WorldWideScience

Sample records for tomography part i-technical

  1. Optical coherence tomography a clinical and technical update

    CERN Document Server

    Cunha-Vaz, José

    2012-01-01

    Optical Coherence Tomography represents the ultimate noninvasive  ocular imaging technique although being in the field for over two-decades. This book encompasses both medical and technical developments and recent achievements. Here, the authors cover the field of application from the anterior to the posterior ocular segments (Part I) and present a comprehensive review on the development of OCT. Important developments towards  clinical applications are covered in Part II, ranging from the adaptive optics to the integration on a slit-lamp, and passing through new structural  and functional information extraction from OCT data. The book is intended to be informative, coherent and comprehensive for both the medical and technical communities and aims at easing the communication between the two fields and bridging the gap between the two scientific communities.

  2. Iterative reconstruction techniques for computed tomography Part 1: Technical principles

    International Nuclear Information System (INIS)

    Willemink, Martin J.; Jong, Pim A. de; Leiner, Tim; Nievelstein, Rutger A.J.; Schilham, Arnold M.R.; Heer, Linda M. de; Budde, Ricardo P.J.

    2013-01-01

    To explain the technical principles of and differences between commercially available iterative reconstruction (IR) algorithms for computed tomography (CT) in non-mathematical terms for radiologists and clinicians. Technical details of the different proprietary IR techniques were distilled from available scientific articles and manufacturers' white papers and were verified by the manufacturers. Clinical results were obtained from a literature search spanning January 2006 to January 2012, including only original research papers concerning IR for CT. IR for CT iteratively reduces noise and artefacts in either image space or raw data, or both. Reported dose reductions ranged from 23 % to 76 % compared to locally used default filtered back-projection (FBP) settings, with similar noise, artefacts, subjective, and objective image quality. IR has the potential to allow reducing the radiation dose while preserving image quality. Disadvantages of IR include blotchy image appearance and longer computational time. Future studies need to address differences between IR algorithms for clinical low-dose CT. circle Iterative reconstruction technology for CT is presented in non-mathematical terms. (orig.)

  3. Physico-technical irradiation planning for the therapy of oesophagus carcinomas by means of computed whole-body tomography

    International Nuclear Information System (INIS)

    Ammon, J.; Greiner, K.; Kaesberg, P.

    1980-01-01

    It is particularly difficult to establish a physico-technical irradiation plan for the thoracic part of an oesophagus carcinoma. This is due to the considerable modifications of the thoracic cross-section within the longitudinal axis of the radiation field. Therefore, tomographic cross-sections were made of the upper, the middle and the lower plane of the radiation field. The percentage dose distributions could be determined with a process computer (system TPS, Philips) for different irradiation techniques and irradiation equipments. Examinations of 21 patients showed that the best dose distribution, i.e. a distribution which spares the lung and spinal marrow regions adjacent to the target volume, is obtained by an excentric moving field therapy. Furthermore, localisation and dimensions of inhomogeneities are indicated by computer tomography which makes possible to take into consideration these inhomogeneities when calculating the dose. It was found that the irradiation times can so be reduced by more than 20%. We are therefore of the opinion that it is necessary to establish individual cross-sections of the body by computed tomography when elaborating a physico-technical irradiation plan for the treatment of an oesophagus carcinoma. (orig.) [de

  4. Workshop 97. Part I. Proceedings

    International Nuclear Information System (INIS)

    1996-12-01

    The complete Proceedings, in 4 volumes, contain contributions by staff members of the Czech Technical University in Prague, the Technical University in Brno, and the Technical University (former University of Mining) in Ostrava, covering all branches of science and technology dealt with by the 3 universities. Part I includes contributions in mathematics, physics, engineering informatics and cybernetics, and computers. Out of these, 13 have been input to INIS. (P.A.)

  5. Workshop 97. Part I. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The complete Proceedings, in 4 volumes, contain contributions by staff members of the Czech Technical University in Prague, the Technical University in Brno, and the Technical University (former University of Mining) in Ostrava, covering all branches of science and technology dealt with by the 3 universities. Part I includes contributions in mathematics, physics, engineering informatics and cybernetics, and computers. Out of these, 13 have been input to INIS. (P.A.).

  6. single photon emission tomography and positron emission tomography - Part 1 (October 2012), Part 2 (October 2010)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2010-10-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) and the positron emission tomography (PET) imaging techniques. Part 1 Content: 1 - Introduction: anatomic, functional and molecular imaging; 2 - Radiotracers: chemical and physical constraints, gamma photon emitters, positon emitters, radioisotopes production, emitters type and imaging techniques; 3 - Gamma cameras; 4 - Quantification in emission tomography: attenuation, scattering, un-stationary spatial resolution; 5 - Synthesis and conclusion. Part 2 content: 1 - Positon emitters; 2 - Positons detection: Coincidence detection (electronic collimation, PET detectors with gamma cameras, dedicated PET detectors, spectrometry); PET detectors type; time-of-flight PET; 2D PET; 3D PET; 3 - Quantification in emission tomography: detected events, attenuation, scattering, fortuitous coincidences, standardisation; 4 - Common SPECT and PET problems: partial volume effect, movement, tomographic reconstruction, calibration, dead time; 5 - Synthesis and conclusion

  7. Technical property and application of industrial computed tomography

    International Nuclear Information System (INIS)

    Sun Lingxia; Ye Yunchang

    2006-01-01

    The main technical property of industrial computed tomography (ICT) and its application in non-destructive testing (NDT) were described. And some examples of ICT applications in such fields as defects detection, welding quality, density uniformity, structure analysis and making-up quality were given. (authors)

  8. Technical aspects of positron emission tomography/computed tomography in radiotherapy treatment planning.

    Science.gov (United States)

    Scripes, Paola G; Yaparpalvi, Ravindra

    2012-09-01

    The usage of functional data in radiation therapy (RT) treatment planning (RTP) process is currently the focus of significant technical, scientific, and clinical development. Positron emission tomography (PET) using ((18)F) fluorodeoxyglucose is being increasingly used in RT planning in recent years. Fluorodeoxyglucose is the most commonly used radiotracer for diagnosis, staging, recurrent disease detection, and monitoring of tumor response to therapy (Lung Cancer 2012;76:344-349; Lung Cancer 2009;64:301-307; J Nucl Med 2008;49:532-540; J Nucl Med 2007;48:58S-67S). All the efforts to improve both PET and computed tomography (CT) image quality and, consequently, lesion detectability have a common objective to increase the accuracy in functional imaging and thus of coregistration into RT planning systems. In radiotherapy, improvement in target localization permits reduction of tumor margins, consequently reducing volume of normal tissue irradiated. Furthermore, smaller treated target volumes create the possibility of dose escalation, leading to increased chances of tumor cure and control. This article focuses on the technical aspects of PET/CT image acquisition, fusion, usage, and impact on the physics of RTP. The authors review the basic elements of RTP, modern radiation delivery, and the technical parameters of coregistration of PET/CT into RT computerized planning systems. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Determining casting defects in near-net shape casting aluminum parts by computed tomography

    Science.gov (United States)

    Li, Jiehua; Oberdorfer, Bernd; Habe, Daniel; Schumacher, Peter

    2018-03-01

    Three types of near-net shape casting aluminum parts were investigated by computed tomography to determine casting defects and evaluate quality. The first, second, and third parts were produced by low-pressure die casting (Al-12Si-0.8Cu-0.5Fe-0.9Mg-0.7Ni-0.2Zn alloy), die casting (A356, Al-7Si-0.3Mg), and semi-solid casting (A356, Al-7Si-0.3Mg), respectively. Unlike die casting (second part), low-pressure die casting (first part) significantly reduced the formation of casting defects (i.e., porosity) due to its smooth filling and solidification under pressure. No significant casting defect was observed in the third part, and this absence of defects indicates that semi-solid casting could produce high-quality near-net shape casting aluminum parts. Moreover, casting defects were mostly distributed along the eutectic grain boundaries. This finding reveals that refinement of eutectic grains is necessary to optimize the distribution of casting defects and reduce their size. This investigation demonstrated that computed tomography is an efficient method to determine casting defects in near-net shape casting aluminum parts.

  10. 36 CFR Appendix D to Part 1191 - Technical

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Technical D Appendix D to Part 1191 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE...; ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY GUIDELINES Pt. 1191, App. D Appendix D to Part 1191—Technical...

  11. Coastal pollution emergency plan. Part I

    Energy Technology Data Exchange (ETDEWEB)

    Semanov, G.; Volkov, V.; Somkin, V.; Iljushenko-Krylov, D.

    1997-12-31

    A higher degree of ecological safety in ship traffic depends on onboard measures as well as reception facilities on shore, treatment of ship generated wastes and preparedness for combating emergency oil spills. The problem is particularly acute in the North Sea Route (NSR) due to high vulnerability of the Arctic ecosystems, low rates of natural degradation of oil, absence of forward coastal infrastructure, low efficiency of oil combating means in ice conditions and severe climatic conditions. Oil spills in the NSR are likely to occur as the offshore production and transportation of oil increase. Therefore a regional Oil Spill Contingency Plan (OSCP) is being constructed and developed on 3 levels: 1) Development of concept, definition of response organisations and their technical ability (Part I). 2) Collection and analysis of information, development of scenarios of probable oil spills, clearing of the funding mechanism and basis for additional outside co-operation from other Russian regions and circumpolar countries (part II). 3) Development of NSR OSCP (part III). The present report (part I) provides the plan concept, rescue organisations and data on types and amounts of the oil spill combating technical means and of the floating facilities available in the NSR or it`s vicinity. The concept takes into account subdivision of the Route, interaction and links between responsible organisations, realities of the Russian Arctic such as transport, communications, energy, labour resources etc. and requirements of the IMO and of the International Convention OPRC 90. According to Russian legislation implementation of combating operations at sea is the responsibility of the Maritime Pollution Control and Salvage Administration that consists of a Central Administration and basin emergency divisions situated in Murmansk and Nahodka. The body is responsible for carrying out cleaning operations at sea from installations and may be assisted by resources and means of the co

  12. A Quantum Field Approach for Advancing Optical Coherence Tomography Part I: First Order Correlations, Single Photon Interference, and Quantum Noise.

    Science.gov (United States)

    Brezinski, M E

    2018-01-01

    Optical coherence tomography has become an important imaging technology in cardiology and ophthalmology, with other applications under investigations. Major advances in optical coherence tomography (OCT) imaging are likely to occur through a quantum field approach to the technology. In this paper, which is the first part in a series on the topic, the quantum basis of OCT first order correlations is expressed in terms of full field quantization. Specifically first order correlations are treated as the linear sum of single photon interferences along indistinguishable paths. Photons and the electromagnetic (EM) field are described in terms of quantum harmonic oscillators. While the author feels the study of quantum second order correlations will lead to greater paradigm shifts in the field, addressed in part II, advances from the study of quantum first order correlations are given. In particular, ranging errors are discussed (with remedies) from vacuum fluctuations through the detector port, photon counting errors, and position probability amplitude uncertainty. In addition, the principles of quantum field theory and first order correlations are needed for studying second order correlations in part II.

  13. A Quantum Field Approach for Advancing Optical Coherence Tomography Part I: First Order Correlations, Single Photon Interference, and Quantum Noise

    Science.gov (United States)

    Brezinski, ME

    2018-01-01

    Optical coherence tomography has become an important imaging technology in cardiology and ophthalmology, with other applications under investigations. Major advances in optical coherence tomography (OCT) imaging are likely to occur through a quantum field approach to the technology. In this paper, which is the first part in a series on the topic, the quantum basis of OCT first order correlations is expressed in terms of full field quantization. Specifically first order correlations are treated as the linear sum of single photon interferences along indistinguishable paths. Photons and the electromagnetic (EM) field are described in terms of quantum harmonic oscillators. While the author feels the study of quantum second order correlations will lead to greater paradigm shifts in the field, addressed in part II, advances from the study of quantum first order correlations are given. In particular, ranging errors are discussed (with remedies) from vacuum fluctuations through the detector port, photon counting errors, and position probability amplitude uncertainty. In addition, the principles of quantum field theory and first order correlations are needed for studying second order correlations in part II.

  14. Neutron Tomography Application for Aircraft-parts and Root of Ginseng

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yi Kyung; Lee, Seung Wook; Sim, Chul Mu; Jeon, Jin Su; Kim, Tae Ju [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2005-07-01

    The neutron computerized tomography is considered to be a complementary tool to X-ray tomography in the sense that neutron interacts with atomic nucleus, otherwise X-ray interacts with an orbital electron of atom. The neutron tomography compared with X-ray tomography has a relatively short history. It is employed in stationary, as neutron sources are produced by the nuclear reactor. The full potential of the neutron tomography has yet to be investigated. Since, HANARO NRF was installed in 1995, the neutron radiography research group of KAERI has been developed the non-destructive testing methods by the computer tomography served for aerospace industry and agricultural industry. Concerning to NDT for aerospace, research was cooperated with Korean Air force. At the first stage, research was focused to find the micro-cracks based on internal passages inside aircraft parts and residual core of turbine blade. Concerning to NDT for agriculture, research was cooperated with the Agricultural Development and Technology Center. Research was focused to find the alive roots of Korean ginseng.

  15. Optical coherence tomography angiography: Technical principles and clinical applications in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ahmed M Hagag

    2017-01-01

    Full Text Available Optical coherence tomography angiography (OCTA is a functional extension of OCT that provides information on retinal and choroidal circulations without the need for dye injections. With the recent development of high-speed OCT systems and efficient algorithms, OCTA has become clinically feasible. In this review article, we discuss the technical principles of OCTA, including image processing and artifacts, and its clinical applications in ophthalmology. We summarize recent studies which qualitatively or quantitatively assess disease presentation, progression, and/or response to treatment.

  16. DOE underground storage tank waste remediation chemical processing hazards. Part I: Technology dictionary

    International Nuclear Information System (INIS)

    DeMuth, S.F.

    1996-10-01

    This document has been prepared to aid in the development of Regulating guidelines for the Privatization of Hanford underground storage tank waste remediation. The document has been prepared it two parts to facilitate their preparation. Part II is the primary focus of this effort in that it describes the technical basis for established and potential chemical processing hazards associated with Underground Storage Tank (UST) nuclear waste remediation across the DOE complex. The established hazards involve those at Sites for which Safety Analysis Reviews (SARs) have already been prepared. Potential hazards are those involving technologies currently being developed for future applications. Part I of this document outlines the scope of Part II by briefly describing the established and potential technologies. In addition to providing the scope, Part I can be used as a technical introduction and bibliography for Regulatory personnel new to the UST waste remediation, and in particular Privatization effort. Part II of this document is not intended to provide examples of a SAR Hazards Analysis, but rather provide an intelligence gathering source for Regulatory personnel who must eventually evaluate the Privatization SAR Hazards Analysis

  17. Physical and technical basis of positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Bauer, R.

    1994-01-01

    Positron emission tomography utilizes the annihilation of positrons, generating pairs of gamma quanta which are emitted in opposing directions. 'Electronic collimation' is performed by coincident detection of both quanta. Thus, there is no need for mechanical collimators and no limiting connection between sensitivity and spatial resolution. Transversal tomograms are reconstructed from the projection data by means of highly sophisticated data processing. The half life of the most positron emitters used in medical applications is short and of the order of some minutes. Therefore, many positron emitters have to be produced on-side by means of a cyclotron. PET is superior to SPECT with respect to physical and technical aspects, but the high costs of PET limit its wide-spread use up to now. (orig.) [de

  18. Towards automated diffraction tomography: Part I-Data acquisition

    International Nuclear Information System (INIS)

    Kolb, U.; Gorelik, T.; Kuebel, C.; Otten, M.T.; Hubert, D.

    2007-01-01

    The ultimate aim of electron diffraction data collection for structure analysis is to sample the reciprocal space as accurately as possible to obtain a high-quality data set for crystal structure determination. Besides a more precise lattice parameter determination, fine sampling is expected to deliver superior data on reflection intensities, which is crucial for subsequent structure analysis. Traditionally, three-dimensional (3D) diffraction data are collected by manually tilting a crystal around a selected crystallographic axis and recording a set of diffraction patterns (a tilt series) at various crystallographic zones. In a second step, diffraction data from these zones are combined into a 3D data set and analyzed to yield the desired structure information. Data collection can also be performed automatically, with the recent advances in tomography acquisition providing a suitable basis. An experimental software module has been developed for the Tecnai microscope for such an automated diffraction pattern collection while tilting around the goniometer axis. The module combines STEM imaging with diffraction pattern acquisition in nanodiffraction mode. It allows automated recording of diffraction tilt series from nanoparticles with a size down to 5 nm

  19. Computed tomography as a tool for tolerance verification of industrial parts

    DEFF Research Database (Denmark)

    Müller, Pavel; Cantatore, Angela; Andreasen, J.L.

    2013-01-01

    Computed tomography (CT) is becoming an important technology for industrial applications, enabling fast and accurate control of manufactured parts. In only a few minutes, a complete 3D model of a part may be obtained, allowing measurements of external and internal features. This paper presents...

  20. Technical competence in cardiovascular magnetic resonance and computed tomography

    International Nuclear Information System (INIS)

    Fernandes, Juliano Lara; Shiozaki, Afonso Akio; Azevedo Filho, Clerio Francisco de; Rochitte, Carlos Eduardo; Pinto, Ibraim Marciarelli Francisco; Lopes, Marly Maria Uellendahl; Schvartzman, Paulo Roberto

    2009-01-01

    Cardiovascular magnetic resonance and computed tomography have evolved as very practical and useful techniques applied in clinical cardiology. Due to their rapid acceptance in the cardiology community and widespread use, training of both cardiologists and radiologists on this subspecialty has not been homogeneous so far. This in part explains significant differences observed in the diverse background found in today’s practicing physicians who execute these exams. In order to guide training facilities as well as both payers, contractors and general cardiologists ordering the exam, this document provides a minimum standard that should be accomplished by all physicians who pursue education in the field and for those who already practice in it. The clinical competences listed in this statement are by no means thorough but should be required by all those involved in cardiovascular magnetic resonance and computed tomography as the customary requirements for current and future practitioners. (author)

  1. Intraarticular Sacroiliac Joint Injection Under Computed Tomography Fluoroscopic Guidance: A Technical Note to Reduce Procedural Time and Radiation Dose

    International Nuclear Information System (INIS)

    Paik, Nam Chull

    2016-01-01

    PurposeA technique for computed tomography fluoroscopy (CTF)-guided intraarticular (IA) sacroiliac joint (SIJ) injection was devised to limit procedural time and radiation dose.MethodsOur Institutional Review Board approved this retrospective analysis and waived the requirement for informed consent. Overall, 36 consecutive diagnostic or therapeutic IA SIJ injections (unilateral, 20; bilateral, 16) performed in 34 patients (female, 18; male, 16) with a mean age of 45.5 years (range 20–76 years) under CTF guidance were analyzed, assessing technical success (i.e., IA contrast spread), procedural time, and radiation dose.ResultsAll injections were successful from a technical perspective and were free of serious complications. Respective median procedural times and effective doses of SIJ injection were as follows: unilateral, 5.28 min (range 3.58–8.00 min) and 0.11 millisievert (mSv; range 0.07–0.24 mSv); and bilateral, 6.72 min (range 4.17–21.17 min) and 0.11 mSv (range 0.09–0.51 mSv).ConclusionsGiven the high rate of technical success achieved in limited time duration and with little radiation exposure, CTF-guided IA SIJ injection is a practical and low-risk procedure.

  2. Intraarticular Sacroiliac Joint Injection Under Computed Tomography Fluoroscopic Guidance: A Technical Note to Reduce Procedural Time and Radiation Dose

    Energy Technology Data Exchange (ETDEWEB)

    Paik, Nam Chull, E-mail: pncspine@gmail.com [Arumdaun Wooldul Spine Hospital, Department of Radiology (Korea, Republic of)

    2016-07-15

    PurposeA technique for computed tomography fluoroscopy (CTF)-guided intraarticular (IA) sacroiliac joint (SIJ) injection was devised to limit procedural time and radiation dose.MethodsOur Institutional Review Board approved this retrospective analysis and waived the requirement for informed consent. Overall, 36 consecutive diagnostic or therapeutic IA SIJ injections (unilateral, 20; bilateral, 16) performed in 34 patients (female, 18; male, 16) with a mean age of 45.5 years (range 20–76 years) under CTF guidance were analyzed, assessing technical success (i.e., IA contrast spread), procedural time, and radiation dose.ResultsAll injections were successful from a technical perspective and were free of serious complications. Respective median procedural times and effective doses of SIJ injection were as follows: unilateral, 5.28 min (range 3.58–8.00 min) and 0.11 millisievert (mSv; range 0.07–0.24 mSv); and bilateral, 6.72 min (range 4.17–21.17 min) and 0.11 mSv (range 0.09–0.51 mSv).ConclusionsGiven the high rate of technical success achieved in limited time duration and with little radiation exposure, CTF-guided IA SIJ injection is a practical and low-risk procedure.

  3. Handbook of technical diagnostics fundamentals and application to structures and systems

    CERN Document Server

    2013-01-01

    This book presents concepts, methods and techniques to examine symptoms of faults and failures of structures, systems and components and to monitor functional performance and structural integrity. The book is organized in five parts. Part A introduces the scope and application of technical diagnostics and gives a comprehensive overview of the physics of failure. Part B presents all relevant methods and techniques for diagnostics and monitoring: from stress, strain, vibration analysis, nondestructive evaluation, thermography and industrial radiology to computed tomography and subsurface microstructural analysis. Part C cores the principles and concepts of technical failure analysis, illustrates case studies, and outlines machinery diagnostics with an emphasis on tribological systems. Part D describes the application of structural health monitoring and performance control to plants and the technical infrastructure, including buildings, bridges, pipelines, electric power stations, offshore wind structures, and r...

  4. Discrete Tomography and Imaging of Polycrystalline Structures

    DEFF Research Database (Denmark)

    Alpers, Andreas

    High resolution transmission electron microscopy is commonly considered as the standard application for discrete tomography. While this has yet to be technically realized, new applications with a similar flavor have emerged in materials science. In our group at Ris� DTU (Denmark's National...... Laboratory for Sustainable Energy), for instance, we study polycrystalline materials via synchrotron X-ray diffraction. Several reconstruction problems arise, most of them exhibit inherently discrete aspects. In this talk I want to give a concise mathematical introduction to some of these reconstruction...... problems. Special focus is on their relationship to classical discrete tomography. Several open mathematical questions will be mentioned along the way....

  5. 76 FR 13662 - Hewlett Packard Company, Enterprise Business Division, Technical Services America, Global Parts...

    Science.gov (United States)

    2011-03-14

    ... Packard Company, Enterprise Business Division, Technical Services America, Global Parts Supply Chain Group, Including Leased Workers From QFlex, North America Logistics, and UPS, Headquartered in Palo Alto, CA... Business Division, Technical Services America, Global Parts Supply Chain Group, Including Leased Workers...

  6. 76 FR 10394 - Hewlett Packard Company, Enterprise Business Division, Technical Services America, Global Parts...

    Science.gov (United States)

    2011-02-24

    ... Packard Company, Enterprise Business Division, Technical Services America, Global Parts Supply Chain Group, Including Leased Workers From Qflex, North America Logistics, and UPS, Headquartered in Palo Alto, CA... Business Division, Technical Services America, Global Parts Supply Chain Group, Including Leased Workers...

  7. [Axial computer tomography of the neurocranium (author's transl)].

    Science.gov (United States)

    Stöppler, L

    1977-05-27

    Computer tomography (CT), a new radiographic examination technique, is very highly efficient, for it has high informative content with little stress for the patient. In contrast to the conventional X-ray technology, CT succeeds, by direct presentation of the structure of the soft parts, in obtaining information which comes close to that of macroscopic neuropathology. The capacity and limitations of the method at the present stage of development are reported. Computer tomography cannot displace conventional neuroradiological methods of investigation, although it is rightly presented as a screening method and helps towards selective use. Indications, technical integration and handling of CT are prerequisites for the exhaustive benefit of the excellent new technique.

  8. Fuel Element Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Burley, H.H. [ed.

    1956-08-01

    It is the purpose of the Fuel Element Technical Manual to Provide a single document describing the fabrication processes used in the manufacture of the fuel element as well as the technical bases for these processes. The manual will be instrumental in the indoctrination of personnel new to the field and will provide a single data reference for all personnel involved in the design or manufacture of the fuel element. The material contained in this manual was assembled by members of the Engineering Department and the Manufacturing Department at the Hanford Atomic Products Operation between the dates October, 1955 and June, 1956. Arrangement of the manual. The manual is divided into six parts: Part I--introduction; Part II--technical bases; Part III--process; Part IV--plant and equipment; Part V--process control and improvement; and VI--safety.

  9. MMX-I: data-processing software for multimodal X-ray imaging and tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bergamaschi, Antoine, E-mail: antoine.bergamaschi@synchrotron-soleil.fr; Medjoubi, Kadda [Synchrotron SOLEIL, BP 48, Saint-Aubin, 91192 Gif sur Yvette (France); Messaoudi, Cédric; Marco, Sergio [Université Paris-Saclay, CNRS, Université Paris-Saclay, F-91405 Orsay (France); Institut Curie, INSERM, PSL Reseach University, F-91405 Orsay (France); Somogyi, Andrea [Synchrotron SOLEIL, BP 48, Saint-Aubin, 91192 Gif sur Yvette (France)

    2016-04-12

    The MMX-I open-source software has been developed for processing and reconstruction of large multimodal X-ray imaging and tomography datasets. The recent version of MMX-I is optimized for scanning X-ray fluorescence, phase-, absorption- and dark-field contrast techniques. This, together with its implementation in Java, makes MMX-I a versatile and friendly user tool for X-ray imaging. A new multi-platform freeware has been developed for the processing and reconstruction of scanning multi-technique X-ray imaging and tomography datasets. The software platform aims to treat different scanning imaging techniques: X-ray fluorescence, phase, absorption and dark field and any of their combinations, thus providing an easy-to-use data processing tool for the X-ray imaging user community. A dedicated data input stream copes with the input and management of large datasets (several hundred GB) collected during a typical multi-technique fast scan at the Nanoscopium beamline and even on a standard PC. To the authors’ knowledge, this is the first software tool that aims at treating all of the modalities of scanning multi-technique imaging and tomography experiments.

  10. Japanese contributions to IAEA INTOR workshop, phase two A, part 2, chapter I: introduction, and chapter II: summary

    International Nuclear Information System (INIS)

    Mori, Sigeru; Tomabechi, Ken; Fujisawa, Noboru; Iida, Hiromasa; Sugihara, Masayoshi; Seki, Masahiro; Honda, Tsutomu; Kasai, Masao; Itoh, Shin-ichi.

    1985-07-01

    This report corresponds to Chapters I and II of Japanese contribution report to IAEA INTOR Workshop, Phase Two A, Part 2. The major objectives of the INTOR workshop, Phase Two A, Part 2 are to study critical technical issues, and to assess scientific and technical data bases, and to finally upgrade the INTOR design concept. To study critical technical issues that affect the feasibility or practicability of the INTOR design concept, the following five groups are organized; (A) Impurity control, (B) RF heating and current drive, (C) Transient electromagnetics, (D) Maintainability, (E) Technical benefit. In addition to those groups, the three disciplinary groups are organized to assess the worldiode scientific and technical data bases that exist now and that will exist 4-5 years to support the detailed design and construction of an INTOR-like machine, and to identify additional R D that is required; (F) Physics, (G) Engineering, (H) Nuclear. (author)

  11. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  12. Nuclear power plant simulators for operator licensing and training. Part I. The need for plant-reference simulators. Part II. The use of plant-reference simulators

    International Nuclear Information System (INIS)

    Rankin, W.L.; Bolton, P.A.; Shikiar, R.; Saari, L.M.

    1984-05-01

    Part I of this report presents technical justification for the use of plant-reference simulators in the licensing and training of nuclear power plant operators and examines alternatives to the use of plant-reference simulators. The technical rationale is based on research on the use of simulators in other industries, psychological learning and testing principles, expert opinion and user opinion. Part II discusses the central considerations in using plant-reference simulators for licensing examination of nuclear power plant operators and for incorporating simulators into nuclear power plant training programs. Recommendations are presented for the administration of simulator examinations in operator licensing that reflect the goal of maximizing both reliability and validity in the examination process. A series of organizational tasks that promote the acceptance, use, and effectiveness of simulator training as part of the onsite training program is delineated

  13. Dimensional measurement of micro-moulded parts by computed tomography

    DEFF Research Database (Denmark)

    Ontiveros, S.; Yagüe-Fabra, J.A.; Jiménez, R.

    2012-01-01

    Computed tomography (CT) is progressively assuming an important role in metrology applications and great efforts are being made in order to turn it into a reliable and standardized measuring technology. CT is typically used for non-destructive tests, but it is currently becoming very popular for ...... and the analysis of the results provide valuable conclusions about the advantages and drawbacks of using CT metrology in comparison with other measuring systems when these techniques are employed for the quality control of micro-moulded parts.......Computed tomography (CT) is progressively assuming an important role in metrology applications and great efforts are being made in order to turn it into a reliable and standardized measuring technology. CT is typically used for non-destructive tests, but it is currently becoming very popular...... for dimensional metrology applications due to its strategic advantages such as the capability of performing measurements on both the component's surface and volume, allowing inspection possibilities to otherwise non-accessible internal features. This paper focuses on the dimensional verification of two micro...

  14. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  15. Technical Reports (Part I). End of Project Report, 1968-1971, Volume III.

    Science.gov (United States)

    Western Nevada Regional Education Center, Lovelock.

    The pamphlets included in this volume are technical reports prepared as outgrowths of the Student Information Systems of the Western Nevada Regional Education Center (WN-REC) funded by a Title III (Elementary and Secondary Education Act) grant. These reports describe methods of interpreting the printouts from the Student Information System;…

  16. Single-Photon Computed Tomography With Large Position-Sensitive Phototubes*

    Science.gov (United States)

    Feldmann, John; Ranck, Amoreena; Saunders, Robert S.; Welsh, Robert E.; Bradley, Eric L.; Saha, Margaret S.; Kross, Brian; Majewski, Stan; Popov, Vladimir; Weisenberger, Andrew G.; Wojcik, Randolph

    2000-10-01

    Position-sensitive photomultiplier tubes (PSPMTs) coupled to pixelated CsI(Tl) scintillators have been used with parallel-hole collimators to view the metabolism in small animals of radiopharmaceuticals tagged with ^125I. We report here our preliminary results analyzed using a tomography program^1 written in IDL programming language. The PSPMTs are mounted on a rotating gantry so as to view the subject animal from any azimuth. Preliminary results to test the tomography algorithm have been obtained by placing a variety of plastic mouse-brain phantoms (loaded with Na^125I) in front of one of the detectors and rotating the phantom in steps through 360 degrees. Results of this simulation taken with a variety of collimator hole sizes will be compared and discussed. Extentions of this technique to the use of very small PSPMTs (Hamamatsu M-64) which are capable of a very close approach to those parts of the animal of greatest interest will be described. *Supported in part by The Department of Energy, The National Science Foundation, The American Diabetes Association, The Howard Hughes Foundation and The Jeffress Trust. 1. Tomography algorithm kindly provided by Dr. S. Meikle of The Royal Prince Albert Hospital, Sydney, Australia

  17. Nuclear energy and public safety (Part II): a bibliography of technical resources

    International Nuclear Information System (INIS)

    Gabriel, M.R.

    1982-01-01

    Part 2 of the bibliography focuses on technical information of interest to those concerned with the operation of nuclear power plants and the subjects of safety and accidents. A subject index included after the bibliography provides a breakdown of the references into seven categories. There is also an author index. The material cited is available through the National Technical Information Service (NTIS) in Springfield, Virginia

  18. Technical aspects of X-ray micro-computed tomography. Initial experience of 27-μm resolution using feldkamp cone-beam reconstruction

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Suzuki, Masahiro; Kohara, Kazushi; Iinuma, Gen; Moriyama, Noriyuki

    2007-01-01

    The objective of this study was to introduce the technical utility of micro-computed tomography (CT) with 27-μm resolution by cone-beam CT algorithm. Whole-body micro-CT scans were performed to honeybee. Two- and three-dimensional image analyses were performed by originally developed and available open-source software for acquired images. The original contribution of this work is to describe the technical characteristics of the X-ray micro-CT system, keeping a small experimental insect in a unique condition. Micro-CT may be used as a rapid prototyping tool to research and understand the high-resolution system with Feldkamp cone-beam reconstruction. (author)

  19. Osteoid osteomas in common and in technically challenging locations treated with computed tomography-guided percutaneous radiofrequency ablation

    International Nuclear Information System (INIS)

    Mylona, Sophia; Patsoura, Sofia; Karapostolakis, Georgios; Galani, Panagiota; Pomoni, Anastasia; Thanos, Loukas

    2010-01-01

    To evaluate the efficacy of computed tomography (CT)-guided radiofrequency (RF) ablation for the treatment of osteoid osteomas in common and in technically challenging locations. Twenty-three patients with osteoid osteomas in common (nine cases) and technically challenging [14 cases: intra-articular (n = 7), spinal (n = 5), metaphyseal (n = 2)] positions were treated with CT-guided RF ablation. Therapy was performed under conscious sedation with a seven-array expandable RF electrode for 8-10 min at 80-110 C and power of 90-110 W. The patients went home under instruction. A brief pain inventory (BPI) score was calculated before and after (1 day, 4 weeks, 6 months and 1 year) treatment. All procedures were technically successful. Primary clinical success was 91.3% (21 of total 23 patients), despite the lesions' locations. BPI score was dramatically reduced after the procedure, and the decrease in BPI score was significant (P < 0.001, paired t-test; n - 1 = 22) for all periods during follow up. Two patients had persistent pain after 1 month and were treated successfully with a second procedure (secondary success rate 100%). No immediate or delayed complications were observed. CT-guided RF ablation is safe and highly effective for treatment of osteoid osteomas, even in technically difficult positions. (orig.)

  20. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Marchiori, Edson; Oliveira, Hugo

    2010-01-01

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  1. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno, E-mail: brunohochhegger@googlemail.co [Hospital Moinhos de Vento, Porto Alegre, RS (Brazil); Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Liverpool Heart and Chest Hospital, Liverpool (United Kingdom); Oliveira, Hugo [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil)

    2010-07-15

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  2. A State Articulated Instructional Objectives Guide for Occupational Education Programs. State Pilot Model for Drafting (Graphic Communications). Part I--Basic. Part II--Specialty Programs. Section A (Mechanical Drafting and Design). Section B (Architectural Drafting and Design).

    Science.gov (United States)

    North Carolina State Dept. of Community Colleges, Raleigh.

    A two-part articulation instructional objective guide for drafting (graphic communications) is provided. Part I contains summary information on seven blocks (courses) of instruction. They are as follow: introduction; basic technical drafting; problem solving in graphics; reproduction processes; freehand drawing and sketching; graphics composition;…

  3. Brain receptor single-photon emission computer tomography with 123I Datscan in Parkinson's disease

    International Nuclear Information System (INIS)

    Minchev, D.; Peshev, N.; Kostadinova, I.; Grigorova, O.; Trindev, P.; Shotekov, P.

    2005-01-01

    Clinical aspects of Parkinson's disease are not enough for the early diagnosis of the disease. Positron emission tomography and the receptor single - photon emission tomography can be used for imaging functional integrity of nigrostriatal dopaminergic structures. 24 patient (17 men and 7 women) were investigated. 20 of them are with Parkinson's disease and 4 are with essential tremor. The radiopharmaceutical - 123I-Datscan (ioflupane, bind with 123I) represent a cocaine analogue with selective affinity to dopamine transporters, located in the dopaminergic nigrostriatal terminals in the striatum. Single - photon emission computer tomography was performed with SPECT gamma camera (ADAC, SH Epic detector). The scintigraphic study was made 3 to 6 hours after intravenous injection of the radiopharmaceutical - 123I- Datscan in dose 185 MBq. 120 frames are registered with duration of each one 22 seconds and gamma camera rotation 360. After generation of transversal slices we generated two composites pictures. The first composite picture image the striatum, the second - the occipital region. Two ratios were calculated representing the uptake of the radiopharmaceutical in the left and right striatum. Qualitative and quantitative criteria were elaborated for evaluating the scintigraphic patterns. Decreased, nonhomogeneous and asymmetric uptake of the radiopharmaceutical coupled with low quantitative parameters in range from 1.44 to 2.87 represents the characteristic scintigraphic pattern for Parkinson's disease with clear clinical picture. Homogenous with high intensity and symmetric uptake of the radiopharmaceutical in the striatum coupled with his clear frontier and with quantitative parameters up to 4.40 represent the scintigraphic pattern in two patients with essential tremor. Receptor single - photon emission computer tomography with 123I - Datscan represents an accurate nuclear-medicine method for precise diagnosis of Parkinson's disease and for its differentiation from

  4. Hysterosalpingographic Appearances of Female Genital Tract Tuberculosis: Part I. Fallopian Tube

    Directory of Open Access Journals (Sweden)

    Firoozeh Ahmadi

    2014-01-01

    Full Text Available Female genital tuberculosis (TB remains as a major cause of tubal obstruction leading to infertility, especially in developing countries. The global prevalence of genital tuberculosis has increased during the past two decades due to increasing acquired immunodeficiency syndrome (AIDS. Genital TB is commonly asymptomatic, and it is diagnosed during infertility investigations. Despite of recent advances in imaging tools, such as computerized tomography (CT scan, magnetic resonance imaging (MRI and ultrasongraphy, hysterosalpingography is still the standard screening test for evaluation of tubal infertility and a valuable tool for diagnosis of female genital tuberculosis. Tuberculosis gives rise to various appearances on hysterosalpingography (HSG from non-specific changes to specific findings. The present pictorial review illustrates and describes specific and non-specific radiographic features of female genital tuberculosis in two parts. Part I presents specific findings of tuberculosis related to tubes such as "beaded tube", "golf club tube", "pipestem tube", "cobble stone tube" and "leopard skin tube". Part II describes adverse effects of tuberculosis on structure of endometrium and radiological specific findings such as "dwarfed" uterus with lymphatic intravasation and occluded tubes, "T-shaped" tuberculosis uterus, "pseudounicornuate" uterus and "Collar-stud abscess", which have not been encountered in the majority of non-tuberculosis cases.

  5. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  6. Quality criteria for abdominal computerized tomography

    International Nuclear Information System (INIS)

    Huebener, K.H.; Kurtz, B.; Metzger, H.O.F.

    1985-01-01

    Quality, not only in obdominal computerized tomography, is determined by the measurable technical parameters and, to an important extent, also bei individual factors, among which the diagnostic skill and experience of the examiner is one of the most decisive. These individual factors and the part they play with regard to the quality of CT-assisted diagnosis may well equal the technical parameters, as they significantly influence the course of examinations, resulting indications for contrast medium application, and the sensitivity of the diagnosis. The authors are convinced that especially for abdominal CT, standardized examination techniques inevitably would bring down the diagnostic quality. The technical parameters are of equal significance to achieving the diagnostic optimum, and to these parameters one has to count equipment characteristics as well as the data given by the examiner. Exposure time, spatial resolution and density differentiation are given by the equipment specifications but have to be adapted to and optimised to the clinical problems involved in every case. Another important task is that of routine imaging of given anatomic structures, for adequate evaluation of individual conditions. (orig./MG) [de

  7. Investigation of parts and elements of technical reports in nuclear field in Japan

    International Nuclear Information System (INIS)

    Naramoto, Miyoko; Narui, Shigeko

    1985-01-01

    Presentation of parts and elements necessary for editing and publishing reports in accordance with SIST-09-1984 (Presentation of Scientific and Technical Reports) was investigated for 65 codes of technical reports in the nuclear field in Japan. English presentation of important elements was also investigated additionally. The investigation shows high presentation fractions (80 -- 100 %) for main bibliographic elements, and medium (66 %) and extremely low (3 %) for abntract and key word, respectively. (The bibliographic elements are described in various parts such as front cover, title page and front matter) and (the subject elements appear mainly in front matter). The title, author's name in Roman character, affiliation, publisher and abstract are described in English with fractions of 80 %, 66 %, 68 % and 62 %, respectively. It is hoped for more publishers and editors of technical reports to accept the standard SIST-09 for efficient processing of secondary information. (author)

  8. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  9. Technical universities beyond marketization: Educating the virtuous engineer

    NARCIS (Netherlands)

    Reijers, Wessel Hubert Maria

    2015-01-01

    In this paper, I argue that marketization trends affecting universities in general are strongly present in the management and education of technical universities. Partly, this is due to the historical background of the technical university as such, but marketization can nonetheless negatively affect

  10. Computed tomography in the diagnosis of pericardial heart disease

    International Nuclear Information System (INIS)

    Isner, J.M.; Carter, B.L.; Bankoff, M.S.; Konstam, M.A.; Salem, D.N.

    1982-01-01

    To evaluate the use of computed tomography (CT) in the diagnosis of pericardial heart disease, 53 patients were prospectively studied by computed tomography of the chest and cardiac ultrasound. A diagnostic-quality CT study was done for all patients; a technically satisfactory ultrasound examination was not possible in six patients. Of 47 patients in whom both chest scans and satisfactory ultrasound studies were obtained, computed tomography showed pericardial thickening not shown by ultrasound in five patients. Estimated size of pericardial effusion was the same for both computed tomography and ultrasound. Computed tomography provided quantifiable evaluation of the composition of pericardial fluid in seven patients with either hemopericardium or purulent pericarditis. Neoplastic pericardial heart disease was detected by CT scan in four of the 53 patients. Computed tomography of the chest provides a sensitive evaluation of the pericardium and quality of pericardial effusion, and is a valuable adjunct in patients in whom cardiac ultrasound is technically unsatisfactory

  11. Noncardiac findings on cardiac CT part I: Pros and cons.

    LENUS (Irish Health Repository)

    Killeen, Ronan P

    2012-02-01

    Cardiac computed tomography (CT) has evolved into an effective imaging technique for the evaluation of coronary artery disease in selected patients. Two distinct advantages over other noninvasive imaging modalities include its ability to evaluate directly the coronary arteries and to provide an opportunity to evaluate extracardiac structures, such as the lungs and mediastinum. Some centers reconstruct a small field of view (FOV) cropped around the heart, but a full FOV (from skin to skin in the irradiated area) is obtainable in the raw data of every scan so that clinically relevant noncardiac findings are identifiable. Debate in the scientific community has centered on the necessity for this large FOV evaluation. A review of noncardiac structures provides the opportunity to make alternative diagnoses that may account for the patient\\'s presentation or to detect important but clinically silent problems such as lung cancer. Critics argue that the yield of biopsy-proven cancers is low and that the follow-up of incidental noncardiac findings is expensive, resulting in increased radiation exposure and possibly unnecessary further testing. In this two-part review we outline the issues surrounding the concept of the noncardiac read looking for noncardiac findings on cardiac CT. Part I focuses on the pros and cons of the practice of identifying noncardiac findings on cardiac CT.

  12. Positron emission tomography imaging--technical considerations

    International Nuclear Information System (INIS)

    Muehllehner, G.; Karp, J.S.

    1986-01-01

    Positron imaging instrumentation has improved rapidly in the last few years. Scanners currently under development are beginning to approach fundamental limits set by positron range and noncolinearity effects. This report reviews the latest developments in positron emission tomography (PET) instrumentation, emphasizing the development of coding schemes that reduce the complexity and cost of high-resolution scanners. The relative benefits of using time-of-flight (TOF) information is discussed as well. 68 references

  13. Characteristics of the technical parameters in the realization of computed tomography studies in pediatric patients in Bogota

    International Nuclear Information System (INIS)

    Triana, Gustavo; Romero, Javier; Rivero, Oscar; Sosa, Daniel; Patarroyo, Edith

    2005-01-01

    The use of Computed Tomography (CT) examinations for the diagnosis of common pathologies in pediatric patients has increase. This implies an increase in the radiation doses that pediatric patients received, therefore increasing the risk of secondary mortality due to cancer throughout life. In recent papers, the recommended radiation doses for pediatric patients in agreement with the concept ALARA (As Low As Reasonably Achievable) has settled down. This study evaluates the CT technical parameters of pediatric examinations in Bogota city, and review if they have been fitted with parameters recommended according to age and body weight. Materials and methods: A non-probabilistic sampling of 46 scanning tests were applied to children in six different institutions in Bogota; the technical parameters of kv and second mAs were checked of studies in abdomen, thorax and skeletal muscle system. Results: It was found that the technical parameters used in TC in children are higher of the recommended; the group of 4-year-old is the most affected by dos e of unnecessary radiation. Discussion and conclusions: The information from the protection of the radiation must be spread to the whole radiology personnel of the institutions that fulfill scanning tests of pediatric patients. ar zones that influences the wetland

  14. Technical report on LWR design decision methodology. Phase I

    International Nuclear Information System (INIS)

    1980-03-01

    Energy Incorporated (EI) was selected by Sandia Laboratories to develop and test on LWR design decision methodology. Contract Number 42-4229 provided funding for Phase I of this work. This technical report on LWR design decision methodology documents the activities performed under that contract. Phase I was a short-term effort to thoroughly review the curret LWR design decision process to assure complete understanding of current practices and to establish a well defined interface for development of initial quantitative design guidelines

  15. White Paper of the Society of Computed Body Tomography and Magnetic Resonance on Dual-Energy CT, Part 2: Radiation Dose and Iodine Sensitivity.

    Science.gov (United States)

    Foley, W Dennis; Shuman, William P; Siegel, Marilyn J; Sahani, Dushyant V; Boll, Daniel T; Bolus, David N; De Cecco, Carlo N; Kaza, Ravi K; Morgan, Desiree E; Schoepf, U Joseph; Vrtiska, Terri J; Yeh, Benjamin M; Berland, Lincoln L

    This is the second of a series of 4 white papers that represent Expert Consensus Documents developed by the Society of Computed Body Tomography and Magnetic Resonance through its task force on dual-energy computed tomography. This paper, part 2, addresses radiation dose and iodine sensitivity in dual-energy computed tomography.

  16. Feasibility study for mega-electron-volt electron beam tomography.

    Science.gov (United States)

    Hampel, U; Bärtling, Y; Hoppe, D; Kuksanov, N; Fadeev, S; Salimov, R

    2012-09-01

    Electron beam tomography is a promising imaging modality for the study of fast technical processes. But for many technical objects of interest x rays of several hundreds of keV energy are required to achieve sufficient material penetration. In this article we report on a feasibility study for fast electron beam computed tomography with a 1 MeV electron beam. The experimental setup comprises an electrostatic accelerator with beam optics, transmission target, and a single x-ray detector. We employed an inverse fan-beam tomography approach with radiographic projections being generated from the linearly moving x-ray source. Angular projections were obtained by rotating the object.

  17. Tomography in nuclear medicine

    International Nuclear Information System (INIS)

    Levi de Cabrejas, Mariana

    1999-01-01

    This book is a contribution to the training and diffusion of the tomography method image diagnosis in nuclear medicine, which principal purpose is the information to professionals and technical personnel, specially for the spanish speaking staff

  18. Computed tomography and magnetic resonance imaging contrast media injectors: technical feature review – what is really needed?

    Directory of Open Access Journals (Sweden)

    Friebe M

    2016-07-01

    Full Text Available Michael Friebe Institute of Medical Engineering, Otto-von-Guericke-University, Magdeburg, Germany Abstract: There has been little technical innovation over the last few years for contrast media (CM injectors that are used for diagnostic imaging (computed tomography [CT], magnetic resonance imaging [MRI], and hybrid imaging systems, such as positron emission tomography–CT or magnetic resonance–positron emission tomography examinations. The medical need of CM for the enhancement of diagnostic images has been around for a long time, but the application of the CM into the blood stream comes with potential medical complications for the patient and requires a lot of operator experience and training. Most power injector systems that are currently used can do significantly more than what is typically required; this complexity however, adds error potential and cost. This paper focuses on the main features that CM injector systems should have and highlights the technical developments that are useful to have but which add complexity and cost, increase setup time, and require intensive training for safe use. CM injection protocols are very different between CT and MRI, with CT requiring many more variances, has a need for multiphase protocols, and requires a higher timing accuracy. A CM injector used in the MRI suite, on the other-hand, could only need a relatively time insensitive injection with a standard injection flow rate and a volume that is dependent on the patients’ weight. This would make easy and lightweight systems possible, which are able to safely and accurately perform the injection task, while allowing full MRI compatibility with relatively low cost investment and consumable costs. Keywords: power injector, contrast media injection, injection protocols, MRI compatibility

  19. C-arm Cone Beam Computed Tomography: A New Tool in the Interventional Suite.

    Science.gov (United States)

    Raj, Santhosh; Irani, Farah Gillan; Tay, Kiang Hiong; Tan, Bien Soo

    2013-11-01

    C-arm Cone Beam CT (CBCT) is a technology that is being integrated into many of the newer angiography systems in the interventional suite. Due to its ability to provide cross sectional imaging, it has opened a myriad of opportunities for creating new clinical applications. We review the technical aspects, current reported clinical applications and potential benefits of this technology. Searches were made via PubMed using the string "CBCT", "Cone Beam CT", "Cone Beam Computed Tomography" and "C-arm Cone Beam Computed Tomography". All relevant articles in the results were reviewed. CBCT clinical applications have been reported in both vascular and non-vascular interventions. They encompass many aspects of a procedure including preprocedural planning, intraprocedural guidance and postprocedural assessment. As a result, they have allowed the interventionalist to be safer and more accurate in performing image guided procedures. There are however several technical limitations. The quality of images produced is not comparable to conventional computed tomography (CT). Radiation doses are also difficult to quantify when compared to CT and fluoroscopy. CBCT technology in the interventional suite has contributed significant benefits to the patient despite its current limitations. It is a tool that will evolve and potentially become an integral part of imaging guidance for intervention.

  20. Digital radiography in tomography of the facial part of the skull

    International Nuclear Information System (INIS)

    Ibing, H.P.; Vogel, H.; Biebesheimer, V.

    1988-01-01

    In 14 patients the X-ray findings of dental, mandibulary and maxillary roentgen diagnosis were compared with conventional tomography and tomography by digital radiography. All details important for diagnosis were shown by both techniques. Tomography by digital radiography offered a more convenient approach and pictures easier to be interpreted than pictures by conventional tomography. (orig.) [de

  1. Magnetic resonance imaging of the elbow. Part I: Normal anatomy, imaging technique, and osseous abnormalities

    International Nuclear Information System (INIS)

    Kijowski, Richard; Tuite, Michael; Sanford, Matthew

    2004-01-01

    Part I of this comprehensive review on magnetic resonance imaging of the elbow discusses normal elbow anatomy and the technical factors involved in obtaining high-quality magnetic resonance images of the elbow. Part I also discusses the role of magnetic resonance imaging in evaluating patients with osseous abnormalities of the elbow. With proper patient positioning and imaging technique, magnetic resonance imaging can yield high-quality multiplanar images which are useful in evaluating the osseous structures of the elbow. Magnetic resonance imaging can detect early osteochondritis dissecans of the capitellum and can be used to evaluate the size, location, stability, and viability of the osteochondritis dissecans fragment. Magnetic resonance imaging can detect early stress injury to the proximal ulna in athletes. Magnetic resonance imaging can detect radiographically occult fractures of the elbow in both children and adults. Magnetic resonance imaging is also useful in children to further evaluate elbow fractures which are detected on plain-film radiographs. (orig.)

  2. Early positron emission tomography response-adapted treatment in stage I and II hodgkin lymphoma

    DEFF Research Database (Denmark)

    André, Marc P.E.; Girinsky, Théodore; Federico, Massimo

    2017-01-01

    Purpose Patients who receive combined modality treatment for stage I and II Hodgkin lymphoma (HL) have an excellent outcome. Early response evaluation with positron emission tomography (PET) scan may improve selection of patients who need reduced or more intensive treatments. Methods We performed...

  3. 123I-IMP single photon emission computed tomography (SPECT) study in childhood epilepsy

    International Nuclear Information System (INIS)

    Hara, Masafumi; Shimomura, Osamu; Kojima, Akihiro; Izunaga, Hiroshi; Tomiguchi, Seiji; Hirota, Yoshihisa; Taku, Keiichi; Miike, Teruhisa; Takahashi, Mutsumasa

    1990-01-01

    N-isopropyl-p[ 123 I]-iodoamphetamine (IMP) single photon emission computed tomography (SPECT), X-ray computed tomography (X-CT) and magnetic resonance imaging (MRI) were performed in 18 children with idiopathic seizures. In children with idiopathic seizures SPECT identified abnormal lesions in the highest rate (50%) compared with X-CT (11%) and MRI (13%), but the findings of SPECT poorly correlated with the foci on electroencephalography (EEG). Idiopathic epilepsy with abnormal uptake on SPECT was refractory to medical treatments and frequently associated with mental and/or developmental retardation. Perfusion defects identified on SPECT probably influenced the development of the brains in children. IMP SPECT is useful in the diagnosis and medical treatment in children with seizures. (author)

  4. Teaching Technical Writing - Towards Technical Writing

    DEFF Research Database (Denmark)

    Kastberg, Peter

    2000-01-01

    In this paper I will present key aspects of the curriculum for the university degree in technical translation that I have designed for and subsequently implemented at the German Department of the Aarhus School of Business, Denmark. My starting point will be a critical discussion of the norm that ...... of technical writing.......In this paper I will present key aspects of the curriculum for the university degree in technical translation that I have designed for and subsequently implemented at the German Department of the Aarhus School of Business, Denmark. My starting point will be a critical discussion of the norm...... that used to govern what the quality of an LSP text should be as opposed to the standpoint, which I advocate. By way of summing up, I will show how a university curriculum is designed so that - upon graduation - the technical translator could also be methodological quite well suited to take on the challenge...

  5. Lower extremity computed tomography angiography can help predict technical success of endovascular revascularization in the superficial femoral and popliteal artery.

    Science.gov (United States)

    Itoga, Nathan K; Kim, Tanner; Sailer, Anna M; Fleischmann, Dominik; Mell, Matthew W

    2017-09-01

    Preprocedural computed tomography angiography (CTA) assists in evaluating vascular morphology and disease distribution and in treatment planning for patients with lower extremity peripheral artery disease (PAD). The aim of the study was to determine the predictive value of radiographic findings on CTA and technical success of endovascular revascularization of occlusions in the superficial femoral artery-popliteal (SFA-pop) region. Medical records and available imaging studies were reviewed for patients undergoing endovascular intervention for PAD between January 2013 and December 2015 at a single academic institution. Radiologists reviewed preoperative CTA scans of patients with occlusions in the SFA-pop region. Radiographic criteria previously used to evaluate chronic occlusions in the coronary arteries were used. Technical success, defined as restoration of inline flow through the SFA-pop region with technical failure (P = .014). Longer lengths of occlusion were also associated with technical failure (P = .042). Multiple occlusions (P = .55), negative remodeling (P = .69), vessel runoff (P = .56), and percentage of vessel calcification (P = .059) were not associated with failure. On multivariable analysis, 100% calcification remained the only significant predictor of technical failure (odds ratio, 9.0; 95% confidence interval, 1.8-45.8; P = .008). Analysis of preoperative CTA shows 100% calcification as the best predictor of technical failure of endovascular revascularization of occlusions in the SFA-pop region. Further studies are needed to determine the cost-effectiveness of obtaining preoperative CTA for lower extremity PAD. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  6. Technical realisation of the VISA-3 project, Parts I-II, Part I; Tehnicka realizacija projekta VISA-3, I-II deo, I Deo

    Energy Technology Data Exchange (ETDEWEB)

    Pavicevic, M; Smokovic, Z [Institute of Nuclear Sciences Boris Kidric, Odeljenje za reaktorsku eksperimentalnu tehniku, Vinca, Beograd (Serbia and Montenegro)

    1966-11-15

    This task is related to irradiation of reactor materials (steel, Al, MgO, Al{sub 2}O{sub 3}, ets.) at higher temperatures (200-500 deg C) in the fast neutron flux. These conditions would be more realistic to real reactor conditions than the conditions achieved within VISA-2 project. The experimental space will be the same as in VISA-2 project, i.e. refurbished reactor channels and within the fuel elements. The irradiation capsule will be leak tight with thermal isolation layer and supplied with electric heater to enable temperature variation.

  7. Towards automated diffraction tomography. Part II-Cell parameter determination

    International Nuclear Information System (INIS)

    Kolb, U.; Gorelik, T.; Otten, M.T.

    2008-01-01

    Automated diffraction tomography (ADT) allows the collection of three-dimensional (3d) diffraction data sets from crystals down to a size of only few nanometres. Imaging is done in STEM mode, and diffraction data are collected with quasi-parallel beam nanoelectron diffraction (NED). Here, we present a set of developed processing steps necessary for automatic unit-cell parameter determination from the collected 3d diffraction data. Cell parameter determination is done via extraction of peak positions from a recorded data set (called the data reduction path) followed by subsequent cluster analysis of difference vectors. The procedure of lattice parameter determination is presented in detail for a beam-sensitive organic material. Independently, we demonstrate a potential (called the full integration path) based on 3d reconstruction of the reciprocal space visualising special structural features of materials such as partial disorder. Furthermore, we describe new features implemented into the acquisition part

  8. Monographs in Tang Official Historiography: Perspectives from the Technical Treatises of the <i>History of Suii> <i>(>Sui shu<i>)>

    OpenAIRE

    Morgan, Daniel Patrick; Chaussende, Damien

    2018-01-01

    Finished in 656 as part of a larger project, the ten ‘treatises’ (zhi) of the current History of Sui (Sui shu) provide us with histories of such fields of technical knowledge as astronomy, astrology, omenology, economics, law, geography, metrology, and library science covering the five divided and short-lived dynasties, 502–618 CE, that were the predecessors of the Tang. This edited volume brings together young experts in these fields to reflect upon the way that their history has been writte...

  9. Single-photon emission tomography (SPECT) with 123I-amphetamine in cerebral ischemia

    International Nuclear Information System (INIS)

    Koenig, B.; Donis, J.; Mostbeck, A.; Koehn, H.

    1987-01-01

    The uptake of 123 I-amphetamine (IMP) in brain mainly corresponds to regional perfusion. Distribution of IMP can be visualized in tomographic slices by single-photon emission computed tomography (SPECT). For better evaluation and comparison in follow-up studies, right/left ratios were computed and an asymmetry index calculated. The most sensitive asymmetry index was achieved by 120 average circumferential profiles. In 52 patients with stroke and 16 controls the respective sensitivities of IMP-SPECT, computed tomography (CT), static and dynamic brain scanning and angiography were evaluated. In patients with TIA and PRIND the IMP-SPECT had the highest sensitivity of all non-invasive methods. In patients with completed stroke, the sensitivity of IMP-SPECT was comparable with that of CT (90 vs. 93%). There was a significant correlation between the IMP asymmetry index and the clinical and social score (p [de

  10. Advances in cryo-electron tomography for biology and medicine.

    Science.gov (United States)

    Koning, Roman I; Koster, Abraham J; Sharp, Thomas H

    2018-05-01

    Cryo-electron tomography (CET) utilizes a combination of specimen cryo-fixation and multi-angle electron microscopy imaging to produce three-dimensional (3D) volume reconstructions of native-state macromolecular and subcellular biological structures with nanometer-scale resolution. In recent years, cryo-electron microscopy (cryoEM) has experienced a dramatic increase in the attainable resolution of 3D reconstructions, resulting from technical improvements of electron microscopes, improved detector sensitivity, the implementation of phase plates, automated data acquisition schemes, and improved image reconstruction software and hardware. These developments also greatly increased the usability and applicability of CET as a diagnostic and research tool, which is now enabling structural biologists to determine the structure of proteins in their native cellular environment to sub-nanometer resolution. These recent technical developments have stimulated us to update on our previous review (Koning, R.I., Koster, A.J., 2009. Cryo-electron tomography in biology and medicine. Ann Anat 191, 427-445) in which we described the fundamentals of CET. In this follow-up, we extend this basic description in order to explain the aforementioned recent advances, and describe related 3D techniques that can be applied to the anatomy of biological systems that are relevant for medicine. Copyright © 2018 Elsevier GmbH. All rights reserved.

  11. Workshop 95. Part I

    International Nuclear Information System (INIS)

    1995-12-01

    The proceedings of the seminar contain more than 420 contributions divided into 21 areas of interest. In Part I, 144 contributions are presented from the following fields: mathematics, physics, chemistry, engineering informatics and cybernetics, computer art, and fluid mechanics. For input in INIS, 15 contributions were selected from the physics section and 1 from the chemistry section. (J.B.)

  12. Workshop 95. Part I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The proceedings of the seminar contain more than 420 contributions divided into 21 areas of interest. In Part I, 144 contributions are presented from the following fields: mathematics, physics, chemistry, engineering informatics and cybernetics, computer art, and fluid mechanics. For input in INIS, 15 contributions were selected from the physics section and 1 from the chemistry section. (J.B.).

  13. International Linear Collider Technical Design Report (Volumes 1 through 4)

    Energy Technology Data Exchange (ETDEWEB)

    Harrison M.

    2013-03-27

    The design report consists of four volumes: Volume 1, Executive Summary; Volume 2, Physics; Volume 3, Accelerator (Part I, R and D in the Technical Design Phase, and Part II, Baseline Design); and Volume 4, Detectors.

  14. Review of the technical bases of 40 CFR Part 190.

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, John E.; McMahon, Kevin A.; Siegel, Malcolm Dean; Weiner, Ruth F.; Bixler, Nathan E.; Klein, Keith A. (Longenecker and Associates)

    2010-07-01

    The dose limits for emissions from the nuclear fuel cycle were established by the Environmental Protection Agency in 40 CFR Part 190 in 1977. These limits were based on assumptions regarding the growth of nuclear power and the technical capabilities of decontamination systems as well as the then-current knowledge of atmospheric dispersion and the biological effects of ionizing radiation. In the more than thirty years since the adoption of the limits, much has changed with respect to the scale of nuclear energy deployment in the United States and the scientific knowledge associated with modeling health effects from radioactivity release. Sandia National Laboratories conducted a study to examine and understand the methodologies and technical bases of 40 CFR 190 and also to determine if the conclusions of the earlier work would be different today given the current projected growth of nuclear power and the advances in scientific understanding. This report documents the results of that work.

  15. Technical competence in cardiovascular magnetic resonance and computed tomography; Competencia tecnica em ressonancia e tomografia cardiovascular

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Juliano Lara; Shiozaki, Afonso Akio; Azevedo Filho, Clerio Francisco de; Rochitte, Carlos Eduardo; Pinto, Ibraim Marciarelli Francisco; Lopes, Marly Maria Uellendahl; Schvartzman, Paulo Roberto, E-mail: jlaraf@fcm.unicamp.br [Universidade de Campinas (UNICAMP/GERT) SP (Brazil). Grupo de Estudo em Ressonancia e Tomografia Cardiovascular

    2009-10-15

    Cardiovascular magnetic resonance and computed tomography have evolved as very practical and useful techniques applied in clinical cardiology. Due to their rapid acceptance in the cardiology community and widespread use, training of both cardiologists and radiologists on this subspecialty has not been homogeneous so far. This in part explains significant differences observed in the diverse background found in today’s practicing physicians who execute these exams. In order to guide training facilities as well as both payers, contractors and general cardiologists ordering the exam, this document provides a minimum standard that should be accomplished by all physicians who pursue education in the field and for those who already practice in it. The clinical competences listed in this statement are by no means thorough but should be required by all those involved in cardiovascular magnetic resonance and computed tomography as the customary requirements for current and future practitioners. (author)

  16. Myocardial blood flow quantification for evaluation of coronary artery disease by positron emission tomography, cardiac magnetic resonance imaging, and computed tomography.

    Science.gov (United States)

    Waller, Alfonso H; Blankstein, Ron; Kwong, Raymond Y; Di Carli, Marcelo F

    2014-05-01

    The noninvasive detection of the presence and functional significance of coronary artery stenosis is important in the diagnosis, risk assessment, and management of patients with known or suspected coronary artery disease. Quantitative assessment of myocardial perfusion can provide an objective and reproducible estimate of myocardial ischemia and risk prediction. Positron emission tomography, cardiac magnetic resonance, and cardiac computed tomography perfusion are modalities capable of measuring myocardial blood flow and coronary flow reserve. In this review, we will discuss the technical aspects of quantitative myocardial perfusion imaging with positron emission tomography, cardiac magnetic resonance imaging, and computed tomography, and its emerging clinical applications.

  17. LINAG phase I. A technical report, Version: 1.3

    International Nuclear Information System (INIS)

    Mittig, Wolfgang

    2002-01-01

    In a first report the possibility of a high intensity accelerator at GANIL, producing secondary beams of unprecedented intensity, was considered. As was outlined in that report, LINAG I, a low energy high intensity linear accelerator constituting a first phase of this more general project, could produce secondary beams either from fission products, or from fusion-evaporation or deep inelastic reactions. The Scientific Council and Directors of GANIL recommended a more detailed technical study of LINAG I as a possible option for the SPIRAL II project, to be compared to the photofission option. This is the objective of the present report. In this project, fission induced by light particles (e, p, d, etc...) is proposed to produce the radioactive ions, with an aim of 10 13 fissions/s at least, with and without a converter (an intermediate target for producing high fluxes of neutrons). The technical aspects of the LINAG I projects are studied. The LINAG I project could be considered as being part of a multi-beam policy of GANIL. It is shown that many possibilities of simultaneous use of beams would be considered. Possible synergies with EURISOL are underlined; LINAG could very well be a first phase of EURISOL and could easily provide a ready-made post-accelerator for this European project. It would also provide useful experience in operating an accelerator with up to 5 μA beams, and with beams of much higher power than those presently available at SPIRAL. Radiation shielding and safe handling of radioactive components and safe disposal of radioactive waste materials and by-products (such as gases) will be an extremely important factor in obtaining permission to operate a facility such as LINAG or EURISOL. Even though the EURISOL proposal is concerned with MW beam power, the experience with the 360 kW beams proposed by LINAG would be very relevant. The report has the following structure: I. Introduction; II. Production of Radioactive Ion Beams, RIB, and ISOL; II.1

  18. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  19. Workshop 96. Part I

    International Nuclear Information System (INIS)

    1995-12-01

    The proceedings of the seminar contain nearly 500 contributions divided into 22 fields of science and technology. In Part I, 167 contributions are presented in the following areas: mathematics, physics, chemistry, engineering informatics and cybernetics, computers, and fluid mechanics. For input in INIS, 19 contributions were selected from the Physics section, 2 from the Mathematics section, and 4 from the Chemistry section. (P.A.)

  20. Workshop 96. Part I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The proceedings of the seminar contain nearly 500 contributions divided into 22 fields of science and technology. In Part I, 167 contributions are presented in the following areas: mathematics, physics, chemistry, engineering informatics and cybernetics, computers, and fluid mechanics. For input in INIS, 19 contributions were selected from the Physics section, 2 from the Mathematics section, and 4 from the Chemistry section. (P.A.).

  1. Assessment of color quality and energy effciency : new insights for modern lighting. Part I : color quality in general lighting applications. Part II : mesopic photometry and street lighting

    OpenAIRE

    Quintero, Jesús M.

    2015-01-01

    Cotutela Universitat Politècnica de Catalunya i Institut de Recerca en Energia de Catalunya. La consulta íntegra de la tesi, inclosos els articles no comunicats públicament per drets d'autor, es pot realitzar, prèvia petició, a l'Arxiu de la UPC This dissertation is divided in two parts: The first one deal with two main characteristics of the light sources for general lighting: Color quality and luminous efficacy. The second one deals with technical aspects of the mesopic photometry appli...

  2. Integrated Basic Education and Skills Training (I-BEST). Washington's Community and Technical Colleges

    Science.gov (United States)

    Washington State Board for Community and Technical Colleges, 2014

    2014-01-01

    Washington's Integrated Basic Education and Skills Training Program (I-BEST) quickly teaches students literacy, work, and college-readiness skills so they can move through school and into living wage jobs faster. Pioneered by Washington's community and technical colleges, I-BEST uses a team-teaching approach to combine college-readiness classes…

  3. White Paper of the Society of Computed Body Tomography and Magnetic Resonance on Dual-Energy CT, Part 1: Technology and Terminology.

    Science.gov (United States)

    Siegel, Marilyn J; Kaza, Ravi K; Bolus, David N; Boll, Daniel T; Rofsky, Neil M; De Cecco, Carlo N; Foley, W Dennis; Morgan, Desiree E; Schoepf, U Joseph; Sahani, Dushyant V; Shuman, William P; Vrtiska, Terri J; Yeh, Benjamin M; Berland, Lincoln L

    This is the first of a series of 4 white papers that represent Expert Consensus Documents developed by the Society of Computed Body Tomography and Magnetic Resonance through its task force on dual-energy computed tomography (DECT). This article, part 1, describes the fundamentals of the physical basis for DECT and the technology of DECT and proposes uniform nomenclature to account for differences in proprietary terms among manufacturers.

  4. Technical Training: CERN Technical Training 2004: <i>Instructor-led WBTechT Course for Microsoft Applicationsi>

    CERN Multimedia

    2004-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch Would you need to enhance your skills in Microsoft Office applications or Outlook ? A new "blended learning" course, combining instructor-led and computer-based multimedia training, is now offered by Technical Training: the Instructor-led CERN Web-Based Technical Training course for Microsoft Applications. The next session will take place on February 26, Thursday morning. Course sessions will be self-paced and self-directed, with participants being in control of their learning, while ...

  5. Technical Training: CERN Technical Training 2004: <i>Instructor-led WBTechT Course for Microsoft Applicationsi>

    CERN Multimedia

    2004-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch Would you need to enhance your skills in Microsoft Office applications or Outlook ? A new "blended learning" course, combining instructor-led and computer-based multimedia training, is now offered by Technical Training: the Instructor-led CERN Web-Based Technical Training course for Microsoft Applications. The next sessions will take place on the 19 and 26 February (Thursday mornings), with 8 participants at most. Course sessions will be self-paced and self-directed, with participants...

  6. Technical co-operation report for 1998. Report by the Director General

    International Nuclear Information System (INIS)

    1999-01-01

    This report presents the IAEA Technical Co-operation (TC) activities during 1998 and highlights most significant accomplishments. Part I of this report reviews the strengthening of TC, both in financial aspects and through implementation of the TC strategy. Part II reviews extensively the actual output of the TC programme; it looks at each geographic region, and reports on the results of national, regional and, where applicable, interregional activities in those regions. Part III presents a technical discussion of the financial parameters of the TC programme and ends with financial implementation summaries

  7. Technical co-operation report for 1998. Report by the Director General

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    This report presents the IAEA Technical Co-operation (TC) activities during 1998 and highlights most significant accomplishments. Part I of this report reviews the strengthening of TC, both in financial aspects and through implementation of the TC strategy. Part II reviews extensively the actual output of the TC programme; it looks at each geographic region, and reports on the results of national, regional and, where applicable, interregional activities in those regions. Part III presents a technical discussion of the financial parameters of the TC programme and ends with financial implementation summaries.

  8. 12 CFR Appendices F-I to Part 41 - [Reserved

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false [Reserved] F Appendices F-I to Part 41 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY FAIR CREDIT REPORTING Appendices F-I to Part 41[Reserved] ...

  9. Synchrotron X-ray CT characterization of titanium parts fabricated by additive manufacturing. Part I. Morphology.

    Science.gov (United States)

    Scarlett, Nicola Vivienne Yorke; Tyson, Peter; Fraser, Darren; Mayo, Sheridan; Maksimenko, Anton

    2016-07-01

    Synchrotron X-ray tomography has been applied to the study of titanium parts fabricated by additive manufacturing (AM). The AM method employed here was the Arcam EBM(®) (electron beam melting) process which uses powdered titanium alloy, Ti64 (Ti alloy with approximately 6%Al and 4%V), as the feed and an electron beam for the sintering/welding. The experiment was conducted on the Imaging and Medical Beamline of the Australian Synchrotron. Samples were chosen to examine the effect of build direction and complexity of design on the surface morphology and final dimensions of the piece.

  10. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  11. 6-[F-18]Fluoro-L-Dihydroxyphenylalanine Positron Emission Tomography Is Superior to Conventional Imaging with I-123-Metaiodobenzylguanidine Scintigraphy, Computer Tomography, and Magnetic Resonance Imaging in Localizing Tumors Causing Catecholamine Excess

    NARCIS (Netherlands)

    Fiebrich, Helle-Brit; Brouwers, Adrienne H.; Kerstens, Michiel N.; Pijl, Milan E. J.; Kema, Ido P.; de Jong, Johan R.; Jager, Pieter L.; Elsinga, Philip H.; Dierckx, Rudi A. J. O.; van der Wal, Jacqueline E.; Sluiter, Wim J.; de Vries, Elisabeth G. E.; Links, Thera P.

    2009-01-01

    Context: Catecholamine excess is rare, but symptoms may be life threatening. Objective: The objective of the study was to investigate the sensitivity of 6-[F-18]fluoro-L-dihydroxyphenylalanine positron emission tomography (F-18-DOPAPET), compared with I-123-metaiodobenzylguanidine (I-123-MIBG)

  12. Applications of technical fusion in uroradiology

    International Nuclear Information System (INIS)

    Aigner, F.; Zordo, T. de; Junker, D.; Pallwein-Prettner, L.

    2015-01-01

    Technical fusion is defined as the ultrasound-guided navigation through a previously generated 3 D imaging dataset such as a computed tomography (CT) or magnetic resonance imaging (MRI). This technique allows for moving the fused CT/MRI datasets synchroneously with the real-time ultrasound in the same plane. Established and furthermore not yet described applications, the technical principles and the limitations of this promising technique will be introduced.

  13. Computerized tomography. Fundamentals, equipment, image quality, applications. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Kalender, W.A.

    2006-01-01

    The book provides a clear and user-oriented outline of the theoretical and technical fundamentals of computerized tomography for a wide range of readers, from conventional CT to volume CT with conical beams. Image quality, its relevant influencing parameters and the performance factors to be observed for clinical application are discussed in detail, as are dose requirements, dose metering and dose reduction measures in CT. The second, revised edition contains updated information and also presents new technologies. A CD-ROM with attractive exemplary appications, animations and interactive exercises in image interpretation and manipulation is included. The book addresses everyone concerned with CT, either in their daily routine or even only every now and then, i.e. physicians, medical assistants, engineers, technicians and physicists. The book also contains a glossary of technical terms. (orig.)

  14. 10 CFR Appendix III to Part 960 - Application of the System and Technical Guidelines During the Siting Process

    Science.gov (United States)

    2010-01-01

    ... 960—Application of the System and Technical Guidelines During the Siting Process 1. This appendix... 10 Energy 4 2010-01-01 2010-01-01 false Application of the System and Technical Guidelines During the Siting Process III Appendix III to Part 960 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE...

  15. Function Concepts for Machine Parts

    DEFF Research Database (Denmark)

    Mortensen, Niels Henrik

    1999-01-01

    The majority of resources, like time and costs, consumed in industrial product development can be related to detailed design, i.e. the materialisation of machine parts (German Maschinenteile). Existing design theories based on a systems approach, e.g. Haberfellner [5] all have function, i.......e. transformation from input to output or ability to deliver purposeful effects as the core concept. The units in a product which posses functions are the organs (German: Funktionsträgern). Because individual parts do not posses functions, one could argue that the design theories based on a systems approach...... to be identification of a purposeful behaviour concept, i.e. function for a machine part. The contribution is based on the theory of technical systems, Hubka and the domain theory, Andreasen....

  16. Interaction of complexes I, III, and IV within the bovine respirasome by single particle cryoelectron tomography

    NARCIS (Netherlands)

    Dudkina, Natalya V.; Kudryashev, Mikhail; Stahlberg, Henning; Boekema, Egbert J.

    2011-01-01

    The respirasome is a multisubunit supercomplex of the respiratory chain in mitochondria. Here we report the 3D reconstruction of the bovine heart respirasome, composed of dimeric complex III and single copies of complex I and IV, at about 2.2-nm resolution, determined by cryoelectron tomography and

  17. Density evaluation by computerized tomography in plain soils over different manipulation systems

    International Nuclear Information System (INIS)

    Pedrotti, Alceu

    1996-08-01

    The objective of this paper is the evaluation of a plain soil density in different culture systems determined by X ray computerized tomography.It was observed a larger variation in densities in soils profiles analysed. The identification of layers is better utilising computerized tomography than others technic

  18. Power source roadmaps using bibliometrics and database tomography

    International Nuclear Information System (INIS)

    Kostoff, R.N.; Tshiteya, R.; Pfeil, K.M.; Humenik, J.A.; Karypis, G.

    2005-01-01

    Database Tomography (DT) is a textual database analysis system consisting of two major components: (1) algorithms for extracting multi-word phrase frequencies and phrase proximities (physical closeness of the multi-word technical phrases) from any type of large textual database, to augment (2) interpretative capabilities of the expert human analyst. DT was used to derive technical intelligence from a Power Sources database derived from the Science Citation Index. Phrase frequency analysis by the technical domain experts provided the pervasive technical themes of the Power Sources database, and the phrase proximity analysis provided the relationships among the pervasive technical themes. Bibliometric analysis of the Power Sources literature supplemented the DT results with author/journal/institution/country publication and citation data

  19. Dynamic Optical Coherence Tomography in Dermatology

    DEFF Research Database (Denmark)

    Ulrich, Martina; Themstrup, Lotte; De Carvalho, Nathalie

    2016-01-01

    Optical coherence tomography (OCT) represents a non-invasive imaging technology, which may be applied to the diagnosis of non-melanoma skin cancer and which has recently been shown to improve the diagnostic accuracy of basal cell carcinoma. Technical developments of OCT continue to expand the app...

  20. Standards in neurosonology. Part I

    Directory of Open Access Journals (Sweden)

    Joanna Wojcza

    2015-09-01

    Full Text Available The paper presents standards related to ultrasound imaging of the cerebral vasculature and structures. The aim of this paper is to standardize both the performance and description of ultrasound imaging of the extracranial and intracranial cerebral arteries as well as a study of a specifi c brain structure, i.e. substantia nigra hyperechogenicity. The following aspects are included in the description of standards for each ultrasonographic method: equipment requirements, patient preparation, study technique and documentation as well as the required elements of ultrasound description. Practical criteria for the diagnosis of certain pathologies in accordance with the latest literature were also presented. Furthermore, additional comments were included in some of the sections. Part I discusses standards for the performance, documentation and description of different ultrasound methods (Duplex, Doppler. Part II and III are devoted to standards for specifi c clinical situations (vasospasm, monitoring after the acute stage of stroke, detection of a right-toleft shunts, confi rmation of the arrest of the cerebral circulation, an assessment of the functional effi ciency of circle of Willis, an assessment of the cerebrovascular vasomotor reserve as well as the measurement of substantia nigra hyperechogenicity.

  1. McKenzie River Subbasin Assessment, Technical Report 2000.

    Energy Technology Data Exchange (ETDEWEB)

    Alsea Geospatial, Inc.

    2000-02-01

    This document details the findings of the McKenzie River Subbasin Assessment team. The goal of the subbasin assessment is to provide an ecological assessment of the McKenzie River Floodplain, identification of conservation and restoration opportunities, and discussion of the influence of some upstream actions and processes. This Technical Report can be viewed in conjunction with the McKenzie River Subbasin Summary or as a stand-alone document. The purpose of the technical report is to detail the methodology and findings of the consulting team that the observations and recommendations in the summary document are based on. This part, Part I, provides an introduction to the subbasin and a general overview. Part II details the specific findings of the science team. Part III provides an explanation and examples of how to use the data that has been developed through this assessment to aid in prioritizing restoration activities. Part III also includes the literature cited and appendices.

  2. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  3. Taxonomy of Means and Ends in Aquaculture Production—Part 2: The Technical Solutions of Controlling Solids, Dissolved Gasses and pH

    Directory of Open Access Journals (Sweden)

    Bjorgvin Vilbergsson

    2016-09-01

    Full Text Available In engineering design, knowing the relationship between the means (technique and the end (desired function or outcome is essential. The means in Aquaculture are technical solutions like airlifts that are used to achive desired functionality (an end like controlling dissolved gasses. In previous work, the authors identified possible functions by viewing aquaculture production systems as transformation processes in which inputs are transformed by treatment techniques (means and produce outputs (ends. The current work creates an overview of technical solutions of treatment functions for both design and research purposes. A comprehensive literature review of all areas of technical solutions is identified and categorized into a visual taxonomy of the treatment functions for controlling solids, controlling dissolved gasses and controlling pH alkalinity and hardness. This article is the second in a sequence of four and partly presents the treatments functions in the taxonomy. The other articles in this series present complementary aspects of this research: Part 1, A transformational view on aquaculture and functions divided into input, treatment and output functions; Part 2, The current taxonomy paper; Part 3, The second part of the taxonomy; and Part 4, Mapping of the means (techniques for multiple treatment functions.

  4. Formative evaluation of a telemedicine model for delivering clinical neurophysiology services part I: utility, technical performance and service provider perspective.

    LENUS (Irish Health Repository)

    Breen, Patricia

    2010-01-01

    Formative evaluation is conducted in the early stages of system implementation to assess how it works in practice and to identify opportunities for improving technical and process performance. A formative evaluation of a teleneurophysiology service was conducted to examine its technical and sociological dimensions.

  5. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  6. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  7. Technical Training: CERN Technical Training 2004: <i>Instructor-led WBTechT Course for Microsoft Applicationsi>

    CERN Multimedia

    2004-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch The Instructor-led CERN WBTechT course for Microsoft Applications is a new type of course offered in the framework of the Technical Training Programme, combining instructor-led and computer-based multimedia training, also known as "blended learning". The next sessions will take place on the 12, 19, and 26 February (Thursday mornings), and subsequent sessions will be organised following demand. Based on the new ElementK 2004 CERN WBTechT catalogue, courses will be self-paced and self-d...

  8. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  9. 46 CFR Appendix B to Subpart C to... - Substance Technical Guidelines, Benzene

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Substance Technical Guidelines, Benzene B Appendix B to... Subpart C to Part 197—Substance Technical Guidelines, Benzene I. Physical and Chemical Data (a) Substance... temperature: 580 °C (1076 °F). (3) Flammable limits in air, % by volume: Lower: 1.3%, Upper: 7.5%. (4...

  10. Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Verma, Shashwat; Kheruka, Subhash Chand; Maurya, Anil Kumar; Kumar, Narvesh; Gambhir, Sanjay; Kumari, Sarita

    2016-01-01

    Positron emission tomography has been established as an important imaging modality in the management of patients, especially in oncology. The higher gamma radiation energy of positron-emitting isotopes poses an additional radiation safety problem. Those working with this modality may likely to receive higher whole body doses than those working only in conventional nuclear medicine. The radiation exposure to the personnel occurs in dispensing the dose, administration of activity, patient positioning, and while removing the intravenous (i.v.) cannula. The estimation of radiation dose to Nuclear Medicine Physician (NMP) involved during administration of activity to the patient and technical staff assisting in these procedures in a positron emission tomography/computed tomography (PET/CT) facility was carried out. An i.v access was secured for the patient by putting the cannula and blood sugar was monitored. The activity was then dispensed and measured in the dose calibrator and administered to the patient by NMP. Personnel doses received by NMP and technical staff were measured using electronic pocket dosimeter. The radiation exposure levels at various working locations were assessed with the help of gamma survey meter. The radiation level at working distance while administering the radioactivity was found to be 106-170 μSv/h with a mean value of 126.5 ± 14.88 μSv/h which was reduced to 4.2-14.2 μSv/h with a mean value of 7.16 ± 2.29 μSv/h with introduction of L-bench for administration of radioactivity. This shows a mean exposure level reduction of 94.45 ± 1.03%. The radiation level at working distance, while removing the i.v. cannula postscanning was found to be 25-70 μSv/h with a mean value of 37.4 ± 13.16 μSv/h which was reduced to 1.0-5.0 μSv/h with a mean value of 2.77 ± 1.3 μSv/h with introduction of L-bench for removal of i.v cannula. This shows a mean exposure level reduction of 92.85 ± 1.78%. This study shows that good radiation practices are

  11. A comprehensive study of the use of temporal moments in time-resolved diffuse optical tomography: part I. Theoretical material

    Energy Technology Data Exchange (ETDEWEB)

    Ducros, Nicolas; Herve, Lionel; Dinten, Jean-Marc [CEA, LETI, MINATEC, 17 rue des Martyrs, F-38054 Grenoble (France); Da Silva, Anabela [Institut Fresnel, CNRS UMR 6133, Universite Aix-Marseille, Ecole Centrale Marseille, Campus universitaire de Saint-Jerome, F-13013 Marseille (France); Peyrin, Francoise [CREATIS, INSERM U 630, CNRS UMR 5220, Universite de Lyon, INSA de Lyon, bat. Blaise Pascal, F-69621 Villeurbanne Cedex (France)], E-mail: nicolas.ducros@cea.fr

    2009-12-07

    The problem of fluorescence diffuse optical tomography consists in localizing fluorescent markers from near-infrared light measurements. Among the different available acquisition modalities, the time-resolved modality is expected to provide measurements of richer information content. To extract this information, the moments of the time-resolved measurements are often considered. In this paper, a theoretical analysis of the moments of the forward problem in fluorescence diffuse optical tomography is proposed for the infinite medium geometry. The moments are expressed as a function of the source, detector and markers positions as well as the optical properties of the medium and markers. Here, for the first time, an analytical expression holding for any moments order is mathematically derived. In addition, analytical expressions of the mean, variance and covariance of the moments in the presence of noise are given. These expressions are used to demonstrate the increasing sensitivity of moments to noise. Finally, the newly derived expressions are illustrated by means of sensitivity maps. The physical interpretation of the analytical formulae in conjunction with their map representations could provide new insights into the analysis of the information content provided by moments.

  12. Rapid and efficient radiosynthesis of [123I]I-PK11195, a single photon emission computed tomography tracer for peripheral benzodiazepine receptors

    International Nuclear Information System (INIS)

    Pimlott, Sally L.; Stevenson, Louise; Wyper, David J.; Sutherland, Andrew

    2008-01-01

    Introduction: [ 123 I]I-PK11195 is a high-affinity single photon emission computed tomography radiotracer for peripheral benzodiazepine receptors that has previously been used to measure activated microglia and to assess neuroinflammation in the living human brain. This study investigates the radiosynthesis of [ 123 I]I-PK11195 in order to develop a rapid and efficient method that obtains [ 123 I]I-PK11195 with a high specific activity for in vivo animal and human imaging studies. Methods: The synthesis of [ 123 I]I-PK11195 was evaluated using a solid-state interhalogen exchange method and an electrophilic iododestannylation method, where bromine and trimethylstannyl derivatives were used as precursors, respectively. In the electrophilic iododestannylation method, the oxidants peracetic acid and chloramine-T were both investigated. Results: Electrophilic iododestannylation produced [ 123 I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than achievable using the halogen exchange method investigated. Using chloramine-T as oxidant provided a rapid and efficient method of choice for the synthesis of [ 123 I]I-PK11195. Conclusions: [ 123 I]I-PK11195 has been successfully synthesized via a rapid and efficient electrophilic iododestannylation method, producing [ 123 I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than previously achieved

  13. National Profiles in Technical and Vocational Education in Asia and the Pacific: Fiji.

    Science.gov (United States)

    United Nations Educational, Scientific and Cultural Organization, Bangkok (Thailand). Principal Regional Office for Asia and the Pacific.

    This technical and vocational education (TVE) profile on Fiji is one in a series of profiles of UNESCO member countries. It is intended to be a handy reference on TVE systems, staff development, technical cooperation, and information networking. Part I, General Information, covers the following: location, area, and physical features; economic and…

  14. National Profiles in Technical and Vocational Education in Asia and the Pacific: Bangladesh.

    Science.gov (United States)

    United Nations Educational, Scientific and Cultural Organization, Bangkok (Thailand). Principal Regional Office for Asia and the Pacific.

    This technical and vocational education (TVE) profile on Bangladesh is one in a series of profiles of UNESCO member countries. It is intended to be a handy reference on TVE systems, staff development, technical cooperation, and information networking. An overview of the report appears first. Part I provides general information on the physical…

  15. National Profiles in Technical and Vocational Education in Asia and the Pacific: Bhutan.

    Science.gov (United States)

    United Nations Educational, Scientific and Cultural Organization, Bangkok (Thailand). Principal Regional Office for Asia and the Pacific.

    This technical and vocational education (TVE) profile on Bhutan is one in a series of profiles of UNESCO member countries. It is intended to be a handy reference on TVE systems, staff development, technical cooperation, and information networking. Part I, Policy Concern, provides general information on the education delivery system, the role of…

  16. World Solar Challenge 1993 Technical Report. Part 1. Darwin to Adelaide. (November 7-November 16, 1993)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-01-01

    This is a report of the above-named solar car race from Darwin to Adelaide, Australia. On January 7, 1983, an Australian adventurer Mr. Hans Tholstrup succeeded in running from the Australian west coast to Sydney in a car driven solely by solar energy. The travel took 20 days, at an average speed of 23km per hour. The technology has made remarkable advances since his success and, in the World Solar Challenge 1993 held in November 1993, a Honda team crossed the Australian Continent at an average speed of 85km per hour. Technical challenges included the development of maximum-output solar cell panels, a car designed to make full use of such power, and a run at the maximum possible speed, all these dependent solely on the sun as energy source. This report Part I contains the details of the race, analysis, aerodynamics, car body structure, manufacture, materials, and so forth. (NEDO)

  17. Radiological assistance program: Region I. Part I

    International Nuclear Information System (INIS)

    Musolino, S.V.; Kuehner, A.V.; Hull, A.P.

    1985-01-01

    The purpose of the Radiological Assistance Program (RAP) is to make DOE resources available and provide emergency assistance to state and local agencies in order to control radiological hazards, protect the public health and safety, and minimize the loss of property. This plan is an integral part of a nationwide program of radiological assistance established by the US DOE, and is implemented on a regional basis. The Brookhaven Area Office (BHO) Radiological Assistance Program is applicable to DOE Region I, which consists of the New England States, New York, New Jersey, Pennsylvania, Delaware, Maryland and the District of Columbia. The BHO RAP-1 has been developed to: (a) ensure the availability of an effective radiological assistance capability to ensure the protection of persons and property; (b) provide guidelines to RAP-1 Team personnel for the evaluation of radiological incidents and implementation of corrective actions; (c) maintain liaison with other DOE installations, Federal, State and local organizations which may become involved in radiological assistance operations in Region I; and (d) encourage development of a local capability to cope with radiological incidents

  18. Computerized tomography in Community of Madrid. Reference dosimetric measurements

    International Nuclear Information System (INIS)

    Ruiz Sanz, S.; Calzado, A.; Melchor, M.; Marco, M.

    1994-01-01

    A total of about 43 computed tomography scanners were operating in the Autonomous Community of Madrid during 1991. A sample of 14 facilities was selected to perform dosimetric measurements in order to obtain characteristic dose profiles. From these, some quantities as the computed tomography dose index and the enhancement factor were calculated and analysed for the most common technique settings. Relations were established between the dosimetric results and technical characteristics of the scanners. (Author)

  19. I-123 iomazenil single photon emission computed tomography for detecting loss of neuronal integrity in patients with traumatic brain injury

    OpenAIRE

    Abiko, Kagari; Ikoma, Katsunori; Shiga, Tohru; Katoh, Chietsugu; Hirata, Kenji; Kuge, Yuji; Kobayashi, Kentaro; Tamaki, Nagara

    2017-01-01

    Background Traumatic brain injury (TBI) causes brain dysfunction in many patients. Using C-11 flumazenil (FMZ) positron emission tomography (PET), we have detected and reported the loss of neuronal integrity, leading to brain dysfunction in TBI patients. Similarly to FMZ PET, I-123 iomazenil (IMZ) single photon emission computed tomography (SPECT) is widely used to determine the distribution of the benzodiazepine receptor (BZR) in the brain cortex. The purpose of this study is to examine whet...

  20. Nuclear Energy Center Site Survey, 1975. Part III. Technical considerations

    International Nuclear Information System (INIS)

    1976-01-01

    Studies of the technical feasibility of nuclear energy centers (NECs) and the comparison between NEC technical feasibility and that of nuclear facilities on dispersed sites are reviewed. The conclusions related to technical feasibility of NEC are summarized. Technical feasibility was found to rest mainly on five major issues: heat dissipation, transmission, facility construction, radiological impact, and environmental impact. Although general conclusions can be reached in these five areas, it is recognized that they are interdependent, and detailed site-by-site analysis will be necessary. Some general conclusions on technical feasibility of NECs are presented, then detailed conclusions derived from the technical evaluation of NECs compared to dispersed site facilities are presented. The findings of this study on each of the five major feasibility issues are then discussed in sequence. The study concludes that nuclear energy centers, as defined herein, are technically feasible

  1. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  2. Characterization of the radon source in North-Central Florida. Final report part 1 -- Final project report; Final report part 2 -- Technical report

    International Nuclear Information System (INIS)

    1997-01-01

    This report contains two separate parts: Characterization of the Radon Source in North-Central Florida (final report part 1 -- final project report); and Characterization of the Radon Source in North-Central Florida (technical report). The objectives were to characterize the radon 222 source in a region having a demonstrated elevated indoor radon potential and having geology, lithology, and climate that are different from those in other regions of the U.S. where radon is being studied. Radon availability and transport in this region were described. Approaches for predicting the radon potential of lands in this region were developed

  3. How to be an Effective Technical Writer?

    Directory of Open Access Journals (Sweden)

    M Solaiman Ali

    2012-07-01

    Full Text Available Abstract--This paper has focused on technical writing as a skill for engineers. It has sought to define technical writing and throw light on the content and technique of writing the various components of successful technical reports (for example, articles, papers, or research reports, such as theses and dissertations. Then, it has highlighted other special features and principles of effective technical writing. The material in this paper is divided into seven major parts. Part 1 (Technical writing for engineers stresses that a successful engineering career requires strong writing skills. Part 2 (How to write the major sections or elements of a report describes the techniques of writing the abstract, introduction, literature review, procedure/methods & materials, results, discussion, conclusion, and recommendations. Part 3 (Special features of technical writing brings into focus some of the special features of technical writing such as tables & graphs in the text, graphics in instructions, team writing, ethics (plagiarism, document sources, three citation styles and IEEE reference style. Part 4 (Technical usage deals with writing abbreviations, initialisms and acronyms, numbers, units of measurement, and equations.Part 5 (Technical style highlights the imperative writing style and other features of technical writing such as the use of active and passive voices, plain vs. complex syntax, avoiding redundant or superfluous expressions, and vague generalities, using words or expressions with visual impact, the past tense to describe experimental work, the present tense to describe hypotheses, principles, theories and truths, and breaking up the text of the report into short sections. Part 6 (Document specifications emphasizes the technical writer’s need to conform to such document specifications as word count, format, font, number of words per line of text imposed. Part 7 (Reader-friendly technical writing suggests choosing the varied writing modes

  4. Technical and instrumentational foundations of PET/MRI

    NARCIS (Netherlands)

    Rausch, Ivo; Quick, Harald H.; Cal-Gonzalez, Jacobo; Sattler, Bernhard; Boellaard, Ronald; Beyer, Thomas

    This paper highlights the origins of combined positron emission tomography (PET) and magnetic resonance imaging (MRI) whole-body systems that were first introduced for applications in humans in 2010. This text first covers basic aspects of each imaging modality before describing the technical and

  5. Technical reliability of geological disposal for high-level radioactive wastes in Japan. The second progress report. Part 3. Safety assessment for geological disposal systems

    International Nuclear Information System (INIS)

    1999-11-01

    Based on the Advisory Committee Report on Nuclear Fuel Cycle Backend Policy submitted to the Japanese Government in 1997, JNC documents the progress of research and development program in the form of the second progress report (the first one published in 1992). It summarizes an evaluation of the technical reliability and safety of the geological disposal concept for high-level radioactive wastes (HLW) in Japan. The present document, the part 3 of the progress report, concerns safety assessment for geological disposal systems definitely introduced in part 1 and 2 of this series and consists of 9 chapters. Chapter I concerns the methodology for safety assessment while Chapter II deals with diversity and uncertainty about the scenario, the adequate model and the required data of the systems above. Chapter III summarizes the components of the geological disposal system. Chapter IV refers to the relationship between radioactive wastes and human life through groundwater, i.e. nuclide migration. In Chapter V is made a reference case which characterizes the geological environmental data using artificial barrier specifications. (Ohno. S.)

  6. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  7. Tele-maintenance 'intelligent' system for technical plants result management

    International Nuclear Information System (INIS)

    Concetti, Massimo; Cuccioletta, Roberto; Fedele, Lorenzo; Mercuri, Giampiero

    2009-01-01

    The management of technical plant for productivity and safety is generally a complex activity, particularly when many plants distributed in the territory are considered (i.e. the more and more frequent case of outsourced plants maintenance by specialized companies), granted quality and cost results are required (i.e. the case of some rather innovative contract solutions) and the technology involved is heterogeneous and innovative (i.e. electro-mechanical plants). In order to efficiently achieve the above aims an 'intelligent' maintenance-management system for the distant monitoring and controlling by a remote control center has been developed. The so-called GrAMS (granted availability management system) system is conceived to give to organizations involved in technical-industrial plants management the possibility to tend to a 'well-known availability' and 'zero-failures' management. In particular, this study deals with the diagnostic aspects and safety level of technical plants (such as elevators, thermo-technical plants, etc.), and with the involvement of ad hoc designed software analysis tools based on neural networks and reliability indicators. Part of the research dealing with the tele-maintenance intelligent system has been financed by the Italian High Institute for Safety (ISPESL) and led to the development of a pre-industrial prototype whose realization and testing is here described

  8. 12 CFR Appendix I to Part 27 - Monthly Home Loan Activity Format

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Monthly Home Loan Activity Format I Appendix I to Part 27 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY FAIR HOUSING HOME LOAN DATA SYSTEM Pt. 27, App. I Appendix I to Part 27—Monthly Home Loan Activity Format EC22SE91...

  9. Military Curricula for Vocational & Technical Education. Club Restaurant Operations, Part I, 9-9.

    Science.gov (United States)

    Army Quartermaster School, Ft. Lee, VA.

    These reading materials, self-test reviews, and examination for part 1 of a secondary-postsecondary subcourse in club management operations are one of a number of military-developed curriculum packages selected for adaptation to vocational instruction and curriculum development in civilian settings. Five lessons focusing on two topics are included…

  10. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice. Copyright © 2010. Published by Elsevier Inc.

  11. Basic technological aspects and optimization problems in X-ray computed tomography (C.T.)

    International Nuclear Information System (INIS)

    Allemand, R.

    1987-01-01

    The current status and future prospects of physical performance are analysed and the optimization problems are approached for X-ray computed tomography. It is concluded that as long as clinical interest in computed tomography continues, technical advances can be expected in the near future to improve the density resolution, the spatial resolution and the X-ray exposure time. (Auth.)

  12. Rapid and efficient radiosynthesis of [{sup 123}I]I-PK11195, a single photon emission computed tomography tracer for peripheral benzodiazepine receptors

    Energy Technology Data Exchange (ETDEWEB)

    Pimlott, Sally L. [Department of Clinical Physics, West of Scotland Radionuclide Dispensary, Western Infirmary, G11 6NT Glasgow (United Kingdom)], E-mail: s.pimlott@clinmed.gla.ac.uk; Stevenson, Louise [Department of Chemistry, WestCHEM, University of Glasgow, G12 8QQ Glasgow (United Kingdom); Wyper, David J. [Institute of Neurological Sciences, Southern General Hospital, G51 4TF Glasgow (United Kingdom); Sutherland, Andrew [Department of Chemistry, WestCHEM, University of Glasgow, G12 8QQ Glasgow (United Kingdom)

    2008-07-15

    Introduction: [{sup 123}I]I-PK11195 is a high-affinity single photon emission computed tomography radiotracer for peripheral benzodiazepine receptors that has previously been used to measure activated microglia and to assess neuroinflammation in the living human brain. This study investigates the radiosynthesis of [{sup 123}I]I-PK11195 in order to develop a rapid and efficient method that obtains [{sup 123}I]I-PK11195 with a high specific activity for in vivo animal and human imaging studies. Methods: The synthesis of [{sup 123}I]I-PK11195 was evaluated using a solid-state interhalogen exchange method and an electrophilic iododestannylation method, where bromine and trimethylstannyl derivatives were used as precursors, respectively. In the electrophilic iododestannylation method, the oxidants peracetic acid and chloramine-T were both investigated. Results: Electrophilic iododestannylation produced [{sup 123}I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than achievable using the halogen exchange method investigated. Using chloramine-T as oxidant provided a rapid and efficient method of choice for the synthesis of [{sup 123}I]I-PK11195. Conclusions: [{sup 123}I]I-PK11195 has been successfully synthesized via a rapid and efficient electrophilic iododestannylation method, producing [{sup 123}I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than previously achieved.

  13. Intra-operative application of optical coherence tomography with an operating microscope.

    Science.gov (United States)

    Just, T; Lankenau, E; Hüttmann, G; Pau, H W

    2009-09-01

    To introduce the use of optical coherence tomography with an operating microscope for intra-operative evaluation of the human larynx. A specially equipped operating microscope with integrated spectral domain optical coherence tomography apparatus was used during microlaryngoscopy. Technical improvements in optical coherence tomography equipment (e.g. pilot beam, variable focal distance, improved image quality and integration into an operating microscope) have enabled greater sensitivity and imaging speed and a non-contact approach. Spectral domain optical coherence tomography now enables a better correlation between optical coherence tomography images and histological findings. With this new technology, the precision of biopsy can be improved during microlaryngoscopy. Use of this new optical coherence tomography technology, integrated into an operating microscope, enables the surgeon to define the biopsy site location and resection plane precisely, while the optical zoom of the operating microscope can be used over the complete range.

  14. Portable Intraoperative Computed Tomography Scan in Image-Guided Surgery for Brain High-grade Gliomas: Analysis of Technical Feasibility and Impact on Extent of Tumor Resection.

    Science.gov (United States)

    Barbagallo, Giuseppe M V; Palmucci, Stefano; Visocchi, Massimiliano; Paratore, Sabrina; Attinà, Giancarlo; Sortino, Giuseppe; Albanese, Vincenzo; Certo, Francesco

    2016-03-01

    Intraoperative magnetic resonance imaging is the gold standard among image-guided techniques for glioma surgery. Scant data are available on the role of intraoperative computed tomography (i-CT) in high-grade glioma (HGG) surgery. To verify the technical feasibility and usefulness of portable i-CT in image-guided surgical resection of HGGs. This is a retrospective series control analysis of prospectively collected data. Twenty-five patients (Group A) with HGGs underwent surgery using i-CT and 5-aminolevulinic acid (5-ALA) fluorescence. A second cohort of 25 patients (Group B) underwent 5-ALA fluorescence-guided surgery but without i-CT. We used a portable 8-slice CT scanner and, in both groups, neuronavigation. Extent of tumor resection (ETOR) and pre- and postoperative Karnofsky performance status (KPS) scores were measured; the impact of i-CT on overall survival (OS) and progression-free survival (PFS) was also analyzed. In 8 patients (32%) in Group A, i-CT revealed residual tumor, and in 4 of them it helped to also resect pathological tissue detached from the main tumor. EOTR in these 8 patients was 97.3% (96%-98.6%). In Group B, residual tumor was found in 6 patients, whose tumor's mean resection was 98% (93.5-99.7). The Student t test did not show statistically significant differences in EOTR in the 2 groups. The KPS score decreased from 67 to 69 after surgery in Group A and from 74 to 77 in Group B (P = .07 according to the Student t test). Groups A and B did not show statistically significant differences in OS and PFS (P = .61 and .46, respectively, by the log-rank test). No statistically significant differences in EOTR, KPS, PFS, and OS were observed in the 2 groups. However, i-CT helped to verify EOTR and to update the neuronavigator with real-time images, as well as to identify and resect pathological tissue in multifocal tumors. i-CT is a feasible and effective alternative to intraoperative magnetic resonance imaging. Portable i-CT can provide useful

  15. [Cardiac computed tomography: new applications of an evolving technique].

    Science.gov (United States)

    Martín, María; Corros, Cecilia; Calvo, Juan; Mesa, Alicia; García-Campos, Ana; Rodríguez, María Luisa; Barreiro, Manuel; Rozado, José; Colunga, Santiago; de la Hera, Jesús M; Morís, César; Luyando, Luis H

    2015-01-01

    During the last years we have witnessed an increasing development of imaging techniques applied in Cardiology. Among them, cardiac computed tomography is an emerging and evolving technique. With the current possibility of very low radiation studies, the applications have expanded and go further coronariography In the present article we review the technical developments of cardiac computed tomography and its new applications. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  16. Technical and Non-Technical Issues towards the Commercialisation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Chozas, Julia Fernandez

    , it then determines the stages where there is a gap in research, and lastly, it analyses the identified key subjects. Accordingly, the thesis elaborates on seven areas: . i. It examines regulatory frameworks for wave energy developments and how they affect project execution. . ii. It investigates the role...... are of relevance to successfully reach the commercialisation of WECs and need attention from the sector as such, not least from device developers. The thesis is presented in two parts: a main introduction and a collection of papers. The first part provides a brief history of wave energy, introduces the research...... topic, describes the different disciplines addressed in the thesis and relates them. The eight papers comprise the core part of the work. The papers address the research topic in different ways: from a legal, social, technical and economic viewpoint, and from various WEC development stages. All...

  17. Cellular imaging electron tomography and related techniques

    CERN Document Server

    2018-01-01

    This book highlights important techniques for cellular imaging and covers the basics and applications of electron tomography and related techniques. In addition, it considers practical aspects and broadens the technological focus by incorporating techniques that are only now becoming accessible (e.g. block face imaging).  The first part of the book describes the electron microscopy 3D technique available to scientists around the world, allowing them to characterize organelles, cells and tissues. The major emphasis is on new technologies like scanning transmission electron microscopy (STEM) tomography, though the book also reviews some of the more proven technologies like electron tomography. In turn, the second part is dedicated to the reconstruction of data sets, signal improvement and interpretation.

  18. Japanese contributions to IAEA INTOR workshop, phase two A, part 2 chapter VII: technical benefit

    International Nuclear Information System (INIS)

    Itoh, Shin-ichi; Iida, Hiromasa; Tomabechi, Ken; Tone, Tatsuzo; Fujisawa, Noboru.

    1985-07-01

    This report corresponds to Chapter VII of Japanese contribution report to IAEA INTOR Workshop, Phase Two A, Part 2. The purpose of technical benefit study is to examine the implications of having different manufacturers fabricate components of a major system of INTOR. A systematic examinations of advantages and disadvantages of designing and fabricating major INTOR components in the frame of one international joint projects is performed. (author)

  19. Advanced technologies and new roles for VTOL aircraft (Part 2/2)

    Energy Technology Data Exchange (ETDEWEB)

    Renaud, J.P. [Office National d' Etudes et de Recherches Aerospatiales (ONERA-University), 13 - Marseilles (France)

    2000-06-01

    This survey paper intends to overview some main technical evolutions impacting present and future general design of rotor-craft (for vehicles, engines and systems), including helicopter and future tilt-rotor. These trends tend to achieve a better adaptation to a wide range of mission requirements with an economic aircraft optimisation and an enhanced safety level and environmental impact. Whilst part I considered the whole rotor-craft technical activity the present part II is essentially focused on market issues and the tilt-rotor concept introduction. (author)

  20. No Fault Found events in maintenance engineering Part 2: Root causes, technical developments and future research

    International Nuclear Information System (INIS)

    Khan, Samir; Phillips, Paul; Hockley, Chris; Jennions, Ian

    2014-01-01

    This is the second half of a two paper series covering aspects of the no fault found (NFF) phenomenon, which is highly challenging and is becoming even more important due to increasing complexity and criticality of technical systems. Part 1 introduced the fundamental concept of unknown failures from an organizational, behavioral and cultural stand point. It also reported an industrial outlook to the problem, recent procedural standards, whilst discussing the financial implications and safety concerns. In this issue, the authors examine the technical aspects, reviewing the common causes of NFF failures in electronic, software and mechanical systems. This is followed by a survey on technological techniques actively being used to reduce the consequence of such instances. After discussing improvements in testability, the article identifies gaps in literature and points out the core areas that should be focused in the future. Special attention is paid to the recent trends on knowledge sharing and troubleshooting tools; with potential research on technical diagnosis being enumerated

  1. Nordic study on reactor waste. Technical part 3

    International Nuclear Information System (INIS)

    1981-08-01

    The ground disposal alternatives examined in the Nordic study are based on establishment of relevant product specifications which can be adapted to the safety analysis of the entire waste handling sequence. Such product specifications would in turn influence the choice of incorporation techniques and may enable an optimization of the process. In order to interprete the small-scale laboratory tests with respect to long-term performance of full-scale products there were accomplished: - qualitative evaluations of the relevance of product properties for normal and abnormal events during storage, transport and disposal; - attempts to quantify the relevance of different properties, i.e. their influence on radiation doses from different stages of well specified waste management system; - assessments of available laboratory tests and of correlations between results from such tests and the long-term performance of full-scale technical products; - studies of reaction mechanisms and parameters that can affect the long-term performance of disposed products; - laboratory incorporation experiments to study impacts of process variables on the fixation of ion exchange wastes in cement and bitumen; - full-scale tests to study product performance under simulated accident conditions. (EG)

  2. 123I-5-I-R91150, a new single-photon emission tomography ligand for 5-HT2A receptors: influence of age and gender in healthy subjects

    International Nuclear Information System (INIS)

    Baeken, C.; D'haenen, H.; Flamen, P.; Bossuyt, A.; Mertens, J.; Terriere, D.; Chavatte, K.; Boumon, R.

    1998-01-01

    5-HT 2A receptors have been implicated in the pathophysiology of mood disorders and in the therapeutic effect of the so-called atypical antipsychotics. Recently, a new radioiodinated ligand with high affinity and selectivity for serotonin 5-HT 2A receptors, 123 iodinated 4-amino-N-1-[3-(4-fluorophenoxy)propyl-4-methyl-4-piperidinyl] 5-iodo-2-methoxybenzamide ( 123 I-5-I-R91150), has been developed and has been shown to be suitable for single-photon emission tomography (SPET) imaging. In this study the influence of age and gender on the ligand binding was investigated in normal volunteers. One hundred and fifty MBq of 123 I-5-I-R91150 was administered to 26 normal volunteers (13 females and 13 males) with an age range of 23-60 years. SPET imaging was performed with a triple-headed gamma camera. For semi-quantitative analysis, ratios of ligand binding in different regions of interest to the binding in the cerebellum were calculated. Mean ratios of 1.7 were obtained. No gender difference was demonstrated. 5-HT 2A binding was shown to decline with age. Over an age range of 40 years a reduction in ligand binding of 42%±7% was found. These results are in agreement with in vitro and positron emission tomography findings of a decline in 5-HT 2A receptor binding with age. The findings confirm the suitability of 123 I-5-I-R91150 for SPET imaging of 5-HT 2A receptors, and highlight the necessity for age-matched controls in clinical studies. (orig.)

  3. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  4. Complex investigation of thermo-technical parameters of Ruskov andesite

    Directory of Open Access Journals (Sweden)

    František Krepelka

    2006-12-01

    Full Text Available The research of thermo-technical parameters of Ruskov andesite was made as a part of the complex research of its properties as well as of rock disintegration by the action of chemical flame on the rock surface, i.e. thermal spalling in particular. Thermal spalling is a process in which thermal stresses are induced in the surface layer of rock whose surface is thereby disintegrated into small parts, the so called spalls, by the brittle manner. The evaluation of thermo-technical properties of the studied rocks is necessary for the qualification and quantification of the thermal spalling process. The measured and evaluated parameters were the coefficient of linear thermal expansion, the coefficient of thermal conductivity, the specific heat capacity and the coefficient of thermal diffusivity. Andesite from the Ruskov locality was chosen as a basic experimental material for the investigation of thermal spalling upon preliminary experiments. The estimated thermo-technical parameters were analyzed regarding the application of thermal spalling for the disintegration of the Ruskov andesite. The outcome as that the values of determine thermo-technical parameters established an expectation for its successful application.

  5. Tumour screening by means of tomography methods

    International Nuclear Information System (INIS)

    Diederich, S.

    2005-01-01

    Tomography methods such as computer tomography (CT), magnetic resonance tomography (MRT), and sonography/ultrasound examinations make it possible to detect small asymptomatic tumours, thus potentially preventing their manifestation at an advanced stage and improving survival prospects for the patients concerned. There are data available on various common tumours which show that modern tomography methods are capable of detecting not only small asymptomatic tumours but also their benign precursors (e.g. polyps of the large intestine). This has been demonstrated for lung cancer, colon cancer and breast cancer. However, it has not been possible to date to show for any tomography method or any type of tumour that the systematic use of such diagnostic procedures does anything to lower the mortality rate for that tumour. For other types of tumour (pancreatic cancer, kidney cancer, ovary cancer) the above named methods are either not sufficiently sensitive or the body of data that has accumulated on their respective use is too small to judge the benefit of tomography screenings. Current technical developments make it appear probable that for many types of cancer the reliability with which small tumours can be detected will improve in future. Studies aimed at clarifying the potential of screenings for reducing mortality rates are already underway for lung cancer and would be worthwhile performing for other tumour types

  6. Moving the Needle: The Effect of Faculty Development on Part-Time Teachers at a Technical College

    Science.gov (United States)

    Proeber, Helen R.

    2012-01-01

    In the business division of the technical college in which this study occurred, there was a need to change the way part-time faculty prepared course syllabi. The implementation of a professional development workshop that focused on the components and necessity of the syllabus provided the teachers new information they needed to be prepared for the…

  7. Present results and perspectives of positron emission tomography in oncology and radiotherapy

    International Nuclear Information System (INIS)

    Lonneux, M.; Sibomana, M.; Pauwels, S.; Gregoire, V.

    1999-01-01

    Positron emission tomography (PET) is one of the most promising diagnostic procedures in oncology. Using the glucose analogue fluorodeoxyglucose, PET produces whole-body images and is highly sensitive for tumor diagnosis and staging. We review three particular clinical situations in which PET-FDG has proven not only its diagnostic accuracy, but also its impact on patient management, i.e., the staging of non-small cell lung cancer, diagnosis and staging of colo-rectal cancer and head and neck cancer recurrence. Image registration yields anatomic-metabolic images that could be used as additional information for the determination of radiation fields. Tracer and technical issues remain to be solved before PET can be routinely used for that purpose. (authors)

  8. Computed tomography of the gastro-intestinal tract : its value

    Energy Technology Data Exchange (ETDEWEB)

    Reeders, J W.A.J. [Academic Medical Center, Amsterdam (Netherlands)

    1996-12-31

    The subject discussed include indications and accuracy of CT - computed tomography, technical considerations, common pitfalls in CT interpretation, parameters for CT evaluation, benign lesions, double halo and target signs, hyperattenuated, inflammatory bowel disease, intestinal ischaemia, primary adenocarcinoma of the GIT, lymphoma and leiomyosarcoma (3 refs.).

  9. Computed tomography of the gastro-intestinal tract : its value

    International Nuclear Information System (INIS)

    Reeders, J.W.A.J.

    1995-01-01

    The subject discussed include indications and accuracy of CT - computed tomography, technical considerations, common pitfalls in CT interpretation, parameters for CT evaluation, benign lesions, double halo and target signs, hyperattenuated, inflammatory bowel disease, intestinal ischaemia, primary adenocarcinoma of the GIT, lymphoma and leiomyosarcoma (3 refs.)

  10. CO2 capture from power plants. Part I : A parametric study of the technical performance based on monoethanolamine

    NARCIS (Netherlands)

    Abu-Zahra, M. R. M.; Schneiders, L. H. J.; Niederer, J. P. M.; Feron, P. H. M.; Versteeg, G. F.

    Capture and storage of CO2 from fossil fuel fired power plants is drawing increasing interest as a potential method for the control of greenhouse gas emissions. An optimization and technical parameter study for a CO2 capture process from flue gas of a 600 MWe bituminous coal fired power plant, based

  11. CO2 capture from power plants: Part I. A parametric study of the technical performance based on monoethanolamine

    NARCIS (Netherlands)

    Abu-Zahra, Mohammad R.M.; Schneiders, Léon H.J.; Niederer, John; Feron, Paul H.M.; Versteeg, Geert

    2007-01-01

    Capture and storage of CO2 from fossil fuel fired power plants is drawing increasing interest as a potential method for the control of greenhouse gas emissions. An optimization and technical parameter study for a CO2 capture process from flue gas of a 600 MWe bituminous coal fired power plant, based

  12. Computerized tomography in orthopaedics and traumatology

    International Nuclear Information System (INIS)

    Boettger, E.; Heckl, R.; Rehabilitations-Krankenhaus Langensteinbach, Karlsbad

    1981-01-01

    Computerized tomography in traumatology is the selected method for the indications mentioned, so that angiographic investigations are only necessary in exceptional cases. Computerized tomography is also better than other methods when diagnozing soft part tumours, however, angiography is still indicated preoperatively for individual cases. CT is only good as additional help to conventional diagnostics with bone tumours. The differential diagnosis cysts-tumour is possible using contrast medium injections. The frequently large soft part share of tumours is recognizable with osteolytic tumours so that a better irradiation and operation planning can be effected. Diseases in the spinal canal can only be assessed with reservation using modern equipment. Lumbar dislocations of the disk can mostly not be sufficiently determined. Perivertebral abscesses can be certainly detected using computerized tomography. This is particularly so for abscesses prior to calcification. (orig.) [de

  13. Tehnička služba Vojske Jugoslavije i pravci njenog razvoja / Technical Service of the Army of Yugoslavia and the directions of its development

    Directory of Open Access Journals (Sweden)

    Milun Kokanović

    2002-07-01

    Full Text Available Tehničko-tehnološki razvoj u naučno i ekonomski moćnim zemljama sveta poslednjih decenija najvećim delom je potenciran i iskorišćen za proizvodnju oružja i sredstava naoružanja i vojne opreme. Time je radikalno izmenjena osnova rata, tako da se sa nuklearne, strategijske koncepcije prelazi na informatičku koncepciju rata. Tehnička služba Vojske Jugoslavije (Tehnička služba KoV, Vazduhoplovno-tehnička služba i Mornaričko-tehnička služba shodno izmenjenim uslovima, pratila je i izučavala razvoj tehničko-tehnološkog faktora u svetu i njegov uticaj na oružanu borbu. Kadrovskim osposobljavanjem, racionalnom organizacijom sistema tehničkog obezbeđenja i materijalnom podrškom, uspešno je podržavala potrebe Vojske Jugoslavije u razvoju tehničkih sredstava naoružanja i vojne opreme njihovom snabdevanju i održavanju u čitavom životnom veku. / Technological and technological development in the scientifically and economically powerful countries of the world in the last decades has been mostly emphasized and used for the production of weapons and weapons and military equipment. This radically changed the basis of the war, so that from the nuclear, strategic conception it switched to the informational conception of war. The Technical Service of the Army of Yugoslavia (Technical Service of Land Army, Aircraft and Technical Service and Naval-Technical Service, in accordance with the changed conditions, monitored and developed the technical and technological factors in the world and its impact on the armed struggle. Through staff training, rational organization of the system of technical security and material support, it successfully supported the needs of the Army of Yugoslavia in the development of technical means of arms and military equipment to their supply and maintenance throughout the life-span.

  14. Microsurgical Bypass Training Rat Model, Part 1: Technical Nuances of Exposure of the Aorta and Iliac Arteries.

    Science.gov (United States)

    Tayebi Meybodi, Ali; Lawton, Michael T; Mokhtari, Pooneh; Yousef, Sonia; Gandhi, Sirin; Benet, Arnau

    2017-11-01

    Animal models using rodents are frequently used for practicing microvascular anastomosis-an essential technique in cerebrovascular surgery. However, safely and efficiently exposing rat's target vessels is technically difficult. Such difficulty may lead to excessive hemorrhage and shorten animal survival. This limits the ability to perform multiple anastomoses on a single animal and may increase the overall training time and costs. We report our model for microsurgical bypass training in rodents in 2 consecutive articles. In part 1, we describe the technical nuances for a safe and efficient exposure of the rat abdominal aorta and common iliac arteries (CIAs) for bypass. Over a 2-year period, 50 Sprague-Dawley rats underwent inhalant anesthesia for practicing microvascular anastomosis on the abdominal aorta and CIAs. Lessons learned regarding the technical nuances of vessel exposure were recorded. Several technical nuances were important for avoiding intraoperative bleeding and preventing animal demise while preparing an adequate length of vessels for bypass. The most relevant technical nuances include (1) generous subcutaneous dissection; (2) use of cotton swabs for the blunt dissection of the retroperitoneal fat; (3) combination of sharp and blunt dissection to isolate the aorta and iliac arteries from the accompanying veins; (4) proper control of the posterior branches of the aorta; and (5) efficient division and mobilization of the left renal pedicle. Applying the aforementioned technical nuances enables safe and efficient preparation of the rat abdominal aorta and CIAs for microvascular anastomosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Nordic study on reactor waste. Technical part 1 and 2

    International Nuclear Information System (INIS)

    1981-08-01

    An important part of the Nordic studies on system- and safety analysis of the management of low and medium level radioactive waste from nuclear power plants, is the safety analysis of a Reference System. This reference system was established within the study and is described in this Technical Part 1. The reference system covers waste management Schemes that are potential possibilities in either one of the four participating Nordic countries. The reference system is based on: a power reactor system consisting of 6 BWR's of 500 MWe each, operated simultaneously over the same 30 year period, and deep bed granular ion exchange resin wastes from the Reactor Water Clean-Up System (RWCS and powdered ion exchange resin from the Spent Fuel Pool Cleanup System (SFPCS)). Both waste types are supposed to be solidified by mixing with cement and bitumen. Two basic types of containers are considered. Standard 200 liter steel drums and specially made cubicreinforced concrete moulds with a net volume of 1 m 3 . The Nordic study assumes temporary storage of the solidified waste for a maximum of 50 years before the waste is transferred to the disposal site. Transportation of the waste from the storage facilitiy to the disposal site will be by road or sea. Three different disposal facilities are considered: Shallow land burial, near surface concrete bunker, and rock cavern with about 30 m granite cover. (EG)

  16. The Role of Formal and Informal Forces in Shaping Consumption and Implications for a Sustainable Society. Part I

    Directory of Open Access Journals (Sweden)

    Oksana Mont

    2010-07-01

    Full Text Available Addressing climate change and the collapse of ecosystems without threatening the economy, while simultaneously improving the well-being of all people and ensuring social justice and equality, seems to be the largest challenge in the history of mankind. So far, all the efforts to address growing environmental and human problems through technological solutions and policy measures have been largely outpaced by growing population and increasing consumption levels. Therefore, an understanding of the essential driving forces and complexities of consumption, and of how environmental impacts from rising consumption can be reduced, is becoming increasingly important. This understanding can be achieved by analyzing not only economic frameworks, political settings, business models, and technological innovations, but also social norms, psychological factors, and collective and individual decision-making processes. This article, Part I, provides a meta-analysis of the main political, economic, technological, and business drivers of contemporary consumption and offers a systematic discussion of the relevance of these factors for the instigation of change towards sustainable patterns and levels of consumption. The main conclusion from Part I and II is that a systems-thinking approach is required in order to understand how various political, technical, social, economic, and psychological drivers overlap and influence each other in creating our consumer society.

  17. Students seeking technical internships as part of an exchange program

    OpenAIRE

    Nystrom, Lynn A.

    2004-01-01

    Virginia Tech students are seeking the support of research centers, academic departments, and area businesses to provide opportunities for technical internships through the International Association for the Exchange of Students for Technical Experience (IAESTE).

  18. Monotonicity-based electrical impedance tomography for lung imaging

    Science.gov (United States)

    Zhou, Liangdong; Harrach, Bastian; Seo, Jin Keun

    2018-04-01

    This paper presents a monotonicity-based spatiotemporal conductivity imaging method for continuous regional lung monitoring using electrical impedance tomography (EIT). The EIT data (i.e. the boundary current-voltage data) can be decomposed into pulmonary, cardiac and other parts using their different periodic natures. The time-differential current-voltage operator corresponding to the lung ventilation can be viewed as either semi-positive or semi-negative definite owing to monotonic conductivity changes within the lung regions. We used these monotonicity constraints to improve the quality of lung EIT imaging. We tested the proposed methods in numerical simulations, phantom experiments and human experiments.

  19. The industrial computerized tomography applied to the rock analysis

    International Nuclear Information System (INIS)

    Tetzner, Guaraciaba de Campos

    2008-01-01

    This work is a study of the possibilities of the technical applications of Computerized Tomography (CT) by using a device developed in the Radiation Technology Center (CTR), Institute for Energy and Nuclear Research (IPEN-CNEN/SP). The equipment consists of a gamma radiation source ( 60 Co), a scintillation detector of sodium iodide doped with thallium (NaI (Tl)), a mechanical system to move the object (rotation and translation) and a computer system. This operating system has been designed and developed by the CTR-IPEN-CNEN/SP team using national resources and technology. The first validation test of the equipment was carried out using a cylindrical sample of polypropylene (phantom) with two cylindrical cavities (holes) of 5 x 25 cm (diameter and length). In these tests, the holes were filled with materials of different density (air, oil and metal), whose attenuation coefficients are well known. The goal of this first test was to assess the response quality of the equipment. The present report is a study comparing computerized tomography equipment CTR-IPEN-CNEN/SP which uses a source of gamma radiation ( 60 Co) and other equipment provided by the Department of Geosciences in the University of Texas (CTUT), which uses an X-ray source (450 kV and 3.2 mA). As a result, the images obtained and the comprehensive study of the usefulness of the equipment developed here strengthened the proposition that the development of industrial computerized tomography is an important step toward consolidating the national technology. (author)

  20. Technical co-operation report for 1999. Report by the Director General

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-08-01

    This report presents the IAEA Technical Co-operation (TC) activities in 1999 and covers three separate topics. Part I reports on the Strengthening of TC and looks at the elements of the TC Strategy and how they contributed to the TC Programme. Part II reports on the major achievements of the TC Programme in 1999 in different regions of the world. In addition to reviewing some of the results of national and regional activities in each region - including activities under Regional Co-operation Agreements - this section looks at three interregional projects, and provides highlights of selected projects that were closed in 1999. Part III presents a technical discussion of the financial parameters of the TC Programme. A more detailed review of resources and contributions, disbursements, and non-financial indicators is provided in a Supplement to this report.

  1. Technical co-operation report for 1999. Report by the Director General

    International Nuclear Information System (INIS)

    2000-08-01

    This report presents the IAEA Technical Co-operation (TC) activities in 1999 and covers three separate topics. Part I reports on the Strengthening of TC and looks at the elements of the TC Strategy and how they contributed to the TC Programme. Part II reports on the major achievements of the TC Programme in 1999 in different regions of the world. In addition to reviewing some of the results of national and regional activities in each region - including activities under Regional Co-operation Agreements - this section looks at three interregional projects, and provides highlights of selected projects that were closed in 1999. Part III presents a technical discussion of the financial parameters of the TC Programme. A more detailed review of resources and contributions, disbursements, and non-financial indicators is provided in a Supplement to this report

  2. Imaging in hematology. Part 2: Computed tomography, magnetic resonance imaging and nuclear imaging

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    A dramatic increase of the role of imaging in diagnosis of blood diseases occurred with the development of computed tomography (CT) and magnetic resonance imaging (MRI). At present CT of the chest, abdomen, and pelvis is routinely employed in diagnostic and staging evaluation. The bone marrow may be imaged by one of several methods, including scintigraphy, CT and MRI. Nuclear imaging at diagnosis can clarify findings of uncertain significance on conventional staging and may be very useful in the setting of large masses to follow responses to therapy nad to evaluate the residual tumor in a large mass that has responded to treatment. Recent developments such as helical CT, single proton emission computed tomography (SPECT) and positron-emission tomography (PET) have continued to advance diagnosis and therapy

  3. INDOT Technical Training Plan : Appendix I

    Science.gov (United States)

    2012-04-01

    The study provides the background documents necessary for the development of a Technical Training Plan and makes recommendations for the content and structure of such a plan for the District Operations, Operations, Capital Program Management, and Eng...

  4. Clinical applications of single photon emission tomography in neuromedicine. Part 1. Neuro-oncology, epilepsy, movement disorders, cerebrovascular disease

    International Nuclear Information System (INIS)

    Bartenstein, P.; Gruenwald, F.; Kuwert, T.; Tatsch, K.; Sabri, O.; Benkert, O.; Fahlbusch, R.; Gruender, G.; Herzholz, K.; Weiller, C.

    2000-01-01

    Single photon emission tomography is, because of its availability and the relatively low costs, the functional imaging modality currently most widely used for clinical applications in the brain. Beside the application of radiopharmaceuticals for the assessment of regional cerebral blood flow there is an increasing clinical use of more selective SPECT-radiopharmaceuticals, like amino acid analogs or receptor ligands. This article gives in its first part a critical review of the clinical applications of SPECT in neuro-oncology, epilepsy, basal ganglia disorders and cerebrovascular disease. (orig.) [de

  5. How to be an Effective Technical Writer?

    OpenAIRE

    M Solaiman Ali; Dheya Al-Othmany

    2012-01-01

    Abstract--This paper has focused on technical writing as a skill for engineers. It has sought to define technical writing and throw light on the content and technique of writing the various components of successful technical reports (for example, articles, papers, or research reports, such as theses and dissertations). Then, it has highlighted other special features and principles of effective technical writing. The material in this paper is divided into seven major parts. Part 1 (Technical w...

  6. Safety analysis of RA Reactor operation I-III; Analiza sigurnosti rada Reaktora RA I - III, IZ-213-0322-1963

    Energy Technology Data Exchange (ETDEWEB)

    Raisic, N [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1963-02-15

    This safety analysis report covers the following three parts: Technical and operational characteristics of the RA reactor; Accidents analysis; and Environmental effects of the maximum possible accident. [Serbo-Croat] Ovaj izvestaj o analizi sigurnosti rada reaktora RA sastoji se od tri dela: Tehnicke i pogonske karakteristike reaktora RA; Analiza akcidenta; i Posledice maksimalno moguceg akcidenta na okolinu reaktora.

  7. Long-term solar activity and terrestrial connections. Part I: theory

    Directory of Open Access Journals (Sweden)

    N. D. Diamantides

    Full Text Available The research task described herein aims at the structuring of an analytical tool that traces the time course of geophysical phenomena, regional or global, and compares it to the course of long-term solar conditions, long-term meaning decades or a few centuries. The model is based on the premise that since in a last analysis the preponderance of atmospheric, hydrospheric, and, possibly, some aspects of geospheric phenomena are, or have been, powered by energy issuing from the sun – either now or in the past, the long-term behavior of such phenomena is ultimately "connected" to long-term changes occurring in the sun itself. Accordingly, the proposed research firstly derives and models a stable <i>surrogate patterni> for the long-term solar activity, secondly introduces a <i>transfer-function> algorithm for modeling the connection between the surrogate and terrestrial phenomena viewed as partners in the connection, and thirdly probes the connection outcome for <i>episodic> or <i>unanticipated effectsi> that may arise due to the fact that in the present context, the connection, should it exist, is very likely nonlinear. Part I of the study presents the theory of the concept, while Part II demonstrates the concept's pertinence to a number of terrestrial phenomena.

    Key words. Solar activity · Kolmogorov algorithm

  8. Managing the professional nurse. Part I. The organizational theories.

    Science.gov (United States)

    McClure, M L

    1984-02-01

    How do employment organizations outside the hospital field deal with issues such as staff productivity, motivation, burnout, and high turnover? In Part I of this two-part article, the author presents an overview of modern management theory and practice, drawn from the literature on organizational behavior. She shows how nursing administrators can use this scholarly foundation to better understand the organizing principles and problems of their departments. In Part II (to be published in March 1984), the author applies these classic and relevant theories to the specific challenges that face the manager of professional nurses.

  9. Sobre la partícula «rai» i els tòpics

    Directory of Open Access Journals (Sweden)

    Jaume Solà i Pujols

    2015-11-01

    Full Text Available In the first part of the paper, I characterize the particle "rai", used in some dialects of Catalan, as a topic­emphasizer (by topic I mean left-dislocated constituent. In the second part I use this particle as a criterion to identify the class of topics, and I speculate on the nature of this class, which is in complementary distribution with the class of operators.

  10. Multiple X-ray tomography using transmitted, scattered and fluorescent radiation

    International Nuclear Information System (INIS)

    Cesareo, R.; Brunetti, A.; Golosio, B.; Lopes, R.T.; Barroso, R.C.; Donativi, M.; Castellano, A.; Quarta, S.

    2003-01-01

    A multiple CT-scanner is described, which contemporaneously uses transmitted, scattered and fluorescent X-rays for Imaging. The scanner is characterized by a small size X-ray tube and by four detectors: a ''pencil'' X-ray NaI(Tl) for transmitted tomography, a larger size NaI(Tl) for 90 C o Compton tomography, a thermoelectrically cooled Si-PIN or CdZnTe for fluorescent imaging and a CdZnTe for Rayleigh (or diffraction) tomography. Examples of applications are shown

  11. 48 CFR 15.204-2 - Part I-The Schedule.

    Science.gov (United States)

    2010-10-01

    ... the solicitation: (i) Name, address, and location of issuing activity, including room and building.... Include a brief description of the supplies or services; e.g., item number, national stock number/part...

  12. Recreational technical diving part 1: an introduction to technical diving methods and activities.

    Science.gov (United States)

    Mitchell, Simon J; Doolette, David J

    2013-06-01

    Technical divers use gases other than air and advanced equipment configurations to conduct dives that are deeper and/or longer than typical recreational air dives. The use of oxygen-nitrogen (nitrox) mixes with oxygen fractions higher than air results in longer no-decompression limits for shallow diving, and faster decompression from deeper dives. For depths beyond the air-diving range, technical divers mix helium, a light non-narcotic gas, with nitrogen and oxygen to produce 'trimix'. These blends are tailored to the depth of intended use with a fraction of oxygen calculated to produce an inspired oxygen partial pressure unlikely to cause cerebral oxygen toxicity and a nitrogen fraction calculated to produce a tolerable degree of nitrogen narcosis. A typical deep technical dive will involve the use of trimix at the target depth with changes to gases containing more oxygen and less inert gas during the decompression. Open-circuit scuba may be used to carry and utilise such gases, but this is very wasteful of expensive helium. There is increasing use of closed-circuit 'rebreather' devices. These recycle expired gas and potentially limit gas consumption to a small amount of inert gas to maintain the volume of the breathing circuit during descent and the amount of oxygen metabolised by the diver. This paper reviews the basic approach to planning and execution of dives using these methods to better inform physicians of the physical demands and risks.

  13. Optimisation of post mortem cardiac computed tomography compared to optical coherence tomography and histopathology - Technical note

    DEFF Research Database (Denmark)

    Falk, Erling

    2014-01-01

    . Here, a new method for optimising cardiac coronary CT with optical coherence tomography (OCT) and histopathology is presented. Materials and methods: Twenty human hearts obtained from autopsies were used. A contrast agent that solidifies after cooling was injected into the coronary arteries. CT...... of the images was also developed. Results: We have succeeded in developing a new method for post-mortem coronary CT angiography in which an autopsy heart is placed in a chest phantom to simulate clinical CT. Conclusion: The new method permits comparison of CT with OCT and histopathology. This method can also...

  14. Ultrasonic and computed tomography in radiotherapy planning - a comparison

    International Nuclear Information System (INIS)

    Schertel, L.

    1980-01-01

    The precondition of any radiotherapy is radiation planning. This must be done individually for every patient and must be applicable for any region of the body. Modern irradiation planning requires pictures of the body parts concerned; these can be made by means of the ultrasonic method and computed tomography. This comparative investigation leads to the result (see fig. 4 and 5) that computed tomographic body part pictures should be preferred to those made sonographically. The opinion of Huenig and Co. [8] that ultrasonic tomography will soon lose some of its importance within irradiation planning once computed tomography is introduced could be confirmed by the latest developments. The authors can confirm this also out of their own experience and agree with Winkel and Hermann [23] that computed tomography cannot be done without any more irradiation planning. (orig.) [de

  15. Technical meeting on progress in managing, and limiting the consequences of events exceeding the design basis

    International Nuclear Information System (INIS)

    Fabian, H.

    2004-01-01

    The Technical Groups on 'Reactor Safety' and 'Thermodynamics and Fluid Dynamics' of the Kerntechnische Gesellschaft e.V. organized a joint technical meeting on 'Progress in Managing, and Limiting the Consequences of, Events Exceeding the Design Basis' at the FTU Training Center of the Karlsruhe Research Center. The topic chosen, the papers presented, the presenters, and the non-technical part of the program met with lively interest on the part of institutions in the nuclear field. These were the objectives of the technical meeting: - Establishing a forum for communicating relevant topics. - In-depth discussion of the main topic, i.e. the advanced development of reactor safety, research in the field, and its application, in twenty selected papers presented by speakers from different institutions. - Presentation of topical work in a nuclear technology institution, the Karlsruhe Research Center. (orig.) [de

  16. Target localization on standard axial images in computed tomography (CT) stereotaxis for functional neurosurgery - a technical note

    International Nuclear Information System (INIS)

    Patil, A.-A.

    1986-01-01

    A simple technique for marking functional neurosurgery target on computed tomography (CT) axial image is described. This permits the use of standard axial image for computed tomography (CT) stereotaxis in functional neurosurgery. (Author)

  17. Mixed waste focus area integrated technical baseline report. Phase I, Volume 2: Revision 0

    International Nuclear Information System (INIS)

    1996-01-01

    This document (Volume 2) contains the Appendices A through J for the Mixed Waste Focus Area Integrated Technical Baseline Report Phase I for the Idaho National Engineering Laboratory. Included are: Waste Type Managers' Resumes, detailed information on wastewater, combustible organics, debris, unique waste, and inorganic homogeneous solids and soils, and waste data information. A detailed list of technology deficiencies and site needs identification is also provided

  18. Significance of cranial computer tomography for the early diagnosis of peri- and postnatal damage

    Energy Technology Data Exchange (ETDEWEB)

    Richter, E I

    1981-01-01

    It is reported on examination-technical possibilities with craniocerebral Computer Tomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.

  19. Quality control of aluminium casting: X ray radiography or tomography?

    International Nuclear Information System (INIS)

    Munier, B.; Tamziti, J.; Grignard, A.; Peix, G.; Kaftandjian, V.

    2007-01-01

    Full text of publication follows: X ray radiography has been for years a well known method commonly used for controlling parts either on line or off line. The purpose is to detect internal defects or to achieve reverse engineering on the parts. More recently two-dimensional or three-dimensional Computed Tomography has been introduced and provides key advantages over standard X ray radiography, such as dimensional measurement of complex objects with hidden structures and 3D defect localisation. However, from the user point of view, despite the clear advantages of tomography, the time consuming drawback is predominant, and thus, it is worth assessing the added value of tomography with respect to several radioscopic images. It is clear that there is no unique response to that question. If unacceptable defects are already detected in one radioscopic image, then the sample can be rejected and 3D tomography is useless. On another hand, 3D tomography cannot be replaced if internal structures such as holes must be measured with accuracy. The paper will present a comparison between radiography and tomography for controlling parts in the aluminium casting industry. Advantages and drawbacks of both methods will be reviewed. Performance features in both cases will be assessed in this specific industrial case by estimating the defect detection efficiency and image quality parameters. (authors)

  20. Technical and Non-Technical Issues Towards the Commercialisation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Chozas, Julia Fernandez

    . As a result, the thesis first identifies the phases that generally appear within WEC developments, it then determines the stages where there is a gap in research, and lastly, it analyses the identified key subjects. Accordingly, the thesis elaborates on seven areas: i. It examines regulatory frameworks...... and a collection of papers. The first part provides a brief history of wave energy, introduces the research topic, describes the different disciplines addressed in the thesis and relates them. The eight papers comprise the core part of the work. The papers address the research topic in different ways: from a legal......, social, technical and economic viewpoint, and from various WEC development stages. All the analyses are carried out from the perspective of device developers. The understanding of WEC developments has been central to the outline of the thesis, as it has formed the framework of the work. The developments...

  1. Mineral deposits research in Uruguay. Technical economic part

    International Nuclear Information System (INIS)

    Raabe, W.

    1959-01-01

    Technical researches, mineralogical and chemical analysis were carried out in Zapucay and Iman deposit located in Uruguay south America, as a result of that, researchers was described the mineral adherences of the deposits.

  2. Towards common technical standards

    International Nuclear Information System (INIS)

    Rahmat, H.; Suardi, A.R.

    1993-01-01

    In 1989, PETRONAS launched its Total Quality Management (TQM) program. In the same year the decision was taken by the PETRONAS Management to introduce common technical standards group wide. These standards apply to the design, construction, operation and maintenance of all PETRONAS installations in the upstream, downstream and petrochemical sectors. The introduction of common company standards is seen as part of an overall technical management system, which is an integral part of Total Quality Management. The Engineering and Safety Unit in the PETRONAS Central Office in Kuala Lumpur has been charged with the task of putting in place a set of technical standards throughout PETRONAS and its operating units

  3. Civilian Power Program. Part 1, Summary, Current status of reactor concepts

    Energy Technology Data Exchange (ETDEWEB)

    Author, Not Given

    1959-09-01

    This study group covered the following: delineation of the specific objectives of the overall US AEC civilian power reactor program, technical objectives of each reactor concept, preparation of a chronological development program for each reactor concept, evaluation of the economic potential of each reactor type, a program to encourage the the development, and yardsticks for measuring the development. Results were used for policy review by AEC, program direction, authorization and appropriation requests, etc. This evaluation encompassed civilian power reactors rated at 25 MW(e) or larger and related experimental facilities and R&D. This Part I summarizes the significant results of the comprehensive effort to determine the current technical and economic status for each reactor concept; it is based on the 8 individual technical status reports (Part III).

  4. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  5. Crustal Structure in the Western Part of Romania from Local Seismic Tomography

    Science.gov (United States)

    Zaharia, Bogdan; Grecu, Bogdan; Popa, Mihaela; Oros, Eugen; Radulian, Mircea

    2017-12-01

    The inner part of the Carpathians in Romania belongs to the Carpathians-Pannonian system bordered by the Eastern Carpathians to the north and east, Southern Carpathians to the south and Pannonian Basin to the west. It is a complex tectonic region with differential folding mechanisms, post-collisional kinematics, rheology and thermal properties, including within its area the Apuseni Mountains and the Transylvanian Basin. The purpose of this study is to map the 3-D structure of the crust over this region on the basis of local earthquake data. Input data were recorded during the South Carpathian Project (2009-2011), a successful collaboration between the Institute of Geophysics and Tectonics of the University of Leeds and the National Institute for Earth Physics (NIEP), Romania. A temporary array of 32 broadband seismic stations (10 CMG-40T, 8 CMG-3T and 14 CMG-6TD) was installed across the western part of Romania (spaced at 40 to 50 km intervals) during the project. In addition, 25 stations deployed in the eastern Hungary and Serbia was considered. P- and S-wave arrivals are identified for all the selected events (minimum 7 phases per event with reasonable signal/noise ratio). All the events are first relocated using Joint Hypocentre Determination (JHD) technique. Then the well-located events were inverted to determine the crustal structure using LOTOS algorithm. The lateral variations of the crustal properties as resulted from the tomography image are interpreted in correlation with the station corrections estimated by JHD algorithm and with the post-collisional evolution of the Carpathians-Pannonian system.

  6. Ambient seismic noise tomography for exploration seismology at Valhall

    Science.gov (United States)

    de Ridder, S. A.

    2011-12-01

    Permanent ocean-bottom cables installed at the Valhall field can repeatedly record high quality active seismic surveys. But in the absence of active seismic shooting, passive data can be recorded and streamed to the platform in real time. Here I studied 29 hours of data using seismic interferometry. I generate omni-directional Scholte-wave virtual-sources at frequencies considered very-low in the exploration seismology community (0.4-1.75 Hz). Scholte-wave group arrival times are inverted using both eikonal tomography and straight-ray tomography. The top 100 m near-surface at Valhall contains buried channels about 100 m wide that have been imaged with active seismic. Images obtained by ASNT using eikonal tomography or straight-ray tomography both contain anomalies that match these channels. When continuous recordings are made in real-time, tomography images of the shallow subsurface can be formed or updated on a daily basis, forming a very low cost near-surface monitoring system using seismic noise.

  7. World Wide Comparism of Technical and Vocational Education: Lessons for Nigerian Technical and Vocational Education Sector (I)

    Science.gov (United States)

    Ayeni, Abiodun Olumide

    2015-01-01

    This paper compared technical/vocational education in: Germany, Australia, Finland, Hong Kong, Hungary, India, Japan, South Korea, Mexico, and Nigeria, and found that technical/vocational education was given proper attention in countries considered except Nigeria, where it was handled with laissez faire attitude. Set-Up of Technical/Vocational…

  8. The Russia Corporate Governance Manual : Part I. Corporate Governance Introduced

    OpenAIRE

    International Finance Corporation; U.S. Department of Commerce

    2004-01-01

    The Russia corporate governance manual has been divided into and is published in six parts: (i) corporate governance introduced; (ii) good board practices; (iii) shareholder rights; (iv) information disclosure and transparency; (v) special focus section; and (vi) annexes model corporate governance documents. The first four parts contain chapters that focus on core corporate governance issu...

  9. Single photon emission computed tomography with N-isopropyl-p-[123I] iodoamphetamine in dementia of the Alzheimer type

    International Nuclear Information System (INIS)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki; Yasui, Shinichi; Yuasa, Satoru; Shimizu, Akinori; Kurachi, Masayoshi; Seki, Hiroyasu; Fukuta, Tsutomu.

    1989-01-01

    Correlation between brain uptake of N-isopropyl-p-[I-123]iodoamphetamine (I-123 IMP), as shown on single photon emission computed tomography (SPECT) scans, and clinical stages was examined in 8 patients with Alzheimer type dementia. The patients were clinically staged as Stage I (3), Stage II (3), or Stage III (2). The count ratio of each cerebral lobe to the cerebellum was calculated on horizontal SPECT scans. Stage I patients had a decreased I-123 IMP uptake in the temporal and parietal lobes. The decreased uptake in these areas became marked in Stage II patients, with diffusely slight uptake of I-123 IMP in the brain. In Stage III patients, the uptake of I-123 IMP was markedly decreased in the whole brain, including temporal, parietal, and frontal lobes. For five patients of Stage II and III, bilateral differences in the cerebral hemispheres were observed, corresponding to neurologic symptoms. Iodine-123 IMP SPECT was thus considered useful in clinically evaluating Alzheimer type dementia and in determining degenerative process of this disease. (Namekawa, K)

  10. Planning and conducting meetings effectively, part I: planning a meeting.

    Science.gov (United States)

    Harolds, Jay

    2011-12-01

    Meetings are held by leaders for many purposes, including conveying information, raising morale, asking for opinions, brain storming, making people part of the problem-solving process, building trust, getting to a consensus, and making decisions. However, many meetings waste time, some undermine the leader's power, and some decrease morale. Part I of this series of articles gives some tips on basic planning for decision-making meetings. Part II of this series of articles analyzes selected components of decision-making meetings. Part III of this series will be on how the chairperson keeps decision-making meetings on track to make them efficient and productive.

  11. Technical recommendations for bilateral comparison in diagnosis radiology: part 2

    International Nuclear Information System (INIS)

    Peixoto, J.G.P.; Almeida, C.E.V. de

    2015-01-01

    The conventional radiology (≈70%), mammography(≈4%) and Computer Tomography (≈2%) will be in charge of this bilateral comparison. We could found the users ionization chambers, reference and radiations conditions, agenda and the comparison budget. The partial results will be presentation at metrology and medical physics congress. (author)

  12. 45 CFR Appendix A to Part 1211 - Standards for Examiners

    Science.gov (United States)

    2010-10-01

    ... SERVICE VOLUNTEER GRIEVANCE PROCEDURES Pt. 1211, App. A Appendix A to Part 1211—Standards for Examiners An..., professional, investigative, or technical work which has demonstrated the possession of: (i) The personal... confidence of others. (iii) A good working knowledge of: The relationship between volunteer administration...

  13. Ethical and technical considerations for the creation of cell lines in the head & neck and tissue harvesting for research and drug development (Part II: Ethical aspects of obtaining tissue specimens

    Directory of Open Access Journals (Sweden)

    Upile Tahwinder

    2009-04-01

    Full Text Available Abstract Background Although much has been published for the development of cell lines, these were lab based and developed for scientific technical staff. Objective of review We discuss the ethical implications of tissue retention and present a generic consent form (Part II. We also present a simple and successful protocol for the development of cell lines and tissue harvesting for the clinical scientist (Part I. Conclusion Consent is also more proximate and assurance can be given of appropriate usage. Ethical questions concerning tissue ownership are in many institutions raised during the current consenting procedure. We provide a robust ethical framework, based on the current legislation, which allows clinicians to be directly involved in cell and tissue harvesting.

  14. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    International Nuclear Information System (INIS)

    Koh, Kwang Joon; Kim, Kyung A

    2011-01-01

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  15. Inter laboratory comparison on Computed Tomography for industrial applications in the slaughterhouses

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; Christensen, Lars Bager; Cantatore, Angela

    2014-01-01

    An intercomparison on X-ray Computed Tomography (CT) for industrial applications in the slaughterhouses was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial...

  16. Muons tomography applied to geosciences and volcanology

    Energy Technology Data Exchange (ETDEWEB)

    Marteau, J., E-mail: marteau@ipnl.in2p3.fr [Institut de Physique Nucleaire de Lyon (UMR CNRS-IN2P3 5822), Universite Lyon 1, Lyon (France); Gibert, D.; Lesparre, N. [Institut de Physique du Globe de Paris (UMR CNRS 7154), Sorbonne Paris Cite, Paris (France); Nicollin, F. [Geosciences Rennes (CNRS UMR 6118), Universite Rennes 1, Bat. 15 Campus de Beaulieu, 35042 Rennes cedex (France); Noli, P. [Universita degli studi di Napoli Federico II and INFN sez. Napoli (Italy); Giacoppo, F. [Laboratory for High Energy Physics, University of Bern, SidlerStrasse 5, CH-3012 Bern (Switzerland)

    2012-12-11

    Imaging the inner part of large geological targets is an important issue in geosciences with various applications. Different approaches already exist (e.g. gravimetry, electrical tomography) that give access to a wide range of information but with identified limitations or drawbacks (e.g. intrinsic ambiguity of the inverse problem, time consuming deployment of sensors over large distances). Here we present an alternative and complementary tomography method based on the measurement of the cosmic muons flux attenuation through the geological structures. We detail the basics of this muon tomography with a special emphasis on the photo-active detectors.

  17. Generation and focusing of pulsed intense ion beams. Technical progress report, 20 August 1981-30 September 1982

    International Nuclear Information System (INIS)

    Hammer, D.A.; Kusse, B.R.; Sudan, R.N.

    1983-07-01

    The progress on this contract is described in two parts. The first deals with the technical operation of the LION accelerator which is the exact equivalent to one line of PBFA-I. The second part is concerned with the experimental results on the ion diode mounted at the front end of the LION accelerator

  18. Optimal experiment design for quantum state tomography: Fair, precise, and minimal tomography

    International Nuclear Information System (INIS)

    Nunn, J.; Smith, B. J.; Puentes, G.; Walmsley, I. A.; Lundeen, J. S.

    2010-01-01

    Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al.[R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of 'minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.

  19. Technical and surgical aspects of the sphenopalatine ganglion (SPG) microstimulator insertion procedure

    DEFF Research Database (Denmark)

    Assaf, A T; Hillerup, S; Rostgaard, J

    2016-01-01

    into the pterygopalatine fossa (PPF) is presented herein. Technical aspects include detailed descriptions of the preoperative planning using computed tomography or cone beam computed tomography scans for presurgical digital microstimulator insertion into the patient-specific anatomy and intraoperative verification......), and removal (n=5). This SPG microstimulator insertion procedure has sequelae comparable to other oral cavity procedures including tooth extractions, sinus surgery, and dental implant placement. Twenty-five of 29 subjects (86%) completing a self-assessment questionnaire indicated that the surgical effects were...

  20. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...

  1. 16 CFR Appendix I to Part 305 - Heating Performance and Cost for Central Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... RULEâ) Pt. 305, App. I Appendix I to Part 305—Heating Performance and Cost for Central Air Conditioners... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Heating Performance and Cost for Central Air Conditioners I Appendix I to Part 305 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC...

  2. Ventilation distribution in rats: Part I - The effect of gas composition as measured with electrical impedance tomography

    Directory of Open Access Journals (Sweden)

    Dunster Kimble R

    2012-09-01

    Full Text Available Abstract The measurement of ventilation distribution is currently performed using inhaled tracer gases for multiple breath inhalation studies or imaging techniques to quantify spatial gas distribution. Most tracer gases used for these studies have properties different from that of air. The effect of gas density on regional ventilation distribution has not been studied. This study aimed to measure the effect of gas density on regional ventilation distribution. Methods Ventilation distribution was measured in seven rats using electrical impedance tomography (EIT in supine, prone, left and right lateral positions while being mechanically ventilated with either air, heliox (30% oxygen, 70% helium or sulfur hexafluoride (20% SF6, 20% oxygen, 60% air. The effect of gas density on regional ventilation distribution was assessed. Results Gas density did not impact on regional ventilation distribution. The non-dependent lung was better ventilated in all four body positions. Gas density had no further impact on regional filling characteristics. The filling characteristics followed an anatomical pattern with the anterior and left lung showing a greater impedance change during the initial phase of the inspiration. Conclusion It was shown that gas density did not impact on convection dependent ventilation distribution in rats measured with EIT.

  3. PIO I-II tendencies. Part 2. Improving the pilot modeling

    Directory of Open Access Journals (Sweden)

    Ioan URSU

    2011-03-01

    Full Text Available The study is conceived in two parts and aims to get some contributions to the problem ofPIO aircraft susceptibility analysis. Part I, previously published in this journal, highlighted the mainsteps of deriving a complex model of human pilot. The current Part II of the paper considers a properprocedure of the human pilot mathematical model synthesis in order to analyze PIO II typesusceptibility of a VTOL-type aircraft, related to the presence of position and rate-limited actuator.The mathematical tools are those of semi global stability theory developed in recent works.

  4. Applications of technical fusion in uroradiology; Einsatzmoeglichkeiten der technischen Fusion in der Uroradiologie

    Energy Technology Data Exchange (ETDEWEB)

    Aigner, F.; Zordo, T. de; Junker, D. [Medical University Innsbruck (Austria). Radiology; Pallwein-Prettner, L. [Sisters of Charity Hospital, Linz (Austria). Radiology

    2015-05-15

    Technical fusion is defined as the ultrasound-guided navigation through a previously generated 3 D imaging dataset such as a computed tomography (CT) or magnetic resonance imaging (MRI). This technique allows for moving the fused CT/MRI datasets synchroneously with the real-time ultrasound in the same plane. Established and furthermore not yet described applications, the technical principles and the limitations of this promising technique will be introduced.

  5. Measurements of computed tomography dose index for axial and spiral CT scanners

    International Nuclear Information System (INIS)

    Breiki, G; Abbas, Y.; Diab, H.M.; Gomaa, M

    2007-01-01

    The energy deposited in the patient by the rotating x-ray beam in computed tomography produces more uniform absorbed dose values within the section of imaged tissue than those produced in conventional radiological procedures. The dose values within a specific section are determined by factors such as voltage, current, scan field, rotation angle, filtration, collimation, and section thickness and spacing. This study is a part of extensive project, aiming to investigate practice of computed tomography at various hospitals and to implement a Reference Dose Levels (RDLs) to routine CT examinations in Egypt. The dosimetric quantities proposed in the European Guidelines (EG) for CT are weighted computed tomography dose index (CTDI w ) for a single slice and dose-length product (DLP) for a complete examination. Patient-related data as well as technical parameters for head, chest, abdomen and pelvis examinations were collected for seven CT scanners in public and private hospitals.Dose measurements were performed for both axial and spiral models for a range of CT examinations using CT dosimetry head and body phantoms, and ion chamber designed for CT dosimetry. The determined CTDI w and DLP values were compared with the European Commission reference dose levels (ECRDLs) and also with some international survey results. Mean values of CTDI w had a range of 36-69 m Gy with average 55 m Gy for head, and 11-35 mGy with average 23 mGy for chest, abdomen and pelvis examinations. The current reference CTDI w values are 60 m Gy for adult head and 25 m Gy for adult Abdomen

  6. Positron emission tomography in the management of cervix cancer patients

    International Nuclear Information System (INIS)

    Bonardel, G.; Gontier, E.; Soret, M.; Dechaud, C.; Fayolle, M.; Foehrenbach, H.; Chargari, C.; Bauduceau, O.

    2009-01-01

    Since its introduction in clinical practice in the 1990 s, positron emission tomography (PET), usually with 18 F-fluoro-2-deoxy-D-glucose ( 18 F-F.D.G.), has become an important imaging modality in patients with cancer. For cervix carcinoma, F.D.G.-PET is significantly more accurate than computed tomography (CT) and is recommended for loco-regional lymph node and extra pelvic staging. The metabolic dimension of the technique provides additional prognostic information. Ongoing studies now concentrate on more advanced clinical applications, such as the planning of radiotherapy, the response evaluation after the induction of therapy, the early detection of recurrence. Technical innovations, such as PET cameras with better spatial resolution and hybrid positron emission tomography/computed tomography (PET-CT), available now on the whole territory, provide both anatomic and metabolic information in the same procedure. From the point of view of biological metabolism, new radiopharmaceutical probes are being developed. Those hold promise for future refinements in this field. This article reviews the current applications of F.D.G.-PET in patients with cervix cancer. (authors)

  7. Californium Multiplier. Part I. Design for neutron radiography

    International Nuclear Information System (INIS)

    Crosbie, K.L.; Preskitt, C.A.; John, J.; Hastings, J.D.

    1982-01-01

    The Californium Multiplier (CFX) is a subcritical assembly of enriched uranium surrounding a californium-252 neutron source. The function of the CFX is to multiply the neutrons emitted by the source to a number sufficient for neutron radiography. The CFX is designed to provide a collimated beam of thermal neutrons from which the gamma radiation is filtered, and the scattered neutrons are reduced to make it suitable for high resolution radiography. The entire system has inherent safety features, which provide for system and personnel safety, and it operates at moderate cost. In Part I, the CFX and the theory of its operation are described in detail. Part II covers the performance of the Mound Facility CFX

  8. Project GICC-Rhone Final report of part I

    International Nuclear Information System (INIS)

    2002-12-01

    The project aims to give an evaluation of the impacts on the french Rhone basin, of the climatic change resulting of a double of the CO 2 content in the atmosphere (possible in 2050). This report gives an evaluation of the researches progress. It describes the topic of the part I, the hydrological simulations realized and the analysis of the hydrological impacts. It provides also recommendations for the part II. The following topics are presented: the objectives of the project; the data and the atmospheric scenari construction methods on the Rhone basin under the climatic change; the used hydrological models; the results analysis in terms of hydrogeological impacts; the limits of the approach; and a bibliography. (A.L.B.)

  9. 46 CFR Table I to Part 150 - Alphabetical List of Cargoes

    Science.gov (United States)

    2010-10-01

    ... cargo name), see Caustic potash solution 5 2 CPS Potassium oleate 34 POE Potassium salt of polyolefin... Sodium polyacrylate solution 43 2 Sodium salt of Ferric hydroxyethylethylenediaminetriacetic acid... 46 Shipping 5 2010-10-01 2010-10-01 false Alphabetical List of Cargoes I Table I to Part 150...

  10. Dosimetry and technical radiation protection at the RA in 1974; Dozimetrija i tehnicka zastita od zracenja kod reaktora RA u 1974. godini

    Energy Technology Data Exchange (ETDEWEB)

    Ninkovic, M [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1975-01-15

    This report include the analysis of the dosimetry and technical radiation protection results collected during 1974. The first part shows the data about the fundamental exposure to radiation and the statistical review of the total number of measurements. The following are included as well: measured values of radioactive gases and aerosol contents in air; contamination level of surfaces, clothes and uncovered parts of the staff bodies. Analysis of the personnel exposure is presented in the second part of the report. It was stated that the maximum individual external dose was 2.13R, and the exposure dose was 1/5 lower than of the annual dose limit for 90% of the exposed personnel. It was estimated that that the internal contamination is negligible compared to the external contamination. This statement was based on the frequency of tasks in the contaminated zones, undertaken control and protection measures, as well as on the evaluation of the expected internal contamination. Comparative evaluation of the occupational exposures is given for the past five years. This showed that the exposure in 1974 was lower than during previous years. The third part of the report covers the numerical data about the quantity of the collected radioactive waste, total size of contaminated and decontaminated surfaces and number of decontaminated objects. A brief analysis of the accidents occurred during this year under regular reactor operating conditions, maintenance and repair is given at the end. It was stated that there has been no accident that would cause exposure higher than the prescribed limits or any significant contamination of the working space or environment. Maximum individual dose was 1.4 R, and contamination of the uncovered parts of the bodies was about 6 MDNK (maximum permissible contamination level) [Serbo-Croat] U ovom radu prikazani su rezultati sakupljeni u toku godine u okviru dozimetrijske kontrole i tehnicke zastite kod reaktora. U prvom delu rada izlozeni su

  11. FOREX trading strategy formation using technical analysis

    OpenAIRE

    Klimavičius, Domas

    2010-01-01

    FOREX technical analysis indicators, their characteristics and capabilities are researched in this final master thesis. The main goal of this thesis is to determine if technical analysis indicators can recognise patterns in price movements and if they can predict future price movement. The first part of the thesis presents with FOREX theoretical aspects, its characteristics and participants. In the second part of the thesis FOREX analysis tools are overviewed, focusing on technical analysis. ...

  12. Simultaneous 99mTC and 123I Dual-Isotope Brain Striatal Phantom Single Photon Emission Computed Tomography: Validation of 99mTC-Trodat-1 and 123I-IBZM Simultaneous Dopamine System Brain Imaging

    OpenAIRE

    Pan-Fu Kao; Shiaw-Pyng Wey; An-Shoei Yang

    2009-01-01

    [2[[2-[[[3-(4-chlorophenyl)-8-methyl-8-azabicyclo[3,2,1]-oct-2-yl]-methyl](2-mercaptoethyl)amino]ethyl]amino]ethanethiolato(3-)-N2,N2′,S2,S2]oxo-[1R-exo-exo)])-[99mTc]-technetium (99mTc-TRODAT-1) and 123I-iodobenzamide (123I-IBZM) are radiotracers for brain dopamine preand postsynaptic neuron imaging. The purpose of this study was to evaluate imaging parameters and crossed energy interference using simultaneous single photon emission computed tomography (SPECT) 99mTc and 123I data acquisition...

  13. Commercial cyclotrons. Part I: Commercial cyclotrons in the energy range 10 30 MeV for isotope production

    Science.gov (United States)

    Papash, A. I.; Alenitsky, Yu. G.

    2008-07-01

    A survey of commercial cyclotrons for production of medical and industrial isotopes is presented. Compact isochronous cyclotrons which accelerate negative hydrogen ions in the energy range 10 30 MeV have been widely used over the last 25 years for production of medical isotopes and other applications. Different cyclotron models for the energy range 10 12 MeV with moderate beam intensity are used for production of 11C, 13N, 15O, and 18F isotopes widely applied in positron emission tomography. Commercial cyclotrons with high beam intensity are available on the market for production of most medical and industrial isotopes. In this work, the physical and technical parameters of different models are compared. Possibilities of improving performance and increasing intensity of H- beams up to 2 3 mA are discussed.

  14. CIFOL: Case-intensional first order logic. (I) Toward a theory of sorts

    NARCIS (Netherlands)

    Belnap, Nuel; Müller, Thomas

    2012-01-01

    This is Part I of a two-part essay introducing case-intensional first-order logic (CIFOL), an easy-to-use, uniform, powerful, and useful combination of first order logic with modal logic resulting from philosophical and technical modifications of Bressan’s General interpreted modal calculus (Yale

  15. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  16. Uncommon primary tumors of the orbit diagnosed by computed tomography-guided core needle biopsy: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Matushita Junior, Joao Paulo Kawaoka; Bitencourt, Almir Galvao Vieira; Amoedo, Mauricio Kauark; Barbosa, Paula Nicole Vieira; Chojniak, Rubens, E-mail: almirgvb@yahoo.com.br [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil). Dept. de Imagem; Neves, Flavia Branco Cerqueira Serra [Hospital do Servidor Publico Estadual, Sao Paulo, SP (Brazil). Div. de Oftalmologia

    2014-11-15

    Computed tomography-guided percutaneous biopsy is a safe and effective alternative method for evaluating selected intra-orbital lesions where the preoperative diagnosis is important for the therapeutic planning. The authors describe two cases of patients with uncommon primary orbital tumors whose diagnosis was obtained by means of computed tomography-guided core needle biopsy, with emphasis on the technical aspects of the procedure. (author)

  17. Role of single photon emission computed tomography/computed tomography in diagnostic iodine-131 scintigraphy before initial radioiodine ablation in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Agrawal, Kanhaiyalal; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2005-01-01

    The study was performed to evaluate the incremental value of single photon emission computed tomography/computed tomography (SPECT/CT) over planar radioiodine imaging before radioiodine ablation in the staging, management and stratification of risk of recurrence (ROR) in differentiated thyroid cancer (DTC) patients. Totally, 83 patients (21 male, 62 female) aged 17–75 (mean 39.9) years with DTC were included consecutively in this prospective study. They underwent postthyroidectomy planar and SPECT/CT scans after oral administration of 37–114 MBq iodine-131 (I-131). The scans were interpreted as positive, negative or suspicious for tracer uptake in the thyroid bed, cervical lymph nodes and sites outside the neck. In each case, the findings on planar images were recorded first, without knowledge of SPECT/CT findings. Operative and pathological findings were used for postsurgical tumor–node–metastasis staging. The tumor staging was reassessed after each of these two scans. Single photon emission computed tomography/computed tomography localized radioiodine uptake in the thyroid bed in 9/83 (10.8%) patients, neck nodes in 24/83 (28.9%) patients and distant metastases in 8/83 (9.6%) patients in addition to the planar study. Staging was changed in 8/83 (9.6%), ROR in 11/83 (13.2%) and management in 26/83 (31.3%) patients by the pretherapy SPECT/CT in comparison to planar imaging. SPECT/CT had incremental value in 32/83 patients (38.5%) over the planar scan. Single photon emission computed tomography/computed tomography is feasible during a diagnostic I-131 scan with a low amount of radiotracer. It improved the interpretation of pretherapy I-131 scintigraphy and changed the staging and subsequent patient management

  18. The use of computed tomography in brain damage testing

    International Nuclear Information System (INIS)

    De Villiers, J.F.K.

    1980-01-01

    The article deals with the diagnosis of brain damage by the use of computerized tomography - especially referring to the injuries of boxers. Three conditions may be evaluated with computerized tomography: i) fenestration of the septum pellucidum; ii) cortical atrophy; and, iii) cerebral atrophy. It also appears that computerized tomography has a place in the evaluation of injuries sustained in the ring, as well as the detection of accelerated ageing of the brain or atrophy

  19. Computerized tomography of renal parenchymal disturbance following nephrolithotomy

    International Nuclear Information System (INIS)

    Fukuoka, Hiroshi; Ishizuka, Eiichi; Fukushima, Shuji.

    1983-01-01

    Staghorn calculi were removed by nephrolithotomy with the one-layer interrupted parenchymal suture method designed by Taguchi and renal parenchymal disturbance following the operation were evaluated by computerized tomography. Twenty kidneys in 17 cases were examined pre and postoperatively for changes in the incised and sutured part of the renal parenchyma. The postoperative CT scanning demonstrated the low density areas following enhancement and depression of the parenchyma. These changes were classified into the following 3 patterns: Type I-no changes were observed in the parenchyma, or a linear low density area was found (5 kidneys, 25.0%); type II-a long, narrow strip of low density area was found in accord with the excised and sutured part (5 kidneys, 25.0%); and type III-a wedge-shaped low density area or depression of the parenchyma was found (10 kidneys, 50.0%). The length of the parenchymal incision was analysed with reference to these patterns. The length of type I was significantly shorter than that of type II or III (p<0.05). Th e clamping time of the renal pedicle in type I was also shorter than that in type II and III, but the differences did not reach a statistically significant level. Type II pattern frequently was found shortly after the operation. It is, however, undeniable that type II may tramsform to type III. (J.P.N.)

  20. Technical evaluation of RETS-required reports for the Edwin I. Hatch Nuclear Plant, Units 1 and 2

    International Nuclear Information System (INIS)

    Young, T.E.; Magleby, E.H.

    1985-01-01

    A review of the reports required by federal regulations and the plant-specific Radiological Effluent Technical Specifications (RETS) for operations conducted during 1983 was performed. The periodic reports reviewed for the Edwin I. Hatch Nuclear Plant were the Annual Radiological Environmental Operating Report for 1983 and the Semiannual Radioactive Effluent Release Reports for 1983. The principal review guidelines were the plant's specific RETS, NUREG-0133, ''Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants'', and NRC Guidance on the Review of the Process Control Programs. The Licensee's submitted reports were found to be reasonably complete and consistent with the review guidelines. 7 refs

  1. The socio-technical system and nuclear safety

    International Nuclear Information System (INIS)

    Stefanescu, Petre; Mihailescu, Nicolae; Dragusin, Octavian

    1999-01-01

    In the field of nuclear safety there have been defined notions like 'technical factors' and 'human factors'. The technical factors depend on designing and manufacturing of components/equipment, actually depend on the people's work. The study of human factors consists in analyzing and recommending the terms that allow an individual to be a reliable and safety agent. Accordingly, he/she is placed in working conditions corresponding to human abilities, associating the means of three levels: - designing, i.e. the action upon the technical system and upon work organization; - correction, i.e. the action upon the evolution of the technical system and organizing; - formation/training, i.e. action upon operators. The paper presents a characterization of the socio-technical system and on this basis discusses the issue of individual adjustment to the socio-technical system and reciprocally, the issue of the socio-technical system adjustment to the individual. Concepts as: ergonomics, physical medium, man/machine interface and support of the operator, man/machine task sharing, the work organizing are put in relation with the central subject, the nuclear safety

  2. Non-commutative tomography and signal processing

    International Nuclear Information System (INIS)

    Mendes, R Vilela

    2015-01-01

    Non-commutative tomography is a technique originally developed and extensively used by Professors M A Man’ko and V I Man’ko in quantum mechanics. Because signal processing deals with operators that, in general, do not commute with time, the same technique has a natural extension to this domain. Here, a review is presented of the theory and some applications of non-commutative tomography for time series as well as some new results on signal processing on graphs. (paper)

  3. Dual-Energy Computed Tomography in Stroke Imaging: Technical and Clinical Considerations of Virtual Noncontrast Images for Detection of the Hyperdense Artery Sign.

    Science.gov (United States)

    Winklhofer, Sebastian; Vittoria De Martini, Ilaria; Nern, Chrisitian; Blume, Iris; Wegener, Susanne; Pangalu, Athina; Valavanis, Antonios; Alkadhi, Hatem; Guggenberger, Roman

    The technical feasibility of virtual noncontrast (VNC) images from dual-energy computed tomography (DECT) for the detection of the hyperdense artery sign (HAS) in ischemic stroke patients was investigated. True noncontrast (TNC) scans of 60 patients either with or without HAS (n = 30 each) were investigated. Clot presence and characteristics were assessed on VNC images from DECT angiography and compared with TNC images. Clot characterization included the level of confidence for diagnosing HAS, a qualitative clot burden score, and quantitative attenuation (Hounsfield unit [HU]) measurements. Sensitivity, specificity, and accuracy of VNC for diagnosing HAS were 97%, 90%, and 93%, respectively. No significant differences were found regarding the diagnostic confidence (P = 0.18) and clot burden score (P = 0.071). No significant HU differences were found among vessels with HAS in VNC (56 ± 7HU) and TNC (57 ± 8HU) (P = 0.691) images. Virtual noncontrast images derived from DECT enable an accurate detection and characterization of HAS.

  4. Patient surface doses in computerized tomography examinations

    International Nuclear Information System (INIS)

    Vekic, B; Kovacevic, S.; Ranogajec-Komor, M.; Duvnjak, N.; Marusic, P.; Anic, P.; Dolencic, P.

    1996-01-01

    The diagnostic value of computerized tomography has increased due to very rapid technical advances in both equipment and techniques. When the CT scanners were introduced, a significant problem for the specification of the radiation dose imparted to the patient undergoing CT examination has been created. In CT, the conditions of exposure are quite different from those in conventional X-ray imaging. CT procedure involves the continuous tomography of thin layers. Some of these layers touch each other while others overlap. The radiation doses received by patients can vary considerably. In addition to the radiation from the collimated primary beam, patients are exposed to significant scattered doses in unpredictable amounts. Every effort should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The aims of this work were to determine the surface doses delivered to various organs of patients during various computerized tomography examinations (head, thorax, kidney, abdomen and pelvis). Particular attention was directed to the precise determination of doses received by the eyes (during CT of head) and gonads (during CT of pelvis and lower abdomen) since these organs can be near or even in the primary X-ray beam

  5. Electric capacitance tomography and two-phase flow for the nuclear reactor safety analysis

    International Nuclear Information System (INIS)

    Lee, Jae Young

    2008-01-01

    Recently electric capacitance tomography has been developed to be used in the analysis of two-phase flow. Although its electric field is not focused as the hard ray tomography such as the X-ray or gamma ray, its convenience of easy access to the system and easy maintenance due to no requirement of radiation shielding benefits us in its application in the two-phase flow study, one of important area in the nuclear safety analysis. In the present paper, the practical technologies in the electric capacitance tomography are represented in both parts of hardware and software. In the software part, both forward problem and inverse problem are discussed and the method of regularization. In the hardware part, the brief discussion of the electronics circuits is made which provides femto farad resolution with a reasonable speed (150 frame/sec for 16 electrodes). Some representative ideal cases are studied to demonstrate its potential capability for the two-phase flow analysis. Also, some variations of the tomography such as axial tomography, and three dimensional tomography are discussed. It was found that the present ECT is expected to become a useful tool to understand the complicated three dimensional two-phase flow which may be an important feature to be equipped by the safety analysis codes. (author)

  6. 32 CFR Appendix D to Part 286 - DD Form 2086-1, “Record of Freedom of Information (FOI) Processing Cost for Technical Data”

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false DD Form 2086-1, âRecord of Freedom of Information (FOI) Processing Cost for Technical Dataâ D Appendix D to Part 286 National Defense Department of... FREEDOM OF INFORMATION ACT PROGRAM REGULATION Pt. 286, App. D Appendix D to Part 286—DD Form 2086-1...

  7. Patient surface doses in computerized tomography examinations

    International Nuclear Information System (INIS)

    Vekic, B.; Kovacevic, S.; Ranogajec Komor, M.; Duvnjak, N.; Marusic, P.; Anic, P.; Dolencic, P.

    1996-01-01

    Computed tomography (CT) has become a major source of the population exposure to diagnostic x-rays, and acknowledge of the doses delivered by the CT equipment has become very important. Considerable efforts should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The conditions of exposure in CT are quite different from dose in conventional x-ray imaging. This has required the development of specific techniques for assessing patient dose from CT. The aims of this work were to determine the dose delivered to various organs of patients undergoing computed tomography of abdomen, thorax, pelvis and kidney as measured on the surface of the body and to estimate the risk to the patients. Dosimetric measurements were performed at two different CT scanners (Siemens SOMATOM DR-H ver. HC-1 and Shimadzu SCT-4500TE). The dose absorbed by different organs (gonads, chest, thyroid and eye lens) and by the examined part of the body of 95 patients of various sex and age were measured with TLD-700. The doses absorbed by different organs during the diagnostic CT examination of the body depend on the technical parameters, such as the number of scan, mAs, the thickness of scans, scanning times, tube voltage and other characteristics, some of each depend on the type and severity of illness. Clinical parameters, such as patient size and composition, and patient cooperation with regard to the control and motion, also influence the dose and the image quality. The highest dose measured in this study (89.19 mGy) was delivered to kidney during CT examination of this organ. (author)

  8. Transonic Airfoil Flow Simulation. Part I: Mesh Generation and Inviscid Method

    Directory of Open Access Journals (Sweden)

    Vladimir CARDOS

    2010-06-01

    Full Text Available A calculation method for the subsonic and transonic viscous flow over airfoil using thedisplacement surface concept is described. Part I presents a mesh generation method forcomputational grid and a finite volume method for the time-dependent Euler equations. The inviscidsolution is used for the inviscid-viscous coupling procedure presented in the Part II.

  9. Technical Manual. The ACT®

    Science.gov (United States)

    ACT, Inc., 2014

    2014-01-01

    This manual contains technical information about the ACT® college readiness assessment. The principal purpose of this manual is to document the technical characteristics of the ACT in light of its intended purposes. ACT regularly conducts research as part of the ongoing formative evaluation of its programs. The research is intended to ensure that…

  10. PET/MRI: Technical challenges and recent advances

    International Nuclear Information System (INIS)

    Jung, Jin Ho; Choi, Yong; Im, Ki Chun

    2016-01-01

    Integrated positron emission tomography (PET)/magnetic resonance imaging (MRI), which can provide complementary functional and anatomical information about a specific organ or body system at the molecular level, has become a powerful imaging modality to understand the molecular biology details, disease mechanisms, and pharmacokinetics in animals and humans. Although the first experiment on the PET/MRI was performed in the early 1990s, its clinical application was accomplished in recent years because there were various technical challenges in integrating PET and MRI in a single system with minimum mutual interference between PET and MRI. This paper presents the technical challenges and recent advances in combining PET and MRI along with several approaches for improving PET image quality of the PET/MRI hybrid imaging system

  11. Quality of computerized tomography exams proposed by a quality certification program

    International Nuclear Information System (INIS)

    Carlos, Marcia Terezinha

    1999-01-01

    Brazilian College of Radiologists (CBR) is concerned about the quality of radiological practices in the country. Actions in direction of accreditation programmes and standardization of the performance in imaging modalities have been implemented. The first accreditation programme was in mammography. In Brazil, computed tomography spread all over the country. Due high radiation dose to the patient and the continuous technological development, an accreditation programme in CT practice is necessary. A pilot programme has been carried out in the area of Rio de Janeiro with the participation of 11 CT facilities with 12 CT units. The background information follows Document EUR 16262 E uropean Guidelines of Quality Criteria for Computed Tomography . Initially practice data were collected through structured interviews using a standardized questionnaire. In regard to the assessment of clinical image quality, two examinations were selected: brain general and abdomen general. Three radiologists specialized in computed tomography evaluated the image quality criteria from a sample of examinations from the participant facilities. Other aspects selected to the assessment of the overall performance are: technical parameters of the examinations; image physical parameters (noise, spatial resolution, sensitivity profile) and radiation dose. Radiation dose and image quality criteria were fulfilled by 7 of 12 brain general examinations analyzed and only 5 of 10 abdomen general examinations analyzed. At the moment, it was not possible to get a conclusion about image quality based on measurements of physical parameters. Other factors affecting overall image quality were: technical limitation of CT units and practitioners are not able to fully handle the technical parameters of the examination. Dose and image quality criteria shall be the basis of an accreditation programme in CT and Brazilian College of Radiology has to use the experience of this work to implement a programme at national

  12. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  13. Initial evaluation of 123I-5-I-R91150, a selective 5-HT2Aligand for single-photon emission tomography, in healthy human subjects

    International Nuclear Information System (INIS)

    Busatto, G.F.; Pilowsky, L.S.; Costa, D.C.; Mertens, J.; Terriere, D.; Ell, P.J.; Mulligan, R.; Travis, M.J.; Leysen, J.E.; Lui, D.; Gacinovic, S.; Waddington, W.; Lingford-Hughes, A.; Kerwin, R.W.

    1997-01-01

    The mapping of 5-HT 2 receptors in the brain using functional imaging techniques has been limited by a relative lack of selective radioligands. Iodine-123 labelled 4-amino-N-[1-[3-(4-fluorophenoxy)propyl]-4-methyl-4-piperidinyl]-5-iodo-2-methox ybenzamide ( 123 I-5-I-R91150 or 123 I-R93274) is a new ligand for single-photon emission tomography (SPET), with high affinity and selectivity for 5-HT 2A receptors. This study reports on preliminary 123 I-5-I-R91150 SPET, whole-body and blood distribution findings in five healthy human volunteers. Maximal brain uptake was approximately 2% of total body counts at 180 min post injection (p.i.). Dynamic SPET sequences were acquired with the brain-dedicated, single-slice multi-detector system SME-810 over 200 min p.i. Early peak uptake (at 5 min p.i.) was seen in the cerebellum, a region free from 5HT 2A receptors. In contrast, radioligand binding in the frontal cortex increased steadily over time, up to a peak at approximately 100-120 min p.i. Frontal cortex-cerebellum activity ratios reached values of 1.4, and remained stable from approximately 100 min p.i. onwards. Multi-slice SPET sequences showed a pattern of regional variation of binding compatible with the autoradiographic data on the distribution of 5-HT 2A receptors in humans (cerebral cortex >striatum >cerebellum). These findings suggest that 123 I-5-I-R91150 may be used for the imaging of 5-HT 2A receptors in the living human brain with SPET. (orig.). With 4 figs., 2 tabs

  14. SU-E-I-73: Clinical Evaluation of CT Image Reconstructed Using Interior Tomography

    International Nuclear Information System (INIS)

    Zhang, J; Ge, G; Winkler, M; Cong, W; Wang, G

    2014-01-01

    Purpose: Radiation dose reduction has been a long standing challenge in CT imaging of obese patients. Recent advances in interior tomography (reconstruction of an interior region of interest (ROI) from line integrals associated with only paths through the ROI) promise to achieve significant radiation dose reduction without compromising image quality. This study is to investigate the application of this technique in CT imaging through evaluating imaging quality reconstructed from patient data. Methods: Projection data were directly obtained from patients who had CT examinations in a Dual Source CT scanner (DSCT). Two detectors in a DSCT acquired projection data simultaneously. One detector provided projection data for full field of view (FOV, 50 cm) while another detectors provided truncated projection data for a FOV of 26 cm. Full FOV CT images were reconstructed using both filtered back projection and iterative algorithm; while interior tomography algorithm was implemented to reconstruct ROI images. For comparison reason, FBP was also used to reconstruct ROI images. Reconstructed CT images were evaluated by radiologists and compared with images from CT scanner. Results: The results show that the reconstructed ROI image was in excellent agreement with the truth inside the ROI, obtained from images from CT scanner, and the detailed features in the ROI were quantitatively accurate. Radiologists evaluation shows that CT images reconstructed with interior tomography met diagnosis requirements. Radiation dose may be reduced up to 50% using interior tomography, depending on patient size. Conclusion: This study shows that interior tomography can be readily employed in CT imaging for radiation dose reduction. It may be especially useful in imaging obese patients, whose subcutaneous tissue is less clinically relevant but may significantly increase radiation dose

  15. Three-dimensional fluorescence lifetime tomography

    International Nuclear Information System (INIS)

    Godavarty, Anuradha; Sevick-Muraca, Eva M.; Eppstein, Margaret J.

    2005-01-01

    Near-infrared fluorescence tomography using molecularly targeted lifetime-sensitive, fluorescent contrast agents have applications for early-stage cancer diagnostics. Yet, although the measurement of fluorescent lifetime imaging microscopy (FLIM) is extensively used in microscopy and spectroscopy applications, demonstration of fluorescence lifetime tomography for medical imaging is limited to two-dimensional studies. Herein, the feasibility of three-dimensional fluorescence-lifetime tomography on clinically relevant phantom volumes is established, using (i) a gain-modulated intensified charge coupled device (CCD) and modulated laser diode imaging system, (ii) two fluorescent contrast agents, e.g., Indocyanine green and 3-3'-Diethylthiatricarbocyanine iodide differing in their fluorescence lifetime by 0.62 ns, and (iii) a two stage approximate extended Kalman filter reconstruction algorithm. Fluorescence measurements of phase and amplitude were acquired on the phantom surface under different target to background fluorescence absorption (70:1, 100:1) and fluorescence lifetime (1:1, 2.1:1) contrasts at target depths of 1.4-2 cm. The Bayesian tomography algorithm was employed to obtain three-dimensional images of lifetime and absorption owing to the fluorophores

  16. MMX-I: A data-processing software for multi-modal X-ray imaging and tomography

    International Nuclear Information System (INIS)

    Bergamaschi, A; Medjoubi, K; Somogyi, A; Messaoudi, C; Marco, S

    2017-01-01

    Scanning hard X-ray imaging allows simultaneous acquisition of multimodal information, including X-ray fluorescence, absorption, phase and dark-field contrasts, providing structural and chemical details of the samples. Combining these scanning techniques with the infrastructure developed for fast data acquisition at Synchrotron Soleil permits to perform multimodal imaging and tomography during routine user experiments at the Nanoscopium beamline. A main challenge of such imaging techniques is the online processing and analysis of the generated very large volume (several hundreds of Giga Bytes) multimodal data-sets. This is especially important for the wide user community foreseen at the user oriented Nanoscopium beamline (e.g. from the fields of Biology, Life Sciences, Geology, Geobiology), having no experience in such data-handling. MMX-I is a new multi-platform open-source freeware for the processing and reconstruction of scanning multi-technique X-ray imaging and tomographic datasets. The MMX-I project aims to offer, both expert users and beginners, the possibility of processing and analysing raw data, either on-site or off-site. Therefore we have developed a multi-platform (Mac, Windows and Linux 64bit) data processing tool, which is easy to install, comprehensive, intuitive, extendable and user-friendly. MMX-I is now routinely used by the Nanoscopium user community and has demonstrated its performance in treating big data. (paper)

  17. MMX-I: A data-processing software for multi-modal X-ray imaging and tomography

    Science.gov (United States)

    Bergamaschi, A.; Medjoubi, K.; Messaoudi, C.; Marco, S.; Somogyi, A.

    2017-06-01

    Scanning hard X-ray imaging allows simultaneous acquisition of multimodal information, including X-ray fluorescence, absorption, phase and dark-field contrasts, providing structural and chemical details of the samples. Combining these scanning techniques with the infrastructure developed for fast data acquisition at Synchrotron Soleil permits to perform multimodal imaging and tomography during routine user experiments at the Nanoscopium beamline. A main challenge of such imaging techniques is the online processing and analysis of the generated very large volume (several hundreds of Giga Bytes) multimodal data-sets. This is especially important for the wide user community foreseen at the user oriented Nanoscopium beamline (e.g. from the fields of Biology, Life Sciences, Geology, Geobiology), having no experience in such data-handling. MMX-I is a new multi-platform open-source freeware for the processing and reconstruction of scanning multi-technique X-ray imaging and tomographic datasets. The MMX-I project aims to offer, both expert users and beginners, the possibility of processing and analysing raw data, either on-site or off-site. Therefore we have developed a multi-platform (Mac, Windows and Linux 64bit) data processing tool, which is easy to install, comprehensive, intuitive, extendable and user-friendly. MMX-I is now routinely used by the Nanoscopium user community and has demonstrated its performance in treating big data.

  18. A Classification Method of Technical Security Controls for Digital I and C Systems in NPPs

    International Nuclear Information System (INIS)

    Song, J. G.; Lee, J. W.; Park, G. Y.; Kwon, K. C.; Lee, D. Y.; Lee, C. K.

    2012-01-01

    The instrumentation and control (I and C) systems in nuclear power plants (NPPs) are a key facility to monitor plant state, control plant devices, and prevent accidents. Recent I and C systems have been composed of digital systems in order to enhance the effectiveness of operation and maintenance of NPPs. An assessment method for the analysis of security controls is needed to respond to potential cyber attacks against digital I and C systems. RG 5.71 'Cyber Security Programs for Nuclear Facilities' published by U.S.NRC in 2010 presents a comprehensive set of security controls for NPPs. Although this document provides the requirements of security controls, a guidance describing which security controls should be applied to specific digital assets and how to implement them is still needed for the I and C system design and development. In this paper, a classification method of the technical security controls listed in RG 5.71 is proposed to provide a guide useful for the application of the controls during the design and implementation phases of I and C systems

  19. A Classification Method of Technical Security Controls for Digital I and C Systems in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Song, J. G.; Lee, J. W.; Park, G. Y.; Kwon, K. C.; Lee, D. Y.; Lee, C. K. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    The instrumentation and control (I and C) systems in nuclear power plants (NPPs) are a key facility to monitor plant state, control plant devices, and prevent accidents. Recent I and C systems have been composed of digital systems in order to enhance the effectiveness of operation and maintenance of NPPs. An assessment method for the analysis of security controls is needed to respond to potential cyber attacks against digital I and C systems. RG 5.71 'Cyber Security Programs for Nuclear Facilities' published by U.S.NRC in 2010 presents a comprehensive set of security controls for NPPs. Although this document provides the requirements of security controls, a guidance describing which security controls should be applied to specific digital assets and how to implement them is still needed for the I and C system design and development. In this paper, a classification method of the technical security controls listed in RG 5.71 is proposed to provide a guide useful for the application of the controls during the design and implementation phases of I and C systems

  20. Compilation of interim technical research memoranda. Volume I

    International Nuclear Information System (INIS)

    Shanahan, W.R.

    1984-04-01

    Four interim technical research memoranda are presented that describe the results of numerical simulations designed to investigate the dynamics of energetic plasma beams propagating across magnetic fields

  1. Three-dimensional multifunctional optical coherence tomography for skin imaging

    Science.gov (United States)

    Li, En; Makita, Shuichi; Hong, Young-Joo; Kasaragod, Deepa; Sasaoka, Tomoko; Yamanari, Masahiro; Sugiyama, Satoshi; Yasuno, Yoshiaki

    2016-02-01

    Optical coherence tomography (OCT) visualizes cross-sectional microstructures of biological tissues. Recent developments of multifunctional OCT (MF-OCT) provides multiple optical contrasts which can reveal currently unknown tissue properties. In this contribution we demonstrate multifunctional OCT specially designed for dermatological investigation. And by utilizing it to measure four different body parts of in vivo human skin, three-dimensional scattering OCT, OCT angiography, polarization uniformity tomography, and local birefringence tomography images were obtained by a single scan. They respectively contrast the structure and morphology, vasculature, melanin content and collagen traits of the tissue.

  2. Delivery Systems for Biopharmaceuticals. Part I: Nanoparticles and Microparticles.

    Science.gov (United States)

    Silva, Ana C; Lopes, Carla M; Lobo, José M S; Amaral, Maria H

    2015-01-01

    Pharmaceutical biotechnology has been showing therapeutic success never achieved with conventional drug molecules. Therefore, biopharmaceutical products are currently well-established in clinic and the development of new ones is expected. These products comprise mainly therapeutic proteins, although nucleic acids and cells are also included. However, according to their sensitive molecular structures, the efficient delivery of biopharmaceuticals is challenging. Several delivery systems (e.g. microparticles and nanoparticles) composed of different materials (e.g. polymers and lipids) have been explored and demonstrated excellent outcomes, such as: high cellular transfection efficiency for nucleic acids, cell targeting, increased proteins and peptides bioavailability, improved immune response in vaccination, and viability maintenance of microencapsulated cells. Nonetheless, important issues need to be addressed before they reach clinics. For example, more in vivo studies in animals, accessing the toxicity potential and predicting in vivo failure of these delivery systems are required. This is the Part I of two review articles, which presents the state of the art of delivery systems for biopharmaceuticals. Part I deals with microparticles and polymeric and lipid nanoparticles.

  3. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  4. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  5. 36 CFR 51.84 - What special terms must I know to understand this part?

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false What special terms must I know to understand this part? 51.84 Section 51.84 Parks, Forests, and Public Property NATIONAL PARK... § 51.84 What special terms must I know to understand this part? To understand this subpart specifically...

  6. Image quality assessment of three limited field-of-view cone-beam computed tomography devices in endodontics

    International Nuclear Information System (INIS)

    Tran, Michel

    2015-01-01

    Since the beginning of Cone Beam Computed Tomography (CBCT) in dento-maxillo-facial radiology, many CBCT devices with different technical aspects and characteristics were produced. Technical variations between CBCT and acquisition settings could involve image quality differences. In order to compare the performance of three limited field-of-view CBCT devices, an objective and subjective evaluation of image quality was carried out using an ex-vivo phantom, which combines both diagnostic and technical features. A significant difference in image quality was found between the five acquisition protocols of the study. (author) [fr

  7. Removing the Mystery of Entropy and Thermodynamics--Part I

    Science.gov (United States)

    Left, Harvey S.

    2012-01-01

    Energy and entropy are centerpieces of physics. Energy is typically introduced in the study of classical mechanics. Although energy in this context can be challenging, its use in thermodynamics and its connection with entropy seem to take on a special air of mystery. In this five-part series, I pinpoint ways around key areas of difficulty to…

  8. Late prosthetic graft infection after frozen elephant trunk presenting by haemoptysis and positive ¹⁸F-fluorodeoxyglucose-positron emission tomography/computed tomography.

    Science.gov (United States)

    Morjan, Mohammed; Ali, Khaldoun; Harringer, Wolfgang; El-Essawi, Aschraf

    2014-11-01

    In cardiothoracic surgery, prosthetic graft infection represents a diagnostic and therapeutic challenge. Although clinical assessment, imaging techniques and microbiological investigations are helpful, late graft infection can be difficult to identify using classical diagnostic tools. An aggressive surgical approach involving removal and replacement of all prosthetic materials is technically demanding but remains the best strategy to eradicate infection. Herein, we report a case of a late aortic graft infection, after frozen elephant trunk implantation with atypical presentation, diagnosed with (18)F-fluorodeoxyglucose-positron emission tomography and treated successfully through a radical surgical strategy. This case emphasizes the emerging diagnostic role of positron emission tomography and encourages the adoption of an aggressive surgical approach. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. HEART OF MYTH – HEART OF SCIENCE Part I

    Science.gov (United States)

    Bound Alberti, Fay

    2015-01-01

    This article explores the history and meanings of the heart and its diseases as aspects of the histories of science and emotion. Analyzing the twofold meanings of the heart as both bodily object and cultural symbol, it explores the reasons for the apparent conflict in meanings of the heart of science and the heart of emotion in Western medical culture since the 19th century. In Part I, a case study of the writer, economist, and philosopher Harriet Martineau is used to demonstrate and trace that conflict, while Part II highlights the manifold meanings of the heart both in the past and in the present. PMID:26167117

  10. Focus on Mentee-Mentor Relationships: The 10th Grade Implementation of iMentor's College Ready Program. Technical Appendices

    Science.gov (United States)

    Merrill, Lisa; Kang, David; Siman, Nina; Soltani, Jasmine

    2016-01-01

    This document presents the technical appendices that accompany the full report entitled:"Focus on Mentee-Mentor Relationships: The 10th Grade Implementation of iMentor's College Ready Program." The appendices include: (1) Mentor Survey Construct Items; (2) Qualative Data Collection and Analysis Methods; and (3) Methods for Estimating the…

  11. Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography.

    Science.gov (United States)

    Ludlow, John B; Walker, Cameron

    2013-12-01

    The increasing use of cone-beam computed tomography in orthodontics has been coupled with heightened concern about the long-term risks of x-ray exposure in orthodontic populations. An industry response to this has been to offer low-exposure alternative scanning options in newer cone-beam computed tomography models. Effective doses resulting from various combinations of field of view size and field location comparing child and adult anthropomorphic phantoms with the recently introduced i-CAT FLX cone-beam computed tomography unit (Imaging Sciences, Hatfield, Pa) were measured with optical stimulated dosimetry using previously validated protocols. Scan protocols included high resolution (360° rotation, 600 image frames, 120 kV[p], 5 mA, 7.4 seconds), standard (360°, 300 frames, 120 kV[p], 5 mA, 3.7 seconds), QuickScan (180°, 160 frames, 120 kV[p], 5 mA, 2 seconds), and QuickScan+ (180°, 160 frames, 90 kV[p], 3 mA, 2 seconds). Contrast-to-noise ratio was calculated as a quantitative measure of image quality for the various exposure options using the QUART DVT phantom. Child phantom doses were on average 36% greater than adult phantom doses. QuickScan+ protocols resulted in significantly lower doses than standard protocols for the child (P = 0.0167) and adult (P = 0.0055) phantoms. The 13 × 16-cm cephalometric fields of view ranged from 11 to 85 μSv in the adult phantom and 18 to 120 μSv in the child phantom for the QuickScan+ and standard protocols, respectively. The contrast-to-noise ratio was reduced by approximately two thirds when comparing QuickScan+ with standard exposure parameters. QuickScan+ effective doses are comparable with conventional panoramic examinations. Significant dose reductions are accompanied by significant reductions in image quality. However, this trade-off might be acceptable for certain diagnostic tasks such as interim assessment of treatment results. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc

  12. Single photon emission computerized tomography (SPECT)

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as 123 I and 99 Tc m that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  13. Single photon emission computerized tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as {sup 123}I and {sup 99}Tc{sup m} that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  14. Complex deformation in western Tibet revealed by anisotropic tomography

    Science.gov (United States)

    Zhang, Heng; Zhao, Junmeng; Zhao, Dapeng; Yu, Chunquan; Liu, Hongbing; Hu, Zhaoguo

    2016-10-01

    The mechanism and pattern of deformation beneath western Tibet are still an issue of debate. In this work we present 3-D P- and S-wave velocity tomography as well as P-wave radial and azimuthal anisotropy along the ANTILOPE-I profile and surrounding areas in western Tibet, which are determined by using a large number of P and S arrival-time data of local earthquakes and teleseismic events. Our results show that low-velocity (low-V) zones exist widely in the middle crust, whereas low-V zones are only visible in the lower crust beneath northwestern Tibet, indicating the existence of significant heterogeneities and complex flow there. In the upper mantle, a distinct low-V gap exists between the Indian and Asian plates. Considering the P- and S-wave tomography and P-wave azimuthal and radial anisotropy results, we interpret the gap to be caused mainly by shear heating. Depth-independent azimuthal anisotropy and high-velocity zones exist beneath the northern part of the study region, suggesting a vertically coherent deformation beneath the Tarim Basin. In contrast, tomographic and anisotropic features change with depth beneath the central and southern parts of the study region, which reflects depth-dependent (or decoupled) deformations there. At the northern edge of the Indian lithospheric mantle (ILM), P-wave azimuthal anisotropy shows a nearly east-west fast-velocity direction, suggesting that the ILM was re-built by mantle materials flowing to the north.

  15. Development of novel emission tomography system

    Science.gov (United States)

    Fu, Geng

    In recent years, small animals, such as mice and rats, have been widely used as subjects of study in biomedical research while molecular biology and imaging techniques open new opportunities to investigate disease model. With the help of medical imaging techniques, researchers can investigate underlying mechanisms inside the small animal, which are useful for both early diagnosis and treatment monitoring. Based on tracer principle single photon emission computed tomography (SPECT) has increased popularity in small animal imaging due to its higher spatial resolution and variety of single-photon emitting radionuclides. Since the image quality strongly depends on the detector properties, both scintillation and semiconductor detectors are under active investigation for high resolution X-ray and gamma ray photon detection. The desired detector properties include high intrinsic spatial resolution, high energy resolution, and high detection efficiency. In this thesis study, we have made extensive efforts to develop novel emission tomography system, and evaluate the use of both semiconductor and ultra-high resolution scintillation detectors for small animal imaging. This thesis work includes the following three areas. Firstly, we have developed a novel energy-resolved photon counting (ERPC) detector. With the benefits of high energy resolution, high spatial resolution, flexible detection area, and a wide dynamic range of 27--200keV, ERPC detector is well-suited for small animal SPECT applications. For prototype ERPC detector excellent imaging (˜350microm) and spectroscopic performance (4keV Co-57 122keV) has been demonstrated in preliminary study. Secondly, to further improve spatial resolution to hundred-micron level, an ultra-high resolution Intensified EMCCD (I-EMCCD) detector has been designed and evaluated. This detector consists of the newly developed electron multiplying CCD (EMCCD) sensor, columnar CsI(Tl) scintillator, and an electrostatic de-magnifier (DM) tube

  16. Positron emission tomography and migraine. Tomographie par emission de positons et migraine

    Energy Technology Data Exchange (ETDEWEB)

    Chabriat, H. (CEA, 91 - Orsay (France). Service Hospitalier Frederic Joliot)

    1992-04-01

    Positron emission tomography (PET) is a brain imaging technique that allows in vivo studies of numerous physiological parameters. There have been few PET studies in migraine patients. Cerebral blood flow changes with no variations in brain oxygen consumption have been reported in patients with prolonged neurologic manifestations during migraine attacks. Parenteral administration of reserpine during migraine headache has been followed by a fall in the overall cerebral uptake of glucose. The small sample sizes and a number of methodologic problems complicate the interpretation of these results. Recent technical advances and the development of new PET tracers can be expected to provide further insight into the pathophysiology of migraine. Today cerebral cortex 5 HT{sub 2} serotonin receptors can be studied in migraine patients with PET.

  17. Positron emission tomography in the management of cervix cancer patients; Tomographie par emission de positons dans la prise en charge des cancers du col de l'uterus

    Energy Technology Data Exchange (ETDEWEB)

    Bonardel, G.; Gontier, E.; Soret, M.; Dechaud, C.; Fayolle, M.; Foehrenbach, H. [Hopital d' Instruction des Armees du Val-de-Grace, Service de Medecine Nucleaire, 75 - Paris (France); Chargari, C.; Bauduceau, O. [Hopital d' Instruction des Armees du Val-de-Grace, Service de Radiotherapie, 75 - Paris (France)

    2009-10-15

    Since its introduction in clinical practice in the 1990 s, positron emission tomography (PET), usually with {sup 18}F-fluoro-2-deoxy-D-glucose ({sup 18}F-F.D.G.), has become an important imaging modality in patients with cancer. For cervix carcinoma, F.D.G.-PET is significantly more accurate than computed tomography (CT) and is recommended for loco-regional lymph node and extra pelvic staging. The metabolic dimension of the technique provides additional prognostic information. Ongoing studies now concentrate on more advanced clinical applications, such as the planning of radiotherapy, the response evaluation after the induction of therapy, the early detection of recurrence. Technical innovations, such as PET cameras with better spatial resolution and hybrid positron emission tomography/computed tomography (PET-CT), available now on the whole territory, provide both anatomic and metabolic information in the same procedure. From the point of view of biological metabolism, new radiopharmaceutical probes are being developed. Those hold promise for future refinements in this field. This article reviews the current applications of F.D.G.-PET in patients with cervix cancer. (authors)

  18. Clinical results with beta-methyl-p-(123I)iodophenylpentadecanoic acid, single-photon emission computed tomography in cardiac disease.

    Science.gov (United States)

    Nishimura, T; Uehara, T; Shimonagata, T; Nagata, S; Haze, K

    1994-01-01

    This study was undertaken to evaluate the relationships, between myocardial perfusion and metabolism. Simultaneous beta-methyl-p(123I)iodophenylpentadecanoic acid (123I-BMIPP) and thallium 201 myocardial single-photon emission computed tomography (SPECT) were performed in 25 patients with myocardial infarction (group A) and 16 patients with hypertrophic cardiomyopathy (group B). The severity scores of 123I-BMIPP and 201Tl myocardial SPECT images were evaluated semiquantitatively by segmental analysis. In Group A, dissociations between thallium- and 123I-BMIPP-imaged defects were frequently observed in patients with successful reperfusion compared with those with no reperfusion and those with reinfarction. In four patients with successful reperfusion, repeated 123I-BMIPP and 201Tl myocardial SPECT showed gradual improvement of the 123I-BMIPP severity score compared with the thallium severity score. In group B, dissociations between thallium- and 123I-BMIPP-imaged defects were also demonstrated in hypertrophic myocardium. In addition, nonhypertrophic myocardium also had decreased 123I-BMIPP uptake. In groups A and B, 123I-BMIPP severity scores correlated well with left ventricular function compared with thallium severity scores. These findings indicate that 123I-BMIPP is a suitable agent for the assessment of functional integrity, because left ventricular wall motion is energy dependent and 123I-BMIPP may reflect an aspect of myocardial energy production. This agent may be useful for the early detection and patient management of various heart diseases as an alternative to positron emission tomographic study.

  19. COST EFFECTIVE AND HIGH RESOLUTION SUBSURFACE CHARACTERIZATION USING HYDRAULIC TOMOGRAPHY

    Science.gov (United States)

    2017-08-01

    objective of this project is to provide the DoD and its remediation contractors with the HT technology for delineating the spatial distribution of...STATEMENT Approved for public release; distribution is unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Hydraulic Tomography ( HT ) is a high-resolution...performance of subsurface remedial actions at environmental sites. The good technical performance and cost-effectiveness of HT have been demonstrated in

  20. Technical considerations on scanning and image analysis for amyloid PET in dementia

    International Nuclear Information System (INIS)

    Akamatsu, Go; Ohnishi, Akihito; Aita, Kazuki; Ikari, Yasuhiko; Senda, Michio; Yamamoto, Yasuji

    2017-01-01

    Brain imaging techniques, such as computed tomography (CT), magnetic resonance imaging (MRI), single photon emission computed tomography (SPECT), and positron emission tomography (PET), can provide essential and objective information for the early and differential diagnosis of dementia. Amyloid PET is especially useful to evaluate the amyloid-β pathological process as a biomarker of Alzheimer's disease. This article reviews critical points about technical considerations on the scanning and image analysis methods for amyloid PET. Each amyloid PET agent has its own proper administration instructions and recommended uptake time, scan duration, and the method of image display and interpretation. In addition, we have introduced general scanning information, including subject positioning, reconstruction parameters, and quantitative and statistical image analysis. We believe that this article could make amyloid PET a more reliable tool in clinical study and practice. (author)

  1. Technical Considerations on Scanning and Image Analysis for Amyloid PET in Dementia.

    Science.gov (United States)

    Akamatsu, Go; Ohnishi, Akihito; Aita, Kazuki; Ikari, Yasuhiko; Yamamoto, Yasuji; Senda, Michio

    2017-01-01

    Brain imaging techniques, such as computed tomography (CT), magnetic resonance imaging (MRI), single photon emission computed tomography (SPECT), and positron emission tomography (PET), can provide essential and objective information for the early and differential diagnosis of dementia. Amyloid PET is especially useful to evaluate the amyloid-β pathological process as a biomarker of Alzheimer's disease. This article reviews critical points about technical considerations on the scanning and image analysis methods for amyloid PET. Each amyloid PET agent has its own proper administration instructions and recommended uptake time, scan duration, and the method of image display and interpretation. In addition, we have introduced general scanning information, including subject positioning, reconstruction parameters, and quantitative and statistical image analysis. We believe that this article could make amyloid PET a more reliable tool in clinical study and practice.

  2. Technical Agency in Practice

    DEFF Research Database (Denmark)

    Krummheuer, Antonia Lina

    2015-01-01

    ) description of hybrid networks in which human and non-human actants are granted agency without differentiating different kinds of agency, EMCA focuses on the member's perspectives and the situated construction of technical agency that is made relevant within an ongoing interaction. Based on an EMCA analysis......The paper combines the discussion of technical agency and hybrid networks of Actor-Network Theory (ANT) with an ethnomethodological/conversation analytical (EMCA) perspective on situated practices in which participants ascribe agency to technical artefacts. While ANT works with (ethnographic...... of three video recordings of situations in which technical agency is made relevant by the human participants, the paper demonstrates different ways in which agency is granted to technical artefacts. Human participants can treat a technology as communication partner, as an active part (and actant...

  3. I-RobCELL: the factory of the future for nuclear industry

    International Nuclear Information System (INIS)

    Nozais, D.; Larousse, B.

    2016-01-01

    The I-RobCELL project (Innovative Robotic Center with online Examination) is a concept of a totally automated cell for the production and control of small parts for the high-precision mechanical market. The I-RobCELL will play on 4 fields: 1) a totally digital driving of the fabrication process involving various fabrication processes for the same part, 2) the integration of non-destructive testing technologies based on ultrasound, 3) automated diagnostic of defects through the comparison between real-time measured values given by probes and references values stored in a database, and 4) on-line monitoring of the welding. The technology of ultrasonic testing without couplant substance between the transducer and the part to be tested, is being developed to be integrated to the I-RobCELL, other non-destructive testing like guided waves or X-ray tomography will be implemented in the future versions of the I-RobCELL. The I-RobCELL will occupy a 2-3 m"3 volume allowing a very accurate monitoring of the temperature and a high level of cleanliness. The I-RobCELL concept will prefigure the factory of the future. (A.C.)

  4. 25 CFR 547.1 - What is the purpose of this part?

    Science.gov (United States)

    2010-04-01

    ... Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM TECHNICAL STANDARDS FOR GAMING EQUIPMENT USED WITH THE PLAY OF CLASS II GAMES § 547.1 What is the purpose of this part? The Indian Gaming Regulatory Act, 25 U.S.C. 2703(7)(A)(i), permits the use of electronic, computer, or...

  5. Computed tomography with multidetectors in the diagnosis of coronary stenosis

    International Nuclear Information System (INIS)

    Lombo, Bernardo; Carvajal, Codos A; Tafur, Monica; Gomez, Rafael

    2007-01-01

    Coronary angiography that uses multislice spiral computed tomography is a noninvasive technique for the detection of coronary stenosis that has had significant improvements in recent years. The introduction of 16 and 64 row scanners, the development of synchronized scanning electrocardiogram and better reconstruction techniques permit higher spatial and temporal resolution that allows better identification of coronary plaques and significant obstructive coronary lesions. In the next years Multislice spiral computed tomography will continue maturing and it will become a useful non invasive diagnostic imaging tool for the diagnosis of coronary disease and will be integrated to the cardiologic management protocols. Our next review will be focused on the basic and technical aspects of the scanner, diagnostic performance and clinical applications of this new technology

  6. Patch-based anisotropic diffusion scheme for fluorescence diffuse optical tomography—part 1: technical principles

    International Nuclear Information System (INIS)

    Correia, Teresa; Arridge, Simon

    2016-01-01

    Fluorescence diffuse optical tomography (fDOT) provides 3D images of fluorescence distributions in biological tissue, which represent molecular and cellular processes. The image reconstruction problem is highly ill-posed and requires regularisation techniques to stabilise and find meaningful solutions. Quadratic regularisation tends to either oversmooth or generate very noisy reconstructions, depending on the regularisation strength. Edge preserving methods, such as anisotropic diffusion regularisation (AD), can preserve important features in the fluorescence image and smooth out noise. However, AD has limited ability to distinguish an edge from noise. In this two-part paper, we propose a patch-based anisotropic diffusion regularisation (PAD), where regularisation strength is determined by a weighted average according to the similarity between patches around voxels within a search window, instead of a simple local neighbourhood strategy. However, this method has higher computational complexity and, hence, we wavelet compress the patches (PAD-WT) to speed it up, while simultaneously taking advantage of the denoising properties of wavelet thresholding. The proposed method combines the nonlocal means (NLM), AD and wavelet shrinkage methods, which are image processing methods. Therefore, in this first paper, we used a denoising test problem to analyse the performance of the new method. Our results show that the proposed PAD-WT method provides better results than the AD or NLM methods alone. The efficacy of the method for fDOT image reconstruction problem is evaluated in part 2. (paper)

  7. Administrative Candidacy: A Process of New-Role Learning--Part I

    Science.gov (United States)

    Greenfield, William D., Jr.

    1977-01-01

    Reports the initial results of a longitudinal study of the organizational socialization of educational administrators. Part I claims that socialization through the life-cycle may be conceived as a series of learned interpersonal relationships through which individuals build up a repertoire of interpersonal responses that condition new…

  8. Optical coherence tomography--a new imaging method in ophthalmology.

    Science.gov (United States)

    Svorenova, I; Strmen, P; Olah, Z

    2010-01-01

    An improvement of examination methods in ophthalmology, technical digitalisation and knowledge of validity of examinations in various diseases contributes to early diagnostics, thereby leading to an opportunity for early treatment of eye disorders. Standard introduction of the so-called optical coherence tomography into the ophthamological clinical practice facilitated new options for a detailed analysis of pathological processes in the particular layers of the retina (Fig. 2, Ref. 5). Full Text (Free, PDF) www.bmj.sk.

  9. Biostatistics primer: part I.

    Science.gov (United States)

    Overholser, Brian R; Sowinski, Kevin M

    2007-12-01

    Biostatistics is the application of statistics to biologic data. The field of statistics can be broken down into 2 fundamental parts: descriptive and inferential. Descriptive statistics are commonly used to categorize, display, and summarize data. Inferential statistics can be used to make predictions based on a sample obtained from a population or some large body of information. It is these inferences that are used to test specific research hypotheses. This 2-part review will outline important features of descriptive and inferential statistics as they apply to commonly conducted research studies in the biomedical literature. Part 1 in this issue will discuss fundamental topics of statistics and data analysis. Additionally, some of the most commonly used statistical tests found in the biomedical literature will be reviewed in Part 2 in the February 2008 issue.

  10. CERN Technical Training: Autumn 2007 Course Catalogue

    CERN Multimedia

    2007-01-01

    The following course sessions are scheduled in the framework of the CERN Technical Training Program 2007. You may find the full updated Technical Training course programme in our web-catalogue. OFFICE SOFTWARE CERN EDMS MTF en pratique F 4.9 1/2 d WORD 2007 (Short Course III) - How to work with long documents E/F 14.9 1/2 d FrontPage 2003 - niveau 1 E/F 17-18.9 2 d WORD 2007 - Niveau1: ECDL F 20.-21-9 2 d ACCESS 2007 - Level 1: ECDL E 20-21.9 2 d EXCEL 2007 (Short Course I) - How to work with Formulae E/F 21.9 1/2 d CERN EDMS Introduction E 24.9 1 d Java 2 Enterprise Edition - Part 1: Web Applications E 24-25.9 2 d Outlook 2007 (Short Course II) - Calendar, Tasks and Notes E/F 28.9 1/2 d Outlook 2007 (Short Course III) - Meeting and Delegation ...

  11. Eleventh annual meeting, Bologna, Italy, 17-20 April 1978. Summary report. Part I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1978-06-01

    The Summary Report of the Eleventh Annual Meeting of the IAEA International Working Group on Fast Reactors contains the Minutes of the Meeting (Part I); the papers which review the national programmes in the field of LMFBRs and other presentations at the Meeting (Part II); and the discussions on the review of the national programmes (Part III)

  12. Design of an integrated I and C system

    International Nuclear Information System (INIS)

    Lee, C. K.; Oh, I. S.; Kim, D. H.

    2004-08-01

    The final goal of this project is to develop an integrated I and C systems, and through this project the localized equipment and systems being developed should secure the safety, the reliability, their applicability and technical competitiveness. As well, the technical interfaces among sub-projects should be maintained for integration. The results of this project are as following ; 1. Development of an integrated I and C system architecture: Development of the design concepts for KNICS and the design requirements for each I and C system, Development of the design requirements of control systems based on DCS, Design of the communication systems, Design of the interface signals among systems and analysis of traffic load for networks, Conceptual design of measuring and monitoring systems, Review of the structure of computer systems for information processing, Development of architectures for each system and KOICS 2. Technological integration and management of projects: Development of evaluation criteria for DCS and network systems, Evaluation of the DCS prototype, Design review of KNICS protection system, Review of the functions and design requirements of I and C systems in NPP, Analysis of the I and C system H/W in NPP and the APR1400 I and C system design, Review of the technology criteria and the regulatory trend for licensing issues, Extracting items for preparing the technical description of I and C systems, a part of proposal to invitation to bid (ITB), Planning for KNICS to be of practical use The results of this project will be applied as design bases during the development of 2nd phase KNICS. As well it is expected that the results of this project will be finally applied for the technical self-reliance of component design and manufacturing of NPP I and C systems

  13. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[123I]iodoamphetamine (123I-IMP) in schizophrenia and atypical psychosis

    International Nuclear Information System (INIS)

    Suga, Hidemichi; Hayashi, Takuji; Mitsugi, Ohara

    1994-01-01

    As a basis for possible classification of schinzophrenic psychoses into schizophrenia and atypical psychosis, we studied the brain functional differences among 16 schizophrenic patients, 16 atypical psychosis patients and 16 healthy volunteers by single photon emission computed tomography (SPECT) using N-isopropyl-p-[ 123 I] iodoamphetamine. As a result, schizophrenics showed hypofrontality. On the other hand, atypical psychotics had no such hypofrontality but showed a reduced uptake rate in the right thalamic region. No influence of sex, duration of illness and medication was confirmed by the findings. The results suggest that schizophrenics might have some lesions in the frontal regions, whereas atypical psychotics might have no such lesions, but dysfunction in the right thalamic region. Consequently, the SPECT findings as least indicate possibly different etiologies for schizophrenia and atypical psychosis. (author)

  14. KNK I Test Program, Final Report Part 1

    International Nuclear Information System (INIS)

    Kathol, W.

    1976-01-01

    The compact sodium cooled nuclear reactor KNK I of the Karlsruhe Research Center reached full power for the first time in February 1974. The goal of KNK I is to collect experience for the construction and operation of larger reactors, such as SNR 300. In order to deepen these experiences, a test program was drawn up and conducted from 1973 until 1975 within the framework of R and D work on the development of fast breeder reactors. The program included individual tasks concerning reactor design, safety instrumentation, irradiation and post-examination as well as behavior of components during operation. The performance of the tests was essentially governed by the licensing procedure imposed under the atomic energy act for the construction and operation of nuclear facilities. This report is the first part of the final report of the test program

  15. PARAMETRIC DIAGNOSTICS OF THE CENTRIFUGAL SUPERCHARGER'S TECHNICAL CONDITION DURING OPERATION

    Directory of Open Access Journals (Sweden)

    Regina A. Khuramshina

    2017-01-01

    Full Text Available Abstract. Objectives The main aim is to develop a mathematical model of a centrifugal compressor and carry out a parametric diagnostics of a centrifugal supercharger's technical condition during operation. Methods  A model is proposed for calculating the thermodynamic properties of natural gas, reducing the parameters of a centrifugal compressor to the initial conditions and to the rotation frequency, as well as the integral indicators of the supercharger's technical state. The technical state of the gas path of the centrifugal supercharger of the compressor unit is determined by the parametric diagnostic method. Results  The software implementation of the mathematical model of centrifugal compressor is carried out using a DVIGwT PC. The analysis of calculations indicates that the model is appropriate, with the error being due to taking into account the properties of iso-butane and i-hexane, in contrast with the VNIIGAZ technique. The evaluation studies of a centrifugal compressor's state are indicative of the presence or absence of its defects. Conclusion  Among a number of the diagnostic methods for evaluating a centrifugal supercharger, the most effective is vibrodiagnostics. However, the search for malfunctions and nascent defects in the flowing part of the centrifugal compressor cannot be limited only to vibrodiagnostic data, which provides about 60% of the reliable information about the state of the gas-air tract. About 20% of the compressor's malfunctions and approximately half of the dangerous modes of the supercharger's flow-through part is detected using thermogasdynamic parametric analysis (parametric diagnostics. The main difficulty of the control over the technical state of the flow-through part of the centrifugal supercharger is in the complication of the quantitative evaluation of the processes taking place in the supercharger, which leads to problems in providing reliable diagnosis during a reasonable period of time.

  16. Development of axial tomography technique for the study of steam explosion

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Young; Seo, S. W.; You, S. [Handong Golbal Univ., Pohang (Korea, Republic of)

    2006-05-15

    In this report, axial tomography applying to steam explosion is implemented. When steam explosion experiment is performed, we have seen the difficulty with physical modeling due to the complex phenomena of generated steam, propagation of shock wave and bubble breakup and coalescence. Hence, the uncertainty due to these phenomena is occurred. The fast and global measurement of the steam distribution is imperative to understand the complex phenomena performed during the steam explosion, KAERI have developed the fast and global measuring instrument to monitor such phenomena of axial steam distribution. Generally, X-ray is used as measuring method, but this method is very expensive and has limited measurement area. So we need new method that can substitute X-ray method and in this research, ECT method is replaced. The research is performed dividing within two parts: Software and Hardware. In the software part, the electric field analysis code and algorithm for inverse projection were developed. And, in the hardware part, capacitance measurement circuit is developed to measure up to fF level. Operable axial tomography was analyzed with concept design of axial tomography appropriate to steam explosion accident and analysis code for axial electric field analysis and inverse algorithm were developed, moreover, designing signal analysis system for axial tomography was performed.

  17. Mechanical Engineering Department. Technical review

    Energy Technology Data Exchange (ETDEWEB)

    Simecka, W.B.; Condouris, R.A.; Talaber, C. (eds.)

    1980-01-01

    The Mechanical Engineering Department Technical Review is published to (1) inform the readers of various technical activities within the Department, (2) promote exchange of ideas, and (3) give credit to the personnel who are achieving the results. The report is formatted into two parts: technical achievements and publication abstracts. The first is divided into eight sections, one for each Division in the Department providing the reader with the names of the personnel and the Division accomplishing the work.

  18. Mechanical engineering department technical review

    International Nuclear Information System (INIS)

    Carr, R.B.; Denney, R.M.

    1981-01-01

    The Mechanical Engineering Department Technical Review is published to: (1) inform the readers of various technical activities within the department, (2) promote exchange of ideas, and (3) give credit to the personnel who are achieving the results. The report is formatted into two parts: technical acievements and publication abstracts. The first is divided into eight sections, one for each division in the department providing the reader with the names of the personnel and the division accomplishing the work

  19. Mechanical Engineering Department Technical Review

    International Nuclear Information System (INIS)

    Carr, R.B.; Denney, R.M.

    1981-01-01

    The Mechanical Engineering Department Technical Review is published to inform readers of various technical activities within the Department, promote exchange of ideas, and give credit to personnel who are achieving the results. The report is presented in two parts: technical achievements and publication abstracts. The first is divided into seven sections, each of which reports on an engineering division and its specific activities related to nuclear tests, nuclear explosives, weapons, energy systems, engineering sciences, magnetic fusion, and materials fabrication

  20. Mechanical Engineering Department. Technical review

    International Nuclear Information System (INIS)

    Simecka, W.B.; Condouris, R.A.; Talaber, C.

    1980-01-01

    The Mechanical Engineering Department Technical Review is published to (1) inform the readers of various technical activities within the Department, (2) promote exchange of ideas, and (3) give credit to the personnel who are achieving the results. The report is formatted into two parts: technical achievements and publication abstracts. The first is divided into eight sections, one for each Division in the Department providing the reader with the names of the personnel and the Division accomplishing the work

  1. Development and prospects of X-ray computerized tomography. I

    International Nuclear Information System (INIS)

    Dobes, V.

    1985-01-01

    The history and developmental trends are described of X-ray computerized tomography (CT) as are its applications in clinical practise. Suitable criteria and economic aspects are proposed for the choice of CT systems. The types are listed and described of X-ray CT systems, including brain, whole-body, mobile and special systems. A table is given showing available specifications (types of detectors, X-ray source, resolution, configuration, scan angles, scan fields, image reconstruction, etc.) for machines by different companies. (M.D.)

  2. Research using small tokamaks. Proceedings of a technical committee meeting

    International Nuclear Information System (INIS)

    1997-09-01

    The technical reports in these proceedings were presented at the IAEA Technical Committee Meeting on research Using Small Tokamaks, held in Ahmedabad, India, 6-7 December 1995. The purpose of this annual meeting is to provide a forum for the exchange of information on various small and medium sized plasma experiments, not only for tokamaks. The potential benefits of these research programmes are to: test theories, such as effects of the plasma rotation; check empirical scalings, such as density limits; develop fusion technology hardware; develop plasma diagnostics; such as tomography; and to train scientists, engineers, technicians, and students, particularly in developing IAEA Member States

  3. The Development of Nanotechnologies and Advanced Materials Industry in Science and Entrepreneurship: Socioeconomic and Technical Indicators. A Case Study of Latvia (Part Two)

    Science.gov (United States)

    Geipele, I.; Geipele, S.; Staube, T.; Ciemleja, G.; Zeltins, N.

    2016-10-01

    Part two of the in-depth scientific study clarifies the significant social and technical indicators of the development of nano-field at the macro, micro, and meso development levels of the economic environment in Latvia in the framework of the given theme. The analytical assessment of numerical change in socioeconomic and technical factors clearly demonstrates the interaction of nano-field with the development of science and manufacture, as found out in the study. The identified indicators are proposed to use for research, comparison and implementation in any other country of the world.

  4. The Development of Nanotechnologies and Advanced Materials Industry in Science and Entrepreneurship: Socioeconomic and Technical Indicators. A Case Study of Latvia (Part Two

    Directory of Open Access Journals (Sweden)

    Geipele I.

    2016-10-01

    Full Text Available Part two of the in-depth scientific study clarifies the significant social and technical indicators of the development of nano-field at the macro, micro, and meso development levels of the economic environment in Latvia in the framework of the given theme. The analytical assessment of numerical change in socioeconomic and technical factors clearly demonstrates the interaction of nano-field with the development of science and manufacture, as found out in the study. The identified indicators are proposed to use for research, comparison and implementation in any other country of the world.

  5. Striatal [123I]β-CIT SPECT and prefrontal cognitive functions in Parkinson's disease

    International Nuclear Information System (INIS)

    Mueller, U.; Waechter, T.; Barthel, H.; Reuter, M.; Cramon, D.Y. von

    2000-01-01

    Twenty non-demented patients with idiopathic Parkinson's disease (PD) underwent single photon emission computed tomography (SPECT) with [ 123 I]β-CIT to further investigate the contribution of nigrostriatal dysfunction to cognitive and motor deficits. Compared to matched controls PD patients showed normal verbal intelligence, short-term memory and phasic alertness. There were significant (p 123 I]β-CIT SPECT. These results support the view that the striatum is part of a neuronal network that is mediating prefrontal cognitive functions. (author)

  6. Empirical Psycho-Aesthetics and Her Sisters: Substantive and Methodological Issues--Part I

    Science.gov (United States)

    Konecni, Vladimir J.

    2012-01-01

    Empirical psycho-aesthetics--an interdisciplinary field with a long tradition--is approached in this two-part article from two directions, in each case with several objectives. Part I, in this issue of "JAE", is devoted to the first direction, which is mainly definitional and organizational: the objectives are to present an outline of the field's…

  7. Technical basis for evaluating electromagnetic and radio-frequency interference in safety-related I ampersand C systems

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.

    1994-04-01

    This report discusses the development of the technical basis for the control of upsets and malfunctions in safety-related instrumentation and control (I ampersand C) systems caused by electromagnetic and radio-frequency interference (EMI/RFI) and power surges. The research was performed at the Oak Ridge National Laboratory (ORNL) and was sponsored by the USNRC Office of Nuclear Regulatory Research (RES). The motivation for research stems from the safety-related issues that need to be addressed with the application of advanced I ampersand C systems to nuclear power plants. Development of the technical basis centered around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems known to be the source(s) of EMI/RFI and power surges. First, good EMC design and installation practices need to be established to control the impact of interference sources on nearby circuits and systems. These EMC good practices include circuit layouts, terminations, filtering, grounding, bonding, shielding, and adequate physical separation. Second, an EMI/RFI test and evaluation program needs to be established to outline the tests to be performed, the associated test methods to be followed, and carefully formulated acceptance criteria based on the intended environment to ensure that the circuit or system under test meets the recommended guidelines. Third, a program needs to be developed to perform confirmatory tests and evaluate the surge withstand capability (SWC) and of I ampersand C equipment connected to or installed in the vicinity of power circuits within the nuclear power plant. By following these three steps, the design and operability of safety-related I ampersand C systems against EMI/RFI and power surges can be evaluated, acceptance criteria can be developed, and appropriate regulatory guidance can be provided

  8. Computed tomography in malignant primary bone tumours

    International Nuclear Information System (INIS)

    Kersjes, W.; Harder, T.; Haeffner, P.

    1990-01-01

    The importance of computed tomography is examined in malignant primary bone tumours using a strongly defined examination group of 13 Patients (six Ewing's-sarcomas, five osteosarcomas, one chondrosarcoma and one spindle-shaped cell sarcoma). Computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, CT is especially suitable for therapy planning and evaluating response to therapy. CT does not provide sufficient diagnostic information to determine dignity and exact diagnosis of bone tumours. (orig.) [de

  9. Preliminary results of local earthquake tomography around Bali, Lombok, and Sumbawa regions

    Energy Technology Data Exchange (ETDEWEB)

    Nugraha, Andri Dian, E-mail: nugraha@gf.itb.ac.id; Puspito, Nanang T; Yudistira, Tedi [Global Geophysical Reserach Group, Faculty of Mining and Petroleum Engineering, Institute of Technology Bandung, JlGanesa 10, Bandung, 40132 (Indonesia); Kusnandar, Ridwan; Sakti, Artadi Pria [Meteorological, Climatological, and Geophysical Agency (MCGA) of Indonesian, Jakarta (Indonesia)

    2015-04-24

    Bali, Sumbawa, and Lombok regions are located in active tectonic influence by Indo-Australia plate subducts beneath Sunda plate in southern part and local back-arc thrust in northern part the region. Some active volcanoes also lie from eastern part of Java, Bali, Lombok and Sumbawa regions. Previous studies have conducted subsurface seismic velocity imaging using regional and global earthquake data around the region. In this study, we used P-arrival time from local earthquake networks compiled by MCGA, Indonesia within time periods of 2009 up to 2013 to determine seismic velocity structure and simultaneously hypocenter adjustment by applying seismic tomography inversion method. For the tomographic inversion procedure, we started from 1-D initial velocity structure. We evaluated the resolution of tomography inversion results through checkerboard test and calculating derivative weigh sum. The preliminary results of tomography inversion show fairly clearly high seismic velocity subducting Indo-Australian and low velocity anomaly around volcano regions. The relocated hypocenters seem to cluster around the local fault system such as back-arc thrust fault in northern part of the region and around local fault in Sumbawa regions. Our local earthquake tomography results demonstrated consistent with previous studies and improved the resolution. For future works, we will determine S-wave velocity structure using S-wave arrival time to enhance our understanding of geological processes and for much better interpretation.

  10. The Creativity of Natural Selection? Part I: Darwin, Darwinism, and the Mutationists.

    Science.gov (United States)

    Beatty, John

    2016-12-01

    This is the first of a two-part essay on the history of debates concerning the creativity of natural selection, from Darwin through the evolutionary synthesis and up to the present. Here I focus on the mid-late nineteenth century to the early twentieth, with special emphasis on early Darwinism and its critics, the self-styled "mutationists." The second part focuses on the evolutionary synthesis and some of its critics, especially the "neutralists" and "neo-mutationists." Like Stephen Gould, I consider the creativity of natural selection to be a key component of what has traditionally counted as "Darwinism." I argue that the creativity of natural selection is best understood in terms of (1) selection initiating evolutionary change, and (2) selection being responsible for the presence of the variation it acts upon, for example by directing the course of variation. I consider the respects in which both of these claims sound non-Darwinian, even though they have long been understood by supporters and critics alike to be virtually constitutive of Darwinism.

  11. Calculus of Elementary Functions, Part I. Student Text. Revised Edition.

    Science.gov (United States)

    Herriot, Sarah T.; And Others

    This course is intended for students who have a thorough knowledge of college preparatory mathematics, including algebra, axiomatic geometry, trigonometry, and analytic geometry. This text, Part I, contains the first five chapters of the course and two appendices. Chapters included are: (1) Polynomial Functions; (2) The Derivative of a Polynomial…

  12. 5 CFR 340.203 - Technical assistance.

    Science.gov (United States)

    2010-01-01

    ... part-time employment practices; (3) Development of special recruitment and selection techniques for...-TIME CAREER EMPLOYMENT (PART-TIME, SEASONAL, ON-CALL, AND INTERMITTENT) Regulatory Requirements-Part-Time Employment § 340.203 Technical assistance. (a) The Office of Personnel Management shall provide...

  13. New technical solutions in nanotechnology. Part 3

    Directory of Open Access Journals (Sweden)

    IVANOV Leonid Alexeevich

    2016-08-01

    Full Text Available The new technical solutions including inventions in the area of nanotechnology and nanomaterials are efficiently applied in communal and housing services as well as in construction and other joint fields. The invention «Nanomodified epoxy binder for composite materials (RU 2584013» refers to the production of composite materials based on fiber fillers and nanomodified epoxy binder and can be used for manufacture of glass-fiber tubes and other articles for which winding method is used and which are employed in heat networks, hot water supply with delivery method, water supply systems where the temperature can achieve 150°С. Nanomodified epoxy binder for composite materials includes epoxy diane resin and amine hardening agent. The technical result is shorter period of binder hardening, increased heat-resistance and strength characteristics of cured compositions, extended assortment of epoxy compositions with improved technological and performance properties. The specialists may be also interested in the following inventions: composite material based on alloys of the system sn-sb-cu and the method to produce it (RU 2585588, nanomodified epoxy sphere plastic (RU 2587454, the method to produce glass articles with conductive surface (RU 2586123, the method to produce carbon nanotubes with controlled surface density (RU 2569548, solar energy plant (RU 2586034, the method to purify surface and undeground water from titanium and its compounds by means of carbon nanotubes and ultrasound (RU 2575029, elastomeric nanocomposites, compositions of nanocomposites and the methods to produce them (RU 2561170, the method to set heat-resistant pressure sensor based on thin-film nano- and microelectromechanical system (RU 2581454, the method to determine cytotoxicity of nanomaterials based on zinc oxide (RU 2587630, the method to produce nanocores of manganese dioxide (RU 2587439, the method to determine material characteristics by means of nanoindentatio (RU

  14. Marketing in the E-Business World, Parts I & II | Smith | LBS ...

    African Journals Online (AJOL)

    Marketing in the E-Business World, Parts I & II. ... Open Access DOWNLOAD FULL TEXT ... of many of Americas largest companies gather at the Waldorf Astoria Hotel in New York City for the Conference Boards Annual Marketing Conference.

  15. MMX-I: data-processing software for multimodal X-ray imaging and tomography.

    Science.gov (United States)

    Bergamaschi, Antoine; Medjoubi, Kadda; Messaoudi, Cédric; Marco, Sergio; Somogyi, Andrea

    2016-05-01

    A new multi-platform freeware has been developed for the processing and reconstruction of scanning multi-technique X-ray imaging and tomography datasets. The software platform aims to treat different scanning imaging techniques: X-ray fluorescence, phase, absorption and dark field and any of their combinations, thus providing an easy-to-use data processing tool for the X-ray imaging user community. A dedicated data input stream copes with the input and management of large datasets (several hundred GB) collected during a typical multi-technique fast scan at the Nanoscopium beamline and even on a standard PC. To the authors' knowledge, this is the first software tool that aims at treating all of the modalities of scanning multi-technique imaging and tomography experiments.

  16. SU-E-I-52: Validation of Multi-Frequency Electrical Impedance Tomography Using Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, K; Liu, F; Krishnan, K [BC Cancer Agency, Surrey, BC (United Kingdom)

    2014-06-01

    Purpose: Multi-frequency EIT has been reported to be a potential tool in distinguishing a tissue anomaly from background. In this study, we investigate the feasibility of acquiring functional information by comparing multi-frequency EIT images in reference to the structural information from the CT image through fusion. Methods: EIT data was acquired from a slice of winter melon using sixteen electrodes around the phantom, injecting a current of 0.4mA at 100, 66, 24.8 and 9.9 kHz. Differential EIT images were generated by considering different combinations of pair frequencies, one serving as reference data and the other as test data. The experiment was repeated after creating an anomaly in the form of an off-centered cavity of diameter 4.5 cm inside the melon. All EIT images were reconstructed using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) package in 2-D differential imaging mode using one-step Gaussian Newton minimization solver. CT image of the melon was obtained using a Phillips CT Scanner. A segmented binary mask image was generated based on the reference electrode position and the CT image to define the regions of interest. The region selected by the user was fused with the CT image through logical indexing. Results: Differential images based on the reference and test signal frequencies were reconstructed from EIT data. Result illustrated distinct structural inhomogeneity in seeded region compared to fruit flesh. The seeded region was seen as a higherimpedance region if the test frequency was lower than the base frequency in the differential EIT reconstruction. When the test frequency was higher than the base frequency, the signal experienced less electrical impedance in the seeded region during the EIT data acquisition. Conclusion: Frequency-based differential EIT imaging can be explored to provide additional functional information along with structural information from CT for identifying different tissues.

  17. SU-E-I-52: Validation of Multi-Frequency Electrical Impedance Tomography Using Computed Tomography

    International Nuclear Information System (INIS)

    Kohli, K; Liu, F; Krishnan, K

    2014-01-01

    Purpose: Multi-frequency EIT has been reported to be a potential tool in distinguishing a tissue anomaly from background. In this study, we investigate the feasibility of acquiring functional information by comparing multi-frequency EIT images in reference to the structural information from the CT image through fusion. Methods: EIT data was acquired from a slice of winter melon using sixteen electrodes around the phantom, injecting a current of 0.4mA at 100, 66, 24.8 and 9.9 kHz. Differential EIT images were generated by considering different combinations of pair frequencies, one serving as reference data and the other as test data. The experiment was repeated after creating an anomaly in the form of an off-centered cavity of diameter 4.5 cm inside the melon. All EIT images were reconstructed using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) package in 2-D differential imaging mode using one-step Gaussian Newton minimization solver. CT image of the melon was obtained using a Phillips CT Scanner. A segmented binary mask image was generated based on the reference electrode position and the CT image to define the regions of interest. The region selected by the user was fused with the CT image through logical indexing. Results: Differential images based on the reference and test signal frequencies were reconstructed from EIT data. Result illustrated distinct structural inhomogeneity in seeded region compared to fruit flesh. The seeded region was seen as a higherimpedance region if the test frequency was lower than the base frequency in the differential EIT reconstruction. When the test frequency was higher than the base frequency, the signal experienced less electrical impedance in the seeded region during the EIT data acquisition. Conclusion: Frequency-based differential EIT imaging can be explored to provide additional functional information along with structural information from CT for identifying different tissues

  18. Radial lens distortion correction with sub-pixel accuracy for X-ray micro-tomography.

    Science.gov (United States)

    Vo, Nghia T; Atwood, Robert C; Drakopoulos, Michael

    2015-12-14

    Distortion correction or camera calibration for an imaging system which is highly configurable and requires frequent disassembly for maintenance or replacement of parts needs a speedy method for recalibration. Here we present direct techniques for calculating distortion parameters of a non-linear model based on the correct determination of the center of distortion. These techniques are fast, very easy to implement, and accurate at sub-pixel level. The implementation at the X-ray tomography system of the I12 beamline, Diamond Light Source, which strictly requires sub-pixel accuracy, shows excellent performance in the calibration image and in the reconstructed images.

  19. Testing objects in Computerized Axial Tomography. Contributions to the Spanish Protocol on quality control in radiodiagnostics

    International Nuclear Information System (INIS)

    Villaescusa, J.I.; Campayo, J.M.

    1995-01-01

    In the provisional version of the Spanish Protocol about the technical aspects of Quality Control in Radiodiagnostic,SEFM-SEPR 1993, it is dedicated a section to Computerized Axial tomography, establishing a total of eleven technical parameters of the equipment for examination. The present work describes the practical use of the Protocol using various types of Test Object. The authors also propose new tests that should be considered in the final version of the Spanish Protocol. (Author)

  20. Improved specimen reconstruction by Hilbert phase contrast tomography.

    Science.gov (United States)

    Barton, Bastian; Joos, Friederike; Schröder, Rasmus R

    2008-11-01

    The low signal-to-noise ratio (SNR) in images of unstained specimens recorded with conventional defocus phase contrast makes it difficult to interpret 3D volumes obtained by electron tomography (ET). The high defocus applied for conventional tilt series generates some phase contrast but leads to an incomplete transfer of object information. For tomography of biological weak-phase objects, optimal image contrast and subsequently an optimized SNR are essential for the reconstruction of details such as macromolecular assemblies at molecular resolution. The problem of low contrast can be partially solved by applying a Hilbert phase plate positioned in the back focal plane (BFP) of the objective lens while recording images in Gaussian focus. Images recorded with the Hilbert phase plate provide optimized positive phase contrast at low spatial frequencies, and the contrast transfer in principle extends to the information limit of the microscope. The antisymmetric Hilbert phase contrast (HPC) can be numerically converted into isotropic contrast, which is equivalent to the contrast obtained by a Zernike phase plate. Thus, in-focus HPC provides optimal structure factor information without limiting effects of the transfer function. In this article, we present the first electron tomograms of biological specimens reconstructed from Hilbert phase plate image series. We outline the technical implementation of the phase plate and demonstrate that the technique is routinely applicable for tomography. A comparison between conventional defocus tomograms and in-focus HPC volumes shows an enhanced SNR and an improved specimen visibility for in-focus Hilbert tomography.

  1. Comparison of detector materials for time-of-flight positron tomography

    International Nuclear Information System (INIS)

    Derenzo, S.E.

    1982-06-01

    Knowledge of detection efficiency and timing resolution is essential when comparing detector materials for time-of-flight positron tomography. We present results of Monte Carlo calculations of the detection efficiency of plastic, lead loaded plastic, NaI(T1), liquid xenon, bismuth germanate (BGO), CsF, BaF 2 , Ge, and HgI 2 for 511 keV photons. We also use recently published values of timing resolution for these detector materials to tabulate the quantity (efficiency) 2 /(time resolution) which is a measure of the relative sensitivity for time of flight positron tomography

  2. Toward regional-scale adjoint tomography in the deep earth

    Science.gov (United States)

    Masson, Y.; Romanowicz, B. A.

    2013-12-01

    Thanks to the development of efficient numerical computation methods, such as the Spectral Element Method (SEM) and to the increasing power of computer clusters, it is now possible to obtain regional-scale images of the Earth's interior using adjoint-tomography (e.g. Tape, C., et al., 2009). As for now, these tomographic models are limited to the upper layers of the earth, i.e., they provide us with high-resolution images of the crust and the upper part of the mantle. Given the gigantic amount of calculation it represents, obtaing similar models at the global scale (i.e. images of the entire Earth) seems out of reach at the moment. Furthermore, it's likely that the first generation of such global adjoint tomographic models will have a resolution significantly smaller than the current regional models. In order to image regions of interests in the deep Earth, such as plumes, slabs or large low shear velocity provinces (LLSVPs), while keeping the computation tractable, we are developing new tools that will allow us to perform regional-scale adjoint-tomography at arbitrary depths. In a recent study (Masson et al., 2013), we showed that a numerical equivalent of the time reversal mirrors used in experimental acoustics permits to confine the wave propagation computations (i.e. using SEM simulations) inside the region to be imaged. With this ability to limit wave propagation modeling inside a region of interest, obtaining the adjoint sensitivity kernels needed for tomographic imaging is only two steps further. First, the local wavefield modeling needs to be coupled with field extrapolation techniques in order to obtain synthetic seismograms at the surface of the earth. These seismograms will account for the 3D structure inside the region of interest in a quasi-exact manner. We will present preliminary results where the field-extrapolation is performed using Green's function computed in a 1D Earth model thanks to the Direct Solution Method (DSM). Once synthetic seismograms

  3. Positron emission tomography with gamma camera in coincidence mode

    International Nuclear Information System (INIS)

    Hertel, A.; Hoer, G.

    1999-01-01

    Positron emission tomography using F-18 FDG has been estbalished in clinical diagnostics with first indications especially in oncology. To install a conventional PET tomography (dedicated PET) is financially costly and restricted to PET examinations only. Increasing demand for PET diagnostics on one hand and restricted financial resources in the health system on the other hand led industry to develop SPECT cameras to be operated in coincidence mode (camera PET) in order to offer nuclear medicine physicians cost-effective devices for PET diagnostic. At the same time camera PET is inferior to conventional PET regarding sensitivity and detection-efficiency for 511 keV photons. Does camera-PET offer a reliable alternative to conventional PET? The first larger comparative studies are now available, so a first apraisal about the technical clinical performance of camera-PET can be done. (orig.) [de

  4. Technical realisation of the VISA-3 project, Parts I-II, Part II

    International Nuclear Information System (INIS)

    Pavicevic, M.; Smokovic, Z.

    1966-11-01

    This task is related to irradiation of reactor materials (steel, Al, MgO, Al 2 O 3 , ets.) at higher temperatures (200-500 deg C) in the fast neutron flux. This volume contains includes design specification and detailed engineering drawings of VISA-3 capsules, electric heaters, and all the devices needed for completing the task

  5. Correlative single photon emission computed tomography imaging of [123I]altropane binding in the rat model of Parkinson's

    International Nuclear Information System (INIS)

    Gleave, Jacqueline A.; Farncombe, Troy H.; Saab, Chantal; Doering, Laurie C.

    2011-01-01

    Introduction: This study used the dopamine transporter (DAT) probe, [ 123 I]-2β-carbomethoxy-3β-(4-fluorophenyl)-N-(3-iodo-E-allyl)nortropane ([ 123 I]altropane), to assess the DAT levels in the 6-hydroxydopamine rat model of Parkinson's disease. We sought to assess if the right to left [ 123 I]altropane striatal ratios correlated with dopamine content in the striatum and substantia nigra and with behavioural outcomes. Methods: [ 123 I]altropane images taken pre- and postlesion were acquired before and after the transplantation of neural stem/progenitor cells. The images obtained using [ 123 I]altropane and single photon emission computed tomography (SPECT) were compared with specific behavioural tests and the dopamine content assessed by high-performance liquid chromatography. Results: [ 123 I]altropane binding correlated with the content of dopamine in the striatum; however, [ 123 I]altropane binding did not correlate with the dopamine content in the substantia nigra. There was a significant correlation of altropane ratios with the cylinder test and the postural instability test, but not with amphetamine rotations. The low coefficient of determination (r 2 ) for these correlations indicated that [ 123 I]altropane SPECT was not a good predictor of behavioural outcomes. Conclusion: Our data reveal that [ 123 I]altropane predicts the integrity of the striatal dopamine nerve terminals, but does not predict the integrity of the nigrostriatal system. [ 123 I]altropane could be a useful marker to measure dopamine content in cell replacement therapies; however, it would not be able to evaluate outcomes for neuroprotective strategies.

  6. Computed tomography in multiple trauma patients. Technical aspects, work flow, and dose reduction

    International Nuclear Information System (INIS)

    Fellner, F.A.; Krieger, J.; Floery, D.; Lechner, N.

    2014-01-01

    Patients with severe, life-threatening trauma require a fast and accurate clinical and imaging diagnostic workup during the first phase of trauma management. Early whole-body computed tomography has clearly been proven to be the current standard of care of these patients. A similar imaging quality can be achieved in the multiple trauma setting compared with routine imaging especially using rapid, latest generation computed tomography (CT) scanners. This article encompasses a detailed view on the use of CT in patients with life-threatening trauma. A special focus is placed on radiological procedures in trauma units and on the methods for CT workup in routine cases and in challenging situations. Another focus discusses the potential of dose reduction of CT scans in multiple trauma as well as the examination of children with severe trauma. Various studies have demonstrated that early whole-body CT positively correlates with low morbidity and mortality and is clearly superior to the use of other imaging modalities. Optimal trauma unit management means a close cooperation between trauma surgeons, anesthesiologists and radiologists, whereby the radiologist is responsible for a rapid and accurate radiological workup and the rapid communication of imaging findings. However, even in the trauma setting, aspects of patient radiation doses should be kept in mind. (orig.) [de

  7. SU-E-I-12: Flexible Geometry Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, R [East Lansing, MI (United States)

    2015-06-15

    Purpose: The concept separates the mechanical connection between the radiation source and detector. This design allows the trajectory and orientation of the radiation source/detector to be customized to the object that is being imaged. This is in contrast to the formulaic rotation-translation image acquisition of conventional computed tomography(CT).Background/significance:CT devices that image a full range of: anatomy, patient populations, and imaging procedures are large. The root cause of the expanding size of comprehensive CT is due to the commitment to helical geometry that is hardwired into the image reconstruction. FGCT extends the application of alternative reconstruction techniques, i.e. tomosynthesis, by separating the two main components— radiation source and detector— and allow for 6 degrees of freedom motion for radiation source, detector, or both. The image acquisition geometry is then tailored to how the patient/object is positioned. This provides greater flexibility on the position and location that the patient/object is being imaged. Additionally, removing the need of a rotating gantry reduces the footprint so that CT is more mobile and more available to move to where the patient/object is at, instead of the other way around. Methods: As proof-of-principle, a reconstruction algorithm is designed to produce FGCT images. Using simulated detector data, voxels intersecting a line drawn between the radiation source and an individual detector are traced and modified using the detector signal. The detector signal is modified to compensate for changes in the source to detector distance. Adjacent voxels are modified in proportion to the detector signal, providing a simple image filter. Results: Image-quality from the proposed FGCT reconstruction technique is proving to be a challenge, producing hardily recognizable images from limited projections angles. Conclusion: Preliminary assessment of the reconstruction technique demonstrates the inevitable

  8. 2 CFR 182.125 - Does this part affect the Federal contracts that I receive?

    Science.gov (United States)

    2010-01-01

    ... GOVERNMENTWIDE GUIDANCE FOR GRANTS AND AGREEMENTS Reserved GOVERNMENTWIDE REQUIREMENTS FOR DRUG-FREE WORKPLACE (FINANCIAL ASSISTANCE) Purpose and Coverage § 182.125 Does this part affect the Federal contracts that I... violation of the requirements of this part, as described in § 182.510(c). However, this part does not apply...

  9. Bayesian inference for psychology. Part I : Theoretical advantages and practical ramifications

    NARCIS (Netherlands)

    Wagenmakers, E.-J.; Marsman, M.; Jamil, T.; Ly, A.; Verhagen, J.; Love, J.; Selker, R.; Gronau, Q.F.; Šmíra, M.; Epskamp, S.; Matzke, D.; Rouder, J.N.; Morey, R.D.

    2018-01-01

    Bayesian parameter estimation and Bayesian hypothesis testing present attractive alternatives to classical inference using confidence intervals and p values. In part I of this series we outline ten prominent advantages of the Bayesian approach. Many of these advantages translate to concrete

  10. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  11. Highly resolving computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions.

  12. Computer Tutors: An Innovative Approach to Computer Literacy. Part I: The Early Stages.

    Science.gov (United States)

    Targ, Joan

    1981-01-01

    In Part I of this two-part article, the author describes the evolution of the Computer Tutor project in Palo Alto, California, and the strategies she incorporated into a successful student-taught computer literacy program. Journal availability: Educational Computer, P.O. Box 535, Cupertino, CA 95015. (Editor/SJL)

  13. Indications for computed tomography (CT- diagnostics in proximal humeral fractures: a comparative study of plain radiography and computed tomography

    Directory of Open Access Journals (Sweden)

    Weise Kuno

    2009-04-01

    Full Text Available Abstract Background Precise indications for computed tomography (CT in proximal humeral fractures are not established. The purpose of this study was a comparison of conventional radiographic views with different CT reconstructions with 2 D and 3 D imaging to establish indications for additional CT diagnostics depending on the fractured parts. Methods In a prospective diagnostic study in two level 1 trauma centers, 44 patients with proximal humeral fractures were diagnosed with conventional X-rays (22 AP + axillary views, 22 AP + scapular Y-views and CT (multi-planar reconstruction (MPR and maximum intensity projection (MIP with 2 D and 3 D imaging. 3 observers assessed the technical image quality, the assessment of the relevant anatomical structures (2-sample-t-test and the percentage of the osseous overlap of the proximal humerus (Welch-test using a scoring system. The quality of the different diagnostic methods was assessed according to the number of fractured parts (Bonferroni-Holm adjustment. Results There was significantly more overlap of the fractured region on the scapular Y-views (mean 71.5%, range 45–90% than on axillary views (mean 56.2%, range 10.5–100%. CT-diagnostics allowed a significantly better assessment of the relevant structures than conventional diagnostics (p Conclusion Conventional X-rays with AP view and a high-quality axillary view are useful for primary diagnostics of the fracture and often but not always show a clear presentation of the relevant bony structures such as both tuberosities, the glenoid and humeral head. CT with thin slices technology and additional 3 D imaging provides always a clear presentation of the fractured region. Clinically, a CT should be performed – independently of the number of fractured parts – when the proximal humerus and the shoulder joint are not presented with sufficient X-ray-quality to establish a treatment plan.

  14. Cerebral metabolic data obtained by positron emission tomography in physiological aging. A review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Pellat, J; Hommel, M

    1987-06-18

    Following a summary of the general principles and limitations of metabolic measurements by positron emission tomography and of the different indices used to interpret the data, the authors review the results of published studies on physiological aging. Globally, with strict inclusion criteria absolute metabolic values at rest and under partial sensorial deprivation are little or not modified by age. In contrast, functional interactions between regions, as deduced from metabolic intercorrelations, are perhaps different in elderly people. In any case, positron emission tomography seems to discriminate between normal aging and different patterns of pathological aging. Technical improvements, more refined neuropsychological correlations and the use of dynamic activation paradigms will no doubt provide, in the future, a better definition of normal and pathological aging as positron tomography.

  15. Cerebral metabolic data obtained by positron emission tomography in physiological aging. A review of the literature

    International Nuclear Information System (INIS)

    Pellat, J.; Hommel, M.

    1987-01-01

    Following a summary of the general principles and limitations of metabolic measurements by positron emission tomography and of the different indices used to interpret the data, the authors review the results of published studies on physiological aging. Globally, with strict inclusion criteria absolute metabolic values at rest and under partial sensorial deprivation are little or not modified by age. In contrast, functional interactions between regions, as deduced from metabolic intercorrelations, are perhaps different in elderly people. In any case, positron emission tomography seems to discriminate between normal aging and different patterns of pathological aging. Technical improvements, more refined neuropsychological correlations and the use of dynamic activation paradigms will no doubt provide, in the future, a better definition of normal and pathological aging as positron tomography [fr

  16. 28 CFR Appendix I to Part 16 - Components of the Department of Justice

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Components of the Department of Justice I Appendix I to Part 16 Judicial Administration DEPARTMENT OF JUSTICE PRODUCTION OR DISCLOSURE OF MATERIAL OR... Enforcement Administration, U.S. Department of Justice, Washington, DC 20537-0001 Executive Office for...

  17. Technical-tactical analysis of youth olympic taekwondo combat.

    Science.gov (United States)

    Tornello, Francesco; Capranica, Laura; Minganti, Carlo; Chiodo, Salvatore; Condello, Giancarlo; Tessitore, Antonio

    2014-04-01

    The purpose of this study was to define the technical and tactical profiles of official youth taekwondo competitions played under the most recent rules of the International Taekwondo Federation. Tactical actions (i.e., attack, defense, and block), technical executions (from 1- to 4-point scores), kicking legs (i.e., front/rear and right/left), and overall technical effectiveness were investigated in relation to match outcome of semifinal and final competitions (n = 50) of youth (aged 13-14 years) black belt athletes during the Italian Taekwondo Cadet Championship. Differences (p technical exchanges showed differences (p technical executions. Winners resulted more efficient (p technical and tactical variables. In general, these findings showed that Cadets tend to adopt an offensive strategy. In considering that the adoption of the new electronic system requires athletes to execute correct technical actions to have a score assigned, coaches should emphasize the effectiveness of scoring techniques and help athletes to effectively improve their defense and counterattack capabilities.

  18. The technical writer's handbook writing with style and clarity

    CERN Document Server

    Young, Matt

    2002-01-01

    "The Technical Writer's Handbook" is by a practising scientist who screens hundreds of manuscripts each year. It is directed at scientists, engineers and others who want to improve their writing and communication. It teaches that technical writing, although it has its own special requirements, is no different from ordinary writing and should be written with short, clear sentences and in the active voice. Divided into two parts, the first part is an introduction to technical and report writing and provides a sort of prescription for writing and organizing technical papers of all kinds. The second part is written in dictionary format and contains entries on grammar, style, and organization, as well as entries on topics such as common errors, resume writing, metric units, jargon, conference proceedings, figures, tables and slides. A comprehensive list of cross-references reveals related topics quickly and easily.

  19. Technological Evolution on Computed Tomography and Radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Bruno Barros; Ribeiro, Nuno Carrilho [Servico de Radiologia, Hospital de Curry Cabral, Rua da Beneficencia, 8, 1069-166 Lisboa (Portugal)

    2006-05-15

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  20. Technological Evolution on Computed Tomography and Radioprotection

    International Nuclear Information System (INIS)

    Leite, Bruno Barros; Ribeiro, Nuno Carrilho

    2006-01-01

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  1. Review of cardiovascular imaging in the journal of nuclear cardiology in 2015. Part 1 of 2: Plaque imaging, positron emission tomography, computed tomography, and magnetic resonance.

    Science.gov (United States)

    AlJaroudi, Wael A; Hage, Fadi G

    2016-02-01

    In 2015, many original articles pertaining to cardiovascular imaging with impressive quality were published in the Journal of Nuclear Cardiology. In a set of 2 articles, we provide an overview of these contributions to facilitate for the interested reader a quick review of the advancements that occurred in the field over this year. In this first article, we focus on arterial plaque imaging, cardiac positron emission tomography, computed tomography, and magnetic resonance imaging.

  2. Monoamine oxidase B single-photon emission tomography with [123I]Ro 43-0463: imaging in volunteers and patients with temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Buck, A.; Frey, L.D.; Blaeuenstein, P.; Schubiger, P.; Kraemer, G.; Siegel, A.; Weber, B.; Wieser, H.G.

    1998-01-01

    Imaging of monoamine oxidase of subtype B (MAO B) is of interest in various neurological diseases. In the past non-invasive assessment of MAO B has only been possible with positron emission tomography (PET) ligands. Given the limited availability of PET, a single-photon emission tomography (SPET) ligand would be desirable. In this study SPET imaging with the new MAO B inhibitor [ 123 I]Ro 43-0463 was performed in five volunteers and nine patients with temporal lobe epilepsy (TLE). In two volunteers a second study was performed 12 h following blockade with deprenyl. In the TLE patients the tracer was administered as bolus (n = 4) or as prolonged infusion (n = 5). The regional uptake pattern correlated well with the known distribution of MAO B. In the two blocking studies ligand uptake was substantially reduced compared with baseline. In the TLE patients increased uptake was found in the ipsilateral mesial temporal lobe and, surprisingly, in the ipsilateral putamen. This study indicates the potential of the new SPET ligand [ 123 I]Ro 43-0463 to map MAO B concentration in the human brain. The new finding of increased MAO B in the putamen of TLE patients needs further studies to elucidate its exact pathophysiology. (orig.)

  3. Technical Training: Technical Training Seminar

    CERN Multimedia

    2004-01-01

    TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch Tuesday 3 February 2004 From 09:00 to 13:30 - Training Centre Auditorium - bldg. 593, room 11 USB (Universal Serial Bus) CYPRESS Seminar Claudia Colombini, Field Application Engineer CYPRESS ActiveComp Electronic GmbH D-85077 MANCHING, Germany As a pioneer in USB, CYPRESS sets the standard for cost-effective solutions without sacrificing functionality, performance or reliability. Having shipped over 200 million USB devices, Cypress is the undisputed market leader and demonstrates unmatched USB expertise. With the industry's broadest selection of USB solutions, Cypress has the right silicon, software and support for every USB application, from Low-speed to High-Speed and USB On-The-Go (OTG). 9:00 - 10:30 Overview of USB systems. USB CYPRESS product overview. Peripherals: Low Speed, Full Speed, High Speed (1.1 and 2.0). Hub Solutions, Embedded Host Solutions, On-The-Go (OTG) and wireless USB. USB Development Tools (first part) 10:30 -...

  4. Intracoronary Optical Coherence Tomography: A Comprehensive Review: Clinical and Research Applications

    OpenAIRE

    Bezerra, Hiram G.; Costa, Marco A.; Guagliumi, Giulio; Rollins, Andrew M.; Simon, Daniel I.

    2009-01-01

    Cardiovascular optical coherence tomography (OCT) is a catheter-based invasive imaging system. Using light rather than ultrasound, OCT produces high-resolution in vivo images of coronary arteries and deployed stents. This comprehensive review will assist practicing interventional cardiologists in understanding the technical aspects of OCT based upon the physics of light and will also highlight the emerging research and clinical applications of OCT. Semi-automated imaging analyses of OCT syste...

  5. Super-sensing technology: industrial applications and future challenges of electrical tomography.

    Science.gov (United States)

    Wei, Kent Hsin-Yu; Qiu, Chang-Hua; Primrose, Ken

    2016-06-28

    Electrical tomography is a relatively new imaging technique that can image the distribution of the passive electrical properties of an object. Since electrical tomography technology was proposed in the 1980s, the technique has evolved rapidly because of its low cost, easy scale-up and non-invasive features. The technique itself can be sensitive to all passive electrical properties, such as conductivity, permittivity and permeability. Hence, it has a huge potential to be applied in many applications. Owing to its ill-posed nature and low image resolution, electrical tomography attracts more attention in industrial fields than biomedical fields. In the past decades, there have been many research developments and industrial implementations of electrical tomography; nevertheless, the awareness of this technology in industrial sectors is still one of the biggest limitations for technology implementation. In this paper, the authors have summarized several representative applications that use electrical tomography. Some of the current tomography research activities will also be discussed. This article is part of the themed issue 'Supersensing through industrial process tomography'. © 2016 The Author(s).

  6. Engineering Technical Support Center Annual Report Fiscal Year 2015

    Science.gov (United States)

    The United States Environmental Protection Agency (EPA or Agency) Office of Research and Development (ORD) created the Engineering Technical Support Center (ETSC) in 1987, one of several technical support centers created as part of the Technical Support Project (TSP). ETSC provid...

  7. Tenth annual meeting, Vienna, Austria, 29 March - 1 April 1977. Summary report. Part I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-05-01

    The Summary Report of Tenth Annual Meeting of the IAEA International Working Group on Fast Reactors contains the Minutes of the Meeting (Part I); the papers which review the national programmes in the field of LMFBRs and other presentations at the Meeting (Part II); and the discussions on the review of the national programmes (Part III)

  8. Regional cerebral blood flow measured with N-isopropyl-p-[123I]iodoamphetamine single-photon emission tomography in patients with Joseph disease

    International Nuclear Information System (INIS)

    Takahashi, Naoya; Odano, Ikuo; Nishihara, Mamiko; Yuasa, Tatsuhiko; Sakai, Kunio

    1994-01-01

    Regional cerebral blood flow (rCBF) was measured in five Japanese patients who were clinically diagnosed as having Joseph disease, also called Machado-Joseph disease or Azorean disease, using N-isopropyl-p-[ 123 I]iodoamphetamine (IMP) and single-photon emission tomography (SPET). Cerebellar atrophy was evaluated by a five-step rating scale as defined on X-ray computed tomography (X-CT). Compared with ten age-matched normal controls (mean cerebellar CBF ± SD: 66.9 ± 6.6 ml/100 g/min), rCBF in patients with Joseph disease was significantly decreased in the cerebellum (mean ± SD: 50.2 ± 7.3 ml/100 g/min). No significant relationship, however, was found between the decrease in rCBF in the cerebellum and the degree of cerebellar atrophy on X-CT. rCBF in the cerebellum was minimally decreased in one patient who had severe cerebellar atrophy and in two patients with moderate atrophy. These data may support the findings that Purkinje cells in the cerebellum are almost normal in Joseph disease, and that the granular and molecular layers remain intact in spite of cortical atrophy of the cerebellum. It is concluded that [ 123 I]-IMP SPET is able to identify pathological and metabolic changes in the cerebellum that do not appear on X-CT or magnetic resonance imaging, and thus is useful for the diagnosis of Joseph disease. (orig.)

  9. Nonceramic insulators for the transmission power lines. Part I: Experiences of a promising technology; Aisladores no ceramicos para las lineas de transmision. Parte I: Experiencias de una tecnologia prometedora

    Energy Technology Data Exchange (ETDEWEB)

    Fierro Chavez, Jose Luis [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    The nonceramic insulators have special characteristics that make them attractive to solve problems detected in glass or porcelain insulators, mainly in zones of high contamination and vandalism. In this first part a panorama is presented of the operative experience with nonceramic insulators for transmission power lines in different parts of the world until the beginning of the Nineties decade. The tendency in its use has increased remarkably in new transmission projects, mainly in the United States, but the operative experience shows that the selection of such insulators requires a careful analysis and of a pursuit of its behavior in the field that allows the establishments of its technical - economic advantages or disadvantages of its long term application. [Spanish] Los aisladores no ceramicos poseen caracteristicas especiales que los hacen atractivos para resolver problemas detectados en los aisladores de vidrio o porcelana, principalmente en zonas de alta contaminacion y vandalismo. En esta primera parte se presenta un panorama de la experiencia operativa con aisladores no ceramicos para las lineas de transmision en diferentes partes del mundo hasta principios de la decada de los noventa. La tendencia en su uso ha incrementado notablemente en nuevos proyectos de transmision, principalmente en los Estados Unidos, pero la experiencia operativa muestra que la seleccion de dichos aisladores requiere de un analisis cuidadoso y de un seguimiento de su comportamiento en campo que permita establecer las ventajas o desventajas tecnico - economicas de su aplicacion a largo plazo.

  10. Appropriateness of computed tomography and magnetic resonance ...

    African Journals Online (AJOL)

    Introduction. Computed tomography (CT) and magnetic resonance imaging (MRI) are an essential part of modern healthcare. Marked increases in clinical demand for these imaging modalities are straining healthcare expenditure and threatening health system sustainability. The number of CT and MRI scans requested in ...

  11. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  12. Cone beam computed tomography in Endodontics - a review.

    Science.gov (United States)

    Patel, S; Durack, C; Abella, F; Shemesh, H; Roig, M; Lemberg, K

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on the applications and limitations of CBCT; (ii) make recommendations for the use of CBCT in Endodontics; (iii) highlight areas of further research of CBCT in Endodontics. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  13. International Working Group on Fast Reactors Thirteenth Annual Meeting. Summary Report. Part I

    International Nuclear Information System (INIS)

    1980-09-01

    The Thirteenth Annual Meeting of the IAEA International Working Group on Fast Reactors was held at the IAEA Headquarters, Vienna, Austria from 9 to 11 April 1980. The Summary Report (Part I) contains the Minutes of the Meeting. The Summary Report (Part II) contains the papers which review the national programme in the field of LMFBRs and other presentations at the Meeting. The Summary Report (Part III) contains the discussions on the review of the national programmes

  14. Strategic Planning: A Practical Primer for the Healthcare Provider: Part I.

    Science.gov (United States)

    Baum, Neil; Brockmann, Erich N; Lacho, Kenneth J

    2016-01-01

    Entrepreneurs are known for opportunity recognition--that is, "How can I start a business to make money from this opportunity?" However, once a commercial entity is formed to take advantage of an opportunity, the leadership priority shifts from entrepreneurial to strategic. A strategic perspective leverages limited resources to position a business for future success relative to rivals in a competitive environment. Often, the talents needed for one priority are not the same as those needed for the other. This article, the first part of a two-part article, intends to simplify the transition from an entrepreneurial to a strategic focus. It walks an entrepreneur through the strategic management planning process using a fictional business. The various tasks in the process (i.e., mission, vision, internal analysis, external analysis) are illustrated with examples from a typical primary physician's private practice. The examples show how the strategic management tasks are interrelated and ultimately lead to a philosophical approach to managing a business.

  15. Density evaluation by computerized tomography in plain soils over different manipulation systems; Avaliacao da densidade pelo metodo da tomografia computadorizada de um planossolo sob diferentes sistemas de manejo

    Energy Technology Data Exchange (ETDEWEB)

    Pedrotti, Alceu [Lavras Univ., MG (Brazil). Dept. de Ciencia do Solo; Pauletto, Eloy Antonio [Pelotas Univ., RS (Brazil). Dept. de Solos; Crestana, Silvio [Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA), Sao Carlos, SP (Brazil). Centro Nacional de Pesquisa e Desenvolvimento de Instrumentacao Agropecuaria (CNPDIA)

    1996-08-01

    The objective of this paper is the evaluation of a plain soil density in different culture systems determined by X ray computerized tomography.It was observed a larger variation in densities in soils profiles analysed. The identification of layers is better utilising computerized tomography than others technic 1 fig.

  16. Music in the exercise domain: a review and synthesis (Part I).

    Science.gov (United States)

    Karageorghis, Costas I; Priest, David-Lee

    2012-03-01

    Since a 1997 review by Karageorghis and Terry, which highlighted the state of knowledge and methodological weaknesses, the number of studies investigating musical reactivity in relation to exercise has swelled considerably. In this two-part review paper, the development of conceptual approaches and mechanisms underlying the effects of music are explicated (Part I), followed by a critical review and synthesis of empirical work (spread over Parts I and II). Pre-task music has been shown to optimise arousal, facilitate task-relevant imagery and improve performance in simple motoric tasks. During repetitive, endurance-type activities, self-selected, motivational and stimulative music has been shown to enhance affect, reduce ratings of perceived exertion, improve energy efficiency and lead to increased work output. There is evidence to suggest that carefully selected music can promote ergogenic and psychological benefits during high-intensity exercise, although it appears to be ineffective in reducing perceptions of exertion beyond the anaerobic threshold. The effects of music appear to be at their most potent when it is used to accompany self-paced exercise or in externally valid conditions. When selected according to its motivational qualities, the positive impact of music on both psychological state and performance is magnified. Guidelines are provided for future research and exercise practitioners.

  17. Technical co-operation report for 2000. Report by the Director General

    International Nuclear Information System (INIS)

    2001-01-01

    This report covers three separate topics. Part one fulfills the Agency's obligation under the General Conference resolution GC(44)/RES/18 to report on the Strengthening of Technical Co-operation. It covers the period from 1 April 2000 to 31 March 2001. The report examines the finalization of the 2001-2002 technical co-operation programme and several key concepts of the Technical Co-operation Strategy such as Partners in Development, Technical Co-operation among Developing Countries, and the continuing evolution of Regional Resource Centres. Reflecting an important trend in the technical co-operation programme, which was mandated by the General Conference, the report describes the results achieved in several programmes in least developed countries. Part two reports on the major achievements of the technical co-operation programme in 2000 in the different regions of the world. Part three presents a summary of the financial and non-financial parameters of the technical co-operation programme. The supplement to the report provides a more detailed review of resources and contributions, disbursements and non-financial indicators

  18. Technical co-operation report for 2000. Report by the Director General

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This report covers three separate topics. Part one fulfills the Agency's obligation under the General Conference resolution GC(44)/RES/18 to report on the Strengthening of Technical Co-operation. It covers the period from 1 April 2000 to 31 March 2001. The report examines the finalization of the 2001-2002 technical co-operation programme and several key concepts of the Technical Co-operation Strategy such as Partners in Development, Technical Co-operation among Developing Countries, and the continuing evolution of Regional Resource Centres. Reflecting an important trend in the technical co-operation programme, which was mandated by the General Conference, the report describes the results achieved in several programmes in least developed countries. Part two reports on the major achievements of the technical co-operation programme in 2000 in the different regions of the world. Part three presents a summary of the financial and non-financial parameters of the technical co-operation programme. The supplement to the report provides a more detailed review of resources and contributions, disbursements and non-financial indicators.

  19. Catalogue of the Coreidae in the Rijksmuseum van Natuurlijke Historie : Part I. Corizinae, Alydinae

    NARCIS (Netherlands)

    Blöte, H.C.

    1934-01-01

    As a result of my further work on the reordening of the collection of bugs in the Leiden Museum I am giving now a catalogue of the Coreidae in the Museum, which will appear in some parts, as the group is rather large. Again I was enabled to visit the British Museum (Natural History), and I will

  20. Geologic literature on North America, 1785-1918; Part I, Bibliography

    Science.gov (United States)

    Nickles, John M.

    1923-01-01

    The bibliography forming Part I of this compilation includes papers relating to the geology paleontology, petrology, and mineralogy of North America-specifically, the United States, the Dominion of Canada and Newfoundland, the Arctic regions north of the continent, Greenland, Mexico Central America, Panama, and the West Indies including Trinidad-and also the Hawaiian Islands. Geographic and descriptive writings and accounts of travels with incidental mention of geologic facts are not included. Textbooks published in America and work general in character by American authors are given but general papers by foreign writers are excluded unless they have appeared in American publications. Papers by American writers on the geology of other parts of the world are not listed.

  1. Positron emission tomography and migraine

    International Nuclear Information System (INIS)

    Chabriat, H.

    1992-01-01

    Positron emission tomography (PET) is a brain imaging technique that allows in vivo studies of numerous physiological parameters. There have been few PET studies in migraine patients. Cerebral blood flow changes with no variations in brain oxygen consumption have been reported in patients with prolonged neurologic manifestations during migraine attacks. Parenteral administration of reserpine during migraine headache has been followed by a fall in the overall cerebral uptake of glucose. The small sample sizes and a number of methodologic problems complicate the interpretation of these results. Recent technical advances and the development of new PET tracers can be expected to provide further insight into the pathophysiology of migraine. Today cerebral cortex 5 HT 2 serotonin receptors can be studied in migraine patients with PET

  2. Evaluation of thyroid nodules by 123I thyroid scintigraphy and computed tomography

    International Nuclear Information System (INIS)

    Kurihara, Yoshiko; Imanishi, Yoshimasa; Ehara, Norishige

    1991-01-01

    We have already reported that computed tomography (CT) could be used to quantify iodine concentration in the thyroid. Correlation between CT value and iodine concentration in thyroid tissues was represented by the following formula (n=31, r=0.96): iodine concentration=(CT value-65)/104 (mg/g). In this study, we evaluated thyroid nodules by 123 I thyroid scintigraphy and histograms of CT values in the nodules. Radioiodine accumulation and the histograms on CT of the thyroid nodules were correlated with the histopathology of 35 thyroid nodules (22 benign nodules, 13 malignant nodules) of 27 patients. Results showed no definite correlation between radioiodine accumulation in the thyroid nodule and the pattern on CT reflecting iodine concentration in the nodule. Some nodules with little radioiodine accumulation had considerable iodine concentration. Benign thyroid nodules tended to have lower iodine concentration than malignant nodules. Fifteen (94%) of 16 nodules showing only minimal iodine concentration were benign. We conclude that the function and/or differentiation of tumor cells in the thyroid nodule must be evaluated not only radioiodine accumulation in the nodule but also by iodine concentration in the nodule and that thyroid nodules with only minimal iodine concentration are most likely benign. (author)

  3. Technical recommendations for bilateral comparison in diagnosis radiology: part 3

    International Nuclear Information System (INIS)

    Peixoto, J.G.P.; Almeida, C.E.V. de

    2015-01-01

    Uncertainty and results homogeneity need to following the technical procedure to bilateral comparison, then we select the equipment used, reference conditions and the data file to be used for all participant laboratory. The partial results will be presentation at metrology and medical physics congress. (author)

  4. Technical realization of the VISA-2 Project, contract: 2.01/ I phase, Volume No. I; Tehnicka realizacija projekta VISA-2, ugovor: 2.01/I faza, Album br. I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1963-12-15

    Cooperation between the Institutes in Vinca and Saclay has started by carrying out the task 'Technical realization of the VISA-2 project' which should enable: obtaining new experimental spaces in the RA reactor with high fast neutron flux for sample irradiation; obtaining experience in reactor continual operation for few months at nominal power of 6.5 MW and increase of RA reactor utilization; solving the problem of activated channels and samples transport, problems of working in hot cells; obtaining irradiated samples for examining radiation effects first in Saclay and later in Vinca. The project is divided in three phases. Phase one covers the reconstruction of the RA reactor fuel channels according to the VISA-2 project demands. The second phase includes the activities related to measuring devices for measuring the temperatures at the incoming and outgoing heavy water in 5 VISA-2 channels, as well as temperature of the samples (55 thermocouples) and testing the channels and capsules after their insertion in the reactor. The third phase includes activities are related to problems of transport of radioactive channels and VISA-2 capsules, problems of cutting as well as packing and transporting of irradiated samples from Vinca to Saclay. This volume includes all the relevant documents for completing the task including contracts, needed preliminary calculations as well as safety analysis. [Serbo-Croat] Saradnja izmedju Instituta u Vinci i Saclay-u zapoceta je realizacijom zadatka 'Tehnicka realizacije projekta VISA-2' koji treba da omoguci: dobijanje novih eksperimentalnih prostora u reaktoru RA sa visokom vrednoscu fluksa brzih neutrona za ozracivanje uzoraka; sticanje pogonskih iskustava u visemesecnom kontilualnom radu na nominalnoj snazi od 6,5 MW i povecanje stepena koriscenja reaktora RA; resenje pitanja transporta aktivnih kanala i uzoraka, problema rada u vrucim celijama; dobijanje ozracenih uzoraka za izucavanje, u prvo vreme u Saclay-u, a kasnije i u Vinci

  5. Patient radiation exposure in computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pavlov, V [Meditsinska Akademiya, Sofia (Bulgaria)

    1980-01-01

    Radiation exposure to patients undergoing axial computerized tomography as a tool of neurological X-ray diagnostics was studied. Doses thereby delivered were compared with those from routine head films at X-ray tube parameters 200 W, 70 kV, and 70 cm target-to-patient distance. Radiation exposures were analyzed with a view to improving shielding and procedural techniques. Comparisons were made using LiF TLD measurements with an Alderson phantom (standard for axial computer tomography). Skin and intracranial space doses were compared using two computers, Siretom I and Siretom 2000, for various positionings: frontal, fronto-lateral, temporal, temporo-occipital, and occipital. In addition, patient body doses with or without shielding and doses to subjects attending sick children or restless adults were examined. Achievable protection was estimated for lead shields of 0.5 mm lead equivalent. It was concluded that radiation doses delivered to neurologic patients undergoing axial computer tomography are smaller than those resulting from conventional X-ray examinations.

  6. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[{sup 123}I]iodoamphetamine ({sup 123}I-IMP) in schizophrenia and atypical psychosis

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Hidemichi; Hayashi, Takuji; Mitsugi, Ohara [Aichi Medical Univ., Nagakute (Japan)

    1994-12-01

    As a basis for possible classification of schinzophrenic psychoses into schizophrenia and atypical psychosis, we studied the brain functional differences among 16 schizophrenic patients, 16 atypical psychosis patients and 16 healthy volunteers by single photon emission computed tomography (SPECT) using N-isopropyl-p-[{sup 123}I] iodoamphetamine. As a result, schizophrenics showed hypofrontality. On the other hand, atypical psychotics had no such hypofrontality but showed a reduced uptake rate in the right thalamic region. No influence of sex, duration of illness and medication was confirmed by the findings. The results suggest that schizophrenics might have some lesions in the frontal regions, whereas atypical psychotics might have no such lesions, but dysfunction in the right thalamic region. Consequently, the SPECT findings as least indicate possibly different etiologies for schizophrenia and atypical psychosis. (author).

  7. Nursing as concrete philosophy, Part I: Risjord on nursing knowledge.

    Science.gov (United States)

    Theodoridis, Kyriakos

    2018-04-01

    This essay addresses the problem of the essentiality of nursing knowledge and what kind of theory, if any, is essential to nursing practice. The overarching aim of the essay was to argue for the thesis that nursing may be described as a kind of philosophical activity, and, consequently, that philosophy is the kind of "theory" that is essential to nursing practice and to the nursing discipline at large. The essay consists of two papers. The present paper, Part I, is a critical examination of Mark Risjord's discussion of the problem of the theory-practice gap in his Nursing Knowledge: Practice, Science, Philosophy, from 2010. According to Risjord, the cause of the theory-practice gap originates in an erroneous conception of science (logical positivism) which had a decisive influence upon the way nursing scholars appropriated theoretical frameworks for the nursing discipline. This philosophical influence is considered in effect to have generated the theory-practice gap. In order to bridge the gap, Risjord suggests, the nursing discipline needs to adopt a standpoint epistemology conjoined with a postpositivist conception of scientific theory. In this way, a legitimate brand of nursing science may be developed and the theory-practice gap overcome. I will argue that neither Risjord's diagnosis of the problem, nor his recommended cure, may succeed in rescuing the nursing discipline from the theory-practice gap. Rather, the real cause of the theory-practice gap, I will claim, derives from an erroneous conception of nursing (not of science), namely the conception of nursing as a kind of science (roughly speaking). On my view, to overcome the gap, the nursing discipline needs to make salient the inherently philosophical character of nursing. In the second paper (Part II), I will continue the discussion of nursing knowledge and delineate the thesis of nursing as a kind of concrete philosophy. © 2017 John Wiley & Sons Ltd.

  8. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  9. History and challenges of barium titanate: Part I

    Directory of Open Access Journals (Sweden)

    Vijatović M.M.

    2008-01-01

    Full Text Available Barium titanate is the first ferroelectric ceramics and a good candidate for a variety of applications due to its excellent dielectric, ferroelectric and piezoelectric properties. Barium titanate is a member of a large family of compounds with the general formula ABO3 called perovskites. Barium titanate can be prepared using different methods. The synthesis method depends on the desired characteristics for the end application. The used method has a significant influence on the structure and properties of barium titanate materials. In this review paper, Part I contains a study of the BaTiO3 structure and frequently used synthesis methods.

  10. Evaluation of diffuse thyroid diseases by computed tomography and 123I thyroidal uptake

    International Nuclear Information System (INIS)

    Kurihara, Yoshiko; Imanishi, Yoshimasa; Ehara, Norishige

    1991-01-01

    Understanding the iodine kinetics in the thyroid is useful for the diagnosis of a patient with diffuse thyroid disease. In this study, 9 controls and 50 patients with diffuse thyroid diseases, we evaluated diffuse thyroid diseases with 123 I thyroidal uptake and volume, iodine concentration, and net iodine content measured by computed tomography. There was no significant correlation between volume, iodine concentration, and net iodine content of the thyroid and 123 I thyroidal uptake. The thyroid volume in Graves' and Hashimoto's diseases was significantly larger than that in the control group. The thyroid iodine concentration in Graves' and Hashimoto's diseases was significantly smaller than that in the control group. The thyroid net iodine content in Hashimoto's disease was significantly smaller than that in the control group. Although most of the patients with Graves' disease had more increased radioiodine thyroidal uptake than the control group, there was no significant difference between them in the mean of the thyroid net iodine content. But the variance of net iodine contents in the former was significantly larger than that in the latter. The thyroid net iodine content was very low in all patients with very high thyroglobulin hemaggrugated antibody (TGHA) value although it was nearly normal in some patients with normal TGHA value. It was suggested that iodine concentration and net iodine content might be determined not only by iodine uptake but also by release and/or leakage of iodine compounds from the thyroid, which might depend on some antithyroid antibodies. (author)

  11. Physical properties of root cementum: Part 26. Effects of micro-osteoperforations on orthodontic root resorption: A microcomputed tomography study.

    Science.gov (United States)

    Chan, Emmanuel; Dalci, Oyku; Petocz, Peter; Papadopoulou, Alexandra K; Darendeliler, M Ali

    2018-02-01

    Studies have demonstrated the potential efficacy of micro-osteoperforations in accelerating tooth movement by amplifying the expression of inflammatory markers. The aim of this investigation was to examine the effects of micro-osteoperforations on orthodontic root resorption with microcomputed tomography. This prospective controlled clinical trial involved 20 subjects requiring extraction of the maxillary first premolars as part of their orthodontic treatment. A buccal tipping force of 150 g was applied to both premolars. Using the Propel appliance (Propel Orthodontics, San Jose, Calif), micro-osteoperforations were applied at a depth of 5 mm on the mesial and distal aspects in the midroot region of the experimental side of the first premolar root; the contralateral side served as the control. After 28 days, both premolars were extracted. The teeth were scanned under microcomputed tomography, and the volumes of root resorption craters were calculated and compared. Premolars treated with micro-osteoperforation exhibited significantly greater average total amounts of root resorption than did the control teeth (0.576 vs 0.406 mm 3 ). The total average volumetric root loss of premolars treated with micro-osteoperforation was 42% greater than that of the control teeth. This 28-day trial showed that micro-osteoperforations resulted in greater orthodontic root resorption. However, these results should be verified in patients who are undergoing full-length orthodontic treatment. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  12. The Influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings - Part I: Theory

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Santos, Ilmar; Fuerst, Axel

    2007-01-01

    This is Part I of a two-part series of papers describing the effects of high-pressure injection pockets on the operating conditions of tilting-pad thrust bearings. In Part I a numerical model based on the Reynolds equation is developed extending the threedimensional thermoelastohydrodynamic (TEHD......) analysis of tilting-pad thrust bearings to include the effects of high-pressure injection and recesses in the bearing pads. The model is applied to the analysis of an existing bearing of large dimensions and the influence of the pocket is analyzed. In the analysis, the high-pressure oil injection used...... for hydrostatic jacking is turned off (i.e., only the effect of the pocket is studied). It is shown that a shallow pocket positively influences the performance of the bearing because it has characteristics similar to those of a Rayleigh-step bearing. In Part II of the paper (Heinrichson, N., Fuerst, A...

  13. Mission Plan for the Civilian Radioactive Waste Management Program. Volume I. Part I. Overview and current program plans; Part II. Information required by the Nuclear Waste Policy Act of 1982

    International Nuclear Information System (INIS)

    1985-06-01

    The Misson Plan is divided into two parts. Part I describes the overall goals, objectives, and strategy for the disposal of spent nuclear fuel and high-level waste. It explains that, to meet the directives of the Nuclear Waste Policy Act, the DOE intends to site, design, construct, and start operating a mined geologic repository by January 31, 1998. The Act specifies that the costs of these activities will be borne by the owners and generators of the waste received at the repository. Part I further describes the other components of the waste-management program - monitored retrievable storage, Federal interim storage, and transportation - as well as systems integration activities. Also discussed are institutional plans and activities as well as the program-management system being implemented by the Office of Civilian Radioactive Waste Management. Part II of the Mission Plan presents the detailed information required by Section 301(a) of the Act - key issues and information needs; plans for obtaining the necessary information; potential financial, institutional, and legal issues; plans for the test and evaluation facility; the principal results obtained to date from site investigations; information on the site-characterization programs; information on the waste package; schedules; costs; and socioeconomic impacts. In accordance with Section 301(a) of the Act, Part II is concerned primarily with the repository program

  14. Computed tomography of the carotid space and related cervical spaces. Part 1. Anatomy

    International Nuclear Information System (INIS)

    Silver, A.J.; Mawad, M.E.; Hilal, S.K.; Sane, P.; Ganti, S.R.

    1984-01-01

    The carotid space, parapharyngeal space, and paraspinal space are described. The carotid space is shown on computed tomography (CT) to be posterior to the parapharyngeal space and separated from it by the styloid apparatus. The paraspinal space is posterior to the carotid space and separated from it by the longus and anterior scalene muscles

  15. Figures and First Years: An Analysis of Calculus Students' Use of Figures in Technical Reports

    Directory of Open Access Journals (Sweden)

    Nathan J. Antonacci

    2017-07-01

    Full Text Available This three-year study focused on first-year Calculus I students and their abilities to incorporate figures in technical reports. In each year, these calculus students wrote a technical report as part of the Polar Bear Module, an educational unit developed for use in partner courses in biology, computer science, mathematics, and physics as part of the Multidisciplinary Sustainability Education (MSE project at Ithaca College. In the first year of the project, students received basic technical report guidelines. In year two, the report guidelines changed to include explicit language on how to incorporate figures. In year three, a grading rubric was added to the materials provided to one of the two classes. In all three years, the students performed below expectations in their use of graphs in their reports. Reviews of the figures in the 78 technical reports written by the 106 students showed repeated deficiencies in the figures and how the students used them in the discussion sections and in evidence-based arguments. In year three the student’s quantitative literacy (QL skills were assessed using an extract from a QL assessment instrument published in Numeracy. The results indicated that the students could both read and interpret figures, suggesting that issues with QL were not the main contributor to student difficulty with written discussion about graphs. The study underscores the need that explicit instructional attention be given to developing student knowhow in the use of figures in technical reports.

  16. Structure Learning and Statistical Estimation in Distribution Networks - Part I

    Energy Technology Data Exchange (ETDEWEB)

    Deka, Deepjyoti [Univ. of Texas, Austin, TX (United States); Backhaus, Scott N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chertkov, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-02-13

    Traditionally power distribution networks are either not observable or only partially observable. This complicates development and implementation of new smart grid technologies, such as those related to demand response, outage detection and management, and improved load-monitoring. In this two part paper, inspired by proliferation of the metering technology, we discuss estimation problems in structurally loopy but operationally radial distribution grids from measurements, e.g. voltage data, which are either already available or can be made available with a relatively minor investment. In Part I, the objective is to learn the operational layout of the grid. Part II of this paper presents algorithms that estimate load statistics or line parameters in addition to learning the grid structure. Further, Part II discusses the problem of structure estimation for systems with incomplete measurement sets. Our newly suggested algorithms apply to a wide range of realistic scenarios. The algorithms are also computationally efficient – polynomial in time– which is proven theoretically and illustrated computationally on a number of test cases. The technique developed can be applied to detect line failures in real time as well as to understand the scope of possible adversarial attacks on the grid.

  17. Inspection of cup-shaped steel parts from the I.D. side using eddy current

    Science.gov (United States)

    Griffiths, Erick W.; Pearson, Lee H.

    2018-04-01

    An eddy current method was developed to inspect cup-shaped steel parts from the I.D. side. During the manufacturing process of these parts, a thin Al tape foil is applied to the I.D. side of the part. One of the critical process parameters is that only one foil layer can be applied. An eddy current inspection system was developed to reject parts with more than one foil layer. The Al tape foil is cut to length to fit the inner diameter, however, after application of the foil there is a gap created between the beginning and end of the foil. It was found that this gap interfered with the eddy current inspection causing a false positive indication. To solve this problem a sensor design and data analysis process were developed to overcome the effects of these gaps. The developed system incorporates simultaneous measurements from multiple eddy current sensors and signal processing to achieve a reliable inspection.

  18. New technical solutions in nanotechnology. Part 4

    Directory of Open Access Journals (Sweden)

    IVANOV Leonid Alexeevich

    2016-10-01

    Full Text Available The new technical solutions including inventions in the area of nanotechnology and nanomaterials are efficiently applied in communal and housing services as well as in construction and other joint fields. The invention «The method to produce binder based on phenolformaldehyde resol resin for stratified material, binder and stratified material based on binder and reinforcing fiber base (RU 2594014» refers to polymer composite materials that can be used in manufacture of products designed for aircraft, construction, automobile and household industries. This method is based on component mixing. Resin and fospoliol are taken in dissolvent that is a mix of ethyl alcohol and dimethylformamide. This is the ratio of the components (mass.%: resin – 23,7, dissolvent – 75,3, fospoliol – 1,0. Nanomodifier – mechanically activated diamond - is dispersed into the obtained mixture. The mechanically activated diamond is produced in ball crusher when ration of ball mass and initial detonation nanodiamond is 20:1 respectively and the speed of ball rotation is 900 rotations per minute for 5 minutes. Stratified material based on binder and reinforcing paper fiber is based on aromatic polyamide and possesses finishing layer which composition contents polyamide, ethyl alcohol and water. The binder is applied evenly on the surface of finishing layer, its quantity is equal to the mass of fibers. The technical result is the binder on the basis of phenolformaldehyde resin without volatile flammable liquid and high-toxic substances, 3 times increased shift voltage for compressed products made of stratified materials and 1,3 time decreased inflammability of them. The specialists may be also interested in the following nanotechnological inventions: the method to produce carbon nanostructures modified by metal (RU 2593875; the method of deep purification of monosilane (RU 2593634; the method to produce conductive reticular micro- and nanostructures and the

  19. Argentina technical report

    International Nuclear Information System (INIS)

    2002-01-01

    At present, the Production Cyclotron Facility, installed at the Ezeiza Atomic Centre, is used for Tl-201 production; F-18 and I-123 production will be incorporated during this year. Concerning I-123 production, a system for irradiation of gaseous target has been developed in the frame of the IAEA Technical Assistance Project (ARG4085). The iodine production system delivers an ultra pure radioisotope via nuclear reactions: 124 Xe (p,2n) 123 Cs → 123 Xe → 123 I and 124 Xe (p,pn) 123 Xe → 123 I. This report describes the target and irradiation chamber design, the radiochemical purification process

  20. The Golden Age of Technical Communication

    Science.gov (United States)

    Kimball, Miles A.

    2017-01-01

    This article uses a historical perspective to describe the development of the profession of technical communication through three ages: Brass, Beige, and Glass. I compare this development to the growth of the academic discipline and both to the explosion of noninstitutional technical communication--the growing body of tactical technical…

  1. Cerenkov luminescence tomography based on preconditioning orthogonal matching pursuit

    Science.gov (United States)

    Liu, Haixiao; Hu, Zhenhua; Wang, Kun; Tian, Jie; Yang, Xin

    2015-03-01

    Cerenkov luminescence imaging (CLI) is a novel optical imaging method and has been proved to be a potential substitute of the traditional radionuclide imaging such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT). This imaging method inherits the high sensitivity of nuclear medicine and low cost of optical molecular imaging. To obtain the depth information of the radioactive isotope, Cerenkov luminescence tomography (CLT) is established and the 3D distribution of the isotope is reconstructed. However, because of the strong absorption and scatter, the reconstruction of the CLT sources is always converted to an ill-posed linear system which is hard to be solved. In this work, the sparse nature of the light source was taken into account and the preconditioning orthogonal matching pursuit (POMP) method was established to effectively reduce the ill-posedness and obtain better reconstruction accuracy. To prove the accuracy and speed of this algorithm, a heterogeneous numerical phantom experiment and an in vivo mouse experiment were conducted. Both the simulation result and the mouse experiment showed that our reconstruction method can provide more accurate reconstruction result compared with the traditional Tikhonov regularization method and the ordinary orthogonal matching pursuit (OMP) method. Our reconstruction method will provide technical support for the biological application for Cerenkov luminescence.

  2. Nutritional care of the elite child and adolescent athlete: Part I ...

    African Journals Online (AJOL)

    Nutritional care of the elite child and adolescent athlete: Part I - Energy and nutrient needs. ... assessed with skin folds or body fat percentages. Anthropometric measurements should be limited to twice yearly and too much ... 1300 mg calcium per day which can be achieved by having ~3 milk and/or dairy servings per day.

  3. Possibilities of computer tomography in multiple sclerosis

    International Nuclear Information System (INIS)

    Vymazal, J.; Bauer, J.

    1983-01-01

    Computer tomography was performed in 41 patients with multiple sclerosis, the average age of patients being 40.8 years. Native examinations were made of 17 patients, examinations with contrast medium of 19, both methods were used in the examination of 5 patients. In 26 patients, i.e. in almost two-thirds, cerebral atrophy was found, in 11 of a severe type. In 9 patients atrophy affected only the hemispheres, in 16 also the stem and cerebellum. The stem and cerebellum only were affected in 1 patient. Hypodense foci were found in 21 patients, i.e. more than half of those examined. In 9 there were multiple foci. In most of the 19 examined patients the hypodense changes were in the hemispheres and only in 2 in the cerebellum and brain stem. No hyperdense changes were detected. The value and possibilities are discussed of examinations by computer tomography multiple sclerosis. (author)

  4. The temporomandibular joint in computed tomography

    International Nuclear Information System (INIS)

    Pomaroli, A.; Lener, M.

    1988-01-01

    The first part describes details of the temporomandibular joint (TMJ) which are of interest for the examination by computed tomography. In the second part three new planes of reference for scanning of the ventral, middle or dorsal part of the joint are presented. CT examinations were made of 14 TMJ of corpses to identify the medial or ventral parts of the articular disc, medial wall of the articular capsule and medial or triangular recessus to achieve this were scanned the corpses with opened and closed mouth, as well as with closed sets of teeth using a sort of hypomochlion in the molar region to distract the TMJ. More over we applicated different contrast mediums like air and niob. (orig.) [de

  5. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  6. Electrical impedance tomography: topology optimization

    International Nuclear Information System (INIS)

    Miranda, Lenine Campos

    2013-01-01

    The Electrical Impedance Tomography (EIT) is a study of body parts who use electric current. Is studied through computers resistance or conductivity of these parts, producing an image used for medical diagnosis. A body is wrapped in a blanket placed with small electrodes and receivers of electric current, potential difference. Based on data obtained from a series of measurements at the electrodes, one by one, sending and receiving, you can perform a numerical phantom, where each 'voxel' of the image formed computationally represents the impedance of biological tissue. In Brazil, studies on electrical impedance tomography (EIT) has not yet started. Such equipment are measured tensions - potential difference - between each electrode / sensor one by one, as a way to Simple Combinatorial Analysis. The sequence and the way it is measured strains are in the final image quality. Finite Element Method Interactive, whose algorithm is based on Dialectical Method. We use an initial function with the objective of maximizing the data quantitatively, for better qualitative analysis. Topology Optimization methods are used to improve the image reconstruction. Currently the study is quite primitive related to the theory that shows how to power the new science studied. The high quality images requires a difficulty in obtaining. This work is not intended for detailed for analysis in any tissue or organ specific, but in general terms. And the formation of the 2D image. 3D need a reconstructor to part. (author)

  7. Image characterization metrics for muon tomography

    Science.gov (United States)

    Luo, Weidong; Lehovich, Andre; Anashkin, Edward; Bai, Chuanyong; Kindem, Joel; Sossong, Michael; Steiger, Matt

    2014-05-01

    Muon tomography uses naturally occurring cosmic rays to detect nuclear threats in containers. Currently there are no systematic image characterization metrics for muon tomography. We propose a set of image characterization methods to quantify the imaging performance of muon tomography. These methods include tests of spatial resolution, uniformity, contrast, signal to noise ratio (SNR) and vertical smearing. Simulated phantom data and analysis methods were developed to evaluate metric applicability. Spatial resolution was determined as the FWHM of the point spread functions in X, Y and Z axis for 2.5cm tungsten cubes. Uniformity was measured by drawing a volume of interest (VOI) within a large water phantom and defined as the standard deviation of voxel values divided by the mean voxel value. Contrast was defined as the peak signals of a set of tungsten cubes divided by the mean voxel value of the water background. SNR was defined as the peak signals of cubes divided by the standard deviation (noise) of the water background. Vertical smearing, i.e. vertical thickness blurring along the zenith axis for a set of 2 cm thick tungsten plates, was defined as the FWHM of vertical spread function for the plate. These image metrics provided a useful tool to quantify the basic imaging properties for muon tomography.

  8. Geometrical metrology on silicone rubber by computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Pacurar, Ramona Alexandra; De Chiffre, Leonardo

    2011-01-01

    Computed tomography (CT) represents a suitable measuring technique for investigation of deformable materials, since no forces are developed on the part during scanning. As for any other measuring instruments, the traceability of the CT scanners needs to be assured. An investigation on geometrical...

  9. 75 FR 81832 - Technical Service Provider Assistance

    Science.gov (United States)

    2010-12-29

    ... DEPARTMENT OF AGRICULTURE Natural Resources Conservation Service 7 CFR Part 652 Technical Service... as of Jan. 1, 2010, on page 565, in Sec. 652.2, the first definition for ``Technical service'' is removed. [FR Doc. 2010-32945 Filed 12-28-10; 8:45 am] BILLING CODE 1505-01-D ...

  10. Optical tomography of tissues

    International Nuclear Information System (INIS)

    Zimnyakov, D A; Tuchin, Valerii V

    2002-01-01

    Methods of optical tomography of biological tissues are considered, which include pulse-modulation and frequency-modulation tomography, diffusion tomography with the use of cw radiation sources, optical coherent tomography, speckle-correlation tomography of nonstationary media, and optoacoustic tomography. The method for controlling the optical properties of tissues is studied from the point of view of increasing a probing depth in optical coherent tomography. The modern state and prospects of the development of optical tomography are discussed. (review)

  11. Recovery of Navy distillate fuel from reclaimed product. Volume I. Technical discussion

    Energy Technology Data Exchange (ETDEWEB)

    Brinkman, D.W.; Whisman, M.L.

    1984-11-01

    In an effort to assist the Navy to better utilize its waste hydrocarbons, NIPER, with support from the US Department of Energy, is conducting research designed to ultimately develop a practical technique for converting Reclaimed Product (RP) into specification Naval Distillate Fuel (F-76). The first phase of the project was focused on reviewing the literature and available information from equipment manufacturers. The literature survey has been carefully culled for methodology applicable to the conversion of RP into diesel fuel suitable for Navy use. Based upon the results of this study, a second phase has been developed and outlined in which experiments will be performed to determine the most practical recycling technologies. It is realized that the final selection of one particular technology may be site-specific due to vast differences in RP volume and available facilities. A final phase, if funded, would involve full-scale testing of one of the recommended techniques at a refueling depot. The Phase I investigations are published in two volumes. Volume 1, Technical Discussion, includes the narrative and Appendices I and II. Appendix III, a detailed Literature Review, includes both a narrative portion and an annotated bibliography containing about 800 referenvces and abstracts. This appendix, because of its volume, has been published separately as Volume 2. 18 figures, 4 tables.

  12. Waveform tomography in geophysics and helioseismology

    NARCIS (Netherlands)

    Cobden, L.J.; Fichtner, A.; Tong, Vincent

    2015-01-01

    Seismic tomography – in which we construct images of a body's interior using seismic waves – is an inverse problem; that is, our goal is to find a model that fits a set of existing data observations. This is much less straightforward than the reverse, forward problem (i.e., generating synthetic data

  13. Prognostic impact of clinician-based interpretation of 18F-fluorodeoxyglucose positron emission tomography/computed tomography reports obtained in patients with newly diagnosed diffuse large B-cell lymphoma

    DEFF Research Database (Denmark)

    Mylam, Karen J; El-Galaly, Tarec C; Hutchings, Martin

    2014-01-01

    The aim of this study was to evaluate the prognostic value of clinician interpretation of positron emission tomography/computed tomography (PET/CT) reports at mid-therapy, interim PET (I-PET) and after the end of first-line therapy (E-PET) in patients with diffuse large B-cell lymphoma (DLBCL.......001) for positive, indeterminate and negative interpretation of PET/CT reports. Progression-free survival and OS did not differ significantly in patients with a negative and an indeterminate I-PET report. The use of well-defined reporting criteria, e.g. the Deauville five-point scale, is likely to reduce the number...

  14. Discussion on technical intelligence of nuclear power industry

    International Nuclear Information System (INIS)

    Chen Ming

    2010-01-01

    The very Paper introduces the contemporary challenges faced by the profession of technical intelligence on nuclear power, and expatiates the functions of technical intelligence such as sources of experience feedback, background information and supports for decision-making. Afterwards, the Paper explains characteristics of technical intelligence and its working methods, i.e., quantitative changes to reach qualitative changes, approve-negate-approve and oppositeness unity of comprehensiveness and limitation of technical intelligence. (authors)

  15. Public notice concerning the public funding of research and development work in the field of NMR tomography

    International Nuclear Information System (INIS)

    1982-01-01

    Brief survey of the projects financed from public funds for the promotion of technical developments, of specific contrast media for NMR tomography and related biomedical research work. The financial means and relevant contracts are distributed and concluded under the authority of the DFVLR, Department for Medical Research. (HP) [de

  16. In vivo measurement of haloperidol affinity to dopamine D2/D3 receptors by [123I]IBZM and single photon emission computed tomography

    DEFF Research Database (Denmark)

    Videbaek, C; Toska, K; Friberg, L

    2001-01-01

    This study examines the feasibility of a steady-state bolus-integration method with the dopamine D2/D3 receptor single photon emission computer tomography (SPECT) tracer, [123I]IBZM, for determination of in vivo affinity of haloperidol. The nonspecific binding of [123I]IBZM was examined in the rat...... brain by infusion of haloperidol to plasma levels approximately 100 times the Kd level in man. In humans, Kd for haloperidol binding was measured in four healthy volunteers that were examined twice: once with partial dopamine D2/D3 receptor blockade obtained by a scheduled infusion of unlabeled...... haloperidol (0.7 mg total dosage), and once in an unblocked state. Blood sampling and SPECT were performed intermittently during 6 hours after intravenous [123I]IBZM bolus injection. Plasma [123I]IBZM was determined by octane extraction. Plasma haloperidol was determined by a radioimmunoassay, and plasma...

  17. Enter the Madcap Prince of Wales: Students Directing "Henry IV, Part I."

    Science.gov (United States)

    Earthman, Elise Ann

    1993-01-01

    Argues that William Shakespeare's "Henry IV, Part I" is an appropriate and useful text for secondary English classrooms. Shows how the play lends itself to performance-based instruction. Outlines ways of accomplishing student engagement, using film versions, and assigning written work. (HB)

  18. Methodology for technical risk assessment

    International Nuclear Information System (INIS)

    Waganer, L.M.; Zuckerman, D.S.

    1983-01-01

    A methodology has been developed for and applied to the assessment of the technical risks associated with an evolving technology. This methodology, originally developed for fusion by K. W. Billman and F. R. Scott at EPRI, has been applied to assess the technical risk of a fuel system for a fusion reactor. Technical risk is defined as the risk that a particular technology or component which is currently under development will not achieve a set of required technical specifications (i.e. probability of failure). The individual steps in the technical risk assessment are summarized. The first step in this methodology is to clearly and completely quantify the technical requirements for the particular system being examined. The next step is to identify and define subsystems and various options which appear capable of achieving the required technical performance. The subsystem options are then characterized regarding subsystem functions, interface requirements with the subsystems and systems, important components, developmental obstacles and technical limitations. Key technical subsystem performance parameters are identified which directly or indirectly relate to the system technical specifications. Past, existing and future technical performance data from subsystem experts are obtained by using a Bayesian Interrogation technique. The input data is solicited in the form of probability functions. Thus the output performance of the system is expressed as probability functions

  19. An intelligent and integrated V and V environment design for NPP I and C software systems

    International Nuclear Information System (INIS)

    Koo, Seo Ryong; Son Han Seong; Seong, Poong Hyun

    2001-01-01

    Nuclear Power Plant (NPP) is the safety critical system. Since, nuclear instrumentation and control (I and C) systems including the plant protection system play the brain part of human, nuclear I and C systems have an influence on safety and operation of NPP. Essentially, software V and V should be performed for the safety critical systems based on software. It is very important in the technical aspect because of the problems concerning license acquisitions. In this work, an intelligent and integrated V and V environment supporting the automation of V and V was designed. The intelligent and integrated V and V environment consists of the intelligent controller part, components part, interface part, and GUI part. These parts were integrated systematically, while taking their own independent functions

  20. Technical recommendations for bilateral comparison in diagnosis radiology: part 2; Protocolo tecnico da comparacao bilateral em radiologia diagnostica: parte 2

    Energy Technology Data Exchange (ETDEWEB)

    Peixoto, J.G.P., E-mail: guilherm@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Almeida, C.E.V. de [Universidade do Estado do Rio de Janeiro (LCR/IBRAG/UERJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas

    2015-07-01

    The conventional radiology (≈70%), mammography(≈4%) and Computer Tomography (≈2%) will be in charge of this bilateral comparison. We could found the users ionization chambers, reference and radiations conditions, agenda and the comparison budget. The partial results will be presentation at metrology and medical physics congress. (author)

  1. Project GICC-Rhone Final report of part I; Projet GICC-Rhone Rapport final de tranche I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-12-15

    The project aims to give an evaluation of the impacts on the french Rhone basin, of the climatic change resulting of a double of the CO{sub 2} content in the atmosphere (possible in 2050). This report gives an evaluation of the researches progress. It describes the topic of the part I, the hydrological simulations realized and the analysis of the hydrological impacts. It provides also recommendations for the part II. The following topics are presented: the objectives of the project; the data and the atmospheric scenari construction methods on the Rhone basin under the climatic change; the used hydrological models; the results analysis in terms of hydrogeological impacts; the limits of the approach; and a bibliography. (A.L.B.)

  2. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[123I]iodoamphetamine (123I-IMP) in schizophrenia and atypical psychosis

    International Nuclear Information System (INIS)

    Suga, Hidemichi

    1993-01-01

    Sixteen schizophrenic patients, 16 atypical psychosis patients, and 16 healthy volunteers were subjected to single photon emission computed tomography (SPECT) of the brain using N-isopropyl-p-[ 123 I]iodoamphetamine ( 123 I-IMP). The basal ganglia region was in particular examined not only in transverse sections, but in coronal sections. Schizophrenics showed significantly decreased uptake rates in the bilateral frontal regions and increased uptakes in the bilateral basal ganglia. On the other hand, atypical psychotics had a reduced uptake rate only in the right thalamic region, compared to the controls. The increased uptake rates in the basal ganglia were associated with auditory hallucination, but gender difference, duration of illness and dose of neuroleptics had no influence on these SPECT findings. The results suggest that schizophrenics might have some lesions in the frontal area of the brain, whereas atypical psychotics might have no lesion in the frontal region but dysfunction in the right thalamic region. Subsequently, using only SPECT findings, all the cases were divided by cluster analysis into 4 groups and a residue group. Schizophrenics distributed mainly in the 2 groups that have lesion in the frontal regions. Atypical psychotics distributed principally in the other 2 groups that have alterations in the bilateral thalamic region. The present study suggests that schizophrenia and atypical psychosis might have different etiologies. (author)

  3. Positron emission tomography studies in the normal and abnormal ageing of human brain

    International Nuclear Information System (INIS)

    Comar, D.; Baron, J.C.

    1987-01-01

    Until recently, the investigation of the neurophysiological correlates of normal and abnormal ageing of the human brain was limited by methodological constraints, as the technics available provided only a few parameters (e.g. electroencephalograms, cerebral blood flow) monitored in superficial brain structures in a grossly regional and poorly quantitative way. Lately several non invasive techniques have been developed which allow to investigate in vivo both quantitatively and on local basis a number of previously inaccessible important aspects of brain function. Among these techniques, such as single photon emission tomography imaging of computerized electric events, nuclear magnetic resonance, positron emission tomography stands out as the most powerful and promising method since it allows the in vivo measurement of biochemical and pharmacological parameters

  4. On the Effects of Frequency Scaling Over Capacity Scaling in Underwater Networks—Part I

    DEFF Research Database (Denmark)

    Shin, Won-Yong; Roetter, Daniel Enrique Lucani; Médard, Muriel

    2013-01-01

    power-limited network. Interestingly, it is shown that the upper bound is intrinsically related to the attenuation parameter but not the spreading factor. Furthermore, we propose an achievable communication scheme based on the nearest-neighbor MH transmission, which is suitable due to the low......In this two-part paper, information-theoretic capacity scaling laws are analyzed in an underwater acoustic network with n regularly located nodes on a square, in which both bandwidth and received signal power can be limited significantly. Parts I and II deal with an extended network of unit node...... parameter that depends on the frequency scaling as well as the transmission distance. Upper and lower bounds on the capacity scaling are then derived. In Part I, we show that the upper bound on capacity for extended networks is inversely proportional to the attenuation parameter, thus resulting in a highly...

  5. Technical Note. The Concept of a Computer System for Interpretation of Tight Rocks Using X-Ray Computed Tomography Results

    Directory of Open Access Journals (Sweden)

    Habrat Magdalena

    2017-03-01

    Full Text Available The article presents the concept of a computer system for interpreting unconventional oil and gas deposits with the use of X-ray computed tomography results. The functional principles of the solution proposed are presented in the article. The main goal is to design a product which is a complex and useful tool in a form of a specialist computer software for qualitative and quantitative interpretation of images obtained from X-ray computed tomography. It is devoted to the issues of prospecting and identification of unconventional hydrocarbon deposits. The article focuses on the idea of X-ray computed tomography use as a basis for the analysis of tight rocks, considering especially functional principles of the system, which will be developed by the authors. The functional principles include the issues of graphical visualization of rock structure, qualitative and quantitative interpretation of model for visualizing rock samples, interpretation and a description of the parameters within realizing the module of quantitative interpretation.

  6. Japanese contributions to IAEA INTOR Workshop, Phase Two A, Part 3

    International Nuclear Information System (INIS)

    Mori, Shigeru; Tomabechi, Ken; Fujisawa, Noboru

    1988-02-01

    This report corresponds to Chapter I and II of Japanese contribution report to IAEA INTOR Workshop, Phase Two A, Part 3. The major objectives of the INTOR Workshop Part 3 are to evaluate innovative ideas which would significantly improve the tokamak concept, to study new-selected critical technical issues, that affect the feasibility or practicability of the INTOR concept, to assess scientific and technical data bases, and to conduct critical analyses of the existing INTOR-like designs with the aim of preparing a useful information base for future design work for ITER. To perform the innovations, critical issues, and data base, the following six groups are organized; (A) Impurity control, (B) Operational limits and confinement, (C) Current drive and heating, (D) Electromagnetics, (E) Configuration and maintenance, (F) Blanket and first wall. In addition to those groups, the two disciplinary groups are also organized to do the critical analyses of the existing INTOR-like designs; (G) Physics and (H) Engineering. (author)

  7. Optimal recombination in genetic algorithms for combinatorial optimization problems: Part I

    Directory of Open Access Journals (Sweden)

    Eremeev Anton V.

    2014-01-01

    Full Text Available This paper surveys results on complexity of the optimal recombination problem (ORP, which consists in finding the best possible offspring as a result of a recombination operator in a genetic algorithm, given two parent solutions. We consider efficient reductions of the ORPs, allowing to establish polynomial solvability or NP-hardness of the ORPs, as well as direct proofs of hardness results. Part I presents the basic principles of optimal recombination with a survey of results on Boolean Linear Programming Problems. Part II (to appear in a subsequent issue is devoted to the ORPs for problems which are naturally formulated in terms of search for an optimal permutation.

  8. Electrical impedance tomography spectroscopy method for characterising particles in solid-liquid phase

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yanlin [Department of Thermal Energy Engineering, College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing, 102249 (China); Wang, Mi [Institute of Particle Science and Engineering, School of Process, Environmental and Materials Engineering, University of Leeds, Leeds LS2 9JT (China); Yao, Jun [School of Energy Research, Xiamen University, Xiamen 361005 (China)

    2014-04-11

    Electrical impedance tomography (EIT) is one of the process tomography techniques to provide an on-line non-invasive imaging for multiphase flow measurement. With EIT measurements, the images of impedance real part, impedance imaginary part, phase angle, and magnitude can be obtained. However, most of the applications of EIT in the process industries rely on the conductivity difference between two phases in fluids to obtain the concentration profiles. It is not common to use the imaginary part or phase angle due to the dominant change in conductivity or complication in the use of other impedance information. In a solid-liquid two phases system involving nano- or submicro-particles, characterisation of particles (e.g. particle size and concentration) have to rely on the measurement of impedance phase angle or imaginary part. Particles in a solution usually have an electrical double layer associated with their surfaces and can form an induced electrical dipole moment due to the polarization of the electrical double layer under the influence of an alternating electric field. Similar to EIT, electrical impedance spectroscopy (EIS) measurement can record the electrical impedance data, including impedance real part, imaginary part and phase angle (θ), which are caused by the polarization of the electrical double layer. These impedance data are related to the particle characteristics e.g. particle size, particle and ionic concentrations in the aqueous medium, therefore EIS method provides a capability for characterising the particles in suspensions. Electrical impedance tomography based on EIS measurement or namely, electrical impedance tomography spectroscopy (EITS) could image the spatial distribution of particle characteristics. In this paper, a new method, including test set-up and data analysis, for characterisation of particles in suspensions are developed through the experimental approach. The experimental results on tomographic imaging of colloidal particles

  9. Nanotechnology and its relationship to interventional radiology. Part I: imaging.

    LENUS (Irish Health Repository)

    Power, Sarah

    2011-04-01

    Nanotechnology refers to the design, creation, and manipulation of structures on the nanometer scale. Interventional radiology stands to benefit greatly from advances in nanotechnology because much of the ongoing research is focused toward novel methods of imaging and delivery of therapy through minimally invasive means. Through the development of new techniques and therapies, nanotechnology has the potential to broaden the horizon of interventional radiology and ensure its continued success. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional radiology. Part I of the article deals with an introduction to some of the basic concepts of nanotechnology and outlines some of the potential imaging applications, concentrating mainly on advances in oncological and vascular imaging.

  10. Nanotechnology and its relationship to interventional radiology. Part I: imaging.

    LENUS (Irish Health Repository)

    Power, Sarah

    2012-02-01

    Nanotechnology refers to the design, creation, and manipulation of structures on the nanometer scale. Interventional radiology stands to benefit greatly from advances in nanotechnology because much of the ongoing research is focused toward novel methods of imaging and delivery of therapy through minimally invasive means. Through the development of new techniques and therapies, nanotechnology has the potential to broaden the horizon of interventional radiology and ensure its continued success. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional radiology. Part I of the article deals with an introduction to some of the basic concepts of nanotechnology and outlines some of the potential imaging applications, concentrating mainly on advances in oncological and vascular imaging.

  11. Nanotechnology and its Relationship to Interventional Radiology. Part I: Imaging

    International Nuclear Information System (INIS)

    Power, Sarah; Slattery, Michael M.; Lee, Michael J.

    2011-01-01

    Nanotechnology refers to the design, creation, and manipulation of structures on the nanometer scale. Interventional radiology stands to benefit greatly from advances in nanotechnology because much of the ongoing research is focused toward novel methods of imaging and delivery of therapy through minimally invasive means. Through the development of new techniques and therapies, nanotechnology has the potential to broaden the horizon of interventional radiology and ensure its continued success. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional radiology. Part I of the article deals with an introduction to some of the basic concepts of nanotechnology and outlines some of the potential imaging applications, concentrating mainly on advances in oncological and vascular imaging.

  12. Problems of fluorescent imaging and its solution using nanofluorophores. Part I: Advantages of fluorescent nanoparticles over conventional organic fluorophores

    International Nuclear Information System (INIS)

    Zhelev, Z.; Hadjidekov, G.; Zlateva, G.; Spasov, L.; Bakalova, R.

    2011-01-01

    The application of fluorescence in deep-tissue imaging is rapidly expanding in fast several years. The progress in fluorescent molecular probes and fluorescent imaging techniques gives an opportunity to detect single cells and even molecules in live organisms. The highly sensitive and high-speed fluorescent molecular sensors and detection devices allow the application of fluorescence in functional imaging. With development of novel bright fluorophores based on nano-technologies and fluorescence scanners with high spatial and temporal resolution, the fluorescent imaging has a potential to become an alternative of the other non-invasive imaging techniques as magnetic resonance imaging, positron-emission tomography, X-ray, computing tomography. This review outlines the current status and future trends of fluorescent nanoparticles - quantum dots (QDs), as a new generation of fluorophores in experimental and pre-clinical fluorescent imaging diagnostic. Part 1 focuses on the advantages of quantum dots over conventional organic fluorophores and defines the major requirements to the 'perfect' fluorophore for fluorescent deep-tissue imaging diagnostic. The analysis is based on the limitations of fluorescent imaging in vivo and overcome by using quantum dots

  13. New technical solutions in nanotechnology. Part 2

    Directory of Open Access Journals (Sweden)

    IVANOV Leonid Alexeevich

    2016-06-01

    Full Text Available The new technical solutions including inventions in the area of nanotechnology and nanomaterials are efficiently applied in communal and housing services as well as in construction and other joint fields. The invention «The diagnostics method for defects on the metal surfaces (RU 2581441» refers to the methods used to detect defects and cracks on the surface of metal equipment and pipe lines. The suspension of metal nanoparticles is consistently applied on the surface of controlled object following direction from the bigger diameter to the smaller one. The nanoparticles possess the photoluminescence property and their shape is spheric with different diameters. After each application the surface is dried and excessive particles are removed. Then rowwise scanning of object surface is executed with the ray of femtosecond laser and at the same time the intensity of the two-photon luminescence signal is registered in every studied area fixing the location of this area and obtaining the map of glow intensity distribution of nanoparticles exited by the laser radiation. The maps shows the zones with the maximal glow intensity, the coor dinates and shape of the determined glow zone make it possible to determine the coordinates and shape of the defect and the size of its intersection is considered to be equal to relative diameter of the applied nanoparticles at this application stage. The technical stage is increased reliability and credibility of the study. The specialists may be also interested in the following inventions: the method to produce forged pieces from fire-resistant granulated alloys (RU 2583564; the method to produce nanocomposite with double shape memory effect based on monocrystals of ferromagnetic alloy (RU 2583560; the method to produce nanostructured titanium-nickel-zirconium coatings with shape memory (RU 2583222; the method to produce nanocomposites based on golden nanoparticles covered with coating of silica oxide and quantum

  14. Environmental impacts on technical products

    International Nuclear Information System (INIS)

    1991-01-01

    The interaction between an object and its environment is examined by methods of environment simulation. With regard to possible synergisms, technical considerations and holistic thinking are essential. Environmental simulation is mainly concerned with questions of ability to function and the service life of technical products in their environment. The environmental simulation is used to discover cause/effect mechanisms in ageing and weathering processes. Questions of artificial ageing and speeded up time tests play a great part here. (orig.) [de

  15. Simulated lumbar minimally invasive surgery educational model with didactic and technical components.

    Science.gov (United States)

    Chitale, Rohan; Ghobrial, George M; Lobel, Darlene; Harrop, James

    2013-10-01

    The learning and development of technical skills are paramount for neurosurgical trainees. External influences and a need for maximizing efficiency and proficiency have encouraged advancements in simulator-based learning models. To confirm the importance of establishing an educational curriculum for teaching minimally invasive techniques of pedicle screw placement using a computer-enhanced physical model of percutaneous pedicle screw placement with simultaneous didactic and technical components. A 2-hour educational curriculum was created to educate neurosurgical residents on anatomy, pathophysiology, and technical aspects associated with image-guided pedicle screw placement. Predidactic and postdidactic practical and written scores were analyzed and compared. Scores were calculated for each participant on the basis of the optimal pedicle screw starting point and trajectory for both fluoroscopy and computed tomographic navigation. Eight trainees participated in this module. Average mean scores on the written didactic test improved from 78% to 100%. The technical component scores for fluoroscopic guidance improved from 58.8 to 52.9. Technical score for computed tomography-navigated guidance also improved from 28.3 to 26.6. Didactic and technical quantitative scores with a simulator-based educational curriculum improved objectively measured resident performance. A minimally invasive spine simulation model and curriculum may serve a valuable function in the education of neurosurgical residents and outcomes for patients.

  16. Contribution de la tomographie par coherence optique au diagnostic ...

    African Journals Online (AJOL)

    Contribution de la tomographie par coherence optique au diagnostic de la neuropathie optique toxique. C.O.A. Abouki, S Alamou, C.R.A. Assavedo, L Odoulami-Yehouessi, I Sounouvou, S Hounnou-Tchabi ...

  17. Designing Writing Assignments for Vocational-Technical Courses. A Guide for Teachers in the Two-Year College and Technical Institute.

    Science.gov (United States)

    Killingsworth, Jimmie, Ed.; And Others

    The 27 articles in this 6-part guide provide information on developing and implementing writing instruction as part of content-area courses in two-year vocational-technical colleges. Part One, General Concerns, includes "Making Writing Work for You in the Interactive Classroom" (Killingsworth, Rude); "Evaluating and Responding to Student Writing"…

  18. Evaluation of parapharyngeal space by computerized tomography and magnetic resonance. Part 1: anatomy

    International Nuclear Information System (INIS)

    Souza, Ricardo Pires de; Rapoport, Abrao

    1994-01-01

    The authors, through a comprehensive review of the literature, intend to establish an anatomical concept of the parapharyngeal space and its surroundings spaces in the supra-hyoid neck, based on its division by the fascial planes. The correlation between the anatomically defined parapharyngeal space and the findings of the sectional imaging procedures (computed tomography and magnetic resonance) is established, evidencing clear anatomic-radiologic correspondence. (author)

  19. The year 2013 in the European Heart Journal--Cardiovascular Imaging. Part I.

    Science.gov (United States)

    Edvardsen, Thor; Plein, Sven; Saraste, Antti; Pierard, Luc A; Knuuti, Juhani; Maurer, Gerald; Lancellotti, Patrizio

    2014-07-01

    The new multimodality cardiovascular imaging journal, European Heart Journal - Cardiovascular Imaging, was created in 2012. Here, we summarize the most important studies from the journal's second year in two articles. Part I of the review will focus on studies in myocardial function, myocardial ischaemia, and emerging techniques in cardiovascular imaging, and Part II will focus on valvular heart diseases, heart failure, cardiomyopathies, and congenital heart diseases. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  20. Designing carbon markets. Part I: Carbon markets in time

    International Nuclear Information System (INIS)

    Fankhauser, Samuel; Hepburn, Cameron

    2010-01-01

    This paper analyses the design of carbon markets in time (i.e., intertemporally). It is part of a twin set of papers that ask, starting from first principles, what an optimal global carbon market would look like by around 2030. Our focus is on firm-level cap-and-trade systems, although much of what we say would also apply to government-level trading and carbon offset schemes. We examine the 'first principles' of temporal design that would help to maximise flexibility and to minimise costs, including banking and borrowing and other mechanisms to provide greater carbon price predictability and credibility over time.

  1. The Technical Student Programme draws Norwegians

    CERN Multimedia

    2005-01-01

    Erik Hejne, second from left, Chairman of the Technical Students Committee, and Jens Vigen, who is concerned spefically with Norwegian students at CERN, with some of the Norwegian technical students who arrived at CERN in spring 2005, together with their teachers. From mid-April, CERN's PH and IT Departments are hosting ten Norwegian students from Bergen University College, the Sør-Trøndelag University College and the University of Science and Technology in Trondheim to take part in the Laboratory's Technical Student Programme. The Technical Student Programme is open to students of universities and technical higher education establishments in the Member States who, in the course of their studies, are required to complete a period of professional training in industry or in a laboratory. Around 70 Technical Students come to work at CERN each year. Selected by a committee, they spend between six months and one year with the Organization. The programme is funded by CERN. However, once the Laboratory's quota of...

  2. Technical reliability of geological disposal for high-level radioactive wastes in Japan. The second progress report. Introductory part and summaries

    International Nuclear Information System (INIS)

    1999-11-01

    Based on the Advisory Committee Report on Nuclear Fuel Cycle Backend Policy submitted to the Japanese Government in 1997, JNC documents the progress of research and development program in the form of the second progress report (the first one published in 1992). It summarizes an evaluation of the technical reliability and safety of the geological disposal concept for high-level radioactive wastes (HLW) in Japan and comprises seven chapters. Chapter I briefly describes the importance of HLW management in promoting nuclear energy utilization. According to the long-term program, the HLW separated from spent fuels at reprocessing plants is to be vitrified and stored for a period of 30 to 50 years to allow cooling, then be disposed of in a deep geological formation. Chapter II mainly explains the concepts of geological disposal in Japan. Chapters III to V are devoted to discussions on three important technical elements (the geological environment of Japan, engineering technology and safety assessment of the geological disposal system) which are necessary for reliable realization of the geological disposal concept. Chapter VI demonstrates the technical ground for site selection and for setup of safety standards of the disposal. Chapter VII summarizes together with plans for future research and development. (Ohno, S.)

  3. Design of site specific radiopharmaceuticals for tumor imaging. (Parts I and II)

    International Nuclear Information System (INIS)

    Van Dort, M.E.

    1983-01-01

    Part I. Synthetic methods were developed for the preparation of several iodinated benzoic acid hydrazides as labeling moieties for indirect tagging of carbonyl-containing bio-molecules and potential tumor-imaging agents. Biodistribution studies conducted in mice on the derivatives having the I-125 label ortho to a phenolic OH demonstrated a rapid in vivo deiodination. Part II. The reported high melanin binding affinity of quinoline and other heterocyclic antimalarial drugs led to the development of many analogues of such molecules as potential melanoma-imaging agents. Once such analogue iodochloroquine does exhibit high melanin binding, but has found limited clinical use due to appreciable accumulation in non-target tissues such as the adrenal cortex and inner ear. This project developed a new series of candidate melanoma imaging agents which would be easier to radio-label, could yield higher specific activity product, and which might demonstrate more favorable pharmacokinetic and dosimetric characteristics compared to iodochloroquine

  4. Pollution prevention opportunity assessment for Technical Art

    International Nuclear Information System (INIS)

    Torres, H.M.

    1995-09-01

    This pollution prevention opportunity assessment was conducted to evaluate Technical Art, which is part of the Technical Communications Department at Sandia National Laboratories/California. It is located in Building 912, Room 138. This assessment documents the processes, identifies the hazardous chemical waste streams generated by these processes, and recommends possible ways to minimize waste

  5. Upper crustal structure beneath East Java from ambient noise tomography: A preliminary result

    International Nuclear Information System (INIS)

    Martha, Agustya Adi; Widiyantoro, Sri; Cummins, Phil; Saygin, Erdinc; Masturyono

    2015-01-01

    East Java has a fairly complex geological structure. Physiographically East Java can be divided into three zones, i.e. the Southern Mountains zone in the southern part, the Kendeng zone in the middle part, and the Rembang zone in the northern part. Most of the seismic hazards in this region are due to processes in the upper crust. In this study, the Ambient Noise Tomography (ANT) method is used to image the upper crustal structure beneath East Java. We have used seismic waveform data recorded by 8Meteorological, Climatological and Geophysical Agency (BMKG) stationary seismographic stations and 16 portable seismographs installed for 2 to 8 weeks. The data were processed to obtain waveforms fromnoise cross-correlation between pairs of seismographic stations. Our preliminary results indicate that the Kendeng zone, an area of low gravity anomaly, is associated with a low velocity zone. On the other hand, the southern mountain range, which has a high gravity anomaly, is related to a high velocity anomaly as shown by our tomographic images

  6. Upper crustal structure beneath East Java from ambient noise tomography: A preliminary result

    Energy Technology Data Exchange (ETDEWEB)

    Martha, Agustya Adi [Meteorological, Climatological and Geophysical Agency, Jakarta (Indonesia); Graduate Research on Earthquakes and Active Tectonics, Institut Teknologi Bandung, Bandung (Indonesia); Widiyantoro, Sri [Global Geophysics Group, Institut Teknologi Bandung, Bandung (Indonesia); Center for Disaster Mitigation, Institut Teknologi Bandung, Bandung (Indonesia); Cummins, Phil; Saygin, Erdinc [Research School of Earth Sciences, Australian National University, Canberra (Australia); Masturyono [Meteorological, Climatological and Geophysical Agency, Jakarta (Indonesia)

    2015-04-24

    East Java has a fairly complex geological structure. Physiographically East Java can be divided into three zones, i.e. the Southern Mountains zone in the southern part, the Kendeng zone in the middle part, and the Rembang zone in the northern part. Most of the seismic hazards in this region are due to processes in the upper crust. In this study, the Ambient Noise Tomography (ANT) method is used to image the upper crustal structure beneath East Java. We have used seismic waveform data recorded by 8Meteorological, Climatological and Geophysical Agency (BMKG) stationary seismographic stations and 16 portable seismographs installed for 2 to 8 weeks. The data were processed to obtain waveforms fromnoise cross-correlation between pairs of seismographic stations. Our preliminary results indicate that the Kendeng zone, an area of low gravity anomaly, is associated with a low velocity zone. On the other hand, the southern mountain range, which has a high gravity anomaly, is related to a high velocity anomaly as shown by our tomographic images.

  7. Clinical optical coherence tomography combined with multiphoton tomography for evaluation of several skin disorders

    Science.gov (United States)

    König, Karsten; Speicher, Marco; Bückle, Rainer; Reckfort, Julia; McKenzie, Gordon; Welzel, Julia; Koehler, Martin J.; Elsner, Peter; Kaatz, Martin

    2010-02-01

    The first clinical trial of optical coherence tomography (OCT) combined with multiphoton tomography (MPT) and dermoscopy is reported. State-of-the-art (i) OCT systems for dermatology (e.g. multibeam swept source OCT), (ii) the femtosecond laser multiphoton tomograph DermaInspectTM, and (iii) digital dermoscopes were applied to 47 patients with a diversity of skin diseases and disorders such as skin cancer, psoriasis, hemangioma, connective tissue diseases, pigmented lesions, and autoimmune bullous skin diseases. Dermoscopy, also called 'epiluminescent microscopy', provides two-dimensional color images of the skin surface. OCT imaging is based on the detection of optical reflections within the tissue measured interferometrically whereas nonlinear excitation of endogenous fluorophores and the second harmonic generation are the bases of MPT images. OCT cross sectional "wide field" image provides a typical field of view of 5 x 2 mm2 and offers fast information on the depth and the volume of the investigated lesion. In comparison, multiphoton tomography presents 0.36 x 0.36 mm2 horizontal or diagonal sections of the region of interest within seconds with submicron resolution and down to a tissue depth of 200 μm. The combination of OCT and MPT provides a synergistic optical imaging modality for early detection of skin cancer and other skin diseases.

  8. Control of the working environment dosimetry and technical radiation protection at the RA reactor, Part I; Deo I: Kontrola radne sredine - poslovi dozimetrije i tehnicke zastite od zracenja kod reaktora RA

    Energy Technology Data Exchange (ETDEWEB)

    Ninkovic, N; Bjelanovic, J; Minicic, Z; Komatina, R; Raicevic, J [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1984-12-15

    This report contains data and analysis of the of measured sample results collected during radiation protection control in the working environment of the RA reactor. First part contains basic exposure values and statistical review of the the total number of radiation measurements. It includes contents of radioactive gasses and effluents in the air, as well as the level of surface contamination of clothes and uncovered parts of the personnel bodies. Second part deals with the analysis of personnel doses. It was found that the maximum individual dose from external irradiation amounted to 16.9 mSV during past 10 months. Individual exposures for 9/10 of the personnel were less than 1/10 of the permissible annual exposure. Data are compared to radiation doses for last year and previous five years. Third part of this annex contains basic data about the quantity of collected radioactive waste, total quantity of contaminated and decontaminated surfaces. The last part analyzes accidents occurred at the reactor during 1984. It was found that there have been no accidents that could cause significant contamination of working surfaces and components nor radiation exposure of the personnel.

  9. Technical support and emergency centre

    International Nuclear Information System (INIS)

    Bohun, L.; Kapisovsk y, M.

    1997-01-01

    This paper presents technical support and emergency management center which will be on two places: Mochovce NPP Emergency Centre (Technical support center and Support working center) and Reserve Emergency Centre in Levice (Reserve emergency center and Environmental Evaluation Center). The main aims of the emergency management centers are: the management and coordination of all persons and organisations; provision of the all information needed to evaluation of the accident and its mitigation; continuous evaluation of the potential or real radiological consequences; taking measure for an early notification of the governmental bodies and the organizations, warning and protection of the public; and other aims. In the next part the data for technical support and emergency centre are discussed

  10. Computed tomography in intracranial malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Naruse, S; Odake, G; Fujimoto, M; Yamaki, T; Mizukawa, N [Kyoto Prefectural Univ. of Medicine (Japan)

    1978-09-01

    Malignant lymphoma of the central nervous system has been found more and more often in recent years, partly because of the increased use of radiation and such drugs as steroids and antibiotics. However, the definite diagnosis of this disease is difficult until histological verification has been done by operation or autopsy. Since the revolutionary development of computed tomography, however, several reports have been presented, on the computed tomography of malignant lymphoma of the thorax and abdomen. Nevertheless, only a few cases of intracranial malignant lymphoma have been reported. The purpose of this paper, using four patients, is to emphasize the value of computed tomography in the diagnosis of intracranial malignant lymphoma. The characteristic CT findings of intracranial malignant lymphoma may be summarized follows: (1) the tumors are demonstrated to be well-defined, nodular-shaped, and homogenous isodensity - or slightly high-density - lesions in plain scans, and the tumors homogenously increase in density upon contrast enhancement; (2) the disease always has multifocal intracranial lesions, which are shown simultaneously or one after another, and (3) perifocal edema is prominent around the tumors in the cerebral hemisphere.

  11. Prolactin-secreting adenoma as part of the multiple endocrine neoplasia--type I (MEN-I) syndrome.

    Science.gov (United States)

    Levine, J H; Sagel, J; Rosebrock, G; Gonzalez, J J; Nair, R; Rawe, S; Powers, J M

    1979-06-01

    Two patients presented with the galactorrhea-amenorrhea syndrome. One patient had previously had parathyroid hyperplasia and the other an insulinoma. Preoperative evaluation of each patient revealed hyperprolactinemia and radiological evidence of an abnormal sella turcica. Pituitary adenomas were identified and removed at surgery. Immunostaining techniques confirmed the presence of prolactin-containing cells in both tumors. We propose that prolactin-secreting tumors be considered as part of the MEN-I syndrome, and that patients presenting with the galactorrhea-amenorrhea syndrome be screened and followed sequentially for evidence of other endocrine neoplasia.

  12. Evaluation of diffuse thyroid diseases by computed tomography and sup 123 I thyroidal uptake

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Yoshiko (Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine); Imanishi, Yoshimasa; Ehara, Norishige (and others)

    1991-10-01

    Understanding the iodine kinetics in the thyroid is useful for the diagnosis of a patient with diffuse thyroid disease. In this study, 9 controls and 50 patients with diffuse thyroid diseases, we evaluated diffuse thyroid diseases with {sup 123}I thyroidal uptake and volume, iodine concentration, and net iodine content measured by computed tomography. There was no significant correlation between volume, iodine concentration, and net iodine content of the thyroid and {sup 123}I thyroidal uptake. The thyroid volume in Graves' and Hashimoto's diseases was significantly larger than that in the control group. The thyroid iodine concentration in Graves' and Hashimoto's diseases was significantly smaller than that in the control group. The thyroid net iodine content in Hashimoto's disease was significantly smaller than that in the control group. Although most of the patients with Graves' disease had more increased radioiodine thyroidal uptake than the control group, there was no significant difference between them in the mean of the thyroid net iodine content. But the variance of net iodine contents in the former was significantly larger than that in the latter. The thyroid net iodine content was very low in all patients with very high thyroglobulin hemaggrugated antibody (TGHA) value although it was nearly normal in some patients with normal TGHA value. It was suggested that iodine concentration and net iodine content might be determined not only by iodine uptake but also by release and/or leakage of iodine compounds from the thyroid, which might depend on some antithyroid antibodies. (author).

  13. Manhattan Project Technical Series: The Chemistry of Uranium (I)

    International Nuclear Information System (INIS)

    Rabinowitch, E. I.; Katz, J. J.

    1947-01-01

    This constitutes Chapters 11 through 16, inclusive, of the Survey Volume on Uranium Chemistry prepared for the Manhattan Project Technical Series. Chapters are titled: Uranium Oxides, Sulfides, Selenides, and Tellurides; The Non-Volatile Fluorides of Uranium; Uranium Hexafluoride; Uranium-Chlorine Compounds; Bromides, Iodides, and Pseudo-Halides of Uranium; and Oxyhalides of Uranium.

  14. Manhattan Project Technical Series: The Chemistry of Uranium (I)

    Energy Technology Data Exchange (ETDEWEB)

    Rabinowitch, E. I. [Argonne National Lab. (ANL), Argonne, IL (United States); Katz, J. J. [Argonne National Lab. (ANL), Argonne, IL (United States)

    1947-03-10

    This constitutes Chapters 11 through 16, inclusive, of the Survey Volume on Uranium Chemistry prepared for the Manhattan Project Technical Series. Chapters are titled: Uranium Oxides, Sulfides, Selenides, and Tellurides; The Non-Volatile Fluorides of Uranium; Uranium Hexafluoride; Uranium-Chlorine Compounds; Bromides, Iodides, and Pseudo-Halides of Uranium; and Oxyhalides of Uranium.

  15. System for technical innovation support

    International Nuclear Information System (INIS)

    2011-08-01

    This book lists field of support system, which includes tax, development work, basic research project, industrial technology, information and communications field, energy field, part and materials field, local industry, the small and medium business such as technical development field, and industry-university collaboration like summary of investment and financing support and guarantee, support of manpower such as brain pool and contact Korea, support of technique like development technology and strategy for patent, support on certification such as company and technical goods, purchase support.

  16. Optical coherence tomography for imaging of skin and skin diseases

    DEFF Research Database (Denmark)

    Mogensen, Mette; Thrane, Lars; Jørgensen, Thomas Martini

    2009-01-01

    Optical coherence tomography (OCT) is an emerging imaging technology based on light reflection. It provides real-time images with up to 2-mm penetration into the skin and a resolution of approximately 10 μm. It is routinely used in ophthalmology. The normal skin and its appendages have been studi...... technical solutions are being pursued to further improve the quality of the images and the data provided, and OCT is being integrated in multimodal imaging devices that would potentially be able to provide a quantum leap to the imaging of skin in vivo....

  17. Class I structures license renewal industry report; revision 1. Final report

    International Nuclear Information System (INIS)

    Deng, D.; Renfro, J.; Statton, J.

    1994-07-01

    The U.S. nuclear power industry, through coordination by the Nuclear Management and Resources Council (NUMARC), and sponsorship by the U.S. Department of Energy (DOE) and the Electric Power Research Institute (EPRI), has evaluated age-related degradation effects for a number of major plant systems, structures, and components, in the license renewal technical Industry Reports (IRs). License renewal applicants may choose to reference these IRs in support of their plant-specific license renewal applications, as an equivalent to the integrated plant assessment provisions of the license renewal rule (10 CFR Part 54). This IR provides the technical basis for license renewal for U.S. nuclear power plant Class I structures, with the IR evaluating which structures are Class I. Seventeen structures are explicitly described and evaluated in this IR. These structures are not necessarily classified as Class I at all plants, therefore the license renewal applicant should consult this IR for correct identification

  18. Ambient Seismic Noise Interferometry on the Island of Hawai`i

    Science.gov (United States)

    Ballmer, Silke

    Ambient seismic noise interferometry has been successfully applied in a variety of tectonic settings to gain information about the subsurface. As a passive seismic technique, it extracts the coherent part of ambient seismic noise in-between pairs of seismic receivers. Measurements of subtle temporal changes in seismic velocities, and high-resolution tomographic imaging are then possible - two applications of particular interest for volcano monitoring. Promising results from other volcanic settings motivate its application in Hawai'i, with this work being the first to explore its potential. The dataset used for this purpose was recorded by the Hawaiian Volcano Observatory's permanent seismic network on the Island of Hawai'i. It spans 2.5 years from 5/2007 to 12/2009 and covers two distinct sources of volcanic tremor. After applying standard processing for ambient seismic noise interferometry, we find that volcanic tremor strongly affects the extracted noise information not only close to the tremor source, but unexpectedly, throughout the island-wide network. Besides demonstrating how this long-range observability of volcanic tremor can be used to monitor volcanic activity in the absence of a dense seismic array, our results suggest that care must be taken when applying ambient seismic noise interferometry in volcanic settings. In a second step, we thus exclude days that show signs of volcanic tremor, reducing the dataset to three months, and perform ambient seismic noise tomography. The resulting two-dimensional Rayleigh wave group velocity maps for 0.1 - 0.9 Hz compare very well with images from previous travel time tomography, both, for the main volcanic structures at low frequencies as well as for smaller features at mid-to-high frequencies - a remarkable observation for the temporally truncated dataset. These robust results suggest that ambient seismic noise tomography in Hawai'i is suitable 1) to provide a three-dimensional S-wave model for the volcanoes and 2

  19. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  20. Conventional X-ray examination and computed tomography in inflammatory rheumatic diseases

    International Nuclear Information System (INIS)

    Lingg, G.

    1996-01-01

    Plain-film radiography is an important and basic element in the assessment of inflammatory rheumatic diseases. Its various uses include assessment of inflammatory osseous destruction and the activity of inflammatory changes. Furthermore, the inflammatory collateral phenomena can indicate an acute clinical phase, and the articular soft tissue swelling and tenosynovitis are shown directly and indirectly very clearly. On the other hand, high-resolution computed tomography is very capable of showing cortical structures of bone complementary to MR. In some special clinical questions and anatomical regions, especially the axial skeleton, it delivers information of high specifity, partly for definitive diagnosis and partly for planning surgical procedures. The assessment of changes in the sacroiliac joints, sternoclavicular joints and craniocervical junction are domains of computed tomography. (orig.) [de

  1. Cardiac computed tomography in patients with acute coronary syndrome

    International Nuclear Information System (INIS)

    Schlett, C.L.; Bamberg, F.

    2014-01-01

    Currently, cardiac computed tomography (CT) is increasingly being implemented into clinical algorithms, primarily due to substantial technical advances over the last decade. Its use in the setting of suspected acute coronary syndrome is of particular relevance, given the high degree of accumulating scientific evidence of improving patient outcomes. Performing cardiac CT requires specific knowledge on the available scan acquisitions and patient preparation. Also, expertise is required in order to interpret the coronary and extra-coronary findings adequately. The present article provides an overview of the different aspects on the use of cardiac CT in the setting of acute coronary syndrome.

  2. Pictorial review: Electron beam computed tomography and multislice spiral computed tomography for cardiac imaging

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Dohmen, Pascal M.; Klessen, Christian; Wiese, Till H.; Hoffmann, Udo; Hamm, Bernd; Enzweiler, Christian N.H.

    2006-01-01

    Electron beam computed tomography (EBCT) revolutionized cardiac imaging by combining a constant high temporal resolution with prospective ECG triggering. For years, EBCT was the primary technique for some non-invasive diagnostic cardiac procedures such as calcium scoring and non-invasive angiography of the coronary arteries. Multislice spiral computed tomography (MSCT) on the other hand significantly advanced cardiac imaging through high volume coverage, improved spatial resolution and retrospective ECG gating. This pictorial review will illustrate the basic differences between both modalities with special emphasis to their image quality. Several experimental and clinical examples demonstrate the strengths and limitations of both imaging modalities in an intraindividual comparison for a broad range of diagnostic applications such as coronary artery calcium scoring, coronary angiography including stent visualization as well as functional assessment of the cardiac ventricles and valves. In general, our examples indicate that EBCT suffers from a number of shortcomings such as limited spatial resolution and a low contrast-to-noise ratio. Thus, EBCT should now only be used in selected cases where a constant high temporal resolution is a crucial issue, such as dynamic (cine) imaging. Due to isotropic submillimeter spatial resolution and retrospective data selection MSCT seems to be the non-invasive method of choice for cardiac imaging in general, and for assessment of the coronary arteries in particular. However, technical developments are still needed to further improve the temporal resolution in MSCT and to reduce the substantial radiation exposure

  3. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    Scutellari, Pier Nuccio; Galeotti, Roberto; Leprotti, Stefano; Piva, Nadia; Spanedda, Romedio

    1997-01-01

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  4. Technical Training: Places Available

    CERN Multimedia

    Monique Duval

    2004-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. Technical Training Monique Duval - Tel.74924 technical.training@cern.ch The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses: Oracle 9i: SQL: 17 - 19.5.2004 (3 days) Word 2003 - niveau 2 : 24 & 25.5.2004 (2 jours) EXCEL 2003 - niveau 1 : 27 & 28.5.2004 (2 jours) STEP7 Programming Level 1: 1 - 4.6.2004 (4 days) Oracle 9i : Programming with PL/SQL: 2 - 4.6.2004 (3 days) CST Microwave Studio: 3 & 4.6.2004 (2 days) Oracle 9i : New f...

  5. Serving Students Experiencing Homelessness under Title I, Part A. McKinney-Vento Law into Practice Brief Series

    Science.gov (United States)

    National Center for Homeless Education at SERVE, 2014

    2014-01-01

    The goal of Title I, Part A of the No Child Left Behind Act (NCLB) (20 U.S.C. § 6301 et seq) is to ensure that all children have a fair, equal, and significant opportunity to obtain a high-quality education and to reach proficiency on state standards and assessments of academic achievement. Title I, Part A is designed to meet the educational needs…

  6. Technical considerations in snubber reduction programs

    International Nuclear Information System (INIS)

    Longo, D.L.; Kitz, G.T.

    1989-01-01

    Snubber reduction has been a much discussed topic for the past several years. The advantages to the owner in terms of reduced radiation exposure, lower operating costs, and better plant maintainability are obvious but difficult to quantify. The costs associated with performing a snubber reduction program can be quantified, but can vary widely depending on how the program is implemented. One approach is to divide the scope of the work into several parts, based on similarities and differences of the plant systems and technical requirements. for example, for this program, the work was divided into three parts: nuclear steam supply system, torus-attached piping, and balance of plant. This approach facilitates addressing the variations in design requirements and the variations in snubber removal priorities that are related to each plant segment. It also allows the experience gained in the first part to be applied to the subsequent parts. This paper describes one utility's experience in successfully completing two parts of a three-part snubber reduction program and focuses on the various technical issues that must be addressed along with those areas where the utility should establish checkpoints that are critical to the success of the overall program. It also describes how the experience from the first two parts will be factored into the final part of the snubber reduction program

  7. 31 CFR 344.1 - What special terms do I need to know to understand this part?

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false What special terms do I need to know to understand this part? 344.1 Section 344.1 Money and Finance: Treasury Regulations Relating to... need to know to understand this part? As appropriate, the definitions of terms used in this part are...

  8. Training for Technical Assistants: Technical Assistance Program

    Science.gov (United States)

    1986-09-01

    shortage of technical ptfesson until such time as English , "speking instructors might be trained, There. would be An aumcation of committed on-calI...12 hours in classroom Instruction, students in English as a Second nel Research and Development Computer.taught students Language. The program Is...hbeels "p.-ogram. A Iot ’ atar boiler arn tank heats týe food enroute to its destination. 1.0. A new tor of dust ptectleon to protect machine .perators

  9. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  10. A framework for biodynamic feedthrough analysis--part I: theoretical foundations.

    Science.gov (United States)

    Venrooij, Joost; van Paassen, Marinus M; Mulder, Mark; Abbink, David A; Mulder, Max; van der Helm, Frans C T; Bulthoff, Heinrich H

    2014-09-01

    Biodynamic feedthrough (BDFT) is a complex phenomenon, which has been studied for several decades. However, there is little consensus on how to approach the BDFT problem in terms of definitions, nomenclature, and mathematical descriptions. In this paper, a framework for biodynamic feedthrough analysis is presented. The goal of this framework is two-fold. First, it provides some common ground between the seemingly large range of different approaches existing in the BDFT literature. Second, the framework itself allows for gaining new insights into BDFT phenomena. It will be shown how relevant signals can be obtained from measurement, how different BDFT dynamics can be derived from them, and how these different dynamics are related. Using the framework, BDFT can be dissected into several dynamical relationships, each relevant in understanding BDFT phenomena in more detail. The presentation of the BDFT framework is divided into two parts. This paper, Part I, addresses the theoretical foundations of the framework. Part II, which is also published in this issue, addresses the validation of the framework. The work is presented in two separate papers to allow for a detailed discussion of both the framework's theoretical background and its validation.

  11. Parotid-Absorbed Doses: A Comparison Between Spiral Tomography and Panoramic

    Directory of Open Access Journals (Sweden)

    Ehsan Hekmatian

    2016-07-01

    Full Text Available Background Jaws spiral tomography and panoramic radiography have wide applications in dentistry, and the parotid gland is one of the most sensitive organs of the head and neck. Objectives The aim of this study was to evaluate and compare the parotid-absorbed dose in spiral tomography and panoramic radiographs using a thermoluminescent dosimeter. Materials and Methods A radiation analog dosimetry phantom was placed in a Cranex Tome radiograph device, and a parotid absorbed dose was measured in both techniques. Thermoluminescent dosimeters were placed bilaterally in the parotid region (on the tube side and the opposite side. Spiral tomography dosimetry was done for the upper and lower jaws in the anterior and posterior regions. Each region contained four slices of 2 mm and four slices of 4 mm in thickness. The results were analyzed by a Wilcoxon test. Results For the tube side parotid, the average absorbed doses in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.70/1.40 and 1.65/1.60 mGy, respectively. The average absorbed doses with the 4mm slices were 1.65/1.70 and 1.75/1.57 mGy, respectively. For the opposite parotid, the average absorbed dose in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.40/1.30 and 1.40/1.67 mGy, respectively. The average absorbed doses with the 4mm slices were 1.50/1.66 and 1.40/1.50 mGy, respectively. The average absorbed dose of the panoramic radiograph was 1.40 mGy. Conclusions There was no statistically significant difference in the parotid absorbed dose between spiral tomography and a panoramic radiograph (P value = 0.18. The overall results of this study were similar to other studies.

  12. Parliamentarian sovereignty and technical development

    International Nuclear Information System (INIS)

    Dreier, H.; Hofmann, J.

    1986-01-01

    The title indicates the points of main emphasis of the contributions, and points to the programme embodied in the volume. The question is - given the tremendous and ever increasing amount of secondary problems associated with a heated technology development - whether the 'sovereign' state is at all capable of controlling, piloting and fostering technic-scientific processes. The first part ('sovereignty and parliamentarian legislator state') concentrates on the history of notions and ideas in the concept of the sovereign, modern state, and on the constitutional law in force (Dreier, Frohn); the current efficiency of parliament as an organ of control in the process of legislation is investigated (Schulze-Fielitz). The central concern of part 2 ('environmental law and technical development') are topical questions of environmental law (Hofmann, Luebbe-Wolff). Besides the analysis of dogmatic problems of a special administrative law, the major issue is whether and in how far - given modern large-scale technologies - law can adequately govern technique (Schmidt). By analyzing the relationship between technical development and possibilities for guidance by a parliamentarian constitutional state, the articles deal with a central point of intersection between state and administrative law. (orig./HP) [de

  13. High resolution tomography using analog coding

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.; Chesler, D.A.

    1985-01-01

    As part of a 30-year program in the development of positron instrumentation, the authors have developed a high resolution bismuth germanate (BGO) ring tomography (PCR) employing 360 detectors and 90 photomultiplier tubes for one plane. The detectors are shaped as trapezoid and are 4 mm wide at the front end. When assembled, they form an essentially continuous cylindrical detector. Light from a scintillation in the detector is viewed through a cylindrical light pipe by the photomultiplier tubes. By use of an analog coding scheme, the detector emitting light is identified from the phototube signals. In effect, each phototube can identify four crystals. PCR is designed as a static device and does not use interpolative motion. This results in considerable advantage when performing dynamic studies. PCR is the positron tomography analog of the γ-camera widely used in nuclear medicine

  14. Stem cells in dentistry--part I: stem cell sources.

    Science.gov (United States)

    Egusa, Hiroshi; Sonoyama, Wataru; Nishimura, Masahiro; Atsuta, Ikiru; Akiyama, Kentaro

    2012-07-01

    Stem cells can self-renew and produce different cell types, thus providing new strategies to regenerate missing tissues and treat diseases. In the field of dentistry, adult mesenchymal stem/stromal cells (MSCs) have been identified in several oral and maxillofacial tissues, which suggests that the oral tissues are a rich source of stem cells, and oral stem and mucosal cells are expected to provide an ideal source for genetically reprogrammed cells such as induced pluripotent stem (iPS) cells. Furthermore, oral tissues are expected to be not only a source but also a therapeutic target for stem cells, as stem cell and tissue engineering therapies in dentistry continue to attract increasing clinical interest. Part I of this review outlines various types of intra- and extra-oral tissue-derived stem cells with regard to clinical availability and applications in dentistry. Additionally, appropriate sources of stem cells for regenerative dentistry are discussed with regard to differentiation capacity, accessibility and possible immunomodulatory properties. Copyright © 2012 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  15. 15 CFR Appendix I to Part 700 - Form BIS-999-Request for Special Priorities Assistance

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Form BIS-999-Request for Special Priorities Assistance I Appendix I to Part 700 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE NATIONAL...

  16. 36 CFR 1212.115 - Does this part affect the Federal contracts that I receive?

    Science.gov (United States)

    2010-07-01

    ... ARCHIVES AND RECORDS ADMINISTRATION GENERAL RULES GOVERNMENTWIDE REQUIREMENTS FOR DRUG-FREE WORKPLACE (FINANCIAL ASSISTANCE) Purpose and Coverage § 1212.115 Does this part affect the Federal contracts that I...

  17. Technical Education--The Key to Sustainable Technological Development

    Science.gov (United States)

    Odo, J. U.; Okafor, W. C.; Odo, A. L.; Ejikeugwu, L. N.; Ugwuoke, C. N.

    2017-01-01

    Technical education has been identified as one of the most effective human resource development that needs to be embraced for rapid industrialization and sustainable technological development of any nation. Technical education has been an integral part of national development in many societies because of its impact on productivity and economic…

  18. Writing Clinic for Business and Technical Writers.

    Science.gov (United States)

    Mercer County Community Coll., Trenton, NJ.

    This document offers brief lesson plans for four courses: (1) an 8-hour refresher course for employees who write memos, short reports, and letters; (2) an 8-hour refresher course on creating a short document; (3) a 16-hour course on technical manual writing; and (4) an 8-hour course on technical manual writing. The courses were part of a workplace…

  19. Guidelines for writing user friendly technical specifications

    International Nuclear Information System (INIS)

    Webster, S.A.; Braun, J.C.; Pearce, R.T.

    1986-01-01

    This study investigates some of the ergonomic considerations of writer's guides for the preparation of instructions. It is a precedent for the preparation of such a writer's guide for technical specifications for nuclear power plants. This writer's guide will be part of a revision to the industry's standard ANSI/ANS 58.4, Criteria for Technical Specifications for Nuclear Power Stations

  20. Technical writing in the radiologic technology curriculum.

    Science.gov (United States)

    Bell, R

    1979-01-01

    Although courses in technical writing are no longer suggested in the Curriculum Guide for Programs in Radiologic Technology, the writer believes that writing is essential to the growth of the profession and development of the professional. Emphasis is placed on some of the benefits that accrue to students who are exposed to technical writing as part of their technology curriculum.

  1. Technical and economic limits to fuel burnup extension. Proceedings of a technical committee meeting

    International Nuclear Information System (INIS)

    2002-07-01

    For many years, the increase of efficiency in the production of nuclear electricity has been an economic challenge in many countries which have developed this kind of energy. The increase of fuel burnup leads to a reduction in the volume of spent fuel discharged to longer fuel cycles in the reactor, which means bigger availability and capacity factors. After having increased the authorized burnup in plants, developing new alloys capable of resisting high burnup, and having accumulated data on fuel evolution with burnup, it has become necessary to establish the limitations which could be imposed by the physical evolution of the fuel, influencing fuel management, neutron properties, reprocessing or, more generally, the management of waste and irradiated fuels. It is also necessary to verify whether the benefits of lower electricity costs would not be offset by an increase in fuel management costs. The main questions are: Are technical and economic limits to the increasing of fuel burnup in parallel? Can we envisage nowadays the hardest limitation in some of these areas? Which are the main points to be solved from the technical point of view? Is this effort worthwhile considering the economy of the cycle? To which extent? For these reasons, the IAEA, following a recommendation by the International Working Group on Fuel Performance and Technology, held a Technical Committee Meeting on Technical and Economic Limits to Fuel Burnup Extension. The purpose of this meeting was to provide an international forum to review the evolution of fuel properties at increased burnup in order to estimate the limitations both from a physical and an economic point of view. The meeting was therefore divided into two parts. The first part, focusing on technical limits, was devoted to the improvement of the fuel element, such as fission gas release (FGR), RIM effect, cladding, etc. and the fabrication, core management, spent fuel and reprocessing. Eighteen related papers were presented which

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  3. Advanced Combustion and Emission Control Technical Team Roadmap

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-06-01

    The Advanced Combustion and Emission Control (ACEC) Technical Team is focused on removing technical barriers to the commercialization of advanced, high-efficiency, emission-compliant internal combustion (IC) engines for light-duty vehicle powertrains (i.e., passenger car, minivan, SUV, and pickup trucks).

  4. Technical challenges for dismantlement verification

    International Nuclear Information System (INIS)

    Olinger, C.T.; Stanbro, W.D.; Johnston, R.G.; Nakhleh, C.W.; Dreicer, J.S.

    1997-01-01

    In preparation for future nuclear arms reduction treaties, including any potential successor treaties to START I and II, the authors have been examining possible methods for bilateral warhead dismantlement verification. Warhead dismantlement verification raises significant challenges in the political, legal, and technical arenas. This discussion will focus on the technical issues raised by warhead arms controls. Technical complications arise from several sources. These will be discussed under the headings of warhead authentication, chain-of-custody, dismantlement verification, non-nuclear component tracking, component monitoring, and irreversibility. The authors will discuss possible technical options to address these challenges as applied to a generic dismantlement and disposition process, in the process identifying limitations and vulnerabilities. They expect that these considerations will play a large role in any future arms reduction effort and, therefore, should be addressed in a timely fashion

  5. Dose Reduction and Dose Management in Computed Tomography - State of the Art.

    Science.gov (United States)

    Zinsser, Dominik; Marcus, Roy; Othman, Ahmed E; Bamberg, Fabian; Nikolaou, Konstantin; Flohr, Thomas; Notohamiprodjo, Mike

    2018-03-13

     For years, the number of performed CT examinations has been rising. At the same time, computed tomography became more dose efficient. The aim of this article is to give an overview about the state of the art in dose reduction in CT and to highlight currently available tools in dose management.  By performing a literature research on Pubmed regarding dose reduction in CT, relevant articles were identified and analyzed.  Technical innovations with individual adaptation of tube current and voltage as well as iterative image reconstruction enable a considerable dose reduction with preserved image quality. At the same time, dedicated software tools are able to handle huge amounts of data and allow to optimize existing examination protocols.   · CT examinations are increasingly performed and contribute considerably to non-natural radiation exposure.. · A correct indication is crucial for each CT examination.. · The examination protocol has to be tailored to the medical question and patient.. · Multiple technical innovations enable considerable dose reduction with constant image quality.. · Dose management with dedicated software tools gains importance.. · Zinsser D, Marcus R, Othman AE et al. Dose reduction and dose management in computed tomography - State of the art. Fortschr Röntgenstr 2018; DOI: 10.1055/s-0044-101261. © Georg Thieme Verlag KG Stuttgart · New York.

  6. An update on technical and methodological aspects for cardiac PET applications

    International Nuclear Information System (INIS)

    PRESOTTO, Luca; BUSNARDO, Elena; GIANOLLI, Luigi; BETTINARDI, Valentino

    2016-01-01

    Positron emission tomography (PET) is indicated for a large number of cardiac diseases: perfusion and viability studies are commonly used to evaluate coronary artery disease; PET can also be used to assess sarcoidosis and endocarditis, as well as to investigate amyloidosis. Furthermore, a hot topic for research is plaque characterization. Most of these studies are technically very challenging. High count rates and short acquisition times characterize perfusion scans while very small targets have to be imaged in inflammation/infection and plaques examinations. Furthermore, cardiac PET suffers from respiratory and cardiac motion blur. Each type of studies has specific requirements from the technical and methodological point of view, thus PET systems with overall high performances are required. Furthermore, in the era of hybrid PET/computed tomography (CT) and PET/Magnetic Resonance Imaging (MRI) systems, the combination of complementary functional and anatomical information can be used to improve diagnosis and prognosis. Moreover, PET images can be qualitatively and quantitatively improved exploiting information from the other modality, using advanced algorithms. In this review we will report the latest technological and methodological innovations for PET cardiac applications, with particular reference to the state of the art of the hybrid PET/CT and PET/MRI. We will also report the most recent advancements in software, from reconstruction algorithms to image processing and analysis programs.

  7. 14 CFR Appendix I to Part 25 - Installation of an Automatic Takeoff Thrust Control System (ATTCS)

    Science.gov (United States)

    2010-01-01

    ... Appendix I to Part 25—Installation of an Automatic Takeoff Thrust Control System (ATTCS) I25.1General. (a... crew to increase thrust or power. I25.2Definitions. (a) Automatic Takeoff Thrust Control System (ATTCS... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Installation of an Automatic Takeoff Thrust...

  8. How to find technical information. Vol. 1. 2. rev. ed.

    International Nuclear Information System (INIS)

    Joswig, W.; Heidtmann, F.

    1987-01-01

    This introduction into the technique of finding and procuring special technical literature is addressed to students and post-graduate students engaged in this work. The part on library organization contains a sketch on how to procure information, while the part dealing with bibliographical material lists the most important instruments for the retrieval of special technical information. A library and bibliographical terminology and an index are appended. (DG) [de

  9. N-Loop Learning: Part I--of Hedgehog, Fox, Dodo Bird and Sphinx

    Science.gov (United States)

    Simonin, Bernard L.

    2017-01-01

    Purpose: This paper aims to encourage greater clarity and stimulate further interest in thorough empirical research in the area of learning levels. The broader motivation here is to urge researchers to not only theorize but also undertake elaborate and much needed empirical work. Design/methodology/approach Part I of the study rests on a…

  10. Nonoperative treatment of splenic trauma: usefulness of computed tomography

    International Nuclear Information System (INIS)

    Resende, Vivian; Tavares Junior, Wilson Campos; Vieira, Jose Nelson Mendes; Drumond, Domingos Andre Fernandes

    2005-01-01

    Objective: to report the results of use of conservative treatment in patients with splenic trauma and to emphasize the usefulness of computed tomography in these cases. Material and method: sixty-nine cases of pediatric patients with blunt abdominal trauma seen from from January 2001 to June 2004 at the level I trauma center were retrospectively studied. Forty-four of these patients were submitted to nonoperative treatment and the clinical follow-up was performed by computerized tomography. All patients had been diagnosed with splenic injury by computerized tomography.Results: the causes of the injuries were motor vehicle accident in 12 (27.2%) patients, bicycle accident in nine (20.4%) patients, and falls in 23 (52.2%) patients. Two (3.7%) patients died from associated injuries. The mean duration of hospital stay was six days. The mean age of the patients was nine years. Conclusion: conservative treatment for blunt splenic trauma is performed with the aim of reducing costs and risks for the patients, and computerized tomography should be routinely used. No posterior complications were observed in this approach. (author)

  11. Comparison of two ring artefact removal filters used for neutron tomography reconstruction

    International Nuclear Information System (INIS)

    Vontobel, P.

    2007-01-01

    Full text of publication follows: The reduction of ring artefacts in transmission tomography reconstruction, by filtering sino-grams, is a common practice for most radiation modalities. Using simulated and measured neutron transmission data, an analysis of two ring artefact suppression schemes is given. The choice of the ring filtering parameters has to take the noise characteristics of the measured raw projection data into account. Introduction The appearance of ring artefacts in transmission tomography data is quite common. They are due to deficiencies in the measured projections and show as vertical lines in the sinogram representation of all projections of a single slice. A vertical line in the sinogram is due to a single pixel or a group of n pixels on the detector, which is less or more sensitive than the average pixel and shows even after flat-field correction. Most annoying ring artefacts are due to partly dead pixels, which cannot be identified easily on the projection images. Their effect only show in the sinogram or later on the reconstructed slice images. Therefore ring artefact mitigation starts with the analysis of sinogram images or analysis of reconstructed slices. Analysis of two ring filtering algorithms: The first ring filtering method sums first sinogram rows (i.e. over all angles) and divides it by the number of rows (ave) and generate a smoothed version of this sum (smoothing width 3,5,7,9 pixels). The difference diff = ave - smooth(ave) is then subtracted from each row. This is a very simple and efficient correction scheme. The second method relies on morphological filtering the sinogram i.e. using a combination of a morphological 'Top hat' and a 'Bot hat' operation on the data. A filtering threshold is determined depending on the number of detected lines in the sinogram. Summary and conclusion: Using simulated an measured neutron transmission data two ring filtering algorithms are evaluated. A careful choice of filtering parameters is

  12. Computerized transverse tomography of vascular lesions of the brain. I. Arteriovenous malformations

    International Nuclear Information System (INIS)

    Pressman, B.D.; Kirkwood, J.R.; Davis, D.O.

    1975-01-01

    Computerized transverse tomography (CTT) of the brain is a recently developed method which allows non-invasive roentgenologic evaluation of intracranial disease. Since its inception, major attention has been given to the diagnosis and evaluation of tumors, clots, infarcts, venticular size, and orbital lesions. The purpose of this report is to discuss the application of CTT to the diagnosis and evaluation of intracerebral arteriovenous malformations. (U.S.)

  13. Teaching and Learning the Nature of Technical Artifacts

    Science.gov (United States)

    Frederik, Ineke; Sonneveld, Wim; de Vries, Marc J.

    2011-01-01

    Artifacts are probably our most obvious everyday encounter with technology. Therefore, a good understanding of the nature of technical artifacts is a relevant part of technological literacy. In this article we draw from the philosophy of technology to develop a conceptualization of technical artifacts that can be used for educational purposes.…

  14. Fuzzy modeling of electrical impedance tomography images of the lungs

    International Nuclear Information System (INIS)

    Tanaka, Harki; Ortega, Neli Regina Siqueira; Galizia, Mauricio Stanzione; Borges, Joao Batista; Amato, Marcelo Britto Passos

    2008-01-01

    Objectives: Aiming to improve the anatomical resolution of electrical impedance tomography images, we developed a fuzzy model based on electrical impedance tomography's high temporal resolution and on the functional pulmonary signals of perfusion and ventilation. Introduction: Electrical impedance tomography images carry information about both ventilation and perfusion. However, these images are difficult to interpret because of insufficient anatomical resolution, such that it becomes almost impossible to distinguish the heart from the lungs. Methods: Electrical impedance tomography data from an experimental animal model were collected during normal ventilation and apnoea while an injection of hypertonic saline was administered. The fuzzy model was elaborated in three parts: a modeling of the heart, the pulmonary ventilation map and the pulmonary perfusion map. Image segmentation was performed using a threshold method, and a ventilation/perfusion map was generated. Results: Electrical impedance tomography images treated by the fuzzy model were compared with the hypertonic saline injection method and computed tomography scan images, presenting good results. The average accuracy index was 0.80 when comparing the fuzzy modeled lung maps and the computed tomography scan lung mask. The average ROC curve area comparing a saline injection image and a fuzzy modeled pulmonary perfusion image was 0.77. Discussion: The innovative aspects of our work are the use of temporal information for the delineation of the heart structure and the use of two pulmonary functions for lung structure delineation. However, robustness of the method should be tested for the imaging of abnormal lung conditions. Conclusions: These results showed the adequacy of the fuzzy approach in treating the anatomical resolution uncertainties in electrical impedance tomography images. (author)

  15. Computerized tomography and conventional radiography: A comparison from the standpoint of X-ray physics and technology

    Energy Technology Data Exchange (ETDEWEB)

    Pfeiler, M; Linke, G [Siemens A.G., Erlangen (Germany, F.R.). Unternehmensbereich Medizinische Technik

    1979-08-01

    After a short explantation of the technical foundations of computerized tomography (CT) from terms used in conventional X-ray technique and CT the differences (dose distribution, image character) and similarities (quantum noise, beam quality) of both methods are discussed. Finally possible methods of quantitative evaluation of CT images and computation of longitudinal layers from a series of computerized tomograms are described. (author).

  16. An Evaluation of Mandibular Dental and Basal Arch Dimensions in Class I and Class II Division 1 Adult Syrian Patients using Cone-beam Computed Tomography.

    Science.gov (United States)

    Al-Hilal, Layal H; Sultan, Kinda; Hajeer, Mohammad Y; Mahmoud, Ghiath; Wanli, Abdulrahman A

    2018-04-01

    Aim: The aim of this study is (1) to inspect any difference in mandibular arch widths between males and females in class I and class II division 1 (class malocclusions using cone-beam computed tomography (CBCT), (2) to compare the mandibular dental and basal widths between the two groups, and (3) to investigate any possible correlation between dental and basal arch widths in both groups. Materials and methods: The CBCT images of 68 patients aged between 18 and 25 years consisted of 34 class I (17 males and 17 females) and 34 class (17 males and 17 females) who were recruited at the Department of Orthodontics, University of Damascus Dental School (Syria). Using on-demand three-dimensional (3D) on axial views, facial axis points for dental measurements and basal bone center (BBC) points for basal measurements were identified on lower canines and first molars. Dental and basal intercanine width (ICW) and intermolar width (IMW) were measured. Results: Independent t-test showed a statistically significant difference between males and females in several variables in both groups and a statistically significant difference between class I and class groups in the basal ICW for both genders and in the dental ICW for females only (p class I group, Pearson's correlation coefficients between dental and basal measurements showed a strong correlation in the IMW for both genders (r > 0.73; p class group, a moderate correlation in females' IMW (r = 0.67; p Class I patients had larger ICW than class II-1 patients in all measurements and had narrower IMW than class in most measurements for both genders. There were moderate-to-strong correlations between dental and basal dimensions. BBC points might be landmarks that accurately represent the basal bone arch. Clinical significance: CBCT-based assessments of dental and basal arch dimensions provide a great opportunity to accurately evaluate these aspects, to enhance clinicians' decisions regarding proper tooth movements, and to achieve

  17. Multidetector row computed tomography in bowel obstruction. Part 2. Large bowel obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)]. E-mail: rakesh.sinha@uhl-tr.nhs.uk; Verma, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)

    2005-10-01

    Large bowel obstruction may present as an emergency as high-grade colonic obstruction and can result in perforation. Perforated large bowel obstruction causes faecal peritonitis, which can result in high morbidity and mortality. Multidetector row computed tomography (MDCT) has the potential of providing an accurate diagnosis of large bowel obstruction. The rapid acquisition of images within one breath-hold reduces misregistration artefacts than can occur in critically ill or uncooperative patients. The following is a review of the various causes of large bowel obstruction with emphasis on important pathogenic factors, CT appearances and the use of multiplanar reformatted images in the diagnostic workup.

  18. Technical writing versus technical writing

    Science.gov (United States)

    Dillingham, J. W.

    1981-01-01

    Two terms, two job categories, 'technical writer' and 'technical author' are discussed in terms of industrial and business requirements and standards. A distinction between 'technical writing' and technical 'writing' is made. The term 'technical editor' is also considered. Problems inherent in the design of programs to prepare and train students for these jobs are discussed. A closer alliance between industry and academia is suggested as a means of preparing students with competent technical communication skills (especially writing and editing skills) and good technical skills.

  19. Vibration mechanism's isolation installed on the compliant base (Part I: Question State)

    International Nuclear Information System (INIS)

    Djuma, R.

    2001-01-01

    The main reason of noise and vibration aggravation in houses is the considerable increase of the number of sources because of building being equipped with engineering, sanitary, technical and other mechanical equipment (lifts, pumps, ventilation, conditioner, systems and others). Very often the equipment installed on the building's coverings, is not favorable from the acoustics point of view, in comparison with equipment that is installed on separate foundation or in the basement. Vibrations that appear on the coverings in the mechanism work through the joints and transfer to the joining buildings that in their part while vibration will take the sound of the adjacent buildings. Working in the mean time normative documents on projecting of machine's vibroisolation and equipment that guide projectors and builder's, recommend to make calculations of vibroisolation on the dynamic loading that is created by working equipment only on the basic vibration frequency. (author)

  20. Ulnar-sided wrist pain. Part I: anatomy and physical examination

    International Nuclear Information System (INIS)

    Vezeridis, Peter S.; Blazar, Philip; Yoshioka, Hiroshi; Han, Roger

    2010-01-01

    Ulnar-sided wrist pain is a common complaint, and it presents a diagnostic challenge for hand surgeons and radiologists. The complex anatomy of this region, combined with the small size of structures and subtle imaging findings, compound this problem. A thorough understanding of ulnar-sided wrist anatomy and a systematic clinical examination of this region are essential in arriving at an accurate diagnosis. In part I of this review, ulnar-sided wrist anatomy and clinical examination are discussed for a more comprehensive understanding of ulnar-sided wrist pain. (orig.)

  1. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part II: On 3D model accuracy

    International Nuclear Information System (INIS)

    Liang Xin; Lambrichts, Ivo; Sun Yi; Denis, Kathleen; Hassan, Bassam; Li Limin; Pauwels, Ruben; Jacobs, Reinhilde

    2010-01-01

    Aim: The study aim was to compare the geometric accuracy of three-dimensional (3D) surface model reconstructions between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: A dry human mandible was scanned with five CBCT systems (NewTom 3G, Accuitomo 3D, i-CAT, Galileos, Scanora 3D) and one MSCT scanner (Somatom Sensation 16). A 3D surface bone model was created from the six systems. The reference (gold standard) 3D model was obtained with a high resolution laser surface scanner. The 3D models from the five systems were compared with the gold standard using a point-based rigid registration algorithm. Results: The mean deviation from the gold standard for MSCT was 0.137 mm and for CBCT were 0.282, 0.225, 0.165, 0.386 and 0.206 mm for the i-CAT, Accuitomo, NewTom, Scanora and Galileos, respectively. Conclusion: The results show that the accuracy of CBCT 3D surface model reconstructions is somewhat lower but acceptable comparing to MSCT from the gold standard.

  2. In Vivo Diffuse Optical Tomography and Fluorescence Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Mingze Li

    2010-01-01

    Full Text Available Diffuse optical tomography (DOT and fluorescence molecular tomography (FMT are two attractive imaging techniques for in vivo physiological and psychological research. They have distinct advantages such as non-invasiveness, non-ionizing radiation, high sensitivity and longitudinal monitoring. This paper reviews the key components of DOT and FMT. Light propagation model, mathematical reconstruction algorithm, imaging instrumentation and medical applications are included. Future challenges and perspective on optical tomography are discussed.

  3. 10 CFR Appendix I to Part 960 - NRC and EPA Requirements for Postclosure Repository Performance

    Science.gov (United States)

    2010-01-01

    ... SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Pt. 960, App. I Appendix I to Part 960—NRC and... after disposal (a) releases of radioactive materials to the accessible environment that are estimated to...,000 years for a repository containing wastes generated from 100,000 metric tons of heavy metal of...

  4. Dose measurements with a HPGe detector - a technical manual

    Energy Technology Data Exchange (ETDEWEB)

    Lidstroem, K.; Nordenfors, C.; Aagren, G

    2000-06-01

    This paper is a technical manual for estimations of dose based on a gamma spectrum. The method used is based on the Monte Carlo code EGS4. Since dose estimations from spectra are specific for each detector, this work is performed on two mobile HPGe detectors at FOA NBC Defence in Umeaa. This technical manual describes the method used in three steps: Part 1 explains how to construct a model of the detector geometry and the specific material for a new detector. Part 2 describes the underlying work of Monte Carlo simulations of a detector given geometry and material. Part 3 describes dose estimations from a gamma spectrum.

  5. Quantitative imaging of magnetic nanoparticles by magneto-relaxometric tomography for biomedical applications; Quantitative Bildgebung magnetischer Nanopartikel mittels magnetrelaxometrischer Tomographie fuer biomedizinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Liebl, Maik

    2016-11-18

    Current biomedical research focuses on the development of novel biomedical applications based on magnetic nanoparticles (MNPs), e.g. for local cancer treatment. These therapy approaches employ MNPs as remotely controlled drug carriers or local heat generators. Since location and quantity of MNPs determine drug enrichment and heat production, quantitative knowledge of the MNP distribution inside a body is essential for the development and success of these therapies. Magnetorelaxometry (MRX) is capable to provide such quantitative information based on the specific response of the MNPs after switching-off an applied magnetic field. Applying a uniform (homogeneous) magnetic field to a MNP distribution and measuring the MNP response by multiple sensors at different locations allows for spatially resolved MNP quantification. However, to reconstruct the MNP distribution from this spatially resolved MRX data, an ill posed inverse problem has to be solved. So far, the solution of this problem was stabilized incorporating a-priori knowledge in the forward model, e.g. by setting priors on the vertical position of the distribution using a 2D reconstruction grid or setting priors on the number and geometry of the MNP sources inside the body. MRX tomography represents a novel approach for quantitative 3D imaging of MNPs, where the inverse solution is stabilized by a series of MRX measurements. In MRX tomography, only parts of the MNP distribution are sequentially magnetized by the use of inhomogeneous magnetic fields. Each magnetizing is followed by detection of the response of the corresponding part of the distribution by multiple sensors. The 3D reconstruction of the MNP distribution is then accomplished by a common evaluation of the distinct MRX measurement series. In this thesis the first experimental setup for MRX tomography was developed for quantitative 3D imaging of biomedical MNP distributions. It is based on a multi-channel magnetizing unit which has been engineered to

  6. Cerebral blood flow single-photon emission tomography with 123I-IMP in vascular dementia

    International Nuclear Information System (INIS)

    Kawahata, Nobuya; Gotoh, Chiharu; Yokoyama, Sakura; Daitoh, Nobuyuki

    2001-01-01

    Cerebral blood flow differences between patients with vascular dementia, patients with multiple lacunar infarction without cognitive dysfunction, and age-matched controls were examined. Thirty four patients with vascular dementia (VD) were selected from consecutive referrals to the Memory Clinic at Narita Memorial Hospital. All the patients had routine assessment including history, physical and neurological examinations, neuropsychological assessment, blood tests, EEG, head MRI, and single photon emission computed tomography (SPECT). All of them fulfilled the NINDS-AIREN diagnostic criteria for vascular dementia. Thirty nine patients with multiple lacunar infarction without cognitive dysfunction and 110 age-matched controls were included in this study. Mean cerebral blood flow (mCBF) and regional cerebral blood flow (rCBF) were measured using N-isopropyl-P- 123 I-iodoamphetamine ( 123 I-IMP) and SPECT imager. The mCBF in VD was 27.6±5.3 ml/100 g/min, while those in the control group and multiple lacunar infarction without cognitive dysfunction were 36.6±6.1 ml/100 g/min and 32.5±5.5 ml/100 g/min, respectively. The patients with VD demonstrated significantly reduced mCBF and rCBF in twenty regions including both cerebellar hemispheres as compared with those of the control group. Although there was no significant rCBF differences in bilateral inferior occipital regions and the right cerebellar hemisphere between patients with VD and multiple lacunar infarction without cognitive dysfunction, we could find significant lower rCBF in the remaining brain areas. In spite of the severity of VD, the diffuse decrease of cerebral blood flow was recognized in all patients with VD. (author)

  7. Paramedics' non-technical skills: a literature review.

    Science.gov (United States)

    Shields, Allan; Flin, Rhona

    2013-05-01

    Healthcare organisations have started to examine the impact that the human worker has on patient safety. Adopting the Crew Resource Management (CRM) approach, used in aviation, the CRM or non-technical skills of anaesthetists, surgeons, scrub practitioners and emergency physicians have recently been identified to assist in their training and assessment. Paramedics are exposed to dynamic and dangerous situations where patients have to be managed, often with life-threatening injuries or illness. As in other safety-critical domains, the technical skills of paramedics are complemented by effective non-technical skills. The aim of this paper was to review the literature on the non-technical (social and cognitive) skills used by paramedics. This review was undertaken as part of a task analysis to identify the non-technical skills used by paramedics. Of the seven papers reviewed, the results have shown very little research on this topic and so reveal a gap in the understanding of paramedic non-technical skills.

  8. Sport Specialization, Part I

    Science.gov (United States)

    Myer, Gregory D.; Jayanthi, Neeru; Difiori, John P.; Faigenbaum, Avery D.; Kiefer, Adam W.; Logerstedt, David; Micheli, Lyle J.

    2015-01-01

    Context: There is increased growth in sports participation across the globe. Sports specialization patterns, which include year-round training, participation on multiple teams of the same sport, and focused participation in a single sport at a young age, are at high levels. The need for this type of early specialized training in young athletes is currently under debate. Evidence Acquisition: Nonsystematic review. Study Design: Clinical review. Level of Evidence: Level 4. Conclusion: Sports specialization is defined as year-round training (greater than 8 months per year), choosing a single main sport, and/or quitting all other sports to focus on 1 sport. Specialized training in young athletes has risks of injury and burnout, while the degree of specialization is positively correlated with increased serious overuse injury risk. Risk factors for injury in young athletes who specialize in a single sport include year-round single-sport training, participation in more competition, decreased age-appropriate play, and involvement in individual sports that require the early development of technical skills. Adults involved in instruction of youth sports may also put young athletes at risk for injury by encouraging increased intensity in organized practices and competition rather than self-directed unstructured free play. Strength-of-Recommendation Taxonomy (SORT): C. PMID:26502420

  9. Fetal neuroimaging: an update on technical advances and clinical findings.

    Science.gov (United States)

    Robinson, Ashley J; Ederies, M Ashraf

    2018-04-01

    This paper is based on a literature review from 2011 to 2016. The paper is divided into two main sections. The first section relates to technical advances in fetal imaging techniques, including fetal motion compensation, imaging at 3.0 T, 3-D T2-weighted MRI, susceptibility-weighted imaging, computed tomography, morphometric analysis, diffusion tensor imaging, spectroscopy and fetal behavioral assessment. The second section relates to clinical updates, including cerebral lamination, migrational anomalies, midline anomalies, neural tube defects, posterior fossa anomalies, sulcation/gyration and hypoxic-ischemic insults.

  10. Technical Training: Places available

    CERN Multimedia

    Monique Duval

    2005-01-01

    The number of places available may vary. Please check our Web site to find out the current availability. Places are available on the following courses: LabVIEW Real-Time (F) : 7 - 9.6.2005 (3 jours) LabVIEW Migration 6 to 7: 14.6.2005 (1 day) IT3T/1 - Read your mail and more with Outlook 2003 : 14.6.2005 (IT Technical Training Tutorial, free of charge) IT3T/2 - Creating, managing and using distribution lists with Simba2 : 16.6.2005 (IT Technical Training Tutorial, free of charge) FrontPage 2003 - niveau 2 : 16 & 17.6.2005 (2 jours) Utilisation de fichiers PDF avec ACROBAT 6.0 : 20.6.2005 (1journée) Introduction to ANSYS: 21 - 24.6.2005 (4 days) IT3T/3 - Working remotely with Windows XP : 28.6.2005 (IT Technical Training Tutorial, free of charge) IT3T/4 - Editing Websites with Frontpage 2003 : 30.6.2005 (IT Technical Training Tutorial, free of charge) WORD 2003 (Short Course I) - HowTo... Work with repetitive tasks /AutoText, AutoFormat, AutoC...

  11. Standard technical specifications for Babcock and Wilcox pressurized water reactors. Revision 4. Technical report

    International Nuclear Information System (INIS)

    Virgilio, M.J.

    1980-10-01

    The Standard Technical Specifications for Babcock and Wilcox Pressurized Water Reactors (BandW-STS) is a generic document prepared by the U.S. NRC for use in the licensing process. The BandW-STS provide applicants with model specifications to be used in formulation plant-specific technical specifications required by 10 CFR Part 50, Section 50.36, which set forth the specific characteristics of the facility and the conditions for its operation that are required to provide adequate protection to the health and safety of the public. This document is revised periodically to reflect current licensing requirements

  12. Somatostatin receptor positron emission tomography/computed tomography (PET/CT) in the evaluation of opsoclonus-myoclonus ataxia syndrome

    International Nuclear Information System (INIS)

    Joshi, Prathamesh; Lele, Vikram

    2013-01-01

    Opsoclonus-myoclonus ataxia (OMA) syndrome is the most common paraneoplastic neurological syndrome of childhood, associated with occult neuroblastoma in 20%-50% of all cases. OMA is the initial presentation of neuroblastoma in 1%-3% of children. Conventional radiological imaging approaches include chest radiography and abdominal computed tomography (CT). Nuclear medicine techniques, in form of 123 I/ 131 I-metaiodobenzylguanidine (MIBG) scintigraphy have been incorporated in various diagnostic algorithms for evaluation of OMA. We describe use of somatostatin receptor PET/CT with 68 Gallium- DOTA-DPhe 1 , Tyr 3 -octreotate (DOTATATE) in diagnosis of neuroblastoma in two cases of OMA

  13. Somatostatin receptor positron emission tomography/computed tomography (PET/CT) in the evaluation of opsoclonus-myoclonus ataxia syndrome.

    Science.gov (United States)

    Joshi, Prathamesh; Lele, Vikram

    2013-04-01

    Opsoclonus-myoclonus ataxia (OMA) syndrome is the most common paraneoplastic neurological syndrome of childhood, associated with occult neuroblastoma in 20%-50% of all cases. OMA is the initial presentation of neuroblastoma in 1%-3% of children. Conventional radiological imaging approaches include chest radiography and abdominal computed tomography (CT). Nuclear medicine techniques, in form of (123)I/(131)I-metaiodobenzylguanidine (MIBG) scintigraphy have been incorporated in various diagnostic algorithms for evaluation of OMA. We describe use of somatostatin receptor PET/CT with (68)Gallium- DOTA-DPhe(1), Tyr(3)-octreotate (DOTATATE) in diagnosis of neuroblastoma in two cases of OMA.

  14. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[[sup 123]I]iodoamphetamine ([sup 123]I-IMP) in schizophrenia and atypical psychosis

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Hidemichi (Aichi Medical Univ., Nagakute (Japan))

    1993-05-01

    Sixteen schizophrenic patients, 16 atypical psychosis patients, and 16 healthy volunteers were subjected to single photon emission computed tomography (SPECT) of the brain using N-isopropyl-p-[[sup 123]I]iodoamphetamine ([sup 123]I-IMP). The basal ganglia region was in particular examined not only in transverse sections, but in coronal sections. Schizophrenics showed significantly decreased uptake rates in the bilateral frontal regions and increased uptakes in the bilateral basal ganglia. On the other hand, atypical psychotics had a reduced uptake rate only in the right thalamic region, compared to the controls. The increased uptake rates in the basal ganglia were associated with auditory hallucination, but gender difference, duration of illness and dose of neuroleptics had no influence on these SPECT findings. The results suggest that schizophrenics might have some lesions in the frontal area of the brain, whereas atypical psychotics might have no lesion in the frontal region but dysfunction in the right thalamic region. Subsequently, using only SPECT findings, all the cases were divided by cluster analysis into 4 groups and a residue group. Schizophrenics distributed mainly in the 2 groups that have lesion in the frontal regions. Atypical psychotics distributed principally in the other 2 groups that have alterations in the bilateral thalamic region. The present study suggests that schizophrenia and atypical psychosis might have different etiologies. (author).

  15. Differentially Encoded LDPC Codes—Part I: Special Case of Product Accumulate Codes

    Directory of Open Access Journals (Sweden)

    (Tiffany JingLi

    2008-01-01

    Full Text Available Part I of a two-part series investigates product accumulate codes, a special class of differentially-encoded low density parity check (DE-LDPC codes with high performance and low complexity, on flat Rayleigh fading channels. In the coherent detection case, Divsalar's simple bounds and iterative thresholds using density evolution are computed to quantify the code performance at finite and infinite lengths, respectively. In the noncoherent detection case, a simple iterative differential detection and decoding (IDDD receiver is proposed and shown to be robust for different Doppler shifts. Extrinsic information transfer (EXIT charts reveal that, with pilot symbol assisted differential detection, the widespread practice of inserting pilot symbols to terminate the trellis actually incurs a loss in capacity, and a more efficient way is to separate pilots from the trellis. Through analysis and simulations, it is shown that PA codes perform very well with both coherent and noncoherent detections. The more general case of DE-LDPC codes, where the LDPC part may take arbitrary degree profiles, is studied in Part II Li 2008.

  16. 31 CFR 380.3 - What collateral may I pledge if I am a Treasury Tax and Loan depositary under 31 CFR part 203...

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false What collateral may I pledge if I am a Treasury Tax and Loan depositary under 31 CFR part 203, and what value will you assign to it? 380...) FISCAL SERVICE, DEPARTMENT OF THE TREASURY BUREAU OF THE PUBLIC DEBT COLLATERAL ACCEPTABILITY AND...

  17. The lived experiences of operating theatre scrub nurses learning technical scrub skills 'I'm doing this right, aren't I? Am I doing this right?'

    Science.gov (United States)

    Radford, Eleanor J; Fotis, Theo

    2018-01-01

    Operating theatre scrub nurses (OTSNs) are not required to have undertaken a secondary or specialist post-registration theatre qualification to work in the operating theatre (OT) setting in the UK. From the systematic review there is only very limited literature or research in how technical scrub skills are acquired. This study explores the lived experiences of OTSNs learning technical scrub skills. The study employed the qualitative methodology of interpretative phenomenological analysis. Data was collected from six participating OTSNs using semi-structured interviews. Four superordinate themes emerged: How technical scrub skills are established, Gatekeepers, How the learner feels whilst learning and, Reflections of the experienced scrub nurse. The study found that the experiences of OTSNs learning technical scrub skills are varied and a variety of teaching and learning methods are utilised. These experiences were influenced by the team, mentor and surgeon within the OT environment. Lived experiences were also influenced by organisational structure and service pressures within the NHS.

  18. Correlative single photon emission computed tomography imaging of [{sup 123}I]altropane binding in the rat model of Parkinson's

    Energy Technology Data Exchange (ETDEWEB)

    Gleave, Jacqueline A. [Department of Pathology and Molecular Medicine, McMaster University, 1200 Main Street West, Hamilton, Ontario, L8N 3Z5 (Canada); Farncombe, Troy H.; Saab, Chantal [Department of Nuclear Medicine, Hamilton Health Sciences, Hamilton, Ontario, L8N 3Z5 (Canada); Doering, Laurie C., E-mail: doering@mcmaster.ca [Department of Pathology and Molecular Medicine, McMaster University, 1200 Main Street West, Hamilton, Ontario, L8N 3Z5 (Canada)

    2011-07-15

    Introduction: This study used the dopamine transporter (DAT) probe, [{sup 123}I]-2{beta}-carbomethoxy-3{beta}-(4-fluorophenyl)-N-(3-iodo-E-allyl)nortropane ([{sup 123}I]altropane), to assess the DAT levels in the 6-hydroxydopamine rat model of Parkinson's disease. We sought to assess if the right to left [{sup 123}I]altropane striatal ratios correlated with dopamine content in the striatum and substantia nigra and with behavioural outcomes. Methods: [{sup 123}I]altropane images taken pre- and postlesion were acquired before and after the transplantation of neural stem/progenitor cells. The images obtained using [{sup 123}I]altropane and single photon emission computed tomography (SPECT) were compared with specific behavioural tests and the dopamine content assessed by high-performance liquid chromatography. Results: [{sup 123}I]altropane binding correlated with the content of dopamine in the striatum; however, [{sup 123}I]altropane binding did not correlate with the dopamine content in the substantia nigra. There was a significant correlation of altropane ratios with the cylinder test and the postural instability test, but not with amphetamine rotations. The low coefficient of determination (r{sup 2}) for these correlations indicated that [{sup 123}I]altropane SPECT was not a good predictor of behavioural outcomes. Conclusion: Our data reveal that [{sup 123}I]altropane predicts the integrity of the striatal dopamine nerve terminals, but does not predict the integrity of the nigrostriatal system. [{sup 123}I]altropane could be a useful marker to measure dopamine content in cell replacement therapies; however, it would not be able to evaluate outcomes for neuroprotective strategies.

  19. Development and applications of STIM- and PIXE-tomography: A review

    International Nuclear Information System (INIS)

    Michelet, C.; Barberet, P.; Moretto, P.; Seznec, H.

    2015-01-01

    In combination with nuclear microprobes, STIM and PIXE tomography offer non-destructive quantitative three-dimensional characterization of microscopic samples. STIM tomography provides 3D density maps of the analyzed sample with sub-micrometer resolution and PIXE tomography is one of the only methods allowing a quantification of trace elements in three dimensions. These tomography techniques have been developed in several microbeam laboratories around the world since the 80’s. Nevertheless, despite a huge interest in mapping the inner content of a sample without destroying it, the use of ion beam tomography has been limited to a few studies up to now. This comes from the specific requirements of this kind of experiments, i.e. specific experimental set-up (rotation of the sample during analysis) and reconstruction software, making this type of experiments difficult to handle and relatively long. For a few years, efforts have been made to facilitate the implementation of these techniques and reduce the duration of data acquisition: new detectors and new algorithms were proposed. After an introduction to ion beam tomography techniques and to the first developments made in that field, the experimental and data processing specificities of this 3D imaging approach will be discussed. Finally, examples of recent applications to biology and material science are presented, as well as related techniques developed in the field of microbeam 3D imaging.

  20. Development and applications of STIM- and PIXE-tomography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Michelet, C., E-mail: michelet@cenbg.in2p3.fr; Barberet, P., E-mail: barberet@cenbg.in2p3.fr; Moretto, P., E-mail: moretto@cenbg.in2p3.fr; Seznec, H., E-mail: herve.seznec@cenbg.in2p3.fr

    2015-11-15

    In combination with nuclear microprobes, STIM and PIXE tomography offer non-destructive quantitative three-dimensional characterization of microscopic samples. STIM tomography provides 3D density maps of the analyzed sample with sub-micrometer resolution and PIXE tomography is one of the only methods allowing a quantification of trace elements in three dimensions. These tomography techniques have been developed in several microbeam laboratories around the world since the 80’s. Nevertheless, despite a huge interest in mapping the inner content of a sample without destroying it, the use of ion beam tomography has been limited to a few studies up to now. This comes from the specific requirements of this kind of experiments, i.e. specific experimental set-up (rotation of the sample during analysis) and reconstruction software, making this type of experiments difficult to handle and relatively long. For a few years, efforts have been made to facilitate the implementation of these techniques and reduce the duration of data acquisition: new detectors and new algorithms were proposed. After an introduction to ion beam tomography techniques and to the first developments made in that field, the experimental and data processing specificities of this 3D imaging approach will be discussed. Finally, examples of recent applications to biology and material science are presented, as well as related techniques developed in the field of microbeam 3D imaging.

  1. Photoacoustic tomography of human hepatic malignancies using intraoperative indocyanine green fluorescence imaging.

    Directory of Open Access Journals (Sweden)

    Akinori Miyata

    Full Text Available Recently, fluorescence imaging following the preoperative intravenous injection of indocyanine green has been used in clinical settings to identify hepatic malignancies during surgery. The aim of this study was to evaluate the ability of photoacoustic tomography using indocyanine green as a contrast agent to produce representative fluorescence images of hepatic tumors by visualizing the spatial distribution of indocyanine green on ultrasonographic images. Indocyanine green (0.5 mg/kg, intravenous was preoperatively administered to 9 patients undergoing hepatectomy. Intraoperatively, photoacoustic tomography was performed on the surface of the resected hepatic specimens (n = 10 under excitation with an 800 nm pulse laser. In 4 hepatocellular carcinoma nodules, photoacoustic imaging identified indocyanine green accumulation in the cancerous tissue. In contrast, in one hepatocellular carcinoma nodule and five adenocarcinoma foci (one intrahepatic cholangiocarcinoma and 4 colorectal liver metastases, photoacoustic imaging delineated indocyanine green accumulation not in the cancerous tissue but rather in the peri-cancerous hepatic parenchyma. Although photoacoustic tomography enabled to visualize spatial distribution of ICG on ultrasonographic images, which was consistent with fluorescence images on cut surfaces of the resected specimens, photoacoustic signals of ICG-containing tissues decreased approximately by 40% even at 4 mm depth from liver surfaces. Photoacoustic tomography using indocyanine green also failed to identify any hepatocellular carcinoma nodules from the body surface of model mice with non-alcoholic steatohepatitis. In conclusion, photoacoustic tomography has a potential to enhance cancer detectability and differential diagnosis by ultrasonographic examinations and intraoperative fluorescence imaging through visualization of stasis of bile-excreting imaging agents in and/or around hepatic tumors. However, further technical

  2. Photoacoustic tomography of human hepatic malignancies using intraoperative indocyanine green fluorescence imaging.

    Science.gov (United States)

    Miyata, Akinori; Ishizawa, Takeaki; Kamiya, Mako; Shimizu, Atsushi; Kaneko, Junichi; Ijichi, Hideaki; Shibahara, Junji; Fukayama, Masashi; Midorikawa, Yutaka; Urano, Yasuteru; Kokudo, Norihiro

    2014-01-01

    Recently, fluorescence imaging following the preoperative intravenous injection of indocyanine green has been used in clinical settings to identify hepatic malignancies during surgery. The aim of this study was to evaluate the ability of photoacoustic tomography using indocyanine green as a contrast agent to produce representative fluorescence images of hepatic tumors by visualizing the spatial distribution of indocyanine green on ultrasonographic images. Indocyanine green (0.5 mg/kg, intravenous) was preoperatively administered to 9 patients undergoing hepatectomy. Intraoperatively, photoacoustic tomography was performed on the surface of the resected hepatic specimens (n = 10) under excitation with an 800 nm pulse laser. In 4 hepatocellular carcinoma nodules, photoacoustic imaging identified indocyanine green accumulation in the cancerous tissue. In contrast, in one hepatocellular carcinoma nodule and five adenocarcinoma foci (one intrahepatic cholangiocarcinoma and 4 colorectal liver metastases), photoacoustic imaging delineated indocyanine green accumulation not in the cancerous tissue but rather in the peri-cancerous hepatic parenchyma. Although photoacoustic tomography enabled to visualize spatial distribution of ICG on ultrasonographic images, which was consistent with fluorescence images on cut surfaces of the resected specimens, photoacoustic signals of ICG-containing tissues decreased approximately by 40% even at 4 mm depth from liver surfaces. Photoacoustic tomography using indocyanine green also failed to identify any hepatocellular carcinoma nodules from the body surface of model mice with non-alcoholic steatohepatitis. In conclusion, photoacoustic tomography has a potential to enhance cancer detectability and differential diagnosis by ultrasonographic examinations and intraoperative fluorescence imaging through visualization of stasis of bile-excreting imaging agents in and/or around hepatic tumors. However, further technical advances are needed

  3. An Electromagnetic Sensor for the Autonomous Running of Visually Impaired and Blind Athletes (Part I: The Fixed Infrastructure).

    Science.gov (United States)

    Pieralisi, Marco; Di Mattia, Valentina; Petrini, Valerio; De Leo, Alfredo; Manfredi, Giovanni; Russo, Paola; Scalise, Lorenzo; Cerri, Graziano

    2017-02-14

    Sport is one of the best ways to promote the social integration of people affected by physical disability, because it helps them to increase their self-esteem by facing difficulties and overcoming their disabilities. Nowadays, a large number of sports can be easily played by visually impaired and blind athletes without any special supports, but, there are some disciplines that require the presence of a sighted guide. In this work, the attention will be focused on marathons, during which athletes with visual disorders have to be linked to the sighted guide by means of a non-stretchable elbow tether, with an evident reduction of their performance and autonomy. In this context, this paper presents a fixed electromagnetic infrastructure to equip a standard running racetrack in order to help a blind athlete to safely run without the presence of a sighted guide. The athlete runs inside an invisible hallway, just wearing a light and a comfortable sensor unit. The patented system has been homemade, designed, realized and finally tested by a blind Paralympic marathon champion with encouraging results and interesting suggestions for technical improvements. In this paper (Part I), the transmitting unit, whose main task is to generate the two magnetic fields that delimit the safe hallway, is presented and discussed.

  4. An Electromagnetic Sensor for the Autonomous Running of Visually Impaired and Blind Athletes (Part I: The Fixed Infrastructure

    Directory of Open Access Journals (Sweden)

    Marco Pieralisi

    2017-02-01

    Full Text Available Sport is one of the best ways to promote the social integration of people affected by physical disability, because it helps them to increase their self-esteem by facing difficulties and overcoming their disabilities. Nowadays, a large number of sports can be easily played by visually impaired and blind athletes without any special supports, but, there are some disciplines that require the presence of a sighted guide. In this work, the attention will be focused on marathons, during which athletes with visual disorders have to be linked to the sighted guide by means of a non-stretchable elbow tether, with an evident reduction of their performance and autonomy. In this context, this paper presents a fixed electromagnetic infrastructure to equip a standard running racetrack in order to help a blind athlete to safely run without the presence of a sighted guide. The athlete runs inside an invisible hallway, just wearing a light and a comfortable sensor unit. The patented system has been homemade, designed, realized and finally tested by a blind Paralympic marathon champion with encouraging results and interesting suggestions for technical improvements. In this paper (Part I, the transmitting unit, whose main task is to generate the two magnetic fields that delimit the safe hallway, is presented and discussed.

  5. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  6. Single photon emission computed tomography of the liver

    International Nuclear Information System (INIS)

    Makler, P.T. Jr.

    1988-01-01

    Single photon emission computed tomography (SPECT) of the liver has been introduced in order to improve sensitivity and localization of space-occupying lesions. There have been numerous reports on the usefulness of the technique, as well as extensive analyses of its technical drawbacks. In general, SPECT provides a more accurate estimation of defect size than does conventional planar scintigraphy for cases in which one wishes to evaluate changes in lesion size due to therapy. The presence of a superimposed parenchymal disease, however, remains a major problem, which will only be resolved by a scanning technique that specifically detects the disease process of concern (hot spot imaging) rather than displacement of normal tissue (cold spot imaging)

  7. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  8. [Deep learning and neuronal networks in ophthalmology : Applications in the field of optical coherence tomography].

    Science.gov (United States)

    Treder, M; Eter, N

    2018-04-19

    Deep learning is increasingly becoming the focus of various imaging methods in medicine. Due to the large number of different imaging modalities, ophthalmology is particularly suitable for this field of application. This article gives a general overview on the topic of deep learning and its current applications in the field of optical coherence tomography. For the benefit of the reader it focuses on the clinical rather than the technical aspects.

  9. Computerized tomography used in non-destructive testing of welded pipes

    Energy Technology Data Exchange (ETDEWEB)

    Iovea, M; Rizescu, C; Georgescu, G; Marinescu, A; Chitescu, P; Sava, T; Neagu, M; Avram, D [Institute of Research and Design for Electrical Engineering, ICPE - Electrostatica Splaiul Unirii 313, Sect. 3, R-74204 Bucharest (Romania)

    1997-12-31

    High quality standards in operation of National Power System is ensured by the use of high performance techniques and systems for Non-Destructive Testing (NDT). In recent years a number of new developments of the non-conventional technologies in the field of NDT have been achieved. In our laboratory there have been developed two computerized technologies using {gamma}-ray computed tomography and ultrasonic imaging methods. The standard techniques for imaging from projection data is computerized tomography. The industrial computerized tomography methods consist in the measurement of thin X - or {gamma}-ray beam attenuation when passing through some selected surface of the tested object, along several directions, so that by means of an adequate mathematical algorithm, a map of linear attenuation coefficients for the scanned surface is obtained. In fact, this map gives the density of materials occurring in the surface plane. Computerized tomography equipment, in various constructive versions, are intended for the following applications: (1) NDT in those fields requiring strict control of product quality, as for instance the nuclear energy, military industry, aeronautics, transportation fields, etc., (2) research in field of materials technology, machine engineering, metallurgy, welding, etc. This paper presents the applications of Computerized Tomography in NDT, by showing the results obtained on welded pipes, as well as the facilities offered by this method. In the final part, the paper presents the concept of a mobile tomography system for industrial pipes testing. (author). 2 figs., 7 refs.

  10. Computerized tomography used in non-destructive testing of welded pipes

    International Nuclear Information System (INIS)

    Iovea, M.; Rizescu, C.; Georgescu, G.; Marinescu, A.; Chitescu, P.; Sava, T.; Neagu, M.; Avram, D.

    1996-01-01

    High quality standards in operation of National Power System is ensured by the use of high performance techniques and systems for Non-Destructive Testing (NDT). In recent years a number of new developments of the non-conventional technologies in the field of NDT have been achieved. In our laboratory there have been developed two computerized technologies using γ-ray computed tomography and ultrasonic imaging methods. The standard techniques for imaging from projection data is computerized tomography. The industrial computerized tomography methods consist in the measurement of thin X - or γ-ray beam attenuation when passing through some selected surface of the tested object, along several directions, so that by means of an adequate mathematical algorithm, a map of linear attenuation coefficients for the scanned surface is obtained. In fact, this map gives the density of materials occurring in the surface plane. Computerized tomography equipment, in various constructive versions, are intended for the following applications: 1) NDT in those fields requiring strict control of product quality, as for instance the nuclear energy, military industry, aeronautics, transportation fields, etc., 2) research in field of materials technology, machine engineering, metallurgy, welding, etc. This paper presents the applications of Computerized Tomography in NDT, by showing the results obtained on welded pipes, as well as the facilities offered by this method. In the final part, the paper presents the concept of a mobile tomography system for industrial pipes testing. (author). 2 figs., 7 refs

  11. Independent Technical Review of the C-400 Interim Remedial Project Phase I Results, Paducah, Kentucky

    International Nuclear Information System (INIS)

    Looney, B.; Rossabi, J.; Stewart, L.; Richards, W.

    2010-01-01

    to deployment and a second ITR to evaluate Phase I performance in September 2010. In this report, these ITR efforts are referenced as the '2007 ITR' and the 'current ITR', respectively. The 2007 ITR document (Looney et al., 2007) provided a detailed technical evaluation that remains relevant and this report builds on that analysis. The primary objective of the current ITR is to provide an expedited assessment of the available Phase I data to assist the PGDP team as they develop the lessons learned from Phase I and prepare plans for Phase II.

  12. INDEPENDENT TECHNICAL REVIEW OF THE C-400 INTERIM REMEDIAL PROJECT PHASE I RESULTS, PADUCAH, KENTUCKY

    Energy Technology Data Exchange (ETDEWEB)

    Looney, B.; Rossabi, J.; Stewart,L.; Richards, W.

    2010-10-29

    2007 to assess the C-400 ERH plans prior to deployment and a second ITR to evaluate Phase I performance in September 2010. In this report, these ITR efforts are referenced as the '2007 ITR' and the 'current ITR', respectively. The 2007 ITR document (Looney et al., 2007) provided a detailed technical evaluation that remains relevant and this report builds on that analysis. The primary objective of the current ITR is to provide an expedited assessment of the available Phase I data to assist the PGDP team as they develop the lessons learned from Phase I and prepare plans for Phase II.

  13. A process for integrating public involvement into technical/social programs

    International Nuclear Information System (INIS)

    Wiltshire, S.; Williams, C.

    1994-01-01

    Good technical/social decisions--those that are technically sound and publicly acceptable--result from a planning process that considers consulting the public a basic part of the technical program, as basic as hiring a technical consultant to advise about new ideas in computer modeling. This paper describes a specific process for making public involvement an integral part of decision-making about high-level radioactive waste management, so that important technical, social, environmental, economic, and cultural information and values can be incorporated in a meaningful way in planning and carrying out a high-level waste management program or project. The process for integration must consider: (a) the decision or task for which public interaction is needed; (b) the people who should or will want to participate in the decision or task; (c) the goals or purposes of the communication or interaction--the agency's and the public's; (d) the kinds of information the public needs and that the agency needs in order to understand the relevant technical and social issues; and (e) the types of communication or involvement that best serve to meet the agency's and the public's goals

  14. ATS-6 - Technical aspects of the Health/Education Telecommunications Experiment

    Science.gov (United States)

    Boor, J. L.; Braunstein, J.; Janky, J. M.; Ogden, D.; Potter, J. G.; Harper, E. L.; Volkmer, E.; Whalen, A. A.; Henderson, E.; Hupe, H. H.

    1975-01-01

    An overview is given of the HET experiment on ATS-6. The paper is divided into nine parts, including a technical overview, a preliminary evaluation of the HET demonstration, a review of operations at the Denver uplink terminal, a discussion of remote ground terminals, a review of C-band comprehensive terminals and of S-band comprehensive terminals, and parts devoted to general network operations, technical management and effectiveness of the network, and the site equipment operator.

  15. CT pulmonary angiography of adult pulmonary vascular diseases: Technical considerations and interpretive pitfalls

    International Nuclear Information System (INIS)

    Taslakian, Bedros; Latson, Larry A.; Truong, Mylene T.; Aaltonen, Eric; Shiau, Maria C.; Girvin, Francis; Alpert, Jeffrey B.; Wickstrom, Maj; Ko, Jane P.

    2016-01-01

    Highlights: • CTPA plays a key role in the evaluation of pulmonary vascular diseases. • Improvements in CT technology have improved visualization of pulmonary arteries. • Knowledge of the technical pitfalls is essential for accurate diagnosis. • Dual energy CT imaging enables parenchymal iodine evaluation. • An awareness of the entities affecting the pulmonary arteries is important. - Abstract: Computed tomography pulmonary angiography (CTPA) has become the primary imaging modality for evaluating the pulmonary arteries. Although pulmonary embolism is the primary indication for CTPA, various pulmonary vascular abnormalities can be detected in adults. Knowledge of these disease entities and understanding technical pitfalls that can occur when performing CTPA are essential to enable accurate diagnosis and allow timely management. This review will cover a spectrum of acquired abnormalities including pulmonary embolism due to thrombus and foreign bodies, primary and metastatic tumor involving the pulmonary arteries, pulmonary hypertension, as well as pulmonary artery aneurysms and stenoses. Additionally, methods to overcome technical pitfalls and interventional treatment options will be addressed.

  16. CT pulmonary angiography of adult pulmonary vascular diseases: Technical considerations and interpretive pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: bedros.taslakian@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Latson, Larry A., E-mail: larry.latson@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Truong, Mylene T., E-mail: mtruong@mdanderson.org [Department of Radiology, University of Texas, MD Anderson Cancer Center, TX (United States); Aaltonen, Eric, E-mail: Eric.Aaltonen@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Shiau, Maria C., E-mail: Maria.Shiau@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Girvin, Francis, E-mail: Francis.Girvin@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Alpert, Jeffrey B., E-mail: Jeffrey.Alpert@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Wickstrom, Maj, E-mail: Maj.Wickstrom@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Ko, Jane P., E-mail: Jane.Ko@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States)

    2016-11-15

    Highlights: • CTPA plays a key role in the evaluation of pulmonary vascular diseases. • Improvements in CT technology have improved visualization of pulmonary arteries. • Knowledge of the technical pitfalls is essential for accurate diagnosis. • Dual energy CT imaging enables parenchymal iodine evaluation. • An awareness of the entities affecting the pulmonary arteries is important. - Abstract: Computed tomography pulmonary angiography (CTPA) has become the primary imaging modality for evaluating the pulmonary arteries. Although pulmonary embolism is the primary indication for CTPA, various pulmonary vascular abnormalities can be detected in adults. Knowledge of these disease entities and understanding technical pitfalls that can occur when performing CTPA are essential to enable accurate diagnosis and allow timely management. This review will cover a spectrum of acquired abnormalities including pulmonary embolism due to thrombus and foreign bodies, primary and metastatic tumor involving the pulmonary arteries, pulmonary hypertension, as well as pulmonary artery aneurysms and stenoses. Additionally, methods to overcome technical pitfalls and interventional treatment options will be addressed.

  17. Mineral deposits research in Uruguay. Technical economic part; Investigacion de yacimientos de minerales en el Uruguay. Parte tecnico economica.

    Energy Technology Data Exchange (ETDEWEB)

    Raabe, W

    1959-07-01

    Technical researches, mineralogical and chemical analysis were carried out in Zapucay and Iman deposit located in Uruguay south America, as a result of that, researchers was described the mineral adherences of the deposits.

  18. Apple iTunes music store

    OpenAIRE

    Lenzi, R.; Schmucker, M.; Spadoni, F.

    2003-01-01

    This technical report analyses the Apple iTunes Music Store and its success factors. Besides the technical aspects, user and customer aspects as well as content aspects are considered. Furthermore, iTunes Music Store's impact to online music distribution services is analysed and a short outlook to future music online distribution is given.

  19. NEW STEPS IN SKETCHING MACHINE PARTS

    Directory of Open Access Journals (Sweden)

    Tocariu Liliana

    2009-07-01

    Full Text Available This paper presents new and main steps in sketching machine part, by using the Solid Edge program. The traditional method applied in the technical drawing is appreciably altered in the case of the computer-assisted and modern design. These modifications involve others: e.g., use of classic drawing rule in tool sketching. The author deals with them from three points of view, namely: technical drawing, technical education and advantages.

  20. Preoperative (3-dimensional) computed tomography lung reconstruction before anatomic segmentectomy or lobectomy for stage I non-small cell lung cancer.

    Science.gov (United States)

    Chan, Ernest G; Landreneau, James R; Schuchert, Matthew J; Odell, David D; Gu, Suicheng; Pu, Jiantao; Luketich, James D; Landreneau, Rodney J

    2015-09-01

    Accurate cancer localization and negative resection margins are necessary for successful segmentectomy. In this study, we evaluate a newly developed software package that permits automated segmentation of the pulmonary parenchyma, allowing 3-dimensional assessment of tumor size, location, and estimates of surgical margins. A pilot study using a newly developed 3-dimensional computed tomography analytic software package was performed to retrospectively evaluate preoperative computed tomography images of patients who underwent segmentectomy (n = 36) or lobectomy (n = 15) for stage 1 non-small cell lung cancer. The software accomplishes an automated reconstruction of anatomic pulmonary segments of the lung based on bronchial arborization. Estimates of anticipated surgical margins and pulmonary segmental volume were made on the basis of 3-dimensional reconstruction. Autosegmentation was achieved in 72.7% (32/44) of preoperative computed tomography images with slice thicknesses of 3 mm or less. Reasons for segmentation failure included local severe emphysema or pneumonitis, and lower computed tomography resolution. Tumor segmental localization was achieved in all autosegmented studies. The 3-dimensional computed tomography analysis provided a positive predictive value of 87% in predicting a marginal clearance greater than 1 cm and a 75% positive predictive value in predicting a margin to tumor diameter ratio greater than 1 in relation to the surgical pathology assessment. This preoperative 3-dimensional computed tomography analysis of segmental anatomy can confirm the tumor location within an anatomic segment and aid in predicting surgical margins. This 3-dimensional computed tomography information may assist in the preoperative assessment regarding the suitability of segmentectomy for peripheral lung cancers. Published by Elsevier Inc.