WorldWideScience

Sample records for toric lens orientation

  1. Toric intraocular lens orientation and residual refractive astigmatism: an analysis

    Directory of Open Access Journals (Sweden)

    Potvin R

    2016-09-01

    Full Text Available Rick Potvin,1 Brent A Kramer,2 David R Hardten,3 John P Berdahl4 1Science in Vision, Akron, NY, 2University of Iowa Carver College of Medicine, Iowa City, IA, 3Minnesota Eye Consultants, Minnetonka, MN, 4Vance Thompson Vision, Sioux Falls, SD, USA Purpose: To analyze intraocular lens (IOL orientation data from an online toric back-calculator (astigmatismfix.com for determining if differences were apparent by lens type.Methods: A retrospective review of astigmatismfix.com toric back-calculations that included IOL identification and intended orientation axis.Results: Of 12,812 total validated calculation records, 8,229 included intended orientation and lens identification data. Of the latter, 5,674 calculations (69% involved lenses oriented 5° or more from their intended position. Using estimated toric lens usage data, the percentage of lenses with orientation ≥5° from intended was 0.89% overall, but the percentage varied significantly between specific toric lens brands (P<0.05. The percentage of back-calculations related to lenses that were not oriented as intended was also statistically significantly different by lens brand (P<0.05. When IOLs were misoriented, they were significantly more likely to be misoriented in a counterclockwise direction (P<0.05. This was found to be due to a bias toward counterclockwise orientation observed with one specific brand, a bias that was not observed with the other three brands analyzed here.Conclusion: The percentage of eyes with lens orientation ≥5° from intended in the Toric Results Analyzer data set was <1% of toric IOLs in general, with the relative percentage of Tecnis® Toric IOLs significantly higher than AcrySof® Toric IOLs. Both of these had higher rates than the Staar® Toric and Trulign® Toric lenses, with the availability of higher Tecnis and AcrySof cylinder powers a likely contributing factor. The AcrySof Toric IOL appears to be less likely than the Tecnis Toric IOL to cause residual

  2. [Visual quality comparison after multifocal toric intraocular lens or monofocal toric intraocular lens implantation].

    Science.gov (United States)

    Feng, K; Guo, H K; Zhang, Y L; Wu, Z

    2017-04-11

    Objective: To compare visual quality and satisfaction after multifocal toric intraocular lens (Acrysof IQ Restor toric, ART) and monofocal toric intraocular lens implantation in patients. Methods: It was a prospective nonrandomized Phase Ⅲ clinical trial. Patients with age-related cataract and corneal astigmatism were enrolled and accepted phacoemulsification combined with implantation of intraocular lens (IOL) in Henan Provincial Eye Hospital during March 2013 to December 2014. Fifty-six cases were divided into two groups according to which IOL they chose. ART group included 28 cases (3l eyes) aged from 41.0 to 72.0 years, with an average age of 61.5 years; toric group included 28 cases (33 eyes) aged from 42.0 to 75.0 years, with an average age of 63.5 years. Three months postoperatively, uncorrected distance visual acuity (UDVA) at 5, 70, 40 cm, corrected distance, intermediate, and near visual acuities, defocus curve, residual refractive astigmatism, rotational stability of the IOL, contrast sensitivity and patientsatisfaction were evaluated. All data were processed by statistic package deal SPSS 16.0. Postoperative visual acuity, residual astigmatism, IOL axial rotation and contrast sensitivity were compared by independent samples t test; preoperative and postoperative corneal astigmatism were compared by paired t -test; spectacle independency and halo incidence were processed by χ(2) test; visual satisfaction score was analyzed by Mann-Whitney test. Results: At 3 months postoperatively, in ART group, UDVA was (0.04±0.05), UIVA was (0.24±0.15), UNVA was (0.20±0.24). While in Toric group, UDVA was (0.06±0.04), UIVA was (0.30±0.13), UNVA was (0.47±0.21). There was no significant difference in UDVA between two groups( t= 0.79, P= 0.433). But in ART group, UIVA and UNVA were markedly better than those in Toric group( t= 2.74, P= 0.008; t= 3.45, PART group and 2.50 D (+1.00--1.50 D) in the Toric group. Average postoperative residual astigmatism was (-0.45

  3. Scleral Fixation of a One-Piece Toric Intraocular lens

    Science.gov (United States)

    Emanuel, Matthew E.; Randleman, J. Bradley; Masket, Samuel

    2013-01-01

    Purpose To describe a novel technique for toric intraocular lens (IOL) repositioning and fixation in the absence of adequate capsular support Methods Case report and literature review Results Two cases are presented with scleral fixation of a one-piece toric IOL (SN6AT series, Alcon Inc.) In both cases, toric IOLs initially placed within the capsular bag became decentered due to poor capsular support and/or posterior capsule rupture. To avoid the potential complications of lens explantation and maintain the astigmatic benefits of the toric IOL, scleral fixation of the lenses was performed. The Hoffman technique was used to create reverse scleral pockets without conjunctival dissection. A 10-0 suture was used to capture and then secure the lens haptics in a lasso-type fashion. Sutures were then buried within the previously created scleral pockets. Both patients had well centered lenses postoperatively and have remained stable at last follow-up, up to thirty months postoperatively. Conclusion In the absence of adequate capsular support, scleral fixation is a viable option for one-piece toric IOL fixation to avoid IOL explanation PMID:23380416

  4. Foldable toric intraocular lens for astigmatism correction in cataract patients.

    Science.gov (United States)

    Mendicute, Javier; Irigoyen, Cristina; Aramberri, Jaime; Ondarra, Ana; Montés-Micó, Robert

    2008-04-01

    To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. Ophthalmology Service, Donostia Hospital, San Sebastián, Spain. This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having cataract surgery. Bilateral implantation of the AcrySof toric IOL was performed after phacoemulsification. The uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured. The UCVA was 20/40 or better in 93.3% of eyes and 20/25 or better in 66.6%. All eyes achieved 20/25 or better BCVA. The mean refractive cylinder decreased significantly after surgery from -2.34 D +/- 1.28 (SD) to -0.72 +/- 0.43 D (P<.01). Vector analysis of attempted versus achieved correction showed that 100% of eyes were within +/-1.00 D and 80% and 93.9% were within +/-0.50 D for J(0) and J(45), respectively. The mean toric IOL axis rotation was 3.63 +/- 3.11 degrees, with rotation less than 10 degrees in 96.7% of eyes. The results indicate that phacoemulsification and posterior chamber AcrySof toric IOL implantation is an effective option to correct preexisting astigmatism in cataract surgery. The AcrySof toric IOL showed good rotational stability.

  5. Fluctuation in visual acuity during soft toric contact lens wear.

    Science.gov (United States)

    Chamberlain, Paul; Morgan, Philip B; Moody, Kurt J; Maldonado-Codina, Carole

    2011-04-01

    To quantify changes in visual acuity (VA) with soft toric contact lenses as a result of lens movement and/or rotational instability caused by versional eye movements. A novel chart for vision assessment at near (40 cm) for soft toric contact lenses (VANT chart),consisting of a central, color-coded logMAR panel and eight peripheral letter targets set on a white background measuring 60 × 40 cm was constructed. In the developmental phase of the work, 10 subjects (20 eyes) wore 2 toric lenses in random order, and the impact of rapid and delayed eye versions in 8 directions of gaze on VANT acuity was investigated. In phase 2, 35 subjects (68 eyes) wore 4 toric lenses in random order, and a streamlined clinical protocol using the VANT chart was implemented. Standard assessments of toric lens fit and distance VA were also performed. Testing in the first phase showed no difference for change in VA for rapid vs. delayed version movements, (p = 0.17) but acuity reduction was greater for diagonal compared with horizontal/vertical versions (p = 0.06). As such, testing in phase 2 proceeded using rapid, diagonal versions only. In this second phase, there were differences for low-contrast distance VA measures between lens types (p = 0.02) and for both VANT baseline acuity (p = 0.03) and postversion acuity (p = 0.04), but no differences were found between lenses for magnitude of vision loss (p = 0.91), which was about one line. No relationship was established between the magnitude of vision loss and measured rotational stability (p = 0.75). This work has demonstrated that conventional approaches to measuring VA do not fully replicate the "real world" experience of soft toric lens wearers. The VANT chart has shown that VA is reduced immediately after versional eye movements and suggests that more dynamic methods of assessing visual performance should be considered for soft toric contact lens wearers, especially given the apparent inability of lens stability measurements to predict

  6. Toric implantable collamer lens for keratoconus

    Directory of Open Access Journals (Sweden)

    Mathew Kurian Kummelil

    2013-01-01

    Full Text Available Keratoconus is a progressive non-inflammatory thinning of the cornea that induces myopia and irregular astigmatism and decreases the quality of vision due to monocular diplopia, halos, or ghost images. Keratoconus patients unfit for corneal procedures and intolerant to refractive correction by spectacles or contact lenses have been implanted toric posterior chamber phakic intraocular lenses (PC pIOLs alone or combined with other surgical procedures to correct the refractive errors associated with keratoconus as an off label procedure with special informed consent from the patients. Several reports attest to the safety and efficacy of the procedure, though the associated corneal higher order aberrations would have an impact on the final visual quality.

  7. Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power

    Directory of Open Access Journals (Sweden)

    Davison JA

    2015-08-01

    Full Text Available James A Davison,1 Richard Potvin21Wolfe Eye Clinic, Marshalltown, IA, USA; 2Science in Vision, Akron, NY, USAPurpose: To determine whether the total corneal refractive power (TCRP value, which is based on measurement of both anterior and posterior corneal astigmatism, is effective for toric intraocular lens (IOL calculation with AcrySof® Toric IOLsPatients and methods: A consecutive series of cataract surgery cases with AcrySof toric IOL implantation was studied retrospectively. The IOLMaster® was used for calculation of IOL sphere, the Pentacam® TCRP 3.0 mm apex/ring value was used as the keratometry input to the AcrySof Toric IOL Calculator and the VERION™ Digital Marker for surgical orientation. The keratometry readings from the VERION reference unit were recorded but not used in the actual calculation. Vector differences between expected and actual residual refractive cylinder were calculated and compared to simulated vector errors using the collected VERION keratometry data.Results: In total, 83 eyes of 56 patients were analyzed. Residual refractive cylinder was 0.25 D or lower in 58% of eyes and 0.5 D or lower in 80% of eyes. The TCRP-based calculation resulted in a statistically significantly lower vector error (P<0.01 and significantly more eyes with a vector error ≤0.5 D relative to the VERION-based calculation (P=0.02. The TCRP and VERION keratometry readings suggested a different IOL toric power in 53/83 eyes. In these 53 eyes the TCRP vector error was lower in 28 cases, the VERION error was lower in five cases, and the error was equal in 20 cases. When the anterior cornea had with-the-rule astigmatism, the VERION was more likely to suggest a higher toric power and when the anterior cornea had against-the-rule astigmatism, the VERION was less likely to suggest a higher toric power.Conclusion: Using the TCRP keratometry measurement in the AcrySof toric calculator may improve overall postoperative refractive results

  8. Optical quality of toric intraocular lens implantation in cataract surgery

    Directory of Open Access Journals (Sweden)

    Xian-Wen Xiao

    2015-02-01

    Full Text Available AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system. METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of AcrySof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes, T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity (UDVA, corrected distance visual acuity (CDVA, residual refractive cylinder and intraocular lens (IOL axis rotation. Objective optical quality were measured using optical quality analysis system (OQAS Ⅱ®, Visiometrics, Spain, included the cutoff frequency of modulation transfer function (MTFcutoff, objective scattering index (OSI, Strehl ratio, optical quality analysis system value (OV 100%, OV 20% and OV 9% [the optical quality analysis system (OQAS values at contrasts of 100%, 20%, and 9%]. RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18±0.11 and 0.07±0.08 logMAR; the mean residual refractive cylinder was 0.50±0.29 D; the mean toric IOL axis rotation was 3.62±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV 9% were 22.862±5.584, 1.80±0.84, 0.155±0.038, 0.76±0.18, 0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%, OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different (P>0.05, except the residual refractive cylinder (PCONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of AcrySof toric IOL implantation. Implantation of an AcrySof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery.

  9. Spontaneous Rotation of a Toric Implantable Collamer Lens

    OpenAIRE

    Navas, Alejandro; Mu?oz-Ocampo, Mayeli; Graue-Hern?ndez, Enrique O.; G?mez-Bastar, Arturo; Ramirez-Luqu?n, Tito

    2010-01-01

    We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with –7.75 –4.25 × 0° and –8.25 –5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/...

  10. Multifocal Toric Intraocular Lens for Traumatic Cataract in a Child

    Directory of Open Access Journals (Sweden)

    Yanfeng Zeng

    2016-10-01

    Full Text Available A child suffering from traumatic cataract and corneal astigmatism of 2.14 D had a phacoemulsification operation and implantation of a ReSTOR Toric intraocular lens (IOL to correct the astigmatism. The primary outcome measurements were the uncorrected distance visual acuity (UDVA, uncorrected near vision at 40 cm, intraocular pressure, spherical equivalent refraction, residual astigmatism, corneal astigmatism, presence of unusual optical phenomena, and use of spectacles. At 7 months postoperatively, UDVA was maintained between 16/20 and 24/20, near vision was between J1 and J3, residual spherical refraction was 0–0.37 D, and residual refractive cylinder was between 0 and 0.67 D. A multifocal toric IOL can provide the possibility of satisfactory vision for both distant and near conditions without the use of spectacles to meet children’s needs when studying and doing sports. Additionally, binocular vision can be reconstructed. This intervention, therefore, seems to be a satisfactory alternative.

  11. Spontaneous Rotation of a Toric Implantable Collamer Lens

    Science.gov (United States)

    Navas, Alejandro; Muñoz-Ocampo, Mayeli; Graue-Hernández, Enrique O.; Gómez-Bastar, Arturo; Ramirez-Luquín, Tito

    2010-01-01

    We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with −7.75 −4.25 × 0° and −8.25 −5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 −4.50 × 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months' follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation. PMID:21151633

  12. Spontaneous Rotation of a Toric Implantable Collamer Lens

    Directory of Open Access Journals (Sweden)

    Alejandro Navas

    2010-11-01

    Full Text Available We present a case of toric implantable collamer lens (TICL spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA was 20/800 and 20/1200, respectively, with –7.75 –4.25 × 0° and –8.25 –5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 –4.50 × 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months’ follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation.

  13. Clinical study of AcrySof IQ Toric intraocular lens implantation to corneal correct astigmatism

    Directory of Open Access Journals (Sweden)

    Qian Wang

    2014-09-01

    Full Text Available AIM: To observe the clinical outcome of implanting AcrySof IQ Toric intraocular lens to correct corneal astigmatism in cataract surgery, and to evaluate the result and rotational stability of AcrySof IQ Toric after cataract surgery. METHODS: A retrospective study of 26 eyes in 21 cataract patients with corneal astigmatism. All patients implanted AcrySof IQ Toric intraocular lens. The preoperative and postoperative uncorrected visual acuity(UCVA, best corrected visual acuity(BCVA, preoperative corneal astigmatism, anticipated residual astigmatism, total astigmatism, postoperative residual astigmatism and Toric lens axis were detected and measured.RESULTS: All patients' visual acuity and best corrected visual acuity improved significantly. The mean refractive cylinder decreased significantly after surgery from(2.05±0.57D to(0.55±0.33D(t=13.574, Pt=1.149, P>0.05. Three months after surgery, there was no significant difference between preoperative(2.01±0.58D and postoperative(-1.89±0.53D corneal astigmatism(t=1.908, P>0.05. The rotation of intraocular lens were CONCLUSION: The AcrySof IQ Toric lens make cataract patients enjoy the better UCVA including good rotational stability in the correct of corneal astigmatism. The AcrySof IQ Toric implantation is an effective option for the correct of preexisting corneal astigmatism in cataract surgery.

  14. Clinical assessment of diclofenac sodium eye drops in toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Yan Luo

    2013-05-01

    Full Text Available AIM:To evaluate the application of diclofenac sodium eye drops in toric intraocular lens implantation. METHODS: From January 2011 to February 2012, 38 eyes of 37 patients, who underwent toric intraocular lens implantation in this hospital, were randomly divided into diclofenac sodium eye drops group(trial groupand control group. Patient's degree of cooperation during surgery and inflammation postoperation after 1 day, 3,7, days, 1 month and 3 months were evaluated. RESULTS: Patient's degree of cooperation during surgery in the trial group(1.53±0.62was significantly better than in the control group(2.40±0.88, P<0.05. Inflammation reaction was gentle in the trial group 1 day postoperatively. CONCLUSION: Diclofenac sodium eye drops used during toric intraocular lens implantation can obviously alleviate eye irritation, and increase the cooperation of patients.

  15. Toric Intraocular Lens Implantation for Correction of Astigmatism in Cataract Patients with Corneal Ectasia

    Directory of Open Access Journals (Sweden)

    Efstratios A. Parikakis

    2013-11-01

    Full Text Available Our purpose was to examine the long-term efficacy of toric intraocular lens (IOL implantation in cataract patients with high astigmatism due to corneal ectasia, who underwent phacoemulsification cataract surgery. Five eyes of 3 cataract patients with topographically stable keratoconus or pellucid macular degeneration (PMD, in which phacoemulsification with toric IOL implantation was used to correct high astigmatism, are reported. Objective and subjective refraction, visual acuity measurement and corneal topography were performed in all cases before and after cataract surgery. In all cases, there was a significant improvement in visual acuity, as well as refraction, which remained stable over time. Specifically, in subjective refraction, all patients achieved visual acuity from 7/10 to 9/10 with up to -2.50 cyl. Corneal topography also remained stable. Postoperative follow-up was 18-28 months. Cataract surgery with toric IOL implantation seems to be safe and effective in correcting astigmatism and improving visual function in cataract patients with topographically stable keratoconus or PMD.

  16. Correction of High Astigmatism after Penetrating Keratoplasty with Toric Multifocal Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-07-01

    Full Text Available After penetrating keratoplasty (PK, high astigmatism is often induced, being frequently about 4–6 dpt. According to the entity and typology of astigmatism, different methods of correction can be used. Selective suture removal, relaxing incisions, wedge resections, compression sutures, photorefractive keratectomy, and laser-assisted in situ keratomileusis can reduce corneal astigmatism and ametropia, but meanwhile they can cause a reduction in the corneal integrity and cause an over- or undercorrection. In case of moderate-to-high regular astigmatisms, the authors propose a toric multifocal intraocular lens (IOL implantation to preserve the corneal integrity (especially in PK after herpetic corneal leukoma keratitis. We evaluated a 45-year-old patient who at the age of 30 was subjected to PK in his left eye due to corneal leukoma herpetic keratitis, which led to high astigmatism (7.50 dpt cyl. 5°. The patient was subjected to phacoemulsification and customized toric multifocal IOL implantation in his left eye. The correction of PK-induced residual astigmatism with a toric IOL implantation is an excellent choice but has to be evaluated in relation to patient age, corneal integrity, longevity graft, and surgical risk. It seems to be a well-tolerated therapeutic choice and with good results.

  17. Customized toric intraocular lens implantation for correction of extreme corneal astigmatism due to corneal scarring

    Directory of Open Access Journals (Sweden)

    R Bassily

    2010-03-01

    Full Text Available R Bassily, J LuckOphthalmology Department, Royal United Hospital, Combe Park, Bath, UKAbstract: A 76-year-old woman presented with decreased visual function due to cataract formation. Twenty-five years prior she developed right sided corneal ulceration that left her with 10.8 diopters (D of irregular astigmatism at 71.8° (steep axis. Her uncorrected visual acuity was 6/24 and could only ever wear a balanced lens due to the high cylindrical error. Cataract surgery was planned with a custom designed toric intraocular lens (IOL with +16.0 D sphere inserted via a wound at the steep axis of corneal astigmatism. Postoperative refraction was -0.75/+1.50 × 177° with a visual acuity of 6/9 that has remained unchanged at six-week follow-up with no IOL rotation. This case demonstrates the value of high power toric IOLs for the correction of pathological corneal astigmatism.Keywords: intraocular lens, corneal ulceration, visual acuity, scarring

  18. Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Talita Shimoda

    2014-04-01

    Full Text Available Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC was -2.19 (SD: ± 0.53. After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001. Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence.

  19. Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Wojciech Lubiński

    2016-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes after uncomplicated cataract surgery with implantation of an aspheric toric intraocular lens (IOL during a 6-month follow-up. Methods. Prospective study including 27 consecutive eyes of 18 patients (mean age: 66.1±11.4 years with a visually significant cataract and corneal astigmatism ≥ 0.75 D and undergoing uncomplicated cataract surgery with implantation of the Tecnis ZCT toric IOL (Abbott Medical Optics. Visual, refractive, and keratometric outcomes as well as IOL rotation were evaluated during a 6-month follow-up. At the end of the follow-up, patient satisfaction and perception of optical/visual disturbances were also evaluated using a subjective questionnaire. Results. At 6 months after surgery, mean LogMAR uncorrected (UDVA and corrected distance visual acuity (CDVA were 0.19±0.12 and 0.14±0.10, respectively. Postoperative UDVA of 20/40 or better was achieved in 92.6% of eyes. Mean refractive cylinder decreased significantly from −3.73±1.96 to −1.42±0.88 D (p<0.001, while keratometric cylinder did not change significantly (p=0.44. Mean absolute IOL rotation was 1.1±2.4°, with values of more than 5° in only 2 eyes (6.9%. Mean patient satisfaction score was 9.70±0.46, using a scale from 0 (not at all satisfied to 10 (very satisfied. No postoperative optical/visual disturbances were reported. Conclusion. Cataract surgery with implantation of the Tecnis toric IOL is an effective method of refractive correction in eyes with corneal astigmatism due to the good IOL positional stability, providing high levels of patient’s satisfaction.

  20. AcrySof toric intraocular lens for post-keratoplasty astigmatism

    Directory of Open Access Journals (Sweden)

    Nishant Gupta

    2012-01-01

    Full Text Available We report a 63-year-old male who had undergone left eye optical penetrating keratoplasty for central leucomatous corneal opacity 10 years earlier. The eye had clear donor graft with residual astigmatism of −6.50 diopter cylinder (DC at 30°. The patient underwent clear corneal phacoemulsification with implantation of +6.0 D spherical equivalent AcrySof SN60T9 intraocular lens (IOL. Postoperatively, at 10 months, the patient had distance corrected visual acuity of 20/30 with −2.00 DC at 20°. AcrySof toric IOL offers an effective treatment option for post-keratoplasty high corneal astigmatism in patients with cataract.

  1. Microincision Hydrophobic Acrylic Aspheric Toric Intraocular Lens for Astigmatism and Cataract Correction.

    Science.gov (United States)

    Bissen-Miyajima, Hiroko; Negishi, Kazuno; Hieda, Osamu; Kinoshita, Shigeru

    2015-06-01

    To evaluate the efficacy and safety of a new acrylic one-piece toric intraocular lens (IOL). This prospective multicenter clinical trial included 93 eyes of 61 patients that were implanted with a hydrophobic acrylic toric IOL from 2010 to 2012 and followed for 1 year. This IOL uses the platform of a microincision one-piece aspheric IOL, the NY-60 IOL (HOYA, Tokyo, Japan), with three increments in cylindrical power (NHT15, 1.5 diopters [D]; NHT23, 2.25 D; and NHT30, 3.0 D). The inclusion criterion was preoperative corneal astigmatism from 0.75 to 3.00 D. The primary endpoint was uncorrected distance visual acuity (UDVA) of 0.0 logMAR (20/20 Snellen) or better 6 months postoperatively. In addition to UDVA, corrected distance visual acuity (CDVA), residual astigmatism, stability of the IOL alignment, need of realignment, and the rate of Nd:YAG laser capsulotomy were evaluated up to 1 year postoperatively. Errors in astigmatic correction were assessed using Alpin's vector analysis. The primary endpoint was achieved in 54.8% of eyes. One year postoperatively, the logMAR UDVAs were 0.02 ± 0.13, 0.05 ± 0.17, and 0.09 ± 0.14 with models NHT15, NHT23, and NHT30, which corresponds to 0.96 (19/20 Snellen), 0.89 (18/20 Snellen), and 0.82 (16/20 Snellen), respectively. One year postoperatively, the residual astigmatism was 0.66 ± 0.58 D. In each evaluation, the mean absolute change in the position of the axis mark was between 1.93° and 2.32°. Three eyes required repositioning of the IOL axis and 2 eyes received Nd:YAG laser capsulotomy. The correction error showed an undercorrection with against-the-rule astigmatism and overcorrection with with-the-rule astigmatism. The new one-piece toric IOL provided desirable clinical outcomes and stability in eyes with corneal astigmatism. Copyright 2015, SLACK Incorporated.

  2. Axis alignment and rotational stability after implantation of the toric implantable collamer lens for myopic astigmatism.

    Science.gov (United States)

    Hashem, Ayman N; El Danasoury, Alaa M; Anwar, Hamed M

    2009-10-01

    To assess axis alignment and stability of the Toric Implantable Collamer Lens (TICL; STAAR Surgical Co) over time. Thirty-five consecutive eyes of 19 patients received the TICL for treatment of myopic astigmatism. Manifest refraction spherical equivalent (MRSE) and manifest refractive cylinder were measured preoperatively and at 3 months postoperatively. The axis alignment of the TICL was measured using the internal OPD map obtained with the OPD-Scan II (NIDEK Co Ltd). Mean refractive cylinder was reduced from 2.80+/-1.45 diopters (D) preoperatively to 0.63+/-0.75 D at 3 months postoperatively; MRSE was -7.61+/-4.02 D preoperatively and -0.14+/-0.38 D at 3 months. Mean absolute value of the measured axis misalignment from baseline (day 1) to 1 month was 2.90+/-2.11 degrees and from 1 month to 3 months was 4.6+/-11.2 degrees. Mean absolute value of the measured changes in axis misalignment from baseline to 3 months was 2.68+/-2.11 degrees (after excluding one eye that required repositioning due to TICL rotation). At 3 months postoperatively, 96.8% (30/31) eyes had axis misalignment. The TICL showed minimal axis misalignment after implantation and remained stable 3 months postoperatively. Copyright 2009, SLACK Incorporated.

  3. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation - Our experience.

    Science.gov (United States)

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Cataract services, Shroff Eye Centre, New Delhi, India. Case series. This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was -0.04 (SD = 0.76). We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.

  4. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

    Science.gov (United States)

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Purpose Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Setting Cataract services, Shroff Eye Centre, New Delhi, India. Design Case series. Method This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. Results The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76). Conclusion We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery. PMID:26586976

  5. Clinical outcomes with toric intraocular lenses planned using an optical low coherence reflectometry ocular biometer with a new toric calculator.

    Science.gov (United States)

    Gundersen, Kjell G; Potvin, Richard

    2016-01-01

    To prospectively evaluate postoperative clinical outcomes with implantation of toric intraocular lenses (IOLs) using preoperative keratometry from an optical low coherence reflectometry (OLCR) ocular biometer (Lenstar ® LS900) and the built-in Barrett toric calculator. A prospective observational study recruited one or both eyes of subjects who underwent uncomplicated cataract surgery with toric IOL implantation using OLCR biometery data and the Barrett toric IOL calculator for toric IOL planning. Data were collected at the preoperative, operative, 1-day and 2-month postoperative visits. The primary outcome measure was the manifest refractive astigmatism magnitude at 2 months. The secondary outcome measures included the manifest refraction, corneal keratometry, and distance visual acuity (corrected and uncorrected). The results obtained with the Barrett toric calculator were compared with simulated results based on the toric calculators designed for the IOLs being used. Data from 98 eyes of 54 subjects were available for analysis. In the 74 eyes with postoperative lens orientation as planned, and sufficient IOL cylinder power to correct subjects' measured astigmatism, 77% of eyes (57/74) had 0.5 diopter (D) or less refractive cylinder 2 months postoperatively, while 89% (66/74) had 0.75 D or less. Simulated results after adjusting actual IOL orientation to the planned orientation suggested that the Barrett calculator would result in postoperative residual astigmatism about 0.2 D lower than that expected with standard calculators. Use of the Barrett toric calculator with biometry data from the Lenstar LS900 biometer for toric IOL planning in a clinical setting resulted in significantly lower levels of residual refractive cylinder than might be expected with standard calculators. Postoperative lens orientation and variability in the measurement of corneal astigmatism pre- and postoperatively appear to be important limiting factors in toric IOL outcomes.

  6. Functional and refractive results after one month of AcrySof toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Francisco Alba-Bueno

    2011-04-01

    Conclusions: The implantation of SN60T toric IOL in patients with CA higher than 0.75 D is a safe, predictable and effective way of reducing refractive astigmatism in patients undergoing cataract surgery.

  7. Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker

    Directory of Open Access Journals (Sweden)

    Javed Hussain Farooqui

    2016-05-01

    Full Text Available AIM: To compare the accuracy of two different methods of preoperative marking for toric intraocular lens (IOL implantation, bubble marker versus pendulum marker, as a means of establishing the reference point for the final alignment of the toric IOL to achieve an outcome as close as possible to emmetropia. METHODS: Toric IOLs were implanted in 180 eyes of 110 patients. One group (55 patients had preoperative marking of both eyes done with bubble marker (ASICO AE-2791TBL and the other group (55 patients with pendulum marker (Rumex(3-193. Reference marks were placed at 3-, 6-, and 9-o'clock positions on the limbus. Slit-lamp photographs were analyzed using Adobe Photoshop (version 7.0. Amount of alignment error (in degrees induced in each group was measured. RESULTS: Mean absolute rotation error in the preoperative marking in the horizontal axis was 2.42±1.71 in the bubble marker group and 2.83±2.31in the pendulum marker group (P=0.501. Sixty percent of the pendulum group and 70% of the bubble group had rotation error ≤3 (P=0.589, and 90% eyes of the pendulum group and 96.7% of the bubble group had rotation error ≤5 (P=0.612. CONCLUSION: Both preoperative marking techniques result in approximately 3 of alignment error. Both marking techniques are simple, predictable, reproducible and easy to perform.

  8. Comparing the Zeiss Callisto Eye and the Alcon Verion Image Guided System Toric Lens Alignment Technologies.

    Science.gov (United States)

    Hura, Arjan S; Osher, Robert H

    2017-07-01

    To compare the alignment meridian generated by the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA) and the Alcon Verion Image Guided System (Alcon Laboratories, Inc., Fort Worth, TX). In this retrospective comparative evaluation of technology, intraoperative images were captured at different steps in the same surgery, allowing the comparison of the guidance lines generated by the Verion system to the parallel guidance lines generated by the Callisto Eye system. Measurements of each hemi-meridian were quantified using Adobe Photoshop 2015 CC software (Adobe Systems, San Jose, CA). The numbers of degrees separating these alignment meridians were calculated, entered into a database, and analyzed. The authors found that of 98 captured images of 16 eyes, the two technologies were identical in 0 eyes (θ 1 = θ 2 = 0), similar by 3° in 52 (53%) captured images (θ 1 ≠ θ 2 ≠ 0), and different by at least 3° in 46 (47%) captured images (θ 1 ≠ θ 2 ≠ 0). The target meridians were superimposed, the target lines were minimally separated, and the target lines were dissimilar. It was noted that some intraoperative variation occurred from measurement to measurement. Within the small group of 16 cases of routine toric lens implantation in this study, the absolute average number of degrees of misalignment between the Verion and Callisto Eye systems was 3.355 for θ 1 and 3.838 for θ 2 . On average, the intraoperative variation termed "drift" was noted to be 3.963° for θ 1 , and 4.557° for θ 2 . The authors found that small deviations were frequent when comparing two sophisticated technologies. Although deviations greater than 3° occurred in less than 47% of captured images from 16 eyes, smaller but significant variations of less than 3° occurred in 53% of captured images from 16 eyes. It was rare to identify a large deviation. However, the authors identified "drift" in the same eye when measurements were taken at different times. The results indicate that the two

  9. Rotational stability and visual quality in eyes with Rayner toric intraocular lens implantation.

    Science.gov (United States)

    Alberdi, Txomin; Macías-Murelaga, Beatriz; Bascarán, Lucía; Goñi, Nahia; de Arregui, Sandra Sáez; Mendicute, Javier

    2012-10-01

    To assess astigmatic reduction and rotational stability of Rayner T-flex toric intraocular lenses (IOL) (573T and 623T; Rayner Intraocular Lenses Ltd) in a series of cataract surgery patients with corneal astigmatism >1.50 diopters (D). This prospective, observational study included 27 eyes from 22 consecutive patients with pre-operative regular corneal astigmatism ≥1.50 D in which Rayner T-flex toric IOL implantation was performed after phacoemulsification. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual refractive sphere, residual keratometric and refractive cylinder, and deviation from attempted toric IOL axis were measured. Mean UDVA 3 months after surgery was 0.1042±0.1290 with 20/40 or better in 96% of eyes and 20/25 or better in 52% of eyes. Mean refractive postoperative sphere was 0.25±0.37 D and mean refractive postoperative cylinder was 0.52±0.63 D. Vector analysis of attempted versus achieved visual correction showed that 100% of eyes were within ±1.00 D and 87% of eyes were within ±0.50 D. Mean change in keratometric astigmatism was 0.54±1.33 for J(0) and -0.24±1.17 for J(45) (P>.05). Twenty-five (92.6%) eyes had IOL rotation <10°. Rayner T-flex toric IOL implantation is an effective and reliable option to correct preexisting astigmatism in cataract surgery. Copyright 2012, SLACK Incorporated.

  10. [Evaluation of visual performance after implantation of a double C-Loop toric intraocular lens].

    Science.gov (United States)

    Chassain, C

    2014-09-01

    This study aims to demonstrate the safety and the efficacy of the Ankoris posterior chamber intraocular lens to correct corneal astigmatism at the time of cataract surgery. In this retrospective study, 52 eyes among the first 64 consecutive ones implanted with the Ankoris met the inclusion criteria. The retrospective analysis of these cases consisted mainly of the determination of the improvement in visual acuity and postoperative refraction. The analysis of the astigmatism correction itself was carried out by the Alpins method. The rotational stability of the implant was analyzed by the difference between the IOL orientation after one day and 3 months. The safety index, defined as the postoperative divided by preoperative best visual acuity, was greater than one in all cases, with a mean of 1.96. The ratio of the postoperative uncorrected visual acuity with the preoperative best-corrected acuity was 1.72. The final postoperative astigmatism was -0.40 ± 0.28 D. The percentage of astigmatism corrected was 99.3%. The error vector amplitude was 0.1 D with a nearly null orientation. The mean rotation was 2.16 ± 1.95°. The Ankoris IOL demonstrates, in this relatively large cohort, all necessary elements to establish that the IOL was able to correct corneal astigmatism at the same time as cataract surgery. Copyright © 2014. Published by Elsevier Masson SAS.

  11. Clinical outcomes with toric intraocular lenses planned using an optical low coherence reflectometry ocular biometer with a new toric calculator

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-11-01

    Full Text Available Kjell G Gundersen,1 Richard Potvin21IFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Akron, NY, USAPurpose: To prospectively evaluate postoperative clinical outcomes with implantation of toric intraocular lenses (IOLs using preoperative keratometry from an optical low coherence reflectometry (OLCR ocular biometer (Lenstar® LS900 and the built-in Barrett toric calculator.Patients and methods: A prospective observational study recruited one or both eyes of subjects who underwent uncomplicated cataract surgery with toric IOL implantation using OLCR biometery data and the Barrett toric IOL calculator for toric IOL planning. Data were collected at the preoperative, operative, 1-day and 2-month postoperative visits. The primary outcome measure was the manifest refractive astigmatism magnitude at 2 months. The secondary outcome measures included the manifest refraction, corneal keratometry, and distance visual acuity (corrected and uncorrected. The results obtained with the Barrett toric calculator were compared with simulated results based on the toric calculators designed for the IOLs being used.Results: Data from 98 eyes of 54 subjects were available for analysis. In the 74 eyes with postoperative lens orientation as planned, and sufficient IOL cylinder power to correct subjects’ measured astigmatism, 77% of eyes (57/74 had 0.5 diopter (D or less refractive cylinder 2 months postoperatively, while 89% (66/74 had 0.75 D or less. Simulated results after adjusting actual IOL orientation to the planned orientation suggested that the Barrett calculator would result in postoperative residual astigmatism about 0.2 D lower than that expected with standard calculators.Conclusion: Use of the Barrett toric calculator with biometry data from the Lenstar LS900 biometer for toric IOL planning in a clinical setting resulted in significantly lower levels of residual refractive cylinder than might be expected with standard calculators

  12. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace.

    Science.gov (United States)

    Farooqui, Javed Hussain; Sharma, Mansi; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2017-01-01

    The aim of this study is to compare two different methods of analysis of preoperative reference marking for toric intraocular lens (IOL) after marking with an electronic marker. Cataract and IOL Implantation Service, Shroff Eye Centre, New Delhi, India. Fifty-two eyes of thirty patients planned for toric IOL implantation were included in the study. All patients had preoperative marking performed with an electronic preoperative two-step toric IOL reference marker (ASICO AE-2929). Reference marks were placed at 3-and 9-o'clock positions. Marks were analyzed with two systems. First, slit-lamp photographs taken and analyzed using Adobe Photoshop (version 7.0). Second, Tracey iTrace Visual Function Analyzer (version 5.1.1) was used for capturing corneal topograph examination and position of marks noted. Amount of alignment error was calculated. Mean absolute rotation error was 2.38 ± 1.78° by Photoshop and 2.87 ± 2.03° by iTrace which was not statistically significant ( P = 0.215). Nearly 72.7% of eyes by Photoshop and 61.4% by iTrace had rotation error ≤3° ( P = 0.359); and 90.9% of eyes by Photoshop and 81.8% by iTrace had rotation error ≤5° ( P = 0.344). No significant difference in absolute amount of rotation between eyes when analyzed by either method. Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag.

  13. Toric topology

    CERN Document Server

    Buchstaber, Victor M

    2015-01-01

    This book is about toric topology, a new area of mathematics that emerged at the end of the 1990s on the border of equivariant topology, algebraic and symplectic geometry, combinatorics, and commutative algebra. It has quickly grown into a very active area with many links to other areas of mathematics, and continues to attract experts from different fields. The key players in toric topology are moment-angle manifolds, a class of manifolds with torus actions defined in combinatorial terms. Construction of moment-angle manifolds relates to combinatorial geometry and algebraic geometry of toric v

  14. Implantation of a Multifocal Toric Intraocular Lens after Radial Keratotomy and Cross-Linking with Hyperopia and Astigmatism Residues: A Case Report

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-08-01

    Full Text Available Radial keratotomy is a refractive surgical technique, widely used in the 80s and early 90s to correct myopia and astigmatism, but now overcome by more recent laser techniques. Important consequences, often in patients with more than 45 years of age, are progressive hyperopic shift and/or an increase in corneal astigmatism, whose main cause seems to be an increase in the curvature radius of the central portion of the cornea. This seems to be due to radial keratotomy incisions – with the consequent need for cross-linking – intraocular pressure, and corneal biomechanical parameters. The authors propose phacoemulsification with a customized multifocal toric intraocular lens implantation to correct the induced shift and hyperopic astigmatism. A decent postoperative visual acuity was observed with good patient satisfaction. A specific protocol must be applied to optimize the correct diagnosis, presurgical evaluation and postsurgical outcomes that are to be maintained over time, without regressions.

  15. Comparison of Visual, Refractive and Aberration Measurements of INTACS versus Toric ICL Lens Implantation; A Four-year Follow-up.

    Science.gov (United States)

    Ramin, Shahrokh; Sangin Abadi, Azad; Doroodgar, Farideh; Esmaeili, Mehrdad; Niazi, Faizollah; Niazi, Sana; Alinia, Cyrus; Golestani, Yaser; Taj Abadi, Reza

    2018-01-01

    This study was performed to evaluate the visual, refractive, and aberration measurement results of 2 implants, including Intacs Intracorneal Ring Segments (ICRS) and phakic Toric Implantable Collamer Lens (TICL), in patients with moderate Keratoconus (KCN). In this retrospective cross-sectional study, 30 patients with KCN with a mean age of 29.83 years were included in 2 groups, including the Intacs Intracorneal Ring Segments (ICRS) group and the phakic Toric Implantable Collamer Lens (TICL) group. Preoperative data as well as 6-month, 1-, 2-, 3- and 4-year follow-up data after the operation were collected and analyzed with the SPSS software (ver. 23.0, SPSS, Inc., Chicago, IL), using the paired t-test, independent t-test, repeated measures Analysis of Variance (ANOVA), and one-way ANOVA. This study included 30 patients with KCN with a mean age of 29.83 years and range of 25 to 35 years, including 17 males with a mean age of 30.11 years and 13 female with a mean age of 29.25 years. Except for preoperative Uncorrected Distance Visual Acuity (UCDVA), Spherical Equivalent (SE) and astigmatism, there was a significant difference between the 2 groups regarding other variables. The TICL group had a significantly better UCDVA and Best Corrected Distance Visual Acuity (BCDVA) in all post-operative follow-ups, and SE and astigmatism values were significantly lower in all post-operative follow-ups when compared with the ICRS group. There was a significant reduction in corneal and total coma as well as internal trefoil aberrations (P<0.01, P<0.01, and P=0.014, respectively) in the ICRS group, and TICL led to a significant reduction in internal trefoil aberration with P<0.03. Comparison of the 2 groups revealed a significant difference in corneal spherical (P<0.01) and total coma (P=0.02) aberrations and no significant differences in other HOA. Both ICRS and TICL are useful in patients with moderate KCN. However, TICL appears to have more stable and predictable vision results.

  16. Computerized calculation scheme for toric intraocular lenses.

    Science.gov (United States)

    Langenbucher, Achim; Seitz, Berthold

    2004-06-01

    While a number of intraocular lens (IOL) power prediction formulae are well established for determination of spherical lenses, no common strategy has been published for the computation of toric IOLs. The purpose of this study is to describe a paraxial computing scheme for tracing an axial pencil of rays through the 'optical system eye' containing astigmatic refractive surfaces with their axes at random. The capabilities of this computing scheme are demonstrated with clinical examples. Based on a schematic model eye with spherocylindric surfaces, we use two alternative notations for description of vergences or prescriptions: (1) standard notation (refraction in both cardinal meridians and axis), and (2) component notation (spherical equivalent and cylindric component in 0 degrees and 45 degrees. Refractive surfaces are added to the vergence in component notation, whereas the transformation of the vergence through media is performed in the standard notation for both cardinal meridians. For calculation of the toric lens implant, a pencil of rays is traced through the spectacle and the cornea to the estimated lens position as well as backwards from the retina to the estimated lens position. For calculation of residual spectacle refraction, a pencil of rays is traced backwards from the retina through the toric lens implant and the cornea to the spectacle plane. In example 1 we calculate a 'thin toric lens' for compensation of a corneal astigmatism to achieve a spherical target refraction. In example 2 we compute a 'thick toric lens', which has to compensate for an oblique corneal astigmatism and rotate the spectacle cylinder to the against the rule position to enhance near vision. In example 3 we estimate the residual refraction at the corneal plane after implantation of a thick toric lens, when the cylinder of the lens implant is compensating the corneal cylinder in part and the axis of implantation is not fully aligned with the axis of the corneal astigmatism. This

  17. Toric Vaisman manifolds

    Science.gov (United States)

    Pilca, Mihaela

    2016-09-01

    Vaisman manifolds are strongly related to Kähler and Sasaki geometry. In this paper we introduce toric Vaisman structures and show that this relationship still holds in the toric context. It is known that the so-called minimal covering of a Vaisman manifold is the Riemannian cone over a Sasaki manifold. We show that if a complete Vaisman manifold is toric, then the associated Sasaki manifold is also toric. Conversely, a toric complete Sasaki manifold, whose Kähler cone is equipped with an appropriate compatible action, gives rise to a toric Vaisman manifold. In the special case of a strongly regular compact Vaisman manifold, we show that it is toric if and only if the corresponding Kähler quotient is toric.

  18. Outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of the Toric implantable collamer lens for high myopic astigmatism.

    Science.gov (United States)

    Sheng, Xun-Lun; Rong, Wei-Ning; Jia, Qin; Liu, Ya-Ni; Zhuang, Wen-Juan; Gu, Qing; Sun, Yan; Pan, Bo; Zhu, De-Jun

    2012-01-01

    To assess the visual outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of Toric implantable collamer lens (TICL) for the correction of high myopic astigmatism. In this prospective, nonrandomized clinical study, 54 consecutive eyes of 29 patients with high myopic astigmatism received TICL implantation. To evaluate postoperative axis deviation from the intended axis, a digital anterior segment photograph was taken. The ultrasound biomicroscopy(UBM) was used to observe footplate-position. After mean follow-up of 8.6 months, mean manifest refractive cylinder (MRC) decreased 79.3% from (-1.88±1.49)D preoperatively to (0.39±0.61)D postoperatively. MRC within 1.00 D occurred in 68.5% (37/54) of eyes, whereas 48.1% (26/54) had MRC within 0.50 D. Mean manifest refraction spherical equivalent (MRSE) changed from (-12.08±4.22)D preoperatively to (-0.41±0.61)D postoperatively. Uncorrected binocular vision of 20/20 or better occurred in 72.2% (39/54) of patients compared with binocular best-corrected visual acuity (BCVA) of 20/20 or better in 44.4% (24/54) preoperatively. The mean difference between intended and achieved TICL axes was (6.96±8.37)°. Footplates of TICLs were in the ciliary sulcus in 22 eyes (46.3%), below the ciliary sulcus in 32 eyes (53.7%). The angle of TICL rotation had significant correlation with the footplates-position (t=2.127; P=0.045) and the postoperative TICL vaulting (r=-0.516; P=0.000). The results of our study further support the safety, efficacy and predictability of TICL for the correct high myopic astigmatism. The footplate-position of TICL and vault value should be taken into consideration as two possible risks factors for TICL rotation.

  19. Comparison of Two Toric IOL Calculation Methods

    Directory of Open Access Journals (Sweden)

    C. Kern

    2018-01-01

    Full Text Available Purpose. To compare two calculators for toric intraocular lens (IOL calculation and to evaluate the prediction of refractive outcome. Methods. Sixty-four eyes of forty-five patients underwent cataract surgery followed by implantation of a toric intraocular lens (Zeiss Torbi 709 M calculated by a standard industry calculator using front keratometry values. Prediction error, median absolute error, and refractive astigmatism error were evaluated for the standard calculator. The predicted postoperative refraction and toric lens power values were evaluated and compared after postoperative recalculation using the Barrett calculator. Results. We observed a significant undercorrection in the spherical equivalent (0.19 D by using a standard calculator (p≤0.05. According to the Baylor nomogram and the refractive influence of posterior corneal astigmatism (PCA, undercorrection of the cylinder was lower for patients with WTR astigmatism, because of the tendency of overcorrection. An advantage of less residual postoperative SE, sphere, and cylinder for the Barrett calculator was observed when retrospectively comparing the calculated predicted postoperative refraction between calculators (p≤0.01. Conclusion. Consideration of only corneal front keratometric values for toric lens calculation may lead to postoperative undercorrection of astigmatism. The prediction of postoperative refractive outcome can be improved by using appropriate methods of adjustment in order to take PCA into account.

  20. Toric intraocular lenses--theory, matrix calculations, and clinical practice.

    Science.gov (United States)

    Langenbucher, Achim; Viestenz, Anja; Szentmáry, Nóra; Behrens-Baumann, Wolfgang; Viestenz, Arne

    2009-07-01

    To describe 1) how to determine toric (posterior chamber) intraocular lenses (IOLs) with standard formulas, 2) a matrix-based calculation scheme for determining toric IOLs using 4x4 matrices, 3) a method to determine residual refraction after implantation of an arbitrary toric lens, and 4) to address clinical aspects. Formulas and metrics are reviewed for determining IOL power and residual refraction after toric IOL implantation. From 4x4 refraction and translation matrices characterizing refractive surfaces and interspaces between refractive surfaces, a system matrix is determined characterizing the entire optical system paraxially. Toric posterior chamber IOLs are determined by solving a linear equation system. In a second step, the same methodology is used for estimation of the residual refraction at the spectacle plane after implantation of an arbitrary toric lens. The methodology is applied to working examples, and the calculation procedure is described in a step-by-step approach. A straight-forward en bloc concept is demonstrated for determination of toric IOLs and estimation of the residual refraction. The applicability is shown in working examples, and clinical aspects such as rotation of the lens implant are addressed.

  1. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace

    Directory of Open Access Journals (Sweden)

    Javed Hussain Farooqui

    2017-01-01

    CONCLUSIONS: Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag.

  2. Visual Outcomes after Phacoemulsification with AcrySof Toric ...

    African Journals Online (AJOL)

    Introduction: To study the visual outcome of AcrySof toric intraocular lens (IOL) implantation in patients having cataract associated with astigmatism. Materials and Methods: In this prospective interventional case series, 30 eyes of 28 patients with preoperative astigmatism of 1.5–4.5D cylinder underwent phacoemulsification ...

  3. Visual Outcomes after Phacoemulsification with AcrySof Toric ...

    African Journals Online (AJOL)

    2016-12-13

    Dec 13, 2016 ... Introduction: To study the visual outcome of AcrySof toric intraocular lens (IOL) implantation in patients having cataract associated with astigmatism. ... The outcome measures were uncorrected visual acuity (UCVA), refractive cylinder, and degree of. IOL rotation. ..... Financial support and sponsorship.

  4. Spatial pattern of cell geometry and cell-division orientation in zebrafish lens epithelium

    Directory of Open Access Journals (Sweden)

    Toshiaki Mochizuki

    2014-09-01

    Full Text Available Cell proliferation is a key regulator of tissue morphogenesis. We examined cell proliferation and cell division in zebrafish lens epithelium by visualizing cell-cycle phases and nuclear positions, using fluorescent-labeled geminin and histone proteins. Proliferation was low in the anterior region of lens epithelium and higher in the marginal zone anterior to the equator, suggesting that the proliferation zone, called the germinative zone, is formed in zebrafish lens. Interestingly, cell-division orientation was biased longitudinally in the anterior region, shifted from longitudinal to circumferential along the anterior–posterior axis of lens sphere, and was biased circumferentially in the peripheral region. These data suggest that cell-division orientation is spatially regulated in zebrafish lens epithelium. The Hertwig rule indicates that cells tend to divide along their long axes. Orientation of long axes and cell division were biased similarly in zebrafish lens epithelium, suggesting that cell geometry correlates with cell-division orientation. A cell adhesion molecule, E-cadherin, is expressed in lens epithelium. In a zebrafish e-cadherin mutant, the long axes and cell-division orientation were shifted more longitudinally. These data suggest that E-cadherin is required for the spatial pattern of cell geometry and cell-division orientation in zebrafish lens epithelium.

  5. Refractive astigmatism and the toricity of ocular components in human infants.

    Science.gov (United States)

    Mutti, Donald O; Mitchell, G Lynn; Jones, Lisa A; Friedman, Nina E; Frane, Sara L; Lin, Wendy K; Moeschberger, Melvin L; Zadnik, Karla

    2004-10-01

    Many studies have characterized astigmatism in infancy, but few have been longitudinal or contained ocular component data. This study characterized the frequency, orientation, and longitudinal change with age of infant astigmatism. Additional factors investigated were the influence of early astigmatism on emmetropization and its relation to corneal and lenticular toricity. Three hundred two infants were enrolled in the study. Of these, 298 provided data for at least one visit at 3 +/- 1 months, 9 +/- 1 months, 18 +/- 2 months, and 36 +/- 3 months. Testing included cycloplegic retinoscopy (cyclopentolate 1%), video-based keratophakometry, and ultrasonography over the closed eyelid. Astigmatism > or =1.00 DC was common at 3 months of age (41.6%) but decreased in prevalence to 4.1% by 36 months (p < 0.0001). The most common orientation was with-the-rule at 3 months (37.0% compared with 2.7% for against-the-rule) but against-the-rule at 36 months (3.2% compared with 0.9% for with-the-rule). Most of the change in the average value of the horizontal/vertical component of astigmatism (J0) occurred between 3 and 9 months (-0.26 +/- 0.36 D; p < 0.0001) with no significant change between 9 and 36 months (-0.05 +/- 0.36 D; p=0.09). Spherical equivalent refractive error was not correlated with J0 at 3 and 9 months (R=0.002, p=0.48 and R=0.001, p=0.56, respectively). The two were only weakly correlated at 18 and 36 months (R=0.06 for each age, p <0.0001, p=0.0002, respectively). Changes in spherical equivalent between 3 and 9 months were unrelated to either the initial value of J0 (partial R for J0=0.0001; p=0.85) or the change in J0 (partial R for change in J0=0.0031; p=0.31). Across all the ages, corneal toricity was with-the-rule, and lenticular toricity was against-the-rule (produced by the toricity of the posterior lens surface). The cornea and anterior lens surface became more spherical with age, contributing to the shift away from with-the-rule refractive astigmatism

  6. Comparative analysis of the visual performance after implantation of the toric implantable collamer lens in stable keratoconus: a 4-year follow-up after sequential procedure (CXL+TICL implantation).

    Science.gov (United States)

    Doroodgar, Farideh; Niazi, Feazollah; Sanginabadi, Azad; Niazi, Sana; Baradaran-Rafii, Alireza; Alinia, Cyrus; Azargashb, Eznollah; Ghoreishi, Mohammad

    2017-01-01

    To report on 4-year postoperative visual performance with the toric implantable collamer lens (TICL) for stable keratoconus after sequential procedure (corneal collagen crosslinking plus TICL implantation). Forty eyes of 24 patients with stable keratoconus with myopia between 0.00 and -18.00 dioptres (D) and astigmatism between 1.25 and 8.00 D were evaluated in this prospective interventional study (https://clinicaltrials.gov/ct2/show/NCT02833649). We evaluated refraction, visual outcomes, astigmatic changes analysed by Alpins vector, contrast sensitivity, aberrometry, modulation transfer functions (MTFs), defocus curve, and operative and postoperative complications. At 4-year follow-up, 45% had 20/20 vision or better and 100% had 20/40 or better uncorrected visual acuity (UCVA). Vector analysis of refractive astigmatism shows that the surgically induced astigmatism (SIA) (3.20±1.46 D) was not significantly different from the target induced astigmatism (TIA) (3.14±1.42 D) (p=0.620). At 4 years postoperatively, none of the eyes showed a decrease in UCVA, in contrast to 24 eyes in which UCVA was increased by ≥1 lines, with contrast sensitivity and improvement in total aberrations and MTF value at 5 per degree (*p=0.004) after TICL implantation. The cumulative 4-year corneal endothelial cell loss was ≤5%. No patients reported dissatisfaction. At the end of follow-up, the vault was 658±54.33m (range, 500-711) and the intraocular pressure was 11.7±2.08 mm Hg. Occurrences of glare and night-driving troubles diminished after TICL surgery. The results from this standardised clinical investigation support TICL implantation from clinical and optical viewpoints in patients with stable keratoconus. NCT02833649, Pre-results.

  7. Correção do astigmatismo irregular com lente intraocular tórica em um paciente com catarata e degeneração marginal pelúcida: relato de caso Toric intraocular lens implantation for cataract and irregular astigmatism related to pellucid marginal degeneration: case report

    Directory of Open Access Journals (Sweden)

    Ana Luiza Biancardi

    2012-12-01

    Full Text Available A degeneração marginal pelúcida (DMP é uma rara ectasia corneana cuja progressão resulta em astigmatismo irregular e baixa visual não corrigidos com óculos ou lentes de contato. O presente relato descreve um paciente com catarata e DMP que foi tratado com facoemulsificação e implante de lente intraocular tórica com recuperação da acuidade visual em ambos os olhos.Pellucid marginal degeneration (PMD is a rare corneal ectasia and its progression leads to irregular astigmatism and low vision that can not have spectacles or contact lens correction. This report describes a patient with low vision due to cataract and PMD that was treated with phacoemulsification and implantation of a toric intraocular lens with a satisfactory visual acuity outcome.

  8. Combinatorial construction of toric residues

    OpenAIRE

    Khetan, Amit; Soprounov, Ivan

    2004-01-01

    The toric residue is a map depending on n+1 semi-ample divisors on a complete toric variety of dimension n. It appears in a variety of contexts such as sparse polynomial systems, mirror symmetry, and GKZ hypergeometric functions. In this paper we investigate the problem of finding an explicit element whose toric residue is equal to one. Such an element is shown to exist if and only if the associated polytopes are essential. We reduce the problem to finding a collection of partitions of the la...

  9. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  10. Contact lens in keratoconus

    Science.gov (United States)

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL. PMID:23925325

  11. Contact lens in keratoconus

    OpenAIRE

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the En...

  12. Frobenius splitting of projective toric bundles

    Indian Academy of Sciences (India)

    He Xin

    2018-03-19

    Mar 19, 2018 ... Firstly it is easy to see that the image of s under the restriction map (2.5) falls in the χ-isotypical component of (Uσ , E), i.e. for all t ∈ T .... σ falls in the χ-isotypical component of (E,Uσ ). D. As mentioned in Remark 2.3, for a vector v .... The determinant of a toric bundle. LetE be a toric bundle on a toric variety X ...

  13. Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring

    Directory of Open Access Journals (Sweden)

    Anju Rastogi

    2018-01-01

    Full Text Available Purpose: To evaluate the rotational stability of toric intraocular lens (IOL when co-implanted with a capsular tension ring (CTR as compared to that of a toric IOL without a CTR. Methods: This was a prospective randomized clinical trial performed in a tertiary care centre in India. Fifty adult human eyes with visually significant cataract and regular corneal astigmatism ≥1.5D divided into two groups of 25 eyes each, A and B by simple randomization. Eyes with corneal pathology, lens subluxation, and a specular endothelial cell count <2000/mm2 were excluded from the study. The eyes in both the groups underwent standard phacoemulsification and were implanted with a toric IOL. In Group A, a CTR was put in the bag before IOL implantation. The groups were called for follow-up on day 1, 1 week, 1 month, and 3 months, postoperatively. The axis of the toric IOL on each visit was measured by slit lamp imaging in retroillumination and analyzed digitally. Results: Mean rotation of toric IOL at 3 months postoperatively was 1.85 ± 1.72° in Group A and 4.02 ± 2.04° in Group B. The difference was statistically significant (P = 0.003. Conclusion: Coimplantation of a CTR is a safe and effective technique for ensuring better rotational stability of toric IOLs.

  14. Toric Geometry of the Regular Convex Polyhedra

    Directory of Open Access Journals (Sweden)

    Fiammetta Battaglia

    2017-01-01

    Full Text Available We describe symplectic and complex toric spaces associated with the five regular convex polyhedra. The regular tetrahedron and the cube are rational and simple, the regular octahedron is not simple, the regular dodecahedron is not rational, and the regular icosahedron is neither simple nor rational. We remark that the last two cases cannot be treated via standard toric geometry.

  15. Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring.

    Science.gov (United States)

    Rastogi, Anju; Khanam, Samreen; Goel, Yashpal; Thacker, Prolima; Kumar, Prateek

    2018-03-01

    To evaluate the rotational stability of toric intraocular lens (IOL) when co-implanted with a capsular tension ring (CTR) as compared to that of a toric IOL without a CTR. This was a prospective randomized clinical trial performed in a tertiary care centre in India. Fifty adult human eyes with visually significant cataract and regular corneal astigmatism ≥1.5D divided into two groups of 25 eyes each, A and B by simple randomization. Eyes with corneal pathology, lens subluxation, and a specular endothelial cell count IOL. In Group A, a CTR was put in the bag before IOL implantation. The groups were called for follow-up on day 1, 1 week, 1 month, and 3 months, postoperatively. The axis of the toric IOL on each visit was measured by slit lamp imaging in retroillumination and analyzed digitally. Mean rotation of toric IOL at 3 months postoperatively was 1.85 ± 1.72° in Group A and 4.02 ± 2.04° in Group B. The difference was statistically significant (P = 0.003). Coimplantation of a CTR is a safe and effective technique for ensuring better rotational stability of toric IOLs.

  16. Frobenius splitting of projective toric bundles

    Indian Academy of Sciences (India)

    11

    Similarly, for each integer m ≥ 1 and n ≤ r, where r is the rank of E, the symmetric product SmE and wedge product ∧nE are also toric bundles. The associated Klyachko data of these toric bundles are the families of filtrations on the vector spaces SmE and ∧nE described as follows. (SmE)α(i) = { ∏. 1≤j≤m ej | ej ∈ E, 1 ...

  17. Mapping spaces and automorphism groups of toric noncommutative spaces

    Science.gov (United States)

    Barnes, Gwendolyn E.; Schenkel, Alexander; Szabo, Richard J.

    2017-09-01

    We develop a sheaf theory approach to toric noncommutative geometry which allows us to formalize the concept of mapping spaces between two toric noncommutative spaces. As an application, we study the `internalized' automorphism group of a toric noncommutative space and show that its Lie algebra has an elementary description in terms of braided derivations.

  18. Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators.

    Science.gov (United States)

    Park, Hyun Ju; Lee, Hun; Woo, Young Jae; Kim, Eung Kweon; Seo, Kyoung Yul; Kim, Ha Yan; Kim, Tae-im

    2015-07-01

    To compare the astigmatic power of toric intraocular lenses (IOLs) obtained from the AcrySof, TECNIS, and iTrace toric calculator in patients with preoperative with-the-rule (WTR) or against-the-rule (ATR) corneal astigmatism. Fifty eyes with cataract and corneal astigmatism greater than 0.75 diopters were enrolled in each group (WTR and ATR). Keratometric values were measured using autokeratometry, an IOLMaster, and an iTrace, which incorporated corneal topography and ray-tracing aberrometry. Based on measured keratometric values, the astigmatic power of each toric IOL was calculated using three toric calculators. Bland-Altman plots showed good agreement between six pairwise corneal astigmatism values in both groups. The TECNIS calculator tended to suggest a higher astigmatic power of the toric IOL than the AcrySof calculator. With the higher astigmatism and keratometric values from the IOLMaster, in both groups, calculations from the AcrySof and TECNIS calculators resulted in higher calculated astigmatic powers than those from same calculators with autokeratometry-measured values, demonstrating good agreement. With the higher calculated astigmatic power values, the values from the iTrace toric calculator using keratometric values obtained from iTrace ray tracing wavefront aberrometry or iTrace simulated keratometry showed fair to moderate agreement with those from the other calculator-keratometry pairs in both groups. To achieve the best refractive outcome after toric IOL implantation, understanding the differences in keratometric values between instruments and in calculated astigmatic power among toric calculator programs is necessary. Moreover, systemic analysis of each toric calculator in conjunction with postoperative data is required.

  19. c-Extremization from toric geometry

    Science.gov (United States)

    Amariti, Antonio; Cassia, Luca; Penati, Silvia

    2018-04-01

    We derive a geometric formulation of the 2d central charge cr from infinite families of 4d N = 1 superconformal field theories topologically twisted on constant curvature Riemann surfaces. They correspond to toric quiver gauge theories and are associated to D3 branes probing five dimensional Sasaki-Einstein geometries in the AdS/CFT correspondence. We show that cr can be expressed in terms of the areas of the toric diagram describing the moduli space of the 4d theory, both for toric geometries with smooth and singular horizons. We also study the relation between a-maximization in 4d and c-extremization in 2d, giving further evidences of the mixing of the baryonic symmetries with the exact R-current in two dimensions.

  20. [Toric add-on intraocular lenses for correction of high astigmatism after pseudophakic keratoplasty].

    Science.gov (United States)

    Hassenstein, A; Niemeck, F; Giannakakis, K; Klemm, M

    2017-06-01

    Perforating keratoplasty shows good morphological results with a clear cornea; however, a limiting factor is often the resulting astigmatism, which cannot be corrected with either glasses or contact lenses (CL) in up to 20% of the patients. We retrospectively investigated 15 patients after pseudophakic perforating keratoplasty, who received implantation of toric add-on intraocular lenses (IOL) to correct astigmatism. The mean preoperative astigmatism of 6.5 diopter (dpt) could be reduced to a mean postoperative value of 1.0 dpt. The mean visual acuity could be improved from a preoperative value of sc one case of a lens extension tear. Based on our good experiences we now provide toric add-on IOL to all patients with pseudophakic perforating keratoplasty when this cannot be corrected or only insufficiently corrected by conservative methods.

  1. Equivariant embeddings into smooth toric varieties

    OpenAIRE

    Hausen, Juergen

    2000-01-01

    We characterize embeddability of algebraic varieties into smooth toric varieties and prevarieties. Our embedding results hold also in an equivariant context and thus generalize a well known embedding theorem of Sumihiro on quasiprojective G-varieties. The main idea is to reduce the embedding problem to the affine case. This is done by constructing equivariant affine conoids, a tool which extends the concept of an equivariant affine cone over a projective G-variety to a more general framework.

  2. Dimensional analysis using toric ideals: primitive invariants.

    Directory of Open Access Journals (Sweden)

    Mark A Atherton

    Full Text Available Classical dimensional analysis in its original form starts by expressing the units for derived quantities, such as force, in terms of power products of basic units [Formula: see text] etc. This suggests the use of toric ideal theory from algebraic geometry. Within this the Graver basis provides a unique primitive basis in a well-defined sense, which typically has more terms than the standard Buckingham approach. Some textbook examples are revisited and the full set of primitive invariants found. First, a worked example based on convection is introduced to recall the Buckingham method, but using computer algebra to obtain an integer [Formula: see text] matrix from the initial integer [Formula: see text] matrix holding the exponents for the derived quantities. The [Formula: see text] matrix defines the dimensionless variables. But, rather than this integer linear algebra approach it is shown how, by staying with the power product representation, the full set of invariants (dimensionless groups is obtained directly from the toric ideal defined by [Formula: see text]. One candidate for the set of invariants is a simple basis of the toric ideal. This, although larger than the rank of [Formula: see text], is typically not unique. However, the alternative Graver basis is unique and defines a maximal set of invariants, which are primitive in a simple sense. In addition to the running example four examples are taken from: a windmill, convection, electrodynamics and the hydrogen atom. The method reveals some named invariants. A selection of computer algebra packages is used to show the considerable ease with which both a simple basis and a Graver basis can be found.

  3. Combined special capsular tension ring and toric IOL implantation for management of post-DALK high regular astigmatism with subluxated traumatic cataract.

    Science.gov (United States)

    Kandar, Asim Kumar

    2014-07-01

    We report a case of 18-year-old male who has undergone phacoemulsification with implantation of toric IOL (AcrySof IQ SN6AT9) after fixation of lens capsule with Cionni's capsular tension ring (CTR) for subluxated traumatic cataract with high astigmatism after deep anterior lamellar keratoplasty (DALK). He underwent right eye DALK for advanced keratoconus four years earlier. He had history of trauma one year later with displaced clear crystalline lens into  anterior chamber and graft dehiscence, which was repaired successfully. The graft survived, but patient developed cataract with subluxated lens, for which phacoemulsification with implantation of toric IOL was done. Serial  topography showed regular corneal astigmatism of -5.50 diopter (K 1 42.75 D @130°, K 2 48.25 D @40°). At 10-month follow-up, the patient has BCVA 20/30 with + 0.75 DS/- 1.75 DC @ 110°. The capsular bag is quite stable with well-centered IOL. Combination of Cionni's ring with toric IOL could be a good option to manage such complex cases.

  4. Combined special capsular tension ring and toric IOL implantation for management of post-DALK high regular astigmatism with subluxated traumatic cataract

    Directory of Open Access Journals (Sweden)

    Asim Kumar Kandar

    2014-01-01

    Full Text Available We report a case of 18-year-old male who has undergone phacoemulsification with implantation of toric IOL (AcrySof IQ SN6AT9 after fixation of lens capsule with Cionni′s capsular tension ring (CTR for subluxated traumatic cataract with high astigmatism after deep anterior lamellar keratoplasty (DALK. He underwent right eye DALK for advanced keratoconus four years earlier. He had history of trauma one year later with displaced clear crystalline lens into  anterior chamber and graft dehiscence, which was repaired successfully. The graft survived, but patient developed cataract with subluxated lens, for which phacoemulsification with implantation of toric IOL was done. Serial  topography showed regular corneal astigmatism of -5.50 diopter (K 1 42.75 D @130°, K 2 48.25 D @40°. At 10-month follow-up, the patient has BCVA 20/30 with + 0.75 DS/- 1.75 DC @ 110°. The capsular bag is quite stable with well-centered IOL. Combination of Cionni′s ring with toric IOL could be a good option to manage such complex cases.

  5. A toric varieties approach to geometrical structure of multi partite states

    International Nuclear Information System (INIS)

    Heydari, Hoshang

    2010-01-01

    We investigate the geometrical structures of multipartite states based on construction of toric varieties. In particular, we describe pure quantum systems in terms of affine toric varieties and projective embedding of these varieties in complex projective spaces. We show that a quantum system can be corresponds to a toric variety of a fan which is constructed by gluing together affine toric varieties of polytopes. Moreover, we show that the projective toric varieties are the spaces of separable multipartite quantum states. The construction is a generalization of the complex multi-projective Segre variety. Our construction suggests a systematic way of looking at the structures of multipartite quantum systems.

  6. Bilateral Implantation of Scleral-Fixated Cionni Endocapsular Rings and Toric Intraocular Lenses in a Pediatric Patient with Marfan’s Syndrome

    Directory of Open Access Journals (Sweden)

    Howard V. Gimbel

    2012-01-01

    Full Text Available The management of ectopia lentis in Marfan’s syndrome is challenging. Multiple disease-associated factors conspire to deprive these patients of adequate vision. While optical correction with glasses and contact lenses is usually advocated early on, the irregular astigmatism and even partial aphakia that accompanies advanced cases generally warrant surgical intervention. Several surgical strategies have been devised to manage these challenging cases, including the combination of endocapsular or pars plana lensectomy and iris or scleral fixation of the intraocular lens (IOL or IOL-bag complex. All of the reported cases have been implanted with IOLs that correct for myopia only. With toric lenses, it is now possible to correct for corneal astigmatism in these patients as well, provided that the capsular bag is maintained and can be properly centered. We report the combination of scleral-fixated Cionni endocapsular rings and toric IOLs in a pediatric patient with bilateral ectopia lentis secondary to Marfan’s syndrome.

  7. An optimal dissipative encoder for the toric code

    Science.gov (United States)

    Dengis, John; König, Robert; Pastawski, Fernando

    2014-01-01

    We consider the problem of preparing specific encoded resource states for the toric code by local, time-independent interactions with a memoryless environment. We propose the construction of such a dissipative encoder which converts product states to topologically ordered ones while preserving logical information. The corresponding Liouvillian is made up of four local Lindblad operators. For a qubit lattice of size L × L, we show that this process prepares encoded states in time O(L), which is optimal. This scaling compares favorably with known local unitary encoders for the toric code which take time of order Ω(L2) and require active time-dependent control.

  8. LIO pseudofácica suplementar sulcoflex® toric sobre LIO acrysof® toric

    Directory of Open Access Journals (Sweden)

    Hilton Arcoverde Gonçalves de Medeiros

    2013-10-01

    Full Text Available Para correção de alta hipermetropia e astigmatismo irregular secundário a múltiplas cirurgias refrativas em uma mulher de 45 anos, foi utilizada a sutura das incisões radiais, com implante de lente intraocular (LIO Acrysof® Toric. Para correção do residual de erro refracional, foi implantada LIO pseudofácica tórica suplementar sobre LIO Primária. A acuidade visual (AV inicial era de LogMAR 0,9 e a final de LogMAR 0,3. O implante da LIO suplementar tórica sobre LIO tórica primária mostrou-se uma boa opção, proporcionando melhora da acuidade visual.

  9. The quantum equivariant cohomology of toric manifolds through mirror symmetry

    OpenAIRE

    Baptista, J. M.

    2008-01-01

    Using mirror symmetry as described by Hori and Vafa, we compute the quantum equivariant cohomology ring of toric manifolds. This ring arises naturally in topological gauged sigma-models and is related to the Hamiltonian Gromov-Witten invariants of the target manifold.

  10. On the fundamental group of real toric varieties

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Finding K(π, 1) arrangements seems to be an interesting problem in topology (cf. [15] and [12]) and we get many such examples. Similar to the results of [12], ...... This is immediate because, V (τ ) is the toric variety associated to the fan Star(τ) which by definition (cf. p. 52 of [10]) is smooth and flag-like whenever is smooth ...

  11. An Optimal Dissipative Encoder for the Toric Code

    Science.gov (United States)

    2014-01-16

    corresponding Liouvillian is made up of four local Lindblad operators . For a qubit lattice of size L × L , we show that this process prepares encoded...this work may be used under the terms of the Creative Commons Attribution 3.0 licence . Any further distribution of this work must maintain attribution to...associated correction operations . For the toric code, an encoding procedure of this form was given [7]. It involves active error correction operations

  12. On the fundamental group of real toric varieties

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    our main object of study. For the definition and basic facts on real toric .... ((1 − t) · x + t · x{0})(u) = (1 − t) · x(u) + t · x{0}(u) > 0. This clearly holds since, x(u) > 0 and R. + is convex. .... D(X+,ϕ) is connected if and only if ̂ϕ is surjective which is equivalent to the assumption that the image of the primitive edge vectors span N ⊗Z ...

  13. Squashed Toric Sigma Models and Mock Modular Forms

    Science.gov (United States)

    Gupta, Rajesh Kumar; Murthy, Sameer

    2018-01-01

    We study a class of two-dimensional N}=(2,2)} sigma models called squashed toric sigma models, using their Gauged Linear Sigma Models (GLSM) description. These models are obtained by gauging the global {U(1)} symmetries of toric GLSMs and introducing a set of corresponding compensator superfields. The geometry of the resulting vacuum manifold is a deformation of the corresponding toric manifold in which the torus fibration maintains a constant size in the interior of the manifold, thus producing a neck-like region. We compute the elliptic genus of these models, using localization, in the case when the unsquashed vacuum manifolds obey the Calabi-Yau condition. The elliptic genera have a non-holomorphic dependence on the modular parameter {τ} coming from the continuum produced by the neck. In the simplest case corresponding to squashed {C / Z_{2 the elliptic genus is a mixed mock Jacobi form which coincides with the elliptic genus of the {N=(2,2)} {SL(2,R) / U(1)} cigar coset.

  14. Towards M2-brane theories for generic toric singularities

    International Nuclear Information System (INIS)

    Franco, Sebastian; RodrIguez-Gomez, Diego; Hanany, Amihay; Park, Jaemo

    2008-01-01

    We construct several examples of (2+1) dimensional N = 2 supersymmetric Chern-Simons theories, whose moduli space is given by non-compact toric Calabi-Yau four-folds, which are not derivable from any (3+1) dimensional CFT. One such example is the gauge theory associated with the cone over Q 111 . For several examples, we explicitly confirm the matter content, superpotential interactions and RG flows suggested by crystal models. Our results provide additional support to the idea that crystal models are relevant for describing the structure of these CFTs.

  15. Toric codes and quantum doubles from two-body Hamiltonians

    Energy Technology Data Exchange (ETDEWEB)

    Brell, Courtney G; Bartlett, Stephen D; Doherty, Andrew C [Centre for Engineered Quantum Systems, School of Physics, University of Sydney, Sydney (Australia); Flammia, Steven T, E-mail: cbrell@physics.usyd.edu.au [Perimeter Institute for Theoretical Physics, Waterloo (Canada)

    2011-05-15

    We present here a procedure to obtain the Hamiltonians of the toric code and Kitaev quantum double models as the low-energy limits of entirely two-body Hamiltonians. Our construction makes use of a new type of perturbation gadget based on error-detecting subsystem codes. The procedure is motivated by a projected entangled pair states (PEPS) description of the target models, and reproduces the target models' behavior using only couplings that are natural in terms of the original Hamiltonians. This allows our construction to capture the symmetries of the target models.

  16. The toric SO(10) F-theory landscape

    International Nuclear Information System (INIS)

    Buchmuller, W.; Dierigl, M.; Oehlmann, P.K.; Ruehle, F.

    2017-09-01

    Supergravity theories in more than four dimensions with grand unified gauge symmetries are an important intermediate step towards the ultraviolet completion of the Standard Model in string theory. Using toric geometry, we classify and analyze six-dimensional F-theory vacua with gauge group SO(10) taking into account Mordell-Weil U(1) and discrete gauge factors. We determine the full matter spectrum of these models, including charged and neutral SO(10) singlets. Based solely on the geometry, we compute all matter multiplicities and confirm the cancellation of gauge and gravitational anomalies independent of the base space. Particular emphasis is put on symmetry enhancements at the loci of matter fields and to the frequent appearance of superconformal points. They are linked to non-toric Kaehler deformations which contribute to the counting of degrees of freedom. We compute the anomaly coefficients for these theories as well by using a base-independent blow-up procedure and superconformal matter transitions. Finally, we identify six-dimensional supergravity models which can yield the Standard Model with high-scale supersymmetry by further compactification to four dimensions in an Abelian flux background.

  17. Q-factorial Gorenstein toric Fano varieties with large Picard number

    DEFF Research Database (Denmark)

    Nill, Benjamin; Øbro, Mikkel

    2010-01-01

    In dimension $d$, ${\\boldsymbol Q}$-factorial Gorenstein toric Fano varieties with Picard number $\\rho_X$ correspond to simplicial reflexive polytopes with $\\rho_X + d$ vertices. Casagrande showed that any $d$-dimensional simplicial reflexive polytope has at most $3 d$ and $3d-1$ vertices if $d...... having $3d-1$ vertices, corresponding to $d$-dimensional ${\\boldsymbol Q}$-factorial Gorenstein toric Fano varieties with Picard number $2d-1$. For $d$ even, there exist three such varieties, with two being singular, while for $d > 1$ odd there exist precisely two, both being nonsingular toric fiber...

  18. [Patients with astigmatism who underwent cataract surgery by phacoemulsification: toric IOL x asferic IOL?].

    Science.gov (United States)

    Torres Netto, Emilio de Almeida; Gulin, Marina Carvalho; Zapparoli, Marcio; Moreira, Hamilton

    2013-01-01

    Compare the visual acuity of patients who underwent cataract surgery by phacoemulsification with IOL AcrySof(®) toric implantation versus AcrySof(®) IQ and evaluate the reduction of cylindrical diopters (CD) in the postoperative period. Analytical and retrospective study of 149 eyes with 1 or more diopters of regular symmetrical keratometric astigmatism, which underwent cataract surgery by phacoemulsification. The eyes were divided into two groups: the toric group with 85 eyes and the non-toric group with 64 eyes. In the pre-operative phase, topographic data and refraction of each eye to be operated were assessed. In the postoperative phase, refraction and visual acuity with and without correction were measured. The preoperative topographic astigmatism ranged from 1.00 to 5.6 DC in both groups. Average reduction of 1.37 CD (p<0.001) and 0.16 CD (p=0.057) was obtained for the toric and non-toric group when compared to the refractive astigmatism, respectively. Considering visual acuity without correction (NCVA), the toric group presented 44 eyes (51.7%) with NCVA of 0 logMAR (20/20) or 0.1 logMAR (20/25) and the toric group presented 7 eyes (10.93%) with these same NCVA values. The results show that patients with a significant keratometric astigmatism presented visual benefits with the toric IOL implantation. The reduction of the use of optical aids may be obtained provided aberrations of the human eye are corrected more accurately. Currently, phacoemulsification surgery has been used not only for functional improvement, but also as a refraction procedure.

  19. Unique hard scleral lens post-LASIK ectasia fitting.

    Science.gov (United States)

    Mahadevan, Rajeswari; Jagadeesh, Divya; Rajan, Rajni; Arumugam, Amudha Oli

    2014-04-01

    This case report describes an experience with prosthetic replacement of ocular surface ecosystem (PROSE) device in an Indian patient with post-LASIK corneal ectasia. Keratoconus and corneal ectasia (post-LASIK) are characterized by progressive thinning and steepening of the cornea. Common symptoms experienced by patients in such conditions range from mild to severe vision impairments to an array of visual symptoms such as glare and ghosting. Scleral lenses are considered a vision-saving device when all other modalities fail. The patient in this case report had larger palpebral aperture, steeper cornea, and increased toricity of the sclera. Although a larger-diameter device is preferable in steeper corneas, a device with a smaller diameter and a flatter haptic was prescribed because of scleral toricity. There is a need to study scleral profile as well because scleral toricity can produce symptoms in patients even after 6 hours of device wear. After a few days of adaptation, the vault of the PROSE device can change because of haptic alignment on the sclera. This case report gives an overview of how the scleral profile can have an effect on the corneal/contact lens relationship when using a PROSE device.

  20. Secret Sharing Schemes with a large number of players from Toric Varieties

    DEFF Research Database (Denmark)

    Hansen, Johan P.

    A general theory for constructing linear secret sharing schemes over a finite field $\\Fq$ from toric varieties is introduced. The number of players can be as large as $(q-1)^r-1$ for $r\\geq 1$. We present general methods for obtaining the reconstruction and privacy thresholds as well as conditions...... for multiplication on the associated secret sharing schemes. In particular we apply the method on certain toric surfaces. The main results are ideal linear secret sharing schemes where the number of players can be as large as $(q-1)^2-1$. We determine bounds for the reconstruction and privacy thresholds...... and conditions for strong multiplication using the cohomology and the intersection theory on toric surfaces....

  1. 5d En Seiberg-Witten curve via toric-like diagram

    International Nuclear Information System (INIS)

    Kim, Sung-Soo; Yagi, Futoshi

    2015-01-01

    We consider 5d Sp(1) gauge theory with E N f +1 global symmetries based on toric(-like) diagram constructed from (p,q)-web with 7-branes. We propose a systematic procedure to compute the Seiberg-Witten curve for generic toric-like diagram. For N f =6,7 flavors, we explicitly compute the Seiberg-Witten curves for 5d Sp(1) gauge theory, and show that these Seiberg-Witten curves agree with already known E 7,8 results. We also discuss a generalization of the Seiberg-Witten curve to rank-N cases.

  2. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  3. F-Theory on all Toric Hypersurface Fibrations and its Higgs Branches

    CERN Document Server

    Klevers, Denis; Oehlmann, Paul-Konstantin; Piragua, Hernan; Reuter, Jonas

    2015-01-01

    We consider F-theory compactifications on genus-one fibered Calabi-Yau manifolds with their fibers realized as hypersurfaces in the toric varieties associated to the 16 reflexive 2D polyhedra. We present a base-independent analysis of the codimension one, two and three singularities of these fibrations. We use these geometric results to determine the gauge groups, matter representations, 6D matter multiplicities and 4D Yukawa couplings of the corresponding effective theories. All these theories have a non-trivial gauge group and matter content. We explore the network of Higgsings relating these theories. Such Higgsings geometrically correspond to extremal transitions induced by blow-ups in the 2D toric varieties. We recover the 6D effective theories of all 16 toric hypersurface fibrations by repeatedly Higgsing the theories that exhibit Mordell-Weil torsion. We find that the three Calabi-Yau manifolds without section, whose fibers are given by the toric hypersurfaces in P^2, P^1x P^1 and the recently studied ...

  4. Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Tendal, Britta

    2016-01-01

    TOPIC: We performed a systematic review and meta-analysis to evaluate the benefit and harms associated with implantation of toric intraocular lenses (IOLs) during cataract surgery. Outcomes were postoperative uncorrected distance visual acuity (UCDVA) and distance spectacle independence. Harms we...

  5. The Coherent-Constructible Correspondence and Homological Mirror Symmetry for Toric Varieties

    OpenAIRE

    Fang, Bohan; Liu, Chiu-Chu Melissa; Treumann, David; Zaslow, Eric

    2009-01-01

    This is an expository article describing recent results of the authors and David Nadler on microlocalization, the Fukaya category, and coherent sheaves on toric varieties. The original papers are arXiv:math/0604379, arXiv:math/0612399 and arXiv:0811.1228v1.

  6. Euler characteristics of moduli spaces of torsion free sheaves on toric surfaces

    NARCIS (Netherlands)

    Kool, M.

    2015-01-01

    Given a smooth toric variety X, the action of the torus T lifts to the moduli space M of stable sheaves on X. Using the pioneering work of Klyacho, a fairly explicit combinatorial description of the fixed point locus MT can be given (as shown by earlier work of the author). In this paper, we apply

  7. SECRET SHARING SCHEMES WITH STRONG MULTIPLICATION AND A LARGE NUMBER OF PLAYERS FROM TORIC VARIETIES

    DEFF Research Database (Denmark)

    Hansen, Johan Peder

    2017-01-01

    This article consider Massey's construction for constructing linear secret sharing schemes from toric varieties over a finite field $\\Fq$ with $q$ elements. The number of players can be as large as $(q-1)^r-1$ for $r\\geq 1$. The schemes have strong multiplication, such schemes can be utilized in ...

  8. Use of the Toric Surgical Marker to Aid in Intraoperative Plaque Placement for the USC Eye Physics Plaques to Treat Uveal Melanoma: A New Surgical Technique.

    Science.gov (United States)

    Berry, Jesse L; Kim, Jonathan W; Jennelle, Richard; Astrahan, Melvin

    2015-09-01

    To describe a new surgical technique for intraoperative placement of Eye Physics (EP) plaques for uveal melanoma using a toric marker. A toric marker is designed for cataract surgery to align the axis of astigmatism; its use was modified in this protocol to mark the axis of suture coordinates as calculated by Plaque Simulator (PS) software. The toric marker can be used to localize suture coordinates, in degrees, during intraoperative plaque placement. Linear marking using the toric marker decreases potential inaccuracies associated with the surgeon estimating 'clock-hours' by dot placement. Use of the toric marker aided surgical placement of EP plaques. The EP planning protocol is now designed to display the suture coordinates either by clock-hours or degrees, per surgeon preference. Future research is necessary to determine whether routine use of the toric marker improves operative efficiency. [Ophthalmic Surg Lasers Imaging Retina. 2015;46:866-870.]. Copyright 2015, SLACK Incorporated.

  9. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  10. D-branes at toric singularities: model building, Yukawa couplings and flavour physics

    International Nuclear Information System (INIS)

    Krippendorf, Sven; Dolan, Matthew J.; Maharana, Anshuman; Quevedo, Fernando

    2010-02-01

    We discuss general properties of D-brane model building at toric singularities. Using dimer techniques to obtain the gauge theory from the structure of the singularity, we extract results on the matter sector and superpotential of the corresponding gauge theory. We show that the number of families in toric phases is always less than or equal to three, with a unique exception being the zeroth Hirzebruch surface. With the physical input of three generations we find that the lightest family of quarks is massless and the masses of the other two can be hierarchically separated. We compute the CKM matrix for explicit models in this setting and find the singularities possess sufficient structure to allow for realistic mixing between generations and CP violation. (author)

  11. Quantum cohomology and closed-string mirror symmetry for toric varieties

    OpenAIRE

    Smith, Jack

    2018-01-01

    We give a short new computation of the quantum cohomology of an arbitrary smooth toric variety X, by showing directly that it is isomorphic to a Jacobian-like ring, assuming the existence and properties of certain counts of pseudoholomorphic discs with boundary on a Lagrangian torus fibre. The proof is purely algebraic and uses a degeneration of the target ring which turns the Novikov parameter down to zero, where an explicit inverse can be written. The hypotheses have been verified by Fukaya...

  12. Toric Geometry, Sasaki-Einstein Manifolds and a New Infinite Class of AdS/CFT Duals

    CERN Document Server

    Martelli, D; Martelli, Dario; Sparks, James

    2006-01-01

    Recently an infinite family of explicit Sasaki-Einstein metrics Y^{p,q} on S^2 x S^3 has been discovered, where p and q are two coprime positive integers, with qtoric. Aided by several recent results in toric geometry, we show that these are Kahler quotients C^4//U(1), namely the vacua of gauged linear sigma models with charges (p,p,-p+q,-p-q), thereby generalising the conifold, which is p=1,q=0. We present the corresponding toric diagrams and show that these may be embedded in the toric diagram for the orbifold C^3/Z_{p+1}xZ_{p+1} for all q

    toric quiver gauge theories with gauge group SU(N)^{2p}. As a non-trivial example, we show that Y^{2,1} is an explicit irregular Sasaki-Einstein metric on the horizon of the complex cone over the first del Pezz...

  13. Line bundle twisted chiral de Rham complex and bound states of D-branes on toric manifolds

    International Nuclear Information System (INIS)

    Parkhomenko, S.E.

    2014-01-01

    In this note we calculate elliptic genus in various examples of twisted chiral de Rham complex on two-dimensional toric compact manifolds and Calabi–Yau hypersurfaces in toric manifolds. At first the elliptic genus is calculated for the line bundle twisted chiral de Rham complex on a compact smooth toric manifold and K3 hypersurface in P 3 . Then we twist chiral de Rham complex by sheaves localized on positive codimension submanifolds in P 2 and calculate in each case the elliptic genus. In the last example the elliptic genus of chiral de Rham complex on P 2 twisted by SL(N) vector bundle with instanton number k is calculated. In all the cases considered we find the infinite tower of open string oscillator contributions and identify directly the open string boundary conditions of the corresponding bound state of D-branes

  14. A theoretical lens on a biology intensive orientation program: A study of self-efficacy and self-regulation of freshman biology majors

    Science.gov (United States)

    Wheeler, Erin R.

    There is a national effort to increase the number of undergraduate students graduating in science, math, engineering, and technology (STEM) (National Science Foundation, 2007). The majority of students initially populating these STEM majors ultimately switch to and graduate from non-STEM majors (Seymour & Hewitt, 2000; Seymour, 2002). The source of attrition from STEM fields lies within the difficulty of concepts presented in freshman STEM introductory courses (Jensen & Moore, 2007, 2008, 2009; Seymour & Hewitt, 2000). These gateway courses are considered high-risk because nearly half of students enrolled in these courses receive either a "D" or "F" or completely withdraw from the course (Labov, 2004). Research shows that students who have uncalibrated self-efficacy and an attenuated self-regulated learning are unsuccessful in high-risk courses (Kitsantas et al., 2008; Ross, Green, Salisbury-Glennon, & Tollefson, 2006; Zimmerman, 2002). Traditional academic assistance, such as tutoring, learning to learn courses, and supplemental instruction, does not explicitly develop an undergraduate's self-efficacy and self-regulated learning as it specifically relates to the STEM domains (Cao & Nietfeld, 2007; Dembo & Seli, 2006; Ross et al., 2006; Simpson, Hind, Nist, Burrell, 1997). Some STEM departments have created academic interventions, such as one-credit seminars, orientation programs, and bridge programs, to directly address the needs of STEM majors (Belzer, 2003; Bonner, 2009; Chevalier, Chrisman, & Kelsey, 2001; Hutchison-Green, Follman, & Bodner, 2008; D. J. Minchella, Yazvac, C. W., Fodrea, R. A., Ball G., 2007; Reyes, Anderson-Rowland, & McCartney, 1998). This study focused on the effect of a biology-intensive orientation program on biology majors' self-efficacy and self-regulated learning. The study utilized approximately 300 undergraduate biology majors participating in a biology-intensive orientation that occurred on August 7-12, 2011, at a public state

  15. Brane brick models, toric Calabi-Yau 4-folds and 2d (0,2) quivers

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Sebastián [Physics Department, The City College of the CUNY, 160 Convent Avenue, New York, NY 10031 (United States); The Graduate School and University Center, The City University of New York,365 Fifth Avenue, New York NY 10016 (United States); Lee, Sangmin [Center for Theoretical Physics, Seoul National University,Seoul 08826 (Korea, Republic of); Department of Physics and Astronomy, Seoul National University,Seoul 08826 (Korea, Republic of); College of Liberal Studies, Seoul National University,Seoul 08826 (Korea, Republic of); School of Natural Sciences, Institute for Advanced Study,Princeton, NJ 08540 (United States); Seong, Rak-Kyeong [School of Physics, Korea Institute for Advanced Study,Seoul 02455 (Korea, Republic of)

    2016-02-08

    We introduce brane brick models, a novel type of Type IIA brane configurations consisting of D4-branes ending on an NS5-brane. Brane brick models are T-dual to D1-branes over singular toric Calabi-Yau 4-folds. They fully encode the infinite class of 2d (generically) N=(0,2) gauge theories on the worldvolume of the D1-branes and streamline their connection to the probed geometries. For this purpose, we also introduce new combinatorial procedures for deriving the Calabi-Yau associated to a given gauge theory and vice versa.

  16. Computing the Chern–Schwartz–MacPherson class of complete simplical toric varieties

    DEFF Research Database (Denmark)

    Helmer, Martin

    2017-01-01

    Topological invariants such as characteristic classes are an important tool to aid in understanding and categorizing the structure and properties of algebraic varieties. In this note, we consider the problem of computing a particular characteristic class, the Chern–Schwartz–MacPherson class......, of a complete simplicial toric variety X∑ defined by a fan ∑ from the combinatorial data contained in the fan ∑. Specifically, we give an effective combinatorial algorithm to compute the Chern–Schwartz–MacPherson class of X∑, in the Chow ring (or rational Chow ring) of X∑. This method is formulated by combining...

  17. Discrete Symmetries of Calabi-Yau Hypersurfaces in Toric Four-Folds

    Science.gov (United States)

    Braun, Andreas P.; Lukas, Andre; Sun, Chuang

    2017-12-01

    We analyze freely-acting discrete symmetries of Calabi-Yau three-folds defined as hypersurfaces in ambient toric four-folds. An algorithm that allows the systematic classification of such symmetries which are linearly realised on the toric ambient space is devised. This algorithm is applied to all Calabi-Yau manifolds with {h^{1,1}(X)≤ 3} obtained by triangulation from the Kreuzer-Skarke list, a list of some 350 manifolds. All previously known freely-acting symmetries on these manifolds are correctly reproduced and we find five manifolds with freely-acting symmetries. These include a single new example, a manifold with a {Z_2×Z_2} symmetry where only one of the {Z_2} factors was previously known. In addition, a new freely-acting {Z_2} symmetry is constructed for a manifold with {h^{1,1}(X)=6} . While our results show that there are more freely-acting symmetries within the Kreuzer-Skarke set than previously known, it appears that such symmetries are relatively rare.

  18. Entanglement negativity and sudden death in the toric code at finite temperature

    Science.gov (United States)

    Hart, O.; Castelnovo, C.

    2018-04-01

    We study the fate of quantum correlations at finite temperature in the two-dimensional toric code using the logarithmic entanglement negativity. We are able to obtain exact results that give us insight into how thermal excitations affect quantum entanglement. The toric code has two types of elementary excitations (defects) costing different energies. We show that an O (1 ) density of the lower energy defect is required to degrade the zero-temperature entanglement between two subsystems in contact with one another. However, one type of excitation alone is not sufficient to kill all quantum correlations, and an O (1 ) density of the higher energy defect is required to cause the so-called sudden death of the negativity. Interestingly, if the energy cost of one of the excitations is taken to infinity, quantum correlations survive up to arbitrarily high temperatures, a feature that is likely shared with other quantum spin liquids and frustrated systems in general, when projected down to their low-energy states. We demonstrate this behavior both for small subsystems, where we can prove that the negativity is a necessary and sufficient condition for separability, as well as for extended subsystems, where it is only a necessary condition. We further observe that the negativity per boundary degree of freedom at a given temperature increases (parametrically) with the size of the boundary, and that quantum correlations between subsystems with extended boundaries are more robust to thermal fluctuations.

  19. Comparison of clinical outcomes between limbal relaxing incisions and toric intraocular lenses in eyes with astigmatic corneas

    Directory of Open Access Journals (Sweden)

    Giuliano de Oliveira Freitas

    2014-01-01

    Full Text Available Objective: To compare refractive and vectorial outcomes of limbal relaxing incisions (LRI versus toric intraocular lenses (IOL in the treatment of preexisting corneal astigmatism at the time of phacoemulsification. Methods: This longitudinal observational case series assessed 62 eyes of 31 consecutive cataract patients with preoperative corneal astigmatism between 0.75 and 2.50 diopters in both eyes. Patients were randomly assorted in two groups: one assigned to receive AcrySof Toric™ IOL in both eyes, and another one assigned to have AcrySof Natural™ IOL associated with LRI, also in both eyes. All patients were re-evaluated, postoperatively, at 1, 3 and 6 months, when refractive astigmatism analysis was performed using vectorial methods proposed by Thibos. Variability of outcomes within each group and between groups were assessed and compared. Results: Manifest refractive cylinder, in diopters (D, as means ± standard deviation, in the LRI group for 1-month, 3-month and 6-month re-evalutions were respectively -0.66 ± 0.30; -0.70 ± 0.21 and -0.74 ± 0.26 when compared to -0.58 ± 0.24; -0.63 ± 0.20, and -0.62 ± 0.17 in the toric IOL group. (p value ≥ 0.06. Vectorial analysis evidenced greater astigmatism reduction in the toric IOL group in the 6th postoperative month, when postoperative mean astigmatic power vector was 0.31 D, when compared to 0.37 D in the LRI group (p value = 0.00. Conclusions: A trend of slightly better refractive outcomes favoring toric IOL group was seen, although such a trend was not statistically significant. Vectorial analysis, however, suggests that the use of toric IOL may constitute a more advantageous approach in the treatment of pre-existing corneal astigmatism, simultaneously with phacoemulsification.

  20. Toric Sasaki-Einstein metrics on S2xS3

    International Nuclear Information System (INIS)

    Martelli, Dario; Sparks, James

    2005-01-01

    We show that by taking a certain scaling limit of a Euclideanised form of the Plebanski-Demianski metrics one obtains a family of local toric Kahler-Einstein metrics. These can be used to construct local Sasaki-Einstein metrics in five dimensions which are generalisations of the Y p,q manifolds. In fact, we find that these metrics are diffeomorphic to those recently found by Cvetic, Lu, Page and Pope. We argue that the corresponding family of smooth Sasaki-Einstein manifolds all have topology S 2 xS 3 . We conclude by setting up the equations describing the warped version of the Calabi-Yau cones, supporting (2,1) three-form flux

  1. Exact results for N=2 supersymmetric gauge theories on compact toric manifolds and equivariant Donaldson invariants

    Energy Technology Data Exchange (ETDEWEB)

    Bershtein, Mikhail [Landau Institute for Theoretical Physics,Chernogolovka (Russian Federation); National Research University Higher School of Economics,International Laboratory of Representation Theory and Mathematical Physics,Institute for Information Transmission Problems,Moscow (Russian Federation); Independent University of Moscow,Moscow (Russian Federation); Bonelli, Giulio; Ronzani, Massimiliano; Tanzini, Alessandro [International School of Advanced Studies (SISSA), and INFN, Sezione di Trieste, via Bonomea 265, 34136 Trieste (Italy)

    2016-07-05

    We provide a contour integral formula for the exact partition function of N=2 supersymmetric U(N) gauge theories on compact toric four-manifolds by means of supersymmetric localisation. We perform the explicit evaluation of the contour integral for U(2) N=2{sup ∗} theory on ℙ{sup 2} for all instanton numbers. In the zero mass case, corresponding to the N=4 supersymmetric gauge theory, we obtain the generating function of the Euler characteristics of instanton moduli spaces in terms of mock-modular forms. In the decoupling limit of infinite mass we find that the generating function of local and surface observables computes equivariant Donaldson invariants, thus proving in this case a long-standing conjecture by N. Nekrasov. In the case of vanishing first Chern class the resulting equivariant Donaldson polynomials are new.

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lens because they can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, ... Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes ...

  3. REFRACTIVE NEUTRON LENS

    OpenAIRE

    Petrov, P. V.; Kolchevsky, N. N.

    2013-01-01

    Compound concave refractive lenses are used for focusing neutron beam. Investigations of spectral and focusing properties of a refractive neutron lens are presented. Resolution of the imaging system on the base of refractive neutron lenses depends on material properties and parameters of neutron source. Model of refractive neutron lens are proposed. Results of calculation diffraction resolution and focal depth of refractive neutron lens are discussed.

  4. Exact quantization conditions, toric Calabi-Yau and non-perturbative topological string

    International Nuclear Information System (INIS)

    Sun, Kaiwen; Wang, Xin; Huang, Min-xin

    2017-01-01

    We establish the precise relation between the Nekrasov-Shatashvili (NS) quantization scheme and Grassi-Hatsuda-Mariño conjecture for the mirror curve of arbitrary toric Calabi-Yau threefold. For a mirror curve of genus g, the NS quantization scheme leads to g quantization conditions for the corresponding integrable system. The exact NS quantization conditions enjoy a self S-duality with respect to Planck constant ℏ and can be derived from the Lockhart-Vafa partition function of non-perturbative topological string. Based on a recent observation on the correspondence between spectral theory and topological string, another quantization scheme was proposed by Grassi-Hatsuda-Mariño, in which there is a single quantization condition and the spectra are encoded in the vanishing of a quantum Riemann theta function. We demonstrate that there actually exist at least g nonequivalent quantum Riemann theta functions and the intersections of their theta divisors coincide with the spectra determined by the exact NS quantization conditions. This highly nontrivial coincidence between the two quantization schemes requires infinite constraints among the refined Gopakumar-Vafa invariants. The equivalence for mirror curves of genus one has been verified for some local del Pezzo surfaces. In this paper, we generalize the correspondence to higher genus, and analyze in detail the resolved ℂ"3/ℤ_5 orbifold and several SU(N) geometries. We also give a proof for some models at ℏ=2π/k.

  5. Exact quantization conditions, toric Calabi-Yau and non-perturbative topological string

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kaiwen [Department of Mathematics, University of Science and Technology of China,96 Jinzhai Road, Hefei, Anhui 230026 (China); Wang, Xin; Huang, Min-xin [Interdisciplinary Center for Theoretical Study,Department of Modern Physics, University of Science and Technology of China,96 Jinzhai Road, Hefei, Anhui 230026 (China)

    2017-01-16

    We establish the precise relation between the Nekrasov-Shatashvili (NS) quantization scheme and Grassi-Hatsuda-Mariño conjecture for the mirror curve of arbitrary toric Calabi-Yau threefold. For a mirror curve of genus g, the NS quantization scheme leads to g quantization conditions for the corresponding integrable system. The exact NS quantization conditions enjoy a self S-duality with respect to Planck constant ℏ and can be derived from the Lockhart-Vafa partition function of non-perturbative topological string. Based on a recent observation on the correspondence between spectral theory and topological string, another quantization scheme was proposed by Grassi-Hatsuda-Mariño, in which there is a single quantization condition and the spectra are encoded in the vanishing of a quantum Riemann theta function. We demonstrate that there actually exist at least g nonequivalent quantum Riemann theta functions and the intersections of their theta divisors coincide with the spectra determined by the exact NS quantization conditions. This highly nontrivial coincidence between the two quantization schemes requires infinite constraints among the refined Gopakumar-Vafa invariants. The equivalence for mirror curves of genus one has been verified for some local del Pezzo surfaces. In this paper, we generalize the correspondence to higher genus, and analyze in detail the resolved ℂ{sup 3}/ℤ{sub 5} orbifold and several SU(N) geometries. We also give a proof for some models at ℏ=2π/k.

  6. Toric K3-fibred Calabi-Yau manifolds with del Pezzo divisors for string compactifications

    Energy Technology Data Exchange (ETDEWEB)

    Cicoli, Michele [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Mayrhofer, Christoph [Heidelberg Univ. (Germany). Inst. fuer Theoretische Physik; Kreuzer, Maximilian

    2011-06-15

    We analyse several explicit toric examples of compact K3-fibred Calabi-Yau three-folds which can be used for the study of string dualities and are crucial ingredients for the construction of LARGE Volume type IIB vacua with promising applications to cosmology and particle phenomenology. In order to build a phenomenologically viable model, on top of the two moduli corresponding to the base and the K3 fibre, we demand also the existence of two additional rigid divisors: the first supporting the non-perturbative effects needed to achieve moduli stabilisation, and the second allowing the presence of chiral matter on wrapped D-branes. We clarify the topology of these rigid divisors by discussing the interplay between a diagonal structure of the Calabi-Yau volume and D-terms. Del Pezzo divisors appearing in the volume form in a completely diagonal way are natural candidates for supporting non-perturbative effects and for quiver constructions, while 'non-diagonal' del Pezzo and rigid but not del Pezzo divisors are particularly interesting for model building in the geometric regime. Searching through the existing list of four dimensional reflexive lattice polytopes, we find 158 examples admitting a Calabi-Yau hypersurface which is a K3 fibration with four Kaehler moduli where at least one of them is a 'diagonal' del Pezzo. We work out explicitly the topological details of a few examples showing how, in the case of simplicial polytopes, all the del Pezzo divisors are 'diagonal', while 'non-diagonal' ones appear only in the case of non-simplicial polytopes. A companion paper will use these results in the study of moduli stabilisation for globally consistent explicit Calabi-Yau compactifications with the local presence of chirality. (orig.)

  7. Toric K3-fibred Calabi-Yau manifolds with del Pezzo divisors for string compactifications

    International Nuclear Information System (INIS)

    Cicoli, Michele; Mayrhofer, Christoph; Kreuzer, Maximilian

    2011-06-01

    We analyse several explicit toric examples of compact K3-fibred Calabi-Yau three-folds which can be used for the study of string dualities and are crucial ingredients for the construction of LARGE Volume type IIB vacua with promising applications to cosmology and particle phenomenology. In order to build a phenomenologically viable model, on top of the two moduli corresponding to the base and the K3 fibre, we demand also the existence of two additional rigid divisors: the first supporting the non-perturbative effects needed to achieve moduli stabilisation, and the second allowing the presence of chiral matter on wrapped D-branes. We clarify the topology of these rigid divisors by discussing the interplay between a diagonal structure of the Calabi-Yau volume and D-terms. Del Pezzo divisors appearing in the volume form in a completely diagonal way are natural candidates for supporting non-perturbative effects and for quiver constructions, while 'non-diagonal' del Pezzo and rigid but not del Pezzo divisors are particularly interesting for model building in the geometric regime. Searching through the existing list of four dimensional reflexive lattice polytopes, we find 158 examples admitting a Calabi-Yau hypersurface which is a K3 fibration with four Kaehler moduli where at least one of them is a 'diagonal' del Pezzo. We work out explicitly the topological details of a few examples showing how, in the case of simplicial polytopes, all the del Pezzo divisors are 'diagonal', while 'non-diagonal' ones appear only in the case of non-simplicial polytopes. A companion paper will use these results in the study of moduli stabilisation for globally consistent explicit Calabi-Yau compactifications with the local presence of chirality. (orig.)

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non-Prescription Contact Lens Laura: Vision ... Robyn: Blurry Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... in a pair of colored contact lenses, Laura Butler of Parkersburg, W.Va., had "extreme pain in ... to wear any kind of contact lens. In Butler's case, the lenses caused an infection and left ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an impulsive buy from a souvenir shop, but 10 hours after she first put in a pair ... Prescription Contact Lens Laura: Vision Loss After Just 10 Hours Robyn: Blurry Vision and Daily Eye Drops ...

  18. bubble chamber lens

    CERN Multimedia

    Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over- ... without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... an ophthalmologist — an eye medical doctor — who will measure each eye and talk to you about proper ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  3. Viscous froth lens

    Science.gov (United States)

    Green, T. E.; Bramley, A.; Lue, L.; Grassia, P.

    2006-11-01

    Microscale models of foam structure traditionally incorporate a balance between bubble pressures and surface tension forces associated with curvature of bubble films. In particular, models for flowing foam microrheology have assumed this balance is maintained under the action of some externally imposed motion. Recently, however, a dynamic model for foam structure has been proposed, the viscous froth model, which balances the net effect of bubble pressures and surface tension to viscous dissipation forces: this permits the description of fast-flowing foam. This contribution examines the behavior of the viscous froth model when applied to a paradigm problem with a particularly simple geometry: namely, a two-dimensional bubble “lens.” The lens consists of a channel partly filled by a bubble (known as the “lens bubble”) which contacts one channel wall. An additional film (known as the “spanning film”) connects to this bubble spanning the distance from the opposite channel wall. This simple structure can be set in motion and deformed out of equilibrium by applying a pressure across the spanning film: a rich dynamical behavior results. Solutions for the lens structure steadily propagating along the channel can be computed by the viscous froth model. Perturbation solutions are obtained in the limit of a lens structure with weak applied pressures, while numerical solutions are available for higher pressures. These steadily propagating solutions suggest that small lenses move faster than large ones, while both small and large lens bubbles are quite resistant to deformation, at least for weak applied back pressures. As the applied back pressure grows, the structure with the small lens bubble remains relatively stiff, while that with the large lens bubble becomes much more compliant. However, with even further increases in the applied back pressure, a critical pressure appears to exist for which the steady-state structure loses stability and unsteady

  4. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  5. Accuracy of intraocular lens power calculation using three optical biometry measurement devices: the OA-2000, Lenstar-LS900 and IOLMaster-500.

    Science.gov (United States)

    Reitblat, Olga; Levy, Adi; Kleinmann, Guy; Assia, Ehud I

    2018-03-12

    To compare ocular measurements of three optical biometry devices and their application in intraocular lens (IOL) power calculations. One hundred and forty eyes which had undergone cataract extraction surgery with preoperative biometry with OA--2000, IOLMaster-500, and Lenstar-LS900 were enrolled. Biometry measurements of the three devices were compared. The deviation of the postoperative refraction from the preoperative refractive target was calculated with different formulas (Barrett Universal II, Hoffer Q, Holladay I, and SRK/T). Errors in the predicted astigmatism using the Barrett toric calculator were calculated for the toric IOLs. Additional 6465 eyes in which the IOLMaster-500 failed to measure axial length (AL) were reviewed. The percentage of successful measurements using the OA-2000 in those eyes was calculated. High agreement was found between the three devices for AL, anterior chamber depth, and average keratometry measurements (interclass correlation confidents: 1.000, 0.970, and 0.998, respectively, P 2000 yielded a lower against-the-rule (ATR) centroid error in the predicted astigmatism than the IOLMaster-500 and Lenstar-LS900 (0.06 D ± 0.59 at 13.4° vs. 0.20 D ± 0.61 at 14.8° and 0.16 D ± 0.55 at 21.4°, respectively, P 2000 had 284 (94.35%) successful measurements. The OA-2000 measurements showed good agreement with those of the IOLMaster-500 and Lenstar-LS900. Our results may suggest a potential advantage of the OA-2000 device in toric IOLs calculations and AL measurement success rate.

  6. Prospective study of toric IOL outcomes based on the Lenstar LS 900® dual zone automated keratometer.

    Science.gov (United States)

    Gundersen, Kjell Gunnar; Potvin, Richard

    2012-07-16

    To establish clinical expectations when using the Lenstar LS 900® dual-zone automated keratometer for surgery planning of toric intraocular lenses. Fifty eyes were measured with the Lenstar LS 900® dual-zone automated keratometer . Surgical planning was performed with the data from this device and the known surgically induced astigmatism of the surgeon. Post-operative refractions and visual acuity were measured at 1 month and 3 months. Clinical outcomes from 43 uncomplicated surgeries showed an average post-operative refractive astigmatism of 0.44D ±0.25D. Over 70% of eyes had 0.50D or less of refractive astigmatism and no eye had more than 1.0D of refractive astigmatism. Uncorrected visual acuity was 20/32 or better in all eyes at 3 months, with 70% of eyes 20/20 or better. A significantly higher number of eyes had 0.75D or more of post-operative refractive astigmatism when the standard deviation of the pre-operative calculated corneal astigmatism angle, reported by the keratometer, was > 5 degrees. In this single-site study investigating the use of the keratometry from the Lenstar LS 900® for toric IOL surgical planning, clinical outcomes appear equivalent to those reported in the literature for manual keratometry and somewhat better than has been reported for some previous automated instruments. A high standard deviation in the pre-operative calculated astigmatism angle, as reported by the keratometer, appears to increase the likelihood of higher post-operative refractive astigmatism.

  7. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ...

  10. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  11. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  13. bubble chamber lens

    CERN Multimedia

    Was used in a PS experiment. Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  14. Thermal Lens Microscope

    Science.gov (United States)

    Uchiyama, Kenji; Hibara, Akihide; Kimura, Hiroko; Sawada, Tsuguo; Kitamori, Takehiko

    2000-09-01

    We developed a novel laser microscope based on the thermal lens effect induced by a coaxial beam comprised of excitation and probe beams. The signal generation mechanism was confirmed to be an authentic thermal lens effect from the measurement of signal and phase dependences on optical configurations between the sample and the probe beam focus, and therefore, the thermal lens effect theory could be applied. Two-point spatial resolution was determined by the spot size of the excitation beam, not by the thermal diffusion length. Sensitivity was quite high, and the detection ability, evaluated using a submicron microparticle containing dye molecules, was 0.8 zmol/μm2, hence a distribution image of trace chemical species could be obtained quantitatively. In addition, analytes are not restricted to fluorescent species, therefore, the thermal lens microscope is a promising analytical microscope. A two-dimensional image of a histamine molecule distribution, which was produced in mast cells at the femtomole level in a human nasal mucous polyp, was obtained.

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact ... After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter ...

  16. The eye lens crystallins : a playground for evolution

    NARCIS (Netherlands)

    Werten, P.J.L.

    2000-01-01

    From the dawn of evolution where primitive one-cellular organisms oriented themselves to the light of our sun by simple photoreceptors in search of energy to sustain their existence, to the current day where light from the environment is captured by our eyes, focused on the retina by the eye lens

  17. Clinical survey of lens care in contact lens patients.

    Science.gov (United States)

    Ky, W; Scherick, K; Stenson, S

    1998-10-01

    Overall, contact lenses provide a safe and effective modality for vision correction. However, problems do occasionally arise. Up to 80% of contact lens complications can be traced to poor patient compliance with recommended lens care guidelines. We conducted a survey to evaluate the level of patient compliance in specific areas of lens care and maintenance and to assess patient knowledge of basic contact lens information. Patients were asked to complete an anonymous 15 question survey that focused on lens care--specifically the use of contact lens cleaners, methods of disinfection, enzyme treatments, use of rewetting drops, and the frequency of follow-up exams. In addition, the survey included six true/false questions relating to contact lens care and safety. There were a total of 103 participants in the study. Approximately 24% of patients stated they never cleaned their lenses prior to disinfection, and 5% used saline solutions as their primary mode of disinfection. A sizable portion of those surveyed (43% of soft lens wearers and 71% of rigid gas permeable lens wearers) either never used enzyme cleaners or used them less than once a month. Seventy percent of patients either never used rewetting drops or used them less than once a day. Twenty-nine percent of patients consulted their eye care professionals every 2 years and 6% less often than every two years. Six questions assessed patient knowledge of contact lens care safety. Of a possible six out of six correct answers, the mean number of correct responses was 3.74. A sizable proportion of contact lens wearers do not adequately adhere to recommended contact lens care, and many have an inadequate understanding of contact lens care guidelines. Therefore, it is important that practitioners place more emphasis on patient education at the time of initial contact lens fitting and reinforce such instruction during follow-up visits.

  18. [Correct contact lens hygiene].

    Science.gov (United States)

    Blümle, S; Kaercher, T; Khaireddin, R

    2013-06-01

    Although contact lenses have long been established in ophthalmology, practical aspects of handling contact lenses is becoming increasingly less important in the clinical training as specialist for ophthalmology. Simultaneously, for many reasons injuries due to wearing contact lenses are increasing. In order to correct this discrepancy, information on contact lenses and practical experience with them must be substantially increased from a medical perspective. This review article deals with the most important aspects for prevention of complications, i.e. contact lens hygiene.

  19. Compound refractive X-ray lens

    International Nuclear Information System (INIS)

    Nygren, D.R.; Cahn, R.; Cederstrom, B.; Danielsson, M.; Vestlund, J.

    2000-01-01

    An apparatus and method are disclosed for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point

  20. Prolonging contact lens wear and making contact lens wear safer.

    Science.gov (United States)

    Foulks, Gary N

    2006-02-01

    To summarize the present status of safety and efficacy of contact lens wear. Literature review. Ovid Medline searches were performed on records from 1966 through 2005 using keywords: keratitis, contact lens complications, extended-wear contact lenses, and silicone-hydrogel contact lenses. Patients desire comfort, clarity of vision, and prolonged contact lens wear when contact lenses are used to correct refractive error. Practitioners desire patient satisfaction but also require maintenance of the integrity of the eye and no complications that jeopardize vision or health of the eye. Improvements in the oxygen permeability of the contact lens materials, design of the contact lens and its surface, and solutions for the maintenance of the lens have reduced but not eliminated the risks of infection, inflammation, and conjunctival papillary reaction associated with contact lens wear. The lessons of past and recent history suggest that patient education and practitioner participation in the management of contact lens wear continue to be critical factors for patient satisfaction and safety in the extended wear of contact lenses. The availability of highly oxygen permeable contact lenses has increased the tolerance and safety of extended contact lens wear, but patient instruction and education in proper use and care of lenses is required and caution is advised.

  1. Corneo-scleral contact lens in a piggyback system for keratoconus: A case report.

    Science.gov (United States)

    Porcar, Esteban; Montalt, Juan Carlos; España-Gregori, Enrique; Peris-Martínez, Cristina

    2017-06-01

    We describe a case of fitting a corneo-scleral contact lens with a multi-aspheric geometry design (MAGD CScL) on top of a daily silicone hydrogel lens (piggyback system) for keratoconus management. A 48-year-old man using soft toric contact lenses required an improvement in the unsatisfactory quality of his vision. He presented with bilateral asymmetric keratoconus with high myopia in the right eye (RE) and severe myopia in the left eye (LE). In addition, he had low vision in his LE because of a maculopathy. He was fitted with MAGD CScL to correct his irregular astigmatism. A diagnostic trial set was used in the fitting process and the patient was assessed according to a standardised fitting methodology. Visual acuity, corneal topography and contrast sensitivity were evaluated. The follow-up period was 1year. The best spectacle-corrected visual acuity was 0.5 logMAR for the RE with -10 D/-5 D×60° and 2 logMAR for the LE with -20 D/-3 D×105°. After fitting MAGD CScL, visual acuity improved significantly to 0.1 logMAR for the RE and 1.3 logMAR for the LE, as well as contrast sensitivity. The fitting parameters of the base curve, diameter, and power were 7.05mm, 12.60mm, -18.50 D and 7.15mm, 12.60mm, -19 D for the RE and LE, respectively. Optimal fitting characteristics were found in terms of lens position and lens movement. To increase the time of MAGD CScL wear, they piggybacked on daily silicone hydrogel lenses of low power (-0.5 D). The patient reported being comfortable with this piggyback system for approximately 15h a day. After 1year of using the piggyback system, visual quality and wearing time were maintained. In addition, no adverse ocular effects were found during this period. This case report shows that in this patient a MAGD CScL could be fitted successfully on a daily silicone hydrogel lens in a piggyback system for keratoconus management, providing good visual quality along with prolonged use times and without adverse effects on the cornea

  2. Compliance among soft contact lens wearers.

    OpenAIRE

    Kuzman, Tomislav; Barišić Kutija, Marija; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurišić, Darija; Škegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-01-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in ...

  3. Panoramic lens applications revisited

    Science.gov (United States)

    Thibault, Simon

    2008-04-01

    During the last few years, innovative optical design strategies to generate and control image mapping have been successful in producing high-resolution digital imagers and projectors. This new generation of panoramic lenses includes catadioptric panoramic lenses, panoramic annular lenses, visible/IR fisheye lenses, anamorphic wide-angle attachments, and visible/IR panomorph lenses. Given that a wide-angle lens images a large field of view on a limited number of pixels, a systematic pixel-to-angle mapping will help the efficient use of each pixel in the field of view. In this paper, we present several modern applications of these modern types of hemispheric lenses. Recently, surveillance and security applications have been proposed and published in Security and Defence symposium. However, modern hemispheric lens can be used in many other fields. A panoramic imaging sensor contributes most to the perception of the world. Panoramic lenses are now ready to be deployed in many optical solutions. Covered applications include, but are not limited to medical imaging (endoscope, rigiscope, fiberscope...), remote sensing (pipe inspection, crime scene investigation, archeology...), multimedia (hemispheric projector, panoramic image...). Modern panoramic technologies allow simple and efficient digital image processing and the use of standard image analysis features (motion estimation, segmentation, object tracking, pattern recognition) in the complete 360° hemispheric area.

  4. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  5. Optical quality for keratoconic eyes with conventional RGP lens and simulated, customised contact lens corrections: a comparison.

    Science.gov (United States)

    Jinabhai, Amit; Neil Charman, W; O'Donnell, Clare; Radhakrishnan, Hema

    2012-05-01

    To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position. The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation. In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies. At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.

  6. Objective lens simultaneously optimized for pupil ghosting, wavefront delivery and pupil imaging

    Science.gov (United States)

    Olczak, Eugene G (Inventor)

    2011-01-01

    An objective lens includes multiple optical elements disposed between a first end and a second end, each optical element oriented along an optical axis. Each optical surface of the multiple optical elements provides an angle of incidence to a marginal ray that is above a minimum threshold angle. This threshold angle minimizes pupil ghosts that may enter an interferometer. The objective lens also optimizes wavefront delivery and pupil imaging onto an optical surface under test.

  7. Contact Lens Wear at Altitude: Subcontact Lens Bubble Formation

    Science.gov (United States)

    1987-11-01

    incidence of (PMMA) lenses . Reported here are the results of contact lens subcontact lens bubble formation under scleral lenses at bubble studies with soft...vision from formation of large bubbles greater than 6,096 m (20,000 It). With soft contact lenses , bubble under their contact lenses . They also found...always located at the limbus and were without sequela to vision or corneal epithelial integrity. scleral lenses used by Jaeckle were permeable to gases

  8. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  9. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  10. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  11. Gabor lens theory

    International Nuclear Information System (INIS)

    Irani, A.A.

    1978-01-01

    The principle of using the space charge of an electron cloud to focus ion beams was first proposed by Gabor. Electrons are to be confined radially by means of an axial magnetic field B/sub z/ and axially by means of externally applied electric fields E/sub z/. An ion beam of charge density n/sub i/ much less than n/sub e/, the electron charge density can then be focused by the radial electric field set up by the electron cloud. The case considered here is that of a hollow cylindrical conductor charged to a potential +V with grounded rings on either side to set up the axial E/sub z/ field. A solenoid wound around the central conductor supplies the B/sub z/ field. Theoretical calculations are carried out for n/sub e/ maximum as a function of B/sub z/ due to radial confinement and V due to axial confinement and the focal length of the Gabor Lens is calculated

  12. [Contact lens care and maintenance].

    Science.gov (United States)

    Bloise, L

    2017-04-01

    All contact lenses with replacement schedules longer than daily must be maintained. At each step of their use, the lenses may be contaminated. Contact lens solutions perform the essential functions of cleaning, decontaminating and preserving the lenses to prevent infectious problems and improve wearing comfort. Contact lens contamination essentially comes from hands, cleaning solutions, cases, water and the environment. The pathogenic microorganisms are mainly Gram-negative bacteria, fungi and amoebae. Contact lens deposits may or may not have an organic origin. Their presence increases the risk of infection because they serve as a nutrient matrix for microbes, and they are responsible for wearing discomfort. Contact lens solutions differ in their composition, their mechanism of action and the concentration of the various agents. To prescribe the best lens care system to each wearer and for each material, it is necessary to be very familiar with them. Maintenance is the main cause of discomfort with contact lenses, either through improper use, solution-material incompatibility, or a reaction of the wearer to the components. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  14. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  15. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection. Despite the low objective compliance rate, self grading was relatively high. Therefore, these results indicate the need for patient

  16. Temporal properties of the lens eyes of the box jellyfish Tripedalia cystophora

    DEFF Research Database (Denmark)

    O'Connor, Megan; Nilsson, Dan-E; Garm, Anders Lydik

    2010-01-01

    Box jellyWsh (Cubomedusae) are visually orientating animals which posses a total of 24 eyes of 4 morphological types; 2 pigment cup eyes (pit eye and slit eye) and 2 lens eyes [upper lens-eye (ule) and lower lens-eye (lle)]. In this study, we use electroretinograms (ERGs) to explore temporal...... properties of the two lens eyes. We Wnd that the ERG of both lens eyes are complex and using sinusoidal Xicker stimuli we Wnd that both lens eyes have slow temporal resolution. The average Xicker fusion frequency (FFF) was found to be approximately 10 Hz for the ule and 8 Hz for the lle. Di......Verences in the FFF and response patterns between the two lens eyes suggest that the ule and lle Wlter information diVerently in the temporal domain and thus are tuned to perform diVerent visual tasks. The data collected in this study support the idea that the visual system of box jellyWsh is a collection of special...

  17. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, Ryan P.; Bellamy, Michael B.; Eckerman, Keith F.

    2011-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

  18. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, R. P.; Bellamy, M. B.; Eckerman, K. F.

    2012-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations. (authors)

  19. Computer-aided lens assembly

    Science.gov (United States)

    Tomlinson, Richard; Alcock, Rob; Petzing, Jon; Coupland, Jeremy

    2004-01-01

    We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet.

  20. Acanthamoeba keratitis. Contact lens and noncontact lens characteristics.

    Science.gov (United States)

    Chynn, E W; Lopez, M A; Pavan-Langston, D; Talamo, J H

    1995-09-01

    To identify potential differences in time to diagnosis and final visual outcome between contact lens and noncontact lens users with Acanthamoeba keratitis. Prior studies have shown early diagnosis and therapy to be related to outcome but have not analyzed differences among patients with and without contact lenses. A retrospective analysis of 11 consecutive cases (involving 13 eyes) of Acanthamoeba keratitis diagnosed at one institution over a 3-year period. Mean time to diagnosis was significantly longer in noncontact lens users versus those who wore contact lenses (mean, 5.8 versus 3.3 weeks). Fifty percent of patients who did not wear contact lenses had a poor outcome (visual acuity worse than 20/40 or penetrating keratoplasty) versus 14% of patients who wore contact lenses. Diagnoses were made later in patients without contact lenses, and these patients had a worse visual outcome than those with Acanthamoeba keratitis who wore contact lenses. All patients with unresponsive microbial keratitis, even those without contact lens use, should be evaluated for Acanthamoeba.

  1. A microcapillary lens for X-rays

    CERN Document Server

    Dudchik, Y I

    1999-01-01

    A new design of a compound refractive lens for X-rays is proposed. The lens is made as a set of glue microlenses placed in a glass capillary. The technique of lens fabrication is described. Results of ray tracing calculations for 8 and 15 keV photons are represented.

  2. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  3. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  4. Spinning pipe gas lens revisited

    CSIR Research Space (South Africa)

    Mafusire, C

    2008-01-01

    Full Text Available , there is little information on optical phase aberrations and no study to date on the propagation parameters of the laser beam, but has rather remained rooted in the domain of ray optics. Researchers revisit the spinning pipe gas lens in this paper with new...

  5. Tube entrance lens focus control

    Science.gov (United States)

    Weisser, D. C.; Fifield, L. K.; Kitchen, T. F. G.; Tunningley, T. B.; Lobanov, N. R.; Muirhead, A. G.

    2013-02-01

    The entrance of the accelerator tube in a large electrostatic accelerator imposes a strong lens that dominates the beam optics. The magnification of the lens is large because of the low injection energy, the high voltage gradient of the acceleration tube and the long distance to the terminal. In the absence of the acceleration, the magnification would produce an unacceptably large beam spot at the terminal. The tyranny of the lens is especially irksome when the accelerator is required to operate at a lower terminal voltage than the one corresponding to the nominal gradient at high voltage. One way around the difficulty, used in NEC Pelletron accelerators, is to insert a series of nylon and steel rods that short together units of the acceleration structure at the terminal leaving the ones near the entrance close to the nominal gradient for optimum transmission. This operation takes time and risks the loss of insulating gas. Another alternative used in the 25URC at Oak Ridge National Laboratory, is to focus the beam at the tube entrance, substantially diluting the effect of the entrance lens. The beam then diverges and so requires an additional lens part way to the terminal. This solution is only partially effective and still necessitates use of shorting rods for low voltage operation. The fact that these elaborate strategies are used is evidence that the alternative of lowering the injection energy as the terminal voltage is lowered imposes enough problems that it is not used in practice. We have modeled a solution that controls the voltage gradient at the tube entrance using an external power supply. This not only maintains the focusing effect of the lens but provides the opportunity to tune the beam by adjusting the entrance lens. A 150 kV power supply outside the pressure vessel feeds a controllable voltage through a high voltage feed-through to the fifth electrode of the accelerator tube. Thus 150 kV on this electrode creates the nominal gradient of 30 kV per

  6. Development of a Laue lens for nuclear astrophysics

    International Nuclear Information System (INIS)

    Rousselle, Julien

    2011-01-01

    prototype, it have been possible to maintain the required precision through the various steps of alignment, mounting and space qualification testing i.e. characterizing the crystal plane orientation, machining the lens support, cementing the crystals on the support, vibration tests, and thermal cycling

  7. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  8. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  9. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  10. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  11. Looking beyond the perfect lens

    International Nuclear Information System (INIS)

    Wee, W H; Pendry, J B

    2010-01-01

    The holy grail of imaging is the ability to see through anything. From the conservation of energy, we can easily see that to see through a lossy material would require lenses with gain. The aim of this paper therefore is to propose a simple scheme by which we can construct a general perfect lens, with gain-one that can restore both the phases and amplitudes of near and far fields.

  12. Zoom lens calibration with zoom- and focus-related intrinsic parameters applied to bundle adjustment

    Science.gov (United States)

    Zheng, Shunyi; Wang, Zheng; Huang, Rongyong

    2015-04-01

    A zoom lens is more flexible for photogrammetric measurements under diverse environments than a fixed lens. However, challenges in calibration of zoom-lens cameras preclude the wide use of zoom lenses in the field of close-range photogrammetry. Thus, a novel zoom lens calibration method is proposed in this study. In this method, instead of conducting modeling after monofocal calibrations, we summarize the empirical zoom/focus models of intrinsic parameters first and then incorporate these parameters into traditional collinearity equations to construct the fundamental mathematical model, i.e., collinearity equations with zoom- and focus-related intrinsic parameters. Similar to monofocal calibration, images taken at several combinations of zoom and focus settings are processed in a single self-calibration bundle adjustment. In the self-calibration bundle adjustment, three types of unknowns, namely, exterior orientation parameters, unknown space point coordinates, and model coefficients of the intrinsic parameters, are solved simultaneously. Experiments on three different digital cameras with zoom lenses support the feasibility of the proposed method, and their relative accuracies range from 1:4000 to 1:15,100. Furthermore, the nominal focal length written in the exchangeable image file header is found to lack reliability in experiments. Thereafter, the joint influence of zoom lens instability and zoom recording errors is further analyzed quantitatively. The analysis result is consistent with the experimental result and explains the reason why zoom lens calibration can never have the same accuracy as monofocal self-calibration.

  13. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  14. Orienteering club

    CERN Multimedia

    Club d'orientation

    2015-01-01

    Course d'orientation La reprise des courses d’orientation était attendue dans la région puisque près de 150 coureurs ont participé à la première épreuve automnale organisée par le club d’orientation du CERN sur le site de La Faucille. Les circuits ont été remportés par Yann Locatelli du club d’Orientation Coeur de Savoie avec 56 secondes d’avance sur Damien Berguerre du club SOS Sallanches pour le parcours technique long, Marie Vuitton du club CO CERN (membre également de l’Equipe de France Jeune) pour le parcours technique moyen avec presque 4 minutes d’avance sur Jeremy Wichoud du club Lausanne-Jorat, Victor Dannecker pour le circuit technique court devant Alina Niggli, Elliot Dannecker pour le facile moyen et Alice Merat sur le facile court, tous membres du club O’Jura. Les résultats comp...

  15. Oriental cholangiohepatitis

    International Nuclear Information System (INIS)

    Scheible, F.W.; Davis, G.B.; California Univ., San Diego, La Jolla

    1981-01-01

    The recent influx of immigrants from Southeast Asia into the United States has increased the likelihood of encountering unusual diseases heretofore rarely seen in this country. Among these disorders is Oriental cholangiohepatitis, a potentially life-threatening process whose early diagnosis is facilitated by roentgenographic findings. Ultrasonography can also provide useful information, although potential pitfalls in diagnosis should be recognized. (orig.)

  16. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  17. Research on one manual zoom liquid lens

    Science.gov (United States)

    Zhao, Cunhua; Shi, Yongpeng; Li, Wenjiao; Li, Congcong

    2011-11-01

    In liquid zoom lens, the accurate fixed-focus location needs the accurate calculation of focal length. That is to say, the accurate calculation of surface curvature must be obtained. Therefore, the research of their relation in liquid zoom lens becomes extremely important which has a directly theoretical instruction for the design of liquid zoom lenses. In our paper, the relation is studied. A manual liquid lens is reported which has upper and nether components with specificaton Φ12×5mm. The zoom lens is obtained by the upper component circumvolving down into the nether components.

  18. Numerical analyses of planer plasmonic focusing lens

    Science.gov (United States)

    Chou, Yen-Yu; Lee, Yeeu-Chang

    2018-03-01

    The use of polystyrene (PS) sphere lithography has been widely applied in the fabrication of micron and nano structures, due to their low cost and ease of fabrication in large scale applications. This study evaluated the feasibility of plasmonic lens base on metal thin films with nanohole structures fabricated by using PS sphere lithography through three-dimensional (3D) finite difference time domain (FDTD) method. We calculated the intensity profile of lens with various wavelength of incident light, lens size, cutting positions, diameters of nanohole, and periods of nanohole to investigate the geometric parameters influence on the focusing properties of the plasmonic lens.

  19. Orientation Club

    CERN Multimedia

    Club d'orientation

    2014-01-01

    COURSE ORIENTATION Résultats de samedi 10 mai    C’est sur une carte entièrement réactualisée dans les bois de Versoix, que plus de 100 coureurs sont venus participer à la course d’orientation, type longue distance, préparée par des membres du club du CERN. Le terrain plutôt plat nécessitait une orientation à grande vitesse, ce qui a donné les podiums suivants :  Technique long avec 17 postes : 1er Jurg Niggli, O’Jura en 52:48, 2e Beat Muller, COLJ Lausanne-Jorat en 58:02, 3e Christophe Vuitton, CO CERN en 58:19 Technique moyen avec 13 postes : 1er Jean-Bernard Zosso, CO CERN, en 46:05 ; 2e Yves Rousselot, Balise 25 Besançon, en 55:11 ; 3e Laurent Merat, O'Jura, en 55:13 Technique court avec 13 postes : 1er Julien Vuitton, CO CERN en 40:59, 2e Marc Baumgartner, CO CERN en 43:18, 3e Yaelle Mathieu en 51:42 Su...

  20. Orienteering Club

    CERN Multimedia

    Club d'orientation

    2013-01-01

    Courses d’orientation ce printemps Le Club d’orientation du CERN vous invite à venir découvrir la course d’orientation et vous propose, en partenariat avec d’autres clubs de la région, une dizaine de courses populaires. Celles-ci ont lieu les samedis après-midi, elles sont ouvertes à tous, quel que soit le niveau, du débutant au sportif confirmé, en famille ou en individuel, en promenade ou en course. Si vous êtes débutant vous pouvez profiter d’une petite initiation offerte par l’organisateur avant de vous lancer sur un parcours. Divers types de parcours sont à votre choix lors de chaque épreuve : facile court (2-3 km), facile moyen (3-5 km), technique court (3-4 km), technique moyen (4-5 km) et technique long (5-7 km). Les dates à retenir sont les suivantes : Samedi 23 mars: Pully (Vd) Samedi 13 avril: Pougny...

  1. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  2. Rapid and accurate assembly method for a new Laue lens prototype

    Science.gov (United States)

    Wade, Colin; Barrière, Nicolas; Hanlon, Lorraine; Boggs, Steven E.; Brejnholt, Nicolai F.; Massahi, Sonny; Tomsick, John A.; von Ballmoos, Peter

    2015-09-01

    The Laue lens is a technology for gamma-ray astrophysics whereby gamma-rays of particular energies can be focused by a suitable arrangement of crystals. The Laue lens assembly station at UC Berkeley was used to build a technological demonstrator addressing the key issues of crystal mounting speed, crystal position and orientation accuracy, and crystal reflectivity. The new prototype is a lens segment containing a total of 48 5 x 5 mm2 crystals - 36 Iron and 12 Aluminium. The segment is composed of 8 partial rings, each of which is aligned to diffract an energy between 95 and 130 keV from a source at 12:5m with a focal length of 1:5 m.

  3. Improving teaching assistants' orientation in a school of nursing: a lean approach.

    Science.gov (United States)

    Aaltonen, Pamela M; Foli, Karen J; Kirby, Kristen F; Simpson, Vicki L; Walters, Becky

    2015-01-01

    Newly hired teaching assistants (TAs) come to schools of nursing with varying levels of experience in academic institutions. Therefore, the orientation of TAs becomes important at a micro level (student instruction) and macro level (mission of the organization). We describe a Lean approach to strengthening TA orientation and reducing waste and inconsistency. Developed solutions and tools through the lens of quality improvement are discussed.

  4. [Acanthamoeba isolation from contact lens solution of contact lens wearers without keratitis].

    Science.gov (United States)

    Watanabe, R; Ishibashi, Y; Hommura, S; Ishii, K

    1994-05-01

    Acanthamoeba keratitis seems to be associated with wearing contact lenses. As controls, we surveyed contact lens wearers without keratitis. Contact lens solutions of 93 persons were examined in order to identify risk factors for contamination by Acanthamoeba. Therefore, the contact lens disinfection system and storage schedules were studied in each case. Acanthamoeba organisms were isolated from 4 specimens (4.3%). The incidence of Acanthamoeba was higher in specimens of soft contact lens solution than in those of hard contact lens solution, and all the Acanthamoeba positive cases had been using tap water.

  5. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  6. Orientation politique

    OpenAIRE

    Tiberj, Vincent

    2012-01-01

    L’orientation politique constitue l’ensemble des valeurs, normes et préférences (bref l’idéologie) qui guide ou structure les individus vers un parti ou un camp politique. Contrairement à une vision philosophique de la politique fondée sur un citoyen idéal à la fois rationnel et insensible aux contingences de sa situation personnelle, l’électeur n’est pas seul quand il se présente dans l’isoloir, il amène avec lui ses groupes d’appartenance, son histoire individuelle et ses valeurs. En cela, ...

  7. Protection of the eye lens

    International Nuclear Information System (INIS)

    2015-01-01

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  8. Color corrected Fresnel lens for solar concentration

    International Nuclear Information System (INIS)

    Kritchman, E.M.

    1979-01-01

    A new linear convex Fresnel lens with its groove side down is described. The design philosophy is similar to the highly concentrating two focal Fresnel lens but including a correction for chromatic aberration. A solar concentration ratio as high as 80 is achieved. For wide acceptance angles the concentration nears the theoretical maximum. (author)

  9. Modified suturing contact lens for penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1978-11-01

    The authors have previously described a suturing contact lens that protects the corneal endothelium by aiding in the maintenance of the anterior chamber during penetrating keratoplasty. This report describes structural modifications of the suturing contact lens, which improve its stability and effectiveness. An additional configuration for use in corneal lacerations is presented.

  10. Charged black lens in de Sitter space

    Science.gov (United States)

    Tomizawa, Shinya

    2018-02-01

    We obtain a charged black lens solution in the five-dimensional Einstein-Maxwell-Chern-Simons theory with a positive cosmological constant. It is shown that the solution obtained here describes the formation of a black hole with the spatial cross section of a sphere from that of the lens space of L (n ,1 ) in five-dimensional de Sitter space.

  11. Contact Lens Use in the Civil Airman Population

    National Research Council Canada - National Science Library

    Nakagawara, Van

    2002-01-01

    ...) aeromedical certificate. Although contact lens technology has advanced dramatically in recent years, the aviation environment may still have adverse effects on contact lens performance in some flight situations...

  12. Orienteering Club

    CERN Multimedia

    Club d'Orientation

    2013-01-01

    Course d’orientation Face aux Championnats de France des Clubs à Poitiers, et à une météo hivernale (vent glaciale et pluie), il ne restait qu’une cinquantaine d’orienteurs pour participer à l’épreuve organisée le samedi 25 mai à Grange-Malval. Les participants ont tout de même bien apprécié les 5 circuits proposés par le Satus Genève. Les résultats sont disponibles sur notre site http://cern.ch/club-orientation. En plus des résultats, vous pourrez noter des informations sur la nouvelle école de CO encadrée par B. Barge, Prof. EPS à Ferney-Voltaire pour les jeunes à partir de 6 ans. La prochaine étape de la coupe genevoise se déroulera samedi 1er juin à Morez (39). Epreuve organisée par le club O’Jura&nb...

  13. Club Orientation

    CERN Multimedia

    Club d'orientation

    2014-01-01

      COURSE ORIENTATION   Pas moins de 100 concurrents sont venus s’affronter sur les parcours proposés par le club d’orientation du CERN ce samedi 26 avril lors de la 4e étape de la coupe genevoise de printemps. Les podiums ont été attribués à :  Technique long avec 19 postes : 1er Yvan Balliot, ASO Annecy en 1:01:39 ; 2e Dominique Fleurent, ASO Annecy, en 1:05:12 ; 3e Rémi Fournier, SOS Sallanches, en 1:05:40. Technique moyen avec 14 postes : 1er Jean-Bernard Zosso, CO CERN, en 46:42 ; 2e Céline Zosso, CO CERN, en 50:51 ; 3e Clément Poncet, O’Jura Prémanon, en 51:27. Technique court avec 13 postes : 1er Jaakko Murtomaki, YKV Seinaejoki, en 36:04 ; 2e Marc Baumgartner en 41:27 ; 3e Natalia Niggli, O’Jura Prémanon, en 52:43. Sur les parcours facile moyen et facile court, victoire respectivement de Stéphanie...

  14. Orienteering club

    CERN Multimedia

    Club d'orientation

    2010-01-01

    Course d’orientation : Coupe Genevoise de printemps 2010 Et c’est reparti pour une nouvelle saison! Pour cette coupe de printemps 2010, le Club d’Orientation du CERN, en partenariat avec d’autres clubs de la région, vous propose le calendrier suivant: – samedi 20 mars : Cossonay (Vd) – samedi 10 avril : Echallens (Vd) – samedi 17 avril : Trélex (Vd) – samedi 24 avril : Genolier (Vd) – samedi 1 mai : Vulbens/Valleiry (74) – samedi 8 mai : Bois de la Rippe (Vd) – samedi 29 mai : Sauvabellin (Vd) : relais – samedi 5 juin: St Cergue (Vd) : grande finale Les courses populaires ont lieu en général le samedi après-midi, elles sont ouvertes à tous, quel que soit le niveau, du débutant au sportif confirmé, en famille ou en individuel, en promenade ou en course. Pour cela, divers types de parcours sont &agr...

  15. Orienteering Club

    CERN Multimedia

    Le Club d’orientation du CERN

    2017-01-01

    Course orientation Les courses d’orientation comptant pour la coupe genevoise de printemps s’enchainent dans la région franco-suisse. Samedi dernier, une bonne centaine de coureurs se sont retrouvés au Mont Mourex où le club du CERN avait préparé la sixième épreuve. A l’issue de la course, les participants confirmaient l’exigence des circuits, à savoir la condition physique et le côté technique du traçage. Le parcours technique long comportant 20 postes a été remporté par Darrell High du Care Vevey en 1:22:38 devançant Beat Muller du COLJ Lausanne-Jorat en 1:25:25 et Alison High également du Care Vevey en 1:28:51. Le circuit technique moyen a été remporté par Christophe Vuitton du CO CERN et le circuit technique court par Claire-Lise Rouiller, CO CERN. Les trois pr...

  16. COURSE ORIENTATION

    CERN Multimedia

    Club d'orientation du CERN

    2015-01-01

      Les coureurs d’orientation de la région se sont donné rendez-vous samedi dernier dans les bois de Pougny/Challex lors de l’épreuve organisée par le club d’orientation du CERN. La carte proposée pour les 5 circuits offrait aussi bien un coté très technique avec un relief pentu qu’un coté avec de grandes zones plates à forêt claire. Le parcours technique long comportant 20 postes a été remporté par Beat Muller du COLJ Lausanne en 56:26 devançant Denis Komarov, CO CERN en 57:30 et Yvan Balliot, ASO Annecy en 57:46. Pour les autres circuits les résultats sont les suivants: Technique moyen (13 postes): 1er Joël Mathieu en 52:32 à une seconde du 2e Vladimir Kuznetsov, COLJ Lausanne-Jorat, 3e Jean-Bernard Zosso, CO CERN, en 54:01 Technique court (12 postes): 1er Lennart Jirden, ...

  17. Orienteering Club

    CERN Multimedia

    Le Club d’orientation du CERN

    2017-01-01

    COURSE ORIENTATION Finale de la coupe d’automne Le club d’orientation du CERN (COC Genève) a organisé sa dernière course populaire de la saison samedi 4 novembre au lieu-dit Les Terrasses de Genève (74). Cette 9e épreuve qui se courait sous la forme d’un One-Man-Relay, clôturait ainsi la coupe genevoise d’automne dont les lauréats sont : Circuit technique long : 1. Julien Vuitton (COC Genève), 2. Berni Wehrle (COC Genève), 3. Christophe Vuitton (COC Genève). Circuit technique moyen : 1. Vladimir Kuznetsov (Lausanne-Jorat), 2. J.-Bernard Zosso (COC Genève), 3. Laurent Merat (O’Jura). Circuit technique court : 1. Thibault Rouiller (COC Genève), 2. exæquo Lennart Jirden (COC Genève) et Katya Kuznetsova (Lausanne-Jorat). Circuit facile moyen : 1. Tituan Barge ...

  18. Orienteering Club

    CERN Multimedia

    Le Club d’orientation du CERN

    2017-01-01

    COURSE ORIENTATION Finale de la coupe d’automne Le club d’orientation du CERN (COC Genève) a organisé sa dernière course populaire de la saison samedi 4 novembre au lieu-dit Les Terrasses de Genève (74). Cette 9e épreuve qui se courait sous la forme d’un One-Man-Relay, clôturait ainsi la coupe genevoise d’automne dont les lauréats sont : Circuit technique long : 1. Julien Vuitton (COC Genève), 2. Berni Wehrle (COC Genève), 3. Christophe Vuitton (COC Genève). Circuit technique moyen : 1. Vladimir Kuznetsov (Lausanne-Jorat), 2. J.-Bernard Zosso (COC Genève), 3. Laurent Merat (O’Jura). Circuit technique court : 1. Thibault Rouiller (COC Genève), 2. exæquo Lennart Jirden (COC Genève) et Katya Kuznetsova (Lausanne-Jorat). Circuit facile moyen : 1. Tituan Barge...

  19. Orienteering Club

    CERN Multimedia

    Le Club d’orientation du CERN

    2017-01-01

    Calendrier des courses de la Coupe Genevoise – printemps 2017 Club d'orientation - Julien,  jeune membre du club. Le Club d’orientation du CERN, en partenariat avec d’autres clubs de la région, vous propose une série de courses populaires, qui se dérouleront des deux côtés de la frontière franco-suisse, à savoir : Samedi 1 avril : Pougny/Challex (01) Samedi 8 avril: Ballens (VD) Samedi 22 avril: Apples (VD) Samedi 29 avril: Mont Mussy (01) Samedi 6 mai: Prémanon (39) Samedi 13 mai: Mont Mourex (01) Samedi 20 mai: Prévondavaux (VD) Samedi 10 juin: Chancy/Valleiry (74) Samedi 17 juin: Trélex - Finale (VD) Ces courses sont ouvertes à tous, quel que soit le niveau, du débutant au sportif confirmé, en famille ou en individuel. Les inscriptions sur un des 5 parcours proposés se font sur place le jour de l...

  20. Orienteering Club

    CERN Multimedia

    Club d'Orientation

    2015-01-01

    Course orientation C’est au pied du Salève, proche du Golf de Bosset, que le club d’orientation du CERN (CO CERN) a organisé samedi 19 septembre une nouvelle épreuve comptant pour la Coupe Genevoise d’automne. La zone « des Terrasses de Genève » avait été cartographiée et mise en service l’année dernière. Les participants ont pu apprécier un terrain ludique avec beaucoup de microreliefs, de points d’eau et de gros rochers, le tout au milieu d’une forêt assez claire et agréable à courir. Sur le parcours technique long, le résultat a été très serré puisque Pierrick Merino du club d’Annecy a gagné avec seulement 9 secondes d’avance sur Gaëtan Vuitton (CO CERN) qui confiait avoir perdu beaucoup du te...

  1. Orienteering Club

    CERN Multimedia

    Club d'orientation

    2010-01-01

    COURSE D’ORIENTATION La finale de la coupe de printemps Après avoir remporté le challenge club, samedi 29 juin lors du relais inter-club à Lausanne, le Club d’orientation du CERN organisait la dernière étape de la coupe genevoise de printemps samedi 5 juin à Saint-Cergue dans les bois de Monteret (Canton de Vaud). Plus de 100 participants se sont déplacés pour venir participer à la finale et découvrir une toute nouvelle carte dans une forêt vallonnée. Les résultats pour chaque circuit de cette étape sont : Technique long : 1. Jurg Niggli du club O’Jura, 2. Clément Poncet, 3. Oystein Midttun. Technique moyen : 1. Zoltan Trocsanyi CO CERN, 2. Christophe Ingold, 3. Christina Falga. Technique court : 1. Pierre-Andre Baum, CARE Vevey, 2. Emese Szunyog, 3. Solène Balay. Facile moyen : 1. Elisa P...

  2. Orienteering club

    CERN Multimedia

    Orienteering Club

    2016-01-01

    Course d'orientation Calendrier des courses d’orientation Coupe genevoise d’automne 2016 Samedi 3 septembre : La Faucille (01) Samedi 10 septembre : Prémanon (39) Samedi 17 septembre : Saint-Cergue (VD) Samedi 24 septembre : Jorat / Corcelles (VD) Samedi 1 octobre: Bière - Ballens (VD) -relais Vendredi 14 octobre : Parc Mon Repos (GE) - nocturne Samedi 15 octobre : Terrasse de Genève (74) Samedi 29 octobre : Bonmont (VD) Samedi 5 novembre : Pomier (74) – one-man-relay - Finale   Courses ouvertes à toutes et à tous, sportifs, familles, débutants ou confirmés, du CERN ou d’ailleurs. Cinq circuits disponibles, ceci va du facile court (2 km) adapté aux débutants et aux enfants jusqu’au parcours technique long de 6 km pour les chevronnés en passant par les parcours facile moyen (4&am...

  3. Orienteering Club

    CERN Multimedia

    Club d'Orientation

    2012-01-01

     Course d’orientation C’est sous un magnifique soleil que s’est tenue la 7e épreuve de la coupe genevoise organisée par le club d’orientation du CERN. Les organisateurs avaient concocté des parcours assez techniques sur le site de La Faucille. Sur le parcours technique long, beau podium avec la victoire de Domenico Lepori (double médaillés aux championnats du monde en 2010 en vétéran) du club Care Vevey en 1:00:23, juste devant Jürg Niggli du club O’Jura en 1:00:56 puis Beat Mueller du club Lausanne-Jorat en 1:04:28. Sur le parcours technique moyen, Franck Longchampt s’est octroyé la première place, sur le parcours technique court, le jeune Julien Vuitton, qui n’a pas tout à fait 11 ans, a remporté son circuit. Coté parcours facile moyen, Victor Kuznetsov a une fois de plus gagn&eacut...

  4. Corrected electrostatic lens systems for ion beams

    International Nuclear Information System (INIS)

    Dalgish, R.L.

    1981-01-01

    Recent work in our laboratory has introduced a new class of electrostatic focus forming element for beams, the ELCO lens. It compares favourably with the electrostatic and magnetic quadrupole elements conventionally used for microbeam formation. The ELCO lens does however have disadvantages associated with apertures and alignment. We have continued with the development of ion beam lenses and have evolved a further class of lens element which eliminates aperture and alignment problems. This new element can be combined like optical lenses into an aberration corrected system. Experimental measurement on the basic lens element has confirmed mathematical analysis of ion trajectories through the element. This mathematical analysis predicts that the basic element can be combined into a corrected lens system for, either: (1) high resolution microprobe formation with intrinsic rastering ability, the spot size limited only by the beam properties; or (2) high quality image formation with large magnification/demagnification ratio and wide angular aperture. (orig.)

  5. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2014-07-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  6. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2013-01-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  7. Orienting hypnosis.

    Science.gov (United States)

    Hope, Anna E; Sugarman, Laurence I

    2015-01-01

    This article presents a new frame for understanding hypnosis and its clinical applications. Despite great potential to transform health and care, hypnosis research and clinical integration is impaired in part by centuries of misrepresentation and ignorance about its demonstrated efficacy. The authors contend that advances in the field are primarily encumbered by the lack of distinct boundaries and definitions. Here, hypnosis, trance, and mind are all redefined and grounded in biological, neurological, and psychological phenomena. Solutions are proposed for boundary and language problems associated with hypnosis. The biological role of novelty stimulating an orienting response that, in turn, potentiates systemic plasticity forms the basis for trance. Hypnosis is merely the skill set that perpetuates and influences trance. This formulation meshes with many aspects of Milton Erickson's legacy and Ernest Rossi's recent theory of mind and health. Implications of this hypothesis for clinical skills, professional training, and research are discussed.

  8. Cuba Through A New Lens

    Directory of Open Access Journals (Sweden)

    Jean Stubbs

    2008-12-01

    Full Text Available [First paragraph] The Origins of the Cuban Revolution Reconsidered. Samuel Farber. Chapel Hill: University of North Carolina Press, 2006. x + 212 pp. (Paper US$ 19.95 Cuba: A New History. Ric hard Gott . New Haven: Yale University Press, 2005. xii + 384 pp. (Paper US$ 17.00 Havana: The Making of Cuban Culture. Antoni Kapcia. Oxford: Berg Publishers, 2005. xx + 236 pp. (Paper US$ 24.95 Richard Gott, Antoni Kapcia, and Samuel Farber each approach Cuba through a new lens. Gott does so by providing a broad-sweep history of Cuba, which is epic in scope, attaches importance to social as much as political and economic history, and blends scholarship with flair. Kapcia homes in on Havana as the locus for Cuban culture, whereby cultural history becomes the trope for exploring not only the city but also Cuban national identity. Farber revisits his own and others’ interpretations of the origins of the Cuban Revolution.

  9. Radiation studies in Lens culinaris

    International Nuclear Information System (INIS)

    Sinha, S.S.N.

    1977-01-01

    Estimation of chromosomal aberrations in flowers of Lens culinaris according to their sequence of development in the plants at 4, 8 and 12 Kr in the M 1 generation, showed that the later formed flowers had smaller percentages of cells with aberrations than those developed earlier. It is suggested that this may be the result of competition between more damaged and less damaged cells during the development of the shoot. There is consequently a decrease of sterility in successive flowers. The numbers of karyotypes taking part in the formation of lower and uppermost flowers were estimated cytologically at 4, 8 and 12 Kr. It was found that more karyotypes were involved in the formation of the lower flowers than in the upper ones. It appeared that at lower doses larger numbers of karyotypes were taking part in the formation of the chimaera than at higher doses. (auth.)

  10. EDITORIAL: Optical orientation Optical orientation

    Science.gov (United States)

    SAME ADDRESS *, Yuri; Landwehr, Gottfried

    2008-11-01

    priority of the discovery in the literature, which was partly caused by the existence of the Iron Curtain. I had already enjoyed contact with Boris in the 1980s when the two volumes of Landau Level Spectroscopy were being prepared [2]. He was one of the pioneers of magneto-optics in semiconductors. In the 1950s the band structure of germanium and silicon was investigated by magneto-optical methods, mainly in the United States. No excitonic effects were observed and the band structure parameters were determined without taking account of excitons. However, working with cuprous oxide, which is a direct semiconductor with a relative large energy gap, Zakharchenya and his co-worker Seysan showed that in order to obtain correct band structure parameters, it is necessary to take excitons into account [3]. About 1970 Boris started work on optical orientation. Early work by Hanle in Germany in the 1920s on the depolarization of luminescence in mercury vapour by a transverse magnetic field was not appreciated for a long time. Only in the late 1940s did Kastler and co-workers in Paris begin a systematic study of optical pumping, which led to the award of a Nobel prize. The ideas of optical pumping were first applied by Georges Lampel to solid state physics in 1968. He demonstrated optical orientation of free carriers in silicon. The detection method was nuclear magnetic resonance; optically oriented free electrons dynamically polarized the 29Si nuclei of the host lattice. The first optical detection of spin orientation was demonstrated by with the III-V semiconductor GaSb by Parsons. Due to the various interaction mechanisms of spins with their environment, the effects occurring in semiconductors are naturally more complex than those in atoms. Optical detection is now the preferred method to detect spin alignment in semiconductors. The orientation of spins in crystals pumped with circularly polarized light is deduced from the degree of circular polarization of the recombination

  11. Microbial contamination of contact lens storage cases and domestic tap water of contact lens wearers.

    Science.gov (United States)

    Üstüntürk, Miray; Zeybek, Zuhal

    2012-11-01

    Contact lenses have been widely used as an alternative to spectacles both in developed and developing countries. However, under certain circumstances, adverse responses can occur during contact lens wear and several microorganisms--including bacteria, fungi, and free living amoebae--can cause several eye infections in wearers. Extended wear of contact lenses is the major risk factor of eye infections such as microbial keratitis, besides contaminated contact lens storage case, contaminated lens care solutions, and inaccurate contact lens handling. In this study, we collected contact lens storage case and domestic tap water samples from 50 asymptomatic contact lens wearers. We determined that total aerobic mesophilic bacteria were isolated in 45 (90 %), Gram negative rod bacteria were isolated in 20 (40 %), Pseudomonas spp. were isolated in 2 (4 %) and fungi were isolated in 18 (36 %) out of 50 contact lens storage cases. Free living amoebae were not detected in investigated contact lens storage cases. At the same time, out of 50, total aerobic mesophilic bacteria were isolated in 34 (68 %), fungi were isolated in 15 (30 %) and free living amoebae were isolated in 15 (30 %) domestic tap water samples. No Gram-negative rod bacteria and Pseudomonas spp. were detected in investigated water samples. Two contact lens case samples and two tap water samples were excluded from the analysis for Pseudomonas spp. for technical reasons. According to our findings, inadequate contact lens maintenance during lens wear may result in the contamination of contact lens storage cases. This situation can lead to severe eye infections in contact lens wearers over time.

  12. Orienteering club

    CERN Multimedia

    Club d'orientation

    2014-01-01

    Course d'orientation C’est sous un beau soleil samedi 4 octobre que s’est déroulée la 6e étape de la Coupe genevoise d’automne organisée par le club. Plus d’une centaine de concurrents provenant de 7 clubs de CO avaient fait le déplacement pour courir sur un des cinq parcours proposés dans les bois de Trélex-Génolier (VD). Le podium est le suivant : Technique long (5,9 km, 19 postes) : 1er Jurg Niggli, O’Jura (1:00:02); 2e Berni Wehrle, CO CERN (1:06:44); 3e Konrad Ehrbar, COLJ (1:07:08) Technique moyen (4,8 km, 18 postes) : 1er Christophe Vuitton, CO CERN (54:25); 2e J.B. Zosso, CO CERN (1:01:19); 3e Jeremy Wichoud, COLJ (1:06:21) Technique court (3,8 km, 14 postes) : 1er Julien Vuitton, CO CERN (36:19); 2e Vladimir Kuznetsov, COLJ (48:47); 3e Natalia Niggli, O’Jura (50:38) Facile moyen (3,2 km, 11 postes) : 1ère Alina Niggli, O&...

  13. Orienteering Club

    CERN Multimedia

    CLUB D'ORIENTATION

    2013-01-01

    Calendrier de la coupe d’automne Le Club d’orientation du CERN, en partenariat avec d’autres clubs de la région, vous propose, pour cette nouvelle coupe d’automne genevoise, une série de 10 courses. Le club du O’Jura donnera le coup d’envoi le samedi 31 août. Les courses s’enchaîneront selon le calendrier suivant : Samedi 31 août : Prémanon (39) - longue distance Samedi 14 septembre : La Faucille (01) - longue distance Samedi 21 septembre : Saint Cergue (VD) - longue distance Samedi 28 septembre : Ballens (VD) - relais Samedi 5 octobre : La Pile (VD) - longue distance Vendredi 11 octobre : Les Evaux (GE) - nocturne Samedi 12 octobre : Grand Jorat, Savigny (VD) - longue distance Samedi 19 octobre : Terrasses de Genève (74) - longue distance Samedi 26 octobre : Prémanon (39) - longue distance Samedi 2 novembre : Bois Tollot (GE) - score - Finale Les &a...

  14. Orienteering club

    CERN Multimedia

    Club d'orientation

    2013-01-01

    Course d'orientation Vers les dernières courses de printemps Une centaine de coureurs se sont déplacés sur le site de la Roche Fendue prés de Morez pour gouter à un des 5 parcours proposés par le club du O’Jura. Le terrain était gras mais que peut-on trouver d’autre avec cette météo! Les vainqueurs de chaque circuit sont : Alina Niggli (O’Jura) facile court, Natalja Niggli (O’Jura) facile moyen, Victor Kuznetsov (COLJ) technique court, Yves Rousselot (Balise 25) technique moyen et pour finir François Gonon (O’Jura) avec une victoire haut la main sur le technique long. Il ne reste plus que deux épreuves pour la coupe genevoise de printemps : à savoir samedi 8 juin, course de type longue distance organisée par le club de Lausanne Jorat (COLJ) dans le bois de Seyte sur Mutrux/Concise, inscription de 12h &...

  15. Orienteering club

    CERN Multimedia

    Club d'orientation

    2010-01-01

    COURSE D’ORIENTATION  De La Rippe à Sauvabellin, la coupe genevoise continue ! Le rendez-vous était donné samedi 8 mai aux amateurs de course d’orientation dans les bois de La Rippe (Canton de Vaud). Cette 6e épreuve était organisée par le Club Satus Grutli de Genève. Il est dommage que les participants n’aient pas été aussi nombreux que lors des dernières courses, les Championnats de France des clubs à Dijon ayant certainement retenus plus d’un compétiteur. La première place est revenue à : – Technique long : Berni Wehrle – Technique moyen : Jean-Bernard Zosso – Technique court : Berni Wehrle – Facile moyen : Peter Troscanyi – Facile court : Claire Droz. Il ne restera plus que deux épreuves ...

  16. Orienteering Club

    CERN Multimedia

    Club d'Orientation

    2012-01-01

    Course d'orientation Ces deux dernières semaines, le club a organisé la troisième puis la quatrième étape de la coupe de printemps, une dans la forêt de Collogny/Moissey près de Vulbens, l’autre vers le parcours vita de Trélex. Les résultats sont: Facile court Vulbens : 1er Léo Lonchampt, O’Jura (16:04), 2e Timothée Bazin (23:07), 3e Francesco Pieri (26:57) Trélex : 1er Noora Maurent (23:11), 2e Sarah Stuber, COLJ (26:51), 3e T. Bazin (28:17) Facile moyen Vulbens : 1er Victor Kuznetsov, CO CERN (25:36), 2e Didier Descourvières (28:03), 3e Konstantinos Haider, CO CERN (36:53) Trélex : 1er V. Kuznetsov, COLJ (38:01), 2e K. Haider, CO CERN (43:15), 3e ex aequo Olivia Nguyen et Sven Vietmeier (58:11) Technique court Vulbens : 1er Benoit Bazin (41:21), 2e Colas Gintzburger (55:12), 3e Nathan Freydoz (55:48) Trélex : 1...

  17. Orienteering Club

    CERN Multimedia

    Club d'Orientation

    2015-01-01

    Course orientation Finale de la coupe genevoise La série des courses de printemps s’est achevée samedi dernier dans les bois de Bonmont (Vaud) avec une épreuve «one-man-relay» organisée par le club. Le vainqueur du parcours technique  long, Yann Locatelli (Club de Chambéry Savoie) a réalisé les deux boucles comportant 24 balises avec presque 6 minutes d’avance sur le second concurrent Domenico Lepori (Club CARE Vevey). Cette dernière étape était aussi décisive pour la désignation des lauréats de la coupe genevoise de printemps, en comptabilisant les 6 meilleurs résultats sur les 10 épreuves. Le podium officiel était donné par le président du club, L. Jirden, qui profitait de l’occasion pour remercier tous les participants et également tous les...

  18. Orienteering Club

    CERN Multimedia

    Club d'Orientation

    2012-01-01

     Finale de la coupe de printemps   La dernière course d’orientation comptant pour la Coupe de printemps a eu lieu samedi dernier dans le village des Rousses et vers le Fort. Il s’agissait d’un sprint organisé par le club O’Jura. Les temps de course ont avoisiné les 20 minutes que ce soit pour le parcours technique moyen ou technique long. Tous les habitués étaient au rendez-vous pour venir consolider ou améliorer leur place au classement. A l’issue de cette course, le classement général de la Coupe de printemps prenant en compte les 6 meilleurs résultats des 9 courses était établi et les lauréats de chaque catégorie sont les suivants: Circuit technique long : 1er Berni Wehrle, 2e Bruno Barge, 3e Edvins Reisons. Circuit technique moyen : 1er Jean-Bernard Zosso, 2e Cédric Wehrl&...

  19. Orienteering Club

    CERN Multimedia

    Club d'orientation

    2013-01-01

    Course d'orientation Le coup d’envoi de la coupe genevoise a été donné samedi 31 août dans les bois de Combe Froide à Prémanon. Plus de 150 coureurs avaient fait le déplacement. Les parcours facile court, facile moyen et technique court ont été remportés par des coureurs du club O’Jura - Ulysse Dannecker, Léo Lonchampt, Franck Lonchampt, le technique moyen par Pekka Marti du club Ol Biel Seeland et le technique long par Térence Risse du CA Rosé – également membre de l’équipe nationale suisse des moins de 20 ans. Pour le club du CERN, les meilleures résultats ont été obtenus pas Emese Szunyog sur technique court et Marie Vuitton sur technique moyen avec une 4e place. La prochaine course aura lieu samedi 14 septembre à La Faucille. Le club propose aussi...

  20. Orienteering club

    CERN Multimedia

    Club d'orientation

    2013-01-01

    Course d'orientation Finale de la coupe genevoise Rapide et méthodique, voilà les qualités dont il fallait faire preuve pour remporter la dernière étape de la coupe organisée par le club du CERN dans les bois de Monteret. Il s’agissait d’une course au score où chaque concurrent disposait d’un temps imparti pour poinçonner le maximum de balises. Le parcours technique a été remporté par Tomas Shellman et le parcours facile par Victor Dannecker. Cette dernière étape était aussi décisive pour la désignation des lauréats de la coupe genevoise de printemps. Les résultats officiels étaient donnés par le président du club, L. Jirden : Circuit Technique Long : Berni Wehrle, Bruno Barge, Edvins Reisons Circuit Technique Moyen : J.-Bernard Zosso, ...

  1. Orienteering Club

    CERN Multimedia

    Club d'Orientation

    2012-01-01

    Relais inter-club/Challenge Carlo Milan Samedi dernier, lors de l’épreuve de course d’orientation organisée par le club du O’Jura, le moteur de la discipline était l’esprit d’équipe, puisqu’il était question d’un relais inter-club avec le Challenge Carlo Milan. Les clubs avaient aligné leurs coureurs soit sur le relais technique (trois participants) soit sur le relais facile (deux participants). Côté O’Jura, il fallait noter la participation de François Gonon, champion du monde 2011, côté club du CERN, Marie et Gaëtan Vuitton, jeunes espoirs du club, devaient préparer la piste pour lancer le dernier relayeur. Côté Lausanne-Jorat, il fallait compter sur le très jeune Viktor Kuznetsov. Les 31 équipes engagées n’ont pas m&ea...

  2. Orienteering Club

    CERN Multimedia

    Club d'orientation

    2013-01-01

    De jour comme de nuit Les amateurs de course d’orientation ont pu s’en donner à cœur joie ce week-end puisqu’ils avaient la possibilité de courir sur deux épreuves en moins de 24 heures. En effet, le club du CERN organisait une course de nuit aux Evaux et la 7e étape de la coupe genevoise se tenait samedi après-midi dans les bois du Grand Jorat à Savigny. Les vainqueurs pour chaque course sont : Technique long CO de nuit: Julien Charlemagne, SOS Sallanches CO samedi: Philipp Khlebnikov, ANCO   Technique moyen CO de nuit: Céline Zosso, CO CERN CO samedi: Pavel Khlebnikov, ANCO Technique court CO de nuit: Colas Ginztburger, SOS Sallanches CO samedi: Victor Kuznetsov, COLJ Lausannne Facile moyen CO de nuit: Gaëtan Rickenbacher, CO CERN CO samedi: Tamas Szoke   Facile court CO de nuit:Oriane Rickenbacher, CO CERN CO samedi: Katya Kuznetsov...

  3. Orienteering Club

    CERN Multimedia

    Club d'Orientation

    2011-01-01

    Course d'orientation Avec la CO en nocturne organisée par le club du CERN vendredi 14 octobre au stade des Eveaux (Ge), et la CO à Savigny (Vd) proposée par le club de Lausanne-Jorat le lendemain, les étapes de la coupe genevoise d’automne s’enchainent rapidement. Il ne reste plus que 3 rendez-vous pour boucler la saison. Les premières places devraient certainement se jouer entre des membres du club du CERN, du O’Jura ou de Lausanne-Jorat. La prochaine course du club est programmée pour samedi 22 octobre à Pomier, près de Cruseilles. L’accueil se fera à partir de 12h30 et les départs s’échelonneront de 13h à 15h. * * * * * * * Nouvelle belle victoire samedi 8 octobre à Saint Cergue du jeune finlandais Ville Keskisaari (COLJ) en 50:56 devant Jürg Niggli (O’Jura) en 1:03:32, et Alexandre...

  4. Orienteering club

    CERN Multimedia

    Club d'orientation

    2013-01-01

    Courses d’orientation Samedi 20 avril, les organisateurs du Club de CO du CERN ont accueilli au Mont Mourex 70 participants qui n’ont pas hésité à venir malgré la forte bise. Berni Wehrle du CO CERN s’est octroyé la première place en 1:04:49 sur le parcours technique long devant Pyry Kettunen du Saynso Juankoski en 1:06:52, la 3e place revenant à Bruno Barge, CO CERN, à 7 secondes. Les autres parcours ont été remportés par : Technique moyen : 1er Jacques Moisset, Chamonix (47:44), 2e Yves Rousselot, Balise 25 Besançon (57:16), 3e Jean-Bernard Zosso, CO CERN (59:28). Technique court : 1er Victor Kuznetsov, COLJ (51:53), 2e Pierrick Collet, CO CERN (1:12:52), 3e Dominique Balay, CO CERN (1:16:04). Pour les parcours facile moyen et facile court, Ralf Nardini et Léa Nicolas, tous deux du CO CERN, terminaient respectivement premier. Voi...

  5. Orienteering club

    CERN Multimedia

    Club d'orientation

    2014-01-01

    Course d'orientation Finale de la coupe d’automne La dernière épreuve de la coupe d’automne organisée par le club s’est déroulée ce samedi 1er novembre avec une course type «one-man-relay» dans la forêt de Trelex (Vd). Les concurrents des circuits techniques devaient parcourir trois boucles et ceux des circuits «faciles» deux boucles, avec changements de carte. Le parcours technique long a été remporté par un membre du club, Berni Wehrle. A l’issue de cette course, le Président du club, L. Jirden annonçait le classement général de la coupe d’automne, basé sur les 6 meilleurs résultats de la saison : Circuit technique long : 1er Juerg Niggli (O’Jura), 2e Berni Wehrle, 3e Beat Mueller. Circuit technique moyen : 1er Laurent Merat (O&r...

  6. Orienteering Club

    CERN Multimedia

    Club d'orientation

    2013-01-01

    Finale de la coupe d’automne La dernière épreuve de la coupe d’automne organisée par le club d’orientation du CERN s’est déroulée ce samedi 2 novembre avec une course au score dans le bois Tollot (GE). Les concurrents disposaient d’un temps imparti pour poinçonner le maximum de balises différemment placées selon le circuit choisi. Juerg Niggli (club O’Jura) a remporté le parcours technique long. A l’issue de cette course, le classement général de la coupe d’automne, basé sur les 6 meilleurs résultats de la saison, est le suivant : Circuit technique long : 1er Juerg Niggli (O’Jura), 2e Bruno Barge, 3e Beat Mueller. Circuit technique moyen : 1er Laurent Merat (O’Jura), 2e Jirden Lennart, 3e Daria Niggli. Circuit technique court : 1er Victor Kuznetsov (COLJ), 2e N...

  7. Orienteering Club

    CERN Multimedia

    Club d'orientation

    2012-01-01

    Finale de la coupe d’automne   La coupe d’automne organisée par le club d’orientation du CERN s’est terminée ce samedi 10 novembre avec une course sprint à Prévessins. C’était la 12e épreuve de la saison. En stage dans la région, Tanya Ryabkina, championne d’Europe en titre et médaillée de bronze en moyenne distance lors des championnats du monde à La Givrine cet été, a fait l’honneur de sa présence et termine 2e à 8 secondes de Trygve Buanes, norvégien du club de Bergen. A l’issue de cette dernière épreuve, le classement général de la coupe d’automne, basé sur les 8 meilleurs résultats de la saison, est ainsi le suivant : Circuit technique long : 1er Jurg Niggli (O&rsqu...

  8. Contact lens compliance among a group of young, university-based lens users in South India.

    Science.gov (United States)

    Noushad, Babu; Saoji, Yeshwant; Bhakat, Premjit; Thomas, Jyothi

    2012-01-01

    To investigate the rate of compliance with the soft contact lens care and maintenance procedures with a focus on contact lens wearing habits, cleaning and disinfecting procedures, and maintenance of lens care accessories in a group of young, university-based contact lens wearers Two hundred and sixteen young soft contact lens wearers with an age range of 18-22 years were selected conveniently from the student population of Manipal University, Manipal, India. After receiving informed consent from the participants, their level of compliance with contact lenses was assessed using a questionnaire. The mean (±SD) age of the participants was 21.86±2.35 years. Out of 216 subjects, only 34% of the lens users were identified to be compliant with the least level of compliance observed in the maintenance of lens care accessories. Conventional users showed significantly (p=0.001) better level of compliance compared to disposable wearers and so did the users who acquired their lenses from clinicians (p=0.001) compared to over-the-counter lens receipt. The gender (p=0.496) and years of experience in contact lens use (p=0.142) did not show any statistically significant difference in the level of compliance. This study demonstrated that non-compliance with lens care procedures among a group of young, university-based soft contact lens wearers is common. The results indicated that all subjects had some degree of non-compliance and the least level of compliance observed in the care of lens accessories.

  9. Tear film physiology and contact lens wear. II. Contact lens-tear film interaction.

    Science.gov (United States)

    Holly, F J

    1981-04-01

    The successful fitting of contact lenses requires the practitioner to take into account many properties of the specific lens type used but the practitioner must also understand patient factors including tear properties, use of appropriate solutions, procedures for lens cleaning, and efficiency of blinking. Selection of appropriate patients, selection of lens type, proper fitting, good maintenance, and training and monitoring of patients increase the probability of achieving success.

  10. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  11. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  12. Development of Fresnel lens for improvement of rear visibility; Shikai kojo Fresnel lens no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K.; Sanada, C.; Tsukino, M. [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    Fresnel lenses have been widely used to increase the visual field around vehicles for drivers. However, internal reflection in these lenses has been an obstacle in producing dear images. This internal glow is generated by incident light from an unexpected direction reflecting on the non-lens surface or radiating from the non-lens surface of the Fresnel lens. The cause of internal glow has been made dear combining louver film with the lens. The newly developed technology removes obstacles in producing dear images by reducing internal glow. 7 figs.

  13. Night Vision Goggles Objectives Lens Focusing Methodology

    National Research Council Canada - National Science Library

    Pinkus, Alan; Task, H. L

    2000-01-01

    ...: interpupillary distance, tilt, eye relief, height, eyepiece and objective lens focus. Currently, aircrew use a Hoffman 20/20 test unit to pre-focus their NVG objective lenses at optical infinity before boarding their aircraft...

  14. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  15. The NSLS-II Multilayer Laue Lens Deposition System

    International Nuclear Information System (INIS)

    Conley, R.; Bouet, N.; Biancarosa, J.; Shen, Q.; Boas, L.; Feraca, J.; Rosenbaum, L.

    2009-01-01

    The NSLS-II(1) program has a requirement for an unprecedented level of x-ray nanofocusing and has selected the wedged multilayer Laue lens(2,3) (MLL) as the optic of choice to meet this goal. In order to fabricate the MLL a deposition system is required that is capable of depositing depth-graded and laterally-graded multilayers with precise thickness control over many thousands of layers, with total film growth in one run up to 100 m thick or greater. This machine design expounds on the positive features of a rotary deposition system(4) constructed previously for MLLs and will contain multiple stationary, horizontally-oriented magnetron sources where a transport will move a substrate back and forth in a linear fashion over shaped apertures at well-defined velocities to affect a multilayer coating.

  16. Contractual considerations in contact lens practice.

    Science.gov (United States)

    Classé, J G

    1986-03-01

    The use of forms in contact lens practice can save time, promote patient education, and reduce the opportunity for legal or economic disputes. The most commonly employed forms are those for contact lens fitting agreements, instructions for care and maintenance of lenses, prepaid service agreements, clinical investigations of investigatory lenses or solutions, and for extended wear patients. Sample forms are utilized for purposes of illustration.

  17. Evolution and the Calcite Eye Lens

    OpenAIRE

    Williams, Vernon L.

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  18. Acute lens-induced glaucomas: A review

    Directory of Open Access Journals (Sweden)

    Syed Shoeb Ahmad

    2017-02-01

    Full Text Available Lens-induced factors are important and common mechanisms causing acute elevation of intraocular pressure. While in most cases, the diagnosis and management are straight-forward, in others it is difficult and can lead to improper procedures, complications and poor visual outcomes. This review was done with the aim of studying the various types of lens-induced glaucomas, classifying them in an easy way to understand manner, their clinical features, current management and future possibilities.

  19. Optical design of transmitter lens for asymmetric distributed free space optical networks

    Science.gov (United States)

    Wojtanowski, Jacek; Traczyk, Maciej

    2018-05-01

    We present a method of transmitter lens design dedicated for light distribution shaping on a curved and asymmetric target. In this context, target is understood as a surface determined by hypothetical optical detectors locations. In the proposed method, ribbon-like surfaces of arbitrary shape are considered. The designed lens has the task to transform collimated and generally non-uniform input beam into desired irradiance distribution on such irregular targets. Desired irradiance is associated with space-dependant efficiency of power flow between the source and receivers distributed on the target surface. This unconventional nonimaging task is different from most illumination or beam shaping objectives, where constant or prescribed irradiance has to be produced on a flat target screen. The discussed optical challenge comes from the applications where single transmitter cooperates with multitude of receivers located in various positions in space and oriented in various directions. The proposed approach is not limited to optical networks, but can be applied in a variety of other applications where nonconventional irradiance distribution has to be engineered. The described method of lens design is based on geometrical optics, radiometry and ray mapping philosophy. Rays are processed as a vector field, each of them carrying a certain amount of power. Having the target surface shape and orientation of receivers distribution, the rays-surface crossings map is calculated. It corresponds to the output rays vector field, which is referred to the calculated input rays spatial distribution on the designed optical surface. The application of Snell's law in a vector form allows one to obtain surface local normal vector and calculate lens profile. In the paper, we also present the case study dealing with exemplary optical network. The designed freeform lens is implemented in commercially available optical design software and irradiance three-dimensional spatial distribution is

  20. Acoustic lens for capacitive micromachined ultrasonic transducers

    Science.gov (United States)

    Chang, Chienliu; Firouzi, Kamyar; Park, Kwan Kyu; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T.

    2014-08-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing.

  1. Acoustic lens for capacitive micromachined ultrasonic transducers

    International Nuclear Information System (INIS)

    Chang, Chienliu; Firouzi, Kamyar; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T; Kyu Park, Kwan

    2014-01-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing. (paper)

  2. LENS: Science Scope and Development Stages

    Science.gov (United States)

    Vogelaar, R. Bruce

    2013-04-01

    The Low-Energy Neutrino Spectroscopy (LENS) experiment will resolve the solar metallicity question via measurement of the CNO neutrino flux, as well as test the predicted equivalence of solar luminosity as measured by photon versus neutrinos. The LENS detector uses charged-current interaction of neutrinos on Indium-115 (loaded in a scintillator, InLS) to reveal the complete solar neutrino spectrum. LENS's optically segmented 3D lattice geometry achieves precise time and spatial resolution and unprecedented background rejection and sensitivity for low-energy neutrino events. This first-of-a-kind lattice design is also suited for a range of other applications where high segmentation and large light collection are required (eg: sterile neutrinos with sources, double beta decay, and surface detection of reactor neutrinos). The physics scope, detector design, and logic driving the microLENS and miniLENS prototyping stages will be presented. The collaboration is actively running programs; building, operating, developing, and simulating these prototypes using the Kimballton Underground Research Facility (KURF). New members are welcome to the LENS Collaboration, and interested parties should contact R. Bruce Vogelaar.

  3. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    Science.gov (United States)

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  4. Acanthamoeba keratitis and contact lens wear.

    Science.gov (United States)

    Lindsay, Richard G; Watters, Grant; Johnson, Richard; Ormonde, Susan E; Snibson, Grant R

    2007-09-01

    Acanthamoeba keratitis is a rare but serious complication of contact lens wear that may cause severe visual loss. The clinical picture is usually characterised by severe pain, sometimes disproportionate to the signs, with an early superficial keratitis that is often misdiagnosed as herpes simplex virus (HSV) keratitis. Advanced stages of the infection are usually characterised by central corneal epithelial loss and marked stromal opacification with subsequent loss of vision. In this paper, six cases of contact lens-related Acanthamoeba keratitis that occurred in Australia and New Zealand over a three-year period are described. Three of the patients were disposable soft lens wearers, two were hybrid lens wearers and one was a rigid gas permeable lens wearer. For all six cases, the risk factors for Acanthamoeba keratitis were contact lens wear with inappropriate or ineffective lens maintenance and exposure of the contact lenses to tap or other sources of water. All six patients responded well to medical therapy that involved topical use of appropriate therapeutic agents, most commonly polyhexamethylene biguanide and propamidine isethionate, although two of the patients also subsequently underwent deep lamellar keratoplasty due to residual corneal surface irregularity and stromal scarring. Despite the significant advances that have been made in the medical therapy of Acanthamoeba keratitis over the past 10 years, prevention remains the best treatment and patients who wear contact lenses must be thoroughly educated about the proper use and care of the lenses. In particular, exposure of the contact lenses to tap water or other sources of water should be avoided.

  5. GOLDEN GRAVITATIONAL LENSING SYSTEMS FROM THE SLOAN LENS ACS SURVEY. I. SDSS J1538+5817: ONE LENS FOR TWO SOURCES ,

    International Nuclear Information System (INIS)

    Grillo, C.; Seitz, S.; Bender, R.; Eichner, T.; Bauer, A.; Lombardi, M.; Gobat, R.

    2010-01-01

    We present a gravitational lensing and photometric study of the exceptional strong lensing system SDSS J1538+5817, identified by the Sloan Lens Advanced Camera for Survey. The lens is a luminous elliptical galaxy at redshift z l = 0.143. Using Hubble Space Telescope public images obtained with two different filters, the presence of two background sources lensed, respectively, into an Einstein ring and a double system is ascertained. Our new spectroscopic observations, performed at the Nordic Optical Telescope, reveal unequivocally that the two sources are located at the same redshift z s = 0.531. We investigate the total (luminous and dark) mass distribution of the lens between 1 and 4 kpc from the galaxy center by means of parametric and non-parametric lensing codes that describe the multiple images as point-like objects. Bootstrapping and Bayesian analyses are performed to determine the uncertainties on the quantities relevant to the lens mass characterization. Several disparate lensing models provide results that are consistent, given the errors, with those obtained from the best-fit model of the lens mass distribution in terms of a singular power-law ellipsoid model. In particular, the lensing models agree on: (1) reproducing accurately the observed positions of the images; (2) predicting a nearly axisymmetric total mass distribution, centered and oriented as the light distribution; (3) measuring a value of 8.11 +0.27 -0.59 x 10 10 M sun for the total mass projected within the Einstein radius of 2.5 kpc; and (4) estimating a total mass density profile slightly steeper than an isothermal one (ρ(r)∝r -2.33 +0.43 -0.20 ). A fit of the Sloan Digital Sky Survey multicolor photometry with composite stellar population models provides a value of 20 +1 -4 x 10 10 M sun for the total mass of the galaxy in the form of stars and of 0.9 +0.1 -0.2 for the fraction of projected luminous over total mass enclosed inside the Einstein radius. By combining lensing (total) and

  6. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    International Nuclear Information System (INIS)

    Konvalina, I.; Muellerova, I.

    2011-01-01

    The cathode lens is an electron optical element in an emission electron microscope accelerating electrons from the sample, which serves as a source for a beam of electrons. Special application consists in using the cathode lens first for retardation of an illuminating electron beam and then for acceleration of reflected as well as secondary electrons, made in the directly imaging low energy electron microscope or in its scanning version discussed here. In order to form a real image, the cathode lens has to be combined with a focusing magnetic lens or a focusing immersion-magnetic lens, as used for objective lenses of some commercial scanning electron microscopes. These two alternatives are compared with regards to their optical properties, in particular with respect to predicted aberration coefficients and the spot size, as well as the optimum angular aperture of the primary beam. The important role of the final aperture size on the image resolution is also presented.

  7. Lens exposure during brain scans using multidetector row CT scanners: methods for estimation of lens dose.

    Science.gov (United States)

    Suzuki, S; Furui, S; Ishitake, T; Abe, T; Machida, H; Takei, R; Ibukuro, K; Watanabe, A; Kidouchi, T; Nakano, Y

    2010-05-01

    Some recent studies on radiation lens injuries have indicated much lower dose thresholds than specified by the current radiation protection guidelines. The purpose of this research was to measure the lens dose during brain CT scans with multidetector row CT and to assess methods for estimating the lens dose. With 8 types of multidetector row CT scanners, both axial and helical scans were obtained for the head part of a human-shaped phantom by using normal clinical settings with the orbitomeatal line as the baseline. We measured the doses on both eyelids by using an RPLGD during whole-brain scans including the orbit with the starting point at the level of the inferior orbital rim. To assess the effect of the starting points on the lens doses, we measured the lens doses by using 2 other starting points for scanning (the orbitomeatal line and the superior orbital rim). The CTDIvols and the lens doses during whole-brain CT including the orbit were 50.9-113.3 mGy and 42.6-103.5 mGy, respectively. The ratios of lens dose to CTDIvol were 80.6%-103.4%. The lens doses decreased as the starting points were set more superiorly. The lens doses during scans from the superior orbital rim were 11.8%-20.9% of the doses during the scans from the inferior orbital rim. CTDIvol can be used to estimate the lens dose during whole-brain CT when the orbit is included in the scanning range.

  8. Symmetric Euler orientation representations for orientational averaging.

    Science.gov (United States)

    Mayerhöfer, Thomas G

    2005-09-01

    A new kind of orientation representation called symmetric Euler orientation representation (SEOR) is presented. It is based on a combination of the conventional Euler orientation representations (Euler angles) and Hamilton's quaternions. The properties of the SEORs concerning orientational averaging are explored and compared to those of averaging schemes that are based on conventional Euler orientation representations. To that aim, the reflectance of a hypothetical polycrystalline material with orthorhombic crystal symmetry was calculated. The calculation was carried out according to the average refractive index theory (ARIT [T.G. Mayerhöfer, Appl. Spectrosc. 56 (2002) 1194]). It is shown that the use of averaging schemes based on conventional Euler orientation representations leads to a dependence of the result from the specific Euler orientation representation that was utilized and from the initial position of the crystal. The latter problem can be overcome partly by the introduction of a weighing factor, but only for two-axes-type Euler orientation representations. In case of a numerical evaluation of the average, a residual difference remains also if a two-axes type Euler orientation representation is used despite of the utilization of a weighing factor. In contrast, this problem does not occur if a symmetric Euler orientation representation is used as a matter of principle, while the result of the averaging for both types of orientation representations converges with increasing number of orientations considered in the numerical evaluation. Additionally, the use of a weighing factor and/or non-equally spaced steps in the numerical evaluation of the average is not necessary. The symmetrical Euler orientation representations are therefore ideally suited for the use in orientational averaging procedures.

  9. Development of Powerhouse Using Fresnel lens

    Directory of Open Access Journals (Sweden)

    Al-Dohani Nawar Saif

    2018-01-01

    Full Text Available Solar energy is an alternative source of renewable energy. Sultanate of Oman government showed initiation on utilization of solar energy for domestic and industrial applications. Fresnel lens is one of the methods to collect maximum energy by gathering heat of the sun in the concentrated form (using solar collectors. Earlier research work discloses that Fresnel lens gave better result in terms of power output and produces lower heat loss as compared to linear –parabolic solar collectors. In this work, development of a proto Fresnel lens power house was made to generate electricity. The focused heat from Fresnel lens was used to heat the molten salt in a heat exchanger to produce the steam. The generated steam was used to rotate the steam engine coupled to a generator. In the current work, a maximum power of 30 W was produced. In addition, comparative study was carried out regarding solar salts and heat exchanger materials to understand the Fresnel powerhouse performance. Overall the present study gave valuable information regarding usage of Fresnel lens for electricity generation in Oman.

  10. Non-compliance in contact lens wear.

    Science.gov (United States)

    Claydon, B E; Efron, N

    1994-10-01

    Non-compliance is emerging as a critical issue in the contact lens field. This problem has been studied at depth in general health care situations and is seen as the responsibility of both practitioner and patient (client) working in a health care partnership. The contact lens practitioner and patient present a specific case for the study of non-compliance in areas such as hygiene, solution use, appointment attendance and wearing times. From 40 to 91% of contact lens patients have been reported as non-complaint in the use of recommended care and maintenance regimens and many of these are confused or ignorant about their behaviour. In order to arrive at a general set of conclusions from the studies published to date, it is important to understand the methodology of each study, it purpose, the definition of non-compliance used and the way the results were analysed and described. This review summarizes the research into non-compliance in the contact lens field to data. A set of general conclusions is drawn and a model for compliance in the context of contact lens practice is proposed.

  11. Spherical aberration in contact lens wear.

    Science.gov (United States)

    Lindskoog Pettersson, A; Jarkö, C; Alvin, A; Unsbo, P; Brautaset, R

    2008-08-01

    The aim of the present studies was to investigate the effect on spherical aberration of different non custom-made contact lenses, both with and without aberration control. A wavefront analyser (Zywave, Bausch & Lomb) was used to measure the aberrations in each subject's right eye uncorrected and with the different contact lenses. The first study evaluated residual spherical aberration with a standard lens (Focus Dailies Disposable, Ciba Vision) and with an aberration controlled contact lens (ACCL) (Definition AC, Optical Connection Inc.). The second study evaluated the residual spherical aberrations with a monthly disposable silicone hydrogel lens with aberration reduction (PureVision, Bausch & Lomb). Uncorrected spherical aberration was positive for all pupil sizes in both studies. In the first study, residual spherical aberration was close to zero with the standard lens for all pupil sizes whereas the ACCL over-corrected spherical aberration. The results of the second study showed that the monthly disposable lens also over-corrected the aberration making it negative. The changes in aberration were statistically significant (plenses. Since the amount of aberration varies individually we suggest that aberrations should be measured with lenses on the eye if the aim is to change spherical aberration in a certain direction.

  12. A lazy way to design infrared lens

    Science.gov (United States)

    Qiu, RongSheng; Wu, JianDong; Chen, LongJiang; Yu, Kun; Pang, HaoJun; Hu, BaiZhen

    2017-08-01

    We designed a compact middle-wave infrared (MWIR) lens with a large focal length ratio (about 1.5:1), used in the 3.7 to 4.8 μm range. The lens is consisted of a compact front group and a re-imaging group. Thanks to the compact front group configuration, it is possible to install a filter wheel mechanism in such a tight space. The total track length of the lens is about 50mm, which includes a 2mm thick protective window and a cold shield of 12mm. The full field of view of the lens is about 3.6°, and F number is less than 1.6, the image circle is about 4.6mm in diameter. The design performance of the lens reaches diffraction limitation, and doesn't change a lot during a temperature range of -40°C +60°C. This essay proposed a stepwise design method of infrared optical system guided by the qualitative approach. The method fully utilize the powerful global optimization ability, with a little effort to write code snippet in optical design software, frees optical engineer from tedious calculation of the original structure.

  13. TESS Lens-Bezel Assembly Modal Testing

    Science.gov (United States)

    Dilworth, Brandon J.; Karlicek, Alexandra

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

  14. Developing a second generation Laue lens prototype: high-reflectivity crystals and accurate assembly

    Science.gov (United States)

    Barrière, Nicolas M.; Tomsick, John A.; Boggs, Steven E.; Lowell, Alexander; von Ballmoos, Peter

    2011-09-01

    Laue lenses are an emerging technology that will enhance gamma-ray telescope sensitivity by one to two orders of magnitude in selected energy bands of the ~100 keV to ~1.5 MeV range. This optic would be particularly well adapted to the observation of faint gamma ray lines, as required for the study of Supernovae and Galactic positron annihilation. It could also prove very useful for the study of hard X-ray tails from a variety of compact objects, especially making a difference by providing sufficient sensitivity for polarization to be measured by the focal plane detector. Our group has been addressing the two key issues relevant to improve performance with respect to the first generation of Laue lens prototypes: obtaining large numbers of efficient crystals and developing a method to fix them with accurate orientation and dense packing factor onto a substrate. We present preliminary results of an on-going study aiming to enable a large number of crystals suitable for diffraction at energies above 500 keV. In addition, we show the first results of the Laue lens prototype assembled using our beamline at SSL/UC Berkeley, which demonstrates our ability to orient and glue crystals with accuracy of a few arcsec, as required for an efficient Laue lens telescope.

  15. Acanthamoeba, bacterial, and fungal contamination of contact lens storage cases.

    Science.gov (United States)

    Gray, T B; Cursons, R T; Sherwan, J F; Rose, P R

    1995-01-01

    BACKGROUND--Microbial corneal infection is the most serious complication of contact lens wear. Contact lens cases are a recognised potential source of pathogens associated with corneal ulcers. METHODS--This survey established the incidence of protozoal, bacterial, and fungal contact lens case contamination in 101 asymptomatic daily wear cosmetic contact lens wearers from a domiciliary contact lens practice. RESULTS--Eighty two (81%) contact lens cases were found to be contaminated, with 19 (19%) sterile. Of all contact lens cases, 78 (77%) grew bacteria, 24 (24%) fungi, and 20 (20%) protozoa. Acanthamoeba spp were isolated from eight (8%) contact lens cases. Fifty six (55%) contact lens cases yielded mixed bacterial contamination. This is the first contact lens case survey in which hydrogen peroxide disinfection was the major method of contact lens disinfection (75% of subjects) and no home made saline was used. All the contaminating organisms were shown to possess the enzyme catalase that breaks down hydrogen peroxide to oxygen and water. The polymicrobial nature of the biofilms found in many contact lens cases is illustrated electron micrographically. CONCLUSION--Based on data from this and previous studies, the authors conclude with recommendations for contact lens wearers: (1) regular scrubbing of contact lens case interior to disrupt biofilms; (2) exposure of contact lens case to very hot water (> or = 70 degrees C) will kill Acanthamoeba contaminants; (3) allow contact lens case to air dry between uses; (4) if hydrogen peroxide disinfection is preferred, use a two step system; (5) replace contact lens case regularly. Images PMID:7626578

  16. Characterization of lens based photoacoustic imaging system

    Directory of Open Access Journals (Sweden)

    Kalloor Joseph Francis

    2017-12-01

    Full Text Available Some of the challenges in translating photoacoustic (PA imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF. Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  17. Freeform micromachining of an infrared Alvarez lens

    Science.gov (United States)

    Smilie, Paul J.; Dutterer, Brian S.; Lineberger, Jennifer L.; Davies, Matthew A.; Suleski, Thomas J.

    2011-02-01

    In 1967, Luis Alvarez introduced a novel concept for a focusing lens whereby two transmitting elements with cubic polynomial surfaces yield a composite lens of variable focal length with small lateral shifts. Computer simulations have demonstrated the behavior of these devices, but fabricating the refractive cubic surfaces of the types needed with adequate precision and depth modulation has proven to be challenging using standard methods, and, to the authors' knowledge, Alvarez lens elements have not been previously machined in infrared materials. Recent developments in freeform diamond machining capability have enabled the fabrication of such devices. In this paper, we discuss the fabrication of freeform refractive Alvarez elements in germanium using diamond micro-milling on a five-axis Moore Nanotech® 350FG Freeform Generator. Machining approaches are discussed, and measurements of surface figure and finish are presented. Initial experimental tests of optical performance are also discussed.

  18. Invited review article: the electrostatic plasma lens.

    Science.gov (United States)

    Goncharov, Alexey

    2013-02-01

    The fundamental principles, experimental results, and potential applications of the electrostatic plasma lens for focusing and manipulating high-current, energetic, heavy ion beams are reviewed. First described almost 50 years ago, this optical beam device provides space charge neutralization of the ion beam within the lens volume, and thus provides an effective and unique tool for focusing high current beams where a high degree of neutralization is essential to prevent beam blow-up. Short and long lenses have been explored, and a lens in which the magnetic field is provided by rare-earth permanent magnets has been demonstrated. Applications include the use of this kind of optical tool for laboratory ion beam manipulation, high dose ion implantation, heavy ion accelerator injection, in heavy ion fusion, and other high technology.

  19. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    The gain of an antenna can be enhanced through the integration of a lens, however this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, with a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB giving a peak gain of about 12.9 dBi at 8.8 GHz.

  20. An "ESA-affordable" Laue-lens

    DEFF Research Database (Denmark)

    Lund, Niels

    2005-01-01

    With ESA's INTEGRAL mission gamma-ray astronomy has advanced to the point where major scientific advances must be expected from detailed studies of the many new point sources. The interest in developing focusing telescopes operating in the soft gamma-ray regime up to 1 MeV is therefore mounting r...... constraints of a specific medium size launch vehicle. The introduction of the lens mass as a primary design driver has some surprising effects for the choice of material for the crystals and new tradeoff considerations are introduced....... rapidly. Telescopes based on Laue diffraction of gamma-rays from crystals appear as one promising route, although the practical difficulties of realizing a large scale Laue lens are certainly not small. In this paper I have attempted to develop an optimized lens design considering the size and mass...

  1. The effectiveness of soft contact lens disinfection systems against Acanthamoeba on the lens surface.

    Science.gov (United States)

    Liedel, K K; Begley, C G

    1996-03-01

    This investigation compared the efficacy of three widely used contact lens disinfection systems against an ocular isolate of Acanthamoeba polyphaga. Twenty-seven worn Ciba NewVues lenses were quartered, heat sterilized and inoculated with Acanthamoeba. Lens quarters were then randomly assigned to three experimental groups, with Group A lenses exposed to cleaner and saline rinse only, Group B to disinfection only, and Group C to both cleaner and disinfection. One quarter of each lens served as a control and the other three quarters were experimental. Quantification of viable Acanthamoeba remaining on the lens was performed after each step of the disinfection process. Group A lenses showed no significant difference between the treatments, or the treatments and the control. Group B lenses demonstrated a significant difference (p = 0.0001) between the treatments and the control. In Group C (cleaning and disinfection), the control lens quarters were significantly different (p = 0.037) from the experimental group, but there was no significant difference between the treatments. All three disinfection regimens were very effective in reducing the number of viable Acanthamoeba on the contact lens surface. In the absence of proper cleaning (Group B), AOSept was the most effective of the three. These results also show the importance of thoroughly rubbing the contact lens surface to decrease the number of Acanthamoeba.

  2. Non-compliance with lens care and maintenance in diabetic contact lens wearers.

    Science.gov (United States)

    O'Donnell, Clare; Efron, Nathan

    2004-11-01

    We hypothesize that diabetic contact lens wearers may represent a special group displaying higher levels of compliance with their lens care regimens as a result of learned behaviour relating to maintenance of their diabetic condition. To test this hypothesis, a prospective, single centre, controlled, masked study was performed whereby 29 diabetic contact lens patients and 29 non-diabetic control subjects were issued with disposable hydrogel contact lenses and a multipurpose lens care regimen. All participants were given identical instruction on lens care and maintenance. Compliance levels were assessed at a 12-month aftercare appointment by demonstration and questionnaire. Twenty-four different aspects of compliance were scored, 12 by observation and 12 by questionnaire report, of which only two showed a significant difference between the diabetic and control groups. Although the combined population of contact lens wearers was generally compliant, there were examples of non-compliance in both groups. Neither the duration of diabetes nor the degree of metabolic control appeared to have a significant effect on compliance. The results suggest that eye care practitioners cannot assume that diabetic patients will be more compliant with contact lens care and maintenance than non-diabetic patients.

  3. Analytic models of plausible gravitational lens potentials

    International Nuclear Information System (INIS)

    Baltz, Edward A.; Marshall, Phil; Oguri, Masamune

    2009-01-01

    Gravitational lenses on galaxy scales are plausibly modelled as having ellipsoidal symmetry and a universal dark matter density profile, with a Sérsic profile to describe the distribution of baryonic matter. Predicting all lensing effects requires knowledge of the total lens potential: in this work we give analytic forms for that of the above hybrid model. Emphasising that complex lens potentials can be constructed from simpler components in linear combination, we provide a recipe for attaining elliptical symmetry in either projected mass or lens potential. We also provide analytic formulae for the lens potentials of Sérsic profiles for integer and half-integer index. We then present formulae describing the gravitational lensing effects due to smoothly-truncated universal density profiles in cold dark matter model. For our isolated haloes the density profile falls off as radius to the minus fifth or seventh power beyond the tidal radius, functional forms that allow all orders of lens potential derivatives to be calculated analytically, while ensuring a non-divergent total mass. We show how the observables predicted by this profile differ from that of the original infinite-mass NFW profile. Expressions for the gravitational flexion are highlighted. We show how decreasing the tidal radius allows stripped haloes to be modelled, providing a framework for a fuller investigation of dark matter substructure in galaxies and clusters. Finally we remark on the need for finite mass halo profiles when doing cosmological ray-tracing simulations, and the need for readily-calculable higher order derivatives of the lens potential when studying catastrophes in strong lenses

  4. Photonic crystal based polarization insensitive flat lens

    Science.gov (United States)

    Turduev, M.; Bor, E.; Kurt, H.

    2017-07-01

    The paper proposes a new design of an inhomogeneous artificially created photonic crystal lens structure consisting of annular dielectric rods to efficiently focus both transverse electric and transverse magnetic polarizations of light into the same focal point. The locations of each individual cell that contains the annular dielectric rods are determined according to a nonlinear distribution function. The inner and outer radii of the annular photonic dielectric rods are optimized with respect to the polarization insensitive frequency response of the transmission spectrum of the lens structure. The physical background of the polarization insensitive focusing mechanism is investigated in both spatial and frequency domains. Moreover, polarization independent wavefront transformation/focusing has been explored in detail by investigating the dispersion relation of the structure. Corresponding phase index distribution of the lens is attained for polarization insensitive normalized frequency range of a/λ  =  0.280 and a/λ  =  0.300, where a denotes the lattice constant of the designed structure and λ denotes the wavelength of the incident light. We show the wave transformation performance and focal point movement dynamics for both polarizations of the lens structure by specially adjusting the length of the structure. The 3D finite-difference time domain numerical analysis is also performed to verifiy that the proposed design is able to focus the wave regardless of polarization into approximately the same focal point (difference between focal distances of both polarizations stays below 0.25λ) with an operating bandwidth of 4.30% between 1476 nm and 1541 nm at telecom wavelengths. The main superiorities of the proposed lens structure are being all dielectric and compact, and having flat front and back surfaces, rendering the proposed lens design more practical in the photonic integration process in various applications such as optical switch

  5. Effect of infrared radiation on the lens

    Directory of Open Access Journals (Sweden)

    Aly Eman

    2011-01-01

    Full Text Available Background: Infrared (IR radiation is becoming more popular in industrial manufacturing processes and in many instruments used for diagnostic and therapeutic application to the human eye. Aim : The present study was designed to investigate the effect of IR radiation on rabbit′s crystalline lens and lens membrane. Materials and Methods: Fifteen New Zealand rabbits were used in the present work. The rabbits were classified into three groups; one of them served as control. The other two groups were exposed to IR radiation for 5 or 10 minutes. Animals from these two irradiated groups were subdivided into two subgroups; one of them was decapitated directly after IR exposure, while the other subgroup was decapitated 1 hour post exposure. IR was delivered from a General Electric Lamp model 250R 50/10, placed 20 cm from the rabbit and aimed at each eye. The activity of Na + -K + ATPase was measured in the lens membrane. Soluble lens proteins were extracted and the following measurements were carried out: estimation of total soluble protein, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE and Fourier transform infrared (FTIR spectroscopy. For comparison between multiple groups, analysis of variance was used with significance level set at P < 0.001. Results: The results indicated a change in the molecular weight of different lens crystalline accompanied with changes in protein backbone structure. These changes increased for the groups exposed to IR for 10 minutes. Moreover, the activity of Na + -K + ATPase significantly decreased for all groups. Conclusions: The protein of eye lens is very sensitive to IR radiation which is hazardous and may lead to cataract.

  6. The corneal stroma during contact lens wear.

    Science.gov (United States)

    Jalbert, Isabelle; Stapleton, Fiona

    2005-03-01

    Recent technological advances have lead to novel descriptions of the microanatomy of the corneal stroma. In the first section of this review, these findings and the role they play in the maintenance of vital properties such as corneal transparency, mechanical strength, homeostasis, wound-healing response and metabolism are described. In the second part, contact lens induced stromal alterations such as acidosis, oedema, striae, thinning and opacities are reviewed as well as the more recently described phenomenon of microdot deposits and keratocyte loss with an emphasis on how lens wearing stromal effects can be minimised.

  7. Sterilization potential of contact lens solutions

    Directory of Open Access Journals (Sweden)

    Dada Vijay

    1988-01-01

    Full Text Available In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. It was observed that the contact lens solutions available ir, the domestic market were not upto the mark Suggestions for improvement have also been made.

  8. Rotman lens for mm-wavelengths

    Science.gov (United States)

    Hall, Leonard T.; Hansen, Hedley J.; Abbott, Derek

    2002-11-01

    The 77 GHz band has been reserved for intelligent cruise control in luxury cars and some public transport services in America and the United Kingdom. The Rotman lens offers a cheap and compact means to extend the single beam systems generally used, to fully functional beam staring arrangements. Rotman lenses have been built for microwave frequencies with limited success. The flexibility of microstrip transmission lines and the advent of fast accurate simulation packages allow practical Rotman lenses to be designed at mm-wavelengths. This paper discusses the limitations of the conventional design approach and predicts the performance of a new Rotman lens designed at 77 GHz.

  9. Pulse transformer for the AA lithium lens

    CERN Document Server

    CERN PhotoLab

    1980-01-01

    The antiprotons emanating from the target were initially focused by a magnetic horn. Later on, a Li-lens was used during operation for the SPS collider, until 1992. A Li-rod (130 mm long, 34 mm in diameter) constituted the secondary of a 1:23 pulse-transformer. The half-sine pulse rose to 1000 kA in 900 microsec. The angular acceptance was 95 mrad. In operation after 1992, for LEAR only, a more modest Li-lens was used (155 mm long, diameter 20 mm, 480 kA, risetime 240 microsec, angular acceptance 75 mrad).

  10. Immunochemical analyses of soluble lens proteins in some marine fishes

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.

    Soluble eye lens proteins of 10 fishes, belonging to the families Clupeidae, Hemirhamphidae, Lactaridae, Scombridae, Stromatidae, Psettodidae, Bothidae and Soleidae were studied by immunoelectrophoresis using the lens antiserum of Sardinella...

  11. IOL Implants: Lens Replacement and Cataract Surgery (Intraocular Lenses)

    Science.gov (United States)

    ... Cataract Surgery vs. Laser-Assisted Cataract Surgery Cataract Vision Simulator Cataract Pictures and Videos: What Do ... Mar. 27, 2018 An intraocular lens (or IOL) is a tiny, artificial lens for the eye. It replaces the eye's ...

  12. Lens autofluorescence is not increased at high altitude

    DEFF Research Database (Denmark)

    Kessel, Line; Kofoed, Peter Kristian; Zubieta-Calleja, Gustavo

    2010-01-01

    PURPOSE: To study the relation between ambient environmental ultraviolet radiation exposure and lens fluorescence. METHODS: Non-invasive lens fluorometry measurements were compared in healthy Bolivian and Danish subjects. Background ultraviolet radiation was 4.5 times higher in Bolivia than in De...... living at sea level at 55 degrees northern latitude. These results suggest that lens ageing, as assessed by lens autofluorometry, is independent of exposure to ultraviolet radiation....

  13. 21 CFR 886.1420 - Ophthalmic lens gauge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic lens gauge. 886.1420 Section 886.1420...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1420 Ophthalmic lens gauge. (a) Identification. An ophthalmic lens gauge is a calibrated device intended to manually measure the curvature of a...

  14. In vivo study of lens regeneration in Rana cyanophlyctis under ...

    African Journals Online (AJOL)

    SAM

    2014-03-12

    Mar 12, 2014 ... enhanced the percentage lens regeneration not only in young tadpoles but also in froglets. Lens regeneration ability ... Influence of vitamin A and ascorbic acid on lens regeneration in young, mature tadpoles and froglets of the frog Rana cyanophlyctis. Group .... ingested by macrophages. Dorsal iris cells ...

  15. 21 CFR 800.10 - Contact lens solutions; sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  16. Initial Experience With Posterior Chamber Intraocular Lens Implant ...

    African Journals Online (AJOL)

    The results of extracapsular cataract extraction with posterior chamber intraocular lens implant at the Jos University Teaching Hospital are reviewed. The results suggest that despite lack of facilities to calculate the lens power for emmetropia, the use of a standard lens of about 19.0D will provide a good number of our ...

  17. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Solar powered desalination system using Fresnel lens

    Science.gov (United States)

    Sales, M. T. B. F.

    2016-11-01

    The Philippines is surrounded by coastal areas and these areas can be a potential source for potable water. This study aims to design and construct a solar powered desalination system using Fresnel lens. The experimental study was conducted using polluted salt water for the sample and desalination was carried out using the designed system. The desalination system was composed of the solar concentrator, solar still and the condenser system. The Fresnel lens was made of acrylic plastic and was an effective solar concentrator. Solar stills made of dark colored glass bottles were effective in absorbing the solar energy. The condenser system made of polybutylene and polystyrene were effective in condensing the vapor at ambient temperature. The shortest time of vaporization of the salt water was at 293 sec and the optimum angle of position of the lens was 36.42°. The amount of condensate collected was directly proportional to the amount of salt water in the solar still. The highest mean efficiency of the designed set-up was 34.82%. The water produced by the solar powered desalination system using Fresnel lens passed the standards set by WHO (World Health Organization) for drinking water.

  19. Electronic states in a quantum lens

    International Nuclear Information System (INIS)

    Rodriguez, Arezky H.; Trallero-Giner, C.; Ulloa, S. E.; Marin-Antuna, J.

    2001-01-01

    We present a model to find analytically the electronic states in self-assembled quantum dots with a truncated spherical cap (''lens'') geometry. A conformal analytical image is designed to map the quantum dot boundary into a dot with semispherical shape. The Hamiltonian for a carrier confined in the quantum lens is correspondingly mapped into an equivalent operator and its eigenvalues and eigenfunctions for the corresponding Dirichlet problem are analyzed. A modified Rayleigh-Schro''dinger perturbation theory is presented to obtain analytical expressions for the energy levels and wave functions as a function of the spherical cap height b and radius a of the circular cross section. Calculations for a hard wall confinement potential are presented, and the effect of decreasing symmetry on the energy values and eigenfunctions of the lens-shape quantum dot is studied. As the degeneracies of a semicircular geometry are broken for b≠a, our perturbation approach allows tracking of the split states. Energy states and electronic wave functions with m=0 present the most pronounced influence on the reduction of the lens height. The method and expressions presented here can be straightforwardly extended to deal with more general Hamiltonians, including strains and valence-band coupling effects in Group III--V and Group II--VI self-assembled quantum dots

  20. Surgical treatment of hereditary lens subluxations.

    Science.gov (United States)

    Ozdek, Sengul; Sari, Ayca; Bilgihan, Kamil; Akata, Fikret; Hasanreisoglu, Berati

    2002-01-01

    To evaluate the effectiveness and results of pars plana vitreolensectomy approach with transscleral fixation of intraocular lens in hereditary lens subluxations. Fifteen eyes of 9 consecutive patients with a mean age of 12.8+/-6.2 years (6-26 years) with hereditary lens subluxation were operated on and the results were evaluated in a prospective study. Surgery was considered if best spectacle corrected visual acuity (BSCVA) was less than 20/70. All eyes underwent a 2-port pars plana vitreolensectomy and transscleral fixation of an intraocular lens (IOL). The mean follow-up period was 12.6+/-7.5 months (6-22 months). There was no major intraoperative complication. Preoperatively, 8 eyes (53.3%) had a BSCVA of counting fingers (CF) and 7 eyes (46.6%) had a BSCVA of 20/200 to 20/70. Postoperatively, 14 eyes (93.3%) had a BSCVA of 20/50 or better. None of the patients had IOL decentration or intraocular pressure (IOP) increase during the follow-up period. There was a macular hole formation in 1 eye postoperatively. The early results of pars plana vitreolensectomy with IOL implantation using scleral fixation technique had shown that it not only promises a rapid visual rehabilitation but it is also a relatively safe method. More serious complications, however, may occur in the long term.

  1. READING SCRIPTURE THROUGH A MYSTICAL LENS

    African Journals Online (AJOL)

    Reading scripture through a mystical lens. 144 the illuminatory function of scripture which confirms and explains experience, rather than in its philological or scientific status. Elisabeth often juxtaposes several texts when quoting from memory and the biblical foundation of her writings is clearly evident in certain cases which ...

  2. Corneal ring infiltration in contact lens wearers

    Directory of Open Access Journals (Sweden)

    Seyed Ali Tabatabaei

    2017-01-01

    Full Text Available To report a case of atypical sterile ring infiltrates during wearing soft silicone hydrogel contact lens due to poor lens care. A 29-year-old woman presented with complaints of pain, redness, and morning discharge. She was wearing soft silicone hydrogel contact lens previously; her current symptoms began 1 week before presentation. On examination, best-corrected visual acuity was 20/40 in that eye. Slit-lamp examination revealed dense, ring-shaped infiltrate involving both the superficial and deep stromal layers with lucid interval to the limbus, edema of the epithelium, epithelial defect, and vascularization of the superior limbus. Cornea-specific in vivo laser confocal microscopy (Heidelberg Retina Tomograph 2 Rostock Cornea Module, HRT 2-RCM, Heidelberg Engineering GmbH, Dossenheim, Germany revealed Langerhans cells and no sign of Acanthamoeba or fungal features, using lid scraping and anti-inflammatory drops; her vision completely recovered. We reported an atypical case of a sterile corneal ring infiltrate associated with soft contact lens wearing; smear, culture, and confocal microscopy confirmed a sterile inflammatory reaction.

  3. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    Czech Academy of Sciences Publication Activity Database

    Konvalina, Ivo; Müllerová, Ilona

    2011-01-01

    Roč. 645, č. 1 (2011), s. 55-59 ISSN 0168-9002 R&D Projects: GA ČR GAP102/10/1410; GA AV ČR IAA100650902; GA MŠk ED0017/01/01 Institutional research plan: CEZ:AV0Z20650511 Keywords : cathode lens * compound objective lens * aberration coefficients * spot size * field calculations Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.207, year: 2011

  4. Intrinsic lens potential of neural retina inhibited by Notch signaling as the cause of lens transdifferentiation.

    Science.gov (United States)

    Iida, Hideaki; Ishii, Yasuo; Kondoh, Hisato

    2017-01-15

    Embryonic neural retinas of avians produce lenses under spreading culture conditions. This phenomenon has been regarded as a paradigm of transdifferentiation due to the overt change in cell type. Here we elucidated the underlying mechanisms. Retina-to-lens transdifferentiation occurs in spreading cultures, suggesting that it is triggered by altered cell-cell interactions. Thus, we tested the involvement of Notch signaling based on its role in retinal neurogenesis. Starting from E8 retina, a small number of crystallin-expressing lens cells began to develop after 20 days in control spreading cultures. By contrast, addition of Notch signal inhibitors to cultures after day 2 strongly promoted lens development beginning at day 11, and a 10-fold increase in δ-crystallin expression level. After Notch signal inhibition, transcription factor genes that regulate the early stage of eye development, Prox1 and Pitx3, were sequentially activated. These observations indicate that the lens differentiation potential is intrinsic to the neural retina, and this potential is repressed by Notch signaling during normal embryogenesis. Therefore, Notch suppression leads to lens transdifferentiation by disinhibiting the neural retina-intrinsic program of lens development. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Possible Selves: Students Orientating Themselves towards the Future through Extracurricular Activity

    Science.gov (United States)

    Stevenson, Jacqueline; Clegg, Sue

    2011-01-01

    This paper explores the under-researched area of extracurricular activity undertaken by students through the lens of the possible selves literature, which has largely been developed in the North American context. In the UK the employability agenda assumes an orientation towards the future and employers are increasingly expecting students to…

  6. Nanosecond KTN varifocal lens without electric field induced phase transition

    Science.gov (United States)

    Zhu, Wenbin; Chao, Ju-Hung; Chen, Chang-Jiang; Campbell, Adrian; Henry, Michael; Yin, Stuart (Shizhuo); Hoffman, Robert C.

    2017-08-01

    This paper presents a nanosecond speed KTN varifocal lens. The tuning principle of varifocal lens is based on the high-speed refractive index modulation from the nanosecond speed tunable electric field. A response time on the order of nanoseconds was experimentally demonstrated, which is the fastest varifocal lens reported so far. The results confirmed that the tuning speed of the KTN varifocal lens could be significantly increased by avoiding the electric field induced phase transition. Such a nanosecond speed varifocal lens can be greatly beneficial for a variety of applications that demand high speed axial scanning, such as high-resolution 3D imaging and high-speed 3D printing.

  7. Acid phosphatase and lipid peroxidation in human cataractous lens epithelium

    Directory of Open Access Journals (Sweden)

    Vasavada Abhay

    1993-01-01

    Full Text Available The anterior lens epithelial cells undergo a variety of degenerative and proliferative changes during cataract formation. Acid phosphatase is primarily responsible for tissue regeneration and tissue repair. The lipid hydroperoxides that are obtained by lipid peroxidation of polysaturated or unsaturated fatty acids bring about deterioration of biological membranes at cellular and tissue levels. Acid phosphatase and lipid peroxidation activities were studied on the lens epithelial cells of nuclear cataract, posterior subcapsular cataract, mature cataract, and mixed cataract. Of these, mature cataractous lens epithelium showed maximum activity for acid phosphatase (516.83 moles of p-nitrophenol released/g lens epithelium and maximum levels of lipid peroxidation (86.29 O.D./min/g lens epithelium. In contrast, mixed cataractous lens epithelium showed minimum activity of acid phosphatase (222.61 moles of p-nitrophenol released/g lens epithelium and minimum levels of lipid peroxidation (54.23 O.D./min/g lens epithelium. From our study, we correlated the maximum activity of acid phosphatase in mature cataractous lens epithelium with the increased areas of superimposed cells associated with the formation of mature cataract. Likewise, the maximum levels of lipid peroxidation in mature cataractous lens epithelium was correlated with increased permeability of the plasma membrane. Conversely, the minimum levels of lipid peroxidation in mixed cataractous lens epithelium makes us presume that factors other than lipid peroxidation may also account for the formation of mixed type of cataract.

  8. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    Science.gov (United States)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  9. Subjective assessment of contact lens wear by army aircrew.

    Science.gov (United States)

    Lattimore, M R; Cornum, R L

    1993-07-01

    Because 23% of Army aviators are ametropic, contact lenses have drawn increased attention as a spectacle substitute to solve system compatibility problems. From November 1988 until October 1991, a series of contact lens research protocols were conducted to develop a comprehensive database on contact lens wear in varied environments. Questionnaires were used to assess suitability and acceptability of routine contact lens wear. Responses from 202 subjects were obtained from September 1989 through September 1991. The questions explored operational and safety of flight issues of contact lens wear. Subjects overwhelmingly approved of contact lens use in all settings: 95% expressed greater combat readiness and effectiveness with contact lenses, 98% felt contact lens use (and maintenance) in the cockpit had no adverse impact on safety of flight, and 98% endorsed the routine use of contact lenses. These data highlight Army aircrew acceptance of contact lens use.

  10. Pars Plana Vitrectomy in Treatment of Lens Injury

    Directory of Open Access Journals (Sweden)

    Remzi Avcı

    2013-01-01

    Full Text Available Lens injury due to traumas may present as loss of capsule integrity, cataract, lens subluxation, or lens luxation. In addition, lens subluxation and lens luxation may occur in pseudophakic patients due to trauma. Clear corneal, scleral or sclero-corneal phacoemulsification surgery, pars plana vitrectomy, pars plana vitrectomy with phaco-fragmentation, or pars plana vitrectomy with removal through corneal incision techniques are used in the treatment of lens injury due to traumas. Intraocular lens can be implanted in the bag, sulcus, or anterior chamber during the surgery. Depending on the circumstances, scleral fixated intraocular lenses or iris-claw lenses may also be preferred. Rehabilitation of such patients is not of a great concern today, with the advanced level of vitreoretinal surgery and cataract surgery techniques and with the current state of technology. (Turk J Ophthalmol 2013; 43: 51-4

  11. Entrepreneurial orientation, market orientation, and competitive environment

    DEFF Research Database (Denmark)

    Sørensen, Hans Eibe; Cadogan, John W.

    orientation, and competitive environment shape business performance via a three-way interaction. We test the model using primary data from the CEOs of 270 CEO of manufacturing firms, together with secondary data on these firms' profit performance. An assessment of the results indicates that customer...... orientation moderates the positive relationships between the competitiveness element of entrepreneurial orientation and market share and return on assets (ROA): the positive relationships between competitiveness and market share and competitiveness and ROA become stronger the greater the firms' customer...... orientations. Also, these moderating effects are stronger for firms operating in highly competitive environments. For the innovativeness component of entrepreneurship, however, the positive relationship between innovativeness and ROA decreases as the competitive environment becomes more hostile....

  12. Spontaneous dislocation of lens bag with acrylic lens after uneventful cataract surgery - unusual complication of cataract surgery.

    Science.gov (United States)

    Shah, Mehul A; Shah, Shreya M; Mehta, Ruchir; Shah, Prerna

    2015-01-01

    Spontaneous dislocation of intraocular lens with bag is rare. We report a case of a 56-year-old male who presented with spontaneous anterior dislocation of an in-the-bag intraocular lens 3 years after manual small incision cataract surgery. He had undergone manual small incision cataract surgery with foldable acrylic intraocular lens implantation, and 18 months after cataract surgery ND: YAG capsulotomy with uneventful post capsulotomy follow-up. 17 months after capsulotomy, the patient presented with sudden decrease of vision. On anterior segment examination, the intraocular lens with bag was dislocated into the anterior chamber. It was managed with intraocular lens explantation with bag, anterior vitrectomy and sclera fixated intraocular lens. Spontaneous intraocular lens dislocation with bag is possible after 1.5 years of uneventful surgery which may be managed using different techniques.

  13. Gravitational Lens Time Delays Using Polarization Monitoring

    Directory of Open Access Journals (Sweden)

    Andrew Biggs

    2017-11-01

    Full Text Available Gravitational lens time delays provide a means of measuring the expansion of the Universe at high redshift (and therefore in the ‘Hubble flow’ that is independent of local calibrations. It was hoped that many of the radio lenses found in the JVAS/CLASS survey would yield time delays as these were selected to have flat spectra and are dominated by multiple compact components. However, despite extensive monitoring with the Very Large Array (VLA, time delays have only been measured for three of these systems (out of 22. We have begun a programme to reanalyse the existing VLA monitoring data with the goal of producing light curves in polarized flux and polarization position angle, either to improve delay measurements or to find delays for new sources. Here, we present preliminary results on the lens system B1600+434 which demonstrate the presence of correlated and substantial polarization variability in each image.

  14. Complications caused by contact lens wearing.

    Science.gov (United States)

    Beljan, Jasna; Beljan, Kristina; Beljan, Zdravko

    2013-04-01

    Complications in wearing contact lenses are very rare and caused by poor maintenance, over-extended wear and wearing of contact lenses in a polluted environment. Regular control by a professional person can efficiently reduce the number of complications. This paper describes the most common risks factors for complications, and complications of wearing contact lenses with the classification according to the anatomic parts of the eye: eyelids, tear film, limbus, corneal epithelium, corneal stroma and corneal endothelium. Every complication has been described by the characteristic signs and symptoms, etiology and pathology, as well as therapy and prognosis. The paper describes how to select adequate customers as contact lens users, with proper education in order to ensure minimal incidence of complications due to contact lens wear, thus attracting a lot of satisfied and healthy customers.

  15. Effects of Temperature on Hybrid Lens Performance

    Science.gov (United States)

    Askins, Steve; Victoria, Marta; Herrero, Rebeca; Domínguez, César; Antón, Ignacio; Sala, Gabriel

    2011-12-01

    In hybrid Silicone-on-glass Fresnel lenses, an optical silicone is molded onto a glass substrate and forms the Fresnel structure. These lenses offer a cost effective solution as a primary optical element in point-focus concentrator photovoltaic modules, as well as performance advantages. However, these lenses have a high performance variation with temperature due both to the change in index of refraction of silicone as well as to deformations in the facets caused by coefficient of thermal expansion (CTE) mismatch. In this study we perform measurements of the light flux at the focal plane of a family of SOG lenses, varying temperature and lens-to-receiver distances. The effect of varying silicone cure temperature and the depth of the silicone between the lens and the glass substrate on temperature dependence was investigated. A preliminary computer model of this behavior is presented.

  16. A Tribute to Dr. Willy Lens

    Directory of Open Access Journals (Sweden)

    Maarten Vansteenkiste

    2016-07-01

    Full Text Available Dr. Willy Lens, born on December 10th, 1943, passed away on August 29th, 2014. With his passing, the motivation community has lost a seminal member, a mentor, and a friend. Dr. Lens – a Fellow of the Association for Psychological Science and Founding Fellow of the American Educational Research Association – made fundamental contributions to the study of motivation both through his own work and through his caring and thoughtful mentorship of a large community of scholars. With this tribute, we want to honor Dr. Willy Lens’ significance to psychology and education as well as his positive influence, both personally and professionally, on the lives of dozens of scholars. With his contagious enthusiasm and caring mentorship, Willy was an example for our academic community and with this tribute we express our gratitude for the privilege to have collaborated with him.

  17. Stretched Lens Array Photovoltaic Concentrator Technology Developed

    Science.gov (United States)

    Piszczor, Michael F., Jr.; O'Neill, Mark J.

    2004-01-01

    Solar arrays have been and continue to be the mainstay in providing power to nearly all commercial and government spacecraft. Light from the Sun is directly converted into electrical energy using solar cells. One way to reduce the cost of future space power systems is by minimizing the size and number of expensive solar cells by focusing the sunlight onto smaller cells using concentrator optics. The stretched lens array (SLA) is a unique concept that uses arched Fresnel lens concentrators to focus sunlight onto a line of high-efficiency solar cells located directly beneath. The SLA concept is based on the Solar Concentrator Array with Refractive Linear Element Technology (SCARLET) design that was used on NASA's New Millennium Deep Space 1 mission. The highly successful asteroid/comet rendezvous mission (1998 to 2001) demonstrated the performance and long-term durability of the SCARLET/SLA solar array design and set the foundation for further improvements to optimize its performance.

  18. Intraocular lens implantation in microphthalmic patients.

    Science.gov (United States)

    Sinskey, R M; Amin, P; Stoppel, J

    1992-09-01

    Microphthalmos is a developmental disorder of the eye consisting of a smaller than normal eye. This disorder can present as an isolated condition or associated with other systemic alterations. It is not uncommon for patients with microphthalmos to have congenital cataracts along with other ocular and systemic abnormalities. This paper reports the experience with 11 microphthalmic eyes of seven patients who had primary or secondary intraocular lens (IOL) implantation over a six-year period from 1985 to 1991. In all cases the IOL had a 13.5 mm or 14.0 mm overall diameter and a 6.0 mm or 6.5 mm optic. It was difficult to obtain documentation of objective visual improvement in many of these cases because of the associated nystagmus. However, all patients reported subjective improvements. These results suggest that with proper technique and lens selection microphthalmic patients should be considered for IOL implantation with relative safety and success.

  19. Pulser for the Tevatron electron lens gun

    Energy Technology Data Exchange (ETDEWEB)

    Iouri Terechkine et al.

    2004-05-18

    To compensate for beam-beam interaction in Tevatron, an ''electron lens'' is considered to be an effective instrument. When a bunch of electrons with energy in the range (10-16) kV is overlapping with a bunch of antiprotons, the resulting focusing force for antiprotons can be adjusted by changing the electron beam current and by profiling its radial distribution. There exist several scenarios of how the system must function. According to one of them, an electron gun that supplies electrons must be fed by voltage pulses that follow with the frequency of antiproton bunches circulating in the Tevatron, which is about 2.5 MHz. To provide focusing tailored for each individual antiproton bunch, a modulator of the gun (pulser) must allow pulse-to-pulse voltage change. This report will cover main approaches to a design of a pulser for use with the gun of the Tevatron Electron Lens.

  20. Intraocular Lens Subluxation in Marfan Syndrome

    Science.gov (United States)

    Rodrigo, Bolaños-Jiménez; Paulina, López-Lizárraga E; Francesc, March de R; Eduardo, Telich-Tarriba J; Alejandro, Navas

    2014-01-01

    Purpose : Ectopia lentis (EL) is a major criteria for the diagnosis of Marfan syndrome, it may vary from an asymptomatic mild displacement to a significant subluxation that places the equator of the lens in the pupillary axis. The purpose of this work is to present the case of a patient with Marfan syndrome who received treatment for subluxation at our institution. Case Report : A 51-year-old female diagnosed with Marfan syndrome presented to the emergency department with bilateral eye redness, foreign body sensation and crusting around the eyes on awakening. She had the following history of cardiac and ophthalmologic complications, including: 1. Lens subluxation 2. High myopia 3. Aortic root dilation, 4. Mitral valve prolapse and 5. Tricuspid insufficiency. Conclusion : The ophthalmological management of Marfan patients is challenging and periodical follow-up is needed. Surgical versus conservative management is controversial, each case needs to be evaluated individually to analyze the risks and benefits of the procedures. PMID:25279020

  1. Understanding political market orientation

    DEFF Research Database (Denmark)

    Ormrod, Robert P.; Henneberg, Stephan C.

    influences of such behavior. The study includes structural equation modeling to investigate several propositions. While the results show that political parties need to focus on several different aspects of market-oriented behavior, especially using an internal and external orientation as cultural antecedents......This article develops a conceptual framework and measurement model of political market orientation that consists of attitudinal and behavioural constructs. The article reports on perceived relationships among different behavioral aspects of political market orientation and the attitudinal......, a more surprising result is the inconclusive effect of a voter orientation on market-oriented behaviours. The article discusses the findings in the context of the existing literature in political marketing and commercial market orientation....

  2. Orientalism and India

    Directory of Open Access Journals (Sweden)

    Jukka Jouhki

    2006-01-01

    Full Text Available In this article Orientalism, a special hegemonic discourse about "the Orient" by Europeans is discussed by focusing on how it is manifested in a "Western" view of India. Orientalism as a discourse about the Orient is a concept first coined by Edward Said in his book Orientalism (1978 and contains a long history of European way of relating to the Orient as a counterpart of European/Western culture. In this article Orientalist discourses about India by hegemonically Western (and particularly Anglo-Saxon sources are portrayed and the so-called Indo-Orientalist essentialism defining Indianness from the outside analyzed. Moreover, a Indo-Orientalism as an imported ideology to be used in Indian nationalist discourses to emphasize a dichotomy between India and "the West" is discussed.

  3. Sterilization potential of contact lens solutions

    OpenAIRE

    Dada Vijay; Mehta Manoj

    1988-01-01

    In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. ...

  4. Performance of a Be Refractive Lens

    International Nuclear Information System (INIS)

    Smither, R.K.; Khounsary, A.M.; Mancini, D.C.; Saleem, K. Abu

    2004-01-01

    The performance of a beryllium compound refractive lens (CRL) was tested in the energy range of 11.5 to 8.0 keV. The beryllium refractive lens consists of 50 aligned, 1-mm-diameter, hollow spheres in a solid block of beryllium, 30 mm x 20 mm x 55 mm. The minimum web between each hollow sphere was 0.10 mm. The measured focal length of the lens for x-rays close to the axis of the beam was 147.7 cm +/- 2.0 cm at 10 keV and 120.2 +/- 2.0 cm at 9.1 keV. These values agree well with the theoretical values of 146.6 cm and 121.4 cm, respectively. The diameter of the best focus obtained at 10 keV was 35 μm horizontal and 45 μm vertical. For the modified version of the lens used in the 9.1 keV experiment these values were 25 μm horizontal and 35 μm vertical. The x-ray beam cross section for the 10 keV and the 9.1 keV experiments were 0.50 mm x 0.50 mm and 0.30 mm x 0.30 mm, respectively. The enhancement of the flux (photons per sq. mm) was 50:1 at 10 keV and 80:1 in the 9.1 keV experiment

  5. THE BOSS EMISSION-LINE LENS SURVEY. IV. SMOOTH LENS MODELS FOR THE BELLS GALLERY SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Yiping [National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, Chaoyang District, Beijing 100012 (China); Bolton, Adam S.; Montero-Dorta, Antonio D.; Cornachione, Matthew A.; Zheng, Zheng; Brownstein, Joel R. [Department of Physics and Astronomy, University of Utah, 115 South 1400 East, Salt Lake City, UT 84112 (United States); Mao, Shude [Physics Department and Tsinghua Centre for Astrophysics, Tsinghua University, Beijing 100084 (China); Kochanek, Christopher S. [Department of Astronomy and Center for Cosmology and Astroparticle Physics, Ohio State University, Columbus, OH 43210 (United States); Pérez-Fournon, Ismael; Marques-Chaves, Rui [Instituto de Astrofísica de Canarias, C/Vía Láctea, s/n, E-38205 San Cristóbal de La Laguna, Tenerife (Spain); Oguri, Masamune [Research Center for the Early Universe, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Ménard, Brice, E-mail: yiping.shu@nao.cas.cn [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD 21218 (United States)

    2016-12-20

    We present Hubble Space Telescope F606W-band imaging observations of 21 galaxy-Ly α emitter lens candidates in the Baryon Oscillation Spectroscopic Survey Emission-Line Lens Survey (BELLS) for the GALaxy-Ly α EmitteR sYstems (BELLS GALLERY) survey. Seventeen systems are confirmed to be definite lenses with unambiguous evidence of multiple imaging. The lenses are primarily massive early-type galaxies (ETGs) at redshifts of approximately 0.55, while the lensed sources are Ly α emitters (LAEs) at redshifts from two to three. Although most of the lens systems are well fit by smooth lens models consisting of singular isothermal ellipsoids in an external shear field, a thorough exploration of dark substructures in the lens galaxies is required. The Einstein radii of the BELLS GALLERY lenses are, on average, 60% larger than those of the BELLS lenses because of the much higher source redshifts. This will allow for a detailed investigation of the radius evolution of the mass profile in ETGs. With the aid of the average ∼13× lensing magnification, the LAEs are frequently resolved into individual star-forming knots with a wide range of properties. They have characteristic sizes from less than 100 pc to several kiloparsecs, rest-frame far-UV apparent AB magnitudes from 29.6 to 24.2, and typical projected separations of 500 pc to 2 kpc.

  6. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  7. Two families of astrophysical diverging lens models

    Science.gov (United States)

    Er, Xinzhong; Rogers, Adam

    2018-03-01

    In the standard gravitational lensing scenario, rays from a background source are bent in the direction of a foreground lensing mass distribution. Diverging lens behaviour produces deflections in the opposite sense to gravitational lensing, and is also of astrophysical interest. In fact, diverging lensing due to compact distributions of plasma has been proposed as an explanation for the extreme scattering events that produce frequency-dependent dimming of extragalactic radio sources, and may also be related to the refractive radio wave phenomena observed to affect the flux density of pulsars. In this work we study the behaviour of two families of astrophysical diverging lenses in the geometric optics limit, the power law, and the exponential plasma lenses. Generally, the members of these model families show distinct behaviour in terms of image formation and magnification, however the inclusion of a finite core for certain power-law lenses can produce a caustic and critical curve morphology that is similar to the well-studied Gaussian plasma lens. Both model families can produce dual radial critical curves, a novel distinction from the tangential distortion usually produced by gravitational (converging) lenses. The deflection angle and magnification of a plasma lens vary with the observational frequency, producing wavelength-dependent magnifications that alter the amplitudes and the shape of the light curves. Thus, multiwavelength observations can be used to physically constrain the distribution of the electron density in such lenses.

  8. Dynamic metasurface lens based on MEMS technology

    Directory of Open Access Journals (Sweden)

    Tapashree Roy

    2018-02-01

    Full Text Available In the recent years, metasurfaces, being flat and lightweight, have been designed to replace bulky optical components with various functions. We demonstrate a monolithic Micro-Electro-Mechanical System (MEMS integrated with a metasurface-based flat lens that focuses light in the mid-infrared spectrum. A two-dimensional scanning MEMS platform controls the angle of the lens along two orthogonal axes by ±9°, thus enabling dynamic beam steering. The device could be used to compensate for off-axis incident light and thus correct for aberrations such as coma. We show that for low angular displacements, the integrated lens-on-MEMS system does not affect the mechanical performance of the MEMS actuators and preserves the focused beam profile as well as the measured full width at half maximum. We envision a new class of flat optical devices with active control provided by the combination of metasurfaces and MEMS for a wide range of applications, such as miniaturized MEMS-based microscope systems, LIDAR scanners, and projection systems.

  9. Adaptive Liquid Lens Actuated by Droplet Movement

    Directory of Open Access Journals (Sweden)

    Chao Liu

    2014-08-01

    Full Text Available In this paper we report an adaptive liquid lens actuated by droplet movement. Four rectangular PMMA (Polymethyl Methacrylate substrates are stacked to form the device structure. Two ITO (Indium Tin Oxide sheets stick on the bottom substrate. One PMMA sheet with a light hole is inserted in the middle of the device. A conductive droplet is placed on the substrate and touches the PMMA sheet to form a small closed reservoir. The reservoir is filled with another immiscible non-conductive liquid. The non-conductive liquid can form a smooth concave interface with the light hole. When the device is applied with voltage, the droplet stretches towards the reservoir. The volume of the reservoir reduces, changing the curvature of the interface. The device can thus achieve the function of an adaptive lens. Our experiments show that the focal length can be varied from −10 to −159 mm as the applied voltage changes from 0 to 65 V. The response time of the liquid lens is ~75 ms. The proposed device has potential applications in many fields such as information displays, imaging systems, and laser scanning systems.

  10. Thin wetting film lens-less imaging

    International Nuclear Information System (INIS)

    Allier, C.P.; Poher, V.; Coutard, J.G.; Hiernard, G.; Dinten, J.M.

    2011-01-01

    Lens-less imaging has recently attracted a lot of attention as a compact, easy-to-use method to image or detect biological objects like cells, but failed at detecting micron size objects like bacteria that often do not scatter enough light. In order to detect single bacterium, we have developed a method based on a thin wetting film that produces a micro-lens effect. Compared with previously reported results, a large improvement in signal to noise ratio is obtained due to the presence of a micro-lens on top of each bacterium. In these conditions, standard CMOS sensors are able to detect single bacterium, e.g. E. coli, Bacillus subtilis and Bacillus thuringiensis, with a large signal to noise ratio. This paper presents our sensor optimization to enhance the SNR; improve the detection of sub-micron objects; and increase the imaging FOV, from 4.3 mm 2 to 12 mm 2 to 24 mm 2 , which allows the detection of bacteria contained in 0.5 μl to 4 μl to 10 μl, respectively. (authors)

  11. Laboratory Demonstration of Axicon-Lens Coronagraph

    Science.gov (United States)

    Choi, Jaeho; Jea, Geonho

    2018-01-01

    The results of laboratory based experiments of the proposed coronagraph using axicon-lenses that is conjunction with a method of noninterferometric quantitative phase imaging for direct imaging of exoplanets is will present. The light source is passing through tiny holes drilled on the thin metal plate is used as the simulated stellar and its companions. Those diffracted light at the edge of the holes bears a similarity to the light from the bright stellar. Those images are evaginated about the optical axis after the maximum focal length of the first axicon lens. Then the evaginated images of have cut off using the motorized iris which means the suppressed the central stellar light preferentially. Various length between the holes which represent the angular distance are examined. The laboratory experimental results are shown that the axicon-lens coronagraph has feature of ability to achieve the smaller IWA than l/D and high-contrast direct imaging. The laboratory based axicon-lens coronagraph imaging support the symbolic computation results which has potential in direct imaging for finding exoplanet and various astrophysical activities. The setup of the coronagraph is simple to build and is durable to operate. Moreover it can be transported the planets images to a broadband spectrometric instrument that able to investigate the constituent of the planetary system.

  12. Metasurface axicon lens design at visible wavelengths

    Science.gov (United States)

    Alyammahi, Saleimah; Zhan, Qiwen

    2017-08-01

    The emerging field of metasurfaces is promising to realize novel optical devices with miniaturized flat format and added functionalities. Metasurfaces have been demonstrated to exhibit full control of amplitude, phase and polarization of electromagnetic waves. Using the metasurface, the wavefront of light can be manipulated permitting new functionalities such as focusing and steering of the beams and imaging. One optical component which can be designed using metasurfaces is the axicon. Axicons are conical lenses used to convert Gaussian beams into nondiffraction Bessel beams. These unique devices are utilized in different applications ranging from optical trapping and manipulation, medical imaging, and surgery. In this work, we study axicon lens design comprising of planar metasurfaces which generate non-diffracting Bessel beams at visible wavelengths. Dielectric metasurfaces have been used to achieve high efficiency and low optical loss. We measured the spot size of the resulted beams at different planes to demonstrate the non-diffraction properties of the resulted beams. We also investigated how the spot size is influenced by the axicon aperture. Furthermore, we examined the achromatic properties of the designed axicon. Comparing with the conventional lens, the metasurface axicon lens design enables the creation of flat optical device with wide range of depth of focus along its optical axis.

  13. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla

    2015-01-01

    Radiation Dose to the Eye Lens: Does Positioning Really Matter? C. Baun1, K. Falch1, K.D. Nielsen2, S. Shanmuganathan1, O. Gerke1, P.F. Høilund-Carlsen1 1Department of Nuclear Medicine, Odense University Hospital, Odense C, Denmark. 2University College Lillebaelt, Odense, Denmark. Aim: The scan...... field in oncology patients undergoing eyes-to-thighs PET/CT must always include the base of the scull according to department guidelines. The eye lens is sensitive to radiation exposure and if possible it should be avoided to scan the eye. If the patient’s head is kipped backwards during the scan one...... might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull...

  14. Dynamic metasurface lens based on MEMS technology

    Science.gov (United States)

    Roy, Tapashree; Zhang, Shuyan; Jung, Il Woong; Troccoli, Mariano; Capasso, Federico; Lopez, Daniel

    2018-02-01

    In the recent years, metasurfaces, being flat and lightweight, have been designed to replace bulky optical components with various functions. We demonstrate a monolithic Micro-Electro-Mechanical System (MEMS) integrated with a metasurface-based flat lens that focuses light in the mid-infrared spectrum. A two-dimensional scanning MEMS platform controls the angle of the lens along two orthogonal axes by ±9°, thus enabling dynamic beam steering. The device could be used to compensate for off-axis incident light and thus correct for aberrations such as coma. We show that for low angular displacements, the integrated lens-on-MEMS system does not affect the mechanical performance of the MEMS actuators and preserves the focused beam profile as well as the measured full width at half maximum. We envision a new class of flat optical devices with active control provided by the combination of metasurfaces and MEMS for a wide range of applications, such as miniaturized MEMS-based microscope systems, LIDAR scanners, and projection systems.

  15. Radiation dose to the lens and cataract formation

    International Nuclear Information System (INIS)

    Henk, J.M.; Whitelocke, R.A.F.; Warrington, A.P.; Bessell, E.M.

    1993-01-01

    The purpose of this work was to determine the radiation tolerance of the lens of the eye and the incidence of radiation-induced lens changes in patients treated by fractionated supervoltage radiation therapy for orbital tumors. Forty patients treated for orbital lymphoma and pseudotumor with tumor doses of 20--40 Gy were studied. The lens was partly shielded using lead cylinders in most cases. The dose to the germinative zone of the lens was estimated by measurements in a tissue equivalent phantom using both film densitometry and thermoluminescent dosimetry. Opthalmological examination was performed at 6 monthly intervals after treatment. The lead shield was found to reduce the dose to the germinative zone of the lens to between 36--50% of the tumor dose for Cobalt beam therapy, and to between 11--18% for 5 MeV x-rays. Consequently, the lens doses were in the range 4.5--30 Gy in 10--20 fractions. Lens opacities first appeared from between 3 and 9 years after irradiation. Impairment of visual acuity ensued in 74% of the patients who developed lens opacities. The incidence of lens changes was strongly dose-related. None was seen after doses of 5 Gy or lower, whereas doses of 16.5 Gy or higher were all followed by lens opacities which impaired visual acuity. The largest number of patients received a maximum lens dose of 15 Gy; in this group the actuarial incidence of lens opacities at 8 years was 57% with visual impairment in 38%. The adult lens can tolerate a total dose of 5 Gy during a fractionated course of supervoltage radiation therapy without showing any changes. Doses of 16.5 Gy or higher will almost invariably lead to visual impairment. The dose which causes a 50% probability of visual impairment is approximately 15 Gy. 10 refs., 4 figs., 1 tab

  16. Motorized injector-assisted intrascleral intraocular lens fixation.

    Science.gov (United States)

    Hung, Jia-Horung; Wang, Shih-Hao; Teng, Yu-Ti; Hsu, Sheng-Min

    2017-03-01

    For eyes with deficient capsular support, intraocular lens (IOL) implantation has long been a technical challenge. Recently, intrascleral fixation of the haptics of a three-piece posterior chamber IOL has become a popular option. In this procedure, externalization of the leading haptic during IOL injection is a stressful step. We present a modified technique to improve the ease and safety of this step. Our modified technique involves IOL injection with a motorized injector with several important modifications described here. With these modifications, a surgeon can easily maintain the correct orientation of the IOL in a well-controlled manner during IOL injection. The records of 13 patients who underwent this technique were retrospectively evaluated. Corrected-distance visual acuity improved significantly after surgery (pIOL decentration, or vitreous hemorrhage was noted during the follow-up period. In conclusion, the motorized injector-assisted intrascleral IOL fixation technique is a safe and effective alternative to the conventional procedure. This technique makes the process of leading haptic externalization easier and more controllable. Copyright © 2017. Published by Elsevier Taiwan.

  17. Motorized injector-assisted intrascleral intraocular lens fixation

    Directory of Open Access Journals (Sweden)

    Jia-Horung Hung

    2017-03-01

    Full Text Available For eyes with deficient capsular support, intraocular lens (IOL implantation has long been a technical challenge. Recently, intrascleral fixation of the haptics of a three-piece posterior chamber IOL has become a popular option. In this procedure, externalization of the leading haptic during IOL injection is a stressful step. We present a modified technique to improve the ease and safety of this step. Our modified technique involves IOL injection with a motorized injector with several important modifications described here. With these modifications, a surgeon can easily maintain the correct orientation of the IOL in a well-controlled manner during IOL injection. The records of 13 patients who underwent this technique were retrospectively evaluated. Corrected-distance visual acuity improved significantly after surgery (p<0.05. No postoperative retinal detachment, endophthalmitis, IOL decentration, or vitreous hemorrhage was noted during the follow-up period. In conclusion, the motorized injector-assisted intrascleral IOL fixation technique is a safe and effective alternative to the conventional procedure. This technique makes the process of leading haptic externalization easier and more controllable.

  18. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  19. A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system

    Science.gov (United States)

    Dou, Yanxin; Jamieson, David N.; Liu, Jianli; Li, Liyi

    2018-03-01

    This paper describes the design of a new probe forming lens system consisting of a high excitation magnetic quadrupole lens quadruplet that incorporates a single magnetic octupole lens. This system achieves both a high demagnification and a low spherical aberration compared to conventional high excitation systems and is intended for deployment for the Harbin 300 MeV proton microprobe for applications in space science and ion beam therapy. This relative simplicity of the ion optical design to include a single octupole lens minimizes the risks associated with the constructional and operational precision usually needed for the probe forming lens system and this system could also be deployed in microprobe systems that operate with less magnetically rigid ions. The design of the new system is validated with reference to two independent ion optical computer codes.

  20. The neutron silicon lens. An update of the thermal neutron lens results

    International Nuclear Information System (INIS)

    Johnson, M.W.; Daymond, M.R.

    2001-01-01

    This paper introduces the concept of the Neutron Silicon Lens (NSL) and provides and update on the experimental results achieved to date. The NSL design is a cylindrical neutron lens based on the use of multiple neutron mirrors supported and separated by silicon wafers. Such lenses would have many applications in both the primary and scattered beams on neutron instruments, and would lead to immediate improvements where the sample to be illuminated is small, as in high pressure or engineering strain scanning instruments. (author)

  1. Forensic Analysis of a Contact Lens in a Murder Case.

    Science.gov (United States)

    Zwerling, Charles S

    2016-03-01

    Contact lenses have had rare relevance in trials and/or investigations. After 5 years of burial, orbital remnants were retrieved from an exhumed body and subsequently identified as a key piece of material evidence in a murder trial. The exhumed case materials were evaluated under laboratory conditions and were determined to be contact lens remnants. Contact lens fracture and burial simulation studies were performed to provide additional corroboration of the physical findings of the exhumed contact lens remnants. This material evidence was instrumental in providing factual proof refuting the defendant's testimony in the murder trial. A brief history of contact lens composition and use is provided for understanding the methods and observational results. This forensic case study represents the first published documentation of a contact lens from an exhumed body being used in a murder investigation and establishes an operational procedure for future forensic contact lens examinations. © 2016 American Academy of Forensic Sciences.

  2. Measuring the light scattering and orientation of a spheroidal particle using in-line holography.

    Science.gov (United States)

    Seo, Kyung Won; Byeon, Hyeok Jun; Lee, Sang Joon

    2014-07-01

    The light scattering properties of a horizontally and vertically oriented spheroidal particle under laser illumination are experimentally investigated using digital in-line holography. The reconstructed wave field shows the bright singular points as a result of the condensed beam formed by a transparent spheroidal particle acting as a lens. The in-plane (θ) and out-of-plane (ϕ) rotating angles of an arbitrarily oriented spheroidal particle are measured by using these scattering properties. As a feasibility test, the 3D orientation of a transparent spheroidal particle suspended in a microscale pipe flow is successfully reconstructed by adapting the proposed method.

  3. Lens regeneration in mice under the influence of vitamin A

    Indian Academy of Sciences (India)

    The effect of vitamin A has been studied on lens regeneration in young (7 days old) as well as adult mice. A longitudinal slit was made under local anesthesia in the cornea over the lens. The lens was extracted intact through the incision. Intraperitonial injection of vitamin A (0.05 ml of 30 IU/ml in young and 0.05 ml of 50 ...

  4. Subcontact Lens Bubble Formation under Low Atmospheric Pressure Conditions.

    Science.gov (United States)

    1986-08-01

    of subcontact lens bubble formation under scleral lenses at altitudes greater than 18,000 ft. Later, after many advances in contact lens fitting and...Reported here are the results of contact lens bubble studies with soft hydrophilic nd rigid gas-permeable lenses . Testing was accomplished in simulated...ccurred at altitudes greater than 20,000 ft. For soft contact lenses , bubble formation was etected in 22 of 92 eyes tested, and occurred at altitudes

  5. Analysis of phakic before intraocular lens implantation for fundus examination

    OpenAIRE

    Juan Chen; Zhong-Ping Chen; Rui-Ling Zhu

    2014-01-01

    AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL). To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examina...

  6. Haemophilus influenzae corneal ulcer in a therapeutic contact lens wearer.

    OpenAIRE

    Armstrong, J. R.; Cohen, K. L.; McCarthy, L. R.

    1984-01-01

    Haemophilus influenzae is an unusual corneal pathogen and an unusual cause of corneal ulcers in Western society. In previous reports corneal complications from H. influenzae have been secondary to a conjunctivitis. The first case of a primary H. influenzae corneal ulcer as a complication of therapeutic contact lens wear is presented. Since other uncommon bacteria have been reported as causes of contact lens related corneal ulcers, the bacteriology of contact lens related corneal ulcers is rev...

  7. Entrepreneurial Orientation and Internationalisation

    DEFF Research Database (Denmark)

    Decker, Arnim; Rollnik-Sadowska, Ewa; Servais, Per

    orientation as an attitude held by principals we investigate how entrepreneurial orientation affected the behaviour of these firms, specifically in terms of their internationalisation. Despite the fact that all firms have identical roots we find that entrepreneurial orientation held by their principals affect......Entrepreneurial orientation is a multidimensional construct that determines the strategic posture of a firm. In this study we investigate a sample of six manufacturing firms which are located both in a remote area and in a transition economy. Through interpreting the construct of entrepreneurial...

  8. Disposable contact lenses vs. contact lens maintenance for extended wear.

    Science.gov (United States)

    Josephson, J E; Caffery, B E; Campbell, I; Slomovic, A R

    1990-01-01

    We compared a disposable extended wear contact lens modality with conventional extended wear over a 6-week period. To do so, we refit 31 patients who had successfully worn conventional extended wear contact lenses for more than 1 year. One eye was fit with the AcuvueR disposable contact lens, and a new extended wear lens of the type the patient had been wearing was placed on the other eye. At weekly intervals the disposable lens was discarded and a new disposable lens inserted. At the same time, the conventional lens on the fellow eye was cleaned, disinfected, and reinserted. After 6 weeks the ocular response, subjective impressions, and condition of the lenses in the two eyes were compared. Both lenses were then cultured. Three subjects had to discontinue disposable lens wear because of adverse reactions to trapped cellular debris and corneal microcysts. Although the results were not statistically significant, the Acuvue lens appeared to perform better than or equal to the conventional lens in biomicroscopic observation, visual acuity measurement, and subjective patient preference. Eighty-seven percent of patients preferred to continue with the disposable system. There were no differences found in the type or degree of microbial contamination of the lenses.

  9. Further studies of contact lens motion during blinking.

    Science.gov (United States)

    Conway, H D; Knoll, H A

    1986-10-01

    Contact lens motion is felt to be of increasing importance in connection with debris elimination, particularly in extended wear lenses. Thus an improved analysis is made of a simple model for investigating the initial motion of a hard contact lens over the eye during blinking. It is shown that the assumption of constant tear film thickness is a reasonable one. This greatly simplifies the analysis. Various vertical force vs. time variations are considered and lens velocity/time graphs and maximum lens displacement calculated. These are in good agreement with the results of experiment.

  10. Geometry-invariant gradient refractive index lens: analytical ray tracing.

    Science.gov (United States)

    Bahrami, Mehdi; Goncharov, Alexander V

    2012-05-01

    A new class of gradient refractive index (GRIN) lens is introduced and analyzed. The interior iso-indicial contours mimic the external shape of the lens, which leads to an invariant geometry of the GRIN structure. The lens model employs a conventional surface representation using a coincoid of revolution with a higher-order aspheric term. This model has a unique feature, namely, it allows analytical paraxial ray tracing. The height and the angle of an arbitrary incident ray can be found inside the lens in a closed-form expression, which is used to calculate the main optical characteristics of the lens, including the optical power and third-order monochromatic aberration coefficients. Moreover, due to strong coupling of the external surface shape to the GRIN structure, the proposed GRIN lens is well suited for studying accommodation mechanism in the eye. To show the power of the model, several examples are given emphasizing the usefulness of the analytical solution. The presented geometry-invariant GRIN lens can be used for modeling and reconstructing the crystalline lens of the human eye and other types of eyes featuring a GRIN lens.

  11. Particle swarm optimization applied to automatic lens design

    Science.gov (United States)

    Qin, Hua

    2011-06-01

    This paper describes a novel application of Particle Swarm Optimization (PSO) technique to lens design. A mathematical model is constructed, and merit functions in an optical system are employed as fitness functions, which combined radiuses of curvature, thicknesses among lens surfaces and refractive indices regarding an optical system. By using this function, the aberration correction is carried out. A design example using PSO is given. Results show that PSO as optical design tools is practical and powerful, and this method is no longer dependent on the lens initial structure and can arbitrarily create search ranges of structural parameters of a lens system, which is an important step towards automatic design with artificial intelligence.

  12. [Phacoemulsification of subluxated lens with capsular tension ring implantation].

    Science.gov (United States)

    Dorecka, Mariola; Rokicki, Wojciech; Nita, Malgorzata; Krysik, Katarzyna; Nita, Ewa; Sikorska, Aleksandra; Romaniuk, Wanda

    2007-01-01

    To evaluate long term results of phacoemulsification with PC IOL and capsular tension ring (CTR) implantation in lens subluxation. The study comprised of 134 patients--146 eyes with subluxated lens. In all cases phacoemulsification with PC IOL and CTR implantation was performed. No intaroperative complications has occured. Postoperative complications included: inflammation in the anterior chamber in 3 eyes (2.1%), retinal detachment in 2 eyes (1.4%). In all cases there was no PC IOL decentration. (1) CTR facilitates phacoemulsification with PC IOL implantation in lens subluxation. (2) Phacoemulsification of subluxated lens with PC IOL and CTR implantation seems to be safe and effective procedure.

  13. Acoustic Luneburg lens using orifice-type metamaterial unit cells

    Science.gov (United States)

    Park, Choon Mahn; Lee, Sang Hun

    2018-02-01

    A two-dimensional acoustic Luneburg lens that can be easily expanded into a three-dimensional sphere is fabricated. The required spatial distribution of the refractive index for this Luneburg lens is realized using the characteristics of orifice-type metamaterial unit cells. Typical characteristics of the resulting acoustic Luneburg lens, such as its aberration-free performance and capability for antipodal focusing of the lens for the incident plane waves, are investigated through experiments and simulations with the attenuation loss at frequencies that satisfy the homogeneous medium condition of the metamaterial. With the designed metamaterial, we achieved the minimum spot that lies within the classical diffraction limit at the focal point.

  14. Optimization of Lens Adjustment in Semiconductor Lithography Equipment Using Quadratically Constrained and Second-Order Cone Programming

    Science.gov (United States)

    Shinano, Yuji; Yoshihara, Toshiyuki; Miyashiro, Ryuhei; Fukagawa, Youzou

    The present paper considers optimization of lens adjustment in semiconductor lithography equipment. For improving productivity, the laser irradiation power of recent semiconductor lithography equipment has been boosted, which causes significant aberration due to heating during exposure. The aberration of the equipment must be measured or estimated in order to adjust the positions and orientations of the lenses. Since this adjustment is performed sequentially during exposure, the optimization problem to obtain optimal lens adjustment should be solved within a time as short as 100 ms. Although the problem of calculating the optimal lens adjustment can be naturally formulated as a convex minimization problem, in such a formulation the objective function is convex but includes several nondifferentiable points. Hence, optimization methods based on derivatives cannot be applied. Other approaches using derivative-free optimization or meta-heuristic methods cannot guarantee that the obtained solutions are truly optimal. Therefore, we formulate the optimization problem as quadratically constrained and second-order cone programming problems, which can be handled by solvers using an interior point method. Using the proposed formulations, computational experiments demonstrate that the optimal lens adjustment is obtained in a practical computational time, which is much less than 100 ms.

  15. Spontaneous dislocation of lens bag with acrylic lens after uneventful cataract surgery ? unusual complication of cataract surgery

    OpenAIRE

    Shah, Mehul A.; Shah, Shreya M.; Mehta, Ruchir; Shah, Prerna

    2015-01-01

    Introduction: Spontaneous dislocation of intraocular lens with bag is rare.Methods: We report a case of a 56-year-old male who presented with spontaneous anterior dislocation of an in-the-bag intraocular lens 3 years after manual small incision cataract surgery. He had undergone manual small incision cataract surgery with foldable acrylic intraocular lens implantation, and 18 months after cataract surgery ND: YAG capsulotomy with uneventful post capsulotomy follow-up. 17 months after capsul...

  16. LENS - the Low-Energy Neutrino Spectrometer

    International Nuclear Information System (INIS)

    Hahn, Richard L.

    2004-01-01

    Despite the recent successes of SNO and KamLAND, the only detectors sensitive to <1 MeV-neutrinos have been the radiochemical chlorine and gallium solar neutrino experiments. LENS is being developed to measure in real time the charge-current fluxes and energy spectra of the lowest energy solar neutrinos, from the pp and 7Be branches (91% and 7% of solar neutrinos). The detector medium will be a metal-loaded liquid scintillator (M-LS), with indium as the metal, which serves as the target for neutrino capture in the LS. 115In has 95.71% natural abundance and a 114.2-keV neutrino-capture Q-value. Neutrino capture in 115In produces a β particle and preferentially feeds an excited state of 115Sn that de-excites by delayed emission of two γ rays. This triple-coincidence 'tag' in time and space in principle is a very powerful tool to discriminate neutrino-capture events from backgrounds. The International LENS R and D Collaboration is working to develop an In-LS neutrino detector, with special properties, such as high indium content, high light yield, high optical transparency, long-term chemical stability, and good signal-to-background ratio. Success in preparing the In-LS has been achieved via the synthesis of In-carboxylates that are soluble in pseudocumene LS (note that these methods may also be applicable to the preparation of Gd-LS for reactor antineutrino experiments). Testing of some prototype LENS In-LS detector modules has begun recently at the Gran Sasso Laboratory

  17. [Corneal protection in contact lens users].

    Science.gov (United States)

    Egorova, G B; Mitichkina, T S; Shamsudinova, A R

    2014-01-01

    To evaluate the efficacy of corneoprotective agents (Corneregel and Solcoseryl) in contact lens users. A total of 66 long-term contact lens wearers with dry eye symptoms and varying degrees of corneal epitheliopathy were monitored. All patients used artificial tears, which, however, were not effective enough to suppress manifestations of corneal epitheliopathy and to release the associated discomfort. The therapy was supplemented with Corneregel. The following examination methods were applied: biomicroscopy with fluorescent staining, Norn test, Schirmer's test, advanced tearscopy with digital image analysis of the precorneal tear film lipid layer, corneal confocal microscopy. In all cases the assessment was performed prior to starting Corneregel and repeated in 7 days, 14 days and 1 month. Complete corneal re-epithelization and restoration of the most superficial layer of the epithelium were achieved within 7-14 days. In case of severe initial epitheliopathy the effect of Corneregel was not sufficient and epithelium defects remained. These patients additionally received Solcoseryl Eye Gel. After the treatment course the condition of corneal epithelium ameliorated and contact lens wearing comfort increased. A longer precorneal tear film break-up time indicated an increase of tear film stability. The total tear production did not change significantly. The moistening effect of Corneregel and low-viscosity artificial tears together with intensive regeneration of corneal epithelium enables structural recovery of the epithelial membrane and considerable improvement of the anterior corneal stroma. At the first stage of corneoprotective treatment it is appropriate to use preservative-free artificial tears of low and high viscosity. If the effect of tear substitutive therapy is unsatisfactory it is recommended to prescribe Corneregel and Solcoseryl. The regimen is to be adjusted individually.

  18. Lentil (Lens culinaris) Lipid Transfer Protein Len c 3: A Novel Legume Allergen

    NARCIS (Netherlands)

    Akkerdaas, J.; Finkina, E. I.; Balandin, S. V.; Santos Magadán, S.; Knulst, A.; Fernandez-Rivas, M.; Asero, R.; van Ree, R.; Ovchinnikova, T. V.

    2012-01-01

    Background: Lentils are increasingly consumed in many parts of the world. Two allergens, Len c 1 and 2, have been reported previously. Recently, peanut and green bean lipid transfer proteins (LTPs) have been identified as the first two members of an important group of allergens that might be

  19. Abnormal lens morphogenesis and ectopic lens formation in the absence of beta-catenin function

    Czech Academy of Sciences Publication Activity Database

    Krešlová, Jana; Machoň, Ondřej; Růžičková, Jana; Láchová, Jitka; Wawrousek, E.F.; Kemler, R.; Krauss, S.; Piatigorsky, J.; Kozmik, Zbyněk

    2007-01-01

    Roč. 45, č. 4 (2007), s. 157-168 ISSN 1526-954X R&D Projects: GA ČR GA204/04/1358 Institutional research plan: CEZ:AV0Z50520514 Keywords : Wnt * beta-catenin * gene * lens Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.516, year: 2007

  20. Golden Gravitational Lensing Systems from the Sloan Lens ACS Survey. I. SDSS J1538+5817: One Lens for Two Sources

    Science.gov (United States)

    Grillo, C.; Eichner, T.; Seitz, S.; Bender, R.; Lombardi, M.; Gobat, R.; Bauer, A.

    2010-02-01

    We present a gravitational lensing and photometric study of the exceptional strong lensing system SDSS J1538+5817, identified by the Sloan Lens Advanced Camera for Survey. The lens is a luminous elliptical galaxy at redshift zl = 0.143. Using Hubble Space Telescope public images obtained with two different filters, the presence of two background sources lensed, respectively, into an Einstein ring and a double system is ascertained. Our new spectroscopic observations, performed at the Nordic Optical Telescope, reveal unequivocally that the two sources are located at the same redshift zs = 0.531. We investigate the total (luminous and dark) mass distribution of the lens between 1 and 4 kpc from the galaxy center by means of parametric and non-parametric lensing codes that describe the multiple images as point-like objects. Bootstrapping and Bayesian analyses are performed to determine the uncertainties on the quantities relevant to the lens mass characterization. Several disparate lensing models provide results that are consistent, given the errors, with those obtained from the best-fit model of the lens mass distribution in terms of a singular power-law ellipsoid model. In particular, the lensing models agree on: (1) reproducing accurately the observed positions of the images; (2) predicting a nearly axisymmetric total mass distribution, centered and oriented as the light distribution; (3) measuring a value of 8.11+0.27 -0.59 × 1010 M sun for the total mass projected within the Einstein radius of 2.5 kpc; and (4) estimating a total mass density profile slightly steeper than an isothermal one (ρ (r) ∝ r^{-2.33^{+0.43}_{-0.20}}). A fit of the Sloan Digital Sky Survey multicolor photometry with composite stellar population models provides a value of 20+1 -4 × 1010 M sun for the total mass of the galaxy in the form of stars and of 0.9+0.1 -0.2 for the fraction of projected luminous over total mass enclosed inside the Einstein radius. By combining lensing (total

  1. Magnetic system of the Tevatron electron lens

    International Nuclear Information System (INIS)

    Bogdanov, I.; Kozub, S.; Pleskach, V.; Sytnik, V.; Tkachenko, L.; Zintchenko, S.; Zubko, V.; Kuznetsov, G.; Sery, A.; Shiltsev, V.

    2000-01-01

    The Tevatron Electron Lens (TEL) system consisting of seven SC and four conventional magnets has been developed and fabricated in IHEP for increase of luminosity in Tevatron. The SC cable tension and preload of SC coils are calculated. The chosen cable design and cooling of the SC magnets ensure sufficient temperature margin for operating of SC magnets and their safety during quench. The system of conventional and SC solenoids create necessary trajectory of magnetic field lines for the TEL electron beam motion. SC dipoles and warm correctors permit to carry out correction of the electron beam motion [ru

  2. Septic lens implantation syndrome in a cat.

    Science.gov (United States)

    Dalesandro, Nicole; Stiles, Jean; Miller, Margaret

    2011-09-01

    A 13-year-old female spayed domestic shorthair cat was presented initially for a change in the appearance of the left eye. On initial examination, a small penetrating wound was suspected as the cause for a corneal scar, an anterior cortical incipient cataract and mild iritis. The cat was not re-presented until 1 year later at which time ocular pain was marked. Severe anterior uveitis and glaucoma were diagnosed and the eye enucleated. Histopathology documented intralenticular coccoid bacteria and septic lens implantation syndrome. © 2011 American College of Veterinary Ophthalmologists.

  3. [Contact lens-associated Paecilomyces lilacinus keratitis].

    Science.gov (United States)

    Mihailovic, N; Alnawaiseh, M; Zumhagen, L; Eter, N

    2017-01-01

    We present the case of a 23-year-old otherwise healthy female patient with contact lens-associated Paecilomyces lilacinus keratitis. The clinical findings stabilized after initial local antimycotic and antibacterial treatment; however, in the further course of local therapy an extensive relapse occurred which required treatment by perforating keratoplasty à chaud due to a penetrating corneal ulcer. The patient responded well to subsequent treatment with systemic and local antimycotic medication. After a few months HLA-matched keratoplasty was performed. During the follow-up time of 14 months there were no signs of recurrence of the infection.

  4. Scleral lens for keratoconus: technology update

    OpenAIRE

    Rathi, Varsha; Taneja,Mukesh; Mandathara,Preeji; Sangwan,Virender; Dumpati,Srikanth

    2015-01-01

    Varsha M Rathi,1 Preeji S Mandathara,2 Mukesh Taneja,1 Srikanth Dumpati,1 Virender S Sangwan1 1L V Prasad Eye Institute, Hyderabad, India; 2School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia Abstract: Scleral lenses are large diameter lenses which rest over the sclera, unlike the conventional contact lenses which rest on the cornea. These lenses are fitted to not touch the cornea and there is a space created between the cornea and the lens. Th...

  5. Scientific performance assessments through a gender lens

    DEFF Research Database (Denmark)

    Nielsen, Mathias Wullum

    2018-01-01

    The focus on excellence and quality assurance in the academy has spawned a signifi cant increase in the use of bibliometric measures in performance assessments of individual researchers. This article investigates the organizational consequences of this development through a gender lens. Based....... They adhere to the prevailing ethos of the academic meritocracy by standardizing the criteria for organizational advancement and ensuring transparency and accountability in the selection process. While bibliometric tools in this sense may lead to the recruitment of scientists with a strong CV and track record...

  6. Polarization response of RHIC electron lens lattices

    Directory of Open Access Journals (Sweden)

    V. H. Ranjbar

    2016-10-01

    Full Text Available Depolarization response for a system of two orthogonal snakes at irrational tunes is studied in depth using lattice independent spin integration. In particular we consider the effect of overlapping spin resonances in this system, to understand the impact of phase, tune, relative location and threshold strengths of the spin resonances. These results are benchmarked and compared to two dimensional direct tracking results for the RHIC e-lens lattice and the standard lattice. Finally we consider the effect of longitudinal motion via chromatic scans using direct six dimensional lattice tracking.

  7. Aspect-Oriented Programming

    NARCIS (Netherlands)

    Bergmans, Lodewijk; Videira Lopes, Cristina; Moreira, Ana; Demeyer, Serge

    1999-01-01

    Aspect-oriented programming is a promising idea that can improve the quality of software by reduce the problem of code tangling and improving the separation of concerns. At ECOOP'97, the first AOP workshop brought together a number of researchers interested in aspect-orientation. At ECOOP'98, during

  8. Staying oriented while driving

    NARCIS (Netherlands)

    Ridder, S.N. de

    2002-01-01

    Do elderly drivers have more trouble finding their way and staying spatially oriented than younger drivers do? If spatial orientation is more difficult for elderly drivers it could distract attention from vehicle control resulting in a higher accident rate for elderly drivers. Moreover, it could

  9. Edward Said and "Orientalism"

    Science.gov (United States)

    Chronicle of Higher Education, 2007

    2007-01-01

    In the nearly 30 years since Edward Said published the hugely influential Orientalism, his indictment of racism and imperialism in Western scholarship on the Orient has had its share of plaudits and condemnations. Now Robert Irwin, the Middle East editor of The Times Literary Supplement, has reignited the controversy with his broadside against the…

  10. Towards a new orientation

    DEFF Research Database (Denmark)

    Jensen, Janet F; Overgaard, Dorthe; Bestle, Morten H

    2017-01-01

    narrative of recovery was 'toward a trajectory of new orientation'. This narrative contained the chronological narratives of being 'at death's door', 'still not out of the woods' and 'on the road to recovery'. The road to recovery was described as downhill, steady-state or progressive. New orientation...

  11. Wildlife value orientations

    DEFF Research Database (Denmark)

    Gamborg, Christian; Jensen, Frank Søndergaard

    2016-01-01

    This article examined value orientations toward wildlife among the adult general Danish public in relation to age, sex, past and present residence, education, and income, using a U.S. survey instrument on Wildlife Value Orientations (WVO). The study used an Internet-based questionnaire sent...

  12. Competitiveness through strategic orientation

    Directory of Open Access Journals (Sweden)

    Diego Monferrer

    2012-12-01

    Full Text Available The aim of this paper is to further the study of the factors that influence the international competitive position of international new ventures and, consequently, their international performance. Specifically, we analyze the role of entrepreneurial and market orientations in the international competitive position of such firms. Data were collected at Spanish and Belgian international new ventures. The structural equations model approach was used to test our hypotheses. Both the Spanish and the Belgian sample revealed a positive and significant relationship between entrepreneurial orientation and market orientation. Furthermore, both orientations have a positive and significant effect on the international competitive position of such firms. Finally, any firm’s international competitive position is positively and significantly related to its international performance. The study therefore appears to indicate that, when it comes to international new ventures, the conjunction of these two orientations is a key factor to attaining a superior competitive position and a positive performance in international markets.

  13. Candidate gravitational microlensing events for future direct lens imaging

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, C. B.; Gould, A.; Gaudi, B. S. [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Park, H.; Han, C. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Sumi, T.; Koshimoto, N. [Department of Earth and Space Science, Osaka University, Osaka 560-0043 (Japan); Udalski, A. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Tsapras, Y. [Las Cumbres Observatory Global Telescope Network, 6740 Cortona Drive, Suite 102, Goleta, CA 93117 (United States); Bozza, V. [Department of Physics, University of Salerno, I-84084 Fisciano (Italy); Abe, F.; Fukunaga, D.; Itow, Y.; Masuda, K. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Bennett, D. P. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556-5670 (United States); Bond, I. A.; Ling, C. H. [Institute of Information and Mathematical Sciences, Massey University, Private Bag 102-904, North Shore Mail Centre, Auckland 0745 (New Zealand); Botzler, C. S.; Freeman, M. [Department of Physics, University of Auckland, Private Bag 92-019, Auckland 1001 (New Zealand); Fukui, A. [School of Chemical and Physical Sciences, Victoria University, Wellington 6140 (New Zealand); Collaboration: MOA Collaboration; OGLE Collaboration; μFUN Collaboration; RoboNet Collaboration; and others

    2014-10-10

    The mass of the lenses giving rise to Galactic microlensing events can be constrained by measuring the relative lens-source proper motion and lens flux. The flux of the lens can be separated from that of the source, companions to the source, and unrelated nearby stars with high-resolution images taken when the lens and source are spatially resolved. For typical ground-based adaptive optics (AO) or space-based observations, this requires either inordinately long time baselines or high relative proper motions. We provide a list of microlensing events toward the Galactic bulge with high relative lens-source proper motion that are therefore good candidates for constraining the lens mass with future high-resolution imaging. We investigate all events from 2004 to 2013 that display detectable finite-source effects, a feature that allows us to measure the proper motion. In total, we present 20 events with μ ≳ 8 mas yr{sup –1}. Of these, 14 were culled from previous analyses while 6 are new, including OGLE-2004-BLG-368, MOA-2005-BLG-36, OGLE-2012-BLG-0211, OGLE-2012-BLG-0456, MOA-2012-BLG-532, and MOA-2013-BLG-029. In ≲12 yr from the time of each event the lens and source of each event will be sufficiently separated for ground-based telescopes with AO systems or space telescopes to resolve each component and further characterize the lens system. Furthermore, for the most recent events, comparison of the lens flux estimates from images taken immediately to those estimated from images taken when the lens and source are resolved can be used to empirically check the robustness of the single-epoch method currently being used to estimate lens masses for many events.

  14. International survey of contact lens prescribing for extended wear.

    Science.gov (United States)

    Efron, Nathan; Morgan, Philip B; Woods, Craig A

    2012-02-01

    To determine the extent of extended wear (EW) contact lens prescribing worldwide and to characterize the associated demographics and fitting patterns. Up to 1000 survey forms were sent to contact lens fitters in up to 39 countries between January and March every year for five consecutive years (2006-2010). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Survey data collected since 1997 was also analyzed to assess EW fitting trends since that time. Details for lens modality were received for 107,094 rigid and soft lens fits of which 88,392 were for soft lens daily wear (DW) and 7470 were for soft lens EW. Overall, EW represents 7.8% of all soft lens fits, ranging from 0.6% in Malaysia to 27% Norway. Compared with DW fittings, EW fittings can be characterized as follows: older age (32.7 ± 13.6 vs. 29.4 ± 12.0 years for DW); males are over-represented; greater proportion of refits; 72% silicone hydrogel; higher proportion of presbyopia and spherical designs; and higher proportion of monthly lens replacement. Of those wearing EW lenses, 80% use multipurpose solutions, whereas 9% do not use any care system. Between 1997 and 1999, the rate of EW prescribing decreased from 5 to 1% of all soft lens fits; it increased to a peak of 12% in 2006, and settled back to 8% by 2010. EW prescribing has failed to break through the "glass ceiling" of 15% and is unlikely to become a mainstream lens wearing modality until the already low risks of ocular complications can be reduced to be equivalent to that for DW.

  15. Dose limits to the eye lens

    Energy Technology Data Exchange (ETDEWEB)

    Sion, N.

    2016-09-15

    Protecting the human body from the effects of ionizing radiation is essential to forestall stochastic effects and require placing limits on the effective dose. Dose limits on specific organs are also necessary to reduce the deterministic effects and tissue reactions. The standard for radiation protection was ISO 15382 (2002) which mainly dealt with beta radiation for nuclear power plant workers. Clearly an update is required to allow for new technology and the proliferative use of radiation in medical practices. There is a need for more explicit radiation monitoring to operators and staff. ICRP118 (International Commission on Radiological Protection), Ref. 1, evolved their recommendations to include eye lens doses as a follow on to their publication 103 and to focus on radiation exposures. It provides updated estimates of 'practical' threshold doses for tissue injury at the level of 1% incidence. This paper discusses the current status and the recommendation for a drastic reduction of the dose limit to the eye lens. (author)

  16. Scleral lens for keratoconus: technology update

    Directory of Open Access Journals (Sweden)

    Rathi VM

    2015-10-01

    Full Text Available Varsha M Rathi,1 Preeji S Mandathara,2 Mukesh Taneja,1 Srikanth Dumpati,1 Virender S Sangwan1 1L V Prasad Eye Institute, Hyderabad, India; 2School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia Abstract: Scleral lenses are large diameter lenses which rest over the sclera, unlike the conventional contact lenses which rest on the cornea. These lenses are fitted to not touch the cornea and there is a space created between the cornea and the lens. These lenses are inserted in the eyes after filling with sterile isotonic fluid. Generally, scleral contact lenses are used for high irregular astigmatism as seen in various corneal ectatic diseases such as keratoconus, pellucid marginal degeneration, or/and as liquid bandage in ocular surface disorders. In this article, we review the new developments, that have taken place over the years, in the field of scleral contact lenses as regard to new designs, materials, manufacturing technologies, and fitting strategies particularly for keratoconus. Keywords: keratoconus, scleral lens, technology update, PROSE

  17. Curiosity's Mars Hand Lens Imager (MAHLI) Investigation

    Science.gov (United States)

    Edgett, Kenneth S.; Yingst, R. Aileen; Ravine, Michael A.; Caplinger, Michael A.; Maki, Justin N.; Ghaemi, F. Tony; Schaffner, Jacob A.; Bell, James F.; Edwards, Laurence J.; Herkenhoff, Kenneth E.; Heydari, Ezat; Kah, Linda C.; Lemmon, Mark T.; Minitti, Michelle E.; Olson, Timothy S.; Parker, Timothy J.; Rowland, Scott K.; Schieber, Juergen; Sullivan, Robert J.; Sumner, Dawn Y.; Thomas, Peter C.; Jensen, Elsa H.; Simmonds, John J.; Sengstacken, Aaron J.; Wilson, Reg G.; Goetz, Walter

    2012-01-01

    The Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) investigation will use a 2-megapixel color camera with a focusable macro lens aboard the rover, Curiosity, to investigate the stratigraphy and grain-scale texture, structure, mineralogy, and morphology of geologic materials in northwestern Gale crater. Of particular interest is the stratigraphic record of a ?5 km thick layered rock sequence exposed on the slopes of Aeolis Mons (also known as Mount Sharp). The instrument consists of three parts, a camera head mounted on the turret at the end of a robotic arm, an electronics and data storage assembly located inside the rover body, and a calibration target mounted on the robotic arm shoulder azimuth actuator housing. MAHLI can acquire in-focus images at working distances from ?2.1 cm to infinity. At the minimum working distance, image pixel scale is ?14 μm per pixel and very coarse silt grains can be resolved. At the working distance of the Mars Exploration Rover Microscopic Imager cameras aboard Spirit and Opportunity, MAHLI?s resolution is comparable at ?30 μm per pixel. Onboard capabilities include autofocus, auto-exposure, sub-framing, video imaging, Bayer pattern color interpolation, lossy and lossless compression, focus merging of up to 8 focus stack images, white light and longwave ultraviolet (365 nm) illumination of nearby subjects, and 8 gigabytes of non-volatile memory data storage.

  18. An adjustable electron achromat for cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M., E-mail: rtromp@us.ibm.com [IBM T.J. Watson Research Center, 1101 Kitchawan Road, Yorktown Heights, NY 10598 (United States); Leiden Institute of Physics, Kamerlingh Onnes Laboratory, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-12-15

    Chromatic aberration correction in light optics began with the invention of a two-color-corrected achromatic crown/flint lens doublet by Chester Moore Hall in 1730. Such color correction is necessary because any single glass shows dispersion (i.e. its index of refraction changes with wavelength), which can be counteracted by combining different glasses with different dispersions. In cathode lens microscopes (such as Photo Electron Emission Microscopy – PEEM) we encounter a similar situation, where the chromatic aberration coefficient of the cathode lens shows strong dispersion, i.e. depends (non-linearly) on the energy with which the electrons leave the sample. Here I show how a cathode lens in combination with an electron mirror can be configured as an adjustable electron achromat. The lens/mirror combination can be corrected at two electron energies by balancing the settings of the electron mirror against the settings of the cathode lens. The achromat can be adjusted to deliver optimum performance, depending on the requirements of a specific experiment. Going beyond the achromat, an apochromat would improve resolution and transmission by a very significant margin. I discuss the requirements and outlook for such a system, which for now remains a wish waiting for fulfilment. - Highlights: • The properties of cathode objective lens plus electron mirror are discussed. • In analogy with light-optical achromats, cathode lens plus mirror can be configured as an electron achromat. • Unlike light optics, the electron achromat can be adjusted to best fulfill experimental requirements.

  19. Near UV radiation effect on the lens and retina

    International Nuclear Information System (INIS)

    Zigman, S.

    1987-01-01

    The discussion presented in this paper indicates that the retina of a diurnal animal with a natural UV-absorbing lens (ie: the gray squirrel) is susceptible to near-UV damage from environmental sources only after the lens has been removed. This suggests that it is very important to protect against near-UV exposure of human eyes after cataract surgery

  20. Introduction to designing information and organizations with a positive lens

    NARCIS (Netherlands)

    Avital, M.; Boland, R.J.; Lyytinen, K.

    2009-01-01

    The role and potential contribution of a positive lens to the design of systems and organizations is the focus of this introductory essay. The positive lens refers to a perspective in the social sciences that emphasizes the capacity of people and organizations to construct better work environments,

  1. Isofocusing and immunological investigations on cephalopod lens proteins

    NARCIS (Netherlands)

    Brahma, S.K.; Lancieri, M.

    1979-01-01

    Soluble lens proteins from Octopus vulgaris, Sepia officinalis, and Loligo vulgaris were analyzed by thin-layer isoelectric focusing and compared by various immunochemical methods using antibodies directed against total soluble lens protein antigens from the said three species. The results show

  2. RETINAL BREAKS IN VITRECTOMY FOR RETAINED LENS FRAGMENTS

    NARCIS (Netherlands)

    Tan, H. Stevie; Mura, Marco; Oberstein, Sarit Y. Lesnik; Bijl, Heico M.

    2012-01-01

    Purpose: To describe the incidence and outcome of retinal breaks in vitrectomy for retained lens fragments. Methods: This is a retrospective noncomparative interventional case series. Medical records of consecutive cases of vitrectomy for retained lens fragments over a period of 4 years were

  3. The NNEST lens non native english speakers in TESOL

    CERN Document Server

    Mahboob, Ahmar

    2010-01-01

    The NNEST Lens invites you to imagine how the field of TESOL and applied linguistics can develop if we use the multilingual, multicultural, and multinational perspectives of an NNEST lens to re-examine our assumptions, practices, and theories in the field

  4. The "Youth Lens": Analyzing Adolescence/ts in Literary Texts

    Science.gov (United States)

    Petrone, Robert; Sarigianides, Sophia Tatiana; Lewis, Mark A.

    2014-01-01

    Drawing from interdisciplinary scholarship that re-conceptualizes adolescence as a cultural construct, this article introduces a "Youth Lens." A "Youth Lens" comprises an approach to textual analysis that examines how ideas about adolescence and youth get formed, circulated, critiqued, and revised. Focused specifically on its…

  5. Optimized lens-sparing treatment of retinoblastoma with electron beams

    NARCIS (Netherlands)

    Steenbakkers, RJHM; Altschuler, MD; DAngio, GJ; Goldwein, JW; Kassaee, A

    1997-01-01

    Purpose: The ideal lens-sparing radiotherapy technique for retinoblastoma calls for 100% dose to the entire retina including the ora serrata and zero dose to the lens, Published techniques, most of which use photons, have not accomplished this ideal treatment. We describe here a technique that

  6. A Broadband Metasurface-Based Terahertz Flat-Lens Array

    KAUST Repository

    Wang, Qiu

    2015-02-12

    A metasurface-based terahertz flat-lens array is proposed, comprising C-shaped split-ring resonators exhibiting locally engineerable phase discontinuities. Possessing a high numerical aperture, the planar lens array is flexible, robust, and shows excellent focusing characteristics in a broadband terahertz frequency. It could be an important step towards the development of planar terahertz focusing devices for practical applications.

  7. Prevalence of corneal ulcer among contact lens wearers in Nigeria ...

    African Journals Online (AJOL)

    Corneal Ulceration has been described as the most serious complication of contact lens wear worldwide. The incidence of corneal ulceration in contact lens wearers in Nigeria was determined retrospectively. 1759 case notes of patients who had worn contact lenses for at least one year were obtained from eye clinics in ...

  8. Incidence of contact lens-associated microbial keratitis

    NARCIS (Netherlands)

    Cheng, K.H.; Leung, S.L.; Hoekman, J.W.; Beekhuis, W.H.; Mulder, P.G.H.; Geerards, A.J.M.; Kijlstra, A.

    1999-01-01

    Background. The incidence of contact-lens-associated microbial keratitis is uncertain and its related morbidity in the general population of contact-lens wearers is not known. We examined these issues in a prospective epidemiological study. Methods. We surveyed all practising ophthalmologists in the

  9. Patient acceptability of the Tecnis® multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Sood P

    2011-03-01

    Full Text Available Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractive multifocal lens design. The design aims to minimize spherical aberration and improve range of focus. The purpose of this review is to assess patient acceptability of the Tecnis® multifocal intraocular lens.Keywords: Tecnis®, intraocular lens, multifocal, presbyopia 

  10. Composite modified Luneburg model of human eye lens.

    Science.gov (United States)

    Gómez-Correa, J E; Balderas-Mata, S E; Pierscionek, B K; Chávez-Cerda, S

    2015-09-01

    A new lens model based on the gradient-index Luneburg lens and composed of two oblate half spheroids of different curvatures is presented. The spherically symmetric Luneburg lens is modified to create continuous isoindicial contours and to incorporate curvatures that are similar to those found in a human lens. The imaging capabilities of the model and the changes in the gradient index profile are tested for five object distances, for a fixed geometry and for a fixed image distance. The central refractive index decreases with decreasing object distance. This indicates that in order to focus at the same image distance as is required in the eye, a decrease in refractive power is needed for rays from closer objects that meet the lens surface at steeper angles compared to rays from more distant objects. This ensures a highly focused image with no spherical aberration.

  11. Design of LED projector based on gradient-index lens

    Science.gov (United States)

    Qian, Liyong; Zhu, Xiangbing; Cui, Haitian; Wang, Yuanhang

    2018-01-01

    In this study, a new type of projector light path is designed to eliminate the deficits of existing projection systems, such as complex structure and low collection efficiency. Using a three-color LED array as the lighting source, by means of the special optical properties of a gradient-index lens, the complex structure of the traditional projector is simplified. Traditional components, such as the color wheel, relay lens, and mirror, become unnecessary. In this way, traditional problems, such as low utilization of light energy and loss of light energy, are solved. With the help of Zemax software, the projection lens is optimized. The optimized projection lens, LED, gradient-index lens, and digital micromirror device are imported into Tracepro. The ray tracing results show that both the utilization of light energy and the uniformity are improved significantly.

  12. Planar optical correlators integrated with binary optical lens.

    Science.gov (United States)

    Xu, Ping; Hong, Chunquan; Cheng, Guanxiao; Zhou, Liang; Sun, Zhilong

    2015-03-09

    Planar optical correlators (POCs) can achieve smaller volume of optical system and hence have important applications to identify dynamic targets in complex scenarios. POCs, however, generally have serious astigmatism and optical efficiency loss introduced by its refractive lens with a zigzag optical beam. To conquer the disadvantages of POCs, we propose a type of binary optical planar-integrated optical correlator. The correlator incorporates two pieces of reflective binary optical lens as Fourier transform lens and one spatial light modulator as a programmable filter. The off-axis aberrations commonly occurred in POCs can be corrected by using reflective binary optical lens instead of refractive lens. As a model of hybrid numerical-optical correlator using optoelectronic interface, the proposal is helpful to improve the integration and flexibility and robustness of POCs.

  13. Dielectrically embedded flat mesh lens for millimeter waves applications.

    Science.gov (United States)

    Pisano, Giampaolo; Ng, Ming Wah; Ozturk, Fahri; Maffei, Bruno; Haynes, Vic

    2013-04-10

    A flat lens based on subwavelength periodic metal meshes has been developed using photolithographic techniques. These mesh grids are stacked at specific distances and embedded in polypropylene. A code was developed to optimize more than 1000 transmission line circuits required to vary the device phase shift across the lens flat surface, mimicking the behavior of a classical lens. A W-band mesh-lens prototype was successfully manufactured and its RF performance characterized using a vector network analyzer coupled to corrugated horn antennas. Co-polarization far-field beam patterns were measured and compared with finite-element method models. The excellent agreement between data and simulations validated our designing tools and manufacturing procedures. This mesh lens is a low-loss, robust, light, and compact device that has many potential applications including millimeter wave quasi-optical systems for future cosmic microwave background polarization instruments.

  14. Subject-Oriented Programming

    Science.gov (United States)

    Coggins, James M.

    Object-Oriented Programming is enabled by advances in compiler technology and programming language design supporting encapsulation and inheritance. This technical adjustment has had a surprisingly broad impact on strategies for design and development of software. This paper explains what Object-Oriented Programming is, why it has attracted so much interest, and then critically examines its impact. The conclusion is that the optimal use of OOP occurs when application clients are empowered to contribute to the inspection, testing and development of the software they need, in a strategy I call Subject-Oriented Programming. The paper concludes by examining what the next important advance in software technology is likely to be.

  15. Orientation of Hittite Monuments

    Science.gov (United States)

    González-García, A. César; Belmonte, Juan Antonio

    The possible astronomical or topographical orientations of the Hittite monuments of the Bronze Age has remained unexplored until recently. This would provide an important insight into how temporality was imprinted by this culture in sacred spaces and in the landscape. The authors' analysis of a statistically significant sample of Hittite temples - and a few monumental gates - has demonstrated that ancient Hittite monuments were not randomly orientated as previously thought. On the contrary, there were well-defined patterns of orientation that can be interpreted within the context of Hittite culture and religion.

  16. Developing the Regulatory Utility of the Exposome: Mapping Exposures for Risk Assessment through Lifestage Exposome Snapshots (LEnS).

    Science.gov (United States)

    Shaffer, Rachel M; Smith, Marissa N; Faustman, Elaine M

    2017-08-07

    Exposome-related efforts aim to document the totality of human exposures across the lifecourse. This field has advanced rapidly in recent years but lacks practical application to risk assessment, particularly for children's health. Our objective was to apply the exposome to children's health risk assessment by introducing the concept of Lifestage Exposome Snapshots (LEnS). Case studies are presented to illustrate the value of the framework. The LEnS framework encourages organization of exposome studies based on windows of susceptibility for particular target organ systems. Such analyses will provide information regarding cumulative impacts during specific critical periods of the life course. A logical extension of this framework is that regulatory standards should analyze exposure information by target organ, rather than for a single chemical only or multiple chemicals grouped solely by mechanism of action. The LEnS concept is a practical refinement to the exposome that accounts for total exposures during particular windows of susceptibility in target organ systems. Application of the LEnS framework in risk assessment and regulation will improve protection of children's health by enhancing protection of sensitive developing organ systems that are critical for lifelong health and well-being. https://doi.org/10.1289/EHP1250.

  17. Force analysis of bacterial transmission from contact lens cases to corneas, with the contact lens as the intermediary

    NARCIS (Netherlands)

    Qu, Wen-wen; Hooymans, Johanna MM; de Vries, Jacob; van der Mei, Henderina; Busscher, Hendrik

    PURPOSE. To determine the probability of transmission of a Staphylococcus aureus strain from a contact lens case, to the contact lens (CL) surfaces, to the cornea, on the basis of bacterial adhesion forces measured by using atomic force microscopy (AFM). METHODS. Adhesion forces between S. aureus

  18. The Sloan Lens ACS Survey. I. A large spectroscopically selected sample of massive early-type lens galaxies

    NARCIS (Netherlands)

    Bolton, AS; Burles, S; Koopmans, LVE; Treu, T; Moustakas, LA

    2006-01-01

    The Sloan Lens ACS (SLACS) Survey is an efficient Hubble Space Telescope (HST) Snapshot imaging survey for new galaxy-scale strong gravitational lenses. The targeted lens candidates are selected spectroscopically from the Sloan Digital Sky Survey (SDSS) database of galaxy spectra for having multiple

  19. Bacterial transmission from lens storage cases to contact lenses - Effects of lens care solutions and silver impregnation of cases

    NARCIS (Netherlands)

    Vermeltfoort, Pit B. J.; Hooymans, Johanna M. M.; Busscher, Henk J.; van der Mei, Henny C.

    2008-01-01

    The killing efficacies of multipurpose lens care solutions on planktonic and biofilm bacteria grown in polypropylene contact lens storage cases with and without silver impregnation and effects on bacterial transmission from storage cases to silicone hydrogel contact lenses were investigated. For

  20. Design and analysis of an adaptive lens that mimics the performance of the crystalline lens in the human eye

    Science.gov (United States)

    Santiago-Alvarado, Agustin; Cruz-Félix, Angel S.; Iturbide-Jiménez, F.; Martínez-López, M.; Ramírez-Como, M.; Armengol-Cruz, V.; Vásquez-Báez, I.

    2014-09-01

    Tunable lenses are optical systems that have attracted much attention due to their potential applications in such areas like ophthalmology, machine vision, microscopy and laser processing. In recent years we have been working in the analysis and performance of a liquid-filled variable focal length lens, this is a lens that can modify its focal length by changing the amount of water within it. Nowadays we extend our study to a particular adaptive lens known as solid elastic lens (SEL) that it is formed by an elastic main body made of Polydimethylsiloxane (PDMS Sylgard 184). In this work, we present the design, simulation and analysis of an adaptive solid elastic lens that in principle imitates the accommodation process of the crystalline lens in the human eye. For this work, we have adopted the parameters of the schematic eye model developed in 1985 by Navarro et al.; this model represents the anatomy of the eye as close as possible to reality by predicting an acceptable and accurate quantity of spherical and chromatic aberrations without any shape fitting. An opto-mechanical analysis of the accommodation process of the adaptive lens is presented, by simulating a certain amount of radial force applied onto the SEL using the finite element method with the commercial software SolidWorks®. We also present ray-trace diagrams of the simulated compression process of the adaptive lens using the commercial software OSLO®.

  1. Effects of lens motion and uneven magnification on image spectra

    Science.gov (United States)

    Banik, Indranil; Zhao, Hongsheng

    2015-07-01

    Counter to intuition, the images of an extended galaxy lensed by a moving galaxy cluster should have slightly different spectra in any metric gravity theory. This is mainly for two reasons. One relies on the gravitational potential of a moving lens being time dependent (the moving cluster effect, MCE). The other is due to uneven magnification across the extended, rotating source (the differential magnification effect, DME). The time delay between the images can also cause their redshifts to differ because of cosmological expansion. This differential expansion effect is likely to be small. Using a simple model, we derive these effects from first principles. One application would be to the Bullet Cluster, whose large tangential velocity may be inconsistent with the Λ cold dark matter paradigm. This velocity can be estimated with complicated hydrodynamic models. Uncertainties with such models can be avoided using the MCE. We argue that the MCE should be observable with Atacama Large Millimetre Array. However, such measurements can be corrupted by the DME if typical spiral galaxies are used as sources. Fortunately, we find that if detailed spectral line profiles were available, then the DME and MCE could be distinguished. It might also be feasible to calculate how much the DME should affect the mean redshift of each image. Resolved observations of the source would be required to do this accurately. The DME is of order the source angular size divided by the Einstein radius times the redshift variation across the source. Thus, it mostly affects nearly edge-on spiral galaxies in certain orientations. This suggests that observers should reduce the DME by careful choice of target, a possibility we discuss in some detail.

  2. Implementing Strategic Orientation

    Science.gov (United States)

    Fischer, Arthur K.; Brownback, Sarah

    2012-01-01

    An HRM case dealing with problems and issues of setting up orientation programs which align with corporate strategy. Discussion concerns how such a case can be used to exhibit the alignment between HRM and business strategy.

  3. Time lens assisted photonic sampling extraction

    Science.gov (United States)

    Petrillo, Keith Gordon

    Telecommunication bandwidth demands have dramatically increased in recent years due to Internet based services like cloud computing and storage, large file sharing, and video streaming. Additionally, sensing systems such as wideband radar, magnetic imaging resonance systems, and complex modulation formats to handle large data transfer in telecommunications require high speed, high resolution analog-to-digital converters (ADCs) to interpret the data. Accurately processing and acquiring the information at next generation data rates from these systems has become challenging for electronic systems. The largest contributors to the electronic bottleneck are bandwidth and timing jitter which limit speed and reduce accuracy. Optical systems have shown to have at least three orders of magnitude increase in bandwidth capabilities and state of the art mode locked lasers have reduced timing jitters into thousands of attoseconds. Such features have encouraged processing signals without the use of electronics or using photonics to assist electronics. All optical signal processing has allowed the processing of telecommunication line rates up to 1.28 Tb/s and high resolution analog-to-digital converters in the 10s of gigahertz. The major drawback to these optical systems is the high cost of the components. The application of all optical processing techniques such as a time lens and chirped processing can greatly reduce bandwidth and cost requirements of optical serial to parallel converters and push photonically assisted ADCs into the 100s of gigahertz. In this dissertation, the building blocks to a high speed photonically assisted ADC are demonstrated, each providing benefits to its own respective application. A serial to parallel converter using a continuously operating time lens as an optical Fourier processor is demonstrated to fully convert a 160-Gb/s optical time division multiplexed signal to 16 10-Gb/s channels with error free operation. Using chirped processing, an

  4. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. [Seoul National University Hospital (Korea, Republic of)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  5. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  6. [Intraocular lens implantation with one loop haptic amputated: a new propose to the subluxation lens surgical treatment].

    Science.gov (United States)

    Ventura, Marcelo; Endriss, Daniela

    2010-01-01

    To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 +/- 5.4 years old, and the mean follow-up period was 21.5 +/- 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL) implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (psubluxation surgical treatment, promoting lens centralization and postoperative visual acuity improvement.

  7. Cultural Orientation and Interdisciplinarity

    DEFF Research Database (Denmark)

    Nielsen, Sofie Søndergaard

    2004-01-01

    I begin the article with an account of the background to the German debate on ‘Literaturwissenschaft als Kulturwissenschaft’, including the introduction of the concept of ’cultural orientation’ as a strategy for achieving interdisciplinarity. This is followed by a consideration of the discussion ...... of the object of literary studies as a way of defining the disciplinarity or identity of literary studies. Finally I summarize some of the characteristics of culturally orientated literary studies....

  8. Perubahan Sosial Berbasis Tasawuf: Studi Kasus Fethullah Gülen Dan Gülen Movement

    Directory of Open Access Journals (Sweden)

    Sulaiman Sulaiman

    2016-06-01

    Full Text Available Abstract: This article aims at analyzing Fethullah Gülen and the Gülen Movement which have succeeded in performing social change based on the teaching of Sufism. He did Sufism creativity in order that Sufism teaching was able to respond the changes that occur in the modernlife. He believed that, only by reinterpretation and contextualization of Sufism, the spiritual dimension of Islam would be able to perform the transformation or social change among the Muslims. Therefore, by using Max Weber’s theory of social action, this paper will analyze three key teachings of Sufism of Gülen: ascetic (zuhd, inbisat (expansion, and hizmet. Based on the Weber's theory, Gülen occupied a very central and authoritative position: agent/actor, action and meaning. As a source of meaning and interpreter of meaning, the key concepts of Sufism were transformed by Gülen to the internal and external communities so that they had made a move to do social movements and humanity. For the followers of Gülen, the movement was called the Gülen Movement or the Hizmet Movement which was engaged in the fields of education, health care, humanitarian assistance, and the mass media. All forms of movement were entirely based on the spiritual values of Islam that had been formulated by Gülen. الملخص: يهدف هذا البحث إلى تحليل شخصية فتح الله غولن وحركته الذي تمكن من القيام بالتغيير الاجتماعي على أساس التعاليم الصوفية. إن فتح الله غولن قام بإحياء التصوف في صورته الجدّية والحيوية في حياة الإنسان المعاصر. ويعتقد أن إعادة التفسير لتعاليم التصوف مع مراعاة الواقع قادرة على التغيير الاجتماعي بين المسلمين. من أجل ذلك، أن استخدام نظرية ويبر، يمكن تحليل تعاليم التصوف الثلاثة

  9. High gradient lens for charged particle beam

    Science.gov (United States)

    Chen, Yu-Jiuan

    2014-04-29

    Methods and devices enable shaping of a charged particle beam. A dynamically adjustable electric lens includes a series of alternating a series of alternating layers of insulators and conductors with a hollow center. The series of alternating layers when stacked together form a high gradient insulator (HGI) tube to allow propagation of the charged particle beam through the hollow center of the HGI tube. A plurality of transmission lines are connected to a plurality of sections of the HGI tube, and one or more voltage sources are provided to supply an adjustable voltage value to each transmission line of the plurality of transmission lines. By changing the voltage values supplied to each section of the HGI tube, any desired electric field can be established across the HGI tube. This way various functionalities including focusing, defocusing, acceleration, deceleration, intensity modulation and others can be effectuated on a time varying basis.

  10. Accuracy of fish-eye lens models.

    Science.gov (United States)

    Hughes, Ciarán; Denny, Patrick; Jones, Edward; Glavin, Martin

    2010-06-10

    The majority of computer vision applications assumes that the camera adheres to the pinhole camera model. However, most optical systems will introduce undesirable effects. By far, the most evident of these effects is radial lensing, which is particularly noticeable in fish-eye camera systems, where the effect is relatively extreme. Several authors have developed models of fish-eye lenses that can be used to describe the fish-eye displacement. Our aim is to evaluate the accuracy of several of these models. Thus, we present a method by which the lens curve of a fish-eye camera can be extracted using well-founded assumptions and perspective methods. Several of the models from the literature are examined against this empirically derived curve.

  11. Scleral lens for keratoconus: technology update

    Science.gov (United States)

    Rathi, Varsha M; Mandathara, Preeji S; Taneja, Mukesh; Dumpati, Srikanth; Sangwan, Virender S

    2015-01-01

    Scleral lenses are large diameter lenses which rest over the sclera, unlike the conventional contact lenses which rest on the cornea. These lenses are fitted to not touch the cornea and there is a space created between the cornea and the lens. These lenses are inserted in the eyes after filling with sterile isotonic fluid. Generally, scleral contact lenses are used for high irregular astigmatism as seen in various corneal ectatic diseases such as keratoconus, pellucid marginal degeneration, or/and as liquid bandage in ocular surface disorders. In this article, we review the new developments, that have taken place over the years, in the field of scleral contact lenses as regard to new designs, materials, manufacturing technologies, and fitting strategies particularly for keratoconus. PMID:26604671

  12. Hyperbolic metamaterial lens with hydrodynamic nonlocal response

    DEFF Research Database (Denmark)

    Yan, Wei; Mortensen, N. Asger; Wubs, Martijn

    2013-01-01

    We investigate the effects of hydrodynamic nonlocal response in hyperbolic metamaterials (HMMs), focusing on the experimentally realizable parameter regime where unit cells are much smaller than an optical wavelength but much larger than the wavelengths of the longitudinal pressure waves of the f......We investigate the effects of hydrodynamic nonlocal response in hyperbolic metamaterials (HMMs), focusing on the experimentally realizable parameter regime where unit cells are much smaller than an optical wavelength but much larger than the wavelengths of the longitudinal pressure waves...... in the local-response approximation and in the hydrodynamic Drude model can differ considerably. In particular, the optimal frequency for imaging in the nonlocal theory is blueshifted with respect to that in the local theory. Thus, to detect whether nonlocal response is at work in a hyperbolic metamaterial, we...... propose to measure the near-field distribution of a hyperbolic metamaterial lens....

  13. CERN through the lens of Peter Ginter

    CERN Multimedia

    2008-01-01

    This summer, passers-by along the Quai Wilson on the banks of Lake Geneva will be able to enjoy an unusual exhibition of photographs devoted to CERN and the LHC. Fifty images from the work of Peter Ginter, organized into themes, give strollers on the Quai Wilson a glimpse of the unique human and scientific adventure at CERN. An exhibition panel, showing a scientist against the background of ALICE’s huge red electromagnet.CERN will reach an important milestone in 2008 with the start-up of the LHC, opening a new window on our Universe for physicists around the world. To celebrate this event with the people who live around Lake Geneva and visitors to the area, CERN and the city of Geneva are jointly putting on the photography exhibition "CERN through the lens of Peter Ginter", which opens on 29 May. A group of some fifty images taken by the German photo...

  14. Hospitality as lens for migration studies

    DEFF Research Database (Denmark)

    Greve, Anni

    there are limits to its financial resources. What is more, the focus on claim-making and extended rights of the migrant produces a tendency for the language and practice of hospitality to ‘turn’ against the guest today, and notably the construction of the figure of guests who not only fail to fulfil their duties...... (welfare ‘parasites’) but even betray the host. Next, an enquiry of the concept of hospitality as possible lens for migration studies; it implies a twofold analyses with two levels, a macro level, to focus our attention to the modalities of hospitality given by the juridical status of the stranger and its...... influence on civil inclusion (Sassen 2007; Brenner 2011); and a meso level, to focus instead upon hospitality as an inter-subjective relationship between the host and the guest as a way to relate, as an experience and as an ethics (Derrida 2001). Finally the paper gives a short introduction into an on...

  15. Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2013-04-01

    Full Text Available PURPOSE: To evaluate distance and near contrast sensitivity (CS under photopic and mesopic conditions before and after refractive lens exchange (RLE and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model intraocular lens (IOL. METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m² before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. RESULTS: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002. CONCLUSIONS: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.

  16. Aspherical Lens Design Using Genetic Algorithm for Reducing Aberrations in Multifocal Artificial Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Chih-Ta Yen

    2015-09-01

    Full Text Available A complex intraocular lens (IOL design involving numerous uncertain variables is proposed. We integrated a genetic algorithm (GA with the commercial optical design software of (CODE V to design a multifocal IOL for the human eye. We mainly used an aspherical lens in the initial state to the crystalline type; therefore, we used the internal human eye model in the software. The proposed optimized algorithm employs a GA method for optimally simulating the focusing function of the human eye; in this method, the thickness and curvature of the anterior lens and the posterior part of the IOL were varied. A comparison of the proposed GA-designed IOLs and those designed using a CODE V built-in optimal algorithm for 550 degrees myopia and 175 degrees astigmatism conditions of the human eye for pupil size 6 mm showed that the proposed IOL design improved the spot size of root mean square (RMS, tangential coma (TCO and modulation transfer function (MTF at a spatial frequency of 30 with a pupil size of 6 mm by approximately 17%, 43% and 35%, respectively. However, the worst performance of spherical aberration (SA was lower than 46%, because the optical design involves a tradeoff between all aberrations. Compared with the traditional CODE V built-in optimal scheme, the proposed IOL design can efficiently improve the critical parameters, namely TCO, RMS, and MTF.

  17. Lens dislocation has a possible relationship with laser iridotomy

    Directory of Open Access Journals (Sweden)

    Mutoh T

    2012-12-01

    Full Text Available Tetsuya Mutoh,1,2 Kevin F Barrette,2 Yukihiro Matsumoto,1 Makoto Chikuda11Department of Ophthalmology, Dokkyo Medical University Koshigaya Hospital, Koshigaya City, Saitama, Japan; 2Department of Ophthalmology, Boston University School of Medicine, Boston, MA, USAAbstract: We report our recent experience of four eyes with spontaneous lens dislocation in four patients with no history of trauma or any systemic disease associated with zonular dialysis. Lens dislocation developed with 0.5 to 6 months following laser iridotomy. All patients were male and two eyes were complicated with acute primary angle closure glaucoma preoperatively. Case 1 showed bilateral lens dislocation, while cases 2 and 3 involved unilateral lens dislocation. Cases 2 and 3 showed lenses completely dislocated into the vitreous cavity. All cases needed lens removal and scleral fixation of intraocular lenses. Final visual acuity was 1.2 in all cases. We suspect that laser iridotomy may induce localized zonular dialysis that results in progressive zonular weakness, leading to lens dislocation.Keywords: lens dislocation, laser iridotomy, primary angle closure glaucoma

  18. c-Myc regulates cell proliferation during lens development.

    Directory of Open Access Journals (Sweden)

    Gabriel R Cavalheiro

    Full Text Available Myc protooncogenes play important roles in the regulation of cell proliferation, growth, differentiation and survival during development. In various developing organs, c-myc has been shown to control the expression of cell cycle regulators and its misregulated expression is detected in many human tumors. Here, we show that c-myc gene (Myc is highly expressed in developing mouse lens. Targeted deletion of c-myc gene from head surface ectoderm dramatically impaired ocular organogenesis, resulting in severe microphtalmia, defective anterior segment development, formation of a lens stalk and/or aphakia. In particular, lenses lacking c-myc presented thinner epithelial cell layer and growth impairment that was detectable soon after its inactivation. Defective development of c-myc-null lens was not caused by increased cell death of lens progenitor cells. Instead, c-myc loss reduced cell proliferation, what was associated with an ectopic expression of Prox1 and p27(Kip1 proteins within epithelial cells. Interestingly, a sharp decrease in the expression of the forkhead box transcription factor Foxe3 was also observed following c-myc inactivation. These data represent the first description of the physiological roles played by a Myc family member in mouse lens development. Our findings support the conclusion that c-myc regulates the proliferation of lens epithelial cells in vivo and may, directly or indirectly, modulate the expression of classical cell cycle regulators in developing mouse lens.

  19. Surgical effect of traumatic lens dislocation with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Xiao-Dan Zhang

    2014-10-01

    Full Text Available AIM: To retrospectively evaluate the effect of lens extraction combined with vitrectomy to treat traumatic lens dislocation with secondary glaucoma.METHODS:Thirty-one eyes(31 casesof lens dislocation caused by blunt trauma with secondary glaucoma were treated respectively with cataract extraction combined with anterior vitrectomy, trabeculectomy and intraocular lens implantation. The visual acuity and pressure were observed 1wk, 1 and 3mo after operative. RESULTS:Thirty-one eyes were all complete the operation successfully, and 6 eyes were given combined trabeculectomy, 9 eyes were implanted anterior chamber intraocular lens implantation(IOLand 15 eyes were given posterior chamber suture fixation. Sixteen eyes were implanted in one-stage operation, while 8 eyes were implanted in two-stage operation. All intraocular pressure(IOPwere controlled to the normal level after operation and 23 eyes had visual acuity of more than 0.3.CONCLUSION:Lens extraction combined with vitrectomy is an effective method for treatment of lens dislocation with secondary glaucoma. In order to control the IOP and get well visual function, we should choose IOL implantation or trabeculectomy according to the patient's condition.

  20. Hyperelastic modelling of the crystalline lens: Accommodation and presbyopia

    Science.gov (United States)

    Lanchares, Elena; Navarro, Rafael; Calvo, Begoña

    2012-01-01

    Purpose The modification of the mechanical properties of the human crystalline lens with age can be a major cause of presbyopia. Since these properties cannot be measured in vivo, numerical simulation can be used to estimate them. We propose an inverse method to determine age-dependent change in the material properties of the tissues composing the human crystalline lens. Methods A finite element model of a 30-year-old lens in the accommodated state was developed. The force necessary to achieve full accommodation in a 30-year-old lens of known external geometry was computed using this model. Two additional numerical models of the lens corresponding to the ages of 40 and 50 years were then built. Assuming that the accommodative force applied to the lens remains constant with age, the material properties of nucleus and cortex were estimated by inverse analysis. Results The zonular force necessary to reshape the model of a 30-year-old lens from the accommodated to the unaccommodated geometry was 0.078 newton (N). Both nucleus and cortex became stiffer with age. The stiffness of the nucleus increased with age at a higher rate than the cortex. Conclusions In agreement with the classical theory of Helmholtz, on which we based our model, our results indicate that a major cause of presbyopia is that both nucleus and cortex become stiffer with age; therefore, a constant value of the zonular forces with aging does not achieve full accommodation, that is, the accommodation capability decreases.

  1. White LED motorcycle headlamp design

    Science.gov (United States)

    Sun, Wen-Shing

    2015-09-01

    The motorcycle headlamp is composed of a white LED module, an elliptical reflector, a parabolic reflector and a toric lens. We use non-sequential ray to improve the optical efficiency of the compound reflectors. Using the toric lens can meet ECE_113 regulation and obtain a good uniformity.

  2. Effects of x-irradiation on lens reducing systems. [Rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Giblin, F.J.; Chakrapani, B.; Reddy, V.N.

    1978-01-01

    Studies have been made of the effects of x ray on various lens reducing systems including the levels of NADPH and glutathione (GSH), the activity of the hexose monophosphate shunt (HMS), and the activities of certain enzymes including glutathion reductase, glutathione peroxidase, and glucose-6-phosphate dehydrogenase (G-6-PD). It was found that during several weeks following x irradiation but prior to cataract formation there was very little change in the number of reduced -SH groups per unit weight of lens protein but that, with the appearance of cataract, there was a sudden loss of protein -SH groups. In contrast, the concentration of GSH in the x-rayed lens decreased throughout the experimental period. Similarly, the concentration of NADPH in the x-rayed lens was found to decrease significantly relative to controls one week prior to cataract formation and the ratio of NADPH to NADP/sup +/ in the lens shifted at this time period from a value greater than 1.0 in the control lens to less than 1.0 in the x-rayed lens. A corresponding decrease occurred in the activity of the HMS in x-rayed lenses as measured by culture in the presence of 1-/sup 14/C-labelled glucose. G-6-PD was partially inactivated in the x-rayed lens. Of the eight enzymes studied, G-6-PD appeared to be the most sensitive to x-irradiation. The data indicate that x-irradiation results in a steady decrease in the effectiveness of lens reducing systems and that, when these systems reach a critically low point, sudden oxidation of protein -SH groups and formation of high molecular weight protein aggregates may be initiated.

  3. Effects of x-irradiation on lens reducing systems

    International Nuclear Information System (INIS)

    Giblin, F.J.; Chakrapani, B.; Reddy, V.N.

    1978-01-01

    Studies have been made of the effects of x ray on various lens reducing systems including the levels of NADPH and glutathione (GSH), the activity of the hexose monophosphate shunt (HMS), and the activities of certain enzymes including glutathion reductase, glutathione peroxidase, and glucose-6-phosphate dehydrogenase (G-6-PD). It was found that during several weeks following x irradiation but prior to cataract formation there was very little change in the number of reduced -SH groups per unit weight of lens protein but that, with the appearance of cataract, there was a sudden loss of protein -SH groups. In contrast, the concentration of GSH in the x-rayed lens decreased throughout the experimental period. Similarly, the concentration of NADPH in the x-rayed lens was found to decrease significantly relative to controls one week prior to cataract formation and the ratio of NADPH to NADP + in the lens shifted at this time period from a value greater than 1.0 in the control lens to less than 1.0 in the x-rayed lens. A corresponding decrease occurred in the activity of the HMS in x-rayed lenses as measured by culture in the presence of 1- 14 C-labelled glucose. G-6-PD was partially inactivated in the x-rayed lens. Of the eight enzymes studied, G-6-PD appeared to be the most sensitive to x-irradiation. The data indicate that x-irradiation results in a steady decrease in the effectiveness of lens reducing systems and that, when these systems reach a critically low point, sudden oxidation of protein -SH groups and formation of high molecular weight protein aggregates may be initiated

  4. PENGARUH CUSTOMER ORIENTATION DAN COMPETITIVE ORIENTATION TERHADAP CUSTOMER SATISFACTION MELALUI SALESPERSON CUSTOMER ORIENTATION

    OpenAIRE

    Adiyanto, Yoga; Sunaryo, Deni

    2017-01-01

    The empirical investigation examines the influence of customer orientation and competitive orientation to customer satisfaction mediating with salesperson customer orientation in Smart Telecom company.The objective of this research was investigated the influence of customer orientation and competitive orientation to customer satisfaction mediating with salesperson customer orientation in Smart Telecom company.The design of this research using hypotheses testing in the influence of customer or...

  5. Means to flexibly attach lens frames to temple members

    Science.gov (United States)

    Smith, Harry D.

    1995-01-01

    The invention is a band hinge for flexibly connecting the temple member to the lens frame thereby preventing damage from inadvertent pressure or cyclic wear. A distinguishing feature of the invention is the use of a band hinge that holds together the temple member and the lens frame without the use of a pin or screw hinging mechanism. The invention allows for a high degree of freedom of movement for the temple member with respect to the lens frame which will prevent most forms of damages to the glasses from these types of events.

  6. The gravitational lens effect and its optical equivalents

    International Nuclear Information System (INIS)

    Freitas, L.R. de.

    1987-01-01

    This work presents the evolution of the use of the so called gravitational lens effect from a simple observational teste of the General Relativity theory to an instrument to measure cosmological parameters. A detailed analysis of how a gravitational ''lens'' deflects light without forming images is shown for the case of the deflector with spherical symmetry. In addition, the exact optical equivalent of a cylindrical gravitational lens, which forms true images, is proposed. Finally the problem of the formation of multiple images and the related astronomical observations is discussed. (author) [pt

  7. Development of high precision and cryogenic lens holders

    Science.gov (United States)

    Reutlinger, A.; Boesz, Anton; Mottaghibonab, A.; Eckert, P.; Dubowy, M.; Gebler, H.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2017-11-01

    The optical system of the Near Infrared Spectrometer and Photometer (NISP) of the EUCLID mission consists mainly of a filter and grism wheel and 4 aspherical lenses with large diameters up to 170 mm. The single lenses require a high precision positioning at the operational temperature of 150 K. An additional design driver represents the CaF2 material of a lens, which is very sensitive wrt brittleness. The technical maturity of the combination of single features such as CaF2, large diameter (and mass), high precision and cryogenic conditions is considered as low. Therefore, a dedicated pre-development program has been launched to design and develop a first prototype of lens holder and to demonstrate the functional performance at representative operational conditions. The 4 lenses are divided into 3x lenses for the Camera Lens Assembly (CaLA) and 1x lens for the Corrector Lens Assembly (CoLA). Each lens is glue mounted onto solid state springs, part of an adaption ring. The adaption ring shall provide protection against vibration loads, high accuracy positioning, as well as quasi load free mounting of the lens under operational conditions. To reduce thermomechanical loads on the lens, the CTE of the adaption ring is adapted to that of the lens. The glue between lens and solid state spring has to withstand high tension loads during vibration. At the operational temperature the deviating CTE between glue and lens/adaption ring introduces shear loads into the glue interface, which are critical, in particular for the fragile CaF2 lens material. For the case of NISP the shear loads are controlled with the glue pad diameter and the glue thickness. In the context of the development activity many technology aspects such as various solid state spring designs, glue selection and glue handling have been investigated. A parametric structural model was developed to derive the specific design feature of each ring, such as spring force, number of springs, eigenfrequency, etc. This

  8. Characteristic of laser diode beam propagation through a collimating lens.

    Science.gov (United States)

    Xu, Qiang; Han, Yiping; Cui, Zhiwei

    2010-01-20

    A mathematical model of a laser diode beam propagating through a collimating lens is presented. Wave propagation beyond the paraxial approximation is studied. The phase delay of the laser diode wave in passing through the lens is analyzed in detail. The propagation optical field after the lens is obtained from the diffraction integral by the stationary phase method. The model is employed to predict the light intensity at various beam cross sections, and the computed intensity distributions are in a good agreement with the corresponding measurements.

  9. Electrostatic plasma lens for focusing negatively charged particle beams.

    Science.gov (United States)

    Goncharov, A A; Dobrovolskiy, A M; Dunets, S M; Litovko, I V; Gushenets, V I; Oks, E M

    2012-02-01

    We describe the current status of ongoing research and development of the electrostatic plasma lens for focusing and manipulating intense negatively charged particle beams, electrons, and negative ions. The physical principle of this kind of plasma lens is based on magnetic isolation electrons providing creation of a dynamical positive space charge cloud in shortly restricted volume propagating beam. Here, the new results of experimental investigations and computer simulations of wide-aperture, intense electron beam focusing by plasma lens with positive space charge cloud produced due to the cylindrical anode layer accelerator creating a positive ion stream towards an axis system is presented.

  10. Vortexlike Power Flow at the Interfaces of Metamaterial Lens

    Directory of Open Access Journals (Sweden)

    K. Fang

    2012-10-01

    Full Text Available The metamaterial lens with DPS/DNS/DPS structure has been realized by using the two-dimensional (2D isotropic transmission line approach. We studied the vortexlike power flow at the interfaces of metamaterial lens and validated by the finite-difference time-domain (FDTD simulator. The computational results showing its different conditions near DPS/DNS and other kinds of interfaces are obtained by CST STUDIO SUITE at different frequencies, and demonstrate the intuitionistic power location at the metamaterial lens interfaces.

  11. Intracapsular Lens Extraction for the Treatment of Pupillary Block Glaucoma Associated with Anterior Subluxation of the Crystalline Lens

    Directory of Open Access Journals (Sweden)

    Yong Joon Kim

    2013-11-01

    Full Text Available Purpose: To report a case of pupillary block glaucoma associated with spontaneous crystalline lens subluxation into the anterior chamber in a 34-year-old man. Methods: Dry vitrectomy was performed for securing enough retrolental space, and an intracapsular lens extraction was then performed via a corneolimbal incision. Additional endothelial cell damage was avoided with an injection of viscoelastics and gentle extraction of the crystalline lens. After deepening of the anterior chamber, scleral fixation of the intraocular lens was performed with an ab externo technique. Results: Two months after the operation, a well-fixated intraocular lens was observed and intraocular pressure was stable. The postoperative corneal astigmatism was -3.5 dpt, and the patient had a best-corrected visual acuity of 20/25. Postoperative complications included decreased endothelial cell count and sector iris paralysis near the incision site. Conclusions: An anteriorly subluxated crystalline lens can cause pupillary block glaucoma in healthy young adults. To prevent intraoperative complications, intracapsular lens extraction with dry vitrectomy can be a good surgical option. The endothelial cell density should be closely monitored after surgery.

  12. Intracapsular Lens Extraction for the Treatment of Pupillary Block Glaucoma Associated with Anterior Subluxation of the Crystalline Lens

    Science.gov (United States)

    Kim, Yong Joon; Ha, Seung Joo

    2013-01-01

    Purpose To report a case of pupillary block glaucoma associated with spontaneous crystalline lens subluxation into the anterior chamber in a 34-year-old man. Methods Dry vitrectomy was performed for securing enough retrolental space, and an intracapsular lens extraction was then performed via a corneolimbal incision. Additional endothelial cell damage was avoided with an injection of viscoelastics and gentle extraction of the crystalline lens. After deepening of the anterior chamber, scleral fixation of the intraocular lens was performed with an ab externo technique. Results Two months after the operation, a well-fixated intraocular lens was observed and intraocular pressure was stable. The postoperative corneal astigmatism was −3.5 dpt, and the patient had a best-corrected visual acuity of 20/25. Postoperative complications included decreased endothelial cell count and sector iris paralysis near the incision site. Conclusions An anteriorly subluxated crystalline lens can cause pupillary block glaucoma in healthy young adults. To prevent intraoperative complications, intracapsular lens extraction with dry vitrectomy can be a good surgical option. The endothelial cell density should be closely monitored after surgery. PMID:24348413

  13. Outcomes of Lensectomy in Hereditary Lens Subluxation

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Dehghan

    2008-12-01

    Full Text Available

    PURPOSE: To evaluate the results of pars plana lensectomy in patients with hereditary lens subluxation. METHOD: Hospital records of patients with hereditary lens subluxation who had undergone pars plana lensectomy at Labbafinejad Medical Center, Tehran-Iran from 1996 to 2003 were reviewed. Patients with more than 6 months of follow up were included. Underlying disorders, best corrected visual acuity (BCVA before and after surgery, intraocular pressure (IOP, postoperative refraction and complications were evaluated. RESULTS: Overall, records of 87 eyes of 49 patients including 27 male and 22 female subjects were reviewed. Mean follow up duration was 20±18 months. Underlying disorders leading to lens subluxation included Marfan syndrome (79.5%, Weill-Marchesani syndrome (8.2%, simple ectopia lentis (8.2%, and homocystinuria (4.1%. The most common indication for surgery was non-correctable refractive error (92.1%. Mean BCVA was 1.13 LogMAR (20/250 preoperatively, which improved to 0.26 LogMAR (20/30-20/40 postoperatively (P < 0.001. BCVA better than 20/40 was achieved in 82.8% of cases after surgery. Angle-supported anterior chamber intraocular lens (ACIOL was implanted in

  14. Age and Value Orientations

    Directory of Open Access Journals (Sweden)

    Asya Kh. Kukubayeva

    2013-01-01

    Full Text Available The present article deals with value orientations and their role in men’s lives, particularly, in young people’s lives. This notion was introduced by the American theoretical sociologist T. Parsons, one of the creators of modern theoretical sociology. The scientist made an attempt to construct the structural and analytical theory of social action, combining personal interests (needs and aims and situation, it takes place in. The issue of value orientations remains acute for psychology. Herein we have considered several most important works, relating to the considered issue. Age aspects of young people’s value orientations are of peculiar interest to us. When analyzing this phenomenon, one should take into consideration the psychological formations, inhere for a certain age. In fact every age has its unique structure, which may change when passing from one development stage to another. Basing on this fact, we’ve considered the values, depending on the age features of the youth, relying upon the works of the scientists, working with different categories of the youth, such as: teenagers, students, children of different nationalities. It is not surprising that most scientists have come to the conclusion that the chief role in value orientation belongs to a family, originates in relations with parents and teachers. The positive reinforcement to the future develops throughout life in accordance with a lifestyle of a family, society and political situation in a state.Life orientations as a type of value orientations show different types of young people’s preferences. Value structure of its consciousness has its own specific character, depending on the age peculiarities. The dynamics of the transition from one age to another is accompanied with the reappraisal of values, eventually, influencing the life strategy of the future generation

  15. The correct lens mount lightweighting design and thermal stress OPD analysis in Cassegrain telescope

    Science.gov (United States)

    Hsu, Ming-Ying; Chan, Chia-Yen; Lin, Wei-Cheng; Chang, Shenq-Tsong; Huang, Ting-Ming

    2013-09-01

    This study is trying to evaluate different lens barrel material, caused lens stress OPD (Optical Path Different) in different temperature condition. The Cassegrain telescope's correct lens assembly are including as correct lens, lens mount, spacer, mount barrel and retainer. The lens barrel initial design is made by invar, but system mass limit is need to lightweighting to meet requirement. Therefore, the lens barrel material is tried to replace to lower density material, such as aluminum and titanium alloy. Meanwhile, the aluminum or titanium alloy material properties CTE (Coefficient of Thermal Expansion) are larger then invar. Thus, the high CTE material will introduce larger thermal stress into the optical system in different temperature condition. This article is analysis the correct lens assembly thermal stress and optical performance in different lens mount material. From above conditions, using FEM (Finite Element Method) and optical software, simulation and optimization the lens mount to achieve system mass requirement.

  16. Future-Oriented LCA

    DEFF Research Database (Denmark)

    Olsen, Stig Irving; Borup, Mads; Andersen, Per Dannemand

    2017-01-01

    challenges are described and some learnings are derived. Many of the future-oriented LCAs published so far perform relatively short-term prediction of simple comparisons. But for more long-term time horizons foresight methods can be of help. Scenarios established by qualified experts about future......LCA is often applied for decision-making that concerns actions reaching near or far into the future. However, traditional life cycle assessment methodology must be adjusted for the prospective and change-oriented purposes, but no standardised way of doing this has emerged yet. In this chapter some...

  17. CFD model of a spinning pipe gas lens

    CSIR Research Space (South Africa)

    Snedden, Glen C

    2006-07-01

    Full Text Available Slides on: Spinning Pipe Gas Lens; Focal Length; Refractive Index; Gas Dynamics; Guess at the gas dynamics; Density Profile; Flow Profile; Rosby Waves; Rayleigh–Taylor Instabilities...

  18. Surface Fourier-transform lens using a metasurface

    International Nuclear Information System (INIS)

    Li, Yun Bo; Cai, Ben Geng; Cheng, Qiang; Cui, Tie Jun

    2015-01-01

    We propose a surface (or 2D) Fourier-transform lens using a gradient refractive index (GRIN) metasurface in the microwave band, which is composed of sub-wavelength quasi-periodical metallic patches on a grounded dielectric substrate. Such a metasurface supports the transverse magnetic (TM) modes of surface waves. To gradually change the size of textures, we obtain different surface refractive indices, which can be tailored to fit the required refractive-index profile of a surface Fourier-transform lens. According to the theory of spatial Fourier transformation, we make use of the proposed lens to realize surface plane-wave scanning under different feeding locations. The simulation and experimental results jointly confirm the validity of the surface Fourier-transform lens. The proposed method can also be extended to the terahertz frequency. (paper)

  19. Plasma lens experiments at the Final Focus Test Beam

    International Nuclear Information System (INIS)

    Barletta, B.; Chattopadhyay, S.; Chen, P.

    1993-04-01

    We intend to carry out a series of plasma lens experiments at the Final Focus Test Beam facility at SLAC. These experiments will be the first to study the focusing of particle beams by plasma focusing devices in the parameter regime of interest for high energy colliders, and is expected to lead to plasma lens designs capable of unprecedented spot sizes. Plasma focusing of positron beams will be attempted for the first time. We will study the effects of lens aberrations due to various lens imperfections. Several approaches will be applied to create the plasma required including laser ionization and beam ionization of a working gas. At an increased bunch population of 2.5 x 10 10 , tunneling ionization of a gas target by an electron beam -- an effect which has never been observed before -- should be significant. The compactness of our device should prove to be of interest for applications at the SLC and the next generation linear colliders

  20. Plasma lens experiments at the Final Focus Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    Barletta, B. [California Univ., Los Angeles, CA (United States)]|[Lawrence Berkeley Lab., CA (United States); Chattopadhyay, S. [Lawrence Berkeley Lab., CA (United States); Chen, P. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)] [and others

    1993-04-01

    We intend to carry out a series of plasma lens experiments at the Final Focus Test Beam facility at SLAC. These experiments will be the first to study the focusing of particle beams by plasma focusing devices in the parameter regime of interest for high energy colliders, and is expected to lead to plasma lens designs capable of unprecedented spot sizes. Plasma focusing of positron beams will be attempted for the first time. We will study the effects of lens aberrations due to various lens imperfections. Several approaches will be applied to create the plasma required including laser ionization and beam ionization of a working gas. At an increased bunch population of 2.5 {times} 10{sup 10}, tunneling ionization of a gas target by an electron beam -- an effect which has never been observed before -- should be significant. The compactness of our device should prove to be of interest for applications at the SLC and the next generation linear colliders.

  1. Applications of thermal lens spectrometry in food industry and agriculture.

    NARCIS (Netherlands)

    Franko, M.; Bicanic, D.; Gibkes, J.; Bremer, M.; Akkermans, E.

    1996-01-01

    Applications of CO laser dual beam thermal lens spectrometry (TLS) for detection and characterization of fatty acids, aldehydes, pesticides, and herbicides in liquid samples are described. Also reported is the first TLS measurement of thermal conductivity for oleic acid.

  2. LAUE lens development at UC Berkeley: status and prospects

    Science.gov (United States)

    Barrière, Nicolas M.; Tomsick, John A.; Ackermann, Marcelo D.; Bastie, Pierre; Boggs, Steven E.; Hanlon, Lorraine; Jentschel, Michael; Lowell, Alexander; Roudil, Gilles; von Ballmoos, Peter; Wade, Colin

    2013-09-01

    We report on the status of the Laue lens development effort led by UC Berkeley, where a dedicated X-ray beamline and a Laue lens assembly station were built. This allowed the realization of a first lens prototype in June 2012. Based on this achievement, and thanks to a new NASA APRA grant, we are moving forward to enable Laue lenses. Several parallel activities are in progress. Firstly, we are refining the method to glue quickly and accurately crystals on a lens substrate. Secondly, we are conducting a study of high-Z crystals to diffract energies up to 900 keV efficiently. And thirdly, we are exploring new concepts of Si-based lenses that could further improve the focusing capabilities, and thus the sensitivity of Laue lenses.

  3. A 3D printed helical antenna with integrated lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2015-10-26

    A novel antenna configuration comprising a helical antenna with an integrated lens is demonstrated in this work. The antenna is manufactured by a unique combination of 3D printing of plastic material (ABS) and inkjet printing of silver nano-particle based metallic ink. The integration of lens enhances the gain by around 7 dB giving a peak gain of about 16.4 dBi at 9.4 GHz. The helical antenna operates in the end-fire mode and radiates a left-hand circularly polarized (LHCP) pattern. The 3-dB axial ratio (AR) bandwidth of the antenna with lens is 3.2 %. Due to integration of lens and fully printed processing, this antenna configuration offers high gain performance and requires low cost for manufacturing.

  4. Tunable Focus Liquid Lens with Radial-Patterned Electrode

    Directory of Open Access Journals (Sweden)

    Miao Xu

    2015-08-01

    Full Text Available A dielectric liquid lens is prepared based on our previous work. By optimizing the device structure, the liquid lens presents a converging focus with good resolution and changes its focal length over a broad range with a low driving voltage. For a liquid lens with ~2.3 mm diameter in the relaxed state, it can resolve ~40 lp/mm. The resolution does not degrade during focus change. Its focal length can be varied from ~12 to ~5 mm when the applied voltage is changed from 0 to 28 Vrms. The response time of one cycle is ~2.5 s. Our liquid lens, with a low driving voltage for a large dynamic range, has potential applications in imaging, biometrics, optoelectronic, and lab-on-chip devices.

  5. SIMION, Electrostatic Lens Analysis and Design

    International Nuclear Information System (INIS)

    Dahl, David A.

    2001-01-01

    1 - Description of program or function: SIMION is an electrostatic lens analysis and design program. In SIMION an electrostatic lens is defined as a two-dimensional electrostatic potential array containing both electrode and non-electrode points. The potential array is refined using over-relaxation methods allowing voltage contours and ion trajectories to be computed and plotted. Planar and cylindrical symmetry assumptions allow the two-dimensional fields to support three-dimensional ion trajectory calculations. In addition, the user has the option of writing simple programs which can among other actions control field scale factors, dynamically adjust electrodes, and define explicit three-dimensional field functions (e.g. a quadrupole) used in lieu of array fields in specified portions of the potential array. Magnetic fields can be specified for computing ion trajectories in many electrostatic and magnetic field environments. An interactive graphics interface that uses a high resolution color display and mouse allows the user to view electrodes, trajectories, and contours on the screen prior to plotting, and a memory zoom feature permits expansion of selected areas in the current view. The mouse can be operated to edit the potential array, initialize voltage gradients, or resize the potential array. 2 - Method of solution: SIMION is designed to model the electrostatic fields and forces created by a collection of shaped electrodes given certain symmetry assumptions. The electrostatic fields are modeled as boundary value problem solutions of a Laplace elliptical partial differential equation. A finite difference technique called dynamically self-adjusting over-relaxation is applied to the two-dimensional potential array of points representing electrode and non-electrode regions to obtain a best estimate of the voltages for those points within the array that depict non-electrode regions. A standard fourth-order Runge-Kutta method is used for numerical integration of

  6. Acanthamoeba corneal infection in a contact lens wearer.

    Science.gov (United States)

    Logar, J; Kraut, A

    1997-11-01

    Corneal infections cause by micro-organisms are the most serious complications of wearing contact lenses. The paper presents the first case of contact lens-associated keratitis caused by the protozoon Acanthamoeba sp. identified in Slovenia so far. The identification of Acanthamoeba as a cause of keratitis in a soft contact lens wearer alerted us to the fact that this health issue should be given more attention in the future.

  7. Analysis and synthesis of supershaped dielectric lens antennas

    OpenAIRE

    Bia, Pietro; Caratelli, Diego; Mescia, Luciano; Gielis, Johan

    2015-01-01

    Abstract: A novel class of supershaped dielectric lens antennas, whose geometry is described by the three-dimensional (3D) Gielis formula, is introduced and analysed. To this end, a hybrid modelling approach based on geometrical and physical optics is adopted in order to efficiently analyse the multiple wave reflections occurring within the lens and to evaluate the relevant impact on the radiation properties of the antenna under analysis. The developed modelling procedure has been validated b...

  8. Lens dislocation has a possible relationship with laser iridotomy

    OpenAIRE

    Mutoh, Tetsuya; Barrette, Kevin F; Matsumoto, Yukihiro; Chikuda, Makoto

    2012-01-01

    Tetsuya Mutoh,1,2 Kevin F Barrette,2 Yukihiro Matsumoto,1 Makoto Chikuda11Department of Ophthalmology, Dokkyo Medical University Koshigaya Hospital, Koshigaya City, Saitama, Japan; 2Department of Ophthalmology, Boston University School of Medicine, Boston, MA, USAAbstract: We report our recent experience of four eyes with spontaneous lens dislocation in four patients with no history of trauma or any systemic disease associated with zonular dialysis. Lens dislocation developed with 0.5 to 6 mo...

  9. A bandage contact lens prevents extrusion of ocular contents.

    Science.gov (United States)

    Ramjiani, Vipul; Fearnley, Thomas; Tan, Jennifer

    2016-02-01

    A 76 year old male presents with a corneal perforation in a phthisical eye. Definitive treatment in the form of an evisceration was delayed by 38 days. During this period a bandage contact lens prevented extrusion of ocular contents through an enlarging corneal perforation. This case demonstrates that a bandage contact lens can be effective in the immediate management of large corneal perforations whilst awaiting urgent definitive treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Delayed diagnosis of homocystinuria presenting as bilateral congenital lens subluxation

    OpenAIRE

    Jelić-Vuković Marija; Matić Suzana; Barać Josip; Novinščak Tomislav; Belovari Mirna; Barić Hrvoje

    2017-01-01

    Introduction. Homocystinuria is an autosomal recessively inherited defect leading to hyperhomocysteinemia and associated with ocular manifestations, mainly myopia and ectopia lentis. Case outline. A 26-year-old male with secondary glaucoma due to bilateral lens subluxation was admitted to the Department of vitreoretinal surgery. Horizontal nystagmus, bilateral lens subluxation, and bilateral amblyopia were first discovered at the age of three years. Preoperative laboratory workup revealed ele...

  11. Detector LENS as a new tool for solar neutrino spectroscopy

    International Nuclear Information System (INIS)

    Kornoukhov, V.N.

    2001-01-01

    LENS detector is a low-threshold, electron-flavor specific detector for real time measurement of the solar neutrino spectrum at low energies. It is expected that 20 tons of Yb used as a neutrino target should give several hundred events per year. The basic method for implementation of the LENS detector is scintillator technique, namely a liquid scintillator doped (up to 10% in mass) with natural Yb

  12. Signal-enhancement reflective pulse oximeter with Fresnel lens

    Science.gov (United States)

    Chung, Shuang-Chao; Sun, Ching-Cherng

    2016-09-01

    In this paper, a new reflective pulse oximeter is proposed and demonstrated with implanting a Fresnel lens, which enhances the reflected signal. An optical simulation model incorporated with human skin characteristics is presented to evaluate the capability of the Fresnel lens. In addition, the distance between the light emitting diode and the photodiode is optimized. Compared with the other reflective oximeters, the reflected signal light detected by the photodiode is enhanced to more than 140%.

  13. Resistance force for intraocular lens insertion through lens cartridges and syringe-type injectors.

    Science.gov (United States)

    Usui, Masahiko; Tanaka, Takao

    2015-08-01

    To measure and compare the resistance force for intraocular lens (IOL) insertion using 5 syringe-type injector systems. Tokyo Medical University and laboratory in Kowa Co., Tokyo, Japan. Experimental study. Intraocular lenses were inserted into the lens capsular bag of porcine eyes after phacoemulsification using 5 implantation systems (Groups A, B, C, D, and E). For each system, the resistance force for IOL insertion to the lens capsular bag of porcine eyes was measured using an automated force gauge system. For control, the resistance force for IOL delivery into a plastic dish was measured. Changes in the resistance force and its curve and maximum value were evaluated. The mean total area under the curve (AUC) was compared. Data were statistically analyzed. For all groups, the mean resistance forces were 17.2, 6.3, 4.2, 20.7, and 2.3 newtons (N), respectively, in porcine eyes, and 14.4, 5.8, 4.5, 12.6, and 2.2 N in controls. The mean sizes of the total AUC were 43 371, 8465, 6771, 30 306, and 2334 pixels in porcine eyes and 40 940, 7080, 6876, 20 710, and 2215 pixels in controls; the correlation coefficients between the resistance forces and the sizes of the total area were 0.576, 0.113, 0.346, 0.726, and 0.933 in porcine eyes and 0.707, 0.557, 0.914, 0.951, and 0.893 in controls. Resistance force and its curve were clarified in 5 IOL implantation systems. Appropriate IOL and injector selection may be achieved after clarifying resistance force and its waveform during IOL insertion. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015. Published by Elsevier Inc.

  14. Orientation of Phoenician Temples

    Science.gov (United States)

    Escacena Carrasco, José Luis

    The orientation of Phoenician temples has revealed some of the astronomical knowledge of their builders. What we now know on this topic is complemented by other archaeological documents from Syrio-Palestinian cities and their colonies. The astral aspects of Phoenician religion are a direct legacy from the Canaanite traditions 1,000 years earlier and display connections with Mesopotamia and Egypt.

  15. Component-oriented programming

    NARCIS (Netherlands)

    Bosch, J; Szyperski, C; Weck, W; Buschmann, F; Buchmann, AP; Cilia, MA

    2003-01-01

    This report covers the eighth Workshop on Component-Oriented Programming (WCOP). WCOP has been affiliated with ECOOP since its inception in 1996. The report summarizes the contributions made by authors of accepted position papers as well as those made by all attendees of the workshop sessions.

  16. QUANTIFYING WILDLIFE ORIENTATION

    African Journals Online (AJOL)

    environment (P);. Attitudes expressed towards the natural environment (A);. Activity, or the involvement of a person in conservation actions in the broader sense {I). Different combinations of these functions give rise to four typologies of orientation. (Newgard et al., 1986) in the following way: TYPOLOGY. CHARACTERISTICS.

  17. Social Workers’ Orientation Toward

    NARCIS (Netherlands)

    Deirdre Beneken genaamd Kolmer; René Schalk; Renske J.M. van der Zwet

    2014-01-01

    Objectives: This study assesses social workers’ orientation toward the evidence-based practice (EBP) process and explores which specific variables (e.g. age) are associated. Methods: Data were collected from 341 Dutch social workers through an online survey which included a Dutch translation of the

  18. Cranial irradiation in acute leukemia: dose estimate in the lens

    International Nuclear Information System (INIS)

    Kline, R.W.; Gillin, M.T.; Kun, L.E.

    1979-01-01

    Cranial irradiation for subclinical arachnoid infiltration is standard treatment in childhood acute lymphocytic leukemia. The incidental dose received by the ocular lens is of potential importance since these children evidence a significant long-term survival rate. Comparison of the lens dose using 6MV and 4MV photon beams and a cobalt unit is presented in terms of ion chamber measurements in a water phantom and thermo-luminescent dosimetry (TLD) measurements in a head phantom. TLD measurements on patients treated for acute lymphocytic leukemia (ALL) are examined and used to estimate the dose to the lens. It is demonstrated that the dose to the lens depends strongly on the choice of field margin and on the daily patient set-up. However, using parallel opposed beams in a clinically determined optimal set-up, the dose to the lens is approximately 20 to 30% of the midline central axis dose. By angling the treatment head to eliminate the geometrical divergence of the beam, it is possible to reduce the lens dose to approximately 15% of the midline dose

  19. Spatial distribution of glycerophospholipids in the ocular lens.

    Directory of Open Access Journals (Sweden)

    Jaroslav Pól

    Full Text Available Knowledge of the spatial distribution of lipids in the intraocular lens is important for understanding the physiology and biochemistry of this unique tissue and for gaining a better insight into the mechanisms underlying diseases of the lens. Following our previous study showing the spatial distribution of sphingolipids in the porcine lens, the current study used ultra performance liquid chromatography quadrupole time-of-flight mass spectrometry (UPLC-QTOFMS to provide the whole lipidome of porcine lens and these studies were supplemented by matrix-assisted laser desorption ionization mass spectrometry imaging (MALDI MSI of the lens using ultra-high resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS to determine the spatial distribution of glycerophospholipids. Altogether 172 lipid species were identified with high confidence and their concentration was determined. Sphingomyelins, phosphatidylcholines, and phosphatidylethanolamines were the most abundant lipid classes. We then determined the spatial and concentration-dependent distributions of 20 phosphatidylcholines, 6 phosphatidylethanolamines, and 4 phosphatidic acids. Based on the planar molecular images of the lipids, we report the organization of fiber cell membranes within the ocular lens and suggest roles for these lipids in normal and diseased lenses.

  20. Flat Lens Focusing Demonstrated With Left-Handed Metamaterial

    Science.gov (United States)

    Wilson, Jeffrey D.; Schwartz, Zachary D.; Chevalier, Christine T.; Downey, Alan N.; Vaden, Karl R.

    2004-01-01

    Left-handed metamaterials (LHM's) are a new media engineered to possess an effective negative index of refraction over a selected frequency range. This characteristic enables LHM's to exhibit physical properties never before observed. In particular, a negative index of refraction should cause electromagnetic radiation to refract or bend at a negative angle when entering an LHM, as shown in the figure above on the left. The figure on the right shows that this property could be used to bring radiation to a focus with a flat LHM lens. The advantage of a flat lens in comparison to a conventional curved lens is that the focal length could be varied simply by adjusting the distance between the lens and the electromagnetic wave source. In this in-house work, researchers at the NASA Glenn Research Center developed a computational model for LHM's with the three-dimensional electromagnetic commercial code Microwave Studio, constructed an LHM flat lens, and used it to experimentally demonstrate the reversed refraction and flat lens focusing of microwave radiation.

  1. Geometry-invariant GRIN lens: iso-dispersive contours

    Science.gov (United States)

    Bahrami, Mehdi; Goncharov, Alexander V.

    2012-01-01

    A dispersive model of a gradient refractive index (GRIN) lens is introduced based on the idea of iso-dispersive contours. These contours have constant Abbe number and their shape is related to iso-indicial contours of the monochromatic geometry-invariant GRIN lens (GIGL) model. The chromatic GIGL model predicts the dispersion throughout the GRIN structure by using the dispersion curves of the surface and the center of the lens. The analytical approach for paraxial ray tracing and the monochromatic aberration calculations used in the GIGL model is employed here to derive closed-form expressions for the axial and lateral color coefficients of the lens. Expressions for equivalent refractive index and the equivalent Abbe number of the homogeneous equivalent lens are also presented and new aspects of the chromatic aberration change due to aging are discussed. The key derivations and explanations of the GRIN lens optical properties are accompanied with numerical examples for the human and animal eye GRIN lenses. PMID:22808438

  2. The pupil can control an artificial lens intuitively.

    Science.gov (United States)

    Fliedner, Jan; Heine, Christian; Bretthauer, Georg; Wilhelm, Helmut

    2014-02-04

    After cataract surgery, the ability to accommodate is lost. For this reason, a mechatronic IOL is being developed at the moment: The Artificial Accommodation System. This device requires an easily measureable indicator of the distance of the observed object to determine the demand of accommodation. As the pupil constricts with near vision, pupil size might be such an indicator. Our research focused on whether the pupil can control an artificial lens. A study with 14 healthy subjects aged between 24 and 64 years was conducted. An artificial lens with variable refractive power was mounted in front of one eye. In this eye, natural accommodation was greatly reduced or absent due to presbyopia, pseudophakia, or iatrogenic cycloplegia. The lens' refractive power was changed in a computer-controlled manner depending on changes in the pupil diameter of the second eye, which could not see the fixation stimulus. The subject's task was to get a clear focused image of the target in different distances. The lens can be controlled by the pupil intuitively (P < 1.8 × 10(-18)). Without prior knowledge, 11/14 subjects passed the first trial, and 31/41 trials were successful. Only one subject was not able to control the lens at all. Most subjects comprehended instantly how to use the unfamiliar lens control to bring a target into focus. This study emphasizes the plasticity of the visual control system. Positioning accuracy was acceptable, but the control must be optimized to facilitate maintaining a defined refractive power.

  3. Adaptive neuro-fuzzy estimation of optimal lens system parameters

    Science.gov (United States)

    Petković, Dalibor; Pavlović, Nenad T.; Shamshirband, Shahaboddin; Mat Kiah, Miss Laiha; Badrul Anuar, Nor; Idna Idris, Mohd Yamani

    2014-04-01

    Due to the popularization of digital technology, the demand for high-quality digital products has become critical. The quantitative assessment of image quality is an important consideration in any type of imaging system. Therefore, developing a design that combines the requirements of good image quality is desirable. Lens system design represents a crucial factor for good image quality. Optimization procedure is the main part of the lens system design methodology. Lens system optimization is a complex non-linear optimization task, often with intricate physical constraints, for which there is no analytical solutions. Therefore lens system design provides ideal problems for intelligent optimization algorithms. There are many tools which can be used to measure optical performance. One very useful tool is the spot diagram. The spot diagram gives an indication of the image of a point object. In this paper, one optimization criterion for lens system, the spot size radius, is considered. This paper presents new lens optimization methods based on adaptive neuro-fuzzy inference strategy (ANFIS). This intelligent estimator is implemented using Matlab/Simulink and the performances are investigated.

  4. Innovative light collimator with afocal lens and total internal reflection lens for daylighting system.

    Science.gov (United States)

    Chen, Bo-Jian; Chen, Yin-Ti; Ullah, Irfan; Chou, Chun-Han; Chan, Kai-Cyuan; Lai, Yi-Lung; Lin, Chia-Ming; Chang, Cheng-Ming; Whang, Allen Jong-Woei

    2015-10-01

    This research presents a novel design of the collimator, which uses total internal reflection (TIR), convex, and concave lenses for the natural light illumination system (NLIS). The concept of the NLIS is to illuminate building interiors with natural light, which saves energy consumption. The TIR lens is used to collimate the light, and convex and concave lenses are used to converge the light to the required area. The results have shown that the efficiency in terms of achieving collimated light using the proposed collimator at the output of the light collector is better than that of a previous system without a collimator.

  5. Effects of gamma radiation on rabbit lens

    International Nuclear Information System (INIS)

    Ordahl, J.N.; Gorthy, W.C.

    1982-01-01

    Eyes of young New Zealand white rabbits were irradiated with 2000 rads of gamma radiation ( 60 Co) and the eyes removed at 2, 8, 16, and 30 days post-irradiation for electron microscopic analysis. Lenses were treated histochemically for acid phosphatase localization to examine the role of lysosomal enzymes in the early development of radiation cataracts. Intercellularly located acid phosphatase reaction product, noted in the epithelium and subjacent cortex, was more prevalent after irradiation, especially in central and transitional epithelial zones. In the central zone small vesicles typically were most numerous in areas of extensive intercellular reaction product. The occurrence of discrete packets of reaction product within the vesicles and the adjoining intercellular space, plus the resemblance of the peripheral vesicles to small Golgi vesicles also containing reaction product, suggested an exocytotic release of the enzyme. These appearances suggest that lysosomal hydrolases are released extracellularly by a secretory mechanism accelerated by radiation and that these hydrolases may play a role in both physiological and pathological functions of the lens. (author)

  6. Metasurface Enabled Wide-Angle Fourier Lens.

    Science.gov (United States)

    Liu, Wenwei; Li, Zhancheng; Cheng, Hua; Tang, Chengchun; Li, Junjie; Zhang, Shuang; Chen, Shuqi; Tian, Jianguo

    2018-04-19

    Fourier optics, the principle of using Fourier transformation to understand the functionalities of optical elements, lies at the heart of modern optics, and it has been widely applied to optical information processing, imaging, holography, etc. While a simple thin lens is capable of resolving Fourier components of an arbitrary optical wavefront, its operation is limited to near normal light incidence, i.e., the paraxial approximation, which puts a severe constraint on the resolvable Fourier domain. As a result, high-order Fourier components are lost, resulting in extinction of high-resolution information of an image. Other high numerical aperture Fourier lenses usually suffer from the bulky size and costly designs. Here, a dielectric metasurface consisting of high-aspect-ratio silicon waveguide array is demonstrated experimentally, which is capable of performing 1D Fourier transform for a large incident angle range and a broad operating bandwidth. Thus, the device significantly expands the operational Fourier space, benefitting from the large numerical aperture and negligible angular dispersion at large incident angles. The Fourier metasurface will not only facilitate efficient manipulation of spatial spectrum of free-space optical wavefront, but also be readily integrated into micro-optical platforms due to its compact size. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Exome Array Analysis of Nuclear Lens Opacity.

    Science.gov (United States)

    Loomis, Stephanie J; Klein, Alison P; Lee, Kristine E; Chen, Fei; Bomotti, Samantha; Truitt, Barbara; Iyengar, Sudha K; Klein, Ronald; Klein, Barbara E K; Duggal, Priya

    2018-06-01

    Nuclear cataract is the most common subtype of age-related cataract, the leading cause of blindness worldwide. It results from advanced nuclear sclerosis, or opacity in the center of the optic lens, and is affected by both genetic and environmental risk factors, including smoking. We sought to understand the genetic factors associated with nuclear sclerosis through interrogation of rare and low frequency coding variants using exome array data. We analyzed Illumina Human Exome Array data for 1,488 participants of European ancestry in the Beaver Dam Eye Study who were without cataract surgery for association with nuclear sclerosis grade, controlling for age and sex. We performed single-variant regression analysis for 32,138 variants with minor allele frequency (MAF) ≥0.003. In addition, gene-based analysis of 11,844 genes containing at least two variants with MAF nuclear sclerosis, the possible association with the RNF149 gene highlights a potential candidate gene for future studies that aim to understand the genetic architecture of nuclear sclerosis.

  8. Sutureless Intrascleral Fixated Intraocular Lens Implantation.

    Science.gov (United States)

    Karadag, Remzi; Celik, Haci Ugur; Bayramlar, Huseyin; Rapuano, Christopher J

    2016-08-01

    To review sutureless intrascleral intraocular lens (IOL) fixation methods. Review of published literature. Sutureless intrascleral IOL fixation methods are newer and have been developed to eliminate the suture-related complications of sutured scleral fixation methods such as suture-induced inflammation or infection and IOL dislocation or subluxation due to suture degradation or suture breakage. Sutureless intrascleral fixation methods aim for intrascleral haptic fixation to achieve stability of the IOL. Various methods of sutureless scleral fixation have been described. Using a needle, a blade, or a trochar, sclerostomies are created in all techniques for intraocular access. Some surgeons prefer to create scleral tunnels, whereas others use scleral flaps for scleral fixation of haptics. The stability of IOLs is attained by the scar tissue formed around the haptics. Short-term results of these new methods are acceptable; studies including more cases with longer follow-up are needed to determine their long-term success. [J Cataract Refract Surg. 2016;32(9):586-597.]. Copyright 2016, SLACK Incorporated.

  9. Harm reduction through a social justice lens.

    Science.gov (United States)

    Pauly, Bernadette

    2008-02-01

    People who are street involved such as those experiencing homelessness and drug use face multiple inequities in health and access to health care. Morbidity and mortality are significantly increased among those who are street involved. Incorporation of a harm reduction philosophy in health care has the potential to shift the moral context of health care delivery and enhance access to health care services. However, harm reduction with a primary focus on reducing the harms of drug use fails focus on the harms associated with the context of drug use such as homelessness, violence and poverty. Ethical analysis of the underlying values of harm reduction and examination of different conceptions of justice are discussed as a basis for action that addresses a broad range of harms associated with drug use. Theories of distributive justice that focus primarily on the distribution of material goods are limited as theoretical frameworks for addressing the root causes of harm associated with drug use. Social justice, reconceptualised and interpreted through a critical lens as described by Iris Marion Young, is presented as a promising alternative ethical framework. A critical reinterpretation of social justice leads to insights that can illuminate structural inequities that contribute to the harms associated with the context of drug use. Such an approach provides promise as means of informing policy that aims to reduce a broad range of harms associated with drug use such as homelessness and poverty.

  10. Phacoemulsification using iris hooks and scleral fixation of the intraocular lens in patients with secondary glaucoma associated with lens subluxation.

    Science.gov (United States)

    Ma, K T; Lee, H K; Seong, G J; Kim, C Y

    2008-09-01

    We described the techniques and results of phacoemulsification using iris hook and scleral fixation of intraocular lens (IOL) in patients with secondary glaucoma associated with lens subluxation. Eight eyes of seven patients with secondary glaucoma associated with lens dislocation, who had undergone the surgery, were retrospectively reviewed. At a mean of 23.5 months+/-13.6 (SD) after the surgery, the mean best-corrected visual acuity improved from 0.24+/-0.21 to 0.83+/-0.3, and mean intraocular pressure (IOP) was changed from 38.4+/-11.4 to 15.5+/-1.8 mmHg at the final examination. There were no vitreoretinal complications except cystoid macular oedema in one eye. The technique appears to be safe and effective in terms of visual rehabilitation and controlling IOP in patients with secondary glaucoma associated with lens subluxation.

  11. Calculation of lens alignment errors using the ray transfer matrices for the lens assembly system with an autocollimator and a rotation stage

    Science.gov (United States)

    Chu, Jiyoung; Cho, Sungwhi; Joo, Won Don; Jang, Sangdon

    2017-08-01

    One of the most popular methods for high precision lens assembly of an optical system is using an autocollimator and a rotation stage. Some companies provide software for calculating the state of the lens along with their lens assembly systems, but the calculation algorithms used by the software are unknown. In this paper, we suggest a calculation method for lens alignment errors using ray transfer matrices. Alignment errors resulting from tilting and decentering of a lens element can be calculated from the tilts of the front and back surfaces of the lens. The tilt of each surface can be obtained from the position of the reticle image on the CCD camera of the autocollimator. Rays from a reticle of the autocollimator are reflected from the target surface of the lens, which rotates with the rotation stage, and are imaged on the CCD camera. To obtain a clear image, the distance between the autocollimator and the first lens surface should be adjusted according to the focusing lens of the autocollimator and the lens surfaces from the first to the target surface. Ray propagations for the autocollimator and the tilted lens surfaces can be expressed effectively by using ray transfer matrices and lens alignment errors can be derived from them. This method was compared with Zemax simulation for various lenses with spherical or flat surfaces and the error was less than a few percent.

  12. A role for smoothened during murine lens and cornea development.

    Directory of Open Access Journals (Sweden)

    Janet J Y Choi

    Full Text Available Various studies suggest that Hedgehog (Hh signalling plays roles in human and zebrafish ocular development. Recent studies (Kerr et al., Invest Ophthalmol Vis Sci. 2012; 53, 3316-30 showed that conditionally activating Hh signals promotes murine lens epithelial cell proliferation and disrupts fibre differentiation. In this study we examined the expression of the Hh pathway and the requirement for the Smoothened gene in murine lens development. Expression of Hh pathway components in developing lens was examined by RT-PCR, immunofluorescence and in situ hybridisation. The requirement of Smo in lens development was determined by conditional loss-of-function mutations, using LeCre and MLR10 Cre transgenic mice. The phenotype of mutant mice was examined by immunofluorescence for various markers of cell cycle, lens and cornea differentiation. Hh pathway components (Ptch1, Smo, Gli2, Gli3 were detected in lens epithelium from E12.5. Gli2 was particularly localised to mitotic nuclei and, at E13.5, Gli3 exhibited a shift from cytosol to nucleus, suggesting distinct roles for these transcription factors. Conditional deletion of Smo, from ∼E12.5 (MLR10 Cre did not affect ocular development, whereas deletion from ∼E9.5 (LeCre resulted in lens and corneal defects from E14.5. Mutant lenses were smaller and showed normal expression of p57Kip2, c-Maf, E-cadherin and Pax6, reduced expression of FoxE3 and Ptch1 and decreased nuclear Hes1. There was normal G1-S phase but decreased G2-M phase transition at E16.5 and epithelial cell death from E14.5-E16.5. Mutant corneas were thicker due to aberrant migration of Nrp2+ cells from the extraocular mesenchyme, resulting in delayed corneal endothelial but normal epithelial differentiation. These results indicate the Hh pathway is required during a discrete period (E9.5-E12.5 in lens development to regulate lens epithelial cell proliferation, survival and FoxE3 expression. Defective corneal development occurs

  13. A role for smoothened during murine lens and cornea development.

    Science.gov (United States)

    Choi, Janet J Y; Ting, Chao-Tung; Trogrlic, Lidia; Milevski, Stefan V; Familari, Mary; Martinez, Gemma; de Iongh, Robb U

    2014-01-01

    Various studies suggest that Hedgehog (Hh) signalling plays roles in human and zebrafish ocular development. Recent studies (Kerr et al., Invest Ophthalmol Vis Sci. 2012; 53, 3316-30) showed that conditionally activating Hh signals promotes murine lens epithelial cell proliferation and disrupts fibre differentiation. In this study we examined the expression of the Hh pathway and the requirement for the Smoothened gene in murine lens development. Expression of Hh pathway components in developing lens was examined by RT-PCR, immunofluorescence and in situ hybridisation. The requirement of Smo in lens development was determined by conditional loss-of-function mutations, using LeCre and MLR10 Cre transgenic mice. The phenotype of mutant mice was examined by immunofluorescence for various markers of cell cycle, lens and cornea differentiation. Hh pathway components (Ptch1, Smo, Gli2, Gli3) were detected in lens epithelium from E12.5. Gli2 was particularly localised to mitotic nuclei and, at E13.5, Gli3 exhibited a shift from cytosol to nucleus, suggesting distinct roles for these transcription factors. Conditional deletion of Smo, from ∼E12.5 (MLR10 Cre) did not affect ocular development, whereas deletion from ∼E9.5 (LeCre) resulted in lens and corneal defects from E14.5. Mutant lenses were smaller and showed normal expression of p57Kip2, c-Maf, E-cadherin and Pax6, reduced expression of FoxE3 and Ptch1 and decreased nuclear Hes1. There was normal G1-S phase but decreased G2-M phase transition at E16.5 and epithelial cell death from E14.5-E16.5. Mutant corneas were thicker due to aberrant migration of Nrp2+ cells from the extraocular mesenchyme, resulting in delayed corneal endothelial but normal epithelial differentiation. These results indicate the Hh pathway is required during a discrete period (E9.5-E12.5) in lens development to regulate lens epithelial cell proliferation, survival and FoxE3 expression. Defective corneal development occurs secondary to defects

  14. Value oriented strategic marketing

    Directory of Open Access Journals (Sweden)

    Milisavljević Momčilo

    2013-01-01

    Full Text Available Changes in today's business environment require companies to orient to strategic marketing. The company accepting strategic marketing has a proactive approach and focus on continuous review and reappraisal of existing and seeking new strategic business areas. Difficulties in achieving target profit and growth require turning marketing from the dominant viewpoint of the tangible product to creating superior value and developing relationships with customers. Value orientation implies gaining competitive advantage through continuous research and understanding of what value represents to the consumers and discovering new ways to meet their required values. Strategic marketing investment requires that the investment in the creation of values should be regularly reviewed in order to ensure a focus on customers with high profit potential and environmental value. This increases customer satisfaction and retention and long-term return on investment of companies.

  15. Electrodynamics and Time Orientability

    Science.gov (United States)

    Hadley, Mark J.

    2017-06-01

    On spacetimes that are not time orientable we construct a U(1) bundle to measure the twisting of the time axis. This single assumption, and simple construction, gives rise to Maxwell's equations of electromagnetism, the Lorentz force law and the Einstein-Maxwell equations for electromagnetism coupled to General relativity. The derivations follow the Kaluza Klein theory, but with the constraints required for connections on a U(1) bundle rather than five spacetime dimensions. The non time orientability is seen to justify and constrain Kaluza Klein theories exactly as required to unify gravitation with electromagnetism. Unlike any other schemes, apparent net electric charges arise naturally because the direction of the electric field reverses along a time reversing path. The boundary of a time reversing region can therefore have a net electric flux and appear exactly as a region containing an electric charge. The treatment is purely classical, but motivated by links between acausal structures and quantum theory.

  16. Chitah: Strong-gravitational-lens hunter in imaging surveys

    Energy Technology Data Exchange (ETDEWEB)

    Chan, James H. H.; Suyu, Sherry H.; Chiueh, Tzihong; More, Anupreeta; Marshall, Philip J.; Coupon, Jean; Oguri, Masamune; Price, Paul

    2015-07-07

    Strong gravitationally lensed quasars provide powerful means to study galaxy evolution and cosmology. Current and upcoming imaging surveys will contain thousands of new lensed quasars, augmenting the existing sample by at least two orders of magnitude. To find such lens systems, we built a robot, Chitah, that hunts for lensed quasars by modeling the configuration of the multiple quasar images. Specifically, given an image of an object that might be a lensed quasar, Chitah first disentangles the light from the supposed lens galaxy and the light from the multiple quasar images based on color information. A simple rule is designed to categorize the given object as a potential four-image (quad) or two-image (double) lensed quasar system. The configuration of the identified quasar images is subsequently modeled to classify whether the object is a lensed quasar system. We test the performance of Chitah using simulated lens systems based on the Canada–France–Hawaii Telescope Legacy Survey. For bright quads with large image separations (with Einstein radius ${r}_{\\mathrm{ein}}\\gt 1\\buildrel{\\prime\\prime}\\over{.} 1$) simulated using Gaussian point-spread functions, a high true-positive rate (TPR) of $\\sim 90\\%$ and a low false-positive rate of $\\sim 3\\%$ show that this is a promising approach to search for new lens systems. We obtain high TPR for lens systems with ${r}_{\\mathrm{ein}}\\gtrsim 0\\buildrel{\\prime\\prime}\\over{.} 5$, so the performance of Chitah is set by the seeing. We further feed a known gravitational lens system, COSMOS 5921+0638, to Chitah, and demonstrate that Chitah is able to classify this real gravitational lens system successfully. Our newly built Chitah is omnivorous and can hunt in any ground-based imaging surveys.

  17. How Could Contact Lens Wearers Be at Risk of Acanthamoeba Infection? A Review

    Directory of Open Access Journals (Sweden)

    Youhanna W. Ibrahim

    2009-01-01

    Full Text Available Contact lens wear is highly influential on the incidence of ulcerative keratitis worldwide, particularly in developed countries. The association between Acanthamoeba keratitis and contact lens wear is firmly established; it may account for up to 95% of the reported cases. Before the popularisation of soft contact lens wear, Acanthamoeba keratitis was extremely rare. In 2000 it was estimated that the number of contact lens wearers worldwide was about 80 million, out of whom 33 million were in the United States and 90% of them wore hydrogel soft lenses. Contact lens-related problems depend on many factors, such as lens material, wearing modality, lens hygiene, type of lens-caring solution, the degree of compliance of the lens user with lens wear and care procedures, lens overwear, sleeping in lenses, rate of changing lenses, and lens case hygiene. This paper is a thorough review of the literature aiming to highlight the role of one of the main risk factors of infectious keratitis, contact lens wear, and also to show the responsibility of lens users in aggravating this risk.

  18. Novel fabrication technique of hybrid structure lens array for 3D images

    Science.gov (United States)

    Lee, Junsik; Kim, Junoh; Kim, Cheoljoong; Shin, Dooseub; Koo, Gyohyun; Won, Yong Hyub

    2016-03-01

    Tunable liquid lens arrays can produce three dimensional images by using electrowetting principle that alters surface tensions by applying voltage. This method has advantages of fast response time and low power consumption. However, it is challenging to fabricate a high fill factor liquid lens array and operate three dimensional images which demand high diopter. This study describes a hybrid structure lens array which has not only a liquid lens array but a solid lens array. A concave-shape lens array is unavoidable when using only the liquid lens array and some voltages are needed to make the lens flat. By placing the solid lens array on the liquid lens array, initial diopter can be positive. To fabricate the hybrid structure lens array, a conventional lithographic process in semiconductor manufacturing is needed. A negative photoresist SU-8 was used as chamber master molds. PDMS and UV adhesive replica molding are done sequentially. Two immiscible liquids, DI water and dodecane, are injected in the fabricated chamber, followed by sealing. The fabricated structure has a 20 by 20 pattern of cylindrical shaped circle array and the aperture size of each lens is 1mm. The thickness of the overall hybrid structure is about 2.8mm. Hybrid structure lens array has many advantages. Solid lens array has almost 100% fill factor and allow high efficiency. Diopter can be increased by more than 200 and negative diopter can be shifted to the positive region. This experiment showed several properties of the hybrid structure and demonstrated its superiority.

  19. AEGIS: Agent Oriented Organisations

    OpenAIRE

    Unland, R.; Kirn, S.; Wanka, U.; O'Hare, G. M. P. (Greg M. P.); Abbas, S.

    1995-01-01

    Today's enterprises are faced with highly dynamic, sometimes even hostile environments. This paper dicovers that the two most prominent organizational strategies addressing these challenges, namely that of widespread decentralization and of business process orientation, are inherently conflicting. We argue that cooperative knowledge processing technology can contribute to dissolve this conflict. For this purpose, we introduce the reader into the field of Distributed Artificial Intelligence. O...

  20. Cerro Largo South orientation

    International Nuclear Information System (INIS)

    Pradier, B.

    1982-01-01

    This work is about Cerro Largo South orientation. The site is located in the northeast of Uruguay in the south of Melo city, Department of Cerro Largo. The study was carried out in the young edge socket in the East side of a small valley. This metamorphic socket constituted by gneisses and crystalline limestone are in contact with upper carboniferous formations and basal deposits composed by sandstones and conglomerates

  1. Aspect-Oriented Programming

    Science.gov (United States)

    Elrad, Tzilla (Editor); Filman, Robert E. (Editor); Bader, Atef (Editor)

    2001-01-01

    Computer science has experienced an evolution in programming languages and systems from the crude assembly and machine codes of the earliest computers through concepts such as formula translation, procedural programming, structured programming, functional programming, logic programming, and programming with abstract data types. Each of these steps in programming technology has advanced our ability to achieve clear separation of concerns at the source code level. Currently, the dominant programming paradigm is object-oriented programming - the idea that one builds a software system by decomposing a problem into objects and then writing the code of those objects. Such objects abstract together behavior and data into a single conceptual and physical entity. Object-orientation is reflected in the entire spectrum of current software development methodologies and tools - we have OO methodologies, analysis and design tools, and OO programming languages. Writing complex applications such as graphical user interfaces, operating systems, and distributed applications while maintaining comprehensible source code has been made possible with OOP. Success at developing simpler systems leads to aspirations for greater complexity. Object orientation is a clever idea, but has certain limitations. We are now seeing that many requirements do not decompose neatly into behavior centered on a single locus. Object technology has difficulty localizing concerns invoking global constraints and pandemic behaviors, appropriately segregating concerns, and applying domain-specific knowledge. Post-object programming (POP) mechanisms that look to increase the expressiveness of the OO paradigm are a fertile arena for current research. Examples of POP technologies include domain-specific languages, generative programming, generic programming, constraint languages, reflection and metaprogramming, feature-oriented development, views/viewpoints, and asynchronous message brokering. (Czarneclu and

  2. Oriented Fiber Filter Media

    OpenAIRE

    R. Bharadwaj; A. Patel, S. Chokdeepanich, Ph.D.; G.G. Chase, Ph.D.

    2008-01-01

    Coalescing filters are widely used throughout industry and improved performance will reduce droplet emissions and operating costs. Experimental observations show orientation of micro fibers in filter media effect the permeability and the separation efficiency of the filter media. In this work two methods are used to align the fibers to alter the filter structure. The results show that axially aligned fiber media improve quality factor on the order of 20% and cutting media on an angle from a t...

  3. The Lens Staring You in the Face

    Science.gov (United States)

    vachon, R. W.

    2012-12-01

    When you are embedded in the minutia of a science, you and your collaborators don't need to be convinced that there are benefits to investigating your precise science. You are intrinsically invested. In fact, we spend so much time around each other that we create our own language. So many acronyms that we come to take for granted and topic relevant words, like "fractionate", are not common parlance. This is the case with any specialization, but when it becomes second nature to communicate your work with these norms, transmission breaks down, people tune out, and some audiences become frustrated. Media can cushion this separation, but what do you do when you are the one in front of the camera, and clarity and impact of a concept rests on your shoulders? Just as writing a peer review paper is an acquired skill, so is communicating to the ones who pay many of our salaries, taxpayers. Over the past three years I have worked intimately with publishers, networks and university outreach programs to refine my approach to communicating scientific knowledge to particular audiences. The road has positioned me as interviewee, motivational speaker for science, technology, engineering and math (STEM) in middle and high schools, and educational video series host. Media has their own standards. Personality and enthusiasm may be just as important as the journal into which your findings were published. This presentation will emphasize the audience-adjustable tenants that have stood the test of time to result in effective video communication. Additionally, preparation for and execution of different roles in front of the lens will be discussed.Communicating concepts on video

  4. New trends in intraocular lens imaging

    Science.gov (United States)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  5. Understanding voter orientation in the context of political market orientation

    DEFF Research Database (Denmark)

    Ormrod, Robert P.; Henneberg, Stephan C.

    2010-01-01

    modelling to test several hypotheses. While the results show that political parties focus on several different aspects of market-oriented behaviour, especially using an internal and societal orientation as cultural antecedents, a more surprising result is the inconclusive effect of a voter orientation...

  6. Club d'orientation

    CERN Multimedia

    Club d'orientation

    2014-01-01

    Courses d’orientation ce printemps Le Club d’orientation du CERN vous invite à venir découvrir la course d’orientation et vous propose, en partenariat avec d’autres clubs de la région, une dizaine de courses populaires. Celles-ci ont lieu les samedis après-midi, elles sont ouvertes à tous, quel que soit le niveau, du débutant au sportif confirmé, en famille ou en individuel, en promenade ou en course. Si vous êtes débutant vous pouvez profiter d’une petite initiation offerte par l’organisateur avant de vous lancer sur un parcours. Divers types de parcours sont à votre choix lors de chaque épreuve: facile court (2-3 km), facile moyen (3-5 km), technique court (3-4 km), technique moyen (4-5 km) et technique long (5-7 km). Les dates à retenir sont les suivantes pour la coupe genevoise de printemps: Samedi 22 mars: Apples (...

  7. Oriented Poly(dialkylstannane)s

    DEFF Research Database (Denmark)

    Choffat, Fabien; Fornera, Sara; Smith, Paul

    2008-01-01

    The inorganic (or 'organometallic') polymers poly(dibutylstannane), poly(dioctylstannane), and poly(didodecylstannane) have been oriented by shear forces, the tensile drawing of blends with polyethylene, and deposition from solution onto glass slides coated with all oriented, friction...

  8. Non-thermal electromagnetic radiation damage to lens epithelium.

    Science.gov (United States)

    Bormusov, Elvira; P Andley, Usha; Sharon, Naomi; Schächter, Levi; Lahav, Assaf; Dovrat, Ahuva

    2008-05-21

    High frequency microwave electromagnetic radiation from mobile phones and other modern devices has the potential to damage eye tissues, but its effect on the lens epithelium is unknown at present. The objective of this study was to investigate the non-thermal effects of high frequency microwave electromagnetic radiation (1.1GHz, 2.22 mW) on the eye lens epithelium in situ. Bovine lenses were incubated in organ culture at 35°C for 10-15 days. A novel computer-controlled microwave source was used to investigate the effects of microwave radiation on the lenses. 58 lenses were used in this study. The lenses were divided into four groups: (1) Control lenses incubated in organ culture for 10 to15 days. (2) Electromagnetic radiation exposure group treated with 1.1 GHz, 2.22 mW microwave radiation for 90 cycles of 50 minutes irradiation followed by 10 minutes pause and cultured up to 10 days. (3) Electromagnetic radiation exposure group treated as group 2 with 192 cycles of radiation and cultured for 15 days. (4) Lenses exposed to 39.5°C for 2 hours 3 times with 24 hours interval after each treatment beginning on the second day of the culture and cultured for 11 days. During the culture period, lens optical quality was followed daily by a computer-operated scanning laser beam. At the end of the culture period, control and treated lenses were analyzed morphologically and by assessment of the lens epithelial ATPase activity. Exposure to 1.1 GHz, 2.22 mW microwaves caused a reversible decrease in lens optical quality accompanied by irreversible morphological and biochemical damage to the lens epithelial cell layer. The effect of the electromagnetic radiation on the lens epithelium was remarkably different from those of conductive heat. The results of this investigation showed that electromagnetic fields from microwave radiation have a negative impact on the eye lens. The lens damage by electromagnetic fields was distinctly different from that caused by conductive heat.

  9. Development of a Laue lens for nuclear astrophysics

    International Nuclear Information System (INIS)

    Barriere, N.

    2008-04-01

    The Laue lenses we study focuses in the domain of 0.1-1 MeV thanks to Bragg diffraction in the volume of a large number of small crystal tiles. The focal length of a typical Laue lens system is of the order of 100 m. This requirement calls for two formation flying satellites maintaining lens and detector at the focal distance. The major breakthrough of Laue lenses is to decouple collecting area from detector area. Concentrating a signal from the large area of a Laue lens onto a small focal spot dramatically increases the signal over background ratio with respect to present technologies. Here is the reason for the long awaited leap in sensitivity. The objective of the present thesis was to improve the concept, finding viable technical solutions towards a future space mission. Two aspects of the lens development have been highlighted in this thesis: the first one is an analytical model of the lens that is used to calculate and improve the performance of a certain configuration, the second aspect concerns the search and the characterization of diffracting media of interest. The lens model developed relies on a fast semi-analytical simulation library, permitting to build several design- and optimisation-tools. For the configuration of a given lens, this code computes the resulting effective area and point spread function in a handful of seconds. The model helps finding lens configurations (mass, pack ratio of the lens rings,...) which are automatically refined to match with effective area and energy coverage constraints. These tools have been used to investigate various design aspects, such as the influence of focal length, size, mosaic spread, structure and materials of crystals, etc... The central evaluation criterion in the model is a figure of merit, based on the compactness of the focal spot and the intensity of the collected signal. The second part of this work addresses the actual search and characterization of crystals potentially interesting for Laue lenses

  10. The effects of market orientation

    OpenAIRE

    Sandvik, Kåre

    1998-01-01

    This research is designed to accomplish three goals. The first goal is to revisit the market orientation construct in order to define the different facets of it. A review of the market orientation literature is made to assess and synthesize the stock of accumulated knowledge regarding the market orientation construct. The second goal of the research is to develop a theory of the effects ofmarket orientation. Using the literature concerning resource-based theory and organization...

  11. Nanoceria have no genotoxic effect on human lens epithelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Pierscionek, Barbara K; Yasseen, Akeel A [School of Biomedical Sciences, University of Ulster, Coleraine, BT52 1SA (United Kingdom); Li, Yuebin; Schachar, Ronald A; Chen, Wei [Department of Physics, University of Texas at Arlington, Arlington, TX 76019 (United States); Colhoun, Liza M, E-mail: b.pierscionek@ulster.ac.uk, E-mail: weichen@uta.edu [Centre for Vision and Vascular Sciences, School of Medicine, Dentistry and Biomedical Sciences, Queen' s University Belfast, Grosvenor Road, Belfast, BT12 6BA (United Kingdom)

    2010-01-22

    There are no treatments for reversing or halting cataract, a disease of the structural proteins in the eye lens, that has associations with other age-related degenerative conditions such as Alzheimer's disease. The incidence of cataract and associated conditions is increasing as the average age of the population rises. Protein folding diseases are difficult to assess in vivo as proteins and their age-related changes are assessed after extraction. Nanotechnology can be used to investigate protein changes in the intact lens as well as for a potential means of drug delivery. Nanoparticles, such as cerium oxide (CeO{sub 2}) which have antioxidant properties, may even be used as a means of treating cataract directly. Prior to use in treatments, nanoparticle genotoxicity must be tested to assess the extent of any DNA or chromosomal damage. Sister chromatid exchanges were measured and DNA damage investigated using the alkaline COMET assay on cultured human lens epithelial cells, exposed to 5 and 10 {mu}g ml{sup -1} of CeO{sub 2} nanoparticles (nanoceria). Nanoceria at these dosages did not cause any DNA damage or significant increases in the number of sister chromatid exchanges. The absence of genotoxic effects on lens cells suggests that nanoceria, in the doses and exposures tested in this study, are not deleterious to the eye lens and have the potential for use in studying structural alterations, in developing non-surgical cataract treatments and in investigating other protein folding diseases.

  12. Athermal design and analysis of glass-plastic hybrid lens

    Science.gov (United States)

    Yang, Jian; Cen, Zhaofeng; Li, Xiaotong

    2018-01-01

    With the rapid development of security market, the glass-plastic hybrid lens has gradually become a choice for the special requirements like high imaging quality in a wide temperature range and low cost. The reduction of spherical aberration is achieved by using aspherical surface instead of increasing the number of lenses. Obviously, plastic aspherical lens plays a great role in the cost reduction. However, the hybrid lens has a priority issue, which is the large thermal coefficient of expansion of plastic, causing focus shift and seriously affecting the imaging quality, so the hybrid lens is highly sensitive to the change of temperature. To ensure the system operates normally in a wide temperature range, it is necessary to eliminate the influence of temperature on the hybrid lens system. A practical design method named the Athermal Material Map is summarized and verified by an athermal design example according to the design index. It includes the distribution of optical power and selection of glass or plastic. The design result shows that the optical system has excellent imaging quality at a wide temperature range from -20 ° to 70 °. The method of athermal design in this paper has generality which could apply to optical system with plastic aspherical surface.

  13. Performance evaluation of macro lens in digital close range photogrammetry

    Science.gov (United States)

    Yanagi, H.; Chikatsu, H.

    2009-08-01

    Recently, the documentation and visualization of various cultural heritages have been receiving attention, and a small Buddha such as less than 10 cm tall which was stored in the womb of Buddha is also included in cultural heritages. Zoom lenses are generally used to document these small objects and thus conserve the cultural heritage. However, there exist certain issues pertaining to the use of zoom lenses for such digital documentation. These issues include image sharpness and distortions that occur with changes in focal length setting, and in particular, the depth of field is issue from application standpoint such as documentation of the small cultural heritage. On the other hand, macro lenses can be used to capture sharp images of small objects from the view point of working distance, and its depth of field is related to the aperture of the camera. In order to evaluate the effectiveness of macro lenses in digital close range photogrammetry, macro lens and zoom lens were mounted on a digital single lens reflex camera (Canon EOS20D, 8.2 Mega pixels). This paper deals in a first part with comparative evaluations for both lenses with respect to their lens distortion, imaging mode, and calibration aspects. The results indicated that macro lenses were more suitable for digital close range photogrammetry. Calibration tests are performed to demonstrate the effectiveness and practicability of macro lens in close range photogrammetic applications.

  14. Lens array fabrication method with volume expansion property of PDMS

    Science.gov (United States)

    Jang, WonJae; Kim, Junoh; Lee, Muyoung; Lee, Jooho; Bang, Yousung; Won, Yong Hyub

    2016-03-01

    Conventionally, poly (dimethylsiloxane) lens array is fabricated by replica molding. In this paper, we describe simple method for fabricating lens array with expanding property of PDMS. The PDMS substrate is prepared by spin coating on cleaned glass. After spin coating PDMS, substrate is treated with O2 plasma to promote adhesion between PDMS substrate and photoresist pattern on it. Positive photoresist az-4330 and AZ 430K developer is used for patterning on PDMS. General photolithography process is used to patterning. Then patterned PDMS substrate is dipped to 1- Bromododecane bath. During this process, patterned photoresist work as a barrier and prevent blocked PDMS substrate from reaction with 1-Bromododecane. Unblocked part of PDMS directly react with 1-Bromododecane and results in expanded PDMS volume. The expansion of PDMS is depends on absorbed 1-Bromododecane volume, dipping time and ratio of block to open area. The focal length of lens array is controlled by those PDMS expansion factors. Scale of patterned photoresist determine a diameter of each lens. The expansion occurs symmetrically at center of unblocked PDMS and 1-Bromododecane interface. As a result, the PDMS lens array is achieved by this process.

  15. Plasmonic Luneburg lens antenna synthesized by metasurfaces with hexagonal lattices.

    Science.gov (United States)

    Chen, Kuang Cheng; Yang, Jiun Wen; Yang, Yueh-Chieh; Khin, Chang Fu; Kehn, M Ng Mou

    2017-10-30

    The metasurface lens composing of 2D periodic metallic patches on a grounded dielectric slab possesses several advantages such as being light, low-profile, compact, and also cheap to manufacture. In this paper, a Luneburg lens synthesized by a metasurface and designated for use as a surface wave antenna is proposed. Two types of unit cell will be compared, one whose surface wave modal dispersion varies significantly with the grazing direction and another that does not. In the context of being applied as surface wave antennas, it will be shown that the Luneburg lens synthesized by the latter kind of unit cell provides improved performance as compared to the former. Several aperture sub-efficiencies of the metasurface-based Luneburg-lens antenna shall be used for the characterization of the radiation. A prototype of the designed lens antenna has also been manufactured. Measurement results agree well with theoretical predictions and the efficacy of this device over a fairly wide bandwidth has been experimentally demonstrated.

  16. Determination of dideoxyosone precursors of AGEs in human lens proteins.

    Science.gov (United States)

    Linetsky, Mikhail; Kaid Johar, S R; Meltretter, Jasmin; Padmanabha, Smitha; Parmar, Trilok; Vasavada, Abhay R; Pischetsrieder, Monika; Nagaraj, Ram H

    2011-10-01

    Dideoxyosones (DDOs) are intermediates in the synthesis of advanced glycation endproducts (AGEs), such as pentosidine and glucosepane. Although the formation of pentosidine and glucosepane in the human lens has been firmly established, the formation of DDOs has not been demonstrated. The aim of this study was to develop a reliable method to detect DDOs in lens proteins. A specific DDO trapping agent, biotinyl-diaminobenzene (3,4-diamino-N-(3-[5-(2-oxohexahydro-1H-thieno[3,4-d]imidazol-4-yl)pentanoyl]aminopropyl)benzamide) (BDAB) was added during in vitro protein glycation or during protein extraction from human lenses. In vitro glycated human lens protein showed strong reaction in monomeric and polymeric crosslinked proteins by Western blot and ELISA. Glycation of BSA in the presence of BDAB resulted in covalent binding of BDAB to the protein and inhibited pentosidine formation. Mass spectrometric analysis of lysozyme glycated in the presence of BDAB showed the presence of quinoxalines at lysine residues at positions K1, K33, K96, and K116. The ELISA results indicated that cataractous lens proteins contain significantly higher levels of DDO than non-cataractous lenses (101.9±67.8 vs. 31.7±19.5AU/mg protein, p<0.0001). This study provides first direct evidence of DDO presence in human tissue proteins and establishes that AGE crosslink synthesis in the human lens occurs via DDO intermediates. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Abnormal patterning analysis using actual lens and illumination source data

    Science.gov (United States)

    Hong, Jongkyun; Lee, Jeonkyu; Kang, Eunsuk; Yang, Hyunjo; Yim, Donggyu; Guerrero, James; Chung, Rob

    2005-05-01

    As the minimum feature size shrinks down, i.e. low K1 lithography regime, the tool"s lens aberration sensitivity and user defined illumination imperfection might play a major role in patterning error. Thus, the study of impact from lens aberration and illumination on patterning is required for good tool maintenance and yield improvement. For this purpose, we collected many cases of abnormal patterning result from production line and then simulated in terms of actual lens aberration and illumination source data. LITEL products of ISI(In-situ Interferometer) and SMI(Source Metrology Interferometer) were used for characterizing lens and illumination source. Moreover, the ACE(Analysis and Characteristic Engine) of LITEL development product was used as the simulator. In this work, deformation of pattern fidelity, for example, CD asymmetry in word line and metal contact layer, pattern bending in isolation layer and also decreasing process window in bit line layer will be discussed with experimental and simulation data. Finally, we are able to make a guideline for preventing abnormal phenomenon. From this study, we can understand which lens aberration terms and illumination imperfection take an effect of abnormal pattering result.

  18. Predicting scleral GP lens entrapped tear layer oxygen tensions.

    Science.gov (United States)

    Jaynes, Jared M; Edrington, Timothy B; Weissman, Barry A

    2015-02-01

    Over the past decade, utilization of scleral gas permeable (GP) contact lenses has steadily increased. Scleral GP lenses offer yet another option for patients suffering from visually debilitating corneal and tear conditions. Oxygen delivery to the cornea in the presence of a contact lens system continues to be a subject of interest, and scleral GP lenses are no exception. This paper utilizes an existing model based on simultaneous two lens systems (piggyback lenses) as a resistance to oxygen in series, and applies this model to scleral GP lens systems. Theoretical oxygen tensions are calculated for tear layers trapped beneath scleral contact lens systems and the anterior corneal surface with a simple single chamber corneal model using a computer software spreadsheet. Only the best case scenario for current scleral gas permeable lenses (thickness and Dk)/tear layer values allow sufficient tear layer oxygen tension (approximately 100 mmHg) to preclude corneal hypoxia. The results of the spreadsheet model suggest that clinicians would be prudent to prescribe scleral GP lenses manufactured in the highest Dk materials available and to fit without excessive corneal clearance to minimize anterior segment hypoxia. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Delayed diagnosis of homocystinuria presenting as bilateral congenital lens subluxation

    Directory of Open Access Journals (Sweden)

    Jelić-Vuković Marija

    2017-01-01

    Full Text Available Introduction. Homocystinuria is an autosomal recessively inherited defect leading to hyperhomocysteinemia and associated with ocular manifestations, mainly myopia and ectopia lentis. Case outline. A 26-year-old male with secondary glaucoma due to bilateral lens subluxation was admitted to the Department of vitreoretinal surgery. Horizontal nystagmus, bilateral lens subluxation, and bilateral amblyopia were first discovered at the age of three years. Preoperative laboratory workup revealed elevated levels of homocysteine. Bilateral pars plana lensectomy and vitrectomy followed by a sulcus fixation of the intraocular lens (ALCON MA60 Acrysof IOL were performed. The patient was prescribed folic acid, methionine, and pyridoxine, and was urged to maintain a methionine-low diet. After a bilateral lensectomy and sulcus fixation of the intraocular lens and a methionine restriction therapy combined with vitamin B6, B9, and B12 supplementation, his condition improved greatly. Conclusion. In this report of a rare case we emphasize the importance of examining differential diagnoses of lens subluxation, since early intervention can prevent serious complications.

  20. Customer loyalty among daily disposable contact lens wearers.

    Science.gov (United States)

    Patel, Neelam I; Naroo, Shehzad A; Eperjesi, Frank; Rumney, Nicholas J

    2015-02-01

    Optometric practices offer contact lenses as cash sale items or as part of monthly payment plans. With the contact lens market becoming increasingly competitive, patients are opting to purchase lenses from supermarkets and Internet suppliers. Monthly payment plans are often implemented to improve loyalty. This study aimed to compare behavioural loyalty between monthly payment plan members and non-members. BBR Optometry Ltd offers a monthly payment plan (Eyelife™) to their contact lens wearers. A retrospective audit of 38 Eyelife™ members (mean±SD: 42.7±15.0 years) and 30 non-members (mean±SD: 40.8±16.7 years) was conducted. Revenue and profits generated, service uptake and product sales between the two groups were compared over a fixed period of 18 months. Eyelife™ members generated significantly higher professional fee revenue (Ployalty among contact lens wearers, particularly service uptake and volume of lens purchases. Additionally the greater professional fees generated, render monthly payment plans an attractive business model and practice builder. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  1. 3D Inkjet Printed Helical Antenna with Integrated Lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-08-30

    The gain of an antenna can be enhanced through the integration of a lens, although this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, through a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB, which provides a peak gain of about 12.9 dBi at 8.8 GHz. The 3-dB axial ratio (AR) bandwidth of the antenna with the lens is 5.5%. This work also reports the complete characterization of this new process in terms of minimum features sizes and achievable conductivities. Due to monolithic integration of the lens through a fully printed process, this antenna configuration offers high gain performance by using a low cost and rapid fabrication technique. © 2016 IEEE.

  2. Repertoire of free-living protozoa in contact lens solutions.

    Science.gov (United States)

    Bouchoucha, Ibtissem; Aziz, Aurore; Hoffart, Louis; Drancourt, Michel

    2016-10-29

    The repertoire of free-living protozoa in contact lens solutions is poorly known despite the fact that such protozoa may act as direct pathogens and may harbor intra-cellular pathogens. Between 2009 and 2014, the contact lens solutions collected from patients presenting at our Ophthalmology Department for clinically suspected keratitis, were cultured on non-nutrient agar examined by microscope for the presence of free-living protozoa. All protozoa were identified by 18S rRNA gene sequencing. A total of 20 of 233 (8.6 %) contact lens solution specimens collected from 16 patients were cultured. Acanthamoeba amoeba in 16 solutions (80 %) collected from 12 patients and Colpoda steini, Cercozoa sp., Protostelium sp. and a eukaryotic more closely related to Vermamoeba sp., were each isolated in one solution. Cercozoa sp., Colpoda sp., Protostelium sp. and Vermamoeba sp. are reported for the first time as contaminating contact lens solutions. The repertoire of protozoa in contact lens solutions is larger than previously known.

  3. Sterility and the disinfection potential of Indian contact lens solutions

    Directory of Open Access Journals (Sweden)

    Gopinathan Usha

    1994-01-01

    Full Text Available Ocular infection associated with microbial contamination of contact lens care products is a major problem in contact lens wearers. The sterility and the antimicrobial activity of contact lens care systems reflect their suitability for disinfection of contact lenses. These factors remain to be evaluated for the various newer contact lens care products manufactured in India. In this study, 35 bottles of contact lens solutions marketed by different manufacturing units in India were tested for sterility. Seven solutions were tested for antimicrobial effectiveness employing the D value method of analysis. The D value is defined as the time required to reduce a population of organisms by 90% (one log unit. A standard inoculum of the ocular isolates of Staphylococcus aureus, Pseudomonas aeruginosa, Serratia marcescens, Aspergillus fumigatus, Fusarium solani, and Acanthamoeba castellanii were used as challenge organisms. Bacterial contamination was detected in 20 (57.1% solution bottles and none yielded fungus or Acanthamoeba. Pseudomonas species were the most commonly encountered contaminant (11/20; 55%. Only sterile solutions were analyzed for antimicrobial activity. D values ranging between 12 and 20 minutes were demonstrated by six of the seven solutions against bacterial challenge. Good antifungal activity was noticed in five solutions against Fusarium solani though results varied with Aspergillus flavus and Candida albicans. All solutions were adequately effective against Acanthamoeba.

  4. Pigment dispersion syndrome associated with spontaneous subluxation of crystalline lens

    Directory of Open Access Journals (Sweden)

    Vikas Veerwal

    2017-01-01

    Full Text Available Pigment dispersion syndrome (PDS is an ocular condition characterized by a dispersion of iris pigment throughout the eye. This pigment is deposited in a characteristic manner on the corneal endothelium as Krukenberg's spindle, anterior surface of the iris, in the trabecular meshwork, on the lens and zonule and occasionally on the anterior hyaloid face. Even with deposition of pigment on zonular fibers, no zonular weakness, or zonular dehiscence has been reported in these cases. We report a unique case of PDS with bilateral spontaneous subluxation of crystalline lens. With characteristic findings of pigment distribution in both his eyes, the patient had concave iris configuration with heavily pigmented trabecular meshwork confirming the diagnosis of PDS. The patient had bilateral 180° temporal subluxation of crystalline lens in both his eyes. The usual cause of lens subluxation such as Marfan's Syndrome and Ehler's Danlos Syndrome was ruled out. The patient underwent right eye followed by left eye intracapsular cataract extraction with ab-interno technique with postoperative best-corrected visual acuity (BCVA of 6/9 in both eyes. Spontaneous subluxation of crystalline lens in isolated PDS is not known to occur and has been reported by means of this case. We recommend a thorough assessment of zonular status in all cases of PDS.

  5. 67P Through the Lens of Art

    Science.gov (United States)

    Smirnova, Ekaterina; ESA, The Open University, OSIRIS

    2016-10-01

    I am an artist, who is deeply inspired by science. Since the landing of the robotic probe Philae on the comet I have been working on an art project called 67P. Having a goal of discovering our place in the universe, I chose ESA's Rosetta mission as a successful example of such discovery. During the conference I'd like to expand the dialogue to include an artistic research of the comet 67P. I invite the participants to explore 67P through the lens of art and create inspirational reciprocity in between two spheres, creative and scientific. New ideas often originate when two vocabularies are smashed together. Via this path we perhaps will be able to get a new way of exploring the topic of cometary science.During the conference I'd like to present:- 67p artwork in the art section- poster outlining the major focuses of my projectArt project focuses:- 67P water:In the art studio I re-create water that is close in composition to the water on the comet, by enriching it with D2O. With this water I paint large scale paintings, based on the photographs by Rosetta (OSIRIS, Nav. Cam.).- spectroscopic data:Inspired by data from OSIRIS, I create an additional layer to my work using augmented reality to reveal a "hidden" from the view layer. I am making a parallel with the idea that some scientific information could be viewed only by using special instruments, in this case - instruments on board of Rosetta spacecraft, such as OSIRIS. You will be able to see a virtual layer on top of my paintings using a readily available instrument - your cellphone. Red, Green and Blue colors, of particular wavelength, will be introduced to the monochromatic paintings.- magnetometer readings:International music collaboration inspired by the "Singing comet" composition, based on the magnetometer data of 67P will be offered for any interested spectators.- 67P smell:In collaboration with The Open University, UK, postcards with a smell of the comet were created, introducing the chemical components of

  6. CTQ 327: A New Gravitational Lens

    Science.gov (United States)

    Morgan, N. D.; Gregg, M. D.; Wisotzki, L.; Becker, R.; Maza, J.; Schechter, P. L.; White, R. L.

    2003-08-01

    We present the second gravitationally lensed quasar discovered during the course of a Hubble Space Telescope Space Telescope Imaging Spectrograph snapshot survey for small-separation gravitational lenses. CTQ 327 is a double quasar with an image separation of 1.22" and a g-band flux ratio of roughly 5 to 1. Spectra reveal both components to be z=1.37 quasars, and the lensing galaxy is clearly visible after point-spread function subtraction of the two quasar components. The light profile of the lensing galaxy is well modeled by an r1/4 law, indicative of an early-type elliptical galaxy. An estimate of the lens galaxy redshift is z~0.4-0.6, based on the Faber-Jackson relationship and photometric considerations, although values outside this range are still consistent with the present data. Resolved spectra of the two quasars show similar, but not identical, continuum and emission-line features: component A exhibits weaker emission lines with respect to the continuum than does component B, and there is evidence of intrinsic differences in the emission-line profiles between the two components. Optical monitoring of the quasar pair also shows a change in the g-band flux ratio of 0.14 mag over a 3 month period. These spectral and photometric differences may be due to microlensing fluctuations from stars in the lensing galaxy, intrinsic quasar variability coupled with the system's differential time delay, or some combination of the two. The observed variability makes CTQ 327 an attractive target for future flux monitoring, aimed at time-delay or microlensing studies. Based on observations obtained with the NASA/ESA Hubble Space Telescope, the W. M. Keck Observatory, and the Magellan Consortium's Walter Baade Telescope. The Space Telescope Science Institute is operated by the Association of Universities for Research in Astronomy (AURA), Inc., under NASA contract NAS 5-26555. The W. M. Keck Observatory is operated as a scientific partnership among the California Institute of

  7. Refractive lens exchange and piggyback intraocular lens implantation in nanophthalmos: Visual and structural outcomes.

    Science.gov (United States)

    Mohebbi, Masoomeh; Fallah-Tafti, Mohammad-Reza; Fadakar, Kaveh; Katoozpour, Ramon; Mohammadi, Seyed-Farzad; Fallah-Tafti, Zahra; Khorami, Azita

    2017-09-01

    To evaluate the best piggyback intraocular lens (IOL) implantation method and the outcomes in nanophthalmos eyes and to define the postoperative structural changes. Farabi Eye Hospital, Tehran, Iran. Prospective case series. Candidates for refractive surgery who were nanophthalmic were recruited. Patients had refractive lens exchange followed by implantation of both IOLs in the bag or 1 IOL in the bag and 1 IOL in the sulcus. The baseline and follow-up visual acuity, refractive status, and structural Scheimpflug imaging were evaluated. Ultrasound biomicroscopy (UBM) was performed 6 months postoperatively. The study comprised 9 nanophthalmic patients (18 eyes) with a mean preoperative uncorrected distance visual acuity (UDVA) of 1.53 logarithm of the minimum angle of resolution (logMAR) ± 0.3 (SD), mean corrected distance visual acuity (CDVA) of 0.34 ± 0.2 logMAR, and mean spherical equivalent (SE) of +13.55 ± 4.0 diopters (D). The mean postoperative UDVA improved from baseline. There was no significant difference in the mean UDVA and CDVA between the 2 IOL groups. Postoperatively, both groups had a significant improvement in SE, a significant rise in anterior chamber depth and angle, and similar UBM measurements. Piggyback IOL implantation was an effective refractive procedure in nanophthalmic eyes. Both implantation methods resulted in similar outcomes; however, the small number of patients in each group made it less likely that possible differences would be found. The increase in angle values might help prevent the development of closed-angle glaucoma. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Sacral orientation and spondylolysis.

    Science.gov (United States)

    Peleg, Smadar; Dar, Gali; Steinberg, Nili; Masharawi, Youssef; Been, Ella; Abbas, Janan; Hershkovitz, Israel

    2009-12-01

    A descriptive study (based on skeletal material) was designed to measure sacral anatomic orientation (SAO) in individuals with and without spondylolysis. To test whether a relationship between SAO and spondylolysis exists. Spondylolysis is a stress fracture in the pars interarticularis (mainly of L5). The natural history of the phenomenon has been debated for years with opinions divided, i.e., is it a developmental condition or a stress fracture phenomenon. There is some evidence to suggest that sacral orientation can be a "key player" in revealing the etiology of spondylolysis. The pelvis was anatomically reconstructed and SAO was measured as the angle created between the intersection of a line running parallel to the superior surface of the sacrum and a line running between the anterior superior iliac spine (ASIS) and the anterior-superior edge of the symphysis pubis (PUBIS).SAO was measured in 99 adult males with spondylolysis and 125 adult males without spondylolysis. The difference between the groups was tested using an unpaired t test. Spondylolysis prevalence is significantly higher in African-Americans compared to European-Americans: 5.4% versus 2.04% in males (P < 0.001) and 2.31% versus 0.4%, P < 0.001 in females. SAO was significantly lower in the spondylolytic group (44.07 degrees +/- 11.46 degrees) compared to the control group (51.07 degrees +/- 8.46 degrees, P < 0.001). A more horizontally oriented sacrum leads to direct impingement on L5 pars interarticularis by both L4 inferior articular facet superiorly and S1 superior articular facet inferiorly. Repetitive stress due to standing (daily activities) or sitting increases the "pincer effect" on this area, and eventually may lead to incomplete synostosis of the neural arch.

  9. Flight calls and orientation

    DEFF Research Database (Denmark)

    Larsen, Ole Næsbye; Andersen, Bent Bach; Kropp, Wibke

    2008-01-01

      In a pilot experiment a European Robin, Erithacus rubecula, expressing migratory restlessness with a stable orientation, was video filmed in the dark with an infrared camera and its directional migratory activity was recorded. The flight overhead of migrating conspecifics uttering nocturnal...... flight calls was simulated by sequential computer controlled activation of five loudspeakers placed in a linear array perpendicular to the bird's migration course. The bird responded to this stimulation by changing its migratory course in the direction of that of the ‘flying conspecifics' but after about...

  10. Mina Oriental report

    International Nuclear Information System (INIS)

    Cicalese, H.; Mari, C.; Lema, F.; Valverde, C.; Haut, R.

    1986-01-01

    This report refers to the obtained results of those geophysical works practiced during the year 1985 in Mina Oriental region, located in the department of Maldonado. The same ones had like object to supplement geophysical studies previous carried out in the area and to investigate a possible connection mineralized in the geologic context with Mina La Esperanza that , where they arose anomalous indications in geochemical prospecting. They were applied the following methods: Induced Polarization, Magnetometry and Electromagnetism. The conclusions and recommendations arrived express one discontinuity among the referred areas, even subtracting some explanations on the detected lateral anomalies.

  11. Emotion-oriented systems

    CERN Document Server

    Pelachaud, Catherine

    2013-01-01

    The Affective Computing domain, term coined by Rosalind Picard in 1997, gathers several scientific areas such as computer science, cognitive science, psychology, design and art. The humane-machine interaction systems are no longer solely fast and efficient. They aim to offer to users affective experiences: user's affective state is detected and considered within the interaction; the system displays affective state; it can reason about their implication to achieve a task or resolve a problem. In this book, we have chosen to cover various domains of research in emotion-oriented systems. Our aim

  12. An integral-field spectroscopic strong lens survey

    Energy Technology Data Exchange (ETDEWEB)

    Bolton, Adam S [Harvard-Smithsonian Center for Astrophysics, 60 Garden St. MS-20, Cambridge, MA 02138 (United States); Burles, Scott [Department of Physics and Kavli Institute, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA 02139 (United States)

    2007-12-15

    We present the observational results of a survey for strong gravitational lens systems consisting of extended emission-line galaxies lensed by intervening early-type galaxies, conducted using integral field units (IFUs) of the Magellan IMACS and Gemini GMOS-N spectrographs. These data are highly valuable for corroborating the lensing interpretation of Hubble Space Telescope imaging data. We show that in many cases, ground-based IFU spectroscopy is in fact competitive with space-based imaging for the measurement of the mass model parameters of the lensing galaxy. We demonstrate a novel technique of three-dimensional gravitational lens modeling for a single lens system with a resolved lensed rotation curve. We also describe the details of our custom IFU data analysis software, which performs optimal multi-fiber extraction, relative and absolute wavelength calibration to a few hundredths of a pixel RMS and nearly Poisson-limited sky subtraction.

  13. Flat acoustic lens by acoustic grating with curled slits

    KAUST Repository

    Peng, Pai

    2014-10-01

    We design a flat sub-wavelength lens that can focus acoustic wave. We analytically study the transmission through an acoustic grating with curled slits, which can serve as a material with tunable impedance and refractive index for acoustic waves. The effective parameters rely on the geometry of the slits and are independent of frequency. A flat acoustic focusing lens by such acoustic grating with gradient effective refractive index is designed. The focusing effect is clearly observed in simulations and well predicted by the theory. We demonstrate that despite the large impedance mismatch between the acoustic lens and the matrix, the intensity at the focal point is still high due to Fabry-Perot resonance.

  14. Investigation into photostability of soybean oils by thermal lens spectroscopy

    Science.gov (United States)

    Savi, E. L.; Malacarne, L. C.; Baesso, M. L.; Pintro, P. T. M.; Croge, C.; Shen, J.; Astrath, N. G. C.

    2015-06-01

    Assessment of photochemical stability is essential for evaluating quality and the shelf life of vegetable oils, which are very important aspects of marketing and human health. Most of conventional methods used to investigate oxidative stability requires long time experimental procedures with high consumption of chemical inputs for the preparation or extraction of sample compounds. In this work we propose a time-resolved thermal lens method to analyze photostability of edible oils by quantitative measurement of photoreaction cross-section. An all-numerical routine is employed to solve a complex theoretical problem involving photochemical reaction, thermal lens effect, and mass diffusion during local laser excitation. The photostability of pure oil and oils with natural and synthetic antioxidants is investigated. The thermal lens results are compared with those obtained by conventional methods, and a complete set of physical properties of the samples is presented.

  15. Investigation into photostability of soybean oils by thermal lens spectroscopy.

    Science.gov (United States)

    Savi, E L; Malacarne, L C; Baesso, M L; Pintro, P T M; Croge, C; Shen, J; Astrath, N G C

    2015-06-15

    Assessment of photochemical stability is essential for evaluating quality and the shelf life of vegetable oils, which are very important aspects of marketing and human health. Most of conventional methods used to investigate oxidative stability requires long time experimental procedures with high consumption of chemical inputs for the preparation or extraction of sample compounds. In this work we propose a time-resolved thermal lens method to analyze photostability of edible oils by quantitative measurement of photoreaction cross-section. An all-numerical routine is employed to solve a complex theoretical problem involving photochemical reaction, thermal lens effect, and mass diffusion during local laser excitation. The photostability of pure oil and oils with natural and synthetic antioxidants is investigated. The thermal lens results are compared with those obtained by conventional methods, and a complete set of physical properties of the samples is presented. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Hyperchromatic lens for recording time-resolved phenomena

    Science.gov (United States)

    Frayer, Daniel K.

    2017-07-11

    A method and apparatus for the capture of a high number of quasi-continuous effective frames of 2-D data from an event at very short time scales (from less than 10.sup.-12 to more than 10.sup.-8 seconds) is disclosed which allows for short recording windows and effective number of frames. Active illumination, from a chirped laser pulse directed to the event creates a reflection where wavelength is dependent upon time and spatial position is utilized to encode temporal phenomena onto wavelength. A hyperchromatic lens system receives the reflection and maps wavelength onto axial position. An image capture device, such as holography or plenoptic imaging device, captures the resultant focal stack from the hyperchromatic lens system in both spatial (imaging) and longitudinal (temporal) axes. The hyperchromatic lens system incorporates a combination of diffractive and refractive components to maximally separate focal position as a function of wavelength.

  17. Photographic zoom fisheye lens design for DSLR cameras

    Science.gov (United States)

    Yan, Yufeng; Sasian, Jose

    2017-09-01

    Photographic fisheye lenses with fixed focal length for cameras with different sensor formats have been well developed for decades. However, photographic fisheye lenses with variable focal length are rare on the market due in part to the greater design difficulty. This paper presents a large aperture zoom fisheye lens for DSLR cameras that produces both circular and diagonal fisheye imaging for 35-mm sensors and diagonal fisheye imaging for APS-C sensors. The history and optical characteristics of fisheye lenses are briefly reviewed. Then, a 9.2- to 16.1-mm F/2.8 to F/3.5 zoom fisheye lens design is presented, including the design approach and aberration control. Image quality and tolerance performance analysis for this lens are also presented.

  18. Broadband Wide Angle Lens Implemented with Dielectric Metamaterials

    Directory of Open Access Journals (Sweden)

    Anthony Starr

    2011-08-01

    Full Text Available The Luneburg lens is a powerful imaging device, exhibiting aberration free focusing for parallel rays incident from any direction. However, its advantages are offset by a focal surface that is spherical and thus difficult to integrate with standard planar detector and emitter arrays. Using the recently developed technique of transformation optics, it is possible to transform the curved focal surface to a flat plane while maintaining the perfect focusing behavior of the Luneburg over a wide field of view. Here we apply these techniques to a lesser-known refractive Luneburg lens and implement the design with a metamaterial composed of a semi-crystalline distribution of holes drilled in a dielectric. In addition, we investigate the aberrations introduced by various approximations made in the implementation of the lens. The resulting design approach has improved mechanical strength with small aberrations and is ideally suited to implementation at infrared and visible wavelengths.

  19. Bilateral ectopia lentis with isolated lens coloboma in Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Sahu, Sabin

    2016-12-01

    Full Text Available A rare case of bilateral ectopia lentis with isolated lens coloboma in Marfan syndrome is reported. A 21-year-old female presented with decreased vision in both eyes. Her unaided visual acuity was 20/200 and 20/400 in the right and left eye, respectively, improving to 20/40 with –4.5 DS/–3.0 DC x 10° correction in the right eye and 20/80 with –10.0 DS/–6.5 Dc x10° correction in the left eye. On slit lamp examination under mydriasis, both eyes revealed ectopia lentis with lens coloboma and stretched zonules. Fundus examination revealed pigmentary changes at the fovea. On systemic evaluation, she was diagnosed with Marfan syndrome. She was prescribed a refractive correction in form of a contact lens and kept under observation.

  20. Broadband focusing of underwater sound using a transparent pentamode lens.

    Science.gov (United States)

    Su, Xiaoshi; Norris, Andrew N; Cushing, Colby W; Haberman, Michael R; Wilson, Preston S

    2017-06-01

    An inhomogeneous acoustic metamaterial lens based on spatial variation of refractive index for broadband focusing of underwater sound is reported. The index gradient follows a modified hyperbolic secant profile designed to reduce aberration and suppress side lobes. The gradient index (GRIN) lens is comprised of transversely isotropic hexagonal microstructures with tunable quasi-static bulk modulus and mass density. In addition, the unit cells are impedance-matched to water and have in-plane shear modulus negligible compared to the effective bulk modulus. The flat GRIN lens is fabricated by cutting hexagonal centimeter scale hollow microstructures in aluminum plates, which are then stacked and sealed from the exterior water. Broadband focusing effects are observed within the homogenization regime of the lattice in both finite element simulations and underwater measurements (20-40 kHz). This design approach has potential applications in medical ultrasound imaging and underwater acoustic communications.