WorldWideScience

Sample records for total direct radiative

  1. Correlation of total, diffuse, and direct solar radiation

    Science.gov (United States)

    Buyco, E. H.; Namkoong, D.

    1977-01-01

    Present requirements for realistic solar energy system evaluations necessitate a comprehensive body of solar-radition data. The data should include both diffuse and direct solar radiation as well as their total on an hourly (or shorter) basis. In general, however, only the total solar radiation values were recorded. This report presents a correlation that relates the diffuse component of an hourly total solar radiation value to the total radiation ratio of the maximum value attainable. The data used were taken at the Blue Hill Observatory in Milton, Massachusetts, for the period 1952. The relation - in the form of the data plots - can be used in situations in which only the hourly total radiation data are available but the diffuse component is desired.

  2. Synchrotron radiation total reflection for rainwater analysis

    International Nuclear Information System (INIS)

    Simabuco, Silvana M.; Matsumoto, Edson

    1999-01-01

    Total reflection X-ray fluorescence analysis excited with synchrotron radiation (SR-TXRF) has been used for rainwater trace element analysis. The samples were collected in four different sites at Campinas City, SP. Standard solutions with gallium as internal standard were prepared for the calibration system. Rainwater samples of 10 μl were putted onto Perspex reflector disk, dried on vacuum and analyzed for 100 s measuring time. The detection limits obtained for K-shell varied from 29 ng.ml -1 for sulfur to 1.3 ng.ml -1 for zinc and copper, while for L-shell the values were 4.5 ng.ml -1 for mercury and 7.0 ng.ml -1 for lead. (author)

  3. Spatially Refined Aerosol Direct Radiative Forcing Efficiencies

    Science.gov (United States)

    Global aerosol direct radiative forcing (DRF) is an important metric for assessing potential climate impacts of future emissions changes. However, the radiative consequences of emissions perturbations are not readily quantified nor well understood at the level of detail necessary...

  4. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1991-12-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facilities throughout the country for the third quarter of 1991

  5. Future directions in radiation oncology

    International Nuclear Information System (INIS)

    Peters, L.

    1996-01-01

    Full text: Cancer treatment has evolved progressively over the years as a joint result of improvements in technology and better understanding of the biological responses of neoplastic and normal cells to cytotoxic agents. Although major therapeutic 'breakthroughs' are unlikely absent the discovery of exploitable fundamental differences between cancer cells and their normal homologs, further incremental improvements in cancer treatment results can confidently be expected as we apply existing knowledge better and take advantage of new research insights. Areas in which I can foresee significant improvements (in approximate chronological order) are as follows: better physical radiation dose distributions; more effective radiation and chemoradiation protocols based on radiobiological principles; more rational use of radiation adjuvants based on biologic criteria; use of novel targets and vectors for systemic radionuclide therapy; use of genetic markers of radiosensitivity to determine radiation dose tolerances; and use of radiation as a modulator of therapeutic gene expression. Radiation research has contributed greatly to the efficacy of radiation oncology as it is now practised but has even greater potential for the future

  6. Effects of total dose of ionizing radiation on integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marcilei A.G.; Cirne, K.H.; Gimenez, S.; Santos, R.B.B. [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil); Added, N.; Barbosa, M.D.L.; Medina, N.H.; Tabacniks, M.H. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Lima, J.A. de; Seixas Junior, L.E.; Melo, W. [Centro de Tecnologia da Informacao Paulo Archer, Sao Paulo, SP (Brazil)

    2011-07-01

    Full text: The study of ionizing radiation effects on materials used in electronic devices is of great relevance for the progress of global technological development and, particularly, it is a necessity in some strategic areas in Brazil. Electronic circuits are strongly influenced by radiation and the need for IC's featuring radiation hardness is largely growing to meet the stringent environment in space electronics. On the other hand, aerospace agencies are encouraging both scientific community and semiconductors industry to develop hardened-by-design components using standard manufacturing processes to achieve maximum performance, while significantly reducing costs. To understand the physical phenomena responsible for changes in devices exposed to ionizing radiation several kinds of radiation should then be considered, among them alpha particles, protons, gamma and X-rays. Radiation effects on the integrated circuits are usually divided into two categories: total ionizing dose (TID), a cumulative dose that shifts the threshold voltage and increases transistor's off-state current; single events effects (SEE), a transient effect which can deposit charge directly into the device and disturb the properties of electronic circuits. TID is one of the most common effects and may generate degradation in some parameters of the CMOS electronic devices, such as the threshold voltage oscillation, increase of the sub-threshold slope and increase of the off-state current. The effects of ionizing radiation are the creation of electron-hole pairs in the oxide layer changing operation mode parameters of the electronic device. Indirectly, there will be also changes in the device due to the formation of secondary electrons from the interaction of electromagnetic radiation with the material, since the charge carriers can be trapped both in the oxide layer and in the interface with the oxide. In this work we have investigated the behavior of MOSFET devices fabricated with

  7. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.

    1994-03-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1993. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program

  8. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1993-03-01

    This report present the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1992. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program

  9. Total spectral distributions from Hawking radiation

    Energy Technology Data Exchange (ETDEWEB)

    Broda, Boguslaw [University of Lodz, Department of Theoretical Physics, Faculty of Physics and Applied Informatics, Lodz (Poland)

    2017-11-15

    Taking into account the time dependence of the Hawking temperature and finite evaporation time of the black hole, the total spectral distributions of the radiant energy and of the number of particles have been explicitly calculated and compared to their temporary (initial) blackbody counterparts (spectral exitances). (orig.)

  10. Directions in Radiation Transport Modelling

    Directory of Open Access Journals (Sweden)

    P Nicholas Smith

    2016-12-01

    More exciting advances are on the horizon to increase the power of simulation tools. The advent of high performance computers is allowing bigger, higher fidelity models to be created, if the challenges of parallelization and memory management can be met. 3D whole core transport modelling is becoming possible. Uncertainty quantification is improving with large benefits to be gained from more accurate, less pessimistic estimates of uncertainty. Advanced graphical displays allow the user to assimilate and make sense of the vast amounts of data produced by modern modelling tools. Numerical solvers are being developed that use goal-based adaptivity to adjust the nodalisation of the system to provide the optimum scheme to achieve the user requested accuracy on the results, thus removing the need to perform costly convergence studies in space and angle etc. More use is being made of multi-physics methods in which radiation transport is coupled with other phenomena, such as thermal-hydraulics, structural response, fuel performance and/or chemistry in order to better understand their interplay in reactor cores.

  11. Direction selective structural-acoustic coupled radiator

    Science.gov (United States)

    Seo, Hee-Seon; Kim, Yang-Hann

    2005-04-01

    This paper presents a method of designing a structural-acoustic coupled radiator that can emit sound in the desired direction. The structural-acoustic coupled system is consisted of acoustic spaces and wall. The wall composes two plates and an opening, and the wall separates one space that is highly reverberant and the other that is unbounded without any reflection. An equation is developed that predicts energy distribution and energy flow in the two spaces separated by the wall, and its computational examples are presented including near field acoustic characteristics. To design the directional coupled radiator, Pareto optimization method is adapted. An objective is selected to maximize radiation power on a main axis and minimize a side lobe level and a subjective is selected direction of the main axis and dimensions of the walls geometry. Pressure and intensity distribution of the designed radiator is also presented.

  12. Determination of radiation direction in environmental monitoring

    International Nuclear Information System (INIS)

    Campos, Vicente de Paulo de; Moura, Eduardo S.; Rocha, Felicia D.G.; Manzoli, Jose Eduardo

    2009-01-01

    The assessment of environmental exposure has been performed in Brazil using the thermoluminescence technique at Thermoluminescence Dosimetry Laboratory (LDT), at Nuclear and Energetic Research Institute (IPEN/CNEN-SP). To carry out these measurements, several thermoluminescent dosimeters (TLD's) were used to measure the expose. In this procedure, very few information of direction where the radiation came from is available. A vague supposition about the direction from where the radiation came from could be inferred only by evaluation of multiple dosimeters displaced at entire region of monitoring, but this demand to much effort or sometimes become impractical for certain situations. In this work, a single device is used to provide information about the direction from where the radiation came through. This device is called directional dosimeter (DD). Using more than one DD it is possible to reduce the uncertainty of the measurements and determine the radiation source position. The DD basically consists of a regular solid with high effective atomic number, where one TLD is positioned at each face. The DD allows evaluating the environmental exposure and the direction of the radiation by a simple vector sum. At each face of the DD, it is associated an orthogonal vector, and modulus of this vector represents the correspond exposure measured by the TLD. The direction of the radiation source is the sum of these faces vectors. The prototype used in this work was a lead cube with six TLDs of CaSO 4 :Dy/Teflon. The TLDs have high sensibility and are already used in area, environmental and personal monitoring. The measurements had shown the correct environmental exposure and a good indication of the radiation direction. (author)

  13. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1992-06-01

    The US Nuclear Regulatory Commission (NRC) Direct Radiation Monitoring Network is operated by the NRC in cooperation with participating states to provide continuous measurement of the ambient radiation levels around licensed NRC facilities, primarily power reactors. Ambient radiation levels result from naturally occurring radionuclides present in the soil, cosmic radiation constantly bombarding the earth from outer space, and the contribution, if any, from the monitored facilities and other man-made sources. The Network is intended to measure radiation levels during routine facility operations and to establish background radiation levels used to assess the radiological impact of an unusual condition, such as an accident. This report presents the radiation levels measured around all facilities in the Network for the first quarter of 1992. All radiation measurements are made using small, passive detectors called thermoluminescent dosimeters (TLDs), which provide a quantitative measurement of the radiation levels in the area in which they are placed. Each site is monitored by arranging approximately 40 to 50 TLD stations in two concentric rings extending to about five miles from the facility. All TLD stations are outside the site boundary of the facility

  14. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1991-04-01

    This report presents the results of the NRC [Nuclear Regulatory Commission] Direct Radiation Monitoring Network for the fourth quarter of 1990. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program. 3 figs., 4 tabs

  15. Making Choices: Self-Directed Teams or Total Quality Management?

    Science.gov (United States)

    Holpp, Lawrence

    1992-01-01

    Describes differences between total quality management and self-directed teams in terms of job design, decision making, flexibility, supervision, labor relations, quality, customers, and training. Offers suggestions for which method to choose when. (SK)

  16. Direct cost comparison of totally endoscopic versus open ear surgery.

    Science.gov (United States)

    Patel, N; Mohammadi, A; Jufas, N

    2018-02-01

    Totally endoscopic ear surgery is a relatively new method for managing chronic ear disease. This study aimed to test the null hypothesis that open and endoscopic approaches have similar direct costs for the management of attic cholesteatoma, from an Australian private hospital setting. A retrospective direct cost comparison of totally endoscopic ear surgery and traditional canal wall up mastoidectomy for the management of attic cholesteatoma in a private tertiary setting was undertaken. Indirect and future costs were excluded. A direct cost comparison of anaesthetic setup and resources, operative setup and resources, and surgical time was performed between the two techniques. Totally endoscopic ear surgery has a mean direct cost reduction of AUD$2978.89 per operation from the hospital perspective, when compared to canal wall up mastoidectomy. Totally endoscopic ear surgery is more cost-effective, from an Australian private hospital perspective, than canal wall up mastoidectomy for attic cholesteatoma.

  17. Total Risk Management for Low Dose Radiation Exposures

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; Sterc, D.

    2012-01-01

    health. This view is supported with numerous evidences, and explained with beneficial effects from the increased activity of immune system activated with small radiation exposures. Finally, theory in between is that small doses are less than linearly proportionally harmful and that they are presenting a much smaller risks than according to the LNT. This view is derived from the use of different evidences. Difficulties to find one single theory about effects of small radiation doses are related to existence of huge variability and uncertainty in the evidence data. This is very hard experimental and theoretical problem. It will require lots of additional research to reduce these uncertainties and find final theory. This might be too late for the number of people affected in different ways with current single most conservative LNT approach. The problem with the conservative LNT regulatory approach is resulting in enormous additional costs of nuclear energy and medical applications. Which is reasonable and acceptable during the regular operation when source is high and concentrated. But, this becomes unreasonable huge economic burden after accidents and for cleanups with nuclear facilities. Similar problem arises with restriction of medical examinations and treatments based on over conservative risk estimate. Special circumstances are with evacuated people from contaminated areas where they are on the one side saved from small radiation exposures, and on the other side exposed to years of life away from their home and with numerous direct and indirect additional risks (i.e., stress, social problems, etc.). It seems reasonable that some alternative (total) risk management approach might be much more suitable for this situation. Evacuation of people from contaminated area with small doses sources should not be done when that induces larger risks from even what is expected from radiation based on LNT. Similar total risk management could be also applied for with medical

  18. French government to trim direct stake in Total

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that the French government has decided to slash its direct stake in partly state owned oil company Total to 5% from 31.7%, a surprise move expected to raise 10 billion francs ($1.8 billion). At the same time, other state owned entities will be asked to boost their combined 2.2% stake in Total to 10%, leaving the government with a net 15% interest in Total vs. the current 34%. Initially, state owned insurance companies Groupe des Assurances Nationales and Assurances Generale de France will be asked to hike their stakes in Total, but others could be asked to join if needed to meet the 10% target. The government the its phase-down of participation in Total, established in 1924 to manage French interests in Iraq Petroleum Co., was prompted by the evolution of the oil context, which differs greatly from what had prompted a significant stake of the state in Total's capital

  19. Directional sound radiation from substation transformers

    International Nuclear Information System (INIS)

    Maybee, N.

    2009-01-01

    This paper presented the results of a study in which acoustical measurements at two substations were analyzed to investigate the directional behaviour of typical arrays having 2 or 3 transformers. Substation transformers produce a characteristic humming sound that is caused primarily by vibration of the core at twice the frequency of the power supply. The humming noise radiates predominantly from the tank enclosing the core. The main components of the sound are harmonics of 120 Hz. Sound pressure level data were obtained for various directions and distances from the arrays, ranging from 0.5 m to over 100 m. The measured sound pressure levels of the transformer tones displayed substantial positive and negative excursions from the calculated average values for many distances and directions. The results support the concept that the directional effects are associated with constructive and destructive interference of tonal sound waves emanating from different parts of the array. Significant variations in the directional sound pattern can occur in the near field of a single transformer or an array, and the extent of the near field is significantly larger than the scale of the array. Based on typical dimensions for substation sites, the distance to the far field may be much beyond the substation boundary and beyond typical setbacks to the closest dwellings. As such, the directional sound radiation produced by transformer arrays introduces additional uncertainty in the prediction of substation sound levels at dwellings within a few hundred meters of a substation site. 4 refs., 4 figs.

  20. Near-term Forecasting of Solar Total and Direct Irradiance for Solar Energy Applications

    Science.gov (United States)

    Long, C. N.; Riihimaki, L. D.; Berg, L. K.

    2012-12-01

    Integration of solar renewable energy into the power grid, like wind energy, is hindered by the variable nature of the solar resource. One challenge of the integration problem for shorter time periods is the phenomenon of "ramping events" where the electrical output of the solar power system increases or decreases significantly and rapidly over periods of minutes or less. Advance warning, of even just a few minutes, allows power system operators to compensate for the ramping. However, the ability for short-term prediction on such local "point" scales is beyond the abilities of typical model-based weather forecasting. Use of surface-based solar radiation measurements has been recognized as a likely solution for providing input for near-term (5 to 30 minute) forecasts of solar energy availability and variability. However, it must be noted that while fixed-orientation photovoltaic panel systems use the total (global) downwelling solar radiation, tracking photovoltaic and solar concentrator systems use only the direct normal component of the solar radiation. Thus even accurate near-term forecasts of total solar radiation will under many circumstances include inherent inaccuracies with respect to tracking systems due to lack of information of the direct component of the solar radiation. We will present examples and statistical analyses of solar radiation partitioning showing the differences in the behavior of the total/direct radiation with respect to the near-term forecast issue. We will present an overview of the possibility of using a network of unique new commercially available total/diffuse radiometers in conjunction with a near-real-time adaptation of the Shortwave Radiative Flux Analysis methodology (Long and Ackerman, 2000; Long et al., 2006). The results are used, in conjunction with persistence and tendency forecast techniques, to provide more accurate near-term forecasts of cloudiness, and both total and direct normal solar irradiance availability and

  1. Precise estimation of total solar radiation on tilted surface

    African Journals Online (AJOL)

    rajeev

    rarely available required for precise sizing of energy systems. The total solar radiation at different orientation and slope is needed to calculate the efficiency of the installed solar energy systems. To calculate clearness index (Kt) used by Gueymard (2000) for estimating solar irradiation H, irradiation at the earth's surface has ...

  2. Total, Direct, and Indirect Effects in Logit Models

    DEFF Research Database (Denmark)

    Karlson, Kristian Bernt; Holm, Anders; Breen, Richard

    It has long been believed that the decomposition of the total effect of one variable on another into direct and indirect effects, while feasible in linear models, is not possible in non-linear probability models such as the logit and probit. In this paper we present a new and simple method...... average partial effects, as defined by Wooldridge (2002). We present the method graphically and illustrate it using the National Educational Longitudinal Study of 1988...

  3. Theoretic simulation for CMOS device on total dose radiation response

    International Nuclear Information System (INIS)

    He Baoping; Zhou Heqin; Guo Hongxia; He Chaohui; Zhou Hui; Luo Yinhong; Zhang Fengqi

    2006-01-01

    Total dose effect is simulated for C4007B, CC4007RH and CC4011 devices at different absorbed dose rate by using linear system theory. When irradiation response and dose are linear, total dose radiation and post-irradiation annealing at room temperature are determined for one random by choosing absorbed dose rate, and total dose effect at other absorbed dose rate can be predicted by using linear system theory. The simulating results agree with the experimental results at different absorbed dose rate. (authors)

  4. A sensor element for direct radiation measurement

    Energy Technology Data Exchange (ETDEWEB)

    Bajons, P.; Wernhart, U.; Zeiler, H. [University of Vienna (Austria). Institut of Material Physics

    1998-08-01

    A combination of a photodiode with a nonimaging light concentrator is developed to perform measurements of the direct solar radiation component. A prototype composed of low price elements is taken as a starting point to discuss the problems which must be faced when calibrating such sensors. By this the influence of the angle of incidence and spectral distribution (caused by different air mass or varying degree of clearness) of the incident radiation on the behavior of the system is studied. The readings are compared to the calculated (global minus diffuse) readings obtained from two standard star pyranometers. Finally the possibilities for increasing the accuracy of the sensor element and for applying the device are discussed. (author)

  5. Ascertaining directionality information from incident nuclear radiation

    Energy Technology Data Exchange (ETDEWEB)

    Archambault, Brian C. [Purdue University (United States); Lapinskas, Joseph R. [QSA Global, Inc. (United States); Wang Jing; Webster, Jeffrey A. [Purdue University (United States); McDeavitt, Sean [Texas A and M University (United States); Taleyarkhan, Rusi P., E-mail: rusi@purdue.edu [Purdue University (United States)

    2011-10-15

    Highlights: > Use of tensioned metastable fluids for detection of fast neutron radiation. > Monitored neutrons with 100% gamma photon blindness capability. > Monitored direction of incoming neutron radiation from special nuclear material emissions. > Ascertained directionality of neutron source to within 30 deg. and with 80% confidence with 2000 detection events at rate of 30-40 per second. > Conducted successful blind test for determining source of neutrons from a hidden neutron emitting source. > Compared results with MCNP5-COMSOL based multi-physics model. - Abstract: Unprecedented capabilities for the detection of nuclear particles via tailored resonant acoustic systems such as the acoustic tensioned metastable fluid detection (ATMFD) systems were assessed for determining directionality of incoming fast neutrons. This paper presents advancements that expand on these accomplishments, thereby increasing the accuracy and precision of ascertaining directionality information utilizing enhanced signal processing-cum-signal analysis, refined computational algorithms, and on demand enlargement of the detector sensitive volume. Advances in the development of ATMFD systems were accomplished utilizing a combination of experimentation and theoretical modeling. Modeling methodologies include Monte-Carlo based nuclear particle transport using MCNP5 and multi-physics based assessments accounting for acoustic, structural, and electromagnetic coupling of the ATMFD system via COMSOL's multi-physics simulation platform. Benchmarking and qualification studies have been conducted with a 1 Ci Pu-Be neutron-gamma source. These results show that the specific ATMFD system used for this study can enable detection of directionality of incoming fast neutrons from the neutron source to within 30{sup o} with 80% confidence; this required {approx}2000 detection events which could be collected within {approx}50 s at a detection rate of {approx}30-40 per second. Blind testing was

  6. Ascertaining directionality information from incident nuclear radiation

    International Nuclear Information System (INIS)

    Archambault, Brian C.; Lapinskas, Joseph R.; Wang Jing; Webster, Jeffrey A.; McDeavitt, Sean; Taleyarkhan, Rusi P.

    2011-01-01

    Highlights: → Use of tensioned metastable fluids for detection of fast neutron radiation. → Monitored neutrons with 100% gamma photon blindness capability. → Monitored direction of incoming neutron radiation from special nuclear material emissions. → Ascertained directionality of neutron source to within 30 deg. and with 80% confidence with 2000 detection events at rate of 30-40 per second. → Conducted successful blind test for determining source of neutrons from a hidden neutron emitting source. → Compared results with MCNP5-COMSOL based multi-physics model. - Abstract: Unprecedented capabilities for the detection of nuclear particles via tailored resonant acoustic systems such as the acoustic tensioned metastable fluid detection (ATMFD) systems were assessed for determining directionality of incoming fast neutrons. This paper presents advancements that expand on these accomplishments, thereby increasing the accuracy and precision of ascertaining directionality information utilizing enhanced signal processing-cum-signal analysis, refined computational algorithms, and on demand enlargement of the detector sensitive volume. Advances in the development of ATMFD systems were accomplished utilizing a combination of experimentation and theoretical modeling. Modeling methodologies include Monte-Carlo based nuclear particle transport using MCNP5 and multi-physics based assessments accounting for acoustic, structural, and electromagnetic coupling of the ATMFD system via COMSOL's multi-physics simulation platform. Benchmarking and qualification studies have been conducted with a 1 Ci Pu-Be neutron-gamma source. These results show that the specific ATMFD system used for this study can enable detection of directionality of incoming fast neutrons from the neutron source to within 30 o with 80% confidence; this required ∼2000 detection events which could be collected within ∼50 s at a detection rate of ∼30-40 per second. Blind testing was successfully

  7. Total, direct, and indirect effects of paan on oral cancer.

    Science.gov (United States)

    Merchant, Anwar T; Pitiphat, Waranuch

    2015-03-01

    Paan (betel leaf and betel nut quid) used with or without tobacco has been positively associated with oral cancer. Oral submucous fibrosis (OSMF), a precancerous condition caused by paan, lies on the causal pathway between paan use and oral cancer. The purpose of this analysis was to estimate the effect of paan consumption on oral cancer risk when it is mediated by OSMF. We used mediation methods proposed by VanderWeele, which are based on causal inference principles, to characterize the total, direct, and indirect effects of paan, consumed with and without tobacco, on oral cancer mediated by OSMF. We reanalyzed case-control data collected from three hospitals in Karachi, Pakistan, between July 1996 and March 1998. For paan without tobacco, the total effect on oral cancer was OR 7.39, 95 % CI 1.01, 38.11, the natural indirect effect (due to OSMF among paan users) was OR 2.48, 95 % CI 0.99, 10.44, and the natural direct effect (due to paan with OSMF absent) was OR 3.32, 95 % CI 0.68, 10.07. For paan with tobacco, the total direct effect was OR 15.68, 95 % CI 3.00, 54.90, the natural indirect effect was OR 2.18, 95 % CI 0.82, 5.52, and the natural direct effect was OR 7.27, 95 % CI 2.15, 20.43. Paan, whether or not it contained tobacco, raised oral cancer risk irrespective of OSMF. Oral cancer risk was higher among those who used paan with tobacco.

  8. A general method for computing the total solar radiation force on complex spacecraft structures

    Science.gov (United States)

    Chan, F. K.

    1981-01-01

    The method circumvents many of the existing difficulties in computational logic presently encountered in the direct analytical or numerical evaluation of the appropriate surface integral. It may be applied to complex spacecraft structures for computing the total force arising from either specular or diffuse reflection or even from non-Lambertian reflection and re-radiation.

  9. Direct analysis of quantal radiation response data

    International Nuclear Information System (INIS)

    Thames, H.D. Jr.; Rozell, M.E.; Tucker, S.L.; Ang, K.K.; Travis, E.L.; Fisher, D.R.

    1986-01-01

    A direct analysis is proposed for quantal (all-or-nothing) responses to fractionated radiation and endpoint-dilution assays of cell survival. As opposed to two-step methods such as the reciprocal-dose technique, in which ED 50 values are first estimated for different fractionation schemes and then fit (as reciprocals) against dose per fraction, all raw data are included in a single maximum-likelihood treatment. The method accommodates variations such as short-interval fractionation regimens designed to determine tissue repair kinetics, tissue response to continuous exposures, and data obtained using endpoint-dilution assays of cell survival after fractionated doses. Monte-Carlo techniques were used to compare the direct and reciprocal-dose methods for analysis of small-scale and large-scale studies of response to fractionated doses. Both methods tended toward biased estimates in the analysis of small-scale (3 fraction numbers) studies. The α/β ratios showed less scatter when estimated by the direct method. The 95% confidence intervals determined by the direct method were more appropriate than those determined by reciprocal-dose analysis, for which 18% (small-scale study) or 8% (large-scale study) of the confidence intervals did not include the 'true' value of α/β. (author)

  10. Photometric estimation of defect size in radiation direction

    International Nuclear Information System (INIS)

    Zuev, V.M.

    1993-01-01

    Factors, affecting accuracy of photometric estimation of defect size in radiation transmission direction, are analyzed. Experimentally obtained dependences of contrast of defect image on its size in radiation transmission direction are presented. Practical recommendations on improving accuracy of photometric estimation of defect size in radiation transmission direction, are developed

  11. Radiation Modeling with Direct Simulation Monte Carlo

    Science.gov (United States)

    Carlson, Ann B.; Hassan, H. A.

    1991-01-01

    Improvements in the modeling of radiation in low density shock waves with direct simulation Monte Carlo (DSMC) are the subject of this study. A new scheme to determine the relaxation collision numbers for excitation of electronic states is proposed. This scheme attempts to move the DSMC programs toward a more detailed modeling of the physics and more reliance on available rate data. The new method is compared with the current modeling technique and both techniques are compared with available experimental data. The differences in the results are evaluated. The test case is based on experimental measurements from the AVCO-Everett Research Laboratory electric arc-driven shock tube of a normal shock wave in air at 10 km/s and .1 Torr. The new method agrees with the available data as well as the results from the earlier scheme and is more easily extrapolated to di erent ow conditions.

  12. Total and available metal contents in sediments by synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Moreira, Silvana; Sobrinho, Gilmar A.; Jesus, Edgar F.O. de; Lopes, Ricardo T.

    2002-01-01

    In this work the total and available contents of Al, Si, Cl, K, Mn, Fe, Co, Ni, Cu, Zn, Sr, Zr, Ba, Ce and Pb in sediments from river Atibaia were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence technique. The detection limits for K series varies from 200 ng.mL -1 for Al to 2 ng.mL -1 for Zn while for L series the value varies from 20 ng.mL -1 for Ba to 10 ng.mL -1 for Pb. The samples were submitted to two different processes, in order to obtain the total and biological available metal contents. The information about metal content is a important parameter for a correct evaluation about the hydrologic cycle in Piracicaba basin. All the measure were carried out at the National Synchrotron Light Laboratory, Campinas, SP, Brazil, using a white beam for excitation. (author)

  13. Ultraviolet radiation and air contamination during total hip replacement

    International Nuclear Information System (INIS)

    Carlsson, A.S.; Nilsson, B.; Walder, M.H.; Osterberg, K.

    1986-01-01

    Ultraviolet (uv) radiation of the operating room was assessed bacteriologically in an open randomized study of 30 total hip procedures. Volumetric air-sampling demonstrated that the number of colony forming units (cfu m-3) were significantly reduced (P less than 0.001) by uv light, both close to the wound and in the periphery of the operating room. No adverse effects of the uv-irradiation were observed either in the patients or the staff. In operating rooms fitted with a zonal ventilation system and with an air change rate of about 70 h-1, the addition of uv irradiation during surgery may achieve ultra clean air. However, in conventionally ventilated operating rooms uv-irradiation alone is probably not sufficient to do so

  14. 21 CFR 862.1110 - Bilirubin (total or direct) test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bilirubin (total or direct) test system. 862.1110... Systems § 862.1110 Bilirubin (total or direct) test system. (a) Identification. A bilirubin (total or direct) test system is a device intended to measure the levels of bilirubin (total or direct) in plasma...

  15. Radiation Metabolomics: Current Status and Future Directions

    Directory of Open Access Journals (Sweden)

    Smrithi eSugumaran Menon

    2016-02-01

    Full Text Available Human exposure to ionizing radiation disrupts normal metabolic processes in cells and organs by inducing complex biological responses that interfere with gene and protein expression. Conventional dosimetry, monitoring of prodromal symptoms and peripheral lymphocyte counts are of limited value as organ and tissue specific biomarkers for personnel exposed to radiation, particularly, weeks or months after exposure. Analysis of metabolites generated in known stress-responsive pathways by molecular profiling helps to predict the physiological status of an individual in response to environmental or genetic perturbations. Thus, a multi-metabolite profile obtained from a high resolution mass spectrometry-based metabolomics platform offers potential for identification of robust biomarkers to predict radiation toxicity of organs and tissues resulting from exposures to therapeutic or non-therapeutic ionizing radiation. Here, we review the status of radiation metabolomics and explore applications as a standalone technology, as well as its integration in systems biology, to facilitate a better understanding of the molecular basis of radiation response. Finally, we draw attention to the identification of specific pathways that can be targeted for the development of therapeutics to alleviate or mitigate harmful effects of radiation exposure.

  16. Directional Total Generalized Variation Regularization for Impulse Noise Removal

    DEFF Research Database (Denmark)

    Kongskov, Rasmus Dalgas; Dong, Yiqiu

    2017-01-01

    this regularizer for directional images is highly advantageous. In order to estimate directions in impulse noise corrupted images, which is much more challenging compared to Gaussian noise corrupted images, we introduce a new Fourier transform-based method. Numerical experiments show that this method is more...

  17. Directional Radiation Dosimeter for Area and Environmental Monitoring

    International Nuclear Information System (INIS)

    Manzoli, J.E.; Campos, V.P.; Moura, E.S.

    2009-01-01

    It is presented a dosimeter that is able to measure the photon exposure and the direction from where the radiation came from. Preliminary measurements performed by this new directional radiation dosimeter demonstrate its application. This dosimeter consists of a small lead cube with thermoluminescent discs on each face, placed in well known coordinates. Only one dosimeter of this kind indicates the direction of the radiation beam, if it came from a unique position. This study was conducted inside the radiation room of a Cobalt-60 Gamma Irradiator and the dosimeter indicated the source position

  18. Radiation Chemistry of Polyethylenes for Total Joint Applications

    International Nuclear Information System (INIS)

    Muratoglu, O.K.

    2006-01-01

    Wear and fatigue damage of polyethylene could limit the longevity of total hip and knee reconstructions used to treat end-stage joint diseases. Wear debris causes peri-prosthetic osteolysis, resulting in bone loss and component loosening ultimately necessitating revision surgery. Wear rate of polyethylene can be reduced by radiation crosslinking. Irradiation not only crosslinks the amorphous phase of polyethylene but also creates residual free radicals (RFR), the precursor to long-term oxidation. We used post-irradiation melting to eliminate the RFRs and improve oxidative stability. We determined the molecular weight between crosslinks (M c ) as a function of radiation-dose level and showed the wear rate to scale linearly with M c . Irradiated and melted polyethylene, in clinical use since 1998, show a significant reduction in wear in vivo through radiographic follow-up studies and analysis of surgically explanted acetabular liners. Irradiation and melting reduces the crystallinity and mechanical properties of polyethylene therefore it cannot be used for high demand joint applications, such as posterior stabilized knees. We replaced the post-irradiation melting step with ?-tocopherol (vitamin-E) doping to stabilize the RFRs and prevent long-term stability and at the same time prevent the loss of mechanical properties. 100kGy irradiated polyethylene was soaked in 120 degree vitamin-E followed by a homogenization step at 120degree. The ?-tocopherol doped samples showed no detectable oxidation after accelerating aging at 80degree in air for 5 weeks. The wear rate was comparable to that of 100-kGy irradiated and melted polyethylene with both clean and third body added bovine serum lubrication. The fatigue strength of ?-tocopherol doped polyethylene (ΔKi=0.9MPa.m 1 /2) were higher than that of 100-kGy irradiated and melted polyethylene (ΔKi=0.5 MPa.m 1 /2). Similarly, the ultimate tensile and yield strength of α-tocopherol doped polyethylenes were significantly

  19. Direct and indirect effects of radiation on polar solid solutions

    International Nuclear Information System (INIS)

    Ershov, V.G.; Gaponova, I.S.

    1982-01-01

    Radiation-chemical decomposition of a solute is due to the direct effect of ionizing radiation on it and also to its reaction with radical-ion products of radiolysis of the solution. At low temperature, the movement of the reagents is limited, and thus it is possible to isolate and evaluate the contribution of direct and indirect effects of radiation on the solute. The present paper is devoted to an investigation of the mechanism of formation of radicals from a solute (LiNO 2 ) in a polar solid solution (CH 3 OH) under the effect of γ-radiation

  20. Secondary radiation dose during high-energy total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Janiszewska, M.; Raczkowski, M. [Lower Silesian Oncology Center, Medical Physics Department, Wroclaw (Poland); Polaczek-Grelik, K. [University of Silesia, Medical Physics Department, Katowice (Poland); Szafron, B.; Konefal, A.; Zipper, W. [University of Silesia, Department of Nuclear Physics and Its Applications, Katowice (Poland)

    2014-05-15

    The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: {sup 56}Mn in the stainless steel and {sup 187}W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 μSv from activated radionuclides. Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once. (orig.) [German] Die zusaetzliche Dosis durch sekundaere Neutronen- und γ-Strahlung waehrend der Ganzkoerperbestrahlung mit Roentgenstrahlung aus medizinischen Linearbeschleunigern wurde abgeschaetzt. Bei der Emission hochenergetischer Strahlen zur Teletherapie finden hauptsaechlich im Beschleuniger

  1. Micro-CT image reconstruction based on alternating direction augmented Lagrangian method and total variation.

    Science.gov (United States)

    Gopi, Varun P; Palanisamy, P; Wahid, Khan A; Babyn, Paul; Cooper, David

    2013-01-01

    Micro-computed tomography (micro-CT) plays an important role in pre-clinical imaging. The radiation from micro-CT can result in excess radiation exposure to the specimen under test, hence the reduction of radiation from micro-CT is essential. The proposed research focused on analyzing and testing an alternating direction augmented Lagrangian (ADAL) algorithm to recover images from random projections using total variation (TV) regularization. The use of TV regularization in compressed sensing problems makes the recovered image quality sharper by preserving the edges or boundaries more accurately. In this work TV regularization problem is addressed by ADAL which is a variant of the classic augmented Lagrangian method for structured optimization. The per-iteration computational complexity of the algorithm is two fast Fourier transforms, two matrix vector multiplications and a linear time shrinkage operation. Comparison of experimental results indicate that the proposed algorithm is stable, efficient and competitive with the existing algorithms for solving TV regularization problems. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. The objectives of the directive on radiation protection for patients

    International Nuclear Information System (INIS)

    Courades, J.M.

    1992-01-01

    Improvement of the quality of medical uses of radiation and avoiding unnecessary exposure are the main objectives of the 1984 Directive laying down basic measures for the radiation protection of persons undergoing medical examination or treatment. This paper explains how these goals have been achieved through the implementation of the various provisions of the Community act since its adoption

  3. The objectives of the Directive on radiation protection for patients

    International Nuclear Information System (INIS)

    Courades, J.M.

    1992-01-01

    Improvement of the quality of medical uses of radiation and avoiding unnecessary exposure are the main objectives of the 1984 Directive laying down basic measures for the radiation protection of persons undergoing medical examination or treatment. This paper explains how these goals have been achieved through the implementation of the various provisions of the Community act since its adoption. (author)

  4. Efficient Radiation Shielding Through Direct Metal Laser Sintering

    Data.gov (United States)

    National Aeronautics and Space Administration — We have developed a method for efficient component-level radiation shielding that can be printed by direct metal laser sintering (DMLS) from files generated by the...

  5. Radiation protection office at the general direction of health

    International Nuclear Information System (INIS)

    Piechowski, J.

    1996-01-01

    The radiation protection office at the general direction of health has the following functions: organisation and relations with decentralized services, legal aspects, relations with the direction of nuclear installation safety, nuclear medicine with licensing, radioactive wastes in relation with ANDRA, environment, trusteeship of OPRI in matter of measurements, dosimetry and epidemiology in relation with the Minister of work and training in radiation protection. (N.C.)

  6. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  7. Direct conversion of nuclear energy into radiation: New direction in thermonuclear laser fusion

    International Nuclear Information System (INIS)

    Babaev, Yu.N.; Vedenov, A.A.; Filyukov, A.A.

    1995-01-01

    In investigations dealing with thermonuclear fusion, a radical new direction appeared some time ago, namely the direct conversion of nuclear and thermonuclear energy into radiation energy. This paper reviews early work on this topic in Russia and the United States and discusses some recent new directions

  8. Indirect detection of radiation sources through direct detection of radiolysis products

    Science.gov (United States)

    Farmer, Joseph C [Tracy, CA; Fischer, Larry E [Los Gatos, CA; Felter, Thomas E [Livermore, CA

    2010-04-20

    A system for indirectly detecting a radiation source by directly detecting radiolytic products. The radiation source emits radiation and the radiation produces the radiolytic products. A fluid is positioned to receive the radiation from the radiation source. When the fluid is irradiated, radiolytic products are produced. By directly detecting the radiolytic products, the radiation source is detected.

  9. Multi-directional radiation detector using photographic film

    International Nuclear Information System (INIS)

    Junet, L K; Majid, Z A Abdul; Sapuan, A H; Sayed, I S; Pauzi, N F

    2014-01-01

    Ionising radiation has always been part of our surrounding and people are continuously exposed to it. Ionising radiation is harmful to human health, thus it is vital to monitor the radiation. To monitor radiation, there are three main points that should be observed cautiously, which are energy, quantity, and direction of the radiation sources. A three dimensional (3D) dosimeter is an example of a radiation detector that provide these three main points. This dosimeter is able to record the radiation dose distribution in 3D. Applying the concept of dose detection distribution, study has been done to design a multi-directional radiation detector of different filter thicknesses. This is obtained by designing a cylinder shaped aluminum filter with several layers of different thickness. Black and white photographic material is used as a radiation-sensitive material and a PVC material has been used as the enclosure. The device is then exposed to a radiation source with different exposure factors. For exposure factor 70 kVp, 16 mAs; the results have shown that optical density (OD) value at 135° is 1.86 higher compared with an OD value at 315° which is 0.71 as the 135° area received more radiation compare to 315° region. Furthermore, with an evidence of different angle of film give different value of OD shows that this device has a multidirectional ability. Materials used to develop this device are widely available in the market, thus reducing the cost of development and making it suitable for commercialisation

  10. Fractal characteristics correlation between the solar total radiation and net radiation on the apple tree canopy

    International Nuclear Information System (INIS)

    Meng Ping; Zhang Jingsong

    2005-01-01

    The characteristics correlation between solar total radiations(Q) and net radiation(R n) on the apple tree canopy at mainly growth stage in the hilly of Taihang Mountain are analyzed with fractal theory based on regression analysis. The results showed that:1)Q and R n had good liner correlation. The regression function was as the following:R n=0.740 8Q-32.436, which coefficient r is 0.981 1(n=26 279), F cal= 343 665.2 F 0.01 36 277=6.63; 2)The fractal dimension curves of Q and R n both had two no s caling regions, which circumscription time value of the inflexion was 453 and 441 minutes respectively.In the first region, fractal dimensions of Q and R n was 1.112 6, 1.131 9 respectively,and 1.913 6@@@ 1.883 4 in the second region.Those information showed that fractal characteristics of Q and R n is similar. So R n can be calculated with Q on the apple tree canopy

  11. Direct radiative effect due to brownness in organic carbon aerosols generated from biomass combustion

    International Nuclear Information System (INIS)

    Rathod, T.D.; Sahu, S.K.; Tiwari, M.; Pandit, G.G.

    2016-01-01

    We report the enhancement in the direct radiative effect due the presence of Brown carbon (BrC) as a part of organic carbon aerosols. The optical properties of organic carbon aerosols generated from pyrolytic combustion of mango tree wood (Magnifera Indica) and dung cake at different temperatures were considered. Mie codes were used to calculate absorption and scattering coefficients coupled with experimentally derived imaginary complex refractive index. The direct radiative effect (DRE) for sampled organic carbon aerosols was estimated using a wavelength dependent radiative transfer equation. The BrC DRE was estimated taking virtually non absorbing organic aerosols as reference. The BrC DRE from wood and dung cake was compared at different combustion temperatures and conditions. The BrC contributed positively to the direct top of the atmosphere radiative effect. Dung cake generated BrC aerosols were found to be strongly light absorbing as compared to BrC from wood combustion. It was noted that radiative effects of BrC from wood depended on its generation temperature and conditions. For BrC aerosols from dung cake such strong dependence was not observed. The average BrC aerosol DRE values were 1.53±0.76 W g"−"1 and 17.84±6.45 W g"−"1 for wood and dung cake respectively. The DRE contribution of BrC aerosols came mainly (67–90%) from visible light absorption though they exhibited strong absorption in shorter wavelengths of the UV–visible spectrum. - Highlights: • Biomass fuels (wood and dung cake) were studied for brown carbon direct radiative effects. • Model calculations predicted positive contribution of Brown carbon aerosols to organic carbon direct radiative effect. • Average direct radiative values for brown carbon from dung cake were higher compare to wood. • The visible light absorption played major role in brown carbon contribution (67–90 %) to total direct radiative effect.

  12. Assembly of gamma radiation detection with directivity properties

    International Nuclear Information System (INIS)

    Stoica, M.; Talpalariu, C.

    2016-01-01

    An assembly of gamma radiation detection with directivity properties and small size enables the development of portable equipment or robots specialized in finding and signaling radioactively contaminated areas in case of nuclear incidents or decommissioning of nuclear installations. Directivity characteristic of the assembly of gamma radiation detection is very important when aiming to build an equipment for searching radioactively contaminated areas. In order to obtain a suitable directivity characteristics in terms of detection of gamma rays, it was necessary to construct a lead collimator with a cylindrical shape. The detector, preamplifier and amplifier pulse were placed inside the collimator and pulse discriminator circuit and power source were placed beside the collimator, all being disposed within the housing cylindrical experimental. A PIN photodiode type was used as a detector of gamma radiation. (authors)

  13. Total and Differential Efficiencies for a Circular Detector Viewing a Circular Radiator of Finite Thickness

    Energy Technology Data Exchange (ETDEWEB)

    Lauber, A; Tollander, B

    1967-08-15

    Total and differential detection efficiencies have been computed for a circular detector viewing a circular radiator of finite thickness. Isotropic, cosines and n-p scattering angular emission distributions of the radiated particles are considered. Tables are given for the total efficiencies as well as for the differential efficiencies in the n-p scattering case.

  14. Effects of flow gradients on directional radiation of human voice.

    Science.gov (United States)

    Pulkki, Ville; Lähivaara, Timo; Huhtakallio, Ilkka

    2018-02-01

    In voice communication in windy outdoor conditions, complex velocity gradients appear in the flow field around the source, the receiver, and also in the atmosphere. It is commonly known that voice emanates stronger towards the downstream direction when compared with the upstream direction. In literature, the atmospheric effects are used to explain the stronger emanation in the downstream direction. This work shows that the wind also has an effect to the directivity of voice also favouring the downstream direction. The effect is addressed by measurements and simulations. Laboratory measurements are conducted by using a large pendulum with a loudspeaker mimicking the human head, whereas practical measurements utilizing the human voice are realized by placing a subject through the roof window of a moving car. The measurements and a simulation indicate congruent results in the speech frequency range: When the source faces the downstream direction, stronger radiation coinciding with the wind direction is observed, and when it faces the upstream direction, radiation is not affected notably. The simulated flow gradients show a wake region in the downstream direction, and the simulated acoustic field in the flow show that the region causes a wave-guide effect focusing the sound in the direction.

  15. The total ozone and UV solar radiation over Stara Zagora, Bulgaria

    Science.gov (United States)

    Mendeva, B. D.; Gogosheva, Ts. N.; Petkov, B. H.; Krastev, D. G.

    The results from direct ground-based solar UV irradiance measurements and the total ozone content (TOC) over Stara Zagora (42° 25'N, 25° 37'E), Bulgaria are presented. During the period 1999-2003 the TOC data show seasonal variations, typical for the middle latitudes - maximum in the spring and minimum in the autumn. The comparison between TOC ground-based data and Global Ozone Monitoring Experiment (GOME) satellite-borne ones shows a seasonal dependence of the differences between them. A strong negative relationship between the total ozone and the 305 nm wavelength irradiance was found. The dependence between the two variables is significant ( r = -0.62 ± 0.18) at 98% confidence level. The direct sun UV doses for some specific biological effects (erythema and eyes) are obtained. The estimation of the radiation amplification factor RAF shows that the ozone reduction by 1% increases the erythemal dose by 2.3%. The eye-damaging doses are more influenced by the TOC changes and in this case RAF = -2.7%. The amount of these biological doses depended on the solar altitude over the horizon. This dependence was not so strong when the total ozone content in the atmosphere was lower.

  16. Clinical Usefulness of serum total cholesterol as an index of hypothyroidism in patients after cervical radiation

    International Nuclear Information System (INIS)

    Iguma, Yoko; Iwai, Chikako; Okuyama, Masako; Futami, Takahiro; Inui, Ken-ichi; Asato, Ryo

    2003-01-01

    Cervical radiation therapy is often applied to patients with head and neck cancers because radiation has a high sensitivity to these cancers and permits the preservation of functions and physical form. However, it has been shown that various complications can result from radiation therapy. We have encountered some patients who showed hypercholesterolemia resulting from cervical radiation. Therefore, we have paid close attention to the relationship between hypercholesterolemia after cervical radiation and hypothyroidism. Thyroid hormone tests in these patients with hypercholesterolemia after cervical radiation showed high thyroid stimulating hormone (TSH) and low free thyroxine (fT 4 ), indicating the presence of hypothyroidism. After administration of levothyroxine Na, their fT 4 levels increased and both TSH levels and serum total cholesterol levels decreased. In conclusion, in patients who have received cervical radiation, we recommend monitoring serum total cholesterol periodically to detect hypothyroidism easily before the appearance of its symptoms. (author)

  17. Clinical Usefulness of serum total cholesterol as an index of hypothyroidism in patients after cervical radiation

    Energy Technology Data Exchange (ETDEWEB)

    Iguma, Yoko; Iwai, Chikako; Okuyama, Masako; Futami, Takahiro; Inui, Ken-ichi [Kyoto Univ. (Japan). Hospital; Asato, Ryo [Kyoto Univ. (Japan). Graduate School of Medicine

    2003-02-01

    Cervical radiation therapy is often applied to patients with head and neck cancers because radiation has a high sensitivity to these cancers and permits the preservation of functions and physical form. However, it has been shown that various complications can result from radiation therapy. We have encountered some patients who showed hypercholesterolemia resulting from cervical radiation. Therefore, we have paid close attention to the relationship between hypercholesterolemia after cervical radiation and hypothyroidism. Thyroid hormone tests in these patients with hypercholesterolemia after cervical radiation showed high thyroid stimulating hormone (TSH) and low free thyroxine (fT{sub 4}), indicating the presence of hypothyroidism. After administration of levothyroxine Na, their fT{sub 4} levels increased and both TSH levels and serum total cholesterol levels decreased. In conclusion, in patients who have received cervical radiation, we recommend monitoring serum total cholesterol periodically to detect hypothyroidism easily before the appearance of its symptoms. (author)

  18. Directional radiative cooling thermal compensation for gravitational wave interferometer mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Justin Kamp, Carl [Department of Chemical Reaction Engineering, Chalmers University of Technology, SE-412 96 Goteborg (Sweden)], E-mail: carl.kamp@chalmers.se; Kawamura, Hinata [Yokoyama Junior High School, Sanda, Hachioji, Tokyo 193-0832 (Japan); Passaquieti, Roberto [Dipartimento di Fisica ' Enrico Fermi' and INFN Sezione di Pisa, Universita' di Pisa, Largo Bruno Pontecorvo, I-56127 Pisa (Italy); DeSalvo, Riccardo [LIGO Observatories, California Institute of Technology, Pasadena, CA 91125 (United States)

    2009-08-21

    The concept of utilizing directional radiative cooling to correct the problem of thermal lensing in the mirrors of the LIGO/VIRGO gravitational wave detectors has been shown and has prospects for future use. Two different designs utilizing this concept, referred to as the baffled and parabolic mirror solutions, have been proposed with different means of controlling the cooling power. The technique takes advantage of the power naturally radiated by the mirror surfaces at room temperature to prevent their heating by the powerful stored laser beams. The baffled solution has been simulated via COMSOL Multiphysics as a design tool. Finally, the parabolic mirror concept was experimentally validated with the results falling in close agreement with theoretical cooling calculations. The technique of directional radiative thermal correction can be reversed to image heat rings on the mirrors periphery to remotely and dynamically correct their radius of curvature without subjecting the mirror to relevant perturbations.

  19. Monsoon sensitivity to aerosol direct radiative forcing in the ...

    Indian Academy of Sciences (India)

    to the total, scattering aerosols and black carbon aerosols. ... acts as an internal damping mechanism spinning down the regional hydrological cycle and leading to sig- ... tion and emission of longwave radiation. ... effect of aerosols over India, where the emission of .... that aerosol effects on monsoon water cycle dynam-.

  20. Direct Computation of Sound Radiation by Jet Flow Using Large-scale Equations

    Science.gov (United States)

    Mankbadi, R. R.; Shih, S. H.; Hixon, D. R.; Povinelli, L. A.

    1995-01-01

    Jet noise is directly predicted using large-scale equations. The computational domain is extended in order to directly capture the radiated field. As in conventional large-eddy-simulations, the effect of the unresolved scales on the resolved ones is accounted for. Special attention is given to boundary treatment to avoid spurious modes that can render the computed fluctuations totally unacceptable. Results are presented for a supersonic jet at Mach number 2.1.

  1. Total dose and dose rate radiation characterization of EPI-CMOS radiation hardened memory and microprocessor devices

    International Nuclear Information System (INIS)

    Gingerich, B.L.; Hermsen, J.M.; Lee, J.C.; Schroeder, J.E.

    1984-01-01

    The process, circuit discription, and total dose radiation characteristics are presented for two second generation hardened 4K EPI-CMOS RAMs and a first generation 80C85 microprocessor. Total dose radiation performance is presented to 10M rad-Si and effects of biasing and operating conditions are discussed. The dose rate sensitivity of the 4K RAMs is also presented along with single event upset (SEU) test data

  2. Direct coronary stenting in reducing radiation and radiocontrast consumption

    International Nuclear Information System (INIS)

    Caluk, Jasmin; Osmanovic, Enes; Barakovic, Fahir; Kusljugic, Zumreta; Terzic, Ibrahim; Caluk, Selma; Sofic, Amela

    2010-01-01

    Coronary stenting is the primary means of coronary revascularization. There are two basic techniques of stent implantation: stenting with balloon predilatation of stenosis and stenting without predilatation (direct stenting). Limiting the time that a fluoroscope is activated and by appropriately managing the intensity of the applied radiation, the operator limits radiation in the environment, and this saves the exposure to the patient and all personnel in the room. Nephrotoxicity is one of the most important properties of radiocontrast. The smaller amount of radiocontrast used also provides multiple positive effects, primarily regarding the periprocedural risk for the patients with the reduced renal function. The goal of the study was to compare fluoroscopy time, the amount of radiocontrast, and expenses of material used in direct stenting and in stenting with predilatation. In a prospective study, 70 patients with coronary disease were randomized to direct stenting, or stenting with predilatation. Fluoroscopy time and radiocontrast use were significantly reduced in the directly stented patients in comparison to the patients stented with balloon-predilatation. The study showed a significant reduction of expenses when using a direct stenting method in comparison to stenting with predilatation. If the operator predicts that the procedure can be performed using direct stenting, he is encouraged to do so. Direct stenting is recommended for all percutaneous coronary interventions when appropriate conditions have been met. If direct stenting has been unsuccessful, the procedure can be converted to predilatation

  3. Estimating hourly direct and diffuse solar radiation for the compilation of solar radiation distribution maps

    International Nuclear Information System (INIS)

    Ueyama, H.

    2005-01-01

    This paper presents a new method for estimating hourly direct and diffuse solar radiation. The essence of the method is the estimation of two important factors related to solar radiation, atmospheric transmittance and a dimensionless parameter, using empirical and physical equations and data from general meteorological observation stations. An equation for atmospheric transmittance of direct solar radiation and a dimensionless parameter representing diffuse solar radiation are developed. The equation is based on multiple regression analysis and uses three parameters as explanatory variates: calculated hourly extraterrestrial solar radiation on a horizontal plane, observed hourly sunshine duration and hourly precipitation as observed at a local meteorological observatory. The dimensionless parameter for estimating a diffuse solar radiation is then determined by linear least squares using observed hourly solar radiation at a local meteorological observatory. The estimated root mean square error (RMSE) of hourly direct and diffuse solar radiation is about 0.0-0.2 MJ¥m(-2)¥h(-1) in each mean period. The RMSE of the ten-day and monthly means of these quantities is about 0.0-0.2 MJ¥m(-2)¥h(-1), based on comparisons with AMeDAS station data, located at a distance of 6 km

  4. Passive radiative cooling below ambient air temperature under direct sunlight.

    Science.gov (United States)

    Raman, Aaswath P; Anoma, Marc Abou; Zhu, Linxiao; Rephaeli, Eden; Fan, Shanhui

    2014-11-27

    Cooling is a significant end-use of energy globally and a major driver of peak electricity demand. Air conditioning, for example, accounts for nearly fifteen per cent of the primary energy used by buildings in the United States. A passive cooling strategy that cools without any electricity input could therefore have a significant impact on global energy consumption. To achieve cooling one needs to be able to reach and maintain a temperature below that of the ambient air. At night, passive cooling below ambient air temperature has been demonstrated using a technique known as radiative cooling, in which a device exposed to the sky is used to radiate heat to outer space through a transparency window in the atmosphere between 8 and 13 micrometres. Peak cooling demand, however, occurs during the daytime. Daytime radiative cooling to a temperature below ambient of a surface under direct sunlight has not been achieved because sky access during the day results in heating of the radiative cooler by the Sun. Here, we experimentally demonstrate radiative cooling to nearly 5 degrees Celsius below the ambient air temperature under direct sunlight. Using a thermal photonic approach, we introduce an integrated photonic solar reflector and thermal emitter consisting of seven layers of HfO2 and SiO2 that reflects 97 per cent of incident sunlight while emitting strongly and selectively in the atmospheric transparency window. When exposed to direct sunlight exceeding 850 watts per square metre on a rooftop, the photonic radiative cooler cools to 4.9 degrees Celsius below ambient air temperature, and has a cooling power of 40.1 watts per square metre at ambient air temperature. These results demonstrate that a tailored, photonic approach can fundamentally enable new technological possibilities for energy efficiency. Further, the cold darkness of the Universe can be used as a renewable thermodynamic resource, even during the hottest hours of the day.

  5. Radiation damage of DNA. Model for direct ionization of DNA

    International Nuclear Information System (INIS)

    Kobayashi, Kazuo; Tagawa, Seiichi

    2004-01-01

    Current aspects of radiation damage of DNA, particularly induced by the direct effect of radiation, and author's method of pulse radiolysis are described in relation to behavior of ions formed by radiation and active principles to induce the strand break. In irradiation of DNA solution in water, the direct effect of radiation is derived from ionization of DNA itself and indirect one, from the reaction between DNA and radicals generated from water molecules and the former direct one has been scarcely investigated due to difficulty of experimental approach. Radicals generated in sugar moiety of DNA are shown important in the strand break by recent studies on crystalline DNA irradiated by X-ray, DNA solution by electron and photon beams, hydrated DNA by γ-ray and by high linear energy transfer (LET) ion. Author's pulse radiolysis studies have revealed behaviors of guanine and adenine radical cations in dynamics of DNA oxidation. Since reactions described are the model, the experimental approach is thought necessary for elucidation of the actually occurring DNA damage in living cells. (N.I.)

  6. Neuropsychological effects of cranial radiation: current knowledge and future directions

    International Nuclear Information System (INIS)

    Roman, Deborah D.; Sperduto, Paul W.

    1995-01-01

    Radiation is an invaluable therapeutic tool in the treatment of cancer, with well-established palliative and curative efficacy. As patient survival has improved, attention has focused on long-range treatment side effects. One such adverse effect, neuropsychological impairment, is incompletely understood. Much of the extant research has been directed at childhood leukemia survivors treated with low-dose whole-brain radiation. Less is known about the effects of high-dose focal or whole-brain radiation used in the treatment of brain lesions. This article reviews the scientific literature in this area, with greatest emphasis on methodologically rigorous studies. Research design considerations are discussed. Review findings suggest that low-dose whole-brain radiation (18 to 24 Gy) in children is associated with mild delayed IQ decline, with more substantial deficits occurring in children treated at a young age. A high incidence of learning disabilities and academic failure is observed in this population and may be caused by poor attention and memory rather than low intellectual level. Children who receive higher dose radiation for treatment of brain tumors experience more pronounced cognitive decline. At higher doses, whole-brain radiation, in particular, is linked to deleterious cognitive outcomes. Remarkably little is known about cognitive outcomes in irradiated adults. Preliminary findings indicate that certain cognitive functions, including memory, may be more vulnerable to decline than others. Suggestions for future research are proposed

  7. Using a simple apparatus to measure direct and diffuse photosynthetically active radiation at remote locations.

    Directory of Open Access Journals (Sweden)

    Michael J Cruse

    Full Text Available Plant canopy interception of photosynthetically active radiation (PAR drives carbon dioxide (CO2, water and energy cycling in the soil-plant-atmosphere system. Quantifying intercepted PAR requires accurate measurements of total incident PAR above canopies and direct beam and diffuse PAR components. While some regional data sets include these data, e.g. from Atmospheric Radiation Measurement (ARM Program sites, they are not often applicable to local research sites because of the variable nature (spatial and temporal of environmental variables that influence incoming PAR. Currently available instrumentation that measures diffuse and direct beam radiation separately can be cost prohibitive and require frequent adjustments. Alternatively, generalized empirical relationships that relate atmospheric variables and radiation components can be used but require assumptions that increase the potential for error. Our goal here was to construct and test a cheaper, highly portable instrument alternative that could be used at remote field sites to measure total, diffuse and direct beam PAR for extended time periods without supervision. The apparatus tested here uses a fabricated, solar powered rotating shadowband and other commercially available parts to collect continuous hourly PAR data. Measurements of total incident PAR had nearly a one-to-one relationship with total incident radiation measurements taken at the same research site by an unobstructed point quantum sensor. Additionally, measurements of diffuse PAR compared favorably with modeled estimates from previously published data, but displayed significant differences that were attributed to the important influence of rapidly changing local environmental conditions. The cost of the system is about 50% less than comparable commercially available systems that require periodic, but not continual adjustments. Overall, the data produced using this apparatus indicates that this instrumentation has the

  8. Development and deployment of the Collimated Directional Radiation Detection System

    Science.gov (United States)

    Guckes, Amber L.; Barzilov, Alexander

    2017-09-01

    The Collimated Directional Radiation Detection System (CDRDS) is capable of imaging radioactive sources in two dimensions (as a directional detector). The detection medium of the CDRDS is a single Cs2LiYCl6:Ce3+ scintillator cell enriched in 7Li (CLYC-7). The CLYC-7 is surrounded by a heterogeneous high-density polyethylene (HDPE) and lead (Pb) collimator. These materials make-up a coded aperture inlaid in the collimator. The collimator is rotated 360° by a stepper motor which enables time-encoded imaging of a radioactive source. The CDRDS is capable of spectroscopy and pulse shape discrimination (PSD) of photons and fast neutrons. The measurements of a radioactive source are carried out in discrete time steps that correlate to the angular rotation of the collimator. The measurement results are processed using a maximum likelihood expectation (MLEM) algorithm to create an image of the measured radiation. This collimator design allows for the directional detection of photons and fast neutrons simultaneously by utilizing only one CLYC-7 scintillator. Directional detection of thermal neutrons can also be performed by utilizing another suitable scintillator. Moreover, the CDRDS is portable, robust, and user friendly. This unit is capable of utilizing wireless data transfer for possible radiation mapping and network-centric applications. The CDRDS was tested by performing laboratory measurements with various gamma-ray and neutron sources.

  9. Radiation-induced alternative transcripts as detected in total and polysome-bound mRNA.

    Science.gov (United States)

    Wahba, Amy; Ryan, Michael C; Shankavaram, Uma T; Camphausen, Kevin; Tofilon, Philip J

    2018-01-02

    Alternative splicing is a critical event in the posttranscriptional regulation of gene expression. To investigate whether this process influences radiation-induced gene expression we defined the effects of ionizing radiation on the generation of alternative transcripts in total cellular mRNA (the transcriptome) and polysome-bound mRNA (the translatome) of the human glioblastoma stem-like cell line NSC11. For these studies, RNA-Seq profiles from control and irradiated cells were compared using the program SpliceSeq to identify transcripts and splice variations induced by radiation. As compared to the transcriptome (total RNA) of untreated cells, the radiation-induced transcriptome contained 92 splice events suggesting that radiation induced alternative splicing. As compared to the translatome (polysome-bound RNA) of untreated cells, the radiation-induced translatome contained 280 splice events of which only 24 were overlapping with the radiation-induced transcriptome. These results suggest that radiation not only modifies alternative splicing of precursor mRNA, but also results in the selective association of existing mRNA isoforms with polysomes. Comparison of radiation-induced alternative transcripts to radiation-induced gene expression in total RNA revealed little overlap (about 3%). In contrast, in the radiation-induced translatome, about 38% of the induced alternative transcripts corresponded to genes whose expression level was affected in the translatome. This study suggests that whereas radiation induces alternate splicing, the alternative transcripts present at the time of irradiation may play a role in the radiation-induced translational control of gene expression and thus cellular radioresponse.

  10. Inclusion of Radiation Environment Variability in Total Dose Hardness Assurance Methodology

    Science.gov (United States)

    Xapsos, M. A.; Stauffer, C.; Phan, A.; McClure, S. S.; Ladbury, R. L.; Pellish, J. A.; Campola, M. J.; LaBel, K. A.

    2016-01-01

    Variability of the space radiation environment is investigated with regard to parts categorization for total dose hardness assurance methods. It is shown that it can have a significant impact. A modified approach is developed that uses current environment models more consistently and replaces the radiation design margin concept with one of failure probability during a mission.

  11. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  12. Malfunction of cardiac devices after radiotherapy without direct exposure to ionizing radiation: mechanisms and experimental data.

    Science.gov (United States)

    Zecchin, Massimo; Morea, Gaetano; Severgnini, Mara; Sergi, Elisabetta; Baratto Roldan, Anna; Bianco, Elisabetta; Magnani, Silvia; De Luca, Antonio; Zorzin Fantasia, Anna; Salvatore, Luca; Milan, Vittorino; Giannini, Gianrossano; Sinagra, Gianfranco

    2016-02-01

    Malfunctions of cardiac implantable electronical devices (CIED) have been described after high-energy radiation therapy even in the absence of direct exposure to ionizing radiation, due to diffusion of neutrons (n) causing soft errors in inner circuits. The purpose of the study was to analyse the effect of scattered radiation on different types and models of CIED and the possible sources of malfunctions. Fifty-nine explanted CIED were placed on an anthropomorphous phantom of tissue-equivalent material, and a high-energy photon (15 MV) radiotherapy course (total dose = 70 Gy) for prostate treatment was performed. All devices were interrogated before and after radiation. Radiation dose, the electromagnetic field, and neutron fluence at the CIED site were measured. Thirty-four pacemakers (PM) and 25 implantable cardioverter-defibrillators (ICD) were analysed. No malfunctions were detected before radiation. After radiation a software malfunction was evident in 13 (52%) ICD and 6 (18%) PM; no significant electromagnetic field or photon radiations were detected in the thoracic region. Neutron capture was demonstrated by the presence of the (198)Au((197)Au + n) or (192)Ir((191)Ir + n) isotope activation; it was significantly greater in ICD than in PM and non-significantly greater in damaged devices. A greater effect in St Jude PM (2/2 damaged), Boston (9/11), and St Jude ICD (3/6) and in older ICD models was observed; the year of production was not relevant in PM. High-energy radiation can cause different malfunctions on CIED, particularly ICD, even without direct exposure to ionizing radiation due to scattered radiation of neutrons produced by the linear accelerator. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  13. Effect of gamma radiation on total antioxidant capacity, total lipid concentration and shelf life of finger millet flour

    International Nuclear Information System (INIS)

    Lathika; Manupriya, B.R.; Shenoy, K.B.; Patil, S.L.; Somashekarappa, H.M.

    2016-01-01

    The present study is an attempt to study the impact of gamma radiation on the shelf life, total antioxidant capacity and total lipid concentration of finger millet (Eleusine coracana L.) flour. Finger millet flour was procured from market. Flour samples of 50 g were taken in triplicates in a polyethylene pouch, air sealed and subjected to gamma irradiation doses ranging from 0.25 to 10 kGy and stored in polyethylene bags and plastic containers for a period of 1 year. Within 24 hours of irradiation, the samples were tested for moisture (2 ± 0.2%), total antioxidant capacity (0.12 ± 0.010 mg) and lipid concentration (15 ± 0.4 mg)

  14. Direct radiative effects during intense Mediterranean desert dust outbreaks

    Directory of Open Access Journals (Sweden)

    A. Gkikas

    2018-06-01

    Full Text Available The direct radiative effect (DRE during 20 intense and widespread dust outbreaks, which affected the broader Mediterranean basin over the period March 2000–February 2013, has been calculated with the NMMB-MONARCH model at regional (Sahara and European continent and short-term temporal (84 h scales. According to model simulations, the maximum dust aerosol optical depths (AODs range from  ∼  2.5 to  ∼  5.5 among the identified cases. At midday, dust outbreaks locally induce a NET (shortwave plus longwave strong atmospheric warming (DREATM values up to 285 W m−2; Niger–Chad; dust AODs up to  ∼  5.5 and a strong surface cooling (DRENETSURF values down to −337 W m−2, whereas they strongly reduce the downward radiation at the ground level (DRESURF values down to −589 W m−2 over the Eastern Mediterranean, for extremely high dust AODs, 4.5–5. During night-time, reverse effects of smaller magnitude are found. At the top of the atmosphere (TOA, positive (planetary warming DREs up to 85 W m−2 are found over highly reflective surfaces (Niger–Chad; dust AODs up to  ∼  5.5 while negative (planetary cooling DREs down to −184 W m−2 (Eastern Mediterranean; dust AODs 4.5–5 are computed over dark surfaces at noon. Dust outbreaks significantly affect the mean regional radiation budget, with NET DREs ranging from −8.5 to 0.5 W m−2, from −31.6 to 2.1 W m−2, from −22.2 to 2.2 W m−2 and from −1.7 to 20.4 W m−2 for TOA, SURF, NETSURF and ATM, respectively. Although the shortwave DREs are larger than the longwave ones, the latter are comparable or even larger at TOA, particularly over the Sahara at midday. As a response to the strong surface day-time cooling, dust outbreaks cause a reduction in the regional sensible and latent heat fluxes by up to 45 and 4 W m−2, respectively, averaged over land areas of the simulation domain. Dust outbreaks reduce the

  15. Direct and semi-direct radiative forcing of smoke aerosols over clouds

    Directory of Open Access Journals (Sweden)

    E. M. Wilcox

    2012-01-01

    Full Text Available Observations from Earth observing satellites indicate that dark carbonaceous aerosols that absorb solar radiation are widespread in the tropics and subtropics. When these aerosols mix with clouds, there is generally a reduction of cloudiness owing to absorption of solar energy in the aerosol layer. Over the subtropical South Atlantic Ocean, where smoke from savannah burning in southern Africa resides above a persistent deck of marine stratocumulus clouds, radiative heating of the smoke layer leads to a thickening of the cloud layer. Here, satellite observations of the albedo of overcast scenes of 25 km2 size or larger are combined with additional satellite observations of clouds and aerosols to estimate the top-of-atmosphere direct radiative forcing attributable to presence of dark aerosol above bright cloud, and the negative semi-direct forcing attributable to the thickening of the cloud layer. The average positive direct radiative forcing by smoke over an overcast scene is 9.2±6.6 W m−2 for cases with an unambiguous signal of absorbing aerosol over cloud in passive ultraviolet remote sensing observations. However, cloud liquid water path is enhanced by 16.3±7.7 g m−2 across the range of values for sea surface temperature for cases of smoke over cloud. The negative radiative forcing associated with this semi-direct effect of smoke over clouds is estimated to be −5.9±3.5 W m−2. Therefore, the cooling associated with the semi-direct cloud thickening effect compensates for greater than 60 % of the direct radiative effect. Accounting for the frequency of occurrence of significant absorbing aerosol above overcast scenes leads to an estimate of the average direct forcing of 1.0±0.7 W m−2 contributed by these scenes averaged over the subtropical southeast Atlantic Ocean during austral winter. The regional average of the negative semi-direct forcing is −0.7±0.4 W m−2

  16. Development of a novel gamma probe for detecting radiation direction

    Science.gov (United States)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Longo, M.; Donnarumma, R.; D'Alessio, A.; Borrazzo, C.; Pergola, A.; Ridolfi, S.; De Vincentis, G.

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security.

  17. Development of a novel gamma probe for detecting radiation direction

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M.N.; Longo, M.; Donnarumma, R.; Borrazzo, C.; D'Alessio, A.; Pergola, A.; Ridolfi, S.; Vincentis, G. De

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security

  18. Ultra-Low Power Consuming Direct Radiation Sensors Based on Floating Gate Structures

    Directory of Open Access Journals (Sweden)

    Evgeny Pikhay

    2017-07-01

    Full Text Available In this paper, we report on ultra-low power consuming single poly floating gate direct radiation sensors. The developed devices are intended for total ionizing dose (TID measurements and fabricated in a standard CMOS process flow. Sensor design and operation is discussed in detail. Original array sensors were suggested and fabricated that allowed high statistical significance of the radiation measurements and radiation imaging functions. Single sensors and array sensors were analyzed in combination with the specially developed test structures. This allowed insight into the physics of sensor operations and exclusion of the phenomena related to material degradation under irradiation in the interpretation of the measurement results. Response of the developed sensors to various sources of ionizing radiation (Gamma, X-ray, UV, energetic ions was investigated. The optimal design of sensor for implementation in dosimetry systems was suggested. The roadmap for future improvement of sensor performance is suggested.

  19. Design and radiation tests on a LED based emergency evacuation directional lighting

    CERN Document Server

    Trikoupis, Nikolaos

    2017-01-01

    A LED (Light Emitting Diode) based directional lighting system has been designed to indicate the best evacuation direction for applications like the Large Hadron Collider (LHC) tunnel. The design includes constraints for redundancy required by safety systems and for components selection by radiation effects. Most of the literature for radiation effects on LEDs concern digital communications systems, although some recent reports do exist for visible spectrum power LEDs and the reduction in light output versus dose is coherent with the results presented in this paper. Prototype lighting units were irradiated in CERN’s CHARM facility up to a Total Integrated Dose (TID) of 870 Gy and no failures were observed. This paper describes the basic design, presents field tests and the effects of radiation on the LEDs luminance.

  20. Think the way to measure the Earth Radiation Budget and the Total Solar Irradiance with a small satellites constellation

    Science.gov (United States)

    Meftah, M.; Keckhut, P.; Damé, L.; Bekki, S.; Sarkissian, A.; Hauchecorne, A.

    2018-05-01

    Within the past decade, satellites constellations have become possible and practical. One of the interest to use a satellites constellation is to measure the true Earth Radiation Imbalance, which is a crucial quantity for testing climate models and for predicting the future course of global warming. This measurement presents a high interest because the 2001-2010 decade has not shown the accelerating pace of global warming that most models predict, despite the fact that the greenhouse-gas radiative forcing continues to rise. All estimates (ocean heat content and top of atmosphere) show that over the past decade the Earth radiation imbalance ranges between 0.5 to 1W-2. Up to now, the Earth radiation imbalance has not been measured directly. The only way to measure the imbalance with sufficient accuracy is to measure both the incoming solar radiations (total solar irradiance) and the outgoing terrestrial radiations (top of atmosphere outgoing longwave radiations and shortwave radiations) onboard the same satellite, and ideally, with the same instrument. The incoming solar radiations and the outgoing terrestrial radiations are of nearly equal magnitude of the order of 340.5W-2. The objective is to measure these quantities over time by using differential Sun-Earth measurements (to counter calibration errors) with an accuracy better than 0.05Wm-2 at 1σ. It is also necessary to have redundant instruments to track aging in space in order to measure during a decade and to measure the global diurnal cycle with a dozen satellites. Solar irradiance and Earth Radiation Budget (SERB) is a potential first in orbit demonstration satellite. The SERB nano-satellite aims to measure on the same platform the different components of the Earth radiation budget and the total solar irradiance. Instrumental payloads (solar radiometer and Earth radiometers) can acquire the technical maturity for the future large missions (constellation that insure global measurement cover) by flying in a

  1. Direct energy conversion of radiation energy in fusion reactor

    International Nuclear Information System (INIS)

    Yamaguchi, S.; Iiyoshi, A.; Motojima, O.; Okamoto, M.; Sudo, S.; Ohnishi, M.; Onozuka, M.; Uenosono, C.

    1993-11-01

    Direct energy conversion from plasma heat flux has been studied. Since major parts of fusion energy in the advanced fusion reactor are radiation and charged particle energies, the flexible design of the blanket is possible. We discuss the potentiality of the thermoelectric element that generates electricity by temperature gradient in conductors. A strong magnetic field is used to confine the fusion plasma, therefore, it is appropriate to consider the effect of the magnetic field. We propose a new element which is called Nernst element. The new element needs the magnetic field and the temperature gradient. We compare the efficiency of these two elements in a semiconductor model. Finally, a direct energy conversion are mentioned. (author)

  2. Direct energy conversion of radiation energy in fusion reactor

    Science.gov (United States)

    Yamaguchi, S.; Iiyoshi, A.; Motojima, O.; Okamoto, M.; Sudo, S.; Ohnishi, M.; Onozuka, M.; Uenosono, C.

    1993-11-01

    Direct energy conversion from plasma heat flux has been studied. Since major parts of fusion energy in the advanced fusion reactor are radiation and charged particle energies, the flexible design of the blanket is possible. We discuss the potentiality of the thermoelectric element that generates electricity by temperature gradient in conductors. A strong magnetic field is used to confine the fusion plasma, therefore, it is appropriate to consider the effect of the magnetic field. We propose a new element which is called Nernst element. The new element needs the magnetic field and the temperature gradient. We compare the efficiency of these two elements in a semiconductor model. Finally, a direct energy conversion are mentioned.

  3. Direct energy conversion of radiation energy in fusion reactor

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, S.; Iiyoshi, A.; Motojima, O.; Okamoto, M.; Sudo, S.; Ohnishi, M.; Onozuka, M.; Uenosono, C.

    1993-11-01

    Direct energy conversion from plasma heat flux has been studied. Since major parts of fusion energy in the advanced fusion reactor are radiation and charged particle energies, the flexible design of the blanket is possible. We discuss the potentiality of the thermoelectric element that generates electricity by temperature gradient in conductors. A strong magnetic field is used to confine the fusion plasma, therefore, it is appropriate to consider the effect of the magnetic field. We propose a new element which is called Nernst element. The new element needs the magnetic field and the temperature gradient. We compare the efficiency of these two elements in a semiconductor model. Finally, a direct energy conversion are mentioned. (author).

  4. Direct energy conversion of radiation energy in fusion reactor

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, S.; Iiyoshi, A.; Motojima, O.; Okamoto, M.; Sudo, S. [National Inst. for Fusion Science, Nagoya (Japan); Ohnishi, M.; Onozuka, M.; Uenosono, C.

    1994-12-31

    Direct energy conversion from plasma heat flux has been studied. Since major parts of fusion energy in the advanced fusion reactor are radiation and charged particle energies, the flexible design of the blanket is possible. We discuss the potentiality of the thermoelectric element that generate electricity by temperature gradient in conductors. A Strong magnetic field is used to confine the fusion plasma, therefore, it is appropriate to consider the effect of the magnetic field. We propose a new element which is called Nernst element. The new element needs the magnetic field and the temperature gradient. We compare the efficiency of these two elements in a semiconductor model. Finally, a direct energy converter are mentioned. (author).

  5. Direct energy conversion of radiation energy in fusion reactor

    International Nuclear Information System (INIS)

    Yamaguchi, S.; Iiyoshi, A.; Motojima, O.; Okamoto, M.; Sudo, S.; Ohnishi, M.; Onozuka, M.; Uenosono, C.

    1994-01-01

    Direct energy conversion from plasma heat flux has been studied. Since major parts of fusion energy in the advanced fusion reactor are radiation and charged particle energies, the flexible design of the blanket is possible. We discuss the potentiality of the thermoelectric element that generate electricity by temperature gradient in conductors. A Strong magnetic field is used to confine the fusion plasma, therefore, it is appropriate to consider the effect of the magnetic field. We propose a new element which is called Nernst element. The new element needs the magnetic field and the temperature gradient. We compare the efficiency of these two elements in a semiconductor model. Finally, a direct energy converter are mentioned. (author)

  6. Direct action of low doses of radiation of neurons

    International Nuclear Information System (INIS)

    Peimer, S.I.; Dudkin, A.O.; Sverdlov, A.G.

    1986-01-01

    The authors experiment with new technology of surviving mammalian brain sections for the detection of the direct action of ionizing radiation on the functioning neurons of mammals. The authors selected the rat hippocampus as the object of investigation. Sections of the hippocampus were prepared according to standard procedure, 0.3 mm thick, and incubated for several hours under the following conditions: temperature 35.5 0 C, rate of perfusion 2-3 ml/min, rate of delivery of a mixture of oxygen (95%), and carbon monoxide (5%), in the perfusion solution 35 ml/min. Composition of solution (mM): NaCl 124, KCl 5, CACl 2 2.4, MgSO 4 1.3, NaHCO 3 26, glucose 10; pH 7.4. In an individual series of experiments, calcium was not added to the solution, but an excess of magnesium ions was introduced up to 2.6 mM. Extracellular takeoffs were performed with glass microelectrodes. For irradiation, the authors used sources of x-rays and gamma radiation. In the 5-DI x-ray apparatus, the working voltage and current on the tube were 50 quanta and 8 mA, respectively; there were no filters. Gamma irradiation was performed using ampuls with the radionuclide cesium-137 (IGI-C-3 type), which can be delivered on a holder directly to the section for 1 min

  7. Radiation protection in dental radiology - Recent advances and future directions.

    Science.gov (United States)

    Tsapaki, V

    2017-12-01

    Dental radiology uses X-ray technology to diagnose and design treatment of various clinical problems related to the oral cavity and surrounding tissues. As technology quickly evolves, there are numerous X-ray modalities using different tools in the attempt to best image and treat efficiently these diseases, disorders or other related clinical conditions. The reported numbers of dental X-rays, the fact that these may be under-reported in many countries and because dental X-rays are performed more on younger individuals, whose teeth and dentition are still developing, calls for increased need on radiation protection. The objectives of this paper are to report on the latest technology updates and related radiation protection issues, to present future directions and define gaps. Most of existing radiation protection national and international guidelines are more than a decade old. Update is needed to account for newer technologies such as cone beam computed tomography (CBCT) and digital imaging. Diagnostic Reference Levels (DRLs), a well established method for dose optimization, are not yet defined for CBCT and have to be set for various clinical indications. As far as shielding is concerned, recent data confirm that use of lead apron, even in pregnant patients, or gonadal shielding are not recommended, due to negligible radiation dose reduction. Thyroid lead shielding should be used in case the organ is in or close to the primary beam. Specifically for CBCT, leaded glasses, thyroid collars and collimation (smaller field of view (FOV) especially for paediatric patients) minimize the dose to organs outside the FOV. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Reduction of radiation exposure for the examiner in angiography using a direct dosimeter

    International Nuclear Information System (INIS)

    Kamusella, Peter; Wissgott, C.; Scheer, F.; Andresen, R.; Wiggermann, P.

    2013-01-01

    Purpose: To evaluate whether a reduction in radiation exposure can be achieved using a direct dosimeter with an acoustic warning signal (model EDD-30, Unfors Instruments, Billdal, Sweden). Materials and Methods: A total of 183 diagnostic and interventional angiographies of the pelvis and lower limbs using a direct dosimeter were analyzed. The vascular interventions were performed either by an experienced examiner (> 5000 interventions), an intermediate examiner (> 1000 interventions) or by a beginner (< 200 interventions). The measuring sensor of the direct dosimeter was attached to the back of the left hand, below the sterile glove, and was worn throughout the examination. If the limit values set on the dosimeter were exceeded, an acoustic signal sounded. At the end of the examination, the mean dose and the mean dose rate could be read off directly. Results: Exposure is clearly dependent on the experience of the examiner. The highest mean dose rate was found for the beginner, followed by the intermediate examiner. The lowest dose rate was shown by the experienced examiner, even though he mostly performed complex interventions. Over the course of 3 months, an improvement in the average dose rate can be shown in the third month for the intermediate examiner. Conclusion: The use of a direct dosimeter with an acoustic warning signal is a practicable tool for sensitizing interventional radiologists to unavoidable radiation exposure, with the aim of reducing the dose. 'Real-time' dosimetry represents a sensible extension of indirect protection of the radiation-exposed examiner in angiography. (orig.)

  9. Directional radiometry and radiative transfer: A new paradigm

    International Nuclear Information System (INIS)

    Mishchenko, Michael I.

    2011-01-01

    Measurements with directional radiometers and calculations based on the radiative transfer equation (RTE) have been at the very heart of weather and climate modeling and terrestrial remote sensing. The quantification of the energy budget of the Earth's climate system requires exquisite measurements and computations of the incoming and outgoing electromagnetic energy, while global characterization of climate system's components relies heavily on theoretical inversions of observational data obtained with various passive and active instruments. The same basic problems involving electromagnetic energy transport and its use for diagnostic and characterization purposes are encountered in numerous other areas of science, biomedicine, and engineering. Yet both the discipline of directional radiometry and the radiative transfer theory (RTT) have traditionally been based on phenomenological concepts many of which turn out to be profound misconceptions. Contrary to the widespread belief, a collimated radiometer does not, in general, measure the flow of electromagnetic energy along its optical axis, while the specific intensity does not quantify the amount of electromagnetic energy transported in a given direction. The recently developed microphysical approach to radiative transfer and directional radiometry is explicitly based on the Maxwell equations and clarifies the physical nature of measurements with collimated radiometers and the actual content of the RTE. It reveals that the specific intensity has no fundamental physical meaning besides being a mathematical solution of the RTE, while the RTE itself is nothing more than an intermediate auxiliary equation. Only under special circumstances detailed in this review can the solution of the RTE be used to compute the time-averaged local Poynting vector as well as be measured by a collimated radiometer. These firmly established facts make the combination of the RTE and a collimated radiometer useful in a well-defined range of

  10. Acute Radiation Syndrome Severity Score System in Mouse Total-Body Irradiation Model.

    Science.gov (United States)

    Ossetrova, Natalia I; Ney, Patrick H; Condliffe, Donald P; Krasnopolsky, Katya; Hieber, Kevin P

    2016-08-01

    Radiation accidents or terrorist attacks can result in serious consequences for the civilian population and for military personnel responding to such emergencies. The early medical management situation requires quantitative indications for early initiation of cytokine therapy in individuals exposed to life-threatening radiation doses and effective triage tools for first responders in mass-casualty radiological incidents. Previously established animal (Mus musculus, Macaca mulatta) total-body irradiation (γ-exposure) models have evaluated a panel of radiation-responsive proteins that, together with peripheral blood cell counts, create a multiparametic dose-predictive algorithm with a threshold for detection of ~1 Gy from 1 to 7 d after exposure as well as demonstrate the acute radiation syndrome severity score systems created similar to the Medical Treatment Protocols for Radiation Accident Victims developed by Fliedner and colleagues. The authors present a further demonstration of the acute radiation sickness severity score system in a mouse (CD2F1, males) TBI model (1-14 Gy, Co γ-rays at 0.6 Gy min) based on multiple biodosimetric endpoints. This includes the acute radiation sickness severity Observational Grading System, survival rate, weight changes, temperature, peripheral blood cell counts and radiation-responsive protein expression profile: Flt-3 ligand, interleukin 6, granulocyte-colony stimulating factor, thrombopoietin, erythropoietin, and serum amyloid A. Results show that use of the multiple-parameter severity score system facilitates identification of animals requiring enhanced monitoring after irradiation and that proteomics are a complementary approach to conventional biodosimetry for early assessment of radiation exposure, enhancing accuracy and discrimination index for acute radiation sickness response categories and early prediction of outcome.

  11. Exploiting direct and indirect methods for the detection of the total carotenoid content in dried pasta

    NARCIS (Netherlands)

    Doka, O.; Bicanic, D.D.; Végvári, G.; Buijnsters, J.G.; Spruijt, R.B.; Luterotti, S.

    2010-01-01

    The total carotenoid concentration (TCC) of several commercially available dried pastas prepared with or without eggs was assessed by means of the two well-established destructive approaches [spectrophotometry (SP) and high-performance liquid chromatography (HPLC)] and three non-destructive, direct

  12. Direct and correlated responses to selection for total weight of lamb ...

    African Journals Online (AJOL)

    Unknown

    productivity and that each of these components can be used as a selection criterion, as each has a direct impact on total ewe ... of lamb weaned per ewe joined is more efficient than selection for number of lambs born, number of lambs weaned or weaning ... The estimated grazing capacity is 5.5 ha per small stock unit.

  13. Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

    International Nuclear Information System (INIS)

    Martin, K.E.; Gauthier, M.K.; Coss, J.R.; Dantas, A.R.V.; Price, W.E.

    1986-05-01

    Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose

  14. Total radiation dosage from X-ray examinations in rheumatoid arthritis and other chronic skeletal diseases

    International Nuclear Information System (INIS)

    Baldursson, H.; Gustafsson, M.

    1977-01-01

    Young patients with rheumatoid arthritis and other chronic diseases of the skeleton are increasingly being operated on with replacement of major joints. The great number of associated X-ray examinations performed on these patients has caused some anxiety amongst orthopaedic surgeons. Two patients with juvenile rheumatoid arthritis have been studied. An attempt was made to calculate the total radiation dose to bone marrow and gonads. For lack of recommendations for the maximum permissible radiation dose to patients, the dose calculated has been compared with the maximum permissible dose of radiation workers, and with the dose limit for non-occupational irradiation of individuals. The yearly absorbed dose in these two patients is much lower than the maximum permissible dose of radiation workers and only slightly higher than the dose limit for non-occupational exposure of individuals. (author)

  15. Direct and semi-direct aerosol radiative effect on the Mediterranean climate variability using a coupled regional climate system model

    Science.gov (United States)

    Nabat, Pierre; Somot, Samuel; Mallet, Marc; Sevault, Florence; Chiacchio, Marc; Wild, Martin

    2015-02-01

    A fully coupled regional climate system model (CNRM-RCSM4) has been used over the Mediterranean region to investigate the direct and semi-direct effects of aerosols, but also their role in the radiation-atmosphere-ocean interactions through multi-annual ensemble simulations (2003-2009) with and without aerosols and ocean-atmosphere coupling. Aerosols have been taken into account in CNRM-RCSM4 through realistic interannual monthly AOD climatologies. An evaluation of the model has been achieved, against various observations for meteorological parameters, and has shown the ability of CNRM-RCSM4 to reproduce the main patterns of the Mediterranean climate despite some biases in sea surface temperature (SST), radiation and cloud cover. The results concerning the aerosol radiative effects show a negative surface forcing on average because of the absorption and scattering of the incident radiation. The SW surface direct effect is on average -20.9 Wm-2 over the Mediterranean Sea, -14.7 Wm-2 over Europe and -19.7 Wm-2 over northern Africa. The LW surface direct effect is weaker as only dust aerosols contribute (+4.8 Wm-2 over northern Africa). This direct effect is partly counterbalanced by a positive semi-direct radiative effect over the Mediterranean Sea (+5.7 Wm-2 on average) and Europe (+5.0 Wm-2) due to changes in cloud cover and atmospheric circulation. The total aerosol effect is consequently negative at the surface and responsible for a decrease in land (on average -0.4 °C over Europe, and -0.5 °C over northern Africa) and sea surface temperature (on average -0.5 °C for the Mediterranean SST). In addition, the latent heat loss is shown to be weaker (-11.0 Wm-2) in the presence of aerosols, resulting in a decrease in specific humidity in the lower troposphere, and a reduction in cloud cover and precipitation. Simulations also indicate that dust aerosols warm the troposphere by absorbing solar radiation, and prevent radiation from reaching the surface, thus

  16. Direct aperture optimization for online adaptive radiation therapy

    International Nuclear Information System (INIS)

    Mestrovic, Ante; Milette, Marie-Pierre; Nichol, Alan; Clark, Brenda G.; Otto, Karl

    2007-01-01

    This paper is the first investigation of using direct aperture optimization (DAO) for online adaptive radiation therapy (ART). A geometrical model representing the anatomy of a typical prostate case was created. To simulate interfractional deformations, four different anatomical deformations were created by systematically deforming the original anatomy by various amounts (0.25, 0.50, 0.75, and 1.00 cm). We describe a series of techniques where the original treatment plan was adapted in order to correct for the deterioration of dose distribution quality caused by the anatomical deformations. We found that the average time needed to adapt the original plan to arrive at a clinically acceptable plan is roughly half of the time needed for a complete plan regeneration, for all four anatomical deformations. Furthermore, through modification of the DAO algorithm the optimization search space was reduced and the plan adaptation was significantly accelerated. For the first anatomical deformation (0.25 cm), the plan adaptation was six times more efficient than the complete plan regeneration. For the 0.50 and 0.75 cm deformations, the optimization efficiency was increased by a factor of roughly 3 compared to the complete plan regeneration. However, for the anatomical deformation of 1.00 cm, the reduction of the optimization search space during plan adaptation did not result in any efficiency improvement over the original (nonmodified) plan adaptation. The anatomical deformation of 1.00 cm demonstrates the limit of this approach. We propose an innovative approach to online ART in which the plan adaptation and radiation delivery are merged together and performed concurrently--adaptive radiation delivery (ARD). A fundamental advantage of ARD is the fact that radiation delivery can start almost immediately after image acquisition and evaluation. Most of the original plan adaptation is done during the radiation delivery, so the time spent adapting the original plan does not

  17. Research on the method of establishing the total radiation meter calibration device

    Science.gov (United States)

    Gao, Jianqiang; Xia, Ming; Xia, Junwen; Zhang, Dong

    2015-10-01

    Pyranometer is an instrument used to measure the solar radiation, according to pyranometer differs as installation state, can be respectively measured total solar radiation, reflected radiation, or with the help of shading device for measuring scattering radiation. Pyranometer uses the principle of thermoelectric effect, inductive element adopts winding plating type multi junction thermopile, its surface is coated with black coating with high absorption rate. Hot junction in the induction surface, while the cold junction is located in the body, the cold and hot junction produce thermoelectric potential. In the linear range, the output signal is proportional to the solar irradiance. Traceability to national meteorological station, as the unit of the national legal metrology organizations, the responsibility is to transfer value of the sun and the earth radiation value about the national meteorological industry. Using the method of comparison, with indoor calibration of solar simulator, at the same location, standard pyranometer and measured pyranometer were alternately measured radiation irradiance, depending on the irradiation sensitivity standard pyranometer were calculated the radiation sensitivity of measured pyranometer. This paper is mainly about the design and calibration method of the pyranometer indoor device. The uncertainty of the calibration result is also evaluated.

  18. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    International Nuclear Information System (INIS)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor; Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette

    2017-01-01

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D mean ), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D mean was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m 2 , with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D mean exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [de

  19. Passive-solar directional-radiating cooling system

    Science.gov (United States)

    Hull, J.R.; Schertz, W.W.

    1985-06-27

    A radiative cooling system for use with an ice-making system having a radiating surface aimed at the sky for radiating energy at one or more wavelength bands for which the atmosphere is transparent and a cover thermally isolated from the radiating surface and transparent at least to the selected wavelength or wavelengths, the thermal isolation reducing the formation of condensation on the radiating surface and/or cover and permitting the radiation to continue when the radiating surface is below the dewpoint of the atmosphere, and a housing supporting the radiating surface, cover and heat transfer means to an ice storage reservoir.

  20. Direct radiative forcing due to aerosols in Asia during March 2002.

    Science.gov (United States)

    Park, Soon-Ung; Jeong, Jaein I

    2008-12-15

    The Asian dust aerosol model (ADAM) and the aerosol dynamic model including the gas-aerosol interaction processes together with the Column Radiation Model (CRM) of Community Climate Model 3 and the output of the fifth generation of meso-scale model (MM5) in a grid 60 x 60 km2 in the Asian domain (70-150E, Equator-50N) have been employed to estimate direct radiative forcing of the Asian dust and the anthropogenic aerosols including the BC, OC, secondary inorganic aerosol (SIA), mixed type aerosol (dust+BC+OC+SIA) and sea salt aerosols at the surface, the top of atmosphere (TOA) and in the atmosphere for the period of 1-31 March 2002 during which a severe Asian dust event has been occurred in the model domain. The results indicate that the ADAM model and the aerosol dynamic model simulate quite well the spatial and temporal distributions of the mass concentration of aerosols with the R2 value of more than 0.7. The estimated mean total column aerosol mass in the analysis domain for the whole period is found to be about 78 mg m(-2), of which 66% and 34% are, respectively, contributed by the Asian dust aerosol and all the other anthropogenic aerosols. However, the direct radiative forcing contributed by the Asian dust aerosol is about 22% of the mean radiative forcing at the surface (-6.8 W m(-2)), about 31% at the top of atmosphere (-2.9 W m(-2)) and about 13% in the atmosphere (3.8 W m(-2)), suggesting relatively inefficient contribution of the Asian dust aerosol on the direct radiative forcing compared to the anthropogenic aerosols. The aerosol direct radiative forcing at the surface is mainly contributed by the mixed type aerosol (30%) and the SIA aerosol (25%) while at the top of atmosphere it is mainly contributed by the SIA aerosol (43%) and the Asian dust aerosol (31%) with positively (warming) contributed by BC and mixed type aerosols. The atmosphere is warmed mainly by the mixed type aerosol (55%) and the BC aerosol (26%). However, the largest radiative

  1. Direct radiative forcing due to aerosols in Asia during March 2002

    International Nuclear Information System (INIS)

    Park, Soon-Ung; Jeong, Jaein I.

    2008-01-01

    The Asian dust aerosol model (ADAM) and the aerosol dynamic model including the gas-aerosol interaction processes together with the Column Radiation Model (CRM) of Community Climate Model 3 and the output of the fifth generation of meso-scale model (MM5) in a grid 60 x 60 km 2 in the Asian domain (70-150E, Equator-50N) have been employed to estimate direct radiative forcing of the Asian dust and the anthropogenic aerosols including the BC, OC, secondary inorganic aerosol (SIA), mixed type aerosol (dust + BC + OC + SIA) and sea salt aerosols at the surface, the top of atmosphere (TOA) and in the atmosphere for the period of 1-31 March 2002 during which a severe Asian dust event has been occurred in the model domain. The results indicate that the ADAM model and the aerosol dynamic model simulate quite well the spatial and temporal distributions of the mass concentration of aerosols with the R 2 value of more than 0.7. The estimated mean total column aerosol mass in the analysis domain for the whole period is found to be about 78 mg m -2 , of which 66% and 34% are, respectively, contributed by the Asian dust aerosol and all the other anthropogenic aerosols. However, the direct radiative forcing contributed by the Asian dust aerosol is about 22% of the mean radiative forcing at the surface (- 6.8 W m -2 ), about 31% at the top of atmosphere (- 2.9 W m -2 ) and about 13% in the atmosphere (3.8 W m -2 ), suggesting relatively inefficient contribution of the Asian dust aerosol on the direct radiative forcing compared to the anthropogenic aerosols. The aerosol direct radiative forcing at the surface is mainly contributed by the mixed type aerosol (30%) and the SIA aerosol (25%) while at the top of atmosphere it is mainly contributed by the SIA aerosol (43%) and the Asian dust aerosol (31%) with positively (warming) contributed by BC and mixed type aerosols. The atmosphere is warmed mainly by the mixed type aerosol (55%) and the BC aerosol (26%). However, the largest

  2. An adaptive wavelet-network model for forecasting daily total solar-radiation

    International Nuclear Information System (INIS)

    Mellit, A.; Benghanem, M.; Kalogirou, S.A.

    2006-01-01

    The combination of wavelet theory and neural networks has lead to the development of wavelet networks. Wavelet-networks are feed-forward networks using wavelets as activation functions. Wavelet-networks have been used successfully in various engineering applications such as classification, identification and control problems. In this paper, the use of adaptive wavelet-network architecture in finding a suitable forecasting model for predicting the daily total solar-radiation is investigated. Total solar-radiation is considered as the most important parameter in the performance prediction of renewable energy systems, particularly in sizing photovoltaic (PV) power systems. For this purpose, daily total solar-radiation data have been recorded during the period extending from 1981 to 2001, by a meteorological station in Algeria. The wavelet-network model has been trained by using either the 19 years of data or one year of the data. In both cases the total solar radiation data corresponding to year 2001 was used for testing the model. The network was trained to accept and handle a number of unusual cases. Results indicate that the model predicts daily total solar-radiation values with a good accuracy of approximately 97% and the mean absolute percentage error is not more than 6%. In addition, the performance of the model was compared with different neural network structures and classical models. Training algorithms for wavelet-networks require smaller numbers of iterations when compared with other neural networks. The model can be used to fill missing data in weather databases. Additionally, the proposed model can be generalized and used in different locations and for other weather data, such as sunshine duration and ambient temperature. Finally, an application using the model for sizing a PV-power system is presented in order to confirm the validity of this model

  3. Separating the diffuse and direct component of global radiation and its implications for modeling canopy photosynthesis Part II. Calculation of canopy photosynthesis

    NARCIS (Netherlands)

    Spitters, C.J.T.

    1986-01-01

    In a preceding paper, a method was presented to estimate the diurnal courses of total, direct and diffuse radiation from total daily radiation only. In the present paper, these relations are introduced into a simulation model for daily canopy assimilation. With the assimilation—light response of

  4. The use of total detriment in radiation protection and its potential extension to other hazards

    International Nuclear Information System (INIS)

    Johnson, J.R.; Stansbury, P.S.; Selby, J.M.

    1991-10-01

    Before publication of the 1977 recommendations of the International Commission on Radiological Protection (ICRP), radiation protection standards were based on dose limits to single organs. These dose limits were only loosely linked to the expected effects in the first two generations from gonadal doses and to the risk of fatal cancer from doses to specific organs. In 1977, the ICRP recommended the use of the ''effective dose equivalent (EDE),'' which is a method of summing the doses (weighted with relative risk coefficients) to all organs and tissues, and recommended an annual limit for EDE. Since the 1977 recommendations were published, a ''total risk'' or total detriment approach has been extended to include nonfatal cancers and genetic effects for all subsequent generations, i.e., the total health detriment from low doses of ionizing radiation. This paper discusses the development of this total health detriment from ionizing radiation exposures, and explores potential methods for using it with other hazards (such as exposures to other physical agents, hazardous chemicals, and fatal and nonfatal accidents) in calculating the total detriment to a worker

  5. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A.

    1990-01-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy

  6. Radiation induced changes in plasma total protein nitrogen and urinary total nitrogen in desert rodent and albino rats subjected to dietary protein deficiency

    International Nuclear Information System (INIS)

    Roushdy, H.; El-Husseini, M.; Saleh, F.

    1986-01-01

    The effect of gamma-irradiation on plasma total protein nitrogen and urinary total nitrogen was studied in the desert rodent, psammomy obesus obesus and albino rats subjected to dietary protein deficiency. In albino rats kept on high protein diet, the radiation syndrome resulted in urine retention, while in those kept on non-protein diet, such phenomenon was recorded only with the high radiation level of 1170r. Radiation exposure to 780 and 1170r caused remarkable diuresis in psammomys obesus obesus whereas they induced significant urine retention in albino rats. The levels of plasma total protein nitrogen and urinary total nitrogen were higher in albino rats maintained on high protein diet than in those kept on non-protein diet. Radiation exposure caused an initial drop in plasma total protein nitrogen concentration, concomitant with an initial rise in total urinary nitrogen, radiation exposure of psammomys obesus obesus caused significant increase in the levels of plasma protein nitrogen and urinary total nitrogen. Psammomys obesus obesus seemed to be more affected by radiation exposure than did the albino rats

  7. Time- and dose-dependent effects of total-body ionizing radiation on muscle stem cells

    Science.gov (United States)

    Masuda, Shinya; Hisamatsu, Tsubasa; Seko, Daiki; Urata, Yoshishige; Goto, Shinji; Li, Tao-Sheng; Ono, Yusuke

    2015-01-01

    Exposure to high levels of genotoxic stress, such as high-dose ionizing radiation, increases both cancer and noncancer risks. However, it remains debatable whether low-dose ionizing radiation reduces cellular function, or rather induces hormetic health benefits. Here, we investigated the effects of total-body γ-ray radiation on muscle stem cells, called satellite cells. Adult C57BL/6 mice were exposed to γ-radiation at low- to high-dose rates (low, 2 or 10 mGy/day; moderate, 50 mGy/day; high, 250 mGy/day) for 30 days. No hormetic responses in proliferation, differentiation, or self-renewal of satellite cells were observed in low-dose radiation-exposed mice at the acute phase. However, at the chronic phase, population expansion of satellite cell-derived progeny was slightly decreased in mice exposed to low-dose radiation. Taken together, low-dose ionizing irradiation may suppress satellite cell function, rather than induce hormetic health benefits, in skeletal muscle in adult mice. PMID:25869487

  8. Direct analysis of biological samples by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Lue M, Marco P.; Hernandez-Caraballo, Edwin A.

    2004-01-01

    The technique of total reflection X-ray fluorescence (TXRF) is well suited for the direct analysis of biological samples due to the low matrix interferences and simultaneous multi-element nature. Nevertheless, biological organic samples are frequently analysed after digestion procedures. The direct determination of analytes requires shorter analysis time, low reactive consumption and simplifies the whole analysis process. On the other hand, the biological/clinical samples are often available in minimal amounts and routine studies require the analysis of large number of samples. To overcome the difficulties associated with the analysis of organic samples, particularly of solid ones, different procedures of sample preparation and calibration to approach the direct analysis have been evaluated: (1) slurry sampling, (2) Compton peak standardization, (3) in situ microwave digestion, (4) in situ chemical modification and (5) direct analysis with internal standardization. Examples of analytical methods developed by our research group are discussed. Some of them have not been previously published, illustrating alternative strategies for coping with various problems that may be encountered in the direct analysis by total reflection X-ray fluorescence spectrometry

  9. The review of radiation effects of γ total dose in CMOS circuits

    International Nuclear Information System (INIS)

    Chen Panxun; Gao Wenming; Xie Zeyuan; Mi Bang

    1992-01-01

    Radiation performances of commercial and rad-hard CMOS circuits are reviewed. Threshold voltage, static power current, V in -V out characteristic and propagation delay time related with total dose are presented for CMOS circuits from several manufacturing processes. The performance of radiation-annealing of experimental circuits had been observed for two years. The comparison has been made between the CMOS circuits made in China and the commercial RCA products. 60 Co γ source can serve as γ simulator of the nuclear explosion

  10. Utilisation of total solar radiation energy in the photosynthetic production of radish, red beet and bean

    Directory of Open Access Journals (Sweden)

    Wiesław Nowakowski

    2014-01-01

    Full Text Available Utilisation of total solar radiation energy in the photosynthetic production of radish, red beet and bean is expressed as per cent of solar radiation accumulated in the carbon of -the dry mass per 1 cm2 of the assimilation surface area. Utilisation of this energy ranges from 2.6 to 8.4 per cent in radish, from 1.7 to 7.5 per cent in beet and from 1.9 to 4.9 per cent in bean.

  11. Total yield of channeling radiation from relativistic electrons in thin Si and W crystals

    International Nuclear Information System (INIS)

    Abdrashitov, S.V.; Bogdanov, O.V.; Dabagov, S.B.; Pivovarov, Yu.L.; Tukhfatullin, T.A.

    2013-01-01

    Orientation dependences of channeling radiation total yield from relativistic 155–855 MeV electrons at both 〈1 0 0〉 axial and (1 0 0) planar channeling in thin silicon and tungsten crystals are studied by means of computer simulations. The model as well as computer code developed allows getting the quantitative results for orientation dependence of channeling radiation that can be used for crystal alignment in channeling experiments and/or for diagnostics of initial angular divergence of electron beam

  12. Impact of a Disposable Sterile Radiation Shield on Operator Radiation Exposure During Percutaneous Coronary Intervention of Chronic Total Occlusions.

    Science.gov (United States)

    Shorrock, Deborah; Christopoulos, Georgios; Wosik, Jedrek; Kotsia, Anna; Rangan, Bavana; Abdullah, Shuaib; Cipher, Daisha; Banerjee, Subhash; Brilakis, Emmanouil S

    2015-07-01

    Daily radiation exposure over many years can adversely impact the health of medical professionals. Operator radiation exposure was recorded for 124 percutaneous coronary interventions (PCIs) performed at our institution between August 2011 and May 2013: 69 were chronic total occlusion (CTO)-PCIs and 55 were non-CTO PCIs. A disposable radiation protection sterile drape (Radpad; Worldwide Innovations & Technologies, Inc) was used in all CTO-PCI cases vs none of the non-CTO PCI cases. Operator radiation exposure was compared between CTO and non-CTO PCIs. Mean age was 64.6 ± 6.2 years and 99.2% of the patients were men. Compared with non-CTO PCI, patients undergoing CTO-PCI were more likely to have congestive heart failure, to be current smokers, and to have longer lesions, and less likely to have prior PCI and a saphenous vein graft target lesion. CTO-PCI cases had longer procedural time (median: 123 minutes [IQR, 85-192 minutes] vs 27 minutes [IQR, 20-44 minutes]; P<.001), fluoroscopy time (35 minutes [IQR, 19-54 minutes] vs 8 minutes [IQR, 5-16 minutes]; P<.001), number of stents placed (2.4 ± 1.5 vs 1.7 ± 0.9; P<.001), and patient air kerma radiation exposure (3.92 Gray [IQR, 2.48-5.86 Gray] vs 1.22 Gray [IQR, 0.74-1.90 Gray]; P<.001), as well as dose area product (267 Gray•cm² [IQR, 163-4.25 Gray•cm²] vs 84 Gray•cm² [IQR, 48-138 Gray•cm²]; P<.001). In spite of higher patient radiation exposure, operator radiation exposure was similar between the two groups (20 μSv [IQR, 9.5-31 μSv] vs 15 μSv [IQR, 7-23 μSv]; P=.07). Operator radiation exposure during CTO-PCI can be reduced to levels similar to less complicated cases with the use of a disposable sterile radiation protection shield.

  13. Human projected area factors for detailed direct and diffuse solar radiation analysis

    DEFF Research Database (Denmark)

    Kubaha, K.; Fiala, D.; Toftum, Jørn

    2004-01-01

    Projected area factors for individual segments of the standing and sedentary human body were modelled for both direct and diffuse solar radiation using detailed 3D geometry and radiation models. The local projected area factors with respect to direct short-wave radiation are a function of the solar...

  14. Direct Observation of Radiation Defects: Experiment and Interpretation

    International Nuclear Information System (INIS)

    Dudarev, S.L.

    2012-01-01

    Electron microscopy is arguably the only available experimental method suitable for the direct visualization of nano-scale defect structures formed under irradiation. Images of dislocation loops and point-defect clusters in crystals are usually produced using diffraction contrast methods. For relatively large defects, a combination of dynamical imaging and image contrast simulations is required for determining the nature of visible radiation defects. At the same time, density functional theory (DFT) models developed over the last decade have provided unique information about the structure of nano-scale defects produced by irradiation, including the defects that are so small that they cannot be observed in an electron microscope, and about the pathways of migration and interaction between radiation defects. DFT models, involving no experimental input parameters and being as quantitatively accurate and informative as the most advanced experimental techniques for the direct observation of defects, have created a new paradigm for the scientific investigation of radiation damage phenomena. In particular, DFT models offer new insight into the origin of temperature-dependent response of materials to irradiation, a problem of pivotal significance for applications. By combining information derived from the first-principles models for radiation defects with information derived from small-scale experimental observations it may be possible to acquire quantitative knowledge about how materials respond to irradiation and, using this knowledge, develop materials suitable for advanced applications in fission and fusion. It now appears possible to pose the question about the development of integrated fusion power plant models, combining neutron transport calculations and microscopic models for microstructural evolution of materials, for example models for ab initio prediction of helium embrittlement. Such models, based on scientific principles and quantitative data, and developed

  15. NUFFT-Based Iterative Image Reconstruction via Alternating Direction Total Variation Minimization for Sparse-View CT

    Directory of Open Access Journals (Sweden)

    Bin Yan

    2015-01-01

    Full Text Available Sparse-view imaging is a promising scanning method which can reduce the radiation dose in X-ray computed tomography (CT. Reconstruction algorithm for sparse-view imaging system is of significant importance. The adoption of the spatial iterative algorithm for CT image reconstruction has a low operation efficiency and high computation requirement. A novel Fourier-based iterative reconstruction technique that utilizes nonuniform fast Fourier transform is presented in this study along with the advanced total variation (TV regularization for sparse-view CT. Combined with the alternating direction method, the proposed approach shows excellent efficiency and rapid convergence property. Numerical simulations and real data experiments are performed on a parallel beam CT. Experimental results validate that the proposed method has higher computational efficiency and better reconstruction quality than the conventional algorithms, such as simultaneous algebraic reconstruction technique using TV method and the alternating direction total variation minimization approach, with the same time duration. The proposed method appears to have extensive applications in X-ray CT imaging.

  16. Directional Degradation of Spectralon Diffuser Under Ionizing Radiation for Calibration of Space-Based Sensors

    Science.gov (United States)

    Georgiev, G. T.; Butler, J. J.; Kowalewski, M. G.; Ding, L.

    2012-01-01

    Assessment of the effect of Vacuum Ultra Violet (VUV) irradiation on the Bidirectional Reflectance Distribution Function (BRDF) of Spectralon is presented in this paper. The sample was a 99% white Spectralon calibration standard irradiated with VUV source positioned at 60o off the irradiation direction for a total of 20 hours. The BRDF before and after VUV irradiation was measured and compared at number of wavelengths in the UV, VIS and IR. Non-isotropic directional degradation of Spectralon diffuser under ionizing radiation was detected at different BRDF measurement geometries primarily at UV spectral range. The 8o directional/hemispherical reflectance of the same sample was also measured and compared from 200nm to 2500nm. Index Terms BRDF, Reflectance, Multiangular, Spectralon, Remote Sensing

  17. Synchrotron radiation total reflection X-ray fluorescence (SR-TXRF) for evaluation of food contamination

    International Nuclear Information System (INIS)

    Vives, A.E.S.; Brienza, S.M.B.; Moreira, S.; Zucchi, O.L.A.; Nascimento Filho, V.F.

    2006-01-01

    The objective of this study was to use synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF) for the determination of metals and other elements in food available to the population in commercial establishments, in order to evaluate the risks of contamination by these products. The analyzed species were vegetables, leafy vegetables, fruits, cereal and grain. The results indicated that some species were contaminated by Cr, Cu, Zn and Pb with concentrations much higher than the reference values. (author)

  18. Total radiative width (Γγ) as a function of mass number A

    International Nuclear Information System (INIS)

    Huynh, V.D.; Barros, S. De; Chevillon, P.L.; Julien, J.; Poittevin, G. Le; Morgenstern, J.; Samour, C.

    1967-01-01

    The total radiative width Γ γ was measured accurately for a large number of nuclei. These values, which are important for reactor calculations, are difficult to determine. The fluctuations in Γ γ from resonance to resonance in the same nucleus are discussed in terms of level parity and the de-excitation scheme. The authors compare the experimental values with those predicted by theory. (author) [fr

  19. Total reflection X-ray fluorescence analysis with synchrotron radiation monochromatized by multilayer structures

    International Nuclear Information System (INIS)

    Rieder, R.; Wobrauschek, P.; Ladisich, W.; Streli, C.; Aiginger, H.; Garbe, S.; Gaul, G.; Knoechel, A.; Lechtenberg, F.

    1995-01-01

    To achieve lowest detection limits in total reflection X-ray fluorescence analysis (TXRF) synchrotron radiation has been monochromatized by a multilayer structure to obtain a relative broad energy band compared to Bragg single crystals for an efficient excitation. The energy has been set to 14 keV, 17.5 keV, 31 keV and about 55 keV. Detection limits of 20 fg and 150 fg have been achieved for Sr and Cd, respectively. ((orig.))

  20. NRC [Nuclear Regulatory Commission] TLD [thermoluminescent dosimeter] direct radiation monitoring network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1989-09-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facility sites throughout the country for the second quarter of 1989

  1. NRC TLD [thermoluminescent dosimeter] Direct Radiation Monitoring Network: Progress report, January-March 1988

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1988-06-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facility sites throughout the country for the first quarter of 1988

  2. NRC TLD direct radiation monitoring network: Progress report, April--June 1988

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1988-09-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facility sites throughout the country for the second quarter of 1988

  3. Radiation nephritis following total-body irradiation and cyclophosphamide in preparation for bone marrow transplantation

    International Nuclear Information System (INIS)

    Bergstein, J.; Andreoli, S.P.; Provisor, A.J.; Yum, M.

    1986-01-01

    Two children prepared for bone marrow transplantation with total-body irradiation and cyclophosphamide developed hypertension, microscopic hematuria, proteinuria, diminished renal function, and anemia six months after transplantation. Light microscopy of the kidneys revealed mesangial expansion, glomerular capillary wall thickening, and lumenal thrombosis. Electron microscopy demonstrated widening of the subendothelial space due to the deposition of amorphous fluffy material. In one patient, immunofluorescence microscopy revealed glomerular capillary wall deposition of fibrin and immunoglobulins. The clinical and histologic findings support the diagnosis of radiation nephritis. Patients prepared for bone marrow transplantation with total-body irradiation and cyclophosphamide should be followed closely after transplantation for the development of hypertension, proteinuria, and renal insufficiency

  4. External and internal radiation therapy: Past and future directions

    Directory of Open Access Journals (Sweden)

    Sadeghi Mahdi

    2010-01-01

    Full Text Available Cancer is a leading cause of morbidity and mortality in the modern world. Treatment modalities comprise radiation therapy, surgery, chemotherapy and hormonal therapy. Radiation therapy can be performed by using external or internal radiation therapy. However, each method has its unique properties which undertakes special role in cancer treatment, this question is brought up that: For cancer treatment, whether external radiation therapy is more efficient or internal radiation therapy one? To answer this question, we need to consider principles and structure of individual methods. In this review, principles and application of each method are considered and finally these two methods are compared with each other.

  5. Thermal radiation characteristics and direct evidence of tungsten cooling on the way to nanostructure formation on its surface

    Energy Technology Data Exchange (ETDEWEB)

    Takamura, S., E-mail: takamura@aitech.ac.jp [Faculty of Engineering, Aichi Institute of Technology, Yakusa-cho, Toyota 470-0392 (Japan); Miyamoto, T. [Faculty of Engineering, Aichi Institute of Technology, Yakusa-cho, Toyota 470-0392 (Japan); Ohno, N. [Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2013-07-15

    The physical properties of tungsten with nanostructure on its surface are investigated focusing on the thermal radiation and cooling characteristics. First, direct evidence of substantial W surface cooling has been clearly shown with use of a very thin thermocouple inserted into W target, which solves an uncertainty associated with a radiation thermometer. Second, the above measurements of W surface temperature make it possible to estimate quantitatively the total emissivity from which we may evaluate the radiative power through the Stefan–Boltzmann equation, which is very important for mitigation evaluation of a serious plasma heat load to the plasma-facing component.

  6. Thermal radiation characteristics and direct evidence of tungsten cooling on the way to nanostructure formation on its surface

    International Nuclear Information System (INIS)

    Takamura, S.; Miyamoto, T.; Ohno, N.

    2013-01-01

    The physical properties of tungsten with nanostructure on its surface are investigated focusing on the thermal radiation and cooling characteristics. First, direct evidence of substantial W surface cooling has been clearly shown with use of a very thin thermocouple inserted into W target, which solves an uncertainty associated with a radiation thermometer. Second, the above measurements of W surface temperature make it possible to estimate quantitatively the total emissivity from which we may evaluate the radiative power through the Stefan–Boltzmann equation, which is very important for mitigation evaluation of a serious plasma heat load to the plasma-facing component

  7. Directional radiative properties of anisotropic rough silicon and gold surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J.; Chen, Y.B.; Zhang, Z.M. [George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States)

    2006-11-15

    Recent studies have shown that the topography of some chemically etched microrough silicon surfaces is non-Gaussian and may be strongly anisotropic. However, the bidirectional reflectance distribution function (BRDF) of anisotropic surfaces has not been fully understood. The present study uses the Monte Carlo method to investigate the out-of-plane BRDF, multiple scattering, and the change of the polarization state upon reflection. Two ray-tracing algorithms are developed that incorporate the surface topography or slope distribution of the samples obtained by the use of an atomic force microscope. The predicted BRDFs for silicon surfaces with or without a gold coating are in reasonable agreement with the results measured using a laser scatterometer at a wavelength of 635nm. The employment of surface topographic data is indispensable to the BRDF modeling of anisotropic surfaces. While first-order scattering makes the dominant contribution to reflections from the studied surfaces, it is critical to consider the polarization state change in order to correctly predict the out-of-plane BRDF. The versatile Monte Carlo modeling tools developed through the present study help gain a better understanding of the directional radiative properties of microrough surfaces and, furthermore, will have an impact on thermal metrology in the semiconductor industry. (author)

  8. Non-Directional Radiation Spread Modeling and Non-Invasive Estimating the Radiation Scattering and Absorption Parameters in Biological Tissue

    Directory of Open Access Journals (Sweden)

    S. Yu. Makarov

    2015-01-01

    Full Text Available The article dwells on a development of new non-invasive measurement methods of optical parameters of biological tissues, which are responsible for the scattering and absorption of monochromatic radiation. It is known from the theory of radiation transfer [1] that for strongly scattering media, to which many biological tissues pertain, such parameters are parameters of diffusion approximation, as well as a scattering coefficient and an anisotropy parameter.Based on statistical modeling the paper examines a spread of non-directional radiation from a Lambert light beam with the natural polarization that illuminates a surface of the biological tissue. Statistical modeling is based on the Monte Carlo method [2]. Thus, to have the correct energy coefficient values of Fresnel reflection and transmission in simulation of such radiation by Monte Carlo method the author uses his finding that is a function of the statistical representation for the incidence of model photons [3]. The paper describes in detail a principle of fixing the power transmitted by the non-directional radiation into biological tissue [3], and the equations of a power balance in this case.Further, the paper describes the diffusion approximation of a radiation transfer theory, often used in simulation of radiation propagation in strongly scattering media and shows its application in case of fixing the power transmitted into the tissue. Thus, to represent an uneven power distribution is used an approximating expression in conditions of fixing a total input power. The paper reveals behavior peculiarities of solution on the surface of the biological tissue inside and outside of the incident beam. It is shown that the solution in the region outside of the incident beam (especially far away from it, essentially, depends neither on the particular power distribution across the surface, being a part of the tissue, nor on the refractive index of the biological tissue. It is determined only by

  9. Direct radioimmunoassay (RIA) of salivary testosterone: correlation with free and total serium testosterone

    International Nuclear Information System (INIS)

    Vittek, J.; L'Hommedieu, D.G.; Gordon, G.G.; Rappaport, S.C.; Southren, A.L.

    1985-01-01

    Simple and sensitive direct RIA for determination of salivary testosterone was developed by using RSL NOSOLVEX TM (125 1) kit produced by Radioassay System Laboratories (Carcon, California). In addition, a relationship between salivary and serum free and total testosterone concentrations was studied in randomly selected 45 healthy subjects, 5 females on oral contraceptive pills and 28 hypertensive patients on various treatment regimens. The lowest weight of testosterone detectable by the modified method was equivalent to 1 pg/ml of saliva, taking into account analytical variability. Intra- and interassay coefficients of variation were 5.09 +/- 2.7% and 8.2 +/- 5.9% respectively. Statistically significant correlations were found between salivary and serum free testosterone (r = 0.97) and salivary and serum total testosterone concentrations (r = 0.70 - 0.87). The exception to this was a group of hypertensive females in which no correlation (r = 0.14) between salivary and total serum testosterone was found. It is also of interest that, while salivary testosterone was significantly increased in subjects taking oral contraceptives and most of the hypertensive patients, the total serum testosterone concentration was in normal range. These findings suggest that the determination of salivary testosterone is a reliable method to detect changes in the concentration of available biologically active hormone in the circulation. 21 references, 4 figures, 1 table

  10. Direct Effects Of Chronic Gamma Radiation On Musa Acuminata Var. Berangan, A Local Malaysia Banana Cultivar

    International Nuclear Information System (INIS)

    Maimum Tahir; Azhar Mohamad; Rozeita Laboh; Umikalsum Mohd Bahari

    2014-01-01

    Musa acuminata var. Berangan, is a popular variety of our local banana known as Pisang Berangan. The variety is a triploid banana, use mainly for dessert and has a great value for commodity fruit crops. However, production of PisangBerangan has been threatened by diseases such as Fusarium wilt, black sigatoka, Fusarium wilt, burrowing nematodes and viral diseases like Banana streak virus, Banana bunch top virus and Banana bract mosaic virus. The scenario becoming worst as Musa has a narrow genetic background for breeding and/or selection program. The banana breeding program of edible bananas is hampered by high sterility, and very limited amounts of seeds. Mutation induction via chronic gamma radiation is an alternative ways in creating more variants for selections towards a better quality and disease tolerance. A total number of 75 samples at nursery stage (1 month) were exposed to chronic gamma radiation in Gamma Greenhouse at Malaysian Nuclear Agency for 28 weeks. The samples were accordingly arranged with distance ranging from 1 m to 15 m from gamma source (Cesium-137). Plant height and new buds were used as measurement parameters in evaluating the direct effects of the chronic gamma radiation. Results showed effective dose of chronic gamma radiation in Pisang Berangan was 20 Gy. Number of new emerging sucker was ranging from 1-3 pieces with the highest at ring-4 and ring-5. Plant height was observed ranging from 22.1 to 110.5 cm. Effects of chronic radiation were observed after 3-4 months in the GGH. The samples revealed as striking leaves, short inter node and new emergence of suckers. The objective of this work is to get a dose response for chronic gamma radiation in Pisang Berangan. As for selection of potential mutant variants, new emerging suckers were tissue cultured in segregating chimeras and to get required numbers of samples for further field evaluation. (author)

  11. Ultraviolet radiation directly induces pigment production by cultured human melanocytes

    International Nuclear Information System (INIS)

    Friedmann, P.S.; Gilchrest, B.A.

    1987-01-01

    In humans the major stimulus for cutaneous pigmentation is ultraviolet radiation (UVR). Little is known about the mechanism underlying this response, in part because of the complexity of interactions in whole epidermis. Using a recently developed culture system, human melanocytes were exposed daily to a physiologic range of UVR doses from a solar simulator. Responses were determined 24 hours after the last exposure. There was a dose-related increase in melanin content per cell and uptake of 14 C-DOPA, accompanied by growth inhibition. Cells from donors of different racial origin gave proportionately similar increases in melanin, although there were approximately tenfold differences in basal values. Light and electron microscopy revealed UVR-stimulated increases in dendricity as well as melanosome number and degree of melanization, analogous to the well-recognized melanocyte changes following sun exposure of intact skin. Similar responses were seen with Cloudman S91 melanoma cells, although this murine cell line required lower UVR dosages and fewer exposures for maximal stimulation. These data establish that UVR is capable of directly stimulating melanogenesis. Because cyclic AMP elevation has been associated in some settings with increased pigment production by cultured melanocytes, preliminary experiments were conducted to see if the effects of UVR were mediated by cAMP. Both alpha-MSH and isobutylmethylxanthine (IBMX), as positive controls, caused a fourfold increase in cAMP level in human melanocytes and/or S91 cells, but following a dose of UVR sufficient to stimulate pigment production there was no change in cAMP level up to 4 hours after exposure. Thus, it appears that the UVR-induced melanogenesis is mediated by cAMP-independent mechanisms

  12. Total dose radiation effects of pressure sensors fabricated on uni-bond-SOI materials

    International Nuclear Information System (INIS)

    Zhu Shiyang; Huang Yiping; Wang Jin; Li Anzhen; Shen Shaoqun; Bao Minhang

    2001-01-01

    Piezoresistive pressure sensors with a twin-island structure were successfully fabricated using high quality Uni-bond-SOI (On Insulator) materials. Since the piezoresistors were structured by the single crystalline silicon overlayer of the SOI wafer and were totally isolated by the buried SiO 2 , the sensors are radiation-hard. The sensitivity and the linearity of the pressure sensors keep their original values after being irradiated by 60 Co γ-rays up to 2.3 x 10 4 Gy(H 2 O). However, the offset voltage of the sensor has a slight drift, increasing with the radiation dose. The absolute value of the offset voltage deviation depends on the pressure sensor itself. For comparison, corresponding polysilicon pressure sensors were fabricated using the similar process and irradiated at the same condition

  13. Tolerance to bovine clinical mastitis: Total, direct, and indirect milk losses.

    Science.gov (United States)

    Detilleux, J

    2018-04-01

    The objectives of this paper were to estimate direct and indirect milk losses associated with mastitis. Indirect losses, linked to indirect tolerance, are mediated by the increase in milk somatic cell count (SCC) in response to bacterial infection. Direct losses, linked to weak direct tolerance, are not mediated by the increase in SCC. So far, studies have evaluated milk loss associated with clinical mastitis without considering both components, which may lead to biased estimates of their sum; that is, the total loss in milk. A total of 43,903 test-day records on milk and SCC from 3,716 cows and 5,858 lactations were analyzed with mediation mixed models and health trajectories to estimate the amount of direct, indirect, and total milk losses after adjustment for known and potentially unmeasured (sensitivity analyses) confounding factors. Estimates were formalized under the counterfactual causal theory of causation. In this study, milk losses were mostly mediated by an increase in SCC. They were highest in the first month of lactation, when SCC were highest. Milk losses were estimated at 0.5, 0.8, and 1.1 kg/d in first, second, and third and greater parity, respectively. Two phases described how changes in milk were associated with changes in SCC: on average, one occurred before and one after the day preceding the clinical diagnosis. In both phases, changes in milk were estimated at 1 mg/d per 10 3 cells/mL. After adjusting for known confounders, cow effect accounted for 20.7 and 64.2% of the variation in milk in the first and second phases, respectively. This suggests that deviations from the resilient path were highest during the second phase of inflammation and that selection for cows more tolerant to mastitis is feasible. As discussed herein, epigenetic regulation of macrophage polarization may contribute to the variation in milk observed in the second phase. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure.

    Science.gov (United States)

    Camarata, Andrew S; Switchenko, Jeffrey M; Demidenko, Eugene; Flood, Ann B; Swartz, Harold M; Ali, Arif N

    2016-04-01

    Current radiation disaster manuals list the time-to-emesis (TE) as the key triage indicator of radiation dose. The data used to support TE recommendations were derived primarily from nearly instantaneous, high dose-rate exposures as part of variable condition accident databases. To date, there has not been a systematic differentiation between triage dose estimates associated with high and low dose rate (LDR) exposures, even though it is likely that after a nuclear detonation or radiologic disaster, many surviving casualties would have received a significant portion of their total exposure from fallout (LDR exposure) rather than from the initial nuclear detonation or criticality event (high dose rate exposure). This commentary discusses the issues surrounding the use of emesis as a screening diagnostic for radiation dose after LDR exposure. As part of this discussion, previously published clinical data on emesis after LDR total body irradiation (TBI) is statistically re-analyzed as an illustration of the complexity of the issue and confounding factors. This previously published data includes 107 patients who underwent TBI up to 10.5 Gy in a single fraction delivered over several hours at 0.02 to 0.04 Gy min. Estimates based on these data for the sensitivity of emesis as a screening diagnostic for the low dose rate radiation exposure range from 57.1% to 76.6%, and the estimates for specificity range from 87.5% to 99.4%. Though the original data contain multiple confounding factors, the evidence regarding sensitivity suggests that emesis appears to be quite poor as a medical screening diagnostic for LDR exposures.

  15. Sensitivity analysis of numerical weather prediction radiative schemes to forecast direct solar radiation over Australia

    Science.gov (United States)

    Mukkavilli, S. K.; Kay, M. J.; Taylor, R.; Prasad, A. A.; Troccoli, A.

    2014-12-01

    The Australian Solar Energy Forecasting System (ASEFS) project requires forecasting timeframes which range from nowcasting to long-term forecasts (minutes to two years). As concentrating solar power (CSP) plant operators are one of the key stakeholders in the national energy market, research and development enhancements for direct normal irradiance (DNI) forecasts is a major subtask. This project involves comparing different radiative scheme codes to improve day ahead DNI forecasts on the national supercomputing infrastructure running mesoscale simulations on NOAA's Weather Research & Forecast (WRF) model. ASEFS also requires aerosol data fusion for improving accurate representation of spatio-temporally variable atmospheric aerosols to reduce DNI bias error in clear sky conditions over southern Queensland & New South Wales where solar power is vulnerable to uncertainities from frequent aerosol radiative events such as bush fires and desert dust. Initial results from thirteen years of Bureau of Meteorology's (BOM) deseasonalised DNI and MODIS NASA-Terra aerosol optical depth (AOD) anomalies demonstrated strong negative correlations in north and southeast Australia along with strong variability in AOD (~0.03-0.05). Radiative transfer schemes, DNI and AOD anomaly correlations will be discussed for the population and transmission grid centric regions where current and planned CSP plants dispatch electricity to capture peak prices in the market. Aerosol and solar irradiance datasets include satellite and ground based assimilations from the national BOM, regional aerosol researchers and agencies. The presentation will provide an overview of this ASEFS project task on WRF and results to date. The overall goal of this ASEFS subtask is to develop a hybrid numerical weather prediction (NWP) and statistical/machine learning multi-model ensemble strategy that meets future operational requirements of CSP plant operators.

  16. Effects of gamma radiation on total phenolics, trypsin and tannin inhibitors in soybean grains

    Science.gov (United States)

    de Toledo, T. C. F.; Canniatti-Brazaca, S. G.; Arthur, V.; Piedade, S. M. S.

    2007-10-01

    The objective was determining possible radiation-induced alterations (with doses of 2, 4 and 8 kGy) in raw or cooked grains from five soybean cultivars through the analysis of some antinutrient. Total phenolic ranged from 2.46 to 10.83 mg/g, the trypsin inhibited from 18.19 to 71.64 UTI/g and tannins from 0.01 to 0.39 mg/g. All the antinutrient studied underwent reduction with increases in the doses and cooking process was effective too.

  17. Effects of gamma radiation on total phenolics, trypsin and tannin inhibitors in soybean grains

    International Nuclear Information System (INIS)

    de Toledo, T.C.F; Canniatti-Brazaca, S.G.; Arthur, V.; Piedade, S.M.S.

    2007-01-01

    The objective was determining possible radiation-induced alterations (with doses of 2, 4 and 8 kGy) in raw or cooked grains from five soybean cultivars through the analysis of some antinutrient. Total phenolic ranged from 2.46 to 10.83 mg/g, the trypsin inhibited from 18.19 to 71.64 UTI/g and tannins from 0.01 to 0.39 mg/g. All the antinutrient studied underwent reduction with increases in the doses and cooking process was effective too

  18. Effects of gamma radiation on total phenolics, trypsin and tannin inhibitors in soybean grains

    Energy Technology Data Exchange (ETDEWEB)

    de Toledo, T.C.F [Department of Agroindustry, Food and Nutrition Escola Superior de Agricultura ' Luiz de Queiroz' , Universidade de Sao Paulo (ESALQ/USP), Piracicaba, SP (Brazil)]. E-mail: tcftoled@esalq.usp.br; Canniatti-Brazaca, S.G. [Department of Agroindustry, Food and Nutrition, Escola Superior de Agricultura ' Luiz de Queiroz' , Universidade de Sao Paulo (ESALQ/USP), Av. Padua Dias, 11 Box 9, CEP 13418-900, Piracicaba, SP (Brazil)]. E-mail: sgcbraza@esalq.usp.br; Arthur, V. [Food Irradiation and Entomology Laboratory, Center for Nuclear Agriculture-CENA/USP, Av. Centenario 303, Caixa Postal 96, 13400-970, Piracicaba, SP (Brazil)]. E-mail: arthur@cena.usp.br; Piedade, S.M.S. [Department of Mathematic Sciences, Escola Superior de Agricultura ' Luiz de Queiroz' , Universidade de Sao Paulo (ESALQ/USP), Piracicaba, SP (Brazil)]. E-mail: soniamsp@esalq.usp.br

    2007-10-15

    The objective was determining possible radiation-induced alterations (with doses of 2, 4 and 8 kGy) in raw or cooked grains from five soybean cultivars through the analysis of some antinutrient. Total phenolic ranged from 2.46 to 10.83 mg/g, the trypsin inhibited from 18.19 to 71.64 UTI/g and tannins from 0.01 to 0.39 mg/g. All the antinutrient studied underwent reduction with increases in the doses and cooking process was effective too.

  19. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiotherapy and Radiooncology, Muenster (Germany); Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette [University Hospital of Muenster, Department of Phoniatrics and Pediatric Audiology, Muenster (Germany)

    2017-11-15

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D{sub mean}), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D{sub mean} was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m{sup 2}, with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D{sub mean} exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [German] Analyse von Inzidenz und Schweregrad einer sensorineuralen Schwerhoerigkeit (''sensorineural hearing loss'', SNHL) infolge der Wirkung unterschiedlicher Bestrahlungstechniken, Fraktionierungen, mittlerer

  20. Novel Fourier-based iterative reconstruction for sparse fan projection using alternating direction total variation minimization

    International Nuclear Information System (INIS)

    Jin Zhao; Zhang Han-Ming; Yan Bin; Li Lei; Wang Lin-Yuan; Cai Ai-Long

    2016-01-01

    Sparse-view x-ray computed tomography (CT) imaging is an interesting topic in CT field and can efficiently decrease radiation dose. Compared with spatial reconstruction, a Fourier-based algorithm has advantages in reconstruction speed and memory usage. A novel Fourier-based iterative reconstruction technique that utilizes non-uniform fast Fourier transform (NUFFT) is presented in this work along with advanced total variation (TV) regularization for a fan sparse-view CT. The proposition of a selective matrix contributes to improve reconstruction quality. The new method employs the NUFFT and its adjoin to iterate back and forth between the Fourier and image space. The performance of the proposed algorithm is demonstrated through a series of digital simulations and experimental phantom studies. Results of the proposed algorithm are compared with those of existing TV-regularized techniques based on compressed sensing method, as well as basic algebraic reconstruction technique. Compared with the existing TV-regularized techniques, the proposed Fourier-based technique significantly improves convergence rate and reduces memory allocation, respectively. (paper)

  1. Can a tachyon emit light radiation in all directions

    Energy Technology Data Exchange (ETDEWEB)

    Ramanujam, G A [NGM Coll., Tamil Nadu (India). Dept. of Physics

    1976-03-01

    It is shown here that a critical analysis of the approaches employed by various authors to accommodate tachyons into special relativity leads one to the conclusion that a tachyon can emit light radiation only along its line of motion.

  2. Studies of diffuse and direct solar radiation over snow

    International Nuclear Information System (INIS)

    Wesely, M.L.; Everett, R.G.

    1976-01-01

    Two interesting questions can be addressed by examination of solar radiation records obtained while the surface is covered with snow. One concerns the extent to which airborne particulate matter affects solar radiation received at the surface during winter conditions that are typical of those in the northeastern quarter of the United States. The other relates to the importance of complicated light scatterng in the earth-atmosphere system when the surface albedo is large. With the snow surface reflecting 50% or more of the incident radiation, it is likely that a significant addition to diffuse radiation would result from light that is reflected from the surface and then scattered back to the earth by the atmosphere. Preliminary data from measurements made during the winter of 1975 to 1976 are reported

  3. Total and Direct Correlation Function Integrals from Molecular Simulation of Binary Systems

    DEFF Research Database (Denmark)

    Wedberg, Nils Hejle Rasmus Ingemar; O’Connell, John P.; Peters, Günther H.J.

    2011-01-01

    The possibility for obtaining derivative properties for mixtures from integrals of spatial total and direct correlation functions obtained from molecular dynamics simulations is explored. Theoretically well-supported methods are examined to extend simulation radial distribution functions to long...... are consistent with an excess Helmholtz energy model fitted to available simulations. In addition, simulations of water/methanol and water/t-butanol mixtures have been carried out. The method yields results for partial molar volumes, activity coefficient derivatives, and individual correlation function integrals...... in reasonable agreement with smoothed experimental data. The proposed method for obtaining correlation function integrals is shown to perform at least as well as or better than two previously published approaches....

  4. Direct EUV/X-Ray Modulation of the Ionosphere During the August 2017 Total Solar Eclipse

    Science.gov (United States)

    Mrak, Sebastijan; Semeter, Joshua; Drob, Douglas; Huba, J. D.

    2018-05-01

    The great American total solar eclipse of 21 August 2017 offered a fortuitous opportunity to study the response of the atmosphere and ionosphere using a myriad of ground instruments. We have used the network of U.S. Global Positioning System receivers to examine perturbations in maps of ionospheric total electron content (TEC). Coherent large-scale variations in TEC have been interpreted by others as gravity wave-induced traveling ionospheric disturbances. However, the solar disk had two active regions at that time, one near the center of the disk and one at the edge, which resulted in an irregular illumination pattern in the extreme ultraviolet (EUV)/X-ray bands. Using detailed EUV occultation maps calculated from the National Aeronautics and Space Administration Solar Dynamics Observatory Atmospheric Imaging Assembly images, we show excellent agreement between TEC perturbations and computed gradients in EUV illumination. The results strongly suggest that prominent large-scale TEC disturbances were consequences of direct EUV modulation, rather than gravity wave-induced traveling ionospheric disturbances.

  5. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    Energy Technology Data Exchange (ETDEWEB)

    Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria)]. E-mail: streli@ati.ac.at; Pepponi, G. [ITC-irst, Povo (Italy); Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Jokubonis, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, D-22603 Hamburg (Germany); Zaray, G. [Institute of Inorganic and Applied Chemistry, 3 EOTVOS Univ, Budapest (Hungary); Broekaert, J. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Fittschen, U. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Peschel, B. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)

    2006-11-15

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm{sup 2} active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm{sup 2} silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al{sub 2}O{sub 3}. No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are

  6. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    International Nuclear Information System (INIS)

    Streli, C.; Pepponi, G.; Wobrauschek, P.; Jokubonis, C.; Falkenberg, G.; Zaray, G.; Broekaert, J.; Fittschen, U.; Peschel, B.

    2006-01-01

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm 2 active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm 2 silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al 2 O 3 . No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are reported. Detection

  7. Measurements of Nitrogen Dioxide Total Column Amounts using a Brewer Double Spectrophotometer in Direct Sun Mode

    Science.gov (United States)

    Cede, Alexander; Herman, Jay; Richter, Andreas; Krotkov, Nickolay; Burrows, John

    2006-01-01

    NO2 column amounts were measured for the past 2 years at Goddard Space Flight Center, Greenbelt, Maryland, using a Brewer spectrometer in direct Sun mode. A new bootstrap method to calibrate the instrument is introduced and described. This technique selects the cleanest days from the database to obtain the solar reference spectrum. The main advantage for direct Sun measurements is that the conversion uncertainty from slant column to vertical column is negligible compared to the standard scattered light observations where it is typically on the order of 100% (2sigma) at polluted sites. The total 2sigma errors of the direct Sun retrieved column amounts decrease with solar zenith angle and are estimated at 0.2 to 0.6 Dobson units (DU, 1 DU approx. equal to 2.7 10(exp 16) molecules cm(exp -2)), which is more accurate than scattered light measurements for high NO2 amounts. Measured NO2 column amounts, ranging from 0 to 3 DU with a mean of 0.7 DU, show a pronounced daily course and a strong variability from day to day. The NO2 concentration typically increases from sunrise to noon. In the afternoon it decreases in summer and stays constant in winter. As expected from the anthropogenic nature of its source, NO2 amounts on weekends are significantly reduced. The measurements were compared to satellite retrievals from Scanning Image Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY). Satellite data give the same average NO2 column and show a seasonal cycle that is similar to the ground data in the afternoon. We show that NO2 must be considered when retrieving aerosol absorption properties, especially for situations with low aerosol optical depth.

  8. Association of Radon Background and Total Background Ionizing Radiation with Alzheimer's Disease Deaths in U.S. States.

    Science.gov (United States)

    Lehrer, Steven; Rheinstein, Peter H; Rosenzweig, Kenneth E

    2017-01-01

    Exposure of the brain to ionizing radiation might promote the development of Alzheimer's disease (AD). Analysis of AD death rates versus radon background radiation and total background radiation in U.S. states. Total background, radon background, cosmic and terrestrial background radiation measurements are from Assessment of Variations in Radiation Exposure in the United States and Report No. 160 - Ionizing Radiation Exposure of the Population of the United States. 2013 AD death rates by U.S. state are from the Alzheimer's Association. Radon background ionizing radiation was significantly correlated with AD death rate in 50 states and the District of Columbia (r = 0.467, p = 0.001). Total background ionizing radiation was also significantly correlated with AD death rate in 50 states and the District of Columbia (r = 0.452, p = 0.001). Multivariate linear regression weighted by state population demonstrated that AD death rate was significantly correlated with radon background (β= 0.169, p ionizing radiation is a risk factor for AD. Intranasal inhalation of radon gas could subject the rhinencephalon and hippocampus to damaging radiation that initiates AD. The damage would accumulate over time, causing age to be a powerful risk factor.

  9. Future directions in therapy of whole body radiation injury

    Energy Technology Data Exchange (ETDEWEB)

    Cronkite, E.P.

    1989-01-01

    Clinicians have long known that marked granulocytopenia predisposed patients to bacterial infections either from pathogens or commensal organisms with which an individual usually lives in harmony. Evidence that infection was of major importance derives from several observations: (a) clinical observations of bacterial infection in human beings exposed to atomic bomb radiation in Hiroshima and Nagasaki, in reactor accidents, and in large animals dying from radiation exposure, (b) correlative studies on mortality rate, time of death, and incidence of positive culture in animals, (c) challenge of irradiated animals with normally non-virulent organisms, (d) studies of germ free mice and rats, and (e) studies of the effectiveness of antibiotics in reducing mortality rate. General knowledge and sound experimental data on animals and man clearly demonstrated that the sequelae of pancytopenia (bacterial infection, thrombopenic hemorrhage, and anemia) are the lethal factors. A lot of research was required to demonstrate that there were no mysterious radiations toxins, that hyperheparinemia was not a cause of radiation hemorrhage and that radiation hemorrhage could be prevented by fresh platelet transfusions.

  10. Future directions in therapy of whole body radiation injury

    International Nuclear Information System (INIS)

    Cronkite, E.P.

    1989-01-01

    Clinicians have long known that marked granulocytopenia predisposed patients to bacterial infections either from pathogens or commensal organisms with which an individual usually lives in harmony. Evidence that infection was of major importance derives from several observations: (a) clinical observations of bacterial infection in human beings exposed to atomic bomb radiation in Hiroshima and Nagasaki, in reactor accidents, and in large animals dying from radiation exposure, (b) correlative studies on mortality rate, time of death, and incidence of positive culture in animals, (c) challenge of irradiated animals with normally non-virulent organisms, (d) studies of germ free mice and rats, and (e) studies of the effectiveness of antibiotics in reducing mortality rate. General knowledge and sound experimental data on animals and man clearly demonstrated that the sequelae of pancytopenia (bacterial infection, thrombopenic hemorrhage, and anemia) are the lethal factors. A lot of research was required to demonstrate that there were no mysterious radiations toxins, that hyperheparinemia was not a cause of radiation hemorrhage and that radiation hemorrhage could be prevented by fresh platelet transfusions

  11. Conception and activity directions of journal ''Nuclear and radiation safety''

    International Nuclear Information System (INIS)

    Olena, M.; Volodymyr, S.

    2000-01-01

    In connection with the State Scientific and Technical Centre onr Nuclear and Radiation Safety (SSTC NRA) and Odessa State Polytechnic University the journal 'Nuclear and Radiation Safety' was established in 1998. In Ukraine many people are interested in nuclear energy problems. The accident in Chernobyl NPP unit 4 touches all Ukrainians and brings about strong and regular attention to nuclear and radiation safety of nuclear installations and nuclear technology, on the other side more than 50 per cent of electric power is produced in 5 NPPs and as following national power supply depends on stability of NPPs work. Main goals of the journal are: Support to Nuclear Regulatory Administration (NRA) of MEPNS of Ukraine, creation of information space for effective exchange of results of scientific, scientific and technical, scientific and analytical work in the field of Nuclear and Radiation Safety, assistance in integrated development of research for Nuclear and Radiation Safety by publication in a single issue of scientific articles, involvement of state scientific potential in resolving actual problems, participation in international collaboration in the framework of agreements, programs and plans. (orig.)

  12. Analysis of directional radiative behavior and heating efficiency for a gas-fired radiant burner

    International Nuclear Information System (INIS)

    Li, B.X.; Lu, Y.P.; Liu, L.H.; Kudo, K.; Tan, H.P.

    2005-01-01

    For the purpose of energy conservation and uniform heating of object surface, a gas-fired porous radiant burner with a bundle of reflecting tubes is developed. A physical model is developed to simulate the directional radiative behavior of this heating device, in which the Monte Carlo method based on the concept of radiation distribution factor is used to compute the directional radiative behavior. The effects of relating parameters on the directional behavior of radiative heating and the heating efficiency are analyzed. With the increase of the length-to-radius ratio of tube, the radiation heating efficiency decreases, but the radiation energy incident on the object surface is more collimated. The radiation heating efficiency increases with the specular reflectivity. With the increase in length of tube segment with specular reflective surface, the radiation heating efficiency increases, but the extent of concentration and collimation of radiative energy decreases. For real design of the heating device, some trade-offs are needed to balance the radiation heating efficiency and the uniformity of radiative heating of object surface

  13. An interpretation of Jupiter's decametric radiation and the terrestrial kilometric radiation as direct amplified gyroemission

    International Nuclear Information System (INIS)

    Melrose, D.B.

    1976-01-01

    Electron streams precipitating from a planetary magnetosphere can cause gyroemission in the x-mode to be amplified provided the following conditions are satisfied: (a) β/sub perpendicular/ 0 2 > approx. β/sub parallel/ 0 and, (b) abs. value β/sub s/ > f/sub p/ 2 /f/sub b/ 2 , where β/sub s/c, β/sub perpendicular/ 0 , and β/sub parallel/ 0 2 c 2 are the mean parallel velocity and the mean square perpendicular and parallel velocity spreads, respectively, and where f/sub p/ and f/sub B/ are the plasma frequency and the electron cyclotron frequency, respectively. The required anisotropy β/sub perpendicular/ 0 2 approx. > β/sub parallel/ 0 is assumed to be set up through the betatron effect, i.e., due to the stream propagating in the direction of increasing magnetic induction B. The back-reaction of the amplified emission on the stream causes β/sub perpendicular/ 0 2 to decrease. A steady state is set up with the anisotropy maintained near the threshold value β/sub perpendicular/ 0 2 approx. =β/sub parallel/ 0 , and with the excess perpendicular energy, which is gained through the betatron effect, transferred to the escaping radiation.This mechanism can account for the gross features of Jupiter's decametric emission (DAM) and for its terrestrial counterpart, the auroral kilometric radiation (AKR). The required number density in the precipitating electrons is n 1 > approx. 20 cm -3 for DAM and n 1 > approx. 2 cm -3 for AKR. Most of the power in DAM at higher frequencies ( > approx. 20MHz) is directed to higher latitudes and is not seen from the Earth. The polarization of DAM and the ray paths in the Jovian magnetosphere are discussed. The observed characteristics of ''inverted V'' auroral electron precipitation events, which correlate with AKR, appear to satisfy all the requirements of the theory. AKR should contain fine structure on a time scale approx.1μs

  14. Directional radiation pattern in structural-acoustic coupled system

    Science.gov (United States)

    Seo, Hee-Seon; Kim, Yang-Hann

    2005-07-01

    In this paper we demonstrate the possibility of designing a radiator using structural-acoustic interaction by predicting the pressure distribution and radiation pattern of a structural-acoustic coupling system that is composed by a wall and two spaces. If a wall separates spaces, then the wall's role in transporting the acoustic characteristics of the spaces is important. The spaces can be categorized as bounded finite space and unbounded infinite space. The wall considered in this study composes two plates and an opening, and the wall separates one space that is highly reverberant and the other that is unbounded without any reflection. This rather hypothetical circumstance is selected to study the general coupling problem between the finite and infinite acoustic domains. We developed an equation that predicts the energy distribution and energy flow in the two spaces separated by a wall, and its computational examples are presented. Three typical radiation patterns that include steered, focused, and omnidirected are presented. A designed radiation pattern is also presented by using the optimal design algorithm.

  15. Radiation-induced erectile dysfunction: Recent advances and future directions

    Directory of Open Access Journals (Sweden)

    Javed Mahmood, PhD

    2016-07-01

    Full Text Available Prostate cancer is one of the most prevalent cancers and the second leading cause of cancer-related deaths in men in the United States. A large number of patients undergo radiation therapy (RT as a standard care of treatment; however, RT causes erectile dysfunction (radiation-induced erectile dysfunction; RiED because of late side effects after RT that significantly affects quality of life of prostate cancer patients. Within 5 years of RT, approximately 50% of patients could develop RiED. Based on the past and current research findings and number of publications from our group, the precise mechanism of RiED is under exploration in detail. Recent investigations have shown prostate RT induces significant morphologic arterial damage with aberrant alterations in internal pudendal arterial tone. Prostatic RT also reduces motor function in the cavernous nerve which may attribute to axonal degeneration may contributing to RiED. Furthermore, the advances in radiogenomics such as radiation induced somatic mutation identification, copy number variation and genome-wide association studies has significantly facilitated identification of biomarkers that could be used to monitoring radiation-induced late toxicity and damage to the nerves; thus, genomic- and proteomic-based biomarkers could greatly improve treatment and minimize arterial tissue and nerve damage. Further, advanced technologies such as proton beam therapy that precisely target tumor and significantly reduce off-target damage to vital organs and healthy tissues. In this review, we summarize recent advances in RiED research and novel treatment modalities for RiED. We also discuss the possible molecular mechanism involved in the development of RiED in prostate cancer patients. Further, we discuss various readily available methods as well as novel strategies such as stem cell therapies, shockwave therapy, nerve grafting with tissue engineering, and nutritional supplementations might be used to

  16. Software simulation and experimental characterisation of a rotationally asymmetrical concentrator under direct and diffuse solar radiation

    International Nuclear Information System (INIS)

    Freier, Daria; Muhammad-Sukki, Firdaus; Abu-Bakar, Siti Hawa; Ramirez-Iniguez, Roberto; Abubakar Mas’ud, Abdullahi; Albarracín, Ricardo; Ardila-Rey, Jorge Alfredo; Munir, Abu Bakar; Mohd Yasin, Siti Hajar; Bani, Nurul Aini

    2016-01-01

    Highlights: • The performance of the RADTIRC was analysed under direct and diffuse radiation. • Optical gains of 4.66 under direct and 1.94 under diffuse light were achieved. • The experiments show good agreement with the simulations. • The RADTIRC is an attractive alternative for BICPV systems. - Abstract: Making housing carbon neutral is one of the European Union (EU) targets with the aim to reduce energy consumption and to increase on-site renewable energy generation in the domestic sector. Optical concentrators have a strong potential to minimise the cost of building integrated photovoltaic (BIPV) systems by replacing expensive photovoltaic (PV) material whilst maintaining the same electrical output. In this work, the performance of a recently patented optical concentrator known as the rotationally asymmetrical dielectric totally internally reflective concentrator (RADTIRC) was analysed under direct and diffuse light conditions. The RADTIRC has a geometrical concentration gain of 4.969 and two half acceptance angles of ±40° and ±30° respectively along the two axes. Simulation and experimental work has been carried out to determine the optical concentration gain and the angular response of the concentrator. It was found that the RADTIRC has an optical concentration gain of 4.66 under direct irradiance and 1.94 under diffuse irradiance. The experimental results for the single concentrator showed a reduction in concentration gain of 4.2% when compared with simulation data.

  17. Radiation closure and diurnal cycle of the clear-sky dust instantaneous direct radiative forcing over Arabian Peninsula

    KAUST Repository

    Osipov, Sergey

    2015-04-01

    To better quantify radiative effects of dust over the Arabian Peninsula we have developed a standalone column radiation transport model coupled with the Mie calculations and driven by reanalysis meteorological fields and atmospheric composition. Numerical experiments are carried out for a wide range of aerosol optical depths, including extreme values developed during the dust storm on 18-20 March 2012. Comprehensive ground-based observations and satellite retrievals are used to estimate aerosol optical properties, validate calculations and carry out radiation closure. The broadband surface albedo, fluxes at the bottom and top of the atmosphere as well as instantaneous dust radiative forcing are estimated both from the model and from observations. Diurnal cycle of the the shortwave instantaneous dust direct radiative forcing is studied for a range of aerosol and surface characteristics representative for the Arabian Peninsula. Mechanisms and parameters responsible for diurnal variability of the radiative forcing are evaluated. We found that intrinsic variability of the surface albedo and its dependence on atmospheric conditions along with anisotropic aerosol scattering are mostly responsible for diurnal effects. We also discuss estimates of the climatological dust instantaneous direct radiative forcing over land and the Red Sea using two approaches. The first approach is based on the probability density function of the aerosol optical depth, and the second is based on the climatologically average Spinning Enhanced Visible and Infrared Imager (SEVIRI) aerosol optical depth. Results are compared with Geostationary Earth Radiation Budget (GERB) derived top of the atmosphere climatological forcing over the Red Sea.

  18. Synchrotron radiation total reflection x-ray fluorescence analysis; of polymer coated silicon wafers

    International Nuclear Information System (INIS)

    Brehm, L.; Kregsamer, P.; Pianetta, P.

    2000-01-01

    It is well known that total reflection x-ray fluorescence (TXRF) provides an efficient method for analyzing trace metal contamination on silicon wafer surfaces. New polymeric materials used as interlayer dielectrics in microprocessors are applied to the surface of silicon wafers by a spin-coating process. Analysis of these polymer coated wafers present a new challenge for TXRF analysis. Polymer solutions are typically analyzed for bulk metal contamination prior to application on the wafer using inductively coupled plasma mass spectrometry (ICP-MS). Questions have arisen about how to relate results of surface contamination analysis (TXRF) of a polymer coated wafer to bulk trace analysis (ICP-MS) of the polymer solutions. Experiments were done to explore this issue using synchrotron radiation (SR) TXRF. Polymer solutions were spiked with several different concentrations of metals. These solutions were applied to silicon wafers using the normal spin-coating process. The polymer coated wafers were then measured using the SR-TXRF instrument set-up at the Stanford Synchrotron Radiation Laboratory (SSRL). Several methods of quantitation were evaluated. The best results were obtained by developing calibration curves (intensity versus ppb) using the spiked polymer coated wafers as standards. Conversion of SR-TXRF surface analysis results (atoms/cm 2 ) to a volume related concentration was also investigated. (author)

  19. Predicting the components of the total hemispherical solar radiation from sunshine duration measurements in Lagos, Nigeria

    International Nuclear Information System (INIS)

    Maduekwe, A.A.L.; Chendo, M.A.C.

    1994-06-01

    Correlations for the city of Lagos (latitude 6.58 deg. N, longitude 3.33 deg. E) have been found between the records of bright sunshine hours and the daily and monthly components of the total hemispherical solar radiation. Four new models have been developed which include H/H 0 as a predictor in the Angstrom type models for the diffuse and beam fractions. They contain the quadratic term of the sunshine index, (n/N) and are given as follows: Q/H 0 =a+b(H/H 0 )+c(n/N)+d(n/N) 2 Q/H 0 =a+b(H/H 0 )+d(n/N) 2 ; Q/H 0 =a+b(H/H 0 )+c(n/N)+d(n/N) 2 ; Q/H 0 =a+b(H/H 0 )+d(n/N) 2 ; where Q is the diffuse or beam radiation on a horizontal plane. The statistical test carried out showed that the new equations generally improved the prediction of the beam or diffuse components from the Angstrom type equations by over 25%. (author). 21 refs, 3 tabs

  20. Estimating total solar radiation in different climatological of region in Iran using cloud factor

    International Nuclear Information System (INIS)

    Jafarpour, Kh.; Karshenas, M.

    2002-01-01

    Iran is among the countries located on the belt pertaining to lands with a high rate of solar insolation. Statistics shows that, for instance, the solar energy which hi ted the Iranian contention al land just in the year of 1990, was more than 1600 times that of the energy exported by Iran in the same year. This high rate of solar insolation, on the one hand and the limitation of fossil-fuel reservoirs (specially, utilizing energy from such sources is polluting the environment) on the other hand, show that harnessing the solar energy is not anymore a choice of decision but rather on obligation. To fulfill this obligation one needs solar insolation data to be able to design and evaluate solar energy utilizing systems and other uses under different climatological conditions of Iran. As a first step, this article provides total solar radiation data for various cities in Iran under different climatological conditions using cloud factor as a parameter

  1. Multielemental analysis in Brazilian cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Serpa, Renata F.B.; Jesus, Edgar F.O. de; Lopes, Ricardo T.; Moreira, Silvana

    2005-01-01

    In order to identify major and trace elements in conventional and light Brazilian cigarettes, Total Reflection X-Ray Fluorescence with Synchrotron Radiation (SR-TXRF) was used. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. This technique enables detection limit is in the ngg -1 range, which is very useful in elemental tobacco smoke analysis, since it presents most of its elements at a trace level. The major elements identified in tobacco samples were: S, Cl, K, Ca, Mn, Fe and Cd, and the trace elements were: Ti, Cr, Ni, Cu, Zn, Br, Rb, Sr and Ba. However in tobacco smoke samples, there were only two major elements: K and Ca, the others were present a trace level. The rate transfer of tobacco to tobacco smoke was about 2.5 % for all elements studied. (author)

  2. Beer analysis by synchrotron radiation total reflection X-ray fluorescence (SR-TXRF)

    International Nuclear Information System (INIS)

    Moreira, Silvana; Vives, Ana Elisa S. de; Nascimento Filho, Virgilio F.; Zucchi, Orgheda L.D.A.

    2005-01-01

    In this work the concentrations of P, S, Cl, K, Ca, Mn, Fe, Zn and Br in twenty-nine brands of national and international beers were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF). The results were compared with the limits established by the Brazilian Legislation and the nutritive values established by National Agricultural Library (NAL). The measurements were performed at the X-ray Fluorescence Beamline at Synchrotron Light Source Laboratory, in Campinas, Sao Paulo, Brazil, using a polychromatic beam for excitation. A small volume of 5 μL of sample beers containing just an internal standard, used to correct geometry effects, were analyzed without any pre-treatment. The measuring time was 100 s and the detection limits obtained varied from 1μg.L -1 for Mn and Fe to 15μg.L -1 for P. (author)

  3. Beer analysis by synchrotron radiation total reflection X-ray fluorescence (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo. Dept. de Recursos Hidricos]. E-mail: silvana@fec.unicamp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Nascimento Filho, Virgilio F. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear]. E-mail: virgilio@cena.usp.br; Zucchi, Orgheda L.D.A. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas de Ribeirao Preto]. E-mail: olzucchi@fcfrp.usp.br

    2005-07-01

    In this work the concentrations of P, S, Cl, K, Ca, Mn, Fe, Zn and Br in twenty-nine brands of national and international beers were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF). The results were compared with the limits established by the Brazilian Legislation and the nutritive values established by National Agricultural Library (NAL). The measurements were performed at the X-ray Fluorescence Beamline at Synchrotron Light Source Laboratory, in Campinas, Sao Paulo, Brazil, using a polychromatic beam for excitation. A small volume of 5 {mu}L of sample beers containing just an internal standard, used to correct geometry effects, were analyzed without any pre-treatment. The measuring time was 100 s and the detection limits obtained varied from 1{mu}g.L{sup -1} for Mn and Fe to 15{mu}g.L{sup -1} for P. (author)

  4. NRC TLD Direct Radiation Monitoring Network. Volume 5, No. 2. Progress report, April-June 1985

    International Nuclear Information System (INIS)

    Jang, J.; Kramaric, M.; Cohen, L.

    1985-09-01

    The US Nuclear Regulatory Commission (NRC) Direct Radiation Monitoring Network provides continuous measurement of the ambient radiation levels around licensed NRC facilities, primarily power reactors. The Network is intended to measure radiation levels during routine facility operations and to establish background radiation levels used to assess the radiological impact of an unusual condition, such as an accident. This report presents the radiation levels measured around all facilities in the Network for the second quarter of 1985. A complete listing of the site facilities monitored is included

  5. Fourier-based reconstruction via alternating direction total variation minimization in linear scan CT

    International Nuclear Information System (INIS)

    Cai, Ailong; Wang, Linyuan; Yan, Bin; Zhang, Hanming; Li, Lei; Xi, Xiaoqi; Li, Jianxin

    2015-01-01

    In this study, we consider a novel form of computed tomography (CT), that is, linear scan CT (LCT), which applies a straight line trajectory. Furthermore, an iterative algorithm is proposed for pseudo-polar Fourier reconstruction through total variation minimization (PPF-TVM). Considering that the sampled Fourier data are distributed in pseudo-polar coordinates, the reconstruction model minimizes the TV of the image subject to the constraint that the estimated 2D Fourier data for the image are consistent with the 1D Fourier transform of the projection data. PPF-TVM employs the alternating direction method (ADM) to develop a robust and efficient iteration scheme, which ensures stable convergence provided that appropriate parameter values are given. In the ADM scheme, PPF-TVM applies the pseudo-polar fast Fourier transform and its adjoint to iterate back and forth between the image and frequency domains. Thus, there is no interpolation in the Fourier domain, which makes the algorithm both fast and accurate. PPF-TVM is particularly useful for limited angle reconstruction in LCT and it appears to be robust against artifacts. The PPF-TVM algorithm was tested with the FORBILD head phantom and real data in comparisons with state-of-the-art algorithms. Simulation studies and real data verification suggest that PPF-TVM can reconstruct higher accuracy images with lower time consumption

  6. Modulation of Total Sleep Time by Transcranial Direct Current Stimulation (tDCS).

    Science.gov (United States)

    Frase, Lukas; Piosczyk, Hannah; Zittel, Sulamith; Jahn, Friederike; Selhausen, Peter; Krone, Lukas; Feige, Bernd; Mainberger, Florian; Maier, Jonathan G; Kuhn, Marion; Klöppel, Stefan; Normann, Claus; Sterr, Annette; Spiegelhalder, Kai; Riemann, Dieter; Nitsche, Michael A; Nissen, Christoph

    2016-09-01

    Arousal and sleep are fundamental physiological processes, and their modulation is of high clinical significance. This study tested the hypothesis that total sleep time (TST) in humans can be modulated by the non-invasive brain stimulation technique transcranial direct current stimulation (tDCS) targeting a 'top-down' cortico-thalamic pathway of sleep-wake regulation. Nineteen healthy participants underwent a within-subject, repeated-measures protocol across five nights in the sleep laboratory with polysomnographic monitoring (adaptation, baseline, three experimental nights). tDCS was delivered via bi-frontal target electrodes and bi-parietal return electrodes before sleep (anodal 'activation', cathodal 'deactivation', and sham stimulation). Bi-frontal anodal stimulation significantly decreased TST, compared with cathodal and sham stimulation. This effect was location specific. Bi-frontal cathodal stimulation did not significantly increase TST, potentially due to ceiling effects in good sleepers. Exploratory resting-state EEG analyses before and after the tDCS protocols were consistent with the notion of increased cortical arousal after anodal stimulation and decreased cortical arousal after cathodal stimulation. The study provides proof-of-concept that TST can be decreased by non-invasive bi-frontal anodal tDCS in healthy humans. Further elucidating the 'top-down' pathway of sleep-wake regulation is expected to increase knowledge on the fundamentals of sleep-wake regulation and to contribute to the development of novel treatments for clinical conditions of disturbed arousal and sleep.

  7. Blind image fusion for hyperspectral imaging with the directional total variation

    Science.gov (United States)

    Bungert, Leon; Coomes, David A.; Ehrhardt, Matthias J.; Rasch, Jennifer; Reisenhofer, Rafael; Schönlieb, Carola-Bibiane

    2018-04-01

    Hyperspectral imaging is a cutting-edge type of remote sensing used for mapping vegetation properties, rock minerals and other materials. A major drawback of hyperspectral imaging devices is their intrinsic low spatial resolution. In this paper, we propose a method for increasing the spatial resolution of a hyperspectral image by fusing it with an image of higher spatial resolution that was obtained with a different imaging modality. This is accomplished by solving a variational problem in which the regularization functional is the directional total variation. To accommodate for possible mis-registrations between the two images, we consider a non-convex blind super-resolution problem where both a fused image and the corresponding convolution kernel are estimated. Using this approach, our model can realign the given images if needed. Our experimental results indicate that the non-convexity is negligible in practice and that reliable solutions can be computed using a variety of different optimization algorithms. Numerical results on real remote sensing data from plant sciences and urban monitoring show the potential of the proposed method and suggests that it is robust with respect to the regularization parameters, mis-registration and the shape of the kernel.

  8. Rapid, accurate, and direct determination of total lycopene content in tomato paste

    Science.gov (United States)

    Bicanic, D.; Anese, M.; Luterotti, S.; Dadarlat, D.; Gibkes, J.; Lubbers, M.

    2003-01-01

    Lycopene that imparts red color to the tomato fruit is the most potent antioxidant among carotenes, an important nutrient and also used as a color ingredient in many food formulations. Since cooked and processed foods derived from tomatoes were shown to provide optimal lycopene boost, products such as paste, puree, juice, etc. are nowadays gaining popularity as dietary sources. The analysis of lycopene in tomato paste (partially dehydrated product prepared by vacuum concentrating tomato juice) is carried out using either high pressure liquid chromatography (HPLC), spectrophotometry, or by evaluating the color. The instability of lycopene during processes of extraction, etc., handling, and disposal of organic solvents makes the preparation of a sample for the analysis a delicate task. Despite a recognized need for accurate and rapid assessment of lycopene in tomato products no such method is available at present. The study described here focuses on a direct determination of a total lycopene content in different tomato pastes by means of the laser optothermal window (LOW) method at 502 nm. The concentration of lycopene in tomato paste ranged between 25 and 150 mg per 100 g product; the results are in excellent agreement with those obtained by spectrophotometry. The time needed to complete LOW analysis is very short, so that decomposition of pigment and the formation of artifacts are minimized. Preliminary results indicate a good degree of reproducibility making the LOW method suitable for routine assays of lycopene content in tomato paste.

  9. Direct measurement of the total decay width of the top quark.

    Science.gov (United States)

    Aaltonen, T; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Butti, P; Buzatu, A; Calamba, A; Camarda, S; Campanelli, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Cho, K; Chokheli, D; Clark, A; Clarke, C; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Cremonesi, M; Cruz, D; Cuevas, J; Culbertson, R; d'Ascenzo, N; Datta, M; de Barbaro, P; Demortier, L; Deninno, M; D'Errico, M; Devoto, F; Di Canto, A; Di Ruzza, B; Dittmann, J R; Donati, S; D'Onofrio, M; Dorigo, M; Driutti, A; Ebina, K; Edgar, R; Elagin, A; Erbacher, R; Errede, S; Esham, B; Farrington, S; Fernández Ramos, J P; Field, R; Flanagan, G; Forrest, R; Franklin, M; Freeman, J C; Frisch, H; Funakoshi, Y; Galloni, C; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González López, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gramellini, E; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Han, J Y; Happacher, F; Hara, K; Hare, M; Harr, R F; Harrington-Taber, T; Hatakeyama, K; Hays, C; Heinrich, J; Herndon, M; Hocker, A; Hong, Z; Hopkins, W; Hou, S; Hughes, R E; Husemann, U; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kambeitz, M; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S H; Kim, S B; Kim, Y J; Kim, Y K; Kimura, N; Kirby, M; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Kruse, M; Kuhr, T; Kurata, M; Laasanen, A T; Lammel, S; Lancaster, M; Lannon, K; Latino, G; Lee, H S; Lee, J S; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lipeles, E; Lister, A; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lucà, A; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Marchese, L; Margaroli, F; Marino, P; Martínez, M; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Moon, C S; Moore, R; Morello, M J; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Nigmanov, T; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagliarone, C; Palencia, E; Palni, P; Papadimitriou, V; Parker, W; Pauletta, G; Paulini, M; Paus, C; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Pranko, A; Prokoshin, F; Ptohos, F; Punzi, G; Ranjan, N; Redondo Fernández, I; Renton, P; Rescigno, M; Rimondi, F; Ristori, L; Robson, A; Rodriguez, T; Rolli, S; Ronzani, M; Roser, R; Rosner, J L; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, E E; Schwarz, T; Scodellaro, L; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sliwa, K; Smith, J R; Snider, F D; Song, H; Sorin, V; St Denis, R; Stancari, M; Stentz, D; Strologas, J; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thomson, E; Thukral, V; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Vázquez, F; Velev, G; Vellidis, C; Vernieri, C; Vidal, M; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wallny, R; Wang, S M; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wilbur, S; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Zanetti, A M; Zeng, Y; Zhou, C; Zucchelli, S

    2013-11-15

    We present a measurement of the total decay width of the top quark using events with top-antitop quark pair candidates reconstructed in the final state with one charged lepton and four or more hadronic jets. We use the full Tevatron run II data set of sqrt[s]=1.96  TeV proton-antiproton collisions recorded by the CDF II detector. The top quark mass and the mass of the hadronically decaying W boson are reconstructed for each event and compared with distributions derived from simulated signal and background samples to extract the top quark width (Γtop) and the energy scale of the calorimeter jets with in situ calibration. For a top quark mass Mtop=172.5  GeV/c2, we find 1.10<Γtop<4.05  GeV at 68% confidence level, which is in agreement with the standard model expectation of 1.3 GeV and is the most precise direct measurement of the top quark width to date.

  10. Sensing methanol concentration in direct methanol fuel cell with total harmonic distortion: Theory and application

    International Nuclear Information System (INIS)

    Mao Qing; Krewer, Ulrike

    2012-01-01

    The nonlinear frequency response of a direct methanol fuel cell (DMFC) is studied by analyzing the total harmonic distortion (THD) spectra. The dependence of the THD spectra on methanol concentration and methanol oxidation kinetics is investigated by means of both simulation and experiment. Simulation using a continuous stirred tank reactor network model suggests that the methanol concentration profile in the anode has a strong impact on the THD spectra. The experimentally observed nonlinear behavior of the DMFC anode can be qualitatively reproduced with a model containing a three-step methanol oxidation mechanism with Kauranen–Frumkin/Temkin kinetics. Both experiment and simulation results show that THD value has a monotonic correlation with methanol concentration at certain frequencies and its sensitivity to concentration is improved with increased current amplitude. The monotonic relationship enables the THD to sense the methanol concentration level by the DMFC itself, which is of mayor interest for the portable application as an external sensor for the system can be omitted.

  11. Apparatuses and method for converting electromagnetic radiation to direct current

    Science.gov (United States)

    Kotter, Dale K; Novack, Steven D

    2014-09-30

    An energy conversion device may include a first antenna and a second antenna configured to generate an AC current responsive to incident radiation, at least one stripline, and a rectifier coupled with the at least one stripline along a length of the at least one stripline. An energy conversion device may also include an array of nanoantennas configured to generate an AC current in response to receiving incident radiation. Each nanoantenna of the array includes a pair of resonant elements, and a shared rectifier operably coupled to the pair of resonant elements, the shared rectifier configured to convert the AC current to a DC current. The energy conversion device may further include a bus structure operably coupled with the array of nanoantennas and configured to receive the DC current from the array of nanoantennas and transmit the DC current away from the array of nanoantennas.

  12. More on direct estimates of low-level radiation risks

    International Nuclear Information System (INIS)

    Rinsky, R.

    1982-01-01

    In an epidemiologic study of mortality at the Portsmouth Naval Shipyard (PNS), the National Institute for Occupational Safety and Health (NIOSH) found no evidence of excess deaths due to leukemia or other cancers among workers exposed to low levels of ionizing radiation. In a subsequent analysis, Bross and Driscoll identified excess lung cancer mortality in PNS workers with lifetime radiation dose of 1 rem or greater and with more than 15 years' latency since first radiation exposure. Although that observation may be important and is currently being examined through case-control analyses, it must be recognized that Bross and Driscoll extracted their observation from matrices of over 4,000 data cells apparently by recombination of innumerable possible permutations of dosage and latency intervals. For that reason, their finding can be regarded as no more than a suggestion for further study. It certainly does not represent a proper scientific conclusion. Bross and Driscoll's analysis illustrates the hazard of performing multiple statistical comparisons on complex data sets in the absence of a priori hypotheses

  13. EC-directive optical radiation - present state of consultation; EG-Richtlinie optische Strahlung - aktueller Beratungsstand

    Energy Technology Data Exchange (ETDEWEB)

    Pipke, R. [Bundesanstalt fuer Arbeitschutz und Arbeitsmedizin, Dortmund (Germany)

    2004-07-01

    The draft of a directive on the protection of workers from risks related to radiation in the range from 100 nm to 1 mm (Laser, UV-radiation) is discussed on EC-level. The European concept of regulations on occupational safety and health is outlined and put into reference with other directives on the protection against physical agents (vibrations, noise, electromagnetic fields). Building up on this the present state of consultation of a directive on optical radiation is represented, including major points of consideration. (orig.)

  14. Cancer risk estimates from radiation therapy for heterotopic ossification prophylaxis after total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Mazonakis, Michalis; Berris, Theoharris; Damilakis, John [Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, 71003 Iraklion, Crete (Greece); Lyraraki, Efrossyni [Department of Radiotherapy and Oncology, University Hospital of Iraklion, 71110 Iraklion, Crete (Greece)

    2013-10-15

    Purpose: Heterotopic ossification (HO) is a frequent complication following total hip arthroplasty. This study was conducted to calculate the radiation dose to organs-at-risk and estimate the probability of cancer induction from radiotherapy for HO prophylaxis.Methods: Hip irradiation for HO with a 6 MV photon beam was simulated with the aid of a Monte Carlo model. A realistic humanoid phantom representing an average adult patient was implemented in Monte Carlo environment for dosimetric calculations. The average out-of-field radiation dose to stomach, liver, lung, prostate, bladder, thyroid, breast, uterus, and ovary was calculated. The organ-equivalent-dose to colon, that was partly included within the treatment field, was also determined. Organ dose calculations were carried out using three different field sizes. The dependence of organ doses upon the block insertion into primary beam for shielding colon and prosthesis was investigated. The lifetime attributable risk for cancer development was estimated using organ, age, and gender-specific risk coefficients.Results: For a typical target dose of 7 Gy, organ doses varied from 1.0 to 741.1 mGy by the field dimensions and organ location relative to the field edge. Blocked field irradiations resulted in a dose range of 1.4–146.3 mGy. The most probable detriment from open field treatment of male patients was colon cancer with a high risk of 564.3 × 10{sup −5} to 837.4 × 10{sup −5} depending upon the organ dose magnitude and the patient's age. The corresponding colon cancer risk for female patients was (372.2–541.0) × 10{sup −5}. The probability of bladder cancer development was more than 113.7 × 10{sup −5} and 110.3 × 10{sup −5} for males and females, respectively. The cancer risk range to other individual organs was reduced to (0.003–68.5) × 10{sup −5}.Conclusions: The risk for cancer induction from radiation therapy for HO prophylaxis after total hip arthroplasty varies considerably by

  15. Cancer risk estimates from radiation therapy for heterotopic ossification prophylaxis after total hip arthroplasty

    International Nuclear Information System (INIS)

    Mazonakis, Michalis; Berris, Theoharris; Damilakis, John; Lyraraki, Efrossyni

    2013-01-01

    Purpose: Heterotopic ossification (HO) is a frequent complication following total hip arthroplasty. This study was conducted to calculate the radiation dose to organs-at-risk and estimate the probability of cancer induction from radiotherapy for HO prophylaxis.Methods: Hip irradiation for HO with a 6 MV photon beam was simulated with the aid of a Monte Carlo model. A realistic humanoid phantom representing an average adult patient was implemented in Monte Carlo environment for dosimetric calculations. The average out-of-field radiation dose to stomach, liver, lung, prostate, bladder, thyroid, breast, uterus, and ovary was calculated. The organ-equivalent-dose to colon, that was partly included within the treatment field, was also determined. Organ dose calculations were carried out using three different field sizes. The dependence of organ doses upon the block insertion into primary beam for shielding colon and prosthesis was investigated. The lifetime attributable risk for cancer development was estimated using organ, age, and gender-specific risk coefficients.Results: For a typical target dose of 7 Gy, organ doses varied from 1.0 to 741.1 mGy by the field dimensions and organ location relative to the field edge. Blocked field irradiations resulted in a dose range of 1.4–146.3 mGy. The most probable detriment from open field treatment of male patients was colon cancer with a high risk of 564.3 × 10 −5 to 837.4 × 10 −5 depending upon the organ dose magnitude and the patient's age. The corresponding colon cancer risk for female patients was (372.2–541.0) × 10 −5 . The probability of bladder cancer development was more than 113.7 × 10 −5 and 110.3 × 10 −5 for males and females, respectively. The cancer risk range to other individual organs was reduced to (0.003–68.5) × 10 −5 .Conclusions: The risk for cancer induction from radiation therapy for HO prophylaxis after total hip arthroplasty varies considerably by the treatment parameters, organ

  16. Inhaled /sup 147/Pm and/or total-body gamma radiation: Early mortality and morbidity in rats

    Energy Technology Data Exchange (ETDEWEB)

    Filipy, R.E.; Lauhala, K.E.; McGee, D.R.; Cannon, W.C.; Buschbom, R.L.; Decker, J.R.; Kuffel, E.G.; Park, J.F.; Ragan, H.A.; Yaniv, S.S.; Scott, B.R.

    1989-05-01

    Rats were given doses of /sup 60/Co gamma radiation and/or lung burdens of /sup 147/Pm (in fused aluminosilicate particles) within lethal ranges in an experiment to determine and compare morbidity and mortality responses for the radiation insults within 1 year after exposure. Radiation-induced morbidity was assessed by measuring changes in body weights, hematologic parameters, and pulmonary-function parameters. Acute mortality and morbidity from inhaled promethium were caused primarily by radiation pneumonitis and pulmonary fibrosis that occurred more than 53 days after exposure. Acute mortality and morbidity from total-body gamma irradiation occurred within 30 days of exposure and resulted from the bone-marrow radiation syndrome. Gamma radiation caused transient morbidity, reflected by immediately depressed blood cell levels and by reduced body weight gain in animals that survived the acute gamma radiation syndrome. Inhaled promethium caused a loss of body weight and diminished pulmonary function, but its only effect on blood cell levels was lymphocytopenia. Combined gamma irradiation and promethium lung burdens were synergistic, in that animals receiving both radiation insults had higher morbidity and mortality rates than would be predicted based on the effect of either kind of radiation alone. Promethium lung burdens enhanced the effect of gamma radiation in rats within the first 30 days of exposure, and gamma radiation enhanced the later effect of promethium lung burdens. 70 refs., 68 figs., 21 tabs.

  17. Calculation and mapping of direct and diffuse solar radiation in Costa Rica

    International Nuclear Information System (INIS)

    Wright, Jaime

    2008-01-01

    Knowledge of direct and diffuse solar radiation has been of vital importance in assessing the energy potential of Costa Rica. The work is focused on the calculation and plotting of contour maps of the direct and diffuse solar radiation, based in sixty-two radiometric stations scattered throughout the country. In tracing these contours have been used experimental and predicted values of direct and diffuse radiation. Additionally, direct and diffuse solar radiation is compared during the dry season and the rainy season in the six climatic regions of the country: Valle Central, North Pacific, Central Pacific, South Pacific, North Zone and Caribbean Region. Daily average levels of radiation observed directly have been from 6.1 and 10.1 MJ/m 2 , with higher values in the northern sections of the Pacific Slope, west of Valle Central and the tops of the highest mountains. The lowest values have coincided with the North Zone and Caribbean Region. The highest values of diffuse radiation have coincided with the North Zone and South Pacific. An increase in direct solar radiation by 40% is observed in the month of the dry season. (author) [es

  18. Measurements of integrated direct, diffuse and global ultraviolet-B radiation

    International Nuclear Information System (INIS)

    Utrillas, M.P.; Pedrós, R.; Gandía, S.; Gómez-Amo, J.L.; Estellés, V.; Martínez-Lozano, J.A.

    2015-01-01

    We present the first multiyear set of simultaneous measurements of the global ultraviolet-B radiation and its two components: direct and diffuse. The measurements have been taken with four YES-UVB-1 radiometers: two radiometers to measure the diffuse radiation, one provided with a shadow band and the other with a shadow disk on a Sun tracker; a radiometer to measure the global horizontal radiation; and a Sun-tracking radiometer to measure the direct radiation with an especially designed radiance collimator. The diffuse minute-values measured with both instruments agree within a coefficient correlation of 1.00. The diffuse component represents at least 50% of the global UVB (ultraviolet-B) radiation. The minute values of global UVB irradiance obtained by adding the direct and diffuse components concur with the measured global irradiance. Therefore, the measurement of the direct irradiance enables the estimation of the diffuse component, and gives an insight into the factors that affect its value, especially aerosols. - Highlights: • Simultaneous measurements of global, direct and diffuse UVB (ultraviolet-B) radiation. • The diffuse minute-values are at least 50% of the global ones. • The diffuse measurements are highly correlated to the aerosol load. • The sum of direct + diffuse radiation concur with the measured global.

  19. Radiation binary targeted therapy for HER-2 positive breast cancers: assumptions, theoretical assessment and future directions

    Energy Technology Data Exchange (ETDEWEB)

    Mundy, Daniel W [School of Nuclear Engineering, Purdue University, 400 Central Drive, West Lafayette, IN 47909 (United States); Harb, Wael [Horizon Oncology, The Care Group, Unity Medical Center, Lafayette, IN 47901 (United States); Jevremovic, Tatjana [School of Nuclear Engineering, Purdue University, 400 Central Drive, West Lafayette, IN 47909 (United States)

    2006-03-21

    A novel radiation targeted therapy is investigated for HER-2 positive breast cancers. The proposed concept combines two known approaches, but never used together for the treatment of advanced, relapsed or metastasized HER-2 positive breast cancers. The proposed radiation binary targeted concept is based on the anti HER-2 monoclonal antibodies (MABs) that would be used as vehicles to transport the nontoxic agent to cancer cells. The anti HER-2 MABs have been successful in targeting HER-2 positive breast cancers with high affinity. The proposed concept would utilize a neutral nontoxic boron-10 predicting that anti HER-2 MABs would assure its selective delivery to cancer cells. MABs against HER-2 have been a widely researched strategy in the clinical setting. The most promising antibody is Trastuzumab (Herceptin (registered) ). Targeting HER-2 with the MAB Trastuzumab has been proven to be a successful strategy in inducing tumour regression and improving patient survival. Unfortunately, these tumours become resistant and afflicted women succumb to breast cancer. In the proposed concept, when the tumour region is loaded with boron-10 it is irradiated with neutrons (treatment used for head and neck cancers, melanoma and glioblastoma for over 40 years in Japan and Europe). The irradiation process takes less than an hour producing minimal side effects. This paper summarizes our recent theoretical assessments of radiation binary targeted therapy for HER-2 positive breast cancers on: the effective drug delivery mechanism, the numerical model to evaluate the targeted radiation delivery and the survey study to find the neutron facility in the world that might be capable of producing the radiation effect as needed. A novel method of drug delivery utilizing Trastuzumab is described, followed by the description of a computational Monte Carlo based breast model used to determine radiation dose distributions. The total flux and neutron energy spectra of five currently available

  20. THE URINE PROTEOME FOR RADIATION BIODOSIMETRY: EFFECT OF TOTAL BODY VERSUS LOCAL KIDNEY IRRADIATION

    Science.gov (United States)

    Sharma, Mukut; Halligan, Brian D.; Wakim, Bassam T.; Savin, Virginia J.; Cohen, Eric P.; Moulder, John E.

    2009-01-01

    Victims of nuclear accidents or radiological terrorism are likely to receive varying doses of ionizing radiation inhomogeneously distributed over the body. Early biomarkers may be useful in determining organ-specific doses due to total body irradiation (TBI) or partial body irradiation. We used liquid chromatography and mass spectrometry to compare the effect of TBI and local kidney irradiation (LKI) on the rat urine proteome using a single 10 Gy dose of X-rays. Both TBI and LKI altered the urinary protein profile within 24 hours with noticeable differences in Gene Ontology categories. Some proteins including fetuin-B, tissue kallikrein, beta-glucuronidase, vitamin D-dependent calcium binding protein and chondroitin sulfate proteoglycan NG2 were detected only in the TBI group. Some other proteins including major urinary protein-1, RNA binding protein 19, neuron navigator, Dapper homolog 3, WD repeat and FYVE domain containing protein 3, sorting nexin-8, ankycorbin and aquaporin were detected only in the LKI group. Protease inhibitors and kidney proteins were more abundant (fraction of total scans) in the LKI group. Up/Uc ratio and urinary albumin abundance decreased in both TBI and LKI groups. Several markers of acute kidney injury were not detectable in either irradiated group. Present data indicate that abundance and number of proteins may follow opposite trends. These novel findings demonstrate intriguing differences between TBI and LKI, and suggest that urine proteome may be useful in determining organ-specific changes caused by partial body irradiation. PMID:20065682

  1. The urine proteome for radiation biodosimetry: effect of total body vs. local kidney irradiation.

    Science.gov (United States)

    Sharma, Mukut; Halligan, Brian D; Wakim, Bassam T; Savin, Virginia J; Cohen, Eric P; Moulder, John E

    2010-02-01

    Victims of nuclear accidents or radiological terrorism are likely to receive varying doses of ionizing radiation inhomogeneously distributed over the body. Early biomarkers may be useful in determining organ-specific doses due to total body irradiation (TBI) or partial body irradiation. The authors used liquid chromatography and mass spectrometry to compare the effect of TBI and local kidney irradiation (LKI) on the rat urine proteome using a single 10-Gy dose of x-rays. Both TBI and LKI altered the urinary protein profile within 24 h with noticeable differences in gene ontology categories. Some proteins, including fetuin-B, tissue kallikrein, beta-glucuronidase, vitamin D-dependent calcium binding protein and chondroitin sulfate proteoglycan NG2, were detected only in the TBI group. Some other proteins, including major urinary protein-1, RNA binding protein 19, neuron navigator, Dapper homolog 3, WD repeat and FYVE domain containing protein 3, sorting nexin-8, ankycorbin and aquaporin were detected only in the LKI group. Protease inhibitors and kidney proteins were more abundant (fraction of total scans) in the LKI group. Urine protein (Up) and creatinine (Uc) (Up/Uc) ratios and urinary albumin abundance decreased in both TBI and LKI groups. Several markers of acute kidney injury were not detectable in either irradiated group. Present data indicate that abundance and number of proteins may follow opposite trends. These novel findings demonstrate intriguing differences between TBI and LKI, and suggest that urine proteome may be useful in determining organ-specific changes caused by partial body irradiation.

  2. Protection of radiation induced DNA and membrane damages by total triterpenes isolated from Ganoderma lucidum (Fr.) P. Karst.

    Science.gov (United States)

    Smina, T P; Maurya, D K; Devasagayam, T P A; Janardhanan, K K

    2015-05-25

    The total triterpenes isolated from the fruiting bodies of Ganoderma lucidum was examined for its potential to prevent γ-radiation induced membrane damage in rat liver mitochondria and microsomes. The effects of total triterpenes on γ-radiation-induced DNA strand breaks in pBR 322 plasmid DNA in vitro and human peripheral blood lymphocytes ex vivo were evaluated. The protective effect of total triterpenes against γ-radiation-induced micronuclei formations in mice bone marrow cells in vivo were also evaluated. The results indicated the significant effectiveness of Ganoderma triterpenes in protecting the DNA and membrane damages consequent to the hazardous effects of radiation. The findings suggest the potential use of Ganoderma triterpenes in radio therapy. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Direct detection of darkmatter in radiative seesaw model

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Daniel; Schwetz, Thomas [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Toma, Takashi [Institute for Theoretical Physics, Kanazawa University (Japan)

    2012-07-01

    In the radiative seesaw model proposed by Ma, we assume that the lightest right-handed neutrino is the Dark Matter candidate and almost degenerated with the second lightest right-handed neutrino. Thus, elastic Dark Matter-nucleus scattering is suppressed. Inelastic scattering is induced by a lepton-loop coupled to the photon. Effectively, there are charge-charge, dipole-charge and dipole-dipole interactions. We present the event rate of the model and compare it with existing data. Moreover, monochromatic photons from the decay of the excited Dark Matter state are discussed.

  4. Assembly for the measurement of the most probable energy of directed electron radiation

    International Nuclear Information System (INIS)

    Geske, G.

    1987-01-01

    This invention relates to a setup for the measurement of the most probable energy of directed electron radiation up to 50 MeV. The known energy-range relationship with regard to the absorption of electron radiation in matter is utilized by an absorber with two groups of interconnected radiation detectors embedded in it. The most probable electron beam energy is derived from the quotient of both groups' signals

  5. Study The Validity of The Direct Mathematical Method For Calculation The Total Efficiency Using Point And Disk Sources

    International Nuclear Information System (INIS)

    Hagag, O.M.; Nafee, S.S.; Naeem, M.A.; El Khatib, A.M.

    2011-01-01

    The direct mathematical method has been developed for calculating the total efficiency of many cylindrical gamma detectors, especially HPGe and NaI detector. Different source geometries are considered (point and disk). Further into account is taken of gamma attenuation from detector window or any interfacing absorbing layer. Results are compared with published experimental data to study the validity of the direct mathematical method to calculate total efficiency for any gamma detector size.

  6. NRC TLD Direct Radiation Monitoring Network. Progress report, January-June 1981

    International Nuclear Information System (INIS)

    1982-04-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of 55 NRC-licensed facility sites throughout the country for the first half of 1981. The program objectives, scope, and methodology are given. The TLD system, dosimeter location, data processing scheme, and quality assurance program are outlined

  7. NRC TLD Direct Radiation Monitoring Network. Progress report, October-December 1985. Volume 5, No. 4

    International Nuclear Information System (INIS)

    Jang, J.; Rabatin, K.; Cohen, L.

    1986-05-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1985. It provides the ambient radiation levels measured in the vicinity of 74 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program

  8. NRC TLD [thermoluminescent dosimeter] Direct Radiation Monitoring Network: Progress report, October--December 1988

    International Nuclear Information System (INIS)

    Struckmeyer, R.; NcNamara, N.

    1989-04-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1988. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program. 4 tabs

  9. Time-resolved studies of direct effects of radiation on DNA

    International Nuclear Information System (INIS)

    Fielden, E.M.; O'Neill, P.; Al-Kazwini, A.

    1987-01-01

    The biological changes induced by ionising radiation are a consequence of radiation-induced chemical events taking place at times <1s. These events are strongly influenced by the presence of chemical modifiers. Since DNA is a principle target for radiation-induced cell killing, DNA-free radicals are generated by direct ionisation of DNA moieties (direct effect) and by reaction with hydroxyl radicals formed by radiolysis of the water which is in the vicinity of the DNA (indirect effect). In order to study the 'direct' effects of radiation on DNA the following model approaches are discussed:- 1) Use of the technique of pulse radiolysis to investigate in aqueous solution the interactions of deoxynucleosides with SO/sub 4//sup .-/ whereby one-electron oxidised species of the bases are generated; and 2) time resolved, radiation-induced changes to solid DNA and related macromolecules (e.g. radiation-induced luminescence) in order to obtain an understanding of charge/energy migration as a result of ionisation of DNA. The influence of chemical modifiers and of environment is discussed in terms of the properties of the radiation-induced species produced. Since the properties of base radicals produced by SO/sub 4//sup .-/ are similar to those of the base OH-adducts oxidising properties, potential similarities between the 'direct' and 'indirect' effects of radiation are presented

  10. NRC TLD Direct Radiation Monitoring Network progress report, October--December 1994. Volume 14, No. 4

    Energy Technology Data Exchange (ETDEWEB)

    Struckmeyer, R.

    1995-03-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1994. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program.

  11. NRC TLD Direct Radiation Monitoring Network. Progress report, October--December 1996

    International Nuclear Information System (INIS)

    Struckmeyer, R.

    1997-03-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1996. It provides the ambient radiation levels measured in the vicinity of 74 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program. 3 figs., 4 tabs

  12. Implementation of European Directive on Optical Radiation Safety takes place in May 2010

    NARCIS (Netherlands)

    Wieringa, F.P.

    2009-01-01

    At the latest by May 10th 2010, Directive 2006/25/EC regarding the exposure of workers to risks arising from artificial optical radiation must be implemented by all EU-member states, thus legally adopting ICNIRP limit values for ultraviolet, visible and infrared radiation. For IUVA-members the

  13. Direct weakening of tropical circulations from masked CO2 radiative forcing.

    Science.gov (United States)

    Merlis, Timothy M

    2015-10-27

    Climate models robustly simulate weakened mean circulations of the tropical atmosphere in direct response to increased carbon dioxide (CO2). The direct response to CO2, defined by the response to radiative forcing in the absence of changes in sea surface temperature, affects tropical precipitation and tropical cyclone genesis, and these changes have been tied to the weakening of the mean tropical circulation. The mechanism underlying this direct CO2-forced circulation change has not been elucidated. Here, I demonstrate that this circulation weakening results from spatial structure in CO2's radiative forcing. In regions of ascending circulation, such as the intertropical convergence zone, the CO2 radiative forcing is reduced, or "masked," by deep-convective clouds and high humidity; in subsiding regions, such as the subtropics, the CO2 radiative forcing is larger because the atmosphere is drier and deep-convective clouds are infrequent. The spatial structure of the radiative forcing reduces the need for the atmosphere to transport energy. This, in turn, weakens the mass overturning of the tropical circulation. The previously unidentified mechanism is demonstrated in a hierarchy of atmospheric general circulation model simulations with altered radiative transfer to suppress the cloud masking of the radiative forcing. The mechanism depends on the climatological distribution of clouds and humidity, rather than uncertain changes in these quantities. Masked radiative forcing thereby offers an explanation for the robustness of the direct circulation weakening under increased CO2.

  14. NRC TLD Direct Radiation Monitoring Network progress report, October--December 1994. Volume 14, No. 4

    International Nuclear Information System (INIS)

    Struckmeyer, R.

    1995-03-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1994. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program

  15. NRC TLD [Nuclear Regulatory Commission thermoluminescent dosimeter] direct radiation monitoring network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1990-03-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1989. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program

  16. NRC TLD Direct Radiation Monitoring Network. Progress report, October--December 1996

    Energy Technology Data Exchange (ETDEWEB)

    Struckmeyer, R.

    1997-03-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1996. It provides the ambient radiation levels measured in the vicinity of 74 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program. 3 figs., 4 tabs.

  17. Directional Radiometry and Radiative Transfer: the Convoluted Path From Centuries-old Phenomenology to Physical Optics

    Science.gov (United States)

    Mishchenko, Michael I.

    2014-01-01

    This Essay traces the centuries-long history of the phenomenological disciplines of directional radiometry and radiative transfer in turbid media, discusses their fundamental weaknesses, and outlines the convoluted process of their conversion into legitimate branches of physical optics.

  18. Direct time-domain techniques for transient radiation and scattering

    International Nuclear Information System (INIS)

    Miller, E.K.; Landt, J.A.

    1976-01-01

    A tutorial introduction to transient electromagnetics, focusing on direct time-domain techniques, is presented. Physical, mathematical, numerical, and experimental aspects of time-domain methods, with emphasis on wire objects excited as antennas or scatters are examined. Numerous computed examples illustrate the characteristics of direct time-domain procedures, especially where they may offer advantages over procedures in the more familiar frequency domain. These advantages include greater solution efficiency for many types of problems, the ability to handle nonlinearities, improved physical insight and interpretability, availability of wide-band information from a single calculation, and the possibility of isolating interactions among various parts of an object using time-range gating

  19. Asymmetric active nano-particles for directive near-field radiation

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Thorsen, Rasmus O.

    2016-01-01

    In this work, we demonstrate the potential of cylindrical active coated nano-particles with certain geometrical asymmetries for the creation of directive near-field radiation. The particles are excited by a near-by magnetic line source, and their performance characteristics are reported in terms...... of radiated power, near-field and power flow distributions as well as the far-field directivity....

  20. Aerosol optical properties and direct radiative forcing at Taihu.

    Science.gov (United States)

    Lü, Rui; Yu, Xingna; Jia, Hailing; Xiao, Sihan

    2017-09-01

    Ground-based characteristics (optical, type, size, and radiative properties) of aerosols measured between 2005 and 2012 were investigated over the Taihu rim region, which encompasses the cities of Shanghai, Suzhou, Wuxi, and Changzhou. The aerosol optical depth (AOD) showed a distinct seasonal variation with the highest value in summer and the lowest AOD in winter. There was broadest frequency distribution with a multimodal structure in summer. The Ångström exponent (AE) showed high values during spring; the relative frequency of AE in the range of 0-0.8 was 5-10 times greater than that of other seasons. The samples with high AOD 440 and low AE 440-870 were mainly observed in spring, which is attributed to the relative abundance of coarse particles. The monthly aerosol volume size distributions presented a bimodal structure (fine and coarse modes). The coarse mode was dominant during spring, while the fine mode was predominant in other seasons. The main aerosol type over Taihu during all the seasons was the mixed small-particle category, followed by the urban/industrial category. The minimum single scattering albedo (SSA) occurred in winter, suggesting that atmosphere aerosol had a higher absorption. All monthly averaged asymmetry factors (ASY) had positive values and no distinct seasonal variation. Both high real (Re) and imaginary (Im) parts of the refractive index occurred in winter. The atmospheric warming effect of aerosol was more significant in winter compared with other seasons, with the averaged atmosphere aerosol radiative forcing (ARF) and the corresponding atmospheric heating rate up to +69.46  W·m -2 and 1.95  K·day -1 , respectively. There existed a significant positive correlation between AOD and ARF (absolute value), and the correlation coefficients (r) exceeded 0.86 in each season with maximum r in summer. Along with the increasing of the SSA, the aerosol radiative forcing efficiency (absolute value) showed a decreasing trend at the

  1. Synchrotron Radiation Total Reflection X-ray Fluorescence Spectroscopy for Microcontamination Analysis on Silicon Wafer Surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Takaura, Norikatsu

    1997-10-01

    As dimensions in state-of-the-art CMOS devices shrink to less than 0.1 pm, even low levels of impurities on wafer surfaces can cause device degradation. Conventionally, metal contamination on wafer surfaces is measured using Total Reflection X-Ray Fluorescence Spectroscopy (TXRF). However, commercially available TXRF systems do not have the necessary sensitivity for measuring the lower levels of contamination required to develop new CMOS technologies. In an attempt to improve the sensitivity of TXRF, this research investigates Synchrotron Radiation TXRF (SR TXRF). The advantages of SR TXRF over conventional TXRF are higher incident photon flux, energy tunability, and linear polarization. We made use of these advantages to develop an optimized SR TXRF system at the Stanford Synchrotron Radiation Laboratory (SSRL). The results of measurements show that the Minimum Detection Limits (MDLs) of SR TXRF for 3-d transition metals are typically at a level-of 3x10{sup 8} atoms/cm{sup 2}, which is better than conventional TXRF by about a factor of 20. However, to use our SR TXRF system for practical applications, it was necessary to modify a commercially available Si (Li) detector which generates parasitic fluorescence signals. With the modified detector, we could achieve true MDLs of 3x10{sup 8} atoms/cm{sup 2} for 3-d transition metals. In addition, the analysis of Al on Si wafers is described. Al analysis is difficult because strong Si signals overlap the Al signals. In this work, the Si signals are greatly reduced by tuning the incident beam energy below the Si K edge. The results of our measurements show that the sensitivity for Al is limited by x-ray Raman scattering. Furthermore, we show the results of theoretical modeling of SR TXRF backgrounds consisting of the bremsstrahlung generated by photoelectrons, Compton scattering, and Raman scattering. To model these backgrounds, we extended conventional theoretical models by taking into account several aspects particular

  2. Anisotropic Margin Expansions in 6 Anatomic Directions for Oropharyngeal Image Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Yock, Adam D.; Garden, Adam S.; Court, Laurence E.; Beadle, Beth M.; Zhang, Lifei; Dong, Lei

    2013-01-01

    Purpose: The purpose of this work was to determine the expansions in 6 anatomic directions that produced optimal margins considering nonrigid setup errors and tissue deformation for patients receiving image-guided radiation therapy (IGRT) of the oropharynx. Methods and Materials: For 20 patients who had received IGRT to the head and neck, we deformably registered each patient's daily images acquired with a computed tomography (CT)-on-rails system to his or her planning CT. By use of the resulting vector fields, the positions of volume elements within the clinical target volume (CTV) (target voxels) or within a 1-cm shell surrounding the CTV (normal tissue voxels) on the planning CT were identified on each daily CT. We generated a total of 15,625 margins by dilating the CTV by 1, 2, 3, 4, or 5 mm in the posterior, anterior, lateral, medial, inferior, and superior directions. The optimal margins were those that minimized the relative volume of normal tissue voxels positioned within the margin while satisfying 1 of 4 geometric target coverage criteria and 1 of 3 population criteria. Results: Each pair of geometric target coverage and population criteria resulted in a unique, anisotropic, optimal margin. The optimal margin expansions ranged in magnitude from 1 to 5 mm depending on the anatomic direction of the expansion and on the geometric target coverage and population criteria. Typically, the expansions were largest in the medial direction, were smallest in the lateral direction, and increased with the demand of the criteria. The anisotropic margin resulting from the optimal set of expansions always included less normal tissue than did any isotropic margin that satisfied the same pair of criteria. Conclusions: We demonstrated the potential of anisotropic margins to reduce normal tissue exposure without compromising target coverage in IGRT to the head and neck

  3. Spatial variability of the direct radiative forcing of biomass burning aerosols and the effects of land use change in Amazonia

    Directory of Open Access Journals (Sweden)

    E. T. Sena

    2013-02-01

    −2. Biomass burning aerosols impact the radiative budget for approximately two months per year, whereas the surface albedo impact is observed throughout the year. Because of this difference, the estimated impact in the Amazonian annual radiative budget due to surface albedo-change is approximately 6 times higher than the impact due to aerosol emissions. The influence of atmospheric water vapour content in the radiative budget was also studied using AERONET column water vapour. It was observed that column water vapour is on average smaller by about 0.35 cm (around 10% of the total column water vapour over deforested areas compared to forested areas. Our results indicate that this drying contributes to an increase in the shortwave radiative forcing, which varies from 0.4 W m−2 to 1.2 W m−2 depending on the column water vapour content before deforestation.

    The large radiative forcing values presented in this study point out that deforestation could have strong implications in convection, cloud development and the ratio of direct to diffuse radiation, which impacts carbon uptake by the forest.

  4. Modelled radiative forcing of the direct aerosol effect with multi-observation evaluation

    Directory of Open Access Journals (Sweden)

    G. Myhre

    2009-02-01

    Full Text Available A high-resolution global aerosol model (Oslo CTM2 driven by meteorological data and allowing a comparison with a variety of aerosol observations is used to simulate radiative forcing (RF of the direct aerosol effect. The model simulates all main aerosol components, including several secondary components such as nitrate and secondary organic carbon. The model reproduces the main chemical composition and size features observed during large aerosol campaigns. Although the chemical composition compares best with ground-based measurement over land for modelled sulphate, no systematic differences are found for other compounds. The modelled aerosol optical depth (AOD is compared to remote sensed data from AERONET ground and MODIS and MISR satellite retrievals. To gain confidence in the aerosol modelling, we have tested its ability to reproduce daily variability in the aerosol content, and this is performing well in many regions; however, we also identified some locations where model improvements are needed. The annual mean regional pattern of AOD from the aerosol model is broadly similar to the AERONET and the satellite retrievals (mostly within 10–20%. We notice a significant improvement from MODIS Collection 4 to Collection 5 compared to AERONET data. Satellite derived estimates of aerosol radiative effect over ocean for clear sky conditions differs significantly on regional scales (almost up to a factor two, but also in the global mean. The Oslo CTM2 has an aerosol radiative effect close to the mean of the satellite derived estimates. We derive a radiative forcing (RF of the direct aerosol effect of −0.35 Wm−2 in our base case. Implementation of a simple approach to consider internal black carbon (BC mixture results in a total RF of −0.28 Wm−2. Our results highlight the importance of carbonaceous particles, producing stronger individual RF than considered in the recent IPCC estimate; however, net RF is less different

  5. Directivity of seismic radiation from a series of line charges

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, Thomas J [Lawrence Radiation Laboratory, University of California, Livermore, CA (United States)

    1970-05-15

    A series of two-dimensional calculations describing the stress wave propagation from a row of line explosive sources, detonated sequentially at a supersonic phase velocity on the surface of various layered (half-space) crustal models, was carried out. Spectral ratios of the resulting free-surface velocities at a series of hypothetical seismic stations were used to calculate directivity functions. As in the case considered earlier by Ben-Menahem (where the source moved subsonically), strong enhancement of certain frequencies in the spectrum of the horizontal component of velocity was obtained. Directivity is especially prominent when the explosion-induced signals are generated in a medium in which the longitudinal elastic wave velocity is comparable to the detonation phase velocity and when the seismic signal being analyzed has been refracted from a higher-velocity, underlying layer. (author)

  6. Mixed Total Variation and L1 Regularization Method for Optical Tomography Based on Radiative Transfer Equation

    Directory of Open Access Journals (Sweden)

    Jinping Tang

    2017-01-01

    Full Text Available Optical tomography is an emerging and important molecular imaging modality. The aim of optical tomography is to reconstruct optical properties of human tissues. In this paper, we focus on reconstructing the absorption coefficient based on the radiative transfer equation (RTE. It is an ill-posed parameter identification problem. Regularization methods have been broadly applied to reconstruct the optical coefficients, such as the total variation (TV regularization and the L1 regularization. In order to better reconstruct the piecewise constant and sparse coefficient distributions, TV and L1 norms are combined as the regularization. The forward problem is discretized with the discontinuous Galerkin method on the spatial space and the finite element method on the angular space. The minimization problem is solved by a Jacobian-based Levenberg-Marquardt type method which is equipped with a split Bregman algorithms for the L1 regularization. We use the adjoint method to compute the Jacobian matrix which dramatically improves the computation efficiency. By comparing with the other imaging reconstruction methods based on TV and L1 regularizations, the simulation results show the validity and efficiency of the proposed method.

  7. Radiation exposure to patient's skin during percutaneous coronary intervention for various lesions, including chronic total occlusion

    International Nuclear Information System (INIS)

    Suzuki, Shigeru; Furui, Shigeru; Kohtake, Hiroshi; Yokoyama, Naoyuki; Kozuma, Ken; Yamamoto, Yoshito; Isshiki, Takaaki

    2006-01-01

    Radiation skin injuries have been reported as a result of various procedures, so in the present study the patients' entrance skin dose (ESD) during percutaneous coronary intervention (PCI) was evaluated. ESDs were assessed during 97 procedures (13 for chronic total occlusion (CTO), 14 for multivessel stenoses, 22 for single-vessel multiple stenoses, and 48 for single stenosis). The patients wore jackets that had 48 or 52 radiosensitive indicators placed on the back during the PCI procedures, with 8 other indicators placed on both upper arms. After the procedure, the color of the indicators was analyzed with a color measuring instrument, and the patients' ESDs were calculated from the color difference of the indicators. The average maximum ESDs of the patients were 4.5±2.8 Gy (median: 4.6 Gy) for CTO, 2.3±0.7 Gy (median: 2.4 Gy) for multi-vessel stenoses, 1.8±1.0 Gy (median: 1.5 Gy) for single-vessel multiple stenoses, and 1.4±0.9 Gy (median: 1.2 Gy) for single stenosis. Skin injury can occur during PCI, especially for CTO, so it is important to estimate each patient's ESD and attempt to reduce it. (author)

  8. Multielemental analysis in cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Barbosa, R.F.; Anjos, M.J. dos; Jesus, E.F.O. de; Lopes, R.T.; Moreira, S.

    2008-01-01

    Full text: It is well known that trace elements have important ejects in the life processes. Some of these elements are toxic for the human even at a very low level of intake. It is known that tobacco plant easily absorbs the heavy metals from the soil, especially Cd and Ni, accumulating them in its leaves. Part of these metals are transferred from tobacco to human body where they will be accumulated and damage some organs, mainly kidneys and liver. In this way, cigarettes are responsible for the death of millions of people in the world, about one death every eight seconds. The aim of this work was to determine the elemental concentrations of ten different elements in tobacco of Brazilian cigarettes used Total Reflection X-Ray Fluorescence with Synchrotron Radiation method. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. A qualitative analysis of spectral peaks showed that the samples contained potassium, calcium, titanium, chromium, manganese, iron, copper, rubidium and strontium. Among these elements, calcium, potassium and iron presented the highest concentrations. There was a wide range in the elemental concentrations in the tobacco, due various factors, such as agricultural practices, soil characteristics, climatic conditions and plant varieties. Our results are in good concern with the results reported by the scientific literature

  9. Future directions in radiation protection in nuclear power plants

    International Nuclear Information System (INIS)

    Lewis, L.

    1987-01-01

    Our visions of the future are often very optimistic and hopeful, representing the best imaginings of the human mind. The authors are inclined to think of the future as filled with new and better things. Some people even visualize the future as a science fiction perfection, but, in reality, it will also contain elements of the past and the present, both good and bad. With respect to radiation protection, a guess would tell us that the future holds the implementation of some version of ICRP-26 in one revision or another of the NRC 10 CFR20 regulations. But many of the technical problems of today may likely be ''solved'' by the public, the politicians, the sociologists and the bureaucrats of the future. For example, two such ''solutions'' may possibly appear in such grotesque forms as drastically lowered allowable annual doses or as engineered facilities for the disposal of low-level radioactive waste above ground on seismic stilts. All of these aspects - the good, the bad, the new, the old, and the indifferent - are all touched upon in this vision of the future

  10. Comparative Study on Radiological Impact Due To Direct Exposure to a Radiological Dispersal Device Using A Sealed Radiation Source

    International Nuclear Information System (INIS)

    Margeanu, C.A.

    2011-01-01

    Nowadays, one of the most serious terrorist threats implies radiological dispersal devices (RDDs), the so-called dirty bombs, that combine a conventional explosive surrounded by an inflammatory material (like thermit) with radioactive material. The paper objective is to evaluate the radiological impact due to direct exposure to a RDD using a sealed radiation source (used for medical and industrial applications) as radioactive material. The simulations were performed for 60Co, 137Cs and 192Ir radiation sources. In order to model the contamination potential level and radiation exposure due to radioactive material spreading from RDD, Lawrence Livermore National Laboratory's HOTSPOT 2.07 computer code was used. The worst case scenario has been considered, calculations being performed for two radioactive material dispersion models, namely General radioactive Plume and General Explosion. Following parameters evolution with distance from the radiation source was investigated: total effective dose equivalent, time-integrated air concentration, ground surface deposition and ground shine dose rates. Comparisons between considered radiation sources and radioactive material dispersion models have been performed. The most drastic effects on population and the environment characterize 60Co sealed radiation source use in RDD.

  11. Leaf color is fine-tuned on the solar spectra to avoid strand direct solar radiation.

    Science.gov (United States)

    Kume, Atsushi; Akitsu, Tomoko; Nasahara, Kenlo Nishida

    2016-07-01

    The spectral distributions of light absorption rates by intact leaves are notably different from the incident solar radiation spectra, for reasons that remain elusive. Incident global radiation comprises two main components; direct radiation from the direction of the sun, and diffuse radiation, which is sunlight scattered by molecules, aerosols and clouds. Both irradiance and photon flux density spectra differ between direct and diffuse radiation in their magnitude and profile. However, most research has assumed that the spectra of photosynthetically active radiation (PAR) can be averaged, without considering the radiation classes. We used paired spectroradiometers to sample direct and diffuse solar radiation, and obtained relationships between the PAR spectra and the absorption spectra of photosynthetic pigments and organs. As monomers in solvent, the spectral absorbance of Chl a decreased with the increased spectral irradiance (W m(-2) nm(-1)) of global PAR at noon (R(2) = 0.76), and was suitable to avoid strong spectral irradiance (λmax = 480 nm) rather than absorb photon flux density (μmol m(-2) s(-1) nm(-1)) efficiently. The spectral absorption of photosystems and the intact thallus and leaves decreased linearly with the increased spectral irradiance of direct PAR at noon (I dir-max), where the wavelength was within the 450-650 nm range (R(2) = 0.81). The higher-order structure of photosystems systematically avoided the strong spectral irradiance of I dir-max. However, when whole leaves were considered, leaf anatomical structure and light scattering in leaf tissues made the leaves grey bodies for PAR and enabled high PAR use efficiency. Terrestrial green plants are fine-tuned to spectral dynamics of incident solar radiation and PAR absorption is increased in various structural hierarchies.

  12. Ganoderma lucidum total triterpenes prevent γ-radiation induced oxidative stress in Swiss albino mice in vivo.

    Science.gov (United States)

    Smina, T P; Joseph, Jini; Janardhanan, K K

    2016-11-01

    The in vivo radio-protective effect of total triterpenes isolated from Ganoderma lucidum (Fr.) P. Karst was evaluated using Swiss albino mice, by pre-treatment with total triterpenes for 14 days, followed by a whole body exposure to γ-radiation. The activities of the antioxidant enzymes superoxide dismutase (SOD), catalase (CAT), and glutathione peroxidase (GPx), and the level of reduced glutathione (GSH) were analysed in liver and brain homogenates. The extent of lipid and protein peroxidation was also estimated in liver and brain homogenates after irradiation. Protection of radiation-induced DNA strand breaks in peripheral blood lymphocytes and bone marrow cells was assessed using the comet assay. Total triterpenes were highly effective in reducing the levels of lipid peroxidation and protein oxidation to near normal values in both liver and brain tissues. Total triterpenes, when administered in vivo, were also found to be successful in restoring the antioxidant enzyme activities and GSH level in liver and brain of irradiated mice. Administration of total triterpenes, prior to radiation exposure, significantly decreased the DNA strand breaks. The results of the present study thus revealed the potential therapeutic use of Ganoderma total triterpenes as an adjuvant in radiation therapy.

  13. Computed tomography for preoperative planning in minimal-invasive total hip arthroplasty: Radiation exposure and cost analysis

    Energy Technology Data Exchange (ETDEWEB)

    Huppertz, Alexander, E-mail: Alexander.Huppertz@charite.de [Imaging Science Institute Charite Berlin, Robert-Koch-Platz 7, D-10115 Berlin (Germany); Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Radmer, Sebastian, E-mail: s.radmer@immanuel.de [Department of Orthopedic Surgery and Rheumatology, Immanuel-Krankenhaus, Koenigstr. 63, D-14109, Berlin (Germany); Asbach, Patrick, E-mail: Patrick.Asbach@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Juran, Ralf, E-mail: ralf.juran@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Schwenke, Carsten, E-mail: carsten.schwenke@scossis.de [Biostatistician, Scossis Statistical Consulting, Zeltinger Str. 58G, D-13465 Berlin (Germany); Diederichs, Gerd, E-mail: gerd.diederichs@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Hamm, Bernd, E-mail: Bernd.Hamm@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Sparmann, Martin, E-mail: m.sparmann@immanuel.de [Department of Orthopedic Surgery and Rheumatology, Immanuel-Krankenhaus, Koenigstr. 63, D-14109, Berlin (Germany)

    2011-06-15

    Computed tomography (CT) was used for preoperative planning of minimal-invasive total hip arthroplasty (THA). 92 patients (50 males, 42 females, mean age 59.5 years) with a mean body-mass-index (BMI) of 26.5 kg/m{sup 2} underwent 64-slice CT to depict the pelvis, the knee and the ankle in three independent acquisitions using combined x-, y-, and z-axis tube current modulation. Arthroplasty planning was performed using 3D-Hip Plan (Symbios, Switzerland) and patient radiation dose exposure was determined. The effects of BMI, gender, and contralateral THA on the effective dose were evaluated by an analysis-of-variance. A process-cost-analysis from the hospital perspective was done. All CT examinations were of sufficient image quality for 3D-THA planning. A mean effective dose of 4.0 mSv (SD 0.9 mSv) modeled by the BMI (p < 0.0001) was calculated. The presence of a contralateral THA (9/92 patients; p = 0.15) and the difference between males and females were not significant (p = 0.08). Personnel involved were the radiologist (4 min), the surgeon (16 min), the radiographer (12 min), and administrative personnel (4 min). A CT operation time of 11 min and direct per-patient costs of 52.80 Euro were recorded. Preoperative CT for THA was associated with a slight and justifiable increase of radiation exposure in comparison to conventional radiographs and low per-patient costs.

  14. Spectral and directional radiation characteristics of thin-film coated isothermal semitransparent plates

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, R P; Viskanta, R

    1975-01-01

    An analysis is presented for predicting the effective spectral directional radiation characteristics of an isothermal, semitransparent sheet surrounded on both sides by massive dielectrics. The sheet can be coated with an optically thin film and used as selective cover plates for solar collectors. Directional and polarization effects and the spectral transmittance and reflectance are considered. Sample results for candidate materials are presented.

  15. A computerized total-radiation management system for Shikoku Electric Power's Ikata nuclear-power plant

    International Nuclear Information System (INIS)

    Hirao, Toshiyuki; Sakakihara, Tetsuro; Tanabe, Shozo; Kano, Mamoru; Hoshi, Jun-ichi.

    1985-01-01

    This system allows on-line, real-time radiation management at nuclear-power plants. It increases management precision, decreases management workloads, and saves labor in operations that previously required specialized technicians to expend great amounts of time and effort on radiation management at facilities and their environments, environmental radiation evaluation, and control of radioactive waste. The article outlines the already installed system. (author)

  16. Study of the fluctuations of the partial and total radiative widths by neutron capture resonance method; Etude des fluctuations des largeurs radiatives partielles et totales par la capture des neutrons de resonance

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, V D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-06-01

    Radiative capture experiments by neutron time-of-flight methods have been made for following studies: distribution of partial radiative widths, effects of correlation between different radiative transitions, fluctuations of total radiative widths {gamma}{sub {gamma}} from resonance to resonance, variation of {gamma}{sub {gamma}} with number of mass and the search for the existence of potential capture. Also, some other experiments with the use of neutron capture gamma-rays spectra have been investigated. (author) [French] Par la capture des neutrons de resonance dont les energies sont selectionnees a l'aide de la technique du temps de vol, differents types d'experiences ont ete realisees concernant les etudes des distributions des largeurs radiatives partielles, des effets de correlation entre differentes voies de desexcitation, de la fluctuation des largeurs radiatives totales {gamma}{sub {gamma}} de resonance a resonance, de la variation de la quantite {gamma}{sub {gamma}} en fonction du nombre de masse et de la mise en evidence de l'existence du processus de capture potentielle. Quelques autres applications de l'emploi du spectre de rayons gamma ont egalement ete presentees. (auteur)

  17. Study of the fluctuations of the partial and total radiative widths by neutron capture resonance method; Etude des fluctuations des largeurs radiatives partielles et totales par la capture des neutrons de resonance

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, V.D. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-06-01

    Radiative capture experiments by neutron time-of-flight methods have been made for following studies: distribution of partial radiative widths, effects of correlation between different radiative transitions, fluctuations of total radiative widths {gamma}{sub {gamma}} from resonance to resonance, variation of {gamma}{sub {gamma}} with number of mass and the search for the existence of potential capture. Also, some other experiments with the use of neutron capture gamma-rays spectra have been investigated. (author) [French] Par la capture des neutrons de resonance dont les energies sont selectionnees a l'aide de la technique du temps de vol, differents types d'experiences ont ete realisees concernant les etudes des distributions des largeurs radiatives partielles, des effets de correlation entre differentes voies de desexcitation, de la fluctuation des largeurs radiatives totales {gamma}{sub {gamma}} de resonance a resonance, de la variation de la quantite {gamma}{sub {gamma}} en fonction du nombre de masse et de la mise en evidence de l'existence du processus de capture potentielle. Quelques autres applications de l'emploi du spectre de rayons gamma ont egalement ete presentees. (auteur)

  18. Chondrosarcoma arising within a radiation-induced osteochondroma several years following childhood total body irradiation: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Shuji [Kurume University Hospital, Department of Radiology, Fukuoka (Japan); Shen, Robert K. [Mayo Clinic, Department of Surgery, Rochester, MN (United States); Laack, Nadia N. [Mayo Clinic, Department of Radiation Oncology, Rochester, MN (United States); Inwards, Carrie Y. [Mayo Clinic, Department of Pathology, Rochester, MN (United States); Wenger, Doris E.; Amrami, Kimberly K. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2013-08-15

    Malignant degeneration arising in radiation-induced osteochondromas is extremely rare. We report a case of a 34-year-old man with a chondrosarcoma arising from an osteochondroma of the left posterior eighth rib that developed following total body irradiation received as part of the conditioning regimen prior to bone marrow transplantation at age 8. To our knowledge, this is only the fourth reported case of a chondrosarcoma arising within a radiation-induced osteochondroma and the first case occurring following childhood total body irradiation. (orig.)

  19. Chondrosarcoma arising within a radiation-induced osteochondroma several years following childhood total body irradiation: Case report

    International Nuclear Information System (INIS)

    Nagata, Shuji; Shen, Robert K.; Laack, Nadia N.; Inwards, Carrie Y.; Wenger, Doris E.; Amrami, Kimberly K.

    2013-01-01

    Malignant degeneration arising in radiation-induced osteochondromas is extremely rare. We report a case of a 34-year-old man with a chondrosarcoma arising from an osteochondroma of the left posterior eighth rib that developed following total body irradiation received as part of the conditioning regimen prior to bone marrow transplantation at age 8. To our knowledge, this is only the fourth reported case of a chondrosarcoma arising within a radiation-induced osteochondroma and the first case occurring following childhood total body irradiation. (orig.)

  20. SOGRO (Superconducting Omni-directional Gravitational Radiation Observatory)

    Science.gov (United States)

    Paik, Ho Jung

    2018-01-01

    Detection of gravitational waves (GWs) from merging binary black holes (BHs) by Advanced LIGO has ushered in the new era of GW astronomy. Many conceivable sources such as intermediate-mass BH binaries and white dwarf binaries, as well as stellar-mass BH inspirals, would emit GWs below 10 Hz. It is highly desirable to open a new window for GW astronomy in the infrasound frequency band. A low-frequency tensor detector could be constructed by combining six magnetically levitated superconducting test masses. Such a detector would be equally sensitive to GWs coming from anywhere in the sky, and would be capable of resolving the source direction and wave polarization. I will present the design concept of a new terrestrial GW detector, named SOGRO, which could reach a strain sensitivity of 10-19-10-21 Hz-1/2 at 0.1-10 Hz. Seismic and Newtonian gravity noises are serious obstacles in constructing terrestrial GW detectors at frequencies below 10 Hz. I will explain how these noises are rejected in SOGRO. I will also report the progress made in designing the platform and modelling its thermal noise.

  1. Model for radiation damage in cells by direct effect and by indirect effect: a radiation chemistry approach

    International Nuclear Information System (INIS)

    Michaels, H.B.; Hunt, J.W.

    1978-01-01

    A model is presented to describe the contributions of direct and indirect effects to the radiation damage of cells. The model is derived using principles of radiation chemistry and of pulse radiolysis in particular. From data available in the literature, parameters for cellular composition and values of rate constants for indirect action have been used in preliminary applications of the model. The results obtained in calculations of the protective effect of .OH and .H scavengers are consistent with experimental data. Possible modifications and improvements to the model are suggested, along with proposed future applications of the model in radiobiological studies

  2. Results of a 5-Week Schedule of Modern Total Skin Electron Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Morris, Stephen Lloyd, E-mail: stephen.morris@gstt.nhs.uk [St Johns Institute of Dermatology, Guys and St Thomas Hospital, London (United Kingdom); McGovern, Mark; Bayne, Sally; Wain, Mary; Child, Fiona; Whittaker, Sean [St Johns Institute of Dermatology, Guys and St Thomas Hospital, London (United Kingdom)

    2013-08-01

    Purpose: To report the outcomes of a 5-week schedule of total skin electron beam radiation therapy (TSEB) for mycosis fungoides (MF). Methods: Over 5 years, 41 patients with confirmed MF were treated with a modern TSEB technique delivering 30 Gy in 20 fractions over 5 weeks to the whole skin surface. Data were collected prospectively and entered into the skin tumor unit research database. Skin modified skin weighted assessment tool score data were collected to determine response, duration of response, survival, and toxicity. The outcomes were analyzed according to the patient's stage before TSEB, prognostic factors, and adjuvant treatments. Results: Seventeen patients were stage 1B, 19 were stage IIB, 3 were stage III, and 2 were stage IV. The overall response rate was 95%, with a complete response rate of 51%. Seventy-six percent of patients had relapsed at median follow-up of 18 months. The median time to relapse was 12 months, to systemic therapy was 15 months, and to modified skin weighted assessment tool progression above baseline was 44 months. The complete response rate was 59% in stage IB and 47% in stage IIB patients. The median time to skin relapse was longer in stage IB compared with stage IIB, 18 months versus 9 months. The median time to systemic therapy was longer in stage IB compared with stage IIB, >56 months versus 8 months. The median overall survival was 35 months: >56 months for stage IB, 25 months for stage IIB, 46 months for stage III, and 23.5 months for stage IV. Fifteen patients received adjuvant psoralen + ultraviolet A treatment with no difference seen in the time to relapse. Conclusions: This 5-week schedule of TSEB for MF has a high response rate with comparable duration of response to other regimens. Future studies are needed to find adjuvant and combination treatments to improve the duration of response.

  3. Effect of radiation therapy on lipid peroxidation and total antioxidant capacity of blood and saliva in oral cancer patients

    International Nuclear Information System (INIS)

    Lobo, Aswin D.A.

    2012-01-01

    Radiation therapy is reported to induce oxidative stress in oral cancer patients. Saliva as a diagnostic tool has received increasing attention in recent years. Saliva analysis is proposed to be a noninvasive, sensitive tool for the evaluation of biological effects of radiation therapy in oral cancer. We aimed to assess the effect of radiation therapy on malondialdehyde, the marker of lipid peroxidation, and total antioxidant capacity in blood and saliva of oral cancer patients. We also aimed to assess the correlation between blood and saliva with respect to malonaldehyde (MDA) level and total antioxidant capacity (TAC). Thirty, clinically diagnosed oral cancer patients visiting the Oncology Department were the subjects. Thirty age- and sex-matched normal, healthy controls were included. Blood and saliva samples were collected from controls, and from oral cancer patients before and after radiation therapy. The samples were analyzed for MDA and TAC by standard spectrophotometric methods. Oral cancer patients showed significantly higher MDA level and lower TAC in blood and saliva when compared to controls. One week after radiation therapy, there was significant increase in MDA and decrease in TAC in oral cancer patients. After the completion of radiation therapy of six weeks, MDA level decreased and TAC increased, restoring the values near-to-controls. The pattern of change in MDA and TAC was similar between blood and saliva. There was significant correlation between blood and saliva with respect to MDA and TAC in oral cancer patients. Oral cancer patients showed increased oxidative stress and impaired antioxidant capacity. After radiation therapy of one week, oxidative stress increased further, and after six weeks of radiation therapy there was amelioration of antioxidant status. Saliva could be a sensitive and convenient laboratory tool for diagnosis of oral cancer and evaluation of biological effects of radiation therapy. (author)

  4. Workshop Euratom Directive 97/43. New trends in radiation protection in clinical practice, in research and in regulation

    International Nuclear Information System (INIS)

    Mazzei, F.

    1999-01-01

    The Euratom Directive 97/43 on health protection of individuals against the dangers of ionizing radiation in relation to medical exposure is presented. In particular the following topics are focused, with a multidisciplinary approach, on: diagnostic reference levels in radiodiagnostics and nuclear medicine; radiation protection in paediatrics, in interventional radiology and in computer tomography; radiation protection radiotherapy, radiation protection in medical research; radiation protection in prenatal and neonatal exposure; radiation protection in medical-legal exposures [it

  5. A new algorithm to determine the total radiated power at ASDEX upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Gloeggler, Stephan; Bernert, Matthias; Eich, Thomas [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Collaboration: The ASDEX Upgrade Team

    2016-07-01

    Radiation is an essential part of the power balance in a fusion plasma. In future fusion devices about 90% of the power will have to be dissipated, mainly by radiation. For the development of an appropriate operational scenario, information about the absolute level of plasma radiation (P{sub rad,tot}) is crucial. Bolometers are used to measure the radiated power, however, an algorithm is required to derive the absolute power out of many line-integrated measurements. The currently used algorithm (BPD) was developed for the main chamber radiation. It underestimates the divertor radiation as its basic assumptions are not satisfied in this region. Therefore, a new P{sub rad,tot} algorithm is presented. It applies an Abel inversion on the main chamber and uses empirically based assumptions for poloidal asymmetries and the divertor radiation. To benchmark the new algorithm, synthetic emissivity profiles are used. On average, the new Abel inversion based algorithm deviates by only 10% from the nominal synthetic value while BPD is about 25% too low. With both codes time traces of ASDEX Upgrade discharges are calculated. The analysis of these time traces shows that the underestimation of the divertor radiation can have significant consequences on the accuracy of BPD while the new algorithm is shown to be stable.

  6. Models for Total-Dose Radiation Effects in Non-Volatile Memory

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Philip Montgomery; Wix, Steven D.

    2017-04-01

    The objective of this work is to develop models to predict radiation effects in non- volatile memory: flash memory and ferroelectric RAM. In flash memory experiments have found that the internal high-voltage generators (charge pumps) are the most sensitive to radiation damage. Models are presented for radiation effects in charge pumps that demonstrate the experimental results. Floating gate models are developed for the memory cell in two types of flash memory devices by Intel and Samsung. These models utilize Fowler-Nordheim tunneling and hot electron injection to charge and erase the floating gate. Erase times are calculated from the models and compared with experimental results for different radiation doses. FRAM is less sensitive to radiation than flash memory, but measurements show that above 100 Krad FRAM suffers from a large increase in leakage current. A model for this effect is developed which compares closely with the measurements.

  7. Direct and correlated responses to selection for total weight of lamb ...

    African Journals Online (AJOL)

    The estimated selection responses indicate that direct selection for TWW would be the most suitable selection criterion for improving reproductive performance in flocks with a high reproduction rate where an increase in the number of lambs would be undesirable. (South African Journal of Animal Science, 2001, 31(2): ...

  8. A study of the direct effects of ionising and far ultraviolet radiation on nucleic acids

    International Nuclear Information System (INIS)

    Shaw, A.A.

    1987-03-01

    This thesis reports the results of a study of the direct effects of gamma and far UV radiation on nucleic acid model systems. For the gamma study, frozen aqueous solutions of 2'-deoxyribonucleosides were chosen as the model systems which best mimic possible radiation chemical events via the direct effects occuring in DNA in vivo. In Chapter I, we report and discuss the results of the study of the direct effects of gamma radiation on thymidine including the isolation and identification of the chemical modifications induced, and describe experiments designed to probe the mechanisms involved in their formation. In Chapters II and III, we extend the study to other 2'-deoxyribo-nucleosides, 2'-deoxycytidine and 2'-deoxyadenosine. Chapter IV presents the results of the study of the direct effects of far UV light on thymidine, a project designed to complement the gamma study and hopefully to bring additional insight into the mechanisms of formation of those products common to both radiation energies. In particular, the mechanisms of the formation of the spore photoproduct, a lesion known to be formed in DNA in vivo, have been elucidated. The study of the direct effects of gamma radiation on thymidine and 2'-deoxycytidine revealed the formation of several new products. Chapter V reports an analysis of the configurational and conformational properties of these molecules. (author)

  9. [Radiometers performance attenuation and data correction in long-term observation of total radiation and photosynthetically active radiation in typical forest ecosystems in China].

    Science.gov (United States)

    Zhu, Zhi-Lin; Sun, Xiao-Min; Yu, Gui-Rui; Wen, Xue-Fa; Zhang, Yi-Ping; Han, Shi-Jie; Yan, Jun-Hua; Wang, Hui-Min

    2011-11-01

    Based on the total radiation and photosynthetically active radiation (PAR) observations with net radiometer (CNR1) and quantum sensor (Li-190SB) in 4 ChinaFLUX forest sites (Changbaishan, Qianyanzhou, Dinghushan, and Xishuangbanna) in 2003-2008, this paper analyzed the uncertainties and the radiometers performance changes in long-term and continuous field observation. The results showed that the 98% accuracy of the total radiation measured with CNR1 (Q(cNR1)) could satisfy the technical criterion for the sites except Xishuangbanna where the Q(CNR1) was averagely about 7% lower than Q(CM11), the radiation measured with high accuracy pyranometer CM11. For most sites, though the temperature had definite effects on the performance of CNR1, the effects were still within the allowable range of the accuracy of the instrument. Besides temperature, the seasonal fog often occurred in tropical rain forests in Xishuangbanna also had effects on the performance of CNR1. Based on the long-term variations of PAR, especially its ratio to total radiation in the 4 sites, it was found that quantum sensor (Li-190SB) had obvious performance attenuation, with the mean annual attenuation rate being about 4%. To correct the observation error caused by Li-190SB, an attempt was made to give a post-correction of the PAR observations, which could basically eliminate the quantum sensor's performance attenuation due to long-term field measurement.

  10. Directional radiometry and radiative transfer: The convoluted path from centuries-old phenomenology to physical optics

    International Nuclear Information System (INIS)

    Mishchenko, Michael I.

    2014-01-01

    This Essay traces the centuries-long history of the phenomenological disciplines of directional radiometry and radiative transfer in turbid media, discusses their fundamental weaknesses, and outlines the convoluted process of their conversion into legitimate branches of physical optics. - Highlights: • History of phenomenological radiometry and radiative transfer is described. • Fundamental weaknesses of these disciplines are discussed. • The process of their conversion into legitimate branches of physical optics is summarized

  11. Synaptic vesicle exocytosis in hippocampal synaptosomes correlates directly with total mitochondrial volume

    Science.gov (United States)

    Ivannikov, Maxim V.; Sugimori, Mutsuyuki; Llinás, Rodolfo R.

    2012-01-01

    Synaptic plasticity in many regions of the central nervous system leads to the continuous adjustment of synaptic strength, which is essential for learning and memory. In this study, we show by visualizing synaptic vesicle release in mouse hippocampal synaptosomes that presynaptic mitochondria and specifically, their capacities for ATP production are essential determinants of synaptic vesicle exocytosis and its magnitude. Total internal reflection microscopy of FM1-43 loaded hippocampal synaptosomes showed that inhibition of mitochondrial oxidative phosphorylation reduces evoked synaptic release. This reduction was accompanied by a substantial drop in synaptosomal ATP levels. However, cytosolic calcium influx was not affected. Structural characterization of stimulated hippocampal synaptosomes revealed that higher total presynaptic mitochondrial volumes were consistently associated with higher levels of exocytosis. Thus, synaptic vesicle release is linked to the presynaptic ability to regenerate ATP, which itself is a utility of mitochondrial density and activity. PMID:22772899

  12. Radiation therapy for angiosarcoma of the scalp: treatment outcomes of total scalp irradiation with X-rays and electrons.

    Science.gov (United States)

    Hata, Masaharu; Wada, Hidefumi; Ogino, Ichiro; Omura, Motoko; Koike, Izumi; Tayama, Yoshibumi; Odagiri, Kazumasa; Kasuya, Takeo; Inoue, Tomio

    2014-10-01

    Wide surgical excision is the standard treatment for angiosarcoma of the scalp, but many patients are inoperable. Therefore, we investigated the outcome of radiation therapy for angiosarcoma of the scalp. Seventeen patients with angiosarcoma of the scalp underwent radiation therapy with total scalp irradiation. Four patients had cervical lymph node metastases, but none had distant metastases. A median initial dose of 50 Gy in 25 fractions was delivered to the entire scalp. Subsequently, local radiation boost to the tumor sites achieved a median total dose of 70 Gy in 35 fractions. Fourteen of the 17 patients developed recurrences during the median follow-up period of 14 months after radiation therapy; 7 had recurrences in the scalp, including primary tumor progression in 2 patients and new disease in 5, and 12 patients developed distant metastases. The primary progression-free, scalp relapse-free, and distant metastasis-free rates were 86, 67, and 38 % at 1 year and 86, 38, and 16 % at 3 years, respectively. Thirteen patients died; the overall and cause-specific survival rates were both 73 % at 1 year and 23 and 44 % at 3 years, respectively. The median survival time was 16 months. There were no therapy-related toxicities ≥ grade 3. Total scalp irradiation is safe and effective for local tumor control, but a dose of ≤ 50 Gy in conventional fractions may be insufficient to eradicate microscopic tumors. For gross tumors, a total dose of 70 Gy, and > 70 Gy for tumors with deep invasion, is recommended.

  13. Contribution of endogenous and exogenous damage to the total radiation-induced damage in the bacterial spore

    International Nuclear Information System (INIS)

    Jacobs, G.P.; Samuni, A.; Czapski, G.

    1980-01-01

    Radical scavengers such as polyethylene glycol 4000 and bovine albumin have been used to define the contribution of exogenous and endogenous damage to the total radiation-induced damage in aqueous buffered suspensions of Bacillus pumilus spores. The results indicate that this damage in the bacterial spore is predominantly endogenous

  14. Direct and indirect effects of ionizing radiation on grazer-phytoplankton interactions.

    Science.gov (United States)

    Nascimento, Francisco J A; Bradshaw, Clare

    2016-05-01

    Risk assessment of exposure to radionuclides and radiation does not usually take into account the role of species interactions. We investigated how the transfer of carbon between a primary producer, Raphidocelis subcapitata, and a consumer, Daphnia magna, was affected by acute exposure to gamma radiation. In addition to unexposed controls, different treatments were used where: a) only D. magna (Z treatment); b) only R. subcapitata (P treatment) and c) both D. magna and R. subcapitata (ZP treatment) were exposed to one of three acute doses of gamma radiation (5, 50 and 100 Gy). We then compared differences among treatments for three endpoints: incorporation of carbon by D. magna, D. magna growth and R. subcapitata densities. Carbon incorporation was affected by which combination of species was irradiated and by the radiation dose. Densities of R. subcapitata at the end of the experiment were also affected by which species had been exposed to radiation. Carbon incorporation by D. magna was significantly lower in the Z treatment, indicating reduced grazing, an effect stronger with higher radiation doses, possibly due to direct effects of gamma radiation. Top-down indirect effects of this reduced grazing were also seen as R. subcapitata densities increased in the Z treatment due to decreased herbivory. The opposite pattern was observed in the P treatment where only R. subcapitata was exposed to gamma radiation, while the ZP treatment showed intermediate results for both endpoints. In the P treatments, carbon incorporation by D. magna was significantly higher than in the other treatments, suggesting a higher grazing pressure. This, together with direct effects of gamma radiation on R. subcapitata, probably significantly decreased phytoplankton densities in the P treatment. Our results highlight the importance of taking into account the role of species interactions when assessing the effects of exposure to gamma radiation in aquatic ecosystems. Copyright © 2016 The

  15. A Generalized Radiation Model for Human Mobility: Spatial Scale, Searching Direction and Trip Constraint.

    Directory of Open Access Journals (Sweden)

    Chaogui Kang

    Full Text Available We generalized the recently introduced "radiation model", as an analog to the generalization of the classic "gravity model", to consolidate its nature of universality for modeling diverse mobility systems. By imposing the appropriate scaling exponent λ, normalization factor κ and system constraints including searching direction and trip OD constraint, the generalized radiation model accurately captures real human movements in various scenarios and spatial scales, including two different countries and four different cities. Our analytical results also indicated that the generalized radiation model outperformed alternative mobility models in various empirical analyses.

  16. Implementation of ICRP-60, BBS-115 and the patient directives in radiation safety regulations of TAEK

    International Nuclear Information System (INIS)

    Okyar, H.B.; Vural, M.

    2001-01-01

    The use of radiation sources offers a wide range of benefits throughout the world in medicine, research and industry. Precautions are, however, necessary in order to limit the exposure of persons to the radiation that is emitted. The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) were published as IAEA Safety Series No 115 in 1996. This publication marks the culmination of efforts that have continued over the past decades towards harmonization of radiation protection and safety standards internationally. The purpose of the Standards is to establish basic requirements for the protection against the risks associated with exposure to ionizing radiation and for the safety of radiation sources that may deliver such exposure. The Standards are based primarily on the recommendations of the ICRP which is a non-governmental scientific organization to establish basic principles and recommendations for radiation protection; the most recent recommendations of the ICRP were issued in 1991. In 1997, the Council of the European Union published a new directive laying down the general principles of the radiation protection of individuals undergoing exposures to ionizing radiations related to medical exposures (Directive 97/43 Euratom). Directive 97/43 Euratom is a supplement to Directive 96/29 Euratom on the basic safety standards for the protection of the health of workers and the general public against the dangers arising from ionizing radiations. The European Directives 96/29-97/43 Euratom and BSS-115 constitute a complete and coherent set of regulatory measures on radiation protection. In Turkey, the infrastructure exists to account for ionizing radiation sources by, for example, a system of licensing, legislative requirements on the user to keep appropriate records and perhaps to report to the TAEK on a periodic basis or, in the case of imported items (including re-export procedures) and customs

  17. Direct and indirect effects of ionizing radiation on grazer–phytoplankton interactions

    International Nuclear Information System (INIS)

    Nascimento, Francisco J.A.; Bradshaw, Clare

    2016-01-01

    Risk assessment of exposure to radionuclides and radiation does not usually take into account the role of species interactions. We investigated how the transfer of carbon between a primary producer, Raphidocelis subcapitata, and a consumer, Daphnia magna, was affected by acute exposure to gamma radiation. In addition to unexposed controls, different treatments were used where: a) only D. magna (Z treatment); b) only R. subcapitata (P treatment) and c) both D. magna and R. subcapitata (ZP treatment) were exposed to one of three acute doses of gamma radiation (5, 50 and 100 Gy). We then compared differences among treatments for three endpoints: incorporation of carbon by D. magna, D. magna growth and R. subcapitata densities. Carbon incorporation was affected by which combination of species was irradiated and by the radiation dose. Densities of R. subcapitata at the end of the experiment were also affected by which species had been exposed to radiation. Carbon incorporation by D. magna was significantly lower in the Z treatment, indicating reduced grazing, an effect stronger with higher radiation doses, possibly due to direct effects of gamma radiation. Top-down indirect effects of this reduced grazing were also seen as R. subcapitata densities increased in the Z treatment due to decreased herbivory. The opposite pattern was observed in the P treatment where only R. subcapitata was exposed to gamma radiation, while the ZP treatment showed intermediate results for both endpoints. In the P treatments, carbon incorporation by D. magna was significantly higher than in the other treatments, suggesting a higher grazing pressure. This, together with direct effects of gamma radiation on R. subcapitata, probably significantly decreased phytoplankton densities in the P treatment. Our results highlight the importance of taking into account the role of species interactions when assessing the effects of exposure to gamma radiation in aquatic ecosystems. - Highlights: • Direct

  18. Piezoelectric Materials Under Natural and Man-Made Radiation: The Potential for Direct Radiation Detection

    Science.gov (United States)

    Wart, Megan; Simpson, Evan; Flaska, Marek

    2018-01-01

    Radiation detection systems used for monitoring long term waste storage need to be compact, rugged, and have low or no power requirements. By using piezoelectric materials it may be possible to create a reliable self-powered radiation detection system. To determine the feasibility of this approach, the electrical signal response of the piezoelectric materials to radiation must be characterized. To do so, an experimental geometry has been designed and a neutron source has been chosen as described in this paper, which will be used to irradiate a uranium foil for producing fission fragments. These future experiments will be aimed at finding the threshold of exposure of lead zirconate titanate (PZT) plates needed to produce and electrical signal. Based on the proposed experimental geometry the thermal neutron beam-line at the Breazeale Reactor at The Pennsylvania State University will be used as the neutron source. The uranium foil and neutron source will be able to supply a maximum flux of 1.5e5 fission fragments/second*cm2 to each of the PZT plates.

  19. Piezoelectric Materials Under Natural and Man-Made Radiation: The Potential for Direct Radiation Detection

    Directory of Open Access Journals (Sweden)

    Wart Megan

    2018-01-01

    Full Text Available Radiation detection systems used for monitoring long term waste storage need to be compact, rugged, and have low or no power requirements. By using piezoelectric materials it may be possible to create a reliable self-powered radiation detection system. To determine the feasibility of this approach, the electrical signal response of the piezoelectric materials to radiation must be characterized. To do so, an experimental geometry has been designed and a neutron source has been chosen as described in this paper, which will be used to irradiate a uranium foil for producing fission fragments. These future experiments will be aimed at finding the threshold of exposure of lead zirconate titanate (PZT plates needed to produce and electrical signal. Based on the proposed experimental geometry the thermal neutron beam-line at the Breazeale Reactor at The Pennsylvania State University will be used as the neutron source. The uranium foil and neutron source will be able to supply a maximum flux of 1.5e5 fission fragments/second*cm2 to each of the PZT plates.

  20. Characteristics and direct radiative effect of mid-latitude continental aerosols: the ARM case

    Directory of Open Access Journals (Sweden)

    M. G. Iziomon

    2003-01-01

    Full Text Available A multi-year field measurement analysis of the characteristics and direct radiative effect of aerosols at the Southern Great Plains (SGP central facility of the Atmospheric Radiation Measurement (ARM Program is presented. Inter-annual mean and standard deviation of submicrometer scattering fraction (at 550 nm and Ångström exponent å (450 nm, 700 nm at the mid-latitude continental site are indicative of the scattering dominance of fine mode aerosol particles, being 0.84±0.03 and 2.25±0.09, respectively. We attribute the diurnal variation of submicron aerosol concentration to coagulation, photochemistry and the evolution of the boundary layer. Precipitation does not seem to play a role in the observed afternoon maximum in aerosol concentration. Submicron aerosol mass at the site peaks in the summer (12.1±6.7mg m-3, with the summer value being twice that in the winter. Of the chemically analyzed ionic components (which exclude carbonaceous aerosols, SO4= and NH4+ constitute the dominant species at the SGP seasonally, contributing 23-30% and 9-12% of the submicron aerosol mass, respectively. Although a minor species, there is a notable rise in NO3- mass fraction in winter. We contrast the optical properties of dust and smoke haze. The single scattering albedo w0 shows the most remarkable distinction between the two aerosol constituents. We also present aircraft measurements of vertical profiles of aerosol optical properties at the site. Annually, the lowest 1.2 km contributes 70% to the column total light scattering coefficient. Column-averaged and surface annual mean values of hemispheric backscatter fraction (at 550 nm, w0 (at 550 nm and å (450 nm, 700 nm agree to within 5% in 2001. Aerosols produce a net cooling (most pronounced in the spring at the ARM site

  1. Total-dose radiation-induced degradation of thin film ferroelectric capacitors

    International Nuclear Information System (INIS)

    Schwank, J.R.; Nasby, R.D.; Miller, S.L.; Rodgers, M.S.; Dressendorfer, P.V.

    1990-01-01

    Thin film PbZr y Ti 1-y O 3 (PZT) ferroelectric memories offer the potential for radiation-hardened, high-speed nonvolatile memories with good retention and fatigue properties. In this paper we explore in detail the radiation hardness of PZT ferroelectric capacitors. Ferroelectric capacitors were irradiated using x-ray and Co-60 sources to dose levels up to 16 Mrad(Si). The capacitors were characterized for their memory properties both before and after irradiation. The radiation hardness was process dependent. Three out of four processes resulted in capacitors that showed less than 30% radiation-induced degradation in retained polarization charge and remanent polarization after irradiating to 16 Mrad(Si). On the other hand, one of the processes showed significant radiation-induced degradation in retained polarization charge and remanent polarization at dose levels above 1 Mrad(Si). The decrease in retained polarization charge appears to be due to an alteration of the switching characteristics of the ferroelectric due to changes in the internal fields. The radiation-induced degradation is recoverable by a postirradiation biased anneal and can be prevented entirely if devices are cycled during irradiation. The authors have developed a model to simulate the observed degradation

  2. Acetone enhances the direct analysis of total condensed tannins in plant tissues by the butanol-HCl-iron assay

    Science.gov (United States)

    The butanol-HCl spectrophotometric assay is widely used to quantify extractable and insoluble forms of condensed tannin (CT, syn. proanthocyanidin) in foods, feeds, and foliage of herbaceous and woody plants. However, this method underestimates total CT content when applied directly to plant materia...

  3. Testing for causality between the foreign direct investment, current account deficit, GDP and total credit: Evidence from G7

    Directory of Open Access Journals (Sweden)

    Akbas Yusuf Ekrem

    2013-01-01

    Full Text Available In this study, countries were analyzed between 1990 and 2011 in order to determine whether a causal relationship exists among current account deficit, GDP, foreign direct investment, and total credits of G7. Analysis took into account the cross-sectional dependence and was applied to test the causality among the variables form the panel. Firstly, panel unit root tests were used for determining stationary of variables. As a result of the panel unit root tests, it was found that GDP and foreign direct investment have a stationary structure and that total credits and current account deficit contain unit root. In order to see whether there is a long-term relationship among the variables or not, the panel co-integration test was used. As a result of the test, it was concluded that there is a co-integration relationship among the series. The possibility of a causal relationship was analyzed among the variables using the causality test developed by Elena Ivona Dumitrescu and Christophe Hurlin (2012. Results of the analysis showed a unidirectional causal relationship from current account deficit and foreign direct investment to GDP. Bidirectional causality was found between current account deficit and total credits. Finally, a unidirectional relationship was found from foreign direct investment to current account deficit and total credits.

  4. Data Quality Objectives Supporting the Environmental Direct Radiation Monitoring Program for the INL Site

    Energy Technology Data Exchange (ETDEWEB)

    Lundell, J. F. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Magnuson, S. O. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Scherbinske, P. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Case, M. J. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-07-01

    This document presents the development of the data quality objectives (DQOs) for the Idaho National Laboratory (INL) Environmental Direct Radiation Monitoring Program and follows the Environmental Protection Agency (EPA) DQO process (EPA 2006). This document also develops and presents the logic to determine the specific number of direct radiation monitoring locations around INL facilities on the desert west of Idaho Falls and in Idaho Falls, at locations bordering the INL Site, and in the surrounding regional area. The selection logic follows the guidance from the Department of Energy (DOE) (2015) for environmental surveillance of DOE facilities.

  5. Application of a Pelletron accelerator to study total dose radiation effects on 50 GHz SiGe HBTs

    Energy Technology Data Exchange (ETDEWEB)

    Praveen, K.C.; Pushpa, N.; Naik, P.S. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570 006 (India); Cressler, John D. [School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA (United States); Tripathi, Ambuj [Inter University Accelerator Centre (IUAC), New Delhi 110 067 (India); Gnana Prakash, A.P., E-mail: gnanaprakash@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570 006 (India)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer Total dose effects of 50 MeV Li3+ ion on 50 GHz SiGe HBTs is investigated. Black-Right-Pointing-Pointer Ion irradiated results were compared with Co-60 gamma results. Black-Right-Pointing-Pointer 50 MeV Li ions create more damage in E-B spacer oxide when compared to Co-60 gamma radiation. Black-Right-Pointing-Pointer Co-60 gamma radiation create more damage in STI oxide when compared to 50 MeV Li ions. Black-Right-Pointing-Pointer Worst case total dose radiation effects can be studied using Pelletron accelerator facilities. - Abstract: We have investigated the effects of 50 MeV lithium ion irradiation on the DC electrical characteristics of first-generation silicon-germanium heterojunction bipolar transistors (50 GHz SiGe HBTs) in the dose range of 600 krad to 100 Mrad. The results of 50 MeV Li{sup 3+} ion irradiation on the SiGe HBTs are compared with 63 MeV proton and Co-60 gamma irradiation results in the same dose range in order to understand the damage induced by different LET species. The radiation response of emitter-base (EB) spacer oxide and shallow trench isolation (STI) oxide to different irradiation types are discussed in this paper. We have also focused on the efficacy in the application of a Pelletron accelerator to study total dose irradiation studies in SiGe HBTs.

  6. Direct aperture optimization as a means of reducing the complexity of intensity modulated radiation therapy plans

    International Nuclear Information System (INIS)

    Broderick, Maria; Leech, Michelle; Coffey, Mary

    2009-01-01

    Intensity Modulated Radiation Therapy (IMRT) is a means of delivering radiation therapy where the intensity of the beam is varied within the treatment field. This is done by dividing a large beam into many small beamlets. Dose constraints are assigned to both the target and sensitive structures and computerised inverse optimization is performed to find the individual weights of this large number of beamlets. The computer adjusts the intensities of these beamlets according to the required planning dose objectives. The optimized intensity patterns are then decomposed into a series of deliverable multi leaf collimator (MLC) shapes in the sequencing step. One of the main problems of IMRT, which becomes even more apparent as the complexity of the IMRT plan increases, is the dramatic increase in the number of Monitor Units (MU) required to deliver a fractionated treatment. The difficulty with this increase in MU is its association with increased treatment times and a greater leakage of radiation from the MLCs increasing the total body dose and the risk of secondary cancers in patients. Therefore one attempts to find ways of reducing these MU without compromising plan quality. The design of inverse planning systems where the beam is divided into small beamlets to produce the required intensity map automatically introduces complexity into IMRT treatment planning. Plan complexity is associated with many negative factors such as dosimetric uncertainty and delivery issues A large search space is required necessitating much computing power. However, the limitations of the delivery technology are not taken into consideration when designing the ideal intensity map therefore a further step termed the sequencing step is required to convert the ideal intensity map into a deliverable one. Many approaches have been taken to reduce the complexity. These include setting intensity limits, putting penalties on the cost function and using smoothing filters Direct Aperture optimization

  7. Direct aperture optimization as a means of reducing the complexity of intensity modulated radiation therapy plans

    Directory of Open Access Journals (Sweden)

    Coffey Mary

    2009-02-01

    Full Text Available Abstract Intensity Modulated Radiation Therapy (IMRT is a means of delivering radiation therapy where the intensity of the beam is varied within the treatment field. This is done by dividing a large beam into many small beamlets. Dose constraints are assigned to both the target and sensitive structures and computerised inverse optimization is performed to find the individual weights of this large number of beamlets. The computer adjusts the intensities of these beamlets according to the required planning dose objectives. The optimized intensity patterns are then decomposed into a series of deliverable multi leaf collimator (MLC shapes in the sequencing step. One of the main problems of IMRT, which becomes even more apparent as the complexity of the IMRT plan increases, is the dramatic increase in the number of Monitor Units (MU required to deliver a fractionated treatment. The difficulty with this increase in MU is its association with increased treatment times and a greater leakage of radiation from the MLCs increasing the total body dose and the risk of secondary cancers in patients. Therefore one attempts to find ways of reducing these MU without compromising plan quality. The design of inverse planning systems where the beam is divided into small beamlets to produce the required intensity map automatically introduces complexity into IMRT treatment planning. Plan complexity is associated with many negative factors such as dosimetric uncertainty and delivery issues A large search space is required necessitating much computing power. However, the limitations of the delivery technology are not taken into consideration when designing the ideal intensity map therefore a further step termed the sequencing step is required to convert the ideal intensity map into a deliverable one. Many approaches have been taken to reduce the complexity. These include setting intensity limits, putting penalties on the cost function and using smoothing filters Direct

  8. Direct aperture optimization as a means of reducing the complexity of intensity modulated radiation therapy plans

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, Maria; Leech, Michelle; Coffey, Mary [Division of Radiation Therapy, School of Medicine, Trinity College Dublin, Dublin, Ireland (United Kingdom)

    2009-02-16

    Intensity Modulated Radiation Therapy (IMRT) is a means of delivering radiation therapy where the intensity of the beam is varied within the treatment field. This is done by dividing a large beam into many small beamlets. Dose constraints are assigned to both the target and sensitive structures and computerised inverse optimization is performed to find the individual weights of this large number of beamlets. The computer adjusts the intensities of these beamlets according to the required planning dose objectives. The optimized intensity patterns are then decomposed into a series of deliverable multi leaf collimator (MLC) shapes in the sequencing step. One of the main problems of IMRT, which becomes even more apparent as the complexity of the IMRT plan increases, is the dramatic increase in the number of Monitor Units (MU) required to deliver a fractionated treatment. The difficulty with this increase in MU is its association with increased treatment times and a greater leakage of radiation from the MLCs increasing the total body dose and the risk of secondary cancers in patients. Therefore one attempts to find ways of reducing these MU without compromising plan quality. The design of inverse planning systems where the beam is divided into small beamlets to produce the required intensity map automatically introduces complexity into IMRT treatment planning. Plan complexity is associated with many negative factors such as dosimetric uncertainty and delivery issues A large search space is required necessitating much computing power. However, the limitations of the delivery technology are not taken into consideration when designing the ideal intensity map therefore a further step termed the sequencing step is required to convert the ideal intensity map into a deliverable one. Many approaches have been taken to reduce the complexity. These include setting intensity limits, putting penalties on the cost function and using smoothing filters Direct Aperture optimization

  9. Simulation and measurement of total ionizing dose radiation induced image lag increase in pinned photodiode CMOS image sensors

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jing [School of Materials Science and Engineering, Xiangtan University, Hunan (China); State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Chen, Wei, E-mail: chenwei@nint.ac.cn [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Wang, Zujun, E-mail: wangzujun@nint.ac.cn [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Xue, Yuanyuan; Yao, Zhibin; He, Baoping; Ma, Wuying; Jin, Junshan; Sheng, Jiangkun; Dong, Guantao [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China)

    2017-06-01

    This paper presents an investigation of total ionizing dose (TID) induced image lag sources in pinned photodiodes (PPD) CMOS image sensors based on radiation experiments and TCAD simulation. The radiation experiments have been carried out at the Cobalt −60 gamma-ray source. The experimental results show the image lag degradation is more and more serious with increasing TID. Combining with the TCAD simulation results, we can confirm that the junction of PPD and transfer gate (TG) is an important region forming image lag during irradiation. These simulations demonstrate that TID can generate a potential pocket leading to incomplete transfer.

  10. Cumulative total effective whole-body radiation dose in critically ill patients.

    Science.gov (United States)

    Rohner, Deborah J; Bennett, Suzanne; Samaratunga, Chandrasiri; Jewell, Elizabeth S; Smith, Jeffrey P; Gaskill-Shipley, Mary; Lisco, Steven J

    2013-11-01

    Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.

  11. Total integrated performance excellence system (TIPES): A true north direction for a clinical trial support center.

    Science.gov (United States)

    Sather, Mike R; Parsons, Sherry; Boardman, Kathy D; Warren, Stuart R; Davis-Karim, Anne; Griffin, Kevin; Betterton, Jane A; Jones, Mark S; Johnson, Stanley H; Vertrees, Julia E; Hickey, Jan H; Salazar, Thelma P; Huang, Grant D

    2018-03-01

    This paper presents the quality journey taken by a Federal organization over more than 20 years. These efforts have resulted in the implementation of a Total Integrated Performance Excellence System (TIPES) that combines key principles and practices of established quality systems. The Center has progressively integrated quality system frameworks including the Malcom Baldrige National Quality Award (MBNQA) Framework and Criteria for Performance Excellence, ISO 9001, and the Organizational Project Management Maturity Model (OPM3), as well as supplemental quality systems of ISO 15378 (packaging for medicinal products) and ISO 21500 (guide to project management) to systematically improve all areas of operations. These frameworks were selected for applicability to Center processes and systems, consistency and reinforcement of complimentary approaches, and international acceptance. External validations include the MBNQA, the highest quality award in the US, continued registration and conformance to ISO standards and guidelines, and multiple VA and state awards. With a focus on a holistic approach to quality involving processes, systems and personnel, this paper presents activities and lessons that were critical to building TIPES and establishing the quality environment for conducting clinical research in support of Veterans and national health care.

  12. Total integrated performance excellence system (TIPES: A true north direction for a clinical trial support center

    Directory of Open Access Journals (Sweden)

    Mike R. Sather

    2018-03-01

    Full Text Available This paper presents the quality journey taken by a Federal organization over more than 20 years. These efforts have resulted in the implementation of a Total Integrated Performance Excellence System (TIPES that combines key principles and practices of established quality systems. The Center has progressively integrated quality system frameworks including the Malcom Baldrige National Quality Award (MBNQA Framework and Criteria for Performance Excellence, ISO 9001, and the Organizational Project Management Maturity Model (OPM3, as well as supplemental quality systems of ISO 15378 (packaging for medicinal products and ISO 21500 (guide to project management to systematically improve all areas of operations. These frameworks were selected for applicability to Center processes and systems, consistency and reinforcement of complimentary approaches, and international acceptance. External validations include the MBNQA, the highest quality award in the US, continued registration and conformance to ISO standards and guidelines, and multiple VA and state awards. With a focus on a holistic approach to quality involving processes, systems and personnel, this paper presents activities and lessons that were critical to building TIPES and establishing the quality environment for conducting clinical research in support of Veterans and national health care.

  13. What do unsuccessful radiographs contribute to the total radiation dose to a patient

    International Nuclear Information System (INIS)

    Roth, J.; Nemec, H.W.

    1985-01-01

    Prevention of, or reduction of, unnecessary exposure to radiation is one of the prime goals of radiological protection in diagnostic radiology. The paper explains the advantages of a new approach, namely to achieve optimum focussing and adjustment of radiation sources for difficult imaging tasks by way of the fluoroscopic rather than the collimator method. The patient's exposure during this preliminary examination on the average will amount to 25 p.c. of the doses applied by the subsequent radiograph; on the other hand, this approach will reduce the number of unsuccessful pictures. (orig.) [de

  14. Calculation of radiation effects in solids by direct numerical solution of the adjoint transport equation

    International Nuclear Information System (INIS)

    Matthes, W.K.

    1998-01-01

    The 'adjoint transport equation in its integro-differential form' is derived for the radiation damage produced by atoms injected into solids. We reduce it to the one-dimensional form and prepare it for a numerical solution by: --discretizing the continuous variables energy, space and direction, --replacing the partial differential quotients by finite differences and --evaluating the collision integral by a double sum. By a proper manipulation of this double sum the adjoint transport equation turns into a (very large) set of linear equations with tridiagonal matrix which can be solved by a special (simple and fast) algorithm. The solution of this set of linear equations contains complete information on a specified damage type (e.g. the energy deposited in a volume V) in terms of the function D(i,E,c,x) which gives the damage produced by all particles generated in a cascade initiated by a particle of type i starting at x with energy E in direction c. It is essential to remark that one calculation gives the damage function D for the complete ranges of the variables {i,E,c and x} (for numerical reasons of course on grid-points in the {E,c,x}-space). This is most useful to applications where a general source-distribution S(i,E,c,x) of particles is given by the experimental setup (e.g. beam-window and and target in proton accelerator work. The beam-protons along their path through the window--or target material generate recoil atoms by elastic collisions or nuclear reactions. These recoil atoms form the particle source S). The total damage produced then is eventually given by: D = (Σ)i ∫ ∫ ∫ S(i, E, c, x)*D(i, E, c, x)*dE*dc*dx A Fortran-77 program running on a PC-486 was written for the overall procedure and applied to some problems

  15. Global source attribution of sulfate concentration and direct and indirect radiative forcing

    Directory of Open Access Journals (Sweden)

    Y. Yang

    2017-07-01

    Full Text Available The global source–receptor relationships of sulfate concentrations, and direct and indirect radiative forcing (DRF and IRF from 16 regions/sectors for years 2010–2014 are examined in this study through utilizing a sulfur source-tagging capability implemented in the Community Earth System Model (CESM with winds nudged to reanalysis data. Sulfate concentrations are mostly contributed by local emissions in regions with high emissions, while over regions with relatively low SO2 emissions, the near-surface sulfate concentrations are primarily attributed to non-local sources from long-range transport. Regional source efficiencies of sulfate concentrations are higher over regions with dry atmospheric conditions and less export, suggesting that lifetime of aerosols, together with regional export, is important in determining regional air quality. The simulated global total sulfate DRF is −0.42 W m−2, with −0.31 W m−2 contributed by anthropogenic sulfate and −0.11 W m−2 contributed by natural sulfate, relative to a state with no sulfur emissions. In the Southern Hemisphere tropics, dimethyl sulfide (DMS contributes 17–84 % to the total DRF. East Asia has the largest contribution of 20–30 % over the Northern Hemisphere mid- and high latitudes. A 20 % perturbation of sulfate and its precursor emissions gives a sulfate incremental IRF of −0.44 W m−2. DMS has the largest contribution, explaining −0.23 W m−2 of the global sulfate incremental IRF. Incremental IRF over regions in the Southern Hemisphere with low background aerosols is more sensitive to emission perturbation than that over the polluted Northern Hemisphere.

  16. Global source attribution of sulfate concentration and direct and indirect radiative forcing

    Science.gov (United States)

    Yang, Yang; Wang, Hailong; Smith, Steven J.; Easter, Richard; Ma, Po-Lun; Qian, Yun; Yu, Hongbin; Li, Can; Rasch, Philip J.

    2017-07-01

    The global source-receptor relationships of sulfate concentrations, and direct and indirect radiative forcing (DRF and IRF) from 16 regions/sectors for years 2010-2014 are examined in this study through utilizing a sulfur source-tagging capability implemented in the Community Earth System Model (CESM) with winds nudged to reanalysis data. Sulfate concentrations are mostly contributed by local emissions in regions with high emissions, while over regions with relatively low SO2 emissions, the near-surface sulfate concentrations are primarily attributed to non-local sources from long-range transport. Regional source efficiencies of sulfate concentrations are higher over regions with dry atmospheric conditions and less export, suggesting that lifetime of aerosols, together with regional export, is important in determining regional air quality. The simulated global total sulfate DRF is -0.42 W m-2, with -0.31 W m-2 contributed by anthropogenic sulfate and -0.11 W m-2 contributed by natural sulfate, relative to a state with no sulfur emissions. In the Southern Hemisphere tropics, dimethyl sulfide (DMS) contributes 17-84 % to the total DRF. East Asia has the largest contribution of 20-30 % over the Northern Hemisphere mid- and high latitudes. A 20 % perturbation of sulfate and its precursor emissions gives a sulfate incremental IRF of -0.44 W m-2. DMS has the largest contribution, explaining -0.23 W m-2 of the global sulfate incremental IRF. Incremental IRF over regions in the Southern Hemisphere with low background aerosols is more sensitive to emission perturbation than that over the polluted Northern Hemisphere.

  17. Total direct cost, length of hospital stay, institutional discharges and their determinants from rehabilitation settings in stroke patients.

    Science.gov (United States)

    Saxena, S K; Ng, T P; Yong, D; Fong, N P; Gerald, K

    2006-11-01

    Length of hospital stay (LOHS) is the largest determinant of direct cost for stroke care. Institutional discharges (acute care and nursing homes) from rehabilitation settings add to the direct cost. It is important to identify potentially preventable medical and non-medical reasons determining LOHS and institutional discharges to reduce the direct cost of stroke care. The aim of the study was to ascertain the total direct cost, LOHS, frequency of institutional discharges and their determinants from rehabilitation settings. Observational study was conducted on 200 stroke patients in two rehabilitation settings. The patients were examined for various socio-demographic, neurological and clinical variables upon admission to the rehabilitation hospitals. Information on total direct cost and medical complications during hospitalization were also recorded. The outcome variables measured were total direct cost, LOHS and discharges to institutions (acute care and nursing home facility) and their determinants. The mean and median LOHS in our study were 34 days (SD = 18) and 32 days respectively. LOHS and the cost of hospital stay were significantly correlated. The significant variables associated with LOHS on multiple linear regression analysis were: (i) severe functional impairment/functional dependence Barthel Index institutional discharges (22 to acute care and 17 to nursing homes). On multivariate analysis the significant predictors of discharges to institutions from rehabilitation hospitals were medical complications (OR = 4.37; 95% CI 1.01-12.53) and severe functional impairment/functional dependence. (OR = 5.90, 95% CI 2.32-14.98). Length of hospital stay and discharges to institutions from rehabilitation settings are significantly determined by medical complications. Importance of adhering to clinical pathway/protocol for stroke care is further discussed.

  18. Direct solar radiation on various slopes from 0 to 60 degrees north latitude.

    Science.gov (United States)

    John Buffo; Leo J. Fritschen; James L. Murphy

    1972-01-01

    Direct beam solar radiation is presented in graphical and tabular form for hourly, daily, and yearly values for seven slopes on each of 16 aspects from the Equator to 60 degrees north in 10-degree increments. Theoretical equations necessary for the calculations are given. Solar altitude and azimuth during the day and year are also presented for the same latitude.

  19. Direct Radiative Effect of Mineral Dust on the Middle East and North Africa Climate

    KAUST Repository

    Bangalath, Hamza Kunhu

    2016-01-01

    Dust-climate interaction over the Middle East and North Africa (MENA) has long been studied, as it is the "dustiest" region on earth. However, the quantitative and qualitative understanding of the role of dust direct radiative effect on MENA climate

  20. Hematologic status of mice submitted to sublethal total body irradiation with mixed neutron-gamma radiation

    International Nuclear Information System (INIS)

    Herodin, F.; Court, L.

    1989-01-01

    The hematologic status of mice exposed to sublethal whole body irradiation with mixed neutron-gamma radiation (mainly neutrons) is studied. A slight decrease of the blood cell count is still observed below 1 Gy. The recovery of bone marrow granulocyte-macrophage progenitors seems to require more time than after pure gamma irradiation [fr

  1. Future directions in combined modality therapy for rectal cancer: reevaluating the role of total mesorectal excision after chemoradiotherapy

    Directory of Open Access Journals (Sweden)

    Solanki AA

    2013-08-01

    Full Text Available Abhishek A Solanki,1 Daniel T Chang,2 Stanley L Liauw11Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL, USA; 2Department of Radiation Oncology, Stanford University, Stanford, CA, USAAbstract: Most patients who develop rectal cancer present with locoregionally advanced (T3 or node-positive disease. The standard management of locoregionally advanced rectal cancer is neoadjuvant concurrent chemoradiotherapy (nCRT, followed by radical resection (low-anterior resection or abdominoperineal resection with total mesorectal excision. Approximately 15% of patients can have a pathologic complete response (pCR at the time of surgery, indicating that some patients can have no detectable residual disease after nCRT. The actual benefit of surgery in this group of patients is unclear. It is possible that omission of surgery in these patients, termed selective nonoperative management, can limit the toxicities associated with standard, multimodal combined modality therapy without compromising disease control. In this review, we discuss the clinical experiences to date using selective nonoperative management and various attempts at escalation of nCRT to improve the number of patients who have a pCR. We also explore several clinical, laboratory, imaging, histopathologic, and genetic biomarkers that have been tested as tools to predict which patients are most likely to have a pCR after nCRT.Keywords: rectal cancer, chemoradiotherapy, total mesorectal excision, nonoperative management, organ preservation

  2. Protective effect of Asparagus racemosus root extract against lethal total - body electron beam radiation induced damage in Swiss albino mice

    International Nuclear Information System (INIS)

    Sharmila, K.P.; Bhandary, B. Satheesh Kumar; Suchetha Kumari, N.; Bhat, Vadish S.; Shetty, Jayaram; Peter, Alex John; Jose, Jerish M.; Fernandes, Ronald

    2016-01-01

    To investigate the protective effect of Asparagus Racemosus Root ethanolic extract (ARE) in Swiss albino mice against acute lethal total - body Electron beam irradiation. Swiss Albino mice were used for the assessment of radiation induced sickness and 30 day survival analysis. Survival studies were determined using the Kaplan-Meier survival curves. The maximum survival was observed in the experimental mice pretreated with 200 mg/kg.b.wt. of ARE which also reduced the radiation sickness characteristics. This dose was considered as an optimal dose for radioprotection. Treatment of mice with ARE before irradiation delayed the onset of mortality as compared with the untreated irradiated controls. Present findings demonstrate the potential of ARE in mitigating radiation-induced mortality, which may be attributed to its free radical scavenging and increased antioxidant potential

  3. Radiation-induced germ-line mutations detected by a direct comparison of parents and children DNA sequences containing SNPs

    International Nuclear Information System (INIS)

    Morimyo, M.; Hongo, E.; Higashi, T.; Wu, J.; Matsumoto, I.; Okamoto, M.; Kawano, A.; Tsuji, S.

    2003-01-01

    Full text: Germ-line mutation is detected in mice but not in humans. To estimate genetic risk of humans, a new approach to extrapolate from animal data to humans or to directly detect radiation-induced mutations in man is expected. We have developed a new method to detect germ-line mutations by directly comparing DNA sequences of parents and children. The nucleotide sequences among mouse strains are almost identical except SNP markers that are detected at 1/1000 frequency. When gamma-irradiated male mice are mated with female mice, heterogeneous nucleotide sequences induced in children DNA are a candidate of mutation, whose assignment can be done by SNP analysis. This system can easily detect all types of mutations such as transition, transversion, frameshift and deletion induced by radiation and can be applied to humans having genetically heterogeneous nucleotide sequences and many SNP markers. C3H male mice of 8 weeks of gestation were irradiated with gamma rays of 3 and 1 Gy and after 3 weeks, they were mated with the same aged C57BL female mice. After 3 weeks breeding, DNA was extracted from parents and children mice. The nucleotide sequences of 150 STS markers containing 300-900 bp and SNPs of parents and children DNA were determined by a direct sequencing; amplification of STS markers by Taq DNA polymerase, purification of PCR products, and DNA sequencing with a dye-terminator method. At each radiation dose, a total amount of 5 Mb DNA sequences were examined to detect radiation-induced mutations. We could find 6 deletions in 3 Gy irradiated mice but not in 1 Gy and control mice. The mutation frequency was about 4.0 x 10 -7 /bp/ Gy or 1.6 x 10 -4 /locus/Gy, and suggested the non-linear increase of mutation rate with dose

  4. Contribution of anthropogenic aerosols in direct radiative forcing and atmospheric heating rate over Delhi in the Indo-Gangetic Basin.

    Science.gov (United States)

    Srivastava, Atul K; Singh, Sachchidanand; Tiwari, S; Bisht, D S

    2012-05-01

    The present work is aimed to understand direct radiation effects due to aerosols over Delhi in the Indo-Gangetic Basin (IGB) region, using detailed chemical analysis of surface measured aerosols during the year 2007. An optically equivalent aerosol model was formulated on the basis of measured aerosol chemical compositions along with the ambient meteorological parameters to derive radiatively important aerosol optical parameters. The derived aerosol parameters were then used to estimate the aerosol direct radiative forcing at the top of the atmosphere, surface, and in the atmosphere. The anthropogenic components measured at Delhi were found to be contributing ∼ 72% to the composite aerosol optical depth (AOD(0.5) ∼ 0.84). The estimated mean surface and atmospheric forcing for composite aerosols over Delhi were found to be about -69, -85, and -78 W m(-2) and about +78, +98, and +79 W m(-2) during the winter, summer, and post-monsoon periods, respectively. The anthropogenic aerosols contribute ∼ 90%, 53%, and 84% to the total aerosol surface forcing and ∼ 93%, 54%, and 88% to the total aerosol atmospheric forcing during the above respective periods. The mean (± SD) surface and atmospheric forcing for composite aerosols was about -79 (± 15) and +87 (± 26) W m(-2) over Delhi with respective anthropogenic contributions of ∼ 71% and 75% during the overall period of observation. Aerosol induced large surface cooling, which was relatively higher during summer as compared to the winter suggesting an increase in dust loading over the station. The total atmospheric heating rate at Delhi averaged during the observation was found to be 2.42  ±  0.72 K day(-1), of which the anthropogenic fraction contributed as much as ∼ 73%.

  5. Some totals of hygienic researches of foodstuffs treated by ionizing radiation for extention of storing terms

    International Nuclear Information System (INIS)

    Zajtsev, A.N.; Schillinger, Yu.I.; Kamal'dinova, Z.M.

    1974-01-01

    Some results of hygienic studies of food products exposed to ionizing radiation to prolong their storage life are presented. The study concerned foods treated in order to prevent germination (potato, onion), for disinfection purposes (grain, dry groat concentrates), or to inhibit microorganisms (uncooked and cooked products prepared from beef and pork, chicken carcasses, raw and gamma-ray-preserved fish, fresh fruits and berries). (E.T.)

  6. 85Kr management trade-offs: a perspective to total radiation dose commitment

    Energy Technology Data Exchange (ETDEWEB)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for /sup 85/Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether /sup 85/Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person (<0.001% of natural background radiation for the same time period).

  7. Preliminary Radiation Analysis of the Total Ionizing Dose for the Resource Prospector Mission

    Science.gov (United States)

    Rojdev, Kristina; Tylka, Allan J.; Atwell, William

    2015-01-01

    NASA's Resource Prospector (RP) is a collaborative project between multiple centers and institutions to search for volatiles at the polar regions of the Moon as a potential resource for oxygen and propellant production. The mission is rated Class D and will be the first In-Situ Resource Utilization (ISRU) demonstration on the lunar surface and at the lunar poles. Given that this mission is rated Class D, the project is considering using commercial off the shelf (COTS) electronics parts to reduce cost. However, COTS parts can be more susceptible to space radiation than typical aerospace electronic parts and carry some additional risk. Thus, prior to parts selection, having a better understanding of the radiation environment can assist designers in the parts selection process. The focus of this paper is to provide a preliminary analysis of the radiation environment from launch, through landing on the surface, and some surface stay as an initial step in determining worst case mission doses to assist designers in screening out electronic parts that would not meet the potential dose levels experienced on this mission.

  8. A novel automated direct measurement method for total antioxidant capacity using a new generation, more stable ABTS radical cation.

    Science.gov (United States)

    Erel, Ozcan

    2004-04-01

    To develop a novel colorimetric and automated direct measurement method for total antioxidant capacity (TAC). A new generation, more stable, colored 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid radical cation (ABTS(*+)) was employed. The ABTS(*+) is decolorized by antioxidants according to their concentrations and antioxidant capacities. This change in color is measured as a change in absorbance at 660 nm. This process is applied to an automated analyzer and the assay is calibrated with Trolox. The novel assay is linear up to 6 mmol Trolox equivalent/l, its precision values are lower than 3%, and there is no interference from hemoglobin, bilirubin, EDTA, or citrate. The method developed is significantly correlated with the Randox- total antioxidant status (TAS) assay (r = 0.897, P total antioxidant capacity.

  9. Modeling hemispherical and directional radiative fluxes in regular-clumped canopies

    International Nuclear Information System (INIS)

    Begue, A.

    1992-01-01

    A model of radiative transfer in regular-clumped canopies is presented. The canopy is approximated by an array of porous cylinders located at the vertices of equilateral triangles. The model is split into two submodels, each describing a different level of structure: 1) The macrostructure submodel is based on Brown and Pandolfo (1969), who applied geometrical optics theory to an array of opaque cylinders. This model is adapted for porous cylinders and is used to derive expressions for directional interception efficiency as a function of height, radius, spacing and porosity of the cylinders. 2) The microstructure submodel makes use of the average canopy transmittance theory, applied to a cylinder, to compute the porosity of the clumps as a function of the leaf area density, the leaf inclination distribution function, the dimensions of the cylinder (height and radius), and the transmittance of green leaves in the appropriate spectral band. It is shown that, in the case of erectophile plant stands, the daily porosity of the cylinder can be approximated by the porosity calculated using the extinction coefficient of diffuse radiation. Directional interception efficiency, geometric conditions (incidence/viewing), and landscape component reflectances are used to compute hemispherical (interception, absorption, and reflectance) and directional (reflectance) radiative fluxes from simple analytical formulae. This model is validated against a data set of biological, radiative (PAR region) and radiometric (SPOT channels) measurements, collected in Niger on pearl millet (Pennisetum typhoides). The model fits the data quite well in terms of hourly and daily single-band or combined (NDVI) radiative fluxes. Close correspondence to measured fluxes, using few parameters, and the possibility of inversion makes the present model a valuable tool for the study of radiative transfer in discontinuous canopies. (author)

  10. New Modeling Approaches to Study DNA Damage by the Direct and Indirect Effects of Ionizing Radiation

    Science.gov (United States)

    Plante, Ianik; Cucinotta, Francis A.

    2012-01-01

    DNA is damaged both by the direct and indirect effects of radiation. In the direct effect, the DNA itself is ionized, whereas the indirect effect involves the radiolysis of the water molecules surrounding the DNA and the subsequent reaction of the DNA with radical products. While this problem has been studied for many years, many unknowns still exist. To study this problem, we have developed the computer code RITRACKS [1], which simulates the radiation track structure for heavy ions and electrons, calculating all energy deposition events and the coordinates of all species produced by the water radiolysis. In this work, we plan to simulate DNA damage by using the crystal structure of a nucleosome and calculations performed by RITRACKS. The energy deposition events are used to calculate the dose deposited in nanovolumes [2] and therefore can be used to simulate the direct effect of the radiation. Using the positions of the radiolytic species with a radiation chemistry code [3] it will be possible to simulate DNA damage by indirect effect. The simulation results can be compared with results from previous calculations such as the frequencies of simple and complex strand breaks [4] and with newer experimental data using surrogate markers of DNA double ]strand breaks such as . ]H2AX foci [5].

  11. Radiation Protection Of Outside Workers: Implementation Of The EC Council Directive 90/641/EURATOM

    International Nuclear Information System (INIS)

    Jannsens, A.; Schnuer, K.; Naegele, J.; Lefaure, C.; Vaillant, L.

    2006-01-01

    In the beginning of the 1980's, the problem of radiological protection of workers belonging to contracted companies (undertakings) within nuclear facilities was raised. In most of the nuclear facilities, the so-called outside workers received 80% (and even more) of the collective dose, and quite often higher individual doses than workers permanently employed by the nuclear operators. Since the outside workers radiation protection issue was not explicitly taken into account by the 1980 European Basic Safety Standards Directive, there was a need for an additional piece of European radiation protection legislation. In this context, the European Union adopted in 1990 the Council Directive 90/641/EURATOM on the radiological protection of outside workers. This Directive shall ensure at European Union level that the radiological protection situation for the outside workers is equivalent to that offered to those workers permanently employed by the operators of nuclear facilities. Since the adoption of the Directive in 1990 the geographical situation of the European Union has changed significantly. At the same time, an evolution took place in the industrial structures of the nuclear industry followed by changes of employment conditions. Furthermore, new European radiation protection requirements were issued considering scientific and technical developments in the radiological protection field and laid down in the new radiation Protection Basic Safety Standards Directive 96/29/EURATOM. Taking into account these aspects the Radiation Protection Unit of the European Commission Directorate General for Energy and Transport decided to investigate the current situation and the future status of the Outside Workers Directive 90/641/EURATOM. The European Commission Radiation Protection Unit thus awarded the CEPN with a contract in order to evaluate through a survey the level of regulatory, administrative and operational implementation of Directive 90/641/EURATOM into Member States

  12. Radiation Protection Of Outside Workers: Implementation Of The EC Council Directive 90/641/EURATOM

    Energy Technology Data Exchange (ETDEWEB)

    Jannsens, A.; Schnuer, K.; Naegele, J. [European Commission, DG Energy and Transport B. EUROFORUM, 4455, L-2920 (Luxembourg); Lefaure, C.; Vaillant, L. [Nuclear Protection Evaluation Centre (CEPN) Batiment Expansion 10000, 28 rue de la Redoute, 92263 Fontenay-aux- Roses (France)

    2006-07-01

    In the beginning of the 1980's, the problem of radiological protection of workers belonging to contracted companies (undertakings) within nuclear facilities was raised. In most of the nuclear facilities, the so-called outside workers received 80% (and even more) of the collective dose, and quite often higher individual doses than workers permanently employed by the nuclear operators. Since the outside workers radiation protection issue was not explicitly taken into account by the 1980 European Basic Safety Standards Directive, there was a need for an additional piece of European radiation protection legislation. In this context, the European Union adopted in 1990 the Council Directive 90/641/EURATOM on the radiological protection of outside workers. This Directive shall ensure at European Union level that the radiological protection situation for the outside workers is equivalent to that offered to those workers permanently employed by the operators of nuclear facilities. Since the adoption of the Directive in 1990 the geographical situation of the European Union has changed significantly. At the same time, an evolution took place in the industrial structures of the nuclear industry followed by changes of employment conditions. Furthermore, new European radiation protection requirements were issued considering scientific and technical developments in the radiological protection field and laid down in the new radiation Protection Basic Safety Standards Directive 96/29/EURATOM. Taking into account these aspects the Radiation Protection Unit of the European Commission Directorate General for Energy and Transport decided to investigate the current situation and the future status of the Outside Workers Directive 90/641/EURATOM. The European Commission Radiation Protection Unit thus awarded the CEPN with a contract in order to evaluate through a survey the level of regulatory, administrative and operational implementation of Directive 90/641/EURATOM into Member

  13. Direct Collapse to Supermassive Black Hole Seeds with Radiative Transfer: Isolated Halos

    Science.gov (United States)

    Luo, Yang; Ardaneh, Kazem; Shlosman, Isaac; Nagamine, Kentaro; Wise, John H.; Begelman, Mitchell C.

    2018-05-01

    Direct collapse within dark matter haloes is a promising path to form supermassive black hole seeds at high redshifts. The outer part of this collapse remains optically thin. However, the innermost region of the collapse is expected to become optically thick and requires to follow the radiation field in order to understand its evolution. So far, the adiabatic approximation has been used exclusively for this purpose. We apply radiative transfer in the flux-limited diffusion (FLD) approximation to solve the evolution of coupled gas and radiation for isolated haloes. We find that (1) the photosphere forms at 10-6 pc and rapidly expands outwards. (2) A central core forms, with a mass of 1 M⊙, supported by gas pressure gradients and rotation. (3) Growing gas and radiation pressure gradients dissolve it. (4) This process is associated with a strong anisotropic outflow; another core forms nearby and grows rapidly. (5) Typical radiation luminosity emerging from the photosphere is 5 × 1037-5 × 1038 erg s-1, of the order the Eddington luminosity. (6) Two variability time-scales are associated with this process: a long one, which is related to the accretion flow within the central 10-4-10-3 pc, and 0.1 yr, related to radiation diffusion. (7) Adiabatic models evolution differs profoundly from that of the FLD models, by forming a geometrically thick disc. Overall, an adiabatic equation of state is not a good approximation to the advanced stage of direct collapse, because the radiation is capable of escaping due to anisotropy in the optical depth and associated gradients.

  14. Diurnal cycle of the dust instantaneous direct radiative forcing over the Arabian Peninsula

    KAUST Repository

    Osipov, Sergey

    2015-08-27

    In this study we attempted to better quantify radiative effects of dust over the Arabian Peninsula and their dependence on input parameters. For this purpose we have developed a stand-alone column radiation transport model coupled with the Mie, T-matrix and geometric optics calculations and driven by reanalysis meteorological fields and atmospheric composition. Numerical experiments were carried out for a wide range of aerosol optical depths, including extreme values developed during the dust storm on 18–20 March 2012. Comprehensive ground-based observations and satellite retrievals were used to estimate aerosol optical properties, validate calculations and carry out radiation closure. The broadband surface albedo, fluxes at the bottom and top of the atmosphere as well as instantaneous dust radiative forcing were estimated both from the model and observations. Diurnal cycle of the shortwave instantaneous dust direct radiative forcing was studied for a range of aerosol and surface characteristics representative of the Arabian Peninsula. Mechanisms and parameters responsible for diurnal variability of the radiative forcing were evaluated. We found that intrinsic variability of the surface albedo and its dependence on atmospheric conditions, along with anisotropic aerosol scattering, are mostly responsible for diurnal effects.

  15. Phase-II trial of fractionated total body radiation in bone marrow transplantation for acute leukemia

    International Nuclear Information System (INIS)

    Gale, R.P.; Opelz, G.; Feig, S.

    1979-01-01

    The addition of low doses of fractionated total body irradiation and a radiosensitizing agent to more conventional doses of total body irradiation was well tolerated but did not improve the antileukemic effect. The DAFT regimen was not associated with a higher incidence of GVHD or interstitial pneumonitis. This observation has led us to consider escalation of the dose of FTBI in our next clinical trial

  16. Concentration of total proteins in blood plasma of chickens hatched from irradiated eggs with low dose gamma radiation

    International Nuclear Information System (INIS)

    Vilic, M.; Kraljevic, P.; Miljanic, S.; Simpraga, M.

    2005-01-01

    It is known that low-dose ionising radiation may have stimulating effects on chickens. Low doses may also cause changes in the concentration of blood plasma total proteins, glucose and cholesterol in chickens. This study investigates the effects of low dose gamma-radiation on the concentration of total proteins in the blood plasma of chickens hatched from eggs irradiated with a dose of 0.15 Gy on incubation days 7 and 19. Results were compared with the control group (chickens hatched from non-irradiated eggs). After hatching, all other conditions were the same for both groups. Blood samples were drawn from the heart, and later from the wing vein on days 1, 3, 5, 7,10, 20, 30 and 42. The concentration of total proteins was determined spectrophotometrically using Boehringer Mannheim GmbH optimised kits. The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 7 showed a statistically significant decrease on the sampling day 3 (P less than 0.05) and 7 (P less than 0.01). The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 19 showed a statistically significant increase only on sampling day 1 (P less than 0.05). These results suggest that exposure of eggs to 0.15 Gy of gamma-radiation on the 7th and 19th day of incubation could produce different effects on the protein metabolism in chickens.(author)

  17. AD620SQ/883B Total Ionizing Dose Radiation Lot Acceptance Report for RESTORE-LEO

    Science.gov (United States)

    Burton, Noah; Campola, Michael

    2017-01-01

    A Radiation Lot Acceptance Test was performed on the AD620SQ/883B, Lot 1708D, in accordance with MIL-STD-883, Method 1019, Condition D. Using a Co-60 source 4 biased parts and 4 unbiased parts were irradiated at 10 mrad/s (0.036 krad/hr) in intervals of approximately 1 krad from 3-10 krads, and ones of 5 krads from 10-25 krads, where it was annealed while unbiased at 25 degrees Celsius, for 2 days, and then, subsequently, annealed while biased at 25 degrees celsius, for another 7 days.

  18. 85Kr management trade-offs: a perspective to total radiation dose commitment

    International Nuclear Information System (INIS)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for 85 Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether 85 Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person

  19. Design and investigation of planar technology based ultra-wideband antenna with directional radiation patterns

    Energy Technology Data Exchange (ETDEWEB)

    Meena, M. L., E-mail: madan.meena.ece@gamil.com; Parmar, Girish, E-mail: girish-parmar2002@yahoo.com; Kumar, Mithilesh, E-mail: mith-kr@yahoo.com [Department of Electronics Engineering, Rajasthan Technical University, Kota (India)

    2016-03-09

    A novel design technique based on planar technology for ultra-wideband (UWB) antennas with different ground shape having directional radiation pattern is being presented here. Firstly, the L-shape corner reflector ground plane antenna is designed with microstrip feed line in order to achieve large bandwidth and directivity. Thereafter, for the further improvement in the directivity as well as for better impedance matching the parabolic-shape ground plane has been introduced. The coaxial feed line is given for the proposed directional antenna in order to achieve better impedance matching with 50 ohm transmission line. The simulation analysis of the antenna is done on CST Microwave Studio software using FR-4 substrate having thickness of 1.6 mm and dielectric constant of 4.4. The simulated result shows a good return loss (S11) with respect to -10 dB. The radiation pattern characteristic, angular width, directivity and bandwidth performance of the antenna have also been compared at different resonant frequencies. The designed antennas exhibit low cost, low reflection coefficient and better directivity in the UWB frequency band.

  20. Global, direct and diffuse solar radiation on horizontal and tilted surfaces in Jeddah, Saudi Arabia

    International Nuclear Information System (INIS)

    El-Sebaii, A.A.; Al-Hazmi, F.S.; Al-Ghamdi, A.A.; Yaghmour, S.J.

    2010-01-01

    The measured data of global and diffuse solar radiation on a horizontal surface, the number of bright sunshine hours, mean daily ambient temperature, maximum and minimum ambient temperatures, relative humidity and amount of cloud cover for Jeddah (lat. 21 o 42'37''N, long. 39 o 11'12''E), Saudi Arabia, during the period (1996-2007) are analyzed. The monthly averages of daily values for these meteorological variables have been calculated. The data are then divided into two sets. The sub-data set I (1996-2004) are employed to develop empirical correlations between the monthly average of daily global solar radiation fraction (H/H 0 ) and the various weather parameters. The sub-data set II (2005-2007) are then used to evaluate the derived correlations. Furthermore, the total solar radiation on horizontal surfaces is separated into the beam and diffuses components. Empirical correlations for estimating the diffuse solar radiation incident on horizontal surfaces have been proposed. The total solar radiation incident on a tilted surface facing south H t with different tilt angles is then calculated using both Liu and Jordan isotropic model and Klucher's anisotropic model. It is inferred that the isotropic model is able to estimate H t more accurate than the anisotropic one. At the optimum tilt angle, the maximum value of H t is obtained as ∼36 (MJ/m 2 day) during January. Comparisons with 22 years average data of NASA SSE Model showed that the proposed correlations are able to predict the total annual energy on horizontal and tilted surfaces in Jeddah with a reasonable accuracy. It is also found that at Jeddah, the solar energy devices have to be tilted to face south with a tilt angle equals the latitude of the place in order to achieve the best performance all year round.

  1. Total reflection X-ray fluorescence with synchrotron radiation applied to biological and environmental samples

    International Nuclear Information System (INIS)

    Simabuco, S.M.; Matsumoto, E.; Jesus, E.F.O.; Lopes, R.T.; Perez, C.; Nascimento Filho, V.F.; Costa, R.S.S.; Tavares do Carmo, M.G.; Saunders, C.

    2001-01-01

    Full text: The Total Reflection X-ray Fluorescence has been applied for trace elements in water and aqueous solutions, environmental samples and biological materials after sample preparation and to surface analysis of silicon wafers. The present paper shows some results of applications for rainwater, atmospheric particulate material, colostrum and nuclear samples. (author)

  2. Apparatus and method for locating and quantifying or directing a source of ionizing radiation

    International Nuclear Information System (INIS)

    Rogers, W.L.; Wainstock, M.A.

    1976-01-01

    An apparatus and method for locating or directing a source of ionizing radiation such as X-rays, gamma rays, alpha particles, beta particles, etc. are described. The preferred embodiment detects and locates abnormalities of the body such as ocular melanomas by detecting the emission of radiation from a melanoma which has absorbed a radioactive medium. The apparatus includes an ultrasound probe which emits ultrasonic waves along a first axis and detects a returned portion of the waves. The ultrasound probe is associated with a display which displays the returned portion of the waves in the time domain so that suspected abnormalities can be located. The ultrasound probe is used to guide a directional probe for detecting and quantifying ionizing radiation which is equipped with a focusing collimator having a focal point along a second axis. The two probes are supported so that the first and second axes converge at the focal point of the collimator. A range marker is associated with the ultrasonic detector which indicates the point of convergence of the axes on the ultrasonic display permitting guidance of the radiation detecting probe to the suspected abnormality

  3. Directives and recommendations of the European Communities on health protection against ionizing radiations

    International Nuclear Information System (INIS)

    1977-11-01

    The CNEN has published a third edition, with comments, of the Directives and Recommendations of the European Communities on health protection against ionizing radiations, following their revision in 1976. This revision takes account of recent developments in the ICRP recommendations which serve as guidelines in the legislation of many countries for establishing general radiation protection principles as well as basic criteria and technical standards. The new Directive, while keeping to the basic principles established in 1959, introduces new methods for improved medical surveillance of workers; also, the previous difference between occupationally exposed workers and those occasionally exposed is eliminated. Finally, a new concept of critical groups is introduced as regards protection of the population, as a basis for its protection. (NEA) [fr

  4. Directional radiation of Babinet-inverted optical nanoantenna integrated with plasmonic waveguide

    Science.gov (United States)

    Kim, Jineun; Roh, Young-Geun; Cheon, Sangmo; Jeong Kim, Un; Hwang, Sung Woo; Park, Yeonsang; Lee, Chang-Won

    2015-07-01

    We present a Babinet-inverted optical nanoantenna integrated with a plasmonic waveguide. Using an integrated nanoantenna, we can couple the plasmon guide mode in a metal-insulator-metal (MIM) structure into the resonant antenna feed directly. The resonantly excited feed slot then radiates to free space and generates a magnetic dipole-like far-field pattern. The coupling efficiency of the integrated nanoantenna is calculated as being approximately 19% using a three-dimensional finite-difference time-domain (3D FDTD) simulation. By adding an auxiliary groove structure along with the feed, the radiation direction can be controlled similar to an optical Yagi-Uda antenna. We also determine, both theoretically and experimentally, that groove depth plays a significant role to function groove structure as a reflector or a director. The demonstrated Babinet-inverted optical nanoantenna integrated with a plasmonic waveguide can be used as a “plasmonic via” in plasmonic nanocircuits.

  5. Radiation resistant PIDECα cell using photon intermediate direct energy conversion and a 210Po source.

    Science.gov (United States)

    Weaver, Charles L; Schott, Robert J; Prelas, Mark A; Wisniewski, Denis A; Rothenberger, Jason B; Lukosi, Eric D; Oh, Kyuhak

    2018-02-01

    Radiation damage is a significant concern with both alphavoltaic and betavoltaic cells because their performance degrades, especially with high-energy - (>200keV) beta and alpha particles. Indirect excitation methods, such as the Photon Intermediate Direct Energy Conversion (PIDEC) framework, can protect the transducer from radiation. A nuclear battery using a 90 Sr beta source was constructed by the author's research group, which demonstrated the radiation resistance of a PIDEC cell driven by beta particles (PIDECβ cell). Use of alpha sources to drive nuclear batteries would appear to be much more attractive than beta sources due to higher potential power density. However, they are also subject to higher rates of radiation damage. This paper describes the successful incorporation of alpha particles into the PIDEC framework using the alpha emitter 210 Po to form a PIDECα cell. The PIDECα cell transducer was exposed to alpha particles for over one year without experiencing adverse effects from radiation damage. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. The direct radiative effect of biomass burning aerosols over southern Africa

    Directory of Open Access Journals (Sweden)

    S. J. Abel

    2005-01-01

    Full Text Available A multi-column radiative transfer code is used to assess the direct radiative effect of biomass burning aerosols over the southern African region during September. The horizontal distribution of biomass smoke is estimated from two sources; i General Circulation Model (GCM simulations combined with measurements from the Aerosol Robotic Network (AERONET of Sun photometers; ii data from the Moderate resolution Imaging Spectrometer (MODIS satellite. Aircraft and satellite measurements are used to constrain the cloud fields, aerosol optical properties, vertical structure, and land surface albedo included in the model. The net regional direct effect of the biomass smoke is -3.1 to -3.6 Wm-2 at the top of atmosphere, and -14.4 to -17.0 Wm-2 at the surface for the MODIS and GCM distributions of aerosol. The direct radiative effect is shown to be highly sensitive to the prescribed vertical profiles and aerosol optical properties. The diurnal cycle of clouds and the spectral dependency of surface albedo are also shown to play an important role.

  7. Effect of dietary protein quality on the resistance of rats to total body radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bounous, G.; Pageau, R.

    1983-02-01

    Young rats have been fed four defined-formula diets before and after ..gamma..-irradiation (700 rd (7.0 Gy), 75 rd/min (750 mGy), 80 cm from the source, total body). Animals eating a diet containing lactalbumin hydrolyzate (20 g/100 g diet) exhibited less anorexia and weight loss following ..gamma..-rays than a corresponding group eating casein hydrolyzate (20 g/100 g diet).

  8. Noise reduction technology reduces radiation dose in chronic total occlusions percutaneous coronary intervention: a propensity score-matched analysis.

    Science.gov (United States)

    Maccagni, Davide; Benincasa, Susanna; Bellini, Barbara; Candilio, Luciano; Poletti, Enrico; Carlino, Mauro; Colombo, Antonio; Azzalini, Lorenzo

    2018-03-23

    Chronic total occlusions (CTO) percutaneous coronary intervention (PCI) is associated with high radiation dose. Our study aim was to evaluate the impact of the implementation of a noise reduction technology (NRT) on patient radiation dose during CTO PCI. A total of 187 CTO PCIs performed between February 2016 and May 2017 were analyzed according to the angiographic systems utilized: Standard (n = 60) versus NRT (n = 127). Propensity score matching (PSM) was performed to control for differences in baseline characteristics. Primary endpoints were Cumulative Air Kerma at Interventional Reference Point (AK at IRP), which correlates with patient's tissue reactions; and Kerma Area Product (KAP), a surrogate measure of patient's risk of stochastic radiation effects. An Efficiency Index (defined as fluoroscopy time/AK at IRP) was calculated for each procedure. Image quality was evaluated using a 5-grade Likert-like scale. After PSM, n = 55 pairs were identified. Baseline and angiographic characteristics were well matched between groups. Compared to the Standard system, NRT was associated with lower AK at IRP [2.38 (1.80-3.66) vs. 3.24 (2.04-5.09) Gy, p = 0.035], a trend towards reduction for KAP [161 (93-244) vs. 203 (136-363) Gycm 2 , p = 0.069], and a better Efficiency Index [16.75 (12.73-26.27) vs. 13.58 (9.92-17.63) min/Gy, p = 0.003]. Image quality was similar between the two groups (4.39 ± 0.53 Standard vs. 4.34 ± 0.47 NRT, p = 0.571). In conclusion, compared with a Standard system, the use of NRT in CTO PCI is associated with lower patient radiation dose and similar image quality.

  9. Testing and analysis on total protein, albumin and A/G of salivary in radiation exposure persons

    International Nuclear Information System (INIS)

    Wang Jun; Zhang Yan; Li Guangwen; Li Gang; Guo Jing; Li Hui; Wang Yuxin; Li Cuixia

    2012-01-01

    Objective: To study the oral health effect of long term low dose radiation on exposure personnel and to provide a basis for further improving the protection ability. Methods: Testing method, which was based on APT and HSA interactions induced by synchronous fluorescence specific changes, and intensity and concentrations of HSA in the solution in the system of synchronous fluorescence showed a good linear relations. the establishment of a APT as a molecular probe was used to test concentration of salivary total protein (TP), albumin (ALB), globulin (GLO) and albumin by synchronous fluorescence spectrum analysis. The information was analyzed in Foxpro 6.0 and SPSS 16.0 software. Result: Protein (TP) Mean Value was 3.904 ±1.369 g/L, Minimum Value was 0.30 g/L and Maximum Value was 7.50 g/L. Albumin (ALB) Mean Value was 0.965±0.665 g/L, Minimum Value was 0.09 g/L and Maximum Value was 3.98 g/L. Globulin (GLO) Mean Value was 2.895±0.947 g/L, Minimum Value was 0.01 g/L and Maximum Value was 5.81 g/L. A/G Mean Value was 0.327. Conclusion: Long term and low dose of radiation would break the chronic physiological balance and concentration of salivary total protein (TP), albumin (ALB), globulin (GLO) and albumin and globulin ratio (A/G) changed obviously. It was necessary to do more special oral health care, further improve the individual protection consciousness, strengthen the radiation monitoring and protection measures, improve the regulation system, and reduce radiation damage on special personnel health significantly. (authors)

  10. Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range

    Science.gov (United States)

    Zuber, Ralf; Sperfeld, Peter; Riechelmann, Stefan; Nevas, Saulius; Sildoja, Meelis; Seckmeyer, Gunther

    2018-04-01

    A compact array spectroradiometer that enables precise and robust measurements of solar UV spectral direct irradiance is presented. We show that this instrument can retrieve total ozone column (TOC) accurately. The internal stray light, which is often the limiting factor for measurements in the UV spectral range and increases the uncertainty for TOC analysis, is physically reduced so that no other stray-light reduction methods, such as mathematical corrections, are necessary. The instrument has been extensively characterised at the Physikalisch-Technische Bundesanstalt (PTB) in Germany. During an international total ozone measurement intercomparison at the Izaña Atmospheric Observatory in Tenerife, the high-quality applicability of the instrument was verified with measurements of the direct solar irradiance and subsequent TOC evaluations based on the spectral data measured between 12 and 30 September 2016. The results showed deviations of the TOC of less than 1.5 % from most other instruments in most situations and not exceeding 3 % from established TOC measurement systems such as Dobson or Brewer.

  11. Angles of total shifts and angles of maxumum crop during development of faces diagonal to seam strike directions

    Directory of Open Access Journals (Sweden)

    Н. А. Колесник

    2017-06-01

    Full Text Available When predicting deformations and determining measures to protect underworked objects, angular parameters are used: the boundary angles, the angles of total shift, the angle of maximum crop. The values of these angular parameters are given in the normative documents, but only for sections across and along the strike of the formation. However, at present, longwall face mining is mainly being carried out along a diagonal direction to the strike of the formation. In connection with this, the determination of the values of the angular parameters for such conditions is a topical task.The method of determination and the analytical dependences of the angles of total shifts and angles of maximum crop in sections of the longitudinal and transverse axes of coal-mining faces developed along diagonal directions to the strike of the formation are proposed. These angular parameters are used for prognosis of deformations of the earth's surface and for determining the characteristic zones of influence of mine workings on the local places.

  12. Direct Collapse to Supermassive Black Hole Seeds with Radiation Transfer: Cosmological Halos

    Science.gov (United States)

    Ardaneh, Kazem; Luo, Yang; Shlosman, Isaac; Nagamine, Kentaro; Wise, John H.; Begelman, Mitchell C.

    2018-06-01

    We have modeled direct collapse of a primordial gas within dark matter halos in the presence of radiative transfer, in high-resolution zoom-in simulations in a cosmological framework, down to the formation of the photosphere and the central object. Radiative transfer has been implemented in the flux-limited diffusion (FLD) approximation. Adiabatic models were run for comparison. We find that (a) the FLD flow forms an irregular central structure and does not exhibit fragmentation, contrary to adiabatic flow which forms a thick disk, driving a pair of spiral shocks, subject to Kelvin-Helmholtz shear instability forming fragments; (b) the growing central core in the FLD flow quickly reaches ˜10 M⊙ and a highly variable luminosity of 1038 - 1039 erg s-1, comparable to the Eddington luminosity. It experiences massive recurrent outflows driven by radiation force and thermal pressure gradients, which mix with the accretion flow and transfer the angular momentum outwards; and (c) the interplay between these processes and a massive accretion, results in photosphere at ˜10 AU. We conclude that in the FLD model (1) the central object exhibits dynamically insignificant rotation and slower than adiabatic temperature rise with density; (2) does not experience fragmentation leading to star formation, thus promoting the fast track formation of a supermassive black hole (SMBH) seed; (3) inclusion of radiation force leads to outflows, resulting in the mass accumulation within the central 10-3 pc, which is ˜100 times larger than characteristic scale of star formation. The inclusion of radiative transfer reveals complex early stages of formation and growth of the central structure in the direct collapse scenario of SMBH seed formation.

  13. A Study of Direct and Cloud-Mediated Radiative Forcing of Climate Due to Aerosols

    Science.gov (United States)

    Yu, Shao-Cai

    1999-01-01

    radiative properties to aerosol composition, size distribution, relative humidity (RH) is examined for the following aerosol systems: inorganic and organic ions (Cl-, Br-, NO3 -, SO4 2-, Na+, NH4 +, K+, Ca2+, Mg2+, HCOO-, CH3COO-, CH3CH2COO-, CH3COCOO-, OOCCOO2-, MSA-1); water-insoluble inorganic and organic compounds (elemental carbon, n-alkanes, SiO2, Al2O3, Fe2O3 and other organic compounds). The partial molar refraction method was used to calculate the real part of the refractive index. It was found that the asymmetry factor increased by approximately 48% with the real part varying from 1.40 to 1.65, and the single scattering albedo decreased by 24% with the imaginary part varying from -0.005 to -0.1. The asymmetry factor increased by 5.4 times with the geometric standard deviation varying from 1.2 to 3.0. The radiation transmission is very sensitive to the change in size distribution; other factors are not as significant. To determine the aerosol direct radiative forcing (ADRF), the aerosol optical depth (AOD) values at the three operational wavelengths (415, 500 and 673 nm) were determined at a regionally representative site, namely, Mt. Gibbs (35.78 deg N, 82.29 deg W, elevation 2006 m) in Mt. Mitchell State Park, NC, and a site located in an adjacent valley (Black Mountain, 35.66 deg N, 82.38 deg W, elevation 951 m) in the southeastern US. The two sites are separated horizontally by 10 km and vertically by 1 km. It was found that the representative total AOD values at 500 nm at the valley site for highly polluted (HP), marine (M) and continental (C) air masses were 0.68 +/- 0.33, 0.29 +/- 0.19 and 0.10 +/- 0.04, respectively. A search-graph method was used to retrieve the columnar size distribution (number concentration N, effective radius reff and geometric standard deviation=?g) from the optical depth observations at three operational wavelengths. The ground albedo, single scattering albedo and imaginary part of the refractive index were calculated using a

  14. Elemental concentration in normal skin and fibroepithelial polip lesions by synchrotron radiation total reflection X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Soares, Julio C.A.C.R.; Canellas, Catarine G.L.; Lopes, Ricardo T.; Anjos, Marcelino J.

    2011-01-01

    In this work, the concentrations of trace elements were measured in acrochordon, a skin lesion also known as skin tag or fibroepithelial polyp, as well as in normal skin from the same patient. The samples were analysed by Synchrotron Radiation Total Reflection X- ray Fluorescence (SRTXRF) in the Synchrotron Light National Laboratory (LNLS) in Campinas/Sao Paulo-Brazil. The collection of lesion and healthy skin samples, including papillary dermis and epidermis, has involved 17 patients. It was evaluated the presence of P, S, Cl, K, Ca, Cr, Mn, Fe, Cu, Zn, Br and Rb in the paired samples, which were compared, and significant differences were found in some of them. (author)

  15. Direct radiative effects induced by intense desert dust outbreaks over the broader Mediterranean basin

    Science.gov (United States)

    Gkikas, Antonis; Obiso, Vincenzo; Vendrell, Lluis; Basart, Sara; Jorba, Oriol; Pérez Garcia-Pando, Carlos; Hatzianastassiou, Nikos; Gassó, Santiago; Baldasano, Jose Maria

    2016-04-01

    Throughout the year, under favorable conditions, massive loads of mineral particles originating in the northern African and Middle East deserts are transported over the Mediterranean basin. Due to their composition and size, dust aerosols perturb the Earth-Atmosphere system's energy budget interacting directly with the shortwave (SW) and longwave (LW) radiation. The present study aims to compute the Mediterranean dust outbreaks' direct radiative effects (DREs) as well as to assess the effect of including dust DREs in numerical simulations of a regional model. To this aim, 20 intense dust outbreaks have been selected based on their spatial coverage and intensity. Their identification, over the period 2000-2013, has been achieved through an objective and dynamic algorithm which utilizes as inputs daily satellite retrievals derived by the MODIS-Terra, EP-TOMS and OMI-Aura sensors. For each outbreak, two simulations of the NMMB/BSC-Dust model were made for a forecast period of 84 hours, with the model initialized at 00 UTC of the day when the dust outbreak was ignited, activating (RADON) and deactivating (RADOFF) dust-radiation interactions. The simulation domain covers the northern Africa, the Middle East and Europe at 0.25° x 0.25° horizontal resolution, for 40 hybrid sigma pressure levels up to 50 hPa. The instantaneous and regional DREs have been calculated at the top of the atmosphere (TOA), into the atmosphere (ATMAB), and at surface, for the downwelling (SURF) and the absorbed (NETSURF) radiation, for the SW, LW and NET (SW+LW) radiation. The interaction between dust aerosols and NET radiation, locally leads to an atmospheric warming (DREATMAB) by up to 150 Wm-2, a surface cooling (DRENETSURF) by up to 250 Wm-2 and a reduction of the downwelling radiation at the surface (DRESURF) by up to 300 Wm-2. At TOA, DREs are mainly negative (down to -150 Wm-2) indicating a cooling of the Earth-Atmosphere system, although positive values (up to 50 Wm-2) are encountered

  16. TH-AB-201-05: Determining the Direction Distribution of the Primary Radiation for a Cyberknife-M6

    International Nuclear Information System (INIS)

    Henzen, D; Schmidhalter, D; Volken, W; Mackeprang, P-H; Malthaner, M; K Fix, M; Manser, P; C Zanella, C

    2016-01-01

    Purpose: Radiation protection regulatory differentiates between primary and scatter radiation. Whereas for conventional clinical linear accelerators the solid angle for primary radiation is planar, the Cyberknife (Accuray Inc., Sunnyvale, CA) may point its beam in all spatial directions. In order to be able to judge on radiation protection calculations for a Cyberknife-M6 vault, the direction distribution for delivered plans was evaluated based on clinical experiences. Methods: The log-files of 121 delivered patient treatment plans were exported, divided into cranial and extra-cranial treatments and the delivered monitor units (MU) together with the corresponding beam directions were analyzed. This MU-weighted spatial distribution was then projected to a 9.5 × 5.9 × 3.9 m 3 vault, generating an “intensity map” using a binning of 50 × 50 cm 2 . The factor of direction (FOD) is reported as a fraction of the total applied MUs to the walls, ceiling and floor in the perspective of a patient lying in head-first-supine position on the couch. In this study, the term intFOD refers to the integral FOD and maxFOD refers to the maximal FOD for a single bin. Results: For all kind of treatments and collimators, intFOD and maxFOD for the wall behind the patient’s head is 0.0. The intFOD for the floor varies between 0.65 and 0.74. For the ceiling, maxFOD is 0.002 and 0.0 for cranial and extra-cranial cases, respectively. The intFOD for the wall at the patient’s feet, is 0.094 for cranial and 0.005 for extra-cranial cases. There is nearly no difference between the maxFOD of the right and left wall for cranial cases, whereas for extra-cranial cases these numbers differ by a factor of 1.75. Conclusion: The varying FODs for the Cyberknife were quantified based on delivered treatment plans. These findings are helpful regarding the design of Cyberknife vaults.

  17. Study on recovering directly the commercial cerium oxide and total of residue rare earths from Dongpao bastnasite concentrate

    International Nuclear Information System (INIS)

    Nguyen Trong Hung; Nguyen Thanh Chung; Luu Xuan Dinh

    2003-01-01

    A technology for decomposition roasting and sequential leaching processes of Dong Pao bastnasite concentrate to recover directly commercial cerium oxide and total of residue rare earth elements from the leaching solution of the roasted product have been investigated. The bastnasite concentrate is initially roasted at temperature range of 600 - 650 degC and for time of 4 hrs in order to decompose and convert the hardly soluble carbonate forms of ore into easily soluble oxide. The roasted solid is then leached with sulfuric acid solution of 6N at 60 degC for 4 hrs to convert rare earths in oxide and fluoride form into rare earth sulfate. The recovery yield of rare earths of these stages is more than 95%. The attention has especially been paid on recovering directly the commercial cerium oxide and total of residue rare earth element from the above leaching solution. Complex ions of CeSO 4 2+ , Ce(SO 4 ) 2 , Ce(SO 4 ) 3 2- and Ce(SO 4 ) 4 4- exist in aqueous solution of cerium (IV) sulfate. Based on the property, the method of ion - sieve with DOWEX cation resin column has been applied to estimating separation of the ceric complex anions from Ln(III). The survey showed that most of the ceric complex anions are separated from total of residue rare earths. The latter which are absorbed in the cation column are recovered by elution of HCl of 4N. The recovery yield of cerium can only be reached 20% but the purity of that is very high, can be reached 99.6%. About 5 kg of CeO 2 of high grade and 5 kg of TREO of commercial specification have been produced. (author)

  18. A multilayer physically based snowpack model simulating direct and indirect radiative impacts of light-absorbing impurities in snow

    Science.gov (United States)

    Tuzet, Francois; Dumont, Marie; Lafaysse, Matthieu; Picard, Ghislain; Arnaud, Laurent; Voisin, Didier; Lejeune, Yves; Charrois, Luc; Nabat, Pierre; Morin, Samuel

    2017-11-01

    Light-absorbing impurities (LAIs) decrease snow albedo, increasing the amount of solar energy absorbed by the snowpack. Its most intuitive and direct impact is to accelerate snowmelt. Enhanced energy absorption in snow also modifies snow metamorphism, which can indirectly drive further variations of snow albedo in the near-infrared part of the solar spectrum because of the evolution of the near-surface snow microstructure. New capabilities have been implemented in the detailed snowpack model SURFEX/ISBA-Crocus (referred to as Crocus) to account for impurities' deposition and evolution within the snowpack and their direct and indirect impacts. Once deposited, the model computes impurities' mass evolution until snow melts out, accounting for scavenging by meltwater. Taking advantage of the recent inclusion of the spectral radiative transfer model TARTES (Two-stream Analytical Radiative TransfEr in Snow model) in Crocus, the model explicitly represents the radiative impacts of light-absorbing impurities in snow. The model was evaluated at the Col de Porte experimental site (French Alps) during the 2013-2014 snow season against in situ standard snow measurements and spectral albedo measurements. In situ meteorological measurements were used to drive the snowpack model, except for aerosol deposition fluxes. Black carbon (BC) and dust deposition fluxes used to drive the model were extracted from simulations of the atmospheric model ALADIN-Climate. The model simulates snowpack evolution reasonably, providing similar performances to our reference Crocus version in terms of snow depth, snow water equivalent (SWE), near-surface specific surface area (SSA) and shortwave albedo. Since the reference empirical albedo scheme was calibrated at the Col de Porte, improvements were not expected to be significant in this study. We show that the deposition fluxes from the ALADIN-Climate model provide a reasonable estimate of the amount of light-absorbing impurities deposited on the

  19. Investigation on atmospheric transmittance based on spectral and total direct insolation data; Nissha data ni motozuku taiki tokaritsu no kento

    Energy Technology Data Exchange (ETDEWEB)

    Baba, H; Kanayama, K; Endo, N [Kitami Institute of Technology, Hokkaido (Japan)

    1997-11-25

    Spectral insolation values measured at Kitami since 1994 by using a multi-purpose spectral radiometer, and direct insolation data collected at seven locations are available. Based on these data, effects of sun`s altitude and atmospheric condition on atmospheric transmittance were discussed. Spectra of insolation received on the ground are subjected to scattering and absorption by gas and particulates, and show complex shapes while they transmit from the sun, reach the atmosphere of the earth and pass through the atmosphere. The Bird`s model is shown. Impact of the sun`s altitude on the spectra of insolation directly reaching the ground is small if the altitude is higher than 45 degrees. The impact grows suddenly large when it is lower than 30 degrees. Atmospheric turbidity (caused by aerosols generated by volcanic eruption or exhaust gases) affects the spectral transmittance over the whole wavelength region. Amount of steam in the atmosphere has a strong effect on the spectral transmittance in the steam absorption band. Total transmittance of the atmosphere was sought based on the measurement data of insolation directly reaching the ground at eight locations from Kitami to Shiono-misaki. The transmittance at each location is in a range from 0.75 to 0.83 showing close proximity. These data agreed well also with the average transmittance surveyed by the Meteorological Agency. 7 refs., 8 figs.

  20. Hematological reaction of farm animals to total ionizing radiation (survey of literature)

    Energy Technology Data Exchange (ETDEWEB)

    Kruglikov, B.P.

    1984-06-01

    Hematological changes in the peripheral blood of farm animals after x-ray or gamma-irradiation are described and discussed on the basis of material from the literature. Aplastic anemia was found in all animals studied 2-3 weeks after irradiation. Complete restoration of erythrocyte concentration did not occur for a very long time after irradiation. The leukocyte count dropped markedly after irradiation. Maximum thrombocytopenia correlated with the height of the hemorrhagic syndrome. All formed elements of the blood changed quantitatively after irradiation and all changes were directly related to the irradiation dose. Thrombocytopenia followed leukocytopenia in the animals and the lowest concentration of platelets in the blood was noted before animals died. Data presented in the literature are unsuitable for quantification of results by mathematical processing. 61 references.

  1. Relative effect of radiation dose rate on hemopoietic and nonhemopoietic lethality of total-body irradiation

    International Nuclear Information System (INIS)

    Peters, L.J.; McNeill, J.; Karolis, C.; Thames, H.D. Jr.; Travis, E.L.

    1986-01-01

    Experiments were undertaken to determine the influence of dose rate on the toxicity of total-body irrdiation (TBI) with and without syngeneic bone-marrow rescue in mice. The results showed a much greater dose-rate dependence for death from nonhemopoietic toxicity than from bone-marrow ablation, with the ratio of LD 50 's increasing from 1.73 at 25 cGy/min to 2.80 at 1 cGy/min. At the higher dose rates, dose-limiting nonhemopoietic toxicity resulted from late organ injury, affecting the lungs, kidneys, and liver. At 1 cGy/min the major dose-limiting nonhemopoietic toxicity was acute gastrointestinal injury. The implications of these results in the context of TBI in preparation for bone-marrow transplantation are discussed. 15 refs., 4 figs

  2. Direct Radiative Effect of Mineral Dust on the Middle East and North Africa Climate

    KAUST Repository

    Bangalath, Hamza Kunhu

    2016-11-01

    Dust-climate interaction over the Middle East and North Africa (MENA) has long been studied, as it is the "dustiest" region on earth. However, the quantitative and qualitative understanding of the role of dust direct radiative effect on MENA climate is still rudimentary. The present dissertation investigates dust direct radiative effect on MENA climate during summer with a special emphasis on the sensitivity of climate response to dust shortwave absorption, which is one of the most uncertain components of dust direct radiative effect. Simulations are conducted with and without dust radiative effect, to differentiate the effect of dust on climate. To elucidate the sensitivity of climate response to dust shortwave absorption, simulations with dust assume three different cases of dust shortwave absorption, representing dust as a very efficient, standard and inefficient shortwave absorber. The non-uniformly distributed dust perturb circulations at various scales. Therefore, the present study takes advantage of the high spatial resolution capabilities of an Atmospheric General Circulation Model (AGCM), High Resolution Atmospheric Model (HiRAM), which incorporates global and regional circulations. AMIP-style global high-resolution simulations are conducted at a spatial resolution of 25 km. A significant response in the strength and position of the local Hadley circulation is predicted in response to meridionally asymmetric distribution of dust and the corresponding radiative effects. Significant responses are also found in regional circulation features such as African Easterly Jet and West African Monsoon circulation. Consistent with these dynamic responses at various scales, the tropical rainbelt across MENA strengthens and shifts northward. Similarly, the temperature under rainbelt cools and that over subtropical deserts warms. Inter-comparison of various dust shortwave absorption cases shows that the response of the MENA tropical rainbelt is extremely sensitive to the

  3. Clear-Sky Probability for the August 21, 2017, Total Solar Eclipse Using the NREL National Solar Radiation Database

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Roberts, Billy J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kutchenreiter, Mark C [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sengupta, Manajit [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Wilcox, Steve [Solar Resource Solutions, LLC, Lakewood, CO (United States); Stoffel, Tom [Solar Resource Solutions, LLC, Lakewood, CO (United States)

    2017-07-21

    The National Renewable Energy Laboratory (NREL) and collaborators have created a clear-sky probability analysis to help guide viewers of the August 21, 2017, total solar eclipse, the first continent-spanning eclipse in nearly 100 years in the United States. Using cloud and solar data from NREL's National Solar Radiation Database (NSRDB), the analysis provides cloudless sky probabilities specific to the date and time of the eclipse. Although this paper is not intended to be an eclipse weather forecast, the detailed maps can help guide eclipse enthusiasts to likely optimal viewing locations. Additionally, high-resolution data are presented for the centerline of the path of totality, representing the likelihood for cloudless skies and atmospheric clarity. The NSRDB provides industry, academia, and other stakeholders with high-resolution solar irradiance data to support feasibility analyses for photovoltaic and concentrating solar power generation projects.

  4. A Total-Evidence Approach to Dating with Fossils, Applied to the Early Radiation of the Hymenoptera

    Science.gov (United States)

    Ronquist, Fredrik; Klopfstein, Seraina; Vilhelmsen, Lars; Schulmeister, Susanne; Murray, Debra L.; Rasnitsyn, Alexandr P.

    2012-01-01

    Abstract Phylogenies are usually dated by calibrating interior nodes against the fossil record. This relies on indirect methods that, in the worst case, misrepresent the fossil information. Here, we contrast such node dating with an approach that includes fossils along with the extant taxa in a Bayesian total-evidence analysis. As a test case, we focus on the early radiation of the Hymenoptera, mostly documented by poorly preserved impression fossils that are difficult to place phylogenetically. Specifically, we compare node dating using nine calibration points derived from the fossil record with total-evidence dating based on 343 morphological characters scored for 45 fossil (4--20 complete) and 68 extant taxa. In both cases we use molecular data from seven markers (∼5 kb) for the extant taxa. Because it is difficult to model speciation, extinction, sampling, and fossil preservation realistically, we develop a simple uniform prior for clock trees with fossils, and we use relaxed clock models to accommodate rate variation across the tree. Despite considerable uncertainty in the placement of most fossils, we find that they contribute significantly to the estimation of divergence times in the total-evidence analysis. In particular, the posterior distributions on divergence times are less sensitive to prior assumptions and tend to be more precise than in node dating. The total-evidence analysis also shows that four of the seven Hymenoptera calibration points used in node dating are likely to be based on erroneous or doubtful assumptions about the fossil placement. With respect to the early radiation of Hymenoptera, our results suggest that the crown group dates back to the Carboniferous, ∼309 Ma (95% interval: 291--347 Ma), and diversified into major extant lineages much earlier than previously thought, well before the Triassic. [Bayesian inference; fossil dating; morphological evolution; relaxed clock; statistical phylogenetics.] PMID:22723471

  5. CALIPSO-Inferred Aerosol Direct Radiative Effects: Bias Estimates Using Ground-Based Raman Lidars

    Science.gov (United States)

    Thorsen, Tyler; Fu, Qiang

    2016-01-01

    Observational constraints on the change in the radiative energy budget caused by the presence of aerosols, i.e. the aerosol direct radiative effect (DRE), have recently been made using observations from the Cloud- Aerosol Lidar and Infrared Pathfinder Satellite (CALIPSO). CALIPSO observations have the potential to provide improved global estimates of aerosol DRE compared to passive sensor-derived estimates due to CALIPSO's ability to perform vertically-resolved aerosol retrievals over all surface types and over cloud. In this study we estimate the uncertainties in CALIPSO-inferred aerosol DRE using multiple years of observations from the Atmospheric Radiation Measurement (ARM) program's Raman lidars (RL) at midlatitude and tropical sites. Examined are assumptions about the ratio of extinction-to-backscatter (i.e. the lidar ratio) made by the CALIPSO retrievals, which are needed to retrieve the aerosol extinction profile. The lidar ratio is shown to introduce minimal error in the mean aerosol DRE at the top-of-atmosphere and surface. It is also shown that CALIPSO is unable to detect all radiatively-significant aerosol, resulting in an underestimate in the magnitude of the aerosol DRE by 30-50%. Therefore, global estimates of the aerosol DRE inferred from CALIPSO observations are likely too weak.

  6. The chemical basis of DNA damage by the direct pathway of ionizing radiation

    International Nuclear Information System (INIS)

    Sharma, Kiran Kumar K.

    2013-01-01

    Free radicals in living system has been implicated as playing a major role in the etiology of variety of diseases. The mechanism of free radicals in vivo involves predominantly the reaction with the DNA, producing different types of damage to the DNA. These lesions induced to the DNA could lead to mutation and even cell death. Radiolysis techniques, which uses ionizing radiation has proven to be one of the most advanced and excellent tool for studying the free radical reaction mechanisms as it can produce a host of well characterized free radicals. The effects of ionizing radiation on DNA have been studied for many years. Ionizing radiation interacts with DNA in vivo by two pathways, direct and indirect. The indirect accounts for 50-60% while the direct effect accounts for 40-50%. The chemical mechanism of the former reaction arising mainly from the reactive species produced by radiolysis of water has been extensively studied, however with respect to the later pathway, which creates holes and electrons to the DNA molecule using DNA films and crystals is an active area of research as both the pathways plays important roles in DNA damage in vivo particularly in chromosomal DNA which are tightly bound with histones and compartmentalized

  7. Accurate Models for Evaluating the Direct Conducted and Radiated Emissions from Integrated Circuits

    Directory of Open Access Journals (Sweden)

    Domenico Capriglione

    2018-03-01

    Full Text Available This paper deals with the electromagnetic compatibility (EMC issues related to the direct and radiated emissions from a high-speed integrated circuits (ICs. These emissions are evaluated here by means of circuital and electromagnetic models. As for the conducted emission, an equivalent circuit model is derived to describe the IC and the effect of its loads (package, printed circuit board, decaps, etc., based on the Integrated Circuit Emission Model template (ICEM. As for the radiated emission, an electromagnetic model is proposed, based on the superposition of the fields generated in the far field region by the loop currents flowing into the IC and the package pins. A custom experimental setup is designed for validating the models. Specifically, for the radiated emission measurement, a custom test board is designed and realized, able to highlight the contribution of the direct emission from the IC, usually hidden by the indirect emission coming from the printed circuit board. Measurements of the package currents and of the far-field emitted fields are carried out, providing a satisfactory agreement with the model predictions.

  8. Evaluation of Three Parametric Models for Estimating Directional Thermal Radiation from Simulation, Airborne, and Satellite Data

    Directory of Open Access Journals (Sweden)

    Xiangyang Liu

    2018-03-01

    Full Text Available An appropriate model to correct thermal radiation anisotropy is important for the wide applications of land surface temperature (LST. This paper evaluated the performance of three published directional thermal radiation models—the Roujean–Lagouarde (RL model, the Bidirectional Reflectance Distribution Function (BRDF model, and the Vinnikov model—at canopy and pixel scale using simulation, airborne, and satellite data. The results at canopy scale showed that (1 the three models could describe directional anisotropy well and the Vinnikov model performed the best, especially for erectophile canopy or low leaf area index (LAI; (2 the three models reached the highest fitting accuracy when the LAI varied from 1 to 2; and (3 the capabilities of the three models were all restricted by the hotspot effect, plant height, plant spacing, and three-dimensional structure. The analysis at pixel scale indicated a consistent result that the three models presented a stable effect both on verification and validation, but the Vinnikov model had the best ability in the erectophile canopy (savannas and grassland and low LAI (barren or sparsely vegetated areas. Therefore, the Vinnikov model was calibrated for different land cover types to instruct the angular correction of LST. Validation with the Surface Radiation Budget Network (SURFRAD-measured LST demonstrated that the root mean square (RMSE of the Moderate Resolution Imaging Spectroradiometer (MODIS LST product could be decreased by 0.89 K after angular correction. In addition, the corrected LST showed better spatial uniformity and higher angular correlation.

  9. Ionizing Radiation Effects on the Noise of 65 nm CMOS Transistors for Pixel Sensor Readout at Extreme Total Dose Levels

    CERN Document Server

    Re, V.; Manghisoni, M.; Riceputi, E.; Traversi, G.; Ratti, L.

    2018-01-01

    This paper is focused on the study of the noise performance of 65 nm CMOS transistors at extremely high total ionizing dose (TID) levels of the order of several hundreds of Mrad(SiO2). Noise measurements are reported and discussed, analyzing radiation effects on 1/ f noise and channel thermal noise. In nMOSFETs, up to 10 Mrad(SiO2), the experimental behavior is consistent with a damage mechanism mainly associ- ated with lateral isolation oxides, and can be modeled by parasitic transistors turning on after irradiation and contributing to the total noise of the device. At very high dose, these parasitic transistors tend to be turned off by negative charge accumulating in interface states and compensating radiation-induced positive charge building up inside thick isolation oxides. Effects associated with ionization and hydrogen transport in spacer oxides may become dominant at 600 Mrad(SiO2) and may explain the observed noise behavior at extremely high TID. The results of this analysis provide an understanding o...

  10. Local total and radiative heat-transfer coefficients during the heat treatment of a workpiece in a fluidised bed

    International Nuclear Information System (INIS)

    Gao, W.M.; Kong, L.X.; Hodgson, P.D.

    2006-01-01

    The heat-transfer coefficients around a workpiece immersed in an electrically heated heat treatment fluidised bed were studied. A suspension probe designed to simulate a workpiece of complex geometry was developed to measure local total and radiative heat-transfer coefficients at a high bed temperature. The probe consisted of an energy-storage region separated by insulation from the fluidised bed, except for the measuring surface, and a multi-thermocouple measurement system. Experiments in the fluidised bed were performed for a fluidising medium of 120-mesh alumina, a wide temperature range of 110-1050 deg. C and a fluidising number range of 1.18-4.24. It was found that the workpiece surface temperature has a more significant effect on heat transfer than the bed temperature. The total heat-transfer coefficient at the upper surface of the workpiece sharply decreased at the start of heating, and then steadily increased as heating progressed, while a sharp decrease became a rapid increase and then a slow increase for the radiative heat-transfer coefficient. A great difference in the heat-transfer coefficients around the workpiece was observed

  11. Use of 60Co gamma radiation in increased levels of total polyphenol extracts of bark of Schinus terebinthifolius Raddi

    International Nuclear Information System (INIS)

    Santos, Gustavo H.F.; Silva, Edvane B.; Silva, Hianna A.M.F.; Amorin, Elba L.C.; Peixoto, Tadeu J.S.; Yara, Ricardo; Lima, Claudia S.A.

    2013-01-01

    Schinus terebinthifolius Raddi (Anacardiaceae) is well known as sources of phenolic compounds. Known as mastic pepper, red pepper tree is a plant native to midsize coast of Brazil. Some of its structures have proven antibacterial, anti-inflammatory, antifungal and healing. The aim of this study was to evaluate the difference in the phenol contents of crude extracts that were measured after irradiating the barks of S. terebinthifolius using gamma radiation from 60 Co. The crude extract were divided into a control group and eight experimental groups, which were separated based on the doses of gamma radiation to which they were exposed: 2.5, 5.0, 7.5, 10.0, 12.5, 15.0, 20.0 and 50.0 kGy (Assays were performed in triplicate). The results allow observe that gamma radiation promoted in extracts of bark of S. terebinthifolius, many percents increase (p> 0.05) of total polyphenol content between 2.5 kGy (41.93%) and 50.0 kGy (44.52%) compared to 0 kGy (30.07%), with the same gradual to 10.0 kGy, and reaching peak maximum at 10.0 kGy (68.44%). However, the study puts the process of gamma radiation from 60 Co as an alternative significant increase in the percentage of some natural substances of plant material, and subsequently contribute to the augmentation of various therapeutic applications to which they are assigned. (author)

  12. Use of {sup 60}Co gamma radiation in increased levels of total polyphenol extracts of bark of Schinus terebinthifolius Raddi

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Gustavo H.F.; Silva, Edvane B.; Silva, Hianna A.M.F.; Amorin, Elba L.C.; Peixoto, Tadeu J.S.; Yara, Ricardo; Lima, Claudia S.A., E-mail: santosghf@hotmail.com, E-mail: edvborges@yahoo.com, E-mail: amdemelo@hotmail.com, E-mail: claudia.salima@gmail.com, E-mail: ricardo.yara@gmail.com, E-mail: tadeu1903@yahoo.com.br, E-mail: elba@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2013-07-01

    Schinus terebinthifolius Raddi (Anacardiaceae) is well known as sources of phenolic compounds. Known as mastic pepper, red pepper tree is a plant native to midsize coast of Brazil. Some of its structures have proven antibacterial, anti-inflammatory, antifungal and healing. The aim of this study was to evaluate the difference in the phenol contents of crude extracts that were measured after irradiating the barks of S. terebinthifolius using gamma radiation from {sup 60}Co. The crude extract were divided into a control group and eight experimental groups, which were separated based on the doses of gamma radiation to which they were exposed: 2.5, 5.0, 7.5, 10.0, 12.5, 15.0, 20.0 and 50.0 kGy (Assays were performed in triplicate). The results allow observe that gamma radiation promoted in extracts of bark of S. terebinthifolius, many percents increase (p> 0.05) of total polyphenol content between 2.5 kGy (41.93%) and 50.0 kGy (44.52%) compared to 0 kGy (30.07%), with the same gradual to 10.0 kGy, and reaching peak maximum at 10.0 kGy (68.44%). However, the study puts the process of gamma radiation from {sup 60}Co as an alternative significant increase in the percentage of some natural substances of plant material, and subsequently contribute to the augmentation of various therapeutic applications to which they are assigned. (author)

  13. Radiation protection cabin for catheter-directed liver interventions: operator dose assessment

    International Nuclear Information System (INIS)

    Maleux, Geert; Bosmans, Hilde; Bergans, Niki; Bogaerts, Ria

    2016-01-01

    The number and complexity of interventional radiological procedures and in particular catheter-directed liver interventions have increased substantially. The current study investigates the reduction of personal doses when using a dedicated radiation protection cabin (RPC) for these procedures. Operator and assistant doses were assessed for 3 series of 20 chemo-infusion/chemoembolisation interventions, including an equal number of procedures with and without RPC. Whole body doses, finger doses and doses at the level of knees and eyes were evaluated with different types of TLD-100 Harshaw dosemeters. Dosemeters were also attached on the three walls of the RPC. The operator doses were significantly reduced by the RPC, but also without RPC, the doses appear to be limited as a result of thorough optimisation with existing radiation protection tools. The added value of the RPC should thus be determined by the outcome of balancing dose reduction and other aspects such as ergonomic benefits. (authors)

  14. A theoretical study on directivity control of multiple-loudspeaker system with a quadrupole radiation pattern in low frequency range

    Science.gov (United States)

    Irwansyah, Kuse, Naoyuki; Usagawa, Tsuyoshi

    2017-08-01

    Directivity pattern of an ordinary loudspeaker becomes more directive at higher frequencies. However, because a single loudspeaker tends to radiate uniformly in all directions at low frequencies, reverberation from surrounding building walls may affect speech intelligibility when installing a multiple-loudspeaker system at crossroads. As an alternative, a sharply directive sound source is recommended to be used, but in many cases the directivity of an ordinary loudspeaker is less sharp at lower frequencies. Therefore, in order to overcome such a limitation, this paper discusses the possibility of using four loudspeakers under active control to realize a quadrupole radiation pattern in low frequency range. In this study, the radiation pattern of a primary loudspeaker and three secondary loudspeakers has been modelled. By placing the loudspeakers close together in the direction of 0°, 90°, 180°, and 270°, it was theoretically demonstrated that a quadrupole radiation pattern can be shaped in the target frequency range up to 600 Hz by simply controlling the directivity in three of four directions which are 45°, 135°, 225°, and 315°. Although, the radiation pattern model is far from realistic configurations and conditions, it is possible to realize a quadrupole radiation pattern in the low frequency range.

  15. Template-Directed Instrumentation Reduces Cost and Improves Efficiency for Total Knee Arthroplasty: An Economic Decision Analysis and Pilot Study.

    Science.gov (United States)

    McLawhorn, Alexander S; Carroll, Kaitlin M; Blevins, Jason L; DeNegre, Scott T; Mayman, David J; Jerabek, Seth A

    2015-10-01

    Template-directed instrumentation (TDI) for total knee arthroplasty (TKA) may streamline operating room (OR) workflow and reduce costs by preselecting implants and minimizing instrument tray burden. A decision model simulated the economics of TDI. Sensitivity analyses determined thresholds for model variables to ensure TDI success. A clinical pilot was reviewed. The accuracy of preoperative templates was validated, and 20 consecutive primary TKAs were performed using TDI. The model determined that preoperative component size estimation should be accurate to ±1 implant size for 50% of TKAs to implement TDI. The pilot showed that preoperative template accuracy exceeded 97%. There were statistically significant improvements in OR turnover time and in-room time for TDI compared to an historical cohort of TKAs. TDI reduces costs and improves OR efficiency. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Mechanisms of poliovirus inactivation by the direct and indirect effects of ionizing radiation

    International Nuclear Information System (INIS)

    Ward, R.L.

    1980-01-01

    This study was designed to measure the effects of ionizing radiation on poliovirus particles when given under conditions where either direct (in broth) or indirect (in water) effects were predominant. Under direct conditions, inactivation of poliovirus was found to be due primarily to RNA damage, although capsid damage could account for about one-third of the viral inactivation. RNA damage did not appear to be due to strand breakage and therefore was probably caused primarily by base damage or crosslink formation. Capsid damage under direct irradiation conditions did not result in significant alterations of either the sedimentation coefficients or the isoelectric points of the poliovirus particles or detectable modification of the sizes of the viral proteins. It did, however, cause loss of availability to bind to host cells. Under indirect conditions no more than 25% of viral inactivation appeared to be due to RNA damage. However, the sedimentation coefficients and isoelectric points of the viral particles were greatly altered, and their abilities to bind to cells were lost at about three-fourths the rate of loss of infectivity. Capsid damage in this case did result in changes in the sizes of capsid proteins. Therefore, the majority of the radiation inactivation under indirect conditions appeared to be due to protein damage

  17. Seeing the invisible: direct visualization of therapeutic radiation beams using air scintillation.

    Science.gov (United States)

    Fahimian, Benjamin; Ceballos, Andrew; Türkcan, Silvan; Kapp, Daniel S; Pratx, Guillem

    2014-01-01

    To assess whether air scintillation produced during standard radiation treatments can be visualized and used to monitor a beam in a nonperturbing manner. Air scintillation is caused by the excitation of nitrogen gas by ionizing radiation. This weak emission occurs predominantly in the 300-430 nm range. An electron-multiplication charge-coupled device camera, outfitted with an f/0.95 lens, was used to capture air scintillation produced by kilovoltage photon beams and megavoltage electron beams used in radiation therapy. The treatment rooms were prepared to block background light and a short-pass filter was utilized to block light above 440 nm. Air scintillation from an orthovoltage unit (50 kVp, 30 mA) was visualized with a relatively short exposure time (10 s) and showed an inverse falloff (r(2) = 0.89). Electron beams were also imaged. For a fixed exposure time (100 s), air scintillation was proportional to dose rate (r(2) = 0.9998). As energy increased, the divergence of the electron beam decreased and the penumbra improved. By irradiating a transparent phantom, the authors also showed that Cherenkov luminescence did not interfere with the detection of air scintillation. In a final illustration of the capabilities of this new technique, the authors visualized air scintillation produced during a total skin irradiation treatment. Air scintillation can be measured to monitor a radiation beam in an inexpensive and nonperturbing manner. This physical phenomenon could be useful for dosimetry of therapeutic radiation beams or for online detection of gross errors during fractionated treatments.

  18. Seeing the invisible: Direct visualization of therapeutic radiation beams using air scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Fahimian, Benjamin; Türkcan, Silvan; Kapp, Daniel S.; Pratx, Guillem, E-mail: pratx@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305 (United States); Ceballos, Andrew [Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States)

    2014-01-15

    Purpose: To assess whether air scintillation produced during standard radiation treatments can be visualized and used to monitor a beam in a nonperturbing manner. Methods: Air scintillation is caused by the excitation of nitrogen gas by ionizing radiation. This weak emission occurs predominantly in the 300–430 nm range. An electron-multiplication charge-coupled device camera, outfitted with an f/0.95 lens, was used to capture air scintillation produced by kilovoltage photon beams and megavoltage electron beams used in radiation therapy. The treatment rooms were prepared to block background light and a short-pass filter was utilized to block light above 440 nm. Results: Air scintillation from an orthovoltage unit (50 kVp, 30 mA) was visualized with a relatively short exposure time (10 s) and showed an inverse falloff (r{sup 2} = 0.89). Electron beams were also imaged. For a fixed exposure time (100 s), air scintillation was proportional to dose rate (r{sup 2} = 0.9998). As energy increased, the divergence of the electron beam decreased and the penumbra improved. By irradiating a transparent phantom, the authors also showed that Cherenkov luminescence did not interfere with the detection of air scintillation. In a final illustration of the capabilities of this new technique, the authors visualized air scintillation produced during a total skin irradiation treatment. Conclusions: Air scintillation can be measured to monitor a radiation beam in an inexpensive and nonperturbing manner. This physical phenomenon could be useful for dosimetry of therapeutic radiation beams or for online detection of gross errors during fractionated treatments.

  19. Potential sensitivity of photosynthesis and isoprene emission to direct radiative effects of atmospheric aerosol pollution

    Science.gov (United States)

    Strada, Susanna; Unger, Nadine

    2016-04-01

    A global Earth system model is applied to quantify the impacts of direct anthropogenic aerosol effective radiative forcing on gross primary productivity (GPP) and isoprene emission. The impacts of different pollution aerosol sources (anthropogenic, biomass burning, and non-biomass burning) are investigated by performing sensitivity experiments. The model framework includes all known light and meteorological responses of photosynthesis, but uses fixed canopy structures and phenology. On a global scale, our results show that global land carbon fluxes (GPP and isoprene emission) are not sensitive to pollution aerosols, even under a global decline in surface solar radiation (direct + diffuse) by ˜ 9 %. At a regional scale, GPP and isoprene emission show a robust but opposite sensitivity to pollution aerosols in regions where forested canopies dominate. In eastern North America and Eurasia, anthropogenic pollution aerosols (mainly from non-biomass burning sources) enhance GPP by +5-8 % on an annual average. In the northwestern Amazon Basin and central Africa, biomass burning aerosols increase GPP by +2-5 % on an annual average, with a peak in the northwestern Amazon Basin during the dry-fire season (+5-8 %). The prevailing mechanism varies across regions: light scattering dominates in eastern North America, while a reduction in direct radiation dominates in Europe and China. Aerosol-induced GPP productivity increases in the Amazon and central Africa include an additional positive feedback from reduced canopy temperatures in response to increases in canopy conductance. In Eurasia and northeastern China, anthropogenic pollution aerosols drive a decrease in isoprene emission of -2 to -12 % on an annual average. Future research needs to incorporate the indirect effects of aerosols and possible feedbacks from dynamic carbon allocation and phenology.

  20. A Direct Radiative Transfer Equation Solver for Path Loss Calculation of Underwater Optical Wireless Channels

    KAUST Repository

    Li, Changping

    2014-11-10

    In this report, we propose a fast numerical solution for the steady state radiative transfer equation in order to calculate the path loss due to light absorption and scattering in various type of underwater channels. In the proposed scheme, we apply a direct non-uniform method to discretize the angular space and an upwind type finite difference method to discretize the spatial space. A Gauss-Seidel iterative method is then applied to solve the fully discretized system of linear equations. The accuracy and efficiency of the proposed scheme is validated by Monte Carlo simulations.

  1. A Direct Radiative Transfer Equation Solver for Path Loss Calculation of Underwater Optical Wireless Channels

    KAUST Repository

    Li, Changping; Park, Ki-Hong; Alouini, Mohamed-Slim

    2014-01-01

    In this report, we propose a fast numerical solution for the steady state radiative transfer equation in order to calculate the path loss due to light absorption and scattering in various type of underwater channels. In the proposed scheme, we apply a direct non-uniform method to discretize the angular space and an upwind type finite difference method to discretize the spatial space. A Gauss-Seidel iterative method is then applied to solve the fully discretized system of linear equations. The accuracy and efficiency of the proposed scheme is validated by Monte Carlo simulations.

  2. Clinical evaluation of direct and photosensitized ultraviolet radiation damage to the lens

    International Nuclear Information System (INIS)

    Hockwin, O.; Lerman, S.

    1982-01-01

    We are reporting a new, objective, and quantitative method for monitoring age-related molecular changes in the human ocular lens in vivo, as expressed by increases in at least two (nontryptophan) fluorescence wavelengths. These fluorescence wavelengths appear to be caused by photochemically induced changes in the lens, and they reflect the ultraviolet (UV) filtering capacity of the patients' ocular lenses. These data correlate with previously reported in vitro lens fluorescence changes that are associated with the aging process. This method will also detect alterations in lenticular fluorescence caused by photosensitized as well as direct UV radiation damage

  3. Method of shaping of direction-characterization of sensitivity of ionizing radiation detection probe

    International Nuclear Information System (INIS)

    Czarnecki, J.; Jaszczuk, J.; Kruczyk, M.; Slapa, M.; Wroblewski, T.

    1986-01-01

    A method of shaping of direction-characterization of sensitivity of the ionizing radiation detection probe, especially equipped with small gamma detectors is described. Two detectors are placed coaxially in the bases of the cylindrical shield. One of them is uncovered in the highest degree and the second is not covered to a maximum. The signals from them are processed on the standarized sequences of electrical impulses (taking into account the heights and the widths of the amplitude). 2 figs., 1 tab. (A.S.)

  4. Long-range effects of direct-hit ultraviolet and particle radiation in oncogene activation

    International Nuclear Information System (INIS)

    Ladik, J.J.

    1990-01-01

    A simple statistical analysis shows that the oncogene-activation effect of chemical carcinogens cannot be explained if one takes into account only short-range effects. As one of the most probable solid state physical long-range effects, the generation at the site of carcinogen binding of travelling solitary waves, which can interfere with DNA-blocking protein interactions, is discussed. It has been shown that the direct hit carcinogenic effects on DNA by ultraviolet--or particle radiation can also be explained by the generation of solitary waves (in the latter case the first step is a collective plasma oscillation which decays to individual local excitations and ionizations)

  5. Experiment on direct nn scattering - The radiation-induced outgassing complication

    Energy Technology Data Exchange (ETDEWEB)

    Stephenson, S.L., E-mail: sstephen@gettysburg.edu [Gettysburg College, Gettysburg, PA 17325 (United States); Crawford, B.E. [Gettysburg College, Gettysburg, PA 17325 (United States); Furman, W.I.; Lychagin, E.V.; Muzichka, A.Yu.; Nekhaev, G.V.; Sharapov, E.I.; Shvetsov, V.N.; Strelkov, A.V. [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Levakov, B.G.; Lyzhin, A.E.; Chernukhin, Yu.I. [Russian Federal Nuclear Center - All Russian Research Institute of Technical Physics, P.O. Box 245, 456770 Snezhinsk (Russian Federation); Howell, C.R. [Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Mitchell, G.E. [North Carolina State University, Raleigh, NC 27695-8202 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Tornow, W. [Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Showalter-Bucher, R.A. [Northeastern University, Boston, MA 02115 (United States)

    2012-12-01

    The first direct neutron-neutron scattering experiment using the YAGUAR pulsed reactor has yielded initial results. They show a unforeseen significant thermal neutron background as a result of radiation-induced desorption within the scattering chamber. Thermal neutrons are mostly scattering not from other neutrons but instead from the desorbed gas molecules. Analysis of the obtained neutron time-of-flight spectra suggests neutron scattering from H{sub 2} molecules. The presented desorption model agrees with our experimental value of the desorption yield {eta}{sub {gamma}}=0.02 molecules/gamma. Possible techniques to reduce the effect of the desorption background are presented.

  6. The 1996 European Directive and radiation protection at CERN, or why 15 plus 4 is unequal to 19

    International Nuclear Information System (INIS)

    Hoefert, M.

    1997-04-01

    The recommendations of the 1996 EU Directive on radiation protection are compared with the practice at CERN as laid down in the 1996 Radiation Safety Manual which is largely based on the Swiss Radiation Protection Ordinance of 1994. The three topics discussed are individual dosimetry for persons exposed in the exercise of their profession, exemption values and clearance levels for radioactivity and committed effective dose coefficients, and reference levels for members of the public. (author)

  7. “Modeling Trends in Aerosol Direct Radiative Effects over the Northern Hemisphere using a Coupled Meteorology-Chemistry Model”

    Science.gov (United States)

    While aerosol radiative effects have been recognized as some of the largest sources of uncertainty among the forcers of climate change, the verification of the spatial and temporal variability of the magnitude and directionality of aerosol radiative forcing has remained challengi...

  8. NRC TLD Direct Radiation Monitoring Network. Volume 15, No. 4: Quarterly progress report, October--December 1995

    International Nuclear Information System (INIS)

    Struckmeyer, R.

    1996-03-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1995. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program

  9. NRC TLD Direct Radiation Monitoring Network. Volume 15, No. 4: Quarterly progress report, October--December 1995

    Energy Technology Data Exchange (ETDEWEB)

    Struckmeyer, R.

    1996-03-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1995. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program.

  10. Comparison of mechanisms for DNA strand break formation by the direct and indirect effect of radiation

    International Nuclear Information System (INIS)

    Schulte-Frohlinde, D.

    1986-01-01

    Irradiation of cells may lead to mutations, reproductive cell death and the disappearance of some or all cell activities. These effects, especially reproductive cell death, are believed to be the result of damage to DNA. Two kinds of formation of DNA damage are often distinguished, the so-called ''direct'' and the ''indirect'' effect of irradiation. The direct effect is due to ionization or electronic excitation of the DNA, and the indirect effect is caused by reactive species, in most cases free radicals, which are produced in the vicinity of the DNA. These radicals may be primary radicals produced by energy absorption in water, i.e., the solvated electron, the H-atom and the OH radical, or organic radicals produced from organic material other than DNA either by interaction with radiation or by reaction with the primary radicals generated from water. 36 refs., 2 figs., 2 tabs

  11. Measuring Air Temperature in Glazed Ventilated Facades in the Presence of Direct Solar Radiation

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Zanghirella, Fabio; Heiselberg, Per

    2007-01-01

    A distinctive element of buildings with a double glazed façade is naturally or mechanically driven flow in a ventilated cavity. Accurate air temperature measurements in the cavity are crucial to evaluate the dynamic performance of the façade, to predict and control its behavior as a significant...... part of the complete ventilation system. Assessment of necessary cooling/heating loads and of the whole building energy performance will then depend on the accuracy of measured air temperature. The presence of direct solar radiation is an essential element for the façade operation, but it can heavily...... affect measurements of air temperature and may lead to errors of high magnitude using bare thermocouples and even adopting shielding devices. Two different research groups, from Aalborg University and Politecnico di Torino, tested separately various techniques to shield thermocouples from direct...

  12. Engineering calculations in radiative heat transfer

    CERN Document Server

    Gray, W A; Hopkins, D W

    1974-01-01

    Engineering Calculations in Radiative Heat Transfer is a six-chapter book that first explains the basic principles of thermal radiation and direct radiative transfer. Total exchange of radiation within an enclosure containing an absorbing or non-absorbing medium is then described. Subsequent chapters detail the radiative heat transfer applications and measurement of radiation and temperature.

  13. Radiation therapy for angiosarcoma of the scalp. Treatment outcomes of total scalp irradiation with X-rays and electrons

    Energy Technology Data Exchange (ETDEWEB)

    Hata, Masaharu; Koike, Izumi; Kasuya, Takeo; Inoue, Tomio [Yokohama City University Graduate School of Medicine, Department of Radiology, Yokohama, Kanagawa (Japan); Wada, Hidefumi [Yokohama City University Graduate School of Medicine, Department of Dermatology, Yokohama, Kanagawa (Japan); Ogino, Ichiro [Yokohama City University Medical Center, Department of Radiation Oncology, Yokohama, Kanagawa (Japan); Omura, Motoko [Yokohama City University Graduate School of Medicine, Department of Radiology, Yokohama, Kanagawa (Japan); Shonankamakura General Hospital, Department of Radiation Oncology, Kamakura, Kanagawa (Japan); Tayama, Yoshibumi [Yokohama Minami Kyousai Hospital, Department of Radiology, Yokohama, Kanagawa (Japan); Odagiri, Kazumasa [Yokohama City University Graduate School of Medicine, Department of Radiology, Yokohama, Kanagawa (Japan); Yokohama Municipal Citizen' s Hospital, Department of Radiation Oncology, Yokohama, Kanagawa (Japan)

    2014-10-15

    Wide surgical excision is the standard treatment for angiosarcoma of the scalp, but many patients are inoperable. Therefore, we investigated the outcome of radiation therapy for angiosarcoma of the scalp. Seventeen patients with angiosarcoma of the scalp underwent radiation therapy with total scalp irradiation. Four patients had cervical lymph node metastases, but none had distant metastases. A median initial dose of 50 Gy in 25 fractions was delivered to the entire scalp. Subsequently, local radiation boost to the tumor sites achieved a median total dose of 70 Gy in 35 fractions. Fourteen of the 17 patients developed recurrences during the median follow-up period of 14 months after radiation therapy; 7 had recurrences in the scalp, including primary tumor progression in 2 patients and new disease in 5, and 12 patients developed distant metastases. The primary progression-free, scalp relapse-free, and distant metastasis-free rates were 86, 67, and 38 % at 1 year and 86, 38, and 16 % at 3 years, respectively. Thirteen patients died; the overall and cause-specific survival rates were both 73 % at 1 year and 23 and 44 % at 3 years, respectively. The median survival time was 16 months. There were no therapy-related toxicities ≥ grade 3. Total scalp irradiation is safe and effective for local tumor control, but a dose of ≤ 50 Gy in conventional fractions may be insufficient to eradicate microscopic tumors. For gross tumors, a total dose of 70 Gy, and > 70 Gy for tumors with deep invasion, is recommended. (orig.) [German] Umfangreiche chirurgische Exzision ist die Standardbehandlung fuer Angiosarkome der Kopfhaut, aber viele Patienten sind nicht operierbar. Daher haben wir die Ergebnisse einer Strahlenbehandlung fuer Angiosarkome der Kopfhaut untersucht. Insgesamt 17 Patienten mit Angiosarkom der Kopfhaut erhielten eine Strahlenbehandlung der gesamten Kopfhaut. Vier Patienten hatten zervikale Lymphknotenmetastasen, aber keine Fernmetastasen. Die gesamte Kopfhaut

  14. Fish samples as bioindicator of environmental quality: synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    International Nuclear Information System (INIS)

    Vives, Ana Elisa Sirito de; Moreira, Silvana; Brienza, Sandra Maria Boscolo; Zucchi, Orgheda Luiza Araujo Domingues; Nascimento Filho, Virgilio Franco do Centro de Energia Nuclear na Agricultura , Piracicaba, SP; Brazil)

    2005-01-01

    In this study fish were used as bioindicators of environmental contamination. The species were collected in Piracicaba River, Sao Paulo state, Brazil and the toxic elements concentrations were determined in muscle tissue and viscus (liver, intestine and stomach) by Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF). Were determined the elements Ti, Cr, Mn, Fe, Ni, Cu, Zn and Ba. The results were compared with values established by Brazilian Legislation for general food. The elements concentrations evidenced potential risk to human health and environmental quality alteration of the studied area. The measurements were realized at the 'Laboratorio Nacional de Luz Sincrotron' (LNLS) located in Campinas, Sao Paulo State, Brazil. (author)

  15. The Relative Effects of Manual Versus Automatic Exposure Control on Radiation Dose to Vital Organs in Total Hip Arthroplasty.

    Science.gov (United States)

    Harper, Katharine D; Li, Shidong; Jennings, Rachel; Amer, Kamil M; Haydel, Christopher; Ali, Sayed

    2018-01-01

    Technologic advances have reduced medical radiation exposure while maintaining image quality. The purpose of this study was to determine the effects of the presence of total hip arthroplasty implants, compared with native hips, on radiation exposure of the most radiosensitive organs when manual and automatic exposure control settings are used. Detection probes were placed at six locations (stomach, sigmoid colon, right pelvic wall, left pelvic wall, pubic symphysis, and anterior pubic skin) in a cadaver. Radiographs were obtained with the use of manual and automatic exposure control protocols, with exposures recorded. A total hip arthroplasty implant was placed in the cadaver, probe positioning was confirmed, and the radiographs were repeated, with exposure values recorded. The control probe placed at the stomach had values ranging from 0.00 mSv to 0.01 mSv in protocols with and without implants. With the manual protocol, exposures in the pelvis ranged from 0.36 mSv to 2.74 mSv in the native hip and from 0.33 mSv to 2.24 mSv after implant placement. The increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 0.818; left pelvic wall, 1.381; sigmoid colon, 1.550; right pelvic wall, 0.917; and anterior pubic skin, 1.015. With automatic exposure control, exposures in the pelvis ranged from 0.07 mSv to 0.89 mSv in the native hip and from 0.21 mSv to 1.15 mSv after implant placement. With automatic exposure control, the increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 1.292; left pelvic wall, 1.476; sigmoid colon, 2.182; right pelvic wall, 3.000; and anterior pubic skin, 1.378. The amount of radiation to which patients are exposed as a result of medical procedures or imaging, and whether exposure is associated with an increased risk of malignant transformation, are the subject of ongoing debate. We found that after insertion

  16. Fish samples as bioindicator of environmental quality: synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Brienza, Sandra Maria Boscolo [Universidade Metodista de Piracicaba (UNIMEP), SP (Brazil). Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: virgilio@cena.usp.br

    2005-07-01

    In this study fish were used as bioindicators of environmental contamination. The species were collected in Piracicaba River, Sao Paulo state, Brazil and the toxic elements concentrations were determined in muscle tissue and viscus (liver, intestine and stomach) by Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF). Were determined the elements Ti, Cr, Mn, Fe, Ni, Cu, Zn and Ba. The results were compared with values established by Brazilian Legislation for general food. The elements concentrations evidenced potential risk to human health and environmental quality alteration of the studied area. The measurements were realized at the 'Laboratorio Nacional de Luz Sincrotron' (LNLS) located in Campinas, Sao Paulo State, Brazil. (author)

  17. Correlation of the concentration of the carbon-associated radiation damage levels with the total carbon concentration in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Ferenczi, G.; Londos, C.A.; Pavelka, T.; Somogyi, M.; Mertens, A.

    1988-01-01

    The dominant carbon-related radiation damage center in silicon was studied in detail by deep level transient spectroscopy. Samples with different carbon and oxygen content were implanted with gradually increasing proton fluence. Two energetically closely spaced levels were revealed and tentative identities were assigned. One at E/sub T/+E/sub V/ = 0.344 eV (sigma/sub p/ = 1.1 x 10/sup -16/ cm/sup 2/) is assigned as the C+O/sub i/ complex, and that at E/sub T/+E/sub V/ = 0.370 eV (sigma/sub p/ = 8 x 10/sup -18/ cm/sup 2/) is assigned as the C/sub s/-Si/sub i/-C/sub s/ complex. It was shown that the concentration of these defects is correlated to the total concentration of carbon in the crystal.

  18. Direct radiative feedback due to biogenic secondary organic aerosol estimated from boreal forest site observations

    International Nuclear Information System (INIS)

    Lihavainen, Heikki; Asmi, Eija; Aaltonen, Veijo; Makkonen, Ulla; Kerminen, Veli-Matti

    2015-01-01

    We used more than five years of continuous aerosol measurements to estimate the direct radiative feedback parameter associated with the formation of biogenic secondary organic aerosol (BSOA) at a remote continental site at the edge of the boreal forest zone in Northern Finland. Our upper-limit estimate for this feedback parameter during the summer period (ambient temperatures above 10 °C) was −97 ± 66 mW m −2 K −1 (mean ± STD) when using measurements of the aerosol optical depth (f AOD ) and −63 ± 40 mW m −2 K −1 when using measurements of the ‘dry’ aerosol scattering coefficient at the ground level (f σ ). Here STD represents the variability in f caused by the observed variability in the quantities used to derive the value of f. Compared with our measurement site, the magnitude of the direct radiative feedback associated with BSOA is expected to be larger in warmer continental regions with more abundant biogenic emissions, and even larger in regions where biogenic emissions are mixed with anthropogenic pollution. (letter)

  19. Effects of preferential concentration on direct radiation transmission in a turbulent duct flow

    Science.gov (United States)

    Villafane, Laura; Banko, Andrew; Kim, Ji Hoon; Elkins, Chris; Eaton, John

    2017-11-01

    Inertial particles in turbulent flows preferentially concentrate, giving rise to spatial and temporal fluctuations of particle number density that affect radiation transmission through the medium. Positive particle correlations enhance direct transmission when compared to the exponential attenuation predicted by the Beer's Law for randomly distributed particles. In the context of a particle based solar receiver, this work studies the effects of preferential concentration and optical depth on direct transmission through a particle laden turbulent duct flow. Time resolved measurements of transmission through the mixture were performed for various particle loadings and Reynolds numbers, thus varying particle correlation lengths, optical depth and concentration fluctuations. These measurements were made using a photodiode to record the transmission of a collimated laser beam along the wall bisector of the duct. A synchronized high-speed camera provided particle positions along most of the beam path. Average and fluctuating radiation transmission results are compared to predictions derived from the imaged number density fields and to simplified analytical models. Simplified models are able to capture the correct trends with varying loading and preferential concentration. This work is funded by the Department of Energy's National Nuclear Security Administration, Grant #DE-NA0002373-1.

  20. Source attribution of black carbon and its direct radiative forcing in China

    International Nuclear Information System (INIS)

    Yang, Yang; Wang, Hailong; Ma, Po-Lun; Rasch, Philip J.; Smith, Steven J.

    2017-01-01

    The source attributions for mass concentration, haze formation, transport and direct radiative forcing of black carbon (BC) in various regions of China are quantified in this study using the Community Earth System Model (CESM) with a source-tagging technique. Anthropogenic emissions are from the Community Emissions Data System that is newly developed for the Coupled Model Intercomparison Project Phase 6 (CMIP6). Over north China where the air quality is often poor, about 90 % of near-surface BC concentration is contributed by local emissions. Overall, 35 % of BC concentration over south China in winter can be attributed to emissions from north China, and 19 % comes from sources outside China in spring. For other regions in China, BC is largely contributed from nonlocal sources. We further investigated potential factors that contribute to the poor air quality in China. During polluted days, a net inflow of BC transported from nonlocal source regions associated with anomalous winds plays an important role in increasing local BC concentrations. BC-containing particles emitted from East Asia can also be transported across the Pacific. Our model results show that emissions from inside and outside China are equally important for the BC outflow from East Asia, while emissions from China account for 8 % of BC concentration and 29 % in column burden in the western United States in spring. Radiative forcing estimates show that 65 % of the annual mean BC direct radiative forcing (2.2 W m -2 ) in China results from local emissions, and the remaining 35 % is contributed by emissions outside of China. Efficiency analysis shows that a reduction in BC emissions over eastern China could have a greater benefit for the regional air quality in China, especially in the winter haze season.

  1. Potential sensitivity of photosynthesis and isoprene emission to direct radiative effects of atmospheric aerosol pollution

    Directory of Open Access Journals (Sweden)

    S. Strada

    2016-04-01

    Full Text Available A global Earth system model is applied to quantify the impacts of direct anthropogenic aerosol effective radiative forcing on gross primary productivity (GPP and isoprene emission. The impacts of different pollution aerosol sources (anthropogenic, biomass burning, and non-biomass burning are investigated by performing sensitivity experiments. The model framework includes all known light and meteorological responses of photosynthesis, but uses fixed canopy structures and phenology. On a global scale, our results show that global land carbon fluxes (GPP and isoprene emission are not sensitive to pollution aerosols, even under a global decline in surface solar radiation (direct + diffuse by  ∼ 9 %. At a regional scale, GPP and isoprene emission show a robust but opposite sensitivity to pollution aerosols in regions where forested canopies dominate. In eastern North America and Eurasia, anthropogenic pollution aerosols (mainly from non-biomass burning sources enhance GPP by +5–8 % on an annual average. In the northwestern Amazon Basin and central Africa, biomass burning aerosols increase GPP by +2–5 % on an annual average, with a peak in the northwestern Amazon Basin during the dry-fire season (+5–8 %. The prevailing mechanism varies across regions: light scattering dominates in eastern North America, while a reduction in direct radiation dominates in Europe and China. Aerosol-induced GPP productivity increases in the Amazon and central Africa include an additional positive feedback from reduced canopy temperatures in response to increases in canopy conductance. In Eurasia and northeastern China, anthropogenic pollution aerosols drive a decrease in isoprene emission of −2 to −12 % on an annual average. Future research needs to incorporate the indirect effects of aerosols and possible feedbacks from dynamic carbon allocation and phenology.

  2. Radiation therapy in leukemia (total body irradiation excluded); Irradiations pour leucemie a l`exclusion de l`irradiation corporelle totale

    Energy Technology Data Exchange (ETDEWEB)

    Peiffert, D.; Hoffstetter, S. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France). Dept. de Radiotherapie

    1999-03-01

    Radiation techniques and indications in leukemias have been described in detail, yet prophylactic cranial irradiation in acute leukemia still has few indications. Cerebrospinal and testicular irradiation are reserved for relapsing disease. Radiation usually results in rapid functional improvement when used in neurologic emergencies and symptomatic neurologic or gross tumors relapses. Nevertheless, the improvements recently obtained by systemic chemotherapy have resulted in the reduction in the use of irradiation, especially in children, where it was considered deleterious with neuropsychological sequelae. Splenic irradiation remains useful for symptomatic myelo-proliferative syndrome. (authors)

  3. Radiation

    International Nuclear Information System (INIS)

    Winther, J.F.; Ulbak, K.; Dreyer, L.; Pukkala, E.; Oesterlind, A.

    1997-01-01

    Exposure to solar and ionizing radiation increases the risk for cancer in humans. Some 5% of solar radiation is within the ultraviolet spectrum and may cause both malignant melanoma and non-melanocytic skin cancer; the latter is regarded as a benign disease and is accordingly not included in our estimation of avoidable cancers. Under the assumption that the rate of occurrence of malignant melanoma of the buttocks of both men and women and of the scalp of women would apply to all parts of the body in people completely unexposed to solar radiation, it was estimated that approximately 95% of all malignant melanomas arising in the Nordic populations around the year 2000 will be due to exposure to natural ultraviolet radiation, equivalent to an annual number of about 4700 cases, with 2100 in men and 2600 in women, or some 4% of all cancers notified. Exposure to ionizing radiation in the Nordic countries occurs at an average effective dose per capita per year of about 3 mSv (Iceland, 1.1 mSv) from natural sources, and about 1 mSv from man-made sources. While the natural sources are primarily radon in indoor air, natural radionuclides in food, cosmic radiation and gamma radiation from soil and building materials, the man-made sources are dominated by the diagnostic and therapeutic use of ionizing radiation. On the basis of measured levels of radon in Nordic dwellings and associated risk estimates for lung cancer derived from well-conducted epidemiological studies, we estimated that about 180 cases of lung cancer (1% of all lung cancer cases) per year could be avoided in the Nordic countries around the year 2000 if indoor exposure to radon were eliminated, and that an additional 720 cases (6%) could be avoided annually if either radon or tobacco smoking were eliminated. Similarly, it was estimated that the exposure of the Nordic populations to natural sources of ionizing radiation other than radon and to medical sources will each give rise to an annual total of 2120

  4. Total water production capacity inversion phenomenon in multi-stage direct contact membrane distillation: A theoretical study

    KAUST Repository

    Lee, Jung Gil

    2017-09-09

    The low thermal efficiency and low water production are among the major challenges that prevent membrane distillation (MD) process from being commercialized. In an effort to design an efficient multi-stage direct contact MD (DCMD) unit through mathematical simulation, a new phenomenon that we refer to as total water production capacity inversion (WPI) has been detected. It is represented by a decrease in the total water production beyond a number of stages or a certain module length. WPI phenomenon, which was confirmed by using two different mathematical models validated experimentally, was found to take place due to the decrease in water vapor flux across the membrane as well as the increase in heat loss by conduction as the membrane length increases. Therefore, WPI should be considered as a critical MD design-criterion, especially for large scale units. Investigations conducted for a simulated multi-stage DCMD process showed that inlet feed and permeate temperatures difference, feed and permeate flow rates, and feed salinity have different effects on WPI. The number of stages (or module length at constant width) that leads to a maximum water production has been determined for different operating parameters. Decreasing inlet feed and permeate temperatures difference, or inlet feed and permeate flow rates and increasing inlet feed temperature at constant temperature difference or inlet feed salinity cause the WPI to take place at lower number of stages. Even though the feed salinity affects negligibly the mean permeate flux, it was clearly shown that it can affect WPI. The results presented herein unveil a hidden phenomenon that is likely to occur during process scale-up procedures and should be considered by process engineers for a proper choice of system design and operating conditions.

  5. Radiative corrections for the direct detection of neutralino dark matter and its relic density

    Energy Technology Data Exchange (ETDEWEB)

    Steppeler, Patrick Norbert

    2016-07-01

    In this thesis we calculate supersymmetric one-loop corrections of the strong interaction to elastic neutralino-nucleon scattering. The calculation is described in detail and performed in full generality within the Minimal Supersymmetric Standard Model (MSSM). In order to benefit from the well-established tensor reduction method, we have to stabilise the latter for vanishing Gram determinants. Afterwards the radiative corrections are matched onto an effective field theory based on the scalar operator anti χχ anti qq and the axial-vector operator anti χγ{sub 5}γ{sub μ}χ anti qγ{sub 5}γ{sup μ}q. This matching procedure is performed at the high scale μ{sub high}∝1000 GeV, whereas the associated nuclear matrix elements are defined at the low scale μ{sub low}∝5 GeV. To link both scales, the running of the effective operators and their corresponding Wilson coefficients is taken into account via renormalisation group equations. The lightest neutralino can be considered as a canonical example for a weakly interacting, massive particle which could constitute dark matter. To verify the existence of such particles, so-called direct detection experiments are conducted currently. These are based on the interaction between dark matter and nucleons. The leading contributions to the spin-independent and spin-dependent neutralino-nucleon cross sections are governed by the effective operators mentioned above, respectively. The calculation of the associated radiative corrections corresponds to a reduction of the theoretical uncertainty and permits to identify neutralino properties more reliably in case of positive findings and to set more robust exclusion bounds in case of negative findings. Furthermore, we calculate radiative corrections to annihilation and coannihilation processes of gauginos into quarks, where we focus again on supersymmetric one-loop corrections of the strong interaction. These processes contribute dominantly to the (co)annihilation cross section

  6. The direct effect of aerosols on solar radiation over the broader Mediterranean basin

    Directory of Open Access Journals (Sweden)

    C. D. Papadimas

    2012-08-01

    Full Text Available For the first time, the direct radiative effect (DRE of aerosols on solar radiation is computed over the entire Mediterranean basin, one of the most climatically sensitive world regions, using a deterministic spectral radiation transfer model (RTM. The DRE effects on the outgoing shortwave radiation at the top of atmosphere (TOA, DRETOA, on the absorption of solar radiation in the atmospheric column, DREatm, and on the downward and absorbed surface solar radiation (SSR, DREsurf and DREnetsurf, respectively, are computed separately. The model uses input data for the period 2000–2007 for various surface and atmospheric parameters, taken from satellite (International Satellite Cloud Climatology Project, ISCCP-D2, Global Reanalysis projects (National Centers for Environmental Prediction – National Center for Atmospheric Research, NCEP/NCAR, and other global databases. The spectral aerosol optical properties (aerosol optical depth, AOD, asymmetry parameter, gaer and single scattering albedo, ωaer, are taken from the MODerate resolution Imaging Spectroradiometer (MODIS of NASA (National Aeronautics and Space Administration and they are supplemented by the Global Aerosol Data Set (GADS. The model SSR fluxes have been successfully validated against measurements from 80 surface stations of the Global Energy Balance Archive (GEBA covering the period 2000–2007.

    A planetary cooling is found above the Mediterranean on an annual basis (regional mean DRETOA = −2.4 W m−2. Although a planetary cooling is found over most of the region, of up to −7 W m−2, large positive DRETOA values (up to +25 W m−2 are found over North Africa, indicating a strong planetary warming, and a weaker warming over the Alps (+0.5 W m−2. Aerosols are found to increase the absorption of solar radiation in the atmospheric

  7. Performance analysis of a direct expansion air dehumidification system combined with membrane-based total heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Cai-Hang; Zhang, Li-Zhi; Pei, Li-Xia [Key Laboratory of Enhanced Heat Transfer and Energy Conservation of Education Ministry, School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510640 (China)

    2010-09-15

    A direct expansion (DX) air dehumidification system is an efficient way to supply fresh and dry air to a built environment. It plays a key role in preventing the spread of respiratory disease like Swine flu (H1N1). To improve the efficiency of a conventional DX system in hot and humid regions, a new system of DX in combination with a membrane-based total heat exchanger is proposed. Air is supplied with dew points. A detailed mathematical modeling is performed. A cell-by-cell simulation technique is used to simulate its performances. A real prototype is built in our laboratory in South China University of Technology to validate the model. The effects of inlet air humidity and temperature, evaporator and condenser sizes on the system performance are investigated. The results indicate that the model can predict the system accurately. Compared to a conventional DX system, the air dehumidification rate (ADR) of the novel system is 0.5 times higher, and the coefficient of performance (COP) is 1 times higher. Furthermore, the system performs well even under harsh hot and humid weather conditions. (author)

  8. Direct determination of a radiation-damage profile with atomic resolution in ion-irradiated platinum. MSC report No. 5030

    International Nuclear Information System (INIS)

    Pramanik, D.; Seidman, D.N.

    1983-05-01

    The field-ion microscope (FIM) technique has been employed to determine directly a radiation damage profile, with atomic resolution, in a platinum specimen which had been irradiated at 80 0 K with 20-keV Kr + ions to a fluence of 5 x 10 12 cm - 2 . It is shown that the microscopic spatial-vacancy distribution (radiation-damage profile) is directly related to the elastically-deposited-energy profile. The experimentally constructed radiation-damage profile is compared with a theoretical damage profile - calculated employing the TRIM Monte Carlo code - and excellent agreement is obtained between the two, thus demonstrating that it is possible to go directly from a microscopic spatial distribution of vacancies to a continuous radiation-damage profile

  9. Effect of spectrally varying albedo of vegetation surfaces on shortwave radiation fluxes and aerosol direct radiative forcing

    Directory of Open Access Journals (Sweden)

    L. Zhu

    2012-12-01

    Full Text Available This study develops an algorithm for representing detailed spectral features of vegetation albedo based on Moderate Resolution Imaging Spectrometer (MODIS observations at 7 discrete channels, referred to as the MODIS Enhanced Vegetation Albedo (MEVA algorithm. The MEVA algorithm empirically fills spectral gaps around the vegetation red edge near 0.7 μm and vegetation water absorption features at 1.48 and 1.92 μm which cannot be adequately captured by the MODIS 7 channels. We then assess the effects of applying MEVA in comparison to four other traditional approaches to calculate solar fluxes and aerosol direct radiative forcing (DRF at the top of atmosphere (TOA based on the MODIS discrete reflectance bands. By comparing the DRF results obtained through the MEVA method with the results obtained through the other four traditional approaches, we show that filling the spectral gap of the MODIS measurements around 0.7 μm based on the general spectral behavior of healthy green vegetation leads to significant improvement in the instantaneous aerosol DRF at TOA (up to 3.02 W m−2 difference or 48% fraction of the aerosol DRF, −6.28 W m−2, calculated for high spectral resolution surface reflectance from 0.3 to 2.5 μm for deciduous vegetation surface. The corrections of the spectral gaps in the vegetation spectrum in the near infrared, again missed by the MODIS reflectances, also contributes to improving TOA DRF calculations but to a much lower extent (less than 0.27 W m−2, or about 4% of the instantaneous DRF.

    Compared to traditional approaches, MEVA also improves the accuracy of the outgoing solar flux between 0.3 to 2.5 μm at TOA by over 60 W m−2 (for aspen 3 surface and aerosol DRF by over 10 W m−2 (for dry grass. Specifically, for Amazon vegetation types, MEVA can improve the accuracy of daily averaged aerosol radiative forcing in the spectral range of 0.3 to 2.5 μm at

  10. Quantitative determination of the contribution of indirect and direct radiation action to the production of lethal lesions in mammalian cells

    International Nuclear Information System (INIS)

    Pohlit, W.; Drenkard, S.

    1985-01-01

    For quantitative models of radiation action in living cells it is necessary to know what fraction of the absorbed dose affects the target molecule by direct radiation action and what fraction by indirect radiation action. Mammalian cells were irradiated in suspension, saturated with N 2 O or CO 2 . With these gases the production of OH-radicals is changed by a factor of two in aqueous solutions and a corresponding change in cell survival would be expected, if only indirect radiation action is involved in the production of lethal lesions in the living cell. No difference could be detected, however, and it is concluded that indirect radiation action does not contribute to radiation lethality in mammalian cells. (author)

  11. A review of measurement-based assessments of the aerosol direct radiative effect and forcing

    Directory of Open Access Journals (Sweden)

    H. Yu

    2006-01-01

    Full Text Available Aerosols affect the Earth's energy budget directly by scattering and absorbing radiation and indirectly by acting as cloud condensation nuclei and, thereby, affecting cloud properties. However, large uncertainties exist in current estimates of aerosol forcing because of incomplete knowledge concerning the distribution and the physical and chemical properties of aerosols as well as aerosol-cloud interactions. In recent years, a great deal of effort has gone into improving measurements and datasets. It is thus feasible to shift the estimates of aerosol forcing from largely model-based to increasingly measurement-based. Our goal is to assess current observational capabilities and identify uncertainties in the aerosol direct forcing through comparisons of different methods with independent sources of uncertainties. Here we assess the aerosol optical depth (τ, direct radiative effect (DRE by natural and anthropogenic aerosols, and direct climate forcing (DCF by anthropogenic aerosols, focusing on satellite and ground-based measurements supplemented by global chemical transport model (CTM simulations. The multi-spectral MODIS measures global distributions of aerosol optical depth (τ on a daily scale, with a high accuracy of ±0.03±0.05τ over ocean. The annual average τ is about 0.14 over global ocean, of which about 21%±7% is contributed by human activities, as estimated by MODIS fine-mode fraction. The multi-angle MISR derives an annual average AOD of 0.23 over global land with an uncertainty of ~20% or ±0.05. These high-accuracy aerosol products and broadband flux measurements from CERES make it feasible to obtain observational constraints for the aerosol direct effect, especially over global the ocean. A number of measurement-based approaches estimate the clear-sky DRE (on solar radiation at the top-of-atmosphere (TOA to be about -5.5±0.2 Wm-2 (median ± standard error from various methods over the global ocean. Accounting for thin cirrus

  12. Respective roles of direct GHG radiative forcing and induced Arctic sea ice loss on the Northern Hemisphere atmospheric circulation

    Science.gov (United States)

    Oudar, Thomas; Sanchez-Gomez, Emilia; Chauvin, Fabrice; Cattiaux, Julien; Terray, Laurent; Cassou, Christophe

    2017-12-01

    The large-scale and synoptic-scale Northern Hemisphere atmospheric circulation responses to projected late twenty-first century Arctic sea ice decline induced by increasing Greenhouse Gases (GHGs) concentrations are investigated using the CNRM-CM5 coupled model. An original protocol, based on a flux correction technique, allows isolating the respective roles of GHG direct radiative effect and induced Arctic sea ice loss under RCP8.5 scenario. In winter, the surface atmospheric response clearly exhibits opposing effects between GHGs increase and Arctic sea ice loss, leading to no significant pattern in the total response (particularly in the North Atlantic region). An analysis based on Eady growth rate shows that Arctic sea ice loss drives the weakening in the low-level meridional temperature gradient, causing a general decrease of the baroclinicity in the mid and high latitudes, whereas the direct impact of GHGs increase is more located in the mid-to-high troposphere. Changes in the flow waviness, evaluated from sinuosity and blocking frequency metrics, are found to be small relative to inter-annual variability.

  13. Risk factors for radiation pneumonitis after stereotactic radiation therapy for lung tumours: clinical usefulness of the planning target volume to total lung volume ratio.

    Science.gov (United States)

    Ueyama, Tomoko; Arimura, Takeshi; Takumi, Koji; Nakamura, Fumihiko; Higashi, Ryutaro; Ito, Soichiro; Fukukura, Yoshihiko; Umanodan, Tomokazu; Nakajo, Masanori; Koriyama, Chihaya; Yoshiura, Takashi

    2018-06-01

    To identify risk factors for symptomatic radiation pneumonitis (RP) after stereotactic radiation therapy (SRT) for lung tumours. We retrospectively evaluated 68 lung tumours in 63 patients treated with SRT between 2011 and 2015. RP was graded according to the National Cancer Institute-Common Terminology Criteria for Adverse Events version 4.0. SRT was delivered at 7.0-12.0 Gy per each fraction, once daily, to a total of 48-64 Gy (median, 50 Gy). Univariate analysis was performed to assess patient- and treatment-related factors, including age, sex, smoking index (SI), pulmonary function, tumour location, serum Krebs von den Lungen-6 value (KL-6), dose-volume metrics (V5, V10, V20, V30, V40 and VS5), homogeneity index of the planning target volume (PTV), PTV dose, mean lung dose (MLD), contralateral MLD and V2, PTV volume, lung volume and the PTV/lung volume ratio (PTV/Lung). Performance of PTV/Lung in predicting symptomatic RP was also analysed using receiver operating characteristic (ROC) analysis. The median follow-up period was 21 months. 10 of 63 patients (15.9%) developed symptomatic RP after SRT. On univariate analysis, V10, V20, PTV volume and PTV/Lung were significantly associated with occurrence of RP  ≥Grade 2. ROC curves indicated that symptomatic RP could be predicted using PTV/Lung [area under curve (AUC): 0.88, confidence interval (CI: 0.78-0.95), cut-off value: 1.09, sensitivity: 90.0% and specificity: 72.4%]. PTV/Lung is a good predictor of symptomatic RP after SRT. Advances in knowledge: The cases with high PTV/Lung should be carefully monitored with caution for the occurrence of RP after SRT.

  14. A high-performance doped photocatalysts for inactivation of total coliforms in superficial waters using different sources of radiation.

    Science.gov (United States)

    Claro, Elis Marina Turini; Bidoia, Ederio Dino; de Moraes, Peterson Bueno

    2016-07-15

    Photocatalytic water treatment has a currently elevated electricity demand and maintenance costs, but the photocatalytic water treatment may also assist in overcoming the limitations and drawbacks of conventional water treatment processes. Among the Advanced Oxidation Processes, heterogeneous photocatalysis is one of the most widely and efficiently used processes to degrade and/or remove a wide range of polluting compounds. The goal of this work was to find out a highly efficient photocatalytic disinfection process in superficial water with different doped photocatalysts and using three sources of radiation: mercury vapor lamp, solar simulator and UV-A LED. Three doped photocatalysts were prepared, SiZnO, NSiZnO and FNSiZnO. The inactivation efficiency of each synthesized photocatalysts was compared to a TiO2 P25 (Degussa(®)) 0.5 g L(-1) control. Photolysis inactivation efficiency was 85% with UV-A LED, which is considered very high, demanding low electricity consumption in the process, whereas mercury vapor lamp and solar simulator yielded 19% and 13% inactivation efficiency, respectively. The best conditions were found with photocatalysts SiZnO, FNSiZnO and NSiZnO irradiated with UV-A LED, where efficiency exceeded 95% that matched inactivation of coliforms using the same irradiation and photocatalyst TiO2. All photocatalysts showed photocatalytic activity with all three radiation sources able to inactivate total coliforms from river water. The use of UV-A LED as the light source without photocatalyst is very promising, allowing the creation of cost-effective and highly efficient water treatment plants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Muscle Damage After Total Hip Arthroplasty Through the Direct Anterior Approach for Developmental Dysplasia of the Hip.

    Science.gov (United States)

    Kawasaki, Masashi; Hasegawa, Yukiharu; Okura, Toshiaki; Ochiai, Satoshi; Fujibayashi, Takayoshi

    2017-08-01

    Total hip arthroplasty (THA) through the direct anterior approach (DAA) is known to cause less muscle damage than other surgical approaches. However, more complex primary cases, such as developmental dysplasia of the hip (DDH), might often cause muscle damage. The objective of the present study was to clarify the muscle damage observed 1 year after THA through the DAA for DDH using magnetic resonance imaging. We prospectively compared the muscle cross-sectional area (M-CSA) and fatty atrophy (FA) in muscles by magnetic resonance imaging and the Harris hip score before and at 1-year follow-up after THA through the DAA in 3 groups: 37 patients with Crowe group 1 DDH (D1), 13 patients with Crowe group 2 and 3 DDH (D2 + 3), and 12 patients with osteonecrosis as a control. THA through the DAA for D1 displayed significantly decreased M-CSA and significantly increased FA in the gluteus minimus (Gmini), the tensor fasciae latae (TFL), and the obturator internus (OI). Patients with D2 + 3 group did not have decreased M-CSA in the TFL or increased FA in the Gmini. Postoperatively, a significant negative correlation was observed between the M-CSA and FA for the OI in patients with D1 and D2 + 3. THA through the DAA for DDH caused the damage in the Gmini, the TFL, and the OI; severe damage was observed in the OI, showing increased FA with decreased M-CSA in patients with both D1 and D2 + 3. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Preservation of the articular capsule and short lateral rotator in direct anterior approach to total hip arthroplasty.

    Science.gov (United States)

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko; Morohashi, Itaru

    2018-03-09

    In total hip arthroplasty via a direct anterior approach, the femur must be elevated at the time of femoral implant placement. For adequate elevation, division of the posterior soft tissues is necessary. However, if we damage and separate the posterior muscle tissue, we lose the benefits of the intermuscular approach. Furthermore, damage to the posterior soft tissue can result in posterior dislocation. We investigate that protecting the posterior soft tissue increases the joint stability in the early postoperative period and results in a lower dislocation rate. We evaluated muscle strength recovery by measuring the maximum width of the internal obturator muscle on CT images (GE-Healthcare Discovery CT 750HD). We compared the maximum width of the muscle belly preoperatively versus 10 days and 6 months postoperatively. As clinical evaluations, we also investigated the range of motion of the hip joint, hip joint function based on the Japanese Orthopaedic Association hip score (JOA score), and the dislocation rate 6 months after surgery. The width of the internal obturator muscle increased significantly from 15.1 ± 3.1 mm before surgery to 16.4 ± 2.8 mm 6 months after surgery. The JOA score improved significantly from 50.8 ± 15.1 points to 95.6 ± 7.6 points. No dislocations occurred in this study. We cut only the posterosuperior articular capsule and protected the internal obturator muscle to preserve muscle strength. We repaired the entire posterosuperior and anterior articular capsule. These treatments increase joint stability in the early postoperative period, thus reducing the dislocation rate. Therapeutic, Level IV.

  17. The possible direct use of satellite radiance measurements by the Atmospheric Radiation Measurement Program

    International Nuclear Information System (INIS)

    1993-03-01

    The Atmospheric Radiation Measurement (ARM) Program is a major research program initiated by the Department of Energy to improve our understanding of radiative and cloud processes critical to predicting the Earth's climate and its changes. Central to this concept is the use of four to six intensively instrumented sites for long-term study and characterization of the processes of interest. The instrumentation suites will include ground-based, high-accuracy radiometers for measuring the short and longwave surface flux, as well as an extensive set of ground-and air-based instrumentation for characterizing the intervening atmospheric column. Satellite-based measurements are expected to play a very important role in providing top-of-the-atmosphere measurements. In this study, we examine the possibility of comparing ARM outputs directly with satellite measurements, thereby ensuring the independence of these two important data sets. Thus we focused on what do satellites really measure and how well do they measure it. On what can we do about the general lack of adequate visible channel calibration. On what is the best way for ARM to obtain near-real-time access to this unprocessed data. And on what is the optimum way for ARM to make use of satellite data

  18. The FluxCompensator: Making Radiative Transfer Models of Hydrodynamical Simulations Directly Comparable to Real Observations

    Energy Technology Data Exchange (ETDEWEB)

    Koepferl, Christine M.; Robitaille, Thomas P., E-mail: koepferl@usm.lmu.de [Max Planck Institute for Astronomy, Königstuhl 17, D-69117 Heidelberg (Germany)

    2017-11-01

    When modeling astronomical objects throughout the universe, it is important to correctly treat the limitations of the data, for instance finite resolution and sensitivity. In order to simulate these effects, and to make radiative transfer models directly comparable to real observations, we have developed an open-source Python package called the FluxCompensator that enables the post-processing of the output of 3D Monte Carlo radiative transfer codes, such as Hyperion. With the FluxCompensator, realistic synthetic observations can be generated by modeling the effects of convolution with arbitrary point-spread functions, transmission curves, finite pixel resolution, noise, and reddening. Pipelines can be applied to compute synthetic observations that simulate observatories, such as the Spitzer Space Telescope or the Herschel Space Observatory . Additionally, this tool can read in existing observations (e.g., FITS format) and use the same settings for the synthetic observations. In this paper, we describe the package as well as present examples of such synthetic observations.

  19. The FluxCompensator: Making Radiative Transfer Models of Hydrodynamical Simulations Directly Comparable to Real Observations

    Science.gov (United States)

    Koepferl, Christine M.; Robitaille, Thomas P.

    2017-11-01

    When modeling astronomical objects throughout the universe, it is important to correctly treat the limitations of the data, for instance finite resolution and sensitivity. In order to simulate these effects, and to make radiative transfer models directly comparable to real observations, we have developed an open-source Python package called the FluxCompensator that enables the post-processing of the output of 3D Monte Carlo radiative transfer codes, such as Hyperion. With the FluxCompensator, realistic synthetic observations can be generated by modeling the effects of convolution with arbitrary point-spread functions, transmission curves, finite pixel resolution, noise, and reddening. Pipelines can be applied to compute synthetic observations that simulate observatories, such as the Spitzer Space Telescope or the Herschel Space Observatory. Additionally, this tool can read in existing observations (e.g., FITS format) and use the same settings for the synthetic observations. In this paper, we describe the package as well as present examples of such synthetic observations.

  20. Synchrotron radiation induced direct photo-etching and surface modification of PTFE

    International Nuclear Information System (INIS)

    Oshima, Akihiro; Washio, Masakazu

    2003-01-01

    In the first part of this article, we have described and discussed the measurement results of etching rates by direct photo-etching using Synchrotron Radiation (SR) for various kind of crosslinked PTFEs, which were prepared by different crosslinking doses, comparing with the non-crosslinked PTFE. It has been found that the etching rates obtained for crosslinked PTFE were much larger than that of non-crosslinked one. These results are not described by simple consideration such as the G values of main chain scission. We propose that the etching rates should be discussed by the complex mechanism through at least two different steps such as polymer decomposition and fragment desorption. In the second part of the article, we have described and discussed the abnormal reaction induced at the surface region after the SR etching for non-crosslinked PTFE. Through the measurements using DSC and solid state 19 F-NMR, we have confirmed the crosslinking reaction of PTFE even in solid state PTFE. This should be induced by the very high density radical formation in very thin area of PTFE films by SR radiation. (author)

  1. Markedly enhanced absorption and direct radiative forcing of black carbon under polluted urban environments.

    Science.gov (United States)

    Peng, Jianfei; Hu, Min; Guo, Song; Du, Zhuofei; Zheng, Jing; Shang, Dongjie; Levy Zamora, Misti; Zeng, Limin; Shao, Min; Wu, Yu-Sheng; Zheng, Jun; Wang, Yuan; Glen, Crystal R; Collins, Donald R; Molina, Mario J; Zhang, Renyi

    2016-04-19

    Black carbon (BC) exerts profound impacts on air quality and climate because of its high absorption cross-section over a broad range of electromagnetic spectra, but the current results on absorption enhancement of BC particles during atmospheric aging remain conflicting. Here, we quantified the aging and variation in the optical properties of BC particles under ambient conditions in Beijing, China, and Houston, United States, using a novel environmental chamber approach. BC aging exhibits two distinct stages, i.e., initial transformation from a fractal to spherical morphology with little absorption variation and subsequent growth of fully compact particles with a large absorption enhancement. The timescales to achieve complete morphology modification and an absorption amplification factor of 2.4 for BC particles are estimated to be 2.3 h and 4.6 h, respectively, in Beijing, compared with 9 h and 18 h, respectively, in Houston. Our findings indicate that BC under polluted urban environments could play an essential role in pollution development and contribute importantly to large positive radiative forcing. The variation in direct radiative forcing is dependent on the rate and timescale of BC aging, with a clear distinction between urban cities in developed and developing countries, i.e., a higher climatic impact in more polluted environments. We suggest that mediation in BC emissions achieves a cobenefit in simultaneously controlling air pollution and protecting climate, especially for developing countries.

  2. Stochastic Modeling of Direct Radiation Transmission in Particle-Laden Turbulent Flows

    Science.gov (United States)

    Banko, Andrew; Villafane, Laura; Kim, Ji Hoon; Esmaily Moghadam, Mahdi; Eaton, John K.

    2017-11-01

    Direct radiation transmission in turbulent flows laden with heavy particles plays a fundamental role in systems such as clouds, spray combustors, and particle-solar-receivers. Owing to their inertia, the particles preferentially concentrate and the resulting voids and clusters lead to deviations in mean transmission from the classical Beer-Lambert law for exponential extinction. Additionally, the transmission fluctuations can exceed those of Poissonian media by an order of magnitude, which implies a gross misprediction in transmission statistics if the correlations in particle positions are neglected. On the other hand, tracking millions of particles in a turbulence simulation can be prohibitively expensive. This work presents stochastic processes as computationally cheap reduced order models for the instantaneous particle number density field and radiation transmission therein. Results from the stochastic processes are compared to Monte Carlo Ray Tracing (MCRT) simulations using the particle positions obtained from the point-particle DNS of isotropic turbulence at a Taylor Reynolds number of 150. Accurate transmission statistics are predicted with respect to MCRT by matching the mean, variance, and correlation length of DNS number density fields. Funded by the U.S. Department of Energy under Grant No. DE-NA0002373-1 and the National Science Foundation under Grant No. DGE-114747.

  3. On some practical implications of the recent EU-directive on radiation protection

    International Nuclear Information System (INIS)

    Tschurlovits, M

    1998-01-01

    The following practical implications of the EU 96 directive on radiation protection in Austria are discussed: Quantitative justification and optimization of the recent standards is needed. The reduction of the annual dose limit to 20 mSv will affect a very small percentage of the persons subject to monitoring. The reduction of dose limits in external exposure of the population will not be dramatic at all. The model used to set up limits for internal exposure was changed to single intake; this implies some changes in design and monitoring. The deletion of convenient figures for 'unknown' radionuclides will make environmental and release monitoring more complex without gaining a higher level of protection. (A.K.)

  4. Effect of gamma-radiation on direct intercellular interaction (rosette formation) between thymus macrophages and thymocytes

    International Nuclear Information System (INIS)

    Belyakov, I.M.; Yarilin, A.A.

    1992-01-01

    In experiments with mice, the effect of radiation on resette formation between thymus macrophages (Th-MPh) and thymocytes (Thc) was studied on days 1, 4, 12, 30, and 60 following gamma-irradiation with doses of 0.5, 2, 4, and 8 Gy. gamma-Irradiation with doses of above 2 Gy was shown to cause a dose-dependent inhibition of rosette formation of Th-MPh with Thc in vitro. Two types of rosette-forming Th-MPh were identified: RFMPhII with low rate of binding to Thc and RFMPhII with high rate of binding to Thc. Radiation affects mainly the RFMPhII content. The total population of rosette-forming Th-MPh was restored on day 60 mainly due to cells with low rate of rosette formation. The EC supernatant promoted rosette formation of exposed Th-MPh with Thc. The effect was maximum at early times following irradiation of Th-MPh with a dose of 4 Gy

  5. The direct and inverse problems of an air-saturated poroelastic cylinder submitted to acoustic radiation

    Directory of Open Access Journals (Sweden)

    Erick Ogam

    2011-09-01

    Full Text Available A wave-fluid saturated poroelastic structure interaction model based on the modified Biot theory (MBT and plane-wave decomposition using orthogonal cylindrical functions is developed. The model is employed to recover from real data acquired in an anechoic chamber, the poromechanical properties of a soft cellular melamine cylinder submitted to an audible acoustic radiation. The inverse problem of acoustic diffraction is solved by constructing the objective functional given by the total square of the difference between predictions from the MBT interaction model and diffracted field data from experiment. The faculty of retrieval of the intrinsic poromechanical parameters from the diffracted acoustic fields, indicate that a wave initially propagating in a light fluid (air medium, is able to carry in the absence of mechanical excitation of the specimen, information on the macroscopic mechanical properties which depend on the microstructural and intrinsic properties of the solid phase.

  6. An Evaluation of Semiempirical Models for Partitioning Photosynthetically Active Radiation Into Diffuse and Direct Beam Components

    Science.gov (United States)

    Oliphant, Andrew J.; Stoy, Paul C.

    2018-03-01

    Photosynthesis is more efficient under diffuse than direct beam photosynthetically active radiation (PAR) per unit PAR, but diffuse PAR is infrequently measured at research sites. We examine four commonly used semiempirical models (Erbs et al., 1982, https://doi.org/10.1016/0038-092X(82)90302-4; Gu et al., 1999, https://doi.org/10.1029/1999JD901068; Roderick, 1999, https://doi.org/10.1016/S0168-1923(99)00028-3; Weiss & Norman, 1985, https://doi.org/10.1016/0168-1923(85)90020-6) that partition PAR into diffuse and direct beam components based on the negative relationship between atmospheric transparency and scattering of PAR. Radiation observations at 58 sites (140 site years) from the La Thuille FLUXNET data set were used for model validation and coefficient testing. All four models did a reasonable job of predicting the diffuse fraction of PAR (ϕ) at the 30 min timescale, with site median r2 values ranging between 0.85 and 0.87, model efficiency coefficients (MECs) between 0.62 and 0.69, and regression slopes within 10% of unity. Model residuals were not strongly correlated with astronomical or standard meteorological variables. We conclude that the Roderick (1999, https://doi.org/10.1016/S0168-1923(99)00028-3) and Gu et al. (1999, https://doi.org/10.1029/1999JD901068) models performed better overall than the two older models. Using the basic form of these models, the data set was used to find both individual site and universal model coefficients that optimized predictive accuracy. A new universal form of the model is presented in section 5 that increased site median MEC to 0.73. Site-specific model coefficients increased median MEC further to 0.78, indicating usefulness of local/regional training of coefficients to capture the local distributions of aerosols and cloud types.

  7. Effect of radiation dose rate and cyclophosphamide on pulmonary toxicity after total body irradiation in a mouse model

    International Nuclear Information System (INIS)

    Safwat, Akmal; Nielsen, Ole S.; El-Badawy, Samy; Overgaard, Jens

    1996-01-01

    Purpose: Interstitial pneumonitis (IP) is still a major complication after total body irradiation (TBI) and bone marrow transplantation (BMT). It is difficult to determine the exact role of radiation in this multifactorial complication, especially because most of the experimental work on lung damage was done using localized lung irradiation and not TBI. We have thus tested the effect of radiation dose rate and combining cyclophosphamide (CTX) with single fraction TBI on lung damage in a mouse model for BMT. Methods and Materials: TBI was given as a single fraction at a high dose rate (HDR, 0.71 Gy/min) or a low dose rate (LDR, 0.08 Gy/min). CTX (250 mg/kg) was given 24 h before TBI. Bone marrow transplantation (BMT) was performed 4-6 h after the last treatment. Lung damage was assessed using ventilation rate (VR) and lethality between 28 and 180 days (LD (50(28))-180 ). Results: The LD 50 for lung damage, ± standard error (SE), increased from 12.0 (± 0.2) Gy using single fraction HDR to 15.8 (± 0.6) Gy using LDR. Adding CTX shifted the dose-response curves towards lower doses. The LD 50 values for the combined treatment were 5.3 (± 0.2) and 3.5 (± 0.2) Gy for HDR and LDR, respectively. This indicates that the combined effect of CTX and LDR was more toxic than that of combined CTX and HDR. Lung damage evaluated by VR demonstrated two waves of VR increase. The first wave of VR increase occurred after 6 weeks using TBI only and after 3 weeks in the combined CTX-TBI treatment, irrespective of total dose or dose rate. The second wave of VR elevation resembled the IP that follows localized thoracic irradiation in its time of occurrence. Conclusions: Lung damage following TBI could be spared using LDR. However, CTX markedly enhances TBI-induced lung damage. The combination of CTX and LDR is more toxic to the lungs than combining CTX and HDR

  8. Modelling derecho dynamics and the direct radiative effect of wildfire smoke upon it with NWP model HARMONIE

    Science.gov (United States)

    Toll, Velle; Männik, Aarne

    2014-05-01

    Convection permitting numerical weather prediction model HARMONIE was used to simulate the dynamics of the derecho that swept over Eastern Europe on August 8, 2010. The storm moved over Belarus, Lithuania, Latvia, Estonia and Finland and the strongest wind gusts (up to 36.5 m/s) were measured in Estonia. The storm path is recorded on the radar images where characteristic bow echo was observed. The model setup was similar to near-future operational, nearly kilometre-scale environments in European national weather services. Hindcast experiments show the ability of the HARMONIE model to predict the severe convective storm and forecast concurrent strong wind gusts. Wind gusts with very similar intensity to observed ones were simulated by the HARMONIE model and 2.5-km horizontal resolution appears sufficient for reliable forecast of the derecho event. The timing of the modelled storm was in good agreement with the observations. The simulated average storm propagation speed was 25 m/s, similar to the radar observations. Hindcast experiments suggest that more precise warning for the storm could have been issued if the HARMONIE model would have been utilised. The derecho event was accompanied by the remarkable smoke aerosol concentrations (maximum total aerosol optical depth more than 4 at 550 nm) originating from the wildfires from Russia. Smoke plume travelled clockwise around Moscow from August 5 to 9. On August 8, 2010, smoke plume was situated on the Eastern border of Estonia. The derecho occurred on the western side of the smoke plume path. HARMONIE experiments were performed to study the direct radiative effect of wildfire smoke on a severe convective storm. The impact of smoke aerosol on the derecho dynamics was investigated. Reduction in the shortwave radiation flux at the surface resulting from aerosol influence simulated by the HARMONIE model is up to 200 W/m2 in the area with the highest aerosol concentrations. This causes near surface cooling of up to 3 º

  9. Seedling establishment and distribution of direct radiation in slit-shaped openings of Norway spruce forests in the intermediate Alps

    International Nuclear Information System (INIS)

    Brang, P.

    1996-01-01

    Direct radiation is crucial for Norway spruce (Picea abies (L.) Karst.) seedling establishment in high-montane and subalpine spruce forests. Fisheye photography was used to estimate the daily distribution of direct radiation in small forest openings on a north-northwest and a south facing slope near Sedrun (Grisons, Switzerland). In slit-shaped openings on the north-northwest facing slope long sunflecks mostly occurred in the afternoon, when the sun shines parallel to the slit axis. This is in accordance to the silvicultural intention. However, since the stands are clumpy and therefore pervious to sunlight, the daily sunfleck distribution is fairly even notwithstanding the slit orientation, and direct radiation at noon is the dominant form of incident energy. In small circular to rectangular openings on the south facing slope direct radiation peaks at noontide. A seeding trial imitating natural seedling establishment was set in place in openings on both slopes. Based on this trial, the relations among seedling establishment, aspect, slit shape, size, and orientation are discussed for Norway spruce forests in the intermediate Alps. The directional weather factors such as radiation and precipitation can be highly influenced by slits, which is why suitable microclimate for seedling establishment can be promoted provided the slits are oriented appropriately. Slits in which the most insolated edges are oriented windward are especially favourable

  10. Aerosol direct radiative effects over the northwest Atlantic, northwest Pacific, and North Indian Oceans: estimates based on in-situ chemical and optical measurements and chemical transport modeling

    Directory of Open Access Journals (Sweden)

    T. S. Bates

    2006-01-01

    Full Text Available The largest uncertainty in the radiative forcing of climate change over the industrial era is that due to aerosols, a substantial fraction of which is the uncertainty associated with scattering and absorption of shortwave (solar radiation by anthropogenic aerosols in cloud-free conditions (IPCC, 2001. Quantifying and reducing the uncertainty in aerosol influences on climate is critical to understanding climate change over the industrial period and to improving predictions of future climate change for assumed emission scenarios. Measurements of aerosol properties during major field campaigns in several regions of the globe during the past decade are contributing to an enhanced understanding of atmospheric aerosols and their effects on light scattering and climate. The present study, which focuses on three regions downwind of major urban/population centers (North Indian Ocean (NIO during INDOEX, the Northwest Pacific Ocean (NWP during ACE-Asia, and the Northwest Atlantic Ocean (NWA during ICARTT, incorporates understanding gained from field observations of aerosol distributions and properties into calculations of perturbations in radiative fluxes due to these aerosols. This study evaluates the current state of observations and of two chemical transport models (STEM and MOZART. Measurements of burdens, extinction optical depth (AOD, and direct radiative effect of aerosols (DRE – change in radiative flux due to total aerosols are used as measurement-model check points to assess uncertainties. In-situ measured and remotely sensed aerosol properties for each region (mixing state, mass scattering efficiency, single scattering albedo, and angular scattering properties and their dependences on relative humidity are used as input parameters to two radiative transfer models (GFDL and University of Michigan to constrain estimates of aerosol radiative effects, with uncertainties in each step propagated through the analysis. Constraining the radiative

  11. Quantifying the climatological cloud-free direct radiative forcing of aerosol over the Red Sea

    KAUST Repository

    Brindley, Helen

    2015-04-01

    A combination of ground-based and satellite observations are used, in conjunction with column radiative transfer modelling, to assess the climatological aerosol loading and quantify its corresponding cloud-free direct radiative forcing (DRF) over the Red Sea. While there have been campaigns designed to probe aerosol-climate interactions over much of the world, relatively little attention has been paid to this region. Because of the remoteness of the area, satellite retrievals provide a crucial tool for assessing aerosol loading over the Sea. However, agreement between aerosol properties inferred from measurements from different instruments, and even in some cases from the same measurements using different retrieval algorithms can be poor, particularly in the case of mineral dust. Ground based measurements which can be used to evaluate retrievals are thus highly desirable. Here we take advantage of ship-based sun-photometer micro-tops observations gathered from a series of cruises which took place across the Red Sea during 2011 and 2013. To our knowledge these data represent the first set of detailed aerosol measurements from the Sea. They thus provide a unique opportunity to assess the performance of satellite retrieval algorithms in this region. Initially two aerosol optical depth (AOD) retrieval algorithms developed for the MODerate Resolution Imaging Spectroradiometer (MODIS) and Spinning Enhanced Visible and InfraRed Imager (SEVIRI) instruments are evaluated via comparison with the co-located cruise observations. These show excellent agreement, with correlations typically better than 0.9 and very small root-mean-square and bias differences. Calculations of radiative fluxes and DRF along one of the cruises using the observed aerosol and meteorological conditions also show good agreement with co-located estimates from the Geostationary Earth Radiation Budget (GERB) instrument if the aerosol asymmetry parameter is adjusted to account for the presence of large

  12. A set cover approach to fast beam orientation optimization in intensity modulated radiation therapy for total marrow irradiation

    International Nuclear Information System (INIS)

    Lee, Chieh-Hsiu Jason; Aleman, Dionne M; Sharpe, Michael B

    2011-01-01

    The beam orientation optimization (BOO) problem in intensity modulated radiation therapy (IMRT) treatment planning is a nonlinear problem, and existing methods to obtain solutions to the BOO problem are time consuming due to the complex nature of the objective function and size of the solution space. These issues become even more difficult in total marrow irradiation (TMI), where many more beams must be used to cover a vastly larger treatment area than typical site-specific treatments (e.g., head-and-neck, prostate, etc). These complications result in excessively long computation times to develop IMRT treatment plans for TMI, so we attempt to develop methods that drastically reduce treatment planning time. We transform the BOO problem into the classical set cover problem (SCP) and use existing methods to solve SCP to obtain beam solutions. Although SCP is NP-Hard, our methods obtain beam solutions that result in quality treatments in minutes. We compare our approach to an integer programming solver for the SCP to illustrate the speed advantage of our approach.

  13. A set cover approach to fast beam orientation optimization in intensity modulated radiation therapy for total marrow irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chieh-Hsiu Jason; Aleman, Dionne M [Department of Mechanical and Industrial Engineering, University of Toronto, 5 King' s College Road, Toronto, ON M5S 3G8 (Canada); Sharpe, Michael B, E-mail: chjlee@mie.utoronto.ca, E-mail: aleman@mie.utoronto.ca, E-mail: michael.sharpe@rmp.uhn.on.ca [Princess Margaret Hospital, Department of Radiation Oncology, University of Toronto, 610 University Avenue, Toronto, ON M5G 2M9 (Canada)

    2011-09-07

    The beam orientation optimization (BOO) problem in intensity modulated radiation therapy (IMRT) treatment planning is a nonlinear problem, and existing methods to obtain solutions to the BOO problem are time consuming due to the complex nature of the objective function and size of the solution space. These issues become even more difficult in total marrow irradiation (TMI), where many more beams must be used to cover a vastly larger treatment area than typical site-specific treatments (e.g., head-and-neck, prostate, etc). These complications result in excessively long computation times to develop IMRT treatment plans for TMI, so we attempt to develop methods that drastically reduce treatment planning time. We transform the BOO problem into the classical set cover problem (SCP) and use existing methods to solve SCP to obtain beam solutions. Although SCP is NP-Hard, our methods obtain beam solutions that result in quality treatments in minutes. We compare our approach to an integer programming solver for the SCP to illustrate the speed advantage of our approach.

  14. Paraphyseal changes on bone-age studies predict risk of delayed radiation-associated skeletal complications following total body irradiation

    International Nuclear Information System (INIS)

    Kitazono Hammell, Mary T.; Edgar, J.C.; Jaramillo, Diego; Bunin, Nancy

    2013-01-01

    Children undergoing total body irradiation (TBI) often develop delayed skeletal complications. Bone-age studies in these children often reveal subtle paraphyseal changes including physeal widening, metaphyseal irregularity and paraphyseal exostoses. To investigate whether paraphyseal changes on a bone-age study following TBI indicate a predisposition toward developing other radiation-associated skeletal complications. We retrospectively reviewed medical records and bone-age studies of 77 children receiving TBI at our institution between 1995 and 2008 who had at least 2 years of clinical follow-up and one bone-age study after TBI. We graded bone-age studies according to the severity of paraphyseal changes. All documented skeletal complications following TBI were tabulated. Kendall's tau-b was used to examine associations between degree of paraphyseal change and development of a skeletal complication. Kendall's tau analyses showed that physeal widening and metaphyseal irregularity/sclerosis (tau = 0.87, P < 0.001) and paraphyseal exostoses (tau = 0.68, P < 0.001) seen on bone-age studies were significantly positively associated with the development of delayed skeletal complications following TBI. Thirty percent of children with no or mild paraphyseal changes developed a delayed skeletal complication, compared with 58% of children with moderate paraphyseal changes and 90% of children with severe paraphyseal changes. Paraphyseal changes identified on a bone-age study correlate positively with the development of delayed skeletal complications elsewhere in the skeleton following TBI. (orig.)

  15. Yield of Prompt Gamma Radiation in Slow-Neutron Induced Fission of 235U as a Function of the Total Fragment Kinetic Energy

    Energy Technology Data Exchange (ETDEWEB)

    Albinsson, H [Chalmers Univ. of Technology, Goeteborg (SE)

    1971-07-01

    Fission gamma radiation yields as functions of the total fragment kinetic energy were obtained for 235U thermal-neutron induced fission. The fragments were detected with silicon surface-barrier detectors and the gamma radiation with a Nal(Tl) scintillator. In some of the measurements mass selection was used so that the gamma radiation could also be measured as a function of fragment mass. Time discrimination between the fission gammas and the prompt neutrons released in the fission process was employed to reduce the background. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fission fragments. Fission-neutron and gamma-ray data of previous experiments were used for comparisons of the yields, and estimates were made of the variation of the prompt gamma-ray energy with the total fragment kinetic energy

  16. Use of a solar panel as a directionally sensitive large-area radiation monitor for direct and scattered x-rays and gamma-rays.

    Science.gov (United States)

    Abdul-Majid, S

    1987-01-01

    The characteristics of a 25.4 X 91 cm solar cell panel used as an x-ray and gamma-ray radiation monitor are presented. Applications for monitoring the primary x-ray beam are described at different values of operating currents and voltages as well as for directional dependence of scattered radiation. Other applications in gamma-ray radiography are also given. The detector showed linear response to both x-ray and gamma-ray exposures. The equipment is rigid, easy to use, relatively inexpensive and requires no power supply or any complex electronic equipment.

  17. Nanostructure of PDMS–TEOS–PrZr hybrids prepared by direct deposition of gamma radiation energy

    International Nuclear Information System (INIS)

    Lancastre, Joana J.H.; Falcão, António N.; Margaça, Fernanda M.A.; Ferreira, Luís M.; Miranda Salvado, Isabel M.; Almásy, László; Casimiro, Maria H.; Meiszterics, Anikó

    2015-01-01

    Highlights: • Hybrid materials were prepared by direct energy deposition. • The influence of the catalyst content (PrZr) was investigated. • The developed oxide network was found to be strongly dependent on the PrZr content. • A model is proposed for the development of the oxide network in these materials. - Abstract: Organic–inorganic materials have been the object of intense research due to their wide range of properties and therefore innumerous applications. We prepared organic–inorganic hybrid materials by direct energy deposition on a mixture of polydimethylsiloxane silanol terminated (33 wt% fixed content), tetraethylorthosilicate and a minor content of zirconium propoxide that varied from 1 to 5 wt% using gamma radiation from a Co-60 source. The samples, dried in air at room temperature, are bulk, flexible and transparent. Their nanostructure was investigated by small angle neutron scattering. It was found that the inorganic oxide network has fractal structure, which becomes denser as the zirconium propoxide content decreases. The results suggest that oxide nanosized regions grow from the OH terminal group of PDMS which are the condensation seeds. Their number and position remains unaltered with the variation of zirconium propoxide content that only affects their microstructure. A model is proposed for the nanostructure of the oxide network that develops in the irradiation processed hybrid materials.

  18. Nanostructure of PDMS–TEOS–PrZr hybrids prepared by direct deposition of gamma radiation energy

    Energy Technology Data Exchange (ETDEWEB)

    Lancastre, Joana J.H., E-mail: jlancastre@ctn.ist.utl.pt [C2TN, Instituto Superior Técnico, Universidade de Lisboa, E.N. 10 (km 139.7), 2695-066 Bobadela, LRS (Portugal); Falcão, António N. [C2TN, Instituto Superior Técnico, Universidade de Lisboa, E.N. 10 (km 139.7), 2695-066 Bobadela, LRS (Portugal); Margaça, Fernanda M.A., E-mail: fmargaca@ctn.ist.utl.pt [C2TN, Instituto Superior Técnico, Universidade de Lisboa, E.N. 10 (km 139.7), 2695-066 Bobadela, LRS (Portugal); Ferreira, Luís M. [C2TN, Instituto Superior Técnico, Universidade de Lisboa, E.N. 10 (km 139.7), 2695-066 Bobadela, LRS (Portugal); Miranda Salvado, Isabel M. [CICECO & Departamento de Engenharia de Materiais e Cerâmica, Universidade de Aveiro, Campus de Santiago, 3810-193 Aveiro (Portugal); Almásy, László [Wigner Research Centre for Physics, Institute for Solid State Physics and Optics, PO Box 49, 1525 Budapest (Hungary); Casimiro, Maria H. [REQUIMTE/CQFB, Departamento de Química, Faculdade de Ciências e Tecnologia, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Meiszterics, Anikó [Gedeon Richter Ltd., PO Box 27, H-1475 Budapest (Hungary)

    2015-10-15

    Highlights: • Hybrid materials were prepared by direct energy deposition. • The influence of the catalyst content (PrZr) was investigated. • The developed oxide network was found to be strongly dependent on the PrZr content. • A model is proposed for the development of the oxide network in these materials. - Abstract: Organic–inorganic materials have been the object of intense research due to their wide range of properties and therefore innumerous applications. We prepared organic–inorganic hybrid materials by direct energy deposition on a mixture of polydimethylsiloxane silanol terminated (33 wt% fixed content), tetraethylorthosilicate and a minor content of zirconium propoxide that varied from 1 to 5 wt% using gamma radiation from a Co-60 source. The samples, dried in air at room temperature, are bulk, flexible and transparent. Their nanostructure was investigated by small angle neutron scattering. It was found that the inorganic oxide network has fractal structure, which becomes denser as the zirconium propoxide content decreases. The results suggest that oxide nanosized regions grow from the OH terminal group of PDMS which are the condensation seeds. Their number and position remains unaltered with the variation of zirconium propoxide content that only affects their microstructure. A model is proposed for the nanostructure of the oxide network that develops in the irradiation processed hybrid materials.

  19. Direct-aperture optimization applied to selection of beam orientations in intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Bedford, J L; Webb, S

    2007-01-01

    Direct-aperture optimization (DAO) was applied to iterative beam-orientation selection in intensity-modulated radiation therapy (IMRT), so as to ensure a realistic segmental treatment plan at each iteration. Nested optimization engines dealt separately with gantry angles, couch angles, collimator angles, segment shapes, segment weights and wedge angles. Each optimization engine performed a random search with successively narrowing step sizes. For optimization of segment shapes, the filtered backprojection (FBP) method was first used to determine desired fluence, the fluence map was segmented, and then constrained direct-aperture optimization was used thereafter. Segment shapes were fully optimized when a beam angle was perturbed, and minimally re-optimized otherwise. The algorithm was compared with a previously reported method using FBP alone at each orientation iteration. An example case consisting of a cylindrical phantom with a hemi-annular planning target volume (PTV) showed that for three-field plans, the method performed better than when using FBP alone, but for five or more fields, neither method provided much benefit over equally spaced beams. For a prostate case, improved bladder sparing was achieved through the use of the new algorithm. A plan for partial scalp treatment showed slightly improved PTV coverage and lower irradiated volume of brain with the new method compared to FBP alone. It is concluded that, although the method is computationally intensive and not suitable for searching large unconstrained regions of beam space, it can be used effectively in conjunction with prior class solutions to provide individually optimized IMRT treatment plans

  20. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Amberger, Martin A.; Hoeltig, Michael; Broekaert, Jose A.C.

    2010-01-01

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL -1 . As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL -1 of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 μg g -1 for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al 2 O 3 , powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective samples over a

  1. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Amberger, Martin A.; Hoeltig, Michael [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany); Broekaert, Jose A.C., E-mail: jose.broekaert@chemie.uni-hamburg.d [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany)

    2010-02-15

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL{sup -1}. As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL{sup -1} of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 mug g{sup -1} for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al{sub 2}O{sub 3}, powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective

  2. Radiation protection and safety in medical use of ionising radiation in Republic of Bulgaria - Harmonisation of the national legislation with Euratom directives

    International Nuclear Information System (INIS)

    Ingilizova, K.; Vassileva, J.; Rupova, I.; Pavlova, A.

    2005-01-01

    From February 2002 to November 2003 the National Centre of Radiobiology and Radiation Protection conducted a PHARE twinning project 'Radiation Protection and Safety at Medical Use of Ionising Radiation'. The main purposes of the project were the harmonisation of Bulgarian legislation in the field of radiation protection with EC Directives 96/29 and 97/43 Euratom, and the establishment of appropriate institutional infrastructure and administrative framework for their implementation. This paper presents the main results of the project: elaboration of Ordinance for Protection of Individuals from Medical Exposure; performance of a national survey of distribution of patient doses in diagnostic radiology and of administered activities in nuclear medicine and establishment of national reference levels for the most common diagnostic procedures. (authors)

  3. Radiation closure and diurnal cycle of the clear-sky dust instantaneous direct radiative forcing over Arabian Peninsula

    KAUST Repository

    Osipov, Sergey; Stenchikov, Georgiy L.; Brindley,  Helen; Banks,  Jamie

    2015-01-01

    Spinning Enhanced Visible and Infrared Imager (SEVIRI) aerosol optical depth. Results are compared with Geostationary Earth Radiation Budget (GERB) derived top of the atmosphere climatological forcing over the Red Sea.

  4. Time- and radiation-dose dependent changes in the plasma proteome after total body irradiation of non-human primates: Implications for biomarker selection.

    Directory of Open Access Journals (Sweden)

    Stephanie D Byrum

    Full Text Available Acute radiation syndrome (ARS is a complex multi-organ disease resulting from total body exposure to high doses of radiation. Individuals can be exposed to total body irradiation (TBI in a number of ways, including terrorist radiological weapons or nuclear accidents. In order to determine whether an individual has been exposed to high doses of radiation and needs countermeasure treatment, robust biomarkers are needed to estimate radiation exposure from biospecimens such as blood or urine. In order to identity such candidate biomarkers of radiation exposure, high-resolution proteomics was used to analyze plasma from non-human primates following whole body irradiation (Co-60 at 6.7 Gy and 7.4 Gy with a twelve day observation period. A total of 663 proteins were evaluated from the plasma proteome analysis. A panel of plasma proteins with characteristic time- and dose-dependent changes was identified. In addition to the plasma proteomics study reported here, we recently identified candidate biomarkers using urine from these same non-human primates. From the proteomic analysis of both plasma and urine, we identified ten overlapping proteins that significantly differentiate both time and dose variables. These shared plasma and urine proteins represent optimal candidate biomarkers of radiation exposure.

  5. Deep-water measurements of container ship radiated noise signatures and directionality.

    Science.gov (United States)

    Gassmann, Martin; Wiggins, Sean M; Hildebrand, John A

    2017-09-01

    Underwater radiated noise from merchant ships was measured opportunistically from multiple spatial aspects to estimate signature source levels and directionality. Transiting ships were tracked via the Automatic Identification System in a shipping lane while acoustic pressure was measured at the ships' keel and beam aspects. Port and starboard beam aspects were 15°, 30°, and 45° in compliance with ship noise measurements standards [ANSI/ASA S12.64 (2009) and ISO 17208-1 (2016)]. Additional recordings were made at a 10° starboard aspect. Source levels were derived with a spherical propagation (surface-affected) or a modified Lloyd's mirror model to account for interference from surface reflections (surface-corrected). Ship source depths were estimated from spectral differences between measurements at different beam aspects. Results were exemplified with a 4870 and a 10 036 twenty-foot equivalent unit container ship at 40%-56% and 87% of service speeds, respectively. For the larger ship, opportunistic ANSI/ISO broadband levels were 195 (surface-affected) and 209 (surface-corrected) dB re 1 μPa 2 1 m. Directionality at a propeller blade rate of 8 Hz exhibited asymmetries in stern-bow (<6 dB) and port-starboard (<9 dB) direction. Previously reported broadband levels at 10° aspect from McKenna, Ross, Wiggins, and Hildebrand [(2012b). J. Acoust. Soc. Am. 131, 92-103] may be ∼12 dB lower than respective surface-affected ANSI/ISO standard derived levels.

  6. Aerosol direct effect on solar radiation over the eastern Mediterranean Sea based on AVHRR satellite measurements

    Science.gov (United States)

    Georgakaki, Paraskevi; Papadimas, Christos D.; Hatzianastassiou, Nikos; Fotiadi, Aggeliki; Matsoukas, Christos; Stackhouse, Paul; Kanakidou, Maria; Vardavas, Ilias M.

    2017-04-01

    Despite the improved scientific understanding of the direct effect of aerosols on solar radiation (direct radiative effect, DRE) improvements are necessary, for example regarding the accuracy of the magnitude of estimated DREs and their spatial and temporal variability. This variability cannot be ensured by in-situ surface and airborne measurements, while it is also relatively difficult to capture through satellite observations. This becomes even more difficult when complete spatial coverage of extended areas is required, especially concerning areas that host various aerosol types with variable physico-chemical and optical aerosol properties. Better assessments of aerosol DREs are necessary, relying on aerosol optical properties with high spatial and temporal variation. The present study aims to provide a refined, along these lines, assessment of aerosol DREs over the eastern Mediterranean (EM) Sea, which is a key area for aerosol studies. Daily DREs are computed for 1˚ x1˚ latitude-longitude grids with the FORTH detailed spectral radiation transfer model (RTM) using input data for various atmospheric and surface parameters, such as clouds, water vapor, ozone and surface albedo, taken from the NASA-Langley Global Earth Observing System (GEOS) database. The model spectral aerosol optical depth (AOD), single scattering albedo and asymmetry parameter are taken from the Global Aerosol Data Set and the NOAA Climate Data Record (CDR) version 2 of Advanced Very High resolution Radiometer (AVHRR) AOD dataset which is available over oceans at 0.63 microns and at 0.1˚ x0.1˚ . The aerosol DREs are computed at the surface, the top-of-atmosphere and within the atmosphere, over the period 1985-1995. Preliminary model results for the period 1990-1993 reveal a significant spatial and temporal variability of DREs over the EM Sea, for example larger values over the Aegean and Black Seas, surrounded by land areas with significant anthropogenic aerosol sources, and over the

  7. Patient radiation exposure dose evaluation of whole spine scanography due to exposure direction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Seo, Deok Nam [Dept. of Bio-convergence Engineering, Graduate School of Korea University, Seoul (Korea, Republic of); Kwon, Soon Mu [Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Science, Korea University, Seoul (Korea, Republic of)

    2015-04-15

    Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefore we need to redefine of protocol for digital radiography such as WSS, whole spine scanography, effective dose, patient exposure dose, exposure direction, protocol optimization.

  8. Vertical profiles of BC direct radiative effect over Italy: high vertical resolution data and atmospheric feedbacks

    Science.gov (United States)

    Močnik, Griša; Ferrero, Luca; Castelli, Mariapina; Ferrini, Barbara S.; Moscatelli, Marco; Grazia Perrone, Maria; Sangiorgi, Giorgia; Rovelli, Grazia; D'Angelo, Luca; Moroni, Beatrice; Scardazza, Francesco; Bolzacchini, Ezio; Petitta, Marcello; Cappelletti, David

    2016-04-01

    Black carbon (BC), and its vertical distribution, affects the climate. Global measurements of BC vertical profiles are lacking to support climate change research. To fill this gap, a campaign was conducted over three Italian basin valleys, Terni Valley (Appennines), Po Valley and Passiria Valley (Alps), to characterize the impact of BC on the radiative budget under similar orographic conditions. 120 vertical profiles were measured in winter 2010. The BC vertical profiles, together with aerosol size distribution, aerosol chemistry and meteorological parameters, have been determined using a tethered balloon-based platform equipped with: a micro-Aethalometer AE51 (Magee Scientific), a 1.107 Grimm OPC (0.25-32 μm, 31 size classes), a cascade impactor (Siuotas SKC), and a meteorological station (LSI-Lastem). The aerosol chemical composition was determined from collected PM2.5 samples. The aerosol absorption along the vertical profiles was measured and optical properties calculated using the Mie theory applied to the aerosol size distribution. The aerosol optical properties were validated with AERONET data and then used as inputs to the radiative transfer model libRadtran. Vertical profiles of the aerosol direct radiative effect, the related atmospheric absorption and the heating rate were calculated. Vertical profile measurements revealed some common behaviors over the studied basin valleys. From below the mixing height to above it, a marked concentration drop was found for both BC (from -48.4±5.3% up to -69.1±5.5%) and aerosol number concentration (from -23.9±4.3% up to -46.5±7.3%). These features reflected on the optical properties of the aerosol. Absorption and scattering coefficients decreased from below the MH to above it (babs from -47.6±2.5% up to -71.3±3.0% and bsca from -23.5±0.8% up to -61.2±3.1%, respectively). Consequently, the Single Scattering Albedo increased above the MH (from +4.9±2.2% to +7.4±1.0%). The highest aerosol absorption was

  9. Direct radiative forcing properties of atmospheric aerosols over semi-arid region, Anantapur in India.

    Science.gov (United States)

    Kalluri, Raja Obul Reddy; Gugamsetty, Balakrishnaiah; Kotalo, Rama Gopal; Nagireddy, Siva Kumar Reddy; Tandule, Chakradhar Rao; Thotli, Lokeswara Reddy; Rajuru Ramakrishna, Reddy; Surendranair, Suresh Babu

    2016-10-01

    This paper describes the aerosols optical, physical characteristics and the aerosol radiative forcing pertaining to semi-arid region, Anantapur for the period January 2013-December 2014. Collocated measurements of Aerosol Optical Depth (AOD) and Black Carbon mass concentration (BC) are carried out by using MICROTOPS II and Aethalometer and estimated the aerosol radiative forcing over this location. The mean values of AOD at 500nm are found to be 0.47±0.09, 0.34±0.08, 0.29±0.06 and 0.30±0.07 during summer, winter, monsoon and post-monsoon respectively. The Angstrom exponent (α380-1020) value is observed maximum in March (1.25±0.19) and which indicates the predominance of fine - mode aerosols and lowest in the month of July (0.33±0.14) and may be due to the dominance of coarse-mode aerosols. The diurnal variation of BC is exhibited two height peaks during morning 07:00-08:00 (IST) and evening 19:00-21:00 (IST) hours and one minima noticed during afternoon (13:00-16:00). The highest monthly mean BC concentration is observed in the month of January (3.4±1.2μgm(-3)) and the lowest in July (1.1±0.2μgm(-3)). The estimated Aerosol Direct Radiative Forcing (ADRF) in the atmosphere is found to be +36.8±1.7Wm(-2), +26.9±0.2Wm(-2), +18.0±0.6Wm(-2) and +18.5±3.1Wm(-2) during summer, winter, monsoon and post-monsoon seasons, respectively. Large difference between TOA and BOA forcing is observed during summer which indicate the large absorption of radiant energy (36.80Wm(-2)) which contributes more increase in atmospheric heating by ~1K/day. The BC contribution on an average is found to be 64% and is responsible for aerosol atmospheric heating. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Effects of total integrated solar radiation on radial fruit cracking in tomato [Lycopersicon esculentum] cultivation under rain shelter in cool uplands

    International Nuclear Information System (INIS)

    Suzuki, T.; Yanase, S.; Enya, T.; Shimazu, T.; Tanaka, I.

    2007-01-01

    This study investigated the cause of radial fruit cracking in tomato cultivation under rain shelter in the cool uplands in Gifu Prefecture. The effect of total integrated radiation using two types of training methods was determined over a three-year period. The percentage of refused radial fruit cracking associated with increased total integrated solar radiation from the young fruit stage to the mature green stage. Fruit cracking occurred in the training method which foliage and fruits received a large amount of light-interception. Also, as for fruits that undergo vigorous enlargement, the frequency of the radial fruit cracking increased

  11. Radiation

    International Nuclear Information System (INIS)

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  12. Influence of observed diurnal cycles of aerosol optical depth on aerosol direct radiative effect

    Directory of Open Access Journals (Sweden)

    A. Arola

    2013-08-01

    Full Text Available The diurnal variability of aerosol optical depth (AOD can be significant, depending on location and dominant aerosol type. However, these diurnal cycles have rarely been taken into account in measurement-based estimates of aerosol direct radiative forcing (ADRF or aerosol direct radiative effect (ADRE. The objective of our study was to estimate the influence of diurnal aerosol variability at the top of the atmosphere ADRE estimates. By including all the possible AERONET sites, we wanted to assess the influence on global ADRE estimates. While focusing also in more detail on some selected sites of strongest impact, our goal was to also see the possible impact regionally. We calculated ADRE with different assumptions about the daily AOD variability: taking the observed daily AOD cycle into account and assuming diurnally constant AOD. Moreover, we estimated the corresponding differences in ADREs, if the single AOD value for the daily mean was taken from the the Moderate Resolution Imaging Spectroradiometer (MODIS Terra or Aqua overpass times, instead of accounting for the true observed daily variability. The mean impact of diurnal AOD variability on 24 h ADRE estimates, averaged over all AERONET sites, was rather small and it was relatively small even for the cases when AOD was chosen to correspond to the Terra or Aqua overpass time. This was true on average over all AERONET sites, while clearly there can be much stronger impact in individual sites. Examples of some selected sites demonstrated that the strongest observed AOD variability (the strongest morning afternoon contrast does not typically result in a significant impact on 24 h ADRE. In those cases, the morning and afternoon AOD patterns are opposite and thus the impact on 24 h ADRE, when integrated over all solar zenith angles, is reduced. The most significant effect on daily ADRE was induced by AOD cycles with either maximum or minimum AOD close to local noon. In these cases, the impact on

  13. Neoadjuvant radiation therapy prior to total mesorectal excision for rectal cancer is not associated with postoperative complications using current techniques.

    Science.gov (United States)

    Milgrom, Sarah A; Goodman, Karyn A; Nash, Garrett M; Paty, Philip B; Guillem, José G; Temple, Larissa K; Weiser, Martin R; Garcia-Aguilar, Julio

    2014-07-01

    Neoadjuvant radiation therapy (RT) downstages rectal cancer but may increase postoperative morbidity. This study aims to quantify 30-day complication rates after total mesorectal excision (TME) using current techniques and to assess for an association of these complications with neoadjuvant RT. Stage I-III rectal cancer patients who underwent TME from 2005 to 2010 were identified. Complications occurring within 30 days after TME were retrieved from a prospectively maintained institutional database of postoperative adverse events. The cohort consisted of 461 patients. Median age was 59 years (range 18-90), and 274 patients (59 %) were male. Comorbid conditions included obesity (n = 147; 32 %), coronary artery disease (n = 83; 18 %), diabetes (n = 65; 14 %), and inflammatory bowel disease (n = 19; 4 %). A low anterior resection (LAR) was performed in 383 cases (83 %), an abdominoperineal resection (APR) was performed in 72 cases (16 %), and a Hartmann's procedure was performed in 6 cases (1 %). Preoperative RT was delivered to 310 patients (67 %; median dose of 50.4 Gy, range 27-55.8 Gy). The 30-day incidence of postoperative mortality was 0.4 % (n = 2), any complication 25 % (n = 117), grade 3 or more complication 5 % (n = 24), intra-abdominal infection 3 % (n = 12), abdominal wound complication 9 % (n = 42), perineal wound complication after APR 11 % (n = 8/72), and anastomotic leak after LAR 2 % (n = 6/383). These events were not associated with neoadjuvant RT. In a cohort undergoing TME using current techniques, neoadjuvant RT was not associated with 30-day postoperative morbidity or mortality.

  14. Five-year results of a randomized clinical trial comparing total mastectomy and segmental mastectomy with or without radiation in the treatment of breast cancer

    International Nuclear Information System (INIS)

    Fisher, B.; Bauer, M.; Margolese, R.

    1985-01-01

    In 1976 the authors began a randomized trial to evaluate breast conservation by a segmental mastectomy in the treatment of State I and II breast tumors less than or equal to 4 cm in size. The operation removes only sufficient tissue to ensure that margins of resected specimens are free of tumor. Women were randomly assigned to total mastectomy, segmental mastectomy alone, or segmental mastectomy followed by breast irradiation. All patients had auxillary dissections, and patients with positive nodes received chemotherapy. Life-tables estimates based on data from 1843 women indicated that treatment by segmental mastectomy, with or without breast irradiation, resulted in disease-free, distant-disease-free, and overall survival at five years that was no worse than that after total breast removal. In fact, disease-free survival after segmental mastectomy plus radiation was better than disease-free survival after total mastectomy, and overall survival after segmental mastectomy, with or without radiation, was better than overall survival after total mastectomy. A total of 92.3% of women treated with radiation remained free of breast tumor at five years, as compared with 72.1% of those receiving no radiation. Among patients with positive nodes 97.9% of women treated with radiation and 63.8% of those receiving no radiation remained tumor-free, although both groups received chemotherapy. They conclude that segmental mastectomy, followed by breast irradiation in all patients and adjuvant chemotherapy in women with positive nodes, is appropriate therapy for Stage I and II breast tumors less than or equal to 4 cm, provided that margins of resected specimens are free of tumor. 23 references, 4 figures, 6 tables

  15. Extinction of direct solar radiation in Puławy in the years 1969–1989

    International Nuclear Information System (INIS)

    Uscka-Kowalkowska, J.

    2007-01-01

    The paper presents the problem of attenuation of the direct solar radiation in Puławy in the years 1969–1989. The extinction was expressed with the help of the Linke’s turbidity factor counted on the basis of measurements of the direct solar irradiance at the Institute of Soil Science and Plant Cultivation in the years 1969–1989. The turbidity factor was counted and reduced to 2 optical mass of the atmosphere according to the method proposed by Grenier et al. (6). The mean value of the turbidity factor for the atmosphere in the study period was in the class of raised turbidity and equalled 3.41. However, an improvement was noted in the optical conditions of the atmosphere expressed by the decrease of the value of Linke’s turbidity factor during the whole study period. The annual course of the turbidity is typical, i.e. it increases in the warm half-year and decreases in the cold half-year. In the daily course, the mean turbidity of the atmosphere increases with the altitude of the Sun above the horizon. The atmospheric turbidity also depends on the kind of the air masses present. During the study period in Puławy, the lowest value of the atmospheric turbidity occurred in the case of arctic air masses (2.79), while the highest in tropical air (4.05). Polar-continental and polar-maritime air masses are characterised by similar turbidity level of the atmosphere, 3.44 and 3.50, respectively. (author) [pl

  16. Directional radiative transfer by SCOPE, SLC and DART using laser scan derived structural forest parameters

    Science.gov (United States)

    Timmermans, Joris; Gastellu-Etchegorry, Jean Philippe; van der Tol, Christiaan; Verhoef, Wout; Vekerdy, Zoltan; Su, Zhongbo

    2017-04-01

    Accurate estimation of the radiative transfer (RT) over vegetation is the corner stone of agricultural and hydrological remote sensing applications. Present remote sensing sensors mostly use traditional optical, thermal and microwave observations. However with these traditional observations characterization of the light efficiency and photosynthetic rate can only be accomplished indirectly. A promising new method of observing these processes is by using the fluorescent emitted radiation. This approach was recently highlighted due to the selection of the FLEX sensor as a future Earth Explorer by the European Space agency (ESA). Several modelling activities have been undertaken to better understand the technical feasibilities of this sensor. Within these studies, the SCOPE model has been chosen as the baseline algorithm. This model combines a detailed RT description of the canopy, using a discrete version of the SAIL model, with a description of photosynthetic processes (by use of the Farquhar/Ball-Berry model). Consequently, this model is capable of simulating simultaneously the biophysical processes and jointly the fluorescent, optical and thermal RT. The SAIL model however is a 1D RT model and consequently provides higher uncertainties with increasing vegetation structures. The main objective of this research is to investigate the limitations of the RT model component of the SCOPE model over complex canopies. In particular the aim of this research is to evaluate the validity for increasingly structural complex canopies', on the bidirectional reflectance distribution functions (BRDF) of these canopies. This was accomplished by evaluating the simulated outgoing radiation from SCOPE/SAIL against simulations of the DART 3D RT model. In total nine different scenarios were simulated with the DART RTM with increasing structural complexity, ranging from the simple 'Plot' scenario to the highly complex 'Multiple Crown' scenario. The canopy parameters are retrieved from a

  17. Direct evidence for radiative charge transfer after inner-shell excitation and ionization of large clusters

    Science.gov (United States)

    Hans, Andreas; Stumpf, Vasili; Holzapfel, Xaver; Wiegandt, Florian; Schmidt, Philipp; Ozga, Christian; Reiß, Philipp; Ben Ltaief, Ltaief; Küstner-Wetekam, Catmarna; Jahnke, Till; Ehresmann, Arno; Demekhin, Philipp V.; Gokhberg, Kirill; Knie, André

    2018-01-01

    We directly observe radiative charge transfer (RCT) in Ne clusters by dispersed vacuum-ultraviolet photon detection. The doubly ionized Ne2+-{{{N}}{{e}}}n-1 initial states of RCT are populated after resonant 1s-3p photoexcitation or 1s photoionization of Ne n clusters with ≈ 2800. These states relax further producing Ne+-Ne+-{{{N}}{{e}}}n-2 final states, and the RCT photon is emitted. Ab initio calculations assign the observed RCT signal to the{}{{{N}}{{e}}}2+(2{{{p}}}-2{[}1{{D}}]){--}{{{N}}{{e}}}n-1 initial state, while transitions from other possible initial states are proposed to be quenched by competing relaxation processes. The present results are in agreement with the commonly discussed scenario, where the doubly ionized atom in a noble gas cluster forms a dimer which dissipates its vibrational energy on a picosecond timescale. Our study complements the picture of the RCT process in weakly bound clusters, providing information which is inaccessible by charged particle detection techniques.

  18. Automation of the solution type of intensity modulated radiation therapy with direct planning neoplastic breast lesions

    International Nuclear Information System (INIS)

    Fuente Rosales, Liset De La; Larrinaga Cortina, Eduardo Francisco

    2009-01-01

    Breast cancer ranks first among the lesions malignancies involving the Cuban women and the second in mortality only surpassed by lung injury. The breast-conserving surgery is becoming less appeal, with an increase in the choice of radiotherapy to the breast operated, and the surgical bed. Intensity Modulated Radiation Therapy, IMRT has demonstrated better results in the dose distribution for irradiation dimensional treatment breast shaping, 3DCRT. We developed a MATLAB application to obtain the solution type to direct planning IMRT for breast neoplasm. The technique was implemented in the Planning System Treatment Plus Theraplan v3.8 and Precise1 ELEKTA linear accelerator. Static segments are constructed for each portal of incidence and Excel files are exported as the positions of the blades. The technique was validated with a patient, which he performed a radiographic study of computerized axial tomography planning purposes. The standard solution built is consistent with those reported internationally and consists of a segment type and at least two segments of type B. The assignment of the relative weights of the segments is done manually by trial and error procedure, with the general rule of 90% by weight assigned to segment A and the remaining 10% divided equally between B-type segments IMRT breast obtained in a dose 17% homogeneity better than 3DCRT and reduced the average dose in the lung ipsilateral 15%. (author)

  19. Definition of medical event is to be based on the total source strength for evaluation of permanent prostate brachytherapy: A report from the American Society for Radiation Oncology.

    Science.gov (United States)

    Nag, Subir; Demanes, D Jeffrey; Hagan, Michael; Rivard, Mark J; Thomadsen, Bruce R; Welsh, James S; Williamson, Jeffrey F

    2011-10-01

    The Nuclear Regulatory Commission deems it to be a medical event (ME) if the total dose delivered differs from the prescribed dose by 20% or more. A dose-based definition of ME is not appropriate for permanent prostate brachytherapy as it generates too many spurious MEs and thereby creates unnecessary apprehension in patients, and ties up regulatory bodies and the licensees in unnecessary and burdensome investigations. A more suitable definition of ME is required for permanent prostate brachytherapy. The American Society for Radiation Oncology (ASTRO) formed a working group of experienced clinicians to review the literature, assess the validity of current regulations, and make specific recommendations about the definition of an ME in permanent prostate brachytherapy. The working group found that the current definition of ME in §35.3045 as "the total dose delivered differs from the prescribed dose by 20 percent or more" was not suitable for permanent prostate brachytherapy since the prostate volume (and hence the resultant calculated prostate dose) is dependent on the timing of the imaging, the imaging modality used, the observer variability in prostate contouring, the planning margins used, inadequacies of brachytherapy treatment planning systems to calculate tissue doses, and seed migration within and outside the prostate. If a dose-based definition for permanent implants is applied strictly, many properly executed implants would be improperly classified as an ME leading to a detrimental effect on brachytherapy. The working group found that a source strength-based criterion, of >20% of source strength prescribed in the post-procedure written directive being implanted outside the planning target volume is more appropriate for defining ME in permanent prostate brachytherapy. ASTRO recommends that the definition of ME for permanent prostate brachytherapy should not be dose based but should be based upon the source strength (air-kerma strength) administered.

  20. Radiation treatment compliance in the indigenous population: the pilot of Northern Territory experience and future directions

    International Nuclear Information System (INIS)

    Le, Hien; Carruthers, Scott; Penniment, Michael; Roos, Daniel; Sullivan, Thomas; Baxi, Siddhartha

    2013-01-01

    There is a perception that Indigenous patients are less likely to attend radiotherapy treatment. This study sought to determine if a difference in radiotherapy treatment compliance rates exists between Indigenous and non-Indigenous patients. Secondly, we aimed to ascertain which patient, disease and treatment factors affect compliance in Indigenous patients. All patients treated with radiotherapy at the Alan Walker Cancer Care Centre between March and October 2010 were analysed. Data regarding compliance rates (defined as those who chose and completed the recommended course of treatment), patient, disease and treatment factors were collected, and chi-squared and Fisher's exact tests were applied. A total of 41 courses were delivered to Indigenous patients and 224 courses delivered to non-Indigenous patients in this period. There was no difference in compliance between Indigenous and non-Indigenous patients (83% vs. 81%, P=0.75). Of the factors assessed, it was found that there was an association between toxicity grade and compliance (P=0.048). From this cohort, we cannot support the perception that Indigenous patients have overall poorer compliance with recommended radiation treatment courses. In this study, the only factor which correlated significantly with compliance was toxicity grade. It is felt that a number of factors, which negatively impact on compliance, can potentially be counteracted by a culturally sensitive model of care.

  1. European ErP Directive. Total condensing technology: the solution for heating and DHW units in the hotel sector

    International Nuclear Information System (INIS)

    Martín, G.

    2016-01-01

    Since 26 September 2015, the Ecodesign ErP Directive has been of compulsory application for EU Member States as regards the design of Energy-related Products (ErP) and as from its entry into force only those products manufactured according to the ErP requirements can be sold with the EC label. Although this directive affects over 1,000 product categories, for those relating to HVAC and DHW production, it covers boilers, heat pumps, accumulators, cogeneration systems, combined products systems, establishing their minimum efficiency levels, the maximum levels of NOX emissions, the minimum insulation for accumulators and the maximum level of acoustic emissions for heat pumps. (Author)

  2. Effects of radiation and α-tocopherol on saliva flow rate, amylase activity, total protein and electrolyte levels in oral cavity cancer

    Directory of Open Access Journals (Sweden)

    Chitra S

    2008-01-01

    Full Text Available Objective: The objective of the present study was to evaluate early and late effects of radiation and a-tocopherol on the secretion rate of saliva and on selected saliva salivary parameters in oral cavity cancer patients. Patients & Methods: Eighty-nine histologically confirmed oral cavity cancer patients (OCC were enrolled in the study. Resting whole saliva was collected before, during and at the end of the radiation therapy (RT and simultaneous supplementation with α - tocopherol to the radiation treated patients (RT + AT. Results: Salivary flow rate, pH, amylase activity, total protein, sodium and potassium were analyzed. Increased pH, potassium and decreased flow rate, amylase activity, protein content and sodium were observed in 6 weeks of radiation treated patients when compared to OCC patients. A significant improvement of those parameters was observed on α - tocopherol supplementation in RT + AT patients. Conclusion: Supplementation with α - tocopherol improves the salivary flow rate thereby, maintains salivary parameters.

  3. Acetone Enhances the Direct Analysis of Total Condensed Tannins in Forage Legumes by the Butanol-HCl Assay

    Science.gov (United States)

    Depending on concentration, condensed tannins (CT) in forages have no effect, enhance, or impede protein utilization and performance of ruminants. Defining optimal forage CT levels has been elusive, partly because current methods for estimating total soluble plus insoluble CT are laborious or inaccu...

  4. Increased mitochondrial mass in cells with functionally compromised mitochondria after exposure to both direct gamma radiation and bystander factors.

    LENUS (Irish Health Repository)

    Nugent, Sharon M E

    2007-07-01

    The bystander effect describes radiation-like damage in unirradiated cells either in the vicinity of irradiated cells or exposed to medium from irradiated cells. This study aimed to further characterize the poorly understood mitochondrial response to both direct irradiation and bystander factor(s) in human keratinocytes (HPV-G) and Chinese hamster ovarian cells (CHO-K1). Oxygen consumption rates were determined during periods of state 4, state 3 and uncoupled respiration. Mitochondrial mass was determined using MitoTracker FM. CHO-K1 cells showed significantly reduced oxygen consumption rates 4 h after exposure to 5 Gy direct radiation and irradiated cell conditioned medium (ICCM) and an apparent recovery 12-24 h later. The apparent recovery was likely due to the substantial increase in mitochondrial mass observed in these cells as soon as 4 h after exposure. HPV-G cells, on the other hand, showed a sustained increase in oxygen consumption rates after ICCM exposure and a transient increase 4 h after exposure to 5 Gy direct radiation. A significant increase in mitochondrial mass per HPV-G cell was observed after exposure to both direct radiation and ICCM. These findings are indicative of a stress response to mitochondrial dysfunction that increases the number of mitochondria per cell.

  5. Long-term total solar radiation variability at the Polish Baltic coast in Kołobrzeg within the period 1964-2013

    Czech Academy of Sciences Publication Activity Database

    Kleniewska, M.; Chojnicki, B. H.; Acosta, Manuel

    2016-01-01

    Roč. 4, č. 2 (2016), s. 35-40 ISSN 2299-3835 R&D Projects: GA MŠk(CZ) LO1415 Institutional support: RVO:67179843 Keywords : total solar radiation * Kołobrzeg * dimming * brightening Subject RIV: EH - Ecology, Behaviour

  6. Comparison of ultraviolet Bi-directional Reflectance Distribution Function (BRDF) measurements of diffusers used in the calibration of the Total Ozone Mapping Spectrometer (TOMS)

    OpenAIRE

    Butler, J.J.; Park, H.; Barnes, P.Y.; Early, E.A.; Eijk-Olij, C. van; Zoutman, A.E.; Buller-Leeuwen, S. van; Groote Schaarsberg, J.

    2002-01-01

    The measurement and long-term monitoring of global total ozone by ultraviolet albedo measuring satellite instruments require accurate and precise determination of the Bi-directional Reflectance Distribution Function (BRDF) of laboratory-based diffusers used in the pre-launch calibration of those instruments. To assess the ability of laboratories to provide accurate Ultra Violet (UV) diffuse BRDF measurements, a BRDF measurement comparison was initiated by the NASA Total Ozone Mapping Spectrom...

  7. Direct radiative effects by anthropogenic particles at a polluted site: Rome (Italy)

    International Nuclear Information System (INIS)

    Bergamo, A.; De Tomasi, F.; Perrone, M.R.

    2008-01-01

    The direct radiative effect (DRE) by all (anthropogenic plus natural) and anthropogenic aerosols is calculated at the solar (0.34 μm) and infrared (4-200 μm) spectral range to better address the annual cycle of the anthropogenic aerosols impact at a site (Rome, Italy) significantly affected by pollution. Aerosol optical and microphysical properties from 2003 AERONET Sun/sky-photometer measurements and solar albedos based on MODIS satellite sensor data constitute the necessary input to radiative transfer simulations. Clear- and all-sky conditions are investigated by adopting ISCCP monthly products for high-, mid-and low-cloud cover. It is shown that monthly mean values of aerosol optical depths by anthropogenic particles (AOD a ) are on average more than 50% of the corresponding all-aerosol-optical-depth (AOD) monthly means. In particular, the AOD a /AOD ratio that varies within the (0.51-0.83) on autumn-winter (A W, October-March), varies within the (0.50-0.71 range on spring-summer (S S, April-September) as a consequence of the larger contribution of natural particles on S S. The surface (sfc), all-sky DRE by anthropogenic particles that is negative all year round at solar wave-lengths, represents on average 60% and 51% of the all-sky sfc-DRE by all aerosols on A W and S S, respectively. The all-sky atmospheric forcing by anthropogenic particles (AF a ) that is positive all year round, is little dependent on seasons: it varies within the (1.0-4.1) W/m 2 and (2.0-4.2) W/m 2 range an A W and S S, respectively. Conversely, the all-sky A F by all aerosols is characterized by a marked seasonality. As a consequence, the atmospheric forcing by anthropogenic particles that on average is 50% of the A F value on A W, decreases down to 36% of the A F value on S S. Infrared aerosols DREs that are positive all year round are significantly smaller than the corresponding absolute values of solar DREs. Clouds decrease on average ToA- and sfc-DRE absolute values by anthropogenic

  8. Improvement of the radiation protection in medicine by implementation of the Council Directive 97/43/EURATOM

    International Nuclear Information System (INIS)

    Milu, C.; Dumitrescu, A.

    2005-01-01

    The European Council Directive No. 97/43/EURATOM was approved on 30 June 1997 and refers to health protection of individuals against the damages of ionising radiation in relation to medical exposure, superseding the Directive 84/466/EURATOM. As in most European countries, medical exposure is the main man-made radiation exposure of population. Of particular concern in radiation protection in medicine is the use of X-rays for diagnostic purposes, involving potential radiation exposure of young population and of pregnant women. The 97/43/EURATOM Directive is now fully adopted into Romanian legislation and a plan for its implementation has been established. Several practical issues have already arisen and they are related to (1) justification of individual medical exposure (patient selection) due to unclear distribution of responsibilities between the prescriber and the practitioner; (2) justification of medical exposures with no direct health benefit for the exposed person (reconsideration of health screening programmes, exposure of individuals as part of medico-legal procedures); (3) patient dosimetry and the use of Diagnostic Reference Levels (need of procedures and equipment); (4) QA/QC (procedure, training and test facilities); (5) examination of biomedical and medical research by an ethics committee; (6) application of Dose Constraints and Clinical Audit concepts; (7) prohibition of fluoroscopy examinations without an image intensification. An intensive training programme of the personnel involved (practitioners, inspection) was started and special efforts for the acquisition of appropriate equipment are made with the aim to improve radiation protection in medicine, through the implementation of the EU Directive.(author)

  9. The use of a miniature direct-reading solid state radiation dosimeter to measure the radiation dose from technetium-99m to the bladder wall of the pig

    International Nuclear Information System (INIS)

    McLean, J.R.N.; Frappier, G.; Thomson, I.; Shortt, K.

    1992-01-01

    Each year about one million Canadians receive Tc-99m-labeled radiopharmaceuticals for diagnostic purposes. Many of these radioactive agents or their metabolites are excreted in the urine. Consequently, the bladder wall can receive a relatively high radiation dose and is often considered one of the organs at risk. The bladder contents could also contribute a significant dose to a developing fetus. The risk associated with the use of any radiopharmaceutical is determined by the sum of radiation doses to selected organs weighted with an appropriate factor for each organ's radiosensitivity. To ensure that a risk estimate is realistic, it is essential to compare the estimate of radiation dose generated by a mathematical model to results obtained by direct physical measurement. In this project, real-time measurements of dose and dose rate to the bladder wall from intravenous technetium-99m were obtained by direct physical measurement using a miniature solid state radiation dosimeter implanted onto the bladder wall of a laboratory pig. The measured value is compared to the calculated dose estimate. Two methods of data logging are described. tab., 2 refs., 4 figs

  10. Direct radiative forcing properties of atmospheric aerosols over semi-arid region, Anantapur in India

    Energy Technology Data Exchange (ETDEWEB)

    Kalluri, Raja Obul Reddy; Gugamsetty, Balakrishnaiah [Aerosol & Atmospheric Research Laboratory, Department of Physics, Sri Krishnadevaraya University, Anantapur 515 003, Andhra Pradesh (India); Kotalo, Rama Gopal, E-mail: krgverma@yahoo.com [Aerosol & Atmospheric Research Laboratory, Department of Physics, Sri Krishnadevaraya University, Anantapur 515 003, Andhra Pradesh (India); Nagireddy, Siva Kumar Reddy; Tandule, Chakradhar Rao; Thotli, Lokeswara Reddy [Aerosol & Atmospheric Research Laboratory, Department of Physics, Sri Krishnadevaraya University, Anantapur 515 003, Andhra Pradesh (India); Rajuru Ramakrishna, Reddy [Aerosol & Atmospheric Research Laboratory, Department of Physics, Sri Krishnadevaraya University, Anantapur 515 003, Andhra Pradesh (India); Srinivasa Ramanujan Institute of Technology, B.K. Samudram Mandal, Anantapur 515 701, Andhra Pradesh (India); Surendranair, Suresh Babu [Space Physics Laboratory, Vikram Sarabhai Space Centre, Trivandrum 695 022, Kerala (India)

    2016-10-01

    This paper describes the aerosols optical, physical characteristics and the aerosol radiative forcing pertaining to semi-arid region, Anantapur for the period January 2013-December 2014. Collocated measurements of Aerosol Optical Depth (AOD) and Black Carbon mass concentration (BC) are carried out by using MICROTOPS II and Aethalometer and estimated the aerosol radiative forcing over this location. The mean values of AOD at 500 nm are found to be 0.47 ± 0.09, 0.34 ± 0.08, 0.29 ± 0.06 and 0.30 ± 0.07 during summer, winter, monsoon and post-monsoon respectively. The Angstrom exponent (α{sub 380–1020}) value is observed maximum in March (1.25 ± 0.19) and which indicates the predominance of fine - mode aerosols and lowest in the month of July (0.33 ± 0.14) and may be due to the dominance of coarse-mode aerosols. The diurnal variation of BC is exhibited two height peaks during morning 07:00–08:00 (IST) and evening 19:00–21:00 (IST) hours and one minima noticed during afternoon (13:00–16:00). The highest monthly mean BC concentration is observed in the month of January (3.4 ± 1.2 μg m{sup −3}) and the lowest in July (1.1 ± 0.2 μg m{sup −3}). The estimated Aerosol Direct Radiative Forcing (ADRF) in the atmosphere is found to be + 36.8 ± 1.7 W m{sup −2}, + 26.9 ± 0.2 W m{sup −2}, + 18.0 ± 0.6 W m{sup −2} and + 18.5 ± 3.1 W m{sup −2} during summer, winter, monsoon and post-monsoon seasons, respectively. Large difference between TOA and BOA forcing is observed during summer which indicate the large absorption of radiant energy (36.80 W m{sup −2}) which contributes more increase in atmospheric heating by ~ 1 K/day. The BC contribution on an average is found to be 64% and is responsible for aerosol atmospheric heating. - Highlights: • The mean values of AOD{sub 500} are found to be high during summer whereas low in monsoon. • The highest values of BC are observed in January and the lowest in the month of July. • The annual mean

  11. Direct radiative forcing properties of atmospheric aerosols over semi-arid region, Anantapur in India

    International Nuclear Information System (INIS)

    Kalluri, Raja Obul Reddy; Gugamsetty, Balakrishnaiah; Kotalo, Rama Gopal; Nagireddy, Siva Kumar Reddy; Tandule, Chakradhar Rao; Thotli, Lokeswara Reddy; Rajuru Ramakrishna, Reddy; Surendranair, Suresh Babu

    2016-01-01

    This paper describes the aerosols optical, physical characteristics and the aerosol radiative forcing pertaining to semi-arid region, Anantapur for the period January 2013-December 2014. Collocated measurements of Aerosol Optical Depth (AOD) and Black Carbon mass concentration (BC) are carried out by using MICROTOPS II and Aethalometer and estimated the aerosol radiative forcing over this location. The mean values of AOD at 500 nm are found to be 0.47 ± 0.09, 0.34 ± 0.08, 0.29 ± 0.06 and 0.30 ± 0.07 during summer, winter, monsoon and post-monsoon respectively. The Angstrom exponent (α_3_8_0_–_1_0_2_0) value is observed maximum in March (1.25 ± 0.19) and which indicates the predominance of fine - mode aerosols and lowest in the month of July (0.33 ± 0.14) and may be due to the dominance of coarse-mode aerosols. The diurnal variation of BC is exhibited two height peaks during morning 07:00–08:00 (IST) and evening 19:00–21:00 (IST) hours and one minima noticed during afternoon (13:00–16:00). The highest monthly mean BC concentration is observed in the month of January (3.4 ± 1.2 μg m"−"3) and the lowest in July (1.1 ± 0.2 μg m"−"3). The estimated Aerosol Direct Radiative Forcing (ADRF) in the atmosphere is found to be + 36.8 ± 1.7 W m"−"2, + 26.9 ± 0.2 W m"−"2, + 18.0 ± 0.6 W m"−"2 and + 18.5 ± 3.1 W m"−"2 during summer, winter, monsoon and post-monsoon seasons, respectively. Large difference between TOA and BOA forcing is observed during summer which indicate the large absorption of radiant energy (36.80 W m"−"2) which contributes more increase in atmospheric heating by ~ 1 K/day. The BC contribution on an average is found to be 64% and is responsible for aerosol atmospheric heating. - Highlights: • The mean values of AOD_5_0_0 are found to be high during summer whereas low in monsoon. • The highest values of BC are observed in January and the lowest in the month of July. • The annual mean atmospheric forcing is found to be

  12. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    Energy Technology Data Exchange (ETDEWEB)

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R. [Water Studies Centre, School of Chemistry, Monash University, Victoria 3800 (Australia); McKelvie, Ian D., E-mail: iandm@unimelb.edu.au [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2011-10-17

    Highlights: {yields} Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. {yields} A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. {yields} Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. {yields} Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. {yields} This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L{sup -1}, 0.4%RSD (1 mg N L{sup -1} as nitrate, n = 10), a coefficient of determination (R{sup 2}) of 0.9995 over the calibration range 0.0-2.0 mg N L{sup -1}, and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L{sup -1}, 1%RSD (1 mg N L{sup -1} as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L{sup -1}, and a throughput of 5 sample h{sup -1} measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column

  13. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    International Nuclear Information System (INIS)

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R.; McKelvie, Ian D.

    2011-01-01

    Highlights: → Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. → A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. → Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. → Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. → This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L -1 , 0.4%RSD (1 mg N L -1 as nitrate, n = 10), a coefficient of determination (R 2 ) of 0.9995 over the calibration range 0.0-2.0 mg N L -1 , and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L -1 , 1%RSD (1 mg N L -1 as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L -1 , and a throughput of 5 sample h -1 measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column. The overlap of chloride and nitrate spectra in seawater is

  14. Solar radiation and cooling load calculation for radiant systems: Definition and evaluation of the Direct Solar Load

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2010-01-01

    The study of the influence of solar radiation on the built environment is a basic issue in building physics and currently it is extremely important because glazed envelopes are widely used in contemporary architecture. In the present study, the removal of solar heat gains by radiant cooling systems...... is investigated. Particular attention is given to the portion of solar radiation converted to cooling load, without taking part in thermal absorption phenomena due to the thermal mass of the room. This specific component of the cooling load is defined as the Direct Solar Load. A simplified procedure to correctly...... calculate the magnitude of the Direct Solar Load in cooling load calculations is proposed and it is implemented with the Heat Balance method and the Radiant Time Series method. The F ratio of the solar heat gains directly converted to cooling load, in the case of a low thermal mass radiant ceiling...

  15. Global direct radiative forcing by process-parameterized aerosol optical properties

    Science.gov (United States)

    KirkevâG, Alf; Iversen, Trond

    2002-10-01

    A parameterization of aerosol optical parameters is developed and implemented in an extended version of the community climate model version 3.2 (CCM3) of the U.S. National Center for Atmospheric Research. Direct radiative forcing (DRF) by monthly averaged calculated concentrations of non-sea-salt sulfate and black carbon (BC) is estimated. Inputs are production-specific BC and sulfate from [2002] and background aerosol size distribution and composition. The scheme interpolates between tabulated values to obtain the aerosol single scattering albedo, asymmetry factor, extinction coefficient, and specific extinction coefficient. The tables are constructed by full calculations of optical properties for an array of aerosol input values, for which size-distributed aerosol properties are estimated from theory for condensation and Brownian coagulation, assumed distribution of cloud-droplet residuals from aqueous phase oxidation, and prescribed properties of the background aerosols. Humidity swelling is estimated from the Köhler equation, and Mie calculations finally yield spectrally resolved aerosol optical parameters for 13 solar bands. The scheme is shown to give excellent agreement with nonparameterized DRF calculations for a wide range of situations. Using IPCC emission scenarios for the years 2000 and 2100, calculations with an atmospheric global cliamte model (AFCM) yield a global net anthropogenic DRF of -0.11 and 0.11 W m-2, respectively, when 90% of BC from biomass burning is assumed anthropogenic. In the 2000 scenario, the individual DRF due to sulfate and BC has separately been estimated to -0.29 and 0.19 W m-2, respectively. Our estimates of DRF by BC per BC mass burden are lower than earlier published estimates. Some sensitivity tests are included to investigate to what extent uncertain assumptions may influence these results.

  16. Near ultraviolet radiation (280-400 nm): Direct and indirect effects on microbial pathogens

    International Nuclear Information System (INIS)

    Asthana, A.

    1993-01-01

    Responses of pigmented pathogenic fungi and E. coli strains differing in DNA repair and catalase proficiency to direct and indirect effects of ultraviolet radiation were evaluated. Pigments in the four fungal pathogens of Citrus differed in their ability to protect against direct UV and damage by UV-A -mediated phototoxins of both host and non-host origin. UV-A and UV-B did not inactivate the fungal species. Differential protection in wild type strains of the two Fusarium spp. and in the wild type strains of the two Penicilium spp. against UV-C was observed. Wild type and mutants with altered coloration in Penicilium spp. protected to varying extent against both α-T and 8-MOP in the presence of UV-A. UV-B irradiation of E. coli resulted in inactivation of strains deficient in DNA excision repair. Plasmid DNA damaged in vitro by UV-B from lamp systems as well as by sunlight, and transformed in vivo into bacterial cells lacking specific nucleases showed reduced transformation in DNA excision repair strains. UV-B enriched wavelengths isolated from a solar simulator affected plasmid DNA in a similar manner as UV-B from lamp systems. Sunlight, however affected the membrane of whole cells. Concentration of foliar furanocoumarins of Citrus jambhiri decreased with UV-B irradiation. Phototoxicity to Fusarium spp. was accounted for, in part, by furanocoumarins, psoralen and bergapten (5-MOP) and others. Pure psoralen and 5-MOP affected both Fusarium spp. similarly and carotenoids protected only partially in the wild type strains. Citrus targetted the cell membrane in Fusarium spp.l and in E. coli strains; carotenoids in both of which protected against such damage. Loss in structural integrity of plasmid DNA when treated with citral and UV-A correlated with loss in transforming activity. Biological damage to membrane and DNA was due to the production of hydrogen peroxide. Fruit-rot pathogens Penicilium spp. were not affected by either furanocoumarins or citrals

  17. Radium-based estimates of cesium isotope transport and total direct ocean discharges from the Fukushima Nuclear Power Plant accident

    Energy Technology Data Exchange (ETDEWEB)

    Charette, M.A.; Breier, C.F.; Henderson, P.B.; Pike, S.M.; Buesseler, K.O. [Woods Hole Oceanographic Institution, Woods Hole, MA (United States). Dept. of Marine Chemistry and Geochemistry; Rypina, I.I.; Jayne, S.R. [Woods Hole Oceanographic Institution, Woods Hole, MA (United States). Dept. of Physical Oceanography

    2013-07-01

    Radium has four naturally occurring isotopes that have proven useful in constraining water mass source, age, and mixing rates in the coastal and open ocean. In this study, we used radium isotopes to determine the fate and flux of runoff-derived cesium from the Fukushima Dai-ichi Nuclear Power Plant (FNPP). During a June 2011 cruise, the highest cesium (Cs) concentrations were found along the eastern shelf of northern Japan, from Fukushima south, to the edge of the Kuroshio Current, and in an eddy ∝ 130 km from the FNPP site. Locations with the highest cesium also had some of the highest radium activities, suggesting much of the direct ocean discharges of Cs remained in the coastal zone 2-3 months after the accident. We used a short-lived Ra isotope ({sup 223}Ra, t{sub 1/2} = 11.4 d) to derive an average water mass age (T{sub r}) in the coastal zone of 32 days. To ground-truth the Ra age model, we conducted a direct, station-by-station comparison of water mass ages with a numerical oceanographic model and found them to be in excellent agreement (model avg. T{sub r} = 27 days). From these independent T{sub r} values and the inventory of Cs within the water column at the time of our cruise, we were able to calculate an offshore {sup 134}Cs flux of 3.9-4.6 x 10{sup 13} Bq d{sup -1}. Radium-228 (t{sub 1/2} = 5.75 yr) was used to derive a vertical eddy diffusivity (K{sub z}) of 0.7 m{sup 2} d{sup -1} (0.1 cm{sup 2} s{sup -1}); from this K{sub z} and {sup 134}Cs inventory, we estimated a {sup 134}Cs flux across the pycnocline of 1.8 x 10{sup 4} Bq d{sup -1} for the same time period. On average, our results show that horizontal mixing loss of Cs from the coastal zone was ∝ 10{sup 9} greater than vertical exchange below the surface mixed layer. Finally, a mixing/dilution model that utilized our Ra-based and oceanographic model water mass ages produced a direct ocean discharge of {sup 134}Cs from the FNPP of 11-16 PBq at the time of the peak release in early April 2011

  18. Lower radiation burden in state of the art fluoroscopic cystography compared to direct isotope cystography in children.

    Science.gov (United States)

    Haid, Bernhard; Becker, Tanja; Koen, Mark; Berger, Christoph; Langsteger, Werner; Gruy, Bernhard; Putz, Ernst; Haid, Stephanie; Oswald, Josef

    2015-02-01

    Both, fluoroscopic voiding cystourethrography (fVCUG) and direct isotope cystography (DIC) are diagnostic tools commonly used in pediatric urology. Both methods can detect vesicoureteral reflux (VUR) with a high sensitivity. Whilst the possibility to depict anatomical details and important structures as for instance the urethra in boys or the detailed calyceal anatomy are advantages of fVCUG, a lower radiation burden is thought to be the main advantage of DIC. In the last decade, however, a rapid technical evolution has occurred in fluoroscopy by implementing digital grid-controlled, variable rate, pulsed acquisition technique. As documented in literature this led to a substantial decrease in radiation burden conferred during fVCUGs. To question the common belief that direct isotope cystography confers less radiation burden compared to state of the art fluoroscopic voiding cystography. Radiation burden of direct isotope cystography in 92 children and in additional 7 children after an adaption of protocol was compared to radiation burden of fluoroscopic voiding cystourethrography in 51. The examinations were performed according to institutional protocols. For calculation of mean effective radiation dose [mSv] for either method published physical models correcting for age and sex were used. For DIC the model published by Stabin et al., 1998 was applied, for fVCUG two different physical models were used (Schultz et al., 1999, Lee et al., 2009). The radiation burden conferred by direct isotope cystography was significantly higher as for fluoroscopic voiding cystourethrography. The mean effective radiation dose for direct isotope cystography accounted to 0.23 mSv (± 0.34 m, median 0.085 mSv) compared to 0.015 mSv (± 0.013, median 0.008 mSv, model by Schultz et al.) - 0.024 mSv (± 0.018, median 0.018 mSv, model by Lee et al.) for fluoroscopic voiding cystourethrography. After a protocol adaption to correct for a longer examination time in DIC that was caused by

  19. Comparison of ultraviolet Bi-directional Reflectance Distribution Function (BRDF) measurements of diffusers used in the calibration of the Total Ozone Mapping Spectrometer (TOMS)

    NARCIS (Netherlands)

    Butler, J.J.; Park, H.; Barnes, P.Y.; Early, E.A.; Eijk-Olij, C. van; Zoutman, A.E.; Buller-Leeuwen, S. van; Groote Schaarsberg, J.

    2002-01-01

    The measurement and long-term monitoring of global total ozone by ultraviolet albedo measuring satellite instruments require accurate and precise determination of the Bi-directional Reflectance Distribution Function (BRDF) of laboratory-based diffusers used in the pre-launch calibration of those

  20. Diurnal cycle of the dust instantaneous direct radiative forcing over the Arabian Peninsula

    KAUST Repository

    Osipov, Sergey; Stenchikov, Georgiy L.; Brindley, H.; Banks, J.

    2015-01-01

    In this study we attempted to better quantify radiative effects of dust over the Arabian Peninsula and their dependence on input parameters. For this purpose we have developed a stand-alone column radiation transport model coupled with the Mie, T

  1. Effect of cross-linkage by gamma radiation in heavy doses to low wear polyethylene in total hip prostheses

    International Nuclear Information System (INIS)

    Oonishi, H.

    1996-01-01

    Wear, frictional torque and creep deformity of UHMWPE sockets crosslinked by gamma radiation of 100, 500 and 1000 Mrad in combination with 28 mm alumina heads, were measured using a hip simulator (under constant load 250 kgf with lubrication of saline solution). Hardness and hydrophilic increased and creep deformity decreased as a result of gamma radiation. The initial wear (decrement of the thickness) of the socket with radiation of 0, 100, 500 and 1000 Mrad was, 150 μm, 100 μm, 70 μm and 50 μm, respectively. The time to steady-state wear at 0, 100, 5000 and 1000 Mrad was about 0.15 million, 0.15 million, 0.1 million, and 0.05 million cycles, respectively. The steady-state wear (decrement of the thickness) of the socket without and with radiation was 200 μm/million cycles and less than 20 μm/million cycles, respectively. Rotational torque was under 0.65 Nm in every case. Swing frictional torque at radiation levels of 0, 100, 500 and 1000 MRad were 1.60-2.84 Nm, 3.24-9.02 Nm, 5.23-8.78 Nm, and 2.51-6.79 Nm, respectively. (Author)

  2. Physicochemical characterization, antioxidant activity and total phenolic content in 'Gala' apples subjected to different UV-C radiation doses

    Directory of Open Access Journals (Sweden)

    Thaís Gabrielle Dias

    2017-01-01

    Full Text Available UV-C radiation is a food preservation method aimed to extend the life of the product, inactivate microorganisms, and stimulate the synthesis of phenolic compounds. This study aimed to physicochemically characterize and evaluate the antioxidant activity and phenolic content of ‘Gala’ apples subjected to different UV-C radiation doses.The fruits were harvested, sanitized, selected and inserted into a UV-C radiation chamber, and different radiation doses were applied as follows:0 KJ m-2 (0 min., 0.68 KJ m-2 (2 minutes,2.73 KJ m-2 (4 minutes, and 4.10 KJ m-2 (6 minutes. The apples were stored for 120 days at 5 ± 1°C and analyzed after 0, 30, 60, 90, and 120 days of storage. Radiation doses had no influence on parameters, such as weight loss, firmness and Hue angle, and physicochemical aspects, such as pH, soluble solids, titratable acidity and the soluble solids/titratable acidity ratio. The 4.10 KJ m-2 dose was effective and increased the phenolic content and antioxidant activity for up to 90 days while maintaining the content of vitamin C during storage.

  3. Use of BEIR V and UNSCEAR 1988 in radiation risk assessment: Lifetime total cancer mortality risk estimates at low doses and low dose rates for low-LET radiation

    International Nuclear Information System (INIS)

    1992-12-01

    In November 1986, the Department of Defense (DoD) asked the Committee on Interagency Radiation Research and Policy Coordination (CIRRPC) to develop a coordinated Federal position on risk assessment for low levels of ionizing radiation. Since Federal risk assessment activities are based primarily on the scientific data and analyses in authoritative review documents prepared by groups like the National Academy of Sciences' Committee on the Biological Effects of Ionizing Radiation (BEIR), the National Council on Radiation Protection and Measurements (NCRP) and the United Nations' Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), DoD proposed that the CIRRPC Science Panel undertake the task of providing coordinated interagency positions on the use of information in the reports of such groups. The practice has been for individual Federal agencies to interpret and decide independently how to use the information provided in such reports. As a result of its deliberations, the Subpanel recommends two nominal risk estimates for lifetime total cancer mortality following whole-body exposure to low levels of low-LET ionizing radiation, one for the general population and one for the working-age population (see Section II). The recommended risk estimates reflect the general agreement of information in BEIR V and UNSCEAR 1988 for total cancer mortality. The Subpanel's risk estimates and associated statements are intended to meet the needs of the Federal agencies for: (a) values that are current; (b) values that are relevant to the low-dose and low dose-rate ionizing radiation exposures principally encountered in carrying out Federal responsibilities; (c) a statement of the change in the estimates of lifetime total cancer mortality relative to estimates in previous authoritative review documents; and (d) a practical statement on the scientific uncertainty associated with applying the lifetime total cancer mortality values at very low doses

  4. Radiation protection of medical staff in the latest draft of the revised Euratom Basic Safety Standards directive

    International Nuclear Information System (INIS)

    Simeonov, Georgi; Mundigl, Stefan; Janssens, Augustin

    2011-01-01

    The European Union has a long and successful history of legislating in the area of radiation protection of the public, workers and individuals submitted to medical exposure, the first Euratom “Basic Safety Standards” (BSS) adopted in 1959 and subsequently updated and supplemented with other Directives. The recent revision of this legislation aims to update it in the light of the latest knowledge and experience and to simplify it by consolidating the current legal acts into one Directive. The draft of the revised Euratom BSS Directive has been approved by the group of scientific experts under Euratom Treaty Article 31 and is currently undergoing the European Commission’s procedures. This draft contains several new or amended provisions relating to protection of medical staff, among them: (i) a streamlining of the annual dose limit provisions, (ii) enhancing the use of dose constraints in optimization of protection, and (iii) ensuring better recording and transfer of occupational dose data including in cases of trans-border movement of workers. The Community action to radiation protection of workers is not restricted to passing relevant legislation but also includes ‘soft action’ as issuing guidance, supporting research and stakeholders’ involvement, etc. In August 2010 the Commission issued a Communication to the Council and the European Parliament dealing with the issues in the medical uses of ionizing radiation, including those relating to radiation protection of medical staff.

  5. Simulation of bulk aerosol direct radiative effects and its climatic feedbacks in South Africa using RegCM4

    Science.gov (United States)

    Tesfaye, M.; Botai, J.; Sivakumar, V.; Mengistu Tsidu, G.; Rautenbach, C. J. deW.; Moja, Shadung J.

    2016-05-01

    In this study, 12 year runs of the Regional Climate Model (RegCM4) have been used to analyze the bulk aerosol radiative effects and its climatic feedbacks in South Africa. Due to the geographical locations where the aerosol potential source regions are situated and the regional dynamics, the South African aerosol spatial-distribution has a unique feature. Across the west and southwest areas, desert dust particles are dominant. However, sulfate and carbonaceous aerosols are primarily distributed over the east and northern regions of the country. Analysis of the Radiative Effects (RE) shows that in South Africa the bulk aerosols play a role in reducing the net radiation absorbed by the surface via enhancing the net radiative heating in the atmosphere. Hence, across all seasons, the bulk aerosol-radiation-climate interaction induced statistically significant positive feedback on the net atmospheric heating rate. Over the western and central parts of South Africa, the overall radiative feedbacks of bulk aerosol predominantly induces statistically significant Cloud Cover (CC) enhancements. Whereas, over the east and southeast coastal areas, it induces minimum reductions in CC. The CC enhancement and RE of aerosols jointly induce radiative cooling at the surface which in turn results in the reduction of Surface Temperature (ST: up to -1 K) and Surface Sensible Heat Flux (SSHF: up to -24 W/m2). The ST and SSHF decreases cause a weakening of the convectively driven turbulences and surface buoyancy fluxes which lead to the reduction of the boundary layer height, surface pressure enhancement and dynamical changes. Throughout the year, the maximum values of direct and semi-direct effects of bulk aerosol were found in areas of South Africa which are dominated by desert dust particles. This signals the need for a strategic regional plan on how to reduce the dust production and monitoring of the dust dispersion as well as it initiate the need of further research on different

  6. Direct hospital costs of total laparoscopic hysterectomy compared with fast-track open hysterectomy at a tertiary hospital: a retrospective case-controlled study.

    Science.gov (United States)

    Rhou, Yoon J J; Pather, Selvan; Loadsman, John A; Campbell, Neil; Philp, Shannon; Carter, Jonathan

    2015-12-01

    To assess the direct intraoperative and postoperative costs in women undergoing total laparoscopic hysterectomy and fast-track open hysterectomy. A retrospective review of the direct hospital-related costs in a matched cohort of women undergoing total laparoscopic hysterectomy (TLH) and fast-track open hysterectomy (FTOH) at a tertiary hospital. All costs were calculated, including the cost of advanced high-energy laparoscopic devices. The effect of the learning curve on cost in laparoscopic hysterectomy was also assessed, as was the hospital case-weighted cost, which was compared with the actual cost. Fifty women were included in each arm of the study. TLH had a higher intraoperative cost, but a lower postoperative cost than FTOH (AUD$3877 vs AUD$2776 P funding model in our hospital is inaccurate when compared to directly calculated hospital costs. © 2013 The Authors ANZJOG © 2013 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  7. Reducing Length of Stay, Direct Cost, and Readmissions in Total Joint Arthroplasty Patients With an Outcomes Manager-Led Interprofessional Team.

    Science.gov (United States)

    Arana, Melissa; Harper, Licia; Qin, Huanying; Mabrey, Jay

    The purpose of this quality improvement project was to determine whether an outcomes manager-led interprofessional team could reduce length of stay and direct cost without increasing 30-day readmission rates in the total joint arthroplasty patient population. The goal was to promote interprofessional relationships combined with collaborative practice to promote coordinated care with improved outcomes. Results from this project showed that length of stay (total hip arthroplasty [THA] reduced by 0.4 days and total knee arthroplasty [TKA] reduced by 0.6 days) and direct cost (THA reduced by $1,020 per case and TKA reduced by $539 per case) were significantly decreased whereas 30-day readmission rates of both populations were not significantly increased.

  8. Effect of ionizing radiation and aging time on total phenolics in Brazilian sugarcane spirit with green propolis

    International Nuclear Information System (INIS)

    Aguiar, Claudio L. de; Baptista, Antonio S.; Alencar, Severino M. de; Tiveron, Ana P.; Prado, Adna; Bergamaschi, Keityane B.; Veiga, Lucimara F. da; Baptista, Aparecido S.; Horii, Jorge

    2009-01-01

    Propolis is a natural product from vegetable origin that is generally collected from beehives. This product is well-known for its heath benefits attributed to its biological properties. On the other hand, Brazilian sugarcane spirit, cachaca, shows increasing interest and importance in the alcoholic beverage segment in many markets in the world. Therefore, it was evaluated the addition of propolis into cachaca and the effect of ionizing radiation on propolis compounds with biological activity. Samples of cachaca with propolis used in irradiation experiments were prepared from cachaca (40 deg GL) composed with propolis (0,1 %). Eight treatments, with four repetitions each, were carried out in this study. Three doses of ionizing radiation from electron beam and gamma radiation by 60 Co were applied on the cachaca samples, i.e. 0.5, 1.0, and 2.0 kGy, aiming to accelerate the aging of the cachaca samples. The spirits samples were stored for two periods (immediately after the radiation treatment and 30 months after the treatments) and their phenolic compounds contents were analyzed. Phenolic compounds contents were statistically different between both storage times of the cachaca. The samples of cachaca treated with electron beam at 2.0 kGy presented higher reduction in phenolic compounds contents, approximately 6 % in the first analysis and 11 % in the second analysis. In conclusion, the time of storage to promote reduction on the phenolics compounds and the ionizing radiations from electron beams affect more the contents of these compounds than gamma radiation. (author)

  9. Effect of ionizing radiation and aging time on total phenolics in Brazilian sugarcane spirit with green propolis

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, Claudio L. de; Baptista, Antonio S.; Alencar, Severino M. de; Tiveron, Ana P.; Prado, Adna; Bergamaschi, Keityane B.; Veiga, Lucimara F. da; Baptista, Aparecido S.; Horii, Jorge [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP (Brazil). Dept. de Agroindustria, Alimentos e Nutricao], e-mail: claguiar@esalq.usp.br, e-mail: asbaptis@esalq.usp.br, e-mail: alencar@esalq.usp.br, e-mail: anptiver@esalq.usp.br, e-mail: adprado@esalq.usp.br, e-mail: kbergamas@esalq.usp.br, e-mail: lcfernan@esalq.usp.br, e-mail: pmatao@gmail.com, e-mail: jhorii@esalq.usp.br; Arthur, Valter [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)], e-mail: arthur@cena.usp.br

    2009-07-01

    Propolis is a natural product from vegetable origin that is generally collected from beehives. This product is well-known for its heath benefits attributed to its biological properties. On the other hand, Brazilian sugarcane spirit, cachaca, shows increasing interest and importance in the alcoholic beverage segment in many markets in the world. Therefore, it was evaluated the addition of propolis into cachaca and the effect of ionizing radiation on propolis compounds with biological activity. Samples of cachaca with propolis used in irradiation experiments were prepared from cachaca (40 deg GL) composed with propolis (0,1 %). Eight treatments, with four repetitions each, were carried out in this study. Three doses of ionizing radiation from electron beam and gamma radiation by {sup 60}Co were applied on the cachaca samples, i.e. 0.5, 1.0, and 2.0 kGy, aiming to accelerate the aging of the cachaca samples. The spirits samples were stored for two periods (immediately after the radiation treatment and 30 months after the treatments) and their phenolic compounds contents were analyzed. Phenolic compounds contents were statistically different between both storage times of the cachaca. The samples of cachaca treated with electron beam at 2.0 kGy presented higher reduction in phenolic compounds contents, approximately 6 % in the first analysis and 11 % in the second analysis. In conclusion, the time of storage to promote reduction on the phenolics compounds and the ionizing radiations from electron beams affect more the contents of these compounds than gamma radiation. (author)

  10. Direct determination of lycopene content in tomatoes (Lycopersicon esculentum) by attenuated total reflectance infrared spectroscopy and multivariate analysis.

    Science.gov (United States)

    Halim, Yuwana; Schwartz, Steven J; Francis, David; Baldauf, Nathan A; Rodriguez-Saona, Luis E

    2006-01-01

    Lycopene is a potent antioxidant that has been shown to play critical roles in disease prevention. Efficient assays for detection and quantification of lycopene are desirable as alternatives to time- and labor-intensive methods. Attenuated total reflectance infrared (ATR-IR) spectroscopy was used for quantification of lycopene in tomato varieties. Calibration models were developed by partial least-squares regression (PLSR) using quantitative measures of lycopene concentration from liquid chromatography as reference method. IR spectra showed a distinct marker band at 957 cm(-1) for trans Carbon-Hydrogen (CH) deformation vibration of lycopene. PLSR models predicted the lycopene content accurately and reproducibly with a correlation coefficient (sigma) of 0.96 and standard error of cross-validation ATR-IR spectroscopy allowed for rapid, simple, and accurate determination of lycopene in tomatoes with minimal sample preparation. Results suggest that the ATR-IR method is applicable for high-throughput quantitative analysis and screening for lycopene in tomatoes.

  11. C-reactive protein and serum amyloid A as early-phase and prognostic indicators of acute radiation exposure in nonhuman primate total-body irradiation model

    Energy Technology Data Exchange (ETDEWEB)

    Ossetrova, N.I., E-mail: ossetrova@afrri.usuhs.mil [Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bldg. 42, Bethesda, MD 20889-5603 (United States); Sandgren, D.J.; Blakely, W.F. [Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bldg. 42, Bethesda, MD 20889-5603 (United States)

    2011-09-15

    Terrorist radiological attacks or nuclear accidents could expose large numbers of people to ionizing radiation. In mass-casualty radiological incidents early medical-management requires triage tools for first-responders to quantitatively identify individuals exposed to life-threatening radiation doses and for early initiation (i.e., within one day after radiation exposure) of cytokine therapy for treatment of bone marrow acute radiation syndrome. Herein, we present results from 30 rhesus macaques total-body irradiated (TBI) to a broad dose range of 1-8.5 Gy with {sup 60}Co {gamma}-rays (0.55 Gy min{sup -1}) and demonstrate dose- and time-dependent changes in blood of C-reactive protein (CRP), serum amyloid A (SAA), and interleukin 6 (IL-6) measured by enzyme linked immunosorbent assay (ELISA). CRP and SAA dose-response results are consistent with {approx}1 Gy and {approx}0.2 Gy thresholds for photon-exposure at 24 h after TBI, respectively. Highly significant elevations of CRP and SAA (p = 0.00017 and p = 0.0024, respectively) were found in animal plasma at 6 h after all TBI doses suggesting their potential use as early-phase biodosimeters. Results also show that the dynamics and content of CRP and SAA levels reflect the course and severity of the acute radiation sickness (ARS) and may function as prognostic indicators of ARS outcome. These results demonstrate proof-of-concept that these radiation-responsive proteins show promise as a complementary approach to conventional biodosimetry for early assessment of radiation exposures and may also contribute as diagnostic indices in the medical management of radiation accidents.

  12. Diurnal and seasonal characteristics of the optical properties and direct radiative forcing of different aerosol components in Seoul megacity.

    Science.gov (United States)

    Song, Sang-Keun; Shon, Zang-Ho; Park, Yeon-Hee

    2017-12-01

    The temporal variations (diurnal and seasonal) of the optical properties and direct aerosol radiative forcing (DARF) of different aerosol components (water-soluble, insoluble, black carbon (BC), and sea-salt) were analyzed using the hourly resolution data (PM 2.5 ) measured at an urban site in Seoul, Korea during 2010, based on a modeling approach. In general, the water-soluble component was predominant over all other components (with a higher concentration) in terms of its impact on the optical properties (except for absorbing BC) and DARF. The annual mean aerosol optical depth (AOD, τ) at 500nm for the water-soluble component was 0.38±0.07 (0.06±0.01 for BC). The forcing at the surface (DARF SFC ) and top of the atmosphere (DARF TOA ), and in the atmosphere (DARF ATM ) for most aerosol components (except for BC) during the daytime were highest in spring and lowest in late fall or early winter. The maximum DARF SFC occurred in the morning during most seasons (except for the water-soluble components showing peaks in the afternoon or noon in summer, fall, or winter), while the maximum DARF TOA occurred in the morning during spring and/or winter and in the afternoon during summer and/or fall. The estimated DARF SFC and DARF ATM of the water-soluble component were in the range of -49 to -84Wm -2 and +10 to +22Wm -2 , respectively. The DARF SFC and DARF ATM of BC were -26 to -39Wm -2 and +32 to +51Wm -2 , respectively, showing highest in summer and lowest in spring, with morning peaks regardless of the season. This positive DARF ATM of BC in this study area accounted for approximately 64% of the total atmospheric aerosol forcing due to strong radiative absorption, thus increasing atmospheric heating by 2.9±1.2Kday -1 (heating rate efficiency of 39K day -1 τ -1 ) and then causing further atmospheric warming. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Direct Radiative Impacts of Central American Biomass Burning Smoke Aerosols: Analysis from a Coupled Aerosol-Radiation-Meteorology Model RAMS-AROMA

    Science.gov (United States)

    Wang, J.; Christopher, S. A.; Nair, U. S.; Reid, J. S.; Prins, E. M.

    2005-12-01

    Considerable efforts including various field experiments have been carried out in the last decade for studying the regional climatic impact of smoke aerosols produced by biomass burning activities in Africa and South America. In contrast, only few investigations have been conducted for Central American Biomass Burning (CABB) region. Using a coupled aerosol-radiation-meteorology model called RAMS-AROMA together with various ground-based observations, we present a comprehensive analysis of the smoke direct radiative impacts on the surface energy budget, boundary layer evolution, and e precipitation process during the CABB events in Spring 2003. Quantitative estimates are also made regarding the transboundary carbon mass to the U.S. in the form of smoke particles. Buult upon the Regional Atmospheric Modeling System (RAMS) mesoscale model, the RAMS AROMA has several features including Assimilation and Radiation Online Modeling of Aerosols (AROMA) algorithms. The model simulates smoke transport by using hourly smoke emission inventory from the Fire Locating and Modeling of Burning Emissions (FLAMBE) geostationary satellite database. It explicitly considers the smoke effects on the radiative transfer at each model time step and model grid, thereby coupling the dynamical processes and aerosol transport. Comparison with ground-based observation show that the simulation realistically captured the smoke transport timeline and distribution from daily to hourly scales. The effects of smoke radiative extinction on the decrease of 2m air temperature (2mT), diurnal temperature range (DTR), and boundary layer height over the land surface are also quantified. Warming due to smoke absorption of solar radiation can be found in the lower troposphere over the ocean, but not near the underlying land surface. The increase of boundary layer stability produces a positive feedback where more smoke particles are trapped in the lower boundary layer. These changes in temperature, surface

  14. Computer-assisted surgery simulations and directed practice of total knee arthroplasty: educational benefits to the trainee.

    Science.gov (United States)

    Myden, C A; Anglin, C; Kopp, G D; Hutchison, C R

    2012-01-01

    Orthopaedic residents typically learn to perform total knee arthroplasty (TKA) through an apprenticeship-type model, which is a necessarily slow process. Surgical skills courses, using artificial bones, have been shown to improve technical and cognitive skills significantly within a couple of days. The addition of computer-assisted surgery (CAS) simulations challenges the participants to consider the same task in a different context, promoting cognitive flexibility. We designed a hands-on educational intervention for junior residents with a conventional tibiofemoral TKA station, two different tibiofemoral CAS stations, and a CAS and conventional patellar resection station, including both qualitative and quantitative analyses. Qualitatively, structured interviews before and after the course were analyzed for recurring themes. Quantitatively, subjects were evaluated on their technical skills before and after the course, and on a multiple-choice knowledge test and error detection test after the course, in comparison to senior residents who performed only the testing. Four themes emerged: confidence, awareness, deepening knowledge and changed perspectives. The residents' attitudes to CAS changed from negative before the course to neutral or positive afterwards. The junior resident group completed 23% of tasks in the pre-course skills test and 75% of tasks on the post-test (peducational interventions, promoting cognitive flexibility, would benefit trainees, attending surgeons, the healthcare system and patients.

  15. Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS.

    Science.gov (United States)

    Jakóbik-Kolon, Agata; Milewski, Andrzej; Dydo, Piotr; Witczak, Magdalena; Bok-Badura, Joanna

    2018-02-23

    The fast and simple method for total chlorine determination in polyglycerols using low resolution inductively coupled plasma mass spectrometry (ICP-MS) without the need for additional equipment and time-consuming sample decomposition was evaluated. Linear calibration curve for 35 Cl isotope in the concentration range 20-800 µg/L was observed. Limits of detection and quantification equaled to 15 µg/L and 44 µg/L, respectively. This corresponds to possibility of detection 3 µg/g and determination 9 µg/g of chlorine in polyglycerol using studied conditions (0.5% matrix-polyglycerol samples diluted or dissolved with water to an overall concentration of 0.5%). Matrix effects as well as the effect of chlorine origin have been evaluated. The presence of 0.5% (m/m) of matrix species similar to polyglycerol (polyethylene glycol-PEG) did not influence the chlorine determination for PEGs with average molecular weights (MW) up to 2000 Da. Good precision and accuracy of the chlorine content determination was achieved regardless on its origin (inorganic/organic). High analyte recovery level and low relative standard deviation values were observed for real polyglycerol samples spiked with chloride. Additionally, the Combustion Ion Chromatography System was used as a reference method. The results confirmed high accuracy and precision of the tested method.

  16. Investigation of pUC19 DNA damage induced by direct and indirect effect of 7Li ions radiation

    International Nuclear Information System (INIS)

    Sui Li; Zhao Kui; Guo Jiyu; Ni Meinan; Kong Fuquan; Cai Minghui; Yang Mingjian

    2006-01-01

    The effect of direct and indirect action on DNA damage in 7 Li ions radiation is investigated. Using 7 Li ions generated by HI-13 tandem accelerator, three conditions of pUC19 plasmid DNA samples including dry, with or without mannitol are irradiated at different doses in air. These irradiated DNA samples are analyzed with atomic force microscopy (AFM) in nanometer-scale. The changes of DNA forms as the dose increases are observed. The results show that free radical is the main factor in DNA strand breaks induced by 7 Li ions radiation under condition of aqueous solution. The mannitol can effectively scavenge free radical and reduce the yields of DNA strand breaks. The experimental results of this report can offered valuable basal data for cancer therapy by boron neutron capture therapy (BNCT) or heavy ion radiation method, etc. (author)

  17. Sensitivity of mesoscale modeling of smoke direct radiative effect to the emission inventory: a case study in northern sub-Saharan African region

    International Nuclear Information System (INIS)

    Zhang, Feng; Wang, Jun; Yang, Zhifeng; Ge, Cui; Ichoku, Charles; Hyer, Edward J; Da Silva, Arlindo; Su, Shenjian; Zhang, Xiaoyang; Kondragunta, Shobha; Kaiser, Johannes W; Wiedinmyer, Christine

    2014-01-01

    An ensemble approach is used to examine the sensitivity of smoke loading and smoke direct radiative effect in the atmosphere to uncertainties in smoke emission estimates. Seven different fire emission inventories are applied independently to WRF-Chem model (v3.5) with the same model configuration (excluding dust and other emission sources) over the northern sub-Saharan African (NSSA) biomass-burning region. Results for November and February 2010 are analyzed, respectively representing the start and end of the biomass burning season in the study region. For February 2010, estimates of total smoke emission vary by a factor of 12, but only differences by factors of 7 or less are found in the simulated regional (15°W–42°E, 13°S–17°N) and monthly averages of column PM 2.5 loading, surface PM 2.5 concentration, aerosol optical depth (AOD), smoke radiative forcing at the top-of-atmosphere and at the surface, and air temperature at 2 m and at 700 hPa. The smaller differences in these simulated variables may reflect the atmospheric diffusion and deposition effects to dampen the large difference in smoke emissions that are highly concentrated in areas much smaller than the regional domain of the study. Indeed, at the local scale, large differences (up to a factor of 33) persist in simulated smoke-related variables and radiative effects including semi-direct effect. Similar results are also found for November 2010, despite differences in meteorology and fire activity. Hence, biomass burning emission uncertainties have a large influence on the reliability of model simulations of atmospheric aerosol loading, transport, and radiative impacts, and this influence is largest at local and hourly-to-daily scales. Accurate quantification of smoke effects on regional climate and air quality requires further reduction of emission uncertainties, particularly for regions of high fire concentrations such as NSSA. (paper)

  18. Are lesions induced by ionizing radiation direct blocks to DNA chain elongation

    International Nuclear Information System (INIS)

    Painter, R.B.

    1983-01-01

    Ionizing radiation blocks DNA chain elongation in normal diploid fibroblasts but not in fibroblasts from patients with ataxia-telangiectasia, even though there are no differences in the damage induced between the two cell types. This difference suggests that radiation-induced lesions in DNA are not themselves blocks to chain elongation in ataxia cells and raises the possibility that in normal cells a mediator exists between DNA damage and chain termination

  19. Directed evolution and in silico analysis of reaction centre proteins reveal molecular signatures of photosynthesis adaptation to radiation pressure.

    Directory of Open Access Journals (Sweden)

    Giuseppina Rea

    2011-01-01

    Full Text Available Evolutionary mechanisms adopted by the photosynthetic apparatus to modifications in the Earth's atmosphere on a geological time-scale remain a focus of intense research. The photosynthetic machinery has had to cope with continuously changing environmental conditions and particularly with the complex ionizing radiation emitted by solar flares. The photosynthetic D1 protein, being the site of electron tunneling-mediated charge separation and solar energy transduction, is a hot spot for the generation of radiation-induced radical injuries. We explored the possibility to produce D1 variants tolerant to ionizing radiation in Chlamydomonas reinhardtii and clarified the effect of radiation-induced oxidative damage on the photosynthetic proteins evolution. In vitro directed evolution strategies targeted at the D1 protein were adopted to create libraries of chlamydomonas random mutants, subsequently selected by exposures to radical-generating proton or neutron sources. The common trend observed in the D1 aminoacidic substitutions was the replacement of less polar by more polar amino acids. The applied selection pressure forced replacement of residues more sensitive to oxidative damage with less sensitive ones, suggesting that ionizing radiation may have been one of the driving forces in the evolution of the eukaryotic photosynthetic apparatus. A set of the identified aminoacidic substitutions, close to the secondary plastoquinone binding niche and oxygen evolving complex, were introduced by site-directed mutagenesis in un-transformed strains, and their sensitivity to free radicals attack analyzed. Mutants displayed reduced electron transport efficiency in physiological conditions, and increased photosynthetic performance stability and oxygen evolution capacity in stressful high-light conditions. Finally, comparative in silico analyses of D1 aminoacidic sequences of organisms differently located in the evolution chain, revealed a higher ratio of residues

  20. Satellite orbits perturbed by direct solar radiation pressure: general expansion of the disturbing function

    International Nuclear Information System (INIS)

    Hughes, S.

    1977-01-01

    An expression is derived for the solar radiation pressure disturbing function on an Earth satellite orbit which takes into account the variation of the solar radiation flux with distance from the Sun's centre and the absorption of radiation by the satellite. This expression is then expanded in terms of the Keplerian elements of the satellite and solar orbits using Kaula's method (Astr. J.; 67:300 (1962)). The Kaula inclination functions are replaced by an equivalent set of modified Allan (Proc. R. Soc. A.; 288:60 (1965)) inclination functions. The resulting expression reduces to the form commonly used in solar radiation pressure perturbation studies (e.g. Aksnes, Cel. Mech.; 13:89 (1976)), when certain terms are neglected. If, as happens quite often in practice, a satellite's orbit is in near-resonance with certain of these neglected terms, these near-resonant terms can cause changes in the satellite's orbital elements comparable to those produced by the largest term in Aksnes's expression. A new expression for the solar radiation pressure disturbing function expansion is suggested for use in future studies of satellite orbits perturbed by solar radiation pressure. (author)

  1. The use of gamma-H2AX as a biodosimeter for total-body radiation exposure in non-human primates.

    Directory of Open Access Journals (Sweden)

    Christophe E Redon

    2010-11-01

    Full Text Available There is a crucial shortage of methods capable of determining the extent of accidental exposures of human beings to ionizing radiation. However, knowledge of individual exposures is essential for early triage during radiological incidents to provide optimum possible life-sparing medical procedures to each person.We evaluated immunocytofluorescence-based quantitation of γ-H2AX foci as a biodosimeter of total-body radiation exposure ((60Co γ-rays in a rhesus macaque (Macaca mulatta model. Peripheral blood lymphocytes and plucked hairs were collected from 4 cohorts of macaques receiving total body irradiation doses ranging from 1 Gy to 8.5 Gy. Each cohort consisted of 6 experimental and 2 control animals. Numbers of residual γ-H2AX foci were proportional to initial irradiation doses and statistically significant responses were obtained until 1 day after 1 Gy, 4 days after 3.5 and 6.5 Gy, and 14 days after 8.5 Gy in lymphocytes and until 1 day after 1 Gy, at least 2 days after 3.5 and 6.5 Gy, and 9 days after 8.5 Gy in plucked hairs.These findings indicate that quantitation of γ-H2AX foci may make a robust biodosimeter for analyzing total-body exposure to ionizing radiation in humans. This tool would help clinicians prescribe appropriate types of medical intervention for optimal individual outcome. These results also demonstrate that the use of a high throughput γ-H2AX biodosimeter would be useful for days post-exposure in applications like large-scale radiological events or radiation therapy. In addition, this study validates a possibility to use plucked hair in future clinical trials investigating genotoxic effects of drugs and radiation treatments.

  2. Total hip arthroplasty by the direct anterior approach using a neck-preserving stem: Safety, efficacy and learning curve

    Directory of Open Access Journals (Sweden)

    Aditya Khemka

    2018-01-01

    Full Text Available Background: The concept of femoral neck preservation in total hip replacement (THR was introduced in 1993. It is postulated that retaining cortical bone of the femoral neck offers triplanar stability, uniform stress distribution, and accommodates physiological anteversion. However, data on safety, efficacy and learning curve are lacking. Materials and Methods: We prospectively assessed all patients who were operated for a THR with a short neck preserving stem (MiniHip between 2012 and 2014. The safety and learning curve were assessed by recording operative time; stem size; and adverse events including periprosthetic fracture; paresthesia; and limb length discrepancy (LLD. The cohort was divided into equal groups to assess the learning curve effect, and the cumulative sums (CUSUM test was performed to monitor intraoperative neck fractures. For assessment of efficacy, Oxford Hip Score (OHS and Short Form-36 (SF-36 scores were compared preoperatively and postoperatively. Results: 138 patients with median age 62 years (range 35–82 years were included with a median followup of 42 months (range 30–56 months. The minimum followup was 2.5 years. The OHS, SF-36 (physical and mental component scores improved by a mean score of 26, 28, and 27 points, respectively. All patients had LLD of <10 mm (1.9 mm ± 1.3. Adverse events included intraoperative neck fracture (n = 6, subsidence (n = 1, periprosthetic fracture (n = 1, paresthesia (n = 12, and trochanteric bursitis (n = 2. After early modification of the technique to use a smaller finishing broach, the CUSUM test demonstrated acceptable intraoperative neck fracture risk. The second surgery group had a reduced risk of intraoperative neck fracture (5/69 vs. 1/69 P = 0.2, reduced operative time (66 vs. 61 min, P = 0.06, and increased stem size (5 vs. 6, P = 0.09 although these differences were not statistically significant. Conclusions: The MiniHip stem is safe alternative to standard THR with good

  3. Impact of varying lidar measurement and data processing techniques in evaluating cirrus cloud and aerosol direct radiative effects

    Science.gov (United States)

    Lolli, Simone; Madonna, Fabio; Rosoldi, Marco; Campbell, James R.; Welton, Ellsworth J.; Lewis, Jasper R.; Gu, Yu; Pappalardo, Gelsomina

    2018-03-01

    In the past 2 decades, ground-based lidar networks have drastically increased in scope and relevance, thanks primarily to the advent of lidar observations from space and their need for validation. Lidar observations of aerosol and cloud geometrical, optical and microphysical atmospheric properties are subsequently used to evaluate their direct radiative effects on climate. However, the retrievals are strongly dependent on the lidar instrument measurement technique and subsequent data processing methodologies. In this paper, we evaluate the discrepancies between the use of Raman and elastic lidar measurement techniques and corresponding data processing methods for two aerosol layers in the free troposphere and for two cirrus clouds with different optical depths. Results show that the different lidar techniques are responsible for discrepancies in the model-derived direct radiative effects for biomass burning (0.05 W m-2 at surface and 0.007 W m-2 at top of the atmosphere) and dust aerosol layers (0.7 W m-2 at surface and 0.85 W m-2 at top of the atmosphere). Data processing is further responsible for discrepancies in both thin (0.55 W m-2 at surface and 2.7 W m-2 at top of the atmosphere) and opaque (7.7 W m-2 at surface and 11.8 W m-2 at top of the atmosphere) cirrus clouds. Direct radiative effect discrepancies can be attributed to the larger variability of the lidar ratio for aerosols (20-150 sr) than for clouds (20-35 sr). For this reason, the influence of the applied lidar technique plays a more fundamental role in aerosol monitoring because the lidar ratio must be retrieved with relatively high accuracy. In contrast, for cirrus clouds, with the lidar ratio being much less variable, the data processing is critical because smoothing it modifies the aerosol and cloud vertically resolved extinction profile that is used as input to compute direct radiative effect calculations.

  4. Prospective study of total cholesterol amount in the blood of the persons exposed to ionizing radiation due to Chernobyl accident

    International Nuclear Information System (INIS)

    Chobot'ko, G.M.

    1998-01-01

    The blood of the men aged 20-59 residing in Kyiv after the accident and that of the participants of the accident clean-up aged 25-55 has been studying for 10 years. The nature of the observed changes in blood cholesterol amount is atherogenic, which should be taken into account when taking preventive and therapeutic measures in the persons exposed to different dosed of ionizing radiation

  5. Effect of the ionizing radiation and aging time on total flavonoids contents in Brazilian sugarcane spirit composed with green propolis

    International Nuclear Information System (INIS)

    Baptista, Antonio S.; Alencar, Severino M. de; Tiveron, Ana P.; Prado, Adna; Bergamaschi, Keityane B.; Veiga, Lucimara F. da; Aguiar, Claudio L. de; Baptista, Aparecido S.; Horii, Jorge

    2009-01-01

    Propolis is a natural product from vegetable origin, but, this substance, in general, is collected in the beehives. This product is largely known because its heath benefit attributed to its biological properties. On the other hand, Brazilian sugarcane spirit, 'cachaca', is an interesting alcoholic beverage with an increasing importance in the segment in many markets in the world. Therefore, was evaluating the addition of the propolis into cachaca and the effect of ionizing radiation on propolis compounds with biological properties. Samples of cachaca with propolis used in irradiation experiments were prepared from cachaca (40 deg GL) composed with propolis (0.1%). Eight treatments, with four repetitions each, were considered in this study. Three doses of ionizing energy from electron beam and gamma radiation from 60 Co were applied on the cachaca samples, i.e. 0.5, 1.0, and 2.0 kGy, with the goal to accelerate the aging time of the cachaca. The sugarcane spirits samples were storage during two periods (immediately after the radiation treatment and 30 months after the treatments) and their flavonoids contents were analyzed. Flavonoids contents in sugarcane spirit were statistically different between both storage time. The samples of cachaca treated with electron beam at 2.0 kGy presented the highest reduction in flavonoids contents, approximately 30.0 % in relation to the first analysis time. In conclusion, the time of storage to promote reduction on the flavonoids contents and the ionizing radiation also promoted reduction on the contents of these compounds, mainly in the first period of storage. (author)

  6. Effect of the ionizing radiation and aging time on total flavonoids contents in Brazilian sugarcane spirit composed with green propolis

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Antonio S.; Alencar, Severino M. de; Tiveron, Ana P.; Prado, Adna; Bergamaschi, Keityane B.; Veiga, Lucimara F. da; Aguiar, Claudio L. de; Baptista, Aparecido S.; Horii, Jorge [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP (Brazil). Dept. de Agroindustria, Alimentos e Nutricao], e-mail: asbaptis@esalq.usp.br, e-mail: alencar@esalq.usp.br, e-mail: anptiver@esalq.usp.br, e-mail: adprado@esalq.usp.br, e-mail: kbergamas@esalq.usp.br, e-mail: lcfernan@esalq.usp.br, e-mail: claguiar@esalq.usp.br, e-mail: pmatao@gmail.com, e-mail: jhorii@esalq.usp.br; Arthur, Valter [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)], e-mail: arthur@cena.usp.br

    2009-07-01

    Propolis is a natural product from vegetable origin, but, this substance, in general, is collected in the beehives. This product is largely known because its heath benefit attributed to its biological properties. On the other hand, Brazilian sugarcane spirit, 'cachaca', is an interesting alcoholic beverage with an increasing importance in the segment in many markets in the world. Therefore, was evaluating the addition of the propolis into cachaca and the effect of ionizing radiation on propolis compounds with biological properties. Samples of cachaca with propolis used in irradiation experiments were prepared from cachaca (40 deg GL) composed with propolis (0.1%). Eight treatments, with four repetitions each, were considered in this study. Three doses of ionizing energy from electron beam and gamma radiation from {sup 60}Co were applied on the cachaca samples, i.e. 0.5, 1.0, and 2.0 kGy, with the goal to accelerate the aging time of the cachaca. The sugarcane spirits samples were storage during two periods (immediately after the radiation treatment and 30 months after the treatments) and their flavonoids contents were analyzed. Flavonoids contents in sugarcane spirit were statistically different between both storage time. The samples of cachaca treated with electron beam at 2.0 kGy presented the highest reduction in flavonoids contents, approximately 30.0 % in relation to the first analysis time. In conclusion, the time of storage to promote reduction on the flavonoids contents and the ionizing radiation also promoted reduction on the contents of these compounds, mainly in the first period of storage. (author)

  7. Zonal Aerosol Direct and Indirect Radiative Forcing using Combined CALIOP, CERES, CloudSat, and CERES Data

    Science.gov (United States)

    Miller, W. F.; Kato, S.; Rose, F. G.; Sun-Mack, S.

    2009-12-01

    Under the NASA Energy and Water Cycle System (NEWS) program, cloud and aerosol properties derived from CALIPSO, CloudSat, and MODIS data then matched to the CERES footprint are used for irradiance profile computations. Irradiance profiles are included in the publicly available product, CCCM. In addition to the MODIS and CALIPSO generated aerosol, aerosol optical thickness is calculated over ocean by processing MODIS radiance through the Stowe-Ignatov algorithm. The CERES cloud mask and properties algorithm are use with MODIS radiance to provide additional cloud information to accompany the actively sensed data. The passively sensed data is the only input to the standard CERES radiative flux products. The combined information is used as input to the NASA Langley Fu-Liou radiative transfer model to determine vertical profiles and Top of Atmosphere shortwave and longwave flux for pristine, all-sky, and aerosol conditions for the special data product. In this study, the three sources of aerosol optical thickness will be compared directly and their influence on the calculated and measured TOA fluxes. Earlier studies indicate that the largest uncertainty in estimating direct aerosol forcing using aerosol optical thickness derived from passive sensors is caused by cloud contamination. With collocated CALIPSO data, we are able to estimate frequency of occurrence of cloud contamination, effect on the aerosol optical thickness and direct radiative effect estimates.

  8. Daytime relapse of the mean radiant temperature based on the six-directional method under unobstructed solar radiation.

    Science.gov (United States)

    Kántor, Noémi; Lin, Tzu-Ping; Matzarakis, Andreas

    2014-09-01

    This study contributes to the knowledge about the capabilities of the popular "six-directional method" describing the radiation fields outdoors. In Taiwan, measurements were carried out with three orthogonally placed net radiometers to determine the mean radiant temperature (T(mrt)). The short- and long-wave radiation flux densities from the six perpendicular directions were recorded in the daylight hours of 12 days. During unobstructed direct irradiation, a specific daytime relapse was found in the temporal course of the T(mrt) values referring to the reference shapes of a standing man and also of a sphere. This relapse can be related to the short-wave fluxes reaching the body from the lateral directions. Through deeper analysis, an instrumental shortcoming of the six-directional technique was discovered. The pyranometer pairs of the same net radiometer have a 10-15-min long "blind spot" when the sun beams are nearly perpendicular to them. The blind-spot period is supposed to be shorter with steeper solar azimuth curve on the daylight period. This means that the locations with lower geographical latitude, and the summertime measurements, are affected less by this instrumental problem. A methodological shortcoming of the six-directional technique was also demonstrated. Namely, the sum of the short-wave flux densities from the lateral directions is sensitive to the orientation of the radiometers, and therefore by deviating from the original directions, the T(mrt) decrease on clear sunny days will occur in different times and will be different in extent.

  9. Intensity-modulated radiation therapy using static ports of tomotherapy (TomoDirect): comparison with the TomoHelical mode

    International Nuclear Information System (INIS)

    Murai, Taro; Shibamoto, Yuta; Manabe, Yoshihiko; Murata, Rumi; Sugie, Chikao; Hayashi, Akihiro; Ito, Hiroya; Miyoshi, Yoshihito

    2013-01-01

    With the new mode of Tomotherapy, irradiation can be delivered using static ports of the TomoDirect mode. The purpose of this study was to evaluate the characteristics of TomoDirect plans compared to conventional TomoHelical plans. TomoDirect and TomoHelical plans were compared in 46 patients with a prostate, thoracic wall or lung tumor. The mean target dose was used as the prescription dose. The minimum coverage dose of 95% of the target (D95%), conformity index (CI), uniformity index (UI), dose distribution in organs at risk and treatment time were evaluated. For TomoDirect, 2 to 5 static ports were used depending on the tumor location. For the prostate target volume, TomoDirect plans could not reduce the rectal dose and required a longer treatment time than TomoHelical. For the thoracic wall target volume, the V5Gy of the lung or liver was lower in TomoDirect than in TomoHelical (p = 0.02). For the lung target volume, TomoDirect yielded higher CI (p = 0.009) but smaller V5Gy of the lung (p = 0.005) than TomoHelical. Treatment time did not differ significantly between the thoracic wall and lung plans. Prostate cancers should be treated with the TomoHelical mode. Considering the risk of low-dose radiation to the lung, the TomoDirect mode could be an option for thoracic wall and lung tumors

  10. Assessing the relationship between total factor productivity and foreign direct investment in an economy with a skills shortage: the case of South Africa

    OpenAIRE

    Bonga-Bonga, Lumengo; Phume, Maphelane

    2017-01-01

    This paper assesses the relationship between total factor productivity (TFP) and foreign direct investment (FDI) in a country with skills shortage. South Africa is used as a case study. Literature is inconclusive on how FDI should affect TFP. This paper shows that it is important to account for the interactivity between FDI and human capital when assessing the effects of FDI on TFP. Moreover, the empirical results show that, contrary to countries with abundance of skills, in countries with sk...

  11. Using a progress computer for the direct acquisition and processing of radiation protection data

    International Nuclear Information System (INIS)

    Barz, H.G.; Borchardt, K.D.; Hacke, J.; Kirschfeld, K.E.; Kluppak, B.

    1976-01-01

    A process computer will be used in the Hahn-Meitner-Institute to rationalize radiation protection measures. Appr. 150 transmitters are to be connected with this computer. Especially the radiation measuring devices of a nuclear reactor, of hot cells, and of a heavy ion accelerator, as well as the emission- and environment monitoring systems will be connected. The advantages of this method are described: central data acquisition, central alarm and stoppage information, data processing of certain measurement values, possibility of quick disturbance analysis. Furthermore the authors report about the preparations already finished, particularly about data transmission of digital and analog values to the computer. (orig./HP) [de

  12. System for monitoring the position, intensity, uniformity, and directivity of a beam of ionizing radiation

    International Nuclear Information System (INIS)

    Boux, R.

    1976-01-01

    A monitoring device transparent to ionizing radiation, designed to measure the orientation, intensity and uniformity of an incident beam, comprises a cylindrical housing forming at least one ionization chamber with one or more ion-collecting electrodes transverse to the housing axis, each electrode being subdivided into a plurality of mutually insulated conductive elements connected to respective amplifiers. The elements of at least one electrode include one or more outer elements surrounding or bracketing one or more inner elements to measure the radiation in a central zone and a peripheral zone. The outputs of the respective amplifiers are additively and subtractively combined in an evaluation circuit

  13. Aerosol Direct Radiative Forcing and Forcing Efficiencies at Surface from the shortwave Irradiance Measurements in Abu Dhabi, UAE

    Science.gov (United States)

    Beegum S, N.; Ben Romdhane, H.; Ghedira, H.

    2013-12-01

    Atmospheric aerosols are known to affect the radiation balance of the Earth-Atmospheric system directly by scattering and absorbing the solar and terrestrial radiation, and indirectly by affecting the lifetime and albedo of the clouds. Continuous and simultaneous measurements of short wave global irradiance in combination with synchronous spectral aerosol optical depth (AOD) measurements (from 340 nm to 1640 nm in 8 channels), for a period of 1 year from June 2012 to May 2013, were used for the determination of the surface direct aerosol radiative forcing and forcing efficiencies under cloud free conditions in Abu Dhabi (24.42°N, 54.61o E, 7m MSL), a coastal location in United Arab Emirates (UAE) in the Arabian Peninsula. The Rotating Shadow band Pyranometer (RSP, LI-COR) was used for the irradiance measurements (in the spectral region 400-1100 nm), whereas the AOD measurements were carried out using CIMEL Sunphotometer (CE 318-2, under AERONET program). The differential method, which is neither sensitive to calibration uncertainties nor model assumptions, has been employed for estimating forcing efficiencies from the changes in the measured fluxes. The forcing efficiency, which quantifies the net change in irradiance per unit change in AOD, is an appropriate parameter for the characterization of the aerosol radiative effects even if the microphysical and optical properties of the aerosols are not completely understood. The corresponding forcing values were estimated from the forcing efficiencies. The estimated radiative forcing and forcing efficiencies exhibited strong monthly variations. The forcing efficiencies (absolute magnitudes) were highest during March, and showed continuous decrease thereafter to reach the lowest value during September. In contrast, the forcing followed a slightly different pattern of variability, with the highest solar dimming during April ( -60 W m-2) and the minimum during February ( -20 W m-2). The results indicate that the aerosol

  14. Radiation protection regulations in Slovakia and application of BSS and EC council directives provisions

    International Nuclear Information System (INIS)

    Viktory, D.

    2003-01-01

    Slovakia, a part of the former Czechoslovak Federation, has been on the map of Europe as an independent country for only 10 years. It is a relatively small country with 5,5 million of inhabitants. The use of radiation sources in medicine, industry and research is extensive, but it corresponds with the size of country and the number of inhabitants. Nowadays here are nearly 600 licensee holders in medicine and in industry and 5 000 radiation sources in national registry. The nuclear industry is relatively developed in Slovakia. In the former Czechoslovakia, the responsibilities for nuclear safety and radiation protection were divided between two authorities. The federal authority for nuclear safety and regional authorities - regional hygienist for the radiation protection were responsible. Regional health protection authorities were managed by two separate Ministries of the Health of Czech and Slovak federal Republics. After the splitting of Czechoslovakia the development differs slightly in both countries. In the Czech Republic both authorities have merged, in Slovakia the people in power were not able to carry out such a radical change, so here the model of two independent authorities have remained. This system has been working since 1950's. (author)

  15. CARS Measurement of Vibrational/Rotational Temperatures with Total Radiation Visualization behind Strong Shock Waves of 5-7 km/s

    Science.gov (United States)

    Sakurai, K.; Bindu, V. Hima; Niinomi, S.; Ota, M.; Maeno, K.

    2011-05-01

    In the development of aerospace technology the design of space vehicles is important in phase of reentry flight. The space vehicles reenter into the atmosphere with range of 6-8 km/s. The non-equilibrium flow with radiative heating from strongly shocked air ahead of the vehicles plays an important role on the heat flux to the wall surface structure as well as convective heating. The experimental data for re-entry analyses, however, have remained in classical level. Recent development of optical instruments enables us to have novel approach of diagnostics to the re-entry problems. We employ the CARS (Coherent Anti-Stokes Raman Spectroscopy) method for measurement of real gas temperatures of N2 with radiation of the strong shock wave. The CARS signal can be acquired even in the strong radiation area behind the strong shock waves. In addition, we try to use the CCD camera to obtain 2D images of total radiation simultaneously. The strong shock wave in front of the reentering space vehicles is experimentally realigned by free-piston, double-diaphragm shock tube with low density test gas.

  16. The direct radiative effect of wildfire smoke on a severe thunderstorm event in the Baltic Sea region

    Science.gov (United States)

    Toll, V.; Männik, A.

    2015-03-01

    On August 8, 2010, a severe derecho type thunderstorm in the Baltic Sea region coincided with smoke from wildfires in Russia. Remarkable smoke aerosol concentrations, with a maximum aerosol optical depth of more than 2 at 550 nm, were observed near the thunderstorm. The impact of the wildfire smoke on the thunderstorm through direct radiative effects was investigated using the Hirlam Aladin Research for Mesoscale Operational Numerical Weather Prediction in Euromed (HARMONIE) model. HARMONIE was successfully able to resolve the dynamics of the thunderstorm, and simulations that considered the influence of the smoke-related aerosols were compared to simulation without aerosols. As simulated by the HARMONIE model, the smoke reduced the shortwave radiation flux at the surface by as much as 300 W/m2 and decreased the near-surface temperature by as much as 3 °C in the vicinity of the thunderstorm and respectively 100 W/m2 and 1 °C in the thunderstorm region. Atmospheric instability decreased through the direct radiative effect of aerosols, and several dynamic features of the simulated thunderstorm appeared slightly weaker.

  17. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    Energy Technology Data Exchange (ETDEWEB)

    Fittschen, U.E.A. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: ursula.fittschen@chemie.uni-hamburg.de; Meirer, F. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: fmeirer@ati.ac.at; Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: streli@ati.ac.at; Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: wobi@ati.ac.at; Thiele, J. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: Julian.Thiele@gmx.de; Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22603 Hamburg (Germany)], E-mail: falkenbe@mail.desy.de; Pepponi, G. [ITC-irst, Via Sommarive 18, 38050 Povo (Trento) (Italy)], E-mail: pepponi@itc.it

    2008-12-15

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 {mu}m, 8.0-2.0 {mu}m, 2.0-0.13 {mu}m 0.13-0.015 {mu}m (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 {mu}m, 1-2 {mu}m, 2-4 {mu}m, 4-8 {mu}m, 8-16 {mu}m. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in

  18. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    International Nuclear Information System (INIS)

    Fittschen, U.E.A.; Meirer, F.; Streli, C.; Wobrauschek, P.; Thiele, J.; Falkenberg, G.; Pepponi, G.

    2008-01-01

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 μm, 8.0-2.0 μm, 2.0-0.13 μm 0.13-0.015 μm (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 μm, 1-2 μm, 2-4 μm, 4-8 μm, 8-16 μm. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in all particle size fractions

  19. Analysis of the ozone profile specifications in the WRF-ARW model and their impact on the simulation of direct solar radiation

    Directory of Open Access Journals (Sweden)

    A. Montornès

    2015-03-01

    Full Text Available Although ozone is an atmospheric gas with high spatial and temporal variability, mesoscale numerical weather prediction (NWP models simplify the specification of ozone concentrations used in their shortwave schemes by using a few ozone profiles. In this paper, a two-part study is presented: (i an evaluation of the quality of the ozone profiles provided for use with the shortwave schemes in the Advanced Research version of the Weather Research and Forecasting (WRF-ARW model and (ii an assessment of the impact of deficiencies in those profiles on the performance of model simulations of direct solar radiation. The first part compares simplified data sets used to specify the total ozone column in six schemes (i.e., Goddard, New Goddard, RRTMG, CAM, GFDL and Fu–Liou–Gu with the Multi-Sensor Reanalysis data set during the period 1979–2008 examining the latitudinal, longitudinal and seasonal limitations in the ozone profile specifications of each parameterization. The results indicate that the maximum deviations are over the poles and show prominent longitudinal patterns in the departures due to the lack of representation of the patterns associated with the Brewer–Dobson circulation and the quasi-stationary features forced by the land–sea distribution, respectively. In the second part, the bias in the simulated direct solar radiation due to these deviations from the simplified spatial and temporal representation of the ozone distribution is analyzed for the New Goddard and CAM schemes using the Beer–Lambert–Bouguer law and for the GFDL using empirical equations. For radiative applications those simplifications introduce spatial and temporal biases with near-zero departures over the tropics throughout the year and increasing poleward with a maximum in the high middle latitudes during the winter of each hemisphere.

  20. Monthly and seasonal variations of aerosol optical properties and direct radiative forcing over Zanjan, Iran

    Science.gov (United States)

    Gharibzadeh, Maryam; Alam, Khan; Abedini, Yousefali; Bidokhti, Abbasali Aliakbari; Masoumi, Amir

    2017-11-01

    Aerosol optical properties and radiative forcing over Zanjan in northwest of Iran has been analyzed during 2010-2013. The aerosol optical and radiative properties are less studied over Zanjan, and therefore, require a careful and in depth analysis. The optical properties like Aerosol Optical Depth (AOD), Ångström Exponent (AE), ASYmmetry parameter (ASY), Single Scattering Albedo (SSA), and Aerosol Volume Size Distribution (AVSD) have been evaluated using the ground-based AErosol RObotic NETwork (AERONET) data. Higher AOD while relatively lower AE were observed in the spring and summer, which showed the presence of coarse mode particles in these seasons. An obvious increase of coarse mode particles in AVSD distribution, as well as a higher value of SSA represented considerable addition of coarse mode particles like dust into the atmosphere of Zanjan in these two seasons. Increase in AE, while a decrease in AOD was detected in the winter and fall. The presence of fine particles indicates the dominance of particles like urban-industrial aerosols from local sources especially in the winter. The Santa Barbara DISORT Atmospheric Radiative Transfer (SBDART) model was utilized to calculate the Aerosol Radiative Forcing (ARF) at the Top of the Atmosphere (TOA), earth's surface and within the atmosphere. The annual averaged ARF values were -13.47 W m-2 and -36.1 W m-2 at the TOA and earth's surface, respectively, which indicate a significant cooling effect. Likewise, the ARF efficiencies at the TOA and earth's surface were -65.08 W m-2 and -158.43 W m-2, respectively. The annual mean atmospheric ARF and heating rate within the atmosphere were 22.63 W m-2 and 0.27 Kday-1 respectively, represented the warming effect within the atmosphere. Finally, a good agreement was found between AERONET retrieved ARF and SBDART simulated ARF.

  1. A Nonlinear Autoregressive Exogenous (NARX Neural Network Model for the Prediction of the Daily Direct Solar Radiation

    Directory of Open Access Journals (Sweden)

    Zina Boussaada

    2018-03-01

    Full Text Available The solar photovoltaic (PV energy has an important place among the renewable energy sources. Therefore, several researchers have been interested by its modelling and its prediction, in order to improve the management of the electrical systems which include PV arrays. Among the existing techniques, artificial neural networks have proved their performance in the prediction of the solar radiation. However, the existing neural network models don’t satisfy the requirements of certain specific situations such as the one analyzed in this paper. The aim of this research work is to supply, with electricity, a race sailboat using exclusively renewable sources. The developed solution predicts the direct solar radiation on a horizontal surface. For that, a Nonlinear Autoregressive Exogenous (NARX neural network is used. All the specific conditions of the sailboat operation are taken into account. The results show that the best prediction performance is obtained when the training phase of the neural network is performed periodically.

  2. Radiation induced asymmetries in mitotic recombination: evidence for a directional bias in the formation of asymmetric hybrid DNA in yeast

    International Nuclear Information System (INIS)

    Friedman, L.R.; Sobell, H.M.

    We have examined radiation-induced mitotic recombination using two alleles (his1-36, his1-49) in the his1 gene. When the haploid containing his1-36 is irradiated with varying doses of γ rays and then mated with the unirradiated strain containing his1-49, analyses of the selected prototrophs show them to be primarily + +/+ 49. If, on the other hand, the haploid strain containing his1-49 is the irradiated parent, the prototrophic diploids are primarily + +/36 +. In control experiments, where either both strains are irradiated or not irradiated, no such asymmetries are found. These data indicate that the irradiated haploid chromosome tends to be the recipient of genetic information. We interpret these results as indicating a directional bias in the formation of hybrid DNA in radiation-induced mitotic recombination, and discuss these results in terms of current models of genetic recombination

  3. Ten-year results of a randomized clinical trial comparing radical mastectomy and total mastectomy with or without radiation

    International Nuclear Information System (INIS)

    Fisher, B.; Redmond, C.; Fisher, E.R.

    1985-01-01

    In 1971 a randomized trial was begun to compare alternative local and regional treatments of breast cancer, all of which employ breast removal. Life-table estimates were obtained for 1665 women enrolled in the study for a mean of 126 months. There were no significant differences among three groups of patients with clinically negative auxillary nodes, with respect to disease-free survival, distant-disease-free survival, or overall survival (about 57%) at 10 years. The patients were treated by radical mastectomy, total (simple) mastectomy without auxillary dissection but with regional irradiation, or total mastectomy without irradiation plus auxillary dissection only if nodes were subsequently positive. Similarly, no differences, were observed between patients with clinically positive nodes treated by radical mastectomy or by total mastectomy without auxillary dissection but with regional irradiation. Survival at 10 years was about 38% in both groups. Our findings indicate that the location of a breast tumor does not influence the prognosis and that irradiation of internal mammary nodes in patients with inner-quadrant lesions does not improve survival. The data also demonstrate that the results obtained at five years accurately predict the outcome at 10 years. It was concluded that the variations of local and regional treatment used in this study are not important in determining survival of patients with breast cancer. 25 references, 6 figures, 1 table

  4. Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty; Dosisreduktion in der digitalen Radiografie des Kniegelenkes nach endoprothetischem Gelenkersatz

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, J.K.; Kauczor, H.U.; Weber, M.A. [University Hospital Heidelberg (Germany). Clinic for Diagnostic and Interventional Radiology; Tanner, M.; Ewerbeck, V. [University Hospital Heidelberg (Germany). Center of Orthopedics, Trauma and Spinal Cord Injury; Stiller, W. [German Cancer Research Center (DKFZ), Radiology (E010), Heidelberg (Germany); Burkholder, I. [Univ. of Applied Sciences of the Saarland, Dept. of Nursing and Health, Saarbruecken (Germany)

    2015-08-15

    To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. In this prospective randomized study 278 radiographs of the knee in follow-up of total-knee arthroplasty were performed with standard and 37 % reduced radiation dose. The evaluation of the plain-radiographs was conducted using the following criteria: bone-implant interface, implant-surface character, implant-implant discrimination and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score ≥ 3 or more than 2 criteria with ≥ 2 points, the radiograph was score das ''not assessable''. The study was designed as non-inferiority-trial. 100 % of examined radiographs were scored as assessable, hence no statistical inferiority between the examinations with standard and reduced dose could be observed. Singular assessment of the defined criteria was likewise dose-independent. Plain-radiography of the knee following total-knee arthroplasty can be performed with 63 % of standard dose without loss of diagnostic validity.

  5. Non-relativistic Free–Free Emission due to the n -distribution of Electrons—Radiative Cooling and Thermally Averaged and Total Gaunt Factors

    Energy Technology Data Exchange (ETDEWEB)

    De Avillez, Miguel A. [Department of Mathematics, University of Évora, R. Romão Ramalho 59, 7000 Évora (Portugal); Breitschwerdt, Dieter, E-mail: mavillez@galaxy.lca.uevora.pt [Zentrum für Astronomie und Astrophysik, Technische Universität Berlin, Hardenbergstrasse 36, D-10623 Berlin (Germany)

    2017-09-01

    Tracking the thermal evolution of plasmas, characterized by an n -distribution, using numerical simulations, requires the determination of the emission spectra and of the radiative losses due to free–free emission from the corresponding temperature-averaged and total Gaunt factors. Detailed calculations of the latter are presented and associated with n -distributed electrons with the parameter n ranging from 1 (corresponding to the Maxwell–Boltzmann distribution) to 100. The temperature-averaged and total Gaunt factors with decreasing n tend toward those obtained with the Maxwell–Boltzmann distribution. Radiative losses due to free–free emission in a plasma evolving under collisional ionization equilibrium conditions and composed by H, He, C, N, O, Ne, Mg, Si, S, and Fe ions, are presented. These losses decrease with a decrease in the parameter n , reaching a minimum when n  = 1, and thus converge with the loss of thermal plasma. Tables of the thermal-averaged and total Gaunt factors calculated for n -distributions, and a wide range of electron and photon energies, are presented.

  6. Non-relativistic Free–Free Emission due to the n -distribution of Electrons—Radiative Cooling and Thermally Averaged and Total Gaunt Factors

    International Nuclear Information System (INIS)

    De Avillez, Miguel A.; Breitschwerdt, Dieter

    2017-01-01

    Tracking the thermal evolution of plasmas, characterized by an n -distribution, using numerical simulations, requires the determination of the emission spectra and of the radiative losses due to free–free emission from the corresponding temperature-averaged and total Gaunt factors. Detailed calculations of the latter are presented and associated with n -distributed electrons with the parameter n ranging from 1 (corresponding to the Maxwell–Boltzmann distribution) to 100. The temperature-averaged and total Gaunt factors with decreasing n tend toward those obtained with the Maxwell–Boltzmann distribution. Radiative losses due to free–free emission in a plasma evolving under collisional ionization equilibrium conditions and composed by H, He, C, N, O, Ne, Mg, Si, S, and Fe ions, are presented. These losses decrease with a decrease in the parameter n , reaching a minimum when n  = 1, and thus converge with the loss of thermal plasma. Tables of the thermal-averaged and total Gaunt factors calculated for n -distributions, and a wide range of electron and photon energies, are presented.

  7. Lyman-alpha detector designed for rocket measurements of the direct solar radiation at 121.5 nm

    International Nuclear Information System (INIS)

    Guineva, V.; Tashev, V.; Witt, G.; Gumbel, J.; Khaplanov, M.

    2007-01-01

    Rocket measurements of the direct Lyman-alpha radiation penetrating in the atmosphere were planned during the HotPay I rocket experiment, June 2006, Project ASLAF (Attenuation of the Solar Lyman-Alpha Flux), Andoya Rocket Range (ARR), Norway. The basic goal of ASLAF project was the study of the processes in the summer mesosphere and thermosphere (up to 110 km), at high latitudes using the Lyman-alpha measurements. The resonance transition 2 P- 2 S of the atomic hydrogen (Lyman-alpha emission) is the strongest and most conspicuous feature in the solar EUV spectrum. Due to the favourable circumstance, that the Lyman-alpha wavelength (121.5 nm) coincides with a minimum of the O 2 absorption spectrum, the direct Lyman-alpha radiation penetrates well in the mesosphere. The Lyman-alpha radiation is the basic agent of the NO molecules ionization, thus generating the ionospheric D-layer, and of the water vapour photolysis, being one of the main H 2 O loss processes. The Lyman-alpha radiation transfer depends on the resonance scattering from the hydrogen atoms in the atmosphere and on the O 2 absorption. Since the Lyman-alpha extinction in the atmosphere is a measure for the column density of the oxygen molecules, the atmospheric temperature profile can be calculated thereof. The detector of solar Lyman-alpha radiation was manufactured in the Stara Zagora Department of the Solar-Terrestrial Influences Laboratory (STIL). Its basic part is an ionization chamber, filled in with NO. A 60 V power supply is applied to the chamber. The produced photoelectric current from the sensor is fed to a 2-channels amplifier, providing an analogue signal. The characteristics of the Lyman-alpha detector were studied. It passed successfully all tests and the results showed that the instrument could be used in rocket experiments to measure the Lyman-alpha flux. From the measurements of the detector, the Lyman-alpha vertical profile can be obtained. The forthcoming scientific data analysis will

  8. Decomposition and decoloration of a direct dye by electron beam radiation

    International Nuclear Information System (INIS)

    Vahdat, Ali; Bahrami, S.H.; Arami, M.; Motahari, A.

    2010-01-01

    The wastewaters released by textile industries to the environment contain hazardous compounds like toxic refractory dye stuff at high concentration. In this study, electron beam irradiation-induced decoloration and decomposition of C.I. Direct Black 22 aqueous solutions were investigated. The influences of absorbed doses and initial dye concentration on the percent of decoloration, COD and pH of the solutions are described. The results show that the direct dye solutions can be effectively degraded by electron beam irradiation.

  9. Direct bound on the total decay width of the top quark in pp collisions at sqrt[s]=1.96 TeV.

    Science.gov (United States)

    Aaltonen, T; Adelman, J; Akimoto, T; Albrow, M G; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Apresyan, A; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Azzurri, P; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Bartsch, V; Bauer, G; Beauchemin, P-H; Bedeschi, F; Bednar, P; Beecher, D; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Beringer, J; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Bridgeman, A; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Calancha, C; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Compostella, G; Convery, M E; Conway, J; Copic, K; Cordelli, M; Cortiana, G; Cox, D J; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; Dagenhart, D; Datta, M; Davies, T; de Barbaro, P; De Cecco, S; Deisher, A; De Lorenzo, G; Dell'orso, M; Deluca, C; Demortier, L; Deng, J; Deninno, M; Derwent, P F; di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Elagin, A; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garberson, F; Garcia, J E; Garfinkel, A F; Genser, K; Gerberich, H; Gerdes, D; Gessler, A; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C M; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Han, B-Y; Han, J Y; Handler, R; Happacher, F; Hara, K; Hare, D; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hauser, J; Hays, C; Heck, M; Heijboer, A; Heinemann, B; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hewamanage, S; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jayatilaka, B; Jeon, E J; Jha, M K; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Kar, D; Karchin, P E; Kato, Y; Kephart, R; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Knuteson, B; Ko, B R; Koay, S A; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhr, T; Kulkarni, N P; Kurata, M; Kusakabe, Y; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecompte, T; Lee, E; Lee, H S; Lee, S W; Leone, S; Lewis, J D; Lin, C S; Linacre, J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Lovas, L; Lu, R-S; Lucchesi, D; Lueck, J; Luci, C; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; Macqueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Marino, C P; Martin, A; Martin, V; Martínez, M; Martínez-Ballarín, R; Maruyama, T; Mastrandrea, P; Masubuchi, T; Mattson, M E; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzione, A; Merkel, P; Mesropian, C; Miao, T; Miladinovic, N; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyake, H; Moggi, N; Moon, C S; Moore, R; Morello, M J; Morlok, J; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Nagano, A; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Norman, M; Norniella, O; Nurse, E; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Osterberg, K; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Pueschel, E; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Reisert, B; Rekovic, V; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Saarikko, H; Safonov, A; Sakumoto, W K; Saltó, O; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, A; Schmidt, E E; Schmidt, M A; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sfyrla, A; Shalhout, S Z; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shiraishi, S; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spreitzer, T; Squillacioti, P; Stanitzki, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Suslov, I; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thompson, G A; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Tourneur, S; Tu, Y; Turini, N; Ukegawa, F; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Vellidis, C; Veszpremi, V; Vidal, M; Vidal, R; Vila, I; Vilar, R; Vine, T; Vogel, M; Volobouev, I; Volpi, G; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner-Kuhr, J; Wagner, W; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Wynne, S M; Xie, S; Yagil, A; Yamamoto, K; Yamaoka, J; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zhang, X; Zheng, Y; Zucchelli, S

    2009-01-30

    We present the first direct experimental bound on the total decay width of the top quark, Gamma(t), using 955 pb(-1) of the Tevatron's pp collisions recorded by the Collider Detector at Fermilab. We identify 253 top-antitop pair candidate events. The distribution of reconstructed top quark mass from these events is fitted to templates representing different values of the top quark width. Using a confidence interval based on likelihood-ratio ordering, we extract an upper limit at 95% C.L. of Gamma(t)<13.1 GeV for an assumed top quark mass of 175 GeV/c(2).