic disorders. It has been believed that the ability of hemopoietic cells to repair sublethal radiation damage is negligible. Therefore, several schools of investigators suggested that TBI in a single exposure at extremely low dose rate (5 rad/min) over several hours, or in several fractions in 2-3 days, should yield a higher therapeutic gain, as compared with a single exposure at a high dose rate (26 rad/min). We reviewed the existing data in the literature, in particular, the response of hemopoietic cells to fractionated doses of irradiation and found that the repair capacity of both malignant and non-malignant hemopoietic cells might be greater than has been thought. It is concluded that we should not underestimate the ability of hemopoietic cells to repair sublethal radiation damage in using TBI

  2. Treatment of age-related subfoveal choroidal neovascularization by low-dose external radiation. A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Harino, Seiyo; Oshima, Yusuke; Tsujikawa, Kaoru; Oh, Ami; Sugimoto, Kiyoshi [Yodogawa Christian Hospital, Osaka (Japan); Murayama, Shigeyuki; Inoue, Toshihiko

    1997-04-01

    We applied low dose external beam radiation (6MV) to 17 eyes of 17 patients (Mean age 70.9 years, range 58-85) who had subfoveal choroidal neovascularization associated with age-related macular degeneration. None of the cases were suitable for photocoagulation according to the Macular Photo-coagulation Study protocol, and no feeding vessels underlying choroidal neovascular membrane could be detected. Corrected visual acuity ranged from 0.02 to 0.6 before treatment. The patients were divided into two groups. One group of 11 eyes was treated with 10 Gy and the other group of 6 eyes with 21 Gy. Mean follow up period was 347{+-}89 (mean{+-}standard deviation) days in the 10 Gy group and 312{+-}100 days in the 21 Gy group. We evaluated the outcome as `effective` if no progression in neovascular membrane was found by ophthalmoscopic and angiographic examination. Only 3 eyes (21%) of patients in the 10 Gy group and 2 eyes (33%) in 21 Gy group showed any effect. Although the rate of progression in choroidal neovascular membrane was significantly smaller in the 10 and 21 Gy group than in the controls, the corrected visual acuity in the treated group was not improved over that of the controls. No serious complications were seen. Only one case showed a stabilized neovascular membrane in the control group of 7 patients. Although the present results seem to be worse than those in previous reports, the efficacy of this treatment still needs to be evaluated because no beneficial strategies in the treatment of subfoveal neovascularization have been established. (author)

  3. Total and single doses influence the effectiveness of radiotherapy in palliative treatment of plasmacytoma

    Energy Technology Data Exchange (ETDEWEB)

    Stoelting, T.; Knauerhase, H.; Klautke, G. [Dept. of Radiotherapy, Univ. of Rostock (Germany); Kundt, G. [Inst. for Medical Informatics and Biometry, Univ. of Rostock (Germany); Fietkau, R. [Dept. of Radiotherapy, Univ. of Rostock (Germany); Dept. of Radiotherapy, Univ. of Erlangen (Germany)

    2008-09-15

    Purpose: in a retrospective analysis of radiotherapy of plasmacytomas, the effectiveness and the prognostic factors in regard to pain reduction and recalcification were evaluated. Patients and methods: 138 patients (70 women, 68 men; 15-86 years, median 61 years) were irradiated at 272 target volumes (TVs) from January 1970 to December 2003. Results: in 192/225 TVs (85.3%), there was a pain reduction. The recalcification rate was 44.7% (51/114 TVs). Significant parameters for pain relief in the multivariate analysis were completeness of therapy (odds ratio [OR] 87.8; p < 0.001 vs. interruption), patients < 60 years (OR 23.0; p < 0.001 vs. {>=} 70 years), and a single dose of 2 Gy (OR 11.0; p = 0.027 vs. 4-15.0 Gy). Significant parameters for recalcification in the multivariate analysis were concurrent chemotherapy (OR 12.3; p < 0.001 vs. no chemotherapy), no fractures in the TV (OR 5.9; p < 0.004 vs. fracture), and a dose of 40-< 50 Gy (OR 21.9; p = 0.035 vs. < 30 Gy) or {>=} 50 Gy (OR 26.4; p = 0.033 vs. < 30 Gy). Conclusion: radiotherapy is a very effective palliative treatment. Patients with a reduced general condition, with multiple bone lesions and a poor prognosis profit from short-term schemes (e.g., 1 x 8 Gy to 10 x 3 Gy). Patients in good general condition with a life expectancy of > 1 year and an osteolysis at risk of fracture, should be treated with doses up to 40-50 Gy (20-25 x 2 Gy), in order to achieve the best possible recalcification and pain relief. (orig.)

  4. What do unsuccessful radiographs contribute to the total radiation dose to a patient

    International Nuclear Information System (INIS)

    Roth, J.; Nemec, H.W.

    1985-01-01

    Prevention of, or reduction of, unnecessary exposure to radiation is one of the prime goals of radiological protection in diagnostic radiology. The paper explains the advantages of a new approach, namely to achieve optimum focussing and adjustment of radiation sources for difficult imaging tasks by way of the fluoroscopic rather than the collimator method. The patient's exposure during this preliminary examination on the average will amount to 25 p.c. of the doses applied by the subsequent radiograph; on the other hand, this approach will reduce the number of unsuccessful pictures. (orig.) [de

  5. On revealing the vertical structure of nanoparticle films with elemental resolution: A total external reflection X-ray standing waves study

    Energy Technology Data Exchange (ETDEWEB)

    Zargham, Ardalan, E-mail: zargham@ifp.uni-bremen.d [Institute of Solid State Physics, University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen (Germany); Schmidt, Thomas; Flege, Jan Ingo; Sauerbrey, Marc; Hildebrand, Radowan [Institute of Solid State Physics, University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen (Germany); Roehe, Sarah; Baeumer, Marcus [Applied and Physical Chemistry, University of Bremen, Leobener Str. 2, 28359, Bremen (Germany); Falta, Jens [Institute of Solid State Physics, University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen (Germany)

    2010-02-15

    We present a promising combination of methods to precisely determine the morphology of nanostructures, drawing on the example of monodisperse CoPt{sub 3} nanoparticle films deposited by spin coating and dip coating techniques on functionalized Au substrates. Ex-situ X-ray standing waves in total external reflection combined with X-ray reflectivity measurements were employed to determine element-specific atomic-density distributions in vertical direction.

  6. Total-dose radiation-induced degradation of thin film ferroelectric capacitors

    International Nuclear Information System (INIS)

    Schwank, J.R.; Nasby, R.D.; Miller, S.L.; Rodgers, M.S.; Dressendorfer, P.V.

    1990-01-01

    Thin film PbZr y Ti 1-y O 3 (PZT) ferroelectric memories offer the potential for radiation-hardened, high-speed nonvolatile memories with good retention and fatigue properties. In this paper we explore in detail the radiation hardness of PZT ferroelectric capacitors. Ferroelectric capacitors were irradiated using x-ray and Co-60 sources to dose levels up to 16 Mrad(Si). The capacitors were characterized for their memory properties both before and after irradiation. The radiation hardness was process dependent. Three out of four processes resulted in capacitors that showed less than 30% radiation-induced degradation in retained polarization charge and remanent polarization after irradiating to 16 Mrad(Si). On the other hand, one of the processes showed significant radiation-induced degradation in retained polarization charge and remanent polarization at dose levels above 1 Mrad(Si). The decrease in retained polarization charge appears to be due to an alteration of the switching characteristics of the ferroelectric due to changes in the internal fields. The radiation-induced degradation is recoverable by a postirradiation biased anneal and can be prevented entirely if devices are cycled during irradiation. The authors have developed a model to simulate the observed degradation

  7. Preliminary Radiation Analysis of the Total Ionizing Dose for the Resource Prospector Mission

    Science.gov (United States)

    Rojdev, Kristina; Tylka, Allan J.; Atwell, William

    2015-01-01

    NASA's Resource Prospector (RP) is a collaborative project between multiple centers and institutions to search for volatiles at the polar regions of the Moon as a potential resource for oxygen and propellant production. The mission is rated Class D and will be the first In-Situ Resource Utilization (ISRU) demonstration on the lunar surface and at the lunar poles. Given that this mission is rated Class D, the project is considering using commercial off the shelf (COTS) electronics parts to reduce cost. However, COTS parts can be more susceptible to space radiation than typical aerospace electronic parts and carry some additional risk. Thus, prior to parts selection, having a better understanding of the radiation environment can assist designers in the parts selection process. The focus of this paper is to provide a preliminary analysis of the radiation environment from launch, through landing on the surface, and some surface stay as an initial step in determining worst case mission doses to assist designers in screening out electronic parts that would not meet the potential dose levels experienced on this mission.

  8. Low-dose 4D cone-beam CT via joint spatiotemporal regularization of tensor framelet and nonlocal total variation

    Science.gov (United States)

    Han, Hao; Gao, Hao; Xing, Lei

    2017-08-01

    Excessive radiation exposure is still a major concern in 4D cone-beam computed tomography (4D-CBCT) due to its prolonged scanning duration. Radiation dose can be effectively reduced by either under-sampling the x-ray projections or reducing the x-ray flux. However, 4D-CBCT reconstruction under such low-dose protocols is prone to image artifacts and noise. In this work, we propose a novel joint regularization-based iterative reconstruction method for low-dose 4D-CBCT. To tackle the under-sampling problem, we employ spatiotemporal tensor framelet (STF) regularization to take advantage of the spatiotemporal coherence of the patient anatomy in 4D images. To simultaneously suppress the image noise caused by photon starvation, we also incorporate spatiotemporal nonlocal total variation (SNTV) regularization to make use of the nonlocal self-recursiveness of anatomical structures in the spatial and temporal domains. Under the joint STF-SNTV regularization, the proposed iterative reconstruction approach is evaluated first using two digital phantoms and then using physical experiment data in the low-dose context of both under-sampled and noisy projections. Compared with existing approaches via either STF or SNTV regularization alone, the presented hybrid approach achieves improved image quality, and is particularly effective for the reconstruction of low-dose 4D-CBCT data that are not only sparse but noisy.

  9. EFFECT OF EXTERNAL ENVIRONMENT ORGANIZATION AND APPLICATION OF TOTAL QUALITY MANAGEMENT (TQM AND PERFORMANCE OF THE COMPANY AND ITS EFFECT ON COMPETITIVE ADVANTAGE IN PTISM BOGASARI FLOURMILLS, JAKARTA

    Directory of Open Access Journals (Sweden)

    Ana Retno Mawarti

    2016-04-01

    Full Text Available This research aimed to discover the impact of external environment and Total Quality Management implementation on company performance in order to create competitive advantage in PT. ISM Bogasari Flourmills. This research is an associative explanatory research with quantitative method. The data sources used are primary data and secondary data. The primary data collected by spreading 122 questionnaires to employees of PT. ISM Bogasari on chief officers level, assistant manager level, and manager level. Sampling method used is Proportion able Stratified Random Sampling. The result showed that external environment with indicator of complexity, dynamics and environment carrying capacity, has positive and significant impact on company’s performance. Total Quality Management implementation with indicators of costumer focus, continuous refinement and staff training program, brings positive and significant impact on company’s performance. The company’s performance with its indicators of efficiency, effectiveness, and adaptability, has positive and significant impact on the creation of competitive advantage. The Research also proved that external environment and Total Quality Management Implementation directly affect the creation of competitive advantage.

  10. Clinical results of entrance dose in vivo dosimetry for high energy photons in external beam radiotherapy using MOSFETs

    International Nuclear Information System (INIS)

    Morton, J. P.; Bhat, M.; Williams, T.; Kovendy, A.

    2007-01-01

    Full text: Thomson and Nielsen T N -502 R D MOSFETs were used for entrance dose in vivo dosimetry for 6 and 10 MV photons. A total of 24 patients were tested, 10 breast. 8 prostate, 5 lung and 1 head and neck. For prostates three fields were checked. For all other plans all fields were checked. An action threshold of 8% was set for any one field and 5% for all fields combined. The total number of fields tested was 56, with a mean discrepancy of 1.4% and S.D. of 2.6%. Breasts had a mean discrepancy of 1.8% and S.D. of 2.8%. Prostates had a mean discrepancy of 1.3% and S.D. of 2.9%. For 3 fields combined, prostates had a mean of 1.3% and S.D. of 1.8%. These results are similar to results obtained with diodes and TLDs for the same techniques.

  11. Effects on Ferroelectric Thin-Film Stacks and Devices for Piezoelectric MEMS Applications at Varied Total Ionizing Dose (TID)

    Science.gov (United States)

    2017-03-01

    non -linearly mobile internal interfaces, e.g. domain walls and eventual phase boundaries. Radiation exposure is expected...zirconate titanate; PZT; actuator; radiation ; gamma; total ionization dose; TID; top electrode; Pt; IrO2; polarization; PE; hysteresis; permittivity...Hayashigawa, et. al., “A 2 Mbit Radiation Hardened Stackable Ferroelectric Memory” Non - Volatile Memory Technology Symposium, NVMTS 07, Nov 10-13, 2007 Albuquerque, NM, USA

  12. Acute genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo; Ito, Kazuto; Saitoh, Jun-ichi; Noda, Shin-ei; Harashima, Koichi; Sakurai, Hideyuki; Nakayama, Yuko; Yamamoto, Takumi; Suzuki, Kazuhiro; Nakano, Takashi; Niibe, Hideo

    2005-01-01

    Purpose: Several investigations have revealed that the α/β ratio for prostate cancer is atypically low, and that hypofractionation or high-dose-rate (HDR) brachytherapy regimens using appropriate radiation doses may be expected to yield tumor control and late sequelae rates that are better or at least as favorable as those achieved with conventional radiation therapy. In this setting, we attempted treating localized prostate cancer patients with HDR brachytherapy combined with hypofractionated external beam radiation therapy (EBRT). The purpose of this study was to evaluate the feasibility of using this approach, with special emphasis on the relationship between the severity of acute genitourinary (GU) toxicity and the urethral dose calculated from the dose-volume histogram (DVH) of HDR brachytherapy. Methods and Materials: Between September 2000 and December 2003, 70 patients with localized prostate cancer were treated by iridium-192 HDR brachytherapy combined with hypofractionated EBRT at the Gunma University Hospital. Hypofractionated EBRT was administered in fraction doses of 3 Gy, three times per week; a total dose of 51 Gy was delivered to the prostate gland and the seminal vesicles using the four-field technique. No elective pelvic irradiation was performed. After the completion of EBRT, all the patients additionally received transrectal ultrasonography (TRUS)-guided HDR brachytherapy. The fraction size and the number of fractions in HDR brachytherapy were prospectively changed, whereas the total radiation dose for EBRT was fixed at 51 Gy. The fractionation in HDR brachytherapy was as follows: 5 Gy x 5, 7 Gy x 3, 9 Gy x 2, administered twice per day, although the biologic effective dose (BED) for HDR brachytherapy combined with EBRT, assuming that the α/β ratio is 3, was almost equal to 138 in each fractionation group. The planning target volume was defined as the prostate gland with 5-mm margin all around, and the planning was conducted based on

  13. Total and single doses influence the effectiveness of radiotherapy in palliative treatment of plasmacytoma

    International Nuclear Information System (INIS)

    Stoelting, T.; Knauerhase, H.; Klautke, G.; Kundt, G.; Fietkau, R.

    2008-01-01

    Purpose: in a retrospective analysis of radiotherapy of plasmacytomas, the effectiveness and the prognostic factors in regard to pain reduction and recalcification were evaluated. Patients and methods: 138 patients (70 women, 68 men; 15-86 years, median 61 years) were irradiated at 272 target volumes (TVs) from January 1970 to December 2003. Results: in 192/225 TVs (85.3%), there was a pain reduction. The recalcification rate was 44.7% (51/114 TVs). Significant parameters for pain relief in the multivariate analysis were completeness of therapy (odds ratio [OR] 87.8; p 1 year and an osteolysis at risk of fracture, should be treated with doses up to 40-50 Gy (20-25 x 2 Gy), in order to achieve the best possible recalcification and pain relief. (orig.)

  14. Models for Total-Dose Radiation Effects in Non-Volatile Memory

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Philip Montgomery; Wix, Steven D.

    2017-04-01

    The objective of this work is to develop models to predict radiation effects in non- volatile memory: flash memory and ferroelectric RAM. In flash memory experiments have found that the internal high-voltage generators (charge pumps) are the most sensitive to radiation damage. Models are presented for radiation effects in charge pumps that demonstrate the experimental results. Floating gate models are developed for the memory cell in two types of flash memory devices by Intel and Samsung. These models utilize Fowler-Nordheim tunneling and hot electron injection to charge and erase the floating gate. Erase times are calculated from the models and compared with experimental results for different radiation doses. FRAM is less sensitive to radiation than flash memory, but measurements show that above 100 Krad FRAM suffers from a large increase in leakage current. A model for this effect is developed which compares closely with the measurements.

  15. ESCLOUD: A computer program to calculate the air concentration, deposition rate and external dose rate from a continuous discharge of radioactive material to atmosphere

    International Nuclear Information System (INIS)

    Jones, J.A.

    1980-03-01

    Radioactive material may be discharged to atmosphere in small quantities during the normal operation of a nuclear installation as part of a considered waste management practice. Estimates of the individual and collective dose equivalent rates resulting from such a discharge are required in a number of contexts: for example, in assessing compliance with dose limits, in estimating the radiological impact of the discharge and as an input into optimisation studies. The suite of programs which has been developed to undertake such calculations is made up of a number of independent modules one of which, ESCLOUD, is described in this report. The ESCLOUD program evaluates, as a function of distance and direction from the release point, the air concentration, deposition rate and external β and γ doses from airborne and deposited activity. The air concentration and deposition rate can be used as input to other modules for calculating inhalation and ingestion doses. (author)

  16. Individual external monitoring system for gamma and X ray evaluation of the individual dose equivalent 'HP(10)', utilizing a photographic dosimetry technique

    International Nuclear Information System (INIS)

    Santoro, Christiana; Filho, Joao Antonio

    2008-01-01

    Full text: Individual monitoring evaluates external sources of ionizing radiation X, γ, β and n, to which workers are occupationally exposed, for ensuring safe and acceptable radiological conditions in their places of employment. The dose received by workers should attend the limits authorized by national regulatory organs. Nowadays, there are two radiometric unit systems, based on resolutions of the National Nuclear Energy Commission (NNEC) and the International Commission on Radiation Units and Measurements (ICRU); in the conventional (NNEC) system, the doses received by workers are evaluated through the individual dose H x , where dosemeters used on surface of thorax are calibrated in terms of air kerma; in the recent system (ICRU), the doses are evaluated through the individual dose equivalent H P (d), where dosemeters are calibrated in terms of dose from phantom. The recent system improves the method of evaluation, by taking into account the scattering effect and absorption of radiation in the human body. This work adapts a photographic dosimetry service to the recent ICRU publications, for evaluation of individual monitoring, in function of the individual dose equivalent H P (10) of strong penetrating radiation. For this, a methodology based on linear programming and determination of calibration curves is used for radiation capacities, wide (W) and narrow (N) spectra, as described by the International Organization for Standardization (ISO 4037-1, 1995). These calibration curves offer better accuracy in the determination of doses and energy, which will improve the quality of the service given to society. The results show that the values of individual dose equivalent, evaluated at intervals of 0.2 to 200 mSv, have lower significant uncertainties (10%) than those recommended by the ICRP 75, for individual monitoring; therefore, the evaluation system for developed doses attends the new recommendations proposed by International Commissions. From what has been

  17. External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting.

    Science.gov (United States)

    Yoo, Song Jae; Jang, Han-Ki; Lee, Jai-Ki; Noh, Siwan; Cho, Gyuseong

    2013-01-01

    For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the Reference Male and Female Phantoms and the revised tissue weighting factors, as well as the updated decay data of radionuclides. In this study, the DCFs for effective and equivalent doses were calculated for three exposure settings: skyshine, groundshine and water immersion. Doses to the Reference Phantoms were calculated by Monte Carlo simulations with the MCNPX 2.7.0 radiation transport code for 26 mono-energy photons between 0.01 and 10 MeV. The transport calculations were performed for the source volume within the cut-off distances practically contributing to the dose rates, which were determined by a simplified calculation model. For small tissues for which the reduction of variances are difficult, the equivalent dose ratios to a larger tissue (with lower statistical errors) nearby were employed to make the calculation efficient. Empirical response functions relating photon energies, and the organ equivalent doses or the effective doses were then derived by the use of cubic-spline fitting of the resulting doses for 26 energy points. The DCFs for all radionuclides considered important were evaluated by combining the photon emission data of the radionuclide and the empirical response functions. Finally, contributions of accompanied beta particles to the skin equivalent doses and the effective doses were calculated separately and added to the DCFs. For radionuclides considered in this study, the new DCFs for the three exposure settings were within ±10 % when compared with DCFs in FGR 13.

  18. Effect of radiation dose rate and cyclophosphamide on pulmonary toxicity after total body irradiation in a mouse model

    International Nuclear Information System (INIS)

    Safwat, Akmal; Nielsen, Ole S.; El-Badawy, Samy; Overgaard, Jens

    1996-01-01

    Purpose: Interstitial pneumonitis (IP) is still a major complication after total body irradiation (TBI) and bone marrow transplantation (BMT). It is difficult to determine the exact role of radiation in this multifactorial complication, especially because most of the experimental work on lung damage was done using localized lung irradiation and not TBI. We have thus tested the effect of radiation dose rate and combining cyclophosphamide (CTX) with single fraction TBI on lung damage in a mouse model for BMT. Methods and Materials: TBI was given as a single fraction at a high dose rate (HDR, 0.71 Gy/min) or a low dose rate (LDR, 0.08 Gy/min). CTX (250 mg/kg) was given 24 h before TBI. Bone marrow transplantation (BMT) was performed 4-6 h after the last treatment. Lung damage was assessed using ventilation rate (VR) and lethality between 28 and 180 days (LD (50(28))-180 ). Results: The LD 50 for lung damage, ± standard error (SE), increased from 12.0 (± 0.2) Gy using single fraction HDR to 15.8 (± 0.6) Gy using LDR. Adding CTX shifted the dose-response curves towards lower doses. The LD 50 values for the combined treatment were 5.3 (± 0.2) and 3.5 (± 0.2) Gy for HDR and LDR, respectively. This indicates that the combined effect of CTX and LDR was more toxic than that of combined CTX and HDR. Lung damage evaluated by VR demonstrated two waves of VR increase. The first wave of VR increase occurred after 6 weeks using TBI only and after 3 weeks in the combined CTX-TBI treatment, irrespective of total dose or dose rate. The second wave of VR elevation resembled the IP that follows localized thoracic irradiation in its time of occurrence. Conclusions: Lung damage following TBI could be spared using LDR. However, CTX markedly enhances TBI-induced lung damage. The combination of CTX and LDR is more toxic to the lungs than combining CTX and HDR

  19. Relationship between chromosomal aberration of bone marrow cells and dosage of irradiation after 46Sc internal pollution and external low dose X-irradiation in mice

    International Nuclear Information System (INIS)

    Li Guofu; Li Zhang; Wu Yin

    1989-01-01

    The relationship between chromosomal aberration of bone marrow cells and dosage in mice 24 h after 46 Sc internal pollution combined with external low dose whole body X-irradiation was quantiatively studied. The results showed that the relationship between chromosomal aberration and dosage was expressed in a linear regression equation. The chromosomal aberration rate was lower in the combined exposure than that of the sum of internal and external exposures, but higher than that of either the internal or external exposure singly. The relationship between chromosomal aberration and time was expressed in the following three phase exponential function: Y(t) = 2.9078 exp 0.27668t + 2.9371 exp -0.0778t + 2.3786 -0.01788t . By means of fit test, there was no significant difference between the determined and the theoretical values. The 90% theoretical values got from all the equations distributed over the determined values

  20. Low-dose dual-energy cone-beam CT using a total-variation minimization algorithm

    International Nuclear Information System (INIS)

    Min, Jong Hwan

    2011-02-01

    Dual-energy cone-beam CT is an important imaging modality in diagnostic applications, and may also find its use in other application such as therapeutic image guidance. Despite of its clinical values, relatively high radiation dose of dual-energy scan may pose a challenge to its wide use. In this work, we investigated a low-dose, pre-reconstruction type of dual-energy cone-beam CT (CBCT) using a total-variation minimization algorithm for image reconstruction. An empirical dual-energy calibration method was used to prepare material-specific projection data. Raw data at high and low tube voltages are converted into a set of basis functions which can be linearly combined to produce material-specific data using the coefficients obtained through the calibration process. From much fewer views than are conventionally used, material specific images are reconstructed by use of the total-variation minimization algorithm. An experimental study was performed to demonstrate the feasibility of the proposed method using a micro-CT system. We have reconstructed images of the phantoms from only 90 projections acquired at tube voltages of 40 kVp and 90 kVp each. Aluminum-only and acryl-only images were successfully decomposed. We evaluated the quality of the reconstructed images by use of contrast-to-noise ratio and detectability. A low-dose dual-energy CBCT can be realized via the proposed method by greatly reducing the number of projections

  1. Compendium of Single Event Effects, Total Ionizing Dose, and Displacement Damage for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    LaBel, Kenneth A.; OBryan, Martha V.; Chen, Dakai; Campola, Michael J.; Casey, Megan C.; Pellish, Jonathan A.; Lauenstein, Jean-Marie; Wilcox, Edward P.; Topper, Alyson D.; Ladbury, Raymond L.; hide

    2014-01-01

    We present results and analysis investigating the effects of radiation on a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects (SEE), proton-induced displacement damage (DD), and total ionizing dose (TID). Introduction: This paper is a summary of test results.NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment is often limited by its susceptibility to single event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is quite difficult. Given the rapidly changing nature of technology, radiation test data are most often application-specific and adequate understanding of the test conditions is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transient (SET), TID, enhanced low dose rate sensitivity (ELDRS), and DD effects.

  2. Nuclear Enterprises portable dose rate meter type PDR4 and external probes types BP1/1, BP8 and GP9

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-08-01

    The performance characteristics of Nuclear Enterprises Portable Dose Rate Meter Type PDR4 are evaluated under the headings: general description, facilities and controls, radiation characteristics, electrical characteristics, environmental characteristics, mechanical characteristics, the manual, summary of performance, and conclusions. Results of an investigation of the radiation characteristics of the external probes Type BP1/1, Type BP8, and Type GP9 are also detailed. (U.K.)

  3. Determination of solid surface composition by the X-ray fluorescence method under total external reflection with angular scanning

    International Nuclear Information System (INIS)

    Krasnolutskij, V.P.

    2000-01-01

    Possibilities of determination of composition of surface layers by X-ray fluorescence analysis under total reflection of incident radiation with angular scanning of a target are investigated. For the case of the GaAs target it is shown that the sensibility of this method is sufficient for a control of element composition in layer of thickness 1 nm. A simple method for solution of inverse task of analysis of a two component medium is considered [ru

  4. Dose-effect relationship for cataract induction after single-dose total body irradiation and bone marrow transplantation for acute leukemia

    International Nuclear Information System (INIS)

    Kempen-Harteveld, M. Loes van; Belkacemi, Yazid; Kal, Henk B.; Labopin, Myriam; Frassoni, Francesco

    2002-01-01

    Purpose: To determine a dose-effect relationship for cataract induction, the tissue-specific parameter, α/β, and the rate of repair of sublethal damage, μ value, in the linear-quadratic formula have to be known. To obtain these parameters for the human eye lens, a large series of patients treated with different doses and dose rates is required. The data of patients with acute leukemia treated with single-dose total body irradiation (STBI) and bone marrow transplantation (BMT) collected by the European Group for Blood and Marrow Transplantation were an